WorldWideScience

Sample records for source control practices

  1. Regulated control of practices and radiation sources

    International Nuclear Information System (INIS)

    1992-01-01

    Excepting the radiation caused by the natural background radiation, the Executive Secretariat for Nuclear Affairs (SEAN) does not authorize any source no practice within the national territory that may imply exposure of a person to ionizing radiation unless this use is ruled. This document establishes the basic criteria to set up such system as well as to exclude or exempt practices and sources from this regulated control

  2. Exemption of radiation sources and practices from regulatory control: Interim report

    International Nuclear Information System (INIS)

    1987-01-01

    This document is an interim report on progress at the IAEA on exemption principles and their application to low-level radioactive waste disposal. In the first part of the document the general principles for the exemption of radiation sources and practices from regulatory control are described. The exempt quantities of low-level radioactive wastes for disposal to municipal landfill or by incineration including methods for their derivation and generic values are contained in the second part of the document. In the appendices the individual effective dose equivalents and committed effective dose equivalents by pathway for waste concentrations of 1 Bq.g -1 and some quoted limits from the literature on dust concentrations at the outlet of municipal waste incinerators are estimated

  3. [A landscape ecological approach for urban non-point source pollution control].

    Science.gov (United States)

    Guo, Qinghai; Ma, Keming; Zhao, Jingzhu; Yang, Liu; Yin, Chengqing

    2005-05-01

    Urban non-point source pollution is a new problem appeared with the speeding development of urbanization. The particularity of urban land use and the increase of impervious surface area make urban non-point source pollution differ from agricultural non-point source pollution, and more difficult to control. Best Management Practices (BMPs) are the effective practices commonly applied in controlling urban non-point source pollution, mainly adopting local repairing practices to control the pollutants in surface runoff. Because of the close relationship between urban land use patterns and non-point source pollution, it would be rational to combine the landscape ecological planning with local BMPs to control the urban non-point source pollution, which needs, firstly, analyzing and evaluating the influence of landscape structure on water-bodies, pollution sources and pollutant removal processes to define the relationships between landscape spatial pattern and non-point source pollution and to decide the key polluted fields, and secondly, adjusting inherent landscape structures or/and joining new landscape factors to form new landscape pattern, and combining landscape planning and management through applying BMPs into planning to improve urban landscape heterogeneity and to control urban non-point source pollution.

  4. Urban stormwater source control policies: why and how?

    Directory of Open Access Journals (Sweden)

    G. Petrucci

    2014-09-01

    Full Text Available Stormwater source control is becoming a common strategy for urban stormwater management in many countries. It relies on regulations or other policy instruments compelling or inciting implementation, for each new urban development, of small-scale facilities to locally store and manage stormwater. Local authorities that pioneered source control since the 1980s have already observed that small-scale facilities systematically implemented over a catchment are able to influence its hydrological behaviour. This capability is the main strength of source control, as it allows compensation for the negative effects of urbanization. Yet, it also represents its main risk: if initial decision-making is not sufficiently accurate, source control can produce long-term negative effects. Because of its current spreading, source control will acquire an increasing role as a driver of hydrological changes in urban catchments, and the directions of these changes depend on current policy-making practices. This paper presents an analysis and a critical discussion of the main objectives that policy-makers attribute to stormwater source control. The investigation is based on a sample of French case studies, completed by a literature review for international comparison. It identifies four main objectives, some typical of urban stormwater management and some more innovative: flood reduction, receiving waters protection, sustainable development, costs reduction. The discussion focuses on how current policy-making practices are able to translate these objectives in concrete policy instruments, and on which knowledge and tools could improve this process. It is shown that for some objectives, basic knowledge is available, but the creation of policy instruments which are effective at the catchment scale and adapted to local conditions is still problematic. For other objectives, substantial lacks of knowledge exist, casting doubts on long-term effectiveness of current policy

  5. Patient experience of source isolation: lessons for clinical practice.

    Science.gov (United States)

    Barratt, Ruth Linda; Shaban, Ramon; Moyle, Wendy

    2011-10-01

    Methicillin-resistant Staphylococcus aureus (MRSA) is now the leading antimicrobial-resistant organism of concern to clinicians worldwide. Preventing and controlling the increase and spread of MRSA within the health-care environment is therefore an important function of the infection control team. The prevention and control of MRSA requires strict use of both Standard and Additional Precautions, which include good hand hygiene practices, judicious antimicrobial prescribing, and source isolation. While few would dispute the need for these precautions for preventing the spread of MRSA and other infections, their use may result in adverse physical and psychological effects for the patient. In an age of quality and safety of health care, ensuring infection control practice such as source isolation and contact precautions adhere to fundamental human rights is paramount. This paper presents a review of the literature on the patient experience of source isolation for MRSA or other infectious diseases. The review yielded five major interconnected themes: (1) psychological effects of isolation; (2) coping with isolation; (3) social isolation; (4) communication and information provision; and (5) physical environment and quality of care. It found that the experience of isolation by patients has both negative and positive elements. Isolation may result in detrimental psychological effects including anxiety, stress and depression, but may also result in the patient receiving less or substandard care. However, patients may also benefit from the quietness and privacy of single rooms. Nurses and other healthcare workers must look for ways to improve the experience of isolation and contact precautions of patients in source isolation. Opportunities exist in particular in improving the environment and the patient's self-control of the situation and in providing adequate information.

  6. Strengthening control over radioactive sources in authorized use and regaining control over orphan sources. National strategies

    International Nuclear Information System (INIS)

    2004-02-01

    The objective of this report is to provide practical guidance to States on the development of a national strategy for improving control over radioactive sources, particularly dangerous sources (Categories 1-3). Part of this process involves the determination of the magnitude of the potential problem with orphan and vulnerable sources and indeed, whether or not a national strategy is needed. The ultimate objective is that States will use this report to develop and then implement a plan of action that will result in all significant sources being managed in a safe and secure manner. This report attempts to provide both the background knowledge and the methodology necessary for an individual or small team of responsible persons to develop a national strategy for improving control over all radioactive sources, but especially orphan and vulnerable sources. The background knowledge given in Chapter 3 is an update of the information on practices that was given in IAEA-TECDOC-804, which focused on spent radioactive sources. After some introductory material, this report provides both the factual information and the general steps needed to develop and implement a national strategy. Part I contains background information for those who are not already familiar with the subject including the need for national strategies, the generic causes of loss of control of sources, with specific examples and the common applications of radioactive sources. Part II details the actual process for the development and implementation of a national strategy, which includes assessing the problem by first gathering specific and national information, determining the nature and magnitude of the problem, developing the national strategy by evaluating, and prioritizing possible solutions, implementing the strategy subsequent to a high level decision; and evaluating the effectiveness of the plan and making changes as a result until the desired objective is achieved. Searches for sources will be part of

  7. Regulatory inspection: a powerful tool to control industrial radioactive sources

    International Nuclear Information System (INIS)

    Silva, F.C.A. da; Leocadio, J.C.; Ramalho, A.T.

    2008-01-01

    An important contribution for Brazilian development, especially for the quality control of products, is the use of radiation sources by conventional industries. There are in Brazil roughly 3,000 radioactive sources spread out among 950 industries. The main industrial practices involved are: industrial radiography, industrial irradiators, industrial accelerators, well logging petroleum and nuclear gauges. More than 1,800 Radiation Protection Officers (RPOs) were qualified to work in these practices. The present work presents a brief description of the safety control over industrial radioactive installations performed by the Brazilian Regulatory Authority, i.e. the National Commission of Nuclear Energy (CNEN). This paper also describes the national system for radiation safety inspections, the regulation infrastructure and the national inventory of industrial installations. The inspections are based on specific indicators, and their periodicity depends on the risk and type of installation. The present work discusses some relevant aspects that must be considered during the inspections, in order to make the inspections more efficient in controlling the sources. One of these aspects regards the evaluation of the storage place for the sources, a very important parameter for preventing future risky situations. (author)

  8. Practical open source software for libraries

    CERN Document Server

    Engard, Nicole

    2010-01-01

    Open source refers to an application whose source code is made available for use or modification as users see fit. This means libraries gain more flexibility and freedom than with software purchased with license restrictions. Both the open source community and the library world live by the same rules and principles. Practical Open Source Software for Libraries explains the facts and dispels myths about open source. Chapters introduce librarians to open source and what it means for libraries. The reader is provided with links to a toolbox full of freely available open source products to use in

  9. Code of practice for the control and safe handling of radioactive sources used for therapeutic purposes (1988)

    International Nuclear Information System (INIS)

    1988-01-01

    This Code is intended as a guide to safe practices in the use of sealed and unsealed radioactive sources and in the management of patients being treated with them. It covers the procedures for the handling, preparation and use of radioactive sources, precautions to be taken for patients undergoing treatment, storage and transport of radioactive sources within a hospital or clinic, and routine testing of sealed sources [fr

  10. Optimizing best management practices to control anthropogenic sources of atmospheric phosphorus deposition to inland lakes.

    Science.gov (United States)

    Weiss, Lee; Thé, Jesse; Winter, Jennifer; Gharabaghi, Bahram

    2018-04-18

    Excessive phosphorus loading to inland freshwater lakes around the globe has resulted in nuisance plant growth along the waterfronts, degraded habitat for cold water fisheries, and impaired beaches, marinas and waterfront property. The direct atmospheric deposition of phosphorus can be a significant contributing source to inland lakes. The atmospheric deposition monitoring program for Lake Simcoe, Ontario indicates roughly 20% of the annual total phosphorus load (2010-2014 period) is due to direct atmospheric deposition (both wet and dry deposition) on the lake. This novel study presents a first-time application of the Genetic Algorithm (GA) methodology to optimize the application of best management practices (BMPs) related to agriculture and mobile sources to achieve atmospheric phosphorus reduction targets and restore the ecological health of the lake. The novel methodology takes into account the spatial distribution of the emission sources in the airshed, the complex atmospheric long-range transport and deposition processes, cost and efficiency of the popular management practices and social constraints related to the adoption of BMPs. The optimization scenarios suggest that the optimal overall capital investment of approximately $2M, $4M, and $10M annually can achieve roughly 3, 4 and 5 tonnes reduction in atmospheric P load to the lake, respectively. The exponential trend indicates diminishing returns for the investment beyond roughly $3M per year and that focussing much of this investment in the upwind, nearshore area will significantly impact deposition to the lake. The optimization is based on a combination of the lowest-cost, most-beneficial and socially-acceptable management practices that develops a science-informed promotion of implementation/BMP adoption strategy. The geospatial aspect to the optimization (i.e. proximity and location with respect to the lake) will help land managers to encourage the use of these targeted best practices in areas that

  11. Health physics source document for codes of practice

    International Nuclear Information System (INIS)

    Pearson, G.W.; Meggitt, G.C.

    1989-05-01

    Personnel preparing codes of practice often require basic Health Physics information or advice relating to radiological protection problems and this document is written primarily to supply such information. Certain technical terms used in the text are explained in the extensive glossary. Due to the pace of change in the field of radiological protection it is difficult to produce an up-to-date document. This document was compiled during 1988 however, and therefore contains the principle changes brought about by the introduction of the Ionising Radiations Regulations (1985). The paper covers the nature of ionising radiation, its biological effects and the principles of control. It is hoped that the document will provide a useful source of information for both codes of practice and wider areas and stimulate readers to study radiological protection issues in greater depth. (author)

  12. Sources of practice knowledge among Australian fitness trainers.

    Science.gov (United States)

    Bennie, Jason A; Wiesner, Glen H; van Uffelen, Jannique G Z; Harvey, Jack T; Biddle, Stuart J H

    2017-12-01

    Few studies have examined the sources of practice knowledge fitness trainers use to inform their training methods and update knowledge. This study aims to describe sources of practice knowledge among Australian fitness trainers. In July 2014, 9100 Australian fitness trainers were invited to complete an online survey. Respondents reported the frequency of use of eight sources of practice knowledge (e.g. fitness magazines, academic texts). In a separate survey, exercise science experts (n = 27) ranked each source as either (1) 'high-quality' or (2) 'low-quality'. Proportions of users of 'high-quality' sources were calculated across demographic (age, sex) and fitness industry-related characteristics (qualification, setting, role). A multivariate logistic regression analysis assessed the odds of being classified as a user of high-quality sources, adjusting for demographic and fitness industry-related factors. Out of 1185 fitness trainers (response rate = 13.0%), aged 17-72 years, 47.6% (95% CI, 44.7-50.4%) were classified as frequent users of high-quality sources of practice knowledge. In the adjusted analysis, compared to trainers aged 17-26 years, those aged ≥61 years (OR, 2.15; 95% CI, 1.05-4.38) and 40-50 years (OR, 1.54; 95% CI, 1.02-2.31) were more likely to be classified as a user of high-quality sources. When compared to trainers working in large centres, those working in outdoor settings (OR, 1.81; 95% CI, 1.23-2.65) and medium centres (OR, 1.59; 95% CI, 1.12-2.29) were more likely to be classified as users of high-quality sources. Our findings suggest that efforts should be made to improve the quality of knowledge acquisition among Australian fitness trainers.

  13. Principles for the exemption of radiation sources and practices from regulatory control

    International Nuclear Information System (INIS)

    1988-01-01

    Radiation sources, including equipment and installations, which emit ionizing radiations, are potentially harmful to health and their use should therefore be regulated. Some types of radiation source, however, do not need to be subject to regulatory control, because they present such a low hazard that it would be a needless waste of time and effort to exercise control by a regulatory process and they can therefore be exempted from it. An Advisory Group Meeting was convened in Vienna in March 1988 sponsored jointly by the IAEA and NEA. This Safety Guide is the result of that meeting and represents a first international consensus on the subject of exemption principles. This document is issued as an IAEA Safety Guide since it recommends a procedure which might be followed in implementing the Basic Safety Standards (BSS) for Radiation Protection. Its purpose is to recommend a policy on exemptions from the BSS system of notification, registration and licensing. 15 refs

  14. Categorisation of Practices and Sources- A Key Issue in Licensing Process

    International Nuclear Information System (INIS)

    Janzekovic, H.; Krizman, M.; Vokal, B.; Petrovic, Z.

    2004-01-01

    The analysis of a radioactive sources inventory in countries with a nuclear programme usually comprises nearly all possible man-made sources available today, from sources related to nuclear power plants to calibration sources used for educational purposes. The risk based licensing process of radiation sources and exposures is a demanding task which could be internationally harmonised by introducing sources and practice related categorisation. The detailed categorisation of radioisotopes, replacing [1], was recently published [2]. The activity ratio (A/D ratio) is used as a basic parameter which is proportional to a risk involved in a use of a radioisotope. Radioisotopes as well as related practices are categorised. No categorisation of ionising sources related to electrical apparatus producing ionising radiation without radioisotopes has been given in literature. In addition, licensees usually perform many different activities with a specific source, so the categorisation of practice should be done, based on a risk involved with a specific practice. The risk is related to the probability of a specific event as well as to the consequences of that event. It is strongly related to the categorisation of source. The main issues related to a licensing process of sources and practices are presented. The review of possible categorisation of radioisotopes and related practices is given and a proposal of a combined harmonised approach of categorisation of sources and practices, based on risk, is given. (Author) 19 refs

  15. Control of radioactive sources in industry through regulatory inspections

    International Nuclear Information System (INIS)

    Leocadio, J.C.; Ramalho, A.T.; Pinho, A.S.; Lourenco, M.M.J.; Nicola, M.S.; D'Avila, R.L.; Melo, I.F.; Cucco, A.C.S.

    2005-01-01

    In Brazil, the applications of ionizing radiation in industry are accomplished about 900 radioactive facilities, which handle approximately 3.000 radiation sources. The control of radioactive sources used in industrial installations authorized by the Brazilian Nuclear Energy Commission (CNEN) is accomplished by Servico de Radioprotecao na Industria Radiativa (SERIR) of the Instituto de Radioprotecao e Dosimetria (IRD), Rio de Janeiro, RJ, Brazil. This service carries out regulatory inspections in the practices of industrial radiography, nuclear gauges, industrial irradiators and oil wells logging. The frequency of inspections depends on the type of practice, ranging from a year to 5 years, depending on the risk involved. This paper presents a brief description of the situation of radiation safety in the use of radioactive sources in the industries of the country. The results obtained with regulatory inspections at industrial installations demonstrate that the conditions of safety and radiation protection in these facilities are satisfactory when compared with the technical regulations, both national and international

  16. Regulatory control and safety of radiation and radioactive sources in Bangladesh

    International Nuclear Information System (INIS)

    Mollah, A.S.

    2001-01-01

    The application of ionizing radiation and radioactive sources in different fields such as, medicine, industry, agriculture, research and teaching is constantly increasing in Bangladesh. Any system enacted to control exposure to ionizing radiation has as primary objective the protection of health of people against the deleterious effects of radiation. Establishing the appropriate level of radiological protection and safety of radiation sources used in practice or intervention attains this objective. The regulatory program governing the safe use of radioactive and radiation sources in Bangladesh is based on the legislation enacted as Nuclear Safety and Radiation Control (NSRC) Act-93 and NSRC Rules-97 and its implementation by the competent authority. The radiation control infrastructures and procedure are described as well as their functioning for the implementation of relevant activities such as licensing, regular inspection, personal dose monitoring, emergency preparedness, etc. The issue of security of radiation source is dealt in close relation with the preparation and use of the inventory of all radiation sources in the country

  17. Practical methods for exposure control/management at nuclear facilities

    International Nuclear Information System (INIS)

    Twiggs, J.A.

    1991-01-01

    Exposure management/reduction is very important to Duke Power Company. Practical exposure control/reduction techniques applied to their reactor vessel head disassembly outage activity have consistently reduced personnel exposure for this task. The following exposure control methods have worked for use and will be the industry's direction for the 1990's. A summary of these methods includes: (a) move the responsibility of exposure management from the Radiation Protection group to the Maintenance group; (b) reduce area source term by removal of source; (c) improve working environments in radiation areas by minimizing protective clothing usage; and (d) maximize the use of electronic instruments to allow remote monitoring

  18. Provider Agency Practices as a Source of Social Work EBP.

    Science.gov (United States)

    Blakely, Thomas J; Dziadosz, Gregory M

    2016-01-01

    Through this article the authors propose that agency service provider systems may be a source of evidence-based practices (EBP). One agency's design and implementation of a program entitled Community Treatment and Rehabilitation is presented as an example. The elements of this program conform to the creation of EBPs. It was formulated with consideration of clients' values and judgments through their participation at every step in the assessment and treatment process. Staff clinicians were trained in established EBP interventions, such as cognitive therapy, embedded in a system of ordered assessment, treatment, and outcome evaluation. A controlled research design was used to gather outcome data to inform clinicians' decisions about interventions that were then systematically applied with clients. The delivery system was organized for clinical supervisors to guide staff clinical practices so that all were operating on the same set of guidelines allowing for similar outcomes to occur with similar interventions. This method of developing EBPs makes them available for application immediately and successfully eliminates the delay between development and implementation that usually occurs with other sources of EBPs.

  19. The importance of governmental control of radioactive sources used in industrial applications

    International Nuclear Information System (INIS)

    Anna Firpo Fuerth, Q.F.; Beatriz Souto Ameigenda, Q.F.

    1998-01-01

    Industrial applications of radioactive sources require good management practices dealing with control and registration. In the following case, a special event occurred between two routine inspections: trading. Then a new human factor came into scene: workers with no specific training and knowledge related to radioactive sources. The up going situation triggered emergency procedures. Finally, there were no negative consequences. (author)

  20. Domestic Larval Control Practices and Malaria Prevalence among Under-Five Children in Burkina Faso.

    Directory of Open Access Journals (Sweden)

    Souleymane Diabaté

    Full Text Available Larval source management has contributed to malaria decline over the past years. However, little is known about the impact of larval control practices undertaken at the household level on malaria transmission.The study was conducted in Kaya health district after the 2010 mass distribution of insecticide treated-nets and the initiation of malaria awareness campaigns in Burkina Faso. The aim was to (i estimate the level of domestic larval control practices (cleaning of the house and its surroundings, eradication of larval sources, and elimination of hollow objects that might collect water; (ii identify key determinants; and (iii explore the structural relationships between these practices, participation in awareness-raising activities and mothers' knowledge/attitudes/practices, and malaria prevalence among under-five children.Overall, 2004 households were surveyed and 1,705 under-five children were examined. Half of the mothers undertook at least one action to control larval proliferation. Mothers who had gone to school had better knowledge about malaria and were more likely to undertake domestic larval control practices. Living in highly exposed rural areas significantly decreased the odds of undertaking larval control actions. Mothers' participation in malaria information sessions increased the adoption of vector control actions and bednet use. Malaria prevalence was statistically lower among children in households where mothers had undertaken at least one vector control action or used bed-nets. There was a 0.16 standard deviation decrease in malaria prevalence for every standard deviation increase in vector control practices. The effect of bednet use on malaria prevalence was of the same magnitude.Cleaning the house and its surroundings, eradicating breeding sites, and eliminating hollow objects that might collect water play a substantial role in preventing malaria among under-five. There is a need for national malaria control programs to

  1. 40 CFR 432.72 - Effluent limitations attainable by the application of the best practicable control technology...

    Science.gov (United States)

    2010-07-01

    ... application of the best practicable control technology currently available (BPT). 432.72 Section 432.72... AND POULTRY PRODUCTS POINT SOURCE CATEGORY Sausage and Luncheon Meats Processors § 432.72 Effluent limitations attainable by the application of the best practicable control technology currently available (BPT...

  2. Knowledge and use of the internet as a source of controlled substances.

    Science.gov (United States)

    M Gordon, Susan; Forman, Robert F; Siatkowski, Candis

    2006-04-01

    Despite growing evidence that the internet is a source of controlled substances for nonmedical use, there is a lack of information about who is using it to obtain these drugs. One hundred adult drug-dependent inpatients in a private residential treatment program participated in a semistructured interview regarding how they obtained their drugs. Twenty-nine percent reported knowledge of the internet as a source of drugs, and 11% reported that they had used the internet to either buy drugs or locate a drug dealer. The results of this preliminary study suggest that the internet has become a source of controlled substances for some addicted individuals. Considerations for future research and clinical practice are described.

  3. Irish psychiatric nurses' self-reported sources of knowledge for practice.

    LENUS (Irish Health Repository)

    Yadav, B L

    2012-02-01

    Evidence-based practice (EBP) is an approach to health care in which health professionals use the best evidence available to guide their clinical decisions and practice. Evidence is drawn from a range of sources, including published research, educational content and practical experience. This paper reports the findings of a study that investigated the sources of knowledge or evidence for practice used by psychiatric nurses in Ireland. The paper is part of a larger study, which also investigated barriers, facilitators and level of skills in achieving EBP among Irish psychiatric nurses. Data were collected in a postal survey of a random sample of Irish psychiatric nurses using the Development of Evidence-Based Practice Questionnaire. The findings revealed that the majority of survey respondents based their practice on information which was derived from interactions with patients, from their personal experience and from information shared by colleagues and members of the multidisciplinary team, in preference to published sources of empirically derived evidence. These findings are consistent with those of the previous similar studies among general nurses and suggest that Irish psychiatric nurses face similar challenges to their general nursing counterparts in attaining of EBP.

  4. Single Phase Current-Source Active Rectifier for Traction: Control System Design and Practical Problems

    Directory of Open Access Journals (Sweden)

    Jan Michalik

    2006-01-01

    Full Text Available This research has been motivated by industrial demand for single phase current-source active rectifier dedicated for reconstruction of older types of dc machine locomotives. This paper presents converters control structure design and simulations. The proposed converter control is based on the mathematical model and due to possible interaction with railway signaling and required low switching frequency employs synchronous PWM. The simulation results are verified by experimental tests performed on designed laboratory prototype of power of 7kVA

  5. Control of sealed radioactive sources in Peru

    International Nuclear Information System (INIS)

    Ramirez Quijada, R.

    2001-01-01

    The paper describes the inventory of radioactive sources in Peru and assesses the control. Three groups of source conditions are established: controlled sources, known sources, and lost and orphan sources. The potential risk, described as not significant, for producing accidents is established and the needed measures are discussed. The paper concludes that, while the control on sealed sources is good, there is still room for improvement. (author)

  6. Storage of low-level radioactive waste and regulatory control of sealed sources in Finland

    International Nuclear Information System (INIS)

    Rahola, T.; Markkanen, M.

    2006-01-01

    This paper is concentrated on the non nuclear low-level radioactive waste. The cornerstone for maintaining radioactive sources under control in Finland is that all practices involving sources are subject to authorization and all licensing information, including information on each individual source, are entered into a register which is continuously updated based on applications and notifications received from the licenses. Experiences during the past twenty years have shown that source-specific records of sources combined with regular inspections at the places of use have prevented efficiency losing control over sealed radioactive sources. The current capacity in the interim storage for State owned waste is not adequate for all used sealed sources and other small user waste which are currently kept in the possession of the licensees. Thus, expansion of the storage capacity and other options for taking care of the small user waste is under consideration. (N.C.)

  7. Regular, brief mindfulness meditation practice improves electrophysiological markers of attentional control

    Science.gov (United States)

    Moore, Adam; Gruber, Thomas; Derose, Jennifer; Malinowski, Peter

    2012-01-01

    Mindfulness-based meditation practices involve various attentional skills, including the ability to sustain and focus ones attention. During a simple mindful breathing practice, sustained attention is required to maintain focus on the breath while cognitive control is required to detect mind wandering. We thus hypothesized that regular, brief mindfulness training would result in improvements in the self-regulation of attention and foster changes in neuronal activity related to attentional control. A longitudinal randomized control group EEG study was conducted. At baseline (T1), 40 meditation naïve participants were randomized into a wait list group and a meditation group, who received three hours mindfulness meditation training. Twenty-eight participants remained in the final analysis. At T1, after eight weeks (T2) and after 16 weeks (T3), all participants performed a computerized Stroop task (a measure of attentional control) while the 64-channel EEG was recorded. Between T1 and T3 the meditators were requested to meditate daily for 10 min. Event-related potential (ERP) analysis highlighted two between group effects that developed over the course of the 16-week mindfulness training. An early effect at left and right posterior sites 160–240 ms post-stimulus indicated that meditation practice improved the focusing of attentional resources. A second effect at central posterior sites 310–380 ms post-stimulus reflects that meditation practice reduced the recruitment of resources during object recognition processes, especially for incongruent stimuli. Scalp topographies and source analyses (Variable Resolution Electromagnetic Tomography, VARETA) indicate relevant changes in neural sources, pertaining to left medial and lateral occipitotemporal areas for the early effect and right lateral occipitotemporal and inferior temporal areas for the later effect. The results suggest that mindfulness meditation may alter the efficiency of allocating cognitive resources

  8. Regular, brief mindfulness meditation practice improves electrophysiological markers of attentional control

    Directory of Open Access Journals (Sweden)

    Adam W Moore

    2012-02-01

    Full Text Available Mindfulness based meditation practices involve various attentional skills, including the ability to sustain and focus ones attention. During a simple mindful breathing practice, sustained attention is required to maintain focus on the breath while cognitive control is required to detect mind wandering. We thus hypothesized that regular, brief mindfulness training would result in improvements in the self regulation of attention and foster changes in neuronal activity related to attentional control.A longitudinal randomized control group EEG study was conducted. At baseline (T1, 40 meditation naïve participants were randomized into a wait list group and a meditation group, who received three hours mindfulness meditation training. 28 participants remained in the final analysis. At T1, after 8 weeks (T2 and after 16 weeks (T3, all participants performed a computerized Stroop task (a measure of attentional control while the 64-channel EEG was recorded. Between T1 and T3 the meditators were requested to meditate daily for ten minutes.Event-related potential (ERP analysis highlighted two between group effects that developed over the course of the 16-week mindfulness training. An early effect at left and right posterior sites 160 – 240 ms post stimulus indicated that meditation practice improved the focusing of attentional resources. A second effect at central posterior sites 310 – 380 ms post stimulus reflects that meditation practice reduced the recruitment of resources during object recognition processes, especially for incongruent stimuli. Scalp topographies and source analyses (VARETA indicate relevant changes in neural sources, pertaining to left medial and lateral occipitotemporal areas for the early effect and right lateral occipitotemporal and inferior temporal areas for the later effect.The results suggest that mindfulness meditation may alter the efficiency of allocating cognitive resources, leading to improved self regulation of

  9. The regulatory control over radiation sources: the Brazilian experience and some lessons learned from industrial applications

    International Nuclear Information System (INIS)

    Costa, E.L.C.; Gomes, J.D.R.L.; Gomes, R.S.; Costa, M.L.L.; Thomé, Z.D.; Instituto Militar de Engenharia

    2017-01-01

    This study gives an overview of the activities of the National Commission of Nuclear Energy (CNEN), as the Brazilian nuclear regulatory authority. These activities are described, especially those related to management of orphan sources and radioactive material in scrap metal considering the actions already put into place by CNEN during the licensing and controlling of radioactive sources in the industry and other facilities. In Brazil, there is not yet an effective system for controlling the scrap metal and recycling industry, thus a coordinated approach to achieve a harmonized and effective response with the involvement of third parties is needed, especially the metal industries and ores facilities. These practices call for stringent regulatory control, in order to reduce the occurrence of orphan sources, and consequently, radioactive material appearing in scrap metal. Some challenges of managing the national radiation sources register systems will be discussed, in order to cover effectively all the radiation source history (in a 'from the cradle to the grave' basis), and the dynamic maintenance and update of these data. The main industrial applications considered in this work are those dealing with constant movement of sources all over the country, with geographical issues to be considered in the managing and controlling actions, such as gammagraphy and well-logging. This study aims to identify and promote good practices to prevent inadvertent diversion of radioactive material, taking into account existing international recommendations and some lessons learned in national level. (author)

  10. The regulatory control over radiation sources: the Brazilian experience and some lessons learned from industrial applications

    Energy Technology Data Exchange (ETDEWEB)

    Costa, E.L.C.; Gomes, J.D.R.L.; Gomes, R.S.; Costa, M.L.L.; Thomé, Z.D., E-mail: evaldo@cnen.gov.br, E-mail: jlopes@cnen.gov.br, E-mail: rogeriog@cnen.gov.br, E-mail: mara@cnen.gov.br, E-mail: zielithome@gmail.com [Comissao Nacional de Energia Nuclear (CNEN), Rio de Janeiro, RJ (Brazil). Diretoria de Radioproteção e Segurança Nuclear; Instituto Militar de Engenharia (IME), Rio de Janeiro, RJ (Brazil). Seção de Engenharia Nuclear

    2017-11-01

    This study gives an overview of the activities of the National Commission of Nuclear Energy (CNEN), as the Brazilian nuclear regulatory authority. These activities are described, especially those related to management of orphan sources and radioactive material in scrap metal considering the actions already put into place by CNEN during the licensing and controlling of radioactive sources in the industry and other facilities. In Brazil, there is not yet an effective system for controlling the scrap metal and recycling industry, thus a coordinated approach to achieve a harmonized and effective response with the involvement of third parties is needed, especially the metal industries and ores facilities. These practices call for stringent regulatory control, in order to reduce the occurrence of orphan sources, and consequently, radioactive material appearing in scrap metal. Some challenges of managing the national radiation sources register systems will be discussed, in order to cover effectively all the radiation source history (in a 'from the cradle to the grave' basis), and the dynamic maintenance and update of these data. The main industrial applications considered in this work are those dealing with constant movement of sources all over the country, with geographical issues to be considered in the managing and controlling actions, such as gammagraphy and well-logging. This study aims to identify and promote good practices to prevent inadvertent diversion of radioactive material, taking into account existing international recommendations and some lessons learned in national level. (author)

  11. Neutron generator tube ion source control

    International Nuclear Information System (INIS)

    Bridges, J.R.

    1982-01-01

    A system is claimed for controlling the output of a neutron generator tube of the deuterium-tritium accelerator type and having an ion source to produce sharply defined pulses of neutrons for well logging use. It comprises: means for inputting a relatively low voltage input control pulse having a leading edge and a trailing edge; means, responsive to the input control pulse, for producing a relatively high voltage ion source voltage pulse after receipt of the input pulse; and means, responsive to the input control pulse, for quenching, after receipt of the input pulse, the ion source control pulse, thereby providing a sharply time defined neutron output from the generator tube

  12. Sealed radionuclide sources - new technical specifications and current practice

    Energy Technology Data Exchange (ETDEWEB)

    Brabec, D

    1987-03-01

    Basic technical specifications are discussed valid in Czechoslovakia for sealed radionuclide sources, based on international ISO and CMEA standards. Described are the standardization of terminology, relationships of tests, testing methods, types of sealed sources and their applications, relations to Czechoslovak regulations on radiation protection and to IAEA specifications for radioactive material shipment, etc. Practical impact is shown of the introduction of the new standards governing sealed sources on the national economy, and the purpose is explained of various documents issued with sealed sources. (author). 2 figs., 45 refs.

  13. Survey of tritiated oil sources and handling practices

    International Nuclear Information System (INIS)

    Miller, J.M.

    1994-08-01

    Tritium interactions with oil sources (primarily associated with pumps) in tritium-handling facilities can lead to the incorporation of tritium in the oil and the production of tritiated hydrocarbons. This results in a source of radiological hazard and the need for special handling considerations during maintenance, decontamination, decommissioning and waste packaging and storage. The results of a general survey of tritiated-oil sources and their associated characteristics, handling practices, analysis techniques and waste treatment/storage methods are summarized here. Information was obtained from various tritium-handling laboratories, fusion devices, and CANDU plants. 38 refs., 1 fig

  14. Regulatory Control of Radioactive Sources in Spain

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez, M.; Martin, J.L., E-mail: mrm@csn.es [Nuclear Safety Council, Madrid (Spain)

    2011-07-15

    The arrangements for the regulatory control of the safety and security of sealed radioactive sources in Spain are described. Emphasis is given to the situations which are most likely to result in the loss of control of sources and on the procedures introduced to reduce the likelihood of losses in these cases. Finally, the strategy for locating sources which have been lost from control (orphan sources) is described. (author)

  15. Control system for Siam photon source

    CERN Document Server

    Apiwatwaja, R; Isoyama, G; Ishii, T; Pairsuwan, W

    2003-01-01

    A new computer control system has been developed for Siam photon source, which is the first synchrotron light source in Thailand, personal computers and PLC's have been employed which are connected together through Ethernet. Man Machine Interface Stations (MMIS) at the front end act as a graphical user interface within Windows environment. The monitoring and controlling of individual devices is handled through several pairs of digital control station and the device interface located in each part of the synchrotron complex. The installation of the control system has been completed. The commissioning test of the control system is underway and the reliability of the system is on the positive side. Details of commissioning tests as well as characteristics of this newly built control system for the Siam photon source are described in this report.

  16. Protecting single-photon entanglement with practical entanglement source

    Science.gov (United States)

    Zhou, Lan; Ou-Yang, Yang; Wang, Lei; Sheng, Yu-Bo

    2017-06-01

    Single-photon entanglement (SPE) is important for quantum communication and quantum information processing. However, SPE is sensitive to photon loss. In this paper, we discuss a linear optical amplification protocol for protecting SPE. Different from the previous protocols, we exploit the practical spontaneous parametric down-conversion (SPDC) source to realize the amplification, for the ideal entanglement source is unavailable in current quantum technology. Moreover, we prove that the amplification using the entanglement generated from SPDC source as auxiliary is better than the amplification assisted with single photons. The reason is that the vacuum state from SPDC source will not affect the amplification, so that it can be eliminated automatically. This protocol may be useful in future long-distance quantum communications.

  17. Acoustic Source Localization and Beamforming: Theory and Practice

    Directory of Open Access Journals (Sweden)

    Chen Joe C

    2003-01-01

    Full Text Available We consider the theoretical and practical aspects of locating acoustic sources using an array of microphones. A maximum-likelihood (ML direct localization is obtained when the sound source is near the array, while in the far-field case, we demonstrate the localization via the cross bearing from several widely separated arrays. In the case of multiple sources, an alternating projection procedure is applied to determine the ML estimate of the DOAs from the observed data. The ML estimator is shown to be effective in locating sound sources of various types, for example, vehicle, music, and even white noise. From the theoretical Cramér-Rao bound analysis, we find that better source location estimates can be obtained for high-frequency signals than low-frequency signals. In addition, large range estimation error results when the source signal is unknown, but such unknown parameter does not have much impact on angle estimation. Much experimentally measured acoustic data was used to verify the proposed algorithms.

  18. A wavenumber approach to analysing the active control of plane waves with arrays of secondary sources

    Science.gov (United States)

    Elliott, Stephen J.; Cheer, Jordan; Bhan, Lam; Shi, Chuang; Gan, Woon-Seng

    2018-04-01

    The active control of an incident sound field with an array of secondary sources is a fundamental problem in active control. In this paper the optimal performance of an infinite array of secondary sources in controlling a plane incident sound wave is first considered in free space. An analytic solution for normal incidence plane waves is presented, indicating a clear cut-off frequency for good performance, when the separation distance between the uniformly-spaced sources is equal to a wavelength. The extent of the near field pressure close to the source array is also quantified, since this determines the positions of the error microphones in a practical arrangement. The theory is also extended to oblique incident waves. This result is then compared with numerical simulations of controlling the sound power radiated through an open aperture in a rigid wall, subject to an incident plane wave, using an array of secondary sources in the aperture. In this case the diffraction through the aperture becomes important when its size is compatible with the acoustic wavelength, in which case only a few sources are necessary for good control. When the size of the aperture is large compared to the wavelength, and diffraction is less important but more secondary sources need to be used for good control, the results then become similar to those for the free field problem with an infinite source array.

  19. Best practices for International eSourcing of Software Products and Services

    OpenAIRE

    Käkölä, Timo

    2008-01-01

    This paper analyzes how the information and communications technology-supported international eSourcing of software products and services (IeS) can be effectively executed. The extant literature falls short of providing a systematic and detailed enough set of best practices to guide IeS. This paper presents best practices for IeS to facilitate further research, and to help managers and other stakeholders to understand, execute, and proactively improve and manage international eSourcing. The p...

  20. Control of trafficking of radioactive sources/substances on European Community eastern border

    International Nuclear Information System (INIS)

    Lovjagina, Irina; Graveris, Visvaldis

    2008-01-01

    Full text: Taking into account Latvia geographical location, historical core stones (the dissolution of Soviet Union, join to European Community) and increasing of the international terrorism treats, control fissile and non-fissile radioactive material become one of high priorities. During past 2 years active work and practical exercise with representative from Ministry of Defense, Police, and Custom etc. on control of trafficking of such materials were performed and Operational Manual for Control on Radioactive Materials for Customs and Policy officers is issued. All land borders check points with Russian Federation and Byelorussian, all harbors and airports were equipped with a gamma/ neutrons or gamma control portals. To control unwanted material traffic within the country, as well as to ensure the recycled scrap metal is source-free use of monitoring portals and additional portable detectors in the past years strictly increased. Cases with alarm levels, when gamma dose rate exceeds more than 1.5 times the background level, are subject to reporting and analyzing by Radiation Safety Centre (RDC) experts (24 hours on duty). Consultative phone service for inhabitants is maintained; guidelines and working procedures within Authority and other Institutions involving were developed and implemented. As a result, in 2007 RDC has got 612 reports from the border. In 83% cases this was relevant to the trains, in 17%- to the trucks. Mostly enhanced activity was due to potassium compounds in fertilizers (85%), due to ceramics (4%), abrasives (2.5%), and refractory materials (3%). Controlling scrap metal there were revealed two sources in 2007 - one Sr-90 calibration source and other Cs-137 orphan source (origin unknown). The presence of radioactive sources in scrap in the past 3 years has been represented by Co-60, Cs-137 and Sr-90 sources, parts of statically electricity neutralizers, Ra-226. Several times NORM industries polluted materials were from scrap excluded

  1. Experience in the development and practical use of working control levels for radiation safety

    International Nuclear Information System (INIS)

    Epishin, A.V.

    1981-01-01

    The experience of development and practical use of working control levels (WCL) of radiation safety in the Gorky region, is discussed. WCL are introduced by ''Radiation Safety Guides'' (RSG-76) and have great practical importance. Regional control levels of radiation safety are determined for certain types of operations implying radioactive hazard and differentiated according to the types of sources applied and types of operation. Dose rates, radioactive contamination of operating surfaces, skin, air and waste water are subject to normalization. Limits of individual radiation doses specified according to operation categories are included. 10 tables of regional WCL indices are developed [ru

  2. Model predictive control for Z-source power converter

    DEFF Research Database (Denmark)

    Mo, W.; Loh, P.C.; Blaabjerg, Frede

    2011-01-01

    This paper presents Model Predictive Control (MPC) of impedance-source (commonly known as Z-source) power converter. Output voltage control and current control for Z-source inverter are analyzed and simulated. With MPC's ability of multi- system variables regulation, load current and voltage...

  3. Economics of Water Quality Protection from Nonpoint Sources: Theory and Practice

    OpenAIRE

    Ribaudo, Marc; Horan, Richard D.; Smith, Mark E.

    1999-01-01

    Water quality is a major environmental issue. Pollution from nonpoint sources is the single largest remaining source of water quality impairments in the United States. Agriculture is a major source of several nonpoint-source pollutants, including nutrients, sediment, pesticides, and salts. Agricultural nonpoint pollution reduction policies can be designed to induce producers to change their production practices in ways that improve the environmental and related economic consequences of produc...

  4. Some practical implications of source term reassessment

    International Nuclear Information System (INIS)

    1988-03-01

    This report provides a brief summary of the current knowledge of severe accident source terms and suggests how this knowledge might be applied to a number of specific aspects of reactor safety. In preparing the report, consideration has been restricted to source term issues relating to light water reactors (LWRs). Consideration has also generally been restricted to the consequences of hypothetical severe accidents rather than their probability of occurrence, although it is recognized that, in the practical application of source term research, it is necessary to take account of probability as well as consequences. The specific areas identified were as follows: Exploration of the new insights that are available into the management of severe accidents; Investigating the impact of source term research on emergency planning and response; Assessing the possibilities which exist in present reactor designs for preventing or mitigating the consequences of severe accidents and how these might be used effectively; Exploring the need for backfitting and assessing the implications of source term research for future designs; and Improving the quantification of the radiological consequences of hypothetical severe accidents for probabilistic safety assessments (PSAs) and informing the public about the realistic risks associated with nuclear power plants. 7 refs

  5. Original Research First aid practices, beliefs, and sources of ...

    African Journals Online (AJOL)

    Paediatric burn injury first aid practices, beliefs, information sources 151. © 2017 The ... The first aid measures used by the majority of caregivers were either incomplete or inadequate. Although some ..... Journal of emergency Nursing. 2010 ...

  6. The IAEA and Control of Radioactive Sources

    International Nuclear Information System (INIS)

    Dodd, B.

    2004-01-01

    The presentation discusses the authoritative functions and the departments of the IAEA, especially the Department of Nuclear Safety and Security and its Safety and Security of Radiation Sources Unit. IAEA safety series and IAEA safety standards series inform about international standards, provide underlying principles, specify obligations and responsibilities and give recommendations to support requirements. Other IAEA relevant publications comprise safety reports, technical documents (TECDOCs), conferences and symposium papers series and accident reports. Impacts of loss of source control is discussed, definitions of orphan sources and vulnerable sources is given. Accidents with orphan sources, radiological accidents statistic (1944-2000) and its consequences are discussed. These incidents lead to development of the IAEA guidance. The IAEA's action plan for the safety of radiation sources and the security of radioactive material was approved by the IAEA Board of Governors and the General Conference in September 1999. This led to the 'Categorization of Radiation Sources' and the 'Code of Conduct on the Safety and Security of Radioactive Sources'. After 0911 the IAEA developed a nuclear security plan of activities including physical protection of nuclear material and nuclear facilities, detection of malicious activities involving nuclear and other radioactive materials, state systems for nuclear material accountancy and control, security of radioactive material other than nuclear material, assessment of safety and security related vulnerability of nuclear facilities, response to malicious acts, or threats thereof, adherence to and implementation of international agreements, guidelines and recommendations and nuclear security co-ordination and information management. The remediation of past problems comprised collection and disposal of known disused sources, securing vulnerable sources and especially high-risk sources (Tripartite initiative), searching for

  7. Practices, patients and (imperfect data - feasibility of a randomised controlled clinical drug trial in German general practices

    Directory of Open Access Journals (Sweden)

    Hummers-Pradier Eva

    2011-04-01

    Full Text Available Abstract Background Randomised controlled clinical (drug trials supply high quality evidence for therapeutic strategies in primary care. Until now, experience with drug trials in German general practice has been sparse. In 2007/2008, the authors conducted an investigator-initiated, non-commercial, double-blind, randomised controlled pilot trial (HWI-01 to assess the clinical equivalence of ibuprofen and ciprofloxacin in the treatment of uncomplicated urinary tract infection (UTI. Here, we report the feasibility of this trial in German general practices and the implementation of Good Clinical Practice (GCP standards as defined by the International Conference on Harmonisation (ICH in mainly inexperienced general practices. Methods This report is based on the experience of the HWI-01 study conducted in 29 German general practices. Feasibility was defined by 1 successful practice recruitment, 2 sufficient patient recruitment, 3 complete and accurate data collection and 4 appropriate protection of patient safety. Results The final practice recruitment rate was 18%. In these practices, 79 of 195 screened UTI patients were enrolled. Recruitment differed strongly between practices (range 0-12, mean 2.8 patients per practice and was below the recruitment goal of approximately 100 patients. As anticipated, practice nurses became the key figures in the screening und recruitment of patients. Clinical trial demands, in particular for completing symptom questionnaires, documentation of source data and reporting of adverse events, did not agree well with GPs' documentation habits and required support from study nurses. In many cases, GPs and practice staff seemed to be overwhelmed by the amount of information and regulations. No sudden unexpected serious adverse reactions (SUSARs were observed during the trial. Conclusions To enable drug trials in general practice, it is necessary to adapt the setup of clinical research infrastructure to the needs of GPs and

  8. Advanced Light Source control system

    International Nuclear Information System (INIS)

    Magyary, S.; Chin, M.; Cork, C.; Fahmie, M.; Lancaster, H.; Molinari, P.; Ritchie, A.; Robb, A.; Timossi, C.

    1989-03-01

    The Advanced Light Source (ALS) is a third generation 1--2 GeV synchrotron radiation source designed to provide ports for 60 beamlines. It uses a 50 MeV electron linac and 1.5 GeV, 1 Hz, booster synchrotron for injection into a 1--2 GeV storage ring. Interesting control problems are created because of the need for dynamic closed beam orbit control to eliminate interaction between the ring tuning requirements and to minimize orbit shifts due to ground vibrations. The extremely signal sensitive nature of the experiments requires special attention to the sources of electrical noise. These requirements have led to a control system design which emphasizes connectivity at the accelerator equipment end and a large I/O bandwidth for closed loop system response. Not overlooked are user friendliness, operator response time, modeling, and expert system provisions. Portable consoles are used for local operation of machine equipment. Our solution is a massively parallel system with >120 Mbits/sec I/O bandwidth and >1500 Mips computing power. At the equipment level connections are made using over 600 powerful Intelligent Local Controllers (ILC-s) mounted in 3U size Eurocard slots using fiber-optic cables between rack locations. In the control room, personal computers control and display all machine variables at a 10 Hz rate including the scope signals which are collected though the control system. Commercially available software and industry standards are used extensively. Particular attention is paid to reliability, maintainability and upgradeability. 10 refs., 11 figs

  9. EPICS application source/release control

    International Nuclear Information System (INIS)

    Zieman, B.; Anderson, J.; Kraimer, M.

    1995-01-01

    This manual describes a set of Application Source/Release Control tools (appSR) that can be used to develop software for EPICS based control systems. The Application Source/Release Control System (appSR) has been unbundled from base EPICS and is now available as an EPICS extension. Due to this unbundling, two new directories must be added to a user's path (see section ''Environment'' on page 3 for more information) and a new command getapp must be issued after the getrel command to get a specific version of appSR (see section ''Creating The Initial Application System Area'' on page 7 for more information). It is now required that GNU make version 3.71 or later be used for makes instead of SUN make. Users should now type gmake instead of make

  10. Automatic control of a negative ion source

    International Nuclear Information System (INIS)

    Saadatmand, K.; Sredniawski, J.; Solensten, L.

    1989-01-01

    A CAMAC based control architecture is devised for a Berkeley-type H - volume ion source. The architecture employs three 80386 PCs. One PC is dedicated to control and monitoring of source operation. The other PC functions with digitizers to provide data acquisition of waveforms. The third PC is used for off-line analysis. Initially, operation of the source was put under remote computer control (supervisory). This was followed by development of an automated startup procedure. Finally, a study of the physics of operation is now underway to establish a data base from which automatic beam optimization can be derived. (orig.)

  11. Automatic control of a negative ion source

    Science.gov (United States)

    Saadatmand, K.; Sredniawski, J.; Solensten, L.

    1989-04-01

    A CAMAC based control architecture is devised for a Berkeley-type H - volume ion source [1]. The architecture employs three 80386 TM PCs. One PC is dedicated to control and monitoring of source operation. The other PC functions with digitizers to provide data acquisition of waveforms. The third PC is used for off-line analysis. Initially, operation of the source was put under remote computer control (supervisory). This was followed by development of an automated startup procedure. Finally, a study of the physics of operation is now underway to establish a data base from which automatic beam optimization can be derived.

  12. Automatic control of a negative ion source

    Energy Technology Data Exchange (ETDEWEB)

    Saadatmand, K.; Sredniawski, J.; Solensten, L. (Grumman Corp., Long Island, NY (USA))

    1989-04-01

    A CAMAC based control architecture is devised for a Berkeley-type H/sup -/ volume ion source. The architecture employs three 80386 PCs. One PC is dedicated to control and monitoring of source operation. The other PC functions with digitizers to provide data acquisition of waveforms. The third PC is used for off-line analysis. Initially, operation of the source was put under remote computer control (supervisory). This was followed by development of an automated startup procedure. Finally, a study of the physics of operation is now underway to establish a data base from which automatic beam optimization can be derived. (orig.).

  13. The competent person in radiation protection: practical radiation protection for industry and research - unsealed sources

    International Nuclear Information System (INIS)

    Bruchet, H.

    2009-01-01

    The mission of the competent person in radiation protection has been broadly developed these last years to take an essential function in firm:study of working place, delimitation of regulated areas, monitoring of exposure, relations with authorities. The competent person in radiation protection must follow a training, defined by decree and shared in two parts: a theoretical part used as compulsory subjects and a practical part specific to the different sectors of activity (research, industry, medical centers, nuclear facilities) as well as the radiation use type. This volume corresponds to the practical module devoted to the industrial and research facilities concerned by the possession of management of sealed or unsealed sources. In accordance with the regulations stipulating that this module must allow to apply the theoretical knowledge to concrete situations in work. It includes eight chapters as following: radiation protection in industrial and research facilities, use of sources and associated risks, fitting out professional premises, evaluation of exposure, control of radiation protection; use of detection equipment and radioactive contamination and exposure measurement equipment, associated to methods and calculation tools; radioactive waste management; accidental or damaged situations management; methodology of working place analysis completed by the application to practical cases found in laboratories. (N.C.)

  14. Control of sources of ionizing radiation in Lithuania

    International Nuclear Information System (INIS)

    Mastauskas, Albinas; Ziliukas, Julius; Morkunas, Gendrutis

    1997-01-01

    Aspects connected with regulatory control of radioactive sources in Lithuania, such as keeping of the computer-based registry, investigation of arrested illegal radioactive material, decision making, control of users of radioactive sources are discussed. Most of the sources of ionizing radiation are smoke detectors and x-ray equipment. Potentially most dangerous sources (both sealed and unsealed) of therapy and industry are also presented

  15. Control of radiation sources in Japan

    International Nuclear Information System (INIS)

    Maki, S.

    2001-01-01

    The report refers to the regulations for radioactive material in force in Japan, and to the organizations with responsibilities for regulating radiation sources. An outline of the law regulating the use of radiation sources and radioactive materials is provided, including its scope, types of radiation sources under control, exemptions and the system of notification, authorization and inspection. The experience of Japan with orphan sources is presented in three different cases, and the measures carried out to store the orphan sources in safe conditions. (author)

  16. Software engineering practices for control system reliability

    International Nuclear Information System (INIS)

    S. K. Schaffner; K. S White

    1999-01-01

    This paper will discuss software engineering practices used to improve Control System reliability. The authors begin with a brief discussion of the Software Engineering Institute's Capability Maturity Model (CMM) which is a framework for evaluating and improving key practices used to enhance software development and maintenance capabilities. The software engineering processes developed and used by the Controls Group at the Thomas Jefferson National Accelerator Facility (Jefferson Lab), using the Experimental Physics and Industrial Control System (EPICS) for accelerator control, are described. Examples are given of how their procedures have been used to minimized control system downtime and improve reliability. While their examples are primarily drawn from their experience with EPICS, these practices are equally applicable to any control system. Specific issues addressed include resource allocation, developing reliable software lifecycle processes and risk management

  17. Inadequate control of world's radioactive sources

    International Nuclear Information System (INIS)

    2002-01-01

    The radioactive materials needed to build a 'dirty bomb' can be found in almost any country in the world, and more than 100 countries may have inadequate control and monitoring programs necessary to prevent or even detect the theft of these materials. The IAEA points out that while radioactive sources number in the millions, only a small percentage have enough strength to cause serious radiological harm. It is these powerful sources that need to be focused on as a priority. In a significant recent development, the IAEA, working in collaboration with the United States Department of Energy (DOE) and the Russian Federation's Ministry for Atomic Energy (MINATOM), have established a tripartite working group on 'Securing and Managing Radioactive Sources'. Through its program to help countries improve their national infrastructures for radiation safety and security, the IAEA has found that more than 100 countries may have no minimum infrastructure in place to properly control radiation sources. However, many IAEA Member States - in Africa, Asia, Latin America, and Europe - are making progress through an IAEA project to strengthen their capabilities to control and regulate radioactive sources. The IAEA is also concerned about the over 50 countries that are not IAEA Member States (there are 134), as they do not benefit from IAEA assistance and are likely to have no regulatory infrastructure. The IAEA has been active in lending its expertise to search out and secure orphaned sources in several countries. More than 70 States have joined with the IAEA to collect and share information on trafficking incidents and other unauthorized movements of radioactive sources and other radioactive materials. The IAEA and its Member States are working hard to raise levels of radiation safety and security, especially focusing on countries known to have urgent needs. The IAEA has taken the leading role in the United Nations system in establishing standards of safety, the most significant of

  18. Control of sources of ionizing radiation in Lithuania

    Energy Technology Data Exchange (ETDEWEB)

    Mastauskas, Albinas; Ziliukas, Julius; Morkunas, Gendrutis [Radiation Protection Centre, Vilnius (Lithuania)

    1997-12-31

    Aspects connected with regulatory control of radioactive sources in Lithuania, such as keeping of the computer-based registry, investigation of arrested illegal radioactive material, decision making, control of users of radioactive sources are discussed. Most of the sources of ionizing radiation are smoke detectors and x-ray equipment. Potentially most dangerous sources (both sealed and unsealed) of therapy and industry are also presented 2 refs., 2 tabs.; e-mail: rsc at post.omnitel.net

  19. Neutron generator tube ion source control apparatus

    International Nuclear Information System (INIS)

    Bridges, J.R.

    1982-01-01

    A pulsed neutron well logging system includes a neutron generator tube of the deuterium-tritium accelerator type and an ion source control apparatus providing extremely sharply time-defined neutron pulses. A low voltage control pulse supplied to an input by timing circuits turns a power FET on via a buffer-driver whereby a 2000 volt pulse is produced in the secondary of a pulse transformer and applied to the ion source of the tube. A rapid fall in this ion source control pulse is ensured by a quenching circuit wherein a one-shot responds to the falling edge of the control pulse and produces a 3 microsecond delay to compensate for the propagation delay. A second one-shot is triggered by the falling edge of the output of the first one-shot and gives an 8 microsecond pulse to turn on the power FET which, via an isolation transformer turns on a series-connected transistor to ground the secondary of the pulse transformer and the ion source. (author)

  20. Exploring sources of knowledge utilized in practice among Jordanian registered nurses.

    Science.gov (United States)

    Al-Ghabeesh, Suhair Husni; Abu-Moghli, Fathieh; Salsali, Mahvash; Saleh, Mohammad

    2013-10-01

    Understanding sources of knowledge used in everyday practice is very helpful in improving the quality of health care services. There is a consensus in the literature that nurses mostly relied in their practice on experiential knowledge gained through their interactions with other members of health care professionals and patients. The general aim of this study is to explore the sources of knowledge Jordanian registered nurses use during their practice. A descriptive correlational design was used to collect data from 539 Jordanian registered nurses from 10 hospitals using a self-administered questionnaire. The mean year of experience of the sample was 7.08 years. Of the 615 questionnaires distributed, 555 were returned. This yields a response rate of 87.6%. Results revealed that the top five ranked sources used by Jordanian registered nurses include: the information that nurses learned during nursing education, personal experience in nursing over time, what was learned through providing care to patients, information gained through discussion between physicians and nurses about patients, and information from policy and procedure manuals. Jordanian registered nurses recognize the value of research and that research utilization (RU) is an important issue and must not be ignored. The study has many implications for practice, education and research. Health care managers and decision makers need to play a more visible and instrumental role in encouraging RU to improve patients' quality of life. © 2012 John Wiley & Sons Ltd.

  1. Adaptive change in corporate control practices.

    Science.gov (United States)

    Alexander, J A

    1991-03-01

    Multidivisional organizations are not concerned with what structure to adopt but with how they should exercise control within the divisional form to achieve economic efficiencies. Using an information-processing framework, I examined control arrangements between the headquarters and operating divisions of such organizations and how managers adapted control practices to accommodate increasing environmental uncertainty. Also considered were the moderating effects of contextual attributes on such adaptive behavior. Analyses of panel data from 97 multihospital systems suggested that organizations generally practice selective decentralization under conditions of increasing uncertainty but that organizational age, dispersion, and initial control arrangements significantly moderate the direction and magnitude of such changes.

  2. Time-lapse controlled-source electromagnetics using interferometry

    NARCIS (Netherlands)

    Hunziker, J.W.; Slob, E.C.; Wapenaar, C.P.A.

    In time-lapse controlled-source electromagnetics, it is crucial that the source and the receivers are positioned at exactly the same location at all times of measurement. We use interferometry by multidimensional deconvolution (MDD) to overcome problems in repeatability of the source location.

  3. A practical algorithm for distribution state estimation including renewable energy sources

    Energy Technology Data Exchange (ETDEWEB)

    Niknam, Taher [Electronic and Electrical Department, Shiraz University of Technology, Modares Blvd., P.O. 71555-313, Shiraz (Iran); Firouzi, Bahman Bahmani [Islamic Azad University Marvdasht Branch, Marvdasht (Iran)

    2009-11-15

    Renewable energy is energy that is in continuous supply over time. These kinds of energy sources are divided into five principal renewable sources of energy: the sun, the wind, flowing water, biomass and heat from within the earth. According to some studies carried out by the research institutes, about 25% of the new generation will be generated by Renewable Energy Sources (RESs) in the near future. Therefore, it is necessary to study the impact of RESs on the power systems, especially on the distribution networks. This paper presents a practical Distribution State Estimation (DSE) including RESs and some practical consideration. The proposed algorithm is based on the combination of Nelder-Mead simplex search and Particle Swarm Optimization (PSO) algorithms, called PSO-NM. The proposed algorithm can estimate load and RES output values by Weighted Least-Square (WLS) approach. Some practical considerations are var compensators, Voltage Regulators (VRs), Under Load Tap Changer (ULTC) transformer modeling, which usually have nonlinear and discrete characteristics, and unbalanced three-phase power flow equations. The comparison results with other evolutionary optimization algorithms such as original PSO, Honey Bee Mating Optimization (HBMO), Neural Networks (NNs), Ant Colony Optimization (ACO), and Genetic Algorithm (GA) for a test system demonstrate that PSO-NM is extremely effective and efficient for the DSE problems. (author)

  4. Quantifying consumer portion control practices

    DEFF Research Database (Denmark)

    Spence, M.; Lähteenmäki, Liisa; Stancu, Violeta

    2015-01-01

    of Ireland. Three factors were extracted and named: measurement-strategy scale, eating-strategy scale, and purchasing-strategy scale. The eating-strategy scale score was the highest, while the measurement-strategy scale carried the lowest frequency score. For each strategy scale score, the strongest...... predictor was GHI, followed by gender. Having higher GHI and being female were independently associated with more frequent portion control. Both the eating-strategy scale score and the purchasing-strategy scale score were negatively associated with pizza portion size consumption estimates. In conclusion......, while this study demonstrates that the reported use of portion control practices is low, the findings provide preliminary evidence for their validity. Further studies are needed to explore how portion control practices are used in different kinds of portion size decisions and what their contribution...

  5. Problems in the fingerprints based polycyclic aromatic hydrocarbons source apportionment analysis and a practical solution

    International Nuclear Information System (INIS)

    Zou, Yonghong; Wang, Lixia; Christensen, Erik R.

    2015-01-01

    This work intended to explain the challenges of the fingerprints based source apportionment method for polycyclic aromatic hydrocarbons (PAH) in the aquatic environment, and to illustrate a practical and robust solution. The PAH data detected in the sediment cores from the Illinois River provide the basis of this study. Principal component analysis (PCA) separates PAH compounds into two groups reflecting their possible airborne transport patterns; but it is not able to suggest specific sources. Not all positive matrix factorization (PMF) determined sources are distinguishable due to the variability of source fingerprints. However, they constitute useful suggestions for inputs for a Bayesian chemical mass balance (CMB) analysis. The Bayesian CMB analysis takes into account the measurement errors as well as the variations of source fingerprints, and provides a credible source apportionment. Major PAH sources for Illinois River sediments are traffic (35%), coke oven (24%), coal combustion (18%), and wood combustion (14%). - Highlights: • Fingerprint variability poses challenges in PAH source apportionment analysis. • PCA can be used to group compounds or cluster measurements. • PMF requires results validation but is useful for source suggestion. • Bayesian CMB provide practical and credible solution. - A Bayesian CMB model combined with PMF is a practical and credible fingerprints based PAH source apportionment method

  6. Orphan sources control in the Republic of Korea

    International Nuclear Information System (INIS)

    Kim, C.-W.

    2001-01-01

    In this paper, the orphan source control programme in Korea will be discussed. Orphan sources are, in general, classified into three groups: 1) Illegally trafficking radioactive sources; 2) Domestic loss of radioactive sources due to the bankruptcy of licensees or authorized suppliers; and 3) Contaminated metal scrap, which has been imported. There are, currently, two approaches going on to control and manage orphan sources in Korea. First, the Korean regulatory authority (Ministry of Science and Technology: MOST) will fully run an information system on radiation safety to effectively trace and monitor all radioactive sources in the country by the year 2001. Second, the regulatory authority strongly advises steel mill companies to closely scrutinize and inspect scrap metal through a scrap monitoring system when they attempt to reutilize it in order to prevent it from being contaminated by uncontrolled sources. The Korea Institute of Nuclear Safety (KINS), a regulatory expert organization, is carrying out a three-year multiphase project to control and monitor orphan sources in Korea. The system, called the Information System on Integrated Radiation Safety (ISIRS) on the inter- and intra-net system has been developed to effectively control and accurately monitor radioactive sources on a real time basis since 1998. If the system is successfully set up as scheduled by the middle of May next year, the regulatory authority will be able to control any reutilization of uncontrolled sources efficiently. At the same time, the system can also provide, not only licensees, suppliers, or perspective end users but also the Korean general public of interests with information on radiation safety, safe radiation management tools and public services. The system has been created because of the necessity to effectively control radioactive sources safely. Also, it serves to prepare necessary protective measures in a timely manner for abnormal events of uncontrolled radiation from

  7. Standard practice for strain controlled thermomechanical fatigue testing

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This practice covers the determination of thermomechanical fatigue (TMF) properties of materials under uniaxially loaded strain-controlled conditions. A “thermomechanical” fatigue cycle is here defined as a condition where uniform temperature and strain fields over the specimen gage section are simultaneously varied and independently controlled. This practice is intended to address TMF testing performed in support of such activities as materials research and development, mechanical design, process and quality control, product performance, and failure analysis. While this practice is specific to strain-controlled testing, many sections will provide useful information for force-controlled or stress-controlled TMF testing. 1.2 This practice allows for any maximum and minimum values of temperature and mechanical strain, and temperature-mechanical strain phasing, with the restriction being that such parameters remain cyclically constant throughout the duration of the test. No restrictions are placed on en...

  8. Implementation of VOC source reduction practices in a manufactured house and in school classrooms

    International Nuclear Information System (INIS)

    Hodgson, A.T.; Apte, M.G.; Shendell, D.G.; Beal, D.; McIlvaine, J.E.R.

    2002-01-01

    Detailed studies of a new manufactured house and four new industrialized relocatable school classrooms were conducted to determine the emission sources of formaldehyde and other VOCs and to identify and implement source reduction practices. Procedures were developed to generate VOC emission factors that allowed reasonably accurate predictions of indoor air VOC concentrations. Based on the identified sources of formaldehyde and other aldehydes, practices were developed to reduce the concentrations of these compounds in new house construction. An alternate ceiling panel reduced formaldehyde concentrations in the classrooms. Overall, the classrooms had relatively low VOC concentrations

  9. Standard Practice for Conducting Irradiations at Accelerator-Based Neutron Sources

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1996-01-01

    1.1 This practice covers procedures for irradiations at accelerator-based neutron sources. The discussion focuses on two types of sources, namely nearly monoenergetic 14-MeV neutrons from the deuterium-tritium T(d,n) interaction, and broad spectrum neutrons from stopping deuterium beams in thick beryllium or lithium targets. However, most of the recommendations also apply to other types of accelerator-based sources, including spallation neutron sources (1). Interest in spallation sources has increased recently due to their proposed use for transmutation of fission reactor waste (2). 1.2 Many of the experiments conducted using such neutron sources are intended to simulate irradiation in another neutron spectrum, for example, that from a DT fusion reaction. The word simulation is used here in a broad sense to imply an approximation of the relevant neutron irradiation environment. The degree of conformity can range from poor to nearly exact. In general, the intent of these simulations is to establish the fundam...

  10. Software architecture considerations for ion source control systems

    International Nuclear Information System (INIS)

    Sinclair, J.W.

    1997-09-01

    General characteristics of distributed control system software tools are examined from the perspective of ion source control system requirements. Emphasis is placed on strategies for building extensible, distributed systems in which the ion source element is one component of a larger system. Vsystem, a commercial software tool kit from Vista Control Systems was utilized extensively in the control system upgrade of the Holifield Radioactive Ion Beam Facility. Part of the control system is described and the characteristics of Vsystem are examined and compared with those of EPICS, the Experimental Physics and Industrial Control System

  11. Good control practices underlined by an on-line fuzzy control database

    Directory of Open Access Journals (Sweden)

    Alonso, M. V.

    1994-04-01

    Full Text Available In the olive oil trade, control systems that automate extraction processes, cutting production costs and increasing processing capacity without losing quality, are always desirable. The database structure of an on-line fuzzy control of centrifugation systems and the algorithms used to attain the best control conditions are analysed. Good control practices are suggested to obtain virgin olive oil of prime quality.

    In the olive oil trade, control systems that automate extraction processes, cutting production costs and increasing processing capacity without losing quality, are always desirable. The database structure of an on-line fuzzy control of centrifugation systems and the algorithms used to attain the best control conditions are analysed. Good control practices are suggested to obtain virgin olive oil of prime quality.

  12. Radiographic Control of 137-Cs Brachytherapy Sources

    International Nuclear Information System (INIS)

    Bistrovic, M.; Viculin, T.; Jurkovic, S.

    2003-01-01

    1 37C s brachytherapy sources are practical for the intracavitary application due to their relatively long lifetime (T 1/2 = 30 y). On the other hand, due to the relatively low energy (0.66 MeV) of the emitted photons, they are suitable for an efficient radiation protection. The dose distribution around the sources is usually calculated by a specific program. However this program requires the knowledge of the position of sources within the applicator as well as the distribution of activity along them. The only way to learn these data is to make an X-ray picture of applicators and sources superimposed to the autoradiography of every source. It is difficult to achieve satisfactory radiographs with high dose rate sources with standard X-ray film material because autoradiography covers the structure of the radiographic shadow. The problem can be overcome either by applying a high intensity X-ray or gamma beam (originating from a radiotherapeutic machine), or by using photographic material of very low sensitivity, for example photographic paper. Combining both possibilities one can obtain satisfactory images. (author)

  13. A Practical Method of Acoustic Emission Source Location in Anisotropic Composite Laminates

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jeong Kon; Kang, Yong Kyu; Kwon, Oh Yang [Inha University, Incheon (Korea, Republic of)

    2003-06-15

    Since the velocity is dependent on the fiber orientation in anisotropic composites, the application of traditional acoustic emission (AE) source location techniques based on the constant velocity to composite structures has been practically impossible. The anisotropy makes the source location procedure complicated and deteriorates the accuracy of the location. In this study, we have divided the region of interest(ROI) into a set of finite elements, taken each element as a virtual source, and calculated the arrival time differences between sensors by using the velocities at every degree from 0 to 90. The calculated and the experimentally measured values of the arrival time difference aye then compared to minimize the location error. The results from two different materials, namely AA6061-T6 and CFRP(uni-directional; UD, [0]{sub 32}4 ) laminate confirmed the practical usefulness of the proposed method

  14. The regulatory control of ionizing radiation sources in Lithuania

    International Nuclear Information System (INIS)

    Mastauskas, A.; Ziliukas, J.; Morkunas, G.

    1998-01-01

    The Radiation Protection Centre of the Ministry of Health is the regulatory authority responsible for radiation protection of the public and of workers using sources of ionizing radiation in Lithuania. One of its responsibilities is the control of radioactive sources, which includes keeping the registry, investigating persons arrested while illegally carrying or in possession of radioactive material, decision making and control of users of radioactive sources. The computer based registry contains a directory of more than 24,000 sources and some 800 users in research, medicine and industry. Most of these sources are found in smoke detectors and X ray equipment. The potentially most dangerous sources for therapy and industry (sealed and unsealed) are also listed in this registry. Problems connected with the regulatory control of radioactive sources in Lithuania are presented and their solution is discussed. (author)

  15. Control of sealed sources and equipments used in gammagraphy

    International Nuclear Information System (INIS)

    Sahyun, A.; Sordi, G.-M.A.A.; Biazzini Filho, F.L.

    1988-01-01

    The Radiation Protection Department of the IPEN-CNEN/SP, in 1987, formed a section incharged to control all radioactive material: a) received by the IPEN-CNEN/SP; b) produced by the IPEN-CNEN/SP; c) delivered from the IPEN-CNEN/SP. The aim of this section is to maintain a permanent control of all radioactive sources movement got at the IPEN-CNEN/SP. This control is performed with a microcomputer, trademark MICRODIGITAL, model TK3000 //e, 256 KBytes of memory, utilizing the TOTALWORKS program. This program permits to have the origin, characteristics and address of the radioactive sources, its sites in the IPEN, its uses, etc. Already we have put in the microcomputer, the control of the sealed sources produced used in nondestructive test, the inspection control of the gamagraphy irradiator and the control of the depleted sources. The next step is to introduce in the computer the inspection of the remote control of the irradiator. The aim of this paper is to describe the control program that was already put on. This radioactive material control was started with the sealed sources used in gamagraphy because we believe that is the field with the most likelihood of accident in the population, and therefore it's that need the most hard control about the site and the performance of the irradiation facility. (author) [pt

  16. Using Positive Deviance for Determining Successful Weight-Control Practices

    Science.gov (United States)

    Stuckey, Heather L.; Boan, Jarol; Kraschnewski, Jennifer L.; Miller-Day, Michelle; Lehman, Erik B.; Sciamanna, Christopher N.

    2013-01-01

    Based on positive deviance (examining the practices of successful individuals), we identified five primary themes from 36 strategies that help to maintain long-term weight loss (weight control) in 61 people. We conducted in-depth interviews to determine what successful individuals did and/or thought about regularly to control their weight. The themes included weight-control practices related to (a) nutrition: increase water, fruit, and vegetable intake, and consistent meal timing and content; (b) physical activity: follow and track an exercise routine at least 3×/week; (c) restraint: practice restraint by limiting and/or avoiding unhealthy foods; (d) self-monitor: plan meals, and track calories/weight progress; and (e) motivation: participate in motivational programs and cognitive processes that affect weight-control behavior. Using the extensive data involving both the practices and practice implementation, we used positive deviance to create a comprehensive list of practices to develop interventions for individuals to control their weight. PMID:20956609

  17. 10 CFR 36.31 - Control of source movement.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Control of source movement. 36.31 Section 36.31 Energy NUCLEAR REGULATORY COMMISSION LICENSES AND RADIATION SAFETY REQUIREMENTS FOR IRRADIATORS Design and Performance Requirements for Irradiators § 36.31 Control of source movement. (a) The mechanism that moves the...

  18. Low-level rf control of Spallation Neutron Source: System and characterization

    Directory of Open Access Journals (Sweden)

    Hengjie Ma

    2006-03-01

    Full Text Available The low-level rf control system currently commissioned throughout the Spallation Neutron Source (SNS LINAC evolved from three design iterations over 1 yr intensive research and development. Its digital hardware implementation is efficient, and has succeeded in achieving a minimum latency of less than 150 ns which is the key for accomplishing an all-digital feedback control for the full bandwidth. The control bandwidth is analyzed in frequency domain and characterized by testing its transient response. The hardware implementation also includes the provision of a time-shared input channel for a superior phase differential measurement between the cavity field and the reference. A companion cosimulation system for the digital hardware was developed to ensure a reliable long-term supportability. A large effort has also been made in the operation software development for the practical issues such as the process automations, cavity filling, beam loading compensation, and the cavity mechanical resonance suppression.

  19. Prediction of 4H–SiC betavoltaic microbattery characteristics based on practical Ni-63 sources

    International Nuclear Information System (INIS)

    Gui, Gui; Zhang, Kan; Blanchard, James P.; Ma, Zhenqiang

    2016-01-01

    We have investigated the performance of 4H–SiC betavoltaic microbatteries under exposure to the practical Ni-63 sources using the Monte Carlo method and Synopsys® Medici device simulator. A typical planar p–n junction betavoltaic device with the Ni-63 source of 20% purity on top is modeled in the simulation. The p–n junction structure includes a p+ layer, a p− layer, an n+ layer, and an n− layer. In order to obtain an accurate and valid predication, our simulations consider several practical factors, including isotope impurities, self-absorption, and full beta energy spectra. By simulating the effects of both the p–n junction configuration and the isotope source thickness on the battery output performance, we have achieved the optimal design of the device and maximum energy conversion efficiency. Our simulation results show that the energy conversion efficiency increases as the doping concentration and thickness of the p− layer increase, whereas it is independent of the total depth of the p–n junction. Furthermore, the energy conversion efficiency decreases as the thickness of the practical Ni-63 source increases, because of self-absorption in the isotope source. Therefore, we propose that a p–n junction betavoltaic cell with a thicker and heavily doped p− layer under exposure to a practical Ni-63 source with an appreciable thickness could produce the optimal energy conversion efficiency. - Highlights: • Different thicknesses of Ni-63 isotope sources with 20% purity were employed. • A self-absorption model was constructed for the beta energy spectra of Ni-63 sources. • The optimization strategies for betavoltaic microbatteries were outlined.

  20. Pollution source control by water utilities – characterisation and implications for water management: research results from England and Wales

    NARCIS (Netherlands)

    Spiller, M.; McIntosh, B.S.; Seaton, R.A.F.; Jeffrey, P.

    2013-01-01

    The treatment of agriculturally polluted water to potable standards is costly for water companies. Changes in agricultural practice can reduce these costs while also meeting the objectives of European Union (EU) environmental legislation. In this paper, the uptake of source control interventions

  1. Infection prevention and control in outpatient settings in China-structure, resources, and basic practices.

    Science.gov (United States)

    Qiao, Fu; Huang, Wenzhi; Zong, Zhiyong; Yin, Weijia

    2018-01-25

    More than 7 billion visits are made by patients to ambulatory services every year in mainland China. Healthcare-associated infections are becoming a new source of illness for outpatients. Little is known about infection prevention, control structure, resources available, and basic practices in outpatient settings. In 2014, we conducted a multisite survey. Five provinces were invited to participate based on geographic dispersion. Self-assessment questionnaires regarding the structure, infrastructure, apparatus and materials, and basic activities of infection prevention and control were issued to 25 hospitals and 5 community health centers in each province. A weight was assigned to each question according to its importance. Overall, 146 of 150 facilities (97.3%) participated in this study. The average survey score was 77.6 (95% confidence interval 75.7-79.5) and varied significantly between the different gross domestic product areas (P infection prevention and control was practiced consistently, although there were lapses in some areas. Copyright © 2017 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  2. Respiratory source control using a surgical mask: An in vitro study.

    Science.gov (United States)

    Patel, Rajeev B; Skaria, Shaji D; Mansour, Mohamed M; Smaldone, Gerald C

    2016-07-01

    Cough etiquette and respiratory hygiene are forms of source control encouraged to prevent the spread of respiratory infection. The use of surgical masks as a means of source control has not been quantified in terms of reducing exposure to others. We designed an in vitro model using various facepieces to assess their contribution to exposure reduction when worn at the infectious source (Source) relative to facepieces worn for primary (Receiver) protection, and the factors that contribute to each. In a chamber with various airflows, radiolabeled aerosols were exhaled via a ventilated soft-face manikin head using tidal breathing and cough (Source). Another manikin, containing a filter, quantified recipient exposure (Receiver). The natural fit surgical mask, fitted (SecureFit) surgical mask and an N95-class filtering facepiece respirator (commonly known as an "N95 respirator") with and without a Vaseline-seal were tested. With cough, source control (mask or respirator on Source) was statistically superior to mask or unsealed respirator protection on the Receiver (Receiver protection) in all environments. To equal source control during coughing, the N95 respirator must be Vaseline-sealed. During tidal breathing, source control was comparable or superior to mask or respirator protection on the Receiver. Source control via surgical masks may be an important adjunct defense against the spread of respiratory infections. The fit of the mask or respirator, in combination with the airflow patterns in a given setting, are significant contributors to source control efficacy. Future clinical trials should include a surgical mask source control arm to assess the contribution of source control in overall protection against airborne infection.

  3. Self-optimizing control of air-source heat pump with multivariable extremum seeking

    International Nuclear Information System (INIS)

    Dong, Liujia; Li, Yaoyu; Mu, Baojie; Xiao, Yan

    2015-01-01

    The air-source heat pump (ASHP) is widely adopted for cooling and heating of residential and commercial buildings. The performance of ASHP can be controlled by several operating variables, such as compressor capacity, condenser fan speed, evaporator fan speed and suction superheat. In practice, the system characteristics can be varied significantly by the variations in ambient condition, operation setpoint, internal thermal load and equipment degradation, which makes it difficult to obtain accurate plant models. As consequence, the model based control strategies for ASHP could limit the achievable energy efficiency. Model-free self-optimizing control strategies are thus more preferable. In this study, a multi-input extremum seeking control (ESC) scheme is proposed for both heating and cooling operation of ASHP. The zone temperature is assumed to be regulated by the compressor capacity, while the expansion valve opening is used to regulate the suction superheat at the given setpoint. The total power consumption of the compressor, the condenser fan and the evaporator fan is measured as input to the ESC, while the ESC controls the evaporator fan speed, the condenser fan speed and the suction superheat setpoint. The proposed scheme is evaluated with a Modelica based dynamic simulation model of ASHP under both cooling and heating modes of operation. Simulation results show the effectiveness of the proposed scheme to achieve the maximum achievable efficiency in a nearly model-free manner. - Highlights: • Multi-input ESC. • Air-source heat pump. • Cooling and heating. • Modelica based model

  4. Regulatory Control of Radiation Sources. Safety Guide

    International Nuclear Information System (INIS)

    2009-01-01

    This Safety Guide is intended to assist States in implementing the requirements established in Safety Standards Series No. GS-R-1, Legal and Governmental Infrastructure for Nuclear, Radiation, Radioactive Waste and Transport Safety, for a national regulatory infrastructure to regulate any practice involving radiation sources in medicine, industry, research, agriculture and education. The Safety Guide provides advice on the legislative basis for establishing regulatory bodies, including the effective independence of the regulatory body. It also provides guidance on implementing the functions and activities of regulatory bodies: the development of regulations and guides on radiation safety; implementation of a system for notification and authorization; carrying out regulatory inspections; taking necessary enforcement actions; and investigating accidents and circumstances potentially giving rise to accidents. The various aspects relating to the regulatory control of consumer products are explained, including justification, optimization of exposure, safety assessment and authorization. Guidance is also provided on the organization and staffing of regulatory bodies. Contents: 1. Introduction; 2. Legal framework for a regulatory infrastructure; 3. Principal functions and activities of the regulatory body; 4. Regulatory control of the supply of consumer products; 5. Functions of the regulatory body shared with other governmental agencies; 6. Organization and staffing of the regulatory body; 7. Documentation of the functions and activities of the regulatory body; 8. Support services; 9. Quality management for the regulatory system.

  5. 22 CFR 96.39 - Information disclosure and quality control practices.

    Science.gov (United States)

    2010-04-01

    ... 22 Foreign Relations 1 2010-04-01 2010-04-01 false Information disclosure and quality control... for Convention Accreditation and Approval Information Disclosure, Fee Practices, and Quality Control Policies and Practices § 96.39 Information disclosure and quality control practices. (a) The agency or...

  6. Synthetic aperture controlled source electromagnetics

    NARCIS (Netherlands)

    Fan, Y.; Snieder, R.; Slob, E.; Hunziker, J.W.; Singer, J.; Sheiman, J.; Rosenquist, M.

    2010-01-01

    Controlled?source electromagnetics (CSEM) has been used as a de?risking tool in the hydrocarbon exploration industry. Although there have been successful applications of CSEM, this technique is still not widely used in the industry because the limited types of hydrocarbon reservoirs CSEM can detect.

  7. Establishing control over nuclear materials and radiation sources in Georgia

    International Nuclear Information System (INIS)

    Basilia, G.

    2010-01-01

    Regulatory control over radiation sources in Georgia was lost after disintegration of the Soviet Union. A number of radiation accidents and illegal events occurred in Georgia. From 1999 Nuclear and Radiation Safety Service of the Ministry of Environmental Protection and Natural Resources is responsible for regulatory control over radiation sources in Georgia. US NRC Regulatory Assistance Program in Georgia Assist the Service in establishing long term regulatory control over sources. Main focuses of US NRC program are country-wide inventory, create National Registry of sources, safe storage of disused sources, upgrade legislation and regulation, implementation licensing and inspection activities

  8. CLS A Fully Open-Source Control System

    CERN Document Server

    Matias, Elder; Johnson, Terry; Tanner, Robby; Wilson, Tony; Wright, Glen; Zhang, Hao

    2005-01-01

    The Canadian Light Source is one of the first major accelerator facility to adopt a fully open source control system. The control system is based on Experimental Physics and Industrial Control System (EPICS) in use at may other facilities. From the outset CLS utilised RTEMS and Linux as the underlying operating systems for real-time control computers, operator interface computers and servers. When communicating with PLC and other intelligent devices CLS has also adopted a policy of using open communications protocols where possible. Combined these strategies have lead to a system that can easily evolve over the life of the facility without being tied to specific hardware or software suppliers. The operational experience over the past few years has indicates the selected architecture is sufficiently robust and reliable.

  9. Parsing pyrogenic polycyclic aromatic hydrocarbons: forensic chemistry, receptor models, and source control policy.

    Science.gov (United States)

    O'Reilly, Kirk T; Pietari, Jaana; Boehm, Paul D

    2014-04-01

    A realistic understanding of contaminant sources is required to set appropriate control policy. Forensic chemical methods can be powerful tools in source characterization and identification, but they require a multiple-lines-of-evidence approach. Atmospheric receptor models, such as the US Environmental Protection Agency (USEPA)'s chemical mass balance (CMB), are increasingly being used to evaluate sources of pyrogenic polycyclic aromatic hydrocarbons (PAHs) in sediments. This paper describes the assumptions underlying receptor models and discusses challenges in complying with these assumptions in practice. Given the variability within, and the similarity among, pyrogenic PAH source types, model outputs are sensitive to specific inputs, and parsing among some source types may not be possible. Although still useful for identifying potential sources, the technical specialist applying these methods must describe both the results and their inherent uncertainties in a way that is understandable to nontechnical policy makers. The authors present an example case study concerning an investigation of a class of parking-lot sealers as a significant source of PAHs in urban sediment. Principal component analysis is used to evaluate published CMB model inputs and outputs. Targeted analyses of 2 areas where bans have been implemented are included. The results do not support the claim that parking-lot sealers are a significant source of PAHs in urban sediments. © 2013 SETAC.

  10. CDC Best Practices for Comprehensive Tobacco Control Programs - 2007

    Data.gov (United States)

    U.S. Department of Health & Human Services — Centers for Disease Control and Prevention (CDC). Best Practices for Comprehensive Tobacco Control Programs. Funding. CDC's Best Practices for Comprehensive Tobacco...

  11. CDC Best Practices for Comprehensive Tobacco Control Programs - 2014

    Data.gov (United States)

    U.S. Department of Health & Human Services — Centers for Disease Control and Prevention (CDC). Best Practices for Comprehensive Tobacco Control Programs. Funding. CDC's Best Practices for Comprehensive Tobacco...

  12. Effective regulatory control of radioactive sources

    International Nuclear Information System (INIS)

    Meserve, R.A.

    2001-01-01

    This paper provides an overview of the situation in the USA regarding government control over use of radiation sources, the challenges it faces and the potential paths to their resolution. In the light of the large number of radiation sources in use worldwide, the safety record on balance is remarkably good. But there is still considerable room for improvement. The IAEA has an important role to play, and it is playing it effectively

  13. Model Predictive Control of Z-source Neutral Point Clamped Inverter

    DEFF Research Database (Denmark)

    Mo, Wei; Loh, Poh Chiang; Blaabjerg, Frede

    2011-01-01

    This paper presents Model Predictive Control (MPC) of Z-source Neutral Point Clamped (NPC) inverter. For illustration, current control of Z-source NPC grid-connected inverter is analyzed and simulated. With MPC’s advantage of easily including system constraints, load current, impedance network...... response are obtained at the same time with a formulated Z-source NPC inverter network model. Operation steady state and transient state simulation results of MPC are going to be presented, which shows good reference tracking ability of this method. It provides new control method for Z-source NPC inverter...

  14. Redatuming controlled-source electromagnetic data using Stratton–Chu type integral transformations

    DEFF Research Database (Denmark)

    Zhdanov, Michael; Cai, Hongzhu

    2016-01-01

    We present a new method of analyzing controlled-source electromagnetic (CSEM) data based on redatuming of the observed data from the actual receivers into the virtual receivers. We use the Stratton–Chu type integral transform to calculate the EM field in the virtual receivers. The virtual receivers...... can be placed at any desirable position, including close to the target, which increases the sensitivity of the EM data to the target. The developed method provides an effective model-based interpolation/extrapolation tool for electromagnetic field data. This paper demonstrates that redatuming can...... be used for designing the optimized CSEM survey configuration. The numerical examples, for the Kevin Dome Electromagnetic Project Site, illustrate the practical effectiveness of the developed method....

  15. A regional protocol for evaluating the effectiveness of forestry best management practices at controlling erosion and sedimentation

    Science.gov (United States)

    Roger Ryder; Pamela Edwards; Pamela Edwards

    2006-01-01

    Forestry operations do not have permitting requirements under the Clean Water Act because there is a ccsilvicultural exemption" given in that law, as long as best management practices (BMPs) are used to help control non-point source pollution. However, states' monitoring of BMP effectiveness often has been sporadic and anecdotal, and the procedures used have...

  16. Sources of Knowledge and Barriers of Implementing Evidence-Based Practice Among Mental Health Nurses in Saudi Arabia.

    Science.gov (United States)

    Hamaideh, Shaher H

    2017-07-01

    The purposes of this study were to identify the sources of knowledge for nursing practices and to identify the barriers of using "evidence-based practice" (EBP). Descriptive cross-sectional design was used to collect data from 164 Saudi mental health nurses by completing the Development of Evidence-Based Practice Questionnaire. The most frequently used sources of knowledge were relied on social interactions and the nurses' own experiences, while the least frequently used sources were external sources of knowledge and research evidences. Insufficient time to find research reports, difficulty in understanding research reports, and insufficient resources for evidences were the barriers of using EBP. The organizations should encourage using EBP by providing adequate time, resources, knowledge, and skills for mental health nurses through conducting workshops and mentoring. © 2016 Wiley Periodicals, Inc.

  17. Control for nuclear thermionic power source

    International Nuclear Information System (INIS)

    Fletcher, J.C.; Sawyer, C.D.

    1978-01-01

    A control for a power source is described which includes nuclear fuel interspersed with thermionic converters, including a power regulator that maintains a substantially constant output voltage to a variable load, and a control circuit that drives a neutron flux regulator in accordance with the current supplied to the power regulator and the neutron flux density in the region of the converters. The control circuit generates a control signal which is the difference between the neutron flux density and a linear fucntion of the current, and which drives the neutron regulator in a direction to decrease or increase the neutron flux according to the polarity of the control signal

  18. Regulatory control and challenges in Medical facilities using ionising radiation sources

    International Nuclear Information System (INIS)

    Agarwal, S.P.

    2008-01-01

    Medical facilities utilising ionising radiation sources for diagnostic and treatment of cancer are regulated under the provisions of Atomic Energy (Radiation Protection) Rules, 2004 promulgated under the Atomic Energy Act 1962. The Competent Authority for the enforcement of the rules is Chairman, Atomic Energy Regulatory Board (AERB). Practice specific codes are issued by AERB for medical facilities such as Radiotherapy, Nuclear Medicine and Radiology. Regulatory process for control of medical facilities covers the entire life cycle of the radiation sources in three stages viz pre-Iicensing, during useful life and decommissioning and disposal. Pre-Iicensing requirements include use of type approved sources and equipment, approval of design layout of the facility and installation, exclusive (safe and secure) source storage facility when the equipment is not in use, radiation (area/individual) monitoring devices, qualified, trained and certified manpower, emergency response plans and commitment from the licensee for the safe disposal of disused/decayed sources. Compliance to these requirements makes the applicant eligible to obtain license from AERB for the operation of the medical facility. During the use of radiation sources, specific prior approval of the Competent Authority is required in respect of every source replacement, sale, transfer, transport, import and export. Further, all licensees are required to send the periodic safety Status reports to AERB as well as reporting of any off normal events. AERB conducts inspection of the facilities to ensure compliance with the safety requirements during operation of the facility. Violation of safety norms by licensee attracts enforcement action which includes suspension, modification or withdrawal of licensee for operation of the facility. Upon completion of the useful life of the source, the licensee decommissions the facility and returns the source to the original supplier. For returning the source, prior

  19. State-of-the-practice and lessons learned on implementing open data and open source policies.

    Science.gov (United States)

    2012-05-01

    This report describes the current government, academic, and private sector practices associated with open data and open source application development. These practices are identified; and the potential uses with the ITS Programs Data Capture and M...

  20. Code of practice for the use of sealed radioactive sources in borehole logging (1998)

    International Nuclear Information System (INIS)

    1989-12-01

    The purpose of this code is to establish working practices, procedures and protective measures which will aid in keeping doses, arising from the use of borehole logging equipment containing sealed radioactive sources, to as low as reasonably achievable and to ensure that the dose-equivalent limits specified in the National Health and Medical Research Council s radiation protection standards, are not exceeded. This code applies to all situations and practices where a sealed radioactive source or sources are used through wireline logging for investigating the physical properties of the geological sequence, or any fluids contained in the geological sequence, or the properties of the borehole itself, whether casing, mudcake or borehole fluids. The radiation protection standards specify dose-equivalent limits for two categories: radiation workers and members of the public. 3 refs., tabs., ills

  1. CLOSED LOOP CONTROL OF EMBEDDED Z-SOURCE INVERTER WITH FUZZY CONTROLLER FOR SOLAR PV APPLICATIONS

    OpenAIRE

    Midde Mahesh*, K. Leleedhar Rao

    2017-01-01

    This paper proposes the use of Embedded Z –source inverter system with fuzzy controller for Solar Photo Voltaic (PV) applications with adjustable speed drives. Closed loop operation FUZZY control strategies of EZSI system are proposed. EZSI produces the same voltage gain as Z-source inverter (ZSI) but due to the DC sources embedded within the X- shaped impedance network, it has the added advantage of inherent source filtering capability and also reduced capacitor sizing. This can be achiev...

  2. Control of radioisotopes and radiation sources in Indonesia

    International Nuclear Information System (INIS)

    Ridwan, M.

    2001-01-01

    Radioisotopes and radiation sources are extensively used in Indonesia in medicine, industry, mining, agriculture and research. These materials are controlled by the regulatory authority, according to established legal procedures. The Nuclear Energy Control Board of Indonesia (BAPETEN), which was established in 1998 through the Nuclear Energy Act No. 10/1997, is entrusted with the control of any application of nuclear energy, including the application of radioisotopes and radiation sources, through regulation, licensing and inspection. The control is aimed to assure welfare, security and peace, the safety and health of workers and the public, and environmental protection. The number of licences issued to date is around 2400, consisting of 1600 licences for radioisotopes and radiation sources used in hospitals, 347 in radiography, 256 in industry, 53 in mining, and the rest in many other areas such as research and agriculture. A licence can cover one or more radioisotopes or radiation sources, depending on the location of the user institution. These radioisotopes and radiation sources are Co-60, Cs-137, Ir-192, Ra-226, Am-241, Sr-90, Kr-85, Pm-147, linear accelerator and X-ray, and short half-life radioisotopes such as I-125, I-131 and Tc-99m. There are 10 LINACs, 27 X-ray medicines, 61 radioisotope devices for Co-60 and Cs-137, and 10 mHDR Ir-192 for therapeutic purposes currently used in Indonesia and some Ra-226 in storage. Any activity related to the application of nuclear energy is required to be conducted in a manner which observes safety and security. According to the legal requirements, each user has to employ at least one radiation safety officer. To improve the control of the application of radiation sources and radioactive material in the country, BAPETEN introduced some new approaches to the users, including regular dialogues with radiation safety officers and the management of the users, requalification for radiation protection officers twice in five

  3. Orphan sources: Consequences, regaining control and learning the lessons

    International Nuclear Information System (INIS)

    Croft, J.R.

    2001-01-01

    The safety and security record of technologies that use radiation sources is adequate in most cases, but on occasions there has been a lack of appropriate controls or circumvention of those that exist, leading to radiological accidents. Particular concern rise those radiation sources that have become orphans i.e. sources that were never subject to regulatory control, or were abandoned, lost or misplaced, stolen, or removed without authorisation. These sources are likely to be found in the public domain; examples include sources that used in radiotherapy units which have been unintentionally sold as scrap metal and melted thereafter, or which have been found by unsuspecting individuals or stolen, causing serious radiation exposure of people and contamination of the human habitat

  4. The regulatory control of radioactive sources in Argentina

    International Nuclear Information System (INIS)

    Rojkind, Roberto Hector

    1997-01-01

    Argentina has been conducting nuclear activities for more than forty years, and as early as in 1956 established a Regulatory Authority. Procedures for compliance monitoring and enforcement have been in use in the regulatory control of radioactive sources, and regulatory standards and regulations had been set in Argentina, before the accident in Goiania. The conclusions drawn from that accident encouraged in Argentina the improvement of some regulatory procedures and helped to enhance the quality of the regulatory process. Therefore, the effectiveness of the control of spent radioactive sources has gradually increased, and enforcement actions to prevent radioactive sources ending up in the public domain improved. Some lessons learned in Argentina from the accident in Goiania and the main characteristics of an effective enforcement program helpful to prevent radiological accidents in industrial, medical, research and teaching uses of radioactive sources are presented. (author)

  5. Practical Implementations of Advanced Process Control for Linear Systems

    DEFF Research Database (Denmark)

    Knudsen, Jørgen K . H.; Huusom, Jakob Kjøbsted; Jørgensen, John Bagterp

    2013-01-01

    This paper describes some practical problems encountered, when implementing Advanced Process Control, APC, schemes on linear processes. The implemented APC controllers discussed will be LQR, Riccati MPC and Condensed MPC controllers illustrated by simulation of the Four Tank Process and a lineari......This paper describes some practical problems encountered, when implementing Advanced Process Control, APC, schemes on linear processes. The implemented APC controllers discussed will be LQR, Riccati MPC and Condensed MPC controllers illustrated by simulation of the Four Tank Process...... on pilot plant equipment on the department of Chemical Engineering DTU Lyngby....

  6. Effective Regulatory Control of Radioactive Sources in Taiwan

    International Nuclear Information System (INIS)

    Liu, W.; Yuan, C.; Fan, S.; Su, S.

    2004-01-01

    Since the incident of radioactively contaminated buildings first surfaced in Taiwan in 1992, efforts have been made by AEC (Atomic Energy Council) of Taiwan to prevent recurrence of similar incidents involving radioactive materials and to achieve effective regulatory control over radioactive sources. The most important milestone is when AEC began to enforce IRPA he Ionizing Radiation Protection Act with the promulgation of 18 relevant regulations on Feb. 1, 2003. In order to enhance accountability of radioactive material and equipment capable of producing ionizing radiation, AEC develops and begins implementing a RPCS Radiation Protection Control System which is a powerful tool in controlling radiation safety and security. In addition, AEC develops a monthly registration program via internet, an o n-line reporting system f or owners/operators of radioactive sources, to improve monitoring of sealed sources (in-use and not-in-use). The registration requirement applies to 469 licensees possessing about 3,000 sealed sources in Taiwan. Because of the threat of orphan sources, AEC has made great efforts in preventing their contamination of construction steel material by establishing and enforcing the RPMMPIRCB Regulation for Preventive Measures and Management Plans for Incident of Radioactively Contaminated Buildings. To comply with this regulation, all 19 of Taiwan's steel factories with melting furnace have installed portal-type radiation detection system to monitor incoming scrap metal. (Author)

  7. The regulatory control of radioactive sources in Argentina

    International Nuclear Information System (INIS)

    Rojkind, R.H.

    1998-01-01

    Argentina has been conducting nuclear activities for more than forty years, and had established a Regulatory Authority as early as in 1956. Procedures for compliance monitoring and enforcement have been in use in the regulatory control of radioactive sources, and regulatory standards and regulations were in force in Argentina before the accident in Goiania. The conclusions drawn from the Goiania accident encouraged the Argentine authorities to improve some regulatory procedures and helped to enhance the quality of the regulatory process. As a result, the effectiveness of the control of spent radioactive sources has gradually increased, and enforcement actions to prevent radioactive sources ending up in the public domain have improved. Lessons learned in Argentina from the accident in Goiania are presented as well as the main characteristics of an effective enforcement programme to prevent radiological accidents when radioactive sources are used for industrial, medical, research and teaching purposes. (author)

  8. Regulatory control of radiation sources in Slovakia

    International Nuclear Information System (INIS)

    Auxtova, L.

    2001-01-01

    In Slovakia, there are two regulatory authorities. Regulatory control of the utilization of nuclear energy, based on the Slovak National Council's law No. 130/1998 on the peaceful uses of nuclear energy, is exercised by the Nuclear Regulatory Authority of the Slovak Republic. The second regulatory authority - the Ministry of Health - is empowered by law No. 72/1994 on the protection of human health to license radiation sources and is responsible for radiation protection supervision (there are nearly 3000 establishments with sealed sources, radiation generators and unsealed sources in Slovakia). Pursuant to a new radiation protection regulation based on international standards, radiation sources are to be categorized in six classes according to the associated exposure and contamination hazards. A national strategy for improving the safety of radiation sources over their life-cycle and for the management of disused and orphan sources is being prepared for governmental approval. (author)

  9. Radiation practices and regulatory control

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-06-01

    The general principles to be observed in the regulatory control of ionizing radiation use and practices are specified in the guide. It also takes into account of additions and alterations needed for for compliance with the European Union (EU) directives that have not been mentioned in other STUK/ST-guides. (6 refs.).

  10. Radiation practices and regulatory control

    International Nuclear Information System (INIS)

    1997-01-01

    The general principles to be observed in the regulatory control of ionizing radiation use and practices are specified in the guide. It also takes into account of additions and alterations needed for for compliance with the European Union (EU) directives that have not been mentioned in other STUK/ST-guides. (6 refs.)

  11. The regulatory control of radioactive sources in Argentina

    Energy Technology Data Exchange (ETDEWEB)

    Rojkind, Roberto Hector [Autoridade Regulatoria Nuclear, Buenos Aires (Argentina)

    1997-12-31

    Argentina has been conducting nuclear activities for more than forty years, and as early as in 1956 established a Regulatory Authority. Procedures for compliance monitoring and enforcement have been in use in the regulatory control of radioactive sources, and regulatory standards and regulations had been set in Argentina, before the accident in Goiania. The conclusions drawn from that accident encouraged in Argentina the improvement of some regulatory procedures and helped to enhance the quality of the regulatory process. Therefore, the effectiveness of the control of spent radioactive sources has gradually increased, and enforcement actions to prevent radioactive sources ending up in the public domain improved. Some lessons learned in Argentina from the accident in Goiania and the main characteristics of an effective enforcement program helpful to prevent radiological accidents in industrial, medical, research and teaching uses of radioactive sources are presented. (author) 9 refs; e-mail: rrojkind at sede.arn.gov.br

  12. A Robust Practical Generalized Predictive Control for BoilerSuper Heater Temperature Control

    OpenAIRE

    Zaki Maki Mohialdeen

    2015-01-01

    A practical method of robust generalized predictive controller (GPC) application is developed using a combination of Ziegler-Nichols type functions relating the GPC controller parameters to a first order with time delay process parameters and a model matching controller. The GPC controller and the model matching controller are used in a master/slave configuration, with the GPC as the master controller and the model matching controller as the slave controlle...

  13. Rate-control algorithms testing by using video source model

    DEFF Research Database (Denmark)

    Belyaev, Evgeny; Turlikov, Andrey; Ukhanova, Anna

    2008-01-01

    In this paper the method of rate control algorithms testing by the use of video source model is suggested. The proposed method allows to significantly improve algorithms testing over the big test set.......In this paper the method of rate control algorithms testing by the use of video source model is suggested. The proposed method allows to significantly improve algorithms testing over the big test set....

  14. [Bibliometric analysis of literature regarding integrated schistosomiasis control strategy with emphasis on infectious source control].

    Science.gov (United States)

    Qian, Yi-Li; Wang, Wei; Hong, Qing-Biao; Liang, You-Sheng

    2014-12-01

    To evaluate the outcomes of implementation of integrated schistosomiasis control strategy with emphasis on infectious source control using a bibliometric method. The literature pertaining to integrated schistosomiasis control strategy with emphasis on infectious source control was retrieved from CNKI, Wanfangdata, VIP, PubMed, Web of Science, BIOSIS and Google Scholar, and a bibliometric analysis of literature captured was performed. During the period from January 1, 2004 through September 30, 2014, a total of 94 publications regarding integrated schistosomiasis control strategy with emphasis on infectious source control were captured, including 78 Chinese articles (82.98%) and 16 English papers (17.02%). The Chinese literature was published in 21 national journals, and Chinese Journal of Schistosomiasis Control had the largest number of publications, consisting of 37.23% of total publications; 16 English papers were published in 12 international journals, and PLoS Neglected Tropical Diseases had the largest number of publications (3 publications). There were 37 affiliations publishing these 94 articles, and National Institute of Parasitic Diseases, Chinese Center for Disease Control and Prevention (16 publications), Anhui Institute of Schistosomiasis Control (12 publications) and Hunan Institute of Schistosomiasis Control (9 publications) ranked top three affiliations in number of publications. A total of 157 persons were co-authored in these 94 publications, and Wang, Zhou and Zhang ranked top 3 authors in number of publications. The integrated schistosomiasis control strategy with emphasis on infectious source control has been widely implemented in China, and the achievements obtained from the implementation of this strategy should be summarized and transmitted internationally.

  15. National strategies for improving control over orphan sources of ionising radiation

    International Nuclear Information System (INIS)

    Nizamska, M.

    2007-01-01

    Since 1989 Bulgaria started reformation of economy sector. Part of this process is the intensive privatisation, as well as in the sited using radioactive materials for different applications - industry, medicine, agriculture, etc. The quick change of property ownership results in difficulties to identify the assessor of radioactive source or material and finally led to appearance of orphan sources. A orphan source is defined as a source that poses sufficient radiological hazard to warrant regulatory control, but which is not under regulatory control because it has never been so, or because it has been abandoned, lost, misplaced, stolen or otherwise transferred without proper authorisation. A face on these problems, Bulgaria is performing a series of measure to improve the control over orphan sources and to strengthening the control over the nuclear and radioactive materials. The report presents briefly this measures. (author)

  16. Characteristics of Health Care Practices and Systems That Excel in Hypertension Control.

    Science.gov (United States)

    Young, An; Ritchey, Matthew D; George, Mary G; Hannan, Judy; Wright, Janet

    2018-06-07

    Approximately 1 in 3 US adults has hypertension, but only half have their blood pressure controlled. We identified characteristics of health care practices and systems (hereinafter practices) effective in achieving control rates at or above 70% by using data collected via applications submitted from April through June 2017 for consideration in the Million Hearts Hypertension Control Challenge. We included 96 practices serving 635,000 patients with hypertension across 34 US states in the analysis. Mean hypertension control rate was 77.1%; 27.1% of practices had a control rate of 80% or greater. Although many practices served large populations with multiple risk factors for uncontrolled hypertension, high control rates were achieved with implementation of evidenced-based strategies.

  17. Traditional vs. Contemporary Management Control Practices for Developing Public Health Policies.

    Science.gov (United States)

    Naranjo-Gil, David; Sánchez-Expósito, María Jesús; Gómez-Ruiz, Laura

    2016-07-14

    Public health policies must address multiple goals and complex community health needs. Recently, management control practices have emerged to provide a broader type of information for evaluating the effectiveness of healthcare policies, and relate activities and processes to multiple strategic outcomes. This study compares the effect of traditional and contemporary management control practices on the achievement of public health policies. It is also analyzed how two different uses of such practices (enabling vs. coercive) facilitate the achievement of public health policies. Relationships are explored using data collected from managers from public health agencies and public hospitals in Spain. The findings show that contemporary management control practices are more suitable than traditional practices to achieve public health policies. Furthermore, results show that public health policies are better achieved when managers use management control practices in an enabling way rather than in a coercive way.

  18. Femtosecond Light Source for Phase-Controlled Multiphoton Ionization

    International Nuclear Information System (INIS)

    Sokolov, A. V.; Walker, D. R.; Yavuz, D. D.; Yin, G. Y.; Harris, S. E.

    2001-01-01

    We describe a femtosecond Raman light source with more than an octave of optical bandwidth. We use this source to demonstrate phase control of multiphoton ionization under conditions where ionization requires eleven photons of the lowest frequency of the spectrum or five photons of the highest frequency. The nonlinearity of the photoionization process allows us to characterize the light source. Experiment-to-theory comparison implies generation of a near single-cycle waveform

  19. Field Operations and Enforcement Manual for Air Pollution Control. Volume II: Control Technology and General Source Inspection.

    Science.gov (United States)

    Weisburd, Melvin I.

    The Field Operations and Enforcement Manual for Air Pollution Control, Volume II, explains in detail the following: technology of source control, modification of operations, particulate control equipment, sulfur dioxide removal systems for power plants, and control equipment for gases and vapors; inspection procedures for general sources, fuel…

  20. Open source drug discovery in practice: a case study.

    Science.gov (United States)

    Årdal, Christine; Røttingen, John-Arne

    2012-01-01

    Open source drug discovery offers potential for developing new and inexpensive drugs to combat diseases that disproportionally affect the poor. The concept borrows two principle aspects from open source computing (i.e., collaboration and open access) and applies them to pharmaceutical innovation. By opening a project to external contributors, its research capacity may increase significantly. To date there are only a handful of open source R&D projects focusing on neglected diseases. We wanted to learn from these first movers, their successes and failures, in order to generate a better understanding of how a much-discussed theoretical concept works in practice and may be implemented. A descriptive case study was performed, evaluating two specific R&D projects focused on neglected diseases. CSIR Team India Consortium's Open Source Drug Discovery project (CSIR OSDD) and The Synaptic Leap's Schistosomiasis project (TSLS). Data were gathered from four sources: interviews of participating members (n = 14), a survey of potential members (n = 61), an analysis of the websites and a literature review. Both cases have made significant achievements; however, they have done so in very different ways. CSIR OSDD encourages international collaboration, but its process facilitates contributions from mostly Indian researchers and students. Its processes are formal with each task being reviewed by a mentor (almost always offline) before a result is made public. TSLS, on the other hand, has attracted contributors internationally, albeit significantly fewer than CSIR OSDD. Both have obtained funding used to pay for access to facilities, physical resources and, at times, labor costs. TSLS releases its results into the public domain, whereas CSIR OSDD asserts ownership over its results. Technically TSLS is an open source project, whereas CSIR OSDD is a crowdsourced project. However, both have enabled high quality research at low cost. The critical success factors appear to be clearly

  1. A Modified Droop Control Method for Parallel-Connected Current Source Inverters

    DEFF Research Database (Denmark)

    Wei, Baoze; Guerrero, Josep M.; Quintero, Juan Carlos Vasquez

    2016-01-01

    In this paper, a novel control method was proposed for current source inverters under the grid-connected working mode. The control scheme is based on a modified droop control method, with an additional current reference signal that will be generated instead of the voltage reference. Hence......, there is only a current control loop with droop control in the whole control scheme without voltage control loop. So it is very suitable for grid-connected current source inverter which will simplify the design of the control scheme and combine the advantage of droop control. The parallel configuration...... is widely used to acquire high power demand, but the circulating current problem is a key issue that should be considered. In this paper, a simulation based on parallel current source inverters using the proposed control scheme is provided. Simulation results showed that a good circulating current...

  2. 238Pu sources for cardiac pacemakers. II. Control

    International Nuclear Information System (INIS)

    Pottier, R.; Merigot, S.

    1976-01-01

    The method and the apparatus used for thermal (power) and radioactive control of radioisotopic sources for pacemakers are briefly described. The cybernetic system is also presented, which assumes almost automatically the monitoring of control, mechanical and electronic works, data processing, the measurements and computations, and the works related to quality control [fr

  3. Generalized space vector control for current source inverters and rectifiers

    Directory of Open Access Journals (Sweden)

    Roseline J. Anitha

    2016-06-01

    Full Text Available Current source inverters (CSI is one of the widely used converter topology in medium voltage drive applications due to its simplicity, motor friendly waveforms and reliable short circuit protection. The current source inverters are usually fed by controlled current source rectifiers (CSR with a large inductor to provide a constant supply current. A generalized control applicable for both CSI and CSR and their extension namely current source multilevel inverters (CSMLI are dealt in this paper. As space vector pulse width modulation (SVPWM features the advantages of flexible control, faster dynamic response, better DC utilization and easy digital implementation it is considered for this work. This paper generalizes SVPWM that could be applied for CSI, CSR and CSMLI. The intense computation involved in framing a generalized space vector control are discussed in detail. The algorithm includes determination of band, region, subregions and vectors. The algorithm is validated by simulation using MATLAB /SIMULINK for CSR 5, 7, 13 level CSMLI and for CSR fed CSI.

  4. Survey of licensee control room habitability practices

    International Nuclear Information System (INIS)

    Boland, J.F.; Brookshire, R.L.; Danielson, W.F.; Driscoll, J.W.; Graham, E.D.; McConnell, R.J.; Thompson, V.N.

    1985-04-01

    This document presents the results of a survey of Licensee control-room-habitability practices. The survey is part of a comprehensive program plan instituted in August 1983 by the NRC to respond to ongoing questions from the Advisory Committee on Reactor Safeguards (ACRS). The emphasis of this survey was to determine by field review the control-room habitability practices at three different plants, one of which is still under construction and scheduled to receive an operating license in 1986. The other two plants are currently operating, having received operating licenses in the mid-1970's and early 1980's. The major finding of this survey is that despite the fact that the latest control-room-habitability systems have become larger and more complex than earlier systems surveyed, the latest systems do not appear to be functionally superior. The major recommendation of this report is to consolidate into a single NRC document, based upon a comprehensive systems engineering approach, the pertinent criteria for control-room-habitability design

  5. Optimization and control of a small angle ion source using an adaptive neural network controller

    Energy Technology Data Exchange (ETDEWEB)

    Brown, S.K.; Mead, W.C.; Bowling, P.S.; Jones, R.D.; Barnes, C.W.

    1993-09-01

    This project developed an automated controller based on an artificial neural network and evaluated its applicability in a real-time environment. This capability was developed within the context of a small angle negative ion source on the Discharge Test Stand at Los Alamos. The controller processes information obtained from the beam current waveform, developing a figure of merit (fom) to determine the ion source operating conditions. The fom is composed of the magnitude of the beam current, the stability of operation, and the quietness of the beam. Using no knowledge of operating conditions, the controller begins by making of rough scan of the four-dimensional operating surface. This surface uses as independent variables the anode and cathode temperatures, the hydrogen flow rate, and the arc voltage. `Me dependent variable is the fom described above. Once the rough approximation of the surface has been determined, the network formulates a model from which it determines the best operating point. The controller takes the ion source to that operating point for a reality check. As real data is fed in, the model of the operating surface is updated until the neural network`s model agrees with reality. The controller then uses a gradient ascent method to optimize the operation of the ion source. Initial tests of the controller indicate that it is remarkably capable. It has optimized the operation of the ion source on six different occasions bringing the beam to excellent quality and stability.

  6. Categorization of radiation sources

    International Nuclear Information System (INIS)

    Antonova, M.

    2000-01-01

    Through one-parameter (factor) analysis it is proved a hypothesis that the value of a radiation source (RS) activity of an application correlates with the category (the rank) given to it by the IAEA categorization although it is based on other parameters of the RS applications (practices like devices with radiation sources in industry, science, medicine and agriculture). The principles of the new IAEA categorization, taking into account the potential harm the sources may cause and the necessary regulatory control, are described. (author)

  7. Regulatory control of radiation sources in the Philippines

    Energy Technology Data Exchange (ETDEWEB)

    Daroy, Rosita R

    1996-12-31

    This paper is concerned with the radiation protection and safety infrastructure providing emphasis on the regulation and control of radiation sources in the Philippines. It deals with the experiences of the Philippine Nuclear Research Institute, as a regulatory body, in the regulation and control of radioactive materials in radiotherapy, nuclear medicine, industrial radiography, industrial gauges, industrial irradiators, and well logging. This paper includes an inventory of the sources and types of devices/equipment used by licensed users of radioactive materials in the Philippines as a contribution to the data base being prepared by the IAEA. The problems encountered by the regulatory body in the licensing and enforcement process, as well as the lessons learned from incidents involving radioactive materials are discussed. Plans for improving compliance to the regulations and enhancing the effectiveness of PNRI`s regulatory functions are presented. (author). Paper presented during the IAEA Regional (RCA) Workshop on System of Notification, Registration, Licensing, and Control of Radiation Sources and Installations, Jakarta, Indonesia, 24-28 April 1995. 6 refs., 2 figs., 12 tabs.

  8. The use of prisoners as sources of organs--an ethically dubious practice.

    Science.gov (United States)

    Caplan, Arthur

    2011-10-01

    The movement to try to close the ever-widening gap between demand and supply of organs has recently arrived at the prison gate. While there is enthusiasm for using executed prisoners as sources of organs, there are both practical barriers and moral concerns that make it unlikely that proposals to use prisoners will or should gain traction. Prisoners are generally not healthy enough to be a safe source of organs, execution makes the procurement of viable organs difficult, and organ donation post-execution ties the medical profession too closely to the act of execution.

  9. Declaration of input sources in scientific research: should this practice be incorporated to organizational information management?

    Directory of Open Access Journals (Sweden)

    José Osvaldo De Sordi

    Full Text Available This research studies the declaration of input sources for research in scientific communications, more specifically, whether this practice of the academy may be considered a good example to be followed by organizations. Seven hypotheses address two dimensions of input sources: origin (primary or secondary and nature (data or information. It appears that the declaration of research inputs in the academy is problematic, mostly incomplete or inaccurate. This does not reduce the importance of this practice; it simply indicates that the academy should not be considered a privileged space, with wide dominance and practice excellence. Nevertheless, the information environment of organizations can learn and benefit from the experience of the scientific academy. From the analyses of the research sample, a set of procedures has been developed, which allowed organizational analysts and researchers to elaborate a complete and accurate analysis of the input sources to be declared in organizational or scientific communication.

  10. Financial Information Source, Knowledge, and Practices of College Students from Diverse Backgrounds

    Science.gov (United States)

    Mimura, Yoko; Koonce, Joan; Plunkett, Scott W.; Pleskus, Lindsey

    2015-01-01

    Using cross-sectional data, we examined the financial information sources, financial knowledge, and financial practices of young adults, many of whom are first generation college students, ethnic minorities, and immigrants or children of immigrants. Participants (n = 1,249) were undergraduate students at a large regional comprehensive university.…

  11. Computer aided control of the Bonn Penning polarized ion source

    International Nuclear Information System (INIS)

    He, N.W.; VonRossen, P.; Eversheim, P.D.; Busch, R.

    1984-01-01

    A CBM computer system is described which has been set up to control the Bonn Polarized Ion Source. The controlling program, besides setting and logging parameters, performs an optimization of the ion source output. A free definable figure of merit, being composed of the current of the ionizer and its variance, has proven to be an effective means in directing the source optimization. The performance that has been reached during the first successful tests is reported

  12. Practical astronomy in Indo-Persian sources

    Science.gov (United States)

    Ansari, S. M. R.

    In the classical survey of zij literature (by E. Kennedy, 1956), out of 220 listed zijes only three zijes compiled in India are mentioned. They are: Zij-i Jami', ca 1461/62 (Kennedy serial No. X220); Zij-i Shahjahani, ca 1610 (X204); Zij-i Muhammad Shahi, ca 1730 (X203). However, since that classical survey, a number of Indian zijes have been found to be extant. They are: Zij-i Nasiri (ca 1260), Zij-i Nizami (ca 1780), Zij-i Hindi (1805), Zij-i 'Alami (ca 1808), Zij-i Ashki (1816), Zij-i Safdari (1819), Zij-i Sulayman Jahi (1830) and Zij-i Bahadur Khani (1838). It is well known that a zij comprises astronomical-mathematical and also astrological tables for use in practical or observational astronomy. From the standpoint of applied astronomy, it consists of particularly eclipse tables, visibility tables - for lunar crescent, apparitions and disappearances of planets - geographical and star tables. Evidently, this tabulated material can be used for the studies in applied astronomy. Besides zijes, we find also other classes of literature in which are treated the observations of comets, fireballs and meteorites. They are treatises on atmospheric phenomena (Athar-i 'Ulawi), chronicles and histories of Medieval India in Persian. For instance, we have histories by Abul Fadl and 'Arif Qandhari (16-17th c.), al-Husayni (18th c.), to name just a few. In this paper, we describe briefly the above-mentioned Indo-Persian sources, list the various celestial phenomena along with their short account as given in these sources, particularly in the Indian zijes. Finally, we make some remarks about their use in applied astronomy.

  13. Control strategy and experimental study on a novel defrosting method for air-source heat pump

    International Nuclear Information System (INIS)

    Liang Caihua; Zhang Xiaosong; Li Xiuwei; Chen Zhenqian

    2010-01-01

    A new defrosting method - the sensible heat defrosting method, aiming at shelving the various disadvantages of the conventional reverse cycle defrosting was proposed in this paper. The mechanism and process of this method was analysed. To guarantee the reliability, the self-organizing control algorithm with self-learning function was introduced based on the cardinal fuzzy control algorithm. Moreover, the control strategy was enacted; the corresponding self-organizing fuzzy control system was developed; the Micro Controller Unit (MCU) based control unit was accomplished; and the experimental study was conducted to investigate the sample machine of air-source heat pump system. The results of the experiments showed that the self-organizing control algorithm has good control characteristic and effect. On one hand, the adverse shock from the conventional reverse cycle defrosting to the refrigeration system could be avoided through this proposed method; on the other hand, the 'oil rush' could also be eliminated. Besides, the thermal comfort could be greatly improved since the temperature fluctuation range of the supplied water is narrowed by applying this new method in practice.

  14. The Forest Ranger Revisited: A Study of Control Practices and Identification.

    Science.gov (United States)

    Bullis, Connie A.; Tompkins, Phillip K.

    1989-01-01

    Examines change in the United States Forest Service, an organization lauded for its ability to control members through its culture. Describes current control practices, and field tests three theoretical claims regarding unobtrusive control. Finds that control practices have changed from more unobtrusive to more obtrusive. Illustrates the pragmatic…

  15. Belief Control Practices and Organizational Performances: A Survey ...

    African Journals Online (AJOL)

    Belief Control Practices and Organizational Performances: A Survey of Sugar Industry in Kenya. ... employees in the company core values and design of strategic control systems to cope with changing internal and external operating business ...

  16. Establishment of a Practical Approach for Characterizing the Source of Particulates in Water Distribution Systems

    Directory of Open Access Journals (Sweden)

    Seon-Ha Chae

    2016-02-01

    Full Text Available Water quality complaints related to particulate matter and discolored water can be troublesome for water utilities in terms of follow-up investigations and implementation of appropriate actions because particulate matter can enter from a variety of sources; moreover, physicochemical processes can affect the water quality during the purification and transportation processes. The origin of particulates can be attributed to sources such as background organic/inorganic materials from water sources, water treatment plants, water distribution pipelines that have deteriorated, and rehabilitation activities in the water distribution systems. In this study, a practical method is proposed for tracing particulate sources. The method entails collecting information related to hydraulic, water quality, and structural conditions, employing a network flow-path model, and establishing a database of physicochemical properties for tubercles and slimes. The proposed method was implemented within two city water distribution systems that were located in Korea. These applications were conducted to demonstrate the practical applicability of the method for providing solutions to customer complaints. The results of the field studies indicated that the proposed method would be feasible for investigating the sources of particulates and for preparing appropriate action plans for complaints related to particulate matter.

  17. Internal quality control: best practice.

    Science.gov (United States)

    Kinns, Helen; Pitkin, Sarah; Housley, David; Freedman, Danielle B

    2013-12-01

    There is a wide variation in laboratory practice with regard to implementation and review of internal quality control (IQC). A poor approach can lead to a spectrum of scenarios from validation of incorrect patient results to over investigation of falsely rejected analytical runs. This article will provide a practical approach for the routine clinical biochemistry laboratory to introduce an efficient quality control system that will optimise error detection and reduce the rate of false rejection. Each stage of the IQC system is considered, from selection of IQC material to selection of IQC rules, and finally the appropriate action to follow when a rejection signal has been obtained. The main objective of IQC is to ensure day-to-day consistency of an analytical process and thus help to determine whether patient results are reliable enough to be released. The required quality and assay performance varies between analytes as does the definition of a clinically significant error. Unfortunately many laboratories currently decide what is clinically significant at the troubleshooting stage. Assay-specific IQC systems will reduce the number of inappropriate sample-run rejections compared with the blanket use of one IQC rule. In practice, only three or four different IQC rules are required for the whole of the routine biochemistry repertoire as assays are assigned into groups based on performance. The tools to categorise performance and assign IQC rules based on that performance are presented. Although significant investment of time and education is required prior to implementation, laboratories have shown that such systems achieve considerable reductions in cost and labour.

  18. Study on upgrade on nuclear control related open source information website

    International Nuclear Information System (INIS)

    Kim, H. T.; Park, S. S.; Park, W. S.; Choi, Y. M.

    2002-01-01

    The open source information relevant to the nuclear control is regularly collected, analyzed, and published to the three web sites by the Technology Center for Nuclear Control (TCNC) of the Korea Atomic Energy Research Institute (KAERI). These web sites are world-wide, KAERI-wide, and TCNC-wide, respectively. We are to upgrade the KAERI-wide website to the access-controlled world-wide web site with some additional functionality. In this research, the current status of the three nuclear control related open source information websites managed by the TCNC was introduced and methods for upgrading the KAERI-wide open source information website and associated information security technology were reviewed

  19. Control systems for power electronics a practical guide

    CERN Document Server

    Patil, Mahesh

    2015-01-01

    The scope of the book covers most of the aspects as a primer on power electronics starting from a simple diode bridge to a DC-DC convertor using PWM control. The thyristor-bridge and the mechanism of designing a closed loop system are discussed in chapter one, two and three. The concepts are applied in the fourth chapter as a case study for buck converter which uses MOSFETs as switching devices and the closed loop system is elaborated in the fifth chapter. Chapter six is focused on the embedded system basics and the implementation of controls in the digital domain. Chapter seven is a case study of application of an embedded control system for a DC motor. With this book, the reader will find it easy to work on the practical control systems with microcontroller implementation. The core intent of this book is to help gain an accelerated learning path to practical control system engineering and transform control theory to an implementable control system through electronics. Illustrations are provided for most of...

  20. Energy control of supercapacitor/fuel cell hybrid power source

    International Nuclear Information System (INIS)

    Payman, Alireza; Pierfederici, Serge; Meibody-Tabar, Farid

    2008-01-01

    This paper deals with a flatness based control principle in a hybrid system utilizing a fuel cell as a main power source and a supercapacitor as an auxiliary power source. The control strategy is based on regulation of the dc bus capacitor energy and, consequently, voltage regulation. The proposed control algorithm does not use a commutation algorithm when the operating mode changes with the load power variation and, thus, avoids chattering effects. Using the flatness based control method, the fuel cell dynamic and its delivered power is perfectly controlled, and the fuel cell can operate in a safe condition. In the hybrid system, the supercapacitor functions during transient energy delivery or during energy recovery situations. To validate the proposed method, the control algorithms are executed in dSPACE hardware, while analogical current loops regulators are employed in the experimental environment. The experimental results prove the validity of the proposed approach

  1. Anti-Windup Scheme for Practical Control of Positioning Systems

    Directory of Open Access Journals (Sweden)

    Wahyudi Tarig Faisal and Abdulgani Albagul

    2012-10-01

    Full Text Available Positioning systems generally need a good controller to achieve high accuracy, fast response and robustness. In addition, ease of controller design and simplicity of controller structure are very important for practical application.  For satisfying these requirements, nominal characteristic trajectory following controller (NCTF has been proposed as a practical point-to-point (PTP positioning control. However, the effect of actuator saturation can not be completely compensated for due to the integrator windup as the plant parameters vary. This paper presents a method to improve the NCTF controller for overcoming the problem of integrator windup using simple and classical tracking anti-windup scheme. The improved NCTF controller is evaluated through simulation using a rotary positioning system. The results show that the improved NCTF controller is adequate to compensate for the effect of integrator windup. Keywords: Positioning, point-to-point, integrator windup, compensation, controller, robustness.

  2. Strengthening the control on radioactive sources - Cernavoda NPP operating experience

    International Nuclear Information System (INIS)

    Daian, I.; Simionov, V.

    2005-01-01

    This paper presents the national legal frame governing the radioactive source management, legislative requirements introduced during last years and current status of controlled radioactive sources program at Cernavoda NPP. Romania has only one nuclear power plant, Cernavoda NPP, equipped with five PHWR - CANDU-6 Canadian type reactors - with a 700 MW(e) gross capacity each, in different implementation stages. The legal representative of the nuclear power production sector in Romania is 'Nuclearelectrica' S.A. National Company (SNN). SNN is a governmental company controlled by the Ministry of Industry and Trade. The company has headquarters in Bucharest and three subsidiaries: - CNE-PROD Cernavoda (CNE-PROD), operating the Cernavoda NPP - Unit 1; - CNE-INVEST Cernavoda, in charge with the completion of Unit 2 and with the preservation of Units 3,4,5; - Nuclear Fuel Plant in Pitesti (FCN). Unit 1 is in commercial operation since December 2, 1996, Unit 2 is under construction (80% completed) and Units 3, 4, 5 are under preservation. The operation of Cernavoda NPP implies use of radioactive sources that may present a significant risk to health, property and the environment when control is lost. Within the last years CNCAN issued new regulations stating clear responsibilities for the different institutions involved in radioactive materials control programs. To manage radioactive sources in a safe way CNE-PROD established and revised the Controlled Radioactive Sources Program, as part of Station Radiation Protection Regulation, ensuring strict recording of the radioactive sources and their usage, ensuring physical and radiological security, protecting the personnel, members of the public and the environment from the hazards of ionizing radiation during the life cycle of the plant, including decommissioning. (authors)

  3. Strengthening the control on radioactive sources - Cernavoda NPP operating experience

    International Nuclear Information System (INIS)

    Daian, I.; Simionov, V.

    2005-01-01

    Full text: This paper presents the national legal frame governing the radioactive source management, legislative requirements introduced during last years and current status of controlled radioactive sources program at Cernavoda NPP. Romania has only one nuclear power plant, Cernavoda NPP, equipped with five PHWR - CANDU-6 Canadian type reactors - with a 700 MW(e) gross capacity each, in different implementation stages. The legal representative of the nuclear power production sector in Romania is 'Nuclearelectrica' S.A. National Company (SNN). SNN is a governmental company controlled by the Ministry of Industry and Trade. The company has headquarters in Bucharest and three subsidiaries: - CNE-PROD Cernavoda (CNE-PROD), operating the Cernavoda NPP - Unit 1; - CNE-INVEST Cernavoda, in charge with the completion of Unit 2 and with the preservation of Units 3,4,5; - Nuclear Fuel Plant in Pitesti (FCN). Unit 1 is in commercial operation since December 2, 1996, Unit 2 is under construction (80% completed) and Units 3, 4, 5 are under preservation. The operation of Cernavoda NPP implies use of radioactive sources that may present a significant risk to health, property and the environment when control is lost. Within the last years CNCAN issued new regulations stating clear responsibilities for the different institutions involved in radioactive materials control programs. To manage radioactive sources in a safe way CNE-PROD established and revised the Controlled Radioactive Sources Program, as part of Station Radiation Protection Regulation, ensuring strict recording of the radioactive sources and their usage, ensuring physical and radiological security, protecting the personnel, members of the public and the environment from the hazards of ionizing radiation during the life cycle of the plant. (authors)

  4. An optical system for controlling ion source parameters

    International Nuclear Information System (INIS)

    Zhang Baifang; Liu Zhenhao; Jiang Yi; Xu Zhengjia

    1999-01-01

    An optical control system used for adjusting the source's parameters of an ion separator is described. There are two slice microcomputers at HV terminal and the ground respectively. These microcomputers communicate each other with the full-duplex mode through two pieces of optical fiber, in which many parameters are time-share transmitted in the form of optical pulse. This system can stabilize the arc current and temperature, adjust and display all parameters and has safe-guard ability. At HV terminal, the optical coupling technique is used for connecting the CPU and the ion source, and at the ground the CPU can communicate with a control microcomputer

  5. Implementation and performance evaluation open-source controller for precision control of gripper

    Science.gov (United States)

    Lee, Seung-Yong; Ham, Un-Hyeong; Park, Young-Woo; Jung, Hak-Sang; Jung, Il-Kyun; Lim, Sun

    2017-12-01

    This paper proposes integrating gripper embedded operating system, which consist of external interface structure for sophisticated gripper control. This system has multiple functions that control the gripping module and measure the pose of the gripper body with respect to contact environment. A controller based on open source only for the gripper is developed and an external communication interface between robot controller and gripper controller is designed. An experimental environment for the fixed-cycle test consists of integrating magic gripper software system and hardware on commercial business. As a result, a deviation is measured approximately 2% and the system were verified for gripper control.

  6. Development of Remote Control and Interlock System for the PEFP Microwave Ion Source

    International Nuclear Information System (INIS)

    Song, Young Gi; Seol, Kyung Tae; Kwon, Hyeok Jung; Jang, Ji Ho; Cho, Yong Sub

    2011-01-01

    The control system for a microwave ion source as an isolated high voltage device is a main part of the PEFP distributed control system. The system is used to control two sets of microwave ion sources, the remote control and the interlock system. A VME system with an embedded Power PC CPU is used as main computer. The VME system is dedicated to control and monitoring of the ion source operation. An isolated control system has been designed and developed for remote control and monitoring of a microwave generator and various power supplies. As the source is placed on high voltage platform, optical fiber isolation has been used between the serial to optical fiber VME I/O board and the control system on the high voltage platform. These are connected through RS232 serial interface. A fast Ethernet is used to communicate between the microwave ion source control system and other control stations in the PEFP control system. EPICS toolkit is adopted to provide network programming and user interface by using EPICS Channel Access (CA)

  7. Reproduction of nearby sound sources using higher-order ambisonics with practical loudspeaker arrays

    DEFF Research Database (Denmark)

    Favrot, Sylvain Emmanuel; Buchholz, Jörg

    2012-01-01

    the impact of two existing and a new proposed regularization function on the reproduced sound fields and on the main auditory cue for nearby sound sources outside the median plane, i.e, low-frequencies interaural level differences (ILDs). The proposed regularization function led to a better reproduction......In order to reproduce nearby sound sources with distant loudspeakers to a single listener, the near field compensated (NFC) method for higher-order Ambisonics (HOA) has been previously proposed. In practical realization, this method requires the use of regularization functions. This study analyzes...... of point source sound fields compared to existing regularization functions for NFC-HOA. Measurements in realistic playback environments showed that, for very close sources, significant ILDs for frequencies above about 250 Hz can be reproduced with NFC-HOA and the proposed regularization function whereas...

  8. Pre-service teachers’ perceived value of general pedagogical knowledge for practice: Relations with epistemic beliefs and source beliefs

    Science.gov (United States)

    Rosman, Tom; Rueß, Julia; Syring, Marcus; Schneider, Jürgen

    2017-01-01

    Pre-service teachers tend to devalue general pedagogical knowledge (GPK) as a valid source for deriving successful teaching practices. The present study investigated beliefs about knowledge sources and epistemic beliefs as predictors for students’ perceived value of GPK. Three pre-registered hypotheses were tested. We expected beliefs that GPK originates from scientific sources to entail a devaluation of GPK (Hypothesis 1). Concerning epistemic beliefs, we expected absolute beliefs to positively, and multiplistic beliefs to negatively predict pre-service teachers’ perceived practical value of GPK (Hypothesis 2). Finally, we expected relationships between epistemic beliefs and pre-service teachers’ perceived practical value of GPK to be confounded by epistemic trustworthiness, perceived topic-specific consistency and topic-specific familiarity (Hypothesis 3). In a study using a split plot design, 365 pre-service teachers were presented with four texts on different educational research topics. For each topic, three text versions were constructed. Even though they were invariant in content, these versions varied in a way that the results were allegedly generated by a practitioner, an expert or by means of a scientific study. Unexpectedly, results showed that research findings allegedly generated by means of a scientific study were associated with a higher perceived value of (topic-specific) GPK for practice (Hypothesis 1). As expected, the perceived value of GPK for practice was predicted by topic-specific multiplism and domain-specific absolutism (Hypothesis 2). These predictive effects were confounded by expertise evaluations of the source and the consistency of prior beliefs with the presented research results (Hypothesis 3). In summary, our results suggest that source beliefs might not be responsible for the devaluation of GPK, but that beliefs on the nature and structure of GPK (i.e., epistemic beliefs) might play an even more important role in this respect

  9. Pre-service teachers' perceived value of general pedagogical knowledge for practice: Relations with epistemic beliefs and source beliefs.

    Science.gov (United States)

    Merk, Samuel; Rosman, Tom; Rueß, Julia; Syring, Marcus; Schneider, Jürgen

    2017-01-01

    Pre-service teachers tend to devalue general pedagogical knowledge (GPK) as a valid source for deriving successful teaching practices. The present study investigated beliefs about knowledge sources and epistemic beliefs as predictors for students' perceived value of GPK. Three pre-registered hypotheses were tested. We expected beliefs that GPK originates from scientific sources to entail a devaluation of GPK (Hypothesis 1). Concerning epistemic beliefs, we expected absolute beliefs to positively, and multiplistic beliefs to negatively predict pre-service teachers' perceived practical value of GPK (Hypothesis 2). Finally, we expected relationships between epistemic beliefs and pre-service teachers' perceived practical value of GPK to be confounded by epistemic trustworthiness, perceived topic-specific consistency and topic-specific familiarity (Hypothesis 3). In a study using a split plot design, 365 pre-service teachers were presented with four texts on different educational research topics. For each topic, three text versions were constructed. Even though they were invariant in content, these versions varied in a way that the results were allegedly generated by a practitioner, an expert or by means of a scientific study. Unexpectedly, results showed that research findings allegedly generated by means of a scientific study were associated with a higher perceived value of (topic-specific) GPK for practice (Hypothesis 1). As expected, the perceived value of GPK for practice was predicted by topic-specific multiplism and domain-specific absolutism (Hypothesis 2). These predictive effects were confounded by expertise evaluations of the source and the consistency of prior beliefs with the presented research results (Hypothesis 3). In summary, our results suggest that source beliefs might not be responsible for the devaluation of GPK, but that beliefs on the nature and structure of GPK (i.e., epistemic beliefs) might play an even more important role in this respect

  10. Pre-service teachers' perceived value of general pedagogical knowledge for practice: Relations with epistemic beliefs and source beliefs.

    Directory of Open Access Journals (Sweden)

    Samuel Merk

    Full Text Available Pre-service teachers tend to devalue general pedagogical knowledge (GPK as a valid source for deriving successful teaching practices. The present study investigated beliefs about knowledge sources and epistemic beliefs as predictors for students' perceived value of GPK. Three pre-registered hypotheses were tested. We expected beliefs that GPK originates from scientific sources to entail a devaluation of GPK (Hypothesis 1. Concerning epistemic beliefs, we expected absolute beliefs to positively, and multiplistic beliefs to negatively predict pre-service teachers' perceived practical value of GPK (Hypothesis 2. Finally, we expected relationships between epistemic beliefs and pre-service teachers' perceived practical value of GPK to be confounded by epistemic trustworthiness, perceived topic-specific consistency and topic-specific familiarity (Hypothesis 3. In a study using a split plot design, 365 pre-service teachers were presented with four texts on different educational research topics. For each topic, three text versions were constructed. Even though they were invariant in content, these versions varied in a way that the results were allegedly generated by a practitioner, an expert or by means of a scientific study. Unexpectedly, results showed that research findings allegedly generated by means of a scientific study were associated with a higher perceived value of (topic-specific GPK for practice (Hypothesis 1. As expected, the perceived value of GPK for practice was predicted by topic-specific multiplism and domain-specific absolutism (Hypothesis 2. These predictive effects were confounded by expertise evaluations of the source and the consistency of prior beliefs with the presented research results (Hypothesis 3. In summary, our results suggest that source beliefs might not be responsible for the devaluation of GPK, but that beliefs on the nature and structure of GPK (i.e., epistemic beliefs might play an even more important role in this

  11. Open Source Drug Discovery in Practice: A Case Study

    Science.gov (United States)

    Årdal, Christine; Røttingen, John-Arne

    2012-01-01

    Background Open source drug discovery offers potential for developing new and inexpensive drugs to combat diseases that disproportionally affect the poor. The concept borrows two principle aspects from open source computing (i.e., collaboration and open access) and applies them to pharmaceutical innovation. By opening a project to external contributors, its research capacity may increase significantly. To date there are only a handful of open source R&D projects focusing on neglected diseases. We wanted to learn from these first movers, their successes and failures, in order to generate a better understanding of how a much-discussed theoretical concept works in practice and may be implemented. Methodology/Principal Findings A descriptive case study was performed, evaluating two specific R&D projects focused on neglected diseases. CSIR Team India Consortium's Open Source Drug Discovery project (CSIR OSDD) and The Synaptic Leap's Schistosomiasis project (TSLS). Data were gathered from four sources: interviews of participating members (n = 14), a survey of potential members (n = 61), an analysis of the websites and a literature review. Both cases have made significant achievements; however, they have done so in very different ways. CSIR OSDD encourages international collaboration, but its process facilitates contributions from mostly Indian researchers and students. Its processes are formal with each task being reviewed by a mentor (almost always offline) before a result is made public. TSLS, on the other hand, has attracted contributors internationally, albeit significantly fewer than CSIR OSDD. Both have obtained funding used to pay for access to facilities, physical resources and, at times, labor costs. TSLS releases its results into the public domain, whereas CSIR OSDD asserts ownership over its results. Conclusions/Significance Technically TSLS is an open source project, whereas CSIR OSDD is a crowdsourced project. However, both have enabled high quality

  12. Regulatory Control of Radiation Sources. Safety Guide (Arabic Edition)

    International Nuclear Information System (INIS)

    2012-01-01

    This Safety Guide is intended to assist States in implementing the requirements established in Safety Standards Series No. GS-R-1, Legal and Governmental Infrastructure for Nuclear, Radiation, Radioactive Waste and Transport Safety, for a national regulatory infrastructure to regulate any practice involving radiation sources in medicine, industry, research, agriculture and education. The Safety Guide provides advice on the legislative basis for establishing regulatory bodies, including the effective independence of the regulatory body. It also provides guidance on implementing the functions and activities of regulatory bodies: the development of regulations and guides on radiation safety; implementation of a system for notification and authorization; carrying out regulatory inspections; taking necessary enforcement actions; and investigating accidents and circumstances potentially giving rise to accidents. The various aspects relating to the regulatory control of consumer products are explained, including justification, optimization of exposure, safety assessment and authorization. Guidance is also provided on the organization and staffing of regulatory bodies. Contents: 1. Introduction; 2. Legal framework for a regulatory infrastructure; 3. Principal functions and activities of the regulatory body; 4. Regulatory control of the supply of consumer products; 5. Functions of the regulatory body shared with other governmental agencies; 6. Organization and staffing of the regulatory body; 7. Documentation of the functions and activities of the regulatory body; 8. Support services; 9. Quality management for the regulatory system.

  13. The advanced light source control system

    International Nuclear Information System (INIS)

    Magyary, S.; Chin, M.; Cork, C.; Fahmie, M.; Lancaster, H.; Molinari, P.; Ritchie, A.; Robb, A.; Timossi, C.; Young, J.

    1990-01-01

    The criteria for the design of a modern control system are discussed in the context of the special requirements for the control of the Advanced Light Source (ALS). This is followed by the description of the system being built, which has a number of special features. The emphasis has been placed on providing an extremely wide I/O and CPU bandwidth (greater than 120 Mbits/s and 1200 Mips, respectively) and on using commercially available hardware and software. The only major custom design item is the Intelligent Local Controller (ILC), of which about 600 will be used to interface to the hardware. The use of personal computers for the operator stations allows the use of a wealth of industrial standards for windows, languages and tools. (orig.)

  14. Revised accident source terms and control room habitability

    International Nuclear Information System (INIS)

    Lahti, G.P.; Hubner, R.S.; Johnson, W.J.; Schwartz, B.C.

    1993-01-01

    In April 1992, the NRC staff presented to the Commissioners the draft NUREG open-quotes Revised Accident Source Terms for Light-Water Nuclear Power Plants.close quotes This document is the culmination of more than ten years of NRC-sponsored research and represents the first change in the NRC's position on source terms since TID-14844 was issued in 1962. The purpose of this paper is to investigate the impact of the revised source terms on the current approach to analyzing control room habitability as required by 10 CFR 50. Sample calculations are presented that identify aspects of the model requiring clarification before the implementation of the revised source terms. 6 refs., 4 tabs

  15. A Look at the Future of Controlled-Source Seismology

    Science.gov (United States)

    Keller, G. R.; Klemperer, S.; Hole, J.; Snelson, C.

    2008-12-01

    Facilities like EarthScope and IRIS/PASSCAL offer a framework in which to re-assess the role of our highest- resolution geophysical tool, controlled-source seismology. This tool is effective in near surface studies that focus on the upper 100 m of the crust to studies that focus on Moho structure and the lithospheric mantle. IRIS has now existed for over two decades and has transformed the way in which passive-source seismology in particular is carried out. Progress over these two decades has led to major discoveries about continental architecture and evolution through the development of three-dimensional images of the upper mantle and lithosphere. Simultaneously the hydrocarbon exploration industry has mapped increasingly large fractions of our sedimentary basins in three-dimensions and at unprecedented resolution and fidelity. Thanks to the additional instruments in the EarthScope facility, a clear scientific need and opportunity exists to map, at similar resolution, all of the crust - the igneous/metamorphic basement, the non-petroliferous basins that contain the record of continental evolution, and the seismogenic faults and active volcanoes that are the principal natural hazards we face. Controlled-source seismology remains the fundamental technology behind exploration for all fossil fuels and many water resources, and as such is a multi-billion-dollar industry centered in the USA. Academic scientists are leaders in developing the algorithms to process the most advanced industry data, but lack the academic data sets to which to apply this technology. University and government controlled-source seismologists, and their students who will populate the exploration industry, are increasingly divorced from that industry by their reliance on sparse spatial recording of usually only a single-component of the wavefield, generated by even sparser seismic sources. However, if we can find the resources, the technology now exists to provide seismic images of immense

  16. Power Controllability of Three-phase Converter with Unbalanced AC Source

    DEFF Research Database (Denmark)

    Ma, Ke; Liserre, Marco; Blaabjerg, Frede

    2013-01-01

    Three-phase DC-AC power converters suffer from power oscillation and overcurrentt problems in case of unbalanced AC source voltage that can be caused by grid/generator faults. Existing solutions to handle these problems are properly selecting and controlling the positive and negative sequence...... currents. In this work a new series of control strategies which utilize the zero-sequence components are proposed to enhance the power control ability under this adverse conditions. It is concluded that by introducing proper zero sequence current controls and corresponding circuit configurations, the power...... converter can enable more flexible control targets, achieving better performances in the delivered power and load current when suffering from unbalanced AC sources....

  17. Theory Interpretation of Control System and Design Practice

    International Nuclear Information System (INIS)

    Jung, Heon Sul

    2003-11-01

    This book tells of theory interpretation of control system and design practice using automatic balancing weighing machine , including what control is, basic use of CEM Tool such as summary, work environment of CEM Tool, Symbol of CEM Tool, instruction of CEM Tool, drawing graph, and practice of making of CEM Tool, basic use of SIM Tool, driving test of sensor measurement motor such as LED, Pulse pick-up, answer test of RC circuit, structure of balancing weighing machine and wheel mathematical model, analysis of time response and frequency response of balancing weighing machine, and mathematical model and material property of balancing weighing machine.

  18. Modeling generalized interline power-flow controller (GIPFC using 48-pulse voltage source converters

    Directory of Open Access Journals (Sweden)

    Amir Ghorbani

    2018-05-01

    Full Text Available Generalized interline power-flow controller (GIPFC is one of the voltage-source controller (VSC-based flexible AC transmission system (FACTS controllers that can independently regulate the power-flow over each transmission line of a multiline system. This paper presents the modeling and performance analysis of GIPFC based on 48-pulsed voltage-source converters. This paper deals with a cascaded multilevel converter model, which is a 48-pulse (three levels voltage source converter. The voltage source converter described in this paper is a harmonic neutralized, 48-pulse GTO converter. The GIPFC controller is based on d-q orthogonal coordinates. The algorithm is verified using simulations in MATLAB/Simulink environment. Comparisons between unified power flow controller (UPFC and GIPFC are also included. Keywords: Generalized interline power-flow controller (GIPFC, Voltage source converter (VCS, 48-pulse GTO converter

  19. Control of orphan sources. Import to and transport through Slovenia

    International Nuclear Information System (INIS)

    Cesarek, J.; Vokal Nemec, B.

    2007-01-01

    Orphan sources are radioactive sources which are not under regulatory control, either because they have never been under regulatory control, or because they have been abandoned, lost, misplaced, stolen or transferred without proper authorisation. The issue of orphan sources is not a new one but the situation has been highlighted more and more in the last ten years. One of the most important international milestones in this regard was the conference in Dijon, France in 1998. The orphan sources have become an international problem due to steady increase in international trade which made impossible to control every transfer of goods between countries. Shipments of metal scrap, either national or international, could comprise orphan sources which had come into metal stream. The consequences of such events vary greatly: from contaminated metal just above exemption levels to a melting of volatile radionuclides of significant activity which may cause enormous remediation costs. In addition, the phenomenon of deliberate abuse of nuclear material and radioactive material or previous accidents with found orphan sources worldwide and fatalities have made this issue even more provoking. In Slovenia, no such drastic events have occurred so far. Since 1991 there have been a few meltings of cobalt-60 sources with only economic impact. On several occasions, Italy - the country with strict import control - has detected elevated radiation and denied shipments of scrap metal. They had originated either from Slovenia or from other countries, mostly from former Yugoslav republics. The Slovenian experience shows that majority of cases is related to import of scrap metal in Slovenia or to transit of such material through Slovenia. These orphan sources have originated from past industrial activities or have been under no or weak regulatory control in their countries of origin. In order to prevent inadvertent movement and illicit trafficking of nuclear material and radioactive sources some

  20. Rainfall Deduction Method for Estimating Non-Point Source Pollution Load for Watershed

    OpenAIRE

    Cai, Ming; Li, Huai-en; KAWAKAMI, Yoji

    2004-01-01

    The water pollution can be divided into point source pollution (PSP) and non-point source pollution (NSP). Since the point source pollution has been controlled, the non-point source pollution is becoming the main pollution source. The prediction of NSP load is being increasingly important in water pollution controlling and planning in watershed. Considering the monitoring data shortage of NPS in China, a practical estimation method of non-point source pollution load --- rainfall deduction met...

  1. A Survey of Open-Source UAV Flight Controllers and Flight Simulators

    DEFF Research Database (Denmark)

    Ebeid, Emad Samuel Malki; Skriver, Martin; Terkildsen, Kristian Husum

    2018-01-01

    , which are all tightly linked to the UAV flight controller hardware and software. The lack of standardization of flight controller architectures and the use of proprietary closed-source flight controllers on many UAV platforms, however, complicates this work: solutions developed for one flight controller...... may be difficult to port to another without substantial extra development and testing. Using open-source flight controllers mitigates some of these challenges and enables other researchers to validate and build upon existing research. This paper presents a survey of the publicly available open...

  2. Funding source and research report quality in nutrition practice-related research.

    Directory of Open Access Journals (Sweden)

    Esther F Myers

    Full Text Available BACKGROUND: The source of funding is one of many possible causes of bias in scientific research. One method of detecting potential for bias is to evaluate the quality of research reports. Research exploring the relationship between funding source and nutrition-related research report quality is limited and in other disciplines the findings are mixed. OBJECTIVE: The purpose of this study is to determine whether types of funding sources of nutrition research are associated with differences in research report quality. DESIGN: A retrospective study of research reporting quality, research design and funding source was conducted on 2539 peer reviewed research articles from the American Dietetic Association's Evidence Analysis Library® database. RESULTS: Quality rating frequency distributions indicate 43.3% of research reports were rated as positive, 50.1% neutral, and 6.6% as negative. Multinomial logistic regression results showed that while both funding source and type of research design are significant predictors of quality ratings (χ2 = 118.99, p≤0.001, the model's usefulness in predicting overall research report quality is little better than chance. Compared to research reports with government funding, those not acknowledging any funding sources, followed by studies with University/hospital funding were more likely to receive neutral vs positive quality ratings, OR = 1.85, P <0.001 and OR = 1.54, P<0.001, respectively and those that did not report funding were more likely to receive negative quality ratings (OR = 4.97, P<0.001. After controlling for research design, industry funded research reports were no more likely to receive a neutral or negative quality rating than those funded by government sources. CONCLUSION: Research report quality cannot be accurately predicted from the funding source after controlling for research design. Continued vigilance to evaluate the quality of all research regardless of the funding source

  3. Study on road surface source pollution controlled by permeable pavement

    Science.gov (United States)

    Zheng, Chaocheng

    2018-06-01

    The increase of impermeable pavement in urban construction not only increases the runoff of the pavement, but also produces a large number of Non-Point Source Pollution. In the process of controlling road surface runoff by permeable pavement, a large number of particulate matter will be withheld when rainwater is being infiltrated, so as to control the source pollution at the source. In this experiment, we determined the effect of permeable road surface to remove heavy pollutants in the laboratory and discussed the related factors that affect the non-point pollution of permeable pavement, so as to provide a theoretical basis for the application of permeable pavement.

  4. A source-controlled data center network model.

    Science.gov (United States)

    Yu, Yang; Liang, Mangui; Wang, Zhe

    2017-01-01

    The construction of data center network by applying SDN technology has become a hot research topic. The SDN architecture has innovatively separated the control plane from the data plane which makes the network more software-oriented and agile. Moreover, it provides virtual multi-tenancy, effective scheduling resources and centralized control strategies to meet the demand for cloud computing data center. However, the explosion of network information is facing severe challenges for SDN controller. The flow storage and lookup mechanisms based on TCAM device have led to the restriction of scalability, high cost and energy consumption. In view of this, a source-controlled data center network (SCDCN) model is proposed herein. The SCDCN model applies a new type of source routing address named the vector address (VA) as the packet-switching label. The VA completely defines the communication path and the data forwarding process can be finished solely relying on VA. There are four advantages in the SCDCN architecture. 1) The model adopts hierarchical multi-controllers and abstracts large-scale data center network into some small network domains that has solved the restriction for the processing ability of single controller and reduced the computational complexity. 2) Vector switches (VS) developed in the core network no longer apply TCAM for table storage and lookup that has significantly cut down the cost and complexity for switches. Meanwhile, the problem of scalability can be solved effectively. 3) The SCDCN model simplifies the establishment process for new flows and there is no need to download flow tables to VS. The amount of control signaling consumed when establishing new flows can be significantly decreased. 4) We design the VS on the NetFPGA platform. The statistical results show that the hardware resource consumption in a VS is about 27% of that in an OFS.

  5. A source-controlled data center network model

    Science.gov (United States)

    Yu, Yang; Liang, Mangui; Wang, Zhe

    2017-01-01

    The construction of data center network by applying SDN technology has become a hot research topic. The SDN architecture has innovatively separated the control plane from the data plane which makes the network more software-oriented and agile. Moreover, it provides virtual multi-tenancy, effective scheduling resources and centralized control strategies to meet the demand for cloud computing data center. However, the explosion of network information is facing severe challenges for SDN controller. The flow storage and lookup mechanisms based on TCAM device have led to the restriction of scalability, high cost and energy consumption. In view of this, a source-controlled data center network (SCDCN) model is proposed herein. The SCDCN model applies a new type of source routing address named the vector address (VA) as the packet-switching label. The VA completely defines the communication path and the data forwarding process can be finished solely relying on VA. There are four advantages in the SCDCN architecture. 1) The model adopts hierarchical multi-controllers and abstracts large-scale data center network into some small network domains that has solved the restriction for the processing ability of single controller and reduced the computational complexity. 2) Vector switches (VS) developed in the core network no longer apply TCAM for table storage and lookup that has significantly cut down the cost and complexity for switches. Meanwhile, the problem of scalability can be solved effectively. 3) The SCDCN model simplifies the establishment process for new flows and there is no need to download flow tables to VS. The amount of control signaling consumed when establishing new flows can be significantly decreased. 4) We design the VS on the NetFPGA platform. The statistical results show that the hardware resource consumption in a VS is about 27% of that in an OFS. PMID:28328925

  6. Code of practice for the safe use of ionizing radiation in secondary schools (1986)

    International Nuclear Information System (INIS)

    1987-01-01

    The code of practice is intended for schools and indicates the basic philosophy behind the current approach to the control of hazards associated with the use of ionizing radiation. The purpose of this code is to provide guidance on safe and proper practices in the use of radiation. It covers modes of radiation exposure, shielding, dose limits, responsibility, general rules, x-ray generators, general control of radioactive sources, sealed sources and unsealed sources

  7. Operational experience of SST1 NBI control system with prototype Ion source

    International Nuclear Information System (INIS)

    Patel, V B; Patel, P J; Singh, N P; Tripathi, V; Thakkar, D; Gupta, L N; Prahlad, V; Sharma, S K; Bandyopadyay, M; Chakraborty, A K; Baruah, U K; Mattoo, S K; Patel, G B; Onali, Raja

    2010-01-01

    This paper presents operational experience of integrated control of the arc-filament and High-voltage power supply of Steady State Tokamak (SST)-1 NBI system using Versa Module Europa (VME) system on prototype Ion source. The control algorithm is implemented on the VxWorks operating system using 'C' language. This paper also describes the operating sequence and controls on power supply system. Discharge and Filament power supplies are controlled in such a way so that necessary discharge current can be available in Ion Source. The discharge current is controlled by manipulating the filament current. Close loop control is implemented on each filament power supply with feedback from Discharge Current to control the overall discharge inside the ion source. Necessary actions for shut OFF and subsequent Turn ON are also taken during breakdowns between the Grids of the ion source. Total numbers of breakdowns are also monitored. Shot is terminated, if the breakdown count is higher than the set value. This control system can be programmed to restart High-voltage power supply within 5mS after breakdown occurs. This control system is capable to handle the all types of dynamics in the system. This paper also presents results of experiment.

  8. Infrastructure of Taiwan photon source control network

    International Nuclear Information System (INIS)

    Chang, Y.T.; Kuo, C.H.; Cheng, Y.S.; Jenny Chen; Hsu, S.Y.; Wu, C.Y.; Hu, K.H.; Hsu, K.T.

    2012-01-01

    A reliable, flexible and secure network is essential for the Taiwan Photon Source (TPS) control system which is based upon the EPICS tool-kit framework. Subsystem sub-nets will connect to control system via EPICS based CA gateways for forwarding data and reducing network traffic. Combining cyber security technologies such as fire-wall, NAT and VLAN, control network is isolated to protect IOCs and accelerator components. Network management tools are used to improve network performance. Remote access mechanism will be constructed for maintenance and troubleshooting. The Ethernet is also used as field-bus for instruments such as power supplies. This paper will describe the system architecture for the TPS control network. Cabling topology, redundancy and maintainability are also discussed. (authors)

  9. A quality control program for radiation sources

    International Nuclear Information System (INIS)

    Almeida, C.E. de; Sibata, C.H.; Cecatti, E.R.; Kawakami, N.S.; Alexandre, A.C.; Chiavegatti Junior, M.

    1982-01-01

    An extensive quality control program was established covering the following areas: physical parameters of the therapeutical machines, dosimetric standards, preventive maintenance of radiation sources and measuring instruments. A critical evaluation of this program was done after two years (1977-1979) of routine application and the results will be presented. The fluctuation on physical parameters strongly supports the efforts and cost of a quality control program. This program has certainly improved the accuracy required on the delivery of the prescribed dose for radiotherapy treatment. (Author) [pt

  10. Estimation of the Plant Time Constant of Current-Controlled Voltage Source Converters

    DEFF Research Database (Denmark)

    Vidal, Ana; Yepes, Alejandro G.; Malvar, Jano

    2014-01-01

    Precise knowledge of the plant time constant is essential to perform a thorough analysis of the current control loop in voltage source converters (VSCs). As the loop behavior can be significantly influenced by the VSC working conditions, the effects associated to converter losses should be included...... in the model, through an equivalent series resistance. In a recent work, an algorithm to identify this parameter was developed, considering the inductance value as known and practically constant. Nevertheless, the plant inductance can also present important uncertainties with respect to the inductance...... of the VSC interface filter measured at rated conditions. This paper extends that method so that both parameters of the plant time constant (resistance and inductance) are estimated. Such enhancement is achieved through the evaluation of the closed-loop transient responses of both axes of the synchronous...

  11. Re-skilling the social practices: open source and life-towards a commons-based peer production in agro-biotechnology?

    Science.gov (United States)

    Nicolosi, Guido; Ruivenkamp, Guido

    2013-09-01

    Inspired by the thinking of authors such as Andrew Feenberg, Tim Ingold and Richard Sennett, this article sets forth substantial criticism of the 'social uprooting of technology' paradigm, which deterministically considers modern technology an autonomous entity, independent and indifferent to the social world (practices, skills, experiences, cultures, etc.). In particular, the authors' focus on demonstrating that the philosophy,methodology and experience linked to open source technological development represent an emblematic case of re-encapsulation of the technical code within social relations (reskilling practices). Open source is discussed as a practice, albeit not unique, of community empowerment aimed at the participated and shared rehabilitation of technological production ex-ante. Furthermore, the article discusses the application of open source processes in the agro-biotechnological field, showing how they may support a more democratic endogenous development, capable of binding technological innovation to the objectives of social (reducing inequalities) and environmental sustainability to a greater degree.

  12. APPLICATION OF CONTROLLED SOURCE AUDIO MAGNETOTELLURIC (CSAMT AT GEOTHERMAL

    Directory of Open Access Journals (Sweden)

    Susilawati S.

    2017-04-01

    Full Text Available CSAMT or Controlled Source Audio-Magnetotelluric is one of the Geophysics methods to determine the resistivity of rock under earth surface. CSAMT method utilizes artificial stream and injected into the ground, the frequency of artificial sources ranging from 0.1 Hz to 10 kHz, CSAMT data source effect correction is inverted. From the inversion results showed that there is a layer having resistivity values ranged between 2.5 Ω.m – 15 Ω.m, which is interpreted that the layer is clay.

  13. Source-dependent and source-independent controls on plutonium oxidation state and colloid associations in groundwater.

    Science.gov (United States)

    Buesseler, Ken O; Kaplan, Daniel I; Dai, Minhan; Pike, Steven

    2009-03-01

    Plutonium (Pu) was characterized for its isotopic composition, oxidation states, and association with colloids in groundwater samples near disposal basins in F-Area of the Savannah River Site and compared to similar samples collected six years earlier. Two sources of Pu were identified, the disposal basins, which contained a 24Pu/l39Pu isotopic signature consistent with weapons grade Pu, and 244Cm, a cocontaminant that is a progenitor radionuclide of 24Pu. 24Pu that originated primarily from 244Cm tended to be appreciably more oxidized (Pu(V/VI)), less associated with colloids (approximately 1 kDa - 0.2 microm), and more mobile than 239Pu, as suggested by our prior studies at this site. This is not evidence of isotope fractionation but rather "source-dependent" controls on 240Pu speciation which are processes that are not at equilibrium, i.e., processes that appear kinetically hindered. There were also "source-independent" controls on 239Pu speciation, which are those processes that follow thermodynamic equilibrium with their surroundings. For example, a groundwater pH increase in one well from 4.1 in 1998 to 6.1 in 2004 resulted in an order of magnitude decrease in groundwater 239Pu concentrations. Similarly, the fraction of 239Pu in the reduced Pu(III/IV) and colloidal forms increased systematically with decreases in redox condition in 2004 vs 1998. This research demonstrates the importance of source-dependent and source-independent controls on Pu speciation which would impact Pu mobility during changes in hydrological, chemical, or biological conditions on both seasonal and decadal time scales, and over short spatial scales. This implies more dynamic shifts in Pu speciation, colloids association, and transport in groundwater than commonly believed.

  14. Effects of the airwave in time-domain marine controlled-source electromagnetics

    NARCIS (Netherlands)

    Hunziker, J.W.; Slob, E.C.; Mulder, W.

    2011-01-01

    In marine time-domain controlled-source electromagnetics (CSEM), there are two different acquisition methods: with horizontal sources for fast and simple data acquisition or with vertical sources for minimizing the effects of the airwave. Illustrations of the electric field as a function of space

  15. Radiological control in fires involving radiation sources

    International Nuclear Information System (INIS)

    Franco, J.O.A.; Coelho, C.P.

    1984-01-01

    The copies used during the chatter by techniques from CDTN in the I Mineiro Symposium of Fire Engineering, are presented. The chatter was based on emergency radiation control course, given by CDTN. Basic concepts, such as nuclear physics fundaments, radiation nature and detection, radiation protection and practical aspects of radiological fire emergency, were enphasized. (M.C.K.) [pt

  16. [Source data management in clinical researches].

    Science.gov (United States)

    Ho, Effie; Yao, Chen; Zhang, Zi-bao; Liu, Yu-xiu

    2015-11-01

    Source data and its source documents are the foundation of clinical research. Proper source data management plays an essential role for compliance with regulatory and GCP requirements. Both paper and electronic source data co-exist in China. Due to the increasing use of electronic technology in pharmaceutical and health care industry, electronic data source becomes an upcoming trend with clear advantages. To face new opportunities and to ensure data integrity, quality and traceability from source data to regulatory submission, this document demonstrates important concepts, principles and best practices during managing source data. It includes but not limited to: (1) important concepts of source data (e.g., source data originator, source data elements, source data identifier for audit trail, etc.); (2) various modalities of source data collection in paper and electronic methods (e.g., paper CRF, EDC, Patient Report Outcomes/eCOA, etc.); (3) seven main principles recommended in the aspect of data collection, traceability, quality standards, access control, quality control, certified copy and security during source data management; (4) a life cycle from source data creation to obsolete is used as an example to illustrate consideration and implementation of source data management.

  17. National policy for control of radioactive sources and radioactive waste from non-power applications in Lithuania

    International Nuclear Information System (INIS)

    Klevinskas, G.; Mastauskas, A.

    2001-01-01

    According to the Law on Radiation Protection of the Republic of Lithuania (passed in 1999), the Radiation Protection Centre of the Ministry of Health is the regulatory authority responsible for the radiation protection of public and of workers using sources of ionizing radiation in Lithuania. One of its responsibilities is the control of radioactive sources from the beginning of their 'life cycle', when they are imported in, used, transported and placed as spent into the radioactive waste storage facilities. For the effective control of sources there is national authorization system (notification- registration-licensing) based on the international requirements and recommendations introduced, which also includes keeping and maintaining the Register of Sources, controlling and investigating events while illegally carrying on or in possession of radioactive material, decision making and performing the state radiation protection supervision and control of users of radioactive sources, controlling, within the limits of competence, the radioactive waste management activities in nuclear and non-nuclear power applications. According to the requirements set out in the Law on Radiation Protection and the Government Resolution 'On Establishment of the State Register of the Sources of Ionizing Radiation and Exposure of Workers' (1999) and supplementary legal acts, all licence-holders conducting their activities with sources of ionizing radiation have to present all necessary data to the State Register after annual inventory of sources, after installation of new sources, after decommissioning of sources, after disposal of spent sources, after finishing the activities with the generators of ionizing radiation. The information to the Radiation Protection Centre has to be presented every week from the Customs Department of the Ministry of Finance about all sources of ionizing radiation imported to or exported from Lithuania and the information about the companies performed these

  18. Uniform-related infection control practices of dental students

    Directory of Open Access Journals (Sweden)

    Aljohani Y

    2017-04-01

    Full Text Available Yazan Aljohani,1 Mohammed Almutadares,1 Khalid Alfaifi,1 Mona El Madhoun,1 Maysoon H Albahiti,2 Nadia Al-Hazmi3 1Internship Program, Faculty of dentistry, King Abdulaziz University, 2Department of Endodontics, King Abdulaziz University, 3Department of Oral Biology, King Abdulaziz University, Faculty of Dentistry, Jeddah, Saudi Arabia Background: Uniform-related infection control practices are sometimes overlooked and underemphasized. In Saudi Arabia, personal protective equipment must meet global standards for infection control, but the country’s Islamic legislature also needs to be taken into account. Aim: To assess uniform-related infection control practices of a group of dental students in a dental school in Saudi Arabia and compare the results with existing literature related to cross-contamination through uniforms in the dental field. Method: A questionnaire was formulated and distributed to dental students at King Abdulaziz University Faculty of Dentistry in Jeddah, Saudi Arabia, which queried the students about their uniform-related infection control practices and their methods and frequency of laundering and sanitizing their uniforms, footwear, and name tags. Results: There is a significant difference between genders with regard to daily uniform habits. The frequency of uniform washing was below the standard and almost 30% of students were not aware of how their uniforms are washed. Added to this, there is no consensus on a unified uniform for male and female students. Conclusion: Information on preventing cross-contamination through wearing uniforms must be supplied, reinforced, and emphasized while taking into consideration the cultural needs of the Saudi society. Keywords: cross-contamination, infection control, dental students, uniforms

  19. Problems in the fingerprints based polycyclic aromatic hydrocarbons source apportionment analysis and a practical solution.

    Science.gov (United States)

    Zou, Yonghong; Wang, Lixia; Christensen, Erik R

    2015-10-01

    This work intended to explain the challenges of the fingerprints based source apportionment method for polycyclic aromatic hydrocarbons (PAH) in the aquatic environment, and to illustrate a practical and robust solution. The PAH data detected in the sediment cores from the Illinois River provide the basis of this study. Principal component analysis (PCA) separates PAH compounds into two groups reflecting their possible airborne transport patterns; but it is not able to suggest specific sources. Not all positive matrix factorization (PMF) determined sources are distinguishable due to the variability of source fingerprints. However, they constitute useful suggestions for inputs for a Bayesian chemical mass balance (CMB) analysis. The Bayesian CMB analysis takes into account the measurement errors as well as the variations of source fingerprints, and provides a credible source apportionment. Major PAH sources for Illinois River sediments are traffic (35%), coke oven (24%), coal combustion (18%), and wood combustion (14%). Copyright © 2015. Published by Elsevier Ltd.

  20. Characterizing multi-photon quantum interference with practical light sources and threshold single-photon detectors

    Science.gov (United States)

    Navarrete, Álvaro; Wang, Wenyuan; Xu, Feihu; Curty, Marcos

    2018-04-01

    The experimental characterization of multi-photon quantum interference effects in optical networks is essential in many applications of photonic quantum technologies, which include quantum computing and quantum communication as two prominent examples. However, such characterization often requires technologies which are beyond our current experimental capabilities, and today's methods suffer from errors due to the use of imperfect sources and photodetectors. In this paper, we introduce a simple experimental technique to characterize multi-photon quantum interference by means of practical laser sources and threshold single-photon detectors. Our technique is based on well-known methods in quantum cryptography which use decoy settings to tightly estimate the statistics provided by perfect devices. As an illustration of its practicality, we use this technique to obtain a tight estimation of both the generalized Hong‑Ou‑Mandel dip in a beamsplitter with six input photons and the three-photon coincidence probability at the output of a tritter.

  1. Clinical Practice and Quality Assurance Challenges in Modern Brachytherapy Sources and Dosimetry

    International Nuclear Information System (INIS)

    Butler, Wayne M.; Merrick, Gregory S.

    2008-01-01

    Modern brachytherapy has led to effective treatments through the establishment of broadly applicable dosimetric thresholds for maximizing survival with minimal morbidity. Proper implementation of recent dosimetric consensus statements and quality assurance procedures is necessary to maintain the established level of safety and efficacy. This review classifies issues as either 'systematic' or 'stochastic' in terms of their impact on large groups or individual patients, respectively. Systematic changes affecting large numbers of patients occur infrequently and include changes in source dosimetric parameters, prescribing practice, dose calculation formalism, and improvements in calculation algorithms. The physicist must be aware of how incipient changes accord with previous experience. Stochastic issues involve procedures that are applied to each patient individually. Although ample guidance for quality assurance of brachytherapy sources exists, some ambiguities remain. The latest American Association of Physicists in Medicine guidance clarifies what is meant by independent assay, changes source sampling recommendations, particularly for sources in sterile strands and sterile preassembled needles, and modifies action level thresholds. The changing environment of brachytherapy has not changed the fact that the prime responsibility for quality assurance in brachytherapy lies with the institutional medical physicist

  2. Source to point of use drinking water changes and knowledge, attitude and practices in Katsina State, Northern Nigeria

    Science.gov (United States)

    Onabolu, B.; Jimoh, O. D.; Igboro, S. B.; Sridhar, M. K. C.; Onyilo, G.; Gege, A.; Ilya, R.

    In many Sub-Saharan countries such as Nigeria, inadequate access to safe drinking water is a serious problem with 37% in the region and 58% of rural Nigeria using unimproved sources. The global challenge to measuring household water quality as a determinant of safety is further compounded in Nigeria by the possibility of deterioration from source to point of use. This is associated with the use of decentralised water supply systems in rural areas which are not fully reticulated to the household taps, creating a need for an integrated water quality monitoring system. As an initial step towards establishing the system in the north west and north central zones of Nigeria, The Katsina State Rural Water and Sanitation Agency, responsible for ensuring access to safe water and adequate sanitation to about 6 million people carried out a three pronged study with the support of UNICEF Nigeria. Part 1 was an assessment of the legislative and policy framework, institutional arrangements and capacity for drinking water quality monitoring through desk top reviews and Key Informant Interviews (KII) to ascertain the institutional capacity requirements for developing the water quality monitoring system. Part II was a water quality study in 700 households of 23 communities in four local government areas. The objectives were to assess the safety of drinking water, compare the safety at source and household level and assess the possible contributory role of end users’ Knowledge Attitudes and Practices. These were achieved through water analysis, household water quality tracking, KII and questionnaires. Part III was the production of a visual documentary as an advocacy tool to increase awareness of the policy makers of the linkages between source management, treatment and end user water quality. The results indicate that except for pH, conductivity and manganese, the improved water sources were safe at source. However there was a deterioration in water quality between source and

  3. Plasma control for efficient extreme ultra-violet source

    International Nuclear Information System (INIS)

    Takahashi, Kensaku; Nakajima, Mitsuo; Kawamura, Tohru; Shiho, Makoto; Hotta, Eiki; Horioka, Kazuhiko

    2008-01-01

    To generate a high efficiency extreme-ultraviolet (EUV) source, effects of plasma shape for controlling radiative plasmas based on xenon capillary discharge are experimentally investigated. The radiation characteristics observed via tapered capillary discharge are compared with those of straight one. From the comparison, the long emission period and different plasma behaviors of tapered capillary discharge are confirmed. This means that control of the plasma geometry is effective for prolonging the EUV emission period. This result also indicates that the plasma shape control seems to have a potential for enhancing the conversion efficiency. (author)

  4. Regulatory control of radiation sources in the Philippines

    International Nuclear Information System (INIS)

    Daroy, Rosita R.

    1995-01-01

    This paper is concerned with the radiation protection and safety infrastructure providing emphasis on the regulation and control of radiation sources in the Philippines. It deals with the experiences of the Philippine Nuclear Research Institute, as a regulatory body, in the regulation and control of radioactive materials in radiotherapy, nuclear medicine, industrial radiography, industrial gauges, industrial irradiators, and well logging. This paper includes an inventory of the sources and types of devices/equipment used by licensed users of radioactive materials in the Philippines as a contribution to the data base being prepared by the IAEA. The problems encountered by the regulatory body in the licensing and enforcement process, as well as the lessons learned from incidents involving radioactive materials are discussed. Plans for improving compliance to the regulations and enhancing the effectiveness of PNRI's regulatory functions are presented. (author)

  5. A Practical Study of Control in Objected-Oriented–Functional–Logic Programming with Paisley

    Directory of Open Access Journals (Sweden)

    Baltasar Trancón y Widemann

    2017-01-01

    Full Text Available Paisley is an extensible lightweight embedded domain-specific language for nondeterministic pattern matching in Java. Using simple APIs and programming idioms, it brings the power of functional-logic processing of arbitrary data objects to the Java platform, without constraining the underlying object-oriented semantics. Here we present an extension to the Paisley framework that adds pattern-based control flow. It exploits recent additions to the Java language, namely functional interfaces and lambda expressions, for an explicit and transparent continuation-passing style approach to control. We evaluate the practical impact of the novel features on a real-world case study that reengineers a third-party open-source project to use Paisley in place of conventional object-oriented data query idioms. We find the approach viable for incremental refactoring of legacy code, with significant qualitative improvements regarding separation of concerns, clarity and intentionality, thus making for easier code understanding, testing and debugging.

  6. Infection control practice in private dental laboratories in Riyadh

    International Nuclear Information System (INIS)

    AlKheraif, Abdulaziz A; Mobarak, Fahmy A

    2008-01-01

    In view of the risk of infection of dental health care workers and patients, interruption of possible chains of infection is to be demanded. The objective of this study was to assess infection control practice in private dental laboratories in Riyadh City, Kingdom of Saudi Arabia. The study was conducted on thirty-two private dental laboratories in Riyadh City regarding infection control practiced by these laboratories. The instrument of the study consisted of ten open-ended questions that were asked from the laboratories directors. A large percentage of the surveyed laboratories (87.5 %) did not implement any infection control protocol during their practice. The mean number of impressions received per week was 16. Most of the surveyed laboratories (90.6 %) had no way of communication with the clinics regarding the disinfection procedures. The results indicated that 62.5 % of the laboratories reported that they were aware that they may get infection from non-disinfected items. Only a small percentage (6.2%) of the laboratories added disinfecting agent to pumice slurry. Wearing laboratory coats was reported by 75% of the laboratory workers. The use of gloves during work was reported by 59.3% of the laboratories while 56.2% reported the use protective eyewear. Only 21.8% of the laboratories use face masks during work. Construction of infection control manuals that contain updated and recommended guidelines to ensure aseptic practice in private dental laboratories is highly recommended. Also, a way of communication between dentists and dental technicians regarding disinfection of laboratory items should be strongly encouraged. (author)

  7. Eternal triangle: the interaction of light source, electrical control gear, and optics

    Science.gov (United States)

    S'heeren, Griet

    1998-04-01

    In this particular 'affair' the participants are less than human but have individual personalities they bring to their relationship with each other. High pressure metal halide lamps such as BriteArc lamps have the highest luminance and radiance of all continuously operating practical light source. Since these lamps have short arcs and are available in power ratings from about 30W to 30kW they have found applications with various optical systems. Besides the lamps, such systems include an electrical control device and an optical system. To fulfil the user's requirements for a specific application, it is not only important to choose the right lamp, but crucial to achieve a harmonious marriage between the light source, electrical control device and the optics. To run a high pressure discharge lamp an ignitor/ballast system is essential This stabilizes the lamp parameters. The chemical components inside the lamp determine the lamp voltage and the gear determines, via the current, the lamp power. These are directly related in the luminance and color temperature of the emitted light. Therefore lamp performance and effective life are dependent on the ignitor, control gear and lamp combination. Since the lamp emits radiation in all directions, collection of the light from a lamp can be improved by using reflectors to deliver the light into a lens system. Since lamps with short arc gaps approach a point source they appear ideal for optical system applications. The shape of the reflector and the focusing of the lamp determine which part of the light is collected out of the light-arc. In the case of an LCD projector, the final light output also depends on the transmission characteristics of the LCD panels. Their nonlinearity causes the color of the emitted light to be different from the lamp color. All these parameters have to be optimized to obtain the highest performance. This leads to the conclusion that a carefully matched combination of lamp, ignitor/ballast and optics

  8. 75 FR 63844 - Healthcare Infection Control Practices Advisory Committee (HICPAC)

    Science.gov (United States)

    2010-10-18

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Healthcare...), regarding the practice of healthcare infection control and strategies for surveillance, prevention, and control of healthcare-associated infections (e.g., nosocomial infections), antimicrobial resistance, and...

  9. RCT: Module 2.08, Radiological Source Control, Course 8774

    Energy Technology Data Exchange (ETDEWEB)

    Hillmer, Kurt T. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-08-10

    radioactive source is material used for its emitted radiation. Sources are sealed or unsealed and are classified as accountable or exempt. Radioactive sources are used for response checks, functional checks, and the calibration of instruments and monitors to traceable standards. To ensure the safety and welfare of all personnel, it is important to maintain control of radioactive sources to minimize the potential for the spread of contamination, unnecessary exposure to personnel, loss or theft, and improper disposal. This course will prepare the student with the skills necessary for RCT qualification by passing quizzes, tests, and the RCT Comprehensive Phase 1, Unit 2 Examination (TEST 27566) and will provide in-the-field skills.

  10. Control of radiation sources in Brazil

    International Nuclear Information System (INIS)

    Oliveira, Silvia Maria Velasques de; Menezes, Sergio Ferreira; Alves Filho, Aristeu Dacio; Xavier, Ana Maria

    1997-01-01

    The radiological accident occurred in Goiania, in 1987, brought to light several deficiencies in the conduction of the licensing processes of medical, industrial and research facilities that handle radioisotopes as well as int he control of radioactive sources in Brazil. The objective of this article is to describe some of the technical and administrative measures taken to ensure the adoption of appropriate radiological safety standards throughout the country, thus reducing the incidence of radiological accidents. (author)

  11. [Automatic adjustment control system for DC glow discharge plasma source].

    Science.gov (United States)

    Wan, Zhen-zhen; Wang, Yong-qing; Li, Xiao-jia; Wang, Hai-zhou; Shi, Ning

    2011-03-01

    There are three important parameters in the DC glow discharge process, the discharge current, discharge voltage and argon pressure in discharge source. These parameters influence each other during glow discharge process. This paper presents an automatic control system for DC glow discharge plasma source. This system collects and controls discharge voltage automatically by adjusting discharge source pressure while the discharge current is constant in the glow discharge process. The design concept, circuit principle and control program of this automatic control system are described. The accuracy is improved by this automatic control system with the method of reducing the complex operations and manual control errors. This system enhances the control accuracy of glow discharge voltage, and reduces the time to reach discharge voltage stability. The glow discharge voltage stability test results with automatic control system are provided as well, the accuracy with automatic control system is better than 1% FS which is improved from 4% FS by manual control. Time to reach discharge voltage stability has been shortened to within 30 s by automatic control from more than 90 s by manual control. Standard samples like middle-low alloy steel and tin bronze have been tested by this automatic control system. The concentration analysis precision has been significantly improved. The RSDs of all the test result are better than 3.5%. In middle-low alloy steel standard sample, the RSD range of concentration test result of Ti, Co and Mn elements is reduced from 3.0%-4.3% by manual control to 1.7%-2.4% by automatic control, and that for S and Mo is also reduced from 5.2%-5.9% to 3.3%-3.5%. In tin bronze standard sample, the RSD range of Sn, Zn and Al elements is reduced from 2.6%-4.4% to 1.0%-2.4%, and that for Si, Ni and Fe is reduced from 6.6%-13.9% to 2.6%-3.5%. The test data is also shown in this paper.

  12. Automation system for quality control in manufacture of iodine-125 sealed sources used in brachytherapy

    International Nuclear Information System (INIS)

    Somessari, Samir L.; Feher, Anselmo; Sprenger, Francisco E.; Rostellato, Maria E.C.M.; Moura, Joao A.; Costa, Osvaldo L.; Calvo, Wilson A.P.

    2011-01-01

    The objective of this work is to develop an automation system for Quality Control in the production of Iodine-125 sealed sources, after undergoing the process of laser beam welding. These sources, also known as Iodine-125 seeds are used, successfully, in the treatment of cancer by brachytherapy, with low-dose rates. Each small seed is composed of a welded titanium capsule with 0.8 mm diameter and 4.5 mm in length, containing Iodine-125 adsorbed on an internal silver wire. The seeds are implanted in the human prostate to irradiate the tumor and treat the cancerous cells. The technology to automate the quality control system in the manufacture of Iodine-125 seeds consists in developing and associate mechanical parts, electronic components and pneumatic circuits to control machines and processes. The automation technology for Iodine-125 seed production developed in this work employs programmable logic controller, step motors, drivers of control, electrical-electronic interfaces, photoelectric sensors, interfaces of communication and software development. Industrial automation plays an important role in the production of Iodine-125 seeds, with higher productivity and high standard of quality, facilitating the implementation and operation of processes with good manufacturing practices. Nowadays, the Radiation Technology Center at IPEN-CNEN/SP imports and distributes 36,000 Iodine-125 seeds per year for clinics and hospitals in the whole country. However, the Brazilian potential market is of 8,000 Iodine-125 seeds per month. Therefore, the local production of these radioactive seeds has become a priority for the Institute, aiming to reduce the price and increase the supply to the population in Brazil. (author)

  13. Automation system for quality control in manufacture of iodine-125 sealed sources used in brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Somessari, Samir L.; Feher, Anselmo; Sprenger, Francisco E.; Rostellato, Maria E.C.M.; Moura, Joao A.; Costa, Osvaldo L.; Calvo, Wilson A.P., E-mail: somessar@ipen.b, E-mail: afeher@ipen.b, E-mail: sprenger@ipen.b, E-mail: elisaros@ipen.b, E-mail: olcosta@ipen.b, E-mail: wapcalvo@ipen.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2011-07-01

    The objective of this work is to develop an automation system for Quality Control in the production of Iodine-125 sealed sources, after undergoing the process of laser beam welding. These sources, also known as Iodine-125 seeds are used, successfully, in the treatment of cancer by brachytherapy, with low-dose rates. Each small seed is composed of a welded titanium capsule with 0.8 mm diameter and 4.5 mm in length, containing Iodine-125 adsorbed on an internal silver wire. The seeds are implanted in the human prostate to irradiate the tumor and treat the cancerous cells. The technology to automate the quality control system in the manufacture of Iodine-125 seeds consists in developing and associate mechanical parts, electronic components and pneumatic circuits to control machines and processes. The automation technology for Iodine-125 seed production developed in this work employs programmable logic controller, step motors, drivers of control, electrical-electronic interfaces, photoelectric sensors, interfaces of communication and software development. Industrial automation plays an important role in the production of Iodine-125 seeds, with higher productivity and high standard of quality, facilitating the implementation and operation of processes with good manufacturing practices. Nowadays, the Radiation Technology Center at IPEN-CNEN/SP imports and distributes 36,000 Iodine-125 seeds per year for clinics and hospitals in the whole country. However, the Brazilian potential market is of 8,000 Iodine-125 seeds per month. Therefore, the local production of these radioactive seeds has become a priority for the Institute, aiming to reduce the price and increase the supply to the population in Brazil. (author)

  14. Opioid detoxification : from controlled clinical trial to clinical practice

    NARCIS (Netherlands)

    Dijkstra, Boukje A G; De Jong, Cor A J; Wensing, Michel; Krabbe, Paul F M; van der Staak, Cees P F

    2010-01-01

    Controlled clinical trials have high internal validity but suffer from difficulties in external validity. This study evaluates the generalizability of the results of a controlled clinical trial on rapid detoxification in the everyday clinical practice of two addiction treatment centers. The results

  15. Licensing authority's control of radiation sources and nuclear materials in Brazil

    International Nuclear Information System (INIS)

    Binns, D.A.C.

    2002-01-01

    Full text: The Brazilian Nuclear Energy Commission is the national licensing authority and among its responsibilities is the control of nuclear materials and radiation sources. This control is carried out in three different ways: 1) Control of the import and export of nuclear materials and radiation sources. To be able to import or export any nuclear material or radiation source, the user has to have an explicit permission of the licensing authority. This is controlled by electronic means in which the user has to fill a special form found on the licensing authority's home page, where he has to fill in his name, license number, license number of his radiation protection officer and data of the material to be imported or exported. These data are checked with a data base that contains all the information of the licensed users and qualified personnel before authorization is emitted. The airport authorities have already installed x-ray machines to check all baggages entering or leaving the country. 2) Transport and transfer permit for radiation sources. In order to transport and/or transfer radiations sources and nuclear materials within the country, the user(s) have to submit an application to the licensing authority. The user(s) fill out an application form where he fills in his company's name, licensing I.D., radiation protection officer's name and I.D and identification of the sources involved. These information are checked with the licensing operations data before the operations is permitted. 3) Inspections and radiation monitoring systems. Routine and regulatory inspections are continuously carried out where the user's radiation sources and nuclear materials inventory are checked. Also the physical security and protection of these materials are verified. The installation of monitoring systems is an item that is being discussed with the airport authorities so as to increase the possibilities of detecting any illegal transport of these materials. (author)

  16. Regulatory control of radioactive sources: an international perspective

    International Nuclear Information System (INIS)

    Flakus, F.N.

    1998-01-01

    Within its Regular Programme and its Technical Co-operation Programme, the IAEA undertakes a number of activities in support of national efforts aimed at strengthening national infrastructures for the control of radiation sources. The framework of these activities is described. (author)

  17. Controlled-source seismic interferometry with one way wave fields

    Science.gov (United States)

    van der Neut, J.; Wapenaar, K.; Thorbecke, J. W.

    2008-12-01

    In Seismic Interferometry we generally cross-correlate registrations at two receiver locations and sum over an array of sources to retrieve a Green's function as if one of the receiver locations hosts a (virtual) source and the other receiver location hosts an actual receiver. One application of this concept is to redatum an area of surface sources to a downhole receiver location, without requiring information about the medium between the sources and receivers, thus providing an effective tool for imaging below complex overburden, which is also known as the Virtual Source method. We demonstrate how elastic wavefield decomposition can be effectively combined with controlled-source Seismic Interferometry to generate virtual sources in a downhole receiver array that radiate only down- or upgoing P- or S-waves with receivers sensing only down- or upgoing P- or S- waves. For this purpose we derive exact Green's matrix representations from a reciprocity theorem for decomposed wavefields. Required is the deployment of multi-component sources at the surface and multi- component receivers in a horizontal borehole. The theory is supported with a synthetic elastic model, where redatumed traces are compared with those of a directly modeled reflection response, generated by placing active sources at the virtual source locations and applying elastic wavefield decomposition on both source and receiver side.

  18. 75 FR 3912 - Healthcare Infection Control Practices Advisory Committee (HICPAC)

    Science.gov (United States)

    2010-01-25

    ..., Detection, and Control of Infectious Diseases (NCPDCID), regarding: (1) The practice of hospital infection control; (2) strategies for surveillance, prevention, and control of infections (e.g., nosocomial... healthcare-associated infections Recovery Act efforts; discussion on the draft guideline for prevention of...

  19. Material accountancy and control practice at a research reactor facility

    International Nuclear Information System (INIS)

    Bouchard, J.; Maurel, J.J.; Tromeur, Y.

    1982-01-01

    This session surveys the regulations, organization, and accountancy practice that compose the French State System of Accountancy and Control. Practical examples are discussed showing how inventories are verified at a critical assembly facility and at a materials testing reactor

  20. Health care workers' knowledge, attitudes and practices on tuberculosis infection control, Nepal.

    Science.gov (United States)

    Shrestha, Anita; Bhattarai, Dipesh; Thapa, Barsha; Basel, Prem; Wagle, Rajendra Raj

    2017-11-17

    Infection control remains a key challenge for Tuberculosis (TB) control program with an increased risk of TB transmission among health care workers (HCWs), especially in settings with inadequate TB infection control measures. Poor knowledge among HCWs and inadequate infection control practices may lead to the increased risk of nosocomial TB transmission. An institution-based cross-sectional survey was conducted in 28 health facilities providing TB services in the Kathmandu Valley, Nepal. A total of 190 HCWs were assessed for the knowledge, attitudes and practices on TB infection control using a structured questionnaire. The level of knowledge on TB infection control among almost half (45.8%) of the HCWs was poor, and was much poorer among administration and lower level staff. The knowledge level was significantly associated with educational status, and TB training and/or orientation received. The majority (73.2%) of HCWs had positive attitude towards TB infection control. Sixty-five percent of HCWs were found to be concerned about being infected with TB. Use of respirators among the HCWs was limited and triage of TB suspects was also lacking. Overall knowledge and practices of HCWs on TB infection control were not satisfactory. Effective infection control measures including regular skill-based training and/or orientation for all categories of HCWs can improve infection control practices in health facilities.

  1. An exploratory survey of malaria prevalence and people's knowledge, attitudes and practices of mosquito larval source management for malaria control in western Kenya

    NARCIS (Netherlands)

    Imbahale, S.S.; Fillinger, U.; Githeko, A.; Mukabana, W.R.; Takken, W.

    2010-01-01

    A large proportion of mosquito larval habitats in urban and rural communities in sub-Saharan Africa are man-made. Therefore, community-based larval source management (LSM) could make a significant contribution to malaria control in an integrated vector management approach. Here we implemented an

  2. Controlled trial of pharmacist intervention in general practice: the effect on prescribing costs.

    Science.gov (United States)

    Rodgers, S; Avery, A J; Meechan, D; Briant, S; Geraghty, M; Doran, K; Whynes, D K

    1999-09-01

    It has been suggested that the employment of pharmacists in general practice might moderate the growth in prescribing costs. However, empirical evidence for this proposition has been lacking. We report the results of a controlled trial of pharmacist intervention in United Kingdom general practice. To determine whether intervention practices made savings relative to controls. An evaluation of an initiative set up by Doncaster Health Authority. Eight practices agreed to take part and received intensive input from five pharmacists for one year (September 1996 to August 1997) at a cost of 163,000 Pounds. Changes in prescribing patterns were investigated by comparing these practices with eight individually matched controls for both the year of the intervention and the previous year. Prescribing data (PACTLINE) were used to assess these changes. The measures used to take account of differences in the populations of the practices included the ASTRO-PU for overall prescribing and the STAR-PU for prescribing in specific therapeutic areas. Differences between intervention and control practices were subjected to Wilcoxon matched-pairs, signed-ranks tests. The median (minimum to maximum) rise in prescribing costs per ASTRO-PU was 0.85 Pound (-1.95 Pounds to 2.05 Pounds) in the intervention practices compared with 2.55 Pounds (1.74 Pounds to 4.65 Pounds) in controls (P = 0.025). Had the cost growth of the intervention group been as high as that of the controls, their total prescribing expenditure would have been around 347,000 Pounds higher. This study suggests that the use of pharmacists did control prescribing expenditure sufficiently to offset their employment costs.

  3. Improving low-wage, midsized employers' health promotion practices: a randomized controlled trial.

    Science.gov (United States)

    Hannon, Peggy A; Harris, Jeffrey R; Sopher, Carrie J; Kuniyuki, Alan; Ghosh, Donetta L; Henderson, Shelly; Martin, Diane P; Weaver, Marcia R; Williams, Barbara; Albano, Denise L; Meischke, Hendrika; Diehr, Paula; Lichiello, Patricia; Hammerback, Kristen E; Parks, Malcolm R; Forehand, Mark

    2012-08-01

    The Guide to Community Preventive Services (Community Guide) offers evidence-based intervention strategies to prevent chronic disease. The American Cancer Society (ACS) and the University of Washington Health Promotion Research Center co-developed ACS Workplace Solutions (WPS) to improve workplaces' implementation of Community Guide strategies. To test the effectiveness of WPS for midsized employers in low-wage industries. Two-arm RCT; workplaces were randomized to receive WPS during the study (intervention group) or at the end of the study (delayed control group). Forty-eight midsized employers (100-999 workers) in King County WA. WPS provides employers one-on-one consulting with an ACS interventionist via three meetings at the workplace. The interventionist recommends best practices to adopt based on the workplace's current practices, provides implementation toolkits for the best practices the employer chooses to adopt, conducts a follow-up visit at 6 months, and provides technical assistance. Employers' implementation of 16 best practices (in the categories of insurance benefits, health-related policies, programs, tracking, and health communications) at baseline (June 2007-June 2008) and 15-month follow-up (October 2008-December 2009). Data were analyzed in 2010-2011. Intervention employers demonstrated greater improvement from baseline than control employers in two of the five best-practice categories; implementing policies (baseline scores: 39% program, 43% control; follow-up scores: 49% program, 45% control; p=0.013) and communications (baseline scores: 42% program, 44% control; follow-up scores: 76% program, 55% control; p=0.007). Total best-practice implementation improvement did not differ between study groups (baseline scores: 32% intervention, 37% control; follow-up scores: 39% intervention, 42% control; p=0.328). WPS improved employers' health-related policies and communications but did not improve insurance benefits design, programs, or tracking. Many

  4. System control for the modulated 252Cf source ''Shuffler''

    International Nuclear Information System (INIS)

    Stephens, M.M.

    1975-06-01

    The design and theory of operation of the control chassis for a 252 Cf nondestructive assay system are described. This system repetitively transfers a 252 Cf source from the irradiation region to a shielded position before measuring the delayed neutrons. The design criteria for the system were: rapid movement and precise positioning of the 252 Cf source, precise positioning of the sample, and very accurate timing of the irradiate and count cycles. To achieve these results crystal oscillators were used for timing, and stepping motors were used to position the sample and the source. (U.S.)

  5. Proportional-Resonant Controllers. A New Breed of Controllers Suitable for Grid-Connected Voltage-Source Converters

    DEFF Research Database (Denmark)

    Teodorescu, Remus; Blaabjerg, Frede

    2004-01-01

    This paper is describing the recently introduced proportional-resonant (PR) controllers and their suitability for grid-connected converters current control. It is shown that the known shortcomings associated with PI controllers like steady - state error for single-phase converters and the need...... of decoupling for three-phase converters can be alleviated. Additionally, selective harmonic compensation is also possible with PR controllers. Suggested control-diagrams for three-phase grid converters and active filters are also presented. A practical application of PR current control for a photovoltaic (PV...

  6. Cross-Layer Design of Source Rate Control and Congestion Control for Wireless Video Streaming

    Directory of Open Access Journals (Sweden)

    Peng Zhu

    2007-01-01

    Full Text Available Cross-layer design has been used in streaming video over the wireless channels to optimize the overall system performance. In this paper, we extend our previous work on joint design of source rate control and congestion control for video streaming over the wired channel, and propose a cross-layer design approach for wireless video streaming. First, we extend the QoS-aware congestion control mechanism (TFRCC proposed in our previous work to the wireless scenario, and provide a detailed discussion about how to enhance the overall performance in terms of rate smoothness and responsiveness of the transport protocol. Then, we extend our previous joint design work to the wireless scenario, and a thorough performance evaluation is conducted to investigate its performance. Simulation results show that by cross-layer design of source rate control at application layer and congestion control at transport layer, and by taking advantage of the MAC layer information, our approach can avoid the throughput degradation caused by wireless link error, and better support the QoS requirements of the application. Thus, the playback quality is significantly improved, while good performance of the transport protocol is still preserved.

  7. Open source identity management patterns and practices using OpenAM 10.x

    CERN Document Server

    Kenning, Waylon

    2013-01-01

    This is a Packt Mini in a tutorial format that provides multiple examples on Identity Management using OpenAM 10.x.Open Source Identity Management Patterns and Practices Using OpenAM 10.x is great for developers and architects who are new to Identity Management, and who want a brief overview of what's possible and how to quickly implement a prototype. It's assumed that you've had experience with web applications and some knowledge of Apache and Tomcat.

  8. Radon-222 emissions and control practices for licensed uranium mills and their associated tailings piles. Final report

    International Nuclear Information System (INIS)

    1985-06-01

    The report is organized into five main sections. The conclusions of the effort are summarized in Chapter 2. A general description of current milling and tailings management practices and a summary of the site-specific characteristics of operating and standby uranium mills are contained in Chapter-3. The sources and emission rates of radon-222 at licensed mills and their associated tailings piles are contained in Chapter 4 along with the results of an effort to develop generic procedures to estimate radon-222 emissions for milling operations and tailings disposal. Control practices that are being or could be applied to the milling operation and tailings disposal areas and their estimated cost and effectiveness in reducing radon-222 emissions are presented in Chapter 5. The appendices contain detailed information on mill site data and emission estimates

  9. Regulatory control for safe usage of ionizing radiation sources in Bangladesh

    International Nuclear Information System (INIS)

    Mollah, A.S.

    2008-01-01

    Full text: In Bangladesh, there is a widespread and continuos growth in the use of the ionizing radiation sources both radioactive materials and radiation generating equipment in the field of industry, medicine, agriculture, research, teaching etc. In industry, they are employed in production as well as quality control such as non-destructive testing (radiography), nucleonic gauging, radiotracer techniques and in radiation processing. Medical applications of ionizing radiation include X-ray radiography, X-ray fluoroscopy, CT scan, mammography, nuclear medicine, beam therapy and brachytherapy. Besides radioisotopes are also used for research applications, viz., scattering experiments, tracer studies, etc. In agriculture, the uptake of nutrients by soil, and parts of plants are studied using suitable radionuclides. In all the above applications radioisotopes in two forms namely sealed sources and open sources in different chemical forms are employed with source strengths varying from micro curies to mega curies. The benefits to man from the use of ionizing radiation and sources of radiation are accompanied by risks which may result from exposure of man to ionizing radiation. In order to have an effective control on the use of radiation sources and to ensure radiological safety of the user as well as the public, Government of Bangladesh has promulgated Nuclear Safety and Radiation Control (NSRC) rules 1997 under the NSRC Act 1993. The Bangladesh Atomic Energy commission (BAEC) is the competent authority for formulating rules and regulations for ensuring radiological safety. BAEC is legally responsible for developing and strengthening the necessary radiation protection infrastructure in the country through the effective enforcement and implementation of regulatory requirements, criteria, obligations, guiding, codes etc. in order to save man and the related environment from the deleterious effects of ionizing radiation. In Bangladesh, only those persons who have been

  10. Research on wireless remote control scheme for the water source well of a uranium mine

    International Nuclear Information System (INIS)

    Wang Yun; Bao Feng

    2013-01-01

    Traditional wired electrical control method is applicable to simple control for the short-distance industrial equipment, but it is not suitable for the water source well of uranium mines requiring remote control. A kind of wireless remote control system based on high-speed radio modem communication technology was presented for the water source wells of a uranium mine, and the water source wells can be remotely controlled with the system. The component, implementation and characteristics of the control system are introduced. (authors)

  11. The Sources of Air Pollution and Their Control.

    Science.gov (United States)

    National Air Pollution Control Administration (DHEW), Arlington, VA.

    The problems of air pollution and its control are discussed. Major consideration is given the sources of pollution - motor vehicles, industry, power plants, space heating, and refuse disposal. Annual emission levels of five principle pollutants - carbon monoxide, sulfur dioxide, nitrogen oxides, hydrocarbons, and particulate matter - are listed…

  12. The geological controls of geothermal groundwater sources in Lebanon

    Energy Technology Data Exchange (ETDEWEB)

    Shaban, Amin [National Council for Scientific Research, Remote Sensing Center, Beirut (Lebanon); Khalaf-Keyrouz, Layla [Notre Dame University-Louaize, Zouk Mosbeh (Lebanon)

    2013-07-01

    Lebanon is a country that is relatively rich in water resources, as compared to its neighboring states in the Middle East. Several water sources are issuing on the surface or subsurface, including nonconventional water sources as the geothermal groundwater. This aspect of water sources exists in Lebanon in several localities, as springs or in deep boreholes. To the present little attention has been given to these resources and their geological setting is still unidentified. The preliminary geological field surveys revealed that they mainly occur in the vicinity of the basalt outcrops. Therefore, understanding their geological controls will help in exploring their origin, and thus giving insights into their economical exploitation. This can be investigated by applying advanced detection techniques, field surveys along with detailed geochemical analysis. This study aims at assessing the geographic distribution of the geothermal water in Lebanon with respect to the different geological settings and controls that govern their hydrogeologic regimes. It will introduce an approach for an integrated water resources management which became of utmost significance for the country.

  13. Airphoto analysis of erosion control practices

    Science.gov (United States)

    Morgan, K. M.; Morris-Jones, D. R.; Lee, G. B.; Kiefer, R. W.

    1980-01-01

    The Universal Soil Loss Equation (USLE) is a widely accepted tool for erosion prediction and conservation planning. In this study, airphoto analysis of color and color infrared 70 mm photography at a scale of 1:60,000 was used to determine the erosion control practice factor in the USLE. Information about contour tillage, contour strip cropping, and grass waterways was obtained from aerial photography for Pheasant Branch Creek watershed in Dane County, Wisconsin.

  14. Modeling in control of the Advanced Light Source

    International Nuclear Information System (INIS)

    Bengtsson, J.; Forest, E.; Nishimura, H.; Schachinger, L.

    1991-05-01

    A software system for control of accelerator physics parameters of the Advanced Light Source (ALS) is being designed and implemented at LBL. Some of the parameters we wish to control are tunes, chromaticities, and closed orbit distortions as well as linear lattice distortions and, possibly, amplitude- and momentum-dependent tune shifts. In all our applications, the goal is to allow the user to adjust physics parameters of the machine, instead of turning knobs that control magnets directly. This control will take place via a highly graphical user interface, with both a model appropriate to the application and any correction algorithm running alongside as separate processes. Many of these applications will run on a Unix workstation, separate from the controls system, but communicating with the hardware database via Remote Procedure Calls (RPCs)

  15. The control of radioactive sources in Brazil

    International Nuclear Information System (INIS)

    Oliveira, S.M.V.; Menezes, C.F.; Alves Filho, A.D.; Xavier, A.M.

    1998-01-01

    The radiological accident of Goiania in 1987 brought to light several deficiencies in the licensing of medical, industrial and research facilities, which handle radioisotopes, as well as in the control of radioactive sources in Brazil. The article describes some of the technical and administrative measures taken to ensure the adoption of appropriate radiological safety standards throughout the country and thereby reduce the incidence of radiological accidents. (author)

  16. Internal Corrosion Control of Water Supply Systems Code of Practice

    Science.gov (United States)

    This Code of Practice is part of a series of publications by the IWA Specialist Group on Metals and Related Substances in Drinking Water. It complements the following IWA Specialist Group publications: 1. Best Practice Guide on the Control of Lead in Drinking Water 2. Best Prac...

  17. Towards practical control design using neural computation

    Science.gov (United States)

    Troudet, Terry; Garg, Sanjay; Mattern, Duane; Merrill, Walter

    1991-01-01

    The objective is to develop neural network based control design techniques which address the issue of performance/control effort tradeoff. Additionally, the control design needs to address the important issue if achieving adequate performance in the presence of actuator nonlinearities such as position and rate limits. These issues are discussed using the example of aircraft flight control. Given a set of pilot input commands, a feedforward net is trained to control the vehicle within the constraints imposed by the actuators. This is achieved by minimizing an objective function which is the sum of the tracking errors, control input rates and control input deflections. A tradeoff between tracking performance and control smoothness is obtained by varying, adaptively, the weights of the objective function. The neurocontroller performance is evaluated in the presence of actuator dynamics using a simulation of the vehicle. Appropriate selection of the different weights in the objective function resulted in the good tracking of the pilot commands and smooth neurocontrol. An extension of the neurocontroller design approach is proposed to enhance its practicality.

  18. Status report on the ADVANCED LIGHT SOURCE control system

    International Nuclear Information System (INIS)

    Magyary, S.; Chin, M.; Fahmie, M.; Lancaster, H.; Molinari, P.; Robb, A.; Timossi, C.; Young, J.

    1992-01-01

    This paper is a status report on the ADVANCED LIGHT SOURCE (ALS) control system. The current status, performance data, and future plans will be discussed. Manpower, scheduling, and costs issues are addressed. (author)

  19. Examination of weight control practices in a non-clinical sample of college women.

    Science.gov (United States)

    Hayes, S; Napolitano, M A

    2012-09-01

    The current study examined healthy weight control practices among a sample of college women enrolled at an urban university (N=715; age=19.87±1.16; 77.2% Caucasian; 13.4% African American, 7.2% Asian, 2.2% other races). Participants completed measures as part of an on-line study about health habits, behaviors, and attitudes. Items from the Three Factor Eating Questionnaire were selected and evaluated with exploratory factor analysis to create a healthy weight control practices scale. Results revealed that college women, regardless of weight status, used a comparable number (four of eight) of practices. Examination of racial differences between Caucasian and African American women revealed that normal weight African American women used significantly fewer strategies than Caucasian women. Of note, greater use of healthy weight control practices was associated with higher cognitive restraint, drive for thinness, minutes of physical activity, and more frequent use of compensatory strategies. Higher scores on measures of binge and disinhibited eating, body dissatisfaction, negative affect, and depressive symptoms were associated with greater use of healthy weight control practices by underweight/normal weight but not by overweight/obese college women. Results suggest that among a sample of college females, a combination of healthy and potentially unhealthy weight control practices occurs. Implications of the findings suggest the need for effective weight management and eating disorder prevention programs for this critical developmental life stage. Such programs should be designed to help students learn how to appropriately use healthy weight control practices, as motivations for use may vary by weight status.

  20. 75 FR 22816 - Healthcare Infection Control Practices Advisory Committee (HICPAC)

    Science.gov (United States)

    2010-04-30

    ... Infectious Diseases (NCEZID), regarding the practice of hospital infection control and strategies for surveillance, prevention, and control of healthcare-associated infections (e.g., nosocomial infections... policy statements regarding prevention of healthcare- associated infections and healthcare-related...

  1. Applying neural networks to control the TFTR neutral beam ion sources

    International Nuclear Information System (INIS)

    Lagin, L.

    1992-01-01

    This paper describes the application of neural networks to the control of the neutral beam long-pulse positive ion source accelerators on the Tokamak Fusion Test Reactor (TFTR) at Princeton University. Neural networks were used to learn how the operators adjust the control setpoints when running these sources. The data sets used to train these networks were derived from a large database containing actual setpoints and power supply waveform calculations for the 1990 run period. The networks learned what the optimum control setpoints should initially be set based uon desired accel voltage and perveance levels. Neural networks were also used to predict the divergence of the ion beam

  2. Boosting up quantum key distribution by learning statistics of practical single-photon sources

    International Nuclear Information System (INIS)

    Adachi, Yoritoshi; Yamamoto, Takashi; Koashi, Masato; Imoto, Nobuyuki

    2009-01-01

    We propose a simple quantum-key-distribution (QKD) scheme for practical single-photon sources (SPSs), which works even with a moderate suppression of the second-order correlation g (2) of the source. The scheme utilizes a passive preparation of a decoy state by monitoring a fraction of the signal via an additional beam splitter and a detector at the sender's side to monitor photon-number splitting attacks. We show that the achievable distance increases with the precision with which the sub-Poissonian tendency is confirmed in higher photon-number distribution of the source, rather than with actual suppression of the multiphoton emission events. We present an example of the secure key generation rate in the case of a poor SPS with g (2) =0.19, in which no secure key is produced with the conventional QKD scheme, and show that learning the photon-number distribution up to several numbers is sufficient for achieving almost the same distance as that of an ideal SPS.

  3. The Human Face of Health News: A Multi-Method Analysis of Sourcing Practices in Health-Related News in Belgian Magazines.

    Science.gov (United States)

    De Dobbelaer, Rebeca; Van Leuven, Sarah; Raeymaeckers, Karin

    2018-05-01

    Health journalists are central gatekeepers who select, frame, and communicate health news to a broad audience, but the selection and content of health news are also influenced by the sources journalists, rely on (Hinnant, Len-Rios, & Oh, 2012). In this paper, we examine whether the traditional elitist sourcing practices (e.g., research institutions, government) are still important in a digitalized news environment where bottom-up non-elite actors (e.g., patients, civil society organizations) can act as producers (Bruns, 2003). Our main goal, therefore, is to detect whether sourcing practices in health journalism can be linked with strategies of empowerment. We use a multi-method approach combining quantitative and qualitative research methods. First, two content analyses are developed to examine health-related news in Belgian magazines (popular weeklies, health magazines, general interest magazines, and women's magazines). The analyses highlight sourcing practices as visible in the texts and give an overview of the different stakeholders represented as sources. In the first wave, the content analysis includes 1047 health-related news items in 19 different Belgian magazines (March-June 2013). In the second wave, a smaller sample of 202 health-related items in 10 magazines was studied for follow-up reasons (February 2015). Second, to contextualize the findings of the quantitative analysis, we interviewed 16 health journalists and editors-in-chief. The results illustrate that journalists consider patients and blogs as relevant sources for health news; nonetheless, elitist sourcing practices still prevail at the cost of bottom-up communication. However, the in-depth interviews demonstrate that journalists increasingly consult patients and civil society actors to give health issues a more "human" face. Importantly, the study reveals that this strategy is differently applied by the various types of magazines. While popular weeklies and women's magazines give a voice to

  4. 75 FR 50770 - Healthcare Infection Control Practices Advisory Committee (HICPAC)

    Science.gov (United States)

    2010-08-17

    ... Infectious Diseases (NCEZID), regarding: (1) The practice of hospital infection control; strategies for surveillance, prevention, and control of infections (e.g., nosocomial infections), antimicrobial resistance... and other policy statements regarding prevention of healthcare- associated infections and healthcare...

  5. Mobile source pollution control in the United States and China

    International Nuclear Information System (INIS)

    Menz, Fredric C

    2002-01-01

    This paper reviews policies for the control of mobile source pollution and their potential application in China. The first section of the paper reviews the U.S. experience with mobile source pollution control since regulations were first established in the Clean Air Act of 1970. Highlights in the policy and trends in vehicle emissions over the 1970 to 2000 time period are discussed. The second section of the paper discusses the range of policy instruments that could be used to control vehicle pollution, ranging from traditional direct regulations to market-based instruments. Experiences with the use of economic incentives in the United States and elsewhere are also discussed. The third section of the paper discusses possible implications of the U.S. experience for controlling vehicle pollution in China. While market-based instruments might be particularly appropriate for use in several aspects of China's pollution control policies, important differences between the institutional structures in China and the United States suggest that they should be phased in gradually. The paper closes with concluding remarks. (author)

  6. Mobile source pollution control in the United States and China

    Energy Technology Data Exchange (ETDEWEB)

    Menz, Fredric C

    2002-07-01

    This paper reviews policies for the control of mobile source pollution and their potential application in China. The first section of the paper reviews the U.S. experience with mobile source pollution control since regulations were first established in the Clean Air Act of 1970. Highlights in the policy and trends in vehicle emissions over the 1970 to 2000 time period are discussed. The second section of the paper discusses the range of policy instruments that could be used to control vehicle pollution, ranging from traditional direct regulations to market-based instruments. Experiences with the use of economic incentives in the United States and elsewhere are also discussed. The third section of the paper discusses possible implications of the U.S. experience for controlling vehicle pollution in China. While market-based instruments might be particularly appropriate for use in several aspects of China's pollution control policies, important differences between the institutional structures in China and the United States suggest that they should be phased in gradually. The paper closes with concluding remarks. (author)

  7. Control circuits in power electronics practical issues in design and implementation

    CERN Document Server

    Castilla, Miguel

    2016-01-01

    Control circuits are a key element in the operation and performance of power electronics converters. This book describes practical issues related to the design and implementation of these control circuits, and is divided into three parts - analogue control circuits, digital control circuits, and new trends in control circuits.

  8. Microbiological quality control practices at Australian Radioisotopes

    International Nuclear Information System (INIS)

    Saunders, M.

    1987-01-01

    As a domestic manufacturer of therapeutic substances, Australian Radioisotopes (ARI) must adhere to guidelines set out by the Commonwealth Department of Health in the Code of Good Manufacturing Practices for Therapeutic Goods 1983 (GMP). The GMP gives guidelines for staff training, building requirements, sanitation, documentation and quality control practices. These guidelines form the basis for regular audits performed by officers of the National Biological Standards Laboratories. At Lucas Heights, ARI has combined the principles of the GMP with the overriding precautions introduced for environmental and staff safety and protection. Its policy is to maintain a high level of quality assurance for product identity, purity and sterility and apyrogenicity during all stages of product manufacture

  9. Single-crate stand-alone CAMAC control system for a negative ion source test facility

    International Nuclear Information System (INIS)

    Juras, R.C.; Ziegler, N.F.

    1979-01-01

    A single-crate CAMAC system was configured to control a negative ion source development facility at ORNL and control software was written for the crate microcomputer. The software uses inputs from a touch panel and a shaft encoder to control the various operating parameters of the test facility and uses the touch panel to display the operating status. Communication to and from the equipment at ion source potential is accomplished over optical fibers from an ORNL-built CAMAC module. A receiver at ion source potential stores the transmitted data and some of these stored values are then used to control discrete parameters of the ion source (i.e., power supply on or off). Other stored values are sent to a multiplexed digital-to-analog converter to provide analog control signals. A transmitter at ion source potential transmits discrete status information and several channels of analog data from an analog-to-digital converter back to the ground-potential receiver where it is stored to be read and displayed by the software

  10. Recommended Practice for Patch Management of Control Systems

    Energy Technology Data Exchange (ETDEWEB)

    Steven Tom; Dale Christiansen; Dan Berrett

    2008-12-01

    A key component in protecting a nation’s critical infrastructure and key resources is the security of control systems. The term industrial control system refers to supervisory control and data acquisition, process control, distributed control, and any other systems that control, monitor, and manage the nation’s critical infrastructure. Critical Infrastructure and Key Resources (CIKR) consists of electric power generators, transmission systems, transportation systems, dam and water systems, communication systems, chemical and petroleum systems, and other critical systems that cannot tolerate sudden interruptions in service. Simply stated, a control system gathers information and then performs a function based on its established parameters and the information it receives. The patch management of industrial control systems software used in CIKR is inconsistent at best and nonexistent at worst. Patches are important to resolve security vulnerabilities and functional issues. This report recommends patch management practices for consideration and deployment by industrial control systems owners.

  11. 29 CFR 102.39 - Rules of evidence controlling so far as practicable.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 2 2010-07-01 2010-07-01 false Rules of evidence controlling so far as practicable. 102.39 Section 102.39 Labor Regulations Relating to Labor NATIONAL LABOR RELATIONS BOARD RULES AND REGULATIONS... Hearings § 102.39 Rules of evidence controlling so far as practicable. Any such proceeding shall, so far as...

  12. Observations of infection prevention and control practices in primary health care, Kenya.

    Science.gov (United States)

    Bedoya, Guadalupe; Dolinger, Amy; Rogo, Khama; Mwaura, Njeri; Wafula, Francis; Coarasa, Jorge; Goicoechea, Ana; Das, Jishnu

    2017-07-01

    To assess compliance with infection prevention and control practices in primary health care in Kenya. We used an observational, patient-tracking tool to assess compliance with infection prevention and control practices by 1680 health-care workers during outpatient interactions with 14 328 patients at 935 health-care facilities in 2015. Compliance was assessed in five domains: hand hygiene; protective glove use; injections and blood sampling; disinfection of reusable equipment; and waste segregation. We calculated compliance by dividing the number of correct actions performed by the number of indications and evaluated associations between compliance and the health-care worker's and facility's characteristics. Across 106 464 observed indications for an infection prevention and control practice, the mean compliance was 0.318 (95% confidence interval, CI: 0.315 to 0.321). The compliance ranged from 0.023 (95% CI: 0.021 to 0.024) for hand hygiene to 0.871 (95% CI: 0.866 to 0.876) for injection and blood sampling safety. Compliance was weakly associated with the facility's characteristics (e.g. public or private, or level of specialization) and the health-care worker's knowledge of, and training in, infection prevention and control practices. The observational tool was effective for assessing compliance with infection prevention and control practices across multiple domains in primary health care in a low-income country. Compliance varied widely across infection prevention and control domains. The weak associations observed between compliance and the characteristics of health-care workers and facilities, such as knowledge and the availability of supplies, suggest that a broader focus on behavioural change is required.

  13. A practical two-way system of quantum key distribution with untrusted source

    International Nuclear Information System (INIS)

    Chen Ming-Juan; Liu Xiang

    2011-01-01

    The most severe problem of a two-way 'plug-and-play' (p and p) quantum key distribution system is that the source can be controlled by the eavesdropper. This kind of source is defined as an “untrusted source . This paper discusses the effects of the fluctuation of internal transmittance on the final key generation rate and the transmission distance. The security of the standard BB84 protocol, one-decoy state protocol, and weak+vacuum decoy state protocol, with untrusted sources and the fluctuation of internal transmittance are studied. It is shown that the one-decoy state is sensitive to the statistical fluctuation but weak+vacuum decoy state is only slightly affected by the fluctuation. It is also shown that both the maximum secure transmission distance and final key generation rate are reduced when Alice's laboratory transmittance fluctuation is considered. (general)

  14. Controlling food, controlling relationships: exploring the meanings and dynamics of family food practices through the diary-interview approach.

    Science.gov (United States)

    MacDonald, Sarah; Murphy, Simon; Elliott, Eva

    2018-04-06

    Potential merits of a social practice perspective for examining the meanings and dynamics of family food include moving beyond individual behaviour, and exploring how practices emerge, develop and change. However, researchers have struggled to encourage reflection on mundane practices, and how to understand associated meanings. Drawing on a study of families in South Wales, this article reflects on the value of the diary-interview approach in addressing these methodological challenges, and aims to explore and understand the dynamics of control across family contexts. Contemporary practice theories distinguish between practices as 'performances' and practices as 'entities' and the diary-interview method facilitated an examination of these dimensions. Detailed accounts of daily 'performances' (through diaries), alongside reflection on underlying contexts and 'entities' (through interviews), illustrated the entanglement of control, practices and context. The article adds further complexity to the concept of practice 'bundles' which facilitated an understanding of how food was interrelated with other practices - across family contexts and across generations. Sociological approaches with a practices perspective at the core, offer potential for developing public health interventions by acknowledging: the relational meaning of food; the embeddedness of food within everyday practices; and the need to consider interventions across a range of policy areas. © 2018 Foundation for the Sociology of Health & Illness.

  15. A Practical Tuning Method for the Robust PID Controller with Velocity Feed-Back

    Directory of Open Access Journals (Sweden)

    Emre Sariyildiz

    2015-08-01

    Full Text Available Proportional-Integral-Derivative (PID control is the most widely used control method in industrial and academic applications due to its simplicity and efficiency. Several different control methods/algorithms have been proposed to tune the gains of PID controllers. However, the conventional tuning methods do not have sufficient performance and simplicity for practical applications, such as robotics and motion control. The performance of motion control systems may significantly deteriorate by the nonlinear plant uncertainties and unknown external disturbances, such as inertia variations, friction, external loads, etc., i.e., there may be a significant discrepancy between the simulation and experiment if the robustness is not considered in the design of PID controllers. This paper proposes a novel practical tuning method for the robust PID controller with velocity feed-back for motion control systems. The main advantages of the proposed method are the simplicity and efficiency in practical applications, i.e., a high performance robust motion control system can be easily designed by properly tuning conventional PID controllers. The validity of the proposal is verified by giving simulation and experimental results.

  16. Experimental Physics and Industrial Control System (EPICS): Application source/release control for EPICS R3.11.6

    International Nuclear Information System (INIS)

    Zieman, B.; Kraimer, M.

    1994-01-01

    This manual describes a set of tools that can be used to develop software for EPICS based control systems. It provides the following features: Multiple applications; the entire system is composed of an arbitrary number of applications: Source/Release Control; all files created or modified by the applications developers can be put under sccs (a UNIX Source/Release control utility): Multiple Developers; it allows a number of applications developers to work separately during the development phase but combine their applications for system testing and for a production system; Makefiles: makefiles are provided to automatically rebuild various application components. For C and state notation programs, Imagefiles are provided

  17. 78 FR 6329 - Healthcare Infection Control Practices Advisory Committee (HICPAC)

    Science.gov (United States)

    2013-01-30

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Healthcare... charged with providing advice and guidance to the Director, Division of Healthcare Quality Promotion, the... regarding: (1) The practice of healthcare infection prevention and control; (2) strategies for surveillance...

  18. Funding source and research report quality in nutrition practice-related research.

    Science.gov (United States)

    Myers, Esther F; Parrott, J Scott; Cummins, Deborah S; Splett, Patricia

    2011-01-01

    The source of funding is one of many possible causes of bias in scientific research. One method of detecting potential for bias is to evaluate the quality of research reports. Research exploring the relationship between funding source and nutrition-related research report quality is limited and in other disciplines the findings are mixed. The purpose of this study is to determine whether types of funding sources of nutrition research are associated with differences in research report quality. A retrospective study of research reporting quality, research design and funding source was conducted on 2539 peer reviewed research articles from the American Dietetic Association's Evidence Analysis Library® database. Quality rating frequency distributions indicate 43.3% of research reports were rated as positive, 50.1% neutral, and 6.6% as negative. Multinomial logistic regression results showed that while both funding source and type of research design are significant predictors of quality ratings (χ2 = 118.99, p≤0.001), the model's usefulness in predicting overall research report quality is little better than chance. Compared to research reports with government funding, those not acknowledging any funding sources, followed by studies with University/hospital funding were more likely to receive neutral vs positive quality ratings, OR = 1.85, P funding were more likely to receive negative quality ratings (OR = 4.97, Pfunded research reports were no more likely to receive a neutral or negative quality rating than those funded by government sources. Research report quality cannot be accurately predicted from the funding source after controlling for research design. Continued vigilance to evaluate the quality of all research regardless of the funding source and to further understand other factors that affect quality ratings are warranted.

  19. Knowledge, attitude and control practices of sickle cell disease ...

    African Journals Online (AJOL)

    Knowledge, attitude and control practices of sickle cell disease among youth corps members ... PROMOTING ACCESS TO AFRICAN RESEARCH ... access to haemopoeitic stem cell transplantation (HSCT) in our environment, stronger efforts ...

  20. Influence of fertilizer nitrogen source and management practice of N2O emissions from two black chernozemic soils

    International Nuclear Information System (INIS)

    Burton, D.L.

    2008-01-01

    Nitrous oxide (N 2 O) is a major anthropogenic greenhouse gas (GHG) emitted by Canadian agricultural systems. Emissions of N 2 O are sporadic, which complicates their accurate quantification as well as the development of adequate management practices. This study was conducted to determine the relative N 2 O production potentials of various nitrogen (N) fertilizer sources and application methods used in cereal production practices in Manitoba. Wheat crops were used to examine variations in N 2 O emissions associated with N formulations applied at the same rate. Treatments included urea surface broadcast in the spring; urea subsurface bands in spring; urea subsurface bands in the fall; anhydrous ammonia subsurface bands in spring and fall; and a control plot where no N was applied. Treatments of polymer-coated urea were also applied. The treatments were established in the fall of 1999. N 2 O fluxes were measured using vented static chambers. Samples were analyzed using gas chromatography. Analysis of variance (ANOVA) was performed in order to obtain cumulative annual N 2 O emissions. Results of the study showed that N 2 O emissions associated with the use of anhydrous ammonia were no greater than emissions associated with urea. Higher N 2 O emissions were observed in fall applications of N fertilizer. The dominant factors controlling differences in N 2 O emissions between sites and years included precipitation, soil water content, and soil texture. 26 refs., 6 tabs

  1. The IAEA Regional Training Course on Regulatory Control of Radiation Sources

    International Nuclear Information System (INIS)

    2000-01-01

    Materials of the IAEA Regional Training Course contains 8 presented lectures. Authors deals with regulatory control of radiation sources. The next materials of the IAEA were presented: Organization and implementation of a national regulatory infrastructure governing protection against ionizing radiation and the safety of radiation sources. (IAEA-TECDOC-1067); Safety assessment plants for authorization and inspection of radiation sources (IAEA-TECDOC-1113); Regulatory authority information system RAIS, Version 2.0, Instruction manual

  2. Modified source of a fast neutral atom beam with a controlled energy

    International Nuclear Information System (INIS)

    Gostev, V.A.; Elakhovskij, D.V.; Khakhaev, A.D.

    1980-01-01

    A source of a metastable helium atom beam with a controlled energy based on a phenomenon of resonant ion neutralization on the surface of a solid body is described. The neutral particle energy control is carried out by changing ion velocities before their transformation into metastable atoms. The results of experiments with a modified construction of atomic beam source are stated. These experiments were conducted to find the possibilities to control velocities of atoms in a flow as well as to elucidate the peculiarities of operation of a collimator-converter of this construction. Dependences of a halfwidth of the ion velocity distribution function on the ion source parameters have been investigated. The possibility for particle energy control in a collimated flow of fast neutral. atoms has been experimentally shown, it is also shown that a mean value of atom energy in a beam coincides with a value of mean energy of ions from which atoms are produced by the resonant neutralization method; the construction of the source provides the possibility to realize the method of ''overtaking beams'' for neutral atoms and as a result of this to give a possibility for studying atom-atom collisions in a wide energy range at relatively high densities of flows

  3. Variable cycle control model for intersection based on multi-source information

    Science.gov (United States)

    Sun, Zhi-Yuan; Li, Yue; Qu, Wen-Cong; Chen, Yan-Yan

    2018-05-01

    In order to improve the efficiency of traffic control system in the era of big data, a new variable cycle control model based on multi-source information is presented for intersection in this paper. Firstly, with consideration of multi-source information, a unified framework based on cyber-physical system is proposed. Secondly, taking into account the variable length of cell, hysteresis phenomenon of traffic flow and the characteristics of lane group, a Lane group-based Cell Transmission Model is established to describe the physical properties of traffic flow under different traffic signal control schemes. Thirdly, the variable cycle control problem is abstracted into a bi-level programming model. The upper level model is put forward for cycle length optimization considering traffic capacity and delay. The lower level model is a dynamic signal control decision model based on fairness analysis. Then, a Hybrid Intelligent Optimization Algorithm is raised to solve the proposed model. Finally, a case study shows the efficiency and applicability of the proposed model and algorithm.

  4. Nuclear power and other energy sources in the context of a smooth and practical social and economic development

    International Nuclear Information System (INIS)

    Sumitra, T.

    1996-01-01

    The dilemma on the adoption of nuclear energy for electricity generation has been going on for many years. On the one hand, nuclear energy is considered to be technically proven, relatively cheap and environmental friendly but concerns about the risk of a major accident and safe disposal of long-lived radioactive wastes are still controversial. On the other hand, the hope for cheap, clean and practical energy sources, such as renewable energy sources, is still alive and often cited as the real and only alternative to fossil fuels. This paper describes some arguments concerning all alternatives in the context of a smooth and practical social and economic development of a country. (author)

  5. REGIONAL DRAINWATER MANAGEMENT: SOURCE CONTROL, AGROFORESTRY, AND EVAPORATION PONDS

    OpenAIRE

    Posnikoff, Judith F.; Knapp, Keith C.

    1996-01-01

    Source control is one way to address salinity and drainage problems in irrigated agriculture, and reuse of drainage flows on salt-tolerant crops or trees in agroforestry production is another. A regional model of agricultural production with drainwater reuse and disposal is developed. Deep percolation flows are controlled through choice of crop areas, irrigation systems, and applied-water quantities. Crop drainwater may by reused in agroforestry production, and residual emissions are disposed...

  6. Control practices contribute to premature transformer failures

    Energy Technology Data Exchange (ETDEWEB)

    Jauch, E.T. [Beckwith Electric Company Inc., Largo, FL (United States)

    2007-07-01

    Studies of premature load tap changer (LTC) transformer failures on utility systems have shown the tap changers to be the primary contributing factor. Some of the LTC factors that lead to transformer failures include oil quality and particulate contamination; LTC contact temperature rise; contact coking; carbon film build-up; short circuit mechanical forces; and contact wear and arcing. These factors create increasing contact resistance thereby increasing voltage drop, localized heating, contact pitting, oil contamination and general deterioration. This paper discussed utility tapchanger control practices and methods of determining control functions to be activated as well as the determination of optimum settings contributing to excessive or untimely tap change operations. The transformer applications that were considered included transmission tie transformers as well as transmission distribution interface transformers. The paper discussed the circulating current paralleling method and the circulating reactive current or var sharing paralleling method. Several common practices were discussed, including basic voltage control ranges and setting effects; timing options available; LDC misapplications; first house protection methods; and various paralleling techniques. It was concluded that although there are several other methods of paralleling power transformers, many are not applicable under certain system configurations. In these applications, improper use of a paralleling method or improper setting and commissioning may cause hunting for appropriate tap positions and dramatically increase the number of tap changes, causing wear and degradation of the tap changer contacts. 3 refs., 5 figs.

  7. Status report on the Advanced Light Source control system, 1993

    International Nuclear Information System (INIS)

    Young, J.; Brown, W. Jr.; Cork, C.

    1993-10-01

    The Advanced Light Source (ALS), under construction for the past seven years, has become operational. The accelerator has been successfully commissioned using a control system based on hundreds of controllers of our own design and high performance personal computers which are the operator interface. The first beamlines are being commissioned using a control system based on VME hardware and the Experimental Physics and Industrial Control System (EPICS) software. The two systems are being integrated, and this paper reports on the current work being done

  8. Environmental radiation control and quality management system in design and operation of sealed radioactive sources

    International Nuclear Information System (INIS)

    Hussein, A.Z.

    2007-01-01

    New environmental regulations and radiation safety standards are being implemented almost daily to ensure radiation safety, in particular for practices causing exposures to undue radiation doses. A particular emphasis of real challenge for organizations and users of radiation sources has to be for proper radiological safety assessment and is becoming cost effectively to be prepared for auditing. Special concern for the environment is of global . nature, and hence environmental auditing has been and will continue to be an essential practice for improving the environment and for meeting the relevant regulations and standards. In general, most facilities that deal with radioactive sources undertake strict safety measures in terms of personnel radiation protection, handling procedures and security. Hence, those measures should comply with the requirements of the environmental protection standards. Accordingly, a successful quality management system must balance realities of organization and personnel in achieving quality objectives. Organizational principles are found in the technical aspects of' quality management, such as, charting, requirements, measurements, procedures, ... , etc. Human principles are found in the communication side of quality management (e.g. meetings, ,decision making, ,teams, ... , etc). The quality management must understand and balance skills needed to blend them together. Large gamma irradiators present a high potential radiation hazard to the surrounding environment, since the amount of radioactivity is of the order of (P Bq) and a very high dose rates are produced during irradiation. Application of environmental radiation control deemed by regulatory authority and a proper quality management system by the utility would serve public health and safety

  9. Optical networks a practical perspective

    CERN Document Server

    Ramaswami, Rajiv

    2001-01-01

    This fully updated and expanded second edition of Optical Networks: A Practical Perspective succeeds the first as the authoritative source for information on optical networking technologies and techniques. Written by two of the field's most respected individuals, it covers componentry and transmission in detail but also emphasizes the practical networking issues that affect organizations as they evaluate, deploy, or develop optical solutions. This book captures all the hard-to-find information on architecture, control and management, and other communications topics that

  10. Infection control practices across Canada: do dentists follow the recommendations?

    Science.gov (United States)

    McCarthy, G M; Koval, J J; John, M A; MacDonald, J K

    1999-10-01

    This study investigated provincial and territorial differences in dentists' compliance with recommended infection control practices in Canada (1995). Questionnaires were mailed to a stratified random sample of 6,444 dentists, of whom 66.4% responded. Weighted analyses included Pearson's chi-square test and multiple logistic regression. Significant provincial and territorial differences included testing for immune response after hepatitis B virus (HBV) vaccination, HBV vaccination for all clinical staff, use of infection control manuals and post-exposure protocols, biological monitoring of heat sterilizers, handwashing before treating patients, using gloves and changing them after each patient, heat-sterilizing handpieces between patients, and using masks and uniforms to protect against splatter of blood and saliva. Excellent compliance (compliance with a combination of 18 recommended infection control procedures) ranged from 0% to 10%; the best predictors were more hours of continuing education on infection control in the last two years, practice location in larger cities (> 500,000) and sex (female). Clearly, improvements in infection control are desirable for dentists in all provinces and territories. Extending mandatory continuing education initiatives to include infection control may promote better compliance with current recommendations.

  11. Sealed Radioactive Sources. Information, Resources, and Advice for Key Groups about Preventing the Loss of Control over Sealed Radioactive Sources

    International Nuclear Information System (INIS)

    2013-10-01

    Among its many activities to improve the safety and security of sealed sources, the IAEA has been investigating the root causes of major accidents and incidents since the 1980's and publishes findings so that others can learn from them. There are growing concerns today about the possibility that an improperly stored source could be stolen and used for malicious purposes. To improve both safety and security, information needs to be in the hands of those whose actions and decisions can prevent a source from being lost or stolen in the first place. The IAEA developed this booklet to help improve communication with key groups about hazards that may result from the loss of control over sealed radioactive sources and measures that should be implemented to prevent such loss of control. Many people may benefit from the information contained in this booklet, particularly those working with sources and those likely to be involved if control over a source is lost; especially: officials in government agencies, first responders, medical users, industrial users and the metal recycling industry. The general public may also benefit from an understanding of the fundamentals of radiation safety. This booklet is comprised of several stand-alone chapters intended to communicate with these key groups. Various accidents that are described and information that is provided are relevant to more than one key group and therefore, some information is repeated throughout the booklet. This booklet seeks to raise awareness of the importance of the safety and security of sealed radioactive sources. However, it is not intended to be a comprehensive 'how to' guide for implementing safety and security measures for sealed radioactive sources. For more information on these measures, readers are encouraged to consult the key IAEA safety and security-related publications identified in this booklet

  12. The regulatory control of radiation sources in Australia -- The challenges of a federal system

    International Nuclear Information System (INIS)

    Loy, J.; Colgan, P.

    2001-01-01

    The report refers to the challenges that Australia is facing, as a federal nation having a Commonwealth Government and six States and two territories, in establishing appropriate regulatory control of radiation sources. Information on the national inventory of radiation sources and existing regulatory infrastructure, including the system of notification, registration, licensing, inspection and enforcement, is explained in the report. The national provisions for the management of disused sources; the planning, preparedness and response to abnormal events and emergencies; the recovery of control over orphan sources; and education and training; are specifically emphasized. (author)

  13. Infection prevention and control practices in children's hospitals.

    Science.gov (United States)

    Bender, Jeffrey M; Virgallito, Mary; Newland, Jason G; Sammons, Julia S; Thorell, Emily A; Coffin, Susan E; Pavia, Andrew T; Sandora, Thomas J; Hersh, Adam L

    2015-05-01

    We surveyed hospital epidemiologists at 28 Children's Hospital Association member hospitals regarding their infection prevention and control programs. We found substantial variability between children's hospitals in both the structure and the practice of these programs. Research and the development of evidence-based guidelines addressing infection prevention in pediatrics are needed.

  14. Vector control of three-phase AC machines system development in the practice

    CERN Document Server

    Quang, Nguyen Phung; Dittrich, J

    2015-01-01

    This book addresses the vector control of three-phase AC machines, in particular induction motors with squirrel-cage rotors (IM), permanent magnet synchronous motors (PMSM) and doubly-fed induction machines (DFIM), from a practical design and development perspective. The main focus is on the application of IM and PMSM in electrical drive systems, where field-orientated control has been successfully established in practice. It also discusses the use of grid-voltage oriented control of DFIMs in wind power plants. This second, enlarged edition includes new insights into flatness-based  nonlinear

  15. Robust power system frequency control

    CERN Document Server

    Bevrani, Hassan

    2014-01-01

    This updated edition of the industry standard reference on power system frequency control provides practical, systematic and flexible algorithms for regulating load frequency, offering new solutions to the technical challenges introduced by the escalating role of distributed generation and renewable energy sources in smart electric grids. The author emphasizes the physical constraints and practical engineering issues related to frequency in a deregulated environment, while fostering a conceptual understanding of frequency regulation and robust control techniques. The resulting control strategi

  16. National Management Measures to Control Nonpoint Source Pollution from Forestry

    Science.gov (United States)

    This report helps forest owners protect lakes and streams from polluted runoff that can result from forestry activities. The report will also help states to implement their nonpoint source control programs.

  17. What are the Main Sources of Turkish EFL Students’ Anxiety in Oral Practice?

    Directory of Open Access Journals (Sweden)

    Gonca Subaşı

    2010-10-01

    Full Text Available This study was designed in order to investigate two potential sources of the anxiety of Turkish learners of English in oral practice:1 an individual student’s fear of negative evaluation, and 2 his/her self-perceived speaking ability. A total of 55 first year students enrolling in Anadolu University, Education Faculty, ELT Department participated in the study. A 55-item multiple-choice survey was administered to the participants in a regular classroom hour. The survey consisted of five parts: Fear of Negative Evaluation (FNE, Foreign Language Classroom Anxiety Scale (FLCAS, Self-Rating Can-Do Scale (SR-CDS, Self-Rating for the Current Level of Study (SR-CL, Self-Rating Perception by the English (SR-EPE. The Pearson correlation coefficients and multiple regression analyses were run for the statistical interpretation of the data. To achieve valid and reliable results, 15 students were also randomly chosen to conduct an interview in order to find out their reasons for being anxious in using English. The students’ responses given to the survey were probed to have a better understanding of sources leading to high anxiety. The results of the study indicated a positive correlation between an individual’s fear of negative evaluation and his/her anxiety level. Moreover, the findings of the current study revealed that there were significant negative relationships between anxiety and three of self-ratings; SR-CDS, SR-CL and SR-EPE. In addition, it was showed that among the FNE and the three self-ratings of English speaking ability, the combination of the FNE, the SR-CL and SR-CDS was the most appropriate model of predictors of anxiety level of this sample. Finally, the analysis of interview data provided valuable information about the main sources of the students’ anxiety in oral practice such as: personal reasons, teachers’ manners, teaching procedures, and previous experience.

  18. Fully Automated Driving: Impact of Trust and Practice on Manual Control Recovery.

    Science.gov (United States)

    Payre, William; Cestac, Julien; Delhomme, Patricia

    2016-03-01

    An experiment was performed in a driving simulator to investigate the impacts of practice, trust, and interaction on manual control recovery (MCR) when employing fully automated driving (FAD). To increase the use of partially or highly automated driving efficiency and to improve safety, some studies have addressed trust in driving automation and training, but few studies have focused on FAD. FAD is an autonomous system that has full control of a vehicle without any need for intervention by the driver. A total of 69 drivers with a valid license practiced with FAD. They were distributed evenly across two conditions: simple practice and elaborate practice. When examining emergency MCR, a correlation was found between trust and reaction time in the simple practice group (i.e., higher trust meant a longer reaction time), but not in the elaborate practice group. This result indicated that to mitigate the negative impact of overtrust on reaction time, more appropriate practice may be needed. Drivers should be trained in how the automated device works so as to improve MCR performance in case of an emergency. The practice format used in this study could be used for the first interaction with an FAD car when acquiring such a vehicle. © 2015, Human Factors and Ergonomics Society.

  19. Regularity of the wear control of radioactive sources from the nuclear measurers

    International Nuclear Information System (INIS)

    Ferreira L, M.

    2006-01-01

    The control of radioactive sources in Brazil is regulated by the CNEN (National Comissao of Nuclear Energy). The Laboratory of Descontaminacao of the IPEN (Institute of Energy Y Nuclear Investigations) it offers to the companies that work with nuclear measurers, essays for control of the source wear according to the ISO 9978/1992 through the smear tests Y of leakage. The analyses are taken in alpha Y beta detectors of low bottom radiation with annual detection limits around 1 Bq. Certificates of the accepted analyses by the CNEN for sources that already passed its time of validity assured by the makers, but its continue operational are emitted. The smear test is repeated the whole year, while the leakage test repeats to every two years. A balance of the last two years of the activities of the laboratory shows the regularity of the clients Y the growth of companies specialized in radioprotection with official of radioprotection, credited by the regulatory authority that its act as intermediaries in the process, contacting the clients, gathering the samples next to the proprietors of sources Y hiring our services. Overalls, proves that the inspection activities by part of the regulatory authority are fulfil. In 2004, 192 sources were analyzed by the smear method Y 86 sources by leakage. In 2005, 232 sources were analyzed by the smear method Y 60 sources by leakage. All the leakage tests was made in sources of Americium of oneself Y only client that brings the sources so that they dismantle them to him in the Sources production laboratory of the IPEN. By the quantity Y age of the sources that were analyzed in those two years, it is proven that the number of sources without use conditions (total activity measured by the two added methods smaller than 180Bq) it doesn't arrive to 2%. (Author)

  20. Power Controllability of Three-phase Converter with Unbalanced AC Source

    DEFF Research Database (Denmark)

    Ma, Ke; Chen, Wenjie; Liserre, Marco

    2015-01-01

    Three-phase DC-AC power converters suffer from power oscillation and overcurrent problems in case of unbalanced AC source voltage that can be caused by grid/generator faults. Existing solutions to handle these problems are properly selecting and controlling the positive and negative sequence...... currents. In this work a new series of control strategies which utilize the zerosequence components are proposed to enhance the power control ability under this adverse condition. It is concluded that by introducing proper zero sequence current controls and corresponding circuit configurations, the power...... converter can enable more flexible control targets, achieving better performances in the delivered power and load current when suffering from unbalanced AC voltage....

  1. Identification of Cu’s sources in Jiaozhou Bay

    Science.gov (United States)

    Yang, Dongfang; Li, Haixia; Ding, Jun; Zhang, Longlei; Li, Jiangmin

    2017-12-01

    Many marine bays have been polluted by Cu along with the rapid development of industry, economy and population size, and identification the sources of Cu is essential to environmental protection. This paper identified the sources of Cu in according to the horizontal distribution in Jiaozhou Bay during 1982-1986. Results showed that there were five Cu sources during study years including marine current, stream flow, island top, overland runoff and marine traffic, respectively. These findings were helpful information in decision-making of pollution control and environmental remediation practice.

  2. Fissile material detection and control facility with pulsed neutron sources and digital data processing

    International Nuclear Information System (INIS)

    Romodanov, V.L.; Chernikova, D.N.; Afanasiev, V.V.

    2010-01-01

    Full text: In connection with possible nuclear terrorism, there is long-felt need of devices for effective control of radioactive and fissile materials in the key points of crossing the state borders (airports, seaports, etc.), as well as various customs check-points. In International Science and Technology Center Projects No. 596 and No. 2978, a new physical method and digital technology have been developed for the detection of fissile and radioactive materials in models of customs facilities with a graphite moderator, pulsed neutron source and digital processing of responses from scintillation PSD detectors. Detectability of fissile materials, even those shielded with various radiation-absorbing screens, has been shown. The use of digital processing of scintillation signals in this facility is a necessary element, as neutrons and photons are discriminated in the time dependence of fissile materials responses at such loads on the electronic channels that standard types of spectrometers are inapplicable. Digital processing of neutron and photon responses practically resolves the problem of dead time and allows implementing devices, in which various energy groups of neutrons exist for some time after a pulse of source neutrons. Thus, it is possible to detect fissile materials deliberately concealed with shields having a large cross-section of absorption of photons and thermal neutrons. Two models of detection and the control of fissile materials were advanced: 1. the model based on graphite neutrons moderator and PSD scintillators with digital technology of neutrons and photons responses separation; 2. the model based on plastic scintillators and detecting of time coincidences of fission particles by digital technology. Facilities that count time coincidences of neutrons and photons occurring in the fission of fissile materials can use an Am Li source of neutrons, e.g. that is the case with the AWCC system. The disadvantages of the facility are related to the issues

  3. Business annual planning and controlling in Slovenian managerial practice

    OpenAIRE

    Pučko, Danijel; Čater, Tomasž

    2001-01-01

    Management process is usually segmented into planning, organizing, leading and controlling. The first and the last of these subprocesses are analyzed in the paper from the economic and managerial viewpoint as they occurr in Slovenian enterprise practice. The focus is on empirical research on a tactical level. Business analysis, tactical planning and controlling are the core issues analyzed in the article. The paper builds heavily on presenting empirical findings regarding the empirical system...

  4. Amortization as source of capital investments in Belarus: historiography, theoretical and practical aspects

    Directory of Open Access Journals (Sweden)

    S.L. Korotayev

    2016-12-01

    Full Text Available The article focuses on the historiography of defining amortization as the source of further reproduction and creation due to the amortization of sinking funds, used by economic entities for future capital investments. Acting as the source of capital investments, sinking funds were established during the socialist era, as well as in the post-Soviet period, that is before the beginning of the 21st century. However, starting from 2010, economic entities no longer have been creating sinking funds on the balance sheet and outside it, that corresponds to the international practice, in particular the rules and principles of International Financial Reporting Standards. The author proves that the amortization, recoverable in the price of goods (works, services, is the reimbursement of the past, not future expenditures. Accordingly, the sinking funds, as the source of future investments, cannot be made at the expenses of amortization charges. At the same time, the author analyzes the possible consequences of the legal right of enterprises to unchanged amortization installments in the reporting period with the extension of the life of depreciable fixed assets for the period when no amortization charges were calculated.

  5. Note: Tormenta: An open source Python-powered control software for camera based optical microscopy.

    Science.gov (United States)

    Barabas, Federico M; Masullo, Luciano A; Stefani, Fernando D

    2016-12-01

    Until recently, PC control and synchronization of scientific instruments was only possible through closed-source expensive frameworks like National Instruments' LabVIEW. Nowadays, efficient cost-free alternatives are available in the context of a continuously growing community of open-source software developers. Here, we report on Tormenta, a modular open-source software for the control of camera-based optical microscopes. Tormenta is built on Python, works on multiple operating systems, and includes some key features for fluorescence nanoscopy based on single molecule localization.

  6. Effectiveness in practice-based research: Looking for alternatives to the randomized controlled trial (RCT)

    NARCIS (Netherlands)

    Tavecchio, L.

    2015-01-01

    Over the last decade, the status of the randomized controlled trial (RCT), hallmark of evidence-based medicine (research), has been growing strongly in general practice, social work and public health. But this type of research is only practicable under strictly controlled and well-defined settings

  7. The Potential Of Cultural And Chemical Control Practices For ...

    African Journals Online (AJOL)

    The Potential Of Cultural And Chemical Control Practices For Enhancing ... and a significant (P < 0.05) increase in yield components of hands per bunch and finger ... Une étude de l\\'effet de la population de plantes, l\\'application des engrais, ...

  8. The National Implementation of Nuclear Export Controls: Developing a Best Practices Model

    Energy Technology Data Exchange (ETDEWEB)

    Viski, Andrea [European University Institute, Department of Law, Badia Fiesolana, S.Domenico di Fiesole, Firenze (Italy)

    2011-12-15

    The nuclear renaissance promises significant benefits to the international community, but also raises security challenges, particularly relating to the trade of nuclear materials and equipment. The objective of this paper is to examine how supply-side non-proliferation efforts can be strengthened by developing a best practices model for national nuclear export control implementation. In order to achieve this goal, nuclear export control measures identified by the 1540 Committee will be used as a framework from which a best practices model can be formed. Such a model concentrates specifically on national legislation and enforcement measures delineated by the Committee in order to bring countries in accordance with international law. Developing a best practices model seeks to deliver an ideal process for national export control law actualization in order to encourage the peaceful development of nuclear energy and develop the infrastructure and framework for precluding nuclear proliferation.

  9. Regulatory control of radiation sources and radioactive materials in the Czech Republic

    International Nuclear Information System (INIS)

    Drabova, D.; Prouza, Z.

    2001-01-01

    The paper describes legal and regulatory provisions for radiation protection and safe use of sources of ionizing radiation in the Czech Republic with special emphasis on aspects of bringing activities under regulatory control and releasing them from it. It covers the development of a new legal framework, the work of the regulatory body, an overview of sources in use and provisions to achieve effective regulatory control of facilities and releases of radioactive material into the environment. Also, it describes reported unusual events with a proposed scheme for their classification and evaluation. (author)

  10. Clinical evaluation of semi-automatic open-source algorithmic software segmentation of the mandibular bone: Practical feasibility and assessment of a new course of action.

    Science.gov (United States)

    Wallner, Jürgen; Hochegger, Kerstin; Chen, Xiaojun; Mischak, Irene; Reinbacher, Knut; Pau, Mauro; Zrnc, Tomislav; Schwenzer-Zimmerer, Katja; Zemann, Wolfgang; Schmalstieg, Dieter; Egger, Jan

    2018-01-01

    Computer assisted technologies based on algorithmic software segmentation are an increasing topic of interest in complex surgical cases. However-due to functional instability, time consuming software processes, personnel resources or licensed-based financial costs many segmentation processes are often outsourced from clinical centers to third parties and the industry. Therefore, the aim of this trial was to assess the practical feasibility of an easy available, functional stable and licensed-free segmentation approach to be used in the clinical practice. In this retrospective, randomized, controlled trail the accuracy and accordance of the open-source based segmentation algorithm GrowCut was assessed through the comparison to the manually generated ground truth of the same anatomy using 10 CT lower jaw data-sets from the clinical routine. Assessment parameters were the segmentation time, the volume, the voxel number, the Dice Score and the Hausdorff distance. Overall semi-automatic GrowCut segmentation times were about one minute. Mean Dice Score values of over 85% and Hausdorff Distances below 33.5 voxel could be achieved between the algorithmic GrowCut-based segmentations and the manual generated ground truth schemes. Statistical differences between the assessment parameters were not significant (p 0.94) for any of the comparison made between the two groups. Complete functional stable and time saving segmentations with high accuracy and high positive correlation could be performed by the presented interactive open-source based approach. In the cranio-maxillofacial complex the used method could represent an algorithmic alternative for image-based segmentation in the clinical practice for e.g. surgical treatment planning or visualization of postoperative results and offers several advantages. Due to an open-source basis the used method could be further developed by other groups or specialists. Systematic comparisons to other segmentation approaches or with a

  11. Informal interpreting in general practice: Are interpreters' roles related to perceived control, trust, and satisfaction?

    Science.gov (United States)

    Zendedel, Rena; Schouten, Barbara C; van Weert, Julia C M; van den Putte, Bas

    2018-06-01

    The aim of this observational study was twofold. First, we examined how often and which roles informal interpreters performed during consultations between Turkish-Dutch migrant patients and general practitioners (GPs). Second, relations between these roles and patients' and GPs' perceived control, trust in informal interpreters and satisfaction with the consultation were assessed. A coding instrument was developed to quantitatively code informal interpreters' roles from transcripts of 84 audio-recorded interpreter-mediated consultations in general practice. Patients' and GPs' perceived control, trust and satisfaction were assessed in a post consultation questionnaire. Informal interpreters most often performed the conduit role (almost 25% of all coded utterances), and also frequently acted as replacers and excluders of patients and GPs by asking and answering questions on their own behalf, and by ignoring and omitting patients' and GPs' utterances. The role of information source was negatively related to patients' trust and the role of GP excluder was negatively related to patients' perceived control. Patients and GPs are possibly insufficiently aware of the performed roles of informal interpreters, as these were barely related to patients' and GPs' perceived trust, control and satisfaction. Patients and GPs should be educated about the possible negative consequences of informal interpreting. Copyright © 2018 Elsevier B.V. All rights reserved.

  12. Practical synchronization on complex dynamical networks via optimal pinning control

    Science.gov (United States)

    Li, Kezan; Sun, Weigang; Small, Michael; Fu, Xinchu

    2015-07-01

    We consider practical synchronization on complex dynamical networks under linear feedback control designed by optimal control theory. The control goal is to minimize global synchronization error and control strength over a given finite time interval, and synchronization error at terminal time. By utilizing the Pontryagin's minimum principle, and based on a general complex dynamical network, we obtain an optimal system to achieve the control goal. The result is verified by performing some numerical simulations on Star networks, Watts-Strogatz networks, and Barabási-Albert networks. Moreover, by combining optimal control and traditional pinning control, we propose an optimal pinning control strategy which depends on the network's topological structure. Obtained results show that optimal pinning control is very effective for synchronization control in real applications.

  13. Variable speed wind turbine generator system with current controlled voltage source inverter

    International Nuclear Information System (INIS)

    Muyeen, S.M.; Al-Durra, Ahmed; Tamura, J.

    2011-01-01

    highlights: → Current controlled voltage source inverter scheme for wind power application. → Low voltage ride through of wind farm. → Variable speed wind turbine driven permanent magnet synchronous generator-operation and control. -- Abstract: The present popular trend of wind power generation is to use variable speed wind turbine (VSWT) driving a doubly fed induction generator (DFIG), wound field synchronous generator (WFSG) or permanent magnet synchronous generator (PMSG). Among them, stability analyses of DFIG type of VSWT have already been reported in many literatures. However, transient stability and low voltage ride through (LVRT) characteristics analyses for synchronous generator type of VSWT is not sufficient enough. This paper focuses on detailed LVRT characteristic analysis of variable speed wind turbine driving a PMSG (VSWT-PMSG) with current controlled voltage source inverter (CC-VSI). Modeling and suitable control strategies for overall system are developed to augment the low voltage ride through capability of variable speed wind generator, considering recent wind farm grid code. Both symmetrical and unsymmetrical faults are analyzed as network disturbances in this paper. The permanent fault due to unsuccessful reclosing of circuit breakers is taken into consideration, which is a salient feature of this study. Moreover, the dynamic characteristic is analyzed using real wind speed data measured in Hokkaido Island, Japan. The proposed control scheme is simulated by using the standard power system simulation package PSCAD/EMTDC and results are verified by comparing that of voltage controlled voltage source inverter scheme available in power system literature.

  14. Variable speed wind turbine generator system with current controlled voltage source inverter

    Energy Technology Data Exchange (ETDEWEB)

    Muyeen, S.M., E-mail: muyeen0809@yahoo.co [Dept. of Electrical Engineering, Petroleum Institute, P.O. Box 2533, Abu Dhabi (United Arab Emirates); Al-Durra, Ahmed [Dept. of Electrical Engineering, The Petroleum Institute, P.O. Box 2533, Abu Dhabi (United Arab Emirates); Tamura, J. [Dept. of EEE, Kitami Institute of Technology, 165 Koen-cho, Kitami 090-8507 (Japan)

    2011-07-15

    highlights: {yields} Current controlled voltage source inverter scheme for wind power application. {yields} Low voltage ride through of wind farm. {yields} Variable speed wind turbine driven permanent magnet synchronous generator-operation and control. -- Abstract: The present popular trend of wind power generation is to use variable speed wind turbine (VSWT) driving a doubly fed induction generator (DFIG), wound field synchronous generator (WFSG) or permanent magnet synchronous generator (PMSG). Among them, stability analyses of DFIG type of VSWT have already been reported in many literatures. However, transient stability and low voltage ride through (LVRT) characteristics analyses for synchronous generator type of VSWT is not sufficient enough. This paper focuses on detailed LVRT characteristic analysis of variable speed wind turbine driving a PMSG (VSWT-PMSG) with current controlled voltage source inverter (CC-VSI). Modeling and suitable control strategies for overall system are developed to augment the low voltage ride through capability of variable speed wind generator, considering recent wind farm grid code. Both symmetrical and unsymmetrical faults are analyzed as network disturbances in this paper. The permanent fault due to unsuccessful reclosing of circuit breakers is taken into consideration, which is a salient feature of this study. Moreover, the dynamic characteristic is analyzed using real wind speed data measured in Hokkaido Island, Japan. The proposed control scheme is simulated by using the standard power system simulation package PSCAD/EMTDC and results are verified by comparing that of voltage controlled voltage source inverter scheme available in power system literature.

  15. Automatic control system for the pig ion source for the U-400 cyclotron

    International Nuclear Information System (INIS)

    Kutner, V.B.; Subbotin, V.G.; Sukhov, A.M.; Tret'yakov, Yu.P.; Fefilov, B.V.

    1989-01-01

    An automatic control system is described for the cyclotron U-400 multiply-charged ion source based on CAMAC apparatus and microprocesor controllers. The system allows the automatic tuning of the ion source to the necessary regime including the automatic start-up of discharge, the obtaining of the necessary parameters of sputtering, the automatic search for a maximum beam current within the given discharge parameters. The system performs tuning the ion source to the quasioptimal regime for 10-15 minutes with up to 5% deviation from the preset parameters. It is possible to stabilize the beam current within 3% using the automatic correction of the discharge regime. 6 refs.; 4 figs

  16. Automatic control system of the PIG ion source for the U-400 cyclotron

    International Nuclear Information System (INIS)

    Kutner, V.B.; Subbotin, V.G.; Sukhov, A.M.; Tretyakov, Y.P.; Fefilov, B.V.; Kasyanov, A.A.; Rybin, V.M.

    1990-01-01

    An automatic control system is described for the multiply charged ion source of the U-400 cyclotron based on CAMAC apparatus and microprocessor controllers. The system allows the automatic tuning of the ion source to the necessary regime, including the automatic start-up of discharge, determination of the necessary parameters of sputtering, and the automatic search for a maximum beam current for given discharge parameters. The system performs the tuning of the ion source to the quasioptimal regime in 10--15 min with up to 5% deviation from the preset parameters. It is possible to stabilize the beam current within 3% using the automatic correction of the discharge regime

  17. Weed control through crop rotation and alternative management practices

    Directory of Open Access Journals (Sweden)

    Böhm, Herwart

    2014-02-01

    Full Text Available Economic as well as agricultural and socio-political changes have an impact on crop management and thus also on crop rotation design and the related effects on the weed flora. Likewise other changes in cultivation such as reduced tillage practices, earlier sowing date, etc. cause an increase in weed infestation resp. an increased use of herbicides and if so contribute to herbicide resistance. The positive effects of crop rotation, but also of alternative management practices such as choice of varieties, catch crops, mixed cropping, green chop, and the share of predators, as well as methods of direct non-chemical weed control are presented and discussed for both, conventional and organic farming. If alternative management methods should be more practiced, especially trade-offs need to be broken, or incentives be offered.

  18. Impact of implementing electronic clinical practice guidelines for the diagnosis, control and treatment of cardiovascular risk factors: A pre-post controlled study.

    Science.gov (United States)

    Comin, Eva; Catalan-Ramos, Arantxa; Iglesias-Rodal, Manuel; Grau, Maria; Del Val, Jose Luis; Consola, Alicia; Amado, Ester; Pons, Angels; Mata-Cases, Manel; Franzi, Alicia; Ciurana, Ramon; Frigola, Eva; Cos, Xavier; Davins, Josep; Verdu-Rotellar, Jose M

    To evaluate the impact of computerized clinical practice guidelines on the management, diagnosis, treatment, control, and follow-up of the main cardiovascular risk factors: hypertension, hypercholesterolaemia, and type 2 diabetes mellitus. Pre-post controlled study. Catalonia, autonomous community located in north-eastern Spain. Individuals aged 35-74 years assigned to general practitioners of the Catalan Health Institute. The intervention group consisted of individuals whose general practitioners had accessed the computerized clinical practice guidelines at least twice a day, while the control group consisted of individuals whose general practitioner had never accessed the computerized clinical practice guidelines platform. The Chi-squared test was used to detect significant differences in the follow-up, control, and treatment variables for all three disorders (hypertension, hypercholesterolaemia, and type 2 diabetes mellitus) between individuals assigned to users and non-users of the computerized clinical practice guidelines, respectively. A total of 189,067 patients were included in this study, with a mean age of 56 years (standard deviation 12), and 55.5% of whom were women. Significant differences were observed in hypertension management, treatment and control; type 2 diabetes mellitus management, treatment and diagnoses, and the management and control of hypercholesterolaemia in both sexes. Computerized clinical practice guidelines are an effective tool for the control and follow-up of patients diagnosed with hypertension, type 2 diabetes mellitus, and hypercholesterolaemia. The usefulness of computerized clinical practice guidelines to diagnose and adequately treat individuals with these disorders remains unclear. Copyright © 2016 Elsevier España, S.L.U. All rights reserved.

  19. Video game practice optimizes executive control skills in dual-task and task switching situations.

    Science.gov (United States)

    Strobach, Tilo; Frensch, Peter A; Schubert, Torsten

    2012-05-01

    We examined the relation of action video game practice and the optimization of executive control skills that are needed to coordinate two different tasks. As action video games are similar to real life situations and complex in nature, and include numerous concurrent actions, they may generate an ideal environment for practicing these skills (Green & Bavelier, 2008). For two types of experimental paradigms, dual-task and task switching respectively; we obtained performance advantages for experienced video gamers compared to non-gamers in situations in which two different tasks were processed simultaneously or sequentially. This advantage was absent in single-task situations. These findings indicate optimized executive control skills in video gamers. Similar findings in non-gamers after 15 h of action video game practice when compared to non-gamers with practice on a puzzle game clarified the causal relation between video game practice and the optimization of executive control skills. Copyright © 2012 Elsevier B.V. All rights reserved.

  20. National Strategy for Regaining Control Over Orphan Sources and Improving Control Over Vulnerable Sources

    International Nuclear Information System (INIS)

    2011-01-01

    . The standards are also applied by regulatory bodies and operators around the world to enhance safety in nuclear power generation and in nuclear applications in medicine, industry, agriculture and research. Safety is not an end in itself but a prerequisite for the purpose of the protection of people in all States and of the environment - now and in the future. The risks associated with ionizing radiation must be assessed and controlled without unduly limiting the contribution of nuclear energy to equitable and sustainable development. Governments, regulatory bodies and operators everywhere must ensure that nuclear material and radiation sources are used beneficially, safely and ethically. The IAEA safety standards are designed to facilitate this, and I encourage all Member States to make use of them.

  1. Silica dust control in small-scale building/structure demolition operations using good work practice guidance

    International Nuclear Information System (INIS)

    Muianga, C V; Rice, C H; Succop, P

    2009-01-01

    Work practices can influence exposure, especially in small-scale operations conducted by mobile work crews. This study evaluated the use of information on good work practice in control guidance sheets adapted from UK Silica Essentials guidance sheets by trained workers and supervisors employed in small-scale concrete and masonry demolition operations. A one-page employee silica task-based control guidance sheet for each of four demolition tasks and multiple-page silica control guidance for supervisors were developed. Interactive, hands-on worker training on these task-based good work practice controls was developed. Training was presented to 26 participants from two demolition crews. Feedback on the training and task-based good work practice control guidance sheets was elicited. Observations of work practices were made before and after training. Participants indicated gains in knowledge and checklists were used to document skill attainment. The quality of the training and usefulness of the material/skills was rated high by trainees. Increased use of water to suppress dust and wet cleaning methods on the job were documented following the training. Additional follow-up after training is required to determine long-term impact on sustained changes in work practices, and to evaluate the need for refresher training.

  2. Silica dust control in small-scale building/structure demolition operations using good work practice guidance

    Science.gov (United States)

    Muianga, C. V.; Rice, C. H.; Succop, P.

    2009-02-01

    Work practices can influence exposure, especially in small-scale operations conducted by mobile work crews. This study evaluated the use of information on good work practice in control guidance sheets adapted from UK Silica Essentials guidance sheets by trained workers and supervisors employed in small-scale concrete and masonry demolition operations. A one-page employee silica task-based control guidance sheet for each of four demolition tasks and multiple-page silica control guidance for supervisors were developed. Interactive, hands-on worker training on these task-based good work practice controls was developed. Training was presented to 26 participants from two demolition crews. Feedback on the training and task-based good work practice control guidance sheets was elicited. Observations of work practices were made before and after training. Participants indicated gains in knowledge and checklists were used to document skill attainment. The quality of the training and usefulness of the material/skills was rated high by trainees. Increased use of water to suppress dust and wet cleaning methods on the job were documented following the training. Additional follow-up after training is required to determine long-term impact on sustained changes in work practices, and to evaluate the need for refresher training.

  3. Parasitic worms: knowledge, attitudes, and practices in Western Côte d'Ivoire with implications for integrated control.

    Directory of Open Access Journals (Sweden)

    Cinthia A Acka

    Full Text Available BACKGROUND: In the developing world where parasitic worm infections are pervasive, preventive chemotherapy is the key strategy for morbidity control. However, local knowledge, attitudes, and practices (KAP of parasitic worms are poorly understood, although such information is required for prevention and sustainable control. METHODS: We carried out KAP surveys in two rural communities of Côte d'Ivoire that were subjected to school-based and community-based research and control activities. We used qualitative and quantitative methods. The former included observations, in-depth interviews with key informants, and focus group discussions with school children and adults. Quantitative methods consisted of a structured questionnaire administered to household heads. PRINCIPAL FINDINGS: Access to clean water was lacking in both communities and only a quarter of the households had functioning latrines. There was a better understanding of soil-transmitted helminthiasis than intestinal schistosomiasis, but community-based rather than school-based interventions appeared to improve knowledge of schistosomiasis. In the villages with community-based interventions, three-quarters of household interviewees knew about intestinal schistosomiasis compared to 14% in the village where school-based interventions were implemented (P<0.001. Whereas two-thirds of respondents from the community-based intervention village indicated that the research and control project was the main source of information, only a quarter of the respondents cited the project as the main source. CONCLUSIONS/SIGNIFICANCE: Preventive chemotherapy targeting school-aged children has limitations, as older population segments are neglected, and hence lack knowledge about how to prevent and control parasitic worm infections. Improved access to clean water and sanitation is necessary, along with health education to make a durable impact against helminth infections.

  4. Cross-infection and infection control in dentistry: Knowledge, attitude and practice of patients attended dental clinics in King Abdulaziz University Hospital, Jeddah, Saudi Arabia

    Directory of Open Access Journals (Sweden)

    Nahla K. Ibrahim

    2017-07-01

    Full Text Available The objective of the study was to determine the level of Knowledge, Attitude and Practice (KAP of patients attended dental clinics at King Abdulaziz University Hospital (KAUH regarding cross infections and infection control in dentistry. A cross-sectional study was conducted among 225 patients who attended the dental clinics of KAUH, Jeddah, Saudi Arabia, 2014. A standardized, confidential, anonymous, interviewing questionnaire was used. Knowledge about dental infections was assessed by 12 MCQs. The attitudes were assessed through answering seven statements on a three- point Likert scale. Patients’ self reported practices were also evaluated. Descriptive and inferential statistics were done.Results of the study revealed that 39.5%, 38.7% and 21.8% of the participants obtained poor, fair and satisfactory level of knowledge about infections and infection control in dentistry, respectively. Social media was the commonest source of information about dental infection. Participant's educational level was significantly associated with the level of knowledge about dental infection. Patients had positive attitudes towards infection control in dentistry. Regarding self-reported practice, only few participants would ask dentists about sterilization of dental instruments (9.3%, wearing face mask (13.3% and gloves (16.4% if they don’t do so. In conclusion, our participants had good attitudes towards infection control in dentistry. However, their knowledge and practice need improvements. Conduction of educational programs is needed through social media, mass media, schools and public places. These programs involve both patients and providers. Keywords: Patient safety, Cross infection, Dental infection, Infection control, Emerging diseases, KAP

  5. Plans for a Collaboratively Developed Distributed Control System for the Spallation Neutron Source

    International Nuclear Information System (INIS)

    DeVan, W.R.; Gurd, D.P.; Hammonds, J.; Lewis, S.A.; Smith, J.D.

    1999-01-01

    The Spallation Neutron Source (SNS) is an accelerator-based pulsed neutron source to be built in Oak Ridge, Tennessee. The facility has five major sections - a ''front end'' consisting of a 65 keV H - ion source followed by a 2.5 MeV RFQ; a 1 GeV linac; a storage ring; a 1MW spallation neutron target (upgradeable to 2 MW); the conventional facilities to support these machines and a suite of neutron scattering instruments to exploit them. These components will be designed and implemented by five collaborating institutions: Lawrence Berkeley National Laboratory (Front End), Los Alamos National Laboratory (Linac); Brookhaven National Laboratory (Storage Ring); Argonne National Laboratory (Instruments); and Oak Ridge National Laboratory (Neutron Source and Conventional Facilities). It is proposed to implement a fully integrated control system for all aspects of this complex. The system will be developed collaboratively, with some degree of local autonomy for distributed systems, but centralized accountability. Technical integration will be based upon the widely-used EPICS control system toolkit, and a complete set of hardware and software standards. The scope of the integrated control system includes site-wide timing and synchronization, networking and machine protection. This paper discusses the technical and organizational issues of planning a large control system to be developed collaboratively at five different institutions, the approaches being taken to address those issues, as well as some of the particular technical challenges for the SNS control system

  6. Management practices and controls on methane emissions from sub-tropical wetlands

    Science.gov (United States)

    DeLucia, Nicholas; Casa-Nova Gomez, Nuri; Bernacchi, Carl

    2015-04-01

    It is well documented that green house gas concentrations have risen at unequivocal rates since the industrial revolution but the disparity between anthropogenic sources and natural sources is uncertain. Wetlands are one example of a natural ecosystem that can be a substantial source or sink for methane (CH4) depending on any combination of climate conditions, natural and anthropogenic disturbances, or ecosystem perturbations. Due to strict anaerobic conditions required for CH4-generating microorganisms, natural wetlands are the main source for biogenic CH4. Although wetlands occupy less than 5% of total land surface area, they contribute approximately 20% of total CH4 emissions to the atmosphere. CH4 is one of the most damaging green house gases with current emission estimates ranging from 55 to 231 Tg CH4 yr-1. The processes regulating CH4 emissions are sensitive to land use and management practices of areas surrounding wetlands. Variation in adjacent vegetation or grazing intensity by livestock can, for example, alter CH4 fluxes from wetland soils by altering nutrient balance, carbon inputs and hydrology. Therefore, understanding how these changes will affect wetland source strength is essential to understand the impact of wetland management practices on the global climate system. In this study we quantify wetland methane fluxes from subtropical wetlands on a working cattle ranch in central Florida near Okeechobee Lake (27o10'52.04"N, 81o21'8.56"W). To determine differences in CH4 fluxes associated with land use and management, a replicated (n = 4) full factorial experiment was designed for wetlands where the surrounding vegetation was (1) grazed or un-grazed and (2) composed of native vegetation or improved pasture. Net exchange of CH4 and CO2 between the land surface and the atmosphere were sampled with a LICOR Li-7700 open path CH4 analyzer and Li-7500A open path CO2/H20 analyzer mounted in a 1-m3 static gas-exchange chamber. Our results showed and verified

  7. Mechanisms of Practice-Related Reductions of Dual-Task Interference with Simple Tasks: Data and Theory

    Science.gov (United States)

    Strobach, Tilo; Torsten, Schubert

    2017-01-01

    In dual-task situations, interference between two simultaneous tasks impairs performance. With practice, however, this impairment can be reduced. To identify mechanisms leading to a practice-related improvement in sensorimotor dual tasks, the present review applied the following general hypothesis: Sources that impair dual-task performance at the beginning of practice are associated with mechanisms for the reduction of dual-task impairment at the end of practice. The following types of processes provide sources for the occurrence of this impairment: (a) capacity-limited processes within the component tasks, such as response-selection or motor response stages, and (b) cognitive control processes independent of these tasks and thus operating outside of component-task performance. Dual-task practice studies show that, under very specific conditions, capacity-limited processes within the component tasks are automatized with practice, reducing the interference between two simultaneous tasks. Further, there is evidence that response-selection stages are shortened with practice. Thus, capacity limitations at these stages are sources for dual-task costs at the beginning of practice and are overcome with practice. However, there is no evidence demonstrating the existence of practice-related mechanisms associated with capacity-limited motor-response stages. Further, during practice, there is an acquisition of executive control skills for an improved allocation of limited attention resources to two tasks as well as some evidence supporting the assumption of improved task coordination. These latter mechanisms are associated with sources of dual-task interference operating outside of component task performance at the beginning of practice and also contribute to the reduction of dual-task interference at its end. PMID:28439319

  8. Controlling radioactive sources. Stronger 'cradle-to-grave' security needed, IAEA says

    International Nuclear Information System (INIS)

    2002-01-01

    This article highlights the IAEA activities in the field of radiation safety and security of radiation sources and other radioactive materials in its Member States. The IAEA has been active in lending its expertise to search out and secure orphaned sources in several countries. Additionally more than 70 States have joined with the IAEA to collect and share information on trafficking incidents and other unauthorized movements of radioactive sources and other radioactive materials. In March 2002 the IAEA Board of Governors approved a multi-faceted Action plan to Combat Nuclear Terrorism that includes upgrading radiation safety and security. One programme is designed to ensure that significant, uncontrolled radioactive sources are brought under regulatory control and properly secured by providing assistance to Member States in their efforts to identify, locate and secure or dispose of orphan sources

  9. Reported and observed controlling feeding practices predict child eating behavior after 12 months.

    Science.gov (United States)

    Bergmeier, Heidi J; Skouteris, Helen; Haycraft, Emma; Haines, Jess; Hooley, Merrilyn

    2015-06-01

    Controlling feeding practices are linked to children's self-regulatory eating practices and weight status. Maternal reports of controlling feeding practices are not always significantly related to independently rated mealtime observations. However, prior studies only assessed 1 mealtime observation, which may not be representative of typical mealtime settings or routines. The first aim was to examine associations between reported and observed maternal pressure to eat and restriction feeding practices at baseline (T1) and after ∼ 12 mo (T2). The second aim was to evaluate relations between maternal and child factors [e.g., concern about child weight, child temperament, child body mass index (BMI)-for-age z scores (BMIz)] at T1 and reported and observed maternal pressure to eat and restriction feeding practices (T1 and T2). The third aim was to assess prospective associations between maternal feeding practices (T1) and child eating behaviors (T2) and child BMIz (T2). A sample of 79 mother-child dyads in Victoria, Australia, participated in 2 lunchtime home observations (T1 and T2). BMI measures were collected during the visits. Child temperament, child eating behaviors, maternal parenting styles, and maternal feeding practices were evaluated at T1 and T2 via questionnaires. Associations were assessed with Pearson's correlation coefficients, paired t tests, and hierarchical regressions. Reported restriction (T1) was inversely associated with observed restriction at T1 (r = -0.24, P controlling strategies. © 2015 American Society for Nutrition.

  10. Access control and interlock system at the Advanced Photon Source

    International Nuclear Information System (INIS)

    Forrestal, J.; Hogrefe, R.; Knott, M.; McDowell, W.; Reigle, D.; Solita, L.; Koldenhoven, R.; Haid, D.

    1997-01-01

    The Advanced Photon Source (APS) consists of a linac, position accumulator ring (PAR), booster synchrotron, storage ring, and up to 70 experimental beamlines. The Access Control and Interlock System (ACIS) utilizes redundant programmable logic controllers (PLCs) and a third hard-wired chain to protect personnel from prompt radiation generated by the linac, PAR, synchrotron, and storage ring. This paper describes the ACIS's design philosophy, configuration, hardware, functionality, validation requirements, and operational experience

  11. Radiopharmaceuticals good practices handbook: ARCAL XV radiopharmaceuticals control and production

    International Nuclear Information System (INIS)

    Verdera Presto, Silvia

    1998-01-01

    A safety practice of the therapeutics diagnostic proceeding in nuclear medicine require a permanent provide high quality radiopharmaceuticals manufacture. This work treat to give a guide for all radio pharmacies laboratories that produce,control, fraction and or dispense radiopharmaceuticals products, with attention hospitable radiopharmacy laboratory. Three chapters with recommendations in manufacture good practice in Hospital radiopharmacy, industrial centralized, bibliography and three annexe's about clean area classification,standards work in laminar flux bell, and guarantee and cleaning areas

  12. 40 CFR 450.24 - New source performance standards reflecting the best available demonstrated control technology...

    Science.gov (United States)

    2010-07-01

    ... performance standards reflecting the best available demonstrated control technology (NSPS). Any new source... 40 Protection of Environment 29 2010-07-01 2010-07-01 false New source performance standards reflecting the best available demonstrated control technology (NSPS). 450.24 Section 450.24 Protection of...

  13. Sources of ionizing radiation in industry: licensing and control

    International Nuclear Information System (INIS)

    Dimitrov, V.

    2001-01-01

    In this paper are presented several methods, which the Inspection on the Safe Use of Atomic Energy applies for the control on the use of sources of ionizing radiation in industry. It reviews some problems, which we have to solve during our inspections. An analysis and assessment of them is done. The prescribed safety ensuring measures are discussed. (author)

  14. Mind-Body Practice Changes Fractional Amplitude of Low Frequency Fluctuations in Intrinsic Control Networks

    Directory of Open Access Journals (Sweden)

    Gao-Xia Wei

    2017-07-01

    Full Text Available Cognitive control impairment is a typical symptom largely reported in populations with neurological disorders. Previous studies have provided evidence about the changes in cognitive control induced by mind-body training. However, the neural correlates underlying the effect of extensive mind-body practice on cognitive control remain largely unknown. Using resting-state functional magnetic resonance imaging, we characterized dynamic fluctuations in large-scale intrinsic connectivity networks associated with mind-body practice, and examined their differences between healthy controls and Tai Chi Chuan (TCC practitioners. Compared with a control group, the TCC group revealed significantly decreased fractional Amplitude of Low Frequency Fluctuations (fALFF in the bilateral frontoparietal network, default mode network and dorsal prefrontal-angular gyri network. Furthermore, we detected a significant association between mind-body practice experience and fALFF in the default mode network, as well as an association between cognitive control performance and fALFF of the frontoparietal network. This provides the first evidence of large-scale functional connectivity in brain networks associated with mind-body practice, shedding light on the neural network changes that accompany intensive mind-body training. It also highlights the functionally plastic role of the frontoparietal network in the context of the “immune system” of mental health recently developed in relation to flexible hub theory.

  15. Mind-Body Practice Changes Fractional Amplitude of Low Frequency Fluctuations in Intrinsic Control Networks.

    Science.gov (United States)

    Wei, Gao-Xia; Gong, Zhu-Qing; Yang, Zhi; Zuo, Xi-Nian

    2017-01-01

    Cognitive control impairment is a typical symptom largely reported in populations with neurological disorders. Previous studies have provided evidence about the changes in cognitive control induced by mind-body training. However, the neural correlates underlying the effect of extensive mind-body practice on cognitive control remain largely unknown. Using resting-state functional magnetic resonance imaging, we characterized dynamic fluctuations in large-scale intrinsic connectivity networks associated with mind-body practice, and examined their differences between healthy controls and Tai Chi Chuan (TCC) practitioners. Compared with a control group, the TCC group revealed significantly decreased fractional Amplitude of Low Frequency Fluctuations (fALFF) in the bilateral frontoparietal network, default mode network and dorsal prefrontal-angular gyri network. Furthermore, we detected a significant association between mind-body practice experience and fALFF in the default mode network, as well as an association between cognitive control performance and fALFF of the frontoparietal network. This provides the first evidence of large-scale functional connectivity in brain networks associated with mind-body practice, shedding light on the neural network changes that accompany intensive mind-body training. It also highlights the functionally plastic role of the frontoparietal network in the context of the "immune system" of mental health recently developed in relation to flexible hub theory.

  16. Menstrual Hygiene Practices and Sources of Menstrual Hygiene Information among Adolescent Secondary School Girls in Abakaliki Education Zone of Ebonyi State

    Science.gov (United States)

    Ilo, Cajetan I.; Nwimo, Ignatius O.; Onwunaka, Chinagorom

    2016-01-01

    Menstruation is clouded by socio-cultural restrictions resulting in adolescent girls remaining ignorant of hygienic practices. The study was designed to ascertain the menstrual hygiene practices and sources of menstrual hygiene information among 1200 adolescent secondary school girls, who completed the questionnaire designed for the study. Out of…

  17. Astronaut Dale Gardner rehearses control of MMU during EVA practice

    Science.gov (United States)

    1984-01-01

    Astronaut Dale A. Gardner, 51-A mission specialist, rehearses control of manned maneuvering unit (MMU) during a practice for an extravehicular activity (EVA). Gardner is in the Shuttle mockup and integration laboratory at JSC.

  18. Deghosting, Demultiple, and Deblurring in Controlled-Source Seismic Interferometry

    Directory of Open Access Journals (Sweden)

    Joost van der Neut

    2011-01-01

    Full Text Available With controlled-source seismic interferometry we aim to redatum sources to downhole receiver locations without requiring a velocity model. Interferometry is generally based on a source integral over cross-correlation (CC pairs of full, perturbed (time-gated, or decomposed wavefields. We provide an overview of ghosts, multiples, and spatial blurring effects that can occur for different types of interferometry. We show that replacing cross-correlation by multidimensional deconvolution (MDD can deghost, demultiple, and deblur retrieved data. We derive and analyze MDD for perturbed and decomposed wavefields. An interferometric point spread function (PSF is introduced that can be obtained directly from downhole data. Ghosts, multiples, and blurring effects that may populate the retrieved gathers can be locally diagnosed with the PSF. MDD of perturbed fields can remove ghosts and deblur retrieved data, but it leaves particular multiples in place. To remove all overburden-related effects, MDD of decomposed fields should be applied.

  19. Systematic review on international practices in controlling waterpipe tobacco smoking.

    Science.gov (United States)

    Tee, Guat Hiong; Hairi, Noran N; Nordin, Fauziah; Choo, Wan Yuen; Chan, Ying Ying; Kaur, Gurpreet; Veerasingam, Pathma Devi; Bulgiba, Awang

    2015-01-01

    Waterpipe tobacco smoking has becoming popular especially among young people worldwide. Smokers are attracted by its sweeter, smoother smoke, social ambience and the misconception of reduced harm. The objective of this study was to systematically review the effects of waterpipe tobacco policies and practices in reducing its prevalence. A systematic review was conducted electronically using the PubMed, OVID, Science Direct, Proquest and Embase databases. All possible studies from 1980 to 2013 were initially screened based on titles and abstracts. The selected articles were subjected to data extraction and quality rating. Three studies met the inclusion criteria and were eligible for this review. Almost all of the waterpipe tobacco products and its accessories did not comply with the regulations on health warning labelling practices as stipulated under Article 11 of WHO FCTC. In addition, the grisly new warning labels for cigarettes introduced by Food and Drug Administration did not affect hookah tobacco smoking generally. Indoor air quality in smoking lounges was found to be poor and some hookah lounges were operated without smoke shop certification. Our findings revealed the availability of minimal information on the practices in controlling waterpipe smoking in reducing its prevalence. The lack of comprehensive legislations or practices in controlling waterpipe smoking warrants further research and policy initiatives to curb this burgeoning global epidemic, especially among the vulnerable younger population.

  20. Stabilization of microgrid with intermittent renewable energy sources by SMES with optimal coil size

    International Nuclear Information System (INIS)

    Saejia, M.; Ngamroo, I.

    2011-01-01

    A controller design of a superconducting magnetic energy storage unit is proposed. The structure of a power controller is the practical proportional-integral (PI). The PI parameters and coil size are tuned by a particle swarm optimization. The proposed method is able to effectively alleviate power fluctuations. It is well known that the superconducting coil is the vital part of a superconducting magnetic energy storage (SMES) unit. This paper deals with the power controller design of a SMES unit with an optimal coil size for stabilization of an isolated microgrid. The study microgrid consists of renewable energy sources with intermittent power outputs i.e., wind and photovoltaic. Since power generations from such renewable sources are unpredictable and variable, these result in power fluctuations in a microgrid. To stabilize power fluctuations, a SMES unit with a fast control of active and reactive power can be applied. The structure of a power controller is the practical proportional-integral (PI). Based on the minimization of the variance of power fluctuations from renewable sources as well as the initial stored energy of SMES, the optimal PI parameters and coil size are automatically and simultaneously tuned by a particle swarm optimization. Simulation studies show that the proposed SMES controller with an optimal coil size is able to effectively alleviate power fluctuations under various power patterns from intermittent renewable sources.

  1. Stabilization of microgrid with intermittent renewable energy sources by SMES with optimal coil size

    Energy Technology Data Exchange (ETDEWEB)

    Saejia, M., E-mail: samongkol@gmail.com [School of Electrical Engineering, Faculty of Engineering, King Mongkut' s Institute of Technology Ladkrabang, Bangkok 10520 (Thailand); Ngamroo, I. [School of Electrical Engineering, Faculty of Engineering, King Mongkut' s Institute of Technology Ladkrabang, Bangkok 10520 (Thailand)

    2011-11-15

    A controller design of a superconducting magnetic energy storage unit is proposed. The structure of a power controller is the practical proportional-integral (PI). The PI parameters and coil size are tuned by a particle swarm optimization. The proposed method is able to effectively alleviate power fluctuations. It is well known that the superconducting coil is the vital part of a superconducting magnetic energy storage (SMES) unit. This paper deals with the power controller design of a SMES unit with an optimal coil size for stabilization of an isolated microgrid. The study microgrid consists of renewable energy sources with intermittent power outputs i.e., wind and photovoltaic. Since power generations from such renewable sources are unpredictable and variable, these result in power fluctuations in a microgrid. To stabilize power fluctuations, a SMES unit with a fast control of active and reactive power can be applied. The structure of a power controller is the practical proportional-integral (PI). Based on the minimization of the variance of power fluctuations from renewable sources as well as the initial stored energy of SMES, the optimal PI parameters and coil size are automatically and simultaneously tuned by a particle swarm optimization. Simulation studies show that the proposed SMES controller with an optimal coil size is able to effectively alleviate power fluctuations under various power patterns from intermittent renewable sources.

  2. Design of Programmable LED Controller with a Variable Current Source for 3D Image Display

    Directory of Open Access Journals (Sweden)

    Kyung-Ryang Lee

    2014-12-01

    Full Text Available Conventional fluorescent light sources, as well as incandescent light sources are gradually being replaced by Light Emitting Diodes (LEDs for reducing power consumption in the image display area for multimedia application. An LED light source requires a controller with a low-power operation. In this paper, a low-power technique using adiabatic operation is applied for the implementation of LED controller with a stable constant-current, a low-power and low-heat function. From the simulation result, the power consumption of the proposed LED controller using adiabatic operation was reduced to about 87% in comparison with conventional operation with a constant VDD. The proposed circuit is expected to be an alternative LED controller which is sensitive to external conditions such as heat.

  3. Are parenting style and controlling feeding practices related?

    Science.gov (United States)

    Blissett, J; Haycraft, E

    2008-01-01

    This study examined the relationships between parenting styles, feeding practices and BMI in a non-clinical sample of mothers and fathers of UK preschool children. Ninety-six cohabiting parents of 48 children (19 male, 29 female, mean age 42 months) completed a series of self-report questionnaires assessing parenting style, feeding practices, eating psychopathology and a range of demographic information. There were no relationships between authoritarian parenting and controlling feeding practices. In both mothers and fathers, permissive parenting style was related to lower monitoring of children's unhealthy food intake. Permissive parenting was also associated with increased use of restriction by mothers and pressure to eat by fathers. Authoritative parenting style was also related to lower use of pressure to eat by fathers only. Parenting styles were not related to child BMI in this sample. Higher child BMI was best predicted by lower paternal application of pressure to eat and greater paternal reports of drive for thinness. Parenting style may not have a direct impact on child BMI until child food selection and consumption becomes more autonomous.

  4. Procedures for identifying reasonably available control technology for stationary sources of PM-10. Final report

    International Nuclear Information System (INIS)

    Fitzpatrick, M.J.; Ellefson, R.

    1992-09-01

    The guidance document sets forth procedures and identifies sources of information that will assist State and local air pollution control agencies in determining Reasonably Available Control Technology (RACT) for PM-10 (particulate matter having a nominal aerometric diameter of 10 microns or less) emission from existing stationary sources on a case-by-case basis. It provides an annotated bibliography of documents to aid in identifying the activities that cause PM-10 emissions as well as applicable air pollution control measures and their effectiveness in reducing emissions. The most stringent state total particulate matter (PM) emission limits are identified for several categories of PM-10 sources and compared to available emission test data. Finally, guidance is provided on procedures for estimating total capital investment and total annual cost of the control measures which are generally used to control PM-10 emissions

  5. Contrasting Proprietary and Free/Open Source Game Development

    Directory of Open Access Journals (Sweden)

    Marco Zamarian

    2008-10-01

    Full Text Available Free/Libre Open Source Software (F/LOSS development practices are gaining momentum in the computer game industry. This traditionally proprietary industry is becoming more interested in the F/LOSS paradigm for developing complex software projects. Software practitioners, both managers and developers, need to understand the potential in order to benefit properly from incorporating F/LOSS practices into their proprietary production cycle. Comparisons between proprietary and F/LOSS software development processes are usually characterized in terms of the relationship between property rights, revenue distribution and power within a network of actors. By contrast, coordination and control practices, mediating artifacts and development tools, and the interactions between the different actors involved in the development are often neglected. Proprietary and F/LOSS development differ in terms of the knowledge exchanges between the relevant actors and the different strategies employed to overcome information asymmetries. Recognizing this difference is an essential step for evaluating how proprietary, closed-source software houses can benefit by integrating various F/LOSS practices into their development agenda.

  6. Stability analysis of direct current control in current source rectifier

    DEFF Research Database (Denmark)

    Lu, Dapeng; Wang, Xiongfei; Blaabjerg, Frede

    2017-01-01

    Current source rectifier with high switching frequency has a great potential for improving the power efficiency and power density in ac-dc power conversion. This paper analyzes the stability of direct current control based on the time delay effect. Small signal model including dynamic behaviors...

  7. Practical controller design for ultra-precision positioning of stages with a pneumatic artificial muscle actuator

    Science.gov (United States)

    Tang, T. F.; Chong, S. H.

    2017-06-01

    This paper presents a practical controller design method for ultra-precision positioning of pneumatic artificial muscle actuator stages. Pneumatic artificial muscle (PAM) actuators are safe to use and have numerous advantages which have brought these actuators to wide applications. However, PAM exhibits strong non-linear characteristics, and these limitations lead to low controllability and limit its application. In practice, the non-linear characteristics of PAM mechanism are difficult to be precisely modeled, and time consuming to model them accurately. The purpose of the present study is to clarify a practical controller design method that emphasizes a simple design procedure that does not acquire plants parameters modeling, and yet is able to demonstrate ultra-precision positioning performance for a PAM driven stage. The practical control approach adopts continuous motion nominal characteristic trajectory following (CM NCTF) control as the feedback controller. The constructed PAM driven stage is in low damping characteristic and causes severe residual vibration that deteriorates motion accuracy of the system. Therefore, the idea to increase the damping characteristic by having an acceleration feedback compensation to the plant has been proposed. The effectiveness of the proposed controller was verified experimentally and compared with a classical PI controller in point-to-point motion. The experiment results proved that the CM NCTF controller demonstrates better positioning performance in smaller motion error than the PI controller. Overall, the CM NCTF controller has successfully to reduce motion error to 3µm, which is 88.7% smaller than the PI controller.

  8. A Conceptual Framework for Primary Source Practices

    Science.gov (United States)

    Ensminger, David C.; Fry, Michelle L.

    2012-01-01

    This article introduces a descriptive conceptual framework to provide teachers with a means of recognizing and describing instructional activities that use primary sources. The framework provides structure for professional development programs that have been established to train teachers to access and integrate primary sources into lessons. The…

  9. A Self-Assessment of the Effectiveness to Control Radiation Sources in Sierra Leone

    Energy Technology Data Exchange (ETDEWEB)

    Bun-Tejan, Umaru Remilekun [KAIST, Daejeon (Korea, Republic of); Lee, Byung Soo [Korea Institute of Nuclear Safety, Daejeon (Korea, Republic of)

    2016-10-15

    There is an urgent need to effectively control sources of ionizing radiation. Sources of ionizing radiation pose serious occupational, public health, and environmental consequences, if not properly controlled. The government of Sierra Leone knows the importance of controlling these sources of ionizing radiation and of establishing an independent Nuclear Safety Infrastructure. Sierra Leone has no nuclear facilities but, it is rapidly developing its infrastructure in order to obtain nuclear technology. However, the regulatory effectiveness in controlling radiation risk is essential for the International Atomic Energy Agency to allow the transfer of nuclear technology. For this reason, this study will evaluate the status of the regulatory authority in Sierra Leone to control radiation risk. The International Atomic Energy Agency (IAEA) review mission to Sierra Leone found that the RPBA did not give sufficient enforcement powers to the Board Secretariat. The research evaluated the status of the regulatory authority of Sierra Leone. The status of the regulatory authority was evaluated against several parameters including management systems, regulatory processes, authorization, inspection, and enforcement. The ability to effectively control ionizing radiation sources depends on the status of the regulatory body. The Integrated Regulatory Review Service Report on Sierra Leone led us to infer that there is a need for the regulatory authority to rapidly improve its ability to control ionizing radiation sources in the country. The findings however, revealed that the overall strengths of the regulatory body in Sierra Leone slightly outnumber the weaknesses. Management systems have a ratio of 0.85:1 of strengths to weaknesses. This ratio makes management systems the weakest parameter evaluated. Thus there is need for stronger collaboration between management staff. The Regulatory processes have a ratio of 1.3:1, authorizations have a ratio of 4.3:1, inspections have ratio of 2

  10. A Self-Assessment of the Effectiveness to Control Radiation Sources in Sierra Leone

    International Nuclear Information System (INIS)

    Bun-Tejan, Umaru Remilekun; Lee, Byung Soo

    2016-01-01

    There is an urgent need to effectively control sources of ionizing radiation. Sources of ionizing radiation pose serious occupational, public health, and environmental consequences, if not properly controlled. The government of Sierra Leone knows the importance of controlling these sources of ionizing radiation and of establishing an independent Nuclear Safety Infrastructure. Sierra Leone has no nuclear facilities but, it is rapidly developing its infrastructure in order to obtain nuclear technology. However, the regulatory effectiveness in controlling radiation risk is essential for the International Atomic Energy Agency to allow the transfer of nuclear technology. For this reason, this study will evaluate the status of the regulatory authority in Sierra Leone to control radiation risk. The International Atomic Energy Agency (IAEA) review mission to Sierra Leone found that the RPBA did not give sufficient enforcement powers to the Board Secretariat. The research evaluated the status of the regulatory authority of Sierra Leone. The status of the regulatory authority was evaluated against several parameters including management systems, regulatory processes, authorization, inspection, and enforcement. The ability to effectively control ionizing radiation sources depends on the status of the regulatory body. The Integrated Regulatory Review Service Report on Sierra Leone led us to infer that there is a need for the regulatory authority to rapidly improve its ability to control ionizing radiation sources in the country. The findings however, revealed that the overall strengths of the regulatory body in Sierra Leone slightly outnumber the weaknesses. Management systems have a ratio of 0.85:1 of strengths to weaknesses. This ratio makes management systems the weakest parameter evaluated. Thus there is need for stronger collaboration between management staff. The Regulatory processes have a ratio of 1.3:1, authorizations have a ratio of 4.3:1, inspections have ratio of 2

  11. Shielding practice

    International Nuclear Information System (INIS)

    Sauermann, P.F.

    1985-08-01

    The basis of shielding practice against external irradiation is shown in a simple way. For most sources of radiation (point sources) occurring in shielding practice, the basic data are given, mainly in the form of tables, which are required to solve the shielding problems. The application of these data is explained and discussed using practical examples. Thickness of shielding panes of glove boxes for α and β radiation; shielding of sealed γ-radiography sources; shielding of a Co-60 radiation source, and of the manipulator panels for hot cells; damping factors for γ radiation and neutrons; shielding of fast and thermal neutrons, and of bremsstrahlung (X-ray tubes, Kr-85 pressure gas cylinders, 42 MeV betatrons, 20 MeV linacs); two-fold shielding (lead glass windows for hot cells, 14 MeV neutron generators); shielding against scattered radiation. (orig./HP) [de

  12. Reducing Uncontrolled Radioactive Sources through Tracking and Training: US Environmental Protection Agency Initiatives

    Energy Technology Data Exchange (ETDEWEB)

    Kopsick, D.A., E-mail: kopsick.deborah@epa.gov [US Environmental Protection Agency, Washington, DC (United States)

    2011-07-15

    The international metal processing industries are very concerned about the importation of scrap metal contaminated with radioactive materials. When radioactive sources fall out of regulatory control, improper handling can cause serious injury and death. There is no one way to address this problem and various US governmental and industry entities have developed radiation source control programmes that function within their authorities. The US Environmental Protection Agency's (EPA) mission is to protect public health and the environment. To ensure this protection, EPA's approach to orphan sources in scrap metal has focused on regaining control of lost sources and preventing future losses. EPA has accomplished this through a number of avenues including training development, product stewardship, identification of non-radiation source alternatives, physical tagging of sources, field testing of innovative radiation detection instrumentation and development of international best practices. In order to achieve its goal of enhanced control on contaminated scrap metal and orphaned radioactive sources, EPA has forged alliances with the metals industry, other Federal agencies, state governments and the IAEA. (author)

  13. Android and the political economy of the mobile Internet: A renewal of open source critique

    NARCIS (Netherlands)

    Spreeuwenberg, K.; Poell, T.

    2012-01-01

    This paper examines how and why Google in developing Android, the popular mobile operating system, has strategically adopted particular open source practices, but ignored others. It explores how through these practices, the corporation has been able to cultivate and control a vast mobile Internet

  14. Guidelines for the practice of radiopharmacy

    International Nuclear Information System (INIS)

    1988-05-01

    The main objective of the guidelines is to establish minimum standards for the practice of radiopharmacy in Australia and New Zealand. The guidelines are intended to provide a basis for the safe and efficient practice of radiopharmacy in a hospital or clinical environment. They cover premises in which radiopharmacy is practised; procurement and use of sealed and unsealed radioactive sources; radiopharmaceutical HOT LAB dose preparation; routine quality control procedures; dispensing of radiopharmaceuticals; distribution of radiopharmaceuticals; record keeping; basic radiation protection procedures; consultation and education; research and development; and the preparation of sterile radiopharmaceuticals

  15. Standards and the design of the advanced photon source control system

    International Nuclear Information System (INIS)

    McDowell, W.P.; Knott, M.J.; Lenkszus, F.R.

    1992-01-01

    The Advanced Photon Source (APS), now under construction at Argonne National Laboratory (ANL), is a 7 GeV positron storage ring dedicated to research facilities using synchrotron radiation. This ring, along with its injection accelerators is to be controlled and monitored with a single, flexible, and expandable control system. This paper will cover the present status of the APS control system as well as discuss the design decisions which led us to use industrial standards and collaborations with other laboratories whenever possible to develop a control system. It will explain the APS control system and illustrate how the use of standards has allowed APS to design a control system whose implementation addresses these issues. (J.P.N.)

  16. Influence of mental practice on development of voluntary control of a novel motor acquisition task.

    Science.gov (United States)

    Creelman, Jim

    2003-08-01

    The purpose of this investigation was to assess whether mental practice facilitates the development of voluntary control over the recruitment of the abductor hallucis muscle to produce isolated big toe abduction. A sample of convenience of 15 women and 20 men with a mean age of 28.8 yr. (SD=5.7) and healthy feet, who were unable voluntarily to abduct the big toe, were randomly assigned to one of three groups, a mental practice group, a physical practice group, and a group who performed a control movement during practice. Each subject received neuromuscular electrical stimulation to introduce the desired movement prior to each of five practice bouts over a single session lasting 2 hr. Big toe abduction active range of motion and surface electromyographic (EMG) output of the abductor hallucis and extensor digitorum brevis muscles were measured prior to the first practice bout and following each practice bout, yielding seven acquisition trials. Acquisition is defined as an improvement in both active range of motion and in the difference between the integrated EMG of the abductor hallucis and extensor digitorum brevis muscles during successive acquisition trials. Seven members of both the mental and physical practice groups and one member of the control group met the acquisition criteria. Chi-square analysis indicated the group difference was statistically significant, suggesting mental practice was effective for this task.

  17. Improvement of proton source based on cylindrical inertial electrostatic confinement fusion with ion source

    International Nuclear Information System (INIS)

    Yamauchi, Kunihito; Ohura, Sonoe; Tashiro, Atsushi; Watanabe, Masato; Okino, Akitoshi; Kohno, Toshiyuki; Hotta, Eiki; Yuura, Morimasa

    2005-01-01

    Inertial Electrostatic Confinement Fusion (IECF) device is a compact fusion proton/neutron source with an extremely simple configuration, high controllability, and hence high safety. Therefore, it has been studied for practical use as a portable neutron/proton source for various applications such as landmine detection and medical positron emission tomography. However, some problems remain for the practical use, and the most critical one is the insufficiency of absolute neutron/proton yields. In this study, a new IECF device was designed and tested to obtain high neutron/proton yields. The key features of the new device are the cylindrical electrode configuration in consideration of better electrostatic confinement of ions and extraction of protons, and an integrated ion source that consists of sixteen ferrite magnets and biasing the grid anode. To investigate the performance characteristics of the device and the effect of the ion source, three kinds of experimental setup were used for comparison. At first, the device was operated with the basic setup. Then a cusp magnetic field was applied by using ferrite magnets, and the grid anode was negatively biased. As a result, it was confirmed that the ion source works effectively. At the same voltage and current, the obtained neutron production rate was about one order of magnitude higher than that of the conventional spherical IECF device. The maximum neutron production rate of 6.8x10 9 n/s was obtained at a pulsed discharge of -70 kV and 10 A with an anode bias voltage of -1.0 kV. (author)

  18. 76 FR 29756 - Healthcare Infection Control Practices Advisory Committee (HICPAC)

    Science.gov (United States)

    2011-05-23

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Healthcare... Director, Division of Healthcare Quality Promotion regarding (1) The practice of healthcare infection... infections), antimicrobial resistance, and related events in settings where healthcare is provided; and (3...

  19. 77 FR 4820 - Healthcare Infection Control Practices Advisory Committee (HICPAC)

    Science.gov (United States)

    2012-01-31

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Healthcare... the Director, Division of Healthcare Quality Promotion regarding (1) the practice of healthcare... infections), antimicrobial resistance, and related events in settings where healthcare is provided; and (3...

  20. 76 FR 63622 - Healthcare Infection Control Practices Advisory Committee, (HICPAC)

    Science.gov (United States)

    2011-10-13

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Healthcare... Director, Division of Healthcare Quality Promotion regarding (1) The practice of healthcare infection... infections), antimicrobial resistance, and related events in settings where healthcare is provided; and (3...

  1. 77 FR 28392 - Healthcare Infection Control Practices Advisory Committee (HICPAC)

    Science.gov (United States)

    2012-05-14

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Healthcare... the Director, Division of Healthcare Quality Promotion regarding 1) the practice of healthcare... infections), antimicrobial resistance, and related events in settings where healthcare is provided; and 3...

  2. 75 FR 29772 - Healthcare Infection Control Practices Advisory Committee, (HICPAC)

    Science.gov (United States)

    2010-05-27

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Healthcare... Emerging and Zoonotic Infectious Diseases (NCEZID) regarding (1) The practice of healthcare infection... infections), antimicrobial resistance, and related events in settings where healthcare is provided; and (3...

  3. Dealing with Non-Controlling Shareholders : Issues and Best Practice

    OpenAIRE

    World Bank

    2006-01-01

    There is ample evidence today that demanding best practice standards of good corporate governance and convincing enforcement processes lead to higher market valuations of enterprises in free capital markets. This paper contains the following headings: key prerequisites for success with non-controlling shareholders; institutional investors have a fiduciary duty to act convincingly in the in...

  4. Stability and vibration control in synchrotron light source buildings

    Energy Technology Data Exchange (ETDEWEB)

    Godel, J.B.

    1991-01-01

    Synchrotron light sources have undergone three generations of development in the last two decades. The National Synchrotron Light Source (NSLS) at Brookhaven National Laboratory has two second generation'' storage rings that currently provide the world's most intense sources of photons in the VUV and X-ray spectral ranges. There are almost 90 beam lines serving a community of 2600 scientists from 370 institutions. They are engaged in basic and applied research in physics, chemistry, biology, medicine, materials science and various technologies. When design of the NSLS began in 1977, emphasis was given to the stability of the concrete slab on which the storage rings and experimental beam lines were placed. Stability is the result of controlling: vibration from sources internal and external to the building, thermal effects of air and water temperature variations, foundation settlement and contact between the slab and underlying subsoil. With the advent of new research where highly focused beams of x-rays must be placed on increasingly smaller targets located 35 meters or more from the source, and the development of x-ray lithography with resolutions approaching 0.1 micron at chip exposure stations, even greater attention to stability is required in building designs. This paper will review the results of the successful NSLS experience and give an integrated design approach that includes elements which contribute to instabilities, and the means available to reduce them to acceptable levels.

  5. Stability and vibration control in synchrotron light source buildings

    Energy Technology Data Exchange (ETDEWEB)

    Godel, J.B.

    1991-12-31

    Synchrotron light sources have undergone three generations of development in the last two decades. The National Synchrotron Light Source (NSLS) at Brookhaven National Laboratory has two ``second generation`` storage rings that currently provide the world`s most intense sources of photons in the VUV and X-ray spectral ranges. There are almost 90 beam lines serving a community of 2600 scientists from 370 institutions. They are engaged in basic and applied research in physics, chemistry, biology, medicine, materials science and various technologies. When design of the NSLS began in 1977, emphasis was given to the stability of the concrete slab on which the storage rings and experimental beam lines were placed. Stability is the result of controlling: vibration from sources internal and external to the building, thermal effects of air and water temperature variations, foundation settlement and contact between the slab and underlying subsoil. With the advent of new research where highly focused beams of x-rays must be placed on increasingly smaller targets located 35 meters or more from the source, and the development of x-ray lithography with resolutions approaching 0.1 micron at chip exposure stations, even greater attention to stability is required in building designs. This paper will review the results of the successful NSLS experience and give an integrated design approach that includes elements which contribute to instabilities, and the means available to reduce them to acceptable levels.

  6. Stability and vibration control in synchrotron light source buildings

    International Nuclear Information System (INIS)

    Godel, J.B.

    1991-01-01

    Synchrotron light sources have undergone three generations of development in the last two decades. The National Synchrotron Light Source (NSLS) at Brookhaven National Laboratory has two ''second generation'' storage rings that currently provide the world's most intense sources of photons in the VUV and X-ray spectral ranges. There are almost 90 beam lines serving a community of 2600 scientists from 370 institutions. They are engaged in basic and applied research in physics, chemistry, biology, medicine, materials science and various technologies. When design of the NSLS began in 1977, emphasis was given to the stability of the concrete slab on which the storage rings and experimental beam lines were placed. Stability is the result of controlling: vibration from sources internal and external to the building, thermal effects of air and water temperature variations, foundation settlement and contact between the slab and underlying subsoil. With the advent of new research where highly focused beams of x-rays must be placed on increasingly smaller targets located 35 meters or more from the source, and the development of x-ray lithography with resolutions approaching 0.1 micron at chip exposure stations, even greater attention to stability is required in building designs. This paper will review the results of the successful NSLS experience and give an integrated design approach that includes elements which contribute to instabilities, and the means available to reduce them to acceptable levels

  7. Challenges in Regulating Radiation Sources and Associated Waste Management

    International Nuclear Information System (INIS)

    Shehzad, A.

    2016-01-01

    Radiation sources are widely used in the fields of medical, industry, agriculture, research, etc. Owing to the inherent risk of exposure to ionizing radiations while using the radiation sources and management of associated waste, safety measures are of utmost importance including robust regulatory control. Pakistan Nuclear Regulatory Authority (PNRA) is responsible for supervising all matters pertaining to nuclear safety and radiation protection in the country. Since its inception, PNRA has made rigorous efforts to regulate the radiation facilities for which regulatory framework was further strengthened by taking into account international norms/practices and implemented afterwards. However, due to vibrant use of these facilities, there are numerous challenges being faced while implementing the regulatory framework. These challenges pertains to shielding design of some facilities, control over service provider for QC/repair maintenance of radiation equipment, assessment of patient doses, and establishment of national diagnostic reference levels for radiological procedures. Further, the regulatory framework also delineate requirements to minimize the generation of associated radioactive waste as low as practicable. The requirements also necessitates that certain sealed radioactive sources (SRS) are returned to the supplier upon completion of their useful life, while other radioactive sources are required to be transported for storage at designated radioactive waste storage facilities in the country, which requires commitment from the licensee. This paper will briefly describe the challenges in regulating the radiation sources and issues related to the waste management associated with these facilities. (author)

  8. 76 FR 9577 - Healthcare Infection Control Practices Advisory Committee: Notice of Charter Renewal

    Science.gov (United States)

    2011-02-18

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Healthcare... Federal Advisory Committee Act (Pub. L. 92-463) of October 6, 1972, that the Healthcare Infection Control..., Healthcare Infection Control Practices Advisory Committee, Department of Health and Human Services, 1600...

  9. 78 FR 6328 - Healthcare Infection Control Practices Advisory Committee: Notice of Charter Renewal

    Science.gov (United States)

    2013-01-30

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Healthcare... Federal Advisory Committee Act (Pub. L. 92-463) of October 6, 1972, that the Healthcare Infection Control..., Healthcare Infection Control Practices Advisory Committee, Department of Health and Human Services, 1600...

  10. Protection against Natural Radiation at Home and at Work Exclusion, Practice, Intervention-Theory and Practice

    International Nuclear Information System (INIS)

    Schlesinger, T.; Kock, J.

    2004-01-01

    The issues related to protection against natural radiation at home and at work are addressed in the last fifteen years by various international organizations, professional bodies and national laws and regulations. The ICRP and the IAEA outlined theoretical principles, basic recommendations and some practical instructions for the classification of exposure situations to natural radiation sources into those that are dealt in the framework of practices and interventions and those that are excluded from the framework because they are un-amenable to control. However, in many practical cases, this classification appears to be a complex task, which has to be tackled by the national competent authorities in each country. When trying to convert the principles and guidance outlined by the international bodies into national regulations and practical instructions, we discover that some issues are undecided upon and guidance is lacking relating to sources and practices that were not explicitly addressed. Furthermore, some ambiguities in the principles and guidelines can be detected and difficulties encountered in their implementation. The recommendations and instructions of the ICRP and the IAEA related to natural radiation sources and chronic exposure and their interpretation by the European Commission are reviewed and analyzed. Their implications on the possible ways to handle issues such as the protection against radon at home and at work, the limits to be set on natural radioactive substances in building materials and the radiation risks related to the phosphate and coal ash industries are discussed. Recent decisions of the competent authorities in Israel and Israeli regulations and standardization related to some of these issues are presented. (Author) 12 refs

  11. Randomised controlled trials and changing public health practice

    Directory of Open Access Journals (Sweden)

    Anne Cockcroft

    2017-05-01

    Full Text Available Abstract One reason for doing randomised controlled trials (RCTs is that experiments can be convincing. Early epidemiological experimenters, such as Jenner and the smallpox vaccine and Snow and his famous Broad Street pump handle, already knew the answer they were demonstrating; they used the experiments as knowledge translation devices to convince others. More sophisticated modern experiments include cluster randomised controlled trials (CRCTs for experiments in the public health setting. The knowledge translation value remains: RCTs and CRCTs can potentially stimulate changes of practice among stakeholders. Capitalising on the knowledge translation value of RCTs requires more than the standard reporting of trials. Those who are convinced by a trial and want to act, need to know how the trial relates to their own context, what contributed to success, and what might make it even more effective. Implementation research unpacks the back-story, examining how and why an intervention worked. The Camino Verde trial of community mobilisation for control of dengue reported a significant impact on entomological indices of the Aedes aegypti vector, and on serological dengue virus infection and self-reported dengue cases. This important study should lead to studies of similar interventions in other contexts, and ultimately to changes in dengue control practices. This supplement is the back-story of the trial, providing information to help researchers and planners to make use of the trial findings. Background articles include the full protocol, a systematic review of CRCTs of approaches for Aedes aegypti control, epidemiological and entomological findings from the baseline survey, and how baseline findings were used to set up the intervention. Secondary analyses of the entomological findings examine associations with the use of the larvicide temephos, and the impact of the intervention in different conditions of water supply and seasons. Other articles

  12. National system of notification, authorization and inspection for the control of radiation sources in Ghana

    International Nuclear Information System (INIS)

    Schandorf, C.; Darko, E.O.; Yeboah, J.; Asiamah, S.D.

    2001-01-01

    The Radiation Protection Board (RPB) was established in 1993 in Ghana as the regulatory authority for radiation protection and safety of radiation sources; its functions are prescribed in the 1993 national radiation protection regulation. The report describes how the country's radiation protection and safety infrastructure have been established, including the RPB's organizational structure, with reference in particular to the main activities carried out by both the Regulatory Control Department and the Radiation and Waste Safety Department. It also briefly mentions the existing RPB human resources; the national system of notification, authorization and inspection of radiation sources; the inventory of radiation sources; and the management of disused radiation sources. Finally, the report identifies the two main problem areas regarding the regulatory control of radiation sources in the country. (author)

  13. Autonomous Micro-Air-Vehicle Control Based on Visual Sensing for Odor Source Localization

    Directory of Open Access Journals (Sweden)

    Kenzo Kurotsuchi

    2017-07-01

    Full Text Available In this paper, we propose a novel control method for autonomous-odor-source localization using visual and odor sensing by micro air vehicles (MAVs. Our method is based on biomimetics, which enable highly autonomous localization. Our method does not need any instruction signals, including even global positioning system (GPS signals. An experimenter simply blows a whistle, and the MAV will then start to hover, to seek an odor source, and to keep hovering near the source. The GPS-signal-free control based on visual sense enables indoor/underground use. Moreover, the MAV is light-weight (85 grams and does not cause harm to others even if it accidentally falls. Experiments conducted in the real world were successful in enabling odor source localization using the MAV with a bio-inspired searching method. The distance error of the localization was 63 cm, more accurate than the target distance of 120 cm for individual identification. Our odor source localization is the first step to a proof of concept for a danger warning system. These localization experiments were the first step to a proof of concept for a danger warning system to enable a safer and more secure society.

  14. The Variation Characteristic of Sulfides and VOSc in a Source Water Reservoir and Its Control Using a Water-Lifting Aerator

    Directory of Open Access Journals (Sweden)

    Jian-Chao Shi

    2016-04-01

    Full Text Available Sulfides and volatile organic sulfur compounds (VOSc in water are not only malodorous but also toxic to humans and aquatic organisms. They cause serious deterioration in the ecological environment and pollute drinking water sources. In the present study, a source water reservoir—Zhoucun Reservoir in East China—was selected as the study site. Through a combination of field monitoring and in situ release experiments of sulfides, the characteristics of seasonal variation and distribution of sulfides and VOSc in the reservoir were studied, and the cause of the sulfide pollution was explained. The results show that sulfide pollution was quite severe in August and September 2014 in the Zhoucun Reservoir, with up to 1.59 mg·L−1 of sulfides in the lower layer water. The main source of sulfides is endogenous pollution. VOSc concentration correlates very well with that of sulfides during the summer, with a peak VOSc concentration of 44.37 μg·L−1. An installed water-lifting aeration system was shown to directly oxygenate the lower layer water, as well as mix water from the lower and the upper layers. Finally, the principle and results of controlling sulfides and VOSc in reservoirs using water-lifting aerators are clarified. Information about sulfides and VOSc fluctuation and control gained in this study may be applicable to similar reservoirs, and useful in practical water quality improvement and pollution prevention.

  15. NicoLase-An open-source diode laser combiner, fiber launch, and sequencing controller for fluorescence microscopy.

    Directory of Open Access Journals (Sweden)

    Philip R Nicovich

    Full Text Available Modern fluorescence microscopy requires software-controlled illumination sources with high power across a wide range of wavelengths. Diode lasers meet the power requirements and combining multiple units into a single fiber launch expands their capability across the required spectral range. We present the NicoLase, an open-source diode laser combiner, fiber launch, and software sequence controller for fluorescence microscopy and super-resolution microscopy applications. Two configurations are described, giving four or six output wavelengths and one or two single-mode fiber outputs, with all CAD files, machinist drawings, and controller source code openly available.

  16. BOOK REVIEW OF "ASSESSMENT AND CONTROL OF NONPOINT SOURCE POLLUTION OF AQUATIC ECOSYSTEMS: A PRACTICAL APPROACH"

    Science.gov (United States)

    This book is geared to environmental specialists and planners, heavy on the technical side. It goes beyond tranditional nonpoint source (NPS) approaches which typically only look at stormwater as athe sole NPS pollution driver. There is some overreaching material beyond the conte...

  17. Nurse-physician teamwork in the emergency department: impact on perceptions of job environment, autonomy, and control over practice.

    Science.gov (United States)

    Ajeigbe, David O; McNeese-Smith, Donna; Leach, Linda Searle; Phillips, Linda R

    2013-03-01

    Teamwork is essential to safety. Few studies focus on teamwork between nurses and physicians in emergency departments (EDs). The aim of this study was to examine differences between staff in the interventional group EDs (IGEDs) and control group EDs (CGEDs) on perception of job environment, autonomy, and control over practice. This was a comparative cross-sectional study of the impact of teamwork on perceptions of job environment, autonomy, and control over practice by registered nurses and physicians (MDs) in EDs. Staff in the IGEDs showed significant differences compared with staff who worked in the CGEDs on staff perception of job environment, autonomy, and control over practice. Active teamwork practice was associated with increased perceptions of a positive job environment, autonomy, and control over practice of both nurses and physicians.

  18. From linear to nonlinear control means: a practical progression.

    Science.gov (United States)

    Gao, Zhiqiang

    2002-04-01

    With the rapid advance of digital control hardware, it is time to take the simple but effective proportional-integral-derivative (PID) control technology to the next level of performance and robustness. For this purpose, a nonlinear PID and active disturbance rejection framework are introduced in this paper. It complements the existing theory in that (1) it actively and systematically explores the use of nonlinear control mechanisms for better performance, even for linear plants; (2) it represents a control strategy that is rather independent of mathematical models of the plants, thus achieving inherent robustness and reducing design complexity. Stability analysis, as well as software/hardware test results, are presented. It is evident that the proposed framework lends itself well in seeking innovative solutions to practical problems while maintaining the simplicity and the intuitiveness of the existing technology.

  19. How parental dietary behavior and food parenting practices affect children's dietary behavior. Interacting sources of influence?

    Science.gov (United States)

    Larsen, Junilla K; Hermans, Roel C J; Sleddens, Ester F C; Engels, Rutger C M E; Fisher, Jennifer O; Kremers, Stef P J

    2015-06-01

    Until now, the literatures on the effects of food parenting practices and parents' own dietary behavior on children's dietary behavior have largely been independent from one another. Integrating findings across these areas could provide insight on simultaneous and interacting influences on children's food intake. In this narrative review, we provide a conceptual model that bridges the gap between both literatures and consists of three main hypotheses. First, parental dietary behavior and food parenting practices are important interactive sources of influence on children's dietary behavior and Body Mass Index (BMI). Second, parental influences are importantly mediated by changes in the child's home food environment. Third, parenting context (i.e., parenting styles and differential parental treatment) moderates effects of food parenting practices, whereas child characteristics (i.e., temperament and appetitive traits) mainly moderate effects of the home food environment. Future studies testing (parts of) this conceptual model are needed to inform effective parent-child overweight preventive interventions. Copyright © 2015 Elsevier Ltd. All rights reserved.

  20. Atmospheric heavy metals and Arsenic in China: Situation, sources and control policies

    Science.gov (United States)

    Duan, Jingchun; Tan, Jihua

    2013-08-01

    In recent years, heavy metal pollution accidents were reported frequently in China. The atmospheric heavy metal pollution is drawing all aspects of attention. This paper summarizes the recent research results from our studies and previous studies in recent years in China. The level, temporal variation, seasonal variation and size distribution of the heavy metals of atmospheric Lead(Pb), Vanadium(V), Manganese(Mn), Nickel(Ni), Chromium(Cr), Cadmium(Cd), Copper(Cu), Zinc(Zn) and Arsenic(As) were characterized in China. The emission characteristics and sources of atmospheric heavy metals and As in China were reviewed. Coal burning, iron and steel industry and vehicle emission are important sources in China. Control policies and effects in China were reviewed including emission standards, ambient air quality standards, phase out of leaded gasoline and so on, and further works for atmospheric heavy metals control were suggested. The comprehensive heavy metals pollution control measures and suggestions were put forward based on the summarization of the development and experience of the atmospheric heavy metal pollution control abroad.

  1. [Evaluation of practices for the prevention and control of bloodstream infections in a government hospital].

    Science.gov (United States)

    Jardim, Jaquelline Maria; Lacerda, Rúbia Aparecida; Soares, Naury de Jesus Danzi; Nunes, Bruna Kosar

    2013-02-01

    The aim of this study was to observe clinical procedures in order to evaluate the practices used for the control and prevention of bloodstream infections associated with short-term central venous catheters (BSI-ACVC). The study data came from 5877 assessments distributed among selected practices. The results revealed the following adherence rates among the practices selected: 91.6% for recording the indication and permanence time of the CVC, 51.5% for adhering to the care and maintenance of the dressing at the CVC insertion site and its devices, 10.7% for hand hygiene practices while performing procedures related to the CVC, and 0.0% for the practices related to the insertion of the central venous catheter (CVC). The results demonstrate the need for further elaboration of strategies that ensure sustainable compliance practices for prevention and control BSI-ACVC in the institution being assessed.

  2. Preparation method and quality control of multigamma volume sources with different matrices.

    Science.gov (United States)

    Listkowska, A; Lech, E; Saganowski, P; Tymiński, Z; Dziel, T; Cacko, D; Ziemek, T; Kołakowska, E; Broda, R

    2018-04-01

    The aim of the work was to develop new radioactive standard sources based on epoxy resins. The optimal proportions of the components and the homogeneity of the matrices were determined. The activity of multigamma sources prepared in Marinelli beakers was determined with reference to the National Standard of Radionuclides Activity in Poland. The difference of radionuclides activity values determined using calibrated gamma spectrometer and the activity of standard solutions used are in most cases significantly lower than measurement uncertainty limits. Sources production method and quality control procedure have been developed. Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. Status and design of the Advanced Photon Source control system

    International Nuclear Information System (INIS)

    McDowell, W.; Knott, M.; Lenkszus, F.; Kraimer, M.; Arnold, N.; Daly, R.

    1993-01-01

    This paper presents the current status of the Advanced Photon Source (APS) control system. It will discuss the design decisions which led us to use industrial standards and collaborations with other laboratories to develop the APS control system. The system uses high performance graphic workstations and the X-windows Graphical User Interface (GUI) at the operator interface level. It connects to VME/VXI-based microprocessors at the field level using TCP/IP protocols over high performance networks. This strategy assures the flexibility and expansibility of the control system. A defined interface between the system components will allow the system to evolve with the direct addition of future, improved equipment and new capabilities

  4. Association between Australian-Indian mothers' controlling feeding practices and children's appetite traits.

    Science.gov (United States)

    Jani, Rati; Mallan, Kimberley M; Daniels, Lynne

    2015-01-01

    This cross-sectional study examined the association between controlling feeding practices and children's appetite traits. The secondary aim studied the relationship between controlling feeding practices and two proxy indicators of diet quality. Participants were 203 Australian-Indian mothers with children aged 1-5 years. Controlling feeding practices (pressure to eat, restriction, monitoring) and children's appetite traits (food approach traits: food responsiveness, enjoyment of food, desire to drink, emotional overeating; food avoidance traits: satiety responsiveness, slowness in eating, fussiness and emotional undereating) were measured using self-reported, previously validated scales/questionnaires. Children's daily frequency of consumption of core and non-core foods was estimated using a 49-item list of foods eaten (yes/no) in the previous 24 hours as an indicator of diet quality. Higher pressure to eat was associated with higher scores for satiety responsiveness, slowness in eating, fussiness and lower score for enjoyment of food. Higher restriction was related to higher scores for food responsiveness and emotional overeating. Higher monitoring was inversely associated with fussiness, slowness in eating, food responsiveness and emotional overeating and positively associated with enjoyment of food. Pressure to eat and monitoring were related to lower number of core and non-core foods consumed in the previous 24 hours, respectively. All associations remained significant after adjusting for maternal and child covariates (n = 152 due to missing data). In conclusion, pressure to eat was associated with higher food avoidance traits and lower consumption of core foods. Restrictive feeding practices were associated with higher food approach traits. In contrast, monitoring practices were related to lower food avoidance and food approach traits and lower non-core food consumption. Copyright © 2014 Elsevier Ltd. All rights reserved.

  5. Multimorbidity and blood pressure control in 37 651 hypertensive patients from Danish general practice

    DEFF Research Database (Denmark)

    Paulsen, Maja Skov; Andersen, Morten; Thomsen, Janus L

    2013-01-01

    Patients with hypertension are primarily treated in general practice. However, major studies of patients with hypertension are rarely based on populations from primary care. Knowledge of blood pressure (BP) control rates in patients with diabetes and/or cardiovascular diseases (CVDs), who have...... additional comorbidities, is lacking. We aimed to investigate the association of comorbidities with BP control using a large cohort of hypertensive patients from primary care practices....

  6. Asthma Control and Sputum Eosinophils: A Longitudinal Study in Daily Practice.

    Science.gov (United States)

    Demarche, Sophie F; Schleich, Florence N; Paulus, Virginie A; Henket, Monique A; Van Hees, Thierry J; Louis, Renaud E

    Longitudinal trials have suggested that asthma control may be influenced by fluctuations in eosinophilic inflammation. This association has however never been confirmed in daily practice. To investigate the relationship between asthma control and sputum eosinophils in clinical practice. A retrospective longitudinal study was conducted on 187 patients with asthma with at least 2 successful sputum inductions at our Asthma Clinic. Linear mixed models were used to assess the relationship between asthma control and individual changes in sputum eosinophils. Receiver-operating characteristic curves were constructed to define minimal important differences (MIDs) of sputum eosinophils associated with a change of at least 0.5 in Asthma Control Questionnaire (ACQ) score. Then, a validation cohort of 79 patients with asthma was recruited to reassess this relationship and the accuracy of the MID values. A multivariate analysis showed that asthma control was independently associated with individual fluctuations in sputum eosinophil count (P eosinophilic asthma, we calculated a minimal important decrease of 4.3% in the percentage of sputum eosinophils (area under the curve [AUC], 0.69; P eosinophils and the accuracy of the MIDs of sputum eosinophils were confirmed in the validation cohort. At the individual level, asthma control was associated with fluctuations in sputum eosinophil count over time. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.

  7. Radioactive source security: the cultural challenges

    International Nuclear Information System (INIS)

    Englefield, Chris

    2015-01-01

    Radioactive source security is an essential part of radiation protection. Sources can be abandoned, lost or stolen. If they are stolen, they could be used to cause deliberate harm and the risks are varied and significant. There is a need for a global security protection system and enhanced capability to achieve this. The establishment of radioactive source security requires 'cultural exchanges'. These exchanges include collaboration between: radiation protection specialists and security specialists; the nuclear industry and users of radioactive sources; training providers and regulators/users. This collaboration will facilitate knowledge and experience exchange for the various stakeholder groups, beyond those already provided. This will promote best practice in both physical and information security and heighten security awareness generally. Only if all groups involved are prepared to open their minds to listen to and learn from, each other will a suitable global level of control be achieved. (authors)

  8. A survey of food allergen control practices in the U.S. food industry.

    Science.gov (United States)

    Gendel, Steven M; Khan, Nazleen; Yajnik, Monali

    2013-02-01

    Despite awareness of the importance of food allergy as a public health issue, recalls and adverse reactions linked to undeclared allergens in foods continue to occur with high frequency. To reduce the overall incidence of such problems and to ensure that food-allergic consumers have the information they need to prevent adverse reactions, it is important to understand which allergen control practices are currently used by the food industry. Therefore, the U.S. Food and Drug Administration carried out directed inspections of registered food facilities in 2010 to obtain a broader understanding of industry allergen control practices in the United States. The results of these inspections show that allergen awareness and the use of allergen controls have increased greatly in the last decade, but that small facilities lag in implementing allergen controls.

  9. Two Model-Based Methods for Policy Analyses of Fine Particulate Matter Control in China: Source Apportionment and Source Sensitivity

    Science.gov (United States)

    Li, X.; Zhang, Y.; Zheng, B.; Zhang, Q.; He, K.

    2013-12-01

    Anthropogenic emissions have been controlled in recent years in China to mitigate fine particulate matter (PM2.5) pollution. Recent studies show that sulfate dioxide (SO2)-only control cannot reduce total PM2.5 levels efficiently. Other species such as nitrogen oxide, ammonia, black carbon, and organic carbon may be equally important during particular seasons. Furthermore, each species is emitted from several anthropogenic sectors (e.g., industry, power plant, transportation, residential and agriculture). On the other hand, contribution of one emission sector to PM2.5 represents contributions of all species in this sector. In this work, two model-based methods are used to identify the most influential emission sectors and areas to PM2.5. The first method is the source apportionment (SA) based on the Particulate Source Apportionment Technology (PSAT) available in the Comprehensive Air Quality Model with extensions (CAMx) driven by meteorological predictions of the Weather Research and Forecast (WRF) model. The second method is the source sensitivity (SS) based on an adjoint integration technique (AIT) available in the GEOS-Chem model. The SA method attributes simulated PM2.5 concentrations to each emission group, while the SS method calculates their sensitivity to each emission group, accounting for the non-linear relationship between PM2.5 and its precursors. Despite their differences, the complementary nature of the two methods enables a complete analysis of source-receptor relationships to support emission control policies. Our objectives are to quantify the contributions of each emission group/area to PM2.5 in the receptor areas and to intercompare results from the two methods to gain a comprehensive understanding of the role of emission sources in PM2.5 formation. The results will be compared in terms of the magnitudes and rankings of SS or SA of emitted species and emission groups/areas. GEOS-Chem with AIT is applied over East Asia at a horizontal grid

  10. Control of the safety and security of radiation sources in Argentina

    International Nuclear Information System (INIS)

    Oliveira, A.A.

    2001-01-01

    The report refers to the main elements of the regulatory infrastructure in Argentina, noting as relevant the promulgation in 1997 of the Act 24.804, which established the Nuclear Regulatory Authority (ARN) as an independent agency empowered to establish standards and enforce their application with regard to the possession and use of radiation sources. Important elements of such regulatory infrastructure are described in the report, and in particular those explaining the existing licensing system, the basic radiological safety and security requirements, the enforcement programme, and the key actions considered for the appropriate control of radioactive sources. In this respect, the report emphasizes the importance of the management of disused and orphan sources, and the role of education and training. (author)

  11. General problems associated with the control and safe use of radiation sources (199)

    International Nuclear Information System (INIS)

    Ahmed, J.U.

    1993-01-01

    There are problems at various levels in ensuring safety in the use of radiation sources. A relatively new problem that warrants international action is the smuggling of radioactive material across international borders. An international convention on the control and safe use of radiation sources is essential to provide a universally harmonized mechanism for ensuring safety

  12. Neutron sources: Present practice and future potential

    International Nuclear Information System (INIS)

    Cierjacks, S.; Smith, A.B.

    1988-01-01

    The present capability and future potential of accelerator-based monoenergetic and white neutron sources are outlined in the context of fundamental and applied neutron-nuclear research. The neutron energy range extends from thermal to 500 MeV, and the time domain from steady-state to pico-second pulsed sources. Accelerator technology is summarized, including the production of intense light-ion, heavy-ion and electron beams. Target capabilities are discussed with attention to neutron-producing efficiency and power-handling capabilities. The status of underlying neutron-producing reactions is summarized. The present and future use of neutron sources in: fundamental neutron-nuclear research, nuclear data acquisition, materials damage studies, engineering tests, and biomedical applications are discussed. Emphasis is given to current status, near-term advances well within current technology, and to long-range projections. 90 refs., 4 figs

  13. Multi-sources model and control algorithm of an energy management system for light electric vehicles

    International Nuclear Information System (INIS)

    Hannan, M.A.; Azidin, F.A.; Mohamed, A.

    2012-01-01

    Highlights: ► An energy management system (EMS) is developed for a scooter under normal and heavy power load conditions. ► The battery, FC, SC, EMS, DC machine and vehicle dynamics are modeled and designed for the system. ► State-based logic control algorithms provide an efficient and feasible multi-source EMS for light electric vehicles. ► Vehicle’s speed and power are closely matched with the ECE-47 driving cycle under normal and heavy load conditions. ► Sources of energy changeover occurred at 50% of the battery state of charge level in heavy load conditions. - Abstract: This paper presents the multi-sources energy models and ruled based feedback control algorithm of an energy management system (EMS) for light electric vehicle (LEV), i.e., scooters. The multiple sources of energy, such as a battery, fuel cell (FC) and super-capacitor (SC), EMS and power controller, DC machine and vehicle dynamics are designed and modeled using MATLAB/SIMULINK. The developed control strategies continuously support the EMS of the multiple sources of energy for a scooter under normal and heavy power load conditions. The performance of the proposed system is analyzed and compared with that of the ECE-47 test drive cycle in terms of vehicle speed and load power. The results show that the designed vehicle’s speed and load power closely match those of the ECE-47 test driving cycle under normal and heavy load conditions. This study’s results suggest that the proposed control algorithm provides an efficient and feasible EMS for LEV.

  14. SU-F-T-71: A Practical Method for Evaluation of Electron Virtual Source Position

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Z; Jiang, W; Stuart, B; Leu, S; Feng, Y [East Carolina University, Greenville, North Carolina (United States); Liu, T [Houston Methodist Hospital, Sugar Land, TX (United States)

    2016-06-15

    Purpose: Since electrons are easily scattered, the virtual source position for electrons is expected to locate below the x-ray target of Medical Linacs. However, the effective SSD method yields the electron virtual position above the x-ray target for some applicators for some energy in Siemens Linacs. In this study, we propose to use IC Profiler (Sun Nuclear) for evaluating the electron virtual source position for the standard electron applicators for various electron energies. Methods: The profile measurements for various nominal source-to-detector distances (SDDs) of 100–115 cm were carried out for electron beam energies of 6–18 MeV. Two methods were used: one was to use a 0.125 cc ion chamber (PTW, Type 31010) with buildup mounted in a PTW water tank without water filled; and the other was to use IC Profiler with a buildup to achieve charge particle equilibrium. The full width at half-maximum (FWHM) method was used to determine the field sizes for the measured profiles. Backprojecting (by a straight line) the distance between the 50% points on the beam profiles for the various SDDs, yielded the virtual source position for each applicator. Results: The profiles were obtained and the field sizes were determined by FWHM. The virtual source positions were determined through backprojection of profiles for applicators (5, 10, 15, 20, 25). For instance, they were 96.415 cm (IC Profiler) vs 95.844 cm (scanning ion chamber) for 9 MeV electrons with 10×10 cm applicator and 97.160 cm vs 97.161 cm for 12 MeV electrons with 10×10 cm applicator. The differences in the virtual source positions between IC profiler and scanning ion chamber were within 1.5%. Conclusion: IC Profiler provides a practical method for determining the electron virtual source position and its results are consistent with those obtained by profiles of scanning ion chamber with buildup.

  15. SU-F-T-71: A Practical Method for Evaluation of Electron Virtual Source Position

    International Nuclear Information System (INIS)

    Huang, Z; Jiang, W; Stuart, B; Leu, S; Feng, Y; Liu, T

    2016-01-01

    Purpose: Since electrons are easily scattered, the virtual source position for electrons is expected to locate below the x-ray target of Medical Linacs. However, the effective SSD method yields the electron virtual position above the x-ray target for some applicators for some energy in Siemens Linacs. In this study, we propose to use IC Profiler (Sun Nuclear) for evaluating the electron virtual source position for the standard electron applicators for various electron energies. Methods: The profile measurements for various nominal source-to-detector distances (SDDs) of 100–115 cm were carried out for electron beam energies of 6–18 MeV. Two methods were used: one was to use a 0.125 cc ion chamber (PTW, Type 31010) with buildup mounted in a PTW water tank without water filled; and the other was to use IC Profiler with a buildup to achieve charge particle equilibrium. The full width at half-maximum (FWHM) method was used to determine the field sizes for the measured profiles. Backprojecting (by a straight line) the distance between the 50% points on the beam profiles for the various SDDs, yielded the virtual source position for each applicator. Results: The profiles were obtained and the field sizes were determined by FWHM. The virtual source positions were determined through backprojection of profiles for applicators (5, 10, 15, 20, 25). For instance, they were 96.415 cm (IC Profiler) vs 95.844 cm (scanning ion chamber) for 9 MeV electrons with 10×10 cm applicator and 97.160 cm vs 97.161 cm for 12 MeV electrons with 10×10 cm applicator. The differences in the virtual source positions between IC profiler and scanning ion chamber were within 1.5%. Conclusion: IC Profiler provides a practical method for determining the electron virtual source position and its results are consistent with those obtained by profiles of scanning ion chamber with buildup.

  16. Attacking a practical quantum-key-distribution system with wavelength-dependent beam-splitter and multiwavelength sources

    International Nuclear Information System (INIS)

    Li, Hong-Wei; Wang, Shuang; Huang, Jing-Zheng; Chen, Wei; Yin, Zhen-Qiang; Li, Fang-Yi; Zhou, Zheng; Liu, Dong; Zhang, Yang; Guo, Guang-Can; Han, Zheng-Fu; Bao, Wan-Su

    2011-01-01

    It is well known that the unconditional security of quantum-key distribution (QKD) can be guaranteed by quantum mechanics. However, practical QKD systems have some imperfections, which can be controlled by the eavesdropper to attack the secret key. With current experimental technology, a realistic beam splitter, made by fused biconical technology, has a wavelength-dependent property. Based on this fatal security loophole, we propose a wavelength-dependent attacking protocol, which can be applied to all practical QKD systems with passive state modulation. Moreover, we experimentally attack a practical polarization encoding QKD system to obtain all the secret key information at the cost of only increasing the quantum bit error rate from 1.3 to 1.4%.

  17. Value-based HR practices, i-deals and clinical error control with CSR as a moderator.

    Science.gov (United States)

    Luu, Tuan; Rowley, Chris; Siengthai, Sununta; Thanh Thao, Vo

    2017-05-08

    Purpose Notwithstanding the rising magnitude of system factors in patient safety improvement, "human factors" such as idiosyncratic deals (i-deals) which also contribute to the adjustment of system deficiencies should not be neglected. The purpose of this paper is to investigate the role of value-based HR practices in catalyzing i-deals, which then influence clinical error control. The research further examines the moderating role of corporate social responsibility (CSR) on the effect of value-based HR practices on i-deals. Design/methodology/approach The data were collected from middle-level clinicians from hospitals in the Vietnam context. Findings The research results confirmed the effect chain from value-based HR practices through i-deals to clinical error control with CSR as a moderator. Originality/value The HRM literature is expanded through enlisting i-deals and clinical error control as the outcomes of HR practices.

  18. AHP Expert Programme As A Tool For Unsealed Sources Contamination Control Of The Environment

    International Nuclear Information System (INIS)

    Amin, E.T.; Ibrahim, M.S.; Hussein, A.Z.

    2007-01-01

    Unsealed sources of radionuclides are widely used in hot laboratories of medical centers and hospitals which can be easily dispersed and may be taken undue into the body. The presence of radioactive substances inside the human body generates risk of internal intakes of radionuclides and organ's tissue retention. In order to make control for any contamination occurring from unsealed sources, an AHP programme (PC programme) has been developed so that it includes all data of most unsealed sources used in the hot laboratories of nuclear medicine units at hospitals/medical centers. Sequence of questions are retrieved by the programme in relevance to the place address, uses, activity and half life of the unsealed radioisotopes that may cause contamination. The programme will also give information output about the hospital that use the unsealed source and its location which facilitate emergency planning and contamination control to the environment

  19. Direct Power Control for Three-Phase Two-Level Voltage-Source Rectifiers Based on Extended-State Observation

    DEFF Research Database (Denmark)

    Song, Zhanfeng; Tian, Yanjun; Yan, Zhuo

    2016-01-01

    This paper proposed a direct power control strategy for three-phase two-level voltage-source rectifiers based on extended-state observation. Active and reactive powers are directly regulated in the stationary reference frame. Similar to the family of predictive controllers whose inherent characte......This paper proposed a direct power control strategy for three-phase two-level voltage-source rectifiers based on extended-state observation. Active and reactive powers are directly regulated in the stationary reference frame. Similar to the family of predictive controllers whose inherent...

  20. Improvements in cross-infection control in general dental practice.

    Science.gov (United States)

    Bentley, E M; Sarll, D W

    1995-07-08

    A questionnaire about cross-infection control was sent to all GDPs in five FHSAs in the North Western Region. Replies came from 312 dentists, a response rate of 74%. They worked in 185 practices, a response rate of 85%. Gloves were worn routinely by 86% of dentists and 80% of DSAs. Handpieces were autoclaved between patients in 77% of practices. Much however, remains to be improved. DSAs could be better protected if more ultrasonic cleaners were used, eye protection encouraged and heavy duty gloves were available for cleaning instruments. BDA guidelines were reported as being the most influential factor, though it would appear that the media did persuade many practitioners to use autoclavable handpieces and sterilise them after each use.

  1. Active control of aircraft engine inlet noise using compact sound sources and distributed error sensors

    Science.gov (United States)

    Burdisso, Ricardo (Inventor); Fuller, Chris R. (Inventor); O'Brien, Walter F. (Inventor); Thomas, Russell H. (Inventor); Dungan, Mary E. (Inventor)

    1996-01-01

    An active noise control system using a compact sound source is effective to reduce aircraft engine duct noise. The fan noise from a turbofan engine is controlled using an adaptive filtered-x LMS algorithm. Single multi channel control systems are used to control the fan blade passage frequency (BPF) tone and the BPF tone and the first harmonic of the BPF tone for a plane wave excitation. A multi channel control system is used to control any spinning mode. The multi channel control system to control both fan tones and a high pressure compressor BPF tone simultaneously. In order to make active control of turbofan inlet noise a viable technology, a compact sound source is employed to generate the control field. This control field sound source consists of an array of identical thin, cylindrically curved panels with an inner radius of curvature corresponding to that of the engine inlet. These panels are flush mounted inside the inlet duct and sealed on all edges to prevent leakage around the panel and to minimize the aerodynamic losses created by the addition of the panels. Each panel is driven by one or more piezoelectric force transducers mounted on the surface of the panel. The response of the panel to excitation is maximized when it is driven at its resonance; therefore, the panel is designed such that its fundamental frequency is near the tone to be canceled, typically 2000-4000 Hz.

  2. Overview of the Spallation Neutron Source Linac Low-Level RF Control System

    CERN Document Server

    Champion, Mark; Doolittle, Lawrence; Kasemir, Kay-Uwe; Ma, Hengjie; Piller, Maurice; Ratti, Alessandro

    2005-01-01

    The design and production of the Spallation Neutron Source Linac Low-Level RF control system is complete, and installation will be finished in Spring 2005. The warm linac beam commissioning run in Fall 2004 was the most extensive test to date of the LLRF control system, with fourteen (of an eventual 96) systems operating simultaneously. In this paper we present an overview of the LLRF control system, the experience in designing, building and installing the system, and operational results.

  3. PM10 standards and nontraditional particulate source controls: A summary of the A ampersand WMA/EPA international specialty conference

    International Nuclear Information System (INIS)

    Chow, J.C.; Watson, J.G.; Ono, D.M.; Mathai, C.V.

    1993-01-01

    An international specialty conference, jointly sponsored by the Air ampersand Waste Management Association (A ampersand WMA) and the US Environmental Protection Agency (EPA), entitled open-quotes PM 10 Standards and Nontraditional Particulate Source Controls,close quotes was held in Scottsdale, Arizona, January 12-15, 1992. The conference included 92 presentations in 17 technical sessions. Eight-one peer-reviewed technical papers, two keynote addresses and one panel session summary describing novel applications, measurement processes, modeling techniques and control measures for nontraditional pollution sources are assembled in the Transactions. The technical issues addressed during the conference included: (1) measurement methods and data bases; (2) emissions source characterization; (3) source apportionment of nontraditional sources; (4) fugitive dust characterization and control technologies; (5) vegetative burning characterization and control technologies; (6) sources and controls of secondary aerosol and motor vehicle precursors; and (7) regulatory policies and State Implementation Plan (SIP) development. This paper gives an overview of the technical program. 105 refs., 1 tab

  4. Comparative study of microcontroller controlled four-wire voltage and current source shunt active power filters

    Energy Technology Data Exchange (ETDEWEB)

    Pettersson, S.

    2009-07-01

    During the past two decades, active power filters have increasingly grown their popularity as a viable method for improving electric power quality. The main reasons for this have been the advent of fast self-commutating solid-state devices, the progression of digital technology and the improved sensor technology. Four-wire active power filters provide an efficient solution for improving the quality of supply in grounded three-phase systems or three-phase systems with neutral conductors, which are commonly used for powering residential, office and public buildings. Four-wire active power filters are applicable in compensating current harmonics, reactive power, neutral current and load phase imbalance.This thesis presents a comparative study of microcontroller controlled four-wire voltage and current source shunt active power filters. The study includes two voltage source topologies and a current source topology with two different dc-link energy storage structures, which are compared on the basis of their filtering properties, filtering performance and efficiency. The obtained results are used for determining the suitability of current source technology for four-wire active power filtering and finding the most viable four-wire shunt active power filter topology. One commonly recognized disadvantage of the current source active power filter has always been the bulky dc-link inductor. To reduce the size of the dc-link inductor, an alternative dc-link structure for current source active power filters was introduced in the late 80's. The hybrid energy storage consists of both inductive and capacitive energy storage elements, two diodes and two controllable semiconductor switching devices. Since the capacitive element is used as a main storage unit, the inductance of the dc-link inductor can be considerably reduced. However, the original dc current control method proposed is not able to utilize the full potential of the hybrid energy storage and the inductance

  5. Private Practice Teachers in Public Schools: Reexamining Tensions between Professionalism and Bureaucratic Control.

    Science.gov (United States)

    Goldring, Ellen B.; Ogwa, Rodney

    This paper examines the phenomenon of private-practice teachers in public schools. It helps frame the debates surrounding market-driven reforms that are aimed at freeing schools from bureaucratic control and raises several questions about the potential impact of private-practice teachers. It asks whether market-driven reforms within public schools…

  6. 40 CFR 439.22 - Effluent limitations attainable by the application of the best practicable control technology...

    Science.gov (United States)

    2010-07-01

    ... PHARMACEUTICAL MANUFACTURING POINT SOURCE CATEGORY Extraction Products § 439.22 Effluent limitations attainable... wastes in raw waste loads in fact, nor does it mandate any specific practice, but rather describes the...

  7. 40 CFR 432.12 - Effluent limitations attainable by the application of the best practicable control technology...

    Science.gov (United States)

    2010-07-01

    ... application of the best practicable control technology currently available (BPT). 432.12 Section 432.12... attainable by the application of the best practicable control technology currently available (BPT). Except as...) In the case of process wastewater associated with the slaughtering of animals on-site or the...

  8. 40 CFR 432.42 - Effluent limitations attainable by the application of the best practicable control technology...

    Science.gov (United States)

    2010-07-01

    ... application of the best practicable control technology currently available (BPT). 432.42 Section 432.42... attainable by the application of the best practicable control technology currently available (BPT). Except as...) In the case of process wastewater associated with the slaughtering of animals on-site or the...

  9. 40 CFR 432.32 - Effluent limitations attainable by the application of the best practicable control technology...

    Science.gov (United States)

    2010-07-01

    ... application of the best practicable control technology currently available (BPT). 432.32 Section 432.32... attainable by the application of the best practicable control technology currently available (BPT). Except as...) In the case of process wastewater associated with slaughtering of animals on-site or the processing...

  10. People's knowledge and practice about dengue, its vectors, and control means in Brasilia (DF), Brazil: its relevance with entomological factors.

    Science.gov (United States)

    Dégallier, N; Vilarinhos, P T; de Carvalho, M S; Knox, M B; Caetano, J

    2000-06-01

    In South America, the epidemiology and ecology of dengue fever are strongly associated with human habits because the vector Aedes aegypti is strictly urban. Thus, the evaluation of people's knowledge and practice (PKP) is of great importance to improve integrated control measures. A PKP evaluation has been done in a suburb of Brasilia. Thirty questions were submitted to 130 habitants about income level, education, sources of information, specific knowledge about dengue, vector biology, and control measures applied. Other questions were about the responsibility of dengue control and the opportunity of applying a fine to people who would not cooperate with the control measures. Level of PKP was fairly high, either for housekeepers, workers, or students. The mosquito bite was cited as source of infection by 60.8% of interviewed people but 22.3% had no knowledge about this topic. The most cited symptoms in association with dengue were fever (73.1%), headache (66.2%), and rash (35.4%). Knowledge about mosquito biology and control was also fairly accurate, as demonstrated by 96.9% of answers. Elimination of water containers was the most efficient means according to 73% of people. Such action should be done mainly by the citizen (75.3% of answers). Despite the good PKP, correlations existed only between the PKP about vector biology and presence of potential breeding containers in March, and between the PKP about the disease and potential breeding containers in April. In conclusion, global educational campaigns may have a real impact on the PKP but this did not result in effective control of the mosquito breeding containers by the people.

  11. Security of radioactive sources in radiation facilities

    International Nuclear Information System (INIS)

    2011-03-01

    Safety codes and safety standards are formulated on the basis of internationally accepted safety criteria for design, construction and operation of specific equipment, systems, structures and components of nuclear and radiation facilities. Safety codes establish the objectives and set requirements that shall be fulfilled to provide adequate assurance for safety. Safety guides and guidelines elaborate various requirements and furnish approaches for their implementation. Safety manuals deal with specific topics and contain detailed scientific and technical information on the subject. These documents are prepared by experts in the relevant fields and are extensively reviewed by advisory committees of the Board before they are published. The documents are revised when necessary, in the light of experience and feedback from users as well as new developments in the field. In India, radiation sources are being widely used for societal benefits in industry, medical practices, research, training and agriculture. It has been reported from all over the world that unsecured radioactive sources caused serious radiological accidents involving radiation injuries and fatalities. Particular concern was expressed regarding radioactive sources that have become orphaned (not under regulatory control) or vulnerable (under weak regulatory control and about to be orphaned). There is a concern about safety and security of radioactive sources and hence the need of stringent regulatory control over the handling of the sources and their security. In view of this, this guide is prepared which gives provisions necessary to safeguard radiation installations against theft of radioactive sources and other malevolent acts that may result in radiological consequences. It is, therefore, required that the radiation sources are used safely and managed securely by only authorised personnel. This guide is intended to be used by users of radiation sources in developing the necessary security plan for

  12. [Theoretical and practical assessment of Lille general practice and pharmacy students' knowledge about use of inhaler devices for asthma control].

    Science.gov (United States)

    Veylon, P; Rochoy, M; Gautier, S; Wallaert, B; Berkhout, C

    2018-04-01

    Asthma is a potentially serious chronic respiratory disease impacting patients quality of life. Satisfactory control requires proper use of inhaled devices. This study assesses general medical residents and pharmacy students knowledge about proper use of inhaled asthma devices. We evaluated knowledge of 43 general practice students and 43 pharmacy students in Lille for three inhaler devices (metered-dose inhaler, Turbuhaler ® and Diskus ® ) during individual interviews. Students were assessed on 8 proper use criterias for each device. General practice and pharmacy students are unfamiliar with proper use of inhaler devices. However, pharmacy students get better average scores than general practice students for all devices included in this study: 6.3/8 respected criterias against 5/8 for metered-dose inhaler; 5.3/8 against 3.2/8 for Turbuhaler ® ; and 6/8 against 4.3/8 for Diskus ® . Pharmacy students more frequently perform a demonstration of proper use to patients when a device is first prescribed or when a prescription is renewed; general practice students more frequently ask patients themselves to perform a demonstration of proper use. Introducing trainings workshops for inhaler devices to pharmacy and general practice students appears appropriate in order to promote therapeutic patient education, to increase asthma control and better patients life quality. Copyright © 2018 Elsevier Masson SAS. All rights reserved.

  13. A Practical Risk Assessment Methodology for Safety-Critical Train Control Systems

    Science.gov (United States)

    2009-07-01

    This project proposes a Practical Risk Assessment Methodology (PRAM) for analyzing railroad accident data and assessing the risk and benefit of safety-critical train control systems. This report documents in simple steps the algorithms and data input...

  14. [Pharmaceutical product quality control and good manufacturing practices].

    Science.gov (United States)

    Hiyama, Yukio

    2010-01-01

    This report describes the roles of Good Manufacturing Practices (GMP) in pharmaceutical product quality control. There are three keys to pharmaceutical product quality control. They are specifications, thorough product characterization during development, and adherence to GMP as the ICH Q6A guideline on specifications provides the most important principles in its background section. Impacts of the revised Pharmaceutical Affairs Law (rPAL) which became effective in 2005 on product quality control are discussed. Progress of ICH discussion for Pharmaceutical Development (Q8), Quality Risk Management (Q9) and Pharmaceutical Quality System (Q10) are reviewed. In order to reconstruct GMP guidelines and GMP inspection system in the regulatory agencies under the new paradigm by rPAL and the ICH, a series of Health Science studies were conducted. For GMP guidelines, product GMP guideline, technology transfer guideline, laboratory control guideline and change control system guideline were written. For the GMP inspection system, inspection check list, inspection memo and inspection scenario were proposed also by the Health Science study groups. Because pharmaceutical products and their raw materials are manufactured and distributed internationally, collaborations with other national authorities are highly desired. In order to enhance the international collaborations, consistent establishment of GMP inspection quality system throughout Japan will be essential.

  15. Maternal controlling feeding practices and girls’ inhibitory control interact to predict changes in BMI and eating in the absence of hunger from 5 to 7 y1234

    Science.gov (United States)

    Rollins, Brandi Y; Loken, Eric; Savage, Jennifer S; Birch, Leann L

    2014-01-01

    Background: Mothers use a range of feeding practices to limit children's intake of palatable snacks (eg, keeping snacks out of reach, not bringing snacks into the home), but less is known about the effects of these practices on children's eating and weight outcomes. Objective: The objective was to identify distinct feeding practice profiles and evaluate the interactive effects of these profiles and girls’ temperament (inhibitory control and approach) on girls’ eating behaviors and weight outcomes at 5 and 7 y. Design: Participants included 180 mother-daughter dyads; measures were mothers’ reports of controlling feeding practices and girls’ height and weight, eating in the absence of hunger (EAH) at 5 y, and inhibitory control (a measure of behavioral inhibition) and approach (a measure of appetitive motivation) at 7 y. Results: Latent profile analysis of maternal feeding practices showed 4 feeding profiles based on maternal use of limit-setting practices and keeping snacks out of girls’ physical reach, a restrictive practice: Unlimited Access to Snacks, Sets Limits+Does Not Restrict Snacks, Sets Limits+Restricts High Fat/Sugar Snacks, and Sets Limits+Restricts All Snacks. Girls whose mothers used Sets Limits+Restricts All Snacks had a higher approach and EAH at 5 y. Low inhibitory control girls whose mothers used Sets Limits+Restricts All Snacks or Unlimited Access to Snacks had greater increases in EAH and body mass index (BMI) from 5 to 7 y. Conclusions: Effects of maternal control on girls’ EAH and BMI may differ by the type of practice used (eg, limit-setting or restrictive practices). Girls with low inhibitory control were more susceptible to the negative effects of low and high control. PMID:24284443

  16. Reduction Assessment of Agricultural Non-Point Source Pollutant Loading

    OpenAIRE

    Fu, YiCheng; Zang, Wenbin; Zhang, Jian; Wang, Hongtao; Zhang, Chunling; Shi, Wanli

    2018-01-01

    NPS (Non-point source) pollution has become a key impact element to watershed environment at present. With the development of technology, application of models to control NPS pollution has become a very common practice for resource management and Pollutant reduction control in the watershed scale of China. The SWAT (Soil and Water Assessment Tool) model is a semi-conceptual model, which was put forward to estimate pollutant production & the influences on water quantity-quality under different...

  17. Best Management Practices for sediment control in a Mediterranean agricultural watershed

    Science.gov (United States)

    Abdelwahab, Ossama M. M.; Bingner, Ronald L.; Milillo, Fabio; Gentile, Francesco

    2015-04-01

    Soil erosion can lead to severe destruction of agricultural sustainability that affects not only productivity, but the entire ecosystem in the neighboring areas. Sediments transported together with the associated nutrients and chemicals can significantly impact downstream water bodies. Various conservation and management practices implemented individually or integrated together as a system can be used to reduce the negative impacts on agricultural watersheds from soil erosion. Hydrological models are useful tools for decision makers when selecting the most effective combination of management practices to reduce pollutant loads within a watershed system. The Annualized Agricultural Non-point Source (AnnAGNPS) pollutant loading management model can be used to analyze the effectiveness of diverse management and conservation practices that can control or reduce the impact of soil erosion processes and subsequent sediment loads in agricultural watersheds. A 506 km2 Mediterranean medium-size watershed (Carapelle) located in Apulia, Southern Italy was used as a case study to evaluate the model and best management practices (BMPs) for sediment load control. A monitoring station located at the Ordona bridge has been instrumented to continuously monitor stream flow and suspended sediment loads. The station has been equipped with an ultrasound stage meter and a stage recorder to monitor stream flow. An infrared optic probe was used to measure suspended sediment concentrations (Gentile et al., 2010 ). The model was calibrated and validated in the Carapelle watershed on an event basis (Bisantino et al., 2013), and the validated model was used to evaluate the effectiveness of BMPs on sediment reduction. Various management practices were investigated including evaluating the impact on sediment load of: (1) converting all cropland areas into forest and grass covered conditions; (2) converting the highest eroding cropland areas to forest or grass covered conditions; and (3

  18. Using Statistical Process Control to Drive Improvement in Neonatal Care: A Practical Introduction to Control Charts.

    Science.gov (United States)

    Gupta, Munish; Kaplan, Heather C

    2017-09-01

    Quality improvement (QI) is based on measuring performance over time, and variation in data measured over time must be understood to guide change and make optimal improvements. Common cause variation is natural variation owing to factors inherent to any process; special cause variation is unnatural variation owing to external factors. Statistical process control methods, and particularly control charts, are robust tools for understanding data over time and identifying common and special cause variation. This review provides a practical introduction to the use of control charts in health care QI, with a focus on neonatology. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. National Strategy for Regaining Control over Orphan Sources and Improving Control over Vulnerable Sources (Arabic Edition)

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2011-07-15

    . The standards are also applied by regulatory bodies and operators around the world to enhance safety in nuclear power generation and in nuclear applications in medicine, industry, agriculture and research. Safety is not an end in itself but a prerequisite for the purpose of the protection of people in all States and of the environment - now and in the future. The risks associated with ionizing radiation must be assessed and controlled without unduly limiting the contribution of nuclear energy to equitable and sustainable development. Governments, regulatory bodies and operators everywhere must ensure that nuclear material and radiation sources are used beneficially, safely and ethically. The IAEA safety standards are designed to facilitate this, and I encourage all Member States to make use of them.

  20. Status of the Advanced Photon Source and its accelerator control system

    International Nuclear Information System (INIS)

    McDowell, W.; Knott, M.; Kraimer, K.M.

    1993-01-01

    This paper presents the current status of the Advanced Photon Source (APS), its control system and the Experimental Physics and Industrial Control System (EPICS) tools being used to implement this control system. The status of the physical plant and each of the accelerators as well as detailed descriptions of the software tools used to build the accelerator control system are presented. The control system uses high-performance graphic workstations and the X-windows graphical user interface (GUI) at the operator interface level. It connects to VME/VXI-based microprocessors at the field level using TCP/IP protocols over high-performance networks. This strategy assures the flexibility and expansibility of the control system. A defined interface between the system components will allow the system to evolve with the direct addition of future, improved equipment and new capabilities

  1. 40 CFR 432.22 - Effluent limitations attainable by the application of the best practicable control technology...

    Science.gov (United States)

    2010-07-01

    ... application of the best practicable control technology currently available (BPT). 432.22 Section 432.22... attainable by the application of the best practicable control technology currently available (BPT). Except as... limitations: (1) In the case of process wastewater associated with the slaughtering of animals on-site or the...

  2. Open source software migration: Best practices

    CSIR Research Space (South Africa)

    Molefe, Onkgopotse M

    2010-09-01

    Full Text Available Open source software (OSS) has gained prominence worldwide, largely due to cost savings and security considerations. This has caused a change in the IT sector and has led to the migration of desktops from proprietary to OSS. The problem...

  3. Main Activities to Improve the Control of Radioactive Sources and Maintain an Effective Regulatory Nuclear Systems in Brazil

    International Nuclear Information System (INIS)

    Marechal, M.H.

    2016-01-01

    Since 2006, the Directorate of Nuclear Safety and Security, DRS, of National Nuclear Energy Commission, CNEN, has gone through many improvements. In 2006 CNEN signed the commitment to the recommendations of the Code of Conduct on The Safety and Security of Radioactive Sources and the Guidance on The Import and Export of Radioactive Sources. The DRS is responsible for the licensing and control of nuclear facilities, fuel cycle, waste management and the control of radioactive sources and authorizations of medical and industrial installations. In 2009 the department responsible for the control of radioactive sources and authorizations of medical and industrial installations implemented an “Electronic Management System” in which this System integrates the transport department and waste management department. The Electronic Management System is linked to the register of radioactive sources and facilities and there is an access on line to the Customs, making the control of import and export of radioactive sources robust, efficient and fast. During the period from 2006 until 2015 the most relevant regulations related to the control of radioactive sources and authorizations of medical and industrial installations were reviewed and some were elaborated and issued. These documents were in line with the Categorization of Radioactive Sources and the International Basic Safety Standards, issued in the IAEA Safety Standard Series as General Safety Requirements Part 3 (GSR Part 3). The paper describes all the steps that were adopted in order to implement these systems and the improvements on our Nuclear Regulatory Systems. (author)

  4. Radioactive source security: the cultural challenges.

    Science.gov (United States)

    Englefield, Chris

    2015-04-01

    Radioactive source security is an essential part of radiation protection. Sources can be abandoned, lost or stolen. If they are stolen, they could be used to cause deliberate harm and the risks are varied and significant. There is a need for a global security protection system and enhanced capability to achieve this. The establishment of radioactive source security requires 'cultural exchanges'. These exchanges include collaboration between: radiation protection specialists and security specialists; the nuclear industry and users of radioactive sources; training providers and regulators/users. This collaboration will facilitate knowledge and experience exchange for the various stakeholder groups, beyond those already provided. This will promote best practice in both physical and information security and heighten security awareness generally. Only if all groups involved are prepared to open their minds to listen to and learn from, each other will a suitable global level of control be achieved. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  5. Information Support of Optimal Control of Modes of Electric Systems with Renewable Energy Sources

    Directory of Open Access Journals (Sweden)

    Michalina Gryniewicz-Jaworska

    2017-12-01

    Full Text Available To provide necessary quality of electric energy and reliable supply and reduce environmental contamination as a result of energy units operation, renewable sources of energy (RSE, in particular solar electric stations (SES, wind electric stations (WES and small hydropower stations (SHES are intensively developed. The paper considers the conditions of optimality of renewable sources of energy (RSE functioning in electric systems, controllability of which is limited by the impact of non-stable weather conditions. The influence of control system information support on the efficiency of RSE usage is shown.

  6. 40 CFR 439.52 - Effluent limitations attainable by the application of the best practicable control technology...

    Science.gov (United States)

    2010-07-01

    ... PHARMACEUTICAL MANUFACTURING POINT SOURCE CATEGORY Research § 439.52 Effluent limitations attainable by the... inclusion of such wastes in raw waste loads in fact, nor does it mandate any specific practice, but rather...

  7. Standard Practice for Minimizing Dosimetry Errors in Radiation Hardness Testing of Silicon Electronic Devices Using Co-60 Sources

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This practice covers recommended procedures for the use of dosimeters, such as thermoluminescent dosimeters (TLD's), to determine the absorbed dose in a region of interest within an electronic device irradiated using a Co-60 source. Co-60 sources are commonly used for the absorbed dose testing of silicon electronic devices. Note 1—This absorbed-dose testing is sometimes called “total dose testing” to distinguish it from “dose rate testing.” Note 2—The effects of ionizing radiation on some types of electronic devices may depend on both the absorbed dose and the absorbed dose rate; that is, the effects may be different if the device is irradiated to the same absorbed-dose level at different absorbed-dose rates. Absorbed-dose rate effects are not covered in this practice but should be considered in radiation hardness testing. 1.2 The principal potential error for the measurement of absorbed dose in electronic devices arises from non-equilibrium energy deposition effects in the vicinity o...

  8. 40 CFR 63.2343 - What are my requirements for emission sources not requiring control?

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 12 2010-07-01 2010-07-01 true What are my requirements for emission sources not requiring control? 63.2343 Section 63.2343 Protection of Environment ENVIRONMENTAL PROTECTION... (Non-Gasoline) What This Subpart Covers § 63.2343 What are my requirements for emission sources not...

  9. Quantity and quality assessment of randomized controlled trials on orthodontic practice in PubMed.

    Science.gov (United States)

    Shimada, Tatsuo; Takayama, Hisako; Nakamura, Yoshiki

    2010-07-01

    To find current high-quality evidence for orthodontic practice within a reasonable time, we tested the performance of a PubMed search. PubMed was searched using publication type randomized controlled trial and medical subject heading term "orthodontics" for articles published between 2003 and 2007. The PubMed search results were compared with those from a hand search of four orthodontic journals to determine the sensitivity of PubMed search. We evaluated the precision of the PubMed search result and assessed the quality of individual randomized controlled trials using the Jadad scale. Sensitivity and precision were 97.46% and 58.12%, respectively. In PubMed, of the 277 articles retrieved, 161 (58.12%) were randomized controlled trials on orthodontic practice, and 115 of the 161 articles (71.42%) were published in four orthodontic journals: American Journal of Orthodontics and Dentofacial Orthopedics, The Angle Orthodontist, the European Journal of Orthodontics, and the Journal of Orthodontics. Assessment by the Jadad scale revealed 60 high-quality randomized controlled trials on orthodontic practice, of which 45 (75%) were published in these four journals. PubMed is a highly desirable search engine for evidence-based orthodontic practice. To stay current and get high-quality evidence, it is reasonable to look through four orthodontic journals: American Journal of Orthodontics and Dentofacial Orthopedics, The Angle Orthodontist, the European Journal of Orthodontics, and the Journal of Orthodontics.

  10. Control of radiation sources in Brazil; Controle de fontes de radiacao no Brasil

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Silvia Maria Velasques de; Menezes, Sergio Ferreira; Alves Filho, Aristeu Dacio; Xavier, Ana Maria [Comissao Nacional de Energia Nuclear (CNEN), Rio de Janeiro, RJ (Brazil). Superintendencia de Licenciamento e Controle

    1997-12-31

    The radiological accident occurred in Goiania, in 1987, brought to light several deficiencies in the conduction of the licensing processes of medical, industrial and research facilities that handle radioisotopes as well as int he control of radioactive sources in Brazil. The objective of this article is to describe some of the technical and administrative measures taken to ensure the adoption of appropriate radiological safety standards throughout the country, thus reducing the incidence of radiological accidents. (author) 9 refs., 6 figs., 5 tabs.; e-mail: corad at cnen.gov.br

  11. Radon adsorbed in activated charcoal—a simple and safe radiation source for teaching practical radioactivity in schools and colleges

    Science.gov (United States)

    Al-Azmi, Darwish; Mustapha, Amidu O.; Karunakara, N.

    2012-07-01

    Simple procedures for teaching practical radioactivity are presented in a way that attracts students' attention and does not make them apprehensive about their safety. The radiation source is derived from the natural environment. It is based on the radioactivity of radon, a ubiquitous inert gas, and the adsorptive property of activated charcoal. Radon gas from ambient air in the laboratory was adsorbed into about 70 g of activated charcoal inside metallic canisters. Gamma radiation was subsequently emitted from the canisters, following the radioactive decay of radon and its progenies. The intensities of the emitted gamma-rays were measured at suitable intervals using a NaI gamma-ray detector. The counts obtained were analysed and used to demonstrate the radioactive decay law and determine the half-life of radon. In addition to learning the basic properties of radioactivity the students also get practical experience about the existence of natural sources of radiation in the environment.

  12. Radon adsorbed in activated charcoal- a simple and safe radiation source for teaching practical radioactivity in schools and colleges

    International Nuclear Information System (INIS)

    Al-Azmi, D.S.

    2014-01-01

    Simple procedures for teaching practical radioactivity are presented in a way that attracts students' attention and does not make them apprehensive about their safety. The radiation source is derived from the natural environment. It is based on the radioactivity of radon, an ubiquitous inert gas, and the adsorptive property of activated charcoal. Radon gas from ambient air in the laboratory was adsorbed into about 70 gram of activated charcoal inside metallic canisters. Gamma radiation was subsequently emitted from the canisters, following the radioactive decay of radon and its progenies. The intensities of the emitted gamma-rays were measured at suitable intervals using a NaI gamma-ray detector. The counts obtained were analysed and used to demonstrate the radioactive decay law and determine the half-life of radon. In addition to learning the basic properties of radioactivity, the students also get practical experience about the existence of natural sources of radiation in the environment. (author)

  13. Self-Controlled Practice Enhances Motor Learning in Introverts and Extroverts

    Science.gov (United States)

    Kaefer, Angélica; Chiviacowsky, Suzete; Meira, Cassio de Miranda, Jr.; Tani, Go

    2014-01-01

    Purpose: The purpose of the present study was to investigate the effects of self-controlled feedback on the learning of a sequential-timing motor task in introverts and extroverts. Method: Fifty-six university students were selected by the Eysenck Personality Questionnaire. They practiced a motor task consisting of pressing computer keyboard keys…

  14. Control analysis and experimental verification of a practical dc–dc boost converter

    Directory of Open Access Journals (Sweden)

    Saswati Swapna Dash

    2015-12-01

    Full Text Available This paper presents detailed open loop and closed loop analysis on boost dc–dc converter for both voltage mode control and current mode control. Here the boost dc–dc converter is a practical converter considering all possible parasitic elements like ESR and on state voltage drops. The open loop control, closed loop current mode control and voltage mode control are verified. The comparative study of all control techniques is presented. The PI compensator for closed loop current mode control is designed using these classical techniques like root locus technique and bode diagram. The simulation results are validated with the experimental results of voltage mode control for both open loop and closed loop control.

  15. Non-point Source Pollution Modeling Using Geographic Information System (GIS for Representing Best Management Practices (BMP in the Gorganrood Watershed

    Directory of Open Access Journals (Sweden)

    Z. Pasandidehfard

    2014-09-01

    Full Text Available The most important pollutants that cause water pollution are nitrogen and phosphorus from agricultural runoff called Non-Point Source Pollution (NPS. To solve this problem, management practices known as BMPs or Best Management Practices are applied. One of the common methods for Non-Point Source Pollution prediction is modeling. By modeling, efficiency of many practices can be tested before application. In this study, land use changes were studied from the years 1984 till 2010 that showed an increase in agricultural lands from 516908.52 to 630737.19 ha and expansion of cities from 5237.87 to 15487.59 ha and roads from 9666.07 to 11430.24 ha. Using L-THIA model (from nonpoint source pollution models for both land use categories, the amount of pollutant and the volume of runoff were calculated that showed high growth. Then, the seventh sub-basin was recognized as a critical zone in terms of pollution among the sub-basins. In the end, land use change was considered as a BMP using Multi-Criteria Evaluation (MCE based on which a more suitable land use map was produced. After producing the new land use map, L-THIA model was run again and the result of the model was compared to the actual land use to show the effect of this BMP. Runoff volume decreased from 367.5 to 308.6 M3/ha and nitrogen in runoff was reduced from 3.26 to 1.58 mg/L and water BOD from 3.61 to 2.13 mg/L. Other pollutants also showed high reduction. In the end, land use change is confirmed as an effective BMP for Non-Point Source Pollution reduction.

  16. An amplitude and phase control system for the TFTR rf heating sources

    International Nuclear Information System (INIS)

    Cutsogeorge, G.

    1989-04-01

    Feedback loops that control the amplitude and phase of the rf heating sources on TFTR are described. The method for providing arc protection is also discussed. Block diagrams and Bode plots are included. 6 figs

  17. Control and reception of out of use radioactive sources at the CDTN/CNEN, Minas Gerais, Brazil

    International Nuclear Information System (INIS)

    Reis, Luiz C.A.; Guzella, Marcia F.R.; Seles, Sandro R.N.; Cuccia, Valeria

    2011-01-01

    For reception of the received sources and for accomplish with CNEN regulations and IAEA recommendations, the CDTN have implanted a system for receiving those sources and all the procedures for effective control and recovering of information. The CDTN posses a source deposit, a data bank for the inventory and also a Laboratory for Treatment of Sealed Sources

  18. Astronaut Anna Fisher practices control of the RMS in a trainer

    Science.gov (United States)

    1984-01-01

    Astronaut Anna Lee Fisher, mission specialist for 51-A, practices control of the remote manipulator system (RMS) at a special trainer at JSC. Dr. Fisher is pictured in the manipulator development facility (MDF) of JSC's Shuttle mockup and integration laboratory.

  19. Sources and mitigation of interharmonics in back-to-back controllable drives

    DEFF Research Database (Denmark)

    Soltani, Hamid; Loh, Poh Chiang; Blaabjerg, Frede

    2014-01-01

    for the sources, leading to undistorted grid currents, which are growingly important as more drives are tied to the grid. It is shown that in the case of back-to-back controllable drives it is possible to reduce the input current interharmonic distortion caused by motor current imbalance....

  20. Operational techniques employed for the liquid sodium source term control loops

    International Nuclear Information System (INIS)

    Chulos, L.E.

    1976-01-01

    Four Source Term Control Loops (STCLs) have been designed, constructed, and placed into operation at the Hanford Engineering Development Laboratory (HEDL) as part of the Radioactivity Control Technology program. The data obtained are used to determine the corrosion and deposition of LMFBR materials, including corrosion product radionuclides, in a non-isothermal flowing sodium system. The paper discusses operation of the STCL Facilities and, in particular, the methods used for controlling the oxygen content of the liquid sodium. These methods include cold trapping techniques, hot trapping, seeding the cold traps with sodium oxide, and precipitating the oxygen in the cold trap in a controlled manner. Operational problems encountered with the STCL Facilities and the techniques for correcting these problems are also discussed

  1. Top-Down Control of Visual Alpha Oscillations: Sources of Control Signals and Their Mechanisms of Action

    Science.gov (United States)

    Wang, Chao; Rajagovindan, Rajasimhan; Han, Sahng-Min; Ding, Mingzhou

    2016-01-01

    Alpha oscillations (8–12 Hz) are thought to inversely correlate with cortical excitability. Goal-oriented modulation of alpha has been studied extensively. In visual spatial attention, alpha over the region of visual cortex corresponding to the attended location decreases, signifying increased excitability to facilitate the processing of impending stimuli. In contrast, in retention of verbal working memory, alpha over visual cortex increases, signifying decreased excitability to gate out stimulus input to protect the information held online from sensory interference. According to the prevailing model, this goal-oriented biasing of sensory cortex is effected by top-down control signals from frontal and parietal cortices. The present study tests and substantiates this hypothesis by (a) identifying the signals that mediate the top-down biasing influence, (b) examining whether the cortical areas issuing these signals are task-specific or task-independent, and (c) establishing the possible mechanism of the biasing action. High-density human EEG data were recorded in two experimental paradigms: a trial-by-trial cued visual spatial attention task and a modified Sternberg working memory task. Applying Granger causality to both sensor-level and source-level data we report the following findings. In covert visual spatial attention, the regions exerting top-down control over visual activity are lateralized to the right hemisphere, with the dipoles located at the right frontal eye field (FEF) and the right inferior frontal gyrus (IFG) being the main sources of top-down influences. During retention of verbal working memory, the regions exerting top-down control over visual activity are lateralized to the left hemisphere, with the dipoles located at the left middle frontal gyrus (MFG) being the main source of top-down influences. In both experiments, top-down influences are mediated by alpha oscillations, and the biasing effect is likely achieved via an inhibition

  2. Summary of dynamic analyses of the advanced neutron source reactor inner control rods

    International Nuclear Information System (INIS)

    Hendrich, W.R.

    1995-08-01

    A summary of the structural dynamic analyses that were instrumental in providing design guidance to the Advanced Neutron source (ANS) inner control element system is presented in this report. The structural analyses and the functional constraints that required certain performance parameters were combined to shape and guide the design effort toward a prediction of successful and reliable control and scram operation to be provided by these inner control rods

  3. Multiple Logics as a Source of New Practices and Variations in Employee Recruitment Practices

    DEFF Research Database (Denmark)

    Holm, Anna

    Academic research in recruitment lacks insights into why there are variations in organizations’ recruitment strategies and practices. The contribution of this research is to address this question from the perspective of institutional logic at the organizational level of analysis and thereby go some...... way to filling this gap. The data for the research were collected from a population of organizations in Denmark in 2008-2009, mainly by means of qualitative interviews. Three major institutional logics which guide recruitment practices were identified and are presented in this paper. These logics...... - administration, efficiency and effectiveness – suggest that organizations’ recruitment practices are dominated by diverse goals and different means of achieving them, which can explain the variations in recruitment strategies and practices....

  4. A practical sensitivity analysis method for ranking sources of uncertainty in thermal–hydraulics applications

    Energy Technology Data Exchange (ETDEWEB)

    Pourgol-Mohammad, Mohammad, E-mail: pourgolmohammad@sut.ac.ir [Department of Mechanical Engineering, Sahand University of Technology, Tabriz (Iran, Islamic Republic of); Hoseyni, Seyed Mohsen [Department of Basic Sciences, East Tehran Branch, Islamic Azad University, Tehran (Iran, Islamic Republic of); Hoseyni, Seyed Mojtaba [Building & Housing Research Center, Tehran (Iran, Islamic Republic of); Sepanloo, Kamran [Nuclear Science and Technology Research Institute, Tehran (Iran, Islamic Republic of)

    2016-08-15

    Highlights: • Existing uncertainty ranking methods prove inconsistent for TH applications. • Introduction of a new method for ranking sources of uncertainty in TH codes. • Modified PIRT qualitatively identifies and ranks uncertainty sources more precisely. • The importance of parameters is calculated by a limited number of TH code executions. • Methodology is applied successfully on LOFT-LB1 test facility. - Abstract: In application to thermal–hydraulic calculations by system codes, sensitivity analysis plays an important role for managing the uncertainties of code output and risk analysis. Sensitivity analysis is also used to confirm the results of qualitative Phenomena Identification and Ranking Table (PIRT). Several methodologies have been developed to address uncertainty importance assessment. Generally, uncertainty importance measures, mainly devised for the Probabilistic Risk Assessment (PRA) applications, are not affordable for computationally demanding calculations of the complex thermal–hydraulics (TH) system codes. In other words, for effective quantification of the degree of the contribution of each phenomenon to the total uncertainty of the output, a practical approach is needed by considering high computational burden of TH calculations. This study aims primarily to show the inefficiency of the existing approaches and then introduces a solution to cope with the challenges in this area by modification of variance-based uncertainty importance method. Important parameters are identified by the modified PIRT approach qualitatively then their uncertainty importance is quantified by a local derivative index. The proposed index is attractive from its practicality point of view on TH applications. It is capable of calculating the importance of parameters by a limited number of TH code executions. Application of the proposed methodology is demonstrated on LOFT-LB1 test facility.

  5. A practical sensitivity analysis method for ranking sources of uncertainty in thermal–hydraulics applications

    International Nuclear Information System (INIS)

    Pourgol-Mohammad, Mohammad; Hoseyni, Seyed Mohsen; Hoseyni, Seyed Mojtaba; Sepanloo, Kamran

    2016-01-01

    Highlights: • Existing uncertainty ranking methods prove inconsistent for TH applications. • Introduction of a new method for ranking sources of uncertainty in TH codes. • Modified PIRT qualitatively identifies and ranks uncertainty sources more precisely. • The importance of parameters is calculated by a limited number of TH code executions. • Methodology is applied successfully on LOFT-LB1 test facility. - Abstract: In application to thermal–hydraulic calculations by system codes, sensitivity analysis plays an important role for managing the uncertainties of code output and risk analysis. Sensitivity analysis is also used to confirm the results of qualitative Phenomena Identification and Ranking Table (PIRT). Several methodologies have been developed to address uncertainty importance assessment. Generally, uncertainty importance measures, mainly devised for the Probabilistic Risk Assessment (PRA) applications, are not affordable for computationally demanding calculations of the complex thermal–hydraulics (TH) system codes. In other words, for effective quantification of the degree of the contribution of each phenomenon to the total uncertainty of the output, a practical approach is needed by considering high computational burden of TH calculations. This study aims primarily to show the inefficiency of the existing approaches and then introduces a solution to cope with the challenges in this area by modification of variance-based uncertainty importance method. Important parameters are identified by the modified PIRT approach qualitatively then their uncertainty importance is quantified by a local derivative index. The proposed index is attractive from its practicality point of view on TH applications. It is capable of calculating the importance of parameters by a limited number of TH code executions. Application of the proposed methodology is demonstrated on LOFT-LB1 test facility.

  6. Agriculture and stream water quality: A biological evaluation of erosion control practices

    Science.gov (United States)

    Lenat, David R.

    1984-07-01

    Agricultural runoff affects many streams in North Carolina. However, there is is little information about either its effect on stream biota or any potential mitigation by erosion control practices. In this study, benthic macroinvertebrates were sampled in three different geographic areas of North Carolina, comparing control watersheds with well-managed and poorly managed watersheds. Agricultural streams were characterized by lower taxa richness (especially for intolerant groups) and low stability. These effects were most evident at the poorly managed sites. Sedimentation was the apparent major problem, but some changes at agricultural sites implied water quality problems. The groups most intolerant of agricultural runoff were Ephemeroptera, Plecoptera and Trichoptera. Tolerant species were usually filter-feeders or algal grazers, suggesting a modification of the food web by addition of particulate organic matter and nutrients. This study clearly indicates that agricultural runoff can severely impact stream biota. However, this impact can be greatly mitigated by currently recommended erosion control practices.

  7. Impedance-based Analysis of DC Link Control in Voltage Source Rectifiers

    DEFF Research Database (Denmark)

    Lu, Dapeng; Wang, Xiongfei; Blaabjerg, Frede

    2018-01-01

    This paper analyzes the dynamics influences of the outer dc link control in the voltage source rectifiers based on the impedance model. The ac-dc interactions are firstly presented by means of full order small signal model in dq frame, which shows the input voltage and load condition are the two...

  8. Microfocus x-ray imaging of traceable pointlike {sup 22}Na sources for quality control

    Energy Technology Data Exchange (ETDEWEB)

    Hasegawa, T.; Oda, K.; Sato, Y.; Ito, H.; Masuda, S.; Yamada, T.; Matsumoto, M.; Murayama, H.; Takei, H. [Allied Health Sciences, Kitasato University Kitasato 1-15-1, Minami-ku, Sagamihara-shi, Kanagawa 252-0373 (Japan); Positron Medical Center, Tokyo Metropolitan Institute of Gerontology Sakaecho 35-2, Itabashi-ku, Tokyo 173-0015 (Japan); Advanced Industrial Science and Technology (AIST) Central 2, Umezono 1-1-1, Tsukuba-shi, Ibaraki 305-8568 (Japan); Kanagawa Industrial Technology Center (KITC) Shimoimazumi 705-1, Ebina-shi, Kanagawa 243-0435 (Japan); Japan Radioisotope Association (JRIA) Komagome 2-28-45, Bunkyo-ku, Tokyo 113-8941 (Japan); Molecular Imaging Center, National Institute of Radiological Sciences Anagawa 4-9-1, Inage, Chiba 263-8555 (Japan); Graduate School of Medical Sciences, Kitasato University Kitasato 1-15-1, Minami-ku, Sagamihara-shi, Kanagawa 252-0373 (Japan)

    2012-07-15

    Purpose: The purpose of this study is to propose a microfocus x-ray imaging technique for observing the internal structure of small radioactive sources and evaluating geometrical errors quantitatively, and to apply this technique to traceable pointlike {sup 22}Na sources, which were designed for positron emission tomography calibration, for the purpose of quality control of the pointlike sources. Methods: A microfocus x-ray imaging system with a focus size of 0.001 mm was used to obtain projection x-ray images and x-ray CT images of five pointlike source samples, which were manufactured during 2009-2012. The obtained projection and tomographic images were used to observe the internal structure and evaluate geometrical errors quantitatively. Monte Carlo simulation was used to evaluate the effect of possible geometrical errors on the intensity and uniformity of 0.511 MeV annihilation photon pairs emitted from the sources. Results: Geometrical errors were evaluated with sufficient precision using projection x-ray images. CT images were used for observing the internal structure intuitively. As a result, four of the five examined samples were within the tolerance to maintain the total uncertainty below {+-}0.5%, given the source radioactivity; however, one sample was found to be defective. Conclusions: This quality control procedure is crucial and offers an important basis for using the pointlike {sup 22}Na source as a basic calibration tool. The microfocus x-ray imaging approach is a promising technique for visual and quantitative evaluation of the internal geometry of small radioactive sources.

  9. Public water supply sources - the practical problems

    International Nuclear Information System (INIS)

    Chambers, E.G.W.

    1990-01-01

    A complex system of reservoirs, streams, treatment works and pipe networks is used to provide the public water supply to consumers in Strathclyde. The manner in which a nuclear event would affect the quality of water available from this supply would depend on a wide variety of factors. The extent to which the quality from each source could be maintained or improved if found to be unsatisfactory would depend on the extent of contamination and the particular characteristics of each source. Development of contingency plans will incorporate monitoring of supplies and development of effective communications both internally and externally. (author)

  10. Best practices in tobacco control in the South-East Asia Region.

    Science.gov (United States)

    Zolty, B C; Sinha, P K; Sinha, D N

    2012-01-01

    The tobacco epidemic is an increasing threat to public health with the tobacco burden particularly high in WHO's South-East Asia Region (SEAR). The Region has many obstacles to tobacco control, but despite these challenges, significant progress has been made in many countries. Although much work still needs to be done, SEAR countries have nevertheless implemented strong and often innovative tobacco control measures that can be classified as "best practices," with some setting global precedents. The best practice measures implemented in SEAR include bans on gutka, reducing tobacco imagery in movies, and warning about the dangers of tobacco. In a time of scarce resources, countries in SEAR and elsewhere must ensure that the most effective and cost-efficient measures are implemented. It is hoped that countries can learn from these examples and as appropriate, adapt these measures to their own specific cultural, social and political realities.

  11. Multi-rate control over AWGN channels via analog joint source-channel coding

    KAUST Repository

    Khina, Anatoly; Pettersson, Gustav M.; Kostina, Victoria; Hassibi, Babak

    2017-01-01

    We consider the problem of controlling an unstable plant over an additive white Gaussian noise (AWGN) channel with a transmit power constraint, where the signaling rate of communication is larger than the sampling rate (for generating observations and applying control inputs) of the underlying plant. Such a situation is quite common since sampling is done at a rate that captures the dynamics of the plant and which is often much lower than the rate that can be communicated. This setting offers the opportunity of improving the system performance by employing multiple channel uses to convey a single message (output plant observation or control input). Common ways of doing so are through either repeating the message, or by quantizing it to a number of bits and then transmitting a channel coded version of the bits whose length is commensurate with the number of channel uses per sampled message. We argue that such “separated source and channel coding” can be suboptimal and propose to perform joint source-channel coding. Since the block length is short we obviate the need to go to the digital domain altogether and instead consider analog joint source-channel coding. For the case where the communication signaling rate is twice the sampling rate, we employ the Archimedean bi-spiral-based Shannon-Kotel'nikov analog maps to show significant improvement in stability margins and linear-quadratic Gaussian (LQG) costs over simple schemes that employ repetition.

  12. Multi-rate control over AWGN channels via analog joint source-channel coding

    KAUST Repository

    Khina, Anatoly

    2017-01-05

    We consider the problem of controlling an unstable plant over an additive white Gaussian noise (AWGN) channel with a transmit power constraint, where the signaling rate of communication is larger than the sampling rate (for generating observations and applying control inputs) of the underlying plant. Such a situation is quite common since sampling is done at a rate that captures the dynamics of the plant and which is often much lower than the rate that can be communicated. This setting offers the opportunity of improving the system performance by employing multiple channel uses to convey a single message (output plant observation or control input). Common ways of doing so are through either repeating the message, or by quantizing it to a number of bits and then transmitting a channel coded version of the bits whose length is commensurate with the number of channel uses per sampled message. We argue that such “separated source and channel coding” can be suboptimal and propose to perform joint source-channel coding. Since the block length is short we obviate the need to go to the digital domain altogether and instead consider analog joint source-channel coding. For the case where the communication signaling rate is twice the sampling rate, we employ the Archimedean bi-spiral-based Shannon-Kotel\\'nikov analog maps to show significant improvement in stability margins and linear-quadratic Gaussian (LQG) costs over simple schemes that employ repetition.

  13. Modeling, analysis, and design of stationary reference frame droop controlled parallel three-phase voltage source inverters

    DEFF Research Database (Denmark)

    Vasquez, Juan Carlos; Guerrero, Josep M.; Savaghebi, Mehdi

    2013-01-01

    Power electronics based MicroGrids consist of a number of voltage source inverters (VSIs) operating in parallel. In this paper, the modeling, control design, and stability analysis of parallel connected three-phase VSIs are derived. The proposed voltage and current inner control loops and the mat......Power electronics based MicroGrids consist of a number of voltage source inverters (VSIs) operating in parallel. In this paper, the modeling, control design, and stability analysis of parallel connected three-phase VSIs are derived. The proposed voltage and current inner control loops...... control restores the frequency and amplitude deviations produced by the primary control. Also, a synchronization algorithm is presented in order to connect the MicroGrid to the grid. Experimental results are provided to validate the performance and robustness of the parallel VSI system control...

  14. Academic Librarians’ Conception and Use of Evidence Sources in Practice

    Directory of Open Access Journals (Sweden)

    Denise Koufogiannakis

    2012-12-01

    Full Text Available Objective – The objective of this study was to explore and understand how academic librarians use evidence in their professional decision making. Theresearcher aimed to gain insights on the relevance of the current EBLIP model topractice, and to understand the possible connections between scientific researchand tacit knowledge within the practice of LIS.Methods – A grounded theory methodology was used, following the approach ofCharmaz (2006. Participants were 19 academic librarians in Canada. Data wasgathered via online diaries and semi-structured interviews over a six-month periodin 2011.Results – Two broad types of evidence were identified (hard and soft, and aregenerally used in conjunction with one another. Librarians examine all evidencesources with a critical eye, and try to determine a complete picture before reachinga conclusion. As well, librarians use a variety of proactive and passive approachesto find evidence.Conclusions – These results provide a strong message that no single evidencesource is perfect. Consequently, librarians bring different types of evidencetogether in order to be as informed as possible before making a decision. Using acombination of evidence sources, depending upon the problem, is the wayacademic librarians approach decision making.

  15. A Survey on Open-Source Flight Control Platforms of Unmanned Aerial Vehicle

    DEFF Research Database (Denmark)

    Ebeid, Emad Samuel Malki; Skriver, Martin; Jin, Jie

    2017-01-01

    Recently, Unmanned Aerial Vehicle (UAV), so-called drones, have gotten a lot of attention in academic research and commercial applications due to their simple structure, ease of operations and low-cost hardware components. Flight controller, embedded electronics component, represents the core part...... of the drone. It aims at performing the main operations of the drone (e.g., autonomous control and navigation). There are various types of flight controllers and each of them has its own characteristics and features. This paper presents an extensive survey on the publicly available open-source flight...

  16. Good Manufacturing Practices and Microbial Contamination Sources in Orange Fleshed Sweet Potato Puree Processing Plant in Kenya

    OpenAIRE

    Malavi, Derick Nyabera; Muzhingi, Tawanda; Abong’, George Ooko

    2018-01-01

    Limited information exists on the status of hygiene and probable sources of microbial contamination in Orange Fleshed Sweet Potato (OFSP) puree processing. The current study is aimed at determining the level of compliance to Good Manufacturing Practices (GMPs), hygiene, and microbial quality in OFSP puree processing plant in Kenya. Intensive observation and interviews using a structured GMPs checklist, environmental sampling, and microbial analysis by standard microbiological methods were use...

  17. Crowd Sourcing.

    Science.gov (United States)

    Baum, Neil

    2016-01-01

    The Internet has contributed new words and slang to our daily vernacular. A few terms, such as tweeting, texting, sexting, blogging, and googling, have become common in most vocabularies and in many languages, and are now included in the dictionary. A new buzzword making the rounds in industry is crowd sourcing, which involves outsourcing an activity, task, or problem by sending it to people or groups outside a business or a practice. Crowd sourcing allows doctors and practices to tap the wisdom of many instead of relying only on the few members of their close-knit group. This article defines "crowd sourcing," offers examples, and explains how to get started with this approach that can increase your ability to finish a task or solve problems that you don't have the time or expertise to accomplish.

  18. Analysis of the environmental behavior of farmers for non-point source pollution control and management in a water source protection area in China.

    Science.gov (United States)

    Wang, Yandong; Yang, Jun; Liang, Jiping; Qiang, Yanfang; Fang, Shanqi; Gao, Minxue; Fan, Xiaoyu; Yang, Gaihe; Zhang, Baowen; Feng, Yongzhong

    2018-08-15

    The environmental behavior of farmers plays an important role in exploring the causes of non-point source pollution and taking scientific control and management measures. Based on the theory of planned behavior (TPB), the present study investigated the environmental behavior of farmers in the Water Source Area of the Middle Route of the South-to-North Water Diversion Project in China. Results showed that TPB could explain farmers' environmental behavior (SMC=0.26) and intention (SMC=0.36) well. Furthermore, the farmers' attitude towards behavior (AB), subjective norm (SN), and perceived behavioral control (PBC) positively and significantly influenced their environmental intention; their environmental intention further impacted their behavior. SN was proved to be the main key factor indirectly influencing the farmers' environmental behavior, while PBC had no significant and direct effect. Moreover, environmental knowledge following as a moderator, gender and age was used as control variables to conduct the environmental knowledge on TPB construct moderated mediation analysis. It demonstrated that gender had a significant controlling effect on environmental behavior; that is, males engage in more environmentally friendly behaviors. However, age showed a significant negative controlling effect on pro-environmental intention and an opposite effect on pro-environmental behavior. In addition, environmental knowledge could negatively moderate the relationship between PBC and environmental intention. PBC had a greater impact on the environmental intention of farmers with poor environmental knowledge, compared to those with plenty environmental knowledge. Altogether, the present study could provide a theoretical basis for non-point source pollution control and management. Copyright © 2018 Elsevier B.V. All rights reserved.

  19. Regulatory control of the use of contractors by operating organizations. Peer discussions on regulatory practices

    International Nuclear Information System (INIS)

    2000-09-01

    This report arises from the eighth series of peer discussions on regulatory practices entitled 'Regulatory control of the use of contractors by operating organizations'. Senior regulators from 19 Member States participated in two peer group discussions in March 2000 and May 2000. This report gives an account of the outcomes of these meetings and of practical suggestions put forward by senior regulators. These suggestions do not necessarily reflect the views of the governments of the nominating Member States, the organizations they belong to, or the International Atomic Energy Agency. The objective of this document is to share experience between regulatory bodies and provide practical suggestions for controlling the use of contractors and subcontractors by the operating organizations during all stages, especially operation, of a nuclear power plant, so as to ensure that the quality of work and services delivered is commensurate with the safety importance of the activities and that these are carried out in a manner that will not adversely affect the safe or reliable operation of the facility. These documented practical suggestions and experiences are the result of a series of peer discussions at the IAEA in 2000. It is considered that the manner in which control is exercised, and the various challenges connected to this control, are highly dependent upon the legislative framework, maturity of the nuclear programme, the size of the national nuclear industry and the culture in each country. The report is structured so that it covers the subject matter under the following main headings: Legal Provisions, Regulatory Strategy and Requirements; Regulatory Approaches for Controlling the Use of Contractors; Types of Contracts; Practical Suggestions

  20. FEL polarization control studies on Dalian coherent light source

    International Nuclear Information System (INIS)

    Zhang Tong; Deng Haixiao; Wang Dong; Zhao Zhentang; Zhang Weiqing; Wu Guorong; Dai Dongxu; Yang Xueming

    2013-01-01

    The polarization switch of a free-electron laser (FEL) is of great importance to the user scientific community. In this paper, we investigate the generation of controllable polarization FEL from two well-known approaches for Dalian coherent light source, i.e., crossed planar undulator and elliptical permanent undulator. In order to perform a fair comparative study, a one-dimensional time-dependent FEL code has been developed, in which the imperfection effects of an elliptical permanent undulator are taken into account. Comprehensive simulation results indicate that the residual beam energy chirp and the intrinsic FEL gain may contribute to the degradation of the polarization performance for the crossed planar undulator. The elliptical permanent undulator is not very sensitive to the undulator errors and beam imperfections. Meanwhile, with proper configurations of the main planar undulators and additional elliptical permanent undulator section, circular polarized FEL with pulse energy exceeding 100 μJ could be achieved at Dalian coherent light source. (authors)

  1. Practical experience in the application of quality control in water-reactor fuel fabrication

    International Nuclear Information System (INIS)

    Vollath, D.

    1984-07-01

    Highly industrialized countries have gained vast experience in manufacturing water reactor fuel. Manufacturing is followed by a stringent system of quality assurance and quality control. The Seminar on Practical Experience in the Application of Quality Control in Water-Reactor Fuel Fabrication provided a forum for an exchange of information on methods and systems of quality assurance and quality control for reactor fuel. In addition, many developing countries which have started or intend to set up a nuclear fuel industry are interested in the application of quality assurance and quality control. This meeting has been preceded by two different series of conferences: the IAEA meetings 1976 in Oslo, 1978 in Prague and 1979 in Buenos Aires, and the Karlsruhe meetings on Characterization and Quality Control of Nuclear Fuel held in 1978 and 1981. Quality control and quality assurance has many different facets. Unlike the purely technical aspects, covered by the Karlsruhe conference series, the IAEA meetings always relate to a wider field of topics. They include governmental regulations and codes for practical quality assurance. This volume contains the papers presented at the seminar and a record of the discussions. (orig.)

  2. Telecommuting, Control, and Boundary Management: Correlates of Policy Use and Practice, Job Control, and Work-Family Effectiveness

    Science.gov (United States)

    Kossek, Ellen Ernst; Lautsch, Brenda A.; Eaton, Susan C.

    2006-01-01

    We examine professionals' use of telecommuting, perceptions of psychological job control, and boundary management strategies. We contend that work-family research should distinguish between descriptions of flexibility use (formal telecommuting policy user, amount of telecommuting practiced) and how the individual psychologically experiences…

  3. [Nutrition recommendations for children who practice sports].

    Science.gov (United States)

    Sánchez-Valverde Visus, F; Moráis López, A; Ibáñez, J; Dalmau Serra, J

    2014-08-01

    Several health benefits have been attributed to sports practice, and an adequate nutrition status helps to maintain an optimal performance. Children most frequently practice non-competitive and non-endurance activities in a school setting. The dietary intake of children who practice sports should be similar to the general population, properly meeting their energy and nutrient requirements. During the activity performance, correct hydration should be aimed for, with water appearing to be an adequate source in most cases. General calorie and micronutrient supplementation should not be commonly recommended in children. Paediatricians must control nutritional status and dietary habits of children who practice sports, especially in those cases when weight-loss is aimed for, as well as take into account the psychological implications of competitive sports practice. Copyright © 2013 Asociación Española de Pediatría. Published by Elsevier Espana. All rights reserved.

  4. Low-resolution continuum source simultaneous multi-element electrothermal atomic absorption spectrometry: steps into practice

    International Nuclear Information System (INIS)

    Katskov, Dmitri

    2015-01-01

    The theory and practical problems of continuum source simultaneous multi-element electrothermal atomic absorption spectrometry (SMET AAS) are discussed by the example of direct analysis of underground water. The experimental methodology is based on pulse vaporization of the sample in a fast heated graphite tube and measurement of transient absorption of continuum spectrum radiation from D 2 and Xe lamps within 200–400 nm wavelengths range with a low resolution spectral instrument and linear charge-coupled device. The setup permits the acquisition of 200 spectra during 1 s atomization pulse. Respective data matrix absorbance vs wavelength/time is employed for the quantification of elements in the sample. The calculation algorithm developed includes broad band and continuum background correction, linearization of function absorbance vs. concentration of atomic vapor and integration of thus modified absorbance at the resonance lines of the elements to be determined. Practical application shows that the method can be employed for the direct simultaneous determination of about 20 elements above microgram per liter level within 3–5 orders of the magnitude concentration range. The investigated sources of measurement errors are mainly associated with the atomization and vapor transportation problems, which are aggravated for the simultaneous release of major and minor sample constituents. Respective corrections concerning the selection of analytical lines, optimal sampling volume, matrix modification and cleaning of the atomizer have been introduced in the SMET AAS analytical technology. Under the optimized experimental conditions the calibration curves in Log-Log coordinates for all the investigated analytes in the single or multi-element reference solutions are approximated by the first order equations. The use of these equations as permanent characteristics of the setup enables instant quantification of Al, Ca, Co, Cr, Cu, Fe, Mg, Mn and Ni in the underground water

  5. Low-resolution continuum source simultaneous multi-element electrothermal atomic absorption spectrometry: steps into practice

    Energy Technology Data Exchange (ETDEWEB)

    Katskov, Dmitri, E-mail: katskovda@tut.ac.za

    2015-03-01

    The theory and practical problems of continuum source simultaneous multi-element electrothermal atomic absorption spectrometry (SMET AAS) are discussed by the example of direct analysis of underground water. The experimental methodology is based on pulse vaporization of the sample in a fast heated graphite tube and measurement of transient absorption of continuum spectrum radiation from D{sub 2} and Xe lamps within 200–400 nm wavelengths range with a low resolution spectral instrument and linear charge-coupled device. The setup permits the acquisition of 200 spectra during 1 s atomization pulse. Respective data matrix absorbance vs wavelength/time is employed for the quantification of elements in the sample. The calculation algorithm developed includes broad band and continuum background correction, linearization of function absorbance vs. concentration of atomic vapor and integration of thus modified absorbance at the resonance lines of the elements to be determined. Practical application shows that the method can be employed for the direct simultaneous determination of about 20 elements above microgram per liter level within 3–5 orders of the magnitude concentration range. The investigated sources of measurement errors are mainly associated with the atomization and vapor transportation problems, which are aggravated for the simultaneous release of major and minor sample constituents. Respective corrections concerning the selection of analytical lines, optimal sampling volume, matrix modification and cleaning of the atomizer have been introduced in the SMET AAS analytical technology. Under the optimized experimental conditions the calibration curves in Log-Log coordinates for all the investigated analytes in the single or multi-element reference solutions are approximated by the first order equations. The use of these equations as permanent characteristics of the setup enables instant quantification of Al, Ca, Co, Cr, Cu, Fe, Mg, Mn and Ni in the underground

  6. Knowledge, attitude and practices about hepatitis B and Infection Control Measures among dental students in Patiala

    Directory of Open Access Journals (Sweden)

    Vishal Malhotra

    2017-01-01

    Full Text Available Background: Hepatitis B is highly infectious, but preventable diseases and dentists are at increased risk of exposure to saliva and blood of patients during their clinical practice, and so it is of utmost importance that they follow standard guidelines for infection control. Aims: To assess knowledge, attitude, and practices regarding infection control measures among dental students of Government Dental College in Punjab. Materials and Methods: A cross-sectional survey using a self-administered pretested questionnaire to dental students and responses were statistically analyzed. The analysis of variance was used to compare means of knowledge, attitude, and practice scores between four groups of study subjects and P < 0.05 is considered statistically significant. Results: Although the students have sufficient knowledge regarding hepatitis B, still there are gaps in putting their knowledge into practice. Third and final year students have significantly less mean knowledge and practice scores compared to interns and postgraduate students. The majority of students have a positive attitude and were willing to perform any procedure on hepatitis B-infected patients. Conclusions: Dental students have adequate knowledge and good attitude but still there are some misconceptions. There is poor implementation of standard infection control measures in their practice. Rigorous training programs on preventive practices and regular workshops must be organized on an annual basis in dental colleges. Moreover, hepatitis B vaccination must be made mandatory for students before they start their clinical practice.

  7. Quieting: A Practical Guide to Noise Control. NBS Handbook 119.

    Science.gov (United States)

    Berendt, Raymond D.; And Others

    This guide describes the ways in which sounds are generated, travel, and affect the listener's hearing and well-being. Recommendations are given for controlling noise at the source and along its path of travel, and for protecting the listener. Remedies are given for noise commonly encountered in homes, work environments, schools, while traveling,…

  8. Self-care practices of Malaysian adults with diabetes and sub-optimal glycaemic control.

    Science.gov (United States)

    Tan, Ming Yeong; Magarey, Judy

    2008-08-01

    To investigate the self-care practices of Malaysian adults with diabetes and sub-optimal glycaemic control. Using a one-to-one interviewing approach, data were collected from 126 diabetic adults from four settings. A 75-item questionnaire was used to assess diabetes-related knowledge and self-care practices regarding, diet, medication, physical activity and self-monitoring of blood glucose (SMBG). Most subjects had received advice on the importance of self-care in the management of their diabetes and recognised its importance. Sixty-seven subjects (53%) scored below 50% in their diabetes-related knowledge. Subjects who consumed more meals per day (80%), or who did not include their regular sweetened food intakes in their daily meal plan (80%), or who were inactive in daily life (54%), had higher mean fasting blood glucose levels (p=0.04). Subjects with medication non-adherence (46%) also tended to have higher fasting blood glucose levels. Only 15% of the subjects practiced SMBG. Predictors of knowledge deficit and poor self-care were low level of education (p = <0.01), older subjects (p=0.04) and Type 2 diabetes subjects on oral anti-hyperglycaemic medication (p = <0.01). There were diabetes-related knowledge deficits and inadequate self-care practices among the majority of diabetic patients with sub-optimal glycaemic control. This study should contribute to the development of effective education strategies to promote health for adults with sub-optimal diabetes control.

  9. PM10 standards and nontraditional particulate source controls: Research perspective

    International Nuclear Information System (INIS)

    Watson, J.G.

    1992-01-01

    Knowledge of how to measure suspended particles, what their concentrations are, what they are composed of, and where they come from has increased substantially since 1975. At that time, much of the pioneering work in these areas was just being conducted and published. Size-classified measurements, low-level elemental analysis, inorganic ion analysis, and carbon determinations for aerosol samples were novel research developments. Receptor modeling was not considered to be a scientific discipline, let alone a useful tool for source apportionment. Presentations at earlier conferences went to great lengths to document and justify methodologies which are taken for granted at this conference. This paper goes on to discuss research findings in control of wood smoke, fugitive dusts, motor vehicle exhausts, and secondary aerosols. Research results in source apportionment are also discussed

  10. Sources for charged particles; Les sources de particules chargees

    Energy Technology Data Exchange (ETDEWEB)

    Arianer, J.

    1997-09-01

    This document is a basic course on charged particle sources for post-graduate students and thematic schools on large facilities and accelerator physics. A simple but precise description of the creation and the emission of charged particles is presented. This course relies on every year upgraded reference documents. Following relevant topics are considered: electronic emission processes, technological and practical considerations on electron guns, positron sources, production of neutral atoms, ionization, plasma and discharge, different types of positive and negative ion sources, polarized particle sources, materials for the construction of ion sources, low energy beam production and transport. (N.T.).

  11. Radon Adsorbed in Activated Charcoal--A Simple and Safe Radiation Source for Teaching Practical Radioactivity in Schools and Colleges

    Science.gov (United States)

    Al-Azmi, Darwish; Mustapha, Amidu O.; Karunakara, N.

    2012-01-01

    Simple procedures for teaching practical radioactivity are presented in a way that attracts students' attention and does not make them apprehensive about their safety. The radiation source is derived from the natural environment. It is based on the radioactivity of radon, a ubiquitous inert gas, and the adsorptive property of activated charcoal.…

  12. Charging for waste motivates generators to optimize waste control at the source

    International Nuclear Information System (INIS)

    Berry, J.B.; Homan, F.J.

    1988-01-01

    The Department of Energy (DOE) has recognized the need for waste management that incorporates improved waste-handling techniques and more stringent regulatory requirements to prevent future liabilities such as Superfund sites. DOE-Oak Ridge Operations (DOE-ORO) has recognized that an effective waste management program focuses on control at the source and that the burden for responsible waste management can be placed on generators by charging for waste management costs. The principle of including the waste management costs in the total cost of the product, even when the product is research and development, is being implemented at Oak Ridge National Laboratory (ORNL). Charging waste management costs to generators creates an incentive to optimize processes so that less waste is produced, and it provides a basis for determining the cost effectiveness of capital improvements so that the mature phase of waste management can be attained. Improving waste management practices requires a long-range commitment and consistent administration. Making this commitment and providing adequate funding for proper waste disposal are most cost-effective measures than the alternative of paying for remedial actions after improper disposal. This paper summarizes a plan to charge waste generators, the administrative structure of the plan, a comparison between the rate structure and changes in waste disposal operations, and issues that have surfaced as the plan is implemented

  13. Trends in use of non-medical radiation sources in Slovenia

    International Nuclear Information System (INIS)

    Giacomelli, M.; Cesarek, J.; Osojnik, I.

    2007-01-01

    Slovenian Nuclear Safety Administration is the regulatory authority competent also for administrative control in the fields of radiation practices and use of radiation sources in industry and research, with exception in medicine and veterinary medicine. Prior to the adoption of the Act on Protection against Ionizing Radiation and Nuclear Safety the responsible authority was the Health Inspectorate of Republic of Slovenia. The article presents an overview of the use of radiation sources in Slovenia, in industry, research and education. Analysis of the data from abovementioned regulators shall examine trends in use in recent years as number of sources and organizations, and according to the type of their intended use. (author)

  14. Generic inertia emulation controller for multi-terminal voltage-source-converter high voltage direct current systems

    DEFF Research Database (Denmark)

    Zhu, Jiebei; Guerrero, Josep M.; Hung, William

    2014-01-01

    A generic Inertia Emulation Controller (INEC) scheme for Multi-Terminal Voltage-Source-Converter based HVDC (VSC-MTDC) systems is proposed and presented in this paper. The proposed INEC can be incorporated in any Grid-side Voltage-Source-Converter (GVSC) station, allowing the MTDC terminal...

  15. Simplified sleep restriction for insomnia in general practice: a randomised controlled trial.

    Science.gov (United States)

    Falloon, Karen; Elley, C Raina; Fernando, Antonio; Lee, Arier C; Arroll, Bruce

    2015-08-01

    Insomnia is common in primary care. Cognitive behavioural therapy for insomnia (CBT-I) is effective but requires more time than is available in the general practice consultation. Sleep restriction is one behavioural component of CBT-I. To assess whether simplified sleep restriction (SSR) can be effective in improving sleep in primary insomnia. Randomised controlled trial of patients in urban general practice settings in Auckland, New Zealand. Adults with persistent primary insomnia and no mental health or significant comorbidity were eligible. Intervention patients received SSR instructions and sleep hygiene advice. Control patients received sleep hygiene advice alone. Primary outcomes included change in sleep quality at 6 months measured by the Pittsburgh Sleep Quality Index (PSQI), Insomnia Severity Index (ISI), and sleep efficiency (SE%). The proportion of participants reaching a predefined 'insomnia remission' treatment response was calculated. Ninety-seven patients were randomised and 94 (97%) completed the study. At 6-month follow-up, SSR participants had improved PSQI scores (6.2 versus 8.4, Pinsomnia, the adjusted odds ratio for insomnia remission was 2.7 (95% CI = 1.1 to 6.5). There were no significant differences in other outcomes or adverse effects. SSR is an effective brief intervention in adults with primary insomnia and no comorbidities, suitable for use in general practice. © British Journal of General Practice 2015.

  16. Active and reactive power control of a current-source PWM-rectifier using space vectors

    Energy Technology Data Exchange (ETDEWEB)

    Salo, M.; Tuusa, H. [Tampere University of Technology (Finland). Department of Electrical Engineering, Power Electronics

    1997-12-31

    In this paper the current-source PWM-rectifier with active and reactive power control is presented. The control system is realized using space vector methods. Also, compensation of the reactive power drawn by the line filter is discussed. Some simulation results are shown. (orig.) 8 refs.

  17. Worm Control in Livestock: Bringing Science to the Field.

    Science.gov (United States)

    Kenyon, Fiona; Hutchings, Fiona; Morgan-Davies, Claire; van Dijk, Jan; Bartley, Dave J

    2017-09-01

    Parasitic roundworm infections are ubiquitous in grazing livestock. Chemical control through the frequent 'blanket' administration of anthelmintics (wormers) has been, and remains, the cornerstone in controlling these infections, but this practice is unsustainable. Alternative strategies are available but, even with the plethora of best practice advice available, have yet to be integrated into routine farming practice. This is probably due to a range of factors, including contradictory advice from different sources, changes to advice following increased scientific understanding, and top-down knowledge exchange patterns. In this article, we discuss the worm control options available, the translation of new best practice advice from science bench to field, and ideas for future work and directions. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. Proposed American National Standard ANS 8.22: Nuclear criticality safety based on limiting and controlling moderators

    International Nuclear Information System (INIS)

    Bullington, J.S.

    1996-01-01

    This proposed standard features guidance for dealing with the combination of fissile material and moderators in moderator control areas. The main points include nuclear criticality safety practices, encompassing administrative practices and process evaluations, and engineering practices, encompassing moderator control area barriers, equipment and containers, penetrations, fire prevention and suppression, and active engineered controls. Four appendixes follow the standard; the subject of these appendixes are typical moderating materials, potential sources of moderators, moderator control measurements, and engineered barriers to control moderators

  19. [Infection control management and practice in home care - analysis of structure quality].

    Science.gov (United States)

    Spegel, H; Höller, C; Randzio, O; Liebl, B; Herr, C

    2013-02-01

    Surveillance of infection control management and practices in home care is an important task of the public health service. While infection control aspects in residential homes for the aged and nursing are increasingly being discussed this subject has been poorly recognised in home care. The aim of this study was to identify problems in hygiene regarding the transmission of infectious diseases as well as quality assessment in home care. Based on the results of this study implications for infection control in home care facilities for public health services should be developed. Statistical analyses were performed on the primary quality assessment data of home care facilities collected by the medical service of health insurances via computer-assisted personal interviews between March 2006 and March 2009. Structure quality in 194 home care facilities was analysed as well as human resources and organisational conditions. Analyses were also done in the context of the clients' risk factor load. All analyses were performed by stratifying for the size of the home care services. To assess how the involved characteristics vary according to the size of the home care services chi-square tests and non-parametric tests were calculated. About 80% of the assessed home care services disposed of an infection control management plan. Compared to larger services smaller home care services, especially services with less than 10 clients had a poor structure in infection control management and practice. They also carried a higher load of risk factors in clients. The larger services had significantly less human resources. Surveillance of infection control management and practices by the public health services should focus on the structure of the smaller home care services. At the same time smaller home care services should be supported by offering training for the staff or counselling regarding hygiene-related aspects. Furthermore, the outcome quality of the larger home care services with

  20. Source water assessment and nonpoint sources of acutely toxic contaminants: A review of research related to survival and transport of Cryptosporidium parvum

    Science.gov (United States)

    Walker, Mark J.; Montemagno, Carlo D.; Jenkins, Michael B.

    1998-12-01

    Amendments to the Safe Drinking Water Act (PL-930123) in 1996 required that public water supply managers identify potential sources of contamination within contributing areas. Nonpoint sources of acutely toxic microbial contaminants, such as Cryptosporidium parvum, challenge current approaches to source identification and management as a first step toward developing management plans for public water supply protection. Little may be known about survival and transport in the field environment, prescribed practices may not be designed to manage such substances, and infective stages may be present in vast numbers and may resist water treatment and disinfection processes. This review summarizes research related to survival and transport of C. parvum oocysts, as an example of an acutely toxic contaminant with nonpoint sources in animal agriculture. It discusses ∥1) significance of infected domesticated animals as potential sources of C. parvum, (2) laboratory and field studies of survival and transport, and (3) approaches to source control in the context of public health protection.

  1. The scope and control of attention: Sources of variance in working memory capacity.

    Science.gov (United States)

    Chow, Michael; Conway, Andrew R A

    2015-04-01

    Working memory capacity is a strong positive predictor of many cognitive abilities, across various domains. The pattern of positive correlations across domains has been interpreted as evidence for a unitary source of inter-individual differences in behavior. However, recent work suggests that there are multiple sources of variance contributing to working memory capacity. The current study (N = 71) investigates individual differences in the scope and control of attention, in addition to the number and resolution of items maintained in working memory. Latent variable analyses indicate that the scope and control of attention reflect independent sources of variance and each account for unique variance in general intelligence. Also, estimates of the number of items maintained in working memory are consistent across tasks and related to general intelligence whereas estimates of resolution are task-dependent and not predictive of intelligence. These results provide insight into the structure of working memory, as well as intelligence, and raise new questions about the distinction between number and resolution in visual short-term memory.

  2. Passivity-Based Control applied to DC hybrid power source using fuel cell and supercapacitors

    Energy Technology Data Exchange (ETDEWEB)

    Ayad, M.Y.; Wack, M.; Laghrouche, S. [SeT, UTBM, Belfort (cedex) 90010 (France); Becherif, M. [SeT, UTBM, Belfort (cedex) 90010 (France); FC-Lab, UTBM, Belfort (cedex) 90010 (France); Henni, A. [Alstom Power System, Energy Management Business, Alstom (France); Aboubou, A. [LMSE Laboratory, Biskra University, 07000 (Algeria)

    2010-07-15

    Nowadays, energy management becomes an absolute necessity. To reduce systems consumption, the idea is to recover energy when it is possible and to reuse it when the system is in need. Energy can be saved in peak power unit (electric double layer capacitors called supercapacitors). Those latter can absorb or supply power peaks. This paper deals with the conception of hybrid power sources using fuel cell as main source, a DC link and supercapacitors as transient power source. The whole system is modeled in state space equations. The energy management is reached using Passivity-Based Control (PBC). PBC is a very powerful nonlinear technique dealing with important system information like the system's total energy. Stability proof and simulation results are given. In this proposed control laws only few measurement are needed (two or three depending on the presented solutions one or two). (author)

  3. [Ethical issues linked to the professional practice of nurses in a hospital infection control committee].

    Science.gov (United States)

    Alves, Débora Cristina Ignácio; Evora, Yolanda Dora Martinez

    2002-01-01

    This qualitative work was developed according to Bardin's method of content analysis. It aimed at finding out the perceptions of nurses that are members of a Hospital Infection Control Commission about ethical issues that are inherent to their professional practice as well as understanding the clinical nurses opinion regarding the professional practice of the nurses that are members of the Hospital Infection Control Commission, considering the ethical aspects. In order to achieve an ethical, efficient and effective professional practice, there is a need for governmental changes and professional recognition through autonomy, respect and exclusivity in the Service of Hospital Infection Control, as well as improvements regarding information, the care provided to the patient and professional secret. The predominance of bureaucratic activities and team work were mentioned by the clinical nurses as differentiating factors of the activities performed by nurses that are members of the Commission.

  4. Decentralized and Real-Time Power Dispatch Control for an Islanded Microgrid Supported by Distributed Power Sources

    Directory of Open Access Journals (Sweden)

    Changsun Ahn

    2013-12-01

    Full Text Available Microgrids can deploy traditional and/or renewable power sources to support remote sites. Utilizing renewable power sources requires more complicated control strategies to achieve acceptable power quality and maintain grid stability. In this research, we assume that the grid stability problem is already solved. As a next step, we focus on how the power can be dispatched from multiple power sources for improved grid efficiency. Isolated microgrids frequently require reconfigurations because of the grid expansion or component failures. Therefore, the control strategies ideally should be implemented in a plug-and-play fashion. Moreover, these strategies ideally require no pre-knowledge of the grid structure, and as little communication with neighboring power sources as possible. The control objective is to minimize a cost function that can be adjusted to reflect the desire to minimize energy cost and/or losses. An algorithm is designed to satisfy a derived necessary condition of function optimality. Such conditions are obtained by formulating Lagrange functions. An equivalent grid model approximates the grid structure which was later confirmed to represent the grid behavior adequately. For decentralized operations, we execute the distributed control sequentially using a simple token communication protocol. The performance of the combined system identification-Lagrange function minimization algorithm is demonstrated through simulations.

  5. Regulation for radiation protection in applications of radiation sources

    International Nuclear Information System (INIS)

    Sonawane, Avinash U.

    2016-01-01

    Applications of ionising radiation in multifarious field are increasing in the country for the societal benefits. The national regulatory body ensures safety and security of radiation sources by enforcing provisions in the national law and other relevant rules issued under the principle law. In addition, the enforcement of detailed requirements contained in practice specific safety codes and standard and issuance of safety directives brings effectiveness in ensuring safe handling and secure management of radiation sources. The regulatory requirements for control over radiation sources throughout their life-cycle have evolved over the years from experience gained. Nevertheless, some of the regulatory activities which require special attention have been identified such as the development of regulation to deal with advance emerging radiation technology in applications of radiation in medicine and industry; sustaining continuity in ensuring human resource development programme; inspections of category 3 and 4 disused sources and their safe disposal; measures for controlling transboundary movement of radiation sources. The regulatory measures have been contemplated and are being enforced to deal with the above issues in an effective manner. The complete involvement of the management of radiation facilities, radiation workers and their commitment in establishing and maintaining safety and security culture is essential to handle the radiation sources safely and efficiently at all times

  6. Control of emissions from stationary combustion sources: Pollutant detection and behavior in the atmosphere

    International Nuclear Information System (INIS)

    Licht, W.; Engel, A.J.; Slater, S.M.

    1979-01-01

    Stationary combustion resources continue to be significant sources of NOx and SOx pollutants in the ambient atmosphere. This volume considers four problem areas: (1) control of emissions from stationary combustion sources, particularly SOx and NOx (2) pollutant behavior in the atmosphere (3) advances in air pollution analysis and (4) air quality management. Topics of interest include carbon slurries for sulfur dioxide abatement, mass transfer in the Kellogg-Weir air quality control system, oxidation/inhibition of sulfite ion in aqueous solution, some micrometeorological methods of measuring dry deposition rates, Spanish moss as an indicator of airborne metal contamination, and air quality impacts from future electric power generation in Texas

  7. Spark-protected ion-source control and monitoring system at 1.5 MV

    International Nuclear Information System (INIS)

    Bogaty, J.M.; Zolecki, R.

    1981-01-01

    The Heavy Ion Fusion Program at Argonne National Laboratory utilizes a 1.5-MV Xe ion preaccelerator. Reliable beam transport requires accurate measurements and precise control of various ion-source parameters. This paper discusses the use of a multiplexed fiberoptic data-transmission system and low-cost digital stepper motors for control functions. Techniques are discussed which allow TTL and CMOS semiconductor curcuits to survive the destructive sparks which can occur in the 1.5-MV preaccelerator

  8. The relationship between controlling feeding practices and boys' and girls' eating in the absence of hunger.

    Science.gov (United States)

    Harris, Holly; Mallan, Kimberley M; Nambiar, Smita; Daniels, Lynne A

    2014-12-01

    Parental controlling feeding practices have been directly associated with maladaptive child eating behaviors, such as eating in the absence of hunger (EAH). The aims of this study were to examine EAH in very young children (3-4years old) and to investigate the association between maternal controlling feeding practices and energy intake from a standardized selection of snacks consumed 'in the absence of hunger'. Thirty-seven mother-child dyads enrolled in the NOURISH RCT participated in a modified EAH protocol conducted in the child's home. All children displayed EAH, despite 80% reporting to be full or very full following completion of lunch 15min earlier. The relationships between maternal and child covariates and controlling feeding practices and EAH were examined using non-parametric tests, and were stratified by child gender. For boys only, pressure to eat was positively associated with EAH. Neither restriction nor monitoring practices were associated with EAH in either boys or girls. Overall, the present findings suggest that gender differences in the relationship between maternal feeding practices and children's eating behaviors emerge early and should be considered in future research and intervention design. Copyright © 2014 Elsevier Ltd. All rights reserved.

  9. Standard Practice for Preparation of Aerospace Contamination Control Plans

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This practice is intended to assist in the preparation of formal plans for contamination control, especially of aerospace critical surfaces. Requirements may be established at the systems level, either by the customer or the systems integrator, or at the subsystem level. Subsystem requirements may be imposed by the responsible subsystem supplier or they may be flowed down from the systems organization (4.7). The extent of detail and level of cleanliness required can vary with the particular application and type of hardware being built, but all aspects of contamination control must be included in a final plan. Therefore, each of the following elements must be considered for inclusion in a contamination control plan (CCP): 1.1.1 Cleanliness requirements for deliverable hardware addressing particulate, molecular, or biological contaminants or combination thereof. Specify contamination limits and any budget allocations. 1.1.2 Implementation plans to achieve, verify, and maintain the specified cleanliness re...

  10. Research on control technology of hardware parallelism for marine controlled source electromagnetic transmitter

    Science.gov (United States)

    Wang, Meng; Deng, Ming; Luo, Xianhu; Zhao, Qingxian; Chen, Kai; Jing, Jianen

    2018-02-01

    The marine controlled source electromagnetic (CSEM) method has been recognized as an effective exploration method of shallow hydrocarbons around the world. We developed our own underwater marine CSEM transmitter that consisted of many functional modules with various response times. We previously adopted a centralized software-control technology to design the transmitter circuit topological structure. That structure probably generated a control disorder or malfunction. These undesirable conditions could lead to repeated recovery and deployment of the transmitter, which not only consumed time but also affected data continuity and establishment of stable and continuous CSEM field. We developed an instrument design concept named ‘control technology of hardware parallelism’. In this design, a noteworthy innovation of our new technology is to solve the above-mentioned problems at the physical and fundamental levels. We used several self-contained control-units to simultaneously accomplish the predetermined functions of the transmitter. The new solution relies on two technologies: multi-core embedded technology and multi-channel parallel optical-fiber data transmission technology. The first technology depends on many independent microcontrollers. Every microcontroller is only used to achieve a customized function. The second one relies on several multiple optical-fiber transmission channels realized by a complex programmable logic device and two optical-fiber conversion devices, which are used to establish a communication link between the shipboard monitoring and control-unit and underwater transmitter. We have conducted some marine experiments to verify the reliability and stability of the new method. In particular, the new technology used in the transmitter system could help us obtain more useful measured data in a limited time, improve real-time efficiency, and support the establishment of a stable CSEM field.

  11. Factors associated with good TB infection control practices among primary healthcare workers in the Free State Province, South Africa.

    Science.gov (United States)

    Engelbrecht, Michelle; Janse van Rensburg, André; Kigozi, Gladys; van Rensburg, Hcj Dingie

    2016-11-04

    Despite the availability of TB infection control guidelines, and good levels of healthcare worker knowledge about infection control, often these measures are not well implemented. This study sought to determine the factors associated with healthcare workers' good TB infection control practices in primary health care facilities in the Free State Province, South Africa. A cross-sectional self-administered survey among nurses (n = 202) and facility-based community healthcare workers (n = 34) as well as facility observations were undertaken at all 41 primary health care facilities in a selected district of the Free State Province. The majority of respondents were female (n = 200; 87.7 %) and the average age was 44.19 years (standard deviation ±10.82). Good levels of knowledge were recorded, with 42.8 % (n = 101) having an average score (i.e. 65-79 %) and 31.8 % (n = 75) a good score (i.e. ≥ 80 %). Most respondents (n = 189; 80.4 %) had positive attitudes towards TB infection control practices (i.e. ≥ 80 %). While good TB infection control practices were reported by 72.9 % (n = 161) of the respondents (i.e. ≥75 %), observations revealed this to not necessarily be the case. For every unit increase in attitudes, good practices increased 1.090 times (CI:1.016-1.169). Respondents with high levels of knowledge (≥80 %) were 4.029 (CI: 1.550-10.469) times more likely to have good practices when compared to respondents with poor levels of knowledge (control were the main factors associated with good infection control practices. Although many respondents reported good infection control practices - which was somewhat countered by the observations - there are areas that require attention, particularly those related to administrative controls and the use of personal protective equipment.

  12. Knowledge, attitude and practice of exercise for plasma blood glucose control among patients with type-2 diabetes.

    Science.gov (United States)

    Awotidebe, Taofeek O; Adedoyin, Rufus A; Afolabi, Mubaraq A; Opiyo, Rose

    2016-01-01

    Exercise plays significant role in the health outcomes of patients with diabetes, however, little is known about patients' knowledge of exercise for plasma blood glucose control among patients with type-2 diabetes (T2D). This study investigated knowledge, attitude and practice (KAP) of exercise for plasma blood glucose control among patients with T2D. This cross-sectional study recruited 299 patients with T2D (male=105; female=194) from selected government hospitals in Osun State, Nigeria using purposive sampling technique. Validated questionnaires were used to assess of exercise for plasma blood glucose control and socioeconomic status (SES) of the patients. Data were analysed using descriptive and inferential statistics. Alpha level was set at exercise whilst 269(90.0%) had negative attitude to exercise practice. Less than a third, 82(27.4%) engaged in exercise practice for plasma blood glucose control. There was significant association between knowledge and practice of exercise ((2)=12.535; p=0.002). Furthermore, significant associations were found between knowledge and gender ((2)=11.453; p=0.003), and socioeconomic status ((2)=29.127, p=0.001) but not associated with attitude towards exercise (p>0.05). Patients with demonstrated good knowledge of exercise for plasma blood glucose control but reported negative attitude and poor practice of exercise. Copyright © 2016. Published by Elsevier Ltd.

  13. Impact of implementing electronic clinical practice guidelines for the diagnosis, control and treatment of cardiovascular risk factors: A pre-post controlled study

    Directory of Open Access Journals (Sweden)

    Eva Comin

    2017-08-01

    Conclusions: Computerized clinical practice guidelines are an effective tool for the control and follow-up of patients diagnosed with hypertension, type 2 diabetes mellitus, and hypercholesterolaemia. The usefulness of computerized clinical practice guidelines to diagnose and adequately treat individuals with these disorders remains unclear.

  14. School-Based Obesity-Prevention Policies and Practices and Weight-Control Behaviors among Adolescents.

    Science.gov (United States)

    Larson, Nicole; Davey, Cynthia S; Caspi, Caitlin E; Kubik, Martha Y; Nanney, Marilyn S

    2017-02-01

    The promotion of healthy eating and physical activity within school settings is an important component of population-based strategies to prevent obesity; however, adolescents may be vulnerable to weight-related messages, as rapid development during this life stage often leads to preoccupation with body size and shape. This study examines secular trends in secondary school curricula topics relevant to the prevention of unhealthy weight-control behaviors; describes cross-sectional associations between weight-related curricula content and students' use of weight-control behaviors; and assesses whether implementation of school-based obesity-prevention policies/practices is longitudinally related to students' weight-control behaviors. The Minnesota School Health Profiles and Minnesota Student Survey (grades 9 and 12) data were used along with National Center for Education Statistics data to examine secular trends, cross-sectional associations (n=141 schools), and longitudinal associations (n=42 schools). Students self-reported their height and weight along with past-year use of healthy (eg, exercise), unhealthy (eg, fasting), and extreme (eg, use laxatives) weight-control behaviors. Descriptive statistics, generalized estimating equations, and generalized linear regression models accounting for school-level demographics. There was no observable pattern during the years 2008 to 2014 in the mean number of curricula topics addressing unhealthy weight-control behaviors, despite an increase in the prevalence of curricula addressing acceptance of body-size differences. Including three vs fewer weight-control topics and specifically including the topic of eating disorders in the curricula was related to a lower school-level percent of students using any extreme weight-control behaviors. In contrast, an overall measure of implementing school-based obesity-prevention policies/practices (eg, prohibited advertising) was unrelated to use of unhealthy or extreme behaviors

  15. Design and construction of the advanced photon source 352-MHz rf system switching control

    International Nuclear Information System (INIS)

    Horan, D.; Solita, L.; Reigle, D.; Dimonte, N.

    1997-01-01

    A switching control system has been designed and built to provide the capability of rapidly switching the waveguide and low-level cabling between different klystrons to operate the Advanced Photon Source storage ring in the event of a failure of a klystron system or to perform necessary repairs and preventative maintenance. The twelve possible modes of operation allow for complete redundancy of the booster synchrotron rf system and either a maximum of two storage ring rf systems to be completely off-line or one system to be used as a power source for an rf test stand. A programmable controller is used to send commands to intermediate control panels which interface to WR2300 waveguide switches and phase shifters, rf cavity interlock and low-level rf distribution systems, and klystron power supply controls for rapid reconfiguration of the rf systems in response to a mode-selection command. Mode selection is a local manual operation using a keyswitch arrangement which prevents more than one mode from being selected at a time. The programmable controller also monitors for hardware malfunction and guards against open-quotes hot-switchingclose quotes of the rf systems. The rf switching controls system is monitored via the Experimental Physics and Industrial Control System (EPICS) for remote system status check

  16. [The contact-free control of the functional state: the experience of its practical use].

    Science.gov (United States)

    Frolov, M V

    1992-01-01

    Application of contactless control method does not create any psychological or physical discomfort for a man and allows to realize diagnostics continuously for a long time, evidently or secretly. These properties of the control determine its effective application in practice. In the paper the data are given of the studies of the functional state of a man-operator using the parameters of the eyelids movements contactlessly recorded in infra-red rays, and the results of diagnostics of patients with depression by the characteristics of their speech, recorded from the microphone. The above data are obtained in practice.

  17. Oral hygiene practices and status of epileptics and controls in Lagos ...

    African Journals Online (AJOL)

    Bacterial plaque is the primary aetiologic agent in inflammatory periodontal disease. This study therefore aims to investigate the oral health practices and status of epileptics and controls. This will form the basis of a more detailed study on the periodontal status and treatment needs of epileptic patients. Materials and Method: ...

  18. Scrap supply in Bosnian after war situation - sources, quality, regulation and control

    International Nuclear Information System (INIS)

    Pihura, Dervis

    1999-01-01

    Before the war, the Bosnian foundry and steel industry were supplied with scrap partly from domestic sources but mainly from foreign market. The annual steel production before the war recorded 130,000 tonnes of casting and 2,000.000 tonnes of crude steel. Most of the scrap was imported to secure and stabilize the production. During and after the war, despite a significant loss of production, efforts have been made to return to the normal production level in many ways. In the wake of the war, there has been a growing concern over the import of radioactive contaminated metallurgical scrap or low quality raw materials which are uncontrolled or of unidentified sources. In this regard, it is urgently required to establish an effective system to prevent from, to detect and to control the flow of the radioactive contaminated metallurgical scrap. The system should be established in such a way that all sorts of radioactive metallurgical elements should be controlled and prevented from use in all the metallurgical manufacturing processes, ferrous and non-ferrous alike. The coverage of control should start from the border or (air) port checkpoint where the flow of the scrap begins to the final steel product. The control system should take a form of internationally common and acceptable standards and regulations. Equipments and measurement techniques should also be internationally common. (author)

  19. ADEX optimized adaptive controllers and systems from research to industrial practice

    CERN Document Server

    Martín-Sánchez, Juan M

    2015-01-01

    This book is a didactic explanation of the developments of predictive, adaptive predictive and optimized adaptive control, including the latest methodology of adaptive predictive expert (ADEX) control, and their practical applications. It is focused on the stability perspective, used in the introduction of these methodologies, and is divided into six parts, with exercises and real-time simulations provided for the reader as appropriate. ADEX Optimized Adaptive Controllers and Systems begins with the conceptual and intuitive knowledge of the technology and derives the stability conditions to be verified by the driver block and the adaptive mechanism of the optimized adaptive controller to guarantee achievement of desired control performance. The second and third parts are centered on the design of the driver block and adaptive mechanism, which verify these stability conditions. The authors then proceed to detail the stability theory that supports predictive, adaptive predictive and optimized adaptive control m...

  20. Air pollution control in practice

    International Nuclear Information System (INIS)

    Baum, F.

    1988-01-01

    The book offers a comprehensive treatment of the subject, from air pollution monitoring and effects on human and animal health, on plants and materials, to pollution reduction measures, practical applications, and legal regulations. It intends to give the air pollution expert a basis for developing practicable solutions. Apart from the 'classic' pollutants, also radioactive air pollution is gone into. (DG) With 366 figs., 190 tabs [de

  1. Force analysis of the advanced neutron source control rod drive latch mechanism

    International Nuclear Information System (INIS)

    Damiano, B.

    1989-01-01

    The Advanced Neutron Source reactor (ANS), a proposed Department of Energy research reactor currently undergoing conceptual design at the Oak Ridge National Laboratory (ORNL), will generate a thermal neutron flux approximating 10 30 M -2 emdash S -1 . The compact core necessary to produce this flux provides little space for the shim safety control rods, which are located in the central annulus of the core. Without proper control rod drive design, the control rod drive magnets (which hold the control rod latch in a ready-to-scram position) may be unable to support the required load due to their restricted size. This paper describes the force analysis performed on the control rod latch mechanism to determine the fraction of control rod weight transferred to the drive magnet. This information will be useful during latch, control rod drive and magnet design. 5 refs., 12 figs

  2. Evaluation of nonpoint-source contamination, Wisconsin: water year 1999

    Science.gov (United States)

    Walker, John F.; Graczyk, D.J.; Corsi, Steven R.; Wierl, J.A.; Owens, D.W.

    2001-01-01

    The objective of the watershed-management evaluation monitoring program in Wisconsin is to evaluate the effectiveness of best-management practices (BMPs) for controlling nonpoint-source pollution in rural and urban watersheds. This progress report provides a summary of the data collected by the U.S Geological Survey for the program and a discussion of the results from several different detailed analyses conducted within this program.

  3. The medical practice of euthanasia in Belgium and The Netherlands: legal notification, control and evaluation procedures.

    Science.gov (United States)

    Smets, Tinne; Bilsen, Johan; Cohen, Joachim; Rurup, Mette L; De Keyser, Els; Deliens, Luc

    2009-05-01

    To describe and compare current legal procedures for notifying, controlling and evaluating (NCE-procedures) euthanasia in Belgium and the Netherlands, and to discuss the implications for a safe and controllable euthanasia practice. We systematically studied and compared official documents relating to the Belgian and the Dutch NCE-procedures for euthanasia. In both countries, physicians are required to notify their cases to a review Committee, stimulating them to safeguard the quality of their euthanasia practice and to make societal control over the practice of euthanasia possible. However, the procedures in both countries differ. The main differences are that the Dutch notification and control procedures are more elaborate and transparent than the Belgian, and that the Belgian procedures are primarily anonymous, whereas the Dutch are not. Societal evaluation is made in both countries through the Committees' summary reports to Parliament. Transparent procedures like the Dutch may better facilitate societal control. Informing physicians about the law and the due care requirements for euthanasia, and systematic feedback about their medical actions are both pivotal to achieving efficient societal control and engendering the level of care needed when performing such far-reaching medical acts.

  4. The French Experience Regarding Peer Reviews to Improve the Safety and Security of Radioactive Sources

    International Nuclear Information System (INIS)

    Lachaume, J.-L.; Bélot, G.

    2015-01-01

    France has a 50 year history of control over radioactive sources. Convinced that peer reviews may be helpful to improve any regulatory system, France decided to experience a ‘full scope’ Integrated Regulatory Review Service mission in 2006 and its follow-up mission in 2009, including a review of the implementation of the Code of Conduct. The reviews, interviews and observations performed during these missions enabled the experts to have a thorough knowledge of the French system and to highlight its strengths and ways for improvements. Following these reviews, France decided to rely on its good practices, extend them as much as possible and to define, implement and address an action plan to improve its regulatory control over radioactive sources, while maintaining the prime responsibility on the operators. While good practices in the tracking of sources were maintained and slight evolutions were conducted in the safety regulations, licensing process, and inspection and enforcement actions, the major outcome of these reviews will obviously consist of the entrustment of the French Nuclear Safety Authority with the role of the regulatory authority for the security of radioactive sources and the implementation of dedicated provisions. (author)

  5. Recommended Practice: Creating Cyber Forensics Plans for Control Systems

    Energy Technology Data Exchange (ETDEWEB)

    Eric Cornelius; Mark Fabro

    2008-08-01

    issues and to accommodate for the diversity in both system and architecture types, a framework based in recommended practices to address forensics in the control systems domain is required. This framework must be fully flexible to allow for deployment into any control systems environment regardless of technologies used. Moreover, the framework and practices must provide for direction on the integration of modern network security technologies with traditionally closed systems, the result being a true defense-in-depth strategy for control systems architectures. This document takes the traditional concepts of cyber forensics and forensics engineering and provides direction regarding augmentation for control systems operational environments. The goal is to provide guidance to the reader with specifics relating to the complexity of cyber forensics for control systems, guidance to allow organizations to create a self-sustaining cyber forensics program, and guidance to support the maintenance and evolution of such programs. As the current control systems cyber security community of interest is without any specific direction on how to proceed with forensics in control systems environments, this information product is intended to be a first step.

  6. An Improved Current-Doubler Rectifier for the Marine Controlled Source Electromagnetic Transmitter

    Directory of Open Access Journals (Sweden)

    Hongxi Song

    2018-01-01

    Full Text Available High power marine controlled source electromagnetic transmitters have gained interest with applications in marine geological survey and mineral resources exploration. The direct current to direct current (DC-DC converter that is typically used in marine transmitters has some issues, as the insulated-gate bipolar transistor (IGBT tube cannot achieve zero-voltage switching (ZVS. In particular, lagging-leg switching cannot easily achieve ZVS. The conversion efficiency of the heat converter requires improvement. This paper proposes an improved current-doubler rectifier for the marine controlled source electromagnetic transmitter (ICDR-MCSET. Resonant inductance is increased and a blocking capacitor is added to the converter (DC-DC circuit, where the converter can achieve ZVS in a wide load range. This results in the effective decrease of the heating temperature and the improvement of transformation efficiency. Saber software simulation and a 20 KW electromagnetic transmitter are used to verify the results, which show that the method is feasible and effective.

  7. Strategic elements of steam cycle chemistry control practices at TXU's Comanche Peak steam electric station

    International Nuclear Information System (INIS)

    Fellers, B.; Stevens, J.; Nichols, G.

    2002-01-01

    Early industry experience defined the critical importance of Chemistry Control Practices to maintaining long-term performance of PWR steam generators. These lessons provided the impetus for a number of innovations and alternate practices at Comanche Peak. For example, advanced amine investigations and implementation of results provided record low iron transport and deposition. The benefits of the surface-active properties of dimethyl-amine exceeded initial expectations. Operation of pre-coat polishers and steam generator blowdown demineralizers in the amine cycle enabled optimization of amine concentrations and stable pH control. The strategy for coordinated control of oxygen and hydrazine dosing complemented the advanced amine program for protective oxide stabilization. Additionally, a proactive chemical cleaning was performed on Unit 1 to prevent degradations from general fouling of steam generator tube-tube support plate (TSP) and top-of-tubesheet (TTS) crevices. This paper shares the results of these innovations and practices. Also, the bases, theory, and philosophy supporting the strategic elements of program will be presented. (authors)

  8. Early Versus Delayed Source Control in Open Abdomen Management for Severe Intra-abdominal Infections: A Retrospective Analysis on 111 Cases.

    Science.gov (United States)

    Rausei, Stefano; Pappalardo, Vincenzo; Ruspi, Laura; Colella, Antonio; Giudici, Simone; Ardita, Vincenzo; Frattini, Francesco; Rovera, Francesca; Boni, Luigi; Dionigi, Gianlorenzo

    2018-03-01

    Time to source control plays a determinant prognostic role in patients having severe intra-abdominal infections (IAIs). Open abdomen (OA) management became an effective treatment option for peritonitis. Aim of this study was to analyze the correlation between time to source control and outcome in patients presenting with abdominal sepsis and treated by OA. We retrospectively analyzed 111 patients affected by abdominal sepsis and treated with OA from May 2007 to May 2015. Patients were classified according to time interval from first patient evaluation to source control. The end points were intra-hospital mortality and primary fascial closure rate. The in-hospital mortality rate was 21.6% (24/111), and the primary fascial closure rate was 90.9% (101/111). A time to source control ≥6 h resulted significantly associated with a poor prognosis and a lower fascial closure rate (mortality 27.0 vs 9.0%, p = 0.04; primary fascial closure 86 vs 100%, p = 0.02). We observed a direct increase in mortality (and a reduction in closure rate) for each 6-h delay in surgery to source control. Early source control using OA management significantly improves outcome of patients with severe IAIs. This damage control approach well fits to the treatment of time-related conditions, particularly in case of critically ill patients.

  9. A concealed observational study of infection control and safe injection practices in Jordanian governmental hospitals.

    Science.gov (United States)

    Al-Rawajfah, Omar M; Tubaishat, Ahmad

    2017-10-01

    The recognized international organizations on infection prevention recommend using an observational method as the gold standard procedure for assessing health care professional's compliance with standard infection control practices. However, observational studies are rarely used in Jordanian infection control studies. This study aimed to evaluate injection practices among nurses working in Jordanian governmental hospitals. A cross-sectional concealed observational design is used for this study. A convenience sampling technique was used to recruit a sample of nurses working in governmental hospitals in Jordan. Participants were unaware of the time and observer during the observation episode. A total of 384 nurses from 9 different hospitals participated in the study. A total of 835 injections events were observed, of which 73.9% were performed without handwashing, 64.5% without gloving, and 27.5% were followed by needle recapping. Handwashing rate was the lowest (18.9%) when injections were performed by beginner nurses. Subcutaneous injections were associated with the lowest rate (26.7%) of postinjection handwashing compared with other routes. This study demonstrates the need for focused and effective infection control educational programs in Jordanian hospitals. Future studies should consider exploring the whole infection control practices related to waste disposal and the roles of the infection control nurse in this process in Jordanian hospitals. Copyright © 2017 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  10. Monitoring Hydraulic Fracturing Using Ground-Based Controlled Source Electromagnetics

    Science.gov (United States)

    Hickey, M. S.; Trevino, S., III; Everett, M. E.

    2017-12-01

    Hydraulic fracturing allows hydrocarbon production in low permeability formations. Imaging the distribution of fluid used to create a hydraulic fracture can aid in the characterization of fracture properties such as extent of plume penetration as well as fracture azimuth and symmetry. This could contribute to improving the efficiency of an operation, for example, in helping to determine ideal well spacing or the need to refracture a zone. A ground-based controlled-source electromagnetics (CSEM) technique is ideal for imaging the fluid due to the change in field caused by the difference in the conductive properties of the fluid when compared to the background. With advances in high signal to noise recording equipment, coupled with a high-power, broadband transmitter we can show hydraulic fracture extent and azimuth with minimal processing. A 3D finite element code is used to model the complete well casing along with the layered subsurface. This forward model is used to optimize the survey design and isolate the band of frequencies with the best response. In the field, the results of the modeling are also used to create a custom pseudorandom numeric (PRN) code to control the frequencies transmitted through a grounded dipole source. The receivers record the surface voltage across two grounded dipoles, one parallel and one perpendicular to the transmitter. The data are presented as the displays of amplitude ratios across several frequencies with the associated spatial information. In this presentation, we show multiple field results in multiple basins in the United States along with the CSEM theory used to create the survey designs.

  11. A survey of quality assurance practices in biomedical open source software projects.

    Science.gov (United States)

    Koru, Günes; El Emam, Khaled; Neisa, Angelica; Umarji, Medha

    2007-05-07

    Open source (OS) software is continuously gaining recognition and use in the biomedical domain, for example, in health informatics and bioinformatics. Given the mission critical nature of applications in this domain and their potential impact on patient safety, it is important to understand to what degree and how effectively biomedical OS developers perform standard quality assurance (QA) activities such as peer reviews and testing. This would allow the users of biomedical OS software to better understand the quality risks, if any, and the developers to identify process improvement opportunities to produce higher quality software. A survey of developers working on biomedical OS projects was conducted to examine the QA activities that are performed. We took a descriptive approach to summarize the implementation of QA activities and then examined some of the factors that may be related to the implementation of such practices. Our descriptive results show that 63% (95% CI, 54-72) of projects did not include peer reviews in their development process, while 82% (95% CI, 75-89) did include testing. Approximately 74% (95% CI, 67-81) of developers did not have a background in computing, 80% (95% CI, 74-87) were paid for their contributions to the project, and 52% (95% CI, 43-60) had PhDs. A multivariate logistic regression model to predict the implementation of peer reviews was not significant (likelihood ratio test = 16.86, 9 df, P = .051) and neither was a model to predict the implementation of testing (likelihood ratio test = 3.34, 9 df, P = .95). Less attention is paid to peer review than testing. However, the former is a complementary, and necessary, QA practice rather than an alternative. Therefore, one can argue that there are quality risks, at least at this point in time, in transitioning biomedical OS software into any critical settings that may have operational, financial, or safety implications. Developers of biomedical OS applications should invest more effort

  12. The development of control processes supporting source memory discrimination as revealed by event-related potentials.

    Science.gov (United States)

    de Chastelaine, Marianne; Friedman, David; Cycowicz, Yael M

    2007-08-01

    Improvement in source memory performance throughout childhood is thought to be mediated by the development of executive control. As postretrieval control processes may be better time-locked to the recognition response rather than the retrieval cue, the development of processes underlying source memory was investigated with both stimulus- and response-locked event-related potentials (ERPs). These were recorded in children, adolescents, and adults during a recognition memory exclusion task. Green- and red-outlined pictures were studied, but were tested in black outline. The test requirement was to endorse old items shown in one study color ("targets") and to reject new items along with old items shown in the alternative study color ("nontargets"). Source memory improved with age. All age groups retrieved target and nontarget memories as reflected by reliable parietal episodic memory (EM) effects, a stimulus-locked ERP correlate of recollection. Response-locked ERPs to targets and nontargets diverged in all groups prior to the response, although this occurred at an increasingly earlier time point with age. We suggest these findings reflect the implementation of attentional control mechanisms to enhance target memories and facilitate response selection with the greatest and least success, respectively, in adults and children. In adults only, response-locked ERPs revealed an early-onsetting parietal negativity for nontargets, but not for targets. This was suggested to reflect adults' ability to consistently inhibit prepotent target responses for nontargets. The findings support the notion that the development of source memory relies on the maturation of control processes that serve to enhance accurate selection of task-relevant memories.

  13. Effects of N Fertilizer Sources and Tillage Practices on NH3 Volatilization, Grain Yield, and N Use Efficiency of Rice Fields in Central China

    Directory of Open Access Journals (Sweden)

    Tianqi Liu

    2018-03-01

    Full Text Available Tillage practices and nitrogen (N sources are important factors affecting rice production. Few studies, however, have examined the interactions between tillage practices and N fertilizer sources on NH3 volatilization, nitrogen use efficiency (NUE, and rice grain yield. This study aimed to investigate the effects of N fertilizer sources (no N fertilizer, inorganic N fertilizer, organic N fertilizer alone, organic N fertilizer plus inorganic N fertilizer, and slow-release N fertilizer plus inorganic N fertilizer and tillage practices (no-tillage [NT] and conventional intensive tillage [CT] on NH3 flux, grain yield, and NUE in the rice field of central China. N sources significantly affected NH3 volatilization, as the cumulative volatilization from the treatments of inorganic N fertilizer, organic N fertilizer, organic N fertilizer plus inorganic N fertilizer, slow-release N fertilizer plus inorganic N fertilizer was 4.19, 2.13, 3.42, and 2.23 folds in 2013, and 2.49, 1.68, 2.08, and 1.85 folds in 2014 compared with that under no N fertilizer treatment, respectively. The organic N fertilizer treatment had the lowest grain yield and NUE among all N fertilizer treatments, while slow-release N fertilizer plus inorganic N fertilizer treatment led to relatively higher grain yield and the greatest N use efficiency. Moreover, NT only markedly increased NH3 volatilization from basal fertilizer by 10–14% in average compared with CT, but had no obvious effects on total volatilization during the whole seasons. Tillage practices had no significant effects on grain yield and NUE. Our study suggested that the combination of slow-release N fertilizer plus inorganic N fertilizer and NT might be a sustainable method for mitigating greenhouse gas and NH3 emissions and improving grain yield and NUE in paddy fields of central China.

  14. Effects of N Fertilizer Sources and Tillage Practices on NH3 Volatilization, Grain Yield, and N Use Efficiency of Rice Fields in Central China.

    Science.gov (United States)

    Liu, Tianqi; Huang, Jinfeng; Chai, Kaibin; Cao, Cougui; Li, Chengfang

    2018-01-01

    Tillage practices and nitrogen (N) sources are important factors affecting rice production. Few studies, however, have examined the interactions between tillage practices and N fertilizer sources on NH 3 volatilization, nitrogen use efficiency (NUE), and rice grain yield. This study aimed to investigate the effects of N fertilizer sources (no N fertilizer, inorganic N fertilizer, organic N fertilizer alone, organic N fertilizer plus inorganic N fertilizer, and slow-release N fertilizer plus inorganic N fertilizer) and tillage practices (no-tillage [NT] and conventional intensive tillage [CT]) on NH 3 flux, grain yield, and NUE in the rice field of central China. N sources significantly affected NH 3 volatilization, as the cumulative volatilization from the treatments of inorganic N fertilizer, organic N fertilizer, organic N fertilizer plus inorganic N fertilizer, slow-release N fertilizer plus inorganic N fertilizer was 4.19, 2.13, 3.42, and 2.23 folds in 2013, and 2.49, 1.68, 2.08, and 1.85 folds in 2014 compared with that under no N fertilizer treatment, respectively. The organic N fertilizer treatment had the lowest grain yield and NUE among all N fertilizer treatments, while slow-release N fertilizer plus inorganic N fertilizer treatment led to relatively higher grain yield and the greatest N use efficiency. Moreover, NT only markedly increased NH 3 volatilization from basal fertilizer by 10-14% in average compared with CT, but had no obvious effects on total volatilization during the whole seasons. Tillage practices had no significant effects on grain yield and NUE. Our study suggested that the combination of slow-release N fertilizer plus inorganic N fertilizer and NT might be a sustainable method for mitigating greenhouse gas and NH 3 emissions and improving grain yield and NUE in paddy fields of central China.

  15. Control system integration

    CERN Document Server

    Shea, T J

    2008-01-01

    This lecture begins with a definition of an accelerator control system, and then reviews the control system architectures that have been deployed at the larger accelerator facilities. This discussion naturally leads to identification of the major subsystems and their interfaces. We shall explore general strategies for integrating intelligent devices and signal processing subsystems based on gate arrays and programmable DSPs. The following topics will also be covered: physical packaging; timing and synchronization; local and global communication technologies; interfacing to machine protection systems; remote debugging; configuration management and source code control; and integration of commercial software tools. Several practical realizations will be presented.

  16. [Research on spatial differentiation of urban stormwater runoff quality by source area monitoring].

    Science.gov (United States)

    Li, Li-Qing; Zhu, Ren-Xiao; Guo, Shu-Gang; Yin, Cheng-Qing

    2010-12-01

    Runoff samples were collected from 14 source areas in Hanyang district during four rain events in an attempt to investigate the spatial differentiation and influencing factors of urban stormwater runoff quality. The outcomes are expected to offer practical guidance in sources control of urban runoff pollution. The results revealed that particle-bound proportion of chemical oxygen demand (COD), total nitrogen (TN), and total phosphorus (TP) in stormwater runoff were 58% +/- 17%, 65% +/- 13% and 92% +/- 6%, respectively. The fractions of ammonia, nitrate and dissolved organic nitrogen were homogeneous in dissolved nitrogen composition. Urban surface function, traffic volume, land use, population density, and street sweeping practice are the main factors determining spatial differentiation of urban surface runoff quality. The highest magnitude of urban stormwater runoff pollution was expected in the old urban residential area, followed by general residential with restaurants, commercial and transport area, new developments and green land. In addition, the magnitude of road stormwater runoff pollution is positively correlated to traffic volume, in the following order: the first trunk road > the second trunk road > minor road. Street sweeping and critical source areas controls should be implemented to mitigate the adverse effects of urban stormwater runoff on receive waters.

  17. Internal Quality Control Practices in Coagulation Laboratories: recommendations based on a patterns-of-practice survey.

    Science.gov (United States)

    McFarlane, A; Aslan, B; Raby, A; Moffat, K A; Selby, R; Padmore, R

    2015-12-01

    Internal quality control (IQC) procedures are crucial for ensuring accurate patient test results. The IQMH Centre for Proficiency Testing conducted a web-based survey to gather information on the current IQC practices in coagulation testing. A questionnaire was distributed to 174 Ontario laboratories licensed to perform prothrombin time (PT) and activated partial thromboplastin time (APTT). All laboratories reported using two levels of commercial QC (CQC); 12% incorporate pooled patient plasma into their IQC program; >68% run CQC at the beginning of each shift; 56% following maintenance, with reagent changes, during a shift, or with every repeat sample; 6% only run CQC at the beginning of the day and 25% when the instruments have been idle for a defined period of time. IQC run frequency was determined by manufacturer recommendations (71%) but also influenced by the stability of test (27%), clinical impact of an incorrect test result (25%), and sample's batch number (10%). IQC was monitored using preset limits based on standard deviation (66%), precision goals (46%), or allowable performance limits (36%). 95% use multirules. Failure actions include repeating the IQC (90%) and reporting patient results; if repeat passes, 42% perform repeat analysis of all patient samples from last acceptable IQC. Variability exists in coagulation IQC practices among Ontario clinical laboratories. The recommendations presented here would be useful in encouraging standardized IQC practices. © 2015 John Wiley & Sons Ltd.

  18. Reproducibility and Practical Adoption of GEOBIA with Open-Source Software in Docker Containers

    Directory of Open Access Journals (Sweden)

    Christian Knoth

    2017-03-01

    Full Text Available Geographic Object-Based Image Analysis (GEOBIA mostly uses proprietary software,but the interest in Free and Open-Source Software (FOSS for GEOBIA is growing. This interest stems not only from cost savings, but also from benefits concerning reproducibility and collaboration. Technical challenges hamper practical reproducibility, especially when multiple software packages are required to conduct an analysis. In this study, we use containerization to package a GEOBIA workflow in a well-defined FOSS environment. We explore the approach using two software stacks to perform an exemplary analysis detecting destruction of buildings in bi-temporal images of a conflict area. The analysis combines feature extraction techniques with segmentation and object-based analysis to detect changes using automatically-defined local reference values and to distinguish disappeared buildings from non-target structures. The resulting workflow is published as FOSS comprising both the model and data in a ready to use Docker image and a user interface for interaction with the containerized workflow. The presented solution advances GEOBIA in the following aspects: higher transparency of methodology; easier reuse and adaption of workflows; better transferability between operating systems; complete description of the software environment; and easy application of workflows by image analysis experts and non-experts. As a result, it promotes not only the reproducibility of GEOBIA, but also its practical adoption.

  19. Forestry best management practices and sediment control at skidder stream crossings

    Science.gov (United States)

    Laura R. Wear; W. Michael Aust; M. Chad Bolding; Brian D. Strahm; Andrew C. Dolloff

    2015-01-01

    Stream crossings for skid trails have high sediment delivery ratios. Forestry Best Management Practices (BMPs) have proven to be effective for erosion control, but few studies have quantified the impact of various levels of BMPs on sedimentation. In this study, three skid-trail stream-crossing BMP treatments were installed on nine operational stream crossings (three...

  20. Control Towers in Supply Chain Management - Past and Future

    Directory of Open Access Journals (Sweden)

    Anna Trzuskawska-Grzesińska

    2017-02-01

    Full Text Available The global economy requires global supply chain management which relies on visibility and responsiveness. Determinants such as: information technology tools, process knowledge, sales and operations planning experiences, etc., enable the formation of theory and practice for the supply chain control tower concept. The goal of the research paper is to identify business examples of different approaches to the supply chain control tower in the past and initiate a discussion on their future. This paper synthesizes past control tower practices and identifies possible future trends. The author performed: literature analysis, three selected companies' case studies and comparative analyses. As the control towers evolve, while supply chains are transforming continuous, update from the market is needed. The research findings showed the selected companies, in the future, perceived control tower's activities as a potential source of revenue not just solely a source of cost and time optimization as well as a source of value added to customer. The researched control towers were built and still they are developed. The business frequently changes and requires control towers to be adjusted, reengineered and adaptive. The researched control towers are needed to keep control over supply chain while it is transforming. There is a differentiation between the supply chain control towers, logistic services control towers and reverse supply chain control towers. An integration mechanism between the control towers would be necessary to assure entire supply chain visibility and orchestration. The research also shows the knowledge gap regarding the control towers in supply chain, specially their possible configurations and future.

  1. Development and operation of a computerized source controller for a gamma calibration well

    International Nuclear Information System (INIS)

    Halliburton, R.E.

    1986-01-01

    In the 1950s, the need for an accurately reproducible, real-time gamma calibration facility at the Oak Ridge National Laboratory (ORNL) was met with a manually operated radium source housed in a calibration well. This arrangement was quite satisfactory in the early days but was not able to keep pace with the increasing number of instruments necessary to support an expanding health physics program. Consequently, the hand crank was replaced by an electric motor in the early 1960s. This improvement made it possible to move the source at speeds up to 7 cm/s, resulting in a major increase in efficiency. This configuration served reliably for two decades but, by the 1980s, component aging and the growing scarcity of replacement parts led to the development of a third-generation source controller. The electric motor and vacuum-tube-driven power supply were replaced with a solid state power supply and a stepper motor interfaced to a microcomputer. The software written to operate the system is menu-driven, user-friendly, and provides the greatest flexibility and ease of use while minimizing learning time. The development and use of this control system will be discussed

  2. Variations of pollution sources of Cu in Jiaozhou Bay 1982-1986

    Science.gov (United States)

    Yang, Dongfang; Li, Haixia; Wang, Qi; Ding, Jun; Zhang, Longlei

    2017-12-01

    Cu pollution in marine bays has been one of the critical environmental issues in the whole world, and understanding the variations of the pollution sources is essential to environmental protection. This paper identified the sources of Cu in Jiaozhou Bay during 1982-1986, and revealed the variations of the sources. Results showed that there were five Cu sources during study years including marine current, stream flow, island top, overland runoff and marine traffic, respectively, whose source strengths were varying from 0.39-20.60 μg L-1, 0.37-10.57 μg L-1, 0.77-4.86 μg L-1, 2.28-3.56 μg L-1, 9.48 μg L-1, respectively. These findings were helpful information in decision-making of pollution control and environmental remediation practice.

  3. Digital Control Techniques Based on Voltage Source Inverters in Renewable Energy Applications: A Review

    Directory of Open Access Journals (Sweden)

    Sohaib Tahir

    2018-02-01

    Full Text Available In the modern era, distributed generation is considered as an alternative source for power generation. Especially, need of the time is to provide the three-phase loads with smooth sinusoidal voltages having fixed frequency and amplitude. A common solution is the integration of power electronics converters in the systems for connecting distributed generation systems to the stand-alone loads. Thus, the presence of suitable control techniques, in the power electronic converters, for robust stability, abrupt response, optimal tracking ability and error eradication are inevitable. A comprehensive review based on design, analysis, validation of the most suitable digital control techniques and the options available for the researchers for improving the power quality is presented in this paper with their pros and cons. Comparisons based on the cost, schemes, performance, modulation techniques and coordinates system are also presented. Finally, the paper describes the performance evaluation of the control schemes on a voltage source inverter (VSI and proposes the different aspects to be considered for selecting a power electronics inverter topology, reference frames, filters, as well as control strategy.

  4. Resolution 25/98 Regulation of Authorization of Practice Associated to the Radiations Ionizing Employment

    International Nuclear Information System (INIS)

    1998-01-01

    The present regulation has as objective to establish the general precepts that regulate the demands for the authorization of practices associated to the employment of ionizing radiations and their sources, with a view to guaranteeing the protection of the life, health, possessions and environment. Chapter I. is defined the objective and scope of the resolution, besides the terms and definitions. Chapter II, the Classification of the practices associated to the employment of the ionizing radiations. Chapter III try about the Regulatory Control of the practices and their sources. Chapter IV. the Procedures for the applications. Chapter V. procedure of Authorizations; and Chapter IV. Amendment, Modification, Renovation, Suspension and Renovation of Authorizations. Also a disposition referred to the validity of previous authorizations and 3 finals dispositions

  5. Assessment and promotion of safety culture in medical practices using sources of ionizing radiation. The Cuban experience

    International Nuclear Information System (INIS)

    Ferro Fernandez, Ruben; Guillen Campos, Alba; Arnau Fernandez, Alma

    2008-01-01

    Full text: The lessons learned from several radiological accidents in medical and industrial practices using sources of ionization radiation show that a fragile safety culture in the organizations and the human error were the most important contributors to such events. The high contribution of human factors to safety of radiotherapy treatment process have been also revealed by the results of a recent study on Probabilistic Safety Assessment to this process conducted in the framework of the Extra budgetary Programme on Nuclear and Radiological Safety in Iberian-America. Nevertheless non considerable efforts are appreciated around the world to investigate and develop methods and techniques to assess and promote a strong safety culture in those practices as it has been happening in other sectors like nuclear power, chemical, commercial aviation and oil industry. The Cuban Nuclear Regulatory Authority has in course a National Program for Promoting and Assessment of Safety Culture in organizations using sources of ionizing radiation. As part of this program, during the 2007 year, a pilot study with this purpose was carried out Two Radiotherapy and Nuclear Medicine Units were selected for this pilot study, where managers and specialists were interviewed, a safety culture survey was executed and a final report was prepared with several recommendations to be taking account by Regulator for designing its regulatory strategy on safety culture for medical practices and by users to increase their safety culture level. This paper describes the methodology used to organize, prepare, execute and report the results, findings and recommendations of this kind of review, the benefits and main difficulties encountered during this effort and the perspective and suggestions that, in opinion of the authors of this paper, are important to take into account in the field of radiological safety culture in the near future. (author)

  6. Self-Control of Task Difficulty During Early Practice Promotes Motor Skill Learning.

    Science.gov (United States)

    Andrieux, Mathieu; Boutin, Arnaud; Thon, Bernard

    2016-01-01

    This study was designed to determine whether the effect of self-control of task difficulty on motor learning is a function of the period of self-control administration. In a complex anticipation-coincidence task that required participants to intercept 3 targets with a virtual racquet, the task difficulty was either self-controlled or imposed to the participants in the two phases of the acquisition session. First, the results confirmed the beneficial effects of self-control over fully prescribed conditions. Second, the authors also demonstrated that a partial self-control of task difficulty better promotes learning than does a complete self-controlled procedure. Overall, the results revealed that these benefits are increased when this choice is allowed during early practice. The findings are discussed in terms of theoretical and applied perspectives.

  7. Importance of Multifaceted Approaches in Infection Control: A Practical Experience from an Outbreak Investigation.

    Directory of Open Access Journals (Sweden)

    Nina Katharina Stock

    Full Text Available This study presents the results of a multidisciplinary, nosocomial MRSA outbreak investigation in an 8-bed medical intensive care unit (ICU. The identification of seven MRSA positive patients in the beginning of 2014 led to the closure of the ward for several weeks. A multidisciplinary, retrospective investigation was initiated in order to identify the reason and the source for the outbreak, describe MRSA transmission in the department and identify limitations in infection control.The investigation comprised an epidemiological description of MRSA cases from 2012 to 2014 and a characterization of MRSA isolates, including phage-, spa- and PFGE-typing. Additionally, MRSA screening was performed from the hospital staff and the environment. To identify the reason for the outbreak, work-related, psychological and behavioral factors were investigated by impartial audits and staff interviews.Thirty-one MRSA cases were registered during the study period, and 36 isolates were investigated. Molecular typing determined the outbreak strain (phage type 54/812, PFGE type A4, spa type t003 and identified the probable index case. Nasal carriage in one employee and a high environmental contamination with the outbreak strain was documented. Important gaps in nursing procedures and general management were identified. Elevated stress levels and communication problems preceded the outbreak. Compliance with hand hygiene and isolation procedures was evaluated as appropriate.This study demonstrates the complexity of controlling hospital-associated infections. The combined use of different typing methods is beneficial for outbreak investigations. Psychological, behavioral and other work-related factors have an important impact on the spread of nosocomial pathogens. These factors should be addressed and integrated in routine infection control practice.

  8. Disrupting gatekeeping practices: Journalists' source selection in times of crisis.

    Science.gov (United States)

    van der Meer, Toni G L A; Verhoeven, Piet; Beentjes, Johannes W J; Vliegenthart, Rens

    2017-10-01

    As gatekeepers, journalists have the power to select the sources that get a voice in crisis coverage. The aim of this study is to find out how journalists select sources during a crisis. In a survey, journalists were asked how they assess the following sources during an organizational crisis: news agencies, an organization undergoing a crisis, and the general public. The sample consisted of 214 Dutch experienced journalists who at least once covered a crisis. Using structural equation modeling, sources' likelihood of being included in the news was predicted using five source characteristics: credibility, knowledge, willingness, timeliness, and the relationship with the journalist. Findings indicated that during a crisis, news agencies are most likely to be included in the news, followed by the public, and finally the organization. The significance of the five source characteristics is dependent on source type. For example, to be used in the news, news agencies and organizations should be mainly evaluated as knowledgeable, whereas information from the public should be both credible and timely. In addition, organizations should not be seen as too willing or too eager to communicate. The findings imply that, during a crisis, journalists remain critical gatekeepers; however, they rely mainly on familiar sources.

  9. Mixed Waste Management Facility (MWMF) Old Burial Ground (OBG) source control technology and inventory study

    Energy Technology Data Exchange (ETDEWEB)

    Flach, G.P.; Rehder, T.E.; Kanzleiter, J.P.

    1996-10-02

    This report has been developed to support information needs for wastes buried in the Burial Ground Complex. Information discussed is presented in a total of four individual attachments. The general focus of this report is to collect information on estimated source inventories, leaching studies, source control technologies, and to provide information on modeling parameters and associated data deficiencies.

  10. Mixed Waste Management Facility (MWMF) Old Burial Ground (OBG) source control technology and inventory study

    International Nuclear Information System (INIS)

    Flach, G.P.; Rehder, T.E.; Kanzleiter, J.P.

    1996-01-01

    This report has been developed to support information needs for wastes buried in the Burial Ground Complex. Information discussed is presented in a total of four individual attachments. The general focus of this report is to collect information on estimated source inventories, leaching studies, source control technologies, and to provide information on modeling parameters and associated data deficiencies

  11. Evaluation of stormwater micropollutant source control and end-of-pipe control strategies using an uncertainty-calibrated integrated dynamic simulation model

    DEFF Research Database (Denmark)

    Vezzaro, Luca; Sharma, Anitha Kumari; Ledin, Anna

    2015-01-01

    (copper, zinc) and organic compounds (fluoranthene). MP fluxes were estimated by using an integrated dynamic model, in combination with stormwater quality measurements. MP sources were identified by using GIS land usage data, runoff quality was simulated by using a conceptual accumulation/washoff model......The estimation of micropollutant (MP) fluxes in stormwater systems is a fundamental prerequisite when preparing strategies to reduce stormwater MP discharges to natural waters. Dynamic integrated models can be important tools in this step, as they can be used to integrate the limited data provided...... by monitoring campaigns and to evaluate the performance of different strategies based on model simulation results. This study presents an example where six different control strategies, including both source-control and end-of-pipe treatment, were compared. The comparison focused on fluxes of heavy metals...

  12. A new focalize of quality auditorship for documentation control. A practical case

    International Nuclear Information System (INIS)

    Young, R.B.; Malanij, D.

    1994-01-01

    Available as short communication only. A practical case of auditorship for Documentation Control System is described, showing the increase of efficiency when operated in the concept of Business Process Improvement, and this focalize is compatible with the nuclear area requirements. (C.G.C.). 2 refs

  13. Exposure control practices for administering nitrous oxide: A survey of dentists, dental hygienists, and dental assistants.

    Science.gov (United States)

    Boiano, James M; Steege, Andrea L; Sweeney, Marie H

    2017-06-01

    Engineering, administrative, and work practice controls have been recommended for many years to minimize exposure to nitrous oxide during dental procedures. To better understand the extent to which these exposure controls are used, the NIOSH Health and Safety Practices Survey of Healthcare Workers was conducted among members of professional practice organizations representing dentists, dental hygienists and dental assistants. The anonymous, modular, web-based survey was completed by 284 dental professionals in private practice who administered nitrous oxide to adult and/or pediatric patients in the seven days prior to the survey. Use of primary engineering controls (i.e., nasal scavenging mask and/or local exhaust ventilation (LEV) near the patient's mouth) was nearly universal, reported by 93% and 96% of respondents who administered to adult (A) and pediatric (P) patients, respectively. However, adherence to other recommended precautionary practices were lacking to varying degrees, and were essentially no different among those administering nitrous oxide to adult or pediatric patients. Examples of work practices which increase exposure risk, expressed as percent of respondents, included: not checking nitrous oxide equipment for leaks (41% A; 48% P); starting nitrous oxide gas flow before delivery mask or airway mask was applied to patient (13% A; 12% P); and not turning off nitrous oxide gas flow before turning off oxygen flow to the patient (8% A; 7% P). Absence of standard procedures to minimize worker exposure to nitrous oxide (13% of all respondents) and not being trained on safe handling and administration of nitrous oxide (3%) were examples of breaches of administrative controls which may also increase exposure risk. Successful management of nitrous oxide emissions should include properly fitted nasal scavenging masks, supplemental LEV (when nitrous oxide levels cannot be adequately controlled using nasal masks alone), adequate general ventilation, regular

  14. Sensitivity of the near-surface vertical electric field land Controlled-Source Electromagnetic monitoring

    NARCIS (Netherlands)

    Schaller, A.M.; Hunziker, J.W.; Streich, R.; Drijkoningen, G.G.

    2014-01-01

    We investigate potential benefits of measuring the vertical electric field component in addition to the routinely measured horizontal electric field components in onshore time-lapse controlled-source electromagnetics. Synthetic electromagnetic data based on a model of the Schoonebeek onshore oil

  15. Source splitting via the point source method

    International Nuclear Information System (INIS)

    Potthast, Roland; Fazi, Filippo M; Nelson, Philip A

    2010-01-01

    We introduce a new algorithm for source identification and field splitting based on the point source method (Potthast 1998 A point-source method for inverse acoustic and electromagnetic obstacle scattering problems IMA J. Appl. Math. 61 119–40, Potthast R 1996 A fast new method to solve inverse scattering problems Inverse Problems 12 731–42). The task is to separate the sound fields u j , j = 1, ..., n of n element of N sound sources supported in different bounded domains G 1 , ..., G n in R 3 from measurements of the field on some microphone array—mathematically speaking from the knowledge of the sum of the fields u = u 1 + ... + u n on some open subset Λ of a plane. The main idea of the scheme is to calculate filter functions g 1 ,…, g n , n element of N, to construct u l for l = 1, ..., n from u| Λ in the form u l (x) = ∫ Λ g l,x (y)u(y)ds(y), l=1,... n. (1) We will provide the complete mathematical theory for the field splitting via the point source method. In particular, we describe uniqueness, solvability of the problem and convergence and stability of the algorithm. In the second part we describe the practical realization of the splitting for real data measurements carried out at the Institute for Sound and Vibration Research at Southampton, UK. A practical demonstration of the original recording and the splitting results for real data is available online

  16. Controlling solar light and heat in a forest by managing shadow sources

    Science.gov (United States)

    Howard G. Halverson; James L. Smith

    1974-01-01

    Control of solar light and heat to develop the proper growth environment is a desirable goal in forest management. The amount of sunlight and heat reaching the surface is affected by shadows cast by nearby objects, including trees. In timbered areas, the type of forest management practiced can help develop desired microclimates. The results depend on the size and...

  17. A survey of infection control practices of consultant anaesthesiologists in teaching hospitals of pakistan

    International Nuclear Information System (INIS)

    Yaqub, K.M.; Tariq, M.; Janjua, S.; Masroor, R.

    2007-01-01

    To determine the infection control practices of Anaesthesiologist in the teaching hospitals of Pakistan. Cross-sectional survey. The survey was closed after allowing 6 months for return of the replies. A questionnaire was distributed to 170 consultant anaesthesiologist randomly selected from all over Pakistan. Out of these, 90 (53%) were returned and analyzed. To reduce self-report bias, the forms were filled anonymously. Thirty four percent of the respondents always used masks, and only 9% used gloves in their every day practice. Only 18% of respondents stated that they always washed their hands after every patient contact and 54% reported that they always used aseptic technique for placing an indwelling cannula. Most respondents had a good knowledge of universal precautions for prevention of occupational transmission of infection. Five percent of the anaesthetists reported frequently or always reusing syringes for more than one patient. The practice of reusing syringes was significantly greater when the same consultants were anaesthetizing patients in private clinics rather than in their primary institutions (p 5, in 58% of cases. Whereas most responding anaesthesiologist exhibit appropriate infection control behaviour, there are several potentially hazardous practices that continue unabated. (author)

  18. New Challenges in Contamination Control: The Leadership Role ofIEST in Shaping Future Research and Practices.

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Tengfang; Eudy, Jane; Berndt, Charles

    2007-01-01

    develop, revise, and publish new documents at a faster pace than had been seen in recent decades. For example, eight updated revisions of existing or brand new RPs have been published since 2005 (marked as yellow), and approximately seven more RPs and RDs are well positioned in the pipeline for official publication by early 2007 (marked as green). Due to their quality and timeliness, many IEST RPs are primary references and sources of information for compliance with the ISO 14644 series of International Standards developed by ISO Technical Committee (ISO/TC) 209, Cleanrooms and associated controlled environments. Additionally, IEST conducts technical seminars, workshops, and tutorials at its annual technical meeting (ESTECH), its Fall Conference, and online to assist related industries to better understand the 'state-of-the art' philosophies and effectively utilize IEST Recommended Practices and ISO Standards. Being the leading organization and a voting member of the ANSI-accredited US Technical Advisory Group (TAG) to ISO/TC 229, Nanotechnologies, IEST is in a unique position to contribute its expertise in developing international standards for controlled environments to anticipate the unique needs of the emerging nanoscience/nanotechnology industry. For example, the IEST has formulated a new program to address the complex issues relevant to all industries working in this area and includes nanoparticles, other relevant contamination control 2 issues, and building facilities to conduct research and produce products related to nanotechnology. Leading industry experts in this area have been gathering at IEST conferences since the Fall Conference in 2005 and are working diligently on a first-ever industry road map and subsequent RPs the IEST Recommended Practices NANO200 series. The first document titled 'Planning, Design, Construction & Operations Considerations for Facilities Engaged in Research or Production at the Nanometer Scale' is, as mentioned

  19. A Novel Coordinated Control of Renewable Energy Sources and Energy Storage System in Islanded Microgrid

    DEFF Research Database (Denmark)

    Gui, Yonghao; Li, Mingshen; Guerrero, Josep M.

    2018-01-01

    A novel coordinated control for energy storage system (ESS) and renewable energy source (RES) units is proposed in islanded AC microgrids without a phase-locked loop system. We use a proportional-resonant control technique for the ESS, which fixes the voltage and frequency of the microgrid...

  20. Regularized inversion of controlled source and earthquake data

    International Nuclear Information System (INIS)

    Ramachandran, Kumar

    2012-01-01

    Estimation of the seismic velocity structure of the Earth's crust and upper mantle from travel-time data has advanced greatly in recent years. Forward modelling trial-and-error methods have been superseded by tomographic methods which allow more objective analysis of large two-dimensional and three-dimensional refraction and/or reflection data sets. The fundamental purpose of travel-time tomography is to determine the velocity structure of a medium by analysing the time it takes for a wave generated at a source point within the medium to arrive at a distribution of receiver points. Tomographic inversion of first-arrival travel-time data is a nonlinear problem since both the velocity of the medium and ray paths in the medium are unknown. The solution for such a problem is typically obtained by repeated application of linearized inversion. Regularization of the nonlinear problem reduces the ill posedness inherent in the tomographic inversion due to the under-determined nature of the problem and the inconsistencies in the observed data. This paper discusses the theory of regularized inversion for joint inversion of controlled source and earthquake data, and results from synthetic data testing and application to real data. The results obtained from tomographic inversion of synthetic data and real data from the northern Cascadia subduction zone show that the velocity model and hypocentral parameters can be efficiently estimated using this approach. (paper)