  1. Solar collector manufacturing activity, 1990

    International Nuclear Information System (INIS)

    1992-01-01

    The Solar Collector Manufacturing Activity 1990 report prepared by the Energy Information Administration (EIA) presents summary and detailed data provided by domestic manufacturers on shipments of solar thermal collectors and photovoltaic cells and modules. Summary data on solar thermal collector shipments are presented for the period 1974 through 1990. Summary data on photovoltaic cell and module shipments are presented for the period 1982 through 1990. Detailed information for solar thermal collectors and photovoltaic cells and modules are presented for 1990

  2. Testing of PCM Heat Storage Modules with Solar Collectors as Heat Source

    DEFF Research Database (Denmark)

    Englmair, Gerald; Dannemand, Mark; Johansen, Jakob Berg

    2016-01-01

    was to actively utilize the ability of the material to supercool to obtain long storage periods. The modules were charged with solar heat supplied by 22.4 m2 evacuated tubular collectors. The investigation showed that it was possible to fully charge one module within a period of 270 minutes with clear skies...

  3. Solar collector overheating protection

    NARCIS (Netherlands)

    Slaman, M.J.; Griessen, R.P.

    Prismatic structures in a thermal solar collector are used as overheating protection. Such structures reflect incoming light efficiently back whenever less thermal power is extracted from the solar collector. Maximum thermal power is generated when the prismatic structure is surrounded by a

  4. Solar energy collector

    Science.gov (United States)

    Brin, Raymond L.; Pace, Thomas L.

    1978-01-01

    The invention relates to a solar energy collector comprising solar energy absorbing material within chamber having a transparent wall, solar energy being transmitted through the transparent wall, and efficiently absorbed by the absorbing material, for transfer to a heat transfer fluid. The solar energy absorbing material, of generally foraminous nature, absorbs and transmits the solar energy with improved efficiency.

  5. Solar collector array

    Science.gov (United States)

    Hall, John Champlin; Martins, Guy Lawrence

    2015-09-06

    A method and apparatus for efficient manufacture, assembly and production of solar energy. In one aspect, the apparatus may include a number of modular solar receiver assemblies that may be separately manufactured, assembled and individually inserted into a solar collector array housing shaped to receive a plurality of solar receivers. The housing may include optical elements for focusing light onto the individual receivers, and a circuit for electrically connecting the solar receivers.

  6. Thermal Efficiency of Power Module “Boiler with Solar Collectors as Additional Heat Source” For Combined Heat Supply System

    Directory of Open Access Journals (Sweden)

    Denysova A.E.

    2015-04-01

    Full Text Available The purpose of work is to increase the efficiency of the combined heat supply system with solar collectors as additional thermal generators. In order to optimize the parameters of combined heat supply system the mathematical modeling of thermal processes in multi module solar collectors as additional thermal generators for preheating of the water for boiler have been done. The method of calculation of multi-module solar collectors working with forced circulation for various configurations of hydraulic connection of solar collector modules as the new result of our work have been proposed. The results of numerical simulation of thermal efficiency of solar heat source for boiler of combined heat supply system with the account of design features of the circuit; regime parameters of thermal generators that allow establishing rational conditions of its functioning have been worked out. The conditions of functioning that provide required temperature of heat carrier incoming to boiler and value of flow rate at which the slippage of heat carrier is not possible for different hydraulic circuits of solar modules have been established.

  7. Solar collector. Solarkollektor

    Energy Technology Data Exchange (ETDEWEB)

    1985-08-14

    The purpose of the invention is to design the support of a mirror for focussing the sun's light on to the absorber (flat solar collectors), so that no distortion of the mirrors can occur due to the fixing or due to thermal stresses in this support system. According to the invention, this problem is solved by the use of a mirror curved on one axis, which is chamfered in the longitudinal direction parallel to the bending edges and is provided with metal supports. This configuration achieves safe operation of the mirror, free of distortion, and easy replaceability of the mirror. Design and material details of this solar collector mirror device are described in 3 patent claims. (HWJ).

  8. EFFICIENCY OF MULTI-MODULE SOLAR COLLECTORS AS A PREFIX TO A BOILER

    Directory of Open Access Journals (Sweden)

    Denysova A.E.

    2014-12-01

    Full Text Available Influencing factors on thermal and economic efficiency of the combined of heat supply installation are established. Constructive circuits of solar heat supply "prefix" interaction with boiler installation are worked out. Mathematical models of heat exchange processes in elements of combined heat supply system with the account solar engineering characteristics are developed. The techniques of analysis of efficiency of multi-modular system of solar collectors with compulsory circulation for water heating boiler allowing calculating of efficiency factor; heat removal factor and heat transfer factor with the account of construction and operation conditions of alternative heat supply system are presented.

  9. Tracking system for solar collectors

    Science.gov (United States)

    Butler, B.

    1980-10-01

    A tracking system is provided for pivotally mounted spaced-apart solar collectors. A pair of cables is connected to spaced-apart portions of each collector, and a driver displaces the cables, thereby causing the collectors to pivot about their mounting, so as to assume the desired orientation. The collectors may be of the cylindrical type as well as the flat-plate type. Rigid spar-like linkages may be substituted for the cables. Releasable attachments of the cables to the collectors is also described, as is a fine tuning mechanism for precisely aligning each individual collector.

  10. Adsorptive refrigeration system using a solar collector with a thermal insulating module; Sistema de refrigeracao adsortivo com a utilizacao de um coletor solar com anteparo otico

    Energy Technology Data Exchange (ETDEWEB)

    Gurgel, Jose Mauricio [Paraiba Univ., Joao Pessoa, PB (Brazil). Laboratorio de Energia Solar]. E-mail: gurgel@les.ufpb.br; Espinola Junior, Jose [Paraiba Univ., Joao Pessoa, PB (Brazil). Curso de Pos-Graduacao em Engenharia Mecanica; Andrade Filho, Luiz Simao [Paraiba Univ., Joao Pessoa, PB (Brazil). Centro de Tecnologia. Dept. de Tecnologia da Construcao Civil; Marcondes, Francisco [Paraiba Univ., Joao Pessoa, PB (Brazil). Escola de Engenharia. Dept. de Engenharia Mecanica

    2000-07-01

    The use of a solid adsorption cooling unit based on the binary silica gel/water couple constitute an very promising way to harness solar energy refrigeration purposes. Here is presented a mathematical model for the simulation of the system under several use conditions and it was shown coherent when compared with some experimental results. The several accomplished simulations showed the need to be projected a modulate reactor that can offer cooling easiness during the night period and shown the advantage of the use of an solar collector that can be easily opened and your thermal insulating module placed across the glass close the thermal radiation when the desorption process finish. The simulations results presented here shown an better COP for this configuration through an better cooling of the collector at night. (author)

  11. Turning collectors for solar radiation

    Science.gov (United States)

    Barak, Amitzur Z.

    1976-01-01

    A device is provided for turning a solar collector about the polar axis so that the collector is directed toward the sun as the sun tracks the sky each day. It includes two heat-expansive elements and a shadow plate. In the morning a first expansive element is heated, expands to turn the collector to face the sun, while the second expansive element is shaded by the plate. In the afternoon the second element is heated, expands to turn the collector to face the sun, while the first is shaded by the plate.

  12. Thin film solar energy collector

    Science.gov (United States)

    Aykan, Kamran; Farrauto, Robert J.; Jefferson, Clinton F.; Lanam, Richard D.

    1983-11-22

    A multi-layer solar energy collector of improved stability comprising: (1) a substrate of quartz, silicate glass, stainless steel or aluminum-containing ferritic alloy; (2) a solar absorptive layer comprising silver, copper oxide, rhodium/rhodium oxide and 0-15% by weight of platinum; (3) an interlayer comprising silver or silver/platinum; and (4) an optional external anti-reflective coating, plus a method for preparing a thermally stable multi-layered solar collector, in which the absorptive layer is undercoated with a thin film of silver or silver/platinum to obtain an improved conductor-dielectric tandem.

  13. Accelerated Testing of Solar Collector Durability

    DEFF Research Database (Denmark)

    Svendsen, Sv Aa Højgaard

    1996-01-01

    A climatic simulator has been build to test the reliability and durability of solar collectors. In the climatic simulator the collector is expåosed to extreme climatic conditions and temperature variations in an accelerated way and during this process the function of the collector is tested and t...... and the microclimate in the collector box is measured....

  14. Studies of flat-plate solar air collectors with absorber plates made of amorphous silicon photovoltaic modules; Amorphous taiyo denchi module wo shunetsuban to shita heibangata kukishiki shunetsuki no kenkyu

    Energy Technology Data Exchange (ETDEWEB)

    Sato, K.; Ito, S.; Miura, N. [Kanagawa Institute of Technology, Kanagawa (Japan)

    1996-10-27

    A light/heat hybrid air type heat collector has been developed in which heat is collected by solar cell panels. In Type 1 heat collector provided with a glass cover, two modules are connected in series and placed under a glass cover to serve as a heat collecting plate, each module built of a steel plate and two thin-film amorphous solar cells bonded to the steel plate. Air runs under the heat collecting plate. Type 2 heat collector is a Type 1 heat collector minus the glass cover. Air is taken in by a fan, runs in a vinyl chloride tube, and then through the heat collector where it is heated by the sun, and goes out at the exit. Heat collecting performance was subjected to theoretical analysis. This heat collector approximated in point of heat collection a model using a board painted black, which means that the new type functions effectively as an air-type heat collector. Operating as a photovoltaic power generator, the covered type generated approximately 20% less than the uncovered type under 800W/m{sup 2} insolation conditions. Type 1 has been in service for five months, and Type 2 for 2 months. At present, both are free of troubles such as deformation and the amorphous solar cell modules have deteriorated but a little. 4 refs., 9 figs.

  15. Installation package for concentrating solar collector panels

    Science.gov (United States)

    1978-01-01

    The concentrating solar collector panels comprise a complete package array consisting of collector panels using modified Fresnel prismatic lenses for a 10 to 1 concentrating ratio, supporting framework, fluid manifolding and tracking drive system, and unassembled components for field erection.

  16. Design package for concentrating solar collector panels

    Energy Technology Data Exchange (ETDEWEB)

    1978-08-01

    Information used to evaluate the design of the Northrup concentrating collector is presented. Included are the system performance specifications, the applications manual, and the detailed design drawings of the collector. The Northrup concentrating solar collector is a water/glycol/working fluid type, dipped galvanized steel housing, transparent acrylic Fresnel lens cover, copper absorber tube, fiber glass insulation and weighs 98 pounds. The gross collector area is about 29.4/sup 2/ per collector. A collector assembly includes four collector units within a tracking mount array.

  17. Theoretical and experimental investigations of Chinese evacuated tubular solar collectors

    DEFF Research Database (Denmark)

    Qin, Lin; Furbo, Simon

    1999-01-01

    Four different marketed Chinese evacuated tubular solar collectors have been investigated both theoretically and experimentally. The advantages of the investigated solar collectors compared to normal flat plate collectors were elucidated.......Four different marketed Chinese evacuated tubular solar collectors have been investigated both theoretically and experimentally. The advantages of the investigated solar collectors compared to normal flat plate collectors were elucidated....

  18. Alignment method for solar collector arrays

    Science.gov (United States)

    Driver, Jr., Richard B

    2012-10-23

    The present invention is directed to an improved method for establishing camera fixture location for aligning mirrors on a solar collector array (SCA) comprising multiple mirror modules. The method aligns the mirrors on a module by comparing the location of the receiver image in photographs with the predicted theoretical receiver image location. To accurately align an entire SCA, a common reference is used for all of the individual module images within the SCA. The improved method can use relative pixel location information in digital photographs along with alignment fixture inclinometer data to calculate relative locations of the fixture between modules. The absolute locations are determined by minimizing alignment asymmetry for the SCA. The method inherently aligns all of the mirrors in an SCA to the receiver, even with receiver position and module-to-module alignment errors.

  19. Exergy analysis of photovoltaic solar collector

    International Nuclear Information System (INIS)

    Sopian, K.; Othman, M.Y.Hj.

    1998-01-01

    The exergy analysis (availability or second law analysis) is applied to the photovoltaic thermal solar collector. Photovoltaic thermal collector is a special type of solar collector where electricity and heat are produced simultaneously. The electricity produced from the photovoltaic thermal collector is all converted into useful work. The available quantity of the heat collected can readily be determined by taking into account both the quantity (heat quantity) and quality ( a function of temperature) of the thermal energy. Therefore, using the concept of exergy allows heat produced from the thermal collector and the electricity generated from the photovoltaic cells to be compared or to be evaluated on the basis of a common measure such as the effectiveness on solar energy collection or the total amount of available energy. In this paper, the effectiveness of solar energy collection is called combined photovoltaic thermal exergy efficiency. An experimental setup of a double pas photovoltaic thermal solar collector has been deigned, fabricated and tested. (author)

  20. Drying by means of solar collectors

    Energy Technology Data Exchange (ETDEWEB)

    Nydegger, F.; Klaeger, P.

    1983-01-01

    Solar collectors may be covered with either transparent plastic plates or dark Eternit, or else black sheet metal. Evaluation of 57 solar collectors showed that collector surface averages 202 m/sup 2/ (70 - 460 m/sup 2/). The ratio between hay born surface and collector surface is 1 : 1.8 with polyester and 1 : 2.4 with Eternit roofs. Prices for collectors range between 30 and 35 Swiss Francs/sqm with roof-integrated facilities and c. 50 Swiss Francs/sqm with on-roof constructions. Sheet metal and Eternit converings are cheaper than polyester. Out of the total of solar collectors studied one did not meet the expectations, two facilities just fell short of them, 28 fulfilled them and 23 exceeded tham. Dust depositing and condensation water formation posed some problems.

  1. PERFORMANCE EVALUATION OF SOLAR COLLECTORS USING A SOLAR SIMULATOR

    Directory of Open Access Journals (Sweden)

    M. Norhafana

    2015-11-01

    Full Text Available Solar water heating systems is one of the applications of solar energy. One of the components of a solar water heating system is a solar collector that consists of an absorber. The performance of the solar water heating system depends on the absorber in the solar collector. In countries with unsuitable weather conditions, the indoor testing of solar collectors with the use of a solar simulator is preferred. Thus, this study is conducted to use a multilayered absorber in the solar collector of a solar water heating system as well as to evaluate the performance of the solar collector in terms of useful heat of the multilayered absorber using the multidirectional ability of a solar simulator at several values of solar radiation. It is operated at three variables of solar radiation of 400 W/m2, 550 W/m2 and 700 W/m2 and using three different positions of angles at 0º, 45º and 90º. The results show that the multilayer absorber in the solar collector is only able to best adapt at 45° of solar simulator with different values of radiation intensity. At this angle the maximum values of useful heat and temperature difference are achieved. KEYWORDS: solar water heating system; solar collector; multilayered absorber; solar simulator; solar radiation 

  2. Solar Heating Systems with Evacuated Tubular Solar Collector

    DEFF Research Database (Denmark)

    Qin, Lin; Furbo, Simon

    1998-01-01

    Recently different designed evacuated tubular solar collectors were introduced on the market by different Chinese companies. In the present study, investigations on the performance of four different Chinese evacuated tubular collectors and of solar heating systems using these collectors were...... carried out, employing both laboratory test and theoretical calculations. The collectors were tested in a small solar domestic hot water (SDHW) system in a laboratory test facility under realistic conditions. The yearly thermal performance of solar heating systems with these evacuated tubular collectors......, as well as with normal flat-plate collectors was calculated under Danish weather conditions. It is found that, for small SDHW systems with a combi tank design, an increase of 25% -55% net utilized solar energy can be achieved by using these evacuated tubular collectors instead of normal flat...

  3. Investigations on efficiencies of HT solar collectors for different flow rates and collector tilts

    DEFF Research Database (Denmark)

    Chen, Ziqian; Perers, Bengt; Furbo, Simon

    2013-01-01

    Two HT solar collectors for solar heating plants from Arcon Solvarme A/S are tested in a laboratory test facility for solar collectors at Technical University of Denmark (DTU). The collectors are designed in the same way. However, one solar collector is equipped with an ETFE foil between the abso......Two HT solar collectors for solar heating plants from Arcon Solvarme A/S are tested in a laboratory test facility for solar collectors at Technical University of Denmark (DTU). The collectors are designed in the same way. However, one solar collector is equipped with an ETFE foil between...... the absorber and the cover glass and the other is without ETFE foil. The efficiencies for the collectors are tested at different flow rates and tilt. On the basis of the measured efficiencies, the efficiencies for the collectors as functions of flow rates are obtained. The calculated efficiencies are in good...

  4. COMPARATIVE FIELD EXPERIMENTAL INVESTIGATIONS OF DIFFERENT FLAT PLATE SOLAR COLLECTORS

    Directory of Open Access Journals (Sweden)

    Guangming Chen

    2015-12-01

    Full Text Available Full-scale traditional metal solar collectors and solar collector specimens fabricated from polymeric materials were investigated in the present study. A polymeric collector is 67.8% lighter than a traditional metal solar collector, and a metal solar collector with transparent plastic covering is 40.3% lighter than a traditional metal solar collector. Honeycomb multichannel plates made from polycarbonate were chosen to create a polymeric solar collector. A test rig for the natural circulation of the working fluid in a solar collector was built for a comparative experimental investigation of various solar collectors operating at ambient conditions. It was shown experimentally that the efficiency of a polymeric collector is 8–15% lower than the efficiency of a traditional collector.

  5. Optimum solar collector fluid flow rates

    DEFF Research Database (Denmark)

    Furbo, Simon; Shah, Louise Jivan

    1996-01-01

    Experiments showed that by means of a standard electronically controlled pump, type UPE 2000 from Grundfos it is possible to control the flow rate in a solar collector loop in such a way that the flow rate is strongly influenced by the temperature of the solar collector fluid passing the pump....... The flow rate is increasing for increasing temperature.The flow rate at the high temperature level is typically 70 % greater than the flow rate at the low temperature level.Further, the energy consumption for the electronically controlled pump in a solar heating system will be somewhat smaller than...... the energy consumption of a normal ciculation pump in the solar heating system.Calculations showed that the highest thermal performances for small SDHW systems based on mantle tanks with constant volume flow rates in the solar collector loops are achieved if the flow rate is situated in the interval from 0...

  6. A diagram for defined flat plate solar collector area for solar floor heating

    Energy Technology Data Exchange (ETDEWEB)

    Altuntop, N.; Tekin, Y. [Erciyes University, Dept. of Mechanical Engineering (Turkey); Cengel, Y.A. [Nevada Reno University, Dept. of Mechanical Engineering, NV (United States)

    2000-07-01

    In winters, one of the best ways to heat living areas by using the low- temperature - water obtained from flat-plate solar collectors is the floor heating. In floor heating, low temperature-water (30 + 60 deg C) can be used and heat can be stored in water when solar radiation is not possible. In this study, it is aimed to define collector surface needed to supply heat for floor heating. It is also aimed to define and explain the diagram developed for every heating months. The calculations about the sun geometry are used to define the amount of radiation coming in to the collectors. Formulations are made about the definition of solar radiation absorbed by the collectors, the total heat loss coefficient, and the collector plate surface temperature. These formulations are transformed in to the diagram. In addition, the studies, heat transfer calculations and design parameters about the floor of the heating areas are used. A combined collector floor heating diagram is obtained. This diagram is used to define collector surface area necessary to supply heat for floor heated places. In this diagram, the collector surface area is obtained by giving the heat capacity of the place area, floor surface temperature, approximate modulation distance of the floor, the elevation of city, collector slope angle, wind speed, sun shine lime and the amount of the solar radiation obtained from the solar radiation diagram. (authors)

  7. Next Generation Solar Collectors for CSP

    Energy Technology Data Exchange (ETDEWEB)

    Molnar, Attila [3M Company, St. Paul, MN (United States); Charles, Ruth [3M Company, St. Paul, MN (United States)

    2014-07-31

    The intent of “Next Generation Solar Collectors for CSP” program was to develop key technology elements for collectors in Phase 1 (Budget Period 1), design these elements in Phase 2 (Budget Period 2) and to deploy and test the final collector in Phase 3 (Budget Period 3). 3M and DOE mutually agreed to terminate the program at the end of Budget Period 1, primarily due to timeline issues. However, significant advancements were achieved in developing a next generation reflective material and panel that has the potential to significantly improve the efficiency of CSP systems.

  8. Short-Term Solar Collector Power Forecasting

    DEFF Research Database (Denmark)

    Bacher, Peder; Madsen, Henrik; Perers, Bengt

    2011-01-01

    This paper describes a new approach to online forecasting of power output from solar thermal collectors. The method is suited for online forecasting in many applications and in this paper it is applied to predict hourly values of power from a standard single glazed large area flat plate collector....... The method is applied for horizons of up to 42 hours. Solar heating systems naturally come with a hot water tank, which can be utilized for energy storage also for other energy sources. Thereby such systems can become an important part of energy systems with a large share of uncontrollable energy sources......-adaptive linear models. The approach is similar to the one by Bacher et al. (2009), but contains additional effects due to differences between solar thermal collectors and photovoltaics. Numerical weather predictions provided by Danish Meteorological Institute are used as input. The applied models adapt over time...

  9. Qualification test and analysis report: solar collectors

    Energy Technology Data Exchange (ETDEWEB)

    1978-12-01

    Test results show that the Owens-Illinois Sunpak/sup TM/ Model SEC 601 air-cooled collector meets the national standards and codes as defined in the Subsystem Performance Specification and Verification Plan of NASA/MSFC Contract NAS8-32259, dated October 28, 1976. The architectural and engineering firm of Smith, Hinchman and Grylls, Detroit, Michigan, acted in the capacity of the independent certification agency. The program calls for the development, fabrication, qualification and delivery of an air-liquid solar collector for solar heating, combined heating and cooling, and/or hot water systems.

  10. Two-axis movable concentrating solar energy collector

    Science.gov (United States)

    Perkins, G. S.

    1977-01-01

    Proposed solar-tracker collector assembly with boiler in fixed position, allows use of hard line connections, capable of withstanding optimum high temperature fluid flow. System thereby eliminates need for flexible or slip connection previously used with solar collector systems.

  11. Behavior of a solar collector loop during stagnation

    DEFF Research Database (Denmark)

    Chen, Ziqian; Dragsted, Janne; Furbo, Simon

    2015-01-01

    A mathematical model simulating the emptying behavior of a pressurized solar collector loop with solar collectors with a good emptying behavior is developed and validated with measured data. The calculated results are in good agreement with the measured results. The developed simulation model...... is therefore suitable to determine the behavior of a solar collector loop during stagnation. A volume ratio R, which is the ratio of the volume of the vapour in the upper pipes of the solar collector loop during stagnation and the fluid content of solar collectors, is introduced to determine the mass...... of the collector fluid pushed into the expansion vessel during stagnation, Min. A correlation function for the mass Min and the volume ratio R for solar collector loops is obtained. The function can be used to determine a suitable size of expansion vessels for solar collector loops....

  12. Colored solar collectors - Annual report 2006

    Energy Technology Data Exchange (ETDEWEB)

    Schueler, A.; Chambrier, E. De; Roecker, Ch.; Scartezzini, J.-L.

    2007-12-15

    The architectural integration of thermal solar collectors into buildings is often limited by their black color, and the visibility of tubes and corrugations of the absorber sheets. A certain freedom in color choice would be desirable, but the colored appearance should not cause an excessive degradation of the collector efficiency. Multilayered thin film interference filters on the collector glazing can produce a colored reflection, hiding the corrugated metal sheet, while transmitting the non-reflected radiation entirely to the absorber. These interference filters are designed and optimized by numerical simulation, and are manufactured by sol-gel dip-coating or magnetron sputtering. The novel colored glazed solar collectors will be ideally suited for architectural integration into buildings, e.g. as solar active glass facades. Due to the tunability of the refractive index, nanostructured materials such as SiO{sub 2}:TiO{sub 2} composites and porous SiO{sub 2} are very useful for application in multilayer interference stacks. Novel quaternary Mg-F-Si-O films exhibit a surprisingly low refractive index and are therefore promising candidates for highly transparent coatings on solar collector glazing. The nanostructure of these thin films is studied by transmission electron microscopy, while the optical constants are measured precisely by ellipsometry. For a convincing demonstration, sufficiently large samples of high quality are imperatively needed. The fabrication of nanocomposite SiO{sub 2}:TiO{sub 2} films has been demonstrated by sol-gel dip-coating of A4-sized glass panes. The produced coatings exhibit a colored reflection in combination with a high solar transmittance, a homogenous appearance, and are free of visible defects. Film hardening by UV exposure will result in speeding up the sol-gel process and saving energy, thereby reducing costs significantly. The infrastructure for UV-curing has been established. A UV C radiation source can now be attached to the

  13. Support for solar energy collectors

    Science.gov (United States)

    Cole, Corey; Ardell-Smith, Zachary; Ciasulli, John; Jensen, Soren

    2016-11-01

    A solar energy collection system can include support devices configured to accommodate misalignment of components during assembly. For example, the system can include piles fixed to the earth and an adjustable bearing assembly at the upper end of the pile. The adjustable bearing assembly can include at least one of a vertical adjustment device, a lateral adjustment device and an angular adjustment device. The solar energy collection system can also include a plurality of solar energy collection device pre-wired together and mounted to a support member so as to form modular units. The system can also include enhanced supports for wire trays extending between rows of solar energy collection devices.

  14. Standardized performance tests of collectors of solar thermal energy: Prototype moderately concentrating grooved collectors

    Science.gov (United States)

    1976-01-01

    Prototypes of moderately concentrating grooved collectors were tested with a solar simulator for varying inlet temperature, flux level, and incident angle. Collector performance is correlated in terms of inlet temperature and flux level.

  15. Test results, Industrial Solar Technology parabolic trough solar collector

    Energy Technology Data Exchange (ETDEWEB)

    Dudley, V.E. [EG and G MSI, Albuquerque, NM (United States); Evans, L.R.; Matthews, C.W. [Sandia National Labs., Albuquerque, NM (United States)

    1995-11-01

    Sandia National Laboratories and Industrial Solar Technology are cost-sharing development of advanced parabolic trough technology. As part of this effort, several configurations of an IST solar collector were tested to determine the collector efficiency and thermal losses with black chrome and black nickel receiver selective coatings, combined with aluminized film and silver film reflectors, using standard Pyrex{reg_sign} and anti-reflective coated Pyrex{reg_sign} glass receiver envelopes. The development effort has been successful, producing an advanced collector with 77% optical efficiency, using silver-film reflectors, a black nickel receiver coating, and a solgel anti-reflective glass receiver envelope. For each receiver configuration, performance equations were empirically derived relating collector efficiency and thermal losses to the operating temperature. Finally, equations were derived showing collector performance as a function of input insolation value, incident angle, and operating temperature.

  16. A thermal comparison among several beverage can solar collectors.

    Science.gov (United States)

    Peter Y.S. Chen

    1984-01-01

    Four air-heated solar collectors were built using four different configurations of aluminum beverage cans. The collectors were then tested for four consecutive seasons for their daily efficiencies. One of the collectors was also evaluated for one season for the effect of air velocity on efficiency, temperature rise, and power consumption of the collector.

  17. Comparative analyses on dynamic performances of photovoltaic–thermal solar collectors integrated with phase change materials

    International Nuclear Information System (INIS)

    Su, Di; Jia, Yuting; Alva, Guruprasad; Liu, Lingkun; Fang, Guiyin

    2017-01-01

    Highlights: • The dynamic model of photovoltaic–thermal collector with phase change material was developed. • The performances of photovoltaic–thermal collector are performed comparative analyses. • The performances of photovoltaic–thermal collector with phase change material were evaluated. • Upper phase change material mode can improve performances of photovoltaic–thermal collector. - Abstract: The operating conditions (especially temperature) of photovoltaic–thermal solar collectors have significant influence on dynamic performance of the hybrid photovoltaic–thermal solar collectors. Only a small percentage of incoming solar radiation can be converted into electricity, and the rest is converted into heat. This heat leads to a decrease in efficiency of the photovoltaic module. In order to improve the performance of the hybrid photovoltaic–thermal solar collector, we performed comparative analyses on a hybrid photovoltaic–thermal solar collector integrated with phase change material. Electrical and thermal parameters like solar cell temperature, outlet temperature of air, electrical power, thermal power, electrical efficiency, thermal efficiency and overall efficiency are simulated and analyzed to evaluate the dynamic performance of the hybrid photovoltaic–thermal collector. It is found that the position of phase change material layer in the photovoltaic–thermal collector has a significant effect on the performance of the photovoltaic–thermal collector. The results indicate that upper phase change material mode in the photovoltaic–thermal collector can significantly improve the thermal and electrical performance of photovoltaic–thermal collector. It is found that overall efficiency of photovoltaic–thermal collector in ‘upper phase change material’ mode is 10.7% higher than that in ‘no phase change material’ mode. Further, for a photovoltaic–thermal collector with upper phase change material, it is verified that 3 cm

  18. Low cost thermal solar collector

    International Nuclear Information System (INIS)

    Abugderah, M. M.; Schneider, E. L.; Tontini, M. V.

    2006-01-01

    Solar energy is a good alternative in the economy of the electric energy mainly for the water heating. However, the solar heaters used demand a high initial investment, becoming the warm water from solar energy inaccessible to a large part of the society. Thus, a low cost solar heater was developed, constructed and tested in the chemical engineering department of West Parana State University-Unioeste. This equipment consists of 300 cans, divided in 30 columns of 10 cans each, all painted in black to enhance the obsorption of the solar radiation. The columns are connected to a pipe of pvc of 8 liters with 0.085m of external diameter. The equipment is capable to heat 120 liters of water in temperatures around 60 degree centigrade. The heater is insolated in its inferior part with cardboard and aluminum, covered with a transparent plastic in its superior. The system still counts with a insulated thermal reservoir, which can conserve the water in temperatures adjusted for the night non-solar days domestic use. The advantage of the constructed is it low cost material. The results are given an graphical tabular from showing acceptable efficiencies.(Autho

  19. Efficiencies of flat plate solar collectors at different flow rates

    DEFF Research Database (Denmark)

    Chen, Ziqian; Furbo, Simon; Perers, Bengt

    2012-01-01

    Two flat plate solar collectors for solar heating plants from Arcon Solvarme A/S are tested in a laboratory test facility for solar collectors at Technical University of Denmark (DTU). The collectors are designed in the same way. However, one collector is equipped with an ETFE foil between...... the absorber and the cover glass and the other is without ETFE foil. The efficiencies for the collectors are tested at different flow rates. On the basis of the measured efficiencies, the efficiencies for the collectors as functions of flow rate are obtained. The calculated efficiencies are in good agreement...... with the measured efficiencies....

  20. EFFICIENCY AND LIFETIME OF SOLAR COLLECTORS FOR SOLAR HEATING PLANTS

    DEFF Research Database (Denmark)

    The 12.5 m² flat plate solar collector HT, today marketed by Arcon Solvarme A/S, has been used in solar heating plants in Scandinavia since 1983. The collector is designed to operate in a temperature interval between 40°C and 90°C. The efficiency of the collector has been strongly improved since...... it was introduced on the market. The paper will present the increase of the efficiency of the collector due to technical improvements since 1983. Further, measurements from the spring of 2009 of the efficiency of two HT collectors, which have been in operation in the solar heating plant Ottrupgaard, Skørping......, Denmark since 1994 with a constant high flow rate and in the solar heating plant Marstal, Denmark since 1996 with a variable flow rate, will be presented. The efficiencies will be compared to the efficiencies of the collectors when they were first installed in the solar heating plants. The measurements...

  1. EFFICIENCY AND LIFETIME OF SOLAR COLLECTORS FOR SOLAR HEATING PLANTS

    DEFF Research Database (Denmark)

    Fan, Jianhua; Chen, Ziqian; Furbo, Simon

    2009-01-01

    The 12.5 m² flat plate solar collector HT, today marketed by Arcon Solvarme A/S, has been used in solar heating plants in Scandinavia since 1983. The collector is designed to operate in a temperature interval between 40°C and 90°C. The efficiency of the collector has been strongly improved since...... it was introduced on the market. The paper will present the increase of the efficiency of the collector due to technical improvements since 1983. Further, measurements from the spring of 2009 of the efficiency of two HT collectors, which have been in operation in the solar heating plant Ottrupgaard, Skørping......, Denmark since 1994 with a constant high flow rate and in the solar heating plant Marstal, Denmark since 1996 with a variable flow rate, will be presented. The efficiencies will be compared to the efficiencies of the collectors when they were first installed in the solar heating plants. The measurements...

  2. Solar collector design with respect to moisture problems

    DEFF Research Database (Denmark)

    Holck, Ole; Svendsen, Svend; Brunold, Stefan

    2003-01-01

    .Simulation of the microclimate in solar thermal collectors can be a valuable tool for optimisation of the collector with respect to ventilation. A computer model has been established for fulfilling this. By using this tool the producers can be advised whether their solar collectors ought to be additionally tightened, or whether...

  3. Protection of solar collector materials from UV

    Science.gov (United States)

    Castle, J. G., Jr.; Gause, R. L.; Whitaker, A.

    1978-01-01

    Certain plastic films, such as KAPTON, are known to be stable with excellent long-term aging characteristics under intense uv radiation. Our recent measurements of the optical transmission spectra of KAPTON films show an absorption edge in the blue and are interpreted in terms of an electronic excitation mechanism. The application of this type of film as covering for solar collectors is discussed in regard to the protection this strong uv absorption offers to the materials underneath.

  4. Adaptive control of solar energy collector systems

    CERN Document Server

    Lemos, João M; Igreja, José M

    2014-01-01

    This book describes methods for adaptive control of distributed-collector solar fields: plants that collect solar energy and deliver it in thermal form. Controller design methods are presented that can overcome difficulties found in these type of plants:they are distributed-parameter systems, i.e., systems with dynamics that depend on space as well as time;their dynamics is nonlinear, with a bilinear structure;there is a significant level of uncertainty in plant knowledge.Adaptive methods form the focus of the text because of the degree of uncertainty in the knowledge of plant dynamics. Parts

  5. Simulation of a solar collector array consisting of two types of solar collectors, with and without convection barrier

    DEFF Research Database (Denmark)

    Bava, Federico; Furbo, Simon; Perers, Bengt

    2015-01-01

    The installed area of solar collectors in solar heating fields is rapidly increasing in Denmark. In this scenario even relatively small performance improvements may lead to a large increase in the overall energy production. Both collectors with and without polymer foil, functioning as convection...... barrier, can be found on the Danish market. Depending on the temperature level at which the two types of collectors operate, one can perform better than the other. This project aimed to study the behavior of a 14 solar collector row made of these two different kinds of collectors, in order to optimize...... the composition of the row. Actual solar collectors available on the Danish market (models HT-SA and HT-A 35-10 manufactured by ARCON Solar A/S) were used for this analysis. To perform the study, a simulation model in TRNSYS was developed based on the Danish solar collector field in Braedstrup. A parametric...

  6. Evaluation of Test Method for Solar Collector Efficiency

    DEFF Research Database (Denmark)

    Fan, Jianhua; Shah, Louise Jivan; Furbo, Simon

    on these efficiencies, an efficiency equation is determined by regression analysis. In the test method, there are no requirements on the ambient air temperature and the sky temperature. The paper will present an evaluation of the test method for a 12.5 m² flat plate solar collector panel from Arcon Solvarme A....../S. The solar collector panel investigated has 16 parallel connected horizontal absorber fins. CFD (Computational Fluid Dynamics) simulations, calculations with a solar collector simulation program SOLEFF (Rasmussen and Svendsen, 1996) and thermal experiments are carried out in the investigation......The test method of the standard EN12975-2 (European Committee for Standardization, 2004) is used by European test laboratories to determine the efficiency of solar collectors. In the test methods the mean solar collector fluid temperature in the solar collector, Tm is determined by the approximated...

  7. Parabolic Trough Solar Collector Initial Trials

    OpenAIRE

    Ghalya Pikra; Agus Salim; Andri Joko Purwanto; Zaidan Eddy

    2012-01-01

    This paper discusses initial trials of parabolic trough solar collector (PTSC) in Bandung. PTSC model consists of concentrator, absorber and tracking system. Concentrator designs are made with 2m aperture width, 6m length and 0.75m focal distance. The design is equipped with an automatic tracking system which is driven using 12V and 24Watt DC motor with 0.0125rpm rotational speed. Absorber/receiver is designed with evacuated tube type, with 1 inch core diameter and tube made of AISI304 and co...

  8. THEORETICAL STUDY OF SOLAR COLLECTOR WITH MINI PARABOLIC CONCENTRATOR

    Directory of Open Access Journals (Sweden)

    I TABET

    2013-12-01

    Full Text Available In this paper, numerical modeling and simulation of the thermal behavior of a solar collector vacuum tube with a concentration has been done, the value of adding a system of concentration at the back of the collector and try to increase the amount of solar radiation incident on the collector  in order to obtain high temperatures compared to traditional flat plate collector  and improved their energy performance, this type of collector  being integrated into buildings for domestic hot water, air conditioning and for cooling.

  9. Study of Cylindrical Honeycomb Solar Collector

    Directory of Open Access Journals (Sweden)

    Atish Mozumder

    2014-01-01

    Full Text Available We present the results of our investigation on cylindrical honeycomb solar collector. The honeycomb has been fabricated with transparent cellulose triacetate polymer sheets. Insulation characteristics of the honeycomb were studied by varying the separation between the honeycomb and the absorber plate. The optimal value of the separation was found to be 3.3 mm for which the heat transfer coefficient is 3.06 W m−2 K−1. This supports result of previous similar experiments. Further we test the honeycomb through a field experiment conducted in Delhi (28.6°N, 77°E and found that when the incident angle of the solar radiation is within 20° then the performance of the system with the honeycomb is better than the one without the honeycomb.

  10. Development of 12.5 m² Solar Collector Panel for Solar Heating Plants

    DEFF Research Database (Denmark)

    Vejen, Niels Kristian; Furbo, Simon; Shah, Louise Jivan

    2004-01-01

    Theoretical and experimental investigations have elucidated how different changes in the design of the 12.5 m(2) HT flat-plate solar collector from the Danish company ARCON Solvarme A/S influence the solar collector efficiency and the yearly thermal performance. The collector is designed for medium...... and large solar heating systems. Based on the theoretical findings a prototype of an improved HT solar collector was built and tested side-by-side with the original HT solar collector. The improved HT collector makes use of a changed insulation material, an absorber with improved absorptance and emittance...

  11. Design package for concentrating solar collector panels

    Science.gov (United States)

    1978-01-01

    Information used to evaluate the design of the Northrup concentrating collector is presented. Included are the system performance specifications, the applications manual, and the detailed design drawings of the collector. The collector is a water/glycol/working fluid type, with a dipped galvanized steel housing, transparent acrylic Fresnel lens cover, copper absorber tube, and fiber glass insulation. It weights 98 pounds. A collector assembly includes four collector units within a tracking mount array.

  12. Mathematical modelling of unglazed solar collectors under extreme operating conditions

    DEFF Research Database (Denmark)

    Bunea, M.; Perers, Bengt; Eicher, S.

    2015-01-01

    average temperature levels at the evaporator. Simulation of these systems requires a collector model that can take into account operation at very low temperatures (below freezing) and under various weather conditions, particularly operation without solar irradiation.A solar collector mathematical model......Combined heat pumps and solar collectors got a renewed interest on the heating system market worldwide. Connected to the heat pump evaporator, unglazed solar collectors can considerably increase their efficiency, but they also raise the coefficient of performance of the heat pump with higher...... was found due to the condensation phenomenon and up to 40% due to frost under no solar irradiation. This work also points out the influence of the operating conditions on the collector's characteristics.Based on experiments carried out at a test facility, every heat flux on the absorber was separately...

  13. Efficiency improvement of flat plate solar collector using reflector

    Directory of Open Access Journals (Sweden)

    Himangshu Bhowmik

    2017-11-01

    Full Text Available Solar collectors are the main components of a solar heating system. The collectors collect the sun’s energy, transform this radiation into heat, and then transfer this heat into a fluid, water or air, which has many household or industrial applications. This paper introduces a new technology to improve the performance of the solar thermal collectors. The solar reflector used here with the solar collector to increase the reflectivity of the collector. Thus, the reflector concentrates both direct and diffuse radiation of the sun toward the collector. To maximize the intensity of incident radiation, the reflector was allowed to change its angle with daytime. The radiations coming from the sun’s energy were converted into heat, and then this heat was transferred to the collector fluid, water. A prototype of a solar water heating system was constructed and obtained the improvement of the collector efficiency around 10% by using the reflector. Thus, the present solar water heating systems having the best thermal performance compared to the available systems.

  14. Air solar collectors in building use - A review

    Science.gov (United States)

    Bejan, Andrei-Stelian; Labihi, Abdelouhab; Croitoru, Cristiana; Catalina, Tiberiu

    2018-02-01

    In the current energy and environmental context it is imperative to implement systems based on renewable energy sources in order to reduce energy consumptions worldwide. Solar collectors are studied by many years and many researchers are focusing their attention in order to increase their efficiency and cost-effectiveness. Water solar collectors are often implemented for domestic hot water, heating or industrial processes and already have a place on the market. A promising system which is not yet widely known is represented by air solar collectors that could represent an efficient way to use the solar energy with a lower investment cost, a system that can be used in order to preheat the fresh air required for heating, drying, or to maintain a minimum temperature during winter. This paper presents a comprehensive literature review on air solar collectors used mainly in buildings, acting as a solar wall. Air solar collectors are roughly classified into two types: glazed and opaque. The present study comprises the solar collector classification, applications and their main parameters with a special focus on opaque solar collectors.

  15. Air solar collectors in building use - A review

    Directory of Open Access Journals (Sweden)

    Bejan Andrei-Stelian

    2018-01-01

    Full Text Available In the current energy and environmental context it is imperative to implement systems based on renewable energy sources in order to reduce energy consumptions worldwide. Solar collectors are studied by many years and many researchers are focusing their attention in order to increase their efficiency and cost-effectiveness. Water solar collectors are often implemented for domestic hot water, heating or industrial processes and already have a place on the market. A promising system which is not yet widely known is represented by air solar collectors that could represent an efficient way to use the solar energy with a lower investment cost, a system that can be used in order to preheat the fresh air required for heating, drying, or to maintain a minimum temperature during winter. This paper presents a comprehensive literature review on air solar collectors used mainly in buildings, acting as a solar wall. Air solar collectors are roughly classified into two types: glazed and opaque. The present study comprises the solar collector classification, applications and their main parameters with a special focus on opaque solar collectors.

  16. High Performance Flat Plate Solar Thermal Collector Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Rockenbaugh, Caleb [National Renewable Energy Lab. (NREL), Golden, CO (United States); Dean, Jesse [National Renewable Energy Lab. (NREL), Golden, CO (United States); Lovullo, David [National Renewable Energy Lab. (NREL), Golden, CO (United States); Lisell, Lars [National Renewable Energy Lab. (NREL), Golden, CO (United States); Barker, Greg [National Renewable Energy Lab. (NREL), Golden, CO (United States); Hanckock, Ed [National Renewable Energy Lab. (NREL), Golden, CO (United States); Norton, Paul [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2016-09-01

    This report was prepared for the General Services Administration by the National Renewable Energy Laboratory. The Honeycomb Solar Thermal Collector (HSTC) is a flat plate solar thermal collector that shows promising high efficiencies over a wide range of climate zones. The technical objectives of this study are to: 1) verify collector performance, 2) compare that performance to other market-available collectors, 3) verify overheat protection, and 4) analyze the economic performance of the HSTC both at the demonstration sites and across a matrix of climate zones and utility markets.

  17. Development of solar air collectors for drying applications

    International Nuclear Information System (INIS)

    Karim, M.A.; Hawlader, M.N.A.

    2004-01-01

    In the present work, an experimental study of three types of solar air collectors, namely flat plate, finned and v-corrugated, has been performed towards achieving an efficient design of air collector suitable for a solar dryer. A series of experiments were conducted, based on the ASHRAE standard, under Singapore climatic conditions. The performance of all three collectors is examined over a wide range of operating and design conditions. The v-corrugated collector is found to be the most efficient collector and the flat plate collector the least efficient. The collectors are also studied in double pass mode to investigate the extent of improvement in efficiency that can be achieved without increasing the collector size or cost. Double pass operation of the collector leads to further improvement of the efficiency compared to the single pass of operation. The improvement in efficiency for the double pass mode is most significant in the flat plate collector and least in the v-groove collector

  18. Analysis of a solar collector field water flow network

    Science.gov (United States)

    Rohde, J. E.; Knoll, R. H.

    1976-01-01

    A number of methods are presented for minimizing the water flow variation in the solar collector field for the Solar Building Test Facility at the Langley Research Center. The solar collector field investigated consisted of collector panels connected in parallel between inlet and exit collector manifolds to form 12 rows. The rows were in turn connected in parallel between the main inlet and exit field manifolds to complete the field. The various solutions considered included various size manifolds, manifold area change, different locations for the inlets and exits to the manifolds, and orifices or flow control valves. Calculations showed that flow variations of less than 5 percent were obtainable both inside a row between solar collector panels and between various rows.

  19. Investigating the collector efficiency of silver nanofluids based direct absorption solar collectors

    International Nuclear Information System (INIS)

    Chen, Meijie; He, Yurong; Zhu, Jiaqi; Wen, Dongsheng

    2016-01-01

    Highlights: • An analysis coupled with Radiation transfer, Maxwell and Energy equation is developed. • Plasmonic Au and Ag nanofluids show better photo-thermal conversion properties. • Collector height and particle concentration exist optimum solutions for efficiency. - Abstract: A one-dimensional transient heat transfer analysis was carried out to analyze the effects of the Nanoparticle (NP) volume fraction, collector height, irradiation time, solar flux, and NP material on the collector efficiency. The numerical results were compared with the experimental results obtained by silver nanofluids to validate the model, and good agreement was obtained. The numerical results show that the collector efficiency increases as the collector height and NP volume fraction increase and then reaches a maximum value. An optimum collector height (∼10 mm) and particle concentration (∼0.03%) achieving a collector efficiency of 90% of the maximum efficiency can be obtained under the conditions used in the simulation. However, the collector efficiency decreases as the irradiation time increases owing to the increased heat loss. A high solar flux is desirable to maintain a high efficiency over a wide temperature range, which is beneficial for subsequent energy utilization. The modeling results also show silver and gold nanofluids obtain higher photothermal conversion efficiencies than the titanium dioxide nanofluid because their absorption spectra are similar to the solar radiation spectrum.

  20. ANALYSIS AND MODELING OF SOLAR EVAPORATOR-COLLECTOR

    Directory of Open Access Journals (Sweden)

    Zakaria Mohd. Amin

    2015-11-01

    Full Text Available Solar energy is considered a sustainable resource that poses little to no harmful effects on the environment. The performance of a solar system depends to a great extent on the collector used for the conversion of solar radiant energy to thermal energy. A solar evaporator-collector (SEC is basically an unglazed flat plate collector where refrigerants, such as R134a is used as the working fluid. As the operating temperature of the SEC is very low, it utilizes both solar irradiation and ambient energy leading to a much higher efficiency than the conventional collectors. This capability of SECs to utilize ambient energy also enables the system to operate at night. This type of collector can be locally made and is relatively much cheaper than the conventional collector.   At the National University of Singapore, the evaporator-collector was integrated to a heat pump and the performance was investigated for several thermal applications: (i water heating, (ii drying and (iii desalination. A 2-dimensional transient mathematical model of this system was developed and validated by experimental data. The present study provides a comprehensive study of performance. KEYWORDS: heat pump; evaporator-collector.

  1. CISBAT 2007 - Solar collectors (heat and electricity)

    International Nuclear Information System (INIS)

    2007-01-01

    This is the third part of the proceedings of the 2007 CISBAT conference on Renewables in a changing climate, held in Lausanne, Switzerland. On the subject of Building and urban integration of renewables the following oral contributions are summarised: 'Facade integration of solar thermal collectors: present and future', 'Long term experiences with a versatile PV in roof system', 'Development of a design and performance prediction tool for the ground source heat pump and underground thermal storage system', 'Hygrothermal performance of earth-to-air heat exchanger: long-term data evaluation and short-term simulation' as well as 'The real cost of heating your home: a comparative assessment of home energy systems with external costs'. Poster-sessions on the subject include 'Central solar heating plants with seasonal heat storage', 'Analysis of forced convection for evaporative air flow and heat transfer in PV cooling channels', 'Renewable energy technology in Mali: constraints and options for a sustainable development', 'Effect of duct width in ducted photovoltaic facades', 'Design and actual measurement of a ground source heat pump system using steel foundation piles as ground heat exchangers', 'Development of an integrated water-water heat pump unit for low energy house and its application', 'PV effect in multilayer cells and blending of fullerene/poly (3-hexylthiophene) and phthalocyanine having NIR charge transfer absorption band', 'CdTe photovoltaic systems - an alternative energetic', 'Integration of renewable energy sources in a town, examples in Grenoble', 'A prospective analysis method for the conception of solar integration solutions in buildings' and 'Energy and aesthetic improvements for building integration of cost effective solar energy systems'. Further groups of presentations at the conference are reported on in separate database records. An index of authors completes the proceedings

  2. Design and performance of multi-purpose vacuum solar collector

    Science.gov (United States)

    Balotaki, H. Kavoosi; Saidi, M. H.

    2017-09-01

    Design and fabrication of solar collectors with high performance of energy efficiency to convert solar energy to utility energy is vitally important. This article reports the results obtained from design, construction and investigation of the performance of a Combined Multi-Purpose Vacuum Solar Collector (CMPVSC). This collector consists of three sections: the vacuum section, the liquid section and the air section. In the present collector, it is capable of transferring heat to two flows (liquid and air) simultaneously and separate with the possibility of multipurpose applications. The CMPVSC is compared with the existing individual collectors and the effects of different parameters on the efficiency of this collector are examined. Experimental data indicate that high temperature and high performance with a 43% reduction in cost can be obtained using CMPVSC compared to two individual collectors. To increase the efficiency of the collector, triangular and rectangular channels in the air section have been used. The vacuum part is implemented to reduce heat losses. The effect of water inlet temperature, air flow rate, shape of air channel and vacuum part on the heat delivery by air and water have been investigated. Furthermore, as a matter of comparison of CMPVSC with the individual collector, there is a chance of obtaining highest temperature and efficiency with minimum cost and space requirements.

  3. Determination of the Optimum Collector Angle for Composite Solar ...

    African Journals Online (AJOL)

    A model for predicting solar radiation available at any given time in the inhabited area in Ilorin was developed. From the equation developed, the optimum tilt angle of the collector due south was carried out. The optimum angle of tilt of the collector and the orientation are dependent on the month of the year and the location ...

  4. Standardized performance tests of collectors of solar thermal energy - A flat-plate copper collector with parallel mylar striping

    Science.gov (United States)

    Johnson, S. M.

    1976-01-01

    Basic test results are reported for a flat plate solar collector whose performance was determined in a solar simulator. The collector was tested over ranges of inlet temperatures, fluxes and one coolant flow rate. Collector efficiency is correlated in terms of inlet temperature and flux level.

  5. Standardized performance tests of collectors of solar thermal energy: A selectively coated, steel collector with one transparent cover

    Science.gov (United States)

    1976-01-01

    Basic test results are presented of a flat-plate solar collector whose performance was determined in solar simulator. The collector was tested over ranges of inlet temperatures, fluxes and coolant flow rates. Collector efficiency was correlated in terms of inlet temperature and flux level.

  6. Standardized performance tests of collectors of solar thermal energy: An evacuated flatplate copper collector with a serpentine flow distribution

    Science.gov (United States)

    Johnson, S. M.

    1976-01-01

    Basic test results are given for a flat plate solar collector whose performance was determined in the NASA-Lewis solar simulator. The collector was tested over ranges of inlet temperatures, fluxes and one coolant flow rate. Collector efficiency is correlated in terms of inlet temperature and flux level.

  7. Study of an improved integrated collector-storage solar water heater combined with the photovoltaic cells

    International Nuclear Information System (INIS)

    Ziapour, Behrooz M.; Palideh, Vahid; Mohammadnia, Ali

    2014-01-01

    Highlights: • Simulation of an enhanced ICSSWH system combined with PV panel was conducted. • The present model dose not uses any photovoltaic driven water pump. • High packing factor and tank water mass are caused to high PVT system efficiency. • Larger area of the collector is resulted to lower total PVT system efficiency. - Abstract: A photovoltaic–thermal (PVT) module is a combination of a photovoltaic (PV) panel and a thermal collector for co-generation of heat and electricity. An integrated collector-storage solar water heater (ICSSWH) system, due to its simple and compact structure, offers a promising approach for the solar water heating in the varied climates. The combination of the ICSSWH system with a PV solar system has not been reported. In this paper, simulation of an enhanced ICSSWH system combined with the PV panel has been conducted. The proposed design acts passive. Therefore, it does not use any photovoltaic driven water pump to maintain a flow of water inside the collector. The effects of the solar cell packing factor, the tank water mass and the collector area on the performance of the present PVT system have been investigated. The simulation results showed that the high solar cell packing factor and the tank water mass are caused to the high total PVT system efficiency. Also, larger area of the collector is resulted to lower total PVT system efficiency

  8. Proceedings of the solar thermal concentrating collector technology symposium

    Energy Technology Data Exchange (ETDEWEB)

    Gupta, B.P.; Kreith, F. (eds.)

    1978-08-01

    The purpose of the symposium was to review the current status of the concentrating collector technology, to disseminate the information gained from experience in operating solar systems, and to highlight the significant areas of technology development that must be vigorously pursued to foster early commercialization of concentrating solar collectors. Separate abstracts were prepared for thirteen invited papers and working group summaries. Two papers were previously abstracted for EDB.

  9. Performance evaluation for solar collectors in Taiwan

    International Nuclear Information System (INIS)

    Chang, T.P.

    2009-01-01

    In this paper, the global irradiation observed in Taiwan from 1990 to 1999 was used to estimate the optimal tilt angle for solar collectors. The observed data are resolved into diffusion and beam components, and transformed into instantaneous time frames using mathematical models. The energy gain on installing a single-axis tracked panel as compared to a traditional fixed panel is originally analyzed theoretically. In addition to the observation data, both types of radiation will be taken into account for comparison, i.e. both extraterrestrial radiation and global radiation predicted using empirical models. The results show that the yearly optimal angles for six selected stations are about 0.95 and 0.88 times their latitudes for extraterrestrial and predicted radiation, respectively. All of the observed irradiations are less than the predicted values for all times and stations, consequently resulting in a flatter tilt angle, with a few exceptions in summer. Since Taipei has the lowest clearness index, its yearly optimal angle calculated from observed data shows the greatest discrepancy when compared to its latitude. By employing a tracked panel, the yearly gains calculated from the observed data lie between 14.3% and 25.3%, which is significantly less than those from the extraterrestrial and predicted radiations

  10. Parabolic Trough Solar Collector Initial Trials

    Directory of Open Access Journals (Sweden)

    Ghalya Pikra

    2012-03-01

    Full Text Available This paper discusses initial trials of parabolic trough solar collector (PTSC in Bandung. PTSC model consists of concentrator, absorber and tracking system. Concentrator designs are made with 2m aperture width, 6m length and 0.75m focal distance. The design is equipped with an automatic tracking system which is driven using 12V and 24Watt DC motor with 0.0125rpm rotational speed. Absorber/receiver is designed with evacuated tube type, with 1 inch core diameter and tube made of AISI304 and coated with black oxide, the outer tube is borosilicate glass with a 70 mm diameter and 1.5 m length. Working fluid stored in single type of thermal storage tank, a single phase with 37.7 liter volume. PTSC model testing carried out for 2 hours and 10 minutes produces heat output and input of 11.5 kW and 0.64 kW respectively. 

  11. Performance simulation of parabolic trough solar collector using two ...

    African Journals Online (AJOL)

    The Parabolic trough solar collector is considered as one of the most proven, mature and commercial concentrating solar systems implemented in arid and semi-arid regions for energy production. It focuses sunlight onto a solar receiver by using mirrors and is finally converted to a useful thermal energy by means of a heat ...

  12. Standard Test Method for Determining Thermal Performance of Tracking Concentrating Solar Collectors

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1987-01-01

    1.1 This test method covers the determination of thermal performance of tracking concentrating solar collectors that heat fluids for use in thermal systems. 1.2 This test method applies to one- or two-axis tracking reflecting concentrating collectors in which the fluid enters the collector through a single inlet and leaves the collector through a single outlet, and to those collectors where a single inlet and outlet can be effectively provided, such as into parallel inlets and outlets of multiple collector modules. 1.3 This test method is intended for those collectors whose design is such that the effects of diffuse irradiance on performance is negligible and whose performance can be characterized in terms of direct irradiance. Note 1—For purposes of clarification, this method shall apply to collectors with a geometric concentration ratio of seven or greater. 1.4 The collector may be tested either as a thermal collection subsystem where the effects of tracking errors have been essentially removed from t...

  13. FLOW DISTRIBUTION IN A SOLAR COLLECTOR PANEL WITH HORIZONTAL FINS

    DEFF Research Database (Denmark)

    Fan, Jianhua; Shah, Louise Jivan; Furbo, Simon

    2005-01-01

    The objective of this work is to theoretically and experimentally investigate the flow and temperature distribution in a solar collector panel with an absorber consisting of horizontal fins. Fluid flow and heat transfer in the collector panel are studied by means of computational fluid dynamics...... (CFD) calculations. Further, experimental investigations of a 12.5 m² solar collector panel with 16 parallel connected horizontal fins are carried out. The flow distribution through the absorber is evaluated by means of temperature measurements on the backside of the absorber tubes. The measured...

  14. Energy Analysis of Solar Collector With perforated Absorber Plate

    Directory of Open Access Journals (Sweden)

    Ammar A. Farhan

    2017-09-01

    Full Text Available The thermal performance of three solar collectors with 3, 6 mm and without perforation absorber plate was assessed experimentally. The experimental tests were implemented in Baghdad during the January and February 2017. Five values of airflow rates range between 0.01 – 0.1 m3/s were used through the test with a constant airflow rate during the test day. The variation of the following parameters air temperature difference, useful energy, absorber plate temperature, and collector efficiency was recorded every 15 minutes. The experimental data reports that the increases the number of absorber plate perforations with a small diameter is more efficient rather than increasing the hole diameter of the absorber plate with decreasing the perforation numbers. Maximum air temperature difference throughout the solar collector with 3, 6 mm perforations and without perforations are 17, 15, and 12 oC, respectively. Also, it can be concluded that the energy gained from the solar collector with 3 mm perforation absorber plate is 28.2 % more than the energy gained from solar collector without holes per day for 0.1 m3/s airflow rate. The maximum values of the thermal performance curves are 0.67, 0.64, and 0.56 for the solar collector with 3, 6 mm, and without perforations, respectively.

  15. Low-cost evacuated-tube solar collector. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Beecher, D. T.

    1981-02-10

    A prototype design for an evacuated tube air cooled solar collector module has been completed. A product cost study, based on the production of 60,000 of the prototype modules per year (approx. 1,000,000 square feet annually), estimates that the module as shipped would have a cost at inventory of $7.09 to $7.40 per square foot of aperture. Computer programs were developed to predict the optical and thermal performance of the module. Antireflective coatings (porous aluminum oxide) which could be formed by spraying or dipping were demonstrated but degraded more rapidly when exposed to a high humidity ambient than acid etched films. A selective black chromium oxide multi-layered graded film was vapor deposited which had an absorptivity of about 0.9 and an emissivity of 0.03. When the film was heated to temperatures of 400/sup 0/C in a gettered vacuum for as little as 24 hours, however, irreversible changes took place both between and within coating layers which resulted in ..cap alpha.. decreasing to about 0.73 and epsilon increasing to 0.14. The product cost studies indicate that module design changes are warranted to reduce product cost prior to tooling for production.

  16. An improved dynamic test method for solar collectors

    DEFF Research Database (Denmark)

    Kong, Weiqiang; Wang, Zhifeng; Fan, Jianhua

    2012-01-01

    A comprehensive improvement of the mathematical model for the so called transfer function method is presented in this study. This improved transfer function method can estimate the traditional solar collector parameters such as zero loss coefficient and heat loss coefficient. Two new collector...... parameters t and mfCf are obtained. t is a time scale parameter which can indicate the heat transfer ability of the solar collector. mfCf can be used to calculate the fluid volume content in the solar collector or to validate the regression process by comparing it to the physical fluid volume content...... for the second-order differential term with 6–9min as the best averaging time interval. The measured and predicted collector power output of the solar collector are compared during a test of 13days continuously both for the ITF method and the QDT method. The maximum and averaging error is 53.87W/m2 and 5.22W/m2...

  17. Low cost bare-plate solar air collector

    Science.gov (United States)

    Maag, W. L.; Wenzler, C. J.; Rom, F. E.; Vanarsdale, D. R.

    1980-09-01

    A low cost, bare plate solar collector for preheating ambient air was developed. This type of solar heating system would be applicable for preheating ventilation air for public buildings or other commercial and industrial ventilation requirements. Two prototype collectors were designed, fabricated and installed into an instrumented test system. Tests were conducted for a period of five months. Results of the tests showed consistent operating efficiencies of 60 percent or greater with air preheat temperature uses up to 20 degrees for one of the prototypes. The economic analyses indicated that this type of solar system was economically viable. For the materials of construction and the type of fabrication and installation perceived, costs for the bare plate solar collector are attainable. Applications for preheating ventilation air for schools were evaluated and judged to be economically viable.

  18. Opensource Software for MLR-Modelling of Solar Collectors

    DEFF Research Database (Denmark)

    Bacher, Peder; Perers, Bengt

    2011-01-01

    source program R http://www.r-project.org/. Applications of the software package includes: visual validation, resampling and conversion of data, collector performance testing analysis according to the European Standard EN 12975 (Fischer et al., 2004), statistical validation of results...... area flat plate collector with selective absorber and teflon anti convection layer. The package is intended to enable fast and reliable validation of data, and provide a united implementation for MLR testing of solar collectors. This will furthermore make it simple to replicate the calculations......A first research version is now in operation of a software package for multiple linear regression (MLR) modeling and analysis of solar collectors according to ideas originating all the way from Walletun et. al. (1986), Perers, (1987 and 1993). The tool has been implemented in the free and open...

  19. Solar-collector manufacturing activity, July through December, 1981

    Energy Technology Data Exchange (ETDEWEB)

    None

    1982-03-01

    Solar thermal collector and solar cell manufacturing activity is both summarized and tabulated. Data are compared for three survey periods (July through December, 1981; January through June, 1981; and July through December, 1980). Annual totals are also provided for the years 1979 through 1981. Data include total producer shipments, end use, market sector, imports and exports. (LEW)

  20. Performance of cylindrical plastic solar collectors for air heating

    International Nuclear Information System (INIS)

    Abdullah, A.S.; Bassiouny, M.K.

    2014-01-01

    Highlights: • The study including the combined convective and radiative heat transfer analysis. • The solar collector is manufactured from LDPE films acting as a black absorber. • Comparisons between the experimental data and the theoretical methods have been made. • The thermal efficiency increases with decreasing the major axes of elliptic shape. • The Nusselt number between the absorber and the heated air is determined. - Abstract: A theoretical and experimental study including the combined convective and radiative heat transfer analysis of a flexible cylindrical type solar air-heater for agriculture crops dehydration as well as heating processes is presented. The solar collector is manufactured from LDPE films acting as a black absorber with a back insulation and double transparent covers sealed together along its edges. The collector is to be blown with a flow of pressurized air. The experiments are carried out with solar collectors of circular shapes having 0.5 m diameter and solar collectors of elliptic shapes having 0.55 m and 0.65 m major axis. Energy balance of the cover, absorber and air yield three simultaneous quadratic algebraic equations in the three unknowns namely, cover, absorber and outlet air temperatures. A computer program is written for calculating the outlet temperature using the Newton–Raphson method and the collector thermal efficiency in terms of its diameter, length, mass flow rate, inlet temperature and solar insolation. Moreover the Nusselt number between the absorber and the heated air is determined experimentally in relation with the Reynolds number. Comparisons between the experimental data and the theoretical methods for the collector efficiency demonstrate a good agreement. In addition of this, the present experimental results of Nusselt number are correlated and compared with a correlation of another authors

  1. Fuzzy Approximate Model for Distributed Thermal Solar Collectors Control

    KAUST Repository

    Elmetennani, Shahrazed

    2014-07-01

    This paper deals with the problem of controlling concentrated solar collectors where the objective consists of making the outlet temperature of the collector tracking a desired reference. The performance of the novel approximate model based on fuzzy theory, which has been introduced by the authors in [1], is evaluated comparing to other methods in the literature. The proposed approximation is a low order state representation derived from the physical distributed model. It reproduces the temperature transfer dynamics through the collectors accurately and allows the simplification of the control design. Simulation results show interesting performance of the proposed controller.

  2. Performance of direct absorption solar collector with nanofluid mixture

    International Nuclear Information System (INIS)

    Turkyilmazoglu, Mustafa

    2016-01-01

    Highlights: • Neat approximations for temperature and solar collector efficiency are presented. • The non-adiabatic and isothermal base mechanisms optimize the surface absorption. • Heat transferring material at the bottom panel enhances the thermal efficiency. • Isothermal base panel leads to maximum thermal efficiency of the solar receiver. - Abstract: The enhancement of performance by increasing the thermal efficiency of a direct absorption solar collector based on an alumina–water nanofluid is the prime target of the present research. The base panel of the collector channel is subject to either a non adiabatic or an isothermal wall condition both of which introduce two new physical parameters. Analytical solutions for the temperature field are worked out in both cases for a two dimensional steady-state model recently outlined in the literature. The desired increase in the temperature of the heat transferring nanofluid is achieved either by slightly rising the heat transfer coefficient of the bottom panel coating or by prescribing a bottom surface temperature. As a consequence of the increase in the final outlet mean temperature, the solar collector thermal efficiency is found to be enhanced via increasing the new physical parameters as compared to the traditional adiabatic wall case. For instance, 85.63% thermal efficiency of solar collector is achievable for non adiabatic bottom panel by adding suspended aluminum nanoparticles into the pure water. Even better than this, considering isothermal base panels, 100% efficiency is attained more rapidly with lesser base temperatures in the presence of higher nanoparticle volume fractions.

  3. Parabolic dish collectors - A solar option

    Science.gov (United States)

    Truscello, V. C.

    1981-05-01

    A description is given of several parabolic-dish high temperature solar thermal systems currently undergoing performance trials. A single parabolic dish has the potential for generating 20 to 30 kW of electricity with fluid temperatures from 300 to 1650 C. Each dish is a complete power-producing unit, and may function either independently or as part of a group of linked modules. The two dish designs under consideration are of 11 and 12 meter diameters, yielding receiver operating temperatures of 925 and 815 C, respectively. The receiver designs described include (1) an organic working fluid (toluene) Rankine cycle engine; (2) a Brayton open cycle unit incorporating a hybrid combustion chamber and nozzle and a shaft-coupled permanent magnet alternator; and (3) a modified Stirling cycle device originally designed for automotive use. Also considered are thermal buffer energy storage and thermochemical transport and storage.

  4. Effect of openings collectors and solar irradiance on the thermal efficiency of flat plate-finned collector for indirect-type passive solar dryer

    Science.gov (United States)

    Batubara, Fatimah; Dina, Sari Farah; Klaudia Kathryn Y., M.; Turmuzi, M.; Siregar, Fitri; Panjaitan, Nora

    2017-06-01

    Research on the effect of openings solar collector and solar irradiance to thermal efficiency has been done. Solar collector by flat plate-finned type consists of 3 ply insulator namely wood, Styrofoam and Rockwool with thickness respectively are 10 mm, 25 mm and 50 mm. Absorber plate made of aluminum sheet with thickness of 0.30 mm, painted by black-doff. Installation of 19 units fins (length x height x thickness: 1000x20x10 mm) on the collector will increase surface area of absorber so it can receive much more solar energy. The solar collector cover is made of glass (thickness of 5 mm). During the research, the solar irradiance and temperature of collector are measured and recorded every five minutes. Temperature measurement performed on the surface of the absorber plate, inside of collector, surface cover and the outer side insulator (plywood). This data is used to calculate the heat loss due to conduction, convection and radiation on the collector. Openings of collectors vary as follows: 100%, 75%, 15% and 0% (total enclosed). The data collecting was conducted from 09.00 am to 17.00 pm and triplicates. The collector thermal efficiency calculated based on the ratio of the amount of heat received to the solar irradiance absorbed. The results show that each of openings solar collector has different solar irradiance (because it was done on a different day) which is in units of W/m2: 390 (100% open), 376 (75% open), 429 (15% open), and 359 (totally enclosed). The highest thermal efficiency is in openings variation of 15% opened. These results indicate that the efficiency of the collector is influenced by the solar irradiance received by the collector and the temperature on the collector plate. The highest thermal efficiency is in variation of openings 15%. These indicate that the efficiency of the collector was influenced by solar irradiance received by the collector and openings of the collector plate.

  5. IMPACT OF SOLAR RADIATION CHANGE ON THE COLLECTOR EFFICIENTLY

    Directory of Open Access Journals (Sweden)

    Danuta Proszak-Miąsik

    2017-01-01

    Full Text Available In October 2014 in a building of Rzeszow University of Technology, a series of measurements was taken to calculate the parameters of a solar system with a flat collector, as installed on the roof of the building. The following parameters were obtained: the value of solar radiation intensity, the temperature of external air, the temperature on the collector, the temperature of water in the tank and the temperature of glycol on the supply and return lines. On the basis of the data received, charts were made to visually present how changes of solar radiation intensity affected parameters of the system. The study was conducted in autumn when the intensity of solar radiation decreases, compared with summer months. The publication aims to show that the solar system brings energy gains in periods of transition, and the instantaneous intensity of solar radiation are comparable to those in the summer.

  6. Corrosion-free solar collectors for thermally driven seawater desalination

    Energy Technology Data Exchange (ETDEWEB)

    Hermann, M.; Koschikowski, J.; Rommel, M. [Fraunhofer Inst. for Solar Energy Systems ISE, Freiburg (Germany)

    2000-07-01

    Seawater desalination can be carried out by a variety of techniques, some of which are thermally driven at operating temperatures in the range of 60 to 80 deg. C. At this temperature level, these systems can be supplied by thermal energy gained from solar collectors. In order to increase the efficiency of such systems and simultaneously reduce costs, a heat exchanger between the collector loop and the desalination unit can be omitted if the seawater flows directly through the collectors. Since hot seawater is very aggressive, this configuration requires corrosion-free solar collectors. We developed selectively coated prototype collectors which fulfil this requirement. They will be installed in a pilot plant in Pozo Izquierdo, Gran Canaria, which will produce about 600 litres of desalinated water per day. This international project is funded by the European Commission DG XII, within the JOULE programme. The main task was to find materials which are resistant to seawater and can withstand temperatures up to 200 deg. C, which can occur under stagnation conditions. Moreover, it had to be ensured that it was possible to apply a selective coating on the absorber in order to increase the efficiency. A further limitation was given by the aim for the resulting water costs. After investigating different materials and collector designs, we developed a prototype consisting of an array of selectively coated glass tubes mounted in a conventional flat-plate collector housing. The efficiency was increased by adding a specially shaped reflector. The design was developed by carrying out both various optical and thermal simulations and indoor as well as outdoor tests. We obtained an appropriate collector which fulfilled the technical and economical requirements set by the special task of desalinating seawater. In-situ measurements at the test site in Gran Canaria will be carried out to gain more information about the long-term collector performance. (au)

  7. Analysis and validation of a quasi-dynamic model for a solar collector field with flat plate collectors and parabolic trough collectors in series for district heating

    DEFF Research Database (Denmark)

    Tian, Zhiyong; Perers, Bengt; Furbo, Simon

    2018-01-01

    A quasi-dynamic TRNSYS simulation model for a solar collector field with flat plate collectors and parabolic trough collectors in series was described and validated. A simplified method was implemented in TRNSYS in order to carry out long-term energy production analyses of the whole solar heating...... performance of the hybrid solar district heating plants is also presented. The measured and simulated results show that the integration of parabolic trough collectors in solar district heating plants can guarantee that the system produces hot water with relatively constant outlet temperature. The daily energy...... plant. The advantages of the model include faster computation with fewer resources, flexibility of different collector types in solar heating plant configuration and satisfactory accuracy in both dynamic and long-term analyses. In situ measurements were taken from a pilot solar heating plant with 5960 m...

  8. Development of a Polymer-carbon Nanotubes based Economic Solar Collector

    OpenAIRE

    Kim, S. I.; Kissick, John; Spence, Stephen; Boyle, Christine

    2014-01-01

    A low cost solar collector was developed by using polymeric components as opposed to metal and glass components of traditional solar collectors. In order to utilize polymers for the absorber of the solar collector, Carbon Nanotubes (CNT) has been added as a filler to improve the thermal conductivity and the solar absorptivity of polymers. The solar collector was designed as a multi-layer construction with considering the economic manufacturing. Through the mathematical heat transfer analysis,...

  9. A diagram for defined solar radiation absorbed per unit area of flat plate solar collectors

    Energy Technology Data Exchange (ETDEWEB)

    Tekin, Y.; Altuntop, N. [Erciyes University, Dept. of Mechanical Engineering (Turkey); Cengel, Y.A. [Nevada Reno University, Dept. of Mechanical Engineering, NV (United States); Cengel, Y.A. [Nevada University, Dept. Mechanical Engineering, Reno, NV (United States)

    2000-07-01

    In Erciyes University, the Solar House (28.75 m{sup 2}) is heated from the floor by using flat plate liquid solar collectors. Required solar radiation for heating and heat losses are calculated. In this work, the required calculations for Erciyes Solar House were generalized and required calculation were done to evaluate absorbed solar radiation per unit surface of the flat plate liquid collector. At the end, three generalized diagrams for nine different months are obtained using obtained numerical values. The goal of preparing diagrams is to determine absorbed solar radiation per unit surface area of flat plate liquid collector at any instant at any latitude, In this work, the diagram is explained by means of sample calculations for November. This diagram was prepared to find out absorbed solar radiation per unit area of black surface collector by means obtained equations. With this diagram, all instant solar radiation can be evaluated in 19 steps. (authors)

  10. Comparative test of two large solar collectors for solar field application

    DEFF Research Database (Denmark)

    Bava, Federico; Furbo, Simon

    2014-01-01

    Two large solar collectors for solar heating plants were tested according to the standard norm EN 12975-2. The two collectors were almost identical, the only difference being a thin FEP (fluorinated ethylene propylene) foil interposed between the absorber and the glass cover in one of them...

  11. Absorber Alignment Measurement Tool for Solar Parabolic Trough Collectors: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Stynes, J. K.; Ihas, B.

    2012-04-01

    As we pursue efforts to lower the capital and installation costs of parabolic trough solar collectors, it is essential to maintain high optical performance. While there are many optical tools available to measure the reflector slope errors of parabolic trough solar collectors, there are few tools to measure the absorber alignment. A new method is presented here to measure the absorber alignment in two dimensions to within 0.5 cm. The absorber alignment is measured using a digital camera and four photogrammetric targets. Physical contact with the receiver absorber or glass is not necessary. The alignment of the absorber is measured along its full length so that sagging of the absorber can be quantified with this technique. The resulting absorber alignment measurement provides critical information required to accurately determine the intercept factor of a collector.

  12. Design and Development of a Solar Thermal Collector with Single Axis Solar Tracking Mechanism

    Directory of Open Access Journals (Sweden)

    Theebhan Mogana

    2016-01-01

    Full Text Available The solar energy is a source of energy that is abundant in Malaysia and can be easily harvested. However, because of the rotation of the Earth about its axis, it is impossible to harvest the solar energy to the maximum capacity if the solar thermal collector is placed fix to a certain angle. In this research, a solar thermal dish with single axis solar tracking mechanism that will rotate the dish according to the position of the sun in the sky is designed and developed, so that more solar rays can be reflected to a focal point and solar thermal energy can be harvested from the focal point. Data were collected for different weather conditions and performance of the solar thermal collector with a solar tracker were studied and compared with stationary solar thermal collector.

  13. Review of state-of-the art of solar collector corrosion processes. Task 1 of solar collector studies for solar heating and cooling applications

    Science.gov (United States)

    Clifford, J. E.; Diegle, R. B.

    1980-04-01

    The state of the art of solar collector corrosion processes is reviewed, and Task 1 of a current research program on use of aqueous heat transfer fluids for solar heating and cooling is summarized. The review of available published literature indicated that lack of quantitative information exists relative to collector corrosion at the present time, particularly for the higher temperature applications of solar heating and cooling compared to domestic water heating. Solar collector systems are reviewed from the corrosion/service life viewpoint, with emphasis on various applications, collector design, heat transfer fluids, and freeze protection methods. Available information (mostly qualitative) on collector corrosion technology is reviewed to indicate potential corrosion problem areas and corrosion prevention practices.

  14. Dynamic Modeling of Natural Convection Solar Energy Collector

    African Journals Online (AJOL)

    NIJOTECH

    the use of man-made equipment for its collection and utilization becomes .... mean values necessitating the replacement of their time rates of change by total differentials. (ii) Since the heat capacity ..... D.V.C., Optimal Efficiencies of One-, Two-, and Three-cover Flat plate Solar Energy Thermal. Collector, Nigerian Journal Of ...

  15. Dynamic Modeling of Natural Convection Solar Energy Collector

    African Journals Online (AJOL)

    NIJOTECH

    formally called plates efficiency). A plot of the collector output parameters against time from Os (at 6.00a/m.) showed that each possessed a maximum, which occurred between 1800s and 3600s after solar noon where global radiation had its ...

  16. Facade integration of solar thermal collectors. A breakthrough

    Energy Technology Data Exchange (ETDEWEB)

    Roecker, Christian; Munari-Probst, MariaCristina; Chambrier, Estelle de; Schueler, Andreas; Scartezzini, Jean-Louis [Ecole Polytechnique Federale de Lausanne (EPFL), Lausanne (Switzerland). Lab. d' Energie Solaire et de Physique du Batiment

    2008-07-01

    One main barrier to the acceptability of facade use of solar thermal collectors is their black appearance and the visibility of piping or absorber irregularities through the glazing. To facilitate facade integration, a project was set up to develop selective filters reflecting only a small part of the solar spectrum in the visible range while letting the rest of the radiation heat the absorber. These filters were successfully produced and, combined with a diffusing glass treatment, have achieved the desired masking effect with minor impact on the collector efficiency (less than 10%). Glasses of various colours combined with several diffusing finishing (acid etching, structured glass etc..) can be produced that are able to hide the absorber. Such glazings will allow the use of the same product both in front of facade areas equipped with solar absorbers (as collector external glass) and in front of the non exposed areas (as facade cladding), opening the way to a broad variety of active facade designs. The active elements can then be positioned at will on the exposed areas, and their quantity determined only by thermal needs. By freeing the dimension of the facade area that can be clad with this glazing from the thermally needed surface for collectors, a major step to help architects use solar thermal on facades has been taken. (orig.)

  17. Performance Simulation Comparison for Parabolic Trough Solar Collectors in China

    Directory of Open Access Journals (Sweden)

    Jinping Wang

    2016-01-01

    Full Text Available Parabolic trough systems are the most used concentrated solar power technology. The operating performance and optical efficiency of the parabolic trough solar collectors (PTCs are different in different regions and different seasons. To determine the optimum design and operation of the parabolic trough solar collector throughout the year, an accurate estimation of the daily performance is needed. In this study, a mathematical model for the optical efficiency of the parabolic trough solar collector was established and three typical regions of solar thermal utilization in China were selected. The performance characteristics of cosine effect, shadowing effect, end loss effect, and optical efficiency were calculated and simulated during a whole year in these three areas by using the mathematical model. The simulation results show that the optical efficiency of PTCs changes from 0.4 to 0.8 in a whole year. The highest optical efficiency of PTCs is in June and the lowest is in December. The optical efficiency of PTCs is mainly influenced by the solar incidence angle. The model is validated by comparing the test results in parabolic trough power plant, with relative error range of 1% to about 5%.

  18. Development of a Solar Assisted Drying System Using Double-Pass Solar Collector with Finned Absorber

    International Nuclear Information System (INIS)

    Azmi, M S M; Sopian, K; Ruslan, M H; Fudholi, A; Majid, Z A A; Yasin, J M; Othman, M Y

    2012-01-01

    The Solar Energy Research Group, Universiti Kebangsaan Malaysia, International Islamic University Malaysia and Yayasan FELDA has designed and constructed a solar assisted drying system at OPF FELDA Factory, Felda Bukit Sagu 2, Kuantan, Pahang. The drying system has a total of six double-pass solar collectors. Each collector has a length of 480 cm and a width of 120 cm. The first channel depth is 3.5 cm and the second channel depth is 7 cm. Longitudinal fins made of angle aluminium, 0.8 mm thickness were attached to the bottom surface of the absorber plate. The solar collectors are arranged as two banks of three collectors each in series. Internal manifold are used to connect the collectors. Air enters through the first channel and then through the second channel of the collector. An auxiliary heater source is installed to supply heat under unfavourable solar radiation condition. An on/off controller is used to control the startup and shutdown of the auxiliary heater. An outlet temperature of 70–75 °C can be achieved at solar radiation range of 800–900 W/m 2 and flow rate of 0.12 kg/s. The average thermal efficiency of a solar collector is approximately 37%.

  19. Development of a Solar Assisted Drying System Using Double-Pass Solar Collector with Finned Absorber

    Science.gov (United States)

    Azmi, M. S. M.; Othman, M. Y.; Sopian, K.; Ruslan, M. H.; Majid, Z. A. A.; Fudholi, A.; Yasin, J. M.

    2012-09-01

    The Solar Energy Research Group, Universiti Kebangsaan Malaysia, International Islamic University Malaysia and Yayasan FELDA has designed and constructed a solar assisted drying system at OPF FELDA Factory, Felda Bukit Sagu 2, Kuantan, Pahang. The drying system has a total of six double-pass solar collectors. Each collector has a length of 480 cm and a width of 120 cm. The first channel depth is 3.5 cm and the second channel depth is 7 cm. Longitudinal fins made of angle aluminium, 0.8 mm thickness were attached to the bottom surface of the absorber plate. The solar collectors are arranged as two banks of three collectors each in series. Internal manifold are used to connect the collectors. Air enters through the first channel and then through the second channel of the collector. An auxiliary heater source is installed to supply heat under unfavourable solar radiation condition. An on/off controller is used to control the startup and shutdown of the auxiliary heater. An outlet temperature of 70-75 °C can be achieved at solar radiation range of 800-900 W/m2 and flow rate of 0.12 kg/s. The average thermal efficiency of a solar collector is approximately 37%.

  20. Analytical thermal analysis of air-heating solar collectors

    Energy Technology Data Exchange (ETDEWEB)

    Ghasemi, S. E.; Hatami, M.; Ganji, D. D. [Babol University of Technology, Babol (Iran, Islamic Republic of)

    2013-11-15

    In this paper, Optimal homotopy asymptotic method (OHAM) and homotopy perturbation method (HPM) are applied to investigate heat transfer in the air-heating flat-plate solar collectors. Results for different values of active parameters are compared with numerical method (fourth order Runge-Kutta method). The results confirm the notion that the HPM method is more accurate than OHAM and efficient technique for finding exact solutions for differential equations which have great significance in different fields of science and engineering. Effects of air flow rate, width and length of the collector on thermal efficiency are examined. As an important outcome, increasing in the collector's dimensions (width and length) make a decreasing in thermal efficiency, but increasing in air mass flow rates improve it.

  1. Thermodynamic analysis of air solar collector

    International Nuclear Information System (INIS)

    Luminosu, Loan; Fara, Laurentiu

    2006-01-01

    The paper presents the experimental study of an air solar installation with a collecting area A c =4.2m 2 and variable working fluid flow rate in the range 0.02/0.06 kg/s. The experimental data are processed statistically through thermodynamic analysis using energy (semi-empirical and exergy methods. The aim of the paper is to establish the optimal air flow rate through this solar thermal system in order to ensure minimum irreversibility of the collecting-heating-cooling process under Romania's insolation conditions. The paper is also a demonstrative example of cost-effective and efficient use of solar energy for heating in Romania. It is experimentally proven that for this solar installation, the optimum air flow rate is of 0.04 kg/s. At a flow rate of 0.04 kg/s, irreversibility has the lowest values for all daytime hours with a maximum at noon (2640 W). For this flow rate the energy efficiency reaches the highest values. The maximum exergy efficiency value is 0 e x-max=0.197. In March 2000 the solar installation operated as an alternative thermal source for heating a garage, having an inner volume V=64.5 m 3 . The efficiency of the solar installation used for heating the garage is η=0.321. The economic ratio defined as the ratio between monetary benefit and financial investment is r=1.82. A value above 1 of ration r shows the economic utility of the solar installation for users who need thermal energy at low heat carrier levels. The study is useful to designers and users of solar thermal systems inCentral Europe as well as in other geographical areas where climatic conditions are comparable to those in South-Western Romania.(Author)

  2. Corrosion-free solar collectors for thermally driven seawater desalination

    Energy Technology Data Exchange (ETDEWEB)

    Hermann, M.; Koschikowski, J.; Rommel, M. [Fraunhofer Institute for Solar Energy Systems, Freiburg (Germany)

    2002-05-01

    Seawater desalination can be carried out by a variety of techniques, some of which are thermally driven at operating temperatures in the range of 70 to 120{sup o}C. At this temperature level, these systems can be supplied with thermal energy gained from solar flat-plate collectors. In order to increase the efficiency of such systems and simultaneously reduce costs, a heat exchanger between the collector loop and the desalination unit can be omitted if the seawater flows directly through the collector absorbers. Since hot seawater is very aggressive, this configuration requires corrosion-free absorbers. We developed collectors which fulfil this requirement. They were installed in a pilot plant in Pozo lzquierdo, Gran Canaria, which produces about 600 l of drinking water per day. The main task was to find materials which are resistant to seawater and can withstand stagnation temperatures up to 200{sup o}C, out of which appropriate absorber constructions had to be developed. Moreover, it had to be ensured that it was possible to apply a selective coating on the absorber. A further limitation was given by the aim for the resulting water costs. After investigating different materials and collector designs, we developed a prototype consisting of an array of selectively coated glass tubes mounted in a conventional flat-plate collector housing. The efficiency was increased by adding a specially shaped reflector. The design was developed by carrying out various optical and thermal simulations, and indoor as well as outdoor tests. We obtained appropriate collectors which fulfil the technical and economical requirements. Finally, first results of the in-situ measurements in Gran Canaria will be presented. (author)

  3. Standarized performance tests of collectors of solar thermal energy: A steel flat-plate collector with two transparent covers and a proprietary coating

    Science.gov (United States)

    1976-01-01

    Basic test results of a flat-plate solar collector whose performance was determined in the NASA-Lewis solar simulator are given. The collector was tested over ranges of inlet temperature and flux level.

  4. Solar collector performance evaluated outdoors at NASA-Lewis Research Center

    Science.gov (United States)

    Vernon, R. W.

    1974-01-01

    The study of solar reflector performance reported is related to a project in which solar collectors are to be provided for the solar heating and cooling system of an office building at NASA's Langley Research Center. The solar collector makes use of a liquid consisting of 50% ethylene glycol and 50% water. A conventional air-liquid heat exchanger is employed. Collector performance and solar insolation data are recorded along with air temperature, wind speed and direction, and relative humidity.

  5. Models of the heat dynamics of solar collectors for performance testing

    DEFF Research Database (Denmark)

    Bacher, Peder; Madsen, Henrik; Perers, Bengt

    2011-01-01

    The need for fast and accurate performance testing of solar collectors is increasing. This paper describes a new technique for performance testing which is based on non-linear continuous time models of the heat dynamics of the collector. It is shown that all important performance parameters can...... be accurately estimated with measurements from a single day. The estimated parameters are compared with results from standardized test methods (Fischer et al., 2004). Modelling the dynamics of the collector is carried out using stochastic differential equations, which is a well proven efficient method to obtain...... accurate estimates of parameters in physical models. The applied method is described by Kristensen et al. (2004) and implemented in the software CTSM1. Examples of successful applications of the method includes modelling the of the heat dynamics of integrated photo-voltaic modules (Friling et al., 2009...

  6. Design of a solar-assisted drying system using the double-pass solar collector

    International Nuclear Information System (INIS)

    Sopian, K.; Daud, W.R.; Supranto; Othman, M.Y.; Yatim, B.

    2000-01-01

    A solar-assisted drying system that uses the double-pass solar collector with porous media in the second channel has been designed and constructed at the Solar Energy Research Park, Universiti Kebangsaan Malaysia. The drying system has a total of six double-pass solar collectors. Each collector has a length of 240 cm and a width of 120 cm. The upper channel depth is 3.5 cm and the lower channel depth is 10.5 cm. The lower channel is filled up with steel wool as the porous media. The solar collectors are arranged as 2 banks of 3 collectors each in series. Internal manifold are used to connect the collectors. An auxiliary heater source is installed to supply heat under unfavourable solar radiation conditions. An on/off controller is used to control the startup and shutdown of the auxiliary heater. An outlet temperature of 80-90 0 C can be achieved at a solar radiation range of 800-900 W/m 3 , ambient temperature of 29 degree C and flow rate of O.20 kg/s. (Author)

  7. Review of state-of-the-art of solar collector corrosion processes. Task 1 of solar collector studies for solar heating and cooling applications. Final technical progress report

    Energy Technology Data Exchange (ETDEWEB)

    Clifford, J E; Diegle, R B

    1980-04-11

    The state-of-the-art of solar collector corrosion processes is reviewed, and Task 1 of a current research program on use of aqueous heat transfer fluids for solar heating and cooling is summarized. The review of available published literature has indicated that lack of quantitative information exists relative to collector corrosion at the present time, particularly for the higher temperature applications of solar heating and cooling compared to domestic water heating. Solar collector systems are reviewed from the corrosion/service life viewpoint, with emphasis on various applications, collector design, heat transfer fluids, and freeze protection methods. Available information (mostly qualitative) on collector corrosion technology is reviewed to indicate potential corrosion problem areas and corrosion prevention practices. Sources of limited quantitative data that are reviewed are current solar applications, research programs on collector corrosion, and pertinent experience in related applications of automotive cooling and non-solar heating and cooling. A data bank was developed to catalog corrosion information. Appendix A of this report is a bibliography of the data bank, with abstracts reproduced from presently available literature accessions (about 220). This report is presented as a descriptive summary of information that is contained in the data bank.

  8. Application of Induction Heating for Brazing Parts of Solar Collectors

    Directory of Open Access Journals (Sweden)

    Kristína Demianová

    2012-01-01

    Full Text Available This paper reports on the application of induction heating for brazing parts of solar collectors made of Al alloys. The tube-flange joint is a part of the collecting pipe of a solar collector. The main task was to design an induction coil for this type of joint, and to select the optimum brazing parameters. Brazing was performed with AlSi12 brazing alloy, and corrosive and non-corrosive flux types were also applied. The optimum brazing parameters were determined on the basis of testing the fabricated brazed joints by visual inspection, by leakage tests, and by macro- and micro-analysis of the joint boundary. The following conditions can be considered to be the best for brazing Al materials: power 2.69 kW,brazing time 24 s, flux BrazeTec F32/80.

  9. Water heating solar system using collector with polycarbonate absorber surface

    Energy Technology Data Exchange (ETDEWEB)

    Souza, Luiz Guilherme Meira de; Sodre, Dilton; Cavalcanti, Eduardo Jose Cidade; Souza, Luiz Guilherme Vieira Meira de; Mendes, Jose Ubiragi de Lima [Universidade Federal do Rio Grande do Norte (UFRN), Natal, RN (Brazil)], e-mails: lguilherme@dem.ufrn.br, diltonsodre@ifba.edu.br, ubiragi@ct.ufrn.br

    2010-07-01

    It is presented s solar collector to be used in a heating water for bath system, whose main characteristics are low cost and easy fabrication and assembly processes. The collector absorber surface consists of a polycarbonate plate with an area of 1.5 m{sup 2}. The water inlet and outlet are made of PVC 50mm, and were coupled to a 6mm thick polycarbonate plate using fiberglass resin. A 200 liters thermal reservoir will be used. This reservoir is also alternative. The absorber heating system works under thermo-siphon regimen. Thermal parameters will be evaluated to prove the feasibility of the studied solar heating system to obtain bath water for a four people family. (author)

  10. Efficiency of liquid flat-plate solar energy collector with solar tracking system

    Directory of Open Access Journals (Sweden)

    Chekerovska Marija

    2015-01-01

    Full Text Available An extensive testing programme is performed on a solar collector experimental set-up, installed on a location in Shtip (Republic of Macedonia, latitude 41º 45’ and longitude 22º 12’, in order to investigate the effect of the sun tracking system implementation on the collector efficiency. The set-up consists of two flat plate solar collectors, one with a fixed surface tilted at 30о towards the South, and the other one equipped with dual-axis rotation system. The study includes development of a 3-D mathematical model of the collectors system and a numerical simulation programme, based on the computational fluid dynamics (CFD approach. The main aim of the mathematical modelling is to provide information on conduction, convection and radiation heat transfer, so as to simulate the heat transfer performances and the energy capture capabilities of the fixed and moving collectors in various operating modes. The feasibility of the proposed method was confirmed by experimental verification, showing significant increase of the daily energy capture by the moving collector, compared to the immobile collector unit. The comparative analysis demonstrates a good agreement between the experimental and numerically predicted results at different running conditions, which is a proof that the presented CFD modelling approach can be used for further investigations of different solar collectors configurations and flow schemes.

  11. Low-cost solar collectors using thin-film plastics absorbers and glazings

    Energy Technology Data Exchange (ETDEWEB)

    Wilhelm, W.G.

    1980-01-01

    The design, fabrication, performance, cost, and marketing of flat plate solar collectors using plastic absorbers and glazings are described. Manufacturing cost breakdowns are given for single-glazed and double-glazed collectors. (WHK)

  12. EVALUATION OF EVACUATED TUBULAR SOLAR COLLECTORS FOR LARGE SDHW SYSTEMS AND COMBINED SPACE HEATING SYSTEMS

    DEFF Research Database (Denmark)

    Qin, Lin; Furbo, Simon

    1999-01-01

    . Based on thesemodels, the thermal performance of large solar domestic hot water (DHW) systems and combined domestichot water and space heating systems with the four evacuated tubular collectors was determined. To make acomparison with traditional flat-plate collectors, similar simulations were also......In the present study, detailed investigations on evacuated tubular solar collectors for large solarheating systems have been carried out. Four types of evacuated tubular solar collectors were used in theinvestigation. Based on laboratory tests, simulation models for the collectors were determined...... carried out for systems with atypical flat-plate collector. The results show that the thermal advantage of evacuated tubular collectors variesgreatly from system to system, and increases with the solar fraction. Furthermore, the higher the operationtemperature of the collector in the system is...

  13. Insect Thin Films as Sun Blocks, Not Solar Collectors

    Science.gov (United States)

    Koon, Daniel W.; Crawford, Andrew B.

    2000-05-01

    We measured the visible reflectance spectra of whole wing sections from three species of iridescent butterflies and moths, for normal incidence, integrated over all reflected angles. In this manner, we separated the optics of the thin films causing the iridescence from the optics of the rest of the scale. We found that iridescence reduces solar absorption by the wing in all cases, typically by approximately 20% or less, in contrast to claims by Miaoulis and Heilman Ann. Entomol. Soc. Am. 91, 122 (1998) that the thin-film structures that produce iridescence act as solar collectors.

  14. Development and investigation of solar collectors for conversion of solar radiation into heat and/or electricity

    Directory of Open Access Journals (Sweden)

    Stefanović Velimir P.

    2006-01-01

    Full Text Available This article describes work on two projects of the National Energy Efficiency Program NEEP 709300036 and NPEE 271003 titled "The model of solar collector for middle temperature conversion of solar radiation in heat" and "Development and investigation on hybrid solar collector for heat and electricity generation", respectively. This first project deals with solar collector that transfers solar radiation in heat in area of middle temperature conversion (at temperatures above 100 ºC. During entire year it can realize significant saving of electric energy used for preparation of warm water and in central and district heating. During work on the second project, two hybrid solar collectors, their installation, mathematical model, software, and experimental set-up were designed and realized. The first collector had the photovoltaic panel located above the absorber and the second collector had the panel located on the absorber. For both collectors, the results show that efficiency of fossil fuel replacement is 85%. .

  15. Performance of double –pass solar collector with CPC and fins for heat transfer enhancement

    International Nuclear Information System (INIS)

    Alfegi, Ebrahim M A; Abosbaia, Alhadi A S; Mezughi, Khaled M A; Sopian, Kamaruzzaman

    2013-01-01

    The temperature of photovoltaic modules increases when it absorbs solar radiation, causing a decrease in efficiency. This undesirable effect can be partially avoided by applying a heat recovery unit with fluid circulation (air or water) with the photovoltaic module. Such unit is called photovoltaic / thermal collector (pv/t) or hybrid (pv/t). In this unit, photovoltaic cells were pasted directly on the flat plate absorber. An experimental study of a solar air heater with photovoltaic cell located at the absorber with fins and compound parabolic collector for heat transfer enhancement and increasing the number of reflection on the cells have been conducted. The performance of the photovoltaic, thermal, and combined pv/t collector over range of operating conditions and the results was discussed. Results at solar irradiance of 500 W/m 2 show that the combined pv/t efficiency is increasing from 37.28 % to 81.41 % at mass flow rates various from 0.029 to 0.436 kg/s.

  16. Performance of double -pass solar collector with CPC and fins for heat transfer enhancement

    Science.gov (United States)

    Alfegi, Ebrahim M. A.; Abosbaia, Alhadi A. S.; Mezughi, Khaled M. A.; Sopian, Kamaruzzaman

    2013-06-01

    The temperature of photovoltaic modules increases when it absorbs solar radiation, causing a decrease in efficiency. This undesirable effect can be partially avoided by applying a heat recovery unit with fluid circulation (air or water) with the photovoltaic module. Such unit is called photovoltaic / thermal collector (pv/t) or hybrid (pv/t). In this unit, photovoltaic cells were pasted directly on the flat plate absorber. An experimental study of a solar air heater with photovoltaic cell located at the absorber with fins and compound parabolic collector for heat transfer enhancement and increasing the number of reflection on the cells have been conducted. The performance of the photovoltaic, thermal, and combined pv/t collector over range of operating conditions and the results was discussed. Results at solar irradiance of 500 W/m2 show that the combined pv/t efficiency is increasing from 37.28 % to 81.41 % at mass flow rates various from 0.029 to 0.436 kg/s.

  17. Optimal tilt-angles of all-glass evacuated tube solar collectors

    International Nuclear Information System (INIS)

    Tang, Runsheng; Gao, Wenfeng; Yu, Yamei; Chen, Hua

    2009-01-01

    In this paper, a detailed mathematical procedure is developed to estimate daily collectible radiation on single tube of all-glass evacuated tube solar collectors based on solar geometry, knowledge of two-dimensional radiation transfer. Results shows that the annual collectible radiation on a tube is affected by many factors such as collector type, central distance between tubes, size of solar tubes, tilt and azimuth angles, use of diffuse flat reflector (DFR, in short); For collectors with identical parameters, T-type collectors (collectors with solar tubes tilt-arranged) annually collect slightly more radiation than H-type collectors (those with solar tubes horizontally arranged) do. The use of DFR can significantly improve the energy collection of collectors. Unlike the flat-plate collectors, all-glass evacuated tube solar collectors should be generally mounted with a tilt-angle less than the site latitude in order to maximize the annual energy collection. For most areas with the site latitude larger than 30 o in China, T-type collectors should be installed with a tilt-angle about 10 o less than the site latitude, whereas for H-type collectors without DFR, the reasonable tilt-angle should be about 20 o less than the site latitude. Effects of some parameters on the annual collectible radiation on the collectors are also presented.

  18. Solar energy modulator

    Science.gov (United States)

    Hale, R. R. (Inventor); Mcdougal, A. R.

    1984-01-01

    A module is described with a receiver having a solar energy acceptance opening and supported by a mounting ring along the optic axis of a parabolic mirror in coaxial alignment for receiving solar energy from the mirror, and a solar flux modulator plate for varying the quantity of solar energy flux received by the acceptance opening of the module. The modulator plate is characterized by an annular, plate-like body, the internal diameter of which is equal to or slightly greater than the diameter of the solar energy acceptance opening of the receiver. Slave cylinders are connected to the modulator plate for supporting the plate for axial displacement along the axis of the mirror, therby shading the opening with respect to solar energy flux reflected from the surface of the mirror to the solar energy acceptance opening.

  19. Research and Development of a Low Cost Solar Collector

    Energy Technology Data Exchange (ETDEWEB)

    Ansari, Asif; Philip, Lee; Thouppuarachchi, Chirath

    2012-08-01

    This is a Final Technical Report on the Research and Development completed towards the development of a Low Cost Solar Collector conducted under the DOE cost-sharing award EE-0003591. The objective of this project was to develop a new class of solar concentrators with geometries and manufacturability that could significantly reduce the fully installed cost of the solar collector field for concentrated solar thermal power plants. The goal of the project was to achieve an aggressive cost target of $170/m2, a reduction of up to 50% in the total installed cost of a solar collector field as measured against the current industry benchmark of a conventional parabolic trough. The project plan, and the detailed activities conducted under the scope of the DOE Award project addressed all major drivers that affect solar collector costs. In addition to costs, the study also focused on evaluating technical performance of new collector architectures and compared them to the performance of the industry benchmark parabolic trough. The most notable accomplishment of this DOE award was the delivery of a full-scale integrated design, manufacturing and field installation solution for a new class of solar collector architecture which has been classified as the Bi-Planar Fresnel Collector (BPFC) and may be considered as a viable alternative to the conventional parabolic trough, as well as the conventional Fresnel collectors. This was in part accomplished through the design and development, all the way through fabrication and test validation of a new class of Linear Planar Fresnel Collector architecture. This architecture offers a number of key differentiating features which include a planar light-weight frame geometry with small mass-manufacturable elements utilizing flat mirror sections. The designs shows significant promise in reducing the material costs, fabrication costs, shipping costs, and on-site field installation costs compared to the benchmark parabolic trough, as well as the

  20. Optimized concentrating/passive tracking solar collector. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Sterne, K E; Johnson, A L; Grotheer, R H

    1979-01-01

    A concentrating solar collector having about half the material cost of other collectors with similar performance is described. The selected design is a Compound Parabolic Concentrator (CPC) which concentrates solar energy throughout the year without requiring realignment. Output is a fluid heated to 100/sup 0/C with good efficiency. The optical design of the reflector surface was optimized, yielding a 2.0:1 concentration ratio with a 60/sup 0/C acceptance angle and a low profile. Double glazing was chosen consisting of a polyester film outer glazing and an inner glazing of glass tubes around the absorbers. The selectively coated steel absorber tubes are connected in series with flexible plastic tubing. Much development effort went into the materials for the reflector subassembly. A laminate of metalized plastic film over plaster was chosen for the reflective surface. The reflector is rigidized by attaching filled epoxy header plates at each end. Aluminum side rails and an insulating back complete the structure. The finished design resulted in a material cost of $21.40 per square meter in production quantities. Performance testing of a prototype produced a 50% initial efficiency rating. This is somewhat lower than expected, and is due to materials and processes used in the prototype for the outer glazing, reflective surface and absorber coating. However, the efficiency curve drops only slightly with increasing temperature differential, showing the inherent advantage of the concentrator over flat plate collectors.

  1. Hybrid solar collector using nonimaging optics and photovoltaic components

    Science.gov (United States)

    Winston, Roland; Yablonovitch, Eli; Jiang, Lun; Widyolar, Bennett K.; Abdelhamid, Mahmoud; Scranton, Gregg; Cygan, David; Kozlov, Alexandr

    2015-08-01

    The project team of University of California at Merced (UC-M), Gas Technology Institute, and Dr. Eli Yablonovitch of University of California at Berkeley developed a novel hybrid concentrated solar photovoltaic thermal (PV/T) collector using nonimaging optics and world record single-junction Gallium arsenide (GaAs) PV components integrated with particle laden gas as thermal transfer and storage media, to simultaneously generate electricity and high temperature dispatchable heat. The collector transforms a parabolic trough, commonly used in CSP plants, into an integrated spectrum-splitting device. This places a spectrum-sensitive topping element on a secondary reflector that is registered to the thermal collection loop. The secondary reflector transmits higher energy photons for PV topping while diverting the remaining lower energy photons to the thermal media, achieving temperatures of around 400°C even under partial utilization of the solar spectrum. The collector uses the spectral selectivity property of Gallium arsenide (GaAs) cells to maximize the exergy output of the system, resulting in an estimated exergy efficiency of 48%. The thermal media is composed of fine particles of high melting point material in an inert gas that increases heat transfer and effectively stores excess heat in hot particles for later on-demand use.

  2. Coloured solar collectors. Phase II : from laboratory samples to collector prototypes. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Schueler, A.; Roecker, Ch.; Chambrier, E. de; Munari Probst, M.

    2007-07-01

    This illustrated final report for the Swiss Federal Office of Energy (SFOE) deals with the second phase of a project concerning the architectural integration of glazed solar collectors into the facades of buildings for heat production. The factors that limit the integration of photovoltaic panels in facades are discussed. The authors state that, for a convincing demonstration, sufficiently large samples and high quality levels are needed. The sol-gel deposition of the multi-layered coatings on A4-sized glass panes demonstrated in the laboratory by EPFL-LESO are discussed. The coatings produced exhibit a coloured reflection in combination with a high solar transmittance, a homogenous appearance, and are free of visible defects. Film hardening by UV exposure is discussed: This should result in the speeding up of the sol-gel process and thus save energy, thereby significantly reducing costs. Collaboration with industry is discussed in which full-scale glass panes are to be coated with novel multiple layers. The novel glazing is to be integrated into first prototype collectors. The manufacturing and test processes for the prototypes manufactured are discussed in detail.

  3. FLOW DISTRIBUTION IN A SOLAR COLLECTOR PANEL WITH HORIZONTAL ABSORBER STRIPS

    DEFF Research Database (Denmark)

    Fan, Jianhua; Shah, Louise Jivan; Furbo, Simon

    2007-01-01

    The objective of this work is to theoretically and experimentally investigate the flow and temperature distribution in a solar collector panel with an absorber consisting of horizontal strips. Fluid flow and heat transfer in the collector panel are studied by means of computational fluid dynamics...... (CFD) calculations. Further, experimental investigations of a 12.5 m² solar collector panel with 16 parallel connected horizontal fins are carried out. The flow distribution through the absorber is evaluated by means of temperature measurements on the backside of the absorber tubes. The measured...... collector fluid, and by increased collector tilt and inlet temperature, the flow distribution gets worse resulting in a decreased collector efficiency and an increased risk of boiling in the upper part of the collector panel. Keywords: Solar collector; Flow distribution; Computational Fluid Dynamics (CFD...

  4. The Effect of the Volume Flow rate on the Efficiency of a Solar Collector

    DEFF Research Database (Denmark)

    Fan, Jianhua; Shah, Louise Jivan; Furbo, Simon

    rates. Theoretically, a simplified model of the solar collector panel is built by means of the CFD (Computational Fluid Dynamics) code Fluent, where the geometry of the collector panel except the casing is fully modeled. Both lateral and longitudinal heat conduction in the absorber fins, the heat...... transfer from the absorber to the solar collector fluid and the heat loss from the absorber are considered. Flow and temperature distribution in the collector panel are investigated with buoyancy effect. Measurements are carried out with the solar collector panel. Collector efficiencies are measured......The flow distribution inside a collector panel with an area of 12.5 m² and with 16 parallel connected horizontal fins and the effect of the flow nonuniformity on the risk of boiling and on the collector efficiency have been theoretically and experimentally investigated for different volume flow...

  5. Bilinear reduced order approximate model of parabolic distributed solar collectors

    KAUST Repository

    Elmetennani, Shahrazed

    2015-07-01

    This paper proposes a novel, low dimensional and accurate approximate model for the distributed parabolic solar collector, by means of a modified gaussian interpolation along the spatial domain. The proposed reduced model, taking the form of a low dimensional bilinear state representation, enables the reproduction of the heat transfer dynamics along the collector tube for system analysis. Moreover, presented as a reduced order bilinear state space model, the well established control theory for this class of systems can be applied. The approximation efficiency has been proven by several simulation tests, which have been performed considering parameters of the Acurex field with real external working conditions. Model accuracy has been evaluated by comparison to the analytical solution of the hyperbolic distributed model and its semi discretized approximation highlighting the benefits of using the proposed numerical scheme. Furthermore, model sensitivity to the different parameters of the gaussian interpolation has been studied.

  6. Evaluation of Surface Slope Irregularity in Linear Parabolic Solar Collectors

    Directory of Open Access Journals (Sweden)

    F. Francini

    2012-01-01

    Full Text Available The paper describes a methodology, very simple in its application, for measuring surface irregularities of linear parabolic collectors. This technique was principally developed to be applied in cases where it is difficult to use cumbersome instruments and to facilitate logistic management. The instruments to be employed are a digital camera and a grating. If the reflector surface is defective, the image of the grating, reflected on the solar collector, appears distorted. Analyzing the reflected image, we can obtain the local slope of the defective surface. These profilometric tests are useful to identify and monitor the mirror portions under mechanical stress and to estimate the losses caused by the light rays deflected outside the absorber.

  7. Study and modeling of energy performance of a hybrid photovoltaic/thermal solar collector: Configuration suitable for an indirect solar dryer

    International Nuclear Information System (INIS)

    Slimani, Mohamed El Amine; Amirat, Madjid; Bahria, Sofiane; Kurucz, Ildikó; Aouli, M’heni; Sellami, Rabah

    2016-01-01

    Highlights: • The simulation results are in compliance with the experimental measurements indicated in the previous literature. • The accuracy of the numerical model is due to the presented energy analysis and also to the well-adopted correlations. • A comparative study between two solar photovoltaic/thermal air collectors was carried out. • The thermal efficiency of the analyzed hybrid collector increased by 30.85% compared to the basic configuration. • The air temperature supplied by a double-pass photovoltaic/thermal collector is very suitable for solar drying. - Abstract: In this paper, a configuration of photovoltaic-thermal hybrid solar collector embeddable in an indirect solar dryer system is studied. In the present structure of the solar photovoltaic/thermal air collector, the air goes through a double pass below and above the photovoltaic module. A system of electrical and thermal balance equations is developed and analyzed governing various electric and heat transfer parameters in the solar hybrid air collector. The numerical model planned for this study gives a good precision of results, which are close to the experimental ones (of previous literature), and makes it possible to have a good assessment of energy performance regarding the studied configuration (temperature, electric and thermal powers, electrical and thermal efficiencies, etc.). The numerical results show the energy effectiveness of this hybrid collector configuration and particularly its interesting use in an indirect solar dryer system that provides a more suitable air temperature for drying agricultural products. The values of the electrical, thermal and overall energy efficiencies reaches 10.5%, 70% and 90% respectively, with a mass flow rate of 0.0155 kg/s and weather data sample for the month of June in the Algiers site. The results presented in this study also reveal how important the effect of certain parameters and operating conditions on the performance of the hybrid

  8. Genesis Solar Wind Science Canister Components Curated as Potential Solar Wind Collectors and Reference Contamination Sources

    Science.gov (United States)

    Allton, J. H.; Gonzalez, C. P.; Allums, K. K.

    2016-01-01

    The Genesis mission collected solar wind for 27 months at Earth-Sun L1 on both passive and active collectors carried inside of a Science Canister, which was cleaned and assembled in an ISO Class 4 cleanroom prior to launch. The primary passive collectors, 271 individual hexagons and 30 half-hexagons of semiconductor materials, are described in. Since the hard landing reduced the 301 passive collectors to many thousand smaller fragments, characterization and posting in the online catalog remains a work in progress, with about 19% of the total area characterized to date. Other passive collectors, surfaces of opportunity, have been added to the online catalog. For species needing to be concentrated for precise measurement (e.g. oxygen and nitrogen isotopes) an energy-independent parabolic ion mirror focused ions onto a 6.2 cm diameter target. The target materials, as recovered after landing, are described in. The online catalog of these solar wind collectors, a work in progress, can be found at: http://curator.jsc.nasa.gov/gencatalog/index.cfm This paper describes the next step, the cataloging of pieces of the Science Canister, which were surfaces exposed to the solar wind or component materials adjacent to solar wind collectors which may have contributed contamination.

  9. Performance of nanofluids on heat transfer in a wavy solar collector

    African Journals Online (AJOL)

    user

    Solar technologies are broadly characterized as either passive solar or active solar depending on the way they capture, convert and distribute solar energy. Active solar techniques include the use of photovoltaic panels and solar thermal collectors to harness the energy. Passive solar techniques include orienting a building ...

  10. Standardized performance tests of collectors of solar thermal energy-a flat-plate collector with a single-tube serpentine flow distribution

    Science.gov (United States)

    Johnson, S.

    1976-01-01

    This preliminary data report gives basic test results of a flat-plate solar collector whose performance was determined in the NASA-Lewis solar simulator. The collector was tested over ranges of inlet temperatures, fluxes and coolant flow rates. Collector efficienty is correlated in terms of inlet temperature and flux level.

  11. Numerical and experimental investigation on a new type of compound parabolic concentrator solar collector

    International Nuclear Information System (INIS)

    Zheng, Wandong; Yang, Lin; Zhang, Huan; You, Shijun; Zhu, Chunguang

    2016-01-01

    Highlights: • A serpentine compound parabolic concentrator solar collector is proposed. • A mathematical model for the new collector is developed and verified by experiments. • The thermal efficiency of the collector can be up to 60.5% during the experiments. • The effects of key parameters on the thermal performance are mathematically studied. - Abstract: In order to improve the thermal efficiency, reduce the heat losses and achieve high freezing resistance of the solar device for space heating in cold regions, a new type of serpentine compound parabolic concentrator solar collector is presented in this paper, which is a combination of a compound parabolic concentrator solar collector and a flat plate solar collector. A detailed mathematical model for the new collector based on the analysis of heat transfer is developed and then solved by the software tool Matlab. The numerical results are compared with the experimental data and the maximum deviation is 8.07%, which shows a good agreement with each other. The experimental results show that the thermal efficiency of the collector can be as high as 60.5%. The model is used to predict the thermal performance of the new collector. The effects of structure and operating parameters on the thermal performance are mathematically discussed. The numerical and experimental results show that the new collector is more suitable to provide low temperature hot water for space heating in cold regions and the mathematical model will be much helpful in the designing and optimizing of the solar collectors.

  12. A heat pipe solar collector system for winter heating in Zhengzhou city, China

    Directory of Open Access Journals (Sweden)

    Zheng Hui-Fan

    2017-01-01

    Full Text Available A heat pipe solar collector system for winter heating is investigated both experimentally and theoretically. The hourly heat collecting capacity, water temperature and contribution rate of solar collector system based on Zhengzhou city typical sunshine are calculated. The study reveals that the heat collecting capacity and water temperature increases initially and then decreases, and the solar collector system can provide from 40% to 78% heating load for a 200 m2 villa with in Zhengzhou city from November to March.

  13. Design and installation package for the Sunmat Flat Plate Solar Collector

    Energy Technology Data Exchange (ETDEWEB)

    1978-03-01

    The information used in evaluating the design of the Sunmat Liquid Flat Plat Plate Solar Collector developed by Calmac Manufacturing Company is presented. Included in this package are the Subsystem Performance Specification, Installation, Operation and Maintenance Manuals, collector sizing guides, and detailed drawings of the single-glazed collector.

  14. Energy, economic and environmental analysis of metal oxides nanofluid for flat-plate solar collector

    International Nuclear Information System (INIS)

    Faizal, M.; Saidur, R.; Mekhilef, S.; Alim, M.A.

    2013-01-01

    Highlights: • By using nanofluid, smaller and compact solar collector can be produced. • The average value of 220 MJ embodied energy can be saved. • The payback period of using nanofluid solar collector is around 2.4 years. • Around 170 kg less CO 2 emissions in average for nanofluid solar collector. • Environmental damage cost is lower with the nanofluid based solar collector. - Abstract: For a solar thermal system, increasing the heat transfer area can increase the output temperature of the system. However, this approach leads to a bigger and bulkier collector. It will then increase the cost and energy needed to manufacture the solar collector. This study is carried out to estimate the potential to design a smaller solar collector that can produce the same desired output temperature. This is possible by using nanofluid as working fluid. By using numerical methods and data from literatures, efficiency, size reduction, cost and embodied energy savings are calculated for various nanofluids. From the study, it was estimated that 10,239 kg, 8625 kg, 8857 kg and 8618 kg total weight for 1000 units of solar collectors can be saved for CuO, SiO 2 , TiO 2 and Al 2 O 3 nanofluid respectively. The average value of 220 MJ embodied energy can be saved for each collector, 2.4 years payback period can be achieved and around 170 kg less CO 2 emissions in average can be offset for the nanofluid based solar collector compared to a conventional solar collector. Finally, the environmental damage cost can also be reduced with the nanofluid based solar collector

  15. Experience with building integrated solar collectors; Erfaring med bygningsintegrerte solfangere

    Energy Technology Data Exchange (ETDEWEB)

    Simonsen, Ingeborg; Time, Berit; Andresen, Inger

    2011-07-01

    The main objective of the research 'Zero Emission Buildings' ZEB is to develop products and solutions that provide buildings with zero greenhouse gas emissions associated with the production, operation and disposal. Can we make this happen must the building produce more energy than it needs to compensate for greenhouse gas emissions from the production of materials and the actual construction.To build up knowledge on experience with building integrated solar collectors in Norway, we have in this study made interviews with suppliers and manufacturers of solar collectors and some building owners. Since the focus is on climate shell, we have limited the study to include solar collectors to replace a part of the cladding or roofing. Construction upstairs roofing, outside facade or freestanding rack is not considered as building integrated in this context. The providers we have been in contact with appeals to slightly different parts of the market. This is reflected in the product's development, assembly and approach to the calculation of energy delivery. Overall, providers may offer a range of products suitable for both the professional and skilled carpenter, the interested 'man in the street' . The feedback we have received shows generally good experiences with the product and the installation. Because of the preliminary short operating periods of the investigated plants we have little data on energy supply from these plants. In summary, we can say that the knowledge and the products are available and it is up to use to use them.(Author)

  16. Flow distribution in a solar collector panel with horizontally inclined absorber strips

    DEFF Research Database (Denmark)

    Fan, Jianhua; Shah, Louise Jivan; Furbo, Simon

    2007-01-01

    The objective of this work is to theoretically and experimentally investigate the flow and temperature distribution in a solar collector panel with an absorber consisting of horizontally inclined strips. Fluid flow and heat transfer in the collector panel are studied by means of computational fluid...... dynamics (CFD) calculations. Further, experimental investigations of a 12.5 m(2) solar collector panel with 16 parallel connected horizontal fins are carried out. The flow distribution through the absorber is evaluated by means of temperature measurements on the backside of the absorber tubes. The measured...... rate, properties of solar collector fluid, solar collector fluid inlet temperature and collector tilt angle are shown. The flow distribution through the absorber fins is uniform if high flow rates are used. By decreased flow rate and decreased content of glycol in the glycol/water mixture used as solar...

  17. Fuzzy Universal Model Approximator for Distributed Solar Collector Field Control

    KAUST Repository

    Elmetennani, Shahrazed

    2014-07-01

    This paper deals with the control of concentrating parabolic solar collectors by forcing the outlet oil temperature to track a set reference. A fuzzy universal approximate model is introduced in order to accurately reproduce the behavior of the system dynamics. The proposed model is a low order state space representation derived from the partial differential equation describing the oil temperature evolution using fuzzy transform theory. The resulting set of ordinary differential equations simplifies the system analysis and the control law design and is suitable for real time control implementation. Simulation results show good performance of the proposed model.

  18. Nanoparticles Ni electroplating and black paint for solar collector applications

    OpenAIRE

    Nady, J.; Kashyout, A.B.; Ebrahim, Sh.; Soliman, M.B.

    2017-01-01

    A nanoparticles layer of bright nickel base was deposited on copper substrates using electrodeposition technique before spraying the paint. IR reflectance of the paint was found to be around 0.4 without bright nickel layer and the reflectance increased to 0.6 at a Ni layer thickness of 750 nm. The efficiency of the constructed solar collectors using black paint and black paint combined with bright nickel was found to be better than black paint individually. After aging tests under high temper...

  19. Design and Development of a Solar Thermal Collector with Single Axis Solar Tracking Mechanism

    OpenAIRE

    Theebhan Mogana; Long Chua Yaw; Tiong Tay Tee

    2016-01-01

    The solar energy is a source of energy that is abundant in Malaysia and can be easily harvested. However, because of the rotation of the Earth about its axis, it is impossible to harvest the solar energy to the maximum capacity if the solar thermal collector is placed fix to a certain angle. In this research, a solar thermal dish with single axis solar tracking mechanism that will rotate the dish according to the position of the sun in the sky is designed and developed, so that more solar ray...

  20. Economical judge possibility uses solar collectors to warm service water and heating

    Directory of Open Access Journals (Sweden)

    Lívia Bodonská

    2006-09-01

    Full Text Available The sun-heated water has been used from before fossil fuels started to determine the direction of our power consumption. This article is focused on the assessing of the use of solar energy as one of inexhaustible resources that has multiple uses, including hot water service systems. Heating is rendered through solar collectors that permit to transform solar energy to warm water. We divide solar collectors into various groups but in principle they are medium temperature collectors and low temperature collectors. The work is directed also on the solar collector market. In our case the market is just at its initial stage as this technology is little known and costs of collectors are rather high, compared to our conditions, on average, they may grow up to 100,000 Slovac crowns per a family house. Because it is the only investment and the costs of operation are minimum throughout the entire collectors lifetime, from the economic point of view, it is a rather advantageous investment. Solar collectors are used in heating and also in hot service water systems in family houses, where they permit to lower costs for the consumption of many kinds of energies. In the hot service water system, solar collectors permit to lower the consumption by almost 70 %. This way of using the solar energy is very prospective and in future it will be used in various sectors

  1. The effect of coupling a flat-plat collector on the solar still productivity

    International Nuclear Information System (INIS)

    Badran, O. O.; Al-Tahaineh, H. A.

    2006-01-01

    Experimental investigation to study the effect of coupling a flat plate solar collector on the productivity of solar stills was carried out. Other different parameters (i.e. water depth, direction of still, solar radiation) to enhance the productivity were also studied. Single slope solar still with mirrors fixed to its interior sides was coupled with a flat plate collector. It has been found that coupling of a solar collector with a still has increased the productivity by 56%. Also the increase of water depth has decreased the productivity, while the still productivity is found to be proportional to the solar radiation intensity.(Author)

  2. Experimental System of Solar Adsorption Refrigeration with Concentrated Collector.

    Science.gov (United States)

    Yuan, Z X; Li, Y X; Du, C X

    2017-10-18

    To improve the performance of solar adsorption refrigeration, an experimental system with a solar concentration collector was set up and investigated. The main components of the system were the adsorbent bed, the condenser, the evaporator, the cooling sub-system, and the solar collector. In the first step of the experiment, the vapor-saturated bed was heated by the solar radiation under closed conditions, which caused the bed temperature and pressure to increase. When the bed pressure became high enough, the bed was switched to connect to the condenser, thus water vapor flowed continually from the bed to the condenser to be liquefied. Next, the bed needed to cool down after the desorption. In the solar-shielded condition, achieved by aluminum foil, the circulating water loop was opened to the bed. With the water continually circulating in the bed, the stored heat in the bed was took out and the bed pressure decreased accordingly. When the bed pressure dropped below the saturation pressure at the evaporation temperature, the valve to the evaporator was opened. A mass of water vapor rushed into the bed and was adsorbed by the zeolite material. With the massive vaporization of the water in the evaporator, the refrigeration effect was generated finally. The experimental result has revealed that both the COP (coefficient of the performance of the system) and the SCP (specific cooling power of the system) of the SAPO-34 zeolite was greater than that of the ZSM-5 zeolite, no matter whether the adsorption time was longer or shorter. The system of the SAPO-34 zeolite generated a maximum COP of 0.169.

  3. Solar energy captured by a curved collector designed for architectural integration

    International Nuclear Information System (INIS)

    Rodríguez-Sánchez, D.; Belmonte, J.F.; Izquierdo-Barrientos, M.A.; Molina, A.E.; Rosengarten, G.; Almendros-Ibáñez, J.A.

    2014-01-01

    Highlights: • We present a new prototype of solar collector for architectural integration. • Equations of the solar radiation on a curved surface. • We compare the energy intercepted by the prototype with the energy intercepted by conventional collectors. • The prototype can be competitive compared with conventional collectors. - Abstract: In this paper we present a prototype for a new type of solar thermal collector designed for architectural integration. In this proposal, the conventional geometry of a flat solar thermal collector is changed to a curved geometry, to improve its visual impact when mounted on a building facade or roof. The mathematical equations for the beam and diffuse solar radiation received by a collector with this geometry are developed for two different orientations, horizontal and vertical. The performance of this curved prototype, in terms of solar radiation received, is compared with a conventional tilted-surface collector for different orientations in Madrid (Spain). The comparison is made for typical clear-sky days in winter and summer as well as for an entire year. The results demonstrate that the curved collector only receives between 12% and 25% less radiation than the conventional tilted-surface collectors when oriented horizontally, depending on the azimuth of the curved surface, although these percentages are reduced to approximately 50% when the collector is oriented vertically

  4. Progress of nanofluid application in solar collectors: A review

    International Nuclear Information System (INIS)

    Verma, Sujit Kumar; Tiwari, Arun Kumar

    2015-01-01

    Highlights: • Nanoparticles are more suited and adapt to enhance the performance of solar systems. • Extinction coefficient and refractive index of nanofluids are found higher. • Optimum range of volume fraction for which enhancement in heat transfer coefficient is maximum. • Overall response of specific heat capacity of nanofluids is highly anomalous. - Abstract: In recent times solar energy has attracted the attention of scientists to a great deal. On the surface, there are two reasons for it: primarily, the scientists are interested in it with the intent to innovating new devices and secondly, developing new methods to harness it. Miniaturization of devices and energy efficiency are the major focal domains around which new materials are being worked on. The design of solar system may get some basic changes, if the new materials get applied successfully. Albeit, the nanofluids are a comparatively recent innovation which exhibit enhanced heat absorbing and heat transport ability. This paper intends to reinforce the working of nanofluids applied on solar system in the light of works done earlier; it further also explores the variable performance of the solar-system with and without application of nano-fluids. This work has been segmented into two parts: the first part focuses on presenting the experimental and numerical results for the thermal conductivity, viscosity, specific heat and the heat transfer coefficient reported by several authors. The second part deals with the application of nanofluids on different types of solar systems: solar collectors, photovoltaic systems, and solar thermoelectric and energy storage system. A study of the works earlier done seems to be suggesting that the nanofluids have great potential to enhance the functioning of various thermal systems. The recent results of the application of nanofluids in PV/T systems too have been consolidating. It can be safely assumed further that it might enhance the overall performance of the

  5. Annual measured and simulated thermal performance analysis of a hybrid solar district heating plant with flat plate collectors and parabolic trough collectors in series

    DEFF Research Database (Denmark)

    Tian, Zhiyong; Perers, Bengt; Furbo, Simon

    2017-01-01

    in large solar heating plants for a district heating network, a hybrid solar collector field with 5960 m2 flat plate collectors and 4039 m2 parabolic trough collectors in series was constructed in Taars, Denmark. The design principle is that the flat plate collectors preheat the return water from...... the district heating network to about 70 °C and then the parabolic trough collectors would heat the preheated water to the required supply temperature of the district heating network. Annual measured and simulated thermal performances of both the parabolic trough collector field and the flat plate collector...... field are presented in this paper. The thermal performance of both collector fields with weather data of a Design Reference Year was simulated to have a whole understanding of the application of both collectors under Danish climate conditions as well. These results not only can provide a design basis...

  6. Solar radiation for sea-water desalination and electric power generation via vacuum solar collectors

    International Nuclear Information System (INIS)

    Mottinelli, L.; Reali, M.; El-Nashar, A.M.; Giusiano, F.; Vigotti, R.

    1996-01-01

    The present report concerns the energetic potential of vacuum solar which are rather versatile and efficient devices for converting solar energy into thermal energy. Two main energetic applications have been analysed: the first one for a solar sea water desalination plant which has been operated in Abu Dhabi for the past ten years, the other for a conceptual solar thermoelectric-power plant having a fair thermodynamic efficiency (15-20%). A simple technology for the manufacture of vacuum solar collectors in a standard mechanical shop is being developed in collaboration between ENEL Sp A (DSR-CRIS, Milano) and WED (Abu Dhabi). Such technology should have an important economy-saving potential per se and would also make repair and substitution operations simple enough for the actual operators of the vacuum solar collector system without any need of external assistance. The technic-operative-economical features of the Abu Dhabi solar desalination plant suggest that the use novel simplified vacuum solar collectors could have a considerable technic economical potential. The analysis of the conceptual solar thermo-electric-power plant focuses on its general layout and singles out key technological issues which ought to be addressed in an overall feasibility study. 5 figs., 3 tabs

  7. A numerical model to evaluate the flow distribution in a large solar collector field

    DEFF Research Database (Denmark)

    Bava, Federico; Dragsted, Janne; Furbo, Simon

    2017-01-01

    This study presents a numerical model to evaluate the flow distribution in a large solar collector field, with solar collectors connected both in series and in parallel. The boundary conditions of the systems, such as flow rate, temperature, fluid type and layout of the collector field can...... be easily changed in the model. The model was developed in Matlab and the calculated pressure drop and flow distribution were compared with measurements from a solar collector field. A good agreement between model and measurements was found. The model was then used to study the flow distribution...... in different conditions. Balancing valves proved to be an effective way to achieve uniform flow distribution also in conditions different from those for which the valves were regulated. For small solar collector fields with limited number of collector rows connected in parallel, balancing valves...

  8. Numerical characterisation of one-step and three-step solar air heating collectors used for cocoa bean solar drying.

    Science.gov (United States)

    Orbegoso, Elder Mendoza; Saavedra, Rafael; Marcelo, Daniel; La Madrid, Raúl

    2017-12-01

    In the northern coastal and jungle areas of Peru, cocoa beans are dried using artisan methods, such as direct exposure to sunlight. This traditional process is time intensive, leading to a reduction in productivity and, therefore, delays in delivery times. The present study was intended to numerically characterise the thermal behaviour of three configurations of solar air heating collectors in order to determine which demonstrated the best thermal performance under several controlled operating conditions. For this purpose, a computational fluid dynamics model was developed to describe the simultaneous convective and radiative heat transfer phenomena under several operation conditions. The constructed computational fluid dynamics model was firstly validated through comparison with the data measurements of a one-step solar air heating collector. We then simulated two further three-step solar air heating collectors in order to identify which demonstrated the best thermal performance in terms of outlet air temperature and thermal efficiency. The numerical results show that under the same solar irradiation area of exposition and operating conditions, the three-step solar air heating collector with the collector plate mounted between the second and third channels was 67% more thermally efficient compared to the one-step solar air heating collector. This is because the air exposition with the surface of the collector plate for the three-step solar air heating collector former device was twice than the one-step solar air heating collector. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. Temperature comparison of different reflective surfaces of a solar thermal collector

    Science.gov (United States)

    Koh, Yit Yan; Chua, Yaw Long; Chin, Kiat Keong

    2017-09-01

    With the rapid depletion of fossil fuels, the search for application of alternative energy sources becomes more important than ever before. Solar energy has been identified as one of the major renewable energy that will contribute to power generation is years to come. There are two major categories of solar energy applications. Solar thermal collector is one of it. This paper presents an investigation on the effect of different reflecting surfaces on solar thermal collector. Three different reflective surfaces were applied on the surface of the solar thermal collector. Data was collected and analyzed. From the results, the aluminum mirror sheet performed best.

  10. Experimental Validation and Model Verification for a Novel Geometry ICPC Solar Collector

    DEFF Research Database (Denmark)

    Perers, Bengt; Duff, William S.; Daosukho, Jirachote

    at the various specified incident angles provide model verification for the investigation into causes of ray attenuation and provide accounts for rays that escape. Two fourteen tube modules were tested on Sandia National Laboratory’s two-axis tracking (AZTRAK) platform. By adjusting the tracking of the platform...... at the corresponding specified incident angles are compared to the Sandia results. A 100 m2 336 Novel ICPC evacuated tube solar collector array has been in continuous operation at a demonstration project in Sacramento California since 1998. Data from the initial operation of the array are used to further validate...

  11. Effect of radiation on convective flow in a tilted solar collector filled ...

    African Journals Online (AJOL)

    alumina nanofluid. ... International Journal of Engineering, Science and Technology ... The effect of radiation on natural convective flow inside a solar collector having a flat-plate cover and a sine-wave absorber is analyzed numerically. The solar ...

  12. Solar radiation and thermal performance of solar collectors for Denmark

    DEFF Research Database (Denmark)

    Dragsted, Janne; Furbo, Simon

    This report describes the part of the EUDP project “EUDP 11-l, Solar Resource Assessment in Denmark”, which is carried out at Department of Civil Engineering, Technical University of Denmark.......This report describes the part of the EUDP project “EUDP 11-l, Solar Resource Assessment in Denmark”, which is carried out at Department of Civil Engineering, Technical University of Denmark....

  13. Nanofluid optical property characterization: towards efficient direct absorption solar collectors

    Directory of Open Access Journals (Sweden)

    Otanicar Todd

    2011-01-01

    Full Text Available Abstract Suspensions of nanoparticles (i.e., particles with diameters < 100 nm in liquids, termed nanofluids, show remarkable thermal and optical property changes from the base liquid at low particle loadings. Recent studies also indicate that selected nanofluids may improve the efficiency of direct absorption solar thermal collectors. To determine the effectiveness of nanofluids in solar applications, their ability to convert light energy to thermal energy must be known. That is, their absorption of the solar spectrum must be established. Accordingly, this study compares model predictions to spectroscopic measurements of extinction coefficients over wavelengths that are important for solar energy (0.25 to 2.5 μm. A simple addition of the base fluid and nanoparticle extinction coefficients is applied as an approximation of the effective nanofluid extinction coefficient. Comparisons with measured extinction coefficients reveal that the approximation works well with water-based nanofluids containing graphite nanoparticles but less well with metallic nanoparticles and/or oil-based fluids. For the materials used in this study, over 95% of incoming sunlight can be absorbed (in a nanofluid thickness ≥10 cm with extremely low nanoparticle volume fractions - less than 1 × 10-5, or 10 parts per million. Thus, nanofluids could be used to absorb sunlight with a negligible amount of viscosity and/or density (read: pumping power increase.

  14. Thermal performance of an open thermosyphon using nanofluid for evacuated tubular high temperature air solar collector

    International Nuclear Information System (INIS)

    Liu, Zhen-Hua; Hu, Ren-Lin; Lu, Lin; Zhao, Feng; Xiao, Hong-shen

    2013-01-01

    Highlights: • A novel solar air collector with simplified CPC and open thermosyphon is designed and tested. • Simplified CPC has a much lower cost at the expense of slight efficiency loss. • Nanofluid effectively improves thermal performance of the above solar air collector. • Solar air collector with open thermosyphon is better than that with concentric tube. - Abstract: A novel evacuated tubular solar air collector integrated with simplified CPC (compound parabolic concentrator) and special open thermosyphon using water based CuO nanofluid as the working fluid is designed to provide air with high and moderate temperature. The experimental system has two linked panels and each panel includes an evacuated tube, a simplified CPC and an open thermosyphon. Outdoor experimental study has been carried out to investigate the actual solar collecting performance of the designed system. Experimental results show that air outlet temperature and system collecting efficiency of the solar air collector using nanofluid as the open thermosyphon’s working fluid are both higher than that using water. Its maximum air outlet temperature exceeds 170 °C at the air volume rate of 7.6 m 3 /h in winter, even though the experimental system consists of only two collecting panels. The solar collecting performance of the solar collector integrated with open thermosyphon is also compared with that integrated with common concentric tube. Experimental results show that the solar collector integrated with open thermosyphon has a much better collecting performance

  15. EXPERIMENTAL RESEARCH OF THE INFLUENCE OF VARIOUS TYPES OF SOLAR COLLECTORS FOR PERFORMANCE SOLAR DESALINATION PLANT

    Directory of Open Access Journals (Sweden)

    Rakhmatulin I.R.

    2014-04-01

    Full Text Available The article discusses the possibility of using renewable energy for water purification. Results of analysis of a preferred energy source for a water purification using installed in places where fresh water shortages and a lack of electrical energy. The possibility of desalination of salt water using solar energy for regions with temperate climate. Presented desalination plant working on energy vacuum solar collectors, principles of action developed by the desalination plant. The experimental results of a constructed distiller when working with vacuum glass tubes and vacuum tubes with copper core inside. Conclusions about the possibility of using solar collectors for water desalination, are tips and tricks to improve the performance of solar desalination plant.

  16. Slope Error Measurement Tool for Solar Parabolic Trough Collectors: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Stynes, J. K.; Ihas, B.

    2012-04-01

    The National Renewable Energy Laboratory (NREL) has developed an optical measurement tool for parabolic solar collectors that measures the combined errors due to absorber misalignment and reflector slope error. The combined absorber alignment and reflector slope errors are measured using a digital camera to photograph the reflected image of the absorber in the collector. Previous work using the image of the reflection of the absorber finds the reflector slope errors from the reflection of the absorber and an independent measurement of the absorber location. The accuracy of the reflector slope error measurement is thus dependent on the accuracy of the absorber location measurement. By measuring the combined reflector-absorber errors, the uncertainty in the absorber location measurement is eliminated. The related performance merit, the intercept factor, depends on the combined effects of the absorber alignment and reflector slope errors. Measuring the combined effect provides a simpler measurement and a more accurate input to the intercept factor estimate. The minimal equipment and setup required for this measurement technique make it ideal for field measurements.

  17. Nanoparticles Ni electroplating and black paint for solar collector applications

    Directory of Open Access Journals (Sweden)

    J. El Nady

    2016-06-01

    Full Text Available A nanoparticles layer of bright nickel base was deposited on copper substrates using electrodeposition technique before spraying the paint. IR reflectance of the paint was found to be around 0.4 without bright nickel layer and the reflectance increased to 0.6 at a Ni layer thickness of 750 nm. The efficiency of the constructed solar collectors using black paint and black paint combined with bright nickel was found to be better than black paint individually. After aging tests under high temperature, Bright nickel improved the stability of the absorber paint. The collector optical gain FR(τα was lowered by 24.7% for the commercial paint and lowered by 19.3% for the commercial paint combined with bright nickel. The overall heat loss FR(UL was increased by 3.3% for the commercial paint and increased by 2.7% for the commercial paint combined with bright nickel after the temperature aging test.

  18. Hybrid photovoltaic–thermal solar collectors dynamic modeling

    International Nuclear Information System (INIS)

    Amrizal, N.; Chemisana, D.; Rosell, J.I.

    2013-01-01

    Highlights: ► A hybrid photovoltaic/thermal dynamic model is presented. ► The model, once calibrated, can predict the power output for any set of climate data. ► The physical electrical model includes explicitly thermal and irradiance dependences. ► The results agree with those obtained through steady-state characterization. ► The model approaches the junction cell temperature through the system energy balance. -- Abstract: A hybrid photovoltaic/thermal transient model has been developed and validated experimentally. The methodology extends the quasi-dynamic thermal model stated in the EN 12975 in order to involve the electrical performance and consider the dynamic behavior minimizing constraints when characterizing the collector. A backward moving average filtering procedure has been applied to improve the model response for variable working conditions. Concerning the electrical part, the model includes the thermal and radiation dependences in its variables. The results revealed that the characteristic parameters included in the model agree reasonably well with the experimental values obtained from the standard steady-state and IV characteristic curve measurements. After a calibration process, the model is a suitable tool to predict the thermal and electrical performance of a hybrid solar collector, for a specific weather data set.

  19. Solar assisted heat pump on air collectors: A simulation tool

    Energy Technology Data Exchange (ETDEWEB)

    Karagiorgas, Michalis; Galatis, Kostas; Tsagouri, Manolis [Department of Mechanical Engineering Educators, ASPETE, N. Iraklio, GR 14121 (Greece); Tsoutsos, Theocharis [Environmental Engineering Dept., Technical University of Crete, Technical University Campus, GR 73100, Chania (Greece); Botzios-Valaskakis, Aristotelis [Centre for Renewable Energy Sources (CRES), 19th km Marathon Ave., GR 19001, Pikermi (Greece)

    2010-01-15

    The heating system of the bioclimatic building of the Greek National Centre for Renewable Energy Sources (CRES) comprises two heating plants: the first one includes an air source heat pump, Solar Air Collectors (SACs) and a heat distribution system (comprising a fan coil unit network); the second one is, mainly, a geothermal heat pump unit to cover the ground floor thermal needs. The SAC configuration as well as the fraction of the building heating load covered by the heating plant are assessed in two operation modes; the direct (hot air from the collectors is supplied directly to the heated space) and the indirect mode (warm air from the SAC or its mixture with ambient air is not supplied directly to the heated space but indirectly into the evaporator of the air source heat pump). The technique of the indirect mode of heating aims at maximizing the efficiency of the SAC, saving electrical power consumed by the compressor of the heat pump, and therefore, at optimizing the coefficient of performance (COP) of the heat pump due to the increased intake of ambient thermal energy by means of the SAC. Results are given for three research objectives: assessment of the heat pump efficiency whether in direct or indirect heating mode; Assessment of the overall heating plant efficiency on a daily or hourly basis; Assessment of the credibility of the suggested simulation model TSAGAIR by comparing its results with the TRNSYS ones. (author)

  20. Experimental investigations of the performance of a solar air collector with latent heat thermal storage integrated with the solar absorber

    Directory of Open Access Journals (Sweden)

    Hejcik J.

    2013-04-01

    Full Text Available The paper deals with experimental investigations of the performance of a solar air collector with latent heat thermal storage integrated with the solarabsorber. The main purpose of heat storage in solar thermal systems is to store heat when the supply of solar heat exceeds demand and release it when otherwise. A number of heat storage materials can be used for this purpose; the phase change materials among them. Short-term latent heat thermal storage integrated with the solar absorber can stabilize the air temperature at the outlet of the collector on cloudy days when solar radiation intensity incident on a solar collector fluctuates significantly. Two experimental front-and-back pass solar air collectors of the same dimensions have been built for the experimental investigations. One collector had a “conventional” solar absorber made of a metal sheet while the solar absorber of the other collector consisted of containers filled with organic phase change material. The experimental collectors were positioned side by side during the investigations to ensure the same operating conditions (incident solar radiation, outdoor temperature.

  1. Development of an alternative low-cost solar collector working at medium temperature (150 - 250°C)

    Science.gov (United States)

    Vidal, Frédéric; Chandez, Bertrand; Albert, Raphael

    2017-06-01

    Within the subtask 11.1.1 of the European project STAGE-STE, the CEA is in charge of the development of an alternative low-cost collector working at medium temperature (150-250 °C). PTC are installed in a small glasshouse in order to decrease the steel mass of the solar field. After a brief background of alternative PTC construction, characteristics and advantages of such a collector are presented and PTC arrangement performance (axis orientation, tilt angle) are discussed. Then, some mechanical studies are detailed and three prototypes module design are presented as well as their optical qualification.

  2. Energy performance of water hybrid PV/T collectors applied to combisystems of Direct Solar Floor type

    Energy Technology Data Exchange (ETDEWEB)

    Fraisse, G.; Johannes, K. [Laboratoire Optimisation de la Conception et Ingenierie de l' Environnement, Ecole Superieure d' Ingenieurs de Chambery, Campus Scientifique Savoie Technolac, 73376 Le Bourget du Lac Cedex (France); Menezo, C. [Centre de Thermique de Lyon, Domaine Scientifique de La Doua, Bat. Freyssinet, 20, Avenue A. Einstein, 69621 Villeurbanne Cedex (France)

    2007-11-15

    The integration of photovoltaic (PV) modules in buildings allows one to consider a multifunctional frame and then to reduce the cost by substitution of components. In order to limit the rise of the cell operating temperature, a photovoltaics/thermal (PV/T) collector combines a solar water heating collector and PV cells. The recovered heat energy can be used for heating systems and domestic hot water. A combination with a Direct Solar Floor is studied. Its low operating temperature level is appropriate for the operating conditions of the mono- or poly-crystalline photovoltaic modules which are selected in that study. However, for a system including a glass covered collector and localised in Macon area in France, we show that the annual photovoltaic cell efficiency is 6.8% which represents a decrease of 28% in comparison with a conventional non-integrated PV module of 9.4% annual efficiency. This is obviously due to a temperature increase related to the cover. On the other hand, we show that without a glass cover, the efficiency is 10% which is 6% better than a standard module due to the cooling effect. Moreover, in the case of a glazed PV/T collector with a conventional control system for Direct Solar Floor, the maximum temperature reached at the level of the PV modules is higher than 100{sup o}C. This is due to the oversize of the collectors during the summer when the heating needs are null, i.e. without a heated swimming pool for example. This temperature level does not allow the use of EVA resin (ethylene vinyl acetate) in PV modules due to strong risks of degradation. The current solution consists of using amorphous cells or, if we do not enhance the thermal production, uncovered PV/T collector. Further research led to water hybrid PV/T solar collectors as a one-piece component, both reliable and efficient, and including the thermal absorber, the heat exchanger and the photovoltaic functions. (author)

  3. Low-cost evacuated-tube solar collector appendices. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Beecher, D.T.

    1980-05-31

    A low cost solar heat energy collector module and array has been designed using the evacuated tube, selective absorber, air cooled concept. Glass tubing as used in fluorescent lamps with automatic sealing methods is a key feature of the evacuated tube design. A molded fiber glass concentrating reflector panel and sheet metal header assembly are proposed. Major design problems involved included the cost of materials and labor, thermal expansion and distortion problems, high stagnation and operating temperatures, isolation, thermal efficiency, sealing, joining, air pressure drop, and weight of the preassembled module. A cost of less than $5 per active square foot of collecting surface has been estimated for materials and labor of the module and its mounting frame.

  4. Method of forming oxide coatings. [for solar collector heating panels

    Science.gov (United States)

    Mcdonald, G. E. (Inventor)

    1983-01-01

    This invention is concerned with an improved plating process for covering a substrate with a black metal oxide film. The invention is particularly directed to making a heating panel for a solar collector. A compound is electrodeposited from an aqueous solution containing cobalt metal salts onto a metal substrate. This compound is converted during plating into a black, highly absorbing oxide coating which contains hydrated oxides. This is achieved by the inclusion of an oxidizing agent in the plating bath. The inclusion of an oxidizing agent in the plating bath is contrary to standard electroplating practice. The hydrated oxides are converted to oxides by treatment in a hot bath, such as boiling water. An oxidizing agent may be added to the hot liquid treating bath.

  5. Tårs 10000 m2 CSP + Flat Plate Solar Collector Plant - Cost-Performance Optimization of the Design

    DEFF Research Database (Denmark)

    Perers, Bengt; Furbo, Simon; Tian, Zhiyong

    2016-01-01

    , was established. The optimization showed that there was a synergy in combining CSP and FP collectors. Even though the present cost per m² of the CSP collectors is high, the total energy cost is minimized by installing a combination of collectors in such solar heating plant. It was also found that the CSP......A novel solar heating plant with Concentrating Solar Power (CSP) collectors and Flat Plate (FP) collectors has been put into operation in Tårs since July 2015. To investigate economic performance of the plant, a TRNSYS-Genopt model, including a solar collector field and thermal storage tank...

  6. Convective drying of chilies using a concentrating solar collector

    International Nuclear Information System (INIS)

    Hanif, M.; Khattak, M.K.; Aamir, M.

    2015-01-01

    A concentrating solar collector was developed for convective drying of green chilies by providing optimum drying environment. A temperature in the range of 45-65 degree C and relative humidity of less than 10% was observed during the drying period provided by the solar collector from 9.00 am to 5.00 pm. Different levels of drying temperature and air mass flow rates were tested to find their effect on drying time of the chilies. The experiment was laid out as a randomized complete block design with a factorial arrangement of the treatments consisting of 3 levels of temperature and 3 levels of air mass flow rate, replicated 3 times. Drying temperature and air mass flow rates effected the drying time significantly. The means comparison showed that minimum drying time of 17.96 h was recorded at high temperature of 65 degree C followed by a drying time of 20.27 and 21.43 h at temperatures of 55 and 45 degree C. The means of air mass flow rates showed that minimum drying time of 18.49 h was noted at high air mass flow rate of 3.50 kg min-1 followed by 20.32 and 20.86 h at air mass flow rates of 1.5 and 2.30 kg min-l. Chilies dried at temperature of 65 degree C and air mass flow rate of 3.5 kg min-1 showed an average drying rate of 0.02 g(H20)hrl cm-2as compared to the slow drying rates at 55 and 45 degree C. It was concluded that chilies must be dried at high temperature and high air mass flow rates to get on time quality dried chilies. (author)

  7. Purpose of neuronal method for modeling of solar collector

    Energy Technology Data Exchange (ETDEWEB)

    Salah, Hanini; Moussa, Cherif Si [LBMPt, Universite Yahia Fares de Medea, Quartier Ain D' heb, 2600, Medea (Algeria); Hamid, Abdi [SEEs/MS, B.P. 478, Route de Reggane, Adrar (Algeria); Tariq, Omari [LBMPT, Universite Yahia Fares de Medea, Quartier Ain D' Heb, 2600, Medea (Algeria); SEES/MS, B.P. 478, Route de Reggane, Adrar (Algeria); Unite de developpement des equipments solaires, Bou-Ismail, Tipaza (Algeria)

    2012-07-01

    Artificial Neural Networks (ANN) are widely accepted as a technology offering an alternative way to tackle complex and ill-defined problems. They have been used in diverse applications and have shown to be particularly effective in system identification and modeling as they are fault tolerant and can learn from examples. On the other hand, ANN are able to deal with non-linear problems and once trained can perform prediction at high speed. The objective of this work is the characterization of the integrated collector-storage solar water heater (ICSSWH) by the determination of the day time thermal (and optical) properties, and Night time heat loss coefficient with experimental temperatures, and predictive temperatures by (ANN). Because of that, an ANN has been trained using data for three types of systems, all employing the same collector panel under varying weather conditions. In this way the network was trained to accept and handle a number of unusual cases. The data presented as input were, the working systems (day or night), the type of system, the year, the month, the day, the time, the ambient air temperature, and the solar radiation. The network output is the temperature of the four tanks of storage unit. The correlations coefficients (R2-value) obtained for the training data set was equal to 0.997, 0.998, 0.998, and 0.996 for the four temperatures of each tank. The results obtained in this work indicate that the proposed method can successfully be used for the characterization of the ICSSWH.

  8. The UPM high temperature solar collector current status

    International Nuclear Information System (INIS)

    Mahdi Abdul Wahab; Mohd Yusof Sulaiman; Azmi Zakaria

    2000-01-01

    The high temperature solar energy research at Universiti Putra Malaysia (UPM) is an attempt to study the merits of the fixed aperture optics collector for the equatorial region using the concept of the fixed mirror distributed focus (FMDF). The general objective is to look for an alternative source of clean energy and a practical method of converting this energy to usable form for the projected industrialisation program of the country. The FMDF uses a stationary hemisphere bowl to capture the solar irradiance. The UPM bowl has a rim angle of 120 0 with radius of curvature of 27.9 m. This corresponds to an aperture diameter of 48 m and submerges 5.1 m in the ground. The bowl will later be tiled with 2446 square meters of mirror to form a spherical shape. And therefore will be able to collect about 1 MW of solar irradiance at the conical focus formed along the direction of the radius (high concentrated region) which then can be harnessed by different means. In this paper, we will report the current status and future works of the project, under construction at the site. We anticipate that the project will be completed and operated by the year 2000. (Author)

  9. Solar Still Coupled With Solar Collector and Storage Tank

    OpenAIRE

    Rajesh, A. M.; Bharath, K. N.

    2010-01-01

    Acute shortage of good, clean drinking water is a major problem for most developing countries of the world. In most cases, ponds, streams, wells and rivers are often polluted that they are unsafe for direct use as drinking water >.Often water sources are brackish and or contain harmful bacteria. Therefore cannot be used for drinking .In addition there are many coastal locations where sea water is abundant but potable water is not available. Solar distillation is one of the important methods o...

  10. Experimental evaluation of flat plate solar collector using nanofluids

    International Nuclear Information System (INIS)

    Verma, Sujit Kumar; Tiwari, Arun Kumar; Chauhan, Durg Singh

    2017-01-01

    Highlights: • Solar collectors are special kind of heat exchangers. • Particle concentration is important parameter for thermal conductivity of nanofluid. • Rise of Bejan number indicates systems qualitative response. • Multi walled carbon nanotube is best performing. - Abstract: The present analysis focuses on a wide variety of nanofluids for evaluating performance of flat plate solar collector in terms of various parameters as well as in respect of energy and exergy efficiency. Also, based on our experimental findings on varying mass flow rate, the present investigation has been conducted with optimum particle volume concentration. Experiments indicate that for ∼0.75% particle volume concentration at a mass flow rate of 0.025 kg/s, exergy efficiency for Multi walled carbon nanotube/water nanofluid is enhanced by 29.32% followed by 21.46%, 16.67%, 10.86%, 6.97% and 5.74%, respectively for Graphene/water, Copper Oxide water, Aluminum Oxide/water, Titanium oxide/water, and Silicon Oxide/water respectively instead of water as the base fluid. Entropy generation, which is a drawback, is also minimum in Multiwalled carbon nanotube/water nanofluids. Under the same thermophysical parameters, the maximum drop in entropy generation can be observed in Multiwalled carbon nanotube/water, which is 65.55%, followed by 57.89%, 48.32%, 36.84%, 24.49% and 10.04%, respectively for graphene/water, copper oxide/water, Aluminum/water, Titanium Oxide /water, and Silicon oxide /water instead of water as the base fluid. Rise of Bejan number towards unity emphasizes improved system performance in terms of efficient conversion of the available energy into useful functions. The highest rise in energy efficiency of a collector has been recorded in Multiwalled carbon nanotube/water, which is 23.47%, followed by 16.97%, 12.64%, 8.28%, 5.09% and 4.08%, respectively for graphene/water, Copper oxide/water, Aluminum oxide/water, Titanium oxide /water, and Silicon oxide/water instead of

  11. Solar collector design with respect to moisture problems

    DEFF Research Database (Denmark)

    Holck, Ole; Svendsen, Svend; Brunold, Stefan

    2003-01-01

    Humidity inside the collectors is one factor that can be minimised to keep the most favourable microclimatic condition for the internal materials of the collector. This microclimate inside the collector is an important factor in determining the service lifetime of an absorber coating. During the ...

  12. Experimental investigation of tri-functional photovoltaic/thermal solar collector

    International Nuclear Information System (INIS)

    Ji, Jie; Guo, Chao; Sun, Wei; He, Wei; Wang, Yanqiu; Li, Guiqiang

    2014-01-01

    Highlights: • A design of tri-functional photovoltaic/thermal solar collector is proposed. • The performance of tri-functional PV/T collector is investigated and compared. • The tri-functional PV/T collector is flexible to different working modes and variable seasons. - Abstract: Photovoltaic/thermal (PV/T) solar collectors can provide electric power and thermal energy simultaneously. Either PV/T water collectors or PV/T air collectors can be left unused in some seasons because of the freezing problem of water and seasonal demand of hot air. In this paper, a novel design of tri-functional PV/T solar collector was proposed. The collector can work in PV/water-heating mode or PV/air-heating mode according to the seasonal requirements. Experiments were conducted in different working modes under variable conditions to evaluate the performance of collector. The results show that the daily thermal efficiency achieved 46.0% with the electrical efficiency of 10.2% in PV/air-heating mode. The temperature increase of air reached 20 °C with the flow rate of 0.033 kg/s on a sunny day. The instantaneously thermal efficiency at zero reduced temperature were 37.4% and 44.3% as the air flow rate was 0.026 kg/s and 0.032 kg/s respectively. In PV/water-heating mode, the thermal efficiency of the collector was 56.6% at zero reduced temperature, and the daily thermal efficiency of the system was around 36.0%. Compared with solar collectors presented by other authors, the tri-functional PV/T collector is able to operate efficiently in various conditions

  13. Converting PETAL, the 25m solar collector, into an astronimcal research facility

    Science.gov (United States)

    Ribak, Erez N.; Laor, Ari; Faiman, David; Biyukov, Sergy; Brosch, Noah

    2003-02-01

    We propose to modify the solar collector PETAL (Photon Energy Transformation &Astrophysics Laboratory) for astronomy. The mirror is a segmented parabolic dish collector, which has a relatively poor imaging quality. The conversion can be done by either of two principal methods: (1) phasing the surface of the collector itself or significant sections thereof; (2) transforming the structure into an optical interferometer by mounting small telescopes around its rim, and using fiber optics to combine the light at a common focus.

  14. A high absorbance material for solar collectors' applications

    International Nuclear Information System (INIS)

    Oliva, A I; Maldonado, R D; Díaz, E A; Montalvo, A I

    2013-01-01

    In this work, we proposed a low cost material to be used as an excellent absorber for solar collectors, to increase its thermal efficiency by the high capacity to absorb solar radiation. The material, known as 'smoke black' (soot) can be obtained by the incomplete combustion of organic materials, such as the oxygen-acetylene, paraffin, or candles. A comparative analysis between the optical properties (reflectance, absorbance, and emissivity) measured on three covered copper surfaces (without paint, with a commercial matte black paint, and with smoke black) shows amazing optical results for the smoke black. Reflectance values of the smoke black applied over copper surfaces improves 56 times the values obtained from commercial black paints. High values of emissivity (E=0.9988) were measured on the surface covered with smoke black by spectrophotometry in the UV-VIS range, which represents about 7% of increment as compared with the value obtained for commercial black paints (E=0.938). The proposed high absorbance material can be easily applied on any kind of surfaces at low cost.

  15. Enhanced heat transfer using oscillatory flows in solar collectors

    Energy Technology Data Exchange (ETDEWEB)

    Lambert, A.A.; Cuevas, S.; Rio, J.A. del [Centro de Investigacion en Energia, UNAM, A.P. 34, 62580 Temixco, Mor. (Mexico)

    2006-10-15

    In this work, we propose the use of oscillatory laminar flows to enhance the transfer of heat from solar collectors. The idea is to explore the possibility of transferring the heat collected from a solar device to a storage tank by means of a zero-mean oscillating fluid contained in a tube. This method takes advantage of the fact that the effective thermal diffusivity of a fluid in oscillatory motion is several orders of magnitude higher than the fluid molecular diffusivity. Therefore, the axial transport of heat along the tube is substantially higher when the fluid oscillates than when the fluid is static. Also, preliminary estimations show a dramatic heat transfer enhancement using oscillatory flows compared with the forced convection of heat by standard unidirectional flows. We explore the behavior of the effective thermal diffusivity using both Newtonian and viscoelastic fluids. For the Newtonian fluid a single maximum value of this quantity is exhibited for a given oscillation frequency. In contrast, several maxima for different resonant frequencies are observed for the viscoelastic fluid. Further, the absolute maximum of the enhanced thermal diffusivity for the viscoelastic fluid is several orders of magnitude larger than that of the Newtonian fluid. (author)

  16. On the Influence of Collector Size on the Solar Chimneys Performance

    Directory of Open Access Journals (Sweden)

    Al-Azawiey Sundus S.

    2017-01-01

    Full Text Available Performance of solar chimney power plant system is highly influenced by the design geometries. The collector size is logically enhances the solar chimney performance, but the trend of enhancement is not yet investigated. In the present work, experimental and numerical investigations have been carried out to ascertain, in terms of qualitative and quantitative evaluation, the effect of the collector diameter. Daily thermal efficiency has been determined at four different collector diameter. Two different collector diameters, 3.0 and 6.0 m, have been investigated experimentally, and then scaled up, to 9.0 and 12.0 m, by numerical simulation using ANSYS-FLUENT®15 software. Results demonstrated that collector diameter has effectively influenced the system performance. Larger collector diameter imposed increase in the velocity, temperature and the daily average thermal efficiency of the system. From the experimental results, increasing the collector diameter from 3.0 to 6.0 m has increased the daily average thermal efficiency of the collector from 9.81 to 12.8. Simulation results at 800 W/m2 irradiation revealed that the velocity in the chimney have increased from 1.66 m/s at 3.0 m collector diameter to 2.34, 2.47 and 2.63 m/s for 6.0, 9.0 and 12.0 m collector diameters, respectively.

  17. Thermal performance of a double-pass solar collector with porous media

    International Nuclear Information System (INIS)

    Elradi A Musa; Kamaruzzaman Sopian; Shahrir Abdullah

    2006-01-01

    Thermal performance of a double-pass solar collector has been developed for air following through the porous media. The porous media are arranged in different porosities to increase heat transfer, area density and the total heat transfer rate. A test collector was developed and tested indoors by varying the design features and operating conditions using a halogen-lamp simulator as a radiation source. An experimental setup as been designed and constructed. Comparisons of the theoretical and the experimental result have been conducted. This type of collector can be used for drying and heat applications such as solar industrial processes, space and solar drying of agricultural products

  18. Object-oriented simulation model of a parabolic trough solar collector: Static and dynamic validation

    Science.gov (United States)

    Ubieta, Eduardo; Hoyo, Itzal del; Valenzuela, Loreto; Lopez-Martín, Rafael; Peña, Víctor de la; López, Susana

    2017-06-01

    A simulation model of a parabolic-trough solar collector developed in Modelica® language is calibrated and validated. The calibration is performed in order to approximate the behavior of the solar collector model to a real one due to the uncertainty in some of the system parameters, i.e. measured data is used during the calibration process. Afterwards, the validation of this calibrated model is done. During the validation, the results obtained from the model are compared to the ones obtained during real operation in a collector from the Plataforma Solar de Almeria (PSA).

  19. Recent Optical and SEM Characterization of Genesis Solar Wind Concentrator Diamond on Silicon Collector

    Science.gov (United States)

    Allton, Judith H.; Rodriquez, M. C.; Burkett, P. J.; Ross, D. K.; Gonzalez, C. P.; McNamara, K. M.

    2013-01-01

    One of the 4 Genesis solar wind concentrator collectors was a silicon substrate coated with diamond-like carbon (DLC) in which to capture solar wind. This material was designed for analysis of solar nitrogen and noble gases [1, 2]. This particular collector fractured during landing, but about 80% of the surface was recovered, including a large piece which was subdivided in 2012 [3, 4, 5]. The optical and SEM imaging and analysis described below supports the subdivision and allocation of the diamond-on-silicon (DOS) concentrator collector.

  20. Thermal performance evaluation of the Suncatcher SH-11 (liquid) solar collector

    Science.gov (United States)

    1980-01-01

    The procedures used and the results obtained during the evaluation test program on the Solar Unlimited, Inc., Suncatcher SH-11 (liquid) solar collector are presented. The flat-plate collector case assembly is made of .08 inch aluminum 3003 H14 riveted with fiberglass board insulation. The absorber consists of collared aluminum fins mechanically bonded to 3/8 inch copper tubing and coated with 3M Nextel black. Water is used as the working fluid. The glazing is made of a single glass, 1/8 inch water white, tempered and antireflective. The collector weight is 85 pounds with overall external dimensions of about 35.4 in x 82.0 in x 4.0 in. Thermal performance data on the Solar Unlimited Suncatcher SH-11 solar collector under simulated conditions were conducted using the MSFC Solar Simulator.

  1. Effect of Glass Thickness on Performance of Flat Plate Solar Collectors for Fruits Drying

    Directory of Open Access Journals (Sweden)

    Ramadhani Bakari

    2014-01-01

    Full Text Available This study aimed at investigating the effect of thickness of glazing material on the performance of flat plate solar collectors. Performance of solar collector is affected by glaze transmittance, absorptance, and reflectance which results into major heat losses in the system. Four solar collector models with different glass thicknesses were designed, constructed, and experimentally tested for their performances. Collectors were both oriented to northsouth direction and tilted to an angle of 10° with the ground toward north direction. The area of each collector model was 0.72 m2 with a depth of 0.15 m. Low iron (extra clear glass of thicknesses 3 mm, 4 mm, 5 mm, and 6 mm was used as glazing materials. As a control, all collector performances were analysed and compared using a glass of 5 mm thickness and then with glass of different thickness. The results showed that change in glass thickness results into variation in collector efficiency. Collector with 4 mm glass thick gave the best efficiency of 35.4% compared to 27.8% for 6 mm glass thick. However, the use of glass of 4 mm thick needs precautions in handling and during placement to the collector to avoid extra costs due to breakage.

  2. Evaluation of a tracking flat-plate solar collector in Brazil

    International Nuclear Information System (INIS)

    Maia, Cristiana B.; Ferreira, André G.; Hanriot, Sérgio M.

    2014-01-01

    The continuing research for an alternative power source due to the perceived scarcity of fuel fossils has, in recent years, given solar energy a remarkable edge. Nevertheless, the Earth's daily and seasonal movement affects the intensity of the incident solar radiation. Devices can track the sun in order to ensure optimum positions with regard to incident solar radiation, maximizing the absorbed solar energy, and the useful energy gain. In this paper, a mathematical model is developed to estimate the solar radiation absorbed, the useful energy gain, and the efficiency of a flat-plate solar collector in Brazil. The results for a sun tracking flat-plate solar collector were compared to fixed devices. The full tracking system with rotation about two axes presented higher absorbed energy, when compared to the rotation about a single axe and to a fixed collector. Also, it was shown that the tilt angle for a fixed solar collector does not cause significant variations in the useful energy gain or in the absorbed solar radiation, for the same azimuth angle. - Highlights: • A model was developed for solar radiation based on experimental data for K T . • Useful energy gain and efficiency of a flat-plate solar collector were evaluated for a one-year period. • Several sun tracking systems were compared to fixed devices. • Tilt angle for a fixed device does not significantly affect the useful energy gain

  3. Theoretical and experimental investigation of plate screen mesh heat pipe solar collector

    International Nuclear Information System (INIS)

    Brahim, Taoufik; Dhaou, Mohammed Houcine; Jemni, Abdelmajid

    2014-01-01

    Highlights: • Experimental and computer simulation are performed for wicked heat pipe solar collectors. • Outdoor tests are conducted to compare its performance at different period of the year. • Modest improvement of the collector is achievement by adding fins to the condenser region. • Mesh number of heat pipe porous structure is an important factor in collector design. • Water slightly outperform methanol for such design and operating conditions. - Abstract: Heat pipes are efficient heat transfer devices for solar hot water heating systems. However, the effective downward transfer of solar energy in an integrated heat pipe system provides increased design and implementation options. There is a lack of literature about flat plate wicked assisted heat pipe solar collector, especially with the presence of finned water-cooled condenser wicked heat pipes for solar energy applications. In this paper the consequence of incorporating fins arrays into the condenser region of screen mesh heat pipe solar collector is investigated. An experimental and a transient theoretical model are conducted to compare the performances of solar heating system at different period of the year. A good agreement is shown between the model and the experiment. Two working fluids are investigated (water and methanol) and results reveal that water slightly outperforms methanol with a collector instantaneous efficiency of nearly 60%. That modest improvement is achieved by adding fins to the condenser region of the heat pipes. Results show that the collector efficiency increase as the number of fins increases (upon certain number) and reveal that the mesh number is an important factor which affect the overall collector efficiency. An optimal heat pipe mesh number of 100 meshes/in. with two layers appears to be favorable in such collectors for their design and operating conditions

  4. Solar thermal collectors in polymeric materials: A novel approach towards higher operating temperatures

    Energy Technology Data Exchange (ETDEWEB)

    Mendes, Joao Farinha; Horta, Pedro; Carvalho, Maria Joao [INETI - Inst. Nacional de Engenharia Tecnologia e Inovacao, IP, Lisboa (Portugal); Silva, Paulo [PLASDAN - Maquinas para Plasticos, Marinha Grande (Portugal)

    2008-07-01

    The increasing demand for low temperature solar thermal collectors, especially for hot water production purposes in dwellings, swimming pools, hotels or industry, has lead to the possibility of high scale production, with leading manufacturers presenting yearly productions of hundreds of thousands of square meters. In such conditions, the use of polymeric materials in the manufacturing of solar collectors acquires particular interest, opening a full scope of opportunities for lower production costs, by means of cheaper materials or simpler manufacturing operations. Yet, the use of low cost materials limits the maximum operating temperatures estimated for the collectors (stagnation) to values around 120 C, easily attainable by any simple glazed solar collector. Higher performances, leading to higher stagnation temperatures as those observed for regular metal-based solar thermal collectors, would require high temperature polymers, at a much higher cost. The present paper addresses the manufacturing of a high performance solar thermal collector based in polymeric materials and includes a base thermal study, highlighting the different possibilities to be followed in the production of a polymeric collector, as well as a description of different temperature control strategies. (orig.)

  5. Performance Evaluation of a Nanofluid-Based Direct Absorption Solar Collector with Parabolic Trough Concentrator

    Directory of Open Access Journals (Sweden)

    Guoying Xu

    2015-12-01

    Full Text Available Application of solar collectors for hot water supply, space heating, and cooling plays a significant role in reducing building energy consumption. For conventional solar collectors, solar radiation is absorbed by spectral selective coating on the collectors’ tube/plate wall. The poor durability of the coating can lead to an increased manufacturing cost and unreliability for a solar collector operated at a higher temperature. Therefore, a novel nanofluid-based direct absorption solar collector (NDASC employing uncoated collector tubes has been proposed, and its operating characteristics for medium-temperature solar collection were theoretically and experimentally studied in this paper. CuO/oil nanofluid was prepared and used as working fluid of the NDASC. The heat-transfer mechanism of the NDASC with parabolic trough concentrator was theoretically evaluated and compared with a conventional indirect absorption solar collector (IASC. The theoretical analysis results suggested that the fluid’s temperature distribution in the NDASC was much more uniform than that in the IASC, and an enhanced collection efficiency could be achieved for the NDASC operated within a preferred working temperature range. To demonstrate the feasibility of the proposed NDASC, experimental performances of an NDASC and an IASC with the same parabolic trough concentrator were furthermore evaluated and comparatively discussed.

  6. Low temperature desalination using solar collectors augmented by thermal energy storage

    International Nuclear Information System (INIS)

    Gude, Veera Gnaneswar; Nirmalakhandan, Nagamany; Deng, Shuguang; Maganti, Anand

    2012-01-01

    Highlights: ► A new low temperature desalination process using solar collectors was investigated. ► A thermal energy storage tank (TES) was included for continuous process operation. ► Solar collector area and TES volumes were optimized by theoretical simulations. ► Economic analysis for the entire process was compared with and without TES tank. ► Energy and emission payback periods for the solar collector system were reported. -- Abstract: A low temperature desalination process capable of producing 100 L/d freshwater was designed to utilize solar energy harvested from flat plate solar collectors. Since solar insolation is intermittent, a thermal energy storage system was incorporated to run the desalination process round the clock. The requirements for solar collector area as well as thermal energy storage volume were estimated based on the variations in solar insolation. Results from this theoretical study confirm that thermal energy storage is a useful component of the system for conserving thermal energy to meet the energy demand when direct solar energy resource is not available. Thermodynamic advantages of the low temperature desalination using thermal energy storage, as well as energy and environmental emissions payback period of the system powered by flat plate solar collectors are presented. It has been determined that a solar collector area of 18 m 2 with a thermal energy storage volume of 3 m 3 is adequate to produce 100 L/d of freshwater round the clock considering fluctuations in the weather conditions. An economic analysis on the desalination system with thermal energy storage is also presented.

  7. Surface Texturing Investigated for a High Solar Absorptance Low Infrared Emittance Solar Collector

    Science.gov (United States)

    Jaworske, Donald A.

    2001-01-01

    The objective of this work was to design, build, and vacuum test a high solar absorptance, low infrared emittance solar collector for heat engine and thermal switching applications. Mini-satellites proposed by the Applied Physics Laboratory for operation in environments that are subject to radiation threat may utilize a heat engine for power and a thermal bus for thermal control. To achieve this goal, a surface having high solar absorptance and low infrared emittance is needed. At the NASA Glenn Research Center, one concept being pursued to achieve this goal is texturing high thermal conductivity graphite epoxy composites using a directed atomic oxygen beam and then coating the textured surface with a reflective metallic coating. Coupons were successfully textured, coated, and evaluated. A variety of texturing conditions were explored, and textures were documented by scanning electron microscopy. Copper, gold, silver, iridium, and aluminum coatings were applied, and the highest solar absorptance to infrared emittance ratio was found to be 1.3. A full-sized solar collector was manufactured with this ratio, and the amount of heat collected was observed using an Inconel calorimeter installed in a bench-top vacuum chamber equipped with a solar simulator. Results to date indicate good heat flow through the system, with 9 W of heat flow measured by the calorimeter.

  8. Comparative performance of twenty-three types of flat plate solar energy collectors

    Science.gov (United States)

    Simon, F. F.

    1975-01-01

    Report compares efficiencies of 23 solar collectors for four different purposes: operating a Rankine-cycle engine, heating or absorption air conditioning, heating hot water, and heating a swimming pool.

  9. Wind Tunnel Tests of Parabolic Trough Solar Collectors: March 2001--August 2003

    Energy Technology Data Exchange (ETDEWEB)

    Hosoya, N.; Peterka, J. A.; Gee, R. C.; Kearney, D.

    2008-05-01

    Conducted extensive wind-tunnel tests on parabolic trough solar collectors to determine practical wind loads applicable to structural design for stress and deformation, and local component design for concentrator reflectors.

  10. Performance of solar collectors under low temperature conditions

    DEFF Research Database (Denmark)

    Bunea, Mircea; Eicher, Sara; Hildbrand, Catherine

    temperature, condensation) is investigated under different operating conditions (day and night). Under some conditions condensation might occur and heat gains could represent up to 55% of the total unglazed collector energy by night. Two TRNSYS collector models including condensation heat gains are also...... to be around 2%, frost heat gains were measured to be up to 40% per day, under specific conditions. Overall, results have shown that unglazed collectors are more efficient than flat plate or evacuated tube collectors at low operation temperatures or for night conditions, making them more suitable for heat pump...

  11. Solar collecting characteristics of regenerative solar air collector; Chikunetsushiki kuki shunetsuki no shunetsu tokusei

    Energy Technology Data Exchange (ETDEWEB)

    Aoki, H.; Takano, S.; Kamitaira, T. [Hachinohe Institute of Technology, Aomori (Japan)

    1997-11-25

    In order to develop a solar drying equipment for agricultural and marine products, a regenerative solar air collector was fabricated on a trial basis, which uses round stones as a heat storing material. Its heat collecting characteristics were discussed. The air heat collector was installed on a roof of the Hachinohe Engineering University facing due south. The inside of the air heat collector is lined with heat insulating material with a thickness of 30 mm, and black-painted round stones were laid as an heat insulating material on the floor and the north face. The collector is of a natural air circulating system in which outside air enters from an entrance open to atmosphere, and warmed air exits from upper exit. A selectively absorbing face plaque for accelerating the natural circulation was suspended on the upper part of the north face of the collector. An experiment was performed also on a case in which air is forcibly circulated by fan from the air exit hole. In the natural circulation system, high heat collecting efficiency is shown in the forenoon. However, heat loss increases as temperature in the equipment rises, and heat stored in the round stones during daytime was dissipated completely in the afternoon to night. In the case of the forced circulation system, heat collecting efficiency as high as about 90% was shown in sunny days. This is thought because of heat storage buffering action due to storage of heat in and its dissipation from the round stones, and because of suppression of heat dissipation from the glass surface. 1 ref., 9 figs.

  12. Mathematical model of heat-mass exchange processes in a flat solar collector SUN 1

    Directory of Open Access Journals (Sweden)

    Tunik Aleksandr Aleksandrovich

    2016-01-01

    Full Text Available In a flat solar collector SUN 1 The active development of environmental friendly energy sources alternative to HPPs is currently of great importance in the world. Such alternative energy sources are: water, ground, sun, wind, biofuel, etc. If we have a look at the atlas of solar energy resources on the territory of Russia, we can make a conclusion, that in many regions of our country solar activity level allows using solar collector. Though the analysis of different models of solar collector showed, that most of them are ineffective in the regions with cold climate, though the solar activity of these regions is of a great level. In this regard, a mathematical model of heat-mass exchange processes in flat solar collectors is introduced in this article. The model was a basis for the development of a new solar collector, named SUN 1, which has an original heating tubes form. This form allows heat transfer medium to be under the influence of solar energy for a longer time and consequently to warm to a higher temperature, increasing the warming rapidity.

  13. Thermo-economic optimization of a hybrid solar district heating plant with flat plate collectors and parabolic trough collectors in series

    DEFF Research Database (Denmark)

    Tian, Zhiyong; Perers, Bengt; Furbo, Simon

    2018-01-01

    Large-scale solar heating plants for district heating networks have gained great success in Europe, particularly in Denmark. A hybrid solar district heating plant with 5960 m2 flat plate collectors and 4039 m2 parabolic trough collectors in series was built in Taars, Denmark in 2015. The solar...... to optimize the hybrid solar district heating systems based on levelized cost of heat. It is found that the lowest net levelized cost of heat of hybrid solar heating plants could reach about 0.36 DKK/kWh. The system levelized cost of heat can be reduced by 5–9% by use of solar collectors in the district...... heating network in this study. The results also show that parabolic trough collectors are economically feasible for district heating networks in Denmark. The generic and multivariable levelized cost of heat method can guide engineers and designers on the design, construction and control of large...

  14. Thermal analysis of a solar collector with a standard approach and software used to study windows

    Energy Technology Data Exchange (ETDEWEB)

    Simko, T.; Harrison, S.J. [Queen' s Univ., Kingston, ON (Canada). Dept. of Mechanical and Materials Engineering

    2007-07-01

    A method of calculating the overall heat loss coefficient of a solar collector was presented. The method was based on a standard approach used to obtain total window U-values. A model of the solar collector was developed with a finite element analysis (FEA) program. Heat loss from the solar collector was represented as the gross collector area; the overall heat loss coefficient; and the difference between the assumed mean absorber plate temperature and ambient temperature. The edge heat loss coefficient was approximated by assuming that there was a 1-D sideways heat flow through the edge area of the collector. Regional heat loss coefficients obtained with the model were then used to calculate the overall heat loss coefficient. Equations used for parallel tube type collectors were applied to the serpentine tube collector. The sightline of the solar collector was defined as being the position along the top cover below absorber plate. The same definitions for the extents of the frame, edge and center-of-glass regions for a window were applied to the collector. Multiple U-values were defined to account for heat flows outward across the top, bottom, and side surfaces of the collector. The absorber plate was simulated as being isothermal. Results were then compared with an experimental study in order to validate the method. The method was also compared with results obtained from a conventional analysis for estimating heat loss coefficients. It was concluded that the new method provided more accurate results than those obtained using the conventional method. 16 refs., 1 tab., 5 figs.

  15. Dynamic Modeling of Natural Convection Solar Energy Collectors ...

    African Journals Online (AJOL)

    Expressions were also obtained for the collector instantaneous energy delivery rate, efficiency, heat removal factor, and combined plates coefficient of performance (formally called plates efficiency). A plot of the collector output parameters against time from Os (at 6.00a/m.) showed that each possessed a maximum, which ...

  16. Analysis of thermal and electrical performance of a hybrid (PV/T) air based solar collector for Iraq

    International Nuclear Information System (INIS)

    Amori, Karima E.; Taqi Al-Najjar, Hussein M.

    2012-01-01

    Highlights: ► An improved model is developed for single pass glazed PV/T collector. ► We examined the influence of different parameters. ► A summer day has better heating with lower overall efficiency compared with a winter day. -- Abstract: The electrical and thermal performance of a typical single pass hybrid photovoltaic/thermal (PV/T) air collector is modeled, simulated and analyzed for two selected case studies in Iraq. An improved mathematical thermo-electrical model is derived in terms of design, operating and climatic parameters of the hybrid solar collector to evaluate its important characteristics: collector flow and heat removal factors, PV maximum power point and its temperature coefficient, and overall power and efficiency. Unlike previous PV/T thermal models, the present model is obtained with some additions and corrections in radiation and convection heat coefficients for the top loss and for the air duct with more applicable sky temperature correlation. The well-known 5-parameter electrical model of PV module is solved using improved boundary conditions and translation equations for better convergence and accuracy. The voltage temperature coefficient of the PV module is included in the boundary conditions for convergence stability. The module parameters are taken to be dependent on solar radiation and PV cell temperature for improved accuracy. A Matlab computer simulation program is developed to solve the thermo-electrical model. The developed model is verified with previously published experimental results and theoretical simulations; it is proved to be most accurate in respect to percentage errors and correlation coefficients. Different parameters of the PV/T collector such as cell and air temperatures, thermal gain, PV current and voltage, and fill factor have been investigated. The results identified the effects of most important operating conditions such as sky, inlet and cell temperatures, air flow rate and incident solar radiation on

  17. Comparative study of solar cooling systems with building-integrated solar collectors for use in sub-tropical regions like Hong Kong

    International Nuclear Information System (INIS)

    Fong, K.F.; Lee, C.K.; Chow, T.T.

    2012-01-01

    Highlights: ► Performance of building-integrated solar collectors analyzed. ► Comparisons made with solar collectors installed on roof. ► Use of building-integrated solar collectors increased the total primary consumption. ► Reduction in the building load could not compensate drop in solar collector output. ► Building-integrated solar collectors only used when roof space insufficient. -- Abstract: The performance of solar cooling systems with building-integrated (BI) solar collectors was simulated and the results compared with those having the solar collectors installed conventionally on the roof based on the weather data in Hong Kong. Two types of solar collectors and the corresponding cooling systems, namely the flat-plate collectors for absorption refrigeration and the PV panels for DC-driven vapour compression refrigeration, were used in the analysis. It was found that in both cases, the adoption of BI solar collectors resulted in a lower solar fraction (SF) and consequently a higher primary energy consumption even though the zone loads were reduced. The reduction in SF was more pronounced in the peak load season when the solar radiation was nearly parallel to the solar collector surfaces during the daytimes, especially for those facing the south direction. Indeed, there were no outputs from the BI flat-plate collectors facing the south direction between May and July. The more severe deterioration in the system performance with the BI flat-plate type collectors made them technically infeasible in terms of the energy-saving potential. It was concluded that the use of BI solar collectors in solar cooling systems should be restricted only to situations where the availability of the roof was limited or insufficient when applied in sub-tropical regions like Hong Kong.

  18. Applying measured reflection from the ground to simulations of thermal perfromance of solar collectors

    DEFF Research Database (Denmark)

    Dragsted, Janne; Furbo, Simon

    2009-01-01

    Solar radiation on tilted and vertical surfaces in the Arctic is, in large parts of the year, strongly influenced by reflection from snow. In connection with planning and optimization of energy efficient buildings and solar energy systems in the Arctic, it is important to have an accurate...... and the azimuth of the surface in question. The paper will present an analysis of simulations of the thermal performance of solar collectors using the standard description of the albedo and using the albedo determined by the measurements. It will be elucidated how important an accurate description...... of the reflection from the ground is for the thermal performance of solar collectors....

  19. Buoyancy effects on thermal behavior of a flat-plate solar collector

    DEFF Research Database (Denmark)

    Fan, Jianhua; Furbo, Simon

    2008-01-01

    Theoretical and experimental investigations of the flow and temperature distribution in a 12.53 m(2) solar collector panel with an absorber consisting of two vertical manifolds interconnected by 16 parallel horizontal fins have been carried out. The investigations are focused on overheating...... and the influence of the buoyancy effects are considered in the investigations. Further experimental investigations of the solar collector panel are carried out. The flow distribution through the absorber is evaluated by means of temperature measurements on the back of the absorber tubes. The measured temperatures....... The CFD calculations elucidate the flow and temperature distribution in the collector panels of different designs. Based on the investigations, recommendations are given in order to avoid overheating or boiling problems in the solar collector panel....

  20. Architectural integration of energy solar collectors made with ceramic materials and suitable for the Mediterranean climate

    Directory of Open Access Journals (Sweden)

    J. Roviras

    2016-12-01

    Full Text Available The work presented here aims to demonstrate the technical, architectural and energy viability of solar thermal collectors made with ceramic materials and the Mediterranean climate suitable for the production of domestic hot water (DHW and for heating systems in buildings. The design of a ceramic shell formed by panels collectors and panels no sensors, which are part of the same building system that is capable of responding to the basic requirements of a building envelope and capture solar energy is proposed. Ceramics considerably reduced the final cost of the sensor system and offers the new system a variety of compositional and chromatic since, with reduced performance compared to a conventional metallic collector, can occupy the entire surface of front and get a high degree of architectural integration. A tool for assessing the new ceramic solar collector has been defined from a multi-criteria perspective: economic, environmental and social. The tool enables the comparison of the ceramic solar collector with solar collectors on the market under different climatic and demand conditions.

  1. Thermal efficiency of low cost solar collectors - CSBC; Eficiencia termica de coletores solares de baixo custo - CSBC

    Energy Technology Data Exchange (ETDEWEB)

    Pereira, Renato C.; Shiota, Robson T.; Mello, Samuel F.; Assis Junior, Valdir; Bartoli, Julio R. [Universidade Estadual de Campinas (UNICAMP), SP (Brazil). Faculdade de Engenharia Quimica. Dept. de Tecnologia de Polimeros

    2006-07-01

    The thermal performance of a low cost flat panel solar collector was measured. This Low Cost Solar Collector is a novel concept for water heating using only thermoplastics materials, used on building: ceiling and tubes made of unplasticized PVC, but without transparent cover. The top side of the UPVC panel was black painted to be the solar radiation absorber surface. Prototypes were installed on two charity houses around Campinas and at the FEQ campus, being used without any trouble for one year. The thermal efficiency analysis followed ABNT NBR 10184 standard at the Green-Solar Laboratory, Brazilian Centre for Development of Solar Thermal Energy, PUC-Minas. It was measured a thermal efficiency of 67%, compared to the 75% usually found on conventional solar collectors made of copper tubes and with glass cover. (author)

  2. Study of Performance of Coaxial Vacuum Tube Solar Collector on Ethanol Distillation Process

    Science.gov (United States)

    Sutomo; Ramelan, A. H.; Mustafa; Tristono, T.

    2017-07-01

    Coaxial vacuum tube solar collectors can generate heat up to 80°C is possibly used for ethanol distillation process that required temperature 79°C only. This study reviews the performance of coaxial collector vacuum tube used for ethanol distillation process. This experimental research was conducted in a closed space using a halogen lamp as a solar radiation simulator. We had done on three different of the radiation values, i.e. 998 W/m2, 878 W/m2 and 782 W/m2. The pressure levels of vacuum tube collector cavity in the research were 1; 0.5; 0.31; 0.179; and 0.043 atmospheres. The Research upgraded the 30% of ethanol to produce the concentration of 77% after distillation. The result shows that the performance of coaxial collector vacuum tube used for ethanol distillation process has the negative correlation to the level of the collector tube cavity pressure. The productivity will increase while the collector tube cavity pressure decreased. Therefore, the collector efficiency has the negative correlation also to the level of collector tube cavity pressure. The best performance achieved when it operated at a pressure of 0.043 atmosphere with radiation intensity 878 W / m2, and the value of efficiency is 57.8%.

  3. Plastic solar collector: feature and applications; Colector solar de plastico: Caracteristicas y aplicaciones

    Energy Technology Data Exchange (ETDEWEB)

    Bistoni, Silvia; Iriarte, Adolfo [Universidad Nacional de Catamarca, Catamarca (Argentina); Saravia, Luis [Universidad Nacional de Salta, Salta (Argentina)

    2000-07-01

    The Argentinean northwest (NOA) is an exceptional zone to use solar energy, because of its climate and its solar radiation levels. The aim of this paper is to analyze the use of low temperature solar heating system by mean of a plastic collector. The system proposed includes: a) Solar collectors built with plastic bags, welded in such a way that water, introduced at the top, falls by gravity through a zigzag long path. Each collector is fed by drip feed irrigations. b) Hot water storage and c) Water pump, hydraulic circuit and electronic controls. Two ways of use are proposed: as a water solar heating and as a system to heat greenhouses. In this second case, if during the day the air temperature inside the greenhouse is higher than the water storage temperature, the water will be heated in the bags. During the night the bags work as heat exchanger. When the temperature inside the greenhouse needs to be maintained at a constant value, the heating system is combined with a gas water heating. The equipment is described, performances are compared for both uses and the global heat exchange coefficient is calculated. The system's behavior inside a greenhouse is analyzed in two different situations. The utilization of plastic solar collectors has demonstrate to be a valid alternative for low temperature solar energy uses, specially in heating agricultural spaces. [Spanish] La region del Noreste Argentino (NOA), por su clima y muy en particular por los niveles de radiacion solar que posee, es una zona excepcional para el aprovechamiento de la energia solar. El objetivo de este trabajo es analizar el uso de la energia solar a baja temperatura mediante un colector de plastico. El sistema propuesto incluye: a) Colector solar construido con una bolsa de plastico soldada en forma tal, que el agua que se introduce por la parte superior cae por la gravedad siguiendo un camino en zigzag. Cada colector se alimenta mediante goteros de riego autocompensados. b) Almacenamiento

  4. Comparison of flat plate and cylindrical parabolic focusing solar energy collectors for Oak Ridge

    Energy Technology Data Exchange (ETDEWEB)

    Kronenberger, E.J.; Newman, J.S.; Demetriou, C.V.; Orlandi, R.D.

    1974-05-22

    Experimental and theoretical comparisons were made of the performance of cylindrical parabolic and flat plate solar energy collectors operating under Oak Ridge weather conditions. The flat plate collector was observed to consistently out-perform the parabolic collector under the design and operating (135 to 185/sup 0/F) conditions used (parabolic cylindrical collector - one glass cover plate, refocused hourly, receiver absorptivity of 0.87; flat plate collector - two glass cover plates oriented at latitude minus declination, absorptivity 0.98). Other factors contributed to the difference including poorer insulation (1.25 in. fiberglass) for the focusing collector (versus 5 in. fiberglass for the flat plate) and a poor fin efficiency for the receiver tube of the focusing collector. Observed efficiencies were as high as 47% for the cylindrical parabolic collector operating with one glass plate at 185/sup 0/F and as high as 62% for the flat plate collector operating with two glass plates at 165/sup 0/F. Performance models were developed for both collectors and the model used for the flat plate collector was extended to predict month-to-month operation under Oak Ridge weather conditions (based on the average of 16 years of weather data). A temperature distribution model was developed for optimization of the finned tube receiver used in the cylinderical parabolic collector. Further experimentation should be conducted at higher temperatures (approx. 250/sup 0/F) with selective receiver coatings (..cap alpha../epsilon >> 1) and also runs under conditions of broken cloud cover are suggested. In addition, the performance models should be extended and the finned tube design optimization continued.

  5. Modified mathematical model for evaluating the performance of water-in-glass evacuated tube solar collector considering tube shading effect

    International Nuclear Information System (INIS)

    Kabeel, A.E.; Khalil, A.; Elsayed, S.S.; Alatyar, A.M.

    2015-01-01

    The aim of this paper is to introduce a procedure for simulating the absorbed solar radiation and heat transfer process in water-in-glass evacuated tube solar collectors. The procedure is developed to calculate the daily utilized solar energy and outlet collector temperature for different tilt angles, collector azimuth angles and geometric parameters without requirement for any experimental factor determination. Total absorbed solar radiation is evaluated by integrating the flat-plate solar collector performance equations over the tube circumference taking into account the shading of the adjacent tubes and variance of transmissivity–absorptivity product with the incidence angle of radiation. The heat transfer into the collector fluid is evaluated by subtracting the heat loss from the total absorbed solar radiation. Comparison between calculated and measured tank temperature shows a good agreement between them under different heating loads. Performance of solar collector at different tilt angles, collector Azimuth angles, tubes spacing and collector mass flow rate is investigated theoretically. In Egypt (30° Latitude angle), the results show that 10°, 30° and 45° are the optimum solar collector tilt angles during the summer, vernal and autumnal equinox and winter operation respectively. Also, the utilized solar energy increases about 2.8% when the mass flow rate increases 100%, and the solar collector with south-facing has the best performance except for vertical tube solar collector. The simulation results also show that solar collector with wide tube spacing reduce the shading effect and hence increase the absorbed radiation. The final tank temperature as a function of collector's mass flow rate for three different days; 21 March, 21 June and 21 December is also investigated. The total incidence radiation, absorbed solar radiation and utilized heat per tube are presented for the three optimum tilt angles 10°, 30° and 45°. Efficiency curve of water

  6. Parametric sensitivity studies on the performance of a flat plate solar collector in transient behavior

    International Nuclear Information System (INIS)

    Hamed, Mouna; Fellah, Ali; Ben Brahim, Ammar

    2014-01-01

    Highlights: • Parametric studies of a flat plate solar collector is developed. • The model predicts the temperature profile of all the components of the collector and of the working fluid. • A simulation program was constructed to study the effect parameters. • The optimal performance and design of solar collector system was carried out. - Abstract: In this paper, a numerical investigation of flat plate solar collectors is developed to determine the optimal performance and design parameters of these solar to thermal energy conversion systems. The collector is used to supply hot water. It consists of three main components, namely a transparent cover, an absorber and a transfer fluid. A transient simulation method has been developed to characterize the dynamic behavior. The model was established regarding the energy balance analysis. A set of equations representing the model was simultaneously solved. The results are used to investigate the effect of various parameters on the performance of the collector such as outlet water temperature and overall heat loss coefficient. The overall methodology has been developed on environmental data which are characteristic of the city of Gabes in Tunisia

  7. Improvement of solar air collectors: Study and Experimental Research Project. Final report, May 1976-June 1978

    Energy Technology Data Exchange (ETDEWEB)

    Cole-Appel, B.E.; Loef, G.O.G.; Shaw, L.E.; Fischer, B.B.

    1978-01-01

    Literature and patents relevant to solar air-heating collectors were reviewed. The design constraints are listed. The analysis considered the heat transfer and pressure loss characteristics of the various designs. Three absorbers along with the baseline design were mounted in identical collector bodies and subjected to thermal efficiency tests on Solaron's collector test stand. The testing was done simultaneously on the four panels in a side-by-side collector test. Various manufacturing techniques for producing an absorber with extended heat transfer surface were investigated. It was found that fins could be attached to the absorber in a cost-effective manner by an electrical resistance weld. Four finned absorbers were fabricated by resistance welding and installed in a 2 x 2 collector array to verify that these production model prototypes would, in fact, increase performance by a factor of 1.11. (MHR)

  8. Results of IEA SHC Task 45: Large Scale Solar Heating and Cooling Systems. Subtask A: “Collectors and Collector Loop”

    DEFF Research Database (Denmark)

    Bava, Federico; Nielsen, Jan Erik; Knabl, Samuel

    2016-01-01

    . Within this project, subtask A had the more specific objectives of investigating ways to evaluate the influence that different operating conditions can have on the collector performance, assure proper and safe installation of large solar collector fields, and guarantee their performance and yearly energy......The IEA SHC Task 45 Large Scale Solar Heating and Cooling Systems, carried out between January 2011 and December 2014, had the main objective to assist in the development of a strong and sustainable market of large solar heating systems by focusing on high performance and reliability of systems...... output. The results of the different investigations are presented, with a particular focus on how different parameters such as tilt, flow rate and fluid type, can affect the collector efficiency. Other presented results include methods to guarantee and check the thermal performance of a solar collector...

  9. Double-pass photovoltaic / thermal (PV/T) solar collector with advanced heat transfer features

    International Nuclear Information System (INIS)

    Mohd Nazari Abu Bakar; Baharudin Yatim; Mohd Yusof Othman; Kamaruzzaman Sopian

    2006-01-01

    The use of PV/T in combination with concentrating reflectors has a potential to significantly increase power production from a given solar cell area. A prototype double-pass photovoltaic-thermal solar air collector with CPR and fins has been designed and fabricated and its performance over a range of operating conditions was studied. The absorber of the hybrid photovoltaic / thermal (PV/T) collector under investigation consists of an array of solar cells for generating electricity, compound parabolic concentrator (CPR) to increase the radiation intensity falling on the solar cells and fins attached to the back side of the absorber plate to improve heat transfer to the flowing air. The thermal, electrical and combined electrical and thermal efficiencies of the collector are presented and discussed

  10. Performance of a Solar Heating System with Photovoltaic Thermal Hybrid Collectors and Heat Pump

    DEFF Research Database (Denmark)

    Dannemand, Mark; Furbo, Simon; Perers, Bengt

    2017-01-01

    The energy consumption in buildings accounts for a large part of the World’s CO2 emissions. Much energy is used for appliances, domestic hot water preparation and space heating. In solar heating systems, heat is captured by solar collectors when the sun is shining and used for heating purposes....... When the solar collectors are unable to supply the heat demand an auxiliary heat source is used. Heat pumps can generate this heat. Liquid/water heat pumps have better performance than air/water heat pumps in cold climates but requires installation of a tubing system for the cold side of the heat pump....... The tubes are typically placed in the ground, requires a significant land area and increase the installation cost. A new system design of a solar heating system with two storage tanks and a liquid/water heat pump is presented. The system consists of PVT collectors that generate both heat and electricity...

  11. MULTIFUNCTIONAL ALTERNATIVE ENERGY SYSTEMS ON THE BASIS OF GAS-LIQUID SOLAR COLLECTORS

    Directory of Open Access Journals (Sweden)

    Doroshenko A.V.

    2012-12-01

    Full Text Available The basic circuits of multifunctional solar systems of drainage of air, heating (hot water supply and heating, cooling and air conditioning are developed on the basis of open absorption cycle with direct absorbent regeneration. The basic solutions for new generation of gas-liquid solar collectors are developed.

  12. Design and Development of Prototype Cylindrical Parabolic Solar Collector for Water Heating Application

    Directory of Open Access Journals (Sweden)

    Hrushikesh Bhujangrao Kulkarni

    2016-02-01

    Full Text Available Concentrating collectors absorbs solar energy and convert it into heat for generating hot water, steam at required temperature, which can be further used for solar thermal applications. The developing countries like India where solar energy is abundantly available; there is need to develop technology for harnessing solar energy for power production, but the main problem associated with concentrating solar power technology is the high cost of installation and low output efficiency. To solve this problem, a prototype cylindrical parabolic solar collector having aperture area of 1.89 m2 is designed and developed using low cost highly reflecting and absorbing material to reduce initial cost of project and improve thermal efficiency. ASHRAE Standard 93, 1986 was used to evaluate the thermal performance and it was observed that this system can generate hot water at an average temperature of 500C per day with an average efficiency of 49% which is considerable higher than flat plate solar collectors. Hot water produced by this system can be useful for domestic, agricultural, industrial process heat applications.Article History: Received Sept 19, 2015; Received in revised form Dec 23, 2015; Accepted February 2, 2016; Available online How to Cite This Article: Bhujangrao, K.H. (2016. Design and Development of Prototype Cylindrical Parabolic Solar Collector for Water Heating Application. International Journal of Renewable Energy Development, 5(1, 49-55 http://dx.doi.org/10.14710/ijred.5.1.49-55 

  13. Performance of nanofluids on heat transfer in a wavy solar collector ...

    African Journals Online (AJOL)

    The problem of steady, laminar and incompressible natural convection flow in a wavy solar collector is studied. In this investigation, two vertical walls are perfectly insulated. The top cover glass surface is continuously absorbing solar energy. The bottom wavy solid surface is kept at a constant temperature Tc. Numerical ...

  14. Development of Proposed Standards for Testing Solar Collectors and Thermal Storage Devices. NBS Technical Note 899.

    Science.gov (United States)

    Hill, James E.; And Others

    A study has been made at the National Bureau of Standards of the different techniques that are or could be used for testing solar collectors and thermal storage devices that are used in solar heating and cooling systems. This report reviews the various testing methods and outlines a recommended test procedure, including apparatus and…

  15. Preliminary experimental study of post-combustion carbon capture integrated with solar thermal collectors

    International Nuclear Information System (INIS)

    Wang, Fu; Zhao, Jun; Li, Hailong; Deng, Shuai; Yan, Jinyue

    2017-01-01

    Highlights: • A solar assisted chemical absorption pilot system with two types of collectors (parabolic trough and linear Fresnel reflector) has been constructed. • Performance of two types of solar collectors has been investigated and compared at steady and transient states. • The operations of the pilot system with and without solar assisted have been tested. • The pilot system responds to the temperature of the heat transfer fluid regularly. - Abstract: The amine-based chemical absorption for CO 2 capture normally needs to extract steam from the steam turbine cycle for solvent regeneration. Integrating solar thermal energy enables the reduction of steam extraction and therefore, can reduce the energy penalty caused by CO 2 capture. In this paper, a pilot system of the solar thermal energy assisted chemical absorption was built to investigate the system performance. Two types of solar thermal energy collectors, parabolic trough and linear Fresnel reflector, were tested. It was found that the values of operation parameters can meet the requirements of designed setting parameters, and the solar collectors can provide the thermal energy required by the reboiler, while its contribution was mainly determined by solar irradiation. The solvent regeneration was investigated by varying the heat input. The results show that the response time of the reboiler heat duty is longer than those of the reboiler temperature and desorber pressure. This work provides a better understanding about the overall operation and control of the system.

  16. Predicting the performance of amorphous and crystalline silicon based photovoltaic solar thermal collectors

    International Nuclear Information System (INIS)

    Daghigh, Ronak; Ibrahim, Adnan; Jin, Goh Li; Ruslan, Mohd Hafidz; Sopian, Kamaruzzaman

    2011-01-01

    BIPVT is an application where solar PV/T modules are integrated into the building structure. System design parameters such as thermal conductivity and fin efficiency, type of cells, type of coolant and operating conditions are factors which influence the performance of BIPVT. Attempts have been made to improve the efficiency of building-integrated photovoltaic thermal (BIPVT). A new design concept of water-based PVT collector for building-integrated applications has been designed and evaluated. The results of simulation study of amorphous silicon (a-Si) PV/T and crystalline silicon (c-Si) module types are based on the metrological condition of Malaysia for a typical day in March. At a flow rate of 0.02 kg/s, solar radiation level between 700 and 900 W/m 2 and ambient temperature between 22 and 32 o C, the electrical, thermal and combined photovoltaic thermal efficiencies for the PV/T (a-Si) were 4.9%, 72% and 77%, respectively. Moreover, the electrical, thermal and combined photovoltaic thermal efficiencies of the PV/T (c-Si) were 11.6%, 51% and 63%.

  17. The EIR-programmes for computing the gross heat output of solar collectors (MURD and ETA)

    International Nuclear Information System (INIS)

    Widder, F.

    1980-11-01

    For the computation of the gross heat output of solar collectors by means of meteo data and characteristic collector parameters two programs were developed: MURD for the determination of the ''mean usable radiation density'' and ETA for the calculation of the collector efficiency i.e. relative values of gross heat output. The main features of these programs are described and detailed instructions for the use of them are given. Results of some cases for the meteo-situation of Zurich airport are given. (Auth.)

  18. Sensitive Analysis for the Efficiency of a Parabolic Trough Solar Collector Based on Orthogonal Experiment

    OpenAIRE

    Xiaoyan Liu; Jing Huang; Qianjun Mao

    2015-01-01

    A multitude of the researches focus on the factors of the thermal efficiency of a parabolic trough solar collector, that is, the optical-thermal efficiency. However, it is limited to a single or double factors for available system. The aim of this paper is to investigate the multifactors effect on the system’s efficiency in cold climate region. Taking climatic performance into account, an average outlet temperature of LS-2 collector has been simulated successfully by coupling SolTrace softwar...

  19. Annual Optimum Tilt Angle Prediction of Solar Collector using PSO Estimator

    Science.gov (United States)

    Dixit, T. V.; Yadav, Anamika; pre="Senior Member ">IEEE,

    2017-08-01

    The amount of solar flux falls on solar collector depends on tilt angle and orientation of collector from the surface. By efficiently regulating the tilt and orientation of solar collector unnecessary loss in potential power can be minimized. In general, for north hemisphere, south facing of the collector is considered as optimum orientation. There are several metrological and geographical factors which affect the optimum tilt angle. In this paper, the PSO estimator has been proposed in order to find optimum tilt angle on annual basis. The results of PSO estimators are compared with ANN estimator and satellite (RETScreen software) data. To evaluate the performance of proposed model MBE, RMSE, Error range, percentage annual error as well as direct method of statistical study have been carried out. During annual tilt angle prediction the annual percentage errors of proposed method and RETScreensoftware data are 0.03% and 7.03% respectively with respect to ANN results. Finally, the average percentage error indicates that the proposed estimator gives better prediction as compared to satellite based results for collecting maximum solar flux at surface of solar collector.

  20. Thermodynamic model to study a solar collector for its application to Stirling engines

    International Nuclear Information System (INIS)

    Abdollahpour, Amir; Ahmadi, Mohammad H.; Mohammadi, Amir H.

    2014-01-01

    Highlights: • A thermodynamic model is presented to study a solar collector for its application to Stirling engines. • The parabolic collector is analyzed based on optical and thermal. • Effects of changing some conditions and parameters are studied. - Abstract: Energy production through clean and green sources has been paid attention over the last decades owing to high energy consumption and environmental emission. Solar energy is one of the most useful energy sources. Due to high investment cost of centralized generation of electricity and considerable loss in the network, it is necessary to look forward to decentralized electricity generation technologies. Stirling engines have high efficiency and are able to be coupled with solar energy which cannot be applied in internal combustion engines. Solar Stirling engines can be commercialized and used to generate decentralized electricity in small to medium levels. One of the most important steps to set up an efficient solar Stirling engine is choosing and designing the collector. In this study, a solar parabolic collector with 3500 W of power for its application to Stirling engines was designed and analyzed (It is the thermal inlet power for a Stirling engine). We studied the parabolic collector based on optical and thermal analysis. In this case, solar energy is focused by a concentrating mirror and transferred to a pipe containing fluid. MATLAB software was used for obtaining the parameters of the collector, with respect to the geographic, temporal, and environmental conditions, fluid inlet temperature and some other considerations. After obtaining the results of the design, we studied the effects of changing some conditions and parameters such as annular space pressure, type of the gas, wind velocity, environment temperature and absorber pipe coating

  1. Effect of solar irradiation on forced convective heat transfer through a nanofluid based direct absorption solar collector

    Science.gov (United States)

    Parvin, Salma; Ahmed, Sajid; Chowdhury, Raju

    2017-06-01

    The present work investigates numerically the convective and radiative heat transfer performance and entropy generation of forced convection through a direct absorption solar collector (DASC). Four different fluids; Cu-water nanofluid, Al2O3-waternanofluid, TiO2-water nanofluid and pure water are used as the working fluid. Entropy production has been taken into account in addition to the collector efficiency and heat transfer enhancement. Penalty finite element method with Galerkin's weighted residual technique is used to solve the governing non-linear partial differential equations. Numerical simulations are performed for the variation of solar irradiation (I). The outcomes are presented in the form of isotherms, average output temperature, the average Nusselt number, collector efficiency, average entropy generation and Bejan number. The results present that the rate of heat transfer and collector efficiency enhance significantly for raising the values of I upto a certain range.

  2. Solar tests of aperture plate materials for solar thermal dish collectors

    Science.gov (United States)

    Jaffe, L. D.

    1983-08-01

    In parabolic dish solar collectors, walk-off of the spot of concentrated sunlight is a hazard if a malfunction causes the concentrator to stop following the Sun. Therefore, a test program was carried out to evaluate the behavior of various ceramics, metals, and polymers under solar irradiation of about 7000 kW/sq m. (peak) for 15 minutes. The only materials that did not slump or shatter were two grades of medium-grain extruded graphite. High purity, slip-cast silica might be satisfactory at somewhat lower flux. Oxidation of the graphite appeared acceptable during tests simulating walk-off, acquisition (2000 cycles on/off Sun), and spillage (continuous on-Sun operation).

  3. Compendium of information on identification and testing of materials for plastic solar thermal collectors

    Energy Technology Data Exchange (ETDEWEB)

    McGinniss, V.D.; Sliemers, F.A.; Landstrom, D.K.; Talbert, S.G.

    1980-07-31

    This report is intended to organize and summarize prior and current literature concerning the weathering, aging, durability, degradation, and testing methodologies as applied to materials for plastic solar thermal collectors. Topics covered include (1) rate of aging of polymeric materials; (2) environmental factors affecting performance; (3) evaluation and prediction of service life; (4) measurement of physical and chemical properties; (5) discussion of evaluation techniques and specific instrumentation; (6) degradation reactions and mechanisms; (7) weathering of specific polymeric materials; and (8) exposure testing methodology. Major emphasis has been placed on defining the current state of the art in plastics degradation and on identifying information that can be utilized in applying appropriate and effective aging tests for use in projecting service life of plastic solar thermal collectors. This information will also be of value where polymeric components are utilized in the construction of conventional solar collectors or any application where plastic degradation and weathering are prime factors in material selection.

  4. Towards standardization of in-site parabolic trough collector testing in solar thermal power plants

    Science.gov (United States)

    Sallaberry, Fabienne; Valenzuela, Loreto; de Jalón, Alberto García; Leon, Javier; Bernad, Ignacio David

    2016-05-01

    This paper presents a summary of the testing procedure and a validation of the methodology of parabolic trough collector in solar thermal power plants. The applied testing methodology is the one proposed within the Spanish standardization sub-committee AEN/CTN 206/SC117 working group WG2 related to the components for solar thermal power plants. This methodology is also proposed within the international committee IEC TC 117 (Standard draft IEC 62862-3-2 Ed. 1.0). This study is done at Plataforma Solar de Almería (PSA) in Almeria within the European project STAGE-STE. This paper presents the results of the optical and thermal efficiency of a large-size parabolic trough collector. The obtained values are similar to the previous analysis on this collector by PSA. The results of the tracking system have a good accuracy compared to the acceptance angle of the concentrator.

  5. Flat plate solar collector for water pre-heating using concentrated solar power (CSP)

    Science.gov (United States)

    Peris, Leonard Sunny; Shekh, Md. Al Amin; Sarker, Imran

    2017-12-01

    Numerous attempt and experimental conduction on different methods to harness energy from renewable sources are being conducted. This study is a contribution to the purpose of harnessing solar energy as a renewable source by using flat plate solar collector medium to preheat water. Basic theory of solar radiation and heat convection in water (working fluid) has been combined with heat conduction process by using copper tubes and aluminum absorber plate in a closed conduit, covered with a glazed through glass medium. By this experimental conduction, a temperature elevation of 35°C in 10 minutes duration which is of 61.58% efficiency range (maximum) has been achieved. The obtained data and experimental findings are validated with the theoretical formulation and an experimental demonstration model. A cost effective and simple form of heat energy extraction method for space heating/power generation has been thoroughly discussed with possible industrial implementation possibilities. Under-developed and developing countries can take this work as an illustration for renewable energy utilization for sustainable energy prospect. Also a full structure based data to derive concentrated solar energy in any geographical location of Bangladesh has been outlined in this study. These research findings can contribute to a large extent for setting up any solar based power plant in Bangladesh irrespective of its installation type.

  6. Development of 400 F sealants for flat plate solar collector construction and installation

    Science.gov (United States)

    Morris, L.; Schubert, R. J.

    1980-03-01

    Twenty candidate sealants representing ten different polymer types were evaluated as potential solar collector sealants. Polymer types tested included epichlorohydrin rubber, EPDM rubber, silicone, polysulfide, acrylate rubber, and a fluoroelastomer. Initial screening of sealants consisted of measuring high temperature stability and adhesion retention. Several sealant compositions exhibited satisfactory performance in these tests and were selected for further evaluation. These materials were based on an EPDM rubber, a Viton fluoroelastomer, and silicone polymers. Further testing of these candidate materials included determination of adhesion retention under uv/water/heat conditions, fogging temperature, low temperature flexibility, and physical properties. Four silicone-based materials appeared to be suitable candidates for sealing solar collectors.

  7. Metal glass vacuum tube solar collectors are approaching lower-medium temperature heat application.

    Science.gov (United States)

    Jiang, Xinian

    2010-04-26

    Solar thermal collectors are widely used worldwide mainly for hot water preparation at a low temperature (less than 80?C). Applications including many industrial processes and central air conditioning with absorption chillers, instead require lower-medium temperature heat (between 90 degrees C and 150 degrees C) to be driven when using solar thermal energy. The metal absorber glass vacuum tube collectors (MGVT) are developed for this type of applications. Current state-of-art and possible future technology development of MGVT are presented.

  8. Standardized performance tests of collectors of solar thermal energy: A selectively coated, flat-plate copper collector with one transparent cover and a tube-to-tube spacing of 5 5/8 inches

    Science.gov (United States)

    1976-01-01

    This preliminary data report gives basic test results of a flat-plate solar collector whose performance was determined in the NASA-Lewis solar simulator. The collector was tested over ranges of inlet temperatures, fluxes and coolant flow rates. Collector efficiency is correlated in terms of inlet temperature and flux level.

  9. Standard performance tests of collectors of solar thermal energy: A selectively coated, flat-plate copper collector with one transparent cover and a tube-to-tube spacing of 3-7/8 inches

    Science.gov (United States)

    1976-01-01

    Basic test results are given of a flat-plate solar collector whose performance was determined in the NASA-Lewis solar simulator. The collector was tested over ranges of inlet temperatures, fluxes, and coolant flow rates. Collector efficiency is correlated in terms of inlet temperature and flux level.

  10. A comparative numerical study on natural convection in inclined wavy and flat-plate solar collectors

    Energy Technology Data Exchange (ETDEWEB)

    Varol, Yasin [Department of Mechanical Education, Firat University, 23119 Elazig (Turkey); Oztop, Hakan F. [Department of Mechanical Engineering, Firat University, 23119 Elazig (Turkey)

    2008-09-15

    The present study deals with the numerical analysis of natural convection heat transfer inside the inclined solar collectors. Two collectors are compared. In the first case, the collector has wavy absorber and in the second case, it has flat absorber. The solution was performed assuming the isothermal boundary conditions of absorbers and covers of collectors. CFDRC commercial software is used to simulate the laminar flow and thermal field. Governing parameters are taken as Rayleigh number (from 1 x 10{sup 6} to 5 x 10{sup 7}), inclination angle (from 20 to 60 ), wave length (from 1.33 to 4) and aspect ratio (from 0 to 4). Results are presented by streamlines, isotherms and local and mean Nusselt numbers. It is observed that flow and thermal fields are affected by the shape of enclosure and heat transfer rate increases in the case of wavy enclosure than that of flat enclosure. (author)

  11. Optimisation of solar collector foils with transparent thermal insulation. Final report; Optimierung von transparent waermegedaemmten Folien-Speicherkollektoren. Abschlussbericht

    Energy Technology Data Exchange (ETDEWEB)

    Michaelis, M

    1995-02-01

    The report describes storage collector foils which are used as hybrid systems. Contents: State of the art - solar test facility - tests on small test collectors - cost reduction. (HW) [Deutsch] Es wird berichtet ueber Folien-Speicherkollektoren, die als Hybridsysteme zum Einsatz kommen. Inhalt der Arbeit: - Stand der Technik - solare Testanlage - Untersuchungen an kleinen Testkollektoreinheiten - Kostenreduzierung. (HW)

  12. Multiple-effect diffusion solar still coupled with a vacuum-tube collector and heat pipe

    KAUST Repository

    Chong, Tze-Ling

    2014-08-01

    The present study develops a multiple-effect diffusion solar still (MEDS) with a bended-plate design in multiple-effect diffusion unit (MDU) to solve the peel-off problem of wick material. The MDU is coupled with a vacuum-tube solar collector to produce a high temperature gradient for high productivity. A heat pipe is used to transfer the solar heat to the MDU. A prototype MEDS-1L was built and tested outdoors. Four performance indexes are proposed for the performance evaluation of MEDS, including daily pure water production per unit area of glass cover, solar absorber, and evaporating surface (Mcov, Msol, Mevp, respectively), and solar distillation efficiency Rcov. The outdoor test results of MEDS-1L show that the solar collector supply temperature Th reaches 100°C at solar radiation 800Wm-2. The highest Mcov is 23.9kgm-2d-1 which is about 29% higher than the basin-type MEDS [11]. The highest value is 25.9kgm-2d-1 for Msol and 2.79kgm-2d-1 for Mevp. The measured Rcov is 1.5-2.44, higher than the basin-type MEDS (1.45-1.88). The Mcov, Msol, Mevp and Rcov of MEDS-1L are all higher than the theoretical calculation of a MEDS with a flat-plate solar collector coupled with a heat pipe (MEDS-FHP) [17].© 2014 Elsevier B.V.

  13. Usage of hybrid solar collector system in drying technologies of medical plants

    International Nuclear Information System (INIS)

    Čiplienė, Aušra; Novošinskas, Henrikas; Raila, Algirdas; Zvicevičius, Egidijus

    2015-01-01

    Highlights: • Solar radiation energy utilization in drying technologies. • Accumulation of solar radiation energy. • The system comprising two different solar collector types. • Preparation of the drying agent by employing solar radiation energy around the clock. • The energy resources saving technology for medicinal plants’ raw material processing and drying. - Abstract: In the temperate climate zone under natural conditions, medicinal plants drying up to 8–12% moisture content and preparation of the quality medicinal plant’s raw material are complicated tasks. In many cases drying process of medicinal plants raw material, particularly rich in volatile compounds, needs the optimal drying temperatures of 30–45 °C and relative humidity not higher than 50–60%. In Lithuania, located in the northern part of the temperate climate zone, in summer the average temperature of ambient air is 16.1 ± 0.5 °C, and relative humidity is 77.3 ± 1.8%. In order to improve the sorption properties of ambient air, it is heated up to the admissible drying temperature. The experimental dryer was developed comprising two different solar collectors: the air type solar collector with area 12 m 2 for direct heating of the drying agent and the flat-plate type solar collector (8 m 2 ) for accumulation of converted heat energy. The research of motherwort (Leonurus cardiaca L.) drying was carried out in the dryer. It was determined that by combining operation of two different solar collectors, the solar radiation energy for drying agent’s heating could be used continuously around the clock by employing the accumulated energy, in order to compensate the solar irradiance variability and to ensure stability of the drying process. In the daytime the air-type solar collector at an airflow equal to 367 m 3 h −1 , i.e. at comparative flow of the drying agent per ton of dried medicinal plant raw material – 2450 m 3 h −1 , heats the air up to 30 °C when the solar

  14. Performance Analysis of Fractional-Order PID Controller for a Parabolic Distributed Solar Collector

    KAUST Repository

    Elmetennani, Shahrazed

    2017-09-01

    This paper studies the performance of a fractional-order proportional integral derivative (FOPID) controller designed for parabolic distributed solar collectors. The control problem addressed in concentrated solar collectors aims at forcing the produced heat to follow a desired reference despite the unevenly varying solar irradiance. In addition to the unpredictable variations of the energy source, the parabolic solar collectors are subject to inhomogeneous distributed efficiency parameters affecting the heat production. The FOPID controller is well known for its simplicity with better tuning flexibility along with robustness with respect to disturbances. Thus, we propose a control strategy based on FOPID to achieve the control objectives. First, the FOPID controller is designed based on a linear approximate model describing the system dynamics under nominal working conditions. Then, the FOPID gains and differentiation orders are optimally tuned in order to fulfill the robustness design specifications by solving a nonlinear optimization problem. Numerical simulations are carried out to evaluate the performance of the proposed FOPID controller. A comparison to the robust integer order PID is also provided. Robustness tests are performed for the nominal model to show the effectiveness of the FOPID. Furthermore, the proposed FOPID is numerically tested to control the distributed solar collector under real working conditions.

  15. Harmonization of standards for parabolic trough collector testing in solar thermal power plants

    Science.gov (United States)

    Sallaberry, Fabienne; Valenzuela, Loreto; Palacin, Luis G.; Leon, Javier; Fischer, Stephan; Bohren, Andreas

    2017-06-01

    The technology of parabolic trough collectors (PTC) is used widely in concentrating Solar Power (CSP) plants worldwide. However this type of large-size collectors cannot be officially tested by an accredited laboratory and certified by an accredited certification body so far, as there is no standard adapted to its particularity, and the current published standard for solar thermal collectors are not completely applicable to them. Recently some standardization committees have been working on this technology. This paper aims to give a summary of the standardized testing methodology of large-size PTC for CSP plants, giving the physical model chosen for modeling the thermal performance of the collector in the new revision of standard ISO 9806 and the points still to be improved in the standard draft IEC 62862-3-2. In this paper, a summary of the testing validation performed on one parabolic trough collector installed in one of the test facilities at the Plataforma Solar de Almería (PSA) with this new model is also presented.

  16. Transparent solar cell window module

    Energy Technology Data Exchange (ETDEWEB)

    Chau, Joseph Lik Hang; Chen, Ruei-Tang; Hwang, Gan-Lin; Tsai, Ping-Yuan [Nanopowder and Thin Film Technology Center, ITRI South, Industrial Technology Research Institute, Tainan County 709 (China); Lin, Chien-Chu [I-Lai Acrylic Corporation, Tainan City (China)

    2010-03-15

    A transparent solar cell window module based on the integration of traditional silicon solar cells and organic-inorganic nanocomposite material was designed and fabricated. The transparent solar cell window module was composed of a nanocomposite light-guide plate and traditional silicon solar cells. The preparation of the nanocomposite light-guide plate is easy without modification of the traditional casting process, the nanoparticles sol can be added directly to the polymethyl methacrylate (PMMA) monomer syrup during the process. The solar energy collected by this window can be used to power up small household electrical appliances. (author)

  17. On the CFD&HT of the flow around a parabolic trough solar collector under real working conditions

    OpenAIRE

    Amine Hachicha, Ahmed; Rodríguez Pérez, Ivette María; Lehmkuhl Barba, Oriol; Oliva Llena, Asensio

    2013-01-01

    Parabolic trough solar collector is currently one of the most mature and prominent solar applications for production of electricity. These systems are usually located in open terrain where strong winds may occur and affect their stability and optical performance, as well as, the heat exchange between the solar receiver and the ambient air. In this context, a wind flow analysis around a parabolic trough solar collector under real working conditions is performed. A numerical aerodynamic and ...

  18. Theoretical variations of the thermal performance of different solar collectors and solar combi systems as function of the varying yearly weather conditions in Denmark

    DEFF Research Database (Denmark)

    Andersen, Elsa; Furbo, Simon

    2009-01-01

    radiation, but both the annual thermal performance and the annual utilized solar energy can with a reasonable approximation be fitted to a linear function of the yearly solar radiation on the collector for both flat plate and evacuated tubular solar collectors. Also evacuated tubular solar collectors......The thermal performances of solar collectors and solar combi systems with different solar fractions are studied under the influence of the Danish Design Reference Year, DRY data file, and measured weather data from a solar radiation measurement station situated at the Technical University...... of Denmark in Kgs. Lyngby. The data from DRY data file are used for any location in Denmark. The thermal performances of the solar heating systems are calculated by means of validated computer models. The measured yearly solar radiation varies by approximately 23% in the period from 1990 until 2002...

  19. A comparison between the solar energy collection by fix and tracking collectors

    Energy Technology Data Exchange (ETDEWEB)

    Garrison, John D [San Diego State University, San Diego (United States)

    2000-07-01

    A realistic mathematical simulation of solar thermal energy collection for an air flat plate collector, six designs of fixed evacuated collectors and two designs of tracking evacuated collectors at port Hardy, British Columbia and Edmonton, Alberta, in Canada and Daggett, California in the United States has been calculated. Differences in solar energy collection by the different collector designs arise only from differences in collector geometry, since the same collector orientations, selective absorber and solar radiation data are used in the simulations for all collector designs. It is found that solar energy collection in Canada by an air flat plate collector is significantly lower than that of the fixed evacuated and the tracking evacuated collectors at the lowest operating temperatures. This occurs because of the high thermal losses for the air flat plate collector, and the low solar insolation and low winter ambient temperatures in Canada. Highly concentrating tracking collectors which collect no diffuse radiation do not collect as much solar energy at lower temperatures as all of the fixed evacuated collectors at Port Hardy in Canada where there are a limited number of clear days. The fixed, vacuum tubular (dewar type) collector collects the most solar energy at low temperatures. At higher temperatures it collects the least amount of energy of all of the evacuated collectors. This is because of its low concentration and thus larger radiation losses. The vacuum vertical fin and higher concentration shaped glass evacuated collectors at high temperatures. Solar energy collection at Daggett is much higher than that at the two Canadian stations because of the high solar insolation and moderate to warm ambient temperatures. By rotating of the more highly concentrating CPC evacuated collectors about their axes placed parallel to the polar axis so as to track the sun, significantly higher energy collection is obtained, particularly for sites with higher annual

  20. A new Laplace transformation method for dynamic testing of solar collectors

    DEFF Research Database (Denmark)

    Kong, Weiqiang; Perers, Bengt; Fan, Jianhua

    2015-01-01

    A new dynamic method for solar collector testing is developed. It is characterized by using the Laplace transformation technique to solve the differential governing equation. The new method was inspired by the so called New Dynamic Method (NDM) (Amer E. et al (1999) [1]) but totally different....... By integration of the Laplace transformation technique with the Quasi Dynamic Test (QDT) model (Fischer S. et al (2004) [2]), the Laplace – QDT (L-QDT) model is derived. Two experimental methods are then introduced. One is the shielding method which needs to shield and un-shield solar collector continuously...... and the natural experimental method. The identified collector parameters are then compared and analyzed with those obtained by the steady state test method and the QDT test method. The results comparison shows that the L-QDT method and the natural experimental method are also valid. It can be concluded...

  1. PERFORMANCE ANALYSIS OF FORCED CONVECTION EVACUATED TUBE SOLAR COLLECTOR USED FOR GRAPE DRYER

    Directory of Open Access Journals (Sweden)

    A. B. UBALE

    2017-01-01

    Full Text Available In the present experimental study an evacuated tube solar collector is designed, fabricated and its performance is tested in the force convection mode of heat transfer. The solar collector is designed for the grape dryer of capacity 10kg per batch. Experiments are carried out in the month of April to produce raisins for Thomson Seedless grapes, with initial moisture content of 77 (kg per kg on wet basis% to final moisture content of 19 (kg per kg on wet basis% in 36 hours. Raisins produced from this system are tested for varies parameters to check its quality and found satisfactory results. The average collector efficiency is found to be 23.4%.

  2. Effects of nanometric hydrophobic layer on performances of solar photovoltaic collectors

    Directory of Open Access Journals (Sweden)

    Andrei BUTUZA

    2014-11-01

    Full Text Available The study refers to the experimental investigation of solar photovoltaic collectors' behaviour when the glazed surface is treated with a nanometric layer of hydrophobic solution. The experiment was carried out on two photovoltaic collectors, of which one was considered as reference and the other one was coated with a commercial hydrophobic solution. It was studied the evolution of the following electrical parameters: current, voltage, power, efficiency and daily energy production. The voltage was almost unaffected, but for all the others parameters, important drop were recorded. The preliminary conclusion of the study is that the use of hydrophobic solutions, for the treatment of glazed surfaces of solar collectors is not recommended. This hypothesis needs supplementary investigations and measurements in the context of reduced available information concerning the optical properties of hydrophobic solutions.

  3. Optimum solar flat-plate collector slope: Case study for Helwan, Egypt

    International Nuclear Information System (INIS)

    Elminir, Hamdy K.; Ghitas, Ahmed E.; El-Hussainy, F.; Hamid, R.; Beheary, M.M.; Abdel-Moneim, Khaled M.

    2006-01-01

    This article examines the theoretical aspects of choosing a tilt angle for the solar flat-plate collectors used in Egypt and make recommendations on how the collected energy can be increased by varying the tilt angle. The first objective in this investigation is to perform a statistical comparison of three specific anisotropic models (Tamps-Coulson, Perez and Bugler) to recommend one that is general and is most accurate for estimating the solar radiation arriving on an inclined surface. Then, the anisotropic model that provides the most accurate estimation of the total solar radiation has been used to determine the optimum collector slope based on the maximum solar energy availability. This result has been compared with the results provided by other models that use declination, daily clearness index and ground reflectivity. The study revealed that Perez's model shows the best overall calculated performance, followed by the Tamps-Coulson then Bugler models

  4. Observer-Based Bilinear Control of First-Order Hyperbolic PDEs: Application to the Solar Collector

    KAUST Repository

    Mechhoud, Sarra

    2015-12-18

    In this paper, we investigate the problem of bilinear control of a solar collector plant using the available boundary and solar irradiance measurements. The solar collector is described by a first-order 1D hyperbolic partial differential equation where the pump volumetric flow rate acts as the plant control input. By combining a boundary state observer and an internal energy-based control law, a nonlinear observer based feedback controller is proposed. With a feed-forward control term, the effect of the solar radiation is cancelled. Using the Lyapunov approach we prove that the proposed control guarantees the global exponential stability of both the plant and the tracking error. Simulation results are provided to illustrate the performance of the proposed method.

  5. Effect of radiation on convective flow in a tilted solar collector filled ...

    African Journals Online (AJOL)

    user

    Keywords: Radiation, tilted solar collector, finite element method, water- alumina nanofluid. ... instead of conventional heat transfer fluids (like water). The poor heat transfer properties ... to suspend ultra fine solid particles in the fluid for improving the thermal conductivity of the fluid Hetsroni and Rozenblit (1994). These early ...

  6. Solar Collector Design Optimization: A Hands-on Project Case Study

    Science.gov (United States)

    Birnie, Dunbar P., III; Kaz, David M.; Berman, Elena A.

    2012-01-01

    A solar power collector optimization design project has been developed for use in undergraduate classrooms and/or laboratories. The design optimization depends on understanding the current-voltage characteristics of the starting photovoltaic cells as well as how the cell's electrical response changes with increased light illumination. Students…

  7. Integration between direct steam generation in linear solar collectors and supercritical carbon dioxide Brayton power cycles

    OpenAIRE

    Coco Enríquez, Luis; Muñoz Antón, Javier; Martínez-Val Peñalosa, José María

    2015-01-01

    Direct Steam Generation in Parabolic Troughs or Linear Fresnel solar collectors is a technology under development since beginning of nineties (1990's) for replacing thermal oils and molten salts as heat transfer fluids in concentrated solar power plants, avoiding environmental impacts. In parallel to the direct steam generation technology development, supercritical Carbon Dioxide Brayton power cycles are maturing as an alternative to traditional Rankine cycles for increasing net plant efficie...

  8. Photovoltaic-thermal (PV/T) solar collectors: Features and performance modelling

    International Nuclear Information System (INIS)

    Atienza-Márquez, Antonio; Bruno, Joan Carles; Coronas, Alberto; Korolija, Ivan; Greenough, Richard; Wright, Andy

    2017-01-01

    Currently, the electrical efficiency of photovoltaic (PV) solar cells ranges between 5–25%. One of the most important parameters that affects the electrical efficiency of a PV collector is the temperature of its cells: the higher temperature, the lower is the efficiency. Photovoltaic/thermal (PV/T) technology is a potential solution to ensure an acceptable solar energy conversion. The PV/T technology produces both electrical and thermal energy simultaneously. It is suitable for low temperature applications (25–40 o C) and overall efficiency increases compared to individual collectors. This paper describes an installation in a single-family house where PV/T collectors are coupled with a ground heat exchanger and a heat pump for domestic hot water and space heating purposes. The aim of this work is twofold. First, the features of the PV/T technology are analyzed. Second, a model of a flat-plate PV/T water collector was developed in TRNSYS in order to analyze collectors performance. (author)

  9. Dimensioning, construction and commissioning of a coffee beans drying system with use of solar collectors

    International Nuclear Information System (INIS)

    Mora Vindas, Allan Gerardo

    2014-01-01

    A system of low-cost solar drying of coffee beans is dimensioned, built and commissioned by using solar collectors based on recycled aluminum cans. The information is collected from literature about the drying of coffee, types of drying and the various types of solar dryers.The coffee beans drying system is conceptualized and sized based on a solar collector constructed of aluminum cans as solar radiation absorbing material. The grain drying system is then built in coffee benefit CoopeTarrazu to all provided by the company and help materials and labor facilities. A guide to implementation of solar drying technology with general information is tailored to implement, select, build and maintain a solar grain dryer in Central America. The launch of the drying system was made by checking the proper functioning of the system and measurement instruments variables selected to calculate the efficiency of the system. The drying system is tested with a load of 45 kg of coffee bean, using a flow of air through natural convection to operate the system with the exclusive use of renewable energy. The grain is drying from a humidity of 50% (b.n), up to a humidity between 11% and 13% (b.n), which is the range generally used for the safe storage of grain. Facts of solar radiation, temperature, air velocity, relative humidity and grain humidity were taken to determine the behavior of the sized system. The maximum thermal efficiency achieved by the solar collector is determined constructed of 18%, with an air flow of 0.013 kg/s and a solar radiation 1138 W/m 2 . The average drying efficiency during experimentation was 17.8%, which is among the range of efficiencies for the type of drying equipment. Best thermal efficiencies were obtained from the solar collector built that the commercial solar collector compared. Controlling the flow of air into the equipment is recommended in order to improve the thermal efficiency and drying equipment, using blowers, fans or induced draft chimney

  10. Energy and Exergy Analysis of Dual Channel Solar Air Collector with Different Absorber Plates Geometry

    Directory of Open Access Journals (Sweden)

    Najim A. Jassim

    2018-04-01

    Full Text Available Flat-plate collector considers most common types of collectors, for ease of manufacturing and low price compared with other collectors. The main aim of the present work is to increase the efficiency of the collector, which can be achieved by improving the heat transfer and minimize heat loss experimentally. Five types of solar air collectors have been tested, which conventional channel with a smooth absorber plate (model I, dual channel with a smooth absorber plate (model II, dual channel with perforating “V” corrugated absorber plate (model III, dual channel with internal attached wire mesh (model Ⅳ, and dual channel with absorber sheet of transparent honeycomb, (model Ⅴ. The dual channel collector used for increasing heat transfer area and heat removal factor to improve thermal performance. The outdoor test was conducted during the period December (2016 to February (2017 at different mass flow rates 0.0217 kg/s, 0.0271 kg/s and 0.0325 kg/s. The experiments were carried out from 8:30 AM to 3:00 PM for clear days. Experimental results show that the average thermal efficiency was (72.2 % for model (III, (40.2 % for model (I, (51.6 % for model (II, (65.1 % for model (Ⅳ and (59.7 % for model (Ⅴ. At the last part of the study, the exergy analyses were derived for both collectors. The results of this part showed that the conventional channel model (I is having largest irreversibility, and the dual channel collector model (III is having a greatest exergetic efficiency.

  11. 3X compound parabolic concentrating (CPC) solar energy collector. Final technical report

    Energy Technology Data Exchange (ETDEWEB)

    Ballheim, R.W.

    1980-04-25

    Chamberlain engineers designed a 3X compound parabolic concentrating (CPC) collector for the subject contract. The collector is a completely housed, 105.75 x 44.75 x 10.23-inch, 240-pound unit with six each evacuated receiver assemblies, a center manifold and a one-piece glass cover. A truncated version of a CPC trough reflector system and the General Electric Company tubular evacuated receiver have been integrated with a mass producible collector design suitable for operation at 250 to 450/sup 0/F. The key criterion for optimization of the design was minimization of the cost per Btu collected annually at an operating temperature of 400/sup 0/F. The reflector is a 4.1X design truncated to a total height of 8.0 inches with a resulting actual concentration ratio of 2.6 to 1. The manifold is an insulated area housing the fluid lines which connect the six receivers in series with inlet and outlet tubes extending from one side of the collector at the center. The reflectors are polished, anodized aluminum which are shaped by the roll form process. The housing is painted, galvanized steel, and the cover glass is 3/16-inch thick tempered, low iron glass. The collector requires four slope adjustments per year for optimum effectiveness. Chamberlain produced ten 3X CPC collectors for the subject contract. Two collectors were used to evaluate assembly procedures, six were sent to the project officer in Albuquerque, New Mexico, one was sent to Argonne National Laboratory for performance testing and one remained with the Company. A manufacturing cost study was conducted to estimate limited mass production costs, explore cost reduction ideas and define tooling requirements. The final effort discussed shows the preliminary design for application of a 3X CPC solar collector system for use in the Iowa State Capitol complex.

  12. Visible and infrared absorption spectra of covering materials for solar collectors

    International Nuclear Information System (INIS)

    Pelece, I.

    2008-01-01

    Use of solar energy increases every year. In Latvia, solar energy is used mainly by solar collectors. The main part of the solar collector is the absorber, but not less important is the covering material which protects the absorber from the cooling impact of the wind. This cover must be transparent for solar radiation, but opaque for thermal radiation of the absorber, which is at greater wavelengths. Therefore it is important to measure absorption spectra of possible covering materials at visible and infrared wavelength ranges. Absorption spectra have been measured for several materials: glass, polythene, Plexiglas, and cells Plexiglas. Absorption spectra for all these materials are measured in three ranges: ultraviolet-visible (UV-VIS): 250-1000 nm; near infrared (NIR): 700-110 nm; infrared (IR): 1200-8000 nm. UV-VIS spectra with the 'Ocean Optics' device HR-4000 have been measured, but NIR and IR - with 'Bruker' Furje spectrometer EQUINOX 55. Evaluation of absorption spectra showed that the most suitable material (from the considered) for covering of solar collectors is Plexiglas

  13. Design, Simulation and Experimental Investigation of a Solar System Based on PV Panels and PVT Collectors

    Directory of Open Access Journals (Sweden)

    Annamaria Buonomano

    2016-06-01

    Full Text Available This paper presents numerical and experimental analyses aimed at evaluating the technical and economic feasibility of photovoltaic/thermal (PVT collectors. An experimental setup was purposely designed and constructed in order to compare the electrical performance of a PVT solar field with the one achieved by an identical solar field consisting of conventional photovoltaic (PV panels. The experimental analysis also aims at evaluating the potential advantages of PVT vs. PV in terms of enhancement of electrical efficiency and thermal energy production. The installed experimental set-up includes four flat polycrystalline silicon PV panels and four flat unglazed polycrystalline silicon PVT collectors. The total electrical power and area of the solar field are 2 kWe and 13 m2, respectively. The experimental set-up is currently installed at the company AV Project Ltd., located in Avellino (Italy. This study also analyzes the system from a numerical point of view, including a thermo-economic dynamic simulation model for the design and the assessment of energy performance and economic profitability of the solar systems consisting of glazed PVT and PV collectors. The experimental setup was modelled and partly simulated in TRNSYS environment. The simulation model was useful to analyze efficiencies and temperatures reached by such solar technologies, by taking into account the reference technology of PVTs (consisting of glazed collectors as well as to compare the numerical data obtained by dynamic simulations with the gathered experimental results for the PV technology. The numerical analysis shows that the PVT global efficiency is about 26%. Conversely, from the experimental point of view, the average thermal efficiency of PVT collectors is around 13% and the electrical efficiencies of both technologies are almost coincident and equal to 15%.

  14. Solar collector/still for salt-water desalination. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Fonash, R L

    1983-01-01

    A combined in-line solar collector/still for the desalination of salt water was designed, built, and tested on site in the Florida Keys. During the course of the project the basic configuration was modified, as project funds permitted, to enhance performance. This collector/still utilizes sunlight for the direct heating of water and for the heating of air. The heating air is bubbled through the heated water producing desalinated water vapor which is subsequently collected. The result is non-salted water produced using sunlight.

  15. Performance Evaluation of Dual-axis Tracking System of Parabolic Trough Solar Collector

    Science.gov (United States)

    Ullah, Fahim; Min, Kang

    2018-01-01

    A parabolic trough solar collector with the concentration ratio of 24 was developed in the College of Engineering; Nanjing Agricultural University, China with the using of the TracePro software an optical model built. Effects of single-axis and dual-axis tracking modes, azimuth and elevating angle tracking errors on the optical performance were investigated and the thermal performance of the solar collector was experimentally measured. The results showed that the optical efficiency of the dual-axis tracking was 0.813% and its year average value was 14.3% and 40.9% higher than that of the eat-west tracking mode and north-south tracking mode respectively. Further, form the results of the experiment, it was concluded that the optical efficiency was affected significantly by the elevation angle tracking errors which should be kept below 0.6o. High optical efficiency could be attained by using dual-tracking mode even though the tracking precision of one axis was degraded. The real-time instantaneous thermal efficiency of the collector reached to 0.775%. In addition, the linearity of the normalized efficiency was favorable. The curve of the calculated thermal efficiency agreed well with the normalized instantaneous efficiency curve derived from the experimental data and the maximum difference between them was 10.3%. This type of solar collector should be applied in middle-scale thermal collection systems.

  16. Sensitive Analysis for the Efficiency of a Parabolic Trough Solar Collector Based on Orthogonal Experiment

    Directory of Open Access Journals (Sweden)

    Xiaoyan Liu

    2015-01-01

    Full Text Available A multitude of the researches focus on the factors of the thermal efficiency of a parabolic trough solar collector, that is, the optical-thermal efficiency. However, it is limited to a single or double factors for available system. The aim of this paper is to investigate the multifactors effect on the system’s efficiency in cold climate region. Taking climatic performance into account, an average outlet temperature of LS-2 collector has been simulated successfully by coupling SolTrace software with CFD software. Effects of different factors on instantaneous efficiency have been determined by orthogonal experiment and single factor experiment. After that, the influence degree of different factors on the collector instantaneous efficiency is obtained clearly. The results show that the order of effect extent for average maximal deviation of each factor is inlet temperature, solar radiation intensity, diameter, flow rate, condensation area, pipe length, and ambient temperature. The encouraging results will provide a reference for the exploitation and utilization of parabolic trough solar collector in cold climate region.

  17. SOLAR REFRIGERATING UNIT WITH AN ADSORPTION REACTOR AND EVACUATED TUBE COLLECTORS

    Directory of Open Access Journals (Sweden)

    M.E. Vieira

    1997-09-01

    Full Text Available This work presents the principles of operation of a solar refrigerator with the following basic components: a reactor, a set of evacuated tube solar collectors, a condenser, a heat exchanger, and an evaporator. During the heating phase, solar radiation is collected and transferred to the reactor for desorption by a vapor thermal siphon loop. During the cooling phase, heat from the reactor is released to the ambient by a second water vapor loop. Ambient data collected daily during a period of 18 years were divided into hourly values and used to simulate the temperatures of the reactor, which uses salt impregnated with graphite and ammonia, during the adsorption / desorption processes. The results show that the refrigerator operates well in Fortaleza and that better results are expected for the countryside of the state of Ceara. It is concluded that only a high efficiency collector set can be used in the system

  18. Copper corrosion and its relationship to solar collectors:a compendium.

    Energy Technology Data Exchange (ETDEWEB)

    Menicucci, David F.; Mahoney, Alan Roderick

    2007-07-01

    Copper has many fine qualities that make it a useful material. It is highly conductive of both heat and electricity, is ductile and workable, and reasonably resistant to corrosion. Because of these advantages, the solar water heating industry has been using it since the mid-1970s as the material of choice for collectors, the fundamental component of a solar water heating system. In most cases copper has performed flawlessly, but in some situations it has been known to fail. Pitting corrosion is the usual failure mode, but erosion can also occur. In 2000 Sandia National Laboratories and the Copper Development Association were asked to analyze the appearance of pin-hole leaks in solar collector units installed in a housing development in Arizona, and in 2002 Sandia analyzed a pitting corrosion event that destroyed a collector system at Camp Pendleton. This report includes copies of the reports and accounts of these corrosion failures, and provides a bibliography with references to many papers and articles that might be of benefit to the solar community. It consolidates in a single source information that has been accumulated at Sandia relative to copper corrosion, especially as it relates to solar water heaters.

  19. Effects of solar collecting area and water flow rate on the performance of a sand bed solar collector

    International Nuclear Information System (INIS)

    Maganhar, A.L.; Memon, A.H.; Panhwar, M.I.

    2005-01-01

    The often discussed renewable sources of energy have been great interest to energy researchers and planners for quite some time. The primary of renewing all sources of energy is the sun. There have been two main problems not yet fully resolved. One is the large scale production of energy and other is the cost factor. In the present study, the cost factor is under consideration. In this regard a non-conventional solar collector using indigenous material (pit sand) as solar absorber is designed and manufactured. This paper presents the results of an investigation of the effect of solar collecting area and water flow rate on the performance of a pit sand bed solar collector especially in terms of rise in water temperature. Three pit sand solar collectors of area 1m/sup 2/ each were connected in series to enhance the collecting area and the system was tested for different flow rates. Experimental results proved that there was increase in water temperature with increase in solar collecting area an decreases in water temperature with increase in flow rate. (author)

  20. Implementation of a large solar collector for electric charge generation

    Science.gov (United States)

    Leake, Skye; McGuire, Thomas; Parsons, Michael; Hirsch, Michael P.; Straub, Jeremy

    2016-05-01

    This paper evaluates use of solar flux concentrator systems with photovoltaic cells, it provides analysis on overall economic feasibility based on cost/benefit considerations. Properties evaluated include launch volume/mass, efficiency once in a functioning configuration and service life. Production time will also be discussed considering research on existing technology to expedite integration. Solar energy is primarily harvested via solar panels. With the utilization of a large mirrored dish, solar energy can be concentrated to maximize the efficiency of photovoltaic systems form a cost/benefit standpoint. The design concepts for these systems include fully rigid, tensioned over frame, and inflatable approaches. The efficiency of such systems will be discussed. Pre-existing systems, such as the photovoltaic blanket arrays on the international space station, will be considered. Areas of consideration include cost/output ratio, the efficiency of the array, and the system's service life. Prior work on ridged, tensioned, and inflatable mirrored systems will be presented.

  1. Numerical study of a modified Trombe wall solar collector system

    Directory of Open Access Journals (Sweden)

    Dragićević Snežana M.

    2009-01-01

    Full Text Available The paper presents numerical analysis of efficiency of the modified Trombe wall with forced convection. The analyzed system comprises a double glass glazing, and a massive wall with opening and central channel in it. In order to increase the efficiency, a fan is provided at the bottom vent of the wall. It is more advanced as compared with simple Trombe solar wall with a relatively low thermal resistance, which is taken as a reference in experimental analysis. The mathematical model, composed for the massive solar wall efficiency, is usually very complicated and assessment of the thermal behavior requires the use of thermal simulation techniques. This paper presents steady-state and one-dimensional mathematical model for simplified analysis of thermal efficiency of modified Trombe solar wall. The results from presented model were analyzed to predict the effects of variations in the operational parameters on the solar wall efficiency: solar radiation intensity, air velocity in the entrance duct, and room air temperature. The results have been compared with the available experimental study, and the comparison has shown satisfactory agreement. The obtained results have be used for simple and fast running design tools that designers can use in the early phases of the design process for approximate calculations of efficiency of the passive solar heating systems.

  2. Investigation of Thermal Performance of Flat Plate and Evacuated Tubular Solar Collectors According to a New Dynamic Test Method

    DEFF Research Database (Denmark)

    Kong, Weiqiang; Wang, Zhifeng; Fan, Jianhua

    2012-01-01

    obtain fluid thermal capacitance in data processing. Then theoretical analysis and experimental verification are carried out to investigate influencing factors of obtaining accurate and stable second order term. A flat plate and ETC solar collector are compared using both the new dynamic method......A new dynamic test method is introduced. This so called improved transfer function method features on two new collector parameters. One is time term which can indicate solar collector's inner heat transfer ability and the other is a second order term of collector mean fluid temperature which can...... and a standard method. The results show that the improved function method can accurately and robustly estimate these two kinds of solar collectors....

  3. Design approaches for solar industrial process-heat systems: nontracking and line-focus collector technologies

    Energy Technology Data Exchange (ETDEWEB)

    Kutscher, C.F.; Davenport, R.L.; Dougherty, D.A.; Gee, R.C.; Masterson, P.M.; May, E.K.

    1982-08-01

    The design methodology for solar industrial process heat systems is described, and an overview is given of the use of solar energy in industry. A way to determine whether solar energy makes sense for a particular application is described. The basic system configurations used to supply hot water or steam are discussed, and computer-generated graphs are supplied that allow the user to select a collector type. Detailed energy calculations are provided, including the effects of thermal losses and storage. The selection of subsystem components is described, and control systems, installation and start-up details, economics, and safety and environmental issues are explained. (LEW)

  4. Design of a system using CPC collectors to collect solar energy and to produce industrial process steam

    Energy Technology Data Exchange (ETDEWEB)

    Hsieh, C.K.

    1979-08-01

    A system has been designed to use CPC collectors to collect solar energy and to generate steam for industrial process heat purposes. The system is divided into two loops with the collectors in the collector loop to operate a preheater and the collectors in the boiler loop to heat water to elevated pressures and temperatures. A flash boiler is used to throttle the heated water to steam. Two types of CPC collectors are chosen. In the collector loop the CPC collectors are fitted with concentric tube receivers. In the boiler loop the collectors employ heat pipes to transmit heat. This design is able to alleviate the scaling and plumbing problems. A fragile receiver tube can also be employed without rupture difficulties. The thermal processes in the collectors were analyzed using a computer modeling. The results were also used to develop a thermodynamic analysis of the total system. Calculations show that the design is technically feasible. The CPC collector is shown to have an efficiency that is very weakly dependent on its operating temperatures, which makes the collector particularly attractive in high temperature applications.

  5. Solar Air Collectors for Space Heating and Ventilation Applications—Performance and Case Studies under Romanian Climatic Conditions

    Directory of Open Access Journals (Sweden)

    Sanda Budea

    2014-06-01

    Full Text Available Solar air collectors have various applications: on the one hand, they can be used for air heating in cold seasons; on the other hand they can be used in summer to evacuate the warm and polluted air from residential, offices, industrial, and commercial buildings. The paper presents experimental results of a solar collector air, under the climatic conditions of the Southeastern Europe. The relationships between the direct solar irradiation, the resulting heat flow, the air velocity at the outlet, the air flow rate, the nominal regime of the collector and the efficiency of conversion of solar energy into thermal energy are all highlighted. Thus, it was shown that after a maximum 50 min, solar air collectors, with baffles and double air passage can reach over 50% efficiency for solar irradiation of 900–1000 W/m2. The article also presents a mathematical model and the results of a computational program that allows sizing solar collectors for the transfer of air, with the purpose of improving the natural ventilation of buildings. The article is completed with case studies, sizing the area to be covered with solar collectors, to ensure ventilation of a house with two floors or for an office building. In addition, the ACH (air change per hour coefficient was calculated and compared.

  6. Experimental validation of dynamic simulation of the flat plate collector in a closed thermosyphon solar water heater

    DEFF Research Database (Denmark)

    Taherian, H.; Kolaei, Alireza Rezania; Sadeghi, S.

    2011-01-01

    This work studies the dynamic simulation of thermosyphon solar water heater collector considering the weather conditions of a city in north of Iran. The simulation was done for clear and partly cloudy days. The useful energy, the efficiency diagrams, the inlet and the outlet of collector, center...

  7. Ray-leakage-free planar solar concentrator featuring achromatic hybrid collectors and innovative secondary optical elements

    Science.gov (United States)

    Yin, Peng; Xu, Xiping; Jiang, Zhaoguo

    2017-11-01

    For high concentration ratio of the planar concentrator which is mainly used for photovoltaic or solar-thermal applications, the ray-leakage must be prevented during rays propagated in the lightguide. In this paper, the design of a ray-leakage-free planar solar concentrator is introduced with achromatic hybrid collectors and innovative secondary optical elements. The distance between two columns of dimple structures is larger because the collector width is irrelevant to the collector length, which prompts the ray-leakage-free propagating length can be raised greatly. Put differently, the proposed concentrator can obtain a high geometrical concentration ratio while achieving a high optical efficiency. To increase the ray-leakage-free propagating distance, a mathematical model between ray-leakage-free propagating length and the corresponding parameters is established, where the corresponding parameters include the parabola coefficient, the width of collector, the concentrator height and the small expanding angle of the dimple structure. Numerical results display that more than 5000x geometrical concentration ratio of the proposed concentrator is achieved without any leakage from the lightguide.

  8. ETRANS: an energy transport system optimization code for distributed networks of solar collectors

    Energy Technology Data Exchange (ETDEWEB)

    Barnhart, J.S.

    1980-09-01

    The optimization code ETRANS was developed at the Pacific Northwest Laboratory to design and estimate the costs associated with energy transport systems for distributed fields of solar collectors. The code uses frequently cited layouts for dish and trough collectors and optimizes them on a section-by-section basis. The optimal section design is that combination of pipe diameter and insulation thickness that yields the minimum annualized system-resultant cost. Among the quantities included in the costing algorithm are (1) labor and materials costs associated with initial plant construction, (2) operating expenses due to daytime and nighttime heat losses, and (3) operating expenses due to pumping power requirements. Two preliminary series of simulations were conducted to exercise the code. The results indicate that transport system costs for both dish and trough collector fields increase with field size and receiver exit temperature. Furthermore, dish collector transport systems were found to be much more expensive to build and operate than trough transport systems. ETRANS itself is stable and fast-running and shows promise of being a highly effective tool for the analysis of distributed solar thermal systems.

  9. Evaluation of the potential of optical switching materials for overheating protection of thermal solar collectors - Final report

    Energy Technology Data Exchange (ETDEWEB)

    Huot, G.; Roecker, Ch.; Schueler, A.

    2008-01-15

    Providing renewable energy for domestic hot water production and space heating, thermal solar collectors are more and more widespread, and users' expectations with respect to performance and service lifetime are rising continuously. The durability of solar collector materials is a critical point as the collector lifetime should be at least 25 years. Overheating and the resulting stagnation of the collector is a common problem with solar thermal systems. During stagnation high temperatures lead to water evaporation, glycol degradation, and stresses in the collector with increasing pressure. Special precautions are necessary to release this pressure; only mechanical solutions exist nowadays. Additionally, the occurring elevated temperatures lead to degradation of the materials that compose collectors: seals, insulation materials, and also the selective coating which is the most important part of the collector. A promising way to achieve active cooling of collectors without any mechanical device for pressure release or collector emptying is to produce a selective coating which is able to switch its optical properties at a critical temperature Tc. An optical switch allows changing the selective coating efficiency; the goal is to obtain a coating with a poor selectivity above Tc (decreasing of absorptance, increasing of emittance). Obtaining self-cooling collectors will allow increasing collector surfaces on facades and roofs in order to get high efficiency and hot water production during winter without inconvenient overheating during summer. Optical switching of materials can be obtained by many ways. Inorganic and organic thermochromic compounds, and organic thermotropic coatings are the main types of switching coatings that have been studied at EPFL-LESO-PB. Aging studies of organic thermochromic paints fabricated at EPFL suggest that the durability of organic compounds might not be sufficient for glazed metallic collectors. First samples of inorganic coatings

  10. Numerical study of desirable solar-collector orientations for the coastal region of South China

    International Nuclear Information System (INIS)

    Chow, T.T.; Chan, A.L.S.

    2004-01-01

    The overall performance of any solar energy project depends very much on the availability of solar radiation and the orientations of solar collectors. Presented in this paper is a numerical analysis of the solar irradiation received at the coastal region of South China. This region, with latitudes from 20.5 deg. N to 24 deg. N, belongs to the subtropical monsoon climatic zone. The computations were based on the typical meteorological year (TMY) weather data of Macau, compiled as a result of the ASHRAE International Weather for Energy Calculations Project. The hourly data were applied to the ESP-r building simulation program with the adoption of the Perez solar model. The analyses estimated the solar irradiation received on inclined surfaces at different orientations and slopes, and for different periods of the year. It was found that a solar collector facing the south-west direction could be most desirable for a wide range of tilt angles, and for maximizing the annual yield. The trends of variations towards other directions, tilt angles, and shorter periods of the year are also explored

  11. Thermal advantage of tracking solar collectors under Danish weather conditions

    DEFF Research Database (Denmark)

    Andersen, Elsa; Dragsted, Janne; Furbo, Simon

    2010-01-01

    . The investigations are based on calculations with a newly developed program. Measured weather data from a solar radiation measurement station at Technical University of Denmark in Kgs. Lyngby Denmark in the period 1990 to 2002 and the Danish Design Reference Year, DRY data file are used in the investigations...

  12. Technical developments of solar energy collectors in the Netherlands

    NARCIS (Netherlands)

    Oversloot, H.P.; Geus, A.C. de

    1996-01-01

    Recent research by TNO covered two different technical developments for thermal solar energy systems. One concerns a feasibility study into an all plastic spectral selective absorber, the other is a feasibility study for an overheating protection device based on heatpipe techniques. Earlier studies

  13. A Study on the Development of Nonglass Solar Vacuum Tube Collector

    International Nuclear Information System (INIS)

    Oh, Seung Jin

    2008-02-01

    Nature has been providing us energy from the beginning of the world. However human has hardly used it wisely. Solar energy is a kind of renewable energy from the nature. This study has been carried out to study the use of solar energy as it is harnessed in the form of thermal energy. Solar energy is one of the most promising energy resources such as hydrogen, biomass, wind and geothermal energy, because it is clean and inexhaustible. Space heating in buildings can be provided from solar energy by systems that are similar in many respects to water heater systems. By tapping into solar energy, we can not only solve the problem of energy shortage, but also can protect the environment and benefit the human beings. There are currently two types of evacuated tube; a single glass tube and a double glass tube. The former consists of a single glass tube which contains a flat or curved aluminium plate attached to a copper heat pipe or water flow pipe. The latter consists of rows of parallel transparent glass tubes, each of which contains an absorber tube. Evacuated tube collectors introduced above, however, pose some problems as they break rather easily under mechanical stresses. This paper introduces some preliminary results in design and fabrication of a non-glass solar vacuum tube collector in which the thermosyphon(heat pipe)made of copper is used as a heat transfer device. A series of tests have been performed to assess the ability of a non-glass solar vacuum tube collector. The series of experiments are as follows: 1)Vacuum level inside a vacuum tube. 2)Effects of the air remaining inside a vacuum tube on the temperature on the absorber plate. 3)Comparison of a non-glass vacuum solar collector with a single glass evacuated tube(SEIDO 5). Different vacuum levels inside non-glass vacuum tubes were applied to check any leakage or unexpected physical or chemical developments with time. The vacuum level changed from 10 -2 torr to 5torr in 5 days due to air infiltration from

  14. Feasibility of active solar water heating systems with evacuated tube collector at different operational water temperatures

    International Nuclear Information System (INIS)

    Mazarrón, Fernando R.; Porras-Prieto, Carlos Javier; García, José Luis; Benavente, Rosa María

    2016-01-01

    Highlights: • Analysis of the feasibility of an active solar water-heating system. • Profitability decreases as the required water temperature increases. • The number of collectors that maximizes profitability depends on the required temperature. • Investment in a properly sized system generates savings between 23% and 15%. • Fuel consumption can be reduced by 70%. - Abstract: With rapid advancements in society, higher water temperatures are needed in a number of applications. The demand for hot water presents a great variability with water required at different temperatures. In this study, the design, installation, and evaluation of a solar water heating system with evacuated tube collector and active circulation has been carried out. The main objective is to analyze how the required tank water temperature affects the useful energy that the system is capable of delivering, and consequently its profitability. The results show how the energy that is collected and delivered to the tank decreases with increasing the required temperature due to a lower performance of the collector and losses in the pipes. The annual system efficiency reaches average values of 66%, 64%, 61%, 56%, and 55% for required temperatures of 40 °C, 50 °C, 60 °C, 70 °C, and 80 °C. As a result, profitability decreases as temperature increases. The useful energy, and therefore the profitability, will decrease if the demand is not distributed throughout the day or focused on the end of the day. The system’s profitability was determined in two cases: considering maximum profitability of the system, assuming 100% utilization of useful energy (scenario 1); assuming a particular demand, considering that on many days all the useful energy the system can supply is not used (scenario 2). The analysis shows that through proper sizing of the system, optimizing the number of solar collectors, the investment in the solar system can be profitable with similar profitability values in the two

  15. Standard Practice for Evaluating Thermal Insulation Materials for Use in Solar Collectors

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1994-01-01

    1.1 This practice sets forth a testing methodology for evaluating the properties of thermal insulation materials to be used in solar collectors with concentration ratios of less than 10. Tests are given herein to evaluate the pH, surface burning characteristics, moisture adsorption, water absorption, thermal resistance, linear shrinkage (or expansion), hot surface performance, and accelerated aging. This practice provides a test for surface burning characteristics but does not provide a methodology for determining combustibility performance of thermal insulation materials. 1.2 The tests shall apply to blanket, rigid board, loose-fill, and foam thermal insulation materials used in solar collectors. Other thermal insulation materials shall be tested in accordance with the provisions set forth herein and should not be excluded from consideration. 1.3 The assumption is made that elevated temperature, moisture, and applied stresses are the primary factors contributing to the degradation of thermal insulation mat...

  16. A numerical investigation of laminar forced convection in a solar collector with non-circular duct

    Directory of Open Access Journals (Sweden)

    Teleszewski Tomasz Janusz

    2017-01-01

    Full Text Available This paper presents a two-dimensional numerical study to investigate laminar flow in a flat plate solar collector with non-circular duct (regular polygonal, elliptical, and Cassini oval shape featuring forced convection with constant axial wall heat flux and constant peripheral wall temperature (H1 condition. Applying the velocity profile obtained for the duct laminar flow, the energy equation was solved exactly for the constant wall heat flux using the Boundary Element Method (BEM. Poiseuille and Nusselt numbers were obtained for flows having a different number of geometrical factors. The results are presented and discussed in the form of tables and graphs. The area goodness factor and volume goodness factor are calculated. The predicted correlations for Poiseuille and Nusselt numbers may be a very useful resource for the design and optimization of solar collectors with non-circular ducts.

  17. Viability of use of PVC tubes in solar collectors: an analysis of materials

    Directory of Open Access Journals (Sweden)

    Luiz Guillherme Meira de Souza

    2003-06-01

    Full Text Available This paper presents a study of the inherent degradations of PVC tubes due to the thermal effect and ultraviolet solar radiation. The approach relates its causes and its effect of use of the PVC tubes as elements to absorption, forming a coil, in solar collectors for water heating. It is demonstrated that such degradations can be burst through the use of an outflow and an appropriate regimen of work, as well as of a protective layer for the tubes, in this case black ink used to magnify its absorption. The results of the properties of tubes that had been exposed to the degradation effect for up to five years are presented. The viability of use of this type of collector is demonstrated through comparative analysis of tubes exposed and not exposed to the sun, concluding for the low cost, easy assembly and maintenance of the system.

  18. A numerical investigation of laminar forced convection in a solar collector with non-circular duct

    Science.gov (United States)

    Janusz Teleszewski, Tomasz

    2017-11-01

    This paper presents a two-dimensional numerical study to investigate laminar flow in a flat plate solar collector with non-circular duct (regular polygonal, elliptical, and Cassini oval shape) featuring forced convection with constant axial wall heat flux and constant peripheral wall temperature (H1 condition). Applying the velocity profile obtained for the duct laminar flow, the energy equation was solved exactly for the constant wall heat flux using the Boundary Element Method (BEM). Poiseuille and Nusselt numbers were obtained for flows having a different number of geometrical factors. The results are presented and discussed in the form of tables and graphs. The area goodness factor and volume goodness factor are calculated. The predicted correlations for Poiseuille and Nusselt numbers may be a very useful resource for the design and optimization of solar collectors with non-circular ducts.

  19. Intelligent trend analysis for a solar thermal energy collector field

    Science.gov (United States)

    Juuso, E. K.

    2018-03-01

    Solar thermal power plants collect available solar energy in a usable form at a temperature range which is adapted to the irradiation levels and seasonal variations. Solar energy can be collected only when the irradiation is high enough to produce the required temperatures. During the operation, a trade-off of the temperature and the flow is needed to achieve a good level for the collected power. The scaling approach brings temporal analysis to all measurements and features: trend indices are calculated by comparing the averages in the long and short time windows, a weighted sum of the trend index and its derivative detects the trend episodes and severity of the trend is estimated by including also the variable level in the sum. The trend index, trend episodes and especially, the deviation index reveal early evolving changes in the operating conditions, including cloudiness and load disturbances. The solution is highly compact: all variables, features and indices are transformed to the range [-2, 2] and represented in natural language which is important in integrating data-driven solutions with domain expertise. The special situations detected during the test campaigns are explained well.

  20. Results of a study on solar collectors on primary school buildings; Resultaten onderzoek zonnepanelen op basisscholen

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2013-11-15

    A survey has been carried out among a large number of primary schools in the Netherlands with the aim to map experiences and constraints with regard to the use of solar collectors on the school buildings [Dutch] Om bestaande (succes)ervaringen en belemmeringen met betrekking tot plaatsing en gebruik van zonnepanelen in kaart te brengen, is een enquete uitgezet onder een groot aantal basisscholen in Nederland.

  1. Development and fabrication of a concentrating solar collector subsystem (quarterly reports)

    Energy Technology Data Exchange (ETDEWEB)

    1978-07-01

    Work done from January 1, 1978 through June 30, 1978, including several types of testing and results and evaluation of the structural design of the Northrup ''ML Series'' Concentrating Solar Collector, Model NSC-01-0732 and the Attitude Control System is reported. Efficiency tests, stagnation--defocusing tests, internal vacuum tests, pressure tests, tracking tests, fluttering tests, accelerated swivel and flexible joint life tests, and certification are described.

  2. Evaluation of the shape of a parabolic trough solar collector with flat null-screens

    Science.gov (United States)

    Campos-García, Manuel; Peña-Conzuelo, Andrés.; Díaz-Uribe, José Rufino

    2017-06-01

    We present a method for testing the shape quality of the reflecting surface of a parabolic trough solar collector (PTSC) with flat null-screens. We develop a custom algorithm to reconstruct the surface taking into account the differences between the normal vector of the true surface and the reference one. Also, we perform a numerical simulation to analyze the accuracy of the method by introducing controlled systematic errors such as misalignments of the null-screen or the CCD plane.

  3. Development and life cycle analysis of double slope active solar still with flat plate collector

    OpenAIRE

    A.K. Sethi; V. K. Dwivedi

    2014-01-01

    Potable water is an essential ingredient of socio-economic development and economic growth. Often water sources are brackish (i.e. contain dissolved salts) and/or contain harmful bacteria and therefore cannot be used for drinking. In addition, there are many coastal locations where seawater is abundant but potable water is not available. This study is focused on a development of solar still with flat plat collector for water desalination considered for small scale applications at ...

  4. Investigation of thermal behaviour, pressure drop, and pumping power in a Cu nanofluid-filled solar flat-plate collector

    Directory of Open Access Journals (Sweden)

    Shamshirgaran S. Reza

    2017-01-01

    Full Text Available The evaluations of the performance of solar flat-plate collectors are reported in the literature. A computer program developed by MATLAB has been applied for modelling the performance of a solar collector under steady state laminar conditions. Results demonstrate that Cu-water nanofluid would be capable of boosting the thermal efficiency of the collector by 2.4% at 4% volume concentration in the case of using Cunanofluid instead of just water as the working fluid. It is noteworthy that, dispersing the nanoparticles into the water results in a higher pressure drop and, therefore, a higher power consumption for pumping the nanofluid within the collector. It has been estimated for the collector understudy, that the increase in the pressure drop and pumping power to be around 30%.

  5. Roof-mounted solar collectors with reflectors. Evaluation; Takmonterade solfaangare med reflektorer i Aelta. Utvaerdering

    Energy Technology Data Exchange (ETDEWEB)

    Schroeder, K. [Chalmers Univ. of Technology, Goeteborg (Sweden). Monitoring Centre; Perers, B. [Vattenfall Utveckling AB, Stockholm (Sweden)

    1999-09-01

    During the spring of 1997 Solsam Sunergy AB built a solar energy plant in the Aelta residential area in Stockholm. The project was initiated in co-operation with Vattenfall Utveckling AB and the plant was built on commission from AB Nackahem. The plant was partly financed with a demonstration project support from the Swedish National Board for Industrial and Technical Development, NUTEK. The solar energy plant was built on the roofs of six 8-storey apartment buildings. On each roof there is 210 m{sup 2} conventional water-cooled solar collectors. In front of the collectors reflectors are mounted on frames formed to give optimum reflection towards the collector. The collectors are connected to a consumer substation in the basement of each building by an external culvert on the building facade. In a room adjacent to the substation there is a 12 m{sup 3} heat accumulator tank for short time storage of heat from the collectors. The plant is primarily constructed to produce domestic hot water to the apartment buildings and secondarily to feed heat to the external district distribution net to meet heat demands in other connected buildings as well as to compensate for heat losses. The Monitoring Centre at Chalmers University of Technology has studied the project during the building phase and during the solar season of 1997 in co-operation with Vattenfall Utveckling AB. This report summarises the experiences and results from the study. Several technical problems, where new solutions had to be found, caused a delay of the project by nearly a full solar season. In spite of these problems the plant was well built and it operates very well. The collected data from the monitoring were used as input to a simulation program where a parametric fitting was performed. Using the simulation program with these parameters then made it possible to predict the energy output of the plant during a normal year. The evaluation predicts that the solar heated plant of Aelta will produce about

  6. Craft-Joule Project: Stagnation proof transparently insulated flat plate solar collector (static)

    Energy Technology Data Exchange (ETDEWEB)

    Oliva, A; Cadafalch, J; Perez-Segarra, C.D. [Universitat Politecnica de Catalunya, Barcelona (Spain)] (and others)

    2000-07-01

    The STATIC (STAgnation proof Transparently Insulated flat plate Solar Collector) project is a Craft-Joule Project within the framework of the Non Nuclear Energy Programme Joule III coordinated by the Centre Technologic de Transferencia de Calor (CTTC). The core group of SMEs involved in the project has its main economical activity in the field of solar thermal systems at low temperature level (domestic hot water, solar heating, etc.). Beyond this, a large application potential exists for solar heating at medium temperature level (from 80 to 160 Celsius degrees) : industrial process heat, solar cooling and air conditioning, solar drying , distillation and desalination. Three of the four SME proposers are located in Southern Europe and in the Caribean, where a continuos increase of the demand for air conditioning and cooling has been demonstrated in the last years. The recent development of flat plate solar collectors with honeycomb-type transparent insulation cover has shown that this type of collectors can become a low cost alternative to evacuated tube and high concentrating CPC collectors in the medium temperature range from 80 to 160 Celsius degrees. With the expected reduction of collector cost, that forms 30%-50% of total system cost, a decisive break-through of solar thermal systems using heat in the medium temperature range can be achieved. The feasibility and good performance of these solar collectors has been proved in several prototypes. Nevertheless, up to now no commercial products are available. In order to reach this, the following developments of new concepts are necessary and are being carried out within this project: solution of the problem of overheating: development of collector versions for different working temperatures: optimization of the design with the support of high level numerical simulation. Several prototypes of the new solar collectors are being tested. System tests will also be carried or for two test arrays of optimized collector

  7. KARAKTERISTIK PENGERINGAN CHIPS MANGGA MENGGUNAKAN KOLEKTOR SURYA KACA GANDA [Characteristics of Mango Chips Drying Using a Double Plated Solar Collector

    Directory of Open Access Journals (Sweden)

    Safrani

    2012-12-01

    Full Text Available The objectives of this research were to study the characteristics of mango chips drying using a double plated solar collector. The materials used were sliced mangoes with the thickness of 3, 6, and 8 mm. The equipments used for this research were double plated solar collector, thermocouple, digital balance, thermometer, vacuum oven, and desiccators. The research parameters included the rate of heat energy absorbed by the double plated solar collector, the heat energy losses, the efficiency of the double plated solar collector and the moisture content of the chips. The results of this study suggested that the use of double plated solar collector could increase the temperature and the amount of heat energy, thus speed up the drying process of the mango chips. The energy needed to evaporate the moisture content in mango decreased in proportion to the increase in drying time. The difference in mango chips’ thickness resulted in different decrease rate in water content until it reached a constant state. The efficiency of the double plated solar collector was 77.82%.

  8. A numerical model for pressure drop and flow distribution in a solar collector with U-connected absorber pipes

    DEFF Research Database (Denmark)

    Bava, Federico; Furbo, Simon

    2016-01-01

    This study presents a numerical model calculating the pressure drop and flow distribution in a solar collector with U-type harp configuration in isothermal conditions. The flow maldistribution in the absorber pipes, caused by the different hydraulic resistances, was considered to evaluate...... the pressure drop across the collector. The model was developed in Matlab and is based on correlations found in literature for both friction losses and local losses, and was compared in terms of overall pressure drop against experimental measurements carried out on an Arcon Sunmark HT 35/10 solar collector...

  9. Standard Practice for Exposure of Solar Collector Cover Materials to Natural Weathering Under Conditions Simulating Stagnation Mode

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1992-01-01

    1.1 This practice covers a procedure for the exposure of solar collector cover materials to the natural weather environment at elevated temperatures that approximate stagnation conditions in solar collectors having a combined back and edge loss coefficient of less than 1.5 W/(m2 · °C). 1.2 This practice is suitable for exposure of both glass and plastic solar collector cover materials. Provisions are made for exposure of single and double cover assemblies to accommodate the need for exposure of both inner and outer solar collector cover materials. 1.3 This practice does not apply to cover materials for evacuated collectors, photovoltaic cells, flat-plate collectors having a combined back and edge loss coefficient greater than 1.5 W/(m2 ·° C), or flat-plate collectors whose design incorporates means for limiting temperatures during stagnation. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard t...

  10. New fuzzy approximate model for indirect adaptive control of distributed solar collectors

    KAUST Repository

    Elmetennani, Shahrazed

    2014-06-01

    This paper studies the problem of controlling a parabolic solar collectors, which consists of forcing the outlet oil temperature to track a set reference despite possible environmental disturbances. An approximate model is proposed to simplify the controller design. The presented controller is an indirect adaptive law designed on the fuzzy model with soft-sensing of the solar irradiance intensity. The proposed approximate model allows the achievement of a simple low dimensional set of nonlinear ordinary differential equations that reproduces the dynamical behavior of the system taking into account its infinite dimension. Stability of the closed loop system is ensured by resorting to Lyapunov Control functions for an indirect adaptive controller.

  11. Real-time dynamic analysis for complete loop of direct steam generation solar trough collector

    International Nuclear Information System (INIS)

    Guo, Su; Liu, Deyou; Chu, Yinghao; Chen, Xingying; Shen, Bingbing; Xu, Chang; Zhou, Ling; Wang, Pei

    2016-01-01

    Highlights: • A nonlinear distribution parameter dynamic model has been developed. • Real-time local heat transfer coefficient and friction coefficient are adopted. • The dynamic behavior of the solar trough collector loop are simulated. • High-frequency chattering of outlet fluid flow are analyzed and modeled. • Irradiance disturbance at subcooled water region generates larger influence. - Abstract: Direct steam generation is a potential approach to further reduce the levelized electricity cost of solar trough. Dynamic modeling of the collector loop is essential for operation and control of direct steam generation solar trough. However, the dynamic behavior of fluid based on direct steam generation is complex because of the two-phase flow in the pipeline. In this work, a nonlinear distribution parameter model has been developed to model the dynamic behaviors of direct steam generation parabolic trough collector loops under either full or partial solar irradiance disturbance. Compared with available dynamic model, the proposed model possesses two advantages: (1) real-time local values of heat transfer coefficient and friction resistance coefficient, and (2) considering of the complete loop of collectors, including subcooled water region, two-phase flow region and superheated steam region. The proposed model has shown superior performance, particularly in case of sensitivity study of fluid parameters when the pipe is partially shaded. The proposed model has been validated using experimental data from Solar Thermal Energy Laboratory of University of New South Wales, with an outlet fluid temperature relative error of only 1.91%. The validation results show that: (1) The proposed model successfully outperforms two reference models in predicting the behavior of direct steam generation solar trough. (2) The model theoretically predicts that, during solar irradiance disturbance, the discontinuities of fluid physical property parameters and the moving back and

  12. Experimental investigation and thermodynamic performance analysis of a solar dryer using an evacuated-tube air collector

    International Nuclear Information System (INIS)

    Lamnatou, Chr.; Papanicolaou, E.; Belessiotis, V.; Kyriakis, N.

    2012-01-01

    Highlights: ► We evaluate an evacuated-tube solar air collector and use it to develop a novel dryer. ► Apple, carrot and apricot thin-layer drying experiments are conducted. ► Best overall fitting among several available thin-layer drying models is pursued. ► Thermodynamic analysis yields optimal collector area, energy utilization/exergy loss. ► The proposed dryer has a capacity for drying larger quantities of products. -- Abstract: The present work presents a thermodynamic performance analysis of a solar dryer with an evacuated-tube collector. Drying experiments for apples, carrots and apricots were conducted, after a preliminary stage of the investigation which included measurements for the determination of the collector efficiency. These results showed that the warm outlet air of the collector attains temperature levels suitable for drying of agricultural products without the need of preheating. Thus, the present collector was used as the heat source for a drying chamber in the frame of the development of a novel, convective, indirect solar dryer; given the fact that in the literature there are only a few studies about this type of collectors in conjunction with solar drying applications. Thin-layer drying models were fitted to the experimental drying curves, including the recent model of Diamante et al. which showed good correlation coefficients for all the tested products. Drying parameters such as moisture ratio and drying rates were calculated. Furthermore, an energetic/exergetic analysis of the dryer was also conducted and performance coefficients such as pick-up and exergy efficiencies, energy utilization ratio, exergy losses were determined for several configurations such as single and double-trays and several drying air velocities. On the other hand, an optimal collector surface area study was conducted, based on laws for minimum entropy generation. Design parameters such as optimum collector area were determined based on the minimum entropy

  13. Solar cell module assembly jig

    Science.gov (United States)

    Ofarrell, H. W. (Inventor)

    1966-01-01

    The invention relates to the manufacture of solar cell modules and more particularly to a jig for assembling, positioning and maintaining the components under resilient pressure, while the entire assembly and the jig is subjected to heat for simultaneously soldering all of the various circuit connections; as well as structurally bonding the layers into a strong light weight structure which minimizes the tendency of the solar cells to crack and the other components and electrical connections to fracture.

  14. Nanofluid Types, Their Synthesis, Properties and Incorporation in Direct Solar Thermal Collectors: A Review.

    Science.gov (United States)

    Chamsa-Ard, Wisut; Brundavanam, Sridevi; Fung, Chun Che; Fawcett, Derek; Poinern, Gerrard

    2017-05-31

    The global demand for energy is increasing and the detrimental consequences of rising greenhouse gas emissions, global warming and environmental degradation present major challenges. Solar energy offers a clean and viable renewable energy source with the potential to alleviate the detrimental consequences normally associated with fossil fuel-based energy generation. However, there are two inherent problems associated with conventional solar thermal energy conversion systems. The first involves low thermal conductivity values of heat transfer fluids, and the second involves the poor optical properties of many absorbers and their coating. Hence, there is an imperative need to improve both thermal and optical properties of current solar conversion systems. Direct solar thermal absorption collectors incorporating a nanofluid offers the opportunity to achieve significant improvements in both optical and thermal performance. Since nanofluids offer much greater heat absorbing and heat transfer properties compared to traditional working fluids. The review summarizes current research in this innovative field. It discusses direct solar absorber collectors and methods for improving their performance. This is followed by a discussion of the various types of nanofluids available and the synthesis techniques used to manufacture them. In closing, a brief discussion of nanofluid property modelling is also presented.

  15. Nanofluid Types, Their Synthesis, Properties and Incorporation in Direct Solar Thermal Collectors: A Review

    Directory of Open Access Journals (Sweden)

    Wisut Chamsa-ard

    2017-05-01

    Full Text Available The global demand for energy is increasing and the detrimental consequences of rising greenhouse gas emissions, global warming and environmental degradation present major challenges. Solar energy offers a clean and viable renewable energy source with the potential to alleviate the detrimental consequences normally associated with fossil fuel-based energy generation. However, there are two inherent problems associated with conventional solar thermal energy conversion systems. The first involves low thermal conductivity values of heat transfer fluids, and the second involves the poor optical properties of many absorbers and their coating. Hence, there is an imperative need to improve both thermal and optical properties of current solar conversion systems. Direct solar thermal absorption collectors incorporating a nanofluid offers the opportunity to achieve significant improvements in both optical and thermal performance. Since nanofluids offer much greater heat absorbing and heat transfer properties compared to traditional working fluids. The review summarizes current research in this innovative field. It discusses direct solar absorber collectors and methods for improving their performance. This is followed by a discussion of the various types of nanofluids available and the synthesis techniques used to manufacture them. In closing, a brief discussion of nanofluid property modelling is also presented.

  16. Performance analysis of a minichannel-based solar collector using different nanofluids

    International Nuclear Information System (INIS)

    Mahian, Omid; Kianifar, Ali; Sahin, Ahmet Z.; Wongwises, Somchai

    2014-01-01

    Highlights: • Performance of a minichannel-based solar collector has been studied using four different nanofluids. • First and second law thermodynamic analyses are conducted by considering constant mass flow rate of nanofluid. • Al 2 O 3 /water nanofluids show the highest heat transfer coefficient in the tubes. • The highest outlet temperature is provided by Cu/water nanofluids. • Cu/water nanofluid produces the lowest entropy generation among the nanofluids. - Abstract: In this paper, an analytical analysis has been performed to evaluate the performance of a minichannel-based solar collector using four different nanofluids including Cu/water, Al 2 O 3 /water, TiO 2 /water, and SiO 2 /water. The analysis of first and second laws is conducted for turbulent flow by considering the constant mass flow rate of nanofluid. The results are presented for volume fractions up to 4% and nanoparticle size of 25 nm where the inner diameter of the risers of flat plate collector is assumed to be 2 mm. Analysis of the first law of thermodynamics reveals that Al 2 O 3 /water nanofluids show the highest heat transfer coefficient in the tubes while the lowest value belongs to SiO 2 /water nanofluids. The highest outlet temperature is provided by Cu/water nanofluids, and after that TiO 2 /water, Al 2 O 3 /water, and SiO 2 /water nanofluids are in ranks of second to fourth. The results of second law analysis elucidate that Cu/water nanofluid produces the lowest entropy generation among the nanofluids. It is found that although the effective thermal conductivity of TiO 2 /water nanofluids is less than Al 2 O 3 /water nanofluids, but the entropy generation of TiO 2 /water is lower than Al 2 O 3 /water. Finally, some recommendations are given for future studies on the applications of nanofluids in solar collectors

  17. Experimental analysis on a novel solar collector system achieved by supercritical CO2 natural convection

    International Nuclear Information System (INIS)

    Chen, Lin; Zhang, Xin-Rong

    2014-01-01

    Highlights: • Supercritical CO 2 flow is proposed for natural circulation solar water heater system. • Experimental system established and consists of supercritical fluid high pressure side and water side. • Stable supercritical CO 2 natural convective flow is well induced and water heating process achieved. • Seasonal solar collector system efficiency above 60% achieved and optimization discussed. - Abstract: Solar collector has become a hot topic both in scientific research and engineering applications. Among the various applications, the hot water supply demand accounts for a large part of social energy consumption and has become one promising field. The present study deals with a novel solar thermal conversion and water heater system achieved by supercritical CO 2 natural circulation. Experimental systems are established and tested in Zhejiang Province (around N 30.0°, E 120.6°) of southeast China. The current system is designed to operate in the supercritical region, thus the system can be compactly made and achieve smooth high rate natural convective flow. During the tests, supercritical CO 2 pipe flow with Reynolds number higher than 6700 is found. The CO 2 fluid temperature in the heat exchanger can be as high as 80 °C and a stable supply of hot water above 45 °C is achieved. In the seasonal tests, relative high collector efficiency generally above 60.0% is obtained. Thermal and performance analysis is carried out with the experiment data. Comparisons between the present system and previous solar water heaters are also made in this paper

  18. Standard Practice for Exposure of Cover Materials for Solar Collectors to Natural Weathering Under Conditions Simulating Operational Mode

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1995-01-01

    1.1 This practice provides a procedure for the exposure of cover materials for flat-plate solar collectors to the natural weather environment at temperatures that are elevated to approximate operating conditions. 1.2 This practice is suitable for exposure of both glass and plastic solar collector cover materials. Provisions are made for exposure of single and double cover assemblies to accommodate the need for exposure of both inner and outer solar collector cover materials. 1.3 This practice does not apply to cover materials for evacuated collectors or photovoltaics. 1.4 The values stated in SI units are to be regarded as the standard. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  19. Experimental Investigation of a Solar Greenhouse Heating System Equipped with a Parabolic Trough Solar Concentrator and a Double-Purpose Flat Plate Solar Collector

    Directory of Open Access Journals (Sweden)

    M Jafari

    2017-10-01

    Full Text Available Introduction Greenhouses provide a suitable environment in which all the parameters required for growing the plants can be controlled throughout the year. Greenhouse heating is one of the most important issues in productivity of a greenhouse. In many countries, heating costs in the greenhouses are very high, having almost 60-80% of the total production costs. In recent years, several studies have attempted to reduce the heating costs of the greenhouses by applying more energy efficient equipment and using the renewable energy sources as alternatives or supplementary to the fossil fuels. In the present study a novel solar greenhouse heating system equipped with a parabolic trough solar concentrator (PTC and a flat-plate solar collector has been developed. Therefore, the aim of this paper is to investigate the performance of the proposed heating system at different working conditions. Materials and Methods The presented solar greenhouse heating system was comprised of a parabolic trough solar concentrator (PTC, a heat storage tank, a pump and a flat plate solar collector. The PTC was constructed from a polished stainless steel sheet (as the reflector and a vacuum tube receiver. The PTC was connected to the tank by using insulated tubes and a water pump was utilized to circulate the working fluid trough the PTC and the heat exchanger installed between walls of the tank. The uncovered solar collector was located inside the greenhouse. During the sunshine time, a fraction of the total solar radiation received inside the greenhouse is absorbed by the solar collector. This rises the temperature of the working fluid inside the collector which led to density reduction and natural flow of the fluid. In other words, the collector works as a natural flow flat plate solar collector during the sunshine time. At night, when the greenhouse temperature is lower than tank temperature, the fluid flows in a reverse direction through the solar collector and the

  20. Diseño de un colector solar de placa plana; Design of a Solar Flat Plate Collector

    Directory of Open Access Journals (Sweden)

    Jeovany Rafael Rodríguez Mejía

    2015-12-01

    Full Text Available En el presente artículo se integra el uso de un software de diseño mecánico y un algoritmo de simulación de la operación de un colector solar de placa plana, con el objetivo de simplificar el proceso de diseño y manufactura de este último. Se exponen los resultados de la simulación de la operación del colector solar considerando diferentes combinaciones en los parámetros de los materiales utilizados, tales como sus propiedades y características físico químicas, además de la variación de las dimensiones del sistema adiseñar. Finalmente en el artículo se evalúa la operación de un colector solar para las condiciones climatológicas típicas de la irradiancia, velocidad de viento y temperatura ambiente a partir de una serie de curvas sinusoidales, típicas de Cuba, validándose la viabilidad del algoritmo como apoyo en la etapa de diseño y selección de materiales.In this article the use of mechanical design software and an algorithm for simulating the operation of a flat plate solar collector, with the objective of simplifying the process of design and manufacture of the latter isintegrated. The simulation results of the operation of the solar collector considering different combinations in the parameters of the materials used, such as its physicochemical properties and features in addition to thevariation of the dimensions of the system design are set. The article finally evaluates the operation of a solar collector for typical climatic conditions of irradiance, wind speed and ambient temperature from a series ofsinusoidal, typical Cuba curves is evaluated, validating the feasibility of the algorithm as support in step design and material selection.

  1. Experimental studies on a ground coupled heat pump with solar thermal collectors for space heating

    International Nuclear Information System (INIS)

    Xi, Chen; Hongxing, Yang; Lin, Lu; Jinggang, Wang; Wei, Liu

    2011-01-01

    This paper presents experimental studies on a solar-assisted ground coupled heat pump (SAGCHP) system for space heating. The system was installed at the Hebei Academy of Sciences in Shijiazhuang (lat. N38 o 03', long. E114 o 26'), China. Solar collectors are in series connection with the borehole array through plate heat exchangers. Four operation modes of the system were investigated throughout the coldest period in winter (Dec 5th to Dec 27th). The heat pump performance, borehole temperature distributions and solar colleting characteristics of the SAGCHP system are analyzed and compared when the system worked in continuous or intermittent modes with or without solar-assisted heating. The SAGCHP system is proved to perform space heating with high energy efficiency and satisfactory solar fraction, which is a promising substitute for the conventional heating systems. It is also recommended to use the collected solar thermal energy as an alternative source for the heat pump instead of recharging boreholes for heat storage because of the enormous heat capacity of the earth. -- Highlights: → We study four working modes of a solar-assisted ground coupled heat pump. → The heating performance is in direct relation with the borehole temperature. → Solar-assisted heating elevates borehole temperature and system performance. → The system shows higher efficiency over traditional heating systems in cold areas. → Solar heat is not suggested for high temperature seasonal storage.

  2. Study of a new solar adsorption refrigerator powered by a parabolic trough collector

    Energy Technology Data Exchange (ETDEWEB)

    El Fadar, A. [Energetic Laboratory, Sciences Faculty, BP 2121, 93000 Tetouan, Abdelmalek Essaadi University (Morocco); Mimet, A. [Energetic Laboratory, Sciences Faculty, BP 2121, 93000 Tetouan, Abdelmalek Essaadi University (Morocco)], E-mail: mimet@fst.ac.ma; Azzabakh, A. [Energetic Laboratory, Sciences Faculty, BP 2121, 93000 Tetouan, Abdelmalek Essaadi University (Morocco); Perez-Garcia, M. [Dpto. de Fisica Aplicada - Universidad de Almeria (Spain); Castaing, J. [Laboratoire Thermique, Energetique et Procedes (LaTEP), Avenue de l' Universite, BP 1155, 64013 Pau Cedex (France)

    2009-04-15

    This paper presents the study of solar adsorption cooling machine, where the reactor is heated by a parabolic trough collector (PTC) and is coupled with a heat pipe (HP). This reactor contains a porous medium constituted of activated carbon, reacting by adsorption with ammonia. We have developed a model, based on the equilibrium equations of the refrigerant, adsorption isotherms, heat and mass transfer within the adsorbent bed and energy balance in the hybrid system components. From real climatic data, the model computes the performances of the machine. In comparison with other systems powered by flat plate or evacuated tube collectors, the predicted results, have illustrated the ability of the proposed system to achieve a high performance due to high efficiency of PTC, and high flux density of heat pipe.

  3. Solar Pilot Plant, Phase I. Preliminary design report. Volume III. Collector subsystem. CDRL item 2

    Energy Technology Data Exchange (ETDEWEB)

    None

    1977-05-01

    The Honeywell collector subsystem features a low-profile, multifaceted heliostat designed to provide high reflectivity and accurate angular and spatial positioning of the redirected solar energy under all conditions of wind load and mirror attitude within the design operational envelope. The heliostats are arranged in a circular field around a cavity receiver on a tower halfway south of the field center. A calibration array mounted on the receiver tower provides capability to measure individual heliostat beam location and energy periodically. This information and weather data from the collector field are transmitted to a computerized control subsystem that addresses the individual heliostat to correct pointing errors and determine when the mirrors need cleaning. This volume contains a detailed subsystem design description, a presentation of the design process, and the results of the SRE heliostat test program.

  4. A Cost Effective Desalination Plant Using a Solar Chimney with Recycled Aluminum Can Collector

    Directory of Open Access Journals (Sweden)

    Singuru Rajesh

    2016-01-01

    Full Text Available The main objective of the work was to use solar energy for desalination of water. A solar chimney desalination system, which includes the solar chimney, solar collector, evaporation system, and passive condenser, was designed and built. The air enters into collector and gets heated and released at the bottom of chimney. Due to draught effect dry air goes upward. The air is humidified by spraying salt water into the hot air stream using a mistifier at the middle of chimney. Then, the partial vapours contained in the air are condensed to give desalinated water. The performance of the integrated system including power and potable water production was estimated and the results were discussed. With a 3.4 m height setup, experimental test rig was capable of evaporating 3.77 L water daily condensing 2.3 L water. It is compact in nature as it is easy to assemble and dissemble. It can be used for purifying rain water in summer under rain water harvesting. Because of using country wood, recycled Al cans, and GI sheet in fabrication, it is lower in cost.

  5. Estimation of solar collector area for water heating in buildings of Malaysia

    Science.gov (United States)

    Manoj Kumar, Nallapaneni; Sudhakar, K.; Samykano, M.

    2018-04-01

    Solar thermal energy (STE) utilization for water heating at various sectorial levels became popular and still growing especially for buildings in the residential area. This paper aims to study and identify the solar collector area needed based on the user requirements in an efficient manner. A step by step mathematical approach is followed to estimate the area in Sq. m. Four different cases each having different hot water temperatures (45°, 50°C, 55°C, and 60°C) delivered by the solar water heating system (SWHS) for typical residential application at Kuala Lumpur City, Malaysia is analysed for the share of hot and cold water mix. As the hot water temperature levels increased the share of cold water mix is increased to satisfy the user requirement temperature, i.e. 40°C. It is also observed that as the share of hot water mix is reduced, the collector area can also be reduced. Following this methodology at the installation stage would help both the user and installers in the effective use of the solar resource.

  6. The study of the heat-engineering characteristics of a solar heat collector based on aluminum heat pipes

    International Nuclear Information System (INIS)

    Khairnasov, S.M.; Zaripov, V.K.; Passamakin, B.M. et al.

    2013-01-01

    This paper presents the results of studies into the heat-engineering characteristics of a flat heat solar collector based on aluminum heat pipes that is designed to be used in building facades. The principle of work and the structure of the solar collector are considered; the results of its comparison with a traditional flat solar collector are presented. The studies were performed at a heat carrier temperature range of +10 - +30 degree C and at a solar heat flow density of 400 - 1000 W/m 2 . The obtained experimental heat-engineering characteristics of the collector based on heat pipes show that they are at a level of traditional flow solar collectors; for example, its efficiency is 0.65 - 0.73. Meanwhile, the hydraulic resistance of the structure with heat pipes is by a factor of 2 - 2.4 smaller and ensures a high level of scalability, reliability, and maintainability, which is important when using it as an element of facade constructions of solar heat systems. (author)

  7. Study on a Mid-Temperature Trough Solar Collector with Multisurface Concentration

    Directory of Open Access Journals (Sweden)

    Zhengliang Li

    2015-01-01

    Full Text Available A new trough solar concentrator which is composed of multiple reflection surfaces is developed in this paper. The concentrator was analyzed firstly by using optical software. The variation curves of the collecting efficiency affected by tracking error and the deviation angle were given out. It is found that the deviation tolerance for the collector tracking system is about 8 degrees when the receiver is a 90 mm flat. The trough solar concentrators were tested under real weather conditions. The experiment results indicate that, the new solar concentrator was validated to have relative good collecting efficiency, which can be more than 45 percent when it operated in more 145°C. It also has the characteristics of rdust, wind, and snow resistance and low tracking precision requirements.

  8. Calculated thermal performance of solar collectors based on measured weather data from 2001-2010

    DEFF Research Database (Denmark)

    Dragsted, Janne; Furbo, Simon; Andersen, Elsa

    2015-01-01

    This paper presents an investigation of the differences in modeled thermal performance of solar collectors when meteorological reference years are used as input and when mulit-year weather data is used as input. The investigation has shown that using the Danish reference year based on the period...... with an increase in global radiation. This means that besides increasing the thermal performance with increasing the solar radiation, the utilization of the solar radiation also becomes better....... 1975-1990 will result in deviations of up to 39 % compared with thermal performance calculated with multi-year the measured weather data. For the newer local reference years based on the period 2001-2010 the maximum deviation becomes 25 %. The investigation further showed an increase in utilization...

  9. The Solar Dynamic Buffer Zone (SDBZ) curtain wall: Validation and design of a solar air collector curtain wall

    Science.gov (United States)

    Richman, Russell Corey

    Given the increases in both the environmental and economic costs of energy, there is a need to design and building more sustainable and low-energy building systems now. Curtain wall assemblies show great promise---the spandrel panels within them can be natural solar collectors. By using a Solar Dynamic Buffer Zone (SDBZ) in the spandrel cavity, solar energy can be efficiently gathered using the movement of air. There is a need for a numerical model capable of predicting performance of an SDBZ Curtain Wall system. This research designed, constructed and quantified a prototype SDBZ curtain wall system through by experimental testing in a laboratory environment. The laboratory experiments focussed on three main variables: air flow through the system, incoming radiation and collector surface type. Results from the experimental testing were used to validate a one-dimensional numerical model of the prototype. Results from this research show a SDBZ curtain wall system as an effective means of reducing building heating energy consumption through the preheating of incoming exterior ventilation air during the heating season in cold climates. The numerical model showed good correlation with experimental results at higher operating flows and at lower flows when using an apparent velocity at the heat transfer boundary layer. A seasonal simulation for Toronto, ON predicted energy savings of 205 kWh/m2 with an average seasonal efficiency of 28%. This is considered in the upper range when compared to other solar air collectors. Given the lack of published literature for similar systems, this research acts to introduce a simple, innovative approach to collect solar energy that would otherwise be lost to the exterior using already existing components within a curtain wall. Specifically, the research has provided: results from experiments and simulation, a first generation numerical model, aspects of design and construction of the SDBZ curtain wall and specific directions for further

  10. Experimental Study on Performance of a Box Solar Cooker with Flat Plate Collector to Boil Water

    Science.gov (United States)

    Sitepu, T.; Gunawan, S.; Nasution, D. M.; Ambarita, H.; Siregar, R. E. T.; Ronowikarto, A. D.

    2017-03-01

    In this study, a flat plate type solar cooker is tested by exposing in solar irradiation. The objective is to examine the performance of solar cooker in boiling water. The solar cooker is a box type with collector area and height are 100 × 100 cm and 40 cm, respectively. Vessel for water is made of aluminum plate with diameter and height of 22 cm and 15 cm. The experiments are performed by varying mass of the water. It is 2 kg and 4 kg, respectively. Every experiment starts from 10:00 AM until the boiling temperature is reached. The parameters measured are radiance intensity, ambient and solar box cooker temperatures, and wind speed. The results show that the duration of water heating up to 100°C with water mass 2 kg within 2 hours 45 minutes and water mass 4 kg within 3 hours 17 minutes. The maximum temperatur of solar box cooker is 117°C at 12:56 PM and maximum efficiency is 46.30%. The main conclusion can be drawn here is that a simple solar box cooker can be used to boil water.

  11. Solar heating and cooling diode module

    Science.gov (United States)

    Maloney, Timothy J.

    1986-01-01

    A high efficiency solar heating system comprising a plurality of hollow modular units each for receiving a thermal storage mass, the units being arranged in stacked relation in the exterior frame of a building, each of the units including a port for filling the unit with the mass, a collector region and a storage region, each region having inner and outer walls, the outer wall of the collector region being oriented for exposure to sunlight for heating the thermal storage mass; the storage region having an opening therein and the collector region having a corresponding opening, the openings being joined for communicating the thermal storage mass between the storage and collector regions by thermosiphoning; the collector region being disposed substantially below and in parallel relation to the storage region in the modular unit; and the inner wall of the collector region of each successive modular unit in the stacked relation extending over the outer wall of the storage region of the next lower modular unit in the stacked relation for reducing heat loss from the system. Various modifications and alternatives are disclosed for both heating and cooling applications.

  12. Prototype Development and Evaluation of Self-Cleaning Concentrated Solar Power Collectors

    Energy Technology Data Exchange (ETDEWEB)

    Mazumder, Malay K. [Boston Univ., MA (United States); Horenstein, Mark N. [Boston Univ., MA (United States); Joglekar, Nitin R. [Boston Univ., MA (United States)

    2015-03-31

    The feasibility of integrating and retrofitting transparent electrodynamic screens (EDS) on the front surfaces of solar collectors was established as a means to provide active self-cleaning properties for parabolic trough and heliostat reflectors, solar panels, and Fresnel lenses. Prototype EDS-integrated solar collectors, including second-surface glass mirrors, metallized Acrylic-film mirrors, and dielectric mirrors, were produced and tested in environmental test chambers for removing the dust layer deposited on the front surface of the mirrors. The evaluation of the prototype EDS-integrated mirrors was conducted using dust and environmental conditions that simulate the field conditions of the Mojave Desert. Test results showed that the specular reflectivity of the mirrors could be maintained at over 90% over a wide range of dust loadings ranging from 0 to 10 g/m2, with particle diameter varying from 1 to 50 μm. The measurement of specular reflectivity (SR) was performed using a D&S Reflectometer at wavelength 660 nm. A non-contact reflectometer was designed and constructed for rapid measurement of specular reflectivity at the same wavelength. The use of this new noncontact instrument allowed us to measure SR before and after EDS activation. Several EDS prototypes were constructed and evaluated with different electrode configurations, electrode materials, and encapsulating dielectric materials.

  13. Extraction of Solar Wind Nitrogen and Noble Gases From the Genesis Gold Foil Collector

    Science.gov (United States)

    Schlutter, D. J.; Pepin, R. O.

    2005-12-01

    The Genesis gold foil is a bulk solar wind collector, integrating fluences from all three of the wind regimes. Pyrolytic extraction of small foil samples at Minnesota yielded He fluences, corrected for backscatter, in good agreement with measurements by on-board spacecraft instruments, and He/Ne elemental ratios close to those implanted in collector foils deployed on the lunar surface during the Apollo missions. Isotopic distributions of He, Ne and Ar are under study. Pyrolysis to temperatures above the gold melting point generates nitrogen blanks large enough to obscure the solar-wind nitrogen component. An alternative technique for nitrogen and noble gas extraction, by room-temperature amalgamation of the gold foil surface, will be discussed. Ne and Ar releases in preliminary tests of this technique on small foil samples were close to 100% of the amounts expected from the high-temperature pyrolysis yields, indicating that amalgamation quantitatively liberates gases from several hundred angstroms deep in the gold, beyond the implantation depth of most of the solar wind. Present work is focused on two problems currently interfering with accurate nitrogen measurements at the required picogram to sub-picogram levels: a higher than expected blank likely due to tiny air bubbles rolled into the gold sheet during fabrication, and the presence of a refractory hydrocarbon film on Genesis collector surfaces (the "brown stain") that, if left in place on the foil, shields the underlying gold from mercury attack. We have found, however, that the film is efficiently removed within tens of seconds by oxygen plasma ashing. Potential nitrogen contaminants introduced during the crash of the sample return canister are inert in amalgamation, and so are not hazards to the measurements.

  14. Roof-harvested rainwater for potable purposes: application of solar collector disinfection (SOCO-DIS).

    Science.gov (United States)

    Amin, M T; Han, M Y

    2009-12-01

    The efficiency of solar disinfection (SODIS), recommended by the World Health Organization, has been determined for rainwater disinfection, and potential benefits and limitations discussed. The limitations of SODIS have now been overcome by the use of solar collector disinfection (SOCO-DIS), for potential use of rainwater as a small-scale potable water supply, especially in developing countries. Rainwater samples collected from the underground storage tanks of a rooftop rainwater harvesting (RWH) system were exposed to different conditions of sunlight radiation in 2-L polyethylene terephthalate bottles in a solar collector with rectangular base and reflective open wings. Total and fecal coliforms were used, together with Escherichia coli and heterotrophic plate counts, as basic microbial and indicator organisms of water quality for disinfection efficiency evaluation. In the SOCO-DIS system, disinfection improved by 20-30% compared with the SODIS system, and rainwater was fully disinfected even under moderate weather conditions, due to the effects of concentrated sunlight radiation and the synergistic effects of thermal and optical inactivation. The SOCO-DIS system was optimized based on the collector configuration and the reflective base: an inclined position led to an increased disinfection efficiency of 10-15%. Microbial inactivation increased by 10-20% simply by reducing the initial pH value of the rainwater to 5. High turbidities also affected the SOCO-DIS system; the disinfection efficiency decreased by 10-15%, which indicated that rainwater needed to be filtered before treatment. The problem of microbial regrowth was significantly reduced in the SOCO-DIS system compared with the SODIS system because of residual sunlight effects. Only total coliform regrowth was detected at higher turbidities. The SOCO-DIS system was ineffective only under poor weather conditions, when longer exposure times or other practical means of reducing the pH were required for the

  15. Improved solar-collector sealants. Semiannual report, May 1981-October 1981

    Energy Technology Data Exchange (ETDEWEB)

    Scala, L.C.; Frost, L.W.; Alvino, W.M.; Bower, G.M.

    1981-10-20

    The results of a program to develop improved sealants and gaskets for use in flat plate thermal solar collectors are presented. This study includes an evaluation of six classes of polymers: EPDM, silicone, fluoroelastomer, acrylics, ethylene acrylics, chlorobutyl elastomers. Selected materials from each of the above classes were formulated and compounded. Data are presented on compound formulations, curing, screening tests and extended aging tests. In addition, information is presented on the modification of silicones and fluoroelastomers by the incorporation of new synthetic hydroxy and vinyl terminated silicones of varying molecular weight to improve low temperature compression set.

  16. Textile solar light collectors based on models for polar bear hair

    Energy Technology Data Exchange (ETDEWEB)

    Bahners, Thomas; Schlosser, Uwe; Schollmeyer, Eckhard [Deutsches Textilforschungszentrum Nord-West e.V., Adlerstr. 1, D-47798 Krefeld (Germany); Gutmann, Rainer [Institut fuer Textilchemie und Chemiefasern, Koerschtalstr. 26, D-73770 Denkendorf (Germany)

    2008-12-15

    Concepts of technical fibers following models for the polar bear hair to be used for textile solar collectors are discussed. The approach to coat fibers with a thin layer into which fluorescent dyestuff was dispersed was studied experimentally. Modified fibers made of different polymers were characterized with respect to optical properties relevant for the bionic model. In the case of poly(methylmethacrylate) fibers, the envisaged effect could be achieved to high efficiency. The optical performance could be enhanced by ultrasonic dispersion of the dyestuff in the coating matrix. The effect is less significant in semi-crystalline fibers such as poly(ethylene terephthalate), which is attributed to diffuse scattering. (author)

  17. Development of a Mathematical Lumped Parameters Model for the Heat Transfer Performance of a Solar Collector

    Directory of Open Access Journals (Sweden)

    G. Iordanou

    2011-10-01

    Full Text Available This work describes the developed of a lumped parameter model and demonstrates its practical application. The lumped parameter mathematical model is a useful instrument to be used for rapid determination of design dimensions and operational performance of solar collectors at the designing stage. Such model which incorporates data from relevant Computational Fluid Dynamics design and experimental investigations can provide an acceptable accuracy in predictions and can be used as an effective design tool. A computer algorithm validates the lumped parameter model via a window environment program.

  18. Performance Investigation and Structure Optimization of a Flat Dual-Function Solar Collector

    Directory of Open Access Journals (Sweden)

    Jinwei Ma

    2015-01-01

    Full Text Available The performance of a dual-function solar collector (DFSC that can work as either water heater or air heater depending on seasonal requirement is investigated via both experimental and numerical approaches in this paper. The numerical results are well consistent with the experimental results. Daily efficiency of the thermosiphon system with DFSC is more than 55% in water heating mode and the instantaneous air heating efficiency of the collector reaches 60%. The effects of inner parameters on the thermal efficiency of the collector are analyzed by numerical simulations of the operation of DFSC in two working modes. It is found that the depths of the two air channels in DFSC have an optimal range suitable for both working modes. The thickness of back insulation should be no less than 0.06 m to prevent heat loss via backboard, and the diameter and number of copper tubes show notable effect on the efficiency of DFSC in water heating mode but slight effect in air heating mode.

  19. The International Standards for Solar Thermal Collectors and Components as a Medium of Quality Assurance

    International Nuclear Information System (INIS)

    Alkishriwi, Nouri; Schorn, Christian A.; Theis, Danjana

    2014-01-01

    Within this publication a detailed overview about the national and international solal't1lel1nai standards is made. The various tests are described and a cross reference list for comparing the different standards is given. Moreover a certification model is presented and the advantage of third party assessment is carried out. The requirement for a solar thermal test laboratory to conduct independent third party assessment by means of an ISO/IEC17065 accreditation is given. Finally the concept of a quality system for solar thermal markets is explained and major advantages are outlined. Solar thermal systems and their components are described in various national and international standards. In Europe the standard EN12975 defines the regulations and requirements for solar thermal collectors. The standard EN12976 is established for the evaluation of factory made solar thermal systems. The EN12977 is the state of the art standard for the evaluation of custom build systems. Nowadays in Libya the standard ISO9806 for solar collectors and the standard ISO9459 for domestic water heating systems define the regulations and requirements for solar thermal collectors and systems. In the meanwhile, empowered Center for Renewable Energy and Energy Efficiency Certification Body is under construction. This body is working now to set the minimum requirements of the testing facilities of solar thermal systems. The international standard for collector testing is the ISO9806 and the standard ISO9459 Part 2, 4, 5 for domestic water heating systems. Within the year 2013 a revision of the ISO9806 will be published and, for the first time, a consistent harmonized standard for the main solar thermal markets will be set in force. Besides the various standards for solar thermal products a meaningful element for the quality assurance and the customer protection is third party certification. Third party certification involves an independent assessment, declaring that specified requirements

  20. Air/liquid collectors

    DEFF Research Database (Denmark)

    Jensen, Søren Østergaard; Olesen, Ole; Kristiansen, Finn Harken

    1997-01-01

    this kind of collectors. The modified simulation program has been used for the determination of the surplus in performance which solar heating systems with this type of solar collectors for combined preheating of ventilation air and domestic hot water will have. The simulation program and the efficiency......This report determine efficiency equations for combined air/liquid solar collectors by measurements on to different air/liquid collectors. Equations which contain all relevant informations on the solar collectors. A simulation program (Kviksol) has been modified in order to be able to handle...... equation will allow the manufactures to optimize this kind of systems....

  1. Nighttime radiative cooling potential of unglazed and PV/T solar collectors: parametric and experimental analyses

    DEFF Research Database (Denmark)

    Pean, Thibault Quentin; Gennari, Luca; Olesen, Bjarne W.

    2015-01-01

    Nighttime radiative cooling technology has been studied both by means of simulations and experiments, to evaluate its potential and to validate the existing theoretical models used to describe it. Photovoltaic/thermal panels (PV/T) and unglazed solar collectors have been chosen as case studies....... The obtained values showed a good agreement with the ones found in the literature about solar panels or other kinds of heat sinks used for radiative cooling applications. The panels provided a cooling performance per night ranging between 0.2 and 0.9 kWh/m2 of panel. The COP values (defined as the ratio....... An experimental setup has been constructed and tested during summer of 2014, at the Technical University of Denmark. The cooling performance (heat loss) has been measured simultaneously for both types of panels, installed side-by-side. The experimental results have been compared with the results from a commercial...

  2. A vacuum tube vee-trough collector for solar heating and air conditioning applications

    Science.gov (United States)

    Selcuk, M. K.

    1978-01-01

    An analysis is conducted of the performance of a vee-trough vacuum tube collector proposed for use in solar heating and cooling applications. The vee-trough reflector is a triangular sectioned, flat surfaced reflector, whose axis is laid in the East-West direction. A vacuum tube receiver placed at the bottom of the vee-trough collects solar heat most efficiently since convection is completely eliminated. Radiation losses are reduced by use of selective coatings on the absorber. Owing to its high temperature capabilities (300-400 F), the proposed scheme could also be used for power generation applications in combination with an organic Rankine conversion system. It is especially recommended for unattended pumping stations since the reflectors only require reversal once every six months.

  3. Design, simulation and optimization of a solar dish collector with spiral-coil thermal absorber

    Directory of Open Access Journals (Sweden)

    Pavlović Saša R.

    2016-01-01

    Full Text Available The efficient conversion of solar radiation into heat at high temperature levels requires the use of concentrating solar collectors. The goal of this paper is to present the optical and the thermal analysis of a parabolic dish concentrator with a spiral coil receiver. The parabolic dish reflector consists of 11 curvilinear trapezoidal reflective petals constructed by PMMA with silvered mirror layer and has a diameter of 3.8 m, while its focal distance is 2.26m. This collector is designed with commercial software SolidWorks and simulated, optically and thermally in its Flow Simulation Studio. The optical analysis proved that the ideal position of the absorber is at 2.1m from the reflector in order to maximize the optical efficiency and to create a relative uniform heat flux over the absorber. In thermal part of the analysis, the energetic efficiency was calculated approximately 65%, while the exergetic efficiency is varied from 4% to 15% according to the water inlet temperature. Moreover, other important parameters as the heat flux and temperature distribution over the absorber are presented. The pressure drop of the absorber coil is calculated at 0.07bar, an acceptable value.

  4. Thermal analysis of a solar collector consisting of V cavities for water heating; Analise termica de um coletor solar composto de cavidades V para aquecimento de agua

    Energy Technology Data Exchange (ETDEWEB)

    Moreira, Michel Fabio de Souza

    2009-03-15

    The solar water heating is carried through, in Brazil, by means of solar heaters compound for collectors flat plate of the type plate-and-pipes, devices that operate in stationary position and they do not require tracking of the sun. A compound collector for some formed V-trough concentrators can be an alternative to the conventional solar collectors flat plate. This compound collector for V-trough is considered, each one, for side-walls which are specularly reflecting surfaces associates in V (equivalent to a triangular gutter). Next to the vertex to each V-trough concentrators an absorber tube is fixed, for flow of the fluid to be heated. Interconnection of the absorbers tubes forms a similar tubular network existing in solar collectors of the type the plate and pipe. V-trough concentrators with the absorbers tubes are made use in series in the interior a prismatic box, which have one of its faces consisting by a glass covering and directed toward incidence of the solar radiation. An analysis of thermal performance of these devices operating stationary and without tracking of the sun is researched. A mathematical model for the computational simulation of the optical and thermal performance of these concentrative devices is elaborated, whose implementation was carried through software EES (Engineering Equation Solver). The efficiency optics of V-trough concentrators with cylindrical absorbers is calculated from the adaptation of the methodology used for Fraidenraich (1994), proposal for Hollands (1971) for V-trough cavities with plain absorbers. The thermal analysis of the considered collector was based on the applied methodology the CPC for Hsieh (1981) and Leao (1989). Relative results to the thermal performance of V-trough concentrators suggest that these configurations are not competitive, technique and economically, with the conventional plain collectors. Although some geometric configurations presented next thermal efficiencies to the conventional plain

  5. Simulation and parameter analysis of a two-stage desiccant cooing/heating system driven by solar air collectors

    International Nuclear Information System (INIS)

    Li, H.; Dai, Y.J.; Köhler, M.; Wang, R.Z.

    2013-01-01

    Highlights: ► A solar desiccant cooling/heating system is simulation studied. ► The mean deviation is about 10.5% for temperature and 9.6% for humidity ratio. ► The 51.7% of humidity load and 76% of the total cooling can be handled. ► About 49.0% of heating load can be handled by solar energy. ► An optimization of solar air collector has been investigated. - Abstract: To increase the fraction of solar energy might be used in supplying energy for the operation of a building, a solar desiccant cooling and heating system was modeled in Simulink. First, base case performance models were programmed according to the configuration of the installed solar desiccant system and verified by the experimental data. Then, the year-round performance about the system was simulated. Last, design parameters of solar air collectors were optimized that include collector area, air leakage and thermal insulation. Comparison between numerical and experimental results shows good agreement. During the simulation, the humidity load for 63 days (51.7%) can be totally handled by the two-stage desiccant cooling unit. For seasonal total heating load, about 49.0% can be handled by solar energy. Based on optimized results, the thermal energy subsystem functioned to its expected performance in solar energy collection and thermal storage

  6. Exergetic and Thermoeconomic Analyses of Solar Air Heating Processes Using a Parabolic Trough Collector

    Directory of Open Access Journals (Sweden)

    Miguel Ángel Hernández-Román

    2014-08-01

    Full Text Available This paper presents a theoretical and practical analysis of the application of the thermoeconomic method. A furnace for heating air is evaluated using the methodology. The furnace works with solar energy, received from a parabolic trough collector and with electricity supplied by an electric power utility. The methodology evaluates the process by the first and second law of thermodynamics as the first step then the cost analysis is applied for getting the thermoeconomic cost. For this study, the climatic conditions of the city of Queretaro (Mexico are considered. Two periods were taken into account: from July 2006 to June 2007 and on 6 January 2011. The prototype, located at CICATA-IPN, Qro, was analyzed in two different scenarios i.e., with 100% of electricity and 100% of solar energy. The results showed that thermoeconomic costs for the heating process with electricity, inside the chamber, are less than those using solar heating. This may be ascribed to the high cost of the materials, fittings, and manufacturing of the solar equipment. Also, the influence of the mass flow, aperture area, length and diameter of the receiver of the solar prototype is a parameter for increasing the efficiency of the prototype in addition to the price of manufacturing. The optimum design parameters are: length is 3 to 5 m, mass flow rate is 0.03 kg/s, diameter of the receiver is around 10 to 30 mm and aperture area is 3 m2.

  7. Spiral multiple-effect diffusion solar still coupled with vacuum-tube collector and heat pipe

    KAUST Repository

    Huang, Bin-Juine

    2015-04-01

    © 2015 Elsevier B.V. A novel solar still with spiral-shape multiple-effect diffusion unit is developed in the present study. The test results of a 14-effect unit coupled with vacuum-tube solar collector (absorber area 1.08m2) show that the highest daily pure water production is 40.6kgd-1. The measured highest productivity based on the area of glass cover, solar absorber, and evaporating surface is 34.7, 40.6, and 7.96kgm-2d-1, respectively, which are much higher than the published results. The measured solar distillation efficiency is 2.0-3.5. The performance enhancement results mainly from the lateral diffusion process in the spiraled still cell. The vapor flow generated by heat input can flow freely and laterally through the spiral channel down to the end when solar heat input is high. Besides, the larger evaporating and condensing area at the outer cell may increase heat and mass transfer at the outer cell.

  8. Heat transfer characteristics in the channel of a finned absorber solar collector; Caracteristicas da transferencia de calor no canal de um coletor solar de absorvedor aletado

    Energy Technology Data Exchange (ETDEWEB)

    Saboya, Sergio Mourao [Centro Tecnico Aeroespacial, Sao Jose dos Campos, SP (Brazil). Inst. Tecnologico de Aeronautica; Saboya, Francisco Eduardo Mourao [Universidade Federal Fluminense, Niteroi, RJ (Brazil)]. E-mails: saboya@mec.ita.cta.br; fsaboya@mec.uff.br

    2000-07-01

    Finned absorber solar collectors are devices in which plates (fins) are fixed perpendicularly to the absorber plate. The purpose of these fins is to cause the so called 'cavity effect', lowering the collector losses. This paper studies the heat transfer that occurs in the collector channel. This analysis is done using the efficiency of the collector, which is calculated solving the system of equations that govern the collector thermal behavior, and the computation of the convection heat transfer between the fluid flowing in the channel and the absorber plate. This analysis allows the calculation of design parameters such as mass flow rate and exit bulk temperature of the fluid. (author)

  9. An Experimental Study of the Thermal Performance of Solar Air Collector Inclined (75o on the Horizontal Plane

    Directory of Open Access Journals (Sweden)

    Hasasn Ali Jurmut

    2018-02-01

    Full Text Available In this paper, an experimental study of the thermal performance of the solar air collector manufactured of galvanized iron sheet with dimension 100×120cm, frame width 20cm, has holes 0.5cm arrangement on horizontal and vertical, the collector inclined at an angle (75o on the horizontal plane. All author faces of the collector (four sides and background are insulations in order to minimize the thermal losses .All the result recorded in winter season for two different days one of them sunny and the other was cloudy. The result shows the effect of the angle of collector gives more heat to the collector, hence higher outlet temperature, especially in sunny day. Maximum outlet temperature  of the collector (35.5o when inlet temperature 18o and maximum Nusselt  number(Nu at twelve o’clock of the sunny day more than the cloudy day.  At the end its high system efficiency and good collector effectiveness.

  10. Study on solar collector utilizing electro-hydrodynamical effect; Denki ryutai rikigaku koka wo riyosuru taiyo shunetsuki no kenkyu

    Energy Technology Data Exchange (ETDEWEB)

    Sato, M.; Aoki, H.; Wako, Y. [Hachinohe Institute of Technology, Aomori (Japan)

    1997-11-25

    This paper proposes a cone type electro-hydrodynamical (EHD) heat collector, describes its structure and principle, and mentions possibility of improving the heat collecting efficiency. The paper proposes a heat collector with a shape close to a cone. Trees are of cone form so that their every leaf, branch and truck can capture solar energy efficiently. Imitating this fact existing in the natural world, a cone-shaped heat collector was fabricated on a trial basis to discuss its heat collecting efficiency. Furthermore, black round stones are placed in the inner cone of the cone- shaped heat collector of double-glass structure. A low boiling point medium is placed between the inner and outer cones to cause corona discharge in vapor generated by absorbing the solar heat, and generate corona wind for an attempt to accelerate heat transfer into a heat exchanger. Thus, development was made on a cone-shaped high-efficiency heat collector utilizing electro-hydrodynamical (EHD) effect, and elucidation was given on dynamic phenomena of an electro-thermal fluid. Heat transfer in the EHD heat collector has a possibility of being accelerated by generation of ionic wind. In addition, it is thought that there would be an optimum value in applied voltage to increase electric charge supply as a result of corona discharge. 1 ref., 2 figs.

  11. A novel solar trigeneration system based on concentrating photovoltaic/thermal collectors. Part 1: Design and simulation model

    International Nuclear Information System (INIS)

    Buonomano, Annamaria; Calise, Francesco; Dentice d'Accadia, Massimo; Vanoli, Laura

    2013-01-01

    This paper analyzes the thermodynamic performance of high-temperature PhotoVoltaic/Thermal (PVT) solar collectors. The collector is based on a combination of a parabolic dish concentrating solar thermal collector and a high efficiency solar photovoltaic collector. The PVT system under investigation allows one to produce simultaneously electrical energy and high-temperature thermal energy by solar irradiation. The main aim of this study is the design and the analysis of a concentrating PVT which is able to operate at reasonable electric and thermal efficiency up to 180 °C. In fact, the PVT is designed to be integrated in a Solar Heating and Cooling system and it must drive a two-effect absorption chiller. This capability is quite new since conventional PVT collectors usually operate below 45 °C. Among the possible high-temperature PVT systems, this paper is focused on a system consisting in a dish concentrator and in a triple-junction PV layer. In particular, the prototype consists in a parabolic dish concentrator and a planar receiver. The system is equipped with a double axis tracking system. The bottom surface of the receiver is equipped with triple-junction silicon cells whereas the top surface is insulated. In order to analyze the performance of the Concentrating PVT (CPVT) collector a detailed mathematical model was implemented. This model is based on zero-dimensional energy balances on the control volumes of the system. The simulation model allows one to calculate in detail the temperatures of the main components of the system (PV layer, concentrator, fluid inlet and outlet and metallic substrate) and the main energy flows (electrical energy, useful thermal energy, radiative losses, convective losses). The input parameters of the model include all the weather conditions (temperature, insolation, wind velocity, etc.) and the geometrical/material parameters of the systems (lengths, thermal resistances, thicknesses, etc.). Results showed that both electrical

  12. Optimization of systems with the combination of ground-source heat pump and solar collectors in dwellings

    DEFF Research Database (Denmark)

    Kjellsson, Elisabeth; Hellström, Göran; Perers, Bengt

    2010-01-01

    The use of ground-source heat pumps for heating and domestic hot water in dwellings is common in Sweden. The combination with solar collectors has been introduced to reduce the electricity demand in the system. In order to analyze different systems with combinations of solar collectors and ground-source...... heat pumps, computer simulations have been carried out with the simulation program TRNSYS. Large differences were found between the system alternatives. The optimal design is when solar heat produces domestic hot water during summertime and recharges the borehole during wintertime. The advantage...... is related to the rate of heat extraction from the borehole as well as the overall design of the system. The demand of electricity may increase with solar recharging, because of the increased operating time of the circulation pumps. Another advantage with solar heat in combination with heat pumps is when...

  13. Diseño de un colector solar de placa plana; Design of a solar fl at plate collector

    Directory of Open Access Journals (Sweden)

    Jeovany Rafael Rodríguez Mejía

    2016-02-01

    Full Text Available En el presente artículo se integra el uso de un software de dis eño mecánico y un algoritmo de simulación de la operación de un colector solar de placa plana, con el objeti vo de simplificar el proceso de diseño y manufactura de este último. Se exponen los resultados de la sim ulación de la operación del colector solar considerando diferentes combinaciones en los parámetros de los materiales utilizados, tales como sus propiedades y características físico químicas, además de la var iación de las dimensiones del sistema a diseñar. Finalmente en el artículo se evalúa la operación de un colector solar para las condiciones climatológicas típicas de la irradiancia, velocidad de viento y temperatura ambiente a partir de una serie de curvas sinusoidales, típicas de Cuba, validándose la viabilidad del algoritmo como apoyo en la etapa de diseño y selección de materiales. In this article the use of mechanical design software and an al gorithm for simulating the operation of a flat plate solar collector, with the objective of simplifying the pr ocess of design and manufacture of the latter is integrated. The simulation results of the operation of the sola r collector considering different combinations in the parameters of the materials used, such as its physicochemic al properties and features in addition to the variation of the dimensions of the system design are set. The a rticle finally evaluates the operation of a solar collector for typical climatic conditions of irradiance, wind s peed and ambient temperature from a series of sinusoidal, typical Cuba curves is evaluated, validating the fe asibility of the algorithm as support in step design and material selection.

  14. Satellite Collectors of Solar Energy for Earth and Colonized Planet Habitats

    Science.gov (United States)

    Kusiolek, Richard

    Summary An array of 55,000 40-foot antennas can generate from the rays of the Sun enough electrical power to replace 50 The economic potential is huge. There are new industries that will only grow and there are different ways to collect solar energy, including wind power. The energy sources we rely on for the most part are finite - fossil fuels, coal, oil and natural gas are all limited in supply. The cost will only continue to rise as demand increases. The time of global economic crossover between the EU, Asia Pacific and North America is coming within less than five years. The biggest opportunity for solar energy entrepreneurs would seem to be in municipal contracting where 1500 40-foot stacking antennas can be hooked into a grid to power an entire city. The antenna can generate 45 kilowatts of energy, enough to satisfy the electrical needs 7x24 of ten to twenty homes. It is possible to design and build 35-by-80-foot pedestals that track the sun from morning until night to provide full efficiency. A normal solar cell looks in the sky for only four or five hours of direct sunlight. Fabrication of these pedestals would sell for USD 50, 000-70,000 each. The solar heat collected by the antennas can be bounced into a Stirling engine, creating electricity at a focal point. Water can be heated by running through that focal point. In addition, salt water passing through the focal point can be desalinated, and since the antenna can generate up to 2,000 degrees of heat at the focal point. The salt water passing through the focal point turns to steam, which separates the salt and allows the steam to be turned into fresh drinking water. Collector energy can be retained in betavoltaics which uses semiconductors to capture energy from radioactive materials and turn it into usable electricity for automobiles. In a new battery, the silicon wafers in the battery are etched with a network of deep pores. These pores vastly increase the exposure surface area of the silicon, allowing

  15. Comparative Modeling of a Parabolic Trough Collectors Solar Power Plant with MARS Models

    Directory of Open Access Journals (Sweden)

    Jose Ramón Rogada

    2017-12-01

    Full Text Available Power plants producing energy through solar fields use a heat transfer fluid that lends itself to be influenced and changed by different variables. In solar power plants, a heat transfer fluid (HTF is used to transfer the thermal energy of solar radiation through parabolic collectors to a water vapor Rankine cycle. In this way, a turbine is driven that produces electricity when coupled to an electric generator. These plants have a heat transfer system that converts the solar radiation into heat through a HTF, and transfers that thermal energy to the water vapor heat exchangers. The best possible performance in the Rankine cycle, and therefore in the thermal plant, is obtained when the HTF reaches its maximum temperature when leaving the solar field (SF. In addition, it is necessary that the HTF does not exceed its own maximum operating temperature, above which it degrades. The optimum temperature of the HTF is difficult to obtain, since the working conditions of the plant can change abruptly from moment to moment. Guaranteeing that this HTF operates at its optimal temperature to produce electricity through a Rankine cycle is a priority. The oil flowing through the solar field has the disadvantage of having a thermal limit. Therefore, this research focuses on trying to make sure that this fluid comes out of the solar field with the highest possible temperature. Modeling using data mining is revealed as an important tool for forecasting the performance of this kind of power plant. The purpose of this document is to provide a model that can be used to optimize the temperature control of the fluid without interfering with the normal operation of the plant. The results obtained with this model should be necessarily contrasted with those obtained in a real plant. Initially, we compare the PID (proportional–integral–derivative models used in previous studies for the optimization of this type of plant with modeling using the multivariate adaptive

  16. Concept design and formation of a lithium bromide–water cooling system powered by supercritical CO2 solar collector

    International Nuclear Information System (INIS)

    Chen, Lin; Chen, Yi-Min; Sun, Meng-He; Zhang, Ya-Long; Zhang, Xin-Rong

    2014-01-01

    Highlights: • Supercritical CO 2 solar collector is proposed for double effect lithium bromide–water absorption cooling system. • Coupled system concept designs are made to provide sustainable cooling capacity. • Experimental system established and tested for supercritical fluid high pressure cycle side. • Seasonal solar power lithium bromide–water cooling system COP is identified up to 1.08. - Abstract: In this study, concept design and tests for the combination of a supercritical CO 2 solar collector powered LiBr–H 2 O refrigeration system has been investigated. The system is basically consisted of one supercritical CO 2 solar collector system and one double effect lithium bromide–water absorption refrigeration cycle. The assessment of the overall performance is based on the theoretical analysis of the refrigeration cycle and experiments on a supercritical solar collector system in Shaoxing City, Zhejiang Province of China. Energy balance and seasonal efficiency analysis are developed in this study. The maximum daily averaged COP (Coefficient of Performance) of the proposed system is estimated up to 1.08, while the averaged COP ranges from 0.53 to 0.91 for different months. The obtained results indicate considerable improvement to conventional solar-assisted cooling systems. In addition, it is also found that this system performs better than traditional systems even when the solar radiation is not at high level, which is due to the stability and high efficiency of supercritical circulation collector cycle proposed. The system feasibility and possible future directions of the proposed system are also discussed in detail in this study. It is hoped that the current results can be of help to related system designs

  17. Solar dynamic power module design

    Science.gov (United States)

    Secunde, Richard R.; Labus, Thomas L.; Lovely, Ronald G.

    1989-01-01

    Studies have shown that the use of solar dynamic (SD) power for the growth areas of the Space Station Freedom program will result in life cycle cost savings when compared to power supplied by photovoltaic sources. In the SD power module, a concentrator collects and focuses solar energy into a heat receiver which has integral thermal energy storage. A Power Conversion Unit (PCU) based on the closed Brayton cycle removes thermal energy from the receiver and converts that energy to electrical energy. Since the closed Brayton cycle is a single phase gas cycle, the conversion hardware (heat exchangers, turbine, compressor, etc.) can be designed for operation in low earth orbit, and tested with confidence in test facilities on earth before launch into space. The concentrator subassemblies will be aligned and the receiver/PCU/radiator combination completely assembled and charged with gas and cooling liquid on earth before launch to, and assembly on, orbit.

  18. Thermal performance of an integrated collector storage solar water heater (ICSSWH) with phase change materials (PCM)

    International Nuclear Information System (INIS)

    Chaabane, Monia; Mhiri, Hatem; Bournot, Philippe

    2014-01-01

    Highlights: • We study the effect of phase change materials integration on the thermal performances of an ICSSWH. • Two kinds and tree radiuses of the PCM layer are studied and the most appropriate design is presented. • The use of phase change materials in ICSSWH is determined to reduce the night thermal losses. • Myristic acid is the most appropriate PCM for this application regarding the daily and night operation. - Abstract: In this paper, we propose a numerical study of an integrated collector storage solar water heater (ICSSWH). Two numerical models in three-dimensional modeling are developed. The first one which describes a sensible heat storage unit (SHSU), allowing validating the numerical model. Based on the good agreement between numerical results and experimental data from literature, and as this type of solar water heater presents the disadvantage of its high night losses, we propose to integrate a phase change material (PCM) directly in the collector and to study its effect on the ICSSWH thermal performance. Indeed, a second 3D CFD model is developed and series of numerical simulations are conducted for two kind (myristic acid and RT42-graphite) and three radiuses (R = 0.2 m, R = 0.25 m and R = 0.3 m) of this PCM layer. Numerical results show that during the day-time, the latent heat storage unit (LHSU) performs better than the sensible one when myristic acid is used as PCM. Regarding the night operating of this solar system, it is found that the LHSU is more effective for both PCMs as it allows lower thermal losses and better heat preservation

  19. A new modelling method and unified code with MCRT for concentrating solar collectors and its applications

    International Nuclear Information System (INIS)

    Cheng, Z.D.; He, Y.L.; Cui, F.Q.

    2013-01-01

    Highlights: ► A general-purpose method or design/simulation tool needs to be developed for CSCs. ► A new modelling method and homemade unified code with MCRT are presented. ► The photo-thermal conversion processes in three typical CSCs were analyzed. ► The results show that the proposed method and model are feasible and reliable. -- Abstract: The main objective of the present work is to develop a general-purpose numerical method for improving design/simulation tools for the concentrating solar collectors (CSCs) of concentrated solar power (CSP) systems. A new modelling method and homemade unified code with the Monte Carlo Ray-Trace (MCRT) method for the CSCs are presented firstly. The details of the new designing method and homemade unified code with MCRT for numerical investigations on solar concentrating and collecting characteristics of the CSCs are introduced. Three coordinate systems are used in the MCRT program and can be totally independent from each other. Solar radiation in participating medium and/or non-participating medium can be taken into account simultaneously or dividedly in the simulation. The criteria of data processing and method/code checking are also proposed in detail. Finally the proposed method and code are applied to simulate and analyze the involuted photo-thermal conversion processes in three typical CSCs. The results show that the proposed method and model are reliable to simulate various types of CSCs.

  20. Experimental testing method for solar light simulator with an attached evacuated solar collector

    OpenAIRE

    Mahmoud Shatat, Saffa Riffat, Francis Agyenim

    2013-01-01

    This paper describes a novel solar simulator of high solar irradiation. It consists of an array of 30 halogen lamps of 400W each, covering a gross area of 2.32 m2. A standardized empirical method for solar simulator testing facility based on an experimental performance is presented. A uniform geometrical configuration design for a solar simulator was evaluated by its illuminance distribution to optimize the maximum source-to-target transfer efficiency of irradiative power. Experimental tests ...

  1. Developing a theoretical model to investigate thermal performance of a thin membrane heat-pipe solar collector

    International Nuclear Information System (INIS)

    Riffat, S.B.; Zhao, X.; Doherty, P.S.

    2005-01-01

    A thin membrane heat-pipe solar collector was designed and constructed to allow heat from solar radiation to be collected at a relatively high efficiency while keeping the capital cost low. A theoretical model incorporating a set of heat balance equations was developed to analyse heat transfer processes occurring in separate regions of the collector, i.e., the top cover, absorber and condenser/manifold areas, and examine their relationship. The thermal performance of the collector was investigated using the theoretical model. The modelling predictions were validated using the experimental data from a referred source. The test efficiency was found to be in the range 40-70%, which is a bitter lower than the values predicted by modelling. The factors influencing these results were investigated

  2. Solar collectors in the Netherlands. Support from and use by consumers; Zonnepanelen in Nederland. Draagvlak en gebruik bij consumenten

    Energy Technology Data Exchange (ETDEWEB)

    Van der Lelij, B.; Visscher, J. [Motivaction, Amsterdam (Netherlands)

    2013-06-15

    A study has been carried out to determine the support and interest for private use of solar panels by the Dutch population. The focus is on the question to what extent Dutch people consider using solar panels and what the motives and barriers are with regard to applying solar collectors? Also questions were asked about the import taxes on solar collectors, produced in China. In this fact sheet the main results of the study are summarized [Dutch] Er is onderzoek gedaan naar het draagvlak en de interesse voor particulier gebruik van zonnepanelen bij de Nederlandse bevolking. De kern van het onderzoek betreft de volgende probleemstelling: In hoeverre overwegen Nederlanders zonnepanelen te gebruiken en wat zijn de motieven en drempels ten aanzien van het gebruik? Ook is een vraag gesteld over hoe men staat tegenover de importheffing op zonnepanelen uit China. In deze factsheet worden de belangrijkste resultaten van het onderzoek beschreven.

  3. Development and validation of a detailed TRNSYS-Matlab model for large solar collector fields for district heating applications

    DEFF Research Database (Denmark)

    Bava, Federico; Furbo, Simon

    2017-01-01

    This study describes the development of a detailed TRNSYS-Matlab model to simulate the behavior of a large solar collector field for district heating application. The model includes and investigates aspects which are not always considered by simpler models, such as flow distribution in the differ......This study describes the development of a detailed TRNSYS-Matlab model to simulate the behavior of a large solar collector field for district heating application. The model includes and investigates aspects which are not always considered by simpler models, such as flow distribution...... in the different rows, effect of the flow regime on the collector efficiency, thermal capacity of the components and effect of shadows from row to row. The model was compared with measurements from a solar collector field and the impact of each aspect was evaluated. A good agreement between model and measurements...... programming and computing time. Thermal capacity was worth being considered only for the bulkier components, such as the longer distribution and transmission pipes. The actual control strategy, which regulates the flow rates in the solar heating plant, was accurately reproduced in the model, as proved...

  4. Assessment of Energy, Environmental and Economic Performance of a Solar Desiccant Cooling System with Different Collector Types

    Directory of Open Access Journals (Sweden)

    Giovanni Angrisani

    2014-10-01

    Full Text Available Desiccant-based air handling units can achieve reductions in greenhouse gas emissions and energy savings with respect to conventional air conditioning systems. Benefits are maximized when they interact with renewable energy technologies, such as solar collectors. In this work, experimental tests and data derived from scientific and technical literature are used to implement a model of a solar desiccant cooling system, considering three different collector technologies (air, flat-plate and evacuated collectors. Simulations were then performed to compare the energy, environmental and economic performance of the system with those of a desiccant-based unit where regeneration thermal energy is supplied by a natural gas boiler, and with those of a conventional air-handling unit. The only solution that allows achieving the economic feasibility of the solar desiccant cooling unit consists of 16 m2 of evacuated solar collectors. This is able to obtain, with respect to the reference system, a reduction of primary energy consumption and of the equivalent CO2 emissions of 50.2% and 49.8%, respectively, but with a payback time of 20 years.

  5. Experimental investigation of forced-convection in a finned rhombic tube of the flat-plate solar collectors

    DEFF Research Database (Denmark)

    Taherian, Hessam; Yazdanshenas, Eshagh

    2006-01-01

    Due to scarcity of literature on forced-convection heat transfer in a solar collector with rhombic cross-section absorbing tubes, a series of experiments was arranged and conducted to determine heat transfer coefficient. In this study, a typical rhombic cross-section finned tube of flat...

  6. 10-MWe solar-thermal central-receiver pilot plant: collector subsystem foundation construction. Revision No. 1

    Energy Technology Data Exchange (ETDEWEB)

    1979-12-18

    Bid documents are provided for the construction of the collector subsystem foundation of the Barstow Solar Pilot Plant, including invitation to bid, bid form, representations and certifications, construction contract, and labor standards provisions of the Davis-Bacon Act. Instructions to bidders, general provisions and general conditions are included. Technical specifications are provided for the construction. (LEW)

  7. An experimental study on the application of polyalcohol solid-solid phase change materials in solar drying with cross-corrugated solar air collectors

    Science.gov (United States)

    Gao, W. F.; Lin, W. X.; Liu, T.; Li, M.

    2017-11-01

    In this paper, two identical solar driers with the same cross-corrugated solar air collectors and drying chamber were developed, one with phase-change materials (PCMs) and the other without PCMs. These two solar drying systems were tested in typical sunny and cloudy days in Kunming and their thermal performances were analyzed. The experimental results show that the temperature changing is smoother in the collector with the PCMs, which is beneficial for the drying as the useful drying time was prolonged. The same trend was also found in the chamber with the PCMs. The PCMs in solar drying system was found to play a role in temperature regulating. There were several cycles of heat charging-discharging in a cloudy testing day while the temperatures on collectors and in chambers with the polyalcohol PCMs is higher than each phase-change temperature. Nevertheless, there was only one cycle of heat charging-discharging in a sunny testing day. The collector with PCMs has higher daily useful heat gain than the collector without PCMs.

  8. Solar collectors: Is the building suited for them? Solar roof cadastre on the basis of airborne pictures; Solarkollektoren: Ist das Haus geeignet? Flugzeuge erstellen Solardachkataster

    Energy Technology Data Exchange (ETDEWEB)

    Genath, B.

    2008-07-15

    On the occasion of the commissioning of the new Vaillant solar collector factory, the senator of commerce of the German town of Gelsenkirchen made a surprising statement. He stated that the city of Gelsenkirchen is establishing a solar roof cadastre on the basis of aerial photographs which will provide information on the applicability of any given roof as a solar roof. The contribution outlines the programme and presents some details. (orig.)

  9. Output feedback control of heat transport mechanisms in parabolic distributed solar collectors

    KAUST Repository

    Elmetennani, Shahrazed

    2016-08-05

    This paper presents an output feedback control for distributed parabolic solar collectors. The controller aims at forcing the outlet temperature to track a desired reference in order to manage the produced heat despite the external disturbances. The proposed control strategy is derived using the distributed physical model of the system to avoid the loss of information due to model approximation schemes. The system dynamics are driven to follow reference dynamics defined by a transport equation with a constant velocity, which allows to control the transient behavior and the response time of the closed loop. The designed controller depends only on the accessible measured variables which makes it easy for real time implementation and useful for industrial plants. Simulation results show the efficiency of the reference tracking closed loop under different working conditions.

  10. Wind effects on convective heat loss from a cavity receiver for a parabolic concentrating solar collector

    Energy Technology Data Exchange (ETDEWEB)

    Ma, R.Y. [California State Polytechnic Univ., Pomoma, CA (United States). Dept. of Mechanical Engineering

    1993-09-01

    Tests were performed to determine the convective heat loss characteristics of a cavity receiver for a parabolid dish concentrating solar collector for various tilt angles and wind speeds of 0-24 mph. Natural (no wind) convective heat loss from the receiver is the highest for a horizontal receiver orientation and negligible with the reveler facing straight down. Convection from the receiver is substantially increased by the presence of side-on wind for all receiver tilt angles. For head-on wind, convective heat loss with the receiver facing straight down is approximately the same as that for side-on wind. Overall it was found that for wind speeds of 20--24 mph, convective heat loss from the receiver can be as much as three times that occurring without wind.

  11. Construction and testing of a test stand for solar cells and concentrating collectors

    Science.gov (United States)

    Pfeiffer, H.

    1981-11-01

    A hibrid system consisting of photovoltaic cells and parabolic concentrators was built and tested in order to study the possible cost reduction of photovoltaic systems by concentration of sunlight. The test stand comprises four parabolic tracking reflectors, a cooling circuit, electrical and thermodynamical instrumentation and an electrical water pump as a load. The solar cells are mounted in the focal line of the collectors on a cooling channel designed for optimal heat transfer and their uniform illumination is carefully adjusted. The photovoltaic generator delivers electrical energy with 9.3% efficiency at 25 C. In the hybrid regime the thermal efficiency attains 45% at a temperature of 90 C, and the electrical efficiency 6%.

  12. Optical testing of a parabolic trough solar collector by a null screen with stitching

    Science.gov (United States)

    Moreno-Oliva, V., I.; Campos-Garcia, M.; Granados-Agustin, F.; Arjona-Pérez, M. J.; Díaz-Uribe, R.; Avendaño-Alejo, M.

    2009-06-01

    In this work we report a method for testing a parabolic trough solar collector (PTSC) based on the null screen principles. For surfaces with symmetry of revolution a cylindrical null screen is used, now, for testing the PTSC we use a flat null screen. The design of the null screen with ellipsoidal spots is described; its image, which is formed by reflection on the test surface, becomes an exact square array of circular spots if the surface is perfect. Any departure from this geometry is indicative of defects on the surface. The flat null screen design and the surface evaluation algorithm are presented. Here the surface is tested in sections and the evaluation of the shape of the surface is performed with stitching method. Results of the evaluation for a square PTSC with 1000 mm by side (F/0.49) are shown.

  13. Analisa Efisiensi Prototype Solar Collector Jenis Parabolic Trough dengan Menggunakan Cover Glass Tube pada Pipa Absorber

    Directory of Open Access Journals (Sweden)

    Hartamas Ridho Prasetyo

    2015-06-01

    Full Text Available Energi tidak dapat diciptakan maupun dimusnahkan, hanya dapat dikonversikan dari satu bentuk ke bentuk lainnya (Hukum Kekekalan Energi. Energi sangat penting dalam kehidupan sehari – hari khususnya energi listrik yang kebutuhan terhadap energi ini sangat besar sedangkan sebagian besar energi listrik dihasilkan dari sumber daya fosil yang mulai menipis jumlahnya. Ketergantungan akan minyak bumi untuk jangka panjang tidak dapat di pertahankan lebih lama jika pemakaian melebihi batas wajar. Dalam Tugas Akhir ini penulis melakukan analisa alat Parabolic Trough Solar Collector dengan memanfaatkan energi radiasi matahari, yang di awali adanya perancangan desain alat PTSC dengan material yang sudah di tentukan sebelumnya. Prototype tersebut hanya bisa dilakukan pengujian dengan posisi steady state atau diam antara jam 11.30 sampai dengan 12.30 siang. Dengan adanya penelitian tentang analisa performa pada alat tersebut, telah di dapatkan beberapa hasil nilai variabel yang signifikan dan berpengaruh besar dengan nilai performa alat tersebut.

  14. Analysis of defects on the slopes on a parabolic trough solar collector with null-screens

    Science.gov (United States)

    Campos-García, Manuel; Huerta-Carranza, Oliver; Díaz-Uribe, Rufino; Moreno-Oliva, Víctor I.

    2015-09-01

    The null-screen method has been used to test aspheric surfaces, among them the surface of a parabolic trough solar collector (PTSC). This geometrical method measures the slope of the test surface and by a numerical integration procedure the shape of the test surface can be obtained. In this work, through some numerical simulations sinusoidal deformations with different amplitudes and spatial periods are introduced on PTSC surfaces. Then, an analysis of the deformations of the reflected images of a null-screen by the PTSC surface due to defects on the surface is performed. This procedure allows to validate the kind and magnitude of the surface deformations that can be measured with the proposed method. Also, an analysis of the advantages and limitations of the null-screen testing method will be discussed.

  15. High-efficiency ventilation and heating systems by means of solar air collectors for industry building refurbishment

    OpenAIRE

    Benoit Sicre; Patrick Baumann

    2015-01-01

    For the purpose of energy conservation, modern buildings are becoming more and more air-tight and generally rely on a mechanical ventilation system. According to the literature, solar air heating systems can contribute in a cost-effective way to the heating and ventilation of utility buildings. Especially cost-efficient, unglazed, façade-integrated solar air collectors seem to be an attractive new market for façade renovation. To demonstrate the technical feasibility of generating heating ene...

  16. Integration of liquid-cooled solar collectors into building walls; Gebaeudeintegration von Sonnenkollektoren mit Fluessigkeitskuehlung

    Energy Technology Data Exchange (ETDEWEB)

    Janssen, S.; Rockendorf, G.; Bartelsen, B. [Institut fuer Solarenergieforschung GmbH Hameln/Emmerthal (ISFH), Emmerthal (Germany)

    1998-02-01

    Three different methods are presented how to integrate active solar thermal components into building facades. The solar thermal absorber acts as overheating protection and the heat produced can be utilized further. The lower annual yield in comparison to roof-mounted installations is counterbalanced by a more uniform solar gain and an improved wall insulation. The new concept of elastomer-metal-absorbers can be realized in different configurations and material combinations and offers attractive options for collector installation. The methods discussed hold the promise of significant cost reductions. (orig.) [Deutsch] Es werden drei Methoden vorgestellt, aktive solarthermische Komponenten mit Fluessigkeit als Waermetraeger in die Gebaeudehuelle zu integrieren. Dabei dient der solarthermische Absorber als Ueberhitzungsschutz und die abgefuehrte Waerme kann einer Nutzung zugefuehrt werden. Der geringere jaehrliche Waermeertrag im Vergleich zur Dachmontage wird durch ein gleichmaesssiges Ertragsprofil und eine verbesserte Waermedaemmung weitgehend ausgeglichen. Das neu entwickelte Elastomer-Metall-Absorber-Konzept (EMA-Konzept) ist in unterschiedliche Konfigurationen und Materialkombinationen umsetzbar und eroeffnet attraktive Moeglichkeiten der Kollektorinstallation. Die diskutierten Methoden lassen eine deutliche Kostenersparnis erwarten. (orig.)

  17. Small-Sized Parabolic Trough Collector System for Solar Dehumidification Application: Design, Development, and Potential Assessment

    Directory of Open Access Journals (Sweden)

    Ghulam Qadar Chaudhary

    2018-01-01

    Full Text Available The current study presents a numerical and real-time performance analysis of a parabolic trough collector (PTC system designed for solar air-conditioning applications. Initially, a thermodynamic model of PTC is developed using engineering equation solver (EES having a capacity of around 3 kW. Then, an experimental PTC system setup is established with a concentration ratio of 9.93 using evacuated tube receivers. The experimental study is conducted under the climate of Taxila, Pakistan in accordance with ASHRAE 93-1986 standard. Furthermore, PTC system is integrated with a solid desiccant dehumidifier (SDD to study the effect of various operating parameters such as direct solar radiation and inlet fluid temperature and its impact on dehumidification share. The experimental maximum temperature gain is around 5.2°C, with the peak efficiency of 62% on a sunny day. Similarly, maximum thermal energy gain on sunny and cloudy days is 3.07 kW and 2.33 kW, respectively. Afterwards, same comprehensive EES model of PTC with some modifications is used for annual transient analysis in TRNSYS for five different climates of Pakistan. Quetta revealed peak solar insolation of 656 W/m2 and peak thermal energy 1139 MJ with 46% efficiency. The comparison shows good agreement between simulated and experimental results with root mean square error of around 9%.

  18. Optical and thermal testing of convection reduction mechanisms in a new 1.2X CPC solar collector

    Science.gov (United States)

    Carvalho, Maria J.; Collares-Pereira, Manuel; de Oliveira, Joao C.; Mendes, Joao F.; Haeberle, A.; Wittwer, Volker

    1994-09-01

    A new non-evacuated solar collector of the CPC type, developed and manufactured in Portugal, is now commercially available. Its design features are unique and deserve a careful study, both of its optical and of its thermal characteristics. The optics is interesting given the unusual shape and the opportunity to test different convection suppression schemes and determine their impacts on the collector's optical performance. As for the collector's thermal behavior it is very interesting to test how simple (and potential marketable) different convection suppression ideas can improve an already very good collector from the heat loss point of view (FUL equals 4.0 W/( degree(s)C.m2)). In the course of the paper a brief description of the collector is given and testing results are presented for the testing carried out in the following situations: (1) (i) measurement of its optical and thermal performance (instantaneous efficiency curve) measured both in E.W. and N.S. collector orientation (the collector has a very wide acceptance angle allowing it to work in N.S. orientation and, thus, function in a thermosyphon mode like any regular flat plate collector, (ii) measurement of its angular acceptance function; (2) measurement of the instantaneous efficiency curve after the introduction of (i) a thin Teflon high transmissivity film below the glass cover, (ii) transparent insulation of the capillary type, inserted also under the glass cover, (iii) measurement of the acceptance angle function in this last situation. In this paper it is shown that the addition of the film reduces the heat loss coefficient by a factor of 1.3 W/( degree(s)C.m2) and the transparent insulation leads only to an improvement of 1.0 W/( degree(s)C.m2) in that same coefficient.

  19. Preliminary results of heat retention in an integrated collector-storage solar water heater

    Energy Technology Data Exchange (ETDEWEB)

    Madhlopa, A. [Malawi Polytechnic, Blantyre 3 (Malawi). Dept. of Physics and Biochemical Sciences

    2004-07-01

    Integrated collector-storage solar water (ICSSW) heaters are generally more cost effective than systems with separate collector and storage units. However, ICS solar water heaters lose a substantial proportion of the captured heat during periods of low insolation or noncollection. In this study, an ICS solar water heater with two horizontal cylindrical tanks (made of galvanized steel, with a capacity of 61.8 litres each) was designed, constructed and tested. The two tanks were parallel to each other, and horizontally and vertically spaced out, with the lower tank fitted directly below a glass cover, and half of the upper tank insulated. In addition, a truncated stationary parabolic concentrator was fitted below the tanks, with its focal line along the axis of the upper tank. The system was installed outdoor (facing north) on top of a horizontal flat concrete roof at the Malawi Polytechnic (15 48' S, 35 02' E) in Malawi. It was tested with the two tanks aligned east-west, and in parallel (P) and series (S) connections. For the series-tank interconnection, the two tanks were connected with: a) one insulated hose pipe (12.7 mm diameter) from the top part of the lower tank to the bottom part of the upper tank (S1-tank interconnection) and b) two insulated hose pipes of which one pipe linked the bottom part of the lower tank to the bottom part of the upper tank while the other pipe linked the top part of the lower tank to the top part of the upper tank (S2-tank interconnection). The solar collection process was monitored from 06:00 to 17:00 hrs local time, and hot water was stored from 17:00 to 06:00 hrs the next day, without any draw-off for a sequence of 4 days. Meteorological measurements were taken during the day (06:00 to 17:00 hrs). Results show that the S2-tank interconnection yielded the most satisfactory results. In this connection configuration, the system stored 28.7 to 39.7 % of the collected thermal energy for use the next morning, comparable with

  20. A solar module fabrication process for HALE solar electric UAVs

    Energy Technology Data Exchange (ETDEWEB)

    Carey, P.G.; Aceves, R.C.; Colella, N.J.; Williams, K.A. [Lawrence Livermore National Lab., CA (United States); Sinton, R.A. [Private Consultant, San Jose, CA (United States); Glenn, G.S. [Spectrolab, Inc., Sylmar, CA (United States)

    1994-12-12

    We describe a fabrication process used to manufacture high power-to-weight-ratio flexible solar array modules for use on high-altitude-long-endurance (HALE) solar-electric unmanned air vehicles (UAVs). These modules have achieved power-to-weight ratios of 315 and 396 W/kg for 150{mu}m-thick monofacial and 110{mu}m-thick bifacial silicon solar cells, respectively. These calculations reflect average module efficiencies of 15.3% (150{mu}m) and 14.7% (110{mu}m) obtained from electrical tests performed by Spectrolab, Inc. under AMO global conditions at 25{degrees}C, and include weight contributions from all module components (solar cells, lamination material, bypass diodes, interconnect wires, and adhesive tape used to attach the modules to the wing). The fabrication, testing, and performance of 32 m{sup 2} of these modules will be described.

  1. Comparison of the effects of Al2O3 and CuO nanoparticles on the performance of a solar flat-plate collector

    Science.gov (United States)

    Munuswamy, Dinesh Babu; Madhavan, Venkata Ramanan; Mohan, Mukunthan

    2015-12-01

    To improve the efficiency of solar flat-plate collectors further, a study had been carried out wherein the conventional working fluid was replaced by nanofluids. A 25-L/day solar flat-plate water heater with collector area of 0.5 {m}^2 has been designed and fabricated. The thermosyphon system of the solar water heater was monitored at 15 locations using T-type thermocouples. Alumina and CuO nanoparticles were synthesized and characterized using Brunauer-Emmett-Teller and X-ray diffraction techniques and dispersed using ultrasonic mechanism. To stabilize the system at an optimum level, the collector is operated with volume fractions of 0.2% and 0.4% of synthesized Al2O3 and CuO nanoparticles mixed with distilled water and used in the solar flat-plate collector. The temperature profile was compared with different volume fractions of the nanoparticles in the flowing medium. Enhanced heat transfer was observed in the solar flat-plate collector using nanoparticles, and hence, it is inferred that addition of nanoparticles improves the efficiency of the solar water heaters. This paper details the temperature profile observed in the collectors, variation of insolation over the day, and change in efficiency both on the primary side (collector) and on the secondary side (storage tank) of the solar water heater.

  2. Numerical model of simulation for solar collector of water heating; Modelo de simulaco numerica para colector solar de aquecimento de agua

    Energy Technology Data Exchange (ETDEWEB)

    Silva, A. C. G. C.; Dutra, J. C. C.; Henriquez, J. R.; Michalewicz, J. S.

    2008-07-01

    Before being installed a solar heater, It must be tested, numerical or experimentally to get his characteristic equation, which is the efficiency curve, plotted as a function on the temperature of entry and solar incident radiation on the collector. In this work was developed a tool for numerical simulation of heating water flat-plate solar collectors. This tool has been developed from a mathematical model which is composed of a system of equations. In the model are included equations of balance energy for the collector, equation of the first law, the law of cooling equation of Newton, convective heat transfer coefficient correlations, equations for calculating the solar incident radiation, and one equation that calculates of the water flow due to the siphon effect. The solution of the equations system was obtained by the multidimensional version of the Newton-Raphson method. the model was validated with experimental data from literature. The results shows, that it is a very interesting tool to simulate efficiency curve of the solar collector. (Author)

  3. Thermodynamic methodology for the design of solar dryers operated with flat solar collectors; Metodologia termodinamica para el diseno de secadores operados con calentadores solares planos

    Energy Technology Data Exchange (ETDEWEB)

    Torres Reyes, Ernestina; Navarrete Gonzalez, Jose L; Ibarra Salazar, Beatriz A; Picon Nunez, Martin [Instituto de Investigaciones Cientificas, Universidad de Guanajuato, Guanjuato, Guanajuato (Mexico)

    2000-07-01

    In this paper a thermal performance analysis of solar drying process at operating varying conditions is presented. It is described semi-empirical models to thermal characterization of an experimental device. A simulator of thermal performance for operating varying conditions was developed as a part of the procedure of thermal design of solar dryers. On the other hand, it is described a simplified method to design solar collectors based on the determination of minimum entropy generation during the thermal conversion of the solar device by using the thermal analysis procedure established and the method derived of the second law of the Thermodynamics are finally presented. [Spanish] En este trabajo se presenta el analisis termico del comportamiento del sistema -colector solar camara de secado-. Se describen los modelos semi-empiricos con los que se caracterizo termicamente un secador solar experimental del tipo indirecto. Se presenta tambien un procedimiento de diseno de equipo de secado que toma en cuenta las condiciones variables de operacion que presentan los dispositivos solares. Por otro lado se describe un procedimiento simplificado de diseno, basado en un analisis derivado de la segunda ley de la Termodinamica. Esta metodologia se fundamenta en la minima generacion de entropia durante la conversion termica de la energia solar, utilizando colectores solares planos. Finalmente se presentan los resultados del diseno preliminar de equipo de secado utilizando los dos procedimientos mencionados.

  4. The impact of the hot tap water load pattern in the industrial hall on the energy yield from solar collectors

    Science.gov (United States)

    Fidorów-Kaprawyl, Natalia; Dudkiewicz, Edyta

    2017-11-01

    The systems using solar energy, popular in Poland, can be used to supply hot water for the installation used by employees of industrial halls. In manufacturing plants, employing a large number of people, the demand for hot water is practically constant throughout the year and is characterized by periodic use at the end of each work shift. Dynamics of the hot water consumption depends on the number of shifts as well as working days and holidays. Additionally the maximum hot tap water demand occurs in the whole period of installation operation. In polish climatic conditions the solar collectors' systems have the largest capacity in the summer, while in winter they need to be assisted. Beside that the supply of renewable energy is uneven and depends on weather conditions. In the paper the one-hour step analysis concerning the dependence of the load pattern of the hot tap water preparation system on the energy yield from solar collectors had been performed.

  5. Roof Integrated Solar Absorbers: The Measured Performance of ''Invisible'' Solar Collectors: Preprint

    International Nuclear Information System (INIS)

    Colon, C. J.; Merrigan, T.

    2001-01-01

    The Florida Solar Energy Center (FSEC), with the support of the National Renewable Energy Laboratory, has investigated the thermal performance of solar absorbers that are an integral, yet indistinguishable, part of a building's roof. The first roof-integrated solar absorber (RISA) system was retrofitted into FSEC's Flexible Roof Facility in Cocoa, Florida, in September 1998. This ''proof-of-concept'' system uses the asphalt shingle roof surface and the plywood decking under the shingles as an unglazed solar absorber. Data was gathered for a one-year period on the system performance. In Phase 2, two more RISA prototypes were constructed and submitted for testing. The first used the asphalt shingles on the roof surface with the tubing mounted on the underside of the plywood decking. The second prototype used metal roofing panels over a plywood substrate and placed the polymer tubing between the plywood decking and the metal roofing. This paper takes a first look at the thermal performance results for the ''invisible'' solar absorbers that use the actual roof surface of a building for solar heat collection

  6. Control of Hyperbolic Heat Transfer Mechanisms Application to the Distributed Concentrated Solar Collectors

    KAUST Repository

    Elmetennani, Shahrazed

    2017-04-01

    This dissertation addresses the flow control problem in hyperbolic heat transfer mechanisms. It raises in concentrated distributed solar collectors to enhance their production efficiency under the unpredictable variations of the solar energy and the external disturbances. These factors which are either locally measured (the solar irradiance) or inaccessible for measurement (the collectors’ cleanliness) affect the source term of the distributed model and represent a major difficulty for the control design. Moreover, the temperature in the collector can only be measured at the boundaries. In this dissertation, we propose new adaptive control approaches to provide the adequate level of heat while coping with the unpredictable varying disturbances. First, we design model based control strategies for a better efficiency, in terms of accuracy and response time, with a relatively reduced complexity. Second, we enhance the controllers with on-line adaptation laws to continuously update the efficient value of the external conditions. In this study, we approach the control problem using both, the infinite dimensional model (late lumping) and a finite dimensional approximate representation (early lumping). For the early lumping approach, we introduce a new reduced order bilinear approximate model for system analysis and control design. This approximate state representation is then used to derive a nonlinear state feedback resorting to Lyapunov stability theory. To compensate for the external disturbances and the approximation uncertainties, an adaptive controller is developed based on a phenomenological representation of the system dynamics. For the late lumping approach, we propose two PDE based controllers by stabilization of the reference tracking error distributed profile. The control laws are explicitly defined as functions of the available measurement. The first one is obtained using a direct approach for error stabilization while the second one is derived through a

  7. Impact of different improvement measures on the thermal performance of a solar collector field for district heating

    DEFF Research Database (Denmark)

    Bava, Federico; Furbo, Simon

    2018-01-01

    The paper describes the impact of different measures to improve the thermal performance of a solar heating plant for district heating applications. The impact of the different measures was evaluated through a validated TRNSYS-Matlab model. The model included details such as effect of the flow...... regime in the absorber pipes on the collector efficiency, flow distribution in the collector field, thermal capacity of the pipes and shadows from row to row. The improvement measures included variation of the operating temperatures, accurate input to the control strategy, feedback control on the outlet...... temperature of the collector field, control strategy based on weather forecast and use of different heat transfer fluids. The results showed that accurate input to the control strategy improved the yearly energy output of the plant by about 3%. If accurate input is not technically or economically feasible...

  8. Development of stable current collectors for large area dye-sensitized solar cells

    Science.gov (United States)

    Pereira, Ana Isabel; Martins, Jorge; Tavares, Carlos José; Andrade, Luísa; Mendes, Adélio

    2017-11-01

    The substrate sheet resistance effect in a large area dye-sensitized solar cell (DSC) device is still the main factor responsible for low energy conversion efficiencies. In this work, current collectors made of metal lines were applied by magnetron sputtering on a transparent conducting glass substrate. The introduction of these metal lines enabled a decrease in the sheet resistance from 7.26 Ω·□-1 to 2.52 Ω·□-1, by depositing an optimized 1.0 μm tungsten thick layer on the top of 1.5 μm thick molybdenum lines. These Mo/W lines withstanded long-term stability when in contact with iodide/triiodide redox couple. Large area dye-sensitized solar cells with 36 cm2 of active area were assembled and the power conversion efficiency increased from 0.54% to 1.62% when ten metal lines were applied in both electrodes. As a final design, Mo/W lines were only applied onto the counter-electrode and protected with an indium-tin oxide layer; the resulting device showed a power conversion efficiency of 3.43%, compared with the reference efficiency of 2.38%.

  9. Design of a nanopatterned long focal-length planar focusing collector for concentrated solar power

    Science.gov (United States)

    Ding, Qing; Choubal, Aakash; Toussaint, Kimani C.

    2017-02-01

    Concentrated solar power (CSP) facilities heavily utilize parabolic troughs to collect and concentrate sunlight onto receivers that deliver solar thermal energy to heat engines for generating electricity. However, parabolic troughs are bulky and heavy and result in a large capital investment for CSP plants, thereby making it difficult for CSP technology to be competitive with photovoltaics. We present the design of a planar focusing collector (PFC) with focal length beyond the micron scale. The PFC design is based on the use of a nanostructured silver surface for linearly polarized singlewavelength light. The designed PFC consists of metallic nanogrooves on a dielectric substrate. The geometric properties, namely the width and depth, of a single-unit nanogroove allows for full control of the optical phase at desired spatial coordinates along the nanogroove short-axis for a single wavelength. Moreover, we show numerically that such phase control can be used to construct a phase front that mimics that of a cylindrical lens. In addition, we determine the concentration ratio by comparing the width of our PFC design to the cross-sectional width of its focal spot. We also determine the conversion efficiency at long focal lengths by evaluating the ratio of the collected optical power to the incoming optical power. Finally, we examine the focusing behavior across multiple wavelengths and angles of incidence. Our work shows how nano-optics and plasmonics could contribute to this important area of CSP technology.

  10. Drying of Rosella (Hibiscus sabdariffa Flower Petals using Solar Dryer with Double Glass Cover Collector

    Directory of Open Access Journals (Sweden)

    Tjukup Marnoto

    2014-10-01

    Full Text Available Chemical ingredients in rosella petals are very beneficial for health. Rosella petals needed to be drained for storage and packing purpose. The traditional drying takes 5 days and less healthy. Solar dryer technology can speed up the drying process and protect materials from dust contamination. Solar dryer with double glass covered collector has been designed and made for drying of agricultural products such as rosella flowers. Rosella petals as much as 2300 grams with initial moisture content of 90.84 % be dried with this dryer until the moisture content of 7.67 % takes only 2 days, although the weather was less sunny . The temperature in the drying chamber was not more than 50° C, so it was good for drying groceries, not damaging chemical ingredients. The relative humidity in the space dryeris was about 40 % and it was still relative low. Drying rate and drying performance was expressed by the efficiency and Specific Moisture Evaporation Rate ( SMER were influenced by water content of the dried material and weather. Daily efficiency at the first and the second day: 14.931 % and 5.78%, while the daily SMER on the first and the second day: 0.222 and 0.0256 ( kg / kWh .

  11. Analysis of absorbed energy and efficiency of a solar flat plate collector

    Directory of Open Access Journals (Sweden)

    Anderson Miguel Lenz

    2017-07-01

    Full Text Available The highest percentage in home electricity demands in Brazil lies with the water heating systems, where the electric shower has a great contribution in consumption. The use of solar thermal panels is an alternative to minimize the strain on the electrical system by heating water. Current study evaluates a water heating system built with materials commonly used in home constructions. The tested collector is a 1 m² flat plate. Experiments were conducted at the State University of Western Paraná (UNIOESTE, campus Cascavel, Paraná State, Brazil. Temperature data were collected by PT100 sensors and solar radiation was measured with a pyranometer, coupled to a CR-1000 datalogger, with readings and collection every 5 minutes for 1 year. Data collection and analysis showed that the system presented monthly efficiency ranging between 33.7 and 53.54%, and energy absorbed between 30.79 and 75.29 kWh m-².month. Results show the system is a good option for use in residential or rural water heating due to decrease in the electric bill.

  12. System for the Automatic Estimation of the Tilt Angle of a Flat Solar Collector

    Directory of Open Access Journals (Sweden)

    Jorge Fonseca-Campos

    2017-08-01

    Full Text Available In this work, a compact system for the automatic estimation of the tilt angle at any location of the world is presented. The system components are one computer, one GPS receiver and one Python program. The tilt angle is calculated through the maximization of the flux of direct radiation incident upon a flat solar collector. An estimation of the adjustments of this angle at different time periods are obtained. This angle is calculated in steps of six minutes during a whole year. Daily, monthly, biannually and yearly averages of this value are obtained. A comparison of the energetic gain when the tilt angle changes at the different time periods is made as well. Because, the algorithm doesn’t receive as an input the solar radiation incident upon a surface at the location of the calculation, a comparison was made between the results obtained and the results reported for the monthly tilt angle of 22 different places. The root mean square error obtained with this comparison was between 1.5 and 9.5 degrees. The monthly tilt angle estimated deviated in average for less than 6.3° with respect to the values reported for the different locations. Finally, the application of a correction factor in the monthly estimated angles is proposed, which might increase the collected energy.

  13. Optimization of a Solar-Driven Trigeneration System with Nanofluid-Based Parabolic Trough Collectors

    Directory of Open Access Journals (Sweden)

    Evangelos Bellos

    2017-06-01

    Full Text Available The objective of this work was to optimize and to evaluate a solar-driven trigeneration system which operates with nanofluid-based parabolic trough collectors. The trigeneration system includes an organic Rankine cycle (ORC and an absorption heat pump operating with LiBr-H2O which is powered by the rejected heat of the ORC. Toluene, n-octane, Octamethyltrisiloxane (MDM and cyclohexane are the examined working fluids in the ORC. The use of CuO and Al2O3 nanoparticles in the Syltherm 800 (base fluid is investigated in the solar field loop. The analysis is performed with Engineering Equation Solver (EES under steady state conditions in order to give the emphasis in the exergetic optimization of the system. Except for the different working fluid investigation, the system is optimized by examining three basic operating parameters in all the cases. The pressure in the turbine inlet, the temperature in the ORC condenser and the nanofluid concentration are the optimization variables. According to the final results, the combination of toluene in the ORC with the CuO nanofluid is the optimum choice. The global maximum exergetic efficiency is 24.66% with pressure ratio is equal to 0.7605, heat rejection temperature 113.7 °C and CuO concentration 4.35%.

  14. Development and life cycle analysis of double slope active solar still with flat plate collector

    Directory of Open Access Journals (Sweden)

    A.K. Sethi

    2014-02-01

    Full Text Available Potable water is an essential ingredient of socio-economic development and economic growth. Often water sources are brackish (i.e. contain dissolved salts and/or contain harmful bacteria and therefore cannot be used for drinking. In addition, there are many coastal locations where seawater is abundant but potable water is not available. This study is focused on a development of solar still with flat plat collector for water desalination considered for small scale applications at remote locations where only saline water is available. In this paper the cost of distilled water per kg has been calculated by using the concept of life cycle cost analysis. The pay back periods for different conditions of the distribution of distilled water, namely at the cost it is produced and at the selling price on market rate have been evaluated. The cost of water per kg is minimum Rs. 0.59, when the interest rate and the lifetime of solar still are taken as 4% and 50 years respectively. The lowest payback time 1.23 years is obtained when the selling price of water Rs. 10 per kg.

  15. To develop a dynamic model of a collector loop for purpose of improved control of solar heating and cooling. Final technical report. [TRNSYS code

    Energy Technology Data Exchange (ETDEWEB)

    Herczfeld, P R; Fischl, R

    1980-01-01

    The program objectives were to (1) assess the feasibility of using the TRNSYS computer code for solar heating and cooling control studies and modify it wherever possible, and (2) develop a new dynamic model of the solar collector which reflects the performance of the collector under transient conditions. Also, the sensitivity of the performance of this model to the various system parameters such as collector time constants, flow rates, turn-on and turn-off temperature set points, solar insolation, etc., was studied. Results are presented and discussed. (WHK)

  16. A novel solar-assisted heat pump driven by photovoltaic/thermal collectors: Dynamic simulation and thermoeconomic optimization

    International Nuclear Information System (INIS)

    Calise, Francesco; Dentice d'Accadia, Massimo; Figaj, Rafal Damian; Vanoli, Laura

    2016-01-01

    This paper presents a dynamic simulation model and a thermo-economic analysis of a novel polygeneration system based on a solar-assisted heat pump and an adsorption chiller, both driven by PVT (photovoltaic/thermal) collectors. The aim of this work is to design and dynamically simulate a novel ultra-high efficient solar heating and cooling system. The overall plant layout is designed to supply electricity, space heating and cooling and domestic hot water for a small residential building. The system combines solar cooling, solar-assisted heat pump and photovoltaic/thermal collector technologies in a novel solar polygeneration system. In fact, the polygeneration system is based on a PVT solar field, coupled with a water-to-water electric heat pump or to an adsorption chiller. PVT collectors simultaneously produce electricity and thermal energy. During the winter, hot water produced by PVT collectors primarily supplies the evaporator of the heat pump, whereas in summer, solar energy supplies an adsorption chiller providing the required space cooling. All year long, solar thermal energy in excess is converted into DHW (domestic hot water). The system model was developed in TRNSYS environment. 1-year dynamic simulations are performed for different case studies in various weather conditions. The results are analysed on different time bases presenting energetic, environmental and economic performance data. Finally, a sensitivity analysis and a thermoeconomic optimization were performed, in order to determine the set of system design/control parameters that minimize the simple pay-back period. The results showed a total energy efficiency of the PVT of 49%, a heat pump yearly coefficient of performance for heating mode above 4 and a coefficient of performance of the adsorption chiller of 0.55. Finally, it is also concluded that system performance is highly sensitive to the PVT field area. The system is profitable when a capital investment subsidy of 50% is considered

  17. Evaluation of high performance evacuated tubular collectors in a residential heating and cooling system: Colorado State University Solar House I. Report for October 1, 1976--September 30, 1977

    Energy Technology Data Exchange (ETDEWEB)

    Duff, W.S.; Conway, T.M.; Loef, G.O.G.; Meredith, D.B.; Pratt, R.B.

    1978-03-01

    CSU Solar House I is configured with a prototype Corning evacuated tubular collector and a new Arkla lithium bromide water chiller designed for solar operation. Data have been collected for this configuration since January 1977. Prior to that time and since mid-1974, Solar House I has operated with a flat-plate collector and a previous Arkla LiBr air conditioner modified to operate in the lower solar temperature ranges. Project objectives were to develop an operating and control system for the new configuration and to compare the performance of the new residential solar heating, cooling, and hot water system with performance of the previous system. Many problems were encountered in the evolution of the operating and control systems due to the different operating characteristics of evacuated tubular collectors, such as their rapid thermal response and the possibility of much higher temperatures as compared to a flat-plate collector.

  18. Genesis Solar Wind Collector Cleaning Assessment: Update on 60336 Sample Case Study

    Science.gov (United States)

    Goreva, Y. S.; Allums, K. K.; Gonzalez, C. P.; Jurewicz, A. J.; Burnett, D. S.; Allton, J. H.; Kuhlman, K. R.; Woolum, D.

    2015-01-01

    To maximize the scientific return of Genesis Solar Wind return mission it is necessary to characterize and remove a crash-derived particle and thin film surface contamination. A small subset of Genesis mission collector fragments are being subjected to extensive study via various techniques. Here we present an update on the sample 60336, a Czochralski silicon (Si-CZ) based wafer from the bulk array (B/C). This sample has undergone multiple cleaning steps (see the table below): UPW spin wash, aggressive chemical cleanings (including aqua regia, hot xylene and RCA1), as well as optical and chemical (EDS, ToF-SIMS) imaging. Contamination appeared on the surface of 60336 after the initial 2007 UPW cleaning. Aqua regia and hot xylene treatment (8/13/2013) did little to remove contaminants. The sample was UPW cleaned for the third time and imaged (9/16/13). The UPW removed the dark stains that were visible on the sample. However, some features, like "the Flounder" (a large, 100 micron feature in Fig. 1b) appeared largely intact, resisting all previous cleaning efforts. These features were likely from mobilized adhesive, derived from the Post-It notes used to stabilize samples for transport from Utah after the hard landing. To remove this contamination, an RCA step 1 organic cleaning (RCA1) was employed. Although we are still uncertain on the nature of the Flounder and why it is resistant to UPW and aqua regia/hot xylene treatment, we have found RCA1 to be suitable for its removal. It is likely that the glue from sticky pads used during collector recovery may have been a source for resistant organic contamination [9]; however [8] shows that UPW reaction with crash-derived organic contamination does not make particle removal more difficult.

  19. Renewable Electricity Generation via Solar-Powered Methanol Reforming: Hybrid Proton Exchange Membrane Fuel Cell Systems Based on Novel Non-Concentrating, Intermediate-Temperature Solar Collectors

    Science.gov (United States)

    Real, Daniel J.

    Tremendous research efforts have been conducted studying the capturing and conversion of solar energy. Solar thermal power systems offer a compelling opportunity for renewable energy utilization with high efficiencies and excellent cost-effectiveness. The goal of this work was to design a non-concentrating collector capable of reaching temperatures above 250 °C, use this collector to power methanol steam reforming, and operate a proton exchange membrane (PEM) fuel cell using the generated hydrogen. The study presents the construction and characterization of a non-concentrating, intermediate-temperature, fin-in-tube evacuated solar collector, made of copper and capable of reaching stagnation temperatures of 268.5 °C at 1000 W/m2 irradiance. The collector was used to power methanol steam reforming, including the initial heating and vaporization of liquid reactants and the final heating of the gaseous reactants. A preferential oxidation (PROX) catalyst was used to remove CO from simulated reformate gas, and this product gas was used to operate a PEM fuel cell. The results show 1) that the outlet temperature is not limited by heat transfer from the absorber coating to the heat transfer fluid, but by the amount of solar energy absorbed. This implicates a constant heat flux description of the heat transfer process and allows for the usage of materials with lower thermal conductivity than copper. 2) It is possible to operate a PEM fuel cell from reformate gas if a PROX catalyst is used to remove CO from the gas. 3) The performance of the fuel cell is only slightly decreased (~4%) by CO2 dilution present in the reformate and PROX gas. These results provide a foundation for the first renewable electricity generation via solar-powered methanol reforming through a hybrid PEM fuel cell system based on novel non-concentrating, intermediate-temperature solar collectors.

  20. Resource indexes of flat solar water-heating collectors in hot-water-supply systems: Part 3. Source data for calculations that depend on the weight, size, and heat engineering characteristics of the collector and the optic properties of the translucent collector coating

    International Nuclear Information System (INIS)

    Avezova, N. R.; Suleymanov, Sh. I.; Avezov, R. R.; Vakhidov, A.

    2013-01-01

    Source data are given for calculating resource indexes of flat solar water-heating collectors (FSWHCs) in hot-water-supply systems (HWSSs) that depend on the weight, size, and heat engineering characteristics of the collectors of the type considered and on the optic properties of their translucent coating. (authors)

  1. Development and evaluation of a ceiling ventilation system enhanced by solar photovoltaic thermal collectors and phase change materials

    International Nuclear Information System (INIS)

    Lin, Wenye; Ma, Zhenjun; Sohel, M. Imroz; Cooper, Paul

    2014-01-01

    Highlights: • A novel ceiling ventilation system enhanced by PVT and PCMs was proposed. • PCM was used to increase the local thermal mass and to serve as a storage unit. • The proposed system can enhance indoor thermal comfort in winter and summer. - Abstract: This paper presents the development and performance evaluation of a novel ceiling ventilation system integrated with solar photovoltaic thermal (PVT) collectors and phase change materials (PCMs). The PVT collectors are used to generate electricity and provide low grade heating and cooling energy for buildings by using winter daytime solar radiation and summer night-time sky radiative cooling, respectively. The PCM is integrated into the building ceiling as a part of the ceiling insulation and at the same time, as a centralized thermal energy storage to temporally store low grade energy collected from the PVT collectors. The performance of the proposed system was numerically evaluated based on a Solar Decathlon house using TRNSYS. The results showed that, in winter conditions, the proposed PVT–PCM integrated ventilation system can significantly improve the indoor thermal comfort of passive buildings without using air-conditioning systems with a maximum air temperature rise of 23.1 °C from the PVT collectors. Compared with the system using PCM but without using PVT collectors, the coefficient of thermal comfort enhancement in the kitchen, dining room and living room of the case building studied using the proposed system improved from almost zero to 0.9823 while the coefficient of thermal comfort enhancement in the study room improved from 0.0060 to 0.9921. In summer conditions, the proposed system can also enhance indoor thermal comfort through night-time sky radiative cooling

  2. The sizes of Flat Plate and Evacuated Tube Collectors with Heat Pipe area as a function of the share of solar system in the heat demand

    Directory of Open Access Journals (Sweden)

    Olek Małgorzata

    2016-01-01

    Full Text Available The popularity of solar collectors in Poland is still increasing. The correct location of the collectors and a relatively high density of solar radiation allow delivering heat even in spite of relatively low ambient temperature. Moreover, solar systems used for heating domestic heat water (DHW in summer allow nearly complete elimination of conventional energy sources (e.g. gas, coal. That is why more and more house owners in Poland decide to install solar system installations. In Poland the most common types of solar collectors are flat plate collectors (FPC and evacuated tube collectors with heat pipe (ETCHP; both were selected for the analysis. The heat demand related to the preparation of hot water, connected with the size of solar collectors’ area, has been determined. The analysis includes FPC and ETCHP and heat demand of less than 10 000 kWh/year. Simulations were performed with the Matlab software and using data from a typical meteorological year (TMY. In addition, a 126–year period of measurements of insolation for Krakow has been taken into account. The HDKR model (Hay, Davis, Klucher, Reindl was used for the calculation of solar radiation on the absorber surface. The monthly medium temperature of the absorber depends on the amount of solar system heat and on the heat demand. All the previously mentioned data were used to determine solar efficiency. Due to the fact that solar efficiency and solar system heat are connected, the calculations were made with the use of an iterative method. Additionally, the upper limit for monthly useful solar system heat is resulted from the heat demand and thus the authors prepared a model of statistical solar system heat deviations based on the Monte Carlo method. It has been found that an increase in the useful solar system heat in reference to the heat demand is associated with more than proportional increase in the sizes of the analyzed surfaces of solar collector types.

  3. Mathematical model for thermal solar collectors by using magnetohydrodynamic Maxwell nanofluid with slip conditions, thermal radiation and variable thermal conductivity

    Directory of Open Access Journals (Sweden)

    Asif Mahmood

    Full Text Available Solar energy is the cleanest, renewable and most abundant source of energy available on earth. The main use of solar energy is to heat and cool buildings, heat water and to generate electricity. There are two types of solar energy collection system, the photovoltaic systems and the solar thermal collectors. The efficiency of any solar thermal system depend on the thermophysical properties of the operating fluids and the geometry/length of the system in which fluid is flowing. In the present research a simplified mathematical model for the solar thermal collectors is considered in the form of non-uniform unsteady stretching surface. The flow is induced by a non-uniform stretching of the porous sheet and the uniform magnetic field is applied in the transverse direction to the flow. The non-Newtonian Maxwell fluid model is utilized for the working fluid along with slip boundary conditions. Moreover the high temperature effect of thermal radiation and temperature dependent thermal conductivity are also included in the present model. The mathematical formulation is carried out through a boundary layer approach and the numerical computations are carried out for cu-water and TiO2-water nanofluids. Results are presented for the velocity and temperature profiles as well as the skin friction coefficient and Nusselt number and the discussion is concluded on the effect of various governing parameters on the motion, temperature variation, velocity gradient and the rate of heat transfer at the boundary. Keywords: Solar energy, Thermal collectors, Maxwell-nanofluid, Thermal radiation, Partial slip, Variable thermal conductivity

  4. Solar cycle modulation of ENSO variability

    Science.gov (United States)

    Kodera, Kunihiko; Thiéblemont, Rémi

    2016-04-01

    Inspired by the work of Labitzke and van Loon on solar/QBO modulation in the stratosphere, Barnett (1989) conducted an investigation on the relationship between the the biannual component of the sea surface temperature (SST) in the equatorial eastern Pacific and the solar activity. He found that the amplitude of biannual component of the SST (BO) is modulated by the 11-year solar cycle: the amplitude of the BO is large during a period of low solar activity, but small during high solar activity. More than 25-years or two solar cycle has passed since his finding, but the relationship still holds. In order to get an insight into the mechanism of the solar modulation of the El Niño Southern Oscillation (ENSO), here we have revisited this problem. Solar cycle modulation of the BO in the tropical SST is discernible since the end of the 19th centuries, but the amplitude modulation is particularly clear after 1960's. The composite analysis of the SST based on the amplitude of the BO during 1958-2012, indicates that the amplitude of BO is larger when the equatorial Pacific temperature anomalies are high in the central Pacific, but low in the eastern Pacific. Central Pacific anomalies extend to the northern hemisphere, while those in the central Pacific spread toward the southern hemisphere. In short, this anomalous SST pattern is similar to the El Niño modoki. In this connection, it should be noted that the solar signal in the tropical SST also exhibits a similar pattern. This suggests that the modulation of the ENSO variability by the solar cycle originates through a modulation of the El Niño Modoki rather than the canonical El Nino.

  5. Mathematical model for thermal solar collectors by using magnetohydrodynamic Maxwell nanofluid with slip conditions, thermal radiation and variable thermal conductivity

    Science.gov (United States)

    Mahmood, Asif; Aziz, Asim; Jamshed, Wasim; Hussain, Sajid

    Solar energy is the cleanest, renewable and most abundant source of energy available on earth. The main use of solar energy is to heat and cool buildings, heat water and to generate electricity. There are two types of solar energy collection system, the photovoltaic systems and the solar thermal collectors. The efficiency of any solar thermal system depend on the thermophysical properties of the operating fluids and the geometry/length of the system in which fluid is flowing. In the present research a simplified mathematical model for the solar thermal collectors is considered in the form of non-uniform unsteady stretching surface. The flow is induced by a non-uniform stretching of the porous sheet and the uniform magnetic field is applied in the transverse direction to the flow. The non-Newtonian Maxwell fluid model is utilized for the working fluid along with slip boundary conditions. Moreover the high temperature effect of thermal radiation and temperature dependent thermal conductivity are also included in the present model. The mathematical formulation is carried out through a boundary layer approach and the numerical computations are carried out for cu-water and TiO2 -water nanofluids. Results are presented for the velocity and temperature profiles as well as the skin friction coefficient and Nusselt number and the discussion is concluded on the effect of various governing parameters on the motion, temperature variation, velocity gradient and the rate of heat transfer at the boundary.

  6. Modelling and analysis of a heating system for industrial application, using flat-plate solar-collectors with single and double cover glasses

    International Nuclear Information System (INIS)

    Maraslis, A.A.

    1987-01-01

    A calculational methodology for dimensioning a flat-plate solar-collector arrangement, which fulfils the energy requirement of a heat transfer system in one of the steps of the uranium recovery process, from the uranium-phosphorus ore at Itataia, Ceara, in Brazil. The PROSOL-1 and PROSOL-2 computer codes for determining the total area required by collector arrangement-with single and double cover glasses, respectively- taking into account the system design and meteorological conditions of the regions, were used. These codes optimize the series/parallel arranges of collectors in the whole complex and, determine the water flow in each system and the average efficiency of the collector arrangement. The technical and economical feasibility for both collector arrangement with single and double cover glasses, were verified. It was concluded that, the last one is more advantageous, allowing a reduction of 30% in the total collector area. (M.C.K.) [pt

  7. Solar energy collector including a weightless balloon with sun tracking means

    Science.gov (United States)

    Hall, Frederick F.

    1978-01-01

    A solar energy collector having a weightless balloon, the balloon including a transparent polyvinylfluoride hemisphere reinforced with a mesh of ropes secured to its outside surface, and a laminated reflector hemisphere, the inner layer being clear and aluminized on its outside surface and the outer layer being opaque, the balloon being inflated with lighter-than-air gas. A heat collection probe extends into the balloon along the focus of reflection of the reflective hemisphere for conducting coolant into and out of the balloon. The probe is mounted on apparatus for keeping the probe aligned with the sun's path, the apparatus being founded in the earth for withstanding wind pressure on the balloon. The balloon is lashed to the probe by ropes adhered to the outer surface of the balloon for withstanding wind pressures of 100 miles per hour. Preferably, the coolant is liquid sodium-potassium eutectic alloy which will not normally freeze at night in the temperate zones, and when heated to 4,000.degree. R exerts a pressure of only a few atmospheres.

  8. Design of a single flat null-screen for testing a parabolic trough solar collector

    Science.gov (United States)

    Moreno-Oliva, Víctor Iván; Campos-García, Manuel; Román-Hernández, Edwin; Santiago-Alvarado, Agustín

    2014-11-01

    We present a null-screen design for testing the shape quality of the reflecting surface of a parabolic trough solar collector (PTSC). This technique is inexpensive, the whole surface is tested at once, and it is easy to implement. For this, we propose the design of a flat null-screen perpendicular to the optical axis of the PTSC in such a way that it allows testing of the full aperture; we compute the caustic associated with the reflected light rays on the desired surface and analyze the parameters that determine the null-screen dimensions. Additionally, we perform a numerical simulation to analyze the accuracy of the method by introducing random displacement errors into the measured data. Accuracies >0.35 mrad were found to evaluate the quality of surfaces with this method. The errors in the determination of the coordinates of the centroids of the reflected images must be measured with an accuracy >0.5 pixels, and the errors in the coordinates of the spots of the null-screen must be <0.5 mm.

  9. Validation of a simple dynamic thermal performance characterization model based on the piston flow concept for flat-plate solar collectors

    DEFF Research Database (Denmark)

    Deng, Jie; Yang, Ming; Ma, Rongjiang

    2016-01-01

    A simple dynamic characterization model of flat-plate solar collectors based on the piston flow concept is used both to identify the collector characteristic parameters and to predict the dynamic thermal performance. The heat transport time originally defined as (1 − e−1)−1τC by Amrizal et al....... (2012) for the model turns out to be the collector static response time constant τC by analytical derivation. The nonlinear least squares method is applied to determine the characteristic parameters of a flat-plate solar air collector previously tested by the authors. Then the obtained parameters...... dynamic model based on the first-order difference method is compared to that of the numerical solution of the collector ordinary differential equation (ODE) model using the fourth-order Runge-Kutta method. The improved thermal inertia model (TIM) on the basis of closed-form solution presented by Deng et...

  10. Preliminary design review package on air flat plate collector for solar heating and cooling system

    Science.gov (United States)

    1977-01-01

    Guidelines to be used in the development and fabrication of a prototype air flat plate collector subsystem containing 320 square feet (10-4 ft x 8 ft panels) of collector area are presented. Topics discussed include: (1) verification plan; (2) thermal analysis; (3) safety hazard analysis; (4) drawing list; (5) special handling, installation and maintenance tools; (6) structural analysis; and (7) selected drawings.

  11. Discrimination and quantification of contamination and implanted solar wind in Genesis collector shards using grazing incidence synchrotron x-ray techniques: Initial results

    International Nuclear Information System (INIS)

    Kitts, K.; Sutton, S.; Eng, P.; Ghose, S.; Burnett, D.

    2006-01-01

    Grazing incidence X-ray fluorescence is a non-destructive technique that can differentiate the embedded solar wind component from surface contamination and collector background in the Genesis shards. Initial solar Fe abundance in D30554 is 8 x 10 12 /cm 2 . Accurate knowledge of the composition of the Sun provides a baseline, which allows an understanding of how the solar system has evolved over time and how solar processes and solar wind mechanics behave. Unfortunately, the errors in photospheric abundances are too large for many planetary science problems and this hampers our understanding of these different processes. Analyses of solar wind implanted in meteorites or lunar soils have provided more precise data but alteration processes on these bodies may complicate such information. In response to this need for pristine solar wind samples, NASA developed and launched the Genesis Probe. Unfortunately, the probe smashed into the Utah desert shattering the 300 collector plates into 15,000+ pieces all of which are now coated in a both a fine terrestrial dust and Si and Ge powder from the disrupted collectors themselves. The solar wind penetration depth is 100-200 nm and the superposed contamination layers are typically 40-50 nm. Stringent cleaning regimes have the potential of removing the solar wind itself. The best solution is to have sufficient spatial resolution to separately analyze the surface contamination and penetrated solar wind. To that end, three Genesis collector array shards and their appropriate flight spares were characterized via grazing incidence x-ray fluorescence and x-ray reflectivity. The goals were (1) to evaluate the various cleaning methods used to eliminate contamination, (2) to identify the collector substrates most suited for this technique, (3) to determine whether the solar wind signature could be deconvolved from the collector background signature, and (4) to measure the relative abundances of Ca to Ge in the embedded solar wind.

  12. Analysis of feasibility from a amianthus cement tile collector of solar energy; Analise de viabilidade de uma telha coletora de energia solar de cimento amianto

    Energy Technology Data Exchange (ETDEWEB)

    Alencar, Francisco de [UNESP, Bauru, SP (Brazil). Faculdade de Arquitetura, Artes e Comunicacao. Dept. de Desenho Industrial; Saglietti, Jose Roberto Correa [UNESP, Botucatu, SP (Brazil). Inst. de Biociencias. Dept. de Fisica e Biofisica

    1999-06-01

    This work aimed to develop the idea of joining in a single product a residential roof tile capable of acting simultaneously as a sun radiation collector. In order to do this, a study was accomplished on how the integration of a solar collector to the architectural project of a house occurs, taking into account the various aspects of installation and design. A prototype which uses one of the most common construction materials was projected, built and evaluated for testing the hypothesis. This prototype uses amianthus cement tile, together with copper sheets and pipes, aluminum sheets, glasses and other finishing. The evaluation consisted basically of behaviour analysis of the components when submitted to high work temperatures and measurements taken allowing a first calculation of the prototype efficiency. As a comparison parameter, a plane solar collector sold throughout the country was used. It has a qualifying stamp emitted by the Instituto Nacional de Metrologia, certifying as a high performance equipment. Some experiment results showed that the prototype presented promising efficiency for the project stage, allowing the foreseeing that, with the implementation of the improvements, a compatible efficiency can be reached at lower prices compared to the standard collector. In order to analyse the energetic efficiency, the forced circulation regimen of the working fluid was adopted, with controlled outlet; calculations were taken each five minutes, in the period between 10:00 am. and 2:00 p m, in good insolation days. The input and output temperatures of the fluid in the collector and in the prototypes were measured by means of thermocouples connected to a data acquisition board from a computer exclusively dedicated to this finality. The solar radiation register was obtained by a Kipp-Zonen pyrano meter and the data were stored into a 'data logger' each five minutes, thus establishing a data base, which latter allowed the development of further work

  13. Planar solar concentrator featuring alignment-free total-internal-reflection collectors and an innovative compound tracker.

    Science.gov (United States)

    Teng, Tun-Chien; Lai, Wei-Che

    2014-12-15

    This study proposed a planar solar concentrator featuring alignment-free total-internal-reflection (TIR) collectors and an innovative compound tracker. The compound tracker, combining a mechanical single-axis tracker and scrollable prism sheets, can achieve a performance on a par with dual-axis tracking while reducing the cost of the tracking system and increasing its robustness. The alignment-free TIR collectors are assembled on the waveguide without requiring alignment, so the planar concentrator is relatively easily manufactured and markedly increases the feasibility for use in large concentrators. Further, the identical TIR collector is applicable to various-sized waveguide slab without requiring modification, which facilitates flexibility regarding the size of the waveguide slab. In the simulation model, the thickness of the slab was 2 mm, and its maximal length reached 6 m. With an average angular tolerance of ±0.6°, and after considering both the Fresnel loss and the angular spread of the sun, the simulation indicates that the waveguide concentrator of a 1000-mm length provides the optical efficiencies of 62-77% at the irradiance concentrations of 387-688, and the one of a 2000-mm length provides the optical efficiencies of 52-64.5% at the irradiance concentrations of 645-1148. Alternatively, if a 100-mm horizontally staggered waveguide slab is collocated with the alignment-free TIR collectors, the optical efficiency would be greatly improved up to 91.5% at an irradiance concentration of 1098 (C(geo) = 1200X).

  14. SIMULATION OF SOLAR LITHIUM BROMIDE–WATER ABSORPTION COOLING SYSTEM WITH DOUBLE GLAZED FLAT PLATE COLLECTOR FOR ADRAR

    Directory of Open Access Journals (Sweden)

    ML CHOUGUI

    2014-12-01

    Full Text Available Adrar is a city in the Sahara desert, in southern Algeria known for its hot and dry climate, where a huge amount of energy is used for air conditioning. The aim of this research is to simulate a single effect lithium bromide–water absorption chiller coupled to a double-glazed flat plate collector to supply the cooling loads for a house of 200m2 in Adrar. The thermal energy is stored in an insulated thermal storage tank. The system was designed to cover a cooling load of 10.39KW for design day of July. Thermodynamic model was established to simulate the absorption cycle. The results have shown that the collector mass flow rate has a negligible effect on the minimum required collector area, but it has a significant effect on the optimum capacity of the storage tank. The minimum required collector area was about 65.3 m2, which could supply the cooling loads for the sunshine hours of the design day for July. The operation of the system has also been considered after sunset by saving solar energy.

  15. Numerical and Experimental Study on Energy Performance of Photovoltaic-Heat Pipe Solar Collector in Northern China

    Directory of Open Access Journals (Sweden)

    Hongbing Chen

    2015-01-01

    Full Text Available Several studies have found that the decrease of photovoltaic (PV cell temperature would increase the solar-to-electricity conversion efficiency. Water type PV/thermal (PV/T system was a good choice but it could become freezing in cold areas of Northern China. This paper proposed a simple combination of common-used PV panel and heat pipe, called PV-heat pipe (PV-HP solar collector, for both electrical and thermal energy generation. A simplified one-dimensional steady state model was developed to study the electrical and thermal performance of the PV-HP solar collector under different solar radiations, water flow rates, and water temperatures at the inlet of manifold. A testing rig was conducted to verify the model and the testing data matched very well with the simulation values. The results indicated that the thermal efficiency could be minus in the afternoon. The thermal and electrical efficiencies decreased linearly as the inlet water temperature and water flow rate increased. The thermal efficiency increased while the electrical efficiency decreased linearly as the solar radiation increased.

  16. Source term boundary adaptive estimation in a first-order 1D hyperbolic PDE: Application to a one loop solar collector through

    KAUST Repository

    Mechhoud, Sarra

    2016-08-04

    In this paper, boundary adaptive estimation of solar radiation in a solar collector plant is investigated. The solar collector is described by a 1D first-order hyperbolic partial differential equation where the solar radiation models the source term and only boundary measurements are available. Using boundary injection, the estimator is developed in the Lyapunov approach and consists of a combination of a state observer and a parameter adaptation law which guarantee the asymptotic convergence of the state and parameter estimation errors. Simulation results are provided to illustrate the performance of the proposed identifier.

  17. Assembly jig assures reliable solar cell modules

    Science.gov (United States)

    Ofarrell, H. O.

    1966-01-01

    Assembly jig holds the components for a solar cell module in place as the assembly is soldered and bonded by the even heat of an oven. The jig is designed to the configuration of the planned module. It eliminates uneven thermal conditions caused by hand soldering methods.

  18. Pulsed depressed collector

    Science.gov (United States)

    Kemp, Mark A

    2015-11-03

    A high power RF device has an electron beam cavity, a modulator, and a circuit for feed-forward energy recovery from a multi-stage depressed collector to the modulator. The electron beam cavity include a cathode, an anode, and the multi-stage depressed collector, and the modulator is configured to provide pulses to the cathode. Voltages of the electrode stages of the multi-stage depressed collector are allowed to float as determined by fixed impedances seen by the electrode stages. The energy recovery circuit includes a storage capacitor that dynamically biases potentials of the electrode stages of the multi-stage depressed collector and provides recovered energy from the electrode stages of the multi-stage depressed collector to the modulator. The circuit may also include a step-down transformer, where the electrode stages of the multi-stage depressed collector are electrically connected to separate taps on the step-down transformer.

  19. Assessment of the Use of Venetian Blinds as Solar Thermal Collectors in Double Skin Facades in Mediterranean Climates

    Directory of Open Access Journals (Sweden)

    Abel Velasco

    2017-11-01

    Full Text Available The global trend on energy integration and building efficiency is making both researchers and building developers look for technical solutions to use facade surfaces for energy harvesting. In this work, the assessment of the thermal performance of a double-skin facade (DSF with a venetian blind-type of structure used as a solar thermal collector by means of computational fluid dynamics (CFD is presented. A Venetian blind collector would allow for heat rejection/energy harvesting and exterior views simultaneously and can be easily integrated into the DSF aesthetical design. For the purposes of this study, the modeled facades (south, west, and east-oriented were set to be located in Barcelona (Spain, where large solar gains are a constant condition throughout the year, and such large semi-transparent envelopes lead to interior over-heating in buildings, even during the winter. For the studied facades, both the reductions in radiative heat gains entering the building and the heat recovery in the Venetian blind collector were evaluated for a yearlong operation.

  20. Standard Practice for Generating All-Day Thermal Performance Data for Solar Collectors

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1987-01-01

    1.1 This practice covers a means of generating all-day thermal performance data for flat-plate collectors, concentrating collectors, and tracking collectors. 1.2 The values stated in SI units are to be regarded as the standard. The values given in the parentheses are for information only. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  1. Mount for continuously orienting a collector dish in a system adapted to perform both diurnal and seasonal solar tracking

    Science.gov (United States)

    Brantley, L. W., Jr.; Lawson, B. D. (Inventor)

    1977-01-01

    A collector dish is continuously oriented toward the sun in a system adapted to perform both diurnal and seasonal solar tracking. The mount is characterized by a rigid, angulated axle having a linear midportion supporting a collector dish, and oppositely extended end portions normally related to the midportion of the axle and received in spaced journals. The longitudinal axis of symmetry for the midportion of the axle is coincident with a seasonal axis while the axes of the journals are coincident with a diurnal axis paralleling the earth's polar axis. Drive means are provided for periodically displacing the axle about the diurnal axis at a substantially constant rate, while other drive means are provided for periodically indexing the dish through 1 deg about the seasonal axis whereby the position of the dish relative to the axle is varied for accommodating seasonal tracking as changes in the angle of inclination of the polar axis occurs.

  2. Investigation of methods to transfer heat from solar liquid-heating collectors to heat storage tanks

    Energy Technology Data Exchange (ETDEWEB)

    de Winter, F.

    1976-01-01

    A number of possible solutions to the problems of corrosion and freezing in flat-plate collectors are listed and discussed briefly. Specific considerations involved in the choice and definition of these solutions are discussed in greater detail. (MHR)

  3. Comparative simulation analyses on dynamic performances of photovoltaic–thermal solar collectors with different configurations

    International Nuclear Information System (INIS)

    Shan, Feng; Tang, Fang; Cao, Lei; Fang, Guiyin

    2014-01-01

    Highlights: • Recent developments of the PV/T systems were summarized. • The dynamic model of the PV/T system with different configurations was developed. • The performance parameters were derived to conduct comparative analyses. • The performances of the PV/T system were evaluated and analyzed. • The PV/T configurations have influences on the performances of the PV/T system. - Abstract: The electrical efficiency of photovoltaic (PV) module can be increased by reducing the operating temperature of PV module. The hybrid photovoltaic/thermal (PV/T) solar system consists of conventional PV module and attached heat transfer pipe with internal working fluid flowing to extract heat energy from PV module. This article presents a brief review on the latest researches and applications of the PV/T systems. Afterwards, based on energy-balance equations, mathematical models for several PV/T systems with different configurations are developed. Analytical expressions for both the electrical and thermal performance parameters are derived as functions of climatic and design parameters to conduct comparative analyses. The calculation results indicate that the changes in the PV/T configurations have influences on electrical and thermal performances of the PV/T system. Further suggestions on configurations optimization for practical applications are propounded

  4. Nice module. Apollon Solar present their new line of solar modules; Nettes Modul. Apollon Solar stellt Linie fuer neuartige Modultechnologie vor

    Energy Technology Data Exchange (ETDEWEB)

    Podewils, C.

    2008-06-15

    Solar modules, TGV engines and perfume Zerstaeuber seem to have nothing in common. The new solar module developed by French producer Apollon Solar makes use of both technologies in the construction process. The contribution presents the 'Nice' module which has many new features. (orig.)

  5. Mars Atmosphere and Regolith COllector/PrOcessor for Lander Ops (MARCO POLO) Atmospheric Processing Module

    Data.gov (United States)

    National Aeronautics and Space Administration — The multi-NASA center Mars Atmosphere and Regolith COllector/PrOcessor for Lander Operations (MARCO POLO) project was established to build and demonstrate a...

  6. Long-term ageing tests on glazing materials for solar collectors; Langzeit-Alterungsuntersuchung an Abdeckungsmaterialien fuer thermische Sonnenkollektoren

    Energy Technology Data Exchange (ETDEWEB)

    Ruesch, F.; Brunold, S.; Haeuselmann, T.; Frank, E.; Frei, U.

    2008-02-15

    This report made by the Swiss Institute for Solar Technology at the University of Applied Sciences in Rapperswil, Switzerland, for Swiss Federal Office of Energy (SFOE) takes a look at the results of a project that investigated the long-term behaviour of glazing materials for solar collectors. The locations tested and their associated meteorological data are presented and the tests made concerning the optical characteristics of several different types of glazing are discussed. Soiling and degradation are also looked at. An overview of the solar transmission of the various materials is presented. Details on the various materials such as glass, polymethyl metacrylate (PMMA), polycarbonate (PC), fluorised plastics, unsaturated polyester (UP), polyvinyl chloride (PVC) and polyethylene terephthalate (PET) are presented.

  7. An economic optimization of evaporator and air collector area in a solar assisted heat pump drying system

    International Nuclear Information System (INIS)

    Rahman, S.M.A.; Saidur, R.; Hawlader, M.N.A.

    2013-01-01

    Highlights: • The optimum combination will provide around 89% of the total load. • The system has a savings during the life cycle with least payback period of 4.37 year. • The optimal system is insensitive to the variation in fuel inflation and discount rate. - Abstract: This paper presents an economic optimization of evaporator and air collector area of a solar assisted heat pump drying system. Economic viability of solar heating systems is usually made by comparing the cost flows recurring throughout the lifetime of the solar and conventional alternative systems. Therefore, identification of optimum variables by using a simulation program and an economic analysis based on payback period of the system are presented in this paper. FORTRAN language is used to run the simulation. Effect of load and different economic variables on payback period is also investigated. Economic analysis reveals that system has sufficient amount of savings during the life cycle with a minimum payback period of about 4 years

  8. Design, construction and evaluation of solar flat-plate collector simulator based on the thermohydraulic coefficient

    Directory of Open Access Journals (Sweden)

    H Rahmati Aidinlou

    2017-05-01

    Full Text Available Introduction Increasing the area of absorber plate between the flowed air through the duct can be accomplished by corrugating the absorber plate or by using the artificial roughness underside of the absorber plate as the commercial methods for enhancing the thermohydraulic performance of the flat plate solar air heaters. Evaluation of this requires the construction of separated solar air heater which is costly and time consuming. The constructed solar flat-plate collector simulator can be a sufficient solution for obtaining the heat transfer and thermodynamic parameters for evaluating the absorber plate. The inclined broken roughness was chosen as the optimum roughness which is surrounded by three aluminum smooth walls. Materials and Methods The duct for both smooth and roughened plate have been constructed based on the ASHRAE 93-2010 standard. In order to achieve a fully thermal and hydraulic developed flow, the plenum is constructed. The centrifugal fan is considered by applying the required air volume at the pressure drop obtained by the duct, plenum and the orifice meter. The TSI velocity-meter 8355 is used to measure the velocity of air crossing through the pipe connected to the centrifugal fan. The micro manometer Kimo CPE310-s with the resolution of 0.1 Pa is used to measure the pressure drop across the test section of the smooth and roughened duct. The LM35 sensors are used to measure the absorber plate and air temperature through the test section. Obtained parameters are used to calculate the Nusselt number and friction factor across the test section for smooth and roughened absorber plate. The Nusselt number and friction factor parameters which is obtained for smooth absorber plate based on experimental set-up, is compared with Dittus-Bolter and Blasius equations, respectively, for validating the simulator. By calculating the Nusselt number and friction factor, Stanton number is obtained based on the equation (6, and thermohydraulic

  9. Aging and characterization of PVC compound used as flat-panel of a low cost solar collector; Envelhecimento e caracterizacao de compostos de PVC usado em placas de coletores solares de baixo custo

    Energy Technology Data Exchange (ETDEWEB)

    Prado, Bruna R.; Pinto, Tatiana T.; Bartoli, Julio R. [Depto. de Tecnologia de Polimeros, Faculdade de Engenharia Quimica/Universidade Estadual de Campinas. FEQ/UNICAMP, SP (Brazil)], e-mail: bartoli@feq.unicamp.br; Fernandes, Elizabeth G. [Tezca P and D Celulas Solares (Brazil)

    2011-07-01

    Regardless the excellent amount of solar irradiation in Brazil, the development and production of solar water heating systems did not reach the low-income families yet. The relatively high cost of conventional solar water heaters is still the main reason to prevent it. The development of a low cost solar water heater (around US$ 200), easy technology, was the scope of previous work. All-plastic solar collector prototypes were developed using unplasticized Poly (vinyl chloride) ceiling panels and tubes, commodities from building engineering. Nevertheless, the main thermal and photo degradation mechanisms for PVC are well known; the unusual application of PVC as solar collector materials should need a specific investigation on environmental aging. This work presents a study on outdoor aging and characterization of PVC flat-plate absorber of solar collectors after 5 years on use. (author)

  10. Collecting Solar Energy. Solar Energy Education Project.

    Science.gov (United States)

    O'Brien, Alexander

    This solar energy learning module for use with junior high school students offers a list of activities, a pre-post test, job titles, basic solar energy vocabulary, and diagrams of solar energy collectors and installations. The purpose is to familiarize students with applications of solar energy and titles of jobs where this knowledge could be…

  11. ISS-based Development of Elements and Operations for Robotic Assembly of A Space Solar Power Collector

    Science.gov (United States)

    Valinia, Azita; Moe, Rud; Seery, Bernard D.; Mankins, John C.

    2013-01-01

    We present a concept for an ISS-based optical system assembly demonstration designed to advance technologies related to future large in-space optical facilities deployment, including space solar power collectors and large-aperture astronomy telescopes. The large solar power collector problem is not unlike the large astronomical telescope problem, but at least conceptually it should be easier in principle, given the tolerances involved. We strive in this application to leverage heavily the work done on the NASA Optical Testbed Integration on ISS Experiment (OpTIIX) effort to erect a 1.5 m imaging telescope on the International Space Station (ISS). Specifically, we examine a robotic assembly sequence for constructing a large (meter diameter) slightly aspheric or spherical primary reflector, comprised of hexagonal mirror segments affixed to a lightweight rigidizing backplane structure. This approach, together with a structured robot assembler, will be shown to be scalable to the area and areal densities required for large-scale solar concentrator arrays.

  12. Obliquity Modulation of the Incoming Solar Radiation

    Science.gov (United States)

    Liu, Han-Shou; Smith, David E. (Technical Monitor)

    2001-01-01

    Based on a basic principle of orbital resonance, we have identified a huge deficit of solar radiation induced by the combined amplitude and frequency modulation of the Earth's obliquity as possibly the causal mechanism for ice age glaciation. Including this modulation effect on solar radiation, we have performed model simulations of climate change for the past 2 million years. Simulation results show that: (1) For the past 1 million years, temperature fluctuation cycles were dominated by a 100-Kyr period due to amplitude-frequency resonance effect of the obliquity; (2) From 2 to 1 million years ago, the amplitude-frequency interactions. of the obliquity were so weak that they were not able to stimulate a resonance effect on solar radiation; (3) Amplitude and frequency modulation analysis on solar radiation provides a series of resonance in the incoming solar radiation which may shift the glaciation cycles from 41-Kyr to 100-Kyr about 0.9 million years ago. These results are in good agreement with the marine and continental paleoclimate records. Thus, the proposed climate response to the combined amplitude and frequency modulation of the Earth's obliquity may be the key to understanding the glaciation puzzles in paleoclimatology.

  13. Increasing Efficiency of a 33 MW OTEC in Indonesia Using Flat-plate Solar Collector for the Seawater Heater

    OpenAIRE

    Setiawan, Iwan Rohman; Purnama, Irwan; Halim, Abdul

    2017-01-01

    This paper presents a design concept of Ocean Thermal Energy Conversion (OTEC) plant built in Mamuju, West Sulawesi, with 33 MWe and 7.1% of the power capacity and efficiency, respectively. The generated electrical power and the efficiency of OTEC plant are enhanced by a simulation of a number of derived formulas. Enhancement of efficiency is performed by increasing the temperature of the warm seawater toward the evaporator from 26˚C up to 33.5˚C using a flat-plate solar collector. The simula...

  14. Solar Air Heaters with Thermal Heat Storages

    OpenAIRE

    Saxena, Abhishek; Goel, Varun

    2013-01-01

    Solar energy can be converted into different forms of energy, either to thermal energy or to electrical energy. Solar energy is converted directly into electrical power by photovoltaic modules, while solar collector converts solar energy into thermal energy. Solar collector works by absorbing the direct solar radiation and converting it into thermal energy, which can be stored in the form of sensible heat or latent heat or a combination of sensible and latent heats. A theoretical study has be...

  15. Estimate of the energy and environment impacts attributed to solar thermal collectors in Brazil; Estimativa dos impactos energeticos e ambientais atribuida aos coletores solares termicos nas residencias brasileiras

    Energy Technology Data Exchange (ETDEWEB)

    Cardoso, Rafael Balbino [Universidade Federal de Itajuba (UNIFEI), Itabira, MG (Brazil)], E-mail: cardosorb@unifei.edu.br; Nogueira, Luiz Augusto Horta [Universidade Federal de Itajuba (UNIFEI), MG (Brazil)], E-mail: horta@unifei.edu.br

    2011-04-15

    The present study esteem the energy impacts, in terms of energy saving and reduction of peak demand, Real and Potential, as well as the environmental impacts, in terms of greenhouse gases (GHG) emission reduction, attributed to the use of solar thermal collectors in Brazil, in substitution to the electric showers. The evaluation of the energy saving, starting from the F Method, it was disaggregated in regional level, for the calculations of the solar fractions and distribution of the market and, starting from the energy saving and factor of national system emission, it was calculated the reductions of GHG effect. According to evaluations the use of solar thermal collectors in Brazil generated energy savings of the order of 1,073.2 GWh, what results in about 51,514 tCO{sub 2} of GHG emission reduction, equivalent to 104 thousand petroleum barrels, the year of 2008 and a reduction of peak demand of 1,220 MW, about 1.5% of the maximum demand registered on that year. It was verified, also, that Brazil uses less than 5% of the potential of solar thermal energy in the residential sector for water heating. (author)

  16. The Effect of the Angle of Inclination on the Efficiency in a Medium-Temperature Flat Plate Solar Collector

    Directory of Open Access Journals (Sweden)

    Orlando Montoya-Marquez

    2017-01-01

    Full Text Available In this experimental work, the effects of the inclination angle β and the (Ti − Ta/G on the efficiency and the UL-value were investigated on a medium-temperature flat plate solar collector. The experiments were based on steady-state energy balance, by heat flow calorimetry at indoor conditions and considering the standard American National Standard Institute/American Society of Heating Refrigerating and Air Conditioning Engineers (ANSI/ASHRAE 93-2010. The solar radiation was emulated by the Joule effect using a proportional integral derivative (PID control considering two conditions of the absorber temperature, Case 1: (To − Ti > 0, and Case 2: (To − Ti = 0. The inclination angles were 0°–90° and the (Ti − Ta/G were 0.044–0.083 m2·°C/W and 0.124–0.235 for Case 1 and Case 2, respectively. The variations of β and (Ti − Ta/G cause efficiency changes up to 0.37–0.45 (21.6% and 0.31–0.45 (45.0%, respectively, for Case 1. Also, the UL(β reached changes up to 10.1–12.0 W/m2·°C (19.2% and 8.4–12.0 W/m2·°C (41.7%, respectively, for Case 1. The most significant changes of UL(β/UL(90° vs. β were 8.0% at the horizontal position for Case 1, while for Case 2, the maximum change was 1.8% only. Therefore, the changes of the inclination angle cause significant variations of the convective flow patterns within the collector, which leads to considerable variation of the collector efficiency and its UL value.

  17. Standard Practice for Determining Resistance of Solar Collector Covers to Hail by Impact With Propelled Ice Balls

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1992-01-01

    1.1 This practice covers a procedure for determining the ability of cover plates for flat-plate solar collectors to withstand impact forces of falling hail. Propelled ice balls are used to simulate falling hailstones. This practice is not intended to apply to photovoltaic cells or arrays. 1.2 This practice defines two types of test specimens, describes methods for mounting specimens, specifies impact locations on each test specimen, provides an equation for determining the velocity of any size ice ball, provides a method for impacting the test specimens with ice balls, and specifies parameters that must be recorded and reported. 1.3 This practice does not establish pass or fail levels. The determination of acceptable or unacceptable levels of ice-ball impact resistance is beyond the scope of this practice. 1.4 The size of ice ball to be used in conducting this test is not specified in this practice. This practice can be used with various sizes of ice balls. 1.5 The categories of solar collector cover plat...

  18. Financial viability study using a heat pump as an alternative to support solar collector for water heating in Southeastern Brazil

    Energy Technology Data Exchange (ETDEWEB)

    Reis, Roberts Vinicius de Melo; Oliveira, Raphael Nunes; Machado, Luiz; Koury, Ricardo Nassau N. [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Dept. of Mechanical Engineering], E-mails: robertsreis@ufmg.br, luizm@demec.ufmg.br, koury@ufmg.br

    2010-07-01

    Along with related greenhouse effect environmental issues, constant problems changes in oil prices,make the use of solar energy an important renewable energy source. Brazil is a country which is privilege, considering the high rates of solar irradiation present throughout most of the entire national territory. Nevertheless, during certain times of the year, a solar energy deficit, leads solar systems to require electrical resistance support. The use of electrical resistance represents 23.5% of electric energy consumption and it presents a low residential energy efficiency. The purpose of this work is conducting a study of Brazilian States in the Southeastern region regarding the financial viability of replacing a resistive system combined with the use of solar collector and a heat pump. One such heat pump has been designed, constructed and tested experimentally. The average performance coefficient is equal to 2.10, a low value due to the use of a hermetic reciprocating compressor. Despite this low-moderate price coefficient of acquisition and installation of a heat pump, a return on investment in from 2.1 to 2.7 years can be expected. Whereas the equipment has a useful life of about 20 years, this period of return on investment is interesting. (author)

  19. Evidence for solar wind modulation of lightning

    Science.gov (United States)

    Scott, C. J.; Harrison, R. G.; Owens, M. J.; Lockwood, M.; Barnard, L.

    2014-05-01

    The response of lightning rates over Europe to arrival of high speed solar wind streams at Earth is investigated using a superposed epoch analysis. Fast solar wind stream arrival is determined from modulation of the solar wind V y component, measured by the Advanced Composition Explorer spacecraft. Lightning rate changes around these event times are determined from the very low frequency arrival time difference (ATD) system of the UK Met Office. Arrival of high speed streams at Earth is found to be preceded by a decrease in total solar irradiance and an increase in sunspot number and Mg II emissions. These are consistent with the high speed stream’s source being co-located with an active region appearing on the Eastern solar limb and rotating at the 27 d period of the Sun. Arrival of the high speed stream at Earth also coincides with a small (˜1%) but rapid decrease in galactic cosmic ray flux, a moderate (˜6%) increase in lower energy solar energetic protons (SEPs), and a substantial, statistically significant increase in lightning rates. These changes persist for around 40 d in all three quantities. The lightning rate increase is corroborated by an increase in the total number of thunder days observed by UK Met stations, again persisting for around 40 d after the arrival of a high speed solar wind stream. This result appears to contradict earlier studies that found an anti-correlation between sunspot number and thunder days over solar cycle timescales. The increase in lightning rates and thunder days that we observe coincides with an increased flux of SEPs which, while not being detected at ground level, nevertheless penetrate the atmosphere to tropospheric altitudes. This effect could be further amplified by an increase in mean lightning stroke intensity that brings more strokes above the detection threshold of the ATD system. In order to remove any potential seasonal bias the analysis was repeated for daily solar wind triggers occurring during the summer

  20. Influence of thermosiphonic flow with the height tank relative to a flat solar collector; Influencia del flujo termosifonico con la altura del termotanque relativo a un colector solar plano

    Energy Technology Data Exchange (ETDEWEB)

    Barrera C, Enrique; Arias T, Jorge E; Lugo L, Raul; Cano M, Francisco J [Universidad Autonoma Metropolitana-Iztapalapa, Mexico, D.F. (Mexico)

    2000-07-01

    In this work the effect of the height of the storage tank, with respect to a solar collector is studied. In order to obtain an adequate operation of the thermosiphonic flow system, the storage tank must be located above the upper part of the solar collector, although the height it has not been specified. In order to study this aspect, we studied the operation of a flat solar collector, in thermosiphonic regime, heated with a source of artificial energy (solar simulator based on tungsten lamps). The temperature profiles of storage deposit (temperature stratification) were analyzed as a function of different storage tank heights, which influence the storage tank temperatures profile and the inlet and outlet water temperature of the solar collector. These experiments also affect the thermosiphonic flow and, therefore the efficiency of the solar collector. In each experiment the same solar radiation level was used, which let us make sensitive comparisons regarding just the parameters of interest. The results obtained are reported. [Spanish] En este trabajo, se estudia el efecto de la altura del deposito de almacenamiento, respecto de un colector solar. Se sabe que para que se obtenga un funcionamiento adecuado de un sistema de flujo termosifonico, el deposito debe situarse por encima del colector solar, aunque no se ha especificado, cual puede ser una mejor altura. Con el fin de estudiar esta problematica en el presente trabajo se investigo el funcionamiento de un colector solar plano, en regimen termosifonico, accionado con una fuente de energia artificial (simulador solar basado en lamparas de tungsteno); se analizan los perfiles de temperatura del deposito de almacenamiento como funcion de las diferentes alturas estudiadas, los cuales son claves en el perfil de temperatura del agua de entrada y salida del colector solar, del flujo termosifonico alcanzado y por tanto de la eficiencia del colector solar. En cada experimento realizado, se utilizo el mismo nivel de

  1. Project, fabrication, assembly and tests of different prototypes for CPS compound parabolic solar collectors; Projeto, fabricacao, montagem e testes de diferentes prototipos de coletores solares parabolicos compostos CPCs

    Energy Technology Data Exchange (ETDEWEB)

    Neto, Jose H.M. [Centro Federal de Educacao Tecnologica de Minas Gerais (CEFET), Belo Horizonte, MG (Brazil). Dept. de Engenharia Mecanica]. E-mail: henrique@daem.des.cefemg.br

    2000-07-01

    This work presents the results of the experiment involving the design, fabrication, assembly and tests of composite parabolic solar collectors prototypes with acceptance half-angles of 3 deg C, 6.5 deg C, 11 deg C, 14 deg C and 19.5 deg C of the tube type absorber and 14 deg C rectangular absorber. Field test were performed on all the prototypes for determination of thermal efficiency, time constants and optical efficiencies represented by the modified incidence angles. Tests were performed for the determination of the heat transfer global coefficients on each prototype. (author)

  2. Evaluation of the solar water disinfection process (SODIS) against Cryptosporidium parvum using a 25-L static solar reactor fitted with a compound parabolic collector (CPC).

    Science.gov (United States)

    Fontán-Sainz, María; Gómez-Couso, Hipólito; Fernández-Ibáñez, Pilar; Ares-Mazás, Elvira

    2012-02-01

    Water samples of 0, 5, and 30 nephelometric turbidity units (NTU) spiked with Cryptosporidium parvum oocysts were exposed to natural sunlight using a 25-L static solar reactor fitted with a compound parabolic collector (CPC). The global oocyst viability was calculated by the evaluation of the inclusion/exclusion of the fluorogenic vital dye propidium iodide and the spontaneous excystation. After an exposure time of 8 hours, the global oocyst viabilities were 21.8 ± 3.1%, 31.3 ± 12.9%, and 45.0 ± 10.0% for turbidity levels of 0, 5, and 30 NTU, respectively, and these values were significantly lower (P 10 times).

  3. Enhancement of natural ventilation rate and attic heat gain reduction of roof solar collector using radiant barrier

    Energy Technology Data Exchange (ETDEWEB)

    Puangsombut, W.; Hirunlabh, J. [Building Scientific Research Center, King Mongkut' s University of Technology Thonburi, Bangmod, Thungkru, Bangkok 10140 (Thailand); Khedari, J.; Win, M.M. [South-East Asia University, 19/1 Petkasem Rd., Nongkhaem, Bangkok 10160 (Thailand); Zeghmati, B. [Centre d' Etudes Fondamentales-Groupe de Mechanique Acoustique et Instrumentation, Universite de Perpignan, 66870, Perpignan (France)

    2007-06-15

    Presented in this paper are the experimental results on natural ventilation flow rate enhancement and attic heat gain reduction of a roof solar collector equipped with a radiant barrier (RB). Investigation was conducted using an open ended inclined rectangular channel with an RB. The RB was used on the lower plate while the upper plate was heated with constant heat flux intensity. The channel dimensions are 1.5 x 0.70 x 0.19 m. The slope of the channel was fixed at 30 from horizontal plane. Four heat flux (190.5, 285.7, 380.9 and 476.2 W m{sup -2}) and five air gap space (3, 5, 7, 9 and 11 cm) were considered. Data analysis was made to determine the free convection heat transfer coefficient and induced airflow rate using two dimensionless parameters, viz., Nusselt number (Nu) and Reynolds number (Re). The Nu and Re were correlated as a function of Ra sin30 and channel aspect ratio defined as the ratio of air gap space to the channel length. The relations obtained were as follows: Nu=0.371(Ra sin 30){sup 0.2223}(S/L){sup -0.0469} and Re=191.68(Ra sin30){sup 0.1213}(S/L){sup -0.085}. When compared to a conventional roof solar configuration with gypsum board on the lower part, it was observed that the use of RB increased convective heat transfer and airflow rate by about 40-50%, thereby increasing heat transfer reduction through the lower plate by about 50%. The developed correlations are useful for the design of such open-ended channels like the roof solar collector for passive ventilation of houses. (author)

  4. Solar wind modulation of UK lightning

    Science.gov (United States)

    Davis, Chris; Harrison, Giles; Lockwood, Mike; Owens, Mathew; Barnard, Luke

    2013-04-01

    The response of lightning rates in the UK to arrival of high speed solar wind streams at Earth is investigated using a superposed epoch analysis. The fast solar wind streams' arrivals are determined from modulation of the solar wind Vy component, measured by the Advanced Composition Explorer (ACE) spacecraft. Lightning rate changes around these event times are then determined from the very low frequency Arrival Time Difference (ATD) system of the UK Met Office. Arrival of high speed streams at Earth is found to be preceded by a decrease in total solar irradiance and an increase in sunspot number and Mg II emissions. These are consistent with the high speed stream's source being co-located with an active region appearing on the Eastern solar limb and rotating at the 27 day rate of the Sun. Arrival of the high speed stream at Earth also coincides with a rapid decrease in cosmic ray flux and an increase in lightning rates over the UK, persisting for around 40 days. The lightning rate increase is corroborated by an increase in the total number of thunder days observed by UK Met stations, again for around 40 days after the arrival of a high speed solar wind stream. This increase in lightning may be beneficial to medium range forecasting of hazardous weather.

  5. Solar Thermal Power.

    Science.gov (United States)

    McDaniels, David K.

    The different approaches to the generation of power from solar energy may be roughly divided into five categories: distributed collectors; central receivers; biomass; ocean thermal energy conversion; and photovoltaic devices. The first approach (distributed collectors) is the subject of this module. The material presented is designed to…

  6. Novel double-stage high-concentrated solar hybrid photovoltaic/thermal (PV/T) collector with nonimaging optics and GaAs solar cells reflector

    International Nuclear Information System (INIS)

    Abdelhamid, Mahmoud; Widyolar, Bennett K.; Jiang, Lun; Winston, Roland; Yablonovitch, Eli; Scranton, Gregg; Cygan, David; Abbasi, Hamid; Kozlov, Aleksandr

    2016-01-01

    Highlights: • A novel hybrid concentrating photovoltaic thermal (PV/T) collector is developed. • Thermal component achieves 60× concentration using nonimaging optics. • GaAs solar cells used as spectrally selective mirrors for low energy photons. • Thermal efficiencies of 37% at 365 °C and electrical efficiencies of 8% achieved. • Combined electric efficiency reaches 25% of DNI for system cost of $283.10/m 2. - Abstract: A novel double stage high-concentration hybrid solar photovoltaic thermal (PV/T) collector using nonimaging optics and world record thin film single-junction gallium arsenide (GaAs) solar cells has been developed. We present a detailed design and simulation of the system, experimental setup, prototype, system performance, and economic analysis. The system uses a parabolic trough (primary concentrator) to focus sunlight towards a secondary nonimaging compound parabolic concentrator (CPC) to simultaneously generate electricity from single junction GaAs solar cells, as well as high temperature dispatchable heat. This study is novel in that (a) the solar cells inside the vacuum tube act as spectrally selective mirrors for lower energy photons to maximize the system exergy, and (b) secondary concentrator allows the thermal component to reach a concentration ratio ∼60×, which is significantly higher than conventional PV/T concentration ratios. The maximum outlet temperature reached was 365 °C, and on average the thermal efficiency of the experiment was around 37%. The maximum electrical efficiency was around 8%. The total system electricity generation is around 25% of incoming DNI, by assuming the high temperature stream is used to power a steam turbine. The installed system cost per unit of parabolic trough aperture area is $283.10 per m 2 .

  7. German co-operation in the IEA WG 'Materials in Solar Thermal Collectors'. Final report; Deutsche Mitarbeit in der IEA - Arbeitsgruppe 'Materials in Solar Thermal Collectors'. Abschlussbericht

    Energy Technology Data Exchange (ETDEWEB)

    Koehl, M.; Heck, M.; Kuebler, V.; Steinhart, J.

    2000-07-01

    To effectively select, use and maintain a material in a given application, its degradation under service conditions must be predicted prior to use. Preferably, the durability of the material should be expressed quantitatively in terms of an expected service life. Durability in this case is the ability of a material to withstand deterioration caused by all external factors in the environment, which may influence the performance of the material under service conditions. Service life is defined as the period of time after installation during which specific material properties important for the performance of the material meet or exceed minimum acceptable values. The present recommended qualification procedure for solar absorber surface durability is based on the conduct of a series of short term durability tests. During a test the optical performance of absorber surface tested is determined by measuring its solar absorptance and thermal emittance. From the loss in optical performance of absorber surface, its failure time in the test performed is assessed and compared with the shortest acceptable failure time set by the design service life of absorber. Design service life, performance requirement defining failure time in terms of loss in optical performance, classification of type and levels of environmental stress are set under the assumption, that the absorber surface tested will be installed in a flat plate solar collector for use in domestic hot water systems. (orig.)

  8. The Vertical-Tube Solar Collector: A Low-Cost Design Suitable for Temperate High-Latitude Locations

    Directory of Open Access Journals (Sweden)

    Luis Juanicó

    2014-01-01

    Full Text Available A new low-cost solar collector based on thick (4.5′′ vertical tubes related to the previous design based on long 1.5′′ plastic hoses connected directly between water-grid supply and consumption is presented. This novel design could noticeably improve its performance for temperate locations mid and high latitudes, as was demonstrated by dynamic thermal modeling. This tool has been useful for understanding the particular characteristics of this kind of water-pond collector and besides, for noticeably improving its performance by optimizing its parameters, like tube diameter and number of glazing layers. By this way, the optimized design could fully satisfy the household demand up to midnight along the whole year for Buenos Aires (35°S and during summers (remaining as a useful preheater for the whole year for Ushuaia (55°S. Besides, its high simplicity makes it available for user’s own construction, costing down 50 dollars for a single-family unit.

  9. Optical and thermal performance of large-size parabolic-trough solar collectors from outdoor experiments: A test method and a case study

    International Nuclear Information System (INIS)

    Valenzuela, Loreto; López-Martín, Rafael; Zarza, Eduardo

    2014-01-01

    This article presents an outdoor test method to evaluate the optical and thermal performance of parabolic-trough collectors of large size (length ≥ 100 m), similar to those currently installed in solar thermal power plants. Optical performance in line-focus collectors is defined by three parameters, peak-optical efficiency and longitudinal and transversal incidence angle modifiers. In parabolic-troughs, the transversal incidence angle modifier is usually assumed equal to 1, and the incidence angle modifier is referred to the longitudinal incidence angle modifier, which is a factor less than or equal to 1 and must be quantified. These measurements are performed by operating the collector at low fluid temperatures for reducing heat losses. Thermal performance is measured during tests at various operating temperatures, which are defined within the working temperature range of the solar field, and for the condition of maximum optical response. Heat losses are measured from both the experiments performed to measure the overall efficiency and the experiments done by operating the collector to ensure that absorber pipes are not exposed to concentrated solar radiation. The set of parameters describing the performance of a parabolic-trough collector of large size has been measured following the test procedures proposed and explained in the article. - Highlights: • Outdoor test procedures of parabolic-trough solar collector (PTC) of large size working at high temperature are described. • Optical performance measured with cold fluid temperature and thermal performance measured in the complete temperature range. • Experimental data obtained in the testing of a PTC prototype are explained

  10. Investigation of a hybrid PVT air collector system

    Science.gov (United States)

    Haddad, S.; Touafek, K.; Mordjaoui, M.; Khelifa, A.; Tabet, I.

    2017-02-01

    The photovoltaic thermal hybrid (PVT) collectors, which simultaneously produce electricity and heat, are an alternative to photovoltaic modules and thermal collectors installed separately. Indeed, the heat extracted from the solar cell is used to heat water or air, thereby cooling the cell, and thus increasing its energy efficiency. This paper deals with a hybrid PVT air collector in which a new design has been proposed and tested. Its principle is based on the return of the preheating air to a second heating. The air thus passes twice under the solar cells before being evacuated to the outside of the collector (for space heating). The system is modular and expandable to cover large spaces to be heated. The experimental results of this novel design are presented and discussed under both normal and forced circulation. This technique of air return shows favorable results in terms of the quality of the heated air and electric power generation.

  11. Sensitivity analysis in the test of a parabolic trough solar collector (PTSC) with flat null-screens

    Science.gov (United States)

    Campos-García, Manuel; Huerta-Carranza, Oliver; Díaz-Uribe, José Rufino; Moreno-Oliva, Víctor Iván.; Santiago-Alvarado, Agustín.; Peña-Conzueloa, Andrés.

    2016-09-01

    In this work we proposed a flat null-screen method to test parabolic trough solar collectors (PTSC). The null-screen testing method measures the slope of the test surface and by a numerical integration procedure the shape of the test surface can be obtained. In this work, we show that the test can be sensitive to small surface deformations, such as those caused by sinusoidal deformations with different amplitudes and spatial periods introduced on the PTSC surface. These calculations also show that the attainable theoretical slope accuracy in the rms sense is about 0.34 mrad. This value was obtained under the assumption that is possible to achieve a 1-pixel resolution on the measurement of the position departures of the centroids of the targets of the null-screen.

  12. An Analysis of Unglazed Transpired Solar Collectors Based on Exergetic Performance Criteria

    OpenAIRE

    Motahar, Sadegh

    2010-01-01

    In this paper, an exergetic performance analysis of unglazed transpired collectors (UTC), as well as an exergetic optimization of a typical UTC is performed. The impact of the hot tap water load pattern in the industrial hall on the energy yield from solar collectors

    Directory of Open Access Journals (Sweden)

    Fidorów-Kaprawyl Natalia

    2017-01-01

    Full Text Available The systems using solar energy, popular in Poland, can be used to supply hot water for the installation used by employees of industrial halls. In manufacturing plants, employing a large number of people, the demand for hot water is practically constant throughout the year and is characterized by periodic use at the end of each work shift. Dynamics of the hot water consumption depends on the number of shifts as well as working days and holidays. Additionally the maximum hot tap water demand occurs in the whole period of installation operation. In polish climatic conditions the solar collectors’ systems have the largest capacity in the summer, while in winter they need to be assisted. Beside that the supply of renewable energy is uneven and depends on weather conditions. In the paper the one-hour step analysis concerning the dependence of the load pattern of the hot tap water preparation system on the energy yield from solar collectors had been performed.

  13. Experimental investigation of the impact of airborne dust deposition on the performance of solar photovoltaic (PV) modules

    Science.gov (United States)

    Jiang, Hai; Lu, Lin; Sun, Ke

    2011-08-01

    Deposition of airborne dust on outdoor photovoltaic (PV) modules may decrease the transmittance of solar cell glazing and cause a significant degradation of solar conversion efficiency of PV modules. Previous studies of this issue indicated that dust deposition is closely related to the tilt angle of solar collector, exposure period, site climate conditions, wind movement and dust properties. However, few studies considered the influence of the properties of PV module itself on dust deposition and efficiency degradation, such as the cell types and surface materials. This experimental work aimed to study the dust accumulation onto different types of solar PV modules and the corresponding efficiency degradation. The experiment was designed and conducted in the laboratory with a sun simulator and a test chamber. The degradation of PV module efficiency caused by dust deposition under various conditions was investigated. The results indicated that dust pollution has a significant impact on PV module output. With dust deposition density increasing from 0 to 22 g m -2, the corresponding reduction of PV output efficiency grew from 0 to 26%. The reduction of efficiency has a linear relationship with the dust deposition density, and the difference caused by cell types was not obvious. When the dust deposition density was fixed, the reductions of output efficiency at relatively lower or higher solar densities were much more severe. Moreover, the surface material may influence dust deposition and accumulation considerably. The poly-crystalline silicon module packaged with epoxy degraded faster than other modules with glass surface under the same dust concentration.

  14. Hybrid utilization of solar energy. Part 2. Performance analyses of heating system with air hybrid collector; Taiyo energy no hybrid riyo ni kansuru kenkyu. 2. Kuki shunetsu hybrid collector wo mochiita danbo system no seino hyoka

    Energy Technology Data Exchange (ETDEWEB)

    Yoshinaga, M.; Okumiya, M. [Nagoya University, Nagoya (Japan)

    1996-10-27

    For the effective utilization of solar energy at houses, a heating system using an air hybrid collector (capable of simultaneously performing heat collection and photovoltaic power generation). As the specimen house, a wooden house of a total floor area of 120m{sup 2} was simulated. Collected air is fanned into a crushed stone heat accumulator (capable of storing one day`s collection) or into a living room. The output of solar cell arrays is put into a heat pump (capable of handling a maximum hourly load of 36,327kJ/h) via an inverter so as to drive the fan (corresponding to average insolation on the heat collecting plate of 10.7MJ/hm{sup 2} and heat collecting efficiency of 40%), and shortage in power if any is supplied from the system interconnection. A hybrid collector, as compared with the conventional air collector, is lower in thermal efficiency but the merit that it exhibits with respect to power generation is far greater than what is needed to counterbalance the demerit. When the hybrid system is in heating operation, there is an ideal heat cycle of collection, accumulation, and radiation when the load is light, but the balance between accumulation and radiation is disturbed when the load is heavy. 4 refs., 8 figs., 3 tabs.

  15. Estimation of the temperature, heat gain and heat loss by solar parabolic trough collector under Algerian climate using different thermal oils

    International Nuclear Information System (INIS)

    Ouagued, Malika; Khellaf, Abdallah; Loukarfi, Larbi

    2013-01-01

    Highlights: • Estimation of direct solar radiations for different tracking systems at six typical locations in Algeria. • PTC thermal model uses energy balances from the HTF to the atmosphere. • The model depends on the collector type, nature of HTF, optical properties, and ambient conditions. • Estimation of temperature, heat gain and energy cost of thermal oils used in the model. • Comparison between monthly mean heat gain of the various thermal oils for six Algerian locations. - Abstract: Algeria is blessed with a very important renewable, and more particularly solar, energy potential. This potential opens for Algeria reel opportunities to cope with the increasing energy demand and the growing environmental problems link to the use of fossil fuel. In order to develop and to promote concrete actions in the areas of renewable energy and energy efficiency, Algeria has introduced a national daring program for the period 2011–2030. In this program, solar energy, and more particularly solar thermal energy plays an important role. In this paper, the potential of direct solar irradiance in Algeria and the performance of solar parabolic trough collector (PTC) are estimated under the climate conditions of the country. These two factors are treated as they play an important role in the design of solar thermal plant. In order to determine the most promising solar sites in Algeria, monthly mean daily direct solar radiation have been estimated and compared for different locations corresponding to different climatic region. Different tilted and tracking collectors are considered so as to determine the most efficient system for the PTC. In order to evaluate the performance of a tracking solar parabolic trough collector, a heat transfer model is developed. The receiver, heat collector element (HCE), is divided into several segments and heat balance is applied in each segment over a section of the solar receiver. Different oils are considered to determine the thermal

  16. Performance analysis of an Integrated Solar Combined Cycle using Direct Steam Generation in parabolic trough collectors

    International Nuclear Information System (INIS)

    Montes, M.J.; Rovira, A.; Munoz, M.; Martinez-Val, J.M.

    2011-01-01

    Highlights: → Solar hybridization improves the performance of CCGT in a very hot and dry weather. → The scheme analyzed is a DSG parabolic trough field coupled to the Rankine cycle. → An annual simulation has been carried out for two locations: Almeria and Las Vegas. → Economical analysis shows that this scheme is a cheaper way to exploit solar energy. → For that, solar hybridization must be limited to a small fraction of the CCGT power. - Abstract: The contribution of solar thermal power to improve the performance of gas-fired combined cycles in very hot and dry environmental conditions is analyzed in this work, in order to assess the potential of this technique, and to feature Direct Steam Generation (DSG) as a well suited candidate for achieving very good results in this quest. The particular Integrated Solar Combined Cycle (ISCC) power plant proposed consists of a DSG parabolic trough field coupled to the bottoming steam cycle of a Combined Cycle Gas Turbine (CCGT) power plant. For this analysis, the solar thermal power plant performs in a solar dispatching mode: the gas turbine always operates at full load, only depending on ambient conditions, whereas the steam turbine is somewhat boosted to accommodate the thermal hybridization from the solar field. Although the analysis is aimed to studying such complementary effects in the widest perspective, two relevant examples are given, corresponding to two well-known sites: Almeria (Spain), with a mediterranean climate, and Las Vegas (USA), with a hot and dry climate. The annual simulations show that, although the conventional CCGT power plant works worse in Las Vegas, owing to the higher temperatures, the ISCC system operates better in Las Vegas than in Almeria, because of solar hybridization is especially well coupled to the CCGT power plant in the frequent days with great solar radiation and high temperatures in Las Vegas. The complementary effect will be clearly seen in these cases, because the thermal

  17. Performance tests and efficiency analysis of Solar Invictus 53S - A parabolic dish solar collector for direct steam generation

    Science.gov (United States)

    Jamil, Umer; Ali, Wajahat

    2016-05-01

    This paper presents the results of performance tests conducted on Solar Invictus 53S `system'; an economically effective solar steam generation solution designed and developed by ZED Solar Ltd. The system consists of a dual axis tracking parabolic solar dish and bespoke cavity type receiver, which works as a Once Through Solar Steam Generator `OTSSG' mounted at the focal point of the dish. The overall performance and efficiency of the system depends primarily on the optical efficiency of the solar dish and thermal efficiency of the OTSSG. Optical testing performed include `on sun' tests using CCD camera images and `burn plate' testing to evaluate the sunspot for size and quality. The intercept factor was calculated using a colour look-back method to determine the percentage of solar rays focused into the receiver. Solar dish tracking stability tests were carried out at different times of day to account for varying dish elevation angles and positions, movement of the sunspot centroid was recorded and logged using a CCD camera. Finally the overall performance and net solar to steam efficiency of the system was calculated by experimentally measuring the output steam parameters at varying Direct Normal Insolation (DNI) levels at ZED Solar's test facility in Lahore, Pakistan. Thermal losses from OTSSG were calculated using the known optical efficiency and measured changes in output steam enthalpy.

  18. Desinfestação de substratos com a utilização de coletor solar Utilization of solar collector for treatment of plant growth substrates

    Directory of Open Access Journals (Sweden)

    Raquel Ghini

    1992-01-01

    Full Text Available Coletores solares planos constituídos de caixas de madeira com canaletas de chapa de alumínio, onde se coloca o substrato e se cobre com plástico transparente, foram testados quanto ao controle de Sclerotium rolfsii, Rhizoctonia solani, Verticillium sp., Meloidogyne arenaria e Cyperus rotundus (tiririca. Dependendo da intensidade de radiação solar, é necessário um dia para desinfestação do substrato com S. rolfsii e dois dias para R. solani, Verticillium sp. e M. arenaria.Flat solar collectors were tested for the control of Sclerotium rolfsii, Rhizoctonia solani, VerticiUium sp., Meloidogyne arenaria and Cyperus rotundus (nut sedge. The equipment developed comprises, basically, gutters of aluminum with termic liner of glass wool and transparent plastic cover. The results showed that, depending upon the solar radiation, one day is required for the disinfestations of substrate infested with S. rolfsii and nut sedge, and two days for R. solani, Verticillium sp. and M. arenaria.

  19. The performance of a novel flat heat pipe based thermal and PV/T (photovoltaic and thermal systems) solar collector that can be used as an energy-active building envelope material

    International Nuclear Information System (INIS)

    Jouhara, H.; Milko, J.; Danielewicz, J.; Sayegh, M.A.; Szulgowska-Zgrzywa, M.; Ramos, J.B.; Lester, S.P.

    2016-01-01

    A novel flat heat pipe design has been developed and utilised as a building envelope and thermal solar collector with and without (PV) bonded directly to its surface. The design of the new solar collector has been validated through full scale testing in Cardiff, UK where solar/thermal, uncooled PV and PV/T tests were carried out on three identical systems, simultaneously. The tests showed a solar/thermal energy conversion efficiency of around 64% for the collector with no PV and 50% for the system with the PV layer on it. The effect of cooling on the solar/electrical energy conversion efficiency was also investigated and an efficiency increase of about 15% was recorded for the cooled PV system due to the provided homogenous cooling. The new flat heat pipe solar collector is given the name “heat mat” and, in addition to being an efficient solar collector type, it is also designed to convert a building envelope materials to become energy-active. A full size roof that utilise this new building envelope material is reported in this paper to demonstrate the way this new collector is integrated as a building envelope material to form a roof. A thermal absorption test, in a controlled environment, from the ambient to the heat mat with no solar radiation is also reported. The test has proved the heat mat as an efficient thermal absorber from the ambient to the intermediate fluid that deliver the heat energy to the heat pump system. - Highlights: • A new flat heat pipe PV/T system that can be used as building materials is reported. • The new solar collector enhanced the performance of the PV by about 15%. • The new solar collector is capable of absorbing heat from ambient efficiently. • The new system is efficient from the solar/thermal conversion point of view.

  1. Designing of nomographs for determination of solar air collector's absorber size

    Directory of Open Access Journals (Sweden)

    Peter Tauš

    2007-04-01

    Full Text Available Solar systems are able to save an important part of costs for heating, mainly in large objects. During the decision about the possibility to install a solar system to a building, the investor will be interested mainly in the estimation of the costs for the system. One of the main investments is to the absorber a basic part of the solar system.The proper size of the absorber indicates a performance of the whole system but also a significant part of the input investment costs. Nomographs, presented in this project, that were created according the detailed calculation, will significantly speed up stating of the size of the absorber of the solar system.

  2. Dielectric compound parabolic concentrating solar collector with frustrated total internal reflection absorber

    Science.gov (United States)

    Hull, J. R.

    Since its introduction, the concept of nonimaging solar concentrators, as exemplified by the compound parabolic concentrator (CPC) design, has greatly enhanced the ability to collect solar energy efficiently in thermal and photovoltaic devices. When used as a primary concentrator, a CPC can provide significant concentration without the complication of a tracking mechanism and its associated maintenance problems. When used as a secondary, a CPC provides higher total concentration, or for a fixed concentration, tolerates greater tracking error in the primary.

  3. Influence of Nano-Fluid and Receiver Modification in Solar Parabolic Trough Collector Performance

    Science.gov (United States)

    Dharani Kumar, M.; Yuvaraj, G.; Balaji, D.; Pravinraj, R.; shanmugasundaram, Prabhu

    2018-02-01

    Utilization of natural renewal sources in India is very high over the past decades. Solar power is a prime source of energy available plenty in the world. In this work solar energy is modified into thermal energy by using copper absorber tube with fins. Due to low heat transfer coefficient results leading to higher thermal losses and lower thermal efficiency. In order to increase the heat transfer coefficient copper receiver tube with fins is used and as well as solid has higher thermal conductivity compare to fluid (Tio2) nano fluid is used to improve the heat transfer rate. The analyses have been carried out and take the account of parameters such as solar radiation with time variation, mass flow rate of water, temperatures.

  4. Evaluation of the Solar Water Disinfection Process (SODIS) Against Cryptosporidium parvum Using a 25-L Static Solar Reactor Fitted with a Compound Parabolic Collector (CPC)

    Science.gov (United States)

    Fontán-Sainz, María; Gómez-Couso, Hipólito; Fernández-Ibáñez, Pilar; Ares-Mazás, Elvira

    2012-01-01

    Water samples of 0, 5, and 30 nephelometric turbidity units (NTU) spiked with Cryptosporidium parvum oocysts were exposed to natural sunlight using a 25-L static solar reactor fitted with a compound parabolic collector (CPC). The global oocyst viability was calculated by the evaluation of the inclusion/exclusion of the fluorogenic vital dye propidium iodide and the spontaneous excystation. After an exposure time of 8 hours, the global oocyst viabilities were 21.8 ± 3.1%, 31.3 ± 12.9%, and 45.0 ± 10.0% for turbidity levels of 0, 5, and 30 NTU, respectively, and these values were significantly lower (P 10 times). PMID:22302852

  5. Experimental study of temperature stratification in an integrated collector-storage solar water heater with two horizontal tanks

    Energy Technology Data Exchange (ETDEWEB)

    Madhlopa, A. [Department of Physics and Biochemical Sciences, Malawi Polytechnic, P/Bag 303, Blantyre 3 (Malawi); Mgawi, R. [Department of Mechanical Engineering, Malawi Polytechnic, P/Bag 303, Blantyre 3 (Malawi); Taulo, J. [Malawi Industrial Research and Technology Development Centre, P.O. Box 357, Blantyre (Malawi)

    2006-08-15

    The effect of tank-interconnection geometry on temperature stratification in an integrated collector-storage solar water (ICSSW) heater with two horizontal cylindrical tanks has been studied. The tanks were parallel to each other, and separated horizontally and vertically, with the lower tank fitted directly below a glass cover, and half of the upper tank insulated. In addition, a truncated parabolic concentrator was fitted below the tanks, with its focal line along the axis of the upper tank. The heater was tested outdoors with the two tanks connected in parallel (P), and S1- and S2-series configurations, with and without hot water draw-off. Water temperature was monitored during solar collection and hot water draw-offs. For the heat charging process, it was found that only the lower tank exhibited temperature stratification in the P- and S1-tank modes of operation. There was satisfactory temperature stratification in both tanks in the S2-tank configuration. For the hot water draining process, the P-tank configuration exhibited some degree of stratification in both tanks. A significant loss of stratification was observed in the lower tank, with the upper tank exhibiting practical stratification, when the system was operated in the S1-tank mode. The S2-tank interconnection maintained a satisfactory degree of temperature stratification in both tanks. So, the S2-tank mode of operation was most effective in promoting practical temperature stratification in both tanks during solar collection and hot water draw-offs. Other results are presented and discussed in this paper. (author)

  6. Performance enhancement of solar module by cooling: An experimental investigation

    OpenAIRE

    P G Nikhil, M Premalatha

    2012-01-01

    The study evaluates the silicone oil cooling of the solar module surface. Solar module with maximum power of 7W was employed for cooling. This paper summarizes the result of an outdoor experiment. The experiments were conducted in batch mode, with the cooling medium spread on the module surface at different thickness from 0mm to 6mm. The performance of the module, throughout the day, for different thickness of the medium is reported. The study also presents a mathematical model, predicting th...

  7. Experimental anaerobic digestion generator coupled at a plan plates solar collector; Biodigestor experimental acoplado a coletor solar de placas planas

    Energy Technology Data Exchange (ETDEWEB)

    Kaneshiro, Tsuneharu [Brasilia Univ., DF (Brazil); Venanzi, D. [Sao Paulo Univ., Sao Carlos, SP (Brazil). Escola de Engenharia; Medeiros, J.T.N. de [Rio Grande do Norte Univ., Natal, RN (Brazil)

    1987-12-31

    Analysis of results of research in course in solar energy used as heat source to anaerobic degradation in organic matter are presented; water is circulated around the generator to rise and maintain a constant process. (author). 16 refs., 2 figs

  8. Development of 400/sup 0/F sealants for flat plate solar collector construction and installation. Final report, 1 October 1978-30 September 1979

    Energy Technology Data Exchange (ETDEWEB)

    Morris, L.; Schubert, R.J.

    1980-03-01

    Twenty candidate sealants representing ten different polymer types were evaluated as potential solar collector sealants. Polymer types tested included epichlorohydrin rubber, EPDM rubber, silicone, polysulfide, acrylate rubber, and a fluoroelastomer. Initial screening of sealants consisted of measuring high temperature stability and adhesion retention. Several sealant compositions exhibited satisfactory performance in these tests and were selected for further evaluation. These materials were based on an EPDM rubber, a Viton fluoroelastomer, and silicone polymers. Further testing of these candidate materials included determination of adhesion retention under uv/water/heat conditions, fogging temperature, low temperature flexibility, and physical properties. Four silicone-based materials appeared to be suitable candidates for sealing solar collectors. These include Dow Corning 90-006-02 and 3120, General Electric 1200, and PR-1939 from Products Research and Chemical Corporation.

  9. On the applications of nanofluids to enhance the performance of solar collectors: A comparative analysis of Atangana-Baleanu and Caputo-Fabrizio fractional models

    Science.gov (United States)

    Sheikh, Nadeem Ahmad; Ali, Farhad; Khan, Ilyas; Gohar, Madeha; Saqib, Muhammad

    2017-12-01

    In the modern era, solar energy has gained the consideration of researchers to a great deal. Apparently, the reasons are twofold: firstly, the researchers are concerned to design new devices like solar collectors, solar water heaters, etc. Secondly, the use of new approaches to improve the performance of solar energy equipment. The aim of this paper is to model the problem of the enhancement of heat transfer rate of solar energy devices, using nanoparticles and to find the exact solutions of the considered problem. The classical model is transformed to a generalized model using two different types of time-fractional derivatives, namely the Caputo-Fabrizio and Atangana-Baleanu derivatives and their comparative analysis has been presented. The solutions for the flow profile and heat transfer are presented using the Laplace transform method. The variation in the heat transfer rate has been observed for different nanoparticles and their different volume fractions. Theoretical results show that by adding aluminum oxide nanoparticles, the efficiency of solar collectors may be enhanced by 5.2%. Furthermore, the effect of volume friction of nanoparticles on velocity distribution has been discussed in graphical illustrations. The solutions are reduced to the corresponding classical model of nanofluid.

  10. COMBINED UNCOVERED SHEET-AND-TUBE PVT-COLLECTOR SYSTEM WITH BUILT-IN STORAGE WATER HEATER

    Directory of Open Access Journals (Sweden)

    Muhammad Abid

    2012-02-01

    Full Text Available This work describes the design and investigation of a simple combined uncovered sheet-and-tube photo-voltaic-thermal (PVT collector system. The PVT-collector system consists of a support, standard PV module (1.22x0.305m, area=0.37m2, fill factor=0.75, sheet-and-tube water collector and storage tank-heater. The collector was fixed under PV module. Inclination angle of the PVT-collector to the horizontal plane was 45 degree. The storage tank-heater played double role i.e. for storage of hot water and for water heating. The PVT-collector system could work in the fixed and tracking modes of operation. During investigations of PVT-collector in natural conditions, solar irradiance, voltage and current of PV module, ambient temperature and water temperature in storage tank were measured. Average thermal and electrical powers of the PVT-collector system at the tracking mode of operation observed were 39W and 21W, with efficiencies of 15% and 8% respectively at the input power of 260W. The maximum temperature of the water obtained was 42oC. The system was observed efficient for low-temperature applications. The PVT-collector system may be used as a prototype for design of PVT-collector system for domestic application, teaching aid and for demonstration purposes.

  11. Hybrid photovoltaic and thermoelectric module for high concentration solar system

    Science.gov (United States)

    Tamaki, Ryo; Toyoda, Takeshi; Tamura, Yoichi; Matoba, Akinari; Minamikawa, Toshiharu; Tokuda, Masayuki; Masui, Megumi; Okada, Yoshitaka

    2017-09-01

    A photovoltaic (PV) and thermoelectric (TE) hybrid module was developed for application to high concentration solar systems. The waste heat from the solar cells under concentrated light illumination was utilized to generate additional electricity by assembling TE devices below the multi-junction solar cells (MJSCs). Considering the high operating temperature of the PV and TE hybrid module compared with conventional concentrator PV modules, the TE device could compensate a part of the MJSC efficiency degradation at high temperature. The performance investigation clarified the feasibility of the hybrid PV and TE module under highly concentrated sunlight illumination.

  12. Modelling of Microclimate in collectors

    DEFF Research Database (Denmark)

    Holck, Ole

    1996-01-01

    Abstract It is important to avoid condensation in solar collectors, most of all because wetness of the absorber can damage the selective surface and cause corrosion on the absorber plate. During night time the cover of collectors will cool below ambient temperature due to thermal radiation...

  13. Comparison of Degradation on Aluminum Reflectors for Solar Collectors due to Outdoor Exposure and Accelerated Aging

    Directory of Open Access Journals (Sweden)

    Johannes Wette

    2016-11-01

    Full Text Available Reflectors for concentrated solar thermal technologies need to withstand 20 or even 30 years of outdoor exposure without significant loss of solar specular reflectance. In order to test the durability of innovative reflectors within a shorter period of time, an accelerated aging methodology is required. The problem with accelerated testing is that poor correlation between laboratory and field test results has been achieved in the past. This is mainly because unrealistic degradation mechanisms are accelerated in the weathering chambers. In order to define a realistic testing procedure, a high number of accelerated aging tests have been performed on differently coated aluminum reflectors. The degradation mechanisms of the accelerated tests have been classified and systematically compared to samples that have been exposed at nine different exposure sites outdoors. Besides the standardized aging tests, innovative aging procedures have been developed in such way that the agreement to the degradation pattern observed outdoors is increased. Although degradation depends on materials and location, five generic degradation mechanisms were detected. Standardized tests only reproduced one or two of the five mechanisms detected outdoors. Additionally, several degradation effects that were not observed outdoors appeared. The innovative accelerated aging tests of artificially soiled samples were able to reproduce three of the five mechanisms observed outdoors, presenting a much more realistic overall degradation pattern.

  14. Irreversibility Analysis of Non Isothermal Flat Plate Solar Collectors for Air Heating with a Dimensionless Model

    Directory of Open Access Journals (Sweden)

    Baritto-Loreto Miguel Leonardo

    2013-04-01

    Full Text Available En el presente trabajo, el modelo adimensional desarrollado y validado por Baritto y Bracamonte (2012 para describir el comportamiento térmico de colectores solares de placas planas sin cubierta transparente, se complementa con la ecuación adimensional de balance de entropía para un elemento diferencial de colector solar. El modelo se resuelve para un amplio rango de valores de relaciones de aspecto y número de flujo de masa. A partir de los resultados del modelo se desarrolla un análisis detallado de la influencia de estos parámetros sobre la distribución de irreversibilidades internas a lo largo del colector. Adicionalmente se estudia la influencia de estos parámetros sobre los números de generación de entropía por fricción viscosa, por transferencia de calor y total. Se encuentra que existen combinaciones de los parámetros antes mencionados, para los cuales, la operación del colector es termodinámicamente óptima para números de flujo de masa elevados.

  15. Modeling and experimental validation of the solar loop for absorption solar cooling system using double glazed collectors

    OpenAIRE

    2010-01-01

    Abstract Solar cooling applied to buildings is without a doubt an interesting alternative for reducing energy consumption in traditional mechanical steam compression air conditioning systems. The study of these systems should have a closely purely fundamental approach including the development of numerical models in order to predict the overall installation performance. The final objective is to estimate cooling capacity, power consumption, and overall installation performance with...

  16. Solar-collector-materials exposure to the IPH site environment. Volume 1. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Morris, V.L.

    1982-01-01

    In-situ environmental exposure tests were conducted at nine proposed intermediate-temperature Industrial Process Heat (IPH) sites. Three types of reflector materials were evaluated for survivability at the nine sites: second-surface silvered glass, aluminized acrylic FEK-244 film on aluminumsubstrate and Alzak (electropolished aluminum) on aluminium substrate. Black chrome absorber material and low-iron float glass were evaluated for thermal, photochemical, and environmental degradation. The reflector specimens were monitored for decreases in specular and hemispherical reflectance due to soil buildup. The absorber material was evaluated for changes in solar absorptivity and emissivity, and the float glass was monitored for changes in transmissivity. Surface and subsurface defects on all materials were examined microscopically and, where deemed of note, were documented photographically.

  17. Mitigation of soiling losses in solar collectors: Removal of surface-adhered dust particles using an electrodynamic screen

    Science.gov (United States)

    Sayyah, Arash

    Particulate contamination of the optical surfaces of solar collectors, often called "soiling", can have a significant deteriorating impact on energy yield due to the absorption and scattering of incident light. Soiling has more destructive effect on concentrated solar systems than on flat-plate photovoltaic panels, as the former are incapable of converting scattered sunlight. The first part of this thesis deals with the soiling losses of flat-plate photovoltaic (PV), concentrated solar power (CSP), and concentrated photovoltaic (CPV) systems in operation in several regions of the world. Influential parameters in dust accumulation losses, as well as different cleaning mechanisms in pursuit of restoring the efficiency of soiled systems, have been thoroughly investigated. In lieu of the most commonly-practiced manual cleaning method of using high-pressure water jets, the concept of automatic dust removal using the electrostatic forces of electrodynamic screen (EDS) technology is in a developmental stage and on its way toward commercialization. This thesis provides comprehensive analytical solutions for the electric potential and electric field distribution in EDS devices having different configurations. Numerical simulations developed using finite element analysis (FEA) software have corroborated the analytical solutions which can easily be embedded into software programs for particle trajectory simulations while also providing flexibility and generality in the study on the effect of different parameters of the EDS on the electric field and ensuing dust-removal performance. Evaluation and comparison of different repelling and attracting forces exerted on dust particles is of utmost importance to a detailed analysis of EDS performance in dust removal. Hence, the balance of electrostatic and adhesion forces, including van der Waals and capillary forces, have received significant attention in this dissertation. Furthermore, different numerical analyses have been

  18. Concentrator photovoltaic module architectures with capabilities for capture and conversion of full global solar radiation.

    Science.gov (United States)

    Lee, Kyu-Tae; Yao, Yuan; He, Junwen; Fisher, Brent; Sheng, Xing; Lumb, Matthew; Xu, Lu; Anderson, Mikayla A; Scheiman, David; Han, Seungyong; Kang, Yongseon; Gumus, Abdurrahman; Bahabry, Rabab R; Lee, Jung Woo; Paik, Ungyu; Bronstein, Noah D; Alivisatos, A Paul; Meitl, Matthew; Burroughs, Scott; Hussain, Muhammad Mustafa; Lee, Jeong Chul; Nuzzo, Ralph G; Rogers, John A

    2016-12-20

    Emerging classes of concentrator photovoltaic (CPV) modules reach efficiencies that are far greater than those of even the highest performance flat-plate PV technologies, with architectures that have the potential to provide the lowest cost of energy in locations with high direct normal irradiance (DNI). A disadvantage is their inability to effectively use diffuse sunlight, thereby constraining widespread geographic deployment and limiting performance even under the most favorable DNI conditions. This study introduces a module design that integrates capabilities in flat-plate PV directly with the most sophisticated CPV technologies, for capture of both direct and diffuse sunlight, thereby achieving efficiency in PV conversion of the global solar radiation. Specific examples of this scheme exploit commodity silicon (Si) cells integrated with two different CPV module designs, where they capture light that is not efficiently directed by the concentrator optics onto large-scale arrays of miniature multijunction (MJ) solar cells that use advanced III-V semiconductor technologies. In this CPV + scheme ("+" denotes the addition of diffuse collector), the Si and MJ cells operate independently on indirect and direct solar radiation, respectively. On-sun experimental studies of CPV + modules at latitudes of 35.9886° N (Durham, NC), 40.1125° N (Bondville, IL), and 38.9072° N (Washington, DC) show improvements in absolute module efficiencies of between 1.02% and 8.45% over values obtained using otherwise similar CPV modules, depending on weather conditions. These concepts have the potential to expand the geographic reach and improve the cost-effectiveness of the highest efficiency forms of PV power generation.

  19. Concentrator photovoltaic module architectures with capabilities for capture and conversion of full global solar radiation

    Science.gov (United States)

    Lee, Kyu-Tae; Yao, Yuan; He, Junwen; Fisher, Brent; Sheng, Xing; Lumb, Matthew; Xu, Lu; Anderson, Mikayla A.; Scheiman, David; Han, Seungyong; Kang, Yongseon; Gumus, Abdurrahman; Bahabry, Rabab R.; Lee, Jung Woo; Paik, Ungyu; Bronstein, Noah D.; Alivisatos, A. Paul; Meitl, Matthew; Burroughs, Scott; Mustafa Hussain, Muhammad; Lee, Jeong Chul; Nuzzo, Ralph G.; Rogers, John A.

    2016-12-01

    Emerging classes of concentrator photovoltaic (CPV) modules reach efficiencies that are far greater than those of even the highest performance flat-plate PV technologies, with architectures that have the potential to provide the lowest cost of energy in locations with high direct normal irradiance (DNI). A disadvantage is their inability to effectively use diffuse sunlight, thereby constraining widespread geographic deployment and limiting performance even under the most favorable DNI conditions. This study introduces a module design that integrates capabilities in flat-plate PV directly with the most sophisticated CPV technologies, for capture of both direct and diffuse sunlight, thereby achieving efficiency in PV conversion of the global solar radiation. Specific examples of this scheme exploit commodity silicon (Si) cells integrated with two different CPV module designs, where they capture light that is not efficiently directed by the concentrator optics onto large-scale arrays of miniature multijunction (MJ) solar cells that use advanced III-V semiconductor technologies. In this CPV+ scheme (“+” denotes the addition of diffuse collector), the Si and MJ cells operate independently on indirect and direct solar radiation, respectively. On-sun experimental studies of CPV+ modules at latitudes of 35.9886° N (Durham, NC), 40.1125° N (Bondville, IL), and 38.9072° N (Washington, DC) show improvements in absolute module efficiencies of between 1.02% and 8.45% over values obtained using otherwise similar CPV modules, depending on weather conditions. These concepts have the potential to expand the geographic reach and improve the cost-effectiveness of the highest efficiency forms of PV power generation.

  20. Development of a shingle-type solar cell module

    Science.gov (United States)

    Shepard, N. F., Jr.; Sanchez, L. E.

    1978-01-01

    The development of a solar cell module, which is suitable for use in place of shingles on the sloping roofs of residental or commercial buildings, is reported. The design consists of nineteen series-connected 53 mm diameter solar cells arranged in a closely packed hexagon configuration. The shingle solar cell module consists of two basic functional parts: an exposed rigid portion which contains the solar cell assembly, and a semi-flexible portion which is overlapped by the higher courses of the roof installation. Consideration is given to the semi-flexible substrate configuration and solar cell and module-to-module interconnectors. The results of an electrical performance analysis are given and it is noted that high specific power output can be attributed to the efficient packing of the circular cells within the hexagon shape. The shingle should function for at least 15 years, with a specific power output of 98 W/sq w.

  1. Device Performance Improvement of Recycling Double-Pass Cross-Corrugated Solar Air Collectors

    Directory of Open Access Journals (Sweden)

    Chii-Dong Ho

    2018-02-01

    Full Text Available The device performance of cross-corrugated double-pass solar air heaters under external recycle conditions was investigated experimentally and theoretically, and solved numerically using the Newton method. Comparisons were made and represented graphically among three different configurations of the single-pass, flat-plate double-pass and cross-corrugated double-pass devices. Air flowing simultaneously over the wavelike corrugated absorbing plate and in-between both wavelike cross-corrugated absorbing and transverse bottom plates was conducted under double-pass operations. A considerable heat-transfer efficiency enhancement is obtained employing such a recycling double pass device with welding cross-corrugated absorbing plates, instead of using the flat-plate device. An effective thermal performance was achieved because the heat transfer area is doubled and the turbulent intensity is enhanced as well. The power consumption increment owing to the reduction in the cross-sectional area was taken into account associated with the heat-transfer efficiency enhancement for comparisons in determining the optimal design on an economic consideration for the recycling cross-corrugated double-pass device.

  2. Long-term weathering effects on the thermal performance of the Libbey-Owens-Ford (liquid) solar collector

    Science.gov (United States)

    1979-01-01

    Thermal performance tests were conducted on the Libbey-Owens-Ford liquid collector, following long term exposure to natural weathering conditions. Visual inspection of the collector, prior to the retest, indicated noticeable clouding of the inner cover glass, probably resulting from outgassing of the insulation. The absorber plate also showed some discoloration. The test results indicated that performance degradation had occurred at inlet temperatures significantly above ambient. The change in the slope of the efficiency curve, from the original data, is a direct indicator of an increase in the collector heat loss coefficient.

  3. Solar Rotational Modulations of Spectral Irradiance and Correlations with the Variability of Total Solar Irradiance

    Science.gov (United States)

    Lee, Jae N.; Cahalan, Robert F.; Wu, Dong L.

    2016-01-01

    Aims: We characterize the solar rotational modulations of spectral solar irradiance (SSI) and compare them with the corresponding changes of total solar irradiance (TSI). Solar rotational modulations of TSI and SSI at wavelengths between 120 and 1600 nm are identified over one hundred Carrington rotational cycles during 2003-2013. Methods: The SORCE (Solar Radiation and Climate Experiment) and TIMED (Thermosphere Ionosphere Mesosphere Energetics and Dynamics)/SEE (Solar EUV Experiment) measured and SATIRE-S modeled solar irradiances are analyzed using the EEMD (Ensemble Empirical Mode Decomposition) method to determine the phase and amplitude of 27-day solar rotational variation in TSI and SSI. Results: The mode decomposition clearly identifies 27-day solar rotational variations in SSI between 120 and 1600 nm, and there is a robust wavelength dependence in the phase of the rotational mode relative to that of TSI. The rotational modes of visible (VIS) and near infrared (NIR) are in phase with the mode of TSI, but the phase of the rotational mode of ultraviolet (UV) exhibits differences from that of TSI. While it is questionable that the VIS to NIR portion of the solar spectrum has yet been observed with sufficient accuracy and precision to determine the 11-year solar cycle variations, the temporal variations over one hundred cycles of 27-day solar rotation, independent of the two solar cycles in which they are embedded, show distinct solar rotational modulations at each wavelength.

  4. Solar rotational modulations of spectral irradiance and correlations with the variability of total solar irradiance

    Directory of Open Access Journals (Sweden)

    Lee Jae N.

    2016-01-01

    Full Text Available Aims: We characterize the solar rotational modulations of spectral solar irradiance (SSI and compare them with the corresponding changes of total solar irradiance (TSI. Solar rotational modulations of TSI and SSI at wavelengths between 120 and 1600 nm are identified over one hundred Carrington rotational cycles during 2003–2013. Methods: The SORCE (Solar Radiation and Climate Experiment and TIMED (Thermosphere Ionosphere Mesosphere Energetics and Dynamics/SEE (Solar EUV Experiment measured and SATIRE-S modeled solar irradiances are analyzed using the EEMD (Ensemble Empirical Mode Decomposition method to determine the phase and amplitude of 27-day solar rotational variation in TSI and SSI. Results: The mode decomposition clearly identifies 27-day solar rotational variations in SSI between 120 and 1600 nm, and there is a robust wavelength dependence in the phase of the rotational mode relative to that of TSI. The rotational modes of visible (VIS and near infrared (NIR are in phase with the mode of TSI, but the phase of the rotational mode of ultraviolet (UV exhibits differences from that of TSI. While it is questionable that the VIS to NIR portion of the solar spectrum has yet been observed with sufficient accuracy and precision to determine the 11-year solar cycle variations, the temporal variations over one hundred cycles of 27-day solar rotation, independent of the two solar cycles in which they are embedded, show distinct solar rotational modulations at each wavelength.

  5. Comparing between predicted output temperature of flat-plate solar collector and experimental results: computational fluid dynamics and artificial neural network

    Directory of Open Access Journals (Sweden)

    F Nadi

    2017-05-01

    Full Text Available Introduction The significant of solar energy as a renewable energy source, clean and without damage to the environment, for the production of electricity and heat is of great importance. Furthermore, due to the oil crisis as well as reducing the cost of home heating by 70%, solar energy in the past two decades has been a favorite of many researchers. Solar collectors are devices for collecting solar radiant energy through which this energy is converted into heat and then heat is transferred to a fluid (usually air or water. Therefore, a key component in performance improvement of solar heating system is a solar collector optimization under different testing conditions. However, estimation of output parameters under different testing conditions is costly, time consuming and mostly impossible. As a result, smart use of neural networks as well as CFD (computational fluid dynamics to predict the properties with which desired output would have been acquired is valuable. To the best of our knowledge, there are no any studies that compare experimental results with CFD and ANN. Materials and Methods A corrugated galvanized iron sheet of 2 m length, 1 m wide and 0.5 mm in thickness was used as an absorber plate for absorbing the incident solar radiation (Fig. 1 and 2. Corrugations in absorber were caused turbulent air and improved heat transfer coefficient. Computational fluid dynamics K-ε turbulence model was used for simulation. The following assumptions are made in the analysis. (1 Air is a continuous medium and incompressible. (2 The flow is steady and possesses have turbulent flow characteristics, due to the high velocity of flow. (3 The thermal-physical properties of the absorber sheet and the absorber tube are constant with respect to the operating temperature. (4 The bottom side of the absorber tube and the absorber plate are assumed to be adiabatic. Artificial neural network In this research a one-hidden-layer feed-forward network based on the

  6. Solar Power Augmented Electrolysis Module for Energy Storage Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Regenerative fuel cell systems often include a dedicated electrolysis module with solar photovoltaic (PV) panels packaged as a subsystem of the larger energy storage...

  7. Solar cell junction temperature measurement of PV module

    KAUST Repository

    Huang, B.J.

    2011-02-01

    The present study develops a simple non-destructive method to measure the solar cell junction temperature of PV module. The PV module was put in the environmental chamber with precise temperature control to keep the solar PV module as well as the cell junction in thermal equilibrium with the chamber. The open-circuit voltage of PV module Voc is then measured using a short pulse of solar irradiation provided by a solar simulator. Repeating the measurements at different environment temperature (40-80°C) and solar irradiation S (200-1000W/m2), the correlation between the open-circuit voltage Voc, the junction temperature Tj, and solar irradiation S is derived.The fundamental correlation of the PV module is utilized for on-site monitoring of solar cell junction temperature using the measured Voc and S at a short time instant with open circuit. The junction temperature Tj is then determined using the measured S and Voc through the fundamental correlation. The outdoor test results show that the junction temperature measured using the present method, Tjo, is more accurate. The maximum error using the average surface temperature Tave as the junction temperature is 4.8 °C underestimation; while the maximum error using the present method is 1.3 °C underestimation. © 2010 Elsevier Ltd.

  8. Utility Interfaced Pulse-Width Modulation of Solar Fed Voltage ...

    African Journals Online (AJOL)

    This paper describes a utility interfaced pulse-width modulation of solar-fed voltage source single phase full bridge inverter. The proposed system has to do with the conversion of solar energy into electrical energy; boosting the dc power; inversion of the dc to ac and then synchronization of the inverter output with the utility, ...

  9. Optical design of two-axes parabolic trough collector and two-section Fresnel lens for line-to-spot solar concentration.

    Science.gov (United States)

    Ramírez, Carlos; León, Noel; García, Héctor; Aguayo, Humberto

    2015-06-01

    Solar tracking concentrators are optical systems that collect the solar energy flux either in a line or spot using reflective or refractive surfaces. The main problem with these surfaces is their manufacturing complexity, especially at large scales. In this paper, a line-to-spot solar tracking concentrator is proposed. Its configuration allows for a low-cost solar concentrator system. It consists of a parabolic trough collector (PTC) and a two-section PMMA Fresnel lens (FL), both mounted on a two-axis solar tracker. The function of the PTC is to reflect the incoming solar radiation toward a line. Then, the FL, which is placed near the focus, transforms this line into a spot by refraction. It was found that the system can achieve a concentration ratio of 100x and concentrate an average solar irradiance of 518.857W/m2 with an average transmittance of 0.855, taking into account the effect of the chromatic aberration.

  10. Modification of circuit module of dye-sensitized solar cells (DSSC) for solar windows applications

    Science.gov (United States)

    Hastuti, S. D.; Nurosyid, F.; Supriyanto, A.; Suryana, R.

    2016-11-01

    This research has been conducted to obtain a modification of circuit producing the best efficiency of solar window modules as an alternative energy for daily usage. Solar window module was constructed by DSSC cells. In the previous research, solar window was created by a single cell of DSSC. Because it had small size, it could not be applied in the manufacture of solar window. Fabrication of solar window required a larger size of DSSC cell. Therefore, in the next research, a module of solar window was fabricated by connecting few cells of DSSC. It was done by using external electrical circuit method which was modified in the formation of series circuit and parallel circuit. Its fabrication used six cells of DSSC with the size of each cell was 1 cm × 9 cm. DSSC cells were sandwich structures constructed by an active layer of TiO2 as the working electrode, electrolyte solution, dye, and carbon layer. Characterization of module was started one by one, from one cell, two cells, three cells, until six cells of a module. It was conducted to recognize the increasing efficiency value as the larger surface area given. The efficiency of solar window module with series circuit was 0.06%, while using parallel circuit was 0.006%. Module with series circuit generated the higher voltage as the larger surface area. Meanwhile, module through parallel circuit tended to produce the constant voltage as the larger surface area. It was caused by the influence of resistance within the cable in each module. Module with circuit parallel used a longer cable than module with series circuit, so that its resistance increased. Therefore, module with parallel circuit generated voltage that tended to be constant and resulted small efficiency compared to the module with series circuit. It could be concluded that series external circuit was the best modification which could produce the higher efficiency.

  11. Phase 0: goal study for the technical and economic evaluation of the Compound Parabolic Concentrator (CPC) concept applied to solar thermal and photovoltaic collectors. Final report

    Energy Technology Data Exchange (ETDEWEB)

    None

    1975-06-01

    This report presents the results of a quick, six-week technical and economic evaluation of the compound parabolic concentrator (CPC) solar collector. The purpose of this effort was to provide an initial phase of a goals study that is directed toward recommending relative priorities for development of the compound parabolic concentrator concept. The findings of this study are of a very preliminary nature. Conclusions based on study findings at this depth should be considered preliminary and subject to revision and review in later phases.

  12. Thermal analysis and performance optimization of a solar water heater flat plate collector: Application to Tetouan (Morocco)

    International Nuclear Information System (INIS)

    Dagdougui, Hanane; Ouammi, Ahmed; Robba, Michela; Sacile, Roberto

    2011-01-01

    The development of sustainable energy services like the supply of heating water may face a trade-off with a comfortable quality of life, especially in the winter season where suitable strategies to deliver an effective service are required. This paper investigates the heat transfer process as well as the thermal behavior of a flat plate collector evaluating different cover configurations. This investigation is performed according to a two-folded approach. Firstly, a complete model is formulated and implemented taking into account various modes of heat transfer in the collector. The goal is to investigate the impact of the number and types of covers on the top heat loss and the related thermal performance in order to support decision makers about the most cost-effective design. The proposed model can also be used to investigate the effect of the different parameters which may affect the performance of the collector. Secondly, a two objective constrained optimization model has been formulated and implemented to evaluate the optimality of different design approaches. The goal is to support decision makers in the definition of the optimal water flow and of the optimal collector flat area in order to give a good compromise between the collector efficiency and the output water temperature. The overall methodology has been tested on environmental data (temperature and irradiation) which are characteristic of Tetouan (Morocco). (author)

  13. Quantifying Solar Cell Cracks in Photovoltaic Modules by Electroluminescence Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Spataru, Sergiu; Hacke, Peter; Sera, Dezso; Glick, Stephen; Kerekes, Tamas; Teodorescu, Remus

    2015-06-14

    This article proposes a method for quantifying the percentage of partially and totally disconnected solar cell cracks by analyzing electroluminescence images of the photovoltaic module taken under high- and low-current forward bias. The method is based on the analysis of the module's electroluminescence intensity distribution, applied at module and cell level. These concepts are demonstrated on a crystalline silicon photovoltaic module that was subjected to several rounds of mechanical loading and humidity-freeze cycling, causing increasing levels of solar cell cracks. The proposed method can be used as a diagnostic tool to rate cell damage or quality of modules after transportation. Moreover, the method can be automated and used in quality control for module manufacturers, installers, or as a diagnostic tool by plant operators and diagnostic service providers.

  14. MINERGIE modules: heat pump - heat pump/solar - wood - wood/solar; Minergie-Module Waermepumpe - Waermepumpe/Solar - Holz - Holz/Solar

    Energy Technology Data Exchange (ETDEWEB)

    Gallati, J. [Seecon GmbH, Lucerne (Switzerland); Portmann, M. [Buero Markus Portmann, Kriens (Switzerland); Zurfluh, B. [Zurfluh Lottenbach, Lucerne (Switzerland)

    2005-07-01

    This research report for the Swiss Federal Office of Energy (SFOE) presents the results of a project that examined the feasibility of setting up 'MINERGIE' low-energy-consumption module standards for the production of heat in small residential buildings. The aims of the standards and the basic idea behind the MINERGIE-modules are discussed. The concepts of the modules for heat pumps and wood-fired heating systems and their combination with solar installations are examined, as are their areas of application. The requirements placed on the modules are listed. System concepts, including simple schematics for typical installations, are presented for wood-log, wood-chippings and pellets-fired systems as well as for ground-loop and air-water heat pump systems as well as their solar-aided counterparts. The results of cost-benefit analyses are presented and questions regarding system guarantee and liability are examined.

  15. Adaptive Energy-based Bilinear Control of First-Order 1-D Hyperbolic PDEs: Application to a One-Loop Parabolic Solar Collector Trough

    KAUST Repository

    Mechhoud, Sarra

    2017-12-14

    In this paper, the adaptive bilinear control of a first-order 1-D hyperbolic partial differential equation (PDE) with an unknown time-varying source term is investigated where only boundary measurements are available. By means of boundary injection, the bilinear adaptive law is developed in the Lyapunov approach. It consists of a state observer and an input adaptation law combined with a bilinear control method derived using an energy-like principle. Both global asymptotic practical convergence of the tracking error and input-to-state stability of the system are guaranteed. A potential application of this control strategy is the one-loop solar collector parabolic trough where the solar irradiance is the unknown input (source term) and the flow rate is the control variable. The objective is to drive the boundary temperature at the outlet to track a desired profile. Simulation results are provided to illustrate the performance of the proposed method.

  16. Study on heat collector of the solar system utilizing outdoor air. Experimental results in cases of cold and warm regions; Gaiki donyushiki solar system no shunetsubu ni kansuru kenkyu. Kanreichi to ondanchi ni okeru shunetsu jikken to kosatsu

    Energy Technology Data Exchange (ETDEWEB)

    Komano, S.; Ebara, Y. [OM Solar Association, Shizuoka (Japan); Wada, H. [Wada Building Constructors Co. Ltd., Hokkaido (Japan)

    1996-10-27

    An experiment on heat collection was made in the heat collector of a solar system utilizing outdoor air in cold and warm regions. In this system, outdoor air is heated by the air circulation layer on the roof exposed to solar radiation. The heated air is supplied to the object space for heating and ventilation. In the experiment in a cold region, the heat collection characteristics can be adjusted by putting a baffle plate in the air duct according to the experiment of a glass heat collector. The heat collecting air layer on only the iron roof may leak or freeze in the region subject to coldness or heavy snowfall. Therefore, preheat forms the space of a garret, and the preheat temperature comparatively becomes low. The data in which the heat collection characteristics can be adjusted using only a glass heat collector is required corresponding to the regional situation. In the experiment in a warm region, an experiment was made inclusive of the preheat for which outdoor air is absorbed at the eaves. As a result, the heat collection characteristics of preheat were improved. Moreover, a heat collection temperature of about 60{degree}C was obtained on the heat collection surface including the preheat. 1 ref., 12 figs., 3 tabs.

  17. A new concept of hybrid photovoltaic thermal (PVT) collector with natural circulation

    Science.gov (United States)

    Lu, Longsheng; Wang, Xiaowu; Wang, Shuai; Liu, Xiaokang

    2017-07-01

    Hybrid photovoltaic thermal (PVT) technology refers to the integration of a photovoltaic module into a conventional solar thermal collector. Generally, the traditional design of a PVT collector has solar cells fixed on the top surface of an absorber in a flat-plate solar thermal collector. In this work, we presented a new concept of water-based PVT collector in which solar cells were directly placed on the bottom surface of its glass cover. A dynamic numerical model of this new PVT is developed and validated by experimental tests. With numerical analysis, it is found that at same covering factor, the electricity conversion efficiency of solar cells of the new PVT exceed that of the traditional PVT by nearly 10% while its thermal efficiency is approximately 30% lower than that of the traditional PVT. When the covering factor changes from 0.05 to 1, the thermal efficiency of the new PVT drops nearly 70%. The thermal efficiency of both the new PVT and the traditional PVT rise up as the water mass in tank increases. Meanwhile, the final water temperature in tank of the traditional PVT collector declines more than 17 °C, whereas that of the new PVT declines less than 6 °C, when the water mass increases from 100 to 300 kg.

  18. Solar modulation of Northern Hemisphere winter blocking

    Czech Academy of Sciences Publication Activity Database

    Barriopedro, D.; García-Herrera, R.; Huth, Radan

    2008-01-01

    Roč. 113, D14 (2008), D14118/1-D14118/11 ISSN 0148-0227 R&D Projects: GA AV ČR IAA3042401; GA AV ČR IAA300420805 Grant - others:VALIMOD(ES) REN2002-04558-C04-01 Institutional research plan: CEZ:AV0Z30420517 Keywords : solar activity cycle * atmospheric blocking * climate variability * atmospheric circulation * solar-terrestrial relationships Subject RIV: DG - Athmosphere Sciences, Meteorology Impact factor: 3.147, year: 2008

  19. Development and Testing of Shingle-type Solar Cell Modules

    Science.gov (United States)

    Shepard, N. F., Jr.

    1979-01-01

    The design, development, fabrication and testing of a shingle-type terrestrial solar cell module which produces 98 watts/sq m of exposed module area at 1 kW/sq m insolation and 61 C are reported. These modules make it possible to easily incorporate photovoltaic power generation into the sloping roofs of residential or commercial buildings by simply nailing the modules to the plywood roof sheathing. This design consists of nineteen series-connected 53 mm diameter solar cells arranged in a closely packed hexagon configuration. These cells are individually bonded to the embossed surface of a 3 mm thick thermally tempered hexagon-shaped piece of glass. Polyvinyl butyral is used as the laminating adhesive.

  20. PV modules, using color solar cells, designed for building

    Energy Technology Data Exchange (ETDEWEB)

    Ishikawa, N.; Yamashita, H.; Goda, S. [Daido Hoxan Inc., Chitose, Hokkaido (Japan). Chitose Research Lab.] [and others

    1994-12-31

    The designs and structures of a photovoltaic module to be installed in a curtain wall were examined with the object of sharply reducing PV power generation costs. As for the design, solar cells of different colors were produced and an opinion survey of designers and other construction-related persons was conducted. Renderings based on color solar cells were prepared using computer graphics. In general, the output of cells decreases for colors other than shades of dark blue. However, there is a good possibility that greater importance will be put on design, including color and surface condition, than on output. In this case, the market share may expand and as a result, the cost may drop. As for the structure, various materials that can be used for a building-material-integrated-module were investigated and methods to install PV modules into building materials were examined. Moreover, experimental module samples fitted with stainless steel sheets and aluminum-sash frames were made.

  1. A tool for standardized collector performance calculations including PVT

    DEFF Research Database (Denmark)

    Perers, Bengt; Kovacs, Peter; Olsson, Marcus

    2012-01-01

    A tool for standardized calculation of solar collector performance has been developed in cooperation between SP Technical Research Institute of Sweden, DTU Denmark and SERC Dalarna University. The tool is designed to calculate the annual performance of solar collectors at representative locations...... can be tested and modeled as a thermal collector, when the PV electric part is active with an MPP tracker in operation. The thermal collector parameters from this operation mode are used for the PVT calculations....

  2. Simulation model of a solar collector with a heat capacitance on TRNSYS; TRNSYS wo mochiita netsuyoryo wo motsu heibangata shunetsuki no model ka

    Energy Technology Data Exchange (ETDEWEB)

    Yoshinaga, M. [Nagoya City University, Nagoya (Japan); Okumiya, M. [Nagoya University, Nagoya (Japan)

    1997-11-25

    A flat plate type heat collector considering a heat capacitance was structured; assembled into a solar system simulation program, TRNSYS; correction was made on this model for permeation and absorption rates as a result of incident angles onto the heat collecting surface on which sunlight reaches directly; and effectiveness of the proposed model was verified from comparing the heat collection amount with that of conventional systems and measured values. The heat collection amount decreased when incident angles of insolation are taken into consideration, and the amount approached the measured value in the case of the system with a heat capacitance. Variation in temperature at the heat collector exit decreased when the heat capacitance was taken into account. With the case of having no heat capacitance, heat collecting amount greater than the actually collected amount was calculated for days with great insolation, and less amount was calculate for smaller insolation. However, the value as a whole has become close to the measured value, though slightly greater. A value still closer to the measurements was obtained when the incident angle is considered. As seen in a seven-day average, a model having no heat capacitance and not considering the incident angle had an error from the measured value of 38.6%, while a model having a heat capacitance and considering the incident angle had an error of 9.9%. 5 refs., 7 figs.

  3. Investigation of solar photovoltaic module power output by various models

    International Nuclear Information System (INIS)

    Jakhrani, A.Q.; Othman, A.K.; Rigit, A.R.H.; Baini, R.

    2012-01-01

    This paper aims to investigate the power output of a solar photovoltaic module by various models and to formulate a suitable model for predicting the performance of solar photovoltaic modules. The model was used to correct the configurations of solar photovoltaic systems for sustainable power supply. Different types of models namely the efficiency, power, fill factor and current-voltage characteristic curve models have been reviewed. It was found that the examined models predicted a 40% yield of the rated power in cloudy weather conditions and up to 80% in clear skies. The models performed well in terms of electrical efficiency in cloudy days if the influence of low irradiance were incorporated. Both analytical and numerical methods were employed in the formulation of improved model which gave +- 2% error when compared with the rated power output of solar photovoltaic module. The proposed model is more practical in terms of number of variables used and acceptable performance in humid atmospheres. Therefore, it could be useful for the estimation of power output of the solar photovoltaic systems in Sarawak region. (author)

  4. Sandwich module prototype progress for space solar power

    Science.gov (United States)

    Jaffe, Paul; Hodkin, Jason; Harrington, Forest; Person, Clark; Nurnberger, Michael; Nguyen, Bang; LaCava, Susie; Scheiman, Dave; Stewart, Grant; Han, Andrew; Hettwer, Ethan; Rhoades, Daniel

    2014-02-01

    Space solar power (SSP) has been broadly defined as the collection of solar energy in space and its wireless transmission for use on earth. This approach potentially gives the benefit of provision of baseload power while avoiding the losses due to the day/night cycle and tropospheric effects that are associated with terrestrial solar power. Proponents have contended that the implementation of such systems could offer energy security, environmental, and technological advantages to those who would undertake their development. Among recent implementations commonly proposed for SSP, the modular symmetrical concentrator (MSC) and other modular concepts have received considerable attention. Each employs an array of modules for performing conversion of concentrated sunlight into microwaves or laser beams for transmission to earth. While prototypes of such modules have been designed and developed previously by several groups, none have been subjected to the challenging conditions inherent to the space environment and the possible solar concentration levels in which an array of modules might be required to operate. The research described herein details our team's efforts in the development of photovoltaic arrays, power electronics, microwave conversion electronics, and antennas for microwave-based "sandwich" module prototypes. The implementation status and testing results of the prototypes are reviewed.

  5. Quantifying Solar Cell Cracks in Photovoltaic Modules by Electroluminescence Imaging

    DEFF Research Database (Denmark)

    Spataru, Sergiu; Hacke, Peter; Sera, Dezso

    2015-01-01

    This article proposes a method for quantifying the percentage of partially and totally disconnected solar cell cracks by analyzing electroluminescence images of the photovoltaic module taken under high- and low-current forward bias. The method is based on the analysis of the module’s electrolumin...

  6. No-contact method of determining average working-surface temperature of plate-type radiation-absorbing thermal exchange panels of flat solar collectors for heating heat-transfer fluid

    International Nuclear Information System (INIS)

    Avezova, N.R.; Avezov, R.R.

    2015-01-01

    A brand new no-contact method of determining the average working-surface temperature of plate-type radiation-absorbing thermal exchange panels (RATEPs) of flat solar collectors (FSCs) for heating a heat-transfer fluid (HTF) is suggested on the basis of the results of thermal tests in full-scale quasistationary conditions. (authors)

  7. Irreversibility analysis of non isothermal flat plate solar collectors for air heating with a dimensionless model; Analisis de las irreversibilidades en colectores solares de placas planas no isotermicos para calentamiento de aire utilizando un modelo adimensional

    Energy Technology Data Exchange (ETDEWEB)

    Bracamonte-Baran, Johane Hans; Baritto-Loreto, Miguel Leonardo [Universidad Central de Venezuela (Venezuela)]. E-mails: johanehb@gmail.com; johane.bracamonte@ucv.ve; miguel.baritto@ucv.ve

    2013-04-15

    The dimensionless model developed and validated by Baritto and Bracamonte (2012) for the thermal behavior of flat plate solar collector without glass cover is improved by adding the entropy balance equation in a dimensionless form. The model is solved for a wide range of aspect ratios and mass flow numbers. A parametric study is developed and the distribution of internal irreversibilities along the collector is analyzed. The influence of the design parameters on the entropy generation by fluid friction and heat transfer is analyzed and it is found that for certain combinations of these parameters optimal thermodynamic operation can be achieved. [Spanish] En el presente trabajo, el modelo adimensional desarrollado y validado por Baritto y Bracamonte (2012) para describir el comportamiento termico de colectores solares de placas planas sin cubierta transparente, se complementa con la ecuacion adimensional de balance de entropia para un elemento diferencial de colector solar. El modelo se resuelve para un amplio rango de valores de relaciones de aspecto y numero de flujo de masa. A partir de los resultados del modelo se desarrolla un analisis detallado de la influencia de estos parametros sobre la distribucion de irreversibilidades internas a lo largo del colector. Adicionalmente se estudia la influencia de estos parametros sobre los numeros de generacion de entropia por friccion viscosa, por transferencia de calor y total. Se encuentra que existen combinaciones de los parametros antes mencionados, para los cuales, la operacion del colector es termodinamicamente optima para numeros de flujo de masa elevados.

  8. Simulation model for assessing the efficiency of a combined power installation based on a geothermal heat pump and a vacuum solar collector

    Science.gov (United States)

    Vaysman, Ya I.; Surkov, AA; Surkova, Yu I.; Kychkin, AV

    2017-06-01

    The article is devoted to the use of renewable energy sources and the assessment of the feasibility of their use in the climatic conditions of the Western Urals. A simulation model that calculates the efficiency of a combined power installations (CPI) was (RES) developed. The CPI consists of the geothermal heat pump (GHP) and the vacuum solar collector (VCS) and is based on the research model. This model allows solving a wide range of problems in the field of energy and resource efficiency, and can be applied to other objects using RES. Based on the research recommendations for optimizing the management and the application of CPI were given. The optimization system will give a positive effect in the energy and resource consumption of low-rise residential buildings projects.

  9. Solar active envelope module with an adjustable transmittance/absorptance

    Directory of Open Access Journals (Sweden)

    C. Villasante Villasante

    2015-06-01

    Full Text Available A solar active envelope module with a high flexibility degree is proposed in this paper. The transparent module controls the day-lighting of the room, improving the indoor environment, while absorbing the superfluous solar energy inside. That energy is used to increase the efficiency of heating, ventilation, and the air-conditioning (HVAC system of the building. This is carried out through a fine control of the absorptance of the envelope module. The active envelope module consists of three glazed chambers with advanced coatings and frames to assure a minimum thermal transmittance while allowing transparency. A fluid containing heat-absorbing nanoparticles flows inside the central chamber and is heated up due to the impinging solar energy. Unlike other systems proposed in the past, which included transparency control systems based on complex filters and chemical processes, the absorption of the module is controlled by the variation of the thickness of the central chamber with a mechanical device. That is, varying the thickness of the central chamber, it allows controlling the absorptance of the whole system and, as a result, indoor day-lighting and thermal loads. Therefore, a new system is proposed that enables to:  

  10. Transparent electrode requirements for thin film solar cell modules

    KAUST Repository

    Rowell, Michael W.

    2011-01-01

    The transparent conductor (TC) layer in thin film solar cell modules has a significant impact on the power conversion efficiency. Reflection, absorption, resistive losses and lost active area either from the scribed interconnect region in monolithically integrated modules or from the shadow losses of a metal grid in standard modules typically reduce the efficiency by 10-25%. Here, we perform calculations to show that a competitive TC must have a transparency of at least 90% at a sheet resistance of less than 10 Ω/sq (conductivity/absorptivity ≥ 1 Ω -1) for monolithically integrated modules. For standard modules, losses are much lower and the performance of alternative lower cost TC materials may already be sufficient to replace conducting oxides in this geometry. © 2011 The Royal Society of Chemistry.

  11. Photothermal response of CVD synthesized carbon (nanospheres/aqueous nanofluids for potential application in direct solar absorption collectors: a preliminary investigation

    Directory of Open Access Journals (Sweden)

    Poinern GE

    2012-07-01

    Full Text Available Gérrard Eddy Jai Poinern,1 Sridevi Brundavanam,1 Monaliben Shah,1 Iafeta Laava,2 Derek Fawcett11Murdoch Applied Nanotechnology Research Group, 2Department of Physics, Energy Studies and Nanotechnology, Murdoch University, Perth, AustraliaAbstract: Direct-absorption solar collectors have the potential to offer an unlimited source of renewable energy with minimal environmental impact. Unfortunately, their performance is limited by the absorption efficiency of the working fluid. Nanoparticles of functionalized carbon nanospheres (CNS have the potential to improve the photothermal properties of the working fluid. CNS are produced by the pyrolysis of acetylene gas in a tube-based electric furnace/chemical vapor deposition apparatus. The reaction takes place at 1000°C in the presence of nitrogen gas without the use of a catalyst. The synthesized CNS were examined and characterized using field-emission scanning electron microscopy, transmission electron microscopy, X-ray diffraction spectroscopy, Raman spectroscopy, thermal gravimetric analysis, and ultraviolet-visible analysis. The CNS powders with a mean particle size of 210 nm were then functionalized using tetraethylammonium hydroxide ([C2H5]4 N[OH] and used to produce a series of aqueous nanofluids with varying mass content. The photothermal response of both the nanofluids and films composed of CNS were investigated under 1000 W/m2 solar irradiation.Keywords: solar absorption, carbon nanospheres, nanofluids, photothermal

  12. Foldable Frame Supporting Electromagnetic Radiation Collectors

    DEFF Research Database (Denmark)

    2011-01-01

    The present invention relates to flexible frames supporting electromagnetic radiation collectors, such as antennas, antenna reflectors, deflectors or solar collectors, for celestial or terrestrial applications, which can be folded to be stored and/or transported. The method for stowing deforms...

  13. Efficient colored silicon solar modules using integrated resonant dielectric nanoscatterers

    Science.gov (United States)

    Neder, Verena; Luxembourg, Stefan L.; Polman, Albert

    2017-08-01

    We demonstrate photovoltaic modules with a bright green color based on silicon heterojunction solar cells integrated with arrays of light scattering dielectric nanoscatterers. Dense arrays of crystalline silicon nanocylinders, 100-120 nm wide, 240 nm tall, and 325 nm pitch, are made onto module cover slides using substrate-conformal soft-imprint lithography. Strong electric and magnetic dipolar Mie resonances with a narrow linewidth (Q ˜ 30) cause strong (35%-40%) specular light scattering on resonance (˜540 nm). The green color is observed over a wide range of angles (8°-75°). As the resonant nanoscatterers are transparent for the major fraction of the incident solar spectrum, the relative loss in short-circuit current is only 10%-11%. The soft-imprinted nanopatterns can be applied on full-size solar modules and integrated with conventional module encapsulation. The dielectric Mie resonances can be controlled by geometry, opening up a road for designing efficient colorful or white building-integrated photovoltaics.

  14. A concentrator module of spherical Si solar cell

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Zhengxin; Masuda, Atsushi; Nagai, Takehiko; Kondo, Michio [Research Center for Photovoltaics, National Institute of Advanced Industrial Science and Technology (AIST), Central 2, 1-1-1 Umezono, Tsukuba, Ibaraki 305-8568 (Japan); Miyazaki, Takashi; Takano, Miwako; Takano, Masahiro; Yoshigahara, Haruyuki [Techno Frontier Tsukuba, Japan Gore-Tex Inc., 5-5 Tokodai, Tsukuba, Ibaraki 300-2635 (Japan); Sakai, Kazutoshi; Asai, Koichi [Fuji Machine Manufacture Co. Ltd., 480 Tojiri, Hasama, Toyota, Aichi 470-0452 (Japan)

    2007-11-23

    Spherical Si solar cell, which is made up of Si spheres with a diameter of approximately 1.0 mm, is expected to be a promising candidate for low consumption of Si feedstock and simple process technology. This paper describes the formation process and the structure of a concentrator module in detail. The concentrator lens was formed by casting with ultraviolet light hardening resin. The concentration ratio was 4.4 times and the pitch between the spheres was 2.0 mm. By this module design, it was possible to realize a consumption of the Si feedstock of about 3.0 g/W. Conversion efficiencies of 11.3% from single-sphere cell, 8.5% from a 23-spheres module and 5.2% from a 105-spheres module under AM1.5, 100 mW/cm{sup 2} illumination were achieved. (author)

  15. A Long Term Test of Differently Designed Evacuated Tubular Collectors

    DEFF Research Database (Denmark)

    Fan, Jianhua; Dragsted, Janne; Furbo, Simon

    2008-01-01

    During three years seven differently designed evacuated tubular collectors (ETCs) utilizing solar radiation from all directions have been investigated experimentally. The evacuated tubular solar collectors investigated include one SLL all-glass ETC from Tshinghua Solar Co. Ltd, four heat pipe ETCs...

  16. Optimization and performance of bifacial solar modules: A global perspective

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Xingshu; Khan, Mohammad Ryyan; Deline, Chris; Alam, Muhammad Ashraful

    2018-02-01

    With the rapidly growing interest in bifacial photovoltaics (PV), a worldwide map of their potential performance can help assess and accelerate the global deployment of this emerging technology. However, the existing literature only highlights optimized bifacial PV for a few geographic locations or develops worldwide performance maps for very specific configurations, such as the vertical installation. It is still difficult to translate these location- and configuration-specific conclusions to a general optimized performance of this technology. In this paper, we present a global study and optimization of bifacial solar modules using a rigorous and comprehensive modeling framework. Our results demonstrate that with a low albedo of 0.25, the bifacial gain of ground-mounted bifacial modules is less than 10% worldwide. However, increasing the albedo to 0.5 and elevating modules 1 m above the ground can boost the bifacial gain to 30%. Moreover, we derive a set of empirical design rules, which optimize bifacial solar modules across the world and provide the groundwork for rapid assessment of the location-specific performance. We find that ground-mounted, vertical, east-west-facing bifacial modules will outperform their south-north-facing, optimally tilted counterparts by up to 15% below the latitude of 30 degrees, for an albedo of 0.5. The relative energy output is reversed in latitudes above 30 degrees. A detailed and systematic comparison with data from Asia, Africa, Europe, and North America validates the model presented in this paper.

  17. A practical field study of performances of solar modules at various positions in Serbia

    Directory of Open Access Journals (Sweden)

    Pantić Lana S.

    2015-01-01

    Full Text Available In this paper, results of practical field study of performances of three identical monocrystalline solar modules, single power of 60 W, with different inclinations (horizontal, optimally inclined oriented toward South and vertically oriented toward South in real meteorological conditions, in Nis, Serbia, in 2013, are presented. On the basis of the measurement results of solar energy intensity and electrical power generated with solar modules, efficiency (η, Performance Ratio (PR and fill factor (FF were calculated. In 2013, optimally inclined solar module generated 62.8 kWh, horizontal solar module 58.1 kWh and vertical solar module 43.9 kWh of electrical energy. It was found that annually the vertical solar module had the highest value of efficiency (10.9%, then horizontal solar module (10.6% and finally, optimally inclined solar module (10.2%. Annually, the vertical solar module had the highest value of Performance Ratio (0.93, then follows horizontal solar module (0.91 and finally, optimally inclined solar module (0.86. Annually, the horizontal solar module had the highest value of Fill Factor (67.7, then follows vertical solar module (66.6 and, finally, optimally inclined solar module (63.3. It was found that embodied energy payback time (EEPBT for a horizontal, optimally inclined and vertical BIPV system of 1020Wp would be 11.8, 10.9 and 15.6 years, respectively. The results obtained by this study could be used in planning and constructing building-integrated photovoltaics (BIPV, in Serbia. [Projekat Ministarstva nauke Republike Srbije, br. TR 33009

  18. Modelling of cloudless solar radiation for PV module performance analysis

    International Nuclear Information System (INIS)

    Dusabe, D.; Munda, J.; Jimoh, A.

    2009-01-01

    The empirical model developed in this study uses standard specifications together with actual solar radiation and cell temperature to predict voltage-current characteristics of a photovoltaic panel under varying weather conditions. The paper focuses on the modelling of hourly cloudless solar radiation to provide the insolation on a PV module of any orientation, located at any site. The model is built in MATLAB/Simulink environment to provide a tool that may be loaded in the library. It is found that the predicted solar radiation strongly agrees with the experimental data from the National Renewable Energy Laboratory (NREL). Further, a satisfactory agreement between the predicted voltage - current curves and laboratory measurements is obtained. (authors)

  19. The Thermal Collector With Varied Glass Covers

    International Nuclear Information System (INIS)

    Luminosu, I.; Pop, N.

    2010-01-01

    The thermal collector with varied glass covers represents an innovation realized in order to build a collector able to reach the desired temperature by collecting the solar radiation from the smallest surface, with the highest efficiency. In the case of the thermal collector with variable cover glasses, the number of the glass plates covering the absorber increases together with the length of the circulation pipe for the working fluid. The thermal collector with varied glass covers compared to the conventional collector better meet user requirements because: for the same temperature increase, has the collecting area smaller; for the same collection area, realizes the highest temperature increase and has the highest efficiency. This works is addressed to researchers in the solar energy and to engineers responsible with air-conditioning systems design or industrial and agricultural products drying.

  20. Second Generation Novel High Temperature Commercial Receiver & Low Cost High Performance Mirror Collector for Parabolic Solar Trough

    Energy Technology Data Exchange (ETDEWEB)

    Stettenheim, Joel [Norwich Technologies, White River Junction, VT (United States)

    2016-02-29

    Norwich Technologies (NT) is developing a disruptively superior solar field for trough concentrating solar power (CSP). Troughs are the leading CSP technology (85% of installed capacity), being highly deployable and similar to photovoltaic (PV) systems for siting. NT has developed the SunTrap receiver, a disruptive alternative to vacuum-tube concentrating solar power (CSP) receivers, a market currently dominated by the Schott PTR-70. The SunTrap receiver will (1) operate at higher temperature (T) by using an insulated, recessed radiation-collection system to overcome the energy losses that plague vacuum-tube receivers at high T, (2) decrease acquisition costs via simpler structure, and (3) dramatically increase reliability by eliminating vacuum. It offers comparable optical efficiency with thermal loss reduction from ≥ 26% (at presently standard T) to ≥ 55% (at high T), lower acquisition costs, and near-zero O&M costs.