WorldWideScience

Sample records for solution procedure simple

  1. Robust and efficient solution procedures for association models

    DEFF Research Database (Denmark)

    Michelsen, Michael Locht

    2006-01-01

    Equations of state that incorporate the Wertheim association expression are more difficult to apply than conventional pressure explicit equations, because the association term is implicit and requires solution for an internal set of composition variables. In this work, we analyze the convergence...... behavior of different solution methods and demonstrate how a simple and efficient, yet globally convergent, procedure for the solution of the equation of state can be formulated....

  2. Simple and reliable procedure for the evaluation of short-term dynamic processes in power systems

    Energy Technology Data Exchange (ETDEWEB)

    Popovic, D P

    1986-10-01

    An efficient approach is presented to the solution of the short-term dynamics model in power systems. It consists of an adequate algebraic treatment of the original system of nonlinear differential equations, using linearization, decomposition and Cauchy's formula. The simple difference equations obtained in this way are incorporated into a model of the electrical network, which is of a low order compared to the ones usually used. Newton's method is applied to the model formed in this way, which leads to a simple and reliable iterative procedure. The characteristics of the procedure developed are demonstrated on examples of transient stability analysis of real power systems. 12 refs.

  3. Simple Solutions for Dry Eye

    Science.gov (United States)

    Patient Education Sheet Simple Solutions for Dry Eye The SSF thanks J. Daniel Nelson, MD, Associate Medical Director, Specialty Care HealthPartners Medical Group & Clinics, and Professor of Ophthalmology, University of ...

  4. Solution of a simple inelastic scattering problem

    International Nuclear Information System (INIS)

    Knudson, S.K.

    1975-01-01

    Simple examples of elastic scattering, typically from square wells, serve as important pedagogical tools in discussion of the concepts and processes involved in elastic scattering events. An analytic solution of a model inelastic scattering system is presented here to serve in this role for inelastic events. The model and its solution are simple enough to be of pedagogical utility, but also retain enough of the important physical features to include most of the special characteristics of inelastic systems. The specific model chosen is the collision of an atom with a harmonic oscillator, interacting via a repulsive square well potential. Pedagogically important features of inelastic scattering, including its multistate character, convergence behavior, and dependence on an ''inelastic potential'' are emphasized as the solution is determined. Results are presented for various energies and strengths of inelastic scattering, which show that the model is capable of providing an elementary representation of vibrationally inelastic scattering

  5. A simple approach to nonlinear oscillators

    International Nuclear Information System (INIS)

    Ren Zhongfu; He Jihuan

    2009-01-01

    A very simple and effective approach to nonlinear oscillators is suggested. Anyone with basic knowledge of advanced calculus can apply the method to finding approximately the amplitude-frequency relationship of a nonlinear oscillator. Some examples are given to illustrate its extremely simple solution procedure and an acceptable accuracy of the obtained solutions.

  6. Inverse kinematic solution for near-simple robots and its application to robot calibration

    Science.gov (United States)

    Hayati, Samad A.; Roston, Gerald P.

    1986-01-01

    This paper provides an inverse kinematic solution for a class of robot manipulators called near-simple manipulators. The kinematics of these manipulators differ from those of simple-robots by small parameter variations. Although most robots are by design simple, in practice, due to manufacturing tolerances, every robot is near-simple. The method in this paper gives an approximate inverse kinematics solution for real time applications based on the nominal solution for these robots. The validity of the results are tested both by a simulation study and by applying the algorithm to a PUMA robot.

  7. Manga Vectorization and Manipulation with Procedural Simple Screentone.

    Science.gov (United States)

    Yao, Chih-Yuan; Hung, Shih-Hsuan; Li, Guo-Wei; Chen, I-Yu; Adhitya, Reza; Lai, Yu-Chi

    2017-02-01

    Manga are a popular artistic form around the world, and artists use simple line drawing and screentone to create all kinds of interesting productions. Vectorization is helpful to digitally reproduce these elements for proper content and intention delivery on electronic devices. Therefore, this study aims at transforming scanned Manga to a vector representation for interactive manipulation and real-time rendering with arbitrary resolution. Our system first decomposes the patch into rough Manga elements including possible borders and shading regions using adaptive binarization and screentone detector. We classify detected screentone into simple and complex patterns: our system extracts simple screentone properties for refining screentone borders, estimating lighting, compensating missing strokes inside screentone regions, and later resolution independently rendering with our procedural shaders. Our system treats the others as complex screentone areas and vectorizes them with our proposed line tracer which aims at locating boundaries of all shading regions and polishing all shading borders with the curve-based Gaussian refiner. A user can lay down simple scribbles to cluster Manga elements intuitively for the formation of semantic components, and our system vectorizes these components into shading meshes along with embedded Bézier curves as a unified foundation for consistent manipulation including pattern manipulation, deformation, and lighting addition. Our system can real-time and resolution independently render the shading regions with our procedural shaders and drawing borders with the curve-based shader. For Manga manipulation, the proposed vector representation can be not only magnified without artifacts but also deformed easily to generate interesting results.

  8. Solving Simple Kinetics without Integrals

    Science.gov (United States)

    de la Pen~a, Lisandro Herna´ndez

    2016-01-01

    The solution of simple kinetic equations is analyzed without referencing any topic from differential equations or integral calculus. Guided by the physical meaning of the rate equation, a systematic procedure is used to generate an approximate solution that converges uniformly to the exact solution in the case of zero, first, and second order…

  9. Trigonometric solutions of triangle equations. Simple Lie superalgebras

    International Nuclear Information System (INIS)

    Bazhanov, V.V.; Shadrikov, A.G.

    1988-01-01

    Trigonometric solutions of the graded triangle equation are constructed for the fundamental representations of all simple (nonexceptional) Lie superalgebras with nondegenerate metric. In Sec. 1, we introduce the concept of Z 2 graded spaces and give the basic definitions. In Sec. 2, we determine fundamental representations of the Lie superalgebras sl(mn) and osp(2rs) and give explicit realizations of the Coxeter automorphisms. In secs. 3 and 4, we give the trigonometric solutions of the graded triangle equation (quantum R matrices)

  10. A Simple Solution to Type Specialization

    DEFF Research Database (Denmark)

    Danvy, Olivier

    1998-01-01

    Partial evaluation specializes terms, but traditionally this specialization does not apply to the type of these terms. As a result, specializing, e.g., an interpreter written in a typed language, which requires a “universal” type to encode expressible values, yields residual programs with type tags...... all over. Neil Jones has stated that getting rid of these type tags was an open problem, despite possible solutions such as Torben Mogensen's “constructor specialization.” To solve this problem, John Hughes has proposed a new paradigm for partial evaluation, “Type Specialization”, based on type...... inference instead of being based on symbolic interpretation. Type Specialization is very elegant in principle but it also appears non-trivial in practice. Stating the problem in terms of types instead of in terms of type encodings suggests a very simple type-directed solution, namely, to use a projection...

  11. A Simple Method for Identifying the Acromioclavicular Joint During Arthroscopic Procedures

    OpenAIRE

    Javed, Saqib; Heasley, Richard; Ravenscroft, Matt

    2013-01-01

    Arthroscopic acromioclavicular joint excision is performed via an anterior portal and is technically demanding. We present a simple method for identifying the acromioclavicular joint during arthroscopic procedures.

  12. A Rapid Selection Procedure for Simple Commercial Implementation of omega-Transaminase Reactions

    DEFF Research Database (Denmark)

    Gundersen Deslauriers, Maria; Tufvesson, Pär; Rackham, Emma J.

    2016-01-01

    A stepwise selection procedure is presented to quickly evaluate whether a given omega-transaminase reaction is suitable for a so-called "simple" scale-up for fast industrial implementation. Here "simple" is defined as a system without the need for extensive process development or specialized......, and (3) determination of product inhibition. The method is exemplified with experimental work focused on two products: 1-(4-bromophenyl)ethylamine and (S)-(+)3-amino-1-Boc-piperidine, synthesized from their corresponding pro-chiral ketones each with two alternative amine donors, propan-2-amine, and 1......-phenylethylamine. Each step of the method has a threshold value, which must be surpassed to allow "simple" implementation, helping select suitable combinations of substrates, enzymes, and donors. One reaction pair, 1-Boc-3-piperidone with propan-2-amine, met the criteria of the three-step selection procedure...

  13. About simple nonlinear and linear superpositions of special exact solutions of Veselov-Novikov equation

    International Nuclear Information System (INIS)

    Dubrovsky, V. G.; Topovsky, A. V.

    2013-01-01

    New exact solutions, nonstationary and stationary, of Veselov-Novikov (VN) equation in the forms of simple nonlinear and linear superpositions of arbitrary number N of exact special solutions u (n) , n= 1, …, N are constructed via Zakharov and Manakov ∂-dressing method. Simple nonlinear superpositions are represented up to a constant by the sums of solutions u (n) and calculated by ∂-dressing on nonzero energy level of the first auxiliary linear problem, i.e., 2D stationary Schrödinger equation. It is remarkable that in the zero energy limit simple nonlinear superpositions convert to linear ones in the form of the sums of special solutions u (n) . It is shown that the sums u=u (k 1 ) +...+u (k m ) , 1 ⩽k 1 2 m ⩽N of arbitrary subsets of these solutions are also exact solutions of VN equation. The presented exact solutions include as superpositions of special line solitons and also superpositions of plane wave type singular periodic solutions. By construction these exact solutions represent also new exact transparent potentials of 2D stationary Schrödinger equation and can serve as model potentials for electrons in planar structures of modern electronics.

  14. Two simple ansaetze for obtaining exact solutions of high dispersive nonlinear Schroedinger equations

    International Nuclear Information System (INIS)

    Palacios, Sergio L.

    2004-01-01

    We propose two simple ansaetze that allow us to obtain different analytical solutions of the high dispersive cubic and cubic-quintic nonlinear Schroedinger equations. Among these solutions we can find solitary wave and periodic wave solutions representing the propagation of different waveforms in nonlinear media

  15. About simple nonlinear and linear superpositions of special exact solutions of Veselov-Novikov equation

    Energy Technology Data Exchange (ETDEWEB)

    Dubrovsky, V. G.; Topovsky, A. V. [Novosibirsk State Technical University, Karl Marx prosp. 20, Novosibirsk 630092 (Russian Federation)

    2013-03-15

    New exact solutions, nonstationary and stationary, of Veselov-Novikov (VN) equation in the forms of simple nonlinear and linear superpositions of arbitrary number N of exact special solutions u{sup (n)}, n= 1, Horizontal-Ellipsis , N are constructed via Zakharov and Manakov {partial_derivative}-dressing method. Simple nonlinear superpositions are represented up to a constant by the sums of solutions u{sup (n)} and calculated by {partial_derivative}-dressing on nonzero energy level of the first auxiliary linear problem, i.e., 2D stationary Schroedinger equation. It is remarkable that in the zero energy limit simple nonlinear superpositions convert to linear ones in the form of the sums of special solutions u{sup (n)}. It is shown that the sums u=u{sup (k{sub 1})}+...+u{sup (k{sub m})}, 1 Less-Than-Or-Slanted-Equal-To k{sub 1} < k{sub 2} < Horizontal-Ellipsis < k{sub m} Less-Than-Or-Slanted-Equal-To N of arbitrary subsets of these solutions are also exact solutions of VN equation. The presented exact solutions include as superpositions of special line solitons and also superpositions of plane wave type singular periodic solutions. By construction these exact solutions represent also new exact transparent potentials of 2D stationary Schroedinger equation and can serve as model potentials for electrons in planar structures of modern electronics.

  16. The simple procedure for the fluxgate magnetometers calibration

    Science.gov (United States)

    Marusenkov, Andriy

    2014-05-01

    The fluxgate magnetometers are widely used in geophysics investigations including the geomagnetic field monitoring at the global network of geomagnetic observatories as well as for electromagnetic sounding of the Earth's crust conductivity. For solving these tasks the magnetometers have to be calibrated with an appropriate level of accuracy. As a particular case, the ways to satisfy the recent requirements to the scaling and orientation errors of 1-second INTERNAGNET magnetometers are considered in the work. The goal of the present study was to choose a simple and reliable calibration method for estimation of scale factors and angular errors of the three-axis magnetometers in the field. There are a large number of the scalar calibration methods, which use a free rotation of the sensor in the calibration field followed by complicated data processing procedures for numerical solution of the high-order equations set. The chosen approach also exploits the Earth's magnetic field as a calibrating signal, but, in contrast to other methods, the sensor has to be oriented in some particular positions in respect to the total field vector, instead of the sensor free rotation. This allows to use very simple and straightforward linear computation formulas and, as a result, to achieve more reliable estimations of the calibrated parameters. The estimation of the scale factors is performed by the sequential aligning of each component of the sensor in two positions: parallel and anti-parallel to the Earth's magnetic field vector. The estimation of non-orthogonality angles between each pair of components is performed after sequential aligning of the components at the angles +/- 45 and +/- 135 degrees of arc in respect to the total field vector. Due to such four positions approach the estimations of the non-orthogonality angles are invariant to the zero offsets and non-linearity of transfer functions of the components. The experimental justifying of the proposed method by means of the

  17. A Simple General Solution for Maximal Horizontal Range of Projectile Motion

    OpenAIRE

    Busic, Boris

    2005-01-01

    A convenient change of variables in the problem of maximizing the horizontal range of the projectile motion, with an arbitrary initial vertical position of the projectile, provides a simple, straightforward solution.

  18. New family of simple solutions of relativistic perfect fluid hydrodynamics

    International Nuclear Information System (INIS)

    Csoergo, T.; Nagy, M.I.; Csanad, M.

    2008-01-01

    A new class of accelerating, exact and explicit solutions of relativistic hydrodynamics is found-more than 50 years after the previous similar result, the Landau-Khalatnikov solution. Surprisingly, the new solutions have a simple form, that generalizes the renowned, but accelerationless, Hwa-Bjorken solution. These new solutions take into account the work done by the fluid elements on each other, and work not only in one temporal and one spatial dimensions, but also in arbitrary number of spatial dimensions. They are applied here for an advanced estimation of initial energy density and life-time of the reaction in ultra-relativistic heavy ion collisions. New formulas are also conjectured, that yield further important increase of the initial energy density estimate and the measured life-time of the reaction if the value of the speed of sound is in the realistic range

  19. Computationally simple, analytic, closed form solution of the Coulomb self-interaction problem in Kohn Sham density functional theory

    International Nuclear Information System (INIS)

    Gonis, Antonios; Daene, Markus W.; Nicholson, Don M.; Stocks, George Malcolm

    2012-01-01

    We have developed and tested in terms of atomic calculations an exact, analytic and computationally simple procedure for determining the functional derivative of the exchange energy with respect to the density in the implementation of the Kohn Sham formulation of density functional theory (KS-DFT), providing an analytic, closed-form solution of the self-interaction problem in KS-DFT. We demonstrate the efficacy of our method through ground-state calculations of the exchange potential and energy for atomic He and Be atoms, and comparisons with experiment and the results obtained within the optimized effective potential (OEP) method.

  20. A simple, flexible and efficient PCR-fusion/Gateway cloning procedure for gene fusion, site-directed mutagenesis, short sequence insertion and domain deletions and swaps

    Directory of Open Access Journals (Sweden)

    Etchells J Peter

    2009-10-01

    Full Text Available Abstract Background The progress and completion of various plant genome sequencing projects has paved the way for diverse functional genomic studies that involve cloning, modification and subsequent expression of target genes. This requires flexible and efficient procedures for generating binary vectors containing: gene fusions, variants from site-directed mutagenesis, addition of protein tags together with domain swaps and deletions. Furthermore, efficient cloning procedures, ideally high throughput, are essential for pyramiding of multiple gene constructs. Results Here, we present a simple, flexible and efficient PCR-fusion/Gateway cloning procedure for construction of binary vectors for a range of gene fusions or variants with single or multiple nucleotide substitutions, short sequence insertions, domain deletions and swaps. Results from selected applications of the procedure which include ORF fusion, introduction of Cys>Ser mutations, insertion of StrepII tag sequence and domain swaps for Arabidopsis secondary cell wall AtCesA genes are demonstrated. Conclusion The PCR-fusion/Gateway cloning procedure described provides an elegant, simple and efficient solution for a wide range of diverse and complicated cloning tasks. Through streamlined cloning of sets of gene fusions and modification variants into binary vectors for systematic functional studies of gene families, our method allows for efficient utilization of the growing sequence and expression data.

  1. Asymptotic shape of solutions to the perturbed simple pendulum problems

    Directory of Open Access Journals (Sweden)

    Tetsutaro Shibata

    2007-05-01

    Full Text Available We consider the positive solution of the perturbed simple pendulum problem $$ u''(r + frac{N-1}{r}u'(r - g(u(t + lambda sin u(r = 0, $$ with $0 < r < R$, $ u'(0 = u(R = 0$. To understand well the shape of the solution $u_lambda$ when $lambda gg 1$, we establish the leading and second terms of $Vert u_lambdaVert_q$ ($1 le q < infty$ with the estimate of third term as $lambda o infty$. We also obtain the asymptotic formula for $u_lambda'(R$ as $lambda o infty$.

  2. A simple procedure for the purification of active fractions in aqueous extracts of plants with allelopathic properties

    Directory of Open Access Journals (Sweden)

    Fabian Borghetti

    2013-03-01

    Full Text Available Most studies conducted to test the allelopathic activity of plant parts have made use of water as solvent. However, the presence of polar, water-soluble substances, such as proteins and carbohydrates, tends to hamper the purification of active compounds. In this study, we present a simple purification procedure that separates the active fraction of the extract from the undesirable substances, thus facilitating the search for active molecules through standard chromatographic methods. Aqueous leaf extracts of three Cerrado species (Caryocar brasiliense, Qualea parviflora and Eugenia dysenterica were prepared at 5% concentration (w/v and stored at 4ºC (crude extracts. After 24 h, these solutions were filtered and freeze-dried. The powder obtained was dissolved in methanol, filtered again, evaporated and dissolved in water for bioassays (purified extracts. For the bioassays, seedlings of Sesamum indicum were grown for five days in aqueous solutions prepared from crude and purified extracts at concentrations ranging from 0.1% to 1.0% (w/v. Seedling growth in distilled water was set as a control. In comparison with the control, we found that test solutions prepared from both crude and purified extracts significantly inhibited sesame seedling growth. However, solutions prepared from purified extracts were two to ten times more inhibitory to seedling growth than were those prepared from crude extracts. The inhibition of root growth ranged from 35% to 77%, depending on the plant species, at a concentration as low as 0.1%. Roots were more affected than were shoots. The effects of purified extracts on seedling morphology were similar to those observed when crude extracts were employed, indicating that the procedure of purification of crude extracts did not interfere with the mode of action of the active substances

  3. A computational procedure for finding multiple solutions of convective heat transfer equations

    International Nuclear Information System (INIS)

    Mishra, S; DebRoy, T

    2005-01-01

    In recent years numerical solutions of the convective heat transfer equations have provided significant insight into the complex materials processing operations. However, these computational methods suffer from two major shortcomings. First, these procedures are designed to calculate temperature fields and cooling rates as output and the unidirectional structure of these solutions preclude specification of these variables as input even when their desired values are known. Second, and more important, these procedures cannot determine multiple pathways or multiple sets of input variables to achieve a particular output from the convective heat transfer equations. Here we propose a new method that overcomes the aforementioned shortcomings of the commonly used solutions of the convective heat transfer equations. The procedure combines the conventional numerical solution methods with a real number based genetic algorithm (GA) to achieve bi-directionality, i.e. the ability to calculate the required input variables to achieve a specific output such as temperature field or cooling rate. More important, the ability of the GA to find a population of solutions enables this procedure to search for and find multiple sets of input variables, all of which can lead to the desired specific output. The proposed computational procedure has been applied to convective heat transfer in a liquid layer locally heated on its free surface by an electric arc, where various sets of input variables are computed to achieve a specific fusion zone geometry defined by an equilibrium temperature. Good agreement is achieved between the model predictions and the independent experimental results, indicating significant promise for the application of this procedure in finding multiple solutions of convective heat transfer equations

  4. A simple but accurate procedure for solving the five-parameter model

    International Nuclear Information System (INIS)

    Mares, Oana; Paulescu, Marius; Badescu, Viorel

    2015-01-01

    Highlights: • A new procedure for extracting the parameters of the one-diode model is proposed. • Only the basic information listed in the datasheet of PV modules are required. • Results demonstrate a simple, robust and accurate procedure. - Abstract: The current–voltage characteristic of a photovoltaic module is typically evaluated by using a model based on the solar cell equivalent circuit. The complexity of the procedure applied for extracting the model parameters depends on data available in manufacture’s datasheet. Since the datasheet is not detailed enough, simplified models have to be used in many cases. This paper proposes a new procedure for extracting the parameters of the one-diode model in standard test conditions, using only the basic data listed by all manufactures in datasheet (short circuit current, open circuit voltage and maximum power point). The procedure is validated by using manufacturers’ data for six commercially crystalline silicon photovoltaic modules. Comparing the computed and measured current–voltage characteristics the determination coefficient is in the range 0.976–0.998. Thus, the proposed procedure represents a feasible tool for solving the five-parameter model applied to crystalline silicon photovoltaic modules. The procedure is described in detail, to guide potential users to derive similar models for other types of photovoltaic modules.

  5. Simple and Accurate Analytical Solutions of the Electrostatically Actuated Curled Beam Problem

    KAUST Repository

    Younis, Mohammad I.

    2014-01-01

    We present analytical solutions of the electrostatically actuated initially deformed cantilever beam problem. We use a continuous Euler-Bernoulli beam model combined with a single-mode Galerkin approximation. We derive simple analytical expressions

  6. Polarographic behaviour and determination of selenite and tellurite in simple solutions or in a binary mixture

    International Nuclear Information System (INIS)

    Hassan, A.

    1991-01-01

    The polarographic behaviour of simple solutions of selenite and tellurite in 1 M ammonium salts of formate, acetate, tartrate, oxalate, and benzoate solutions in absence and in presence of Triton X-100 as a maximum suppressor and a temperature of 25 O C has been investigated. Schemes for the mechanism of reductions occuring at the DME have been deduced. A method for analytical determination of selenite and tellurite in simple solutions as well as in a binary mixture in the presence of 4-14 . 10 -3 % Triton X-100 is reported. (author)

  7. The stationary sine-Gordon equation on metric graphs: Exact analytical solutions for simple topologies

    Science.gov (United States)

    Sabirov, K.; Rakhmanov, S.; Matrasulov, D.; Susanto, H.

    2018-04-01

    We consider the stationary sine-Gordon equation on metric graphs with simple topologies. Exact analytical solutions are obtained for different vertex boundary conditions. It is shown that the method can be extended for tree and other simple graph topologies. Applications of the obtained results to branched planar Josephson junctions and Josephson junctions with tricrystal boundaries are discussed.

  8. Anion bridges drive salting out of a simple amphiphile from aqueous solution

    International Nuclear Information System (INIS)

    Bowron, D.T.; Finney, J.L.

    2002-01-01

    Neutron diffraction with isotope substitution has been used to determine the structural changes that occur on the addition of a simple salting-out agent to a dilute aqueous alcohol solution. The striking results obtained demonstrate a relatively simple process occurs in which interamphiphile anionic salt bridges are formed between the polar groups of the alcohol molecules. These ion bridges drive an increase in the exposure of the alcohol molecule nonpolar surface to the solvent water and hence point the way to their eventual salting out by the hydrophobic effect

  9. "Compacted" procedures for adults' simple addition: A review and critique of the evidence.

    Science.gov (United States)

    Chen, Yalin; Campbell, Jamie I D

    2018-04-01

    We review recent empirical findings and arguments proffered as evidence that educated adults solve elementary addition problems (3 + 2, 4 + 1) using so-called compacted procedures (e.g., unconscious, automatic counting); a conclusion that could have significant pedagogical implications. We begin with the large-sample experiment reported by Uittenhove, Thevenot and Barrouillet (2016, Cognition, 146, 289-303), which tested 90 adults on the 81 single-digit addition problems from 1 + 1 to 9 + 9. They identified the 12 very-small addition problems with different operands both ≤ 4 (e.g., 4 + 3) as a distinct subgroup of problems solved by unconscious, automatic counting: These items yielded a near-perfectly linear increase in answer response time (RT) yoked to the sum of the operands. Using the data reported in the article, however, we show that there are clear violations of the sum-counting model's predictions among the very-small addition problems, and that there is no real RT boundary associated with addends ≤4. Furthermore, we show that a well-known associative retrieval model of addition facts-the network interference theory (Campbell, 1995)-predicts the results observed for these problems with high precision. We also review the other types of evidence adduced for the compacted procedure theory of simple addition and conclude that these findings are unconvincing in their own right and only distantly consistent with automatic counting. We conclude that the cumulative evidence for fast compacted procedures for adults' simple addition does not justify revision of the long-standing assumption that direct memory retrieval is ultimately the most efficient process of simple addition for nonzero problems, let alone sufficient to recommend significant changes to basic addition pedagogy.

  10. Simple Machines Forum, a Solution for Dialogue Optimization between Physicians

    Directory of Open Access Journals (Sweden)

    Laura SÎNGIORZAN

    2013-02-01

    Full Text Available We developed an instrument which can ensure a quick and easy dialogue between the physicians of the Oncology Institute and family physicians. The platform we chose was Simple Machines Forum (abbreviated as SMF, a free Internet forum (BBS - Bulletin Board System application. The purpose of this article is not to detail the software platform, but to emphasize the facilities and advantages of using this solution in the medical community.

  11. Simple solution-processed titanium oxide electron transport layer for efficient inverted polymer solar cells

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Liang [CAS Key Laboratory of Bio-based Materials, Qingdao Institute of Bioenergy and Bioprocess Technology, Chinese Academy of Sciences, Qingdao 266101 (China); University of Chinese Academy of Sciences, Beijing 100049 (China); Shen, Wenfei [CAS Key Laboratory of Bio-based Materials, Qingdao Institute of Bioenergy and Bioprocess Technology, Chinese Academy of Sciences, Qingdao 266101 (China); Institute of Hybrid Materials, Laboratory of New Fiber Materials and Modern Textile—The Growing Base for State Key Laboratory, Qingdao University, Qingdao 266071 (China); Chen, Weichao [CAS Key Laboratory of Bio-based Materials, Qingdao Institute of Bioenergy and Bioprocess Technology, Chinese Academy of Sciences, Qingdao 266101 (China); Bao, Xichang, E-mail: baoxc@qibebt.ac.cn [CAS Key Laboratory of Bio-based Materials, Qingdao Institute of Bioenergy and Bioprocess Technology, Chinese Academy of Sciences, Qingdao 266101 (China); Wang, Ning; Dou, Xiaowei; Han, Liangliang; Wen, Shuguang [CAS Key Laboratory of Bio-based Materials, Qingdao Institute of Bioenergy and Bioprocess Technology, Chinese Academy of Sciences, Qingdao 266101 (China)

    2014-12-31

    Titanium oxide (TiO{sub X}) is an effective electron transport layer (ETL) in polymer solar cells (PSCs). We report efficient inverted PSCs with a simple solution-processed amorphous TiO{sub X} (s-TiO{sub X}) film as an ETL. The s-TiO{sub X} film with high light transmittance was prepared by spin-coating titanium (IV) isopropoxide isopropanol solution on indium tin oxide coated glass in inert and then placed in air under room temperature for 60 min. The introduction of s-TiO{sub X} ETL greatly improved the short circuit current density of the devices. PSCs based on poly(3-hexylthiophene):[6,6]-phenyl-C61-butyric acid methyl ester and poly(4,8-bis-alkyloxy-benzo[1,2-b:4,5-b′]dithiophene-alt-alkylcarbonyl -thieno[3,4-b]thiophene):[6,6]-phenyl- C71-butyric acid methyl ester using s-TiO{sub X} film as ETL shows high power conversion efficiency of 4.29% and 6.7% under the illumination of AM 1.5G, 100 mW/cm{sup 2}, which shows enhancements compared to the conventional PSCs with poly(styrenesulfonate)-doped poly(ethylenedioxythiophene) as anode buffer layer. In addition, the device exhibits good stability in a humid ambient atmosphere without capsulation. The results indicate that the annealing-free, simple solution processed s-TiO{sub X} film is an efficient ETL for high-performance PSCs. - Highlights: • High quality s-TiO{sub X} films were prepared by a simple, solution method without thermal treatment. • The s-TiO{sub X} films with high transmittance are very smooth. • The organic photovoltaic performance with s-TiO{sub X} film improved greatly and exhibited good stability. • The annealing-free, simple prepared s-TiO{sub X} film will be much compatible with flexible substrates.

  12. A Two Stage Solution Procedure for Production Planning System with Advance Demand Information

    Science.gov (United States)

    Ueno, Nobuyuki; Kadomoto, Kiyotaka; Hasuike, Takashi; Okuhara, Koji

    We model for ‘Naiji System’ which is a unique corporation technique between a manufacturer and suppliers in Japan. We propose a two stage solution procedure for a production planning problem with advance demand information, which is called ‘Naiji’. Under demand uncertainty, this model is formulated as a nonlinear stochastic programming problem which minimizes the sum of production cost and inventory holding cost subject to a probabilistic constraint and some linear production constraints. By the convexity and the special structure of correlation matrix in the problem where inventory for different periods is not independent, we propose a solution procedure with two stages which are named Mass Customization Production Planning & Management System (MCPS) and Variable Mesh Neighborhood Search (VMNS) based on meta-heuristics. It is shown that the proposed solution procedure is available to get a near optimal solution efficiently and practical for making a good master production schedule in the suppliers.

  13. Procedures for accurately diluting and dispensing radioactive solutions

    International Nuclear Information System (INIS)

    1975-01-01

    The technique currently used by various laboratories participating in international comparisons of radioactivity measurements are surveyed and recommendations for good laboratory practice established. Thus one describes, for instance, the preparation of solutions, dilution techniques, the use of 'pycnometers', weighing procedures (including buyoancy correction), etc. It should be possible to keep random and systematic uncertainties below 0.1% of the final result

  14. Simple and accurate solution for convective-radiative fin with temperature dependent thermal conductivity using double optimal linearization

    International Nuclear Information System (INIS)

    Bouaziz, M.N.; Aziz, Abdul

    2010-01-01

    A novel concept of double optimal linearization is introduced and used to obtain a simple and accurate solution for the temperature distribution in a straight rectangular convective-radiative fin with temperature dependent thermal conductivity. The solution is built from the classical solution for a pure convection fin of constant thermal conductivity which appears in terms of hyperbolic functions. When compared with the direct numerical solution, the double optimally linearized solution is found to be accurate within 4% for a range of radiation-conduction and thermal conductivity parameters that are likely to be encountered in practice. The present solution is simple and offers superior accuracy compared with the fairly complex approximate solutions based on the homotopy perturbation method, variational iteration method, and the double series regular perturbation method. The fin efficiency expression resembles the classical result for the constant thermal conductivity convecting fin. The present results are easily usable by the practicing engineers in their thermal design and analysis work involving fins.

  15. A simple method for validation and verification of pipettes mounted on automated liquid handlers

    DEFF Research Database (Denmark)

    Stangegaard, Michael; Hansen, Anders Johannes; Frøslev, Tobias G

    2011-01-01

    We have implemented a simple, inexpensive, and fast procedure for validation and verification of the performance of pipettes mounted on automated liquid handlers (ALHs) as necessary for laboratories accredited under ISO 17025. A six- or seven-step serial dilution of OrangeG was prepared in quadru......We have implemented a simple, inexpensive, and fast procedure for validation and verification of the performance of pipettes mounted on automated liquid handlers (ALHs) as necessary for laboratories accredited under ISO 17025. A six- or seven-step serial dilution of OrangeG was prepared...... are freely available. In conclusion, we have set up a simple, inexpensive, and fast solution for the continuous validation of ALHs used for accredited work according to the ISO 17025 standard. The method is easy to use for aqueous solutions but requires a spectrophotometer that can read microtiter plates....

  16. A simple procedure for measuring pharyngeal sensitivity: a contribution to the diagnosis of sleep apnoea

    OpenAIRE

    Dematteis, M; Levy, P; Pepin, J

    2005-01-01

    Background: Patients with severe apnoea may have an impaired pharyngeal dilating reflex related to decreased pharyngeal sensitivity. The accuracy of a simple new procedure to measure pharyngeal sensitivity and to diagnose sleep disordered breathing (SDB) was investigated.

  17. Vitrification of human ovarian tissue: effect of different solutions and procedures.

    Science.gov (United States)

    Amorim, Christiani Andrade; David, Anu; Van Langendonckt, Anne; Dolmans, Marie-Madeleine; Donnez, Jacques

    2011-03-01

    To test the effect of different vitrification solutions and procedures on the morphology of human preantral follicles. Pilot study. Gynecology research unit in a university hospital. Ovarian biopsies were obtained from nine women aged 22-35 years. Ovarian tissue fragments were subjected to [1] different vitrification solutions to test their toxicity or [2] different vitrification methods using plastic straws, medium droplets, or solid-surface vitrification before in vitro culture. Number of morphologically normal follicles after toxicity testing or vitrification with the different treatments determined by histologic analysis. In the toxicity tests, only VS3 showed similar results to fresh tissue before and after in vitro culture (fresh controls 1 and 2). In addition, this was the only solution able to completely vitrify. In all vitrification procedures, the percentage of normal follicles was lower than in controls. However, of the three protocols, the droplet method yielded a significantly higher proportion of normal follicles. Our experiments showed VS3 to have no deleterious effect on follicular morphology and to be able to completely vitrify, although vitrification procedures were found to affect human follicles. Nevertheless, the droplet method resulted in a higher percentage of morphologically normal follicles. Copyright © 2011 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.

  18. On flux integrals for generalized Melvin solution related to simple finite-dimensional Lie algebra

    Energy Technology Data Exchange (ETDEWEB)

    Ivashchuk, V.D. [VNIIMS, Center for Gravitation and Fundamental Metrology, Moscow (Russian Federation); Peoples' Friendship University of Russia (RUDN University), Institute of Gravitation and Cosmology, Moscow (Russian Federation)

    2017-10-15

    A generalized Melvin solution for an arbitrary simple finite-dimensional Lie algebra G is considered. The solution contains a metric, n Abelian 2-forms and n scalar fields, where n is the rank of G. It is governed by a set of n moduli functions H{sub s}(z) obeying n ordinary differential equations with certain boundary conditions imposed. It was conjectured earlier that these functions should be polynomials - the so-called fluxbrane polynomials. These polynomials depend upon integration constants q{sub s}, s = 1,.., n. In the case when the conjecture on the polynomial structure for the Lie algebra G is satisfied, it is proved that 2-form flux integrals Φ{sup s} over a proper 2d submanifold are finite and obey the relations q{sub s} Φ{sup s} = 4πn{sub s}h{sub s}, where the h{sub s} > 0 are certain constants (related to dilatonic coupling vectors) and the n{sub s} are powers of the polynomials, which are components of a twice dual Weyl vector in the basis of simple (co-)roots, s = 1,.., n. The main relations of the paper are valid for a solution corresponding to a finite-dimensional semi-simple Lie algebra G. Examples of polynomials and fluxes for the Lie algebras A{sub 1}, A{sub 2}, A{sub 3}, C{sub 2}, G{sub 2} and A{sub 1} + A{sub 1} are presented. (orig.)

  19. Contribution of the ''simple solutions'' concept to estimate density of actinides concentrated solutions

    International Nuclear Information System (INIS)

    Sorel, C.; Moisy, Ph.; Dinh, B.; Blanc, P.

    2000-01-01

    In order to calculate criticality parameters of nuclear fuel solution systems, number density of nuclides are needed and they are generally estimated from density equations. Most of the relations allowing the calculation of the density of aqueous solutions containing the electrolytes HNO 3 -UO 2 (NO 3 ) 2 -Pu(NO 3 ) 4 , usually called 'nitrate dilution laws' are strictly empirical. They are obtained from a fit of assumed polynomial expressions on experimental density data. Out of their interpolation range, such mathematical expressions show discrepancies between calculated and experimental data appearing in the high concentrations range. In this study, a physico-chemical approach based on the isopiestic mixtures rule is suggested. The behaviour followed by these mixtures was first observed in 1936 by Zdanovskii and expressed as: 'Binary solutions (i.e. one electrolyte in water) having a same water activity are mixed without variation of this water activity value'. With regards to this behaviour, a set of basic thermodynamic expressions has been pointed out by Ryazanov and Vdovenko in 1965 concerning enthalpy, entropy, volume of mixtures, activity and osmotic coefficient of the components. In particular, a very simple relation for the density is obtained from the volume mixture expression depending on only two physico-chemical variables: i) concentration of each component in the mixture and in their respectively binary solutions having the same water activity as the mixture and ii), density of each component respectively in the binary solution having the same water activity as the mixture. Therefore, the calculation needs the knowledge of binary data (water activity, density and concentration) of each component at the same temperature as the mixture. Such experimental data are largely published in the literature and are available for nitric acid and uranyl nitrate. Nevertheless, nitric acid binary data show large discrepancies between the authors and need to be

  20. Simple and Efficient Procedure for Synthesis of N'-Arylamidines Using Trimethylaluminum

    International Nuclear Information System (INIS)

    Korbad, Balaji L.; Lee, Sanghyeup

    2013-01-01

    In conclusion, we have developed simple and efficient procedure for the synthesis of N'-arylamidines using tri-methylaluminum, nitriles and aryl amines under mild condition. Aliphatic, aromatic nitriles were reacted well with a variety of aromatic amine to afford corresponding amidines in good to high yields. Amidines are an important class of compounds that have wide range of application in the fields of catalyst design, material science, medicinal chemistry and also shown the promising anti-inflammatory and analgesic activity. They are valuable synthons for synthesis of various heterocyclic compounds. In addition, recent studies have demonstrated their capacity to fix carbon dioxide

  1. Simple thermodynamic model of the extension of solid solution of Cu-Mo alloys processed by mechanical alloying

    International Nuclear Information System (INIS)

    Aguilar, C.; Guzman, D.; Rojas, P.A.; Ordonez, Stella; Rios, R.

    2011-01-01

    Highlights: → Extension of solid solution in Cu-Mo systems achieved by mechanical alloying. → Simple thermodynamic model to explain extension of solid solution of Mo in Cu. → Model gives results that are consistent with the solubility limit extension reported in other works. - Abstract: The objective of this work is proposing a simple thermodynamic model to explain the increase in the solubility limit of the powders of the Cu-Mo systems or other binary systems processed by mechanical alloying. In the regular solution model, the effects of crystalline defects, such as; dislocations and grain boundary produced during milling were introduced. The model gives results that are consistent with the solubility limit extension reported in other works for the Cu-Cr, Cu-Nb and Cu-Fe systems processed by mechanical alloying.

  2. Catheter for Cleaning Surgical Optics During Surgical Procedures: A Possible Solution for Residue Buildup and Fogging in Video Surgery.

    Science.gov (United States)

    de Abreu, Igor Renato Louro Bruno; Abrão, Fernando Conrado; Silva, Alessandra Rodrigues; Corrêa, Larissa Teresa Cirera; Younes, Riad Nain

    2015-05-01

    Currently, there is a tendency to perform surgical procedures via laparoscopic or thoracoscopic access. However, even with the impressive technological advancement in surgical materials, such as improvement in quality of monitors, light sources, and optical fibers, surgeons have to face simple problems that can greatly hinder surgery by video. One is the formation of "fog" or residue buildup on the lens, causing decreased visibility. Intracavitary techniques for cleaning surgical optics and preventing fog formation have been described; however, some of these techniques employ the use of expensive and complex devices designed solely for this purpose. Moreover, these techniques allow the cleaning of surgical optics when they becomes dirty, which does not prevent the accumulation of residue in the optics. To solve this problem we have designed a device that allows cleaning the optics with no surgical stops and prevents the fogging and residue accumulation. The objective of this study is to evaluate through experimental testing the effectiveness of a simple device that prevents the accumulation of residue and fogging of optics used in surgical procedures performed through thoracoscopic or laparoscopic access. Ex-vivo experiments were performed simulating the conditions of residue presence in surgical optics during a video surgery. The experiment consists in immersing the optics and catheter set connected to the IV line with crystalloid solution in three types of materials: blood, blood plus fat solution, and 200 mL of distilled water and 1 vial of methylene blue. The optics coupled to the device were immersed in 200 mL of each type of residue, repeating each immersion 10 times for each distinct residue for both thirty and zero degrees optics, totaling 420 experiments. A success rate of 98.1% was observed after the experiments, in these cases the device was able to clean and prevent the residue accumulation in the optics.

  3. Continuously variable rating: a new, simple and logical procedure to evaluate original scientific publications

    Directory of Open Access Journals (Sweden)

    Mauricio Rocha e Silva

    2011-01-01

    Full Text Available OBJECTIVE: Impact Factors (IF are widely used surrogates to evaluate single articles, in spite of known shortcomings imposed by cite distribution skewness. We quantify this asymmetry and propose a simple computer-based procedure for evaluating individual articles. METHOD: (a Analysis of symmetry. Journals clustered around nine Impact Factor points were selected from the medical ‘‘Subject Categories’’ in Journal Citation Reports 2010. Citable items published in 2008 were retrieved and ranked by granted citations over the Jan/2008 - Jun/2011 period. Frequency distribution of cites, normalized cumulative cites and absolute cites/decile were determined for each journal cluster. (b Positive Predictive Value. Three arbitrarily established evaluation classes were generated: LOW (1.33.9. Positive Predictive Value for journal clusters within each class range was estimated. (c Continuously Variable Rating. An alternative evaluation procedure is proposed to allow the rating of individually published articles in comparison to all articles published in the same journal within the same year of publication. The general guiding lines for the construction of a totally dedicated software program are delineated. RESULTS AND CONCLUSIONS: Skewness followed the Pareto Distribution for (1simple computer based procedure capable of accurately providing a valid rating for each article within the journal and time frame in which it was published.

  4. A simple approximative procedure for taking into account low cycle fatigue loads

    Energy Technology Data Exchange (ETDEWEB)

    Larsen, G; Thomsen, K

    1996-09-01

    In this paper a simple approximative algorithm for taking into account low cycle fatigue loads is presented. Traditionally, the fatigue life consumption of a wind turbine is estimated by considering a number of (independent) load cases and performing a rainflow counting analysis on each of those. These results are then subsequently synthesized into a total load spectrum by performing a weighed sum of the number of individual load case ranges. The fatigue life consumption is thus obtained by applying the Palmgren-Miner rule on the total load spectrum. However, due to the assumption of isolated basic load cases, the above procedure fail to represent the low-frequency contributions related to the transition between those load cases. The procedure to be described in the following aims at taking the fatigue contribution, related to the transitions between the defined load cases, into account in an approximative manner. (au)

  5. Simple solution-processed CuOX as anode buffer layer for efficient organic solar cells

    International Nuclear Information System (INIS)

    Shen, Wenfei; Yang, Chunpeng; Bao, Xichang; Sun, Liang; Wang, Ning; Tang, Jianguo; Chen, Weichao; Yang, Renqiang

    2015-01-01

    Graphical abstract: - Highlights: • Simple solution-processed CuO X hole transport layer for efficient organic solar cell. • Good photovoltaic performances as hole transport layer in OSCs with P3HT and PBDTTT-C as donor materials. • The device with CuO X as hole transport layer shows great improved stability compared with that of device with PEDOT:PSS as hole transport layer. - Abstract: A simple, solution-processed ultrathin CuO X anode buffer layer was fabricated for high performance organic solar cells (OSCs). XPS measurement demonstrated that the CuO X was the composite of CuO and Cu 2 O. The CuO X modified ITO glass exhibit a better surface contact with the active layer. The photovoltaic performance of the devices with CuO X layer was optimized by varying the thickness of CuO X films through changing solution concentration. With P3HT:PC 61 BM as the active layer, we demonstrated an enhanced PCE of 4.14% with CuO X anode buffer layer, compared with that of PEDOT:PSS layer. The CuO X layer also exhibits efficient photovoltaic performance in devices with PBDTTT-C:PC 71 BM as the active layer. The long-term stability of CuO X device is better than that of PEDOT:PSS device. The results indicate that the easy solution-processed CuO X film can act as an efficient anode buffer layer for high-efficiency OSCs

  6. Robotic general surgery experience: a gradual progress from simple to more complex procedures.

    Science.gov (United States)

    Al-Naami, M; Anjum, M N; Aldohayan, A; Al-Khayal, K; Alkharji, H

    2013-12-01

    Robotic surgery was introduced at our institution in 2003, and we used a progressive approach advancing from simple to more complex procedures. A retrospective chart review. Cases included totalled 129. Set-up and operative times have improved over time and with experience. Conversion rates to standard laparoscopic or open techniques were 4.7% and 1.6%, respectively. Intraoperative complications (6.2%), blood loss and hospital stay were directly proportional to complexity. There were no mortalities and the postoperative complication rate (13.2%) was within accepted norms. Our findings suggest that robot technology is presently most useful in cases tailored toward its advantages, i.e. those confined to a single space, those that require performance of complex tasks, and re-do procedures. Copyright © 2013 John Wiley & Sons, Ltd.

  7. Combined LAURA-UPS solution procedure for chemically-reacting flows. M.S. Thesis

    Science.gov (United States)

    Wood, William A.

    1994-01-01

    A new procedure seeks to combine the thin-layer Navier-Stokes solver LAURA with the parabolized Navier-Stokes solver UPS for the aerothermodynamic solution of chemically-reacting air flowfields. The interface protocol is presented and the method is applied to two slender, blunted shapes. Both axisymmetric and three dimensional solutions are included with surface pressure and heat transfer comparisons between the present method and previously published results. The case of Mach 25 flow over an axisymmetric six degree sphere-cone with a noncatalytic wall is considered to 100 nose radii. A stability bound on the marching step size was observed with this case and is attributed to chemistry effects resulting from the noncatalytic wall boundary condition. A second case with Mach 28 flow over a sphere-cone-cylinder-flare configuration is computed at both two and five degree angles of attack with a fully-catalytic wall. Surface pressures are seen to be within five percent with the present method compared to the baseline LAURA solution and heat transfers are within 10 percent. The effect of grid resolution is investigated and the nonequilibrium results are compared with a perfect gas solution, showing that while the surface pressure is relatively unchanged by the inclusion of reacting chemistry the nonequilibrium heating is 25 percent higher. The procedure demonstrates significant, order of magnitude reductions in solution time and required memory for the three dimensional case over an all thin-layer Navier-Stokes solution.

  8. Water-Reflected 233U Uranyl Nitrate Solutions in Simple Geometry

    International Nuclear Information System (INIS)

    Elam, K.R.

    2001-01-01

    A number of critical experiments involving 233 U were performed in the Oak Ridge National Laboratory Building 9213 Critical Experiments Facility during the years 1952 and 1953. These experiments, reported in Reference 1, were directed toward determining bounding values for the minimum critical mass, minimum critical volume, and maximum safe pipe size of water-moderated solutions of 233 U. Additional information on the critical experiments was found in the experimental logbooks. Two experiments utilizing uranyl nitrate (UO 2 (NO 3 ) 2 ) solutions in simple geometry are evaluated in this report. Experiment 37 is in a 10.4-inch diameter sphere, and Experiment 39 is in a 10-inch diameter cylinder. The 233 U concentration ranges from 49 to 62 g 233 U/l. Both experiments were reflected by at least 6 inches of water in all directions. Paraffin-reflected uranyl nitrate experiments, also reported in Reference 1, are evaluated elsewhere. Experiments with smaller paraffin reflected 5-, 6-, and 7.5-inch diameter cylinders are evaluated in U233-SOL-THERM-004. Experiments with paraffin reflected 8-, 8.5-, 9-, 10-, and 12-inch diameter cylinders are evaluated in U233-SOL-THERM-002. Later experiments with highly-enriched 235 U uranyl fluoride solution in the same 10.4-inch diameter sphere are reported in HEU-SOL-THERM-010. Both experiments were judged acceptable for use as criticality-safety benchmark experiments

  9. Simple and effective procedure for conformational search of macromolecules. Application to Met- and Leu-Enkephalin

    Energy Technology Data Exchange (ETDEWEB)

    Meirovitch, H.; Meirovitch, E. (Florida State Univ., Tallahassee, FL (United States)); Michel, A.G. (Institut de Recherches Serrier, Suresnes (France)); Vasquez, M. (Protein Design Lab., Mountain View, CA (United States))

    1994-06-23

    A simple and efficient method for searching the conformational space of macromolecules is presented. With this method an initial set of relatively low-energy structures is generated, and their energies are further minimized with a procedure that enables escaping from local energy minima. Illustrative calculations are described for Met- and Leu-enkephalin. 37 refs., 1 tab.

  10. A simple and effective solution to the constrained QM/MM simulations

    Science.gov (United States)

    Takahashi, Hideaki; Kambe, Hiroyuki; Morita, Akihiro

    2018-04-01

    It is a promising extension of the quantum mechanical/molecular mechanical (QM/MM) approach to incorporate the solvent molecules surrounding the QM solute into the QM region to ensure the adequate description of the electronic polarization of the solute. However, the solvent molecules in the QM region inevitably diffuse into the MM bulk during the QM/MM simulation. In this article, we developed a simple and efficient method, referred to as the "boundary constraint with correction (BCC)," to prevent the diffusion of the solvent water molecules by means of a constraint potential. The point of the BCC method is to compensate the error in a statistical property due to the bias potential by adding a correction term obtained through a set of QM/MM simulations. The BCC method is designed so that the effect of the bias potential completely vanishes when the QM solvent is identical with the MM solvent. Furthermore, the desirable conditions, that is, the continuities of energy and force and the conservations of energy and momentum, are fulfilled in principle. We applied the QM/MM-BCC method to a hydronium ion(H3O+) in aqueous solution to construct the radial distribution function (RDF) of the solvent around the solute. It was demonstrated that the correction term fairly compensated the error and led the RDF in good agreement with the result given by an ab initio molecular dynamics simulation.

  11. A Simple Approach to Derive a Novel N-Soliton Solution for a (3+1)-Dimensional Nonlinear Evolution Equation

    International Nuclear Information System (INIS)

    Wu Jianping

    2010-01-01

    Based on the Hirota bilinear form, a simple approach without employing the standard perturbation technique, is presented for constructing a novel N-soliton solution for a (3+1)-dimensional nonlinear evolution equation. Moreover, the novel N-soliton solution is shown to have resonant behavior with the aid of Mathematica. (general)

  12. Data harmonization of environmental variables: from simple to general solutions

    Science.gov (United States)

    Baume, O.

    2009-04-01

    European data platforms often contain measurements from different regional or national networks. As standards and protocols - e.g. type of measurement devices, sensors or measurement site classification, laboratory analysis and post-processing methods, vary between networks, discontinuities will appear when mapping the target variable at an international scale. Standardisation is generally a costly solution and does not allow classical statistical analysis of previously reported values. As an alternative, harmonization should be envisaged as an integrated step in mapping procedures across borders. In this paper, several harmonization solutions developed under the INTAMAP FP6 project are presented. The INTAMAP FP6 project is currently developing an interoperable framework for real-time automatic mapping of critical environmental variables by extending spatial statistical methods to web-based implementations. Harmonization is often considered as a pre-processing step in statistical data analysis workflow. If biases are assessed with little knowledge about the target variable - in particular when no explanatory covariate is integrated, a harmonization procedure along borders or between regionally overlapping networks may be adopted (Skøien et al., 2007). In this case, bias is estimated as the systematic difference between line or local predictions. On the other hand, when covariates can be included in spatial prediction, the harmonization step is integrated in the whole model estimation procedure, and, therefore, is no longer an independent pre-processing step of the automatic mapping process (Baume et al., 2007). In this case, bias factors become integrated parameters of the geostatistical model and are estimated alongside the other model parameters. The harmonization methods developed within the INTAMAP project were first applied within the field of radiation, where the European Radiological Data Exchange Platform (EURDEP) - http://eurdep.jrc.ec.europa.eu/ - has

  13. Simple and fast orotracheal intubation procedure in rats.

    Science.gov (United States)

    Tomasello, Giovanni; Damiani, Francesco; Cassata, Giovanni; Palumbo, Vincenzo Davide; Sinagra, Emanuele; Damiani, Provvidenza; Bruno, Antonino; Cicero, Luca; Cupido, Francesco; Carini, Francesco; Lo Monte, Attilio Ignazio

    2016-05-06

    Endotracheal intubation in the rat is difficult because of the extremely small size of anatomical structures (oral cavity, epiglottis and vocal cords), small inlet for an endotracheal tube and the lack of proper technical instruments. In this study we used seventy rats weighting 400-500 g. The equipment needed for the intubation was an operating table, a longish of cotton, a cotton tip, orotracheal tube, neonatal laryngoscope blades, KTR4 small animal ventilator and isoflurane for inhalation anaesthesia. Premedication was carried out by medetomidine hydrochloride 1 mg/mL; then, thanks to a closed glass chamber, a mixture of oxygen and isoflurane was administered. By means of a neonatal laryngoscope the orotracheal tube was advanced into the oral cavity until the wire guide was visualized trough the vocal cords; then it was passed through them. The tube was introduced directly into the larynx over the wire guide; successively, the guide was removed and the tube placed into the trachea. Breathing was confirmed using a glove, cut at the end of a finger, simulating a small balloon. We achieved a fast and simple orotracheal intubation in all animals employed. We believe that our procedure is easier and faster than those previously reported in scientific literature.

  14. Low Cost, Simple, Intrauterine Insemination Procedure

    African Journals Online (AJOL)

    AJRH Managing Editor

    quite simple intrauterine insemination technique which may be performed in developing countries, without the need of sophisticated ... Cytoplasmic Sperm Injection (ICSI), are quite ... were administered only once by intramuscular injection ...

  15. The simple solutions concept: a useful approach to estimate deviation from ideality in solvent extraction

    International Nuclear Information System (INIS)

    Sorel, C.; Pacary, V.

    2010-01-01

    The solvent extraction systems devoted to uranium purification from crude ore to spent fuel involve concentrated solutions in which deviation from ideality can not be neglected. The Simple Solution Concept based on the behaviour of isopiestic solutions has been applied to quantify the activity coefficients of metals and acids in the aqueous phase in equilibrium with the organic phase. This approach has been validated on various solvent extraction systems such as trialkylphosphates, malonamides or acidic extracting agents both on batch experiments and counter-current tests. Moreover, this concept has been successfully used to estimate the aqueous density which is useful to quantify the variation of volume and to assess critical parameters such as the number density of nuclides. (author)

  16. Photographic paper X-ray procedure - a simple technique for the visualisation of osseous norm variations and malformations

    International Nuclear Information System (INIS)

    Markert, K.; Wirth, I.; Reinhold-Richter, L.

    1983-01-01

    On the basis of osseous norm variations and malformations, a simple X-ray procedure by means of photographic paper which can be applied in every institute of pathology is demonstrated. The quality of the photographs permits the assessment of skeletal changes which are of diagnostic importance. (author)

  17. A simple and cheap system to speed up and to control the tumescent technique procedure: the Tedde's system.

    Science.gov (United States)

    Rubino, C; Marongiu, F; Manzo, M J; Tedde, G; Madonia, M; Campus, G V; Farace, F

    2014-06-01

    We have devised a low cost system to quickly infiltrate tumescent solution: we call it the "Tedde's system". This low-cost system offers an improvement in quality and quantity of the infiltration because all the procedure depends on the operators, reducing also the time of the infiltration and consequently of the whole surgical procedure. Moreover, this system can be applied to other surgical procedure that requires large infiltration volumes.

  18. Renormalization group equation and scaling solutions for f(R) gravity in exponential parametrization

    International Nuclear Information System (INIS)

    Ohta, Nobuyoshi; Percacci, Roberto; Vacca, Gian Paolo

    2016-01-01

    We employ the exponential parametrization of the metric and a ''physical'' gauge fixing procedure to write a functional flow equation for the gravitational effective average action in an f(R) truncation. The background metric is a four-sphere and the coarse-graining procedure contains three free parameters. We look for scaling solutions, i.e. non-Gaussian fixed points for the function f. For a discrete set of values of the parameters, we find simple global solutions of quadratic polynomial form. For other values, global solutions can be found numerically. Such solutions can be extended in certain regions of parameter space and have two relevant directions. We discuss the merits and the shortcomings of this procedure. (orig.)

  19. Evaluation of solution procedures for material and/or geometrically nonlinear structural analysis by the direct stiffness method.

    Science.gov (United States)

    Stricklin, J. A.; Haisler, W. E.; Von Riesemann, W. A.

    1972-01-01

    This paper presents an assessment of the solution procedures available for the analysis of inelastic and/or large deflection structural behavior. A literature survey is given which summarized the contribution of other researchers in the analysis of structural problems exhibiting material nonlinearities and combined geometric-material nonlinearities. Attention is focused at evaluating the available computation and solution techniques. Each of the solution techniques is developed from a common equation of equilibrium in terms of pseudo forces. The solution procedures are applied to circular plates and shells of revolution in an attempt to compare and evaluate each with respect to computational accuracy, economy, and efficiency. Based on the numerical studies, observations and comments are made with regard to the accuracy and economy of each solution technique.

  20. Analytical solution for the electrical properties of a radio-frequency quadrupole (RFQ) with simple vanes

    International Nuclear Information System (INIS)

    Lancaster, H.

    1982-01-01

    Although the SUPERFISH program is used for calculating the design parameters of an RFQ structure with complex vanes, an analytical solution for electrical properties of an RFQ with simple vanes provides insight into the parametric behavior of these more complicated resonators. The fields in an inclined plane wave guide with proper boundary conditions match those in one quadrant of an RFQ. The principle of duality is used to exploit the solutions to a radial transmission line in solving the field equations. Calculated are the frequency equation, frequency sensitivity factors, electric field, magnetic field, stored energy (U), power dissipation, and quality factor

  1. An efficient algorithm for computation of solitary wave solutions to ...

    Indian Academy of Sciences (India)

    KAMRAN AYUB

    2017-09-08

    Sep 8, 2017 ... solutions has attracted lots of attention by scientists in the field of nonlinear science ... The procedure of this technique is quite simple, explicit, and can easily be extended ... divided into different sections. In the next section, we.

  2. A simple procedure for retrieval of a cement-retained implant-supported crown: a case report.

    Science.gov (United States)

    Buzayan, Muaiyed Mahmoud; Mahmood, Wan Adida; Yunus, Norsiah Binti

    2014-02-01

    Retrieval of cement-retained implant prostheses can be more demanding than retrieval of screw-retained prostheses. This case report describes a simple and predictable procedure to locate the abutment screw access openings of cementretained implant-supported crowns in cases of fractured ceramic veneer. A conventional periapical radiography image was captured using a digital camera, transferred to a computer, and manipulated using Microsoft Word document software to estimate the location of the abutment screw access.

  3. Excess Gibbs energy for six binary solid solutions of molecularly simple substances

    Energy Technology Data Exchange (ETDEWEB)

    Lobo, L J; Staveley, L A.K.

    1985-01-01

    In this paper we apply the method developed in a previous study of Ar + CH/sub 4/ to the evaluation of the excess Gibbs energy G /SUP E.S/ for solid solutions of two molecularly simple components. The method depends on combining information on the excess Gibbs energy G /SUP E.L/ for the liquid mixture of the two components with a knowledge of the (T, x) solid-liquid phase diagram. Certain thermal properties o the pure substances are also needed. G /SUP E.S/ has been calculated for binary mixtures of Ar + Kr, Kr + CH/sub 4/, CO + N/sub 2/, Kr + Xe, Ar + N/sub 2/, and Ar + CO. In general, but not always, the solid mixtures are more non-ideal than the liquid mixtures of the same composition at the same temperature. Except for the Kr + CH/sub 4/ system, the ratio r = G /SUP E.S/ /G /SUP E.L/ is larger the richer the solution in the component with the smaller molecules.

  4. Baryon string model. II. Special solutions of classical three-string equations of motion

    International Nuclear Information System (INIS)

    Klimenko, S.V.; Kochin, V.N.; Plyushchai, M.S.; Pron'ko, G.P.

    1986-01-01

    The authors consider special solutions of the classical threestring equations of motion. The basic results needed for construction and analysis of the special solutions are examined. The authors consider very simple solutions in which the three-string node moves with the velocity of light. Singlemode solutions are studied. The graphical packet Atom is used to study and visualize the string dynamics. A new procedure was developed within the packet for graphical representation of many parameter functions. The distinctive feature of these procedures is the large class of functions (including explicit, implicit, and parametric functions) that can be represented by means of parametric, coordinate, and functional isolines

  5. Rapid and simple clean-up and derivatizaton procedure for the gas chromatographic determination of acidic drugs in plasma

    NARCIS (Netherlands)

    Roseboom, H.; Hulshoff, A.

    1979-01-01

    A rapid and simple clean-up and derivatization procedure that can be generally applied to the gas chromatographie (GC) determination of acidic drugs of various chemical and therapeutic classes is described. The drugs are extracted from acidified plasma with chloroform containing 5% of isopropanol,

  6. Solutions of simple dual bootstrap models satisfying Lee--Veneziano relation and the smallness of cut discontinuities

    International Nuclear Information System (INIS)

    Chiu, C.B.; Hossain, M.; Tow, D.M.

    1977-07-01

    To investigate the t-dependent solutions of simple dual bootstrap models, two general formulations are discussed, one without and one with cut cancellation at the planar level. The possible corresponding production mechanisms are discussed. In contrast to Bishari's formulation, both models recover the Lee-Veneziano relation, i.e., in the peak approximation the Pomeron intercept is unity. The solutions based on an exponential form for the reduced triple-Reggeon vertex for both models are discussed in detail. Also calculated are the cut discontinuities for both models and for Bishari's and it is shown that at both the planar and cylinder levels they are small compared with the corresponding pole residues. Precocious asymptotic planarity is also found in the solutions

  7. Simple electrolyte solutions: Comparison of DRISM and molecular dynamics results for alkali halide solutions

    Science.gov (United States)

    Joung, In Suk; Luchko, Tyler; Case, David A.

    2013-01-01

    Using the dielectrically consistent reference interaction site model (DRISM) of molecular solvation, we have calculated structural and thermodynamic information of alkali-halide salts in aqueous solution, as a function of salt concentration. The impact of varying the closure relation used with DRISM is investigated using the partial series expansion of order-n (PSE-n) family of closures, which includes the commonly used hypernetted-chain equation (HNC) and Kovalenko-Hirata closures. Results are compared to explicit molecular dynamics (MD) simulations, using the same force fields, and to experiment. The mean activity coefficients of ions predicted by DRISM agree well with experimental values at concentrations below 0.5 m, especially when using the HNC closure. As individual ion activities (and the corresponding solvation free energies) are not known from experiment, only DRISM and MD results are directly compared and found to have reasonably good agreement. The activity of water directly estimated from DRISM is nearly consistent with values derived from the DRISM ion activities and the Gibbs-Duhem equation, but the changes in the computed pressure as a function of salt concentration dominate these comparisons. Good agreement with experiment is obtained if these pressure changes are ignored. Radial distribution functions of NaCl solution at three concentrations were compared between DRISM and MD simulations. DRISM shows comparable water distribution around the cation, but water structures around the anion deviate from the MD results; this may also be related to the high pressure of the system. Despite some problems, DRISM-PSE-n is an effective tool for investigating thermodynamic properties of simple electrolytes. PMID:23387564

  8. Efficient electroluminescence from a perylenediimide fluorophore obtained from a simple solution processed OLED

    International Nuclear Information System (INIS)

    Cespedes-Guirao, F J; Fernandez-Lazaro, F; Sastre-Santos, A; Garcia-Santamaria, S; Bolink, H J

    2009-01-01

    Simple solution processed organic light emitting diodes are used to screen the performance of two types of highly efficient, narrow band red emitting fluorescent perylenediimides (PDIs). PDIs substituted at the diimide positions seem to form aggregates in the thin film architecture as evidenced by the shifted electroluminescent spectrum. When substituted on the bay position and when used both as the emitting and the electron transporting specie, bright electroluminescence with a narrow width around 610 nm reaching 500 cd m -2 at moderate voltages was observed, demonstrating the usefulness of these fluorophores for OLED applications.

  9. CFD code verification and the method of manufactured solutions

    International Nuclear Information System (INIS)

    Pelletier, D.; Roache, P.J.

    2002-01-01

    This paper presents the Method of Manufactured Solutions (MMS) for CFD code verification. The MMS provides benchmark solutions for direct evaluation of the solution error. The best benchmarks are exact analytical solutions with sufficiently complex solution structure to ensure that all terms of the differential equations are exercised in the simulation. The MMS provides a straight forward and general procedure for generating such solutions. When used with systematic grid refinement studies, which are remarkably sensitive, the MMS provides strong code verification with a theorem-like quality. The MMS is first presented on simple 1-D examples. Manufactured solutions for more complex problems are then presented with sample results from grid convergence studies. (author)

  10. Simple solution-processed CuO{sub X} as anode buffer layer for efficient organic solar cells

    Energy Technology Data Exchange (ETDEWEB)

    Shen, Wenfei [CAS Key Laboratory of Bio-based Materials, Qingdao Institute of Bioenergy and Bioprocess Technology, Chinese Academy of Sciences, 189 Songling Road, Qingdao 266101 (China); Institute of Hybrid Materials, The Growing Base for State Key Laboratory, Qingdao University, 308 Ningxia Road, Qingdao 266071 (China); Yang, Chunpeng [CAS Key Laboratory of Bio-based Materials, Qingdao Institute of Bioenergy and Bioprocess Technology, Chinese Academy of Sciences, 189 Songling Road, Qingdao 266101 (China); Bao, Xichang, E-mail: baoxc@qibebt.ac.cn [CAS Key Laboratory of Bio-based Materials, Qingdao Institute of Bioenergy and Bioprocess Technology, Chinese Academy of Sciences, 189 Songling Road, Qingdao 266101 (China); Sun, Liang; Wang, Ning [CAS Key Laboratory of Bio-based Materials, Qingdao Institute of Bioenergy and Bioprocess Technology, Chinese Academy of Sciences, 189 Songling Road, Qingdao 266101 (China); Tang, Jianguo [Institute of Hybrid Materials, The Growing Base for State Key Laboratory, Qingdao University, 308 Ningxia Road, Qingdao 266071 (China); Chen, Weichao [CAS Key Laboratory of Bio-based Materials, Qingdao Institute of Bioenergy and Bioprocess Technology, Chinese Academy of Sciences, 189 Songling Road, Qingdao 266101 (China); Yang, Renqiang, E-mail: yangrq@qibebt.ac.cn [CAS Key Laboratory of Bio-based Materials, Qingdao Institute of Bioenergy and Bioprocess Technology, Chinese Academy of Sciences, 189 Songling Road, Qingdao 266101 (China)

    2015-10-15

    Graphical abstract: - Highlights: • Simple solution-processed CuO{sub X} hole transport layer for efficient organic solar cell. • Good photovoltaic performances as hole transport layer in OSCs with P3HT and PBDTTT-C as donor materials. • The device with CuO{sub X} as hole transport layer shows great improved stability compared with that of device with PEDOT:PSS as hole transport layer. - Abstract: A simple, solution-processed ultrathin CuO{sub X} anode buffer layer was fabricated for high performance organic solar cells (OSCs). XPS measurement demonstrated that the CuO{sub X} was the composite of CuO and Cu{sub 2}O. The CuO{sub X} modified ITO glass exhibit a better surface contact with the active layer. The photovoltaic performance of the devices with CuO{sub X} layer was optimized by varying the thickness of CuO{sub X} films through changing solution concentration. With P3HT:PC{sub 61}BM as the active layer, we demonstrated an enhanced PCE of 4.14% with CuO{sub X} anode buffer layer, compared with that of PEDOT:PSS layer. The CuO{sub X} layer also exhibits efficient photovoltaic performance in devices with PBDTTT-C:PC{sub 71}BM as the active layer. The long-term stability of CuO{sub X} device is better than that of PEDOT:PSS device. The results indicate that the easy solution-processed CuO{sub X} film can act as an efficient anode buffer layer for high-efficiency OSCs.

  11. Simple Ion Transfer at Liquid|Liquid Interfaces

    Directory of Open Access Journals (Sweden)

    L. J. Sanchez Vallejo

    2012-01-01

    Full Text Available The main aspects related to the charge transfer reactions occurring at the interface between two immiscible electrolyte solutions (ITIES are described. The particular topics to be discussed involve simple ion transfer. Focus is given on theoretical approaches, numerical simulations, and experimental methodologies. Concerning the theoretical procedures, different computational simulations related to simple ion transfer are reviewed. The main conclusions drawn from the most accepted models are described and analyzed in regard to their relevance for explaining different aspects of ion transfer. We describe numerical simulations implementing different approaches for solving the differential equations associated with the mass transport and charge transfer. These numerical simulations are correlated with selected experimental results; their usefulness in designing new experiments is summarized. Finally, many practical applications can be envisaged regarding the determination of physicochemical properties, electroanalysis, drug lipophilicity, and phase-transfer catalysis.

  12. Solute transport along a single fracture in a porous rock: a simple analytical solution and its extension for modeling velocity dispersion

    Science.gov (United States)

    Liu, Longcheng; Neretnieks, Ivars; Shahkarami, Pirouz; Meng, Shuo; Moreno, Luis

    2018-02-01

    A simple and robust solution is developed for the problem of solute transport along a single fracture in a porous rock. The solution is referred to as the solution to the single-flow-path model and takes the form of a convolution of two functions. The first function is the probability density function of residence-time distribution of a conservative solute in the fracture-only system as if the rock matrix is impermeable. The second function is the response of the fracture-matrix system to the input source when Fickian-type dispersion is completely neglected; thus, the effects of Fickian-type dispersion and matrix diffusion have been decoupled. It is also found that the solution can be understood in a way in line with the concept of velocity dispersion in fractured rocks. The solution is therefore extended into more general cases to also account for velocity variation between the channels. This leads to a development of the multi-channel model followed by detailed statistical descriptions of channel properties and sensitivity analysis of the model upon changes in the model key parameters. The simulation results obtained by the multi-channel model in this study fairly well agree with what is often observed in field experiments—i.e. the unchanged Peclet number with distance, which cannot be predicted by the classical advection-dispersion equation. In light of the findings from the aforementioned analysis, it is suggested that forced-gradient experiments can result in considerably different estimates of dispersivity compared to what can be found in natural-gradient systems for typical channel widths.

  13. Prediction of thermodynamic instabilities of protein solutions from simple protein–protein interactions

    International Nuclear Information System (INIS)

    D’Agostino, Tommaso; Solana, José Ramón; Emanuele, Antonio

    2013-01-01

    Highlights: ► We propose a model of effective protein–protein interaction embedding solvent effects. ► A previous square-well model is enhanced by giving to the interaction a free energy character. ► The temperature dependence of the interaction is due to entropic effects of the solvent. ► The validity of the original SW model is extended to entropy driven phase transitions. ► We get good fits for lysozyme and haemoglobin spinodal data taken from literature. - Abstract: Statistical thermodynamics of protein solutions is often studied in terms of simple, microscopic models of particles interacting via pairwise potentials. Such modelling can reproduce the short range structure of protein solutions at equilibrium and predict thermodynamics instabilities of these systems. We introduce a square well model of effective protein–protein interaction that embeds the solvent’s action. We modify an existing model [45] by considering a well depth having an explicit dependence on temperature, i.e. an explicit free energy character, thus encompassing the statistically relevant configurations of solvent molecules around proteins. We choose protein solutions exhibiting demixing upon temperature decrease (lysozyme, enthalpy driven) and upon temperature increase (haemoglobin, entropy driven). We obtain satisfactory fits of spinodal curves for both the two proteins without adding any mean field term, thus extending the validity of the original model. Our results underline the solvent role in modulating or stretching the interaction potential

  14. Acylation of Chiral Alcohols: A Simple Procedure for Chiral GC Analysis

    Directory of Open Access Journals (Sweden)

    Mireia Oromí-Farrús

    2012-01-01

    Full Text Available The use of iodine as a catalyst and either acetic or trifluoroacetic acid as a derivatizing reagent for determining the enantiomeric composition of acyclic and cyclic aliphatic chiral alcohols was investigated. Optimal conditions were selected according to the molar ratio of alcohol to acid, the reaction time, and the reaction temperature. Afterwards, chiral stability of chiral carbons was studied. Although no isomerization was observed when acetic acid was used, partial isomerization was detected with the trifluoroacetic acid. A series of chiral alcohols of a widely varying structural type were then derivatized with acetic acid using the optimal conditions. The resolution of the enantiomeric esters and the free chiral alcohols was measured using a capillary gas chromatograph equipped with a CP Chirasil-DEX CB column. The best resolutions were obtained with 2-pentyl acetates (α=3.00 and 2-hexyl acetates (α=1.95. This method provides a very simple and efficient experimental workup procedure for analyzing chiral alcohols by chiral-phase GC.

  15. Acylation of Chiral Alcohols: A Simple Procedure for Chiral GC Analysis.

    Science.gov (United States)

    Oromí-Farrús, Mireia; Torres, Mercè; Canela, Ramon

    2012-01-01

    The use of iodine as a catalyst and either acetic or trifluoroacetic acid as a derivatizing reagent for determining the enantiomeric composition of acyclic and cyclic aliphatic chiral alcohols was investigated. Optimal conditions were selected according to the molar ratio of alcohol to acid, the reaction time, and the reaction temperature. Afterwards, chiral stability of chiral carbons was studied. Although no isomerization was observed when acetic acid was used, partial isomerization was detected with the trifluoroacetic acid. A series of chiral alcohols of a widely varying structural type were then derivatized with acetic acid using the optimal conditions. The resolution of the enantiomeric esters and the free chiral alcohols was measured using a capillary gas chromatograph equipped with a CP Chirasil-DEX CB column. The best resolutions were obtained with 2-pentyl acetates (α = 3.00) and 2-hexyl acetates (α = 1.95). This method provides a very simple and efficient experimental workup procedure for analyzing chiral alcohols by chiral-phase GC.

  16. Addressing challenges in single species assessments via a simple state-space assessment model

    DEFF Research Database (Denmark)

    Nielsen, Anders

    Single-species and age-structured fish stock assessments still remains the main tool for managing fish stocks. A simple state-space assessment model is presented as an alternative to (semi) deterministic procedures and the full parametric statistical catch at age models. It offers a solution...... to some of the key challenges of these models. Compared to the deterministic procedures it solves a list of problems originating from falsely assuming that age classified catches are known without errors and allows quantification of uncertainties of estimated quantities of interest. Compared to full...

  17. A Differential Quadrature Procedure with Regularization of the Dirac-delta Function for Numerical Solution of Moving Load Problem

    Directory of Open Access Journals (Sweden)

    S. A. Eftekhari

    Full Text Available AbstractThe differential quadrature method (DQM is one of the most elegant and efficient methods for the numerical solution of partial differential equations arising in engineering and applied sciences. It is simple to use and also straightforward to implement. However, the DQM is well-known to have some difficulty when applied to partial differential equations involving singular functions like the Dirac-delta function. This is caused by the fact that the Dirac-delta function cannot be directly discretized by the DQM. To overcome this difficulty, this paper presents a simple differential quadrature procedure in which the Dirac-delta function is replaced by regularized smooth functions. By regularizing the Dirac-delta function, such singular function is treated as non-singular functions and can be easily and directly discretized using the DQM. To demonstrate the applicability and reliability of the proposed method, it is applied here to solve some moving load problems of beams and rectangular plates, where the location of the moving load is described by a time-dependent Dirac-delta function. The results generated by the proposed method are compared with analytical and numerical results available in the literature. Numerical results reveal that the proposed method can be used as an efficient tool for dynamic analysis of beam- and plate-type structures traversed by moving dynamic loads.

  18. A recommended procedure for estimating the cosmic-ray spectral parameter of a simple power law

    CERN Document Server

    Howell, L W

    2002-01-01

    A simple power law model with single spectral index alpha sub 1 is believed to be an adequate description of the galactic cosmic-ray (GCR) proton flux at energies below 10 sup 1 sup 3 eV. Two procedures for estimating alpha sub 1 --the method of moments and maximum likelihood (ML)--are developed and their statistical performance are compared. The ML procedure is shown to be the superior approach and is then generalized for application to real cosmic-ray data sets. Several other important results, such as the relationship between collecting power and detector energy resolution and inclusion of a non-Gaussian detector response function, are presented. These results have many practical benefits in the design phase of a cosmic-ray detector as they permit instrument developers to make important trade studies in design parameters as a function of one of the science objectives.

  19. Small-scale engagement model with arrivals: analytical solutions

    International Nuclear Information System (INIS)

    Engi, D.

    1977-04-01

    This report presents an analytical model of small-scale battles. The specific impetus for this effort was provided by a need to characterize hypothetical battles between guards at a nuclear facility and their potential adversaries. The solution procedure can be used to find measures of a number of critical parameters; for example, the win probabilities and the expected duration of the battle. Numerical solutions are obtainable if the total number of individual combatants on the opposing sides is less than 10. For smaller force size battles, with one or two combatants on each side, symbolic solutions can be found. The symbolic solutions express the output parameters abstractly in terms of symbolic representations of the input parameters while the numerical solutions are expressed as numerical values. The input parameters are derived from the probability distributions of the attrition and arrival processes. The solution procedure reduces to solving sets of linear equations that have been constructed from the input parameters. The approach presented in this report does not address the problems associated with measuring the inputs. Rather, this report attempts to establish a relatively simple structure within which small-scale battles can be studied

  20. THE NEW SOLUTION OF TIME FRACTIONAL WAVE EQUATION WITH CONFORMABLE FRACTIONAL DERIVATIVE DEFINITION

    OpenAIRE

    Çenesiz, Yücel; Kurt, Ali

    2015-01-01

    – In this paper, we used new fractional derivative definition, the conformable fractional derivative, for solving two and three dimensional time fractional wave equation. This definition is simple and very effective in the solution procedures of the fractional differential equations that have complicated solutions with classical fractional derivative definitions like Caputo, Riemann-Liouville and etc. The results show that conformable fractional derivative definition is usable and convenient ...

  1. Low Cost, Simple, Intrauterine Insemination Procedure with ...

    African Journals Online (AJOL)

    During the last 30 years however, intrauterine insemination has evolved with the introduction of ovulation stimulating protocols and sperm preparation methods taken from assisted reproduction techniques. Costs have risen, but the success rate has not risen to the same extent. We have therefore developed a quite simple ...

  2. A simple surface treatment and characterization of AA 6061 aluminum alloy surface for adhesive bonding applications

    International Nuclear Information System (INIS)

    Saleema, N.; Sarkar, D.K.; Paynter, R.W.; Gallant, D.; Eskandarian, M.

    2012-01-01

    Highlights: ► A very simple surface treatment method to achieve excellent and durable aluminum adhesive bonding. ► Our method involves simple immersion of aluminum in very dilute NaOH solution at room temperature with no involvement of strong acids or multiple procedures. ► Surface analysis via various surface characterization techniques showed morphological and chemical modifications favorable for obtaining highly durable bond strengths on the treated surface. ► Safe, economical, reproducible and simple method, easily applicable in industries. - Abstract: Structural adhesive bonding of aluminum is widely used in aircraft and automotive industries. It has been widely noted that surface preparation of aluminum surfaces prior to adhesive bonding plays a significant role in improving the strength of the adhesive bond. Surface cleanliness, surface roughness, surface wettability and surface chemistry are controlled primarily by proper surface treatment methods. In this study, we have employed a very simple technique influencing all these criteria by simply immersing aluminum substrates in a very dilute solution of sodium hydroxide (NaOH) and we have studied the effect of varying the treatment period on the adhesive bonding characteristics. A bi-component epoxy adhesive was used to join the treated surfaces and the bond strengths were evaluated via single lap shear (SLS) tests in pristine as well as degraded conditions. Surface morphology, chemistry, crystalline nature and wettability of the NaOH treated surfaces were characterized using various surface analytical tools such as scanning electron microscopy and energy dispersive X-ray analysis (SEM/EDX), optical profilometry, infrared reflection absorption spectroscopy, X-ray photoelectron spectroscopy, X-ray diffraction and contact angle goniometry. Excellent adhesion characteristics with complete cohesive failure of the adhesive were encountered on the NaOH treated surfaces that are comparable to the benchmark

  3. Percutaneous Treatment of Simple Hepatic Cysts: The Long-Term Results of PAIR and Catheterization Techniques as Single-Session Procedures

    International Nuclear Information System (INIS)

    Akhan, Okan; Islim, Filiz; Balci, Sinan; Erbahceci, Aysun; Akpınar, Burcu; Ciftci, Turkmen; Akinci, Devrim

    2016-01-01

    PurposeThe purpose of our study is to evaluate results of percutaneous aspiration with alcohol sclerotherapy in symptomatic patients with simple hepatic cysts by employing single-session techniques either by a needle or a catheter.Materials and MethodsWe retrospectively included 39 simple hepatic cysts in 35 patients treated via percutaneous aspiration and single-session alcohol sclerotherapy between years 1993 and 2012. Indications were pain (n = 28) or ruling out cystic echinococcus (CE) disease (n = 7). 29 cysts in 26 patients were treated by needle technique (Group A) and ten cysts in nine patients were treated by single-session catheter technique (Group B). Patients were followed for 4–173 months (median: 38 months).ResultsAll patients were successfully treated. Before procedure, cyst volumes were 21–676 cc (median: 94 cc). Post-procedure cyst volumes at last follow-up were 0-40 cc (median: 1 cc). The mean decrease in cyst volume was 95.92 ± 2.86 % in all patients (95.96 ± 3.26 % in Group A and 95.80 ± 6.20 % in Group B). There was no statistically significant difference between the volume reduction rates of Group A and Group B. Only one patient, in Group B, developed a major complication, an abscess. Hospitalization period was 1 day for all patients.ConclusionsFor patients with symptomatic simple hepatic cysts smaller than 500 cc in volume by using puncture, aspiration, injection, and reaspiration (PAIR) technique with only needle, single-session alcohol sclerotherapy of 10 min is a safe and effective procedure with high success rate.

  4. Percutaneous Treatment of Simple Hepatic Cysts: The Long-Term Results of PAIR and Catheterization Techniques as Single-Session Procedures

    Energy Technology Data Exchange (ETDEWEB)

    Akhan, Okan, E-mail: akhano@tr.net [Hacettepe University Faculty of Medicine, Department of Radiology (Turkey); Islim, Filiz, E-mail: fislim@yahoo.com [Istanbul Bakirkoy Dr. Sadi Konuk Training and Research Hospital, Department of Radiology (Turkey); Balci, Sinan, E-mail: snnbalci@gmail.com [Hacettepe University Faculty of Medicine, Department of Radiology (Turkey); Erbahceci, Aysun, E-mail: aysunerbahceci@yahoo.com [Istanbul Bakirkoy Dr. Sadi Konuk Training and Research Hospital, Department of Radiology (Turkey); Akpınar, Burcu, E-mail: burcu-akpinar@yahoo.com; Ciftci, Turkmen, E-mail: turkmenciftci@yahoo.com; Akinci, Devrim, E-mail: akincid@hotmail.com [Hacettepe University Faculty of Medicine, Department of Radiology (Turkey)

    2016-06-15

    PurposeThe purpose of our study is to evaluate results of percutaneous aspiration with alcohol sclerotherapy in symptomatic patients with simple hepatic cysts by employing single-session techniques either by a needle or a catheter.Materials and MethodsWe retrospectively included 39 simple hepatic cysts in 35 patients treated via percutaneous aspiration and single-session alcohol sclerotherapy between years 1993 and 2012. Indications were pain (n = 28) or ruling out cystic echinococcus (CE) disease (n = 7). 29 cysts in 26 patients were treated by needle technique (Group A) and ten cysts in nine patients were treated by single-session catheter technique (Group B). Patients were followed for 4–173 months (median: 38 months).ResultsAll patients were successfully treated. Before procedure, cyst volumes were 21–676 cc (median: 94 cc). Post-procedure cyst volumes at last follow-up were 0-40 cc (median: 1 cc). The mean decrease in cyst volume was 95.92 ± 2.86 % in all patients (95.96 ± 3.26 % in Group A and 95.80 ± 6.20 % in Group B). There was no statistically significant difference between the volume reduction rates of Group A and Group B. Only one patient, in Group B, developed a major complication, an abscess. Hospitalization period was 1 day for all patients.ConclusionsFor patients with symptomatic simple hepatic cysts smaller than 500 cc in volume by using puncture, aspiration, injection, and reaspiration (PAIR) technique with only needle, single-session alcohol sclerotherapy of 10 min is a safe and effective procedure with high success rate.

  5. A PROCEDURAL SOLUTION TO MODEL ROMAN MASONRY STRUCTURES

    Directory of Open Access Journals (Sweden)

    V. Cappellini

    2013-07-01

    Full Text Available The paper will describe a new approach based on the development of a procedural modelling methodology for archaeological data representation. This is a custom-designed solution based on the recognition of the rules belonging to the construction methods used in roman times. We have conceived a tool for 3D reconstruction of masonry structures starting from photogrammetric surveying. Our protocol considers different steps. Firstly we have focused on the classification of opus based on the basic interconnections that can lead to a descriptive system used for their unequivocal identification and design. Secondly, we have chosen an automatic, accurate, flexible and open-source photogrammetric pipeline named Pastis Apero Micmac – PAM, developed by IGN (Paris. We have employed it to generate ortho-images from non-oriented images, using a user-friendly interface implemented by CNRS Marseille (France. Thirdly, the masonry elements are created in parametric and interactive way, and finally they are adapted to the photogrammetric data. The presented application, currently under construction, is developed with an open source programming language called Processing, useful for visual, animated or static, 2D or 3D, interactive creations. Using this computer language, a Java environment has been developed. Therefore, even if the procedural modelling reveals an accuracy level inferior to the one obtained by manual modelling (brick by brick, this method can be useful when taking into account the static evaluation on buildings (requiring quantitative aspects and metric measures for restoration purposes.

  6. a Procedural Solution to Model Roman Masonry Structures

    Science.gov (United States)

    Cappellini, V.; Saleri, R.; Stefani, C.; Nony, N.; De Luca, L.

    2013-07-01

    The paper will describe a new approach based on the development of a procedural modelling methodology for archaeological data representation. This is a custom-designed solution based on the recognition of the rules belonging to the construction methods used in roman times. We have conceived a tool for 3D reconstruction of masonry structures starting from photogrammetric surveying. Our protocol considers different steps. Firstly we have focused on the classification of opus based on the basic interconnections that can lead to a descriptive system used for their unequivocal identification and design. Secondly, we have chosen an automatic, accurate, flexible and open-source photogrammetric pipeline named Pastis Apero Micmac - PAM, developed by IGN (Paris). We have employed it to generate ortho-images from non-oriented images, using a user-friendly interface implemented by CNRS Marseille (France). Thirdly, the masonry elements are created in parametric and interactive way, and finally they are adapted to the photogrammetric data. The presented application, currently under construction, is developed with an open source programming language called Processing, useful for visual, animated or static, 2D or 3D, interactive creations. Using this computer language, a Java environment has been developed. Therefore, even if the procedural modelling reveals an accuracy level inferior to the one obtained by manual modelling (brick by brick), this method can be useful when taking into account the static evaluation on buildings (requiring quantitative aspects) and metric measures for restoration purposes.

  7. Solution-mediated cladding doping of commercial polymer optical fibers

    Science.gov (United States)

    Stajanca, Pavol; Topolniak, Ievgeniia; Pötschke, Samuel; Krebber, Katerina

    2018-03-01

    Solution doping of commercial polymethyl methacrylate (PMMA) polymer optical fibers (POFs) is presented as a novel approach for preparation of custom cladding-doped POFs (CD-POFs). The presented method is based on a solution-mediated diffusion of dopant molecules into the fiber cladding upon soaking of POFs in a methanol-dopant solution. The method was tested on three different commercial POFs using Rhodamine B as a fluorescent dopant. The dynamics of the diffusion process was studied in order to optimize the doping procedure in terms of selection of the most suitable POF, doping time and conditions. Using the optimized procedure, longer segment of fluorescent CD-POF was prepared and its performance was characterized. Fiber's potential for sensing and illumination applications was demonstrated and discussed. The proposed method represents a simple and cheap way for fabrication of custom, short to medium length CD-POFs with various dopants.

  8. The analysis of anode sludges, and their process solutions and beneficiation products

    International Nuclear Information System (INIS)

    Dixon, K.; Russell, G.M.; Wall, G.J.; Eddy, B.T.; Mallett, R.C.; Royal, S.J.

    1979-01-01

    As previous methods for the analysis of anode slimes have required lengthy separations, instrumental procedures were developed that require no preparation of the sample or only simple procedures such as acid digestion and fusion. Comparative values for various techniques are given. Methods for the analysis of process solutions and beneficiation products are examined and the procedures that have been adopted together with their relative merits and applicability are discussed. Methods of analysis include: atomic-absorption spectrophotometry, x-ray-fluorescence spectrophotometry, x-ray-fluorescence spectrometry, instrumental neutron-activation analysis and optical emission spectrometry

  9. A fast network solution by the decoupled procedure during short-term dynamic processes in power systems

    Energy Technology Data Exchange (ETDEWEB)

    Popovic, D P; Stefanovic, M D [Nikola Tesla Inst., Belgrade (YU). Power System Dept.

    1990-01-01

    A simple, fast and reliable decoupled procedure for solving the network problems during short-term dynamic processes in power systems is presented. It is based on the Newton-Raphson method applied to the power balance equations, which include the effects of generator saliency and non-impedance loads, with further modifications resulting from the physical properties of the phenomena under study. The good convergence characteristics of the developed procedure are demonstrated, and a comparison is made with the traditional method based on the current equation and the triangularized admittance matrix, using the example of stability analysis of the Yugoslav power grid. (author).

  10. Accuracy analysis of automodel solutions for Lévy flight-based transport: from resonance radiative transfer to a simple general model

    Science.gov (United States)

    Kukushkin, A. B.; Sdvizhenskii, P. A.

    2017-12-01

    The results of accuracy analysis of automodel solutions for Lévy flight-based transport on a uniform background are presented. These approximate solutions have been obtained for Green’s function of the following equations: the non-stationary Biberman-Holstein equation for three-dimensional (3D) radiative transfer in plasma and gases, for various (Doppler, Lorentz, Voigt and Holtsmark) spectral line shapes, and the 1D transport equation with a simple longtailed step-length probability distribution function with various power-law exponents. The results suggest the possibility of substantial extension of the developed method of automodel solution to other fields far beyond physics.

  11. Updating QR factorization procedure for solution of linear least squares problem with equality constraints.

    Science.gov (United States)

    Zeb, Salman; Yousaf, Muhammad

    2017-01-01

    In this article, we present a QR updating procedure as a solution approach for linear least squares problem with equality constraints. We reduce the constrained problem to unconstrained linear least squares and partition it into a small subproblem. The QR factorization of the subproblem is calculated and then we apply updating techniques to its upper triangular factor R to obtain its solution. We carry out the error analysis of the proposed algorithm to show that it is backward stable. We also illustrate the implementation and accuracy of the proposed algorithm by providing some numerical experiments with particular emphasis on dense problems.

  12. The soliton solution of the PHI24 field theory in the Hartree approximation

    International Nuclear Information System (INIS)

    Altenbokum, M.

    1984-01-01

    In this thesis in a simple model which possesses at the classical level a soliton solution a quantum-mechanical soliton sector shall be constructed in a Hartree-Fock approximation without application of semiclassical procedures. To this belongs beside the determination of the excitation spectrum of the applied Hamiltonian the knowledge of the corresponding infinitely-much eigenfunctions. The existing translational invariance of a classical soliton solution which implies the existence of a degenerated ground state by presence of a massless excitation is removed by quantum fluctuations. By removing of this degeneration conventional approximation procedures for this sector of the Hilbert space become for the first time immediately possible. (HSI) [de

  13. The Feasibility of Real-Time Intraoperative Performance Assessment With SIMPL (System for Improving and Measuring Procedural Learning): Early Experience From a Multi-institutional Trial.

    Science.gov (United States)

    Bohnen, Jordan D; George, Brian C; Williams, Reed G; Schuller, Mary C; DaRosa, Debra A; Torbeck, Laura; Mullen, John T; Meyerson, Shari L; Auyang, Edward D; Chipman, Jeffrey G; Choi, Jennifer N; Choti, Michael A; Endean, Eric D; Foley, Eugene F; Mandell, Samuel P; Meier, Andreas H; Smink, Douglas S; Terhune, Kyla P; Wise, Paul E; Soper, Nathaniel J; Zwischenberger, Joseph B; Lillemoe, Keith D; Dunnington, Gary L; Fryer, Jonathan P

    Intraoperative performance assessment of residents is of growing interest to trainees, faculty, and accreditors. Current approaches to collect such assessments are limited by low participation rates and long delays between procedure and evaluation. We deployed an innovative, smartphone-based tool, SIMPL (System for Improving and Measuring Procedural Learning), to make real-time intraoperative performance assessment feasible for every case in which surgical trainees participate, and hypothesized that SIMPL could be feasibly integrated into surgical training programs. Between September 1, 2015 and February 29, 2016, 15 U.S. general surgery residency programs were enrolled in an institutional review board-approved trial. SIMPL was made available after 70% of faculty and residents completed a 1-hour training session. Descriptive and univariate statistics analyzed multiple dimensions of feasibility, including training rates, volume of assessments, response rates/times, and dictation rates. The 20 most active residents and attendings were evaluated in greater detail. A total of 90% of eligible users (1267/1412) completed training. Further, 13/15 programs began using SIMPL. Totally, 6024 assessments were completed by 254 categorical general surgery residents (n = 3555 assessments) and 259 attendings (n = 2469 assessments), and 3762 unique operations were assessed. There was significant heterogeneity in participation within and between programs. Mean percentage (range) of users who completed ≥1, 5, and 20 assessments were 62% (21%-96%), 34% (5%-75%), and 10% (0%-32%) across all programs, and 96%, 75%, and 32% in the most active program. Overall, response rate was 70%, dictation rate was 24%, and mean response time was 12 hours. Assessments increased from 357 (September 2015) to 1146 (February 2016). The 20 most active residents each received mean 46 assessments by 10 attendings for 20 different procedures. SIMPL can be feasibly integrated into surgical training programs

  14. Phase equilibria of hydrogen sulfide and carbon dioxide simple hydrates in the presence of methanol, (methanol + NaCl) and (ethylene glycol + NaCl) aqueous solutions

    International Nuclear Information System (INIS)

    Mohammadi, Amir H.; Richon, Dominique

    2012-01-01

    Highlights: → Dissociation conditions of H 2 S or CO 2 hydrate + inhibitor aqueous solution are reported. → Methanol, methanol + NaCl and EG + NaCl aqueous solutions are considered as inhibitors. → Comparisons are made between our experimental data and the corresponding literature data. - Abstract: This work aims at reporting the dissociation pressures of hydrogen sulfide and carbon dioxide simple hydrates in the presence of methanol, (methanol + NaCl) and (ethylene glycol + NaCl) aqueous solutions at different temperatures and various concentrations of inhibitor in aqueous solution. The equilibrium results were generated using an isochoric pressure-search method. These values are compared with some selected experimental data from the literature on the dissociation conditions of hydrogen sulfide and carbon dioxide simple hydrates in the presence of pure water to show the inhibition effects of the above mentioned aqueous solutions. Comparisons are finally made between our experimental values and the corresponding literature data. Some disagreements among the literature data and our data are found.

  15. Riccati-parameter solutions of nonlinear second-order ODEs

    International Nuclear Information System (INIS)

    Reyes, M A; Rosu, H C

    2008-01-01

    It has been proven by Rosu and Cornejo-Perez (Rosu and Cornejo-Perez 2005 Phys. Rev. E 71 046607, Cornejo-Perez and Rosu 2005 Prog. Theor. Phys. 114 533) that for some nonlinear second-order ODEs it is a very simple task to find one particular solution once the nonlinear equation is factorized with the use of two first-order differential operators. Here, it is shown that an interesting class of parametric solutions is easy to obtain if the proposed factorization has a particular form, which happily turns out to be the case in many problems of physical interest. The method that we exemplify with a few explicitly solved cases consists in using the general solution of the Riccati equation, which contributes with one parameter to this class of parametric solutions. For these nonlinear cases, the Riccati parameter serves as a 'growth' parameter from the trivial null solution up to the particular solution found through the factorization procedure

  16. Computing multiple periodic solutions of nonlinear vibration problems using the harmonic balance method and Groebner bases

    Science.gov (United States)

    Grolet, Aurelien; Thouverez, Fabrice

    2015-02-01

    This paper is devoted to the study of vibration of mechanical systems with geometric nonlinearities. The harmonic balance method is used to derive systems of polynomial equations whose solutions give the frequency component of the possible steady states. Groebner basis methods are used for computing all solutions of polynomial systems. This approach allows to reduce the complete system to an unique polynomial equation in one variable driving all solutions of the problem. In addition, in order to decrease the number of variables, we propose to first work on the undamped system, and recover solution of the damped system using a continuation on the damping parameter. The search for multiple solutions is illustrated on a simple system, where the influence of the retained number of harmonic is studied. Finally, the procedure is applied on a simple cyclic system and we give a representation of the multiple states versus frequency.

  17. [Effects of different types and concentration of oral sweet solution on reducing neonatal pain during heel lance procedures].

    Science.gov (United States)

    Leng, Hong-yao; Zheng, Xian-lan; Yan, Li; Zhang, Xian-hong; He, Hua-yun; Xiang, Ming

    2013-09-01

    To compare the effect of different types and concentrations of sweet solutions on neonatal pain during heel lance procedure. Totally 560 full term neonates (male 295, female 265) were randomized into 7 groups:placebo group (plain water), 10% glucose, 25% glucose, 50% glucose, 12% sucrose, 24% sucrose and 30% sucrose groups.In each group, 2 ml corresponding oral solutions were administered through a syringe by dripping into the neonate's mouth 2 minute before heel lance. The procedure process was recorded by videos, from which to collect heart rate, oxygen saturation and pain score 1 min before puncture, 3, 5 and 10 min after puncture. The average heart rate increase 3, 5 and 10 min after procedure in the 25% and 50% glucose groups, 12% and 24% and 30% sucrose groups was significantly lower than those in the placebo group (P lance (both P lance, but the best concentration of sucrose for pain relief needs further study.

  18. Simple and Accurate Analytical Solutions of the Electrostatically Actuated Curled Beam Problem

    KAUST Repository

    Younis, Mohammad I.

    2014-08-17

    We present analytical solutions of the electrostatically actuated initially deformed cantilever beam problem. We use a continuous Euler-Bernoulli beam model combined with a single-mode Galerkin approximation. We derive simple analytical expressions for two commonly observed deformed beams configurations: the curled and tilted configurations. The derived analytical formulas are validated by comparing their results to experimental data in the literature and numerical results of a multi-mode reduced order model. The derived expressions do not involve any complicated integrals or complex terms and can be conveniently used by designers for quick, yet accurate, estimations. The formulas are found to yield accurate results for most commonly encountered microbeams of initial tip deflections of few microns. For largely deformed beams, we found that these formulas yield less accurate results due to the limitations of the single-mode approximations they are based on. In such cases, multi-mode reduced order models need to be utilized.

  19. Simple estimation procedures for regression analysis of interval-censored failure time data under the proportional hazards model.

    Science.gov (United States)

    Sun, Jianguo; Feng, Yanqin; Zhao, Hui

    2015-01-01

    Interval-censored failure time data occur in many fields including epidemiological and medical studies as well as financial and sociological studies, and many authors have investigated their analysis (Sun, The statistical analysis of interval-censored failure time data, 2006; Zhang, Stat Modeling 9:321-343, 2009). In particular, a number of procedures have been developed for regression analysis of interval-censored data arising from the proportional hazards model (Finkelstein, Biometrics 42:845-854, 1986; Huang, Ann Stat 24:540-568, 1996; Pan, Biometrics 56:199-203, 2000). For most of these procedures, however, one drawback is that they involve estimation of both regression parameters and baseline cumulative hazard function. In this paper, we propose two simple estimation approaches that do not need estimation of the baseline cumulative hazard function. The asymptotic properties of the resulting estimates are given, and an extensive simulation study is conducted and indicates that they work well for practical situations.

  20. Simple de Sitter solutions

    International Nuclear Information System (INIS)

    Silverstein, Eva

    2008-01-01

    We present a framework for de Sitter model building in type IIA string theory, illustrated with specific examples. We find metastable de Sitter (dS) minima of the potential for moduli obtained from a compactification on a product of two nil three-manifolds (which have negative scalar curvature) combined with orientifolds, branes, fractional Chern-Simons forms, and fluxes. As a discrete quantum number is taken large, the curvature, field strengths, inverse volume, and four-dimensional string coupling become parametrically small, and the de Sitter Hubble scale can be tuned parametrically smaller than the scales of the moduli, Kaluza Klein (KK), and winding mode masses. A subtle point in the construction is that although the curvature remains consistently weak, the circle fibers of the nilmanifolds become very small in this limit (though this is avoided in illustrative solutions at modest values of the parameters). In the simplest version of the construction, the heaviest moduli masses are parametrically of the same order as the lightest KK and winding masses. However, we provide a method for separating these marginally overlapping scales, and more generally the underlying supersymmetry of the model protects against large corrections to the low-energy moduli potential

  1. Exact solutions for chemical bond orientations from residual dipolar couplings

    International Nuclear Information System (INIS)

    Wedemeyer, William J.; Rohl, Carol A.; Scheraga, Harold A.

    2002-01-01

    New methods for determining chemical structures from residual dipolar couplings are presented. The fundamental dipolar coupling equation is converted to an elliptical equation in the principal alignment frame. This elliptical equation is then combined with other angular or dipolar coupling constraints to form simple polynomial equations that define discrete solutions for the unit vector(s). The methods are illustrated with residual dipolar coupling data on ubiquitin taken in a single anisotropic medium. The protein backbone is divided into its rigid groups (namely, its peptide planes and C α frames), which may be solved for independently. A simple procedure for recombining these independent solutions results in backbone dihedral angles φ and ψ that resemble those of the known native structure. Subsequent refinement of these φ-ψ angles by the ROSETTA program produces a structure of ubiquitin that agrees with the known native structure to 1.1 A C α rmsd

  2. Solution of the schrodinger equation in one dimension by simple method for a simple step potential

    International Nuclear Information System (INIS)

    Ertik, H.

    2005-01-01

    The coefficients of the transmission and reflection for the simple-step barrier potential were calculated by a simple method. Their values were entirely different from those often encountered in the literature. Especially in the case that the total energy is equal to the barrier potential, the value of 0,20 for the reflection coefficient was obtained whereas this is zero in the literature. This may be considered as an interesting point

  3. Exact solution for stresses/displacements in a multilayered hollow cylinder under thermo-mechanical loading

    International Nuclear Information System (INIS)

    Yeo, W.H.; Purbolaksono, J.; Aliabadi, M.H.; Ramesh, S.; Liew, H.L.

    2017-01-01

    In this study, a new analytical solution by the recursive method for evaluating stresses/displacements in multilayered hollow cylinder under thermo-mechanical loading was developed. The results for temperature distribution, displacements and stresses obtained by using the proposed solution were shown to be in good agreement with the FEM results. The proposed analytical solution was also found to produce more accurate results than those by the analytical solution reported in literature. - Highlights: • A new analytical solution for evaluating stresses in multilayered hollow cylinder under thermo-mechanical loading. • A simple computational procedure using a recursive method. • A promising technique for evaluating the operating axial and hoop stresses in pressurized composite vessels.

  4. Analytical solution to the 1D Lemaitre's isotropic damage model and plane stress projected implicit integration procedure

    DEFF Research Database (Denmark)

    Andriollo, Tito; Thorborg, Jesper; Hattel, Jesper Henri

    2016-01-01

    obtaining an integral relationship between total strain and effective stress. By means of the generalized binomial theorem, an expression in terms of infinite series is subsequently derived. The solution is found to simplify considerably existing techniques for material parameters identification based...... on optimization, as all issues associated with classical numerical solution procedures of the constitutive equations are eliminated. In addition, an implicit implementation of the plane stress projected version of Lemaitre's model is discussed, showing that the resulting algebraic system can be reduced...

  5. Solution procedure and performance evaluation for a water–LiBr absorption refrigeration machine

    International Nuclear Information System (INIS)

    Wonchala, Jason; Hazledine, Maxwell; Goni Boulama, Kiari

    2014-01-01

    The water–lithium bromide absorption cooling machine was investigated theoretically in this paper. A detailed solution procedure was proposed and validated. A parametric study was conducted over the entire admissible ranges of the desorber, condenser, absorber and evaporator temperatures. The performance of the machine was evaluated based on the circulation ratio which is a measure of the system size and cost, the first law coefficient of performance and the second law exergy efficiency. The circulation ratio and the coefficient of performance were seen to improve as the temperature of the heat source increased, while the second law performance deteriorated. The same qualitative responses were obtained when the temperature of the refrigerated environment was increased. On the other hand, simultaneously raising the condenser and absorber temperatures was seen to result in a severe deterioration of both the circulation ratio and first law coefficient of performance, while the second law performance indicator improved significantly. The influence of the difference between the condenser and absorber exit temperatures, as well as that of the internal recovery heat exchanger on the different performance indicators was also calculated and discussed. - Highlights: • Analysis of a water–LiBr absorption machine, including detailed solution procedure. • Performance assessed using first and second law considerations, as well as flow ratio. • Effects of heat source and refrigerated environment temperatures on the performance. • Effects of the difference between condenser and absorber temperatures. • Effects of internal heat exchanger efficiency on overall cooling machine performance

  6. A molecular-thermodynamic model for polyelectrolyte solutions

    Energy Technology Data Exchange (ETDEWEB)

    Jiang, J.; Liu, H.; Hu, Y. [Thermodynamics Research Laboratory, East China University of Science and Technology, Shanghai 200237 (China); Prausnitz, J.M. [Department of Chemical Engineering, University of California, Berkeley, and Chemical Sciences Division, Lawrence Berkeley Laboratory, University of California, Berkeley, California 94720 (United States)

    1998-01-01

    Polyelectrolyte solutions are modeled as freely tangent-jointed, charged hard-sphere chains and corresponding counterions in a continuum medium with permitivity {var_epsilon}. By adopting the sticky-point model, the Helmholtz function for polyelectrolyte solutions is derived through the r-particle cavity-correlation function (CCF) for chains of sticky, charged hard spheres. The r-CCF is approximated by a product of effective nearest-neighbor two-particle CCFs; these are determined from the hypernetted-chain and mean-spherical closures (HNC/MSA) inside and outside the hard core, respectively, for the integral equation theory for electrolytes. The colligative properties are given as explicit functions of a scaling parameter {Gamma} that can be estimated by a simple iteration procedure. Osmotic pressures, osmotic coefficients, and activity coefficients are calculated for model solutions with various chain lengths. They are in good agreement with molecular simulation and experimental results. {copyright} {ital 1998 American Institute of Physics.}

  7. Simple multicomponent batch distillation procedure with a variable reflux policy

    Directory of Open Access Journals (Sweden)

    A. N. García

    2014-06-01

    Full Text Available This paper describes a shortcut procedure for batch distillation simulation with a variable reflux policy. The procedure starts from a shortcut method developed by Sundaram and Evans in 1993 and uses an iterative cycle to calculate the reflux ratio at each moment. The functional relationship between the concentrations at the bottom and the dome is evaluated using the Fenske equation and is complemented with the equations proposed by Underwood and Gilliland. The results of this procedure are consistent with those obtained using a fast method widely validated in the relevant literature.

  8. A simple, analytical model of collisionless magnetic reconnection in a pair plasma

    International Nuclear Information System (INIS)

    Hesse, Michael; Zenitani, Seiji; Kuznetsova, Masha; Klimas, Alex

    2009-01-01

    A set of conservation equations is utilized to derive balance equations in the reconnection diffusion region of a symmetric pair plasma. The reconnection electric field is assumed to have the function to maintain the current density in the diffusion region and to impart thermal energy to the plasma by means of quasiviscous dissipation. Using these assumptions it is possible to derive a simple set of equations for diffusion region parameters in dependence on inflow conditions and on plasma compressibility. These equations are solved by means of a simple, iterative procedure. The solutions show expected features such as dominance of enthalpy flux in the reconnection outflow, as well as combination of adiabatic and quasiviscous heating. Furthermore, the model predicts a maximum reconnection electric field of E * =0.4, normalized to the parameters at the inflow edge of the diffusion region.

  9. A Simple, Analytical Model of Collisionless Magnetic Reconnection in a Pair Plasma

    Science.gov (United States)

    Hesse, Michael; Zenitani, Seiji; Kuznetova, Masha; Klimas, Alex

    2011-01-01

    A set of conservation equations is utilized to derive balance equations in the reconnection diffusion region of a symmetric pair plasma. The reconnection electric field is assumed to have the function to maintain the current density in the diffusion region, and to impart thermal energy to the plasma by means of quasi-viscous dissipation. Using these assumptions it is possible to derive a simple set of equations for diffusion region parameters in dependence on inflow conditions and on plasma compressibility. These equations are solved by means of a simple, iterative, procedure. The solutions show expected features such as dominance of enthalpy flux in the reconnection outflow, as well as combination of adiabatic and quasi-viscous heating. Furthermore, the model predicts a maximum reconnection electric field of E(sup *)=0.4, normalized to the parameters at the inflow edge of the diffusion region.

  10. A procedure for solving the neutron diffusion equation on a parallel micro-processor; modifications to the nodal expansion codes RECNEC and HEXNEC to implement the procedure

    International Nuclear Information System (INIS)

    Putney, J.M.

    1983-05-01

    The characteristics of a simple parallel micro-processor (PMP) are reviewed and its software requirements discussed. One of the more immediate applications is the multi-spatial simulation of a nuclear reactor station. This is of particular interest because 3D reactor simulation might then be possible as part of operating procedure for PFR and CDFR. A major part of a multi-spatial reactor simulator is the solution of the neutron diffusion equation. A procedure is described for solving the equation on a PMP, which is applied to the nodal expansion method with modifications to the nodal expansion codes RECNEC and HEXNEC. Estimations of the micro-processor requirements for the simulation of both PFR and CDFR are given. (U.K.)

  11. Comparison of simple and economical photocatalyst immobilisation procedures

    DEFF Research Database (Denmark)

    Lim, L.L.P.; Lynch, R.J.; In, Su-il

    2009-01-01

    Photocatalysis is extremely useful for the removal of organic contaminants in water. However, the conditions used for preparing and fixing the catalyst to a substrate have a great effect on its performance. The determination of a suitable immobilisation procedure for specific application becomes...

  12. Solution Procedure for Transport Modeling in Effluent Recharge Based on Operator-Splitting Techniques

    Directory of Open Access Journals (Sweden)

    Shutang Zhu

    2008-01-01

    Full Text Available The coupling of groundwater movement and reactive transport during groundwater recharge with wastewater leads to a complicated mathematical model, involving terms to describe convection-dispersion, adsorption/desorption and/or biodegradation, and so forth. It has been found very difficult to solve such a coupled model either analytically or numerically. The present study adopts operator-splitting techniques to decompose the coupled model into two submodels with different intrinsic characteristics. By applying an upwind finite difference scheme to the finite volume integral of the convection flux term, an implicit solution procedure is derived to solve the convection-dominant equation. The dispersion term is discretized in a standard central-difference scheme while the dispersion-dominant equation is solved using either the preconditioned Jacobi conjugate gradient (PJCG method or Thomas method based on local-one-dimensional scheme. The solution method proposed in this study is applied to the demonstration project of groundwater recharge with secondary effluent at Gaobeidian sewage treatment plant (STP successfully.

  13. Computer assisted procedure maintenance

    International Nuclear Information System (INIS)

    Bisio, R.; Hulsund, J. E.; Nilsen, S.

    2004-04-01

    The maintenance of operating procedures in a NPP is a tedious and complicated task. Through the whole life cycle of the procedures they will be dynamic, 'living' documents. Several aspects of the procedure must be considered in a revision process. Pertinent details and attributes of the procedure must be checked. An organizational structure must be created and responsibilities allotted for drafting, revising, reviewing and publishing procedures. Available powerful computer technology provides solutions within document management and computerisation of procedures. These solutions can also support the maintenance of procedures. Not all parts of the procedure life cycle are equally amenable to computerized support. This report looks at the procedure life cycle in todays NPPs and discusses the possibilities associated with introduction of computer technology to assist the maintenance of procedures. (Author)

  14. LASL lens design procedure: simple, fast, precise, versatile

    International Nuclear Information System (INIS)

    Brixner, B.

    1978-11-01

    The Los Alamos Scientific Laboratory general-purpose lens design procedure optimizes specific lens prescriptions to obtain the smallest possible image spots and therefore near-spherical wave fronts of light converging on all images in the field of view. Optical image errors are analyzed in much the same way that they are measured on the optical bench. This lens design method is made possible by using the full capabilities of large electronic computers. First, the performance of the whole lens is sampled with many precisely traced skew rays. Next, lens performance is analyzed with spot diagrams generated by the many rays. Third, lens performance is optimized with a least squares system aimed at reducing all image errors to zero. This statistical approach to lens design uses skew rays and precisely measured ray deviations from ideal image points to achieve greater accuracy than was possible with the classical procedure, which is based on approximate expressions derived from simplified ray traces developed for pencil-and-paper calculations

  15. Catalyzed reduction of nitrate in aqueous solutions

    International Nuclear Information System (INIS)

    Haas, P.A.

    1994-08-01

    Sodium nitrate and other nitrate salts in wastes is a major source of difficulty for permanent disposal. Reduction of nitrate using aluminum metal has been demonstrated, but NH 3 , hydrazine, or organic compounds containing oxygen would be advantageous for reduction of nitrate in sodium nitrate solutions. Objective of this seed money study was to determine minimum conditions for reduction. Proposed procedure was batchwise heating of aqueous solutions in closed vessels with monitoring of temperatures and pressures. A simple, convenient apparatus and procedure were demonstrated for observing formation of gaseous products and collecting samples for analyses. The test conditions were 250 degree C and 1000 psi max. Any useful reduction of sodium nitrate to sodium hydroxide as the primary product was not found. The nitrate present at pHs 3 or NH 4 NO 3 is easily decomposed, and the effect of nitromethane at these low pHs was confirmed. When acetic acid or formic acid was added, 21 to 56% of the nitrate in sodium nitrate solutions was reduced by methanol or formaldehyde. With hydrazine and acetic acid, 73 % of the nitrate was decomposed to convert NaNO 3 to sodium acetate. With hydrazine and formic acid, 36% of the nitrate was decomposed. If these products are more acceptable for final disposal than sodium nitrate, the reagents are cheap and the conversion conditions would be practical for easy use. Ammonium acetate or formate salts did not significantly reduce nitrate in sodium nitrate solutions

  16. Simple models with ALICE fluxes

    CERN Document Server

    Striet, J

    2000-01-01

    We introduce two simple models which feature an Alice electrodynamics phase. In a well defined sense the Alice flux solutions we obtain in these models obey first order equations similar to those of the Nielsen-Olesen fluxtube in the abelian higgs model in the Bogomol'nyi limit. Some numerical solutions are presented as well.

  17. A Simple FDTD Algorithm for Simulating EM-Wave Propagation in General Dispersive Anisotropic Material

    KAUST Repository

    Al-Jabr, Ahmad Ali; Alsunaidi, Mohammad A.; Ng, Tien Khee; Ooi, Boon S.

    2013-01-01

    In this paper, an finite-difference time-domain (FDTD) algorithm for simulating propagation of EM waves in anisotropic material is presented. The algorithm is based on the auxiliary differential equation and the general polarization formulation. In anisotropic materials, electric fields are coupled and elements in the permittivity tensor are, in general, multiterm dispersive. The presented algorithm resolves the field coupling using a formulation based on electric polarizations. It also offers a simple procedure for the treatment of multiterm dispersion in the FDTD scheme. The algorithm is tested by simulating wave propagation in 1-D magnetized plasma showing excellent agreement with analytical solutions. Extension of the algorithm to multidimensional structures is straightforward. The presented algorithm is efficient and simple compared to other algorithms found in the literature. © 2012 IEEE.

  18. A Simple FDTD Algorithm for Simulating EM-Wave Propagation in General Dispersive Anisotropic Material

    KAUST Repository

    Al-Jabr, Ahmad Ali

    2013-03-01

    In this paper, an finite-difference time-domain (FDTD) algorithm for simulating propagation of EM waves in anisotropic material is presented. The algorithm is based on the auxiliary differential equation and the general polarization formulation. In anisotropic materials, electric fields are coupled and elements in the permittivity tensor are, in general, multiterm dispersive. The presented algorithm resolves the field coupling using a formulation based on electric polarizations. It also offers a simple procedure for the treatment of multiterm dispersion in the FDTD scheme. The algorithm is tested by simulating wave propagation in 1-D magnetized plasma showing excellent agreement with analytical solutions. Extension of the algorithm to multidimensional structures is straightforward. The presented algorithm is efficient and simple compared to other algorithms found in the literature. © 2012 IEEE.

  19. A simple modelling of mass diffusion effects on condensation with noncondensable gases for the CATHARE Code

    Energy Technology Data Exchange (ETDEWEB)

    Coste, P.; Bestion, D. [Commissariat a l Energie Atomique, Grenoble (France)

    1995-09-01

    This paper presents a simple modelling of mass diffusion effects on condensation. In presence of noncondensable gases, the mass diffusion near the interface is modelled using the heat and mass transfer analogy and requires normally an iterative procedure to calculate the interface temperature. Simplifications of the model and of the solution procedure are used without important degradation of the predictions. The model is assessed on experimental data for both film condensation in vertical tubes and direct contact condensation in horizontal tubes, including air-steam, Nitrogen-steam and Helium-steam data. It is implemented in the Cathare code, a french system code for nuclear reactor thermal hydraulics developed by CEA, EDF, and FRAMATOME.

  20. A simple model for predicting solute concentration in agricultural tile lines shortly after application

    Directory of Open Access Journals (Sweden)

    T. S. Steenhuis

    1997-01-01

    Full Text Available Agricultural tile drainage lines have been implicated as a source of pesticide contamination of surface waters. Field experiments were conducted and a simple model was developed to examine preferential transport of applied chemicals to agricultural tile lines. The conceptual model consists of two linear reservoirs, one near the soil surface and one near the tile drain. The connection between the two reservoirs is via preferential flow paths with very little interaction with the soil matrix. The model assumes that only part of the field contributes solutes to the tile drain. The model was evaluated with data from the field experiments in which chloride, 2,4-D, and atrazine concentrations were measured on eight tile-drained plots that were irrigated twice. Atrazine was applied two months prior to the experiment, 2,4-D was sprayed just before the first irrigation, and chloride before the second irrigation. All three chemicals were found in the tile effluent shortly after the rainfall began. Generally, the concentration increased with increased flow rates and decreased exponentially after the rainfall ceased. Although the simple model could simulate the observed chloride concentration patterns in the tile outflow for six of the eight plots, strict validation was not possible because of the difficulty with independent measurement of the data needed for a preferential flow model applied to field conditions. The results show that, to simulate pesticide concentration in tile lines, methods that can measure field averaged preferential flow characteristics need to be developed.

  1. A simple electron plasma wave

    International Nuclear Information System (INIS)

    Brodin, G.; Stenflo, L.

    2017-01-01

    Considering a class of solutions where the density perturbations are functions of time, but not of space, we derive a new exact large amplitude wave solution for a cold uniform electron plasma. This result illustrates that most simple analytical solutions can appear even if the density perturbations are large. - Highlights: • The influence of large amplitude electromagnetic waves on electrostatic oscillations is found. • A generalized Mathieu equation is derived. • Anharmonic wave profiles are computed numerically.

  2. A simple electron plasma wave

    Energy Technology Data Exchange (ETDEWEB)

    Brodin, G., E-mail: gert.brodin@physics.umu.se [Department of Physics, Umeå University, SE-901 87 Umeå (Sweden); Stenflo, L. [Department of Physics, Linköping University, SE-581 83 Linköping (Sweden)

    2017-03-18

    Considering a class of solutions where the density perturbations are functions of time, but not of space, we derive a new exact large amplitude wave solution for a cold uniform electron plasma. This result illustrates that most simple analytical solutions can appear even if the density perturbations are large. - Highlights: • The influence of large amplitude electromagnetic waves on electrostatic oscillations is found. • A generalized Mathieu equation is derived. • Anharmonic wave profiles are computed numerically.

  3. Procedural sedation analgesia

    OpenAIRE

    Sheta, Saad A

    2010-01-01

    The number of noninvasive and minimally invasive procedures performed outside of the operating room has grown exponentially over the last several decades. Sedation, analgesia, or both may be needed for many of these interventional or diagnostic procedures. Individualized care is important when determining if a patient requires procedural sedation analgesia (PSA). The patient might need an anti-anxiety drug, pain medicine, immobilization, simple reassurance, or a combination of these interve...

  4. An alternative procedure for estimating the population mean in simple random sampling

    Directory of Open Access Journals (Sweden)

    Housila P. Singh

    2012-03-01

    Full Text Available This paper deals with the problem of estimating the finite population mean using auxiliary information in simple random sampling. Firstly we have suggested a correction to the mean squared error of the estimator proposed by Gupta and Shabbir [On improvement in estimating the population mean in simple random sampling. Jour. Appl. Statist. 35(5 (2008, pp. 559-566]. Later we have proposed a ratio type estimator and its properties are studied in simple random sampling. Numerically we have shown that the proposed class of estimators is more efficient than different known estimators including Gupta and Shabbir (2008 estimator.

  5. A simple unifying procedure for radioimmunoassay of thyroxine, triiodothyronine and reverse triiodothyronine in unextracted serum

    International Nuclear Information System (INIS)

    Slebodzinski, A.B.; Nowak, G.; Zamyslowska, H.

    1980-01-01

    A simple unifying procedure for radioimmunoassay (RIA) of thyroxine, T 4 , triiodothyronine, T 3 , and reverse-triiodothyronine, rT 3 , in unextracted serum has been developed. In the method 8-anilino-naphthalene sulfonic acid, sodium salicylate and barbital were used as inhibitors of iodothyronine binding to proteins of serum and charcoal for separation of antibody-bound and free hormone fractions. For statistical evaluation and quality control of the results the assay data were analyzed after logit/log transformation. In this way, a reasonable linearization of the standard curve was achieved. The lower limit of detection of T 4 was 35 pg and for triiodothyronine (T 3 plus rT 3 ) 7.5 pg. The intraassay variability averaged from 5-7%. Corresponding betweenassay coefficient of variation was from 11-13%. The recovery of added hormone to the hormone-free serum was near 100%, and the index of precision (lambda) below 0.1. The useable range of hormone determination was found to be from 0.5 μg to 15 μg T 4 and from 15 to 200 ng T 3 or rT 3 per dl serum. Using this unifying procedure one person can perform about 120 determinations per day. After logit/log transformation of the input data and linearization of the standard curve, the statistical analysis and data processing can be easily performed by a suitable RIA programme for a top desk calculator. (author)

  6. Survey of a numerical procedure for the solution of hyperbolic systems of three dimensional fluid flow

    International Nuclear Information System (INIS)

    Graf, U.

    1986-01-01

    A combination of several numerical methods is used to construct a procedure for effective calculation of complex three-dimensional fluid flow problems. The split coefficient matrix (SCM) method is used so that the differenced equations of the hyperbolic system do not disturb correct signal propagation. The semi-discretisation of the equations of the SCM method is done with the asymmetric, separated region, weighted residual (ASWR) method to give accurate solutions on a relatively coarse mesh. For the resulting system of ordinary differential equations, a general-purpose ordinary differential equation solver is used in conjunction with a method of fractional steps for an economic solution of the large system of linear equations. (orig.) [de

  7. Inverse Scattering Method and Soliton Solution Family for String Effective Action

    International Nuclear Information System (INIS)

    Ya-Jun, Gao

    2009-01-01

    A modified Hauser–Ernst-type linear system is established and used to develop an inverse scattering method for solving the motion equations of the string effective action describing the coupled gravity, dilaton and Kalb–Ramond fields. The reduction procedures in this inverse scattering method are found to be fairly simple, which makes the proposed inverse scattering method applied fine and effective. As an application, a concrete family of soliton solutions for the considered theory is obtained

  8. A procedure for preferential trapping of cesium cations from aqueous solutions and their separation from other inorganic cations

    International Nuclear Information System (INIS)

    Plesek, J.; Hermanek, S.; Selucky, P.; Williams, R.E.

    1995-01-01

    The title procedure is as follows. Deltahedral heteroborane anions are added to the aqueous solution containing cesium ions, precipitate (if any) is separated off, and the cesium salts involving the deltahedral heteroborane anions are trapped on activated carbon. The cobaltocarborane anion [3-Co-(1,2-C 2 B 9 H 11 ) 2 ] and/or its substitution derivatives are particularly well suited to this purpose. The process can find use in the separation of radionuclides present in waste solutions arising from spent nuclear fuel treatment. (P.A.). 1 fig

  9. General exact solution for homogeneous time-dependent self-gravitating perfect fluids

    International Nuclear Information System (INIS)

    Gaete, P.; Hojman, R.

    1988-01-01

    A procedure to obtain the general exact solution of Einstein equations for a self-gravitating spherically-symmetric static perfect fluid obeying an arbitrary equation of state, is applied to time-dependent Kantowsky-Sachs line elements (with spherical, planar and hyperbolic symmetry). As in the static case, the solution is generated by an arbitrary function of the independent variable and its first derivative. To illustrate the results, the whole family of (plane-symmetric) solutions with a ''gamma-law'' equation of state is explicity obtained in terms of simple known functions. It is also shown that, while in the static plane-symmtric line elements, every metric is in one to one correspondence with a ''partner-metric'' (both originated from the same generatrix function), in this case every generatrix function univocally determines one metric. (author) [pt

  10. Patterned forests of vertically-aligned multiwalled carbon nanotubes using metal salt catalyst solutions.

    Science.gov (United States)

    Garrett, David J; Flavel, Benjamin S; Baronian, Keith H R; Downard, Alison J

    2013-01-01

    A simple method for producing patterned forests of multiwalled carbon nanotubes (MWCNTs) is described. An aqueous metal salt solution is spin-coated onto a substrate patterned with photoresist by standard methods. The photoresist is removed by acetone washing leaving the acetone-insoluble catalyst pattern on the substrate. Dense forests of vertically aligned (VA) MWCNTs are grown on the patterned catalyst layers by chemical vapour deposition. The procedures have been demonstrated by growing MWCNT forests on two substrates: silicon and conducting graphitic carbon films. The forests adhere strongly to the substrates and when grown directly on carbon film, offer a simple method of preparing MWCNT electrodes.

  11. A simple and efficient procedure to enhance artemisinin content in ...

    African Journals Online (AJOL)

    SERVER

    2007-06-18

    Jun 18, 2007 ... Full Length Research Paper. A simple .... The leaf material after the extraction was weighed (to measure the dry ... standard control in the measurement. ..... Ro DK, Paradise EM, Ouellet M, Fisher KJ, Newman KL, Ndungu JM,.

  12. Parametric oscillators from factorizations employing a constant-shifted Riccati solution of the classical harmonic oscillator

    Energy Technology Data Exchange (ETDEWEB)

    Rosu, H.C., E-mail: hcr@ipicyt.edu.mx [IPICyT, Instituto Potosino de Investigacion Cientifica y Tecnologica, Apdo Postal 3-74 Tangamanga, 78231 San Luis Potosi, S.L.P. (Mexico); Khmelnytskaya, K.V. [Universidad Autonoma de Queretaro, Centro Universitario, Cerro de las Campanas s/n, C.P. 76010 Santiago de Queretaro, Qro. (Mexico)

    2011-09-19

    We determine the kind of parametric oscillators that are generated in the usual factorization procedure of second-order linear differential equations when one introduces a constant shift of the Riccati solution of the classical harmonic oscillator. The mathematical results show that some of these oscillators could be of physical nature. We give the solutions of the obtained second-order differential equations and the values of the shift parameter providing strictly periodic and antiperiodic solutions. We also notice that this simple problem presents parity-time (PT) symmetry. Possible applications are mentioned. -- Highlights: → A particular Riccati solution of the classical harmonic oscillator is shifted by a constant. → Such a solution is used in the factorization brackets to get different equations of motion. → The properties of the parametric oscillators obtained in this way are examined.

  13. A single-step simultaneous protein staining procedure for polyacrylamide gels and nitrocellulose membranes by Alta during western blot analysis.

    Science.gov (United States)

    Pal, Jayanta K; Berwal, Sunil K; Soni, Rupali N

    2012-01-01

    A simple method for staining of proteins simultaneously on sodium dodecyl sulfate (SDS) polyacrylamide gels and nitrocellulose membranes by Alta during western blot analysis is described. A 5% solution of Alta, a commercially available cosmetic preparation, is added in the upper tank buffer during electrophoresis. On completion of electrophoresis, the gel is washed in distilled water and viewed on a white light plate and a transilluminator to photograph the protein profiles. The gel is processed for western blot transfer of proteins onto a nitrocellulose membrane, and upon completion, the protein profiles on the membrane are viewed and photographed as stated above. The membrane can then be processed for immunostaining as per the standard procedure. Thus, the staining procedure using Alta is simple, rapid (without any need of destaining), and cost-effective.

  14. Parallel iterative procedures for approximate solutions of wave propagation by finite element and finite difference methods

    Energy Technology Data Exchange (ETDEWEB)

    Kim, S. [Purdue Univ., West Lafayette, IN (United States)

    1994-12-31

    Parallel iterative procedures based on domain decomposition techniques are defined and analyzed for the numerical solution of wave propagation by finite element and finite difference methods. For finite element methods, in a Lagrangian framework, an efficient way for choosing the algorithm parameter as well as the algorithm convergence are indicated. Some heuristic arguments for finding the algorithm parameter for finite difference schemes are addressed. Numerical results are presented to indicate the effectiveness of the methods.

  15. A simple solution to type specialization

    DEFF Research Database (Denmark)

    Danvy, Olivier

    1998-01-01

    Partial evaluation specializes terms, but traditionally this specialization does not apply to the type of these terms. As a result, specializing, e.g., an interpreter written in a typed language, which requires a “universal” type to encode expressible values, yields residual programs with type tags...... all over. Neil Jones has stated that getting rid of these type tags was an open problem, despite possible solutions such as Torben Mogensen's “constructor specialization.” To solve this problem, John Hughes has proposed a new paradigm for partial evaluation, “Type Specialization”, based on type...... from the universal type to the specific type of the residual program. Standard partial evaluation then yields a residual program without type tags, simply and efficiently....

  16. A SIMPLE AND EFFECTIVE CURSIVE WORD SEGMENTATION METHOD

    NARCIS (Netherlands)

    nicchiotti, G.; Rimassa, S.; Scagliola, C.

    2004-01-01

    A simple procedure for cursive word oversegmentation is presented, which is based on the analysis of the handwritten profiles and on the extraction of ``white holes\\'\\'. It follows the policy of using simple rules on complex data and sophisticated rules on simpler data. Experimental results show

  17. Simple clamped connection for bamboo truss systems

    NARCIS (Netherlands)

    Blok, R.

    2016-01-01

    “How to make fast and simple tension connections for truss systems?” The Solution: The innovation is a connection that uses only widely available base components (boltsand threaded steel bars) and simple hand tools to install it. With a handsaw and aspanner, the bamboo stems can be combined into to

  18. Optimization in the utility maximization framework for conservation planning: a comparison of solution procedures in a study of multifunctional agriculture

    Science.gov (United States)

    Kreitler, Jason R.; Stoms, David M.; Davis, Frank W.

    2014-01-01

    Quantitative methods of spatial conservation prioritization have traditionally been applied to issues in conservation biology and reserve design, though their use in other types of natural resource management is growing. The utility maximization problem is one form of a covering problem where multiple criteria can represent the expected social benefits of conservation action. This approach allows flexibility with a problem formulation that is more general than typical reserve design problems, though the solution methods are very similar. However, few studies have addressed optimization in utility maximization problems for conservation planning, and the effect of solution procedure is largely unquantified. Therefore, this study mapped five criteria describing elements of multifunctional agriculture to determine a hypothetical conservation resource allocation plan for agricultural land conservation in the Central Valley of CA, USA. We compared solution procedures within the utility maximization framework to determine the difference between an open source integer programming approach and a greedy heuristic, and find gains from optimization of up to 12%. We also model land availability for conservation action as a stochastic process and determine the decline in total utility compared to the globally optimal set using both solution algorithms. Our results are comparable to other studies illustrating the benefits of optimization for different conservation planning problems, and highlight the importance of maximizing the effectiveness of limited funding for conservation and natural resource management.

  19. Cleaning UF membranes with simple and formulated solutions

    NARCIS (Netherlands)

    Levitsky, I.; Duek, A.; Naim, R.; Arkhangelsky, E.; Gitis, V.

    2012-01-01

    The ultrafiltration membranes fouled by proteins are typically cleaned by consecutive soaking in alkali, surfactant and oxidizing solutions. We combined all three chemicals into a formulated cleaning agent and examined its efficiency to restore the water flux without damaging the membrane or

  20. On the (In)Validity of Tests of Simple Mediation: Threats and Solutions

    Science.gov (United States)

    Pek, Jolynn; Hoyle, Rick H.

    2015-01-01

    Mediation analysis is a popular framework for identifying underlying mechanisms in social psychology. In the context of simple mediation, we review and discuss the implications of three facets of mediation analysis: (a) conceptualization of the relations between the variables, (b) statistical approaches, and (c) relevant elements of design. We also highlight the issue of equivalent models that are inherent in simple mediation. The extent to which results are meaningful stem directly from choices regarding these three facets of mediation analysis. We conclude by discussing how mediation analysis can be better applied to examine causal processes, highlight the limits of simple mediation, and make recommendations for better practice. PMID:26985234

  1. Diffusion of aqueous solutions of ionic, zwitterionic, and polar solutes

    Science.gov (United States)

    Teng, Xiaojing; Huang, Qi; Dharmawardhana, Chamila Chathuranga; Ichiye, Toshiko

    2018-06-01

    The properties of aqueous solutions of ionic, zwitterionic, and polar solutes are of interest to many fields. For instance, one of the many anomalous properties of aqueous solutions is the behavior of water diffusion in different monovalent salt solutions. In addition, solutes can affect the stabilities of macromolecules such as proteins in aqueous solution. Here, the diffusivities of aqueous solutions of sodium chloride, potassium chloride, tri-methylamine oxide (TMAO), urea, and TMAO-urea are examined in molecular dynamics simulations. The decrease in the diffusivity of water with the concentration of simple ions and urea can be described by a simple model in which the water molecules hydrogen bonded to the solutes are considered to diffuse at the same rate as the solutes, while the remainder of the water molecules are considered to be bulk and diffuse at almost the same rate as pure water. On the other hand, the decrease in the diffusivity of water with the concentration of TMAO is apparently affected by a decrease in the diffusion rate of the bulk water molecules in addition to the decrease due to the water molecules hydrogen bonded to TMAO. In other words, TMAO enhances the viscosity of water, while urea barely affects it. Overall, this separation of water molecules into those that are hydrogen bonded to solute and those that are bulk can provide a useful means of understanding the short- and long-range effects of solutes on water.

  2. Analytical solution to DGLAP integro-differential equation in a simple toy-model with a fixed gauge coupling

    Energy Technology Data Exchange (ETDEWEB)

    Alvarez, Gustavo [Hamburg Univ. (Germany). 2. Inst. fuer Theoretische Physik; Concepcion Univ. (Chile). Dept. de Fisica; Cvetic, Gorazd [Univ. Tecnica Federico Santa Maria, Valparaiso (Chile). Dept. de Fisica; Kniehl, Bernd A. [Hamburg Univ. (Germany). 2. Inst. fuer Theoretische Physik; Kondrashuk, Igor [Univ. del Bio-Bio, Chillan (Chile). Grupo de Matematica Aplicada; Univ. del Bio-Bio, Chillan (Chile). Grupo de Fisica de Altas Energias; Parra-Ferrada, Ivan [Talca Univ. (Chile). Inst. de Matematica y Fisica

    2016-11-15

    We consider a simple model for QCD dynamics in which DGLAP integro-differential equation may be solved analytically. This is a gauge model which possesses dominant evolution of gauge boson (gluon) distribution and in which the gauge coupling does not run. This may be N=4 supersymmetric gauge theory with softly broken supersymmetry, other finite supersymmetric gauge theory with lower level of supersymmetry, or topological Chern-Simons field theories. We maintain only one term in the splitting function of unintegrated gluon distribution and solve DGLAP analytically for this simplified splitting function. The solution is found by use of the Cauchy integral formula. The solution restricts form of the unintegrated gluon distribution as function of transfer momentum and of Bjorken x. Then we consider an almost realistic splitting function of unintegrated gluon distribution as an input to DGLAP equation and solve it by the same method which we have developed to solve DGLAP equation for the toy-model. We study a result obtained for the realistic gluon distribution and find a singular Bessel-like behaviour in the vicinity of the point x=0 and a smooth behaviour in the vicinity of the point x=1.

  3. Simple Protein Modification Using Zwitterionic Polymer to Mitigate the Bioactivity Loss of Conjugated Insulin.

    Science.gov (United States)

    Xie, Jinbing; Lu, Yang; Wang, Wei; Zhu, Hui; Wang, Zhigang; Cao, Zhiqiang

    2017-06-01

    Polymer-protein conjugation has been extensively explored toward a better protein drug with improved pharmacokinetics. However, a major problem with polymer-protein conjugation is that the polymers drastically reduce the bioactivity of the modified protein. There is no perfect solution to prevent the bioactivity loss, no matter the polymer is conjugated in a non-site specific way, or a more complex site-specific procedure. Here the authors report for the first time that when zwitterionic carboxybetaine polymer (PCB) is conjugated to insulin through simple conventional coupling chemistry. The resulting PCB-insulin does not show a significant reduction of in vitro bioactivity. The obtained PCB-insulin shows two significant advantages as a novel pharmaceutical agent. First, its therapeutic performance is remarkable. For PCB-insulin, there is a 24% increase of in vivo pharmacological activity of lowering blood glucose compared with native insulin. Such uncommonly seen increase has rarely been reported and is expected to be due to both the improved pharmacokinetics and retained bioactivity of PCB-insulin. Second, the production is simple from manufacturing standpoints. Conjugation procedure involves only one-step coupling reaction without complex site-specific linkage technique. The synthesized PCB-insulin conjugates do not require chromatographic separation to purify and obtain particular isoforms. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Structural and computational aspects of simple and influence games

    OpenAIRE

    Riquelme Csori, Fabián

    2014-01-01

    Simple games are a fundamental class of cooperative games. They have a huge relevance in several areas of computer science, social sciences and discrete applied mathematics. The algorithmic and computational complexity aspects of simple games have been gaining notoriety in the recent years. In this thesis we review different computational problems related to properties, parameters, and solution concepts of simple games. We consider different forms of representation of simple games, regular...

  5. Solitary wave solutions of the fourth order Boussinesq equation through the exp(-Ф(η))-expansion method.

    Science.gov (United States)

    Akbar, M Ali; Hj Mohd Ali, Norhashidah

    2014-01-01

    The exp(-Ф(η))-expansion method is an ascending method for obtaining exact and solitary wave solutions for nonlinear evolution equations. In this article, we implement the exp(-Ф(η))-expansion method to build solitary wave solutions to the fourth order Boussinesq equation. The procedure is simple, direct and useful with the help of computer algebra. By using this method, we obtain solitary wave solutions in terms of the hyperbolic functions, the trigonometric functions and elementary functions. The results show that the exp(-Ф(η))-expansion method is straightforward and effective mathematical tool for the treatment of nonlinear evolution equations in mathematical physics and engineering. 35C07; 35C08; 35P99.

  6. Estimates of Inequality Indices Based on Simple Random, Ranked Set, and Systematic Sampling

    OpenAIRE

    Bansal, Pooja; Arora, Sangeeta; Mahajan, Kalpana K.

    2013-01-01

    Gini index, Bonferroni index, and Absolute Lorenz index are some popular indices of inequality showing different features of inequality measurement. In general simple random sampling procedure is commonly used to estimate the inequality indices and their related inference. The key condition that the samples must be drawn via simple random sampling procedure though makes calculations much simpler but this assumption is often violated in practice as the data does not always yield simple random ...

  7. A procedure to create isoconcentration surfaces in low-chemical-partitioning, high-solute alloys

    International Nuclear Information System (INIS)

    Hornbuckle, B.C.; Kapoor, M.; Thompson, G.B.

    2015-01-01

    A proximity histogram or proxigram is the prevailing technique of calculating 3D composition profiles of a second phase in atom probe tomography. The second phase in the reconstruction is delineated by creating an isoconcentration surface, i.e. the precipitate–matrix interface. The 3D composition profile is then calculated with respect to this user-defined isoconcentration surface. Hence, the selection of the correct isoconcentration surface is critical. In general, the preliminary selection of an isoconcentration value is guided by the visual observation of a chemically partitioned second phase. However, in low-chemical -partitioning systems, such a visual guide is absent. The lack of a priori composition information of the precipitate phase may further confound the issue. This paper presents a methodology of selecting an appropriate elemental species and subsequently obtaining an isoconcentration value to create an accurate isoconcentration surface that will act as the precipitate–matrix interface. We use the H-phase precipitate in the Ni–Ti–Hf shape memory alloy as our case study to illustrate the procedure. - Highlights: • A procedure for creating accurate isoconcentration surface for low-chemical-partitioning, high-solute alloys. • Determine the appropriate element to create the isosconcentration surface. • Subsequently identify the accurate isoconcentration value to create an isoconcentration surface.

  8. A simple solution for reducing artefacts due to conductive and dielectric effects in clinical magnetic resonance imaging at 3 T

    International Nuclear Information System (INIS)

    Sreenivas, M.; Lowry, M.; Gibbs, P.; Pickles, M.; Turnbull, L.W.

    2007-01-01

    The quality of imaging obtained at high magnetic field strengths can be degraded by various artefacts due to conductive and dielectric effects, which leads to loss of signal. Various methods have been described and used to improve the quality of the image affected by such artefacts. In this article, we describe the construction and use of a simple solution that can be used to diminish artefacts due to conductive and dielectric effects in clinical imaging at 3 T field strength and thereby improve the diagnostic quality of the images obtained

  9. A simple solution for reducing artefacts due to conductive and dielectric effects in clinical magnetic resonance imaging at 3 T

    Energy Technology Data Exchange (ETDEWEB)

    Sreenivas, M. [Department of Radiology (Yorkshire Deanery-East), Hull Royal Infirmary, Anlaby Road, Hull HU3 2JZ (United Kingdom)]. E-mail: aprilsreenivas@hotmail.com; Lowry, M. [Centre for Magnetic Resonance Investigations, University of Hull, Hull Royal Infirmary, Anlaby Road, 1PR, Hull HU3 2JZ (United Kingdom); Gibbs, P. [Centre for Magnetic Resonance Investigations, University of Hull, Hull Royal Infirmary, Anlaby Road, 1PR, Hull HU3 2JZ (United Kingdom); Pickles, M. [Centre for Magnetic Resonance Investigations, University of Hull, Hull Royal Infirmary, Anlaby Road, 1PR, Hull HU3 2JZ (United Kingdom); Turnbull, L.W. [Centre for Magnetic Resonance Investigations, University of Hull, Hull Royal Infirmary, Anlaby Road, 1PR, Hull HU3 2JZ (United Kingdom)

    2007-04-15

    The quality of imaging obtained at high magnetic field strengths can be degraded by various artefacts due to conductive and dielectric effects, which leads to loss of signal. Various methods have been described and used to improve the quality of the image affected by such artefacts. In this article, we describe the construction and use of a simple solution that can be used to diminish artefacts due to conductive and dielectric effects in clinical imaging at 3 T field strength and thereby improve the diagnostic quality of the images obtained.

  10. A Simple Technique of Supine Craniospinal Irradiation

    International Nuclear Information System (INIS)

    Munshi, Anusheel; Jalali, Rakesh

    2008-01-01

    We describe a simple procedure of craniospinal irradiation in supine position. The procedure was carried out with a 100-cm isocenter linear accelerator and compatible simulator. Treatment was with a 1 or 2 posteroanterior (PA)-directed spinal fields abutting lateral-directed cranial fields. Abutment of the fields was established by placement of markers on the neck of the patient, which provided a measure of the divergence of the spinal field. The precision and reproducibility of this technique, including the placement of junctions, appeared to be as good as for treatment in the prone position. The same could be verified with port films. We conclude that this new technique of supine craniospinal treatment is a simple and convenient alternative to traditional treatment in the prone position

  11. A Simple Harmonic Universe

    Energy Technology Data Exchange (ETDEWEB)

    Graham, Peter W.; /Stanford U., ITP; Horn, Bart; Kachru, Shamit; /Stanford U., ITP /SLAC; Rajendran, Surjeet; /Johns Hopkins U. /Stanford U., ITP; Torroba, Gonzalo; /Stanford U., ITP /SLAC

    2011-12-14

    We explore simple but novel bouncing solutions of general relativity that avoid singularities. These solutions require curvature k = +1, and are supported by a negative cosmological term and matter with -1 < w < -1 = 3. In the case of moderate bounces (where the ratio of the maximal scale factor a{sub +} to the minimal scale factor a{sub -} is {Omicron}(1)), the solutions are shown to be classically stable and cycle through an infinite set of bounces. For more extreme cases with large a{sub +} = a{sub -}, the solutions can still oscillate many times before classical instabilities take them out of the regime of validity of our approximations. In this regime, quantum particle production also leads eventually to a departure from the realm of validity of semiclassical general relativity, likely yielding a singular crunch. We briefly discuss possible applications of these models to realistic cosmology.

  12. Simple procedure for phase-space measurement and entanglement validation

    Science.gov (United States)

    Rundle, R. P.; Mills, P. W.; Tilma, Todd; Samson, J. H.; Everitt, M. J.

    2017-08-01

    It has recently been shown that it is possible to represent the complete quantum state of any system as a phase-space quasiprobability distribution (Wigner function) [Phys. Rev. Lett. 117, 180401 (2016), 10.1103/PhysRevLett.117.180401]. Such functions take the form of expectation values of an observable that has a direct analogy to displaced parity operators. In this work we give a procedure for the measurement of the Wigner function that should be applicable to any quantum system. We have applied our procedure to IBM's Quantum Experience five-qubit quantum processor to demonstrate that we can measure and generate the Wigner functions of two different Bell states as well as the five-qubit Greenberger-Horne-Zeilinger state. Because Wigner functions for spin systems are not unique, we define, compare, and contrast two distinct examples. We show how the use of these Wigner functions leads to an optimal method for quantum state analysis especially in the situation where specific characteristic features are of particular interest (such as for spin Schrödinger cat states). Furthermore we show that this analysis leads to straightforward, and potentially very efficient, entanglement test and state characterization methods.

  13. Incompressible Navier-Stokes and parabolized Navier-Stokes solution procedures and computational techniques

    Science.gov (United States)

    Rubin, S. G.

    1982-01-01

    Recent developments with finite-difference techniques are emphasized. The quotation marks reflect the fact that any finite discretization procedure can be included in this category. Many so-called finite element collocation and galerkin methods can be reproduced by appropriate forms of the differential equations and discretization formulas. Many of the difficulties encountered in early Navier-Stokes calculations were inherent not only in the choice of the different equations (accuracy), but also in the method of solution or choice of algorithm (convergence and stability, in the manner in which the dependent variables or discretized equations are related (coupling), in the manner that boundary conditions are applied, in the manner that the coordinate mesh is specified (grid generation), and finally, in recognizing that for many high Reynolds number flows not all contributions to the Navier-Stokes equations are necessarily of equal importance (parabolization, preferred direction, pressure interaction, asymptotic and mathematical character). It is these elements that are reviewed. Several Navier-Stokes and parabolized Navier-Stokes formulations are also presented.

  14. On the (In)Validity of Tests of Simple Mediation: Threats and Solutions

    OpenAIRE

    Pek, Jolynn; Hoyle, Rick H.

    2016-01-01

    Mediation analysis is a popular framework for identifying underlying mechanisms in social psychology. In the context of simple mediation, we review and discuss the implications of three facets of mediation analysis: (a) conceptualization of the relations between the variables, (b) statistical approaches, and (c) relevant elements of design. We also highlight the issue of equivalent models that are inherent in simple mediation. The extent to which results are meaningful stem directly from choi...

  15. A New Simple Approach for Entropy and Carnot Theorem

    International Nuclear Information System (INIS)

    Veliev, E. V.

    2004-01-01

    Entropy and Carnot theorem occupy central place in the typical Thermodynamics courses at the university level. In this work, we suggest a new simple approach for introducing the concept of entropy. Using simple procedure in TV plane, we proved that for reversible processes ∫dQ/T=0 and it is sufficient to define entropy. And also, using reversible processes in TS plane, we give an alternative simple proof for Carnot theorem

  16. A simple mathematical procedure to estimate heat flux in machining using measured surface temperature with infrared laser

    Directory of Open Access Journals (Sweden)

    Hocine Mzad

    2015-09-01

    Full Text Available Several techniques have been developed over time for the measurement of heat and the temperatures generated in various manufacturing processes and tribological applications. Each technique has its own advantages and disadvantages. The appropriate technique for temperature measurement depends on the application under consideration as well as the available tools for measurement. This paper presents a procedure for a simple and accurate determination of the time-varying heat flux at the workpiece–tool interface of three different metals under known cutting conditions. A portable infrared thermometer is used for surface temperature measurements. A spline smoothing interpolation of the surface temperature history enables to determine the local heat flux produced during stock removal. The measured temperature is represented by a third-order spline approximation. Nonetheless, the accuracy of polynomial interpolation depends on how close are the interpolated points; an increase in degree cannot be used to increase the accuracy. Although the data analysis is relatively complicated, the computing time is very small.

  17. A simple approximation of productivity scores of fuzzy production plans

    DEFF Research Database (Denmark)

    Hougaard, Jens Leth

    2005-01-01

    This paper suggests a simple approximation procedure for the assessment of productivity scores with respect to fuzzy production plans. The procedure has a clear economic interpretation and all the necessary calculations can be performed in a spreadsheet making it highly operational...

  18. EPR of gamma irradiated solid sucrose and UV spectra of its solution. An attempt for calibration of solid state/EPR dosimetry

    International Nuclear Information System (INIS)

    Yordanov, N.D.; Karakirova, Y.

    2007-01-01

    A simple new approach for independent calibration of solid state/EPR (SS/EPR) dosimetry system is reported. It is based on the fact that: (i) gamma-irradiation of solid sucrose (sugar) induces stable EPR detectable free radicals accompanied by UV detectable brown colour stable in the solid state and in solution; (ii) both the EPR intensity of gamma-irradiated solid sucrose and its solution UV absorbance linearly depend on the absorbed dose high energy radiation and may be independently used for dosimetric purpose; (iii) UV spectrometers are calibrated. The correlation between EPR response and absorbed dose radiation of solid sucrose and UV absorption of its solutions is used in the present communication for calibration purpose. The procedure of sucrose extraction from sucrose-paraffin dosimeters is described. The calibration procedure may be applied to any other (alanine, self-calibrated, etc.) SS/EPR dosimeters, simultaneously irradiated with sucrose

  19. A procedure to construct exact solutions of nonlinear evolution ...

    Indian Academy of Sciences (India)

    Exact solutions; the functional variable method; nonlinear wave equations. PACS Nos 02.30. ... computer science, directly searching for solutions of nonlinear differential equations has become more and ... Right after this pioneer work, this ...

  20. Spectrophotometric determination of copper in alkaline solutions and evaluation of some hydroxy-substituted 1,10-phenanthrolines as chromogenic reagents.

    Science.gov (United States)

    Dunbar, W E; Schilt, A A

    1972-09-01

    Seven new hydroxy-substituted 1,10-phenanthroline derivatives have been evaluated as chromogenic reagents for the determination of copper in strongly alkaline solution. The most sensitive of these, 2,9-dimethyl-4,7-dihydroxy-1,10-phenanthroline, has proven to be highly effective in a simple, rapid procedure for determining trace amounts of copper in sodium hydroxide, potassium carbonate, sodium phosphate or ammonium hydroxide.

  1. A Simple Preparation Method for Diphosphoimidazole

    DEFF Research Database (Denmark)

    Rosenberg, T.

    1964-01-01

    A simple method for the preparation of diphosphoimidazole is presented that involves direct phosphorylation of imidazole by phosphorus oxychloride in alkaline aqueous solution. Details are given on the use of diphosphoimidazole in preparing sodium phosphoramidate and certain phosphorylated amino...

  2. Simple Perturbation Example for Quantum Chemistry.

    Science.gov (United States)

    Goodfriend, P. L.

    1985-01-01

    Presents a simple example that illustrates various aspects of the Rayleigh-Schrodinger perturbation theory. The example is a particularly good one because it is straightforward and can be compared with both the exact solution and with experimental data. (JN)

  3. An exact solution procedure for multi-item two-echelon spare parts inventory control problem with batch ordering in the central warehouse

    NARCIS (Netherlands)

    Topan, E.; Bayindir, Z.P.; Tan, T.

    2009-01-01

    We consider a multi-item two-echelon inventory system in which the central warehouse operates under a (Q; R) policy, and the local warehouses implement basestock policy. An exact solution procedure is proposed to find the inventory control policy parameters that minimize the system-wide inventory

  4. A simple procedure to estimate reactivity with good noise filtering characteristics

    International Nuclear Information System (INIS)

    Shimazu, Yoichiro

    2014-01-01

    Highlights: • A new and simple on-line reactivity estimation method is proposed. • The estimator has robust noise filtering characteristics. • The noise filtering is equivalent to those of conventional reactivity meters. • The new estimator eliminates the burden of selecting optimum filter constants. • The new estimation performance is assessed without and with measurement noise. - Abstract: A new and simple on-line reactivity estimation method is proposed. The estimator has robust noise filtering characteristics without the use of complex filters. The noise filtering capability is equivalent to or better than that of a conventional estimator based on Inverse Point Kinetics (IPK). The new estimator can also eliminate the burden of selecting optimum filter time constants, such as would be required for the IPK-based estimator, or noise covariance matrices, which are needed if the extended Kalman filter (EKF) technique is used. In this paper, the new estimation method is introduced and its performance assessed without and with measurement noise

  5. Colostomy is a simple and effective procedure for severe chronic radiation proctitis.

    Science.gov (United States)

    Yuan, Zi-Xu; Ma, Teng-Hui; Wang, Huai-Ming; Zhong, Qing-Hua; Yu, Xi-Hu; Qin, Qi-Yuan; Wang, Jian-Ping; Wang, Lei

    2016-06-28

    To assess the efficacy and safety of diverting colostomy in treating severe hemorrhagic chronic radiation proctitis (CRP). Patients with severe hemorrhagic CRP who were admitted from 2008 to 2014 were enrolled into this study. All CRP patients were diagnosed by a combination of pelvic radiation history, clinical rectal bleeding, and endoscopic findings. Inclusion criteria were CRP patients with refractory bleeding with moderate to severe anemia with a hemoglobin level colostomy, while the control group included patients who received conservative treatment. The remission of bleeding was defined as complete cessation or only occasional bleeding that needed no further treatment. The primary outcome was bleeding remission at 6 mo after treatment. Quality of life before treatment and at follow-up was evaluated according to EORTC QLQ C30. Severe CRP complications were recorded during follow-up. Forty-seven consecutive patients were enrolled, including 22 in the colostomy group and 27 in the conservative treatment group. When compared to conservative treatment, colostomy obtained a higher rate of bleeding remission (94% vs 12%), especially in control of transfusion-dependent bleeding (100% vs 0%), and offered a better control of refractory perianal pain (100% vs 0%), and a lower score of bleeding (P colostomy achieved better remission of both moderate bleeding (100% vs 21.5%, P = 0.002) and severe bleeding (100% vs 0%, P colostomy, which included global health, function, and symptoms, but it was not improved in the control group. Pathological evaluation after colostomy found diffused chronic inflammation cells, and massive fibrosis collagen depositions under the rectal wall, which revealed potential fibrosis formation. Diverting colostomy is a simple, effective and safe procedure for severe hemorrhagic CRP. Colostomy can improve quality of life and reduce serious complications secondary to radiotherapy.

  6. Development of rapid and simple method for DNA extraction from cannabis resin based on the evaluation of relative PCR amplification ability.

    Science.gov (United States)

    Yamamuro, Tadashi; Iwata, Yuko T; Segawa, Hiroki; Kuwayama, Kenji; Tsujikawa, Kenji; Kanamori, Tatsuyuki; Inoue, Hiroyuki

    2018-04-04

    In recent years, analysis of cannabis DNA has been increasingly used in forensic drug tests. However, in the case of cannabis resin, a processed marijuana product, complicated procedures are required for the extraction of clean DNA, as the presence of various impurities inhibits PCR amplification. Therefore, in this study, we attempted to identify the factors that would allow quick and simple DNA extraction from cannabis resin with a commercially available kit. We also constructed a simple assay system for comparing relative amplification efficiencies by end-point PCR and used it to evaluate the purity of the obtained DNA solutions. For extraction with a kit that contains a silica column, reducing the starting amount of resin, using the residue remaining after methanol extraction, dilution of the final solution, extraction with an equal amount of powdered activated carbon or an excess amount of polyvinylpolypyrrolidone, and the addition of an appropriate amount of polyvinylpyrrolidone to the solution after extraction were effective measures that improved amplification efficiency. Furthermore, the use of the most rapid alkaline extraction kit combined with the addition of powdered activated carbon allowed obtaining DNA solutions with sufficient amplification efficiency in about 10min. These findings should be useful for routine DNA analysis of cannabis resin during forensic examination. Copyright © 2018 Elsevier B.V. All rights reserved.

  7. Ketamine. A solution to procedural pain in burned children.

    Science.gov (United States)

    Groeneveld, A; Inkson, T

    1992-09-01

    Our experience has shown ketamine to be a safe and effective method of providing pain relief during specific procedures in burned children. It renders high doses of narcotics unnecessary and offers children the benefit of general anesthesia without the requirement of endotracheal intubation and a trip to the operating room. The response of parents and staff to the use of ketamine has been positive. Parents often experience feelings of guilt following injury to a child and are eager to employ methods that reduce their child's pain. So far, no parent has refused the administration of ketamine; some have even asked that it be used during subsequent procedures on their child. With adequate pre-procedure teaching, parents are prepared for the possible occurrence of emergent reactions and can assist in reorienting the child during recovery. Staff have found that the stress of doing painful procedures on children is reduced when ketamine is used. The procedures tend to be quicker and the predicament of working on a screaming, agitated child is eliminated. At the same time, nursing staff have had to get used to the nystagmic gaze of the children and accept that these patients are truly anesthetized even though they might move and talk. Despite the success we and others have had with ketamine, several questions about its use in burn patients remain unanswered. The literature does not answer such questions as: Which nursing measures reduce the incidence of emergent reactions? How many ketamine anesthetics can safely be administered to one individual? How does the frequency of administration relate to tolerance in a burn patient? Are there detrimental effects of frequent or long-term use? Clearly, an understanding of these questions is necessary to determine the safe boundaries of ketamine use in burn patients. Ketamine is not a panacea for the problem of pain in burned children. But it is one means of managing procedural pain, which is, after all, a significant clinical

  8. The development of simple field based procedures for extraction of ...

    African Journals Online (AJOL)

    Field and laboratory experiments were conducted to develop procedures for extracting volatiles from the vine of Adenia cissampeloides which could effect the highest yield at the lowest extraction costs and also could be produced at the cottage industry level. The participatory rural appraisal technique was used to ensure ...

  9. Numerical solutions of multi-dimensional solidification/melting problems by the dual reciprocity boundary element method

    International Nuclear Information System (INIS)

    Jo, Jong Chull; Shin, Won Ky

    1997-01-01

    This paper presents an effective and simple procedure for the simulation of the motion of the solid-liquid interfacial boundary and the transient temperature field during phase change process. To accomplish this purpose, an iterative implicit solution algorithm has been developed by employing the dual reciprocity boundary element method. The dual reciprocity boundary element approach provided in this paper is much simpler than the usual boundary element method applying a reciprocity principle and an available technique for dealing with domain integral of boundary element formulation simultaneously. The effectiveness of the present analysis method have been illustrated through comparisons of the calculation results of an example with its semi-analytical or other numerical solutions where available

  10. Weyl functions, the inverse problem and special solutions for the system auxiliary to the nonlinear optics equation

    International Nuclear Information System (INIS)

    Sakhnovich, Alexander

    2008-01-01

    A Borg–Marchenko-type uniqueness theorem (in terms of the Weyl function) is obtained here for the system auxiliary to the N-wave equation. A procedure to solve the inverse problem is used for this purpose. The asymptotic condition on the Weyl function, under which the inverse problem is uniquely solvable, is completed by a new and simple sufficient condition on the potential, which implies this asymptotic condition. The evolution of the Weyl function is discussed and the solution of an initial-boundary-value problem for the N-wave equation follows. Explicit solutions of an inverse problem are obtained. The system with a shifted argument is treated

  11. A simple and effective approach to prepare injectable macroporous calcium phosphate cement for bone repair: Syringe-foaming using a viscous hydrophilic polymeric solution.

    Science.gov (United States)

    Zhang, Jingtao; Liu, Weizhen; Gauthier, Olivier; Sourice, Sophie; Pilet, Paul; Rethore, Gildas; Khairoun, Khalid; Bouler, Jean-Michel; Tancret, Franck; Weiss, Pierre

    2016-02-01

    In this study, we propose a simple and effective strategy to prepare injectable macroporous calcium phosphate cements (CPCs) by syringe-foaming via hydrophilic viscous polymeric solution, such as using silanized-hydroxypropyl methylcellulose (Si-HPMC) as a foaming agent. The Si-HPMC foamed CPCs demonstrate excellent handling properties such as injectability and cohesion. After hardening the foamed CPCs possess hierarchical macropores and their mechanical properties (Young's modulus and compressive strength) are comparable to those of cancellous bone. Moreover, a preliminary in vivo study in the distal femoral sites of rabbits was conducted to evaluate the biofunctionality of this injectable macroporous CPC. The evidence of newly formed bone in the central zone of implantation site indicates the feasibility and effectiveness of this foaming strategy that will have to be optimized by further extensive animal experiments. A major challenge in the design of biomaterial-based injectable bone substitutes is the development of cohesive, macroporous and self-setting calcium phosphate cement (CPC) that enables rapid cell invasion with adequate initial mechanical properties without the use of complex processing and additives. Thus, we propose a simple and effective strategy to prepare injectable macroporous CPCs through syringe-foaming using a hydrophilic viscous polymeric solution (silanized-hydroxypropyl methylcellulose, Si-HPMC) as a foaming agent, that simultaneously meets all the aforementioned aims. Evidence from our in vivo studies shows the existence of newly formed bone within the implantation site, indicating the feasibility and effectiveness of this foaming strategy, which could be used in various CPC systems using other hydrophilic viscous polymeric solutions. Copyright © 2015 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  12. Singular perturbation solutions of steady-state Poisson-Nernst-Planck systems.

    Science.gov (United States)

    Wang, Xiang-Sheng; He, Dongdong; Wylie, Jonathan J; Huang, Huaxiong

    2014-02-01

    We study the Poisson-Nernst-Planck (PNP) system with an arbitrary number of ion species with arbitrary valences in the absence of fixed charges. Assuming point charges and that the Debye length is small relative to the domain size, we derive an asymptotic formula for the steady-state solution by matching outer and boundary layer solutions. The case of two ionic species has been extensively studied, the uniqueness of the solution has been proved, and an explicit expression for the solution has been obtained. However, the case of three or more ions has received significantly less attention. Previous work has indicated that the solution may be nonunique and that even obtaining numerical solutions is a difficult task since one must solve complicated systems of nonlinear equations. By adopting a methodology that preserves the symmetries of the PNP system, we show that determining the outer solution effectively reduces to solving a single scalar transcendental equation. Due to the simple form of the transcendental equation, it can be solved numerically in a straightforward manner. Our methodology thus provides a standard procedure for solving the PNP system and we illustrate this by solving some practical examples. Despite the fact that for three ions, previous studies have indicated that multiple solutions may exist, we show that all except for one of these solutions are unphysical and thereby prove the existence and uniqueness for the three-ion case.

  13. A simple and selective colorimetric mercury (II) sensing system based on chitosan stabilized gold nanoparticles and 2,6-pyridinedicarboxylic acid

    International Nuclear Information System (INIS)

    Tian, Kun; Siegel, Gene; Tiwari, Ashutosh

    2017-01-01

    The development of simple and cost-effective methods for the detection and treatment of Hg 2+ in the environment is an important area of research due to the serious health risk that Hg 2+ poses to humans. Colorimetric sensing based on the induced aggregation of nanoparticles is of great interest since it offers a low cost, simple, and relatively rapid procedure, making it perfect for on-site analysis. Herein we report the development of a simple colorimetric sensor for the selective detection and estimation of mercury ions in water, based on chitosan stabilized gold nanoparticles (AuNPs) and 2,6-pyridinedicarboxylic acid (PDA). In the presence of Hg 2+ , PDA induces the aggregation of AuNPs, causing the solution to change colors varying from red to blue, depending on the concentration of Hg 2+ . The formation of aggregated AuNPs in the presence of Hg 2+ was confirmed using transmission electron microscopy (TEM) and UV–Vis spectroscopy. The method exhibits linearity in the range of 300 nM to 5 μM and shows excellent selectivity towards Hg 2+ among seventeen different metal ions and was successfully applied for the detection of Hg 2+ in spiked river water samples. The developed technique is simple and superior to the existing techniques in that it allows detection of Hg 2+ using the naked eye and simple and rapid colorimetric analysis, which eliminates the need for sophisticated instruments and sample preparation methods. - Highlights: • A simple colorimetric method for detection of Hg 2+ in water was proposed. • Au nanoparticles and 2,6-pyridinedicarboxylic acid were used for sensing Hg 2+ . • Sensing mechanisms were demonstrated by TEM and UV–Visible measurements. • It showed the solution color changes from red to blue upon addition of Hg 2+ . • The method selectively detected Hg 2+ among seventeen different metal ions.

  14. Simple one-dimensional finite element algorithm with multi-dimensional capabilities

    International Nuclear Information System (INIS)

    Pepper, D.W.; Baker, A.J.

    1978-01-01

    The application of the finite element procedure for the solution of partial differential equations is gaining widespread acceptance. The ability of the finite element procedure to solve problems which are arbitrarily shaped as well as the alleviation of boundary condition problems is well known. By using local interpolation functionals over each subdomain, or element, a set of linearized algebraic equations are obtained which can be solved using any direct, iterative, or inverse numerical technique. Subsequent use of an explicit or implicit integration procedure permits closure of the solution over the global domain

  15. Processing Solutions for Big Data in Astronomy

    Science.gov (United States)

    Fillatre, L.; Lepiller, D.

    2016-09-01

    This paper gives a simple introduction to processing solutions applied to massive amounts of data. It proposes a general presentation of the Big Data paradigm. The Hadoop framework, which is considered as the pioneering processing solution for Big Data, is described together with YARN, the integrated Hadoop tool for resource allocation. This paper also presents the main tools for the management of both the storage (NoSQL solutions) and computing capacities (MapReduce parallel processing schema) of a cluster of machines. Finally, more recent processing solutions like Spark are discussed. Big Data frameworks are now able to run complex applications while keeping the programming simple and greatly improving the computing speed.

  16. Function Allocation in Complex Socio-Technical Systems: Procedure usage in nuclear power and the Context Analysis Method for Identifying Design Solutions (CAMIDS) Model

    Science.gov (United States)

    Schmitt, Kara Anne

    This research aims to prove that strict adherence to procedures and rigid compliance to process in the US Nuclear Industry may not prevent incidents or increase safety. According to the Institute of Nuclear Power Operations, the nuclear power industry has seen a recent rise in events, and this research claims that a contributing factor to this rise is organizational, cultural, and based on peoples overreliance on procedures and policy. Understanding the proper balance of function allocation, automation and human decision-making is imperative to creating a nuclear power plant that is safe, efficient, and reliable. This research claims that new generations of operators are less engaged and thinking because they have been instructed to follow procedures to a fault. According to operators, they were once to know the plant and its interrelations, but organizationally more importance is now put on following procedure and policy. Literature reviews were performed, experts were questioned, and a model for context analysis was developed. The Context Analysis Method for Identifying Design Solutions (CAMIDS) Model was created, verified and validated through both peer review and application in real world scenarios in active nuclear power plant simulators. These experiments supported the claim that strict adherence and rigid compliance to procedures may not increase safety by studying the industry's propensity for following incorrect procedures, and when it directly affects the outcome of safety or security of the plant. The findings of this research indicate that the younger generations of operators rely highly on procedures, and the organizational pressures of required compliance to procedures may lead to incidents within the plant because operators feel pressured into following the rules and policy above performing the correct actions in a timely manner. The findings support computer based procedures, efficient alarm systems, and skill of the craft matrices. The solution to

  17. A simple automated procedure for thiol measurement in human serum samples Procedimento automatizado simples para determinação de tióis em amostras de soro humano

    Directory of Open Access Journals (Sweden)

    Carolina M. da Costa

    2006-10-01

    Full Text Available Thiol groups have been described as the main responsible for antioxidative effects of plasmatic proteins. Also, thiol serum levels have shown a positive correlation with total antioxidant capacity (TAC in many studies. Measurement of TAC by substract oxidation-based methods have been widely used as a reference to measure antioxidant status; however, in many cases these methods are inexact or imprecise, usually when performed by manual procedures. In this paper we describe a simple automated procedure for the determination of total thiols in serum, which was based on Ellman’s method. It was correlated with several markers of oxidative/antioxidative status, such as TAC and thiobarbituric acid reactive substance test (TBARs. Serum thiol levels were correlated positively with TAC (r = 0.298, p Os tióis são descritos como os principais responsáveis pelos efeitos antioxidantes das proteínas plasmáticas. Além disso, diversos estudos mostram uma correlação positiva entre os níveis séricos de tióis e a capacidade antioxidante total (CAT. A medida da CAT por métodos baseados na oxidação de substratos tem sido amplamente usada como referência na estimativa da capacidade antioxidante em amostras biológicas; porém, em muitos casos esses métodos são inexatos e imprecisos, principalmente quando realizados por procedimentos não-automatizados. Neste artigo descrevemos um procedimento automatizado simples para a determinação de tióis totais no soro, com base no conhecido método de Ellman. A dosagem dos tióis foi correlacionada com diversos marcadores da capacidade oxidante/antioxidante, como a CAT, o teste das substâncias reativas ao ácido tiobarbitúrico (TBARs e os níveis de peróxidos totais. Os tióis correlacionaram-se positivamente com a CAT (r = 0,298; p < 0,001 e negativamente com os níveis de TBARs (r = - 0,330; p < 0,001. O procedimento aqui descrito para a dosagem de tióis pode ser uma ferramenta importante na medida da

  18. Comparison of transition-matrix sampling procedures

    DEFF Research Database (Denmark)

    Yevick, D.; Reimer, M.; Tromborg, Bjarne

    2009-01-01

    We compare the accuracy of the multicanonical procedure with that of transition-matrix models of static and dynamic communication system properties incorporating different acceptance rules. We find that for appropriate ranges of the underlying numerical parameters, algorithmically simple yet high...... accurate procedures can be employed in place of the standard multicanonical sampling algorithm....

  19. Matching procedure for the sixth Painleve equation

    International Nuclear Information System (INIS)

    Guzzetti, Davide

    2006-01-01

    In the framework of the isomonodromy deformation method, we present a constructive procedure to obtain the critical behaviour of Painleve VI transcendents and solve the connection problem. This procedure yields two- and one-parameter families of solutions, including trigonometric and logarithmic behaviours, and three classes of solutions with Taylor expansion at a critical point

  20. Use of a Nasal Speculum for Chest-Drain Insertion: A Simple Technique

    OpenAIRE

    Saxena, Pankaj; Konstantinov, Igor E.; Newman, Mark A.J.

    2006-01-01

    Tube thoracostomy is a very commonly performed procedure in cardiothoracic surgery. Insertion of a chest drain requires expertise to minimize complications. We describe a simple technique of using a nasal speculum to perform this procedure.

  1. Exploring item and higher order factor structure with the Schmid-Leiman solution: syntax codes for SPSS and SAS.

    Science.gov (United States)

    Wolff, Hans-Georg; Preising, Katja

    2005-02-01

    To ease the interpretation of higher order factor analysis, the direct relationships between variables and higher order factors may be calculated by the Schmid-Leiman solution (SLS; Schmid & Leiman, 1957). This simple transformation of higher order factor analysis orthogonalizes first-order and higher order factors and thereby allows the interpretation of the relative impact of factor levels on variables. The Schmid-Leiman solution may also be used to facilitate theorizing and scale development. The rationale for the procedure is presented, supplemented by syntax codes for SPSS and SAS, since the transformation is not part of most statistical programs. Syntax codes may also be downloaded from www.psychonomic.org/archive/.

  2. A new and inexpensive non-bit-for-bit solution reproducibility test based on time step convergence (TSC1.0)

    Science.gov (United States)

    Wan, Hui; Zhang, Kai; Rasch, Philip J.; Singh, Balwinder; Chen, Xingyuan; Edwards, Jim

    2017-02-01

    A test procedure is proposed for identifying numerically significant solution changes in evolution equations used in atmospheric models. The test issues a fail signal when any code modifications or computing environment changes lead to solution differences that exceed the known time step sensitivity of the reference model. Initial evidence is provided using the Community Atmosphere Model (CAM) version 5.3 that the proposed procedure can be used to distinguish rounding-level solution changes from impacts of compiler optimization or parameter perturbation, which are known to cause substantial differences in the simulated climate. The test is not exhaustive since it does not detect issues associated with diagnostic calculations that do not feedback to the model state variables. Nevertheless, it provides a practical and objective way to assess the significance of solution changes. The short simulation length implies low computational cost. The independence between ensemble members allows for parallel execution of all simulations, thus facilitating fast turnaround. The new method is simple to implement since it does not require any code modifications. We expect that the same methodology can be used for any geophysical model to which the concept of time step convergence is applicable.

  3. A simple and rapid method for the determination of iodine in rice samples by radiochemical neutron activation analysis

    International Nuclear Information System (INIS)

    Takagi, Hiroyuki; Kimura, Toshimasa; Iwashima, Kiyoshi; Yamagata, Noboru.

    1983-01-01

    A simple and rapid method has been developed for the determination of iodine in rice samples by radiochemical neutron activation analysis. Irradiated rice powder was decomposed together with an iodide carrier solution containing I-131 on heating in a sodium hypochlorite solution. After decomposition, the solution was acidified with hydrochloric acid, and the insoluble residue was filtered off. To the filtrate sodium sulfite solution and palladium chloride solution were added, and the precipitate of palladium iodide was separated with a glass fiber filter paper. Iodine contents of rice were calculated from the peak areas under the 443 keV γ-ray of I-128 in the precipitate and comparative stand ard. Corrections for the chemical recovery were applied to them by means of the areas under the 365 keV γ-ray of I-131. This method was applied to the certified refe rece materials, IAEA wheat flour RM-V-5 and NBS orchard leaves SRM 1571. The results were in good agreement with the recommended values. Iodine contents of rice samples of two different origins in Japan were found to be of the order of 10 0 ng g -1 (dry weight base). The recovery of iodine in this procedure was about 80%. Decontamination factors for Mn, Cl, Na, and Br in the final fraction were 7 x 10 3 , 2 x 10 4 , 3 x 10 4 , and 2 x 10 2 , respectively. The time required for the chemical procedure was about 15 min, and the limit of determination was 0.7 ng of iodine in a sample of 1 g. (author)

  4. A simple and rapid method to estimate radiocesium in man

    International Nuclear Information System (INIS)

    Kindl, P.; Steger, F.

    1990-09-01

    A simple and rapid method for monitoring internal contamination of radiocesium in man was developed. This method is based on measurements of the γ-rays emitted from the muscular parts between the thights by a simple NaJ(Tl)-system. The experimental procedure, the calibration, the estimation of the body activity and results are explained and discussed. (Authors)

  5. The preparation of accelerator targets by the evaporation of acetate-organic solutions in the presence of NH3 gas

    International Nuclear Information System (INIS)

    Cai, S.Y.; Ghiorso, A.; Hoffman, D.C.

    1987-03-01

    The chemical methods described in this paper have been developed for preparation of isotopic targets for bombardment by accelerator-produced ions. Three systems are compared: nitrate-, chloride-, and acetate-organic solutions. The best method was found to be the metallic acetate-organic solution system, evaporated onto the substrate in the presence of ammonia gas. A detailed procedure is given for this method. The targets obtained by the acetate-organic solution system are uniform and adherent. The hydroxide forms fine crystals of good quality for target thicknesses from a few μg/cm 2 to several mg/cm 2 . Thicknesses up to 5 mg/cm 2 of Eu as the oxide were obtained by this method. The process is simple and fast. 18 refs., 1 tab

  6. A Simple and Rapid Complexometric Determination of Thallium(III ...

    African Journals Online (AJOL)

    A simple, rapid and selective complexometric method is proposed for the determination of thallium(III), using mercaptoethane(EtSH) as demasking agent. The sample solution containing Tl(III) is first complexed with excess EDTA and the surplus EDTA is removed by titration at pH 5–6 with zinc sulphate solution using ...

  7. Technology in rural transportation. Simple solution #6, traveler information on the internet

    Science.gov (United States)

    1997-01-01

    This application was identified as a promising rural Intelligent Transportation Systems (ITS) solution under a project sponsored by the Federal Highway Administration (FHWA) and the ENTERPRISE program. This summary describes the solution as well as o...

  8. FROM COMPLEX EVOLVING TO SIMPLE: CURRENT REVISIONAL AND ENDOSCOPIC PROCEDURES FOLLOWING BARIATRIC SURGERY.

    Science.gov (United States)

    Zorron, Ricardo; Galvão-Neto, Manoel Passos; Campos, Josemberg; Branco, Alcides José; Sampaio, José; Junghans, Tido; Bothe, Claudia; Benzing, Christian; Krenzien, Felix

    Roux-en-Y gastric bypass (RYGB) is a standard therapy in bariatric surgery. Sleeve gastrectomy and gastric banding, although with good results in the literature, are showing higher rates of treatment failure to reduce obesity-associated morbidity and body weight. Other problems after bariatric may occur, as band erosion, gastroesophageal reflux disease and might be refractory to medication. Therefore, a laparoscopic conversion to a RYGB can be an effective alternative, as long as specific indications for revision are fulfilled. The objective of this study was to analyse own and literature data on revisional bariatric procedures to evaluate best alternatives to current practice. Institutional experience and systematic review from the literature on revisional bariatric surgery. Endoscopic procedures are recently applied to ameliorate failure and complications of bariatric procedures. Therapy failure following RYGB occurs in up to 20%. Transoral outlet reduction is currently an alternative method to reduce the gastrojejunal anastomosis. The diameter and volume of sleeve gastrectomy can enlarge as well, which can be reduced by endoscopic full-thickness sutures longitudinally. Dumping syndrome and severe hypoglycemic episodes (neuroglycopenia) can be present in patients following RYGB. The hypoglycemic episodes have to be evaluated and usually can be treated conventionally. To avoid partial pancreatectomy or conversion to normal anatomy, a new laparoscopic approach with remnant gastric resection and jejunal interposition can be applied in non-responders alternatively. Hypoglycemic episodes are ameliorated while weight loss is sustained. Revisional and endoscopic procedures following bariatric surgery in patients with collateral symptomatic or treatment failure can be applied. Conventional non-surgical approaches should have been applied intensively before a revisional surgery will be indicated. Former complex surgical revisional procedures are evolving to less

  9. A simple versatile solution for collecting multidimensional clinical data based on the CakePHP web application framework.

    Science.gov (United States)

    Biermann, Martin

    2014-04-01

    Clinical trials aiming for regulatory approval of a therapeutic agent must be conducted according to Good Clinical Practice (GCP). Clinical Data Management Systems (CDMS) are specialized software solutions geared toward GCP-trials. They are however less suited for data management in small non-GCP research projects. For use in researcher-initiated non-GCP studies, we developed a client-server database application based on the public domain CakePHP framework. The underlying MySQL database uses a simple data model based on only five data tables. The graphical user interface can be run in any web browser inside the hospital network. Data are validated upon entry. Data contained in external database systems can be imported interactively. Data are automatically anonymized on import, and the key lists identifying the subjects being logged to a restricted part of the database. Data analysis is performed by separate statistics and analysis software connecting to the database via a generic Open Database Connectivity (ODBC) interface. Since its first pilot implementation in 2011, the solution has been applied to seven different clinical research projects covering different clinical problems in different organ systems such as cancer of the thyroid and the prostate glands. This paper shows how the adoption of a generic web application framework is a feasible, flexible, low-cost, and user-friendly way of managing multidimensional research data in researcher-initiated non-GCP clinical projects. Copyright © 2014 The Authors. Published by Elsevier Ireland Ltd.. All rights reserved.

  10. Wetting behavior of nonpolar nanotubes in simple dipolar liquids for varying nanotube diameter and solute-solvent interactions

    Energy Technology Data Exchange (ETDEWEB)

    Rana, Malay Kumar; Chandra, Amalendu, E-mail: amalen@iitk.ac.in [Department of Chemistry, Indian Institute of Technology Kanpur, Kanpur 208016 (India)

    2015-01-21

    Atomistic simulations of model nonpolar nanotubes in a Stockmayer liquid are carried out for varying nanotube diameter and nanotube-solvent interactions to investigate solvophobic interactions in generic dipolar solvents. We have considered model armchair type single-walled nonpolar nanotubes with increasing radii from (5,5) to (12,12). The interactions between solute and solvent molecules are modeled by the well-known Lennard-Jones and repulsive Weeks-Chandler-Andersen potentials. We have investigated the density profiles and microscopic arrangement of Stockmayer molecules, orientational profiles of their dipole vectors, time dependence of their occupation, and also the translational and rotational motion of solvent molecules in confined environments of the cylindrical nanopores and also in their external peripheral regions. The present results of structural and dynamical properties of Stockmayer molecules inside and near atomistically rough nonpolar surfaces including their wetting and dewetting behavior for varying interactions provide a more generic picture of solvophobic effects experienced by simple dipolar liquids without any specific interactions such as hydrogen bonds.

  11. Standardized methods for photography in procedural dermatology using simple equipment.

    Science.gov (United States)

    Hexsel, Doris; Hexsel, Camile L; Dal'Forno, Taciana; Schilling de Souza, Juliana; Silva, Aline F; Siega, Carolina

    2017-04-01

    Photography is an important tool in dermatology. Reproducing the settings of before photos after interventions allows more accurate evaluation of treatment outcomes. In this article, we describe standardized methods and tips to obtain photographs, both for clinical practice and research procedural dermatology, using common equipment. Standards for the studio, cameras, photographer, patients, and framing are presented in this article. © 2017 The International Society of Dermatology.

  12. The pulse radiolysis of aqueous solutions of simple RCN compounds

    International Nuclear Information System (INIS)

    Draganic, I.G.; Draganic, Z.D.; Markovic, V.M.

    1976-01-01

    Fast kinetic spectrophotometry was used to study the absorption spectra of short-living intermediates produced by reactions of RCN molecules with H, esub(aq) - and OH. The spectra were obtained on the microsecond time scale after an electron pulse from a Febetron 707 accelerator in aqueous solutions of the following compounds: hydrocyanic acid, acetonitrile, propionitrile, malononitrile and succinonitrile. It has been found that all intermediates absorb in the U.V. range (lamba 9 dm 3 mol -1 s -1 . In the presence of an efficient scavenger for hydroxyl radicals, the same transient spectra were registered in acid and neutral solutions suggesting that the protonations of esub(aq) - adducts of these RCN molecules were complete within a submicrosecond time interval. (author)

  13. Numerical solutions of multi-dimensional solidification/melting problems by the dual reciprocity boundary element method

    Energy Technology Data Exchange (ETDEWEB)

    Jo, Jong Chull; Shin, Won Ky [Korea Institute of Nuclear Safety, Taejon (Korea, Republic of)

    1998-12-31

    This paper presents an effective and simple procedure for the simulation of the motion of the solid-liquid interfacial boundary and the transient temperature field during phase change process. To accomplish this purpose, an iterative implicit solution algorithm has been developed by employing the dual reciprocity boundary element method. The dual reciprocity boundary element approach provided in this paper is much simpler than the usual boundary element method applying a reciprocity principle and an available technique for dealing with domain integral of boundary element formulation simultaneously. The effectiveness of the present analysis method have been illustrated through comparisons of the calculation results of an example with its semi-analytical or other numerical solutions where available. 22 refs., 3 figs. (Author)

  14. Numerical solutions of multi-dimensional solidification/melting problems by the dual reciprocity boundary element method

    Energy Technology Data Exchange (ETDEWEB)

    Jo, Jong Chull; Shin, Won Ky [Korea Institute of Nuclear Safety, Taejon (Korea, Republic of)

    1997-12-31

    This paper presents an effective and simple procedure for the simulation of the motion of the solid-liquid interfacial boundary and the transient temperature field during phase change process. To accomplish this purpose, an iterative implicit solution algorithm has been developed by employing the dual reciprocity boundary element method. The dual reciprocity boundary element approach provided in this paper is much simpler than the usual boundary element method applying a reciprocity principle and an available technique for dealing with domain integral of boundary element formulation simultaneously. The effectiveness of the present analysis method have been illustrated through comparisons of the calculation results of an example with its semi-analytical or other numerical solutions where available. 22 refs., 3 figs. (Author)

  15. Conception, definition, measuring procedure of grain size

    International Nuclear Information System (INIS)

    Yanagisawa, Kazuaki

    1976-12-01

    The conception, definition, measuring procedure of ''Grain Size'' were surveyed. A concept ''grain diameter'' was introduced after deriving a calculation formula for the grain diameter for using the Comparison (simple) and Intercept(detailed) procedure. As an example and putting into practice, the grain diameter determination was carried out by means of the Comparison procedure for a UO 2 pellet used in a densification experiment. (auth.)

  16. A simple procedure to model water level fluctuations in partially inundated wetlands

    NARCIS (Netherlands)

    Spieksma, JFM; Schouwenaars, JM

    When modelling groundwater behaviour in wetlands, there are specific problems related to the presence of open water in small-sized mosaic patterns. A simple quasi two-dimensional model to predict water level fluctuations in partially inundated wetlands is presented. In this model, the ratio between

  17. A simple technique for laparoscopic gastrostomy.

    Science.gov (United States)

    Murphy, C; Rosemurgy, A S; Albrink, M H; Carey, L C

    1992-05-01

    While endoscopically placed gastrostomy tubes are routinely simple, they are not always feasible. Endoscopic technique also does not uniformly secure the tube to the abdominal wall, which presents possible complications, including leakage, accidental early tube removal, intraperitoneal catheter migration and necrosis of the stomach or abdominal wall because of excessive traction. Presented herein is a technique that is rapid, simple and eliminates some of these potential complications. The technique is easily combined with other operative procedures, such as tracheostomy, is done under direct vision, can be performed quickly with intravenous sedation and local anesthetic and is a safe method of tube placement for enteral feeding or gastric decompression.

  18. Siemens IT solutions for power sector. PROFIT solutions

    International Nuclear Information System (INIS)

    Lunter, P.

    2004-01-01

    The cost reduction, flexibility and revenue increase, potential exploitation, productivity increase, and business opportunities exploitation - that is all what can be required in the races for the promonent positioning on the electricity power market. These requirements can be realized by the sophisticated IT solutions hand-tailored to the special requirements of the electric power producers and tradesmen. This approach makes it possible to achieve greater profit. Our solutions 'PROFIT Solutions', that are symbiosis of the most progressive information technologies and the power plant techniques of the company Siemens, satisfy submitted specifications in substantial measure. The system solutions 'PROFIT Solutions' comprise three solution groups: process, operation a business. The solutions of the group 'IT Process Solutions' increase flexibility and manoeuvrability of equipment, improve the efficiency and contribute to more economical operation of the power generation. Solutions 'IT Process Solutions' simplify and shorten the period of power cycles and conduce to higher labour productivity. Solutions group 'IT Process Solutions' approaches equipment to the market - supports the profit strategies, helps quickly and expertly to determine and predict hazards. The extension PROFIT Cockpit means the nuance to the solutions world 'PROFIT Solutions'. The survey about the whole installation is within reach at the simple touch of a button. It is possible to compile the total system part by part from single solutions 'PROFIT Solutions'. As a matter of fact all single parts can be interconnected with already existing solutions. Routines 'PROFIT Solutions' cooperate with all modern control systems. (author)

  19. Solution Tree Problem Solving Procedure for Engineering Analysis ...

    African Journals Online (AJOL)

    Illustrations are provided in the thermofluid engineering area to showcase the procedure's applications. This approach has proved to be a veritable tool for enhancing the problem-solving and computer algorithmic skills of engineering students, eliciting their curiosity, active participation and appreciation of the taught course.

  20. Dried blood spots and parallel artificial liquid membrane extraction-A simple combination of microsampling and microextraction.

    Science.gov (United States)

    Ask, Kristine Skoglund; Øiestad, Elisabeth Leere; Pedersen-Bjergaard, Stig; Gjelstad, Astrid

    2018-06-07

    In this paper, parallel artificial liquid membrane extraction (PALME) was used for the first time to clean-up dried blood spots (DBS) prior to ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS). Fundamental studies exploring amongst others desorption from the DBS in alkaline or acidic aqueous conditions, total extraction time and absolute recoveries were executed. Desorption and PALME were performed using a set of two 96-well plates, one of them housing the sample and the other comprising the supported liquid membrane (SLM) and the acceptor solution. In one procedure, amitriptyline and quetiapine (basic model analytes) were desorbed from the DBS using 250 μL of 10 mM sodium hydroxide solution (aqueous), and subsequently extracted through the SLM consisting of 4 μL of 1% trioctylamine in dodecyl acetate, and further into an acceptor solution consisting of 50 μL of 20 mM formic acid. In a second procedure, ketoprofen, fenoprofen, flurbiprofen, and ibuprofen (acidic model analytes) were desorbed from the DBS into 20 mM formic acid, extracted through an SLM with dihexyl ether, and further into an acceptor solution of 25 mM ammonia. Within 60 min of PALME, both basic and acidic model analytes were effectively desorbed from the DBS and extracted into the acceptor solution, which was injected directly into the analytical instrument. Recoveries between 63 and 85% for the six model analytes were obtained. PALME provided excellent clean-up from the DBS samples, and acceptor solutions were free from phospholipids. Linearity was obtained with r 2  > 0.99 for five of the six analytes. Accuracy, precision and UHPLC-MS/MS matrix effects were in accordance with the European Medicines Agency (EMA) guideline. Based on these experiments, PALME shows great potential for future processing of DBS in a short and simple way, and with the presented setup, up to 96 DBS can be processed within a total extraction time of 60

  1. A CLOSED-FORM SOLUTION PROCEDURE TO THE VIBRA TION ...

    African Journals Online (AJOL)

    into a set of linear algebraic equations that can be solved easily. The number of equations in the latter is double the number of modes used for the coordinate transformation. The modal coordinates cu:ethen easily determined making use of simple matrix algebra'. The technique presented is illustrated by imexample ...

  2. A family of analytical solutions of a nonlinear diffusion-convection equation

    Science.gov (United States)

    Hayek, Mohamed

    2018-01-01

    Despite its popularity in many engineering fields, the nonlinear diffusion-convection equation has no general analytical solutions. This work presents a family of closed-form analytical traveling wave solutions for the nonlinear diffusion-convection equation with power law nonlinearities. This kind of equations typically appears in nonlinear problems of flow and transport in porous media. The solutions that are addressed are simple and fully analytical. Three classes of analytical solutions are presented depending on the type of the nonlinear diffusion coefficient (increasing, decreasing or constant). It has shown that the structure of the traveling wave solution is strongly related to the diffusion term. The main advantage of the proposed solutions is that they are presented in a unified form contrary to existing solutions in the literature where the derivation of each solution depends on the specific values of the diffusion and convection parameters. The proposed closed-form solutions are simple to use, do not require any numerical implementation, and may be implemented in a simple spreadsheet. The analytical expressions are also useful to mathematically analyze the structure and properties of the solutions.

  3. A SIMPLE METHOD FOR THE EXTRACTION AND QUANTIFICATION OF PHOTOPIGMENTS FROM SYMBIODINIUM SPP.

    Science.gov (United States)

    John E. Rogers and Dragoslav Marcovich. Submitted. Simple Method for the Extraction and Quantification of Photopigments from Symbiodinium spp.. Limnol. Oceanogr. Methods. 19 p. (ERL,GB 1192). We have developed a simple, mild extraction procedure using methanol which, when...

  4. Development of a relatively cheap and simple automated separation system for a routine separation procedure based on extraction chromatography

    International Nuclear Information System (INIS)

    Petro Zoriy; Reinhold Flucht; Mechthild Burow; Peter Ostapczuk; Reinhard Lennartz; Myroslav Zoriy

    2010-01-01

    A robust analytical method has been developed in our laboratory for the separation of radionuclides by means of extraction chromatography using an automated separation system. The proposed method is both cheap and simple and provides the advantageous, rapid and accurate separation of the element of interest. The automated separation system enables a shorter separation time by maintaining a constant flow rate of solution and by avoiding clogging or bubbling in the chromatographic column. The present separation method was tested with two types of samples (water and urine) using UTEVA-, TRU- and Sr-specific resins for the separation of U, Th, Am, Pu and Sr. The total separation time for one radionuclide ranged from 60 to 100 min with the separation yield ranging from 68 to 98% depending on the elements separated. We used ICP-QMS, multi-low-level counter and alpha spectroscopy to measure the corresponding elements. (author)

  5. Simple solution

    Energy Technology Data Exchange (ETDEWEB)

    Wells, Paul

    2011-07-01

    FP Marangoni Inc., a Calgary-based service company, is presently the only oilfield service company in the world to have successfully established a way to blend vacuum and rig shakers to recapture oil-based mud, or any drilling fluid for that matter. Their VAC-Screen system is presently being utilized by several operators and has the potential to be used across a wide spectrum of drilling applications. The rotary vacuum dryer fluid recovery and cuttings drying system degraded the drilling cuttings that it processes and when this occurs, some of that stuff gets in the recovered fluid and it becomes very difficult to remove particles that are below 20 microns. Currently, VAC-Screen technology is running on about 20 rigs in Canada and the US, and more producers are showing a keen interest in using the technology. The VAC-Screen technology reduces costs and environmental impact. The main benefit is that the recovered fluid has no detrimental effects on the drilling fluid system. The going rental rate for the system is 30 per cent of the cost of competitive quality systems.

  6. Headspace-SPME-GC/MS as a simple cleanup tool for sensitive 2,6-diisopropylphenol analysis from lipid emulsions and adaptable to other matrices.

    Science.gov (United States)

    Pickl, Karin E; Adamek, Viktor; Gorges, Roland; Sinner, Frank M

    2011-07-15

    Due to increased regulatory requirements, the interaction of active pharmaceutical ingredients with various surfaces and solutions during production and storage is gaining interest in the pharmaceutical research field, in particular with respect to development of new formulations, new packaging material and the evaluation of cleaning processes. Experimental adsorption/absorption studies as well as the study of cleaning processes require sophisticated analytical methods with high sensitivity for the drug of interest. In the case of 2,6-diisopropylphenol - a small lipophilic drug which is typically formulated as lipid emulsion for intravenous injection - a highly sensitive method in the concentration range of μg/l suitable to be applied to a variety of different sample matrices including lipid emulsions is needed. We hereby present a headspace-solid phase microextraction (HS-SPME) approach as a simple cleanup procedure for sensitive 2,6-diisopropylphenol quantification from diverse matrices choosing a lipid emulsion as the most challenging matrix with regard to complexity. By combining the simple and straight forward HS-SPME sample pretreatment with an optimized GC-MS quantification method a robust and sensitive method for 2,6-diisopropylphenol was developed. This method shows excellent sensitivity in the low μg/l concentration range (5-200μg/l), good accuracy (94.8-98.8%) and precision (intraday-precision 0.1-9.2%, inter-day precision 2.0-7.7%). The method can be easily adapted to other, less complex, matrices such as water or swab extracts. Hence, the presented method holds the potential to serve as a single and simple analytical procedure for 2,6-diisopropylphenol analysis in various types of samples such as required in, e.g. adsorption/absorption studies which typically deal with a variety of different surfaces (steel, plastic, glass, etc.) and solutions/matrices including lipid emulsions. Copyright © 2011 Elsevier B.V. All rights reserved.

  7. Test procedure for anion exchange testing with Argonne 10-L solutions

    International Nuclear Information System (INIS)

    Compton, J.A.

    1995-01-01

    Four anion exchange resins will be tested to confirm that they will sorb and release plutonium from/to the appropriate solutions in the presence of other cations. Certain cations need to be removed from the test solutions to minimize adverse behavior in other processing equipment. The ion exchange resins will be tested using old laboratory solutions from Argonne National Laboratory; results will be compared to results from other similar processes for application to all plutonium solutions stored in the Plutonium Finishing Plant

  8. Local entropy as a measure for sampling solutions in constraint satisfaction problems

    International Nuclear Information System (INIS)

    Baldassi, Carlo; Ingrosso, Alessandro; Lucibello, Carlo; Saglietti, Luca; Zecchina, Riccardo

    2016-01-01

    We introduce a novel entropy-driven Monte Carlo (EdMC) strategy to efficiently sample solutions of random constraint satisfaction problems (CSPs). First, we extend a recent result that, using a large-deviation analysis, shows that the geometry of the space of solutions of the binary perceptron learning problem (a prototypical CSP), contains regions of very high-density of solutions. Despite being sub-dominant, these regions can be found by optimizing a local entropy measure. Building on these results, we construct a fast solver that relies exclusively on a local entropy estimate, and can be applied to general CSPs. We describe its performance not only for the perceptron learning problem but also for the random K-satisfiabilty problem (another prototypical CSP with a radically different structure), and show numerically that a simple zero-temperature Metropolis search in the smooth local entropy landscape can reach sub-dominant clusters of optimal solutions in a small number of steps, while standard Simulated Annealing either requires extremely long cooling procedures or just fails. We also discuss how the EdMC can heuristically be made even more efficient for the cases we studied. (paper: disordered systems, classical and quantum)

  9. A Comparison of Simple Methods to Incorporate Material Temperature Dependency in the Green's Function Method for Estimating Transient Thermal Stresses in Thick-Walled Power Plant Components.

    Science.gov (United States)

    Rouse, James; Hyde, Christopher

    2016-01-06

    The threat of thermal fatigue is an increasing concern for thermal power plant operators due to the increasing tendency to adopt "two-shifting" operating procedures. Thermal plants are likely to remain part of the energy portfolio for the foreseeable future and are under societal pressures to generate in a highly flexible and efficient manner. The Green's function method offers a flexible approach to determine reference elastic solutions for transient thermal stress problems. In order to simplify integration, it is often assumed that Green's functions (derived from finite element unit temperature step solutions) are temperature independent (this is not the case due to the temperature dependency of material parameters). The present work offers a simple method to approximate a material's temperature dependency using multiple reference unit solutions and an interpolation procedure. Thermal stress histories are predicted and compared for realistic temperature cycles using distinct techniques. The proposed interpolation method generally performs as well as (if not better) than the optimum single Green's function or the previously-suggested weighting function technique (particularly for large temperature increments). Coefficients of determination are typically above 0 . 96 , and peak stress differences between true and predicted datasets are always less than 10 MPa.

  10. A new force field including charge directionality for TMAO in aqueous solution

    Energy Technology Data Exchange (ETDEWEB)

    Usui, Kota; Nagata, Yuki, E-mail: sulpizi@uni-mainz.de, E-mail: nagata@mpip-mainz.mpg.de; Hunger, Johannes; Bonn, Mischa [Max Planck Institute for Polymer Research, Ackermannweg 10, 55128 Mainz (Germany); Sulpizi, Marialore, E-mail: sulpizi@uni-mainz.de, E-mail: nagata@mpip-mainz.mpg.de [Johannes Gutenberg University Mainz, Staudingerweg 7, 55099 Mainz (Germany)

    2016-08-14

    We propose a new force field for trimethylamine N-oxide (TMAO), which is designed to reproduce the long-lived and highly directional hydrogen bond between the TMAO oxygen (O{sub TMAO}) atom and surrounding water molecules. Based on the data obtained by ab initio molecular dynamics simulations, we introduce three dummy sites around O{sub TMAO} to mimic the O{sub TMAO} lone pairs and we migrate the negative charge on the O{sub TMAO} to the dummy sites. The force field model developed here improves both structural and dynamical properties of aqueous TMAO solutions. Moreover, it reproduces the experimentally observed dependence of viscosity upon increasing TMAO concentration quantitatively. The simple procedure of the force field construction makes it easy to implement in molecular dynamics simulation packages and makes it compatible with the existing biomolecular force fields. This paves the path for further investigation of protein-TMAO interaction in aqueous solutions.

  11. A new force field including charge directionality for TMAO in aqueous solution

    International Nuclear Information System (INIS)

    Usui, Kota; Nagata, Yuki; Hunger, Johannes; Bonn, Mischa; Sulpizi, Marialore

    2016-01-01

    We propose a new force field for trimethylamine N-oxide (TMAO), which is designed to reproduce the long-lived and highly directional hydrogen bond between the TMAO oxygen (O TMAO ) atom and surrounding water molecules. Based on the data obtained by ab initio molecular dynamics simulations, we introduce three dummy sites around O TMAO to mimic the O TMAO lone pairs and we migrate the negative charge on the O TMAO to the dummy sites. The force field model developed here improves both structural and dynamical properties of aqueous TMAO solutions. Moreover, it reproduces the experimentally observed dependence of viscosity upon increasing TMAO concentration quantitatively. The simple procedure of the force field construction makes it easy to implement in molecular dynamics simulation packages and makes it compatible with the existing biomolecular force fields. This paves the path for further investigation of protein-TMAO interaction in aqueous solutions.

  12. JJ Stent Removal under Ultrasound Guidance in Women: It is Simple and Safe.

    Science.gov (United States)

    Amer, Bernard; Gupta, Sandeep; Kanwar, Vijayendra S; Lodh, Bijit; Khumukcham, Somarendra; Akoijam, Kaku Singh

    2014-12-01

    With the increase in number of patients treated for urological problems with endoscopic procedures, the number of patients with JJ stent is also increasing. The amount of workload thus incurred multiplies, even to the point that, sometimes we waste more time in the operating room removing JJ stents than the actual endourological procedures. Here in our institute, we have devised a very simple and effective way of removing JJ stents in women and also determined the efficacy, safety and cost of JJ stent removal under ultrasound guidance in women in comparison to cystoscopic removal. Two hundred women attending the Department of Urology from July 2012 to July 2013 at RIMS hospital were randomly divided into two arms. One hundred women had their JJ stent removed with cystoscope and another 100 women had their JJ stent removed under ultrasound guidance using simple surgical tools available at the hospital. The primary comparative points were waiting time for operating room appointment date, cost of the procedure, time taken for the procedure, discomfort or pain felt by the patient and urethral injuries. In all the parameters, stent removal under ultrasound guidance was significantly better except for urethral injuries where both the procedures had similar outcomes. We concluded that JJ stent removal under ultrasound guidance in women was simple, effective and safe.

  13. A rapid sample decomposition procedure for bromo-heavies containing ferruginous material: determination of REEs and thorium by ICP-AES

    International Nuclear Information System (INIS)

    Khorge, C.R.; Murugesan, P.; Chakrapani, G.

    2013-01-01

    A rapid method of sample decomposition and dissolution for bromoform heavies is described for the determination of REEs and thorium by inductively coupled plasma- optical emission spectrometry. For application to geochemical exploration to achieve the high sample throughput; a simple and rapid analytical procedure is a prerequisite. In order to speed-up the existing methodology, phosphate fusion was introduced for decomposition of samples. In the proposed method, bromoform-heavies material are fused with 1:1 mixture of sodium dihydrogen orthophosphate and tetra-sodium pyrophosphate and dissolved in distilled water. After disintegration of melt, the solution was subjected to oxalate precipitation followed by R 2 O 3 separation for separating the REEs from major matrix interfering elements. The rare earth elements and thorium in the resultant solution were determined by ICP-OES. The results are compared with the results obtained by well-established existing dissolution procedures involving HF-HCl-HClO 4 acid treatment and NaF/KHF 2 fusion followed by H 2 SO 4 acid fuming. The accuracy of the method was evaluated by doping the phosphate blank with known amount of REEs and comparing the recoveries obtained using the present method. The method is simple, rapid and is suitable for the routine determination of REEs and Th in bromoform-heavies. The RSD of the method was found to be within 1-3% for Th and REEs by ICP-AES. (author)

  14. Fast and simple fat grafting of the breast

    DEFF Research Database (Denmark)

    Kristensen, Rasmus Nygård; Gunnarsson, Gudjon L; Børsen-Koch, Mikkel

    2015-01-01

    Fat grafting (FG) is being used at an escalating rate for correction of shape and volume of all types of breast surgery in order to optimize the aesthetic result in spite of an ongoing debate of the oncologic safety. In this paper we demonstrate our simple and fast sedimentation based FG technique...... in the attached video as visualized surgery. We have used this simple approach for 348 procedures in 176 women to optimize and correct the aesthetic result following all types of breast surgery. We prefer this simple technique as no technique has been shown to be superior to other more costly techniques...... and furthermore there are still questions about the oncologic safety in using adipose derived stem cells (ADSC). Simple fat harvesting using low vacuum and preparation by sedimentation is a fast and effective method to perform FG successfully for correction of shape and volume deficits of the breast following...

  15. A simple and selective colorimetric mercury (II) sensing system based on chitosan stabilized gold nanoparticles and 2,6-pyridinedicarboxylic acid

    Energy Technology Data Exchange (ETDEWEB)

    Tian, Kun; Siegel, Gene; Tiwari, Ashutosh, E-mail: tiwari@eng.utah.edu

    2017-02-01

    The development of simple and cost-effective methods for the detection and treatment of Hg{sup 2+} in the environment is an important area of research due to the serious health risk that Hg{sup 2+} poses to humans. Colorimetric sensing based on the induced aggregation of nanoparticles is of great interest since it offers a low cost, simple, and relatively rapid procedure, making it perfect for on-site analysis. Herein we report the development of a simple colorimetric sensor for the selective detection and estimation of mercury ions in water, based on chitosan stabilized gold nanoparticles (AuNPs) and 2,6-pyridinedicarboxylic acid (PDA). In the presence of Hg{sup 2+}, PDA induces the aggregation of AuNPs, causing the solution to change colors varying from red to blue, depending on the concentration of Hg{sup 2+}. The formation of aggregated AuNPs in the presence of Hg{sup 2+} was confirmed using transmission electron microscopy (TEM) and UV–Vis spectroscopy. The method exhibits linearity in the range of 300 nM to 5 μM and shows excellent selectivity towards Hg{sup 2+} among seventeen different metal ions and was successfully applied for the detection of Hg{sup 2+} in spiked river water samples. The developed technique is simple and superior to the existing techniques in that it allows detection of Hg{sup 2+} using the naked eye and simple and rapid colorimetric analysis, which eliminates the need for sophisticated instruments and sample preparation methods. - Highlights: • A simple colorimetric method for detection of Hg{sup 2+} in water was proposed. • Au nanoparticles and 2,6-pyridinedicarboxylic acid were used for sensing Hg{sup 2+}. • Sensing mechanisms were demonstrated by TEM and UV–Visible measurements. • It showed the solution color changes from red to blue upon addition of Hg{sup 2+}. • The method selectively detected Hg{sup 2+} among seventeen different metal ions.

  16. An automated background estimation procedure for gamma ray spectra

    International Nuclear Information System (INIS)

    Tervo, R.J.; Kennett, T.J.; Prestwich, W.V.

    1983-01-01

    An objective and simple method has been developed to estimate the background continuum in Ge gamma ray spectra. Requiring no special procedures, the method is readily automated. Based upon the inherent statistical properties of the experimental data itself, nodes, which reflect background samples are located and used to produce an estimate of the continuum. A simple procedure to interpolate between nodes is reported and a range of rather typical experimental data is presented. All information necessary to implemented this technique is given including the relevant properties of various factors involved in its development. (orig.)

  17. Measurement of Actinides in Molybdenum-99 Solution Analytical Procedure

    International Nuclear Information System (INIS)

    Soderquist, Chuck Z.; Weaver, Jamie L.

    2015-01-01

    This document is a companion report to a previous report, PNNL 24519, Measurement of Actinides in Molybdenum-99 Solution, A Brief Review of the Literature, August 2015. In this companion report, we report a fast, accurate, newly developed analytical method for measurement of trace alpha-emitting actinide elements in commercial high-activity molybdenum-99 solution. Molybdenum-99 is widely used to produce 99m Tc for medical imaging. Because it is used as a radiopharmaceutical, its purity must be proven to be extremely high, particularly for the alpha emitting actinides. The sample of 99 Mo solution is measured into a vessel (such as a polyethylene centrifuge tube) and acidified with dilute nitric acid. A gadolinium carrier is added (50 µg). Tracers and spikes are added as necessary. Then the solution is made strongly basic with ammonium hydroxide, which causes the gadolinium carrier to precipitate as hydrous Gd(OH) 3 . The precipitate of Gd(OH) 3 carries all of the actinide elements. The suspension of gadolinium hydroxide is then passed through a membrane filter to make a counting mount suitable for direct alpha spectrometry. The high-activity 99 Mo and 99m Tc pass through the membrane filter and are separated from the alpha emitters. The gadolinium hydroxide, carrying any trace actinide elements that might be present in the sample, forms a thin, uniform cake on the surface of the membrane filter. The filter cake is first washed with dilute ammonium hydroxide to push the last traces of molybdate through, then with water. The filter is then mounted on a stainless steel counting disk. Finally, the alpha emitting actinide elements are measured by alpha spectrometry.

  18. CONCORDAT PROCEDURE. LEGISLATIVE AND JURISPRUDENTIAL HIGHLIGHTS

    Directory of Open Access Journals (Sweden)

    Mihaela Tofan

    2014-11-01

    Full Text Available Insolvency Code has revived theoreticians’ and practitioners’ discussions, equally. The voluntary arrangements procedure is considered a legal solution for the prevention and recovery from commercial actors’ financial difficulty. The current legal framework establishes a number of imperative conditions for the implementation of this procedure, but in many cases, the application of the current regulation generated different conclusions. In less than half a year, since the entry into force of the law, the practice for each court varied. The paper synthesizes separate opinions and proposes solutions for shaping a more precise legal framework.

  19. Irradiation creep in simple binary alloys

    International Nuclear Information System (INIS)

    Nagakawa, J.; Sethi, V.K.; Turner, A.P.L.

    1981-07-01

    Creep enhancement during 21-MeV deuteron irradiation was examined at 350 0 C for two simple binary alloys with representative microstructures, i.e., solid-solution (Ni - 4 at. % Si) and precipitation-hardened (Ni - 12.8 at. % Al) alloys. Coherent precipitates were found to be very effective in suppressing irradiation-enhanced creep. Si solute atoms depressed irradiation creep moderately and caused irradiation hardening via radiation-induced segregation. The stress-dependence of irradiation creep in Ni - 4 at. % Si should a transition, which seems to reflect a change of mechanism from dislocation climb due to stress-induced preferential absorption (SIPA) to climb-controlled dislocation glide enhanced by irradiation

  20. A simple mixture to enhance muscle transmittance

    Science.gov (United States)

    Oliveira, Luís; Lage, Armindo; Clemente, Manuel Pais; Tuchin, Valery V.

    2008-06-01

    Skeletal muscle is a fibrous tissue composed by muscle fibers and interstitial fluid. Due to this constitution, the muscle presents a non uniform refractive index profile that origins strong light scattering. One way to improve tissue transmittance is to reduce this refractive index mismatch by immersing the muscle in an optical clearing agent. As a consequence of such immersion tissue also suffers dehydration. The study of the optical clearing effect created by a simple mixture composed by ethanol, glycerol and distilled water has proven its effectiveness according to the variations observed in the parameters under study. The effect was characterized in terms of its magnitude, time duration and histological variations. The applied treatment has created a small reduction of the global sample refractive index that is justified by the long time rehydration caused by water in the immersing solution. From the reduction in sample pH we could also identify the dehydration process created in the sample. The immersion treatment has originated fiber bundle contraction and a spread distribution of the muscle fiber bundles inside. New studies with the mixture used, or with other combinations of its constituents might be interesting to perform with the objective to develop new clinical procedures.

  1. Simple systems abroad coupled to hight-tech solutions : MexiCultura: cooperation between Holland and Mexico

    NARCIS (Netherlands)

    Velden, van P.; Elings, A.

    2015-01-01

    Doing business with Mexican entrepreneurs is high on the wish list of Dutch companies. That’s not so simple when you’re used to building high-tech greenhouses. Yet the local growers want to improve their current methods of production. The Dutch can be of service by offering knowledge about simple

  2. 7 CFR 1221.108 - Procedure.

    Science.gov (United States)

    2010-01-01

    ... Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (MARKETING AGREEMENTS... INFORMATION ORDER Sorghum Promotion, Research, and Information Order Sorghum Promotion, Research, and Information Board § 1221.108 Procedure. (a) At a Board meeting, it will be considered a quorum when a simple...

  3. Simple and double microencapsulation of Lactobacillus acidophilus with chitosan using spray drying

    Directory of Open Access Journals (Sweden)

    Isela A. Flores-Belmont

    2015-10-01

    Full Text Available The aim of this study was to evaluate the survival of Lactobacillus acidophilus that had been simple or double spray dried using chitosan to cause microencapsulation and which had been exposed to model gastrointestinal conditions. In addition, the study also determined the physicochemical properties of the powder containing the microencapsulated probiotic.Chitosan-inulin or chitosan-maltodextrin (1:15 or 1:25 solutions were inoculated with 1012 cfu mL-1 of L. acidophilus, for simple microencapsulation. The different solutions were dried using a spray dryer with an inlet air temperature of 130°C and a solution flux of 4.8 g min-1. A two-step process was used for the double microencapsulation. In the first step, the probiotic was added to a gelatin-maltodextrin (1:25 solution and then spray dried; for the second step, the microencapsulated probiotic was added to a chitosan-inulin or chitosan-maltodextrin (1:25 solution and then it was spray dried again.With the simple microencapsulated probiotic, a microbial reduction of 7 log cycles was obtained. With the double microencapsulated probiotic only 3 log reductions were achieved. The double microencapsulated probiotic thus demonstrated greater resistance to simulated gastrointestinal conditions. The powders produced were shown to have water activity values of 0.176 - 0.261 at 25 °C and moisture content of 0.8 – 1.0%, which are characteristic of spray dried products. The bulk density was significantly (p < 0.05 lower (300 kg m-3 for simple than for double (400 kg m-3 microencapsulated probiotic powders. Solubility and dispersibility of the powder microcapsules were better at lower pH values.Double microencapsulation using a process of spray drying is therefore recommended for probiotics, thus exploiting chitosan’s insolubility in water, which can be applied for the of development food products.

  4. Development of a Cognitive Robotic System for Simple Surgical Tasks

    Directory of Open Access Journals (Sweden)

    Riccardo Muradore

    2015-04-01

    Full Text Available The introduction of robotic surgery within the operating rooms has significantly improved the quality of many surgical procedures. Recently, the research on medical robotic systems focused on increasing the level of autonomy in order to give them the possibility to carry out simple surgical actions autonomously. This paper reports on the development of technologies for introducing automation within the surgical workflow. The results have been obtained during the ongoing FP7 European funded project Intelligent Surgical Robotics (I-SUR. The main goal of the project is to demonstrate that autonomous robotic surgical systems can carry out simple surgical tasks effectively and without major intervention by surgeons. To fulfil this goal, we have developed innovative solutions (both in terms of technologies and algorithms for the following aspects: fabrication of soft organ models starting from CT images, surgical planning and execution of movement of robot arms in contact with a deformable environment, designing a surgical interface minimizing the cognitive load of the surgeon supervising the actions, intra-operative sensing and reasoning to detect normal transitions and unexpected events. All these technologies have been integrated using a component-based software architecture to control a novel robot designed to perform the surgical actions under study. In this work we provide an overview of our system and report on preliminary results of the automatic execution of needle insertion for the cryoablation of kidney tumours.

  5. Measurement of Actinides in Molybdenum-99 Solution Analytical Procedure

    Energy Technology Data Exchange (ETDEWEB)

    Soderquist, Chuck Z. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Weaver, Jamie L. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2015-11-01

    This document is a companion report to a previous report, PNNL 24519, Measurement of Actinides in Molybdenum-99 Solution, A Brief Review of the Literature, August 2015. In this companion report, we report a fast, accurate, newly developed analytical method for measurement of trace alpha-emitting actinide elements in commercial high-activity molybdenum-99 solution. Molybdenum-99 is widely used to produce 99mTc for medical imaging. Because it is used as a radiopharmaceutical, its purity must be proven to be extremely high, particularly for the alpha emitting actinides. The sample of 99Mo solution is measured into a vessel (such as a polyethylene centrifuge tube) and acidified with dilute nitric acid. A gadolinium carrier is added (50 µg). Tracers and spikes are added as necessary. Then the solution is made strongly basic with ammonium hydroxide, which causes the gadolinium carrier to precipitate as hydrous Gd(OH)3. The precipitate of Gd(OH)3 carries all of the actinide elements. The suspension of gadolinium hydroxide is then passed through a membrane filter to make a counting mount suitable for direct alpha spectrometry. The high-activity 99Mo and 99mTc pass through the membrane filter and are separated from the alpha emitters. The gadolinium hydroxide, carrying any trace actinide elements that might be present in the sample, forms a thin, uniform cake on the surface of the membrane filter. The filter cake is first washed with dilute ammonium hydroxide to push the last traces of molybdate through, then with water. The filter is then mounted on a stainless steel counting disk. Finally, the alpha emitting actinide elements are measured by alpha spectrometry.

  6. Chemical Kinetics, Heat Transfer, and Sensor Dynamics Revisited in a Simple Experiment

    Science.gov (United States)

    Sad, Maria E.; Sad, Mario R.; Castro, Alberto A.; Garetto, Teresita F.

    2008-01-01

    A simple experiment about thermal effects in chemical reactors is described, which can be used to illustrate chemical reactor models, the determination and validation of their parameters, and some simple principles of heat transfer and sensor dynamics. It is based in the exothermic reaction between aqueous solutions of sodium thiosulfate and…

  7. Treatment for hydrazine-containing waste water solution

    Science.gov (United States)

    Yade, N.

    1986-01-01

    The treatment for waste solutions containing hydrazine is presented. The invention attempts oxidation and decomposition of hydrazine in waste water in a simple and effective processing. The method adds activated charcoal to waste solutions containing hydrazine while maintaining a pH value higher than 8, and adding iron salts if necessary. Then, the solution is aerated.

  8. Single-session percutaneous ethanol sclerotherapy in simple renal cysts in children: long-term follow-up

    Energy Technology Data Exchange (ETDEWEB)

    Akinci, Devrim; Gumus, Burcak; Ozkan, Orhan S.; Ozmen, Mustafa N.; Akhan, Okan [Hacettepe University School of Medicine, Department of Radiology, Ankara (Turkey)

    2005-02-01

    Simple renal cysts are rare in children and managed conservatively unless symptomatic. To demonstrate the efficacy and long-term results of single-session ethanol sclerotherapy in symptomatic simple renal cysts in children. Three simple renal cysts in three children (age 1, 5 and 16 years) were included in the study. Indications for treatment were flank pain (n=1), hypertension (n=1), and increasing cyst size and urinary tract infection (n=1). The mean follow-up period was 5.5 years (range 3-7 years). The procedures were performed with the guidance of US and fluoroscopy and under IV sedation. After the cystogram, 95% ethanol with a volume of 40% of the cyst volume (but not more than 100 ml) was used as the sclerosing agent. Two cysts disappeared completely, while the volume reduction was 99% for the third cyst at the end of the first year. CT demonstrated calcification of the cyst without an enhancing soft-tissue component in the third one 7 years after sclerotherapy. After the procedures, hypertension and pain resolved without any medication. There were no complications during the procedures or during follow-up. Cytological examination was unremarkable in all patients. Percutaneous treatment of symptomatic simple renal cysts in children with single-session ethanol sclerotherapy is a safe, effective and minimally invasive procedure. Calcification owing to sclerotherapy can be observed on follow-up. (orig.)

  9. Evaluation of sedation for standing clinical procedures in horses using detomidine combined with buprenorphine.

    Science.gov (United States)

    Taylor, Polly; Coumbe, Karen; Henson, Frances; Scott, David; Taylor, Alan

    2014-01-01

    To examine the effect of including buprenorphine with detomidine for sedation of horses undergoing clinical procedures. Partially blinded, randomised, prospective clinical field trial. Eighty four client-owned horses scheduled for minor surgery or diagnostic investigation under standing sedation. The effects of buprenorphine (5 μg kg(-1) ) (Group B, n = 46) or placebo (5% glucose solution) (Group C, n = 38) in combination with detomidine (10 μg kg(-1) ) were compared in standing horses undergoing minor clinical procedures. The primary outcome measure was successful completion of the procedure. The degree of sedation and ataxia were scored using simple descriptive scales. Heart and respiratory rates were recorded at 15-30 minute intervals. Parametric data from each group were compared using anova or t-test and non parametric data using the Mann-Whitney U test. The procedure was carried out successfully in 91% of Group B and 63% of Group C (p detomidine, increased after buprenorphine but not glucose administration, was more profound in group B and lasted longer (60 versus 30 minutes) p detomidine 10 and 20 μg kg(-1) with minor side effects similar to other alpha2 agonist/opioid combinations. Detomidine-buprenorphine sedation is suitable for standing procedures in horses. © 2013 Association of Veterinary Anaesthetists and the American College of Veterinary Anesthesia and Analgesia.

  10. Efficient Reanalysis Procedures in Structural Topology Optimization

    DEFF Research Database (Denmark)

    Amir, Oded

    This thesis examines efficient solution procedures for the structural analysis problem within topology optimization. The research is motivated by the observation that when the nested approach to structural optimization is applied, most of the computational effort is invested in repeated solutions...... on approximate reanalysis. For cases where memory limitations require the utilization of iterative equation solvers, we suggest efficient procedures based on alternative termination criteria for such solvers. These approaches are tested on two- and three-dimensional topology optimization problems including...

  11. A modified-simple technique of removing the lens cortex during cataract surgery

    Directory of Open Access Journals (Sweden)

    Kyung Eun Han

    2017-01-01

    Full Text Available We describe here a surgical technique of removing the remaining cortex after phacoemulsification without performing the conventional irrigation/aspiration (I/A procedure. In this technique, the remaining cortex attached to the posterior capsule was separated and dissected into several pieces by continuous irrigation with balanced salt solution, which was supplied through a syringe attached to a bent, blunt-tip needle. Approximately, 10 s of manual irrigation separated most of the remaining cortex from the posterior capsule. Then, the capsular bag was inflated with an ophthalmic viscoelastic device (OVD, and this pushed the separated cortex toward the capsular fornix mechanically. An intraocular lens was inserted into the capsular bag, following which the remaining cortex and OVD were removed concomitantly using an automated I/A handpiece. This technique is a simple and easy maneuver to remove the cortex from all areas, including the subincisional area, and reduce the possibility of a posterior capsule tear.

  12. Transthoracic Adrenal Biopsy Procedure Using Artificial Carbon Dioxide Pneumothorax as Outpatient Procedure

    Energy Technology Data Exchange (ETDEWEB)

    Favelier, Sylvain [CHU (University Hospital), Department of Radiology (France); Guiu, Severine [Georges-Francois Leclerc Cancer Center, Department of Oncology (France); Cherblanc, Violaine; Cercueil, Jean-Pierre; Krause, Denis; Guiu, Boris, E-mail: boris.guiu@chu-dijon.fr [CHU (University Hospital), Department of Radiology (France)

    2013-08-01

    Many routes have been described for percutaneous adrenal gland biopsy. They require either a complex non-axial path or a long hydrodissection or even pass through an organ thereby increasing complications. We describe here an approach using an artificially-induced carbon dioxide (CO{sub 2}) pneumothorax, performed as an outpatient procedure in a 57-year-old woman. Under local anaesthesia, 200 ml of CO{sub 2} was injected in the pleural space through a Veress needle under computed tomography fluoroscopy, to clear the lung parenchyma from the biopsy route. Using this technique, transthoracic adrenal biopsy can be performed under simple local anaesthesia as an safely outpatient procedure.

  13. A simple square-wave voltammetric method for the determination of scopolamine in pharmaceuticals using a boron-doped diamond electrode

    Directory of Open Access Journals (Sweden)

    Simone Birkheur Santos

    2014-01-01

    Full Text Available A simple procedure is described for the determination of scopolamine by square-wave voltammetry using a cathodically pretreated boron-doped diamond electrode. Cyclic voltammetry studies indicate that the oxidation of scopolamine is irreversible at a peak potential of 1.59 V (vs. Ag/AgCl (3.0 mol L-1 KCl in a 0.50 mol L-1 sulfuric acid solution. Under optimized conditions, the analytical curve obtained was linear (r = 0.9996 for the scopolamine concentration range of 1.0 to 110 µmol L-1, with a detection limit of 0.84 µmol L-1. The method was successfully applied to the determination of scopolamine in pharmaceutical formulations with minimum sample preparation.

  14. A simple method for validation and verification of pipettes mounted on automated liquid handlers

    DEFF Research Database (Denmark)

    Stangegaard, Michael; Hansen, Anders Johannes; Frøslev, Tobias Guldberg

     We have implemented a simple method for validation and verification of the performance of pipettes mounted on automated liquid handlers as necessary for laboratories accredited under ISO 17025. An 8-step serial dilution of Orange G was prepared in quadruplicates in a flat bottom 96-well microtit...... available. In conclusion, we have set up a simple solution for the continuous validation of automated liquid handlers used for accredited work. The method is cheap, simple and easy to use for aqueous solutions but requires a spectrophotometer that can read microtiter plates....... We have implemented a simple method for validation and verification of the performance of pipettes mounted on automated liquid handlers as necessary for laboratories accredited under ISO 17025. An 8-step serial dilution of Orange G was prepared in quadruplicates in a flat bottom 96-well microtiter...

  15. Chemical, mass spectrometric, spectrochemical, nuclear, and radiochemical analysis of nuclear-grade plutonium nitrate solutions

    International Nuclear Information System (INIS)

    Anon.

    1981-01-01

    These analytical procedures are designed to show whether a given material meets the purchaser's specifications as to plutonium content, effective fissile content, and impurity content. The following procedures are described in detail: plutonium by controlled-potential coulometry; plutonium by amperometric titration with iron(II); free acid by titration in an oxalate solution; free acid by iodate precipitation-potentiometric titration method; uranium by Arsenazo I spectrophotometric method; thorium by thorin spectrophotometric method; iron by 1,10-phenanthroline spectrophotometric method; chloride by thiocyanate spectrophotometric method; fluoride by distillation-spectrophotometric method; sulfate by barium sulfate turbidimetric method; isotopic composition by mass spectrometry; americium-241 by extraction and gamma counting; americium-241 by gamma counting; gamma-emitting fission products, uranium, and thorium by gamma-ray spectroscopy; rare earths by copper spark spectrochemical method; tungsten, niobium (columbium), and tantalum by spectrochemical method; simple preparation by spectrographic analysis for general impurities

  16. Wrist arthrography: a simple method

    Energy Technology Data Exchange (ETDEWEB)

    Berna-Serna, Juan D.; Reus, Manuel; Alonso, Jose [Virgen de la Arrixaca University Hospital, Department of Radiology, El Palmar (Murcia) (Spain); Martinez, Francisco; Domenech-Ratto, Gines [University of Murcia, Department of Human Anatomy, Faculty of Medicine, Murcia (Spain)

    2006-02-01

    A technique of wrist arthrography is presented using an adhesive marker-plate with radiopaque coordinates to identify precisely sites for puncture arthrography of the wrist and to obviate the need for fluoroscopic guidance. Radiocarpal joint arthrography was performed successfully in all 24 cases, 14 in the cadaveric wrists and 10 in the live patients. The arthrographic procedure described in this study is simple, safe, and rapid, and has the advantage of precise localisation of the site for puncture without need for fluoroscopic guidance. (orig.)

  17. Special Relativity as a Simple Geometry Problem

    Science.gov (United States)

    de Abreu, Rodrigo; Guerra, Vasco

    2009-01-01

    The null result of the Michelson-Morley experiment and the constancy of the one-way speed of light in the "rest system" are used to formulate a simple problem, to be solved by elementary geometry techniques using a pair of compasses and non-graduated rulers. The solution consists of a drawing allowing a direct visualization of all the fundamental…

  18. On timelike supersymmetric solutions of gauged minimal 5-dimensional supergravity

    Energy Technology Data Exchange (ETDEWEB)

    Chimento, Samuele; Ortín, Tomás [Instituto de Física Teórica UAM/CSIC,C/Nicolás Cabrera, 13-15, C.University Cantoblanco, E-28049 Madrid (Spain)

    2017-04-04

    We analyze the timelike supersymmetric solutions of minimal gauged 5-dimensional supergravity for the case in which the Kähler base manifold admits a holomorphic isometry and depends on two real functions satisfying a simple second-order differential equation. Using this general form of the base space, the equations satisfied by the building blocks of the solutions become of, at most, fourth degree and can be solved by simple polynomic ansatzs. In this way we construct two 3-parameter families of solutions that contain almost all the timelike supersymmetric solutions of this theory with one angular momentum known so far and a few more: the (singular) supersymmetric Reissner-Nordström-AdS solutions, the three exact supersymmetric solutions describing the three near-horizon geometries found by Gutowski and Reall, three 1-parameter asymptotically-AdS{sub 5} black-hole solutions with those three near-horizon geometries (Gutowski and Reall’s black hole being one of them), three generalizations of the Gödel universe and a few potentially homogenous solutions. A key rôle in finding these solutions is played by our ability to write AdS{sub 5}’s Kähler base space ( (ℂℙ)-bar {sup 2} or SU(1,2)/U(2)) is three different, yet simple, forms associated to three different isometries. Furthermore, our ansatz for the Kähler metric also allows us to study the dimensional compactification of the theory and its solutions in a systematic way.

  19. 49 CFR 1141.1 - Procedures to calculate interest rates.

    Science.gov (United States)

    2010-10-01

    ... the portion of the year covered by the interest rate. A simple multiplication of the nominal rate by... 49 Transportation 8 2010-10-01 2010-10-01 false Procedures to calculate interest rates. 1141.1... TRANSPORTATION BOARD, DEPARTMENT OF TRANSPORTATION RULES OF PRACTICE PROCEDURES TO CALCULATE INTEREST RATES...

  20. A Simple Quantitative Synthesis: Sodium Chloride from Sodium Carbonate.

    Science.gov (United States)

    Gold, Marvin

    1988-01-01

    Describes a simple laboratory procedure for changing sodium carbonate into sodium chloride by adding concentrated HCl to cause the reaction and then evaporating the water. Claims a good stoichiometric yield can be obtained in one three-hour lab period. Suggests using fume hood for the reaction. (ML)

  1. Procedural sedation analgesia

    Directory of Open Access Journals (Sweden)

    Sheta Saad

    2010-01-01

    Full Text Available The number of noninvasive and minimally invasive procedures performed outside of the operating room has grown exponentially over the last several decades. Sedation, analgesia, or both may be needed for many of these interventional or diagnostic procedures. Individualized care is important when determining if a patient requires procedural sedation analgesia (PSA. The patient might need an anti-anxiety drug, pain medicine, immobilization, simple reassurance, or a combination of these interventions. The goals of PSA in four different multidisciplinary practices namely; emergency, dentistry, radiology and gastrointestinal endoscopy are discussed in this review article. Some procedures are painful, others painless. Therefore, goals of PSA vary widely. Sedation management can range from minimal sedation, to the extent of minimal anesthesia. Procedural sedation in emergency department (ED usually requires combinations of multiple agents to reach desired effects of analgesia plus anxiolysis. However, in dental practice, moderate sedation analgesia (known to the dentists as conscious sedation is usually what is required. It is usually most effective with the combined use of local anesthesia. The mainstay of success for painless imaging is absolute immobility. Immobility can be achieved by deep sedation or minimal anesthesia. On the other hand, moderate sedation, deep sedation, minimal anesthesia and conventional general anesthesia can be all utilized for management of gastrointestinal endoscopy.

  2. Simple waves in a two-component Bose-Einstein condensate

    Science.gov (United States)

    Ivanov, S. K.; Kamchatnov, A. M.

    2018-04-01

    We study the dynamics of so-called simple waves in a two-component Bose-Einstein condensate. The evolution of the condensate is described by Gross-Pitaevskii equations which can be reduced for these simple wave solutions to a system of ordinary differential equations which coincide with those derived by Ovsyannikov for the two-layer fluid dynamics. We solve the Ovsyannikov system for two typical situations of large and small difference between interspecies and intraspecies nonlinear interaction constants. Our analytic results are confirmed by numerical simulations.

  3. Analytical solutions for one-dimensional advection–dispersion ...

    Indian Academy of Sciences (India)

    We present simple analytical solutions for the unsteady advection–dispersion equations describing the pollutant concentration (, ) in one dimension. The solutions are obtained by using Laplace transformation technique. In this study we divided the river into two regions ≤ 0 and ≥0 and the origin at = 0.

  4. Application of a space-time CE/SE (Conversation Element/Solution Element) method to the numerical solution of chromatographic separation processes

    DEFF Research Database (Denmark)

    including convection-difmsion-reaction PDEs are numerically solved using the two methods on the same spatial grid. Even though the CE/SE method uses a simple stencil structure and is developed on a simple mathematical basis (i.e., Gauss' divergence theorem), accurate and computationally-efficient solutions...

  5. A simple application of the Newman-Penrose spin coefficient formalism

    International Nuclear Information System (INIS)

    Davis, T.M.

    1976-01-01

    As a simple application of the Newman-Penrose spin coefficient formalism, useful for beginners, the vacuum symmetry (Schwarzschild) solution is found. The calculations also show that all spherically symmetric metrics are Petrov type D. (author)

  6. A class of Yang-Mills solutions

    International Nuclear Information System (INIS)

    Castillejo, L.; Kugler, M.

    1980-09-01

    We investigate a class of solutions of the classical SU(2) Yang-Mills equations. The symmetry of this class prescribes a natural set of gauge invariant degrees of freedom. Using these degrees of freedom we obtain a simple set of equations which enables us to find all the solutions belonging to the class under discussion. (Author)

  7. A Comparison of Simple Methods to Incorporate Material Temperature Dependency in the Green’s Function Method for Estimating Transient Thermal Stresses in Thick-Walled Power Plant Components

    Directory of Open Access Journals (Sweden)

    James Rouse

    2016-01-01

    Full Text Available The threat of thermal fatigue is an increasing concern for thermal power plant operators due to the increasing tendency to adopt “two-shifting” operating procedures. Thermal plants are likely to remain part of the energy portfolio for the foreseeable future and are under societal pressures to generate in a highly flexible and efficient manner. The Green’s function method offers a flexible approach to determine reference elastic solutions for transient thermal stress problems. In order to simplify integration, it is often assumed that Green’s functions (derived from finite element unit temperature step solutions are temperature independent (this is not the case due to the temperature dependency of material parameters. The present work offers a simple method to approximate a material’s temperature dependency using multiple reference unit solutions and an interpolation procedure. Thermal stress histories are predicted and compared for realistic temperature cycles using distinct techniques. The proposed interpolation method generally performs as well as (if not better than the optimum single Green’s function or the previously-suggested weighting function technique (particularly for large temperature increments. Coefficients of determination are typically above 0 . 96 , and peak stress differences between true and predicted datasets are always less than 10 MPa.

  8. A simple two stage optimization algorithm for constrained power economic dispatch

    International Nuclear Information System (INIS)

    Huang, G.; Song, K.

    1994-01-01

    A simple two stage optimization algorithm is proposed and investigated for fast computation of constrained power economic dispatch control problems. The method is a simple demonstration of the hierarchical aggregation-disaggregation (HAD) concept. The algorithm first solves an aggregated problem to obtain an initial solution. This aggregated problem turns out to be classical economic dispatch formulation, and it can be solved in 1% of overall computation time. In the second stage, linear programming method finds optimal solution which satisfies power balance constraints, generation and transmission inequality constraints and security constraints. Implementation of the algorithm for IEEE systems and EPRI Scenario systems shows that the two stage method obtains average speedup ratio 10.64 as compared to classical LP-based method

  9. New exact solutions of the mBBM equation

    International Nuclear Information System (INIS)

    Zhang Zhe; Li Desheng

    2013-01-01

    The enhanced modified simple equation method presented in this article is applied to construct the exact solutions of modified Benjamin-Bona-Mahoney equation. Some new exact solutions are derived by using this method. When some parameters are taken as special values, the solitary wave solutions can be got from the exact solutions. It is shown that the method introduced in this paper has general significance in searching for exact solutions to the nonlinear evolution equations. (authors)

  10. The Double-Well Potential in Quantum Mechanics: A Simple, Numerically Exact Formulation

    Science.gov (United States)

    Jelic, V.; Marsiglio, F.

    2012-01-01

    The double-well potential is arguably one of the most important potentials in quantum mechanics, because the solution contains the notion of a state as a linear superposition of "classical" states, a concept which has become very important in quantum information theory. It is therefore desirable to have solutions to simple double-well potentials…

  11. Double-resolution electron holography with simple Fourier transform of fringe-shifted holograms

    International Nuclear Information System (INIS)

    Volkov, V.V.; Han, M.G.; Zhu, Y.

    2013-01-01

    We propose a fringe-shifting holographic method with an appropriate image wave recovery algorithm leading to exact solution of holographic equations. With this new method the complex object image wave recovered from holograms appears to have much less traditional artifacts caused by the autocorrelation band present practically in all Fourier transformed holograms. The new analytical solutions make possible a double-resolution electron holography free from autocorrelation band artifacts and thus push the limits for phase resolution. The new image wave recovery algorithm uses a popular Fourier solution of the side band-pass filter technique, while the fringe-shifting holographic method is simple to implement in practice. - Highlights: • We propose a fringe-shifting holographic method simple enough for practical implementations. • Our new image-wave-recovery algorithm follows from exact solution of holographic equations. • With autocorrelation band removal from holograms it is possible to achieve double-resolution electron holography data free from several commonly known artifacts. • The new fringe-shifting method can reach an image wave resolution close to single fringe spacing

  12. Double-resolution electron holography with simple Fourier transform of fringe-shifted holograms

    Energy Technology Data Exchange (ETDEWEB)

    Volkov, V.V., E-mail: volkov@bnl.gov; Han, M.G.; Zhu, Y.

    2013-11-15

    We propose a fringe-shifting holographic method with an appropriate image wave recovery algorithm leading to exact solution of holographic equations. With this new method the complex object image wave recovered from holograms appears to have much less traditional artifacts caused by the autocorrelation band present practically in all Fourier transformed holograms. The new analytical solutions make possible a double-resolution electron holography free from autocorrelation band artifacts and thus push the limits for phase resolution. The new image wave recovery algorithm uses a popular Fourier solution of the side band-pass filter technique, while the fringe-shifting holographic method is simple to implement in practice. - Highlights: • We propose a fringe-shifting holographic method simple enough for practical implementations. • Our new image-wave-recovery algorithm follows from exact solution of holographic equations. • With autocorrelation band removal from holograms it is possible to achieve double-resolution electron holography data free from several commonly known artifacts. • The new fringe-shifting method can reach an image wave resolution close to single fringe spacing.

  13. Simple and inexpensive microfluidic devices for the generation of monodisperse multiple emulsions

    KAUST Repository

    Li, Erqiang

    2013-12-16

    Droplet-based microfluidic devices have become a preferred versatile platform for various fields in physics, chemistry and biology. Polydimethylsiloxane soft lithography, the mainstay for fabricating microfluidic devices, usually requires the usage of expensive apparatus and a complex manufacturing procedure. Here, we report the design and fabrication of simple and inexpensive microfluidic devices based on microscope glass slides and pulled glass capillaries, for generating monodisperse multiple emulsions. The advantages of our method lie in a simple manufacturing procedure, inexpensive processing equipment and flexibility in the surface modification of the designed microfluidic devices. Different types of devices have been designed and tested and the experimental results demonstrated their robustness for preparing monodisperse single, double, triple and multi-component emulsions. © 2014 IOP Publishing Ltd.

  14. A procedure for effective Dancoff factor calculation

    International Nuclear Information System (INIS)

    Milosevic, M.

    2001-01-01

    In this paper, a procedure for Dancoff factors calculation based on equivalence principle and its application in the SCALE-4.3 code system is described. This procedure is founded on principle of conservation of neutron absorption for resolved resonance range in a heterogeneous medium and an equivalent medium consisted of an infinite array of two-region pin cells, where the presence of other fuel rods is taken into account through a Dancoff factor. The neutron absorption in both media is obtained using a fine-group elastic slowing-down calculation. This procedure is implemented in a design oriented lattice physics code, which is applicable for any geometry where the method of collision probability is possible to apply to get a flux solution. Proposed procedure was benchmarked for recent exercise that represents a system with a fuel double heterogeneity, i.e., fuel in solid form (pellets) surrounded by fissile material in solution, and for a 5x5 irregular pressurised water reactor assembly, which requires different Dancoff factors. (author)

  15. Americium separations from high salt solutions

    International Nuclear Information System (INIS)

    Barr, Mary E.; Jarvinen, Gordon D.; Schulte, Louis D.; Stark, Peter C.; Chamberlin, Rebecca M.; Abney, Kent D.; Ricketts, Thomas E.; Valdez, Yvette E.; Bartsch, Richard A.

    2000-01-01

    Americium (III) exhibits an unexpectedly high affinity for anion-exchange material from the high-salt evaporator bottoms solutions--an effect which has not been duplicated using simple salt solutions. Similar behavior is observed for its lanthanide homologue, Nd(III), in complex evaporator bottoms surrogate solutions. There appears to be no single controlling factor--acid concentration, total nitrate concentration or solution ionic strength--which accounts for the approximately 2-fold increase in retention of the trivalent ions from complex solutions relative to simple solutions. Calculation of species activities (i.e., water, proton and nitrate) in such concentrated mixed salt solutions is difficult and of questionable accuracy, but it is likely that the answer to forcing formation of anionic nitrate complexes of americium lies in the relative activities of water and nitrate. From a practical viewpoint, the modest americium removal needs (ca. 50--75%) from nitric acid evaporator bottoms allow sufficient latitude for the use of non-optimized conditions such as running existing columns filled with older, well-used Reillex HPQ. Newer materials, such as HPQ-100 and the experimental bifunctional resins, which exhibit higher distribution coefficients, would allow for either increased Am removal or the use of smaller columns. It is also of interest that one of the experimental neutral-donor solid-support extractants, DHDECMP, exhibits a similarly high level of americium (total alpha) removal from EV bottoms and is much less sensitive to total acid content than commercially-available material

  16. Procedure to use phosphogypsum industrial waste for mineral CO2 sequestration

    International Nuclear Information System (INIS)

    Cárdenas-Escudero, C.; Morales-Flórez, V.; Pérez-López, R.; Santos, A.; Esquivias, L.

    2011-01-01

    Highlights: ► Phosphogypsum wastes are proposed to reduce CO 2 greenhouse gas emissions. ► Phosphogypsum dissolution with NaOH results in Ca(OH) 2 precipitation and Na 2 SO 4 . ► Aqueous carbonation of Ca(OH) 2 with CO 2 results in the CaCO 3 precipitation. ► Metals contained in the phosphogypsum are transferred to the final calcite. ► Applications of CaCO 3 and Na 2 SiO 4 by-products are proposed to improve viability. - Abstract: Industrial wet phosphoric acid production in Huelva (SW Spain) has led to the controversial stockpiling of waste phosphogypsum by-products, resulting in the release of significant quantities of toxic impurities in salt marshes in the Tinto river estuary. In the framework of the fight against global climate change and the effort to reduce carbon dioxide emissions, a simple and efficient procedure for CO 2 mineral sequestration is presented in this work, using phosphogypsum waste as a calcium source. Our results demonstrate the high efficiency of portlandite precipitation by phosphogypsum dissolution using an alkaline soda solution. Carbonation experiments performed at ambient pressure and temperature resulted in total conversion of the portlandite into carbonate. The fate of trace elements present in the phosphogypsum waste was also investigated, and trace impurities were found to be completely transferred to the final calcite. We believe that the procedure proposed here should be considered not only as a solution for reducing old stockpiles of phosphogypsum wastes, but also for future phosphoric acid and other gypsum-producing industrial processes, resulting in more sustainable production.

  17. Rogue waves and rational solutions of a (3+1)-dimensional nonlinear evolution equation

    International Nuclear Information System (INIS)

    Zhaqilao,

    2013-01-01

    A simple symbolic computation approach for finding the rogue waves and rational solutions to the nonlinear evolution equation is proposed. It turns out that many rational solutions with real and complex forms of a (3+1)-dimensional nonlinear evolution equation are obtained. Some features of rogue waves and rational solutions are graphically discussed. -- Highlights: •A simple symbolic computation approach for finding the rational solutions to the NEE is proposed. •Some rogue waves and rational solutions with real and complex forms of a (3+1)-D NEE are obtained. •Some features of rogue waves are graphically discussed

  18. Rogue waves and rational solutions of a (3+1)-dimensional nonlinear evolution equation

    Energy Technology Data Exchange (ETDEWEB)

    Zhaqilao,, E-mail: zhaqilao@imnu.edu.cn

    2013-12-06

    A simple symbolic computation approach for finding the rogue waves and rational solutions to the nonlinear evolution equation is proposed. It turns out that many rational solutions with real and complex forms of a (3+1)-dimensional nonlinear evolution equation are obtained. Some features of rogue waves and rational solutions are graphically discussed. -- Highlights: •A simple symbolic computation approach for finding the rational solutions to the NEE is proposed. •Some rogue waves and rational solutions with real and complex forms of a (3+1)-D NEE are obtained. •Some features of rogue waves are graphically discussed.

  19. Creep buckling: an experiment, an 'exact' solution and some simple thoughts

    International Nuclear Information System (INIS)

    Heller, P.; Anderson, R.G.

    1986-01-01

    The paper presents attempts to analyse and understand a carefully conducted creep buckling experiment. The analysis was conducted using the ABAQUS Finite Element Code coupled to a number of plausible creep laws. The results show good agreement between ABAQUS runs and experimental deflections but it is difficult to reproduce the early loads. A simple model of buckling analysis for n-power creep laws is derived as an aid to understanding the development of the deflections for non-linear creep laws. In particular, the model suggests why deflections develop so rapidly and how the creep deflection development relates to the elastic behaviour. (author)

  20. The modified simple equation method for solving some fractional ...

    Indian Academy of Sciences (India)

    ... and processes in various areas of natural science. Thus, many effective and powerful methods have been established and improved. In this study, we establish exact solutions of the time fractional biological population model equation and nonlinearfractional Klein–Gordon equation by using the modified simple equation ...

  1. Simple statistical methods for software engineering data and patterns

    CERN Document Server

    Pandian, C Ravindranath

    2015-01-01

    Although there are countless books on statistics, few are dedicated to the application of statistical methods to software engineering. Simple Statistical Methods for Software Engineering: Data and Patterns fills that void. Instead of delving into overly complex statistics, the book details simpler solutions that are just as effective and connect with the intuition of problem solvers.Sharing valuable insights into software engineering problems and solutions, the book not only explains the required statistical methods, but also provides many examples, review questions, and case studies that prov

  2. Procedure and equipment for continuous manufacture of solutions

    International Nuclear Information System (INIS)

    Stiefel, M.

    1979-01-01

    In order to manufacture boric acid solution for reactor commissioning, the heated water is divided into a main and subsidiary flow, and the total amount of the salt is added to the subsidiary flow. Mixing of the main flow with the salt-containing subsidiary flow takes place on a mixing column. Undissolved salt is removed in a hydro-cyclotron. Preheating of the water takes place in a recuperator heat exchanger and a through boiler provides the final temperatures. (HK) [de

  3. Fabrication of compact and stable perovskite films with optimized precursor composition in the fast-growing procedure

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Tanghao; Zhou, Yuanyuan; Hu, Qin; Chen, Ke; Zhang, Yifei; Yang, Wenqiang; Wu, Jiang; Ye, Fengjun; Luo, Deying; Zhu, Kai; Padture, Nitin P.; Liu, Feng; Russell, Thomas; Zhu, Rui; Gong, Qihuang

    2017-06-02

    The fast-growing procedure (FGP) provides a simple, high-yield and lead (Pb)-release free method to prepare perovskite films. In the FGP, the ultra-dilute perovskite precursor solution is drop-cast onto a hot (~240 degrees C) substrate, where a perovskite film grows immediately accompanied by the rapid evaporation of the host solvent. In this process, all the raw materials in the precursor solution are deposited into the final perovskite film. The potential pollution caused by Pb can be significantly reduced. Properties of the FGP-processed perovskite films can be modulated by the precursor composition. While CH3NH3Cl (MACl) affects the crystallization process and leads to full surface coverage, CH(NH2)2I (FAI) enhances the thermal stability of the film. Based on the optimized precursor composition of PbI2(1-x)FAI xMACl, x=0.75, FGP-processed planar heterojunction perovskite solar cells exhibit power conversion efficiencies (PCEs) exceeding 15% with suppressed hysteresis and excellent reproducibility.

  4. Partitioning high-level waste from alkaline solution: A literature survey

    International Nuclear Information System (INIS)

    Marsh, S.F.

    1993-05-01

    Most chemical partitioning procedures are designed for acidic feed solutions. However, the high-level waste solutions in the underground storage tanks at US Department of Energy defense production sites are alkaline. Effective partitioning procedures for alkaline solutions could decrease the need to acidify these solutions and to dissolve the solids in acid, which would simplify subsequent processing and decrease the generation of secondary waste. The author compiles candidate technologies from his review of the chemical literature, experience, and personal contacts. Several of these are recommended for evaluation

  5. A new multi-step technique with differential transform method for analytical solution of some nonlinear variable delay differential equations.

    Science.gov (United States)

    Benhammouda, Brahim; Vazquez-Leal, Hector

    2016-01-01

    This work presents an analytical solution of some nonlinear delay differential equations (DDEs) with variable delays. Such DDEs are difficult to treat numerically and cannot be solved by existing general purpose codes. A new method of steps combined with the differential transform method (DTM) is proposed as a powerful tool to solve these DDEs. This method reduces the DDEs to ordinary differential equations that are then solved by the DTM. Furthermore, we show that the solutions can be improved by Laplace-Padé resummation method. Two examples are presented to show the efficiency of the proposed technique. The main advantage of this technique is that it possesses a simple procedure based on a few straight forward steps and can be combined with any analytical method, other than the DTM, like the homotopy perturbation method.

  6. A simple method to separate red wine nonpolymeric and polymeric phenols by solid-phase extraction.

    Science.gov (United States)

    Pinelo, Manuel; Laurie, V Felipe; Waterhouse, Andrew L

    2006-04-19

    Simple polyphenols and tannins differ in the way that they contribute to the organoleptic profile of wine and their effects on human health. Very few straightforward techniques to separate red wine nonpolymeric phenols from the polymeric fraction are available in the literature. In general, they are complex, time-consuming, and generate large amounts of waste. In this procedure, the separation of these compounds was achieved using C18 cartridges, three solvents with different elution strengths, and pH adjustments of the experimental matrices. Two full factorial 2(3) experimental designs were performed to find the optimal critical variables and their values, allowing for the maximization of tannin recovery and separation efficiency (SE). Nonpolymeric phenols such as phenolic acids, monomers, and oligomers of flavonol and flavan-3-ols and anthocyanins were removed from the column by means of an aqueous solvent followed by ethyl acetate. The polymeric fraction was then eluted with a combination of methanol/acetone/water. The best results were attained with 1 mL of wine sample, a 10% methanol/water solution (first eluant), ethyl acetate (second eluant), and 66% acetone/water as the polymeric phenols-eluting solution (third eluant), obtaining a SE of ca. 90%. Trials with this method on fruit juices also showed high separation efficiency. Hence, this solid-phase extraction method has been shown to be a simple and efficient alternative for the separation of nonpolymeric phenolic fractions and the polymeric ones, and this method could have important applications to sample purification prior to biological testing due to the nonspecific binding of polymeric phenolics to nearly all enzymes and receptor sites.

  7. Hot test of a TALSPEAK procedure for separation of actinides and lanthanides using recirculating DTPA-lactic acid solution

    International Nuclear Information System (INIS)

    Persson, G.; Svantesson, I.; Wingefors, S.; Liljenzin, J.O.

    1984-01-01

    Results are reported from a hot test of a TALSPEAK type process for separation of higher actinides (Am, Cm) from lanthanides. Actinides and lanthanides are extracted by 1 M HDEHP and separated by selective strip of the actinides, using a mixture of DTPA and lactic acid (reversed TALSPEAK process). In order to minimize the generation of secondary waste, a procedure using recirculating DTPA-Lactic acid solution has been developed. A separation factor between Am and Eu of 132 was achieved. In regard to separations of Am and Cm from commercial HLLW (high level liquid wastes), the factor corresponds to 1.5% of the lanthanide group remaining with the actinides. The loss of Am was about 0.2%. 9 figures, 3 tables

  8. A simple theory of LET spectra of heavy ion beams

    International Nuclear Information System (INIS)

    Wilson, J.W.; Townsend, L.W.; Schimmerling, W.; Norbury, J.W.; Wong, M.; Badavi, F.

    1985-01-01

    The transition of high energy ion beams through extended matter is of considerable interest to the space program as well as radiobiology and medical therapy. The transition is defined in terms of various atomic/molecular and nuclear cross sections in a Boltzmann-like equation. One dimensional solutions are derived herein from which LET spectra are derived for secondary fragments. Such LET spectra are fundamental to the evaluation of beam quality, biological effects, and radiation shield effectiveness. Sensitivity of LET spectral distributions to uncertainty in physical parameters such as the isotopic fragmentation parameters, fragment mass, and absorption cross section is established for a number of ion beams. The main limitation in LET studies is the paucity of both elemental and isotopic fragmentation data. The elemental fragmentation data is more readily available because of its simple experimental procedures. It has been suggested by some that natural abundance ratios should be used with the elemental cross sections but this leads to an order-of-magnitude error in LET spectra in many cases. Very few examples of isotopic fragmentation measurements are available. Although major advances in nuclear fragmentation theory have been made, we must await more extensive isotopic fragmentation experiments for final validation

  9. Simple educational tool for digital speckle shearography

    International Nuclear Information System (INIS)

    Schirripa Spagnolo, Giuseppe; Martocchia, Andrea; Papalillo, Donato; Cozzella, Lorenzo

    2012-01-01

    In this study, an educational tool has been prepared for obtaining short-term and more economic training on digital speckle shearography (DSS). Shearography non-destructive testing (NDT) has gained wide acceptance over the last decade, providing a number of important and exciting inspection solutions in aerospace, electronics and medical device manufacturing. For exploring these motivations, it is important to develop didactic tools to understand the potential of digital shearography through training and didactic courses in the field of NDT. In this paper we describe a simple tool for making one familiar with the potential of DSS in the area of education and training. The system is realized with a simple and economic optical setup and a virtual instrument based on the LabVIEW™ and DAQ. (paper)

  10. Simple Parametric Model for Airfoil Shape Description

    Science.gov (United States)

    Ziemkiewicz, David

    2017-12-01

    We show a simple, analytic equation describing a class of two-dimensional shapes well suited for representation of aircraft airfoil profiles. Our goal was to create a description characterized by a small number of parameters with easily understandable meaning, providing a tool to alter the shape with optimization procedures as well as manual tweaks by the designer. The generated shapes are well suited for numerical analysis with 2D flow solving software such as XFOIL.

  11. Inhibition of spontaneous induction of lambdoid prophages in Escherichia coli cultures: simple procedures with possible biotechnological applications

    Directory of Open Access Journals (Sweden)

    Wrobel Borys

    2001-04-01

    Full Text Available Abstract Background Infections of bacterial cultures by bacteriophages are serious problems in biotechnological laboratories. Apart from such infections, prophage induction in the host cells may also be dangerous. Escherichia coli is a commonly used host in biotechnological production, and many laboratory strains of this bacterium harbour lambdoid prophages. These prophages may be induced under certain conditions leading to phage lytic development. This is fatal for further cultivations as relatively low, though still significant, numbers of phages may be overlooked. Thus, subsequent cultures of non-lysogenic strains may be infected and destroyed by such phage. Results Here we report that slow growth of bacteria decreases deleterious effects of spontaneous lambdoid prophage induction. Moreover, replacement of glucose with glycerol in a medium stimulates lysogenic development of the phage after infection of E. coli cells. A plasmid was constructed overexpressing the phage 434 cI gene, coding for the repressor of phage promoters which are necessary for lytic development. Overproduction of the cI repressor abolished spontaneous induction of the λimm434 prophage. Conclusions Simple procedures that alleviate problems with spontaneous induction of lambdoid prophage and subsequent infection of E. coli strains by these phages are described. Low bacterial growth rate, replacement of glucose with glycerol in a medium and overproduction of the cI repressor minimise the risk of prophage induction during cultivation of lysogenic bacteria and subsequent infection of other bacterial strains.

  12. Solute segregation during irradiation

    International Nuclear Information System (INIS)

    Wiedersich, H.; Okamoto, P.R.; Lam, N.Q.

    1977-01-01

    Irradiation at elevated temperature induces redistribution of the elements in alloys on a microstructural level. This phenomenon is caused by differences in the coupling of the various alloy constituents to the radiation-induced defect fluxes. A simple model of the segregation process based on coupled reaction-rate and diffusion equations is discussed. The model gives a good description of the experimentally observed consequences of radiation-induced segregation, including enrichment or depletion of solute elements near defect sinks such as surfaces, voids and dislocations; precipitation of second phases in solid solutions; precipitate redistribution in two-phase alloys; and effects of defect-production rates on void-swelling rates in alloys with minor solute additions

  13. A simple model to estimate the optimal doping of p - Type oxide superconductors

    Directory of Open Access Journals (Sweden)

    Adir Moysés Luiz

    2008-12-01

    Full Text Available Oxygen doping of superconductors is discussed. Doping high-Tc superconductors with oxygen seems to be more efficient than other doping procedures. Using the assumption of double valence fluctuations, we present a simple model to estimate the optimal doping of p-type oxide superconductors. The experimental values of oxygen content for optimal doping of the most important p-type oxide superconductors can be accounted for adequately using this simple model. We expect that our simple model will encourage further experimental and theoretical researches in superconducting materials.

  14. Automated MAD and MIR structure solution

    International Nuclear Information System (INIS)

    Terwilliger, Thomas C.; Berendzen, Joel

    1999-01-01

    A fully automated procedure for solving MIR and MAD structures has been developed using a scoring scheme to convert the structure-solution process into an optimization problem. Obtaining an electron-density map from X-ray diffraction data can be difficult and time-consuming even after the data have been collected, largely because MIR and MAD structure determinations currently require many subjective evaluations of the qualities of trial heavy-atom partial structures before a correct heavy-atom solution is obtained. A set of criteria for evaluating the quality of heavy-atom partial solutions in macromolecular crystallography have been developed. These have allowed the conversion of the crystal structure-solution process into an optimization problem and have allowed its automation. The SOLVE software has been used to solve MAD data sets with as many as 52 selenium sites in the asymmetric unit. The automated structure-solution process developed is a major step towards the fully automated structure-determination, model-building and refinement procedure which is needed for genomic scale structure determinations

  15. Large-area graphene films by simple solution casting of edge-selectively functionalized graphite.

    Science.gov (United States)

    Bae, Seo-Yoon; Jeon, In-Yup; Yang, Jieun; Park, Noejung; Shin, Hyeon Suk; Park, Sungjin; Ruoff, Rodney S; Dai, Liming; Baek, Jong-Beom

    2011-06-28

    We report edge-selective functionalization of graphite (EFG) for the production of large-area uniform graphene films by simply solution-casting EFG dispersions in dichloromethane on silicon oxide substrates, followed by annealing. The resultant graphene films show ambipolar transport properties with sheet resistances of 0.52-3.11 kΩ/sq at 63-90% optical transmittance. EFG allows solution processing methods for the scalable production of electrically conductive, optically transparent, and mechanically robust flexible graphene films for use in practice.

  16. The Krafft temperature of surfactant solutions

    OpenAIRE

    Manojlović Jelena Ž.

    2012-01-01

    Our main motivation to revisit the solution properties of cetyltrimethylammonium bromide is related to the clear requirement for better control of the adsorption parameters to form uniform self-assembled monolayers on muscovite mica substrates. To readily monitor the temporal evolution of structural details in cetyltrimethylammonium bromide solutions, we realized a rather simple conductivity experiment. Conductivity measurements were carried out as a function of temperature, to look clo...

  17. Sweet Solutions to Reduce Procedural Pain in Neonates: A Meta-analysis.

    Science.gov (United States)

    Harrison, Denise; Larocque, Catherine; Bueno, Mariana; Stokes, Yehudis; Turner, Lucy; Hutton, Brian; Stevens, Bonnie

    2017-01-01

    Abundant evidence of sweet taste analgesia in neonates exists, yet placebo-controlled trials continue to be conducted. To review all trials evaluating sweet solutions for analgesia in neonates and to conduct cumulative meta-analyses (CMAs) on behavioral pain outcomes. (1) Data from 2 systematic reviews of sweet solutions for newborns; (2) searches ending 2015 of CINAHL, Medline, Embase, and psychINFO. Two authors screened studies for inclusion, conducted risk-of-bias ratings, and extracted behavioral outcome data for CMAs. CMA was performed using random effects meta-analysis. One hundred and sixty-eight studies were included; 148 (88%) included placebo/no-treatment arms. CMA for crying time included 29 trials (1175 infants). From the fifth trial in 2002, there was a statistically significant reduction in mean cry time for sweet solutions compared with placebo (-27 seconds, 95% confidence interval [CI] -51 to -4). By the final trial, CMA was -23 seconds in favor of sweet solutions (95% CI -29 to -18). CMA for pain scores included 50 trials (3341 infants). Results were in favor of sweet solutions from the second trial (0.5, 95% CI -1 to -0.1). Final results showed a standardized mean difference of -0.9 (95% CI -1.1 to -0.7). We were unable to use or obtain data from many studies to include in the CMA. Evidence of sweet taste analgesia in neonates has existed since the first published trials, yet placebo/no-treatment, controlled trials have continued to be conducted. Future neonatal pain studies need to select more ethically responsible control groups. Copyright © 2017 by the American Academy of Pediatrics.

  18. Removal of copper (II) from aqueous solutions by flotation using polyaluminum chloride silicate (PAX-XL60 S) as coagulant and carbonate ion as activator.

    Science.gov (United States)

    Ghazy, S E; Mahmoud, I A; Ragab, A H

    2006-01-01

    Flotation is a separation technology for removing toxic heavy metal ions from aqueous solutions. Here a simple and rapid flotation procedure is presented for the removal of copper(II) from aqueous solutions. It is based on the use of polyaluminum chloride silicate (PAX-XL60 S) as coagulant and flocculent, carbonate ion as activator and oleic acid (HOL) as surfactant. Both ion and precipitate flotation are included depending on the solution pH. Ion and precipitate flotation in the aqueous HOL-PAX-XL60 S-Cu2+-CO3(2-) system gave powerful preferential removal of Cu2+ (F -100%) over the HOL-PAX-XL60 S-Cu2+ system containing no CO3(2+) ion (F approximately 86%). The role of CO3(2-) ion is also evident from decreasing the dose of PAX-XL60 S from 700 mg l(-1) to 200 mg l(-1). The other parameters, influencing the flotation process, namely: metal ion, surfactant and PAX-XL60 S concentrations, ionic strength, temperature and foreign ions were examined. Moreover, the procedure was successfully applied to recover Cu2+ ions from different volumes up to 11 and from natural water samples.

  19. Business Intelligence Integrated Solutions

    Directory of Open Access Journals (Sweden)

    Cristescu Marian Pompiliu

    2017-12-01

    Full Text Available A Business Intelligence solution concerns the simple, real-time access to complete information about the business shown in a relevant format of the report, graphic or dashboard type in order help the taking of strategic decisions regarding the direction in which the company goes. Business Intelligence does not produce data, but uses the data produced by the company’s applications. BI solutions extract their data from ERP (Enterprise Resource Planning, CRM (Customer Relationship Management, HCM (Human Capital Management, and Retail, eCommerce or other databases used in the company.

  20. Exact solutions for modified Korteweg-de Vries equation

    International Nuclear Information System (INIS)

    Sarma, Jnanjyoti

    2009-01-01

    Using the simple wave or traveling wave solution technique, many different types of solutions are derived for modified Korteweg-de Vries (KdV) equation. The solutions are obtained from the set of nonlinear algebraic equations, which can be derived from the modified Korteweg-de Vries (KdV) equation by using the hyperbolic transformation method. The method can be applicable for similar nonlinear wave equations.

  1. Exact interior solutions in 2 + 1-dimensional spacetime

    Energy Technology Data Exchange (ETDEWEB)

    Rahaman, Farook; Bhar, Piyali [Jadavpur University, Department of Mathematics, Kolkata, West Bengal (India); Biswas, Ritabrata [Indian Institute of Engineering Sceince and Technology Shibpur, Howrah, West Bengal (India); Usmani, A.A. [Aligarh Muslim University, Department of Physics, Aligarh, Uttar Pradesh (India)

    2014-04-15

    We provide a new class of exact solutions for the interior in 2 + 1-dimensional spacetime. The solutions obtained for the perfect fluid model both with and without cosmological constant (Λ) are found to be regular and singularity free. It assumes very simple analytical forms that help us to study the various physical properties of the configuration. Solutions without Λ are found to be physically acceptable. (orig.)

  2. Simple and inexpensive microfluidic devices for the generation of monodisperse multiple emulsions

    KAUST Repository

    Li, Erqiang; Zhang, Jiaming; Thoroddsen, Sigurdur T

    2013-01-01

    of expensive apparatus and a complex manufacturing procedure. Here, we report the design and fabrication of simple and inexpensive microfluidic devices based on microscope glass slides and pulled glass capillaries, for generating monodisperse multiple emulsions

  3. Inequality and Procedural Justice in Social Dilemmas

    NARCIS (Netherlands)

    Aksoy, Ozan; Weesie, Jeroen

    2009-01-01

    This study investigates the influence of resource inequality and the fairness of the allocation procedure of unequal resources on cooperative behavior in social dilemmas. We propose a simple formal behavioral model that incorporates conflicting selfish and social motivations. This model allows us to

  4. The Improvement of Simple Explanation and Inferencetion Skills with Problem Solving

    OpenAIRE

    Dewanti, Fransiska Olivia; Diawati, Chansyanah; Fadiawati, Noor

    2013-01-01

    The learning process is strongly influenced by the ability and accuracy of teachers in selecting and applying the learning model. The model can be applied to improve of  simple explanation and inferencetion skill is a model of problem solving. The purpose of this study was to describe the model of problem solving that are effective in improving simple explanation and inferencetion skills on the material electrolyte and non-electrolyte solution. This research use a quasi-experimental methods ...

  5. Formalizing physical security procedures

    NARCIS (Netherlands)

    Meadows, C.; Pavlovic, Dusko

    Although the problems of physical security emerged more than 10,000 years before the problems of computer security, no formal methods have been developed for them, and the solutions have been evolving slowly, mostly through social procedures. But as the traffic on physical and social networks is now

  6. A simple formula for the conserved charges of soliton theories

    International Nuclear Information System (INIS)

    Ferreira, Luiz Agostinho; Zakrzewski, Wojtek J.

    2007-01-01

    We present a simple formula for all the conserved charges of soliton theories, evaluated on the solutions belonging to the orbit of the vacuum under the group of dressing transformations. For pedagogical reasons we perform the explicit calculations for the case of the sine-Gordon model, taken as a prototype of soliton theories. We show that the energy and momentum are boundary terms for all the solutions on the orbit of the vacuum. That orbit includes practically all the solutions of physical interest, namely solitons, multi-solitons, breathers, and combinations of solitons and breathers. The example of the mKdV equation is also given explicitly

  7. The benefits of using customized procedure packs.

    Science.gov (United States)

    Baines, R; Colquhoun, G; Jones, N; Bateman, R

    2001-01-01

    Discrete item purchasing is the traditional approach for hospitals to obtain consumable supplies for theatre procedures. Although most items are relatively low cost, the management and co-ordination of the supply chain, raising orders, controlling stock, picking and delivering to each operating theatre can be complex and costly. Customized procedure packs provide a solution.

  8. A comprehensive analytical solution of the nonlinear pendulum

    International Nuclear Information System (INIS)

    Ochs, Karlheinz

    2011-01-01

    In this paper, an analytical solution for the differential equation of the simple but nonlinear pendulum is derived. This solution is valid for any time and is not limited to any special initial instance or initial values. Moreover, this solution holds if the pendulum swings over or not. The method of approach is based on Jacobi elliptic functions and starts with the solution of a pendulum that swings over. Due to a meticulous sign correction term, this solution is also valid if the pendulum does not swing over.

  9. Reactant-solute encounters in aqueous solutions studied by kinetic methods: hydration cosphere overlap and camouflage effects : hydration cosphere overlap and camouflage effects

    NARCIS (Netherlands)

    Engberts, Jan B.F.N.; Blandamer, Michael J.

    1998-01-01

    Rates of chemical reactions in aqueous solutions are often sensitive to low concentrations of added solutes such as ureas, alcohols, α-amino acids and carbohydrates. In this work, several simple chemical reactions were used to probe this sensitivity, which arises from interactions between added

  10. A simple model for electrical charge in globular macromolecules and linear polyelectrolytes in solution

    Science.gov (United States)

    Krishnan, M.

    2017-05-01

    We present a model for calculating the net and effective electrical charge of globular macromolecules and linear polyelectrolytes such as proteins and DNA, given the concentration of monovalent salt and pH in solution. The calculation is based on a numerical solution of the non-linear Poisson-Boltzmann equation using a finite element discretized continuum approach. The model simultaneously addresses the phenomena of charge regulation and renormalization, both of which underpin the electrostatics of biomolecules in solution. We show that while charge regulation addresses the true electrical charge of a molecule arising from the acid-base equilibria of its ionizable groups, charge renormalization finds relevance in the context of a molecule's interaction with another charged entity. Writing this electrostatic interaction free energy in terms of a local electrical potential, we obtain an "interaction charge" for the molecule which we demonstrate agrees closely with the "effective charge" discussed in charge renormalization and counterion-condensation theories. The predictions of this model agree well with direct high-precision measurements of effective electrical charge of polyelectrolytes such as nucleic acids and disordered proteins in solution, without tunable parameters. Including the effective interior dielectric constant for compactly folded molecules as a tunable parameter, the model captures measurements of effective charge as well as published trends of pKa shifts in globular proteins. Our results suggest a straightforward general framework to model electrostatics in biomolecules in solution. In offering a platform that directly links theory and experiment, these calculations could foster a systematic understanding of the interrelationship between molecular 3D structure and conformation, electrical charge and electrostatic interactions in solution. The model could find particular relevance in situations where molecular crystal structures are not available or

  11. Ranking multiple docking solutions based on the conservation of inter-residue contacts

    KAUST Repository

    Oliva, Romina M.

    2013-06-17

    Molecular docking is the method of choice for investigating the molecular basis of recognition in a large number of functional protein complexes. However, correctly scoring the obtained docking solutions (decoys) to rank native-like (NL) conformations in the top positions is still an open problem. Herein we present CONSRANK, a simple and effective tool to rank multiple docking solutions, which relies on the conservation of inter-residue contacts in the analyzed decoys ensemble. First it calculates a conservation rate for each inter-residue contact, then it ranks decoys according to their ability to match the more frequently observed contacts. We applied CONSRANK to 102 targets from three different benchmarks, RosettaDock, DOCKGROUND, and Critical Assessment of PRedicted Interactions (CAPRI). The method performs consistently well, both in terms of NL solutions ranked in the top positions and of values of the area under the receiver operating characteristic curve. Its ideal application is to solutions coming from different docking programs and procedures, as in the case of CAPRI targets. For all the analyzed CAPRI targets where a comparison is feasible, CONSRANK outperforms the CAPRI scorers. The fraction of NL solutions in the top ten positions in the RosettaDock, DOCKGROUND, and CAPRI benchmarks is enriched on average by a factor of 3.0, 1.9, and 9.9, respectively. Interestingly, CONSRANK is also able to specifically single out the high/medium quality (HMQ) solutions from the docking decoys ensemble: it ranks 46.2 and 70.8% of the total HMQ solutions available for the RosettaDock and CAPRI targets, respectively, within the top 20 positions. © 2013 Wiley Periodicals, Inc.

  12. Simple picture for neutrino flavor transformation in supernovae

    Science.gov (United States)

    Duan, Huaiyu; Fuller, George M.; Qian, Yong-Zhong

    2007-10-01

    We can understand many recently discovered features of flavor evolution in dense, self-coupled supernova neutrino and antineutrino systems with a simple, physical scheme consisting of two quasistatic solutions. One solution closely resembles the conventional, adiabatic single-neutrino Mikheyev-Smirnov-Wolfenstein (MSW) mechanism, in that neutrinos and antineutrinos remain in mass eigenstates as they evolve in flavor space. The other solution is analogous to the regular precession of a gyroscopic pendulum in flavor space, and has been discussed extensively in recent works. Results of recent numerical studies are best explained with combinations of these solutions in the following general scenario: (1) Near the neutrino sphere, the MSW-like many-body solution obtains. (2) Depending on neutrino vacuum mixing parameters, luminosities, energy spectra, and the matter density profile, collective flavor transformation in the nutation mode develops and drives neutrinos away from the MSW-like evolution and toward regular precession. (3) Neutrino and antineutrino flavors roughly evolve according to the regular precession solution until neutrino densities are low. In the late stage of the precession solution, a stepwise swapping develops in the energy spectra of νe and νμ/ντ. We also discuss some subtle points regarding adiabaticity in flavor transformation in dense-neutrino systems.

  13. On the generation of magnetostatic solutions from gravitational two-soliton solutions of a stationary mass

    Energy Technology Data Exchange (ETDEWEB)

    Chaudhuri, A. [B.K.C. College, Department of Physics, Kolkata (India); Chaudhuri, S. [University of Burdwan, Department of Physics, Burdwan (India)

    2017-11-15

    In the paper, magnetostatic solutions of the Einstein-Maxwell field equations are generated from the gravitational two-soliton solutions of a stationary mass. Using the soliton technique of Belinskii and Zakharov (Sov Phys JETP 48:985, 1978, Sov Phys JETP 50:1, 1979), we construct diagonal two-soliton solutions of Einstein's gravitational field equations for an axially symmetric stationary space-time and investigate some properties of the generated stationary gravitational metric. Magnetostatic solutions corresponding to the generated stationary gravitational solutions are then constructed using the transformation technique of Das and Chaudhuri (Pramana J Phys 40:277, 1993). The mass and the dipole moment of the source are evaluated. In our analysis we make use of a second transformation (Chaudhuri in Pramana J Phys 58:449, 2002), probably for the first time in the literature, to generate magnetostatic solutions from the stationary gravitational two-soliton solutions which give us simple and straightforward expressions for the mass and the magnetic dipole moment. (orig.)

  14. Flotation separation of hafnium(IV) from aqueous solutions

    International Nuclear Information System (INIS)

    Downey, D.M.; Narick, C.N.; Cohen, T.A.

    1985-01-01

    A simple, rapid method for the separation of hafnium from aqueous solutions was investigated using sup(175+181)Hf tracer. Cationic hafnium complex ions were floated from dilute acid solutions with sodium lauryl sulfate (SLS) and anionic hafnium complexes were floated from basic and oxalic acid solutions with hexadecyltrimethyl ammonium bromide (HTMAB). The conditions necessary for quantitative recovery of the metal and mechanisms of flotation are described. (author)

  15. Amperometric titration of indium with edta solution in propanol

    International Nuclear Information System (INIS)

    Gevorgyan, A.M.; Talipov, Sh.T.; Khadeev, V.A.; Kostylev, V.S.; Khadeeva, L.A.

    1980-01-01

    Optimum conditions have been chosen for titration of indium with EDTA solution in anhydrous propanol and its mixtures with some aprotic solvents using amperometric and point detection. A procedure is suggested of determining indium microcontents in the presence of large amounts of other elements. The procedure is based on its extraction preseparation followed by direct titration in the extract with a standard EDTA solution [ru

  16. Classification of homoclinic rogue wave solutions of the nonlinear Schrödinger equation

    Science.gov (United States)

    Osborne, A. R.

    2014-01-01

    Certain homoclinic solutions of the nonlinear Schrödinger (NLS) equation, with spatially periodic boundary conditions, are the most common unstable wave packets associated with the phenomenon of oceanic rogue waves. Indeed the homoclinic solutions due to Akhmediev, Peregrine and Kuznetsov-Ma are almost exclusively used in scientific and engineering applications. Herein I investigate an infinite number of other homoclinic solutions of NLS and show that they reduce to the above three classical homoclinic solutions for particular spectral values in the periodic inverse scattering transform. Furthermore, I discuss another infinity of solutions to the NLS equation that are not classifiable as homoclinic solutions. These latter are the genus-2N theta function solutions of the NLS equation: they are the most general unstable spectral solutions for periodic boundary conditions. I further describe how the homoclinic solutions of the NLS equation, for N = 1, can be derived directly from the theta functions in a particular limit. The solutions I address herein are actual spectral components in the nonlinear Fourier transform theory for the NLS equation: The periodic inverse scattering transform. The main purpose of this paper is to discuss a broader class of rogue wave packets1 for ship design, as defined in the Extreme Seas program. The spirit of this research came from D. Faulkner (2000) who many years ago suggested that ship design procedures, in order to take rogue waves into account, should progress beyond the use of simple sine waves. 1An overview of other work in the field of rogue waves is given elsewhere: Osborne 2010, 2012 and 2013. See the books by Olagnon and colleagues 2000, 2004 and 2008 for the Brest meetings. The books by Kharif et al. (2008) and Pelinovsky et al. (2010) are excellent references.

  17. Solving the AKNS Hierarchy by Its Bilinear Form: Generalized Double Wronskian Solutions

    International Nuclear Information System (INIS)

    Yin Fumei; Sun Yepeng; Cai Fuqing; Chen Dengyuan

    2008-01-01

    Through the Wronskian technique, a simple and direct proof is presented that the AKNS hierarchy in the bilinear form has generalized double Wronskian solutions. Moreover, by using a unified way, soliton solutions, rational solutions, Matveev solutions and complexitons in double Wronskian form for it are constructed.

  18. Fuzzy logic: A "simple" solution for complexities in neurosciences?

    Science.gov (United States)

    Godil, Saniya Siraj; Shamim, Muhammad Shahzad; Enam, Syed Ather; Qidwai, Uvais

    2011-02-26

    Fuzzy logic is a multi-valued logic which is similar to human thinking and interpretation. It has the potential of combining human heuristics into computer-assisted decision making, which is applicable to individual patients as it takes into account all the factors and complexities of individuals. Fuzzy logic has been applied in all disciplines of medicine in some form and recently its applicability in neurosciences has also gained momentum. This review focuses on the use of this concept in various branches of neurosciences including basic neuroscience, neurology, neurosurgery, psychiatry and psychology. The applicability of fuzzy logic is not limited to research related to neuroanatomy, imaging nerve fibers and understanding neurophysiology, but it is also a sensitive and specific tool for interpretation of EEGs, EMGs and MRIs and an effective controller device in intensive care units. It has been used for risk stratification of stroke, diagnosis of different psychiatric illnesses and even planning neurosurgical procedures. In the future, fuzzy logic has the potential of becoming the basis of all clinical decision making and our understanding of neurosciences.

  19. Implementing Distributed Algorithms using Remote Procedure Call

    NARCIS (Netherlands)

    Bal, H.E.; van Renesse, R.; Tanenbaum, A.S.

    1987-01-01

    Remote procedure call (RPC) is a simple yet powerful primitiv~ for communication and synchronization between distributed processes. A problem with RPC is that it tends to decrease the amount of parallelism in an application due to its synchronous nature. This paper shows how light-weight processes

  20. Comparison of simple extraction procedures in liquid chromatography-mass spectrometry based determination of serum 7α-hydroxy-4-cholesten-3-one, a surrogate marker of bile acid synthesis.

    Science.gov (United States)

    LeníĿek, Martin; Vecka, Marek; Žížalová, Kateſina; Vítek, Libor

    2016-10-15

    The serum concentration of 7α-hydroxy-4-cholesten-3-one (C4), a marker of cholesterol 7α-hydroxylase activity, has recently become an attractive diagnostic tool for researchers interested in cholesterol and bile acid metabolism. The rapidly increasing demand of C4 measurement led to the development of various fast, mostly mass spectrometry-based analytical methods. Our aim was to compare four simple (i.e., not requiring solid phase extraction) extraction procedures (two "one-phase", and two "two-phase") in terms of basic analytical performance and their labouriousness. All methods exhibited comparable extraction recoveries (ranging from 88 to 97%) and intra-assay precision (variation coefficients below 10%), and failed in the removal of phospholipids. Although marked differences were observed in desalting and deproteination, all methods can be considered satisfactory. Simple acetonitrile precipitation can be recommended if a fast extraction and minimal hands-on time is preferred; while two-phase ammonium sulphate:acetonitrile extraction should be chosen when maximal deproteination is required. Copyright © 2016 Elsevier B.V. All rights reserved.

  1. Holomorphic Vector Bundles Corresponding to some Soliton Solutions of the Ward Equation

    Energy Technology Data Exchange (ETDEWEB)

    Zhu, Xiujuan, E-mail: yzzhuxiujuan@sina.com [Jiangsu Second Normal University, School of Mathematics and Information Technology (China)

    2015-12-15

    Holomorphic vector bundles corresponding to the static soliton solution of the Ward equation were explicitly presented by Ward in terms of a meromorphic framing. Bundles (for simplicity, “bundle” is to be taken throughout to mean “holomorphic vector bundle”) corresponding to all Ward k-soliton solutions whose extended solutions have only simple poles, and some Ward 2-soliton solutions whose extended solutions have only a second-order pole, were explicitly described by us in a previous paper. In this paper, we go on to present some bundles corresponding to soliton-antisoliton solutions of the Ward equation, and Ward 3-soliton solutions whose extended solutions have a simple pole and a double pole. To give some more interpretation of the bundles, we study the second Chern number of the corresponded bundles and find that it can be obtained directly from the patching matrices. We also point out some information about bundles corresponding to Ward soliton solutions whose extended solutions have general pole data at the end of the paper.

  2. Multidimensional Gravitational Models: Fluxbrane and S-Brane Solutions with Polynomials

    International Nuclear Information System (INIS)

    Ivashchuk, V. D.; Melnikov, V. N.

    2007-01-01

    Main results in obtaining exact solutions for multidimensional models and their application to solving main problems of modern cosmology and black hole physics are described. Some new results on composite fluxbrane and S-brane solutions for a wide class of intersection rules are presented. These solutions are defined on a product manifold R* x M1 x ... x Mn which contains n Ricci-flat spaces M1,...,Mn with 1-dimensional R* and M1. They are defined up to a set of functions obeying non-linear differential equations equivalent to Toda-type equations with certain boundary conditions imposed. Exact solutions corresponding to configurations with two branes and intersections related to simple Lie algebras C2 and G2 are obtained. In these cases the functions Hs(z), s = 1, 2, are polynomials of degrees: (3, 4) and (6, 10), respectively, in agreement with a conjecture suggested earlier. Examples of simple S-brane solutions describing an accelerated expansion of a certain factor-space are given explicitely

  3. On numerical solution of Burgers' equation by homotopy analysis method

    International Nuclear Information System (INIS)

    Inc, Mustafa

    2008-01-01

    In this Letter, we present the Homotopy Analysis Method (shortly HAM) for obtaining the numerical solution of the one-dimensional nonlinear Burgers' equation. The initial approximation can be freely chosen with possible unknown constants which can be determined by imposing the boundary and initial conditions. Convergence of the solution and effects for the method is discussed. The comparison of the HAM results with the Homotopy Perturbation Method (HPM) and the results of [E.N. Aksan, Appl. Math. Comput. 174 (2006) 884; S. Kutluay, A. Esen, Int. J. Comput. Math. 81 (2004) 1433; S. Abbasbandy, M.T. Darvishi, Appl. Math. Comput. 163 (2005) 1265] are made. The results reveal that HAM is very simple and effective. The HAM contains the auxiliary parameter h, which provides us with a simple way to adjust and control the convergence region of solution series. The numerical solutions are compared with the known analytical and some numerical solutions

  4. Proposal of a simple screening method for a rapid preliminary evaluation of ''heavy metals'' mobility in soils of contaminated sites

    Energy Technology Data Exchange (ETDEWEB)

    Pinto, Valentina; Chiusolo, Francesca; Cremisini, Carlo [ENEA - Italian Agency for New Technologies, Energy and Environment, Rome (Italy). Section PROTCHIM

    2010-09-15

    Risks associated to ''heavy metals'' (HM) soil contamination depend not only on their total content but, mostly, on their mobility. Many extraction procedures have been developed to evaluate HM mobility in contaminated soils, but they are generally time consuming (especially the sequential extraction procedures (SEPs)) and consequently applicable on a limited number of samples. For this reason, a simple screening method, applicable even ''in field'', has been proposed in order to obtain a rapid evaluation of HM mobility in polluted soils, mainly focused on the fraction associated to Fe and Mn oxide/hydroxides. A buffer solution of trisodium citrate and hydroxylamine hydrochloride was used as extractant for a single-step leaching test. The choice of this buffered solution was strictly related to the possibility of directly determining, via titration with dithizone (DZ), the content of Zn, Cu, Pb and Cd, which are among the most representative contaminants in highly mineralised soils. Moreover, the extraction solution is similar, aside from for the pH value, which is the one used in the BCR SEP second step. The analysis of bivalents ions through DZ titration was exploited in order to further simplify and quicken the whole procedure. The proposed method generically measures, in few minutes, the concentration of total extractable ''heavy metals'' expressed as molL{sup -1} without distinguishing between elements. The proposed screening method has been developed and applied on soil samples collected from rural, urban and mining areas, representing different situation of soil contamination. Results were compared with data obtained from the BCR procedure. The screening method demonstrated to be a reliable tool for a rapid evaluation of metals mobility. Therefore, it could be very useful, even ''in field'', both to guide the sampling activity on site and to monitor the efficacy of the subsequent

  5. SPORTS - a simple non-linear thermalhydraulic stability code

    International Nuclear Information System (INIS)

    Chatoorgoon, V.

    1986-01-01

    A simple code, called SPORTS, has been developed for two-phase stability studies. A novel method of solution of the finite difference equations was deviced and incorporated, and many of the approximations that are common in other stability codes are avoided. SPORTS is believed to be accurate and efficient, as small and large time-steps are permitted, and hence suitable for micro-computers. (orig.)

  6. Simple and convenient method for culturing anaerobic bacteria.

    OpenAIRE

    Behbehani, M J; Jordan, H V; Santoro, D L

    1982-01-01

    A simple and convenient method for culturing anaerobic bacteria is described. Cultures can be grown in commercially available flasks normally used for preparation of sterile external solutions. A special disposable rubber flask closure maintains anaerobic conditions in the flask after autoclaving. Growth of a variety of anaerobic oral bacteria was comparable to that obtained after anaerobic incubation of broth cultures in Brewer Anaerobic Jars.

  7. Solidification method for organic solution and processing method of aqueous solution

    International Nuclear Information System (INIS)

    Kamoshida, Mamoru; Fukazawa, Tetsuo; Yazawa, Noriko; Hasegawa, Toshihiko

    1998-01-01

    The relative dielectric constant of an organic solution containing polar ingredients is controlled to 13 or less to enable its solidification. The polarity of the organic solution can be evaluated quantitatively by using the relative dielectric constant. If the relative dielectric constant is high, it can be controlled by dilution using a non-polar organic solvent of low relative dielectric constant. With such procedures, solidification can be conducted by using an economical 12-hydroxy stearic acid, process of liquid wastes can be facilitated and the safety can be ensured. (T.M.)

  8. A simple high performance liquid chromatography method for analyzing paraquat in soil solution samples.

    Science.gov (United States)

    Ouyang, Ying; Mansell, Robert S; Nkedi-Kizza, Peter

    2004-01-01

    A high performance liquid chromatography (HPLC) method with UV detection was developed to analyze paraquat (1,1'-dimethyl-4,4'-dipyridinium dichloride) herbicide content in soil solution samples. The analytical method was compared with the liquid scintillation counting (LSC) method using 14C-paraquat. Agreement obtained between the two methods was reasonable. However, the detection limit for paraquat analysis was 0.5 mg L(-1) by the HPLC method and 0.05 mg L(-1) by the LSC method. The LSC method was, therefore, 10 times more precise than the HPLC method for solution concentrations less than 1 mg L(-1). In spite of the high detection limit, the UC (nonradioactive) HPLC method provides an inexpensive and environmentally safe means for determining paraquat concentration in soil solution compared with the 14C-LSC method.

  9. A new procedure for making TEM specimens of superconductor devices

    International Nuclear Information System (INIS)

    Huang, Y.; Merkle, K.L.

    1997-04-01

    A new procedure is developed for making TEM specimens of thin film devices. In this procedure the sample is flatly polished to an overall ion-mill-ready thickness so that any point in the 2-D sample pane can be thinned to an electron-transparent thickness by subsequent ion-milling. Using this procedure, small regions of interest can be easily reached in both cross-section and plan-view samples. This is especially useful in device studies. Applications of this procedure to the study of superconductor devices yield good results. This procedure, using commercially available equipment and relatively cheap materials, is simple and easy to realize

  10. Flotation separation of hafnium(IV) from aqueous solutions

    Energy Technology Data Exchange (ETDEWEB)

    Downey, D.M.; Narick, C.N.; Cohen, T.A.

    1985-09-01

    A simple, rapid method for the separation of hafnium from aqueous solutions was investigated using sup(175 + 181)Hf tracer. Cationic hafnium complex ions were floated from dilute acid solutions with sodium lauryl sulfate (SLS) and anionic hafnium complexes were floated from basic and oxalic acid solutions with hexadecyltrimethyl ammonium bromide (HTMAB). The conditions necessary for quantitative recovery of the metal and mechanisms of flotation are described. (author). 21 refs.; 5 figs.

  11. A simple application of the Newman-Penrose spin coefficient formalism

    International Nuclear Information System (INIS)

    Davis, T.M.

    1976-01-01

    A simple application of the Newman-Penrose formalism is given which can be used by those learning this theory. The spherically symmetric Einstein-Maxwell problem for the Reissner-Nordstrom solution is solved using the Newman-Penrose formalism. The calculation is carried out using a Minkowski null tetrad. (author)

  12. A simple and optimal ancestry labeling scheme for trees

    DEFF Research Database (Denmark)

    Dahlgaard, Søren; Knudsen, Mathias Bæk Tejs; Rotbart, Noy Galil

    2015-01-01

    We present a lg n + 2 lg lg n + 3 ancestry labeling scheme for trees. The problem was first presented by Kannan et al. [STOC 88’] along with a simple 2 lg n solution. Motivated by applications to XML files, the label size was improved incrementally over the course of more than 20 years by a series...

  13. Simple Extraction and Molecular Weight Characterization of Fucoidan From Indonesian Sargassum SP.

    OpenAIRE

    Junaidi, Lukman

    2013-01-01

    Fucoidan is a complex polysaccharide compounds found in brown algae. Fucoidan exhibits various biological properties for disease prevention. There are various methods used to extract fucoidan from brown algae, such as using ethanol, acetone, HCl and microwave. This research aims to extract and characterize fucoidan from Sargassum sp. using simple methods with the variables on extracting solutions, temperature and time of extraction. Extraction solution used were water and HCl. Ttemperature us...

  14. Simple equation method for nonlinear partial differential equations and its applications

    Directory of Open Access Journals (Sweden)

    Taher A. Nofal

    2016-04-01

    Full Text Available In this article, we focus on the exact solution of the some nonlinear partial differential equations (NLPDEs such as, Kodomtsev–Petviashvili (KP equation, the (2 + 1-dimensional breaking soliton equation and the modified generalized Vakhnenko equation by using the simple equation method. In the simple equation method the trial condition is the Bernoulli equation or the Riccati equation. It has been shown that the method provides a powerful mathematical tool for solving nonlinear wave equations in mathematical physics and engineering problems.

  15. An Inexpensive Solution Calorimeter

    Science.gov (United States)

    Kavanagh, Emma; Mindel, Sam; Robertson, Giles; Hughes, D. E. Peter

    2008-01-01

    We describe the construction of a simple solution calorimeter, using a miniature bead thermistor as a temperature-sensing element. This has a response time of a few seconds and made it possible to carry out a thermometric reaction in under a minute, which led to minimal heat losses. Small temperature changes of 1 K associated with enthalpies of…

  16. On exact solutions of scattering problems

    International Nuclear Information System (INIS)

    Nikishov, P.Yu.; Plekhanov, E.B.; Zakhariev, B.N.

    1982-01-01

    Examples illustrating the quality of the reconstruction of potentials from single-channel scattering data by using exactly solvable models are given. Simple exact solutions for multi-channel systems with non-degenerated resonance singularities of the scattering matrix are derived

  17. Pitfall in quantum mechanical/molecular mechanical molecular dynamics simulation of small solutes in solution.

    Science.gov (United States)

    Hu, Hao; Liu, Haiyan

    2013-05-30

    Developments in computing hardware and algorithms have made direct molecular dynamics simulation with the combined quantum mechanical/molecular mechanical methods affordable for small solute molecules in solution, in which much improved accuracy can be obtained via the quantum mechanical treatment of the solute molecule and even sometimes water molecules in the first solvation shell. However, unlike the conventional molecular mechanical simulations of large molecules, e.g., proteins, in solutions, special care must be taken in the technical details of the simulation, including the thermostat of the solute/solvent system, so that the conformational space of the solute molecules can be properly sampled. We show here that the common setup for classical molecular mechanical molecular dynamics simulations, such as the Berendsen or single Nose-Hoover thermostat, and/or rigid water models could lead to pathological sampling of the solutes' conformation. In the extreme example of a methanol molecule in aqueous solution, improper and sluggish setups could generate two peaks in the distribution of the O-H bond length. We discuss the factors responsible for this somewhat unexpected result and evoke a simple and ancient technical fix-up to resolve this problem.

  18. Evolutionary Statistical Procedures

    CERN Document Server

    Baragona, Roberto; Poli, Irene

    2011-01-01

    This proposed text appears to be a good introduction to evolutionary computation for use in applied statistics research. The authors draw from a vast base of knowledge about the current literature in both the design of evolutionary algorithms and statistical techniques. Modern statistical research is on the threshold of solving increasingly complex problems in high dimensions, and the generalization of its methodology to parameters whose estimators do not follow mathematically simple distributions is underway. Many of these challenges involve optimizing functions for which analytic solutions a

  19. A simple approximation for the current-voltage characteristics of high-power, relativistic diodes

    Energy Technology Data Exchange (ETDEWEB)

    Ekdahl, Carl, E-mail: cekdahl@lanl.gov [Los Alamos National Laboratory, Los Alamos, New Mexico 87545 (United States)

    2016-06-15

    A simple approximation for the current-voltage characteristics of a relativistic electron diode is presented. The approximation is accurate from non-relativistic through relativistic electron energies. Although it is empirically developed, it has many of the fundamental properties of the exact diode solutions. The approximation is simple enough to be remembered and worked on almost any pocket calculator, so it has proven to be quite useful on the laboratory floor.

  20. A Simple Model for Nonlinear Confocal Ultrasonic Beams

    Science.gov (United States)

    Zhang, Dong; Zhou, Lin; Si, Li-Sheng; Gong, Xiu-Fen

    2007-01-01

    A confocally and coaxially arranged pair of focused transmitter and receiver represents one of the best geometries for medical ultrasonic imaging and non-invasive detection. We develop a simple theoretical model for describing the nonlinear propagation of a confocal ultrasonic beam in biological tissues. On the basis of the parabolic approximation and quasi-linear approximation, the nonlinear Khokhlov-Zabolotskaya-Kuznetsov (KZK) equation is solved by using the angular spectrum approach. Gaussian superposition technique is applied to simplify the solution, and an analytical solution for the second harmonics in the confocal ultrasonic beam is presented. Measurements are performed to examine the validity of the theoretical model. This model provides a preliminary model for acoustic nonlinear microscopy.

  1. Collected radiochemical and geochemical procedures

    Energy Technology Data Exchange (ETDEWEB)

    Kleinberg, J [comp.

    1990-05-01

    This revision of LA-1721, 4th Ed., Collected Radiochemical Procedures, reflects the activities of two groups in the Isotope and Nuclear Chemistry Division of the Los Alamos National Laboratory: INC-11, Nuclear and radiochemistry; and INC-7, Isotope Geochemistry. The procedures fall into five categories: I. Separation of Radionuclides from Uranium, Fission-Product Solutions, and Nuclear Debris; II. Separation of Products from Irradiated Targets; III. Preparation of Samples for Mass Spectrometric Analysis; IV. Dissolution Procedures; and V. Geochemical Procedures. With one exception, the first category of procedures is ordered by the positions of the elements in the Periodic Table, with separate parts on the Representative Elements (the A groups); the d-Transition Elements (the B groups and the Transition Triads); and the Lanthanides (Rare Earths) and Actinides (the 4f- and 5f-Transition Elements). The members of Group IIIB-- scandium, yttrium, and lanthanum--are included with the lanthanides, elements they resemble closely in chemistry and with which they occur in nature. The procedures dealing with the isolation of products from irradiated targets are arranged by target element.

  2. Solutions of Einstein's field equations

    Energy Technology Data Exchange (ETDEWEB)

    Tomonaga, Y [Utsunomiya Univ. (Japan). Faculty of Education

    1978-12-01

    In this paper the author investigates the Einstein's field equations of the non-vacuum case and generalizes the solution of Robertson-Walker by the three dimensional Einstein spaces. In Section 2 the author shortly generalizes the dynamic space-time of G. Lemetre and A. Friedmann by a simple transformation.

  3. Simulation of Simple Controlled Processes with Dead-Time.

    Science.gov (United States)

    Watson, Keith R.; And Others

    1985-01-01

    The determination of closed-loop response of processes containing dead-time is typically not covered in undergraduate process control, possibly because the solution by Laplace transforms requires the use of Pade approximation for dead-time, which makes the procedure lengthy and tedious. A computer-aided method is described which simplifies the…

  4. Determining serum bicarbonate; a simple syringe titrator and colorimeter.

    Science.gov (United States)

    BOONE, C W; FIELD, J B

    1953-12-01

    The use of a tuberculin syringe as a burette has made possible an easy bedside technique for the determination of serum bicarbonate. By combining it with the use of a simple colorimeter, a relatively untrained person can do numerous bicarbonate determinations with a high degree of accuracy. The same technique also lends itself to other colorimetric clinical procedures such as determination of gastric acidity.

  5. DETERMINING SERUM BICARBONATE—A Simple Syringe Titrator and Colorimeter

    Science.gov (United States)

    Boone, Charles W.; Field, John B.

    1953-01-01

    The use of a tuberculin syringe as a burette has made possible an easy bedside technique for the determination of serum bicarbonate. By combining it with the use of a simple colorimeter, a relatively untrained person can do numerous bicarbonate determinations with a high degree of accuracy. The same technique also lends itself to other colorimetric clinical procedures such as determination of gastric acidity. PMID:13106724

  6. Uniqueness of Solutions to Schrödinger Equations on Complex ...

    Indian Academy of Sciences (India)

    2006-09-05

    simple Lie groups. We show that if the initial data is a bi-invariant function that has sufficient decay and the solution has sufficient decay at another fixed value of time, then the solution has to be identically zero for all time.

  7. Modelling simple helically delivered dose distributions

    International Nuclear Information System (INIS)

    Fenwick, John D; Tome, Wolfgang A; Kissick, Michael W; Mackie, T Rock

    2005-01-01

    In a previous paper, we described quality assurance procedures for Hi-Art helical tomotherapy machines. Here, we develop further some ideas discussed briefly in that paper. Simple helically generated dose distributions are modelled, and relationships between these dose distributions and underlying characteristics of Hi-Art treatment systems are elucidated. In particular, we describe the dependence of dose levels along the central axis of a cylinder aligned coaxially with a Hi-Art machine on fan beam width, couch velocity and helical delivery lengths. The impact on these dose levels of angular variations in gantry speed or output per linear accelerator pulse is also explored

  8. General solution of linear vector supersymmetry

    International Nuclear Information System (INIS)

    Blasi, Alberto; Maggiore, Nicola

    2007-01-01

    We give the general solution of the Ward identity for the linear vector supersymmetry which characterizes all topological models. Such a solution, whose expression is quite compact and simple, greatly simplifies the study of theories displaying a supersymmetric algebraic structure, reducing to a few lines the proof of their possible finiteness. In particular, the cohomology technology, usually involved for the quantum extension of these theories, is completely bypassed. The case of Chern-Simons theory is taken as an example

  9. Determination of micro-quantities of several elements in soil solution by isotope dilution and activation analyses

    International Nuclear Information System (INIS)

    Cho, C.M.; Axmann, H.

    1965-01-01

    Determination of small quantities of plant nutrients in the soil solution of flooded rice soils is a difficult problem. The concentrations of Mn, Fe and P, for example, in some soil solutions are so small that no chemical method gives any accurate result. Neutron activation analysis was reported to give a much lower limit of detectability for several elements, while for elements with low-induced activity after neutron irradiation, substoichiometric isotopic dilution analysis was applied. One of the advantages of neutron activation analysis lies in the fact that simultaneous activation of every inducible element in a sample takes place. This gives an opportunity to determine many elements by one sample preparation and irradiation. This, however, is not a simple task since identification of the activated products and their quantitative estimation becomes very difficult. Certain operations of separation must be carried out before activity measurements. Ion-exchange resin columns and chemical separation following the addition of carriers were successfully used for the determination of many elements after neutron irradiation. These procedures, however, cannot be directly applied to the determination of the elements of agronomic interest. A procedure was developed to determine several elements of agronomic interest. Times of irradiation and cooling, quick separation by ion-exchange columns, together with chemical precipitation for β-emitters of relatively long half-lives, were all combined to get the maximum benefit from neutron activation analysis. For Fe, for which no satisfactory neutron activation analysis has yet been developed, a modified substoichiometric double isotope dilution procedure is applied

  10. Robotic simple prostatectomy: A consideration for large prostate adenomas

    Directory of Open Access Journals (Sweden)

    Joshua B. Nething

    2014-12-01

    Full Text Available Background: The management of benign prostatic hyperplasia (BPH has changed considerably over the last several decades. First line treatment of BPH and lower urinary tract symptoms (LUTS with medical therapy has created a population of men with much larger prostate glands, many of whom require surgical intervention. Patients with prostate glands greater than 80 to 100 grams may be better managed surgically with a retropubic prostatectomy. We explore our experience with robotic assisted simple prostatectomy and review the relevant literature. Database: The database reviewed includes our experience with seven patients undergoing robotic simple prostatectomy, and a comprehensive review of the previously published series of this procedure. In addition, the literature pertaining to a pure laparoscopic approach to simple prostatectomy is reviewed. Conclusion: Robotic experience and training has become a standard in resident training programs; while classic transurethral resection is being performed less for large prostate glands. The robotic approach to simple prostatectomy provides an excellent option for surgical treatment of very large prostate glands, providing patients acceptable results in terms of operative time, estimated blood loss, hospital stay and duration of Foley catheter.

  11. Simple renormalization group method for calculating geometrical and other equations of states

    International Nuclear Information System (INIS)

    Tsallis, C.; Schwaccheim, G.; Coniglio, A.

    1984-01-01

    A real space renormalization group procedure to calculate geometrical and thermal equations of states for the entire range of values of the external parameters is described. Its use is as simple as a Mean Field Approximation; however, it yields non trivial results and can be systematically improved. Such a procedure is illustrated by calculating, for all bond concentrations, the site mass density for the complete and the backbone percolating infinite clusters in square lattice: the results are quite satisfactory. (Author) [pt

  12. Singular perturbation of simple eigenvalues

    International Nuclear Information System (INIS)

    Greenlee, W.M.

    1976-01-01

    Two operator theoretic theorems which generalize those of asymptotic regular perturbation theory and which apply to singular perturbation problems are proved. Application of these theorems to concrete problems is involved, but the perturbation expansions for eigenvalues and eigenvectors are developed in terms of solutions of linear operator equations. The method of correctors, as well as traditional boundary layer techniques, can be used to apply these theorems. The current formulation should be applicable to highly singular ''hard core'' potential perturbations of the radial equation of quantum mechanics. The theorems are applied to a comparatively simple model problem whose analysis is basic to that of the quantum mechanical problem

  13. Analgesic techniques in minor painful procedures in neonatal units: a survey in northern Italy.

    Science.gov (United States)

    Codipietro, Luigi; Bailo, Elena; Nangeroni, Marco; Ponzone, Alberto; Grazia, Giuseppe

    2011-01-01

    The aim of this survey was to evaluate the current practice regarding pain assessment and pain management strategies adopted in commonly performed minor painful procedures in Northern Italian Neonatal Intensive Care Units (NICUs). A multicenter survey was conducted between 2008 and 2009 in 35 NICUs. The first part of the survey form covered pain assessment tools, the timing of analgesics, and the availability of written guidelines. A second section evaluated the analgesic strategies adopted in commonly performed painful procedures. The listed analgesic procedures were as follows: oral sweet solutions alone, non-nutritive sucking (NNS) alone, a combination of sweet solutions and NNS, breast-feeding where available, and topical anesthetics. Completed questionnaires were returned from 30 neonatal units (85.7% response rate). Ten of the 30 NICUs reported using pain assessment tools for minor invasive procedures. Neonatal Infant Pain Scale was the most frequently used pain scale (60%). Twenty neonatal units had written guidelines directing pain management practices. The most frequently used procedures were pacifiers alone (69%), followed by sweet-tasting solutions (58%). A 5% glucose solution was the most frequently utilized sweet-tasting solution (76.7%). A minority of NICUs (16.7%) administered 12% sucrose solutions for analgesia and the application of topical anesthetics was found in 27% of NICUs while breast-feeding was performed in 7% of NICUs. This study found a low adherence to national and international guidelines for analgesia in minor procedures: the underuse of neonatal pain scales (33%), sucrose solution administration before heel lance (23.3%), topical anesthetics before venipuncture, or other analgesic techniques. The presence of written pain control guidelines in these regions of Northern Italy increased in recent years (from 25% to 66%). © 2010 World Institute of Pain.

  14. 3D face reconstruction from 2D pictures: first results of a web-based computer aided system for aesthetic procedures.

    Science.gov (United States)

    Oliveira-Santos, Thiago; Baumberger, Christian; Constantinescu, Mihai; Olariu, Radu; Nolte, Lutz-Peter; Alaraibi, Salman; Reyes, Mauricio

    2013-05-01

    The human face is a vital component of our identity and many people undergo medical aesthetics procedures in order to achieve an ideal or desired look. However, communication between physician and patient is fundamental to understand the patient's wishes and to achieve the desired results. To date, most plastic surgeons rely on either "free hand" 2D drawings on picture printouts or computerized picture morphing. Alternatively, hardware dependent solutions allow facial shapes to be created and planned in 3D, but they are usually expensive or complex to handle. To offer a simple and hardware independent solution, we propose a web-based application that uses 3 standard 2D pictures to create a 3D representation of the patient's face on which facial aesthetic procedures such as filling, skin clearing or rejuvenation, and rhinoplasty are planned in 3D. The proposed application couples a set of well-established methods together in a novel manner to optimize 3D reconstructions for clinical use. Face reconstructions performed with the application were evaluated by two plastic surgeons and also compared to ground truth data. Results showed the application can provide accurate 3D face representations to be used in clinics (within an average of 2 mm error) in less than 5 min.

  15. A simple approach to recycle broiler litter as animal feed | Makinde ...

    African Journals Online (AJOL)

    Broiler litter (BL) is a major waste from poultry production that constitutes serious disposal and environmental pollution problems globally despite its potential as animal feed. Therefore, the objective of this study was to develop a simple procedure for converting broiler litter into animal feed using wheat offal (WO) and cattle ...

  16. Zeolites as alcohol adsorbents from aqueous solutions

    Directory of Open Access Journals (Sweden)

    Cekova Blagica

    2006-01-01

    Full Text Available The potential usage of zeolites as adsorbents for the removal of organic molecules from water was investigated in a series of experiments with aqueous solutions of lower alcohols. This could represent a simple solution to the problem of cleaning up industrial wastewater as well as recovering valuable chemicals at relatively low costs. Adsorption isotherms of the Langmuir type were applied, and calculations showed that the amount of propanol adsorbed on silicalite corresponded to approximately 70% of the pore volume. The adsorption process is simple, and recovery of the more concentrated products is easily done by heat treatment and/or at lowered pressures. Adsorption experiments with aqueous acetone showed that silicalite had approximately the same adsorption capacity for acetone as for n-propanol. Heats of adsorption were determined calorimetrically.

  17. A simple two-step purification procedure for the iC3b binding collectin conglutinin

    DEFF Research Database (Denmark)

    Krogh-Meibom, Thomas; Ingvartsen, Klaus Lønne; Tornoe, Ida

    2010-01-01

    Bovine conglutinin is a serum protein involved in innate immunity. It binds calcium dependently to iC3b, a product of the complement component C3 deposited on cell surfaces, immune complexes or artificial surfaces after complement activation. We here present a simple and efficient two-step proced...

  18. A Simple Technique for Shoulder Arthrography

    Energy Technology Data Exchange (ETDEWEB)

    Berna-Serna, J.D.; Redondo, M.V.; Martinez, F.; Reus, M.; Alonso, J.; Parrilla, A.; Campos, P.A. [Virgen de la Arrixaca Univ. Hospital, El Palmar, Murcia (Spain). Dept. of Radiology

    2006-09-15

    Purpose: To present a systematic approach to teaching a technique for arthrography of the shoulder. Using an adhesive marker-plate with radiopaque coordinates, precise sites for puncture can be identified and the need for fluoroscopic guidance obviated. Material and Methods: Forty-six glenohumeral arthrograms were performed in 45 patients; in 1 case involving examination of both shoulders. The stages of the technique are described in detail, as are the fundamental aspects of achieving an effective glenohumeral injection. Pain intensity was measured in all patients using a verbal description scale. Results: Shoulder arthrography was successful in all cases. Average time taken for the procedure was 7 min, with no difference in the respective times required by an experienced radiologist and a resident. The procedure was well tolerated by most patients, with slight discomfort being observed in a very few cases. Conclusion: The arthrographic technique used in this study is simple, safe, rapid, and reproducible, and has the advantage of precise localization of the site for puncture without need for fluoroscopic guidance. The procedure described in this study can be of help in teaching residents and can reduce the learning curve for radiologists with no experience in arthrographic methods. It also reduces the time of exposure to fluoroscopy Keywords: Arthrography, joint, shoulder.

  19. Attractor mechanism as a distillation procedure

    International Nuclear Information System (INIS)

    Levay, Peter; Szalay, Szilard

    2010-01-01

    In a recent paper it was shown that for double extremal static spherical symmetric BPS black hole solutions in the STU model the well-known process of moduli stabilization at the horizon can be recast in a form of a distillation procedure of a three-qubit entangled state of a Greenberger-Horne-Zeilinger type. By studying the full flow in moduli space in this paper we investigate this distillation procedure in more detail. We introduce a three-qubit state with amplitudes depending on the conserved charges, the warp factor, and the moduli. We show that for the recently discovered non-BPS solutions it is possible to see how the distillation procedure unfolds itself as we approach the horizon. For the non-BPS seed solutions at the asymptotically Minkowski region we are starting with a three-qubit state having seven nonequal nonvanishing amplitudes and finally at the horizon we get a Greenberger-Horne-Zeilinger state with merely four nonvanishing ones with equal magnitudes. The magnitude of the surviving nonvanishing amplitudes is proportional to the macroscopic black hole entropy. A systematic study of such attractor states shows that their properties reflect the structure of the fake superpotential. We also demonstrate that when starting with the very special values for the moduli corresponding to flat directions the uniform structure at the horizon deteriorates due to errors generalizing the usual bit flips acting on the qubits of the attractor states.

  20. 46 CFR 153.1035 - Acetone cyanohydrin or lactonitrile solutions.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 5 2010-10-01 2010-10-01 false Acetone cyanohydrin or lactonitrile solutions. 153.1035... Special Cargo Procedures § 153.1035 Acetone cyanohydrin or lactonitrile solutions. No person may operate a tankship carrying a cargo of acetone cyanohydrin or lactonitrile solutions, unless that cargo is stabilized...

  1. Visible and UV photo-detection in ZnO nanostructured thin films via simple tuning of solution method.

    Science.gov (United States)

    Khokhra, Richa; Bharti, Bandna; Lee, Heung-No; Kumar, Rajesh

    2017-11-08

    This study demonstrates significant visible light photo-detection capability of pristine ZnO nanostructure thin films possessing substantially high percentage of oxygen vacancies [Formula: see text] and zinc interstitials [Formula: see text], introduced by simple tuning of economical solution method. The demonstrated visible light photo-detection capability, in addition to the inherent UV light detection ability of ZnO, shows great dependency of [Formula: see text] and [Formula: see text] with the nanostructure morphology. The dependency was evaluated by analyzing the presence/percentage of [Formula: see text] and [Formula: see text] using photoluminescence (PL) and X-ray photoelectron spectroscopy (XPS) measurements. Morphologies of ZnO viz. nanoparticles (NPs), nanosheets (NSs) and nanoflowers (NFs), as a result of tuning of synthesis method contended different concentrations of defects, demonstrated different photo-detection capabilities in the form of a thin film photodetector. The photo-detection capability was investigated under different light excitations (UV; 380~420 nm, white ; λ > 420 nm and green; 490~570 nm). The as fabricated NSs photodetector possessing comparatively intermediate percentage of [Formula: see text] ~ 47.7% and [Formula: see text] ~ 13.8% exhibited superior performance than that of NPs and NFs photodetectors, and ever reported photodetectors fabricated by using pristine ZnO nanostructures in thin film architecture. The adopted low cost and simplest approach makes the pristine ZnO-NSs applicable for wide-wavelength applications in optoelectronic devices.

  2. MITG test procedure and results

    International Nuclear Information System (INIS)

    Eck, M.E.; Mukunda, M.

    1983-01-01

    Elements and modules for Radioisotope Thermoelectric Generator have been performance tested since the inception of the RTG program. These test articles seldom resembled flight hardware and often lacked adequate diagnostic instrumentation. Because of this, performance problems were not identified in the early stage of program development. The lack of test data in an unexpected area often hampered the development of a problem solution. A procedure for conducting the MITG Test was developed in an effort to obtain data in a systematic, unambiguous manner. This procedure required the development of extensive data acquisition software and test automation. The development of a facility to implement the test procedure, the facility hardware and software requirements, and the results of the MITG testing are the subject of this paper

  3. Optimal Power Flow in Islanded Microgrids Using a Simple Distributed Algorithm

    DEFF Research Database (Denmark)

    Sanseverino, Eleonora Riva; Di Silvestre, Maria Luisa; Badalamenti, Romina

    2015-01-01

    In this paper, the problem of distributed power losses minimization in islanded distribution systems is dealt with. The problem is formulated in a very simple manner and a solution is reached after a few iterations. The considered distribution system, a microgrid, will not need large bandwidth co...

  4. Explicit solutions of Fisher's equation with three zeros

    Directory of Open Access Journals (Sweden)

    M. F. K. Abur-Robb

    1990-01-01

    Full Text Available Explicit traveling wave solutions of Fisher's equation with three simple zeros ut=uxx+u(1−u(u−a, a∈(0,1, are obtained for the wave speeds C=±2(12−a suggested by pure analytic considerations. Two types of solutions are obtained: one type is of a permanent wave form whereas the other is not.

  5. Effectiveness of the implementation of a simple radiation reduction protocol in the catheterization laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Jurado-Román, Alfonso, E-mail: alfonsojuradoroman@gmail.com [Unidad de Hemodinámica, Servicio de Cardiología, Hospital General Universitario de Ciudad Real (Spain); Sánchez-Pérez, Ignacio; Lozano Ruíz-Poveda, Fernando; López-Lluva, María T.; Pinilla-Echeverri, Natalia; Moreno Arciniegas, Andrea [Unidad de Hemodinámica, Servicio de Cardiología, Hospital General Universitario de Ciudad Real (Spain); Agudo-Quilez, Pilar [Servicio de Cardiología, Hospital Universitario de La Princesa, Madrid (Spain); Gil Agudo, Antonio [Servicio de Radiofísica y Protección Radiológica, Hospital General Universitario de Ciudad Real (Spain)

    2016-07-15

    Background and purpose: A reduction in radiation doses at the catheterization laboratory, maintaining the quality of procedures is essential. Our objective was to analyze the results of a simple radiation reduction protocol at a high-volume interventional cardiology unit. Methods: We analyzed 1160 consecutive procedures: 580 performed before the implementation of the protocol and 580 after it. The protocol consisted in: the reduction of the number of ventriculographies and aortographies, the optimization of the collimation and the geometry of the X ray tube-patient-receptor, the use of low dose-rate fluoroscopy and the reduction of the number of cine sequences using the software “last fluoroscopy hold”. Results: There were no significant differences in clinical baseline features or in the procedural characteristics with the exception of a higher percentage of radial approach (30.7% vs 69.6%; p < 0.001) and of percutaneous coronary interventions of chronic total occlusions after the implementation of the protocol (2.1% vs 6.7%; p = 0,001). Angiographic success was similar during both periods (98.3% vs 99.2%; p = 0.2). There were no significant differences between both periods regarding the overall duration of the procedures (26.9 vs 29.6 min; p = 0.14), or the fluoroscopy time (13.3 vs 13.2 min; p = 0.8). We observed a reduction in the percentage of procedures with ventriculography (80.9% vs 7.1%; p < 0.0001) or aortography (15.4% vs 4.4%; p < 0.0001), the cine runs (21.8 vs 6.9; p < 0.0001) and the dose–area product (165 vs 71 Gyxcm{sup 2}; p < 0.0001). Conclusions: With the implementation of a simple radiation reduction protocol, a 57% reduction of dose–area product was observed without a reduction in the quality or the complexity of procedures. - Highlights: • This simple protocol can achieve a reduction in dose–area product of 57%. • It does not interfere with the quality or complexity of the procedures. • Full advantage of “Last Fluoroscopy

  6. A singular one-parameter family of solutions in cubic superstring field theory

    Energy Technology Data Exchange (ETDEWEB)

    Arroyo, E. Aldo [Centro de Ciências Naturais e Humanas, Universidade Federal do ABC, Santo André, 09210-170 São Paulo, SP (Brazil)

    2016-05-03

    Performing a gauge transformation of a simple identity-like solution of superstring field theory, we construct a one-parameter family of solutions, and by evaluating the energy associated to this family, we show that for most of the values of the parameter the solution represents the tachyon vacuum, except for two isolated singular points where the solution becomes the perturbative vacuum and the half brane solution.

  7. On centralized power pool auction: a novel multipliers stabilization procedure

    International Nuclear Information System (INIS)

    Jimenez-Redondo, Noemi

    2005-01-01

    This paper addresses the Short-Term Hydro-Thermal Coordination (STHTC) problem. It is a large-scale, combinatorial and nonlinear optimization problem. It is usually solved using a Lagrangian Relaxation (LR) approach. LR procedure is based on the solution of the dual problem of the original one. The dual problem variables are the Lagrange multipliers. These multipliers have an economic meaning: electric energy hourly prices. This paper focuses on an efficient solution of the dual problem of the STHTC problem. A novel multiplier stabilization technique, which significantly improves the quality of the solution, is presented. The provided method could be the optimization tool used by the Independent System Operator of a centralized Power Pool. The solution procedure diminishes the conflict of interest in determining energy prices. A realistic large-scale case study illustrates the behavior of the presented approach. (Author)

  8. Complex solutions for generalised fitzhughnagumo equation

    International Nuclear Information System (INIS)

    Neirameh, A.

    2014-01-01

    During present investigation, a direct algebraic method on complex solutions of nonlinear partial differential equation is developed and tested in the case of generalized Burgers-Huxley equation. The proposed scheme can be used in a wide class of nonlinear reaction-diffusion equations. These calculations demonstrate that the accuracy of the direct algebraic solutions is quite high even in the case of a small number of grid points. This method is a very reliable, simple, small computation costs, flexible, and convenient alternative method. (author)

  9. Direct Georeferencing of Uav Data Based on Simple Building Structures

    Science.gov (United States)

    Tampubolon, W.; Reinhardt, W.

    2016-06-01

    Unmanned Aerial Vehicle (UAV) data acquisition is more flexible compared with the more complex traditional airborne data acquisition. This advantage puts UAV platforms in a position as an alternative acquisition method in many applications including Large Scale Topographical Mapping (LSTM). LSTM, i.e. larger or equal than 1:10.000 map scale, is one of a number of prominent priority tasks to be solved in an accelerated way especially in third world developing countries such as Indonesia. As one component of fundamental geospatial data sets, large scale topographical maps are mandatory in order to enable detailed spatial planning. However, the accuracy of the products derived from the UAV data are normally not sufficient for LSTM as it needs robust georeferencing, which requires additional costly efforts such as the incorporation of sophisticated GPS Inertial Navigation System (INS) or Inertial Measurement Unit (IMU) on the platform and/or Ground Control Point (GCP) data on the ground. To reduce the costs and the weight on the UAV alternative solutions have to be found. This paper outlines a direct georeferencing method of UAV data by providing image orientation parameters derived from simple building structures and presents results of an investigation on the achievable results in a LSTM application. In this case, the image orientation determination has been performed through sequential images without any input from INS/IMU equipment. The simple building structures play a significant role in such a way that geometrical characteristics have been considered. Some instances are the orthogonality of the building's wall/rooftop and the local knowledge of the building orientation in the field. In addition, we want to include the Structure from Motion (SfM) approach in order to reduce the number of required GCPs especially for the absolute orientation purpose. The SfM technique applied to the UAV data and simple building structures additionally presents an effective tool

  10. DIRECT GEOREFERENCING OF UAV DATA BASED ON SIMPLE BUILDING STRUCTURES

    Directory of Open Access Journals (Sweden)

    W. Tampubolon

    2016-06-01

    Full Text Available Unmanned Aerial Vehicle (UAV data acquisition is more flexible compared with the more complex traditional airborne data acquisition. This advantage puts UAV platforms in a position as an alternative acquisition method in many applications including Large Scale Topographical Mapping (LSTM. LSTM, i.e. larger or equal than 1:10.000 map scale, is one of a number of prominent priority tasks to be solved in an accelerated way especially in third world developing countries such as Indonesia. As one component of fundamental geospatial data sets, large scale topographical maps are mandatory in order to enable detailed spatial planning. However, the accuracy of the products derived from the UAV data are normally not sufficient for LSTM as it needs robust georeferencing, which requires additional costly efforts such as the incorporation of sophisticated GPS Inertial Navigation System (INS or Inertial Measurement Unit (IMU on the platform and/or Ground Control Point (GCP data on the ground. To reduce the costs and the weight on the UAV alternative solutions have to be found. This paper outlines a direct georeferencing method of UAV data by providing image orientation parameters derived from simple building structures and presents results of an investigation on the achievable results in a LSTM application. In this case, the image orientation determination has been performed through sequential images without any input from INS/IMU equipment. The simple building structures play a significant role in such a way that geometrical characteristics have been considered. Some instances are the orthogonality of the building’s wall/rooftop and the local knowledge of the building orientation in the field. In addition, we want to include the Structure from Motion (SfM approach in order to reduce the number of required GCPs especially for the absolute orientation purpose. The SfM technique applied to the UAV data and simple building structures additionally presents an

  11. A Simple Approach to Interest-Rate Option Pricing.

    OpenAIRE

    Turnbull, Stuart M; Milne, Frank

    1991-01-01

    A simple introduction to contingent claim valuation of risky assets in a discrete time, stochastic interest-rate economy is provided. Taking the term structure of interest rates as exogenous, closed-form solutions are derived for European options written on (1) Treasury bills, (2) interest-rate forward contracts, (3) interest-rate futures contracts, (4) Treasury bonds, (5) interest-rate caps, (6) stock options, (7) equity forward contracts, (8) equity futures contracts, (9) Eurodollar liabili...

  12. Ion exchange removal of technetium from salt solutions

    International Nuclear Information System (INIS)

    Walker, D.D.

    1983-01-01

    Ion exchange methods for removing technetium from waste salt solutions have been investigated by the Savannah River Laboratory (SRL). These experiments have shown: Commercially available anion exchange resins show high selectivity and capacity for technetium. In column runs, 150 column volumes of salt solution were passed through an ion exchange column before 50% 99 Tc breakthrough was reached. The technetium can be eluted from the resin with nitric acid. Reducing resins (containing borohydride) work well in simple hydroxide solutions, but not in simulated salt solutions. A mercarbide resin showed a very high selectivity for Tc, but did not work well in column operation

  13. A simple agar plate preparation for effective transfer of Ureaplasma colonies onto nitrocellulose membranes for colony immunoblotting.

    Science.gov (United States)

    Zimmerman, Carl-Ulrich R; Stiedl, Thomas; Spergser, Joachim; Rosengarten, Renate

    2014-09-01

    A simple method for preparing agar plates is presented, which allows an efficient transfer of Ureaplasma colonies to nitrocellulose membranes for subsequent immunological detection. This simple and reproducible procedure was used to demonstrate antigenic variation in the phase-variable mba-locus of Ureaplasma parvum serovar 3. Copyright © 2014 Elsevier B.V. All rights reserved.

  14. New methods For Modeling Transport Of Water And Solutes In Soils

    DEFF Research Database (Denmark)

    Møldrup, Per

    Recent models for water and solute transport in unsaturated soils have been mechanistically based but numerically very involved. This dissertation concerns the development of mechanistically-based but numerically simple models for calculating and analyzing transport of water and solutes in soil...

  15. A new and simple gravimetric method for determination of uranium

    International Nuclear Information System (INIS)

    Saxena, A.K.

    1994-01-01

    A new and simple gravimetric method for determining uranium has been described. Using a known quantity of uranyl nitrate as the test solution, an alcoholic solution of 2-amino-2-methyl 1:3 propanediol (AMP) was added slowly. A yellow precipitate was obtained which was filtered through ashless filter paper, washed with alcohol, dried and ignited at 800 degC for 4h. It gave a black powder as a product which was shown by X-ray diffraction to be U 3 O 8 . The percentage error was found in the range -0.09 to +0.89. (author). 8 refs., 1 tab

  16. An Integrated Solution-Based Rapid Sample Preparation Procedure for the Analysis of N-Glycans From Therapeutic Monoclonal Antibodies.

    Science.gov (United States)

    Aich, Udayanath; Liu, Aston; Lakbub, Jude; Mozdzanowski, Jacek; Byrne, Michael; Shah, Nilesh; Galosy, Sybille; Patel, Pramthesh; Bam, Narendra

    2016-03-01

    Consistent glycosylation in therapeutic monoclonal antibodies is a major concern in the biopharmaceutical industry as it impacts the drug's safety and efficacy and manufacturing processes. Large numbers of samples are created for the analysis of glycans during various stages of recombinant proteins drug development. Profiling and quantifying protein N-glycosylation is important but extremely challenging due to its microheterogeneity and more importantly the limitations of existing time-consuming sample preparation methods. Thus, a quantitative method with fast sample preparation is crucial for understanding, controlling, and modifying the glycoform variance in therapeutic monoclonal antibody development. Presented here is a rapid and highly quantitative method for the analysis of N-glycans from monoclonal antibodies. The method comprises a simple and fast solution-based sample preparation method that uses nontoxic reducing reagents for direct labeling of N-glycans. The complete work flow for the preparation of fluorescently labeled N-glycans takes a total of 3 h with less than 30 min needed for the release of N-glycans from monoclonal antibody samples. Copyright © 2016 American Pharmacists Association®. Published by Elsevier Inc. All rights reserved.

  17. The concept and method of closed reduction and internal fixation: a new approach for the treatment of simple zygoma fractures.

    Science.gov (United States)

    Uda, Hirokazu; Kamochi, Hideaki; Sugawara, Yasushi; Sarukawa, Syunji; Sunaga, Ataru

    2013-11-01

    The authors have developed a new minimally invasive surgical procedure for simple zygoma fractures, a closed reduction and internal fixation method, that uses a cannulated cortical screw system. From 2007 to 2012, 42 selected patients with simple zygoma fractures without ocular problems or shear at the zygomatic frontal portion were treated with this method. The mean age of the patients was 33 years (range, 13 to 77 years). The authors achieved good repositioning, equivalent to results achieved with conventional procedures in all cases. No notable complication occurred except for minor infection in two cases. Mean operative time was 32 minutes (range, 19 to 58 minutes). Postoperative relapse was found only in the posterior direction (poperative time, less effect on soft tissue, maintenance of bone healing potential, and decreased postoperative pain and swelling. The authors concluded that this method has the potential to become a future surgical procedure for simple zygoma fractures. Therapeutic, IV.

  18. Simple machines

    CERN Document Server

    Graybill, George

    2007-01-01

    Just how simple are simple machines? With our ready-to-use resource, they are simple to teach and easy to learn! Chocked full of information and activities, we begin with a look at force, motion and work, and examples of simple machines in daily life are given. With this background, we move on to different kinds of simple machines including: Levers, Inclined Planes, Wedges, Screws, Pulleys, and Wheels and Axles. An exploration of some compound machines follows, such as the can opener. Our resource is a real time-saver as all the reading passages, student activities are provided. Presented in s

  19. A design procedure for the phase-controlled parallel-loaded resonant inverter

    Science.gov (United States)

    King, Roger J.

    1989-01-01

    High-frequency-link power conversion and distribution based on a resonant inverter (RI) has been recently proposed. The design of several topologies is reviewed, and a simple approximate design procedure is developed for the phase-controlled parallel-loaded RI. This design procedure seeks to ensure the benefits of resonant conversion and is verified by data from a laboratory 2.5 kVA, 20-kHz converter. A simple phasor analysis is introduced as a useful approximation for design purposes. The load is considered to be a linear impedance (or an ac current sink). The design procedure is verified using a 2.5-kVA 20-kHz RI. Also obtained are predictable worst-case ratings for each component of the resonant tank circuit and the inverter switches. For a given load VA requirement, below-resonance operation is found to result in a significantly lower tank VA requirement. Under transient conditions such as load short-circuit, a reversal of the expected commutation sequence is possible.

  20. The generation of simple compliance boundaries for mobile communication base station antennas using formulae for SAR estimation.

    Science.gov (United States)

    Thors, B; Hansson, B; Törnevik, C

    2009-07-07

    In this paper, a procedure is proposed for generating simple and practical compliance boundaries for mobile communication base station antennas. The procedure is based on a set of formulae for estimating the specific absorption rate (SAR) in certain directions around a class of common base station antennas. The formulae, given for both whole-body and localized SAR, require as input the frequency, the transmitted power and knowledge of antenna-related parameters such as dimensions, directivity and half-power beamwidths. With knowledge of the SAR in three key directions it is demonstrated how simple and practical compliance boundaries can be generated outside of which the exposure levels do not exceed certain limit values. The conservativeness of the proposed procedure is discussed based on results from numerical radio frequency (RF) exposure simulations with human body phantoms from the recently developed Virtual Family.

  1. An Efficient, Simple, and Noninvasive Procedure for Genotyping Aquatic and Nonaquatic Laboratory Animals.

    Science.gov (United States)

    Okada, Morihiro; Miller, Thomas C; Roediger, Julia; Shi, Yun-Bo; Schech, Joseph Mat

    2017-09-01

    Various animal models are indispensible in biomedical research. Increasing awareness and regulations have prompted the adaptation of more humane approaches in the use of laboratory animals. With the development of easier and faster methodologies to generate genetically altered animals, convenient and humane methods to genotype these animals are important for research involving such animals. Here, we report skin swabbing as a simple and noninvasive method for extracting genomic DNA from mice and frogs for genotyping. We show that this method is highly reliable and suitable for both immature and adult animals. Our approach allows a simpler and more humane approach for genotyping vertebrate animals.

  2. Sigmoid colon volvulus immediately after ultrasound-guided simple ovarian cyst aspiration: a case report

    Directory of Open Access Journals (Sweden)

    Firas Al-Rshoud

    2017-03-01

    Conclusion: Clinicians should bear in mind such complication(Sigmoid volvulus while draining a pelvic cyst as this procedure is adapted by some clinician as it is less invasive than surgical management of persistent simple ovarian cyst.

  3. The functional variable method for finding exact solutions of some ...

    Indian Academy of Sciences (India)

    Abstract. In this paper, we implemented the functional variable method and the modified. Riemann–Liouville derivative for the exact solitary wave solutions and periodic wave solutions of the time-fractional Klein–Gordon equation, and the time-fractional Hirota–Satsuma coupled. KdV system. This method is extremely simple ...

  4. Solution of the mathematical adjoint equations for an interface current nodal formulation

    International Nuclear Information System (INIS)

    Yang, W.S.; Taiwo, T.A.; Khalil, H.

    1994-01-01

    Two techniques for solving the mathematical adjoint equations of an interface current nodal method are described. These techniques are the ''similarity transformation'' procedure and a direct solution scheme. A theoretical basis is provided for the similarity transformation procedure originally proposed by Lawrence. It is shown that the matrices associated with the mathematical and physical adjoint equations are similar to each other for the flat transverse leakage approximation but not for the quadratic leakage approximation. It is also shown that a good approximate solution of the mathematical adjoint for the quadratic transverse leakage approximation is obtained by applying the similarity transformation for the flat transverse leakage approximation to the physical adjoint solution. The direct solution scheme, which was developed as an alternative to the similarity transformation procedure, yields the correct mathematical adjoint solution for both flat and quadratic transverse leakage approximations. In this scheme, adjoint nodal equations are cast in a form very similar to that of the forward equations by employing a linear transformation of the adjoint partial currents. This enables the use of the forward solution algorithm with only minor modifications for solving the mathematical adjoint equations. By using the direct solution scheme as a reference method, it is shown that while the results computed with the similarity transformation procedure are approximate, they are sufficiently accurate for calculations of global and local reactivity changes resulting from coolant voiding in a liquid-metal reactor

  5. Adiabatic pumping solutions in global AdS

    Energy Technology Data Exchange (ETDEWEB)

    Carracedo, Pablo [Meteo-Galicia,Santiago de Compostela E-15782 (Spain); Mas, Javier; Musso, Daniele; Serantes, Alexandre [Departamento de Física de Partículas, Universidade de Santiago de Compostela,Santiago de Compostela E-15782 (Spain); Instituto Galego de Física de Altas Enerxías (IGFAE),Santiago de Compostela E-15782 (Spain)

    2017-05-26

    We construct a family of very simple stationary solutions to gravity coupled to a massless scalar field in global AdS. They involve a constantly rising source for the scalar field at the boundary and thereby we name them pumping solutions. We construct them numerically in D=4. They are regular and, generically, have negative mass. We perform a study of linear and nonlinear stability and find both stable and unstable branches. In the latter case, solutions belonging to different sub-branches can either decay to black holes or to limiting cycles. This observation motivates the search for non-stationary exactly time-periodic solutions which we actually construct. We clarify the role of pumping solutions in the context of quasistatic adiabatic quenches. In D=3 the pumping solutions can be related to other previously known solutions, like magnetic or translationally-breaking backgrounds. From this we derive an analytic expression.

  6. Radiation induced homogeneous precipitation in undersaturated solid-solutions

    International Nuclear Information System (INIS)

    Cauvin, Richard; Martin, Georges.

    1978-01-01

    The stability of various types of solid solutions under irradiation is studied. In this paper, observations made on AlZn solid solutions under 1 MeV electron irradiation are reported. Al-Zn was chosen as a prototype of solid solutions with a simple miscibility gap. It is shown that under appropriate irradiation conditions undersaturated AnZn solid solutions give rise to a homogeneous precipitation of coherent G.P. zones and of incoherent Zn precipitates the atomic volume of which is smaller than that of the matrix. We propose a more general treatment of solute concentration heterogeneities in solid solutions under irradiation and suggest how it might account for the nucleation of the observed phases. The growth of the observed precipitates is studied

  7. Application of thermodynamics to silicate crystalline solutions

    Science.gov (United States)

    Saxena, S. K.

    1972-01-01

    A review of thermodynamic relations is presented, describing Guggenheim's regular solution models, the simple mixture, the zeroth approximation, and the quasi-chemical model. The possibilities of retrieving useful thermodynamic quantities from phase equilibrium studies are discussed. Such quantities include the activity-composition relations and the free energy of mixing in crystalline solutions. Theory and results of the study of partitioning of elements in coexisting minerals are briefly reviewed. A thermodynamic study of the intercrystalline and intracrystalline ion exchange relations gives useful information on the thermodynamic behavior of the crystalline solutions involved. Such information is necessary for the solution of most petrogenic problems and for geothermometry. Thermodynamic quantities for tungstates (CaWO4-SrWO4) are calculated.

  8. Fully implicit, coupled procedures in computational fluid dynamics an engineer's resource book

    CERN Document Server

    Mazhar, Zeka

    2016-01-01

    This book introduces a new generation of superfast algorithms for the treatment of the notoriously difficult velocity-pressure coupling problem in incompressible fluid flow solutions. It provides all the necessary details for the understanding and implementation of the procedures. The derivation and construction of the fully-implicit, block-coupled, incomplete decomposition mechanism are given in a systematic, but easy fashion. Worked-out solutions are included, with comparisons and discussions. A complete program code is included for faster implementation of the algorithm. A brief literature review of the development of the classical solution procedures is included as well. .

  9. Development of a simple extraction procedure for chlorpyrifos determination in food samples by immunoassay.

    Science.gov (United States)

    Gabaldón, J A; Maquieira, A; Puchades, R

    2007-02-28

    The suitability of immunoassay methodology for rapid and accurate determination of chlorpyrifos in vegetables was tested. The optimised ELISA detection limit was 0.32ng/ml, with a working range from 0.69 to 6.21ng/ml and an immunoassay test-mid point (IC(50)) of 2.08ng/ml. A rapid sample preparation procedure considering different parameters such as the amount of sample, volume of extractant, extraction time and dilution factor was optimised. The developed direct extraction (DE) and multiresidue (ME) standard procedures were performed in different fortified fresh and processed vegetable samples (tomato, bonnet pepper, bean, pea, asparagus, broccoli, watermelon, melon, lettuce, cucumber, celery and red pepper). Recoveries were in all cases in the whole range 85.2-108.9% for both DE and ME extracts. Also, the comparison of the results obtained by both immunochemical and chromatographic methods for spiked fruits and vegetables were good with a correlation coefficient (r) of 0.97.

  10. Periodic solutions of dissipative systems revisited

    Directory of Open Access Journals (Sweden)

    Górniewicz Lech

    2006-01-01

    Full Text Available We reprove in an extremely simple way the classical theorem that time periodic dissipative systems imply the existence of harmonic periodic solutions, in the case of uniqueness. We will also show that, in the lack of uniqueness, the existence of harmonics is implied by uniform dissipativity. The localization of starting points and multiplicity of periodic solutions will be established, under suitable additional assumptions, as well. The arguments are based on the application of various asymptotic fixed point theorems of the Lefschetz and Nielsen type.

  11. Periodic solutions of dissipative systems revisited

    Directory of Open Access Journals (Sweden)

    Lech Górniewicz

    2006-05-01

    Full Text Available We reprove in an extremely simple way the classical theorem that time periodic dissipative systems imply the existence of harmonic periodic solutions, in the case of uniqueness. We will also show that, in the lack of uniqueness, the existence of harmonics is implied by uniform dissipativity. The localization of starting points and multiplicity of periodic solutions will be established, under suitable additional assumptions, as well. The arguments are based on the application of various asymptotic fixed point theorems of the Lefschetz and Nielsen type.

  12. Study of liquids and solutions

    International Nuclear Information System (INIS)

    Bellissent-Funel, M.C.

    1994-01-01

    A critical review of what has been achieved on the structure of liquids and solutions and the capabilities and developments of neutron scattering in this domain, are presented. A great variety of simple to complex systems has been investigated with the aim of obtaining a full microscopic description of the structure. Selected examples demonstrate the neutron scattering determination of interaction potentials, intermolecular structures and partial structure factors of complex systems. The isotopic substitution method is illustrated by the application to the study of the solvation of ions in aqueous and non aqueous solutions. (author). 9 figs., 32 refs

  13. Qualitative Observations Concerning Packing Densities for Liquids, Solutions, and Random Assemblies of Spheres

    Science.gov (United States)

    Duer, W. C.; And Others

    1977-01-01

    Discusses comparisons of packing densities derived from known molar volume data of liquids and solutions. Suggests further studies for using assemblies of spheres as models for simple liquids and solutions. (MLH)

  14. Double-resolution electron holography with simple Fourier transform of fringe-shifted holograms.

    Science.gov (United States)

    Volkov, V V; Han, M G; Zhu, Y

    2013-11-01

    We propose a fringe-shifting holographic method with an appropriate image wave recovery algorithm leading to exact solution of holographic equations. With this new method the complex object image wave recovered from holograms appears to have much less traditional artifacts caused by the autocorrelation band present practically in all Fourier transformed holograms. The new analytical solutions make possible a double-resolution electron holography free from autocorrelation band artifacts and thus push the limits for phase resolution. The new image wave recovery algorithm uses a popular Fourier solution of the side band-pass filter technique, while the fringe-shifting holographic method is simple to implement in practice. Published by Elsevier B.V.

  15. A Simple K-Map Based Variable Selection Scheme in the Direct ...

    African Journals Online (AJOL)

    A multiplexer with (n-l) data select inputs can realise directly a function of n variables. In this paper, a simple k-map based variable selection scheme is proposed such that an n variable logic function can be synthesised using a multiplexer with (n-q) data input variables and q data select variables. The procedure is based on ...

  16. Brane solutions sourced by a scalar with vanishing potential and classification of scalar branes

    Energy Technology Data Exchange (ETDEWEB)

    Cadoni, Mariano [Dipartimento di Fisica, Università di Cagliari,Cittadella Universitaria, 09042 Monserrato (Italy); INFN, Sezione di Cagliari,Cagliari (Italy); Franzin, Edgardo [Dipartimento di Fisica, Università di Cagliari,Cittadella Universitaria, 09042 Monserrato (Italy); INFN, Sezione di Cagliari,Cagliari (Italy); CENTRA, Departamento de Física, Instituto Superior Técnico, Universidade de Lisboa,Avenida Rovisco Pais 1, 1049 Lisboa (Portugal); Serra, Matteo [Dipartimento di Matematica, Sapienza Università di Roma,Piazzale Aldo Moro 2, 00185 Roma (Italy)

    2016-01-20

    We derive exact brane solutions of minimally coupled Einstein-Maxwell-scalar gravity in d+2 dimensions with a vanishing scalar potential and we show that these solutions are conformal to the Lifshitz spacetime whose dual QFT is characterized by hyperscaling violation. These solutions, together with the AdS brane and the domain wall sourced by an exponential potential, give the complete list of scalar branes sourced by a generic potential having simple (scale-covariant) scaling symmetries not involving Galilean boosts. This allows us to give a classification of both simple and interpolating brane solution of minimally coupled Einstein-Maxwell-scalar gravity having no Schrödinger isometries, which may be very useful for holographic applications.

  17. A simple method to determine evaporation and compensate for liquid losses in small-scale cell culture systems.

    Science.gov (United States)

    Wiegmann, Vincent; Martinez, Cristina Bernal; Baganz, Frank

    2018-04-24

    Establish a method to indirectly measure evaporation in microwell-based cell culture systems and show that the proposed method allows compensating for liquid losses in fed-batch processes. A correlation between evaporation and the concentration of Na + was found (R 2  = 0.95) when using the 24-well-based miniature bioreactor system (micro-Matrix) for a batch culture with GS-CHO. Based on these results, a method was developed to counteract evaporation with periodic water additions based on measurements of the Na + concentration. Implementation of this method resulted in a reduction of the relative liquid loss after 15 days of a fed-batch cultivation from 36.7 ± 6.7% without volume corrections to 6.9 ± 6.5% with volume corrections. A procedure was established to indirectly measure evaporation through a correlation with the level of Na + ions in solution and deriving a simple formula to account for liquid losses.

  18. A Simple Suturing Technique for Laparoscopic Ligation of Vascular Pedicles

    Directory of Open Access Journals (Sweden)

    Keith A. Aqua

    1996-01-01

    Full Text Available We report on the performance of 348 adnexectomies and 35 uterine artery ligations for both benign and malignant disease using a simple laparoscopic suturing technique. Only 5-mm ports are required, and there was no morbidity directly associated with this approach. The procedure can be performed quickly, is relatively inexpensive, and allows hysterectomy and oophorectomy to be performed without bipolar electrocautery.

  19. Analytical Solution of Multicompartment Solute Kinetics for Hemodialysis

    Directory of Open Access Journals (Sweden)

    Przemysław Korohoda

    2013-01-01

    Full Text Available Objective. To provide an exact solution for variable-volume multicompartment kinetic models with linear volume change, and to apply this solution to a 4-compartment diffusion-adjusted regional blood flow model for both urea and creatinine kinetics in hemodialysis. Methods. A matrix-based approach applicable to linear models encompassing any number of compartments is presented. The procedure requires the inversion of a square matrix and the computation of its eigenvalues λ, assuming they are all distinct. This novel approach bypasses the evaluation of the definite integral to solve the inhomogeneous ordinary differential equation. Results. For urea two out of four eigenvalues describing the changes of concentrations in time are about 105 times larger than the other eigenvalues indicating that the 4-compartment model essentially reduces to the 2-compartment regional blood flow model. In case of creatinine, however, the distribution of eigenvalues is more balanced (a factor of 102 between the largest and the smallest eigenvalue indicating that all four compartments contribute to creatinine kinetics in hemodialysis. Interpretation. Apart from providing an exact analytic solution for practical applications such as the identification of relevant model and treatment parameters, the matrix-based approach reveals characteristic details on model symmetry and complexity for different solutes.

  20. Multi-scale modelling of ions in solution: from atomistic descriptions to chemical engineering

    International Nuclear Information System (INIS)

    Molina, J.J.

    2011-01-01

    Ions in solution play a fundamental role in many physical, chemical, and biological processes. The PUREX process used in the nuclear industry to the treatment of spent nuclear fuels is considered as an example. For industrial applications these systems are usually described using simple analytical models which are fitted to reproduce the available experimental data. In this work, we propose a multi-scale coarse graining procedure to derive such models from atomistic descriptions. First, parameters for classical force-fields of ions in solution are extracted from ab-initio calculations. Effective (McMillan-Mayer) ion-ion potentials are then derived from radial distribution functions measured in classical molecular dynamics simulations, allowing us to define an implicit solvent model of electrolytes. Finally, perturbation calculations are performed to define the best possible representation for these systems, in terms of charged hard-sphere models. Our final model is analytical and contains no free 'fitting' parameters. It shows good agreement with the exact results obtained from Monte-Carlo simulations for the thermodynamic and structural properties. Development of a similar model for the electrolyte viscosity, from information derived from atomistic descriptions, is also introduced. (author)

  1. Application of Homotopy-Perturbation Method to Nonlinear Ozone Decomposition of the Second Order in Aqueous Solutions Equations

    DEFF Research Database (Denmark)

    Ganji, D.D; Miansari, Mo; B, Ganjavi

    2008-01-01

    In this paper, homotopy-perturbation method (HPM) is introduced to solve nonlinear equations of ozone decomposition in aqueous solutions. HPM deforms a di¢ cult problem into a simple problem which can be easily solved. The effects of some parameters such as temperature to the solutions are consid......In this paper, homotopy-perturbation method (HPM) is introduced to solve nonlinear equations of ozone decomposition in aqueous solutions. HPM deforms a di¢ cult problem into a simple problem which can be easily solved. The effects of some parameters such as temperature to the solutions...

  2. Solution of adsorption problems involving steep moving profiles

    DEFF Research Database (Denmark)

    Kiil, Søren; Bhatia, Suresh K.

    1998-01-01

    The moving finite element collocation method proposed by Kiil et al. (1995) for solution of problems with steep gradients is further developed to solve transient problems arising in the field of adsorption. The technique is applied to a model of adsorption in solids with bidisperse pore structures....... Numerical solutions were found to match the analytical solution when it exists (i.e. when the adsorption isotherm is linear). Results of this application study show that the method is simple yet sufficiently accurate for use in adsorption problems with steep moving gradients, where global collocation...

  3. Adaptation and innovation: a grounded theory study of procedural variation in the academic surgical workplace.

    Science.gov (United States)

    Apramian, Tavis; Watling, Christopher; Lingard, Lorelei; Cristancho, Sayra

    2015-10-01

    Surgical research struggles to describe the relationship between procedural variations in daily practice and traditional conceptualizations of evidence. The problem has resisted simple solutions, in part, because we lack a solid understanding of how surgeons conceptualize and interact around variation, adaptation, innovation, and evidence in daily practice. This grounded theory study aims to describe the social processes that influence how procedural variation is conceptualized in the surgical workplace. Using the constructivist grounded theory methodology, semi-structured interviews with surgeons (n = 19) from four North American academic centres were collected and analysed. Purposive sampling targeted surgeons with experiential knowledge of the role of variations in the workplace. Theoretical sampling was conducted until a theoretical framework representing key processes was conceptually saturated. Surgical procedural variation was influenced by three key processes. Seeking improvement was shaped by having unsolved procedural problems, adapting in the moment, and pursuing personal opportunities. Orienting self and others to variations consisted of sharing stories of variations with others, taking stock of how a variation promoted personal interests, and placing trust in peers. Acting under cultural and material conditions was characterized by being wary, positioning personal image, showing the logic of a variation, and making use of academic resources to do so. Our findings include social processes that influence how adaptations are incubated in surgical practice and mature into innovations. This study offers a language for conceptualizing the sociocultural influences on procedural variations in surgery. Interventions to change how surgeons interact with variations on a day-to-day basis should consider these social processes in their design. © 2015 John Wiley & Sons, Ltd.

  4. Recovery of plutonium from oxalate bearing solutions using a mixture of CMPO and TBP

    International Nuclear Information System (INIS)

    Mathur, J.N.; Murali, M.S.; Rizvi, G.H.; Iyer, R.H.; Badheka, L.P.; Banerji, A.; Michael, K.M.; Kapoor, S.C.; Dhumwad, R.K.

    1993-01-01

    A simple and efficient procedure has been developed to quantitatively recover Pu from oxalate bearing solutions using a mixture of octyl(phenyl)-N,N-diisobutylcarbamoylmethylphosphine oxide (CMPO) and TBP in dodecane. Pu(IV) in the range of 6.9 to 34.6 mg/1 was quantitatively extracted into 0.2 M CMPO+ 1.2 M TBP in dodecane from an aqueous solution containing 3.0 M HNO 3 and 0.1 M H 2 C 2 O 4 . At such low concentrations of Pu, the distribution ratio (D) did not change but the increase in oxalic acid concentration drastically reduced these values. The variation in HNO 3 concentration at a fixed concentration of 0.2 M CMPO + 1.2 M TBP has shown a dramatic increase in the D values, being 0.3 at 1.0 M and > 10 4 at 7.5 M. The extraction was almost quantitative even at the aqueous to organic ratio of 10:1. Plutonium could be quantitatively recovered (i) by stripping with 0.5 M acetic acid and (ii) by coprecipitating it directly from the organic phase with 0.3 M oxalic acid + 0.3 M calcium nitrate + sodium nitrite. ∼ 92% of the Pu was found in the precipitate and ∼7% in the supernatant. Using this procedure Pu, in a concentrated form (∼50 times), could be recovered from the oxalate bearing solutions without recourse to the destruction of oxalate ion. The slope of 2 from the nitrate ion as well as CMPO variation experiments suggest the species in the organic phase to be PuC 2 O 4 (NO 3 ) 2 .2CMPO. The absorption spectral study of Pu(IV) confirmed the above species in the organic phase. (author). 19 refs., 5 figs., 9 tabs

  5. Is it possible to protect constitutional rights through simple procedural law

    International Nuclear Information System (INIS)

    Dolde, K.P.

    1982-01-01

    In the administration of justice and in legal literature of the Federal Republic of Germany increasingly more emphasis has been placed on the significance of procedural rights for the realization of basic civil rights, as they were defined in the constitution. Especially in the decision concerning the nuclear power plant at Muehlheim-Kaerlich, the Federal Constitutional Court has stressed the protection of constitutional rights by hearing the case in conjunction with the question of licensing of large industrial plants. Relevant to the protection of basic civil and constitutional rights are, according to the court, not only those regulations as prescribed by the constitution, but also those which, according to the will of the legislature, principally guarantee a constitutional right. The protection of basic rights is thus also guaranteed by civil rights, and not only through the constitution. In the opinion of the author, this will cause serious repercussions which should make corrections of this type of administration of justice necessary. (WBI) [de

  6. Siemens IT solutions for power sector

    International Nuclear Information System (INIS)

    Lunter, P.

    2004-01-01

    The cost reduction, flexibility and revenue increase, potential exploitation, productivity increase, and business opportunities exploitation - that is all what can be required in the races for the promonent positioning on the electricity power market. These requirements can be realized by the sophisticated IT solutions hand-tailored to the special requirements of the electric power producers and tradesmen. This approach makes it possible to achieve greater profit. Our solutions 'PROFIT Solutions', that are symbiosis of the most progressive information technologies and the power plant techniques of the company Siemens, satisfy submitted specifications in substantial measure. The system solutions 'PROFIT Solutions' comprise three solution groups: process, operation a business. The solutions of the group 'IT Process Solutions' increase flexibility and manoeuvrability of equipment, improve the efficiency and contribute to more economical operation of the power generation. Solutions 'IT Process Solutions' simplify and shorten the period of power cycles and conduce to higher labour productivity. Solutions group 'IT Process Solutions' approaches equipment to the market - supports the profit strategies, helps quickly and expertly to determine and predict hazards. The extension PROFIT Cockpit means the nuance to the solutions world 'PROFIT Solutions'. The survey about the whole installation is within reach at the simple touch of a button. It is possible to compile the total system part by part from single solutions 'PROFIT Solutions'. As a matter of fact all single parts can be interconnected with already existing solutions. Routines 'PROFIT Solutions' cooperate with all modern control systems. (author)

  7. Spring Recipes A Problem-solution Approach

    CERN Document Server

    Long, Josh; Mak, Gary

    2010-01-01

    With over 3 Million users/developers, Spring Framework is the leading "out of the box" Java framework. Spring addresses and offers simple solutions for most aspects of your Java/Java EE application development, and guides you to use industry best practices to design and implement your applications. The release of Spring Framework 3 has ushered in many improvements and new features. Spring Recipes: A Problem-Solution Approach, Second Edition continues upon the bestselling success of the previous edition but focuses on the latest Spring 3 features for building enterprise Java applications.

  8. A simple but usually fast branch-and-bound algorithm for the capacitated facility location problem

    DEFF Research Database (Denmark)

    Görtz, Simon; Klose, Andreas

    2012-01-01

    This paper presents a simple branch-and-bound method based on Lagrangean relaxation and subgradient optimization for solving large instances of the capacitated facility location problem (CFLP) to optimality. To guess a primal solution to the Lagrangean dual, we average solutions to the Lagrangean...... subproblem. Branching decisions are then based on this estimated (fractional) primal solution. Extensive numerical results reveal that the method is much faster and more robust than other state-of-the-art methods for solving the CFLP exactly....

  9. Is the stripping technique a tissue-sparing procedure in large simple ovarian cysts in children?

    Science.gov (United States)

    Arena, Francesco; Romeo, Carmelo; Castagnetti, Marco; Scalfari, GianFranco; Cimador, Marcello; Impellizzeri, Pietro; Villari, Daniela; Zimbaro, Fabrizio; DeGrazia, Enrico

    2008-07-01

    Stripping of the cystic wall is performed by gynecologists to treat large ovarian cysts. Information in the pediatric population is poor. We prospectively evaluated the pathologic specimens of large ovarian cyst to determine whether the stripping technique is a tissue-sparing procedure even in this age. We evaluated 5 patients. Samples were taken from the intermediate part of the cystic wall and from the layer covering the cyst during excision. The presence of ovarian tissue adjacent to the cyst wall, and the morphological features of the surrounding tissue were both evaluated. Pelvic ultrasound follow-up was also performed. Patients' mean age was 4.5 years (7 days to 12 years). All cysts were removed because all were symptomatic. The mean diameter was 86.6 mm (74-100 mm). Cysts were follicular in 2 cases, serous in other two, and endometriotic in 1 case. Adjacent ovarian tissue was present in 1 of 5 specimens and was approximately 1 to 2 mm in thickness. The layer adjacent to the cystic wall always appeared as normal ovarian tissue. Ultrasound scans at follow-up revealed presence of ovarian tissue. The stripping procedure for large ovarian cyst excision allows to spare the adjacent normal ovarian tissue even in pediatric age because ovarian tissue is rarely excised with the cyst wall during the procedure.

  10. Procedure for plutonium determination using Pu(VI) spectra

    International Nuclear Information System (INIS)

    Walker, L.F.; Temer, D.J.; Jackson, D.D.

    1996-01-01

    This document describes a simple spectrophotometric method for determining total plutonium in nitric acid solutions based on the spectrum of Pu(VI). Plutonium samples in nitric acid are oxidized to Pu(VI) with Ce(IV) and the net absorbance at the 830 nm peak is measured

  11. Análise de imagem em química analítica: empregando metodologias simples e didáticas para entender e prevenir o escurecimento de tecidos vegetais Image analysis in analytical chemistry: didactic and simple methodologies to understand and prevent the browning of vegetable tissues

    Directory of Open Access Journals (Sweden)

    Karina Omuro Lupetti

    2005-06-01

    Full Text Available A simple and didactic experiment was developed for image monitoring of the browning of fruit tissues caused by the enzyme polyphenol oxidase. The procedure, easy and inexpensive, is a valuable tool to teach and demonstrate the redox reaction between the enzyme and the natural polyphenols. To obtain the browning percentage for apple, pear and banana, digital photographs were employed, and the images were analyzed by means of Monte Carlo methods and digital analysis programs. The effects of several experimental conditions were studied, such as pH, light, temperature and the presence of oxygen or anti-oxidants. It was observed that each fruit presented a different condition that better minimized the oxidation process. The absence of oxygen and the application of a bissulphite solution were sufficient to keep the quality of all fruits tested.

  12. Extraction of soil solution by drainage centrifugation—effects of centrifugal force and time of centrifugation on soil moisture recovery and solute concentration in soil moisture of loess subsoils

    NARCIS (Netherlands)

    Fraters, D.; Boom, G.J.F.L.; Boumans, L.J.M.; Weerd, H. de; Wolters, M.

    2017-01-01

    The solute concentration in the subsoil beneath the root zone is an important parameter for leaching assessment. Drainage centrifugation is considered a simple and straightforward method of determining soil solution chemistry. Although several studies have been carried out to determine whether this

  13. Numerical method for solution of transient, homogeneous, equilibrium, two-phase flows in one space dimension

    International Nuclear Information System (INIS)

    Shin, Y.W.; Wiedermann, A.H.

    1979-10-01

    A solution method is presented for transient, homogeneous, equilibrium, two-phase flows of a single-component fluid in one space dimension. The method combines a direct finite-difference procedure and the method of characteristics. The finite-difference procedure solves the interior points of the computing domain; the boundary information is provided by a separate procedure based on the characteristics theory. The solution procedure for boundary points requires information in addition to the physical boundary conditions. This additional information is obtained by a new procedure involving integration of characteristics in the hodograph plane. Sample problems involving various combinations of basic boundary types are calculated for two-phase water/steam mixtures and single-phase nitrogen gas, and compared with independent method-of-characteristics solutions using very fine characteristic mesh. In all cases, excellent agreement is demonstrated

  14. Procedure to use phosphogypsum industrial waste for mineral CO{sub 2} sequestration

    Energy Technology Data Exchange (ETDEWEB)

    Cardenas-Escudero, C. [Departamento de Fisica de la Materia Condensada, Facultad de Fisica, Universidad de Sevilla, Av. Reina Mercedes s/n, 41012 Seville (Spain); Instituto de Ciencia de Materiales de Sevilla (CSIC-US), Av. Americo Vespucio, 49, 41092 Seville (Spain); Morales-Florez, V., E-mail: victor.morales@icmse.csic.es [Instituto de Ciencia de Materiales de Sevilla (CSIC-US), Av. Americo Vespucio, 49, 41092 Seville (Spain); Perez-Lopez, R. [Departamento de Geologia, Facultad de Ciencias Experimentales, Universidad de Huelva, Campus Universitario Campus del Carmen, Avenida de las Fuerzas Armadas, 21071 Huelva (Spain); Instituto de Diagnostico Ambiental y Estudios del Agua (IDAeA-CSIC), Jordi Girona 18, 08034 Barcelona (Spain); Santos, A. [Departamento de Ciencias de la Tierra, Universidad de Cadiz, Campus del Rio San Pedro, Av. Republica Saharaui s/n, 11510 Puerto Real (Spain); Esquivias, L. [Departamento de Fisica de la Materia Condensada, Facultad de Fisica, Universidad de Sevilla, Av. Reina Mercedes s/n, 41012 Seville (Spain); Instituto de Ciencia de Materiales de Sevilla (CSIC-US), Av. Americo Vespucio, 49, 41092 Seville (Spain)

    2011-11-30

    Highlights: Black-Right-Pointing-Pointer Phosphogypsum wastes are proposed to reduce CO{sub 2} greenhouse gas emissions. Black-Right-Pointing-Pointer Phosphogypsum dissolution with NaOH results in Ca(OH){sub 2} precipitation and Na{sub 2}SO{sub 4}. Black-Right-Pointing-Pointer Aqueous carbonation of Ca(OH){sub 2} with CO{sub 2} results in the CaCO{sub 3} precipitation. Black-Right-Pointing-Pointer Metals contained in the phosphogypsum are transferred to the final calcite. Black-Right-Pointing-Pointer Applications of CaCO{sub 3} and Na{sub 2}SiO{sub 4} by-products are proposed to improve viability. - Abstract: Industrial wet phosphoric acid production in Huelva (SW Spain) has led to the controversial stockpiling of waste phosphogypsum by-products, resulting in the release of significant quantities of toxic impurities in salt marshes in the Tinto river estuary. In the framework of the fight against global climate change and the effort to reduce carbon dioxide emissions, a simple and efficient procedure for CO{sub 2} mineral sequestration is presented in this work, using phosphogypsum waste as a calcium source. Our results demonstrate the high efficiency of portlandite precipitation by phosphogypsum dissolution using an alkaline soda solution. Carbonation experiments performed at ambient pressure and temperature resulted in total conversion of the portlandite into carbonate. The fate of trace elements present in the phosphogypsum waste was also investigated, and trace impurities were found to be completely transferred to the final calcite. We believe that the procedure proposed here should be considered not only as a solution for reducing old stockpiles of phosphogypsum wastes, but also for future phosphoric acid and other gypsum-producing industrial processes, resulting in more sustainable production.

  15. A simple geometrical model describing shapes of soap films suspended on two rings

    Science.gov (United States)

    Herrmann, Felix J.; Kilvington, Charles D.; Wildenberg, Rebekah L.; Camacho, Franco E.; Walecki, Wojciech J.; Walecki, Peter S.; Walecki, Eve S.

    2016-09-01

    We measured and analysed the stability of two types of soap films suspended on two rings using the simple conical frusta-based model, where we use common definition of conical frustum as a portion of a cone that lies between two parallel planes cutting it. Using frusta-based we reproduced very well-known results for catenoid surfaces with and without a central disk. We present for the first time a simple conical frusta based spreadsheet model of the soap surface. This very simple, elementary, geometrical model produces results surprisingly well matching the experimental data and known exact analytical solutions. The experiment and the spreadsheet model can be used as a powerful teaching tool for pre-calculus and geometry students.

  16. A Simple and Reliable Method of Design for Standalone Photovoltaic Systems

    Science.gov (United States)

    Srinivasarao, Mantri; Sudha, K. Rama; Bhanu, C. V. K.

    2017-06-01

    Standalone photovoltaic (SAPV) systems are seen as a promoting method of electrifying areas of developing world that lack power grid infrastructure. Proliferations of these systems require a design procedure that is simple, reliable and exhibit good performance over its life time. The proposed methodology uses simple empirical formulae and easily available parameters to design SAPV systems, that is, array size with energy storage. After arriving at the different array size (area), performance curves are obtained for optimal design of SAPV system with high amount of reliability in terms of autonomy at a specified value of loss of load probability (LOLP). Based on the array to load ratio (ALR) and levelized energy cost (LEC) through life cycle cost (LCC) analysis, it is shown that the proposed methodology gives better performance, requires simple data and is more reliable when compared with conventional design using monthly average daily load and insolation.

  17. Subroutine for series solutions of linear differential equations

    International Nuclear Information System (INIS)

    Tasso, H.; Steuerwald, J.

    1976-02-01

    A subroutine for Taylor series solutions of systems of ordinary linear differential equations is descriebed. It uses the old idea of Lie series but allows simple implementation and is time-saving for symbolic manipulations. (orig.) [de

  18. Preparation standardisation and use of plutonium nitrate reference solutions

    International Nuclear Information System (INIS)

    Brown, M.L.; Drummond, J.L.

    1981-07-01

    A procedure is described for the purification of a plutonium nitrate solution in nitric acid for use as a plutonium master standard. Anion exchange chromatography followed by oxalate precipitation is used to purify the plutonium and the residual cationic impurities are analysed by emission spectroscopy. The plutonium content is accurately and precisely measured by two independent methods, namely by gravimetry as PuO 2 at 1250 0 C and by ceric oxidation, ferrous reduction and dichromate titration. Full details of the purification procedure are given, with recommended methods for storing and using the standard solution. It is concluded that such a solution is the most satisfactory reference material, available for plutonium analysis for reprocessing plants, and is adequately related to other, internationally accepted, standard reference materials. (author)

  19. Nonperturbative Time Dependent Solution of a Simple Ionization Model

    Science.gov (United States)

    Costin, Ovidiu; Costin, Rodica D.; Lebowitz, Joel L.

    2018-02-01

    We present a non-perturbative solution of the Schrödinger equation {iψ_t(t,x)=-ψ_{xx}(t,x)-2(1 +α sinω t) δ(x)ψ(t,x)} , written in units in which \\hbar=2m=1, describing the ionization of a model atom by a parametric oscillating potential. This model has been studied extensively by many authors, including us. It has surprisingly many features in common with those observed in the ionization of real atoms and emission by solids, subjected to microwave or laser radiation. Here we use new mathematical methods to go beyond previous investigations and to provide a complete and rigorous analysis of this system. We obtain the Borel-resummed transseries (multi-instanton expansion) valid for all values of α, ω, t for the wave function, ionization probability, and energy distribution of the emitted electrons, the latter not studied previously for this model. We show that for large t and small α the energy distribution has sharp peaks at energies which are multiples of ω, corresponding to photon capture. We obtain small α expansions that converge for all t, unlike those of standard perturbation theory. We expect that our analysis will serve as a basis for treating more realistic systems revealing a form of universality in different emission processes.

  20. Novel Hyperbolic Homoclinic Solutions of the Helmholtz-Duffing Oscillators

    Directory of Open Access Journals (Sweden)

    Yang-Yang Chen

    2016-01-01

    Full Text Available The exact and explicit homoclinic solution of the undamped Helmholtz-Duffing oscillator is derived by a presented hyperbolic function balance procedure. The homoclinic solution of the self-excited Helmholtz-Duffing oscillator can also be obtained by an extended hyperbolic perturbation method. The application of the present homoclinic solutions to the chaos prediction of the nonautonomous Helmholtz-Duffing oscillator is performed. Effectiveness and advantage of the present solutions are shown by comparisons.

  1. Automated addition of Chelex solution to tubes containing trace items

    DEFF Research Database (Denmark)

    Stangegaard, Michael; Hansen, Thomas Møller; Hansen, Anders Johannes

    2011-01-01

    Extraction of DNA from trace items for forensic genetic DNA typing using a manual Chelex based extraction protocol requires addition of Chelex solution to sample tubes containing trace items. Automated of addition of Chelex solution may be hampered by high viscosity of the solution and fast...... sedimentation rate of the Chelex beads. Here, we present a simple method that can be used on an Eppendorf epMotion liquid handler resolving these issues...

  2. Asymptotic Behavior of Periodic Wave Solution to the Hirota—Satsuma Equation

    International Nuclear Information System (INIS)

    Wu Yong-Qi

    2011-01-01

    The one- and two-periodic wave solutions for the Hirota—Satsuma (HS) equation are presented by using the Hirota derivative and Riemann theta function. The rigorous proofs on asymptotic behaviors of these two solutions are given such that soliton solution can be obtained from the periodic wave solution in an appropriate limiting procedure. (general)

  3. Gauge boson mass without a Higgs field: a simple model

    International Nuclear Information System (INIS)

    Nicholson, A.F.; Kennedy, D.C.

    1997-02-01

    A simple, anomaly-free chiral gauge theory can be perturbatively quantized and renormalized in such a way as to generate fermion and gauge boson masses. This development exploits certain freedoms inherent in choosing the unperturbed Lagrangian and in the renormalization procedure. Apart from its intrinsic interest, such a mechanism might be employed in electroweak gauge theory to generate fermion and gauge boson masses without a Higgs sector. 38 refs

  4. Safety and efficacy of procedural sedation and analgesia (PSA ...

    African Journals Online (AJOL)

    Safety and efficacy of procedural sedation and analgesia (PSA) conducted by medical officers in a level 1 hospital in Cape Town. ... Respiratory complications were treated with simple airway manoeuvres; no patient required intubation or experienced respiratory problems after waking up. There was no significant difference ...

  5. Negotiated Crime Solutions in Portuguese Law: A nowadays reality in a far-away galaxy?

    Directory of Open Access Journals (Sweden)

    André Ferreira de Oliveira

    2017-03-01

    Full Text Available The ideas of procedural consensus and celerity increasingly shape the Criminal Procedural Law of Democratic countries. Negotiated criminal justice solutions have been multiplying in the last years, posing a multiplicity of challenges to the pure and traditional procedural doctrine, to the rights traditionally assured to the procedural actors, being important to question if the (even more organized criminality and the transnational and technological methods of crime did not shift the center of the confrontation between the efficient administration of justice and the rights of the accused. The Portuguese Republic is no exception: without a legislative framework explicitly guarantying a way to benefit those who collaborate with Justice, one must first question if the Criminal Procedural Code allows or may allow criminal Justice negotiated solutions; we will analyze some foreseen legal solutions of consensualism, not forgeting the Portuguese doctrine and courts decisions.

  6. On the validity of the arithmetic-geometric mean method to locate the optimal solution in a supply chain system

    Science.gov (United States)

    Chung, Kun-Jen

    2012-08-01

    Cardenas-Barron [Cardenas-Barron, L.E. (2010) 'A Simple Method to Compute Economic order Quantities: Some Observations', Applied Mathematical Modelling, 34, 1684-1688] indicates that there are several functions in which the arithmetic-geometric mean method (AGM) does not give the minimum. This article presents another situation to reveal that the AGM inequality to locate the optimal solution may be invalid for Teng, Chen, and Goyal [Teng, J.T., Chen, J., and Goyal S.K. (2009), 'A Comprehensive Note on: An Inventory Model under Two Levels of Trade Credit and Limited Storage Space Derived without Derivatives', Applied Mathematical Modelling, 33, 4388-4396], Teng and Goyal [Teng, J.T., and Goyal S.K. (2009), 'Comment on 'Optimal Inventory Replenishment Policy for the EPQ Model under Trade Credit Derived without Derivatives', International Journal of Systems Science, 40, 1095-1098] and Hsieh, Chang, Weng, and Dye [Hsieh, T.P., Chang, H.J., Weng, M.W., and Dye, C.Y. (2008), 'A Simple Approach to an Integrated Single-vendor Single-buyer Inventory System with Shortage', Production Planning and Control, 19, 601-604]. So, the main purpose of this article is to adopt the calculus approach not only to overcome shortcomings of the arithmetic-geometric mean method of Teng et al. (2009), Teng and Goyal (2009) and Hsieh et al. (2008), but also to develop the complete solution procedures for them.

  7. Existence criterion of spurious solutions of Faddeev equations

    International Nuclear Information System (INIS)

    Pupyshev, V.V.

    1995-01-01

    The Faddeev differential equations for a system of three different particles interacting via central two-body potentials are investigated within the hyperharmonics approach. A simple method for classification and construction of these solutions is proposed. 25 refs

  8. Semi-simple continued fractions and diophantine equations for real quadratic fields

    International Nuclear Information System (INIS)

    Zhang Xianke.

    1994-09-01

    Main theorem: the equation x 2 - my 2 = c has an integer solution if and only if c = (-1) i Q i for some semi-simple continued-fraction expansion √m = [b 0 , b 1 , b 2 , ...] and some 0 ≤ i is an element of Z, where Q i denotes the i-th complete denominator of the expansion, i.e. [b i , b i+1 ,...] = (√m + P i )/Q i (P i , Q i is an element of Z). Here by semi-simple one means b i could be negative (and positive) integers. Such expansion with minimal modul Q i are also discussed. (author). 9 refs

  9. Modified SIMPLE algorithm for the numerical analysis of incompressible flows with free surface

    International Nuclear Information System (INIS)

    Mok, Jin Ho; Hong, Chun Pyo; Lee, Jin Ho

    2005-01-01

    While the SIMPLE algorithm is most widely used for the simulations of flow phenomena that take place in the industrial equipment or the manufacturing processes, it is less adopted for the simulations of the free surface flow. Though the SIMPLE algorithm is free from the limitation of time step, the free surface behavior imposes the restriction on the time step. As a result, the explicit schemes are faster than the implicit scheme in terms of computation time when the same time step is applied to, since the implicit scheme includes the numerical method to solve the simultaneous equations in its procedure. If the computation time of SIMPLE algorithm can be reduced when it is applied to the unsteady free surface flow problems, the calculation can be carried out in the more stable way and, in the design process, the process variables can be controlled based on the more accurate data base. In this study, a modified SIMPLE algorithm is presented for the free surface flow. The broken water column problem is adopted for the validation of the modified algorithm (MoSIMPLE) and for comparison to the conventional SIMPLE algorithm

  10. Integrated Practice Improvement Solutions-Practical Steps to Operating Room Management.

    Science.gov (United States)

    Chernov, Mikhail; Pullockaran, Janet; Vick, Angela; Leyvi, Galina; Delphin, Ellise

    2016-10-01

    Perioperative productivity is a vital concern for surgeons, anesthesiologists, and administrators as the OR is a major source of hospital elective admissions and revenue. Based on elements of existing Practice Improvement Methodologies (PIMs), "Integrated Practice Improvement Solutions" (IPIS) is a practical and simple solution incorporating aspects of multiple management approaches into a single open source framework to increase OR efficiency and productivity by better utilization of existing resources. OR efficiency was measured both before and after IPIS implementation using the total number of cases versus room utilization, OR/anesthesia revenue and staff overtime (OT) costs. Other parameters of efficiency, such as the first case on-time start and the turnover time (TOT) were measured in parallel. IPIS implementation resulted in increased numbers of surgical procedures performed by an average of 10.7%, and OR and anesthesia revenue increases of 18.5% and 6.9%, respectively, with a simultaneous decrease in TOT (15%) and OT for anesthesia staff (26%). The number of perioperative adverse events was stable during the two-year study period which involved a total of 20,378 patients. IPIS, an effective and flexible practice improvement model, was designed to quickly, significantly, and sustainably improve OR efficiency by better utilization of existing resources. Success of its implementation directly correlates with the involvement of and acceptance by the entire OR team and hospital administration.

  11. Comparison of a continuous suture pattern with a simple interrupted pattern for enteric closure in dogs and cats: 83 cases (1991-1997).

    Science.gov (United States)

    Weisman, D L; Smeak, D D; Birchard, S J; Zweigart, S L

    1999-05-15

    To describe and compare a simple continuous suture pattern with a simple interrupted pattern for enterotomy closure or end-to-end intestinal anastomosis. Retrospective study. 58 dogs and 25 cats that underwent enterotomy or intestinal resection and anastomosis. Signalment, surgical procedure, suture pattern, suture material, confirmation of dehiscence, and follow-up were reviewed. Groups were compared by procedure (anastomosis or enterotomy) and by suture pattern. 57 animals underwent continuous closure; 26 had interrupted closure. Only polydioxanone or polypropylene suture materials were used. Overall, 81 (98%) animals had no signs of intestinal dehiscence and survived > 2 weeks. Two animals had confirmed dehiscence after foreign body removal, 1 of 57 (2%) after continuous closure, and 1 of 26 (4%) after interrupted closure. The simple continuous closure pattern is an acceptable alternative to simple interrupted closure for small intestinal anastomosis or enterotomy closure.

  12. Biosorption of gold from computer microprocessor leachate solutions using chitin.

    Science.gov (United States)

    Côrtes, Letícia N; Tanabe, Eduardo H; Bertuol, Daniel A; Dotto, Guilherme L

    2015-11-01

    The biosorption of gold from discarded computer microprocessor (DCM) leachate solutions was studied using chitin as a biosorbent. The DCM components were leached with thiourea solutions, and two procedures were tested for recovery of gold from the leachates: (1) biosorption and (2) precipitation followed by biosorption. For each procedure, the biosorption was evaluated considering kinetic, equilibrium, and thermodynamic aspects. The general order model was able to represent the kinetic behavior, and the equilibrium was well represented by the BET model. The maximum biosorption capacities were around 35 mg g(-1) for both procedures. The biosorption of gold on chitin was a spontaneous, favorable, and exothermic process. It was found that precipitation followed by biosorption resulted in the best gold recovery, because other species were removed from the leachate solution in the precipitation step. This method enabled about 80% of the gold to be recovered, using 20 g L(-1) of chitin at 298 K for 4 h. Copyright © 2015 Elsevier Ltd. All rights reserved.

  13. Traveling Wave Solutions of ZK-BBM Equation Sine-Cosine Method

    Directory of Open Access Journals (Sweden)

    Sadaf Bibi

    2014-03-01

    Full Text Available Travelling wave solutions are obtained by using a relatively new technique which is called sine-cosine method for ZK-BBM equations. Solution procedure and obtained results re-confirm the efficiency of the proposed scheme.

  14. Simple test of synergy between ampicillin and vancomycin for resistant strains of Enterococcus faecium.

    Science.gov (United States)

    Green, M; Barbadora, K; Wadowsky, R M

    1994-11-01

    The combination of ampicillin and vancomycin kills some but not all strains of ampicillin- and vancomycin-resistant Enterococcus faecium. We compared a simple test for synergy utilizing a commercially available microdilution susceptibility system with time-kill studies and determined acceptable breakpoints for this test for 20 strains of ampicillin- and vancomycin-resistant E. faecium. The combination of ampicillin and vancomycin was tested for synergy by time-kill, broth macrodilution, and broth microdilution procedures. Repeat testing of isolates by macro- and microdilution synergy methods yielded MICs that were within one twofold dilution of each other for both intra- and intertest comparisons. Synergy was always detected by time-kill studies when the MIC of ampicillin in the combination synergy screen was 16 micrograms/ml in the combination microdilution synergy screen. The determination of the synergy by the broth microdilution procedure appears to be simple, convenient, and accurate.

  15. Simple method for correct enumeration of Staphylococcus aureus

    DEFF Research Database (Denmark)

    Haaber, J.; Cohn, M. T.; Petersen, A.

    2016-01-01

    culture. When grown in such liquid cultures, the human pathogen Staphylococcus aureus is characterized by its aggregation of single cells into clusters of variable size. Here, we show that aggregation during growth in the laboratory standard medium tryptic soy broth (TSB) is common among clinical...... and laboratory S. aureus isolates and that aggregation may introduce significant bias when applying standard enumeration methods on S. aureus growing in laboratory batch cultures. We provide a simple and efficient sonication procedure, which can be applied prior to optical density measurements to give...

  16. SIMPLE ESTIMATOR AND CONSISTENT STRONGLY OF STABLE DISTRIBUTIONS

    Directory of Open Access Journals (Sweden)

    Cira E. Guevara Otiniano

    2016-06-01

    Full Text Available Stable distributions are extensively used to analyze earnings of financial assets, such as exchange rates and stock prices assets. In this paper we propose a simple and strongly consistent estimator for the scale parameter of a symmetric stable L´evy distribution. The advantage of this estimator is that your computational time is minimum thus it can be used to initialize intensive computational procedure such as maximum likelihood. With random samples of sized n we tested the efficacy of these estimators by Monte Carlo method. We also included applications for three data sets.

  17. Solutions to higher hamiltonians in the Toda hierarchies

    International Nuclear Information System (INIS)

    Ferreira, L.A.; Londe, R.M.

    1988-01-01

    We present a method for constructing the general solution to higher hamiltonians of the Toda hierarchies of integrable models associated to a simple Lie group G. The method depends on some special properties of the representations of the Lie algebra of G and it constitutes a generalization of the method used to construct the solutions of the Toda Molecula models. The SL(3) and SL(4) cases are discussed in detail. (author) [pt

  18. Procedures for determining MATMOD-4V material constants

    Energy Technology Data Exchange (ETDEWEB)

    Lowe, T.C.

    1993-11-01

    The MATMOD-4V constitutive relations were developed from the original MATMOD model to extend the range of nonelastic deformation behaviors represented to include transient phenomena such as strain softening. Improvements in MATMOD-4V increased the number of independent material constants and the difficulty in determining their values. Though the constitutive relations are conceptually simple, their form and procedures for obtaining their constants can be complex. This paper reviews in detail the experiments, numerical procedures, and assumptions that have been used to determine a complete set of MATMOD-4V constants for high purity aluminum.

  19. Lorentz Trial Function for the Hydrogen Atom: A Simple, Elegant Exercise

    Science.gov (United States)

    Sommerfeld, Thomas

    2011-01-01

    The quantum semester of a typical two-semester physical chemistry course is divided into two parts. The initial focus is on quantum mechanics and simple model systems for which the Schrodinger equation can be solved in closed form, but it then shifts in the second half to atoms and molecules, for which no closed solutions exist. The underlying…

  20. Solute–Solute Interaction In α IRON: The Status QUO

    Directory of Open Access Journals (Sweden)

    Numakura H.

    2015-09-01

    Full Text Available An overview is presented on the interaction of substitutional solutes with carbon and nitrogen in α iron, which is an important factor in controlling the properties of steels. Starting from a simple model of trapping of the interstitial solute atoms by substitutional solute atoms, the principles of experimental methods for quantitative studies are described, focussing on the Snoek relaxation and solubility measurements, and the knowledge acquired by such experiments is reviewed. An account of recent theoretical approaches to the interaction is also given.

  1. Procedures monitoring and MAAP analysis

    International Nuclear Information System (INIS)

    May, R.S.

    1991-01-01

    Numerous studies of severe accidents in light water reactors have shown that operator response can play a crucial role in the predicted outcomes of dominant accident scenarios. MAAP provides the capability to specify certain operator actions as input data. However, making reasonable assumptions about the nature and timing of operator response requires substantial knowledge about plant practices and procedures and what they imply for the event being analyzed. The appearance of knowledge based software technology in the mid-1980s provided a natural format for representing and maintaining procedures as IF-THEN rules. The boiling water reactor (BWR) Emergency Operating Procedures Tracking System (EOPTS) was composed of a rule base of procedures and a dedicated inference engine (problem-solver). Based on the general approach and experience of EOPTS, the authors have developed a prototype procedures monitoring system that reads MAAP transient output files and evaluate the EOP messages and instructions that would be implied during each transient time interval. The prototype system was built using the NEXPERT OBJECT expert system development system, running on a 386-class personal computer with 4 MB of memory. The limited scope prototype includes a reduced set of BWR6 EOPs procedures evaluation on a coarse time interval, a simple text-based user interface, and a summary-report generator. The prototype, which is limited to batch-mode analysis of MAAP output, is intended to demonstrate the concept and aid in the design of a production system, which will involve a direct link to MAAP and interactive capabilities

  2. Molecular thermodynamics using fluctuation solution theory

    DEFF Research Database (Denmark)

    Ellegaard, Martin Dela

    . The framework relates thermodynamic variables to molecular pair correlation functions of liquid mixtures. In this thesis, application of the framework is illustrated using two approaches: 1. Solubilities of solid solutes in mixed solvent systems are determined from fluctuation solution theory application......Properties of chemicals and their mutual phase equilibria are critical variables in process design. Reliable estimates of relevant equilibrium properties, from thermodynamic models, can form the basis of good decision making in the development phase of a process design, especially when access...... to relevant experimental data is limited. This thesis addresses the issue of generating and using simple thermodynamic models within a rigorous statistical mechanical framework, the so-called fluctuation solution theory, from which relations connecting properties and phase equilibria can be obtained...

  3. Light scattering from polymer solutions and nanoparticle dispersions

    CERN Document Server

    Schärtl, Wolfgang; Janca, Josef

    2007-01-01

    Light scattering is a very powerful method to characterize the structure of polymers and nanoparticles in solution. Recent technical developments have strongly enhanced the possible applications of this technique, overcoming previous limitations like sample turbidity or insufficient experimental time scales. However, despite their importance, these new developments have not yet been presented in a comprehensive form. In addition, and maybe even more important to the broad audience, there lacks a simple-to-read textbook for students and non-experts interested in the basic principles and fundamental techniques of light scattering. As part of the Springer Laboratory series, this book tries not only to provide such a simple-to-read and illustrative textbook about the seemingly very complicated topic of light scattering from polymers and nanoparticles in dilute solution, but also intends to cover some of the newest technical developments in experimental light scattering.

  4. Cr(OH)3-NPs-CNC hybrid nanocomposite: a sorbent for adsorptive removal of methylene blue and malachite green from solutions.

    Science.gov (United States)

    Nekouei, Farzin; Nekouei, Shahram; Keshtpour, Farzaneh; Noorizadeh, Hossein; Wang, Shaobin

    2017-11-01

    In this article, Cr(OH) 3 nanoparticle-modified cellulose nanocrystal (CNC) as a novel hybrid nanocomposite (Cr(OH) 3 -NPs-CNC) was prepared by a simple procedure and used as a sorbent for adsorptive removal of methylene blue (MB) and malachite green (MG) from aqueous solution. Different kinetic models were tested, and the pseudo-second-order kinetic model was found more suitable for the MB and MG adsorption processes. The BET and Langmuir models were more suitable for the adsorption processes of MB and MG. Thermodynamic studies suggested that the adsorption of MB and MG onto Cr(OH) 3 -NPs-CNC nanocomposite was a spontaneous and endothermic process. The maximum adsorption capacities for MB and MG were reached 106 and 104 mg/g, respectively, which were almost two times higher than unmodified CNC. The chemical stability and leaching tests of the Cr(OH) 3 -NPs-CNC hybrid nanocomposite showed that only small amounts of chromium were leached into the solution.

  5. Proposing buffer zones and simple technical solutions for safeguarding river water quality and public health

    Science.gov (United States)

    Podimata, M. V.; Bekri, E. S.; Yannopoulos, P. C.

    2012-04-01

    Alfeios River Basin (ARB) constitutes one of the major hydrologic basins (≈3650km2) of Peloponnisos peninsula in Southern Greece. It is drained by Alfeios River and its tributaries, such as Lousios, Ladhon, Erymanthos, Kladheos, Selinous etc. The present manuscript takes a closer look at the importance of tributary basins and focuses on Erymanthos sub-basin that covers about 360 km2. Erymanthos River springs from Erymanthos Mountain that reaches altitudes of 2200 m and discharges 10 m3/sec, approximately, during the winter period, presenting a sound decrease from half to about an order of magnitude during summertime. Two factors stand out as reasons to select Erymanthos sub-basin as a case study. First, the sub-basin presents a significant variety of ecosystems and comprises a very important river system, since Erymanthos Tributary satisfies, among other uses, drinking water supply for a great majority of citizens in the region. Second, authors' experience of the study area in Research Program Pythagoras II, funded by the European Social Fund (ESF) and the Operational Program for Educational and Vocational Training II (EPEAEK II) of Greece, offers a basis for better understanding of the real problems in the area. Erymanthos watershed, in fact, faces a lot of pressures, in several levels, provoked by human activities and Erymanthos Tributary is vulnerable to pollution. Recognizing the importance of clean water for healthy people, a developing economy, and a sustainable environment, the challenge of the present paper is elaborating human-induced pressures in the study area, analyzing their effects, estimating pollution factors and proposing integrated solutions/tools and a number of methodologies/initiatives used to overcome the problem of contaminating water supply in a catchment that lacks of wastewater treatment and disposal systems. The preservation of a good ecological status in Erymanthos River is not only a necessity for achieving the goals of EU Water

  6. The spring balance: a simple monitoring system for fluid overload during hysteroscopic surgery

    NARCIS (Netherlands)

    Ankum, W. M.; Vonk, J.

    1994-01-01

    Fluid overload may arise during hysteroscopic surgery, caused by absorption of fluid used to distend the uterus. Continuous monitoring of the fluid balance is required to prevent this serious complication. Commercial equipment does not serve this purpose adequately. We describe a simple solution. We

  7. PROCESS OF ELIMINATING HYDROGEN PEROXIDE IN SOLUTIONS CONTAINING PLUTONIUM VALUES

    Science.gov (United States)

    Barrick, J.G.; Fries, B.A.

    1960-09-27

    A procedure is given for peroxide precipitation processes for separating and recovering plutonium values contained in an aqueous solution. When plutonium peroxide is precipitated from an aqueous solution, the supernatant contains appreciable quantities of plutonium and peroxide. It is desirable to process this solution further to recover plutonium contained therein, but the presence of the peroxide introduces difficulties; residual hydrogen peroxide contained in the supernatant solution is eliminated by adding a nitrite or a sulfite to this solution.

  8. A Simple, Low-cost, and Robust System to Measure the Volume of Hydrogen Evolved by Chemical Reactions with Aqueous Solutions.

    Science.gov (United States)

    Brack, Paul; Dann, Sandie; Wijayantha, K G Upul; Adcock, Paul; Foster, Simon

    2016-08-17

    There is a growing research interest in the development of portable systems which can deliver hydrogen on-demand to proton exchange membrane (PEM) hydrogen fuel cells. Researchers seeking to develop such systems require a method of measuring the generated hydrogen. Herein, we describe a simple, low-cost, and robust method to measure the hydrogen generated from the reaction of solids with aqueous solutions. The reactions are conducted in a conventional one-necked round-bottomed flask placed in a temperature controlled water bath. The hydrogen generated from the reaction in the flask is channeled through tubing into a water-filled inverted measuring cylinder. The water displaced from the measuring cylinder by the incoming gas is diverted into a beaker on a balance. The balance is connected to a computer, and the change in the mass reading of the balance over time is recorded using data collection and spreadsheet software programs. The data can then be approximately corrected for water vapor using the method described herein, and parameters such as the total hydrogen yield, the hydrogen generation rate, and the induction period can also be deduced. The size of the measuring cylinder and the resolution of the balance can be changed to adapt the setup to different hydrogen volumes and flow rates.

  9. An Isotopic Dilution Experiment Using Liquid Scintillation: A Simple Two-System, Two-Phase Analysis.

    Science.gov (United States)

    Moehs, Peter J.; Levine, Samuel

    1982-01-01

    A simple isotonic, dilution analysis whose principles apply to methods of more complex radioanalyses is described. Suitable for clinical and instrumental analysis chemistry students, experimental manipulations are kept to a minimum involving only aqueous extraction before counting. Background information, procedures, and results are discussed.…

  10. Evaluation of adsorption of uranium from aqueous solution using biochar materials

    Energy Technology Data Exchange (ETDEWEB)

    Correa, Wagner Clayton; Guilhen, Sabine Neusatz; Ortiz, Nilce; Fungaro, Denise Alves, E-mail: wcorrea@ipen.br, E-mail: snguilhen@ipen.br, E-mail: notriz@ipen.br, E-mail: dfungaro@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2015-07-01

    Uranium is present in the environment as a result of leaching from natural deposits and activities associated with nuclear fuel, copper mining, uranium mining, milling industry, etc. For the purpose of protecting ecosystem stability and public health, it is crucial to eliminate uranium from aqueous solutions before they are discharged into the environment. Various technologies have been used for removing U(VI) ions from aqueous systems. Among these methods, adsorption has been applied in wastewater because of simple operation procedure and high removal efficiency. Brazil is the largest producer of charcoal in the world, with nearly half of the woody biomass harvested for energy in Brazil being transformed into charcoal. Biochar exhibits a great potential as an adsorbent because of favorable physical/chemical surface characteristics. The objective of this work was to evaluate the adsorption potential of biochar materials prepared from pyrolysis of Bamboo (CBM), Eucalyptus (CEM) and Macauba (CMA) nuts for the removal of uranium from solutions. Adsorption experiments were carried out by a batch technique. Equilibrium adsorption experiments were performed by shaking a known amount of biochar material with 100 mL of U(VI) solution in Erlenmeyer flasks in a shaker at 120 rpm and room temperature (25 deg C) for 24 h. The adsorbent was separated by centrifugation from the solution. The U(VI) concentration remaining in the supernatant solution was determined using inductively coupled plasma optical emission spectrometry (ICP-OES). The influences of different experimental parameters such as solution pH and bioadsorbent dose on adsorption were investigated. The highest uranium adsorption capacity were obtained at pH 3.0 and 16 g/L biomass dosage for CMA, pH 3.0 and 12 g/L biomass dosage for CBM and pH 2.0 and 10 g/L biomass dosage for CEM. The results demonstrated that the biomass derived char can be used as a low-cost adsorbent for removal of uranium from wastewater. (author)

  11. Evaluation of adsorption of uranium from aqueous solution using biochar materials

    International Nuclear Information System (INIS)

    Correa, Wagner Clayton; Guilhen, Sabine Neusatz; Ortiz, Nilce; Fungaro, Denise Alves

    2015-01-01

    Uranium is present in the environment as a result of leaching from natural deposits and activities associated with nuclear fuel, copper mining, uranium mining, milling industry, etc. For the purpose of protecting ecosystem stability and public health, it is crucial to eliminate uranium from aqueous solutions before they are discharged into the environment. Various technologies have been used for removing U(VI) ions from aqueous systems. Among these methods, adsorption has been applied in wastewater because of simple operation procedure and high removal efficiency. Brazil is the largest producer of charcoal in the world, with nearly half of the woody biomass harvested for energy in Brazil being transformed into charcoal. Biochar exhibits a great potential as an adsorbent because of favorable physical/chemical surface characteristics. The objective of this work was to evaluate the adsorption potential of biochar materials prepared from pyrolysis of Bamboo (CBM), Eucalyptus (CEM) and Macauba (CMA) nuts for the removal of uranium from solutions. Adsorption experiments were carried out by a batch technique. Equilibrium adsorption experiments were performed by shaking a known amount of biochar material with 100 mL of U(VI) solution in Erlenmeyer flasks in a shaker at 120 rpm and room temperature (25 deg C) for 24 h. The adsorbent was separated by centrifugation from the solution. The U(VI) concentration remaining in the supernatant solution was determined using inductively coupled plasma optical emission spectrometry (ICP-OES). The influences of different experimental parameters such as solution pH and bioadsorbent dose on adsorption were investigated. The highest uranium adsorption capacity were obtained at pH 3.0 and 16 g/L biomass dosage for CMA, pH 3.0 and 12 g/L biomass dosage for CBM and pH 2.0 and 10 g/L biomass dosage for CEM. The results demonstrated that the biomass derived char can be used as a low-cost adsorbent for removal of uranium from wastewater. (author)

  12. Flotation-Separation of the Pollutant Species of Chromium, Cadmium and Lead from aqueous Solutions and Natural Waters

    International Nuclear Information System (INIS)

    Ghazy, S.E.; Kabil, M.A.; Shallaby, A.M.; Ammar, N.S.

    1999-01-01

    This work aims to present simple, rapid and accurate procedures to recover the pollutant species of chromium, cadmium and lead from different types of water using the flotation technique. To achieve this goal, precipitate flotation was the method of choice for this investigation using oleic acid (HOL) as a surfactant. Cr(III) as its hydroxide and Cr(VI) as Ag 2 CrO 4 or Ag 2 Cr 2 O 7 are removed in 6.5±0.2 and 6-75 ph range, respectively. 2,4,6-Tri(2-pyridyl)-1,3,5-triazine (TPTA), in the presence of KI, is a good collector for quantitative separation of trace amounts of Cd(II) in the ph range 6-7.5. Chloranilic acid (CAA) is found to be the most effective complexing agent for the flotation of trace amounts of Pb(II) over the ph range 4-7. The effects of surfactant and analyte concentrations, foreign ions and temperature have been examined. The application of this procedure to recover these analytes added to natural samples has been investigated. Also, a procedure for sective separation of Cr(III) from Cr(VI) either in aqueous solutions or in saline water is proposed. Moreover, a mechanism of flotation is suggested

  13. Solution weighting for the SAND-II Monte Carlo code

    International Nuclear Information System (INIS)

    Oster, C.A.; McElroy, W.N.; Simons, R.L.; Lippincott, E.P.; Odette, G.R.

    1976-01-01

    Modifications to the SAND-II Error Analysis Monte Carlo code to include solution weighting based on input data uncertainties have been made and are discussed together with background information on the SAND-II algorithm. The new procedure permits input data having smaller uncertainties to have a greater influence on the solution spectrum than do the data having larger uncertainties. The results of an indepth study to find a practical procedure and the first results of its application to three important Interlaboratory LMFBR Reaction Rate (ILRR) program benchmark spectra (CFRMF, ΣΣ, and 235 U fission) are discussed

  14. Crystal nucleation in simple and complex fluids.

    Science.gov (United States)

    Oxtoby, David W

    2003-03-15

    The application of density-functional methods from statistical mechanics to the nucleation of crystals from the melt is described. Simple fluids such as metals, with sizes comparable with the range of their attractive forces, are compared with complex fluids such as colloidal suspensions and proteins dissolved in solution. A different mechanism for crystal nucleation is proposed in the latter case, in which density (concentration) changes before periodic crystalline order appears. This leads to a theoretical foundation for empirical observations on the 'crystallization window' in protein crystallization. Comparisons are made with the results of computer simulation via molecular dynamics.

  15. Automatic control design procedures for restructurable aircraft control

    Science.gov (United States)

    Looze, D. P.; Krolewski, S.; Weiss, J.; Barrett, N.; Eterno, J.

    1985-01-01

    A simple, reliable automatic redesign procedure for restructurable control is discussed. This procedure is based on Linear Quadratic (LQ) design methodologies. It employs a robust control system design for the unfailed aircraft to minimize the effects of failed surfaces and to extend the time available for restructuring the Flight Control System. The procedure uses the LQ design parameters for the unfailed system as a basis for choosing the design parameters of the failed system. This philosophy alloys the engineering trade-offs that were present in the nominal design to the inherited by the restructurable design. In particular, it alloys bandwidth limitations and performance trade-offs to be incorporated in the redesigned system. The procedure also has several other desirable features. It effectively redistributes authority among the available control effectors to maximize the system performance subject to actuator limitations and constraints. It provides a graceful performance degradation as the amount of control authority lessens. When given the parameters of the unfailed aircraft, the automatic redesign procedure reproduces the nominal control system design.

  16. Determination of Pesticides Residues in Cucumbers Grown in Greenhouse and the Effect of Some Procedures on Their Residues.

    Science.gov (United States)

    Leili, Mostafa; Pirmoghani, Amin; Samadi, Mohammad Taghi; Shokoohi, Reza; Roshanaei, Ghodratollah; Poormohammadi, Ali

    2016-11-01

    The objective of this study was to determine the residual concentrations of ethion and imidacloprid in cucumbers grown in greenhouse. The effect of some simple processing procedures on both ethion and imidacloprid residues were also studied. Ten active greenhouses that produce cucumber were randomly selected. Ethion and imidacloprid as the most widely used pesticides were measured in cucumber samples of studied greenhouses. Moreover, the effect of storing, washing, and peeling as simple processing procedures on both ethion and imidacloprid residues were investigated. One hour after pesticide application; the maximum residue levels (MRLs) of ethion and imidacloprid were higher than that of Codex standard level. One day after pesticide application, the levels of pesticides were decreased about 35 and 31% for ethion and imidacloprid, respectively, which still were higher than the MRL. Washing procedure led to about 51 and 42.5% loss in ethion and imidacloprid residues, respectively. Peeling procedure also led to highest loss of 93.4 and 63.7% in ethion and imidacloprid residues, respectively. The recovery for both target analytes was in the range between 88 and 102%. The residue values in collected samples one hour after pesticides application were higher than standard value. The storing, washing, and peeling procedures lead to the decrease of pesticide residues in greenhouse cucumbers. Among them, the peeling procedure has the greatest impact on residual reduction. Therefore, these procedures can be used as simple and effective processing techniques for reducing and removing pesticides from greenhouse products before their consumption.

  17. Single Spore Isolation as a Simple and Efficient Technique to obtain fungal pure culture

    Science.gov (United States)

    Noman, E.; Al-Gheethi, AA; Rahman, N. K.; Talip, B.; Mohamed, R.; H, N.; Kadir, O. A.

    2018-04-01

    The successful identification of fungi by phenotypic methods or molecular technique depends mainly on the using an advanced technique for purifying the isolates. The most efficient is the single spore technique due to the simple requirements and the efficiency in preventing the contamination by yeast, mites or bacteria. The method described in the present work is depends on the using of a light microscope to transfer one spore into a new culture medium. The present work describes a simple and efficient procedure for single spore isolation to purify of fungi recovered from the clinical wastes.

  18. Statistical power analysis a simple and general model for traditional and modern hypothesis tests

    CERN Document Server

    Murphy, Kevin R; Wolach, Allen

    2014-01-01

    Noted for its accessible approach, this text applies the latest approaches of power analysis to both null hypothesis and minimum-effect testing using the same basic unified model. Through the use of a few simple procedures and examples, the authors show readers with little expertise in statistical analysis how to obtain the values needed to carry out the power analysis for their research. Illustrations of how these analyses work and how they can be used to choose the appropriate criterion for defining statistically significant outcomes are sprinkled throughout. The book presents a simple and g

  19. A Generalized Deduction of the Ideal-Solution Model

    Science.gov (United States)

    Leo, Teresa J.; Perez-del-Notario, Pedro; Raso, Miguel A.

    2006-01-01

    A new general procedure for deriving the Gibbs energy of mixing is developed through general thermodynamic considerations, and the ideal-solution model is obtained as a special particular case of the general one. The deduction of the Gibbs energy of mixing for the ideal-solution model is a rational one and viewed suitable for advanced students who…

  20. Remarks about singular solutions to the Dirac equation

    International Nuclear Information System (INIS)

    Uhlir, M.

    1975-01-01

    In the paper singular solutions of the Dirac equation are investigated. They are derived in the Lorentz-covariant way of functions proportional to static multipole fields of scalar and (or) electromagnetic fields and of regular solutions of the Dirac equations. The regularization procedure excluding divergences of total energy, momentum and angular momentum of the spinor field considered is proposed

  1. Are Self-study Procedural Teaching Methods Effective? A Pilot Study of a Family Medicine Residency Program.

    Science.gov (United States)

    Deffenbacher, Brandy; Langner, Shannon; Khodaee, Morteza

    2017-11-01

    A family medicine residency is a unique training environment where residents are exposed to care in multiple settings, across all ages. Procedures are an integral part of family medicine practice. Family medicine residency (FMR) programs are tasked with the job of teaching these skills at a level of intensity and frequency that allows a resident to achieve competency of such skills. In an environment that is limited by work hour restrictions, self-study teaching methods are one way to ensure all residents receive the fundamental knowledge of how to perform procedures. We developed and evaluated the efficacy of a self-study procedure teaching method and procedure evaluation checklist. A self-study procedure teaching intervention was created, consisting of instructional articles and videos on three procedures. To assess the efficacy of the intervention, and the competency of the residents, pre- and postintervention procedure performance sessions were completed. These sessions were reviewed and scored using a standardized procedure performance checklist. All 24 residents participated in the study. Overall, the resident procedure knowledge increased on two of the three procedures studied, and ability to perform procedure according to expert-validated checklist improved significantly on all procedures. A self-study intervention is a simple but effective way to increase and improve procedure training in a way that fits the complex scheduling needs of a residency training program. In addition, this study demonstrates that the procedure performance checklists are a simple and reliable way to increase assessment of resident procedure performance skills in a residency setting.

  2. Anharmonicities of coupled β and γ vibrations discussed in a simple model

    International Nuclear Information System (INIS)

    Piepenbring, R.; Silvestre-Brac, B.; Szymanski, Z.

    1984-01-01

    The multiphonon method based on β and γ phonons is tested in a simple model allowing an exact solution for a many body fermion system where pairing and quadrupole forces are acting. The properties exhibiting the anharmonicities of the lowest-lying vibrational states of positive parity are nicely reproduced by this method. (orig.)

  3. Anharmonicities of coupled β and γ vibrations discussed in a simple model

    International Nuclear Information System (INIS)

    Piepenbring, R.; Silvestre-Brac, B.; Szymanski, Z.

    1983-11-01

    The multiphonon method based on β and γ phonons is tested in a simple model allowing an exact solution for a many body fermion system where pairing and quadrupole forces are acting. The properties exhibiting the anharmonicities of the lowest-lying vibrational states of positive parity are nicely reproduced by this method

  4. Finite-difference solution of the space-angle-lethargy-dependent slowing-down transport equation

    Energy Technology Data Exchange (ETDEWEB)

    Matausek, M V [Boris Kidric Vinca Institute of Nuclear Sciences, Vinca, Belgrade (Yugoslavia)

    1972-07-01

    A procedure has been developed for solving the slowing-down transport equation for a cylindrically symmetric reactor system. The anisotropy of the resonance neutron flux is treated by the spherical harmonics formalism, which reduces the space-angle-Iethargy-dependent transport equation to a matrix integro-differential equation in space and lethargy. Replacing further the lethargy transfer integral by a finite-difference form, a set of matrix ordinary differential equations is obtained, with lethargy-and space dependent coefficients. If the lethargy pivotal points are chosen dense enough so that the difference correction term can be ignored, this set assumes a lower block triangular form and can be solved directly by forward block substitution. As in each step of the finite-difference procedure a boundary value problem has to be solved for a non-homogeneous system of ordinary differential equations with space-dependent coefficients, application of any standard numerical procedure, for example, the finite-difference method or the method of adjoint equations, is too cumbersome and would make the whole procedure practically inapplicable. A simple and efficient approximation is proposed here, allowing analytical solution for the space dependence of the spherical-harmonics flux moments, and hence the derivation of the recurrence relations between the flux moments at successive lethargy pivotal points. According to the procedure indicated above a computer code has been developed for the CDC -3600 computer, which uses the KEDAK nuclear data file. The space and lethargy distribution of the resonance neutrons can be computed in such a detailed fashion as the neutron cross-sections are known for the reactor materials considered. The computing time is relatively short so that the code can be efficiently used, either autonomously, or as part of some complex modular scheme. Typical results will be presented and discussed in order to prove and illustrate the applicability of the

  5. Exact solutions of strong gravity in generalized metrics

    International Nuclear Information System (INIS)

    Hojman, R.; Smailagic, A.

    1981-05-01

    We consider classical solutions for the strong gravity theory of Salam and Strathdee in a wider class of metrics with positive, zero and negative curvature. It turns out that such solutions exist and their relevance for quark confinement is explored. Only metrics with positive curvature (spherical symmetry) give a confining potential in a simple picture of the scalar hadron. This supports the idea of describing the hadron as a closed microuniverse of the strong metric. (author)

  6. Soliton solutions of the two-dimensional KdV-Burgers equation by homotopy perturbation method

    International Nuclear Information System (INIS)

    Molabahrami, A.; Khani, F.; Hamedi-Nezhad, S.

    2007-01-01

    In this Letter, the He's homotopy perturbation method (HPM) to finding the soliton solutions of the two-dimensional Korteweg-de Vries Burgers' equation (tdKdVB) for the initial conditions was applied. Numerical solutions of the equation were obtained. The obtained solutions, in comparison with the exact solutions admit a remarkable accuracy. The results reveal that the HPM is very effective and simple

  7. Theory of quasi-Chaplygin unstable media and evolutionary principle for selecting spontaneous solutions

    International Nuclear Information System (INIS)

    Zhdanov, S.K.; Trubnikov, B.A.; Institut Atomnoi Energii, Moscow, USSR)

    1986-01-01

    A one-dimensional ideal gas with negative compressibility described by quasi-Chaplygin equations is discussed. Its reduction to a Laplace equation is shown, and an evolutionary principle for selecting spontaneous solutions is summarized. Three extremely simple spontaneous solutions are obtained along with multidimensional self-similar solutions. The Buneman instability in a plasma is considered as an example. 17 references

  8. Oxide nano-rod array structure via a simple metallurgical process

    International Nuclear Information System (INIS)

    Nanko, M; Do, D T M

    2011-01-01

    A simple method for fabricating oxide nano-rod array structure via metallurgical process is reported. Some dilute alloys such as Ni(Al) solid solution shows internal oxidation with rod-like oxide precipices during high-temperature oxidation with low oxygen partial pressure. By removing a metal part in internal oxidation zone, oxide nano-rod array structure can be developed on the surface of metallic components. In this report, Al 2 O 3 or NiAl 2 O 4 nano-rod array structures were prepared by using Ni(Al) solid solution. Effects of Cr addition into Ni(Al) solid solution on internal oxidation were also reported. Pack cementation process for aluminizing of Ni surface was applied to prepare nano-rod array components with desired shape. Near-net shape Ni components with oxide nano-rod array structure on their surface can be prepared by using the pack cementation process and internal oxidation,

  9. A variational solution of transport equation based on spherical geometry

    International Nuclear Information System (INIS)

    Liu Hui; Zhang Ben'ai

    2002-01-01

    A variational method with differential forms gives better precision for numerical solution of transport critical problem based on spherical geometry, and its computation seems simple than other approximate methods

  10. A simple computational for the analysis of 2-D solute migration experiments

    International Nuclear Information System (INIS)

    Villar, Heldio Pereira

    1996-01-01

    A preliminary model for the simulation of 2-D migration patterns is presented. This computer model adopts a novel approach to the solution of the advection-dispersion equation in two dimensions through finite differences. The soil column is divided into a number of thin columns. The 1-D advection-dispersion equation is applied in the direction of flow and, using the same time increment, the 1-D diffusion equation is applied perpendicularly to the flow. The results thus obtained were compared to those of two migration experiments with two different soils. (author)

  11. The GIS and data solution for advanced business analysis

    OpenAIRE

    RADUT Carmen

    2009-01-01

    The GIS Business Analyst is a suite of Geographic Information System (GIS)-enabled tools, wizards, and data that provides business professionals with a complete solution for site evaluation, selective customer profiling, and trade area market analysis. Running simple reports, mapping the results, and performing complex probability models are among the capabilities The GIS Business Analyst offers in one affordable desktop analysis solution. Data and analyses produced by The GIS Business Analys...

  12. Privacy Threats and Practical Solutions for Genetic Risk Tests

    OpenAIRE

    Barman, Ludovic; El Graini, Mohammed-Taha; Raisaro, Jean Louis; Ayday, Erman; Hubaux, Jean-Pierre

    2015-01-01

    Recently, several solutions have been proposed to address the complex challenge of protecting individuals’ genetic data during personalized medicine tests. In this short paper, we analyze different privacy threats and propose simple countermeasures for the generic architecture mainly used in the literature. In particular, we present and evaluate a new practical solution against a critical attack of a malicious medical center trying to actively infer raw genetic information of patients.

  13. Investigating student understanding of simple harmonic motion

    Science.gov (United States)

    Somroob, S.; Wattanakasiwich, P.

    2017-09-01

    This study aimed to investigate students’ understanding and develop instructional material on a topic of simple harmonic motion. Participants were 60 students taking a course on vibrations and wave and 46 students taking a course on Physics 2 and 28 students taking a course on Fundamental Physics 2 on the 2nd semester of an academic year 2016. A 16-question conceptual test and tutorial activities had been developed from previous research findings and evaluated by three physics experts in teaching mechanics before using in a real classroom. Data collection included both qualitative and quantitative methods. Item analysis and whole-test analysis were determined from student responses in the conceptual test. As results, most students had misconceptions about restoring force and they had problems connecting mathematical solutions to real motions, especially phase angle. Moreover, they had problems with interpreting mechanical energy from graphs and diagrams of the motion. These results were used to develop effective instructional materials to enhance student abilities in understanding simple harmonic motion in term of multiple representations.

  14. Simple types of anisotropic inflation

    International Nuclear Information System (INIS)

    Barrow, John D.; Hervik, Sigbjoern

    2010-01-01

    We display some simple cosmological solutions of gravity theories with quadratic Ricci curvature terms added to the Einstein-Hilbert Lagrangian which exhibit anisotropic inflation. The Hubble expansion rates are constant and unequal in three orthogonal directions. We describe the evolution of the simplest of these homogeneous and anisotropic cosmological models from its natural initial state and evaluate the deviations they will create from statistical isotropy in the fluctuations produced during a period of anisotropic inflation. The anisotropic inflation is not a late-time attractor in these models but the rate of approach to a final isotropic de Sitter state is slow and is conducive to the creation of observable anisotropic statistical effects in the microwave background. The statistical anisotropy would not be scale invariant and the level of statistical anisotropy will grow with scale.

  15. New knotted solutions of Maxwell's equations

    International Nuclear Information System (INIS)

    Hoyos, Carlos; Sircar, Nilanjan; Sonnenschein, Jacob

    2015-01-01

    In this paper we have further developed the study of topologically non-trivial solutions of vacuum electrodynamics. We have discovered a novel method of generating such solutions by applying conformal transformations with complex parameters on known solutions expressed in terms of Bateman's variables. This has enabled us to obtain a wide class of solutions from the basic configuration, such as constant electromagnetic fields and plane-waves. We have introduced a covariant formulation of Bateman's construction and discussed the conserved charges associated with the conformal group as well as a set of four types of conserved helicities. We have also given a formulation in terms of quaternions. This led to a simple map between the electromagnetic knotted and linked solutions into flat connections of SU(2) gauge theory. We have computed the corresponding Chern–Simons charge in a class of solutions and the charge takes integer values. (paper)

  16. The Point Zoro Symmetric Single-Step Procedure for Simultaneous Estimation of Polynomial Zeros

    Directory of Open Access Journals (Sweden)

    Mansor Monsi

    2012-01-01

    Full Text Available The point symmetric single step procedure PSS1 has R-order of convergence at least 3. This procedure is modified by adding another single-step, which is the third step in PSS1. This modified procedure is called the point zoro symmetric single-step PZSS1. It is proven that the R-order of convergence of PZSS1 is at least 4 which is higher than the R-order of convergence of PT1, PS1, and PSS1. Hence, computational time is reduced since this procedure is more efficient for bounding simple zeros simultaneously.

  17. Simple Planar Truss (Linear, Nonlinear and Stochastic Approach

    Directory of Open Access Journals (Sweden)

    Frydrýšek Karel

    2016-11-01

    Full Text Available This article deals with a simple planar and statically determinate pin-connected truss. It demonstrates the processes and methods of derivations and solutions according to 1st and 2nd order theories. The article applies linear and nonlinear approaches and their simplifications via a Maclaurin series. Programming connected with the stochastic Simulation-Based Reliability Method (i.e. the direct Monte Carlo approach is used to conduct a probabilistic reliability assessment (i.e. a calculation of the probability that plastic deformation will occur in members of the truss.

  18. Iterative and non-iterative solutions of engine flows using ASM and k-ε turbulence models

    International Nuclear Information System (INIS)

    Khaleghi, H.; Fallah, E.

    2003-01-01

    Various turbulent models are widely developed in order to make a good prediction of turbulence phenomena in different applications. The standard k-ε model shows a poor prediction for some applications. The Reynolds Stress Model (RSM) is expected to give a better prediction of turbulent characteristics, because a separate differential equation for each Reynolds stress component is solved in this model. In order to save both time and memory in this calculation a new Algebraic Stress Model (ASM) which was developed by Lumly et al in 1995 is used for calculations of flow characteristics in the internal combustion engine chamber. With using turbulent realizability principles, this model becomes a powerful and reliable turbulence model. In this paper the abilities of the model is examined in internal combustion engine flows. The results of ASM and k-ε models are compared with the experimental data. It is shown that the poor predictions of k-ε model are modified by ASM model. Also in this paper non-iterative PISO and iterative SIMPLE solution algorithms are compared. The results show that the PISO solution algorithm is the preferred and more efficient procedure in the calculation of internal combustion engine. (author)

  19. Construction and testing of simple airfoils to demonstrate structural design, materials choice, and composite concepts

    Science.gov (United States)

    Bunnell, L. Roy; Piippo, Steven W.

    1993-01-01

    The objective of this educational exercise is to have students build and evaluate simple wing structures, and in doing so, learn about materials choices and lightweight construction methods. A list of equipment and supplies and the procedure for the experiment are presented.

  20. Improved simple graphical solution for the eigenvalues of the finite square well potential

    International Nuclear Information System (INIS)

    Burge, E.J.

    1985-01-01

    The three principal graphical methods for obtaining the energy eigenvalues of the finite square well potential are presented. The forms of the wavefunctions within the well, and the corresponding linear probability densities, are derived directly from the method. A simple extension of the method allows the energy level spectrum to be obtained directly on a linear energy scale. The variations of the energy eigenvalues with well depth and width are separately and jointly displayed, and explicit corresponding functional relationships are derived. Two universal graphs are deduced which allow the rapid appreciation and calculation of the dependence of the energy levels on the depth and width of the well and on the mass of the particle. (author)

  1. New and highly efficient column chromatographic extraction and simple purification of camptothecin from Camptotheca acuminata and Nothapodytes pittosporoides.

    Science.gov (United States)

    Zeng, Xue-Hua; Li, Yue-Hong; Wu, Shan-Shan; Hao, Rui-Lin; Li, Hui; Ni, He; Han, Han-Bing; Li, Hai-Hang

    2013-01-01

    Camptothecin, a widely used natural anti-cancer drug, is difficult to extract and purify effectively from plants. To develop new and highly efficient extraction and purification methods for analysis and production of camptothecin from leaves and fruits of Camptotheca acuminata and Nothapodytes pittosporoides roots. Dried materials were loaded in empty columns with fivefold 60% ethanol for leaves or 70% ethanol for fruits of C. acumnata, and sixfold 70% ethanol for N. pittosporoides roots. The columns were eluted with the same solvents at room temperature. Eluent was collected as extraction solution. Extraction solution from leaves and fruits of C. acuminata was vacuum-evaporated to remove ethanol, precipitated at pH 8.0 to remove alkaline insolubles and fractionated with chloroform at pH 3.0, which yields a crude product with 70% purity. Extraction solution from N. pittosporoides roots was concentrated to 1/10 volume and precipitated at pH 3.0, which yields a crude product with 60% purity. All crude products were purified by crystallisation. All steps were monitored by HPLC. Camptothecin was extracted from the three plant materials at a 98% rate with 15- or 18-fold solvent for content analysis, or at a 97% rate with five- or sixfold solvent for production. All crude products were purified to 98%. The overall recovery rates of camptothecin from plant materials to purified products reached 92% or higher. The new procedures are simple and highly efficient, and have multiple advantages for quantitative analysis and large production of camptothecin from plants. Copyright © 2013 John Wiley & Sons, Ltd.

  2. The isolation of lutetium from gadolinium contained in Purex process solutions

    International Nuclear Information System (INIS)

    Bostick, D.T.; Vick, D.O.; May, M.P.; Walker, R.L.

    1992-09-01

    A chemical separation procedure has been devised to isolate Lu from Purex dissolver solutions containing the neutron poison, Gd. The isolation procedure involves the removal of U and >Pu from a dissolver solution using tributylphosphate solvent extraction. If required, solvent extraction using di-(2-ethylhexyl) phosphoric acid can be employed to further purify the sample be removing alkali and alkali earth elements. Finally, Lu is chromatographically separated from Gd and rare earth fission products on a Dowex 50W-X8 resin column using an alpha-hydroxyisobutyrate eluant. The success of the chemical separation procedure has been demonstrated in the quantitative recovery of as little as 1.4 ng Lu from solutions containing a 5000-fold excess of Gd. Additionally, Lu has been isolated from synthetic dissolver samples containing U, Ba, Cs, and Gd. Thermal emission MS data indicated that the Lu fraction of the synthetic sample was free of Gd interference

  3. Photochemical binding of photoallergens to human serum albumin: a simple in vitro method for screening potential photoallergens

    International Nuclear Information System (INIS)

    Barratt, M.D.; Brown, K.R.

    1985-01-01

    A simple procedure employing UV spectroscopy is described for testing the ability of chemicals to form covalent conjugates with proteins after irradiation with the appropriate wavelength of light. A range of known photoallergens of widely differing structure has been tested using this procedure; results of these experiments, together with evidence from the scientific literature, provide a correlation between compounds known to be photoallergens and their ability to form covalent conjugates with proteins on irradiation with the appropriate wavelength of light. The method is proposed as an in vitro screening procedure for potential photoallergens. (Auth.)

  4. A class of periodic solutions of nonlinear wave and evolution equations

    International Nuclear Information System (INIS)

    Kashcheev, V.N.

    1987-01-01

    For the case of 1+1 dimensions a new heuristic method is proposed for deriving dels-similar solutions to nonlinear autonomous differential equations. If the differential function f is a polynomial, then: (i) in the case of even derivatives in f the solution is the ratio of two polynomials from the Weierstrass elliptic functions; (ii) in the case of any order derivatives in f the solution is the ratio of two polynomials from simple exponents. Numerous examples are given constructing such periodic solutions to the wave and evolution equations

  5. [Preparation of sedation-analgesia procedures in spanish paediatric emergency departments: A descriptive study].

    Science.gov (United States)

    Míguez Navarro, Concepción; Oikonomopoulou, Niki; Lorente Romero, Jorge; Vázquez López, Paula

    2017-07-24

    The objective of this study was to describe the current practice regarding the preparation of the sedation-analgesia (SA) procedures performed in the paediatric emergency centres in Spain. A multicentre, observational and prospective analytical study was carried out on the SA procedures that were performed on children under 18 years-old in 18 paediatric emergency departments between February 2015 and January 2016. A total of 658 SA procedures were registered in 18 hospitals of Spain, most of them to children older than 24 months. The type of the procedure was: simple analgesia in 57 (8.6%), sedation in 44 (6.7%), SA for a not very painful procedure in 275 (41.8%), and SA for a very painful procedure in 282 (42.9%). Informed consent was requested in 98.6% of the cases. The written form was more frequently preferred in the group of patients that received SA for a very painful procedure (76.6%) in comparison to a painful procedure or to simple analgesia (62.9% and 54.4%, respectively, P<.001). The staff that most frequently performed the SA procedures were the paediatricians of the emergency departments (64.3%), followed by Paediatrics Residents (30.7%). The most frequent reasons for the SA were traumatological (35.9%) and surgical (28.4%). Fasting was observed in 81% of the cases. More than two-thirds (67.3%, n=480) children were monitored, the majority (95.8%) of them using pulse oximetry. The pharmacological strategy used was the administration of one drug in 443 (67.3%) of the cases, mostly nitrous oxide, and a combination of drugs in 215 (32.7%), especially midazolam/ketamine (46.9%). The majority of the SA procedures analysed in this study have been carried out correctly and prepared in accordance with the current guidelines. Copyright © 2017. Publicado por Elsevier España, S.L.U.

  6. Temporary solutions for a conservative estimation of void reactivity insertion in CANDU reactor

    International Nuclear Information System (INIS)

    Dumitrache, I.

    1997-01-01

    One of the most difficult task of the CANDU Reactor Physics Analysis is related to the correct treatment of the deviations from the reference coolant properties. The most significant problem is the reactivity inserted by a given coolant density variation. From the practical Nuclear Safety Analysis point of view, the solution must be not only conservative, but also adaptable to the current chain of codes utilized for accident simulation. The first set of experimental data was obtained by AECL many years ago. The fuel was fresh, clean and cold. Some of the currently used computer codes offer accurate predictions of the measured void reactivities. Unfortunately, the existing experimental data do not cover and are not significant for the burned CANDU fuel. A specific benchmark problem was suggested by the Institute for Nuclear Research (ICN) Pitesti. The problem was analysed and slightly modified during an IAEA Vienna RCM (Research Coordinating Meeting), Buenos Aires, 1990. Afterwards, the problem was independently solved in several countries, interested by the CANDU reactor. The results were presented and analysed at the Bombay RCM, 1992. It was clear that the interval defined by the code predictions is much too broad. New experimental data are necessary. They must cover the fuel isotopic composition specific for the burned CANDU fuel. The work is in progress at the Chalk River Laboratory. Temporary solutions have been analysed at the ICN Pitesti. The first aim was to identify the reactivity numerical values that are conservative, but not too inaccurate. The WIMS code predictions have been compared against other estimations, including the Monte-Carlo based ones. The second aim was to force the currently used code, PPV, to offer cell cross sections that are correct from the Reactor Physics point of view, and compatible with the imposed reactivity. Physical and mathematical procedures were proposed and evaluated. An additional solution was also taken into account: to

  7. Caffeine and Sugars Interact in Aqueous Solutions: A Simulation and NMR Study

    OpenAIRE

    Tavagnacco, Letizia; Engström, Olof; Schnupf, Udo; Saboungi, Marie-Louise; Himmel, Michael; Widmalm, Göran; Cesàro, Attilio; Brady, John W.

    2012-01-01

    Molecular dynamics simulations were carried out on several systems of caffeine interacting with simple sugars. These included a single caffeine molecule in a 3 molal solution of α-D-glucopyranose, at a caffeine concentration of 0.083 molal; a single caffeine in a 3 molal solution of β-D-glucopyranose, and a single caffeine molecule in a 1.08 molal solution of sucrose (table sugar). Parallel Nuclear Magnetic Resonance titration experiments were carried out on the same solutions under similar c...

  8. Is mammary reconstruction with the anatomical Becker expander a simple procedure? Complications and hidden problems leading to secondary surgical procedures: a follow-up study.

    Science.gov (United States)

    Farace, Francesco; Faenza, Mario; Bulla, Antonio; Rubino, Corrado; Campus, Gian Vittorio

    2013-06-01

    Debate over the role of Becker expander implants (BEIs) in breast reconstruction is still ongoing. There are no clear indications for BEI use. The main indications for BEI use are one-stage breast reconstruction procedure and congenital breast deformities correction, due to the postoperative ability to vary BEI volume. Recent studies showed that BEIs were removed 5 years after mammary reconstruction in 68% of operated patients. This entails a further surgical procedure. BEIs should not, therefore, be regarded as one-stage prostheses. We performed a case-series study of breast reconstructions with anatomically shaped Becker-35™ implants, in order to highlight complications and to flag unseen problems, which might entail a second surgical procedure. A total of 229 patients, reconstructed from 2005 to 2010, were enrolled in this study. Data relating to implant type, volume, mean operative time and complications were recorded. All the patients underwent the same surgical procedure. The minimum follow-up period was 18 months. During a 5-year follow-up, 99 patients required secondary surgery to correct their complications or sequelae; 46 of them underwent BEI removal within 2 years of implantation, 56 within 3 years, 65 within 4 years and 74 within 5 years. Our findings show that two different sorts of complications can arise with these devices, leading to premature implant removal, one common to any breast implant and one peculiar to BEIs. The Becker implant is a permanent expander. Surgeons must, therefore, be aware that, once positioned, the Becker expander cannot be adjusted at a later date, as in two-stage expander/prosthesis reconstructions for instance. Surgeons must have a clear understanding of possible BEI complications in order to be able to discuss these with their patients. Therefore, only surgeons experienced in breast reconstruction should use BEIs. Copyright © 2013 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by

  9. A mild and efficient procedure for the synthesis of ethers from various alkyl halides

    Directory of Open Access Journals (Sweden)

    Mosstafa Kazemi

    2013-10-01

    Full Text Available A simple, mild and practical procedure has been developed for the synthesis of symmetrical and unsymmetrical ethers by using DMSO, TBAI in the presence of K2CO3. We extended the utility of Potassium carbonate as an efficient base for the preparation of ethers. A wide range of alkyl aryl and dialkyl ethers are synthezied from treatment of aliphatic alcohols and phenols with various alkyl halides in the prescence of efficient base Potassium carbonate. Secondary alkyl halides were easily converted to corresponding ethers in releatively good yields . This is a mild, simple and practical procedure for the preparation of ethers in high yields and suitable times under mild condition.

  10. Simple Kidney Cysts

    Science.gov (United States)

    ... Solitary Kidney Your Kidneys & How They Work Simple Kidney Cysts What are simple kidney cysts? Simple kidney cysts are abnormal, fluid-filled ... that form in the kidneys. What are the kidneys and what do they do? The kidneys are ...

  11. Simultaneous contrast: evidence from licking microstructure and cross-solution comparisons.

    Science.gov (United States)

    Dwyer, Dominic M; Lydall, Emma S; Hayward, Andrew J

    2011-04-01

    The microstructure of rats' licking responses was analyzed to investigate both "classic" simultaneous contrast (e.g., Flaherty & Largen, 1975) and a novel discrete-trial contrast procedure where access to an 8% test solution of sucrose was preceded by a sample of either 2%, 8%, or 32% sucrose (Experiments 1 and 2, respectively). Consumption of a given concentration of sucrose was higher when consumed alongside a low rather than high concentration comparison solution (positive contrast) and consumption of a given concentration of sucrose was lower when consumed alongside a high rather than a low concentration comparison solution (negative contrast). Furthermore, positive contrast increased the size of lick clusters while negative contrast decreased the size of lick clusters. Lick cluster size has a positive monotonic relationship with the concentration of palatable solutions and so positive and negative contrasts produced changes in lick cluster size that were analogous to raising or lowering the concentration of the test solution respectively. Experiment 3 utilized the discrete-trial procedure and compared contrast between two solutions of the same type (sucrose-sucrose or maltodextrin-maltodextrin) or contrast across solutions (sucrose-maltodextrin or maltodextrin-sucrose). Contrast effects on consumption were present, but reduced in size, in the cross-solution conditions. Moreover, lick cluster sizes were not affected at all by cross-solution contrasts as they were by same-solution contrasts. These results are consistent with the idea that simultaneous contrast effects depend, at least partially, on sensory mechanisms.

  12. A simple and effective method to encapsulate tobacco mesophyll protoplasts to maintain cell viability

    Directory of Open Access Journals (Sweden)

    Rong Lei

    2015-01-01

    • It is very convenient to change or collect the solution without mechanically disturbing the protoplasts. This simple and effective silica sol–gel/alginate two-step immobilization of protoplasts in Transwell has great potential for applications in genetic transformation, metabolite production, and migration assays.

  13. Principles of Stagewise Separation Process Calculations: A Simple Algebraic Approach Using Solvent Extraction.

    Science.gov (United States)

    Crittenden, Barry D.

    1991-01-01

    A simple liquid-liquid equilibrium (LLE) system involving a constant partition coefficient based on solute ratios is used to develop an algebraic understanding of multistage contacting in a first-year separation processes course. This algebraic approach to the LLE system is shown to be operable for the introduction of graphical techniques…

  14. A simple model for determining photoelectron-generated radiation scaling laws

    International Nuclear Information System (INIS)

    Dipp, T.M.

    1993-12-01

    The generation of radiation via photoelectrons induced off of a conducting surface was explored using a simple model to determine fundamental scaling laws. The model is one-dimensional (small-spot) and uses monoenergetic, nonrelativistic photoelectrons emitted normal to the illuminated conducting surface. Simple steady-state radiation, frequency, and maximum orbital distance equations were derived using small-spot radiation equations, a sin 2 type modulation function, and simple photoelectron dynamics. The result is a system of equations for various scaling laws, which, along with model and user constraints, are simultaneously solved using techniques similar to linear programming. Typical conductors illuminated by low-power sources producing photons with energies less than 5.0 eV are readily modeled by this small-spot, steady-state analysis, which shows they generally produce low efficiency (η rsL -10.5 ) pure photoelectron-induced radiation. However, the small-spot theory predicts that the total conversion efficiency for incident photon power to photoelectron-induced radiated power can go higher than 10 -5.5 for typical real conductors if photons having energies of 15 eV and higher are used, and should go even higher still if the small-spot limit of this theory is exceeded as well. Overall, the simple theory equations, model constraint equations, and solution techniques presented provide a foundation for understanding, predicting, and optimizing the generated radiation, and the simple theory equations provide scaling laws to compare with computational and laboratory experimental data

  15. Fill rate estimation in periodic review policies with lost sales using simple methods

    Energy Technology Data Exchange (ETDEWEB)

    Cardós, M.; Guijarro Tarradellas, E.; Babiloni Griñón, E.

    2016-07-01

    Purpose: The exact estimation of the fill rate in the lost sales case is complex and time consuming. However, simple and suitable methods are needed for its estimation so that inventory managers could use them. Design/methodology/approach: Instead of trying to compute the fill rate in one step, this paper focuses first on estimating the probabilities of different on-hand stock levels so that the fill rate is computed later. Findings: As a result, the performance of a novel proposed method overcomes the other methods and is relatively simple to compute. Originality/value: Existing methods for estimating stock levels are examined, new procedures are proposed and their performance is assessed.

  16. A Simple Method for Automated Solid Phase Extraction of Water Samples for Immunological Analysis of Small Pollutants.

    Science.gov (United States)

    Heub, Sarah; Tscharner, Noe; Kehl, Florian; Dittrich, Petra S; Follonier, Stéphane; Barbe, Laurent

    2016-01-01

    A new method for solid phase extraction (SPE) of environmental water samples is proposed. The developed prototype is cost-efficient and user friendly, and enables to perform rapid, automated and simple SPE. The pre-concentrated solution is compatible with analysis by immunoassay, with a low organic solvent content. A method is described for the extraction and pre-concentration of natural hormone 17β-estradiol in 100 ml water samples. Reverse phase SPE is performed with octadecyl-silica sorbent and elution is done with 200 µl of methanol 50% v/v. Eluent is diluted by adding di-water to lower the amount of methanol. After preparing manually the SPE column, the overall procedure is performed automatically within 1 hr. At the end of the process, estradiol concentration is measured by using a commercial enzyme-linked immune-sorbent assay (ELISA). 100-fold pre-concentration is achieved and the methanol content in only 10% v/v. Full recoveries of the molecule are achieved with 1 ng/L spiked de-ionized and synthetic sea water samples.

  17. A Procedure for Modeling Photovoltaic Arrays under Any Configuration and Shading Conditions

    Directory of Open Access Journals (Sweden)

    Daniel Gonzalez Montoya

    2018-03-01

    Full Text Available Photovoltaic (PV arrays can be connected following regular or irregular connection patterns to form regular configurations (e.g., series-parallel, total cross-tied, bridge-linked, etc. or irregular configurations, respectively. Several reported works propose models for a single configuration; hence, making the evaluation of arrays with different configuration is a considerable time-consuming task. Moreover, if the PV array adopts an irregular configuration, the classical models cannot be used for its analysis. This paper proposes a modeling procedure for PV arrays connected in any configuration and operating under uniform or partial shading conditions. The procedure divides the array into smaller arrays, named sub-arrays, which can be independently solved. The modeling procedure selects the mesh current solution or the node voltage solution depending on the topology of each sub-array. Therefore, the proposed approach analyzes the PV array using the least number of nonlinear equations. The proposed solution is validated through simulation and experimental results, which demonstrate the proposed model capacity to reproduce the electrical behavior of PV arrays connected in any configuration.

  18. Buffered lidocaine and bupivacaine mixture - the ideal local anesthetic solution?

    Science.gov (United States)

    Best, Corliss A; Best, Alyssa A; Best, Timothy J; Hamilton, Danielle A

    2015-01-01

    The use of injectable local anesthetic solutions to facilitate pain-free surgery is an integral component of many procedures performed by the plastic surgeon. In many instances, a solution that has both rapid onset and prolonged duration of analgesia is optimal. A combination of lidocaine and bupivacaine, plain or with epinephrine, is readily available in most Canadian health care settings where such procedures are performed, and fulfills these criteria. However, commercially available solutions of both medications are acidic and cause a burning sensation on injection. Buffering to neutral pH with sodium bicarbonate is a practical method to mitigate the burning sensation, and has the added benefit of increasing the fraction of nonionized lipid soluble drug available. The authors report on the proportions of the three drugs to yield a neutral pH, and the results of an initial survey regarding the use of the combined solution with epinephrine in hand surgery.

  19. A 'simple' hybrid model for power derivatives

    International Nuclear Information System (INIS)

    Lyle, Matthew R.; Elliott, Robert J.

    2009-01-01

    This paper presents a method for valuing power derivatives using a supply-demand approach. Our method extends work in the field by incorporating randomness into the base load portion of the supply stack function and equating it with a noisy demand process. We obtain closed form solutions for European option prices written on average spot prices considering two different supply models: a mean-reverting model and a Markov chain model. The results are extensions of the classic Black-Scholes equation. The model provides a relatively simple approach to describe the complicated price behaviour observed in electricity spot markets and also allows for computationally efficient derivatives pricing. (author)

  20. Clarification of sodium silicate solutions derived from diatomites, to improve their industrial expectations

    International Nuclear Information System (INIS)

    Aguilar Cantillano, Eduardo

    2000-01-01

    solutions of soluble silicates synthesized have been clarified in Costa Rica from diatomite in almost 50% of their initial coloration. Clarification and removal of iron oxides have been achieved in a higher order of 50% m/m expressed as Fe 2 O 3 . Activated carbon treatment has clarified the scope of [31-57]%, but not significantly decreases the iron content. The application of NaClO to 3% m/m clarifies the scope of [28-51]%, and reduced iron by 48% m/m. The land alone has been shown that is not very effective filter to clarify, [0-14]%, but is effective for the stripping of iron by 68% m/m. Other procedures are effective in clarifying the scope of [42-51]% and reduced the amount of iron in the field of [48-66]%. The synthesis of soluble glasses is possible to clarify for conditioning with commercial purposes diverse, treatment methodologies and analytical control, simple and economical. (author) [es

  1. All solution-processed high-resolution bottom-contact transparent metal-oxide thin film transistors

    International Nuclear Information System (INIS)

    Park, Sung Kyu; Kim, Yong-Hoon; Han, Jeong-In

    2009-01-01

    We report all solution-processed high-resolution bottom-contact indium-gallium-zinc-oxide (IGZO) thin film transistors (TFTs) using a simple surface patterning and dip-casting process. High-resolution nanoparticulate Ag source/drain electrodes and a sol-gel processed IGZO semiconductor were deposited by a simple dip-casting along with a photoresist-free, non-relief-pattern lithographic process. The deposited Ag and IGZO solution can be steered into the desired hydrophilic areas by a low surface energy self-assembled monolayer, resulting in source/drain electrodes and semiconducting layer, respectively. The all solution-processed bottom-contact IGZO TFTs including a channel length of 10 μm typically showed a mobility range 0.05-0.2 cm 2 V -1 s -1 with an on/off ratio of more than 10 6 .

  2. SIMPLE METHOD FOR THE EXTRACTION OF PHOTOPIGMENTS AND MYCOSPORINE-LIKE AMINO ACIDS (MAAS) FROM SYMBIODINIUM SPP.

    Science.gov (United States)

    Numerous extraction methods have been developed and used in the quantitation of both photopigments and mycosporine amino acids (MAAs) found in Symbiodinium sp. and zooanthellate metazoans. We have development of a simple, mild extraction procedure using methanol, which when coupl...

  3. Analytical solution of strongly nonlinear Duffing oscillators

    Directory of Open Access Journals (Sweden)

    A.M. El-Naggar

    2016-06-01

    Full Text Available In this paper, a new perturbation technique is employed to solve strongly nonlinear Duffing oscillators, in which a new parameter α=α(ε is defined such that the value of α is always small regardless of the magnitude of the original parameter ε. Therefore, the strongly nonlinear Duffing oscillators with large parameter ε are transformed into a small parameter system with respect to α. Approximate solution obtained by the present method is compared with the solution of energy balance method, homotopy perturbation method, global error minimization method and lastly numerical solution. We observe from the results that this method is very simple, easy to apply, and gives a very good accuracy not only for small parameter εbut also for large values of ε.

  4. Improving the cleaning procedure to make kitchen floors less slippery.

    Science.gov (United States)

    Quirion, F; Poirier, P; Lehane, P

    2008-12-01

    This investigation shows that, in most cases, the floor cleaning procedure of typical restaurants could be improved, resulting in a better cleaning efficiency and a better floor friction. This simple approach could help reduce slips and falls in the workplace. Food safety officers visited ten European style restaurants in the London Borough of Bromley (UK) to identify their floor cleaning procedure in terms of the cleaning method, the concentration and type of floor cleaner and the temperature of the wash water. For all 10 restaurants visited, the cleaning method was damp mopping. Degreasers were used in three sites while neutral floor cleaners were used in seven sites. Typically, the degreasers were over diluted and the neutrals were overdosed. The wash water temperature ranged from 10 to 72 degrees C. The on-site cleaning procedures were repeated in the laboratory for the removal of olive oil from new and sealed quarry tiles, fouled and worn quarry tiles and new porcelain tiles. It is found that in 24 out of 30 cases, cleaning efficiency can be improved by simple changes in the floor cleaning procedure and that these changes result in a significant improvement of the floor friction. The nature of the improved floor cleaning procedure depends on the flooring type. New and properly sealed flooring tiles can be cleaned using damp mopping with a degreaser diluted as recommended by the manufacturer in warm or hot water (24 to 50 degrees C). But as the tiles become worn and fouled, a more aggressive floor cleaning is required such as two-step mopping with a degreaser diluted as recommended by the manufacturer in warm water (24 degrees C).

  5. Enzymatic reduction of 4-(dimethylamino)benzaldehyde with carrot bits (Daucus carota): a simple experiment for understanding biocatalysis; Reducao enzimatica do 4-(dimetilamino)benzaldeido com pedacos de cenoura (Daucus carota): um experimento simples na compreensao da biocatalise

    Energy Technology Data Exchange (ETDEWEB)

    Omori, Alvaro Takeo; Portas, Viviane Barbosa; Oliveira, Camila de Souza de, E-mail: alvaro.omori@ufabc.edu.br [Centro de Ciencias Naturais e Humanas, Universidade Federal do ABC, SP (Brazil)

    2012-07-01

    The present paper describes a simple, low-costly and environmentally friendly procedure for reduction of 4-(dimethylamino)benzaldehyde using carrot bits in water. This interdisciplinary experiment can be used to introduce the concepts of biocatalysis and green chemistry to undergraduate students. (author)

  6. Laparoscopic repair of perforated peptic ulcer: patch versus simple closure.

    Science.gov (United States)

    Abd Ellatif, M E; Salama, A F; Elezaby, A F; El-Kaffas, H F; Hassan, A; Magdy, A; Abdallah, E; El-Morsy, G

    2013-01-01

    Laparoscopic correction of perforated peptic ulcer (PPU) has become an accepted way of management. Patch omentoplasty stayed for decades the main method of repair. The goal of the present study was to evaluate whether laparoscopic simple repair of PPU is as safe as patch omentoplasty. Since June 2005, 179 consecutive patients of PPU were treated by laparoscopic repair at our centers. We conducted a retrospective chart review in December 2012. Group I (patch group) included patients who were treated with standard patch omentoplasty. Group II (non-patch group) included patients who received simple repair without patch. From June 2007 to Dec. 2012, 179 consecutive patients of PPU who were treated by laparoscopic repair at our centers were enrolled in this multi-center retrospective study. 108 patients belong to patch group. While 71 patients were treated with laparoscopic simple repair. Operative time was significantly shorter in group II (non patch) (p = 0.01). No patient was converted to laparotomy. There was no difference in age, gender, ASA score, surgical risk (Boey's) score, and incidence of co-morbidities. Both groups were comparable in terms of hospital stay, time to resume oral intake, postoperative complications and surgical outcomes. Laparoscopic simple repair of PPU is a safe procedure compared with the traditional patch omentoplasty in presence of certain selection criteria. Copyright © 2013 Surgical Associates Ltd. Published by Elsevier Ltd. All rights reserved.

  7. New LASER fluorometric HPLC detection for ortho-tyrosine in gamma-irradiated phenylalanine solution and pork

    International Nuclear Information System (INIS)

    Miyahara, Makoto; Toyoda, Masatake; Saito, Yukio; Nagasawa, Taeko; Izumi, Keiko; Kitamura, Mayumi

    1999-01-01

    New analytical procedure for o-tyrosine was studied to investigate effects of gamma irradiation on aqueous phenylalanine solution and pork. The process includes extraction and hydrolysis of protein, derivatization of the free amino acid by fluororeagent, and finally separation and detection by LASER fluorometric HPLC. The detection limit was 25ng. To study how the procedure works, irradiated phenylalanine solution and pork were analyzed. The samples were irradiated at doses up to 10 kGy at room temperature. Three tyrosine isomers were detected in phenylalanine solution, and 2 isomers (o-and p-tyrosine) were found in pork. Dose response was found in the formation of the isomers both in phenylalanine solution and in pork. O-tyrosine peak obtained from irradiated pork was separated from interference successfully. Those findings illustrate the procedure may be applicable to detection of irradiated food. (author)

  8. Knotted solutions for linear and nonlinear theories: Electromagnetism and fluid dynamics

    Directory of Open Access Journals (Sweden)

    Daniel W.F. Alves

    2017-10-01

    Full Text Available We examine knotted solutions, the most simple of which is the “Hopfion”, from the point of view of relations between electromagnetism and ideal fluid dynamics. A map between fluid dynamics and electromagnetism works for initial conditions or for linear perturbations, allowing us to find new knotted fluid solutions. Knotted solutions are also found to be solutions of nonlinear generalizations of electromagnetism, and of quantum-corrected actions for electromagnetism coupled to other modes. For null configurations, electromagnetism can be described as a null pressureless fluid, for which we can find solutions from the knotted solutions of electromagnetism. We also map them to solutions of Euler's equations, obtained from a type of nonrelativistic reduction of the relativistic fluid equations.

  9. How does the workload and work activities of procedural GPs compare to non-procedural GPs?

    Science.gov (United States)

    Russell, Deborah J; McGrail, Matthew R

    2017-08-01

    To investigate patterns of Australian GP procedural activity and associations with: geographical remoteness and population size hours worked in hospitals and in total; and availability for on-call DESIGN AND PARTICIPANTS: National annual panel survey (Medicine in Australia: Balancing Employment and Life) of Australian GPs, 2011-2013. Self-reported geographical work location, hours worked in different settings, and on-call availability per usual week, were analysed against GP procedural activity in anaesthetics, obstetrics, surgery or emergency medicine. Analysis of 9301 survey responses from 4638 individual GPs revealed significantly increased odds of GP procedural activity in anaesthetics, obstetrics or emergency medicine as geographical remoteness increased and community population size decreased, albeit with plateauing of the effect-size from medium-sized (population 5000-15 000) rural communities. After adjusting for confounders, procedural GPs work more hospital and more total hours each week than non-procedural GPs. In 2011 this equated to GPs practising anaesthetics, obstetrics, surgery, and emergency medicine providing 8% (95%CI 0, 16), 13% (95%CI 8, 19), 8% (95%CI 2, 15) and 18% (95%CI 13, 23) more total hours each week, respectively. The extra hours are attributable to longer hours worked in hospital settings, with no reduction in private consultation hours. Procedural GPs also carry a significantly higher burden of on-call. The longer working hours and higher on-call demands experienced by rural and remote procedural GPs demand improved solutions, such as changes to service delivery models, so that long-term procedural GP careers are increasingly attractive to current and aspiring rural GPs. © 2016 National Rural Health Alliance Inc.

  10. End-Member Formulation of Solid Solutions and Reactive Transport

    Energy Technology Data Exchange (ETDEWEB)

    Lichtner, Peter C. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2015-09-01

    A model for incorporating solid solutions into reactive transport equations is presented based on an end-member representation. Reactive transport equations are solved directly for the composition and bulk concentration of the solid solution. Reactions of a solid solution with an aqueous solution are formulated in terms of an overall stoichiometric reaction corresponding to a time-varying composition and exchange reactions, equivalent to reaction end-members. Reaction rates are treated kinetically using a transition state rate law for the overall reaction and a pseudo-kinetic rate law for exchange reactions. The composition of the solid solution at the onset of precipitation is assumed to correspond to the least soluble composition, equivalent to the composition at equilibrium. The stoichiometric saturation determines if the solid solution is super-saturated with respect to the aqueous solution. The method is implemented for a simple prototype batch reactor using Mathematica for a binary solid solution. Finally, the sensitivity of the results on the kinetic rate constant for a binary solid solution is investigated for reaction of an initially stoichiometric solid phase with an undersaturated aqueous solution.

  11. Cation exchange process for recovery of plutonium from laboratory solutions containing chloride

    International Nuclear Information System (INIS)

    Gray, L.W.

    1978-10-01

    A cation exchange technique was developed for the separation of plutonium from laboratory solutions containing either Pu(III) or Pu(III)--Pu(IV) mixtures in acidic solutions containing chloride ions. The procedure consists of adjusting the acid concentration to less than one molar and adjusting the valence of the plutonium ion to the (III) state, if necessary. The adjusted solution is fed to a cation exchange column and washed with distilled water to remove residual chlorides from the column. Plutonium is then eluted from the column with 5M nitric acid containing 0.34M sulfamic acid. This procedure was used to separate plutonium from 1.2M chloride solution on a production-scale column. Typical plutonium recovery was 99.97%, while greater than 96% of the original chloride was rejected

  12. Optimization of simulated moving bed (SMB) chromatography: a multi-level optimization procedure

    DEFF Research Database (Denmark)

    Jørgensen, Sten Bay; Lim, Young-il

    2004-01-01

    objective functions (productivity and desorbent consumption), employing the standing wave analysis, the true moving bed (TMB) model and the simulated moving bed (SMB) model. The procedure is constructed on a non-worse solution property advancing level by level and its solution does not mean a global optimum...

  13. Recursive solution for dynamic response of one-dimensional structures with time-dependent boundary conditions

    Energy Technology Data Exchange (ETDEWEB)

    Abadi, Mohammad Tahaye [Aerospace Research Institute, Tehran (Iran, Islamic Republic of)

    2015-10-15

    A recursive solution method is derived for the transient response of one-dimensional structures subjected to the general form of time dependent boundary conditions. Unlike previous solution methods that assumed the separation of variables, the present method involves formulating and solving the dynamic problems using the summation of two single-argument functions satisfying the motion equation. Based on boundary and initial conditions, a recursive procedure is derived to determine the single-argument functions. Such a procedure is applied to the general form of boundary conditions, and an analytical solution is derived by solving the recursive equation. The present solution method is implemented for base excitation problems, and the results are compared with those of the previous analytical solution and the Finite element (FE) analysis. The FE results converge to the present analytical solution, although considerable error is found in predicting a solution method on the basis of the separation of variables. The present analytical solution predicts the transient response for wave propagation problems in broadband excitation frequencies.

  14. Recursive solution for dynamic response of one-dimensional structures with time-dependent boundary conditions

    International Nuclear Information System (INIS)

    Abadi, Mohammad Tahaye

    2015-01-01

    A recursive solution method is derived for the transient response of one-dimensional structures subjected to the general form of time dependent boundary conditions. Unlike previous solution methods that assumed the separation of variables, the present method involves formulating and solving the dynamic problems using the summation of two single-argument functions satisfying the motion equation. Based on boundary and initial conditions, a recursive procedure is derived to determine the single-argument functions. Such a procedure is applied to the general form of boundary conditions, and an analytical solution is derived by solving the recursive equation. The present solution method is implemented for base excitation problems, and the results are compared with those of the previous analytical solution and the Finite element (FE) analysis. The FE results converge to the present analytical solution, although considerable error is found in predicting a solution method on the basis of the separation of variables. The present analytical solution predicts the transient response for wave propagation problems in broadband excitation frequencies.

  15. Evaluation of Oral and Maxillofacial Surgery Residents' Operative Skills: Feasibility and Engagement Study Using SIMPL Software for a Mobile Phone.

    Science.gov (United States)

    Kaban, Leonard B; Cappetta, Alyssa; George, Brian C; Lahey, Edward T; Bohnen, Jordan D; Troulis, Maria J

    2017-10-01

    There are no universally accepted tools to evaluate operative skills of surgical residents in a timely fashion. The purpose of this study was to determine the feasibility of using a smartphone application, SIMPL (System for Improving and Measuring Procedural Learning), developed by a multi-institutional research collaborative, to achieve a high rate of timely operative evaluations and resident communication and to collect performance data. The authors hypothesized that these goals would be achieved because the process is convenient and efficient. This was a prospective feasibility and engagement study using SIMPL to evaluate residents' operative skills. SIMPL requires the attending surgeon to answer 3 multiple-choice questions: 1) What level of help (Zwisch Scale) was required by the trainee? 2) What was the level of performance? 3) How complex was the case? The evaluator also can dictate a narrative. The sample was composed of 3 faculty members and 3 volunteer senior residents. Predictor variables were the surgeons, trainees, and procedures performed. Outcome variables included number and percentage of procedures performed by faculty-and-resident pairs assessed, time required to complete assessments, time lapsed to submission, percentage of assessments with narratives, and residents' response rates. From March through June 2016, 151 procedures were performed in the operating room by the faculty-and-resident teams. There were 107 assessments submitted (71%). Resident response (self-assessment) to faculty evaluations was 81%. Recorded time to complete assessments (n = 75 of 107) was shorter than 2 minutes. The time lapsed to submission was shorter than 72 hours (100%). Dictations were submitted for 35 evaluations (33%). Data for the type of help, performance, and complexity of cases were collected for each resident. SIMPL facilitates timely intraoperative evaluations of surgical skills, engagement by faculty and residents, and collection of detailed procedural

  16. A Simple Method for Removal of Particles from the Retinal Surface during Vitrectomy

    Directory of Open Access Journals (Sweden)

    Touka Banaee

    2014-01-01

    Full Text Available Removal of particulate materials from the retinal surface is somewhat difficult during small gauge vitrectomy. Simple injection of balanced salt solution into the vitreous cavity in a controlled manner using a connector tubing between the syringe and needle can produce enough turbulence to float the deposited material and remove it.

  17. Analytical solution and simplified analysis of coupled parent-daughter steady-state transport with multirate mass transfer

    Science.gov (United States)

    R. Haggerty

    2013-01-01

    In this technical note, a steady-state analytical solution of concentrations of a parent solute reacting to a daughter solute, both of which are undergoing transport and multirate mass transfer, is presented. Although the governing equations are complicated, the resulting solution can be expressed in simple terms. A function of the ratio of concentrations, In (daughter...

  18. A Survey of Procedural Methods for Terrain Modelling

    NARCIS (Netherlands)

    Smelik, R.M.; Kraker, J.K. de; Groenewegen, S.A.; Tutenel, T.; Bidarra, R.

    2009-01-01

    Procedural methods are a promising but underused alternative to manual content creation. Commonly heard drawbacks are the randomness of and the lack of control over the output and the absence of integrated solutions, although more recent publications increasingly address these issues. This paper

  19. A Simple Sag Generator Using SSRs

    DEFF Research Database (Denmark)

    Senturk, Osman Selcuk; Hava, Ahmet M.

    2010-01-01

    conditions (critical loads) and this property often may not be accommodated inside the device itself and sag compensating power conditioners have been developed for such purposes. While in practice voltage sags are not wanted, generating sags becomes necessary for the purpose of experimentally verifying...... the performances of the equipment (both the equipment under sag condition and the sag compensating power conditioner) under sag conditions. In this work, a simple and economical, yet highly performing sag generator is developed, its design discussed, and its feasibility demonstrated by experiments. The proposed...... is evaluated and finally the utilization of the sag generator in the test of a series active filter based power quality conditioner is demonstrated. The proposed approach provides an effective solution for voltage sag generation....

  20. A simple three dimensional wide-angle beam propagation method

    Science.gov (United States)

    Ma, Changbao; van Keuren, Edward

    2006-05-01

    The development of three dimensional (3-D) waveguide structures for chip scale planar lightwave circuits (PLCs) is hampered by the lack of effective 3-D wide-angle (WA) beam propagation methods (BPMs). We present a simple 3-D wide-angle beam propagation method (WA-BPM) using Hoekstra’s scheme along with a new 3-D wave equation splitting method. The applicability, accuracy and effectiveness of our method are demonstrated by applying it to simulations of wide-angle beam propagation and comparing them with analytical solutions.