  1. Immersion technique in soft tissue radiography of the hands

    International Nuclear Information System (INIS)

    Maekelae, P.; Haaslahti, J.O.

    1978-01-01

    Soft tissue radiography of hands using the technique of mammary radiography and immersion in a 2.5 cm layer of 1 : 1 water-ethanol solution is evaluated. Using immersion the average background density decreases with a factor of about 2.5 : 1, with little deterioration in resolution (MTF). The immersion procedure makes the demonstration and evaluation of soft tisse swelling and periarticular oedema easier. (Auth.)

  2. The value of immersion hand radiography in soft tissue changes of musculoskeletal disorders

    International Nuclear Information System (INIS)

    Ngo, C.; Yaghmai, I.

    1988-01-01

    Immersion hand radiographs were performed on 25 patients with various clinical presentations and compared to plain radiographic studies of the hands. The immersion technique is superior in outlining the skin, subcutaneous fat layers, and fat layers between muscle planes. More important, this technique highlights the tendons and soft tissue components of the joint, which are hardly seen on standard hand radiographs. Immersion studies are therefore useful, both in the early diagnosis of erosive arthritis and in the follow-up of the course of the disease. They are recommended as an adjunct to conventional hand radiography in musculoskeletal disorders with soft tissue involvement. (orig.)

  3. Imaging of musculoskeletal soft tissue infections

    Energy Technology Data Exchange (ETDEWEB)

    Turecki, Marcin B.; Taljanovic, Mihra S.; Holden, Dean A.; Hunter, Tim B.; Rogers, Lee F. [University of Arizona HSC, Department of Radiology, Tucson, AZ (United States); Stubbs, Alana Y. [Southern Arizona VA Health Care System, Department of Radiology, Tucson, AZ (United States); Graham, Anna R. [University of Arizona HSC, Department of Pathology, Tucson, AZ (United States)

    2010-10-15

    Prompt and appropriate imaging work-up of the various musculoskeletal soft tissue infections aids early diagnosis and treatment and decreases the risk of complications resulting from misdiagnosis or delayed diagnosis. The signs and symptoms of musculoskeletal soft tissue infections can be nonspecific, making it clinically difficult to distinguish between disease processes and the extent of disease. Magnetic resonance imaging (MRI) is the imaging modality of choice in the evaluation of soft tissue infections. Computed tomography (CT), ultrasound, radiography and nuclear medicine studies are considered ancillary. This manuscript illustrates representative images of superficial and deep soft tissue infections such as infectious cellulitis, superficial and deep fasciitis, including the necrotizing fasciitis, pyomyositis/soft tissue abscess, septic bursitis and tenosynovitis on different imaging modalities, with emphasis on MRI. Typical histopathologic findings of soft tissue infections are also presented. The imaging approach described in the manuscript is based on relevant literature and authors' personal experience and everyday practice. (orig.)

  4. Imaging of musculoskeletal soft tissue infections

    International Nuclear Information System (INIS)

    Turecki, Marcin B.; Taljanovic, Mihra S.; Holden, Dean A.; Hunter, Tim B.; Rogers, Lee F.; Stubbs, Alana Y.; Graham, Anna R.

    2010-01-01

    Prompt and appropriate imaging work-up of the various musculoskeletal soft tissue infections aids early diagnosis and treatment and decreases the risk of complications resulting from misdiagnosis or delayed diagnosis. The signs and symptoms of musculoskeletal soft tissue infections can be nonspecific, making it clinically difficult to distinguish between disease processes and the extent of disease. Magnetic resonance imaging (MRI) is the imaging modality of choice in the evaluation of soft tissue infections. Computed tomography (CT), ultrasound, radiography and nuclear medicine studies are considered ancillary. This manuscript illustrates representative images of superficial and deep soft tissue infections such as infectious cellulitis, superficial and deep fasciitis, including the necrotizing fasciitis, pyomyositis/soft tissue abscess, septic bursitis and tenosynovitis on different imaging modalities, with emphasis on MRI. Typical histopathologic findings of soft tissue infections are also presented. The imaging approach described in the manuscript is based on relevant literature and authors' personal experience and everyday practice. (orig.)

  5. Diagnostic imaging of the equine tarsal region using radiography and ultrasonography. Part 1: the soft tissues.

    Science.gov (United States)

    Vanderperren, Katrien; Raes, Els; Hoegaerts, Michel; Saunders, Jimmy H

    2009-02-01

    The equine tarsus is the most commonly affected hindlimb region associated with lameness. Diagnostic imaging is routinely applied but because of its complexity, being composed of 10 multifaceted bones and different joints, multiple ligaments, tendons and bursae, imaging this region can be a challenge. This is the first part of a two-part review of the structures and disorders of the equine tarsus. It describes the principal disorders affecting the soft tissues of the tarsal region and addresses some of the technical aspects in taking radiographic, ultrasonographic and scintigraphic images of the different soft tissue lesions. Where applicable, comments on the diagnostic use of contrast radiography, arthroscopy and tenoscopy are made. In current clinical practice a combination of radiography and ultrasonography is still most frequently used to arrive at a diagnosis.

  6. Diagnostic imaging of the equine fetlock region using radiography and ultrasonography. Part 1: Soft tissues.

    Science.gov (United States)

    Vanderperren, Katrien; Saunders, Jimmy H

    2009-08-01

    The equine fetlock is the joint most commonly associated with lameness. Although the fetlock is regarded as a simple joint, diagnosis of a fetlock disorder can be a challenge and various imaging modalities are routinely used to arrive at an accurate diagnosis. This review describes the principal disorders affecting the soft tissues of the fetlock region and addresses some of the technical aspects involved in taking radiographic and ultrasonographic images of the different soft tissue lesions. A combination of radiography and ultrasonography is still the most commonly used diagnostic approach in clinical practice.

  7. Soft Tissue Biomechanical Modeling for Computer Assisted Surgery

    CERN Document Server

    2012-01-01

      This volume focuses on the biomechanical modeling of biological tissues in the context of Computer Assisted Surgery (CAS). More specifically, deformable soft tissues are addressed since they are the subject of the most recent developments in this field. The pioneering works on this CAS topic date from the 1980's, with applications in orthopaedics and biomechanical models of bones. More recently, however, biomechanical models of soft tissues have been proposed since most of the human body is made of soft organs that can be deformed by the surgical gesture. Such models are much more complicated to handle since the tissues can be subject to large deformations (non-linear geometrical framework) as well as complex stress/strain relationships (non-linear mechanical framework). Part 1 of the volume presents biomechanical models that have been developed in a CAS context and used during surgery. This is particularly new since most of the soft tissues models already proposed concern Computer Assisted Planning, with ...

  8. Radiographic and ultrasonographic imaging of soft tissue disorders of the equine carpus

    International Nuclear Information System (INIS)

    Dik, K.J.

    1990-01-01

    Common soft tissue disorders of the equine carpus are fluctuating or firm soft tissue swellings, wounds and draining tracts. Survey radiography may show the size, position and origin of the swellings and reveals soft tissue calcification, accumulation of air and radiopaque foreign material. Contrast radiography enables accurate visualization of the size, shape, position and origin of fluctuating soft tissue swellings, demonstrates abnormal intersynovial communication and allows precise demonstration of the extent of puncture wounds and draining tracts. Ultrasonography allows differentiation between a firm solid or thick-walled cystic lesion, clearly reveals injuries to tendons, muscle and ligaments, reveals minor irregularities of the wall and the lumen of distended tendon sheaths and may demonstrate radiolucent foreign material more clearly than contrast radiography

  9. Finding-specific display presets for computed radiography soft-copy reading.

    Science.gov (United States)

    Andriole, K P; Gould, R G; Webb, W R

    1999-05-01

    Much work has been done to optimize the display of cross-sectional modality imaging examinations for soft-copy reading (i.e., window/level tissue presets, and format presentations such as tile and stack modes, four-on-one, nine-on-one, etc). Less attention has been paid to the display of digital forms of the conventional projection x-ray. The purpose of this study is to assess the utility of providing presets for computed radiography (CR) soft-copy display, based not on the window/level settings, but on processing applied to the image optimized for visualization of specific findings, pathologies, etc (i.e., pneumothorax, tumor, tube location). It is felt that digital display of CR images based on finding-specific processing presets has the potential to: speed reading of digital projection x-ray examinations on soft copy; improve diagnostic efficacy; standardize display across examination type, clinical scenario, important key findings, and significant negatives; facilitate image comparison; and improve confidence in and acceptance of soft-copy reading. Clinical chest images are acquired using an Agfa-Gevaert (Mortsel, Belgium) ADC 70 CR scanner and Fuji (Stamford, CT) 9000 and AC2 CR scanners. Those demonstrating pertinent findings are transferred over the clinical picture archiving and communications system (PACS) network to a research image processing station (Agfa PS5000), where the optimal image-processing settings per finding, pathologic category, etc, are developed in conjunction with a thoracic radiologist, by manipulating the multiscale image contrast amplification (Agfa MUSICA) algorithm parameters. Soft-copy display of images processed with finding-specific settings are compared with the standard default image presentation for 50 cases of each category. Comparison is scored using a 5-point scale with the positive scale denoting the standard presentation is preferred over the finding-specific processing, the negative scale denoting the finding

  10. Radiologic diagnosis of malignant soft-tissue tumors of the extremities

    International Nuclear Information System (INIS)

    Peters, P.E.; Friedmann, G.

    1983-01-01

    In malignant soft-tissue tumors of the extremities the radiologist is asked to define size and extent of the lesion and it's relationship to adjacent structures. The assessment of the nature of the lesion is of utmost importance, however, the contribution of the different imaging modalities varies considerably. In a review article the current roles of conventional radiography, xeroradiography, real-time ultrasonography, computed tomography and arteriography in the diagnostic workup of malignant soft-tissue tumors of the extremities are discussed. The statements made are based upon own comparative studies as well as on a review of the literature. In the assessment of the nature of a soft-tissue mass the contribution of all radiologic imaging methods is rather limited, although arteriography may add valuable information if performed complementary to CT. Real-time ultrasonography is well suited to define size, location and extent of peripheral soft-tissue masses. It is therefore recommended as the first imaging method and for follow-up studies. Equivocal findings by real-time sonography and new cases for treatment planning must be confirmed by computed tomography which proved to be the most reliable and the best reproducible imaging method for soft-tissue tumors of the extremities. (orig.)

  11. Validation of a Radiography-Based Quantification Designed to Longitudinally Monitor Soft Tissue Calcification in Skeletal Muscle.

    Science.gov (United States)

    Moore, Stephanie N; Hawley, Gregory D; Smith, Emily N; Mignemi, Nicholas A; Ihejirika, Rivka C; Yuasa, Masato; Cates, Justin M M; Liu, Xulei; Schoenecker, Jonathan G

    2016-01-01

    Soft tissue calcification, including both dystrophic calcification and heterotopic ossification, may occur following injury. These lesions have variable fates as they are either resorbed or persist. Persistent soft tissue calcification may result in chronic inflammation and/or loss of function of that soft tissue. The molecular mechanisms that result in the development and maturation of calcifications are uncertain. As a result, directed therapies that prevent or resorb soft tissue calcifications remain largely unsuccessful. Animal models of post-traumatic soft tissue calcification that allow for cost-effective, serial analysis of an individual animal over time are necessary to derive and test novel therapies. We have determined that a cardiotoxin-induced injury of the muscles in the posterior compartment of the lower extremity represents a useful model in which soft tissue calcification develops remote from adjacent bones, thereby allowing for serial analysis by plain radiography. The purpose of the study was to design and validate a method for quantifying soft tissue calcifications in mice longitudinally using plain radiographic techniques and an ordinal scoring system. Muscle injury was induced by injecting cardiotoxin into the posterior compartment of the lower extremity in mice susceptible to developing soft tissue calcification. Seven days following injury, radiographs were obtained under anesthesia. Multiple researchers applied methods designed to standardize post-image processing of digital radiographs (N = 4) and quantify soft tissue calcification (N = 6) in these images using an ordinal scoring system. Inter- and intra-observer agreement for both post-image processing and the scoring system used was assessed using weighted kappa statistics. Soft tissue calcification quantifications by the ordinal scale were compared to mineral volume measurements (threshold 450.7mgHA/cm3) determined by μCT. Finally, sample-size calculations necessary to discriminate

  12. Osteotomy simulation and soft tissue prediction using computer tomography scans

    International Nuclear Information System (INIS)

    Teschner, M.; Girod, S.; Girod, B.

    1999-01-01

    In this paper, a system is presented that can be used to simulate osteotomies of the skull and to estimate the resulting of tissue changes. Thus, the three-dimensional, photorealistic, postoperative appearance of a patient can be assessed. The system is based on a computer tomography scan and a photorealistic laser scan of the patient's face. In order to predict the postoperative appearance of a patient the soft tissue must follow the movement of the underlying bone. In this paper, a multi-layer soft tissue model is proposed that is based on springs. It incorporates features like skin turgor, gravity and sliding bone contact. The prediction of soft tissue changes due to bone realignments is computed using a very efficient and robust optimization method. The system can handle individual patient data sets and has been tested with several clinical cases. (author)

  13. Automatic method for selective enhancement of different tissue densities at digital chest radiography

    International Nuclear Information System (INIS)

    McNitt-Gray, M.F.; Taira, R.K.; Eldredge, S.L.; Razavi, M.

    1991-01-01

    This paper reports that digital chest radiographs often are too bright and/or lack contrast when viewed on a video display. The authors have developed a method that can automatically provide a series of look-up tables that selectively enhance the radiographically soft or dense tissues on a digital chest radiograph. This reduces viewer interaction and improves displayed image quality. On the basis of a histogram analysis, gray-level ranges are approximated for the patient background, radiographically soft tissues, and radiographically dense tissues. A series of look-up tables is automatically created by varying the contrast in each range to achieve a level of enhancement for a selected tissue range. This is repeated for differing amounts of enhancement and for each tissue range. This allows the viewer to interactively select a tissue density range and degree of enhancement at the time of display via precalculated look-up tables. Preclinical trials in pediatric radiology using computed radiography images show that this method reduces viewer interaction and improves or maintains the displayed image quality

  14. 'pre-erosive' radiologic signs of rheumatoid arthritis in soft tissue radiography of the hands

    Energy Technology Data Exchange (ETDEWEB)

    Maekelae, P; Virtama, P [Turku Univ. (Finland). Dept. of Diagnostic Radiology

    1978-01-01

    Soft tissue radiography of the hands using the mammographic immersion technique was performed on 119 patients, having definite or classical rheumatoid arthritis, and on 123 controls of matching age, sex, and professional distribution. A total of 7744 finger joints and carpal borders were investigated for joint swelling, periarticular edema, pre-erosive and erosive bone changes, joint space narrowing, and osteoarthritic joint margin spurs. Slight joint swelling and pre-erosive bone changes were found in connection with osteoarthritic joint changes in elderly control patients. Periarticular edema and moderate to massive joint swelling were quite reliable signs for synovitis. The incidence of pre-erosive bone signs was significantly greater in the rheumatoid arthritis group than in the control group, especially in patients less than 60 years old. These signs can be regarded as suggestive of rheumatoid arthritis; probability diagnosis could be performed using these signs and the Bayesian approach.

  15. Immersion radiography for enhancement of soft tissue contrast - experimental study and clinical application -

    International Nuclear Information System (INIS)

    Lee, Kyung Soo; Kang, Heung Sik; Kim, Chu Wan

    1986-01-01

    Detection and evaluation of early soft tissue changes are important in rheumatoid arthritis or other joint diseases. The most important factors for radiologic demonstration of soft tissue changes are resolving power and the optimization of contrast differences between structures representing skin and subcutaneous tissue densities. Phantom study was done by using combination of immersion technique and mammography to get the most reliable method for improvement of soft tissue contrast without deterioration of resolution. Clinical application was also done in 5 normal volunteers and 5 rheumatoid patients. The results indicate that soft tissue contrast, especially between skin and subcutaneous tissues can be significantly improved with combination of immersion technique and mammography with 50% ethanol in both phantom and clinical study.

  16. Measurement of facial soft tissues thickness using 3D computed tomographic images

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Ho Gul; Kim, Kee Deog; Shin, Dong Won; Hu, Kyung Seok; Lee, Jae Bum; Park, Hyok; Park, Chang Seo [Yonsei Univ. Hospital, Seoul (Korea, Republic of); Han, Seung Ho [Catholic Univ. of Korea, Seoul (Korea, Republic of)

    2006-03-15

    To evaluate accuracy and reliability of program to measure facial soft tissue thickness using 3D computed tomographic images by comparing with direct measurement. One cadaver was scanned with a Helical CT with 3 mm slice thickness and 3 mm/sec table speed. The acquired data was reconstructed with 1.5 mm reconstruction interval and the images were transferred to a personal computer. The facial soft tissue thickness were measured using a program developed newly in 3D image. For direct measurement, the cadaver was cut with a bone cutter and then a ruler was placed above the cut side. The procedure was followed by taking pictures of the facial soft tissues with a high-resolution digital camera. Then the measurements were done in the photographic images and repeated for ten times. A repeated measure analysis of variance was adopted to compare and analyze the measurements resulting from the two different methods. Comparison according to the areas was analyzed by Mann-Whitney test. There were no statistically significant differences between the direct measurements and those using the 3D images(p>0.05). There were statistical differences in the measurements on 17 points but all the points except 2 points showed a mean difference of 0.5 mm or less. The developed software program to measure the facial soft tissue thickness using 3D images was so accurate that it allows to measure facial soft tissue thickness more easily in forensic science and anthropology.

  17. Measurement of facial soft tissues thickness using 3D computed tomographic images

    International Nuclear Information System (INIS)

    Jeong, Ho Gul; Kim, Kee Deog; Shin, Dong Won; Hu, Kyung Seok; Lee, Jae Bum; Park, Hyok; Park, Chang Seo; Han, Seung Ho

    2006-01-01

    To evaluate accuracy and reliability of program to measure facial soft tissue thickness using 3D computed tomographic images by comparing with direct measurement. One cadaver was scanned with a Helical CT with 3 mm slice thickness and 3 mm/sec table speed. The acquired data was reconstructed with 1.5 mm reconstruction interval and the images were transferred to a personal computer. The facial soft tissue thickness were measured using a program developed newly in 3D image. For direct measurement, the cadaver was cut with a bone cutter and then a ruler was placed above the cut side. The procedure was followed by taking pictures of the facial soft tissues with a high-resolution digital camera. Then the measurements were done in the photographic images and repeated for ten times. A repeated measure analysis of variance was adopted to compare and analyze the measurements resulting from the two different methods. Comparison according to the areas was analyzed by Mann-Whitney test. There were no statistically significant differences between the direct measurements and those using the 3D images(p>0.05). There were statistical differences in the measurements on 17 points but all the points except 2 points showed a mean difference of 0.5 mm or less. The developed software program to measure the facial soft tissue thickness using 3D images was so accurate that it allows to measure facial soft tissue thickness more easily in forensic science and anthropology

  18. Soft tissue tumors - imaging methods

    International Nuclear Information System (INIS)

    Arlart, I.P.

    1985-01-01

    Soft Tissue Tumors - Imaging Methods: Imaging methods play an important diagnostic role in soft tissue tumors concerning a preoperative evaluation of localization, size, topographic relationship, dignity, and metastatic disease. The present paper gives an overview about diagnostic methods available today such as ultrasound, thermography, roentgenographic plain films and xeroradiography, radionuclide methods, computed tomography, lymphography, angiography, and magnetic resonance imaging. Besides sonography particularly computed tomography has the most important diagnostic value in soft tissue tumors. The application of a recently developed method, the magnetic resonance imaging, cannot yet be assessed in its significance. (orig.) [de

  19. A comparison of radiography, computed tomography, and magnetic resonance imaging for the diagnosis of palmar process fractures in foals

    International Nuclear Information System (INIS)

    Kaneps, A.J.; Koblik, P.D.; Freeman, D.M.; Pool, R.R.; O'Brien, T.R.

    1995-01-01

    The relative sensitivity of radiography, computed tomography, and magnetic resonance imaging for detecting palmar process fractures of the distal phalanx in foals was determined and the imaging findings were compared with histomorphologic evaluations of the palmar processes. Compared to radiography, computed tomography and magnetic resonance imaging did not improve the sensitivity for detection of palmar process fractures. Statistical agreement for palmar process fracture diagnosis was excellent among the three imaging modalities. Histomorphologic evaluations were more sensitive for diagnosis of palmar process fracture than any of the imaging modalities. Three-dimensional image reconstructions and volume measurements of distal phalanges and palmar process fracture fragments from computed tomography studies provided more complete anatomical information than radiography. Magnetic resonance imaging confirmed that the deep digital flexor tendon insertion on the distal phalanx is immediately axial to the site where palmar process fractures occur, and differentiated cartilage, bone, and soft tissue structures of the hoof

  20. Computer radiography - indirect digital radiography

    International Nuclear Information System (INIS)

    Jezierski, G.

    2008-01-01

    Implementation of the new European standards for industrial radiography with the use of storage phosphor imaging plates will result in the arousing of interest among numerous laboratories in non-destructive testing with application of the new method of testing to replace conventional radiography used so far, i.e. film radiography. Computer radiography is quite commonly used for medical radiography, where the fundamental problem consists in reduction of the radiation dose during the examination of a patient. However, it must be kept in mind that industrial applications have a little bit different requirements when compared with medical radiography. The article describes only new method for radiographic testing. (author)

  1. Computational Modeling for Enhancing Soft Tissue Image Guided Surgery: An Application in Neurosurgery.

    Science.gov (United States)

    Miga, Michael I

    2016-01-01

    With the recent advances in computing, the opportunities to translate computational models to more integrated roles in patient treatment are expanding at an exciting rate. One area of considerable development has been directed towards correcting soft tissue deformation within image guided neurosurgery applications. This review captures the efforts that have been undertaken towards enhancing neuronavigation by the integration of soft tissue biomechanical models, imaging and sensing technologies, and algorithmic developments. In addition, the review speaks to the evolving role of modeling frameworks within surgery and concludes with some future directions beyond neurosurgical applications.

  2. Computed tomography in soft-tissue lesions of the hand and forearm

    International Nuclear Information System (INIS)

    Schmitt, R.; Warmuth-Metz, M.; Lucas, D.; Feyerabend, T.; Schindler, G.; Lanz, U.

    1990-01-01

    Computed tomography was carried out in 32 patients with clinically equivocal soft-tissue lesions of the hand (24 times) and forearm (8 times). The CT scans were performed with the patients in standard positions; thin slices and zoom technique were used. All soft-tissue tumors were correctly diagnosed with regard to localization, size and infiltration of the surrounding tissue. The histological diagnosis was correct in tendon-sheath proliferations, deposits caused by metabolic disorders, epithelial and ganglion cysts, hemangiomas, lipomas and in one schwannoma. A malignancy was suspected and was proven to be correct in two cases. False-positive diagnoses of a malignant soft-tissue tumor were made in one case of an aggressive fibromatosis, in a rapidly progressive, ossifying myositis, and three times in the presence of postoperative scar tissue following the resection of a sarcoma. Finally, a case of proliferative myositis regarded as semimalignant was underrated by CT. The hand surgeon considered CT diagnostics to be very helpful in planning operations in an anatomically complex organ such as the hand. (orig.) [de

  3. The 'pre-erosive' radiologic signs of rheumatoid arthritis in soft tissue radiography of the hands

    International Nuclear Information System (INIS)

    Maekelae, P.; Virtama, P.

    1978-01-01

    Soft tissue radiography of the hands using the mammographic immersion technique was performed on 119 patients, having definite or classical rheumatoid arthritis, and on 123 controls of matching age, sex, and professional distribution. A total of 7744 finger joints and carpal borders were investigated for joint swelling, periarticular edema, pre-erosive and erosive bone changes, joint space narrowing, and osteoarthritic joint margin spurs. Slight joint swelling and pre-erosive bone changes were found in connection with osteoarthritic joint changes in elderly control patients. Periarticular edema and moderate to massive joint swelling were quite reliable signs for synovitis. The incidence of pre-erosive bone signs was significantly greater in the rheumatoid arthritis group than in the control group, especially in patients less than 60 years old. These signs can be regarded as suggestive of rheumatoid arthritis; probability diagnosis could be performed using these signs and the Bayesian approach. (orig.) [de

  4. Clinical usefulness of facial soft tissues thickness measurement using 3D computed tomographic images

    International Nuclear Information System (INIS)

    Jeong, Ho Gul; Kim, Kee Deog; Hu, Kyung Seok; Lee, Jae Bum; Park, Hyok; Han, Seung Ho; Choi, Seong Ho; Kim, Chong Kwan; Park, Chang Seo

    2006-01-01

    To evaluate clinical usefulness of facial soft tissue thickness measurement using 3D computed tomographic images. One cadaver that had sound facial soft tissues was chosen for the study. The cadaver was scanned with a Helical CT under following scanning protocols about slice thickness and table speed: 3 mm and 3 mm/sec, 5 mm and 5 mm/sec, 7 mm and 7 mm/sec. The acquired data were reconstructed 1.5, 2.5, 3.5 mm reconstruction interval respectively and the images were transferred to a personal computer. Using a program developed to measure facial soft tissue thickness in 3D image, the facial soft tissue thickness was measured. After the ten-time repeation of the measurement for ten times, repeated measure analysis of variance (ANOVA) was adopted to compare and analyze the measurements using the three scanning protocols. Comparison according to the areas was analysed by Mann-Whitney test. There were no statistically significant intraobserver differences in the measurements of the facial soft tissue thickness using the three scanning protocols (p>0.05). There were no statistically significant differences between measurements in the 3 mm slice thickness and those in the 5 mm, 7 mm slice thickness (p>0.05). There were statistical differences in the 14 of the total 30 measured points in the 5 mm slice thickness and 22 in the 7 mm slice thickness. The facial soft tissue thickness measurement using 3D images of 7 mm slice thickness is acceptable clinically, but those of 5 mm slice thickness is recommended for the more accurate measurement

  5. Detection of radiographically occult-ankle fractures. Positive predictive value of post-traumatic soft-tissue swelling

    International Nuclear Information System (INIS)

    Kumar, M.; Caruana, E.

    2000-01-01

    The objective of this study was to assess the value of soft-tissue swelling on plain radiographs as a predictor of radiographically occult fracture, after acute ankle injury (trauma). Patients with acute ankle trauma and plain radiographic evidence of soft-tissue swelling were included in this study. Patients were excluded if ankle trauma was sustained more than 48 hours previously or if fracture was visible on plain radiographs. All subjects (n=25) underwent computed tomography (CT) of the ankle in sagittal and coronal planes. Size of soft-tissue swelling was measured from initial Antero-posterior (AP) radiographs. The subjects in the study were placed into two groups according to whether a fracture was identified on CT or not. The results identified that those subjects without a fracture demonstrated by CT, had a soft-tissue swelling of less than 12.6 mm, while those with over 17.1mm swelling, showed a fracture on CT. Twelve patients (48 per cent) had radiographically occult fractures identified with CT. Fracture sites included: Talus/Talar Dome (n=9), posterior or lateral malleolos (n=2), distal tibia/fibula (n=1). CT detected significant soft-tissue injuries in six patients (24 per cent), composed of damaged anterior talo-fibular ligament (n=4), torn flexor tendons (n=1), and damaged fibular calcaneal ligament (n=1). One patient also showed gas in the talar dome. This study concludes that presence of a large soft-tissue swelling on plain radiographs after acute ankle trauma suggests an underlying fracture. A soft-tissue swelling of >15 mm is a reasonable threshold to prompt further imaging. Helical computed tomography provides good visualisation of subtle bone injuries and may detect clinically important soft-tissue injuries. While the study has a small sample, there is clear evidence that there is a trend worth investigating. Future research will seek to investigate a larger sample. Copyright (1999) Australian Institute of Radiography

  6. Comparative study between computed radiography and conventional radiography

    International Nuclear Information System (INIS)

    Noorhazleena Azaman; Khairul Anuar Mohd Salleh; Sapizah Rahim; Shaharudin Sayuti; Arshad Yassin; Abdul Razak Hamzah

    2010-01-01

    In Industrial Radiography, there are many criteria that need to be considered based on established standards to accept or reject the radiographic film. For conventional radiography, we need to consider the optical density by using the densitometer when viewing the film on the viewer. But in the computed radiography (CR) we need to evaluate and performed the analysis from the quality of the digital image through grey value. There are many factors that affected the digital image quality. One of the factors which are affected to the digital image quality in the image processing is grey value that related to the contrast resolution. In this work, we performed grey value study measurement on digital radiography systems and compared it with exposed films in conventional radiography. The test sample is a steel step wedge. We found out the contrast resolution is higher in Computed Radiography compared with Conventional Radiography. (author)

  7. A Computational Modeling Approach for Investigating Soft Tissue Balancing in Bicruciate Retaining Knee Arthroplasty

    Directory of Open Access Journals (Sweden)

    Shahram Amiri

    2012-01-01

    Full Text Available Bicruciate retaining knee arthroplasty, although has shown improved functions and patient satisfaction compared to other designs of total knee replacement, remains a technically demanding option for treating severe cases of arthritic knees. One of the main challenges in bicruciate retaining arthroplasty is proper balancing of the soft tissue during the surgery. In this study biomechanics of soft tissue balancing was investigated using a validated computational model of the knee joint with high fidelity definitions of the soft tissue structures along with a Taguchi method for design of experiments. The model was used to simulate intraoperative balancing of soft tissue structures following the combinations suggested by an orthogonal array design. The results were used to quantify the corresponding effects on the laxity of the joint under anterior-posterior, internal-external, and varus-valgus loads. These effects were ranked for each ligament bundle to identify the components of laxity which were most sensitive to the corresponding surgical modifications. The resulting map of sensitivity for all the ligament bundles determined the components of laxity most suitable for examination during intraoperative balancing of the soft tissue. Ultimately, a sequence for intraoperative soft tissue balancing was suggested for a bicruciate retaining knee arthroplasty.

  8. A Computational Modeling Approach for Investigating Soft Tissue Balancing in Bicruciate Retaining Knee Arthroplasty

    Science.gov (United States)

    Amiri, Shahram; Wilson, David R.

    2012-01-01

    Bicruciate retaining knee arthroplasty, although has shown improved functions and patient satisfaction compared to other designs of total knee replacement, remains a technically demanding option for treating severe cases of arthritic knees. One of the main challenges in bicruciate retaining arthroplasty is proper balancing of the soft tissue during the surgery. In this study biomechanics of soft tissue balancing was investigated using a validated computational model of the knee joint with high fidelity definitions of the soft tissue structures along with a Taguchi method for design of experiments. The model was used to simulate intraoperative balancing of soft tissue structures following the combinations suggested by an orthogonal array design. The results were used to quantify the corresponding effects on the laxity of the joint under anterior-posterior, internal-external, and varus-valgus loads. These effects were ranked for each ligament bundle to identify the components of laxity which were most sensitive to the corresponding surgical modifications. The resulting map of sensitivity for all the ligament bundles determined the components of laxity most suitable for examination during intraoperative balancing of the soft tissue. Ultimately, a sequence for intraoperative soft tissue balancing was suggested for a bicruciate retaining knee arthroplasty. PMID:23082090

  9. Application of direct digital radiography of nasal bone

    International Nuclear Information System (INIS)

    Gao Dengfa; Wang Haijun; Zhang Ailian; Wang Yulin

    2005-01-01

    Objective: To research the application value of direct digital radiograph (DDR ) in nasal bone imaging. Methods: One hundred cases were examined by DDR, 30 cases of them were examined by two methods both DDR and conventional radiography. All digital images were post-processed with 'MUSICA' (Multi-Scale Image Contrast Amplification), incision and largamente, analyzed and diagnosed by experienced two radiologists and two technicians. Results: One hundred cases of nasal bone, soft tissue of nose were showed excellent in DDR, and satisfactory cases were 95 and 92, respectively. Forty-six cases of nasal bone fractures were found. Thirty cases were examined by both DDR and conventional radiography, images of nasal bone, soft tissue of nose were showed, satisfactory cases were 28 in DDR; and satisfactory cases were 6 (χ 2 =20.05, P 2 =15.06, P 2 =5.14, P<0.05) in conventional and digital radiography, respectively. Conclusion: DDR images of nasal bone, soft tissue of nose was excellent, more fractures were discovered than conventional radiography. Image quality of DDR is better than conventional radiography in nasal bone imaging. (authors)

  10. A comparison of digital tomosynthesis and chest radiography in evaluating airway lesions using computed tomography as a reference.

    Science.gov (United States)

    Choo, Ji Yung; Lee, Ki Yeol; Yu, Ami; Kim, Je-Hyeong; Lee, Seung Heon; Choi, Jung Won; Kang, Eun-Young; Oh, Yu Whan

    2016-09-01

    To compare the diagnostic performance of digital tomosynthesis (DTS) and chest radiography for detecting airway abnormalities, using computed tomography (CT) as a reference. We evaluated 161 data sets from 149 patients (91 with and 70 without airway abnormalities) who had undergone radiography, DTS, and CT to detect airway problems. Radiographs and DTS were evaluated to localize and score the severity of the airway abnormalities, and to score the image quality using CT as a reference. Receiver operating characteristics (ROC), McNemar's test, weighted kappa, and the paired t-test were used for statistical analysis. The sensitivity of DTS was higher (reader 1, 93.51 %; reader 2, 94.29 %) than chest radiography (68.83 %; 71.43 %) in detecting airway lesions. The diagnostic accuracy of DTS (90.91 %; 94.70 %) was also significantly better than that of radiography (78.03 %; 82.58 %, all p chest radiography (1.83, 2.74; p < 0.05) in the results of both readers. The inter-observer agreement with respect to DTS findings was moderate and superior when compared to radiography findings. DTS is a more accurate and sensitive modality than radiography for detecting airway lesions that are easily obscured by soft tissue structures in the mediastinum. • Digital tomosynthesis offers new diagnostic options for airway lesions. • Digital tomosynthesis is more sensitive and accurate than radiography for airway lesions. • Digital tomosynthesis shows better image quality than radiography. • Assessment of lesion severity, via tomosynthesis is comparable to computed tomography.

  11. Chest X ray effective doses estimation in computed radiography

    International Nuclear Information System (INIS)

    Abdalla, Esra Abdalrhman Dfaalla

    2013-06-01

    Conventional chest radiography is technically difficult because of wide in tissue attenuations in the chest and limitations of screen-film systems. Computed radiography (CR) offers a different approach utilizing a photostimulable phosphor. photostimulable phosphors overcome some image quality limitations of chest imaging. The objective of this study was to estimate the effective dose in computed radiography at three hospitals in Khartoum. This study has been conducted in radiography departments in three centres Advanced Diagnostic Center, Nilain Diagnostic Center, Modern Diagnostic Center. The entrance surface dose (ESD) measurement was conducted for quality control of x-ray machines and survey of operators experimental techniques. The ESDs were measured by UNFORS dosimeter and mathematical equations to estimate patient doses during chest X rays. A total of 120 patients were examined in three centres, among them 62 were males and 58 were females. The overall mean and range of patient dosed was 0.073±0.037 (0.014-0.16) mGy per procedure while the effective dose was 3.4±01.7 (0.6-7.0) mSv per procedure. This study compared radiation doses to patients radiographic examinations of chest using computed radiology. The radiation dose was measured in three centres in Khartoum- Sudan. The results of the measured effective dose showed that the dose in chest radiography was lower in computed radiography compared to previous studies.(Author)

  12. A virtual surgical training system that simulates cutting of soft tissue using a modified pre-computed elastic model.

    Science.gov (United States)

    Toe, Kyaw Kyar; Huang, Weimin; Yang, Tao; Duan, Yuping; Zhou, Jiayin; Su, Yi; Teo, Soo-Kng; Kumar, Selvaraj Senthil; Lim, Calvin Chi-Wan; Chui, Chee Kong; Chang, Stephen

    2015-08-01

    This work presents a surgical training system that incorporates cutting operation of soft tissue simulated based on a modified pre-computed linear elastic model in the Simulation Open Framework Architecture (SOFA) environment. A precomputed linear elastic model used for the simulation of soft tissue deformation involves computing the compliance matrix a priori based on the topological information of the mesh. While this process may require a few minutes to several hours, based on the number of vertices in the mesh, it needs only to be computed once and allows real-time computation of the subsequent soft tissue deformation. However, as the compliance matrix is based on the initial topology of the mesh, it does not allow any topological changes during simulation, such as cutting or tearing of the mesh. This work proposes a way to modify the pre-computed data by correcting the topological connectivity in the compliance matrix, without re-computing the compliance matrix which is computationally expensive.

  13. A comparison of digital tomosynthesis and chest radiography in evaluating airway lesions using computed tomography as a reference

    International Nuclear Information System (INIS)

    Choo, Ji Yung; Lee, Ki Yeol; Choi, Jung Won; Yu, Ami; Kim, Je-Hyeong; Lee, Seung Heon; Kang, Eun-Young; Oh, Yu Whan

    2016-01-01

    To compare the diagnostic performance of digital tomosynthesis (DTS) and chest radiography for detecting airway abnormalities, using computed tomography (CT) as a reference. We evaluated 161 data sets from 149 patients (91 with and 70 without airway abnormalities) who had undergone radiography, DTS, and CT to detect airway problems. Radiographs and DTS were evaluated to localize and score the severity of the airway abnormalities, and to score the image quality using CT as a reference. Receiver operating characteristics (ROC), McNemar's test, weighted kappa, and the paired t-test were used for statistical analysis. The sensitivity of DTS was higher (reader 1, 93.51 %; reader 2, 94.29 %) than chest radiography (68.83 %; 71.43 %) in detecting airway lesions. The diagnostic accuracy of DTS (90.91 %; 94.70 %) was also significantly better than that of radiography (78.03 %; 82.58 %, all p < 0.05). DTS image quality was significantly better than chest radiography (1.83, 2.74; p < 0.05) in the results of both readers. The inter-observer agreement with respect to DTS findings was moderate and superior when compared to radiography findings. DTS is a more accurate and sensitive modality than radiography for detecting airway lesions that are easily obscured by soft tissue structures in the mediastinum. (orig.)

  14. Multiple-energy tissue-cancellation applications of a digital beam attenuator to chest radiography

    International Nuclear Information System (INIS)

    Dobbins, J.T. III.

    1985-01-01

    The digitally-formed primary beam attenuator (DBA) spatially modulates the x-ray fluence incident upon the patient to selectively attenuate regions of interest. The DBA attenuating mask is constructed from CeO 2 powder by a modified printing technique and uses image information from an initial low-dose exposure. Two tissue-cancellation imaging techniques are investigated with the DBA: (1) energy-dependent information is used to form a beam attenuator that attenuates specific tissues in the primary x-ray beam for tissue-cancelled film radiography; (2) the beam attenuator is used to improve image signal-to-noise and scattered radiation properties in traditional energy-subtraction tissue-cancellation imaging with digital detectors. The tissue-cancellation techniques in the primary x-ray beam were capable of adequately removing either soft-tissue or bone from the final compensated film radiograph when using a phantom with well defined soft-tissue and bone sections. However, when tried on an anthropomorphic chest phantom the results were adequate for cancellation of large soft tissue structures, but unsatisfactory for cancellation of bony structures such as the ribs, because of the limited spatial frequency content of the attenuating mask. The second technique (with digital detectors) showed improved uniformity of image signal-to-noise and a two-fold increase in soft-tissue nodule contrast due to improved scattered radiation properties. The tissue-cancelled images contained residual image contributions from the presence of the attenuating mask, but this residual may be correctable by future algorithms

  15. Material parameter identification and inverse problems in soft tissue biomechanics

    CERN Document Server

    Evans, Sam

    2017-01-01

    The articles in this book review hybrid experimental-computational methods applied to soft tissues which have been developed by worldwide specialists in the field. People developing computational models of soft tissues and organs will find solutions for calibrating the material parameters of their models; people performing tests on soft tissues will learn what to extract from the data and how to use these data for their models and people worried about the complexity of the biomechanical behavior of soft tissues will find relevant approaches to address this complexity.

  16. Computed tomography in facial trauma

    International Nuclear Information System (INIS)

    Zilkha, A.

    1982-01-01

    Computed tomography (CT), plain radiography, and conventional tomography were performed on 30 patients with facial trauma. CT demonstrated bone and soft-tissue involvement. In all cases, CT was superior to tomography in the assessment of facial injury. It is suggested that CT follow plain radiography in the evaluation of facial trauma

  17. Direct digital radiography versus storage phosphor radiography in the detection of wrist fractures

    Energy Technology Data Exchange (ETDEWEB)

    Peer, Siegfried; Neitzel, Ulrich; Giacomuzzi, Salvatore M.; Pechlaner, Sigurd; KUenzel, Karl Heinz; Peer, Regina; Gassner, Eva; Steingruber, Iris; Gaber, O.; Jaschke, Werner

    2002-04-01

    AIM: To define the value of digital radiography with a clinical flat panel detector system for evaluation of wrist fractures in comparison with state of the art storage phosphor radiography. MATERIAL AND METHODS: Hard copy images of 26 fractured wrist specimens were acquired with the same exposure dose on a state of the art storage phosphor radiography system and a clinical flat panel detector. Image features like cortical bone surface, trabecular bone, soft tissues and fracture delineation were independently analysed by 4 observers using a standardised protocol. Image quality ratings were evaluated with an analysis of variance (ANOVA). RESULTS: Flat panel detector radiographs were rated superior with respect to cortical and trabecular bone representation as well as fracture evaluation, while storage phosphor radiographs produced better soft tissue detail. CONCLUSION: In some of the observed image quality aspects, the performance of caesium iodide/amorphous silicon flat panel detector exceeds state of the art storage phosphor radiography. This makes it well suited for skeletal imaging particularly in trauma as seen in the detection of wrist fractures. Peer, S. et al. (2002)

  18. Direct digital radiography versus storage phosphor radiography in the detection of wrist fractures

    International Nuclear Information System (INIS)

    Peer, Siegfried; Neitzel, Ulrich; Giacomuzzi, Salvatore M.; Pechlaner, Sigurd; KUenzel, Karl Heinz; Peer, Regina; Gassner, Eva; Steingruber, Iris; Gaber, O.; Jaschke, Werner

    2002-01-01

    AIM: To define the value of digital radiography with a clinical flat panel detector system for evaluation of wrist fractures in comparison with state of the art storage phosphor radiography. MATERIAL AND METHODS: Hard copy images of 26 fractured wrist specimens were acquired with the same exposure dose on a state of the art storage phosphor radiography system and a clinical flat panel detector. Image features like cortical bone surface, trabecular bone, soft tissues and fracture delineation were independently analysed by 4 observers using a standardised protocol. Image quality ratings were evaluated with an analysis of variance (ANOVA). RESULTS: Flat panel detector radiographs were rated superior with respect to cortical and trabecular bone representation as well as fracture evaluation, while storage phosphor radiographs produced better soft tissue detail. CONCLUSION: In some of the observed image quality aspects, the performance of caesium iodide/amorphous silicon flat panel detector exceeds state of the art storage phosphor radiography. This makes it well suited for skeletal imaging particularly in trauma as seen in the detection of wrist fractures. Peer, S. et al. (2002)

  19. Soft tissue aneurysmal bone cyst

    Energy Technology Data Exchange (ETDEWEB)

    Wang, X.L.; Gielen, J.L.; Delrue, F.; De Schepper, A.M.A. [Department of Radiology, Universitair Ziekenhuis Antwerpen (University of Antwerp), Wilrijkstraat 10, 2650, Edegem (Belgium); Salgado, R. [Department of Pathology, Universitair Ziekenhuis Antwerpen (University of Antwerp), Wilrijkstraat 10, 2650, Edegem (Belgium)

    2004-08-01

    A soft tissue aneurysmal bone cyst located in the right gluteus medius of a 21-year-old man is reported. On conventional radiography, the lesion demonstrated a spherically trabeculated mass with a calcific rim. On CT scan, it showed a well-organized peripheral calcification resembling a myositis ossificans. On MRI, it presented as a multilocular, cystic lesion with fluid-fluid levels. The lesion had no solid components except for intralesional septa. Although findings on imaging and histology were identical to those described in classical aneurysmal bone cyst, diagnosis was delayed because of lack of knowledge of this entity and its resemblance to the more familiar post-traumatic heterotopic ossification (myositis ossificans). (orig.)

  20. Soft tissue aneurysmal bone cyst

    International Nuclear Information System (INIS)

    Wang, X.L.; Gielen, J.L.; Delrue, F.; De Schepper, A.M.A.; Salgado, R.

    2004-01-01

    A soft tissue aneurysmal bone cyst located in the right gluteus medius of a 21-year-old man is reported. On conventional radiography, the lesion demonstrated a spherically trabeculated mass with a calcific rim. On CT scan, it showed a well-organized peripheral calcification resembling a myositis ossificans. On MRI, it presented as a multilocular, cystic lesion with fluid-fluid levels. The lesion had no solid components except for intralesional septa. Although findings on imaging and histology were identical to those described in classical aneurysmal bone cyst, diagnosis was delayed because of lack of knowledge of this entity and its resemblance to the more familiar post-traumatic heterotopic ossification (myositis ossificans). (orig.)

  1. Imaging of tuberculosis. Pt. 5. Peripheral osteoarticular and soft-tissue tuberculosis

    Energy Technology Data Exchange (ETDEWEB)

    Hugosson, C. [Dept. of Radiology, King Faisal Specialist Hospital and Research Centre, Riyadh (Saudi Arabia); Nyman, R.S. [Dept. of Radiology, King Faisal Specialist Hospital and Research Centre, Riyadh (Saudi Arabia); Brismar, J. [Dept. of Radiology, King Faisal Specialist Hospital and Research Centre, Riyadh (Saudi Arabia); Larsson, S.G. [Dept. of Radiology, King Faisal Specialist Hospital and Research Centre, Riyadh (Saudi Arabia); Lindahl, S. [Dept. of Radiology, King Faisal Specialist Hospital and Research Centre, Riyadh (Saudi Arabia); Lundstedt, C. [Dept. of Radiology, King Faisal Specialist Hospital and Research Centre, Riyadh (Saudi Arabia)

    1996-07-01

    Purpose: To assess frequency, location, and appearance of peripheral osteoarticular and soft-tissue tuberculosis (TB). Material and Methods: Twenty-five of 503 patients with TB had peripheral osteoarticular TB and 5 had soft-tissue TB. Chest radiography, CT, and MR imaging were applied. Results: The location of the osteoarticular lesion was articular/epiphyseal in 14 patients, articular/metaphyseal in 3, and metaphyseal without joint involvement in 3. Involvement of flat bone was found in 4 patients (5 lesions). The morphologic appearance was similar to that of a lytic tumour in 9 patients (10 lesions) and that of a destructive joint lesion in 16 patients. The soft-tissue TB in all 5 patients presented as an abscess. Twelve patients had a total of 20 additional sites of involvement: Chest in 9, abdomen in 4, spine in 4, the neck in 3, and the central nervous system in one patient. Conclusion: On the basis of radiologic appearance, it can be difficult to differentiate peripheral osteoarticular and soft-tissue TB from other degenerative, inflammatory, or neoplastic disorders, and the importance of a high awareness is stressed in order to reach an early diagnosis. (orig.).

  2. Imaging of tuberculosis. Pt. 5. Peripheral osteoarticular and soft-tissue tuberculosis

    International Nuclear Information System (INIS)

    Hugosson, C.; Nyman, R.S.; Brismar, J.; Larsson, S.G.; Lindahl, S.; Lundstedt, C.

    1996-01-01

    Purpose: To assess frequency, location, and appearance of peripheral osteoarticular and soft-tissue tuberculosis (TB). Material and Methods: Twenty-five of 503 patients with TB had peripheral osteoarticular TB and 5 had soft-tissue TB. Chest radiography, CT, and MR imaging were applied. Results: The location of the osteoarticular lesion was articular/epiphyseal in 14 patients, articular/metaphyseal in 3, and metaphyseal without joint involvement in 3. Involvement of flat bone was found in 4 patients (5 lesions). The morphologic appearance was similar to that of a lytic tumour in 9 patients (10 lesions) and that of a destructive joint lesion in 16 patients. The soft-tissue TB in all 5 patients presented as an abscess. Twelve patients had a total of 20 additional sites of involvement: Chest in 9, abdomen in 4, spine in 4, the neck in 3, and the central nervous system in one patient. Conclusion: On the basis of radiologic appearance, it can be difficult to differentiate peripheral osteoarticular and soft-tissue TB from other degenerative, inflammatory, or neoplastic disorders, and the importance of a high awareness is stressed in order to reach an early diagnosis. (orig.)

  3. Selenium-based digital radiography of the cervical spine. Comparison with screen-film radiography for the depiction of anatomic details

    International Nuclear Information System (INIS)

    Ludwig, K.; Diederich, S.; Wormanns, D.; Link, T.M.; Lenzen, H.; Heindel, W.

    2002-01-01

    Purpose: To compare selenium-based digital radiography with conventional screen-film radiography of the cervical spine. Materials and Methods: In a prospective study X-ray images of the cervical spine were obtained in 25 patients using selenium-based digital radiography and conventional screen-film radiography. All images were clinically indicated. Selenium-based digital radiography and conventional screen-film radiography were used in a randomized order. Four radiologists independently evaluated all 50 examinations for the visibility of 76 anatomic details according to a five-level confidence scale (1=not visible, 5=very good visibility). From the evaluation of these anatomic details scores for the upper and middle cervical spine, the cervicothoracic junction and the cervical soft tissues were calculated. The scores for selenium-based digital radiography and conventional screen-film radiography were compared using Wilcoxon's signed rank test. Results: From a total of 15,200 observations (608 per patient) the following scores were calculated for selenium-based digital radiography and for screen-film radiography, respectively: Upper cervical spine 3.88 and 3.94; middle cervical spine 4.60 and 4.48; cervico-thoracic junction 3.64 and 2.62; cervical soft tissue 4.47 and 3.46. The differences between the last two scores were statistically significant (p [de

  4. Bilateral, symmetrical soft tissue calcifications in the face

    International Nuclear Information System (INIS)

    Vazquez, Josue; Rosenthal, Daniel I.

    2010-01-01

    A 50-year-old woman with jaw pain and a history of bisphosphonate use was shown on radiography to have ill-defined soft tissue calcifications overlying the maxilla, mandible, and zygomatic bones bilaterally. The bones were normal. CT revealed similar findings. Although a broad imaging differential diagnosis was initially considered, further questioning of the patient revealed a history of facial injections with a calcium hydroxylapatite product for cosmetic purposes. The appearance of this increasingly popular treatment should be recognized to avoid errors in interpretation. (orig.)

  5. Bilateral, symmetrical soft tissue calcifications in the face

    Energy Technology Data Exchange (ETDEWEB)

    Vazquez, Josue; Rosenthal, Daniel I. [Massachusetts General Hospital, Harvard Medical School, Department of Radiology, Boston, MA (United States)

    2010-04-15

    A 50-year-old woman with jaw pain and a history of bisphosphonate use was shown on radiography to have ill-defined soft tissue calcifications overlying the maxilla, mandible, and zygomatic bones bilaterally. The bones were normal. CT revealed similar findings. Although a broad imaging differential diagnosis was initially considered, further questioning of the patient revealed a history of facial injections with a calcium hydroxylapatite product for cosmetic purposes. The appearance of this increasingly popular treatment should be recognized to avoid errors in interpretation. (orig.)

  6. Soft Tissue Sarcoma

    Science.gov (United States)

    ... muscles, tendons, fat, and blood vessels. Soft tissue sarcoma is a cancer of these soft tissues. There ... have certain genetic diseases. Doctors diagnose soft tissue sarcomas with a biopsy. Treatments include surgery to remove ...

  7. Computed tomography of the soft tissues of the shoulder. Pt. 3

    International Nuclear Information System (INIS)

    Dihlmann, W.; Bandick, J.

    1988-01-01

    Computed tomography of the soft tissue of the shoulder in cases of calcifying tendinitis of the rotator cuff provides the following information: 1. Localisation of the calcium deposits within the rotator cuff. 2. Contours and density of the calcium deposits correlated with the clinical findings as described by Uhthoff et al. Ill-defined contours and non-homogeneous deposits are associated with more severe clinical features. 3. Computed tomography shows that apatite particles, which are not visible radiologically, may penetrate into the shoulder joint and produce synovitis with an effusion. This is of importance in local therapy. (orig.) [de

  8. Heavy-ion radiography

    International Nuclear Information System (INIS)

    Fabrikant, J.I.; Tobias, C.A.; Holley, W.R.; Benton, E.V.

    1981-01-01

    Heavy-particle radiography has clinical potential as a newly developed noninvasive low-dose imaging procedure that provides increased resolution of minute density differences in soft tissues of the body. The method utilizes accelerated high-energy ions, primarily carbon and neon, at the Bevalac accelerator at the Lawrence Berkeley Laboratory. The research program for medicine utilizes heavy-ion radiography for low-dose mammography, for treatment planning for cancer patients, and for imaging and accurate densitometry of skeletal structures, brain and spinal neoplasms, and the heart. The potential of heavy-ion imaging, and particularly reconstruction tomography, is now proving to be an adjunct to existing diagnostic imaging procedures in medicine, both for applications to the diagnosis, management and treatment of clinical cancer in man, and for the early detection of small soft-tissue tumors at low radiation dose

  9. Computed radiography in paediatrics

    International Nuclear Information System (INIS)

    Kelly, C.

    1996-01-01

    Computed radiography has also been called storage phosphor technology, digital luminescence radiography and scintillation phosphor technology, since it relies on phosphor imaging plate as an alternative to screen-film. One of the major advantages in the use of computed radiography (CR) is the consistent image quality independence of the radiographer and exposure used. And secondly a marked reduction in the need for repeat films was achieved and thus a decrease in dose to the patient. In some cases, dose was able to be reduced further due to the fact that the plates respond to lower doses and still provide adequate image quality. Digitalising the Cr image allows it to be transmitted to an imaging console. The images can then be stored on optical disc. 7 refs

  10. Necrotizing Soft Tissue Infection

    Directory of Open Access Journals (Sweden)

    Sahil Aggarwal, BS

    2018-04-01

    Full Text Available History of present illness: A 71-year-old woman with a history of metastatic ovarian cancer presented with sudden onset, rapidly progressing painful rash in the genital region and lower abdominal wall. She was febrile to 103°F, heart rate was 114 beats per minute, and respiratory rate was 24 per minute. Her exam was notable for a toxic-appearing female with extensive areas of erythema, tenderness, and induration to her lower abdomen, intertriginous areas, and perineum with intermittent segments of crepitus without hemorrhagic bullae or skin breakdown. Significant findings: Computed tomography (CT of the abdominal and pelvis with intravenous (IV contrast revealed inflammatory changes, including gas and fluid collections within the ventral abdominal wall extending to the vulva, consistent with a necrotizing soft tissue infection. Discussion: Necrotizing fasciitis is a serious infection of the skin and soft tissues that requires an early diagnosis to reduce morbidity and mortality. Classified into several subtypes based on the type of microbial infection, necrotizing fasciitis can rapidly progress to septic shock or death if left untreated.1 Diagnosing necrotizing fasciitis requires a high index of suspicion based on patient risk factors, presentation, and exam findings. Definitive treatment involves prompt surgical exploration and debridement coupled with IV antibiotics.2,3 Clinical characteristics such as swelling, disproportionate pain, erythema, crepitus, and necrotic tissue should be a guide to further diagnostic tests.4 Unfortunately, lab values such as white blood cell count and lactate imaging studies have high sensitivity but low specificity, making the diagnosis of necrotizing fasciitis still largely a clinical one.4,5 CT is a reliable method to exclude the diagnosis of necrotizing soft tissue infections (sensitivity of 100%, but is only moderately reliable in correctly identifying such infections (specificity of 81%.5 Given the emergent

  11. Digital dissection - using contrast-enhanced computed tomography scanning to elucidate hard- and soft-tissue anatomy in the Common Buzzard Buteo buteo.

    Science.gov (United States)

    Lautenschlager, Stephan; Bright, Jen A; Rayfield, Emily J

    2014-04-01

    Gross dissection has a long history as a tool for the study of human or animal soft- and hard-tissue anatomy. However, apart from being a time-consuming and invasive method, dissection is often unsuitable for very small specimens and often cannot capture spatial relationships of the individual soft-tissue structures. The handful of comprehensive studies on avian anatomy using traditional dissection techniques focus nearly exclusively on domestic birds, whereas raptorial birds, and in particular their cranial soft tissues, are essentially absent from the literature. Here, we digitally dissect, identify, and document the soft-tissue anatomy of the Common Buzzard (Buteo buteo) in detail, using the new approach of contrast-enhanced computed tomography using Lugol's iodine. The architecture of different muscle systems (adductor, depressor, ocular, hyoid, neck musculature), neurovascular, and other soft-tissue structures is three-dimensionally visualised and described in unprecedented detail. The three-dimensional model is further presented as an interactive PDF to facilitate the dissemination and accessibility of anatomical data. Due to the digital nature of the data derived from the computed tomography scanning and segmentation processes, these methods hold the potential for further computational analyses beyond descriptive and illustrative proposes. © 2013 The Authors. Journal of Anatomy published by John Wiley & Sons Ltd on behalf of Anatomical Society.

  12. Computed Tomography diagnosis of skeletal involvement in multiple myeloma

    International Nuclear Information System (INIS)

    Scutellari, Pier Nuccio; Galeotti, Roberto; Leprotti, Stefano; Piva, Nadia; Spanedda, Romedio

    1997-01-01

    The authors assess the role of Computed Topography in the diagnosis and management of multiple myeloma (MM) and investigate if Computed Tomography findings can influence the clinical approach, prognosis and treatment. 273 multiple myeloma patients submitted to Computed Tomography June 1994, to December, 1996. The patients were 143 men and 130 women (mean age: 65 years): 143 were stage I, 38 stage II and 92 stage III according to Durie and Salomon's clinical classification. All patients were submitted to blood tests, spinal radiography and Computed Tomography, the latter with serial 5-mm scans on several vertebral bodies. Computed Tomography despicted vertebral arch and process involvement in 3 cases with the vertebral pedicle sign. Moreover, Computed Tomography proved superior to radiography in showing the spread of myelomatous masses into the soft tissues in a case with solitary permeative lesion in the left public bone, which facilitated subsequent biopsy. As for extraosseous localizations, Computed Tomography demonstrated thoracic soft tissue (1 woman) and pelvic (1 man) involvement by myelomtous masses penetrating into surrounding tissues. In our series, only a case of osteosclerotic bone myeloma was observed in the pelvis, associated with lytic abnormalities. Computed Tomography findings do not seem to improve the clinical approach and therapeutic management of the disease. Nevertheless, the authors reccommend Computed Tomography for some myelomatous conditions, namely: a) in the patients with focal bone pain but normal skeletal radiographs; b) in the patients with M protein, bone marrow plasmocytosis and back pain, but with an incoclusive multiple myeloma diagnosis; c) to asses bone spread in the regions which are anatomically complex or difficult to study with radiography and to depict soft tissue involvement; d) for bone biopsy

  13. Damage Models for Soft Tissues: A Survey.

    Science.gov (United States)

    Li, Wenguang

    Damage to soft tissues in the human body has been investigated for applications in healthcare, sports, and biomedical engineering. This paper reviews and classifies damage models for soft tissues to summarize achievements, identify new directions, and facilitate finite element analysis. The main ideas of damage modeling methods are illustrated and interpreted. A few key issues related to damage models, such as experimental data curve-fitting, computational effort, connection between damage and fractures/cracks, damage model applications, and fracture/crack extension simulation, are discussed. Several new challenges in the field are identified and outlined. This review can be useful for developing more advanced damage models and extending damage modeling methods to a variety of soft tissues.

  14. Dual energy radiography using active detector technology

    International Nuclear Information System (INIS)

    Seibert, J.A.; Poage, T.F.; Alvarez, R.E.

    1996-01-01

    A new technology has been implemented using an open-quotes active-detectorclose quotes comprised of two computed radiography (CR) imaging plates in a sandwich geometry for dual-energy radiography. This detector allows excellent energy separation, short exposure time, and high signal to noise ratio (SNR) for clinically robust open-quotes bone-onlyclose quotes and open-quotes soft-tissue onlyclose quotes images with minimum patient motion. Energy separation is achieved by two separate exposures at widely different kVp's: the high energy (120 kVp + 1.5 mm Cu filter) exposure is initiated first, followed by a short burst of intense light to erase the latent image on the front plate, and then a 50 kVp (low energy) exposure. A personal computer interfaced to the x-ray generator, filter wheel, and active detector system orchestrates the acquisition sequence within a time period of 150 msec. The front and back plates are processed using a CR readout algorithm with fixed speed and wide dynamic range. open-quotes Bone-onlyclose quotes and open-quotes soft-tissue onlyclose quotes images are calculated by geometric alignment of the two images and application of dual energy decomposition algorithms on a pixel by pixel basis. Resultant images of a calibration phantom demonstrate an increase of SNR 2 / dose by ∼73 times when compared to a single exposure open-quotes passive-detectorclose quotes comprised of CR imaging plates, and an ∼8 fold increase compared to a screen-film dual-energy cassette comprised of different phosphor compounds. In conclusion, dual energy imaging with open-quotes active detectorclose quotes technology is clinically feasible and can provide substantial improvements over conventional methods for dual-energy radiography

  15. Impact of Computed Tomography Image Quality on Image-Guided Radiation Therapy Based on Soft Tissue Registration

    International Nuclear Information System (INIS)

    Morrow, Natalya V.; Lawton, Colleen A.; Qi, X. Sharon; Li, X. Allen

    2012-01-01

    Purpose: In image-guided radiation therapy (IGRT), different computed tomography (CT) modalities with varying image quality are being used to correct for interfractional variations in patient set-up and anatomy changes, thereby reducing clinical target volume to the planning target volume (CTV-to-PTV) margins. We explore how CT image quality affects patient repositioning and CTV-to-PTV margins in soft tissue registration-based IGRT for prostate cancer patients. Methods and Materials: Four CT-based IGRT modalities used for prostate RT were considered in this study: MV fan beam CT (MVFBCT) (Tomotherapy), MV cone beam CT (MVCBCT) (MVision; Siemens), kV fan beam CT (kVFBCT) (CTVision, Siemens), and kV cone beam CT (kVCBCT) (Synergy; Elekta). Daily shifts were determined by manual registration to achieve the best soft tissue agreement. Effect of image quality on patient repositioning was determined by statistical analysis of daily shifts for 136 patients (34 per modality). Inter- and intraobserver variability of soft tissue registration was evaluated based on the registration of a representative scan for each CT modality with its corresponding planning scan. Results: Superior image quality with the kVFBCT resulted in reduced uncertainty in soft tissue registration during IGRT compared with other image modalities for IGRT. The largest interobserver variations of soft tissue registration were 1.1 mm, 2.5 mm, 2.6 mm, and 3.2 mm for kVFBCT, kVCBCT, MVFBCT, and MVCBCT, respectively. Conclusions: Image quality adversely affects the reproducibility of soft tissue-based registration for IGRT and necessitates a careful consideration of residual uncertainties in determining different CTV-to-PTV margins for IGRT using different image modalities.

  16. Impact of Computed Tomography Image Quality on Image-Guided Radiation Therapy Based on Soft Tissue Registration

    Energy Technology Data Exchange (ETDEWEB)

    Morrow, Natalya V.; Lawton, Colleen A. [Department of Radiation Oncology, Medical College of Wisconsin, Milwaukee, Wisconsin (United States); Qi, X. Sharon [Department of Radiation Oncology, University of Colorado Denver, Denver, Colorado (United States); Li, X. Allen, E-mail: ali@mcw.edu [Department of Radiation Oncology, Medical College of Wisconsin, Milwaukee, Wisconsin (United States)

    2012-04-01

    Purpose: In image-guided radiation therapy (IGRT), different computed tomography (CT) modalities with varying image quality are being used to correct for interfractional variations in patient set-up and anatomy changes, thereby reducing clinical target volume to the planning target volume (CTV-to-PTV) margins. We explore how CT image quality affects patient repositioning and CTV-to-PTV margins in soft tissue registration-based IGRT for prostate cancer patients. Methods and Materials: Four CT-based IGRT modalities used for prostate RT were considered in this study: MV fan beam CT (MVFBCT) (Tomotherapy), MV cone beam CT (MVCBCT) (MVision; Siemens), kV fan beam CT (kVFBCT) (CTVision, Siemens), and kV cone beam CT (kVCBCT) (Synergy; Elekta). Daily shifts were determined by manual registration to achieve the best soft tissue agreement. Effect of image quality on patient repositioning was determined by statistical analysis of daily shifts for 136 patients (34 per modality). Inter- and intraobserver variability of soft tissue registration was evaluated based on the registration of a representative scan for each CT modality with its corresponding planning scan. Results: Superior image quality with the kVFBCT resulted in reduced uncertainty in soft tissue registration during IGRT compared with other image modalities for IGRT. The largest interobserver variations of soft tissue registration were 1.1 mm, 2.5 mm, 2.6 mm, and 3.2 mm for kVFBCT, kVCBCT, MVFBCT, and MVCBCT, respectively. Conclusions: Image quality adversely affects the reproducibility of soft tissue-based registration for IGRT and necessitates a careful consideration of residual uncertainties in determining different CTV-to-PTV margins for IGRT using different image modalities.

  17. Quantification and validation of soft tissue deformation

    DEFF Research Database (Denmark)

    Mosbech, Thomas Hammershaimb; Ersbøll, Bjarne Kjær; Christensen, Lars Bager

    2009-01-01

    We present a model for soft tissue deformation derived empirically from 10 pig carcases. The carcasses are subjected to deformation from a known single source of pressure located at the skin surface, and the deformation is quantified by means of steel markers injected into the tissue. The steel...... markers are easy to distinguish from the surrounding soft tissue in 3D computed tomography images. By tracking corresponding markers using methods from point-based registration, we are able to accurately quantify the magnitude and propagation of the induced deformation. The deformation is parameterised...

  18. Microwave tomography for functional imaging of extremity soft tissues: feasibility assessment

    International Nuclear Information System (INIS)

    Semenov, Serguei; Kellam, James; Althausen, Peter; Williams, Thomas; Abubakar, Aria; Bulyshev, Alexander; Sizov, Yuri

    2007-01-01

    It is important to assess the viability of extremity soft tissues, as this component is often the determinant of the final outcome of fracture treatment. Microwave tomography (MWT) and sensing might be able to provide a fast and mobile assessment of such properties. MWT imaging of extremities possesses a complicated, nonlinear, high dielectric contrast inverse problem of diffraction tomography. There is a high dielectric contrast between bone and soft tissue in the extremities. A contrast between soft tissue abnormalities is less pronounced when compared with the high bone-soft tissue contrast. The goal of this study was to assess the feasibility of MWT for functional imaging of extremity soft tissues, i.e. to detect a relatively small contrast within soft tissues in closer proximity to high contrast boney areas. Both experimental studies and computer simulation were performed. Experiments were conducted using live pigs with compromised blood flow and compartment syndrome within an extremity. A whole 2D tomographic imaging cycle at 1 GHz was computer simulated and images were reconstructed using the Newton, MR-CSI and modified Born methods. Results of experimental studies demonstrate that microwave technology is sensitive to changes in the soft tissue blood content and elevated compartment pressure. It was demonstrated that MWT is feasible for functional imaging of extremity soft tissues, circulatory-related changes, blood flow and elevated compartment pressure

  19. Computed radiography for breast cancer

    International Nuclear Information System (INIS)

    Yamada, Tatsuya; Muramatsu, Yukio

    1990-01-01

    In order to evaluate the possibility of using computed radiographic mammography in mass surveys of the breast, we have retrospectively examined 71 breast cancer lesions in 71 patients using computed radiographic and conventional non-screen mammographies and have carried out comparative studies on tumor detection rate and calcification. A 95.8% detection rate was obtained for the tumor image (n 71) using computed radiography (CR) and one of 93.0% using non-screen techniques. Three lesions remained undetected by either study. A 100% detection rate was obtained for calcification associated with cancer (n 33) from each method. No significant differences in either detection rate or calcification were seen between the two images. On the other hand, the ability to recognize tumor images (n 66) was as follows; CR superior to non-screen radiography in 53 lesions (80.3%), equal in eight lesions (12.1%) and inferior in five lesions (7.6%). For the calcification images (n 18), CR was superior to non-screen radiography in all 18 lesions. Obviously, CR gives better results than non-screen radiography. Furthermore, an adequate image can be obtained using CR even although the X-ray dosage is only a twentieth of that required for non-screen radiography. It can therefore be applied not only to mass surveys for breast cancer but also to routine clinical diagnoses. (author)

  20. Soft-tissue perineurioma of the retroperitoneum in a 63-year-old man, computed tomography and magnetic resonance imaging findings: a case report

    Directory of Open Access Journals (Sweden)

    Yasumoto Mayumi

    2010-08-01

    Full Text Available Abstract Introduction Soft-tissue perineuriomas are rare benign peripheral nerve sheath tumors in the subcutis of the extremities and the trunks of young patients. To our knowledge, this the first presentation of the computed tomography and magnetic resonance imaging of a soft-tissue perineurioma in the retroperitoneum with pathologic correlation. Case presentation A 63-year-old Japanese man was referred for assessment of high blood pressure. Abdominal computed tomography and magnetic resonance imaging showed a well-defined, gradually enhancing tumor without focal degeneration or hemorrhage adjacent to the pancreatic body. Tumor excision with distal pancreatectomy and splenectomy was performed, as a malignant tumor of pancreatic origin could not be ruled out. No recurrence has been noted in the 16 months since the operation. Pathologic examination of the tumor revealed a soft-tissue perineurioma of the retroperitoneum. Conclusion Although the definitive diagnosis of soft-tissue perineurioma requires biopsy and immunohistochemical reactivity evaluation, the computed tomography and magnetic resonance imaging findings described in this report suggest inclusion of this rare tumor in the differential diagnosis when such findings occur in the retroperitoneum.

  1. Application of computed radiography to ERCP

    International Nuclear Information System (INIS)

    Lee, Shigeki; Mochizuki, Fukuji; Fujita, Naotaka; Itoh, Shoichiro; Ikeda, Takashi; Toyohara, Tokiaki; Matsumoto, Kyoichi

    1984-01-01

    Computed radiography technic was applied to ERCP. Fuji Computed Radiography System was used. The pancreatogram obtained by this method was compared with that of conventional screen-film radiograph. The much finer changes of the pancreatogram can be delineated by the new method. The diagnostic ability of ERCP is thus enhanced by the introduction of FCR. (author)

  2. First cosmic-ray images of bone and soft tissue

    Science.gov (United States)

    Mrdja, Dusan; Bikit, Istvan; Bikit, Kristina; Slivka, Jaroslav; Hansman, Jan; Oláh, László; Varga, Dezső

    2016-11-01

    More than 120 years after Roentgen's first X-ray image, the first cosmic-ray muon images of bone and soft tissue are created. The pictures, shown in the present paper, represent the first radiographies of structures of organic origin ever recorded by cosmic rays. This result is achieved by a uniquely designed, simple and versatile cosmic-ray muon-imaging system, which consists of four plastic scintillation detectors and a muon tracker. This system does not use scattering or absorption of muons in order to deduct image information, but takes advantage of the production rate of secondaries in the target materials, detected in coincidence with muons. The 2D image slices of cow femur bone are obtained at several depths along the bone axis, together with the corresponding 3D image. Real organic soft tissue, polymethyl methacrylate and water, never seen before by any other muon imaging techniques, are also registered in the images. Thus, similar imaging systems, placed around structures of organic or inorganic origin, can be used for tomographic imaging using only the omnipresent cosmic radiation.

  3. Computed tomography in the evaluation of soft tissue tumors. Report in 124 cases

    Energy Technology Data Exchange (ETDEWEB)

    Torricelli, P; Calo, M; Boriani, S; De Santis, G

    1986-01-01

    In order to evaluate the role of Computed Tomography (CT) in prediction of nature, staging and follow-up of soft-tessue tumors, the authors examined by CT 124 patients with soft tissue neoplasms who later underwent surgery (116 cases) or fine needle biopsy (8 cases). Comparison between CT and surgical or anatomical results showed that CT was able to correctly predict the benignancy or malignancy of the masses in 76% of cases but it was very seldom able to allow an hystological prediction. On the contrary CT was found to be a very useful tool for pre-therapeutic staging and follow-up of the tumors, because it gave many diagnostic information which influenced therapeutic choiches and strategies. 39 refs.

  4. Computed Radiography Exposure Indices in Mammography | Koen ...

    African Journals Online (AJOL)

    Computed Radiography Exposure Indices in Mammography. L Koen, C Herbst, W Rae. Abstract. Background. Studies indicate that computed radiography (CR) can lead to increased radiation dose to patients. It is therefore important to relate the exposure indicators provided by CR manufacturers to the radiation dose ...

  5. Soft tissue deformation modelling through neural dynamics-based reaction-diffusion mechanics.

    Science.gov (United States)

    Zhang, Jinao; Zhong, Yongmin; Gu, Chengfan

    2018-05-30

    Soft tissue deformation modelling forms the basis of development of surgical simulation, surgical planning and robotic-assisted minimally invasive surgery. This paper presents a new methodology for modelling of soft tissue deformation based on reaction-diffusion mechanics via neural dynamics. The potential energy stored in soft tissues due to a mechanical load to deform tissues away from their rest state is treated as the equivalent transmembrane potential energy, and it is distributed in the tissue masses in the manner of reaction-diffusion propagation of nonlinear electrical waves. The reaction-diffusion propagation of mechanical potential energy and nonrigid mechanics of motion are combined to model soft tissue deformation and its dynamics, both of which are further formulated as the dynamics of cellular neural networks to achieve real-time computational performance. The proposed methodology is implemented with a haptic device for interactive soft tissue deformation with force feedback. Experimental results demonstrate that the proposed methodology exhibits nonlinear force-displacement relationship for nonlinear soft tissue deformation. Homogeneous, anisotropic and heterogeneous soft tissue material properties can be modelled through the inherent physical properties of mass points. Graphical abstract Soft tissue deformation modelling with haptic feedback via neural dynamics-based reaction-diffusion mechanics.

  6. Accuracy of cone beam computed tomography, intraoral radiography, and periodontal probing for periodontal bone defects measurement

    Directory of Open Access Journals (Sweden)

    Eskandarlo A

    2011-02-01

    Full Text Available "nBackground and Aims: Cone beam computed tomography (CBCT produces high-quality data about diagnosis and periodontal treatment. To date, there is not enough research regarding periodontal bone measurement using CBCT. The aim of this study was to compare the accuracy of CBCT in measuring periodontal defects to that of intraoral radiography and probing methods."nMaterials and Methods: Two-hundred and eighteen artificial osseous defects (buccal and lingual infrabony, interproximal, horizontal, crater, dehiscence and fenestration defects were created on 13 mandibles of dry skulls. The mandibles were put into a plexiglass box full of water to simulate soft tissue. CBCT images, radiographic images taken with parallel technique and direct measurements using a WHO periodontal probe were recorded and compared to a standard reference (digital caliper. Inter and intra observe consistencies were assessed using Intra class correlation coefficient and pearson correlation."nResults: Inter and intra observer consistencies were high for CBCT and probing methods (ICC- Intra class correlation coefficient>88%, but moderate for intraoral radiography (ICC-Intra class correlation coefficient > 54%. There were not any significant differences between observers for all techniques (P>0/05. According to paired T-test analysis, mean difference for CBCT technique (0.01 mm was lower than that for probing (0.04 mm and radiography (0.62 mm. CBCT was able to measure all kinds of lesions, but radiography could not measure defects in the buccal and lingual sites."nConclusion: All three modalities are useful for identifying periodontal defects. Compared to probing and radiography, the CBCT technique has the most accuracy in measuring periodontal defects.

  7. Preliminary clinical evaluation of hard- and soft-copy digitized chest radiography

    Science.gov (United States)

    Rian, Roger L.; Smerud, Michael J.; Guinn, Todd

    1994-05-01

    The digital applications in radiology are a controversial advanced which potentially will influence all areas of patient imaging. It is utilized and accepted in angiography, computed tomography, magnetic resonance, nuclear imaging and sonography. More recently Computed Radiography has gained credibility in mobile scenarios as well as specific applications from cervical spine radiography to digital fluoroscopy. Usually this acceptance is related to benefits of lesser radiation exposure or an improved presentation with an incorrect radiographic technique. One advantage of interpreting from digital information is the potential manipulation of the image presentation to the observer through windowing, leveling and edge enhancement pre and/or during image review. Additionally this digital data can be transmitted over distance and represented as hard and/or soft copy for primary or consultative review. The number and quality of the images to be viewed, the environment of the review station as well as the observer experience with conventional radiographic as well as digital image evaluation are important aspects of delivering the radiologist's product i.e. the final interpretation. This paper assesses that product, specifically addressing the question `Is the radiologist's report the same whether derived from the original analog image or from its digitized image.' The object of this study is to determine whether a digital system (3M PACS) designed for consultative viewing in a satellite department can also be used directly for primary diagnosis of conventional chest exams.

  8. Heavy-ion radiography applied to charged particle radiotherapy

    International Nuclear Information System (INIS)

    Chen, G.T.Y.; Fabrikant, J.I.; Holley, W.R.; Tobias, C.A.; Castro, J.R.

    1980-01-01

    The objectives of the heavy-ion radiography research program applied to the clinical cancer research program of charged particle radiotherapy have a twofold purpose: (1) to explore the manner in which heavy-ion radiography and CT reconstruction can provide improved tumor localization, treatment planning, and beam delivery for radiotherapy with accelerated heavy charged particles; and (2) to explore the usefulness of heavy-ion radiography in detecting, localizing, and sizing soft tissue cancers in the human body. The techniques and procedures developed for heavy-ion radiography should prove successful in support of charged particle radiotherapy

  9. Computed radiography in NDT application

    International Nuclear Information System (INIS)

    Deprins, Eric

    2004-01-01

    Computed Radiography, or digital radiography by use of reusable Storage Phosphor screens, offers a convenient and reliable way to replace film. In addition to the reduced cost on consumables, the return on investment of CR systems is strongly determined by savings in exposure time, processing times and archival times. But also intangible costs like plant shutdown, environment safety and longer usability of isotopes are increasingly important when considering replacing film by Storage Phosphor systems. But mote than in traditional radiography, the use of digital images is a trade-off between the speed and the required quality. Better image quality is obtained by longer exposure times, slower phosphor screens and higher scan resolutions. Therefore, different kinds of storage phosphor screens are needed in order to cover every application. Most operations have the data, associated with the tests to be performed, centrally stored in a database. Using a digital radiography system gives not only the advantages of the manipulation of digital images, but also the digital data that is associated with it. Smart methods to associate cassettes and Storage screens with exposed images enhance the workflow of the NDT processes, and avoid human error. Automated measurements tools increase the throughput in different kinds of operations. This paper gives an overview of the way certain operations have decided to replace film by Computed Radiography, and what the major benefits for them have been.

  10. Clinical management of soft tissue sarcomas

    International Nuclear Information System (INIS)

    Pinedo, H.M.; Verweij, J.

    1986-01-01

    This book is concerned with the clinical management of soft tissue sarcomas. Topics covered include: Radiotherapy; Pathology of soft tissue sarcomas; Surgical treatment of soft tissue sarcomas; and Chemotherapy in advanced soft tissue sarcomas

  11. Facial soft tissue thickness in North Indian adult population

    Directory of Open Access Journals (Sweden)

    Tanushri Saxena

    2012-01-01

    Full Text Available Objectives: Forensic facial reconstruction is an attempt to reproduce a likeness of facial features of an individual, based on characteristics of the skull, for the purpose of individual identification - The aim of this study was to determine the soft tissue thickness values of individuals of Bareilly population, Uttar Pradesh, India and to evaluate whether these values can help in forensic identification. Study design: A total of 40 individuals (19 males, 21 females were evaluated using spiral computed tomographic (CT scan with 2 mm slice thickness in axial sections and soft tissue thicknesses were measured at seven midfacial anthropological facial landmarks. Results: It was found that facial soft tissue thickness values decreased with age. Soft tissue thickness values were less in females than in males, except at ramus region. Comparing the left and right values in individuals it was found to be not significant. Conclusion: Soft tissue thickness values are an important factor in facial reconstruction and also help in forensic identification of an individual. CT scan gives a good representation of these values and hence is considered an important tool in facial reconstruction- This study has been conducted in North Indian population and further studies with larger sample size can surely add to the data regarding soft tissue thicknesses.

  12. Radiological protection procedures for industrial applications of computed radiography

    International Nuclear Information System (INIS)

    Aquino, Josilto Oliveira de

    2009-03-01

    Due to its very particular characteristics, industrial radiography is responsible for roughly half of the relevant accidents in nuclear industry, in developed as well as in developing countries, according to the International Atomic Energy Agency (IAEA). Thus, safety and radiological protection in industrial gamma radiography have been receiving especial treatment by regulatory authorities of most Member States. The main objective of the present work was to evaluate, from the radioprotection point of view, the main advantages of computed radiography (CR) for filmless industrial radiography. In order to accomplish this, both techniques, i.e. conventional and filmless computed radiography were evaluated and compared through practical studies. After the studies performed at the present work it was concluded that computed radiography significantly reduces the inherent doses, reflecting in smaller restricted areas and costs, with consequent improvement in radiological protection and safety. (author)

  13. Three-dimensional CT imaging of soft-tissue anatomy

    International Nuclear Information System (INIS)

    Fishman, E.K.; Ney, D.R.; Magid, D.; Kuhlman, J.E.

    1988-01-01

    Three-dimensional display of computed tomographic data has been limited to skeletal structures. This was in part related to the reconstruction algorithm used, which relied on a binary classification scheme. A new algorithm, volumetric rendering with percentage classification, provides the ability to display three-dimensional images of muscle and soft tissue. A review was conducted of images in 35 cases in which muscle and/or soft tissue were part of the clinical problem. In all cases, individual muscle groups could be clearly identified and discriminated. Branching vessels in the range of 2.3 mm could be identified. Similarly, lymph nodes could be clearly defined. High-resolution three-dimensional images were found to be useful both in providing an increased understanding of complex muscle and soft tissue anatomy and in surgical planning

  14. Digital luminescent radiography for diagnosis of skeletal injuries

    International Nuclear Information System (INIS)

    Buddenbrock, B.; Mueller, R.D.; John, V.; Kock, H.J.; Hirche, H.; Voss, M.; Loehr, E.; Schmit-Neuerburg, K.P.

    1992-01-01

    In the course of a comparative study 231 patients with traumatic lesions in skeletal and soft tissue areas were X-rayed using conventional film radiography and digital luminescence radiography (DLR). The results were evaluated by radiologists and traumatologists on the basis of optimised image post-processing in addition to the standard digital presentations. The imaging quality of compacta, spongiosa, soft tissues, fracture lines and osteosynthesis material was assessed in comparison with the screen-film images. Whereas the standard digital presentation in the ''conventionally adjusted'' imaging mode was inferior to the screen-film radiograph, the ''edge-enhanced'' standard presentation proved to be advantageous in the imaging of soft tissues (frequency of first-place ratings: DLR conventional 6%, screen-film system 21%, DLR edge-enhanced 31%). In the overall evaluation high-frequency filtered inverse image post-processing showed the highest diagnostic potential (frequency of first-place ratings: 41%). A conclusive assessment of metal implants is hindered by overshoot artefacts and can only be achieved through time-consuming post-processing of the stored image data. (orig.)

  15. Vascular imaging with contrast agent in hard and soft tissues using microcomputed-tomography.

    Science.gov (United States)

    Blery, P; Pilet, P; Bossche, A Vanden-; Thery, A; Guicheux, J; Amouriq, Y; Espitalier, F; Mathieu, N; Weiss, P

    2016-04-01

    Vascularization is essential for many tissues and is a main requisite for various tissue-engineering strategies. Different techniques are used for highlighting vasculature, in vivo and ex vivo, in 2-D or 3-D including histological staining, immunohistochemistry, radiography, angiography, microscopy, computed tomography (CT) or micro-CT, both stand-alone and synchrotron system. Vascularization can be studied with or without a contrast agent. This paper presents the results obtained with the latest Skyscan micro-CT (Skyscan 1272, Bruker, Belgium) following barium sulphate injection replacing the bloodstream in comparison with results obtained with a Skyscan In Vivo 1076. Different hard and soft tissues were perfused with contrast agent and were harvested. Samples were analysed using both forms of micro-CT, and improved results were shown using this new micro-CT. This study highlights the vasculature using micro-CT methods. The results obtained with the Skyscan 1272 are clearly defined compared to results obtained with Skyscan 1076. In particular, this instrument highlights the high number of small vessels, which were not seen before at lower resolution. This new micro-CT opens broader possibilities in detection and characterization of the 3-D vascular tree to assess vascular tissue engineering strategies. © 2015 The Authors Journal of Microscopy © 2015 Royal Microscopical Society.

  16. Computed radiography

    International Nuclear Information System (INIS)

    Pupchek, G.

    2004-01-01

    Computed radiography (CR) is an image acquisition process that is used to create digital, 2-dimensional radiographs. CR employs a photostimulable phosphor-based imaging plate, replacing the standard x-ray film and intensifying screen combination. Conventional radiographic exposure equipment is used with no modification required to the existing system. CR can transform an analog x-ray department into a digital one and eliminates the need for chemicals, water, darkrooms and film processor headaches. (author)

  17. Soft tissue modelling with conical springs.

    Science.gov (United States)

    Omar, Nadzeri; Zhong, Yongmin; Jazar, Reza N; Subic, Aleksandar; Smith, Julian; Shirinzadeh, Bijan

    2015-01-01

    This paper presents a new method for real-time modelling soft tissue deformation. It improves the traditional mass-spring model with conical springs to deal with nonlinear mechanical behaviours of soft tissues. A conical spring model is developed to predict soft tissue deformation with reference to deformation patterns. The model parameters are formulated according to tissue deformation patterns and the nonlinear behaviours of soft tissues are modelled with the stiffness variation of conical spring. Experimental results show that the proposed method can describe different tissue deformation patterns using one single equation and also exhibit the typical mechanical behaviours of soft tissues.

  18. Optimization and real-time control for laser treatment of heterogeneous soft tissues.

    Science.gov (United States)

    Feng, Yusheng; Fuentes, David; Hawkins, Andrea; Bass, Jon M; Rylander, Marissa Nichole

    2009-01-01

    Predicting the outcome of thermotherapies in cancer treatment requires an accurate characterization of the bioheat transfer processes in soft tissues. Due to the biological and structural complexity of tumor (soft tissue) composition and vasculature, it is often very difficult to obtain reliable tissue properties that is one of the key factors for the accurate treatment outcome prediction. Efficient algorithms employing in vivo thermal measurements to determine heterogeneous thermal tissues properties in conjunction with a detailed sensitivity analysis can produce essential information for model development and optimal control. The goals of this paper are to present a general formulation of the bioheat transfer equation for heterogeneous soft tissues, review models and algorithms developed for cell damage, heat shock proteins, and soft tissues with nanoparticle inclusion, and demonstrate an overall computational strategy for developing a laser treatment framework with the ability to perform real-time robust calibrations and optimal control. This computational strategy can be applied to other thermotherapies using the heat source such as radio frequency or high intensity focused ultrasound.

  19. Prevalence of Soft Tissue Calcifications in CBCT Images of Mandibular Region.

    Science.gov (United States)

    Khojastepour, Leila; Haghnegahdar, Abdolaziz; Sayar, Hamed

    2017-06-01

    Most of the soft tissue calcifications within the head and neck region might not be accompanied by clinical symptoms but may indicate some pathological conditions. The aim of this research was to determine the prevalence of soft tissue calcifications in cone beam computed tomography (CBCT) images of mandibular region. In this cross sectional study the CBCT images of 602 patients including 294 men and 308 women with mean age 41.38±15.18 years were evaluated regarding the presence, anatomical location; type (single or multiple) and size of soft tissue calcification in mandibular region. All CBCT images were acquired by NewTom VGi scanner. Odds ratio and chi-square tests were used for data analysis and p < 0.05 was considered to be statistically significant. 156 out of 602 patients had at least one soft tissue calcification in their mandibular region (25.9%. of studied population with mean age 51.7±18.03 years). Men showed significantly higher rate of soft tissue calcification than women (30.3% vs. 21.8%). Soft tissue calcification was predominantly seen at posterior region of the mandible (88%) and most of them were single (60.7%). The prevalence of soft tissue calcification increased with age. Most of the detected soft tissue calcifications were smaller than 3mm (90%). Soft tissue calcifications in mandibular area were a relatively common finding especially in posterior region and more likely to happen in men and in older age group.

  20. Soft Tissue Sarcoma—Health Professional Version

    Science.gov (United States)

    Soft tissue sarcomas are malignant tumors that arise in any of the mesodermal tissues of the extremities, trunk and retroperitoneum, or head and neck. Soft tissue sarcomas may be heterogeneous. Find evidence-based information on soft tissue sarcoma treatment and research.

  1. Soft tissue deformation estimation by spatio-temporal Kalman filter finite element method.

    Science.gov (United States)

    Yarahmadian, Mehran; Zhong, Yongmin; Gu, Chengfan; Shin, Jaehyun

    2018-01-01

    Soft tissue modeling plays an important role in the development of surgical training simulators as well as in robot-assisted minimally invasive surgeries. It has been known that while the traditional Finite Element Method (FEM) promises the accurate modeling of soft tissue deformation, it still suffers from a slow computational process. This paper presents a Kalman filter finite element method to model soft tissue deformation in real time without sacrificing the traditional FEM accuracy. The proposed method employs the FEM equilibrium equation and formulates it as a filtering process to estimate soft tissue behavior using real-time measurement data. The model is temporally discretized using the Newmark method and further formulated as the system state equation. Simulation results demonstrate that the computational time of KF-FEM is approximately 10 times shorter than the traditional FEM and it is still as accurate as the traditional FEM. The normalized root-mean-square error of the proposed KF-FEM in reference to the traditional FEM is computed as 0.0116. It is concluded that the proposed method significantly improves the computational performance of the traditional FEM without sacrificing FEM accuracy. The proposed method also filters noises involved in system state and measurement data.

  2. Facial soft-tissue asymmetry in three-dimensional cone-beam computed tomography images of children with surgically corrected unilateral clefts.

    Science.gov (United States)

    Starbuck, John Marlow; Ghoneima, Ahmed; Kula, Katherine

    2014-03-01

    Cleft lip with or without cleft palate (CL/P) is a relatively common craniofacial malformation involving bony and soft-tissue disruptions of the nasolabial and dentoalveolar regions. The combination of CL/P and subsequent craniofacial surgeries to close the cleft and improve appearance of the cutaneous upper lip and nose can cause scarring and muscle pull, possibly resulting in soft-tissue depth asymmetries across the face. We tested the hypothesis that tissue depths in children with unilateral CL/P exhibit differences in symmetry across the sides of the face. Twenty-eight tissue depths were measured on cone-beam computed tomography images of children with unilateral CL/P (n = 55), aged 7 to 17 years, using Dolphin software (version 11.5). Significant differences in tissue depth symmetry were found around the cutaneous upper lip and nose in patients with unilateral CL/P.

  3. Necrotizing Soft Tissue Infection: Diagnostic Accuracy of Physical Examination, Imaging, and LRINEC Score: A Systematic Review and Meta-Analysis.

    Science.gov (United States)

    Fernando, Shannon M; Tran, Alexandre; Cheng, Wei; Rochwerg, Bram; Kyeremanteng, Kwadwo; Seely, Andrew J E; Inaba, Kenji; Perry, Jeffrey J

    2018-04-18

    We sought to summarize accuracy of physical examination, imaging, and Laboratory Risk Indicator for Necrotizing Fasciitis (LRINEC) score in diagnosis of necrotizing soft tissue infection (NSTI) in adults with a soft tissue infection clinically concerning for NSTI. NSTI is a life-threatening diagnosis. Delay to diagnosis and surgical management is associated with increased mortality. We searched 6 databases from inception through November 2017. We included English-language studies reporting diagnostic accuracy of testing or LRINEC Score. Outcome was NSTI confirmed by surgery or histopathology. Two reviewers screened all citations and extracted data independently. Summary measures were obtained from the Hierarchical Summary Receiver Operating Characteristic model. From 2,290 citations, we included 23 studies (n = 5982). Of physical examination signs, pooled sensitivity and specificity for fever was 46.0% and 77.0% respectively, for hemorrhagic bullae 25.2% and 95.8%, and for hypotension 21.0% and 97.7%. Computed tomography (CT) had sensitivity of 88.5% and specificity of 93.3%, while plain radiography had sensitivity of 48.9% and specificity of 94.0%. Finally, LRINEC ≥ 6 had sensitivity of 68.2% and specificity of 84.8%, while LRINEC ≥ 8 had sensitivity of 40.8% and specificity of 94.9%. Absence of any 1 physical examination feature (eg, fever or hypotension) is not sufficient to rule-out NSTI. CT is superior to plain radiography. LRINEC had poor sensitivity, and should not be used to rule-out NSTI. Given the poor sensitivity of these tests, a high clinical suspicion warrants early surgical consultation for definitive diagnosis and management.

  4. Correlation Between Bone and Soft Tissue Thickness in Maxillary Anterior Teeth

    Directory of Open Access Journals (Sweden)

    Nasrin Esfahanizadeh

    2016-12-01

    Full Text Available Objectives: The purpose of this study was to determine buccal bone and soft tissue thicknesses and their correlation in the maxillary anterior region using cone beam computed tomography (CBCT.Materials and Methods: In this cross sectional study, 330 sound maxillary incisors in 60 patients with a mean age of 37.5 years were assessed by CBCT scans. For better visualization of soft tissue, patients were asked to use plastic retractors in order to retract their lips and cheeks away from the gingival tissue before taking the scans. Measurements were made in three different positions: at the crest and at 2 and 5mm apical to the crest. The cementoenamel junction‒crest distance was measured. for data analyses, the Pearson’s correlation coefficient, ANOVA and intraclass correlation coefficient were used.Results: There were mildly significant linear associations between labial soft tissue and bone thickness in the canines and incisors (r<0.40, P<0.05, but no association was found for the lateral incisors. The mean thickness of buccal bone differed significantly in the maxillary anterior teeth, being greater for the lateral incisors (P<0.05. For soft tissue thickness, the results were the same, and the least thickness was recorded for the canines. There was a mild association between labial soft tissue and bone thickness in canines and incisors (r=0.2, P=0.3, but no such linear association was seen for the lateral incisors.Conclusions: The mean thickness of buccal bone and soft tissue in the anterior maxilla was <1mm and there was a mild linear correlation between them.Keywords: Facial Bones; Cone-Beam Computed Tomography; Maxilla; Esthetics, Dental

  5. Soft-tissue tension total knee arthroplasty.

    Science.gov (United States)

    Asano, Hiroshi; Hoshino, Akiho; Wilton, Tim J

    2004-08-01

    It is far from clear how best to define the proper strength of soft-tissue tensioning in total knee arthroplasty (TKA). We attached a torque driver to the Monogram balancer/tensor device and measured soft-tissue tension in full extension and 90 degrees flexion during TKA. In our surgical procedure, when we felt proper soft-tissue tension was being applied, the mean distraction force was noted to be 126N in extension and 121N in flexion. There was no significant correlation between soft-tissue tension and the postoperative flexion angle finally achieved. To the best of our knowledge, this is the first study to assess the actual distraction forces in relation to soft-tissue tension in TKA. Further study may reveal the most appropriate forces to achieve proper soft-tissue tension in the wide variety of circumstances presenting at knee arthroplasty.

  6. Radiosensitivity of soft tissue sarcomas

    International Nuclear Information System (INIS)

    Hirano, Toru; Iwasaki, Katsuro; Suzuki, Ryohei; Monzen, Yoshio; Hombo, Zenichiro

    1989-01-01

    The correlation between the effectiveness of radiation therapy and the histology of soft tissue sarcomas was investigated. Of 31 cases with a soft tissue sarcoma of an extremity treated by conservative surgery and postoperative radiation of 3,000-6,000 cGy, local recurrence occurred in 12; 5 out of 7 synovial sarcomas, 4 of 9 MFH, one of 8 liposarcomas, none of 4 rhabdomyosarcomas and 2 of 3 others. As for the histological subtyping, the 31 soft tissue sarcomas were divided into spindle cell, pleomorphic cell, myxoid and round cell type, and recurrence rates were 75%, 33.3%, 16.7% and 0%, respectively. From the remarkable difference in recurrent rate, it was suggested that round cell and myxoid type of soft tissue sarcomas showed a high radiosensitivity compared to the spindle cell type with low sensitivity. Clarifying the degree of radiosensitivity is helpful in deciding on the management of limb salvage in soft tissue sarcomas of an extremity. (author)

  7. Assessment of survey radiography and comparison with x-ray computed tomography for detection of hyperfunctioning adrenocortical tumors in dogs

    International Nuclear Information System (INIS)

    Voorhout, G.; Stolp, R.; Rijnberk, A.; Waes, P.F.G.M. van

    1990-01-01

    Results of abdominal survey radiography and x-ray computed tomography (CT) were compared in 13 dogs with hyperadrenocorticism histologically attributed to adrenocortical tumors. X-ray computed tomography enabled accurate localization of the tumor in all 13 dogs. Apart from 2 poorly demarcated irregular-shaped and mineralized carcinomas, there were no differences between adenoma (n = 3) and carcinoma (n = 10) on CT images. In 1 dog, invasion of the caudal vena cava by the tumor was suggested on CT images and was confirmed during surgery. Suspicion of adhesions between tumors of the right adrenal gland and the caudal vena cava on the basis of CT images was confirmed during surgery in only 2 of 6 dogs. Survey radiography allowed accurate localization of the tumor in 7 dogs (4 on the right side and 3 on the left). In 6 of these dogs, the tumor was visible as a well-demarcated soft tissue mass and, in the other dog, as a poorly demarcated mineralized mass. The smallest tumor visualized on survey radiographs had a diameter of 20 mm on CT images. Six tumors with diameter less than or equal to 20 mm were not visualized on survey radiographs. In 1 of these dogs, a mineralized nodule was found in the left adrenal region, without evidence of a mass. In a considerable number of cases, survey radiography can provide presurgical localization of adrenocortical tumors in dogs with hyperadrenocorticism; CT is redundant in these instances. In the absence of positive radiographic findings, CT is valuable for localization of adrenocortical tumors

  8. In vivo X-Ray Computed Tomographic Imaging of Soft Tissue with Native, Intravenous, or Oral Contrast

    Directory of Open Access Journals (Sweden)

    W. Matthew Leevy

    2013-05-01

    Full Text Available X-ray Computed Tomography (CT is one of the most commonly utilized anatomical imaging modalities for both research and clinical purposes. CT combines high-resolution, three-dimensional data with relatively fast acquisition to provide a solid platform for non-invasive human or specimen imaging. The primary limitation of CT is its inability to distinguish many soft tissues based on native contrast. While bone has high contrast within a CT image due to its material density from calcium phosphate, soft tissue is less dense and many are homogenous in density. This presents a challenge in distinguishing one type of soft tissue from another. A couple exceptions include the lungs as well as fat, both of which have unique densities owing to the presence of air or bulk hydrocarbons, respectively. In order to facilitate X-ray CT imaging of other structures, a range of contrast agents have been developed to selectively identify and visualize the anatomical properties of individual tissues. Most agents incorporate atoms like iodine, gold, or barium because of their ability to absorb X-rays, and thus impart contrast to a given organ system. Here we review the strategies available to visualize lung, fat, brain, kidney, liver, spleen, vasculature, gastrointestinal tract, and liver tissues of living mice using either innate contrast, or commercial injectable or ingestible agents with selective perfusion. Further, we demonstrate how each of these approaches will facilitate the non-invasive, longitudinal, in vivo imaging of pre-clinical disease models at each anatomical site.

  9. In vivo X-Ray Computed Tomographic Imaging of Soft Tissue with Native, Intravenous, or Oral Contrast

    Science.gov (United States)

    Wathen, Connor A.; Foje, Nathan; van Avermaete, Tony; Miramontes, Bernadette; Chapaman, Sarah E.; Sasser, Todd A.; Kannan, Raghuraman; Gerstler, Steven; Leevy, W. Matthew

    2013-01-01

    X-ray Computed Tomography (CT) is one of the most commonly utilized anatomical imaging modalities for both research and clinical purposes. CT combines high-resolution, three-dimensional data with relatively fast acquisition to provide a solid platform for non-invasive human or specimen imaging. The primary limitation of CT is its inability to distinguish many soft tissues based on native contrast. While bone has high contrast within a CT image due to its material density from calcium phosphate, soft tissue is less dense and many are homogenous in density. This presents a challenge in distinguishing one type of soft tissue from another. A couple exceptions include the lungs as well as fat, both of which have unique densities owing to the presence of air or bulk hydrocarbons, respectively. In order to facilitate X-ray CT imaging of other structures, a range of contrast agents have been developed to selectively identify and visualize the anatomical properties of individual tissues. Most agents incorporate atoms like iodine, gold, or barium because of their ability to absorb X-rays, and thus impart contrast to a given organ system. Here we review the strategies available to visualize lung, fat, brain, kidney, liver, spleen, vasculature, gastrointestinal tract, and liver tissues of living mice using either innate contrast, or commercial injectable or ingestible agents with selective perfusion. Further, we demonstrate how each of these approaches will facilitate the non-invasive, longitudinal, in vivo imaging of pre-clinical disease models at each anatomical site. PMID:23711461

  10. Accuracy and reliability of facial soft tissue depth measurements using cone beam computer tomography

    NARCIS (Netherlands)

    Fourie, Zacharias; Damstra, Janalt; Gerrits, Pieter; Ren, Yijin

    2010-01-01

    It is important to have accurate and reliable measurements of soft tissue thickness for specific landmarks of the face and scalp when producing a facial reconstruction. In the past several methods have been created to measure facial soft tissue thickness (FSTT) in cadavers and in the living. The

  11. Soft tissue response and facial symmetry after orthognathic surgery.

    Science.gov (United States)

    Wermker, Kai; Kleinheinz, Johannes; Jung, Susanne; Dirksen, Dieter

    2014-09-01

    In orthognathic surgery aesthetic issues and facial symmetry are vital parameters in surgical planning. Aim of this investigation was to document and analyze the results of orthognathic surgery on the base of a three-dimensional photogrammetric assessment, to assess the soft tissue response related to the skeletal shift and the alterations in facial symmetry after orthognathic surgery. In this prospective clinical trial from January 2010 to June 2011, 104 patients were examined who underwent orthognathic surgery due to mono- or bimaxillary dysgnathia. The standardized measurements, based on optical 3D face scans, took place one day before orthognathic surgery (T1) and one day before removal of osteosynthesis material (T2). Soft tissue changes after procedures involving the mandible showed significant positive correlations and strong soft tissue response (p  0.05). The facial surfaces became more symmetric and harmonic with the exception of surgical maxillary expansion, but improvement of facial symmetry revealed no statistical significance. Soft tissue response after orthognathic surgery and symmetry are only partially predictable, especially in the maxillary and midfacial region. Computer programs predicting soft tissue changes are not currently safely reliable and should not be used or with caution to demonstrate a patient potential outcome of surgery. Copyright © 2014 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  12. Real-time haptic cutting of high-resolution soft tissues.

    Science.gov (United States)

    Wu, Jun; Westermann, Rüdiger; Dick, Christian

    2014-01-01

    We present our systematic efforts in advancing the computational performance of physically accurate soft tissue cutting simulation, which is at the core of surgery simulators in general. We demonstrate a real-time performance of 15 simulation frames per second for haptic soft tissue cutting of a deformable body at an effective resolution of 170,000 finite elements. This is achieved by the following innovative components: (1) a linked octree discretization of the deformable body, which allows for fast and robust topological modifications of the simulation domain, (2) a composite finite element formulation, which thoroughly reduces the number of simulation degrees of freedom and thus enables to carefully balance simulation performance and accuracy, (3) a highly efficient geometric multigrid solver for solving the linear systems of equations arising from implicit time integration, (4) an efficient collision detection algorithm that effectively exploits the composition structure, and (5) a stable haptic rendering algorithm for computing the feedback forces. Considering that our method increases the finite element resolution for physically accurate real-time soft tissue cutting simulation by an order of magnitude, our technique has a high potential to significantly advance the realism of surgery simulators.

  13. Giant cell tumor of soft tissue: a case report with emphasis on MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Moon Young; Jee, Won-Hee [The Catholic University of Korea, Department of Radiology, Seoul St. Mary' s Hospital, School of Medicine, Seocho-gu, Seoul (Korea, Republic of); Jung, Chan Kwon [The Catholic University of Korea, Department of Pathology, Seoul St. Mary' s Hospital, College of Medicine, Seocho-gu, Seoul (Korea, Republic of); Yoo, Ie Ryung [The Catholic University of Korea, Department of Nuclear Medicine, Seoul St. Mary' s Hospital, College of Medicine, Seocho-gu, Seoul (Korea, Republic of); Chung, Yang-Guk [The Catholic University of Korea, Department of Orthopedic Surgery, Seoul St. Mary' s Hospital, College of Medicine, Seocho-gu, Seoul (Korea, Republic of)

    2015-04-03

    Giant cell tumor of soft tissue is a rare neoplasm, histologically resembling giant cell tumor of bone. In this report, we describe a deep and solid giant cell tumor of soft tissue interpreted as a benign soft tissue tumor based on magnetic resonance (MR) findings with hypointense to intermediate signals on T2-weighted images and impeded diffusivity (water movement) on diffusion-weighted imaging (DWI), which could suggest a giant-cell-containing benign soft tissue tumor, despite the malignancy suggested by {sup 18}F-fluorodeoxyglucose positron emission tomography-computed tomography in a 35-year-old male. To our knowledge, this report introduces the first deep, solid giant cell tumor of soft tissue with MR features of a giant-cell-containing benign soft tissue tumor, despite the malignancy-mimicking findings on {sup 18}F-FDG PET-CT. (orig.)

  14. Estimating patient-specific soft-tissue properties in a TKA knee.

    Science.gov (United States)

    Ewing, Joseph A; Kaufman, Michelle K; Hutter, Erin E; Granger, Jeffrey F; Beal, Matthew D; Piazza, Stephen J; Siston, Robert A

    2016-03-01

    Surgical technique is one factor that has been identified as critical to success of total knee arthroplasty. Researchers have shown that computer simulations can aid in determining how decisions in the operating room generally affect post-operative outcomes. However, to use simulations to make clinically relevant predictions about knee forces and motions for a specific total knee patient, patient-specific models are needed. This study introduces a methodology for estimating knee soft-tissue properties of an individual total knee patient. A custom surgical navigation system and stability device were used to measure the force-displacement relationship of the knee. Soft-tissue properties were estimated using a parameter optimization that matched simulated tibiofemoral kinematics with experimental tibiofemoral kinematics. Simulations using optimized ligament properties had an average root mean square error of 3.5° across all tests while simulations using generic ligament properties taken from literature had an average root mean square error of 8.4°. Specimens showed large variability among ligament properties regardless of similarities in prosthetic component alignment and measured knee laxity. These results demonstrate the importance of soft-tissue properties in determining knee stability, and suggest that to make clinically relevant predictions of post-operative knee motions and forces using computer simulations, patient-specific soft-tissue properties are needed. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  15. Electroroentgenography in diagnosis of soft tissue tumors

    International Nuclear Information System (INIS)

    Vintergal'ter, S.F.; Vishevnik, B.I.

    1989-01-01

    Clinical, electroroentgenographic and X-ray studies of soft tissues were carried out in 425 patients with malignant (75), benign (246) soft tissue tumors and in cases of such soft tissue pathologies of the extremities and body (104). The paper discusses the technicalities of electroroentgenography which produces on one roentgenogram separate images of all components of soft tissues and bones in a given segment. A comparions of image quality assured by electroroentgeno- and roentgenography did not establish any significant difference in soft tissue tumor semiotics

  16. A new ChainMail approach for real-time soft tissue simulation.

    Science.gov (United States)

    Zhang, Jinao; Zhong, Yongmin; Smith, Julian; Gu, Chengfan

    2016-07-03

    This paper presents a new ChainMail method for real-time soft tissue simulation. This method enables the use of different material properties for chain elements to accommodate various materials. Based on the ChainMail bounding region, a new time-saving scheme is developed to improve computational efficiency for isotropic materials. The proposed method also conserves volume and strain energy. Experimental results demonstrate that the proposed ChainMail method can not only accommodate isotropic, anisotropic and heterogeneous materials but also model incompressibility and relaxation behaviors of soft tissues. Further, the proposed method can achieve real-time computational performance.

  17. Corrosion Surveillance In Pipe By Computed Radiography

    International Nuclear Information System (INIS)

    Nguyen The Man; Dao Duy Dung; Dang Thu Hong; Le Duc Thinh; Ha Hong Thu; Nguyen Trong Nghia

    2014-01-01

    Computed Radiography (CR) is a technique of digital industrial radiology which is developed to replace conventional radiography. With a CR system, the detection of the outer and inner wall surface of the pipe is done usually by edge detection and filter algorithms of the profile line at the position under investigation. Applying in industries, radiographic examination shall be performed in accordance with a written procedure. This paper summarizes collected knowledge and experimental results to establish a procedure for radiography applications in monitoring corrosion in small bore pipes. (author)

  18. Phase contrast enhanced high resolution X-ray imaging and tomography of soft tissue

    International Nuclear Information System (INIS)

    Jakubek, Jan; Granja, Carlos; Dammer, Jiri; Hanus, Robert; Holy, Tomas; Pospisil, Stanislav; Tykva, Richard; Uher, Josef; Vykydal, Zdenek

    2007-01-01

    A tabletop system for digital high resolution and high sensitivity X-ray micro-radiography has been developed for small-animal and soft-tissue imaging. The system is based on a micro-focus X-ray tube and the semiconductor hybrid position sensitive Medipix2 pixel detector. Transmission radiography imaging, conventionally based only on absorption, is enhanced by exploiting phase-shift effects induced in the X-ray beam traversing the sample. Phase contrast imaging is realized by object edge enhancement. DAQ is done by a novel fully integrated USB-based readout with online image generation. Improved signal reconstruction techniques make use of advanced statistical data analysis, enhanced beam hardening correction and direct thickness calibration of individual pixels. 2D and 3D micro-tomography images of several biological samples demonstrate the applicability of the system for biological and medical purposes including in-vivo and time dependent physiological studies in the life sciences

  19. Radiography of osseous lesions of the bovine locomotor system

    International Nuclear Information System (INIS)

    Blond, L.; Beauregard, G.; Mulon, P.Y.

    2006-01-01

    Radiography is the ancillary test of choice for lameness in cattle. Osseous lesions due to osteoporosis, osteitis or osteomyelitis and sequestrae can be visualised. Radiography is the only ancillary examination that provides a thorough investigation of the lesion affecting a bovine presented with a non-weight bearing suspected fracture and limb inflammation associated with soft tissue crepitation. Radiography is the only method to ensure that the fracture is not open. It facilitates follow-up of healing of osseous lesions. The period of time required for immobilisation can be adjusted depending on the type of lesions [it

  20. Computed Radiography: An Innovative Inspection Technique

    International Nuclear Information System (INIS)

    Klein, William A.; Councill, Donald L.

    2002-01-01

    Florida Power and Light Company's (FPL) Nuclear Division combined two diverse technologies to create an innovative inspection technique, Computed Radiography, that improves personnel safety and unit reliability while reducing inspection costs. This technique was pioneered in the medical field and applied in the Nuclear Division initially to detect piping degradation due to flow-accelerated corrosion. Component degradation can be detected by this additional technique. This approach permits FPL to reduce inspection costs, perform on line examinations (no generation curtailment), and to maintain or improve both personnel safety and unit reliability. Computed Radiography is a very versatile tool capable of other uses: - improving the external corrosion program by permitting inspections underneath insulation, and - diagnosing system and component problems such as valve positions, without the need to shutdown or disassemble the component. (authors)

  1. Radionuclide imaging of soft tissue neoplasms

    International Nuclear Information System (INIS)

    Chew, F.S.; Hudson, T.M.; Enneking, W.F.

    1981-01-01

    Two classes of radiopharmaceuticals may be used for imaging tumors of the musculoskeletal system. The first is comprised of soft tissue or tumor specific agents such as gallium-67, bleomycin, and radionuclide-labeled antibodies, which may be useful for detecting and localizing these tumors. The other class of tracer is comprised of those with avidity for bone. The 99mTc-labeled-phosphate skeletal imaging compounds have been found to localize in a variety of soft tissue lesions, including benign and malignant tumors. In 1972, Enneking began to include bone scans in the preoperative evaluation of soft tissue masses. Later, he and his associates reported that these scans were useful in planning operative treatment of sarcomas by detecting involvement of bone by the tumors. Nearly all malignant soft tissue tumors take up bone-seeking radiopharmaceuticals, and bone involvement was indicated in two-thirds of the scans we reviewed. About half of benign soft tissue lesions had normal scans, but the other half showed uptake within the lesion and a few also showed bone involvement. Careful, thorough imaging technique is essential to proper evaluation. Multiple, high-resolution static gamma camera images in different projections are necessary to adequately demonstrate the presence or absence of soft tissue abnormality and to define the precise relationship of the tumor to the adjacent bone

  2. An electromechanical based deformable model for soft tissue simulation.

    Science.gov (United States)

    Zhong, Yongmin; Shirinzadeh, Bijan; Smith, Julian; Gu, Chengfan

    2009-11-01

    Soft tissue deformation is of great importance to surgery simulation. Although a significant amount of research efforts have been dedicated to simulating the behaviours of soft tissues, modelling of soft tissue deformation is still a challenging problem. This paper presents a new deformable model for simulation of soft tissue deformation from the electromechanical viewpoint of soft tissues. Soft tissue deformation is formulated as a reaction-diffusion process coupled with a mechanical load. The mechanical load applied to a soft tissue to cause a deformation is incorporated into the reaction-diffusion system, and consequently distributed among mass points of the soft tissue. Reaction-diffusion of mechanical load and non-rigid mechanics of motion are combined to govern the simulation dynamics of soft tissue deformation. An improved reaction-diffusion model is developed to describe the distribution of the mechanical load in soft tissues. A three-layer artificial cellular neural network is constructed to solve the reaction-diffusion model for real-time simulation of soft tissue deformation. A gradient based method is established to derive internal forces from the distribution of the mechanical load. Integration with a haptic device has also been achieved to simulate soft tissue deformation with haptic feedback. The proposed methodology does not only predict the typical behaviours of living tissues, but it also accepts both local and large-range deformations. It also accommodates isotropic, anisotropic and inhomogeneous deformations by simple modification of diffusion coefficients.

  3. Computed tomography of the soft tissues of the shoulder. Pt. 3. Calcifying tendinitis of the rotator cuff

    Energy Technology Data Exchange (ETDEWEB)

    Dihlmann, W.; Bandick, J.

    1988-01-01

    Computed tomography of the soft tissue of the shoulder in cases of calcifying tendinitis of the rotator cuff provides the following information: 1. Localisation of the calcium deposits within the rotator cuff. 2. Contours and density of the calcium deposits correlated with the clinical findings as described by Uhthoff et al. Ill-defined contours and non-homogeneous deposits are associated with more severe clinical features. 3. Computed tomography shows that apatite particles, which are not visible radiologically, may penetrate into the shoulder joint and produce synovitis with an effusion. This is of importance in local therapy.

  4. WE-EF-303-10: Single- Detector Proton Radiography as a Portal Imaging Equivalent for Proton Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Doolan, P [University College London Hospital, London (United Kingdom); Bentefour, E [Ion Beam Applications, Louvain-la-Neuve (Belgium); Testa, M; Cascio, E; Lu, H [Massachussetts General Hospital, Boston, MA (United States); Royle, G [University College London, London (United Kingdom); Gottschalk, B [Harvard University, Cambridge, MA (United States)

    2015-06-15

    Purpose: In proton therapy, patient alignment is of critical importance due to the sensitivity of the proton range to tissue heterogeneities. Traditionally proton radiography is used for verification of the water-equivalent path length (WEPL), which dictates the depth protons reach. In this work we propose its use for alignment. Additionally, many new proton centers have cone-beam computed tomography in place of beamline X-ray imaging and so proton radiography offers a unique patient alignment verification similar to portal imaging in photon therapy. Method: Proton radiographs of a CIRS head phantom were acquired using the Beam Imaging System (BIS) (IBA, Louvain-la-Neuve) in a horizontal beamline. A scattered beam was produced using a small, dedicated, range modulator (RM) wheel fabricated out of aluminum. The RM wheel was rotated slowly (20 sec/rev) using a stepper motor to compensate for the frame rate of the BIS (120 ms). Dose rate functions (DRFs) over two RM wheel rotations were acquired. Calibration was made with known thicknesses of homogeneous solid water. For each pixel the time width, skewness and kurtosis of the DRFs were computed. The time width was used to compute the object WEPL. In the heterogeneous phantom, the excess skewness and excess kurtosis (i.e. difference from homogeneous cases) were computed and assessed for suitability for patient set up. Results: The technique allowed for the simultaneous production of images that can be used for WEPL verification, showing few internal details, and excess skewness and kurtosis images that can be used for soft tissue alignment. These latter images highlight areas where range mixing has occurred, correlating with phantom heterogeneities. Conclusion: The excess skewness and kurtosis images contain details that are not visible in the WET images. These images, unique to the time-resolved proton radiographic method, could be used for patient set up according to soft tissues.

  5. ChainMail based neural dynamics modeling of soft tissue deformation for surgical simulation.

    Science.gov (United States)

    Zhang, Jinao; Zhong, Yongmin; Smith, Julian; Gu, Chengfan

    2017-07-20

    Realistic and real-time modeling and simulation of soft tissue deformation is a fundamental research issue in the field of surgical simulation. In this paper, a novel cellular neural network approach is presented for modeling and simulation of soft tissue deformation by combining neural dynamics of cellular neural network with ChainMail mechanism. The proposed method formulates the problem of elastic deformation into cellular neural network activities to avoid the complex computation of elasticity. The local position adjustments of ChainMail are incorporated into the cellular neural network as the local connectivity of cells, through which the dynamic behaviors of soft tissue deformation are transformed into the neural dynamics of cellular neural network. Experiments demonstrate that the proposed neural network approach is capable of modeling the soft tissues' nonlinear deformation and typical mechanical behaviors. The proposed method not only improves ChainMail's linear deformation with the nonlinear characteristics of neural dynamics but also enables the cellular neural network to follow the principle of continuum mechanics to simulate soft tissue deformation.

  6. Percutaneous computed tomography-guided core needle biopsy of soft tissue tumors: results and correlation with surgical specimen analysis

    Energy Technology Data Exchange (ETDEWEB)

    Chojniak, Rubens; Grigio, Henrique Ramos; Bitencourt, Almir Galvao Vieira; Pinto, Paula Nicole Vieira; Tyng, Chiang J.; Cunha, Isabela Werneck da; Aguiar Junior, Samuel; Lopes, Ademar, E-mail: chojniak@uol.com.br [Hospital A.C. Camargo, Sao Paulo, SP (Brazil)

    2012-09-15

    Objective: To evaluate the efficacy of percutaneous computed tomography (CT)-guided core needle biopsy of soft tissue tumors in obtaining appropriate samples for histological analysis, and compare its diagnosis with the results of the surgical pathology as available. Materials and Methods: The authors reviewed medical records, imaging and histological reports of 262 patients with soft-tissue tumors submitted to CT-guided core needle biopsy in an oncologic reference center between 2003 and 2009. Results: Appropriate samples were obtained in 215 (82.1%) out of the 262 patients. The most prevalent tumors were sarcomas (38.6%), metastatic carcinomas (28.8%), benign mesenchymal tumors (20.5%) and lymphomas (9.3%). Histological grading was feasible in 92.8% of sarcoma patients, with the majority of them (77.9%) being classified as high grade tumors. Out of the total sample, 116 patients (44.3%) underwent surgical excision and diagnosis confirmation. Core biopsy demonstrated 94.6% accuracy in the identification of sarcomas, with 96.4% sensitivity and 89.5% specificity. A significant intermethod agreement about histological grading was observed between core biopsy and surgical resection (p < 0.001; kappa = 0.75). Conclusion: CT-guided core needle biopsy demonstrated a high diagnostic accuracy in the evaluation of soft tissue tumors as well as in the histological grading of sarcomas, allowing an appropriate therapeutic planning (author)

  7. Musculoskeletal Application of Ultrasound Elastography: Soft Tissue Lipoma

    International Nuclear Information System (INIS)

    Choi, Ja Young; Hong, Sung Hwan; Yoo, Hye Jin; Kim, Su Jin

    2010-01-01

    Real-time freehand elastography. Conventional ultrasonography (US) and real-time freehand US elastography were performed in nine patients (M:F = 4:5: mean age, 53 years: 29-64 years) with soft-tissue lipoma confirmed by surgical resection. The elastogram was color-coded by 256 scales according to the degree of strain induced by light compression. The relative strains for lipoma and surrounding soft tissue were measured and mean strains were examined by using a Wilcoxon signed rank test. The elastograms showed red to sky-blue color in all lipomas and predominantly black in surrounding soft tissue. The mean relative strain (±standard deviation) was 67.9±28.5, 77.1±25.3, 63.3±31.2, and 15.7±18.3 for total, intramuscular, and subcutaneous lipoma, and surrounding soft tissue, respectively. The mean strain of the lipoma was significantly higher than one of surrounding soft tissue (p = .008, Wilcoxon signed rank test). Real-time elastography yields characteristic elastographic features of soft tissue lipoma distinguishing from those of adjacent soft tissues

  8. Artery Soft-Tissue Modelling for Stent Implant Training System

    Directory of Open Access Journals (Sweden)

    Giovanni Aloisio

    2004-08-01

    Full Text Available Virtual reality technology can be utilised to provide new systematic training methods for surgical procedures. Our aim is to build a simulator that allows medical students to practice the coronary stent implant procedure and avoids exposing patients to risks. The designed simulation system consists of a virtual environment and a haptic interface, in order to provide both the visualization of the coronary arteries and the tactile and force feedback generated during the interactions of the surgical instruments in the virtual environment. Since the arteries are soft tissues, their shape may change during an operation; for this reason physical modelling of the organs is necessary to render their behaviour under the influence of surgeon's instruments. The idea is to define a model that computes the displacement of the tissue versus time; from the displacement it is possible to calculate the response of the tissue to the surgical tool external stimuli. Information about tools displacements and tissue responses are also used to graphically model the artery wall and virtual surgical instrument deformations generated as a consequence of their coming into contact. In order to obtain a realistic simulation, the Finite Element Method has been used to model the soft tissues of the artery, using linear elasticity to reduce computational time and speed up interaction rates.

  9. GPU-based real-time soft tissue deformation with cutting and haptic feedback.

    Science.gov (United States)

    Courtecuisse, Hadrien; Jung, Hoeryong; Allard, Jérémie; Duriez, Christian; Lee, Doo Yong; Cotin, Stéphane

    2010-12-01

    This article describes a series of contributions in the field of real-time simulation of soft tissue biomechanics. These contributions address various requirements for interactive simulation of complex surgical procedures. In particular, this article presents results in the areas of soft tissue deformation, contact modelling, simulation of cutting, and haptic rendering, which are all relevant to a variety of medical interventions. The contributions described in this article share a common underlying model of deformation and rely on GPU implementations to significantly improve computation times. This consistency in the modelling technique and computational approach ensures coherent results as well as efficient, robust and flexible solutions. Copyright © 2010 Elsevier Ltd. All rights reserved.

  10. Bones - joints - soft tissues II. 7. rev. ed.

    International Nuclear Information System (INIS)

    Dihlmann, W.; Frommhold, W.

    1991-01-01

    With the publication of the 2nd part to Volume VI, 'Bones - joints - soft tissues', the 7th edition of 'Diagnostic radiology in the hospital and medical practice' is complete. The advances made particularly during the past decade in the field of diagnostic radiology have made it neccesary for all the individual sections to be completely revised. Recently developed methods of imaging like sonography, computed tomography and magnetic resonance tomography are increasingly used as a replacement for or, at least, an adjunct to conventional X-ray procedures. Owing to the development and continuous refinement of related methods of intervention the gap between mere diagnostic applications and therapeutic uses of radiology could eventually be closed. The issues mainly discussed in this volume are bone fractures and healing, bone transplantation, osteopathy and osteoarthropathy, fibrous dyplasia or Albright's disease, Pagetoid osteitis, genetically transmitted constitutional disorders of the skeleton and soft tissue changes. While in the key sections on bone fractures and healing, osteopathy and osteoarthropathy as well as constitutional genetic disorders X-ray techniques are still described as the prevailing method of diagnosis, diseases of soft tissues now are much more commonly diagnosed using magnetic resonance imaging. (orig./MG) With 2248 figs., 59 tabs [de

  11. Computed tomography in sport injuries

    International Nuclear Information System (INIS)

    Reiser, M.; Rupp, N.

    1984-01-01

    Computed tomography (CT) provides axial slices plane and shows excellent details of bones and different soft tissues, favoring its use in traumatic lesions caused by sporting activities. Complex anatomical structures such as the shoulder, the vertebral column, the pelvis, the knee, the tarsal and carpal bones are often better recognized in detail than by conventional radiography. Fracture lines, localization of bone fragments and involvement of soft tissues are clearly demonstrated. Luxations and bone changes leading to luxations can be shown. CT arthrography provides for the first time a direct visualization of joint cartilage and of cruciate ligaments in the knee joint, so traumatic lesions such as chondropathia patellae or rupture of the cruciate ligaments are shown with a high degree of reliability. (orig.)

  12. Computed tomography in sport injuries

    Energy Technology Data Exchange (ETDEWEB)

    Reiser, M; Rupp, N

    1984-01-01

    Computed tomography (CT) provides axial slices plane and shows excellent details of bones and different soft tissues, favoring its use in traumatic lesions caused by sporting activities. Complex anatomical structures such as the shoulder, the vertebral column, the pelvis, the knee, the tarsal and carpal bones are often better recognized in detail than by conventional radiography. Fracture lines, localization of bone fragments and involvement of soft tissues are clearly demonstrated. Luxations and bone changes leading to luxations can be shown. CT arthrography provides for the first time a direct visualization of joint cartilage and of cruciate ligaments in the knee joint, so traumatic lesions such as chondropathia patellae or rupture of the cruciate ligaments are shown with a high degree of reliability.

  13. Dimensional soft tissue changes following soft tissue grafting in conjunction with implant placement or around present dental implants: a systematic review.

    Science.gov (United States)

    Poskevicius, Lukas; Sidlauskas, Antanas; Galindo-Moreno, Pablo; Juodzbalys, Gintaras

    2017-01-01

    To systematically review changes in mucosal soft tissue thickness and keratinised mucosa width after soft tissue grafting around dental implants. An electronic literature search was conducted of the MEDLINE database published between 2009 and 2014. Sequential screenings at the title, abstract, and full-text levels were performed. Clinical human studies in the English language that had reported changes in soft tissue thickness or keratinised mucosa width after soft tissue grafting at implant placement or around a present implant at 6-month follow-up or longer were included. The search resulted in fourteen articles meeting the inclusion criteria: Six of them reported connective tissue grafting around present dental implants, compared to eight at the time of implant placement. Better long-term soft tissue thickness outcomes were reported for soft tissue augmentation around dental implants (0.8-1.4 mm), compared with augmentation at implant placement (-0.25-1.43 mm). Both techniques were effective in increasing keratinised tissue width: at implant placement (2.5 mm) or around present dental implants (2.33-2.57 mm). The present systematic review discovered that connective tissue grafts enhanced keratinised mucosa width and soft tissue thickness for an observation period of up to 48 months. However, some shrinkage may occur, resulting in decreases in soft tissue, mostly for the first three months. Further investigations using accurate evaluation methods need to be done to evaluate the appropriate time for grafting. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  14. MR Histoanatomical Distribution of 290 Soft-tissue Tumors

    Energy Technology Data Exchange (ETDEWEB)

    Moon, Tae Yong; Lee, In Sook; Lee, Gee Won; Kim, Jeung Il; Choi, Kyung Un; Kim, Won Taek [Pusan National University Hospital, Busan (Korea, Republic of)

    2008-12-15

    This study was designed too identify the MR histoanatomical distribution of soft-tissue tumors. A total of 290 soft-tissue tumors of 281 patients were analyzed by the use of MR imaging and were pathologically confirmed after surgical resection or a biopsy. There were 120 malignant soft-tissue tumors including tumors of an intermediate malignancy and 170 benign tumors. The histoanatomical locations were divided into three types: 'type I' with superficial layer tumors that involved the cutaneous and subcutaneous tissue, 'type II' with deep layer tumors that involved the muscle or tendon and 'type III' with soft tissue tumors that involved both the superficial and deep layers. Soft-tissue tumors with more than three cases with a frequency of more than 75% included dermatofibrosarcoma protuberans, glomus tumor, angiolipoma, leiomyosarcoma and lymphoma as 'type I' tumors. 'Type II' tumors with more than three cases with a frequency of more than 75% included liposarcoma, fibromatosis, papillary endothelial hyperplasia and rhabdomyosarcoma. 'Type III' tumors with more than three cases with a frequency of more than 50% included neurofibromatosis. The MR histoanatomical distributions of soft tissue tumors are useful in the differential pathological diagnosis when a soft-tissue tumor has a nonspecific MR appearance.

  15. Soft-Tissue Chondroma of Anterior Gingiva: A Rare Entity

    Directory of Open Access Journals (Sweden)

    Dhana Lakshmi Jeyasivanesan

    2018-01-01

    Full Text Available Soft-tissue chondroma is a rare, benign, slow-growing tumor made up of heterotopic cartilaginous tissue. It occurs most commonly in the third and fourth decades in the hands and feet. Oral soft-tissue chondromas are uncommon and soft-tissue chondroma of gingiva is extremely uncommon. Here, we report an unusual case of soft-tissue chondroma of gingiva in a 50-year-old woman.

  16. Computed radiography imaging plates and associated methods of manufacture

    Science.gov (United States)

    Henry, Nathaniel F.; Moses, Alex K.

    2015-08-18

    Computed radiography imaging plates incorporating an intensifying material that is coupled to or intermixed with the phosphor layer, allowing electrons and/or low energy x-rays to impart their energy on the phosphor layer, while decreasing internal scattering and increasing resolution. The radiation needed to perform radiography can also be reduced as a result.

  17. Hardware for soft computing and soft computing for hardware

    CERN Document Server

    Nedjah, Nadia

    2014-01-01

    Single and Multi-Objective Evolutionary Computation (MOEA),  Genetic Algorithms (GAs), Artificial Neural Networks (ANNs), Fuzzy Controllers (FCs), Particle Swarm Optimization (PSO) and Ant colony Optimization (ACO) are becoming omnipresent in almost every intelligent system design. Unfortunately, the application of the majority of these techniques is complex and so requires a huge computational effort to yield useful and practical results. Therefore, dedicated hardware for evolutionary, neural and fuzzy computation is a key issue for designers. With the spread of reconfigurable hardware such as FPGAs, digital as well as analog hardware implementations of such computation become cost-effective. The idea behind this book is to offer a variety of hardware designs for soft computing techniques that can be embedded in any final product. Also, to introduce the successful application of soft computing technique to solve many hard problem encountered during the design of embedded hardware designs. Reconfigurable em...

  18. Análise de carcinomas epidermóides por meio de radiografia panorâmica e tomografia computadorizada Analysis of squamous cell carcinomas by means of panoramic radiography and computed tomography

    Directory of Open Access Journals (Sweden)

    Amanda Cáceres PEREIRA

    2001-12-01

    Full Text Available Este trabalho teve como objetivo correlacionar aspectos radiográficos como, localização e extensão do tumor, infiltração óssea e de tecidos moles e destruição das corticais, obtidos nas radiografias panorâmicas com os encontrados nas tomografias computadorizadas (TCs. Os aspectos radiográficos de 48 pacientes com diagnóstico histopatológico de carcinomas epidermóides, localizados em várias regiões do complexo buco-maxilo-facial, foram analisados por 4 radiologistas. As radiografias panorâmicas e as tomografias computadorizadas foram realizadas nos hospitais e clínicas da Universidade de Iowa (EUA, FUNDECTO - USP e Hospital Universitário da Universidade de São Paulo (SP, Brasil. Como resultados, obtivemos a grande limitação da radiografia panorâmica em determinar a localização e extensão do tumor, com delimitações bastante imprecisas da lesão. Já as TCs ofereceram resultados mais direcionados como: invasão do tumor em direção a estruturas moles adjacentes, extensão da destruição óssea, bem como a profundidade da lesão, que foram confirmados com os achados cirúrgicos. Concluímos que a tomografia computadorizada demonstrou ser uma técnica bastante sensível na detecção do comprometimento ósseo e do envolvimento de tecidos moles, proporcionando, assim, o auxílio no diagnóstico e no planejamento do tratamento. No entanto, a radiografia panorâmica foi muito pouco sensível e eficaz, por mostrar apenas margens imprecisas e pouco nítidas da lesão, não avaliando o envolvimento de tecidos moles.The purpose of this work was to compare radiographic findings, such as localization and extension of tumors toward the bone and soft tissues, in panoramic radiography and computed tomography (CT. Four radiologists assessed the radiographic findings of 48 patients with the histopathological diagnosis of squamous cell carcinoma in different sites of the maxillofacial region. Panoramic radiographs and computed

  19. Dimensional Changes of Fresh Sockets With Reactive Soft Tissue Preservation: A Cone Beam CT Study.

    Science.gov (United States)

    Crespi, Roberto; Capparé, Paolo; Crespi, Giovanni; Gastaldi, Giorgio; Gherlone, Enrico Felice

    2017-06-01

    The aim of this study was to assess dimensional changes of the fresh sockets grafted with collagen sheets and maintenance of reactive soft tissue, using cone beam computed tomography (CBCT). Tooth extractions were performed with maximum preservation of the alveolar housing, reactive soft tissue was left into the sockets and collagen sheets filled bone defects. Cone beam computed tomography were performed before and 3 months after extractions. One hundred forty-five teeth, 60 monoradiculars and 85 molars, were extracted. In total, 269 alveoli were evaluated. In Group A, not statistically significant differences were found between monoradiculars, whereas statistically significant differences (P 0.05) for all types of teeth. This study reported an atraumatic tooth extraction, reactive soft tissue left in situ, and grafted collagen sponge may be helpful to reduce fresh socket collapse after extraction procedures.

  20. Computer processing techniques in digital radiography research

    International Nuclear Information System (INIS)

    Pickens, D.R.; Kugel, J.A.; Waddill, W.B.; Smith, G.D.; Martin, V.N.; Price, R.R.; James, A.E. Jr.

    1985-01-01

    In the Department of Radiology and Radiological Sciences, Vanderbilt University Medical Center, and the Center for Medical Imaging Research, Nashville, TN, there are several activities which are designed to increase the information available from film-screen acquisition as well as from direct digital acquisition of radiographic information. Two of the projects involve altering the display of images after acquisition, either to remove artifacts present as a result of the acquisition process or to change the manner in which the image is displayed to improve the perception of details in the image. These two projects use methods which can be applied to any type of digital image, but are being implemented with images digitized from conventional x-ray film. One of these research endeavors involves mathematical alteration of the image to correct for motion artifacts or registration errors between images that will be subtracted. Another applies well-known image processing methods to digital radiographic images to improve the image contrast and enhance subtle details in the image. A third project involves the use of dual energy imaging with a digital radiography system to reconstruct images which demonstrate either soft tissue details or the osseous structures. These projects are discussed in greater detail in the following sections of this communication

  1. Collecting and Storing Tissue, Blood, and Bone Marrow Samples From Patients With Rhabdomyosarcoma or Other Soft Tissue Sarcoma

    Science.gov (United States)

    2017-12-11

    Adult Rhabdomyosarcoma; Childhood Desmoplastic Small Round Cell Tumor; Chordoma; Desmoid Tumor; Metastatic Childhood Soft Tissue Sarcoma; Nonmetastatic Childhood Soft Tissue Sarcoma; Previously Treated Childhood Rhabdomyosarcoma; Previously Untreated Childhood Rhabdomyosarcoma; Recurrent Adult Soft Tissue Sarcoma; Recurrent Childhood Rhabdomyosarcoma; Recurrent Childhood Soft Tissue Sarcoma; Stage I Adult Soft Tissue Sarcoma; Stage II Adult Soft Tissue Sarcoma; Stage III Adult Soft Tissue Sarcoma; Stage IV Adult Soft Tissue Sarcoma

  2. Necrotising soft tissue infection following mastectomy

    Directory of Open Access Journals (Sweden)

    Jackson P

    2010-03-01

    Full Text Available Necrotising fasciitis is a rare but rapidly progressive soft tissue disease which can lead to extensive necrosis, systemic sepsis and death. Including this case, only 7 other cases have been reported in the world literature with only 2 others affecting the patient post mastectomy.This 59 year old Caucasian lady presented with severe soft tissue infection soon after mastectomy, which was successfully treated with a combination of debridement, triangulation, VAC© dressing and skin grafting.Necrotising soft tissue infections following mastectomy are rapidly progressive and potentially extremely serious. It is essential that a high index of clinical suspicion is maintained together with prompt aggressive treatment in a multidisciplinary environment to prevent worsening physical and psychological sequelae.

  3. Soft tissue grafting to improve implant esthetics

    Directory of Open Access Journals (Sweden)

    Moawia M Kassab

    2010-09-01

    Full Text Available Moawia M KassabDivision of Periodontics, Marquette University, School of Dentistry, Milwaukee, WI, USAAbstract: Dental implants are becoming the treatment of choice to replace missing teeth, especially if the adjacent teeth are free of restorations. When minimal bone width is present, implant placement becomes a challenge and often resulting in recession and dehiscence around the implant that leads to subsequent gingival recession. To correct such defect, the author turned to soft tissue autografting and allografting to correct a buccal dehiscence around tooth #24 after a malpositioned implant placed by a different surgeon. A 25-year-old woman presented with the chief complaint of gingival recession and exposure of implant threads around tooth #24. The patient received three soft tissue grafting procedures to augment the gingival tissue. The first surgery included a connective tissue graft to increase the width of the keratinized gingival tissue. The second surgery included the use of autografting (connective tissue graft to coronally position the soft tissue and achieve implant coverage. The third and final surgery included the use of allografting material Alloderm to increase and mask the implant from showing through the gingiva. Healing period was uneventful for the patient. After three surgical procedures, it appears that soft tissue grafting has increased the width and height of the gingiva surrounding the implant. The accomplished thickness of gingival tissue appeared to mask the showing of implant threads through the gingival tissue and allowed for achieving the desired esthetic that the patient desired. The aim of the study is to present a clinical case with soft tissue grafting procedures.Keywords: case report, connective tissue, dental implants, allograft, coronally positioned flap

  4. Modern Soft Tissue Pathology | Center for Cancer Research

    Science.gov (United States)

    This book comprehensively covers modern soft tissue pathology and includes both tumors and non-neoplastic entities. Soft tissues make up a large bulk of the human body, and they are susceptible to a wide range of diseases. Many soft-tissue tumors are biologically very aggressive, and the chance of them metastasizing to vital organs is quite high. In recent years, the outlook

  5. Hydatid disease of the soft tissues of the lower limb: findings in three cases

    International Nuclear Information System (INIS)

    Martin, J.; Marco, V.; Zidan, A.; Marco, C.

    1993-01-01

    Three cases of hydatid disease are reported, all presenting as soft tissue lesions in the lower extremities. All three cases were studied with ultrasound (US), two with computed tomography (CT), and two with magnetic resonance (MR) imaging techniques. Two patients presented with multivesicular lesions which were considered diagnostic of hydatid disease. The third patient showed a lesion with a predominantly solid pattern, closely mimicking a soft-tissue neoplasm. US was not diagnostic, but MR outlined vesicular structures and a fibrous pericyst. Hydatid disease presenting in the soft tissues can therefore be diagnosed with confidence when it shows multivesicular lesions but MR may be the most useful imaging technique when a complex or solid pattern is present. (orig.)

  6. Post-radiation soft tissue sarcoma

    International Nuclear Information System (INIS)

    Tomita, Yasuhiko; Kuratsu, Shigeyuki; Myoui, Akira; Ohsawa, Masahiko; Aozasa, Katsuyuki; Uchida, Atsumasa; Ono, Keiro

    1993-01-01

    Seven patients received radiation for malignancies, and two received for benign tumors. The latency period from radiation to symptom ranged from two years to 36 years (mean 17.2 years). Post-radiation soft tissue sarcomas (PRS) comprised six cases of malignant fibrous histiocytomas, two leiomyosarcomas, and one angiosarcoma. The five-year survival of PRS was 16.7% showing a worse prognosis than spontaneously occurring soft tissue sarcomas. Seven PRS occurred superficially, and two were deeply located. Four cases occurring in the superficial tissues had histories of radiation-induced dermatitis. The radiation-induced dermatitis was suggested to be a risk factor for development of PRS. (author)

  7. Direct detector radiography versus dual reading computed radiography: feasibility of dose reduction in chest radiography

    International Nuclear Information System (INIS)

    Gruber, Michael; Uffmann, Martin; Weber, Michael; Balassy, Csilla; Schaefer-Prokop, Cornelia; Prokop, Mathias

    2006-01-01

    The image quality of dual-reading computed radiography and dose-reduced direct radiography of the chest was compared in a clinical setting. The study group consisted of 50 patients that underwent three posteroanterior chest radiographs within minutes, one image obtained with a dual read-out computed radiography system (CR; Fuji 5501) at regular dose and two images with a flat panel direct detector unit (DR; Diagnost, Philips). The DR images were obtained with the same and with 50% of the dose used for the CR images. Images were evaluated in a blinded side-by-side comparison. Eight radiologists ranked the visually perceivable difference in image quality using a three-point scale. Then, three radiologists scored the visibility of anatomic landmarks in low and high attenuation areas and image noise. Statistical analysis was based on Friedman tests and Wilcoxon rank sum tests at a significance level of P<0.05. DR was judged superior to CR for the delineation of structures in high attenuation areas of the mediastinum even when obtained with 50% less dose (P<0.001). The visibility of most pulmonary structures was judged equivalent with both techniques, regardless of acquisition dose and speed level. Scores for image noise were lower for DR compared with CR, with the exception of DR obtained at a reduced dose. Thus, in this clinical preference study, DR was equivalent or even superior to the most modern dual read-out CR, even when obtained with 50% dose. A further dose reduction does not appear to be feasible for DR without significant loss of image quality. (orig.)

  8. Vascularization of soft tissue engineering constructs

    DEFF Research Database (Denmark)

    Pimentel Carletto, Rodrigo

    with mechanical properties in the range of soft tissues has not been fully achieved. My project focused on the fabrication and the active perfusion of hydrogel constructs with multi-dimensional vasculature and controlled mechanical properties targeting soft tissues. Specifically, the initial part of the research...... nanotechnology-based paradigm for engineering vascularised liver tissue for transplantation”) and the Danish National Research Foundation and Villum Foundation’s Center for Intelligent Drug delivery and sensing Using microcontainers and Nanomechanics (Danish National Research Foundation (DNRF122)....

  9. Computational radiology in skeletal radiography

    International Nuclear Information System (INIS)

    Peloschek, Ph.; Nemec, S.; Widhalm, P.; Donner, R.; Birngruber, E.; Thodberg, H.H.; Kainberger, F.; Langs, G.

    2009-01-01

    Recent years have brought rapid developments in computational image analysis in musculo-skeletal radiology. Meanwhile the algorithms have reached a maturity that makes initial clinical use feasible. Applications range from joint space measurement to erosion quantification, and from fracture detection to the assessment of alignment angles. Current results of computational image analysis in radiography are very promising, but some fundamental issues remain to be clarified, among which the definition of the optimal trade off between automatization and operator-dependency, the integration of these tools into clinical work flow and last not least the proof of incremental clinical benefit of these methods.

  10. Nasal Soft-Tissue Triangle Deformities.

    Science.gov (United States)

    Foda, Hossam M T

    2016-08-01

    The soft-tissue triangle is one of the least areas attended to in rhinoplasty. Any postoperative retraction, notching, or asymmetries of soft triangles can seriously affect the rhinoplasty outcome. A good understanding of the risk factors predisposing to soft triangle deformities is necessary to prevent such problems. The commonest risk factors in our study were the wide vertical domal angle between the lateral and intermediate crura, and the increased length of intermediate crus. Two types of soft triangle grafts were described to prevent and treat soft triangle deformities. The used soft triangle grafts resulted in an excellent long-term aesthetic and functional improvement. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  11. Comparison of low-contrast detectability of computed radiography and screen/ film mammography systems

    International Nuclear Information System (INIS)

    Noriah Jamal; Kwan-Hoong Ng; McLean, D.; McLean, D.

    2008-01-01

    The objective of this study is to compare low-contrast detectability of computed radiography (CR) and screen/ film (SF) mammography systems. The Nijimegen contrast detail test object (CDMAM type 3.4) was imaged at 28 kV, in automatic exposure control mode separately. Six medical imaging physicists read each CDMAM phantom image. Contrast detail curves were plotted to compare low-contrast detectability of CR (soft copy and hard copy) and SF mammography systems. Effect of varying exposure parameters, namely kV, object position inside the breast phantom, and entrance surface exposure (ESE) on the contrast detail curve were also investigated using soft copy CR. The significance of the difference in contrast between CR and SF, and for each exposure parameter, was tested using non-parametric Kruskal-Wallis test. The low-contrast detectability of the CR (soft copy and hard copy) system was found to be not significantly different to that of the SF system (p> 0.05, Kruskal-Wallis test).For CR soft copy, no significant relationship (p>0.05, Kruskal-Wallis test) was seen for variation of kV, object position inside the breast phantom and ESE. This indicates that CR is comparable with SF for useful detection and visualization of low-contrast objects such as small low-contrast areas corresponding to breast pathology. (Author)

  12. Computing dispersion curves of elastic/viscoelastic transversely-isotropic bone plates coupled with soft tissue and marrow using semi-analytical finite element (SAFE) method.

    Science.gov (United States)

    Nguyen, Vu-Hieu; Tran, Tho N H T; Sacchi, Mauricio D; Naili, Salah; Le, Lawrence H

    2017-08-01

    We present a semi-analytical finite element (SAFE) scheme for accurately computing the velocity dispersion and attenuation in a trilayered system consisting of a transversely-isotropic (TI) cortical bone plate sandwiched between the soft tissue and marrow layers. The soft tissue and marrow are mimicked by two fluid layers of finite thickness. A Kelvin-Voigt model accounts for the absorption of all three biological domains. The simulated dispersion curves are validated by the results from the commercial software DISPERSE and published literature. Finally, the algorithm is applied to a viscoelastic trilayered TI bone model to interpret the guided modes of an ex-vivo experimental data set from a bone phantom. Copyright © 2017 Elsevier Ltd. All rights reserved.

  13. Radiography after unexpected death in infants and children compared to autopsy

    International Nuclear Information System (INIS)

    Lange, Charlotte de; Stake, Gunnar; Vege, Aashild

    2007-01-01

    Postmortem radiography may reveal skeletal and soft-tissue abnormalities of importance for the diagnosis of cause of death. To review the radiographs of children under 3 years of age who had died suddenly and unexpectedly. To compare the radiological and autopsy findings evaluating possible differences in children dying of SIDS and of an explainable cause. A total of 110 consecutive skeletal surveys performed between 1998 and 2002 were reviewed. All but one were performed before autopsy and comprised AP views of the appendicular and axial skeleton and thorax/abdomen, lateral views of the axial skeleton and thorax, and two oblique views of the ribs. Radiography and autopsy findings were compared. Causes of death were classified as SIDS/borderline SIDS (n = 52) and non-SIDS (n = 58), with one case of abuse. In 102 infants there were 150 pathological findings, 88 involving the chest, 24 skeletal, and 38 miscellaneous findings. The radiological-pathological agreement was poor concerning pulmonary findings. Skeletal findings were sometimes important for the final diagnosis. Radiography revealed many skeletal and soft-tissue findings. Pulmonary pathology was most frequently found, but showed poor agreement with autopsy findings. Recognizing skeletal findings related to abuse is important, as these may escape recognition at autopsy. (orig.)

  14. MRI of soft tissue abnormalities: a primary cause of sickle cell crisis

    International Nuclear Information System (INIS)

    Feldman, F.; Zwass, A.; Staron, R.B.; Haramati, N.

    1993-01-01

    The early manifestations of sickle cell crisis in soft tissues are important to recognize, though rarely manifest on radiographs and difficult to evaluate on computed tomography and bone scans. Documentation is critical, however, if appropriate judgments as to emergency treatment versus conservative measures are to be made. Seventeen adults seen in the emergency room or hospitalized in presumed sickle cells crisis underwent magnetic resonance imaging within 24-72 h of presentation. Results indicate that magnetic resonance imaging is a sensitive modality for documenting early soft tissue pathology which may be the predominant or sole cause of sickle cell crisis. (orig.)

  15. An exploratory study of contrast agents for soft tissue visualization by means of high resolution X-ray computed tomography imaging.

    Science.gov (United States)

    Pauwels, E; Van Loo, D; Cornillie, P; Brabant, L; Van Hoorebeke, L

    2013-04-01

    High resolution X-ray computed tomography (CT), or microCT, is a promising and already widely used technique in various scientific fields. Also for histological purposes it has great potential. Although microCT has proven to be a valuable technique for the imaging of bone structures, the visualization of soft tissue structures is still an important challenge due to their low inherent X-ray contrast. One way to achieve contrast enhancement is to make use of contrast agents. However, contrary to light and electron microscopy, knowledge about contrast agents and staining procedures is limited for X-ray CT. The purpose of this paper is to identify useful X-ray contrast agents for soft tissue visualization, which can be applied in a simple way and are also suited for samples larger than (1 cm)(3) . And 28 chemical substances have been investigated. All chemicals were applied in the form of concentrated aqueous solutions in which the samples were immersed. First, strips of green Bacon were stained to evaluate contrast enhancement between muscle and adipose tissue. Furthermore it was also tested whether the contrast agents remained fixed in the tissue after staining by re-immersing them in water. Based on the results, 12 contrast agents were selected for further testing on postmortem mice hind legs, containing a variety of different tissues, including muscle, fat, bone, cartilage and tendons. It was evaluated whether the contrast agents allowed a clearer distinction between the different soft tissue structures present. Finally also penetration depth was measured. And 26 chemicals resulted in contrast enhancement between muscle and adipose tissue in the Bacon strips. Mercury(II)chloride (HgCl2 ), phosphotungstic acid (PTA), phosphomolybdic acid (PMA) and ammonium orthomolybdate ((NH4 )2 MoO4 ) remained fixed after re-immersion in water. The penetration tests showed that potassium iodide (KI) and sodium tungstate can be most efficiently used for large samples of the order

  16. MRI features of soft-tissue lumps and bumps

    International Nuclear Information System (INIS)

    Zhuang, K.D.; Tandon, A.A.; Ho, B.C.S.; Chong, B.K.

    2014-01-01

    Superficial soft-tissue lesions are frequently encountered by radiologists in everyday practice. Characterization of these soft-tissue lesions remains problematic, despite advances in imaging. By systematically using clinical history, anatomical location, and signal intensity characteristics on MRI images, one can determine the diagnosis for the subset of determinate lesions that have characteristic clinical and imaging features as well as narrow the differential diagnoses for lesions with non-specific or indeterminate characteristics. In this review, a spectrum of histologically proven benign and malignant superficial soft-tissue lesions from a single institution will be presented. In addition, a few tumour-like conditions will be included as they can be encountered during imaging of soft-tissue masses

  17. Assessment of weld thickness loss in offshore pipelines using computed radiography and computational modeling

    International Nuclear Information System (INIS)

    Correa, S.C.A.; Souza, E.M.; Oliveira, D.F.; Silva, A.X.; Lopes, R.T.; Marinho, C.; Camerini, C.S.

    2009-01-01

    In order to guarantee the structural integrity of oil plants it is crucial to monitor the amount of weld thickness loss in offshore pipelines. However, in spite of its relevance, this parameter is very difficult to determine, due to both the large diameter of most pipes and the complexity of the multi-variable system involved. In this study, a computational modeling based on Monte Carlo MCNPX code is combined with computed radiography to estimate the weld thickness loss in large-diameter offshore pipelines. Results show that computational modeling is a powerful tool to estimate intensity variations in radiographic images generated by weld thickness variations, and it can be combined with computed radiography to assess weld thickness loss in offshore and subsea pipelines.

  18. Phase-Contrast Hounsfield Units of Fixated and Non-Fixated Soft-Tissue Samples

    Science.gov (United States)

    Willner, Marian; Fior, Gabriel; Marschner, Mathias; Birnbacher, Lorenz; Schock, Jonathan; Braun, Christian; Fingerle, Alexander A.; Noël, Peter B.; Rummeny, Ernst J.; Pfeiffer, Franz; Herzen, Julia

    2015-01-01

    X-ray phase-contrast imaging is a novel technology that achieves high soft-tissue contrast. Although its clinical impact is still under investigation, the technique may potentially improve clinical diagnostics. In conventional attenuation-based X-ray computed tomography, radiological diagnostics are quantified by Hounsfield units. Corresponding Hounsfield units for phase-contrast imaging have been recently introduced, enabling a setup-independent comparison and standardized interpretation of imaging results. Thus far, the experimental values of few tissue types have been reported; these values have been determined from fixated tissue samples. This study presents phase-contrast Hounsfield units for various types of non-fixated human soft tissues. A large variety of tissue specimens ranging from adipose, muscle and connective tissues to liver, kidney and pancreas tissues were imaged by a grating interferometer with a rotating-anode X-ray tube and a photon-counting detector. Furthermore, we investigated the effects of formalin fixation on the quantitative phase-contrast imaging results. PMID:26322638

  19. Computed radiography versus mobile direct radiography for bedside chest radiographs: impact of dose on image quality and reader agreement

    NARCIS (Netherlands)

    de Boo, D. W.; Weber, M.; Deurloo, E. E.; Streekstra, G. J.; Freling, N. J.; Dongelmans, D. A.; Schaefer-Prokop, C. M.

    2011-01-01

    To asses the image quality and potential for dose reduction of mobile direct detector (DR) chest radiography as compared with computed radiography (CR) for intensive care unit (ICU) chest radiographs (CXR). Three groups of age-, weight- and disease-matched ICU patients (n=114 patients; 50 CXR per

  20. Quality assurance of computed and digital radiography systems

    International Nuclear Information System (INIS)

    Walsh, C.; Gorman, D.; Byrne, P.; Larkin, A.; Dowling, A.; Malone, J. F.

    2008-01-01

    Computed radiography (CR) and digital radiography (DR) are replacing traditional film screen radiography as hospitals move towards digital imaging and picture archiving and communication systems (PACS). Both IPEM and KCARE have recently published quality assurance and acceptance testing guidelines for DR. In this paper, the performance of a range of CR and DR systems is compared. Six different manufacturers are included. Particular attention is paid to the performance of the systems under automatic exposure control (AEC). The patient is simulated using a range of thicknesses of tissue equivalent material. Image quality assessment was based on detector assessment protocols and includes pixel value measures as well as subjective assessment using Leeds Test Objects. The protocols for detector assessment cover a broad range of tests and in general detectors (whether DR or CR) performed satisfactorily. The chief limitation in performing these tests was that not all systems provided ready access to pixel values. Subjective tests include the use of the Leeds TO20. As part of this work, suggested reference values are provided to calculate the TO20 image quality factor. One consequence of moving from film screen to digital technologies is that the dynamic range of digital detectors is much wider, and increased exposures are no longer evident from changes in image quality. As such, AEC is a key parameter for CR and DR. Dose was measured using a standard phantom as a basic means of comparing systems. In order to assess the AEC performance, exit doses were also measured while varying phantom thickness. Signal-to-noise ratios (SNRs) were calculated on a number of systems where pixel values were available. SNR was affected by the selection of acquisition protocol. Comparisons between different technologies and collation of data will help refine acceptance thresholds and contribute to optimising dose and image quality. (authors)

  1. Rib Radiography versus Chest Computed Tomography in the Diagnosis of Rib Fractures.

    Science.gov (United States)

    Sano, Atsushi

    2018-05-01

     The accurate diagnosis of rib fractures is important in chest trauma. Diagnostic images following chest trauma are usually obtained via chest X-ray, chest computed tomography, or rib radiography. This study evaluated the diagnostic characteristics of rib radiography and chest computed tomography.  Seventy-five rib fracture patients who underwent both chest computed tomography and rib radiography between April 2008 and December 2013 were included. Rib radiographs, centered on the site of pain, were taken from two directions. Chest computed tomography was performed using a 16-row multidetector scanner with 5-mm slice-pitch without overlap, and axial images were visualized in a bone window.  In total, 217 rib fractures were diagnosed in 75 patients. Rib radiography missed 43 rib fractures in 24 patients. The causes were overlap with organs in 15 cases, trivial fractures in 21 cases, and injury outside the imaging range in 7 cases. Left lower rib fractures were often missed due to overlap with the heart, while middle and lower rib fractures were frequently not diagnosed due to overlap with abdominal organs. Computed tomography missed 21 rib fractures in 17 patients. The causes were horizontal fractures in 10 cases, trivial fractures in 9 cases, and insufficient breath holding in 1 case.  In rib radiography, overlap with organs and fractures outside the imaging range were characteristic reasons for missed diagnoses. In chest computed tomography, horizontal rib fractures and insufficient breath holding were often responsible. We should take these challenges into account when diagnosing rib fractures. Georg Thieme Verlag KG Stuttgart · New York.

  2. Computed Tomography and Computed Radiography of late Bronze Age Cremation Urns from Denmark

    DEFF Research Database (Denmark)

    Harvig, Lise Lock; Lynnerup, Niels; Amsgaard Ebsen, Jannie

    2012-01-01

    To improve methods used to study prehistoric cremation rituals, cremation urns from the Danish late Bronze Age were examined using Computed Tomography and Computed Radiography (Digital X-ray). During microexcavation, the digital images were used as registration tool. Our results suggest...

  3. Soft computing techniques in engineering applications

    CERN Document Server

    Zhong, Baojiang

    2014-01-01

    The Soft Computing techniques, which are based on the information processing of biological systems are now massively used in the area of pattern recognition, making prediction & planning, as well as acting on the environment. Ideally speaking, soft computing is not a subject of homogeneous concepts and techniques; rather, it is an amalgamation of distinct methods that confirms to its guiding principle. At present, the main aim of soft computing is to exploit the tolerance for imprecision and uncertainty to achieve tractability, robustness and low solutions cost. The principal constituents of soft computing techniques are probabilistic reasoning, fuzzy logic, neuro-computing, genetic algorithms, belief networks, chaotic systems, as well as learning theory. This book covers contributions from various authors to demonstrate the use of soft computing techniques in various applications of engineering.  

  4. Soft tissue metastases from differentiated thyroid cancer diagnosed by {sup 18}F FDG PET-CT

    Energy Technology Data Exchange (ETDEWEB)

    Califano, Ines; Quildrian, Sergio; Otero, Jose; Coduti, Martin; Califano, Leonardo; Rojas Bilbao, Erica, E-mail: ines.m.califano@gmail.com [Instituto de Oncologia Angel H. Roffo, Universidad de Buenos Aires (Argentina)

    2013-06-15

    Distant metastases of differentiated thyroid cancer are unusual; lung and bones are the most frequently affected sites. Soft tissue metastases (STM) are extremely rare. We describe two cases of patients with differentiated thyroid cancer metastasizing to soft tissues. Both patients had widespread metastatic disease; clinically asymptomatic soft tissue metastases were found by 18-Fluorodeoxyglucose positron emission tomography/computed tomography ({sup 18}F FDG PET-CT), and confirmed by cytological and/or histopathological studies. These findings underscore the ability of {sup 18}F FDG PET-CT in accurately assessing the extent of the disease, as well as the utility of the method to evaluate regions of the body that are not routinely explored. (author)

  5. The clinical application of computed radiography in bedside photography of newborn

    International Nuclear Information System (INIS)

    Peng Sen; Guo Tianchang

    2005-01-01

    Objective: To evaluate the computed radiography in bedside photography of newborn, especially in chest radiography. Methods: Bedside CR images were selected in 100 cases randomly. The exposure parameters were optimized using the large latitude of CR. The details of images were post-processed and adjusted using spatial tuning technique. Then CR photography was compared with conventional X-ray photography. Results: The images acquired with CR had good contrast, high definition, and little distortion, in which the condemned image rate was 1%. While in conventional X-ray photography, the unsuccessful imaging rate is 9%. Conclusion: Bedside computed radiography of new-born, especially the chest imaging, is very helpful to improve image quality and positive rate of the diagnosis. (authors)

  6. Dose optimisation in computed radiography

    International Nuclear Information System (INIS)

    Schreiner-Karoussou, A.

    2005-01-01

    After the installation of computed radiography (CR) systems in three hospitals in Luxembourg a patient dose survey was carried out for three radiographic examinations, thorax, pelvis and lumbar spine. It was found that the patient doses had changed in comparison with the patient doses measured for conventional radiography in the same three hospitals. A close collaboration between the manufacturers of the X-ray installations, the CR imaging systems and the medical physicists led to the discovery that the speed class with which each radiographic examination was to be performed, had been ignored, during installation of the digital imaging systems. A number of procedures were carried out in order to calibrate and program the X-ray installations in conjunction with the CR systems. Following this optimisation procedure, a new patient dose survey was carried out for the three radiographic examinations. It was found that patient doses for the three hospitals were reduced. (authors)

  7. Computer tomography for rare soft tissue tumours of the extremities

    International Nuclear Information System (INIS)

    Boettger, E.; Semerak, M.; Stoltze, D.; Rossak, K.

    1979-01-01

    Five patients with undiagnosed soft tissue masses in the extremities were examined and in two a pathological diagnosis could be made. One was an extensive, invasive fibroma (desmoid) 22 cm long which could be followed from the thigh almost into the pelvis. It was sharply demarkated form the surrounding muscles and of higher density. The second case was a 12 cm long cavernous haemangioma in the semi-membranosus muscle. This was originally hypo-dense, but showed marked increase in its density after the administration of contrast. (orig.) [de

  8. Fabrication of low cost soft tissue prostheses with the desktop 3D printer.

    Science.gov (United States)

    He, Yong; Xue, Guang-huai; Fu, Jian-zhong

    2014-11-27

    Soft tissue prostheses such as artificial ear, eye and nose are widely used in the maxillofacial rehabilitation. In this report we demonstrate how to fabricate soft prostheses mold with a low cost desktop 3D printer. The fabrication method used is referred to as Scanning Printing Polishing Casting (SPPC). Firstly the anatomy is scanned with a 3D scanner, then a tissue casting mold is designed on computer and printed with a desktop 3D printer. Subsequently, a chemical polishing method is used to polish the casting mold by removing the staircase effect and acquiring a smooth surface. Finally, the last step is to cast medical grade silicone into the mold. After the silicone is cured, the fine soft prostheses can be removed from the mold. Utilizing the SPPC method, soft prostheses with smooth surface and complicated structure can be fabricated at a low cost. Accordingly, the total cost of fabricating ear prosthesis is about $30, which is much lower than the current soft prostheses fabrication methods.

  9. Significance of prevertebral soft tissue measurement in cervical spine injuries

    Energy Technology Data Exchange (ETDEWEB)

    Dai Liyang E-mail: lydai@etang.com

    2004-07-01

    Objective: The objective of this study was to evaluate the diagnostic value of prevertebral soft tissue swelling in cervical spine injuries. Materials and methods: A group of 107 consecutive patients with suspected injuries of the cervical vertebrae were reviewed retrospectively to identify the presence of prevertebral soft tissue swelling and to investigate the association of prevertebral soft tissue swelling with the types and degrees of cervical spine injuries. Results: Prevertebral soft tissue swelling occurred in 47 (43.9%) patients. Of the 47 patients, 38 were found with bony injury and nine were without. The statistic difference was significant (P<0.05). No correlation was demonstrated between soft tissue swelling and either the injured level of the cervical vertebrae or the degree of the spinal cord injury (P>0.05). Anterior element injuries in the cervical vertebrae had widening of the prevertebral soft tissue more than posterior element injuries (P<0.05). Conclusion: The diagnostic value of prevertebral soft tissue swelling for cervical spine injuries is significant, but the absence of this sign does not mean that further image evaluation can be spared.

  10. Temperature dependence of postmortem MR quantification for soft tissue discrimination

    Energy Technology Data Exchange (ETDEWEB)

    Zech, Wolf-Dieter; Schwendener, Nicole; Jackowski, Christian [University of Bern, From the Institute of Forensic Medicine, Bern (Switzerland); Persson, Anders; Warntjes, Marcel J. [University of Linkoeping, The Center for Medical Image Science and Visualization (CMIV), Linkoeping (Sweden)

    2015-08-15

    To investigate and correct the temperature dependence of postmortem MR quantification used for soft tissue characterization and differentiation in thoraco-abdominal organs. Thirty-five postmortem short axis cardiac 3-T MR examinations were quantified using a quantification sequence. Liver, spleen, left ventricular myocardium, pectoralis muscle and subcutaneous fat were analysed in cardiac short axis images to obtain mean T1, T2 and PD tissue values. The core body temperature was measured using a rectally inserted thermometer. The tissue-specific quantitative values were related to the body core temperature. Equations to correct for temperature differences were generated. In a 3D plot comprising the combined data of T1, T2 and PD, different organs/tissues could be well differentiated from each other. The quantitative values were influenced by the temperature. T1 in particular exhibited strong temperature dependence. The correction of quantitative values to a temperature of 37 C resulted in better tissue discrimination. Postmortem MR quantification is feasible for soft tissue discrimination and characterization of thoraco-abdominal organs. This provides a base for computer-aided diagnosis and detection of tissue lesions. The temperature dependence of the T1 values challenges postmortem MR quantification. Equations to correct for the temperature dependence are provided. (orig.)

  11. Temperature dependence of postmortem MR quantification for soft tissue discrimination

    International Nuclear Information System (INIS)

    Zech, Wolf-Dieter; Schwendener, Nicole; Jackowski, Christian; Persson, Anders; Warntjes, Marcel J.

    2015-01-01

    To investigate and correct the temperature dependence of postmortem MR quantification used for soft tissue characterization and differentiation in thoraco-abdominal organs. Thirty-five postmortem short axis cardiac 3-T MR examinations were quantified using a quantification sequence. Liver, spleen, left ventricular myocardium, pectoralis muscle and subcutaneous fat were analysed in cardiac short axis images to obtain mean T1, T2 and PD tissue values. The core body temperature was measured using a rectally inserted thermometer. The tissue-specific quantitative values were related to the body core temperature. Equations to correct for temperature differences were generated. In a 3D plot comprising the combined data of T1, T2 and PD, different organs/tissues could be well differentiated from each other. The quantitative values were influenced by the temperature. T1 in particular exhibited strong temperature dependence. The correction of quantitative values to a temperature of 37 C resulted in better tissue discrimination. Postmortem MR quantification is feasible for soft tissue discrimination and characterization of thoraco-abdominal organs. This provides a base for computer-aided diagnosis and detection of tissue lesions. The temperature dependence of the T1 values challenges postmortem MR quantification. Equations to correct for the temperature dependence are provided. (orig.)

  12. Primary hydatid cyst in the soft tissue of the face: An exceptional occurrence

    Directory of Open Access Journals (Sweden)

    Cherry Bansal

    2011-01-01

    Full Text Available To emphasize that solitary hydatid cyst can be localized in the soft tissue and present as a soft tissue mass even in an unusual site like face, we report the case of a 42-year-old male patient presenting with a slowly growing mass in right temporal region. Computed tomography (CT scan showed an encapsulated mass with multiple cysts. Histopathological examination revealed the characteristic findings, which were consistent with soft-tissue hydatid disease. In the absence of visceral organ involvement, this is the first reported case of a primary subcutaneous hydatid cyst in the skin of face in India. In the English literature, only one case of this kind has been reported till date. When imaging methods confirm cystic nature of a swelling, even in unusual sites, one should always keep a possibility of hydatid cyst and manage accordingly during surgery to avoid precipitation of acute anaphylaxis.

  13. New Concepts and Applications in Soft Computing

    CERN Document Server

    Fodor, János; Várkonyi-Kóczy, Annamária

    2013-01-01

                  The book provides a sample of research on the innovative theory and applications of soft computing paradigms.             The idea of Soft Computing was initiated in 1981 when Professor Zadeh published his first paper on soft data analysis and constantly evolved ever since. Professor Zadeh defined Soft Computing as the fusion of the fields of fuzzy logic (FL), neural network theory (NN) and probabilistic reasoning (PR), with the latter subsuming belief networks, evolutionary computing including DNA computing, chaos theory and parts of learning theory into one multidisciplinary system. As Zadeh said the essence of soft computing is that unlike the traditional, hard computing, soft computing is aimed at an accommodation with the pervasive imprecision of the real world. Thus, the guiding principle of soft computing is to exploit the tolerance for imprecision, uncertainty and partial truth to achieve tractability, robustness, low solution cost and better rapport with reality. ...

  14. Physical image quality of computed radiography in mammography system

    International Nuclear Information System (INIS)

    Norriza Mohd Isa; Muhammad Jamal Isa; Wan Muhamad Saridan Wan Hassan; Fatimah Othman

    2013-01-01

    Full-text: Mammography is a screening procedure that mostly used for early detection of breast cancer. In digital imaging system, Computed Radiography is a cost-effective technology that applied indirect conversion detector. The paper presents physical image quality parameter measurements namely modulation transfer function (MTF), normalized noise power spectrum (NNPS) and detective quantum efficiency (DQE) of Computed Radiography in mammography system. MTF was calculated from two different orientations of slanted images of an edge test device and NNPS was estimated using flat-field image. Both images were acquired using a standard mammography beam quality. DQE was determined by applying the MTF and NNPS values into our developed software program. Both orientations have similar DQE characteristics. (author)

  15. Next Generation Tissue Engineering of Orthopedic Soft Tissue-to-Bone Interfaces

    Science.gov (United States)

    Boys, Alexander J.; McCorry, Mary Clare; Rodeo, Scott; Bonassar, Lawrence J.; Estroff, Lara A.

    2017-01-01

    Soft tissue-to-bone interfaces are complex structures that consist of gradients of extracellular matrix materials, cell phenotypes, and biochemical signals. These interfaces, called entheses for ligaments, tendons, and the meniscus, are crucial to joint function, transferring mechanical loads and stabilizing orthopedic joints. When injuries occur to connected soft tissue, the enthesis must be re-established to restore function, but due to structural complexity, repair has proven challenging. Tissue engineering offers a promising solution for regenerating these tissues. This prospective review discusses methodologies for tissue engineering the enthesis, outlined in three key design inputs: materials processing methods, cellular contributions, and biochemical factors. PMID:29333332

  16. Prevalence of bone and soft tissue tumors.

    Science.gov (United States)

    Yücetürk, Güven; Sabah, Dündar; Keçeci, Burçin; Kara, Ahmet Duran; Yalçinkaya, Selçuk

    2011-01-01

    Multidisciplinary approach is a necessity for the appropriate diagnosis and treatment of bone and soft tissue tumors. The Ege University Musculoskeletal Tumor Council offers consultation services to other hospitals in the Aegean region. Since 1988 the Council has met weekly and spent approximately 1,500 hours evaluating almost 6,000 patients with suspected skeletal system tumors. Our objective was to present the data obtained from this patient group. A total of 5,658 patients, suspected to have a musculoskeletal tumor, were evaluated retrospectively. Multiple records of the patients due to multiple attendance to the Council were excluded. The prevalance of the bone and soft tissue tumors in these patients were analysed. Malignant mesenchymal tumors accounted for 39.7% of the total patients, benign tumors for 17%, tumor-like lesions for 17.8% and metastatic carsinomas for 8.6%. Malignant bone tumors were 50.2% and malignant soft tissue tumors were 49.8% of all the sarcomas. Among the malignant bone tumors the most common was osteosarcomas at a rate of 33.6%, followed by Ewing-PNET at 25.5%, chondrosarcomas at 19.4% and haematopoietic tumors at 17.6%. Pleomorphic sarcomas (24.5%), liposarcoma (16.4%), synovial sarcoma (13%) and undifferential sarcomas (8.8%) were the most common types of malignant sof tissue tumors. Benign soft tissue tumors (48%), benign cartilage tumors (28%), giant cell tumor (15%) and osteogenic tumors (9%) were found among the benign tumors. Hemangioma, lipoma, agressive fibromatosis, enchondroma, solitary chondroma and osteoid osteoma were the most common tumors in their groups. Lung (27%), breast (24%), gastrointestinal system (10.5%) and kidney (8.2%) carcinomas were the most common primary sites of the bone metastasis. Turkey still lacks a comprehensive series indicating the incidence and diagnostic distribution of bone and soft tissue tumors. The presented data would add to our knowledge on the specific rates of the bone and soft tissue

  17. Olaratumab for advanced soft tissue sarcoma.

    Science.gov (United States)

    Tobias, Alexander; O'brien, Michael P; Agulnik, Mark

    2017-07-01

    Olaratumab is a humanized IgG1 monoclonal antibody that blocks the platelet-derived growth factor receptor alpha (PDGFRα). Its antagonistic behavior inhibits the receptor's tyrosine kinase activity, thereby, turning off the downstream signaling cascades responsible for soft tissue sarcoma tumorigenesis. In October 2016, olaratumab received Food and Drug Administration (FDA) approval for its use in combination with doxorubicin for treatment of advanced soft tissue sarcoma. Areas covered: This drug profile takes a comprehensive look at the clinical studies leading to FDA approval of olaratumab as well as its safety and efficacy as a front-line treatment option for sarcoma patients. The literature search was primarily conducted using PubMed. Expert commentary: The combination of olaratumab plus doxorubicin has provided a new front-line therapeutic option for soft tissue sarcoma patients. An open-label phase Ib and randomized phase II trial in patients with advanced soft tissue sarcoma demonstrated that the addition of olaratumab to doxorubicin prolonged progression-free survival by 2.5 months and overall survival by 11.8 months when compared to doxorubicin alone. Of importance, this clinically meaningful increase in overall survival did not come at the expense of a significantly greater number of toxicities. A phase III confirmatory trial (ClinicalTrials.gov Identifier NCT02451943) will be completed in 2020.

  18. Comparison of effective atomic numbers of the cancerous and normal kidney tissue

    International Nuclear Information System (INIS)

    Manjunatha, H.C.

    2015-01-01

    The effective atomic number (Z eff ) and electron density (N e ) of normal kidney and cancerous kidney have been computed for total and partial photon interactions by computing the molecular, atomic, and electronic cross section in the wide energy range of 1 keV-100 GeV using WinXCOM. The mean Z eff and N e of normal kidney and cancerous kidney in the various energy ranges and for total and partial photon interactions are tabulated. The variation of effective N e with energy is shown graphically for all photon interactions. In addition to this computer tomography (CT), numbers of normal kidney and cancerous kidney for photon interaction and energy absorption is also computed. The role of Z eff in the dual-energy dividing radiography is also discussed. The values of Z eff and N e for cancerous kidney are higher than normal kidney. This is due to the levels of elements K, Ca, Fe, Ni, and Se are lower and those of the elements Ti, Co, Zn, As, and Cd are higher in the cancer tissue of kidney than those observed in the normal tissue. The soft tissue and cancerous tissue are very similar, but their atomic number differs. The cancerous tissue exhibits a higher Z eff than the normal tissue. This fact helps in the dual-energy dividing radiography which enables to improve the diagnosis of the kidney cancer. Hence, the computed values may be useful in the diagnosis of the kidney cancer. CT numbers for normal kidney are higher than cancerous kidney. (author)

  19. Tissue Friendly Pendulum: Soft Liner to prevent Tissue Irritation

    Directory of Open Access Journals (Sweden)

    Siddharth Shashidhar Revankar

    2014-01-01

    Full Text Available Palatal mucosal irritation is commonly encountered with the Pendulum appliance. The efficiency of soft liners in reducing tissue irritation has been well documented in the field of prosthodontics. The following article describes an innovative technique where soft liner can be used to reduce palatal mucosal irritation caused by pendulum appliance.

  20. Vascularization of soft tissue engineering constructs

    DEFF Research Database (Denmark)

    Pimentel Carletto, Rodrigo

    nanotechnology-based paradigm for engineering vascularised liver tissue for transplantation”) and the Danish National Research Foundation and Villum Foundation’s Center for Intelligent Drug delivery and sensing Using microcontainers and Nanomechanics (Danish National Research Foundation (DNRF122).......Vascularization is recognized to be the biggest challenge for the fabrication of tissues and finally, organs in vitro. So far, several fabrication techniques have been proposed to create a perfusable vasculature within hydrogels, however, the vascularization and perfusion of hydrogels...... with mechanical properties in the range of soft tissues has not been fully achieved. My project focused on the fabrication and the active perfusion of hydrogel constructs with multi-dimensional vasculature and controlled mechanical properties targeting soft tissues. Specifically, the initial part of the research...

  1. Heavy-ion radiography and heavy-ion computed tomography

    International Nuclear Information System (INIS)

    Fabrikant, J.I.; Holley, W.R.; McFarland, E.W.; Tobias, C.a.

    1982-02-01

    Heavy-ion projection and CT radiography is being developed into a safe, low-dose, noninvasive radiological procedure that can quantitate and image small density differences in human tissues. The applications to heavy-ion mammography and heavy-ion CT imaging of the brain in clinical patients suggest their potential value in cancer diagnosis

  2. 'Soft Technique' still in use in chest radiography - Pros and Cons

    International Nuclear Information System (INIS)

    Slavchev, A.; Manolov, I.

    2004-01-01

    In recent years the number of the radiological equipment throughout the country grew immensely. It encounters old installations, new modern devices as well as and this in ever rising degree mainly imported second-hand machines or recycled ones. It is well known that the performance of a medical device and particularly of a X-ray one depends on many factors, some of them being of paramount importance for its life cycle: factory-side set characteristics, mode of operation, daily use (load), quality of service, etc. The 'soft' radiography technique (low radiation - 50 to 85 kV), due to certain conjuncture considerations used at large in this country, is totally contradicting the European criteria for image quality. Something more, it seems to be one of the most essential reasons for the higher radiation exposure of the patients and the staff. The often advocated argument to save the equipment by means of the 'soft technique' is not acceptable and taking into account the present nominal values of the basic radiological parameters/ components has categorically to be rejected. The cardinal task of the engaged service staff consists in installing/guaranteeing the technological conditions fully to meet the European norms whereas the inspector has to monitor, analyze, compare and if necessary to undertake measures to obtain this compliance. It is a matter not only of reliability and availability, the purpose consists rather in a consistent good image quality. The application of the 'hard technique' (high radiation) for chest radiography ensures not only a more complete and more precise diagnostic information but also helps in reducing the irradiation of the patient and the staff and in this manner contributes to lower the medical risk and to raise the medical diagnostic care on a higher level. (authors)

  3. Computed tomography angiography reveals stenosis and aneurysmal dilation of an aberrant right subclavian artery causing systemic blood pressure misreading in an old Pekinese dog.

    Science.gov (United States)

    Kim, Jaehwan; Eom, Kidong; Yoon, Hakyoung

    2017-06-16

    A 14-year-old dog weighing 4 kg presented with hypotension only in the right forelimb. Thoracic radiography revealed a round soft tissue opacity near the aortic arch and below the second thoracic vertebra on a lateral view. Three-dimensional computed tomography angiography clearly revealed stenosis and aneurysmal dilation of an aberrant right subclavian artery. Stenosis and aneurysm of an aberrant subclavian artery should be included as a differential diagnosis in dogs showing a round soft tissue opacity near the aortic arch and below the thoracic vertebra on the lateral thoracic radiograph.

  4. Soft Tissue Strain Rates in Side-Blast Incidents

    Science.gov (United States)

    2014-11-02

    increase of strain rate is known to cause the stiffening of soft connective tissues ( Haut and Haut 1997 [49]; Panjabi et al. 1998 [50]; Crisco et al...Réseau Québécois de Calcul de Haute Performance, with a peak compute performance of 27 596 GFlops). Figure 2: Torso motion imposed in the model...Yan YP. 2003. Mechanical properties of nasal fascia and periosteum. Clinical Biomechanics. 18:760-764. [49] Haut TL, Haut RC. 1997. The state of

  5. Soft-tissue mineralization in Werner syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Leone, Antonio; Costantini, Alessandro Maria; Brigida, Raffaela; Antoniol, Onorina Monica; Bonomo, Lorenzo [Universita Cattolica School of Medicine, Department of Radiology, Rome (Italy); Antonelli-Incalzi, Raffaele [Universita Cattolica School of Medicine, Department of Geriatrics, Rome (Italy)

    2005-01-01

    Werner syndrome is a rare autosomal recessive disorder characterized by clinical signs of premature aging, short stature, scleroderma-like skin changes, endocrine abnormalities, cataracts, and an increased incidence of malignancies. We report on a 48-year-old woman with Werner syndrome associated with intracranial meningiomas who had extensive musculoskeletal manifestations including osteoporosis of the extremities, extensive tendinopathy about the ankles, osteomyelitis of the phalanges of the first left toe, abundant soft-tissue calcification, and two dense ossified soft-tissue masses, with cortical bone and trabeculae arising from the posterosuperior aspect of the calcanei and extending into Kager fat pads. A review of previous descriptions of the radiological abnormalities of Werner syndrome indicates that the presence of soft-tissue calcifications has either not been noted or been mentioned only briefly. Moreover, there is no mention of bony masses associated with Werner syndrome in the world literature, and this would appear to be the first report of this kind. (orig.)

  6. Engineering applications of soft computing

    CERN Document Server

    Díaz-Cortés, Margarita-Arimatea; Rojas, Raúl

    2017-01-01

    This book bridges the gap between Soft Computing techniques and their applications to complex engineering problems. In each chapter we endeavor to explain the basic ideas behind the proposed applications in an accessible format for readers who may not possess a background in some of the fields. Therefore, engineers or practitioners who are not familiar with Soft Computing methods will appreciate that the techniques discussed go beyond simple theoretical tools, since they have been adapted to solve significant problems that commonly arise in such areas. At the same time, the book will show members of the Soft Computing community how engineering problems are now being solved and handled with the help of intelligent approaches. Highlighting new applications and implementations of Soft Computing approaches in various engineering contexts, the book is divided into 12 chapters. Further, it has been structured so that each chapter can be read independently of the others.

  7. MRI evaluation of soft tissue hydatid disease

    International Nuclear Information System (INIS)

    Garcia-Diez, A.I.; Ros Mendoza, L.H.; Villacampa, V.M.; Cozar, M.; Fuertes, M.I.

    2000-01-01

    Infestation in soft tissue by Echinococcus granulosus is not a common disease, and its diagnosis is based on clinical, laboratory data and radiological findings. The aim of our retrospective study is to give an overview of the different signs and patterns shown by MRI that can be useful in characterizing soft tissue hydatid disease. The MRI images obtained in seven patients with soft tissue and subcutaneous hydatidosis were reviewed. Typical signs of hydatidosis were multivesicular lesions with or without hypointense peripheral ring (''rim sign''). Related to the presence and absence, respectively, of viable scolices in the microscopic exam, daughter cysts were presented either as high signal intensity or low signal intensity on T2-weighted images. Low-intensity detached layers within the cyst and peripheral enhancement with gadolinium-DTPA were also presented. Atypical signs were presented in an infected muscular cyst, a subcutaneous unilocular cyst and several unilocular cysts. Knowledge of the different patterns in MRI of soft tissue hydatid disease can be useful in diagnosing this entity. We observed that the ''rim sign'' is not as common as in other locations, and in addition, MRI seems to be of assistance when evaluating the vitality of the cysts. (orig.)

  8. Computational model of soft tissues in the human upper airway.

    Science.gov (United States)

    Pelteret, J-P V; Reddy, B D

    2012-01-01

    This paper presents a three-dimensional finite element model of the tongue and surrounding soft tissues with potential application to the study of sleep apnoea and of linguistics and speech therapy. The anatomical data was obtained from the Visible Human Project, and the underlying histological data was also extracted and incorporated into the model. Hyperelastic constitutive models were used to describe the material behaviour, and material incompressibility was accounted for. An active Hill three-element muscle model was used to represent the muscular tissue of the tongue. The neural stimulus for each muscle group was determined through the use of a genetic algorithm-based neural control model. The fundamental behaviour of the tongue under gravitational and breathing-induced loading is investigated. It is demonstrated that, when a time-dependent loading is applied to the tongue, the neural model is able to control the position of the tongue and produce a physiologically realistic response for the genioglossus.

  9. Extremity exams optimization for computed radiography; Otimizacao de exames de extremidade para radiologia computadorizada

    Energy Technology Data Exchange (ETDEWEB)

    Pavan, Ana Luiza M.; Alves, Allan Felipe F.; Velo, Alexandre F.; Miranda, Jose Ricardo A., E-mail: analuiza@ibb.unesp.br [Universidade Estadual Paulista Julio de Mesquita Filho (UNESP), Botucatu, SP (Brazil). Instituto de Biociencias. Departamento de Fisica e Biofisica; Pina, Diana R. [Universidade Estadual Paulista Julio de Mesquita Filho (UNESP), Botucatu, SP (Brazil). Faculdade de Medicina. Departamento de Doencas Tropicais e Diagnostico por Imagem

    2013-08-15

    The computed radiography (CR) has become the most used device for image acquisition, since its introduction in the 80s. The detection and early diagnosis, obtained through CR examinations, are important for the successful treatment of diseases of the hand. However, the norms used for optimization of these images are based on international protocols. Therefore, it is necessary to determine letters of radiographic techniques for CR system, which provides a safe medical diagnosis, with doses as low as reasonably achievable. The objective of this work is to develop an extremity homogeneous phantom to be used in the calibration process of radiographic techniques. In the construction process of the simulator, it has been developed a tissues' algorithm quantifier using Matlab®. In this process the average thickness was quantified from bone and soft tissues in the region of the hand of an anthropomorphic simulator as well as the simulators' material thickness corresponding (aluminum and Lucite) using technique of mask application and removal Gaussian histogram corresponding to tissues of interest. The homogeneous phantom was used to calibrate the x-ray beam. The techniques were implemented in a calibrated hand anthropomorphic phantom. The images were evaluated by specialists in radiology by the method of VGA. Skin entrance surface doses were estimated (SED) corresponding to each technique obtained with their respective tube charge. The thicknesses of simulators materials that constitute the homogeneous phantom determined in this study were 19.01 mm of acrylic and 0.81 mm of aluminum. A better picture quality with doses as low as reasonably achievable decreased dose and tube charge around 53.35% and 37.78% respectively, compared normally used by radiology diagnostic routine clinical of HCFMB-UNESP. (author)

  10. Comparison of Diagnostic Accuracy of Radiation Dose-Equivalent Radiography, Multidetector Computed Tomography and Cone Beam Computed Tomography for Fractures of Adult Cadaveric Wrists.

    Science.gov (United States)

    Neubauer, Jakob; Benndorf, Matthias; Reidelbach, Carolin; Krauß, Tobias; Lampert, Florian; Zajonc, Horst; Kotter, Elmar; Langer, Mathias; Fiebich, Martin; Goerke, Sebastian M

    2016-01-01

    To compare the diagnostic accuracy of radiography, to radiography equivalent dose multidetector computed tomography (RED-MDCT) and to radiography equivalent dose cone beam computed tomography (RED-CBCT) for wrist fractures. As study subjects we obtained 10 cadaveric human hands from body donors. Distal radius, distal ulna and carpal bones (n = 100) were artificially fractured in random order in a controlled experimental setting. We performed radiation dose equivalent radiography (settings as in standard clinical care), RED-MDCT in a 320 row MDCT with single shot mode and RED-CBCT in a device dedicated to musculoskeletal imaging. Three raters independently evaluated the resulting images for fractures and the level of confidence for each finding. Gold standard was evaluated by consensus reading of a high-dose MDCT. Pooled sensitivity was higher in RED-MDCT with 0.89 and RED-MDCT with 0.81 compared to radiography with 0.54 (P = radiography (P radiography. Readers are more confident in their reporting with the cross sectional modalities. Dose equivalent cross sectional computed tomography of the wrist could replace plain radiography for fracture diagnosis in the long run.

  11. Toward high-speed 3D nonlinear soft tissue deformation simulations using Abaqus software.

    Science.gov (United States)

    Idkaidek, Ashraf; Jasiuk, Iwona

    2015-12-01

    We aim to achieve a fast and accurate three-dimensional (3D) simulation of a porcine liver deformation under a surgical tool pressure using the commercial finite element software Abaqus. The liver geometry is obtained using magnetic resonance imaging, and a nonlinear constitutive law is employed to capture large deformations of the tissue. Effects of implicit versus explicit analysis schemes, element type, and mesh density on computation time are studied. We find that Abaqus explicit and implicit solvers are capable of simulating nonlinear soft tissue deformations accurately using first-order tetrahedral elements in a relatively short time by optimizing the element size. This study provides new insights and guidance on accurate and relatively fast nonlinear soft tissue simulations. Such simulations can provide force feedback during robotic surgery and allow visualization of tissue deformations for surgery planning and training of surgical residents.

  12. A novel soft tissue prediction methodology for orthognathic surgery based on probabilistic finite element modelling.

    Science.gov (United States)

    Knoops, Paul G M; Borghi, Alessandro; Ruggiero, Federica; Badiali, Giovanni; Bianchi, Alberto; Marchetti, Claudio; Rodriguez-Florez, Naiara; Breakey, Richard W F; Jeelani, Owase; Dunaway, David J; Schievano, Silvia

    2018-01-01

    Repositioning of the maxilla in orthognathic surgery is carried out for functional and aesthetic purposes. Pre-surgical planning tools can predict 3D facial appearance by computing the response of the soft tissue to the changes to the underlying skeleton. The clinical use of commercial prediction software remains controversial, likely due to the deterministic nature of these computational predictions. A novel probabilistic finite element model (FEM) for the prediction of postoperative facial soft tissues is proposed in this paper. A probabilistic FEM was developed and validated on a cohort of eight patients who underwent maxillary repositioning and had pre- and postoperative cone beam computed tomography (CBCT) scans taken. Firstly, a variables correlation assessed various modelling parameters. Secondly, a design of experiments (DOE) provided a range of potential outcomes based on uniformly distributed input parameters, followed by an optimisation. Lastly, the second DOE iteration provided optimised predictions with a probability range. A range of 3D predictions was obtained using the probabilistic FEM and validated using reconstructed soft tissue surfaces from the postoperative CBCT data. The predictions in the nose and upper lip areas accurately include the true postoperative position, whereas the prediction under-estimates the position of the cheeks and lower lip. A probabilistic FEM has been developed and validated for the prediction of the facial appearance following orthognathic surgery. This method shows how inaccuracies in the modelling and uncertainties in executing surgical planning influence the soft tissue prediction and it provides a range of predictions including a minimum and maximum, which may be helpful for patients in understanding the impact of surgery on the face.

  13. CT Imaging of facial trauma. The role of different types of reconstruction. Part II - soft tissues

    International Nuclear Information System (INIS)

    Myga-Porosilo, J.; Sraga, W.; Borowiak, H.; Jackowska, Z.; Kluczewska, E.; Skrzelewski, S.

    2011-01-01

    Background: Injury to facial soft tissues as a complication of skeleton fractures is an important problem among patients with facial trauma. The aim of this work was to assess the value of multiplanar and three-dimensional (3D) reconstruction computed tomography (CT) images obtained by using multi-detector row technology in spiral data acquisition in patients with facial injuries of soft tissue. Material/Methods: Sixty-seven patients diagnosed with injury to the facial skeleton underwent a CT scan with the use of GE Hispeed Qx/i scanner. For each patient: a two-dimensional (2D) multiplanar reconstruction (MPR), maximum intensity projection (MIP), and 3D volume rendering (VR) were conducted. Post-injury lesions of soft tissues were assessed. During the assessment of the post-injury lesions of soft tissues, the following features were evaluated: Extra ocular muscle and fat tissue herniation through fractures in the medial and inferior orbital walls. Fluid in the sinuses and in the nasal cavity. Subcutaneous tissue emphysema. Results: For subcutaneous emphysema and sinus fluid imaging, both the axial and the 2D image reconstruction proved comparably effective. However, 2D reconstructions were superior to transverse plane images with regard to herniations into fractures of the inferior orbital wall. 3D reconstruction has no importance in diagnosing soft tissue injuries. Conclusions: Multiplanar CT reconstructions increase the effectiveness of imaging of orbital tissue herniations, especially in case of fractures in the inferior orbital wall. In suspected soft tissue herniations, as well as prior to surgical treatment, spiral CT with 2D multiplanar reconstructions should be the method of choice. (authors)

  14. Soft-tissue metastasis revealing a pancreatic adenocarcinoma: One ...

    African Journals Online (AJOL)

    Soft tissue metastases from pancreatic adenocarcinoma are rare lesions and can be the source of diagnostic confusion both clinically and pathologically. To our knowledge, one patient has been reported on with soft tissue lesions that ultimately disclose a pancreatic adenocarcinoma. We report here on a patient who ...

  15. Angiofibroma of soft tissue: clinicopathologic study of 2 cases of a recently characterized benign soft tissue tumor.

    Science.gov (United States)

    Zhao, Ming; Sun, Ke; Li, Changshui; Zheng, Jiangjiang; Yu, Jingjing; Jin, Jie; Xia, Wenping

    2013-01-01

    Angiofibroma of soft tissue is a very recently characterized, histologically distinctive benign mesenchymal neoplasm of unknown cellular origin composed of 2 principal components, the spindle cell component and very prominent stromal vasculatures. It usually occurs in middle-aged adults, with a female predominance. Herein, we describe the clinical and pathologic details of 2 other examples of this benign tumor. Both patients were middle-aged male and presented with a slow-growing, painless mass located in the deep-seated soft tissue of thigh and left posterior neck region, respectively. Grossly, both tumors were well-demarcated, partial encapsulated of a grayish-white color with firm consistence. Histologically, one case showed morphology otherwise identical to those have been described before, whereas the other case showed in areas being more cellular than most examples of this subtype tumor had, with the lesional cells frequently exhibiting short fascicular, vaguely storiform and occasionally swirling arrangements, which posed a challenging differential diagnosis. Immunostains performed on both tumors did not confirm any specific cell differentiation with lesional cells only reactive for vimentin and focally desmin and negative for all the other markers tested. This report serves to broaden the morphologic spectrum of angiofibroma of soft tumor. Awareness of this tumor is important to prevent misdiagnosis as other more aggressive soft tissue tumor.

  16. Soft Computing Applications : Proceedings of the 5th International Workshop Soft Computing Applications

    CERN Document Server

    Fodor, János; Várkonyi-Kóczy, Annamária; Dombi, Joszef; Jain, Lakhmi

    2013-01-01

                    This volume contains the Proceedings of the 5thInternational Workshop on Soft Computing Applications (SOFA 2012).                                The book covers a broad spectrum of soft computing techniques, theoretical and practical applications employing knowledge and intelligence to find solutions for world industrial, economic and medical problems. The combination of such intelligent systems tools and a large number of applications introduce a need for a synergy of scientific and technological disciplines in order to show the great potential of Soft Computing in all domains.                   The conference papers included in these proceedings, published post conference, were grouped into the following area of research: ·         Soft Computing and Fusion Algorithms in Biometrics, ·         Fuzzy Theory, Control andApplications, ·         Modelling and Control Applications, ·         Steps towa...

  17. Thermal-mechanical deformation modelling of soft tissues for thermal ablation.

    Science.gov (United States)

    Li, Xin; Zhong, Yongmin; Jazar, Reza; Subic, Aleksandar

    2014-01-01

    Modeling of thermal-induced mechanical behaviors of soft tissues is of great importance for thermal ablation. This paper presents a method by integrating the heating process with thermal-induced mechanical deformations of soft tissues for simulation and analysis of the thermal ablation process. This method combines bio-heat transfer theories, constitutive elastic material law under thermal loads as well as non-rigid motion dynamics to predict and analyze thermal-mechanical deformations of soft tissues. The 3D governing equations of thermal-mechanical soft tissue deformation are discretized by using the finite difference scheme and are subsequently solved by numerical algorithms. Experimental results show that the proposed method can effectively predict the thermal-induced mechanical behaviors of soft tissues, and can be used for the thermal ablation therapy to effectively control the delivered heat energy for cancer treatment.

  18. A novel method for soft tissue retraction during periapical surgery using 3D technology: a case report.

    Science.gov (United States)

    Patel, S; Aldowaisan, A; Dawood, A

    2017-08-01

    This case report describes a new approach to isolation and soft tissue retraction during endodontic surgery using cone-beam computed tomography (CBCT), computer-aided design (CAD) and three-dimensional (3D) printing. A 53-year-old patient presented for endodontic treatment of her maxillary left central incisor. It was decided to treat this tooth with a microsurgical approach. The data from the diagnostic CBCT scan were also used to make a physical model of the operative site, and CAD software was used to design a soft tissue retractor to be used during the patient's surgery. A custom retractor was then fabricated using a 3D printer. The custom-made retractor enhanced visualization and soft tissue handling during the patient's surgery. The patient was asymptomatic at a 1-year review. No abnormalities were detected during her clinical examination, and radiographic examination revealed complete healing of the surgical site. The significance of proper soft tissue retraction in periapical microsurgery is underemphasized. Geometric data from CBCT scans may be harvested for a variety of uses, adding value to the examination. 3D printing is a promising technology that may potentially have many uses in endodontic surgery. © 2016 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  19. Updated Lagrangian finite element formulations of various biological soft tissue non-linear material models: a comprehensive procedure and review.

    Science.gov (United States)

    Townsend, Molly T; Sarigul-Klijn, Nesrin

    2016-01-01

    Simplified material models are commonly used in computational simulation of biological soft tissue as an approximation of the complicated material response and to minimize computational resources. However, the simulation of complex loadings, such as long-duration tissue swelling, necessitates complex models that are not easy to formulate. This paper strives to offer the updated Lagrangian formulation comprehensive procedure of various non-linear material models for the application of finite element analysis of biological soft tissues including a definition of the Cauchy stress and the spatial tangential stiffness. The relationships between water content, osmotic pressure, ionic concentration and the pore pressure stress of the tissue are discussed with the merits of these models and their applications.

  20. Fat-containing soft-tissue masses in children.

    Science.gov (United States)

    Sheybani, Elizabeth F; Eutsler, Eric P; Navarro, Oscar M

    2016-12-01

    The diagnosis of soft-tissue masses in children can be difficult because of the frequently nonspecific clinical and imaging characteristics of these lesions. However key findings on imaging can aid in diagnosis. The identification of macroscopic fat within a soft-tissue mass narrows the differential diagnosis considerably and suggests a high likelihood of a benign etiology in children. Fat can be difficult to detect with sonography because of the variable appearance of fat using this modality. Fat is easier to recognize using MRI, particularly with the aid of fat-suppression techniques. Although a large portion of fat-containing masses in children are adipocytic tumors, a variety of other tumors and mass-like conditions that contain fat should be considered by the radiologist confronted with a fat-containing mass in a child. In this article we review the sonographic and MRI findings in the most relevant fat-containing soft-tissue masses in the pediatric age group, including adipocytic tumors (lipoma, angiolipoma, lipomatosis, lipoblastoma, lipomatosis of nerve, and liposarcoma); fibroblastic/myofibroblastic tumors (fibrous hamartoma of infancy and lipofibromatosis); vascular anomalies (involuting hemangioma, intramuscular capillary hemangioma, phosphate and tensin homologue (PTEN) hamartoma of soft tissue, fibro-adipose vascular anomaly), and other miscellaneous entities, such as fat necrosis and epigastric hernia.

  1. MRI evaluation of soft tissue hydatid disease

    Energy Technology Data Exchange (ETDEWEB)

    Garcia-Diez, A.I.; Ros Mendoza, L.H.; Villacampa, V.M.; Cozar, M.; Fuertes, M.I. [Dept. of Radiology, Hospital Miguel Servet, Zaragoza (Spain)

    2000-03-01

    Infestation in soft tissue by Echinococcus granulosus is not a common disease, and its diagnosis is based on clinical, laboratory data and radiological findings. The aim of our retrospective study is to give an overview of the different signs and patterns shown by MRI that can be useful in characterizing soft tissue hydatid disease. The MRI images obtained in seven patients with soft tissue and subcutaneous hydatidosis were reviewed. Typical signs of hydatidosis were multivesicular lesions with or without hypointense peripheral ring (''rim sign''). Related to the presence and absence, respectively, of viable scolices in the microscopic exam, daughter cysts were presented either as high signal intensity or low signal intensity on T2-weighted images. Low-intensity detached layers within the cyst and peripheral enhancement with gadolinium-DTPA were also presented. Atypical signs were presented in an infected muscular cyst, a subcutaneous unilocular cyst and several unilocular cysts. Knowledge of the different patterns in MRI of soft tissue hydatid disease can be useful in diagnosing this entity. We observed that the ''rim sign'' is not as common as in other locations, and in addition, MRI seems to be of assistance when evaluating the vitality of the cysts. (orig.)

  2. Fat-containing soft-tissue masses in children

    Energy Technology Data Exchange (ETDEWEB)

    Sheybani, Elizabeth F. [University of Toronto, Department of Medical Imaging, Toronto, ON (Canada); The Hospital for Sick Children, Department of Diagnostic Imaging, Toronto, ON (Canada); Washington University School of Medicine, Mallinckrodt Institute of Radiology, St. Louis, MO (United States); Eutsler, Eric P. [Washington University School of Medicine, Mallinckrodt Institute of Radiology, St. Louis, MO (United States); Navarro, Oscar M. [University of Toronto, Department of Medical Imaging, Toronto, ON (Canada); The Hospital for Sick Children, Department of Diagnostic Imaging, Toronto, ON (Canada)

    2016-12-15

    The diagnosis of soft-tissue masses in children can be difficult because of the frequently nonspecific clinical and imaging characteristics of these lesions. However key findings on imaging can aid in diagnosis. The identification of macroscopic fat within a soft-tissue mass narrows the differential diagnosis considerably and suggests a high likelihood of a benign etiology in children. Fat can be difficult to detect with sonography because of the variable appearance of fat using this modality. Fat is easier to recognize using MRI, particularly with the aid of fat-suppression techniques. Although a large portion of fat-containing masses in children are adipocytic tumors, a variety of other tumors and mass-like conditions that contain fat should be considered by the radiologist confronted with a fat-containing mass in a child. In this article we review the sonographic and MRI findings in the most relevant fat-containing soft-tissue masses in the pediatric age group, including adipocytic tumors (lipoma, angiolipoma, lipomatosis, lipoblastoma, lipomatosis of nerve, and liposarcoma); fibroblastic/myofibroblastic tumors (fibrous hamartoma of infancy and lipofibromatosis); vascular anomalies (involuting hemangioma, intramuscular capillary hemangioma, phosphate and tensin homologue (PTEN) hamartoma of soft tissue, fibro-adipose vascular anomaly), and other miscellaneous entities, such as fat necrosis and epigastric hernia. (orig.)

  3. Development of computer assisted learning program using cone beam projection for head radiography

    International Nuclear Information System (INIS)

    Nakazeko, Kazuma; Araki, Misao; Kajiwara, Hironori; Watanabe, Hiroyuki; Kuwayama, Jun; Karube, Shuhei; Hashimoto, Takeyuki; Shinohara, Hiroyuki

    2012-01-01

    We present a computer assisted learning (CAL) program to simulate head radiography. The program provides cone beam projections of a target volume, simulating three-dimensional computed tomography (CT) of a head phantom. The generated image is 512 x 512 x 512 pixels with each pixel 0.6 mm on a side. The imaging geometry, such as X-ray tube orientation and phantom orientation, can be varied. The graphical user interface (GUI) of the CAL program allows the study of the effects of varying the imaging geometry; each simulated projection image is shown quickly in an adjoining window. Simulated images with an assigned geometry were compared with the image obtained using the standard geometry in clinical use. The accuracy of the simulated image was verified through comparison with the image acquired using radiography of the head phantom, subsequently processed with a computed radiography system (CR image). Based on correlation coefficient analysis and visual assessment, it was concluded that the CAL program can satisfactorily simulate the CR image. Therefore, it should be useful for the training of head radiography. (author)

  4. Dermal fillers for facial soft tissue augmentation.

    Science.gov (United States)

    Dastoor, Sarosh F; Misch, Carl E; Wang, Hom-Lay

    2007-01-01

    Nowadays, patients are demanding not only enhancement to their dental (micro) esthetics, but also their overall facial (macro) esthetics. Soft tissue augmentation via dermal filling agents may be used to correct facial defects such as wrinkles caused by age, gravity, and trauma; thin lips; asymmetrical facial appearances; buccal fold depressions; and others. This article will review the pathogenesis of facial wrinkles, history, techniques, materials, complications, and clinical controversies regarding dermal fillers for soft tissue augmentation.

  5. Pediatric rhabdomyosarcomas and nonrhabdomyosarcoma soft tissue sarcoma

    OpenAIRE

    Agarwala Sandeep

    2006-01-01

    Tumors arising from the soft tissues are uncommon in children, accounting for about 6% of all childhood malignancies. More than half (53%) of these originate from the striated muscles and are called rhabdomyosarcomas (RMS) the remaining are nonrhabdomyosarcoma soft tissue sarcomas (NRSTS). Almost two-thirds of RMS cases are diagnosed in children < 6 years of age. They can arise at varied locations like the head and neck region, genitourinary tract, extremities, trunk and retrope...

  6. Studies on the Fuji computed radiography depended on the panoramic radiography

    International Nuclear Information System (INIS)

    Nakamura, Satoshi; Shiota, Satoru; Takazawa, Kazuyoshi; Yoshida, Toru; Takagi, Yoshiko; Funamoto, Choichiro

    1986-01-01

    The Fuji Computed Radiography (FCR) developed recently involves the following procedures; photography in the same way as the hitherto radiography, printing auto imaging plate of photostimulable phospher, conversion to electric signals, and recording reproduced images by computerization. Highly valuable images for diagnoses in the medical field have already been obtained by the FCR. Then, we attempted to study FCR images panoramically radiographed for jaw lesions in the field of oral surgery. Method for study: As the samples to be studied, the selected subjects were cases of periodontal diseases, fracture of the jaw, odontogenic cyst and tumor, etc. In the present study the FCR images of panoramic radiography were compared with hitherto panoramic flat radiograms. Result of study: Although the images of the FCR vary depending on the methods of treatment, that is, on how gradient processing and spatial frequency enhancement are, the method of purpose-fitting treatment provided diagnostically significant images for grasping bone lesions. The images obtained from this FCR permitted us to grasp more distinctly condition of alveolar bone resorption in periodontal diseases, running of minute fracture lines in fracture of the jaw, and characteristic images of bone resorption in odontogenic cysts and tumor, etc. Thus the images of the FCR are highly useful in diagnosing bone lesions, but granularity of the images themselves have still been questioned, and additionally the images vary depending on the methods of gradient processing and spatial frequency enhancement. Therefore further repeat studies are probably needed for these questions. (author)

  7. Fibre-Matrix Interaction in Soft Tissue

    International Nuclear Information System (INIS)

    Guo, Zaoyang

    2010-01-01

    Although the mechanical behaviour of soft tissue has been extensively studied, the interaction between the collagen fibres and the ground matrix has not been well understood and is therefore ignored by most constitutive models of soft tissue. In this paper, the human annulus fibrosus is used as an example and the potential fibre-matrix interaction is identified by careful investigation of the experimental results of biaxial and uniaxial testing of the human annulus fibrosus. First, the uniaxial testing result of the HAF along the axial direction is analysed and it is shown that the mechanical behaviour of the ground matrix can be well simulated by the incompressible neo-Hookean model when the collagen fibres are all under contraction. If the collagen fibres are stretched, the response of the ground matrix can still be described by the incompressible neo-Hookean model, but the effective stiffness of the matrix depends on the fibre stretch ratio. This stiffness can be more than 10 times larger than the one obtained with collagen fibres under contraction. This phenomenon can only be explained by the fibre-matrix interaction. Furthermore, we find that the physical interpretation of this interaction includes the inhomogeneity of the soft tissue and the fibre orientation dispersion. The dependence of the tangent stiffness of the matrix on the first invariant of the deformation tensor can also be explained by the fibre orientation dispersion. The significant effect of the fibre-matrix interaction strain energy on mechanical behaviour of the soft tissue is also illustrated by comparing some simulation results.

  8. Assessing the quality of force feedback in soft tissue simulation.

    Science.gov (United States)

    Basafa, Ehsan; Sefati, Shahin; Okamura, Allison M

    2011-01-01

    Many types of deformable models have been proposed for simulation of soft tissue in surgical simulators, but their realism in comparison to actual tissue is rarely assessed. In this paper, a nonlinear mass-spring model is used for realtime simulation of deformable soft tissues and providing force feedback to a human operator. Force-deformation curves of real soft tissue samples were obtained experimentally, and the model was tuned accordingly. To test the realism of the model, we conducted two human-user experiments involving palpation with a rigid probe. First, in a discrimination test, users identified the correct category of real and virtual tissue better than chance, and tended to identify the tissues as real more often than virtual. Second, users identified real and virtual tissues by name, after training on only real tissues. The sorting accuracy was the same for both real and virtual tissues. These results indicate that, despite model limitations, the simulation could convey the feel of touching real tissues. This evaluation approach could be used to compare and validate various soft-tissue simulators.

  9. Real-time deformation of human soft tissues: A radial basis meshless 3D model based on Marquardt's algorithm.

    Science.gov (United States)

    Zhou, Jianyong; Luo, Zu; Li, Chunquan; Deng, Mi

    2018-01-01

    When the meshless method is used to establish the mathematical-mechanical model of human soft tissues, it is necessary to define the space occupied by human tissues as the problem domain and the boundary of the domain as the surface of those tissues. Nodes should be distributed in both the problem domain and on the boundaries. Under external force, the displacement of the node is computed by the meshless method to represent the deformation of biological soft tissues. However, computation by the meshless method consumes too much time, which will affect the simulation of real-time deformation of human tissues in virtual surgery. In this article, the Marquardt's Algorithm is proposed to fit the nodal displacement at the problem domain's boundary and obtain the relationship between surface deformation and force. When different external forces are applied, the deformation of soft tissues can be quickly obtained based on this relationship. The analysis and discussion show that the improved model equations with Marquardt's Algorithm not only can simulate the deformation in real-time but also preserve the authenticity of the deformation model's physical properties. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. 4th World Conference on Soft Computing

    CERN Document Server

    Abbasov, Ali; Yager, Ronald; Shahbazova, Shahnaz; Reformat, Marek

    2016-01-01

    This book reports on advanced theories and cutting-edge applications in the field of soft computing. The individual chapters, written by leading researchers, are based on contributions presented during the 4th World Conference on Soft Computing, held May 25-27, 2014, in Berkeley. The book covers a wealth of key topics in soft computing, focusing on both fundamental aspects and applications. The former include fuzzy mathematics, type-2 fuzzy sets, evolutionary-based optimization, aggregation and neural networks, while the latter include soft computing in data analysis, image processing, decision-making, classification, series prediction, economics, control, and modeling. By providing readers with a timely, authoritative view on the field, and by discussing thought-provoking developments and challenges, the book will foster new research directions in the diverse areas of soft computing. .

  11. Cellular immunotherapy for soft tissue sarcomas

    Science.gov (United States)

    Finkelstein, Steven Eric; Fishman, Mayer; Conley, Anthony P.; Gabrilovich, Dmitry; Antonia, Scott; Chiappori, Alberto

    2015-01-01

    SUMMARY Soft tissue sarcomas are rare neoplasms, with approximately 9,000 new cases in the United States every year. Unfortunately, there is little progress in the treatment of metastatic soft tissue sarcomas in the past two decades beyond the standard approaches of surgery, chemotherapy, and radiation. Immunotherapy is a modality complementary to conventional therapy,. It is appealing because functional anti-tumor activity could affect both local-regional and systemic disease and act over a prolonged period of time. In this report, we review immunotherapeutic investigative strategies being developed, including several tumor vaccine, antigen vaccine, and dendritic cell vaccine strategies. PMID:22401634

  12. The Diagnostic and Prognostic Value of Hematological and Chemical Abnormalities in Soft Tissue Sarcoma: A Comparative Study in Patients with Benign and Malignant Soft Tissue Tumors.

    Science.gov (United States)

    Ariizumi, Takashi; Kawashima, Hiroyuki; Ogose, Akira; Sasaki, Taro; Hotta, Tetsuo; Hatano, Hiroshi; Morita, Tetsuro; Endo, Naoto

    2018-01-01

    The value of routine blood tests in malignant soft tissue tumors remains uncertain. To determine if these tests can be used for screening, the routine pretreatment blood test findings were retrospectively investigated in 359 patients with benign and malignant soft tissue tumors. Additionally, the prognostic potential of pretreatment blood abnormalities was evaluated in patients with soft tissue sarcomas. We compared clinical factors and blood tests findings between patients with benign and malignant soft tissue tumors using univariate and multivariate analysis. Subsequently, patients with malignant tumors were divided into two groups based on blood test reference values, and the prognostic significance of each parameter was evaluated. In the univariate analysis, age, tumor size, and tumor depth were significant clinical diagnostic factors. Significant increases in the granulocyte count, C-reactive protein (CRP) level, erythrocyte sedimentation rate (ESR), and γ-glutamyl transpeptidase (γ-GTP) levels were found in patients with malignant soft tissue tumors. Multiple logistic regression showed that tumor size and ESR were independent factors that predicted malignant soft tissue tumors. The Kaplan-Meier survival analysis revealed that granulocyte counts, γ-GTP levels, and CRP levels correlated significantly with overall survival. Thus, pretreatment routine blood tests are useful diagnostic and prognostic markers for diagnosing soft tissue sarcoma. © 2018 by the Association of Clinical Scientists, Inc.

  13. Unilateral hypertrophy of tensor fascia lata: a soft tissue tumor simulator

    Energy Technology Data Exchange (ETDEWEB)

    Ilaslan, H. [Department of Radiology, Mayo Clinic, 200 First Street, 55905, SW Rochester, MN (United States); Department of Radiology A21, Cleveland Clinic, Cleveland, OH (United States); Wenger, D.E. [Department of Radiology, Mayo Clinic, 200 First Street, 55905, SW Rochester, MN (United States); Shives, T.C. [Department of Orthopedic Surgery, Mayo Clinic, Rochester, MN (United States); Unni, K.K. [Department of Laboratory Medicine and Pathology, Mayo Clinic, Rochester, MN (United States)

    2003-11-01

    To describe the imaging findings in eight cases of unilateral tensor fascia lata (TFL) hypertrophy presenting as soft tissue masses. Imaging studies and medical charts of eight patients were reviewed retrospectively. The imaging studies included five radiographs, five computed tomography (CT) and six magnetic resonance imaging (MRI) examinations. The majority of patients (seven of eight) presented with a palpable proximal anterior thigh mass. One patient was asymptomatic and incidentally diagnosed. There were six females and two males. Ages ranged from 27 to 86 years old (mean 61). MRI and CT showed unilateral enlargement of the TFL muscle in all cases. TFL muscle hypertrophy is an uncommon clinical entity, which can simulate a soft tissue tumor. The characteristic appearance on CT or MRI allows a confident diagnosis of muscle hypertrophy to be made, avoiding unnecessary biopsy or surgical intervention. (orig.)

  14. Unilateral hypertrophy of tensor fascia lata: a soft tissue tumor simulator

    International Nuclear Information System (INIS)

    Ilaslan, H.; Wenger, D.E.; Shives, T.C.; Unni, K.K.

    2003-01-01

    To describe the imaging findings in eight cases of unilateral tensor fascia lata (TFL) hypertrophy presenting as soft tissue masses. Imaging studies and medical charts of eight patients were reviewed retrospectively. The imaging studies included five radiographs, five computed tomography (CT) and six magnetic resonance imaging (MRI) examinations. The majority of patients (seven of eight) presented with a palpable proximal anterior thigh mass. One patient was asymptomatic and incidentally diagnosed. There were six females and two males. Ages ranged from 27 to 86 years old (mean 61). MRI and CT showed unilateral enlargement of the TFL muscle in all cases. TFL muscle hypertrophy is an uncommon clinical entity, which can simulate a soft tissue tumor. The characteristic appearance on CT or MRI allows a confident diagnosis of muscle hypertrophy to be made, avoiding unnecessary biopsy or surgical intervention. (orig.)

  15. Comparison of computed tomography and radiography for detecting changes induced by malignant nasal neoplasia in dogs

    International Nuclear Information System (INIS)

    Park, R.D.; Beck, E.R.; LeCouteur, R.A.

    1992-01-01

    The ability of computed tomography and radiography to detect changes associated with nasal neoplasia was compared in dogs. Eighteen areas or anatomic structures were evaluated in 21 dogs for changes indicative of neoplasia. Computed tomography was superior (P < or = 0.05) to radiography for detecting changes in 14 of 18 areas. Radiography was not superior for detecting changes in any structure or area. Computed tomography reveals vital information not always detected radiographically to assist in providing a prognosis and in planning treatment for nasal neoplasms in dogs

  16. Imaging of benign and malignant soft tissue masses of the foot

    International Nuclear Information System (INIS)

    Waldt, Simone; Rummeny, Ernst J.; Woertler, Klaus; Rechl, Hans

    2003-01-01

    The foot is a relatively uncommon site of neoplastic and non-neoplastic soft tissue tumors. Although it contains a relatively small amount of somatic soft tissue elements, the foot is considerably rich in tendons, fasciae, retinaculae, and synovium. Corresponding to this distribution of soft tissue elements, some soft tissue lesions, such as giant cell tumor of tendon sheath, fibromatosis, and synovial sarcoma, are commonly seen in this location. Vascular tumors represent common soft tissue masses of the foot as well. Magnetic resonance imaging is the modality of choice in the assessment of soft tissue tumors. The presence of a suspected lesion can be confirmed and tumor margins can be defined accurately. In general, MRI does not provide histologic specificity, but considering some MR features may often help in correctly distinguishing benign from malignant lesions. In addition, characteristic features of the most common benign tumors (i.e., fibromatosis, cavernous hemangioma) and reactive processes of the foot (ganglion cyst, Morton's neuroma) often suggest a specific diagnosis. (orig.)

  17. Diode laser soft-tissue surgery: advancements aimed at consistent cutting, improved clinical outcomes.

    Science.gov (United States)

    Romanos, Georgios E

    2013-01-01

    Laser dentistry and soft-tissue surgery, in particular, have become widely adopted in recent years. Significant cost reductions for dental lasers and the increasing popularity of CADCAM, among other factors, have contributed to a substantial increase in the installed base of dental lasers, especially soft-tissue lasers. New development in soft-tissue surgery, based on the modern understanding of laser-tissue interactions and contact soft-tissue surgery mechanisms, will bring a higher quality and consistency level to laser soft-tissue surgery. Recently introduced diode-laser technology enables enhanced control of side effects that result from tissue overheating and may improve soft-tissue surgical outcomes.

  18. Deep soft tissue leiomyoma of the thigh

    International Nuclear Information System (INIS)

    Watson, G.M.T.; Saifuddin, A.; Sandison, A.

    1999-01-01

    A case of ossified leiomyoma of the deep soft tissues of the left thigh is presented. The radiographic appearance suggested a low-grade chondrosarcoma. MRI of the lesion showed signal characteristics similar to muscle on both T1- and T2-weighted spin echo sequences with linear areas of high signal intensity on T1-weighted images consistent with medullary fat in metaplastic bone. Histopathological examination of the resected specimen revealed a benign ossified soft tissue leiomyoma. (orig.)

  19. Review of soft tissue augmentation in the face

    Directory of Open Access Journals (Sweden)

    James Newman

    2009-08-01

    Full Text Available James NewmanFacial Plastic Surgery, Stanford University Medical Center, Palo Alto, CAFacial Plastic Surgery, Stanford University Medical Center, Palo Alto, CA, USAAbstract: A primary pillar of facial rejuvenation is the replacement of soft tissue atrophy via a variety of augmentation techniques. The techniques can be classified into three categories, skeletal onlay grafts, subcutaneous volumizers, and dermal fillers. While onlay grafts and subcutaneous volumizers have the most persistent results, the emergence of improved dermal fillers in the past 5 years has become increasingly popular. An accurate diagnosis of the level(s of soft tissue atrophy in the face needs to be made prior to selection of the category or combination of techniques. In the younger patient, the selection of a dermal filler or combination of fillers can be adequate for treatment. A comparison of the composition and characteristics of the available dermal fillers are discussed in detail to assist the clinician in understanding the actual mechanism of soft tissue augmentation. In the more advanced aging face, a combination of the three categories may be necessary to produce optimal results. Just as dermal fillers have become more differentiated to increase their longevity, the non-injectible long-lasting implants are becoming more developed to mimic accurate viscoelastic properties of the facial soft tissues. All three classes of augmentation techniques can provide patients with very satisfactory results as part of overall facial rejuvenation.Keywords: soft tissue, dermal fillers, facial implants, facial augmentation

  20. The reliability of a segmentation methodology for assessing intramuscular adipose tissue and other soft-tissue compartments of lower leg MRI images.

    Science.gov (United States)

    Karampatos, Sarah; Papaioannou, Alexandra; Beattie, Karen A; Maly, Monica R; Chan, Adrian; Adachi, Jonathan D; Pritchard, Janet M

    2016-04-01

    Determine the reliability of a magnetic resonance (MR) image segmentation protocol for quantifying intramuscular adipose tissue (IntraMAT), subcutaneous adipose tissue, total muscle and intermuscular adipose tissue (InterMAT) of the lower leg. Ten axial lower leg MRI slices were obtained from 21 postmenopausal women using a 1 Tesla peripheral MRI system. Images were analyzed using sliceOmatic™ software. The average cross-sectional areas of the tissues were computed for the ten slices. Intra-rater and inter-rater reliability were determined and expressed as the standard error of measurement (SEM) (absolute reliability) and intraclass coefficient (ICC) (relative reliability). Intra-rater and inter-rater reliability for IntraMAT were 0.991 (95% confidence interval [CI] 0.978-0.996, p soft tissue compartments, the ICCs were all >0.90 (p soft-tissue compartments of the lower leg. A standard operating procedure manual is provided to assist users, and SEM values can be used to estimate sample size and determine confidence in repeated measurements in future research.

  1. Resonant acoustic spectroscopy of soft tissues using embedded magnetomotive nanotransducers and optical coherence tomography

    International Nuclear Information System (INIS)

    Oldenburg, Amy L; Boppart, Stephen A

    2010-01-01

    We present a new method for performing dynamic elastography of soft tissue samples. By sensing nanoscale displacements with optical coherence tomography, a chirped, modulated force is applied to acquire the mechanical spectrum of a tissue sample within a few seconds. This modulated force is applied via magnetic nanoparticles, named 'nanotransducers', which are diffused into the tissue, and which contribute negligible inertia to the soft tissue mechanical system. Using this novel system, we observed that excised tissues exhibit mechanical resonance modes which are well described by a linear damped harmonic oscillator. Results are validated by using cylindrical tissue phantoms of agarose in which resonant frequencies (30-400 Hz) are consistent with longitudinal modes and the sample boundary conditions. We furthermore show that the Young's modulus can be computed from their measured resonance frequencies, analogous to resonant ultrasound spectroscopy for stiff material analysis. Using this new technique, named magnetomotive resonant acoustic spectroscopy (MRAS), we monitored the relative stiffening of an excised rat liver during a chemical fixation process.

  2. Functional Attachment of Soft Tissues to Bone: Development, Healing, and Tissue Engineering

    Science.gov (United States)

    Lu, Helen H.; Thomopoulos, Stavros

    2014-01-01

    Connective tissues such as tendons or ligaments attach to bone across a multitissue interface with spatial gradients in composition, structure, and mechanical properties. These gradients minimize stress concentrations and mediate load transfer between the soft and hard tissues. Given the high incidence of tendon and ligament injuries and the lack of integrative solutions for their repair, interface regeneration remains a significant clinical challenge. This review begins with a description of the developmental processes and the resultant structure-function relationships that translate into the functional grading necessary for stress transfer between soft tissue and bone. It then discusses the interface healing response, with a focus on the influence of mechanical loading and the role of cell-cell interactions. The review continues with a description of current efforts in interface tissue engineering, highlighting key strategies for the regeneration of the soft tissue–to-bone interface, and concludes with a summary of challenges and future directions. PMID:23642244

  3. Comparison of radiography, CT and MR imaging in detection of arthropathies in patients with hemophilia

    International Nuclear Information System (INIS)

    Yu Wei; Lin Qiang; Shang Wei; Zhu Haifeng; Meng Wei; Xu Ruiyi; Zhao Yongqiang; Shi Yongsheng

    2007-01-01

    Objective: To compare MR, CT, and radiography in the detection of arthropathies in patients with hemophilia. Methods: Forty-one symptomic joint images in the 14 patients with hemophilia, aged from 11 to 24 years, were used in this study. Each joint had the examinations of radiography, CT and MR within one day. The severity of each joint was staged using conventional radiographic classification. Severe HA patients with stage 5 were excluded from the study. Imaging findings of soft tissue swelling, osteoporosis, epiphyseal overgrowth, joint erosion, cyst, joint space narrowing, bone marrow, joint effusion, hemorrhage, synovial hypertrophy, widened intercondylar notch as well as anterior and posterior cruciate ligaments (only for knee joint) were used for the all imaging comparison. Results: The 41 symptomatic joints in 14 patients with hemophilia were classified by radiographic criteria into stage 0 (n=5), stage 1 (n=7), stage 2 (n=6), stage 3 (n=8) and stage 4 (n=15). Soft tissue swelling or joint effusion was observed in 33 joints by radiographs, in 34 joints by both CT and MR. Joint erosions were demonstrated in 34 joints by MR, in 33 joints by CT and 20 joints by radiographs. Joint cysts were shown in 21 joints by MR, in 18 joints by CT and 9 joints by radiographs. Significant differences in detection of erosion and cyst were found between radiography with either CT (P 0.05). MR showed improvement for detecting more foci of both erosion and cyst than CT and radiography, and also CT showed the improvement than radiography. Bone marrow edema 14 joints, hemorrhage in 34 joints and synovial hypertrophy in 27 joints were revealed on MR images. Conclusion: MRI is superior to CT and conventional radiography in detecting the abnormal changes and should be considered as the first choice among the imaging modalities in evaluating hemophilic arthropathies. (authors)

  4. Peripheral soft tissue ewing's sarcoma: a rare case report

    Directory of Open Access Journals (Sweden)

    Farzana Shegufta

    2013-07-01

    Full Text Available A 22 years male patient presented with gradual left forearm swelling for 6 months. X ray forearm revealed large soft tissue swelling with tiny calcification and mild scalloping at inner aspect of ulna and ultrasonogram (USG revealed soft tissue mass having calcification and necrotic areas within and spectral Doppler showed arterial type of blood flow with no augmentation. Later computerized tomography (CT scan showed soft tissue mass with necrotic area and calcification with no bony involvement. Magnetic resonance imaging (MRI with contrast revealed a large heterogeneously enhancing lobulated mixed intensity lesion in antero-medial compartment of the left forearm involving flexor group of muscles causing displacement of fat plane. MRI and subsequent histopathology of the lesion revealed it as a rare soft tissue Ewing’s sarcoma / primitive neuroectodermal tumor (PNET in extremity. Ibrahim Med. Coll. J. 2013; 7(2: 43-46

  5. Soft tissue sarcoma - diagnosis and treatment

    International Nuclear Information System (INIS)

    Ruka, W.; Rutkowski, P.; Krzakowski, M.

    2009-01-01

    Significant progress in the treatment of soft tissue sarcoma (STS), both primary tumor and local recurrences/metastatic disease, has been achieved in recent years. Surgery is essential modality, but the use of combined treatment (standard combination of surgery with adjuvant radiotherapy, chemotherapy in selected cases and perioperative rehabilitation) in highly-experienced centers increased possibility of cure and limitations of extent of local surgery. Current combined therapy together with the use of reconstructive methods allows for limb-sparing surgery in majority of soft tissue sarcoma patients (amputation in 10% of cases as compared to approximately 50% in the 1960 - 70s). The slow, but constant, increase of rate of soft tissue sarcoma patients with long-term survival has been observed. Contemporary 5-year overall survival rate in patients with extremity soft tissue sarcomas is 55 -78%. In case of diagnosis of metastatic disease the prognosis is still poor (survival of approximately 1 year). Good results of local therapy may be expected only after planned (e.g., after preoperative biopsy - tru - cut or incisional) radical surgical excision of primary tumor with pathologically negative margins (R0 resection). Following appropriate diagnostic check-up, adjuvant radiotherapy is necessary in the majority of patients treated with radical surgery need, as well as long-term rehabilitation and follow-up examinations in treating center are needed for at least 5 years. The progress is due to the introduction of targeted therapy acting on molecular or genetic cellular disturbances detected during studies on etiopathogenetic mechanisms of sarcoma subtypes. In view of rarity of sarcomas and necessity of multidisciplinary therapy, the crucial issue is that management of these tumors should be hold in experienced oncological sarcoma centers. (authors)

  6. Soft tissue sparganosis

    Energy Technology Data Exchange (ETDEWEB)

    Park, Ki Soon; Lee, Yul; Chung, Soo Young; Park, Choong Ki; Lee, Kwan Sup [Hallym University College of Medicine, Seoul (Korea, Republic of); Cho, In Hwan; Suh, Hyoung Sim [Daelin S. Mary' s Hospital, Seoul (Korea, Republic of)

    1993-11-15

    Sparganosis is a rare tissue-parasitic infestation caused by a plerocercoid tapeworm larva(sparganum), genus Spirometra. The most common clinical presentation of sparganosis is a palpable subcutaneous mass or masses. Fifteen simple radiographs and 10 ultrasosnograms of 17 patients with operatively verified subcutaneous sparganosis were retrospectively analyzed to find its radiologic characteristics for preoperative diagnosis of sparganosis. The location of the subcutaneous sparganosis were lower extremity, abdominal wall, breast, inguinal region and scrotum in order of frequency. The simple radiographs showed linear or elongated calcification with or without nodular elongated shaped soft tissue mass shadows in 8 patients, soft tissue mass shadow only in 2 patients and lateral abdominal wall thickening in 1 patient. But no specific findings was noted in 4 patients with small abdominal and inguinal masses. We could classify the subcutaneous sparganosis by ultrasound into 2 types: one is long band-like hypoechoic structures, corresponding to the subcutaneous tunnel-like tracks formed by migration of sparganum larva and the order is elongated or ovoid hyperechoic nodules, representing granulomas. Long band-like hypoechoic structures within or associated with mixed echoic granulomatous masses were noted in 6 patients and elongated or ovoid hypoechoic mass or masses were noted in 4 patients. In conclusion, sparganosis should be considered when these radiologic findings-irregular linear calcifications on simple radiograph and long band-like hypoechoic structures on ultrasonography, corresponding to the subcutaneous tunnel-like tracks formed by migration of sparganum larva are noted in the patients who have subcutaneous palpable mass or masses. And radiologic examination especially ultrasonography is very helpful to diagnose sparganosis.

  7. Deep soft tissue leiomyoma of the thigh

    Energy Technology Data Exchange (ETDEWEB)

    Watson, G.M.T.; Saifuddin, A. [Department of Radiology, The Royal National Orthopaedic Hospital Trust, Brockley Hill (United Kingdom); Sandison, A. [Department of Pathology, The Royal National Orthopaedic Hospital Trust, Stanmore, Middlesex (United Kingdom)

    1999-07-01

    A case of ossified leiomyoma of the deep soft tissues of the left thigh is presented. The radiographic appearance suggested a low-grade chondrosarcoma. MRI of the lesion showed signal characteristics similar to muscle on both T1- and T2-weighted spin echo sequences with linear areas of high signal intensity on T1-weighted images consistent with medullary fat in metaplastic bone. Histopathological examination of the resected specimen revealed a benign ossified soft tissue leiomyoma. (orig.) With 3 figs., 13 refs.

  8. Ultrasound of soft tissue masses of the hand

    Directory of Open Access Journals (Sweden)

    James Teh

    2012-12-01

    Full Text Available Most soft tissue mass lesions of the hand are benign. Ganglia are the commonest lesions encountered, followed by giant cell tumors of the tendon sheath. Malignant tumors are rare. Often a specific diagnosis can be achieved on imaging by considering the location and anatomical relations of the lesion within the hand or wrist, and assessing its morphology. Magnetic resonance imaging is an excellent modality for evaluating soft tissue tumors with its multiplanar capability and ability to characterize tissue. Ultrasound plays a complementary role to MRI. It is often the initial modality used for assessing masses as it is cheap and available, and allows reliable differentiation of cystic from solid lesions, along with a real time assessment of vascularity. This review describes the US appearances of the most frequently encountered soft tissue masses of the wrist and hand, correlating the findings with MRI where appropriate.

  9. Quality comparison of direct digital panoramic radiography and computed radiography panoramic

    Directory of Open Access Journals (Sweden)

    Dariush Goodarzipour

    2013-09-01

    Full Text Available BACKGROUND AND AIM: Digital panoramic X-ray images can be captured using photostimulable phosphors or solid-state detectors (i.e. charge-coupled devices and Flat-Panels. The first category is defined as computed radiography (CR or semi-direct radiography. The second technology that uses solid-state detectors is known as direct digital radiography (DDR. Both of these technologies have their own advantages and disadvantages. One of the most important fields in comparison of these systems is their resultant image quality. The purpose of this study was to compare the subjective image quality of DDR and CR digital panoramic system, and to assess the overall density and contrast of their images. METHODS: 200 patients were randomly allocated to two digital systems: Promax [central control digital (CCD] and XC [photostimulable phosphor plates (PSP]. Image quality was evaluated in six regions on a 3-point scale by three oral and maxillofacial radiologists independently. In addition, observers assessed overall density and contrast of each image on a 3-point scale. RESULTS: Using chi-square test, no statistically significant differences were found (P >0.05 in subjective image quality of anatomic structures between the two radiographic systems. But DDR system outperformed CR system in overall density and contrast of the image. P values for both overall density and contrast of the images was less than 0.001. CONCLUSIONS: The subjective image quality of CR and DDR panoramic systems in specified anatomic regions were found statistically comparable in this study. In overall density and contrast of the radiographs, DDR system proved better than CR system.

  10. Ultrasound elastography assessment of bone/soft tissue interface

    International Nuclear Information System (INIS)

    Parmar, Biren J; Yang, Xu; Chaudhry, Anuj; Shajudeen, Peer Shafeeq; Nair, Sanjay P; Righetti, Raffaella; Weiner, Bradley K; Tasciotti, Ennio; Krouskop, Thomas A

    2016-01-01

    We report on the use of elastographic imaging techniques to assess the bone/soft tissue interface, a region that has not been previously investigated but may provide important information about fracture and bone healing. The performance of axial strain elastograms and axial shear strain elastograms at the bone/soft tissue interface was studied ex vivo on intact and fractured canine and ovine tibias. Selected ex vivo results were corroborated on intact sheep tibias in vivo. The elastography results were statistically analyzed using elastographic image quality tools. The results of this study demonstrate distinct patterns in the distribution of the normalized local axial strains and axial shear strains at the bone/soft tissue interface with respect to the background soft tissue. They also show that the relative strength and distribution of the elastographic parameters change in the presence of a fracture and depend on the degree of misalignment between the fracture fragments. Thus, elastographic imaging modalities might be used in the future to obtain information regarding the integrity of bones and to assess the severity of fractures, alignment of bone fragments as well as to follow bone healing. (paper)

  11. Ultrasound elastography assessment of bone/soft tissue interface

    Science.gov (United States)

    Parmar, Biren J.; Yang, Xu; Chaudhry, Anuj; Shafeeq Shajudeen, Peer; Nair, Sanjay P.; Weiner, Bradley K.; Tasciotti, Ennio; Krouskop, Thomas A.; Righetti, Raffaella

    2016-01-01

    We report on the use of elastographic imaging techniques to assess the bone/soft tissue interface, a region that has not been previously investigated but may provide important information about fracture and bone healing. The performance of axial strain elastograms and axial shear strain elastograms at the bone/soft tissue interface was studied ex vivo on intact and fractured canine and ovine tibias. Selected ex vivo results were corroborated on intact sheep tibias in vivo. The elastography results were statistically analyzed using elastographic image quality tools. The results of this study demonstrate distinct patterns in the distribution of the normalized local axial strains and axial shear strains at the bone/soft tissue interface with respect to the background soft tissue. They also show that the relative strength and distribution of the elastographic parameters change in the presence of a fracture and depend on the degree of misalignment between the fracture fragments. Thus, elastographic imaging modalities might be used in the future to obtain information regarding the integrity of bones and to assess the severity of fractures, alignment of bone fragments as well as to follow bone healing.

  12. Imaging of soft tissue sarcomas

    International Nuclear Information System (INIS)

    Vanel, D.; Le Treut, A.

    1988-01-01

    Modern imaging of soft tissue sarcomas now includes ultrasounds, CT and MRI. These new techniques allow a better evaluation of initial local extension, of the response to treatment and are able to detect local recurrences early [fr

  13. Breathing life into dinosaurs: tackling challenges of soft-tissue restoration and nasal airflow in extinct species.

    Science.gov (United States)

    Bourke, Jason M; Porter, W M Ruger; Ridgely, Ryan C; Lyson, Tyler R; Schachner, Emma R; Bell, Phil R; Witmer, Lawrence M

    2014-11-01

    The nasal region plays a key role in sensory, thermal, and respiratory physiology, but exploring its evolution is hampered by a lack of preservation of soft-tissue structures in extinct vertebrates. As a test case, we investigated members of the "bony-headed" ornithischian dinosaur clade Pachycephalosauridae (particularly Stegoceras validum) because of their small body size (which mitigated allometric concerns) and their tendency to preserve nasal soft tissues within their hypermineralized skulls. Hypermineralization directly preserved portions of the olfactory turbinates along with an internal nasal ridge that we regard as potentially an osteological correlate for respiratory conchae. Fossil specimens were CT-scanned, and nasal cavities were segmented and restored. Soft-tissue reconstruction of the nasal capsule was functionally tested in a virtual environment using computational fluid dynamics by running air through multiple models differing in nasal soft-tissue conformation: a bony-bounded model (i.e., skull without soft tissue) and then models with soft tissues added, such as a paranasal septum, a scrolled concha, a branched concha, and a model combining the paranasal septum with a concha. Deviations in fluid flow in comparison to a phylogenetically constrained sample of extant diapsids were used as indicators of missing soft tissue. Models that restored aspects of airflow found in extant diapsids, such as appreciable airflow in the olfactory chamber, were judged as more likely. The model with a branched concha produced airflow patterns closest to those of extant diapsids. These results from both paleontological observation and airflow modeling indicate that S. validum and other pachycephalosaurids could have had both olfactory and respiratory conchae. Although respiratory conchae have been linked to endothermy, such conclusions require caution in that our re-evaluation of the reptilian nasal apparatus indicates that respiratory conchae may be more widespread

  14. Aspergillus: a rare primary organism in soft-tissue infections.

    Science.gov (United States)

    Johnson, M A; Lyle, G; Hanly, M; Yeh, K A

    1998-02-01

    Nonclostridial necrotizing soft-tissue infections are usually polymicrobial, with greater than 90 per cent involving beta-hemolytic streptococci or coagulase-positive staphylococci. The remaining 10 per cent are usually due to Gram-negative enteric pathogens. We describe the case of a 46-year-old woman with bilateral lower extremity fungal soft tissue infections. She underwent multiple surgical debridements of extensive gangrenous necrosis of the skin and subcutaneous fat associated with severe acute arteritis. Histopathological examination revealed Aspergillus niger as the sole initial pathogen. Despite aggressive surgical debridement, allografts, and intravenous amphotericin B, her condition clinically deteriorated and she ultimately died of overwhelming infection. Treatment for soft-tissue infections include surgical debridement and intravenous antibiotics. More specifically, Aspergillus can be treated with intravenous amphotericin B, 5-fluorocytosine, and rifampin. Despite these treatment modalities, necrotizing fascitis is associated with a 60 per cent mortality rate. Primary fungal pathogens should be included in the differential diagnosis of soft-tissue infections.

  15. THE EFFECTS OF MAXILLARY EXPANSION ON THE SOFT TISSUE FACIAL PROFILE

    Directory of Open Access Journals (Sweden)

    Işıl ARAS

    2017-10-01

    Full Text Available Purpose: The aims of this retrospective study were to evaluate the possible changes in soft tissue facial profile induced by orthopedic rapid maxillary expansion (RME and surgically assisted rapid maxillary expansion (SARME, and to correlate them with the underlying hard tissue alterations. Materials and Methods: 16 patients who received bone borne SARME and 25 patients who were subjected to RME using metal cast splint hyrax appliance were analyzed retrospectively. This research was conducted on lateral cephalometric radiographs taken on 2 occasions: before expansion (T1 and at the beginning of any further orthodontic treatment (T2. Investigated lateral cephalometric parameters consisted of Holdaway soft tissue measurements with some supplementary soft tissue, skeletal and dental assessments. Results: The acquisition of T2 cephalograms which conforms to the initiation of further orthodontic treatment corresponded to 83.25±3.51 days for SARME and 85.68±4.37 days for RME after the expansion was completed. The only significant change in soft tissue profile of the SARME group was a decrease in upper lip thickness (p<0.05, whereas in the RME group, decrease in soft tissue facial profile angle and increase in H angle were found to be statistically significant (p<0.05 for each. For the RME group, the changes in soft tissue facial profile angle and H angle correlated only with the changes in SNB angle (p<0.05. Conclusion: While bone-borne SARME did not seem to possess the potential to alter soft tissue profile, tooth-borne RME caused a more convex soft tissue profile related to a reduction in SNB.

  16. Childhood Soft Tissue Sarcoma Treatment (PDQ®)—Health Professional Version

    Science.gov (United States)

    Pediatric soft tissue sarcomas are a heterogenous group of malignant tumors that originate from primitive mesenchymal tissue and account for 7% of all childhood tumors. Get detailed information about clinical presentation, diagnosis, prognosis, and treatment of newly diagnosed and recurrent soft tissue sarcoma in this summary for clinicians.

  17. A biphasic model for bleeding in soft tissue

    Science.gov (United States)

    Chang, Yi-Jui; Chong, Kwitae; Eldredge, Jeff D.; Teran, Joseph; Benharash, Peyman; Dutson, Erik

    2017-11-01

    The modeling of blood passing through soft tissues in the body is important for medical applications. The current study aims to capture the effect of tissue swelling and the transport of blood under bleeding or hemorrhaging conditions. The soft tissue is considered as a non-static poro-hyperelastic material with liquid-filled voids. A biphasic formulation effectively, a generalization of Darcy's law-is utilized, treating the phases as occupying fractions of the same volume. The interaction between phases is captured through a Stokes-like friction force on their relative velocities and a pressure that penalizes deviations from volume fractions summing to unity. The soft tissue is modeled as a hyperelastic material with a typical J-shaped stress-strain curve, while blood is considered as a Newtonian fluid. The method of Smoothed Particle Hydrodynamics is used to discretize the conservation equations based on the ease of treating free surfaces in the liquid. Simulations of swelling under acute hemorrhage and of draining under gravity and compression will be demonstrated. Ongoing progress in modeling of organ tissues under injuries and surgical conditions will be discussed.

  18. Soft-tissue reactions following irradiation of primary brain and pituitary tumors

    International Nuclear Information System (INIS)

    Baglan, R.J.; Marks, J.E.

    1981-01-01

    One hundred and ninety-nine patients who received radiation therapy for a primary brain or pituitary tumor were studied for radiation-induced soft-tissue reactions of the cranium, scalp, ears and jaw. The frequency of these reactions was studied as a function of: the radiation dose 5 mm below the skin surface, dose distribution, field size and fraction size. Forty percent of patients had complete and permanent epilation, while 21% had some other soft-tissue complication, including: scalp swelling-6%, external otitis-6%, otitis media-5%, ear swelling-4%, etc. The frequency of soft-tissue reactions correlates directly with the radiation dose at 5 mm below the skin surface. Patients treated with small portals ( 2 ) had few soft-tissue reactions. The dose to superficial tissues, and hence the frequency of soft-tissue reactions can be reduced by: (1) using high-energy megavoltage beams; (2) using equal loading of beams; and (3) possibly avoiding the use of electron beams

  19. Practical applications of soft computing in engineering

    CERN Document Server

    2001-01-01

    Soft computing has been presented not only with the theoretical developments but also with a large variety of realistic applications to consumer products and industrial systems. Application of soft computing has provided the opportunity to integrate human-like vagueness and real-life uncertainty into an otherwise hard computer program. This book highlights some of the recent developments in practical applications of soft computing in engineering problems. All the chapters have been sophisticatedly designed and revised by international experts to achieve wide but in-depth coverage. Contents: Au

  20. MR imaging of soft tissue tumors and tumor-like lesions

    Energy Technology Data Exchange (ETDEWEB)

    Laor, Tal [Department of Radiology, Cincinnati Children' s Hospital Medical Center, 3333 Burnet Avenue, 45229, Cincinnati, OH (United States)

    2004-01-01

    The evaluation of a soft tissue mass in a child should proceed with a differential diagnosis in mind, based on the clinical history, age of the child, and location of the abnormality. Small, superficial masses can be initially evaluated with sonography. More extensive or deep lesions usually require cross-sectional imaging. With the exception of myositis ossificans, magnetic resonance (MR) imaging has largely replaced the use of computed tomography. MR imaging is used to delineate the extent of a lesion, to evaluate response to therapy, and to monitor postoperative complications. There is great overlap in the MR imaging characteristics of benign and malignant lesions, making tissue sampling imperative for diagnosis. (orig.)

  1. Ultrasonographic findings of benign soft tissue tumors

    International Nuclear Information System (INIS)

    Kim, Ki Sung; Oh, Dong Heon; Jung, Tae Gun; Kim, Yong Kil; Kwon, Jung Hyeok

    1994-01-01

    To clarify the characteristic sonographic features of benign soft tissue tumors and to evaluate the usefulness of sonographic imaging. We retrospectively reviewed ultrasonographic images of 70 cases in 68 patients with histologically proved benign soft tissue tumors. The tumors include 33 lipomas, 11 hemangiomas, 11 lymphangiomas, 7 neurilemmomas, 4 epidermoid cysts, 2 fibromas, 1 mesenchymoma, and 1 myxoma. The sonographic appearances of the lesions were mainly solid in 53 cases(33 lipomas, 8 hemangiomas, 2 lymphangiomas, 7 neurilemmomas, 2 fibromas and 1 mesenchymoma), mainly cystic in 14 cases(1 hemangioma, 8 lymphangiomas, 4 epidermoid cysts, and 1 myxomal), and mixed in 3 cases(2 hemangiomas and 1 lymphangioma). Although an accurate histologic prediction could not be made in most cases, certain patterns appeared to be characteristic of specific tumor types. 26 cases(78%) of lipoma were seen as lentiform, iso- or hyperechoic, solid mass. Hemangioma had variable appearance and characteristic calcifications were seen in 3 cases. Unicameral or multiseptated cystic mass with variable thickness of echogenic septa and solid portion was the characteristic finding of lymhangioma. Neurilemmoma showed lobulated, oval to round , relatively hypoechoic mass or with without internal cystic portion. Sonographic evaluation of benign soft tissue tumors is useful in demonstrating the location, size, extent, and internal characteristic of the mass. A relatively confident diagnosis can made when the characteristic features of the benign soft tissue tumor are present on sonographic imaging

  2. Ultrasonographic findings of benign soft tissue tumors

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ki Sung; Oh, Dong Heon; Jung, Tae Gun; Kim, Yong Kil; Kwon, Jung Hyeok [Dongkang Genernal Hospital, Ulsan (Korea, Republic of)

    1994-05-15

    To clarify the characteristic sonographic features of benign soft tissue tumors and to evaluate the usefulness of sonographic imaging. We retrospectively reviewed ultrasonographic images of 70 cases in 68 patients with histologically proved benign soft tissue tumors. The tumors include 33 lipomas, 11 hemangiomas, 11 lymphangiomas, 7 neurilemmomas, 4 epidermoid cysts, 2 fibromas, 1 mesenchymoma, and 1 myxoma. The sonographic appearances of the lesions were mainly solid in 53 cases(33 lipomas, 8 hemangiomas, 2 lymphangiomas, 7 neurilemmomas, 2 fibromas and 1 mesenchymoma), mainly cystic in 14 cases(1 hemangioma, 8 lymphangiomas, 4 epidermoid cysts, and 1 myxomal), and mixed in 3 cases(2 hemangiomas and 1 lymphangioma). Although an accurate histologic prediction could not be made in most cases, certain patterns appeared to be characteristic of specific tumor types. 26 cases(78%) of lipoma were seen as lentiform, iso- or hyperechoic, solid mass. Hemangioma had variable appearance and characteristic calcifications were seen in 3 cases. Unicameral or multiseptated cystic mass with variable thickness of echogenic septa and solid portion was the characteristic finding of lymhangioma. Neurilemmoma showed lobulated, oval to round , relatively hypoechoic mass or with without internal cystic portion. Sonographic evaluation of benign soft tissue tumors is useful in demonstrating the location, size, extent, and internal characteristic of the mass. A relatively confident diagnosis can made when the characteristic features of the benign soft tissue tumor are present on sonographic imaging.

  3. Soft tissue sarcoma of the extremity.

    LENUS (Irish Health Repository)

    Cooper, T M

    2012-02-03

    A retrospective review of 33 cases of soft tissue sarcoma of the extremity presenting over a 10 year period was undertaken. The history, patterns of referral, diagnostic investigations, procedures undertaken and outcomes were studied. We found there was a frequent delay in diagnosis and sometimes misinterpretation of biopsy specimens. Patients were seen by a variety of specialists from disciplines such as general surgery, plastic surgery, orthopaedic surgery and rheumatology. Considerable progress has been made in the treatment of soft tissue sarcomas, often allowing local control of the tumour without amputation. We believe there should be early referral of patients having these tumours to a centre where a combined multidisciplinary approach can be undertaken.

  4. Soft-tissue amyloidoma with associated plasmacytoma

    Directory of Open Access Journals (Sweden)

    Bibhas Saha Dalal

    2016-01-01

    Full Text Available Soft tissue amyloidoma with features similar to plasmacytoma, in absence of systemic amyloidosis, is an extremely rare finding. We hereby report the case of a 77 year old man who presented with a painless, nodular swelling on chest wall, diagnosed as soft tissue amyloidoma with plasma cell infiltration. Congo red staining was done to prove the presence of amyloid which showed characteristic "apple-green" birefringence on polarized microscopy. The plasma cells were monoclonal in origin as demonstrated by serum protein and immunofixation electrophoresis. To the best of our knowledge, this is the second such reported case. However close follow up is required, as this patient may develop multiple myeloma in future.

  5. Managing the Difficult Soft Tissue Envelope in Facial and Rhinoplasty Surgery.

    Science.gov (United States)

    Kosins, Aaron M; Obagi, Zein E

    2017-02-01

    The nasal soft tissue envelope affects the final rhinoplasty result, and can limit the expected improvement. Currently, no dependable and objective test exists to measure the thickness of the nasal skin and underlying soft tissue. This paper presents a simple, yet reliable method to determine the thickness of the soft tissue envelope. An algorithm is presented for treatment of the dermis and/or soft tissue apart from surgery of the underlying osseocartilaginous structures. Seventy-five patients presenting for primary rhinoplasty underwent visual and ultrasound assessment of their nasal soft tissue envelope. At preoperative evaluation, the Obagi "skin pinch test" was used to assess the thickness of the nasolabial fold and whether or not the skin was oily. Patients were classified based on the pinch thickness. At time of surgery prior to injection of local anesthesia, ultrasonic assessment was done at the nasolabial fold, keystone junction, supratip, and tip to measure the thickness of the nasal dermis and underlying soft tissue. Patients determined to have thin, normal, and thick skin by the "skin pinch test" were found to have a nasolabial fold dermal thickness with an average of 0.7 mm (0.4-1.2 mm), 1.1 mm (0.8-1.8 mm), and 1.4 mm (0.7-2.0 mm). Patients determined to have thin, normal, and thick skin were found to have a dermal thickness at the keystone junction with an average of 0.3 mm (0.2-0.4 mm), 0.5 mm (0.3-1.1 mm), and 0.9 mm (0.6-1.2 mm), respectively. This difference in thickness also translated to the supratip and tip areas measured. However, all areas were also affected by the oiliness of the skin. Soft tissue thickness (SMAS and muscle) underlying the dermis was variable. Patients of non-Caucasian background were more likely to have a thicker soft tissue layer. The "skin pinch test" is an easy and reliable way for the surgeon to evaluate the thickness of the nasal soft tissue envelope. The rhinoplasty surgeon can make decisions pre- and postoperatively

  6. Bones - joints - soft tissues II. 7. rev. ed. Knochen - Gelenke - Weichteile II

    Energy Technology Data Exchange (ETDEWEB)

    Dihlmann, W. (Roentgeninstitut, Allgemeines Krankenhaus Barmbek, Hamburg (Germany)); Frommhold, W. (Radiologische Klinik, Tuebingen Univ. (Germany)) (eds.)

    1991-01-01

    With the publication of the 2nd part to Volume VI, 'Bones - joints - soft tissues', the 7th edition of 'Diagnostic radiology in the hospital and medical practice' is complete. The advances made particularly during the past decade in the field of diagnostic radiology have made it neccesary for all the individual sections to be completely revised. Recently developed methods of imaging like sonography, computed tomography and magnetic resonance tomography are increasingly used as a replacement for or, at least, an adjunct to conventional X-ray procedures. Owing to the development and continuous refinement of related methods of intervention the gap between mere diagnostic applications and therapeutic uses of radiology could eventually be closed. The issues mainly discussed in this volume are bone fractures and healing, bone transplantation, osteopathy and osteoarthropathy, fibrous dyplasia or Albright's disease, Pagetoid osteitis, genetically transmitted constitutional disorders of the skeleton and soft tissue changes. While in the key sections on bone fractures and healing, osteopathy and osteoarthropathy as well as constitutional genetic disorders X-ray techniques are still described as the prevailing method of diagnosis, diseases of soft tissues now are much more commonly diagnosed using magnetic resonance imaging. (orig./MG) With 2248 figs., 59 tabs.

  7. Trochanteric Soft Tissue Thickness and Hip Fracture in Older Men

    Science.gov (United States)

    Nielson, Carrie M.; Bouxsein, Mary L.; Freitas, Sinara S.; Ensrud, Kristine E.; Orwoll, Eric S.

    2009-01-01

    Background: Greater thickness of the tissue extending laterally from the greater trochanter has been associated with a lower risk of hip fracture in women. The effect of trochanteric soft tissue thickness on the risk of incident hip fracture has not been evaluated in men. Methods: We measured trochanteric soft tissue thickness by dual-energy x-ray absorptiometry for all incident hip fracture cases (n = 70) and 222 randomly selected noncases in older men (≥65 yr) enrolled in the Osteoporotic Fractures in Men (MrOS) Study. Differences in tissue thickness between cases and controls were examined. Changes in fall force and factor-of-risk (the ratio of force from a sideways fall to femoral bone strength) associated with tissue thickness were determined. The relative risk for incident hip fracture per sd decrease in tissue thickness was calculated. Results: Mean trochanteric soft tissue thickness did not differ significantly between cases and noncases (29.1 ± 11.9 vs 31.0 ± 11.5 mm; P = 0.2). Although increased tissue thickness reduced both the estimates of fall force and the factor-of-risk, tissue thickness was not associated with the risk of hip fracture (age- and bone mineral density-adjusted relative risk per sd decrease in tissue thickness = 0.90; 95% confidence interval, 0.70–1.16). Conclusions: In this study of elderly community-dwelling men, we found no significant association between trochanteric soft tissue thickness and incident hip fracture. Trochanteric soft tissue thickness in these men was less than previously reported in older women and may explain the difference between these results and those reported in women. PMID:19017753

  8. Soft-tissue facial characteristics of attractive Chinese men compared to normal men.

    Science.gov (United States)

    Wu, Feng; Li, Junfang; He, Hong; Huang, Na; Tang, Youchao; Wang, Yuanqing

    2015-01-01

    To compare the facial characteristics of attractive Chinese men with those of reference men. The three-dimensional coordinates of 50 facial landmarks were collected in 40 healthy reference men and in 40 "attractive" men, soft tissue facial angles, distances, areas, and volumes were computed and compared using analysis of variance. When compared with reference men, attractive men shared several similar facial characteristics: relatively large forehead, reduced mandible, and rounded face. They had a more acute soft tissue profile, an increased upper facial width and middle facial depth, larger mouth, and more voluminous lips than reference men. Attractive men had several facial characteristics suggesting babyness. Nonetheless, each group of men was characterized by a different development of these features. Esthetic reference values can be a useful tool for clinicians, but should always consider the characteristics of individual faces.

  9. Soft tissue wound healing around teeth and dental implants.

    Science.gov (United States)

    Sculean, Anton; Gruber, Reinhard; Bosshardt, Dieter D

    2014-04-01

    To provide an overview on the biology and soft tissue wound healing around teeth and dental implants. This narrative review focuses on cell biology and histology of soft tissue wounds around natural teeth and dental implants. The available data indicate that: (a) Oral wounds follow a similar pattern. (b) The tissue specificities of the gingival, alveolar and palatal mucosa appear to be innately and not necessarily functionally determined. (c) The granulation tissue originating from the periodontal ligament or from connective tissue originally covered by keratinized epithelium has the potential to induce keratinization. However, it also appears that deep palatal connective tissue may not have the same potential to induce keratinization as the palatal connective tissue originating from an immediately subepithelial area. (d) Epithelial healing following non-surgical and surgical periodontal therapy appears to be completed after a period of 7–14 days. Structural integrity of a maturing wound between a denuded root surface and a soft tissue flap is achieved at approximately 14-days post-surgery. (e) The formation of the biological width and maturation of the barrier function around transmucosal implants requires 6–8 weeks of healing. (f) The established peri-implant soft connective tissue resembles a scar tissue in composition, fibre orientation, and vasculature. (g) The peri-implant junctional epithelium may reach a greater final length under certain conditions such as implants placed into fresh extraction sockets versus conventional implant procedures in healed sites. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  10. Soft tissue twisting injuries of the knee

    International Nuclear Information System (INIS)

    Magee, T.; Shapiro, M.

    2001-01-01

    Twisting injuries occur as a result of differential motion of different tissue types in injuries with some rotational force. These injuries are well described in brain injuries but, to our knowledge, have not been described in the musculoskeletal literature. We correlated the clinical examination and MR findings of 20 patients with twisting injuries of the soft tissues around the knee. Design and patients: We prospectively followed the clinical courses of 20 patients with knee injuries who had clinical histories and MR findings to suggest twisting injuries of the subcutaneous tissues. Patients with associated internal derangement of the knee (i.e., meniscal tears, ligamentous or bone injuries) were excluded from this study. MR findings to suggest twisting injuries included linear areas of abnormal dark signal on T1-weighted sequences and abnormal bright signal on T2-weighted or short tau inversion recovery (STIR) sequences and/or signal to suggest hemorrhage within the subcutaneous tissues. These MR criteria were adapted from those established for indirect musculotendinous junction injuries. Results: All 20 patients presented with considerable pain that suggested internal derangement on physical examination by the referring orthopedic surgeons. All presented with injuries associated with rotational force. The patients were placed on a course of protected weight-bearing of the affected extremity for 4 weeks. All patients had pain relief by clinical examination after this period of protected weight-bearing. Twisting injuries of the soft tissues can result in considerable pain that can be confused with internal derangement of the knee on physical examination. Soft tissue twisting injuries need to be recognized on MR examinations as they may be the cause of the patient's pain despite no MR evidence of internal derangement of the knee. The demonstration of soft tissue twisting injuries in a patient with severe knee pain but no documented internal derangement on MR

  11. Diode Laser Application in Soft Tissue Oral Surgery

    Science.gov (United States)

    Azma, Ehsan; Safavi, Nassimeh

    2013-01-01

    Introduction: Diode laser with wavelengths ranging from 810 to 980 nm in a continuous or pulsed mode was used as a possible instrument for soft tissue surgery in the oral cavity. Discussion: Diode laser is one of laser systems in which photons are produced by electric current with wavelengths of 810, 940 and 980nm. The application of diode laser in soft tissue oral surgery has been evaluated from a safety point of view, for facial pigmentation and vascular lesions and in oral surgery excision; for example frenectomy, epulis fissuratum and fibroma. The advantages of laser application are that it provides relatively bloodless surgical and post surgical courses with minimal swelling and scarring. We used diode laser for excisional biopsy of pyogenic granuloma and gingival pigmentation. Conclusion: The diode laser can be used as a modality for oral soft tissue surgery PMID:25606331

  12. Fuzzy logic, neural networks, and soft computing

    Science.gov (United States)

    Zadeh, Lofti A.

    1994-01-01

    The past few years have witnessed a rapid growth of interest in a cluster of modes of modeling and computation which may be described collectively as soft computing. The distinguishing characteristic of soft computing is that its primary aims are to achieve tractability, robustness, low cost, and high MIQ (machine intelligence quotient) through an exploitation of the tolerance for imprecision and uncertainty. Thus, in soft computing what is usually sought is an approximate solution to a precisely formulated problem or, more typically, an approximate solution to an imprecisely formulated problem. A simple case in point is the problem of parking a car. Generally, humans can park a car rather easily because the final position of the car is not specified exactly. If it were specified to within, say, a few millimeters and a fraction of a degree, it would take hours or days of maneuvering and precise measurements of distance and angular position to solve the problem. What this simple example points to is the fact that, in general, high precision carries a high cost. The challenge, then, is to exploit the tolerance for imprecision by devising methods of computation which lead to an acceptable solution at low cost. By its nature, soft computing is much closer to human reasoning than the traditional modes of computation. At this juncture, the major components of soft computing are fuzzy logic (FL), neural network theory (NN), and probabilistic reasoning techniques (PR), including genetic algorithms, chaos theory, and part of learning theory. Increasingly, these techniques are used in combination to achieve significant improvement in performance and adaptability. Among the important application areas for soft computing are control systems, expert systems, data compression techniques, image processing, and decision support systems. It may be argued that it is soft computing, rather than the traditional hard computing, that should be viewed as the foundation for artificial

  13. Idiopathic Soft Tissue Calcification in an Extremity: A Case Report

    Directory of Open Access Journals (Sweden)

    Dinesh Dhar

    2013-03-01

    Full Text Available We report a case of a-15-days-old infant presenting with firm palpable thickening of the left leg soft tissues along with induration. Radiographs of the leg revealed generalized calcification of soft tissues. No obvious underlying cause could be identified for tissue calcification and hence termed as Idiopathic calcinois cutis. There are reports of this condition in Pediatric and Dermatology literature, but very few reports in orthopedic literature. The aim of this report is to highlight the pathogenesis, course and review of literature of this relatively uncommon condition which can easily be mistaken by Orthopedic or General Surgeons for infective bony of soft tissue infection.

  14. SoftLab: A Soft-Computing Software for Experimental Research with Commercialization Aspects

    Science.gov (United States)

    Akbarzadeh-T, M.-R.; Shaikh, T. S.; Ren, J.; Hubbell, Rob; Kumbla, K. K.; Jamshidi, M

    1998-01-01

    SoftLab is a software environment for research and development in intelligent modeling/control using soft-computing paradigms such as fuzzy logic, neural networks, genetic algorithms, and genetic programs. SoftLab addresses the inadequacies of the existing soft-computing software by supporting comprehensive multidisciplinary functionalities from management tools to engineering systems. Furthermore, the built-in features help the user process/analyze information more efficiently by a friendly yet powerful interface, and will allow the user to specify user-specific processing modules, hence adding to the standard configuration of the software environment.

  15. Current Molecular Targeted Therapies for Bone and Soft Tissue Sarcomas

    Directory of Open Access Journals (Sweden)

    Kenji Nakano

    2018-03-01

    Full Text Available Systemic treatment options for bone and soft tissue sarcomas remained unchanged until the 2000s. These cancers presented challenges in new drug development partly because of their rarity and heterogeneity. Many new molecular targeting drugs have been tried in the 2010s, and some were approved for bone and soft tissue sarcoma. As one of the first molecular targeted drugs approved for solid malignant tumors, imatinib’s approval as a treatment for gastrointestinal stromal tumors (GISTs has been a great achievement. Following imatinib, other tyrosine kinase inhibitors (TKIs have been approved for GISTs such as sunitinib and regorafenib, and pazopanib was approved for non-GIST soft tissue sarcomas. Olaratumab, the monoclonal antibody that targets platelet-derived growth factor receptor (PDGFR-α, was shown to extend the overall survival of soft tissue sarcoma patients and was approved in 2016 in the U.S. as a breakthrough therapy. For bone tumors, new drugs are limited to denosumab, a receptor activator of nuclear factor κB ligand (RANKL inhibitor, for treating giant cell tumors of bone. In this review, we explain and summarize the current molecular targeting therapies approved and in development for bone and soft tissue sarcomas.

  16. Roentgenographic study on maxillofacial soft tissue in the mixed dentition

    International Nuclear Information System (INIS)

    Lee, Jai Hei; Ahn, Hyung Kyu

    1977-01-01

    The purpose of this study was to obtain the cephalometric maxillofacial soft tissue measurements and to define the differences that exist between male and female on the soft tissue profile who had normal occlusion in mixed dentitions. For the object of this study, cephalometric radiographs were obtained from the centric occlusion with the relaxed lip position. Copper filter was designed to obtain both hard and soft tissue structure on the same film. The subjects consist of 100 male and 100 female from 8 to 12.4 years with the normal occlusion and acceptable profiles. The author measured facial depth, vertical height from the cephalometric soft tissue profiles in the mixed dentitions. The significant test was performed to compare male with females. The following results were obtained from the study 1. In facial convexity, much more larger female than that of male. 2. Inclination of the lip posture was more larger in maxilla (male) and in female more larger in the mandible. 3. The thickness of soft tissue was thicker in male, the height of nose was more prominent in female. 4. There were no significant differences in both sexes.

  17. Soft Tissue Extramedullary Plasmacytoma

    Directory of Open Access Journals (Sweden)

    Fernando Ruiz Santiago

    2010-01-01

    Full Text Available We present the uncommon case of a subcutaneous fascia-based extramedullary plasmacytoma in the leg, which was confirmed by the pathology report and followed up until its remission. We report the differential diagnosis with other more common soft tissue masses. Imaging findings are nonspecific but are important to determine the tumour extension and to plan the biopsy.

  18. Computed simulation of radiographies of pipes - validation of techniques for wall thickness measurements

    International Nuclear Information System (INIS)

    Bellon, C.; Tillack, G.R.; Nockemann, C.; Wenzel, L.

    1995-01-01

    A macroscopic model of radiographic NDE methods and applications is given. A computer-aided approach for determination of wall thickness from radiographs is presented, guaranteeing high accuracy and reproducibility of wall thickness determination by means of projection radiography. The algorithm was applied to computed simulations of radiographies. The simulation thus offers an effective means for testing such automated wall thickness determination as a function of imaging conditions, pipe geometries, coatings, and media tracking, and likewise is a tool for validation and optimization of the method. (orig.) [de

  19. Magnetic resonance imaging of pediatric soft-tissue vascular anomalies

    International Nuclear Information System (INIS)

    Navarro, Oscar M.

    2016-01-01

    Magnetic resonance (MR) imaging can be used in the management of pediatric soft-tissue vascular anomalies for diagnosing and assessing extent of lesions and for evaluating response to therapy. MR imaging studies often involve a combination of T1- and T2-weighted images in addition to MR angiography and fat-suppressed post-contrast sequences. The MR imaging features of these vascular anomalies when combined with clinical findings can aid in diagnosis. In cases of complex vascular malformations and syndromes associated with vascular anomalies, MR imaging can be used to evaluate accompanying soft-tissue and bone anomalies. This article reviews the MR imaging protocols and appearances of the most common pediatric soft-tissue vascular anomalies. (orig.)

  20. Regional Analysis of Soft Tissue Thickness on Korean Buttocks and Application to Fasciocutaneous Flap Design

    Directory of Open Access Journals (Sweden)

    Do Yup Kim

    2014-03-01

    Full Text Available Background Various shapes and designs of the gluteal artery perforator flap have been used for treating sacral pressure sores and reconstructing breasts. To establish the ideal fasciocutaneous flap design for use in the gluteal area, the soft tissue thickness distribution was measured. Methods Twenty-one buttocks of adult Korean cadavers were analyzed through rectangular subfascial dissection. Each buttock was divided horizontally into 10 sections and vertically into 10 sections, and then, the thickness at the corners of the sections was measured. For the sake of comparison and statistical verification with living bodies, computed tomography (CT images of 120 buttocks of patients were randomly selected. Five horizontal sections and 4 vertical sections were made, and the thickness at each corner was recorded. Results According to the dissection and the CT images, the area with the thinnest soft tissues in the buttock was around the posterior superior iliac spine, close to the sacral area. The thickest area was the superolateral area of the buttock, which was 3.24 times and 2.15 times thicker than the thinnest area in the studies on cadaver anatomy and the CT images, respectively. Conclusions The thickness of the soft tissues in the buttocks differed by area. The superolateral area had the thickest soft tissues, and the superomedial area had the thinnest. This study includes information on the distribution of the thickness of the gluteal soft tissues of Koreans. The outcome of this study may contribute to the design of effective local flaps for pressure sore reconstruction and free flaps for breast reconstruction.

  1. Radiation-induced soft-tissue and bone sarcoma

    International Nuclear Information System (INIS)

    Kim, J.H.; Chu, F.C.; Woodard, H.Q.; Melamed, R.; Huvos, A.; Cantin, J.

    1978-01-01

    From the records of Memorial Hospital of the past 50 years, 47 cases with an established diagnosis of radiation-induced sarcoma were identified and divided into two groups: the first included 20 cases of soft-tissue sarcoma arising from irradiated tissues, and the second comprised 27 cases of bone sarcoma arising from normal bones in the irradiated field. Medians for the latent periods from irradiation to diagnosis of bone and soft-tissue sarcoma were 11 and 12, years, respectively. In bone sarcomas, the latent period was longer after larger radiation doses and children appeared to be more susceptible to cancer induction than adults. Criteria for establishing the diagnosis of radiation-induced sarcoma and the magnitude of the risk of bone sarcoma are discussed

  2. Soft tissue augmentation 2006: filler fantasy.

    Science.gov (United States)

    Klein, Arnold William

    2006-01-01

    As an increasing number of patients seek esthetic improvement through minimally invasive procedures, interest in soft tissue augmentation and filling agents is at an all-time high. One reason for this interest is the availability of botulinum toxin type A, which works superbly in the upper face. The rejuvenation of the upper face has created much interest in injectable filling agents and implant techniques that work equally well in the restoration of the lower face. One of the central tenets of soft tissue augmentation is the concept of the three-dimensional face. The youthful face has a soft, full appearance, as opposed to the flat, pulled, two-dimensional look often achieved by more traditional surgical approaches. Injectable filling agents can augment and even at times, replace pulling. Additionally, with the lip as the focal center of the lower face, subtle lip enhancement is here to stay, and is in fact, the number one indication for injectable fillers. Moreover, minimally invasive soft tissue augmentation offers cosmetic enhancement without the cost and recovery time associated with more invasive procedures. As more and more physicians take interest in minimally invasive surgery, courses in cosmetic surgery techniques are becoming increasingly popular at the medical meetings of many specialties. Today, physicians have a much larger armamentarium of techniques and materials with which to improve facial contours, ameliorate wrinkles, and provide esthetic rejuvenation to the face. For a substance or device to be amenable for soft tissue augmentation in the medical community, it must meet certain criteria. It must have both a high "use" potential, producing cosmetically pleasing results with a minimum undesirable reactions, and have a low abuse potential in that widespread or incorrect or indiscriminate use would not result in significant morbidity. It must be nonteratogenic, noncarcinogenic, and nonmigratory. In addition, the agent must provide predictable

  3. Mechanical verification of soft-tissue attachment on bioactive glasses and titanium implants.

    Science.gov (United States)

    Zhao, Desheng; Moritz, Niko; Vedel, Erik; Hupa, Leena; Aro, Hannu T

    2008-07-01

    Soft-tissue attachment is a desired feature of many clinical biomaterials. The aim of the current study was to design a suitable experimental method for tensile testing of implant incorporation with soft-tissues. Conical implants were made of three compositions of bioactive glass (SiO(2)-P(2)O(5)-B(2)O(3)-Na(2)O-K(2)O-CaO-MgO) or titanium fiber mesh (porosity 84.7%). The implants were surgically inserted into the dorsal subcutaneous soft-tissue or back muscles in the rat. Soft-tissue attachment was evaluated by pull-out testing using a custom-made jig 8 weeks after implantation. Titanium fiber mesh implants had developed a relatively high pull-out force in subcutaneous tissue (12.33+/-5.29 N, mean+/-SD) and also measurable attachment with muscle tissue (2.46+/-1.33 N). The bioactive glass implants failed to show mechanically relevant soft-tissue bonding. The experimental set-up of mechanical testing seems to be feasible for verification studies of soft-tissue attachment. The inexpensive small animal model is beneficial for large-scale in vivo screening of new biomaterials.

  4. Radiological protection procedures for industrial applications of computed radiography; Procedimentos de protecao radiologica em aplicacoes industriais da radiografia computadorizada

    Energy Technology Data Exchange (ETDEWEB)

    Aquino, Josilto Oliveira de

    2009-03-15

    Due to its very particular characteristics, industrial radiography is responsible for roughly half of the relevant accidents in nuclear industry, in developed as well as in developing countries, according to the International Atomic Energy Agency (IAEA). Thus, safety and radiological protection in industrial gamma radiography have been receiving especial treatment by regulatory authorities of most Member States. The main objective of the present work was to evaluate, from the radioprotection point of view, the main advantages of computed radiography (CR) for filmless industrial radiography. In order to accomplish this, both techniques, i.e. conventional and filmless computed radiography were evaluated and compared through practical studies. After the studies performed at the present work it was concluded that computed radiography significantly reduces the inherent doses, reflecting in smaller restricted areas and costs, with consequent improvement in radiological protection and safety. (author)

  5. Bone and soft tissue ischemia

    International Nuclear Information System (INIS)

    Berquist, T.H.; Brown, M.L.; Joyce, J.W.; Johnson, K.A.

    1989-01-01

    This paper discusses clinical features and imaging techniques for ischemic necrosis, a common problem in the foot, particularly in diabetics and patients with other vascular diseases. Necrosis of bone and soft tissues will be considered separately as the underlying etiology and imaging evaluation differ considerably

  6. Rehabilitation effect of exercise with soft tissue manipulation in ...

    African Journals Online (AJOL)

    Rehabilitation effect of exercise with soft tissue manipulation in patients with lumbar muscle strain. H Li, H Zhang, S Liu, Y Wang, D Gai, Q Lu, H Gan, Y Shi, W Qi. Abstract. Objective: To study the rehabilitation effect of exercise with soft tissue manipulation therapy for patients with lumbar muscle strain. Methods: Patients with ...

  7. Soft tissue and it’s affect on craniofacial growth and the dentition

    Directory of Open Access Journals (Sweden)

    Mansjur Nasir

    2016-06-01

    Full Text Available Soft tissue dysfunction, mouth breathing, tongue thrusting, incorrect swallowing and other myofunctional habits effect on malocclusion, poor facial development and relapse also Temporo Mandibular Joint (TMJ Disorder as well. How the dynamics of form and function affect the dentition, skeletal structures and the face. Soft tissues control dental position and should be considered in conjunction with any treatment. Treatment of soft tissue dysfunction will stable the result the orthodontic treatment. Diagnosis and treatment of soft tissue dysfunction is the responsibility of the General Dentist and Pedodontist and Orthodontist as well.

  8. Post-operative observation of ilio-apophyseal transplants on the basis of radiography, computed tomography, autoradiography and histological assessment

    International Nuclear Information System (INIS)

    Klatt, U.

    1987-01-01

    A study in 25 rabbits, in which the acetabular roof was reinforced by inserting a wedge-shaped autologous tissue fragment of the apophysis, led to the following conclusions: That complete healing and ossification of the implant took place within the observation period; that radiography, computed tomography, autoradiography and histology consistently provided evidence in confirmation of ossification; that a wedge-shaped fragment of apophyseal cartilage is a suitable material for plastic surgery in the acetabular roof. (TRV) [de

  9. Effect of bone-soft tissue friction on ultrasound axial shear strain elastography.

    Science.gov (United States)

    Tang, Songyuan; Chaudhry, Anuj; Kim, Namhee; Reddy, J N; Righetti, Raffaella

    2017-07-12

    Bone-soft tissue friction is an important factor affecting several musculoskeletal disorders, frictional syndromes and the ability of a bone fracture to heal. However, this parameter is difficult to determine using non-invasive imaging modalities, especially in clinical settings. Ultrasound axial shear strain elastography is a non-invasive imaging modality that has been used in the recent past to estimate the bonding between different tissue layers. As most elastography methods, axial shear strain elastography is primarily used in soft tissues. More recently, this technique has been proposed to assess the bone-soft tissue interface. In this paper, we investigate the effect of a variation in bone-soft tissue friction coefficient in the resulting axial shear strain elastograms. Finite element poroelastic models of bone specimens exhibiting different bone-soft tissue friction coefficients were created and mechanically analyzed. These models were then imported to an ultrasound elastography simulation module to assess the presence of axial shear strain patterns. In vitro experiments were performed to corroborate selected simulation results. The results of this study show that the normalized axial shear strain estimated at the bone-soft tissue interface is statistically correlated to the bone-soft tissue coefficient of friction. This information may prove useful to better interpret ultrasound elastography results obtained in bone-related applications and, possibly, monitor bone healing.

  10. Complicated acute appendicitis presenting as a rapidly progressive soft tissue infection of the abdominal wall: a case report.

    Science.gov (United States)

    Beerle, Corinne; Gelpke, Hans; Breitenstein, Stefan; Staerkle, Ralph F

    2016-12-01

    We report a case of a rare complication of acute appendicitis with perforation through the abdominal wall. The case points out that an intraabdominal origin should be considered in patients presenting with rapidly spreading soft tissue infections of the trunk. A 58-year-old European woman presented to our hospital with a 1-week history of severe abdominal pain accompanied by rapidly spreading erythema and emphysema of the lower abdomen. On admission, the patient was in septic shock with leukocytosis and elevation of C-reactive protein. Among other diagnoses, necrotizing fasciitis was suspected. Computed tomography showed a large soft tissue infection with air-fluid levels spreading through the lower abdominal wall. During the operation, we found a perforated appendicitis breaking through the fascia and causing a rapidly progressive soft tissue infection of the abdominal wall. Appendicitis was the origin of the soft tissue infection. The abdominal wall was only secondarily involved. Even though perforated appendicitis as an etiology of a rapidly progressive soft tissue infection of the abdominal wall is very rare, it should be considered in the differential diagnosis of abdominal wall cellulitis. The distinction between rapidly spreading subcutaneous infection with abscess formation and early onset of necrotizing fasciitis is often difficult and can be confirmed only by surgical intervention.

  11. Multiphase poroelastic finite element models for soft tissue structures

    International Nuclear Information System (INIS)

    Simon, B.R.

    1992-01-01

    During the last two decades, biological structures with soft tissue components have been modeled using poroelastic or mixture-based constitutive laws, i.e., the material is viewed as a deformable (porous) solid matrix that is saturated by mobile tissue fluid. These structures exhibit a highly nonlinear, history-dependent material behavior; undergo finite strains; and may swell or shrink when tissue ionic concentrations are altered. Give the geometric and material complexity of soft tissue structures and that they are subjected to complicated initial and boundary conditions, finite element models (FEMs) have been very useful for quantitative structural analyses. This paper surveys recent applications of poroelastic and mixture-based theories and the associated FEMs for the study of the biomechanics of soft tissues, and indicates future directions for research in this area. Equivalent finite-strain poroelastic and mixture continuum biomechanical models are presented. Special attention is given to the identification of material properties using a porohyperelastic constitutive law ans a total Lagrangian view for the formulation. The associated FEMs are then formulated to include this porohyperelastic material response and finite strains. Extensions of the theory are suggested in order to include inherent viscoelasticity, transport phenomena, and swelling in soft tissue structures. A number of biomechanical research areas are identified, and possible applications of the porohyperelastic and mixture-based FEMs are suggested. 62 refs., 11 figs., 3 tabs

  12. Differential diagnosis between benign and malignant soft tissue tumors utilizing ultrasound parameters.

    Science.gov (United States)

    Morii, Takeshi; Kishino, Tomonori; Shimamori, Naoko; Motohashi, Mitsue; Ohnishi, Hiroaki; Honya, Keita; Aoyagi, Takayuki; Tajima, Takashi; Ichimura, Shoichi

    2018-01-01

    Preoperative discrimination between benign and malignant soft tissue tumors is critical for the prevention of excess application of magnetic resonance imaging and biopsy as well as unplanned resection. Although ultrasound, including power Doppler imaging, is an easy, noninvasive, and cost-effective modality for screening soft tissue tumors, few studies have investigated reliable discrimination between benign and malignant soft tissue tumors. To establish a modality for discrimination between benign and malignant soft tissue tumors using ultrasound, we extracted the significant risk factors for malignancy based on ultrasound information from 40 malignant and 56 benign pathologically diagnosed soft tissue tumors and established a scoring system based on these risk factors. The maximum size, tumor margin, and vascularity evaluated using ultrasound were extracted as significant risk factors. Using the odds ratio from a multivariate regression model, a scoring system was established. Receiver operating characteristic analyses revealed a high area under the curve value (0.85), confirming the accuracy of the scoring system. Ultrasound is a useful modality for establishing the differential diagnosis between benign and malignant soft tissue tumors.

  13. A comparison of numerical methods used for finite element modelling of soft tissue deformation

    KAUST Repository

    Pathmanathan, P; Gavaghan, D; Whiteley, J

    2009-01-01

    Soft tissue deformation is often modelled using incompressible non-linear elasticity, with solutions computed using the finite element method. There are a range of options available when using the finite element method, in particular the polynomial degree of the basis functions used for interpolating position and pressure, and the type of element making up the mesh. The effect of these choices on the accuracy of the computed solution is investigated, using a selection of model problems motivated by typical deformations seen in soft tissue modelling. Model problems are set up with discontinuous material properties (as is the case for the breast), steeply changing gradients in the body force (as found in contracting cardiac tissue), and discontinuous first derivatives in the solution at the boundary, caused by a discontinuous applied force (as in the breast during mammography). It was found that the choice of pressure basis functions is vital in the presence of a material interface, higher-order schemes do not perform as well as may be expected when there are sharp gradients, and in general it is important to take the expected regularity of the solution into account when choosing a numerical scheme. © IMechE 2009.

  14. A comparison of numerical methods used for finite element modelling of soft tissue deformation

    KAUST Repository

    Pathmanathan, P

    2009-05-01

    Soft tissue deformation is often modelled using incompressible non-linear elasticity, with solutions computed using the finite element method. There are a range of options available when using the finite element method, in particular the polynomial degree of the basis functions used for interpolating position and pressure, and the type of element making up the mesh. The effect of these choices on the accuracy of the computed solution is investigated, using a selection of model problems motivated by typical deformations seen in soft tissue modelling. Model problems are set up with discontinuous material properties (as is the case for the breast), steeply changing gradients in the body force (as found in contracting cardiac tissue), and discontinuous first derivatives in the solution at the boundary, caused by a discontinuous applied force (as in the breast during mammography). It was found that the choice of pressure basis functions is vital in the presence of a material interface, higher-order schemes do not perform as well as may be expected when there are sharp gradients, and in general it is important to take the expected regularity of the solution into account when choosing a numerical scheme. © IMechE 2009.

  15. NMR imaging of soft tissue tumors

    International Nuclear Information System (INIS)

    Laval-Jeantet, M.; Tobolsk, F.; Delepine, N.; Delepine, G.; Roger, B.; Cabanis, E.A.

    1986-01-01

    Preliminary findings on NMR imaging of 30 soft tissue tumors demonstrated the indispensable value of this examination (particularly when a surface antenna is used) for preoperative investigation and diagnosis of tumoral recurrence when compared with other radiologic techniques. The possible potential of NMR imaging for characterization of tissues, apart from lipoma or liposarcoma, cannot be evaluated at the present time [fr

  16. Magnetic resonance imaging appearance of soft-tissue metastases: our experience at an orthopedic oncology center

    International Nuclear Information System (INIS)

    Sammon, Jennifer; Jain, Abhishek; Bleakney, Robert; Mohankumar, Rakesh

    2017-01-01

    To assess the prevalence and magnetic resonance imaging appearance of metastasis presenting as a soft-tissue mass. A retrospective chart review was performed on 51 patients who presented to an orthopedic oncology center with soft-tissue masses, with a histology-proven diagnosis of soft-tissue metastasis, over a 14-year period. Their magnetic resonance imaging, primary origin, and follow-up have been assessed. Soft-tissue metastasis was identified in patients ranging from 18 to 85 years old. Most (80%) of the masses were located deep to the deep fascia. In our cohort of patients, melanoma was the most common primary malignancy contributing to soft-tissue metastasis (21.8%). Among soft-tissue metastasis from solid organs, breast and lung were the most frequent (9.1% each). Five patients had soft-tissue metastases from an unknown primary. Imaging diagnosis of soft-tissue metastases is challenging as it can demonstrate imaging appearances similar to primary soft-tissue sarcoma. The presence of a known malignancy may not be evident in everyone, and even if available, histopathology will be necessary for diagnosis if this is the only site of recurrence/metastasis to differentiate from a primary soft-tissue sarcoma. Moreover, soft-tissue metastasis may be the initial presentation of a malignancy. Primary malignancies with soft-tissue metastasis carry a poor prognosis; hence, prompt diagnosis and management in essential. (orig.)

  17. Magnetic resonance imaging appearance of soft-tissue metastases: our experience at an orthopedic oncology center

    Energy Technology Data Exchange (ETDEWEB)

    Sammon, Jennifer; Jain, Abhishek; Bleakney, Robert; Mohankumar, Rakesh [Mount Sinai Hospital and University of Toronto, Division of Musculoskeletal Imaging, Joint Department of Medical Imaging, Toronto, Ontario (Canada)

    2017-04-15

    To assess the prevalence and magnetic resonance imaging appearance of metastasis presenting as a soft-tissue mass. A retrospective chart review was performed on 51 patients who presented to an orthopedic oncology center with soft-tissue masses, with a histology-proven diagnosis of soft-tissue metastasis, over a 14-year period. Their magnetic resonance imaging, primary origin, and follow-up have been assessed. Soft-tissue metastasis was identified in patients ranging from 18 to 85 years old. Most (80%) of the masses were located deep to the deep fascia. In our cohort of patients, melanoma was the most common primary malignancy contributing to soft-tissue metastasis (21.8%). Among soft-tissue metastasis from solid organs, breast and lung were the most frequent (9.1% each). Five patients had soft-tissue metastases from an unknown primary. Imaging diagnosis of soft-tissue metastases is challenging as it can demonstrate imaging appearances similar to primary soft-tissue sarcoma. The presence of a known malignancy may not be evident in everyone, and even if available, histopathology will be necessary for diagnosis if this is the only site of recurrence/metastasis to differentiate from a primary soft-tissue sarcoma. Moreover, soft-tissue metastasis may be the initial presentation of a malignancy. Primary malignancies with soft-tissue metastasis carry a poor prognosis; hence, prompt diagnosis and management in essential. (orig.)

  18. Soft tissue chondroma: a rare tumor presenting as a cutaneous nodule

    Directory of Open Access Journals (Sweden)

    Dibakar Podder

    2015-04-01

    Full Text Available Soft tissue chondroma (STC, also known as extraskeletal chondroma or chondroma of soft parts is a benign cartilaginous tumor which arise de novo from soft tissue. Also, it is an extremely rare entity predominantly involving extremities, especially fingers. A 26 year old male presented with 3 year history of swelling in left index finger. On local examination a hard 2 × 2 cm swelling was seen over the volar aspect of left 2nd proximal phalanx. Swelling was mobile on contraction of tendons. X-ray showed a soft tissue shadow on volar aspect of left second proximal phalanx. Histopathology showed a well encapsulated, hypo cellular nodule composed of benign chondrocytes surrounded by hyaline chondroid matrix. Nuclear pleomorphism, mitosis or necrosis was not seen. Based on radiological and histopathological findings a diagnosis of STC was made. STC should be considered in patients with slow growing, soft tissue masses.

  19. Advances in soft computing, intelligent robotics and control

    CERN Document Server

    Fullér, Robert

    2014-01-01

    Soft computing, intelligent robotics and control are in the core interest of contemporary engineering. Essential characteristics of soft computing methods are the ability to handle vague information, to apply human-like reasoning, their learning capability, and ease of application. Soft computing techniques are widely applied in the control of dynamic systems, including mobile robots. The present volume is a collection of 20 chapters written by respectable experts of the fields, addressing various theoretical and practical aspects in soft computing, intelligent robotics and control. The first part of the book concerns with issues of intelligent robotics, including robust xed point transformation design, experimental verification of the input-output feedback linearization of differentially driven mobile robot and applying kinematic synthesis to micro electro-mechanical systems design. The second part of the book is devoted to fundamental aspects of soft computing. This includes practical aspects of fuzzy rule ...

  20. Soft tissue cephalometric analysis applied to Himachali ethnic population

    Directory of Open Access Journals (Sweden)

    Isha Aggarwal

    2016-01-01

    Full Text Available Introduction: The modern society considers facial attractiveness as an important physical attribute. The great variance in soft tissue drape of the human face complicates accurate assessment of the soft tissue profile, and it is a known fact that facial features of different ethnic groups differ significantly. This study was undertaken to establish norms for Himachali ethnic population. Materials and Methods: The sample comprised lateral cephalograms taken in natural head position of 100 normal individuals (50 males, 50 females. The cephalograms were analyzed by Arnett soft tissue cephalometric analysis for orthodontic diagnosis and treatment planning. Student's t-test was used to compare the means of the two groups. Results: Statistically significant differences were found between Himachali males and females in certain key parameters. Males have thicker soft tissue structures and a more acute nasolabial angle than females. Males have longer faces and females have greater interlabial gap and maxillary incisor exposure. Males have more deep-set facial structures than females. Conclusions: Statistically significant differences were found between Himachali males and females in certain key parameters. Differences were also noted between other ethnic groups and Himachali faces.

  1. Can plantar soft tissue mechanics enhance prognosis of diabetic foot ulcer?

    Science.gov (United States)

    Naemi, R; Chatzistergos, P; Suresh, S; Sundar, L; Chockalingam, N; Ramachandran, A

    2017-04-01

    To investigate if the assessment of the mechanical properties of plantar soft tissue can increase the accuracy of predicting Diabetic Foot Ulceration (DFU). 40 patients with diabetic neuropathy and no DFU were recruited. Commonly assessed clinical parameters along with plantar soft tissue stiffness and thickness were measured at baseline using ultrasound elastography technique. 7 patients developed foot ulceration during a 12months follow-up. Logistic regression was used to identify parameters that contribute to predicting the DFU incidence. The effect of using parameters related to the mechanical behaviour of plantar soft tissue on the specificity, sensitivity, prediction strength and accuracy of the predicting models for DFU was assessed. Patients with higher plantar soft tissue thickness and lower stiffness at the 1st Metatarsal head area showed an increased risk of DFU. Adding plantar soft tissue stiffness and thickness to the model improved its specificity (by 3%), sensitivity (by 14%), prediction accuracy (by 5%) and prognosis strength (by 1%). The model containing all predictors was able to effectively (χ 2 (8, N=40)=17.55, P<0.05) distinguish between the patients with and without DFU incidence. The mechanical properties of plantar soft tissue can be used to improve the predictability of DFU in moderate/high risk patients. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. A mummified duck-billed dinosaur with a soft-tissue cock's comb.

    Science.gov (United States)

    Bell, Phil R; Fanti, Federico; Currie, Philip J; Arbour, Victoria M

    2014-01-06

    Among living vertebrates, soft tissues are responsible for labile appendages (combs, wattles, proboscides) that are critical for activities ranging from locomotion to sexual display [1]. However, soft tissues rarely fossilize, and such soft-tissue appendages are unknown for many extinct taxa, including dinosaurs. Here we report a remarkable "mummified" specimen of the hadrosaurid dinosaur Edmontosaurus regalis from the latest Cretaceous Wapiti Formation, Alberta, Canada, that preserves a three-dimensional cranial crest (or "comb") composed entirely of soft tissue. Previously, crest function has centered on the hypertrophied nasal passages of lambeosaurine hadrosaurids, which acted as resonance chambers during vocalization [2-4]. The fleshy comb in Edmontosaurus necessitates an alternative explanation most likely related to either social signaling or sexual selection [5-7]. This discovery provides the first view of bizarre, soft-tissue signaling structures in a dinosaur and provides additional evidence for social behavior. Crest evolution within Hadrosaurinae apparently culminated in the secondary loss of the bony crest at the terminal Cretaceous; however, the new specimen indicates that cranial ornamentation was in fact not lost but substituted in Edmontosaurus by a fleshy display structure. It also implies that visual display played a key role in the evolution of hadrosaurine crests and raises the possibility of similar soft-tissue structures among other dinosaurs. Copyright © 2014 Elsevier Ltd. All rights reserved.

  3. Imaging of the hip joint. Computed tomography versus magnetic resonance imaging

    Science.gov (United States)

    Lang, P.; Genant, H. K.; Jergesen, H. E.; Murray, W. R.

    1992-01-01

    The authors reviewed the applications and limitations of computed tomography (CT) and magnetic resonance (MR) imaging in the assessment of the most common hip disorders. Magnetic resonance imaging is the most sensitive technique in detecting osteonecrosis of the femoral head. Magnetic resonance reflects the histologic changes associated with osteonecrosis very well, which may ultimately help to improve staging. Computed tomography can more accurately identify subchondral fractures than MR imaging and thus remains important for staging. In congenital dysplasia of the hip, the position of the nonossified femoral head in children less than six months of age can only be inferred by indirect signs on CT. Magnetic resonance imaging demonstrates the cartilaginous femoral head directly without ionizing radiation. Computed tomography remains the imaging modality of choice for evaluating fractures of the hip joint. In some patients, MR imaging demonstrates the fracture even when it is not apparent on radiography. In neoplasm, CT provides better assessment of calcification, ossification, and periosteal reaction than MR imaging. Magnetic resonance imaging, however, represents the most accurate imaging modality for evaluating intramedullary and soft-tissue extent of the tumor and identifying involvement of neurovascular bundles. Magnetic resonance imaging can also be used to monitor response to chemotherapy. In osteoarthrosis and rheumatoid arthritis of the hip, both CT and MR provide more detailed assessment of the severity of disease than conventional radiography because of their tomographic nature. Magnetic resonance imaging is unique in evaluating cartilage degeneration and loss, and in demonstrating soft-tissue alterations such as inflammatory synovial proliferation.

  4. Digital radiography

    International Nuclear Information System (INIS)

    Kusano, Shoichi

    1993-01-01

    Firstly, from an historic point of view, fundamental concepts on digital imaging were reviewed to provide a foundation for discussion of digital radiography. Secondly, this review summarized the results of ongoing research in computed radiography that replaces the conventional film-screen system with a photo-stimulable phosphor plate; and thirdly, image quality, radiation protection, and image processing techniques were discussed with emphasis on picture archiving and communication system environment as our final goal. Finally, future expansion of digital radiography was described based on the present utilization of computed tomography at the National Defense Medical College Hospital. (author) 60 refs

  5. Real-time simulation of the nonlinear visco-elastic deformations of soft tissues.

    Science.gov (United States)

    Basafa, Ehsan; Farahmand, Farzam

    2011-05-01

    Mass-spring-damper (MSD) models are often used for real-time surgery simulation due to their fast response and fairly realistic deformation replication. An improved real time simulation model of soft tissue deformation due to a laparoscopic surgical indenter was developed and tested. The mechanical realization of conventional MSD models was improved using nonlinear springs and nodal dampers, while their high computational efficiency was maintained using an adapted implicit integration algorithm. New practical algorithms for model parameter tuning, collision detection, and simulation were incorporated. The model was able to replicate complex biological soft tissue mechanical properties under large deformations, i.e., the nonlinear and viscoelastic behaviors. The simulated response of the model after tuning of its parameters to the experimental data of a deer liver sample, closely tracked the reference data with high correlation and maximum relative differences of less than 5 and 10%, for the tuning and testing data sets respectively. Finally, implementation of the proposed model and algorithms in a graphical environment resulted in a real-time simulation with update rates of 150 Hz for interactive deformation and haptic manipulation, and 30 Hz for visual rendering. The proposed real time simulation model of soft tissue deformation due to a laparoscopic surgical indenter was efficient, realistic, and accurate in ex vivo testing. This model is a suitable candidate for testing in vivo during laparoscopic surgery.

  6. Drugs Approved for Soft Tissue Sarcoma

    Science.gov (United States)

    This page lists cancer drugs approved by the Food and Drug Administration (FDA) for soft tissue sarcoma. The list includes generic names and brand names. The drug names link to NCI's Cancer Drug Information summaries.

  7. Skin and soft-tissue infec tions

    African Journals Online (AJOL)

    2010-06-01

    Jun 1, 2010 ... Patients with skin and soft-tissue infections (SSTIs) often initially present to family physicians. ..... Nosocomial infections are often caused by MRSA or mixed .... site infections are good hand hygiene, good surgical technique.

  8. THE POTENTIAL VALUE OF ULTRASOUND IN DIAGNOSIS OF SOFT TISSUE SARCOMA (LITERATURE REVIEW

    Directory of Open Access Journals (Sweden)

    I. G. Frolova

    2015-01-01

    Full Text Available Literature data on the potential value of ultrasound imaging in diagnosis of soft tissue sarcoma were analyzed. Ultrasound in B-regime was used to assess the extent of soft tissue sarcoma, Doppler ultrasonography was used to study tumor vascularization and sonoelastography was useful to differentiate benign from malignant tumors of soft tissues. The analysis of diagnostic value of ultrasound in detection of soft tissue lesions was carried out.  Criteria characterizing various histological types of tumors were identified.

  9. Weak light emission of soft tissues induced by heating

    Science.gov (United States)

    Spinelli, Antonello E.; Durando, Giovanni; Boschi, Federico

    2018-04-01

    The main goal of this work is to show that soft tissue interaction with high-intensity focused ultrasound (HIFU) or direct heating leads to a weak light emission detectable using a small animal optical imaging system. Our results show that the luminescence signal is detectable after 30 min of heating, resembling the time scale of delayed luminescence. The imaging of a soft tissue after heating it using an HIFU field shows that the luminescence pattern closely matches the shape of the cone typical of the HIFU beam. We conclude that heating a soft tissue using two different sources leads to the emission of a weak luminescence signal from the heated region with a decay half-life of a few minutes (4 to 6 min). The origin of such light emission needs to be further investigated.

  10. Carbon ion radiotherapy in bone and soft tissue sarcomas

    International Nuclear Information System (INIS)

    Kamada, Tadashi; Imai, Reiko; Kagei, Kenji; Tsuji, Hiroshi; Yanagi, Takeshi; Ishikawa, Hitoshi; Tsujii, Hirohiko

    2006-01-01

    The Heavy Ion Medical Accelerator in Chiba (HIMAC) is the world's first heavy ion accelerator complex dedicated to medical use in a hospital environment. Heavy ions have superior depth-dose distribution and greater cell-killing capability. In June 1996, clinical research for the treatment of bone and soft tissue sarcomas was begun using carbon ions generated by the HIMAC. As of February 2006, a total of the 278 patients with bone and soft tissue sarcoma had been enrolled into the clinical trial. Most of the patients had locally advanced and/or medically inoperable tumors. The clinical trial revealed that carbon ion radiotherapy provided definite local control and offered a survival advantage without unacceptable morbidity in bone and soft tissue sarcomas that were hard to cure with other modalities. (author)

  11. Fuzzy systems and soft computing in nuclear engineering

    International Nuclear Information System (INIS)

    Ruan, D.

    2000-01-01

    This book is an organized edited collection of twenty-one contributed chapters covering nuclear engineering applications of fuzzy systems, neural networks, genetic algorithms and other soft computing techniques. All chapters are either updated review or original contributions by leading researchers written exclusively for this volume. The volume highlights the advantages of applying fuzzy systems and soft computing in nuclear engineering, which can be viewed as complementary to traditional methods. As a result, fuzzy sets and soft computing provide a powerful tool for solving intricate problems pertaining in nuclear engineering. Each chapter of the book is self-contained and also indicates the future research direction on this topic of applications of fuzzy systems and soft computing in nuclear engineering. (orig.)

  12. Computed and conventional chest radiography: a comparison of image quality and radiation dose

    International Nuclear Information System (INIS)

    Ramli, K.; Abdullah, B.J.J.; Ng, K-H.; Hussain, A.F.; Mahmud, R.

    2005-01-01

    The aim of this study was to compare the image quality and entrance skin dose (ESD) for film-screen and computed chest radiography. Analysis of the image quality and dose on chest radiography was carried out on a conventional X-ray unit using film-screen, storage phosphor plates and selenium drum direct chest radiography. For each receptor, ESD was measured in 60 patients using thermoluminescent dosemeters. Images were printed on 35 x 43 cm films. Image quality was assessed subjectively by evaluation of anatomic features and estimation of the image quality, following the guidelines established by the protocols of the Commission of the European Communities. There was no statistically significant difference noted between the computed and conventional images (Wilcoxon rank sum test, P>0.05). Imaging of the mediastinum and peripheral lung structures were better visualized with the storage phosphor and selenium drum technique than with the film-screen combination. The patients' mean ESD for chest radiography using the storage phosphor, film-screen combination and selenium drum was 0.20, 0.20 and 0.25 mGy, respectively, with no statistically significant difference with P > 0.05 (χ 2 tests) Copyright (2005) Blackwell Publishing Asia Pty Ltd

  13. Indentation and Observation of Anisotropic Soft Tissues Using an Indenter Device

    Directory of Open Access Journals (Sweden)

    Parinaz ASHRAFI

    2015-01-01

    Full Text Available Soft tissues of human body have complex structures and different mechanical behaviors than those of traditional engineering materials. There is a great urge to understand tissue behavior of human body. Experimental data is needed for improvement of soft tissue modeling and advancement in implants and prosthesis, as well as diagnosis of diseases. Mechanical behavior and responses change when tissue loses its liveliness and viability. One of the techniques for soft tissue testing is indentation, which is applied on live tissue in its physiological environment. Indentation affords several advantages over other types of tests such as uniaxial tension, biaxial tension, and simple shear and suction, thus it is of interest to develop new indentation techniques from which more valid data can be extracted. In this study a new indenter device was designed and constructed. Displacement and force rate cyclic loading, and relaxation experiments were conducted on human arm. The in-vivo force rate controlled cyclic loading test method which is novel is compared with the traditional displacement controlled cyclic loading tests. Anisotropic behavior of tissue cannot be determined by axisymmetric tips, therefore ellipsoid tips were used for examining anisotropy and inplane material direction of bulk soft tissues

  14. Soft-tissue volumetric changes following monobloc distraction procedure: analysis using digital three-dimensional photogrammetry system (3dMD).

    Science.gov (United States)

    Chan, Fuan Chiang; Kawamoto, Henry K; Federico, Christina; Bradley, James P

    2013-03-01

    We have previously reported that monobloc advancement by distraction osteogenesis resulted in decreased morbidity and greater advancement with less relapse compared with acute monobloc advancement with bone grafting. In this study, we examine the three-dimensional (3D) volumetric soft-tissue changes in monobloc distraction.Patients with syndromic craniosynostosis who underwent monobloc distraction from 2002 to 2010 at University of California-Los Angeles Craniofacial Center were studied (n = 12). We recorded diagnosis, indications for the surgery, and volumetric changes for skeletal and soft-tissue midface structures (preoperative/postoperative [6 weeks]/follow-up [>1 year]). Computed tomography scans and a digital 3D photogrammetry system were used for image analysis.Patients ranged from 6 to 14 years of age (mean, 10.1 years) at the time of the operation (follow-up 2-11 years); mean distraction advancement was 19.4 mm (range, 14-25 mm). There was a mean increase in the 3D volumetric soft-tissue changes: 99.5 ± 4.0 cm(3) (P < 0.05) at 6 weeks and 94.9 ± 3.6 cm(3) (P < 0.05) at 1-year follow-up. When comparing soft-tissue changes at 6 weeks postoperative to 1-year follow-up, there were minimal relapse changes. The overall mean 3D skeletal change was 108.9 ± 4.2 cm. For every 1 cm of skeletal gain, there was 0.78 cm(3) of soft-tissue gain.Monobloc advancement by distraction osteogenesis using internal devices resulted in increased volumetric soft-tissue changes, which remained stable at 1 year. The positive linear correlation between soft-tissue increments and bony advancement can be incorporated during the planning of osteotomies to achieve optimum surgical outcomes with monobloc distraction.

  15. Soft tissue chondroma: a case report

    Directory of Open Access Journals (Sweden)

    Haeri H

    2011-04-01

    Full Text Available "n 800x600 Normal 0 false false false EN-US X-NONE AR-SA MicrosoftInternetExplorer4 /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-parent:""; mso-padding-alt:0in 5.4pt 0in 5.4pt; mso-para-margin:0in; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:10.0pt; font-family:"Times New Roman","serif";} Background: Soft tissue chondroma is a rare slow-growing benign cartilage forming tumor. Tumors of this kind arise from the relative mesenchymal tissue and have tendency to occur in the fingers and toes. Due to its rarity, this tumor is likely to go undiagnosed. Histopathological examination usually reveals the correct diagnosis."n"nCase presentation: Hereby, we report a case of soft tissue chondroma in a 27 year-old woman presented with a slow-growing mass in the volar aspect of her right hand. The tumor had developed over a 7-month period. The skeletal system was unremarkable on X-ray evaluation. The lesion was excised and the histopathological findings revealed a well-delineated cartilaginous neoplasm with lobular pattern. The tumor was composed of mature chondrocytes without atypia and the findings were compatible with chondroma."n"nConclusion: There are various hypotheses about the etiology of soft tissue chondromas and their microscopic findings are variable. They have a good prognosis. Recurrence is rare and malignant transformation has not been reported yet.

  16. Photoactivated Composite Biomaterial for Soft Tissue Restoration in Rodents and in Humans

    OpenAIRE

    Hillel, Alexander T.; Unterman, Shimon; Nahas, Zayna; Reid, Branden; Coburn, Jeannine M.; Axelman, Joyce; Chae, Jemin J.; Guo, Qiongyu; Trow, Robert; Thomas, Andrew; Hou, Zhipeng; Lichtsteiner, Serge; Sutton, Damon; Matheson, Christine; Walker, Patricia

    2011-01-01

    Soft tissue reconstruction often requires multiple surgical procedures that can result in scars and disfiguration. Facial soft tissue reconstruction represents a clinical challenge because even subtle deformities can severely affect an individual’s social and psychological function. We therefore developed a biosynthetic soft tissue replacement composed of poly(ethylene glycol) (PEG) and hyaluronic acid (HA) that can be injected and photocrosslinked in situ with transdermal ligh...

  17. Case report 488: Post-traumatic myositis ossificans mimicking a soft tissue neoplasm

    International Nuclear Information System (INIS)

    Ackerman, L.; Ramamurthy, S.; Jablokow, V.; Van Drunen, M.; Kaplan, E.

    1988-01-01

    A case of post-traumatic myosotis ossificans (MO) in a young man with only a vague history of preceding physical trauma to the area of the lesion was presented. Imaging modalities, including plain film radiography, CT, contrast angiography and bone scintigraphy, could not exclude a malignancy with a reliable degree of certainty. The biopsy specimen was consistent with MO but could easily be misinterpreted as a sarcomatous lesion. A diagnosis of MO was only established by a scrupulous analysis of all clinical, radiological, scintigraphic and microscopic findings and unnecessary extensive surgery for a malignancy was avoided. The correlative radiological and pathological features in distinguishing post-traumatic myositis ossificans from such lesions as soft tissue osteosarcoma or parosteal osteosarcoma were described and the meaning of the term zoning phenomenon was elucidated. It was emphasized that utilizing the zonal phenomenon (both pathologically and radiologically) ensures a correct diagnosis most of the time. However, it must be emphasized that this zoning phenomenon is not established in the early stages of post-traumatic myositis ossificans. (oerig./MG)

  18. Optimized path planning for soft tissue resection via laser vaporization

    Science.gov (United States)

    Ross, Weston; Cornwell, Neil; Tucker, Matthew; Mann, Brian; Codd, Patrick

    2018-02-01

    Robotic and robotic-assisted surgeries are becoming more prevalent with the promise of improving surgical outcomes through increased precision, reduced operating times, and minimally invasive procedures. The handheld laser scalpel in neurosurgery has been shown to provide a more gentle approach to tissue manipulation on or near critical structures over classical tooling, though difficulties of control have prevented large scale adoption of the tool. This paper presents a novel approach to generating a cutting path for the volumetric resection of tissue using a computer-guided laser scalpel. A soft tissue ablation simulator is developed and used in conjunction with an optimization routine to select parameters which maximize the total resection of target tissue while minimizing the damage to surrounding tissue. The simulator predicts the ablative properties of tissue from an interrogation cut for tuning and simulates the removal of a tumorous tissue embedded on the surface of healthy tissue using a laser scalpel. We demonstrate the ability to control depth and smoothness of cut using genetic algorithms to optimize the ablation parameters and cutting path. The laser power level, cutting rate and spacing between cuts are optimized over multiple surface cuts to achieve the desired resection volumes.

  19. Computed radiography simulation using the Monte Carlo code MCNPX

    International Nuclear Information System (INIS)

    Correa, S.C.A.; Souza, E.M.; Silva, A.X.; Lopes, R.T.

    2009-01-01

    Simulating x-ray images has been of great interest in recent years as it makes possible an analysis of how x-ray images are affected owing to relevant operating parameters. In this paper, a procedure for simulating computed radiographic images using the Monte Carlo code MCNPX is proposed. The sensitivity curve of the BaFBr image plate detector as well as the characteristic noise of a 16-bit computed radiography system were considered during the methodology's development. The results obtained confirm that the proposed procedure for simulating computed radiographic images is satisfactory, as it allows obtaining results comparable with experimental data. (author)

  20. Computed radiography simulation using the Monte Carlo code MCNPX

    Energy Technology Data Exchange (ETDEWEB)

    Correa, S.C.A. [Programa de Engenharia Nuclear/COPPE, Universidade Federal do Rio de Janeiro, Ilha do Fundao, Caixa Postal 68509, 21945-970, Rio de Janeiro, RJ (Brazil); Centro Universitario Estadual da Zona Oeste (CCMAT)/UEZO, Av. Manuel Caldeira de Alvarenga, 1203, Campo Grande, 23070-200, Rio de Janeiro, RJ (Brazil); Souza, E.M. [Programa de Engenharia Nuclear/COPPE, Universidade Federal do Rio de Janeiro, Ilha do Fundao, Caixa Postal 68509, 21945-970, Rio de Janeiro, RJ (Brazil); Silva, A.X., E-mail: ademir@con.ufrj.b [PEN/COPPE-DNC/Poli CT, Universidade Federal do Rio de Janeiro, Ilha do Fundao, Caixa Postal 68509, 21945-970, Rio de Janeiro, RJ (Brazil); Cassiano, D.H. [Instituto de Radioprotecao e Dosimetria/CNEN Av. Salvador Allende, s/n, Recreio, 22780-160, Rio de Janeiro, RJ (Brazil); Lopes, R.T. [Programa de Engenharia Nuclear/COPPE, Universidade Federal do Rio de Janeiro, Ilha do Fundao, Caixa Postal 68509, 21945-970, Rio de Janeiro, RJ (Brazil)

    2010-09-15

    Simulating X-ray images has been of great interest in recent years as it makes possible an analysis of how X-ray images are affected owing to relevant operating parameters. In this paper, a procedure for simulating computed radiographic images using the Monte Carlo code MCNPX is proposed. The sensitivity curve of the BaFBr image plate detector as well as the characteristic noise of a 16-bit computed radiography system were considered during the methodology's development. The results obtained confirm that the proposed procedure for simulating computed radiographic images is satisfactory, as it allows obtaining results comparable with experimental data.

  1. Digital radiography: are the manufacturers' settings too high? Optimisation of the Kodak digital radiography system with aid of the computed radiography dose index

    International Nuclear Information System (INIS)

    Peters, Sinead E.; Brennan, Patrick C.

    2002-01-01

    Manufacturers offer exposure indices as a safeguard against overexposure in computed radiography, but the basis for recommended values is unclear. This study establishes an optimum exposure index to be used as a guideline for a specific CR system to minimise radiation exposures for computed mobile chest radiography, and compares this with manufacturer guidelines and current practice. An anthropomorphic phantom was employed to establish the minimum milliamperes consistent with acceptable image quality for mobile chest radiography images. This was found to be 2 mAs. Consecutively, 10 patients were exposed with this optimised milliampere value and 10 patients were exposed with the 3.2 mAs routinely used in the department of the study. Image quality was objectively assessed using anatomical criteria. Retrospective analyses of 717 exposure indices recorded over 2 months from mobile chest examinations were performed. The optimised milliampere value provided a significant reduction of the average exposure index from 1840 to 1570 (p<0.0001). This new ''optimum'' exposure index is substantially lower than manufacturer guidelines of 2000 and significantly lower than exposure indices from the retrospective study (1890). Retrospective data showed a significant increase in exposure indices if the examination was performed out of hours. The data provided by this study emphasise the need for clinicians and personnel to consider establishing their own optimum exposure indices for digital investigations rather than simply accepting manufacturers' guidelines. Such an approach, along with regular monitoring of indices, may result in a substantial reduction in patient exposure. (orig.)

  2. Computed radiography systems performance evaluation

    International Nuclear Information System (INIS)

    Xavier, Clarice C.; Nersissian, Denise Y.; Furquim, Tania A.C.

    2009-01-01

    The performance of a computed radiography system was evaluated, according to the AAPM Report No. 93. Evaluation tests proposed by the publication were performed, and the following nonconformities were found: imaging p/ate (lP) dark noise, which compromises the clinical image acquired using the IP; exposure indicator uncalibrated, which can cause underexposure to the IP; nonlinearity of the system response, which causes overexposure; resolution limit under the declared by the manufacturer and erasure thoroughness uncalibrated, impairing structures visualization; Moire pattern visualized at the grid response, and IP Throughput over the specified by the manufacturer. These non-conformities indicate that digital imaging systems' lack of calibration can cause an increase in dose in order that image prob/ems can be so/ved. (author)

  3. Extremity Soft Tissue Sarcoma: A Review of 19 Cases. | Eyesan ...

    African Journals Online (AJOL)

    Background: Although soft tissue sarcoma is a rare tumour, it accounts for a significant proportion of malignancies seen in many orthopaedic practices. The objectives of this study are to evaluate the pattern of presentation of extremity soft tissue sarcoma and the treatment outcome in our patients. Method: This is a 3 year ...

  4. Digital computed radiography in industrial X-ray testing

    International Nuclear Information System (INIS)

    Osterloh, K.; Onel, Y.; Zscherpel, U.; Ewert, U.

    2001-01-01

    Computed radiography is used for X-ray testing in many industrial applications. There are different systems depending on the application, e.g. fast systems for detection of material inhomogeneities and slower systems with higher local resolution for detection of cracks and fine details, e.g. in highly stressed areas or in welded seams. The method is more dynamic than film methods, and digital image processing is possible during testing [de

  5. [Inconformity between soft tissue defect and bony defect in incomplete cleft palate].

    Science.gov (United States)

    Zhou, Xia; Ma, Lian

    2014-12-01

    To evaluate the inconformity between soft tissue defect and bony defect by observing the cleft extent of palate with complete secondary palate bony cleft in incomplete cleft palate patient. The patients with incomplete cleft palate treated in Hospital of Stomatology Peking University from July 2012 to June 2013 were reviewed, of which 75 cases with complete secondary palate bony cleft were selected in this study. The CT scan and intraoral photograph were taken before operation. The patients were classified as four types according to the extent of soft tissue defect. Type 1: soft tissue defect reached incisive foremen region, Type 2 was hard and soft cleft palate, Type 3 soft cleft palate and Type 4 submucous cleft palate. Type 1 was defined as conformity group (CG). The other three types were defined as inconformity group (ICG) and divided into three subgroups (ICG-I), (ICG-II) and (ICG-III). Fifty-seven patients were in ICG group, and the rate of inconformity was 76% (57/75). The percentage of ICG-I, ICG-II and ICG-III was 47% (27/57), 23% (13/57) and 30% (17/57), respevtively. There are different types of soft tissue deformity with complete secondary palate bony cleft. The inconformity between soft tissue and hard tissue defect exits in 3/4 of isolated cleft palate patients.

  6. Reptile Soft Tissue Surgery.

    Science.gov (United States)

    Di Girolamo, Nicola; Mans, Christoph

    2016-01-01

    The surgical approach to reptiles can be challenging. Reptiles have unique physiologic, anatomic, and pathologic differences. This may result in frustrating surgical experiences. However, recent investigations provided novel, less invasive, surgical techniques. The purpose of this review was to describe the technical aspects behind soft tissue surgical techniques that have been used in reptiles, so as to provide a general guideline for veterinarians working with reptiles. Copyright © 2016 Elsevier Inc. All rights reserved.

  7. Finite-element modeling of soft tissue rolling indentation.

    Science.gov (United States)

    Sangpradit, Kiattisak; Liu, Hongbin; Dasgupta, Prokar; Althoefer, Kaspar; Seneviratne, Lakmal D

    2011-12-01

    We describe a finite-element (FE) model for simulating wheel-rolling tissue deformations using a rolling FE model (RFEM). A wheeled probe performing rolling tissue indentation has proven to be a promising approach for compensating for the loss of haptic and tactile feedback experienced during robotic-assisted minimally invasive surgery (H. Liu, D. P. Noonan, B. J. Challacombe, P. Dasgupta, L. D. Seneviratne, and K. Althoefer, "Rolling mechanical imaging for tissue abnormality localization during minimally invasive surgery, " IEEE Trans. Biomed. Eng., vol. 57, no. 2, pp. 404-414, Feb. 2010; K. Sangpradit, H. Liu, L. Seneviratne, and K. Althoefer, "Tissue identification using inverse finite element analysis of rolling indentation," in Proc. IEEE Int. Conf. Robot. Autom. , Kobe, Japan, 2009, pp. 1250-1255; H. Liu, D. Noonan, K. Althoefer, and L. Seneviratne, "The rolling approach for soft tissue modeling and mechanical imaging during robot-assisted minimally invasive surgery," in Proc. IEEE Int. Conf. Robot. Autom., May 2008, pp. 845-850; H. Liu, P. Puangmali, D. Zbyszewski, O. Elhage, P. Dasgupta, J. S. Dai, L. Seneviratne, and K. Althoefer, "An indentation depth-force sensing wheeled probe for abnormality identification during minimally invasive surgery," Proc. Inst. Mech. Eng., H, vol. 224, no. 6, pp. 751-63, 2010; D. Noonan, H. Liu, Y. Zweiri, K. Althoefer, and L. Seneviratne, "A dual-function wheeled probe for tissue viscoelastic property identification during minimally invasive surgery," in Proc. IEEE Int. Conf. Robot. Autom. , 2008, pp. 2629-2634; H. Liu, J. Li, Q. I. Poon, L. D. Seneviratne, and K. Althoefer, "Miniaturized force indentation-depth sensor for tissue abnormality identification," IEEE Int. Conf. Robot. Autom., May 2010, pp. 3654-3659). A sound understanding of wheel-tissue rolling interaction dynamics will facilitate the evaluation of signals from rolling indentation. In this paper, we model the dynamic interactions between a wheeled probe and a

  8. Automatic bone detection and soft tissue aware ultrasound-CT registration for computer-aided orthopedic surgery.

    Science.gov (United States)

    Wein, Wolfgang; Karamalis, Athanasios; Baumgartner, Adrian; Navab, Nassir

    2015-06-01

    The transfer of preoperative CT data into the tracking system coordinates within an operating room is of high interest for computer-aided orthopedic surgery. In this work, we introduce a solution for intra-operative ultrasound-CT registration of bones. We have developed methods for fully automatic real-time bone detection in ultrasound images and global automatic registration to CT. The bone detection algorithm uses a novel bone-specific feature descriptor and was thoroughly evaluated on both in-vivo and ex-vivo data. A global optimization strategy aligns the bone surface, followed by a soft tissue aware intensity-based registration to provide higher local registration accuracy. We evaluated the system on femur, tibia and fibula anatomy in a cadaver study with human legs, where magnetically tracked bone markers were implanted to yield ground truth information. An overall median system error of 3.7 mm was achieved on 11 datasets. Global and fully automatic registration of bones aquired with ultrasound to CT is feasible, with bone detection and tracking operating in real time for immediate feedback to the surgeon.

  9. Devising tissue ingrowth metrics: a contribution to the computational characterization of engineered soft tissue healing.

    Science.gov (United States)

    Alves, Antoine; Attik, Nina; Bayon, Yves; Royet, Elodie; Wirth, Carine; Bourges, Xavier; Piat, Alexis; Dolmazon, Gaëlle; Clermont, Gaëlle; Boutrand, Jean-Pierre; Grosgogeat, Brigitte; Gritsch, Kerstin

    2018-03-14

    differences not detected by the semi-quantitative assessment, demonstrating the importance of quantitative analysis in the performance evaluation of soft tissue healing. This automated and supervised method reduced operator dependency and proved to be simple, sensitive, cost-effective and time-effective. It supports objective therapeutic comparisons and helps to elucidate regeneration and the dynamics of a functional tissue.

  10. 6th International Workshop Soft Computing Applications

    CERN Document Server

    Jain, Lakhmi; Kovačević, Branko

    2016-01-01

    These volumes constitute the Proceedings of the 6th International Workshop on Soft Computing Applications, or SOFA 2014, held on 24-26 July 2014 in Timisoara, Romania. This edition was organized by the University of Belgrade, Serbia in conjunction with Romanian Society of Control Engineering and Technical Informatics (SRAIT) - Arad Section, The General Association of Engineers in Romania - Arad Section, Institute of Computer Science, Iasi Branch of the Romanian Academy and IEEE Romanian Section.                 The Soft Computing concept was introduced by Lotfi Zadeh in 1991 and serves to highlight the emergence of computing methodologies in which the accent is on exploiting the tolerance for imprecision and uncertainty to achieve tractability, robustness and low solution cost. Soft computing facilitates the use of fuzzy logic, neurocomputing, evolutionary computing and probabilistic computing in combination, leading to the concept of hybrid intelligent systems.        The combination of ...

  11. A Simulation-Based Soft Error Estimation Methodology for Computer Systems

    OpenAIRE

    Sugihara, Makoto; Ishihara, Tohru; Hashimoto, Koji; Muroyama, Masanori

    2006-01-01

    This paper proposes a simulation-based soft error estimation methodology for computer systems. Accumulating soft error rates (SERs) of all memories in a computer system results in pessimistic soft error estimation. This is because memory cells are used spatially and temporally and not all soft errors in them make the computer system faulty. Our soft-error estimation methodology considers the locations and the timings of soft errors occurring at every level of memory hierarchy and estimates th...

  12. Advance Trends in Soft Computing

    CERN Document Server

    Kreinovich, Vladik; Kacprzyk, Janusz; WCSC 2013

    2014-01-01

    This book is the proceedings of the 3rd World Conference on Soft Computing (WCSC), which was held in San Antonio, TX, USA, on December 16-18, 2013. It presents start-of-the-art theory and applications of soft computing together with an in-depth discussion of current and future challenges in the field, providing readers with a 360 degree view on soft computing. Topics range from fuzzy sets, to fuzzy logic, fuzzy mathematics, neuro-fuzzy systems, fuzzy control, decision making in fuzzy environments, image processing and many more. The book is dedicated to Lotfi A. Zadeh, a renowned specialist in signal analysis and control systems research who proposed the idea of fuzzy sets, in which an element may have a partial membership, in the early 1960s, followed by the idea of fuzzy logic, in which a statement can be true only to a certain degree, with degrees described by numbers in the interval [0,1]. The performance of fuzzy systems can often be improved with the help of optimization techniques, e.g. evolutionary co...

  13. The effect of hard tissue surgical changes on soft tissue displacement: a pilot CBCT study

    Directory of Open Access Journals (Sweden)

    Leonardo Koerich

    Full Text Available ABSTRACT Introduction: This pilot study had as main objective to test the reliability of a new method to evaluate orthognathic surgery outcomes and also, to understand the effect of hard tissue changes on soft tissue displacement. Methods: The sample consisted of eight patients that underwent bimaxillary advancement and had CBCT at two time points (before surgery and 6-8 months follow-up. Voxel-based cranial base superimposition was used to register the scans. A different technique of iterative closest point (ICP was used to measure and correlate the changes. The average displacement of 15 areas (4 hard tissue and 11 soft tissue were measured twice. Results: ICC was > 0.99 for all areas. Changes in the tip of the nose did not correlate with changes in any maxillary area, whereas soft tissue A point, A point and upper lips had correlation with several areas. The highest correlation for the maxilla was between the upper lip and the left/right supra cheilion (p< 0.001, r= 0.91 and p< 0.001, r= 0.93, respectively. In the mandible, the majority of the correlations involved soft tissue pogonion, pogonion and lower incisors, with the strongest one between pogonion and lower incisors (p< 0.001, r= 0.98. Conclusion: With the proper case selection, ICP is a reliable method that can be used to assess three-dimensional changes.

  14. Soft tissue masses of extremities: MR findings

    Energy Technology Data Exchange (ETDEWEB)

    Son, Seok Hyun; Yang, Seoung Oh; Choi, Jong Chul; Park, Byeong Ho; Lee, Ki Nam; Choi, Sun Seob; Chung, Duck Hwan [Dong-A University College of Medicine, Pusan (Korea, Republic of)

    1993-11-15

    To evaluate MR findings of soft tissue masses in extremities and to find the helpful findings of distinguish benignity from malignancy, 28 soft tissue masses (22 benign and 6 malignant) in extremities were reviewed. TI-weighted, proton density, T2-weighted and Gd-DTPA enhanced images were obtained. MR images allowed a specific diagnosis in large number of benign masses, such as hemangioma(8/9), lipoma(2/2), angiolipoma(1/1), epidermoid cyst(2/2), myositis ossificans(1/1), synovial chondromatosis(1/1) and pigmented villonodular synovitis(1/2). Specific diagnosis was difficult in the rest of the masses including malignancy. However, inhomogeneous signal intensities with necrosis and inhomogeneous enhancement may suggest malignant masses.

  15. Clinical Evaluation of a Dual-Side Readout Technique Computed Radiography System in Chest Radiography of Premature Neonates

    International Nuclear Information System (INIS)

    Carlander, A.; Hansson, J.; Soederberg, J.; Steneryd, K.; Baath, M.

    2008-01-01

    Background: Recently, the dual-side readout technique has been introduced in computed radiography, leading to an increase in detective quantum efficiency (DQE) compared with the single-side readout technique. Purpose: To evaluate if the increase in DQE with the dual-side readout technique results in a higher clinical image quality in chest radiography of premature neonates at no increase in radiation dose. Material and Methods: Twenty-four chest radiographs of premature neonates were collected from both a single-side readout technique system and a double-side readout technique system. The images were processed in the same image-processing station in order for the comparison to be only dependent on the difference in readout technique. Five radiologists rated the fulfillment of four image quality criteria, which were based on important anatomical landmarks. The given ratings were analyzed using visual grading characteristics (VGC) analysis. Results: The VGC analysis showed that the reproduction of the carina with the main bronchi and the thoracic vertebrae behind the heart was better with the dual-side readout technique, whereas no significant difference for the reproduction of the central vessels or the peripheral vessels could be observed. Conclusions: The results indicate that the higher DQE of the dual-side readout technique leads to higher clinical image quality in chest radiography of premature neonates at no increase in radiation dose. Keywords: Digital radiography; lung; observer performance; pediatrics; thorax

  16. The study on facial soft tissue thickness using Han population in Xinjiang.

    Science.gov (United States)

    Wang, Jierui; Zhao, Xi; Mi, Congbo; Raza, Iqbal

    2016-09-01

    Facial profile is an important aspect in physical anthropology, forensic science, and cosmetic research. Thus, facial soft tissue measurement technology plays a significant role in facial restoration. A considerable amount of work has investigated facial soft tissue thickness, which significantly varies according to gender, age, and race. However, only few studies have considered the nutritional status of the investigated individuals. Moreover, no sufficient research among Chinese ethnic groups, particularly Xinjiang population in China, is currently available. Hence, the current study investigated the adaptability of facial soft tissue to the underlying hard tissue among young adults of Han population in Xinjiang, China; the analysis was performed on the basis of gender, skeletal class, and body mass index (BMI). Measurements were obtained from the lateral cephalometric radiographs of 256 adults aged 18-26 years old. Differences in soft tissue thickness were observed between genders and among skeletal classes. With regard to gender, significant differences in soft tissue thickness were found at rhinion, glabella, subnasale, stomion, labrale superius, pogonion, and gnathion among different BMI groups. Thus, nutritional status should be considered when reconstructing an individual's facial profile. Results showed that the thinnest and thickest craniofacial soft tissues existed in rhinion and lip regions, respectively. Overall, this research provides valuable data for forensic facial reconstruction and identification of young adults in Xinjiang, China. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  17. Soft tissue sarcoma - Compliance with guidelines

    NARCIS (Netherlands)

    Nijhuis, PHA; Schaapveld, M; Otter, R; Hoekstra, HJ

    2001-01-01

    BACKGROUND. Because soft tissue sarcomas (STS) are rare, guidelines for the diagnosis and treatment of patients with STS were developed. Because the diagnostic management is essential for definitive treatment, adherence to these guidelines is important. METHODS. Primary STS registered by the

  18. Development of computer-aided auto-ranging technique for a computed radiography system

    International Nuclear Information System (INIS)

    Ishida, M.; Shimura, K.; Nakajima, N.; Kato, H.

    1988-01-01

    For a computed radiography system, the authors developed a computer-aided autoranging technique in which the clinically useful image data are automatically mapped to the available display range. The preread image data are inspected to determine the location of collimation. A histogram of the pixels inside the collimation is evaluated regarding characteristic values such as maxima and minima, and then the optimal density and contrast are derived for the display image. The effect of the autoranging technique was investigated at several hospitals in Japan. The average rate of films lost due to undesirable density or contrast was about 0.5%

  19. Hard and soft tissue correlations in facial profiles: a canonical correlation study

    Directory of Open Access Journals (Sweden)

    Shamlan MA

    2015-01-01

    Full Text Available Manal A Shamlan,1 Abdullah M Aldrees2 1Faculty of Dentistry, King Abdulaziz University, Jeddah, 2Division of Orthodontics, Department of Pediatric Dentistry and Orthodontics, College of Dentistry, King Saud University, Riyadh, Saudi Arabia Background: The purpose of this study was to analyze the relationship between facial hard and soft tissues in normal Saudi individuals by studying the canonical correlation between specific hard tissue landmarks and their corresponding soft tissue landmarks. Methods: A retrospective, cross-sectional study was designed, with a sample size of 60 Saudi adults (30 males and 30 females who had a class I skeletal and dental relationship and normal occlusion. Lateral cephalometric radiographs of the study sample were investigated using a series of 29 linear and angular measurements of hard and soft tissue features. The measurements were calculated electronically using Dolphin® software, and the data were analyzed using canonical correlation. Results: Eighty-four percent of the variation in the soft tissue was explained by the variation in hard tissue. Conclusion: The position of the upper and lower incisors and inclination of the lower incisors influence upper lip length and lower lip position. The inclination of the upper incisors is associated with lower lip length. Keywords: facial profile, hard tissue, soft tissue, canonical correlation

  20. Rheumatoid arthritis of the craniocervical region: assessment and characterization of inflammatory soft tissue proliferations with unenhanced and contrast-enhanced CT

    Energy Technology Data Exchange (ETDEWEB)

    Czerny, C.; Grampp, S.; Henk, C.B. [University Hospital Vienna (Austria). Dept. of Radiology; Neuhold, A. [Institute for Diagnostic Imaging, Hospital Rudolfinerhaus, Vienna (Austria); Stiskal, M. [Institute for Diagnostic Imaging, Hospital Lainz, Vienna (Austria); Smolen, J. [Department of Rheumatology, University Hospital Vienna (Austria)

    2000-09-01

    The aim of this study was to depict and characterize inflammatory soft tissue proliferations caused by rheumatoid arthritis (RA) in the craniocervical region by unenhanced and contrast-enhanced CT. Computed tomography of the craniocervical region was performed in 35 patients in the axial plane before and after the i. v. administration of contrast material. According to the densities and contrast enhancement of the inflammatory soft tissue proliferations, four groups were classified. Ancillary findings, such as a compression of the dural sac or spinal cord, erosions of the bony structures, and atlantoaxial subluxation, were also evaluated. Inflammatory soft tissue proliferations were depicted in 28 of 35 patients and could be differentiated by unenhanced and contrast-enhanced CT according to the above defined criteria: effusion in 6 patients (17 %); hypervascular pannus in 8 (23 %); hypovascular pannus in 5 (14 %); and fibrous tissue in 9 patients (26 %). A compression of the dural sac was seen in 11 (31 %) patients; 3 of these had neurological symptoms. Erosions of the odontoid process were found in 20 (57 %) patients; 16 (80 %) of these also showed erosions of the atlas. Atlantoaxial subluxation was seen in 11 (31 %) patients. Inflammatory soft tissue proliferations in the craniocervical region caused by RA can be reliably demonstrated and classified by unenhanced and contrast-enhanced CT, which can differentiate between joint effusion and various forms of pannus and depict ancillary findings. Computed tomography is an alternative method for patients unable to undergo an MRI examination. (orig.)

  1. Rheumatoid arthritis of the craniocervical region: assessment and characterization of inflammatory soft tissue proliferations with unenhanced and contrast-enhanced CT

    International Nuclear Information System (INIS)

    Czerny, C.; Grampp, S.; Henk, C.B.; Stiskal, M.; Smolen, J.

    2000-01-01

    The aim of this study was to depict and characterize inflammatory soft tissue proliferations caused by rheumatoid arthritis (RA) in the craniocervical region by unenhanced and contrast-enhanced CT. Computed tomography of the craniocervical region was performed in 35 patients in the axial plane before and after the i. v. administration of contrast material. According to the densities and contrast enhancement of the inflammatory soft tissue proliferations, four groups were classified. Ancillary findings, such as a compression of the dural sac or spinal cord, erosions of the bony structures, and atlantoaxial subluxation, were also evaluated. Inflammatory soft tissue proliferations were depicted in 28 of 35 patients and could be differentiated by unenhanced and contrast-enhanced CT according to the above defined criteria: effusion in 6 patients (17 %); hypervascular pannus in 8 (23 %); hypovascular pannus in 5 (14 %); and fibrous tissue in 9 patients (26 %). A compression of the dural sac was seen in 11 (31 %) patients; 3 of these had neurological symptoms. Erosions of the odontoid process were found in 20 (57 %) patients; 16 (80 %) of these also showed erosions of the atlas. Atlantoaxial subluxation was seen in 11 (31 %) patients. Inflammatory soft tissue proliferations in the craniocervical region caused by RA can be reliably demonstrated and classified by unenhanced and contrast-enhanced CT, which can differentiate between joint effusion and various forms of pannus and depict ancillary findings. Computed tomography is an alternative method for patients unable to undergo an MRI examination. (orig.)

  2. Finite Element Methods for real-time Haptic Feedback of Soft-Tissue Models in Virtual Reality Simulators

    Science.gov (United States)

    Frank, Andreas O.; Twombly, I. Alexander; Barth, Timothy J.; Smith, Jeffrey D.; Dalton, Bonnie P. (Technical Monitor)

    2001-01-01

    We have applied the linear elastic finite element method to compute haptic force feedback and domain deformations of soft tissue models for use in virtual reality simulators. Our results show that, for virtual object models of high-resolution 3D data (>10,000 nodes), haptic real time computations (>500 Hz) are not currently possible using traditional methods. Current research efforts are focused in the following areas: 1) efficient implementation of fully adaptive multi-resolution methods and 2) multi-resolution methods with specialized basis functions to capture the singularity at the haptic interface (point loading). To achieve real time computations, we propose parallel processing of a Jacobi preconditioned conjugate gradient method applied to a reduced system of equations resulting from surface domain decomposition. This can effectively be achieved using reconfigurable computing systems such as field programmable gate arrays (FPGA), thereby providing a flexible solution that allows for new FPGA implementations as improved algorithms become available. The resulting soft tissue simulation system would meet NASA Virtual Glovebox requirements and, at the same time, provide a generalized simulation engine for any immersive environment application, such as biomedical/surgical procedures or interactive scientific applications.

  3. Imaging suspected cervical spine injury: Plain radiography or computed tomography? Systematic review

    Energy Technology Data Exchange (ETDEWEB)

    Cain, Gavin [Diagnostic Radiographer, Colchester Hospital University NHS Foundation Trust, Colchester General Hospital, Turner Road, Colchester, CO4 5JL Essex (United Kingdom)], E-mail: gavincain8@hotmail.com; Shepherdson, Jane; Elliott, Vicki; Svensson, Jon [Faculty of Health and Social Care, Anglia Ruskin University, East Road, Cambridge, CB1 9PT Cambridgeshire (United Kingdom); Brennan, Patrick [UCD School of Medicine and Medical Sciences, Health Science Building, Belfield, Dublin 4 (Ireland)

    2010-02-15

    Aim: (1) to establish which modality offers the greatest accuracy in the detection of cervical spine injury (CSI) Following trauma: plain radiography or computed tomography (CT), and (2) make an evidence-based recommendation for the initial imaging modality of choice. Method: A systematic literature review was performed to identify primary research studies which compare the diagnostic accuracy of plain radiography and CT with the results of a reference standard in the detection of CSI. A search of MEDLINE, EMBASE, CINAHL, Science Direct and Pubmed Central databases was conducted. Results: Ten studies were identified. Critical appraisal identified limitations among all studies. There was heterogeneity in the sensitivity estimates for plain radiography, whereas estimates for CT were consistently high. Examination of the reported sensitivities shows that CT outperforms plain radiography in the detection of CSI. Conclusion: CT is superior to plain radiography in the detection of CSI. However, the optimal imaging strategy depends on the patients' relative risk of injury. If at high-risk cervical CT is indicated. If at low-risk the increased cost and radiation exposure mean that screening CT may not be warranted, good-quality plain radiographs are sufficient.

  4. Reliability of various skeletal indicators in assessing vertical facial soft tissue pattern

    International Nuclear Information System (INIS)

    Ahmed, M.; Shaikh, A.; Fida, M.

    2016-01-01

    Background: Angle paradigm has ruled the orthodontic diagnosis and treatment planning for past several decades, but the recent introduction of the soft tissue paradigm has significantly changed the dynamics of orthodontic practice. This study was designed to identify skeletal analyses that best correlates with the parameters use to assess facial soft tissue profile that may lead to an accurate diagnosis and efficient treatment plan. Methods: A total of 192 subjects (96 males and 96 females; mean age 22.95±4.75 years) were included in the study. The total sample was distributed into three equal groups (i.e., long, normal and short face) on the basis of soft tissue vertical pattern. Pre-treatment lateral cephalograms were used to assess various vertical linear and angular parameters. Various skeletal analyses and soft tissue parameters were correlated using the Pearson correlation in different vertical groups, separately for males and females. Results: In males, a weak positive correlation (r=0.485) was found between skeletal anterior facial height ratio (Sk. LAFH/TAFH) and soft tissue anterior facial height ratio (LAFH/TAFH), whereas in females maxillary-mandibular plane angle (MMA) showed a weak positive correlation (r=0.300). In the long face group, a positive but a weak correlation (r=0.349) was present between cranial base angle (SN-GoGn) and LAFH/TAFH. Conclusions: Skeletal analyses (MMA, Sk. LAFH/TAFH) significantly correlated to soft tissue parameters. Males and long faced individuals showed a higher correlation between skeletal and soft tissue parameters as compared to that of the females. (author)

  5. Diffusible iodine-based contrast-enhanced computed tomography (diceCT): an emerging tool for rapid, high-resolution, 3-D imaging of metazoan soft tissues.

    Science.gov (United States)

    Gignac, Paul M; Kley, Nathan J; Clarke, Julia A; Colbert, Matthew W; Morhardt, Ashley C; Cerio, Donald; Cost, Ian N; Cox, Philip G; Daza, Juan D; Early, Catherine M; Echols, M Scott; Henkelman, R Mark; Herdina, A Nele; Holliday, Casey M; Li, Zhiheng; Mahlow, Kristin; Merchant, Samer; Müller, Johannes; Orsbon, Courtney P; Paluh, Daniel J; Thies, Monte L; Tsai, Henry P; Witmer, Lawrence M

    2016-06-01

    Morphologists have historically had to rely on destructive procedures to visualize the three-dimensional (3-D) anatomy of animals. More recently, however, non-destructive techniques have come to the forefront. These include X-ray computed tomography (CT), which has been used most commonly to examine the mineralized, hard-tissue anatomy of living and fossil metazoans. One relatively new and potentially transformative aspect of current CT-based research is the use of chemical agents to render visible, and differentiate between, soft-tissue structures in X-ray images. Specifically, iodine has emerged as one of the most widely used of these contrast agents among animal morphologists due to its ease of handling, cost effectiveness, and differential affinities for major types of soft tissues. The rapid adoption of iodine-based contrast agents has resulted in a proliferation of distinct specimen preparations and scanning parameter choices, as well as an increasing variety of imaging hardware and software preferences. Here we provide a critical review of the recent contributions to iodine-based, contrast-enhanced CT research to enable researchers just beginning to employ contrast enhancement to make sense of this complex new landscape of methodologies. We provide a detailed summary of recent case studies, assess factors that govern success at each step of the specimen storage, preparation, and imaging processes, and make recommendations for standardizing both techniques and reporting practices. Finally, we discuss potential cutting-edge applications of diffusible iodine-based contrast-enhanced computed tomography (diceCT) and the issues that must still be overcome to facilitate the broader adoption of diceCT going forward. © 2016 The Authors. Journal of Anatomy published by John Wiley & Sons Ltd on behalf of Anatomical Society.

  6. Measuring device for soft X-rays

    International Nuclear Information System (INIS)

    Dissing, E.

    1978-09-01

    An instrument for the measurement of the absorbed energy per unit area of diagnostic X-rays in soft human tissue was developed. The instrument is intended for dosimetry applications in the field of dental and small skeleton radiography and for mammography. The detector assembly consists of a Polyvinyltoluene scintillator 2.54 diametre x 5.08 cm CsSb semitransparent head-on vacuum phototube. Polyvinyltoluene being a pure hydrocarbon may be considered a good representative material of human soft tissue concerning the absorption of X-rays. In the photon energy range of interest, 5 - 40 keV, the mass energy absorption coefficient for muscle tissue and for PVT differ about a factor 2 due to the considerable content of Oxygen in muscle tissue. This is to some extend reflected in the photon energy response characteristic for the instrument. For human adipose, the characteristic is practically flat from 5- 40 keV. The instrument is integrating the absorbed power per unit area and the digital display shows Joules/m 2 . The range for the instrument is from 000.1 μJ/m 2 to 19.99 J/m 2 (absorbed energy in 5 cm tissue). (author)

  7. Clinical significance of abnormal nonosseous soft tissue uptake of bone tracer

    International Nuclear Information System (INIS)

    Zhu Bao; Shang Yukun; Li Jiannan; Bai Jing; Cai Liang

    2006-01-01

    Objective: To evaluate the clinical significance of abnormal soft tissue uptake of bone tracer. Methods: Thirty patients with abnormal soft tissue uptake of bone tracer on 99 Tc m -methylene diphosphonic acid (MDP) skeletal imaging were analyzed. Radioactivity of soft tissue accumulated equal to or greater than the ribs were considered as abnormal. The result was compared with pathology, MRI, CT, X-ray, ultrasound, findings for evaluating its clinical significance. Results: In 7 patients with diffuse liver uptake of 99 Tc m -MDP, 6 were massive and 1 nodular liver cancer. In 2 patients with local liver uptake, one was metastatic and the other primary liver cancer. In 5 local lung uptake cases 4 were primary lung cancer and one metastatic. In 5 cases with colonic uptake 1 was schistosomiasis while the other 4 unexplainable. Subcutaneous tissue uptake was observed in 4 patients, symmetrical uptake in 2 patients with metastatic calcification microfoci in multiple myeloma, unsymmetrical uptake in 2 patients with hemangioma and abscess. Pleural uptake in 3 patients all was metastatic cancer. Abdominal uptake in 3 patients was omentum, paravertebral soft tissue metastasis and unknown cause. Breast uptake in one patient was due to breast cancer. Conclusions: There are many causes resulting in abnormal nonosseous soft tissue uptake of 99 Tc m -MDP. The final diagnosis should correlate with clinical data and other examinations. (authors)

  8. Lung nodule detection by microdose CT versus chest radiography (standard and dual-energy subtracted).

    Science.gov (United States)

    Ebner, Lukas; Bütikofer, Yanik; Ott, Daniel; Huber, Adrian; Landau, Julia; Roos, Justus E; Heverhagen, Johannes T; Christe, Andreas

    2015-04-01

    The purpose of this study was to investigate the feasibility of microdose CT using a comparable dose as for conventional chest radiographs in two planes including dual-energy subtraction for lung nodule assessment. We investigated 65 chest phantoms with 141 lung nodules, using an anthropomorphic chest phantom with artificial lung nodules. Microdose CT parameters were 80 kV and 6 mAs, with pitch of 2.2. Iterative reconstruction algorithms and an integrated circuit detector system (Stellar, Siemens Healthcare) were applied for maximum dose reduction. Maximum intensity projections (MIPs) were reconstructed. Chest radiographs were acquired in two projections with bone suppression. Four blinded radiologists interpreted the images in random order. A soft-tissue CT kernel (I30f) delivered better sensitivities in a pilot study than a hard kernel (I70f), with respective mean (SD) sensitivities of 91.1%±2.2% versus 85.6%±5.6% (p=0.041). Nodule size was measured accurately for all kernels. Mean clustered nodule sensitivity with chest radiography was 45.7%±8.1% (with bone suppression, 46.1%±8%; p=0.94); for microdose CT, nodule sensitivity was 83.6%±9% without MIP (with additional MIP, 92.5%±6%; pmicrodose CT for readers 1, 2, 3, and 4 were 84.3%, 90.7%, 68.6%, and 45.0%, respectively. Sensitivities with chest radiography for readers 1, 2, 3, and 4 were 42.9%, 58.6%, 36.4%, and 90.7%, respectively. In the per-phantom analysis, respective sensitivities of microdose CT versus chest radiography were 96.2% and 75% (pmicrodose CT, the applied dose was 0.1323 mSv. Microdose CT is better than the combination of chest radiography and dual-energy subtraction for the detection of solid nodules between 5 and 12 mm at a lower dose level of 0.13 mSv. Soft-tissue kernels allow better sensitivities. These preliminary results indicate that microdose CT has the potential to replace conventional chest radiography for lung nodule detection.

  9. Progress in digital radiography

    International Nuclear Information System (INIS)

    Cappelle, A.

    2016-01-01

    Because of its practical aspect digital radiography is more and more used in the industrial sector. There are 2 kinds of digital radiography. First, the 'computed radiography' that uses a photon-stimulated screen, and after radiation exposure this screen must be read by an analyser to get a digit image. The second type is the 'direct radiography' that allows one to get a digit radiograph of the object directly. Digital radiography uses the same radioactive nuclides as radiography with silver films: cobalt, iridium or selenium. The spatial resolution of digital radiography is less good than with classical silver film radiography but digital radiography offers a better visual contrast. (A.C.)

  10. Interobserver agreement and performance score comparison in quality control using a breast phantom: screen-film mammography vs computed radiography

    International Nuclear Information System (INIS)

    Shimamoto, Kazuhiro; Ikeda, Mitsuru; Satake, Hiroko; Ishigaki, Satoko; Sawaki, Akiko; Ishigaki, Takeo

    2002-01-01

    Our objective was to evaluate interobserver agreement and to compare the performance score in quality control of screen-film mammography and computed radiography (CR) using a breast phantom. Eleven radiologists interpreted a breast phantom image (CIRS model X) by four viewing methods: (a) original screen-film; (b) soft-copy reading of the digitized film image; (c) hard-copy reading of CR using an imaging plate; and (d) soft-copy reading of CR. For the soft-copy reading, a 17-in. CRT monitor (1024 x 1536 x 8 bits) was used. The phantom image was evaluated using a scoring system outlined in the instruction manual, and observers judged each object using a three-point rating scale: (a) clearly seen; (b) barely seen; and (c) not seen. For statistical analysis, the kappa statistic was employed. For ''mass'' depiction, interobserver agreement using CR was significantly lower than when using screen-film (p<0.05). There was no significant difference in the kappa value for detecting ''microcalcification''; however, the performance score of ''microcalcification'' on CR hard-copy was significantly lower than on the other three viewing methods (p<0.05). Viewing methods (film or CR, soft-copy or hard-copy) could affect how the phantom image is judged. Paying special attention to viewing conditions is recommended for quality control of CR mammograms. (orig.)

  11. Emergency repair of upper extremity large soft tissue and vascular injuries with flow-through anterolateral thigh free flaps.

    Science.gov (United States)

    Zhan, Yi; Fu, Guo; Zhou, Xiang; He, Bo; Yan, Li-Wei; Zhu, Qing-Tang; Gu, Li-Qiang; Liu, Xiao-Lin; Qi, Jian

    2017-12-01

    Complex extremity trauma commonly involves both soft tissue and vascular injuries. Traditional two-stage surgical repair may delay rehabilitation and functional recovery, as well as increase the risk of infections. We report a single-stage reconstructive surgical method that repairs soft tissue defects and vascular injuries with flow-through free flaps to improve functional outcomes. Between March 2010 and December 2016 in our hospital, 5 patients with severe upper extremity trauma received single-stage reconstructive surgery, in which a flow-through anterolateral thigh free flap was applied to repair soft tissue defects and vascular injuries simultaneously. Cases of injured artery were reconstructed with the distal trunk of the descending branch of the lateral circumflex femoral artery. A segment of adjacent vein was used if there was a second artery injury. Patients were followed to evaluate their functional recoveries, and received computed tomography angiography examinations to assess peripheral circulation. Two patients had post-operative thumb necrosis; one required amputation, and the other was healed after debridement and abdominal pedicle flap repair. The other 3 patients had no major complications (infection, necrosis) to the recipient or donor sites after surgery. All the patients had achieved satisfactory functional recovery by the end of the follow-up period. Computed tomography angiography showed adequate circulation in the peripheral vessels. The success of these cases shows that one-step reconstructive surgery with flow-through anterolateral thigh free flaps can be a safe and effective treatment option for patients with complex upper extremity trauma with soft tissue defects and vascular injuries. Copyright © 2017. Published by Elsevier Ltd.

  12. Radiology and pathology of malignant fibrous histiocytomas of the soft tissues a report of ten cases

    International Nuclear Information System (INIS)

    Fischer, H.J.; Lois, J.F.; Gomes, A.S.; Mirra, J.M.; Deutsch, L.S.

    1985-01-01

    Malignant fibrous histiocytomas (MFH) are believed to originate from histiocytes and are composed of malignant cells with spindle or round shapes. We evaluated ten MFH of the soft tissues by plain roentgenograms, computed tomography (CT), and angiography and subdivided them into four grades of anaplasia and five predominant histologic variants. The variants of MFH demonstrated different vascular patterns. The extension of the lesions could be determinded by CT and angiography. CT is the method of choice in the assessment of size and extent of MFH of the soft tissues. When intra-arterial chemotherapy is indicated the angiograms obtained at each catheter placement may substitute CT in follow-up studies obviating additional diagnostic procedures. (orig.)

  13. Radiology and pathology of malignant fibrous histiocytomas of the soft tissues; a report of ten cases

    Energy Technology Data Exchange (ETDEWEB)

    Fischer, H.J.; Lois, J.F.; Gomes, A.S.; Mirra, J.M.; Deutsch, L.S.

    1985-03-01

    Malignant fibrous histiocytomas (MFH) are believed to originate from histiocytes and are composed of malignant cells with spindle or round shapes. We evaluated ten MFH of the soft tissues by plain roentgenograms, computed tomography (CT), and angiography and subdivided them into four grades of anaplasia and five predominant histologic variants. The variants of MFH demonstrated different vascular patterns. The extension of the lesions could be determinded by CT and angiography. CT is the method of choice in the assessment of size and extent of MFH of the soft tissues. When intra-arterial chemotherapy is indicated the angiograms obtained at each catheter placement may substitute CT in follow-up studies obviating additional diagnostic procedures.

  14. Hybrid soft computing approaches research and applications

    CERN Document Server

    Dutta, Paramartha; Chakraborty, Susanta

    2016-01-01

    The book provides a platform for dealing with the flaws and failings of the soft computing paradigm through different manifestations. The different chapters highlight the necessity of the hybrid soft computing methodology in general with emphasis on several application perspectives in particular. Typical examples include (a) Study of Economic Load Dispatch by Various Hybrid Optimization Techniques, (b) An Application of Color Magnetic Resonance Brain Image Segmentation by ParaOptiMUSIG activation Function, (c) Hybrid Rough-PSO Approach in Remote Sensing Imagery Analysis,  (d) A Study and Analysis of Hybrid Intelligent Techniques for Breast Cancer Detection using Breast Thermograms, and (e) Hybridization of 2D-3D Images for Human Face Recognition. The elaborate findings of the chapters enhance the exhibition of the hybrid soft computing paradigm in the field of intelligent computing.

  15. Establishing the soft and hard tissue area centers (centroids) for the skull and introducing a newnon-anatomical cephalometric line

    International Nuclear Information System (INIS)

    AlBalkhi, Khalid M; AlShahrani, Ibrahim; AlMadi, Abdulaziz

    2008-01-01

    The purpose of this study was to demonstrate how to establish the area center (centroid) of both the soft and hard tissues of the outline of the lateral cephalometric skull image, and to introduce the concept of a new non-anatomical centroid line. Lateral cephalometric radiographs, size 12 x 14 inch, of fifty seven adult subjects were selected based on their pleasant, balanced profile, Class I skeletal and dental relationship and no major dental malocclusion or malrelationship. The area centers (centroids) of both soft and hard tissue skull were practically established using a customized software computer program called the m -file . Connecting the two centers introduced the concept of a new non-anatomical soft and hard centroids line. (author)

  16. Magnetic resonance imaging of peripheral soft tissue hemangiomas

    Energy Technology Data Exchange (ETDEWEB)

    Nelson, M C; Stull, M A; Patt, R H; Freedman, M T [Georgetown Univ., Washington, DC (USA). Dept. of Radiology; Teitelbaum, G P [Georgetown Univ., Washington, DC (USA). Dept. of Radiology University of Southern California, Los Angeles (USA). Dept. of Radiology; Lack, E E [Georgetown Univ., Washington, DC (USA). Dept. of Pathology; Bogumill, G P [Georgetown Univ., Washington, DC (USA). Dept. of Orthopedic Surgery

    1990-10-01

    Ten patients with soft tissue hemangiomas outside the central nervous system were studied with MR imaging. Eight patients were studied at 1.5 Tesla (T) with T{sub 1}-weighted and triple echo T{sub 2}-weighted sequences. Two additional patients were imaged on a 0.5-T system. The MR images were correlated with images from other modalities. It was found that prolonged T{sub 2}-weighted imaging together with standard spin echo T{sub 1} and T{sub 2} pulse sequences is a good substitute for contrast-enhanced CT and arteriographic evaluation of soft tissue hemangiomas. (orig./DG).

  17. Hybrid Carbon-Based Scaffolds for Applications in Soft Tissue Reconstruction

    Science.gov (United States)

    Lafdi, Khalid; Joseph, Robert M.; Tsonis, Panagiotis A.

    2012-01-01

    Current biomedical scaffolds utilized in surgery to repair soft tissues commonly fail to meet the optimal combination of biomechanical and tissue regenerative properties. Carbon is a scaffold alternative that potentially optimizes the balance between mechanical strength, durability, and function as a cell and biologics delivery vehicle that is necessary to restore tissue function while promoting tissue repair. The goals of this study were to investigate the feasibility of fabricating hybrid fibrous carbon scaffolds modified with biopolymer, polycaprolactone and to analyze their mechanical properties and ability to support cell growth and proliferation. Environmental scanning electron microscopy, micro-computed tomography, and cell adhesion and cell proliferation studies were utilized to test scaffold suitability as a cell delivery vehicle. Mechanical properties were tested to examine load failure and elastic modulus. Results were compared to an acellular dermal matrix scaffold control (GraftJacket® [GJ] Matrix), selected for its common use in surgery for the repair of soft tissues. Results indicated that carbon scaffolds exhibited similar mechanical maximums and capacity to support fibroblast adhesion and proliferation in comparison with GJ. Fibroblast adhesion and proliferation was collinear with carbon fiber orientation in regions of sparsely distributed fibers and occurred in clusters in regions of higher fiber density and low porosity. Overall, fibroblast adhesion and proliferation was greatest in lower porosity carbon scaffolds with highly aligned fibers. Stepwise multivariate regression showed that the variability in maximum load of carbon scaffolds and controls were dependent on unique and separate sets of parameters. These finding suggested that there were significant differences in the functional implications of scaffold design and material properties between carbon and dermis derived scaffolds that affect scaffold utility as a tissue replacement

  18. In vivo evaluation of defined polished titanium surfaces to prevent soft tissue adhesion.

    Science.gov (United States)

    Hayes, Jessica S; Welton, Joanne L; Wieling, Ronald; Richards, R Geoff

    2012-04-01

    Soft tissue-implant adhesion is often required for implant integration into the body; however, in some situations, the tissue is required to glide freely over an implant. In the case of distal radius fracture treatment, current literature describes how titanium and its alloys tend to lead to more intra-tendon inflammatory reactions compared with stainless steel. This leads to tendon-implant adhesion and damage possibly causing limited palmar flexion and even tendon rupture. The goal of this study was to analyze the effect of different surface polishings of titanium and titanium molybdenum implants on soft tissue reactions in vivo, with the aim to prevent direct soft tissue adhesion. Using a nonfracture model, to allow for study of the soft-tissue-implant surface interactions only, six surface variants of the same plate design were implanted onto the tibia of 24 New Zealand white rabbits and left in situ for 12 weeks. Results indicate that paste polished commercially pure titanium and titanium molybdenum alloy had the least soft tissue adhesion, with the concomitant development of a soft tissue capsule. Surface topography did not appear influence the thickness of the connective tissue surrounding the plate. Therefore, suitable surface polishing could be applied to plates for clinical use, where free gliding of tissues is required. Copyright © 2012 Wiley Periodicals, Inc.

  19. Analyze image quality and comparative study between conventional and computed radiography applied to the inspection of alloys

    International Nuclear Information System (INIS)

    Machado, Alessandra S.; Oliveira, Davi F.; Silva, Aline S.S.; Nascimento, Joseilson R.; Lopes, Ricardo T.

    2011-01-01

    Piping system design takes into account relevant factors such as: internal coating, dimensioning, vibration system, adequate supports and principally, piping material. Cost is a decisive factor in the phase of material selection. The non-destructive testing method most commonly employed in industry to analyze the structure of an object is radiographic testing. Computed radiography (CR) is a quicker and much more efficient alternative to conventional radiography but, although CR presents numerous advantages, testing procedures are still largely based on trial and error, due to the lack of a consecrated methodology to choose parameters as it exists for conventional radiography. Notwithstanding, this paper presents a study that uses the technique of computed radiography to analyze metal alloys. These metal alloys are used as internal pipe coating aiming to protect against corrosion and cracks. This study seeks to evaluate parameters such as basic spatial resolution, Normalized Signal-to-Noise Ratio (SNRN), contrast, intensity and also to compare conventional radiography with CR. (author)

  20. Complex system modelling and control through intelligent soft computations

    CERN Document Server

    Azar, Ahmad

    2015-01-01

    The book offers a snapshot of the theories and applications of soft computing in the area of complex systems modeling and control. It presents the most important findings discussed during the 5th International Conference on Modelling, Identification and Control, held in Cairo, from August 31-September 2, 2013. The book consists of twenty-nine selected contributions, which have been thoroughly reviewed and extended before their inclusion in the volume. The different chapters, written by active researchers in the field, report on both current theories and important applications of soft-computing. Besides providing the readers with soft-computing fundamentals, and soft-computing based inductive methodologies/algorithms, the book also discusses key industrial soft-computing applications, as well as multidisciplinary solutions developed for a variety of purposes, like windup control, waste management, security issues, biomedical applications and many others. It is a perfect reference guide for graduate students, r...

  1. Treatment of oral soft tissues benign tumors using laser

    Science.gov (United States)

    Crisan, Bogdan; Baciut, Mihaela; Crisan, Liana; Bran, Simion; Rotar, Horatiu; Dinu, Cristian; Moldovan, Iuliu; Baciut, Grigore

    2014-01-01

    The present study aimed to assess the efficacy and indications of surgical laser therapy in the treatment of oral soft tissues benign tumors compared to classic surgery. A controlled clinical study was conducted in a group of 93 patients presenting various forms of oral soft tissues benign tumors. These patients were examined pre-and postoperatively and the oral benign tumors were measured linearly and photographed. The surgery of laser-assisted biopsy excision of oral benign tumors was carried out using a diode laser device of 980 nm. In patients who received surgical laser treatment, therapeutic doses of laser to biostimulate the operated area were administered on the first day after the surgery. The interventions of conventional excision of oral soft tissues benign tumors consisted in removing them using scalpel. In patients who have received therapeutic doses of laser for biostimulation of the operated area, a faster healing of wound surfaces and tumor bed was observed during the first days after surgery. Two weeks after the surgical treatment, good healing without scarring or discomfort in the area of excision was documented. Surgical treatment of oral soft tissues benign tumors with laser assisted postoperative therapy confirms the benefits of this surgical procedure. A faster healing process of the excision area due to laser biostimulation of low intensity has been observed in patients with surgical laser assisted treatment in the postoperative period.

  2. Usefulness of 2D fusion of postmortem CT and antemortem chest radiography studies for human identification.

    Science.gov (United States)

    Shinkawa, Norihiro; Hirai, Toshinori; Nishii, Ryuichi; Yukawa, Nobuhiro

    2017-06-01

    To determine the feasibility of human identification through the two-dimensional (2D) fusion of postmortem computed tomography (PMCT) and antemortem chest radiography. The study population consisted of 15 subjects who had undergone chest radiography studies more than 12 months before death. Fused images in which a chest radiograph was fused with a PMCT image were obtained for those subjects using a workstation, and the minimum distance gaps between corresponding anatomical landmarks (located at soft tissue and bone sites) in the images obtained with the two modalities were calculated. For each fused image, the mean of all these minimum distance gaps was recorded as the mean distance gap (MDG). For each subject, the MDG obtained for the same-subject fused image (i.e., where both of the images that were fused derived from that subject) was compared with the MDGs for different-subject fused images (i.e., where only one of the images that were fused derived from that subject; the other image derived from a different subject) in order to determine whether same-subject fused images can be reliably distinguished from different-subject fused images. The MDGs of the same-subject fused images were found to be significantly smaller than the MDGs of the different-subject fused images (p chest radiography and postmortem CT images may assist in human identification.

  3. Checklist and scoring system for the assessment of soft tissue preservation in CT examinations of human mummies. Application to the Tyrolean Iceman

    Energy Technology Data Exchange (ETDEWEB)

    Panzer, Stephanie [Trauma Center Murnau (Germany). Dept. of Radiology; Trauma Center Murnau and Paracelsus Medical Univ. Salzburg, Murnau (Germany). Inst. of Biomechanics; Pernter, Patrizia [Central Hospital, Bozen (Italy). Dept. of Radiodiagnostics; Piombino-Mascali, Dario; Jankauskas, Rimantas [Vilnius Univ. (Lithuania). Dept. of Anatomy, Histology and Anthropology; Zesch, Stephanie; Rosendahl, Wilfried [Reiss-Engelhorn Museen, Mannheim (Germany). German Mummy Project; Hotz, Gerhard [Natural History Museum of Basel (Switzerland). Anthropology; Zink, Albert R. [EURAC-Institute for Mummies and the Iceman, Bolzano (Italy)

    2017-12-15

    Soft tissues make a skeleton into a mummy and they allow for a diagnosis beyond osteology. Following the approach of structured reporting in clinical radiology, a recently developed checklist was used to evaluate the soft tissue preservation status of the Tyrolean Iceman using computed tomography (CT). The purpose of this study was to apply the ''Checklist and Scoring System for the Assessment of Soft Tissue Preservation in CT Examinations of Human Mummies'' to the Tyrolean Iceman, and to compare the Iceman's soft tissue preservation score to the scores calculated for other mummies. A whole-body (CT) (SOMATOM Definition Flash, Siemens, Forchheim, Germany) consisting of five scans, performed in January 2013 in the Department of Radiodiagnostics, Central Hospital, Bolzano, was used (slice thickness 0.6mm; kilovolt ranging from80 to 140). For standardized evaluation the ''CT Checklist and Scoring System for the Assessment of Soft Tissue Preservation in Human Mummies'' was used. All checkpoints under category ''A. Soft Tissues of Head and Musculoskeletal System'' and more than half in category ''B. Organs and Organ Systems'' were observed. The scoring system accounted for a total score of 153 (out of 200). The comparison of the scores between the Iceman and three mummy collections from Vilnius, Lithuania, and Palermo, Sicily, as well as one Egyptian mummy resulted in overall higher soft tissue preservation scores for the Iceman. Application of the checklist allowed for standardized assessment and documentation of the Iceman's soft tissue preservation status. The scoring system allowed for a quantitative comparison between the Iceman and other mummies. The Iceman showed remarkable soft tissue preservation.

  4. Checklist and scoring system for the assessment of soft tissue preservation in CT examinations of human mummies. Application to the Tyrolean Iceman

    International Nuclear Information System (INIS)

    Panzer, Stephanie

    2017-01-01

    Soft tissues make a skeleton into a mummy and they allow for a diagnosis beyond osteology. Following the approach of structured reporting in clinical radiology, a recently developed checklist was used to evaluate the soft tissue preservation status of the Tyrolean Iceman using computed tomography (CT). The purpose of this study was to apply the ''Checklist and Scoring System for the Assessment of Soft Tissue Preservation in CT Examinations of Human Mummies'' to the Tyrolean Iceman, and to compare the Iceman's soft tissue preservation score to the scores calculated for other mummies. A whole-body (CT) (SOMATOM Definition Flash, Siemens, Forchheim, Germany) consisting of five scans, performed in January 2013 in the Department of Radiodiagnostics, Central Hospital, Bolzano, was used (slice thickness 0.6mm; kilovolt ranging from80 to 140). For standardized evaluation the ''CT Checklist and Scoring System for the Assessment of Soft Tissue Preservation in Human Mummies'' was used. All checkpoints under category ''A. Soft Tissues of Head and Musculoskeletal System'' and more than half in category ''B. Organs and Organ Systems'' were observed. The scoring system accounted for a total score of 153 (out of 200). The comparison of the scores between the Iceman and three mummy collections from Vilnius, Lithuania, and Palermo, Sicily, as well as one Egyptian mummy resulted in overall higher soft tissue preservation scores for the Iceman. Application of the checklist allowed for standardized assessment and documentation of the Iceman's soft tissue preservation status. The scoring system allowed for a quantitative comparison between the Iceman and other mummies. The Iceman showed remarkable soft tissue preservation.

  5. Facial soft-tissue fillers conference: assessing the state of the science.

    Science.gov (United States)

    Rohrich, Rod J; Hanke, C William; Busso, Mariano; Carruthers, Alastair; Carruthers, Jean; Fagien, Steven; Fitzgerald, Rebecca; Glogau, Richard; Greenberger, Phyllis E; Lorenc, Z Paul; Marmur, Ellen S; Monheit, Gary D; Pusic, Andrea; Rubin, Mark G; Rzany, Berthold; Sclafani, Anthony; Taylor, Susan; Weinkle, Susan; McGuire, Michael F; Pariser, David M; Casas, Laurie A; Collishaw, Karen J; Dailey, Roger A; Duffy, Stephen C; Edgar, Elizabeth Jan; Greenan, Barbara L; Haenlein, Kelly; Henrichs, Ronald A; Hume, Keith M; Lum, Flora; Nielsen, David R; Poulsen, Lisle; Shoaf, Lori; Schoaf, Lori; Seward, William; Begolka, Wendy Smith; Stanton, Robert G; Svedman, Katherine J; Thomas, J Regan; Sykes, Jonathan M; Wargo, Carol; Weiss, Robert A

    2011-04-01

    : The American Society of Plastic Surgeons and the American Academy of Dermatology, with the support of other sister societies, conducted the Facial Soft-Tissue Fillers: Assessing the State of the Science conference in December of 2009. The American Society of Plastic Surgeons and the American Academy of Dermatology established a panel of leading experts in the field of soft-tissue fillers-from researchers to clinicians-and other stakeholders for the conference to examine and discuss issues of patient safety, efficacy, and effectiveness in relation to the approved and off-label use of soft-tissue fillers, and other factors, including the training and level of experience of individuals administering fillers. This report represents the systematic literature review that examines comprehensively the available evidence and gaps in the evidence related to soft-tissue fillers, to inform and support the work of the state-of-the-science conference panel. This evidence-based medicine review will serve as the foundation for future evidence-based medicine reports in this growing field.

  6. Digital radiography

    International Nuclear Information System (INIS)

    Zani, M.L.

    2002-01-01

    X-ray radiography is a very common technique used to check the homogeneity of a material or the inside of a mechanical part. Generally the radiation that goes through the material to check, produced an image on a sensitized film. This method requires time because the film needs to be developed, digital radiography has no longer this inconvenient. In digital radiography the film is replaced by digital data and can be processed as any computer file. This new technique is promising but its main inconvenient is that today its resolution is not so good as that of film radiography. (A.C.)

  7. Advances in computed radiography systems and their physical imaging characteristics

    International Nuclear Information System (INIS)

    Cowen, A.R.; Davies, A.G.; Kengyelics, S.M.

    2007-01-01

    Radiological imaging is progressing towards an all-digital future, across the spectrum of medical imaging techniques. Computed radiography (CR) has provided a ready pathway from screen film to digital radiography and a convenient entry point to PACS. This review briefly revisits the principles of modern CR systems and their physical imaging characteristics. Wide dynamic range and digital image enhancement are well-established benefits of CR, which lend themselves to improved image presentation and reduced rates of repeat exposures. However, in its original form CR offered limited scope for reducing the radiation dose per radiographic exposure, compared with screen film. Recent innovations in CR, including the use of dual-sided image readout and channelled storage phosphor have eased these concerns. For example, introduction of these technologies has improved detective quantum efficiency (DQE) by approximately 50 and 100%, respectively, compared with standard CR. As a result CR currently affords greater scope for reducing patient dose, and provides a more substantive challenge to the new solid-state, flat-panel, digital radiography detectors

  8. Fuji computed radiography (FCR) for the diagnosis of spinal disorders

    Energy Technology Data Exchange (ETDEWEB)

    Kubo, Yoshichika; Waga, Shiro; Kojima, Tadashi

    1987-04-01

    Since April, 1985, we have, in co-operation with the Fuji Film Co., Ltd., used Fuji Computed Radiography (FCR) in the diagnosis of spinal disorders. FCR is a new computed radiographic system which uses an energy-storage phosphorus panel called an ''Imaging Plate'' as an image sensor. The ''Imaging Plate'' can be used to obtain radiographs in exactly the same way as the screen-film combination used in conventional radiography; X-rays are exposed on the ''Imaging Plate'' instead of X-ray film in the conventional fashion, and then the ''Imaging Plate'' is calculated. The processed digital data from the scans is transformed into a picture by means of digital-to-analogue conversion. The pictures are always clear and beautiful. Plain films of the spine taken by FCR are even clearer, even in the cervicothoracic region, where it is usually difficult to obtain clear cervicothoracic films in conventional radiography. We can obtain much precise information about the spinal posterior osteophytes and grafted bone, even when the patients are immobilized in a Halo apparatus. In myelography, the pictures are also clearer; we can see how the root or roots are compressed, how the dura and cord are involved in patients with cervical disc disease, and even the very narrow space between the cord and an intradural tumor. FCR is thus very useful in observing spinal disorders, either in plain films or myelography.

  9. Fuji computed radiography (FCR) for the diagnosis of spinal disorders

    International Nuclear Information System (INIS)

    Kubo, Yoshichika; Waga, Shiro; Kojima, Tadashi

    1987-01-01

    Since April, 1985, we have, in co-operation with the Fuji Film Co., Ltd., used Fuji Computed Radiography (FCR) in the diagnosis of spinal disorders. FCR is a new computed radiographic system which uses an energy-storage phosphorus panel called an ''Imaging Plate'' as an image sensor. The ''Imaging Plate'' can be used to obtain radiographs in exactly the same way as the screen-film combination used in conventional radiography; X-rays are exposed on the ''Imaging Plate'' instead of X-ray film in the conventional fashion, and then the ''Imaging Plate'' is calculated. The processed digital data from the scans is transformed into a picture by means of digital-to-analogue conversion. The pictures are always clear and beautiful. Plain films of the spine taken by FCR are even clearer, even in the cervicothoracic region, where it is usually difficult to obtain clear cervicothoracic films in conventional radiography. We can obtain much precise information about the spinal posterior osteophytes and grafted bone, even when the patients are immobilized in a Halo apparatus. In myelography, the pictures are also clearer; we can see how the root or roots are compressed, how the dura and cord are involved in patients with cervical disc disease, and even the very narrow space between the cord and an intradural tumor. FCR is thus very useful in observing spinal disorders, either in plain films or myelography. (author)

  10. Internal anatomy of the hornbill casque described by radiography, contrast radiography, and computed tomography.

    Science.gov (United States)

    Gamble, Kathryn C

    2007-03-01

    Hornbills are distinguished from most other avian taxa by the presence of a casque on the dorsal maxillary beak, which, in all but 1 of the 54 extant hornbill species, is described as essentially an air-filled cavity enclosed by minimal cancellous bone. The external casque has been described in detail, but little has been described about its internal anatomy and the communications between the casque and the paranasal sinuses. In this study, 10 intact casque and skull specimens of 7 hornbill species were collected opportunistically at necropsy. The anatomy of the casque and the skull for each of the specimens was examined by radiography, contrast radiography, and computed tomography. After imaging, 8 specimens were submitted for osteologic preparation to directly visualize the casque and the skull interior. Through this standardized review, the baseline anatomy of the internal casque was described, including identification of a novel casque sinus within the paranasal sinus system. These observations will assist clinicians in the diagnosis and treatment of diseases of the casque in hornbill species.

  11. MR imaging of uncommon soft tissue tumors in the foot: a pictorial essay

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Youn Joo; Chun, Kyung Ah; Kim, Jee Young; Sung, Mi Sook; Kim, Ki Tae [The Catholic University of Korea, Uijeongbu (Korea, Republic of)

    2007-06-15

    The large variety of masses occur in the foot. The foot is a comparatively rare site of soft tissue neoplasms. MRI has greatly improved the ability to detect and delineate soft tissue lesions and is now considered the gold-standard imaging technique in their investigation. Recently, we have encountered rare soft tissue tumors of the foot. The presented cases include benign masses such as granuloma annulare, angiomyoma, neural fibrolipoma, and giant cell tumor of tendon sheath, as well as malignant tumors such as melanoma, synovial sarcoma, rhabdomyosarcoma and extraskeletal myxoid chondrosarcoma. We wish to illustrate the MR findings of these uncommon soft tissue mors to aid in their diagnosis.

  12. [Update on soft tissue sarcomas].

    Science.gov (United States)

    Bui, Binh Nguyen; Tabrizi, Reza; Dagada, Corinne; Trufflandier, Nathalie; St ckle, Eberhard; Coindre, Jean-Michel

    2002-01-01

    Important refinements have taken place in the diagnosis of soft tissue sarcoma with extensive use of immuno-histochemistry. New entities have been described, while malignant histiocytofibroma, the most diagnosed sarcoma type during the last two decades, has been dismembered. As for prognosis, the new UICC classification is effectively more discriminating in the definition of prognostic groups; but the usefullness of new biological or genetic markers remains to be assessed. Several breakthrough have taken place in the last years in the treatment of soft tissue sarcoma. Isolated limb perfusion with TNF, hyperthermia and melphalan have proven its efficacy, and is now an alternative to preoperative chemotherapy and/or radiotherapy for limb sparing treatment of the primary tumor site or to amputation. For systemic treatments, novel cytostatic drugs have been shown to be active in sarcomas, including ecteinascidine (ET743) and Glivec (STI571). This last drug has been shown to be remarkably active in c-kit+ stromal sarcoma of the gastro-intestinal tract. It can hopefully regarded as an example for targeted therapies, which may come with a better understanding of the molecular mechanisms triggered by the fundamental, specific genetic alterations shown in sarcoma.

  13. Soft tissue thickness of face profile conditioning by dento-skeletal anomalies

    Directory of Open Access Journals (Sweden)

    Tanić Tatjana

    2011-01-01

    Full Text Available Introduction. Orthodontic treatment of dento-skeletal anomalies is generally based on the correction of teeth and jaws relationship, while it is expected that soft facial tissue spontaneously adapts to therapeutically achieved relationship and to accompany hard tissue changes. Objective. To establish facial soft tissue thickness conditioning by the presence of dento-skeletal anomalies. Methods. The study was performed at the Dental Clinic of Niš, and involved the analysis of cephalometric rendgenograms in 121 patients, aged 12-18 years, with no previous orthodontical treatment. According to dento-skeletal relationship between teeth and jaws the patients were divided into four groups; class I (control group, class II of division 1, class II of division 2 and class III. The standard analysis of dento-skeletal profile was done according to Steiner and soft tissue profile according to Burstone was done in all. Results. The patients of class II/1 had a significantly thinner upper lip (t=2.650; p<0.05 and thinner upper lip sulcus (t=1.999; p<0.05. The patients of class II/2 had a significantly thicker upper lip (t=2.912; p<0.01, while those of class III had a significantly thinner lower lip (t=3.900; p<0.001. Conclusion. The thickness of facial soft tissue considerably influences facial profile appearance in persons with a dento-skeletal anomaly. Not only do soft tissues adapt to the existing jaws relationship, but can also camouflage present anomalies.

  14. Correlation of the clinical and physical image quality in chest radiography for average adults with a computed radiography imaging system.

    Science.gov (United States)

    Moore, C S; Wood, T J; Beavis, A W; Saunderson, J R

    2013-07-01

    The purpose of this study was to examine the correlation between the quality of visually graded patient (clinical) chest images and a quantitative assessment of chest phantom (physical) images acquired with a computed radiography (CR) imaging system. The results of a previously published study, in which four experienced image evaluators graded computer-simulated postero-anterior chest images using a visual grading analysis scoring (VGAS) scheme, were used for the clinical image quality measurement. Contrast-to-noise ratio (CNR) and effective dose efficiency (eDE) were used as physical image quality metrics measured in a uniform chest phantom. Although optimal values of these physical metrics for chest radiography were not derived in this work, their correlation with VGAS in images acquired without an antiscatter grid across the diagnostic range of X-ray tube voltages was determined using Pearson's correlation coefficient. Clinical and physical image quality metrics increased with decreasing tube voltage. Statistically significant correlations between VGAS and CNR (R=0.87, pchest CR images acquired without an antiscatter grid. A statistically significant correlation has been found between the clinical and physical image quality in CR chest imaging. The results support the value of using CNR and eDE in the evaluation of quality in clinical thorax radiography.

  15. Soft computing integrating evolutionary, neural, and fuzzy systems

    CERN Document Server

    Tettamanzi, Andrea

    2001-01-01

    Soft computing encompasses various computational methodologies, which, unlike conventional algorithms, are tolerant of imprecision, uncertainty, and partial truth. Soft computing technologies offer adaptability as a characteristic feature and thus permit the tracking of a problem through a changing environment. Besides some recent developments in areas like rough sets and probabilistic networks, fuzzy logic, evolutionary algorithms, and artificial neural networks are core ingredients of soft computing, which are all bio-inspired and can easily be combined synergetically. This book presents a well-balanced integration of fuzzy logic, evolutionary computing, and neural information processing. The three constituents are introduced to the reader systematically and brought together in differentiated combinations step by step. The text was developed from courses given by the authors and offers numerous illustrations as

  16. Soft Tissue Tumor Immunohistochemistry Update: Illustrative Examples of Diagnostic Pearls to Avoid Pitfalls.

    Science.gov (United States)

    Wei, Shi; Henderson-Jackson, Evita; Qian, Xiaohua; Bui, Marilyn M

    2017-08-01

    - Current 2013 World Health Organization classification of tumors of soft tissue arranges these tumors into 12 groups according to their histogenesis. Tumor behavior is classified as benign, intermediate (locally aggressive), intermediate (rarely metastasizing), and malignant. In our practice, a general approach to reaching a definitive diagnosis of soft tissue tumors is to first evaluate clinicoradiologic, histomorphologic, and cytomorphologic features of the tumor to generate some pertinent differential diagnoses. These include the potential line of histogenesis and whether the tumor is benign or malignant, and low or high grade. Although molecular/genetic testing is increasingly finding its applications in characterizing soft tissue tumors, currently immunohistochemistry still not only plays an indispensable role in defining tumor histogenesis, but also serves as a surrogate for underlining molecular/genetic alterations. Objective- To provide an overview focusing on the current concepts in the classification and diagnosis of soft tissue tumors, incorporating immunohistochemistry. This article uses examples to discuss how to use the traditional and new immunohistochemical markers for the diagnosis of soft tissue tumors. Practical diagnostic pearls, summary tables, and figures are used to show how to avoid diagnostic pitfalls. - Data were obtained from pertinent peer-reviewed English-language literature and the authors' first-hand experience as bone and soft tissue pathologists. - -The ultimate goal for a pathologist is to render a specific diagnosis that provides diagnostic, prognostic, and therapeutic information to guide patient care. Immunohistochemistry is integral to the diagnosis and management of soft tissue tumors.

  17. Use of Artelon® Cosmetic in soft tissue augmentation in dentistry

    Directory of Open Access Journals (Sweden)

    Ko YK

    2011-06-01

    Full Text Available Youngkyung Ko, NamRyang Kim, Seojin Park, Jun-Beom ParkDepartment of Periodontics, Seoul St Mary's Hospital, The Catholic University of Korea, Seoul, KoreaBackground: Soft tissue augmentation is a widely used procedure in partially and fully edentulous patients to increase soft tissue volume. Polyurethanes have been used for scaffolds in a variety of implantable devices. Artelon® is a degradable polyurethane that has been manufactured as fibers, films, and porous scaffolds to be used for various purposes. In this review, the characteristics of Artelon are described, and its clinical applications in orthopedics, dermatology, cardiovascular medicine, and dentistry are also discussed.Methods: A Medline (PubMed search was conducted, and articles published in English were included. Keywords, including “Artelon”, “polyurethanes”, “soft tissue augmentation”, “biocompatibility”, “resorption”, “mechanical stability”, and “complications” were used in different combinations. Titles and abstracts were screened, and full text article analyses were performed.Results: Most of the studies reported orthopedic, dermal, and myocardial applications. There were only a few reports related to dental and implant applications. Artelon has been successfully used for reinforcement of soft tissues, including the rotator cuff, Achilles, patellar, biceps, and quadriceps tendons in orthopedic surgery, and is used clinically for the treatment of osteoarthritis in the hand, wrist, and foot. One type of Artelon material, Artelon Cosmetic, has been used in the dental field to increase soft tissue volume, and stable results are achieved for up to 6 months. This material is reported to be easily handled when cut to the desired shape, with little additional time needed for manipulation during surgery, eliminates the need for connective tissue autografts, and thereby decreases patient morbidity and postoperative discomfort, with increased likelihood of a

  18. Soft computing in computer and information science

    CERN Document Server

    Fray, Imed; Pejaś, Jerzy

    2015-01-01

    This book presents a carefully selected and reviewed collection of papers presented during the 19th Advanced Computer Systems conference ACS-2014. The Advanced Computer Systems conference concentrated from its beginning on methods and algorithms of artificial intelligence. Further future brought new areas of interest concerning technical informatics related to soft computing and some more technological aspects of computer science such as multimedia and computer graphics, software engineering, web systems, information security and safety or project management. These topics are represented in the present book under the categories Artificial Intelligence, Design of Information and Multimedia Systems, Information Technology Security and Software Technologies.

  19. Compact, open-architecture computed radiography system

    International Nuclear Information System (INIS)

    Huang, H.K.; Lim, A.; Kangarloo, H.; Eldredge, S.; Loloyan, M.; Chuang, K.S.

    1990-01-01

    Computed radiography (CR) was introduced in 1982, and its basic system design has not changed. Current CR systems have certain limitations: spatial resolution and signal-to-noise ratios are lower than those of screen-film systems, they are complicated and expensive to build, and they have a closed architecture. The authors of this paper designed and implemented a simpler, lower-cost, compact, open-architecture CR system to overcome some of these limitations. The open-architecture system is a manual-load-single-plate reader that can fit on a desk top. Phosphor images are stored in a local disk and can be sent to any other computer through standard interfaces. Any manufacturer's plate can be read with a scanning time of 90 second for a 35 x 43-cm plate. The standard pixel size is 174 μm and can be adjusted for higher spatial resolution. The data resolution is 12 bits/pixel over an x-ray exposure range of 0.01-100 mR

  20. Preoperative radiotherapy for bone and soft tissue sarcoma

    International Nuclear Information System (INIS)

    Matsumoto, Seiichi; Kawaguchi, Noriyoshi; Amino, Katsuhisa; Manabe, Jun; Yamashita, Takashi; Kaneta, Kouichi; Furuya, Kohtaro; Isobe, Yasushi.

    1989-01-01

    The role of preoperative radiotherapy was evaluated in 16 cases with soft tissue sarcoma and 13 cases with osteosarcoma. Nine osteosarcoma cases underwent radiotherapy of whole lesion, and 4 cases had radiotherapy only of the surgically uncurable portion. There were no local recurrences in M0 cases, but skin necrosis occurred in the whole radiation group. As for the soft tissue sarcomas, local recurrence was not seen in virgin cases, but two cases which had received previous treatment showed local recurrence. There were no cases with severe side effects. Partial radiotherapy was effective as preoperative treatment for osteosarcoma. Preoperative radiotherapy is better than postoperative radiotherapy from many standpoints. (author)

  1. Estimation of soft- and hard-tissue thickness at implant sites

    Directory of Open Access Journals (Sweden)

    Anil Kumar

    2014-01-01

    Full Text Available Introduction: Anchorage control is a critical consideration when planning treatment for patients with dental and skeletal malocclusions. To obtain sufficient stability of implants, the thickness of the soft tissue and the cortical-bone in the placement site must be considered; so as to provide an anatomical map in order to assist the clinician in the placement of the implants. Objective: The aim of this study is to evaluate the thickness of soft- and hard-tissue. Materials and Methods: To measure soft tissue and cortical-bone thicknesses, 12 maxillary cross-sectional specimens were obtained from the cadavers, which were made at three maxillary mid-palatal suture areas: The interdental area between the first and second premolars (Group 1, the second premolar and the first molar (Group 2, and the first and second molars (Group 3. Sectioned samples along with reference rulers were digitally scanned. Scanned images were calibrated and measurements were made with image-analysis software. We measured the thickness of soft and hard-tissues at five sectional areas parallel to the buccopalatal cementoenamel junction (CEJ line at 2-mm intervals and also thickness of soft tissue at the six landmarks including the incisive papilla (IP on the palate. The line perpendicular to the occlusal plane was made and measurement was taken at 4-mm intervals from the closest five points to IP. Results: (1 Group 1:6 mm from CEJ in buccal side and 2 mm from CEJ in palatal side. (2 Group 2:8 mm from CEJ in buccal side and 4 mm from CEJ in palatal side. (3 Group 3:8 mm from CEJ in buccal side and 8 mm from CEJ in palatal side. Conclusions: The best site for placement of implant is with thinnest soft tissue and thickest hard tissue, which is in the middle from CEJ in buccal side and closest from CEJ in palatal side in Group 1 and faraway from CEJ in buccal side and closest from CEJ in palatal side in Group 2 and faraway from CEJ in buccal side and faraway from CEJ in palatal

  2. Digital radiography is promising in industrial testing

    International Nuclear Information System (INIS)

    Del Fabbro, F.

    2015-01-01

    Digital radiography has recently entered the industrial world as a tool for non-destructive testing. There are 3 types of digital radiography: computed radiography (CR), direct radiography (DR) and computed tomography (CT). In computed radiography, traditional silver-halide films are replaced by photostimulable phosphor imaging plates that are activated through laser scanning and digitized. Direct radiography uses a flat panel detector (FPD) composed of X-ray detectors that performs an immediate digital conversion of the image that can be read by a computer. DR is a perfect tool for industrial testing but the fragility of the FPD panels reduces its uses. Computed tomography is based on the principle of DR to get data corresponding to successive cross-section images of the object. These data are processed by a software to get a 3-dimensional image of the object. CT was first developed for medical use but requires some improvement to become more accurate, faster, particularly for big objects. In recent years DR has enjoyed the highest growth rate in digital radiography. (A.C.)

  3. The role of soft computing in intelligent machines.

    Science.gov (United States)

    de Silva, Clarence W

    2003-08-15

    An intelligent machine relies on computational intelligence in generating its intelligent behaviour. This requires a knowledge system in which representation and processing of knowledge are central functions. Approximation is a 'soft' concept, and the capability to approximate for the purposes of comparison, pattern recognition, reasoning, and decision making is a manifestation of intelligence. This paper examines the use of soft computing in intelligent machines. Soft computing is an important branch of computational intelligence, where fuzzy logic, probability theory, neural networks, and genetic algorithms are synergistically used to mimic the reasoning and decision making of a human. This paper explores several important characteristics and capabilities of machines that exhibit intelligent behaviour. Approaches that are useful in the development of an intelligent machine are introduced. The paper presents a general structure for an intelligent machine, giving particular emphasis to its primary components, such as sensors, actuators, controllers, and the communication backbone, and their interaction. The role of soft computing within the overall system is discussed. Common techniques and approaches that will be useful in the development of an intelligent machine are introduced, and the main steps in the development of an intelligent machine for practical use are given. An industrial machine, which employs the concepts of soft computing in its operation, is presented, and one aspect of intelligent tuning, which is incorporated into the machine, is illustrated.

  4. Real-time simulation of biological soft tissues: a PGD approach.

    Science.gov (United States)

    Niroomandi, S; González, D; Alfaro, I; Bordeu, F; Leygue, A; Cueto, E; Chinesta, F

    2013-05-01

    We introduce here a novel approach for the numerical simulation of nonlinear, hyperelastic soft tissues at kilohertz feedback rates necessary for haptic rendering. This approach is based upon the use of proper generalized decomposition techniques, a generalization of PODs. Proper generalized decomposition techniques can be considered as a means of a priori model order reduction and provides a physics-based meta-model without the need for prior computer experiments. The suggested strategy is thus composed of an offline phase, in which a general meta-model is computed, and an online evaluation phase in which the results are obtained at real time. Results are provided that show the potential of the proposed technique, together with some benchmark test that shows the accuracy of the method. Copyright © 2013 John Wiley & Sons, Ltd.

  5. Facial soft tissue thickness database of Gujarati population for forensic craniofacial reconstruction

    Directory of Open Access Journals (Sweden)

    Anand Lodha

    2016-06-01

    Full Text Available The forensic facial reconstruction is a scientific art to construct the ante-mortem face from the human skull. The facial recognition is made by reconstructing the contours of the facial soft tissue thickness (FSTT.These FSTT data are essential for probable face reconstruction but the data of FSTT at particular anthropological landmarks differ in various ethnic groups. Until now several works have been reported on different population but no study exists in which the FSTT of a Gujarati population has been measured. The aim of this study is to compile a set of soft tissue depth data of Gujarati population of India to add to existing literature on FSTT. Computed tomography (CT-scan has been utilized to measure the 25 different FSTT landmarks of 324 male and 165 female. Present study shows significant differences in certain FSTT of Gujarati population from that of other populations. Our compiled data set of FSTT for the Gujarati population is important in understanding craniofacial characteristics of the Gujarati population and potentially be helpful in forensic identification.

  6. International Conference on Soft Computing Systems

    CERN Document Server

    Panigrahi, Bijaya

    2016-01-01

    The book is a collection of high-quality peer-reviewed research papers presented in International Conference on Soft Computing Systems (ICSCS 2015) held at Noorul Islam Centre for Higher Education, Chennai, India. These research papers provide the latest developments in the emerging areas of Soft Computing in Engineering and Technology. The book is organized in two volumes and discusses a wide variety of industrial, engineering and scientific applications of the emerging techniques. It presents invited papers from the inventors/originators of new applications and advanced technologies.

  7. Exatecan in pretreated adult patients with advanced soft tissue sarcoma: results of a phase II--study of the EORTC Soft Tissue and Bone Sarcoma Group

    DEFF Research Database (Denmark)

    Reichardt, P; Nielsen, Ole Steen; Bauer, S

    2007-01-01

    No standard treatment is established for patients with advanced soft tissue sarcoma after previous chemotherapy with anthracyclines and ifosfamide, given either in combination or sequentially. Exatecan (DX-8951f) is a totally synthetic analogue of the topoisomerase I-inhibitor camptothecin, which...... was synthesised to impart increased aqueous solubility, greater tumour efficacy, and less toxicity than camptothecin itself, topotecan or irinotecan. Since some activity against soft tissue sarcomas, especially leiomyosarcomas, has been reported for topoisomerase I-inhibitors, a study with a new and more potent...... agent seemed justified. We report on a prospective multicentre phase II study of Exatecan in adult soft tissue sarcomas failing 1 or 2 lines of chemotherapy in advanced phase, performed within the STBSG of EORTC. Thirty-nine patients (16 leiomyosarcomas and 23 other histologies) were included in two...

  8. Assessment of cone beam CT registration for prostate radiation therapy: fiducial marker and soft tissue methods.

    Science.gov (United States)

    Deegan, Timothy; Owen, Rebecca; Holt, Tanya; Fielding, Andrew; Biggs, Jennifer; Parfitt, Matthew; Coates, Alicia; Roberts, Lisa

    2015-02-01

    This investigation aimed to assess the consistency and accuracy of radiation therapists (RTs) performing cone beam computed tomography (CBCT) alignment to fiducial markers (FMs) (CBCTFM ) and the soft tissue prostate (CBCTST ). Six patients receiving prostate radiation therapy underwent daily CBCTs. Manual alignment of CBCTFM and CBCTST was performed by three RTs. Inter-observer agreement was assessed using a modified Bland-Altman analysis for each alignment method. Clinically acceptable 95% limits of agreement with the mean (LoAmean ) were defined as ±2.0 mm for CBCTFM and ±3.0 mm for CBCTST . Differences between CBCTST alignment and the observer-averaged CBCTFM (AvCBCTFM ) alignment were analysed. Clinically acceptable 95% LoA were defined as ±3.0 mm for the comparison of CBCTST and AvCBCTFM . CBCTFM and CBCTST alignments were performed for 185 images. The CBCTFM 95% LoAmean were within ±2.0 mm in all planes. CBCTST 95% LoAmean were within ±3.0 mm in all planes. Comparison of CBCTST with AvCBCTFM resulted in 95% LoA of -4.9 to 2.6, -1.6 to 2.5 and -4.7 to 1.9 mm in the superior-inferior, left-right and anterior-posterior planes, respectively. Significant differences were found between soft tissue alignment and the predicted FM position. FMs are useful in reducing inter-observer variability compared with soft tissue alignment. Consideration needs to be given to margin design when using soft tissue matching due to increased inter-observer variability. This study highlights some of the complexities of soft tissue guidance for prostate radiation therapy. © 2014 The Royal Australian and New Zealand College of Radiologists.

  9. Assessment of cone beam CT registration for prostate radiation therapy: fiducial marker and soft tissue methods

    International Nuclear Information System (INIS)

    Deegan, Timothy; Owen, Rebecca; Holt, Tanya; Fielding, Andrew; Biggs, Jennifer; Parfitt, Matthew; Coates, Alicia; Roberts, Lisa

    2015-01-01

    This investigation aimed to assess the consistency and accuracy of radiation therapists (RTs) performing cone beam computed tomography (CBCT) alignment to fiducial markers (FMs) (CBCT FM ) and the soft tissue prostate (CBCT ST ). Six patients receiving prostate radiation therapy underwent daily CBCTs. Manual alignment of CBCT FM and CBCT ST was performed by three RTs. Inter-observer agreement was assessed using a modified Bland–Altman analysis for each alignment method. Clinically acceptable 95% limits of agreement with the mean (LoA mean ) were defined as ±2.0 mm for CBCT FM and ±3.0 mm for CBCT ST . Differences between CBCT ST alignment and the observer-averaged CBCT FM (AvCBCT FM ) alignment were analysed. Clinically acceptable 95% LoA were defined as ±3.0 mm for the comparison of CBCT ST and AvCBCT FM . CBCT FM and CBCT ST alignments were performed for 185 images. The CBCT FM 95% LoA mean were within ±2.0 mm in all planes. CBCT ST 95% LoA mean were within ±3.0 mm in all planes. Comparison of CBCT ST with AvCBCT FM resulted in 95% LoA of −4.9 to 2.6, −1.6 to 2.5 and −4.7 to 1.9 mm in the superior–inferior, left–right and anterior–posterior planes, respectively. Significant differences were found between soft tissue alignment and the predicted FM position. FMs are useful in reducing inter-observer variability compared with soft tissue alignment. Consideration needs to be given to margin design when using soft tissue matching due to increased inter-observer variability. This study highlights some of the complexities of soft tissue guidance for prostate radiation therapy.

  10. Extracranial soft-tissue swelling: a normal postmortem radiographic finding or a sign of trauma?

    International Nuclear Information System (INIS)

    Strouse, P.J.; Caplan, M.; Owings, C.L.

    1998-01-01

    Objective. To determine if extracranial soft-tissue swelling is an expected postmortem finding or a sign of trauma. Materials and methods. Extracranial soft-tissue thickness was measured at 5 standardized locations on postmortem skull films obtained of 18 infants with no evidence of trauma on autopsy. The same measurements were performed on the skull films of 100 living children, all less than 3 years old and without clinical history of trauma. Results. Extracranial soft tissues measured only slightly greater in the postmortem group than on films of living children; however, the difference did achieve statistical significance. Conclusion. Minimal extracranial soft-tissue swelling is a normal finding on a postmortem skeletal survey. The presence of substantial or asymmetric extracranial soft-tissue swelling should be viewed with suspicion for trauma. (orig.)

  11. Extracranial soft-tissue swelling: a normal postmortem radiographic finding or a sign of trauma?

    Energy Technology Data Exchange (ETDEWEB)

    Strouse, P.J. [Section of Pediatric Radiology, University of Michigan Medical Center, Ann Arbor (United States); Caplan, M. [Department of Pathology, University of Michigan Medical School, Ann Arbor, Michigan (United States); Owings, C.L. [Department of Pediatrics and Communicable Diseases, C. S. Mott Children`s Hospital, Ann Arbor, Michigan (United States)

    1998-08-01

    Objective. To determine if extracranial soft-tissue swelling is an expected postmortem finding or a sign of trauma. Materials and methods. Extracranial soft-tissue thickness was measured at 5 standardized locations on postmortem skull films obtained of 18 infants with no evidence of trauma on autopsy. The same measurements were performed on the skull films of 100 living children, all less than 3 years old and without clinical history of trauma. Results. Extracranial soft tissues measured only slightly greater in the postmortem group than on films of living children; however, the difference did achieve statistical significance. Conclusion. Minimal extracranial soft-tissue swelling is a normal finding on a postmortem skeletal survey. The presence of substantial or asymmetric extracranial soft-tissue swelling should be viewed with suspicion for trauma. (orig.) With 2 tabs., 5 refs.

  12. Facial soft tissue analysis among various vertical facial patterns

    International Nuclear Information System (INIS)

    Jeelani, W.; Fida, M.; Shaikh, A.

    2016-01-01

    Background: The emergence of soft tissue paradigm in orthodontics has made various soft tissue parameters an integral part of the orthodontic problem list. The purpose of this study was to determine and compare various facial soft tissue parameters on lateral cephalograms among patients with short, average and long facial patterns. Methods: A cross-sectional study was conducted on the lateral cephalograms of 180 adult subjects divided into three equal groups, i.e., short, average and long face according to the vertical facial pattern. Incisal display at rest, nose height, upper and lower lip lengths, degree of lip procumbency and the nasolabial angle were measured for each individual. The gender differences for these soft tissue parameters were determined using Mann-Whitney U test while the comparison among different facial patterns was performed using Kruskal-Wallis test. Results: Significant differences in the incisal display at rest, total nasal height, lip procumbency, the nasolabial angle and the upper and lower lip lengths were found among the three vertical facial patterns. A significant positive correlation of nose and lip dimensions was found with the underlying skeletal pattern. Similarly, the incisal display at rest, upper and lower lip procumbency and the nasolabial angle were significantly correlated with the lower anterior facial height. Conclusion: Short facial pattern is associated with minimal incisal display, recumbent upper and lower lips and acute nasolabial angle while the long facial pattern is associated with excessive incisal display, procumbent upper and lower lips and obtuse nasolabial angle. (author)

  13. Iodine-enhanced micro-CT imaging: methodological refinements for the study of the soft-tissue anatomy of post-embryonic vertebrates.

    Science.gov (United States)

    Gignac, Paul M; Kley, Nathan J

    2014-05-01

    The now widespread use of non-destructive X-ray computed tomography (CT) and micro-CT (µCT) has greatly augmented our ability to comprehensively detail and quantify the internal hard-tissue anatomy of vertebrates. However, the utility of X-ray imaging for gaining similar insights into vertebrate soft-tissue anatomy has yet to be fully realized due to the naturally low X-ray absorption of non-mineralized tissues. In this study, we show how a wide diversity of soft-tissue structures within the vertebrate head-including muscles, glands, fat deposits, perichondria, dural venous sinuses, white and gray matter of the brain, as well as cranial nerves and associated ganglia-can be rapidly visualized in their natural relationships with extraordinary levels of detail using iodine-enhanced (i-e) µCT imaging. To date, Lugol's iodine solution (I2 KI) has been used as a contrast agent for µCT imaging of small invertebrates, vertebrate embryos, and certain isolated parts of larger, post-embryonic vertebrates. These previous studies have all yielded promising results, but visualization of soft tissues in smaller invertebrate and embryonic vertebrate specimens has generally been more complete than that for larger, post-embryonic vertebrates. Our research builds on these previous studies by using high-energy µCT together with more highly concentrated I2 KI solutions and longer staining times to optimize the imaging and differentiation of soft tissues within the heads of post-embryonic archosaurs (Alligator mississippiensis and Dromaius novaehollandiae). We systematically quantify the intensities of tissue staining, demonstrate the range of anatomical structures that can be visualized, and generate a partial three-dimensional reconstruction of alligator cephalic soft-tissue anatomy. © 2014 Wiley Periodicals, Inc.

  14. A continuum mechanics constitutive framework for transverse isotropic soft tissues

    Science.gov (United States)

    Garcia-Gonzalez, D.; Jérusalem, A.; Garzon-Hernandez, S.; Zaera, R.; Arias, A.

    2018-03-01

    In this work, a continuum constitutive framework for the mechanical modelling of soft tissues that incorporates strain rate and temperature dependencies as well as the transverse isotropy arising from fibres embedded into a soft matrix is developed. The constitutive formulation is based on a Helmholtz free energy function decoupled into the contribution of a viscous-hyperelastic matrix and the contribution of fibres introducing dispersion dependent transverse isotropy. The proposed framework considers finite deformation kinematics, is thermodynamically consistent and allows for the particularisation of the energy potentials and flow equations of each constitutive branch. In this regard, the approach developed herein provides the basis on which specific constitutive models can be potentially formulated for a wide variety of soft tissues. To illustrate this versatility, the constitutive framework is particularised here for animal and human white matter and skin, for which constitutive models are provided. In both cases, different energy functions are considered: Neo-Hookean, Gent and Ogden. Finally, the ability of the approach at capturing the experimental behaviour of the two soft tissues is confirmed.

  15. Simplified techniques of cerebral angiography using a mobile X-ray unit and computed radiography

    International Nuclear Information System (INIS)

    Gondo, Gakuji; Ishiwata, Yusuke; Yamashita, Toshinori; Iida, Takashi; Moro, Yutaka

    1989-01-01

    Simplified techniques of cerebral angiography using a mobile X-ray unit and computed radiography (CR) are discussed. Computed radiography is a digital radiography system in which an imaging plate is used as an X-ray detector and a final image is displayed on the film. In the angiograms performed with CR, the spatial frequency components can be enhanced for the easy analysis of fine blood vessels. Computed radiography has an automatic sensitivity and a latitude-setting mechanism, thus serving as an 'automatic camera.' This mechanism is useful for radiography with a mobile X-ray unit in hospital wards, intensive care units, or operating rooms where the appropriate setting of exposure conditions is difficult. We applied this mechanism to direct percutaneous carotid angiography and intravenous digital subtraction angiography with a mobile X-ray unit. Direct percutaneous carotid angiography using CR and a mobile X-ray unit were taken after the manual injection of a small amount of a contrast material through a fine needle. We performed direct percutaneous carotid angiography with this method 68 times on 25 cases from August 1986 to December 1987. Of the 68 angiograms, 61 were evaluated as good, compared with conventional angiography. Though the remaining seven were evaluated as poor, they were still diagnostically effective. This method is found useful for carotid angiography in emergency rooms, intensive care units, or operating rooms. Cerebral venography using CR and a mobile X-ray unit was done after the manual injection of a contrast material through the bilateral cubital veins. The cerebral venous system could be visualized from 16 to 24 seconds after the beginning of the injection of the contrast material. We performed cerebral venography with this method 14 times on six cases. These venograms were better than conventional angiograms in all cases. This method may be useful in managing patients suffering from cerebral venous thrombosis. (J.P.N.)

  16. Ultrasound of musculoskeletal soft-tissue tumors superficial to the investing fascia.

    Science.gov (United States)

    Hung, Esther Hiu Yee; Griffith, James Francis; Ng, Alex Wing Hung; Lee, Ryan Ka Lok; Lau, Domily Ting Yi; Leung, Jason Chi Shun

    2014-06-01

    The objective of our study was to evaluate the diagnostic accuracy of ultrasound in assessing musculoskeletal soft-tissue tumors superficial to the investing fascia. Seven hundred fourteen superficial soft-tissue tumors evaluated with ultrasound by two musculoskeletal radiologists were retrospectively reviewed. In all ultrasound reports, the reporting radiologists provided one, two, or three diagnoses depending on their perceived level of diagnostic certainty. Two hundred forty-seven tumors had subsequent histologic correlation, thus allowing the accuracy of the ultrasound diagnosis to be determined. Images of the lesions with a discordant ultrasound diagnosis and histologic diagnosis were reviewed, and the ultrasound features were further classified as concordant with the known histologic diagnosis, concordant with the known histologic diagnosis with atypical features present, or discordant with the known histologic diagnosis. Four hundred sixty-seven tumors without pathologic confirmation were followed up clinically. Overall the accuracy of ultrasound examination for assessing superficial soft-tissue masses was 79.0% when all differential diagnoses were considered and 77.0% when only the first differential diagnosis was considered. The sensitivity and specificity of the first ultrasound diagnosis were 95.2% and 94.3%, respectively, for lipoma; 73.0% and 97.7% for vascular malformation; 80.0% and 95.4% for epidermoid cyst; and 68.8% and 95.2% for nerve sheath tumor. Reduced observer awareness of specific tumor entities tended to contribute to underdiagnosis more than poor specificity of ultrasound findings. Most tumors (236/247, 96%) were benign. The sensitivity and specificity of ultrasound for identifying malignant superficial soft-tissue tumors was 94.1% and 99.7%, respectively. The diagnostic accuracy of ultrasound in the assessment of superficial musculoskeletal soft-tissue tumors is high and can be improved through increased radiologist awareness of less

  17. Data mining in soft computing framework: a survey.

    Science.gov (United States)

    Mitra, S; Pal, S K; Mitra, P

    2002-01-01

    The present article provides a survey of the available literature on data mining using soft computing. A categorization has been provided based on the different soft computing tools and their hybridizations used, the data mining function implemented, and the preference criterion selected by the model. The utility of the different soft computing methodologies is highlighted. Generally fuzzy sets are suitable for handling the issues related to understandability of patterns, incomplete/noisy data, mixed media information and human interaction, and can provide approximate solutions faster. Neural networks are nonparametric, robust, and exhibit good learning and generalization capabilities in data-rich environments. Genetic algorithms provide efficient search algorithms to select a model, from mixed media data, based on some preference criterion/objective function. Rough sets are suitable for handling different types of uncertainty in data. Some challenges to data mining and the application of soft computing methodologies are indicated. An extensive bibliography is also included.

  18. [Skin and Soft Tissue Infections Due to Corynebacterium ulcerans - Case Reports].

    Science.gov (United States)

    Jenssen, Christian; Schwede, Ilona; Neumann, Volker; Pietsch, Cristine; Handrick, Werner

    2017-10-01

    History and clinical findings  We report on three patients suffering from skin and soft tissue infections of the legs due to toxigenic Corynebacterium ulcerans strains. In all three patients, there was a predisposition due to chronic diseases. Three patients had domestic animals (cat, dog) in their households. Investigations and diagnosis  A mixed bacterial flora including Corynebacterium ulcerans was found in wound swab samples. Diphtheric toxin was produced by the Corynebacterium ulcerans strains in all three cases. Treatment and course  In all three patients, successful handling of the skin and soft tissue infections was possible by combining local treatment with antibiotics. Diphtheria antitoxin was not administered in any case. Conclusion  Based on a review of the recent literature pathogenesis, clinical symptoms and signs, diagnostics and therapy of skin and soft tissue infections due to Corynebacterium ulcerans are discussed. Corynebacterium ulcerans should be considered as a potential cause of severe skin and soft tissue infections. Occupational or domestic animal contacts should be evaluated. © Georg Thieme Verlag KG Stuttgart · New York.

  19. DYSTOCIA DUE TO SOFT TISSUE

    Science.gov (United States)

    DeCarle, Donald W.

    1954-01-01

    In dystocia caused by abnormal conditions of the soft parts, the etiologic changes may be either in the genital tissues or in adjacent soft structures. Broadly, the conditions causing the difficulty may be grouped as follows: (1) anomalies or congenital modifications; (2) tumors; (3) modifications due to age, accident or surgical operations; (4) modification of the expulsive forces; (5) abnormalities of the products of conception. Often in such circumstances cesarean section is necessary. Sometimes when tumor is present it can be removed before it interferes with delivery, but decision to excise the growth must be guided by such factors as the location of the lesion and the stage of gestation. This would determine to what extent the maintenance of pregnancy would be jeopardized by surgical intervention before term. PMID:13190430

  20. Heavy-ion radiography

    International Nuclear Information System (INIS)

    Fabrikant, J.I.; Tobias, C.A.; Holley, W.R.; Benton, E.V.; Woodruff, K.H.; MacFarland, E.W.

    1983-01-01

    High energy, heavy-ion beams offer superior discrimination of tissue electron densities at very low radiation doses. This characteristic has potential for diagnostic medical imaging of neoplasms arising in the soft tissues and organs because it can detect smaller inhomogeneities than x rays. Heavy-ion imaging may also increase the accuracy of cancer radiotherapy planning involving use of accelerated charged particles. In the current physics research program of passive heavy-ion imaging, critical modulation transfer function tests are being carried out in heavy-ion projection radiography and heavy-ion computerized tomography. The research goal is to improve the heavy-ion imaging method until it reaches the limits of its theoretical resolution defined by range straggling, multiple scattering, and other factors involved in the beam quality characteristics. Clinical uses of the imaging method include the application of heavy-ion computerized tomography to heavy-ion radiotherapy planning, to the study of brain tumors and other structures of the head, and to low-dose heavy-ion projection mammography, particularly for women with dense breasts where other methods of diagnosis fail. The ions used are primarily 300 to 570 MeV/amu carbon and neon ions accelerated at the Lawrence Berkeley Laboratory Bevalac

  1. [Epidemiological characteristics and mortality risk factors in patients admitted in hospitals with soft tissue infections. A multicentric STIMG (Soft Tissue Infections Malacitan Group) study results].

    Science.gov (United States)

    Salgado Ordóñez, F; Villar Jiménez, J; Hidalgo Conde, A; Villalobos Sánchez, A; de la Torre Lima, J; Aguilar García, J; da Rocha Costa, I; García Ordóñez, M A; Nuño Alvarez, E; Ramos Cantes, C; Martín Pérez, M

    2006-07-01

    To describe the characteristics of patients admitted in hospitals with soft tissue infections, and analyse the variables whose died, in order to define risk groups. retrospective analysis of medical reports of all patient admitted during 2002 year for soft tissue infections in public malacitans hospitals. We excluded the patient with soft tissue infections associated with burns, surgery, pressure ulcers, and orbit cellulitis. We analysed clinical, biochemical variables and indications for yields and imaging tests, so the empiric antibiotic treatment established and its correlations with practice guidelines. We analysed 391 admissions of 374 patients. Cellulitis was the most frequent diagnosis (69.3%). We did imaging tests in 51.6%. In 94.3% of cases were treated with empirics antibiotics. The most prescribed drug was amoxiciline plus clavulanate (39%). 27 patients died, 40.7% of them for septic cause. All deceased patients had chronic diseases. The only biochemical parameters associated with mortality were serum proteins and albumina (55 +/- 9 g/L vs. 63 +/- 8 g/L; p = 0.0231) and (22 +/- 7 g/L vs. 29 +/- 7 g/L; p = 0.0125) respectively. Cellullitis are the most frequent soft tissue infections that requires admissions in hospitals. We overuse imaging test and don t follow the practice guidelines recommendations in antibiotic therapy. Primary soft issue infection s mortality is low and it s restricted to people with chronic illness, deep infections and bad nutritional status.

  2. Soft tissue anchor systems.

    Science.gov (United States)

    Yu, G V; Chang, T; White, J M

    1994-04-01

    The concept of soft tissue attachment and reattachment has been addressed over the years through a variety of surgical techniques. This includes tendons and ligaments that have been detached both surgically and traumatically from their osseous origins or insertions. This study is designed to provide the reader with a comprehensive overview of current commercially available devices. Detailed descriptions of the various devices are provided along with a discussion of the advantages and disadvantages of each. Their application and use in reconstructive foot and ankle surgery are also discussed.

  3. MR characterization of post-irradiation soft tissue edema

    International Nuclear Information System (INIS)

    Richardson, M.L.; Zink-Brody, G.C.; Patten, R.M.; Koh Wuijin; Conrad, E.U.

    1996-01-01

    Objective. Radiation therapy is often used to treat bone und soft tissue neoplasms, and commonly results in soft tissue edema in the radiation field. However, the time course, distribution and degree of this edema have not been well characterized. Our study was carried out to better define these features of the edema seen following neutron and photon radiation therapy. Results. In general, soft tissue signal intensity in the radiation field initially increased over time, peaking at about 6 months for neutron-treated patients and at about 12-18 months for photon-treated patients. Signal intensity then decreased slowly over time. However, at the end of the follow-up period, signal intensity remained elevated for most patients in both groups. Signal intensity in a particular tissue was greater and tended to persist longer on STIR sequences than on T2-weighted sequences. Survival analysis of signal intensity demonstrated much longer edema survival times for neutron-treated patients than for photon-treated patients. Signal intensity increase in the intramuscular septa persisted for much longer than for fat or muscle. A mild increase in size was noted in the subcutaneous fat and intramuscular septa. Muscle, on the other hand, showed a decrease in size following treatment. This was mild for the photon-treated group and more marked for the neutron-treated group. Conclusions. There is a relatively wide variation in the duration and degree of post-irradiation edema in soft tissues. This edema seems to persist longer in the intramuscular septa than in fat or muscle. Although the duration of follow-up was limited, our study suggests that this edema resolves in roughly half the photon-treated patients within 2-3 years post-treatment and in less than 20% of neutron-treated patients by 3-4 years post-treatment. Muscle atrophy was seen in both photon- and neutron-treated patients, but was more severe in the neutron-treated group. (orig./vhe). With 4 figs

  4. Radiation Effects in Paediatric radiography

    International Nuclear Information System (INIS)

    Mutwasi, O.

    2006-01-01

    Diagnostic imaging has evolved from single technique to a field which we have a choice from many modalities. Some without radiation. Radiation producing modalities include plain films (low dose), Fluoroscopy (mid range dose), Computed tomography (high dose). Radiography dose can significantly be influenced in plain radiography by varying speed of screens, cassette construction and type of radiography. E.g. digital or computed. In computed or digital radiography we are no longer able to tell h igh dose b y the quality of images. The final image is by great extend a product of post processing algorithms. It's for this reasons that the basic understanding of the sensitivity and specifying of various types of examinations and of specifically radiation effects is mandatory for a paediatric imager

  5. MicroRNAs in the Tumor Biology of Soft Tissue Sarcomas

    NARCIS (Netherlands)

    C.M.M. Gits (Caroline)

    2013-01-01

    markdownabstract__Abstract__ Soft tissue sarcomas represent a rare, heterogeneous group of mesenchymal tumors. In sarcomas, histological classification, prediction of clinical behaviour and prognosis, and targeted treatment is often a challenge. A better understanding of the biology of soft

  6. Soft Tissue Surgical Procedures for Optimizing Anterior Implant Esthetics

    Science.gov (United States)

    Ioannou, Andreas L.; Kotsakis, Georgios A.; McHale, Michelle G.; Lareau, Donald E.; Hinrichs, James E.; Romanos, Georgios E.

    2015-01-01

    Implant dentistry has been established as a predictable treatment with excellent clinical success to replace missing or nonrestorable teeth. A successful esthetic implant reconstruction is predicated on two fundamental components: the reproduction of the natural tooth characteristics on the implant crown and the establishment of soft tissue housing that will simulate a healthy periodontium. In order for an implant to optimally rehabilitate esthetics, the peri-implant soft tissues must be preserved and/or augmented by means of periodontal surgical procedures. Clinicians who practice implant dentistry should strive to achieve an esthetically successful outcome beyond just osseointegration. Knowledge of a variety of available techniques and proper treatment planning enables the clinician to meet the ever-increasing esthetic demands as requested by patients. The purpose of this paper is to enhance the implant surgeon's rationale and techniques beyond that of simply placing a functional restoration in an edentulous site to a level whereby an implant-supported restoration is placed in reconstructed soft tissue, so the site is indiscernible from a natural tooth. PMID:26124837

  7. Medical image of the week: necrotizing soft tissue infection

    Directory of Open Access Journals (Sweden)

    Taylor A

    2016-03-01

    Full Text Available No abstract available. Article truncated at 150 words. A 70-year-old man with a history of coronary artery disease, chronic back pain, and general debilitation presented to the emergency department with complaints of fever, weakness and right buttock discomfort. Physical exam was remarkable for a temperature of 101.7º F, and for moderate erythema of the skin of the right inguinal area and right buttock, with associated tenderness. Laboratory exam was significant for a WBC of 22.7 K/ɥL, erythrocyte sedimentation rate of 82 mm, and serum creatinine phosphokinase of 2856 U/L. CAT of the abdomen and pelvis demonstrated extensive gluteal and perineal soft tissue inflammation with gas formation, consistent with a necrotizing soft tissue infection (Figures 1 and 2. Three basic subsets of necrotizing soft tissue infections (NSTIs have been described. Type I infections are the most common form and are characterized by a polymicrobial process typically involving gram positive cocci, gram negative rods, and anaerobes. Type I infections occur ...

  8. Reconstruction of soft tissue after complicated calcaneal fractures.

    Science.gov (United States)

    Koski, E Antti; Kuokkanen, Hannu O M; Koskinen, Seppo K; Tukiainen, Erkki J

    2004-01-01

    A total of 35 flap reconstructions were done to cover exposed calcaneal bones in 31 patients. All patients had calcaneal fractures, 19 of which were primarily open. Soft tissue reconstruction for the closed fractures was indicated by a postoperative wound complication. A microvascular flap was used for reconstruction in 21 operations (gracilis, n = 11; anterolateral thigh, n = 5; rectus abdominis, n = 3; and latissimus dorsi, n = 2). A suralis neurocutaneous flap was used in eight, local muscle flaps in three, and local skin flaps in three cases. The mean follow-up time was 14 months (range 3 months-4 years). One suralis flap failed and was replaced by a latissimus dorsi flap. Necrosis of the edges that required revision affected three flaps. Deep infection developed in two patients and delayed wound healing in another four. During the follow-up the soft tissues healed in all patients and there were no signs of calcaneal osteitis. Flaps were considered too bulky in five patients. Soft tissues heal most rapidly with microvascular flaps. In the long term, gracilis muscle covered with free skin grafts gives a good contour to the foot. The suralis flap is reliable and gives a good final aesthetic outcome. Local muscles can be transposed for reconstruction in small defects.

  9. Pazopanib for the treatment of soft-tissue sarcoma

    Directory of Open Access Journals (Sweden)

    Heudel P

    2012-10-01

    Full Text Available Pierre Heudel,1 Philippe Cassier,1 Olfa Derbel,1 Armelle Dufresne,1 Pierre Meeus,2 Philippe Thiesse,3 Dominique Ranchère-Vince,4 Jean Yves Blay,1 Isabelle Ray-Coquard1,51Department of Medical Oncology, 2Department of Surgical Oncology, 3Department of Radiology, 4Department of Pathology, Leon Berard Center, Lyon, 5EAM 4128 Sante-Individu-Societe, Lyon University, Lyon, FranceAbstract: Pazopanib is a multikinase inhibitor which potently inhibits the activity of major receptor tyrosine kinases, including vascular endothelial growth factor receptor-1, vascular endothelial growth factor receptor-2, vascular endothelial growth factor receptor-3, platelet-derived growth factor receptor-a, platelet-derived growth factor receptor-a, and c-Kit. Approved by the Food and Drug Administration in 2009 in the United States for the treatment of metastatic renal cell carcinoma, pazopanib has been tested in advanced or metastatic soft-tissue sarcoma. Unlike other tyrosine kinase inhibitors, a statistically significant efficacy in phase II but also in randomized phase III studies has been shown. In comparison with sunitinib or sorafenib, pazopanib has a similar toxicity profile and is generally well tolerated. This review details the development of this new therapeutic class in the treatment of metastatic soft-tissue sarcomas.Keywords: soft-tissue sarcoma, pazopanib, tyrosine kinase inhibitor

  10. Computed radiography in neonatal intensive care

    International Nuclear Information System (INIS)

    Merlo, L.; Bighi, S.; Cervi, P.M.; Lupi, L.

    1991-01-01

    The Authors report their experience in the employment of a computerized digital radiographic system in Neonatal Intensive Care. The analog screen-film system is replaced by photosensitive imaging plates, scanned after X-ray exposure by a laser that releases the digital image, which can then be manipulated on computer work-stations. In a period of twelve months about 200 chest-abdomen X-ray examinations in Neonatal Intensive Care have been performed using this method with good technical and diagnostic results. The use of digital radiography in the neonatal area is of high interest: this system produces good quality images, there is a reduction in radiation dose and 'retakes', the system allows selective enhancement of different structures and their magnification. (orig.)

  11. Use of synchrotron-based diffraction-enhanced imaging for visualization of soft tissues in invertebrates

    International Nuclear Information System (INIS)

    Rao, Donepudi V.; Swapna, Medasani; Cesareo, Roberto; Brunetti, Antonio; Zhong, Zhong; Akatsuka, Takao; Yuasa, Tetsuya; Takeda, Tohoru; Gigante, Giovanni E.

    2010-01-01

    Images of terrestrial and marine invertebrates (snails and bivalves) have been obtained by using an X-ray phase-contrast imaging technique, namely, synchrotron-based diffraction-enhanced imaging. Synchrotron X-rays of 20, 30 and 40 keV were used, which penetrate deep enough into animal soft tissues. The phase of X-ray photons shifts slightly as they traverse an object, such as animal soft tissue, and interact with its atoms. Biological features, such as shell morphology and animal physiology, have been visualized. The contrast of the images obtained at 40 keV is the best. This optimum energy provided a clear view of the internal structural organization of the soft tissue with better contrast. The contrast is higher at edges of internal soft-tissue structures. The image improvements achieved with the diffraction-enhanced imaging technique are due to extinction, i.e., elimination of ultra-small-angle scattering. They enabled us to identify a few embedded internal shell features, such as the origin of the apex, which is the firmly attached region of the soft tissue connecting the umbilicus to the external morphology. Diffraction-enhanced imaging can provide high-quality images of soft tissues valuable for biology.

  12. Use of synchrotron-based diffraction-enhanced imaging for visualization of soft tissues in invertebrates

    Energy Technology Data Exchange (ETDEWEB)

    Rao, Donepudi V., E-mail: donepudi_venkateswararao@rediffmail.co [Istituto di Matematica e Fisica, Universita degli Studi di Sassari, Via Vienna 2, 07100 Sassari (Italy); Swapna, Medasani, E-mail: medasanisw@gmail.co [Istituto di Matematica e Fisica, Universita degli Studi di Sassari, Via Vienna 2, 07100 Sassari (Italy); Cesareo, Roberto; Brunetti, Antonio [Istituto di Matematica e Fisica, Universita degli Studi di Sassari, Via Vienna 2, 07100 Sassari (Italy); Zhong, Zhong [National Synchrotron Light Source, Brookhaven National Laboratory, Upton, NY 11973 (United States); Akatsuka, Takao; Yuasa, Tetsuya [Department of Bio-System Engineering, Faculty of Engineering, Yamagata University, Yonezawa-shi, Yamagata-992-8510 (Japan); Takeda, Tohoru [Allied Health Science, Kitasato University 1-15-1 Kitasato, Sagamihara, Kanagawa 228-8555 (Japan); Gigante, Giovanni E. [Dipartimento di Fisica, Universita di Roma, La Sapienza, 00185 Roma (Italy)

    2010-09-15

    Images of terrestrial and marine invertebrates (snails and bivalves) have been obtained by using an X-ray phase-contrast imaging technique, namely, synchrotron-based diffraction-enhanced imaging. Synchrotron X-rays of 20, 30 and 40 keV were used, which penetrate deep enough into animal soft tissues. The phase of X-ray photons shifts slightly as they traverse an object, such as animal soft tissue, and interact with its atoms. Biological features, such as shell morphology and animal physiology, have been visualized. The contrast of the images obtained at 40 keV is the best. This optimum energy provided a clear view of the internal structural organization of the soft tissue with better contrast. The contrast is higher at edges of internal soft-tissue structures. The image improvements achieved with the diffraction-enhanced imaging technique are due to extinction, i.e., elimination of ultra-small-angle scattering. They enabled us to identify a few embedded internal shell features, such as the origin of the apex, which is the firmly attached region of the soft tissue connecting the umbilicus to the external morphology. Diffraction-enhanced imaging can provide high-quality images of soft tissues valuable for biology.

  13. Soft tissue healing in alveolar socket preservation technique: histologic evaluations.

    Science.gov (United States)

    Pellegrini, Gaia; Rasperini, Giulio; Obot, Gregory; Farronato, Davide; Dellavia, Claudia

    2014-01-01

    After tooth extraction, 14 alveolar sockets were grafted with porous bovine bone mineral particles and covered with non-cross-linked collagen membrane (test group), and 14 alveolar sockets were left uncovered. At 5 and 12 weeks, microvascular density (MVD), collagen content, and amount of lymphocytes (Lym) T and B were analyzed in soft tissue. At 5 weeks, MVD was significantly lower and Lym T was significantly higher in tests than in controls (P healing process of the soft tissue.

  14. Study of distribution dose for chest radiography using the computational model ALDERSON/EGSnrc

    International Nuclear Information System (INIS)

    Muniz, B.C.; Menezes, C.J.M.

    2017-01-01

    Numerical dosimetry uses Computational Exposure Models (MCE) to perform dose studies in situations of radiation exposure without the need for individuals to be exposed. MCEs are essentially composed of a simulator of the radioactive source, a Monte Carlo code, and a phantom of voxels representing the human anatomy. The objective of this work was to perform a study of the dose distribution in the thoracic region in radiographic exams using the MCE ALDERSON / EGSnrc. For that, virtual simulations were performed using Monte Carlo Method techniques to calculate the dose in the simulator of voxels representative of the thoracic region. The results show that most beam energy was deposited in the skeleton for all simulated radiological techniques, while smaller fractions were deposited in the lungs and soft tissue. For example, at 90 kV voltage, 14% of the energy was deposited in the bone medium, while lungs and soft tissue receive only 5 and 3%, respectively. It is concluded that the ALDERSON / EGSnrc MCE can be used for studies of the dose distribution on chest radiographs used in radiodiagnosis practice, thus optimizing dose absorbed in the patient in clinical exams

  15. Characterization of Soft Tissue Tumors by Diffusion-Weighted Imaging

    International Nuclear Information System (INIS)

    Pekcevik, Yeliz; Kahya, Mehmet Onur; Kaya, Ahmet

    2015-01-01

    Diffusion-weighted imaging (DWI) is a noninvasive method for investigation of tumor histological content. It has been applied for some musculoskeletal tumors and reported to be useful. The aim of the present study was to prospectively evaluate the apparent diffusion coefficient (ADC) values of benign and malignant soft tissue tumors and to determine if ADC can help differentiate these tumors. DWI was performed on 25 histologically proven soft tissue masses. It was obtained with a single-shot echo-planar imaging technique using a 1.5T magnetic resonance (MR) machine. The mean ADC values were calculated. We grouped soft tissue tumors as benign cystic, benign solid or mixed, malignant cystic and malignant solid or mixed tumors and compared mean ADC values between these groups. There was only one patient with a malignant cystic tumor and was not included in the statistical analysis. The median ADC values of benign and malignant tumors were 2.31 ± 1.29 and 0.90 ± 0.70 (median ± interquartile range), respectively. The mean ADC values were different between benign and malignant tumors (P = 0.031). Benign cystic tumors had significantly higher ADC values than benign solid or mixed tumors and malignant solid or mixed tumors (p values were < 0.001 and 0.003, respectively). Malignant solid or mixed tumors had lower ADC values than benign solid or mixed tumors (P = 0.02). Our preliminary results have shown that although there is some overlap between benign and malignant tumors, adding DWI, MR imaging to routine soft tissue tumor protocols may improve diagnostic accuracy

  16. Soft computing in green and renewable energy systems

    Energy Technology Data Exchange (ETDEWEB)

    Gopalakrishnan, Kasthurirangan [Iowa State Univ., Ames, IA (United States). Iowa Bioeconomy Inst.; US Department of Energy, Ames, IA (United States). Ames Lab; Kalogirou, Soteris [Cyprus Univ. of Technology, Limassol (Cyprus). Dept. of Mechanical Engineering and Materials Sciences and Engineering; Khaitan, Siddhartha Kumar (eds.) [Iowa State Univ. of Science and Technology, Ames, IA (United States). Dept. of Electrical Engineering and Computer Engineering

    2011-07-01

    Soft Computing in Green and Renewable Energy Systems provides a practical introduction to the application of soft computing techniques and hybrid intelligent systems for designing, modeling, characterizing, optimizing, forecasting, and performance prediction of green and renewable energy systems. Research is proceeding at jet speed on renewable energy (energy derived from natural resources such as sunlight, wind, tides, rain, geothermal heat, biomass, hydrogen, etc.) as policy makers, researchers, economists, and world agencies have joined forces in finding alternative sustainable energy solutions to current critical environmental, economic, and social issues. The innovative models, environmentally benign processes, data analytics, etc. employed in renewable energy systems are computationally-intensive, non-linear and complex as well as involve a high degree of uncertainty. Soft computing technologies, such as fuzzy sets and systems, neural science and systems, evolutionary algorithms and genetic programming, and machine learning, are ideal in handling the noise, imprecision, and uncertainty in the data, and yet achieve robust, low-cost solutions. As a result, intelligent and soft computing paradigms are finding increasing applications in the study of renewable energy systems. Researchers, practitioners, undergraduate and graduate students engaged in the study of renewable energy systems will find this book very useful. (orig.)

  17. Soft Tissue Coverage of the Lower Limb following Oncological Surgery.

    Science.gov (United States)

    Radtke, Christine; Panzica, Martin; Dastagir, Khaled; Krettek, Christian; Vogt, Peter M

    2015-01-01

    The treatment of lower limb tumors has been shifted by advancements in adjuvant treatment protocols and microsurgical reconstruction from limb amputation to limb salvage. Standard approaches include oncological surgery by a multidisciplinary team in terms of limb sparing followed by soft tissue reconstruction and adjuvant therapy when indicated. For the development of a comprehensive surgical plan, the identity of the tumor should first be determined by histology after biopsy. Then the surgical goal and comprehensive treatment concept should be developed by a multidisciplinary tumor board and combined with soft tissue reconstruction. In this article, plastic surgical reconstruction options for soft coverage of the lower extremity following oncological surgery will be described along with the five clinical cases.

  18. Soft tissue coverage of the lower limb following oncological surgery

    Directory of Open Access Journals (Sweden)

    Christine eRadtke

    2016-01-01

    Full Text Available The treatment of lower limb tumours has been shifted by advancements in adjuvant treatment protocols and microsurgical reconstruction from limb amputation to limb salvage. Standard approaches include oncological surgery by a multidisciplinary team in terms of limb sparing followed by soft tissue reconstruction and adjuvant therapy when indicated. For development of a comprehensive surgical plan, the identity of the tumour should first be determined by histology after biopsy. Then the surgical goal and comprehensive treatment concept should be developed by a multidisciplinary tumour board and combined with soft tissue reconstruction. In this article, plastic surgical reconstruction options for soft coverage of the lower extremity following oncologic surgery will be described along with five clinical cases.

  19. 4th International Conference on Quantitative Logic and Soft Computing

    CERN Document Server

    Chen, Shui-Li; Wang, San-Min; Li, Yong-Ming

    2017-01-01

    This book is the proceedings of the Fourth International Conference on Quantitative Logic and Soft Computing (QLSC2016) held 14-17, October, 2016 in Zhejiang Sci-Tech University, Hangzhou, China. It includes 61 papers, of which 5 are plenary talks( 3 abstracts and 2 full length talks). QLSC2016 was the fourth in a series of conferences on Quantitative Logic and Soft Computing. This conference was a major symposium for scientists, engineers and practitioners to present their updated results, ideas, developments and applications in all areas of quantitative logic and soft computing. The book aims to strengthen relations between industry research laboratories and universities in fields such as quantitative logic and soft computing worldwide as follows: (1) Quantitative Logic and Uncertainty Logic; (2) Automata and Quantification of Software; (3) Fuzzy Connectives and Fuzzy Reasoning; (4) Fuzzy Logical Algebras; (5) Artificial Intelligence and Soft Computing; (6) Fuzzy Sets Theory and Applications.

  20. Water demand forecasting: review of soft computing methods.

    Science.gov (United States)

    Ghalehkhondabi, Iman; Ardjmand, Ehsan; Young, William A; Weckman, Gary R

    2017-07-01

    Demand forecasting plays a vital role in resource management for governments and private companies. Considering the scarcity of water and its inherent constraints, demand management and forecasting in this domain are critically important. Several soft computing techniques have been developed over the last few decades for water demand forecasting. This study focuses on soft computing methods of water consumption forecasting published between 2005 and 2015. These methods include artificial neural networks (ANNs), fuzzy and neuro-fuzzy models, support vector machines, metaheuristics, and system dynamics. Furthermore, it was discussed that while in short-term forecasting, ANNs have been superior in many cases, but it is still very difficult to pick a single method as the overall best. According to the literature, various methods and their hybrids are applied to water demand forecasting. However, it seems soft computing has a lot more to contribute to water demand forecasting. These contribution areas include, but are not limited, to various ANN architectures, unsupervised methods, deep learning, various metaheuristics, and ensemble methods. Moreover, it is found that soft computing methods are mainly used for short-term demand forecasting.

  1. 6th International Conference on Soft Computing for Problem Solving

    CERN Document Server

    Bansal, Jagdish; Das, Kedar; Lal, Arvind; Garg, Harish; Nagar, Atulya; Pant, Millie

    2017-01-01

    This two-volume book gathers the proceedings of the Sixth International Conference on Soft Computing for Problem Solving (SocProS 2016), offering a collection of research papers presented during the conference at Thapar University, Patiala, India. Providing a veritable treasure trove for scientists and researchers working in the field of soft computing, it highlights the latest developments in the broad area of “Computational Intelligence” and explores both theoretical and practical aspects using fuzzy logic, artificial neural networks, evolutionary algorithms, swarm intelligence, soft computing, computational intelligence, etc.

  2. Clinical Presentation of Soft-tissue Infections and its Management: A Study of 100 Cases.

    Science.gov (United States)

    Singh, Baldev; Singh, Sukha; Khichy, Sudhir; Ghatge, Avinash

    2017-01-01

    Soft-tissue infections vary widely in their nature and severity. A clear approach to the management must allow their rapid identification and treatment as they can be life-threatening. Clinical presentation of soft-tissue infections and its management. A prospective study based on 100 patients presenting with soft-tissue infections was done. All the cases of soft-tissue infections were considered irrespective of age, sex, etiological factors, or systemic disorders. The findings were evaluated regarding the pattern of soft-tissue infections in relation to age and sex, clinical presentation, complications, duration of hospital stay, management, and mortality. The most commonly involved age group was in the range of 41-60 years with male predominance. Abscess formation (45%) was the most common clinical presentation. Type 2 diabetes mellitus was the most common associated comorbid condition. Staphylococcus aureus was the most common culture isolate obtained. The most common complication seen was renal failure. Patients with surgical site infections had maximum duration of stay in the hospital. About 94% of the cases of soft-tissue infections were managed surgically. Mortality was mostly encountered in the cases of complications of cellulitis. Skin and soft-tissue infections are among the most common infections encountered by the emergency physicians. Ignorance, reluctance to treatment, economic constraints, and illiteracy delay the early detection and the initiation of proper treatment. Adequate and timely surgical intervention in most of the cases is of utmost importance to prevent the complications and reduce the mortality.

  3. Highly sensitive detection of the soft tissues based on refraction contrast by in-plane diffraction-enhanced imaging CT

    International Nuclear Information System (INIS)

    Yuasa, Tetsuya; Hashimoto, Eiko; Maksimenko, Anton; Sugiyama, Hiroshi; Arai, Yoshinori; Shimao, Daisuke; Ichihara, Shu; Ando, Masami

    2008-01-01

    We discuss the recently proposed computed tomography (CT) technique based on refractive effects for biomedical use, which reconstructs the in-plane refractive-index gradient vector field in a cross-sectional plane of interest by detecting the angular deviation of the beam, refracted by a sample, from the incident beam, using the diffraction-enhanced imaging (DEI) method. The CT has advantages for delineating biological weakly absorbing soft tissues over the conventional absorption-contrast CT because of the use of phase sensitive detection. The paper aims to define the imaging scheme rigidly and to demonstrate its efficacy for non-destructive measurement of biomedical soft-tissue samples without imaging agent. We first describe the imaging principle of in-plane DEI-CT from the physico-mathematical viewpoints in detail, and investigate what physical quantities are extracted from the reconstructed images. Then, we introduce the imaging system using the synchrotron radiation as a light source, constructed at beamline BL-14B in KEK, Japan. Finally, we demonstrate the advantage of the refraction-based image for non-destructive analysis of biological sample by investigating the image of human breast cancer tumors obtained using the imaging system. Here, the refraction- and the apparent absorption-based images obtained simultaneously by the in-plane DEI-CT are compared. Also, the conventional absorption-based image obtained using micro-computed tomography (μCT) imaging system is compared with them. Thereby, it is shown that the refraction contrast much more sensitively delineates the soft tissues than the absorption contrast. In addition, the radiologic-histologic correlation study not only validates the efficacy for imaging soft tissues, but also produces the potential that the pathological inspection for the breast cancer tumors may be feasible non-destructively

  4. Bone and Soft Tissue Changes after Two-Jaw Surgery in Cleft Patients

    Directory of Open Access Journals (Sweden)

    Yung Sang Yun

    2015-07-01

    Full Text Available BackgroundOrthognathic surgery is required in 25% to 35% of patients with a cleft lip and palate, for whom functional recovery and aesthetic improvement after surgery are important. The aim of this study was to examine maxillary and mandibular changes, along with concomitant soft tissue changes, in cleft patients who underwent LeFort I osteotomy and sagittal split ramus osteotomy (two-jaw surgery.MethodsTwenty-eight cleft patients who underwent two-jaw surgery between August 2008 and November 2013 were included. Cephalometric analysis was conducted before and after surgery. Preoperative and postoperative measurements of the bone and soft tissue were compared.ResultsThe mean horizontal advancement of the maxilla (point A was 6.12 mm, while that of the mandible (point B was -5.19 mm. The mean point A-nasion-point B angle was -4.1° before surgery, and increased to 2.5° after surgery. The mean nasolabial angle was 72.7° before surgery, and increased to 88.7° after surgery. The mean minimal distance between Rickett's E-line and the upper lip was 6.52 mm before surgery and 1.81 mm after surgery. The ratio of soft tissue change to bone change was 0.55 between point A and point A' and 0.93 between point B and point B'.ConclusionsPatients with cleft lip and palate who underwent two-jaw surgery showed optimal soft tissue changes. The position of the soft tissue (point A' was shifted by a distance equal to 55% of the change in the maxillary bone. Therefore, bone surgery without soft tissue correction can achieve good aesthetic results.

  5. Quantitative dynamic ¹⁸FDG-PET and tracer kinetic analysis of soft tissue sarcomas.

    Science.gov (United States)

    Rusten, Espen; Rødal, Jan; Revheim, Mona E; Skretting, Arne; Bruland, Oyvind S; Malinen, Eirik

    2013-08-01

    To study soft tissue sarcomas using dynamic positron emission tomography (PET) with the glucose analog tracer [(18)F]fluoro-2-deoxy-D-glucose ((18)FDG), to investigate correlations between derived PET image parameters and clinical characteristics, and to discuss implications of dynamic PET acquisition (D-PET). D-PET images of 11 patients with soft tissue sarcomas were analyzed voxel-by-voxel using a compartment tracer kinetic model providing estimates of transfer rates between the vascular, non-metabolized, and metabolized compartments. Furthermore, standard uptake values (SUVs) in the early (2 min p.i.; SUVE) and late (45 min p.i.; SUVL) phases of the PET acquisition were obtained. The derived transfer rates K1, k2 and k3, along with the metabolic rate of (18)FDG (MRFDG) and the vascular fraction νp, was fused with the computed tomography (CT) images for visual interpretation. Correlations between D-PET imaging parameters and clinical parameters, i.e. tumor size, grade and clinical status, were calculated with a significance level of 0.05. The temporal uptake pattern of (18)FDG in the tumor varied considerably from patient to patient. SUVE peak was higher than SUVL peak for four patients. The images of the rate constants showed a systematic pattern, often with elevated intensity in the tumors compared to surrounding tissue. Significant correlations were found between SUVE/L and some of the rate parameters. Dynamic (18)FDG-PET may provide additional valuable information on soft tissue sarcomas not obtainable from conventional (18)FDG-PET. The prognostic role of dynamic imaging should be investigated.

  6. Phoneme-based speech segmentation using hybrid soft computing framework

    CERN Document Server

    Sarma, Mousmita

    2014-01-01

    The book discusses intelligent system design using soft computing and similar systems and their interdisciplinary applications. It also focuses on the recent trends to use soft computing as a versatile tool for designing a host of decision support systems.

  7. Computer radiography-X-ray with vision

    International Nuclear Information System (INIS)

    Waitiki, C.

    2006-01-01

    Computer radiography describes an entire process of creating a digital image including acquiring, processing, presenting and managing the image data. the cassettes are special in that they use an imaging plate instead of films. the imaging plate is coated with storage phosphors which captures x-ray as they pass through the patient. the imaging plate is read with a bar code reader and the imaging plate number recorded in the computer. The cassette is then loaded in the reader unit where it is read using infra-red light which excites the particles on the plate which in turn illuminates and picked by photo-sensors which converts the signal into digital pulses. the pulses then run through a board which converts it into an image which is then displayed on the control console. The plate then runs through the erasure section where it is exposed to yellow light, which erases the plate. The IP is then put back in the cassette and locked and can be reused for the next episode

  8. Recent developments and new directions in soft computing

    CERN Document Server

    Abbasov, Ali; Yager, Ronald; Shahbazova, Shahnaz; Reformat, Marek

    2014-01-01

    The book reports on the latest advances and challenges of soft computing. It  gathers original scientific contributions written by top scientists in the field and covering theories, methods and applications in a number of research areas related to soft-computing, such as decision-making, probabilistic reasoning, image processing, control, neural networks and data analysis.  

  9. Angular photogrammetric soft tissue facial profile analysis of Bangladeshi young adults

    Directory of Open Access Journals (Sweden)

    Lubna Akter

    2017-01-01

    Full Text Available Introduction: Angular photogrammetric soft tissue facial profile analysis provides a permanent record for the actual appearance of a person, which would also serve to establish an ideal esthetic treatment goal. The aim of the present study was to evaluate the average angular variables that define the soft tissue facial profile of a Bangladeshi sample. Materials and Methods: This cross-sectional study was carried out at Department of Orthodontics and Dentofacial Orthopedics of Dhaka Dental College and Hospital, Bangladesh, from July to December 2015. Soft tissue facial profiles of 200 participants (100 males and 100 females between 18 and 25 years of age, with a dental Class I occlusal relationship and harmonious soft tissue profile, were selected by convenience sampling among students, doctors, and patients of Dhaka Dental College. Standardized photographs of 200 samples were taken in the natural head position. The photographic records were analyzed with the software for Windows, Microsoft Visio 2007, Standard Edition. All data were analyzed through standard methods using Statistical Package for the Statistical Package for Social Science Software (SPSS Version-20, IBM Corp, USA. Results: The average angular measurements for nasofrontal, total facial angle, facial angle, upper lip angle, projection of lower lip to chin, and mentolabial angle were wider in females. The mean value for nose tip angle, nasolabial angle, nasomental angle, and projection of upper lip to chin angle was higher in males compared to females. Nasofrontal angle (G-N-Nd (P = 0.000 and mentolabial angle (Li-Sm-Pg (P = 0.001 showed statistically significant differences. The greatest variability was found for mentolabial angle. Conclusion: The study of angular photogrammetric soft tissue facial profile analysis of Bangladeshi young adults contributes to the establishment of standardized normal values for the population. This study provides data which can be used in treatment

  10. The role of the plain radiograph in the characterisation of soft tissue tumours

    International Nuclear Information System (INIS)

    Gartner, Louise; Saifuddin, Asif; Pearce, Christopher J.

    2009-01-01

    A radiograph is often the first investigation to be requested when a patient presents with limb pain or a mass. Whilst we do not advocate that this is the only investigation to be employed in the evaluation of such patients, a working knowledge of the variety of abnormal findings that can present in the soft tissues on radiographs remains useful. We reviewed the radiographic findings of soft tissue masses from a prospectively compiled database of all such lesions presenting to a specialist orthopaedic oncology service over the past 8 years. Of the cohort of 1,058 individuals with a proven soft tissue tumour, 454 had had a radiograph taken of the affected area. Of these, 281 (62%) patients had a positive radiographic finding. The most common findings were a visible soft tissue mass (n = 141), the presence of calcification (n = 76), fat (n = 32) and evidence of bone involvement (n = 62). More than one finding was sometimes present in the same patient. These findings were present in both benign and malignant tumours. This review article describes the incidence and diagnostic relevance of these plain film findings for suspected soft tissue tumours. (orig.)

  11. Adverse reactions to injectable soft tissue fillers

    DEFF Research Database (Denmark)

    Requena, Luis; Requena, Celia; Christensen, Lise

    2011-01-01

    In recent years, injections with filler agents are often used for wrinkle-treatment and soft tissue augmentation by dermatologists and plastic surgeons. Unfortunately, the ideal filler has not yet been discovered and all of them may induce adverse reactions. Quickly biodegradable or resorbable ag...

  12. Biodegradable elastomeric scaffolds for soft tissue engineering

    NARCIS (Netherlands)

    Pêgo, A.P.; Poot, Andreas A.; Grijpma, Dirk W.; Feijen, Jan

    2003-01-01

    Elastomeric copolymers of 1,3-trimethylene carbonate (TMC) and ε-caprolactone (CL) and copolymers of TMC and D,L-lactide (DLLA) have been evaluated as candidate materials for the preparation of biodegradable scaffolds for soft tissue engineering. TMC-DLLA copolymers are amorphous and degrade more

  13. On clinical usefulness of Tl-201 scintigraphy for the management of malignant soft tissue tumors

    International Nuclear Information System (INIS)

    Terui, Shoji; Terauchi, Takashi; Abe, Hiroyuki; Fukuma, Hisatoshi; Beppu, Yasuo; Chuman, Koichi; Yokoyama, Ryohei

    1994-01-01

    The purpose of this study was to investigate Tl-201 as a tumor scanning agent in patients with malignant soft tissue sarcomas and to establish the sensitivity of this type of scintigraphy concerning local recurrences or metastases that may remain clinically suspected. Seventy-eight patients with malignant soft tissue sarcomas and 22 with benign soft tissue tumors were studied. Of these 78 malignant soft tissue sarcomas patients, the sensitivity of Tl-201 (81.2%) was higher than that of Ga-67 (68.8%). Thirty-three out of 78 patients received a total of 95 consecutive scintigraphic follow-up examinations. Therapeutic effects was assessed by comparing the results of Tl-201 examinations with the clinical findings. Of these 33 patients, the therapeutic effects observed were as follows: complete remission 1, partial remission 8, progress of disease 1, and no remarkable change 23. Tl-201 scintigraphy has proved itself very useful not only in clinically detecting the malignant soft tissue sarcomas and in assessing therapeutic effects on these diseases, but also in assessing the follow-up patients with malignant soft tissue sarcomas. (author)

  14. Comparison of Diagnostic Performance of Semi-Quantitative Knee Ultrasound and Knee Radiography with MRI: Oulu Knee Osteoarthritis Study

    Science.gov (United States)

    Podlipská, Jana; Guermazi, Ali; Lehenkari, Petri; Niinimäki, Jaakko; Roemer, Frank W.; Arokoski, Jari P.; Kaukinen, Päivi; Liukkonen, Esa; Lammentausta, Eveliina; Nieminen, Miika T.; Tervonen, Osmo; Koski, Juhani M.; Saarakkala, Simo

    2016-01-01

    Osteoarthritis (OA) is a common degenerative musculoskeletal disease highly prevalent in aging societies worldwide. Traditionally, knee OA is diagnosed using conventional radiography. However, structural changes of articular cartilage or menisci cannot be directly evaluated using this method. On the other hand, ultrasound is a promising tool able to provide direct information on soft tissue degeneration. The aim of our study was to systematically determine the site-specific diagnostic performance of semi-quantitative ultrasound grading of knee femoral articular cartilage, osteophytes and meniscal extrusion, and of radiographic assessment of joint space narrowing and osteophytes, using MRI as a reference standard. Eighty asymptomatic and 79 symptomatic subjects with mean age of 57.7 years were included in the study. Ultrasound performed best in the assessment of femoral medial and lateral osteophytes, and medial meniscal extrusion. In comparison to radiography, ultrasound performed better or at least equally well in identification of tibio-femoral osteophytes, medial meniscal extrusion and medial femoral cartilage morphological degeneration. Ultrasound provides relevant additional diagnostic information on tissue-specific morphological changes not depicted by conventional radiography. Consequently, the use of ultrasound as a complementary imaging tool along with radiography may enable more accurate and cost-effective diagnostics of knee osteoarthritis at the primary healthcare level. PMID:26926836

  15. Validation of Computed Radiography (CR) Exposure Chart for Stainless Steel and Aluminium

    International Nuclear Information System (INIS)

    Nassir, M.A.; Khairul Anuar Mohd Salleh; Arshad Yassin

    2015-01-01

    Computed radiography (CR) is a technique that is currently used to complement the conventional radiography in Non Destructive Testing (NDT). With CR, phosphorous base imaging plate (IP) is used to acquire digital radiographic images. The degree of absorption by the IP is proportional to the intensity of the dose received. The IP stores latent image which subsequently digitized by the CR reader. Prior to radiography exposure, the radiation dosage is determined by referring to the exposure chart. Exposure chart is one of the most important tools for achieving acceptable quality radiographs. Therefore, it is important to have a reliable and accurate exposure chart. The aim of this study is to test and validate exposure charts that were developed based on the statistical analysis of the digital radiographic grey values. The charts produced were for stainless steel and aluminum. According to EN 14784-2:2005, acceptable normalized signal-to-noise ratio (SNR N ) for testing class A and class B shall have minimum 70 and 120 respectively. (author)

  16. Traumatic hallux varus repair utilizing a soft-tissue anchor: a case report.

    Science.gov (United States)

    Labovitz, J M; Kaczander, B I

    2000-01-01

    Hallux varus is usually iatrogenic in nature; however, congenital and acquired etiologies have been described in the literature. The authors present a case of traumatic hallux varus secondary to rupture of the adductor tendon. Surgical correction was performed using a soft tissue anchor for maintenance of the soft tissues utilized for repair.

  17. The use of time-of-flight camera for navigating robots in computer-aided surgery: monitoring the soft tissue envelope of minimally invasive hip approach in a cadaver study.

    Science.gov (United States)

    Putzer, David; Klug, Sebastian; Moctezuma, Jose Luis; Nogler, Michael

    2014-12-01

    Time-of-flight (TOF) cameras can guide surgical robots or provide soft tissue information for augmented reality in the medical field. In this study, a method to automatically track the soft tissue envelope of a minimally invasive hip approach in a cadaver study is described. An algorithm for the TOF camera was developed and 30 measurements on 8 surgical situs (direct anterior approach) were carried out. The results were compared to a manual measurement of the soft tissue envelope. The TOF camera showed an overall recognition rate of the soft tissue envelope of 75%. On comparing the results from the algorithm with the manual measurements, a significant difference was found (P > .005). In this preliminary study, we have presented a method for automatically recognizing the soft tissue envelope of the surgical field in a real-time application. Further improvements could result in a robotic navigation device for minimally invasive hip surgery. © The Author(s) 2014.

  18. The effects of LIPUS on soft-tissue healing: a review of literature.

    Science.gov (United States)

    Khanna, Anil; Nelmes, Richard T C; Gougoulias, Nikolaos; Maffulli, Nicola; Gray, Jim

    2009-01-01

    Ultrasound is widely used for imaging purposes and as an adjunct to physiotherapy. Low-intensity pulsed ultrasound (LIPUS), having removed the thermal component found at higher intensities, is used to improve bone healing. However, its potential role in soft-tissue healing is still under investigation. We searched on Medline using the keywords: low-intensity pulsed ultrasound, LIPUS and LIPUS and soft-tissue healing. Thirty-two suitable articles were identified. Research, mainly pre-clinical, so far has shown encouraging result, with LIPUS able to promote healing in various soft tissues such as cartilage, inter-vertebral disc, etc. The effect on the bone-tendon junction, however, is primarily on bone. The role of LIPUS in treating tendinopathies is questionable. Adequately powered human studies with standardisation of intensities and dosages of LIPUS for each target tissue are needed.

  19. Comparison of soft-tissue orbital morphometry in attractive and normal Italian subjects.

    Science.gov (United States)

    Sforza, Chiarella; Dolci, Claudia; Grandi, Gaia; Tartaglia, Gianluca M; Laino, Alberto; Ferrario, Virgilio F

    2015-01-01

    To identify esthetic characteristics of the orbital soft tissues of attractive Italian adult women and men. Three-dimensional computerized digitizers were used to collect the coordinates of facial landmarks in 199 healthy, normal subjects aged 18 to 30 years (71 women, 128 men; mean age, 22 years) and in 126 coetaneous attractive subjects (92 women, 34 men; mean age, 20 years) selected during beauty competitions. From the landmarks, six linear distances, two ratios, six angles, and two areas were calculated. Attractive subjects were compared with normal ones by computing z-scores. Intercanthal width was reduced while eye fissure lengths were increased in both genders. Orbital heights (os-or) were increased only in attractive women, with a significant gender-related difference. The inclinations of the eye fissure were increased in attractive subjects, while the inclinations of the orbit were reduced. For several of the analyzed measurements, similar patterns of z-scores were observed for attractive men and women (r  =  .883). Attractive women and men had several specific esthetic characteristics in their orbital soft tissues; esthetic reference values can be used to determine optimal goals in surgical treatment.

  20. Ballistic impacts on an anatomically correct synthetic skull with a surrogate skin/soft tissue layer.

    Science.gov (United States)

    Mahoney, Peter; Carr, Debra; Arm, Richard; Gibb, Iain; Hunt, Nicholas; Delaney, Russ J

    2018-03-01

    The aim of this work was to further develop a synthetic model of ballistic head injury by the addition of skin and soft tissue layers to an anatomically correct polyurethane skull filled with gelatine 10% by mass. Six head models were impacted with 7.62 x 39 mm full metal jacket mild steel core (FMJ MSC) bullets with a mean velocity of 652 m/s. The impact events were filmed with high-speed cameras. The models were imaged pre- and post-impact using computed tomography. The models were assessed post impact by two experienced Home Office pathologists and the images assessed by an experienced military radiologist. The findings were scored against real injuries. The entry wounds, exit wounds and fracture patterns were scored positively, but the synthetic skin and soft tissue layer was felt to be too extendable. Further work is ongoing to address this.

  1. Soft tissue augmentation techniques and materials used in the oral cavity : an overview

    NARCIS (Netherlands)

    Wolff, J.; Farré-Guasch, E.; Sándor, G.K.; Gibbs, S.; Jager, D.J.; Forouzanfar, T.

    2016-01-01

    Purpose: Oral soft tissue augmentation or grafting procedures are often necessary to achieve proper wound closure after deficits resulting from tumor excision, clefts, trauma, dental implants, and tooth recessions. Materials and Methods: Autologous soft tissue grafts still remain the gold standard

  2. EPIDEMIOLOGY AND SURVIVAL OF PATIENTS WITH MALIGNANT TUMORS OF CONNECTIVE AND SOFT TISSUE

    Directory of Open Access Journals (Sweden)

    V. M. Merabishvili

    2015-01-01

    Full Text Available Introduction. Malignant tumors of connective and soft tissue are met relatively rare, although in general in Russia each year more than 1.500 new cases are registered. On five administrative territories of Russia during a year there are recorded less than 5 new cases of malignant tumors of connective and soft tissue (Yamal-Nenets A.R. – 4; Tuva Republic – 0, Magadan Region – 3; Chukotka A.R. – 0; Jewish A.R. – 4. More seldom data on these patients’ survival are published. Purpose of study. To estimate dynamics of incidence of malignant tumors of connective and soft tissue on the basis of public reporting, to calculate the index accuracy and observed and relative survival rates by histological forms, including sarcomas. Material and methods. To perform a detailed study there were selected, for two periods of observation, respectively 1054 patients (1995–2001 and 919 patients (2002–2008. Estimation of survival was carried out using software, which had been developed together with Ltd. «Novel» (Director – T.L.Tsvetkova, Ph.D.. results of study. The most typical incidence rate for of malignant tumors of connective and soft tissue (S47, 49 that are presented by  cancer registries of different countries is from 1.5 to 2.5 0/   in men and 1.5–2.0 0/   in women. Dynamics  of morbidity of the Russian population, Moscow and St. Petersburg indicates that the level of standardized  incidence rates is in the range of 2.0 0/   in men and within 1.5 0/   in women. The mortality rate in 2013  was respectively for men and women in Russia in total 1.7 0/   and 1.13 0/   , in Moscow – 1.42 0/   and  1.24 0/   , in St. Petersburg – 1.88 0/   and 1.26 0/   . The index accuracy for both sexes in Russia is 0.88,  in Moscow – 1.2; in St. Petersburg – 1.4. This index should be used for the site of these diseases with high fatality. According to official data a one-year lethality of patients with tumors of connective and soft

  3. Standard guide for computed radiography

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This guide provides general tutorial information regarding the fundamental and physical principles of computed radiography (CR), definitions and terminology required to understand the basic CR process. An introduction to some of the limitations that are typically encountered during the establishment of techniques and basic image processing methods are also provided. This guide does not provide specific techniques or acceptance criteria for specific end-user inspection applications. Information presented within this guide may be useful in conjunction with those standards of 1.2. 1.2 CR techniques for general inspection applications may be found in Practice E2033. Technical qualification attributes for CR systems may be found in Practice E2445. Criteria for classification of CR system technical performance levels may be found in Practice E2446. Reference Images Standards E2422, E2660, and E2669 contain digital reference acceptance illustrations. 1.3 The values stated in SI units are to be regarded as the st...

  4. Soft tissue Burkitt's lymphoma: radiological findings

    International Nuclear Information System (INIS)

    Garcia-Barredo, R.; Fernandez Echevarria, M.A.; Riego, M. del; Canga, A.

    1998-01-01

    An unusual case is reported of a soft tissue mass in the lower extremity, without bone involvement, in an 85-year-old woman; the histopathological diagnosis was Burkitt's lymphoma. Pertinent clinical history, histological examination, and imaging procedures allowed early diagnosis. To our knowledge, the radiological findings in Burkitt's lymphoma with this unusual clinical presentation have not been described previously. (orig.)

  5. Clinical presentation of soft-tissue infections and its management: A study of 100 cases

    Directory of Open Access Journals (Sweden)

    Baldev Singh

    2017-01-01

    Full Text Available Background: Soft-tissue infections vary widely in their nature and severity. A clear approach to the management must allow their rapid identification and treatment as they can be life-threatening. Objective: Clinical presentation of soft-tissue infections and its management. Materials and Methods: A prospective study based on 100 patients presenting with soft-tissue infections was done. All the cases of soft-tissue infections were considered irrespective of age, sex, etiological factors, or systemic disorders. The findings were evaluated regarding the pattern of soft-tissue infections in relation to age and sex, clinical presentation, complications, duration of hospital stay, management, and mortality. Results: The most commonly involved age group was in the range of 41–60 years with male predominance. Abscess formation (45% was the most common clinical presentation. Type 2 diabetes mellitus was the most common associated comorbid condition. Staphylococcus aureus was the most common culture isolate obtained. The most common complication seen was renal failure. Patients with surgical site infections had maximum duration of stay in the hospital. About 94% of the cases of soft-tissue infections were managed surgically. Mortality was mostly encountered in the cases of complications of cellulitis. Conclusion: Skin and soft-tissue infections are among the most common infections encountered by the emergency physicians. Ignorance, reluctance to treatment, economic constraints, and illiteracy delay the early detection and the initiation of proper treatment. Adequate and timely surgical intervention in most of the cases is of utmost importance to prevent the complications and reduce the mortality.

  6. Hemorrhagic lesions in soft tissue: utility and limitations of magnetic resonance

    International Nuclear Information System (INIS)

    Legorburu, A.; Oleaga, L.; Ibarra, V.; Grande, D.

    1998-01-01

    We present four patients with hemorrhagic soft tissue tumors. The diagnosis was malignant fibrous histiocytoma in three of the patients and hematoma in the fourth. We show the magnetic resonance findings in these four cases, stressing the value of this technique in the assessment of the extension of soft tissue tumors. The difficulty in differentiating tumors with bleeding, as often occurs with malignant fibrous histiocytoma, from true hematomas. (Author) 8 refs

  7. Experimental and Computational Techniques in Soft Condensed Matter Physics

    Science.gov (United States)

    Olafsen, Jeffrey

    2010-09-01

    1. Microscopy of soft materials Eric R. Weeks; 2. Computational methods to study jammed Systems Carl F. Schrek and Corey S. O'Hern; 3. Soft random solids: particulate gels, compressed emulsions and hybrid materials Anthony D. Dinsmore; 4. Langmuir monolayers Michael Dennin; 5. Computer modeling of granular rheology Leonardo E. Silbert; 6. Rheological and microrheological measurements of soft condensed matter John R. de Bruyn and Felix K. Oppong; 7. Particle-based measurement techniques for soft matter Nicholas T. Ouellette; 8. Cellular automata models of granular flow G. William Baxter; 9. Photoelastic materials Brian Utter; 10. Image acquisition and analysis in soft condensed matter Jeffrey S. Olafsen; 11. Structure and patterns in bacterial colonies Nicholas C. Darnton.

  8. Soft Tissue Masses in the Extremities: The Accuracy of an Ultrasonographic Diagnosis

    Energy Technology Data Exchange (ETDEWEB)

    An, Ji Young; Park, So Young; Park, Ji Seon; Jin, Wook; Ryu, Kyung Nam [Kyung Hee University Medical Center, Seoul (Korea, Republic of)

    2011-09-15

    We wanted to retrospectively determine the accuracy of an ultrasonographic diagnosis of superficial soft tissue masses in the extremities by using the histologic results as the reference standard. From January 2005 to June 2010, 154 patients with soft tissue masses in the extremities and who underwent ultrasonographic evaluation followed by biopsy or resection were retrospectively evaluated. The ultrasonographic and histologic diagnoses of the soft tissue masses were lipoma, ganglion cyst, hemangioma, neurogenic tumor, giant cell tumor of the tendon sheath, epidermoid cyst, fibroma, glomus tumor, Baker's cyst and neurofibromatosis. Out of 154 patients, 114 (74%) patients showed concordance between the histologic diagnosis and the ultrasonographic diagnosis, and the remaining 40 (26%) patients did not. The diagnostic accuracy of each soft tissue mass was 95% for lipoma, 83% for ganglion cyst, 75% for hemangioma, 72% for neurogenic tumor, 50% for giant cell tumor of the tendon sheath, 43% for epidermoid cyst, 33% for fibroma and 100% each for glomus tumor, fibromatosis and Baker's cyst. Aside from these tumors, there were also sarcoma, malignant melanoma, elastofibroma, Kimura disease and pilomatricoma. Among the cases that showed discordance between the histologic diagnosis and the ultrasonographic diagnosis, three of them were notable; pilomatricoma being misdiagnosed as dermatofibroma protuberans, angiolipoma being misdiagnosed as vascular leiomyoma and malignant fibrous histiocytoma being misdiagnosed as a malignant soft tissue mass. The accuracy of an ultrasonographic diagnosis for soft tissue masses in the extremities varies greatly according to each type of mass. Lipoma, ganglion cyst, hemangioma, glomus tumor, neurogenic tumor and Baker's cyst showed a relatively high rate of concordance between the ultrasonographic diagnosis and the histologic diagnosis, but epidermoid cyst and fibroma showed a relatively lower rate of concordance

  9. Polymer structure-property requirements for stereolithographic 3D printing of soft tissue engineering scaffolds.

    Science.gov (United States)

    Mondschein, Ryan J; Kanitkar, Akanksha; Williams, Christopher B; Verbridge, Scott S; Long, Timothy E

    2017-09-01

    This review highlights the synthesis, properties, and advanced applications of synthetic and natural polymers 3D printed using stereolithography for soft tissue engineering applications. Soft tissue scaffolds are of great interest due to the number of musculoskeletal, cardiovascular, and connective tissue injuries and replacements humans face each year. Accurately replacing or repairing these tissues is challenging due to the variation in size, shape, and strength of different types of soft tissue. With advancing processing techniques such as stereolithography, control of scaffold resolution down to the μm scale is achievable along with the ability to customize each fabricated scaffold to match the targeted replacement tissue. Matching the advanced manufacturing technique to polymer properties as well as maintaining the proper chemical, biological, and mechanical properties for tissue replacement is extremely challenging. This review discusses the design of polymers with tailored structure, architecture, and functionality for stereolithography, while maintaining chemical, biological, and mechanical properties to mimic a broad range of soft tissue types. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. MAXILLOFACIAL SOFT TISSUE INJURIES IN NAIROBI, KENYA

    African Journals Online (AJOL)

    2012-09-09

    Sep 9, 2012 ... Conclusion: The leading causes of MF-STIs apparently differ from those of skeletal fractures. INTRODUCTION. Maxillofacial (MF) soft tissue injuries (STIs) are often overlooked in clinical surveys compared to fractures, yet these injuries negatively impact both on function and esthetics. Previous surveys on ...

  11. Photoactivated Composite Biomaterial for Soft Tissue Restoration in Rodents and in Humans

    Science.gov (United States)

    Nahas, Zayna; Reid, Branden; Coburn, Jeannine M.; Axelman, Joyce; Chae, Jemin J.; Guo, Qiongyu; Trow, Robert; Thomas, Andrew; Hou, Zhipeng; Lichtsteiner, Serge; Sutton, Damon; Matheson, Christine; Walker, Patricia; David, Nathaniel; Mori, Susumu; Taube, Janis M.; Elisseeff, Jennifer H.

    2015-01-01

    Soft tissue reconstruction often requires multiple surgical procedures that can result in scars and disfiguration. Facial soft tissue reconstruction represents a clinical challenge because even subtle deformities can severely affect an individual’s social and psychological function. We therefore developed a biosynthetic soft tissue replacement composed of poly(ethylene glycol) (PEG) and hyaluronic acid (HA) that can be injected and photocrosslinked in situ with transdermal light exposure. Modulating the ratio of synthetic to biological polymer allowed us to tune implant elasticity and volume persistence. In a small-animal model, implanted photocrosslinked PEG-HA showed a dose-dependent relationship between increasing PEG concentration and enhanced implant volume persistence. In direct comparison with commercial HA injections, the PEG-HA implants maintained significantly greater average volumes and heights. Reversibility of the implant volume was achieved with hyaluronidase injection. Pilot clinical testing in human patients confirmed the feasibility of the transdermal photocrosslinking approach for implantation in abdomen soft tissue, although an inflammatory response was observed surrounding some of the materials. PMID:21795587

  12. Automated planning volume definition in soft-tissue sarcoma adjuvant brachytherapy

    International Nuclear Information System (INIS)

    Lee, Eva K.; Fung, Albert Y.C.; Zaider, Marco; Brooks, J. Paul

    2002-01-01

    In current practice, the planning volume for adjuvant brachytherapy treatment for soft-tissue sarcoma is either not determined a priori (in this case, seed locations are selected based on isodose curves conforming to a visual estimate of the planning volume), or it is derived via a tedious manual process. In either case, the process is subjective and time consuming, and is highly dependent on the human planner. The focus of the work described herein involves the development of an automated contouring algorithm to outline the planning volume. Such an automatic procedure will save time and provide a consistent and objective method for determining planning volumes. In addition, a definitive representation of the planning volume will allow for sophisticated brachytherapy treatment planning approaches to be applied when designing treatment plans, so as to maximize local tumour control and minimize normal tissue complications. An automated tumour volume contouring algorithm is developed utilizing computational geometry and numerical interpolation techniques in conjunction with an artificial intelligence method. The target volume is defined to be the slab of tissue r cm perpendicularly away from the curvilinear plane defined by the mesh of catheters. We assume that if adjacent catheters are over 2r cm apart, the tissue between the two catheters is part of the tumour bed. Input data consist of the digitized coordinates of the catheter positions in each of several cross-sectional slices of the tumour bed, and the estimated distance r from the catheters to the tumour surface. Mathematically, one can view the planning volume as the volume enclosed within a minimal smoothly-connected surface which contains a set of circles, each circle centred at a given catheter position in a given cross-sectional slice. The algorithm performs local interpolation on consecutive triplets of circles. The effectiveness of the algorithm is evaluated based on its performance on a collection of

  13. Automated planning volume definition in soft-tissue sarcoma adjuvant brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Eva K. [Department of Radiation Oncology, Emory University School of Medicine, Atlanta, GA (United States); School of Industrial and Systems Engineering, Georgia Institute of Technology, Atlanta, GA (United States); Fung, Albert Y.C.; Zaider, Marco [Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY (United States); Brooks, J. Paul [School of Industrial and Systems Engineering, Georgia Institute of Technology, Atlanta, GA (United States)

    2002-06-07

    In current practice, the planning volume for adjuvant brachytherapy treatment for soft-tissue sarcoma is either not determined a priori (in this case, seed locations are selected based on isodose curves conforming to a visual estimate of the planning volume), or it is derived via a tedious manual process. In either case, the process is subjective and time consuming, and is highly dependent on the human planner. The focus of the work described herein involves the development of an automated contouring algorithm to outline the planning volume. Such an automatic procedure will save time and provide a consistent and objective method for determining planning volumes. In addition, a definitive representation of the planning volume will allow for sophisticated brachytherapy treatment planning approaches to be applied when designing treatment plans, so as to maximize local tumour control and minimize normal tissue complications. An automated tumour volume contouring algorithm is developed utilizing computational geometry and numerical interpolation techniques in conjunction with an artificial intelligence method. The target volume is defined to be the slab of tissue r cm perpendicularly away from the curvilinear plane defined by the mesh of catheters. We assume that if adjacent catheters are over 2r cm apart, the tissue between the two catheters is part of the tumour bed. Input data consist of the digitized coordinates of the catheter positions in each of several cross-sectional slices of the tumour bed, and the estimated distance r from the catheters to the tumour surface. Mathematically, one can view the planning volume as the volume enclosed within a minimal smoothly-connected surface which contains a set of circles, each circle centred at a given catheter position in a given cross-sectional slice. The algorithm performs local interpolation on consecutive triplets of circles. The effectiveness of the algorithm is evaluated based on its performance on a collection of

  14. Conventional X-ray examination and computed tomography in inflammatory rheumatic diseases

    International Nuclear Information System (INIS)

    Lingg, G.

    1996-01-01

    Plain-film radiography is an important and basic element in the assessment of inflammatory rheumatic diseases. Its various uses include assessment of inflammatory osseous destruction and the activity of inflammatory changes. Furthermore, the inflammatory collateral phenomena can indicate an acute clinical phase, and the articular soft tissue swelling and tenosynovitis are shown directly and indirectly very clearly. On the other hand, high-resolution computed tomography is very capable of showing cortical structures of bone complementary to MR. In some special clinical questions and anatomical regions, especially the axial skeleton, it delivers information of high specifity, partly for definitive diagnosis and partly for planning surgical procedures. The assessment of changes in the sacroiliac joints, sternoclavicular joints and craniocervical junction are domains of computed tomography. (orig.) [de

  15. Histologic assessment of peritumoral edema in soft tissue sarcoma

    International Nuclear Information System (INIS)

    White, Lawrence M.; Wunder, Jay S.; Bell, Robert S.; O'Sullivan, Brian; Catton, Charles; Ferguson, Peter; Blackstein, Martin; Kandel, Rita A.

    2005-01-01

    Purpose: To evaluate whether satellite tumor cells can be identified histologically in the tissues surrounding a soft tissue sarcoma and whether their presence correlates with increased T 2 -weighted signal intensity on MRI. Methods and Materials: Fifteen patients with a high-grade extremity or truncal soft tissue sarcoma underwent preoperative MRI. The extent of high T 2 -weighted signal changes in the tissues surrounding tumor, thought to represent peritumoral edema/reactive changes, was determined. Twelve patients received i.v. gadolinium, and contrast enhancement was determined. All patients underwent surgical resection in the absence of preoperative chemotherapy or radiotherapy. The presence of tumor cells in the surrounding tissues was determined histologically in representative paraffin-embedded sections and correlated with the MRI findings. Results: The extent of peritumoral T 2 -weighted MRI signal changes ranged from 0 to 7.1 cm (mean, 2.5 cm); contrast enhancement ranged from 0 to 5.3 cm (mean, 1.1 cm). Sarcoma cells were identified histologically in the tissues beyond the tumor in 10 of 15 cases. In 6 cases, tumor cells were located within 1 cm of the tumor margin, and in 4 cases, malignant cells were found at a distance >1 cm and up to a maximum of 4 cm. The location of tumor cells beyond the margin did not correlate with tumor size nor did it correlate with the location or extent of peritumoral changes. Conclusion: The ability to identify tumor cells beyond the margin of a soft tissue sarcoma has important implications in planning appropriate targets for treatment. This could influence the use of new radiotherapy technologies such as intensity-modulated radiotherapy that aim to minimize treatment volumes through conformal planning

  16. Fine tuning of work practices of common radiological investigations performed using computed radiography system

    International Nuclear Information System (INIS)

    Livingstone, Roshan S.; Timothy Peace, B.S.; Sunny, S.; Victor Raj, D.

    2007-01-01

    Introduction: The advent of the computed radiography (CR) has brought about remarkable changes in the field of diagnostic radiology. A relatively large cross-section of the human population is exposed to ionizing radiation on account of common radiological investigations. This study is intended to audit radiation doses imparted to patients during common radiological investigations involving the use of CR systems. Method: The entrance surface doses (ESD) were measured using thermoluminescent dosimeters (TLD) for various radiological investigations performed using the computed radiography (CR) systems. Optimization of radiographic techniques and radiation doses was done by fine tuning the work practices. Results and conclusion: Reduction of radiation doses as high as 47% was achieved during certain investigations with the use of optimized exposure factors and fine-tuned work practices

  17. Human soft tissue analysis using x-ray or gamma-ray techniques

    International Nuclear Information System (INIS)

    Theodorakou, C; Farquharson, M J

    2008-01-01

    This topical review is intended to describe the x-ray techniques used for human soft tissue analysis. X-ray techniques have been applied to human soft tissue characterization and interesting results have been presented over the last few decades. The motivation behind such studies is to provide improved patient outcome by using the data obtained to better understand a disease process and improve diagnosis. An overview of theoretical background as well as a complete set of references is presented. For each study, a brief summary of the methodology and results is given. The x-ray techniques include x-ray diffraction, x-ray fluorescence, Compton scattering, Compton to coherent scattering ratio and attenuation measurements. The soft tissues that have been classified using x-rays or gamma rays include brain, breast, colon, fat, kidney, liver, lung, muscle, prostate, skin, thyroid and uterus. (topical review)

  18. SU-F-J-17: Patient Localization Using MRI-Guided Soft Tissue for Head-And-Neck Radiotherapy: Indication for Margin Reduction and Its Feasibility

    International Nuclear Information System (INIS)

    Qi, X; Yang, Y; Jack, N; Santhanam, A; Yang, L; Chen, A; Low, D

    2016-01-01

    Purpose: On-board MRI provides superior soft-tissue contrast, allowing patient alignment using tumor or nearby critical structures. This study aims to study H&N MRI-guided IGRT to analyze inter-fraction patient setup variations using soft-tissue targets and design appropriate CTV-to-PTV margin and clinical implication. Methods: 282 MR images for 10 H&N IMRT patients treated on a ViewRay system were retrospectively analyzed. Patients were immobilized using a thermoplastic mask on a customized headrest fitted in a radiofrequency coil and positioned to soft-tissue targets. The inter-fraction patient displacements were recorded to compute the PTV margins using the recipe: 2.5∑+0.7σ. New IMRT plans optimized on the revised PTVs were generated to evaluate the delivered dose distributions. An in-house dose deformation registration tool was used to assess the resulting dosimetric consequences when margin adaption is performed based on weekly MR images. The cumulative doses were compared to the reduced margin plans for targets and critical structures. Results: The inter-fraction displacements (and standard deviations), ∑ and σ were tabulated for MRI and compared to kVCBCT. The computed CTV-to-PTV margin was 3.5mm for soft-tissue based registration. There were minimal differences between the planned and delivered doses when comparing clinical and the PTV reduced margin plans: the paired t-tests yielded p=0.38 and 0.66 between the planned and delivered doses for the adapted margin plans for the maximum cord and mean parotid dose, respectively. Target V95 received comparable doses as planned for the reduced margin plans. Conclusion: The 0.35T MRI offers acceptable soft-tissue contrast and good spatial resolution for patient alignment and target visualization. Better tumor conspicuity from MRI allows soft-tissue based alignments with potentially improved accuracy, suggesting a benefit of margin reduction for H&N radiotherapy. The reduced margin plans (i.e., 2 mm) resulted

  19. Injection resorbable polymer shells for soft tissue augmentation

    CSIR Research Space (South Africa)

    Naidoo, Kersch

    2008-11-01

    Full Text Available CSIR researchers have developed an injectable, resorbable soft tissue bulking product that has potential applications in fields ranging from heart and recontructive surgery, to minimally invasive cosmetic surgery. Biomaterials research is very...

  20. Intelligent systems and soft computing for nuclear science and industry

    International Nuclear Information System (INIS)

    Ruan, D.; D'hondt, P.; Govaerts, P.; Kerre, E.E.

    1996-01-01

    The second international workshop on Fuzzy Logic and Intelligent Technologies in Nuclear Science (FLINS) addresses topics related to intelligent systems and soft computing for nuclear science and industry. The proceedings contain 52 papers in different fields such as radiation protection, nuclear safety (human factors and reliability), safeguards, nuclear reactor control, production processes in the fuel cycle, dismantling, waste and disposal, decision making, and nuclear reactor control. A clear link is made between theory and applications of fuzzy logic such as neural networks, expert systems, robotics, man-machine interfaces, and decision-support techniques by using modern and advanced technologies and tools. The papers are grouped in three sections. The first section (Soft computing techniques) deals with basic tools to treat fuzzy logic, neural networks, genetic algorithms, decision-making, and software used for general soft-computing aspects. The second section (Intelligent engineering systems) includes contributions on engineering problems such as knowledge-based engineering, expert systems, process control integration, diagnosis, measurements, and interpretation by soft computing. The third section (Nuclear applications) focusses on the application of soft computing and intelligent systems in nuclear science and industry

  1. Improvement of the clinical use of computed radiography for mobile chest imaging: Image quality and patient dose

    Science.gov (United States)

    Rill, Lynn Neitzey

    Chest radiography is technically difficult because of the wide variation of tissue attenuations in the chest and limitations of screen-film systems. Mobile chest radiography, performed bedside on hospital inpatients, presents additional difficulties due to geometrical and equipment limitations inherent to mobile x-ray procedures and the severity of illness in patients. Computed radiography (CR) offers a new approach for mobile chest radiography by utilizing a photostimulable phosphor. Photostimulable phosphors are more efficient in absorbing lower-energy x-rays than standard intensifying screens and overcome some image quality limitations of mobile chest imaging, particularly because of the inherent latitude. This study evaluated changes in imaging parameters for CR to take advantage of differences between CR and screen-film radiography. Two chest phantoms, made of acrylic and aluminum, simulated x-ray attenuation for average-sized and large- sized adult chests. The phantoms contained regions representing the lungs, heart and subdiaphragm. Acrylic and aluminum disks (1.9 cm diameter) were positioned in the chest regions to make signal-to-noise ratio (SNR) measurements for different combinations of imaging parameters. Disk thicknesses (contrast) were determined from disk visibility. Effective dose to the phantom was also measured for technique combinations. The results indicated that using an anti-scatter grid and lowering x- ray tube potential improved the SNR significantly; however, the dose to the phantom also increased. An evaluation was performed to examine the clinical applicability of the observed improvements in SNR. Parameter adjustments that improved phantom SNRs by more than 50% resulted in perceived image quality improvements in the lung region of clinical mobile chest radiographs. Parameters that produced smaller improvements in SNR had no apparent effect on clinical image quality. Based on this study, it is recommended that a 3:1 grid be used for

  2. Soft computing for business intelligence

    CERN Document Server

    Pérez, Rafael; Cobo, Angel; Marx, Jorge; Valdés, Ariel

    2014-01-01

    The book Soft Computing for Business Intelligence is the remarkable output of a program based on the idea of joint trans-disciplinary research as supported by the Eureka Iberoamerica Network and the University of Oldenburg. It contains twenty-seven papers allocated to three sections: Soft Computing, Business Intelligence and Knowledge Discovery, and Knowledge Management and Decision Making. Although the contents touch different domains they are similar in so far as they follow the BI principle “Observation and Analysis” while keeping a practical oriented theoretical eye on sound methodologies, like Fuzzy Logic, Compensatory Fuzzy Logic (CFL), Rough Sets and other softcomputing elements. The book tears down the traditional focus on business, and extends Business Intelligence techniques in an impressive way to a broad range of fields like medicine, environment, wind farming, social collaboration and interaction, car sharing and sustainability.

  3. A method to optimize the processing algorithm of a computed radiography system for chest radiography.

    Science.gov (United States)

    Moore, C S; Liney, G P; Beavis, A W; Saunderson, J R

    2007-09-01

    A test methodology using an anthropomorphic-equivalent chest phantom is described for the optimization of the Agfa computed radiography "MUSICA" processing algorithm for chest radiography. The contrast-to-noise ratio (CNR) in the lung, heart and diaphragm regions of the phantom, and the "system modulation transfer function" (sMTF) in the lung region, were measured using test tools embedded in the phantom. Using these parameters the MUSICA processing algorithm was optimized with respect to low-contrast detectability and spatial resolution. Two optimum "MUSICA parameter sets" were derived respectively for maximizing the CNR and sMTF in each region of the phantom. Further work is required to find the relative importance of low-contrast detectability and spatial resolution in chest images, from which the definitive optimum MUSICA parameter set can then be derived. Prior to this further work, a compromised optimum MUSICA parameter set was applied to a range of clinical images. A group of experienced image evaluators scored these images alongside images produced from the same radiographs using the MUSICA parameter set in clinical use at the time. The compromised optimum MUSICA parameter set was shown to produce measurably better images.

  4. Soft computing for fault diagnosis in power plants

    International Nuclear Information System (INIS)

    Ciftcioglu, O.; Turkcan, E.

    1998-01-01

    Considering the advancements in the AI technology, there arises a new concept known as soft computing. It can be defined as the processing of uncertain information with the AI methods, that refers to explicitly the methods using neural networks, fuzzy logic and evolutionary algorithms. In this respect, soft computing is a new dimension in information processing technology where linguistic information can also be processed in contrast with the classical stochastic and deterministic treatments of data. On one hand it can process uncertain/incomplete information and on the other hand it can deal with non-linearity of large-scale systems where uncertainty is particularly relevant with respect to linguistic information and incompleteness is related to fault tolerance in fault diagnosis. In this perspective, the potential role of soft computing in power plant operation is presented. (author)

  5. Study of the equivalent dose distribution in organs and tissues using periapical odontological radiography

    International Nuclear Information System (INIS)

    Santos, H.F.S.; Cipeli, J.F.; Fortes, M.A.B.; Federico, C.A.

    2017-01-01

    In this article presents a study of the doses obtained in periapical odontological radiography in main tissues of the head, using thermoluminescent dosemeters of type TLD-700H applied to a anthropomorphic simulator. The results indicate that the skin and salivary glands received the highest doses and the risk of calculated injury was 1.44 x 10 -6 Sv -1 per radiograph

  6. Observer training for computer-aided detection of pulmonary nodules in chest radiography

    NARCIS (Netherlands)

    de Boo, Diederick W.; van Hoorn, François; van Schuppen, Joost; Schijf, Laura; Scheerder, Maeke J.; Freling, Nicole J.; Mets, Onno; Weber, Michael; Schaefer-Prokop, Cornelia M.

    2012-01-01

    To assess whether short-term feedback helps readers to increase their performance using computer-aided detection (CAD) for nodule detection in chest radiography. The 140 CXRs (56 with a solitary CT-proven nodules and 84 negative controls) were divided into four subsets of 35; each were read in a

  7. Digital chest radiography with an amorphous silicon flat-panel-detector versus a storage-phosphor system: comparison of soft-copy images

    International Nuclear Information System (INIS)

    Lee, Hyun Ju; Im, Jung Gi; Goo, Jin Mo; Lee, Chang Hyun

    2006-01-01

    We compared the soft-copy images produced by an amorphous silicon flat-panel-detector system with the images produced by a storage-phosphor radiography system for their ability to visualize anatomic regions of the chest. Two chest radiologists independently analyzed 234 posteroanterior chest radiographs obtained from 78 patients on high-resolution liquid crystal display monitors (2560 x 2048 x 8 bits). In each patient, one radiograph was obtained with a storage-phosphor system, and two radiographs were obtained via amorphous silicon flat-panel-detector radiography with and without spatial frequency filtering. After randomizing the 234 images, the interpreters rated the visibility and radiographic quality of 11 different anatomic regions. Each image was ranked on a five-point scale (1 = not visualized, 2 = poor visualization, 3 = fair visualization, 4 = good visualization, and 5 = excellent visualization). The statistical difference between each system was determined using the Wilcoxon's signed rank test. The visibility of three anatomic regions (hilum, heart border and ribs), as determined by the chest radiologist with 14 years experience (ρ < 0.05) and the visibility of the thoracic spine, as determined by the chest radiologist with 8 years experience (ρ = 0.036), on the amorphous silicon flat-panel-detector radiography prior to spatial frequency filtering were significantly superior to that on the storage-phosphor radiography. The visibility of 11 anatomic regions, as determined by the chest radiologist with 14 years experience (ρ < 0.0001) and the visibility of five anatomic regions (unobscured lung, rib, proximal airway, thoracic spine and overall appearance), as determined by the chest radiologist with 8 years experience (ρ < 0.05), on the amorphous silicon flat-panel-detector radiography after spatial frequency filtering were significantly superior to that on the storage-phosphor radiography. The amorphous silicon flat-panel-detector system depicted the

  8. No evidence of increased risk of soft tissue sarcomas in the neighborhood of a steel foundry in Verona

    Directory of Open Access Journals (Sweden)

    Marta Benedetti

    2010-12-01

    Full Text Available The aim of the present study was to evaluate the possible association between occurrence of soft tissue sarcomas in Verona (Italy and residence near a steel foundry, whose emissions of dioxin-like compounds may be relevant. Exposure to total suspended particulate (TSP emitted from the plant as estimated by ADMS-urban dispersion model was used as an indirect index of exposure to dioxin-like compounds. Verona municipality was divided in six subareas according to the decreasing levels of estimated TSP exposure, and soft tissue sarcomas cases were mapped according to residence at time of diagnosis. Standardized incidence ratios were computed. No statistically significant departures between observed and expected cases were detected as illustrated by trend-test results.

  9. Role of Soft Computing Approaches in HealthCare Domain: A Mini Review.

    Science.gov (United States)

    Gambhir, Shalini; Malik, Sanjay Kumar; Kumar, Yugal

    2016-12-01

    In the present era, soft computing approaches play a vital role in solving the different kinds of problems and provide promising solutions. Due to popularity of soft computing approaches, these approaches have also been applied in healthcare data for effectively diagnosing the diseases and obtaining better results in comparison to traditional approaches. Soft computing approaches have the ability to adapt itself according to problem domain. Another aspect is a good balance between exploration and exploitation processes. These aspects make soft computing approaches more powerful, reliable and efficient. The above mentioned characteristics make the soft computing approaches more suitable and competent for health care data. The first objective of this review paper is to identify the various soft computing approaches which are used for diagnosing and predicting the diseases. Second objective is to identify various diseases for which these approaches are applied. Third objective is to categories the soft computing approaches for clinical support system. In literature, it is found that large number of soft computing approaches have been applied for effectively diagnosing and predicting the diseases from healthcare data. Some of these are particle swarm optimization, genetic algorithm, artificial neural network, support vector machine etc. A detailed discussion on these approaches are presented in literature section. This work summarizes various soft computing approaches used in healthcare domain in last one decade. These approaches are categorized in five different categories based on the methodology, these are classification model based system, expert system, fuzzy and neuro fuzzy system, rule based system and case based system. Lot of techniques are discussed in above mentioned categories and all discussed techniques are summarized in the form of tables also. This work also focuses on accuracy rate of soft computing technique and tabular information is provided for

  10. Subungual Hypervascular Soft Tissue Chondroma Mimicking a Glomus Tumor: A Case Report

    International Nuclear Information System (INIS)

    Park, Jong Chun; Lee, Young Hwan; Jung, Kyung Jae

    2009-01-01

    Soft tissue chondroma, or extraskeletal chondroma, is a relatively rare, benign cartilaginous tumor that occurs most frequently in the hands and feet - a subungual location is quite rare. The authors describe a subungual soft tissue chondroma in a 25-year-old man that was visualized as a hypervascular mass on color Doppler ultrasonography and initially misdiagnosed as a glomus tumor

  11. Subungual Hypervascular Soft Tissue Chondroma Mimicking a Glomus Tumor: A Case Report

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jong Chun; Lee, Young Hwan; Jung, Kyung Jae [Catholic University of Daegu, School of Medicine, Daegu (Korea, Republic of)

    2009-09-15

    Soft tissue chondroma, or extraskeletal chondroma, is a relatively rare, benign cartilaginous tumor that occurs most frequently in the hands and feet - a subungual location is quite rare. The authors describe a subungual soft tissue chondroma in a 25-year-old man that was visualized as a hypervascular mass on color Doppler ultrasonography and initially misdiagnosed as a glomus tumor

  12. Effectiveness of soft tissue diode laser in treatment of oral mucosal lesions

    Directory of Open Access Journals (Sweden)

    Amanpreet Kaur

    2017-01-01

    Full Text Available Soft tissue diode lasers are becoming popular among clinicians due to their potential value in surgical procedures providing surface sterilization, dry surgical field, and increased patient acceptance. Two patients with different soft tissue lesions were selected, and soft tissue diode laser was used for excision and wound healing was assessed by visual method with photographs. No discomfort to the patient during and after the laser procedure was observed. Inspite of using minimal local anesthesia, avoiding placement of sutures, and not prescribing any antibiotics, minimal bleeding, no edema, and good wound healing was observed. We conclude that lasers treatments can be superior to conventional approaches with regards to easy ablation, decontamination, and hemostasis, and are less painful during and after the procedure.

  13. Lasers in Esthetic Dentistry: Soft Tissue Photobiomodulation, Hard Tissue Decontamination, and Ceramics Conditioning

    Directory of Open Access Journals (Sweden)

    Karen Müller Ramalho

    2014-01-01

    Full Text Available The increasing concern and the search for conservative dental treatments have resulted in the development of several new technologies. Low and high power lasers can be cited as one of these new technologies. Low power lasers act at cellular level leading to pain reduction, modulation of inflammation, and improvement of tissue healing. High power lasers act by increasing temperature and have the potential to promote microbial reduction and ablation of hard and soft tissues. The clinical application of both low and high power lasers requires specific knowledge concerning laser interaction with biological tissues, so that the correct irradiation protocol can be established. The present case report describes the clinical steps of two metal-ceramic crowns development in a 60-year-old patient. Three different laser wavelengths were applied throughout the treatment with different purposes: Nd:YAG laser (1,064 nm for dentin decontamination, diode (660 nm for soft tissue biomodulation, and Er:YAG laser (2,940 nm for inner ceramic surface conditioning. Lasers were successfully applied in the present case report as coadjutant in the treatment. This coadjutant technology can be a potential tool to assist treatment to reach the final success.

  14. Accurate registration of peri-implant soft tissues to create an optimal emergence profile

    Directory of Open Access Journals (Sweden)

    Ibraheem Fahad Alshiddi

    2015-01-01

    Full Text Available One of the challenges in restoring anterior space with implant restoration is maintaining the natural looking of peri-implant area. This case report presents a clinical procedure to create the soft tissue emergence profile for anterior maxillary teeth. A 49-year-old male presented with missing right maxillary lateral incisor. A provisional restoration was inserted 1 week after implant placement. Area of the provisional restoration related to the gingival tissue (transmucosal area was adjusted to create an optimum emergence profile. Two months later, an indirect method was used to accurately transfer the soft peri-implant tissues to the master cast. This clinical technique minimizes surgical procedure and avoids the possibility of soft tissue collapsing that may occur during the impression procedure.

  15. Soft Tissue Masses of Hand: A Radio-Pathological Correlation

    International Nuclear Information System (INIS)

    Agarwal, Aditi; Prakash, Mahesh; Gupta, Pankaj; Tripathy, Satyaswarup; Kakkar, Nandita; Srinivasan, Radhika; Khandelwal, Niranjan

    2015-01-01

    Aim. To evaluate soft tissue masses of the hand with magnetic resonance imaging (MRI) and ultrasonography (USG) and to correlate imaging findings with pathological findings. Material and Methods. Thirty-five patients with soft tissue masses of the hand were evaluated with high resolution USG and contrast enhanced MRI of the hand, prospectively over a period of 2.5 years. The radiological diagnosis was then compared with cytology/histopathology. Results. There were a total of 19 (55%) females. The mean age was 27.45 ± 14.7 years. Majority (45%) of cases were heteroechoic. Four cases were predominantly hyperechoic. These were later diagnosed as lipomas. Four cases were anechoic (diagnosed as ganglions). Only four lesions showed hyperintense signal on T1-weighted images. Out of these, 3 were lipomas and one was cavernous haemangioma. Three lesions were hypointense on T2-weighted images. All these lesions were diagnosed as giant cell tumor of the tendon sheath. A correct diagnosis was possible on MRI in 80% of cases (n = 28). Conclusion. MRI provides specific findings for diagnosis of certain soft tissue lesions of the hand. Ultrasonography allows accurate diagnosis of hemangioma/vascular malformations. However, in most conditions, imaging findings are nonspecific and diagnosis rests on pathologic evaluation

  16. Thallium-201 scintigraphy for bone and soft tissue tumors

    Energy Technology Data Exchange (ETDEWEB)

    Tokuumi, Yuji; Tsuchiya, Hiroyuki; Sunayama, Chiaki; Matsuda, Eizo; Asada, Naohiro; Taki, Junichi; Sumiya, Hisashi; Miyauchi, Tsutomu; Tomita, Katsuro [Kanazawa Univ. (Japan). School of Medicine

    1995-05-01

    This study was undertaken to assess the usefulness of thallium-201 scintigraphy in bone and soft tissue tumors. Pre-therapy scintigraphy was undertaken in a total of 136 patients with histologically confirmed diagnosis, consisting of 74 with malignant bone and soft tissue tumors, 39 with benign ones, 12 with diseases analogous to tumors, and 11 others. Thallium activity was graded on a scale of 0-4: 0=background activity, 1=equivocal activity, 2=definitive activity, but less than myocardium, 3=definite activity equal to myocardium, and 4=activity greater than myocardium. In the group of malignant tumors, thallium-201 uptake was found in 80%, although it was low for chondrosarcoma (2/8) and malignant Schwannoma (one/3). The group of benign tumors, however, showed it in only 41%, being restricted to those with giant cell tumors, chondroblastoma, fibromatosis, and osteoid osteoma. Thallium-201 uptake was also found in all 8 patients with metastatic tumors. In 23 patients undergoing thallium imaging before and after chemotherapy, scintigraphic findings revealed a high correlation with histopathological findings. Thus, thallium-201 scintigraphy may be potentially used to distinguish malignant from benign bone and soft tissue tumors, except for a few histopathological cases, as well as to determine loco-regional metastases and response to chemotherapy. (N.K.).

  17. Single-stage soft tissue reconstruction and orbital fracture repair for complex facial injuries.

    Science.gov (United States)

    Wu, Peng Sen; Matoo, Reshvin; Sun, Hong; Song, Li Yuan; Kikkawa, Don O; Lu, Wei

    2017-02-01

    Orbital fractures with open periorbital wounds cause significant morbidity. Timing of debridement with fracture repair and soft tissue reconstruction is controversial. This study focuses on the efficacy of early single-stage repair in combined bony and soft tissue injuries. Retrospective review. Twenty-three patients with combined open soft tissue wounds and orbital fractures were studied for single-stage orbital reconstruction and periorbital soft tissue repair. Inclusion criteria were open soft tissue wounds with clinical and radiographic evidence of orbital fractures and repair performed within 48 h after injury. Surgical complications and reconstructive outcomes were assessed over 6 months. The main outcome measures were enophthalmos, pre- and post-CT imaging of orbits, scar evaluation, presence of diplopia, and eyelid position. Enophthalmos was corrected in 16/19 cases and improved in 3/19 cases. 3D reconstruction of CT images showed markedly improved orbital alignment with objective measurements of the optic foramen to cornea distance (mm) in reconstructed orbits relative to intact orbits of 0.66, 95% confidence interval [CI] (lower 0.33, upper 0.99) mm. The mean baseline of Stony Brook Scar Evaluation Scale was 0.6, 95%CI (0.30-0.92), and for 6 months, the mean score was 3.4, 95%CI (3.05-3.73). Residual diplopia in secondary gazes was present in two patients; one patient had ectropion. Complications included one case of local wound infection. An early single-stage repair of combined soft tissue and orbital fractures yields satisfactory functional and aesthetic outcomes. Complications are low and likely related to trauma severity. Copyright © 2016 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  18. Tropical pulmonary eosinophilia: a comparative evaluation of plain chest radiography and computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Sandhu Manavijit; Mukhopadhyay Sima; Sharma, S.K. [All India Inst. of Medical Sciences, New Delhi (India). Dept. of Nuclear Medicine

    1996-02-01

    Plain chest radiography and computed tomography (CT) of the chest were performed on 10 patients with tropical pulmonary eosinophilia (TPE). Chest radiographs revealed bilateral diffuse lesions in the lungs of all the patients with relative sparing of lower lobes in one patient. However, computed tomography revealed bilateral diffuse lung lesions in all of the patients with relative sparing of lower lobes in three patients. In seven (70%) of the 10 patients, CT provided additional information. Computed tomography was found to be superior for the detection of reticulonodular pattern, bronchiectasis, air trapping, calcification and mediastinal adenopathy. No correlation was found between pulmonary function and gas exchange data using CT densities. There was also no correlation between the absolute eosinophil count (AEC) and the radiological severity of lesions. In six patients, high-resolution CT (HRCT) was performed in addition to conventional CT (CCT), and nodularity of lesions was better appreciated in these patients. It is concluded from this study that CT is superior to plain radiography for the evaluation of patients with TPE. 17 refs., 2 tabs., 4 figs.

  19. Diffuse reflectance spectroscopy for optical soft tissue differentiation as remote feedback control for tissue-specific laser surgery.

    Science.gov (United States)

    Stelzle, Florian; Tangermann-Gerk, Katja; Adler, Werner; Zam, Azhar; Schmidt, Michael; Douplik, Alexandre; Nkenke, Emeka

    2010-04-01

    Laser surgery does not provide haptic feedback for operating layer-by-layer and thereby preserving vulnerable anatomical structures like nerve tissue or blood vessels. Diffuse reflectance spectra can facilitate remote optical tissue differentiation. It is the aim of the study to use this technique on soft tissue samples, to set a technological basis for a remote optical feedback system for tissue-specific laser surgery. Diffuse reflectance spectra (wavelength range: 350-650 nm) of ex vivo types of soft tissue (a total of 10,800 spectra) of the midfacial region of domestic pigs were remotely measured under reduced environmental light conditions and analyzed in order to differentiate between skin, mucosa, muscle, subcutaneous fat, and nerve tissue. We performed a principal components (PC) analysis (PCA) to reduce the number of variables. Linear discriminant analysis (LDA) was utilized for classification. For the tissue differentiation, we calculated the specificity and sensitivity by receiver operating characteristic (ROC) analysis and the area under curve (AUC). Six PCs were found to be adequate for tissue differentiation with diffuse reflectance spectra using LDA. All of the types of soft tissue could be differentiated with high specificity and sensitivity. Only the tissue pairs nervous tissue/fatty tissue and nervous tissue/mucosa showed a decline of differentiation due to bio-structural similarity. However, both of these tissue pairs could still be differentiated with a specificity and sensitivity of more than 90%. Analyzing diffuse reflectance spectroscopy with PCA and LDA allows for remote differentiation of biological tissue. Considering the limitations of the ex vivo conditions, the obtained results are promising and set a basis for the further development of a feedback system for tissue-specific laser surgery. (c) 2010 Wiley-Liss, Inc.

  20. Computers in dental radiography: a scenario for the future

    International Nuclear Information System (INIS)

    Webber, R.L.

    1985-01-01

    The recent emergence of cost-effective computing power makes it possible to integrate sophisticated data-sampling and image-interpretation techniques into dental radiography for the first time. A prototype system is being developed to permit clinical information expressed in three dimensions--plus time--to be made visible almost instantly. The associated X-ray dose for a complete three-dimensional survey of a selected dental region is predicted to be less than that required for a single conventional periapical radiograph exposed on D-speed film

  1. Imaging the hard/soft tissue interface.

    Science.gov (United States)

    Bannerman, Alistair; Paxton, Jennifer Z; Grover, Liam M

    2014-03-01

    Interfaces between different tissues play an essential role in the biomechanics of native tissues and their recapitulation is now recognized as critical to function. As a consequence, imaging the hard/soft tissue interface has become increasingly important in the area of tissue engineering. Particularly as several biotechnology based products have made it onto the market or are close to human trials and an understanding of their function and development is essential. A range of imaging modalities have been developed that allow a wealth of information on the morphological and physical properties of samples to be obtained non-destructively in vivo or via destructive means. This review summarizes the use of a selection of imaging modalities on interfaces to date considering the strengths and weaknesses of each. We will also consider techniques which have not yet been utilized to their full potential or are likely to play a role in future work in the area.

  2. SU-F-P-06: Moving From Computed Radiography to Digital Radiography: A Collaborative Approach to Improve Image Quality

    Energy Technology Data Exchange (ETDEWEB)

    Sandoval, D; Mlady, G; Selwyn, R [University of New Mexico School of Medicine, Albuquerque, NM (United States); Valenti, D; Bateman, T; Norris, V [University of New Mexico Hospital, Albuquerque, New Mexico (United States)

    2016-06-15

    Purpose: To bring together radiologists, technologists, and physicists to utilize post-processing techniques in digital radiography (DR) in order to optimize image acquisition and improve image quality. Methods: Sub-optimal images acquired on a new General Electric (GE) DR system were flagged for follow-up by radiologists and reviewed by technologists and medical physicists. Various exam types from adult musculoskeletal (n=35), adult chest (n=4), and pediatric (n=7) were chosen for review. 673 total images were reviewed. These images were processed using five customized algorithms provided by GE. An image score sheet was created allowing the radiologist to assign a numeric score to each of the processed images, this allowed for objective comparison to the original images. Each image was scored based on seven properties: 1) overall image look, 2) soft tissue contrast, 3) high contrast, 4) latitude, 5) tissue equalization, 6) edge enhancement, 7) visualization of structures. Additional space allowed for additional comments not captured in scoring categories. Radiologists scored the images from 1 – 10 with 1 being non-diagnostic quality and 10 being superior diagnostic quality. Scores for each custom algorithm for each image set were summed. The algorithm with the highest score for each image set was then set as the default processing. Results: Images placed into the PACS “QC folder” for image processing reasons decreased. Feedback from radiologists was, overall, that image quality for these studies had improved. All default processing for these image types was changed to the new algorithm. Conclusion: This work is an example of the collaboration between radiologists, technologists, and physicists at the University of New Mexico to add value to the radiology department. The significant amount of work required to prepare the processing algorithms, reprocessing and scoring of the images was eagerly taken on by all team members in order to produce better quality

  3. SU-F-P-06: Moving From Computed Radiography to Digital Radiography: A Collaborative Approach to Improve Image Quality

    International Nuclear Information System (INIS)

    Sandoval, D; Mlady, G; Selwyn, R; Valenti, D; Bateman, T; Norris, V

    2016-01-01

    Purpose: To bring together radiologists, technologists, and physicists to utilize post-processing techniques in digital radiography (DR) in order to optimize image acquisition and improve image quality. Methods: Sub-optimal images acquired on a new General Electric (GE) DR system were flagged for follow-up by radiologists and reviewed by technologists and medical physicists. Various exam types from adult musculoskeletal (n=35), adult chest (n=4), and pediatric (n=7) were chosen for review. 673 total images were reviewed. These images were processed using five customized algorithms provided by GE. An image score sheet was created allowing the radiologist to assign a numeric score to each of the processed images, this allowed for objective comparison to the original images. Each image was scored based on seven properties: 1) overall image look, 2) soft tissue contrast, 3) high contrast, 4) latitude, 5) tissue equalization, 6) edge enhancement, 7) visualization of structures. Additional space allowed for additional comments not captured in scoring categories. Radiologists scored the images from 1 – 10 with 1 being non-diagnostic quality and 10 being superior diagnostic quality. Scores for each custom algorithm for each image set were summed. The algorithm with the highest score for each image set was then set as the default processing. Results: Images placed into the PACS “QC folder” for image processing reasons decreased. Feedback from radiologists was, overall, that image quality for these studies had improved. All default processing for these image types was changed to the new algorithm. Conclusion: This work is an example of the collaboration between radiologists, technologists, and physicists at the University of New Mexico to add value to the radiology department. The significant amount of work required to prepare the processing algorithms, reprocessing and scoring of the images was eagerly taken on by all team members in order to produce better quality

  4. Electron probe microanalysis for clinical investigations: Microdrop and soft tissue analysis

    International Nuclear Information System (INIS)

    Ingram, M.J.; Ingram, F.D.

    1984-01-01

    The most important advantage offered by electron probe microanalysis (EPA) for clinical investigations is the ability to analyze smaller volumes of tissue than is possible with conventional techniques. The sample can be a biological soft tissue specimen, which involves subcellular localization, or a picoliter fluid droplet. In either case, the analysis can be nondestructive and permit multiple analyses for a number of elements in a given sample. The most highly developed electron microprobe analytical technique is fluid drop analysis, popularly referred to as microdrop analysis. This method provides the investigator with an analytic capability that has an accuracy of measurement often 1% or better on 20 to 30 picoliter fluid droplets. Electron microprobe techniques have been used for studies of animal hard tissue and for studies that involve insoluble inclusions. However, the development of techniques for studies of labile constituents in animal soft tissue has been much slower. It has been necessary not only to develop appropriate methods of tissue preparation, but also to establish sound techniques for tissue collection. Although there are adequate methods for collection of most types of tissue from laboratory animals, many of these methods are not suitable for human subjects. In order to provide the reader with a better understanding of the capabilities and potential for the application of electron microprobe methodology to problems in clinical medicine, the authors discuss some of their experiences with liquid droplet analysis and quantitative electrolyte distribution measurements in animal soft tissue

  5. Surgical considerations when reporting MRI studies of soft tissue sarcoma of the limbs

    Energy Technology Data Exchange (ETDEWEB)

    De la Hoz Polo, Marcela [Kings College Hospital, Radiology Department, London, Brixton (United Kingdom); Dick, Elizabeth [St Mary' s Hospital, Imperial College Healthcare NHS Trust, Radiology Department, London (United Kingdom); Bhumbra, Rej [Newham and The Royal London Hospitals, Trauma and Orthopaedic Department, Barts Health Orthopaedic Centre, London, Whitechapel (United Kingdom); Pollock, Rob [Royal National Orthopaedic Hospital, Trauma and Orthopaedic Department, Stanmore (United Kingdom); Sandhu, Ranbir [University Hospitals Birmingham, Radiology Department, Queen Elizabeth Hospital, Birmingham (United Kingdom); Saifuddin, Asif [Royal National Orthopaedic Hospital, Radiology Department, Stanmore (United Kingdom)

    2017-12-15

    Soft tissue sarcomas (STS) are rare tumours that require prompt diagnosis and treatment at a specialist centre. Magnetic resonance imaging (MRI) has become the modality of choice for identification, characterisation, biopsy planning and staging of soft tissue masses. MRI enables both the operating surgeon and patient to be optimally prepared prior to surgery for the likelihood of margin-negative resection and to anticipate possible sacrifice of adjacent structures and consequent loss of function. The aim of this review is to aid the radiologist in performing and reporting MRI studies of soft tissue sarcomas, with particular reference to the requirements of the surgical oncologist. (orig.)

  6. Nonsurgical management of soft tissue around the restorations of maxillary anterior implants: a clinical report

    Directory of Open Access Journals (Sweden)

    Seyedan K

    2010-01-01

    Full Text Available "nBackground and Aims: Soft tissue management with providing the esthetic for restoration of a single implant in the anterior maxilla is of great importance. Tissue training helps to develop a proper emergence profile and natural tooth appearance. The aim of this article was to report a nonsurgical management of undesirable contours of soft tissue around maxillary anterior implants to achieve an optimum appearance. "nMaterials and Methods: A 23-year-old female with congenital missing of maxillary lateral incisors, after completion of a fixed orthodontic treatment and gain enough space, received 2 dental implants. After second phase surgery and healing period, construction of the restorations was not possible through conventional method because of severe soft tissue collapse. In this case, soft tissue contours were corrected using a provisional restoration and then final restoration was made and delivered. "nConclusion: Tissue training with a provisional restoration helps to re-establish normal gingival tissue contours and interdental papillae around the restoration of maxillary anterior implants.

  7. Intramodality and intermodality agreement in radiography and computed tomography of equine distal limb fractures.

    Science.gov (United States)

    Crijns, C P; Martens, A; Bergman, H-J; van der Veen, H; Duchateau, L; van Bree, H J J; Gielen, I M V L

    2014-01-01

    Computed tomography (CT) is increasingly accessible in equine referral hospitals. To document the level of agreement within and between radiography and CT in characterising equine distal limb fractures. Retrospective descriptive study. Images from horses that underwent radiographic and CT evaluation for suspected distal limb fractures were reviewed, including 27 horses and 3 negative controls. Using Cohen's kappa and weighted kappa analysis, the level of agreement among 4 observers for a predefined set of diagnostic characteristics for radiography and CT separately and for the level of agreement between the 2 imaging modalities were documented. Both CT and radiography had very good intramodality agreement in identifying fractures, but intermodality agreement was lower. There was good intermodality and intramodality agreement for anatomical localisation and the identification of fracture displacement. Agreement for articular involvement, fracture comminution and fracture fragment number was towards the lower limit of good agreement. There was poor to fair intermodality agreement regarding fracture orientation, fracture width and coalescing cracks; intramodality agreement was higher for CT than for radiography for these features. Further studies, including comparisons with surgical and/or post mortem findings, are required to determine the sensitivity and specificity of CT and radiography in the diagnosis and characterisation of equine distal limb fractures. © 2013 EVJ Ltd.

  8. Real-time simulation of contact and cutting of heterogeneous soft-tissues.

    Science.gov (United States)

    Courtecuisse, Hadrien; Allard, Jérémie; Kerfriden, Pierre; Bordas, Stéphane P A; Cotin, Stéphane; Duriez, Christian

    2014-02-01

    This paper presents a numerical method for interactive (real-time) simulations, which considerably improves the accuracy of the response of heterogeneous soft-tissue models undergoing contact, cutting and other topological changes. We provide an integrated methodology able to deal both with the ill-conditioning issues associated with material heterogeneities, contact boundary conditions which are one of the main sources of inaccuracies, and cutting which is one of the most challenging issues in interactive simulations. Our approach is based on an implicit time integration of a non-linear finite element model. To enable real-time computations, we propose a new preconditioning technique, based on an asynchronous update at low frequency. The preconditioner is not only used to improve the computation of the deformation of the tissues, but also to simulate the contact response of homogeneous and heterogeneous bodies with the same accuracy. We also address the problem of cutting the heterogeneous structures and propose a method to update the preconditioner according to the topological modifications. Finally, we apply our approach to three challenging demonstrators: (i) a simulation of cataract surgery (ii) a simulation of laparoscopic hepatectomy (iii) a brain tumor surgery. Copyright © 2013 Elsevier B.V. All rights reserved.

  9. Soft tissue augmentation - Use of hyaluronic acid as dermal filler

    Directory of Open Access Journals (Sweden)

    Vedamurthy Maya

    2004-11-01

    Full Text Available Soft tissue augmentation has revolutionized the treatment of the aging face. It is a technique in which a substance is injected under the skin. The concept of utilizing materials for soft tissue augmentation actually began around 1950 with the use of fluid silicone. Today we have a large armamentarium of implant materials to delay the tell tale signs of aging. Filling has replaced conventional surgery in facial rejuvenation. In this article, the emphasis will be on hyaluronic acid as this substance is easily available in India and ranks among the most widely used dermal fillers.

  10. Soft tissue augmentation - Use of hyaluronic acid as dermal filler

    Directory of Open Access Journals (Sweden)

    Vedamurthy Maya

    2004-01-01

    Full Text Available Soft tissue augmentation has revolutionized the treatment of the aging face. It is a technique in which a substance is injected under the skin. The concept of utilizing materials for soft tissue augmentation actually began around 1950 with the use of fluid silicone. Today we have a large armamentarium of implant materials to delay the tell tale signs of aging. Filling has replaced conventional surgery in facial rejuvenation. In this article, the emphasis will be on hyaluronic acid as this substance is easily available in India and ranks among the most widely used dermal fillers.

  11. Necrotizing Soft Tissue Infection Occurring after Exposure to Mycobacterium marinum

    Directory of Open Access Journals (Sweden)

    Shivani S. Patel

    2014-01-01

    Full Text Available Cutaneous infections caused by Mycobacterium marinum have been attributed to aquarium or fish exposure after a break in the skin barrier. In most instances, the upper limbs and fingers account for a majority of the infection sites. While previous cases of necrotizing soft tissue infections related to M. marinum have been documented, the importance of our presenting case is to illustrate the aggressive nature of M. marinum resulting in a persistent necrotizing soft tissue infection of a finger that required multiple aggressive wound debridements, followed by an amputation of the affected extremity, in order to hasten recovery.

  12. Soft-tissue imaging with C-arm cone-beam CT using statistical reconstruction

    International Nuclear Information System (INIS)

    Wang, Adam S; Stayman, J Webster; Otake, Yoshito; Siewerdsen, Jeffrey H; Kleinszig, Gerhard; Vogt, Sebastian; Gallia, Gary L; Khanna, A Jay

    2014-01-01

    The potential for statistical image reconstruction methods such as penalized-likelihood (PL) to improve C-arm cone-beam CT (CBCT) soft-tissue visualization for intraoperative imaging over conventional filtered backprojection (FBP) is assessed in this work by making a fair comparison in relation to soft-tissue performance. A prototype mobile C-arm was used to scan anthropomorphic head and abdomen phantoms as well as a cadaveric torso at doses substantially lower than typical values in diagnostic CT, and the effects of dose reduction via tube current reduction and sparse sampling were also compared. Matched spatial resolution between PL and FBP was determined by the edge spread function of low-contrast (∼40–80 HU) spheres in the phantoms, which were representative of soft-tissue imaging tasks. PL using the non-quadratic Huber penalty was found to substantially reduce noise relative to FBP, especially at lower spatial resolution where PL provides a contrast-to-noise ratio increase up to 1.4–2.2× over FBP at 50% dose reduction across all objects. Comparison of sampling strategies indicates that soft-tissue imaging benefits from fully sampled acquisitions at dose above ∼1.7 mGy and benefits from 50% sparsity at dose below ∼1.0 mGy. Therefore, an appropriate sampling strategy along with the improved low-contrast visualization offered by statistical reconstruction demonstrates the potential for extending intraoperative C-arm CBCT to applications in soft-tissue interventions in neurosurgery as well as thoracic and abdominal surgeries by overcoming conventional tradeoffs in noise, spatial resolution, and dose. (paper)

  13. Comparing the 810nm diode laser with conventional surgery in orthodontic soft tissue procedures.

    Science.gov (United States)

    Ize-Iyamu, I N; Saheeb, B D; Edetanlen, B E

    2013-09-01

    To compare the use of the 810nm diode laser with conventional surgery in the management of soft tissue mucogingival problems associated with orthodontic treatment. Orthodontic patients requiring different soft tissue surgical procedures were randomly assigned to receive conventional surgery or soft tissue diode laser, (wavelength 810 nm). Parameters documented include the type of anaesthesia used, intra and post operative pain, bleeding, the use of scalpel and sutures. The chi-squared test was used to test for significance at 95% confidence level. Probability values (p-values) less than 0.05 were regarded as significant. Only 2(16.7%) of the procedures carried out with the soft tissue laser required infiltration anaesthesia compared to 10 (90.9%) with conventional surgery and this was significant (Pdiode laser (Pdiode laser. No sutures were used in all soft tissue cases managed with the diode laser and this was significant (Plaser compared with conventional surgery. Orthodontic patients treated with the diode laser required less infiltration anaesthesia, had reduced bleeding during and after surgery, rapid postoperative haemostasis, elimination of the need for sutures and an improved postoperative comfort and healing.

  14. RNA secondary structure prediction using soft computing.

    Science.gov (United States)

    Ray, Shubhra Sankar; Pal, Sankar K

    2013-01-01

    Prediction of RNA structure is invaluable in creating new drugs and understanding genetic diseases. Several deterministic algorithms and soft computing-based techniques have been developed for more than a decade to determine the structure from a known RNA sequence. Soft computing gained importance with the need to get approximate solutions for RNA sequences by considering the issues related with kinetic effects, cotranscriptional folding, and estimation of certain energy parameters. A brief description of some of the soft computing-based techniques, developed for RNA secondary structure prediction, is presented along with their relevance. The basic concepts of RNA and its different structural elements like helix, bulge, hairpin loop, internal loop, and multiloop are described. These are followed by different methodologies, employing genetic algorithms, artificial neural networks, and fuzzy logic. The role of various metaheuristics, like simulated annealing, particle swarm optimization, ant colony optimization, and tabu search is also discussed. A relative comparison among different techniques, in predicting 12 known RNA secondary structures, is presented, as an example. Future challenging issues are then mentioned.

  15. Dose equivalent near the bone-soft tissue interface from nuclear fragments produced by high-energy protons

    Science.gov (United States)

    Shavers, M. R.; Poston, J. W.; Cucinotta, F. A.; Wilson, J. W.

    1996-01-01

    During manned space missions, high-energy nucleons of cosmic and solar origin collide with atomic nuclei of the human body and produce a broad linear energy transfer spectrum of secondary particles, called target fragments. These nuclear fragments are often more biologically harmful than the direct ionization of the incident nucleon. That these secondary particles increase tissue absorbed dose in regions adjacent to the bone-soft tissue interface was demonstrated in a previous publication. To assess radiological risks to tissue near the bone-soft tissue interface, a computer transport model for nuclear fragments produced by high energy nucleons was used in this study to calculate integral linear energy transfer spectra and dose equivalents resulting from nuclear collisions of 1-GeV protons transversing bone and red bone marrow. In terms of dose equivalent averaged over trabecular bone marrow, target fragments emitted from interactions in both tissues are predicted to be at least as important as the direct ionization of the primary protons-twice as important, if recently recommended radiation weighting factors and "worst-case" geometry are used. The use of conventional dosimetry (absorbed dose weighted by aa linear energy transfer-dependent quality factor) as an appropriate framework for predicting risk from low fluences of high-linear energy transfer target fragments is discussed.

  16. ORIGINAL ARTICLES Staphylococcus aureus skin and soft-tissue ...

    African Journals Online (AJOL)

    (MRSA) has become a key pathogen in skin and soft-tissue infections. (SSTIs). The emergence of ..... SSTI isolates; (iii) improved hospital infection control guidelines and practices to prevent .... So exposed in the field. And he'll never run off ...

  17. Mathematical models of soft tissue injury repair : towards understanding musculoskeletal disorders

    OpenAIRE

    Dunster, Joanne L.

    2012-01-01

    The process of soft tissue injury repair at the cellular lew I can be decomposed into three phases: acute inflammation including coagulation, proliferation and remodelling. While the later phases are well understood the early phase is less so. We produce a series of new mathematical models for the early phases coagulation and inflammation. The models produced are relevant not only to soft tissue injury repair but also to the many disease states in which coagulation and inflammation play a rol...

  18. Soft tissue reconstruction for calcaneal fractures or osteomyelitis.

    Science.gov (United States)

    Attinger, C; Cooper, P

    2001-01-01

    A systematic approach of the surgical management of a calcaneal fracture can minimize the potential of soft tissue complications. When reducing a closed calcaneal fracture, the incision used affects the postoperative complications. The L-shaped incision with the horizontal limb lying on the lateral glabrous junction ensures maximum blood flow to either side of the incision. Whether or not the wound can be closed primarily depends on the preexisting edema, the lost calcaneal height, and the delay between the fracture and reduction (Fig. 20). The wrinkle test is a good indicator that the incision can be closed primarily if the amount of height restored is minimal. If the edema is too great, steps should be taken to reduce it sufficiently to allow successful wound closure. If the wound, after reduction, is too wide to allow primary closure, an ADM flap laterally or an AHM flap medially should be used. For larger defects, a free flap should be considered. The three important steps to reconstruction of soft tissue defects around the calcaneus include good blood supply, a infection-free wound, and the simplest soft tissue reconstructive option that covers the wound successfully. Adequate blood supply can be determined by the use of Doppler. If the supply is inadequate, revascularization is necessary before proceeding. Achieving a clean wound requires aggressive debridement, intravenous antibiotics, and good wound care. Adjuncts that can help in achieving a clean wound include topical antibiotics (silver sulfadiazine), the VAC, and hyperbaric oxygen. Osteomyelitis has to be treated aggressively. Any suspicious bone has to be removed. Only clean, healthy, bleeding bone is left behind. Antibiotic beads can be useful when there is doubt as to whether the cancellous bone is infection-free. The beads are not a substitute for good debridement, however. Soft tissue reconstruction ranges from delayed primary closure to the use of microsurgical free flaps (Fig. 21). When bone or

  19. Analysis of edentulous maxillae using computed tomography and panoramic radiography in the surgical planning of dental implants

    International Nuclear Information System (INIS)

    Sahuinco, Humberto Lazaro Choquepuma; Souza, Ricardo Pires de

    2006-01-01

    Objective: to determine agreement of three observers on analysis of linear measurements of edentulous maxillae using computed tomography and panoramic radiography in the surgical planning of dental implants. Material and Method: the samples of 17 patients were analyzed with computed tomography and panoramic radiography. Linear measurements obtained from both methods were made at the following anatomical points: left tuberosity, left canine pillar, incisive foramen, right canine pillar and right tuberosity. Kendall's W test was applied to assess the level of agreement. Results: measured W-values from the samples of the anatomical points mentioned above, analyzed with panoramic radiography and computed tomography, were: 0.75 and 0.901; 0.916 and 0.956; 0.843 and 0.964; 0.963 and 0.931; 0.95 and 0.89 respectively. Statistical analysis showed that there was no statistically significant difference. Conclusion: agreement occurred in the measurements of variables.That means that if the three observers were to select an implant to be placed in each of the anatomical regions studied, there would be a good chance whey would choose the same type. (author)

  20. Daily quality control in computed radiography mammography using the manufacturer phantom

    International Nuclear Information System (INIS)

    Jakubiak, Rosangela R.; Messias, Pricila C.; Oliveira, Carlla M.

    2011-01-01

    The quality control (QC) in mammography system involves a large amount of test tools, which implies a large space for storage and a high number of exposure. This work describes a QC system using a phantom, Fuji Computed Radiography (FCR) One Shot Phantom M Plus, that evaluates several parameters with just one exposure. The software offers tests with annual, semi-annual, quarterly, weekly and daily periodicity, and analyzes the conformities of the mammography equipment, image plate and cassettes. Because of the high number of tests, it was evaluated the daily test only for seven months in two mammography equipment. The test, through the software and its image, allows the analysis of ten parameters in QC. The evaluation of these parameters was realized by the average of the values provided by the software. Only one of the evaluated items showed not conformity, but this was observed and the necessary corrections were realized. The monitoring of use of FCR Mammography QC software with the FCR One Shot Phantom M Plus was realized and through this we could investigate that the quality program provided by the system is appropriate for the radiology services that has the Fuji Computed Radiography system. (author)

  1. Trochanteric Soft Tissue Thickness and Hip Fracture in Older Men

    OpenAIRE

    Nielson, Carrie M.; Bouxsein, Mary L.; Freitas, Sinara S.; Ensrud, Kristine E.; Orwoll, Eric S.

    2009-01-01

    Background: Greater thickness of the tissue extending laterally from the greater trochanter has been associated with a lower risk of hip fracture in women. The effect of trochanteric soft tissue thickness on the risk of incident hip fracture has not been evaluated in men.

  2. Photoacoustic imaging in both soft and hard biological tissue

    International Nuclear Information System (INIS)

    Li, T; Dewhurst, R J

    2010-01-01

    To date, most Photoacoustic (PA) imaging results have been from soft biotissues. In this study, a PA imaging system with a near-infrared pulsed laser source has been applied to obtain 2-D and 3-D images from both soft tissue and post-mortem dental samples. Imaging results showed that the PA technique has the potential to image human oral disease, such as early-stage teeth decay. For non-invasive photoacoustic imaging, the induced temperature and pressure rises within biotissues should not cause physical damage to the tissue. Several simulations based on the thermoelastic effect have been applied to predict initial temperature and pressure fields within a tooth sample. Predicted initial temperature and pressure rises are below corresponding safety limits.

  3. Computer-aided diagnosis of pulmonary diseases using x-ray darkfield radiography

    DEFF Research Database (Denmark)

    Einarsdottir, Hildur; Yaroshenko, Andre; Velroyen, Astrid

    2015-01-01

    In this work we develop a computer-aided diagnosis (CAD) scheme for classification of pulmonary disease for grating-based x-ray radiography. In addition to conventional transmission radiography, the grating-based technique provides a dark-field imaging modality, which utilizes the scattering...... properties of the x-rays. This modality has shown great potential for diagnosing early stage emphysema and fibrosis in mouse lungs in vivo. The CAD scheme is developed to assist radiologists and other medical experts to develop new diagnostic methods when evaluating grating-based images. The scheme consists...... of three stages: (i) automatic lung segmentation; (ii) feature extraction from lung shape and dark-field image intensities; (iii) classification between healthy, emphysema and fibrosis lungs. A study of 102 mice was conducted with 34 healthy, 52 emphysema and 16 fibrosis subjects. Each image was manually...

  4. Comparisons of Soft Tissue Thickness Measurements in Adult Patients With Various Vertical Patterns

    Directory of Open Access Journals (Sweden)

    Neslihan Seyhan Cezairli

    2017-08-01

    Full Text Available Objective: The purposes of this study were to evaluate to study soft tissue facial profile among the different vertical patterns using the Holdaway analysis and the soft tissue thickness measurements. Materials and Methods: The study sample consisted of 90 patients divided into 3 groups: low angle group (30 patients; mean age, 20.38±3.76 years, normal angle group (30 patients; mean age, 19.36±2.83 years and high angle group (30 patients; mean age, 19.44±2.14 years. The study sample, comprised a total of 90 patients (54 women and 36 men divided into low-angle, normal-angle and high angle groups based on vertical growth pattern using the SN/GoGn angle (high-angle group >37°; low-angle group <27°; and control group or normal angle group 27-37°. Facial soft-tissue thickness and Holdaway measurements were analyzed on each radiograph with Image J programme. One-way analysis of variance and post-hoc test (Tukey were used to compare Holdaway measurements and soft tissue thicknesses among the three groups. Results: Significant differences among vertical patterns were observed for the ‘gnathion’, ‘menton’, ‘stomion’ and ‘inferior sulcus to H line’ when both genders were combined. These measurements were thinner in the high-angle group. Significant differences among vertical patterns were observed for ‘gnathion’ and ‘lower lip to H line’ in women; for ‘stomion’ and ‘nose prominence’ in men when examined separately. Conclusion: Facial soft tissue measurements except some for in high angle group were thinner than in low angle group. All soft tissue measurements were greater except for gnathion in low angle group in men than in women.

  5. Prevalence of Malignant Soft Tissue Tumors inExtremities: An Epidemiological Study in Syria

    Directory of Open Access Journals (Sweden)

    Habib Reshadi

    2014-06-01

    Full Text Available Background:   Although the majority of soft tissue masses are benign, it is important to consider malignancy in differential diagnoses. Because most soft tissue sarcomas present as a painless mass, clinicians must watch for signs suggestive of malignancy, including large size, rapid growth, and site deep into the deep fascia.The purpose of this study was to determine the relative prevalence according to sex and age, site of tumor, skeletal distribution, and treatment (surgery, chemotherapy and radiotherapy before and after surgery, and ascertain the relative frequency of these tumors in specific anatomic sites and age groups based on pathological studies. Methods: A total of 308 patients, with a musculoskeletal tumor were evaluated retrospectively. All of the patients enrolled into this study were referred to the Beirouni Hospital of Damascus University with a proven diagnosis of alignant soft tissue tumors from the beginning of January 2008 until the end of 2010. The prevalence of the malignant soft tissue tumors in these patients was analyzed. For purposes of analysis, all lesions were placed in 1 of 9 categories: hand and wrist, forearm, humorous (arm, proximal limb girdle (axilla and shoulder, foot and ankle, thigh, hip and buttocks region, trunk, and other lesions. Age and sex also were recorded. Results: Malignant tumors consisted of seven diagnostic categories: malignant fibrous histiocytoma (23%, liposarcoma (22%, rhabdomyosarcoma (9%, leiomyosarcoma (8%, malignant schwannoma (5%, dermatofibrosarcoma protuberans (5%, synovial sarcoma (10%, fibrosarcoma (13%, extraskeletal chondrosarcoma (1%, and extraskeletal Ewing sarcoma (4%. Conclusions: Despite the multitude of pathologic possibilities, most malignant soft-tissue tumors are classified into a small number of diagnoses. These may be further defined when the site of the lesion and the age of the patient are considered. Knowledge of tumor prevalence will assist radiologists in

  6. Prevalence of Malignant Soft Tissue Tumors inExtremities: An Epidemiological Study in Syria

    Directory of Open Access Journals (Sweden)

    Habib Reshadi

    2014-06-01

    Full Text Available Background:   Although the majority of soft tissue masses are benign, it is important to consider malignancy in differential diagnoses. Because most soft tissue sarcomas present as a painless mass, clinicians must watch for signs suggestive of malignancy, including large size, rapid growth, and site deep into the deep fascia.The purpose of this study was to determine the relative prevalence according to sex and age, site of tumor, skeletal distribution, and treatment (surgery, chemotherapy and radiotherapy before and after surgery, and ascertain the relative frequency of these tumors in specific anatomic sites and age groups based on pathological studies. Methods: A total of 308 patients, with a musculoskeletal tumor were evaluated retrospectively. All of the patients enrolled into this study were referred to the Beirouni Hospital of Damascus University with a proven diagnosis of alignant soft tissue tumors from the beginning of January 2008 until the end of 2010. The prevalence of the malignant soft tissue tumors in these patients was analyzed. For purposes of analysis, all lesions were placed in 1 of 9 categories: hand and wrist, forearm, humorous (arm, proximal limb girdle (axilla and shoulder, foot and ankle, thigh, hip and buttocks region, trunk, and other lesions. Age and sex also were recorded. Results: Malignant tumors consisted of seven diagnostic categories: malignant fibrous histiocytoma (23%, liposarcoma (22%, rhabdomyosarcoma (9%, leiomyosarcoma (8%, malignant schwannoma (5%, dermatofibrosarcoma protuberans (5%, synovial sarcoma (10%, fibrosarcoma (13%, extraskeletal chondrosarcoma (1%, and extraskeletal Ewing sarcoma (4%. Conclusions: Despite the multitude of pathologic possibilities, most malignant soft-tissue tumors are classified into a small number of diagnoses. These may be further defined when the site of the lesion and the age of the patient are considered. Knowledge of tumor prevalence will assist radiologists in

  7. Soft tissue recurrence of giant cell tumor of the bone: Prevalence and radiographic features

    Directory of Open Access Journals (Sweden)

    Leilei Xu

    2017-11-01

    Full Text Available Aim: Recurrence of giant cell tumor of bone (GCTB in the soft tissue is rarely seen in the clinical practice. This study aims to determine the prevalence of soft tissue recurrence of GCTB, and to characterize its radiographic features. Methods: A total of 291 patients treated by intralesional curettage for histologically diagnosed GCTB were reviewed. 6 patients were identified to have the recurrence of GCTB in the soft tissue, all of whom had undergone marginal resection of the lesion. Based on the x-ray, CT and MRI imaging, the radiographic features of soft tissue recurrence were classified into 3 types. Type I was defined as soft tissue recurrence with peripheral ossification, type II was defined as soft tissue recurrence with central ossification, and type III was defined as pure soft tissue recurrence without ossification. Demographic data including period of recurrence and follow-up duration after the second surgery were recorded for these 6 patients. Musculoskeletal Tumor Society (MSTS scoring system was used to evaluate functional outcomes. Results: The overall recurrence rate was 2.1% (6/291. The mean interval between initial surgery and recurrence was 11.3 ± 4.1 months (range, 5–17. The recurrence lesions were located in the thigh of 2 patients, in the forearm of 2 patients and in the leg of the other 2 patients. According to the classification system mentioned above, 2 patients were classified with type I, 1 as type II and 3 as type III. After the marginal excision surgery, all patients were consistently followed up for a mean period of 13.4 ± 5.3 months (range, 6–19, with no recurrence observed at the final visit. All the patients were satisfied with the surgical outcome. According to the MSTS scale, the mean postoperative functional score was 28.0 ± 1.2 (range, 26–29. Conclusions: The classification of soft tissue recurrence of GCTB may be helpful for the surgeon to select the appropriate imaging procedure to

  8. Pitfalls in soft tissue sarcoma imaging: chronic expanding hematomas.

    Science.gov (United States)

    Jahed, Kiarash; Khazai, Behnaz; Umpierrez, Monica; Subhawong, Ty K; Singer, Adam D

    2018-01-01

    Solid or nodular enhancement is typical of soft tissue sarcomas although high grade soft tissue sarcomas and those with internal hemorrhage often appear heterogeneous with areas of nonenhancement and solid or nodular enhancement. These MRI findings often prompt an orthopedic oncology referral, a biopsy or surgery. However, not all masses with these imaging findings are malignant. We report the multimodality imaging findings of two surgically proven chronic expanding hematomas (CEH) with imaging features that mimicked sarcomas. A third case of nonenhancing CEH of the lower extremity is also presented as a comparison. It is important that in the correct clinical scenario with typical imaging findings, the differential diagnosis of a chronic expanding hematoma be included in the workup of these patients. An image-guided biopsy of nodular tissue within such masses that proves to be negative for malignancy should not necessarily be considered discordant. A correct diagnosis may prevent a morbid unnecessary surgery and may indicate the need for a conservative noninvasive follow-up with imaging.

  9. Detection of EWS/FLI-1 fusion in non-Ewing soft tissue tumors.

    Science.gov (United States)

    Trancău, I O; Huică, R; Surcel, M; Munteanu, A; Ursaciuc, C

    2015-01-01

    EWS/FLI-1 fusion mainly appears in Ewing's sarcoma or the primitive neuroectodermal tumors and represents a genomic marker for these tumors. However, it can appear with lower frequency in other soft tissue tumors. The paper investigates the presence of EWS/FLI-1 fusion in clinically diagnosed sarcoma belonging to different non-Ewing connective tissue tumors in order to search for a possible new biomarker valuable for investigators. 20 patients with soft tissue tumors, who underwent surgery, were tested. Intra-operative samples of normal and tumor tissue were collected for histopathological diagnosis and genetics determinations. The patients' RNA from tumor and normal peritumoral tissue was extracted and EWS/FLI-1 fusion screened by quantitative real-time PCR. The relative expression of the fusion in the tumor sample was compared to the similar expression in normal tissue. The amplification in the threshold zone was shown by 5 samples (25%): 2 clear cell sarcoma, 1 fibrosarcoma, 1 malignant tumor of nerve sheath, 1 metastatic adenocarcinoma. We differentiated between the unspecific amplification and concluded that these are weak positive results. Genomic investigation may establish the tumor malignancy and its possible affiliation earlier than histopathology. It can support the screening of EWS/FLI-1 fusion in a larger variety of clinically diagnosed soft tissue tumors.

  10. Ischiogluteal bursitis mimicking soft-tissue metastasis from a renal cell carcinoma

    International Nuclear Information System (INIS)

    Voelk, M.; Gmeinwieser, J.; Manke, C.; Strotzer, M.; Hanika, H.

    1998-01-01

    We report a case of ischiogluteal bursitis mimicking a soft-tissue metastasis from a renal cell carcinoma. A 66-year-old woman suffered from pain over the left buttock 6 months after she was operated on for renal cell carcinoma of the left kidney. CT of the abdomen and pelvis revealed a tumor-like lesion adjacent to the left os ischii, which was suspected to be a soft-tissue metastasis. Percutaneous biopsy revealed no evidence of malignancy, but the histopathological diagnosis of chronic bursitis. (orig.)

  11. The hands in metabolic skeletal diseases 1. A method of high-detailed contact radiography

    International Nuclear Information System (INIS)

    Shotemor, Sh.Sh.; Tret'yakov, A.E.

    1982-01-01

    A method of high-detailed contact radiography of the hands consists in the the screenless x-ray on the fine grained technical film employing microfocus with consecutive optical enlargement of the appearance. Various specimens of home-made tecinical film have been tried, the best results were obtained with the PT-5 film type (an opportunity of 7-fold optical magnification without interfering effect of the emulsion granularity). The method provides for a significant diagnostic advantage, affording to reveal minimal manifestations of subperiosteal, intracortical, and enosteal bone tissue resorption, as well as tiny calcinates in soft tissues. Pathological bone disorders were discovered in 63 out of 142 examined patients, suspected of metabolic diseases of the skeleton [ru

  12. Platelet-Rich Fibrin and Soft Tissue Wound Healing: A Systematic Review.

    Science.gov (United States)

    Miron, Richard J; Fujioka-Kobayashi, Masako; Bishara, Mark; Zhang, Yufeng; Hernandez, Maria; Choukroun, Joseph

    2017-02-01

    The growing multidisciplinary field of tissue engineering aims at predictably regenerating, enhancing, or replacing damaged or missing tissues for a variety of conditions caused by trauma, disease, and old age. One area of research that has gained tremendous awareness in recent years is that of platelet-rich fibrin (PRF), which has been utilized across a wide variety of medical fields for the regeneration of soft tissues. This systematic review gathered all the currently available in vitro, in vivo, and clinical literature utilizing PRF for soft tissue regeneration, augmentation, and/or wound healing. In total, 164 publications met the original search criteria, with a total of 48 publications meeting inclusion criteria (kappa score = 94%). These studies were divided into 7 in vitro, 11 in vivo, and 31 clinical studies. In summary, 6 out of 7 (85.7%) and 11 out of 11 (100%) of the in vitro and in vivo studies, respectively, demonstrated a statistically significant advantage for combining PRF to their regenerative therapies. Out of the remaining 31 clinical studies, a total of 8 reported the effects of PRF in a randomized clinical trial, with 5 additional studies (13 total) reporting appropriate controls. In those clinical studies, 9 out of the 13 studies (69.2%) demonstrated a statistically relevant positive outcome for the primary endpoints measured. In total, 18 studies (58% of clinical studies) reported positive wound-healing events associated with the use of PRF, despite using controls. Furthermore, 27 of the 31 clinical studies (87%) supported the use of PRF for soft tissue regeneration and wound healing for a variety of procedures in medicine and dentistry. In conclusion, the results from the present systematic review highlight the positive effects of PRF on wound healing after regenerative therapy for the management of various soft tissue defects found in medicine and dentistry.

  13. Angular photogrammetric analysis of the soft-tissue facial profile of Indian adults

    Directory of Open Access Journals (Sweden)

    K Saravana Pandian

    2018-01-01

    Full Text Available Introduction: Soft-tissue analysis has become an important component of orthodontic diagnosis and treatment planning. Photographic evaluation of an orthodontic patient is a very close representation of the appearance of the person. The previously established norms for soft-tissue analysis will vary for different ethnic groups. Thus, there is a need to develop soft-tissue facial profile norms pertaining to Indian ethnic groups. Aim and Objectives: The aim of this study is to establish the angular photogrammetric standards of soft-tissue facial profile for Indian males and females and also to compare sexual dimorphism present between them. Materials and Methods: The lateral profile photographs of 300 random participants (150 males and 150 females between ages 18 and 25 years were taken and analyzed using FACAD tracing software. Inclusion criteria were angles Class I molar occlusion with acceptable crowding and proclination, normal growth and development with well-aligned dental arches, and full complements of permanent teeth irrespective of third molar status. This study was conducted in Indian population, and samples were taken from various cities across India. Descriptive statistical analysis was carried out, and sexual dimorphism was evaluated by Student's t-test between males and females. Results: The results of the present study showed statistically significant (P < 0.05 gender difference in 5 parameters out of 12 parameters in Indian population. Conclusion: In the present study, soft-tissue facial measurements were established by means of photogrammetric analysis to facilitate orthodontists to carry out more quantitative evaluation and make disciplined decisions. The mean values obtained can be used for comparison with records of participants with the same characteristics by following this photogrammetric technique.

  14. Developing a multimodal biometric authentication system using soft computing methods.

    Science.gov (United States)

    Malcangi, Mario

    2015-01-01

    Robust personal authentication is becoming ever more important in computer-based applications. Among a variety of methods, biometric offers several advantages, mainly in embedded system applications. Hard and soft multi-biometric, combined with hard and soft computing methods, can be applied to improve the personal authentication process and to generalize the applicability. This chapter describes the embedded implementation of a multi-biometric (voiceprint and fingerprint) multimodal identification system based on hard computing methods (DSP) for feature extraction and matching, an artificial neural network (ANN) for soft feature pattern matching, and a fuzzy logic engine (FLE) for data fusion and decision.

  15. Real-time radiography, digital radiography, and computed tomography for nonintrusive waste drum characterization

    International Nuclear Information System (INIS)

    Martz, H.E.; Schneberk, D.J.; Roberson, G.P.

    1994-07-01

    We are investigating and developing the application of x-ray nondestructive evaluation (NDE) and gamma-ray nondestructive assay (NDA) methods to nonintrusively characterize 208-liter (55-gallon) mixed waste drums. Mixed wastes contain both hazardous and radioactive materials. We are investigating the use of x-ray NDE methods to verify the content of documented waste drums and determine if they can be used to identify hazardous and nonconforming materials. These NDE methods are also being used to help waste certification and hazardous waste management personnel at LLNL to verify/confirm and/or determine the contents of waste. The gamma-ray NDA method is used to identify the intrinsic radioactive source(s) and to accurately quantify its strength. The NDA method may also be able to identify some hazardous materials such as heavy metals. Also, we are exploring techniques to combine both NDE and NDA data sets to yield the maximum information from these nonintrusive, waste-drum characterization methods. In this paper, we report an our x-ray NDE R ampersand D activities, while our gamma-ray NDA activities are reported elsewhere in the proceedings. We have developed a data, acquisition scanner for x-ray NDE real-time radiography (RTR), as well as digital radiography transmission computed tomography (TCT) along with associated computational techniques for image reconstruction, analysis, and display. We are using this scanner and real-waste drums at Lawrence Livermore National Laboratory (LLNL). In this paper, we discuss some issues associated with x-ray imaging, describe the design construction of an inexpensive NDE drum scanner, provide representative DR and TCT results of both mock- and real-waste drums, and end with a summary of our efforts and future directions. The results of these scans reveal that RTR, DR, and CT imaging techniques can be used in concert to provide valuable information about the interior of low-level-, transuranic-, and mock-waste drums without

  16. Incidence of Staphylococcus aureus nasal colonization and soft tissue infection among high school football players.

    Science.gov (United States)

    Lear, Aaron; McCord, Gary; Peiffer, Jeffrey; Watkins, Richard R; Parikh, Arpan; Warrington, Steven

    2011-01-01

    Methicillin-resistant Staphylococcus aureus (MRSA) skin and soft tissue infections have been documented with increasing frequency in both team and individual sports in recent years. It also seems that the level of MRSA skin and soft tissue infections in the general population has increased. One hundred ninety athletes from 6 local high school football teams were recruited for this prospective observational study to document nasal colonization and the potential role this plays in skin and soft tissue infections in football players and, in particular, MRSA infections. Athletes had nasal swabs done before their season started, and they filled out questionnaires regarding potential risk factors for skin and soft tissue infections. Those enrolled in the study were then observed over the course of the season for skin and soft tissue infections. Those infected had data about their infections collected. One hundred ninety of 386 available student athletes enrolled in the study. Forty-four of the subjects had nasal colonization with methicillin-susceptible S. aureus, and none were colonized with MRSA. There were 10 skin and soft tissue infections (8 bacterial and 2 fungal) documented over the course of the season. All were treated as outpatients with oral or topical antibiotics, and none were considered serious. Survey data from the preseason questionnaire showed 21% with skin infection, 11% with methicillin-susceptible S. aureus, and none with MRSA infection during the past year. Three reported a remote history of MRSA infection. We documented an overall skin infection rate of 5.3% among high school football players over a single season. Our results suggest that skin and soft tissue infection may not be widespread among high school athletes in northeast Ohio.

  17. [Real-time PCR in rapid diagnosis of Aeromonas hydrophila necrotizing soft tissue infections].

    Science.gov (United States)

    Kohayagawa, Yoshitaka; Izumi, Yoko; Ushita, Misuzu; Niinou, Norio; Koshizaki, Masayuki; Yamamori, Yuji; Kaneko, Sakae; Fukushima, Hiroshi

    2009-11-01

    We report a case of rapidly progressive necrotizing soft tissue infection and sepsis followed by a patient's death. We suspected Vibrio vulnificus infection because the patient's underlying disease was cirrhosis and the course extremely rapid. No microbe had been detected at death. We extracted DNA from a blood culture bottle. SYBR green I real-time PCR was conducted but could not detect V. vulnificus vvh in the DNA sample. Aeromonas hydrophila was cultured and identified in blood and necrotized tissue samples. Real-time PCR was conducted to detect A. hydrophila ahh1, AHCYTOEN and aerA in the DNA sample extracted from the blood culture bottle and an isolated necrotized tissue strain, but only ahh1 was positive. High-mortality in necrotizing soft tissue infections makes it is crucial to quickly detect V. vulnificus and A. hydrophila. We found real-time PCR for vvh, ahh1, AHCYTOEN, and aerA useful in detecting V. vulnificus and A. hydrophila in necrotizing soft tissue infections.

  18. A Novel Nonlinear Parameter Estimation Method of Soft Tissues

    Directory of Open Access Journals (Sweden)

    Qianqian Tong

    2017-12-01

    Full Text Available The elastic parameters of soft tissues are important for medical diagnosis and virtual surgery simulation. In this study, we propose a novel nonlinear parameter estimation method for soft tissues. Firstly, an in-house data acquisition platform was used to obtain external forces and their corresponding deformation values. To provide highly precise data for estimating nonlinear parameters, the measured forces were corrected using the constructed weighted combination forecasting model based on a support vector machine (WCFM_SVM. Secondly, a tetrahedral finite element parameter estimation model was established to describe the physical characteristics of soft tissues, using the substitution parameters of Young’s modulus and Poisson’s ratio to avoid solving complicated nonlinear problems. To improve the robustness of our model and avoid poor local minima, the initial parameters solved by a linear finite element model were introduced into the parameter estimation model. Finally, a self-adapting Levenberg–Marquardt (LM algorithm was presented, which is capable of adaptively adjusting iterative parameters to solve the established parameter estimation model. The maximum absolute error of our WCFM_SVM model was less than 0.03 Newton, resulting in more accurate forces in comparison with other correction models tested. The maximum absolute error between the calculated and measured nodal displacements was less than 1.5 mm, demonstrating that our nonlinear parameters are precise.

  19. [Microbiological diagnosis of infections of the skin and soft tissues].

    Science.gov (United States)

    Burillo, Almudena; Moreno, Antonio; Salas, Carlos

    2007-11-01

    Skin and soft tissue infections are often seen in clinical practice, yet their microbiological diagnosis is among the most complex of laboratory tasks. The diagnosis of a skin and a soft tissue infection is generally based on clinical criteria and not microbiological results. A microbiological diagnosis is reserved for cases in which the etiology of infection is required, e.g., when the infection is particularly severe, when less common microorganisms are suspected as the causative agent (e.g. in immunocompromised patients), when response to antimicrobial treatment is poor, or when a longstanding wound does not heal within a reasonable period of time. We report the indications, sampling and processing techniques, and interpretation criteria for various culture types, including quantitative cultures from biopsy or tissue specimens and semiquantitative and qualitative cultures performed on all types of samples. For non-invasive samples taken from open wounds, application of the Q index to Gram stains is a cost-effective way to standardize sample quality assessment and interpretation of the pathogenic involvement of the different microorganisms isolated from cultures. All these issues are covered in the SEIMC microbiological procedure number 22: Diagnóstico microbiológico de las infecciones de piel y tejidos blandos (Microbiological diagnosis of infections of the skin and soft tissues) (2nd ed., 2006, www.seimc.org/protocolos/microbiologia).

  20. Diagnostic Imaging of the Lower Respiratory Tract in Neonatal Foals: Radiography and Computed Tomography.

    Science.gov (United States)

    Lascola, Kara M; Joslyn, Stephen

    2015-12-01

    Diagnostic imaging plays an essential role in the diagnosis and monitoring of lower respiratory disease in neonatal foals. Radiography is most widely available to equine practitioners and is the primary modality that has been used for the characterization of respiratory disease in foals. Computed tomography imaging, although still limited in availability to the general practitioner, offers advantages over radiography and has been used diagnostically in neonatal foals with respiratory disease. Recognition of appropriate imaging protocols and patient-associated artifacts is critical for accurate image interpretation regardless of the modality used. Copyright © 2015 Elsevier Inc. All rights reserved.

  1. Risk factors for pedicled flap necrosis in hand soft tissue reconstruction: a multivariate logistic regression analysis.

    Science.gov (United States)

    Gong, Xu; Cui, Jianli; Jiang, Ziping; Lu, Laijin; Li, Xiucun

    2018-03-01

    Few clinical retrospective studies have reported the risk factors of pedicled flap necrosis in hand soft tissue reconstruction. The aim of this study was to identify non-technical risk factors associated with pedicled flap perioperative necrosis in hand soft tissue reconstruction via a multivariate logistic regression analysis. For patients with hand soft tissue reconstruction, we carefully reviewed hospital records and identified 163 patients who met the inclusion criteria. The characteristics of these patients, flap transfer procedures and postoperative complications were recorded. Eleven predictors were identified. The correlations between pedicled flap necrosis and risk factors were analysed using a logistic regression model. Of 163 skin flaps, 125 flaps survived completely without any complications. The pedicled flap necrosis rate in hands was 11.04%, which included partial flap necrosis (7.36%) and total flap necrosis (3.68%). Soft tissue defects in fingers were noted in 68.10% of all cases. The logistic regression analysis indicated that the soft tissue defect site (P = 0.046, odds ratio (OR) = 0.079, confidence interval (CI) (0.006, 0.959)), flap size (P = 0.020, OR = 1.024, CI (1.004, 1.045)) and postoperative wound infection (P < 0.001, OR = 17.407, CI (3.821, 79.303)) were statistically significant risk factors for pedicled flap necrosis of the hand. Soft tissue defect site, flap size and postoperative wound infection were risk factors associated with pedicled flap necrosis in hand soft tissue defect reconstruction. © 2017 Royal Australasian College of Surgeons.

  2. Mechanical characterization of bioprinted in vitro soft tissue models

    International Nuclear Information System (INIS)

    Zhang, Ting; Ouyang, Liliang; Sun, Wei; Yan, Karen Chang

    2013-01-01

    Recent development in bioprinting technology enables the fabrication of complex, precisely controlled cell-encapsulated tissue constructs. Bioprinted tissue constructs have potential in both therapeutic applications and nontherapeutic applications such as drug discovery and screening, disease modelling and basic biological studies such as in vitro tissue modelling. The mechanical properties of bioprinted in vitro tissue models play an important role in mimicking in vivo the mechanochemical microenvironment. In this study, we have constructed three-dimensional in vitro soft tissue models with varying structure and porosity based on the 3D cell-assembly technique. Gelatin/alginate hybrid materials were used as the matrix material and cells were embedded. The mechanical properties of these models were assessed via compression tests at various culture times, and applicability of three material constitutive models was examined for fitting the experimental data. An assessment of cell bioactivity in these models was also carried out. The results show that the mechanical properties can be improved through structure design, and the compression modulus and strength decrease with respect to time during the first week of culture. In addition, the experimental data fit well with the Ogden model and experiential function. These results provide a foundation to further study the mechanical properties, structural and combined effects in the design and the fabrication of in vitro soft tissue models. (paper)

  3. Development of Soft Computing and Applications in Agricultural and Biological Engineering

    Science.gov (United States)

    Soft computing is a set of “inexact” computing techniques, which are able to model and analyze very complex problems. For these complex problems, more conventional methods have not been able to produce cost-effective, analytical, or complete solutions. Soft computing has been extensively studied and...

  4. Ischiogluteal bursitis mimicking soft-tissue metastasis from a renal cell carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Voelk, M.; Gmeinwieser, J.; Manke, C.; Strotzer, M. [Department of Radiology, University Hospital, Regensburg (Germany); Hanika, H. [Department of Urology, St. Josef Hospital, Regensburg (Germany)

    1998-09-01

    We report a case of ischiogluteal bursitis mimicking a soft-tissue metastasis from a renal cell carcinoma. A 66-year-old woman suffered from pain over the left buttock 6 months after she was operated on for renal cell carcinoma of the left kidney. CT of the abdomen and pelvis revealed a tumor-like lesion adjacent to the left os ischii, which was suspected to be a soft-tissue metastasis. Percutaneous biopsy revealed no evidence of malignancy, but the histopathological diagnosis of chronic bursitis. (orig.) With 2 figs., 8 refs.

  5. CMG2 Expression Is an Independent Prognostic Factor for Soft Tissue Sarcoma Patients

    Directory of Open Access Journals (Sweden)

    Thomas Greither

    2017-12-01

    Full Text Available The capillary morphogenesis gene 2 (CMG2, also known as the anthrax toxin receptor 2 (ANTXR2, is a transmembrane protein putatively involved in extracellular matrix (ECM adhesion and tissue remodeling. CMG2 promotes endothelial cell proliferation and exhibits angiogenic properties. Its downregulation is associated with a worsened survival of breast carcinoma patients. Aim of this study was to analyze the CMG2 mRNA and protein expression in soft tissue sarcoma and their association with patient outcome. CMG2 mRNA was measured in 121 tumor samples of soft tissue sarcoma patients using quantitative real-time PCR. CMG2 protein was evaluated in 52 tumor samples by ELISA. CMG2 mRNA was significantly correlated with the corresponding CMG2 protein expression (rs = 0.31; p = 0.027. CMG2 mRNA expression was associated with the mRNA expressions of several ECM and tissue remodeling enzymes, among them CD26 and components of the uPA system. Low CMG2 mRNA expression was correlated with a worsened patients’ disease-specific survival in Kaplan-Meier analyses (mean patient survival was 25 vs. 96 months; p = 0.013, especially in high-stage tumors. A decreased CMG2 expression is a negative prognostic factor for soft tissue sarcoma patients. CMG2 may be an interesting candidate gene for the further exploration of soft tissue sarcoma genesis and progression.

  6. CMG2 Expression Is an Independent Prognostic Factor for Soft Tissue Sarcoma Patients.

    Science.gov (United States)

    Greither, Thomas; Wedler, Alice; Rot, Swetlana; Keßler, Jacqueline; Kehlen, Astrid; Holzhausen, Hans-Jürgen; Bache, Matthias; Würl, Peter; Taubert, Helge; Kappler, Matthias

    2017-12-07

    The capillary morphogenesis gene 2 (CMG2), also known as the anthrax toxin receptor 2 (ANTXR2), is a transmembrane protein putatively involved in extracellular matrix (ECM) adhesion and tissue remodeling. CMG2 promotes endothelial cell proliferation and exhibits angiogenic properties. Its downregulation is associated with a worsened survival of breast carcinoma patients. Aim of this study was to analyze the CMG2 mRNA and protein expression in soft tissue sarcoma and their association with patient outcome. CMG2 mRNA was measured in 121 tumor samples of soft tissue sarcoma patients using quantitative real-time PCR. CMG2 protein was evaluated in 52 tumor samples by ELISA. CMG2 mRNA was significantly correlated with the corresponding CMG2 protein expression (r s = 0.31; p = 0.027). CMG2 mRNA expression was associated with the mRNA expressions of several ECM and tissue remodeling enzymes, among them CD26 and components of the uPA system. Low CMG2 mRNA expression was correlated with a worsened patients' disease-specific survival in Kaplan-Meier analyses (mean patient survival was 25 vs. 96 months; p = 0.013), especially in high-stage tumors. A decreased CMG2 expression is a negative prognostic factor for soft tissue sarcoma patients. CMG2 may be an interesting candidate gene for the further exploration of soft tissue sarcoma genesis and progression.

  7. Magnetic resonance imaging and computed radiography in Achilles tendon rupture

    International Nuclear Information System (INIS)

    Korenaga, Tateo; Hachiya, Junichi; Miyasaka, Yasuo

    1988-01-01

    Magnetic Resonance Imaging (MRI) and Computed Radiography (CR) were performed in 15 patients with complete Achilles tendon rupture who were treated conservatively without surgery. MRI was obtained using Toshiba MRT 50 A superconductive machine, operaing at 0.5 Tesla. CR was performed by CR-101, Fuji Medical System. In fresh cases, ruptured tendons showed intermediate signal intensity on T1-weighted images and high intensity on T2-weighted images. Thickening of the tendon was observed in all cases except in very acute stage. Configuration of thickend tendons tends to be dumbbell shape in subacute stage and fusiform in chronic stage of more than six months after the initial trauma. In cases which showed high signal intensity at the ruptured area both on T1 and T2 weighted images, migration of fat into the sapces between the ruptured tendons was considered to be the major source of increased signal intensity. Computed radiography showed thickening of the tendon, blurring of anterior margin of the tendon, and decreased translucency of pre-Achilles fat pad. However, MRI better demonstrated the details of ruptured tendons when compared to CR, and thought to be an usefull way of following up the healing process of the ruptured tendon to facilitate more reasonable judgement of the time of removing plaster casts and stating exercise. (author)

  8. A rate-jump method for characterization of soft tissues using nanoindentation techniques

    KAUST Repository

    Tang, Bin

    2012-01-01

    The biomechanical properties of soft tissues play an important role in their normal physiological and physical function, and may possibly relate to certain diseases. The advent of nanomechanical testing techniques, such as atomic force microscopy (AFM), nano-indentation and optical tweezers, enables the nano/micro-mechanical properties of soft tissues to be investigated, but in spite of the fact that biological tissues are highly viscoelastic, traditional elastic contact theory has been routinely used to analyze experimental data. In this article, a novel rate-jump protocol for treating viscoelasticity in nanomechanical data analysis is described. © 2012 The Royal Society of Chemistry.

  9. ultrasound reflecting the morphological properties in soft tissue

    DEFF Research Database (Denmark)

    Lorentzen, Torben; Larsen, Torben; Court-Payen, Michel

    2014-01-01

    Ultrasound (US) is an image modality providing the examiner with real-time images which reflect the morphological properties in soft tissue. Different types of transducers are used for different kind of exams. US is cheap, fast, and safe. US is widely used in abdominal imaging including obstetrics...

  10. Soft Tissue Sarcomas In Children And Adolescents

    International Nuclear Information System (INIS)

    Bajciova, V.

    2008-01-01

    Soft tissue sarcomas are rare tumors, they may occur at any age. It is heterogenous group of different histology types, different biology and different clinical behavior. Different treatment strategy is used for children and adults. Adolescents with sarcomas could be managed by both pediatric and medical oncologists. Decision regarding location of treatment should be based on the best patient interest. (author)

  11. Observer training for computer-aided detection of pulmonary nodules in chest radiography.

    Science.gov (United States)

    De Boo, Diederick W; van Hoorn, François; van Schuppen, Joost; Schijf, Laura; Scheerder, Maeke J; Freling, Nicole J; Mets, Onno; Weber, Michael; Schaefer-Prokop, Cornelia M

    2012-08-01

    To assess whether short-term feedback helps readers to increase their performance using computer-aided detection (CAD) for nodule detection in chest radiography. The 140 CXRs (56 with a solitary CT-proven nodules and 84 negative controls) were divided into four subsets of 35; each were read in a different order by six readers. Lesion presence, location and diagnostic confidence were scored without and with CAD (IQQA-Chest, EDDA Technology) as second reader. Readers received individual feedback after each subset. Sensitivity, specificity and area under the receiver-operating characteristics curve (AUC) were calculated for readings with and without CAD with respect to change over time and impact of CAD. CAD stand-alone sensitivity was 59 % with 1.9 false-positives per image. Mean AUC slightly increased over time with and without CAD (0.78 vs. 0.84 with and 0.76 vs. 0.82 without CAD) but differences did not reach significance. The sensitivity increased (65 % vs. 70 % and 66 % vs. 70 %) and specificity decreased over time (79 % vs. 74 % and 80 % vs. 77 %) but no significant impact of CAD was found. Short-term feedback does not increase the ability of readers to differentiate true- from false-positive candidate lesions and to use CAD more effectively. • Computer-aided detection (CAD) is increasingly used as an adjunct for many radiological techniques. • Short-term feedback does not improve reader performance with CAD in chest radiography. • Differentiation between true- and false-positive CAD for low conspicious possible lesions proves difficult. • CAD can potentially increase reader performance for nodule detection in chest radiography.

  12. Automatic measurement system for congenital hip dislocation using a computed radiography

    International Nuclear Information System (INIS)

    Komori, M.; Minato, K.; Hirakawa, A.; Kuwahara, M.

    1988-01-01

    Acetabular angle which is a diagnostic parameter of congenital hip dislocation has been measured manually in conventional X-ray film system. Using digital image directly provided from a computed radiography, an automatic measurement system was developed for this parameter. The process of the measurement was completed within a reasonable time, and accurate enough. The system was combined with an image database, so that it would be a measurement tool of PACS

  13. RADIOGRAPHY IN THE FIELD: ASSESSING A LIGHTWEIGHT, HANDHELD, BATTERY-POWERED DENTISTRY UNIT FOR FIELD DIAGNOSTIC APPLICATIONS.

    Science.gov (United States)

    Seilern-Moy, Katharina; Vielgrader, Hanna; Gerritsmann, Hanno; Walzer, Chris

    2017-03-01

    Radiography units are not used commonly in wildlife medicine field settings, primarily because of their weight and requirement for a power supply. In this study, a portable, battery-powered, and lightweight radiography unit, originally developed for dentistry, was assessed for its potential field applications. Radiographs of various animal species (ranging in weight from 14 g to 1,000 kg) were imaged using varying source image distance (SID) and exposure time. The quality of these images was evaluated for their resolution, image noise, and motion blur. When required, image resolutions were further enhanced using computed radiography postprocessing. Other parameters evaluated were the freehand use of the device, its battery durability, the maximum obtainable image size, and multiple use of a single computed radiography cassette. Using an SID of 60 cm, radiographs delivered adequate image quality. The quality, however, was found deteriorated in images of larger animals (>50 kg) or thicker tissues (>15 cm). The use of a tripod proved unnecessary in most cases, and its exclusion greatly facilitated equipment handling. Under field conditions, the battery was depleted after a total running time of 1.6 hr or 36 radiographs. The maximum size of a radiographic image reached a diameter of 40 cm, and radiation shielding allowed the multiple use of a single computed radiography cassette. Taken together, the radiography unit evaluated in this study presented a balanced compromise between portability and radiograph quality for field use. However, the unit image resolution cannot replace those of the fixed standard radiography units commonly used in veterinary medicine.

  14. Optical character recognition systems for different languages with soft computing

    CERN Document Server

    Chaudhuri, Arindam; Badelia, Pratixa; K Ghosh, Soumya

    2017-01-01

    The book offers a comprehensive survey of soft-computing models for optical character recognition systems. The various techniques, including fuzzy and rough sets, artificial neural networks and genetic algorithms, are tested using real texts written in different languages, such as English, French, German, Latin, Hindi and Gujrati, which have been extracted by publicly available datasets. The simulation studies, which are reported in details here, show that soft-computing based modeling of OCR systems performs consistently better than traditional models. Mainly intended as state-of-the-art survey for postgraduates and researchers in pattern recognition, optical character recognition and soft computing, this book will be useful for professionals in computer vision and image processing alike, dealing with different issues related to optical character recognition.

  15. Soft Tissue Closure of Grafted Extraction Sockets in the Anterior Maxilla: A Modified Palatal Pedicle Connective Tissue Flap Technique.

    Science.gov (United States)

    El Chaar, Edgard; Oshman, Sarah; Cicero, Giuseppe; Castano, Alejandro; Dinoi, Cinzia; Soltani, Leila; Lee, Yoonjung Nicole

    Localized ridge resorption, the consequence of socket collapse, following tooth extraction in the anterior maxilla can adversely affect esthetics, function, and future implant placement. Immediate grafting of extraction sockets may help preserve natural ridge contours, but a lack of available soft tissue can compromise the final esthetic outcome. The presented modified rotated palatal pedicle connective tissue flap is a useful technique for simultaneous soft tissue coverage and augmentation of grafted sockets to improve esthetic outcome. This article delineates its advantages through the presentation of a four-case series using this new technique.

  16. Mammary-type myofibroblastoma of soft tissue

    Directory of Open Access Journals (Sweden)

    Nebojsa Arsenovic

    2011-01-01

    Full Text Available A 40-year-old woman presented with a 1 year history of a painless, subcutaneous lump on the right buttock. Clinical examination showed an approximately 6 cm large subcutaneous mass covered by apparently normal-looking skin. No inguinal lymphadenopathy was found. The mass was excised with the clinical diagnosis of fibroma. Histologically, the lesion was consistent with mammary-type myofibroblastoma of soft tissue, a very rare, benign mesenchymal neoplasm with myofibroblastic differentiation. After surgical excision she was free of recurrence over a period of 8 months. This article also challenges the theory that suggests the origin of this tumor to be from the embryonic mammary tissue, adding another case of a site other than the milk lines.

  17. Performance evaluation of a computed radiography system

    Energy Technology Data Exchange (ETDEWEB)

    Roussilhe, J.; Fallet, E. [Carestream Health France, 71 - Chalon/Saone (France); Mango, St.A. [Carestream Health, Inc. Rochester, New York (United States)

    2007-07-01

    Computed radiography (CR) standards have been formalized and published in Europe and in the US. The CR system classification is defined in those standards by - minimum normalized signal-to-noise ratio (SNRN), and - maximum basic spatial resolution (SRb). Both the signal-to-noise ratio (SNR) and the contrast sensitivity of a CR system depend on the dose (exposure time and conditions) at the detector. Because of their wide dynamic range, the same storage phosphor imaging plate can qualify for all six CR system classes. The exposure characteristics from 30 to 450 kV, the contrast sensitivity, and the spatial resolution of the KODAK INDUSTREX CR Digital System have been thoroughly evaluated. This paper will present some of the factors that determine the system's spatial resolution performance. (authors)

  18. Radiogenic cancer induction associated with spinal radiography: a quantitative analysis

    International Nuclear Information System (INIS)

    Fickel, T.E.

    1988-01-01

    Computations of organ-specific radiation absorption by lung, breast, thyroid, active bone marrow and uterine tissues are used to rank sectional and full spine radiographic procedures according to their potentials for cancer induction. Assuming that the dose-effect relationship of radiation damage is linear and lacks a threshold effect, the prospective and retrospective carcinogenicities of commonly ordered spinal series are estimated. Cervical radiography is demonstrated to pose the least hazard to the patient, while full spine and lumbar (five views) procedures have the greatest. Organs most at risk as a result of spinal radiography are lung (thoracic and full spine), colon (lumbar and full spine), breast (thoracic and full spine), and prostate (full spine and lumbar)

  19. Phase II Study of Neoadjuvant Bevacizumab and Radiotherapy for Resectable Soft Tissue Sarcomas

    International Nuclear Information System (INIS)

    Yoon, Sam S.; Duda, Dan G.; Karl, Daniel L.; Kim, Tae-Min; Kambadakone, Avinash R.; Chen, Yen-Lin; Rothrock, Courtney; Rosenberg, Andrew E.; Nielsen, G. Petur; Kirsch, David G.; Choy, Edwin; Harmon, David C.; Hornicek, Francis J.; Dreyfuss, Jonathan; Ancukiewicz, Marek

    2011-01-01

    Purpose: Numerous preclinical studies have demonstrated that angiogenesis inhibitors can increase the efficacy of radiotherapy (RT). We sought to examine the safety and efficacy of bevacizumab (BV) and RT in soft tissue sarcomas and explore biomarkers to help determine the treatment response. Methods and Materials: Patients with ≥5 cm, intermediate- or high-grade soft tissue sarcomas at significant risk of local recurrence received neoadjuvant BV alone followed by BV plus RT before surgical resection. Correlative science studies included analysis of the serial blood and tumor samples and serial perfusion computed tomography scans. Results: The 20 patients had a median tumor size of 8.25 cm, with 13 extremity, 1 trunk, and 6 retroperitoneal/pelvis tumors. The neoadjuvant treatment was well tolerated, with only 4 patients having Grade 3 toxicities (hypertension, liver function test elevation). BV plus RT resulted in ≥80% pathologic necrosis in 9 (45%) of 20 tumors, more than double the historical rate seen with RT alone. Three patients had a complete pathologic response. The median microvessel density decreased 53% after BV alone (p <.05). After combination therapy, the median tumor cell proliferation decreased by 73%, apoptosis increased 10.4-fold, and the blood flow, blood volume, and permeability surface area decreased by 62–72% (p <.05). Analysis of gene expression microarrays of untreated tumors identified a 24-gene signature for treatment response. The microvessel density and circulating progenitor cells at baseline and the reduction in microvessel density and plasma soluble c-KIT with BV therapy also correlated with a good pathologic response (p <.05). After a median follow-up of 20 months, only 1 patient had developed local recurrence. Conclusions: The results from the present exploratory study indicated that BV increases the efficacy of RT against soft tissue sarcomas and might reduce the incidence of local recurrence. Thus, this regimen warrants

  20. Age-related changes in dynamic compressive properties of trochanteric soft tissues over the hip.

    Science.gov (United States)

    Choi, W J; Russell, C M; Tsai, C M; Arzanpour, S; Robinovitch, S N

    2015-02-26

    Hip fracture risk increases dramatically with age, and 90% of fractures are due to falls. During a fall on the hip, the soft tissues overlying the hip region (skin, fat, and muscle) act as shock absorbers to absorb energy and reduce the peak force applied to the underlying bone. We conducted dynamic indentation experiments with young women (aged 19-30; n=17) and older women (aged 65-81; n=17) to test the hypothesis that changes occur with age in the stiffness and damping properties of these tissues. Tissue stiffness and damping were derived from experiments where subjects lay sideways on a bed with the greater trochanter contacting a 3.8cm diameter indenter, which applied sinusoidal compression between 5 to 30Hz with a peak-to-peak amplitude of 1mm. Soft tissue thickness was measured using ultrasound. On average, stiffness was 2.9-fold smaller in older than young women (5.7 versus 16.8kN/m, p=0.0005) and damping was 3.5-fold smaller in older than young women (81 versus 282Ns/m, p=0.001). Neither parameter associated with soft tissue thickness. Our results indicate substantial age-related reductions in the stiffness and damping of soft tissues over the hip region, which likely reduce their capacity to absorb and dissipate energy (before "bottoming out") during a fall. Strategies such as wearable hip protectors or compliant flooringmay compensate for age-related reductions in the shock-absorbing properties of soft tissues and decrease the injury potential of falls. Copyright © 2014 Elsevier Ltd. All rights reserved.