WorldWideScience

Sample records for source separation techniques

  1. Carbon Dioxide Capture and Separation Techniques for Gasification-based Power Generation Point Sources

    Pennline, H.W.; Luebke, D.R.; Jones, K.L.; Morsi, B.I. (Univ. of Pittsburgh, PA); Heintz, Y.J. (Univ. of Pittsburgh, PA); Ilconich, J.B. (Parsons)

    2007-06-01

    The capture/separation step for carbon dioxide (CO2) from large-point sources is a critical one with respect to the technical feasibility and cost of the overall carbon sequestration scenario. For large-point sources, such as those found in power generation, the carbon dioxide capture techniques being investigated by the in-house research area of the National Energy Technology Laboratory possess the potential for improved efficiency and reduced costs as compared to more conventional technologies. The investigated techniques can have wide applications, but the research has focused on capture/separation of carbon dioxide from flue gas (post-combustion from fossil fuel-fired combustors) and from fuel gas (precombustion, such as integrated gasification combined cycle or IGCC). With respect to fuel gas applications, novel concepts are being developed in wet scrubbing with physical absorption; chemical absorption with solid sorbents; and separation by membranes. In one concept, a wet scrubbing technique is being investigated that uses a physical solvent process to remove CO2 from fuel gas of an IGCC system at elevated temperature and pressure. The need to define an ideal solvent has led to the study of the solubility and mass transfer properties of various solvents. Pertaining to another separation technology, fabrication techniques and mechanistic studies for membranes separating CO2 from the fuel gas produced by coal gasification are also being performed. Membranes that consist of CO2-philic ionic liquids encapsulated into a polymeric substrate have been investigated for permeability and selectivity. Finally, dry, regenerable processes based on sorbents are additional techniques for CO2 capture from fuel gas. An overview of these novel techniques is presented along with a research progress status of technologies related to membranes and physical solvents.

  2. Carbon dioxide capture and separation techniques for advanced power generation point sources

    Pennline, H.W.; Luebke, D.R.; Morsi, B.I.; Heintz, Y.J.; Jones, K.L.; Ilconich, J.B.

    2006-09-01

    The capture/separation step for carbon dioxide (CO2) from large-point sources is a critical one with respect to the technical feasibility and cost of the overall carbon sequestration scenario. For large-point sources, such as those found in power generation, the carbon dioxide capture techniques being investigated by the in-house research area of the National Energy Technology Laboratory possess the potential for improved efficiency and costs as compared to more conventional technologies. The investigated techniques can have wide applications, but the research has focused on capture/separation of carbon dioxide from flue gas (postcombustion from fossil fuel-fired combustors) and from fuel gas (precombustion, such as integrated gasification combined cycle – IGCC). With respect to fuel gas applications, novel concepts are being developed in wet scrubbing with physical absorption; chemical absorption with solid sorbents; and separation by membranes. In one concept, a wet scrubbing technique is being investigated that uses a physical solvent process to remove CO2 from fuel gas of an IGCC system at elevated temperature and pressure. The need to define an ideal solvent has led to the study of the solubility and mass transfer properties of various solvents. Fabrication techniques and mechanistic studies for hybrid membranes separating CO2 from the fuel gas produced by coal gasification are also being performed. Membranes that consist of CO2-philic silanes incorporated into an alumina support or ionic liquids encapsulated into a polymeric substrate have been investigated for permeability and selectivity. An overview of two novel techniques is presented along with a research progress status of each technology.

  3. Sources and speciation of heavy metals in municipal solid waste (MSW) and its effect on the separation technique

    Biollaz, S; Ludwig, Ch; Stucki, S [Paul Scherrer Inst. (PSI), Villigen (Switzerland)

    1999-08-01

    A literature search was carried out to determine sources and speciation of heavy metals in MSW. A combination of thermal and mechanical separation techniques is necessary to achieve the required high degrees of metal separation. Metallic goods should be separated mechanically, chemically bound heavy metals by a thermal process. (author) 1 fig., 1 tab., 6 refs.

  4. Modal parameter identification based on combining transmissibility functions and blind source separation techniques

    Araújo, Iván Gómez; Sánchez, Jesús Antonio García; Andersen, Palle

    2018-05-01

    Transmissibility-based operational modal analysis is a recent and alternative approach used to identify the modal parameters of structures under operational conditions. This approach is advantageous compared with traditional operational modal analysis because it does not make any assumptions about the excitation spectrum (i.e., white noise with a flat spectrum). However, common methodologies do not include a procedure to extract closely spaced modes with low signal-to-noise ratios. This issue is relevant when considering that engineering structures generally have closely spaced modes and that their measured responses present high levels of noise. Therefore, to overcome these problems, a new combined method for modal parameter identification is proposed in this work. The proposed method combines blind source separation (BSS) techniques and transmissibility-based methods. Here, BSS techniques were used to recover source signals, and transmissibility-based methods were applied to estimate modal information from the recovered source signals. To achieve this combination, a new method to define a transmissibility function was proposed. The suggested transmissibility function is based on the relationship between the power spectral density (PSD) of mixed signals and the PSD of signals from a single source. The numerical responses of a truss structure with high levels of added noise and very closely spaced modes were processed using the proposed combined method to evaluate its ability to identify modal parameters in these conditions. Colored and white noise excitations were used for the numerical example. The proposed combined method was also used to evaluate the modal parameters of an experimental test on a structure containing closely spaced modes. The results showed that the proposed combined method is capable of identifying very closely spaced modes in the presence of noise and, thus, may be potentially applied to improve the identification of damping ratios.

  5. Instantaneous and Frequency-Warped Signal Processing Techniques for Auditory Source Separation.

    Wang, Avery Li-Chun

    This thesis summarizes several contributions to the areas of signal processing and auditory source separation. The philosophy of Frequency-Warped Signal Processing is introduced as a means for separating the AM and FM contributions to the bandwidth of a complex-valued, frequency-varying sinusoid p (n), transforming it into a signal with slowly-varying parameters. This transformation facilitates the removal of p (n) from an additive mixture while minimizing the amount of damage done to other signal components. The average winding rate of a complex-valued phasor is explored as an estimate of the instantaneous frequency. Theorems are provided showing the robustness of this measure. To implement frequency tracking, a Frequency-Locked Loop algorithm is introduced which uses the complex winding error to update its frequency estimate. The input signal is dynamically demodulated and filtered to extract the envelope. This envelope may then be remodulated to reconstruct the target partial, which may be subtracted from the original signal mixture to yield a new, quickly-adapting form of notch filtering. Enhancements to the basic tracker are made which, under certain conditions, attain the Cramer -Rao bound for the instantaneous frequency estimate. To improve tracking, the novel idea of Harmonic -Locked Loop tracking, using N harmonically constrained trackers, is introduced for tracking signals, such as voices and certain musical instruments. The estimated fundamental frequency is computed from a maximum-likelihood weighting of the N tracking estimates, making it highly robust. The result is that harmonic signals, such as voices, can be isolated from complex mixtures in the presence of other spectrally overlapping signals. Additionally, since phase information is preserved, the resynthesized harmonic signals may be removed from the original mixtures with relatively little damage to the residual signal. Finally, a new methodology is given for designing linear-phase FIR filters

  6. Separation techniques: Chromatography

    Coskun, Ozlem

    2016-01-01

    Chromatography is an important biophysical technique that enables the separation, identification, and purification of the components of a mixture for qualitative and quantitative analysis. Proteins can be purified based on characteristics such as size and shape, total charge, hydrophobic groups present on the surface, and binding capacity with the stationary phase. Four separation techniques based on molecular characteristics and interaction type use mechanisms of ion exchange, surface adsorption, partition, and size exclusion. Other chromatography techniques are based on the stationary bed, including column, thin layer, and paper chromatography. Column chromatography is one of the most common methods of protein purification. PMID:28058406

  7. Immunoassay separation technique

    1977-01-01

    A method for effecting the immunoassay of a multiplicity of samples, each possibly containing an antigen or an antibody to be assayed, is discussed. Each sample is incubated with a solution containing a detectable antigen or antibody to form a multiplicity of mixtures, each mixture containing as components antigen-antibody, non-complexed antigen and non-complexed antibody. At least one of the components of the said mixture is separated by adsorption. There after, quantity of detectable antigen or antibody is detected in one of the non-adsorbed portions of the mixture. An improvement, compared to other techniques, is the continuous and sequential separation of at least one component, which is intended to be separated from each said multiplicity of mixtures

  8. Blind source separation dependent component analysis

    Xiang, Yong; Yang, Zuyuan

    2015-01-01

    This book provides readers a complete and self-contained set of knowledge about dependent source separation, including the latest development in this field. The book gives an overview on blind source separation where three promising blind separation techniques that can tackle mutually correlated sources are presented. The book further focuses on the non-negativity based methods, the time-frequency analysis based methods, and the pre-coding based methods, respectively.

  9. A Hybrid Technique for Blind Separation of Non-Gaussian and Time-Correlated Sources Using a Multicomponent Approach

    Tichavský, Petr; Koldovský, Zbyněk; Yeredor, A.; Gómez-Herrero, G.; Doron, E.

    2008-01-01

    Roč. 19, č. 3 (2008), s. 421-430 ISSN 1045-9227 R&D Projects: GA MŠk 1M0572 Grant - others:GA ČR(CZ) GP102/07/P384 Program:GP Institutional research plan: CEZ:AV0Z10750506 Keywords : blind source separation * independent component analysis Subject RIV: BB - Applied Statistics, Operational Research Impact factor: 3.726, year: 2008

  10. New separation technique. Catalytically functionated separation membrane

    Urgami, Tadashi [Kansai Univ., Osaka (Japan)

    1989-02-01

    This report introduces research examples, showing the fundamental principle of the membrane by separating the catalytically functionated separation membrane into enzyme fixing separation membrane, polymerized metal complex separation membrane and polymer catalyst separation membrane. This membrane can achieve both functions of separation and catalytic reaction simultaneously and has sufficient possibility to combine powerful functions. Enzyme fixing separation membrane is prepared by carrier combination method, bridging method or covering method and the enzyme fixing method with polymerized complex in which enzyme is controlled to prevent the activity lowering as much as possible and enzyme is fixed from an aqueous solution into polymer membrane. This membrane is applied to the continuous manufacturing of invert sugar from cane sugar and adsorption and removing of harmful substances from blood by utilizing both micro-capsuled urease and active carbon. Alginic acid-copper (II) complex membrane is used for the polymerized metal complex membrane and polystyrene sulfonate membrane is used for the polymer catalyst separation membrane. 28 refs., 4 figs., 1 tabs.

  11. Convolutive Blind Source Separation Methods

    Pedersen, Michael Syskind; Larsen, Jan; Kjems, Ulrik

    2008-01-01

    During the past decades, much attention has been given to the separation of mixed sources, in particular for the blind case where both the sources and the mixing process are unknown and only recordings of the mixtures are available. In several situations it is desirable to recover all sources from...... the recorded mixtures, or at least to segregate a particular source. Furthermore, it may be useful to identify the mixing process itself to reveal information about the physical mixing system. In some simple mixing models each recording consists of a sum of differently weighted source signals. However, in many...... real-world applications, such as in acoustics, the mixing process is more complex. In such systems, the mixtures are weighted and delayed, and each source contributes to the sum with multiple delays corresponding to the multiple paths by which an acoustic signal propagates to a microphone...

  12. Particle separations by electrophoretic techniques

    Ballou, N.E.; Petersen, S.L.; Ducatte, G.R.; Remcho, V.T.

    1996-03-01

    A new method for particle separations based on capillary electrophoresis has been developed and characterized. It uniquely separates particles according to their chemical nature. Separations have been demonstrated with chemically modified latex particles and with inorganic oxide and silicate particles. Separations have been shown both experimentally and theoretically to be essentially independent of particle size in the range of about 0.2 μm to 10 μm. The method has been applied to separations of U0 2 particles from environmental particulate material. For this, an integrated method was developed for capillary electrophoretic separation, collection of separated fractions, and determinations of U0 2 and environmental particles in each fraction. Experimental runs with the integrated method on mixtures of UO 2 particles and environmental particulate material demonstrated enrichment factors of 20 for UO 2 particles in respect to environmental particles in the U0 2 containing fractions. This enrichment factor reduces the costs and time for processing particulate samples by the lexan process by a factor of about 20

  13. Removal of micropollutants in source separated sanitation

    Butkovskyi, A.

    2015-01-01

    Source separated sanitation is an innovative sanitation method designed for minimizing use of energy and clean drinking water, and maximizing reuse of water, organics and nutrients from waste water. This approach is based on separate collection and treatment of toilet wastewater (black water) and

  14. Gas separation techniques in nuclear facilities

    Hioki, Hideaki; Morisue, Tetsuo; Ohno, Masayoshi

    1983-01-01

    The literatures concerning the gas separation techniques which are applied to the waste gases generated from nuclear power plants and nuclear fuel reprocessing plants, uranium enrichment and the instrumentation of nuclear facilities are reviewed. The gas permeability and gas separation performance of membranes are discussed in terms of rare gas separation. The investigation into the change of the gas permeability and mechanical properties of membranes with exposure to radiation is reported. The theoretical investigation of the separating cells used for the separation of rare gas and the development of various separating cells are described, and the theoretical and experimental investigations concerning rare gas separation using cascades are described. The application of membrane method to nuclear facilities is explained showing the examples of uranium enrichment, the treatment of waste gases from nuclear reactor buildings and nuclear fuel reprocessing plants, the monitoring of low level β-emitters in stacks, the detection of failed fuels and the detection of water leak in fast breeder reactors. (Yoshitake, I.)

  15. Single channel blind source separation based on ICA feature extraction

    2007-01-01

    A new technique is proposed to solve the blind source separation (BSS) given only a single channel observation. The basis functions and the density of the coefficients of source signals learned by ICA are used as the prior knowledge. Based on the learned prior information the learning rules of single channel BSS are presented by maximizing the joint log likelihood of the mixed sources to obtain source signals from single observation,in which the posterior density of the given measurements is maximized. The experimental results exhibit a successful separation performance for mixtures of speech and music signals.

  16. Removal of micropollutants in source separated sanitation

    Butkovskyi, A.

    2015-01-01

    Source separated sanitation is an innovative sanitation method designed for minimizing use of energy and clean drinking water, and maximizing reuse of water, organics and nutrients from waste water. This approach is based on separate collection and treatment of toilet wastewater (black water) and the rest of the domestic wastewater (grey water). Different characteristics of wastewater streams facilitate recovery of energy, nutrients and fresh water. To ensure agricultural or ecological reuse ...

  17. Blind Source Separation For Ion Mobility Spectra

    Marco, S.; Pomareda, V.; Pardo, A.; Kessler, M.; Goebel, J.; Mueller, G.

    2009-01-01

    Miniaturization is a powerful trend for smart chemical instrumentation in a diversity of applications. It is know that miniaturization in IMS leads to a degradation of the system characteristics. For the present work, we are interested in signal processing solutions to mitigate limitations introduced by limited drift tube length that basically involve a loss of chemical selectivity. While blind source separation techniques (BSS) are popular in other domains, their application for smart chemical instrumentation is limited. However, in some conditions, basically linearity, BSS may fully recover the concentration time evolution and the pure spectra with few underlying hypothesis. This is extremely helpful in conditions where non-expected chemical interferents may appear, or unwanted perturbations may pollute the spectra. SIMPLISMA has been advocated by Harrington et al. in several papers. However, more modern methods of BSS for bilinear decomposition with the restriction of positiveness have appeared in the last decade. In order to explore and compare the performances of those methods a series of experiments were performed.

  18. Blind source separation theory and applications

    Yu, Xianchuan; Xu, Jindong

    2013-01-01

    A systematic exploration of both classic and contemporary algorithms in blind source separation with practical case studies    The book presents an overview of Blind Source Separation, a relatively new signal processing method.  Due to the multidisciplinary nature of the subject, the book has been written so as to appeal to an audience from very different backgrounds. Basic mathematical skills (e.g. on matrix algebra and foundations of probability theory) are essential in order to understand the algorithms, although the book is written in an introductory, accessible style. This book offers

  19. Low Complexity Bayesian Single Channel Source Separation

    Beierholm, Thomas; Pedersen, Brian Dam; Winther, Ole

    2004-01-01

    can be estimated quite precisely using ML-II, but the estimation is quite sensitive to the accuracy of the priors as opposed to the source separation quality for known mixing coefficients, which is quite insensitive to the accuracy of the priors. Finally, we discuss how to improve our approach while...

  20. Joint Matrices Decompositions and Blind Source Separation

    Chabriel, G.; Kleinsteuber, M.; Moreau, E.; Shen, H.; Tichavský, Petr; Yeredor, A.

    2014-01-01

    Roč. 31, č. 3 (2014), s. 34-43 ISSN 1053-5888 R&D Projects: GA ČR GA102/09/1278 Institutional support: RVO:67985556 Keywords : joint matrices decomposition * tensor decomposition * blind source separation Subject RIV: BB - Applied Statistics, Operational Research Impact factor: 5.852, year: 2014 http://library.utia.cas.cz/separaty/2014/SI/tichavsky-0427607.pdf

  1. Point-source inversion techniques

    Langston, Charles A.; Barker, Jeffrey S.; Pavlin, Gregory B.

    1982-11-01

    A variety of approaches for obtaining source parameters from waveform data using moment-tensor or dislocation point source models have been investigated and applied to long-period body and surface waves from several earthquakes. Generalized inversion techniques have been applied to data for long-period teleseismic body waves to obtain the orientation, time function and depth of the 1978 Thessaloniki, Greece, event, of the 1971 San Fernando event, and of several events associated with the 1963 induced seismicity sequence at Kariba, Africa. The generalized inversion technique and a systematic grid testing technique have also been used to place meaningful constraints on mechanisms determined from very sparse data sets; a single station with high-quality three-component waveform data is often sufficient to discriminate faulting type (e.g., strike-slip, etc.). Sparse data sets for several recent California earthquakes, for a small regional event associated with the Koyna, India, reservoir, and for several events at the Kariba reservoir have been investigated in this way. Although linearized inversion techniques using the moment-tensor model are often robust, even for sparse data sets, there are instances where the simplifying assumption of a single point source is inadequate to model the data successfully. Numerical experiments utilizing synthetic data and actual data for the 1971 San Fernando earthquake graphically demonstrate that severe problems may be encountered if source finiteness effects are ignored. These techniques are generally applicable to on-line processing of high-quality digital data, but source complexity and inadequacy of the assumed Green's functions are major problems which are yet to be fully addressed.

  2. Underdetermined Blind Audio Source Separation Using Modal Decomposition

    Abdeldjalil Aïssa-El-Bey

    2007-03-01

    Full Text Available This paper introduces new algorithms for the blind separation of audio sources using modal decomposition. Indeed, audio signals and, in particular, musical signals can be well approximated by a sum of damped sinusoidal (modal components. Based on this representation, we propose a two-step approach consisting of a signal analysis (extraction of the modal components followed by a signal synthesis (grouping of the components belonging to the same source using vector clustering. For the signal analysis, two existing algorithms are considered and compared: namely the EMD (empirical mode decomposition algorithm and a parametric estimation algorithm using ESPRIT technique. A major advantage of the proposed method resides in its validity for both instantaneous and convolutive mixtures and its ability to separate more sources than sensors. Simulation results are given to compare and assess the performance of the proposed algorithms.

  3. Underdetermined Blind Audio Source Separation Using Modal Decomposition

    Aïssa-El-Bey Abdeldjalil

    2007-01-01

    Full Text Available This paper introduces new algorithms for the blind separation of audio sources using modal decomposition. Indeed, audio signals and, in particular, musical signals can be well approximated by a sum of damped sinusoidal (modal components. Based on this representation, we propose a two-step approach consisting of a signal analysis (extraction of the modal components followed by a signal synthesis (grouping of the components belonging to the same source using vector clustering. For the signal analysis, two existing algorithms are considered and compared: namely the EMD (empirical mode decomposition algorithm and a parametric estimation algorithm using ESPRIT technique. A major advantage of the proposed method resides in its validity for both instantaneous and convolutive mixtures and its ability to separate more sources than sensors. Simulation results are given to compare and assess the performance of the proposed algorithms.

  4. Blind source separation problem in GPS time series

    Gualandi, A.; Serpelloni, E.; Belardinelli, M. E.

    2016-04-01

    A critical point in the analysis of ground displacement time series, as those recorded by space geodetic techniques, is the development of data-driven methods that allow the different sources of deformation to be discerned and characterized in the space and time domains. Multivariate statistic includes several approaches that can be considered as a part of data-driven methods. A widely used technique is the principal component analysis (PCA), which allows us to reduce the dimensionality of the data space while maintaining most of the variance of the dataset explained. However, PCA does not perform well in finding the solution to the so-called blind source separation (BSS) problem, i.e., in recovering and separating the original sources that generate the observed data. This is mainly due to the fact that PCA minimizes the misfit calculated using an L2 norm (χ 2), looking for a new Euclidean space where the projected data are uncorrelated. The independent component analysis (ICA) is a popular technique adopted to approach the BSS problem. However, the independence condition is not easy to impose, and it is often necessary to introduce some approximations. To work around this problem, we test the use of a modified variational Bayesian ICA (vbICA) method to recover the multiple sources of ground deformation even in the presence of missing data. The vbICA method models the probability density function (pdf) of each source signal using a mix of Gaussian distributions, allowing for more flexibility in the description of the pdf of the sources with respect to standard ICA, and giving a more reliable estimate of them. Here we present its application to synthetic global positioning system (GPS) position time series, generated by simulating deformation near an active fault, including inter-seismic, co-seismic, and post-seismic signals, plus seasonal signals and noise, and an additional time-dependent volcanic source. We evaluate the ability of the PCA and ICA decomposition

  5. A new electrophoresis technique to separate microsatellite alleles ...

    A new electrophoresis technique to separate microsatellite alleles* ... African Journal of Biotechnology ... with the CEQTM 8000 Genetic Analysis System and ABI 3130xl DNA Sequencer easily separated products and determined allelic size, ...

  6. Energy conversion of source separated packaging; Energiutvinning ur kaellsorterade foerpackningsfraktioner

    Blidholm, O; Wiklund, S E [AaF-Energikonsult (Sweden); Bauer, A C [Energikonsult A. Bauer (Sweden)

    1997-02-01

    The basic idea of this project is to study the possibilities to use source separated combustible material for energy conversion in conventional solid fuel boilers (i.e. not municipal waste incineration plants). The project has been carried out in three phases. During phase 1 and 2 a number of fuel analyses of different fractions were carried out. During phase 3 two combustion tests were carried out; (1) a boiler with grate equipped with cyclone, electrostatic precipitator and flue gas condenser, and (2) a bubbling fluidized bed boiler with electrostatic precipitator and flue gas condenser. During the tests source separated paper and plastic packagings were co-fired with biomass fuels. The mixing rate of packagings was approximately 15%. This study reports the results of phase 3 and the conclusions of the whole project. The technical terms of using packaging as fuel are good. The technique is available for shredding both paper and plastic packaging. The material can be co-fired with biomass. The economical terms of using source separated packaging for energy conversion can be very advantageous, but can also form obstacles. The result is to a high degree guided by such facts as how the fuel is collected, transported, reduced in size and handled at the combustion plant. The results of the combustion tests show that the environmental terms of using source separated packaging for energy conversion are good. The emissions of heavy metals into the atmosphere are very low. The emissions are well below the emission standards for waste incineration plants. 35 figs, 13 tabs, 8 appendices

  7. Source Signals Separation and Reconstruction Following Principal Component Analysis

    WANG Cheng

    2014-02-01

    Full Text Available For separation and reconstruction of source signals from observed signals problem, the physical significance of blind source separation modal and independent component analysis is not very clear, and its solution is not unique. Aiming at these disadvantages, a new linear and instantaneous mixing model and a novel source signals separation reconstruction solving method from observed signals based on principal component analysis (PCA are put forward. Assumption of this new model is statistically unrelated rather than independent of source signals, which is different from the traditional blind source separation model. A one-to-one relationship between linear and instantaneous mixing matrix of new model and linear compound matrix of PCA, and a one-to-one relationship between unrelated source signals and principal components are demonstrated using the concept of linear separation matrix and unrelated of source signals. Based on this theoretical link, source signals separation and reconstruction problem is changed into PCA of observed signals then. The theoretical derivation and numerical simulation results show that, in despite of Gauss measurement noise, wave form and amplitude information of unrelated source signal can be separated and reconstructed by PCA when linear mixing matrix is column orthogonal and normalized; only wave form information of unrelated source signal can be separated and reconstructed by PCA when linear mixing matrix is column orthogonal but not normalized, unrelated source signal cannot be separated and reconstructed by PCA when mixing matrix is not column orthogonal or linear.

  8. Overcomplete Blind Source Separation by Combining ICA and Binary Time-Frequency Masking

    Pedersen, Michael Syskind; Wang, DeLiang; Larsen, Jan

    2005-01-01

    a novel method for over-complete blind source separation. Two powerful source separation techniques have been combined, independent component analysis and binary time-frequency masking. Hereby, it is possible to iteratively extract each speech signal from the mixture. By using merely two microphones we...

  9. Noise source separation of diesel engine by combining binaural sound localization method and blind source separation method

    Yao, Jiachi; Xiang, Yang; Qian, Sichong; Li, Shengyang; Wu, Shaowei

    2017-11-01

    In order to separate and identify the combustion noise and the piston slap noise of a diesel engine, a noise source separation and identification method that combines a binaural sound localization method and blind source separation method is proposed. During a diesel engine noise and vibration test, because a diesel engine has many complex noise sources, a lead covering method was carried out on a diesel engine to isolate other interference noise from the No. 1-5 cylinders. Only the No. 6 cylinder parts were left bare. Two microphones that simulated the human ears were utilized to measure the radiated noise signals 1 m away from the diesel engine. First, a binaural sound localization method was adopted to separate the noise sources that are in different places. Then, for noise sources that are in the same place, a blind source separation method is utilized to further separate and identify the noise sources. Finally, a coherence function method, continuous wavelet time-frequency analysis method, and prior knowledge of the diesel engine are combined to further identify the separation results. The results show that the proposed method can effectively separate and identify the combustion noise and the piston slap noise of a diesel engine. The frequency of the combustion noise and the piston slap noise are respectively concentrated at 4350 Hz and 1988 Hz. Compared with the blind source separation method, the proposed method has superior separation and identification effects, and the separation results have fewer interference components from other noise.

  10. Hydrograph separation techniques in snowmelt-dominated watersheds

    Miller, S.; Miller, S. N.

    2017-12-01

    This study integrates hydrological, geochemical, and isotopic data for a better understanding of different streamflow generation pathways and residence times in a snowmelt-dominated region. A nested watershed design with ten stream gauging sites recording sub-hourly stream stage has been deployed in a snowmelt-dominated region in southeastern Wyoming, heavily impacted by the recent bark beetle epidemic. LiDAR-derived digital elevation models help elucidate effects from topography and watershed metrics. At each stream gauging site, sub-hourly stream water conductivity and temperature data are also recorded. Hydrograph separation is a useful technique for determining different sources of runoff and how volumes from each source vary over time. Following previous methods, diurnal cycles from sub-hourly recorded streamflow and specific conductance data are analyzed and used to separate hydrographs into overland flow and baseflow components, respectively. A final component, vadose-zone flow, is assumed to be the remaining water from the total hydrograph. With access to snowmelt and precipitation data from nearby instruments, runoff coefficients are calculated for the different mechanisms, providing information on watershed response. Catchments are compared to understand how different watershed characteristics translate snowmelt or precipitation events into runoff. Portable autosamplers were deployed at two of the gauging sites for high-frequency analysis of stream water isotopic composition during peak flow to compare methods of hydrograph separation. Sampling rates of one or two hours can detect the diurnal streamflow cycle common during peak snowmelt. Prior research suggests the bark beetle epidemic has had little effect on annual streamflow patterns; however, several results show an earlier shift in the day of year in which peak annual streamflow is observed. The diurnal cycle is likely to comprise a larger percentage of daily streamflow during snowmelt in post

  11. Gradient Flow Convolutive Blind Source Separation

    Pedersen, Michael Syskind; Nielsen, Chinton Møller

    2004-01-01

    Experiments have shown that the performance of instantaneous gradient flow beamforming by Cauwenberghs et al. is reduced significantly in reverberant conditions. By expanding the gradient flow principle to convolutive mixtures, separation in a reverberant environment is possible. By use...... of a circular four microphone array with a radius of 5 mm, and applying convolutive gradient flow instead of just applying instantaneous gradient flow, experimental results show an improvement of up to around 14 dB can be achieved for simulated impulse responses and up to around 10 dB for a hearing aid...

  12. Concepts and Criteria for Blind Quantum Source Separation

    Deville, Alain; Deville, Yannick

    2016-01-01

    Blind Source Separation (BSS) is an active domain of Classical Information Processing. The development of Quantum Information Processing has made possible the appearance of Blind Quantum Source Separation (BQSS). This article discusses some consequences of the existence of the entanglement phenomenon, and of the probabilistic aspect of quantum measurements, upon BQSS solutions. It focuses on a pair of spins initially separately prepared in a pure state, and then with an undesired coupling bet...

  13. Separation of radiation from two sources from their known radiated sum field

    Laitinen, Tommi; Pivnenko, Sergey

    2011-01-01

    This paper presents a technique for complete and exact separation of the radiated fields of two sources (at the same frequency) from the knowledge of their radiated sum field. The two sources can be arbitrary but it must be possible to enclose the sources inside their own non-intersecting minimum...

  14. Underdetermined Blind Source Separation in Echoic Environments Using DESPRIT

    Melia Thomas

    2007-01-01

    Full Text Available The DUET blind source separation algorithm can demix an arbitrary number of speech signals using anechoic mixtures of the signals. DUET however is limited in that it relies upon source signals which are mixed in an anechoic environment and which are sufficiently sparse such that it is assumed that only one source is active at a given time frequency point. The DUET-ESPRIT (DESPRIT blind source separation algorithm extends DUET to situations where sparsely echoic mixtures of an arbitrary number of sources overlap in time frequency. This paper outlines the development of the DESPRIT method and demonstrates its properties through various experiments conducted on synthetic and real world mixtures.

  15. Blind separation of more sources than sensors in convolutive mixtures

    Olsson, Rasmus Kongsgaard; Hansen, Lars Kai

    2006-01-01

    We demonstrate that blind separation of more sources than sensors can be performed based solely on the second order statistics of the observed mixtures. This a generalization of well-known robust algorithms that are suited for equal number of sources and sensors. It is assumed that the sources...

  16. Kernel and divergence techniques in high energy physics separations

    Bouř, Petr; Kůs, Václav; Franc, Jiří

    2017-10-01

    Binary decision trees under the Bayesian decision technique are used for supervised classification of high-dimensional data. We present a great potential of adaptive kernel density estimation as the nested separation method of the supervised binary divergence decision tree. Also, we provide a proof of alternative computing approach for kernel estimates utilizing Fourier transform. Further, we apply our method to Monte Carlo data set from the particle accelerator Tevatron at DØ experiment in Fermilab and provide final top-antitop signal separation results. We have achieved up to 82 % AUC while using the restricted feature selection entering the signal separation procedure.

  17. Comparison of methods for separating vibration sources in rotating machinery

    Klein, Renata

    2017-12-01

    Vibro-acoustic signatures are widely used for diagnostics of rotating machinery. Vibration based automatic diagnostics systems need to achieve a good separation between signals generated by different sources. The separation task may be challenging, since the effects of the different vibration sources often overlap. In particular, there is a need to separate between signals related to the natural frequencies of the structure and signals resulting from the rotating components (signal whitening), as well as a need to separate between signals generated by asynchronous components like bearings and signals generated by cyclo-stationary components like gears. Several methods were proposed to achieve the above separation tasks. The present study compares between some of these methods. The paper also presents a new method for whitening, Adaptive Clutter Separation, as well as a new efficient algorithm for dephase, which separates between asynchronous and cyclo-stationary signals. For whitening the study compares between liftering of the high quefrencies and adaptive clutter separation. For separating between the asynchronous and the cyclo-stationary signals the study compares between liftering in the quefrency domain and dephase. The methods are compared using both simulated signals and real data.

  18. Source separation of household waste: A case study in China

    Zhuang Ying; Wu Songwei; Wang Yunlong; Wu Weixiang; Chen Yingxu

    2008-01-01

    A pilot program concerning source separation of household waste was launched in Hangzhou, capital city of Zhejiang province, China. Detailed investigations on the composition and properties of household waste in the experimental communities revealed that high water content and high percentage of food waste are the main limiting factors in the recovery of recyclables, especially paper from household waste, and the main contributors to the high cost and low efficiency of waste disposal. On the basis of the investigation, a novel source separation method, according to which household waste was classified as food waste, dry waste and harmful waste, was proposed and performed in four selected communities. In addition, a corresponding household waste management system that involves all stakeholders, a recovery system and a mechanical dehydration system for food waste were constituted to promote source separation activity. Performances and the questionnaire survey results showed that the active support and investment of a real estate company and a community residential committee play important roles in enhancing public participation and awareness of the importance of waste source separation. In comparison with the conventional mixed collection and transportation system of household waste, the established source separation and management system is cost-effective. It could be extended to the entire city and used by other cities in China as a source of reference

  19. A particle velocity based method for separating all multi incoherent sound sources

    Winkel, J.C.; Yntema, Doekle Reinder; Druyvesteyn, W.F.; de Bree, H.E.

    2006-01-01

    In this paper we present a method to separate the contributions of different uncorrelated sound sources to the total sound field. When the contribution of each sound source to the total sound field is known, techniques with array-applications like direct sound field measurements or inverse acoustics

  20. Absolute calibration technique for spontaneous fission sources

    Zucker, M.S.; Karpf, E.

    1984-01-01

    An absolute calibration technique for a spontaneously fissioning nuclide (which involves no arbitrary parameters) allows unique determination of the detector efficiency for that nuclide, hence of the fission source strength

  1. Harnessing electro driven separation technique for the separation of selected agrochemicals

    Wan Aini Wan Ibrahim; Alam, S.M. Monjurul; Azli Sulaiman

    2008-01-01

    Electro driven separation techniques offer a different approach to the analysis of complex mixtures than do traditional pressure-driven chromatographic system; it may rely on electrophoresis, the transport of charged species through a medium by an applied field or may rely on electro driven mobile phase to provide a true chromatographic separation. In the current work the potential of an electro driven separation technique viz. Micellar electrokinetic chromatography (MEKC), is harnessed for the separation of selected agrochemicals (organophosphorus pesticides, OPPs) widely used in the agriculture sector in Malaysia. The current study compares the use of MEKC in normal mode (NM) and reverse mode (RM) for the separation of the selected OPPS. This study also highlights the difference in separations produced by performing separations in normal mode-MEKC (NM-MEKC) and reverse mode-MEKC (RM-MEKC) for the selected OPPs. In RM-MEKC, separation is conducted at acidic pH (pH 2.5 in the current work) where the electro osmotic flow (EOF) is weak whereas in NM-MEKC, the separation is carried out under basic pH (9.3 in this work) where the EOF is strong. A reverse migration order of the OPPs was observed under RM-MEKC. Separation under NM-MEKC was found to be superior to those of RM- MEKC. A comparison is also made between separations performed under sweeping-NM-MEKC and sweeping-RM-MEKC. In sweeping, the OPPs are prepared in the same background solution (BGS) minus the micelles and is adjusted to the same conductivity as the BGS. The study showed that NM-MEKC is more sensitive than RM-MEKC but sweeping-RM-MEKC is superior to sweeping-NM-MEKC. However, sweeping-RM-MEKC only separates two of the OPPs in a single run whereas sweeping-NM-MEKC separates four OPPs in a single run. The better choice of separation mode would be sweeping-NM- MEKC for more OPPs separation in a single run. (author)

  2. Solid phase separation technique for use in radioimmunoassays

    Tu, J.I.

    1979-01-01

    A radioimmunoassay procedure, and article of manufacture for carrying out that procedure, are disclosed herein. The solid phase separation technique utilized in the radioimmunoassay of this invention utilizes a test tube, the internal surface of which has been coated with two antibody layers

  3. Extended nonnegative tensor factorisation models for musical sound source separation.

    FitzGerald, Derry; Cranitch, Matt; Coyle, Eugene

    2008-01-01

    Recently, shift-invariant tensor factorisation algorithms have been proposed for the purposes of sound source separation of pitched musical instruments. However, in practice, existing algorithms require the use of log-frequency spectrograms to allow shift invariance in frequency which causes problems when attempting to resynthesise the separated sources. Further, it is difficult to impose harmonicity constraints on the recovered basis functions. This paper proposes a new additive synthesis-based approach which allows the use of linear-frequency spectrograms as well as imposing strict harmonic constraints, resulting in an improved model. Further, these additional constraints allow the addition of a source filter model to the factorisation framework, and an extended model which is capable of separating mixtures of pitched and percussive instruments simultaneously.

  4. Extended Nonnegative Tensor Factorisation Models for Musical Sound Source Separation

    Derry FitzGerald

    2008-01-01

    Full Text Available Recently, shift-invariant tensor factorisation algorithms have been proposed for the purposes of sound source separation of pitched musical instruments. However, in practice, existing algorithms require the use of log-frequency spectrograms to allow shift invariance in frequency which causes problems when attempting to resynthesise the separated sources. Further, it is difficult to impose harmonicity constraints on the recovered basis functions. This paper proposes a new additive synthesis-based approach which allows the use of linear-frequency spectrograms as well as imposing strict harmonic constraints, resulting in an improved model. Further, these additional constraints allow the addition of a source filter model to the factorisation framework, and an extended model which is capable of separating mixtures of pitched and percussive instruments simultaneously.

  5. Carbon footprint of urban source separation for nutrient recovery.

    Kjerstadius, H; Bernstad Saraiva, A; Spångberg, J; Davidsson, Å

    2017-07-15

    Source separation systems for the management of domestic wastewater and food waste has been suggested as more sustainable sanitation systems for urban areas. The present study used an attributional life cycle assessment to investigate the carbon footprint and potential for nutrient recovery of two sanitation systems for a hypothetical urban area in Southern Sweden. The systems represented a typical Swedish conventional system and a possible source separation system with increased nutrient recovery. The assessment included the management chain from household collection, transport, treatment and final return of nutrients to agriculture or disposal of the residuals. The results for carbon footprint and nutrient recovery (phosphorus and nitrogen) concluded that the source separation system could increase nutrient recovery (0.30-0.38 kg P capita -1 year -1 and 3.10-3.28 kg N capita -1 year -1 ), while decreasing the carbon footprint (-24 to -58 kg CO 2 -eq. capita -1 year -1 ), compared to the conventional system. The nutrient recovery was increased by the use of struvite precipitation and ammonium stripping at the wastewater treatment plant. The carbon footprint decreased, mainly due to the increased biogas production, increased replacement of mineral fertilizer in agriculture and less emissions of nitrous oxide from wastewater treatment. In conclusion, the study showed that source separation systems could potentially be used to increase nutrient recovery from urban areas, while decreasing the climate impact. Copyright © 2017 Elsevier Ltd. All rights reserved.

  6. Separation Techniques for Quantification of Radionuclides in Environmental Samples

    Dusan Galanda

    2009-01-01

    Full Text Available The reliable and quantitative measurement of radionuclides is important in order to determine environmental quality and radiation safety, and to monitor regulatory compliance. We examined soil samples from Podunajske Biskupice, near the city of Bratislava in the Slovak Republic, for the presence of several natural (238U, 232Th, 40K and anthropogenic (137Cs, 90Sr, 239Pu, 240Pu, 241Am radionuclides. The area is adjacent to a refinery and hazardous waste processing center, as well as the municipal incinerator plant, and so might possess an unusually high level of ecotoxic metals. We found that the levels of both naturally occurring and anthropogenic radionuclides fell within the expected ranges, indicating that these facilities pose no radiological threat to the local environment. During the course of our analysis, we modified existing techniques in order to allow us to handle the unusually large and complex samples that were needed to determine the levels of 239Pu, 240Pu, and 241Am activity. We also rated three commercial techniques for the separation of 90Sr from aqueous solutions and found that two of them, AnaLig Sr-01 and Empore Extraction Disks, were suitable for the quantitative and reliable separation of 90Sr, while the third, Sr-Spec Resin, was less so. The main criterion in evaluating these methods was the chemical recovery of 90Sr, which was less than we had expected. We also considered speed of separation and additional steps needed to prepare the sample for separation.

  7. Constrained Null Space Component Analysis for Semiblind Source Separation Problem.

    Hwang, Wen-Liang; Lu, Keng-Shih; Ho, Jinn

    2018-02-01

    The blind source separation (BSS) problem extracts unknown sources from observations of their unknown mixtures. A current trend in BSS is the semiblind approach, which incorporates prior information on sources or how the sources are mixed. The constrained independent component analysis (ICA) approach has been studied to impose constraints on the famous ICA framework. We introduced an alternative approach based on the null space component (NCA) framework and referred to the approach as the c-NCA approach. We also presented the c-NCA algorithm that uses signal-dependent semidefinite operators, which is a bilinear mapping, as signatures for operator design in the c-NCA approach. Theoretically, we showed that the source estimation of the c-NCA algorithm converges with a convergence rate dependent on the decay of the sequence, obtained by applying the estimated operators on corresponding sources. The c-NCA can be formulated as a deterministic constrained optimization method, and thus, it can take advantage of solvers developed in optimization society for solving the BSS problem. As examples, we demonstrated electroencephalogram interference rejection problems can be solved by the c-NCA with proximal splitting algorithms by incorporating a sparsity-enforcing separation model and considering the case when reference signals are available.

  8. Planetary Gearbox Fault Detection Using Vibration Separation Techniques

    Lewicki, David G.; LaBerge, Kelsen E.; Ehinger, Ryan T.; Fetty, Jason

    2011-01-01

    Studies were performed to demonstrate the capability to detect planetary gear and bearing faults in helicopter main-rotor transmissions. The work supported the Operations Support and Sustainment (OSST) program with the U.S. Army Aviation Applied Technology Directorate (AATD) and Bell Helicopter Textron. Vibration data from the OH-58C planetary system were collected on a healthy transmission as well as with various seeded-fault components. Planetary fault detection algorithms were used with the collected data to evaluate fault detection effectiveness. Planet gear tooth cracks and spalls were detectable using the vibration separation techniques. Sun gear tooth cracks were not discernibly detectable from the vibration separation process. Sun gear tooth spall defects were detectable. Ring gear tooth cracks were only clearly detectable by accelerometers located near the crack location or directly across from the crack. Enveloping provided an effective method for planet bearing inner- and outer-race spalling fault detection.

  9. Evaluating source separation of plastic waste using conjoint analysis.

    Nakatani, Jun; Aramaki, Toshiya; Hanaki, Keisuke

    2008-11-01

    Using conjoint analysis, we estimated the willingness to pay (WTP) of households for source separation of plastic waste and the improvement of related environmental impacts, the residents' loss of life expectancy (LLE), the landfill capacity, and the CO2 emissions. Unreliable respondents were identified and removed from the sample based on their answers to follow-up questions. It was found that the utility associated with reducing LLE and with the landfill capacity were both well expressed by logarithmic functions, but that residents were indifferent to the level of CO2 emissions even though they approved of CO2 reduction. In addition, residents derived utility from the act of separating plastic waste, irrespective of its environmental impacts; that is, they were willing to practice the separation of plastic waste at home in anticipation of its "invisible effects", such as the improvement of citizens' attitudes toward solid waste issues.

  10. Blind source separation advances in theory, algorithms and applications

    Wang, Wenwu

    2014-01-01

    Blind Source Separation intends to report the new results of the efforts on the study of Blind Source Separation (BSS). The book collects novel research ideas and some training in BSS, independent component analysis (ICA), artificial intelligence and signal processing applications. Furthermore, the research results previously scattered in many journals and conferences worldwide are methodically edited and presented in a unified form. The book is likely to be of interest to university researchers, R&D engineers and graduate students in computer science and electronics who wish to learn the core principles, methods, algorithms, and applications of BSS. Dr. Ganesh R. Naik works at University of Technology, Sydney, Australia; Dr. Wenwu Wang works at University of Surrey, UK.

  11. Source signature estimation from multimode surface waves via mode-separated virtual real source method

    Gao, Lingli; Pan, Yudi

    2018-05-01

    The correct estimation of the seismic source signature is crucial to exploration geophysics. Based on seismic interferometry, the virtual real source (VRS) method provides a model-independent way for source signature estimation. However, when encountering multimode surface waves, which are commonly seen in the shallow seismic survey, strong spurious events appear in seismic interferometric results. These spurious events introduce errors in the virtual-source recordings and reduce the accuracy of the source signature estimated by the VRS method. In order to estimate a correct source signature from multimode surface waves, we propose a mode-separated VRS method. In this method, multimode surface waves are mode separated before seismic interferometry. Virtual-source recordings are then obtained by applying seismic interferometry to each mode individually. Therefore, artefacts caused by cross-mode correlation are excluded in the virtual-source recordings and the estimated source signatures. A synthetic example showed that a correct source signature can be estimated with the proposed method, while strong spurious oscillation occurs in the estimated source signature if we do not apply mode separation first. We also applied the proposed method to a field example, which verified its validity and effectiveness in estimating seismic source signature from shallow seismic shot gathers containing multimode surface waves.

  12. How Many Separable Sources? Model Selection In Independent Components Analysis

    Woods, Roger P.; Hansen, Lars Kai; Strother, Stephen

    2015-01-01

    Unlike mixtures consisting solely of non-Gaussian sources, mixtures including two or more Gaussian components cannot be separated using standard independent components analysis methods that are based on higher order statistics and independent observations. The mixed Independent Components Analysis/Principal Components Analysis (mixed ICA/PCA) model described here accommodates one or more Gaussian components in the independent components analysis model and uses principal components analysis to characterize contributions from this inseparable Gaussian subspace. Information theory can then be used to select from among potential model categories with differing numbers of Gaussian components. Based on simulation studies, the assumptions and approximations underlying the Akaike Information Criterion do not hold in this setting, even with a very large number of observations. Cross-validation is a suitable, though computationally intensive alternative for model selection. Application of the algorithm is illustrated using Fisher's iris data set and Howells' craniometric data set. Mixed ICA/PCA is of potential interest in any field of scientific investigation where the authenticity of blindly separated non-Gaussian sources might otherwise be questionable. Failure of the Akaike Information Criterion in model selection also has relevance in traditional independent components analysis where all sources are assumed non-Gaussian. PMID:25811988

  13. Blind separation of positive sources by globally convergent gradient search.

    Oja, Erkki; Plumbley, Mark

    2004-09-01

    The instantaneous noise-free linear mixing model in independent component analysis is largely a solved problem under the usual assumption of independent nongaussian sources and full column rank mixing matrix. However, with some prior information on the sources, like positivity, new analysis and perhaps simplified solution methods may yet become possible. In this letter, we consider the task of independent component analysis when the independent sources are known to be nonnegative and well grounded, which means that they have a nonzero pdf in the region of zero. It can be shown that in this case, the solution method is basically very simple: an orthogonal rotation of the whitened observation vector into nonnegative outputs will give a positive permutation of the original sources. We propose a cost function whose minimum coincides with nonnegativity and derive the gradient algorithm under the whitening constraint, under which the separating matrix is orthogonal. We further prove that in the Stiefel manifold of orthogonal matrices, the cost function is a Lyapunov function for the matrix gradient flow, implying global convergence. Thus, this algorithm is guaranteed to find the nonnegative well-grounded independent sources. The analysis is complemented by a numerical simulation, which illustrates the algorithm.

  14. Recent advances on ionic liquid uses in separation techniques.

    Berthod, A; Ruiz-Ángel, M J; Carda-Broch, S

    2018-07-20

    The molten organic salts with melting point below 100°C, commonly called ionic liquids (ILs) have found numerous uses in separation sciences due to their exceptional properties as non molecular solvents, namely, a negligible vapor pressure, a high thermal stability, and unique solvating properties due to polarity and their ionic character of molten salts. Other properties, such as viscosity, boiling point, water solubility, and electrochemical window, are adjustable playing with which anion is associated with which cation. This review focuses on recent development of the uses of ILs in separation techniques actualizing our 2008 article (same authors, J. Chromatogr. A, 1184 (2008) 6-18) focusing on alkyl methylimidazolium salts. These developments include the use of ILs in nuclear waste reprocessing, highly thermally stable ILs that allowed for the introduction of polar gas chromatography capillary columns able to work at temperature never seen before (passing 300°C), the use of ILs in liquid chromatography and capillary electrophoresis, and the introduction of tailor-made ILs for mass spectrometry detection of trace anions at the few femtogram level. The recently introduced deep eutectic solvents are not exactly ILs, they are related enough so that their properties and uses in countercurrent chromatography are presented. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Cesium separation using integrated electro-membrane technique

    Fors, Patrik; Lillfors-Pintér, Christina; Widestrand, Henrik; Velin, Anna; Bengtsson, Bernt

    2014-01-01

    Conventional separation technologies such as ion exchange, electro-deionisation and cross flow filtration are not always effective to eliminate nuclides, which are weekly ionised, complexed or hydrated in effluents. Specific nuclide selective absorbers perform well for the treatment of active and contaminated wastewaters but most absorbers generate additional waste while treating high volumes of contaminated water and often show limitations in operating at high flow rates. Electrochemical Ion Exchange (EIX) and EIX in combination with absorbers may offer an alternative solution that overcomes those limitations. This paper reports on the optimization and performance of the integrated technique EIX, for the treatment of low activity effluents that contain cesium and other nuclides. The three-compartment EIX system, which operates with authentic reactor coolant with enhanced nuclide content, indicates high, over 90%, elimination of cesium in a single pass operation mode. With the in-situ and instant ion exchange regeneration, the system successfully reduces the activity from an initial range of 400-2600 Bq/kg to close to detection limit at a velocity of 10-15 cm/min. The applied current density varies between 50-200 mA/cm 2 and the mass balance is close to 100%. During the process, the eliminated cesium and other nuclides are concentrated up to the limits where reverse migration from the concentrated chamber occurs. The concentrate could then be treated with specific absorbents at low flow rates. EIX in combination with cesium-selective ion exchanger CsTreat ® separates the cesium-137 efficiently, but up to now the process does not perform according to EIX principles for the treatment of low grade radioactive wastewaters it rather performs as an irreversible adsorber. The aim with the outcome of the presently ongoing long-term tests is to further support the Best Available Technique Minimizing All Nuclide (BATMAN) projects of Vattenfall NPPs. (author)

  16. Blind Separation of Nonstationary Sources Based on Spatial Time-Frequency Distributions

    Zhang Yimin

    2006-01-01

    Full Text Available Blind source separation (BSS based on spatial time-frequency distributions (STFDs provides improved performance over blind source separation methods based on second-order statistics, when dealing with signals that are localized in the time-frequency (t-f domain. In this paper, we propose the use of STFD matrices for both whitening and recovery of the mixing matrix, which are two stages commonly required in many BSS methods, to provide robust BSS performance to noise. In addition, a simple method is proposed to select the auto- and cross-term regions of time-frequency distribution (TFD. To further improve the BSS performance, t-f grouping techniques are introduced to reduce the number of signals under consideration, and to allow the receiver array to separate more sources than the number of array sensors, provided that the sources have disjoint t-f signatures. With the use of one or more techniques proposed in this paper, improved performance of blind separation of nonstationary signals can be achieved.

  17. Vermicomposting of source-separated human faeces for nutrient recycling.

    Yadav, Kunwar D; Tare, Vinod; Ahammed, M Mansoor

    2010-01-01

    The present study examined the suitability of vermicomposting technology for processing source-separated human faeces. Since the earthworm species Eisenia fetida could not survive in fresh faeces, modification in the physical characteristics of faeces was necessary before earthworms could be introduced to faeces. A preliminary study with six different combinations of faeces, soil and bulking material (vermicompost) in different layers was conducted to find out the best condition for biomass growth and reproduction of earthworms. The results indicated that SVFV combination (soil, vermicompost, faeces and vermicompost - bottom to top layers) was the best for earthworm biomass growth indicating the positive role of soil layer in earthworm biomass growth. Further studies with SVFV and VFV combinations, however, showed that soil layer did not enhance vermicompost production rate. Year-long study conducted with VFV combination to assess the quality and quantity of vermicompost produced showed an average vermicompost production rate of 0.30kg-cast/kg-worm/day. The vermicompost produced was mature as indicated by low dissolved organic carbon (2.4+/-0.43mg/g) and low oxygen uptake rate (0.15+/-0.09mg O(2)/g VS/h). Complete inactivation of total coliforms was noted during the study, which is one of the important objectives of human faeces processing. Results of the study thus indicated the potential of vermicomposting for processing of source-separated human faeces.

  18. Enhanced Landfill Mining case study: Innovative separation techniques

    Cuyvers, Lars; Moerenhout, Tim; Helsen, Stefan; Van de Wiele, Katrien; Behets, Tom; Umans, Luk; Wille, Eddy

    2014-05-01

    In 2011, a corporate vision on Enhanced Landfill Mining (ELFM)1 was approved by the OVAM Board of directors, which resulted in an operational programme over the period 2011-2015. OVAM (Public Waste Agency of Flanders) is the competent authority in charge of waste, Sustainable Materials Management (SMM) and contaminated soil management in Flanders. The introduction of the ELFM concept needs to be related with the concept of SMM and the broader shift to a circular economy. Within the concept of ELFM, landfills are no longer considered to be a final and static situation, but a dynamic part of the materials cycle. The main goal of this research programme is to develop a comprehensive policy on resource management to deal with the issue of former landfills. In order to investigate the opportunities of ELFM, the OVAM is applying a three step approach including mapping, surveying and mining of these former landfills. As a result of the mapping part over 2,000 landfill sites, that will need to be dealt with, were revealed. The valorisation potential of ELFM could be assigned to different goals, according to the R³P-concept : Recycling of Materials, Recovery of Energy, Reclamation of Land and Protection of drinking water supply. . On behalf of the OVAM, ECOREM was assigned to follow-up a pilot case executed on a former landfill, located in Zuienkerke, Flanders. Within this case study some technical tests were carried out on the excavated waste material to investigate the possibilities for a waste to resource conversion. The performance of both on site and off site techniques were evaluated. These testings also contribute to the mapping part of OVAM's research programme on ELFM and reveal more information on the composition of former landfills dating from different era's. In order to recover as many materials as possible, five contractors were assigned to perform separation tests on the bulk material from the Zuienkerke landfill. All used techniques were described

  19. Synthesis of blind source separation algorithms on reconfigurable FPGA platforms

    Du, Hongtao; Qi, Hairong; Szu, Harold H.

    2005-03-01

    Recent advances in intelligence technology have boosted the development of micro- Unmanned Air Vehicles (UAVs) including Sliver Fox, Shadow, and Scan Eagle for various surveillance and reconnaissance applications. These affordable and reusable devices have to fit a series of size, weight, and power constraints. Cameras used on such micro-UAVs are therefore mounted directly at a fixed angle without any motion-compensated gimbals. This mounting scheme has resulted in the so-called jitter effect in which jitter is defined as sub-pixel or small amplitude vibrations. The jitter blur caused by the jitter effect needs to be corrected before any other processing algorithms can be practically applied. Jitter restoration has been solved by various optimization techniques, including Wiener approximation, maximum a-posteriori probability (MAP), etc. However, these algorithms normally assume a spatial-invariant blur model that is not the case with jitter blur. Szu et al. developed a smart real-time algorithm based on auto-regression (AR) with its natural generalization of unsupervised artificial neural network (ANN) learning to achieve restoration accuracy at the sub-pixel level. This algorithm resembles the capability of the human visual system, in which an agreement between the pair of eyes indicates "signal", otherwise, the jitter noise. Using this non-statistical method, for each single pixel, a deterministic blind sources separation (BSS) process can then be carried out independently based on a deterministic minimum of the Helmholtz free energy with a generalization of Shannon's information theory applied to open dynamic systems. From a hardware implementation point of view, the process of jitter restoration of an image using Szu's algorithm can be optimized by pixel-based parallelization. In our previous work, a parallelly structured independent component analysis (ICA) algorithm has been implemented on both Field Programmable Gate Array (FPGA) and Application

  20. Gearbox Fault Diagnosis in a Wind Turbine Using Single Sensor Based Blind Source Separation

    Yuning Qian

    2016-01-01

    Full Text Available This paper presents a single sensor based blind source separation approach, namely, the wavelet-assisted stationary subspace analysis (WSSA, for gearbox fault diagnosis in a wind turbine. Continuous wavelet transform (CWT is used as a preprocessing tool to decompose a single sensor measurement data into a set of wavelet coefficients to meet the multidimensional requirement of the stationary subspace analysis (SSA. The SSA is a blind source separation technique that can separate the multidimensional signals into stationary and nonstationary source components without the need for independency and prior information of the source signals. After that, the separated nonstationary source component with the maximum kurtosis value is analyzed by the enveloping spectral analysis to identify potential fault-related characteristic frequencies. Case studies performed on a wind turbine gearbox test system verify the effectiveness of the WSSA approach and indicate that it outperforms independent component analysis (ICA and empirical mode decomposition (EMD, as well as the spectral-kurtosis-based enveloping, for wind turbine gearbox fault diagnosis.

  1. Blind Source Separation of Event-Related EEG/MEG.

    Metsomaa, Johanna; Sarvas, Jukka; Ilmoniemi, Risto Juhani

    2017-09-01

    Blind source separation (BSS) can be used to decompose complex electroencephalography (EEG) or magnetoencephalography data into simpler components based on statistical assumptions without using a physical model. Applications include brain-computer interfaces, artifact removal, and identifying parallel neural processes. We wish to address the issue of applying BSS to event-related responses, which is challenging because of nonstationary data. We introduce a new BSS approach called momentary-uncorrelated component analysis (MUCA), which is tailored for event-related multitrial data. The method is based on approximate joint diagonalization of multiple covariance matrices estimated from the data at separate latencies. We further show how to extend the methodology for autocovariance matrices and how to apply BSS methods suitable for piecewise stationary data to event-related responses. We compared several BSS approaches by using simulated EEG as well as measured somatosensory and transcranial magnetic stimulation (TMS) evoked EEG. Among the compared methods, MUCA was the most tolerant one to noise, TMS artifacts, and other challenges in the data. With measured somatosensory data, over half of the estimated components were found to be similar by MUCA and independent component analysis. MUCA was also stable when tested with several input datasets. MUCA is based on simple assumptions, and the results suggest that MUCA is robust with nonideal data. Event-related responses and BSS are valuable and popular tools in neuroscience. Correctly designed BSS is an efficient way of identifying artifactual and neural processes from nonstationary event-related data.

  2. Technical feasibility of advanced separation; Faisabilite technique de la separation poussee

    Rostaing, Ch

    2004-07-01

    Advanced separation aims at reducing the amount and toxicity of high-level and long lived radioactive wastes. The Purex process has been retained as a reference way for the recovery of the most radio-toxic elements: neptunium, technetium and iodine. Complementary solvent extraction processes have to be developed for the separation of americium, curium and cesium from the high activity effluent of the spent fuel reprocessing treatment. Researches have been carried out with the aim of demonstrating the scientifical and technical feasibility of advanced separation of minor actinides and long lived fission products from spent fuels. The scientifical feasibility was demonstrated at the end of 2001. The technical feasibility works started in the beginning of 2002. Many results have been obtained which are presented and summarized in this document: approach followed, processes retained for the technical feasibility (An/Ln and Am/Cm separation), processes retained for further validation at the new shielded Purex installation, technical feasibility of Purex adaptation to Np separation, technical feasibility of Diamex (first step: (An+Ln)/other fission products) separation), technical feasibility of Sanex process (second step: An(III)/Ln(III) separation), technical feasibility of Am(III)/Cm(III) separation, cesium separation, iodine separation, technical-economical evaluation, conclusions and perspectives, facilities and apparatuses used for the experiments. (J.S.)

  3. Reverse osmosis brine for phosphorus recovery from source separated urine.

    Tian, Xiujun; Wang, Guotian; Guan, Detian; Li, Jiuyi; Wang, Aimin; Li, Jin; Yu, Zhe; Chen, Yong; Zhang, Zhongguo

    2016-12-01

    Phosphorus (P) recovery from waste streams has recently been recognized as a key step in the sustainable supply of this indispensable and non-renewable resource. The feasibility of using brine from a reverse osmosis (RO) membrane unit treating cooling water as a precipitant for P recovery from source separated urine was evaluated in the present study. P removal efficiency, process parameters and precipitate properties were investigated in batch and continuous flow experiments. More than 90% of P removal was obtained from both undiluted fresh and hydrolyzed urines by mixing with RO brine (1:1, v/v) at a pH over 9.0. Around 2.58 and 1.24 Kg of precipitates could be recovered from 1 m 3 hydrolyzed and fresh urine, respectively, and the precipitated solids contain 8.1-19.0% of P, 10.3-15.2% of Ca, 3.7-5.0% of Mg and 0.1-3.5% of ammonium nitrogen. Satisfactory P removal performance was also achieved in a continuous flow precipitation reactor with a hydraulic retention time of 3-6 h. RO brine could be considered as urinal and toilet flush water despite of a marginally higher precipitation tendency than tap water. This study provides a widely available, low - cost and efficient precipitant for P recovery in urban areas, which will make P recovery from urine more economically attractive. Copyright © 2016 Elsevier Ltd. All rights reserved.

  4. Decentralized modal identification using sparse blind source separation

    Sadhu, A; Hazra, B; Narasimhan, S; Pandey, M D

    2011-01-01

    Popular ambient vibration-based system identification methods process information collected from a dense array of sensors centrally to yield the modal properties. In such methods, the need for a centralized processing unit capable of satisfying large memory and processing demands is unavoidable. With the advent of wireless smart sensor networks, it is now possible to process information locally at the sensor level, instead. The information at the individual sensor level can then be concatenated to obtain the global structure characteristics. A novel decentralized algorithm based on wavelet transforms to infer global structure mode information using measurements obtained using a small group of sensors at a time is proposed in this paper. The focus of the paper is on algorithmic development, while the actual hardware and software implementation is not pursued here. The problem of identification is cast within the framework of under-determined blind source separation invoking transformations of measurements to the time–frequency domain resulting in a sparse representation. The partial mode shape coefficients so identified are then combined to yield complete modal information. The transformations are undertaken using stationary wavelet packet transform (SWPT), yielding a sparse representation in the wavelet domain. Principal component analysis (PCA) is then performed on the resulting wavelet coefficients, yielding the partial mixing matrix coefficients from a few measurement channels at a time. This process is repeated using measurements obtained from multiple sensor groups, and the results so obtained from each group are concatenated to obtain the global modal characteristics of the structure

  5. Decentralized modal identification using sparse blind source separation

    Sadhu, A.; Hazra, B.; Narasimhan, S.; Pandey, M. D.

    2011-12-01

    Popular ambient vibration-based system identification methods process information collected from a dense array of sensors centrally to yield the modal properties. In such methods, the need for a centralized processing unit capable of satisfying large memory and processing demands is unavoidable. With the advent of wireless smart sensor networks, it is now possible to process information locally at the sensor level, instead. The information at the individual sensor level can then be concatenated to obtain the global structure characteristics. A novel decentralized algorithm based on wavelet transforms to infer global structure mode information using measurements obtained using a small group of sensors at a time is proposed in this paper. The focus of the paper is on algorithmic development, while the actual hardware and software implementation is not pursued here. The problem of identification is cast within the framework of under-determined blind source separation invoking transformations of measurements to the time-frequency domain resulting in a sparse representation. The partial mode shape coefficients so identified are then combined to yield complete modal information. The transformations are undertaken using stationary wavelet packet transform (SWPT), yielding a sparse representation in the wavelet domain. Principal component analysis (PCA) is then performed on the resulting wavelet coefficients, yielding the partial mixing matrix coefficients from a few measurement channels at a time. This process is repeated using measurements obtained from multiple sensor groups, and the results so obtained from each group are concatenated to obtain the global modal characteristics of the structure.

  6. Efficient image enhancement using sparse source separation in the Retinex theory

    Yoon, Jongsu; Choi, Jangwon; Choe, Yoonsik

    2017-11-01

    Color constancy is the feature of the human vision system (HVS) that ensures the relative constancy of the perceived color of objects under varying illumination conditions. The Retinex theory of machine vision systems is based on the HVS. Among Retinex algorithms, the physics-based algorithms are efficient; however, they generally do not satisfy the local characteristics of the original Retinex theory because they eliminate global illumination from their optimization. We apply the sparse source separation technique to the Retinex theory to present a physics-based algorithm that satisfies the locality characteristic of the original Retinex theory. Previous Retinex algorithms have limited use in image enhancement because the total variation Retinex results in an overly enhanced image and the sparse source separation Retinex cannot completely restore the original image. In contrast, our proposed method preserves the image edge and can very nearly replicate the original image without any special operation.

  7. Full-Scale Turbofan Engine Noise-Source Separation Using a Four-Signal Method

    Hultgren, Lennart S.; Arechiga, Rene O.

    2016-01-01

    Contributions from the combustor to the overall propulsion noise of civilian transport aircraft are starting to become important due to turbofan design trends and expected advances in mitigation of other noise sources. During on-ground, static-engine acoustic tests, combustor noise is generally sub-dominant to other engine noise sources because of the absence of in-flight effects. Consequently, noise-source separation techniques are needed to extract combustor-noise information from the total noise signature in order to further progress. A novel four-signal source-separation method is applied to data from a static, full-scale engine test and compared to previous methods. The new method is, in a sense, a combination of two- and three-signal techniques and represents an attempt to alleviate some of the weaknesses of each of those approaches. This work is supported by the NASA Advanced Air Vehicles Program, Advanced Air Transport Technology Project, Aircraft Noise Reduction Subproject and the NASA Glenn Faculty Fellowship Program.

  8. The Effects of Environmental Management Systems on Source Separation in the Work and Home Settings

    Chris von Borgstede

    2012-06-01

    Full Text Available Measures that challenge the generation of waste are needed to address the global problem of the increasing volumes of waste that are generated in both private homes and workplaces. Source separation at the workplace is commonly implemented by environmental management systems (EMS. In the present study, the relationship between source separation at work and at home was investigated. A questionnaire that maps psychological and behavioural predictors of source separation was distributed to employees at different workplaces. The results show that respondents with awareness of EMS report higher levels of source separation at work, stronger environmental concern, personal and social norms, and perceive source separation to be less difficult. Furthermore, the results support the notion that after the adoption of EMS at the workplace, source separation at work spills over into source separation in the household. The potential implications for environmental management systems are discussed.

  9. Separation of similar yeast strains by IEF techniques

    Horká, Marie; Růžička, F.; Holá, V.; Šlais, Karel

    2009-01-01

    Roč. 30, č. 12 (2009), s. 2134-2141 ISSN 0173-0835 R&D Projects: GA AV ČR IAAX00310701 Institutional research plan: CEZ:AV0Z40310501 Keywords : biofilm * Candida * lysis Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 3.077, year: 2009

  10. Back-trajectory modeling of high time-resolution air measurement data to separate nearby sources

    Strategies to isolate air pollution contributions from sources is of interest as voluntary or regulatory measures are undertaken to reduce air pollution. When different sources are located in close proximity to one another and have similar emissions, separating source emissions ...

  11. Blind source separation of ex-vivo aorta tissue multispectral images.

    Galeano, July; Perez, Sandra; Montoya, Yonatan; Botina, Deivid; Garzón, Johnson

    2015-05-01

    Blind Source Separation methods (BSS) aim for the decomposition of a given signal in its main components or source signals. Those techniques have been widely used in the literature for the analysis of biomedical images, in order to extract the main components of an organ or tissue under study. The analysis of skin images for the extraction of melanin and hemoglobin is an example of the use of BSS. This paper presents a proof of concept of the use of source separation of ex-vivo aorta tissue multispectral Images. The images are acquired with an interference filter-based imaging system. The images are processed by means of two algorithms: Independent Components analysis and Non-negative Matrix Factorization. In both cases, it is possible to obtain maps that quantify the concentration of the main chromophores present in aortic tissue. Also, the algorithms allow for spectral absorbance of the main tissue components. Those spectral signatures were compared against the theoretical ones by using correlation coefficients. Those coefficients report values close to 0.9, which is a good estimator of the method's performance. Also, correlation coefficients lead to the identification of the concentration maps according to the evaluated chromophore. The results suggest that Multi/hyper-spectral systems together with image processing techniques is a potential tool for the analysis of cardiovascular tissue.

  12. Bayesian mixture models for source separation in MEG

    Calvetti, Daniela; Homa, Laura; Somersalo, Erkki

    2011-01-01

    This paper discusses the problem of imaging electromagnetic brain activity from measurements of the induced magnetic field outside the head. This imaging modality, magnetoencephalography (MEG), is known to be severely ill posed, and in order to obtain useful estimates for the activity map, complementary information needs to be used to regularize the problem. In this paper, a particular emphasis is on finding non-superficial focal sources that induce a magnetic field that may be confused with noise due to external sources and with distributed brain noise. The data are assumed to come from a mixture of a focal source and a spatially distributed possibly virtual source; hence, to differentiate between those two components, the problem is solved within a Bayesian framework, with a mixture model prior encoding the information that different sources may be concurrently active. The mixture model prior combines one density that favors strongly focal sources and another that favors spatially distributed sources, interpreted as clutter in the source estimation. Furthermore, to address the challenge of localizing deep focal sources, a novel depth sounding algorithm is suggested, and it is shown with simulated data that the method is able to distinguish between a signal arising from a deep focal source and a clutter signal. (paper)

  13. Radiochemical separation and their application to neutron activation analysis technique

    Turel, Z.R.

    2013-01-01

    The present paper discusses the development of some new, rapid and selective method for the radiochemical separation and estimation of elements such as, Co(II) 2-3 , Ir(III) 4 , Au(III) 5 , Pt(IV), Pd(II), Os(IV) 6 , Cu(II), Ag(I), Mo(VI), Ni(II), Zn(II), Cd(II), Hg(II), Cs(I), Sb(III), La(III), Sc(III) etc. using various reagents. Various parameters such as pH, time of equilibrium, effect of anions and cations, effect of reagent etc. has been determined employing tracers of the elements under consideration and will be discussed. The method is made highly selective by the use of appropriate masking agent. The stoichiometry of metal reagent is determined by the substoichiometric method. Some examples of multielemental radiochemical separation methods thus developed which have been applied in determining the elements by radiochemical thermal neutron activation analysis will be presented and discussed. The implications of the results on the reference system will also be accounted. Statistical evaluation with reference to accuracy, precision and sensitivity will also be presented

  14. Separation of source and propagation effects at regional distances

    Goldstein, P.; Jarpe, S.; Mayeda, K. [Lawrence Livermore National Lab., CA (United States)] [and others

    1994-12-31

    Improved estimates of the contributions of source and propagation effects to regional seismic signals are needed to explain the performance of existing discriminants and to help develop more robust methods for identifying underground explosions. In this paper, we use close-in, local, and regional estimates of explosion source time functions to remove source effects from regional recordings of the Non-Proliferation Experiment (NPE), a one kiloton chemical explosion in N-tunnel at Rainier Mesa on the Nevada Test Site, and nearby nuclear explosions and earthquakes. Using source corrected regional waveforms, we find that regional Pg and Lg spectra of shallow explosions have significant low frequency ({approximately}1Hz) enhancements when compared to normal depth earthquakes. Data and simulations suggest that such enhancements are most sensitive to source depth, but may also be a function of mechanism, source receiver distance, and regional structure.

  15. Residents’ Household Solid Waste (HSW Source Separation Activity: A Case Study of Suzhou, China

    Hua Zhang

    2014-09-01

    Full Text Available Though the Suzhou government has provided household solid waste (HSW source separation since 2000, the program remains largely ineffective. Between January and March 2014, the authors conducted an intercept survey in five different community groups in Suzhou, and 505 valid surveys were completed. Based on the survey, the authors used an ordered probit regression to study residents’ HSW source separation activities for both Suzhou and for the five community groups. Results showed that 43% of the respondents in Suzhou thought they knew how to source separate HSW, and 29% of them have source separated HSW accurately. The results also found that the current HSW source separation pilot program in Suzhou is valid, as HSW source separation facilities and residents’ separation behavior both became better and better along with the program implementation. The main determinants of residents’ HSW source separation behavior are residents’ age, HSW source separation facilities and government preferential policies. The accessibility to waste management service is particularly important. Attitudes and willingness do not have significant impacts on residents’ HSW source separation behavior.

  16. Source Separation of Heartbeat Sounds for Effective E-Auscultation

    Geethu, R. S.; Krishnakumar, M.; Pramod, K. V.; George, Sudhish N.

    2016-03-01

    This paper proposes a cost effective solution for improving the effectiveness of e-auscultation. Auscultation is the most difficult skill for a doctor, since it can be acquired only through experience. The heart sound mixtures are captured by placing the four numbers of sensors at appropriate auscultation area in the body. These sound mixtures are separated to its relevant components by a statistical method independent component analysis. The separated heartbeat sounds can be further processed or can be stored for future reference. This idea can be used for making a low cost, easy to use portable instrument which will be beneficial to people living in remote areas and are unable to take the advantage of advanced diagnosis methods.

  17. Source separation on hyperspectral cube applied to dermatology

    Mitra, J.; Jolivot, R.; Vabres, P.; Marzani, F. S.

    2010-03-01

    This paper proposes a method of quantification of the components underlying the human skin that are supposed to be responsible for the effective reflectance spectrum of the skin over the visible wavelength. The method is based on independent component analysis assuming that the epidermal melanin and the dermal haemoglobin absorbance spectra are independent of each other. The method extracts the source spectra that correspond to the ideal absorbance spectra of melanin and haemoglobin. The noisy melanin spectrum is fixed using a polynomial fit and the quantifications associated with it are reestimated. The results produce feasible quantifications of each source component in the examined skin patch.

  18. Inorganic membranes for separative techniques: from uranium isotope separation to non-nuclear fields

    Charpin, J.; Rigny, P.

    1989-01-01

    Uranium enrichment leads to the development of inorganic porous barriers - either ceramic or metallic. A wide range of these products had considerable potential for the improvement of filtration techniques in liquid media (ultrafiltration and microfiltration). This is how a new generation of inorganic membranes was created reputed for their performance and especially for their lifetime and their behaviour (mechanical and temperature stability, corrosion resistance). These membranes now have a respectable position in applications in the agro-food biotechnology industries, to give only two examples. Before the non-nuclear applications of inorganic membranes are presented, their success in the nuclear power industry are pointed out

  19. IMPROVEMENT OF BIOFUEL ETHANOL RECOVERY USING THE PERVAPORATION SEPARATION TECHNIQUE

    Nilufer Durmaz Hilmioglu [Kocaeli University Chemical Engineering Department Veziroglu Campus, Kocaeli (Turkey)

    2008-09-30

    The climatic impact of carbon dioxide emissions from the burning of fossil fuels have become a major problem. The production of renewable biofuels from biomass has received increasing attention. Because of the economic and environmental benefits of fuel ethanol's use it is considered one of the most important renewable fuels. In ethanol fermentations inhibition of the microorganism by ethanol limits the amount of substrate in the feed that can be converted. In a process high feed concentrations are desirable to minimize the flows. Such high feed concentrations can be realized in integrated processes in which ethanol is recovered by pervaporation from the fermentation broth as it is formed. The hybrid process is an attractive process to increase ethanol production economics and to decrease environmental pollution. The separaiton of alcohol from mixtures with ethanol produced by fermentation is usually carried out by distillation and the energy consumption is very high when azeotropic concentration is reached, which corresponds to 5% water in ethanol/water mixture. The pervaporation process provides an economical alternative to the existing distillation technique. A continous recovery of alcohol could be achieved by using the pervaporation process during fermentation, making the process more energy efficient. In this work, for the purposes of membrane material development for pervaporation; zeolite filled and unfilled cellulose acetate membranes were prepared. Zeolite types were 4A, 13X. The effect of incorporation of nano-sized zeolites prepared in a colloidal form in membranes was also investigated. From the sorption tests it is concluded that, ethanol/water azeotropy can be breaked by pervaporation.

  20. Les techniques de séparation de gaz par membranes Gas Separation Techniques by Membranes

    Avrillon R.

    2006-11-01

    , great flexibility of implementation because of the modular nature and the possibility of the great automation of permeators, and the moderate size and weight of the installation. Limitations are linked to the difficulty in obtaining both good purity and high yield for a product with a membrane surface area that is economically acceptable. Likewise, the pressure drop undergone by the permeate may be a disadvantage. Gas permeation can be associated with other separation techniques such as pressure swing adsorption, freeze drying or absorption. The principal applications of gas permeation at present are as follows: (a Hydrogen recovery from drain effluents from ammonia synthesis units in which hydrogen has to be separated from nitrogen, methane and argon. (b Hydrogen recovery from refinery gas in which the hydrogen is mixed with hydrocarbons, hydrogen sulfide and water vapor. (c Adjustment of the hydrogen/carbon-monoxide ratio of alcohol synthesis gas. (d Air fractionating from the production of blanketing nitrogen. (e Natural-gas dehydration and sweetening with a view to its transportation by pipeline, especially in offshore production. Table 5 lists the leading membrane suppliers and their fields of activity.

  1. Source Separation via Spectral Masking for Speech Recognition Systems

    Gustavo Fernandes Rodrigues

    2012-12-01

    Full Text Available In this paper we present an insight into the use of spectral masking techniques in time-frequency domain, as a preprocessing step for the speech signal recognition. Speech recognition systems have their performance negatively affected in noisy environments or in the presence of other speech signals. The limits of these masking techniques for different levels of the signal-to-noise ratio are discussed. We show the robustness of the spectral masking techniques against four types of noise: white, pink, brown and human speech noise (bubble noise. The main contribution of this work is to analyze the performance limits of recognition systems  using spectral masking. We obtain an increase of 18% on the speech hit rate, when the speech signals were corrupted by other speech signals or bubble noise, with different signal-to-noise ratio of approximately 1, 10 and 20 dB. On the other hand, applying the ideal binary masks to mixtures corrupted by white, pink and brown noise, results an average growth of 9% on the speech hit rate, with the same different signal-to-noise ratio. The experimental results suggest that the masking spectral techniques are more suitable for the case when it is applied a bubble noise, which is produced by human speech, than for the case of applying white, pink and brown noise.

  2. Atmospheric pressure surface sampling/ionization techniques for direct coupling of planar separations with mass spectrometry.

    Pasilis, Sofie P; Van Berkel, Gary J

    2010-06-18

    Planar separations, which include thin layer chromatography and gel electrophoresis, are in widespread use as important and powerful tools for conducting separations of complex mixtures. To increase the utility of planar separations, new methods are needed that allow in situ characterization of the individual components of the separated mixtures. A large number of atmospheric pressure surface sampling and ionization techniques for use with mass spectrometry have emerged in the past several years, and several have been investigated as a means for mass spectrometric read-out of planar separations. In this article, we review the atmospheric pressure surface sampling and ionization techniques that have been used for the read-out of planar separation media. For each technique, we briefly explain the operational basics and discuss the analyte type for which it is appropriate and some specific applications from the literature. Copyright (c) 2010 Elsevier B.V. All rights reserved.

  3. System identification through nonstationary data using Time-Frequency Blind Source Separation

    Guo, Yanlin; Kareem, Ahsan

    2016-06-01

    Classical output-only system identification (SI) methods are based on the assumption of stationarity of the system response. However, measured response of buildings and bridges is usually non-stationary due to strong winds (e.g. typhoon, and thunder storm etc.), earthquakes and time-varying vehicle motions. Accordingly, the response data may have time-varying frequency contents and/or overlapping of modal frequencies due to non-stationary colored excitation. This renders traditional methods problematic for modal separation and identification. To address these challenges, a new SI technique based on Time-Frequency Blind Source Separation (TFBSS) is proposed. By selectively utilizing "effective" information in local regions of the time-frequency plane, where only one mode contributes to energy, the proposed technique can successfully identify mode shapes and recover modal responses from the non-stationary response where the traditional SI methods often encounter difficulties. This technique can also handle response with closely spaced modes which is a well-known challenge for the identification of large-scale structures. Based on the separated modal responses, frequency and damping can be easily identified using SI methods based on a single degree of freedom (SDOF) system. In addition to the exclusive advantage of handling non-stationary data and closely spaced modes, the proposed technique also benefits from the absence of the end effects and low sensitivity to noise in modal separation. The efficacy of the proposed technique is demonstrated using several simulation based studies, and compared to the popular Second-Order Blind Identification (SOBI) scheme. It is also noted that even some non-stationary response data can be analyzed by the stationary method SOBI. This paper also delineates non-stationary cases where SOBI and the proposed scheme perform comparably and highlights cases where the proposed approach is more advantageous. Finally, the performance of the

  4. Separation of non-stationary multi-source sound field based on the interpolated time-domain equivalent source method

    Bi, Chuan-Xing; Geng, Lin; Zhang, Xiao-Zheng

    2016-05-01

    In the sound field with multiple non-stationary sources, the measured pressure is the sum of the pressures generated by all sources, and thus cannot be used directly for studying the vibration and sound radiation characteristics of every source alone. This paper proposes a separation model based on the interpolated time-domain equivalent source method (ITDESM) to separate the pressure field belonging to every source from the non-stationary multi-source sound field. In the proposed method, ITDESM is first extended to establish the relationship between the mixed time-dependent pressure and all the equivalent sources distributed on every source with known location and geometry information, and all the equivalent source strengths at each time step are solved by an iterative solving process; then, the corresponding equivalent source strengths of one interested source are used to calculate the pressure field generated by that source alone. Numerical simulation of two baffled circular pistons demonstrates that the proposed method can be effective in separating the non-stationary pressure generated by every source alone in both time and space domains. An experiment with two speakers in a semi-anechoic chamber further evidences the effectiveness of the proposed method.

  5. How Many Separable Sources? Model Selection In Independent Components Analysis

    Woods, Roger P.; Hansen, Lars Kai; Strother, Stephen

    2015-01-01

    among potential model categories with differing numbers of Gaussian components. Based on simulation studies, the assumptions and approximations underlying the Akaike Information Criterion do not hold in this setting, even with a very large number of observations. Cross-validation is a suitable, though....../Principal Components Analysis (mixed ICA/PCA) model described here accommodates one or more Gaussian components in the independent components analysis model and uses principal components analysis to characterize contributions from this inseparable Gaussian subspace. Information theory can then be used to select from...... might otherwise be questionable. Failure of the Akaike Information Criterion in model selection also has relevance in traditional independent components analysis where all sources are assumed non-Gaussian....

  6. Magnetic separation techniques in sample preparation for biological analysis: a review.

    He, Jincan; Huang, Meiying; Wang, Dongmei; Zhang, Zhuomin; Li, Gongke

    2014-12-01

    Sample preparation is a fundamental and essential step in almost all the analytical procedures, especially for the analysis of complex samples like biological and environmental samples. In past decades, with advantages of superparamagnetic property, good biocompatibility and high binding capacity, functionalized magnetic materials have been widely applied in various processes of sample preparation for biological analysis. In this paper, the recent advancements of magnetic separation techniques based on magnetic materials in the field of sample preparation for biological analysis were reviewed. The strategy of magnetic separation techniques was summarized. The synthesis, stabilization and bio-functionalization of magnetic nanoparticles were reviewed in detail. Characterization of magnetic materials was also summarized. Moreover, the applications of magnetic separation techniques for the enrichment of protein, nucleic acid, cell, bioactive compound and immobilization of enzyme were described. Finally, the existed problems and possible trends of magnetic separation techniques for biological analysis in the future were proposed. Copyright © 2014 Elsevier B.V. All rights reserved.

  7. Separation of phytochemicals from Helichrysum italicum: An analysis of different isolation techniques and biological activity of prepared extracts.

    Maksimovic, Svetolik; Tadic, Vanja; Skala, Dejan; Zizovic, Irena

    2017-06-01

    Helichrysum italicum presents a valuable source of natural bioactive compounds. In this work, a literature review of terpenes, phenolic compounds, and other less common phytochemicals from H. italicum with regard to application of different separation methods is presented. Data including extraction/separation methods and experimental conditions applied, obtained yields, number of identified compounds, content of different compound groups, and analytical techniques applied are shown as corresponding tables. Numerous biological activities of both isolates and individual compounds are emphasized. In addition, the data reported are discussed, and the directions for further investigations are proposed. Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. Empirical Study on Factors Influencing Residents' Behavior of Separating Household Wastes at Source

    Qu Ying; Zhu Qinghua; Murray Haight

    2007-01-01

    Source separation is the basic premise for making effective use of household wastes. In eight cities of China, however, several pilot projects of source separation finally failed because of the poor participation rate of residents. In order to solve this problem, identifying those factors that influence residents' behavior of source separation becomes crucial. By means of questionnaire survey, we conducted descriptive analysis and exploratory factor analysis. The results show that trouble-feeling, moral notion, environment protection, public education, environment value and knowledge deficiency are the main factors that play an important role for residents in deciding to separate their household wastes. Also, according to the contribution percentage of the six main factors to the total behavior of source separation, their influencing power is analyzed, which will provide suggestions on household waste management for policy makers and decision makers in China.

  9. Single-channel source separation using non-negative matrix factorization

    Schmidt, Mikkel Nørgaard

    -determined and its solution relies on making appropriate assumptions concerning the sources. This dissertation is concerned with model-based probabilistic single-channel source separation based on non-negative matrix factorization, and consists of two parts: i) three introductory chapters and ii) five published...... papers. The first part introduces the single-channel source separation problem as well as non-negative matrix factorization and provides a comprehensive review of existing approaches, applications, and practical algorithms. This serves to provide context for the second part, the published papers......, in which a number of methods for single-channel source separation based on non-negative matrix factorization are presented. In the papers, the methods are applied to separating audio signals such as speech and musical instruments and separating different types of tissue in chemical shift imaging....

  10. Blind Source Separation Based on Covariance Ratio and Artificial Bee Colony Algorithm

    Lei Chen

    2014-01-01

    Full Text Available The computation amount in blind source separation based on bioinspired intelligence optimization is high. In order to solve this problem, we propose an effective blind source separation algorithm based on the artificial bee colony algorithm. In the proposed algorithm, the covariance ratio of the signals is utilized as the objective function and the artificial bee colony algorithm is used to solve it. The source signal component which is separated out, is then wiped off from mixtures using the deflation method. All the source signals can be recovered successfully by repeating the separation process. Simulation experiments demonstrate that significant improvement of the computation amount and the quality of signal separation is achieved by the proposed algorithm when compared to previous algorithms.

  11. A robust physiology-based source separation method for QRS detection in low amplitude fetal ECG recordings

    Vullings, R; Bergmans, J W M; Peters, C H L; Hermans, M J M; Wijn, P F F; Oei, S G

    2010-01-01

    The use of the non-invasively obtained fetal electrocardiogram (ECG) in fetal monitoring is complicated by the low signal-to-noise ratio (SNR) of ECG signals. Even after removal of the predominant interference (i.e. the maternal ECG), the SNR is generally too low for medical diagnostics, and hence additional signal processing is still required. To this end, several methods for exploiting the spatial correlation of multi-channel fetal ECG recordings from the maternal abdomen have been proposed in the literature, of which principal component analysis (PCA) and independent component analysis (ICA) are the most prominent. Both PCA and ICA, however, suffer from the drawback that they are blind source separation (BSS) techniques and as such suboptimum in that they do not consider a priori knowledge on the abdominal electrode configuration and fetal heart activity. In this paper we propose a source separation technique that is based on the physiology of the fetal heart and on the knowledge of the electrode configuration. This technique operates by calculating the spatial fetal vectorcardiogram (VCG) and approximating the VCG for several overlayed heartbeats by an ellipse. By subsequently projecting the VCG onto the long axis of this ellipse, a source signal of the fetal ECG can be obtained. To evaluate the developed technique, its performance is compared to that of both PCA and ICA and to that of augmented versions of these techniques (aPCA and aICA; PCA and ICA applied on preprocessed signals) in generating a fetal ECG source signal with enhanced SNR that can be used to detect fetal QRS complexes. The evaluation shows that the developed source separation technique performs slightly better than aPCA and aICA and outperforms PCA and ICA and has the main advantage that, with respect to aPCA/PCA and aICA/ICA, it performs more robustly. This advantage renders it favorable for employment in automated, real-time fetal monitoring applications

  12. Electromigration techniques for Ge(II) and Ge(IV) separation in germanium thio compounds

    Facetti, J F; Vallejos, A [Asuncion Naciona Univ. (Paraguay). Inst. de Ciencias

    1971-01-01

    Using H.V. electromigration techniques, a good separation of the Ge(II) and Ge(IV) was achieved. The procedure was carried out in alkaline medium. And the final position of the separated species was established by, either neutron activation of the papa strips or chromatic reactions.

  13. Electromigration techniques for Ge(II) and Ge(IV) separation in germanium thio compounds

    Facetti, J.F.; Vallejos, A.

    1971-01-01

    Using H.V. electromigration techniques, a good separation of the Ge(II) and Ge(IV) was achieved. The procedure was carried out in alkaline medium. And the final position of the separated species was established by, either neutron activation of the papa strips or chromatic reactions

  14. Sorption technique of separation of thallium-201 from proton-irradiated thallium

    Deptula, Cz.; Zajtseva, N.G.; Mikolaevskij, S.; Khalkin, V.A.

    1989-01-01

    A sorption technique is developed for radiochemical separation of thallium-201 from proton-irradiated targets of metallic thallium. The technique consists in separation of 201 Pb and 201 Tl in the column with ammonium 12-molybdophosphate fixed in the matrix of porous Teflon (AMP-sorbent). The chemical yield of radiothallium is 98 %, the duration of chemical procedures is 2.5-3 hours. 21 refs.; 1 fig.; 1 tab

  15. Automation of neutral beam source conditioning with artificial intelligence techniques

    Johnson, R.R.; Canales, T.W.; Lager, D.L.

    1985-01-01

    This paper describes a system that automates neutral beam source conditioning. The system achieves this with artificial intelligence techniques. The architecture of the system is presented followed by a description of its performance

  16. Automation of neutral beam source conditioning with artificial intelligence techniques

    Johnson, R.R.; Canales, T.; Lager, D.

    1986-01-01

    This paper describes a system that automates neutral beam source conditioning. The system achieves this with artificial intelligence techniques. The architecture of the system is presented followed by a description of its performance

  17. A Separation Algorithm for Sources with Temporal Structure Only Using Second-order Statistics

    J.G. Wang

    2013-09-01

    Full Text Available Unlike conventional blind source separation (BSS deals with independent identically distributed (i.i.d. sources, this paper addresses the separation from mixtures of sources with temporal structure, such as linear autocorrelations. Many sequential extraction algorithms have been reported, resulting in inevitable cumulated errors introduced by the deflation scheme. We propose a robust separation algorithm to recover original sources simultaneously, through a joint diagonalizer of several average delayed covariance matrices at positions of the optimal time delay and its integers. The proposed algorithm is computationally simple and efficient, since it is based on the second-order statistics only. Extensive simulation results confirm the validity and high performance of the algorithm. Compared with related extraction algorithms, its separation signal-to-noise rate for a desired source can reach 20dB higher, and it seems rather insensitive to the estimation error of the time delay.

  18. An incentive-based source separation model for sustainable municipal solid waste management in China.

    Xu, Wanying; Zhou, Chuanbin; Lan, Yajun; Jin, Jiasheng; Cao, Aixin

    2015-05-01

    Municipal solid waste (MSW) management (MSWM) is most important and challenging in large urban communities. Sound community-based waste management systems normally include waste reduction and material recycling elements, often entailing the separation of recyclable materials by the residents. To increase the efficiency of source separation and recycling, an incentive-based source separation model was designed and this model was tested in 76 households in Guiyang, a city of almost three million people in southwest China. This model embraced the concepts of rewarding households for sorting organic waste, government funds for waste reduction, and introducing small recycling enterprises for promoting source separation. Results show that after one year of operation, the waste reduction rate was 87.3%, and the comprehensive net benefit under the incentive-based source separation model increased by 18.3 CNY tonne(-1) (2.4 Euros tonne(-1)), compared to that under the normal model. The stakeholder analysis (SA) shows that the centralized MSW disposal enterprises had minimum interest and may oppose the start-up of a new recycling system, while small recycling enterprises had a primary interest in promoting the incentive-based source separation model, but they had the least ability to make any change to the current recycling system. The strategies for promoting this incentive-based source separation model are also discussed in this study. © The Author(s) 2015.

  19. COMPARISON OF RECURSIVE ESTIMATION TECHNIQUES FOR POSITION TRACKING RADIOACTIVE SOURCES

    Muske, K.; Howse, J.

    2000-01-01

    This paper compares the performance of recursive state estimation techniques for tracking the physical location of a radioactive source within a room based on radiation measurements obtained from a series of detectors at fixed locations. Specifically, the extended Kalman filter, algebraic observer, and nonlinear least squares techniques are investigated. The results of this study indicate that recursive least squares estimation significantly outperforms the other techniques due to the severe model nonlinearity

  20. Integrality and separability of multitouch interaction techniques in 3D manipulation tasks.

    Martinet, Anthony; Casiez, Géry; Grisoni, Laurent

    2012-03-01

    Multitouch displays represent a promising technology for the display and manipulation of data. While the manipulation of 2D data has been widely explored, 3D manipulation with multitouch displays remains largely unexplored. Based on an analysis of the integration and separation of degrees of freedom, we propose a taxonomy for 3D manipulation techniques with multitouch displays. Using that taxonomy, we introduce Depth-Separated Screen-Space (DS3), a new 3D manipulation technique based on the separation of translation and rotation. In a controlled experiment, we compared DS3 with Sticky Tools and Screen-Space. Results show that separating the control of translation and rotation significantly affects performance for 3D manipulation, with DS3 performing faster than the two other techniques.

  1. Stationary plasma source of heavy ions for imitating research at the separator

    Yuferov, V.B.; Sharyj, S.V.; Seroshtanov, V.A.

    2008-01-01

    The imitation gas mix choice for experimenting on the demonstration imitation separator have been grounded. The construction of plasma source is changed. The research of operating conditions and contrastive analysis of received characteristics have been carry out

  2. Separation Techniques for Uranium and Plutonium at Trace Levels for the Thermal Ionization Mass Spectrometric Determination

    Suh, M. Y.; Han, S. H.; Kim, J. G.; Park, Y. J.; Kim, W. H.

    2005-12-01

    This report describes the state of the art and the progress of the chemical separation and purification techniques required for the thermal ionization mass spectrometric determination of uranium and plutonium in environmental samples at trace or ultratrace levels. Various techniques, such as precipitation, solvent extraction, extraction chromatography, and ion exchange chromatography, for separation of uranium and plutonium were evaluated. Sample preparation methods and dissolution techniques for environmental samples were also discussed. Especially, both extraction chromatographic and anion exchange chromatographic procedures for uranium and plutonium in environmental samples, such as soil, sediment, plant, seawater, urine, and bone ash were reviewed in detail in order to propose some suitable methods for the separation and purification of uranium and plutonium from the safeguards environmental or swipe samples. A survey of the IAEA strengthened safeguards system, the clean room facility of IAEA's NWAL(Network of Analytical Laboratories), and the analytical techniques for safeguards environmental samples was also discussed here

  3. Separation Techniques for Uranium and Plutonium at Trace Levels for the Thermal Ionization Mass Spectrometric Determination

    Suh, M. Y.; Han, S. H.; Kim, J. G.; Park, Y. J.; Kim, W. H

    2005-12-15

    This report describes the state of the art and the progress of the chemical separation and purification techniques required for the thermal ionization mass spectrometric determination of uranium and plutonium in environmental samples at trace or ultratrace levels. Various techniques, such as precipitation, solvent extraction, extraction chromatography, and ion exchange chromatography, for separation of uranium and plutonium were evaluated. Sample preparation methods and dissolution techniques for environmental samples were also discussed. Especially, both extraction chromatographic and anion exchange chromatographic procedures for uranium and plutonium in environmental samples, such as soil, sediment, plant, seawater, urine, and bone ash were reviewed in detail in order to propose some suitable methods for the separation and purification of uranium and plutonium from the safeguards environmental or swipe samples. A survey of the IAEA strengthened safeguards system, the clean room facility of IAEA's NWAL(Network of Analytical Laboratories), and the analytical techniques for safeguards environmental samples was also discussed here.

  4. Separation of mycotoxin-containing sources in grain dust and determination of their mycotoxin potential.

    Palmgren, M S; Lee, L S

    1986-01-01

    Two distinct reservoirs of mycotoxins exist in fungal-infected cereal grains--the fungal spores and the spore-free mycelium-substrate matrix. Many fungal spores are of respirable size and the mycelium-substrate matrix can be pulverized to form particles of respirable size during routine handling of grain. In order to determine the contribution of each source to the level of mycotoxin contamination of dust, we developed techniques to harvest and separate mycelium-substrate matrices from spores of fungi. Conventional quantitative chromatographic analyses of separated materials indicated that aflatoxin from Aspergillus parasiticus, norsolorinic acid from a mutant of A. parasiticus, and secalonic acid D from Penicillium oxalicum were concentrated in the mycelium-substrate matrices and not in the spores. In contrast, spores of Aspergillus niger and Aspergillus fumigatus contained significant concentrations of aurasperone C and fumigaclavine C, respectively; only negligible amounts of the toxins were detected in the mycelium-substrate matrices of these two fungi. PMID:3709472

  5. Fate of pharmaceuticals in full-scale source separated sanitation system

    Butkovskyi, A.; Hernandez Leal, L.; Rijnaarts, H.H.M.; Zeeman, G.

    2015-01-01

    Removal of 14 pharmaceuticals and 3 of their transformation products was studied in a full-scale source separated sanitation system with separate collection and treatment of black water and grey water. Black water is treated in an up-flow anaerobic sludge blanket (UASB) reactor followed by

  6. Rhythmic entrainment source separation: Optimizing analyses of neural responses to rhythmic sensory stimulation

    Cohen, M.S.; Gulbinaite, R.

    2017-01-01

    Steady-state evoked potentials (SSEPs) are rhythmic brain responses to rhythmic sensory stimulation, and are often used to study perceptual and attentional processes. We present a data analysis method for maximizing the signal-to-noise ratio of the narrow-band steady-state response in the frequency and time-frequency domains. The method, termed rhythmic entrainment source separation (RESS), is based on denoising source separation approaches that take advantage of the simultaneous but differen...

  7. Advances in the hydrometallurgical separation techniques of high purity rare earth elements

    Vijayalakshmi, R.; Kain, V.

    2017-01-01

    Rare Earths are a series of 15 chemically similar elements that occur together in monazite mineral found in the beach sands of Kerala, Tamil Nadu and Orissa. The rare earth elements (REE) are becoming increasingly strategically important considering their essential role in permanent magnets such as, SmCo_5, Sm_2Co_1_7 and Nd_2Fe_1_4B, phosphors for LED screens and lamps, rechargeable nickel metal hydride batteries and catalysts and other green applications. The increasing popularity of hybrid and electric cars, wind turbines and compact fluorescent lamps is causing an increase in the demand and price of REE. The European Commission considers the REE as the most critical raw materials group, with the highest supply risk. According to the medium-term criticality matrix of the U.S. Department of Energy (DOE), the five most critical REE are neodymium (Nd), europium (Eu), terbium (Tb), dysprosium (Dy) and yttrium (Y). China is presently producing more than 90% of all rare earths, although they possess less than 405 of the proven reserves. Due to large and increasing domestic demands, China tightened its REE export quota from 2012 onwards. These export quotas caused serious problems for REE users outside of China. Fortunately India is blessed with large resources of rare earths in the form of monazite found in the beach sands of Kerala, Tamil Nadu and Orissa. Indian Rare Earths Limited at Aluva near Kochi produces mainly mixed rare earths chloride and till recent past exporting to USA, UK, France, Japan, etc. They have revived their rare earth separation plant to meet the in-house demands of the strategic, defense and nuclear industry. This paper discusses the recent advances made in hydrometallurgical separation techniques based on solvent extraction technique, ion-exchange resins, hollow fibre membrane extractor, solvent encapsulated polymeric beads, etc for the production of high purity rare earth elements from both primary (Monazite, xenotime) and secondary sources

  8. Factors influencing source separation intention and willingness to pay for improving waste management in Bangkok, Thailand

    Sujitra Vassanadumrongdee

    2018-03-01

    Full Text Available Source separation for recycling has been recognized as a way to achieve sustainable municipal solid waste (MSW management. However, most developing countries including Thailand have been facing with lack of recycling facilities and low level of source separation practice. By employing questionnaire surveys, this study investigated Bangkok residents' source separation intention and willingness to pay (WTP for improving MSW service and recycling facilities (n = 1076. This research extended the theory of planned behavior to explore the effects of both internal and external factors. The survey highlighted perceived inconvenience and mistrust on MSW collection being major barriers to carrying out source separation in Bangkok. Promoting source separation at workplace may possibly create spill-over effect to people's intention to recycle their waste at home. Both subjective norms and knowledge on MSW situation were found to be a positive correlation with Bangkok residents' source separation intention and WTP (p < 0.001. Besides, the average WTP values are higher than the existing rate of waste collection service, which shows that Bangkok residents have preference for recycling programs. However, the WTP figures are still much lower than the average MSW management cost. These findings suggest that Bangkok Metropolitan Administration targets improving people knowledge on waste problems that could have adverse impact on the economy and well-being of Bangkok residents and improve its MSW collection service as these factors have positive influence on residents' WTP.

  9. Application of separable parameter space techniques to multi-tracer PET compartment modeling

    Zhang, Jeff L; Michael Morey, A; Kadrmas, Dan J

    2016-01-01

    Multi-tracer positron emission tomography (PET) can image two or more tracers in a single scan, characterizing multiple aspects of biological functions to provide new insights into many diseases. The technique uses dynamic imaging, resulting in time-activity curves that contain contributions from each tracer present. The process of separating and recovering separate images and/or imaging measures for each tracer requires the application of kinetic constraints, which are most commonly applied by fitting parallel compartment models for all tracers. Such multi-tracer compartment modeling presents challenging nonlinear fits in multiple dimensions. This work extends separable parameter space kinetic modeling techniques, previously developed for fitting single-tracer compartment models, to fitting multi-tracer compartment models. The multi-tracer compartment model solution equations were reformulated to maximally separate the linear and nonlinear aspects of the fitting problem, and separable least-squares techniques were applied to effectively reduce the dimensionality of the nonlinear fit. The benefits of the approach are then explored through a number of illustrative examples, including characterization of separable parameter space multi-tracer objective functions and demonstration of exhaustive search fits which guarantee the true global minimum to within arbitrary search precision. Iterative gradient-descent algorithms using Levenberg–Marquardt were also tested, demonstrating improved fitting speed and robustness as compared to corresponding fits using conventional model formulations. The proposed technique overcomes many of the challenges in fitting simultaneous multi-tracer PET compartment models. (paper)

  10. Separation of Correlated Astrophysical Sources Using Multiple-Lag Data Covariance Matrices

    Baccigalupi C

    2005-01-01

    Full Text Available This paper proposes a new strategy to separate astrophysical sources that are mutually correlated. This strategy is based on second-order statistics and exploits prior information about the possible structure of the mixing matrix. Unlike ICA blind separation approaches, where the sources are assumed mutually independent and no prior knowledge is assumed about the mixing matrix, our strategy allows the independence assumption to be relaxed and performs the separation of even significantly correlated sources. Besides the mixing matrix, our strategy is also capable to evaluate the source covariance functions at several lags. Moreover, once the mixing parameters have been identified, a simple deconvolution can be used to estimate the probability density functions of the source processes. To benchmark our algorithm, we used a database that simulates the one expected from the instruments that will operate onboard ESA's Planck Surveyor Satellite to measure the CMB anisotropies all over the celestial sphere.

  11. Life Cycle Assessment of pretreatment technologies for anaerobic digestion of source-separated organic household waste

    Naroznova, Irina; Møller, Jacob; Scheutz, Charlotte

    2013-01-01

    The environmental performance of two pretreatment technologies for source-separated organic waste was compared using life cycle assessment (LCA). An innovative pulping process where source-separated organic waste is pulped with cold water forming a volatile solid rich biopulp was compared to a more...... including a number of non-toxic and toxic impact categories were assessed. No big difference in the overall performance of the two technologies was observed. The difference for the separate life cycle steps was, however, more pronounced. More efficient material transfer in the scenario with waste pulping...

  12. Materials recovery system for source-separated noncombustible rubbish and bulky waste in Nishinomiya

    Adachi, Yoshihiro

    1987-01-01

    Since 1980, the city of Nishinomiya has been recovering materials from source-separated non-combustible and bulky waste to reduce the amount of final disposal. Materials amounting to 33-39% of the throughput are recovered in the Shredding and Separation Facility, which consists of a manual separation system, a mechanical separation system, a shredder, a pair of shears and incinerators. The facility system is shown in order of processing of the waste. The secondary pollution control, safety equipment, instrumentation, etc., are also described. The recovery percentage and use of revenues are explained in detail.

  13. Prospects of Source-Separation-Based Sanitation Concepts: A Model-Based Study

    Cees Buisman

    2013-07-01

    Full Text Available Separation of different domestic wastewater streams and targeted on-site treatment for resource recovery has been recognized as one of the most promising sanitation concepts to re-establish the balance in carbon, nutrient and water cycles. In this study a model was developed based on literature data to compare energy and water balance, nutrient recovery, chemical use, effluent quality and land area requirement in four different sanitation concepts: (1 centralized; (2 centralized with source-separation of urine; (3 source-separation of black water, kitchen refuse and grey water; and (4 source-separation of urine, feces, kitchen refuse and grey water. The highest primary energy consumption of 914 MJ/capita(cap/year was attained within the centralized sanitation concept, and the lowest primary energy consumption of 437 MJ/cap/year was attained within source-separation of urine, feces, kitchen refuse and grey water. Grey water bio-flocculation and subsequent grey water sludge co-digestion decreased the primary energy consumption, but was not energetically favorable to couple with grey water effluent reuse. Source-separation of urine improved the energy balance, nutrient recovery and effluent quality, but required larger land area and higher chemical use in the centralized concept.

  14. Determination of sulfate in thorium salts using gravimetric technique with previous thorium separation

    Silva, C.M. da; Pires, M.A.F.

    1994-01-01

    Available as short communication only. A simple analytical method to analyze sulfates in thorium salt, is presented. The method is based on the thorium separation as hydroxide. The gravimetric technique is used to analyze the sulfate in the filtered as barium sulfate. Using this method, the sulfate separation from thorium has been reach 99,9% yield, and 0,1% precision. This method is applied to thorium salts specifically thorium sulfate, carbonate and nitrate. (author). 5 refs, 2 tabs

  15. Charge separation technique for metal-oxide-silicon capacitors in the presence of hydrogen deactivated dopants

    Witczak, Steven C.; Winokur, Peter S.; Lacoe, Ronald C.; Mayer, Donald C.

    2000-01-01

    An improved charge separation technique for metal-oxide-silicon (MOS) capacitors is presented which accounts for the deactivation of substrate dopants by hydrogen at elevated irradiation temperatures or small irradiation biases. Using high-frequency capacitance-voltage (C-V) measurements, radiation-induced inversion voltage shifts are separated into components due to oxide trapped charge, interface traps and deactivated dopants, where the latter is computed from a reduction in Si capacitance. In the limit of no radiation-induced dopant deactivation, this approach reduces to the standard midgap charge separation technique used widely for the analysis of room-temperature irradiations. The technique is demonstrated on a p-type MOS capacitor irradiated with 60 Co γ-rays at 100 C and zero bias, where the dopant deactivation is significant

  16. Using spatiotemporal source separation to identify prominent features in multichannel data without sinusoidal filters.

    Cohen, Michael X

    2017-09-27

    The number of simultaneously recorded electrodes in neuroscience is steadily increasing, providing new opportunities for understanding brain function, but also new challenges for appropriately dealing with the increase in dimensionality. Multivariate source separation analysis methods have been particularly effective at improving signal-to-noise ratio while reducing the dimensionality of the data and are widely used for cleaning, classifying and source-localizing multichannel neural time series data. Most source separation methods produce a spatial component (that is, a weighted combination of channels to produce one time series); here, this is extended to apply source separation to a time series, with the idea of obtaining a weighted combination of successive time points, such that the weights are optimized to satisfy some criteria. This is achieved via a two-stage source separation procedure, in which an optimal spatial filter is first constructed and then its optimal temporal basis function is computed. This second stage is achieved with a time-delay-embedding matrix, in which additional rows of a matrix are created from time-delayed versions of existing rows. The optimal spatial and temporal weights can be obtained by solving a generalized eigendecomposition of covariance matrices. The method is demonstrated in simulated data and in an empirical electroencephalogram study on theta-band activity during response conflict. Spatiotemporal source separation has several advantages, including defining empirical filters without the need to apply sinusoidal narrowband filters. © 2017 Federation of European Neuroscience Societies and John Wiley & Sons Ltd.

  17. Audio Source Separation in Reverberant Environments Using β-Divergence-Based Nonnegative Factorization

    Fakhry, Mahmoud; Svaizer, Piergiorgio; Omologo, Maurizio

    2017-01-01

    -maximization algorithm and used to separate the signals by means of multichannel Wiener filtering. We propose to estimate these parameters by applying nonnegative factorization based on prior information on source variances. In the nonnegative factorization, spectral basis matrices can be defined as the prior...... information. The matrices can be either extracted or indirectly made available through a redundant library that is trained in advance. In a separate step, applying nonnegative tensor factorization, two algorithms are proposed in order to either extract or detect the basis matrices that best represent......In Gaussian model-based multichannel audio source separation, the likelihood of observed mixtures of source signals is parametrized by source spectral variances and by associated spatial covariance matrices. These parameters are estimated by maximizing the likelihood through an expectation...

  18. Multiple Speech Source Separation Using Inter-Channel Correlation and Relaxed Sparsity

    Maoshen Jia

    2018-01-01

    Full Text Available In this work, a multiple speech source separation method using inter-channel correlation and relaxed sparsity is proposed. A B-format microphone with four spatially located channels is adopted due to the size of the microphone array to preserve the spatial parameter integrity of the original signal. Specifically, we firstly measure the proportion of overlapped components among multiple sources and find that there exist many overlapped time-frequency (TF components with increasing source number. Then, considering the relaxed sparsity of speech sources, we propose a dynamic threshold-based separation approach of sparse components where the threshold is determined by the inter-channel correlation among the recording signals. After conducting a statistical analysis of the number of active sources at each TF instant, a form of relaxed sparsity called the half-K assumption is proposed so that the active source number in a certain TF bin does not exceed half the total number of simultaneously occurring sources. By applying the half-K assumption, the non-sparse components are recovered by regarding the extracted sparse components as a guide, combined with vector decomposition and matrix factorization. Eventually, the final TF coefficients of each source are recovered by the synthesis of sparse and non-sparse components. The proposed method has been evaluated using up to six simultaneous speech sources under both anechoic and reverberant conditions. Both objective and subjective evaluations validated that the perceptual quality of the separated speech by the proposed approach outperforms existing blind source separation (BSS approaches. Besides, it is robust to different speeches whilst confirming all the separated speeches with similar perceptual quality.

  19. Separation of zeros for source signature identification under reverberant path conditions.

    Hasegawa, Tomomi; Tohyama, Mikio

    2011-10-01

    This paper presents an approach to distinguishing the zeros representing a sound source from those representing the transfer function on the basis of Lyon's residue-sign model. In machinery noise diagnostics, the source signature must be separated from observation records under reverberant path conditions. In numerical examples and an experimental piano-string vibration analysis, the modal responses could be synthesized by using clustered line-spectrum modeling. The modeling error represented the source signature subject to the source characteristics being given by a finite impulse response. The modeling error can be interpreted as a remainder function necessary for the zeros representing the source signature. © 2011 Acoustical Society of America

  20. Developing methodologies for source attribution. Glass phase separation in Trinitite using NF{sub 3}

    Koeman, Elizabeth C.; Simonetti, Antonio [Notre Dame Univ., IN (United States). Dept. of Civil and Environmental Engineering and Earth Sciences; McNamara, Bruce K.; Smith, Frances N. [Pacific Northwest National Laboratory, Richland, WA (United States). Nuclear Chemistry and Engineering; Burns, Peter C. [Notre Dame Univ., IN (United States). Dept. of Civil and Environmental Engineering and Earth Sciences; Notre Dame Univ., IN (United States). Dept. of Chemistry and Biochemistry

    2017-08-01

    separation of silica from minerals (i.e. naturally occurring crystalline materials) and glasses (i.e. amorphous materials), leaving behind non-volatile fluorinated species and refractory phases. The results from our investigation clearly indicate that the NF{sub 3} treatment of nuclear materials is a technique that provides effective separation of bomb components from complex matrices (e.g. post-detonation samples), which will aid with rapid and accurate source attribution.

  1. Life cycle assessment of a household solid waste source separation programme: a Swedish case study.

    Bernstad, Anna; la Cour Jansen, Jes; Aspegren, Henrik

    2011-10-01

    The environmental impact of an extended property close source-separation system for solid household waste (i.e., a systems for collection of recyclables from domestic properties) is investigated in a residential area in southern Sweden. Since 2001, households have been able to source-separate waste into six fractions of dry recyclables and food waste sorting. The current system was evaluated using the EASEWASTE life cycle assessment tool. Current status is compared with an ideal scenario in which households display perfect source-separation behaviour and a scenario without any material recycling. Results show that current recycling provides substantial environmental benefits compared to a non-recycling alternative. The environmental benefit varies greatly between recyclable fractions, and the recyclables currently most frequently source-separated by households are often not the most beneficial from an environmental perspective. With optimal source-separation of all recyclables, the current net contribution to global warming could be changed to a net-avoidance while current avoidance of nutrient enrichment, acidification and photochemical ozone formation could be doubled. Sensitivity analyses show that the type of energy substituted by incineration of non-recycled waste, as well as energy used in recycling processes and in the production of materials substituted by waste recycling, is of high relevance for the attained results.

  2. Municipal solid waste source-separated collection in China: A comparative analysis

    Tai Jun; Zhang Weiqian; Che Yue; Feng Di

    2011-01-01

    A pilot program focusing on municipal solid waste (MSW) source-separated collection was launched in eight major cities throughout China in 2000. Detailed investigations were carried out and a comprehensive system was constructed to evaluate the effects of the eight-year implementation in those cities. This paper provides an overview of different methods of collection, transportation, and treatment of MSW in the eight cities; as well as making a comparative analysis of MSW source-separated collection in China. Information about the quantity and composition of MSW shows that the characteristics of MSW are similar, which are low calorific value, high moisture content and high proportion of organisms. Differences which exist among the eight cities in municipal solid waste management (MSWM) are presented in this paper. Only Beijing and Shanghai demonstrated a relatively effective result in the implementation of MSW source-separated collection. While the six remaining cities result in poor performance. Considering the current status of MSWM, source-separated collection should be a key priority. Thus, a wider range of cities should participate in this program instead of merely the eight pilot cities. It is evident that an integrated MSWM system is urgently needed. Kitchen waste and recyclables are encouraged to be separated at the source. Stakeholders involved play an important role in MSWM, thus their responsibilities should be clearly identified. Improvement in legislation, coordination mechanisms and public education are problematic issues that need to be addressed.

  3. Review of procedures involving separation and preconcentration for the determination of cadmium using spectrometric techniques

    Ferreira, Sergio L.C.; Andrade, Jailson B. de; Korn, Maria das Gracas A.; Pereira, Madson de G.; Lemos, Valfredo A.; Santos, Walter N.L. dos; Rodrigues, Frederico de Medeiros; Souza, Anderson S.; Ferreira, Hadla S.; Silva, Erik G.P. da

    2007-01-01

    Spectrometric techniques for the analysis of trace cadmium have developed rapidly due to the increasing need for accurate measurements at extremely low levels of this element in diverse matrices. This review covers separation and preconcentration procedures, such as electrochemical deposition, precipitation, coprecipitation, solid phase extraction, liquid-liquid extraction (LLE) and cloud point extraction (CPE), and consider the features of the their application with several spectrometric techniques

  4. Radioactive source calibration technique for the CMS hadron calorimeter

    Hazen, E.; Lawlor, C.; Rohlf, J.W. E-mail: rohlf@bu.edu; Wu, S.X.; Baumbaugh, A.; Elias, J.E.; Freeman, J.; Green, D.; Lazic, D.; Los, S.; Ronzhin, A.; Sergueev, S.; Shaw, T.; Vidal, R.; Whitmore, J.; Zimmerman, T.; Adams, M.; Burchesky, K.; Qian, W.; Baden, A.; Bard, R.; Breden, H.; Grassi, T.; Skuja, A.; Fisher, W.; Mans, J.; Tully, C.; Barnes, V.; Laasanen, A.; Barbaro, P. de; Budd, H

    2003-10-01

    Relative calibration of the scintillator tiles used in the hadronic calorimeter for the Compact Muon Solenoid detector at the CERN Large Hadron Collider is established and maintained using a radioactive source technique. A movable source can be positioned remotely to illuminate each scintillator tile individually, and the resulting photo-detector current is measured to provide the relative calibration. The unique measurement technique described here makes use of the normal high-speed data acquisition system required for signal digitization at the 40 MHz collider frequency. The data paths for collider measurements and source measurements are then identical, and systematic uncertainties associated with having different signal paths are avoided. In this high-speed mode, the source signal is observed as a Poisson photo-electron distribution with a mean that is smaller than the width of the electronics noise (pedestal) distribution. We report demonstration of the technique using prototype electronics for the complete readout chain and show the typical response observed with a 144 channel test beam system. The electronics noise has a root-mean-square of 1.6 least counts, and a 1 mCi source produces a shift of the mean value of 0.1 least counts. Because of the speed of the data acquisition system, this shift can be measured to a statistical precision better than a fraction of a percent on a millisecond time scale. The result is reproducible to better than 2% over a time scale of 1 month.

  5. Long-term program for research and development of group separation and disintegration techniques

    1988-01-01

    In Japan, the basic guidelines state that high-level radioactive wastes released from reprocessing of spent fuel should be processed into stable solid material, followed by storage for cooling for 30-50 years and disposal in the ground at a depth of several hundreds of meters. The Long-Term Program for Research and Development of Group Separation and Disintegration Techniques is aimed at efficient disposal of high-level wastes, reutilization of useful substances contained, and improved safety. Important processes include separation of nuclides (group separation, individual nuclide separation) and conversion (disintegration) of long-lived nuclides into short-lived or non-radioactive one. These processes can reduce the volume of high-level wastes to be left for final disposal. Research and development projects have been under way to provide techniques to separate high-level waste substances into four groups (transuranic elements, strontium/cesium, technetium/platinum group elements, and others). These projects also cover recovery of useful metals and efficient utilization of separated substances. For disintegration, conceptual studies have been carried out for the application of fast neutron beams to conversion of long half-life transuranium elements into short half-life or non-radioactive elements. (N.K.)

  6. Magnetic resonance separation imaging using a divided inversion recovery technique (DIRT).

    Goldfarb, James W

    2010-04-01

    The divided inversion recovery technique is an MRI separation method based on tissue T(1) relaxation differences. When tissue T(1) relaxation times are longer than the time between inversion pulses in a segmented inversion recovery pulse sequence, longitudinal magnetization does not pass through the null point. Prior to additional inversion pulses, longitudinal magnetization may have an opposite polarity. Spatial displacement of tissues in inversion recovery balanced steady-state free-precession imaging has been shown to be due to this magnetization phase change resulting from incomplete magnetization recovery. In this paper, it is shown how this phase change can be used to provide image separation. A pulse sequence parameter, the time between inversion pulses (T180), can be adjusted to provide water-fat or fluid separation. Example water-fat and fluid separation images of the head, heart, and abdomen are presented. The water-fat separation performance was investigated by comparing image intensities in short-axis divided inversion recovery technique images of the heart. Fat, blood, and fluid signal was suppressed to the background noise level. Additionally, the separation performance was not affected by main magnetic field inhomogeneities.

  7. Capillary electrokinetic separation techniques for profiling of drugs and related products

    Hilhorst, M.J; Somsen, G.W; de Jong, G.J.

    Capillary electrokinetic separation techniques offer high efficiency and peak capacity, and can be very useful for the analysis of samples containing a large variety of (unknown) compounds. Such samples are frequently met in impurity profiling of drugs (detection of potential impurities in a

  8. Adsorption combined with superconducting high gradient magnetic separation technique used for removal of arsenic and antimony.

    Qi, Zenglu; Joshi, Tista Prasai; Liu, Ruiping; Li, Yiran; Liu, Huijuan; Qu, Jiuhui

    2018-02-05

    Manganese iron oxide (MnFe 2 O 4 ), an excellent arsenic(As)/antimony(Sb) removal adsorbent, is greatly restricted for the solid-liquid separation. Through the application of superconducting high gradient magnetic separation (HGMS) technique, we herein constructed a facility for the in situ solid-liquid separation of micro-sized MnFe 2 O 4 adsorbent in As/Sb removal process. To the relative low initial concentration 50.0μgL -1 , MnFe 2 O 4 material sorbent can still decrease As or Sb below US EPA's drinking water standard limit. The separation of MnFe 2 O 4 was mainly relied on the flow rate and the amount of steel wools in the HGMS system. At a flow rate 1Lmin -1 and 5% steel wools filling rate, the removal efficacies of As and Sb in natural water with the system were achieved to be 94.6% and 76.8%, respectively. At the meantime, nearly 100% micro-sized MnFe 2 O 4 solid in the continuous field was readily to be separated via HGMS system. In a combination with the experiment results and finite element simulation, the separation was seemed to be independent on the magnetic field intensity, and the maximum separation capacities in various conditions were well predicted using the Thomas model (R 2 =0.87-0.99). Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Review of Sealed Source Designs and Manufacturing Techniques Affecting Disused Source Management

    2012-10-01

    This publication presents an investigation on the influence of the design and technical features of sealed radioactive sources (SRSs) on predisposal and disposal activities when the sources become disused. The publication also addresses whether design modifications could contribute to safer and/or more efficient management of disused sources without compromising the benefits provided by the use of the sealed sources. This technical publication aims to collect information on the most typical design features and manufacturing techniques of sealed radioactive sources and examines how they affect the safe management of disused sealed radioactive sources (DSRS). The publication also aims to assist source designers and manufacturers by discussing design features that are important from the waste management point of view. It has been identified that most SRS manufacturers use similar geometries and materials for their designs and apply improved and reliable manufacturing techniques e.g. double- encapsulation. These designs and manufacturing techniques have been proven over time to reduce contamination levels in fabrication and handling, and improve source integrity and longevity. The current source designs and materials ensure as well as possible that SRSs will maintain their integrity in use and when they become disused. No significant improvement options to current designs have been identified. However, some design considerations were identified as important to facilitate source retrieval, to increase the possibility of re-use and to ensure minimal contamination risk and radioactive waste generation at recycling. It was also concluded that legible identifying markings on a source are critical for DSRS management. The publication emphasizes the need for a common understanding of the radioactive source's recommended working life (RWL) for manufacturers and regulators. The conditions of use (COU) are important for the determination of RWL. A formal system for specification

  10. Laser sources and techniques for spectroscopy and dynamics

    Kung, A.H. [Lawrence Berkeley Laboratory, CA (United States)

    1993-12-01

    This program focuses on the development of novel laser and spectroscopic techniques in the IR, UV, and VUV regions for studying combustion related molecular dynamics at the microscopic level. Laser spectroscopic techniques have proven to be extremely powerful in the investigation of molecular processes which require very high sensitivity and selectivity. The authors approach is to use quantum electronic and non-linear optical techniques to extend the spectral coverage and to enhance the optical power of ultrahigh resolution laser sources so as to obtain and analyze photoionization, fluorescence, and photoelectron spectra of jet-cooled free radicals and of reaction products resulting from unimolecular and bimolecular dissociations. New spectroscopic techniques are developed with these sources for the detection of optically thin and often short-lived species. Recent activities center on regenerative amplification of high resolution solid-state lasers, development of tunable high power mid-IR lasers and short-pulse UV/VUV tunable lasers, and development of a multipurpose high-order suppressor crossed molecular beam apparatus for use with synchrotron radiation sources. This program also provides scientific and technical support within the Chemical Sciences Division to the development of LBL`s Combustion Dynamics Initiative.

  11. Treatment of Source-Separated Blackwater: A Decentralized Strategy for Nutrient Recovery towards a Circular Economy

    Melesse Eshetu Moges; Daniel Todt; Arve Heistad

    2018-01-01

    Using a filter medium for organic matter removal and nutrient recovery from blackwater treatment is a novel concept and has not been investigated sufficiently to date. This paper demonstrates a combined blackwater treatment and nutrient-recovery strategy and establishes mechanisms for a more dependable source of plant nutrients aiming at a circular economy. Source-separated blackwater from a student dormitory was used as feedstock for a sludge blanket anaerobic-baffled reactor. The effluent f...

  12. Cultured Cortical Neurons Can Perform Blind Source Separation According to the Free-Energy Principle

    Isomura, Takuya; Kotani, Kiyoshi; Jimbo, Yasuhiko

    2015-01-01

    Blind source separation is the computation underlying the cocktail party effect––a partygoer can distinguish a particular talker’s voice from the ambient noise. Early studies indicated that the brain might use blind source separation as a signal processing strategy for sensory perception and numerous mathematical models have been proposed; however, it remains unclear how the neural networks extract particular sources from a complex mixture of inputs. We discovered that neurons in cultures of dissociated rat cortical cells could learn to represent particular sources while filtering out other signals. Specifically, the distinct classes of neurons in the culture learned to respond to the distinct sources after repeating training stimulation. Moreover, the neural network structures changed to reduce free energy, as predicted by the free-energy principle, a candidate unified theory of learning and memory, and by Jaynes’ principle of maximum entropy. This implicit learning can only be explained by some form of Hebbian plasticity. These results are the first in vitro (as opposed to in silico) demonstration of neural networks performing blind source separation, and the first formal demonstration of neuronal self-organization under the free energy principle. PMID:26690814

  13. Cultured Cortical Neurons Can Perform Blind Source Separation According to the Free-Energy Principle.

    Takuya Isomura

    2015-12-01

    Full Text Available Blind source separation is the computation underlying the cocktail party effect--a partygoer can distinguish a particular talker's voice from the ambient noise. Early studies indicated that the brain might use blind source separation as a signal processing strategy for sensory perception and numerous mathematical models have been proposed; however, it remains unclear how the neural networks extract particular sources from a complex mixture of inputs. We discovered that neurons in cultures of dissociated rat cortical cells could learn to represent particular sources while filtering out other signals. Specifically, the distinct classes of neurons in the culture learned to respond to the distinct sources after repeating training stimulation. Moreover, the neural network structures changed to reduce free energy, as predicted by the free-energy principle, a candidate unified theory of learning and memory, and by Jaynes' principle of maximum entropy. This implicit learning can only be explained by some form of Hebbian plasticity. These results are the first in vitro (as opposed to in silico demonstration of neural networks performing blind source separation, and the first formal demonstration of neuronal self-organization under the free energy principle.

  14. Gas separation techniques with liquid Ar for production of 11C ions

    Hojo, Satoru; Honma, Toshihiro; Kanazawa, Mitsutaka; Muramatsu, Masayuki; Sakamoto, Yukio; Sugiura, Akinori; Suzuki, Naokata; Noda, Koji

    2009-01-01

    Heavy-ion cancer therapy with 12 C-beam has been carried out at HIMAC (Heavy Ion Medical Accelerator in Chiba) in NIRS (National Institute of Radiological Sciences) since 1994. One of the feasibility study in HIMAC is to use a positron emitter beam such as 11 C-beam for the cancer therapy. A nuclear reaction, 14 N (p,α) 11 C will be applied in the present study; it can be expected to obtain a considerably large number of 11 C-particles by utilizing the commonly used short-lives RI production techniques for PET (Positron Emission Tomography). The amount of 11 C gas is limited in this technique. The 11 CO 2 gas was produced from N 2 gas that is irradiated high-energy proton beam. Therefore, CO 2 gas separation from N 2 gas is very important. The gas-separation techniques with cryogenic system utilizing a liquid Ar were tested by dummy gas (N 2 + 12 CO 2 ). Details of the gas-separation techniques and measurement of CO 2 partial pressure are discussed. (author)

  15. Development of novel separation techniques for biological samples in capillary electrophoresis

    Chang, Huan -Tsung [Iowa State Univ., Ames, IA (United States)

    1994-07-27

    This dissertation includes three different topics: general introduction of capillary electrophoresis (CE); gradient in CE and CE in biological separations; and capillary gel electrophoresis (CGE) for DNA separation. Factors such as temperature, viscosity, pH, and the surface of capillary walls affecting the separation performance are demonstrated. A pH gradient between 3.0 and 5.2 is useful to improve the resolution among eight different organic acids. A flow gradient due to the change in the concentration of surfactant, which is able to coat to the capillary wall to change the flow rate and its direction, is also shown as a good way to improve the resolution for organic compounds. A temperature gradient caused by joule heat is shown by voltage programming to enhance the resolution and shorten the separation time for several phenolic compounds. The author also shows that self-regulating dynamic control of electroosmotic flow in CE by simply running separation in different concentrations of surfactant has less matrix effect on the separation performance. One of the most important demonstrations in this dissertation is that the author proposes on-column reaction which gives several advantages including the use of a small amount of sample, low risk of contamination, and time saving and kinetic features. The author uses this idea with laser induced fluorescence (LIF) as a detection mode to detect an on-column digestion of sub-ng of protein. This technique also is applied to single cell analysis in the group.

  16. Study on magnetic separation system using high Tc superconducting bulk magnets for water purification technique

    Oka, T; Kanayama, H; Tanaka, K; Fukui, S; Ogawa, J; Sato, T; Ooizumi, M; Yamaguchi, M; Yokoyama, K; Noto, K

    2009-01-01

    The application of superconducting bulk magnets to the magnetic separation techniques has been investigated for the Mn-bearing waste water drained from the university laboratories. The research has been conducted in comparison with the electromagnets, and the cryo-cooled superconducting solenoid magnet. The separation ratios of ferrite precipitates including Mn element in the waste slurry were estimated by means of the high gradient magnetic separation method with ferromagnetic iron filters in the water channel and open gradient magnetic separation without them. As the magnetic force acting on the particles is given by the product of a magnetization of particles and a gradient of magnetic field, and a superconducting bulk magnet shows a sharp gradient of the magnetic field on the surface, the performances of the bulk magnet system were almost equivalent to those of the superconducting solenoid magnet with wide bore with respect to the magnetic separation ratios. The separation ratios for Mn have reached over 80 % for HGMS and 10 % for OGMS under the flow rates less than 3 liter/min.

  17. Separation of arsenic species by capillary electrophoresis with sample-stacking techniques

    Chen, Zu Liang; Naidu, Ravendra [Adelaide Laboratory, CSIRO Land and Water, PMB2, 5064, Glen Osmond, SA (Australia); Lin, Jin-Ming [Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, P.O. Box 2871, 100085, Beijing (China)

    2003-03-01

    A simple capillary zone electrophoresis procedure was developed for the separation of arsenic species (AsO{sub 2}{sup 2-}, AsO{sub 4}{sup 2-}, and dimethylarsinic acid, DMA). Both counter-electroosmotic and co-electroosmotic (EOF) modes were investigated for the separation of arsenic species with direct UV detection at 185 nm using 20 mmol L{sup -1} sodium phosphate as the electrolyte. The separation selectivity mainly depends on the separation modes and electrolyte pH. Inorganic anions (Cl{sup -}, NO{sub 2}{sup -}, NO{sub 3}{sup -} and SO{sub 4}{sup 2-}) presented in real samples did not interfere with arsenic speciation in either separation mode. To improve the detection limits, sample-stacking techniques, including large-volume sample stacking (LVSS) and field-amplified sample injection (FASI), were investigated for the preconcentration of As species in co-CZE mode. Less than 1 {mu}mol L{sup -1} of detection limits for As species were achieved using FASI. The proposed method was demonstrated for the separation and detection of As species in water. (orig.)

  18. Magnetic separation technique for environmental water purification by strong magnetic field generator loading HTS bulk magnets

    Oka, T.; Tanaka, K.; Kimura, T.; Mimura, D.; Fukui, S.; Ogawa, J.; Sato, T.; Ooizumi, M.; Yokoyama, K.; Yamaguchi, M.

    2010-01-01

    The magnetic separation technique in combination with high temperature superconducting bulk magnets has been investigated to purify the ground water which has been used in the coolant system for the incinerator furnace to cool the burning gas. The experiment has been operated by means of the newly-built alternating channel type magnetic separating device. The separation ratios of ferromagnetic flocks including fine magnetite powder have been estimated by means of the high gradient magnetic separation method with small iron balls filled in the water channels. As the magnetic force acting on the magnetic particle is given by the product of a magnetization of the material and a gradient of magnetic field, and as the ferromagnetic stainless steel balls yield the steep gradient of magnetic field around them in a strong magnetic field, the system has exhibited a quite excellent performance with respect to the separation ratios. The separation ratios of the flocks which contain the magnetite powder with the values more than 50 ppm have remained over 80% for under the flow rates less than 5 L/min.

  19. Residents’ Preferences for Household Kitchen Waste Source Separation Services in Beijing: A Choice Experiment Approach

    Yalin Yuan

    2014-12-01

    Full Text Available A source separation program for household kitchen waste has been in place in Beijing since 2010. However, the participation rate of residents is far from satisfactory. This study was carried out to identify residents’ preferences based on an improved management strategy for household kitchen waste source separation. We determine the preferences of residents in an ad hoc sample, according to their age level, for source separation services and their marginal willingness to accept compensation for the service attributes. We used a multinomial logit model to analyze the data, collected from 394 residents in Haidian and Dongcheng districts of Beijing City through a choice experiment. The results show there are differences of preferences on the services attributes between young, middle, and old age residents. Low compensation is not a major factor to promote young and middle age residents accept the proposed separation services. However, on average, most of them prefer services with frequent, evening, plastic bag attributes and without instructor. This study indicates that there is a potential for local government to improve the current separation services accordingly.

  20. Survival of enteric bacteria in source-separated human urine used ...

    MAKAYA

    Urine in Pumpkin (Cucurbita maxima) Cultivation. Agric. Food Sci. 18:57-68. Pronk W, Koné D (2010). Options for urine treatment in developing countries. Desalination 251:360-368. Schönning C, Leeming R, Stenström TA (2002). Faecal contamination of source-separated human urine based on the content of faecal sterols ...

  1. Source Separation and Treament of Anthropogenic Urine (WERF Report INFR4SG09b)

    Abstract: Anthropogenic urine, although only 1% of domestic wastewater flow, is responsible for 50-80% of the nutrients and a substantial portion of the pharmaceuticals and hormones present in the influent to wastewater treatment plants. Source separation and treatment of urine...

  2. Technologies for the treatment of source-separated urine in the ...

    Technologies for the treatment of source-separated urine in the eThekwini ... This practice can lead to environmental pollution, since urine contains high amounts of ... produces only distilled water and a small amount of sludge as by-products.

  3. A New Technique to Identify Arbitrarily Shaped Noise Sources

    Roberto A. Tenenbaum

    2006-01-01

    Full Text Available Acoustic intensity is one of the available tools for evaluating sound radiation from vibrating bodies. Active intensity may, in some situations, not give a faithful insight about how much energy is in fact carried into the far field. It was then proposed a new parameter, the supersonic acoustic intensity, which takes into account only the intensity generated by components having a smaller wavenumber than the acoustic one. However, the method is only efective for simple sources, such as plane plates, cylinders and spheres. This work presents a new technique, based on the Boundary Elements Method and the Singular Value Decomposition, to compute the supersonic acoustic intensity for arbitrarily shaped sources. The technique is based in the Kirchoff-Helmholtz equation in a discretized approach, leading to a radiation operator that relates the normal velocity on the source's surface mesh with the pressure at grid points located in the field. Then, the singular value decomposition technique is set to the radiation operator and a cutoff criterion is applied to remove non propagating components. Some numerical examples are presented.

  4. Agronomic evaluation of guano sources by means of isotope techniques

    Zapata, F.; Arrillaga, J.L.

    2002-01-01

    Many soils of the tropics and subtropics under continuous cultivation are very infertile, thus poor yields are obtained and little crop residues remain to protect the soils from degrading erosion. External nutrient inputs in the form of chemical fertilizers, organic materials and other nutrients sources are essential for developing sustainable agricultural production systems. As chemical fertilizers are costly for developing countries with insufficient foreign currency for their purchase and their supplies are limited and irregular for small landholders, alternative nutrient sources must be sought and evaluated for use in dominant agricultural production systems. Locally available organic materials of different origin are potential sources of nutrients. One such source with high agronomic potential is guano. The present study was carried out to evaluate the agronomic effectiveness of two guano materials of different origin (Zaire and Peru) as sources of nitrogen and phosphorus as compared to chemical fertilizers (ammonium sulfate and triple superphosphate) using isotopic ( 15 N and 32 P) techniques. Using the classical method of comparing dry matter weight and P uptake, no significant differences among the tested guano sources were found. The use of the isotopic techniques allowed a quantitative assessment of the N and P supply to crops. Both guano materials were found to be good sources of N but in contrast were poor sources of phosphorus. In addition, from the agronomic evaluation, it was found that the guano of Zaire and the ammonium sulfate were N sources of equivalent efficiency and the guano of Peru even slightly better than the ammonium sulfate. As expected, P in the single superphosphate was as available to the P in the triple superphosphate. However, the substitution ratios for the guano sources were relatively high. Thus, 1 kg P as single superphosphate was equivalent to 9.5 kg P as guano from Zaire or 12.5 kg P as guano from Peru. Further field trials in

  5. Auto white balance method using a pigmentation separation technique for human skin color

    Tanaka, Satomi; Kakinuma, Akihiro; Kamijo, Naohiro; Takahashi, Hiroshi; Tsumura, Norimichi

    2017-02-01

    The human visual system maintains the perception of colors of an object across various light sources. Similarly, current digital cameras feature an auto white balance function, which estimates the illuminant color and corrects the color of a photograph as if the photograph was taken under a certain light source. The main subject in a photograph is often a person's face, which could be used to estimate the illuminant color. However, such estimation is adversely affected by differences in facial colors among individuals. The present paper proposes an auto white balance algorithm based on a pigmentation separation method that separates the human skin color image into the components of melanin, hemoglobin and shading. Pigment densities have a uniform property within the same race that can be calculated from the components of melanin and hemoglobin in the face. We, thus, propose a method that uses the subject's facial color in an image and is unaffected by individual differences in facial color among Japanese people.

  6. Separation and sampling technique of light element isotopes by chemical exchange process

    Kato, Shunsaku; Oi, Kenta; Takagi, Norio; Hirotsu, Takafumi; Kano, Hirofumi; Sonoda, Akinari; Makita, Yoji

    2000-01-01

    Lithium and boron isotope separation technique were studied. Granulation of lithium isotope separation agent was carried out by cure covering in solution. Separation of lithium isotope was stepped up by ammonium carbonate used as elusion agent. Styrene and ester resin derived three kinds of agents such as 2-amino-1, 3-propanediol (1, 3-PD), 2-amino-2-methyl-1, 3-propanediol (Me-1,3-PD) and tris(2-hydroxyethyl)amine (Tris) were used as absorbent.The ester resin with Tris showed larger amount of adsorption (1.4 mmol/g) than other resins. However, all resins with agent indicated more large adsorption volume of boron than the objective value (0.5 mmol/g). Large isotope shift was shown by the unsymmetrical vibration mode of lithium ion on the basis of quantum chemical calculation of isotope effect on dehydration of hydrated lithium ion. (S.Y.)

  7. Validation of a simple isotopic technique for the measurement of global and separated renal function

    Chachati, A.; Meyers, A.; Rigo, P.; Godon, J.P.

    1986-01-01

    Schlegel and Gates described an isotopic method for the measurement of global and separated glomerular filtration rate (GFR) and effective renal plasma flow (ERPF) based on the determination by scintillation camera of the fraction of the injected dose (99mTc-DTPA-[ 131 I]hippuran) present in the kidneys 1-3 min after its administration. This method requires counting of the injected dose and attenuation correction, but no blood or urine sampling. We validated this technique by the simultaneous infusion of inulin and para-amino hippuric acid (PAH) in patients with various levels of renal function (anuric to normal). To better define individual renal function we studied 9 kidneys in patients either nephrectomized or with a nephrostomy enabling separated function measurement. A good correlation between inulin, PAH clearance, and isotopic GFR-ERPF measurement for both global and separate renal function was observed

  8. New test techniques to evaluate near field effects for supersonic store carriage and separation

    Sawyer, Wallace C.; Stallings, Robert L., Jr.; Wilcox, Floyd J., Jr.; Blair, A. B., Jr.; Monta, William J.; Plentovich, Elizabeth B.

    1989-01-01

    Store separation and store carriage drag studies were conducted. A primary purpose is to develop new experimental methods to evaluate near field effects of store separation and levels of store carriage drag associated with a variety of carriage techniques for different store shapes and arrangements. Flow field measurements consisting of surface pressure distributions and vapor screen photographs are used to analyze the variations of the store separation characteristics with cavity geometry. Store carriage drag measurements representative of tangent, semi-submerged, and internal carriage installations are presented and discussed. Results are included from both fully metric models and models with only metric segments (metric pallets) and the relative merits of the two are discussed. Carriage drag measurements for store installations on an aircraft parent body are compared both with prediction methods and with installations on a generic parent body.

  9. Enhanced protein electrophoresis technique for separating human skeletal muscle myosin heavy chain isoforms

    Bamman, M. M.; Clarke, M. S.; Talmadge, R. J.; Feeback, D. L.

    1999-01-01

    Talmadge and Roy (J. Appl. Physiol. 1993, 75, 2337-2340) previously established a sodium dodecyl sulfate - polyacrylamide gel electrophoresis (SDS-PAGE) protocol for separating all four rat skeletal muscle myosin heavy chain (MHC) isoforms (MHC I, IIa, IIx, IIb); however, when applied to human muscle, the type II MHC isoforms (Ila, IIx) are not clearly distinguished. In this brief paper we describe a modification of the SDS-PAGE protocol which yields distinct and consistent separation of all three adult human MHC isoforms (MHC I, IIa, IIx) in a minigel system. MHC specificity of each band was confirmed by Western blot using three monoclonal IgG antibodies (mAbs) immunoreactive against MHCI (mAb MHCs, Novacastra Laboratories), MHCI+IIa (mAb BF-35), and MHCIIa+IIx (mAb SC-71). Results provide a valuable SDS-PAGE minigel technique for separating MHC isoforms in human muscle without the difficult task of casting gradient gels.

  10. Noise-Source Separation Using Internal and Far-Field Sensors for a Full-Scale Turbofan Engine

    Hultgren, Lennart S.; Miles, Jeffrey H.

    2009-01-01

    Noise-source separation techniques for the extraction of the sub-dominant combustion noise from the total noise signatures obtained in static-engine tests are described. Three methods are applied to data from a static, full-scale engine test. Both 1/3-octave and narrow-band results are discussed. The results are used to assess the combustion-noise prediction capability of the Aircraft Noise Prediction Program (ANOPP). A new additional phase-angle-based discriminator for the three-signal method is also introduced.

  11. A review of microfabrication techniques and dielectrophoretic microdevices for particle manipulation and separation

    Li, M; Li, W H; Zhang, J; Alici, G; Wen, W

    2014-01-01

    The development of lab-on-a-chip (LOC) devices over the past decade has attracted growing interest. LOC devices aim to achieve the miniaturization, integration, automation and parallelization of biological and chemical assays. One of the applications, the ability to effectively and accurately manipulate and separate micro- and nano-scale particles in an aqueous solution, is particularly appealing in biological, chemical and medical fields. Among the technologies that have been developed and implemented in microfluidic microsystems for particle manipulation and separation (such as mechanical, inertial, hydrodynamic, acoustic, optical, magnetic and electrical methodologies), dielectrophoresis (DEP) may prove to be the most popular because of its label-free nature, ability to manipulate neutral bioparticles, analyse with high selectivity and sensitivity, compatibility with LOC devices, and easy and direct interface with electronics. The required spatial electric non-uniformities for the DEP effect can be generated by patterning microelectrode arrays within microchannels, or placing insulating obstacles within a microchannel and curving the microchannels. A wide variety of electrode- and insulator-based DEP microdevices have been developed, fabricated, and successfully employed to manipulate and separate bioparticles (i.e. DNA, proteins, bacteria, viruses, mammalian and yeast cells). This review provides an overview of the state-of-the-art of microfabrication techniques and of the structures of dielectrophoretic microdevices aimed towards different applications. The techniques used for particle manipulation and separation based on microfluidics are provided in this paper. In addition, we also present the theoretical background of DEP. (topical review)

  12. Basic studies of a gas-jet-coupled ion source for on-line isotope separation

    Anderl, R.A.; Novick, V.J.; Greenwood, R.C.

    1980-01-01

    A hollow-cathode ion source was used in a gas-jet-coupled configuration to produce ion beams of fission products transported to it from a 252 Cf fission source. Solid aerosols of NaCl and Ag were used effectively as activity carriers in the gas-jet system. Flat-plate skimmers provided an effective coupling of the ion source to the gas jet. Ge(Li) spectrometric measurements of the activity deposited on an ion-beam collector relative to that deposited on a pre-skimmer collector were used to obtain separation efficiencies ranging from 0.1% to > 1% for Sr, Y, Tc, Te, Cs, Ba, Ce, Pr, Nd and Sm. The use of CCl 4 as a support gas resulted in a significant enhancement of the alkaline-earth and rare-earth separation efficiencies

  13. Fiber Strain Measurement for Wide Region Quasidistributed Sensing by Optical Correlation Sensor with Region Separation Techniques

    Xunjian Xu

    2010-01-01

    Full Text Available The useful application of optical pulse correlation sensor for wide region quasidistributed fiber strain measurement is investigated. Using region separation techniques of wavelength multiplexing with FBGs and time multiplexing with intensity partial reflectors, the sensor measures the correlations between reference pulses and monitoring pulses from several cascadable selected sensing regions. This novel sensing system can select the regions and obtain the distributed strain information in any desired sensing region.

  14. Selective separation of Cu, Zn, and As from solution by flotation techniques

    Stalidis, G.A.; Matis, K.A.; Lazaridis, N.K.

    1989-01-01

    The selective precipitation and flotation of copper, zinc, and arsenic ions from dilute aqueous solutions were investigated. Phase separation was accomplished effectively by the dissolved-air technique for the production of fine gas bubbles, and a short-chain xanthate was applied as the collector for copper ions, dialkyl-dithiocarbamate for zinc, and ferric sulfate for the pentavalent arsenic. The procedures followed were ion flotation for copper and zinc, and adsorbing colloid flotation for arsenic (without a surfactant)

  15. Stratified source-sampling techniques for Monte Carlo eigenvalue analysis

    Mohamed, A.

    1998-01-01

    In 1995, at a conference on criticality safety, a special session was devoted to the Monte Carlo ''Eigenvalue of the World'' problem. Argonne presented a paper, at that session, in which the anomalies originally observed in that problem were reproduced in a much simplified model-problem configuration, and removed by a version of stratified source-sampling. In this paper, stratified source-sampling techniques are generalized and applied to three different Eigenvalue of the World configurations which take into account real-world statistical noise sources not included in the model problem, but which differ in the amount of neutronic coupling among the constituents of each configuration. It is concluded that, in Monte Carlo eigenvalue analysis of loosely-coupled arrays, the use of stratified source-sampling reduces the probability of encountering an anomalous result over that if conventional source-sampling methods are used. However, this gain in reliability is substantially less than that observed in the model-problem results

  16. [Clinical research of arthroscopic separate double-layer suture bridge technique for delaminated rotator cuff tear].

    Ren, Jiangtao; Xu, Cong; Liu, Xianglin; Wang, Jiansong; Li, Zhihuai; Lü, Yongming

    2017-10-01

    To explore the effectiveness of the arthroscopic separate double-layer suture bridge technique in treatment of the delaminated rotator cuff tear. Between May 2013 and May 2015, 54 patients with the delaminated rotator cuff tears were recruited in the study. They were randomly allocated into 2 groups to receive repair either using arthroscopic separate double-layer suture bridge technique (trial group, n =28) or using arthroscopic whole-layer suture bridge technique (control group, n =26). There was no significant difference in gender, age, injured side, tear type, and preoperative visual analogue scale (VAS) score, Constants score, American Shoulder and Elbow Surgeons (ASES) score, University of California Los Angeles (UCLA) score, and the range of motion of shoulder joint between 2 groups ( P >0.05). Postoperative functional scores, range of motion, and recurrence rate of tear in 2 groups were observed and compared. The operation time was significant longer in trial group than in control group ( t =8.383, P =0.000). All incisions healed at stage Ⅰ without postoperative complication. All the patients were followed up 12 months. At 12 months postoperatively, the UCLA score, ASES score, VAS score, Constant score, and the range of motion were significantly improved when compared with the preoperative values in 2 groups ( P 0.05). Four cases (14.3%) of rotator cuff tear recurred in trial group while 5 cases (19.2%) in control group, showing no significant difference ( χ 2 =0.237, P =0.626). Compared with the arthroscopic whole-layer suture bridge technique, arthroscopic separate double-layer suture bridge technique presents no significant difference in the shoulder function score, the range of motion, and recurrence of rotator cuff tear, while having a longer operation time.

  17. Development of the high temperature ion-source for the Grenoble electromagnetic isotope separator

    Bouriant, M.

    1968-01-01

    The production of high purity stable or radioactive isotopes (≥ 99.99 per cent) using electromagnetic separation require for equipment having a high resolving power. Besides, and in order to collect rare or short half-life isotopes, the efficiency of the ion-source must be high (η > 5 to 10 per cent). With this in view, the source built operates at high temperatures (2500-3000 C) and makes use of ionisation by electronic bombardment or of thermo-ionisation. A summary is given in the first part of this work on the essential characteristics of the isotope separator ion Sources; a diagram of the principle of the source built is then given together with its characteristics. In the second part are given the values of the resolving power and of the efficiency of the Grenoble isotope separator fitted with such a source. The resolving power measured at 10 per cent of the peak height is of the order of 200. At the first magnetic stage the efficiency is between 1 and 26 per cent for a range of elements evaporating between 200 and 3000 C. Thus equipped, the separator has for example given, at the first stage, 10 mg of 180 Hf at (99.69 ± 0.1) per cent corresponding to an enrichment coefficient of 580; recently 2 mg of 150 Nd at (99.996 ± 0.002) per cent corresponding to an enrichment coefficient of 4.2 x 10 5 has been obtained at the second stage. (author) [fr

  18. Source reconstruction using phase space beam summation technique

    Graubart, Gideon.

    1990-10-01

    In this work, the phase-space beam summation technique (PSBS), is applied to back propagation and inverse source problems. The PSBS expresses the field as a superposition of shifted and tilted beams. This phase space spectrum of beams is matched to the source distribution via an amplitude function which expresses the local spectrum of the source function in terms of a local Fourier transform. In this work, the emphasis is on the phase space processing of the data, on the information content of this data and on the back propagation scheme. More work is still required to combine this back propagation approach in a full, multi experiment inverse scattering scheme. It is shown that the phase space distribution of the data, computed via the local spectrum transform, is localized along lines that define the local arrival direction of the wave data. We explore how the choice of the beam width affects the compactification of this distribution, and derive criteria for choosing a window that optimizes this distribution. It should be emphasized that compact distribution implies fewer beams in the back propagation scheme and therefore higher numerical efficiency and better physical insight. Furthermore it is shown how the local information property of the phase space representation can be used to improve the performance of this simple back propagation problem, in particular with regard to axial resolution; the distance to the source can be determined by back propagating only the large angle phase space beams that focus on the source. The information concerning transverse distribution of the source, on the other hand, is contained in the axial phase space region and can therefore be determined by the corresponding back propagating beams. Because of the global nature of the plane waves propagators the conventional plane wave back propagation scheme does not have the same 'focusing' property, and therefore suffers from lack of information localization and axial resolution. The

  19. Silver recovery aqueous techniques from diverse sources: Hydrometallurgy in recycling.

    Syed, S

    2016-04-01

    The demand of silver is ever increasing with the advance of the industrialized world, whereas worldwide reserves of high grade silver ores are retreating. However, there exist large stashes of low and lean grade silver ores that are yet to be exploited. The main impression of this work was to draw attention to the most advance technologies in silver recovery and recycling from various sources. The state of the art in recovery of silver from different sources by hydrometallurgical and bio-metallurgical processing and varieties of leaching, cementing, reducing agents, peeling, electro-coagulants, adsorbents, electro-dialysis, solvent extraction, ion exchange resins and bio sorbents are highlighted in this article. It is shown that the major economic driver for recycling of depleted sources is for the recovery of silver. In order to develop an nature-friendly technique for the recovery of silver from diverse sources, a critical comparison of existing technologies is analyzed for both economic viability and environmental impact was made in this amendment and silver ion toxicity is highlighted. Copyright © 2016 Elsevier Ltd. All rights reserved.

  20. New modes of particle accelerations techniques and sources. Formal report

    Parsa, Z.

    1996-01-01

    This Report includes copies of transparencies and notes from the presentations made at the Symposium on New Modes of Particle Accelerations - Techniques and Sources, August 19-23, 1996 at the Institute for Theoretical Physics, University of California, Santa Barbara California, that was made available by the authors. Editing, reduction and changes to the authors contributions were made only to fulfill the printing and publication requirements. We would like to take this opportunity and thank the speakers for their informative presentations and for providing copies of their transparencies and notes for inclusion in this Report

  1. New modes of particle accelerations techniques and sources. Formal report

    Parsa, Z. [ed.

    1996-12-31

    This Report includes copies of transparencies and notes from the presentations made at the Symposium on New Modes of Particle Accelerations - Techniques and Sources, August 19-23, 1996 at the Institute for Theoretical Physics, University of California, Santa Barbara California, that was made available by the authors. Editing, reduction and changes to the authors contributions were made only to fulfill the printing and publication requirements. We would like to take this opportunity and thank the speakers for their informative presentations and for providing copies of their transparencies and notes for inclusion in this Report.

  2. Pulse Sign Separation Technique for the Received Bits in Wireless Ultra-Wideband Combination Approach

    Rashid A. Fayadh

    2014-01-01

    Full Text Available When receiving high data rate in ultra-wideband (UWB technology, many users have experienced multiple-user interference and intersymbol interference in the multipath reception technique. Structures have been proposed for implementing rake receivers to enhance their capabilities by reducing the bit error probability (Pe, thereby providing better performances by indoor and outdoor multipath receivers. As a result, several rake structures have been proposed in the past to reduce the number of resolvable paths that must be estimated and combined. To achieve this aim, we suggest two maximal ratio combiners based on the pulse sign separation technique, such as the pulse sign separation selective combiner (PSS-SC and the pulse sign separation partial combiner (PSS-PC to reduce complexity with fewer fingers and to improve the system performance. In the combiners, a comparator was added to compare the positive quantity of positive pulses and negative quantities of negative pulses to decide whether the transmitted bit was 1 or 0. The Pe was driven by simulation for multipath environments for impulse radio time-hopping binary phase shift keying (TH-BPSK modulation, and the results were compared with those of conventional selective combiners (C-SCs and conventional partial combiners (C-PCs.

  3. Separation and analysis techniques for bound and unbound alkyl ketene dimer (AKD in paper: A review

    Sunil Kumar

    2016-11-01

    Full Text Available Alkyl ketene dimer (AKD is the reactive synthetic sizing agent that is used in alkaline or neutral papermaking conditions to provide certain level of hydrophobicity to the paper and board. The sizing mechanism of AKD involves its reaction with the hydroxyl groups on cellulose. However, all of AKD does not chemically react with fibers; some of it may undergo hydrolysis in water to form unstable β-keto acids, which decarboxylate to the corresponding ketone. This portion of AKD remains non-reacted (unbound and adsorbs onto fibers. The sizing effect depends mainly on the quantity of chemically reacted (bound AKD in paper, while the role of unbound forms, that is ketone and oligomer, is still not clear. Both bound and unbound portions of AKD have their own effect on paper. It is important to know the proportion of bound and unbound form of AKD in paper. The different techniques have been adopted for the separation and analysis of bound and unbound AKD present in paper. The aim of this paper is to review and summarize the various techniques provided by the researchers to separate the different forms of AKD and highlight the most important aspects for their separation.

  4. Recoil separators for radiative capture using radioactive ion beams. Recent advances and detection techniques

    Ruiz, Chris [TRIUMF, Vancouver, BC (Canada); Greife, Uwe; Hager, Ulrike [Colorado School of Mines, Golden, CO (United States)

    2014-06-15

    Radiative capture reactions involving the fusion of hydrogen or helium are ubiquitous in the stellar history of the universe, and are some of the most important reactions in the processes that govern nucleosynthesis and energy generation in both static and explosive scenarios. However, radiative capture reactions pose some of the most difficult experimental challenges due to extremely small cross sections. With the advent of recoil separators and techniques in inverse kinematics, it is now possible to measure radiative capture reactions on very short-lived radioactive nuclei, and in the presence of high experimental backgrounds. In this paper we review the experimental needs for making measurements of astrophysical importance on radiative capture reactions. We also review some of the important historical advances in the field of recoil separators as well as describe current techniques and performance milestones, including descriptions of some of the separators most recently working at radioactive ion beam facilities, such as DRAGON at TRIUMF and the DRS at the Holifield Radioactive Ion Beam Facility. We will also summarize some of the scientific highlight measurements at the RIB facilities. (orig.)

  5. Separation of simultaneous sources using a structural-oriented median filter in the flattened dimension

    Gan, Shuwei; Wang, Shoudong; Chen, Yangkang; Chen, Xiaohong; Xiang, Kui

    2016-01-01

    Simultaneous-source shooting can help tremendously shorten the acquisition period and improve the quality of seismic data for better subsalt seismic imaging, but at the expense of introducing strong interference (blending noise) to the acquired seismic data. We propose to use a structural-oriented median filter to attenuate the blending noise along the structural direction of seismic profiles. The principle of the proposed approach is to first flatten the seismic record in local spatial windows and then to apply a traditional median filter (MF) to the third flattened dimension. The key component of the proposed approach is the estimation of the local slope, which can be calculated by first scanning the NMO velocity and then transferring the velocity to the local slope. Both synthetic and field data examples show that the proposed approach can successfully separate the simultaneous-source data into individual sources. We provide an open-source toy example to better demonstratethe proposed methodology.

  6. Iterative algorithm for joint zero diagonalization with application in blind source separation.

    Zhang, Wei-Tao; Lou, Shun-Tian

    2011-07-01

    A new iterative algorithm for the nonunitary joint zero diagonalization of a set of matrices is proposed for blind source separation applications. On one hand, since the zero diagonalizer of the proposed algorithm is constructed iteratively by successive multiplications of an invertible matrix, the singular solutions that occur in the existing nonunitary iterative algorithms are naturally avoided. On the other hand, compared to the algebraic method for joint zero diagonalization, the proposed algorithm requires fewer matrices to be zero diagonalized to yield even better performance. The extension of the algorithm to the complex and nonsquare mixing cases is also addressed. Numerical simulations on both synthetic data and blind source separation using time-frequency distributions illustrate the performance of the algorithm and provide a comparison to the leading joint zero diagonalization schemes.

  7. A mathematical model for source separation of MMG signals recorded with a coupled microphone-accelerometer sensor pair.

    Silva, Jorge; Chau, Tom

    2005-09-01

    Recent advances in sensor technology for muscle activity monitoring have resulted in the development of a coupled microphone-accelerometer sensor pair for physiological acousti signal recording. This sensor can be used to eliminate interfering sources in practical settings where the contamination of an acoustic signal by ambient noise confounds detection but cannot be easily removed [e.g., mechanomyography (MMG), swallowing sounds, respiration, and heart sounds]. This paper presents a mathematical model for the coupled microphone-accelerometer vibration sensor pair, specifically applied to muscle activity monitoring (i.e., MMG) and noise discrimination in externally powered prostheses for below-elbow amputees. While the model provides a simple and reliable source separation technique for MMG signals, it can also be easily adapted to other aplications where the recording of low-frequency (< 1 kHz) physiological vibration signals is required.

  8. On suitability of novel fluidised bed technique for separation of metallic powders during commercial powder metallurgical processing

    Ritherdon, J; Dechsiri, C; Jones, AR; Hoffmann, AC; Wright, IG

    Experiments have been performed to test the efficiency with which a novel fluidised bed technique could separate different metallic powders in terms of size and density. The overall aim was to assess the potential of this technique for the commercial separation of defective powder fractions from

  9. Observation on the stability of the solid phase microparticles separating technique in T3, T4 radioimmunoassay

    Chen Guangliang; Chen Xunmin

    1995-01-01

    The solid phase T 3 ,T 4 RIA is adopted at various laboratories. The data analysis from the effective dose and quality control of samples indicates that the separation technique is of good effect and high stability. It is an effective separation technique for the quality control in RIA

  10. Estimation of Input Function from Dynamic PET Brain Data Using Bayesian Blind Source Separation

    Tichý, Ondřej; Šmídl, Václav

    2015-01-01

    Roč. 12, č. 4 (2015), s. 1273-1287 ISSN 1820-0214 R&D Projects: GA ČR GA13-29225S Institutional support: RVO:67985556 Keywords : blind source separation * Variational Bayes method * dynamic PET * input function * deconvolution Subject RIV: BB - Applied Statistics, Operational Research Impact factor: 0.623, year: 2015 http://library.utia.cas.cz/separaty/2015/AS/tichy-0450509.pdf

  11. Online Artifact Removal for Brain-Computer Interfaces Using Support Vector Machines and Blind Source Separation

    Halder, Sebastian; Bensch, Michael; Mellinger, Jürgen; Bogdan, Martin; Kübler, Andrea; Birbaumer, Niels; Rosenstiel, Wolfgang

    2007-01-01

    We propose a combination of blind source separation (BSS) and independent component analysis (ICA) (signal decomposition into artifacts and nonartifacts) with support vector machines (SVMs) (automatic classification) that are designed for online usage. In order to select a suitable BSS/ICA method, three ICA algorithms (JADE, Infomax, and FastICA) and one BSS algorithm (AMUSE) are evaluated to determine their ability to isolate electromyographic (EMG) and electrooculographic...

  12. Weight adjusted tensor method for blind separation of underdetermined mixtures of nonstationary sources

    Tichavský, Petr; Koldovský, Zbyněk

    2011-01-01

    Roč. 59, č. 3 (2011), s. 1037-1047 ISSN 1053-587X R&D Projects: GA MŠk 1M0572; GA ČR GA102/09/1278 Institutional research plan: CEZ:AV0Z10750506 Keywords : blind source separation * tensor decomposition * Cramer-Rao lower bound Subject RIV: BB - Applied Statistics, Operational Research Impact factor: 2.628, year: 2011 http://library.utia.cas.cz/separaty/2011/SI/tichavsky-0356666. pdf

  13. Phase separation temperatures of a liquid mixture: Dynamic light scattering technique

    Dangudom, K.; Wongtawatnugool, C.; Lacharojana, S.

    2010-01-01

    Light scattering intensity measurements and photon correlation spectroscopy (PCS) techniques were employed in an investigation of liquid-liquid phase separation behaviour of a mixture of cyclohexane and methanol at seven different compositions. It was found that, except for one composition (29% methanol), the temperature at which the scattering intensity was a maximum did not coincide with the one where the diffusion coefficient was a minimum, as would be for the case of a vapour-liquid system. The difference may be explained in terms of the local density fluctuation and the random walk problem responsible for the peak intensity and the minimum in the diffusion coefficient, respectively. The definition of phase separation temperature, as determined from diffusion process, was also proposed in this work.

  14. Rhythmic entrainment source separation: Optimizing analyses of neural responses to rhythmic sensory stimulation.

    Cohen, Michael X; Gulbinaite, Rasa

    2017-02-15

    Steady-state evoked potentials (SSEPs) are rhythmic brain responses to rhythmic sensory stimulation, and are often used to study perceptual and attentional processes. We present a data analysis method for maximizing the signal-to-noise ratio of the narrow-band steady-state response in the frequency and time-frequency domains. The method, termed rhythmic entrainment source separation (RESS), is based on denoising source separation approaches that take advantage of the simultaneous but differential projection of neural activity to multiple electrodes or sensors. Our approach is a combination and extension of existing multivariate source separation methods. We demonstrate that RESS performs well on both simulated and empirical data, and outperforms conventional SSEP analysis methods based on selecting electrodes with the strongest SSEP response, as well as several other linear spatial filters. We also discuss the potential confound of overfitting, whereby the filter captures noise in absence of a signal. Matlab scripts are available to replicate and extend our simulations and methods. We conclude with some practical advice for optimizing SSEP data analyses and interpreting the results. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. Ion source development for the on-line isotope separator at GSI

    Kirchner, R.; Burkard, K.; Hueller, W.; Klepper, O.

    1991-08-01

    The progress in the understanding of ion sources for isotope separation on-line and the feasibility of bunched beams of relatively refractory elements is reported. The ultra-high temperature FEBIAD-H ion source, facilitating the mounting of catchers and window compared to the earlier F-version, enables bunched beams of the elements with adsorption enthalpies up to almost 6 eV, e.g. of Be, Al, Ca, Cr, Fe, Co, Ni, Sr, Pd, Ba, Yb, and Au. This way also chemical selectivity for these elements may be achieved, at least to some extent, for isotopes with halflives > or approx.1 minute, including especially the difficult separation of alkaline-earth isotopes from isobaric alkalines. These studies reveal, however, also a principal difficulty in the on-line separation of refractory elements, namely their tendency, increasing with ΔH a , to re-diffuse after release from the catcher into the bulk of the hot source enclosure. (orig.)

  16. Concepts and Criteria for Blind Quantum Source Separation and Blind Quantum Process Tomography

    Alain Deville

    2017-07-01

    Full Text Available Blind Source Separation (BSS is an active domain of Classical Information Processing, with well-identified methods and applications. The development of Quantum Information Processing has made possible the appearance of Blind Quantum Source Separation (BQSS, with a recent extension towards Blind Quantum Process Tomography (BQPT. This article investigates the use of several fundamental quantum concepts in the BQSS context and establishes properties already used without justification in that context. It mainly considers a pair of electron spins initially separately prepared in a pure state and then submitted to an undesired exchange coupling between these spins. Some consequences of the existence of the entanglement phenomenon, and of the probabilistic aspect of quantum measurements, upon BQSS solutions, are discussed. An unentanglement criterion is established for the state of an arbitrary qubit pair, expressed first with probability amplitudes and secondly with probabilities. The interest of using the concept of a random quantum state in the BQSS context is presented. It is stressed that the concept of statistical independence of the sources, widely used in classical BSS, should be used with care in BQSS, and possibly replaced by some disentanglement principle. It is shown that the coefficients of the development of any qubit pair pure state over the states of an orthonormal basis can be expressed with the probabilities of results in the measurements of well-chosen spin components.

  17. An approach for evaluating the effects of source separation on municipal solid waste management

    Tanskanen, J.H. [Finnish Environment Institute, Helsinki (Finland)

    2000-07-01

    An approach was developed for integrated analysis of recovery rates, waste streams, costs and emissions of municipal solid waste management (MSWM). The approach differs from most earlier models used in the strategic planning of MSWM because of a comprehensive analysis of on-site collection systems of waste materials separated at source for recovery. As a result, the recovery rates and sizes of waste streams can be calculated on the basis of the characteristics of separation strategies instead of giving them as input data. The modelling concept developed can also be applied in other regions, municipalities and districts. This thesis consists of four case studies. Three of these were performed to test the approach developed and to evaluate the effects of separation on MSWM in Finland. In these case studies the approach was applied for modelling: (1) Finland's national separation strategy for municipal solid waste, (2) the effects of separation on MSWM systems in the Helsinki region and (3) the efficiency of various waste collection methods in the Helsinki region. The models developed for these three case studies are static and linear simulation models which were constructed in the format of an Excel spreadsheet. In addition, a new version of the original Swedish MIMES/Waste model was constructed and applied in one of the case studies. The case studies proved that the approach is an applicable tool for various research settings and circumstances in the strategic planning of MSWM. The following main results were obtained from the case studies: A high recovery rate level (around 70 %wt) can be achieved in MSWM without incineration; Central sorting of mixed waste must be included in Finland's national separation strategy in order to reach the recovery rate targets of 50 %wt (year 2000) and 70 %wt (year 2005) adopted for municipal solid waste in the National Waste Plan. The feasible source separation strategies result in recovery rates around 35-40 %wt with the

  18. Distributed Source Coding Techniques for Lossless Compression of Hyperspectral Images

    Barni Mauro

    2007-01-01

    Full Text Available This paper deals with the application of distributed source coding (DSC theory to remote sensing image compression. Although DSC exhibits a significant potential in many application fields, up till now the results obtained on real signals fall short of the theoretical bounds, and often impose additional system-level constraints. The objective of this paper is to assess the potential of DSC for lossless image compression carried out onboard a remote platform. We first provide a brief overview of DSC of correlated information sources. We then focus on onboard lossless image compression, and apply DSC techniques in order to reduce the complexity of the onboard encoder, at the expense of the decoder's, by exploiting the correlation of different bands of a hyperspectral dataset. Specifically, we propose two different compression schemes, one based on powerful binary error-correcting codes employed as source codes, and one based on simpler multilevel coset codes. The performance of both schemes is evaluated on a few AVIRIS scenes, and is compared with other state-of-the-art 2D and 3D coders. Both schemes turn out to achieve competitive compression performance, and one of them also has reduced complexity. Based on these results, we highlight the main issues that are still to be solved to further improve the performance of DSC-based remote sensing systems.

  19. Currents trends in the application of IBA techniques to air pollution source fingerprinting and source apportionment

    Cohen, David; Stelcer, Ed.; Atanacio, Armand; Crawford, Jagoda

    2013-01-01

    Full text: IBA techniques have been used for many years to characterise fine particle air pollution. This is not new the techniques are well established. Typically 2-3 MeV protons are used to bombard thin filter papers and up to four simultaneous techniques like PIXE, PIGE, RBS and ERDA will be applied to obtain (μg/g) concentrations for elements from hydrogen to lead. Generally low volume samplers are used to sample between 20-30 m 3 of air over a 24 hour period, this together with IBA's sensitivity means that concentrations down to 1 ng/m 3 of air sampled can be readily achieved with only a few minutes of proton irradiation. With these short irradiation times and low sensitivities for a broad range of elements in the periodic table, large numbers of samples can be obtained and analysed very quickly and easily. At ANSTO we have used IBA methods to acquire a database of over 50,000 filters from 85 different sites through Australia and Asia, each filter has been analysed for more than 21 different chemical species. Large databases extending over many years means that modern statistical techniques like positive matrix factorisation (PMF) can be used to define well characterised source fingerprints and source contributions for a range of different fine particle air pollutants. In this paper we will discuss these PMF techniques and show how they identify both natural sources like sea spray and windblown soils as well as anthropogenic sources like automobiles, biomass burning, coal-fired power stations and industrial emissions. These data are particularly useful for Governments, EPA's and managers of pollution to better understanding pollution sources and their relative contributions and hence to better manage air pollution. Current trends are to take these IBA and PMF techniques a step further and to combine them with wind speed and back trajectory data to better pin point and identify emission sources. We show how this is now being applied on both a local

  20. Currents trends in the application of IBA techniques to air pollution source fingerprinting and source apportionment

    Cohen, David; Stelcer, Ed.; Atanacio, Armand; Crawford, Jagoda [Australian Nuclear Science and Technology Organisation, Kirrawee DC (Australia)

    2013-07-01

    Full text: IBA techniques have been used for many years to characterise fine particle air pollution. This is not new the techniques are well established. Typically 2-3 MeV protons are used to bombard thin filter papers and up to four simultaneous techniques like PIXE, PIGE, RBS and ERDA will be applied to obtain (μg/g) concentrations for elements from hydrogen to lead. Generally low volume samplers are used to sample between 20-30 m{sup 3} of air over a 24 hour period, this together with IBA's sensitivity means that concentrations down to 1 ng/m{sup 3} of air sampled can be readily achieved with only a few minutes of proton irradiation. With these short irradiation times and low sensitivities for a broad range of elements in the periodic table, large numbers of samples can be obtained and analysed very quickly and easily. At ANSTO we have used IBA methods to acquire a database of over 50,000 filters from 85 different sites through Australia and Asia, each filter has been analysed for more than 21 different chemical species. Large databases extending over many years means that modern statistical techniques like positive matrix factorisation (PMF) can be used to define well characterised source fingerprints and source contributions for a range of different fine particle air pollutants. In this paper we will discuss these PMF techniques and show how they identify both natural sources like sea spray and windblown soils as well as anthropogenic sources like automobiles, biomass burning, coal-fired power stations and industrial emissions. These data are particularly useful for Governments, EPA's and managers of pollution to better understanding pollution sources and their relative contributions and hence to better manage air pollution. Current trends are to take these IBA and PMF techniques a step further and to combine them with wind speed and back trajectory data to better pin point and identify emission sources. We show how this is now being applied on both

  1. The use of a single technique for the separation and determination of actinides in biological materials

    Camera, V.; Giubileo.

    1975-01-01

    For the radiotoxicological survey of workers exposed to different types of alpha-emitting contaminants, a procedure was developed which permits the estimate of Th, Pa, U, Np, Pu, Am and Cm in biological samples with a single technique. The radionuclides are extracted on a column by tri-n-octylphosphine oxide and separated by elution at different pH values. Afterwards, the quantitative determinations are done by physical methods (alpha counting or spectrometry). In the case of an accident it is possible to use a simplification of the procedure (extraction in a beaker) for checks. A procedure for the rapid determination of actinides in faeces and in nasal secretions is described

  2. The application of IBA techniques to air pollution source fingerprinting and source apportionment

    Cohen, D.D., E-mail: dcz@ansto.gov.au; Stelcer, E.; Atanacio, A.; Crawford, J.

    2014-01-01

    IBA techniques have been used to measure elemental concentrations of more than 20 different elements found in fine particle (PM2.5) air pollution. These data together with their errors and minimum detectable limits were used in Positive Matrix Factorisation (PMF) analyses to quantitatively determine source fingerprints and their contributions to the total measured fine mass. Wind speed and direction back trajectory data from the global HYSPLIT codes were then linked to these PMF fingerprints to quantitatively identify the location of the sources.

  3. Application of physical separation techniques for waste utilization and management - case studies from Indian uranium deposits

    Anand Rao, K.; Sreenivas, T.

    2013-01-01

    The importance of physical beneficiation techniques in metallurgical industry showed gradual decline due to decreasing ore grades and very-fine size dissemination of valuable minerals in the host matrix. However, this technology regained prominence in recent past due to their utility in resource recycle, waste utilization, waste treatment and environmental remediation. Hybrid processes combined with physical, chemical and biological technology is now developing such that the idea of sustainable development is implemented. The uranium ore processing industry has always been under intense public scanner for some of the apprehensions, chiefly radioactivity, inspite of its immense energy delivering potential. Besides this, the chemical compounds formed due to gangue mineral reactivity and their carry-over to tailings pond added further owes. However, conscious scientific efforts are being made to contain these hazards to permissible levels by application of various remedial methods of which the physical separation techniques too are quite prominent

  4. A chemically selective laser ion source for the on-line isotope separation

    Scheerer, F.

    1993-03-01

    In this thesis a laser ion source is presented. In a hot chamber the atoms of the elements to be studied are resonantly by light of pulsed dye lasers, which are pumped by pulsed copper-vapor lasers with extremely high pulse repetition rate (ν rep ∼ 10 kHz), stepwise excited and ionized. By the storage of the atoms in a hot chamber and the high pulse repetition rate of the copper-vapor lasers beyond the required high efficiency (ε ∼ 10%) can be reached. First preparing measurements were performed at the off-line separator at CERN with the rare earth elements ytterbium and thulium. Starting from the results of these measurements further tests of the laser ion source were performed at the on-line separator with in a thick tantalum target produced neutron-deficient ytterbium isotopes. Under application of a time-of-flight mass spectrometer in Mainz an efficient excitation scheme on the resonance ionization of tin was found. This excitation scheme is condition for an experiment at the GSI for the production of the extremely neutron-deficient, short-lived nucleus 102 Sn. In the summer 1993 is as first application of the newly developed laser ion source at the PSB-ISOLDE at CERN an astrophysically relevant experiment for the nuclear spectroscopy of the neutron-rich silver isotopes 124-129 Ag is planned. This experiment can because of the lacking selectivity of conventional ion sources only be performed by means of the here presented laser ion source. The laser ion source shall at the PSB-ISOLDE 1993 also be applied for the selective ionization of manganese. (orig./HSI) [de

  5. Resonance ionization laser ion sources for on-line isotope separators (invited)

    Marsh, B. A.

    2014-01-01

    A Resonance Ionization Laser Ion Source (RILIS) is today considered an essential component of the majority of Isotope Separator On Line (ISOL) facilities; there are seven laser ion sources currently operational at ISOL facilities worldwide and several more are under development. The ionization mechanism is a highly element selective multi-step resonance photo-absorption process that requires a specifically tailored laser configuration for each chemical element. For some isotopes, isomer selective ionization may even be achieved by exploiting the differences in hyperfine structures of an atomic transition for different nuclear spin states. For many radioactive ion beam experiments, laser resonance ionization is the only means of achieving an acceptable level of beam purity without compromising isotope yield. Furthermore, by performing element selection at the location of the ion source, the propagation of unwanted radioactivity downstream of the target assembly is reduced. Whilst advances in laser technology have improved the performance and reliability of laser ion sources and broadened the range of suitable commercially available laser systems, many recent developments have focused rather on the laser/atom interaction region in the quest for increased selectivity and/or improved spectral resolution. Much of the progress in this area has been achieved by decoupling the laser ionization from competing ionization processes through the use of a laser/atom interaction region that is physically separated from the target chamber. A new application of gas catcher laser ion source technology promises to expand the capabilities of projectile fragmentation facilities through the conversion of otherwise discarded reaction fragments into high-purity low-energy ion beams. A summary of recent RILIS developments and the current status of laser ion sources worldwide is presented

  6. Generation of dynamo waves by spatially separated sources in the Earth and other celestial bodies

    Popova, E.

    2017-12-01

    The amplitude and the spatial configuration of the planetary and stellar magnetic field can changing over the years. Celestial bodies can have cyclic, chaotic or unchanging in time magnetic activity which is connected with a dynamo mechanism. This mechanism is based on the consideration of the joint influence of the alpha-effect and differential rotation. Dynamo sources can be located at different depths (active layers) of the celestial body and can have different intensities. Application of this concept allows us to get different forms of solutions and some of which can include wave propagating inside the celestial body. We analytically showed that in the case of spatially separated sources of magnetic field each source generates a wave whose frequency depends on the physical parameters of its source. We estimated parameters of sources required for the generation nondecaying waves. We discus structure of such sources and matter motion (including meridional circulation) in the liquid outer core of the Earth and active layers of other celestial bodies.

  7. Investigation of gas discharge ion sources for on-line mass separation

    Kirchner, R.

    1976-03-01

    The development of efficient gas discharge ion sources with axial beam extraction for on-line mass separation is described. The aim of the investigation was to increase the ion source temperature, the lifetime and the ionisation yield in comparison to present low-pressure are discharge ion sources and to reduce the ion current density from usually 1 to 100 mA/cm 3 . In all ion sources the pressure range below the minimal ignition pressure of the arc discharge was investigated. As a result an ion source was developed which works at small changes in geometry and in electric device of a Nielsen source with high ionization yield (up to 50% for xenon) stabil and without ignition difficulties up to 10 -5 Torr. At a typical pressure of 3 x 10 -5 Torr ion current and ion current density are about 1 μA and 0.1 mA/cm 3 respectively besides high yield and a great emission aperture (diameter 1.2 mm). (orig.) [de

  8. Waste water purification by magnetic separation technique using HTS bulk magnet system

    Oka, T.; Kanayama, H.; Tanaka, K.; Fukui, S.; Ogawa, J.; Sato, T.; Ooizumi, M.; Terasawa, T.; Itoh, Y.; Yabuno, R.

    2009-01-01

    We have investigated the feasibility of strong magnetic field generators composed of the high temperature superconducting (HTS) bulk magnet systems to the magnetic separation techniques for the waste water including thin emulsion bearing the cutting oil. Two types of the strong field generators were prepared by the face-to-face HTS bulk magnet systems, which emit the magnetic field density of 1 and 2 T in the open spaces between the magnetic poles activated by the pulsed field magnetization and the field cooling methods, respectively. A couple of water channels containing iron balls were settled in the strong field to trap the magnetized flocks in the waste water. The separation ratios of flocks containing 200 ppm magnetite powder were evaluated with respect to the flow rates of the waste water. The performances of bulk magnet system have kept showing values of around 100% until the flowing rate reached up to 18 l/min. This suggests that the magnetic separation by using bulk magnets is effective for the practical water purification systems.

  9. Separation of Poly(styrene-block-t-butyl methacrylate) Copolymers by Various Liquid Chromatography Techniques

    Šmigovec Ljubič, Tina; Pahovnik, David; Žigon, Majda; Žagar, Ema

    2012-01-01

    The separation of a mixture of three poly(styrene-block-t-butyl methacrylate) copolymers (PS-b-PtBMA), consisting of polystyrene (PS) blocks of similar length and t-butyl methacrylate (PtBMA) blocks of different lengths, was performed using various chromatographic techniques, that is, a gradient liquid chromatography on reversed-phase (C18 and C8) and normal-phase columns, a liquid chromatography under critical conditions for polystyrene as well as a fully automated two-dimensional liquid chromatography that separates block copolymers by chemical composition in the first dimension and by molar mass in the second dimension. The results show that a partial separation of the mixture of PS-b-PtBMA copolymers can be achieved only by gradient liquid chromatography on reversed-phase columns. The coelution of the two block copolymers is ascribed to a much shorter PtBMA block length, compared to the PS block, as well as a small difference in the length of the PtBMA block in two of these copolymers, which was confirmed by SEC-MALS and NMR spectroscopy. PMID:22489207

  10. Industrial scale production of stable isotopes employing the technique of plasma separation

    Stevenson, N.R.; Bigelow, T.S.; Tarallo, F.J.

    2003-01-01

    Calutrons, centrifuges, diffusion and distillation processes are some of the devices and techniques that have been employed to produce substantial quantities of enriched stable isotopes. Nevertheless, the availability of enriched isotopes in sufficient quantities for industrial applications remains very restricted. Industries such as those involved with medicine, semiconductors, nuclear fuel, propulsion, and national defense have identified the potential need for various enriched isotopes in large quantities. Economically producing most enriched (non-gaseous) isotopes in sufficient quantities has so far eluded commercial producers. The plasma separation process is a commercial technique now available for producing large quantities of a wide range of enriched isotopes. Until recently, this technique has mainly been explored with small-scale ('proof-of-principle') devices that have been built and operated at research institutes. The new Theragenics TM facility at Oak Ridge, TN houses the only existing commercial scale PSP system. This device, which successfully operated in the 1980's, has recently been re-commissioned and is planned to be used to produce a variety of isotopes. Progress and the capabilities of this device and it's potential for impacting the world's supply of stable isotopes in the future is summarized. This technique now holds promise of being able to open the door to allowing new and exciting applications of these isotopes in the future. (author)

  11. Separation of individual lanthanides through the combined techniques of urea fractionated homogeneous precipitation and ion exchange

    Umeda, K; Abrao, A

    1975-06-01

    The separation of individual lanthanides, especially Ce, Nd, Pr, Sm and La, from a rare earth chlorides concentrate by the industrial processing of monazite sand is made. To reach this goal the homogeneous fractional precipitation and ion exchange techniques were combined. Using the rare earths concentrate depleted in Cerium, fractions enriched in Nd, Pr and Sm, and one final filtrate enriched in La were obtained, by the hydrolysis of urea. The separation of individual lanthanides (Nd, Pr, Sm and La) was accomplished using two strong cationic ion exchanger columns, the second with Cu(II) as retaining ion, and EDTA-NH/sub 4/ solution buffered with acetic acid as eluant. The annoying problem of precipitation into the column during the RE elution was solved. The difficult EDTA and Cu(II) recovery was the precipitation of Cu/sub 2/S and disruption of Cu-EDTA complex by hydrolysis of thiourea. The combination of both techniques allowed the preparation of individual lanthanides as Nd, Pr and La with 99% and Sm with 90% purity.

  12. Separation of individual lanthanides through the combined techniques of urea fractionated homogeneous precipitation and ion exchange

    Umeda, K.; Abrao, A.

    1975-01-01

    The separation of individual lanthanides, especially Ce, Nd, Pr, Sm and La, from a rare earth chlorides concentrate by the industrial processing of monazite sand is made. To reach this goal the homogeneous fractional precipitation and ion exchange techniques were combined. Using the rare earths concentrate depleted in Cerium, fractions enriched in Nd, Pr and Sm, and one final filtrate enriched in La were obtained, by the hydrolysis of urea. The separation of individual lanthanides (Ns, Pr, Sm and La) was accomplished using two strong cationic ion exchanger columns, the second with Cu(II) as retaining ion, and EDTA-NH 4 solution buffered with acetic acid as eluant. The annoy problem of precipitation into the column during the RE elution was solved. The difficult EDTA and Cu(II) recovery was the precipitation of Cu 2 S and disruption of CU-EDTA complex by hydrolysis of thiourea. The combination of both techniques allowed the preparation of individual lanthanides as Nd, Pr and La with 99% and Sm with 90% purity

  13. On the Active and Passive Flow Separation Control Techniques over Airfoils

    Moghaddam, Tohid; Banazadeh Neishabouri, Nafiseh

    2017-10-01

    In the present work, recent advances in the field of the active and passive flow separation control, particularly blowing and suction flow control techniques, applied on the common airfoils are briefly reviewed. This broad research area has remained the point of interest for many years as it is applicable to various applications. The suction and blowing flow control methods, among other methods, are more technically feasible and market ready techniques. It is well established that the uniform and/or oscillatory blowing and suction flow control mechanisms significantly improve the lift-to-drag ratio, and further, postpone the boundary layer separation as well as the stall. The oscillatory blowing and suction flow control, however, is more efficient compared to the uniform one. A wide range of parameters is involved in controlling the behavior of a blowing and/or suction flow control, including the location, length, and angle of the jet slots. The oscillation range of the jet slot is another substantial parameter.

  14. Near-Field Source Localization by Using Focusing Technique

    He, Hongyang; Wang, Yide; Saillard, Joseph

    2008-12-01

    We discuss two fast algorithms to localize multiple sources in near field. The symmetry-based method proposed by Zhi and Chia (2007) is first improved by implementing a search-free procedure for the reduction of computation cost. We present then a focusing-based method which does not require symmetric array configuration. By using focusing technique, the near-field signal model is transformed into a model possessing the same structure as in the far-field situation, which allows the bearing estimation with the well-studied far-field methods. With the estimated bearing, the range estimation of each source is consequently obtained by using 1D MUSIC method without parameter pairing. The performance of the improved symmetry-based method and the proposed focusing-based method is compared by Monte Carlo simulations and with Crammer-Rao bound as well. Unlike other near-field algorithms, these two approaches require neither high-computation cost nor high-order statistics.

  15. Near-Field Source Localization by Using Focusing Technique

    Joseph Saillard

    2008-12-01

    Full Text Available We discuss two fast algorithms to localize multiple sources in near field. The symmetry-based method proposed by Zhi and Chia (2007 is first improved by implementing a search-free procedure for the reduction of computation cost. We present then a focusing-based method which does not require symmetric array configuration. By using focusing technique, the near-field signal model is transformed into a model possessing the same structure as in the far-field situation, which allows the bearing estimation with the well-studied far-field methods. With the estimated bearing, the range estimation of each source is consequently obtained by using 1D MUSIC method without parameter pairing. The performance of the improved symmetry-based method and the proposed focusing-based method is compared by Monte Carlo simulations and with Crammer-Rao bound as well. Unlike other near-field algorithms, these two approaches require neither high-computation cost nor high-order statistics

  16. PWC-ICA: A Method for Stationary Ordered Blind Source Separation with Application to EEG

    Bigdely-Shamlo, Nima; Mullen, Tim; Robbins, Kay

    2016-01-01

    Independent component analysis (ICA) is a class of algorithms widely applied to separate sources in EEG data. Most ICA approaches use optimization criteria derived from temporal statistical independence and are invariant with respect to the actual ordering of individual observations. We propose a method of mapping real signals into a complex vector space that takes into account the temporal order of signals and enforces certain mixing stationarity constraints. The resulting procedure, which we call Pairwise Complex Independent Component Analysis (PWC-ICA), performs the ICA in a complex setting and then reinterprets the results in the original observation space. We examine the performance of our candidate approach relative to several existing ICA algorithms for the blind source separation (BSS) problem on both real and simulated EEG data. On simulated data, PWC-ICA is often capable of achieving a better solution to the BSS problem than AMICA, Extended Infomax, or FastICA. On real data, the dipole interpretations of the BSS solutions discovered by PWC-ICA are physically plausible, are competitive with existing ICA approaches, and may represent sources undiscovered by other ICA methods. In conjunction with this paper, the authors have released a MATLAB toolbox that performs PWC-ICA on real, vector-valued signals. PMID:27340397

  17. PWC-ICA: A Method for Stationary Ordered Blind Source Separation with Application to EEG.

    Ball, Kenneth; Bigdely-Shamlo, Nima; Mullen, Tim; Robbins, Kay

    2016-01-01

    Independent component analysis (ICA) is a class of algorithms widely applied to separate sources in EEG data. Most ICA approaches use optimization criteria derived from temporal statistical independence and are invariant with respect to the actual ordering of individual observations. We propose a method of mapping real signals into a complex vector space that takes into account the temporal order of signals and enforces certain mixing stationarity constraints. The resulting procedure, which we call Pairwise Complex Independent Component Analysis (PWC-ICA), performs the ICA in a complex setting and then reinterprets the results in the original observation space. We examine the performance of our candidate approach relative to several existing ICA algorithms for the blind source separation (BSS) problem on both real and simulated EEG data. On simulated data, PWC-ICA is often capable of achieving a better solution to the BSS problem than AMICA, Extended Infomax, or FastICA. On real data, the dipole interpretations of the BSS solutions discovered by PWC-ICA are physically plausible, are competitive with existing ICA approaches, and may represent sources undiscovered by other ICA methods. In conjunction with this paper, the authors have released a MATLAB toolbox that performs PWC-ICA on real, vector-valued signals.

  18. PSFGAN: a generative adversarial network system for separating quasar point sources and host galaxy light

    Stark, Dominic; Launet, Barthelemy; Schawinski, Kevin; Zhang, Ce; Koss, Michael; Turp, M. Dennis; Sartori, Lia F.; Zhang, Hantian; Chen, Yiru; Weigel, Anna K.

    2018-06-01

    The study of unobscured active galactic nuclei (AGN) and quasars depends on the reliable decomposition of the light from the AGN point source and the extended host galaxy light. The problem is typically approached using parametric fitting routines using separate models for the host galaxy and the point spread function (PSF). We present a new approach using a Generative Adversarial Network (GAN) trained on galaxy images. We test the method using Sloan Digital Sky Survey r-band images with artificial AGN point sources added that are then removed using the GAN and with parametric methods using GALFIT. When the AGN point source is more than twice as bright as the host galaxy, we find that our method, PSFGAN, can recover point source and host galaxy magnitudes with smaller systematic error and a lower average scatter (49 per cent). PSFGAN is more tolerant to poor knowledge of the PSF than parametric methods. Our tests show that PSFGAN is robust against a broadening in the PSF width of ± 50 per cent if it is trained on multiple PSFs. We demonstrate that while a matched training set does improve performance, we can still subtract point sources using a PSFGAN trained on non-astronomical images. While initial training is computationally expensive, evaluating PSFGAN on data is more than 40 times faster than GALFIT fitting two components. Finally, PSFGAN is more robust and easy to use than parametric methods as it requires no input parameters.

  19. Application of resin in pulp technique for ion exchange separation of uranium from alkaline leachate

    Sreenivas, T.; Rajan, K.; Chakravorty, J.

    2014-01-01

    The hydrometallurgical process for the recovery of uranium from different ores uses ion exchange (IX) technique for the separation of dissolved uranium values. Conventionally, the IX process is carried out on leach solution obtained after the filtration or counter-current decantation of the leach slurries. Amongst the two types of leach pulps generated in uranium ore processing, viz acidic and alkaline, the latter one consists of predominantly fine-size pulps of higher viscosity, thus making the solid-liquid separation an arduous task. Sustained research for improvising the efficiency of various unit operations in the uranium process flowsheet have resulted in advent of new generation resins which are mechanically re-silent, posses higher exchange capacity thereby enabling separation of dissolved uranium ions from the leach pulps directly. Some of the prominent low-grade uranium ore deposits in India are hosted in acid consuming gangue matrix. These ore deposits necessitate fine grinding as well as application of alkaline leaching for the dissolution of uranium values. The leach pulps analyse 500 – 600 mg/l of U3O8 and contain total dissolved solutes (TDS) to the extent of about 50 g/l. Analysis of the characteristics of the leach pulp indicated suitability of resin-in-pulp technique for the separation of uranyl carbonate anions from the leachate. This paper describes the results of the RIP test work on alkaline leach slurry using various commercially available strong base anionic exchange resins. Parametric variation studies were conducted to establish the adsorption isotherm and sorption kinetics followed by elution of loaded uranium. Based on these results semi-continuous experiments on “carousel” mode were carried out. The results indicate superiority of gel type polystyrene based resins grafted with quaternary ammonium ion in comparison to the macro-porous resins. Semi-continuous counter-current extraction and elution tests indicated that about 98% of

  20. CO2 emission factors for waste incineration: Influence from source separation of recyclable materials

    Larsen, Anna Warberg; Astrup, Thomas

    2011-01-01

    variations between emission factors for different incinerators, but the background for these variations has not been thoroughly examined. One important reason may be variations in collection of recyclable materials as source separation alters the composition of the residual waste incinerated. The objective...... routed to incineration. Emission factors ranged from 27 to 40kg CO2/GJ. The results appeared most sensitive towards variations in waste composition and water content. Recycling rates and lower heating values could not be used as simple indicators of the resulting emission factors for residual household...... different studies and when using the values for environmental assessment purposes....

  1. In vivo time-gated diffuse correlation spectroscopy at quasi-null source-detector separation.

    Pagliazzi, M; Sekar, S Konugolu Venkata; Di Sieno, L; Colombo, L; Durduran, T; Contini, D; Torricelli, A; Pifferi, A; Mora, A Dalla

    2018-06-01

    We demonstrate time domain diffuse correlation spectroscopy at quasi-null source-detector separation by using a fast time-gated single-photon avalanche diode without the need of time-tagging electronics. This approach allows for increased photon collection, simplified real-time instrumentation, and reduced probe dimensions. Depth discriminating, quasi-null distance measurement of blood flow in a human subject is presented. We envision the miniaturization and integration of matrices of optical sensors of increased spatial resolution and the enhancement of the contrast of local blood flow changes.

  2. Light mesons and separated J(PC) sources in N-antiN annihilations at rest

    Lucaci-Timoce, Angela; Lazanu, I.

    2002-01-01

    N-antiN annihilations at rest and in flight are the most productive physics tools to investigate the spectroscopy of light mesons. The annihilations proceed from more sources of initial states, with different J (PC) quantum numbers. This makes the interpretation of the experimental data much more difficult than in the case of other annihilation process, as for example the e + e - annihilations, and introduces ambiguities in the results. In this talk, the possibilities to separate the N-antiN contributions of initial quantum states in different annihilation channels, are analyzed. The interference phenomena that appear are also discussed. (authors)

  3. Neutron/gamma dose separation by the multiple-ion-chamber technique

    Goetsch, S.J.

    1983-01-01

    Many mixed n/γ dosimetry systems rely on two dosimeters, one composed of a tissue-equivalent material and the other made from a non-hydrogenous material. The paired chamber technique works well in fields of neutron radiation nearly identical in spectral composition to that in which the dosimeters were calibrated. However, this technique is drastically compromised in phantom due to the degradation of the neutron spectrum. The three-dosimeter technique allows for the fall-off in neutron sensitivity of the two non-hydrogenous dosimeters. Precise and physically meaningful results were obtained with this technique with a D-T source in air and in phantom and with simultaneous D-T neutron and 60 Co gamma ray irradiation in air. The MORSE-CG coupled n/γ three-dimensional Monte Carlo code was employed to calculate neutron and gamma doses in a water phantom. Gamma doses calculated in phantom with this code were generally lower than corresponding ion chamber measurements. This can be explained by the departure of irradiation conditions from ideal narrow-beam geometry. 97 references

  4. Zeta potential of microfluidic substrates: 1. Theory, experimental techniques, and effects on separations.

    Kirby, Brian J; Hasselbrink, Ernest F

    2004-01-01

    This paper summarizes theory, experimental techniques, and the reported data pertaining to the zeta potential of silica and silicon with attention to use as microfluidic substrate materials, particularly for microchip chemical separations. Dependence on cation concentration, buffer and cation type, pH, cation valency, and temperature are discussed. The Debye-Hückel limit, which is often correctly treated as a good approximation for describing the ion concentration in the double layer, can lead to serious errors if it is extended to predict the dependence of zeta potential on the counterion concentration. For indifferent univalent electrolytes (e.g., sodium and potassium), two simple scalings for the dependence of zeta potential on counterion concentration can be derived in high- and low-zeta limits of the nonlinear Poisson-Boltzman equation solution in the double layer. It is shown that for most situations relevant to microchip separations, the high-zeta limit is most applicable, leading to the conclusion that the zeta potential on silica substrates is approximately proportional to the logarithm of the molar counterion concentration. The zeta vs. pH dependence measurements from several experiments are compared by normalizing the zeta based on concentration.

  5. Effect of temperature on acid–base equilibria in separation techniques. A review

    Gagliardi, Leonardo G.; Tascon, Marcos; Castells, Cecilia B.

    2015-01-01

    Studies on the theoretical principles of acid–base equilibria are reviewed and the influence of temperature on secondary chemical equilibria within the context of separation techniques, in water and also in aqueous-organic solvent mixtures, is discussed. In order to define the relationships between the retention in liquid chromatography or the migration velocity in capillary electrophoresis and temperature, the main properties of acid–base equilibria have to be taken into account for both, the analytes and the conjugate pairs chosen to control the solution pH. The focus of this review is based on liquid–liquid extraction (LLE), liquid chromatography (LC) and capillary electrophoresis (CE), with emphasis on the use of temperature as a useful variable to modify selectivity on a predictable basis. Simplified models were evaluated to achieve practical optimizations involving pH and temperature (in LLE and CE) as well as solvent composition in reversed-phase LC. - Highlights: • The study of theoretical principles of acid–base equilibrium has been reviewed. • The proton transfer process is often present in the analytical separation practice. • The influence of temperature on secondary chemical equilibria is examined. • The focus is laid on liquid chromatography and capillary electrophoresis. • Temperature can be a useful variable to modify selectivity under predictable basis

  6. PSFGAN: a generative adversarial network system for separating quasar point sources and host galaxy light

    Stark, Dominic; Launet, Barthelemy; Schawinski, Kevin; Zhang, Ce; Koss, Michael; Turp, M. Dennis; Sartori, Lia F.; Zhang, Hantian; Chen, Yiru; Weigel, Anna K.

    2018-03-01

    The study of unobscured active galactic nuclei (AGN) and quasars depends on the reliable decomposition of the light from the AGN point source and the extended host galaxy light. The problem is typically approached using parametric fitting routines using separate models for the host galaxy and the point spread function (PSF). We present a new approach using a Generative Adversarial Network (GAN) trained on galaxy images. We test the method using Sloan Digital Sky Survey (SDSS) r-band images with artificial AGN point sources added which are then removed using the GAN and with parametric methods using GALFIT. When the AGN point source PS is more than twice as bright as the host galaxy, we find that our method, PSFGAN, can recover PS and host galaxy magnitudes with smaller systematic error and a lower average scatter (49%). PSFGAN is more tolerant to poor knowledge of the PSF than parametric methods. Our tests show that PSFGAN is robust against a broadening in the PSF width of ±50% if it is trained on multiple PSF's. We demonstrate that while a matched training set does improve performance, we can still subtract point sources using a PSFGAN trained on non-astronomical images. While initial training is computationally expensive, evaluating PSFGAN on data is more than 40 times faster than GALFIT fitting two components. Finally, PSFGAN it is more robust and easy to use than parametric methods as it requires no input parameters.

  7. Sources of variability among replicate samples separated by two-dimensional gel electrophoresis.

    Bland, Alison M; Janech, Michael G; Almeida, Jonas S; Arthur, John M

    2010-04-01

    Two-dimensional gel electrophoresis (2DE) offers high-resolution separation for intact proteins. However, variability in the appearance of spots can limit the ability to identify true differences between conditions. Variability can occur at a number of levels. Individual samples can differ because of biological variability. Technical variability can occur during protein extraction, processing, or storage. Another potential source of variability occurs during analysis of the gels and is not a result of any of the causes of variability named above. We performed a study designed to focus only on the variability caused by analysis. We separated three aliquots of rat left ventricle and analyzed differences in protein abundance on the replicate 2D gels. As the samples loaded on each gel were identical, differences in protein abundance are caused by variability in separation or interpretation of the gels. Protein spots were compared across gels by quantile values to determine differences. Fourteen percent of spots had a maximum difference in intensity of 0.4 quantile values or more between replicates. We then looked individually at the spots to determine the cause of differences between the measured intensities. Reasons for differences were: failure to identify a spot (59%), differences in spot boundaries (13%), difference in the peak height (6%), and a combination of these factors (21). This study demonstrates that spot identification and characterization make major contributions to variability seen with 2DE. Methods to highlight why measured protein spot abundance is different could reduce these errors.

  8. Blind Source Separation and Dynamic Fuzzy Neural Network for Fault Diagnosis in Machines

    Huang, Haifeng; Ouyang, Huajiang; Gao, Hongli

    2015-01-01

    Many assessment and detection methods are used to diagnose faults in machines. High accuracy in fault detection and diagnosis can be achieved by using numerical methods with noise-resistant properties. However, to some extent, noise always exists in measured data on real machines, which affects the identification results, especially in the diagnosis of early- stage faults. In view of this situation, a damage assessment method based on blind source separation and dynamic fuzzy neural network (DFNN) is presented to diagnose the early-stage machinery faults in this paper. In the processing of measurement signals, blind source separation is adopted to reduce noise. Then sensitive features of these faults are obtained by extracting low dimensional manifold characteristics from the signals. The model for fault diagnosis is established based on DFNN. Furthermore, on-line computation is accelerated by means of compressed sensing. Numerical vibration signals of ball screw fault modes are processed on the model for mechanical fault diagnosis and the results are in good agreement with the actual condition even at the early stage of fault development. This detection method is very useful in practice and feasible for early-stage fault diagnosis. (paper)

  9. A system for routine production of 99mTc by thermal separation technique

    Sahm, U.; Helus, F.; Krauss, O.; Baier-Borst, W.

    1976-01-01

    Technetium-99m is one of the most widely used radionuclides in diagnostic medicine, and it is a general opinion that 99m Tc and the radiopharmaceuticals obtained from it will be used for a long time. 99m Tc has convenient physical and biological parameters for clinical applications. 99m Tc is formed by the beta decay from its 99 Mo parent. 99 Mo is produced by neutron irradiation of natural Mo or enriched 98 Mo, or as a fission product of 235 U. A third approach is cyclotron production of 99 Mo by proton bombardment of enriched 100 Mo over 100 Mo(p,pn) 99 Mo reaction. The most common method of separating 99m Tc from its 99 Mo parent is the elution of 99m Tc with normal saline from an aluminum oxide column containing adsorbed 99 Mo. The second method is solvent extraction using methylethylketon. The sublimation method is based on different volatility of MoO 3 and Tc 2 O 7 . Previously the development of a practical sublimation generator has been studied and some of them have been used routinely. As a reactor and cyclotron owner we have examined the possibility of producing our own 99m Tc with the aim of being independent from supplier and transportation problems. We have studied the separation of 99m Tc with the aim of being independent from supplier and transportation problems. We have studied the separation of 99m Tc from MoO 3 by complete distillation of gram amounts of natural MoO 3 or enriched 98 MoO 3 irradiated in reactor. The principle of the described method is based on the complete evaporation of MoO 3 and Tc 2 O 7 oxides and its following fractionated condensation. To realize this idea, two different generator systems for repeated multiple separation were developed and studied. The first based on using a two-oven technique. A quartz apparatus is placed in two ovens which are situated side by side and heated to different temperatures. Sweeping gas carries irradiated 99 MoO 3 from a middle part of the first oven heated to a higher temperature (1100 deg. C

  10. Fate of pharmaceuticals in full-scale source separated sanitation system.

    Butkovskyi, A; Hernandez Leal, L; Rijnaarts, H H M; Zeeman, G

    2015-11-15

    Removal of 14 pharmaceuticals and 3 of their transformation products was studied in a full-scale source separated sanitation system with separate collection and treatment of black water and grey water. Black water is treated in an up-flow anaerobic sludge blanket (UASB) reactor followed by oxygen-limited autotrophic nitrification-denitrification in a rotating biological contactor and struvite precipitation. Grey water is treated in an aerobic activated sludge process. Concentration of 10 pharmaceuticals and 2 transformation products in black water ranged between low μg/l to low mg/l. Additionally, 5 pharmaceuticals were also present in grey water in low μg/l range. Pharmaceutical influent loads were distributed over two streams, i.e. diclofenac was present for 70% in grey water, while the other compounds were predominantly associated to black water. Removal in the UASB reactor fed with black water exceeded 70% for 9 pharmaceuticals out of the 12 detected, with only two pharmaceuticals removed by sorption to sludge. Ibuprofen and the transformation product of naproxen, desmethylnaproxen, were removed in the rotating biological contactor. In contrast, only paracetamol removal exceeded 90% in the grey water treatment system while removal of other 7 pharmaceuticals was below 40% or even negative. The efficiency of pharmaceutical removal in the source separated sanitation system was compared with removal in the conventional sewage treatment plants. Furthermore, effluent concentrations of black water and grey water treatment systems were compared with predicted no-effect concentrations to assess toxicity of the effluent. Concentrations of diclofenac, ibuprofen and oxazepam in both effluents were higher than predicted no-effect concentrations, indicating the necessity of post-treatment. Ciprofloxacin, metoprolol and propranolol were found in UASB sludge in μg/g range, while pharmaceutical concentrations in struvite did not exceed the detection limits. Copyright © 2015

  11. Source-based neurofeedback methods using EEG recordings: training altered brain activity in a functional brain source derived from blind source separation

    White, David J.; Congedo, Marco; Ciorciari, Joseph

    2014-01-01

    A developing literature explores the use of neurofeedback in the treatment of a range of clinical conditions, particularly ADHD and epilepsy, whilst neurofeedback also provides an experimental tool for studying the functional significance of endogenous brain activity. A critical component of any neurofeedback method is the underlying physiological signal which forms the basis for the feedback. While the past decade has seen the emergence of fMRI-based protocols training spatially confined BOLD activity, traditional neurofeedback has utilized a small number of electrode sites on the scalp. As scalp EEG at a given electrode site reflects a linear mixture of activity from multiple brain sources and artifacts, efforts to successfully acquire some level of control over the signal may be confounded by these extraneous sources. Further, in the event of successful training, these traditional neurofeedback methods are likely influencing multiple brain regions and processes. The present work describes the use of source-based signal processing methods in EEG neurofeedback. The feasibility and potential utility of such methods were explored in an experiment training increased theta oscillatory activity in a source derived from Blind Source Separation (BSS) of EEG data obtained during completion of a complex cognitive task (spatial navigation). Learned increases in theta activity were observed in two of the four participants to complete 20 sessions of neurofeedback targeting this individually defined functional brain source. Source-based EEG neurofeedback methods using BSS may offer important advantages over traditional neurofeedback, by targeting the desired physiological signal in a more functionally and spatially specific manner. Having provided preliminary evidence of the feasibility of these methods, future work may study a range of clinically and experimentally relevant brain processes where individual brain sources may be targeted by source-based EEG neurofeedback. PMID

  12. Preliminary investigation of a technique to separate fission noble metals from fission-product mixtures

    Mellinger, G.B.; Jensen, G.A.

    1982-08-01

    A variation of the gold-ore fire assay technique was examined as a method for recovering Pd, Rh and Ru from fission products. The mixture of fission product oxides is combined with glass-forming chemicals, a metal oxide such as PbO (scavenging agent), and a reducing agent such as charcoal. When this mixture is melted, a metal button is formed which extracts the noble metals. The remainder cools to form a glass for nuclear waste storage. Recovery depended only on reduction of the scavenger oxide to metal. When such reduction was achieved, no difference in noble metal recovery efficiency was found among the scavengers studied (PbO, SnO, CuO, Bi 2 O 3 , Sb 2 O 3 ). Not all reducing agents studied, however, were able to reduce all scavenger oxides to metal. Only graphite would reduce SnO and CuO and allow noble metal recovery. The scavenger oxides Sb 2 O 3 , Bi 2 O 3 , and PbO, however, were reduced by all of the reducing agents tested. Similar noble metal recovery was found with each. Lead oxide was found to be the most promising of the potential scavengers. It was reduced by all of the reducing agents tested, and its higher density may facilitate the separation. Use of lead oxide also appeared to have no deterimental effect on the glass quality. Charcoal was identified as the preferred reducing agent. As long as a separable metal phase was formed in the melt, noble metal recovery was not dependent on the amount of reducing agent and scavenger oxide. High glass viscosities inhibited separation of the molten scavenger, while low viscosities allowed volatile loss of RuO 4 . A viscosity of approx. 20 poise at the processing temperature offered a good compromise between scavenger separation and Ru recovery. Glasses in which PbO was used as the scavenging agent were homogeneous in appearance. Resistance to leaching was close to that of certain waste glasses reported in the literature. 12 figures. 7 tables

  13. Surface-ionization ion source designed for in-beam operation with the BEMS-2 isotope separator

    Bogdanov, D.D.; Voboril, J.; Demyanov, A.V.; Karnaukhov, V.A.; Petrov, L.A.

    1976-01-01

    A surface-ionization ion source designed to operate in combination with the BEMS-2 isotope separator in a heavy ion beam is described. The ion source is adjusted for the separation of rare-earth elements. The separation efficiency for 150 Dy is determined to be equal to about 20% at the ionizer temperature of 2600 deg K. The hold-up times for praseodymium, promethium and dysprosium in the ion source range from 5 to 10 sec at the ionizer temperature of 2500-2700 deg K

  14. Separation and purification of uranium product from thorium in thorex process by precipitation technique

    Ramanujam, A.; Dhami, P.S.; Gopalakrishnan, V.; Mukherjee, A.; Dhumwad, R.K.

    1989-01-01

    A sequential precipitation technique is reported for the separation of uranium and thorium present in the uranium product stream of a single cycle 5 per cent TBP Thorex Process. It involves the precipitation of thorium as oxalate in 1M HNO 3 medium at 60-70degC and after filtration, precipitation of uranium as ammonium diuranate at 80-90degC from the oxalate supernatant. This technique has several advantages over the ion-exchange process normally used for treating these products. In order to meet the varying feed conditions, this method has been tested for feeds containing 10 g/1 uranium and 1-50 g/1 thorium in 1-6M HNO 3 . Various parameters like feed acidities, uranium and thorium concentrations, excess oxalic acid concentrations in the oxalate supernatant, precipitation temperatures, precipitate wash volumes etc. have been optimised to obtain more than 99 per cent recovery of thorium and uranium as their oxides with less than 50 ppm uranium losses to ammonium diuranate filtrate. The distribution patterns of different fission products and stainless steel corrosion products during various steps of this procedure have also been studied. For simulating the actual Thorex plant scale operation, experiments have been conducted with 25g and 100g lots of uranium per batch. (author). 6 tabs., 8 figs., 22 refs

  15. Effects of Sleep on Word Pair Memory in Children – Separating Item and Source Memory Aspects

    Jing-Yi Wang

    2017-09-01

    Full Text Available Word paired-associate learning is a well-established task to demonstrate sleep-dependent memory consolidation in adults as well as children. Sleep has also been proposed to benefit episodic features of memory, i.e., a memory for an event (item bound into the spatiotemporal context it has been experienced in (source. We aimed to explore if sleep enhances word pair memory in children by strengthening the episodic features of the memory, in particular. Sixty-one children (8–12 years studied two lists of word pairs with 1 h in between. Retrieval testing comprised cued recall of the target word of each word pair (item memory and recalling in which list the word pair had appeared in (source memory. Retrieval was tested either after 1 h (short retention interval or after 11 h, with this long retention interval covering either nocturnal sleep or daytime wakefulness. Compared with the wake interval, sleep enhanced separate recall of both word pairs and the lists per se, while recall of the combination of the word pair and the list it had appeared in remained unaffected by sleep. An additional comparison with adult controls (n = 37 suggested that item-source bound memory (combined recall of word pair and list is generally diminished in children. Our results argue against the view that the sleep-induced enhancement in paired-associate learning in children is a consequence of sleep specifically enhancing the episodic features of the memory representation. On the contrary, sleep in children might strengthen item and source representations in isolation, while leaving the episodic memory representations (item-source binding unaffected.

  16. Localization and separation of acoustic sources by using a 2.5-dimensional circular microphone array.

    Bai, Mingsian R; Lai, Chang-Sheng; Wu, Po-Chen

    2017-07-01

    Circular microphone arrays (CMAs) are sufficient in many immersive audio applications because azimuthal angles of sources are considered more important than the elevation angles in those occasions. However, the fact that CMAs do not resolve the elevation angle well can be a limitation for some applications which involves three-dimensional sound images. This paper proposes a 2.5-dimensional (2.5-D) CMA comprised of a CMA and a vertical logarithmic-spacing linear array (LLA) on the top. In the localization stage, two delay-and-sum beamformers are applied to the CMA and the LLA, respectively. The direction of arrival (DOA) is estimated from the product of two array output signals. In the separation stage, Tikhonov regularization and convex optimization are employed to extract the source amplitudes on the basis of the estimated DOA. The extracted signals from two arrays are further processed by the normalized least-mean-square algorithm with the internal iteration to yield the source signal with improved quality. To validate the 2.5-D CMA experimentally, a three-dimensionally printed circular array comprised of a 24-element CMA and an eight-element LLA is constructed. Objective perceptual evaluation of speech quality test and a subjective listening test are also undertaken.

  17. Application of PSA techniques to synchrotron radiation source facilities

    Sanyasi Rao, V.V.S.; Vinod, G.; Vaze, K.K.; Sarkar, P.K.

    2011-01-01

    Synchrotron radiation sources are increasingly being used in research and medical applications. Various instances of overexposure in these facilities have been reported in literature. These instances have lead to the investigation of the risks associated with them with a view to minimise the risks and thereby increasing the level of safety. In nuclear industry, Probabilistic Safety Assessment (PSA) methods are widely used to assess the risk from nuclear power plants. PSA presents a systematic methodology to evaluate the likelihood of various accident scenarios and their possible consequences using fault/event tree techniques. It is proposed to extend similar approach to analyse the risk associated with synchrotron radiation sources. First step for such an analysis is establishing the failure criteria, considering the regulatory stipulations on acceptable limits of dose due to ionization radiation from normal as well as beam loss scenarios. Some possible scenarios considered in this study are (1) excessive Bremsstrahlung in the ring due to loss of vacuum, (2) Target failure due to excessively focused beam (3) mis-directed/mis-steered beam (4) beam loss and sky shine. Hazard analysis needs to cover the beam transfer line, storage ring and experimental beam line areas. Various safety provisions are in place to minimize the hazards from these facilities such as access control interlock systems, radiation shielding for storage ring and beam lines and safety shutters (for beam lines). Experimental beam line area is the most vulnerable locations that need to be critically analysed. There are multiple beam lines, that have different safety provisions and consequences from postulated beam strikes will also be different and this increases the complexity of analysis. Similar studies conducted for such experimental facilities have identified that the radiation safety interlock system, used to control access to areas inside ring and the hutches of beamline facilities has an

  18. Blind source separation analysis of PET dynamic data: a simple method with exciting MR-PET applications

    Oros-Peusquens, Ana-Maria; Silva, Nuno da [Institute of Neuroscience and Medicine, Forschungszentrum Jülich GmbH, 52425 Jülich (Germany); Weiss, Carolin [Department of Neurosurgery, University Hospital Cologne, 50924 Cologne (Germany); Stoffels, Gabrielle; Herzog, Hans; Langen, Karl J [Institute of Neuroscience and Medicine, Forschungszentrum Jülich GmbH, 52425 Jülich (Germany); Shah, N Jon [Institute of Neuroscience and Medicine, Forschungszentrum Jülich GmbH, 52425 Jülich (Germany); Jülich-Aachen Research Alliance (JARA) - Section JARA-Brain RWTH Aachen University, 52074 Aachen (Germany)

    2014-07-29

    Denoising of dynamic PET data improves parameter imaging by PET and is gaining momentum. This contribution describes an analysis of dynamic PET data by blind source separation methods and comparison of the results with MR-based brain properties.

  19. Design of Smart Ion-Selective Electrode Arrays Based on Source Separation through Nonlinear Independent Component Analysis

    Duarte L.T.

    2014-03-01

    Full Text Available The development of chemical sensor arrays based on Blind Source Separation (BSS provides a promising solution to overcome the interference problem associated with Ion-Selective Electrodes (ISE. The main motivation behind this new approach is to ease the time-demanding calibration stage. While the first works on this problem only considered the case in which the ions under analysis have equal valences, the present work aims at developing a BSS technique that works when the ions have different charges. In this situation, the resulting mixing model belongs to a particular class of nonlinear systems that have never been studied in the BSS literature. In order to tackle this sort of mixing process, we adopted a recurrent network as separating system. Moreover, concerning the BSS learning strategy, we develop a mutual information minimization approach based on the notion of the differential of the mutual information. The method works requires a batch operation, and, thus, can be used to perform off-line analysis. The validity of our approach is supported by experiments where the mixing model parameters were extracted from actual data.

  20. A system dynamics model to evaluate effects of source separation of municipal solid waste management: A case of Bangkok, Thailand.

    Sukholthaman, Pitchayanin; Sharp, Alice

    2016-06-01

    Municipal solid waste has been considered as one of the most immediate and serious problems confronting urban government in most developing and transitional economies. Providing solid waste performance highly depends on the effectiveness of waste collection and transportation process. Generally, this process involves a large amount of expenditures and has very complex and dynamic operational problems. Source separation has a major impact on effectiveness of waste management system as it causes significant changes in quantity and quality of waste reaching final disposal. To evaluate the impact of effective source separation on waste collection and transportation, this study adopts a decision support tool to comprehend cause-and-effect interactions of different variables in waste management system. A system dynamics model that envisages the relationships of source separation and effectiveness of waste management in Bangkok, Thailand is presented. Influential factors that affect waste separation attitudes are addressed; and the result of change in perception on waste separation is explained. The impacts of different separation rates on effectiveness of provided collection service are compared in six scenarios. 'Scenario 5' gives the most promising opportunities as 40% of residents are willing to conduct organic and recyclable waste separation. The results show that better service of waste collection and transportation, less monthly expense, extended landfill life, and satisfactory efficiency of the provided service at 60.48% will be achieved at the end of the simulation period. Implications of how to get public involved and conducted source separation are proposed. Copyright © 2016 Elsevier Ltd. All rights reserved.

  1. Online artifact removal for brain-computer interfaces using support vector machines and blind source separation.

    Halder, Sebastian; Bensch, Michael; Mellinger, Jürgen; Bogdan, Martin; Kübler, Andrea; Birbaumer, Niels; Rosenstiel, Wolfgang

    2007-01-01

    We propose a combination of blind source separation (BSS) and independent component analysis (ICA) (signal decomposition into artifacts and nonartifacts) with support vector machines (SVMs) (automatic classification) that are designed for online usage. In order to select a suitable BSS/ICA method, three ICA algorithms (JADE, Infomax, and FastICA) and one BSS algorithm (AMUSE) are evaluated to determine their ability to isolate electromyographic (EMG) and electrooculographic (EOG) artifacts into individual components. An implementation of the selected BSS/ICA method with SVMs trained to classify EMG and EOG artifacts, which enables the usage of the method as a filter in measurements with online feedback, is described. This filter is evaluated on three BCI datasets as a proof-of-concept of the method.

  2. A review of output-only structural mode identification literature employing blind source separation methods

    Sadhu, A.; Narasimhan, S.; Antoni, J.

    2017-09-01

    Output-only modal identification has seen significant activity in recent years, especially in large-scale structures where controlled input force generation is often difficult to achieve. This has led to the development of new system identification methods which do not require controlled input. They often work satisfactorily if they satisfy some general assumptions - not overly restrictive - regarding the stochasticity of the input. Hundreds of papers covering a wide range of applications appear every year related to the extraction of modal properties from output measurement data in more than two dozen mechanical, aerospace and civil engineering journals. In little more than a decade, concepts of blind source separation (BSS) from the field of acoustic signal processing have been adopted by several researchers and shown that they can be attractive tools to undertake output-only modal identification. Originally intended to separate distinct audio sources from a mixture of recordings, mathematical equivalence to problems in linear structural dynamics have since been firmly established. This has enabled many of the developments in the field of BSS to be modified and applied to output-only modal identification problems. This paper reviews over hundred articles related to the application of BSS and their variants to output-only modal identification. The main contribution of the paper is to present a literature review of the papers which have appeared on the subject. While a brief treatment of the basic ideas are presented where relevant, a comprehensive and critical explanation of their contents is not attempted. Specific issues related to output-only modal identification and the relative advantages and limitations of BSS methods both from theoretical and application standpoints are discussed. Gap areas requiring additional work are also summarized and the paper concludes with possible future trends in this area.

  3. Saline sewage treatment and source separation of urine for more sustainable urban water management.

    Ekama, G A; Wilsenach, J A; Chen, G H

    2011-01-01

    While energy consumption and its associated carbon emission should be minimized in wastewater treatment, it has a much lower priority than human and environmental health, which are both closely related to efficient water quality management. So conservation of surface water quality and quantity are more important for sustainable development than green house gas (GHG) emissions per se. In this paper, two urban water management strategies to conserve fresh water quality and quantity are considered: (1) source separation of urine for improved water quality and (2) saline (e.g. sea) water toilet flushing for reduced fresh water consumption in coastal and mining cities. The former holds promise for simpler and shorter sludge age activated sludge wastewater treatment plants (no nitrification and denitrification), nutrient (Mg, K, P) recovery and improved effluent quality (reduced endocrine disruptor and environmental oestrogen concentrations) and the latter for significantly reduced fresh water consumption, sludge production and oxygen demand (through using anaerobic bioprocesses) and hence energy consumption. Combining source separation of urine and saline water toilet flushing can reduce sewer crown corrosion and reduce effluent P concentrations. To realize the advantages of these two approaches will require significant urban water management changes in that both need dual (fresh and saline) water distribution and (yellow and grey/brown) wastewater collection systems. While considerable work is still required to evaluate these new approaches and quantify their advantages and disadvantages, it would appear that the investment for dual water distribution and wastewater collection systems may be worth making to unlock their benefits for more sustainable urban development.

  4. Life cycle assessment and costing of urine source separation: Focus on nonsteroidal anti-inflammatory drug removal.

    Landry, Kelly A; Boyer, Treavor H

    2016-11-15

    Urine source separation has the potential to reduce pharmaceutical loading to the environment, while enhancing nutrient recovery. The focus of this life cycle assessment (LCA) was to evaluate the environmental impacts and economic costs to manage nonsteroidal anti-inflammatory drugs (NSAIDs) (i.e., diclofenac, ibuprofen, ketoprofen and naproxen) and nutrients in human urine. Urine source separation was compared with centralized wastewater treatment (WWT) (biological or upgraded with ozonation). The current treatment method (i.e., centralized biological WWT) was compared with hypothetical treatment scenarios (i.e., centralized biological WWT upgraded with ozonation, and urine source separation). Alternative urine source separation scenarios included varying collection and handling methods (i.e., collection by vacuum truck, vacuum sewer, or decentralized treatment), pharmaceuticals removal by ion-exchange, and struvite precipitation. Urine source separation scenarios had 90% lower environmental impact (based on the TRACI impact assessment method) compared with the centralized wastewater scenarios due to reduced potable water production for flush water, reduced electricity use at the wastewater treatment plant, and nutrient offsets from struvite precipitation. Despite the greatest reduction of pharmaceutical toxicity, centralized treatment upgraded with ozone had the greatest ecotoxicity impacts due to ozonation operation and infrastructure. Among urine source separation scenarios, decentralized treatment of urine and centralized treatment of urine collected by vacuum truck had negligible cost differences compared with centralized wastewater treatment. Centralized treatment of urine collected by vacuum sewer and centralized treatment with ozone cost 30% more compared with conventional wastewater treatment. Copyright © 2016 Elsevier Ltd. All rights reserved.

  5. Laser vaporization/ionization interface for coupling microscale separation techniques with mass spectrometry

    Yeung, E.S.; Chang, Y.C.

    1999-06-29

    The present invention provides a laser-induced vaporization and ionization interface for directly coupling microscale separation processes to a mass spectrometer. Vaporization and ionization of the separated analytes are facilitated by the addition of a light-absorbing component to the separation buffer or solvent. 8 figs.

  6. Techniques for long term conditioning and storage of radium sources

    Dogaru, Gheorghe; Dragolici, Felicia; Nicu, Mihaela

    2008-01-01

    The Horia Hulubei National Institute of Research and Development for Physics and Nuclear Engineering developed its own technology for conditioning the radium spent sealed radioactive sources. The laboratory dedicated to radiological characterization, identification of radium sources as well as the encapsulation of spent sealed radioactive sources was equipped with a local ventilation system, welding devices, tightness test devices as well as radiometric portable devices. Two types of capsules have been designed for conditioning of radium spent sealed radioactive sources. For these kinds of capsules different types of storage packaging were developed. Data on the radium inventory will be presented in the paper. The paper contains the description of the process of conditioning of spent sealed radioactive sources as well as the description of the capsules and packaging. The paper describes the equipment used for the conditioning of the radium spent sealed sources. (authors)

  7. Separation of trivalent actinide from lanthanide by a solvent extraction technique using imidazoledithiocarboxylic acid

    Miyashita, S.; Yanaga, M.; Okuno, K.; Suganuma, H.; Satoh, I.

    2006-01-01

    The extraction behavior of 241 Am and 152,154 Eu by a solvent extraction technique using imidazoledithiocarboxylic acid (IMD) were investigated. Although the solubility of IMD into organic solvent is very poor, it was improved by the formation of ion pair with hydrophobic cation, such as tetrabutylammonium ion (TBA + ) or tetraoctylammonium ion (TOA + ). The obtained tetrabutylammonium imidazole-dithiocarboxylate (TBA + IMD - ) and tetraoctylammonium imidazoledithiocarboxylate (TOA + TMD - ) are able to solve into various organic solvents, for example cyclohexanone, chloroform and nitrobenzene, but not to solve into nonpolar alkane. The radionuclides of Am(III) and Eu(III) are able to be extracted in the region of 2 eq + IMD - /cyclohexanone and TOA + IMD - /cyclohexanone. The distribution ratio of Am(III) is higher than that of Eu(III) when the organic phase is 0.1 M TBA + IMD - /cyclohexanone and the aqueous phase is 1.0 M (H,Na)NO 3 . The separation factor (Am(III)/Eu(III)) at pH eq =5.5 is ca. 30. In the region of pH>6, the distribution ratios of Am(III) and Eu(III) in the system described above showed constant values, respectively. (author)

  8. Studies on the remediation of environment contaminated with radioactive pollutants using the chemical separation technique

    Kurotaki, Katsumi; Yonehara, Hidenori; Sahoo, S.K. [National Inst. of Radiological Sciences, Chiba (Japan); Ishii, Toshiaki [National Inst. of Radiological Sciences, Hitachinaka, Ibaraki (Japan). Lab. for Radioecology

    2001-12-01

    Remediation of soil and drinking water contaminated with radioactive nuclides is important for the mitigation of radiation exposure. Then we attempted to construct the remediation system including the dose estimation system using the chemical separation technique to remove pollutants from the environment. The information on air dose rate is important for assessment of risk from the radiation exposure. Then we measured the air dose rate and analysed the relationship between air dose rate and the contamination of soil at the area in Russia (Bryansk district) contaminated by Chernobyl Nuclear Power Plant accident. Moreover, we analysed the soil of Bryansk district on the concentration of rare earth elements, thorium and uranium and on the isotope ratio of strontium. On the other hand, we tried to develop the rapid measurement method of radioactivity of Sr-90 which is one of the dangerous radionuclides, because the method of radioactivity measurement in the literature is too time-consuming. It was reported recently that the molecules containing SH group form the covalent bond with gold atoms at the surface of gold plate and that crown ether compounds have strong affinity to strontium. Then we attempted to synthesize the crown ether containing SH group. In addition, we search the inorganic elements accumulated to special organisms of fishes and other animals in sea in order to find out new reagent for trace elements. Transition metal such as Co, Fe, Ni, Ti, V and Zn were detected from the intracellular granules in the bronchial heart of octopus. (author)

  9. Antimicrobial peptide from mucus of Andrias davidianus: screening and purification by magnetic cell membrane separation technique.

    Pei, Jinjin; Jiang, Lei

    2017-07-01

    Andrias davidianus, the Chinese giant salamander, has been used in traditional Chinese medicine for many decades. However, no antimicrobial peptides (AMPs) have been described from A. davidianus until now. Here we describe a novel AMP (andricin 01) isolated from the mucus of A. davidianus. The peptide was recovered using an innovative magnetic cell membrane separation technique and was characterised using mass spectrometry and circular dichroism (CD) spectroscopy. Andricin 01 is comprised of ten amino acid residues with a total molecular mass of 955.1 Da. CD spectrum analysis gave results similar to the archetypal random coil spectrum, consistent with the three-dimensional rendering calculated by current bioinformatics tools. Andricin 01 was found to be inhibitory both to Gram-negative and Gram-positive bacteria. Furthermore, the peptide at the minimal bacterial concentration did not show cell cytotoxicity against human hepatocytes or renal cells and did not show haemolytic activity against red blood cells, indicating that is potentially safe and effective for human use. Andricin 01 shows promise as a novel antibacterial that may provide an insight into the development of new drugs. Copyright © 2017 Elsevier B.V. and International Society of Chemotherapy. All rights reserved.

  10. Effect of temperature on acid-base equilibria in separation techniques. A review.

    Gagliardi, Leonardo G; Tascon, Marcos; Castells, Cecilia B

    2015-08-19

    Studies on the theoretical principles of acid-base equilibria are reviewed and the influence of temperature on secondary chemical equilibria within the context of separation techniques, in water and also in aqueous-organic solvent mixtures, is discussed. In order to define the relationships between the retention in liquid chromatography or the migration velocity in capillary electrophoresis and temperature, the main properties of acid-base equilibria have to be taken into account for both, the analytes and the conjugate pairs chosen to control the solution pH. The focus of this review is based on liquid-liquid extraction (LLE), liquid chromatography (LC) and capillary electrophoresis (CE), with emphasis on the use of temperature as a useful variable to modify selectivity on a predictable basis. Simplified models were evaluated to achieve practical optimizations involving pH and temperature (in LLE and CE) as well as solvent composition in reversed-phase LC. Copyright © 2015 Elsevier B.V. All rights reserved.

  11. Privacy-Preserving Data Mining of Medical Data Using Data Separation-Based Techniques

    Gang Kou

    2007-08-01

    Full Text Available Data mining is concerned with the extraction of useful knowledge from various types of data. Medical data mining has been a popular data mining topic of late. Compared with other data mining areas, medical data mining has some unique characteristics. Because medical files are related to human subjects, privacy concerns are taken more seriously than other data mining tasks. This paper applied data separation-based techniques to preserve privacy in classification of medical data. We take two approaches to protect privacy: one approach is to vertically partition the medical data and mine these partitioned data at multiple sites; the other approach is to horizontally split data across multiple sites. In the vertical partition approach, each site uses a portion of the attributes to compute its results, and the distributed results are assembled at a central trusted party using a majority-vote ensemble method. In the horizontal partition approach, data are distributed among several sites. Each site computes its own data, and a central trusted party is responsible to integrate these results. We implement these two approaches using medical datasets from UCI KDD archive and report the experimental results.

  12. A scintillation camera technique for quantitative estimation of separate kidney function and its use before nephrectomy

    Larsson, I.; Lindstedt, E.; Ohlin, P.; Strand, S.E.; White, T.

    1975-01-01

    A scintillation camera technique was used for measuring renal uptake of [ 131 I]Hippuran 80-110 s after injection. Externally measured Hippuran uptake was markedly influenced by kidney depth, which was measured by lateral-view image after injection of [ 99 Tc]iron ascorbic acid complex or [ 197 Hg]chlormerodrine. When one kidney was nearer to the dorsal surface of the body than the other, it was necessary to correct the externally measured Hippuran uptake for kidney depth to obtain reliable information on the true partition of Hippuran between the two kidneys. In some patients the glomerular filtration rate (GFR) was measured before and after nephrectomy. Measured postoperative GFR was compared with preoperative predicted GFR, which was calculated by multiplying the preoperative Hippuran uptake of the kidney to be left in situ, as a fraction of the preoperative Hippuran uptake of both kidneys, by the measured preoperative GFR. The measured postoperative GFR was usually moderately higher than the preoperatively predicted GFR. The difference could be explained by a postoperative compensatory increase in function of the remaining kidney. Thus, the present method offers a possibility of estimating separate kidney function without arterial or ureteric catheterization. (auth)

  13. An application of the theory of planned behaviour to study the influencing factors of participation in source separation of food waste.

    Karim Ghani, Wan Azlina Wan Ab; Rusli, Iffah Farizan; Biak, Dayang Radiah Awang; Idris, Azni

    2013-05-01

    Tremendous increases in biodegradable (food waste) generation significantly impact the local authorities, who are responsible to manage, treat and dispose of this waste. The process of separation of food waste at its generation source is identified as effective means in reducing the amount food waste sent to landfill and can be reused as feedstock to downstream treatment processes namely composting or anaerobic digestion. However, these efforts will only succeed with positive attitudes and highly participations rate by the public towards the scheme. Thus, the social survey (using questionnaires) to analyse public's view and influencing factors towards participation in source separation of food waste in households based on the theory of planned behaviour technique (TPB) was performed in June and July 2011 among selected staff in Universiti Putra Malaysia, Serdang, Selangor. The survey demonstrates that the public has positive intention in participating provided the opportunities, facilities and knowledge on waste separation at source are adequately prepared by the respective local authorities. Furthermore, good moral values and situational factors such as storage convenience and collection times are also encouraged public's involvement and consequently, the participations rate. The findings from this study may provide useful indicator to the waste management authorities in Malaysia in identifying mechanisms for future development and implementation of food waste source separation activities in household programmes and communication campaign which advocate the use of these programmes. Copyright © 2012 Elsevier Ltd. All rights reserved.

  14. Treatment of Source-Separated Blackwater: A Decentralized Strategy for Nutrient Recovery towards a Circular Economy

    Melesse Eshetu Moges

    2018-04-01

    Full Text Available Using a filter medium for organic matter removal and nutrient recovery from blackwater treatment is a novel concept and has not been investigated sufficiently to date. This paper demonstrates a combined blackwater treatment and nutrient-recovery strategy and establishes mechanisms for a more dependable source of plant nutrients aiming at a circular economy. Source-separated blackwater from a student dormitory was used as feedstock for a sludge blanket anaerobic-baffled reactor. The effluent from the reactor, with 710 mg L−1 NH4–N and 63 mg L−1 PO4–P, was treated in a sequence of upflow and downflow filtration columns using granular activated carbon, Cocos char and polonite as filter media at a flow rate of 600 L m−2 day−1 and organic loading rate of 430 g chemical oxygen demand (COD m−2 day−1. Filtration treatment of the anaerobic effluent with carbon adsorbents removed 80% of the residual organic matter, more than 90% of suspended solids, and turbidity while releasing more than 76% NH4–N and 85% of PO4–P in the liquid phase. The treatment train also removed total coliform bacteria and E. coli in the effluent, achieving concentrations below detection limit after the integration of ultraviolet (UV light. These integrated technological pathways ensure simultaneous nutrient recovery as a nutrient solution, pathogen inactivation, and reduction of active organic substances. The treated nutrient-rich water can be applied as a source of value creation for various end-use options.

  15. Non classical sources of uranium and their extraction techniques

    Ziegler, V [CEA, 75 - Paris (France)

    1978-11-01

    Non classical uranium sources are reviewed: phosphates, sea water, porphyric copper tailings, minerals allowing in-situ lixiviation, black carbon shales, coals and lignites, granitic rocks. An economical study has shown which sources could be really operative (phosphates seem the most attractive). The situation of uranium supplies does not seem to be actually modified by exploitation of these resources.

  16. The Crowding-Out Effects of Garbage Fees and Voluntary Source Separation Programs on Waste Reduction: Evidence from China

    Hongyun Han

    2016-07-01

    Full Text Available This paper examines how and to what degree government policies of garbage fees and voluntary source separation programs, with free indoor containers and garbage bags, can affect the effectiveness of municipal solid waste (MSW management, in the sense of achieving a desirable reduction of per capita MSW generation. Based on city-level panel data for years 1998–2012 in China, our empirical analysis indicates that per capita MSW generated is increasing with per capita disposable income, average household size, education levels of households, and the lagged per capita MSW. While both garbage fees and source separation programs have separately led to reductions in per capita waste generation, the interaction of the two policies has resulted in an increase in per capita waste generation due to the following crowding-out effects: Firstly, the positive effect of income dominates the negative effect of the garbage fee. Secondly, there are crowding-out effects of mandatory charging system and the subsidized voluntary source separation on per capita MSW generation. Thirdly, small subsidies and tax punishments have reduced the intrinsic motivation for voluntary source separation of MSW. Thus, compatible fee charging system, higher levels of subsidies, and well-designed public information and education campaigns are required to promote household waste source separation and reduction.

  17. A simple and sensitive separation technique of 99Mo and 99mTc from their equilibrium mixture

    Swadesh Mandal; Ajoy Mandal

    2014-01-01

    The present work describes a simple and inexpensive separation method of 99 Mo from the equilibrium mixture. The liquid-liquid extraction technique has been employed to separate 99 Mo and 99m Tc using triisooctylamine (TIOA). The 99 Mo and 99m Tc were quantitatively separated out in 2 M TIOA with tripled distilled water; 99m Tc was back extracted from TIOA organic phase to aqueous phase by 0.1 M DTPA. The species information or indirect speciation of molybdenum was also established by the extraction profile of the molybdenum. (author)

  18. Ambiguity of source location in acoustic emission technique

    Barat, P.; Mukherjee, P.; Kalyanasundaram, P.; Raj, B.

    1996-01-01

    Location of acoustic emission (AE) source in a plane is detected from the difference of the arrival times of the AE signal to at least three sensors placed on it. The detected location may not be unique in all cases. In this paper, the condition for the unambiguous solution for the location of the source has been deduced mathematically in terms of arrival times of the AE signal, the coordinate of the three sensors and the acoustic velocity. (author)

  19. Optimization conditions for the separation of rare earth elements, americium, curium and cesium with HPLC technique

    Goutelard, F.; Caussignac, C.; Brennetot, R.; Stadelmann, G.; Gautier, C.

    2009-01-01

    In order to validate the neutronic code calculations used in the nuclear field, it is necessary to quantify the isotopic composition of the nuclear irradiated fuels with high precision and accuracy. A separation step whose objective is to isolate the elements of interest in a fraction as pure as possible, is performed before mass spectrometry detection (MC-ICP-MS, TIMS), in order to eliminate isobaric interferences. In a first step, uranium and plutonium are separated from the fission products by ion exchange chromatography. Then, fission products are separated by high performance liquid chromatography (HPLC). A gradient separation with a silica sulphonated support as stationary phase and hydroxy-methyl butyric acid (HMB) as eluent solution provides a good degree of separation of the rare earth elements, Am, Cm and Cs. But, for a same manufacturer, the rate of sulphonated groups is variable from one column to another for a given production batch. For every replacement of column, it is necessary to adjust the separation conditions. Furthermore, the high radioactivity of the samples injected damages the stationary phase, dragging a regular renewal of the columns. The goal of this study is to determine the optimal separation conditions with a minimum of tests in order to limit the time assigned to this operation. A first Doehlert experimental design with pH and HMB concentration as variables has been implemented to optimize Gd, Eu separation, in isocratic initial conditions. A second one has been tested in order to separate the higher lanthanides and to fix the final conditions of the gradient separation. A last set of tests has been performed to characterize the cesium behaviour. Finally, the gradient conditions have been adjusted in order to perform the full separation of lanthanides, Cs, Am and Cm with nuclear facilities. (author)

  20. An application of the theory of planned behaviour to study the influencing factors of participation in source separation of food waste

    Karim Ghani, Wan Azlina Wan Ab.; Rusli, Iffah Farizan; Biak, Dayang Radiah Awang; Idris, Azni

    2013-01-01

    Highlights: ► Theory of planned behaviour (TPB) has been conducted to identify the influencing factors for participation in source separation of food waste using self administered questionnaires. ► The findings suggested several implications for the development and implementation of waste separation at home programme. ► The analysis indicates that the attitude towards waste separation is determined as the main predictors where this in turn could be a significant predictor of the repondent’s actual food waste separation behaviour. ► To date, none of similar have been reported elsewhere and this finding will be beneficial to local Authorities as indicator in designing campaigns to promote the use of waste separation programmes to reinforce the positive attitudes. - Abstract: Tremendous increases in biodegradable (food waste) generation significantly impact the local authorities, who are responsible to manage, treat and dispose of this waste. The process of separation of food waste at its generation source is identified as effective means in reducing the amount food waste sent to landfill and can be reused as feedstock to downstream treatment processes namely composting or anaerobic digestion. However, these efforts will only succeed with positive attitudes and highly participations rate by the public towards the scheme. Thus, the social survey (using questionnaires) to analyse public’s view and influencing factors towards participation in source separation of food waste in households based on the theory of planned behaviour technique (TPB) was performed in June and July 2011 among selected staff in Universiti Putra Malaysia, Serdang, Selangor. The survey demonstrates that the public has positive intention in participating provided the opportunities, facilities and knowledge on waste separation at source are adequately prepared by the respective local authorities. Furthermore, good moral values and situational factors such as storage convenience and

  1. An application of the theory of planned behaviour to study the influencing factors of participation in source separation of food waste

    Karim Ghani, Wan Azlina Wan Ab., E-mail: wanaz@eng.upm.edu.my [Department of Chemical and Environmental Engineering, Faculty of Engineering, University Putra Malaysia, 43400 Serdang, Selangor Darul Ehsan (Malaysia); Rusli, Iffah Farizan, E-mail: iffahrusli@yahoo.com [Department of Chemical and Environmental Engineering, Faculty of Engineering, University Putra Malaysia, 43400 Serdang, Selangor Darul Ehsan (Malaysia); Biak, Dayang Radiah Awang, E-mail: dayang@eng.upm.edu.my [Department of Chemical and Environmental Engineering, Faculty of Engineering, University Putra Malaysia, 43400 Serdang, Selangor Darul Ehsan (Malaysia); Idris, Azni, E-mail: azni@eng.upm.edu.my [Department of Chemical and Environmental Engineering, Faculty of Engineering, University Putra Malaysia, 43400 Serdang, Selangor Darul Ehsan (Malaysia)

    2013-05-15

    Highlights: ► Theory of planned behaviour (TPB) has been conducted to identify the influencing factors for participation in source separation of food waste using self administered questionnaires. ► The findings suggested several implications for the development and implementation of waste separation at home programme. ► The analysis indicates that the attitude towards waste separation is determined as the main predictors where this in turn could be a significant predictor of the repondent’s actual food waste separation behaviour. ► To date, none of similar have been reported elsewhere and this finding will be beneficial to local Authorities as indicator in designing campaigns to promote the use of waste separation programmes to reinforce the positive attitudes. - Abstract: Tremendous increases in biodegradable (food waste) generation significantly impact the local authorities, who are responsible to manage, treat and dispose of this waste. The process of separation of food waste at its generation source is identified as effective means in reducing the amount food waste sent to landfill and can be reused as feedstock to downstream treatment processes namely composting or anaerobic digestion. However, these efforts will only succeed with positive attitudes and highly participations rate by the public towards the scheme. Thus, the social survey (using questionnaires) to analyse public’s view and influencing factors towards participation in source separation of food waste in households based on the theory of planned behaviour technique (TPB) was performed in June and July 2011 among selected staff in Universiti Putra Malaysia, Serdang, Selangor. The survey demonstrates that the public has positive intention in participating provided the opportunities, facilities and knowledge on waste separation at source are adequately prepared by the respective local authorities. Furthermore, good moral values and situational factors such as storage convenience and

  2. Nonnegative Tensor Factorization Approach Applied to Fission Chamber’s Output Signals Blind Source Separation

    Laassiri, M.; Hamzaoui, E.-M.; Cherkaoui El Moursli, R.

    2018-02-01

    Inside nuclear reactors, gamma-rays emitted from nuclei together with the neutrons introduce unwanted backgrounds in neutron spectra. For this reason, powerful extraction methods are needed to extract useful neutron signal from recorded mixture and thus to obtain clearer neutron flux spectrum. Actually, several techniques have been developed to discriminate between neutrons and gamma-rays in a mixed radiation field. Most of these techniques, tackle using analogue discrimination methods. Others propose to use some organic scintillators to achieve the discrimination task. Recently, systems based on digital signal processors are commercially available to replace the analog systems. As alternative to these systems, we aim in this work to verify the feasibility of using a Nonnegative Tensor Factorization (NTF) to blind extract neutron component from mixture signals recorded at the output of fission chamber (WL-7657). This last have been simulated through the Geant4 linked to Garfield++ using a 252Cf neutron source. To achieve our objective of obtaining the best possible neutron-gamma discrimination, we have applied the two different NTF algorithms, which have been found to be the best methods that allow us to analyse this kind of nuclear data.

  3. Blind Source Separation Algorithms Using Hyperbolic and Givens Rotations for High-Order QAM Constellations

    Shah, Syed Awais Wahab

    2017-11-24

    This paper addresses the problem of blind demixing of instantaneous mixtures in a multiple-input multiple-output communication system. The main objective is to present efficient blind source separation (BSS) algorithms dedicated to moderate or high-order QAM constellations. Four new iterative batch BSS algorithms are presented dealing with the multimodulus (MM) and alphabet matched (AM) criteria. For the optimization of these cost functions, iterative methods of Givens and hyperbolic rotations are used. A pre-whitening operation is also utilized to reduce the complexity of design problem. It is noticed that the designed algorithms using Givens rotations gives satisfactory performance only for large number of samples. However, for small number of samples, the algorithms designed by combining both Givens and hyperbolic rotations compensate for the ill-whitening that occurs in this case and thus improves the performance. Two algorithms dealing with the MM criterion are presented for moderate order QAM signals such as 16-QAM. The other two dealing with the AM criterion are presented for high-order QAM signals. These methods are finally compared with the state of art batch BSS algorithms in terms of signal-to-interference and noise ratio, symbol error rate and convergence rate. Simulation results show that the proposed methods outperform the contemporary batch BSS algorithms.

  4. Feature Selection and Blind Source Separation in an EEG-Based Brain-Computer Interface

    Michael H. Thaut

    2005-11-01

    Full Text Available Most EEG-based BCI systems make use of well-studied patterns of brain activity. However, those systems involve tasks that indirectly map to simple binary commands such as “yes” or “no” or require many weeks of biofeedback training. We hypothesized that signal processing and machine learning methods can be used to discriminate EEG in a direct “yes”/“no” BCI from a single session. Blind source separation (BSS and spectral transformations of the EEG produced a 180-dimensional feature space. We used a modified genetic algorithm (GA wrapped around a support vector machine (SVM classifier to search the space of feature subsets. The GA-based search found feature subsets that outperform full feature sets and random feature subsets. Also, BSS transformations of the EEG outperformed the original time series, particularly in conjunction with a subset search of both spaces. The results suggest that BSS and feature selection can be used to improve the performance of even a “direct,” single-session BCI.

  5. Mixing Matrix Estimation of Underdetermined Blind Source Separation Based on Data Field and Improved FCM Clustering

    Qiang Guo

    2018-01-01

    Full Text Available In modern electronic warfare, multiple input multiple output (MIMO radar has become an important tool for electronic reconnaissance and intelligence transmission because of its anti-stealth, high resolution, low intercept and anti-destruction characteristics. As a common MIMO radar signal, discrete frequency coding waveform (DFCW has a serious overlap of both time and frequency, so it cannot be directly used in the current radar signal separation problems. The existing fuzzy clustering algorithms have problems in initial value selection, low convergence rate and local extreme values which will lead to the low accuracy of the mixing matrix estimation. Consequently, a novel mixing matrix estimation algorithm based on data field and improved fuzzy C-means (FCM clustering is proposed. First of all, the sparsity and linear clustering characteristics of the time–frequency domain MIMO radar signals are enhanced by using the single-source principal value of complex angular detection. Secondly, the data field uses the potential energy information to analyze the particle distribution, thus design a new clustering number selection scheme. Then the particle swarm optimization algorithm is introduced to improve the iterative clustering process of FCM, and finally get the estimated value of the mixing matrix. The simulation results show that the proposed algorithm improves both the estimation accuracy and the robustness of the mixing matrix.

  6. Fate of personal care and household products in source separated sanitation.

    Butkovskyi, A; Rijnaarts, H H M; Zeeman, G; Hernandez Leal, L

    2016-12-15

    Removal of twelve micropollutants, namely biocides, fragrances, ultraviolet (UV)-filters and preservatives in source separated grey and black water treatment systems was studied. All compounds were present in influent grey water in μg/l range. Seven compounds were found in influent black water. Their removal in an aerobic activated sludge system treating grey water ranged from 59% for avobenzone to >99% for hexylcinnamaldehyde. High concentrations of hydrophobic micropollutants in sludge of aerobic activated sludge system indicated the importance of sorption for their removal. Six micropollutants were found in sludge of an Up-flow anaerobic sludge blanket (UASB) reactor treating black water, with four of them being present at significantly higher concentrations after addition of grey water sludge to the reactor. Hence, addition of grey water sludge to the UASB reactor is likely to increase micropollutant content in UASB sludge. This approach should not be followed when excess UASB sludge is designed to be reused as soil amendment. Copyright © 2016 Elsevier B.V. All rights reserved.

  7. Insects associated with the composting process of solid urban waste separated at the source

    Gladis Estela Morales

    2010-01-01

    Full Text Available Sarcosaprophagous macroinvertebrates (earthworms, termites and a number of Diptera larvae enhance changes in the physical and chemical properties of organic matter during degradation and stabilization processes in composting, causing a decrease in the molecular weights of compounds. This activity makes these organisms excellent recyclers of organic matter. This article evaluates the succession of insects associated with the decomposition of solid urban waste separated at the source. The study was carried out in the city of Medellin, Colombia. A total of 11,732 individuals were determined, belonging to the classes Insecta and Arachnida. Species of three orders of Insecta were identified, Diptera, Coleoptera and Hymenoptera. Diptera corresponding to 98.5% of the total, was the most abundant and diverse group, with 16 families (Calliphoridae, Drosophilidae, Psychodidae, Fanniidae, Muscidae, Milichiidae, Ulidiidae, Scatopsidae, Sepsidae, Sphaeroceridae, Heleomyzidae, Stratiomyidae, Syrphidae, Phoridae, Tephritidae and Curtonotidae followed by Coleoptera with five families (Carabidae, Staphylinidae, Ptiliidae, Hydrophilidae and Phalacaridae. Three stages were observed during the composting process, allowing species associated with each stage to be identified. Other species were also present throughout the whole process. In terms of number of species, Diptera was the most important group observed, particularly Ornidia obesa, considered a highly invasive species, and Hermetia illuscens, both reported as beneficial for decomposition of organic matter.

  8. Blind Source Separation Algorithms Using Hyperbolic and Givens Rotations for High-Order QAM Constellations

    Shah, Syed Awais Wahab; Abed-Meraim, Karim; Al-Naffouri, Tareq Y.

    2017-01-01

    This paper addresses the problem of blind demixing of instantaneous mixtures in a multiple-input multiple-output communication system. The main objective is to present efficient blind source separation (BSS) algorithms dedicated to moderate or high-order QAM constellations. Four new iterative batch BSS algorithms are presented dealing with the multimodulus (MM) and alphabet matched (AM) criteria. For the optimization of these cost functions, iterative methods of Givens and hyperbolic rotations are used. A pre-whitening operation is also utilized to reduce the complexity of design problem. It is noticed that the designed algorithms using Givens rotations gives satisfactory performance only for large number of samples. However, for small number of samples, the algorithms designed by combining both Givens and hyperbolic rotations compensate for the ill-whitening that occurs in this case and thus improves the performance. Two algorithms dealing with the MM criterion are presented for moderate order QAM signals such as 16-QAM. The other two dealing with the AM criterion are presented for high-order QAM signals. These methods are finally compared with the state of art batch BSS algorithms in terms of signal-to-interference and noise ratio, symbol error rate and convergence rate. Simulation results show that the proposed methods outperform the contemporary batch BSS algorithms.

  9. Potential Ambient Energy-Harvesting Sources and Techniques

    Yildiz, Faruk

    2009-01-01

    Ambient energy harvesting is also known as energy scavenging or power harvesting, and it is the process where energy is obtained from the environment. A variety of techniques are available for energy scavenging, including solar and wind powers, ocean waves, piezoelectricity, thermoelectricity, and physical motions. For example, some systems…

  10. Recent progress in developments of membrane materials and modification techniques for high performance helium separation and recovery : a review

    Soleimany, A.; Hosseini, S.S.; Gallucci, F.

    2017-01-01

    Helium is a valuable gas with unique properties and applications and still the prominent industrial source of helium is natural gas. Because of several advantages of membrane-based separation processes over conventional methods as well as the lack of a comprehensive scientific report, the present

  11. Perturbed invariant subspaces and approximate generalized functional variable separation solution for nonlinear diffusion-convection equations with weak source

    Xia, Ya-Rong; Zhang, Shun-Li; Xin, Xiang-Peng

    2018-03-01

    In this paper, we propose the concept of the perturbed invariant subspaces (PISs), and study the approximate generalized functional variable separation solution for the nonlinear diffusion-convection equation with weak source by the approximate generalized conditional symmetries (AGCSs) related to the PISs. Complete classification of the perturbed equations which admit the approximate generalized functional separable solutions (AGFSSs) is obtained. As a consequence, some AGFSSs to the resulting equations are explicitly constructed by way of examples.

  12. A multilevel reuse system with source separation process for printing and dyeing wastewater treatment: A case study.

    Wang, Rui; Jin, Xin; Wang, Ziyuan; Gu, Wantao; Wei, Zhechao; Huang, Yuanjie; Qiu, Zhuang; Jin, Pengkang

    2018-01-01

    This paper proposes a new system of multilevel reuse with source separation in printing and dyeing wastewater (PDWW) treatment in order to dramatically improve the water reuse rate to 35%. By analysing the characteristics of the sources and concentrations of pollutants produced in different printing and dyeing processes, special, highly, and less contaminated wastewaters (SCW, HCW, and LCW, respectively) were collected and treated separately. Specially, a large quantity of LCW was sequentially reused at multiple levels to meet the water quality requirements for different production processes. Based on this concept, a multilevel reuse system with a source separation process was established in a typical printing and dyeing enterprise. The water reuse rate increased dramatically to 62%, and the reclaimed water was reused in different printing and dyeing processes based on the water quality. This study provides promising leads in water management for wastewater reclamation. Copyright © 2017 Elsevier Ltd. All rights reserved.

  13. Life cycle comparison of centralized wastewater treatment and urine source separation with struvite precipitation: Focus on urine nutrient management.

    Ishii, Stephanie K L; Boyer, Treavor H

    2015-08-01

    Alternative approaches to wastewater management including urine source separation have the potential to simultaneously improve multiple aspects of wastewater treatment, including reduced use of potable water for waste conveyance and improved contaminant removal, especially nutrients. In order to pursue such radical changes, system-level evaluations of urine source separation in community contexts are required. The focus of this life cycle assessment (LCA) is managing nutrients from urine produced in a residential setting with urine source separation and struvite precipitation, as compared with a centralized wastewater treatment approach. The life cycle impacts evaluated in this study pertain to construction of the urine source separation system and operation of drinking water treatment, decentralized urine treatment, and centralized wastewater treatment. System boundaries include fertilizer offsets resulting from the production of urine based struvite fertilizer. As calculated by the Tool for the Reduction and Assessment of Chemical and Other Environmental Impacts (TRACI), urine source separation with MgO addition for subsequent struvite precipitation with high P recovery (Scenario B) has the smallest environmental cost relative to existing centralized wastewater treatment (Scenario A) and urine source separation with MgO and Na3PO4 addition for subsequent struvite precipitation with concurrent high P and N recovery (Scenario C). Preliminary economic evaluations show that the three urine management scenarios are relatively equal on a monetary basis (<13% difference). The impacts of each urine management scenario are most sensitive to the assumed urine composition, the selected urine storage time, and the assumed electricity required to treat influent urine and toilet water used to convey urine at the centralized wastewater treatment plant. The importance of full nutrient recovery from urine in combination with the substantial chemical inputs required for N recovery

  14. The management challenge for household waste in emerging economies like Brazil: realistic source separation and activation of reverse logistics.

    Fehr, M

    2014-09-01

    Business opportunities in the household waste sector in emerging economies still evolve around the activities of bulk collection and tipping with an open material balance. This research, conducted in Brazil, pursued the objective of shifting opportunities from tipping to reverse logistics in order to close the balance. To do this, it illustrated how specific knowledge of sorted waste composition and reverse logistics operations can be used to determine realistic temporal and quantitative landfill diversion targets in an emerging economy context. Experimentation constructed and confirmed the recycling trilogy that consists of source separation, collection infrastructure and reverse logistics. The study on source separation demonstrated the vital difference between raw and sorted waste compositions. Raw waste contained 70% biodegradable and 30% inert matter. Source separation produced 47% biodegradable, 20% inert and 33% mixed material. The study on collection infrastructure developed the necessary receiving facilities. The study on reverse logistics identified private operators capable of collecting and processing all separated inert items. Recycling activities for biodegradable material were scarce and erratic. Only farmers would take the material as animal feed. No composting initiatives existed. The management challenge was identified as stimulating these activities in order to complete the trilogy and divert the 47% source-separated biodegradable discards from the landfills. © The Author(s) 2014.

  15. Improvement of a separation method for the reduction of secondary waste from the water-jet abrasive suspension cutting technique

    Brandauer, M.; Gentes, S.; Heneka, A.; Krauss, C.O.; Geckeis, H.; Plaschke, M.; Schild, D.; Tobie, W.

    2017-01-01

    Full text of publication follows. Disassembling the reactor pressure vessel and its built-in components is a huge challenge in the deconstruction of a nuclear power plant. After being exposed to neutron irradiation for years, the activated components need to be disassembled and packed by remote controlled techniques. Underwater disassembling systems have the advantage of the shielding effect of water against radiation. To avoid the generation of aerosols, cold cutting processes are preferred. A cutting method that meets these requirements is the water-jet abrasive suspension cutting technique (WASS). This method provides high flexibility and is immune towards mechanical stress in the components. During the cutting process, a mixture of abrasive particles and radioactive steel particles from the cut components is generated. Depending on the operational conditions, the amount of this secondary waste increases substantially. Therefore, despite of its intrinsic technical benefits, WASS has a serious disadvantage towards other cutting techniques due to the huge disposal costs of secondary waste. During our previous joint research project between KIT and AREVA GmbH called NENAWAS ('New Disposal Methods for the Secondary Waste Treatment of the Water-jet Abrasive Suspension Cutting Technique', funded by the German ministry for education and research, BMBF), a prototype separation device for WASS secondary waste was developed and tested. Using a magnetic filter, steel particles could be successfully separated from the rest of the secondary waste. The separation process is examined using elemental analysis (ICP-OES) for quantification of the separation grade. Additionally, morphologies of particles and particle aggregates before and after the separation process were examined by scanning electron microscopy (SEM). In the abrasive particle fraction after separation of the steel particles a remaining contamination by tiny steel particles could be detected by elemental and

  16. Estimation of nitrite in source-separated nitrified urine with UV spectrophotometry.

    Mašić, Alma; Santos, Ana T L; Etter, Bastian; Udert, Kai M; Villez, Kris

    2015-11-15

    Monitoring of nitrite is essential for an immediate response and prevention of irreversible failure of decentralized biological urine nitrification reactors. Although a few sensors are available for nitrite measurement, none of them are suitable for applications in which both nitrite and nitrate are present in very high concentrations. Such is the case in collected source-separated urine, stabilized by nitrification for long-term storage. Ultraviolet (UV) spectrophotometry in combination with chemometrics is a promising option for monitoring of nitrite. In this study, an immersible in situ UV sensor is investigated for the first time so to establish a relationship between UV absorbance spectra and nitrite concentrations in nitrified urine. The study focuses on the effects of suspended particles and saturation on the absorbance spectra and the chemometric model performance. Detailed analysis indicates that suspended particles in nitrified urine have a negligible effect on nitrite estimation, concluding that sample filtration is not necessary as pretreatment. In contrast, saturation due to very high concentrations affects the model performance severely, suggesting dilution as an essential sample preparation step. However, this can also be mitigated by simple removal of the saturated, lower end of the UV absorbance spectra, and extraction of information from the secondary, weaker nitrite absorbance peak. This approach allows for estimation of nitrite with a simple chemometric model and without sample dilution. These results are promising for a practical application of the UV sensor as an in situ nitrite measurement in a urine nitrification reactor given the exceptional quality of the nitrite estimates in comparison to previous studies. Copyright © 2015 Elsevier Ltd. All rights reserved.

  17. Complete nutrient recovery from source-separated urine by nitrification and distillation.

    Udert, K M; Wächter, M

    2012-02-01

    In this study we present a method to recover all nutrients from source-separated urine in a dry solid by combining biological nitrification with distillation. In a first process step, a membrane-aerated biofilm reactor was operated stably for more than 12 months, producing a nutrient solution with a pH between 6.2 and 7.0 (depending on the pH set-point), and an ammonium to nitrate ratio between 0.87 and 1.15 gN gN(-1). The maximum nitrification rate was 1.8 ± 0.3 gN m(-2) d(-1). Process stability was achieved by controlling the pH via the influent. In the second process step, real nitrified urine and synthetic solutions were concentrated in lab-scale distillation reactors. All nutrients were recovered in a dry powder except for some ammonia (less than 3% of total nitrogen). We estimate that the primary energy demand for a simple nitrification/distillation process is four to five times higher than removing nitrogen and phosphorus in a conventional wastewater treatment plant and producing the equivalent amount of phosphorus and nitrogen fertilizers. However, the primary energy demand can be reduced to values very close to conventional treatment, if 80% of the water is removed with reverse osmosis and distillation is operated with vapor compression. The ammonium nitrate content of the solid residue is below the limit at which stringent EU safety regulations for fertilizers come into effect; nevertheless, we propose some additional process steps that will increase the thermal stability of the solid product. Copyright © 2011 Elsevier Ltd. All rights reserved.

  18. Separation and Concentration of Succinic Adic from Multicomponent Aqueous Solutions by Nanofiltration Technique

    Antczak Jerzy

    2014-06-01

    Full Text Available This paper applies the determined suitability of nanofiltration (NF membrane separation for selective isolation and concentration of succinic acid from aqueous solutions which are post-fermentation multicomponent fluids. The study analyzed the influence of concentration and the pH of the separated solutions on the efficiency and selectivity of NF process that runs in a module equipped with a ceramic membrane. Moreover, the effect of applied trans-membrane pressure on the retention of succinic acid and sodium succinate has been studied. The investigations have shown that in the used NF module the retention of succinic acid salt is equal almost 50% in the case of a three-component model solution, although the degree of retention depends on both the transmembrane pressure and the initial concentration of separated salt.

  19. Quality of Life after Ventral Hernia Repair with Endoscopic Component Separation Technique

    Thomsen, C Ø; Brøndum, T L; Jørgensen, Lars Nannestad

    2016-01-01

    of the hernia size. Demographic data, operative information, and postoperative complications were recorded. All patients completed two similar questionnaires regarding their function level, cosmetic satisfaction, analgesic medication, alcohol consumption, and self-estimated physical and mental health before...... center operated on with endoscopic components separation. MATERIAL AND METHODS: A total of 19 consecutive patients scheduled for open hernia repair with endoscopic components separation from October 2010 to June 2012 were included. All procedures included endoscopic components separation because...... and after the hernia repair. Patients were assessed as outpatient median 2 months and 16 months after operation for exclusion of hernia recurrence and completion of the postoperative questionnaire. RESULTS AND CONCLUSIONS: Operating room time was median 204 min and correlated significantly with the hernia...

  20. Pyrohydrolytic separation technique for fluoride and chloride from radioactive liquid wastes

    Sawant, R.M.; Mahajan, M.A.; Shah, D.J.; Thakur, U.K.; Ramakumar, K.L.

    2009-01-01

    A rapid method for simultaneous determination of fluorine and chlorine in liquid samples with ion chromatography after pyrohydrolysis separation was proposed for routine analysis. The elements were separated from radioactive liquid sample by pyrohydrolysis and were subsequently determined with ion chromatography. Total time taken to determine these elements is about 45 min including 30 min for the pyrohydrolysis and 15 min for ion chromatography. The results of recovery tests ranged 95% or above. The limits of detection for F and Cl are 0.5 and 0.8 mgkg -1 , respectively. (author)

  1. Pyrohydrolytic separation technique for fluoride and chloride from radioactive liquid wastes

    Sawant, R.M.; Mahajan, M.A.; Shah, D.J.; Thakur, U.K.; Ramakumar, K.L.

    2011-01-01

    A rapid method for simultaneous determination of fluorine and chlorine in radioactive liquid wastes with ion chromatography after pyrohydrolysis separation was proposed for routine analysis. The elements were separated from radioactive liquid wastes by pyrohydrolysis and were subsequently determined with ion chromatography. Total time taken to determine these elements is about 45 min including 30 min for the pyrohydrolysis and 15 min for ion chromatography. The results of recovery tests ranged 95% or above. The limits of detection for F and Cl are 0.5 and 0.8 mg kg -1 , respectively. (author)

  2. Microlens Array Laser Transverse Shaping Technique for Photoemission Electron Source

    Halavanau, A. [Northern Illinois Univ., DeKalb, IL (United States); Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Ha, G. [Argonne National Lab. (ANL), Argonne, IL (United States); Pohang Univ. of Science and Technology (POSTECH) (Korea, Republic of); Qiang, G. [Argonne National Lab. (ANL), Argonne, IL (United States); Tsinghua Univ., Beijing (China); Gai, W. [Argonne National Lab. (ANL), Argonne, IL (United States); Power, J. [Argonne National Lab. (ANL), Argonne, IL (United States); Piot, P. [Northern Illinois Univ., DeKalb, IL (United States); Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Wisniewski, E. [Argonne National Lab. (ANL), Argonne, IL (United States); Edstrom, D. [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Ruan, J. [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Santucci, J. [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States)

    2016-09-06

    A common issue encountered in photoemission electron sources used in electron accelerators is distortion of the laser spot due to non ideal conditions at all stages of the amplification. Such a laser spot at the cathode may produce asymmetric charged beams that will result in degradation of the beam quality due to space charge at early stages of acceleration and fail to optimally utilize the cathode surface. In this note we study the possibility of using microlens arrays to dramatically improve the transverse uniformity of the drive laser pulse on UV photocathodes at both Fermilab Accelerator Science \\& Technology (FAST) facility and Argonne Wakefield Accelerator (AWA). In particular, we discuss the experimental characterization of the homogeneity and periodic patterned formation at the photocathode. Finally, we compare the experimental results with the paraxial analysis, ray tracing and wavefront propagation software.

  3. Biomimetic polymers in analytical chemistry. Part 1: preparation and applications of MIP (Molecularly Imprinted Polymers) in extraction and separation techniques

    Tarley, Cesar Ricardo Teixeira; Sotomayor, Maria del Pilar Taboada; Kubota, Lauro Tatsuo

    2005-01-01

    MIPs are synthetic polymers that are used as biomimetic materials simulating the mechanism verified in natural entities such as antibodies and enzymes. Although MIPs have been successfully used as an outstanding tool for enhancing the selectivity or different analytical approaches, such as separation science and electrochemical and optical sensors, several parameters must be optimized during their synthesis. Therefore, the state-of-the-art of MIP production as well as the different polymerization methods are discussed. The potential selectivity of MIPs in the extraction and separation techniques focusing mainly on environmental, clinical and pharmaceutical samples as applications for analytical purposes is presented. (author)

  4. Extended automated separation techniques in destructive neutron activation analysis; application to various biological materials, including human tissues and blood

    Tjioe, P.S.; Goeij, J.J.M. de; Houtman, J.P.W.

    1976-09-01

    Neutron activation analysis may be performed as a multi-element and low-level technique for many important trace elements in biological materials, provided that post-irradiation chemical separations are applied. This paper describes a chemical separation consisting of automated procedures for destruction, distillation, and anion-chromatography. The system developed enables the determination of 14 trace elements in biological materials, viz. antimony, arsenic, bromine, cadmium, chromium, cobalt, copper, gold, iron, mercury, molybdenum, nickel, selenium, and zinc. The aspects of sample preparation, neutron irradiation, gamma-spectrum evaluation, and blank-value contribution are also discussed

  5. Property-close source separation of hazardous waste and waste electrical and electronic equipment - A Swedish case study

    Bernstad, Anna; Cour Jansen, Jes la; Aspegren, Henrik

    2011-01-01

    Through an agreement with EEE producers, Swedish municipalities are responsible for collection of hazardous waste and waste electrical and electronic equipment (WEEE). In most Swedish municipalities, collection of these waste fractions is concentrated to waste recycling centres where households can source-separate and deposit hazardous waste and WEEE free of charge. However, the centres are often located on the outskirts of city centres and cars are needed in order to use the facilities in most cases. A full-scale experiment was performed in a residential area in southern Sweden to evaluate effects of a system for property-close source separation of hazardous waste and WEEE. After the system was introduced, results show a clear reduction in the amount of hazardous waste and WEEE disposed of incorrectly amongst residual waste or dry recyclables. The systems resulted in a source separation ratio of 70 wt% for hazardous waste and 76 wt% in the case of WEEE. Results show that households in the study area were willing to increase source separation of hazardous waste and WEEE when accessibility was improved and that this and similar collection systems can play an important role in building up increasingly sustainable solid waste management systems.

  6. Chemical characteristics and methane potentials of source-separated and pre-treated organic municipal solid waste

    Hansen, Trine Lund; Svärd, Å; Angelidaki, Irini

    2003-01-01

    A research project has investigated the biogas potential of pre-screened source-separated organic waste. Wastes from five Danish cities have been pre-treated by three methods: screw press; disc screen; and shredder and magnet. This paper outlines the sampling procedure used, the chemical...... composition of the wastes and the estimated methane potentials....

  7. Anaerobic treatment as a core technology for energy, nutrients and water from source-separated domestic waste(water)

    Zeeman, G.; Kujawa, K.; Mes, de T.Z.D.; Graaff, de M.S.; Abu-Ghunmi, L.N.A.H.; Mels, A.R.; Meulman, B.; Temmink, B.G.; Buisman, C.J.N.; Lier, van J.B.; Lettinga, G.

    2008-01-01

    Based on results of pilot scale research with source-separated black water (BW) and grey water (GW), a new sanitation concept is proposed. BW and GW are both treated in a UASB (-septic tank) for recovery of CH4 gas. Kitchen waste is added to the anaerobic BW treatment for doubling the biogas

  8. A Systematic Review of Techniques and Sources of Big Data in the Healthcare Sector.

    Alonso, Susel Góngora; de la Torre Díez, Isabel; Rodrigues, Joel J P C; Hamrioui, Sofiane; López-Coronado, Miguel

    2017-10-14

    The main objective of this paper is to present a review of existing researches in the literature, referring to Big Data sources and techniques in health sector and to identify which of these techniques are the most used in the prediction of chronic diseases. Academic databases and systems such as IEEE Xplore, Scopus, PubMed and Science Direct were searched, considering the date of publication from 2006 until the present time. Several search criteria were established as 'techniques' OR 'sources' AND 'Big Data' AND 'medicine' OR 'health', 'techniques' AND 'Big Data' AND 'chronic diseases', etc. Selecting the paper considered of interest regarding the description of the techniques and sources of Big Data in healthcare. It found a total of 110 articles on techniques and sources of Big Data on health from which only 32 have been identified as relevant work. Many of the articles show the platforms of Big Data, sources, databases used and identify the techniques most used in the prediction of chronic diseases. From the review of the analyzed research articles, it can be noticed that the sources and techniques of Big Data used in the health sector represent a relevant factor in terms of effectiveness, since it allows the application of predictive analysis techniques in tasks such as: identification of patients at risk of reentry or prevention of hospital or chronic diseases infections, obtaining predictive models of quality.

  9. Pathogens and pharmaceuticals in source-separated urine in eThekwini, South Africa.

    Bischel, Heather N; Özel Duygan, Birge D; Strande, Linda; McArdell, Christa S; Udert, Kai M; Kohn, Tamar

    2015-11-15

    In eThekwini, South Africa, the production of agricultural fertilizers from human urine collected from urine-diverting dry toilets is being evaluated at a municipality scale as a way to help finance a decentralized, dry sanitation system. The present study aimed to assess a range of human and environmental health hazards in source-separated urine, which was presumed to be contaminated with feces, by evaluating the presence of human pathogens, pharmaceuticals, and an antibiotic resistance gene. Composite urine samples from households enrolled in a urine collection trial were obtained from urine storage tanks installed in three regions of eThekwini. Polymerase chain reaction (PCR) assays targeted 9 viral and 10 bacterial human pathogens transmitted by the fecal-oral route. The most frequently detected viral pathogens were JC polyomavirus, rotavirus, and human adenovirus in 100%, 34% and 31% of samples, respectively. Aeromonas spp. and Shigella spp. were frequently detected gram negative bacteria, in 94% and 61% of samples, respectively. The gram positive bacterium, Clostridium perfringens, which is known to survive for extended times in urine, was found in 72% of samples. A screening of 41 trace organic compounds in the urine facilitated selection of 12 priority pharmaceuticals for further evaluation. The antibiotics sulfamethoxazole and trimethoprim, which are frequently prescribed as prophylaxis for HIV-positive patients, were detected in 95% and 85% of samples, reaching maximum concentrations of 6800 μg/L and 1280 μg/L, respectively. The antiretroviral drug emtricitabine was also detected in 40% of urine samples. A sulfonamide antibiotic resistance gene (sul1) was detected in 100% of urine samples. By coupling analysis of pathogens and pharmaceuticals in geographically dispersed samples in eThekwini, this study reveals a range of human and environmental health hazards in urine intended for fertilizer production. Collection of urine offers the benefit of

  10. Blind source separation based on time-frequency morphological characteristics for rigid acoustic scattering by underwater objects

    Yang, Yang; Li, Xiukun

    2016-06-01

    Separation of the components of rigid acoustic scattering by underwater objects is essential in obtaining the structural characteristics of such objects. To overcome the problem of rigid structures appearing to have the same spectral structure in the time domain, time-frequency Blind Source Separation (BSS) can be used in combination with image morphology to separate the rigid scattering components of different objects. Based on a highlight model, the separation of the rigid scattering structure of objects with time-frequency distribution is deduced. Using a morphological filter, different characteristics in a Wigner-Ville Distribution (WVD) observed for single auto term and cross terms can be simplified to remove any cross-term interference. By selecting time and frequency points of the auto terms signal, the accuracy of BSS can be improved. An experimental simulation has been used, with changes in the pulse width of the transmitted signal, the relative amplitude and the time delay parameter, in order to analyzing the feasibility of this new method. Simulation results show that the new method is not only able to separate rigid scattering components, but can also separate the components when elastic scattering and rigid scattering exist at the same time. Experimental results confirm that the new method can be used in separating the rigid scattering structure of underwater objects.

  11. Utilization of the safety functional analysis techniques to optimize the separation requirements in case of fire

    Alvarez, L.M.

    1983-01-01

    The present philosophy for the fire protection of the safe shutdown capability in nuclear power plants is based on the separation of the safety-related systems in different fire areas in such a way that the redundant systems are not subject to damage from a single fire risk. The purpose ofthis paper is to show the experience gained in the application of a symmetric method of analysis to minimize the number of fire barriers being compatible with the regulatory requirements and with capability of achieving and maintaining the safe plant shutdown in the event of a fire. As a conclusion of the analysis, the separation criteria for the divisions involved in the safe plant shutdown are obtained

  12. Stable Isotope Quantitative N-Glycan Analysis by Liquid Separation Techniques and Mass Spectrometry.

    Mittermayr, Stefan; Albrecht, Simone; Váradi, Csaba; Millán-Martín, Silvia; Bones, Jonathan

    2017-01-01

    Liquid phase separation analysis and subsequent quantitation remains a challenging task for protein-derived oligosaccharides due to their inherent structural complexity and diversity. Incomplete resolution or co-detection of multiple glycan species complicates peak area-based quantitation and associated statistical analysis when optical detection methods are used. The approach outlined herein describes the utilization of stable isotope variants of commonly used fluorescent tags that allow for mass-based glycan identification and relative quantitation following separation by liquid chromatography (LC) or capillary electrophoresis (CE). Comparability assessment of glycoprotein-derived oligosaccharides is performed by derivatization with commercially available isotope variants of 2-aminobenzoic acid or aniline and analysis by LC- and CE-mass spectrometry. Quantitative information is attained from the extracted ion chromatogram/electropherogram ratios generated from the light and heavy isotope clusters.

  13. Analytical-scale separations of lanthanides : a review of techniques and fundamentals

    Nash, K. L.; Jensen, M. P.

    1999-01-01

    Separations chemistry is at the heart of most analytical procedures to determine the rare earth content of both man-made and naturally occurring materials. Such procedures are widely used in mineral exploration, fundamental geology and geochemistry, material science, and in the nuclear industry. Chromatographic methods that rely on aqueous solutions containing complexing agents sensitive to the lanthanide cationic radius and cation-exchange phase transfer reactions (using a variety of different solid media) have enjoyed the greatest success for these procedures. In this report, they will briefly summarize the most important methods for completing such analyses. they consider in some detail the basic aqueous (and two-phase) solution chemistry that accounts for separations that work well and offer explanations for why others are less successful

  14. New separation techniques of cesium by redox type ion exchange materials

    Tanihara, Koichi

    1998-01-01

    RIECS method, new cesium separation method, was developed in which a porous strong base anionic exchanger with copper ferrocyanide (CuFC) and inhibitor were used. Cesium could be separated from the high concentration nitric solution. By developing new impregnation method, large amount of CuFC was impregnated into the micropolar porous resin and silica gel pores. KFC adhered to outside of pores was recovered. Good complex with CuFC was prepared by use of copper chloride in ethyl alcohol solution. The adsorption ratio of cesium increased radically to 80% level in the very small range of hydrazine concentration 1.7 to 2.4x10 -4 M. The adsorption-desorption ratio of cesium did not decrease by repeating it seven times. The glassificated materials decreased large amount of γ-ray unless increase of volume could be produced by built RIECS method in the high level waste processing system. (S.Y.)

  15. Identification of barley proteins and glycoproteins by various separation techniques and MALDI MS

    Laštovičková, Markéta; Bezouška, Karel; Marchetti, M.; Allmaier, G.; Chmelík, Josef

    2005-01-01

    Roč. 99, S (2005), s307-s309 ISSN 0009-2770. [Meeting on Chemistry and Life /3./. Brno, 20.09.2005-22.09.2005] R&D Projects: GA MŠk 1M0570 Institutional research plan: CEZ:AV0Z40310501 Keywords : glycoprotein * SDS - PAGE * lectin chromatography Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 0.445, year: 2005

  16. Separation of actinium-227 from its daughter products by cationic resins technique

    Nastasi, M.J.C.

    1976-01-01

    A method for separating actinium-227 from its daughter products based on ion exchange principle is shown. Radionuclides mixture in perchloric acid 8,5 N and chloridric acid 0,5 N medium pass by a cationic resin column. Thorium-227 and actinium-227, which are retained by the resin, are eluted with nitric acid 6 N which releases actinium-227 while oxalic acid 7% is used for thorium-227 elution [pt

  17. Magnetic particle separation technique: a reliable and simple tool for RIA/IRMA and quantitative PCR assay

    Shen Rongsen; Shen Decun

    1998-01-01

    Five types of magnetic particles without or with aldehyde, amino and carboxyl functional groups, respectively were used to immobilize first or second antibody by three models, i. e. physical adsorption, chemical coupling and immuno-affinity, forming four types of magnetic particle antibodies. The second antibody immobilized on polyacrolein magnetic particles through aldehyde functional groups and the first antibodies immobilized on carboxylic polystyrene magnetic particles through carboxyl functional groups were recommended to apply to RIAs and/or IRMAs. Streptavidin immobilized on commercial magnetic particles through amino functional groups was successfully applied to separating specific PCR product for quantification of human cytomegalovirus. In the paper typical data on reliability of these magnetic particle ligands were reported and simplicity of the magnetic particle separation technique was discussed. The results showed that the technique was a reliable and simple tool for RIA/IRMA and quantitative PCR assay. (author)

  18. Separation techniques for low-level determination of actinides in soil samples

    Eikenberg, J. [Paul Scherrer Institute, Department Logistics for Radiation Safety and Security, CH-5232 Villigen (Switzerland)], E-mail: jost.eikenberg@psi.ch; Jaeggi, M.; Beer, H.; Ruethi, M.; Zumsteg, I. [Paul Scherrer Institute, Department Logistics for Radiation Safety and Security, CH-5232 Villigen (Switzerland)

    2009-05-15

    The separation methods for soil samples applied at PSI are based on extraction chromatography and ion exchange. After sample leaching, the actinides are pre-concentrated via precipitation using oxalic acid. Besides the classical separation methods applying the extraction chromatographic resins U/TEVA{sup TM} (for U, Th), TRU{sup TM} (Pu, Am), new methods were recently implemented to increase the radiochemical recovery of particularly trivalent Am and Cm. These methods do not require initial reduction of Pu(IV) to Pu(III) but stabilize Pu on the tetravalent oxidation state using a mixture of NaNO{sub 2}/H{sub 2}O{sub 2} in strong acidic medium. The Pu-fraction is then fixed along with Th onto Dowex AG 1-X2 anion exchanger resin. Th is eluted via complexation with 10 M HCl, Pu via reduction with HI. The fractions of Am+Cm and U are loaded onto DGA{sup TM} resin. This resin shows extraordinary high distribution coefficients (k'-values) exceeding 10{sup 4} (for Am) in strong nitric acid medium. The separation between U and Am is obtained quantitatively by decreasing the HNO{sub 3} concentration from 3 to 0.25 M (stripping of the U-fraction) while Am can be easily eluted thereafter using 0.25 M HCl as complexation compound.

  19. Freeze-drying technology: A separation technique for liquid nuclear materials

    Musgrave, J.A.; Efurd, D.W.; Banar, J.C.

    1997-01-01

    Freeze-drying technology (FDT) has been around for several decades as a separation technology. Most commonly, FDT is associated with the processing of food, but the largest industrial-scale use of FDT is in the pharmaceutical industry. Through a Cooperative Research and Development Agreement (CRADA) with BOC Edwards Calumatic, we are demonstrating the feasibility of FDT as a waste minimization and pollution prevention technology. This is a novel and innovative application of FDT. In addition, we plan to demonstrate that the freeze-dried residue is an ideal feed material for ceramic stabilization of radioactive waste and excess fissile material. The objective of this work is to demonstrate the feasibility of FDT for the separation of complex radioactive and nonradioactive materials, including liquids, slurries, and sludges containing a wide variety of constituents in which the separation factors are >10 8 . This is the first application of FDT in which the condensate is of primary importance. Our focus is applying this technology to the elimination of radioactive liquid discharges from facilities at Los Alamos National Laboratory (LANL) and within the U.S. Department of Energy complex; however, successful demonstration will lead to nuclear industry-wide applications

  20. Liquid separation techniques coupled with mass spectrometry for chiral analysis of pharmaceuticals compounds and their metabolites in biological fluids.

    Erny, Guillaume L.; Cifuentes, Alejandro

    2006-01-01

    Determination of the chiral composition of drugs is nowadays a key step in order to determine purity, activity, bioavailability, biodegradation, etc, of pharmaceuticals. In this manuscript, works published for the last 5 years on the analysis of chiral drugs by liquid separation techniques coupled with mass spectrometry are reviewed. Namely, chiral analysis of pharmaceuticals including e.g., antiinflammatories, antihypertensives, relaxants, etc, by liquid chromatography-mass spectrometry and ...

  1. Computational Investigations of Inboard Flow Separation and Mitigation Techniques on Multi-Megawatt Wind Turbines

    Chow, Raymond

    The aerodynamic characteristics of the NREL 5-MW rotor have been examined using a Reynolds-averaged Navier-Stokes method, OVERFLOW2. A comprehensive off-body grid independence study has been performed. A strong dependence on the size of the near-body wake grid has been found. Rapid diffusion of the wake appears to generate an overprediction of power and thrust. A large, continuous near-wake grid at minimum of two rotor diameters downstream of the rotor appears to be necessary for accurate predictions of near-body forces. The NREL 5-MW rotor demonstrates significant inboard flow separation up to 30% of span. This separation appears to be highly three-dimensional, with a significant amount of radial flow increasing the size of the separated region outboard. Both integrated aerodynamic coefficients and detailed wake structures for the baseline NREL 5-MW rotor are in excellent agreement with results by Riso at Uinfinity = 8 and 11 m/s. A simple, continuous full-chord fence was applied at the maximum chord location of the blade, within the region of separation. This non-optimized device reduced the boundary-layer cross-flow and resulting separation, and increased rotor power capture by 0.9% and 0.6% at U infinity = 8 and 11 m/s, respectively. Suction side only fences perform similarly in terms of power capture but reduce the increase in rotor thrust. Fence heights from 0.5% to 17.5% of the maximum chord all demonstrate some level of effectiveness, with fences (1-2.5%cmax) showing similar performance gains to taller fences with smaller penalties in thrust. Performance in terms of power capture is not very sensitive to spanwise location when placed within the separation region. Blunt trailing edge modifications to the inboard region of the blade showed a relatively significant effect on rotor power. Over a large range of trailing edge thicknesses from hTE = 10 to 25%c, power was found to increase by 1.4%. Thrust increased proportionally with the thicknesses examined

  2. Waste disposal and households' heterogeneity. Identifying factors shaping attitudes towards source-separated recycling in Bogotá, Colombia.

    J Padilla, Alcides; Trujillo, Juan C

    2018-04-01

    Solid waste management in many cities of developing countries is not environmentally sustainable. People traditionally dispose of their solid waste in unsuitable urban areas like sidewalks and satellite dumpsites. This situation nowadays has become a serious public health problem in big Latin American conurbations. Among these densely-populated urban spaces, the Colombia's capital and main city stands out as a special case. In this study, we aim to identify the factors that shape the attitudes towards source-separated recycling among households in Bogotá. Using data from the Colombian Department of Statistics and Bogotá's multi-purpose survey, we estimated a multivariate Probit model. In general, our results show that the higher the household's socioeconomic class, the greater its effort for separating solid wastes. Likewise, our findings also allowed us to characterize household profiles regarding solid waste separation and considering each socioeconomic class. Among these profiles, we found that at lower socioeconomic classes, the attitudes towards solid waste separation are influenced by the use of Internet, the membership to an environmentalist organization, the level of education of the head of household and the homeownership. Hence, increasing the education levels within the poorest segment of the population, promoting affordable housing policies and facilitating Internet access for the vulnerable population could reinforce households' attitudes towards a greater source-separated recycling effort. Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. Closure of giant omphaloceles by the abdominal wall component separation technique in infants.

    Eijck, F.C. van; Blaauw, I. de; Bleichrodt, R.P.; Rieu, P.N.M.A.; Staak, F.H.J.M. van der; Wijnen, M.H.W.A.; Wijnen, R.M.H.

    2008-01-01

    BACKGROUND/PURPOSE: Several techniques have been described to repair giant omphaloceles. There is no procedure considered to be the criterion standard worldwide. The aim of the present prospective study was to analyze the early and late results of secondary closure of giant omphaloceles using the

  4. Using Essential Oils to Teach Advanced-Level Organic Chemistry Separation Techniques and Spectroscopy

    Bott, Tina M.; Wan, Hayley

    2013-01-01

    Students sometimes have difficulty grasping the importance of when and how basic distillation techniques, column chromatography, TLC, and basic spectroscopy (IR and NMR) can be used to identify unknown compounds within a mixture. This two-part experiment uses mixtures of pleasant-smelling, readily available terpenoid compounds as unknowns to…

  5. A Structured Grid Based Solution-Adaptive Technique for Complex Separated Flows

    Thornburg, Hugh; Soni, Bharat K.; Kishore, Boyalakuntla; Yu, Robert

    1996-01-01

    The objective of this work was to enhance the predictive capability of widely used computational fluid dynamic (CFD) codes through the use of solution adaptive gridding. Most problems of engineering interest involve multi-block grids and widely disparate length scales. Hence, it is desirable that the adaptive grid feature detection algorithm be developed to recognize flow structures of different type as well as differing intensity, and adequately address scaling and normalization across blocks. In order to study the accuracy and efficiency improvements due to the grid adaptation, it is necessary to quantify grid size and distribution requirements as well as computational times of non-adapted solutions. Flow fields about launch vehicles of practical interest often involve supersonic freestream conditions at angle of attack exhibiting large scale separate vortical flow, vortex-vortex and vortex-surface interactions, separated shear layers and multiple shocks of different intensity. In this work, a weight function and an associated mesh redistribution procedure is presented which detects and resolves these features without user intervention. Particular emphasis has been placed upon accurate resolution of expansion regions and boundary layers. Flow past a wedge at Mach=2.0 is used to illustrate the enhanced detection capabilities of this newly developed weight function.

  6. The Hurriclon technology; La technique Hurriclon de separation a force centrifuge

    Kaufmann, M. [PMT Zyclontechnik GmbH, Krems (Austria)

    2000-09-01

    Saving specific energy consumption is a main target in modem cement plants. But reducing pressure loss in cyclone systems results normally in a lesser separation efficiency. These two problems can be overcome by the use of a new system of guided vanes, called vortex finder vanes which can be also installed in existing cyclone systems. The obtained pressure loss reduction is higher than 30 %. Another development is the Hurriclon system which combines the above mentioned device with a double dip tube cyclone system. The advantage is a better separation efficiency at lower pressure losses leading to a higher production rate and therefore lower specific energy consumption as well as smaller filter units. The residual dust particles in the clean gas have also a significantly smaller size leading to less wear in the subsequent installations. The field of application encompasses all dedusting systems of cement plants starting after the mills or after the cooler, but also the preheater cyclones. In the case of upgrading of existing systems, the investment payback periods can be within some months. The paper shows the principles of these systems and several reference projects with guaranteed and obtained values regarding operation parameters. (author)

  7. Nonnegative Matrix Factor 2-D Deconvolution for Blind Single Channel Source Separation

    Schmidt, Mikkel N.; Mørup, Morten

    2006-01-01

    We present a novel method for blind separation of instruments in polyphonic music based on a non-negative matrix factor 2-D deconvolution algorithm. Using a model which is convolutive in both time and frequency we factorize a spectrogram representation of music into components corresponding...

  8. Prospects of Source-Separation-Based Sanitation Concepts: A Model-Based Study

    Tervahauta, T.H.; Trang Hoang,; Hernández, L.; Zeeman, G.; Buisman, C.J.N.

    2013-01-01

    Separation of different domestic wastewater streams and targeted on-site treatment for resource recovery has been recognized as one of the most promising sanitation concepts to re-establish the balance in carbon, nutrient and water cycles. In this study a model was developed based on literature data

  9. Raw mechanically separated chicken meat and salmon protein hydrolysate as protein sources in extruded dog food

    Tjernsbekk, M. T.; Tauson, A. H.; Kraugerud, O. F.

    2017-01-01

    Protein quality was evaluated for mechanically separated chicken meat (MSC) and salmon protein hydrolysate (SPH), and for extruded dog foods where MSC or SPH partially replaced poultry meal (PM). Apparent total tract digestibility (ATTD) of crude protein (CP) and amino acids (AA) in the protein...

  10. Photoacoustic Techniques for Trace Gas Sensing Based on Semiconductor Laser Sources

    Vincenzo Spagnolo

    2009-12-01

    Full Text Available The paper provides an overview on the use of photoacoustic sensors based on semiconductor laser sources for the detection of trace gases. We review the results obtained using standard, differential and quartz enhanced photoacoustic techniques.

  11. Modelling phase separation in Fe-Cr system using different atomistic kinetic Monte Carlo techniques

    Castin, N.; Bonny, G.; Terentyev, D.; Lavrentiev, M.Yu.; Nguyen-Manh, D.

    2011-01-01

    Atomistic kinetic Monte Carlo (AKMC) simulations were performed to study α-α' phase separation in Fe-Cr alloys. Two different energy models and two approaches to estimate the local vacancy migration barriers were used. The energy models considered are a two-band model Fe-Cr potential and a cluster expansion, both fitted to ab initio data. The classical Kang-Weinberg decomposition, based on the total energy change of the system, and an Artificial Neural Network (ANN), employed as a regression tool were used to predict the local vacancy migration barriers 'on the fly'. The results are compared with experimental thermal annealing data and differences between the applied AKMC approaches are discussed. The ability of the ANN regression method to accurately predict migration barriers not present in the training list is also addressed by performing cross-check calculations using the nudged elastic band method.

  12. A radiochemical separation of spallogenic 88Zr in the carrier-free state for radioisotopic photoneutron sources

    Whipple, R.E.; Grant, P.M.; Daniels, R.J.; Daniels, W.R.; O'Brien, H.A.Jr.

    1976-01-01

    As the precursor of its 88 Y daughter, 88 Zr could be advantageously included in the active component of the 88 Y-Be photoneutron source for several reasons. The spallation of Mo targets with medium-energy protons at LAMPF procedure has been developed to separate radiozirconium from the target material and various spallogenic impurities. 88 Zr can consequently be obtained carrier-free and in quantitative yield. (author)

  13. Method and apparatus for suppressing electron generation in a vapor source for isotope separation

    Janes, G.S.

    1979-01-01

    A system for applying accelerating forces to ionized particles of a vapor in a manner to suppress the flow of electron current from the vapor source. The accelerating forces are applied as an electric field in a configuration orthogonal to a magnetic field. The electric field is applied between one or more anodes in the plasma and one or more cathodes operated as electron emitting surfaces. The circuit for applying the electric field floats the cathodes with respect to the vapor source, thereby removing the vapor source from the circuit of electron flow through the plasma and suppressing the flow of electrons from the vapor source. The potential of other conducting structures contacting the plasma is controlled at or permitted to seek a level which further suppresses the flow of electron currents from the vapor source. Reducing the flow of electrons from the vapor source is particularly useful where the vapor is ionized with isotopic selectivity because it avoids superenergization of the vapor by the electron current

  14. Production of monoclonal antibodies for use in immunoassays based on the magnetizable solid phase separation technique

    Charoensiriwatana, W.; Janejai, N.; Krasao, P.

    1996-01-01

    Monoclonal antibodies to TSH were produced by using mouse-ascites techniques. Various methods for purifying the antibody from the ascetic fluid have been tried in order to obtain an appropriate TSH kit production protocol. The purified antibodies were then immobilized on magnetizable cellulose for developing an IRMA for TSH. A detailed study of the assay system, including the stability of the magnetic adsorbent was made, which showed that the SCIPAc magnetizable cellulose is suitable for the production of TSH - Blood spot IRMA kits for use in the Neonatal hypothyroid screening programme to be launched in Thailand in the near future. (author). 4 refs, 12 figs, 2 tabs

  15. Multi-Antenna Data Collector for Smart Metering Networks with Integrated Source Separation by Spatial Filtering

    Quednau, Philipp; Trommer, Ralph; Schmidt, Lorenz-Peter

    2016-03-01

    Wireless transmission systems in smart metering networks share the advantage of lower installation costs due to the expandability of separate infrastructure but suffer from transmission problems. In this paper the issue of interference of wireless transmitted smart meter data with third party systems and data from other meters is investigated and an approach for solving the problem is presented. A multi-channel wireless m-bus receiver was developed to separate the desired data from unwanted interferers by spatial filtering. The according algorithms are presented and the influence of different antenna types on the spatial filtering is investigated. The performance of the spatial filtering is evaluated by extensive measurements in a realistic surrounding with several hundreds of active wireless m-bus transponders. These measurements correspond to the future environment for data-collectors as they took place in rural and urban areas with smart gas meters equipped with wireless m-bus transponders installed in almost all surrounding buildings.

  16. Use of oleaginous plants in phytotreatment of grey water and yellow water from source separation of sewage.

    Lavagnolo, Maria Cristina; Malagoli, Mario; Alibardi, Luca; Garbo, Francesco; Pivato, Alberto; Cossu, Raffaello

    2017-05-01

    Efficient and economic reuse of waste is one of the pillars of modern environmental engineering. In the field of domestic sewage management, source separation of yellow (urine), brown (faecal matter) and grey waters aims to recover the organic substances concentrated in brown water, the nutrients (nitrogen and phosphorous) in the urine and to ensure an easier treatment and recycling of grey waters. With the objective of emphasizing the potential of recovery of resources from sewage management, a lab-scale research study was carried out at the University of Padova in order to evaluate the performances of oleaginous plants (suitable for biodiesel production) in the phytotreatment of source separated yellow and grey waters. The plant species used were Brassica napus (rapeseed), Glycine max (soybean) and Helianthus annuus (sunflower). Phytotreatment tests were carried out using 20L pots. Different testing runs were performed at an increasing nitrogen concentration in the feedstock. The results proved that oleaginous species can conveniently be used for the phytotreatment of grey and yellow waters from source separation of domestic sewage, displaying high removal efficiencies of nutrients and organic substances (nitrogen>80%; phosphorous >90%; COD nearly 90%). No inhibition was registered in the growth of plants irrigated with different mixtures of yellow and grey waters, where the characteristics of the two streams were reciprocally and beneficially integrated. Copyright © 2016. Published by Elsevier B.V.

  17. Removal turbidity and separation of heavy metals using electrocoagulation-electroflotation technique

    Merzouk, B. [Departement d' Hydraulique, Universite Mohamed Boudiaf de M' sila (Algeria)], E-mail: mbelkov@yahoo.fr; Gourich, B. [Laboratoire de Genie des Procedes, Ecole Superieure de Technologie de Casablanca, B.P. 8012, Oasis (Morocco); Sekki, A. [Departement de Genie des Procedes, Universite Ferhat Abbas de Setif (Algeria); Madani, K.; Chibane, M. [Faculte des Sciences de la Nature et de la Vie, Universite A - Mira de Bejaia (Algeria)

    2009-05-15

    The electrocoagulation (EC) process was developed to overcome the drawbacks of conventional wastewater treatment technologies. This process is very effective in removing organic pollutants including dyestuff wastewater and allows for the reduction of sludge generation. The purposes of this study were to investigate the effects of the operating parameters, such as pH, initial concentration (C{sub 0}), duration of treatment (t), current density (j), interelectrode distance (d) and conductivity ({kappa}) on a synthetic wastewater in the batch electrocoagulation-electroflotation (EF) process. The optimal operating conditions were determined and applied to a textile wastewater and separation of some heavy metals. Initially a batch-type EC-EF reactor was operated at various current densities (11.55, 18.6, 35.94, 56.64, 74.07 and 91.5 mA/cm{sup 2}) and various interelectrode distance (1, 2 and 3 cm). For solutions with 300 mg/L of silica gel, high turbidity removal (89.54%) was obtained without any coagulants when the current density was 11.55 mA/cm{sup 2}, initial pH was 7.6, conductivity was 2.1 mS/cm, duration of treatment was 10 min and interelectrode distance was 1 cm. The application of the optimal operating parameters on a textile wastewater showed a high removal efficiency for various items: suspended solid (SS) 86.5%, turbidity 81.56%, biological oxygen demand (BOD{sub 5}) 83%, chemical oxygen demand (COD) 68%, and color over 92.5%. During the EC process under these conditions, we have studied the separation of some heavy metal ions such as iron (Fe), nickel (Ni), copper (Cu), zinc (Zn), lead (Pb) and cadmium (Cd) with different initial concentrations in the range of 50-600 mg/L and initial pH between 7.5 and 7.8. This allowed us to show that the kinetics of electrocoagulation-electroflotation is very quick (<15 min), and the removal rate reaches 95%.

  18. Removal turbidity and separation of heavy metals using electrocoagulation-electroflotation technique

    Merzouk, B.; Gourich, B.; Sekki, A.; Madani, K.; Chibane, M.

    2009-01-01

    The electrocoagulation (EC) process was developed to overcome the drawbacks of conventional wastewater treatment technologies. This process is very effective in removing organic pollutants including dyestuff wastewater and allows for the reduction of sludge generation. The purposes of this study were to investigate the effects of the operating parameters, such as pH, initial concentration (C 0 ), duration of treatment (t), current density (j), interelectrode distance (d) and conductivity (κ) on a synthetic wastewater in the batch electrocoagulation-electroflotation (EF) process. The optimal operating conditions were determined and applied to a textile wastewater and separation of some heavy metals. Initially a batch-type EC-EF reactor was operated at various current densities (11.55, 18.6, 35.94, 56.64, 74.07 and 91.5 mA/cm 2 ) and various interelectrode distance (1, 2 and 3 cm). For solutions with 300 mg/L of silica gel, high turbidity removal (89.54%) was obtained without any coagulants when the current density was 11.55 mA/cm 2 , initial pH was 7.6, conductivity was 2.1 mS/cm, duration of treatment was 10 min and interelectrode distance was 1 cm. The application of the optimal operating parameters on a textile wastewater showed a high removal efficiency for various items: suspended solid (SS) 86.5%, turbidity 81.56%, biological oxygen demand (BOD 5 ) 83%, chemical oxygen demand (COD) 68%, and color over 92.5%. During the EC process under these conditions, we have studied the separation of some heavy metal ions such as iron (Fe), nickel (Ni), copper (Cu), zinc (Zn), lead (Pb) and cadmium (Cd) with different initial concentrations in the range of 50-600 mg/L and initial pH between 7.5 and 7.8. This allowed us to show that the kinetics of electrocoagulation-electroflotation is very quick (<15 min), and the removal rate reaches 95%

  19. Investigations of Orchestra Auralizations Using the Multi-Channel Multi-Source Auralization Technique

    Vigeant, Michelle; Wang, Lily M.; Rindel, Jens Holger

    2008-01-01

    a multi-channel multi-source auralization technique, involving individual five-channel anechoic recordings of each instrumental part of two symphonies. In the first study, these auralizations were subjectively compared to orchestra auralizations made using (a) a single omni-directional source, (b......) a surface source, and (c) single-channel multi-source method. Results show that the multi-source auralizations were rated to be more realistic than the surface source ones and to have larger source width than the single omni-directional source auralizations. No significant differences were found between......Room acoustics computer modeling is a tool for generating impulse responses and auralizations from modeled spaces. The auralizations are commonly made from a single-channel anechoic recording of solo instruments. For this investigation, auralizations of an entire orchestra were created using...

  20. Expanded separation technique for chlorophyll metabolites in Oriental tobacco leaf using non aqueous reversed phase chromatography.

    Ishida, Naoyuki

    2011-08-26

    An improved separation method for chlorophyll metabolites in Oriental tobacco leaf was developed. While Oriental leaf still gives the green color even after the curing process, little attention has been paid to the detailed composition of the remaining green pigments. This study aimed to identify the green pigments using non aqueous reversed phase chromatography (NARPC). To this end, liquid chromatograph (LC) equipped with a photo diode array detector (DAD) and an atmospheric pressure chemical ionization/mass spectrometer (APCI/MSD) was selected, because it is useful for detecting low polar non-volatile compounds giving green color such as pheophytin a. Identification was based on the wavelength spectrum, mass spectrum and retention time, comparing the analytes in Oriental leaf with the commercially available and synthesized components. Consequently, several chlorophyll metabolites such as hydroxypheophytin a, solanesyl pheophorbide a and solanesyl hydroxypheophorbide a were newly identified, in addition to typical green pigments such as chlorophyll a and pheophytin a. Chlorophyll metabolites bound to solanesol were considered the tobacco specific components. NARPC expanded the number of detectable low polar chlorophyll metabolites in Oriental tobacco leaf. Copyright © 2011 Elsevier B.V. All rights reserved.

  1. Electrophoretic separation techniques and their hyphenation to mass spectrometry in biological inorganic chemistry.

    Holtkamp, Hannah; Grabmann, Gerlinde; Hartinger, Christian G

    2016-04-01

    Electrophoretic methods have been widely applied in research on the roles of metal complexes in biological systems. In particular, CE, often hyphenated to a sensitive MS detector, has provided valuable information on the modes of action of metal-based pharmaceuticals, and more recently new methods have been added to the electrophoretic toolbox. The range of applications continues to expand as a result of enhanced CE-to-MS interfacing, with sensitivity often at picomolar level, and evolved separation modes allowing for innovative sample analysis. This article is a followup to previous reviews about CE methods in metallodrug research (Electrophoresis, 2003, 24, 2023-2037; Electrophoresis, 2007, 28, 3436-3446; Electrophoresis, 2012, 33, 622-634), also providing a comprehensive overview of metal species studied by electrophoretic methods hyphenated to MS. It highlights the latest CE developments, takes a sneak peek into gel electrophoresis, traces biomolecule labeling, and focuses on the importance of early-stage drug development. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. The Use of Isotope Techniques to Separate of Hydrography Components. Case Study: Ankara-Guvenc Basin

    Tekeli, Y.I.; Sorman, A.U.; Sayin, M.

    2002-01-01

    In this research, a stable environmental isotope study was carried out from analysis of water samples collected from rainfall, runoff (total discharge), springs (subsurface flows), and wells (ground waters)in Ankara-Guevenc basin having a drainage area of about 16.125 km 2 between 1996-2000. The aim of the study was to investigate the rainfall-runoff relationship for the basin. Recorded total ten discharge hydrographs are separated to their components using stable isotopes (Oxygen-18, Deuterium) contents. Among these samples, unit hydrographs from two one-peak storm hydrographs were derived using both isotope and graphical methods, and the derived unit hydrographs values including peaks were compared. Peak values of 10 and 20 minutes unit hydrographs of the basin derived by using isotope method (Q p = 1322 1/s and Q p = 1327 l/s) are compared with those of graphical method (Q p = 1656 1/s, and Q p = 1250 1/s) using Barnes semi-log approach. It was found out that, the contribution of subsurface flow which is component of total discharge hydrograph and originating from various sub layers are important in the total flow of basin using isotope method of approach

  3. Point source search techniques in ultra high energy gamma ray astronomy

    Alexandreas, D.E.; Biller, S.; Dion, G.M.; Lu, X.Q.; Yodh, G.B.; Berley, D.; Goodman, J.A.; Haines, T.J.; Hoffman, C.M.; Horch, E.; Sinnis, C.; Zhang, W.

    1993-01-01

    Searches for point astrophysical sources of ultra high energy (UHE) gamma rays are plagued by large numbers of background events from isotropic cosmic rays. Some of the methods that have been used to estimate the expected number of background events coming from the direction of a possible source are found to contain biases. Search techniques that avoid this problem are described. There is also a discussion of how to optimize the sensitivity of a search to emission from a point source. (orig.)

  4. Laboratory testing of a room temperature separation technique as part of a method for the reconditioning of bituminised waste

    Impens, N.

    2009-01-01

    At the Belgian Nuclear Research Center SCK-CEN, a research project has been finalised on the possible alternatives to re-treat so-called homogeneous bituminised waste such as Eurobitum. One way to retreat this type of waste would be plasma-incineration. Preliminary results showed that a very stable final vitrified waste can be obtained comparable to the stability of R7-T7 reference waste glass, and that the waste volume would be reduced to 75 percent of the original volume. The major disadvantages of this retreatment technique is the high-tech and high cost plasma installation needed and the safety aspects related to the higher radioactivity content of this waste type. The technique proposed in this paper is based on the dissolution of the bitumen in an organic solvent and the subsequent extraction of nitrates in water leading to the separation of (1) an organic effluent containing the maltenes, (2) an aqueous effluent containing the nitrates and (3) the final waste containing the asphaltene fraction and water insoluble salts including most of the radionuclides. This paper describes the lab-scale results of a room temperature separation technique applied to real radioactive Eurobitum samples, sampled from a drum that was produced in 1981

  5. Separating contributions from natural and anthropogenic sources in atmospheric methane from the Black Sea region, Romania

    Cuna, Stela; Pendall, Elise; Miller, John B.; Tans, Pieter P.; Dlugokencky, Ed; White, James W.C.

    2008-01-01

    The Danube Delta-Black Sea region of Romania is an important wetland, and this preliminary study evaluates the significance of this region as a source of atmospheric CH 4 . Measurements of the mixing ratio and δ 13 C in CH 4 are reported from air and water samples collected at eight sites in the Danube Delta. High mixing ratios of CH 4 were found in air (2500-14,000 ppb) and dissolved in water samples (∼1-10 μmol L -1 ), demonstrating that the Danube Delta is an important natural source of CH 4 . The intercepts on Keeling plots of about -62 per mille show that the main source of CH 4 in this region is microbial, probably resulting primarily from acetate fermentation. Atmospheric CH 4 and CO data from the NOAA/ESRL (National Oceanic and Atmospheric Administration/Earth System Research Laboratory) were used to make a preliminary estimate of biogenic CH 4 at the Black Sea sampling site at Constanta (BSC). These data were used to calculate ratios of CH 4 /CO in air samples, and using an assumed CH 4 /CO anthropogenic emissions ratio of 0.6, fossil fuel emissions at BSC were estimated. Biogenic CH 4 emissions were then estimated by a simple mass balance approach. Keeling plots of well-mixed air from the BSC site suggested a stronger wetland source in summer and a stronger fossil fuel source in winter

  6. Kinetics of Cu (II) separation by ion flotation techniques, in cells with flexible spargers

    Reyes, M.; Tavera, F. J.; Escudero, R.; Patino, F.; Salinas, E.; Rivera, I.

    2010-01-01

    This research studies and experimentally determines the kinetic parameters and effect of modifying the hydrodynamics and chemical conditions of the air-liquid dispersions during the Cu (II) extraction by ion flotation techniques in cells with porous spargers. Results show that the elimination of Cu (II) from solution can be carried out by ion flotation in one stage, obtaining efficiencies of 68% and 56% for the flat and cylindrical sparger respectively with a xanthate concentration of 0,02 g/l. In multistage systems five cells, recoveries over 92 % were achieved for both sparger geometries. The behavior of the flotation apparent kinetic constant is linear to the parameters that characterize dispersion (Jg, eg y Db), until a point is achieved where the process instability makes the system inoperable. The results show that removing base metal ions by ion flotation is strongly affected by the following factors: collector concentration [C], Jg, eg, Db, Jl and Sb. (Author) 20 refs

  7. Gaussian process based independent analysis for temporal source separation in fMRI

    Hald, Ditte Høvenhoff; Henao, Ricardo; Winther, Ole

    2017-01-01

    Functional Magnetic Resonance Imaging (fMRI) gives us a unique insight into the processes of the brain, and opens up for analyzing the functional activation patterns of the underlying sources. Task-inferred supervised learning with restrictive assumptions in the regression set-up, restricts...... the exploratory nature of the analysis. Fully unsupervised independent component analysis (ICA) algorithms, on the other hand, can struggle to detect clear classifiable components on single-subject data. We attribute this shortcoming to inadequate modeling of the fMRI source signals by failing to incorporate its...

  8. Liquid separation techniques coupled with mass spectrometry for chiral analysis of pharmaceuticals compounds and their metabolites in biological fluids.

    Erny, G L; Cifuentes, A

    2006-02-24

    Determination of the chiral composition of drugs is nowadays a key step in order to determine purity, activity, bioavailability, biodegradation, etc., of pharmaceuticals. In this article, works published for the last 5 years on the analysis of chiral drugs by liquid separation techniques coupled with mass spectrometry are reviewed. Namely, chiral analysis of pharmaceuticals including, e.g., antiinflammatories, antihypertensives, relaxants, etc., by liquid chromatography-mass spectrometry and capillary electrophoresis-mass spectrometry are included. The importance and interest of the analysis of the enantiomers of the active compound and its metabolites in different biological fluids (plasma, urine, cerebrospinal fluid, etc.) are also discussed.

  9. Time-domain beamforming and blind source separation speech input in the car environment

    Bourgeois, Julien

    2009-01-01

    The development of computer and telecommunication technologies led to a revolutioninthewaythatpeopleworkandcommunicatewitheachother.One of the results is that large amount of information will increasingly be held in a form that is natural for users, as speech in natural language. In the presented work, we investigate the speech signal capture problem, which includes the separation of multiple interfering speakers using microphone arrays. Adaptive beamforming is a classical approach which has been developed since the seventies. However it requires a double-talk detector (DTD) that interrupts th

  10. Time domain localization technique with sparsity constraint for imaging acoustic sources

    Padois, Thomas; Doutres, Olivier; Sgard, Franck; Berry, Alain

    2017-09-01

    This paper addresses source localization technique in time domain for broadband acoustic sources. The objective is to accurately and quickly detect the position and amplitude of noise sources in workplaces in order to propose adequate noise control options and prevent workers hearing loss or safety risk. First, the generalized cross correlation associated with a spherical microphone array is used to generate an initial noise source map. Then a linear inverse problem is defined to improve this initial map. Commonly, the linear inverse problem is solved with an l2 -regularization. In this study, two sparsity constraints are used to solve the inverse problem, the orthogonal matching pursuit and the truncated Newton interior-point method. Synthetic data are used to highlight the performances of the technique. High resolution imaging is achieved for various acoustic sources configurations. Moreover, the amplitudes of the acoustic sources are correctly estimated. A comparison of computation times shows that the technique is compatible with quasi real-time generation of noise source maps. Finally, the technique is tested with real data.

  11. Sources of uncertainty in individual monitoring for photographic,TL and OSL dosimetry techniques

    Ferreira, Max S.; Silva, Everton R.; Mauricio, Claudia L.P., E-mail: max.das.ferreira@gmail.com, E-mail: everton@ird.gov.br, E-mail: claudia@ird.gov.br [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2015-07-01

    The identification of the uncertainty sources and their quantification is essential to the quality of any dosimetric results. If uncertainties are not stated for all dose measurements informed in the monthly dose report to the monitored radiation facilities, they need to be known. This study aims to analyze the influence of different sources of uncertainties associated with photographic, TL and OSL dosimetric techniques, considering the evaluation of occupational doses of whole-body exposure for photons. To identify the sources of uncertainty it was conducted a bibliographic review in specific documents that deal with operational aspects of each technique and the uncertainties associated to each of them. Withal, technical visits to individual monitoring services were conducted to assist in this identification. The sources of uncertainty were categorized and their contributions were expressed in a qualitative way. The process of calibration and traceability are the most important sources of uncertainties, regardless the technique used. For photographic dosimetry, the remaining important uncertainty sources are due to: energy and angular dependence; linearity of response; variations in the films processing. For TL and OSL, the key process for a good performance is respectively the reproducibility of the thermal and optical cycles. For the three techniques, all procedures of the measurement process must be standardized, controlled and reproducible. Further studies can be performed to quantify the contribution of the sources of uncertainty. (author)

  12. Separation of blended impulsive sources using an iterative estimation-subtraction algorithm

    Doulgeris, P.; Mahdad, A.; Blacquière, G.

    2010-01-01

    Traditional data acquisition practice dictates the existence of sufficient time intervals between the firing of sequential impulsive sources in the field. However, much attention has been drawn recently to the possibility of shooting in an overlapping fashion. Numerous publications have addressed

  13. Novel techniques for characterization of hydrocarbon emission sources in the Barnett Shale

    Nathan, Brian Joseph

    Changes in ambient atmospheric hydrocarbon concentrations can have both short-term and long-term effects on the atmosphere and on human health. Thus, accurate characterization of emissions sources is critically important. The recent boom in shale gas production has led to an increase in hydrocarbon emissions from associated processes, though the exact extent is uncertain. As an original quantification technique, a model airplane equipped with a specially-designed, open-path methane sensor was flown multiple times over a natural gas compressor station in the Barnett Shale in October 2013. A linear optimization was introduced to a standard Gaussian plume model in an effort to determine the most probable emission rate coming from the station. This is shown to be a suitable approach given an ideal source with a single, central plume. Separately, an analysis was performed to characterize the nonmethane hydrocarbons in the Barnett during the same period. Starting with ambient hourly concentration measurements of forty-six hydrocarbon species, Lagrangian air parcel trajectories were implemented in a meteorological model to extend the resolution of these measurements and achieve domain-fillings of the region for the period of interest. A self-organizing map (a type of unsupervised classification) was then utilized to reduce the dimensionality of the total multivariate set of grids into characteristic one-dimensional signatures. By also introducing a self-organizing map classification of the contemporary wind measurements, the spatial hydrocarbon characterizations are analyzed for periods with similar wind conditions. The accuracy of the classification is verified through assessment of observed spatial mixing ratio enhancements of key species, through site-comparisons with a related long-term study, and through a random forest analysis (an ensemble learning method of supervised classification) to determine the most important species for defining key classes. The hydrocarbon

  14. Ion-source dependence of the distributions of internuclear separations in 2-MeV HeH+ beams

    Kanter, E.P.; Gemmell, D.S.; Plesser, I.; Vager, Z.

    1981-01-01

    Experiments involving the use of MeV molecular-ion beams have yielded new information on atomic collisions in solids. A central part of the analyses of such experiments is a knowledge of the distribution of internuclear separations contained in the incident beam. In an attempt to determine how these distributions depend on ion-source gas conditions, we have studied foil-induced dissociations of H 2+ , H 3+ , HeH + , and OH 2+ ions. Although changes of ion-source gas compositions and pressure were found to have no measurable influence on the vibrational state populations of the beams reaching our target, for HeH + we found that beams produced in our rf source were vibrationally hotter than beams produced in a duoplasmatron. This was also seen in studies of neutral fragments and transmitted molecules

  15. A simple alkali-metal and noble gas ion source for SIMS equipments with mass separation of the primary ions

    Duesterhoeft, H.; Pippig, R.

    1986-01-01

    An alkali-metal ion source working without a store of alkali-metals is described. The alkali-metal ions are produced by evaporation of alkali salts and ionization in a low-voltage arc discharge stabilized with a noble gas plasma or in the case of small alkali-metal ion currents on the base of the well known thermic ionization at a hot tungsten wire. The source is very simple in construction and produces a stable ion current of 0.3 μA for more than 100 h. It is possible to change the ion species in a short time. This source is applicable to all SIMS equipments using mass separation for primary ions. (author)

  16. Principles, techniques and recent advances in fine particle aggregation for solid-liquid separation

    Somasundaran, P.; Vasudevan, T.V.

    1993-01-01

    Waste water discharged from various chemical and nuclear processing operations contains dissolved metal species that are highly toxic and, in some cases, radioactive. When the waste is acidic in nature, neutralization using reagents such as lime is commonly practiced to reduce both the acidity and the amount of waste (Kuyucak et al.). The sludge that results from the neutralization process contains metal oxide or hydroxide precipitates that are colloidal in nature and is highly stable. Destabilization of colloidal suspensions can be achieved by aggregation of fines into larger sized agglomerates. Aggregation of fines is a complex phenomenon involving a multitude of forces that control the interparticle interaction. In order to understand the colloidal behavior of suspensions a fundamental knowledge of physicochemical properties that determine the various forces is essential. In this review, a discussion of basic principles governing the aggregation of colloidal fines, various ways in which interparticle forces can be manipulated to achieve the desired aggregation response and recent advances in experimental techniques to probe the interfacial characteristics that control the flocculation behavior are discussed

  17. Application of Resin in Pulp Technique for Ion Exchange Separation of Uranium from Alkaline Leachate

    Sreenivas, T.; Rajan, K.C.; Chakravartty, J.K.

    2014-01-01

    Conclusions: • Resin-in-pulp technique was applied for purification and enrichment of uranium values from a finely ground uranium ore leach slurry of alkaline nature using strong base anion exchange resin (size 500 - 675μm). • The chemical composition of the solution phase of the alkaline leach slurry (pH 9.5) was consisting of about 40 g/L of total dissolved solutes (TDS) predominantly with Na_2CO_3 and NaHCO_3 and minor levels of Na_2SO_4. The uranium content was only 730 mg/L and d50 of solids was 34μm. • Amongst the various commercially available resins studied PFA 4740 and 4783 having quaternary ammonium ion on polystyrene crosslink with divibyl benzez (DVB) gave best performance. The maximum loading capacity achieved in the RIP studies was about 60-65 g of U_3O_8/L of wet settled resin amounting to 98% of loading. This has necessitated 4 stages of counter-current extraction with overall contact time of 100 minutes at a resin to leach slurry volume ratio of about 1:50. Practically the entire uranium values loaded on the resin were eluted using NaCl. • The RIP process was found quite efficient for uranium bearing alkaline leach slurries.

  18. Separation of mouse testis cells on a Celsep (TM) apparatus and their usefulness as a source of high molecular weight DNA or RNA

    Wolgemuth, D. J.; Gizang-Ginsberg, E.; Engelmyer, E.; Gavin, B. J.; Ponzetto, C.

    1985-01-01

    The use of a self-contained unit-gravity cell separation apparatus for separation of populations of mouse testicular cells is described. The apparatus, a Celsep (TM), maximizes the unit area over which sedimentation occurs, reduces the amount of separation medium employed, and is quite reproducible. Cells thus isolated have been good sources for isolation of DNA, and notably, high molecular weight RNA.

  19. Development of method to chemical separation of gallium-67 by thermal diffusion technique

    Martins, Patricia de Andrade

    2012-01-01

    Radioisotopes of gallium have been studied and evaluated for medical applications since 1949. Over the past 50 years 67 Ga has been widely used in the diagnosis of various diseases, including acute and chronic inflammatory lesions, bacterial or sterile and several types of tumors. In Brazil 30% of clinics that provide services for Nuclear Medicine use 67 Ga citrate and the demand for 67 G a at IPEN-CNEN/SP is 37 GBq (1 Ci)/week. The 67 Ga presents physical half-life of 3.26 days (78 hours) and decays 100% by electron capture to stable 67 Zn. Its decay includes the emission of γ rays with energies of 93.3 keV (37%), 184.6 keV (20.4%), 300.2 keV (16.6%) and 888 keV (26%). In the past 67 Ga was produced by the reaction 68 Zn (p, 2n) 67 Ga at IPEN-CNEN/SP. After irradiation, the target was dissolved in concentrated HCl and the solution percolated through a cationic resin DOWEX 50W-X8, 200-400 mesh, conditioned with 10 mol L -1 HCl. Zinc, nickel and copper were eluted in 10 mol L -1 HCl and 67 Ga 3.5 mol L -1 HCl. The final product was obtained as 67 Ga citrate. This work presents a new, fast, direct and efficient method for the chemical separation of 67 G a by thermal diffusion (heating of the target) combined with concentrated acetic acid extraction. Purification was performed by ion exchange chromatography. Natural zinc electrodeposition was performed on nickel/copper plates as substrate and the zinc deposits were adherent to the substrate, slightly shiny and uniform. The targets were irradiated with 26 MeV protons and integrated current of 10 μA.h. After irradiation, the targets were heated at 300 deg C for 2 hours and placed in contact with concentrated acetic acid for 1 hour. The average yield of extraction of 67 Ga was (72 ± 10)%. This solution was evaporated and the residue was taken up in 0.5 mol L -1 NH 4 OH. The 67 G a was purified on cationic resin Dowex 50WX8 in NH 4 OH medium. The 67 Ga recovery was (98 ± 2)%. This solution was evaporated and taken up

  20. MAP-Based Underdetermined Blind Source Separation of Convolutive Mixtures by Hierarchical Clustering and -Norm Minimization

    Kellermann Walter

    2007-01-01

    Full Text Available We address the problem of underdetermined BSS. While most previous approaches are designed for instantaneous mixtures, we propose a time-frequency-domain algorithm for convolutive mixtures. We adopt a two-step method based on a general maximum a posteriori (MAP approach. In the first step, we estimate the mixing matrix based on hierarchical clustering, assuming that the source signals are sufficiently sparse. The algorithm works directly on the complex-valued data in the time-frequency domain and shows better convergence than algorithms based on self-organizing maps. The assumption of Laplacian priors for the source signals in the second step leads to an algorithm for estimating the source signals. It involves the -norm minimization of complex numbers because of the use of the time-frequency-domain approach. We compare a combinatorial approach initially designed for real numbers with a second-order cone programming (SOCP approach designed for complex numbers. We found that although the former approach is not theoretically justified for complex numbers, its results are comparable to, or even better than, the SOCP solution. The advantage is a lower computational cost for problems with low input/output dimensions.

  1. Production of monozygotic twin calves using the blastomere separation technique and Well of the Well culture system.

    Tagawa, M; Matoba, S; Narita, M; Saito, N; Nagai, T; Imai, K

    2008-03-15

    The present study was conducted to establish a simple and efficient method of producing monozygotic twin calves using the blastomere separation technique. To produce monozygotic twin embryos from zona-free two- and eight-cell embryos, blastomeres were separated mechanically by pipetting to form two demi-embryos; each single blastomere from the two-cell embryo and tetra-blastomeres from the eight-cell embryo were cultured in vitro using the Well of the Well culture system (WOW). This culture system supported the successful arrangement of blastomeres, resulting in their subsequent aggregation to form a demi-embryo developing to the blastocyst stage without a zona pellucida. There was no significant difference in the development to the blastocyst stage between blastomeres separated from eight-cell (72.0%) and two-cell (62.0%) embryos. The production rates of the monozygotic pair blastocysts and transferable paired blastocysts for demi-embryos obtained from eight-cell embryos (64.0 and 45.0%, respectively) were higher than those for demi-embryos obtained from two-cell embryos (49.0 and 31.0%, PWOW culture system, yielded viable monozygotic demi-embryos, resulting in high rates of pregnancy and twinning rates after embryo transfer.

  2. [The application of computer aided design and computer aided engineering technique in separation of Pygopagus conjoined twins].

    Zhang, Zhi-cheng; Sun, Tian-sheng; Li, Fang; Tang, Guo-lin

    2009-05-19

    To explore the effect of CAD and CAE related technique in separation of Pygopagus Conjoined Twins. CT images of Pygopagus conjoined twins were obtained and reconstructed in three-dimensional by Mimics software. 3D entity model of skin and spine of conjoined twins were made by fast plastic technique and equipment according to 3D data model. The circumference and area of fused and independent dural sac were measured by software of AutoCAD. The entity model is real reflection of skin and spine of Pygopagus. It was used in the procedures of discussion, sham operation, skin flap design and informed consent. In the measure of MRI, the circumference and area of fused dural sac was more than of independent dural sac, that is to say, the defect of dural sac can be repaired by direct suture. The intraoperative finding match with imaging measure results. The application of CAD and CAE in the procedure of preoperative plan have gave big help to successful separation of Pygopagus Conjoined Twins.

  3. Recent Administrative and Judicial Decisions Regarding Consideration of Source Separation in Determining BACT Under PSD

    This document may be of assistance in applying the New Source Review (NSR) air permitting regulations including the Prevention of Significant Deterioration (PSD) requirements. This document is part of the NSR Policy and Guidance Database. Some documents in the database are a scanned or retyped version of a paper photocopy of the original. Although we have taken considerable effort to quality assure the documents, some may contain typographical errors. Contact the office that issued the document if you need a copy of the original.

  4. Depth sensitivity and source-detector separations for near infrared spectroscopy based on the Colin27 brain template.

    Gary E Strangman

    Full Text Available Understanding the spatial and depth sensitivity of non-invasive near-infrared spectroscopy (NIRS measurements to brain tissue-i.e., near-infrared neuromonitoring (NIN - is essential for designing experiments as well as interpreting research findings. However, a thorough characterization of such sensitivity in realistic head models has remained unavailable. In this study, we conducted 3,555 Monte Carlo (MC simulations to densely cover the scalp of a well-characterized, adult male template brain (Colin27. We sought to evaluate: (i the spatial sensitivity profile of NIRS to brain tissue as a function of source-detector separation, (ii the NIRS sensitivity to brain tissue as a function of depth in this realistic and complex head model, and (iii the effect of NIRS instrument sensitivity on detecting brain activation. We found that increasing the source-detector (SD separation from 20 to 65 mm provides monotonic increases in sensitivity to brain tissue. For every 10 mm increase in SD separation (up to ~45 mm, sensitivity to gray matter increased an additional 4%. Our analyses also demonstrate that sensitivity in depth (S decreases exponentially, with a "rule-of-thumb" formula S=0.75*0.85(depth. Thus, while the depth sensitivity of NIRS is not strictly limited, NIN signals in adult humans are strongly biased towards the outermost 10-15 mm of intracranial space. These general results, along with the detailed quantitation of sensitivity estimates around the head, can provide detailed guidance for interpreting the likely sources of NIRS signals, as well as help NIRS investigators design and plan better NIRS experiments, head probes and instruments.

  5. Query-by-Example Music Information Retrieval by Score-Informed Source Separation and Remixing Technologies

    Goto Masataka

    2010-01-01

    Full Text Available We describe a novel query-by-example (QBE approach in music information retrieval that allows a user to customize query examples by directly modifying the volume of different instrument parts. The underlying hypothesis of this approach is that the musical mood of retrieved results changes in relation to the volume balance of different instruments. On the basis of this hypothesis, we aim to clarify the relationship between the change in the volume balance of a query and the genre of the retrieved pieces, called genre classification shift. Such an understanding would allow us to instruct users in how to generate alternative queries without finding other appropriate pieces. Our QBE system first separates all instrument parts from the audio signal of a piece with the help of its musical score, and then it allows users remix these parts to change the acoustic features that represent the musical mood of the piece. Experimental results showed that the genre classification shift was actually caused by the volume change in the vocal, guitar, and drum parts.

  6. Investigation of A = 152 radioactivities with mass-separated sources: Identification of /sup 152/Lu

    Toth, K.S.; Sousa, D.C.; Nitschke, J.M.; Wilmarth, P.A.

    1987-01-01

    Nuclides with A = 152 were produced in /sup 58/Ni bombardments of /sup 96/Ru and their decay properties were investigated following on-line mass separation. The isotope /sup 152/Lu (T/sub 1/2/ = 0.7 +- 0.1 s) was identified by γ rays in its β-decay daughter, /sup 152/Yb. Based on its decay characteristics, the parent state has a probable spin and parity assignment of (4,5,6 - ). Several new transitions were observed to follow the β decays of /sup 152/Yb and the /sup 152/Tm low-spin isomer; they established previously unknown levels in both /sup 152/Tm and /sup 152/Er. The additional γ rays in /sup 152/Yb decay reduce from 100% to 88% the direct feeding to the one excited state in /sup 152/Tm that had been known earlier. Nevertheless, the corresponding logft value is calculated to be 3.5, indicating that this is an allowed β transition which connects the 0 + parent with a 1 + excited state in /sup 152/Tm. By comparing the β-decay rates of /sup 148/Dy and /sup 152/Ho, and the α- and β-decay rates of /sup 152/Er, an α branch of 90 +- 4 % was deduced for /sup 152/Er

  7. Estimating representative background PM2.5 concentration in heavily polluted areas using baseline separation technique and chemical mass balance model

    Gao, Shuang; Yang, Wen; Zhang, Hui; Sun, Yanling; Mao, Jian; Ma, Zhenxing; Cong, Zhiyuan; Zhang, Xian; Tian, Shasha; Azzi, Merched; Chen, Li; Bai, Zhipeng

    2018-02-01

    The determination of background concentration of PM2.5 is important to understand the contribution of local emission sources to total PM2.5 concentration. The purpose of this study was to exam the performance of baseline separation techniques to estimate PM2.5 background concentration. Five separation methods, which included recursive digital filters (Lyne-Hollick, one-parameter algorithm, and Boughton two-parameter algorithm), sliding interval and smoothed minima, were applied to one-year PM2.5 time-series data in two heavily polluted cities, Tianjin and Jinan. To obtain the proper filter parameters and recession constants for the separation techniques, we conducted regression analysis at a background site during the emission reduction period enforced by the Government for the 2014 Asia-Pacific Economic Cooperation (APEC) meeting in Beijing. Background concentrations in Tianjin and Jinan were then estimated by applying the determined filter parameters and recession constants. The chemical mass balance (CMB) model was also applied to ascertain the effectiveness of the new approach. Our results showed that the contribution of background PM concentration to ambient pollution was at a comparable level to the contribution obtained from the previous study. The best performance was achieved using the Boughton two-parameter algorithm. The background concentrations were estimated at (27 ± 2) μg/m3 for the whole year, (34 ± 4) μg/m3 for the heating period (winter), (21 ± 2) μg/m3 for the non-heating period (summer), and (25 ± 2) μg/m3 for the sandstorm period in Tianjin. The corresponding values in Jinan were (30 ± 3) μg/m3, (40 ± 4) μg/m3, (24 ± 5) μg/m3, and (26 ± 2) μg/m3, respectively. The study revealed that these baseline separation techniques are valid for estimating levels of PM2.5 air pollution, and that our proposed method has great potential for estimating the background level of other air pollutants.

  8. Source-jerk analysis using a semi-explicit inverse kinetic technique

    Spriggs, G.D.; Pederson, R.A.

    1985-01-01

    A method is proposed for measuring the effective reproduction factor, k, in subcritical systems. The method uses the transient response of a subcritical system to the sudden removal of an extraneous neutron source (i.e., a source jerk). The response is analyzed using an inverse kinetic technique that least-squares fits the exact analytical solution corresponding to a source-jerk transient as derived from the point-reactor model. It has been found that the technique can provide an accurate means of measuring k in systems that are close to critical (i.e., 0.95 < k < 1.0). As a system becomes more subcritical (i.e., k << 1.0) spatial effects can introduce significant biases depending on the source and detector positions. However, methods are available that can correct for these biases and, hence, can allow measuring subcriticality in systems with k as low as 0.5. 12 refs., 3 figs

  9. Source-jerk analysis using a semi-explicit inverse kinetic technique

    Spriggs, G.D.; Pederson, R.A.

    1985-01-01

    A method is proposed for measuring the effective reproduction factor, k, in subcritical systems. The method uses the transient responses of a subcritical system to the sudden removal of an extraneous neutron source (i.e., a source jerk). The response is analyzed using an inverse kinetic technique that least-squares fits the exact analytical solution corresponding to a source-jerk transient as derived from the point-reactor model. It has been found that the technique can provide an accurate means of measuring k in systems that are close to critical (i.e., 0.95 < k < 1.0). As a system becomes more subcritical (i.e., k << 1.0) spatial effects can introduce significant biases depending on the source and detector positions. However, methods are available that can correct for these biases and, hence, can allow measuring subcriticality in systems with k as low as 0.5

  10. APPLICATION OF COMPENSATION METHOD FOR SEPARATION USEFUL SIGNAL AND INTERFERENCE FROM NEARBY SOURCES

    2016-01-01

    Full Text Available Based on the comparative analysis of the known methods of noise suppression the ratios for the angular measurements are obtained. A mathematical model experiment to estimate the dependence of measurement error on the relative position of interference source and useful signal has been conducted. The modified method of interfer- ence compensation is tested experimentally. The analysis of obtained angular measurements for the considered methods shows that the modified method of compensation allows obtaining more precise estimates. The analyzed methodsallow considerably eliminating the useful signal from the antenna additional channel which reduces errors of angular misalignment.To determine the degree of the radar error analytically is not always possible, and in future comparison of the ef- fectiveness of various methods of interference compensation will be expected to conduct by means of mathematical model-ing of radar closed contour.

  11. The separation of control variables in an H/sup /minus// ion source

    Bowling, P.S.; Brown, S.K.

    1988-01-01

    This paper describes a successful methodology which was used to classify a series if waveforms taken from a 100 ma H/sup /minus// ion source at Los Alamos. The series of 260 waveforms was divided into a ''training'' set and a ''test'' set. A sequence of mathematical transformations was performed on the ''training'' waveforms data and then it was subjected to discriminant analysis. The analysis generates a set of filters which will allow classification of an unknown waveform in the ''test'' set as being either stable or unstable; if stable, whether optimal or not; if not optimal, which of the six control parameters should be adjusted to bring it to an optimal condition. We have found that the probability of successful classification using this methodology is 91.5%. 3 refs., 4 figs., 2 tabs

  12. Advanced energy sources and conversion techniques. Proceedings of a seminar. Volume 1. [35 papers

    None

    1958-11-01

    The Seminar was organized as a series of tutorial presentations and round table discussions on a technical level to implement the following: (a) to identify and explore present and projected needs for energy sources and conversion techniques for military applications; (b) to exchange information on current and planned efforts in these fields; (c) to examine the effect of anticipated scientific and technological advances on these efforts; and (d) to present suggested programs aimed at satisfying the military needs for energy sources and conversion techniques. Volume I contains all of the unclassified papers presented at the Seminar. (W.D.M.)

  13. Chemical Separation Technique of Strontium-90 in the Soil Water as theStandard Methods for Environmental Radioactivity Analysis

    Ngasifudin-Hamdani; Suratman; Djoko-Sardjono, Ign; Winduanto-Wahyu SP

    2000-01-01

    Research about separation technique of strontium-90 from its materialmatrix using chemical precipitation method has been done. That technique wasapplied on the detection of radionuclide strontium-90 containing in the soilwater of near nuclear reactor facility P3TM BATAN in three location. The twoimportant parameters used in this technique were growth time of Y-90 andstirring time. The result shown that activity of strontium-90 in the pos-01was between 1.801x10 -19 - 9.616x10 -17 μCi/cm 3 , pos-02 was8.448x10 -19 - 1.003x X 10 -16 μCi/cm 3 and pos-03 was 6.719x10 -19 - 11.644x10 -16 μCi/cm 3 . From those data shown that activity of Sr-90in the soil water of near nuclear reactor facility P3TM BATAN was still belowthe limit value of maximum concentration permitted i.e. 4.0x10 -7 -3.5x10 -6 μCi/cm 3 . The statistic test using analysis of varian twofactorial with random block design shown that the activity of Sr-90 in thesoil water was influenced by the interaction which take place between growthlong time of Y-90 and stirring long time. (author)

  14. An alternative technique for simulating volumetric cylindrical sources in the Morse code utilization

    Vieira, W.J.; Mendonca, A.G.

    1985-01-01

    In the solution of deep-penetration problems using the Monte Carlo method, calculation techniques and strategies are used in order to increase the particle population in the regions of interest. A common procedure is the coupling of bidimensional calculations, with (r,z) discrete ordinates transformed into source data, and tridimensional Monte Carlo calculations. An alternative technique for this procedure is presented. This alternative proved effective when applied to a sample problem. (F.E.) [pt

  15. An investigation of the usability of sound recognition for source separation of packaging wastes in reverse vending machines.

    Korucu, M Kemal; Kaplan, Özgür; Büyük, Osman; Güllü, M Kemal

    2016-10-01

    In this study, we investigate the usability of sound recognition for source separation of packaging wastes in reverse vending machines (RVMs). For this purpose, an experimental setup equipped with a sound recording mechanism was prepared. Packaging waste sounds generated by three physical impacts such as free falling, pneumatic hitting and hydraulic crushing were separately recorded using two different microphones. To classify the waste types and sizes based on sound features of the wastes, a support vector machine (SVM) and a hidden Markov model (HMM) based sound classification systems were developed. In the basic experimental setup in which only free falling impact type was considered, SVM and HMM systems provided 100% classification accuracy for both microphones. In the expanded experimental setup which includes all three impact types, material type classification accuracies were 96.5% for dynamic microphone and 97.7% for condenser microphone. When both the material type and the size of the wastes were classified, the accuracy was 88.6% for the microphones. The modeling studies indicated that hydraulic crushing impact type recordings were very noisy for an effective sound recognition application. In the detailed analysis of the recognition errors, it was observed that most of the errors occurred in the hitting impact type. According to the experimental results, it can be said that the proposed novel approach for the separation of packaging wastes could provide a high classification performance for RVMs. Copyright © 2016 Elsevier Ltd. All rights reserved.

  16. Comparative Study of Modulation Techniques for Two-Level Voltage Source Inverters

    Barry W. Williams

    2016-06-01

    Full Text Available A detailed comparative study of modulation techniques for single and three phase dc-ac inverters is presented.  Sinusoidal Pulse Width Modulation, Triplen Sinusoidal Pulse Width Modulation, Space Vector Modulation, Selective Harmonic Elimination and Wavelet Modulation are assessed and compared in terms of maximum fundamental output, harmonic performance, switching losses and operational mode.  The presented modulation techniques are applied to single and three phase voltage source inverters and are simulated using SIMULINK.  The simulation results clarify the inverter performance achieved using the different modulations techniques.

  17. Emissions of Volatile Organic Compounds (VOCs) from Animal Husbandry: Chemical Compositions, Separation of Sources and Animal Types

    Yuan, B.; Coggon, M.; Koss, A.; Warneke, C.; Eilerman, S. J.; Neuman, J. A.; Peischl, J.; Aikin, K. C.; Ryerson, T. B.; De Gouw, J. A.

    2016-12-01

    Concentrated animal feeding operations (CAFOs) are important sources of volatile organic compounds (VOCs) in the atmosphere. We used a hydronium ion time-of-flight chemical ionization mass spectrometer (H3O+ ToF-CIMS) to measure VOC emissions from CAFOs in the Northern Front Range of Colorado during an aircraft campaign (SONGNEX) for regional contributions and from a mobile laboratory sampling for chemical characterizations of individual animal feedlots. The main VOCs emitted from CAFOs include carboxylic acids, alcohols, carbonyls, phenolic species, sulfur- and nitrogen-containing species. Alcohols and carboxylic acids dominate VOC concentrations. Sulfur-containing and phenolic species become more important in terms of odor activity values and NO3 reactivity, respectively. The high time-resolution mobile measurements allow the separation of the sources of VOCs from different parts of the operations occurring within the facilities. We show that the increase of ethanol concentrations were primarily associated with feed storage and handling. We apply a multivariate regression analysis using NH3 and ethanol as tracers to attribute the relative importance of animal-related emissions (animal exhalation and waste) and feed-related emissions (feed storage and handling) for different VOC species. Feed storage and handling contribute significantly to emissions of alcohols, carbonyls and carboxylic acids. Phenolic species and nitrogen-containing species are predominantly associated with animals and their waste. VOC ratios can be potentially used as indicators for the separation of emissions from dairy and beef cattle from the regional aircraft measurements.

  18. Separation and quantitation of radionuclides in Hanford environmental and waste tank samples using IC-ICP/MS techniques

    Farmer, O.T. III; Smith, M.R.; Wyse, E.J.; Barinage, C.J.; Koppenaal, D.W.

    1996-01-01

    The use of shielded ICP/MS instrumentation to characterize radioactive material has seen marked growth over the past few years. With a lower limit detection now in the fg/mL range for newer units, ICP/MS has become the method of choice for many studies requiring rapid, isotopic analysis of both stable elements and radionuclides with half-lives greater than 102-103 years. However, despite its sensitivity and versatility, ICP/MS has heretofore had some notable limitations in certain radiological applications. For example, Hanford waste tank samples contain a variety of nuclides with altered isotopic abundances, which complicate identification of these nuclides. Even if a nuclide can be identified, conventional quantitation using vendor-supplied software assumes natural, or knowledge of, isotopic abundance. Difficult sample matrices like those obtained from the Hanford tanks can further complicate interpretation and quantitation. On-line ion chromatography (IC) has been recently employed to mitigate some these problems. By sequentially separating elements, isobars can be resolved, thereby permitting the unequivocal determination of isotopic abundances. But even though the technique resolves isobaric interferences and is effective in reducing matrix problems, IC does not easily lend itself to quantitation. Internal standards, which are crucial for quantitation during a prolonged ICP/MS analysis with varying eluant matrices, are separated or affected as any indigenous element is using standard IC methodology

  19. Artificial lateral-line system for imaging dipole sources using Beamforming techniques

    Dagamseh, A.M.K.; Wiegerink, Remco J.; Lammerink, Theodorus S.J.; Krijnen, Gijsbertus J.M.

    In nature, fish have the ability to localize prey, school, navigate, etc. using the lateral-line organ [1]. Here we present the use of biomimetic artificial hair-based flow-sensors arranged as lateral-line system in combination with beamforming techniques for dipole source localization in air.

  20. Advanced techniques for high resolution spectroscopic observations of cosmic gamma-ray sources

    Matteson, J.L.; Pelling, M.R.; Peterson, L.E.

    1985-08-01

    We describe an advanced gamma-ray spectrometer that is currently in development. It will obtain a sensitivity of -4 ph/cm -2 -sec in a 6 hour balloon observation and uses innovative techniques for background reduction and source imaging

  1. Identifying sources of atmospheric fine particles in Havana City using Positive Matrix Factorization technique

    Pinnera, I.; Perez, G.; Ramos, M.; Guibert, R.; Aldape, F.; Flores M, J.; Martinez, M.; Molina, E.; Fernandez, A.

    2011-01-01

    In previous study a set of samples of fine and coarse airborne particulate matter collected in a urban area of Havana City were analyzed by Particle-Induced X-ray Emission (PIXE) technique. The concentrations of 14 elements (S, Cl, K, Ca, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, Br and Pb) were consistently determined in both particle sizes. The analytical database provided by PIXE was statistically analyzed in order to determine the local pollution sources. The Positive Matrix Factorization (PMF) technique was applied to fine particle data in order to identify possible pollution sources. These sources were further verified by enrichment factor (EF) calculation. A general discussion about these results is presented in this work. (Author)

  2. Nanopositioning techniques development for synchrotron radiation instrumentation applications at the Advanced Photon Source

    Shu Deming

    2010-01-01

    At modern synchrotron radiation sources and beamlines, high-precision positioning techniques present a significant opportunity to support state-of-the-art synchrotron radiation research. Meanwhile, the required instrument positioning performance and capabilities, such as resolution, dynamic range, repeatability, speed, and multiple axes synchronization are exceeding the limit of commercial availability. This paper presents the current nanopositioning techniques developed for the Argonne Center for Nanoscale Materials (CNM)/Advanced Photon Source (APS) hard x-ray nanoprobe and high-resolution x-ray monochromators and analyzers for the APS X-ray Operations and Research (XOR) beamlines. Future nanopositioning techniques to be developed for the APS renewal project will also be discussed.

  3. A technique for separation of canine lymphocytes and their use in the lymphocytotoxic, blastogenic, and rosette assys.

    Whitacre, C C; Lang, R W

    1975-01-01

    When the techniques established for preparing lymphocytes from human blood were applied to canine blood, the resulting preparations were contaminated with significant numbers of other blood cells. A three-step technique is described here for the separation of canine lymphocytes from blood which eliminates most granulocytes, platelets, and erythrocytes. Defibrinated blood is incubated with iron particles to allow phagocytosis by granulocytes. When mixed with Plasmagel, erythrocytes and iron-containing granulocytes sediment rapidly, leaving a lymphocyte-rich supernate plasma which is recovered and banded by centrifugation on a Ficoll-Hypaque gradient. Any erythrocytes remaining in the lymphocyte suspension aspirated from the gradient are eliminated by hypotonic lysis and centrifugation. The resulting preparation, representing 30 per cent recovery of the circulating lymphocytes, contained 85 to 94 per cent lymphocytes with a cell viability of 99 per cent. The functional capacity of the lymphocyte preparation was tested in three assays: 1) lymphoblastic transformation using phytohemagglutinin and pokeweed mitogen, 2) E rosette formation with human erythrocytes showed a mean 5 per cent rosette forming lymphocytes, 3) antibody-mediated lymphocytotoxicity using a canine anti-lymphocyte serum showed titers reproducible within one tube dilution.

  4. Ionic Liquid and Supercritical Fluid Hyphenated Techniques for Dissolution and Separation of Lanthanides, Actinides, and Fission Products

    Wai, Chien M.; Mincher, Bruce

    2012-01-01

    This project is investigating techniques involving ionic liquids (IL) and supercritical (SC) fluids for dissolution and separation of lanthanides, actinides, and fission products. The research project consists of the following tasks: Study direct dissolution of lanthanide oxides, uranium dioxide and other actinide oxides in [bmin][Tf 2 N] with TBP(HNO 3 ) 1.8 (H 2 O) 0.6 and similar types of Lewis acid-Lewis base complexing agents; Measure distributions of dissolved metal species between the IL and the sc-CO 2 phases under various temperature and pressure conditions; Investigate the chemistry of the dissolved metal species in both IL and sc-CO 2 phases using spectroscopic and chemical methods; Evaluate potential applications of the new extraction techniques for nuclear waste management and for other projects. Supercritical carbon dioxide (sc-CO 2 ) and ionic liquids are considered green solvents for chemical reactions and separations. Above the critical point, CO 2 has both gas- and liquid-like properties, making it capable of penetrating small pores of solids and dissolving organic compounds in the solid matrix. One application of sc-CO 2 extraction technology is nuclear waste management. Ionic liquids are low-melting salts composed of an organic cation and an anion of various forms, with unique properties making them attractive replacements for the volatile organic solvents traditionally used in liquid-liquid extraction processes. One type of room temperature ionic liquid (RTIL) based on the 1-alkyl-3-methylimidazolium cation [bmin] with bis(trifluoromethylsulfonyl)imide anion [Tf 2 N] is of particular interest for extraction of metal ions due to its water stability, relative low viscosity, high conductivity, and good electrochemical and thermal stability. Recent studies indicate that a coupled IL sc-CO 2 extraction system can effectively transfer trivalent lanthanide and uranyl ions from nitric acid solutions. Advantages of this technique include operation at

  5. Artificial intelligence search techniques for optimization of the cold source geometry

    Azmy, Y.Y.

    1988-01-01

    Most optimization studies of cold neutron sources have concentrated on the numerical prediction or experimental measurement of the cold moderator optimum thickness which produces the largest cold neutron leakage for a given thermal neutron source. Optimizing the geometrical shape of the cold source, however, is a more difficult problem because the optimized quantity, the cold neutron leakage, is an implicit function of the shape which is the unknown in such a study. We draw an analogy between this problem and a state space search, then we use a simple Artificial Intelligence (AI) search technique to determine the optimum cold source shape based on a two-group, r-z diffusion model. We implemented this AI design concept in the computer program AID which consists of two modules, a physical model module and a search module, which can be independently modified, improved, or made more sophisticated. 7 refs., 1 fig

  6. Artificial intelligence search techniques for the optimization of cold source geometry

    Azmy, Y.Y.

    1988-01-01

    Most optimization studies of cold neutron sources have concentrated on the numerical prediction or experimental measurement of the cold moderator optimum thickness that produces the largest cold neutron leakage for a given thermal neutron source. Optimizing the geometric shape of the cold source, however, is a more difficult problem because the optimized quantity, the cold neutron leakage, is an implicit function of the shape, which is the unknown in such a study. An analogy is drawn between this problem and a state space search, then a simple artificial intelligence (AI) search technique is used to determine the optimum cold source shape based on a two-group, r-z diffusion model. This AI design concept was implemented in the computer program AID, which consists of two modules, a physical model module, and a search module, which can be independently modified, improved, or made more sophisticated

  7. INAA in combination with other analytical techniques in the study of urban aerosol sources

    Binh, N.T.; Truong, Y.; Ngo, N.T.; Sieu, L.N.; Hien, P.D.

    2000-01-01

    Concentrations of elements in fine and coarse PM10 samples collected in Ho Chi Minh City were determined by INAA for the purpose of characterising air pollution sources using multivariate receptor modeling techniques. Seven sources common to coarse and fine samples were identified. Resuspended soil dust is dominant in the coarse samples accounting for 41% of the particulate mass. In the fine samples, vehicle emissions and coal burning are most important accounting for about 20% each. Although a great number of elements were included in the input data for receptor modeling, the interpretation of emission sources was not always straightforward. Information on other source markers were needed. Therefore, a polarography method was used for quantifying lead, and recently, ion chromatography method became available for quantifying secondary sulphates, nitrates and other water soluble ions. (author)

  8. Global warming potential of material fractions occurring in source-separated organic household waste treated by anaerobic digestion or incineration under different framework conditions

    Naroznova, Irina; Møller, Jacob; Scheutz, Charlotte

    2016-01-01

    This study compared the environmental profiles of anaerobic digestion (AD) and incineration, in relation to global warming potential (GWP), for treating individual material fractions that may occur in source-separated organic household waste (SSOHW). Different framework conditions representative...

  9. Techniques for Handling Channeling in High Resolution Fourier Transform Spectra Recorded with Synchrotron Sources

    Ibrahim, Amr; PredoiCross, Adriana; Teillet, P. M.

    2010-01-01

    Seven different techniques in dealing the problem of channel spectra in Fourier transform Spectroscopy utilizing synchrotron source were examined and compared. Five of these techniques deal with the artifacts (spikes) in the recorded interferogram which in turn result in channel spectra within the spectral domain. Such interferogram editing method include replacing these spikes with zeros, straight line, fitted polynomial curve, rescaled spike and spike reduced with Gauss Function. Another two techniques try to target this issue in the spectral domain instead by either generating a synthetic background simulating the channels or measuring the channels parameters (amplitude, spacing and phase) to use in the spectral fitting program. Results showed spectral domain techniques produces higher quality results in terms of signal to noise and fitting residual. The effect of each method on the line parameters such as position, intensity are air broadening are also measured and discussed.

  10. [Demand for and the Development of Detection Techniques for Source of Schistosome Infection in China].

    Wang, Shi-ping; He, Xin; Zhou, Yun-fei

    2015-12-01

    Schistosomiasis is a type of zoonotic parasitosis that severely impairs human health. Rapid detection of infection sources is a key to the control of schistosomiasis. With the effective control of schistosomiasis in China, the detection techniques for infection sources have also been developed. The rate and the intensity of infection among humans and livestocks have been significantly decreased in China, as the control program has entered the transmission control stage in most of the endemic areas. Under this situation, the traditional etiological diagnosing techniques and common immunological methods can not afford rapid detection of infection sources of schistosomiasis. Instead, we are calling for detection methods with higher sensitivity, specificity and stability while being less time-consuming, more convenient and less costing. In recent years, many improved or novel detection methods have been applied for the epidemiological surveillance of schistosomiasis, such as the automatic scanning microscopic image acquisition system, PCR-ELISA, immunosensors, loop-mediated isothermal amplification, etc. The development of new monitoring techniques can facilitate rapid detection of schistosome infection sources in endemic areas.

  11. A Comparison Study of Sinusoidal PWM and Space Vector PWM Techniques for Voltage Source Inverter

    Ömer Türksoy

    2017-06-01

    Full Text Available In this paper, the methods used to control voltage source inverters which have been intensively investigated in recent years are compared. Although the most efficient result is obtained with the least number of switching elements in the inverter topologies, the method used in the switching is at least as effective as the topology. Besides, the selected switching method to control the inverter will play an effective role in suppressing harmonic components while producing the ideal output voltage. There are many derivatives of pulse width modulation techniques that are commonly used to control voltage source inverters. Some of widespread methods are sinusoidal pulse width modulation and space vector pulse width modulation techniques. These modulation techniques used for generating variable frequency and amplitude output voltage in voltage source inverters, have been simulated by using MATLAB/SIMULINK. And, the total harmonic distortions of the output voltages are compared. As a result of simulation studies, sinusoidal pulse width modulation has been found to have more total harmonic distortion in output voltages of voltage source inverters in the simulation. Space vector pulse width modulation has been shown to produce a more efficient output voltage with less total harmonic distortion.

  12. Evaluation of a new pulping technology for pre-treating source-separated organic household waste prior to anaerobic digestion

    Naroznova, Irina; Møller, Jacob; Larsen, Bjarne

    2016-01-01

    A new technology for pre-treating source-separated organic household waste prior to anaerobic digestion was assessed, and its performance was compared to existing alternative pre-treatment technologies. This pre-treatment technology is based on waste pulping with water, using a specially developed...... screw mechanism. The pre-treatment technology rejects more than 95% (wet weight) of non-biodegradable impurities in waste collected from households and generates biopulp ready for anaerobic digestion. Overall, 84-99% of biodegradable material (on a dry weight basis) in the waste was recovered...... in the biopulp. The biochemical methane potential for the biopulp was 469±7mL CH4/g ash-free mass. Moreover, all Danish and European Union requirements regarding the content of hazardous substances in biomass intended for land application were fulfilled. Compared to other pre-treatment alternatives, the screw...

  13. Anaerobic treatment as a core technology for energy, nutrients and water recovery from source-separated domestic waste(water).

    Zeeman, Grietje; Kujawa, Katarzyna; de Mes, Titia; Hernandez, Lucia; de Graaff, Marthe; Abu-Ghunmi, Lina; Mels, Adriaan; Meulman, Brendo; Temmink, Hardy; Buisman, Cees; van Lier, Jules; Lettinga, Gatze

    2008-01-01

    Based on results of pilot scale research with source-separated black water (BW) and grey water (GW), a new sanitation concept is proposed. BW and GW are both treated in a UASB (-septic tank) for recovery of CH4 gas. Kitchen waste is added to the anaerobic BW treatment for doubling the biogas production. Post-treatment of the effluent is providing recovery of phosphorus and removal of remaining COD and nitrogen. The total energy saving of the new sanitation concept amounts to 200 MJ/year in comparison with conventional sanitation, moreover 0.14 kg P/p/year and 90 litres of potential reusable water are produced. (c) IWA Publishing 2008.

  14. Characterisation of the biochemical methane potential (BMP) of individual material fractions in Danish source-separated organic household waste

    Naroznova, Irina; Møller, Jacob; Scheutz, Charlotte

    2016-01-01

    This study is dedicated to characterising the chemical composition and biochemical methane potential (BMP) of individual material fractions in untreated Danish source-separated organic household waste (SSOHW). First, data on SSOHW in different countries, available in the literature, were evaluated...... and then, secondly, laboratory analyses for eight organic material fractions comprising Danish SSOHW were conducted. No data were found in the literature that fully covered the objectives of the present study. Based on laboratory analyses, all fractions were assigned according to their specific properties......) and material degradability (BMP from laboratory incubation tests divided by TBMP) were expressed. Moreover, the degradability of lignocellulose biofibres (the share of volatile lignocellulose biofibre solids degraded in laboratory incubation tests) was calculated. Finally, BMP for average SSOHW composition...

  15. Guide for the recovery of high grade waste paper from federal office buildings through at-source separation

    1978-01-01

    This guide is intended to serve as a manual for organizing and managing office waste paper recovery programs in Canadian federal buildings. Waste paper generated in such buildings is of particular interest for recycling as it is produced in sufficiently large amounts, and contains large amounts of high-grade waste paper which obtain good prices from paper mills. The key to successful recovery of such paper is separation, at the source of waste generation, from other less-valuable papers and non-paper materials. In recommending ways to do this, the manual covers assessment of the viability of a collection program in a particular building, estimating the quantities of waste generated, calculating storage space necessary, marketing the paper collected, using proper collection and storage containers, promoting employee awareness, and administering and monitoring the program. A sample cost-benefit analysis is given for a general office building with 1,000 employees. Includes glossary. 14 refs., 10 figs., 5 tabs.

  16. Removal of power line interference of space bearing vibration signal based on the morphological filter and blind source separation

    Dong, Shaojiang; Sun, Dihua; Xu, Xiangyang; Tang, Baoping

    2017-06-01

    Aiming at the problem that it is difficult to extract the feature information from the space bearing vibration signal because of different noise, for example the running trend information, high-frequency noise and especially the existence of lot of power line interference (50Hz) and its octave ingredients of the running space simulated equipment in the ground. This article proposed a combination method to eliminate them. Firstly, the EMD is used to remove the running trend item information of the signal, the running trend that affect the signal processing accuracy is eliminated. Then the morphological filter is used to eliminate high-frequency noise. Finally, the components and characteristics of the power line interference are researched, based on the characteristics of the interference, the revised blind source separation model is used to remove the power line interferences. Through analysis of simulation and practical application, results suggest that the proposed method can effectively eliminate those noise.

  17. Ion source techniques for high-speed processing of material surface by ion beams

    Ishikawa, Junzo

    1990-01-01

    The present paper discusses some key or candidate techniques for future ion source development and such ion sources developed by the author. Several types of microwave ion sources for producing low charge state ions have been developed in Japan. When a microwave plasma cathode developed by the author is adapted to a Kaufman type ion source, the electron emission currents are found to be 2.5 A for argon gas and 0.5-0.9 A for oxygen gas. An alternative ionization method for metal atoms is strongly required for high-speed processing of material surface by metal-ion beams. Detailed discussion is made of collisional ionization of vaporized atoms, and negative-ion production (secondary negative-ion emission by sputtering). An impregnated electrode type liquid-metal ion source developed by the author, which has a porous tip structure, is described. The negative-ion production efficiency is quite high. The report also presents a neutral and ionized alkaline-metal bombardment type heavy negative-ion source, which consists of a cesium plasma ion source, suppressor, target electrode, negative-ion extraction electrode, and einzel lens. (N.K.)

  18. Analysis of jet-airfoil interaction noise sources by using a microphone array technique

    Fleury, Vincent; Davy, Renaud

    2016-03-01

    The paper is concerned with the characterization of jet noise sources and jet-airfoil interaction sources by using microphone array data. The measurements were carried-out in the anechoic open test section wind tunnel of Onera, Cepra19. The microphone array technique relies on the convected, Lighthill's and Ffowcs-Williams and Hawkings' acoustic analogy equation. The cross-spectrum of the source term of the analogy equation is sought. It is defined as the optimal solution to a minimal error equation using the measured microphone cross-spectra as reference. This inverse problem is ill-posed yet. A penalty term based on a localization operator is therefore added to improve the recovery of jet noise sources. The analysis of isolated jet noise data in subsonic regime shows the contribution of the conventional mixing noise source in the low frequency range, as expected, and of uniformly distributed, uncorrelated noise sources in the jet flow at higher frequencies. In underexpanded supersonic regime, a shock-associated noise source is clearly identified, too. An additional source is detected in the vicinity of the nozzle exit both in supersonic and subsonic regimes. In the presence of the airfoil, the distribution of the noise sources is deeply modified. In particular, a strong noise source is localized on the flap. For high Strouhal numbers, higher than about 2 (based on the jet mixing velocity and diameter), a significant contribution from the shear-layer near the flap is observed, too. Indications of acoustic reflections on the airfoil are also discerned.

  19. Innovative separation and preconcentration technique of coagulating homogenous dispersive micro solid phase extraction exploiting graphene oxide nanosheets.

    Ghazaghi, Mehri; Mousavi, Hassan Zavvar; Rashidi, Ali Morad; Shirkhanloo, Hamid; Rahighi, Reza

    2016-01-01

    A uniquely novel, fast, and facile technique is introduced for the first time in which a scant amount of graphene oxide (GO), without modification, has been utilized in dispersive mode of solid phase extraction (SPE) for an efficient yet simple separation. The proposed method of coagulating homogenous dispersive micro solid phase extraction (CHD-µSPE) is based on coagulation of homogeneous GO solution with the aid of polyetheneimine (PEI). CHD-µSPE use full adsorption capacity of GO because in this method was used GO solution obtained from synthesis process without drying step and stacking nanosheets. In optimized condition, 30 µL GO solution (7 mg mL(-1)), obtained in synthesis process, was injected into 1.5 mL the sample solution followed by immediate injection of 53 µL PEI solution (1 mg mL(-1)). After inserting PEI, GO sheets aggregate and can be readily separated by centrifugation. PEI not only cause aggregation of GO, but also form three-dimensional network of GO with easy handling in following separation steps. Lead, cadmium, and chromium were selected as model analytes and the effecting parameters including the amount of GO, concentration of PEI, sample pH, extraction time, and type of desorption solvent were investigated and optimized. The results indicate that the proposed CHD-µSPE method can be successfully applied GO in dispersive mode of SPE without effecting on good capability adsorption of GO. The novel method was applied in determination of lead, cadmium, and chromium in water, human saliva, and urine samples by electrothermal atomic absorption spectrometry. The detection limits are as low as 0.035, 0.005, and 0.012 µg L(-1) for Pb, Cd, and Cr respectively. The intra-day precisions (RSDs) were lower than 3.8%. CHD-µSPE method showed a good linear ranges of 0.24-15.6, 0.015-0.95 and 0.039-2.33 µg L(-1) for Pb, Cd and Cr respectively. Method performance was investigated by determination of mentioned metal ions in river water, human urine and

  20. Thickness measurement for the different metals by using Cs-137 gamma source with gamma transmission technique

    Bueyuek, B.; Tugrul, B.

    2009-01-01

    The purpose of this study is an experimental analysis of thickness measurement for various metals with the gamma transmission technique using Cs-137 as the radioisotope source. Lead, steel, brass, and aluminum, which are frequently used metals in industry, were chosen for the experiments. As the radioisotope source Cs-137 was preferred for the study since it has long half-life, it is mono energetic, and it penetrates the metals that were studied. Experiments were observed in the constant experimental geometry. Calibration curves for the four metal samples were plotted using the obtained results. To test the plotted calibration curves, counts for determining thickness measurement were collected for each sample and the obtained relative count values were used in conjunction with the plotted calibration curves for each sample to determine its thickness. The thicknesses of the samples have been measured with a micrometer and the results were comparatively analyzed with the measurement results obtained by the gamma transmission technique. The results of the analyses revealed that the thickness measurement values obtained with the gamma transmission technique and the thickness measurement values obtained with the conventional technique significantly converge to each other and the difference between the two values is at an acceptable level. Therefore the reliability of thickness measurements with the gamma transmission technique and the resulting calibration curves have been demonstrated.

  1. Separation techniques for the clean-up of radioactive mixed waste for ICP-AES/ICP-MS analysis

    Swafford, A.M.; Keller, J.M.

    1993-01-01

    Two separation techniques were investigated for the clean-up of typical radioactive mixed waste samples requiring elemental analysis by Inductively Coupled Plasma-Atomic Emission Spectroscopy (ICP-AES) or Inductively Coupled Plasma-Mass Spectrometry (ICP-MS). These measurements frequently involve regulatory or compliance criteria which include the determination of elements on the EPA Target Analyte List (TAL). These samples usually consist of both an aqueous phase and a solid phase which is mostly an inorganic sludge. Frequently, samples taken from the waste tanks contain high levels of uranium and thorium which can cause spectral interferences in ICP-AES or ICP-MS analysis. The removal of these interferences is necessary to determine the presence of the EPA TAL elements in the sample. Two clean-up methods were studied on simulated aqueous waste samples containing the EPA TAL elements. The first method studied was a classical procedure based upon liquid-liquid extraction using tri-n- octylphosphine oxide (TOPO) dissolved in cyclohexane. The second method investigated was based on more recently developed techniques using extraction chromatography; specifically the use of a commercially available Eichrom TRU·Spec trademark column. Literature on these two methods indicates the efficient removal of uranium and thorium from properly prepared samples and provides considerable qualitative information on the extraction behavior of many other elements. However, there is a lack of quantitative data on the extraction behavior of elements on the EPA Target Analyte List. Experimental studies on these two methods consisted of determining whether any of the analytes were extracted by these methods and the recoveries obtained. Both methods produced similar results; the EPA target analytes were only slightly or not extracted. Advantages and disadvantages of each method were evaluated and found to be comparable

  2. Comparison between correlated sampling and the perturbation technique of MCNP5 for fixed-source problems

    He Tao; Su Bingjing

    2011-01-01

    Highlights: → The performance of the MCNP differential operator perturbation technique is compared with that of the MCNP correlated sampling method for three types of fixed-source problems. → In terms of precision, the MCNP perturbation technique outperforms correlated sampling for one type of problem but performs comparably with or even under-performs correlated sampling for the other two types of problems. → In terms of accuracy, the MCNP perturbation calculations may predict inaccurate results for some of the test problems. However, the accuracy can be improved if the midpoint correction technique is used. - Abstract: Correlated sampling and the differential operator perturbation technique are two methods that enable MCNP (Monte Carlo N-Particle) to simulate small response change between an original system and a perturbed system. In this work the performance of the MCNP differential operator perturbation technique is compared with that of the MCNP correlated sampling method for three types of fixed-source problems. In terms of precision of predicted response changes, the MCNP perturbation technique outperforms correlated sampling for the problem involving variation of nuclide concentrations in the same direction but performs comparably with or even underperforms correlated sampling for the other two types of problems that involve void or variation of nuclide concentrations in opposite directions. In terms of accuracy, the MCNP differential operator perturbation calculations may predict inaccurate results that deviate from the benchmarks well beyond their uncertainty ranges for some of the test problems. However, the accuracy of the MCNP differential operator perturbation can be improved if the midpoint correction technique is used.

  3. Method for assessing the probability of accumulated doses from an intermittent source using the convolution technique

    Coleman, J.H.

    1980-10-01

    A technique is discussed for computing the probability distribution of the accumulated dose received by an arbitrary receptor resulting from several single releases from an intermittent source. The probability density of the accumulated dose is the convolution of the probability densities of doses from the intermittent releases. Emissions are not assumed to be constant over the brief release period. The fast fourier transform is used in the calculation of the convolution

  4. Combination of novel coalescing oil water separator and electrocoagulation technique for treatment of petroleum compound contaminated groundwater.

    Oladzad, Sepideh; Fallah, Narges; Nasernejad, Bahram

    2017-07-01

    In the present study a combination of a novel coalescing oil water separator (COWS) and electrocoagulation (EC) technique was used for treatment of petroleum product contaminated groundwater. In the first phase, COWS was used as the primary treatment. Two different types of coalescing media and two levels of flow rates were examined in order to find the optimum conditions. The effluent of COWS was collected in optimum conditions and was treated using an EC process in the second phase of the research. In this phase, preliminary experiments were conducted in order to investigate the effect of EC reaction time and sedimentation time on chemical oxygen demand (COD) removal efficiency. Best conditions for EC reaction time and sedimentation time were obtained to be 5 min and 30 min, respectively. Response surface methodology was applied to evaluate the effect of initial pH, current density and aeration rate on settling velocity (V s ) and effluent COD. The optimum conditions, for achieving maximum values of V s as well as the values of effluent COD, in the range of results were obtained at conditions of 7, 34 mA·cm -2 and 1.5 L·min -1 for initial pH, current density and aeration rate, respectively.

  5. Innovative separation and preconcentration technique of coagulating homogenous dispersive micro solid phase extraction exploiting graphene oxide nanosheets

    Ghazaghi, Mehri [Department of Chemistry, College of Science, Semnan University, P.O. Box: 35131-19111, Semnan (Iran, Islamic Republic of); Mousavi, Hassan Zavvar, E-mail: hzmousavi@semnan.ac.ir [Department of Chemistry, College of Science, Semnan University, P.O. Box: 35131-19111, Semnan (Iran, Islamic Republic of); Rashidi, Ali Morad [Nanotechnology Research Center, Research Institute of Petroleum Industry (RIPI), West Entrance Blvd., Olympic Village, P.O. Box: 14857-33111, Tehran (Iran, Islamic Republic of); Shirkhanloo, Hamid [Occupational and Environmental Health Research Center (OEHRC), Iranian Petroleum Industry Health Research Institute (IPIHRI), Tehran (Iran, Islamic Republic of); Rahighi, Reza [Nanotechnology Research Center, Research Institute of Petroleum Industry (RIPI), West Entrance Blvd., Olympic Village, P.O. Box: 14857-33111, Tehran (Iran, Islamic Republic of); Department of Research and Development, Sharif Ultrahigh Nanotechnologists (SUN) Company, P.O. Box: 13488-96394, Tehran (Iran, Islamic Republic of)

    2016-01-01

    A uniquely novel, fast, and facile technique is introduced for the first time in which a scant amount of graphene oxide (GO), without modification, has been utilized in dispersive mode of solid phase extraction (SPE) for an efficient yet simple separation. The proposed method of coagulating homogenous dispersive micro solid phase extraction (CHD-µSPE) is based on coagulation of homogeneous GO solution with the aid of polyetheneimine (PEI). CHD-µSPE use full adsorption capacity of GO because in this method was used GO solution obtained from synthesis process without drying step and stacking nanosheets. In optimized condition, 30 µL GO solution (7 mg mL{sup −1}), obtained in synthesis process, was injected into 1.5 mL the sample solution followed by immediate injection of 53 µL PEI solution (1 mg mL{sup −1}). After inserting PEI, GO sheets aggregate and can be readily separated by centrifugation. PEI not only cause aggregation of GO, but also form three-dimensional network of GO with easy handling in following separation steps. Lead, cadmium, and chromium were selected as model analytes and the effecting parameters including the amount of GO, concentration of PEI, sample pH, extraction time, and type of desorption solvent were investigated and optimized. The results indicate that the proposed CHD-µSPE method can be successfully applied GO in dispersive mode of SPE without effecting on good capability adsorption of GO. The novel method was applied in determination of lead, cadmium, and chromium in water, human saliva, and urine samples by electrothermal atomic absorption spectrometry. The detection limits are as low as 0.035, 0.005, and 0.012 µg L{sup −1} for Pb, Cd, and Cr respectively. The intra-day precisions (RSDs) were lower than 3.8%. CHD-µSPE method showed a good linear ranges of 0.24–15.6, 0.015–0.95 and 0.039–2.33 µg L{sup −1} for Pb, Cd and Cr respectively. Method performance was investigated by determination of mentioned

  6. Application of source biasing technique for energy efficient DECODER circuit design: memory array application

    Gupta, Neha; Parihar, Priyanka; Neema, Vaibhav

    2018-04-01

    Researchers have proposed many circuit techniques to reduce leakage power dissipation in memory cells. If we want to reduce the overall power in the memory system, we have to work on the input circuitry of memory architecture i.e. row and column decoder. In this research work, low leakage power with a high speed row and column decoder for memory array application is designed and four new techniques are proposed. In this work, the comparison of cluster DECODER, body bias DECODER, source bias DECODER, and source coupling DECODER are designed and analyzed for memory array application. Simulation is performed for the comparative analysis of different DECODER design parameters at 180 nm GPDK technology file using the CADENCE tool. Simulation results show that the proposed source bias DECODER circuit technique decreases the leakage current by 99.92% and static energy by 99.92% at a supply voltage of 1.2 V. The proposed circuit also improves dynamic power dissipation by 5.69%, dynamic PDP/EDP 65.03% and delay 57.25% at 1.2 V supply voltage.

  7. Speciation of trace elements in biological samples by nuclear analytical and related techniques coupled with chemical and biochemical separation

    Chen, C.Y.; Gao, Y.X.; Li, B.; Yu, H.W.; Li, Y.F.; Sun, J.; Chai, Z.F.

    2005-01-01

    In the past, most analytical problems relating to biological systems were addressed by measuring the total concentrations of elements. Now there is increasing interest of the importance of their chemical forms, in which an element is present in biological systems, e.g., the oxidation state, the binding state with macromolecules, or even the molecular structure. The biological effects of chromium, which is classified as an essential nutrient, are dependent upon its oxidation. state. In general, trivalent chromium is biochemically active, whereas hexavalent chromium is considered to be toxic. Mercury is one of serious environmental persistent pollutants. However, organic forms of mercury are known to possess much higher toxicity than inorganic mercury. Therefore, information on speciation is critically required in order to better understanding of their bioavailability, metabolism, transformation, and toxicity in vivo. Recently, chemical speciation of selenium, mercury, copper, zinc, iron, and so on, has been investigated by INAA, ICP-MS, XRF, EXAFS and related techniques combined with chemical and biochemical separation (extraction, chromatography, gel electrophoresis, etc.). INAA, XRF, and ICP-MS have superior advantages in aspect of multielemental analysis with high accuracy and sensitivity, which render the possibility of analyzing various elements of interest simultaneously. These offline or online techniques have been flexibly applied to different biological matrixes, such as human hair, serum, urine, various tissues and organs in our researches. In addition, EXAFS provides structural information about the moiety of metal centers up to a distance of approximately 4-5 Anstrom. For instance, hepatocellular carcinoma (HCC) is one of the most common cancers worldwide. Imbalance of elements, such as Se, Zn, Fe, Cu, Cd, Ca, etc., has been found in the whole blood or serum of patients with HCC. We found that the profiles of Se, Cd, Fe, Zn and Cu-containing proteins

  8. Automation of radiochemical analysis by flow injection techniques. Am-Pu separation using TRU-resinTM sorbent extraction column

    Egorov, O.; Washington Univ., Seattle, WA; Grate, J.W.; Ruzicka, J.

    1998-01-01

    A rapid automated flow injection analysis (FIA) procedure was developed for efficient separation of Am and Pu from each other and from interfering matrix and radionuclide components using a TRU-resin TM column. Selective Pu elution is enabled via on-column reduction. The separation was developed using on-line radioactivity detection. After the separation had been developed, fraction collection was used to obtain the separated fractions. In this manner, a FIA instrument functions as an automated separation workstation capable of unattended operation. (author)

  9. Apportionment of urban aerosol sources in Cork (Ireland) by synergistic measurement techniques.

    Dall'Osto, Manuel; Hellebust, Stig; Healy, Robert M; O'Connor, Ian P; Kourtchev, Ivan; Sodeau, John R; Ovadnevaite, Jurgita; Ceburnis, Darius; O'Dowd, Colin D; Wenger, John C

    2014-09-15

    The sources of ambient fine particulate matter (PM2.5) during wintertime at a background urban location in Cork city (Ireland) have been determined. Aerosol chemical analyses were performed by multiple techniques including on-line high resolution aerosol time-of-flight mass spectrometry (Aerodyne HR-ToF-AMS), on-line single particle aerosol time-of-flight mass spectrometry (TSI ATOFMS), on-line elemental carbon-organic carbon analysis (Sunset_EC-OC), and off-line gas chromatography/mass spectrometry and ion chromatography analysis of filter samples collected at 6-h resolution. Positive matrix factorization (PMF) has been carried out to better elucidate aerosol sources not clearly identified when analyzing results from individual aerosol techniques on their own. Two datasets have been considered: on-line measurements averaged over 2-h periods, and both on-line and off-line measurements averaged over 6-h periods. Five aerosol sources were identified by PMF in both datasets, with excellent agreement between the two solutions: (1) regional domestic solid fuel burning--"DSF_Regional," 24-27%; (2) local urban domestic solid fuel burning--"DSF_Urban," 22-23%; (3) road vehicle emissions--"Traffic," 15-20%; (4) secondary aerosols from regional anthropogenic sources--"SA_Regional" 9-13%; and (5) secondary aged/processed aerosols related to urban anthropogenic sources--"SA_Urban," 21-26%. The results indicate that, despite regulations for restricting the use of smoky fuels, solid fuel burning is the major source (46-50%) of PM2.5 in wintertime in Cork, and also likely other areas of Ireland. Whilst wood combustion is strongly associated with OC and EC, it was found that peat and coal combustion is linked mainly with OC and the aerosol from these latter sources appears to be more volatile than that produced by wood combustion. Ship emissions from the nearby port were found to be mixed with the SA_Regional factor. The PMF analysis allowed us to link the AMS cooking organic

  10. A new nonlinear blind source separation method with chaos indicators for decoupling diagnosis of hybrid failures: A marine propulsion gearbox case with a large speed variation

    Li, Zhixiong; Peng, Z

    2016-01-01

    The normal operation of propulsion gearboxes ensures the ship safety. Chaos indicators could efficiently indicate the state change of the gearboxes. However, accurate detection of gearbox hybrid faults using Chaos indicators is a challenging task and the detection under speed variation conditions is attracting considerable attentions. Literature review suggests that the gearbox vibration is a kind of nonlinear mixture of variant vibration sources and the blind source separation (BSS) is reported to be a promising technique for fault vibration analysis, but very limited work has addressed the nonlinear BSS approach for hybrid faults decoupling diagnosis. Aiming to enhance the fault detection performance of Chaos indicators, this work presents a new nonlinear BSS algorithm for gearbox hybrid faults detection under a speed variation condition. This new method appropriately introduces the kernel spectral regression (KSR) framework into the morphological component analysis (MCA). The original vibration data are projected into the reproducing kernel Hilbert space (RKHS) where the instinct nonlinear structure in the original data can be linearized by KSR. Thus the MCA is able to deal with nonlinear BSS in the KSR space. Reliable hybrid faults decoupling is then achieved by this new nonlinear MCA (NMCA). Subsequently, by calculating the Chaos indicators of the decoupled fault components and comparing them with benchmarks, the hybrid faults can be precisely identified. Two specially designed case studies were implemented to evaluate the proposed NMCA-Chaos method on hybrid gear faults decoupling diagnosis. The performance of the NMCA-Chaos was compared with state of art techniques. The analysis results show high performance of the proposed method on hybrid faults detection in a marine propulsion gearbox with large speed variations.

  11. Isotope separation

    Eerkens, J.W.

    1979-01-01

    A method of isotope separation is described which involves the use of a laser photon beam to selectively induce energy level transitions of an isotope molecule containing the isotope to be separated. The use of the technique for 235 U enrichment is demonstrated. (UK)

  12. Direct electrochemical oxidation of ammonia on graphite as a treatment option for stored source-separated urine.

    Zöllig, Hanspeter; Fritzsche, Cristina; Morgenroth, Eberhard; Udert, Kai M

    2015-02-01

    Electrolysis can be a viable technology for ammonia removal from source-separated urine. Compared to biological nitrogen removal, electrolysis is more robust and is highly amenable to automation, which makes it especially attractive for on-site reactors. In electrolytic wastewater treatment, ammonia is usually removed by indirect oxidation through active chlorine which is produced in-situ at elevated anode potentials. However, the evolution of chlorine can lead to the formation of chlorate, perchlorate, chlorinated organic by-products and chloramines that are toxic. This study focuses on using direct ammonia oxidation on graphite at low anode potentials in order to overcome the formation of toxic by-products. With the aid of cyclic voltammetry, we demonstrated that graphite is active for direct ammonia oxidation without concomitant chlorine formation if the anode potential is between 1.1 and 1.6 V vs. SHE (standard hydrogen electrode). A comparison of potentiostatic bulk electrolysis experiments in synthetic stored urine with and without chloride confirmed that ammonia was removed exclusively by continuous direct oxidation. Direct oxidation required high pH values (pH > 9) because free ammonia was the actual reactant. In real stored urine (pH = 9.0), an ammonia removal rate of 2.9 ± 0.3 gN·m(-2)·d(-1) was achieved and the specific energy demand was 42 Wh·gN(-1) at an anode potential of 1.31 V vs. SHE. The measurements of chlorate and perchlorate as well as selected chlorinated organic by-products confirmed that no chlorinated by-products were formed in real urine. Electrode corrosion through graphite exfoliation was prevented and the surface was not poisoned by intermediate oxidation products. We conclude that direct ammonia oxidation on graphite electrodes is a treatment option for source-separated urine with three major advantages: The formation of chlorinated by-products is prevented, less energy is consumed than in indirect ammonia oxidation and

  13. Semi-automated technique for the separation and determination of barium and strontium in surface waters by ion exchange chromatography and atomic emission spectrometry

    Pierce, F.D.; Brown, H.R.

    1977-01-01

    A semi-automated method for the separation and the analysis of barium and strontium in surface waters by atomic emission spectrometry is described. The method employs a semi-automated separation technique using ion exchange and an automated aspiration-analysis procedure. Forty specimens can be prepared in approximately 90 min and can be analyzed for barium and strontium content in 20 min. The detection limits and sensitivities provided by the described technique are 0.003 mg/l and 0.01 mg/l respectively for barium and 0.00045 mg/l and 0.003 mg/l respectively for strontium

  14. Efficacy of Blood Sources and Artificial Blood Feeding Methods in Rearing of Aedes aegypti (Diptera: Culicidae) for Sterile Insect Technique and Incompatible Insect Technique Approaches in Sri Lanka

    Nayana Gunathilaka; Tharaka Ranathunge; Lahiru Udayanga; Wimaladharma Abeyewickreme

    2017-01-01

    Introduction Selection of the artificial membrane feeding technique and blood meal source has been recognized as key considerations in mass rearing of vectors. Methodology Artificial membrane feeding techniques, namely, glass plate, metal plate, and Hemotek membrane feeding method, and three blood sources (human, cattle, and chicken) were evaluated based on feeding rates, fecundity, and hatching rates of Aedes aegypti. Significance in the variations among blood feeding was investigated by one...

  15. Spatial assessment and source identification of heavy metals pollution in surface water using several chemometric techniques.

    Ismail, Azimah; Toriman, Mohd Ekhwan; Juahir, Hafizan; Zain, Sharifuddin Md; Habir, Nur Liyana Abdul; Retnam, Ananthy; Kamaruddin, Mohd Khairul Amri; Umar, Roslan; Azid, Azman

    2016-05-15

    This study presents the determination of the spatial variation and source identification of heavy metal pollution in surface water along the Straits of Malacca using several chemometric techniques. Clustering and discrimination of heavy metal compounds in surface water into two groups (northern and southern regions) are observed according to level of concentrations via the application of chemometric techniques. Principal component analysis (PCA) demonstrates that Cu and Cr dominate the source apportionment in northern region with a total variance of 57.62% and is identified with mining and shipping activities. These are the major contamination contributors in the Straits. Land-based pollution originating from vehicular emission with a total variance of 59.43% is attributed to the high level of Pb concentration in the southern region. The results revealed that one state representing each cluster (northern and southern regions) is significant as the main location for investigating heavy metal concentration in the Straits of Malacca which would save monitoring cost and time. The monitoring of spatial variation and source of heavy metals pollution at the northern and southern regions of the Straits of Malacca, Malaysia, using chemometric analysis. Copyright © 2015 Elsevier Ltd. All rights reserved.

  16. Digital Control Techniques Based on Voltage Source Inverters in Renewable Energy Applications: A Review

    Sohaib Tahir

    2018-02-01

    Full Text Available In the modern era, distributed generation is considered as an alternative source for power generation. Especially, need of the time is to provide the three-phase loads with smooth sinusoidal voltages having fixed frequency and amplitude. A common solution is the integration of power electronics converters in the systems for connecting distributed generation systems to the stand-alone loads. Thus, the presence of suitable control techniques, in the power electronic converters, for robust stability, abrupt response, optimal tracking ability and error eradication are inevitable. A comprehensive review based on design, analysis, validation of the most suitable digital control techniques and the options available for the researchers for improving the power quality is presented in this paper with their pros and cons. Comparisons based on the cost, schemes, performance, modulation techniques and coordinates system are also presented. Finally, the paper describes the performance evaluation of the control schemes on a voltage source inverter (VSI and proposes the different aspects to be considered for selecting a power electronics inverter topology, reference frames, filters, as well as control strategy.

  17. Laser Scanning Systems and Techniques in Rockfall Source Identification and Risk Assessment: A Critical Review

    Fanos, Ali Mutar; Pradhan, Biswajeet

    2018-04-01

    Rockfall poses risk to people, their properties and to transportation ways in mountainous and hilly regions. This catastrophe shows various characteristics such as vast distribution, sudden occurrence, variable magnitude, strong fatalness and randomicity. Therefore, prediction of rockfall phenomenon both spatially and temporally is a challenging task. Digital Terrain model (DTM) is one of the most significant elements in rockfall source identification and risk assessment. Light detection and ranging (LiDAR) is the most advanced effective technique to derive high-resolution and accurate DTM. This paper presents a critical overview of rockfall phenomenon (definition, triggering factors, motion modes and modeling) and LiDAR technique in terms of data pre-processing, DTM generation and the factors that can be obtained from this technique for rockfall source identification and risk assessment. It also reviews the existing methods that are utilized for the evaluation of the rockfall trajectories and their characteristics (frequency, velocity, bouncing height and kinetic energy), probability, susceptibility, hazard and risk. Detail consideration is given on quantitative methodologies in addition to the qualitative ones. Various methods are demonstrated with respect to their application scales (local and regional). Additionally, attention is given to the latest improvement, particularly including the consideration of the intensity of the phenomena and the magnitude of the events at chosen sites.

  18. Source investigation of the tar balls deposited along the Gujarat coast, India, using chemical fingerprinting and transport modeling techniques

    Suneel, V.; Vethamony, P.; Naik, B.G.; VinodKumar, K.; Sreenu, L.; Samiksha, S.V.; Tai,Y.; Sudheesh, K.

    –1339. 14    (6). Brandli, M., Bucheli, T.D., Kupper, T., Mayer, J., Stadelman, F.X., Taradellas, J. Fate of PCBs, PAHs and their source characteristic ratios during composting and digestion of source-separated organic waste in full-scale plants. Environ...

  19. Life cycle and economic assessment of source-separated MSW collection with regard to greenhouse gas emissions: a case study in China.

    Dong, Jun; Ni, Mingjiang; Chi, Yong; Zou, Daoan; Fu, Chao

    2013-08-01

    In China, the continuously increasing amount of municipal solid waste (MSW) has resulted in an urgent need for changing the current municipal solid waste management (MSWM) system based on mixed collection. A pilot program focusing on source-separated MSW collection was thus launched (2010) in Hangzhou, China, to lessen the related environmental loads. And greenhouse gas (GHG) emissions (Kyoto Protocol) are singled out in particular. This paper uses life cycle assessment modeling to evaluate the potential environmental improvement with regard to GHG emissions. The pre-existing MSWM system is assessed as baseline, while the source separation scenario is compared internally. Results show that 23 % GHG emissions can be decreased by source-separated collection compared with the base scenario. In addition, the use of composting and anaerobic digestion (AD) is suggested for further optimizing the management of food waste. 260.79, 82.21, and -86.21 thousand tonnes of GHG emissions are emitted from food waste landfill, composting, and AD, respectively, proving the emission reduction potential brought by advanced food waste treatment technologies. Realizing the fact, a modified MSWM system is proposed by taking AD as food waste substitution option, with additional 44 % GHG emissions saved than current source separation scenario. Moreover, a preliminary economic assessment is implemented. It is demonstrated that both source separation scenarios have a good cost reduction potential than mixed collection, with the proposed new system the most cost-effective one.

  20. Isomer separation of $^{70g}Cu$ and $^{70m}Cu$ with a resonance ionization laser ion source

    Köster, U; Mishin, V I; Weissman, L; Huyse, M; Kruglov, K; Müller, W F; Van Duppen, P; Van Roosbroeck, J; Thirolf, P G; Thomas, H C; Weisshaar, D W; Schulze, W; Borcea, R; La Commara, M; Schatz, H; Schmidt, K; Röttger, S; Huber, G; Sebastian, V; Kratz, K L; Catherall, R; Georg, U; Lettry, Jacques; Oinonen, M; Ravn, H L; Simon, H

    2000-01-01

    Radioactive copper isotopes were ionized with the resonance ionization laser ion source at the on-line isotope separator ISOLDE (CERN). Using the different hyperfine structure in the 3d/sup 10/ 4s /sup 2/S/sub 1/2/-3d/sup 10/ 4p /sup 2/P/sub 1/2//sup 0/ transition the low- and high-spin isomers of /sup 70/Cu were selectively enhanced by tuning the laser wavelength. The light was provided by a narrow-bandwidth dye laser pumped by copper vapor lasers and frequency doubled in a BBO crystal. The ground state to isomeric state intensity ratio could be varied by a factor of 30, allowing to assign gamma transitions unambiguously to the decay of the individual isomers. It is shown that the method can also be used to determine magnetic moments. In a first experiment for the 1/sup +/ ground state of /sup 70/Cu a magnetic moment of (+)1.8(3) mu /sub N/ and for the high-spin isomer of /sup 70/Cu a magnetic moment of (+or-)1.2(3) mu /sub N/ could be deduced. (20 refs).

  1. Determining the Source of Water Vapor in a Cerium Oxide Electrochemical Oxygen Separator to Achieve Aviator Grade Oxygen

    Graf, John; Taylor, Dale; Martinez, James

    2014-01-01

    ]. Combined with a mechanical compressor, a Solid Electrolyte Oxygen Separator (SEOS) should be capable of producing ABO grade oxygen at pressures >2400 psia, on the space station. Feasibility tests using a SEOS integrated with a mechanical compressor identified an unexpected contaminant in the oxygen: water vapour was found in the oxygen product, sometimes at concentrations higher than 40 ppm (the ABO limit for water vapour is 7 ppm). If solid electrolyte membranes are really "infinitely selective" to oxygen as they are reported to be, where did the water come from? If water is getting into the oxygen, what other contaminants might get into the oxygen? Microscopic analyses of wafers, welds, and oxygen delivery tubes were performed in an attempt to find the source of the water vapour contamination. Hot and cold pressure decay tests were performed. Measurements of water vapour as a function of O2 delivery rate, O2 delivery pressure, and process air humidity levels were the most instructive in finding the source of water contamination (Fig 3). Water contamination was directly affected by oxygen delivery rate (doubling the oxygen production rate cut the water level in half). Water was affected by process air humidity levels and delivery pressure in a way that indicates the water was diffusing into the oxygen delivery system.

  2. A SOUND SOURCE LOCALIZATION TECHNIQUE TO SUPPORT SEARCH AND RESCUE IN LOUD NOISE ENVIRONMENTS

    Yoshinaga, Hiroshi; Mizutani, Koichi; Wakatsuki, Naoto

    At some sites of earthquakes and other disasters, rescuers search for people buried under rubble by listening for the sounds which they make. Thus developing a technique to localize sound sources amidst loud noise will support such search and rescue operations. In this paper, we discuss an experiment performed to test an array signal processing technique which searches for unperceivable sound in loud noise environments. Two speakers simultaneously played a noise of a generator and a voice decreased by 20 dB (= 1/100 of power) from the generator noise at an outdoor space where cicadas were making noise. The sound signal was received by a horizontally set linear microphone array 1.05 m in length and consisting of 15 microphones. The direction and the distance of the voice were computed and the sound of the voice was extracted and played back as an audible sound by array signal processing.

  3. Operational techniques employed for the liquid sodium source term control loops

    Chulos, L.E.

    1976-01-01

    Four Source Term Control Loops (STCLs) have been designed, constructed, and placed into operation at the Hanford Engineering Development Laboratory (HEDL) as part of the Radioactivity Control Technology program. The data obtained are used to determine the corrosion and deposition of LMFBR materials, including corrosion product radionuclides, in a non-isothermal flowing sodium system. The paper discusses operation of the STCL Facilities and, in particular, the methods used for controlling the oxygen content of the liquid sodium. These methods include cold trapping techniques, hot trapping, seeding the cold traps with sodium oxide, and precipitating the oxygen in the cold trap in a controlled manner. Operational problems encountered with the STCL Facilities and the techniques for correcting these problems are also discussed

  4. Detection and monitoring of pollutant sources with Lidar/Dial techniques

    Gaudio, P; Gelfusa, M; Malizia, A; Parracino, S; Richetta, M; De Leo, L; Perrimezzi, C; Bellecci, C

    2015-01-01

    It's well known that air pollution due to anthropogenic sources can have adverse effects on humans and the ecosystem. Therefore, in the last years, surveying large regions of the atmosphere in an automatic way has become a strategic objective of various public health organizations for early detection of pollutant sources in urban and industrial areas.The Lidar and Dial techniques have become well established laser based methods for the remote sensing of the atmosphere. They are often implemented to probe almost any level of the atmosphere and to acquire information to validate theoretical models about different topics of atmospheric physics. They can also be used for environment surveying by monitoring particles, aerosols and molecules.The aim of the present work is to demonstrate the potential of these methods to detect pollutants emitted from local sources (such as particulate and/or chemical compounds) and to evaluate their concentration. This is exemplified with the help of experimental data acquired in an industrial area in the south of Italy by mean of experimental campaign by use of pollutants simulated source. For this purpose, two mobile systems Lidar and Dial have been developed by the authors. In this paper there will be presented the operating principles of the system and the results of the experimental campaign. (paper)

  5. Scintillating confusion: Evaluation of a technique for measuring compact structure in weak radio sources

    Spangler, S.R.; Cordes, J.M.; Meyers, K.A.

    1979-01-01

    An attractive scheme for investigating compact structure in weak radio sources is to study the scintillation properties of confusion in a large single-dish radio telescope. We have investigated the utility of this technique by observing the scintillations of 860-MHz confusion of the NRAO 300' (91 m) telescope. Analysis of these data indicated a reduction in the mean scintillation index with decreasing flux density which implied that weaker sources possessed less compact structure. More direct observations indicated that the weak sources of interest were not significantly deficient in compact structure, so the first result is probably due to properties of the IPS process in the strong scintillation regime. Our results may be due to overresolution (by the IPS process in the strong scintillation regime) of the ''hot spots'' responsible for scintillation in most strong sources at frequencies below 1000 MHz, or may indicate abnormally strong turbulence in the solar wind during August, 1977. Future applications of this method would be best conducted at lower frequencies with larger reflectors or short-spacing interferometers

  6. STATE OF THE ART TECHNIQUES USED FOR NOISE SOURCE IDENTIFICATION ON COMPLEX BODIES

    Corneliu STOICA

    2010-03-01

    Full Text Available Over the last few decades, many approaches have been undertaken in order to asses detailed noise source identification on complex bodies, i.e. aircrafts, cars, machinery. Noise source identification implies to accurately obtain the position and frequency of the dominant noise sources. There are cases where traditional testing methods can not be applied at all or their use involves some limitations. Optical systems used for near field analysis require a line of sight that may not be available. The state-of-the-art technology for this purpose is the use of a large number of microphones whose signals are acquired simultaneously, i.e. microphone phased array. Due to the excessive cost of the instruments and the data acquisition system required, the implementation of this technology was restricted to governmental agencies (NASA, DLR and big companies such as Boeing and Airbus. During the past years, this technique was developed in wind tunnels and some universities to perform noise source identification on scale airframes, main landing gear models, and aerodynamic profiles (used on airplanes, helicopter rotors and wind mills.

  7. Electron-volt spectroscopy at a pulsed neutron source using a resonance detector technique

    Andreani, C; Senesi, R; Gorini, G; Tardocchi, M; Bracco, A; Rhodes, N; Schooneveld, E M

    2002-01-01

    The effectiveness of the neutron resonance detector spectrometer for deep inelastic neutron scattering measurements has been assessed by measuring the Pb scattering on the eVS spectrometer at ISIS pulsed neutron source and natural U foils as (n,gamma) resonance converters. A conventional NaI scintillator with massive shielding has been used as gamma detector. A neutron energy window up to 90 eV, including four distinct resonance peaks, has been assessed. A net decrease of the intrinsic width of the 6.6 eV resonance peak has also been demonstrated employing the double difference spectrum technique, with two uranium foils of different thickness.

  8. Silver ion chromatography for peak resolution enhancement: Application to the preparative separation of two sesquiterpenes using online heart-cutting LC-LC technique.

    Yang, Yang; Zhang, Yongmin; Wei, Chong; Li, Jing; Sun, Wenji

    2018-09-01

    Silver ion chromatography, utilizing columns packed with silver ions bonded to silica gel, has proved to be an invaluable technique for the analysis of some positional isomers. In this work, silver ion chromatography by combination with online heart-cutting LC-LC technique for the preparative separation of two sesquiterpenes positional isomers from a natural product was investigated. On the basis of the evaluation that silver ion content impacts on the separation, the laboratory-made silver ion columns, utilizing silica gel impregnated with 15% silver nitrate as column packing materials, were used for peak resolution improvement of these two isomers and the preparative separation of them in heart-cutting LC-LC. The relationship among the maximal sample load, flow rate and peak resolution in the silver ion column were optimized, and the performance of the silver ion column was compared with conventional C 18 column and silica gel column. Based on the developed chromatographic conditions, online heart-cutting LC-LC chromatographic separation system in combination with a silica gel column and a silver ion column that was applied to preparative separation of these two isomers from a traditional Chinese medicine, Inula racemosa Hook.f., was established. The results showed that the online heart-cutting LC-LC technique by combination of a silica gel column and a silver ion column for the preparative separation of these two positional isomers from this natural plant was superior to the preparative separation performed on a single-column system with C 18 column or silica gel column. Copyright © 2018 Elsevier B.V. All rights reserved.

  9. Technique for measuring cooling patterns in ion source grids by infrared scanning

    Grisham, L.R.; Eubank, H.P.; Kugel, H.W.

    1980-02-01

    Many plasma sources designed for neutral beam injection heating of plasmas now employ copper beam acceleration grids which are water-cooled by small capillary tubes fed from one or more headers. To prevent thermally-induced warpage of these grids it is essential that one be able to detect inhomogeneities in the cooling. Due to the very strong thermal coupling between adjacent cooling lines and the concomitant rapid equilibration times, it is not practical to make such measurements in a direct manner with a contact thermometer. We have developed a technique whereby we send a burst of hot water through an initially cool grid, followed by a burst of cool water, and record the transient thermal behavior usng an infrared television camera. This technique, which would be useful for any system with cooling paths that are strongly coupled thermally, has been applied to a number of sources built for the PLT and PDX tokamaks, and has proven highly effective in locating cooling deficiencies and blocked capillary tubes

  10. Emissions of volatile organic compounds (VOCs) from concentrated animal feeding operations (CAFOs): chemical compositions and separation of sources

    Yuan, Bin; Coggon, Matthew M.; Koss, Abigail R.; Warneke, Carsten; Eilerman, Scott; Peischl, Jeff; Aikin, Kenneth C.; Ryerson, Thomas B.; de Gouw, Joost A.

    2017-04-01

    Concentrated animal feeding operations (CAFOs) emit a large number of volatile organic compounds (VOCs) to the atmosphere. In this study, we conducted mobile laboratory measurements of VOCs, methane (CH4) and ammonia (NH3) downwind of dairy cattle, beef cattle, sheep and chicken CAFO facilities in northeastern Colorado using a hydronium ion time-of-flight chemical-ionization mass spectrometer (H3O+ ToF-CIMS), which can detect numerous VOCs. Regional measurements of CAFO emissions in northeastern Colorado were also performed using the NOAA WP-3D aircraft during the Shale Oil and Natural Gas Nexus (SONGNEX) campaign. Alcohols and carboxylic acids dominate VOC concentrations and the reactivity of the VOCs with hydroxyl (OH) radicals. Sulfur-containing and phenolic species provide the largest contributions to the odor activity values and the nitrate radical (NO3) reactivity of VOC emissions, respectively. VOC compositions determined from mobile laboratory and aircraft measurements generally agree well with each other. The high time-resolution mobile measurements allow for the separation of the sources of VOCs from different parts of the operations occurring within the facilities. We show that the emissions of ethanol are primarily associated with feed storage and handling. Based on mobile laboratory measurements, we apply a multivariate regression analysis using NH3 and ethanol as tracers to determine the relative importance of animal-related emissions (animal exhalation and waste) and feed-related emissions (feed storage and handling) for different VOC species. Feed storage and handling contribute significantly to emissions of alcohols, carbonyls, carboxylic acids and sulfur-containing species. Emissions of phenolic species and nitrogen-containing species are predominantly associated with animals and their waste.

  11. Characterisation of the biochemical methane potential (BMP) of individual material fractions in Danish source-separated organic household waste.

    Naroznova, Irina; Møller, Jacob; Scheutz, Charlotte

    2016-04-01

    This study is dedicated to characterising the chemical composition and biochemical methane potential (BMP) of individual material fractions in untreated Danish source-separated organic household waste (SSOHW). First, data on SSOHW in different countries, available in the literature, were evaluated and then, secondly, laboratory analyses for eight organic material fractions comprising Danish SSOHW were conducted. No data were found in the literature that fully covered the objectives of the present study. Based on laboratory analyses, all fractions were assigned according to their specific properties in relation to BMP, protein content, lipids, lignocellulose biofibres and easily degradable carbohydrates (carbohydrates other than lignocellulose biofibres). The three components in lignocellulose biofibres, i.e. lignin, cellulose and hemicellulose, were differentiated, and theoretical BMP (TBMP) and material degradability (BMP from laboratory incubation tests divided by TBMP) were expressed. Moreover, the degradability of lignocellulose biofibres (the share of volatile lignocellulose biofibre solids degraded in laboratory incubation tests) was calculated. Finally, BMP for average SSOHW composition in Denmark (untreated) was calculated, and the BMP contribution of the individual material fractions was then evaluated. Material fractions of the two general waste types, defined as "food waste" and "fibre-rich waste," were found to be anaerobically degradable with considerable BMP. Material degradability of material fractions such as vegetation waste, moulded fibres, animal straw, dirty paper and dirty cardboard, however, was constrained by lignin content. BMP for overall SSOHW (untreated) was 404 mL CH4 per g VS, which might increase if the relative content of material fractions, such as animal and vegetable food waste, kitchen tissue and dirty paper in the waste, becomes larger. Copyright © 2016 Elsevier Ltd. All rights reserved.

  12. Growth and yield of tomato cultivated on composted duck excreta enriched wood shavings and source-separated municipal solid waste

    Vincent Zoes

    2011-02-01

    Full Text Available A greenhouse experiment was conducted to evaluate the use of growth substrates, made with duck excreta enriched wood shaving compost (DMC and the organic fraction of source-separated municipal solid waste (MSW compost, on the growth and yield of tomato (Lycopersicum esculentum Mill. cv. Campbell 1327. Substrate A consisted of 3:2 (W/W proportion of DMC and MSW composts. Substrates B and C were the same as A but contained 15% (W/W ratio of brick dust and shredded plastic, respectively. Three control substrates consisted of the commercially available peat-based substrate (Pr, an in-house sphagnum peat-based substrate (Gs, and black earth mixed with sandy loam soil (BE/S in a 1:4 (W/W ratio. Substrates (A, B, C and controls received nitrogen (N, phosphate (P and potassium (K at equivalent rates of 780 mg/pot, 625 mg/pot, and 625 mg/pot, respectively, or were used without mineral fertilizers. Compared to the controls (Pr, Gs and BE/S, tomato plants grown on A, B, and C produced a greater total number and dry mass of fruits, with no significant differences between them. On average, total plant dry-matter biomass in substrate A, B, and C was 19% lower than that produced on Pr, but 28% greater than biomass obtained for plant grown, on Gs and BE/S. Plant height, stem diameter and chlorophyll concentrations indicate that substrates A, B, and C were particularly suitable for plant growth. Although the presence of excess N in composted substrates favoured vegetative rather than reproductive growth, the continuous supply of nutrients throughout the growing cycle, as well as the high water retention capacity that resulted in a reduced watering by 50%, suggest that substrates A, B, and C were suitable growing mixes, offering environmental and agronomic advantages.

  13. The potential of organic (electrospray- and atmospheric pressure chemical ionisation) mass spectrometric techniques coupled to liquid-phase separation for speciation analysis.

    Rosenberg, Erwin

    2003-06-06

    The use of mass spectrometry based on atmospheric pressure ionisation techniques (atmospheric pressure chemical ionisation, APCI, and electrospray ionisation, ESI) for speciation analysis is reviewed with emphasis on the literature published in and after 1999. This report accounts for the increasing interest that atmospheric pressure ionisation techniques, and in particular ESI, have found in the past years for qualitative and quantitative speciation analysis. In contrast to element-selective detectors, organic mass spectrometric techniques provide information on the intact metal species which can be used for the identification of unknown species (particularly with MS-MS detection) or the confirmation of the actual presence of species in a given sample. Due to the complexity of real samples, it is inevitable in all but the simplest cases to couple atmospheric pressure MS detection to a separation technique. Separation in the liquid phase (capillary electrophoresis or liquid chromatography in reversed phase, ion chromatographic or size-exclusion mode) is particularly suitable since the available techniques cover a very wide range of analyte polarities and molecular mass. Moreover, derivatisation can normally be avoided in liquid-phase separation. Particularly in complex environmental or biological samples, separation in one dimension is not sufficient for obtaining adequate resolution for all relevant species. In this case, multi-dimensional separation, based on orthogonal separation techniques, has proven successful. ESI-MS is also often used in parallel with inductively coupled plasma MS detection. This review is structured in two parts. In the first, the fundamentals of atmospheric pressure ionisation techniques are briefly reviewed. The second part of the review discusses recent applications including redox species, use of ESI-MS for structural elucidation of metal complexes, characterisation and quantification of small organometallic species with relevance to

  14. Characterization techniques for the high-brightness particle beams of the Advanced Photon Source (APS)

    Lumpkin, A.H.

    1993-01-01

    The Advanced Photon Source (APS) will be a third-generation synchrotron radiation (SR) user facility in the hard x-ray regime (10--100 keV). The design objectives for the 7-GeV storage ring include a positron beam natural emittance of 8 x 10 -9 m-rad at an average current of 100 mA. Proposed methods for measuring the transverse and longitudinal profiles will be described. Additionally, a research and development effort using an rf gun as a low-emittance source of electrons for injection into the 200- to 650-MeV linac subsystem is underway. This latter system is projected to produce electron beams with a normalized, rms emittance of ∼2 π mm-mrad at peak currents of near one hundred amps. This interesting characterization problem will also be briefly discussed. The combination of both source types within one laboratory facility will stimulate the development of diagnostic techniques in these parameter spaces

  15. Identification of Sparse Audio Tampering Using Distributed Source Coding and Compressive Sensing Techniques

    Valenzise G

    2009-01-01

    Full Text Available In the past few years, a large amount of techniques have been proposed to identify whether a multimedia content has been illegally tampered or not. Nevertheless, very few efforts have been devoted to identifying which kind of attack has been carried out, especially due to the large data required for this task. We propose a novel hashing scheme which exploits the paradigms of compressive sensing and distributed source coding to generate a compact hash signature, and we apply it to the case of audio content protection. The audio content provider produces a small hash signature by computing a limited number of random projections of a perceptual, time-frequency representation of the original audio stream; the audio hash is given by the syndrome bits of an LDPC code applied to the projections. At the content user side, the hash is decoded using distributed source coding tools. If the tampering is sparsifiable or compressible in some orthonormal basis or redundant dictionary, it is possible to identify the time-frequency position of the attack, with a hash size as small as 200 bits/second; the bit saving obtained by introducing distributed source coding ranges between 20% to 70%.

  16. Radiotracer and sealed source techniques for sediment management. Report of the consultants meeting

    2008-01-01

    Radioisotopes as tracers and sealed sources have been a useful and often irreplaceable tool for sediment transport studies. Gamma scattering and transmission gauges are used for sediment monitoring. Computational fluid dynamics (CFD) modelling is now an essential tool for the management of the natural systems and are increasingly used to study the fate and behaviour of particulates and contaminants. Radiotracer techniques are often employed to validate CFD models to enhance confidence in the predictive value of the models. Experimental tracing and numerical modelling are complementary methods of studying complex systems. During the last few decades, many radiotracer studies for the investigation of sediment transport in natural systems have been conducted worldwide, and various techniques for tracing and monitoring sediment have been developed by individual tracer groups. However, the developed techniques and methods for sediment tracing have not been compiled yet as a technical document, which is essential for the preservation of the knowledge and transfer of the technology to developing countries. Standard procedures or guidelines for the tracer experiments, which are vital for the reliability of the experiments and the acceptance of end-users, have not been established by the international tracer community either. The use of radiotracers in sediment transport studies demands the additional attention of the community to further develop these techniques and to ensure their transfer to developing countries. The Consultants' Meeting on 'Radiotracer and sealed source techniques for sediment management' was convened at the headquarters of the International Atomic Energy Agency (IAEA) in Vienna, Austria, from 21 to 25 April 2008. Experts from Argentina, Brazil, France, India, Republic of Korea and United Kingdom have been invited to discuss the current status of the tracer and nucleonic gauge technologies as applied for sediment transport investigations and to evaluate

  17. Radiotracer and sealed source techniques for sediment management. Report of the consultants meeting

    NONE

    2008-07-01

    Radioisotopes as tracers and sealed sources have been a useful and often irreplaceable tool for sediment transport studies. Gamma scattering and transmission gauges are used for sediment monitoring. Computational fluid dynamics (CFD) modelling is now an essential tool for the management of the natural systems and are increasingly used to study the fate and behaviour of particulates and contaminants. Radiotracer techniques are often employed to validate CFD models to enhance confidence in the predictive value of the models. Experimental tracing and numerical modelling are complementary methods of studying complex systems. During the last few decades, many radiotracer studies for the investigation of sediment transport in natural systems have been conducted worldwide, and various techniques for tracing and monitoring sediment have been developed by individual tracer groups. However, the developed techniques and methods for sediment tracing have not been compiled yet as a technical document, which is essential for the preservation of the knowledge and transfer of the technology to developing countries. Standard procedures or guidelines for the tracer experiments, which are vital for the reliability of the experiments and the acceptance of end-users, have not been established by the international tracer community either. The use of radiotracers in sediment transport studies demands the additional attention of the community to further develop these techniques and to ensure their transfer to developing countries. The Consultants' Meeting on 'Radiotracer and sealed source techniques for sediment management' was convened at the headquarters of the International Atomic Energy Agency (IAEA) in Vienna, Austria, from 21 to 25 April 2008. Experts from Argentina, Brazil, France, India, Republic of Korea and United Kingdom have been invited to discuss the current status of the tracer and nucleonic gauge technologies as applied for sediment transport investigations and to evaluate

  18. Identifying the sources of produced water in the oil field by isotopic techniques

    Nguyen Minh Quy; Hoang Long; Le Thi Thu Huong; Luong Van Huan; Vo Thi Tuong Hanh

    2014-01-01

    The objective of this study is to identify the sources of the formation water in the Southwest Su-Tu-Den (STD SW) basement reservoir. To achieve the objective, isotopic techniques along with geochemical analysis for chloride, bromide, strontium dissolved in the water were applied. The isotopic techniques used in this study were the determination of water stable isotopes signatures (δ 2 H and (δ 18 O) and of the 87 Sr/ 86 Sr ratio of strontium in rock cutting sample and that dissolved in the formation water. The obtained results showed that the stable isotopes compositions of water in the Lower Miocene was -3‰ and -23‰ for (δ 18 O and (δ 2 H, respectively indicating the primeval nature of seawater in the reservoir. Meanwhile, the isotopic composition of water in the basement was clustered in a range of alternated freshwater with (δ 18 O and (δ 2 H being -(3-4)‰ and -(54-60)‰, respectively). The strontium isotopes ratio for water in the Lower Miocene reservoir was lower compared to that for water in the basement confirming the different natures of the water in the two reservoirs. The obtained results are assured for the techniques applicability, and it is recommended that studies on identification of the flow-path of the formation water in the STD SW basement reservoir should be continued. (author)

  19. Comparison between immunomagnetic separation, coupled with immunofluorescence, and the techniques of Faust et al. and of Lutz for the diagnosis of Giardia lamblia cysts in human feces

    Souza Doris Sobral Marques

    2003-01-01

    Full Text Available In the present study, the performance of Immunomagnetic Separation technique, coupled with Immunofluorescence (IMS-IFA, was compared with the FAUST et al. and Lutz parasitological techniques for the detection of Giardia lamblia cysts in human feces. One hundred and twenty-seven samples were evaluated by the three techniques at the same time showing a rate of cyst detection of 27.5% by IMS-IFA and 15.7% by both Faust et al. and Lutz techniques. Data analysis showed a higher sensitivity of IMS-IFA for the detection of G. lamblia cysts in comparison with the techniques of FAUST et al. and Lutz. The use of this methodology as a routine procedure enables the processing of many samples simultaneously, in order to increase recovery rate of G. lamblia cysts and reduce the time of sample storage.

  20. Comparison of residual NAPL source removal techniques in 3D metric scale experiments

    Atteia, O.; Jousse, F.; Cohen, G.; Höhener, P.

    2017-07-01

    This study compared four treatment techniques for the removal of a toluene/n-decane as NAPL (Non Aqueous Phase Liquid) phase mixture in identical 1 cubic meter tanks filled with different kind of sand. These four treatment techniques were: oxidation with persulfate, surfactant washing with Tween80®, sparging with air followed by ozone, and thermal treatment at 80 °C. The sources were made with three lenses of 26 × 26 × 6.5 cm, one having a hydraulic conductivity similar to the whole tank and the two others a value 10 times smaller. The four techniques were studied after conditioning the tanks with tap water during approximately 80 days. The persulfate treatment tests showed average removal of the contaminants but significant flux decrease if density effects are considered. Surfactant flushing did not show a highly significant increase of the flux of toluene but allowed an increased removal rate that could lead to an almost complete removal with longer treatment time. Sparging removed a significant amount but suggests that air was passing through localized gas channels and that the removal was stagnating after removing half of the contamination. Thermal treatment reached 100% removal after the target temperature of 80 °C was kept during more than 10 d. The experiments emphasized the generation of a high-spatial heterogeneity in NAPL content. For all the treatments the overall removal was similar for both n-decane and toluene, suggesting that toluene was removed rapidly and n-decane more slowly in some zones, while no removal existed in other zones. The oxidation and surfactant results were also analyzed for the relation between contaminant fluxes at the outlet and mass removal. For the first time, this approach clearly allowed the differentiation of the treatments. As a conclusion, experiments showed that the most important differences between the tested treatment techniques were not the global mass removal rates but the time required to reach 99% decrease in

  1. Isotopic separation

    Chen, C.L.

    1982-01-01

    A method is described for separating isotopes in which photo-excitation of selected isotope species is used together with the reaction of the excited species with postive ions of predetermined ionization energy, other excited species, or free electrons to produce ions or ion fragments of the selected species. Ions and electrons are produced by an electrical discharge, and separation is achieved through radial ambipolar diffusion, electrostatic techniques, or magnetohydrodynamic methods

  2. Pig slurry acidification and separation techniques affect soil N and C turnover and N2O emissions from solid, liquid and biochar fractions

    Gomez Muñoz, Beatriz; Case, Sean; Jensen, Lars Stoumann

    2016-01-01

    the separated solid fractions in soil, but did not affect N2O and CO2 emissions. However acidification reduced soil N and C turnover from the liquid fraction. The use of more advanced separation techniques (flocculation and drainage > decanting centrifuge > screw press) increased N mineralisation from acidified...... solid fractions, but also increased N2O and CO2 emissions in soil amended with the liquid fraction. Finally, the biochar production from the solid fraction of pig slurry resulted in a very recalcitrant material, which reduced N and C mineralisation in soil compared to the raw solid fractions....

  3. Magnetic separation technique for groundwater by five HTS melt-processed bulk magnets arranged in a line

    Oka, T.; Seki, H.; Kimura, T.; Mimura, D.; Fukui, S.; Ogawa, J.; Sato, T.; Ooizumi, M.; Fujishiro, H.; Hayashi, H.; Yokoyama, K.; Stiehler, C.

    2011-01-01

    A magnetic separation was practically conducted by 10-pole HTS bulk magnets. The HTS bulk magnets were activated to 2.5 T by feeding pulsed fields of 6 T. The separation ratio of actual groundwater exceeded 70% at less than 4.8 l/min. The flocks without magnetite powder were obviously attracted to the magnetic poles. A magnetic separation study for groundwater purification has been practically conducted by using the multi-pole magnet system. The magnetic pole was composed of 10 open magnetic spaces by arranging five HTS melt-processed bulk magnets in a line in a vacuum sheath. The individual bulk magnets were activated by feeding intense pulsed magnetic fields up to 6 T. The magnetic field distribution was estimated with respect to various pole arrangements. The actual groundwater samples of Sanjo City were processed so as to form large precipitates by adding the coagulant and pH controlling. The maximum separation ratio of the iron-bearing precipitates has exceeded over 70% when slurry water was exposed to 10 magnetic poles of up to 2.5 T at a flowing rate of less than 4.8 l/min. An obvious attraction of flocks to the magnetic poles was observed even when the water contains no magnetite powder at the flow rate of 1.01 l/min. This implies the validity of the multi-pole magnet system with respect to the actual application to water purification.

  4. Remote defect imaging for plate-like structures based on the scanning laser source technique

    Hayashi, Takahiro; Maeda, Atsuya; Nakao, Shogo

    2018-04-01

    In defect imaging with a scanning laser source technique, the use of a fixed receiver realizes stable measurements of flexural waves generated by laser at multiple rastering points. This study discussed the defect imaging by remote measurements using a laser Doppler vibrometer as a receiver. Narrow-band burst waves were generated by modulating laser pulse trains of a fiber laser to enhance signal to noise ratio in frequency domain. Averaging three images obtained at three different frequencies suppressed spurious distributions due to resonance. The experimental system equipped with these newly-devised means enabled us to visualize defects and adhesive objects in plate-like structures such as a plate with complex geometries and a branch pipe.

  5. Observation of {gamma}-sources using a new reconstruction technique in the CLUE experiment

    Bartoli, B.; Bastieri, D.; Bigongiari, C.; Biral, R.; Ciocci, M.A.; Cresti, M.; Dokoutchaeva, V.; Kartashov, D.; Liello, F.; Malakhov, N.; Mariotti, M.; Marsella, G.; Menzione, A.; Paoletti, R.; Peruzzo, L.; Piccioli, A.; Pegna, R.; Rosso, F.; Saggion, A.; Sartori, G.; Sbarra, C.; Scribano, A.; Smogailov, E.; Stamerra, A.; Turini, N

    2001-04-01

    The CLUE experiment, located in La Palma island at 2200 m a.s.l., is an array of 3x3 telescope, detecting the UV (190 - 230 nm) Cherenkov light produced by atmospheric showers. Since atmospheric absorption in the UV range is higher than in the visible range, CLUE cannot apply existing algorithms normally used in IACT experiments to determine primary cosmic ray direction. In this paper we present a new method developed by CLUE. The algorithm performances were evaluated using simulated showers. Using the new technique, preliminary results of last two years observational campaigns on the Crab Nebula and on Markarian 421 are presented, showing a clear signal on both sources. The CLUE experiment collected also data with the telescopes aiming directly at the Moon: we expect improvements also on the Moon Shadow measurement adopting the new method.

  6. Observation of γ-sources using a new reconstruction technique in the CLUE experiment

    Bartoli, B.; Bastieri, D.; Bigongiari, C.; Biral, R.; Ciocci, M.A.; Cresti, M.; Dokoutchaeva, V.; Kartashov, D.; Liello, F.; Malakhov, N.; Mariotti, M.; Marsella, G.; Menzione, A.; Paoletti, R.; Peruzzo, L.; Piccioli, A.; Pegna, R.; Rosso, F.; Saggion, A.; Sartori, G.; Sbarra, C.; Scribano, A.; Smogailov, E.; Stamerra, A.; Turini, N.

    2001-01-01

    The CLUE experiment, located in La Palma island at 2200 m a.s.l., is an array of 3x3 telescope, detecting the UV (190 - 230 nm) Cherenkov light produced by atmospheric showers. Since atmospheric absorption in the UV range is higher than in the visible range, CLUE cannot apply existing algorithms normally used in IACT experiments to determine primary cosmic ray direction. In this paper we present a new method developed by CLUE. The algorithm performances were evaluated using simulated showers. Using the new technique, preliminary results of last two years observational campaigns on the Crab Nebula and on Markarian 421 are presented, showing a clear signal on both sources. The CLUE experiment collected also data with the telescopes aiming directly at the Moon: we expect improvements also on the Moon Shadow measurement adopting the new method

  7. Gas Source Techniques for Molecular Beam Epitaxy of Highly Mismatched Ge Alloys

    Chad A. Stephenson

    2016-12-01

    Full Text Available Ge and its alloys are attractive candidates for a laser compatible with silicon integrated circuits. Dilute germanium carbide (Ge1−xCx offers a particularly interesting prospect. By using a precursor gas with a Ge4C core, C can be preferentially incorporated in substitutional sites, suppressing interstitial and C cluster defects. We present a method of reproducible and upscalable gas synthesis of tetrakis(germylmethane, or (H3Ge4C, followed by the design of a hybrid gas/solid-source molecular beam epitaxy system and subsequent growth of defect-free Ge1−xCx by molecular beam epitaxy (MBE. Secondary ion mass spectroscopy, transmission electron microscopy and contactless electroreflectance confirm the presence of carbon with very high crystal quality resulting in a decrease in the direct bandgap energy. This technique has broad applicability to growth of highly mismatched alloys by MBE.

  8. Applying inversion techniques to derive source currents and geoelectric fields for geomagnetically induced current calculations

    J. S. de Villiers

    2014-10-01

    Full Text Available This research focuses on the inversion of geomagnetic variation field measurement to obtain source currents in the ionosphere. During a geomagnetic disturbance, the ionospheric currents create magnetic field variations that induce geoelectric fields, which drive geomagnetically induced currents (GIC in power systems. These GIC may disturb the operation of power systems and cause damage to grounded power transformers. The geoelectric fields at any location of interest can be determined from the source currents in the ionosphere through a solution of the forward problem. Line currents running east–west along given surface position are postulated to exist at a certain height above the Earth's surface. This physical arrangement results in the fields on the ground having the magnetic north and down components, and the electric east component. Ionospheric currents are modelled by inverting Fourier integrals (over the wavenumber of elementary geomagnetic fields using the Levenberg–Marquardt technique. The output parameters of the inversion model are the current strength, height and surface position of the ionospheric current system. A ground conductivity structure with five layers from Quebec, Canada, based on the Layered-Earth model is used to obtain the complex skin depth at a given angular frequency. This paper presents preliminary and inversion results based on these structures and simulated geomagnetic fields. The results show some interesting features in the frequency domain. Model parameters obtained through inversion are within 2% of simulated values. This technique has applications for modelling the currents of electrojets at the equator and auroral regions, as well as currents in the magnetosphere.

  9. Efficacy of Blood Sources and Artificial Blood Feeding Methods in Rearing of Aedes aegypti (Diptera: Culicidae for Sterile Insect Technique and Incompatible Insect Technique Approaches in Sri Lanka

    Nayana Gunathilaka

    2017-01-01

    Full Text Available Introduction. Selection of the artificial membrane feeding technique and blood meal source has been recognized as key considerations in mass rearing of vectors. Methodology. Artificial membrane feeding techniques, namely, glass plate, metal plate, and Hemotek membrane feeding method, and three blood sources (human, cattle, and chicken were evaluated based on feeding rates, fecundity, and hatching rates of Aedes aegypti. Significance in the variations among blood feeding was investigated by one-way ANOVA, cluster analysis of variance (ANOSIM, and principal coordinates (PCO analysis. Results. Feeding rates of Ae. aegypti significantly differed among the membrane feeding techniques as suggested by one-way ANOVA (p0.05. Conclusions. Metal plate method could be recommended as the most effective membrane feeding technique for mass rearing of Ae. aegypti, due to its high feeding rate and cost effectiveness. Cattle blood could be recommended for mass rearing Ae. aegypti.

  10. Techniques for enhancing the performance of high charge state ECR ion sources

    Xie, Z.Q.

    1999-01-01

    Electron Cyclotron Resonance ion source (ECRIS), which produces singly to highly charged ions, is widely used in heavy ion accelerators and is finding applications in industry. It has progressed significantly in recent years thanks to a few techniques, such as multiple-frequency plasma heating, higher mirror magnetic fields and a better cold electron donor. These techniques greatly enhance the production of highly charged ions. More than 1 emA of He 2+ and O 6+ , hundreds of eμA of O 7+ , Ne 8+ , Ar 12+ , more than 100 eμA of intermediate heavy ions with charge states up to Ne 9+ , Ar 13+ , Ca 13+ , Fe 13+ , Co 14+ and Kr 18+ , tens of eμA of heavy ions with charge states up to Xe 28+ , Au 35+ , Bi 34+ and U 34+ were produced at cw mode operation. At an intensity of about 1 eμA, the charge states for the heavy ions increased up to Xe 36+ , Au 46+ , Bi 47+ and U 48+ . More than an order of magnitude enhancement of fully stripped argon ions was achieved (I≥0.1 and h;eμA). Higher charge state ions up to Kr 35+ , Xe 46+ and U 64+ at low intensities were produced for the first time from an ECRIS. copyright 1999 American Institute of Physics

  11. Study to prepare 201Tl by irradiation of mercury with protons. Application of extraction chromatography technique in separation of thallium and mercury

    Fernandes, L.; Silva, C.P.G. da

    1986-01-01

    The extraction chromatography technique was used for the lig and 201 Tl separation. It was used glass columns of 5,0 cm height and 1,0 cm diameter filled with Voltalef powder impregnated with TBP/cyclohexane. By the Voltalef columns solutions of 203 Hg 2+ , 201 Tl 1+ and 20 1Te 3 were separately percolated in a nitric environment of 4 to 8 M concentration and in a hydrochloridric environment of 0,5 to 4 M. The separation of Hg and 201 Tl was obtained by the retention of 201 Tl3 + in the column during the elution of all the Hg with HCl 2 M. The 201 Tl 3+ was eluted from the column after its reduction with a hot hydrazine dichloride solution. (Author) [pt

  12. A technique to consider mismatches between fMRI and EEG/MEG sources for fMRI-constrained EEG/MEG source imaging: a preliminary simulation study

    Im, Chang-Hwan; Lee, Soo Yeol

    2006-01-01

    fMRI-constrained EEG/MEG source imaging can be a powerful tool in studying human brain functions with enhanced spatial and temporal resolutions. Recent studies on the combination of fMRI and EEG/MEG have suggested that fMRI prior information could be readily implemented by simply imposing different weighting factors to cortical sources overlapping with the fMRI activations. It has been also reported, however, that such a hard constraint may cause severe distortions or elimination of meaningful EEG/MEG sources when there are distinct mismatches between the fMRI activations and the EEG/MEG sources. If one wants to obtain the actual EEG/MEG source locations and uses the fMRI prior information as just an auxiliary tool to enhance focality of the distributed EEG/MEG sources, it is reasonable to weaken the strength of fMRI constraint when severe mismatches between fMRI and EEG/MEG sources are observed. The present study suggests an efficient technique to automatically adjust the strength of fMRI constraint according to the mismatch level. The use of the proposed technique rarely affects the results of conventional fMRI-constrained EEG/MEG source imaging if no major mismatch between the two modalities is detected; while the new results become similar to those of typical EEG/MEG source imaging without fMRI constraint if the mismatch level is significant. A preliminary simulation study using realistic EEG signals demonstrated that the proposed technique can be a promising tool to selectively apply fMRI prior information to EEG/MEG source imaging

  13. Accuracy of a separating foil impression using a novel polyolefin foil compared to a custom tray and a stock tray technique

    Pastoret, Marie-Hélène; Bühler, Julia; Weiger, Roland

    2017-01-01

    PURPOSE To compare the dimensional accuracy of three impression techniques- a separating foil impression, a custom tray impression, and a stock tray impression. MATERIALS AND METHODS A machined mandibular complete-arch metal model with special modifications served as a master cast. Three different impression techniques (n = 6 in each group) were performed with addition-cured silicon materials: i) putty-wash technique with a prefabricated metal tray (MET) using putty and regular body, ii) single-phase impression with custom tray (CUS) using regular body material, and iii) two-stage technique with stock metal tray (SEP) using putty with a separating foil and regular body material. All impressions were poured with epoxy resin. Six different distances (four intra-abutment and two inter-abutment distances) were gauged on the metal master model and on the casts with a microscope in combination with calibrated measuring software. The differences of the evaluated distances between the reference and the three test groups were calculated and expressed as mean (± SD). Additionally, the 95% confidence intervals were calculated and significant differences between the experimental groups were assumed when confidence intervals did not overlap. RESULTS Dimensional changes compared to reference values varied between -74.01 and 32.57 µm (MET), -78.86 and 30.84 (CUS), and between -92.20 and 30.98 (SEP). For the intra-abutment distances, no significant differences among the experimental groups were detected. CUS showed a significantly higher dimensional accuracy for the inter-abutment distances with -0.02 and -0.08 percentage deviation compared to MET and SEP. CONCLUSION The separation foil technique is a simple alternative to the custom tray technique for single tooth restorations, while limitations may exist for extended restorations with multiple abutment teeth. PMID:28874996

  14. Experimental substantiation of separation techniques of lead and uranium microamounts using isotopic dilution method as control method

    Agapova, A.A.; Shcherbinina, N.K.

    1983-01-01

    Methods,ensuring at low levels of contamination a high degree of lead and uranium microamount separation from solutions of geological samples, have been selected and subjected to the detailed testing. The method of isotope dilution, , combining high accuracy and sensitivity of determinations, is used as the main control methods, is used as the main control method. Using the method, processe es of uranium extpaction are traced, special attention is paid to the detailed description of lead extraction at all the stages of the methods selected. Opera ations of ion exchange for lead and uranium in microcolumns with the Bio-Rad r sin are considered, as well as operations of lead electrolytic separation. The chemical procedures suggested permit to solve one of the main methodical tasks f sample preparation, containing microgram amounts of lead and uranium, for high h-prcision measurement of their isotope composition using mass-spectrometric method

  15. Domestic wash water reclamation for reuse as commode water supply using filtration: Reverse-osmosis separation technique

    Hall, J. B., Jr.; Batten, C. E.; Wilkins, J. R.

    1974-01-01

    A combined filtration-reverse-osmosis water recovery system has been evaluated to determine its capability to reclaim domestic wash water for reuse as a commode water supply. The system produced water that met all chemical and physical requirements established by the U.S. Public Health Service for drinking water with the exception of carbon chloroform extractables, methylene blue active substances, and phenols. It is thought that this water is of sufficient quality to be reused as commode supply water. The feasibility of using a combined filtration and reverse-osmosis technique for reclaiming domestic wash water has been established. The use of such a technique for wash-water recovery will require a maintenance filter to remove solid materials including those less than 1 micron in size from the wash water. The reverse-osmosis module, if sufficiently protected from plugging, is an attractive low-energy technique for removing contaminants from domestic wash water.

  16. Residents’ Waste Separation Behaviors at the Source: Using SEM with the Theory of Planned Behavior in Guangzhou, China

    Zhang, Dongliang; Huang, Guangqing; Yin, Xiaoling; Gong, Qinghua

    2015-01-01

    Understanding the factors that affect residents’ waste separation behaviors helps in constructing effective environmental campaigns for a community. Using the theory of planned behavior (TPB), this study examines factors associated with waste separation behaviors by analyzing responses to questionnaires distributed in Guangzhou, China. Data drawn from 208 of 1000-field questionnaires were used to assess socio-demographic factors and the TPB constructs (i.e., attitudes, subjective norms, perceived behavioral control, intentions, and situational factors). The questionnaire data revealed that attitudes, subjective norms, perceived behavioral control, intentions, and situational factors significantly predicted household waste behaviors in Guangzhou, China. Through a structural equation modeling analysis, we concluded that campaigns targeting moral obligations may be particularly effective for increasing the participation rate in waste separation behaviors. PMID:26274969

  17. Source Identification of Heavy Metals in Soils Surrounding the Zanjan Zinc Town by Multivariate Statistical Techniques

    M.A. Delavar

    2016-02-01

    Full Text Available Introduction: The accumulation of heavy metals (HMs in the soil is of increasing concern due to food safety issues, potential health risks, and the detrimental effects on soil ecosystems. HMs may be considered as the most important soil pollutants, because they are not biodegradable and their physical movement through the soil profile is relatively limited. Therefore, root uptake process may provide a big chance for these pollutants to transfer from the surface soil to natural and cultivated plants, which may eventually steer them to human bodies. The general behavior of HMs in the environment, especially their bioavailability in the soil, is influenced by their origin. Hence, source apportionment of HMs may provide some essential information for better management of polluted soils to restrict the HMs entrance to the human food chain. This paper explores the applicability of multivariate statistical techniques in the identification of probable sources that can control the concentration and distribution of selected HMs in the soils surrounding the Zanjan Zinc Specialized Industrial Town (briefly Zinc Town. Materials and Methods: The area under investigation has a size of approximately 4000 ha.It is located around the Zinc Town, Zanjan province. A regular grid sampling pattern with an interval of 500 meters was applied to identify the sample location, and 184 topsoil samples (0-10 cm were collected. The soil samples were air-dried and sieved through a 2 mm polyethylene sieve and then, were digested using HNO3. The total concentrations of zinc (Zn, lead (Pb, cadmium (Cd, Nickel (Ni and copper (Cu in the soil solutions were determined via Atomic Absorption Spectroscopy (AAS. Data were statistically analyzed using the SPSS software version 17.0 for Windows. Correlation Matrix (CM, Principal Component Analyses (PCA and Factor Analyses (FA techniques were performed in order to identify the probable sources of HMs in the studied soils. Results and

  18. An application of time-frequency signal analysis technique to estimate the location of an impact source on a plate type structure

    Park, Jin Ho; Lee, Jeong Han; Choi, Young Chul; Kim, Chan Joong; Seong, Poong Hyun

    2005-01-01

    It has been reviewed whether it would be suitable that the application of the time-frequency signal analysis techniques to estimate the location of the impact source in plate structure. The STFT(Short Time Fourier Transform), WVD(Wigner-Ville distribution) and CWT(Continuous Wavelet Transform) methods are introduced and the advantages and disadvantages of those methods are described by using a simulated signal component. The essential of the above proposed techniques is to separate the traveling waves in both time and frequency domains using the dispersion characteristics of the structural waves. These time-frequency methods are expected to be more useful than the conventional time domain analyses for the impact localization problem on a plate type structure. Also it has been concluded that the smoothed WVD can give more reliable means than the other methodologies for the location estimation in a noisy environment

  19. Separation of radiated sound field components from waves scattered by a source under non-anechoic conditions

    Fernandez Grande, Efren; Jacobsen, Finn

    2010-01-01

    to the source. Thus the radiated free-field component is estimated simultaneously with solving the inverse problem of reconstructing the sound field near the source. The method is particularly suited to cases in which the overall contribution of reflected sound in the measurement plane is significant....

  20. Microparticle Separation by Cyclonic Separation

    Karback, Keegan; Leith, Alexander

    2017-11-01

    The ability to separate particles based on their size has wide ranging applications from the industrial to the medical. Currently, cyclonic separators are primarily used in agriculture and manufacturing to syphon out contaminates or products from an air supply. This has led us to believe that cyclonic separation has more applications than the agricultural and industrial. Using the OpenFoam computational package, we were able to determine the flow parameters of a vortex in a cyclonic separator in order to segregate dust particles to a cutoff size of tens of nanometers. To test the model, we constructed an experiment to separate a test dust of various sized particles. We filled a chamber with Arizona test dust and utilized an acoustic suspension technique to segregate particles finer than a coarse cutoff size and introduce them into the cyclonic separation apparatus where they were further separated via a vortex following our computational model. The size of the particles separated from this experiment will be used to further refine our model. Metropolitan State University of Denver, Colorado University of Denver, Dr. Randall Tagg, Dr. Richard Krantz.

  1. Introducing Students to Protein Analysis Techniques: Separation and Comparative Analysis of Gluten Proteins in Various Wheat Strains

    Pirinelli, Alyssa L.; Trinidad, Jonathan C.; Pohl, Nicola L. B.

    2016-01-01

    Polyacrylamide gel electrophoresis (PAGE) is commonly taught in undergraduate laboratory classes as a traditional method to analyze proteins. An experiment has been developed to teach these basic protein gel skills in the context of gluten protein isolation from various types of wheat flour. A further goal is to relate this technique to current…

  2. Improving the corn-ethanol industry: studying protein separation techniques to obtain higher value added product options for distillers grains

    Brehmer, B.; Bals, B.; Sanders, J.P.M.; Dale, B.

    2008-01-01

    Currently in America the biofuel ethanol is primarily being produced by the dry grind technique to obtain the starch contained in the corn grains and subsequently subjected to fermentation. This so-called 1st generation technology has two setbacks; first the lingering debate whether its life cycle

  3. utilization of bio fertilizers and organic sources in arable soils under saline conditions using tracer technique

    Salama, O.A.E.

    2011-01-01

    Recently, more attention has been paid to conserve and save surrounding environment via minimizing the excessive use of chemical fertilizers and, in general, the agrochemicals applied in heavy quantities in agricultural agroecosystems. Therefore, the attention of most of agronomists was turned towards the use of so called clean agriculture or organic farming. Many of organic systems was pointed out such as the recycling of farm wastes i.e. crop residues, animal manure, organic conditioners for reclamation of soil and in the same time enhancement of plant growth and improving yield quality. The application of organic wastes combined with or without microbial inoculants to plant media are considered as a good management practice in any agricultural production system because it improves, plant quality and soil fertility. Therefore, we have the opportunity to conduct some experiments for achieving the clean agriculture approach, combating the adverse effects of salinity and avoiding the environmental pollution. Series of laboratory and greenhouse experiments were carried out to evaluate the impact of (1) potent isolated fungi (Aspergillus oryzae and Aspergillus terreus) on degrading plant residues (Leucaena and Acacia green parts), and (2) biofertilizers (Sinorhizobium meliloti, Azospirillum brasilense, and Pseudomonas aeruginosa) in assessing barley and spinach plants to combat salinity of soil and irrigation water. 15 N-tracer technique that considered unique and more reliable technique may benefits in clarifying the responsible mechanisms related to plant growth and gave us the opportunity to quantify the exact amounts of N derived from the different sources of nitrogen available to spinach and barley plants grown on sandy saline soil and irrigated with saline water.

  4. Characterising the vertical separation of shale-gas source rocks and aquifers across England and Wales (UK)

    Loveless, Sian E.; Bloomfield, John P.; Ward, Robert S.; Hart, Alwyn J.; Davey, Ian R.; Lewis, Melinda A.

    2018-03-01

    Shale gas is considered by many to have the potential to provide the UK with greater energy security, economic growth and jobs. However, development of a shale gas industry is highly contentious due to environmental concerns including the risk of groundwater pollution. Evidence suggests that the vertical separation between exploited shale units and aquifers is an important factor in the risk to groundwater from shale gas exploitation. A methodology is presented to assess the vertical separation between different pairs of aquifers and shales that are present across England and Wales. The application of the method is then demonstrated for two of these pairs—the Cretaceous Chalk Group aquifer and the Upper Jurassic Kimmeridge Clay Formation, and the Triassic sandstone aquifer and the Carboniferous Bowland Shale Formation. Challenges in defining what might be considered criteria for `safe separation' between a shale gas formation and an overlying aquifer are discussed, in particular with respect to uncertainties in geological properties, aquifer extents and determination of socially acceptable risk levels. Modelled vertical separations suggest that the risk of aquifer contamination from shale exploration will vary greatly between shale-aquifer pairs and between regions and this will need to be considered carefully as part of the risk assessment and management for any shale gas development.

  5. In Search of the Sources of Psychologically Controlling Parenting: The Role of Parental Separation Anxiety and Parental Maladaptive Perfectionism

    Soenens, Bart; Vansteenkiste, Maarten; Duriez, Bart; Goossens, Luc

    2006-01-01

    This study investigated the role of two dimensions of parental separation anxiety--Anxiety about Adolescent Distancing (AAD) and Comfort with Secure Base Role (CSBR)--and parental maladaptive perfectionism in the prediction of psychologically controlling parenting. In a sample of middle adolescents and their parents (N=677), it was found that…

  6. Method and apparatus for separating isotopes

    Harris, S.E.

    1976-01-01

    Isotope separation is achieved between species A and B having an absorption resonance separated by an isotopic shift by selectively exciting a portion of species A using a tunable photon source of narrow emission line with and subsequently causing collisions with an optically excited third species to selectively ionize the excited portion of species A. When ionized, species A is easily separated by any technique, using its ionized condition to distinguish it from species B. 18 claims, 3 drawing figures

  7. Deciphering storm-event runoff behavior in a coastal plain watershed using chemical and physical hydrograph separation techniques

    Timothy Callahan; Austin E. Morrison

    2016-01-01

    Interpreting storm-event runoff in coastal plain watersheds is challenging because of the space- and time-variable nature of different sources that contribute to stream flow. These flow vectors and the magnitude of water flux is dependent on the pre-storm soil moisture (as estimated from depth to water table) in the lower coastal plain (LCP) region.

  8. Development of an Ionization Scheme for Gold using the Selective Laser Ion Source at the On-Line Isotope Separator ISOLDE

    Fedosseev, V; Marsh, B A; CERN. Geneva. AB Department

    2006-01-01

    At the ISOLDE on-line isotope separation facility, the resonance ionization laser ion source (RILIS) can be used to ionize reaction products as they effuse from the target. The RILIS process of laser step-wise resonance ionization of atoms in a hot metal cavity provides a highly element selective stage in the preparation of the radioactive ion beam. As a result, the ISOLDE mass separators can provide beams of a chosen isotope with greatly reduced isobaric contamination. The number of elements available at RILIS has been extended to 26, with the addition of a new three-step ionization scheme for gold. The optimal ionization scheme was determined during an extensive study of the atomic energy levels and auto-ionizing states of gold, carried out by means of in-source resonance ionization spectroscopy. Details of the ionization scheme and a summary of the spectroscopy study are presented.

  9. The low-frequency sound power measuring technique for an underwater source in a non-anechoic tank

    Zhang, Yi-Ming; Tang, Rui; Li, Qi; Shang, Da-Jing

    2018-03-01

    In order to determine the radiated sound power of an underwater source below the Schroeder cut-off frequency in a non-anechoic tank, a low-frequency extension measuring technique is proposed. This technique is based on a unique relationship between the transmission characteristics of the enclosed field and those of the free field, which can be obtained as a correction term based on previous measurements of a known simple source. The radiated sound power of an unknown underwater source in the free field can thereby be obtained accurately from measurements in a non-anechoic tank. To verify the validity of the proposed technique, a mathematical model of the enclosed field is established using normal-mode theory, and the relationship between the transmission characteristics of the enclosed and free fields is obtained. The radiated sound power of an underwater transducer source is tested in a glass tank using the proposed low-frequency extension measuring technique. Compared with the free field, the radiated sound power level of the narrowband spectrum deviation is found to be less than 3 dB, and the 1/3 octave spectrum deviation is found to be less than 1 dB. The proposed testing technique can be used not only to extend the low-frequency applications of non-anechoic tanks, but also for measurement of radiated sound power from complicated sources in non-anechoic tanks.

  10. Transport-level description of the 252Cf-source method using the Langevin technique

    Stolle, A.M.; Akcasu, A.Z.

    1991-01-01

    The fluctuations in the neutron number density and detector outputs in a nuclear reactor can be analyzed conveniently by using the Langevin equation approach. This approach can be implemented at any level of approximation to describe the time evolution of the neutron population, from the most complete transport-level description to the very basic point reactor analysis of neutron number density fluctuations. In this summary, the complete space- and velocity-dependent transport-level formulation of the Langevin equation approach is applied to the analysis of the 252 Cf-source-driven noise analysis (CSDNA) method, an experimental technique developed by J.T. Mihalczo at Oak Ridge National Laboratory, which makes use of noise analysis to determine the reactivity of subcritical media. From this analysis, a theoretical expression for the subcritical multiplication factor is obtained that can then be used to interpret the experimental data. Results at the transport level are in complete agreement with an independent derivation performed by Sutton and Doub, who used the probability density method to interpret the CSDNA experiment, but differed from other expressions that have appeared in the literature

  11. evaluation of selected composted organic sources on potato plant grown in sandy soil using nuclear technique

    Moursy, A.A.A.

    2008-01-01

    the main point of this study is the evaluation of organic compost as a source of nutrient demand by potatoes cultivated in light texture soil under drip irrigation system. the composted materials either applied alone or in combination with mineral fertilizer have an effective role on potato yields and nutrients management under field scale. so, many objectives were achieved. the valuable results obtained in the present study could be summarized as follows: part one: composting experiment contains ph changes of composted materials, EC changes with time, nitrogen content in composted materials, change of c/n ratio with time, organic matter content of the composted materials, phosphorus content in composted materials,. part two: potato field experiment contains .dry matter yield, tuber dry weight, tuber yield, nutrients uptake by potato varieties,. part three contains . application of 15 N isotope dilution technique, nitrogen derived from fertilizer (Ndff), nitrogen derived from organic compost (% Ndf comp),nitrogen derived from soil (% Ndfs), fertilizer use efficiency (% FUE), 15 N recovered by potatoes.

  12. Two-monoclonal-antibody sandwich-type assay for thyrotropin, with use of an avidin-biotin separation technique

    Odell, W.D.; Griffin, J.; Zahradnik, R.

    1986-01-01

    We have developed a sensitive, specific, noncompetitive, sandwich-type radioimmunoassay for human thyrotropin (hTSH), which can be performed in 30 min. The assay involves two monoclonal antibodies, selected for high affinity and specificity and also for reaction against antigenic sites on hTSH that are distal from each other. One of these antibodies is labeled with 125 I; the other is conjugated covalently to biotin. Polystyrene beads were also conjugated covalently to biotin. After conjugation, the beads were incubated with avidin. These beads represent a rapid, simple method for separating hTSH-bound antibody from free antibody. The biotin-antibody-hTSH- 125 I-labeled antibody complexes bind to the beads and hTSH concentration is directly related to counts per minute. This assay can detect hTSH at a concentration of 0.06 milli-unit/L in serum

  13. Connection experiments with a hollow cathode ion source and a helium gas jet system for on-line isotope separation

    Mazumdar, A.K.; Wagner, H.; Walcher, W.; Lund, T.

    1976-01-01

    A helium jet system was connected to a hollow cathode ion source. Using fission products the efficiencies of the different steps were measured by β-, X-ray and γ-counting while the mass spectrum and the focussing of the extracted ion beam were observed with a small deflecting magnet. Mean transport efficiencies of 50% through the 12 m capillary were obtained and ion source efficiencies in the percent range for several elements. (Auth.)

  14. A Novel Blind Source Separation Algorithm and Performance Analysis of Weak Signal against Strong Interference in Passive Radar Systems

    Chengjie Li

    2016-01-01

    Full Text Available In Passive Radar System, obtaining the mixed weak object signal against the super power signal (jamming is still a challenging task. In this paper, a novel framework based on Passive Radar System is designed for weak object signal separation. Firstly, we propose an Interference Cancellation algorithm (IC-algorithm to extract the mixed weak object signals from the strong jamming. Then, an improved FastICA algorithm with K-means cluster is designed to separate each weak signal from the mixed weak object signals. At last, we discuss the performance of the proposed method and verify the novel method based on several simulations. The experimental results demonstrate the effectiveness of the proposed method.

  15. Efficacy of Blood Sources and Artificial Blood Feeding Methods in Rearing of Aedes aegypti (Diptera: Culicidae) for Sterile Insect Technique and Incompatible Insect Technique Approaches in Sri Lanka.

    Gunathilaka, Nayana; Ranathunge, Tharaka; Udayanga, Lahiru; Abeyewickreme, Wimaladharma

    2017-01-01

    Selection of the artificial membrane feeding technique and blood meal source has been recognized as key considerations in mass rearing of vectors. Artificial membrane feeding techniques, namely, glass plate, metal plate, and Hemotek membrane feeding method, and three blood sources (human, cattle, and chicken) were evaluated based on feeding rates, fecundity, and hatching rates of Aedes aegypti . Significance in the variations among blood feeding was investigated by one-way ANOVA, cluster analysis of variance (ANOSIM), and principal coordinates (PCO) analysis. Feeding rates of Ae. aegypti significantly differed among the membrane feeding techniques as suggested by one-way ANOVA ( p feeding technique. Blood feeding rate of Ae. aegypti was higher with human blood followed by cattle and chicken blood, respectively. However, no significant difference was observed from the mosquitoes fed with cattle and human blood, in terms of fecundity, oviposition rate, and fertility as suggested by one-way ANOVA ( p > 0.05). Metal plate method could be recommended as the most effective membrane feeding technique for mass rearing of Ae. aegypti , due to its high feeding rate and cost effectiveness. Cattle blood could be recommended for mass rearing Ae. aegypti .

  16. Rapid detection of Escherichia coli and enterococci in recreational water using an immunomagnetic separation/adenosine triphosphate technique

    Bushon, R.N.; Brady, A.M.; Likirdopulos, C.A.; Cireddu, J.V.

    2009-01-01

    Aims: The aim of this study was to examine a rapid method for detecting Escherichia coli and enterococci in recreational water. Methods and Results: Water samples were assayed for E. coli and enterococci by traditional and immunomagnetic separation/adenosine triphosphate (IMS/ATP) methods. Three sample treatments were evaluated for the IMS/ATP method: double filtration, single filtration, and direct analysis. Pearson's correlation analysis showed strong, significant, linear relations between IMS/ATP and traditional methods for all sample treatments; strongest linear correlations were with the direct analysis (r = 0.62 and 0.77 for E. coli and enterococci, respectively). Additionally, simple linear regression was used to estimate bacteria concentrations as a function of IMS/ATP results. The correct classification of water-quality criteria was 67% for E. coli and 80% for enterococci. Conclusions: The IMS/ATP method is a viable alternative to traditional methods for faecal-indicator bacteria. Significance and Impact of the Study: The IMS/ATP method addresses critical public health needs for the rapid detection of faecal-indicator contamination and has potential for satisfying US legislative mandates requiring methods to detect bathing water contamination in 2 h or less. Moreover, IMS/ATP equipment is considerably less costly and more portable than that for molecular methods, making the method suitable for field applications. ?? 2009 The Authors.

  17. Investigations on extraction separation of noble metals from secondary raw materials by means of tracer technique application

    Urban'ski, T.S.; Migdal, V.; Lada, V.

    1979-01-01

    In laboratory scale equilibrium and kinetics of the liquid extraction of gold, platinum and palladium from chloride and nitrate-chloride solutions were investigated. Experiments were done using model solutions and solutions, obtained in processing of secondary raw materials, for example: solutions in aqua regia of anode slurries after electrical refining of silver and jewelry wastes, as well as solutions after extraction of silver from nitrate mwdia. In investigations for determination of the extraction factor, the radioisotope indicators method have been used. Gold-198, platinum-197, palladium-109, silver-110 m and copper-64 were used. Radioisotope platinum-197 was refined from gold-199 on the ionite Dauex 50VX2 in the medium of hydrobromic acid. Gold was extracted by neutral extraction agents such as tributilphosphate; methylizobutylketone; amylacetate; amil alcohol; 2-ethylhexanol and dibutylcarbitol. In details extraction of palladium and platinum by tri-n-actylamine in different diluents with additions of modifiers, as well as their extraction by aliquat 336 in benzene and by some petroleum products. Influence was determined of the time of phases contact, of application of diluents, influence of extracting agents concentrations on the magnitude of extraction factor and on the separation factor for investigated metals [ru

  18. Chromatographic separations of stereoisomers

    Souter, R.W.

    1985-01-01

    This text covers both diastereomers and enantiomers; describes techniques for GC, HPLC, and other chromatographic methods; and tabulates results of various applications by both techniques and compound class. It provides current knowledge about separation mechanisms and interactions of asymmetric molecules, as well as experimental and commercial materials such as columns, instruments, and derivatization reagents. The contents also include stereoisomer separations by gas chromatography. Stereoisomer separations by high-performance liquid chromatography. Stereoisomer separations by other chromatographic techniques.

  19. Scoping Study of Machine Learning Techniques for Visualization and Analysis of Multi-source Data in Nuclear Safeguards

    Cui, Yonggang

    2018-05-07

    In implementation of nuclear safeguards, many different techniques are being used to monitor operation of nuclear facilities and safeguard nuclear materials, ranging from radiation detectors, flow monitors, video surveillance, satellite imagers, digital seals to open source search and reports of onsite inspections/verifications. Each technique measures one or more unique properties related to nuclear materials or operation processes. Because these data sets have no or loose correlations, it could be beneficial to analyze the data sets together to improve the effectiveness and efficiency of safeguards processes. Advanced visualization techniques and machine-learning based multi-modality analysis could be effective tools in such integrated analysis. In this project, we will conduct a survey of existing visualization and analysis techniques for multi-source data and assess their potential values in nuclear safeguards.

  20. The characterisation of Melanesian obsidian sources and artefacts using the proton induced gamma-ray emission (PIGME) technique

    Bird, J.R.; Ambrose, W.R.; Russell, L.H.; Scott, M.D.

    1981-09-01

    Proton induced gamma-ray emission (PIGME) has been used to determine F, Na and Al concentrations in obsidian from known locations in Melanesia and to relate artefacts from this region to such sources. The PIGME technique is a fast, non-destructive, and accurate method for determining these three elements with essentially no special sample preparation. The measuring technique is described and results are listed for sources, chiefly in the Papua New Guinea region. Their classification is discussed in terms of groups which are distinguishable by the PIGME method. Over 700 artefact results are listed; these show the occurrence of an additional group that is not geographically identified

  1. Improved Tensor-Based Singular Spectrum Analysis Based on Single Channel Blind Source Separation Algorithm and Its Application to Fault Diagnosis

    Dan Yang

    2017-04-01

    Full Text Available To solve the problem of multi-fault blind source separation (BSS in the case that the observed signals are under-determined, a novel approach for single channel blind source separation (SCBSS based on the improved tensor-based singular spectrum analysis (TSSA is proposed. As the most natural representation of high-dimensional data, tensor can preserve the intrinsic structure of the data to the maximum extent. Thus, TSSA method can be employed to extract the multi-fault features from the measured single-channel vibration signal. However, SCBSS based on TSSA still has some limitations, mainly including unsatisfactory convergence of TSSA in many cases and the number of source signals is hard to accurately estimate. Therefore, the improved TSSA algorithm based on canonical decomposition and parallel factors (CANDECOMP/PARAFAC weighted optimization, namely CP-WOPT, is proposed in this paper. CP-WOPT algorithm is applied to process the factor matrix using a first-order optimization approach instead of the original least square method in TSSA, so as to improve the convergence of this algorithm. In order to accurately estimate the number of the source signals in BSS, EMD-SVD-BIC (empirical mode decomposition—singular value decomposition—Bayesian information criterion method, instead of the SVD in the conventional TSSA, is introduced. To validate the proposed method, we applied it to the analysis of the numerical simulation signal and the multi-fault rolling bearing signals.

  2. WE-G-18C-07: Accelerated Water/fat Separation in MRI for Radiotherapy Planning Using Multi-Band Imaging Techniques

    Crijns, S; Stemkens, B; Sbrizzi, A; Lagendijk, J; Berg, C van den; Andreychenko, A [UMC Utrecht, Utrecht, Utrecht (Netherlands)

    2014-06-15

    Purpose: Dixon sequences are used to characterize disease processes, obtain good fat or water separation in cases where fat suppression fails and to obtain pseudo-CT datasets. Dixon's method uses at least two images acquired with different echo times and thus requires prolonged acquisition times. To overcome associated problems (e.g., for DCE/cine-MRI), we propose to use a method for water/fat separation based on spectrally selective RF pulses. Methods: Two alternating RF pulses were used, that imposes a fat selective phase cycling over the phase encoding lines, which results in a spatial shift for fat in the reconstructed image, identical to that in CAIPIRINHA. Associated aliasing artefacts were resolved using the encoding power of a multi-element receiver array, analogous to SENSE. In vivo measurements were performed on a 1.5T clinical MR-scanner in a healthy volunteer's legs, using a four channel receiver coil. Gradient echo images were acquired with TE/TR = 2.3/4.7ms, flip angle 20°, FOV 45×22.5cm{sup 2}, matrix 480×216, slice thickness 5mm. Dixon images were acquired with TE,1/TE,2/TR=2.2/4.6/7ms. All image reconstructions were done in Matlab using the ReconFrame toolbox (Gyrotools, Zurich, CH). Results: RF pulse alternation yields a fat image offset from the water image. Hence the water and fat images fold over, which is resolved using in-plane SENSE reconstruction. Using the proposed technique, we achieved excellent water/fat separation comparable to Dixon images, while acquiring images at only one echo time. Conclusion: The proposed technique yields both inphase water and fat images at arbitrary echo times and requires only one measurement, thereby shortening the acquisition time by a factor 2. In future work the technique may be extended to a multi-band water/fat separation sequence that is able to achieve single point water/fat separation in multiple slices at once and hence yields higher speed-up factors.

  3. A new method for quantifying the performance of EEG blind source separation algorithms by referencing a simultaneously recorded ECoG signal.

    Oosugi, Naoya; Kitajo, Keiichi; Hasegawa, Naomi; Nagasaka, Yasuo; Okanoya, Kazuo; Fujii, Naotaka

    2017-09-01

    Blind source separation (BSS) algorithms extract neural signals from electroencephalography (EEG) data. However, it is difficult to quantify source separation performance because there is no criterion to dissociate neural signals and noise in EEG signals. This study develops a method for evaluating BSS performance. The idea is neural signals in EEG can be estimated by comparison with simultaneously measured electrocorticography (ECoG). Because the ECoG electrodes cover the majority of the lateral cortical surface and should capture most of the original neural sources in the EEG signals. We measured real EEG and ECoG data and developed an algorithm for evaluating BSS performance. First, EEG signals are separated into EEG components using the BSS algorithm. Second, the EEG components are ranked using the correlation coefficients of the ECoG regression and the components are grouped into subsets based on their ranks. Third, canonical correlation analysis estimates how much information is shared between the subsets of the EEG components and the ECoG signals. We used our algorithm to compare the performance of BSS algorithms (PCA, AMUSE, SOBI, JADE, fastICA) via the EEG and ECoG data of anesthetized nonhuman primates. The results (Best case >JADE = fastICA >AMUSE = SOBI ≥ PCA >random separation) were common to the two subjects. To encourage the further development of better BSS algorithms, our EEG and ECoG data are available on our Web site (http://neurotycho.org/) as a common testing platform. Copyright © 2017 The Author(s). Published by Elsevier Ltd.. All rights reserved.

  4. Theory and technique of spark source mass spectrometry; Theorie et technique de la spectrometrie de masse a etincelles

    Stefani, R [Commissariat a l' Energie Atomique, Grenoble (France). Centre d' Etudes Nucleaires

    1968-07-01

    Trace analysis in solids by spark source mass spectrometry involves complicated phenomena: element ionization in spark and blacking of sensitive emulsion by focused ion beam. However the principal risk of selectivity lies in analyser system, which realizes double focusing only for a part of the ions. Therefore, each analyst has to known ionic optics of his apparatus, for ensuring the transmission of mean energetic ions, which are representative of sample composition. By a careful photometry of mass spectrum, good reproducibility can be obtained. Thereafter accuracy depends on the knowledge of sensitivity coefficients proper to this apparatus. (author) [French] L'analyse de traces dans les solides par spectrometrie de masse a etincelles met en jeu des phenomenes complexes qui sont l'ionisation des elements dans l'etincelle, et le noircissement de l'emulsion sensible par les faisceaux ioniques focalises. Cependant, le risque majeur de selectivite provient de l'ensemble analyseur, qui realise la double focalisation sur une fraction seulement du faisceau d'ions. L'analyste doit donc connaitre en detail l'optique ionique de son appareil, pour assurer le passage de la bande d'energie moyenne des ions, qui seule caracterise quantitativement la composition chimique de l'echantillon. Une exploitation photometrique soignee du spectrogramme donne alors des resultats reproductibles, dont la justesse ne depend plus que des coefficients de sensibilite propres a ce type d'instrument. (auteur)

  5. Improvement in separation of isolated muons and pions at low pT in ATLAS hadron calorimeter using artificial neural networks technique

    Astvatsaturov, A.; Budagov, Yu.; Chirikov-Zorin, I.; Shigaev, V.; Paplevka, A.; Sushkov, S.; Bosman, M.; Nessi, M.

    1995-01-01

    Advantages of artificial neural networks techniques in handling data from highly granulated ATLAS hadron calorimeter (HC) are shown in application to isolated π/μ separation task in the range 3 T T muons have a significant probability to be absorbed in the calorimeter and therefore they cannot be reliably registered by the muon detector. The comparative analysis of main characteristics is presented for several neural net discriminators and a linear threshold discriminator operating on energy deposition in the last depth of HC. The analysis is based on MC data obtained with ATLAS simulation programs. 9 refs., 12 figs

  6. Separate collection of household food waste for anaerobic degradation – Comparison of different techniques from a systems perspective

    Bernstad, A.; Cour Jansen, J. la

    2012-01-01

    Highlight: ► Four modern and innovative systems for household food waste collection are compared. ► Direct emissions and resource use were based on full-scale data. ► Conservation of nutrients/energy content over the system was considered. ► Systems with high energy/nutrient recovery are most environmentally beneficial. - Abstract: Four systems for household food waste collection are compared in relation the environmental impact categories eutrophication potential, acidification potential, global warming potential as well as energy use. Also, a hotspot analysis is performed in order to suggest improvements in each of the compared collection systems. Separate collection of household food waste in paper bags (with and without drying prior to collection) with use of kitchen grinders and with use of vacuum system in kitchen sinks were compared. In all cases, food waste was used for anaerobic digestion with energy and nutrient recovery in all cases. Compared systems all resulted in net avoidance of assessed environmental impact categories; eutrophication potential (−0.1 to −2.4 kg NO 3 - eq/ton food waste), acidification potential (−0.4 to −1.0 kg SO 2 - eq/ton food waste), global warming potential (−790 to −960 kg CO 2 - eq/ton food waste) and primary energy use (−1.7 to −3.6 GJ/ton food waste). Collection with vacuum system results in the largest net avoidance of primary energy use, while disposal of food waste in paper bags for decentralized drying before collection result in a larger net avoidance of global warming, eutrophication and acidification. However, both these systems not have been taken into use in large scale systems yet and further investigations are needed in order to confirm the outcomes from the comparison. Ranking of scenarios differ largely if considering only emissions in the foreground system, indicating the importance of taking also downstream emissions into consideration when comparing different collection systems. The

  7. Staged abdominal closure with intramuscular tissue expanders and modified components separation technique of a giant incisional hernia after repair of a ruptured omphalocele

    Yukihiro Tatekawa

    2016-07-01

    Full Text Available In patients with omphalocele, several different techniques are performed for repair of the abdominal wall defect. We present the case of a staged abdominal closure of a giant incisional hernia after repair of a ruptured omphalocele. At birth, skin flap coverage associated with silo formation occurred, but the abdominal wall defect remained, resulting in a giant abdominal hernia. To expand the layers of the abdominal wall, tissue expanders were placed between the bilateral internal oblique and transverses abdominis muscles. Postoperatively, a modified components separation technique was performed. The abdominal wall was closed in the midline. Upon closure of the skin in the midline, bilateral relaxing incisions were performed, covering the remaining defect with artificial dermis. At the age of one year and 7 months, the patient had no recurrent incisional hernia nor any wound complications.

  8. Improved separability of dipole sources by tripolar versus conventional disk electrodes: a modeling study using independent component analysis.

    Cao, H; Besio, W; Jones, S; Medvedev, A

    2009-01-01

    Tripolar electrodes have been shown to have less mutual information and higher spatial resolution than disc electrodes. In this work, a four-layer anisotropic concentric spherical head computer model was programmed, then four configurations of time-varying dipole signals were used to generate the scalp surface signals that would be obtained with tripolar and disc electrodes, and four important EEG artifacts were tested: eye blinking, cheek movements, jaw movements, and talking. Finally, a fast fixed-point algorithm was used for signal independent component analysis (ICA). The results show that signals from tripolar electrodes generated better ICA separation results than from disc electrodes for EEG signals with these four types of artifacts.

  9. A Novel Partial Discharge Ultra-High Frequency Signal De-Noising Method Based on a Single-Channel Blind Source Separation Algorithm

    Liangliang Wei

    2018-02-01

    Full Text Available To effectively de-noise the Gaussian white noise and periodic narrow-band interference in the background noise of partial discharge ultra-high frequency (PD UHF signals in field tests, a novel de-noising method, based on a single-channel blind source separation algorithm, is proposed. Compared with traditional methods, the proposed method can effectively de-noise the noise interference, and the distortion of the de-noising PD signal is smaller. Firstly, the PD UHF signal is time-frequency analyzed by S-transform to obtain the number of source signals. Then, the single-channel detected PD signal is converted into multi-channel signals by singular value decomposition (SVD, and background noise is separated from multi-channel PD UHF signals by the joint approximate diagonalization of eigen-matrix method. At last, the source PD signal is estimated and recovered by the l1-norm minimization method. The proposed de-noising method was applied on the simulation test and field test detected signals, and the de-noising performance of the different methods was compared. The simulation and field test results demonstrate the effectiveness and correctness of the proposed method.

  10. A new technique for thick source alpha counting determination of U and Th

    Michael, C T

    2000-01-01

    A new technique for the calculation of U and Th concentration is presented based on the alpha particle spectrum taken from a thick sample by using a silicon detector. Four approaches to the analysis of the experimental data are presented, one being an improvement on the known pairs technique. By the proposed technique it is possible to calculate the concentrations of certain daughter nuclides in the two series, or the sum of the activity concentrations of others. This allows the detection of secular disequilibrium in our samples. This technique also has the advantage of being more accurate and provides the opportunity to cross-check the results derived from the different approaches.

  11. Modeling of the charge-state separation at ITEP experimental facility for material science based on a Bernas ion source.

    Barminova, H Y; Saratovskyh, M S

    2016-02-01

    The experiment automation system is supposed to be developed for experimental facility for material science at ITEP, based on a Bernas ion source. The program CAMFT is assumed to be involved into the program of the experiment automation. CAMFT is developed to simulate the intense charged particle bunch motion in the external magnetic fields with arbitrary geometry by means of the accurate solution of the particle motion equation. Program allows the consideration of the bunch intensity up to 10(10) ppb. Preliminary calculations are performed at ITEP supercomputer. The results of the simulation of the beam pre-acceleration and following turn in magnetic field are presented for different initial conditions.

  12. 'Blue bubble' technique: an ab interno approach for Descemet separation in deep anterior lamellar keratoplasty using trypan blue stained viscoelastic device.

    Livny, Eitan; Bahar, Irit; Hammel, Naama; Nahum, Yoav

    2018-04-01

    In this study, we examined a novel variant of 'big-bubble' deep anterior lamellar keratoplasty using trypan-blue-stained viscoelastic device for the creation of a pre-descemetic bubble. Ten corneoscleral rims were mounted on an artificial anterior chamber (AC). The AC was filled with air through a limbal paracentesis. A Melles' triangulated spatula was inserted through the paracentesis, with its tip penetrating the AC, was then slightly retracted and pushed into the deep stroma above the roof of the paracentesis. A mixture of trypan blue and viscoelastic device (Healon, Abbott Medical Optics, Abbott Park, Illinois) was injected into this intra-stromal pocket using a 27-G cannula to create a pre-descemetic separation bubble. Bubble type and visualization of dyed viscoelastic device were noted. The method was later employed in three cases. In all 10 corneoscleral rims, the technique successfully created a visible pre-descemetic (type 1) bubble that could be expanded up to the predicted diameter of trephination. Subsequent trephination and the removal of corneal stroma were uneventful. In two out of four clinical cases, a type 1 bubble was created, while in two others, visco-dissection failed and dyed viscoelastic was seen in the AC. The presented technique holds promise of being a relatively easy to perform, predictable and well-controlled alternative for achieving a type 1 bubble during deep anterior lamellar keratoplasty surgery. The trypan-blue-stained viscoelastic device facilitates proper visualization and control of the separation bubble and assists in identifying the penetrance to the separation bubble prior to removal of the stromal cap. © 2017 Royal Australian and New Zealand College of Ophthalmologists.

  13. Techniques and mechanisms applied in electron cyclotron resonance sources for highly charged ions

    Drentje, AG

    Electron cyclotron resonance ion sources are delivering beams of highly charged ions for a wide range of applications in many laboratories. For more than two decades, the development of these ion sources has been to a large extent an intuitive and experimental enterprise. Much effort has been spent

  14. Identification of sources of tar balls deposited along the Goa coast, India, using fingerprinting techniques

    Suneel, V.; Vethamony, P.; Zakaria, M.P.; Naik, B.G.; Prasad, K.V.S.R.

    2013-01-01

    Highlights: ► This is first fingerprinting study in India on identification of source of tar balls. ► Tar balls were formed from tanker-wash spills and they resemble floating tar ball. ► δ 13 C values of Bombay High crude oil and the present tar balls do not match. ► Compound specific stable carbon isotope analysis confirmed the source of tar balls. ► Source is confirmed as the South East Asian Crude Oil and not the Bombay High crude. -- Abstract: Deposition of tar balls along the coast of Goa, India is a common phenomenon during the southwest monsoon. Representative tar ball samples collected from various beaches of Goa and one Bombay High (BH) crude oil sample were subjected to fingerprint analysis based on diagnostic ratios of n-alkane, biomarkers of pentacyclic tri-terpanes and compound specific stable carbon isotope (δ 13 C) analysis to confirm the source. The results were compared with the published data of Middle East Crude Oil (MECO) and South East Asian Crude Oil (SEACO). The results revealed that the tar balls were from tanker-wash derived spills. The study also confirmed that the source is not the BH, but SEACO. The present study suggests that the biomarkers of alkanes and hopanes coupled with stable carbon isotope analysis act as a powerful tool for tracing the source of tar balls, particularly when the source specific biomarkers fail to distinguish the source

  15. Separation of fission produced 106Ru from simulated high level nuclear wastes for production of brachytherapy sources

    Blicharska, Magdalena; Bartoś, Barbara; Krajewski, Seweryn; Bilewicz, Aleksander

    2014-01-01

    Brachytherapy is the common method for treating various tumors, and currently 106 Ru and 125 I applicators are the most frequently used. Considering that 106 Ru is a β emitter with maximum energy of 3.54 MeV, it is best indicated in the treatment of small melanomas, with up to 20 mm tissue range. 106 Ru is commercially obtained from neutron irradiated high enrichment 235 U target in process of production 99 Mo. At present, there are only a handful of ageing reactors worldwide capable of producing the 99 Mo, therefore alternative strategies for production of this key medical isotope are explored. In our work, we propose to use liquid high-level radioactive waste as a source of high activity of 106 Ru. Simple calculations indicate that 1 dm 3 of HLLW solution after 4 years of cooling contains about 500 GBq of 106 Ru. This amount of activity is enough for production of about few thousands of brachytherapy sources. Present communication reports results of our process development studies on the recovery of ruthenium radioisotopes from simulated solution of high level radioactive waste using oxidation-extraction method

  16. Water quality assessment and apportionment of pollution sources using APCS-MLR and PMF receptor modeling techniques in three major rivers of South Florida.

    Haji Gholizadeh, Mohammad; Melesse, Assefa M; Reddi, Lakshmi

    2016-10-01

    In this study, principal component analysis (PCA), factor analysis (FA), and the absolute principal component score-multiple linear regression (APCS-MLR) receptor modeling technique were used to assess the water quality and identify and quantify the potential pollution sources affecting the water quality of three major rivers of South Florida. For this purpose, 15years (2000-2014) dataset of 12 water quality variables covering 16 monitoring stations, and approximately 35,000 observations was used. The PCA/FA method identified five and four potential pollution sources in wet and dry seasons, respectively, and the effective mechanisms, rules and causes were explained. The APCS-MLR apportioned their contributions to each water quality variable. Results showed that the point source pollution discharges from anthropogenic factors due to the discharge of agriculture waste and domestic and industrial wastewater were the major sources of river water contamination. Also, the studied variables were categorized into three groups of nutrients (total kjeldahl nitrogen, total phosphorus, total phosphate, and ammonia-N), water murkiness conducive parameters (total suspended solids, turbidity, and chlorophyll-a), and salt ions (magnesium, chloride, and sodium), and average contributions of different potential pollution sources to these categories were considered separately. The data matrix was also subjected to PMF receptor model using the EPA PMF-5.0 program and the two-way model described was performed for the PMF analyses. Comparison of the obtained results of PMF and APCS-MLR models showed that there were some significant differences in estimated contribution for each potential pollution source, especially in the wet season. Eventually, it was concluded that the APCS-MLR receptor modeling approach appears to be more physically plausible for the current study. It is believed that the results of apportionment could be very useful to the local authorities for the control and

  17. Tunable All Reflective Spatial Heterodyne Spectroscopy, A Technique For High Resolving Power Observation OI Defused Emission Line Sources

    Hosseini, Seyedeh Sona

    The solar system presents a challenge to spectroscopic observers, because it is an astrophysically low energy environment populated with often angularly extended targets (e.g, interplanetary medium, comets, planetary upper atmospheres, and planet and satellite near space environments). Spectroscopy is a proven tool for determining compositional and other properties of remote objects. Narrow band imaging and low resolving spectroscopic measurements provide information about composition, photochemical evolution, energy distribution and density. The extension to high resolving power provides further access to temperature, velocity, isotopic ratios, separation of blended sources, and opacity effects. The drawback of high-resolution spectroscopy comes from the instrumental limitations of lower throughput, the necessity of small entrance apertures, sensitivity, field of view, and large physical instrumental size. These limitations quickly become definitive for faint and/or extended targets and for spacecraft encounters. An emerging technique with promise for the study of faint, extended sources at high resolving power is the all-reflective form of the Spatial Heterodyne Spectrometer (SHS). SHS instruments are compact and naturally possess both high etendue and high resolving power. To achieve similar spectral grasp, grating spectrometers require big telescopes. SHS is a common-path beam Fourier transform interferometer that produces Fizeau fringe pattern for all other wavelengths except the tuned wavelength. Compared to similar Fourier transform Spectrometers (FTS), SHS has considerably relaxed optical tolerances that make it easier to use in the visible and UV spectral ranges. The large etendue of SHS instruments makes them ideal for observations of extended, low surface brightness, isolated emission line sources, while their intrinsically high spectral resolution enables the study of the dynamical and spectral characteristics described above. SHS also combines very

  18. Separation and capture of CO2 from large stationary sources and sequestration in geological formations--coalbeds and deep saline aquifers.

    White, Curt M; Strazisar, Brian R; Granite, Evan J; Hoffman, James S; Pennline, Henry W

    2003-06-01

    The topic of global warming as a result of increased atmospheric CO2 concentration is arguably the most important environmental issue that the world faces today. It is a global problem that will need to be solved on a global level. The link between anthropogenic emissions of CO2 with increased atmospheric CO2 levels and, in turn, with increased global temperatures has been well established and accepted by the world. International organizations such as the United Nations Framework Convention on Climate Change (UNFCCC) and the Intergovernmental Panel on Climate Change (IPCC) have been formed to address this issue. Three options are being explored to stabilize atmospheric levels of greenhouse gases (GHGs) and global temperatures without severely and negatively impacting standard of living: (1) increasing energy efficiency, (2) switching to less carbon-intensive sources of energy, and (3) carbon sequestration. To be successful, all three options must be used in concert. The third option is the subject of this review. Specifically, this review will cover the capture and geologic sequestration of CO2 generated from large point sources, namely fossil-fuel-fired power gasification plants. Sequestration of CO2 in geological formations is necessary to meet the President's Global Climate Change Initiative target of an 18% reduction in GHG intensity by 2012. Further, the best strategy to stabilize the atmospheric concentration of CO2 results from a multifaceted approach where sequestration of CO2 into geological formations is combined with increased efficiency in electric power generation and utilization, increased conservation, increased use of lower carbon-intensity fuels, and increased use of nuclear energy and renewables. This review covers the separation and capture of CO2 from both flue gas and fuel gas using wet scrubbing technologies, dry regenerable sorbents, membranes, cryogenics, pressure and temperature swing adsorption, and other advanced concepts. Existing

  19. Mass separation of rare-earth elements by a high-temperature thermal ion source coupled with a He-jet system

    Kawase, Y.; Okano, K.; Aoki, K.

    1987-01-01

    By using a high-temperature thermal ion source coupled to a He-jet system, neutron-rich isotopes of rare-earth elements such as cerium, praseodymium, neodymium and promethium produced by the thermal-neutron fission of /sup 235/U were ionized and successfully separated. The temperature dependence of the ionization efficiency has been measured and found to be explained qualitatively by the vapour pressure of the relevant elements. The characteristic temperature dependence of the ionization efficiency has been utilized for Z-identification of several isobars of rare-earth elements. The heaviest isotopes of neodymium and promethium, /sup 155/Nd and /sup 156/Pm, have recently been identified

  20. Techniques involved in the preparation of radioluminescent sources with promethium-147 and gaseous tritium radionuclides

    Seshadri, N.K.; Subramanian, T.K.; Ravi, S.; Mathew, K.M.; Chinnayan, C.

    2001-01-01

    Beta radiation emanating from promethium-147 and gaseous tritium in close proximity with zinc sulphide phosphor will provide self sustained light sources and are used for, nocturnal illumination of liquid crystal display digital watches and clocks, product advertisements, telephone numbers, exit signs etc. In this paper a procedure for activation of zinc sulphide phosphor with promethium-147 and development of gaseous tritium light sources with respect to thickness of phosphor coating and its effect on light output is described. A typical light source was constructed with promethium-147 activated zinc sulphide to find the overall efficiency of conversion of beta energy to visible light. (author)

  1. An effective dose assessment technique with NORM added consumer products using skin-point source on computational human phantom

    Yoo, Do Hyeon; Shin, Wook-Geun; Lee, Hyun Cheol; Choi, Hyun Joon; Testa, Mauro; Lee, Jae Kook; Yeom, Yeon Soo; Kim, Chan Hyeong; Min, Chul Hee

    2016-01-01

    The aim of this study is to develop the assessment technique of the effective dose by calculating the organ equivalent dose with a Monte Carlo (MC) simulation and a computational human phantom for the naturally occurring radioactive material (NORM) added consumer products. In this study, we suggests the method determining the MC source term based on the skin-point source enabling the convenient and conservative modeling of the various type of the products. To validate the skin-point source method, the organ equivalent doses were compared with that by the product modeling source of the realistic shape for the pillow, waist supporter, sleeping mattress etc. Our results show that according to the source location, the organ equivalent doses were observed as the similar tendency for both source determining methods, however, it was observed that the annual effective dose with the skin-point source was conservative than that with the modeling source with the maximum 3.3 times higher dose. With the assumption of the gamma energy of 1 MeV and product activity of 1 Bq g"−"1, the annual effective doses of the pillow, waist supporter and sleeping mattress with skin-point source was 3.09E-16 Sv Bq"−"1 year"−"1, 1.45E-15 Sv Bq"−"1 year"−"1, and 2,82E-16 Sv Bq"−"1 year"−"1, respectively, while the product modeling source showed 9.22E-17 Sv Bq"−"1 year"−"1, 9.29E-16 Sv Bq"−"1 year"−"1, and 8.83E-17 Sv Bq"−"1 year"−"1, respectively. In conclusion, it was demonstrated in this study that the skin-point source method could be employed to efficiently evaluate the annual effective dose due to the usage of the NORM added consumer products. - Highlights: • We evaluate the exposure dose from the usage of NORM added consumer products. • We suggest the method determining the MC source term based on the skin-point source. • To validate the skin-point source, the organ equivalent doses were compared with that the modeling source. • The skin-point source could

  2. Fate of PCBs, PAHs and their source characteristic ratios during composting and digestion of source-separated organic waste in full-scale plants

    Braendli, Rahel C.; Bucheli, Thomas D.; Kupper, Thomas; Mayer, Jochen; Stadelmann, Franz X.; Tarradellas, Joseph

    2007-01-01

    Composting and digestion are important waste management strategies. However, the resulting products can contain significant amounts of organic pollutants such as polychlorinated biphenyls (PCBs) and polycyclic aromatic hydrocarbons (PAHs). In this study we followed the concentration changes of PCBs and PAHs during composting and digestion on field-scale for the first time. Concentrations of low-chlorinated PCBs increased during composting (about 30%), whereas a slight decrease was observed for the higher chlorinated congeners (about 10%). Enantiomeric fractions of atropisomeric PCBs were essentially racemic and stable over time. Levels of low-molecular-weight PAHs declined during composting (50-90% reduction), whereas high-molecular-weight compounds were stable. The PCBs and PAHs concentrations did not seem to vary during digestion. Source apportionment by applying characteristic PAH ratios and molecular markers in input material did not give any clear results. Some of these parameters changed considerably during composting. Hence, their diagnostic potential for finished compost must be questioned. - During field-scale composting, low molecular weight PCBs and PAHs increased and decreased, respectively, whereas high molecular weight compounds remained stable

  3. Development of the high temperature ion-source for the Grenoble electromagnetic isotope separator; Etude et realisation de la source d'ions a haute temperature du separateur electromagnetique d'isotopes de Grenoble

    Bouriant, M [Commissariat a l' Energie Atomique, Grenoble (France). Centre d' Etudes Nucleaires

    1967-12-01

    The production of high purity stable or radioactive isotopes ({>=} 99.99 per cent) using electromagnetic separation require for equipment having a high resolving power. Besides, and in order to collect rare or short half-life isotopes, the efficiency of the ion-source must be high ({eta} > 5 to 10 per cent). With this in view, the source built operates at high temperatures (2500-3000 C) and makes use of ionisation by electronic bombardment or of thermo-ionisation. A summary is given in the first part of this work on the essential characteristics of the isotope separator ion Sources; a diagram of the principle of the source built is then given together with its characteristics. In the second part are given the values of the resolving power and of the efficiency of the Grenoble isotope separator fitted with such a source. The resolving power measured at 10 per cent of the peak height is of the order of 200. At the first magnetic stage the efficiency is between 1 and 26 per cent for a range of elements evaporating between 200 and 3000 C. Thus equipped, the separator has for example given, at the first stage, 10 mg of {sup 180}Hf at (99.69 {+-} 0.1) per cent corresponding to an enrichment coefficient of 580; recently 2 mg of {sup 150}Nd at (99.996 {+-} 0.002) per cent corresponding to an enrichment coefficient of 4.2 x 10{sup 5} has been obtained at the second stage. (author) [French] La production d'isotopes stables ou radioactifs de haute purete isotopique ({>=} 99.99 pour cent), par separation electromagnetique, exige des appareils de haut pouvoir de resolution. En outre, et en vue de collecter des isotopes de tres faible abondance ou de periode tres courte, le rendement des sources d'ions doit etre eleve ({eta} > 5 a 10 pour cent). Dans ce but, la source realisee fonctionne a haute temperature (2500-3000 C) et utilise l'ionisation par bombardement electronique, ou la thermoionisation. Dans la premiere partie de ce travail, on resume d'abord les caracteristiques

  4. Evaluation of Resonant Damping Techniques for Z-Source Current-Type Inverter

    Blaabjerg, Frede; Loh, Poh Chiang; Gajanayake, C.J.

    2008-01-01

    For the renewable energy sources whose outputs vary continuously, a Z-source current-type inverter has been proposed as a possible buck-boost alternative for grid-interfacing. With a unique X-shaped LC network connected between its dc power source and inverter topology, Z-source current......-type inverter is however expected to suffer from compounded resonant complications in addition to those associated with its second-order output filter. To improve its damping performance, this paper proposes the careful integration of Posicast or three-step compensators before the inverter pulse-width modulator...... for damping triggered resonant oscillations. In total, two compensators are needed for wave-shaping the inverter boost factor and modulation ratio, and they can conveniently be implemented using first-in first-out stacks and embedded timers of modern digital signal processors widely used in motion control...

  5. Investigation of natural phosphatidylcholine sources: separation and identification by liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS2) of molecular species.

    Le Grandois, Julie; Marchioni, Eric; Zhao, Minjie; Giuffrida, Francesca; Ennahar, Saïd; Bindler, Françoise

    2009-07-22

    This study is a contribution to the exploration of natural phospholipid (PL) sources rich in long-chain polyunsaturated fatty acids (LC-PUFAs) with nutritional interest. Phosphatidylcholines (PCs) were purified from total lipid extracts of different food matrices, and their molecular species were separated and identified by liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS(2)). Fragmentation of lithiated adducts allowed for the identification of fatty acids linked to the glycerol backbone. Soy PC was particularly rich in species containing essential fatty acids, such as (18:2-18:2)PC (34.0%), (16:0-18:2)PC (20.8%), and (18:1-18:2)PC (16.3%). PC from animal sources (ox liver and egg yolk) contained major molecular species, such as (16:0-18:2)PC, (16:0-18:1)PC, (18:0-18:2)PC, or (18:0-18:1)PC. Finally, marine source (krill oil), which was particularly rich in (16:0-20:5)PC and (16:0-22:6)PC, appeared to be an interesting potential source for food supplementation with LC-PUFA-PLs, particularly eicosapentaenoic acid (EPA) and docosahexaenoic acid (DHA).

  6. Galvanically Isolated Quasi-Z-Source DC–DC Converter With a Novel ZVS and ZCS Technique

    Husev, Oleksandr; Liivik, Liisa; Blaabjerg, Frede

    2015-01-01

    This paper focuses on the galvanically isolated quasi-Z-source dc-dc converter with a novel zero voltage and zero current switching technique. The unique feature of the impedance network lies in combining the buck-boost operation capability with the short- and open-circuit immunity of transistors......; at the same time, it can perform zero voltage and zero current switching on the primary side. The boundary conduction mode of the current in the second inductor of the quasi-Z-source network was used along with snubber capacitors in the two out of four transistors and a special control algorithm to achieve...

  7. Novel technique for addressing streak artifact in gated dual-source MDCT angiography utilizing ECG-editing

    Meyer, Laura T.; Boll, Daniel T. [Duke University Medical Center, Department of Radiology, Box 3808, Durham, NC (United States)

    2008-11-15

    Streak artifact is an important source of image degradation in computed tomographic imaging. In coronary MDCT angiography, streak artifact from pacemaker leads in the SVC can render segments of the right coronary artery uninterpretable. With current technology in clinical practice, there is no effective way to eliminate streak artifact in coronary MDCT angiography entirely. We propose a technique to minimize the impact of streak artifact in retrospectively gated coronary MDCT angiography by utilizing small shifts in the reconstruction window. In our experience, previously degraded portions of the coronary vasculature were able to be well evaluated using this technique. (orig.)

  8. Investigating Ammonia Emission Sources in a Coastal Urban Air Shed Using Stable Isotope Techniques

    Berner, A.; Felix, J. D. D.

    2017-12-01

    For nearly 100 years, mankind has met the food demands of a growing population by commercially producing and consuming reactive nitrogen fertilizers. So much so, that now 40-60% of the population relies on them. This increase has drastically altered the global nitrogen (N) cycle. Specifically, ammonia (NH3) emissions to the atmosphere have increased, resulting in wet and dry NHx (NH3 + NH4+) deposition products that can be substantial sources of N to sensitive ecosystems. Excess N can wreak havoc on these environments, causing soil acidification, water body eutrophication, and decreases in biodiversity. Despite these effects, NH3 remains generally unregulated in the U.S. Should policymakers elect to regulate NH3, quantification of NH3 emission sources and transport is essential. This has proven to be particularly difficult in urban regions, where ambient NH3 may result from local urban sources and/or NH3 transport from rural agricultural sources. The presented work investigates potential NH3 emission sources within a South Texas coastal urban air shed, Corpus Christi, TX, U.S.A. Previous work has shown an increasing fine particulate matter (PM2.5) trend within the region, which may be attributable to NH3 emissions from a variety of local sources, including vehicle traffic, shipping traffic, the petrochemical industry, and/or surrounding agricultural cropland and livestock. NH3 was collected monthly at a set of 8 sites within the Corpus Christi air shed, analyzed for NH3 concentration and N isotopic composition (d15N-NH3), and compared to known isotopic compositions of NH3 sources. Low and seasonally variable d15N-NH3 values are associated with varying agricultural sources (fertilizer, livestock waste, etc.), while higher and more seasonally constant d15N-NH3 values are associated with non-agricultural sources (vehicles, industry, etc.). Several other physical and chemical atmospheric components (e.g. SO2, NO2, O3, PM2.5, temperature, relative humidity) were also

  9. Identification of source of a marine oil-spill using geochemical and chemometric techniques

    Lobao, Marcio M.; Cardoso, Jari N.; Mello, Marcio R.; Brooks, Paul W.; Lopes, Claudio C.; Lopes, Rosangela S.C.

    2010-01-01

    Research highlights: → San Marcos bay (Maranhao, Brazil) contains small levels of petroleum hydrocarbons. → Oil pollution in San Marcos bay is low-level but chronic. → Aliphatic biomarkers were more useful for spill-oil source correlation in the area. - Abstract: The current work aimed to identify the source of an oil spill off the coast of Maranhao, Brazil, in September 2005 and effect a preliminary geochemical survey of this environment. A combination of bulk analytical parameters, such as carbon isotope (δ 13 C) and Ni/V ratios, and conventional fingerprinting methods (High Resolution Gas Chromatography and Mass Spectrometry) were used. The use of bulk methods greatly speeded source identification for this relatively unaltered spill: identification of the likely source was possible at this stage. Subsequent fingerprinting of biomarker distributions supported source assignment, pointing to a non-Brazilian oil. Steranes proved the most useful biomarkers for sample correlation in this work. Distribution patterns of environmentally more resilient compound types, such as certain aromatic structures, proved inconclusive for correlation, probably in view of their presence in the background.

  10. Errors and corrections in the separation of spin-flip and non-spin-flip thermal neutron scattering using the polarization analysis technique

    Williams, W.G.

    1975-01-01

    The use of the polarization analysis technique to separate spin-flip from non-spin-flip thermal neutron scattering is especially important in determining magnetic scattering cross-sections. In order to identify a spin-flip ratio in the scattering with a particular scattering process, it is necessary to correct the experimentally observed 'flipping-ratio' to allow for the efficiencies of the vital instrument components (polarizers and spin-flippers), as well as multiple scattering effects in the sample. Analytical expressions for these corections are presented and their magnitudes in typical cases estimated. The errors in measurement depend strongly on the uncertainties in the calibration of the efficiencies of the polarizers and the spin-flipper. The final section is devoted to a discussion of polarization analysis instruments

  11. Computational Analysis of Enhanced Circulating Tumour Cell (CTC Separation in a Microfluidic System with an Integrated Dielectrophoretic-Magnetophorectic (DEP-MAP Technique

    Wan Shi Low

    2016-08-01

    Full Text Available Cell based cancer analysis is an important analytic method to monitor cancer progress on stages by detecting the density of circulating tumour cells (CTCs in the blood. Among the existing microfluidic techniques, dielectrophoresis (DEP, which is a label-free detection method, is favoured by researchers. However, because of the high conductivity of blood as well as the rare presence of CTCs, high separation efficiency is difficult to achieve in most DEP microdevices. Through this study, we have proposed a strategy to improve the isolation performance, as such by integrating a magnetophoretic (MAP platform into a DEP device. Several important aspects to be taken into MAP design consideration, such as permanent magnet orientation, magnetic track configuration, fluid flow parameter and separation efficiency, are discussed. The design was examined and validated by numerical simulation using COMSOL Multiphysics v4.4 software (COMSOL Inc., Burlington, MA, USA, mainly presented in three forms: surface plot, line plot, and arrow plot. From these results, we showed that the use of a single permanent magnet coupled with an inbuilt magnetic track of 250 μm significantly strengthens the magnetic field distribution within the proposed MAP stage. Besides, in order to improve dynamic pressure without compromising the uniformity of fluid flow, a wide channel inlet and a tree-like network were employed. When the cell trajectory within a finalized MAP stage is computed with a particle tracing module, a high separation efficiency of red blood cell (RBC is obtained for blood samples corresponding up to a dilution ratio of 1:7. Moreover, a substantial enhancement of the CTCs’ recovery rate was also observed in the simulation when the purposed platform was integrated with a planar DEP microdevice.

  12. Source Evaluation and Trace Metal Contamination in Benthic Sediments from Equatorial Ecosystems Using Multivariate Statistical Techniques.

    Nsikak U Benson

    Full Text Available Trace metals (Cd, Cr, Cu, Ni and Pb concentrations in benthic sediments were analyzed through multi-step fractionation scheme to assess the levels and sources of contamination in estuarine, riverine and freshwater ecosystems in Niger Delta (Nigeria. The degree of contamination was assessed using the individual contamination factors (ICF and global contamination factor (GCF. Multivariate statistical approaches including principal component analysis (PCA, cluster analysis and correlation test were employed to evaluate the interrelationships and associated sources of contamination. The spatial distribution of metal concentrations followed the pattern Pb>Cu>Cr>Cd>Ni. Ecological risk index by ICF showed significant potential mobility and bioavailability for Cu, Cu and Ni. The ICF contamination trend in the benthic sediments at all studied sites was Cu>Cr>Ni>Cd>Pb. The principal component and agglomerative clustering analyses indicate that trace metals contamination in the ecosystems was influenced by multiple pollution sources.

  13. A study of some neutron-rich isotopes of lanthanum, cerium and praseodymium by means of fast chemical on-line separation technique SISAK

    Skarnemark, G.

    1977-01-01

    The fast on-line chemical separation technique SISAK has been utilized to study the decay properties of neutron-rich isotopes of La, Ce and Pr. The results include partial decay schemes and γ-ray intensity data for 14 min 143 La, 42 s 144 La, 25 s 145 La, 9 s 146 La, 3 min 145 Ce, 14 min 146 Ce, 56 s 147 Ce, 50 s 148 Ce, 12 min 147 Pr, 2 min 148 Pr, 3 min 149 Pr and 6 s 150 Pr. Half-lives and γ-ray energies are reported for the previously unknown nuclides 147 La (Tsub(1/2) = 2.2 s), 148 La (Tsub(1/2) approximately 1 s), 149 Ce (Tsub(1/2) = 5.7 s) and 150 Ce (Tsub(1/2) = 4.1 s). The nuclides were formed in thermal neutron-induced fission of 235 U. The fission products were transferred to the SISAK system via a gas jet recoil transportation (GJRT) system. The combination of the GJRT system with SISAK is discussed, as well as the chemical separation systems used for the isolation of La, Ce and Pr. The appendices I - IX contain previously published material which is included in the thesis. (Auth.)

  14. Characterization of the neutron sources storage pool of the Neutron Standards Laboratory, using Montecarlo Techniques

    Campo Blanco, X.

    2015-01-01

    The development of irradiation damage resistant materials is one of the most important open fields in the design of experimental facilities and conceptual nucleoelectric fusion plants. The Neutron Standards Laboratory aims to contribute to this development by allowing the neutron irradiation of materials in its calibration neutron sources storage pool. For this purposes, it is essential to characterize the pool itself in terms of neutron fluence and spectra due to the calibration neutron sources. In this work, the main features of this facility are presented and the characterization of the storage pool is carried out. Finally, an application is shown of the obtained results to the neutron irradiation of material.

  15. Study of heterogeneous multiplying and non-multiplying media by the neutron pulsed source technique

    Deniz, V.

    1969-01-01

    The pulsed neutron technique consists essentially in sending in the medium to be studied a short neutron pulse and in determining the asymptotic decay constant of the generated population. The variation of the decay constant as a function of the size of the medium allows the medium characteristics to be defined. This technique has been largely developed these last years and has been applied as well to moderator as to multiplying media, in most cases homogeneous ones. We considered of interest of apply this technique to lattices, to see if useful informations could be collected for lattice calculations. We present here a general theoretical study of the problem, and results and interpretation of a series of experiments made on graphite lattices. There is a good agreement for non-multiplying media. In the case of multiplying media, it is shown that the age value used until now in graphite lattices calculations is over-estimated by about 10 per cent [fr

  16. Sources

    Duffy, L.P.

    1991-01-01

    This paper discusses the sources of radiation in the narrow perspective of radioactivity and the even narrow perspective of those sources that concern environmental management and restoration activities at DOE facilities, as well as a few related sources. Sources of irritation, Sources of inflammatory jingoism, and Sources of information. First, the sources of irritation fall into three categories: No reliable scientific ombudsman to speak without bias and prejudice for the public good, Technical jargon with unclear definitions exists within the radioactive nomenclature, and Scientific community keeps a low-profile with regard to public information. The next area of personal concern are the sources of inflammation. This include such things as: Plutonium being described as the most dangerous substance known to man, The amount of plutonium required to make a bomb, Talk of transuranic waste containing plutonium and its health affects, TMI-2 and Chernobyl being described as Siamese twins, Inadequate information on low-level disposal sites and current regulatory requirements under 10 CFR 61, Enhanced engineered waste disposal not being presented to the public accurately. Numerous sources of disinformation regarding low level radiation high-level radiation, Elusive nature of the scientific community, The Federal and State Health Agencies resources to address comparative risk, and Regulatory agencies speaking out without the support of the scientific community

  17. Application of rotating disk electrode technique for the preparation of Np, Pu and Am α-sources

    Tsoupko-Sitnikov, V.; Dayras, F.; Sanoit, J. de; Filossofov, D.

    2000-01-01

    Method of electrodeposition on rotating disk cathode (RDE) is applied for preparation of Np, Pu and Am α-standards. Phenomenon of critical current density is experimentally observed which is in perfect accord with Hansen's theory of electrodeposition. Influence of deposit calcination regime on quality of α-sources is studied, and comparison is made of uniformity of deposits obtained in various deposition systems. Standards with energy resolution better than 9 keV can be reproducibly obtained by optimized RDE electrodeposition technique

  18. Rapid chemical separations

    Trautmann, N

    1976-01-01

    A survey is given on the progress of fast chemical separation procedures during the last few years. Fast, discontinuous separation techniques are illustrated by a procedure for niobium. The use of such techniques for the chemical characterization of the heaviest known elements is described. Other rapid separation methods from aqueous solutions are summarized. The application of the high speed liquid chromatography to the separation of chemically similar elements is outlined. The use of the gas jet recoil transport method for nuclear reaction products and its combination with a continuous solvent extraction technique and with a thermochromatographic separation is presented. Different separation methods in the gas phase are briefly discussed and the attachment of a thermochromatographic technique to an on-line mass separator is shown. (45 refs).

  19. CLASSIFICATION AND RANKING OF FERMI LAT GAMMA-RAY SOURCES FROM THE 3FGL CATALOG USING MACHINE LEARNING TECHNIQUES

    Saz Parkinson, P. M. [Department of Physics, The University of Hong Kong, Pokfulam Road, Hong Kong (China); Xu, H.; Yu, P. L. H. [Department of Statistics and Actuarial Science, The University of Hong Kong, Pokfulam Road, Hong Kong (China); Salvetti, D.; Marelli, M. [INAF—Istituto di Astrofisica Spaziale e Fisica Cosmica Milano, via E. Bassini 15, I-20133, Milano (Italy); Falcone, A. D. [Department of Astronomy and Astrophysics, The Pennsylvania State University, University Park, PA 16802 (United States)

    2016-03-20

    We apply a number of statistical and machine learning techniques to classify and rank gamma-ray sources from the Third Fermi Large Area Telescope Source Catalog (3FGL), according to their likelihood of falling into the two major classes of gamma-ray emitters: pulsars (PSR) or active galactic nuclei (AGNs). Using 1904 3FGL sources that have been identified/associated with AGNs (1738) and PSR (166), we train (using 70% of our sample) and test (using 30%) our algorithms and find that the best overall accuracy (>96%) is obtained with the Random Forest (RF) technique, while using a logistic regression (LR) algorithm results in only marginally lower accuracy. We apply the same techniques on a subsample of 142 known gamma-ray pulsars to classify them into two major subcategories: young (YNG) and millisecond pulsars (MSP). Once more, the RF algorithm has the best overall accuracy (∼90%), while a boosted LR analysis comes a close second. We apply our two best models (RF and LR) to the entire 3FGL catalog, providing predictions on the likely nature of unassociated sources, including the likely type of pulsar (YNG or MSP). We also use our predictions to shed light on the possible nature of some gamma-ray sources with known associations (e.g., binaries, supernova remnants/pulsar wind nebulae). Finally, we provide a list of plausible X-ray counterparts for some pulsar candidates, obtained using Swift, Chandra, and XMM. The results of our study will be of interest both for in-depth follow-up searches (e.g., pulsar) at various wavelengths and for broader population studies.

  20. CLASSIFICATION AND RANKING OF FERMI LAT GAMMA-RAY SOURCES FROM THE 3FGL CATALOG USING MACHINE LEARNING TECHNIQUES

    Saz Parkinson, P. M.; Xu, H.; Yu, P. L. H.; Salvetti, D.; Marelli, M.; Falcone, A. D.

    2016-01-01

    We apply a number of statistical and machine learning techniques to classify and rank gamma-ray sources from the Third Fermi Large Area Telescope Source Catalog (3FGL), according to their likelihood of falling into the two major classes of gamma-ray emitters: pulsars (PSR) or active galactic nuclei (AGNs). Using 1904 3FGL sources that have been identified/associated with AGNs (1738) and PSR (166), we train (using 70% of our sample) and test (using 30%) our algorithms and find that the best overall accuracy (>96%) is obtained with the Random Forest (RF) technique, while using a logistic regression (LR) algorithm results in only marginally lower accuracy. We apply the same techniques on a subsample of 142 known gamma-ray pulsars to classify them into two major subcategories: young (YNG) and millisecond pulsars (MSP). Once more, the RF algorithm has the best overall accuracy (∼90%), while a boosted LR analysis comes a close second. We apply our two best models (RF and LR) to the entire 3FGL catalog, providing predictions on the likely nature of unassociated sources, including the likely type of pulsar (YNG or MSP). We also use our predictions to shed light on the possible nature of some gamma-ray sources with known associations (e.g., binaries, supernova remnants/pulsar wind nebulae). Finally, we provide a list of plausible X-ray counterparts for some pulsar candidates, obtained using Swift, Chandra, and XMM. The results of our study will be of interest both for in-depth follow-up searches (e.g., pulsar) at various wavelengths and for broader population studies

  1. Application of just-in-time manufacturing techniques in radioactive source in well logging industry

    Atma Yudha Prawira

    2017-03-01

    Full Text Available Nuclear logging is one of major areas of logging development. This paper presents an empirical investigation to bring the drilling and completion of wells from an ill-defined art to a refined sci-ence by using radioactive source to “look and measure” such as formation type, formation dip, porosity, fluid type and numerous other important factors. The initial nuclear logging tools rec-ords the radiation emitted by formation as they were crossed by boreholes. Gamma radiation is used in well logging as it is powerful enough to penetrate the formation and steel casing. The ra-dioactive source is reusable so that after engineer finished the job the radioactive source is sent back to bunker. In this case inventory level of radioactive source is relatively high compared with monthly movement and the company must spend large amount of cost just for inventory. After calculating and averaging the monthly movement in 2014 and 2015, we detected a big pos-sibility to cut the inventory level to reduce the inventory cost.

  2. Tapping Into an Ancient Source. Isotope Hydrology Techniques to Help Manage Water Resources

    Kidambi, Misha

    2011-01-01

    The Water Resources Program at the IAEA uses a powerful tool, isotope hydrology, that aids in coping with water scarcity. IAEA scientists are convinced that if we understand how to manage water efficiently, there will be sufficient renewable and non-renewable water sources for meet global needs

  3. Source Identification in Structural Acoustics with an Inverse Frequency Response Function Technique

    Visser, Rene

    2002-01-01

    Inverse source identification based on acoustic measurements is essential for the investigation and understanding of sound fields generated by structural vibrations of various devices and machinery. Acoustic pressure measurements performed on a grid in the nearfield of a surface can be used to

  4. Modulation Technique for Four-Leg Voltage Source Inverter without a Look-Up Table

    Ebrahimzadeh, Esmaeil; Farhangi, Shahrokh; Iman-Eini, Hossein

    2016-01-01

    Three-dimensional space-vector modulation (3D SVM) has more popularity among the other modulation techniques of the four-leg inverter due to higher DC-link voltage utilisation. Sequencing schemes of the switching vectors in the 3D SVM are divided into Class I and II categories. Each of these clas...

  5. Determination of boron in water solution by an indirect neutron activation technique from a 241Am/Be source

    Sales, H.B.

    1981-08-01

    Boron content in water solutions has been analysed by Indirect Activation Technique a twin 241 Am/Be neutron source with a source strength of 9x10 6 n/seg. The boron concentration was inferred from the measurement of the activity induced in a vanadium flux monitor. The vanadium rod was located inside the boron solution in a standart geometrical set up with respect to the neutron source. Boron concentrations in the range of 100 to 1000 ppm were determined with an overall accuracy of about 2% during a total analysis time of about 20 minutes. Eventhough the analysis is not selective for boron yet due the rapid, simple and precise nature, it is proposed for the analysis of boron in the primary coolant circuit of Nuclear Power Plants of PWR type. (Author) [pt

  6. Preparation and characterization of alpha sources as standards in the actinides separation; Preparacion y caracterizacion de fuentes alfa como estandares en la separacion de actinidos

    Monroy G, F.; Escobar A, L.; Zepeda R, C. P.; Balcazar, M., E-mail: fabiola.monroy@inin.gob.mx [ININ, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico)

    2017-09-15

    The radioisotopes Am-243, Cm-244, Pu-242 and U-232 are used as radioactive tracers in the processes of separation and quantification of the radioisotopes of Am, Cm, Pu and U contained in radioactive and nuclear wastes, with the purpose of determining the efficiency of said processes. For this, in this work, alpha sources of Am-243, Cm-244, Pu-242 and U-232 standards were prepared by two methods: evaporation and electro-deposition, and they were analyzed by means of alpha spectrometry to verify the properties of these radioactive standards. The alpha sources prepared by electro-deposition were analyzed by Raman spectrometry to determine the chemical form in which the actinide was deposited; the good homogeneity in the distribution of the deposit was determined with solid nuclear trace detectors. The resolution of the alpha spectra obtained with surface barrier detectors of the standards is greater when deposited by electro-deposition. The FWHM of the alpha sources prepared by electro-deposition is always lower than that prepared by evaporation. Actinides are electrodeposited in the form of hydroxides and oxo compounds. (Author)

  7. CHANDRA OBSERVATIONS OF A 1.9 kpc SEPARATION DOUBLE X-RAY SOURCE IN A CANDIDATE DUAL ACTIVE GALACTIC NUCLEUS GALAXY AT z = 0.16

    Comerford, Julia M.; Pooley, David; Gerke, Brian F.; Madejski, Greg M.

    2011-01-01

    We report Chandra observations of a double X-ray source in the z = 0.1569 galaxy SDSS J171544.05+600835.7. The galaxy was initially identified as a dual active galactic nucleus (AGN) candidate based on the double-peaked [O III] λ5007 emission lines, with a line-of-sight velocity separation of 350 km s -1 , in its Sloan Digital Sky Survey spectrum. We used the Kast Spectrograph at Lick Observatory to obtain two long-slit spectra of the galaxy at two different position angles, which reveal that the two Type 2 AGN emission components have not only a velocity offset, but also a projected spatial offset of 1.9 h -1 70 kpc on the sky. Chandra/ACIS observations of two X-ray sources with the same spatial offset and orientation as the optical emission suggest that the galaxy most likely contains Compton-thick dual AGNs, although the observations could also be explained by AGN jets. Deeper X-ray observations that reveal Fe K lines, if present, would distinguish between the two scenarios. The observations of a double X-ray source in SDSS J171544.05+600835.7 are a proof of concept for a new, systematic detection method that selects promising dual AGN candidates from ground-based spectroscopy that exhibits both velocity and spatial offsets in the AGN emission features.

  8. Estimating photometric redshifts for X-ray sources in the X-ATLAS field using machine-learning techniques

    Mountrichas, G.; Corral, A.; Masoura, V. A.; Georgantopoulos, I.; Ruiz, A.; Georgakakis, A.; Carrera, F. J.; Fotopoulou, S.

    2017-12-01

    We present photometric redshifts for 1031 X-ray sources in the X-ATLAS field using the machine-learning technique TPZ. X-ATLAS covers 7.1 deg2 observed with XMM-Newton within the Science Demonstration Phase of the H-ATLAS field, making it one of the largest contiguous areas of the sky with both XMM-Newton and Herschel coverage. All of the sources have available SDSS photometry, while 810 additionally have mid-IR and/or near-IR photometry. A spectroscopic sample of 5157 sources primarily in the XMM/XXL field, but also from several X-ray surveys and the SDSS DR13 redshift catalogue, was used to train the algorithm. Our analysis reveals that the algorithm performs best when the sources are split, based on their optical morphology, into point-like and extended sources. Optical photometry alone is not enough to estimate accurate photometric redshifts, but the results greatly improve when at least mid-IR photometry is added in the training process. In particular, our measurements show that the estimated photometric redshifts for the X-ray sources of the training sample have a normalized absolute median deviation, nmad ≈ 0.06, and a percentage of outliers, η = 10-14%, depending upon whether the sources are extended or point like. Our final catalogue contains photometric redshifts for 933 out of the 1031 X-ray sources with a median redshift of 0.9. The table of the photometric redshifts is only available at the CDS via anonymous ftp to http://cdsarc.u-strasbg.fr (http://130.79.128.5) or via http://cdsarc.u-strasbg.fr/viz-bin/qcat?J/A+A/608/A39

  9. Acoustic emission non-destructive testing of structures using source location techniques.

    Beattie, Alan G.

    2013-09-01

    The technology of acoustic emission (AE) testing has been advanced and used at Sandia for the past 40 years. AE has been used on structures including pressure vessels, fire bottles, wind turbines, gas wells, nuclear weapons, and solar collectors. This monograph begins with background topics in acoustics and instrumentation and then focuses on current acoustic emission technology. It covers the overall design and system setups for a test, with a wind turbine blade as the object. Test analysis is discussed with an emphasis on source location. Three test examples are presented, two on experimental wind turbine blades and one on aircraft fire extinguisher bottles. Finally, the code for a FORTRAN source location program is given as an example of a working analysis program. Throughout the document, the stress is on actual testing of real structures, not on laboratory experiments.

  10. Powering embedded electronics for wind turbine monitoring using multi-source energy harvesting techniques

    Anton, S. R.; Taylor, S. G.; Raby, E. Y.; Farinholt, K. M.

    2013-03-01

    With a global interest in the development of clean, renewable energy, wind energy has seen steady growth over the past several years. Advances in wind turbine technology bring larger, more complex turbines and wind farms. An important issue in the development of these complex systems is the ability to monitor the state of each turbine in an effort to improve the efficiency and power generation. Wireless sensor nodes can be used to interrogate the current state and health of wind turbine structures; however, a drawback of most current wireless sensor technology is their reliance on batteries for power. Energy harvesting solutions present the ability to create autonomous power sources for small, low-power electronics through the scavenging of ambient energy; however, most conventional energy harvesting systems employ a single mode of energy conversion, and thus are highly susceptible to variations in the ambient energy. In this work, a multi-source energy harvesting system is developed to power embedded electronics for wind turbine applications in which energy can be scavenged simultaneously from several ambient energy sources. Field testing is performed on a full-size, residential scale wind turbine where both vibration and solar energy harvesting systems are utilized to power wireless sensing systems. Two wireless sensors are investigated, including the wireless impedance device (WID) sensor node, developed at Los Alamos National Laboratory (LANL), and an ultra-low power RF system-on-chip board that is the basis for an embedded wireless accelerometer node currently under development at LANL. Results indicate the ability of the multi-source harvester to successfully power both sensors.

  11. Measurement of thermal conductivity of uranium metal using transient plane source technique

    Subramanian, G.G.S.; Bapuji, T.; Panneerselvam, G.; Antony, M.P.; Nagarajan, K.

    2012-01-01

    Thermo physical properties of fuel, cladding and structural materials play a significant role in the reactor operation. Thermal conductivity is one of the most important physical properties of the fuel which determines the maximum linear heat rating of the fuel in a reactor. As part of this study, the thermal conductivity of uranium metal was measured using a transient plane source (TPS) by Hot-disc method

  12. An intense lithium ion beam source using vacuum baking and discharge cleaning techniques

    Moschella, J.J.; Kusse, B.R.; Longfellow, J.P.; Olson, J.C.

    1991-01-01

    We have developed a high-purity, intense, lithium ion beam source which operates at 500 kV and 120 A/cm 2 with pulse widths of 125 ns full width half maximum. The beams were generated using a lithium chloride anode in planar magnetically insulated geometry. We have found that the combination of vacuum baking of the anode at 250 degree C followed by the application of 100 W of pure argon, steady-state, glow discharge cleaning reduced the impurity concentration in the beam to approximately 10% (components other than chlorine or lithium were considered impurities). Although the impurities were low, the concentration of chlorine in the 1+ and 2+ charge states was significant (∼25%). The remaining 65% of the beam consisted of Li + ions. Without the special cleaning process, over half the beam particles were impurities. It was determined that these impurities entered the beam at the anode surface but came originally from material in the vacuum chamber. After the cleaning process, recontamination was observed to occur in approximately 6 min. This long recontamination time, which was much greater than the expected monolayer formation time, was attributed to the elevated temperature of the anode. We also compared the electrical characteristics of the beams produced by LiCl anodes to those generated by a standard polyethylene proton source. In contrast to the polyethylene anode, the LiCl source exhibited a higher impedance, produced beams of lower ion current efficiency and had longer turn on times

  13. Source identification of particulate matter in a semi-urban area of Malaysia using multivariate techniques.

    Wahid, N B A; Latif, M T; Suan, L S; Dominick, D; Sahani, M; Jaafar, S A; Mohd Tahir, N

    2014-03-01

    This study aims to determine the composition and sources of particulate matter with an aerodynamic diameter of 10 μm or less (PM10) in a semi-urban area. PM10 samples were collected using a high volume sampler. Heavy metals (Fe, Zn, Pb, Mn, Cu, Cd and Ni) and cations (Na(+), K(+), Ca(2+) and Mg(2+)) were detected using inductively coupled plasma mass spectrometry, while anions (SO4 (2-), NO3 (-), Cl(-) and F(-)) were analysed using Ion Chromatography. Principle component analysis and multiple linear regressions were used to identify the source apportionment of PM10. Results showed the average concentration of PM10 was 29.5 ± 5.1 μg/m(3). The heavy metals found were dominated by Fe, followed by Zn, Pb, Cu, Mn, Cd and Ni. Na(+) was the dominant cation, followed by Ca(2+), K(+) and Mg(2+), whereas SO4 (2-) was the dominant anion, followed by NO3 (-), Cl(-) and F(-). The main sources of PM10 were the Earth's crust/road dust, followed by vehicle emissions, industrial emissions/road activity, and construction/biomass burning.

  14. Probe beam deflection technique as acoustic emission directionality sensor with photoacoustic emission source.

    Barnes, Ronald A; Maswadi, Saher; Glickman, Randolph; Shadaram, Mehdi

    2014-01-20

    The goal of this paper is to demonstrate the unique capability of measuring the vector or angular information of propagating acoustic waves using an optical sensor. Acoustic waves were generated using photoacoustic interaction and detected by the probe beam deflection technique. Experiments and simulations were performed to study the interaction of acoustic emissions with an optical sensor in a coupling medium. The simulated results predict the probe beam and wavefront interaction and produced simulated signals that are verified by experiment.

  15. Survey of Techniques for Deep Web Source Selection and Surfacing the Hidden Web Content

    Khushboo Khurana; M.B. Chandak

    2016-01-01

    Large and continuously growing dynamic web content has created new opportunities for large-scale data analysis in the recent years. There is huge amount of information that the traditional web crawlers cannot access, since they use link analysis technique by which only the surface web can be accessed. Traditional search engine crawlers require the web pages to be linked to other pages via hyperlinks causing large amount of web data to be hidden from the crawlers. Enormous data is available in...

  16. Criticality calculations by source-collision iteration technique for cylindrical systems

    Sundaram, V.K.; Gopinath, D.V.

    1977-01-01

    A fast-converging iterative technique is presented which uses first collision probabilities developed for obtaining criticality parameters in two-region cylindrical systems with multigroup structure in energy of the neutrons. The space transmission matrix is obtained part analytically and part numerically through evaluation of a single-fold integral. Critical dimensions for condensed systems of uranium and plutonium computed using this method are presented and compared with published values

  17. Locating non-volcanic tremor along the San Andreas Fault using a multiple array source imaging technique

    Ryberg, T.; Haberland, C.H.; Fuis, G.S.; Ellsworth, W.L.; Shelly, D.R.

    2010-01-01

    Non-volcanic tremor (NVT) has been observed at several subduction zones and at the San Andreas Fault (SAF). Tremor locations are commonly derived by cross-correlating envelope-transformed seismic traces in combination with source-scanning techniques. Recently, they have also been located by using relative relocations with master events, that is low-frequency earthquakes that are part of the tremor; locations are derived by conventional traveltime-based methods. Here we present a method to locate the sources of NVT using an imaging approach for multiple array data. The performance of the method is checked with synthetic tests and the relocation of earthquakes. We also applied the method to tremor occurring near Cholame, California. A set of small-aperture arrays (i.e. an array consisting of arrays) installed around Cholame provided the data set for this study. We observed several tremor episodes and located tremor sources in the vicinity of SAF. During individual tremor episodes, we observed a systematic change of source location, indicating rapid migration of the tremor source along SAF. ?? 2010 The Authors Geophysical Journal International ?? 2010 RAS.

  18. sources

    Shu-Yin Chiang

    2002-01-01

    Full Text Available In this paper, we study the simplified models of the ATM (Asynchronous Transfer Mode multiplexer network with Bernoulli random traffic sources. Based on the model, the performance measures are analyzed by the different output service schemes.

  19. Vermicomposting of source-separated human faeces by Eisenia fetida: effect of stocking density on feed consumption rate, growth characteristics and vermicompost production.

    Yadav, Kunwar D; Tare, Vinod; Ahammed, M Mansoor

    2011-06-01

    The main objective of the present study was to determine the optimum stocking density for feed consumption rate, biomass growth and reproduction of earthworm Eisenia fetida as well as determining and characterising vermicompost quantity and product, respectively, during vermicomposting of source-separated human faeces. For this, a number of experiments spanning up to 3 months were conducted using soil and vermicompost as support materials. Stocking density in the range of 0.25-5.00 kg/m(2) was employed in different tests. The results showed that 0.40-0.45 kg-feed/kg-worm/day was the maximum feed consumption rate by E. fetida in human faeces. The optimum stocking densities were 3.00 kg/m(2) for bioconversion of human faeces to vermicompost, and 0.50 kg/m(2) for earthworm biomass growth and reproduction. Copyright © 2011 Elsevier Ltd. All rights reserved.

  20. Hacking web intelligence open source intelligence and web reconnaissance concepts and techniques

    Chauhan, Sudhanshu

    2015-01-01

    Open source intelligence (OSINT) and web reconnaissance are rich topics for infosec professionals looking for the best ways to sift through the abundance of information widely available online. In many cases, the first stage of any security assessment-that is, reconnaissance-is not given enough attention by security professionals, hackers, and penetration testers. Often, the information openly present is as critical as the confidential data. Hacking Web Intelligence shows you how to dig into the Web and uncover the information many don't even know exists. The book takes a holistic approach