WorldWideScience

Sample records for sodium per-carbonate injection

  1. Sodium Ferric Gluconate Injection

    Science.gov (United States)

    Sodium ferric gluconate injection is used to treat iron-deficiency anemia (a lower than normal number of ... are also receiving the medication epoetin (Epogen, Procrit). Sodium ferric gluconate injection is in a class of ...

  2. 77 FR 71006 - Sodium Nitrite Injection and Sodium Thiosulfate Injection Drug Products Labeled for the Treatment...

    Science.gov (United States)

    2012-11-28

    ... poisoning and unapproved injectable drug products containing sodium thiosulfate labeled for the treatment of... for the treatment of cyanide poisoning are new drugs that require approved new drug applications (NDAs... Injection and Sodium Thiosulfate Injection drug product, labeled for treatment of acute cyanide poisoning...

  3. Penicillin G (Potassium, Sodium) Injection

    Science.gov (United States)

    Penicillin G injection is used to treat and prevent certain infections caused by bacteria. Penicillin G injection is in a class of medications called penicillins. It works by killing bacteria that cause infections. ...

  4. Sodium Nitrite and Sodium Thiosulfate Are Effective Against Acute Cyanide Poisoning When Administered by Intramuscular Injection.

    Science.gov (United States)

    Bebarta, Vikhyat S; Brittain, Matthew; Chan, Adriano; Garrett, Norma; Yoon, David; Burney, Tanya; Mukai, David; Babin, Michael; Pilz, Renate B; Mahon, Sari B; Brenner, Matthew; Boss, Gerry R

    2017-06-01

    The 2 antidotes for acute cyanide poisoning in the United States must be administered by intravenous injection. In the out-of-hospital setting, intravenous injection is not practical, particularly for mass casualties, and intramuscular injection would be preferred. The purpose of this study is to determine whether sodium nitrite and sodium thiosulfate are effective cyanide antidotes when administered by intramuscular injection. We used a randomized, nonblinded, parallel-group study design in 3 mammalian models: cyanide gas inhalation in mice, with treatment postexposure; intravenous sodium cyanide infusion in rabbits, with severe hypotension as the trigger for treatment; and intravenous potassium cyanide infusion in pigs, with apnea as the trigger for treatment. The drugs were administered by intramuscular injection, and all 3 models were lethal in the absence of therapy. We found that sodium nitrite and sodium thiosulfate individually rescued 100% of the mice, and that the combination of the 2 drugs rescued 73% of the rabbits and 80% of the pigs. In all 3 species, survival in treated animals was significantly better than in control animals (log rank test, Pcyanide poisoning in 3 clinically relevant animal models of out-of-hospital emergency care. Copyright © 2016 American College of Emergency Physicians. Published by Elsevier Inc. All rights reserved.

  5. Sodium bicarbonate in-duct injection with sodium sulfate recovery for SO2/NOx control

    International Nuclear Information System (INIS)

    Bennett, R.; Darmstaedter, E.

    1991-01-01

    Dry sodium injection with sodium bicarbonate has been used commercially at industrial sites since the mid 1980's. In the past three years, five full scale commercial demonstrations have been completed on electric utility coal fired units. Up to 75% SO 2 removal with 0-40% NO x removal has been achieved on units equipped with ESPs. Recent slip stream studies have proven up to 90% SO 2 removal and 25% NO x removal when injection is ahead of a baghouse. If dry sodium bicarbonate sorbent injection technology is used prior to a retrofitted baghouse, but after an existing ESP the sodium sulfate by-product/flyash mixture in the baghouse is over 90% Na 2 SO 4 . Simple filtration and crystallization will yield a high value 99% + pure Na 2 SO 4 for sale. In this application, no liquid discharge occurs and potentially no solids discharge, since flyash recovered from the filter is either recycled to the boiler with the coal stream or reinjected into the boiler. EPA IAPCS model Version 4 is modified to project costs for this SO 2 /NO x removal technology when couples with Na 2 SO 4 recovery. In this paper an example is used to show hardware requirements, consumables accountability, by-product recovery rates, capital costs and levelized costs

  6. Suicide Attempts with Sodium Hipochlorid Injection: Case Report

    Directory of Open Access Journals (Sweden)

    Cemil Kavalci

    2013-08-01

    Full Text Available A suicide attempt is a health problem affecting all age groups. Suicides are usually by medicine overdose, gun-shot injury and hanging. 35 year old male patient was brought to our emergency department by 112 EMS due to suicidal attempt. Approximately two hours before the story of both arms, by iv injection of sodium hipochlorid was learned that he wants to commit suicide. On physical examination, his right arm 3,5 cm in diameter and his left arm 3 cm diameter red color ecchymosis and edema was present. There was no evidence of sistemical pathological finding. The patient was discharged after 24 hours of observation.

  7. Stability study of methotrexate in 0.9% sodium chloride injection and 5% dextrose injection with limit tests for impurities

    DEFF Research Database (Denmark)

    Nissen, Klaus; Bogedal Jorgensen, Lene; Lindegaard Berg, Dorthe

    2017-01-01

    Purpose. Results of an evaluation of the stability of methotrexate in 0.9% sodium chloride injection and 5% dextrose injection are presented. Methods. Methotrexate concentrated solution (100 mg/mL) was diluted to nominal concentrations of 0.2 and 20 mg/mL in infusion bags containing 0.9% sodium...... chloride injection or 5% dextrose injection. The filled bags were stored for 28 days at 25 °C and 60% relative humidity and protected from light. Samples were withdrawn for analysis on the day of preparation and after 3, 7, 14, 21, and 28 days. The test program included visual inspections, measurements...... in amounts of known and unknown degradation products were detected. In 5% dextrose injection, methotrexate at the higher concentration was stable for 28 days, with minor formation of degradation products; in the 0.2-mg/mL solution, however, methotrexate was stable for only 3 days. At later time points...

  8. The effect on serum enzymes of intramuscular injections of digoxin, bumetanide, pentazocine and isotonic sodium chloride

    DEFF Research Database (Denmark)

    Andersen, Klaus Ejner; Damsgaard, T

    1976-01-01

    Intramuscular injections of digoxin, bumetanide, pentazocine or isotonic sodium chloride have been given to 39 patients. We followed the serum concentrations of creatine kinase (CK), aspartate aminotransferase (ASAT), lactate dehydrogenase (LDH) and LDH isoenzymes for 4 days. Ten patients receiving...

  9. 21 CFR 522.468 - Colistimethate sodium powder for injection.

    Science.gov (United States)

    2010-04-01

    ... SERVICES (CONTINUED) ANIMAL DRUGS, FEEDS, AND RELATED PRODUCTS IMPLANTATION OR INJECTABLE DOSAGE FORM NEW... injection in the neck of 1- to 3-day-old chickens. Not for use in laying hens producing eggs for human...

  10. Stability of penicillin G sodium diluted with 0.9% sodium chloride injection or 5% dextrose injection and stored in polyvinyl chloride bag containers and elastomeric pump containers.

    Science.gov (United States)

    Hossain, Mirza Akram; Friciu, Mihaela; Aubin, Sebastien; Leclair, Grégoire

    2014-04-15

    The stability of penicillin G sodium solutions stored in polyvinyl chloride (PVC) bags or elastomeric pump containers was studied. Test samples were prepared by diluting powdered penicillin G sodium (10 million units/10-mL vial) to solutions of 2,500 or 50,000 units/mL with 0.9% sodium chloride injection or 5% dextrose injection. The preparations were transferred to 250-mL PVC bags and elastomeric pump containers. All samples were prepared in triplicate and stored at 5°C. Chemical stability was measured by a stability-indicating high-performance liquid chromatographic (HPLC) assay and by pH evaluation. Particulate matter was evaluated according to compendial standards using a light-obscuration particle count test. Preparations were visually examined throughout the study. After 21 days of storage, all test samples remained chemically stable, with an HPLC assay recovery value of more than 90% of the initial value. After 28 days, all samples prepared with either diluent and stored in PVC bags, as well as the samples diluted to 2,500 units/mL with sodium chloride injection and stored in elastomeric pump containers, did not meet the recovery acceptance limit. For all test samples, the mean pH consistently decreased during storage, from about 6.4 to about 5.5. Particle counts remained acceptable throughout the study, and no change in appearance was observed. Penicillin G for injection (2,500 and 50,000 units/mL) diluted in 0.9% sodium chloride injection or 5% dextrose injection and stored at 5°C in PVC containers or elastomeric pump containers was physically and chemically stable for a period of at least 21 days.

  11. The hemostatic effect of endoscopic sodium hyaluronate injection in peptic ulcer bleeding.

    Science.gov (United States)

    Cho, Yong Kyun; Kim, Chang Seop; Kim, Si Young; Park, Jung Ho; Kim, Hong Joo; Park, Dong Il; Sohn, Chong H; Jeon, Woo Kyu; Kim, Byung Ik; Shin, Jun Ho; Son, Byung Ho

    2007-06-01

    Endoscopic injection therapy is a well-established method of controlling peptic ulcer bleeding but it is not clear which agent would be the best choice for injection material. In this study, we evaluated the effect of Sodium Hyaluronate for control of ulcer bleeding. The subjects consisted of 26 patients with major peptic ulcer hemorrhage from June 2000 to August 2001. There were 17 gastric ulcers, 7 duodenal ulcers and 2 ulcers at anastomosis site. According to modified Forrest classifications, there were 7 active bleeding (spurting, 3; oozing, 4) and 19 stigmata of recent hemorrhage (visible vessel, 14; fresh blood clots, 5). Sodium Hyaluronate-saline solution was injected to control the bleeding. The initial and permanent hemostatic rate, rebleeding rate, and other complications were retrospectively evaluated. The initial hemostatic rate was 25/26 (96.2%) and re-bleeding rate 3/26 (11.5%). The success rate of the second trial of Sodium Hyaluronate injection was 3/3 (100%). Overall, the permanent hemostatic rate was 25/26 (96.2%) and there were no complications related to Sodium Hyaluronate injection. Sodium Hyaluronate is an excellent candidate agent for endoscopic injection therapy because of its convenience and safety. Further prospective randomized trials with other hemostatic methods are needed.

  12. Pilot scale-SO{sub 2} control by dry sodium bicarbonate injection and an electrostatic precipitator

    Energy Technology Data Exchange (ETDEWEB)

    Pliat, M.J.; Wilder, J.M. [University of Washington, Seattle, WA (United States). Dept. of Civil & Environmental Engineering

    2007-10-15

    A 500 actual cubic feet gas per minute (acfm) pilot-scale SO{sub 2} control study was undertaken to investigate flue gas desulfurization (FGD) by dry sodium sorbents in 400{sup o}F (204.5{sup o}C) flue gases emitted from a coal fired boiler with flue gas concentrations between 350 and 2500 ppm SO{sub 2}. Powdered sodium alkaline reagents were injected into the hot flue gas downstream of the air preheater and the spent reagents were collected using an electrostatic precipitator. Three different sorbents were used: processed sodium bicarbonate of two particle sizes; solution mined sodium bicarbonate, and processed sodium sesquicarbonate. SO{sub 2} concentrations were measured upstream of the reagent injection, 25-ft (7.62 m) downstream of the injection point, and downstream of the electrostatic precipitator. SO{sub 2} collection efficiencies ranged from 40 to 80% using sodium bicarbonate stoichiometric ratios from 0.5 to 3.0. Much of the in-duct SO{sub 2} removal occurred during the first second of reagent reaction time, indicating that the sulfur dioxide-sodium reaction rates may be faster than have been measured for fixed bed measurements reported in the literature.

  13. Compatibility and Stability of VARUBI (Rolapitant) Injectable Emulsion Admixed with Intravenous Palonosetron Hydrochloride Injection and Dexamethasone Sodium Phosphate Injection.

    Science.gov (United States)

    Wu, George; Powers, Dan; Yeung, Stanley; Chen, Frank

    2018-01-01

    Prophylaxis or therapy with a combination of a neurokinin 1 (NK-1) receptor antagonist (RA), a 5-hydroxytryptamine-3 (5-HT3) RA, and dexamethasone is recommended by international antiemesis guidelines for the prevention of chemotherapy-induced nausea and vomiting for patients receiving highly emetogenic chemotherapy and for selected patients receiving moderately emetogenic chemotherapy. VARUBI (rolapitant) is a substance P/NK-1 RA that was recently approved by the U.S. Food and Drug Administration as an injectable emulsion in combination with other antiemetic agents in adults for the prevention of delayed nausea and vomiting associated with initial and repeat courses of emetogenic cancer chemotherapy, including, but not limited to, highly emetogenic chemotherapy. Palonosetron is one of the 5-HT3 RAs indicated for the prevention of nausea and/or vomiting associated with initial and repeat courses of emetogenic cancer therapy, including high-dose cisplatin. Herein, we describe the physical and chemical compatibility and stability of VARUBI injectable emulsion (166.5 mg/92.5 mL [1.8 mg/mL, free base], equivalent to 185 mg of rolapitant hydrochloride) admixed with palonosetron injection 0.25 mg free base in 5 mL (equivalent to 0.28 mg hydrochloride salt) and with either 5 mL (20 mg) or 2.5 mL (10 mg) of dexamethasone sodium phosphate. Admixtures were prepared and stored in VARUBI injectable emulsion ready-to-use glass vials as supplied by the rolapitant manufacturer and in four types of commonly used intravenous administration (tubing) sets. Assessment of the physical and chemical compatibility and stability of the admixtures in the VARUBI ready-to-use vials stored at room temperature (20°C to 25°C) under fluorescent light and under refrigeration (2°C to 8°C protected from light) was conducted at 0, 1, 6, 24, and 48 hours, and that of the admixtures in the intravenous tubing sets was evaluated at 0, 2, and 6 hours of storage at 20°C to 25°C. Physical stability

  14. 21 CFR 522.2404 - Thialbarbitone sodium for injection.

    Science.gov (United States)

    2010-04-01

    ... Section 522.2404 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES.... (1) The drug is administered as a general anesthetic in surgical procedures on dogs, cats, swine... surgery. (2) It is administered intravenously. The drug is injected slowly to dogs, cats, cattle, sheep...

  15. 21 CFR 522.1884 - Prednisolone sodium succinate injection.

    Science.gov (United States)

    2010-04-01

    ... other stress conditions at intervals of 12, 24, or 48 hours, depending upon the size of the animal, the... (CONTINUED) ANIMAL DRUGS, FEEDS, AND RELATED PRODUCTS IMPLANTATION OR INJECTABLE DOSAGE FORM NEW ANIMAL DRUGS... maintenance doses at 1, 3, 6, or 10 hour intervals, as determined by the condition of the animal, for...

  16. Management of Tennis Elbow with sodium hyaluronate periarticular injections

    Directory of Open Access Journals (Sweden)

    Petrella Robert J

    2010-02-01

    Full Text Available Abstract Objectives To determine the efficacy and safety of peri-articular hyaluronic acid injections in chronic lateral epicondylosis (tennis elbow. Design Prospective randomized clinical trial in primary care sport medicine. Patients Three hundred and thirty one consecutive competitive racquette sport athletes with chronic (>3 months lateral epicondylosis were administered 2 injections (first injection at baseline into the subcutaneous tissue and muscle 1 cm. from the lateral epicondyle toward the primary point of pain using a two-dimensional fanning technique. A second injection was administered 1 week later. Outcomes measures Assessments were done at baseline, days 7, 14, 30, 90 and 356. Efficacy measures included patient's visual analogue scale (VAS of pain at rest (0-100 mm and following assessment of grip strength (0-100 mm. Grip strength was determined using a jamar hydraulic hand dynamometer. Other assessments included patients' global assessment of elbow injury (5 point categorical scale; 1 = no disability, 5 = maximal disability, patients' assessment of normal function/activity (5 point categorical scale, patients/physician satisfaction assessment (10 point categorical scale, time to return to pain-free and disability-free sport and adverse events as per WHO definition. Differences between groups were determined using an intent-to-treat ANOVA. Results Average age of the study population was 49 years (± 12 years. One hundred and sixty-five patients were randomized to the HA and 166 were randomized to the control groups. The change in VAS pain was -6.7 (± 2.0 for HA vs -1.3 (± 1.5 for control (p Conclusion Peri-articular HA treatment for tennis elbow was significantly better than control in improving pain at rest and after maximal grip testing. Further, HA treatment was highly satisfactory by patients and physicians and resulted in better return to pain free sport compared to control.

  17. [Accidental injection of sodium hypochlorite in inferior alveolar nerve block anesthesia].

    Science.gov (United States)

    Hongyan, Li; Jian, Xu; Baorong, Zhang; Yue, Jia; Minhua, Liu; Yilang, Luo; Jing, Zhao

    2016-12-01

    Sodium hypochlorite (NaClO) has been widely used in clinical practice as one of the most efficient root canal irrigants. Its properties include broad-spectrum antimicrobial activity and ability to dissolve necrotic tissues. However, when used improperly, NaClO can cause a series of adverse reactions, such as mucosal inflammation, irritation, or injury. This paper presents a case of accidental injection of NaClO in inferior alveolar nerve block anesthesia.

  18. Acute selenium toxicity in lambs following intramuscular injection of sodium selenite

    Energy Technology Data Exchange (ETDEWEB)

    Caravaggi, C; Clark, F L; Jackson, A R.B.

    1970-01-01

    The LD50 in lambs from a farm where selenium deficiency has not been recorded was found to be 45..mu..g. of Se/kg. body weight when sodium selenite was administered as a single intramuscular injection. Marked pulmonary congestion and oedema were constantly present with degenerative changes in liver and kidney. A similarity was noted between the autopsy findings of acute selenosis and those described for enterotoxaemia. 13 references, 4 figures.

  19. The effect of sodium salicylate injection on spatial learning and memory of rat

    Directory of Open Access Journals (Sweden)

    Leila Azimi

    2011-11-01

    Full Text Available Background: Cyclooxygenase (COX enzyme known as a regulatory factor in synaptic plasticity. It has been reported that synaptic plasticity is one of the mechanisms involved in learning and memory processes. In the current study peripheral injection's effects of sodium salicylate (as a non selective COX inhibitor on spatial learning and memory have been investigated.Methods: Four groups of male rats received different doses of sodium salicylate (0, 200, 300, 400 mg/kg; i.p.. Studies were performed using Morris Water Maze (MWM. Spatial learning and memory parameters were subjected to the one- and two-way analyses of variance (ANOVAs followed by Tukey’s post hoc test.Results: Data showed that intraperitoneal injection of sodium salicylate had not significant effect on spatial learning parameters (including escape latency and traveled distance to hidden platform in training days; but administration of high dose of the drug (400 mg/kg significantly increased the percentage of time that animals spent in the target quadrant in probe trial testing. Conclusion: Peripheral injection of the COX inhibitor has no significant effect on spatial learning; but potentiates spatial memory consolidation using MWM.

  20. Sodium bicarbonate injection: a small-plant SO sub 2 /NO sub x option

    Energy Technology Data Exchange (ETDEWEB)

    Darmstaedter, E. (NaTec Resources Inc. (USA). Environmental Systems Division)

    1990-12-01

    The sodium bicarbonate injection process provides a cost effective alternative to flue gas desulfurization for smaller power plants. EPRI and NaTec Resources have been conducting demonstrations on coal-fired utility boilers. 90% SO{sub 2} reduction was achieved in EPRI's High-Sulfur Test Centre 4 MW pilot HYPAS installation near Barker, NY. During 1990 Public Service Company of Colorado and NaTec completed a two-phase commercial demonstration for continuous SO{sub 2}/NO{sub x} control on Cherokee Unit 1 to determine levels of urea and injection locations for urea and sodium bicarbonate to minimise NO{sub 2} and NH{sub 3} emissions while maintaining a high level of SO{sub 2} reduction. Methods for sodium sulphate by-product recovery/sale are described - these are higher value than those from the limestone process. Costs for the whole process, driven by sorbent costs, work out typically for a dry sorbent injection/HYPAS system at $610/ton SO{sub 2} removed. 11 refs., 5 figs., 1 tab.

  1. Optimization of sodium bicarbonate injection for acid scrubbing in hospital waste incineration plant

    International Nuclear Information System (INIS)

    Rozainee, M.; Salleh, M.; Mutahharah, M.M.; Anwar Johari

    2010-01-01

    Optimization of sodium bicarbonate (NaHCO 3 ) injection for acid hydrochloric (HCl) scrubbing was conducted on a hospital waste incineration plant. The plant employs a rotary kiln system having burning capacity of 350 kg/h hospital waste (average calorific value of 17.4 MJ/kg) and is operated on a 24 hr/ day basis. Currently, NaHCO 3 injection rate is 25 kg/h as recommended by manufacturer to meet the Department of Environment (DOE) standard emission limit of 200 mg/Nm 3 HCl. Testing of HCl emission at various injection rates of 25, 20, 15 and 10 kg/ h results in HCl final concentration in the range of 0.58-7.13, 5.63-7.74, 0.07-2.99 and 3-28 mg/Nm 3 respectively. The results showed that NaHCO 3 injection rate as low as 10 kg/ h could still meet the HCl stipulated emission limit. Economic comparison between 25 and 10 kg/ h injection rates showed that total saving on NaHCO 3 and disposal of fly ash was RM 22,000 per month (equivalent to saving RM 260,000 per year) when using 10 kg/ h injection rate. It was concluded from the study that optimum injection rate would not only save cost and reduce wastage but also reduce bag house loading rate and prolong the life span of filter bags. (author)

  2. Dextrose and morrhuate sodium injections (prolotherapy) for knee osteoarthritis: a prospective open-label trial.

    Science.gov (United States)

    Rabago, David; Patterson, Jeffrey J; Mundt, Marlon; Zgierska, Aleksandra; Fortney, Luke; Grettie, Jessica; Kijowski, Richard

    2014-05-01

    This study determined whether injection with hypertonic dextrose and morrhuate sodium (prolotherapy) using a pragmatic, clinically determined injection schedule for knee osteoarthritis (KOA) results in improved knee pain, function, and stiffness compared to baseline status. This was a prospective three-arm uncontrolled study with 1-year follow-up. The setting was outpatient. The participants were 38 adults who had at least 3 months of symptomatic KOA and who were in the control groups of a prior prolotherapy randomized controlled trial (RCT) (Prior-Control), were ineligible for the RCT (Prior-Ineligible), or were eligible but declined the RCT (Prior-Declined). The injection sessions at occurred at 1, 5, and 9 weeks with as-needed treatment at weeks 13 and 17. Extra-articular injections of 15% dextrose and 5% morrhuate sodium were done at peri-articular tendon and ligament insertions. A single intra-articular injection of 6 mL 25% dextrose was performed through an inferomedial approach. The primary outcome measure was the validated Western Ontario McMaster University Osteoarthritis Index (WOMAC). The secondary outcome measure was the Knee Pain Scale and postprocedure opioid medication use and participant satisfaction. The Prior-Declined group reported the most severe baseline WOMAC score (p=0.02). Compared to baseline status, participants in the Prior-Control group reported a score change of 12.4±3.5 points (19.5%, p=0.002). Prior-Decline and Prior-Ineligible groups improved by 19.4±7.0 (42.9%, p=0.05) and 17.8±3.9 (28.4%, p=0.008) points, respectively; 55.6% of Prior-Control, 75% of Prior-Decline, and 50% of Prior-Ineligible participants reported score improvement in excess of the 12-point minimal clinical important difference on the WOMAC measure. Postprocedure opioid medication resulted in rapid diminution of prolotherapy injection pain. Satisfaction was high and there were no adverse events. Prolotherapy using dextrose and morrhuate sodium injections for

  3. Efficacy Of A Single-Injection Sodium Hyaluronate Treatment In Lateral Epicondylitis.

    Science.gov (United States)

    Khan, Inam Ullah; Awan, Abdus Saboor; Khan, Aimal Sattar; Marwat, Imran; Meraj, Muhammad

    2018-01-01

    Lateral epicondylitis or tennis elbow is a disease of tendons arising from common extensor origin at the lateral epicondyle of elbow and is commonly characterized by pain on supination of forearms as well as extension of fingers and wrists. This descriptive case series aims to determine the efficacy of a single-injection sodium hyaluronate treatment for lateral epicondylitis. The study was conducted at the Department of Orthopaedics. Ayub Teaching Hospital Abbottabad. From February 1 to August 31, 2014. Patients diagnosed with lateral epicondylitis were administered 1 cc of 1% Sodium hyaluronate 1 cm from the lateral epicondyle into the soft tissue. Hyaluronic acid is more effective in patients with moderate pain of lateral epicondylitis (VAS score ≤7 than in patients with severe pain (VAS score >7). Paired sample t-test was used to compared the means of the pre- and post-procedure VAS score and the difference was found to be statistically very significant (p=0.00) with a mean±SD change in VAS of 2.31±1.35 at 4 weeks. A single injection of sodium hyaluronate is effective in management of moderate, but not severe pain of lateral epicondylitis.

  4. Stability of tacrolimus injection diluted in 0.9% sodium chloride injection and stored in Excel bags.

    Science.gov (United States)

    Myers, Alan L; Zhang, Yanping; Kawedia, Jitesh D; Shank, Brandon R; Deaver, Melissa A; Kramer, Mark A

    2016-12-15

    The chemical stability and physical compatibility of tacrolimus i.v. infusion solutions prepared in Excel bags and stored at 23 or 4 °C for up to nine days were studied. Tacrolimus admixtures (2, 4, and 8 μg/mL) were prepared in Excel bags using 0.9% sodium chloride injection and stored at 23 °C without protection from light or at 4 °C in the dark. Test samples were withdrawn from triplicate bag solutions immediately after preparation and at predetermined time intervals (1, 3, 5, 7, and 9 days). Chemical stability was assessed by measuring tacrolimus concentrations using a validated stability-indicating high-performance liquid chromatography assay. The physical stability of the admixtures was assessed by visual examination and by measuring turbidity, particle size, and drug content. All test solutions stored at 23 or 4 °C had a no greater than 6% loss of the initial tacrolimus concentration throughout the nine-day study period. All test samples of tacrolimus admixtures, under both storage conditions, were without precipitation and remained clear initially and throughout the nine-day observation period. Changes in turbidities were minor; measured particulates remained few in number in all samples throughout the study. Extemporaneously prepared infusion solutions of tacrolimus 2, 4, and 8 μg/mL in 0.9% sodium chloride injection in Excel bags were chemically and physically stable for at least nine days when stored at room temperature (23 °C) without protection from light and when stored in a refrigerator (4 °C) in the dark. Copyright © 2016 by the American Society of Health-System Pharmacists, Inc. All rights reserved.

  5. A model for dry sodium bicarbonate duct injection flue gas desulfurization

    Energy Technology Data Exchange (ETDEWEB)

    Changfa Wu; Soon-Jai Khang; Tim C. Keener; Sang-Kwun Lee [University of Cincinnati, Cincinnati, OH (United States). Department of Chemical Engineering

    2004-03-01

    A mathematical model is developed for simulation of dry sodium bicarbonate (NaHCO{sub 3}) duct injection for the removal of sulfur dioxide (SO{sub 2}) in flue gases across a fabric filter (baghouse). The model employs parallel reaction kinetics and assumes that the sodium bicarbonate injection process can be separated into two stages. The first stage is a transport duct section where NaHCO{sub 3} particles are injected into the sulfur dioxide laden gas stream. The second stage is the fabric filter section where sodium sorbents are collected and behave as a variable depth fixed bed reactor. The process simulation for the efficiency of desulfurization in flue gas is performed and evaluated for a variety of operating conditions. It is found that the removal of SO{sub 2} within the duct section is small and negligible for most practical conditions, with a contribution normally less than 5% of total SO{sub 2} removal. The major removal of SO{sub 2} occurs across the filter cake, which accumulates the sorbent particles on the fabric filter. These particles are periodically disposed as the filter is cleaned. The major factors for the process are temperature, particle size and SO{sub 2} gas concentration for all operating conditions. At low temperatures, the removal of SO{sub 2} increases as temperature increases, but the removal decreases at higher temperatures due to the impact of the thermal decomposition reaction of NaHCO{sub 3} on SO{sub 2} removal. It was found that the temperature for the highest removal of SO{sub 2} is within the range of 127-150{sup o}C and the removal efficiency also depends on particle size.

  6. Compatibility of butorphanol and droperidol in 0.9% sodium chloride injection.

    Science.gov (United States)

    Chen, Fu-Chao; Fang, Bao-Xia; Li, Peng; Yang, Jin-Guo; Zhou, Ben-Hong

    2013-03-15

    The compatibility and stability of butorphanol tartrate and droperidol in polyvinyl chloride (PVC) bags and glass bottles stored at 4°C and 25°C for up to 15 days were studied. Admixtures were assessed initially and for 15 days after preparation in PVC bags and glass bottles using 0.9% sodium chloride injection as a diluent and stored at 4°C and 25°C. The initial drug concentrations were 0.08 mg/mL for butorphanol tartrate and 0.05 mg/mL for droperidol. Samples were withdrawn from each container immediately after preparation and at predetermined intervals (2, 4, 8, 24, 48, 72, 120, 168, 240, and 360 hours after preparation). The solutions were visually inspected for precipitation, cloudiness, and discoloration at each sampling interval. Drug concentrations were determined using a validated high-pressure liquid chromatography method. After 15 days of storage, all formulations tested retained >98% of the initial concentrations of both drugs. The drug mixtures were clear in appearance, and no color change or precipitation was observed. Throughout this period, pH values remained stable. Admixtures of butorphanol tartrate 0.08 mg/mL and droperidol 0.05 mg/mL in 0.9% sodium chloride injection were stable for at least 360 hours when stored in PVC bags or glass bottles at 4°C and 25°C and protected from light.

  7. Association between continuous peripheral i.v. infusion of 3% sodium chloride injection and phlebitis in adults.

    Science.gov (United States)

    Meng, Lina; Nguyen, Cherwyn M; Patel, Samit; Mlynash, Michael; Caulfield, Anna Finley

    2018-03-01

    One institution's experience with use of peripheral i.v. (PIV) catheters for prolonged infusions of 3% sodium chloride injection at rates up to 100 mL/hr is described. A prospective, observational, 13-month quality assurance project was conducted at an academic medical center to evaluate frequencies of patient and catheter phlebitis among adult inpatients who received both an infusion of 3% sodium chloride injection for a period of ≥4 hours through a dedicated PIV catheter and infusions of routine-care solutions (RCSs) through separate PIV catheters during the same hospital stay. Sixty patients received PIV infusions through a total of 291 catheters during the study period. The majority of patients (78%) received infusions of 3% sodium chloride injection for intracranial hypertension, with 30% receiving such infusions in the intensive care unit. Phlebitis occurred in 28 patients (47%) during infusions of 3% sodium chloride and 26 patients (43%) during RCS infusions ( p = 0.19). Catheter phlebitis occurred in 73 catheters (25%), with no significant difference in the frequencies of catheter phlebitis with infusion of 3% sodium chloride versus RCSs (30% [32 of 106 catheters]) versus 22% [41 of 185 catheters]), p = 0.16). Patient and catheter phlebitis rates were not significantly different with infusions of 3% sodium chloride injection versus RCSs, suggesting that an osmolarity cutoff value of 900 mOsm/L for peripheral infusions of hypertonic saline solutions may not be warranted. Copyright © 2018 by the American Society of Health-System Pharmacists, Inc. All rights reserved.

  8. Investigation of the chemical pathway of gaseous nitrogen dioxide formation during flue gas desulfurization with dry sodium bicarbonate injection

    Science.gov (United States)

    Stein, Antoinette Weil

    The chemical reaction pathway for the viable flue gas desulfurization process, dry sodium bicarbonate injection, was investigated to mitigate undesirable plume discoloration. Based on a foundation of past findings, a simplified three-step reaction pathway was hypothesized for the formation of the plume-discoloring constituent, NO2. As the first step, it was hypothesized that sodium sulfite formed by sodium bicarbonate reaction with flue gas SO 2. As the second step, it was hypothesized that sodium nitrate formed by sodium sulfite reaction with flue gas NO. And as the third step, it was hypothesized that NO2 and sodium sulfate formed by sodium nitrate reaction with SO2. The second and third hypothesized steps were experimentally investigated using an isothermal fixed bed reactor. As reported in the past, technical grade sodium sulfite was found to be un-reactive with NO and O2. Freshly prepared sodium sulfite, maintained unexposed to moist air, was shown to react with NO and O2 resulting in a mixture of sodium nitrite and sodium nitrate together with a significant temperature rise. This reaction was found to proceed only when oxygen was present in the flue gas. As reported in the past, technical grade sodium nitrate was shown to be un-reactive with SO2. But freshly formed sodium nitrate kept unexposed to humidity was found to be reactive with SO2 and O 2 resulting in the formation of NO2 and sodium sulfate polymorphic Form I. The NO2 formation by this reaction was shown to be temperature dependent with maximum formation at 175°C. Plume mitigation methods were studied based on the validated three-step reaction pathway. Mitigation of NO2 was exhibited by limiting oxygen concentration in the flue gas to a level below 5%. It was also shown that significant NO2 mitigation was achieved by operating below 110°C or above 250°C. An innovative NO2 mitigation method was patented as a result of the findings of this study. The patented process incorporated a process step of

  9. Experimental Work at Harwell on the Injection of Sodium into Liquid Steel

    International Nuclear Information System (INIS)

    Asher, R.C.; Bradshaw, L.; Collett, R.; Davies, D.

    1976-01-01

    The equipment and experimental technique used to inject molten sodium beneath the surface of molten steel (and subsequently molten uranium dioxide) are described. The results of an exploratory experiment, in which 2 g of sodium at 380 deg. C were injected into 54 g of steel at 1530 deg. C, are outlined. A violent reaction occurred, apparently as a result of a vapour explosion, and a number of pulses were recorded by a force transducer. A preliminary examination of the steel debris is reported. In conclusion: The injection of ∼2 g of sodium at ∼380 deg. C beneath the surface of ∼54 g of steel at 1530 deg. C resulted in a vapour explosion. A series of three pulses (perhaps more) at intervals of ∼6 ms were observed; the peak amplitude was at least 600 N (equivalent to a pressure of ∼20 bar on the base of the crucible). The steel was highly dispersed giving material of predominant particle size ∼500 μ and calculated surface area ∼13.5 cm 2 g -1 ; the particles were almost spherical but some had a small indentation on their surface. The apparatus operated very well, especially considering its rudimentary nature and the speed with which it was assembled. Nevertheless experience of the first experiment showed that many improvements are desirable. (a) Interpretation of the pulses recorded by the force transducer was difficult and would be facilitated by the use of a strong crucible and by a redesigned pillar. (b) Instrumentation on the injector would enable t M and t I to be determined and would permit the injection timing to be related to the pulse record, thus giving a measure of the dwell time. (c) The closed circuit television needs to be linked to a video tape recorder. (d) The recording instrumentation should have a better resolution so that short pulses are not lost or inaccurately recorded; a multichannel tape recorder may be desirable. (e) Direct measurement of the surface area of the debris should be carried out using an existing technique (BET low

  10. Stability of sodium bicarbonate injection 8.4% in syringes over a six-week period in refrigerated temperature.

    Science.gov (United States)

    Seki, Jack T; Wang, Tian Q; Yip, Paul M; Mazzulli, Tony; Minden, Mark D

    2018-04-01

    Background Dysfunctional central venous catheter prohibits the administration of potential life-saving chemotherapy and the delivery of essential supportive care needs to patients. Sodium bicarbonate injection has been shown to impede against fibrin clot formation and prolong prothrombin time and thrombin clotting time. Sodium bicarbonate injection has been tried as a second-line agent with good results in a small number of patients (internal data not published) when alteplase failed. We assessed whether the pre-filled sodium bicarbonate injection in 5 mL syringes would not only preserve sterility and retain its pH and concentration but also amount to the potential cost savings for future use when stored in a refrigerated environment. Methodology Twelve pre-filled 5 mL syringes were prepared aseptically, of which four each were tested for pH, sodium bicarbonate injection concentration and sterility when stored in refrigerated temperature over a six-week period. A standard pH meter, enzymatic carbon dioxide analyzer, and a 14-day incubation for microbial detection were employed for this study. Results Sodium bicarbonate concentration measured in the form of carbon dioxide ranged from 923 mmol/L or (1846 mosol/L) to 1006 mmol/L or (2012 mosmol/L), and pH ranged from (7.88 to 8.05) were reported over the duration of the study period. The 14-day incubation period resulted in no microbial growth. Conclusion Our study results have indicated that the pH and sodium bicarbonate injection concentration values were stable and within range, comparable to those reported by the manufacturer within the study period. The contents of the subdivided sodium bicarbonate injection 5 mL syringes retained sterility over a 14-day incubation period.

  11. Stability of i.v. admixture containing metoclopramide, diphenhydramine hydrochloride, and dexamethasone sodium phosphate in 0.9% sodium chloride injection.

    Science.gov (United States)

    Kintzel, Polly E; Zhao, Ting; Wen, Bo; Sun, Duxin

    2014-12-01

    The chemical stability of a sterile admixture containing metoclopramide 1.6 mg/mL, diphenhydramine hydrochloride 2 mg/mL, and dexamethasone sodium phosphate 0.16 mg/mL in 0.9% sodium chloride injection was evaluated. Triplicate samples were prepared and stored at room temperature without light protection for a total of 48 hours. Aliquots from each sample were tested for chemical stability immediately after preparation and at 1, 4, 8, 24, and 48 hours using liquid chromatography-tandem mass spectrometry (LC-MS/MS) analysis. Metoclopramide, diphenhydramine hydrochloride, and dexamethasone sodium phosphate were selectively monitored using multiple-reaction monitoring. Samples were diluted differently for quantitation using three individual LC-MS/MS methods. To determine the drug concentration of the three compounds in the samples, three calibration curves were constructed by plotting the peak area or the peak area ratio versus the concentration of the calibration standards of each tested compound. Apixaban was used as an internal standard. Linearity of the calibration curve was evaluated by the correlation coefficient r(2). Constituents of the admixture of metoclopramide 1.6 mg/mL, diphenhydramine hydrochloride 2 mg/mL, and dexamethasone sodium phosphate 0.16 mg/mL in 0.9% sodium chloride injection retained more than 90% of their initial concentrations over 48 hours of storage at room temperature without protection from light. The observed variability in concentrations of these three compounds was within the limits of assay variability. An i.v. admixture containing metoclopramide 1.6 mg/mL, diphenhydramine hydrochloride 2 mg/mL, and dexamethasone sodium phosphate 0.16 mg/mL in 0.9% sodium chloride injection was chemically stable for 48 hours when stored at room temperature without light protection. Copyright © 2014 by the American Society of Health-System Pharmacists, Inc. All rights reserved.

  12. [Crosslinking sodium hyaluronate gel with different ratio of molecular weight for subcutaneous injection: animal experimental study and clinical trials subcutaneous injection].

    Science.gov (United States)

    Ran, Weizhi; Wang, Xiaoli; Hu, Yuefei; Gao, Songying; Yang, Yahong; Sun, Jian; Sun, Shuming; Liu, Zhongmei; Wang, Jiangling

    2015-05-01

    To investigate the biocompatibility and degradation rate of crosslinking sodium hyaluronate gel with different ratio of molecular weight, so as to choose the effective, safe and totally degraded hyaluronate gel for aesthetic injection. (1) Compound colloid was formed by cross-linking the divinyl sulphone and sodium hyaluronate with different molecular weight (4 x 10(5), 8 x 10(5), 10 x 10(5), 12 x 10(5)). (2) Healthy level KM mice was randomly divided into two groups to receive hyaluronic acid gel or liquid injection. Each group was subdivided into three subgroup to receive hyaluronic acid with different molecular weight. The biocompatibility and degradation rate, of hyaluronate were observed at 7, 90, 180 days after injection. At the same time, different molecular weight of sodium hyaluronate gel is sealed or exposed respectively under the low temperature preservation to observe its natural degradation rate. (3) The most stable colloid was selected as aesthetic injector for volunteers to observe the aesthetic effect. The sodium hyaluronate gel with molecular of 4 x 10(5) was completely degraded 90 days later. The sodium hyaluronate gel with molecular of 8 x 10(5) was completely degraded 180 days later. The sodium hyaluronate gel with molecular of 10 x 10(5) was degraded to 90.0% after 180 days. The sodium hyaluronate liquid can be degraded completely within 7 days. The colloid could be kept for at least 12 months when sealed under low temperature, but was totally degraded when exposed for I d. Sodium hyaluronate gel with molecular 10 x 10(5) was confirmed to be kept for at least 6 months in animal experiment and clinical trials. Under the same condition of material ratio, the higher the molecular weight is, the lower the degradation rate is. But the liquidity of gel is not good for injection when molecular weight is too large. It suggests that Sodium hyaluronate gel with molecular 10 x 10(5) maybe the best choice in cosmetic injections.

  13. Fabrication of uranium alloy fuel slug for sodium-cooled fast reactor by injection casting

    International Nuclear Information System (INIS)

    Jong Hwan Kim; Hoon Song; Ki Hwan Kim; Chan Bock Lee

    2014-01-01

    Metal fuel slugs of U-Zr alloys for a sodium-cooled fast reactor (SFR) have been fabricated using an injection casting method. However, casting alloys containing volatile radioactive constituents such as Am can cause problems in a conventional injection casting method. Therefore, in this study, several injection-casting methods were applied to evaluate the volatility of the metal-fuel elements and control the transport of volatile elements. Mn was selected as a volatile surrogate alloy since it possesses a total vapor pressure equivalent to that of minor actinide-bearing fuels for SFRs. U-10 wt% Zr and U-10 wt% Zr-5 wt% Mn metal fuels were prepared, and the casting processes were evaluated. The casting soundness of the fuel slugs was characterized by gamma-ray radiography and immersion density measurements. Inductively coupled plasma atomic emission spectroscopy was used to determine the chemical composition of fuel slugs. Fuel losses after casting were also evaluated according to the casting conditions. (author)

  14. In-vitro and in-vivo evaluation of diclofenac sodium intramuscular injection using gamma scintigraphy

    International Nuclear Information System (INIS)

    Soni, S.; Kumar, N.; Mehra, L.; Singh, T.; Mittal, G.; Nishad, D.K.; Sharma, B.G.; Bhatnagar, A.

    2010-01-01

    Full text: Diclofenac is a non-steroidal anti-inflammatory drug (NSAID) which is available as over-the-counter (OTC) medication for the systemic and topical treatment of painful and inflammatory conditions such as arthritis and back pain. This study was undertaken to investigate the distribution and retention of intramuscularly injected diclofenac sodium (DFN) in white New Zealand rabbit using gamma scintigraphy. A new formulation of the nonselective NSAID diclofenac sodium suitable for intramuscular injection has been developed using sesame oil as a vehicle. The hypothesis of present work is to maintain effective concentration of DFN in blood for prolonged time period. A novel method of radiolabeling with 99m Tc-pertechnetate was adopted using stannous ions as reducing agent. The radiolabeled product was tested for quality control using ascending instant thin layer chromatography (ITLC) technique. ITLC-SG, (Gelman, USA) and acetone were used as the stationary phase and mobile phase respectively in the chromatographic procedure. In vitro and in vivo stability parameters were evaluated. Biodistribution studies and blood kinetics of 99m Tc-DFN was done in balb c mice and white New Zealand rabbit respectively. 99m Tc-DFN retention at depot site was evaluated using gamma scintigraphy. 99m Tc-DFN, when incubated at 37 deg C for 24 hr in normal saline and human serum showed disintegration of only 6.6% and 3.5% respectively, thereby indicating high stability of radiolabeled product. Protein binding studies of 99m Tc-DFN shows more than 85% serum protein binding. Blood clearance of radiopharmaceutical in rabbits, exhibited a biphasic exponential pattern in i.v. bolus while in i.m. linear control release pattern were observed up to 24 hrs

  15. The Injection of Sodium into Liquid Stainless Steel: A Report of the Second Experimental Na - SS/1

    International Nuclear Information System (INIS)

    Abbey, M.J.; Asher, R.C.; Bradshaw, L.; Davies, D.; Sangwinw, S.J.

    1976-01-01

    A second experiment in which liquid sodium was injected beneath the surface of molten steel has been carried out using an experimental technique based on that described in AERE - M 2770 but incorporating several improvements particularly in the instrumentation. The sodium (∼1.5 g) was at 400-450 deg. C and the steel (stainless steel in this instance) was at 1750-1800 deg. C. A vapour explosion occurred after a measured dwell time and two force pulses >100 N and 60 N, separated by an interval of ∼1 ms were transmitted to the base of the crucible containing the molten steel. Most of the sodium vapourised' but only a minor part of the steel was converted into small particles. In conclusion: A vapour explosion occurred when ∼1.5 g of sodium at 400-450 deg. C was injected 1.5 cm beneath the surface of molten stainless steel at 1750-1800 deg. C. The explosion occurred 100 N and the second one ∼60 N compared with one pulse of ∼600 N measured in Na/CS/1. Both pulses had a base width of ∼1 ms and the second one a pulse width of ∼500 μs. There was no indication of the prolonged series of pulses observed in Na-CS/1 and which may have been a feature of the equipment used. Virtually all the sodium was vaporised whereas in the previous experiment much of the sodium was recovered as droplets. The steel temperature was > 200 deg. C higher. The steel was on the whole not so finely dispersed; only ∼2% was less than ∼0.5 mm diameter compared with ∼10% in Na-CS/1. Future experiments of this type could be further instrumented; in particular it would be desirable to measure the exact injection rate for each sodium injection and to measure pressure pulses at other points of the equipment

  16. Therapeutic effect of an injectable sustained-release sinomenine hydrochloride and sodium hyaluronate compound in a rabbit model of osteoarthritis.

    Science.gov (United States)

    Liu, Wen-Guang; Ling, Pei-Xue; Lin, Xiu-Kun; Chen, Jian-Ying; Wang, Shao-Jin; Li, Peng; Wu, Xiao-Juan; Zhao, Dong-Mei; Liu, Sheng-Hou

    2012-07-01

    While intra-articular injection of sinomenine hydrochloride has a therapeutic effect on osteoarthritis, it has a short half-life, and is thermolabile and photolabile. The aim of this research was to evaluate the sustained-release of sinomenine hydrochloride from an injectable sinomenine hydrochloride and sodium hyaluronate compound (CSSSI) and its therapeutic effect in a rabbit model of osteoarthritis following intra-articular injection. An injectable compound consisting of 1% sodium hyaluronate and 2.5% sinomenine hydrochloride was prepared and kept as the experiment group, and 2.5% sinomenine hydrochloride was prepared and kept as the control group. The cumulative mass release was measured at different time points in each group in vitro. Sixty-five male Zelanian rabbits were randomly divided into five groups: 15 (30 knees) each for the control, sodium hyaluronate, sinomenine hydrochloride, and CSSSI groups respectively, and five (10 knees) for the modeling group. Papain was injected into both knees of each rabbit for model establishment. Subsequently, 0.2 ml of the corresponding drugs was injected into the articular cavities of the remaining experiment groups, while the control group was treated with 0.2 ml normal saline. All groups were treated once a week for 4 weeks. Seven days after the last treatment, knees were anatomized to perform pathological observations and Mankin's evaluation of the synovium. Four groups were compared using the SPSS 13.0 software package. In the in vitro sustained-release experiments, 90% of the drug was released in the experiment group 360 minutes following the injection. Comparison of the Mankin's evaluations of the four groups illustrated statistical discrepancies (P sodium hyaluronate/sinomenine hydrochloride groups, statistical significance was uniformly obtained. Moreover, sodium hyaluronate and sinomenine hydrochloride treatments showed significant improvement over the modeling control (P sodium hyaluronate vs. sinomenine

  17. Feasibility of simultaneous sodium fluorescein and indocyanine green injection in neurosurgical procedures.

    Science.gov (United States)

    Acerbi, F; Restelli, F; Broggi, M; Schiariti, M; Ferroli, P

    2016-07-01

    The objective of this study is to assess the feasibility of simultaneous Sodium Fluorescein (SF) and Indocyanine Green (ICG) injection during neurosurgical procedures. Three patients harboring a high-grade glioma (HGG) were retrospectively identified in the surgical database of the Neurosurgical Unit 2 at the Foundation IRCCS Istituto Neurologico C. Besta in Milan, by having received intraoperatively both SF for tumor resection and ICG for vasculature angiographic studies in the same surgical procedure. We identified 2 males and 1 female (age range 25-60). Lesions were located in the left temporo-polar area and hippocampus (1 case), right superior frontal gyrus (1 case), left supplementary motor area (1 case). All the three lesions showed Magnetic Resonance Imaging (MRI) characteristics of HGG and, for this reason, in all patients a fluorescein-guided tumor removal was proposed. In the same surgical procedure ICG videoangiography was considered necessary in order to study arterial and venous vasculature, given by the strict relation of the tumor with an unexpected Posterior Communicating Artery (PComA) aneurysm in one case and with cortical drainage veins complexes in the other two cases. In all cases a microscope equipped with both YELLOW560 and IR800 integrated filters (Pentero 900, Carl Zeiss, Oberkorchen, Germany) was used. Fluorescein was i.v. injected at a dose of 5mg/kg immediately after patient intubation. ICG was i.v. injected in bolus on demand of the operating surgeon at a dose of 12.5mg. No side-effects related to simultaneous injection of SF and ICG were identified. In all three cases, the use of SF allowed to better visualize the tumor areas during surgical removal, thus leading to a radical resection until no macroscopic appearance of residual tumor mass and no fluorescence was visible in the surgical cavity. ICG videoangiography confirmed the patency of branches of internal carotid artery after clipping of an unexpected small PComA aneurysm found

  18. Sodium

    Science.gov (United States)

    Table salt is a combination of two minerals - sodium and chloride Your body needs some sodium to work properly. It helps with the function ... in your body. Your kidneys control how much sodium is in your body. If you have too ...

  19. Chemical castration in cattle with intratesticular injection of sodium chloride: Effects on stress and inflammatory markers.

    Science.gov (United States)

    Oliveira, Fernando C; Ferreira, Carlos E R; Haas, Cristina S; Oliveira, Leonardo G; Mondadori, Rafael G; Schneider, Augusto; Rovani, Monique T; Gonçalves, Paulo B D; Vieira, Arnaldo D; Gasperin, Bernardo G; Lucia, Thomaz

    2017-03-01

    Intratesticular injection (ITI) of sodium chloride (NaCl) is efficient for chemical castration of young calves, but its effects on calves welfare are unknown. Two experiments were conducted to evaluate the effects of ITI of 20% NaCl on stress and inflammatory markers in calves less than 20 days old and to assess the efficiency of ITI of 30% NaCl in 5 months old calves. In Experiment 1, control calves were only restrained and compared to calves submitted to castration through surgery (SC) and ITI with 20% NaCl (n = 9/group). No differences were observed for the eye corner temperature measured by thermography from 60 s before to 60 s after the procedures (P > 0.05). In the SC group, acute serum cortisol levels increased at 30 and 60 min after the procedure, but increased levels in the ITI group occurred only at 30 min (P  0.05). Scrotal temperature was higher at D1 in the SC group than for the other groups, but lowest at D4 compared to the control (both P castration through ITI of 20% NaCl in young calves was followed by slight stress and inflammatory responses compared to surgical castration. However, ITI of 30% NaCl was ineffective for chemical castration of 5 months old calves. Copyright © 2016 Elsevier Inc. All rights reserved.

  20. Nephrotic syndrome induced by dibasic sodium phosphate injections for twenty-eight days in rats.

    Science.gov (United States)

    Tsuchiya, Noriko; Torii, Mikinori; Narama, Isao; Matsui, Takane

    2009-04-01

    Sprague-Dawley rats received once daily tail-vein injections of 360 mM dibasic sodium phosphate solution at 8 mL/kg for fourteen or twenty-eight days. Clinical examination revealed persistent proteinuria from three days after the first dosing and thereafter severe proteinuria from eight days or later in the phosphate-treated groups. Proteinuria developed without remission even after fourteen-day withdrawal in the fourteen-day dosed group. Phosphate-treated animals developed lipemia, hypercholesterolemia, anemia, higher serum fibrinogen levels, and lower serum albumin/globulin ratios on day 29. Renal weight increased significantly compared with control animals, and the kidneys appeared pale and enlarged with a rough surface. Histopathologically, glomerular changes consisted of mineralization in whole glomeruli, glomerular capillary dilatation, partial adhesion of glomerular tufts to Bowman's capsule, and mesangiolysis. Ultrastructural lesions such as an increased number of microvilli, effacement of foot processes, and thickening of the glomerular basement membrane, and immunocytochemical changes in podocytes, mainly decreased podoplanin-positive cells and increased desmin expression, were also conspicuous in the phosphate-treated rats for twenty-eight days. Marked tubulointerstitial lesions were tubular regeneration and dilatation, protein casts, mineralization in the basement membrane, focal interstitial inflammation, and fibrosis in the cortex. These clinical and morphological changes were similar to features of human nephrotic syndrome.

  1. Compatibility and Stability of Rolapitant Injectable Emulsion Admixed with Dexamethasone Sodium Phosphate.

    Science.gov (United States)

    Wu, George; Yeung, Stanley; Chen, Frank

    2017-01-01

    Neurokinin-1 receptor antagonist, 5-hydroxytryptamine-3 receptor antagonist, and dexamethasone combination therapy is the standard of care for the prevention of chemotherapy-induced nausea and vomiting. Herein, we describe the physical and chemical stability of an injectable emulsion of the Neurokinin-1 receptor antagonist rolapitant 185 mg in 92.5 mL (free base, 166.5 mg in 92.5 mL) admixed with either 2.5 mL of dexamethasone sodium phosphate (10 mg) or 5 mL of dexamethasone sodium phosphate (20 mg). Admixtures were prepared and stored in two types of container closures (glass and Crystal Zenith plastic bottles) and four types of intravenous administration tubing sets (or intravenous tubing sets). The assessment of the physical and chemical stability was conducted on admixtures packaged in bottled samples stored at room temperature (20°C to 25°C under fluorescent light) and evaluated at 0, 1, and 6 hours. For admixtures in intravenous tubing sets, the assessment of physicochemical stability was performed after 0 and 7 hours of storage at 20°C to 25°C, and then after 20 hours (total 27 hours) under refrigeration (2°C to 8°C) and protected from light. Physical stability was assessed by visually examining the bottle contents under normal room light and measuring turbidity and particulate matter. Chemical stability was assessed by measuring the pH of the admixture and determining drug concentrations through high-performance liquid chromatographic analysis. Results showed that all samples were physically compatible throughout the duration of the study. The admixtures stayed within narrow and acceptable ranges in pH, turbidity, and particulate matter. Admixtures of rolapitant and dexamethasone were chemically stable when stored in glass and Crystal Zenith bottles for at least 6 hours at room temperature, as well as in the four selected intravenous tubing sets for 7 hours at 20°C to 25°C and then for 20 (total 27 hours) hours at 2°C to 8°C. No loss of potency

  2. Stability of methadone hydrochloride in 0.9% sodium chloride injection in single-dose plastic containers.

    Science.gov (United States)

    Denson, D D; Crews, J C; Grummich, K W; Stirm, E J; Sue, C A

    1991-03-01

    The stability of methadone hydrochloride in 0.9% sodium chloride injection in flexible polyvinyl chloride containers was studied. Commercially available methadone hydrochloride 20 mg/mL and 25-mL single-dose bags of 0.9% sodium chloride injection were used. Six samples each were prepared at methadone hydrochloride concentrations of 1, 2, and 5 mg/mL. The solutions were stored at room temperature and were not protected from light. Immediately after preparation and after two, three, and four weeks of storage, each of the 18 samples was divided into three aliquots, each of which was analyzed in duplicate for methadone hydrochloride concentration by gas chromatography. There was less than 10% change in methadone hydrochloride concentration in any sample throughout the four-week study period. Methadone hydrochloride at concentrations of 1, 2, and 5 mg/mL prepared in commercially available flexible polyvinyl chloride containers of 0.9% sodium chloride injection and stored at room temperature without deliberate protection from light is stable for at least four weeks.

  3. Effectiveness of intra-articular injections of sodium hyaluronate-chondroitin sulfate in knee osteoarthritis: a multicenter prospective study.

    Science.gov (United States)

    Rivera, Fabrizio; Bertignone, Luca; Grandi, Giancarlo; Camisassa, Roberto; Comaschi, Guido; Trentini, Diego; Zanone, Marco; Teppex, Giuseppe; Vasario, Gabriele; Fortina, Giorgio

    2016-03-01

    Intra-articular injection of hyaluronic acid is a well-established therapy for the treatment of knee osteoarthritis. The aim of the study was to assess the effectiveness and safety of the use of Arthrum HCS(®) (40 mg hyaluronic acid and 40 mg chondroitin sulfate in 2 mL). This was an open, multicenter, prospective study. Men or women over 40 years of age with documented knee osteoarthritis and WOMAC subscore A (severity of pain) ≥25 were enrolled. They received three weekly intra-articular injections of sodium hyaluronate 2 % and chondroitin sulfate 2 % in combination. WOMAC subscore A was assessed at 1, 3 and 6 months after the last injection. One hundred and twelve patients were included (women, 66 %). The mean (SD) WOMAC subscore A decreased from 52.1 (15.2) at inclusion to 20.5 (19.7) at month 6 (P chondroitin sulfate in reducing pain (77 %), improving mobility (78 %) and reducing the consumption of analgesics (74 %). Only one adverse effect was reported by one patient (knee tumefaction). These results suggest that intra-articular injections of Arthrum HCS(®) (sodium hyaluronate plus chondroitin sulfate) in patients with knee osteoarthritis are efficient and safe. These results should be confirmed in a randomized controlled study. IV.

  4. Experiments on the behaviour of thermite melt injected into sodium: Final report on the THINA test results

    International Nuclear Information System (INIS)

    Huber, F.; Kaiser, A.; Peppler, W.

    1994-01-01

    During hypothetical accidents of fast breeder reactors the core melts and part of the core material inventory is ejected into the upper coolant plenum. As a consequence, a fuel to coolant thermal interaction occurs between the melt and the sodium. A series of simulating experiments was carried out in KfK/IRS to improve the knowledge about the phenomenology of molten fuel/coolant interactions and to support theoretical work on the safety of fast breeder reactors. In the tests, a thermite melt of up to 3270 K is injected from below into a sodium pool the temperature of which is between 770 and 820 K. The masses of the melt and the sodium are about five and 150 kg, respectively. Thermal interactions have been observed to occur as a sequence of small local pressure events mainly during the melt injection. Large-scale vapour explosions have not been observed. Generally, the conversion ratios of thermal to mechanical energy have been low. (author)

  5. Heat transfer characteristics around a single heated rod immersed in sodium pool with gas jet injection

    International Nuclear Information System (INIS)

    Hideto Niikura; Kazuo Soga; Ken-ichiro Sugiyama; Akira Yamaguchi

    2005-01-01

    In a steam generator using liquid sodium, water intensely reacts with sodium when it leaks out from a heat transfer tube. It is important to evaluate the influence of sodium-water reaction to surrounding tubes and the shell. Hence, it has been desired to develop the simulation code for the evaluation of sodium-water reaction. From this viewpoint, the Japan Nuclear Cycle is now developing the SERAPHIM code. We reported a preliminary study to establish an experimental method for a single heated rod immersed in sodium pool with steam jet impingement planned in the near future as well as to obtain a preliminary data to verify the adequacy of SERAPHIM code. We first measured local and mean heat transfer coefficients around a horizontal single heated rod immersed in a water pool and a sodium pool with a limited volume in the experimental apparatus. It was confirmed that the mean heat transfer coefficients fairly agreed with the existing data for natural convection in water and sodium. Secondary we measured local and mean heat transfer coefficients around a horizontal single heated rod with Ar gas jet impingement immersed in the limited water pool and in the limited sodium pool. It was clearly observed that the local heat transfer coefficients in the sodium pool keep almost the same values in every angle regardless of increase in Ar gas jet velocity varied from about 8.7m/s to about 78m/s. On the other hand, it was confirmed in the water pool that local heat transfer coefficients on the forward stagnation side exposed in the Ar gas jet impingement increase with increasing the jet velocity while the local heat transfer coefficients on the opposite surface keep almost same values regardless of increase in the velocity. (authors)

  6. sodium

    International Development Research Centre (IDRC) Digital Library (Canada)

    Les initiatives de réduction de la consommation de sel qui visent l'ensemble de la population et qui ciblent la teneur en sodium des aliments et sensibilisent les consommateurs sont susceptibles de réduire la consommation de sel dans toutes les couches de la population et d'améliorer la santé cardiovasculaire. Ce projet a ...

  7. Effect of gamma radiation on glucose and sodium chloride solutions for injection

    International Nuclear Information System (INIS)

    Lakoza, G.N.; Grigor'eva, O.L.; Mart'yanova, B.M.; Vorob'eva, E.N.; Kuznetsova, R.M.

    1976-01-01

    Irradiation of 40% glucose solution with 0.5-4.0 Mrads di not affect the detoxicating properties of glucose or its ability to raise blood sugar levels. Such doses had no effect on the toxicological properties of 40% glucose solution and on 0.9% sodium chloride solution. The biological and physicochemical properties of 40% solution and 0.9% sodium chloride solutions irradiated with sterilizing doses showed no significant alterations during storage for one and three years, respectively. It is concluded that the solutions studied may be sterilized by radiation. (auth.)

  8. Histological changes to the skin of Merino sheep following deep dermal and subcutaneous injections of sodium lauryl sulfate.

    Science.gov (United States)

    Lee, E J; Rothwell, J T

    2010-04-01

    To characterise the changes caused to sheep skin by deep dermal and subcutaneous injections of sodium lauryl sulfate (SLS) and describe the subsequent healing process. On 6 sheep 20 small areas of skin were each given deep dermal and subcutaneous injections of 0.2 mL of 7% SLS. Biopsies were collected at intervals up to 28 days after treatment and the histological changes in each of the treated skin samples were assessed and graded. There was no evidence of alterations in behaviour, weight gain or appetite of the sheep following the injections. Initial swelling of the treated site subsided by day 14, leaving a firm, slightly raised crust. At day 21, the treated area was depressed and covered by a scab, which sloughed completely by day 28. There was necrosis of the subcutis and deep dermis 2 min after treatment, followed by inflammation, fibroplasia, angiogenesis and tissue remodelling. Injection of SLS caused almost immediate local necrosis followed by eschar formation, sloughing and scarring of treated skin. Deep dermal and subcutaneous SLS is potentially useful as a chemical alternative to mulesing.

  9. Metabolomics of the aqueous humor in the rat glaucoma model induced by a series of intracamerular sodium hyaluronate injection.

    Science.gov (United States)

    Mayordomo-Febrer, A; López-Murcia, M; Morales-Tatay, J M; Monleón-Salvado, D; Pinazo-Durán, M D

    2015-02-01

    Glaucoma models are helpful to study disease characteristics and to design new therapeutic options. Metabolomic profiling approach have been used to elucidating the molecular characteristics of the aqueous humor. Juvenile male Wistar rats experimental (n = 15) and controls (n = 6) were used for these studies. Experimental rats received weekly intracamerular injection of 25 µl of sodium hyaluronate in the left eye and sterile saline solution in the right eye, consecutively for ten weeks. Rats were subjected to anterior/posterior eye segment examinations, intraocular pressure (IOP), and flash electroretinograms (ERG). The aqueous humor was collected at endpoints and analyzed by Nuclear Magnetic Resonance. Elevated IOP and significant reduction of a, b waves and amplitude of oscillatory potential was observed in the left eyes compared to control eyes. The aqueous humor metabolomic profile from control and the experimental eyes were compared. Concentrations of metabolites (amino acids, lipids and carbohydrates) significantly changed after the sodium hyaluronate injections series, compared to the sham-operated eyes. Metabolic changes in the hypertensive eyes correlated with the impaired retinal function. Observed metabolomic changes in aqueous humor in hypertensive state may play a significant role in glaucoma pathogenesis. Copyright © 2014 Elsevier Ltd. All rights reserved.

  10. Injectable nanoparticle-loaded hydrogel system for local delivery of sodium alendronate

    Czech Academy of Sciences Publication Activity Database

    Posadowska, U.; Pařízek, Martin; Filová, Elena; Wlodarczyk-Biegun, M.; Kamperman, M.; Bačáková, Lucie; Pamula, E.

    2015-01-01

    Roč. 485, 1-2 (2015), s. 31-40 ISSN 0378-5173 R&D Projects: GA MZd(CZ) NT13297 Institutional support: RVO:67985823 Keywords : sodium alendronate * PLGA * nanoparticles Subject RIV: EI - Biotechnology ; Bionics Impact factor: 3.994, year: 2015

  11. Pain control in laparoscopic gynecologic surgery with/without preoperative (preemptive) parecoxib sodium injection: a randomized study.

    Science.gov (United States)

    Ratchanon, Sarwinee; Phaloprakarn, Chadakarn; Traipak, Khanitta

    2011-10-01

    To determine the effectiveness of preoperative parecoxib sodium injection for pain relief after laparoscopic gynecologic surgery. A prospective double-blind, randomized study was conducted in 268 patients who underwent laparoscopic gynecologic surgery at Vajira Hospital between November 1, 2010 and March 31, 2011. The patients were randomly allocated into two groups to receive either single intravenous 40 mg parecoxib (treatment group; n = 133) or normal saline (control group; n = 135) 30 min before surgery. The degree of postoperative pain was assessed every 2 h in the first 8 h postoperation, then every 4 h until completion of 24 h by using a verbal rating scale. Total consumption of meperidine over a 24-h period and the adverse events relevant to parecoxib sodium were also recorded. Mean pain scores at all measured times in the treatment group were insignificantly lower than those in the control group (p = 0.106). The mean 24-h postoperative meperidine consumption in the treatment group was significantly lower compared to that in the control group (26.3 +/- 28.1 mg and 39.1 +/- 34.6 mg, respectively, p = 0.001). The proportion of patients requiring meperidine in the treatment group was significantly lower than that in the control group (58.6% and 70.3%, respectively, p = 0. 045). No serious adverse events were observed in both groups. Preoperative parecoxib sodium significantly reduced postoperative meperidine requirement and consumption, while insignificantly declined the pain scores. Serious adverse events were not encountered

  12. Comparative Evaluation of U.S. Brand and Generic Intravenous Sodium Ferric Gluconate Complex in Sucrose Injection: Physicochemical Characterization

    Directory of Open Access Journals (Sweden)

    Dajun Sun

    2018-01-01

    Full Text Available The objective of this study was to evaluate physicochemical equivalence between brand (i.e., Ferrlecit and generic sodium ferric gluconate (SFG in sucrose injection by conducting a series of comparative in vitro characterizations using advanced analytical techniques. The elemental iron and carbon content, thermal properties, viscosity, particle size, zeta potential, sedimentation coefficient, and molecular weight were determined. There was no noticeable difference between brand and generic SFG in sucrose injection for the above physical parameters evaluated, except for the sedimentation coefficient determined by sedimentation velocity analytical ultracentrifugation (SV-AUC and molecular weight by asymmetric field flow fractionation-multi-angle light scattering (AFFF-MALS. In addition, brand and generic SFG complex products showed comparable molecular weight distributions when determined by gel permeation chromatography (GPC. The observed minor differences between brand and generic SFG, such as sedimentation coefficient, do not impact their biological activities in separate studies of in vitro cellular uptake and rat biodistribution. Coupled with the ongoing clinical study comparing the labile iron level in healthy volunteers, the FDA-funded post-market studies intended to illustrate comprehensive surveillance efforts ensuring safety and efficacy profiles of generic SFG complex in sucrose injection, and also to shed new light on the approval standards on generic parenteral iron colloidal products.

  13. A validated stability indicating high-performance liquid chromatographic method for simultaneous estimation of cefuroxime sodium and sulbactam sodium in injection dosage form

    Directory of Open Access Journals (Sweden)

    Falguni M Patel

    2012-01-01

    Full Text Available Background: A fixed dose combination of cefuroxime sodium (β lactam antibiotic and sulbactam sodium (β Lactamase inhibitor is used in ratio of 2:1 as powder for injection for the treatment of resistant lower respiratory tract and other infections. Aims: A simple, precise, and accurate ion-pair reverse-phase high-performance liquid chromatography (RP-HPLC method was developed and validated for determination of cefuroxime Na(CEF and sulbactam Na(SUL in injection. Materials and Methods: Isocratic RP-HPLC separation was achieved on an ACE C 18 column (150×4.6 mm id, 5 μm particle size using the mobile phase 0.002 M tetrabutylammonium hydroxide sulfate (TBAH in 10 mm potassium di-hydrogen phosphate buffer-acetonitrile (86:14 v/v, pH 3.7 at a flow rate of 1.0 ml/min. Results and Conclusion: The retention time of sulbactam Na and cefuroxime Na were 3.2 min and 10.2 min, respectively. The ion-pairing reagent improved the retention of highly polar sulbactam Na on reverse-phase column. The detection was performed at 210 nm. The method was validated for linearity, precision, accuracy, robustness, solution stability, and specificity. The method was validated for linearity, precision, accuracy, robustness, solution stability, and specificity. The method was linear in the concentration range of 10-100 μg/ml for cefuroxime Na and 5-50 μg/ml for sulbactam Na, with a correlation coefficient of 0.9999 and 0.9998 for the respective drugs. The intraday precision was 0.13-0.21% and 0.48-0.65%, and the interday precision was 0.32-0.81% and 0.60-0.83% for cefuroxime Na and sulbactam Na, respectively. The accuracy (recovery was found to be in the range of 98.76-100.61% and 98.99-100.30% for cefuroxime Na and sulbactam Na, respectively. The drugs were found to degrade under hydrolytic and oxidative conditions. The drugs could be effectively separated from different degradation products, and hence the method can be used for stability analysis.

  14. 21 CFR 522.563 - Diatrizoate meglumine and diatrizoate sodium injection.

    Science.gov (United States)

    2010-04-01

    ...) Conditions of use. (1) It is indicated for use in dogs and cats for visualization in excretion urography... hernias and fistulous tracts. (2) For excretion urography administer 0.5 to 1.0 milliliter per pound of... tract. For delineation of peritoneal hernias inject 0.5 to 1.0 milliliter per pound of body weight...

  15. Effect of pegaptanib sodium 0.3 mg intravitreal injections (Macugen) in intraocular pressure

    DEFF Research Database (Denmark)

    Boyer, David S; Goldbaum, Mauro; Leys, Anita M

    2014-01-01

    OBJECTIVE: To assess the rate of pegaptanib-associated sustained intraocular pressure (IOP) elevation. METHODS: A posthoc analysis was conducted on all IOP measurements, except the immediate 30-min postinjection, from all subjects randomised to pegaptanib 0.3 mg or sham injections continuously in...

  16. Phase characteristics of rare earth elements in metallic fuel for a sodium-cooled fast reactor by injection casting

    Energy Technology Data Exchange (ETDEWEB)

    Kuk, Seoung Woo, E-mail: swkuk@kaeri.re.kr [Next Generation Fuel Development Division, Korea Atomic Energy Research Institute, Daedeok-daero 989-111, Yuseong-gu, Daejeon, 34057 (Korea, Republic of); Kim, Ki Hwan; Kim, Jong Hwan; Song, Hoon; Oh, Seok Jin; Park, Jeong-Yong; Lee, Chan Bock [Next Generation Fuel Development Division, Korea Atomic Energy Research Institute, Daedeok-daero 989-111, Yuseong-gu, Daejeon, 34057 (Korea, Republic of); Youn, Young-Sang [Nuclear Chemistry Research Division, Korea Atomic Energy Research Institute, Daedeok-daero 989-111, Yuseong-gu, Daejeon, 34057 (Korea, Republic of); Kim, Jong-Yun [Nuclear Chemistry Research Division, Korea Atomic Energy Research Institute, Daedeok-daero 989-111, Yuseong-gu, Daejeon, 34057 (Korea, Republic of); Radiochemistry & Nuclear Nonproliferation, University of Science & Technology, Gajeong-ro 217, Yuseong-gu, Daejeon, 34113 (Korea, Republic of)

    2017-04-01

    Uranium-zirconium-rare earth (U-Zr-RE) fuel slugs for a sodium-cooled fast reactor were manufactured using a modified injection casting method, and investigated with respect to their uniformity, distribution, composition, and phase behavior according to RE content. Nd, Ce, Pr, and La were chosen as four representative lanthanide elements because they are considered to be major RE components of fuel ingots after pyroprocessing. Immiscible layers were found on the top layers of the melt-residue commensurate with higher fuel slug RE content. Scanning electron microscopy-energy-dispersive X-ray spectroscopy (SEM-EDS) data showed that RE elements in the melt-residue were distributed uniformly throughout the fuel slugs. RE element agglomeration did not contaminate the fuel slugs but strongly affected the RE content of the slugs.

  17. Compatibility of butorphanol with granisetron in 0.9% sodium chloride injection packaged in glass bottles or polyolefin bags.

    Science.gov (United States)

    Chen, Fu-Chao; Xiong, Hui; Liu, Hui-Min; Fang, Bao-Xia; Li, Peng

    2015-08-15

    The stability of admixtures containing butorphanol and granisetron in polyolefin bags and glass bottles stored at 4 and 25 °C was studied. Commercial solutions of butorphanol tartrate and granisetron hydrochloride were combined and further diluted with 0.9% sodium chloride injection to final concentrations of butorphanol tartrate 0.08 mg/mL and granisetron 0.03 or 0.06 mg/mL; the resulting mixtures were packaged in polyolefin bags and glass bottles. The admixtures were assessed for periods of up to 48 hours after storage at 25 °C without protection from room light and up to 14 days at 4 °C with protection from room light. The chemical stability of the admixtures was evaluated by a validated high-performance liquid chromatography (HPLC) method and by measurement of pH values. Solution appearance and color were assessed by observing the samples against room light and dark backgrounds. HPLC analysis demonstrated that the percentages of the initial concentrations of butorphanol and granisetron in the various solutions remained above 97% during the testing period. No changes in color or turbidity were observed in any of the prepared solutions. Throughout this period, pH values remained stable. Admixtures of butorphanol tartrate 0.08 mg/mL and granisetron 0.03 or 0.06 mg/mL in 0.9% sodium chloride injection in polyolefin bags or glass bottles remained stable for 48 hours when stored at 25 °C exposed to room light and for 14 days when stored at 4 °C protected from room light. Copyright © 2015 by the American Society of Health-System Pharmacists, Inc. All rights reserved.

  18. Stability of polymyxin B sulfate diluted in 0.9% sodium chloride injection and stored at 4 or 25 degrees C.

    Science.gov (United States)

    He, Jie; Figueroa, Deborah A; Lim, Tze-Peng; Chow, Diana S; Tam, Vincent H

    2010-07-15

    The stability of polymyxin B sulfate in infusion bags containing 0.9% sodium chloride injection stored at 4 and 25 degrees C was studied. Seven manufacturing batches of polymyxin B from different sources were tested. The products were reconstituted in sterile water for injection, diluted in infusion bags containing 0.9% sodium chloride injection, and stored at room temperature (25 degrees C) or under refrigeration (4 degrees C). Samples were withdrawn at the same time on days 0, 1, 2, 3, 5, and 7. A modified microbiological assay was used to determine the concentrations, as indicated by zones of inhibition, of polymyxin B. Bordetella bronchiseptica served as the reference organism. Stability was defined as retention of >90% of the initial concentration. The decomposition kinetics of polymyxin B in 0.9% sodium chloride injection were evaluated by plotting the polymyxin B concentration remaining versus time. On average, the samples retained over 90% of their initial concentration for up to two days at both storage temperatures. All samples retained over 90% of their initial concentration at 24 hours. The decomposition kinetics of polymyxin B in infusion bags containing 0.9% sodium chloride injection exhibited pseudo-first-order kinetics, with rate constants of 0.024-0.075 day(-1) at 25 degrees C and 0.022-0.043 day(-1) at 4 degrees C (p > 0.05). Polymyxin B was stable for at least one day when stored at 4 or 25 degrees C in infusion bags containing 0.9% sodium chloride injection. Stability did not differ significantly between the two storage temperatures.

  19. Evaluation of calcium di-sodium EDTA intramuscular injection using gamma scintigraphy against heavy metal poisoning

    International Nuclear Information System (INIS)

    Kumar, N.; Soni, S.; Mehra, L.; Mittal, G.; Nishad, D.K.; Bhatnagar, A.; Singh, T.; Ahmad, F.J.

    2010-01-01

    Full text: Heavy metals become toxic when they are not metabolized by the body and accumulate in soft tissues. These metals may enter the body through food, water, air or absorption through skin when an individual is exposed to areas with high heavy metal content such as agriculture, pharmaceutical manufacturing, paint and heavy metal industries or residential settings. Majority of population commonly get affected by heavy metal poisoning. Heavy metal poisoning is more likely to result through inhalation or ingestion route. Aim of the present study is to provide an easy, effective and controlled chelating therapy against heavy metal using Ca-disodium EDTA intramuscular injection. Ca-disodium-EDTA and Sesame oil were procured from Merck, India and Sigma Aldrich, USA respectively. Ca-Na 2 EDTA radiolabeling with 99m Tc-pertechnetate was standardized using stannous ions as reducing agent. The hypothesis of present work is to maintain effective concentration of chelating agent in blood for prolong time period. To test this hypothesis, we studied 1% Ca-Na 2 EDTA blood bioavailability after intramuscular depot administration in new zealand white rabbit. The optimized radiolabeled intramuscular formulation was evaluated for its dissolution and permeation studies in isotonic buffer solution were envisaged through radiometry. Sub-acute toxicity studies were performed after a single dose intramuscular administration of 1% Ca-Na 2 EDTA in Sprague Dawley rats. Radiolabeled Ca-disodium-EDTA (>95% labeled) was found to be fairly stable up to 24 h in physiological solution (Serum) as well as in normal saline with negligible degradation of 2.5% and 5.0% respectively, thereby indicating high stability of radiolabeled product. In-vitro data indicates that control release pattern (Cmax 24 hrs) with effective concentration up to seven days. 99m Tc-CaNa 2 EDTA retention at depot site was estimated up to 3 days by scintigraphy. Subacute toxicity studies done by histopathological

  20. Review of fondaparinux sodium injection for the prevention of venous thromboembolism in patients undergoing surgery

    Directory of Open Access Journals (Sweden)

    David Bergqvist

    2006-12-01

    Full Text Available David BergqvistDepartment of Surgery, University Hospital, Uppsala, SwedenAbstract: The antithrombin binding sequence of heparin, a pentasaccharide, has been synthesized as fondaparinux, an indirect, selective, and reversible factor Xa inhibitor. It can be administered subcutaneously, is well absorbed, and has a half-life of c. 17 hours permitting once-daily injection. It has been evaluated in an extensive study program in major orthopedic surgery, including hip fracture, and in major abdominal surgery with a large proportion of surgery for cancer. The effect is at least as effective as for low-molecular-weight heparins and it has also been shown effective for extended prophylaxis in hip fracture patients. Several thousands of patients have been studied and the substance is safe, although a slightly higher frequency of bleedings is found than in patients on low-molecular-weight heparins. There is no specific antidote but if necessary, recombinant activated factor VII can be used. Other side-effects are rare. Fondaparinux is cost saving and sometimes cost neutral when compared with enoxaparin. Keywords: fondaparinux, venous thrombosis, venous thromboembolism, surgery, orthopedic surgery, major abdominal surgery, bleeding complications

  1. Validation of a stability-indicating hydrophilic interaction liquid chromatographic method for the quantitative determination of vitamin k3 (menadione sodium bisulfite) in injectable solution formulation.

    Science.gov (United States)

    Ghanem, Mashhour M; Abu-Lafi, Saleh A; Hallak, Hussein O

    2013-01-01

    A simple, specific, accurate, and stability-indicating method was developed and validated for the quantitative determination of menadione sodium bisulfite in the injectable solution formulation. The method is based on zwitterionic hydrophilic interaction liquid chromatography (ZIC-HILIC) coupled with a photodiode array detector. The desired separation was achieved on the ZIC-HILIC column (250 mm × 4.6 mm, 5 μm) at 25°C temperature. The optimized mobile phase consisted of an isocratic solvent mixture of 200mM ammonium acetate (NH4AC) solution and acetonitrile (ACN) (20:80; v/v) pH-adjusted to 5.7 by glacial acetic acid. The mobile phase was fixed at 0.5 ml/min and the analytes were monitored at 261 nm using a photodiode array detector. The effects of the chromatographic conditions on the peak retention, peak USP tailing factor, and column efficiency were systematically optimized. Forced degradation experiments were carried out by exposing menadione sodium bisulfite standard and the injectable solution formulation to thermal, photolytic, oxidative, and acid-base hydrolytic stress conditions. The degradation products were well-resolved from the main peak and the excipients, thus proving that the method is a reliable, stability-indicating tool. The method was validated as per ICH and USP guidelines (USP34/NF29) and found to be adequate for the routine quantitative estimation of menadione sodium bisulfite in commercially available menadione sodium bisulfite injectable solution dosage forms.

  2. Clinical evaluation of sodium hyaluronate in the treatment of patients with sopraspinatus tendinosis under echographic guide: Experimental study of periarticular injections

    International Nuclear Information System (INIS)

    Meloni, F.; Milia, F.; Cavazzuti, M.; Doria, C.; Lisai, P.; Profili, S.; Meloni, G.B.

    2008-01-01

    Purpose: The purpose of this study was to examine the effect of periarticular injection of hyaluronate into shoulders with supraspinatus tendinosis under echographic guide. Methods and materials: The subjects were 56 patients with clinical, echographic and magnetic resonance diagnosis of supraspinatus tendinosis. They were divided in two groups by random sampling; 28 patients were assigned in SH group (sodium hyaluronate) and 28 patients in SC group (sodium chloride). The test drug was 20 mg sodium hyaluronate (2 ml, Hyalgan, Fidia SpA, Abano T., P.M. 500-700.000, 20 mg/2 ml). Results: Preliminary results showed that sodium hyaluronate presented the highest efficacy in the improvement of clinical symptoms and recovery of functional status in patients with supraspinatus tendinosis in fact the mean V.A.S. score (Visual Analogue Scale) at 1 month after the end of the infiltrative cycle was 8.0 in the SC group vs. 2.8 in SH group and these numerical data were substantially unchanged also after 3 and 4 months. Conclusion: Hyaluronate injection under echographic guide should be use not only as a lubricant but also to prevent articular cartilage degeneration and cover and protect the articular cartilage; indeed sodium hyaluronate can decrease inflammatory joint process

  3. Sodium hydroxide injection passivation work for the reactor water clean-up system in a new ABWR plant

    International Nuclear Information System (INIS)

    Wen, Tung-Jen; Lu, Ju-Huang

    2012-09-01

    Several studies have identified that Co-58 and Co-60 as the primary source of radiation build up on out-of-core components in new BWR plants. The deposition rate of Co on stainless steel and carbon steel is shown to be controlled mainly by the thickness of oxide films and its morphology formed through pretreatment. The passivation treatment was implemented accordingly at Lungmen unit 1 in an ABWR plant in September 2010. It is determined that the passivation conditions should be maintained at the temperature of 180∼230 deg. C, pH of 8.0∼8.5 and dissolved oxygen content over 400 ppb. The films would provide effective protection against radioactive deposition. The application of the pre-filming process on piping before the pre-operation is done during the flow induced vibration test (FIV) period. The protectiveness of stable magnetite can be increased by the pH control under the specific condition. The pre-filming control process and evaluation of passivation effectiveness is discussed in detail based on the surface analysis of the passivated specimens. Many efforts have been devoted to sodium hydroxide injection method for pH control of the system through the filter demineralizer under smooth operation. A comparison of test specimens on the properties of oxide film formed between laboratory and in-plant tests through alkaline treatment are also shown in this report. (authors)

  4. Role of angiotensin II and vasopressin receptors within the supraoptic nucleus in water and sodium intake induced by the injection of angiotensin II into the medial septal area

    Directory of Open Access Journals (Sweden)

    Antunes V.R.

    1998-01-01

    Full Text Available In this study we investigated the effects of the injection into the supraoptic nucleus (SON of non-peptide AT1- and AT2-angiotensin II (ANG II receptor antagonists, DuP753 and PD123319, as well as of the arginine-vasopressin (AVP receptor antagonist d(CH25-Tyr(Me-AVP, on water and 3% NaCl intake induced by the injection of ANG II into the medial septal area (MSA. The effects on water or 3% NaCl intake were assessed in 30-h water-deprived or in 20-h water-deprived furosemide-treated adult male rats, respectively. The drugs were injected in 0.5 ml over 30-60 s. Controls were injected with a similar volume of 0.15 M NaCl. Antagonists were injected at doses of 20, 80 and 180 nmol. Water and sodium intake was measured over a 2-h period. Previous administration of the AT1 receptor antagonist DuP753 into the SON decreased water (65%, N = 10, P<0.01 and sodium intake (81%, N = 8, P<0.01 induced by the injection of ANG II (10 nmol into the MSA. Neither of these responses was significantly changed by injection of the AT2-receptor antagonist PD123319 into the SON. On the other hand, while there was a decrease in water intake (45%, N = 9, P<0.01, ANG II-induced sodium intake was significantly increased (70%, N = 8, P<0.01 following injection of the V1-type vasopressin antagonist d(CH25-Tyr(Me-AVP into the SON. These results suggest that both AT1 and V1 receptors within the SON may be involved in water and sodium intake induced by the activation of ANG II receptors within the MSA. Furthermore, they do not support the involvement of MSA AT2 receptors in the mediation of these responses.

  5. Physiological and behavioural effects of intradermal injection of sodium lauryl sulfate as an alternative to mulesing in lambs.

    Science.gov (United States)

    Colditz, I G; Paull, D R; Lee, C; Fisher, A D

    2010-12-01

    To assess the effects on physiology and behaviour of intradermal injection of sodium lauryl sulfate (SLS) as an alternative to mulesing. Three groups of Merino lambs were studied: Control (n = 10), SLS (n = 11) and Mulesed (n = 11). The SLS group received SLS (7% w/v) and benzyl alcohol (20 mg/mL) in phosphate buffer, and the Mulesed group received 6 mL topical local anaesthetic as a wound dressing. Haematology, cortisol, beta-endorphin and haptoglobin concentrations, rectal temperatures, body weight and behaviours were monitored for up to 42 days post treatments. SLS treatment induced mild swelling followed by thin scab formation. Fever (>40°C) was observed at 12 and 24 h, cortisol concentration was elevated on days 1 and 2, haptoglobin concentration was highly elevated on days 2-7, white blood cell count was elevated on days 2 and 4 post treatment, but average daily gain was not affected. Fever at 12 h was significantly higher in the SLS than in the Mulesed group, whereas maximum temperature, temperature area under the curve (AUC), occurrence of fever, cortisol profile, cortisol AUC, white blood cell counts and haptoglobin concentrations until day 7 were comparable. The behaviours of normal standing, total standing and total lying were modified for 2 days by SLS treatment, but changes were less marked and of shorter duration than in the Mulesed group. On day 1, the SLS group spent <5% of time in total abnormal behaviours compared with 18% in the Mulesed group. The SLS group tended to spend more time in abnormal behaviours on day 1 than the Controls. The behaviour of the SLS group was similar to that of the unmulesed Controls and their physiological responses were intermediate between the Mulesed lambs receiving post-surgical analgesia and the Controls. © 2010 CSIRO. Australian Veterinary Journal © 2010 Australian Veterinary Association.

  6. Flow injection determination of diclofenac sodium based on its sensitizing effect on the chemiluminescent reaction of acidic potassium permanganate-formaldehyde.

    Science.gov (United States)

    Song, Jingjing; Sun, Pulv; Ji, Zhongling; Li, Jianguo

    2015-02-01

    A sensitive and simple chemiluminescent (CL) method for the determination of diclofenac sodium has been developed by combining the flow injection technique and its sensitizing effect on the weak CL reaction between formaldehyde and acidic potassium permanganate. A calibration curve is constructed for diclofenac sodium under optimized experimental parameters over the range 0.040-5.0 µg/mL and the limit of detection is 0.020 µg/mL (3σ). The inter-assay relative standard deviation for 0.040 µg/mL diclofenac sodium (n = 11) is 2.0%. This method is rapid, sensitive, simple, and shows good selectivity and reproducibility. The proposed method has been successfully applied to the determination of the studied diclofenac sodium in pharmaceutical preparations with satisfactory results. Furthermore, the possible mechanism for the CL reaction has been discussed in detail on the basis of UV and CL spectra. Copyright © 2014 John Wiley & Sons, Ltd.

  7. Efficacy and safety of single injection of cross-linked sodium hyaluronate vs. three injections of high molecular weight sodium hyaluronate for osteoarthritis of the knee: a double-blind, randomized, multi-center, non-inferiority study.

    Science.gov (United States)

    Ha, Chul-Won; Park, Yong-Beom; Choi, Chong-Hyuk; Kyung, Hee-Soo; Lee, Ju-Hong; Yoo, Jae Doo; Yoo, Ju-Hyung; Choi, Choong-Hyeok; Kim, Chang-Wan; Kim, Hee-Chun; Oh, Kwang-Jun; Bin, Seong-Il; Lee, Myung Chul

    2017-05-26

    This randomized, double-blind, multi-center, non-inferiority trial was conducted to assess the efficacy and safety of a cross-linked hyaluronate (XLHA, single injection form) compared with a linear high molecular hyaluronate (HMWHA, thrice injection form) in patients with symptomatic knee osteoarthritis. Two hundred eighty seven patients with osteoarthritis (Kellgren-Lawrence grade I to III) were randomized to each group. Three weekly injections were given in both groups but two times of saline injections preceded XLHA injection to maintain double-blindness. Primary endpoint was the change of weight-bearing pain (WBP) at 12 weeks after the last injection. Secondary endpoints included Western Ontario and McMaster Universities Osteoarthritis index; patient's and investigator's global assessment; pain at rest, at night, or in motion; OMERACT-OARSI responder rate; proportion of patients achieving at least 20 mm or 40% decrease in WBP; and rate of rescue medicine use and its total consumption. Mean changes of WBP at 12 weeks after the last injection were -33.3 mm with XLHA and -29.2 mm with HMWHA, proving non-inferiority of XLHA to HMWHA as the lower bound of 95% CI (-1.9 mm, 10.1 mm) was well above the predefined margin (-10 mm). There were no significant between-group differences in all secondary endpoints. Injection site pain was the most common adverse event and no remarkable safety issue was identified. This study demonstrated that a single injection of XLHA was non-inferior to three weekly injections of HMWHA in terms of WBP reduction, and supports XLHA as an effective and safe treatment for knee osteoarthritis. ClinicalTrials.gov ( NCT01510535 ). This trial was registered on January 6, 2012.

  8. A study on sodium-concrete reaction

    Energy Technology Data Exchange (ETDEWEB)

    Bae, Jae Heum; Min, Byong Hun [Suwon University, Suwon (Korea, Republic of)

    1997-07-01

    A small sodium-concrete reaction facility was designed, manufactured and installed. this facility has been operated under inert gas(N{sub 2}) with different experimental variables such as sodium injection temperature, injection amount of sodium, aging period of concrete, sodium reservoir temperature. As a result, it was found that sodium injection temperature and injected amount of sodium has little effect on sodium-concrete reaction. However, sodium reservoir temperature and aging period of concrete has relatively high impact on sodium-concrete reaction. Sodium-concrete reaction model has also been developed and compared with experimental results. (Author) 51 refs., 16 tabs., 64 figs.

  9. Ultrasound-guided subacromial injections of sodium hyaluronate for the management of rotator cuff tendinopathy: a prospective comparative study with rehabilitation therapy.

    Science.gov (United States)

    Merolla, G; Bianchi, P; Porcellini, G

    2013-06-01

    Rotator cuff (RC) tendinopathy is a common cause of pain and shoulder dysfunction. The literature evidence suggests that a combination of overuse and extrinsic compression may induce chronic RC tendinopathy. Aim of the current study was to compare the results of subacromial sodium hyaluronate injections with rehabilitation therapy. We enrolled 48 patients (M/F: 26/22; mean age: 50 years; shoulder right/left: 29/19) with persistent shoulder pain for at least 4 months. Exclusion criteria were as follows: RC tear, calcifying tendinitis, glenohumeral instability, osteoarthritis, rheumatic diseases, physical therapy and/or injection in the previous 4 months, shoulder surgery, anesthetic nerve block, trauma, and severe medical diseases. The included subjects received either two ultrasound-guided subacromial hyaluronic acid (HA) injections (25 patients, HA group) at baseline and 14 days, or underwent rehabilitation therapy (23 patients, Physio group) including active shoulder mobilization, soft tissue stretching and humeral head positioner and propeller muscles strengthening for 30 days (3 sessions every week). Clinical assessment of shoulder function was performed with visual analog scale score for pain (0-100), Oxford Shoulder Score (OSS), and Constant-Murley Score (CS). Overall, patients were examined at baseline, week 2, week 4, week 12, and week 24. Statistical significance was set at 5 % (p  0.05), week 12 (p > 0.05), and week 24 (p > 0.05). CS and OSS in the HA group increased significantly at week 2 (p  0.05). A significant improvement of CS and OSS we found in the Physio group at week 2 (p  0.05). Subacromial HA injections could be an effective and safe alternative treatment for patients suffering from RC tendinopathy. We believe that the results of this study are encouraging but not lasting and we might suppose that a series of three to four subacromial sodium hyaluronate injections could provide good mid- and long-term clinical benefits.

  10. Effect of pegaptanib sodium 0.3 mg intravitreal injections (Macugen) in intraocular pressure: posthoc analysis from VISION study

    NARCIS (Netherlands)

    Boyer, David S.; Goldbaum, Mauro; Leys, Anita M.; Starita, Carla; Blumenkranz, M.; Buyse, M.; Goldberg, M.; Gragoudas, E. S.; Miller, J.; Schwartz, S. D.; Singerman, L.; Yannuzzi, L.; Adamis, A. P.; Guyer, D. R.; O'Shaughnessy, D.; de Gronckel, S.; Fesneau, G.; Quinaux, E.; Tremolet, D.; Wang, K.; Brailey, A.; Finman, J.; Ting, N.; Bressler, N. M.; Bressler, S. B.; Denblow, R.; Schein, O. D.; Seabrook, S.; Solomon, S.; Schachat, A. P.; Philips, D.; Altaweel, M.; Davis, M. D.; Blodi, Ba; Danis, R. P.; Ip, M. S.; Hiner, C.; Elledge, J.; Webster, M.; Hannan, C.; Ficken, J.; Alexander, S.; Neider, M.; Wabers, H.; Vargo, P.; Lambert, E.; Kastorff, L.; Carr, A.; Shkiele, A.; Schlingemann, R. O.

    2014-01-01

    Objective To assess the rate of pegaptanib-associated sustained intraocular pressure (IOP) elevation. Methods A posthoc analysis was conducted on all IOP measurements, except the immediate 30-min postinjection, from all subjects randomised to pegaptanib 0.3 mg or sham injections continuously in the

  11. Integrated dry NO{sub x}/SO{sub 2} emissions control system sodium-based dry sorbent injection test report. Test period: August 4, 1993--July 29, 1995

    Energy Technology Data Exchange (ETDEWEB)

    Smith, R.A.; Shimoto, G.H.; Muzio, L.J. [Fossil Energy Research Corp., Laguna Hills, CA (United States); Hunt, T. [Public Service Co. of Colorado, Denver, CO (United States)

    1997-04-01

    The project goal is to demonstrate up to 70% reductions in NOx and SO{sub 2} emissions through the integration of: (1) down-fired low-NOx burners with overfire air; (2) Selective Non-Catalytic Reduction (SNCR) for additional NOx removal; and (3) dry sorbent injection and duct humidification for SO{sub 2} removal. This report documents the sixth phase of the test program, where the performance of dry sorbent injection with sodium compounds was evaluated as a SO{sub 2} removal technique. Dry sorbent injection was performed in-duct downstream of the air heater (ahead of the fabric filter), as well as at a higher temperature location between the economizer and air heater. Two sodium compounds were evaluated during this phase of testing: sodium sesquicarbonate and sodium bicarbonate. In-duct sodium injection with low levels of humidification was also investigated. This sixth test phase was primarily focused on a parametric investigation of sorbent type and feed rate, although boiler load and sorbent preparation parameters were also varied.

  12. Development and Validation of a Rapid Turbidimetric Assay to Determine the Potency of Cefuroxime Sodium in Powder for Dissolution for Injection

    Directory of Open Access Journals (Sweden)

    Daniela C. M. Vieira

    2014-07-01

    Full Text Available The cefuroxime sodium is a second generation cephalosporin indicated for infections caused by Gram-positive and Gram-negative microorganisms. Although this drug is highly studied and researched regarding the antimicrobial activity, pharmacokinetics and pharmacodynamics, there are few studies regarding the development of analytical methodology for this cephalosporin. Thus, research involving analytical methods is essential and highly relevant to optimize its analysis in the pharmaceutical industry and guarantee the quality of the product already sold. This study describes the development and validation of a microbiological assay applying the turbidimetric method for the determination of cefuroxime, using Micrococcus luteus ATCC 9341 as micro-organism test and 3x3 parallel line assay design, with nine tubes for each assay, as recommended by the Brazilian Pharmacopoeia. The developed and validated method showed excellent results of linearity, seletivity, precision and robustness, in the concentration range from 30.0 to 120.0 mg/mL, with 100.21% accuracy and content 99.97% to cefuroxime sodium in injectable pharmaceutical form.

  13. Influence of injected caffeine on the metabolism of calcium and the retention and excretion of sodium, potassium, phosphorus, magnesium, zinc and copper in rats.

    Science.gov (United States)

    Yeh, J K; Aloia, J F; Semla, H M; Chen, S Y

    1986-02-01

    Mineral metabolism was studied by the metabolic balance technique in rats with and without administration of caffeine. Caffeine was injected subcutaneously each day at either 2.5 mg or 10 mg/100 g body weight for 2 wk before the balance studies. Urinary volume excretion was higher in the group given caffeine than in the control group, but the creatinine clearance was not different. Urinary excretion of potassium, sodium, inorganic phosphate, magnesium and calcium, but not of zinc and copper, was also higher in the rats given caffeine. The rank order of the difference was the same as the percent of ingested mineral excreted in urine in the absence of caffeine. Caffeine caused a negative balance of potassium, sodium and inorganic phosphate. There was no significant difference from the control levels and in the apparent metabolic balance of calcium and magnesium. The urinary and fecal excretion of zinc and copper were found to be unaffected by caffeine. It is suggested that chronic administration of caffeine may lead to a tendency toward deficiency of those minerals that are excreted primarily in urine.

  14. Prognostic indicators of the outcome of arthrocentesis with and without sodium hyaluronate injection for the treatment of disc displacement without reduction: a magnetic resonance imaging study.

    Science.gov (United States)

    Aktas, I; Yalcin, S; Sencer, S

    2010-11-01

    This study analysed the prognostic factors for successful arthrocentesis with and without sodium hyaluronate (SH) injection for the treatment of temporomandibular joint (TMJ) disc displacement without reduction (DDwoR) using clinical and radiological results. 29 TMJs in 25 patients with DDwoR were included. Patients were treated with arthrocentesis or arthrocentesis followed by intra-articular (i.a.) injection of SH. Treatment was evaluated for postoperative range of maximum mouth opening and the degree of postoperative pain on a VAS. Prognostic factors analysed were age, sex, duration of locking, trauma history, previous TMJ treatment, depression, bruxism, malocclusion and missing teeth. Degenerative changes were evaluated as probable prognostic factors. After treatment, 24 joints (83%) fulfilled the criteria for success. Duration of locking and present preoperative degenerative changes were the most significant factors for treatment outcome. The results suggest it is sufficient to use only arthrocentesis in patients without preoperative degenerative changes and arthrocentesis with SH in patients with degenerative changes on their preoperative MRIs, but because there were some significant differences between the two groups preventing the authors from comparing them statistically, they cannot come to that conclusion. To clarify the use of SH in such cases, standardized study groups are necessary for future studies. Crown Copyright © 2010. Published by Elsevier Ltd. All rights reserved.

  15. Long-term clinical benefit and cost-effectiveness of an 8-week multimodal knee osteoarthritis management program incorporating intra-articular sodium hyaluronate (Hyalgan® injections

    Directory of Open Access Journals (Sweden)

    Miller LE

    2017-05-01

    Full Text Available Larry E Miller,1 Michael J Sloniewsky,2 Thomas E Gibbons,3 Janice G Johnston,4 Kent D Vosler,4 Saad Nasir5 1Miller Scientific Consulting, Inc., Asheville, NC, 2RMG Holding, Inc., Florence, 3Doctors Care, PA, Columbia, SC, 4Arrowhead Health Centers, Glendale, AZ, 5Fidia Pharma USA Inc., Parsippany, NJ, USA Background: Given the poor long-term effectiveness of focused nonsurgical knee osteoarthritis (OA treatments, alternative therapies are needed for patients who have unsuccessfully exhausted nonsurgical options.Methods: A telephone interview was conducted in patients who participated in a single 8-week multimodal knee OA treatment program (mean follow-up: 3.7 years, range: 2.7–4.9 years. The program consisted of five intra-articular knee injections of sodium hyaluronate (Hyalgan®, with each injection given 1 week apart, structured physical therapy, knee bracing, and patient education. Clinical outcomes included knee pain severity, Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC subscores, current medication use, and history of total knee arthroplasty. Base-case, subgroup, and sensitivity analyses were conducted to determine the incremental cost-effectiveness ratio (ICER of the treatment program with comparisons made to historical literature controls undergoing usual care. Results: A total of 218 patients (54% provided long-term follow-up data. Knee pain severity decreased 60% and WOMAC subscores decreased 33%–42% compared to baseline (all p<0.001. Total knee arthroplasty was performed in 22.8% (81/356 of knees during follow-up. The treatment program was highly cost-effective compared to usual care with a base-case ICER of $6,000 per quality-adjusted life year (QALY. Results of subgroup analyses, one-way deterministic sensitivity analyses, and second-order probabilistic sensitivity analyses resulted in ICERs ranging from $3,996 to $10,493 per QALY. The percentage of simulations with an ICER below willingness

  16. Compatibility and stability of morphine sulphate and naloxone hydrochloride in 0.9% sodium chloride for injection.

    Science.gov (United States)

    Kistner, Charlotte; Ensom, Mary H H; Decarie, Diane; Lauder, Gillian; Carr, Roxane R

    2013-05-01

    Naloxone may be administered in conjunction with morphine to reduce the risk of opioid-induced pruritis. Combining these drugs for coadministration may be beneficial, but little is known about their physical compatibility and stability in combined solutions. To describe the physical compatibility and stability of morphine sulphate and naloxone hydrochloride (at various concentrations) in IV admixtures. The physical compatibility and stability of admixtures of morphine 1000 μg/mL and naloxone 4 μg/mL, 12.5 μg/mL, and 25 μg/mL in 0.9% sodium chloride were studied. For each concentration of naloxone, one bag was stored at room temperature (22°C) for 72 h and one bag was stored under refrigeration (4°C) for 30 days. For all preparations, physical characteristics, including pH, colour, and formation of precipitate, were evaluated. The samples were also analyzed by a stability-indicating high-performance liquid chromatographic method. Stability was defined as the retention of at least 90% of the initial concentration. No notable changes in pH or colour and no macroprecipitation were observed in any of the preparations after storage at 22°C for up to 72 h or at 4°C for up to 30 days. All preparations maintained more than 90% of the initial concentrations of morphine and naloxone at the end of the respective study periods. The calculated lower limit of the 95% confidence interval also indicated that 90% or more of the initial concentration remained at the end of each study period. Admixtures of morphine sulphate and naloxone hydrochloride were stable for 72 h at room temperature and for 30 days with refrigeration.

  17. Accurate, safe, and rapid method of intraoperative tumor identification for totally laparoscopic distal gastrectomy: injection of mixed fluid of sodium hyaluronate and patent blue.

    Science.gov (United States)

    Nakagawa, Masatoshi; Ehara, Kazuhisa; Ueno, Masaki; Tanaka, Tsuyoshi; Kaida, Sachiko; Udagawa, Harushi

    2014-04-01

    In totally laparoscopic distal gastrectomy, determining the resection line with safe proximal margins is often difficult, particularly for tumors located in a relatively upper area. This is because, in contrast to open surgery, identifying lesions by palpating or opening the stomach is essentially impossible. This study introduces a useful method of tumor identification that is accurate, safe, and rapid. On the operation day, after inducing general anesthesia, a mixture of sodium hyaluronate and patent blue is injected into the submucosal layer of the proximal margin. When resecting stomach, all marker spots should be on the resected side. In all cases, the proximal margin is examined histologically by using frozen sections during the operation. From October 2009 to September 2011, a prospective study that evaluated this method was performed. A total of 34 patients who underwent totally laparoscopic distal gastrectomy were enrolled in this study. Approximately 5 min was required to complete the procedure. Proximal margins were negative in all cases, and the mean ± standard deviation length of the proximal margin was 23.5 ± 12.8 mm. No side effects, such as allergy, were encountered. As a method of tumor identification for totally laparoscopic distal gastrectomy, this procedure appears accurate, safe, and rapid.

  18. Compatibility of pantoprazole sodium for injection combined with eight common injections%注射用泮托拉唑钠与8种常用注射剂的配伍稳定性考察

    Institute of Scientific and Technical Information of China (English)

    许锦英; 孙华; 梁大虎; 殷勤; 盛雪鹤; 刘孟雪; 姚瑶; 周露露; 黄越

    2017-01-01

    OBJECTIVE To investigate the compatibility of pantoprazole combined with eight commonly administered injectables under ambient room temperature.METHODS The HPLC method for pantoprazole determination was established.Simulated Y-site compatibility evaluation was accomplished by mixing pantoprazole with an alternative intravenous medication (inosine injection,vitamin B6 injection,vitamin K1 injection,coenzyme A for injection,aminomethylbenzoic acid injection,ethamsylate injection,potassium magnesium aspartate injection and adenosine disodium triphosphate injection) in NS,and then the mixture was stored in a polypropylene syringe for 2 h.The concentration of pantoprazole,appearance,the number of insoluble particles and pH value of pantoprazole in admixtures were observed immediately and at 0.5,1 and 2 h.RESULTS The content of pantoprazole declined obviously in two hours after mixing with aminomethylbenzoic acid injection,etamsylate and vitamin B6 injection,respectively.CONCLUSION The pantoprazole injection is sensitive to pH value,and should not be administered concomitantly with aminomethylbenzoic acid injection,etamsylate or vitamin 6 injection.Furthermore,the pipeline should be cleaned when pantoprazole is sequential Y-site administered with any one of these products.%目的:考察室温条件下注射用泮托唑钠与8种临床常用药物的配伍稳定性.方法:建立了泮托拉唑钠高效液相含量测定方法,模拟临床应用,以0.9%的氯化钠溶液为溶媒,按比例分别将注射用泮托拉唑钠与肌苷注射液、维生素&注射液、维生素K1注射液、注射用辅酶A、氨苯甲酸注射液、酚磺乙胺注射液、门冬氨酸钾镁注射液、注射用ATP 8种临床常见药物混合,在混合后即刻、0.5,1,2h4个时间点考察泮托拉唑含量、外观、不溶性微粒、溶液pH值的变化.结果:泮托拉唑钠与氨苯甲酸、酚磺乙胺、维生素B6配伍后2h内含量明显下降.结论:泮托拉唑对pH敏感,注

  19. Angiotensin II's role in sodium lactate-induced panic-like responses in rats with repeated urocortin 1 injections into the basolateral amygdala

    DEFF Research Database (Denmark)

    Johnson, Philip L; Sajdyk, Tammy J; Fitz, Stephanie D

    2013-01-01

    Rats treated with three daily urocortin 1 (UCN) injections into the basolateral amygdala (BLA; i.e., UCN/BLA-primed rats) develop prolonged anxiety-associated behavior and vulnerability to panic-like physiological responses (i.e., tachycardia, hypertension and tachypnea) following intravenous...

  20. Intravitreal flomoxef sodium in rabbits.

    Science.gov (United States)

    Mochizuki, K; Torisaki, M; Yamashita, Y; Komatsu, M; Tanahashi, T

    1993-01-01

    We studied the intraocular concentration of flomoxef sodium in nonvitrectomized and vitrectomized eyes of albino rabbits after intravenous administration of 100 mg/kg flomoxef sodium. The concentration of flomoxef sodium in the vitreous body was undetectable (flomoxef sodium was investigated with ophthalmoscopy, electroretinography (ERG) and light microscopy after intravitreal injection of 200, 500, 1,000 and 2,000 micrograms flomoxef sodium in albino and pigmented rabbits. No ERG changes were induced with 200 micrograms. Other higher doses caused transient ERG changes. After the 200-micrograms injection, the intravitreal concentration decreased exponentially, the half-life being 4.4 h. The antibacterial activity, broad coverage and low intravitreal toxicity of flomoxef sodium suggest that this compound may be used to treat bacterial endophthalmitis.

  1. Comparative Evaluation of U.S. Brand and Generic Intravenous Sodium Ferric Gluconate Complex in Sucrose Injection: In Vitro Cellular Uptake

    Directory of Open Access Journals (Sweden)

    Min Wu

    2017-12-01

    Full Text Available Iron deficiency anemia is a common clinical consequence for people who suffer from chronic kidney disease, especially those requiring dialysis. Intravenous (IV iron therapy is a widely accepted safe and efficacious treatment for iron deficiency anemia. Numerous IV iron drugs have been approved by U.S. Food and Drug Administration (FDA, including a single generic product, sodium ferric gluconate complex in sucrose. In this study, we compared the cellular iron uptake profiles of the brand (Ferrlecit® and generic sodium ferric gluconate (SFG products. We used a colorimetric assay to examine the amount of iron uptake by three human macrophage cell lines. This is the first published study to provide a parallel evaluation of the cellular uptake of a brand and a generic IV iron drug in a mononuclear phagocyte system. The results showed no difference in iron uptake across all cell lines, tested doses, and time points. The matching iron uptake profiles of Ferrlecit® and its generic product support the FDA’s present position detailed in the draft guidance on development of SFG complex products that bioequivalence can be based on qualitative (Q1 and quantitative (Q2 formulation sameness, similar physiochemical characterization, and pharmacokinetic bioequivalence studies.

  2. Determination of inorganic mercury and total mercury in biological and environmental samples by flow injection-cold vapor-atomic absorption spectrometry using sodium borohydride as the sole reducing agent

    International Nuclear Information System (INIS)

    Rio Segade, Susana; Tyson, Julian F.

    2003-01-01

    A simple, fast, precise and accurate method to determine inorganic mercury and total mercury in biological and environmental samples was developed. The optimized flow-injection mercury system permitted the separate determination of inorganic mercury and total mercury using sodium borohydride as reducing agent. Inorganic mercury was selectively determined after reduction with 10 -4 % w/v sodium borohydride, while total mercury was determined after reduction with 0.75% w/v sodium borohydride. The calibration graphs were linear up to 30 ng ml -1 . The detection limits of the method based on three times the standard deviation of the blank were 24 and 3.9 ng l -1 for total mercury and inorganic mercury determination, respectively. The relative standard deviation was less than 1.5% for a 10 ng ml -1 mercury standard. As a means of checking method performance, deionized water and pond water samples were spiked with methylmercury and inorganic mercury; quantitative recovery for total mercury and inorganic mercury was obtained. The accuracy of the method was verified by analyzing alkaline and acid extracts of five biological and sediment reference materials. Microwave-assisted extraction procedures resulted in higher concentrations of recovered mercury species, lower matrix interference with mercury determination and less time involved in sample treatment than conventional extraction procedures. The standard addition method was only needed for calibration when biological samples were analyzed. The detection limits were in the range of 1.2-19 and 6.6-18 ng g -1 in biological and sediment samples for inorganic mercury and total mercury determination, respectively

  3. Sodium cooled fast reactor

    Energy Technology Data Exchange (ETDEWEB)

    Hokkyo, N; Inoue, K; Maeda, H

    1968-11-21

    In a sodium cooled fast neutron reactor, an ultrasonic generator is installed at a fuel assembly hold-down mechanism positioned above a blanket or fission gas reservoir located above the core. During operation of the reactor an ultrsonic wave of frequency 10/sup 3/ - 10/sup 4/ Hz is constantly transmitted to the core to resonantly inject the primary bubble with ultrasonic energy to thereby facilitate its growth. Hence, small bubbles grow gradually to prevent the sudden boiling of sodium if an accident occurs in the cooling system during operation of the reactor.

  4. Low sodium diet (image)

    Science.gov (United States)

    ... for you. Look for these words on labels: low-sodium, sodium-free, no salt added, sodium-reduced, ... for you. Look for these words on labels: low-sodium, sodium-free, no salt added, sodium-reduced, ...

  5. Characterization of Sodium Spray Aerosols

    Energy Technology Data Exchange (ETDEWEB)

    Nelson, C. T.; Koontz, R. L.; Silberberg, M. [Atomics International, North American Rockwell Corporation, Canoga Park, CA (United States)

    1968-12-15

    The consequences of pool and spray fires require evaluation in the safety analysis of liquid metal-cooled fast breeder reactors. Sodium spray fires are characterized by high temperature and pressure, produced during the rapid combustion of sodium in air. Following the initial energy release, some fraction of the reaction products are available as aerosols which follow the normal laws of agglomeration, growth, settling, and plating. An experimental study is underway at Atomics International to study the characteristics of high concentration sprays of liquid sodium in reduced oxygen atmospheres and in air. The experiments are conducted in a 31.5 ft{sup 3} (2 ft diam. by 10 ft high) vessel, certified for a pressure of 100 lb/in{sup 2} (gauge). The spray injection apparatus consists of a heated sodium supply pot and a spray nozzle through which liquid sodium is driven by nitrogen pressure. Spray rate and droplet size can be varied by the injection velocity (nozzle size, nitrogen pressure, and sodium temperature). Aerosols produced in 0, 4, and 10 vol. % oxygen environments have been studied. The concentration and particle size distribution of the material remaining in the air after the spray injection and reaction period are measured. Fallout rates are found to be proportional to the concentration of aerosol which remains airborne following the spray period. (author)

  6. Hidden Sodium

    Centers for Disease Control (CDC) Podcasts

    2013-03-04

    In this podcast, learn about reducing sodium intake by knowing what to eat and the main sources of sodium in the diet. It's important for a healthy lifestyle.  Created: 3/4/2013 by National Center for Chronic Disease Prevention and Health Promotion (NCCDPHP).   Date Released: 3/4/2013.

  7. Dietary sodium

    DEFF Research Database (Denmark)

    Graudal, Niels

    2015-01-01

    The 2013 Institute of Medicine (IOM) report "Sodium Intake in Populations: Assessment of Evidence" did not support the current recommendations of the IOM and the American Heart Association (AHA) to reduce daily dietary sodium intake to below 2,300 mg. The report concluded that the population...

  8. Water Mock-up for the Sodium Waste Treatment Process

    Energy Technology Data Exchange (ETDEWEB)

    Nam, Ho Yun; Kim, Jong Man; Kim, Byung Ho; Lee, Yong Bum [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2011-05-15

    It is important to safely treat the waste sodium which was produced from the sodium cooled fast reactors and the sodium facilities. About 1.3 tons of sodium waste has accumulated at KAERI from the sodium experiments which have been carried out since 1990. Also, large scaled sodium experiments are scheduled to verify the design of the sodium cooled fast reactor. As a treatment method for the waste sodium produced at the sodium facility, an investigation of the reaction procedure of the waste sodium with the sodium hydroxide aqueous has been developed. The NOAH process was developed in France for the treatment of waste sodium produced from sodium facilities and reactors. In the NOAH process, a small amount of sodium waste is continuously injected into the upper space which is formed on the free surface of the aqueous and slowly reacted with sodium hydroxide aqueous. Since the density of the sodium is lower than that of the aqueous, the injected sodium waste sometimes accumulates above the free surface of the sodium hydroxide aqueous, and its reaction rate becomes slow or suddenly increases. In the improved process, the sodium was injected into a reaction vessel filled with a sodium hydroxide aqueous through an atomizing nozzle installed on a lower level than that of the aqueous to maintain the reaction uniformly. Fig.1 shows the sodium waste process which was proposed in KAERI. The aqueous is composed of 60% sodium hydroxide, and its temperature is about 60 .deg. C. The process is an exothermic reaction. The hydrogen gas is generated, and the concentration of the sodium hydroxide increases in this process. It needs several systems for the process, i.e. a waste sodium injection, a cooling of the aqueous, hydrogen ventilation, and neutralization with nitric acid. The atomizing nozzle was designed to inject the sodium with the nitrogen gas which supplies a heat to the sodium to prevent its solidification and to uniformly mix the sodium with the aqueous. There are

  9. Sodium: How to Tame Your Salt Habit

    Science.gov (United States)

    ... dogs, sausage and ham. Buy fresh or frozen poultry or meat that hasn't been injected with ... use of sodium-laden condiments. Soy sauce, salad dressings, sauces, dips, ketchup, mustard and relish all contain ...

  10. Testosterone Injection

    Science.gov (United States)

    ... typical male characteristics. Testosterone injection works by supplying synthetic testosterone to replace the testosterone that is normally ... as a pellet to be injected under the skin.Testosterone injection may control your symptoms but will ...

  11. Sodium Oxybate

    Science.gov (United States)

    ... or give your sodium oxybate to anyone else; selling or sharing it is against the law. Store ... dehydrogenase deficiency (an inherited condition in which certain substances build up in the body and cause retardation ...

  12. Sodium Azide

    Science.gov (United States)

    ... Exposure to a large amount of sodium azide by any route may cause these other health effects as well: Convulsions Low blood pressure Loss of consciousness Lung injury Respiratory failure leading to death Slow heart rate ...

  13. Analytical study of sodium combustion phenomena under sodium leak accidents

    International Nuclear Information System (INIS)

    Kim, Byung Ho; Jeong, J. Y.; Jeong, K. C.; Kim, T. J.; Choi, J. H.

    2001-12-01

    The rise of temperature and pressure, the release of aerosol in the buildings as a result of sodium fire must be considered for the safety measures of LMR. Therefore for the safety of the LMR, it is necessary to understand the characteristics of sodium fire, resulting from the various type of leakage. ASSCOPS(Analysis of Simultaneous Sodium Combustion in Pool and Spray) is the computer code for the analysis of the thermal consequence of sodium leak and fire in LMR that has been developed by Japan Nuclear Cycle Development Institute(JNC) in Japan. In this study, a preliminary analysis of sodium leak and fire accidents in S/G building of KALIMER is made by using ASSCOPS code. Various phenomena of interest are spray and pool burning, peak pressure, temperature change, local structure temperature, aerosol behavior, drain system into smothering tank, ventilation characteristics at each cell with the safety venting system and nitrogen injection system. In this calculation, the dimension of the S/G building was chosen in accordance with the selected options of LMR name KALIMER(Korea). As a result of this study, it was shown that subsequent effect of sodium fire depended upon whether the sodium continued to leak from the pipe or not, whether the ventilation system was running, whether the inert gas injection system was provided, whether the sodium on floor was drained into the smothering tank or not, whether the building was sealed or not, etc. Specially the excessive rise of pressure into each cell was prevented by installing the pressure release plates on wall of the building

  14. Sodium hypochlorite-induced acute kidney injury

    Directory of Open Access Journals (Sweden)

    Brandon W Peck

    2014-01-01

    Full Text Available Sodium hypochlorite (bleach is commonly used as an irrigant during dental proce-dures as well as a topical antiseptic agent. Although it is generally safe when applied topically, reports of accidental injection of sodium hypochlorite into tissue have been reported. Local necrosis, pain and nerve damage have been described as a result of exposure, but sodium hypo-chlorite has never been implicated as a cause of an acute kidney injury (AKI. In this report, we describe the first case of accidental sodium hypochlorite injection into the infraorbital tissue during a dental procedure that precipitated the AKI. We speculate that oxidative species induced by sodium hypochlorite caused AKI secondary to the renal tubular injury, causing mild acute tubular necrosis.

  15. Granisetron Injection

    Science.gov (United States)

    Granisetron immediate-release injection is used to prevent nausea and vomiting caused by cancer chemotherapy and to ... nausea and vomiting that may occur after surgery. Granisetron extended-release (long-acting) injection is used with ...

  16. Edaravone Injection

    Science.gov (United States)

    Edaravone injection is used to treat amyotrophic lateral sclerosis (ALS, Lou Gehrig's disease; a condition in which ... die, causing the muscles to shrink and weaken). Edaravone injection is in a class of medications called ...

  17. Meropenem Injection

    Science.gov (United States)

    ... injection is in a class of medications called antibiotics. It works by killing bacteria that cause infection.Antibiotics such as meropenem injection will not work for colds, flu, or other viral infections. Taking ...

  18. Chloramphenicol Injection

    Science.gov (United States)

    ... injection is in a class of medications called antibiotics. It works by stopping the growth of bacteria..Antibiotics such as chloramphenicol injection will not work for colds, flu, or other viral infections. Taking ...

  19. Colistimethate Injection

    Science.gov (United States)

    ... injection is in a class of medications called antibiotics. It works by killing bacteria.Antibiotics such as colistimethate injection will not work for colds, flu, or other viral infections. Using ...

  20. Defibrotide Injection

    Science.gov (United States)

    Defibrotide injection is used to treat adults and children with hepatic veno-occlusive disease (VOD; blocked blood ... the body and then returned to the body). Defibrotide injection is in a class of medications called ...

  1. Nalbuphine Injection

    Science.gov (United States)

    ... injection is in a class of medications called opioid agonist-antagonists. It works by changing the way ... suddenly stop using nalbuphine injection, you may experience withdrawal symptoms including restlessness; teary eyes; runny nose; yawning; ...

  2. Test Your Sodium Smarts

    Science.gov (United States)

    ... You may be surprised to learn how much sodium is in many foods. Sodium, including sodium chloride ... foods with little or no salt. Test your sodium smarts by answering these 10 questions about which ...

  3. Effectiveness of Chlorinated Water, Sodium Hypochlorite, Sodium ...

    African Journals Online (AJOL)

    This study evaluated the efficacy of chlorinated water, sodium hypochlorite solution, sodium chloride solution and sterile distilled water in eliminating pathogenic bacteria on the surfaces of raw vegetables. Lettuce vegetables were dipped in different concentrations of chlorinated water, sodium hypochlorite solution, sodium ...

  4. Subcutaneous Injections

    DEFF Research Database (Denmark)

    Thomsen, Maria

    This thesis is about visualization and characterization of the tissue-device interaction during subcutaneous injection. The tissue pressure build-up during subcutaneous injections was measured in humans. The insulin pen FlexTouchr (Novo Nordisk A/S) was used for the measurements and the pressure ...

  5. Hydromorphone Injection

    Science.gov (United States)

    ... anyone else to use your medication. Store hydromorphone injection in a safe place so that no one else can use it accidentally or on purpose. Keep track of how much medication is left so ... with hydromorphone injection may increase the risk that you will develop ...

  6. Ketorolac Injection

    Science.gov (United States)

    ... an older adult, you should know that ketorolac injection is not as safe as other medications that can be used to treat your condition. Your doctor may choose to prescribe a different medication ... to ketorolac injection.Your doctor or pharmacist will give you the ...

  7. Paclitaxel Injection

    Science.gov (United States)

    (pak'' li tax' el)Paclitaxel injection must be given in a hospital or medical facility under the supervision of a doctor who is experienced in giving chemotherapy medications for cancer.Paclitaxel injection may cause a large decrease in the number of white blood cells (a type of blood cell ...

  8. Sodium in diet

    Science.gov (United States)

    Diet - sodium (salt); Hyponatremia - sodium in diet; Hypernatremia - sodium in diet; Heart failure - sodium in diet ... Too much sodium in the diet may lead to: High blood pressure in some people A serious buildup of fluid in people with heart failure , cirrhosis of ...

  9. Fluconazole Injection

    Science.gov (United States)

    ... an irregular heartbeat; a low level of calcium, sodium, magnesium, or potassium in your blood; or heart, kidney, or liver disease.tell your doctor if you are pregnant, especially if you are in the first 3 months of your pregnancy, plan to become pregnant, or are breast-feeding. ...

  10. Temozolomide Injection

    Science.gov (United States)

    ... balance or coordination fainting dizziness hair loss insomnia memory problems pain, itching, swelling, or redness in the place where the medication was injected changes in vision Some side effects can be serious. If you ...

  11. Buprenorphine Injection

    Science.gov (United States)

    ... injection is in a class of medications called opiate partial agonists. It works to prevent withdrawal symptoms ... help. If the victim has collapsed, had a seizure, has trouble breathing, or can't be awakened, ...

  12. Risperidone Injection

    Science.gov (United States)

    ... release (long-acting) injection is used to treat schizophrenia (a mental illness that causes disturbed or unusual ... may help control your symptoms but will not cure your condition. Continue to keep appointments to receive ...

  13. Haloperidol Injection

    Science.gov (United States)

    ... haloperidol extended-release injection are used to treat schizophrenia (a mental illness that causes disturbed or unusual ... may help control your symptoms but will not cure your condition. Continue to keep appointments to receive ...

  14. Omalizumab Injection

    Science.gov (United States)

    ... injection is used to decrease the number of asthma attacks (sudden episodes of wheezing, shortness of breath, and ... about how to treat symptoms of a sudden asthma attack. If your asthma symptoms get worse or if ...

  15. Injection Tests

    CERN Document Server

    Kain, V

    2009-01-01

    The success of the start-up of the LHC on 10th of September was in part due to the preparation without beam and injection tests in 2008. The injection tests allowed debugging and improvement in appropriate portions to allow safe, efficient and state-of-the-art commissioning later on. The usefulness of such an approach for a successful start-up becomes obvious when looking at the problems we encountered before and during the injection tests and could solve during this period. The outline of the preparation and highlights of the different injection tests will be presented and the excellent performance of many tools discussed. A list of shortcomings will follow, leading to some planning for the preparation of the run in 2009.

  16. Cefotaxime Injection

    Science.gov (United States)

    ... is in a class of medications called cephalosporin antibiotics. It works by killing bacteria.Antibiotics such as cefotaxime injection will not work for colds, flu, or other viral infections. Using ...

  17. Cefuroxime Injection

    Science.gov (United States)

    ... is in a class of medications called cephalosporin antibiotics. It works by killing bacteria.Antibiotics such as cefuroxime injection will not work for colds, flu, or other viral infections. Using ...

  18. Doripenem Injection

    Science.gov (United States)

    ... is in a class of medications called carbapenem antibiotics. It works by killing bacteria.Antibiotics such as doripenem injection will not work for colds, flu, or other viral infections. Taking ...

  19. Daptomycin Injection

    Science.gov (United States)

    ... in a class of medications called cyclic lipopeptide antibiotics. It works by killing bacteria.Antibiotics such as daptomycin injection will not work for treating colds, flu, or other viral infections. ...

  20. Ceftaroline Injection

    Science.gov (United States)

    ... is in a class of medications called cephalosporin antibiotics. It works by killing bacteria.Antibiotics such as ceftaroline injection will not work for colds, flu, or other viral infections. Using ...

  1. Aztreonam Injection

    Science.gov (United States)

    ... is in a class of medications called carbapenem antibiotics. It works by killing bacteria.Antibiotics such as aztreonam injection will not work for colds, flu, or other viral infections. Taking ...

  2. Cefazolin Injection

    Science.gov (United States)

    ... is in a class of medications called cephalosporin antibiotics. It works by killing bacteria.Antibiotics such as cefazolin injection will not work for colds, flu, or other viral infections. Taking ...

  3. Ceftazidime Injection

    Science.gov (United States)

    ... is in a class of medications called cephalosporin antibiotics. It works by killing bacteria.Antibiotics such as ceftazidime injection will not work for colds, flu, or other viral infections. Using ...

  4. Cefotetan Injection

    Science.gov (United States)

    ... is in a class of medications called cephalosporin antibiotics. It works by killing bacteria.Antibiotics such as cefotetan injection will not work for colds, flu, or other viral infections. Using ...

  5. Cefoxitin Injection

    Science.gov (United States)

    ... is in a class of medications called cephamycin antibiotics. It works by killing bacteria.Antibiotics such as cefoxitin injection will not work for colds, flu, or other viral infections. Taking ...

  6. Tigecycline Injection

    Science.gov (United States)

    ... is in a class of medications called tetracycline antibiotics. It works by killing bacteria that cause infection.Antibiotics such as tigecycline injection will not work for colds, flu, or other viral infections. Using ...

  7. Ertapenem Injection

    Science.gov (United States)

    ... is in a class of medications called carbapenem antibiotics. It works by killing bacteria.Antibiotics such as ertapenem injection will not work for colds, flu, or other viral infections. Taking ...

  8. Ceftriaxone Injection

    Science.gov (United States)

    ... is in a class of medications called cephalosporin antibiotics. It works by killing bacteria.Antibiotics such as ceftriaxone injection will not work for colds, flu, or other viral infections.Using ...

  9. Cefepime Injection

    Science.gov (United States)

    ... is in a class of medications called cephalosporin antibiotics. It works by killing bacteria.Antibiotics such as cefepime injection will not work for colds, flu, or other viral infections. Using ...

  10. Telavancin Injection

    Science.gov (United States)

    ... is in a class of medications called lipoglycopeptide antibiotics. It works by killing bacteria that cause infection.Antibiotics such as telavancin injection will not work for colds, flu, or other viral infections. Using ...

  11. Doxycycline Injection

    Science.gov (United States)

    ... is in a class of medications called tetracycline antibiotics. It works by killing bacteria that cause infections.Antibiotics such as doxycycline injection will not work for colds, flu, or other viral infections. Taking ...

  12. Vancomycin Injection

    Science.gov (United States)

    ... is in a class of medications called glycopeptide antibiotics. It works by killing bacteria that cause infections.Antibiotics such as vancomycin injection will not work for colds, flu, or other viral infections. Taking ...

  13. Octreotide Injection

    Science.gov (United States)

    ... carton and protect it from light. Dispose of multi-dose vials of the immediate-release injection 14 ... and immediately place the medication in a safe location – one that is up and away and out ...

  14. Moxifloxacin Injection

    Science.gov (United States)

    ... tendon area, or inability to move or to bear weight on an affected area.Using moxifloxacin injection ... muscle weakness) and cause severe difficulty breathing or death. Tell your doctor if you have myasthenia gravis. ...

  15. Delafloxacin Injection

    Science.gov (United States)

    ... a tendon area, or inability to move or bear weight on an affected area.Using delafloxacin injection ... muscle weakness) and cause severe difficulty breathing or death. Tell your doctor if you have myasthenia gravis. ...

  16. Levofloxacin Injection

    Science.gov (United States)

    ... tendon area, or inability to move or to bear weight on an affected area.Using levofloxacin injection ... muscle weakness) and cause severe difficulty breathing or death. Tell your doctor if you have myasthenia gravis. ...

  17. Ciprofloxacin Injection

    Science.gov (United States)

    ... a tendon area, or inability to move or bear weight on an affected area.Using ciprofloxacin injection ... muscle weakness) and cause severe difficulty breathing or death. Tell your doctor if you have myasthenia gravis. ...

  18. Alirocumab Injection

    Science.gov (United States)

    ... 9 (PCSK9) inhibitor monoclonal antibodies. It works by blocking the production of LDL cholesterol in the body ... hives difficulty breathing or swallowing swelling of the face, throat, tongue, lips, and eyes Alirocumab injection may ...

  19. Evolocumab Injection

    Science.gov (United States)

    ... 9 (PCSK9) inhibitor monoclonal antibody. It works by blocking the production of LDL cholesterol in the body ... hives difficulty breathing or swallowing swelling of the face, throat, tongue, lips, and eyes Evolocumab injection may ...

  20. Acyclovir Injection

    Science.gov (United States)

    ... It is also used to treat first-time genital herpes outbreaks (a herpes virus infection that causes sores ... in the body. Acyclovir injection will not cure genital herpes and may not stop the spread of genital ...

  1. Butorphanol Injection

    Science.gov (United States)

    ... Butorphanol is in a class of medications called opioid agonist-antagonists. It works by changing the way ... suddenly stop using butorphanol injection, you may experience withdrawal symptoms such as nervousness, agitation, shakiness, diarrhea, chills, ...

  2. Sodium technology handbook

    International Nuclear Information System (INIS)

    2005-09-01

    This document was published as a textbook for the education and training of personnel working for operations and maintenances of sodium facilities including FBR plants and those engaged in R and D activities related to sodium technology. This handbook covers the following technical areas. Properties of sodium. Compatibilities of sodium with materials. Thermalhydraulics and structural integrity. Sodium systems and components. Sodium instrumentations. Sodium handling technology. Sodium related accident evaluation and countermeasures for FBRs. Operation, maintenance and repair technology of sodium facilities. Safety measures related to sodium. Laws, regulations and internal rules related to sodium. The plannings and discussions of the handbook were made in the Sodium Technology Education Committee organized in O-arai Engineering Center consisting of the representatives of the related departments including Tsuruga headquarters. Experts in various departments participated in writing individual technical subjects. (author)

  3. Acoustic detection for small-leak sodium-water reaction

    International Nuclear Information System (INIS)

    Nei, Hiromichi; Ohshima, Iwao; Ujihara, Kozaburo; Hori, Masao

    1977-01-01

    Characteristics of acoustic signal produced by sodium-water reaction due to steam injection and by Ar gas injection into sodium were experimentally investigated. Acoustic signal was measured by using Kistler 808A and 815A5 accelerometers. Root mean square (RMS) measurements and frequency analysis of the signal were conducted. The RMS measurements could detect a small water leakage into sodium, as small as 0.07g/sec, in the present loop. The peaks in a frequency spectrum were caused by the natural vibration of a rod on which the acoustic transducer was mounted. The RMS was approximately proportional to the one-third power of the steam leak rate and increased to some extent with the ambient sodium temperature. RMS values, both for sodium-water reaction and Ar gas injection, were about the same order of magnitude, when the data were plotted against the volumetric flow rates of steam and Argas. (auth.)

  4. The sodium coolant

    International Nuclear Information System (INIS)

    Rodriguez, G.

    2004-01-01

    The sodium is the best appropriate coolant for the fast neutrons reactors technology. Thus the fast neutrons reactors development is intimately bound to the sodium technology. This document presents the sodium as a coolant point of view: atomic structure and characteristics, sodium impacts on the fast neutron reactors technology, chemical properties of the sodium and the consequences, quality control in a nuclear reactor, sodium treatment. (A.L.B.)

  5. Preliminary Plugging tests in Narrow Sodium Channels by Sodium and Carbon Dioxide reaction

    Energy Technology Data Exchange (ETDEWEB)

    Park, Sun Hee; Wi, Myung-Hwan; Min, Jae Hong [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-05-15

    This report is on the investigation of the physical/chemical phenomena that a slow loss of CO{sub 2} inventory into sodium after the sodium-CO{sub 2} boundary failure in PCHEs in realistic operating conditions. The first phenomenon is potential channel plugging inside the narrow PCHE channel. Unlike a conventional shell and- tube type HXs, failures in a PCHE are expected to be small cracks. If the faulted channel is blocked, it may have a positive function for plant safety because the pressure boundary would automatically recover due to this self-plugging. The other one is damage propagation on pressure boundary, which is referred to as potential wastage with combined corrosion/erosion effect. Physical/chemical phenomena that a slow loss of CO{sub 2} inventory into sodium after the sodium-CO{sub 2} boundary failure in printed circuit heat exchangers (PCHEs) were investigated. Our preliminary experimental results of plugging show that sodium flow immediately stopped as CO{sub 2} was injected through the nozzle at 300-400 .deg. C in 3 mm sodium channels, whereas sodium flow stopped about 60 min after CO{sub 2} injection in 5 mm sodium channels.

  6. Evaluation of steam-to-sodium leak detectors in the sodium components test installation (SCTI)

    Energy Technology Data Exchange (ETDEWEB)

    McKee, J M; Simmons, W R

    1975-07-01

    Two nickel diffusion-membrane type hydrogen detectors were installed in the secondary sodium system of the Sodium Components Test Installation and evaluated during the 12-month performance test of the Modular Steam Generator (MSG). Hydrogen in the expansion tank cover gas was monitored with a gas chromatograph. During this period, numerous steam and hydrogen injections were made, simulating steam leaks into the sodium of an LMFBR steam generator. The response of the detectors was evaluated for leak sizes ranging from 10{sup -6} to 10{sup -4} 1b H{sub 2}O/sec, injection periods of 0.5 to 300 min, secondary sodium flow rates of 0.2 x 10{sup 6} to 1.5 x 10{sup 6} 1b/hr, and sodium temperatures of 400 to 950 deg. F. The response of the leak detection system was influenced significantly by two regimes of sodium temperature. Below 600 deg. F, the cover gas hydrogen detector gave the largest response; this is attributed to the long dissolution time of hydrogen bubbles relative to the transit time of hydrogen to the expansion tank. Above 600 deg. F, the hydrogen apparently dissolved rapidly and the detectors were much more effective in the sodium than in the cover gas. At least 75% of the hydrogen and 50% of the oxygen content of injected steam appeared as detectable activity if the reaction products were dispersed in the sodium stream and the sodium was above 600 deg. F. Hydrogen injections into semi-stagnant sodium at the MSG tube sheets were detected with better sensitivity than steam injections into the main sodium stream. It appeared that high local concentrations of hydrogen were quickly carried to the nearest detector by upward currents created by the injected gas. The alarm system functioned as expected, 2.1 ppb/min being the smallest rate-of-rise in hydrogen concentration to give an automatic alarm. With more sensitive rate-of-rise alarm settings, leaks as small as 2 x 10{sup -5} 1b H{sub 2}O/sec could be detected in a system such as the Clinch River Breeder

  7. Evaluation of steam-to-sodium leak detectors in the sodium components test installation (SCTI)

    International Nuclear Information System (INIS)

    McKee, J.M.; Simmons, W.R.

    1975-01-01

    Two nickel diffusion-membrane type hydrogen detectors were installed in the secondary sodium system of the Sodium Components Test Installation and evaluated during the 12-month performance test of the Modular Steam Generator (MSG). Hydrogen in the expansion tank cover gas was monitored with a gas chromatograph. During this period, numerous steam and hydrogen injections were made, simulating steam leaks into the sodium of an LMFBR steam generator. The response of the detectors was evaluated for leak sizes ranging from 10 -6 to 10 -4 1b H 2 O/sec, injection periods of 0.5 to 300 min, secondary sodium flow rates of 0.2 x 10 6 to 1.5 x 10 6 1b/hr, and sodium temperatures of 400 to 950 deg. F. The response of the leak detection system was influenced significantly by two regimes of sodium temperature. Below 600 deg. F, the cover gas hydrogen detector gave the largest response; this is attributed to the long dissolution time of hydrogen bubbles relative to the transit time of hydrogen to the expansion tank. Above 600 deg. F, the hydrogen apparently dissolved rapidly and the detectors were much more effective in the sodium than in the cover gas. At least 75% of the hydrogen and 50% of the oxygen content of injected steam appeared as detectable activity if the reaction products were dispersed in the sodium stream and the sodium was above 600 deg. F. Hydrogen injections into semi-stagnant sodium at the MSG tube sheets were detected with better sensitivity than steam injections into the main sodium stream. It appeared that high local concentrations of hydrogen were quickly carried to the nearest detector by upward currents created by the injected gas. The alarm system functioned as expected, 2.1 ppb/min being the smallest rate-of-rise in hydrogen concentration to give an automatic alarm. With more sensitive rate-of-rise alarm settings, leaks as small as 2 x 10 -5 1b H 2 O/sec could be detected in a system such as the Clinch River Breeder Reactor Plant. A preliminary

  8. Nicolau Syndrome after Intramuscular Injection: 3 Cases

    Directory of Open Access Journals (Sweden)

    Seok-Kwun Kim

    2012-05-01

    Full Text Available Nicolau syndrome is a rare complication of intramuscular injection consisting of ischemic necrosis of skin, soft tissue, and muscular tissue that arises locoregionally. The characteristic pattern is pain around the injection site, developing into erythema, a livedoid dermatitis patch, and necrosis of the skin, subcutaneous fat, and muscle tissue. Three patients were injected with drugs (diclofenac sodium, ketoprofen, meperidine for pain relief. Three patients complained of pain, and a skin lesion was observed, after which necrosis developed on their buttocks. Each patient underwent debridement and coverage. The wound healed uneventfully. We report three cases of Nicolau syndrome in the buttocks following diclofenac intramuscular injection.

  9. Liquid sodium pool fires

    Energy Technology Data Exchange (ETDEWEB)

    Casselman, C [DSN/SESTR, Centre de Cadarache, Saint-Paul-lez-Durance (France)

    1979-03-01

    Experimental sodium pool combustion results have led to a definition of the combustion kinetics, and have revealed the hazards of sodium-concrete contact reactions and the possible ignition of organic matter (paint) by hydration of sodium peroxide aerosols. Analysis of these test results shows that the controlling mechanism is sodium evaporation diffusion. (author)

  10. Liquid sodium pool fires

    International Nuclear Information System (INIS)

    Casselman, C.

    1979-01-01

    Experimental sodium pool combustion results have led to a definition of the combustion kinetics, and have revealed the hazards of sodium-concrete contact reactions and the possible ignition of organic matter (paint) by hydration of sodium peroxide aerosols. Analysis of these test results shows that the controlling mechanism is sodium evaporation diffusion. (author)

  11. Teduglutide Injection

    Science.gov (United States)

    ... who need additional nutrition or fluids from intravenous (IV) therapy. Teduglutide injection is in a class of medications ... of the ingredients.tell your doctor and pharmacist what other prescription and nonprescription medications, vitamins, nutritional supplements, and herbal products you are taking ...

  12. Dexrazoxane Injection

    Science.gov (United States)

    ... are used to treat or prevent certain side effects that may be caused by chemotherapy medications. Dexrazoxane injection (Zinecard) is used to prevent or decrease heart damage caused by doxorubicin in women who are taking the medication to treat breast cancer that has spread to other parts of the ...

  13. Triptorelin Injection

    Science.gov (United States)

    ... puberty too soon, resulting in faster than normal bone growth and development of sexual characteristics) in children 2 years and older. Triptorelin injection is in a class of medications called gonadotropin-releasing hormone (GnRH) agonists. It works by decreasing the amount ...

  14. Small liquid sodium leaks

    International Nuclear Information System (INIS)

    Dufresne, J.; Rochedereux, Y.; Antonakas, D.; Casselman, C.; Malet, J.C.

    1986-05-01

    Usually, pessimistic considerations inassessing the safety of secondary sodium loops in LMFBR reactor lead to assume guillotine rupture releasing a large amount of sodium estimate the consequences of large sodium fires. In order to reduce these consequences, one has to detect the smallest leak as soon as possible and to evaluate the future of an initial small leak. Analysis of the relationship between crack size and sodium outflow rate; Analysis of a sodium pipe with a small open crack

  15. Experimental study on combustion and suppression characteristics of sodium fire in a columnar flow using extinguishing powder

    International Nuclear Information System (INIS)

    Huo Yan; Zhang Zhigang; Li Jinke; Liu Zhongkun; Ma Yaolong

    2017-01-01

    In the operation of the sodium-cooled fast reactor, the leakage and fire accident of liquid sodium is common and it is frequent in sodium-related facilities. This study focuses on the combustion and suppression characteristics of sodium fire in a columnar flow. Liquid sodium (250°C) is injected into a 7.9 m"3 cylindrical chamber at a flow rate of about 1.0 m"3/h to create a columnar sodium fire, and 18.4 kg class D extinguishing powder is sprayed after the liquid sodium injection. The temperature in the chamber space and sodium collection plate and the heat release rate from sodium fire are measured and analyzed. Based on the temperature data the sodium fire under suppression could be divided into four phases of dropping sharply, continuously remaining lower, rising and declining mildly, and depressing. The sodium fire in the space could be suppressed and cooled down if the extinguishing agent could spray in the early period of the liquid sodium injection. The extinguishing agent could suppress the combustion and spreading of liquid sodium dropping on the collection plate, limit the pool combustion area and postpone the commencement of sodium pool burning in spite of its later re-ignition happening. This study promises to evaluate the combustion and suppression characteristics of sodium fire in the sodium-related facilities. (author)

  16. The sodium process facility at Argonne National Laboratory - West

    International Nuclear Information System (INIS)

    Michelbacher, J.A.; Henslee, S.P.; McDermott, M.D.; Price, J.R.; Rosenberg, K.E.; Wells, P.B.

    1997-01-01

    Argonne National Laboratory - West (ANL-W) has approximately 680,000 liters (180,000 gallons) of raw sodium stored in facilities on site. As mandated by the State of Idaho and the United States Department of Energy (DOE), this sodium must be transformed into a stable condition for land disposal. To comply with this mandate, ANL-W designed and built the Sodium Process Facility (SPF) for the processing of this sodium into a dry, sodium carbonate powder. The major portion of the sodium stored at ANL-W is radioactively contaminated. The SPF was designed to react elemental sodium to sodium carbonate through two-stages involving caustic process and carbonate process steps. The sodium is first reacted to sodium hydroxide in the caustic process step. The caustic process step involves the injection of sodium into a nickel reaction vessel filled with a 50 wt% solution of sodium hydroxide. Water is also injected, controlling the boiling point of the solution. In the carbonate process, the sodium hydroxide is reacted with carbon dioxide to form sodium carbonate. This dry powder, similar in consistency to baking soda, is a waste form acceptable for burial in the State of Idaho as a non-hazardous, radioactive waste. The caustic process was originally designed and built in the 1980s for reacting the 290,000 liters (77,000 gallons) of primary sodium from the Fermi-1 Reactor to sodium hydroxide. The hydroxide was slated to be used to neutralize acid products from the PUREX process at the Hanford site. However, changes in the DOE mission precluded the need for hydroxide and the caustic process was never operated. With the shutdown of the Experimental Breeder Reactor-II (EBR-II), the necessity for a facility to react sodium was identified. In order to comply with Resource Conservation and Recovery Act (RCRA) requirements, the sodium had to be converted into a waste form acceptable for disposal in a Sub-Title D low-level radioactive waste disposal facility. Sodium hydroxide is a RCRA

  17. Naproxen sodium overdose

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/article/002507.htm Naproxen sodium overdose To use the sharing features on this page, please enable JavaScript. Naproxen sodium is a nonsteroidal anti-inflammatory drug (NSAID) used ...

  18. Sodium hydroxide poisoning

    Science.gov (United States)

    Sodium hydroxide is a very strong chemical. It is also known as lye and caustic soda. This ... poisoning from touching, breathing in (inhaling), or swallowing sodium hydroxide. This article is for information only. Do ...

  19. Sodium pumping: pump problems

    International Nuclear Information System (INIS)

    Guer, M.; Guiton, P.

    Information on sodium pumps for LMFBR type reactors is presented concerning ring pump design, pool reactor pump design, secondary pumps, sodium bearings, swivel joints of the oscillating annulus, and thermal shock loads

  20. Docusate Sodium and Pregnancy

    Science.gov (United States)

    ... a risk of miscarriage. Can use of docusate sodium during pregnancy cause birth defects? Few studies have been done to look at the possible risks of docusate sodium during pregnancy. However, the available studies show that when used ...

  1. Sodium carbonate poisoning

    Science.gov (United States)

    Sodium carbonate (known as washing soda or soda ash) is a chemical found in many household and industrial products. This article focuses on poisoning due to sodium carbonate. This article is for information only. Do NOT ...

  2. ELTA: Citatrademark: Sodium measurement

    International Nuclear Information System (INIS)

    Mauvais, O.

    2002-01-01

    ELTA is pleased to present its last model of Sodium analyzers: CITA 2340: Automatically controlled sodium meter, integrating more automation and performances results respecting costs and wastes reduction. (authors)

  3. Liquid sodium technology research

    International Nuclear Information System (INIS)

    Kim, W.C.; Lee, Y.W.; Nam, H.Y.; Chun, S.Y.; Kim, J.; Won, S.Y.

    1982-01-01

    This report describes the technology of impurity control and measurement of liquid sodium, problems associated with material degradation and change of heat transfer characteristics in liquid sodium, and the conceptual design of multipurpose sodium test loop. Discussion and the subsequent analysis are also made with regard to the test results for the sodium-H 2 0 reaction and its effects on the system. (author)

  4. Sodium sieving in children

    NARCIS (Netherlands)

    Rusthoven, Esther; Krediet, Raymond T.; Willems, Hans L.; Monnens, Leo A.; Schröder, Cornelis H.

    2005-01-01

    Sodium sieving is a consequence of dissociation between the amount of water and sodium transported over the peritoneal membrane. This dissociation occurs in the presence of aquaporin-mediated water transport. Sieving of sodium can be used as a rough measure for aquaporin-mediated water transport.

  5. Compatibility of ondansetron hydrochloride and methylprednisolone sodium succinate in multilayer polyolefin containers.

    Science.gov (United States)

    Bougouin, Christelle; Thelcide, Chloë; Crespin-Maillard, Fabienne; Maillard, Christian; Kinowski, Jean Marie; Favier, Mireille

    2005-10-01

    The compatibility of ondansetron hydrochloride and methylprednisolone sodium succinate in 5% dextrose injection and 0.9% sodium chloride injection was studied. Test solutions of ondansetron hydrochloride 0.16 mg/mL and methylprednisolone sodium succinate 2.4 mg/mL were prepared in triplicate and tested in duplicate. Total volumes of 4 and 2 mL of ondansetron hydrochloride solution and methylprednisolone sodium succinate solution, respectively, were added to 50-mL multilayer polyolefin bags containing 5% dextrose injection or 0.9% sodium chloride injection. Bags were stored for 24 hours at 20-25 degrees C and for 48 hours at 4-8 degrees C. Chemical compatibility was measured with high-performance liquid chromatography, and physical compatibility was determined visually. Ondansetron hydrochloride was stable for up to 24 hours at 20-25 degrees C and up to 48 hours at 4-8 degrees C. Methylprednisolone sodium succinate was stable for up to 48 hours at 4-8 degrees C. When stored at 20-25 degrees C, methylprednisolone sodium succinate was stable for up to 7 hours in 5% dextrose injection and up to 24 hours in 0.9% sodium chloride injection. Compatibility data for solutions containing ondansetron hydrochloride plus methylprednisolone sodium succinate revealed that each drug was stable for up to 24 hours at 20-25 degrees C and up to 48 hours at 4-8 degrees C. Ondansetron 0.16 mg/mL (as the hydrochloride) and methylprednisolone 2.4 mg/mL (as the sodium succinate) mixed in 50-mL multilayer polyolefin bags were stable in both 5% dextrose injection and 0.9% sodium chloride injection for up to 24 hours at 20-25 degrees C and up to 48 hours at 4-8 degrees C.

  6. 21 CFR 522.1642 - Oxymorphone hydrochloride injection.

    Science.gov (United States)

    2010-04-01

    ... § 522.1642 Oxymorphone hydrochloride injection. (a) Specifications. The drug contains 1 or 1.5 milligrams of oxymorphone hydrochloride per milliliter of aqueous solution containing 0.8 percent sodium... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Oxymorphone hydrochloride injection. 522.1642...

  7. Report of sodium cavitation

    International Nuclear Information System (INIS)

    Murai, Hitoshi; Shima, Akira; Oba, Toshisaburo; Kobayashi, Ryoji; Hashimoto, Hiroyuki

    1975-01-01

    The damage of components for LMFBRs due to sodium cavitation is serious problem. This report summarizes the following items, (1) mechanism of the incipience of sodium cavitation, (2) damage due to sodium cavitation, (3) detection method for sodium cavitation, and (4) estimation method for sodium cavitation by the comparison with water cavitation. Materials were collected from the reports on liquid metal cavitation, sodium cavitation and water cavitation published from 1965 to now. The mechanism of the incipience of sodium cavitation cavitation parameters (mean location, distributed amount or occurrence aspect and stability), experiment of causing cavitation with Venturi tube, and growth of bubbles within superheated sodium. The sodium cavitation damage was caused by magnetostriction vibration method and with Venturi tube. The state of damage was investigated with the cavitation performance of a sodium pump, and the damage was examined in view of the safety of LMFBR plants. Sodium cavitation was detected with acoustic method, radiation method, and electric method. The effect of physical property of liquid on incipient cavitation was studied. These are thermodynamic effect based on quasistatic thermal equilibrium condition and the effect of the physical property of liquid based on bubble dynamics. (Iwase, T.)

  8. Sodium safety manual

    International Nuclear Information System (INIS)

    Hayes, D.J.; Gardiner, R.L.

    1980-09-01

    The sodium safety manual is based upon more than a decade of experience with liquid sodium at Berkeley Nuclear Laboratories (BNL). It draws particularly from the expertise and experience developed in the course of research work into sodium fires and sodium water reactions. It draws also on information obtained from the UKAEA and other sodium users. Many of the broad principles will apply to other Establishments but much of the detail is specific to BNL and as a consequence its application at other sites may well be limited. Accidents with sodium are at best unpleasant and at worst lethal in an extremely painful way. The object of this manual is to help prevent sodium accidents. It is not intended to give detailed advice on specific precautions for particular situations, but rather to set out the overall strategy which will ensure that sodium activities will be pursued safely. More detail is generally conveyed to staff by the use of local instructions known as Sodium Working Procedures (SWP's) which are not reproduced in this manual although a list of current SWP's is included. Much attention is properly given to the safe design and operation of larger facilities; nevertheless evidence suggests that sodium accidents most frequently occur in small-scale work particularly in operations associated with sodium cleaning and special care is needed in all such cases. (U.K.)

  9. Safe injection procedures, injection practices, and needlestick ...

    African Journals Online (AJOL)

    Results: Safe injection procedures regarding final waste disposal were sufficiently adopted, while measures regarding disposable injection equipment, waste containers, hand hygiene, as well as injection practices were inadequately carried out. Lack of job aid posters that promote safe injection and safe disposal of ...

  10. Stability of sodium bicarbonate solutions in polyolefin bags.

    Science.gov (United States)

    Wear, Jennifer; McPherson, Timothy B; Kolling, William M

    2010-06-15

    The stability of sodium bicarbonate solutions in sterile water for injection or 5% dextrose injection stored at 21-24 degrees C or 2-4 degrees C was evaluated. Sodium bicarbonate injection was obtained in 50-mL vials of 8.4% (1 meq/mL). A total of 50, 100, or 150 meq of sodium bicarbonate was added to each 1-L polyolefin bag of either sterile water for injection or 5% dextrose injection. All solutions were prepared in a laminar-airflow hood using aseptic technique. Bags were punctured once to remove headspace air and once for the addition of each 50 meq of sodium bicarbonate. Six replicates of each test solution were prepared. The solutions were stored at 21-24 degrees C and 2-4 degrees C. Control solutions (50 and 150 meq) were similarly prepared in triplicate. Control solutions were sparged with either nitrogen gas or oxygen gas before storage. Sodium bicarbonate stability was assessed by measuring solution pH. Bicarbonate content was measured utilizing titration. Both pH and bicarbonate concentrations were measured immediately upon preparation and on days 3, 5, and 7 for both test and control solutions. All 95% confidence interval values for sample solution pH remained within 7.0-8.5 for seven days at 2-4 degrees C. Sodium bicarbonate solutions of 50, 100, and 150 meq in sterile water for injection or 5% dextrose injection were stable for up to seven days when refrigerated. The 50-meq solution was stable for up to 48 hours when stored at room temperature, and the 100- and 150-meq solutions were stable for up to 30 hours when stored at room temperature.

  11. Dialysate sodium and sodium gradient in maintenance hemodialysis: a neglected sodium restriction approach?

    OpenAIRE

    Munoz Mendoza, Jair; Sun, Sumi; Chertow, Glenn M.; Moran, John; Doss, Sheila; Schiller, Brigitte

    2011-01-01

    Background. A higher sodium gradient (dialysate sodium minus pre-dialysis plasma sodium) during hemodialysis (HD) has been associated with sodium loading; however, its role is not well studied. We hypothesized that a sodium dialysate prescription resulting in a higher sodium gradient is associated with increases in interdialytic weight gain (IDWG), blood pressure (BP) and thirst.

  12. Studies on generation and transport of sodium aerosols in some test facilities

    International Nuclear Information System (INIS)

    Sano, T.; Shimomura, T.; Hattori, N.

    1986-01-01

    Technical experiences that have been obtained during the course of the experiments to determine the sodium aerosol concentration, to study the deposition of sodium aerosol, and to predict mechanical properties of sodium vapor deposits are presented. In the first study, the sodium aerosol concentrations in an inert cover gas space over a sodium pool and those following a sodium spray injection into an inert atmosphere were determined. The results from the two different experiments were compared with each other and were discussed in comparison with those from the literature. In the second study, deposition of sodium aerosol following a sodium spray injection into an inert atmosphere was examined. The deposition rates on the walls and the floor of a closed concrete cell were measured, and the results obtained were discussed. The third study relates to the sodium vapor deposition within a narrow annulus. In the experiments, a downward argon gas flow that passes the annulus was fed to prevent sodium vapor deposition. Average sodium vapor deposition rates on the walls of the annulus were determined, then the effect of the downward feed gas was discussed. The last study relates to one of the mechanical properties and the deformation rate of solid sodium being compressed. The purpose of the experiments were to obtain data to predict deformation rate of the sodium deposits. (author)

  13. Small-Volume Injections: Evaluation of Volume Administration Deviation From Intended Injection Volumes.

    Science.gov (United States)

    Muffly, Matthew K; Chen, Michael I; Claure, Rebecca E; Drover, David R; Efron, Bradley; Fitch, William L; Hammer, Gregory B

    2017-10-01

    In the perioperative period, anesthesiologists and postanesthesia care unit (PACU) nurses routinely prepare and administer small-volume IV injections, yet the accuracy of delivered medication volumes in this setting has not been described. In this ex vivo study, we sought to characterize the degree to which small-volume injections (≤0.5 mL) deviated from the intended injection volumes among a group of pediatric anesthesiologists and pediatric postanesthesia care unit (PACU) nurses. We hypothesized that as the intended injection volumes decreased, the deviation from those intended injection volumes would increase. Ten attending pediatric anesthesiologists and 10 pediatric PACU nurses each performed a series of 10 injections into a simulated patient IV setup. Practitioners used separate 1-mL tuberculin syringes with removable 18-gauge needles (Becton-Dickinson & Company, Franklin Lakes, NJ) to aspirate 5 different volumes (0.025, 0.05, 0.1, 0.25, and 0.5 mL) of 0.25 mM Lucifer Yellow (LY) fluorescent dye constituted in saline (Sigma Aldrich, St. Louis, MO) from a rubber-stoppered vial. Each participant then injected the specified volume of LY fluorescent dye via a 3-way stopcock into IV tubing with free-flowing 0.9% sodium chloride (10 mL/min). The injected volume of LY fluorescent dye and 0.9% sodium chloride then drained into a collection vial for laboratory analysis. Microplate fluorescence wavelength detection (Infinite M1000; Tecan, Mannedorf, Switzerland) was used to measure the fluorescence of the collected fluid. Administered injection volumes were calculated based on the fluorescence of the collected fluid using a calibration curve of known LY volumes and associated fluorescence.To determine whether deviation of the administered volumes from the intended injection volumes increased at lower injection volumes, we compared the proportional injection volume error (loge [administered volume/intended volume]) for each of the 5 injection volumes using a linear

  14. Solubilities of sodium nitrate, sodium nitrite, and sodium aluminate in simulated nuclear waste

    International Nuclear Information System (INIS)

    Reynolds, D.A.; Herting, D.L.

    1984-09-01

    Solubilities were determined for sodium nitrate, sodium nitrite, and sodium aluminate in synthetic nuclear waste liquor. Solubilities were determined as a function of temperature and solution composition (concentrations of sodium hydroxide, sodium nitrate, sodium nitrite, and sodium aluminate). Temperature had the greatest effect on the solubilities of sodium nitrate and sodium nitrite and a somewhat lesser effect on sodium aluminate solubility. Hydroxide had a great effect on the solubilities of all three salts. Other solution components had minor effects. 2 references, 8 figures, 11 tables

  15. Sodium aerosol recovering device

    International Nuclear Information System (INIS)

    Fujimori, Koji; Ueda, Mitsuo; Tanaka, Kazuhisa.

    1997-01-01

    A main body of a recovering device is disposed in a sodium cooled reactor or a sodium cooled test device. Air containing sodium aerosol is sucked into the main body of the recovering device by a recycling fan and introduced to a multi-staged metal mesh filter portion. The air about against each of the metal mesh filters, and the sodium aerosol in the air is collected. The air having a reduced sodium aerosol concentration circulates passing through a recycling fan and pipelines to form a circulation air streams. Sodium aerosol deposited on each of the metal mesh filters is scraped off periodically by a scraper driving device to prevent clogging of each of the metal filters. (I.N.)

  16. [Sodium intake during pregnancy].

    Science.gov (United States)

    Delemarre, F M; Franx, A; Knuist, M; Steegers, E A

    1999-10-23

    International studies have yielded contradictory results on efficacy of a sodium-restricted diet during pregnancy in preventing and curing hypertension of pregnancy. In the Netherlands three studies have been performed to investigate the value of dietary sodium restriction in pregnancy; they concerned epidemiology, prevention and treatment. Midwives often prescribed this dietary intervention. Urinary sodium excretion was not related to blood pressure changes in pregnancy. Dietary sodium restriction from the third month of pregnancy onwards did not reduce the incidence of pregnancy-induced hypertension. Maternal side effects were a decreased intake of nutrients, decreased maternal weight gain, lowered plasma volume and stimulation of the renin-angiotensin-aldosterone system. A dietary sodium restriction in women with early symptoms of pregnancy-induced hypertension showed no therapeutic effect on blood pressure. There is no place for dietary sodium restriction in the prevention or treatment of hypertension in pregnancy.

  17. Sodium fire protection

    International Nuclear Information System (INIS)

    Raju, C.; Kale, R.D.

    1979-01-01

    Results of experiments carried out with sodium fires to develop extinguishment techniques are presented. Characteristics, ignition temperature, heat evolution and other aspects of sodium fires are described. Out of the powders tested for extinguishment of 10 Kg sodium fires, sodium bi-carbonate based dry chemical powder has been found to be the best extinguisher followed by large sized vermiculite and then calcium carbonate powders distributed by spray nozzles. Powders, however, do not extinguish large fires effectively due to sodium-concrete reaction. To control large scale fires in a LMFBR, collection trays with protective cover have been found to cause oxygen starvation better than flooding with inert gas. This system has an added advantage in that there is no damage to the sodium facilities as has been in the case of powders which often contain chlorine compounds and cause stress corrosion cracking. (M.G.B.)

  18. Sodium fire suppression

    Energy Technology Data Exchange (ETDEWEB)

    Malet, J C [DSN/SESTR, Centre de Cadarache, Saint-Paul-lez-Durance (France)

    1979-03-01

    Ignition and combustion studies have provided valuable data and guidelines for sodium fire suppression research. The primary necessity is to isolate the oxidant from the fuel, rather than to attempt to cool the sodium below its ignition temperature. Work along these lines has led to the development of smothering tank systems and a dry extinguishing powder. Based on the results obtained, the implementation of these techniques is discussed with regard to sodium fire suppression in the Super-Phenix reactor. (author)

  19. Sodium fire suppression

    International Nuclear Information System (INIS)

    Malet, J.C.

    1979-01-01

    Ignition and combustion studies have provided valuable data and guidelines for sodium fire suppression research. The primary necessity is to isolate the oxidant from the fuel, rather than to attempt to cool the sodium below its ignition temperature. Work along these lines has led to the development of smothering tank systems and a dry extinguishing powder. Based on the results obtained, the implementation of these techniques is discussed with regard to sodium fire suppression in the Super-Phenix reactor. (author)

  20. The effects of sodium bicarbonate during prolonged cardiopulmonary resuscitation.

    Science.gov (United States)

    Weng, Yi-Ming; Wu, Shih-Hao; Li, Wen-Cheng; Kuo, Chan-Wei; Chen, Shou-Yen; Chen, Jih-Chang

    2013-03-01

    This study was performed to determine the effects of sodium bicarbonate injection during prolonged cardiopulmonary resuscitation (for >15 minutes). The retrospective cohort study consisted of adult patients who presented to the emergency department (ED) with the diagnosis of cardiac arrest in 2009. Data were retrieved from the institutional database. A total of 92 patients were enrolled in the study. Patients were divided into 2 groups based on whether they were treated (group1, n = 30) or not treated (group 2, n = 62) with sodium bicarbonate. There were no significant differences in demographic characteristics between groups. The median time interval between the administration of CPR and sodium bicarbonate injection was 36.0 minutes (IQR: 30.5-41.8 minutes). The median amount of bicarbonate injection was 100.2 mEq (IQR: 66.8-104.4). Patients who received a sodium bicarbonate injection during prolonged CPR had a higher percentage of return of spontaneous circulation, but not statistical significant (ROSC, 40.0% vs. 32.3%; P = .465). Sustained ROSC was achieved by 2 (6.7%) patients in the sodium bicarbonate treatment group, with no survival to discharge. No significant differences in vital signs after ROSC were detected between the 2 groups (heart rate, P = .124; systolic blood pressure, P = .094). Sodium bicarbonate injection during prolonged CPR was not associated with ROSC after adjust for variables by regression analysis (Table 3; P = .615; odds ratio, 1.270; 95% confidence interval: 0.501-3.219) The administration of sodium bicarbonate during prolonged CPR did not significantly improve the rate of ROSC in out-of-hospital cardiac arrest. Copyright © 2013 Elsevier Inc. All rights reserved.

  1. Sodium fill of FFTF

    International Nuclear Information System (INIS)

    Waldo, J.B.; Greenwell, R.K.; Keasling, T.A.; Collins, J.R.; Klos, D.B.

    1980-02-01

    With construction of the Fast Flux Test Facility (FFTF) completed, the first major objective in the startup program was to fill the sodium systems. A sodium fill sequence was developed to match construction completion, and as systems became available, they were inerted, preheated, and filled with sodium. The secondary sodium systems were filled first while dry refueling system testing was in progress in the reactor vessel. The reactor vessel and the primary loops were filled last. This paper describes the methods used and some of the key results achieved for this major FFTF objective

  2. Fires of sodium installations

    International Nuclear Information System (INIS)

    Hajek, L.; Tlalka, R.

    1984-01-01

    A survey is presented of the literature dealing with fires of sodium installations between 1974 and 1981. Also described are three experimental fires of ca 50 kg of sodium in an open area, monitored by UJV Rez. The experimental conditions of the experiments are described and a phenomenological description is presented of the course of the fires. The experiments showed a relationship between wind velocity in the area surrounding the fire and surface temperature of the sodium flame. Systems analysis methods were applied to sodium area, spray and tube fires. (author)

  3. Safe injection procedures, injection practices, and needlestick ...

    African Journals Online (AJOL)

    Nermine Mohamed Tawfik Foda

    2017-01-10

    Jan 10, 2017 ... sures regarding disposable injection equipment, waste containers, hand hygiene ... injection practices lead to high prevalence of NSSIs in operating rooms. .... guidelines, the availability of training courses to HCWs, and provi-.

  4. Development of Sodium Technology for LMR

    Energy Technology Data Exchange (ETDEWEB)

    Kim, B. H.; Nam, H. Y.; Kim, T. J. (and others)

    2007-03-15

    In the experiments to investigate the characteristics of the free surface fluctuation in a vessel, the experimental correlation was modeled to describe the free surface fluctuation in the upper plenum of a liquid metal reactor within 95% reliability and 2.4% error. The correlation was used to verify the computational model. The new conceptual flowmeters were suggested to measure the sodium flow for the reliability enhancement. The electromagnetic flowmeter with permanent magnet showed a good linearity and repeatability. For reuse of the sodium contaminated component, CO{sub 2} bubbling method was developed. Sodium in 0.3mm crevice specimen was removed completely. The optimum condition for the used sodium treatment was deduced to estimate which reaction is more safe and adequate for operation condition by analyzing the reactivity alleviation condition and the reaction rate with the control of sodium hydroxide concentration A series of tests were carried out to investigate the enlargement rate of the nozzle hole itself and the sodium-water reaction temperature associated with needle-like jets of a high-pressure water/steam into the sodium side of a steam generator. The size of the nozzle hole became larger with an increased duration of the steam injection both for the 2.25Cr-1Mo and M9Cr-1Mo steels by a self-wastage phenomenon. For developing the SWR acoustic leak detection technology, the tool prepared by the LabVIEW was installed with the system, and confirmed the performance of the on-line acoustic leak detection tool using the SWR leak signal acquired in the KAERI facility.

  5. Visibility in sodium fume

    International Nuclear Information System (INIS)

    Hughes, G.W.; Anderson, N.R.

    1971-01-01

    The appearance of sodium fume of unknown concentration and the effects of short term exposure on unprotected workers is described. The molecular extinction coefficient of sodium fume is calculated from which light transmission data, and a rapid method for the estimation of the fume concentration is proposed. (author)

  6. Sodium outleakage detection

    International Nuclear Information System (INIS)

    Casselman, C.

    1979-01-01

    Effective detection of outleakage from sodium facilities permits timely intervention capable of limiting the consequences of such leakage. Two types of detection systems are described: local and overall detection. The use of two independent systems in sodium facilities is recommended. (author)

  7. Annular sodium flowsensor

    International Nuclear Information System (INIS)

    Kaiser, W.C.; Brewer, J.; Forster, G.A.

    1983-01-01

    This paper describes a unique eddy-current type liquid sodium flowsensor, designed as a joint effort between Argonne National Laboratory and Kaman Instrumentation Corp. Test results are included for operation of the flowsensor mounted on a sodium test loop whose configuration simulates the actual operating conditions, except for the magnetic field of the ALIP

  8. Injection Laryngoplasty Materials

    OpenAIRE

    Haldun Oðuz

    2013-01-01

    Injection laryngoplasty is one of the treatment options for voice problems. In the recent years, more safe and more biocompatible injection materials are available on the market. Long and short term injection materials are discussed in this review.

  9. Penicillin G Procaine Injection

    Science.gov (United States)

    Penicillin G procaine injection is used to treat certain infections caused by bacteria. Penicillin G procaine injection should not be used to ... early in the treatment of certain serious infections. Penicillin G procaine injection is in a class of ...

  10. Rapid colorimetric assay for gentamicin injection.

    Science.gov (United States)

    Tarbutton, P

    1987-01-01

    A rapid colorimetric method for determining gentamicin concentration in commercial preparations of gentamicin sulfate injection was developed. Methods currently available for measuring gentamicin concentration via its colored complex with cupric ions in alkaline solution were modified to reduce the time required for a single analysis. The alkaline copper tartrate (ACT) reagent solution was prepared such that each milliliter contained 100 mumol cupric sulfate, 210 mumol potassium sodium tartrate, and 1.25 mmol sodium hydroxide. The assay involves mixing 0.3 mL gentamicin sulfate injection 40 mg/mL (of gentamicin), 1.0 mL ACT reagent, and 0.7 mL water; the absorbance of the resulting solution at 560 nm was used to calculate the gentamicin concentration in the sample. For injections containing 10 mg/mL of gentamicin, the amount of the injection was increased to 0.5 mL and water decreased to 0.5 mL. The concentration of gentamicin in samples representing 11 lots of gentamicin sulfate injection 40 mg/mL and 8 lots of gentamicin sulfate injection 10 mg/mL was determined. The specificity, reproducibility, and accuracy of the assay were assessed. The colored complex was stable for at least two hours. Gentamicin concentration ranged from 93.7 to 108% and from 95 to 109% of the stated label value of the 40 mg/mL and the 10 mg/mL injections, respectively. No components of the preservative system present in the injections interfered with the assay. Since other aminoglycosides produced a colored complex, the assay is not specific for gentamicin. The assay was accurate and reproducible over the range of 4-20 mg of gentamicin. This rapid and accurate assay can be easily applied in the hospital pharmacy setting.

  11. Nicolau Syndrome after Intramuscular Injection: 3 Cases

    Directory of Open Access Journals (Sweden)

    Seok-Kwun Kim

    2012-05-01

    Full Text Available Nicolau syndrome is a rare complication of intramuscular injection consisting of ischemicnecrosis of skin, soft tissue, and muscular tissue that arises locoregionally. The characteristicpattern is pain around the injection site, developing into erythema, a livedoid dermatitispatch, and necrosis of the skin, subcutaneous fat, and muscle tissue. Three patients wereinjected with drugs (diclofenac sodium, ketoprofen, meperidine for pain relief. Three patientscomplained of pain, and a skin lesion was observed, after which necrosis developed on theirbuttocks. Each patient underwent debridement and coverage. The wound healed uneventfully.We report three cases of Nicolau syndrome in the buttocks following diclofenac intramuscularinjection.

  12. Injection profiles with radiation induced copolymers

    International Nuclear Information System (INIS)

    Knight, B.L.; Rhudy, J.S.; Gogarty, W.B.

    1976-01-01

    The injectivity profile of a heterogeneous formation and/or vertical conformance is improved by injecting an aqueous solution into the formation, the solution containing a polymer obtained as a product of radiation-induced polymerization of acrylamide and/or methacrylamide and acrylic acid, methacrylic acid, and/or alkali metal salts thereof. The polymerization is preferably carried out in a 10 to 60 percent aqueous solution with gamma radiation; the aqueous monomer solution preferably contains 25 to 99 percent acrylamide and 1 to 75 percent sodium acrylate. Immiscible, miscible, or miscible-like displacing processes can be used in conjunction with this invention. 20 claims

  13. Total-body sodium and sodium excess

    International Nuclear Information System (INIS)

    Aloia, J.F.; Cohn, S.H.; Abesamis, C.; Babu, T.; Zanzi, I.; Ellis, K.

    1980-01-01

    Total-body levels of sodium (TBNa), chlorine (TBCI), calcium (TBCa), and potassium (TBK) were measured by neutron activation and analysis of results by whole body counting in 66 postmenopausal women. The relationship between TBNa, and TBCl, TBK, and TBCa on the one hand, and height and weight on the other, were found to compare with those previously reported. The hypothesis that TBNa and TBCl are distributed normally could not be rejected. The sodium excess (Na/sub es/) is defined as the sodium that is present in excess of that associated with the extracellular fluid (chlorine) space; the Na/sub es/ approximates nonexchangeable bone sodium. In these 66 postmenopausal women, and in patients with different endocrinopathies previously described, the values on Na/sub es/ did not differ from the normal values except in the thyrotoxicosis patients, where they were decreased. A close relationship between Na/sub es/ and TBCa was maintained in the endocrinopathies studied. This relationship was found in conditions accompanied by either an increment or a loss of skeletal mass. It appears that the NA/sub es/ value is primarily dependent upon the calcium content of bone

  14. 21 CFR 522.1704 - Sodium pentobarbital injection.

    Science.gov (United States)

    2010-04-01

    ... 522.1704 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... general anesthetic in dogs and cats. Although it may be used as a general surgical anesthetic for horses... local anesthetic. It may also be used in dogs for the symptomatic treatment of strychnine poisoning. (ii...

  15. Sodium Carbonate is Saltier Than Sodium Chloride to Sodium-Depleted Rats.

    Science.gov (United States)

    St John, Steven J; McBrayer, Anya M; Krauskopf, Erin E

    2017-10-01

    In a series of behavioral experiments in the 1960s, G.R. Morrison identified several unique features of the taste of Na2CO3 to rats; namely, it is 1) considerably more intense than NaCl at isomolar concentrations, 2) avoided at 10 times lower concentrations than NaCl to thirsty rats, 3) preferred at 10 times lower concentrations than NaCl in sodium-depleted rats. He also demonstrated its qualitatively similarity to NaCl. In Experiment 1, we confirmed and extended many of Morrison's observations. Rats were injected with furosemide on 3 occasions to stimulate a sodium appetite. After each depletion, rats were given a brief-access taste test in a lickometer presenting, in random order, water and 7 concentrations of salt. One test used NaCl (0.028-0.89 M, quarter log steps), another used Na2CO3, and the third used Na2CO3, but at a tenfold lower concentration range (0.0028-0.089 M). Rats licked NaCl in an inverted-U shaped concentration-response function peaking at 0.158-0.281 M. As Morrison's results predicted, rats licked Na2CO3 in nearly identical fashion, but at a tenfold lower concentration range (peak at 0.0158-0.028 M). In a second experiment, furosemide-treated rats were repeatedly tested with the lower Na2CO3 range but mixed in the epithelial sodium channel blocker amiloride at various concentrations (3-300 μM, half log steps). Amiloride reduced licking for Na2CO3 and shifted the peak response rightward up to about half a log unit. Thus, this "super-saltiness" of Na2CO3 to rats is at least partly amiloride-dependent. © The Author 2017. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  16. Final report on the safety assessment of sodium sulfite, potassium sulfite, ammonium sulfite, sodium bisulfite, ammonium bisulfite, sodium metabisulfite and potassium metabisulfite.

    Science.gov (United States)

    Nair, Bindu; Elmore, Amy R

    2003-01-01

    Sodium Sulfite, Ammonium Sulfite, Sodium Bisulfite, Potassium Bisulfite, Ammonium Bisulfite, Sodium Metabisulfite, and Potassium Metabisulfite are inorganic salts that function as reducing agents in cosmetic formulations. All except Sodium Metabisulfite also function as hair-waving/straightening agents. In addition, Sodium Sulfite, Potassium Sulfite, Sodium Bisulfite, and Sodium Metabisulfite function as antioxidants. Although Ammonium Sulfite is not in current use, the others are widely used in hair care products. Sulfites that enter mammals via ingestion, inhalation, or injection are metabolized by sulfite oxidase to sulfate. In oral-dose animal toxicity studies, hyperplastic changes in the gastric mucosa were the most common findings at high doses. Ammonium Sulfite aerosol had an acute LC(50) of >400 mg/m(3) in guinea pigs. A single exposure to low concentrations of a Sodium Sulfite fine aerosol produced dose-related changes in the lung capacity parameters of guinea pigs. A 3-day exposure of rats to a Sodium Sulfite fine aerosol produced mild pulmonary edema and irritation of the tracheal epithelium. Severe epithelial changes were observed in dogs exposed for 290 days to 1 mg/m(3) of a Sodium Metabisulfite fine aerosol. These fine aerosols contained fine respirable particle sizes that are not found in cosmetic aerosols or pump sprays. None of the cosmetic product types, however, in which these ingredients are used are aerosolized. Sodium Bisulfite (tested at 38%) and Sodium Metabisulfite (undiluted) were not irritants to rabbits following occlusive exposures. Sodium Metabisulfite (tested at 50%) was irritating to guinea pigs following repeated exposure. In rats, Sodium Sulfite heptahydrate at large doses (up to 3.3 g/kg) produced fetal toxicity but not teratogenicity. Sodium Bisulfite, Sodium Metabisulfite, and Potassium Metabisulfite were not teratogenic for mice, rats, hamsters, or rabbits at doses up to 160 mg/kg. Generally, Sodium Sulfite, Sodium

  17. Methodology for Extraction of Remaining Sodium of Used Sodium Containers

    International Nuclear Information System (INIS)

    Jung, Minhwan; Kim, Jongman; Cho, Youngil; Jeong, Jiyoung

    2014-01-01

    Sodium used as a coolant in the SFR (Sodium-cooled Fast Reactor) reacts easily with most elements due to its high reactivity. If sodium at high temperature leaks outside of a system boundary and makes contact with oxygen, it starts to burn and toxic aerosols are produced. In addition, it generates flammable hydrogen gas through a reaction with water. Hydrogen gas can be explosive within the range of 4.75 vol%. Therefore, the sodium should be handled carefully in accordance with standard procedures even though there is a small amount of target sodium remainings inside the containers and drums used for experiment. After the experiment, all sodium experimental apparatuses should be dismantled carefully through a series of draining, residual sodium extraction, and cleaning if they are no longer reused. In this work, a system for the extraction of the remaining sodium of used sodium drums has been developed and an operation procedure for the system has been established. In this work, a methodology for the extraction of remaining sodium out of the used sodium container has been developed as one of the sodium facility maintenance works. The sodium extraction system for remaining sodium of the used drums was designed and tested successfully. This work will contribute to an establishment of sodium handling technology for PGSFR. (Prototype Gen-IV Sodium-cooled Fast Reactor)

  18. Sodium oxide aerosol filtration

    Energy Technology Data Exchange (ETDEWEB)

    Duverger de Cuy, G [DSN/SESTR, Centre de Cadarache, Saint-Paul-lez-Durance (France)

    1979-03-01

    In the scope of the sodium aerosol trapping research effort by the CEA/DSN, the retention capacity and yield were measured for very high efficiency fiberglass filters and several types of prefilters (cyclone agglomerator, fabric prefilters, water scrubbers). (author)

  19. Sodium oxide aerosol filtration

    International Nuclear Information System (INIS)

    Duverger de Cuy, G.

    1979-01-01

    In the scope of the sodium aerosol trapping research effort by the CEA/DSN, the retention capacity and yield were measured for very high efficiency fiberglass filters and several types of prefilters (cyclone agglomerator, fabric prefilters, water scrubbers). (author)

  20. Sodium distiller II

    International Nuclear Information System (INIS)

    Goncalves, A.C.; Castro, P.M. e; Torres, A.R.; Correa, S.M.

    1990-01-01

    A sodium distiller allows the evaluation of the sodium purity, contained in plants and circuits of Fast Reactors. The sodium distillers of the IEN Reactor's Department was developed initially as a prototype, for the testing of the distillation process and in a second step, as a equipment dedicated to attendance the operation of these circuits. This last one was build in stainless steel, with external heat, rotating crucible of nickel for four samples, purge system for pipe cleaning and a sight glass that permits the observation of the distillation during all the operation. The major advantage of this equipment is the short time to do a distillation operation, which permits its routine utilization. As a consequence of the development of the distillers and its auxiliary systems an important amount of new information was gathered concerning components and systems behaviour under high temperature, vacuum and sodium. (author)

  1. Sodium hypochlorite poisoning

    Science.gov (United States)

    ... that can cause choking and serious breathing problems. Symptoms of sodium hypochlorite poisoning may include: Burning, red eyes Chest pain Coma Coughing (from the fumes) Delirium Gagging sensation Low blood pressure Pain in the ...

  2. Liquid sodium oxygenmeter

    International Nuclear Information System (INIS)

    Jakes, D.; Fresl, M.; Svoboda, V.

    1979-02-01

    The results of test runs of two design varieties of liquid sodium oxygenmeter in sodium loops are described. The accuracy and sensitivity are discussed reached using this instrument within 1 and 10 p.p.m. of oxygen concentration. A change in the used reference system is proposed based on practical experiences and thermochemical calculations. Ceramic electrolyte corrosion is analysed and the possible interpretation of the corrosion effect on the galvanic cell electromotive force is suggested. (author)

  3. Too Much Sodium

    Centers for Disease Control (CDC) Podcasts

    This podcast is based on the February 2012 CDC Vital Signs report. Ninety percent of Americans age two and older eat too much sodium which can increase your risk for high blood pressure and often leads to heart disease and stroke, two leading causes of death in the US. Learn several small steps you can take to reduce the amount of sodium in your diet.

  4. The analgesic effect of diclofenac sodium administered via the ...

    African Journals Online (AJOL)

    ... investigate the characteristics of the analgesic effect of diclofenac sodium injected epidurally in single or repeated doses and whether tolerance develops in long‑term use. Materials and Methods: A total of 30 rats were included in the study. The rats were anesthetized using intraperitoneal ketamine hydrochloride and an ...

  5. Final report on the safety assessment of potassium silicate, sodium metasilicate, and sodium silicate.

    Science.gov (United States)

    Elmore, Amy R

    2005-01-01

    Metasilicate, and Sodium Silicate ranged from negligible to severe, depending on the species tested and the molar ratio and concentration tested. Sodium Metasilicate was negative in the local lymph node assay (LLNA), but a delayed-type hypersensitivity response was observed in mice. Potassium Silicate was nonirritating in two acute eye irritation studies in rabbits. Sodium Metasilicate (42.4% H2O) was corrosive to the rabbit eye. Sodium Silicate was a severe eye irritant in some eye irritation studies, but was irritating or nonirritating in others. A skin freshener containing Sodium Silicate was nonirritating. Sodium Metasilicate was nonmutagenic in bacterial cells. Rats given Sodium Silicate (600 and 1200 ppm of added silica) in the drinking water in reproductive studies produced a reduced number of offspring: to 67% of controls at 600 ppm and to 80% of controls at 1200 ppm. Three adult rats injected intratesticularly and subcutaneously with 0.8 mM/kg of Sodium Silicate showed no morphological changes in the testes and no effect on the residual spermatozoa in the ductus deferens. Sodium Metasilicate (37% in a detergent) mixed with water was a severe skin irritant when tested on intact and abraded human skin, but 6%, 7%, and 13% Sodium Silicate were negligible skin irritants to intact and abraded human skin. Sodium Silicate (10% of a 40% aqueous solution) was negative in a repeat-insult predictive patch test in humans. The same aqueous solution of Sodium Silicate was considered a mild irritant under normal use conditions in a study of cumulative irritant properties. The Cosmetic Ingredient Review (CIR) Expert Panel recognized the irritation potential of these ingredients, especially in leave-on products. However, because these ingredients have limited dermal absorption and Sodium Metasilicate is a GRAS direct food substance, the Panel deemed the ingredients safe for use in cosmetic products in the practices of use and concentration described in this safety assessment, when

  6. Sodium fires and its extinguishment

    International Nuclear Information System (INIS)

    Mikhedov, V.G.

    1979-01-01

    The fire safety problems of NPP with sodium coolants in USSR are presented. The design of sodium reactors is made with premises with sodium coolants being hermetic and filled with nitrogen. Some engineering solutions of fire safety including design, elaboration and choice of construction and protection materials are presented. Some theoretical aspects of sodium burning are presented as well as methods of sodium fire extinguishing methods including the use of powder

  7. Safe injection procedures, injection practices, and needlestick ...

    African Journals Online (AJOL)

    Nermine Mohamed Tawfik Foda

    2017-01-10

    Jan 10, 2017 ... Background: Of the estimated 384,000 needle-stick injuries occurring in hospitals each year, 23% occur in surgical settings. This study was conducted to assess safe injection procedures, injection practices, and circumstances contributing to needlestick and sharps injures (NSSIs) in operating rooms.

  8. Accidental intra-arterial injection of fluorescein dye.

    Science.gov (United States)

    Bovino, J A; Marcus, D F

    1984-12-01

    During fluorescein angiography, sodium fluorescein dye intended for intravenous use was inadvertently injected into an artery in the antecubital fossa. An immediate and dramatic orange discoloration of the skin distal to the injection combined with intense burning pain of the right forearm and hand were noted. The patient was treated with ice packs and analgesics. The fluorescein angiogram showed a delayed arm to eye circulation time, but was of normal quality. There were no long-term complications.

  9. Endocrine control of active sodium transport across frog skin

    International Nuclear Information System (INIS)

    Maetz, J.

    1959-01-01

    I. Action of the neurohypophyseal peptides on sodium transport. 1) On Rana Esculenta, oxytocin alone is active on the sodium transport (not vaso pressin). 2) The post hypophysis of R.e. contains an hormonal factor even more specific on Na transport (12 times more active than oxytocin). 3) This new factor must be closely related to oxytocin. II. Action of the adrenal corticoids. 1) The skin of frogs adapted to a salt-rich external medium, shows a considerable diminution in sodium uptake. 2) This decreased sodium uptake is brought back to normal by the injections of aldosterone. 3) This suggests that salt loading of amphibians (as well as mammals) inhibits the mineralocorticoid activity of the adrenals. (author) [fr

  10. Development of sodium technology

    International Nuclear Information System (INIS)

    Hwang, Sung Tai; Nam, H. Y.; Choi, Y. D.

    2000-05-01

    The objective of present study is to produce the experimental data for development and verification of computer codes for development of LMR and to develop the preliminary technologies for the future large scale verification experiments. A MHD experimental test loop has been constructed for the quantitative analysis of the effect of magnetic field on the sodium flow and experiments are carried out for three EM pumps. The previous pressure drop correlations are evaluated using the experimental data obtained from the pressure drop experiment in a 19-pin fuel assembly with wire spacer. An dimensionless variable is proposed to describe the amplitude and frequency of the fluctuation of free surface using the experimental data obtained from free surface experimental apparatus and an empirical correlation is developed using this dimensionless variable. An experimental test loop is constructed to measure the flow characteristics in IHX shell side and the local pressure drop in fuel assembly, and to test the vibration behaviour of fuel pins due to flow induced vibration. The sodium two-phase flow measuring technique using the electromagnetic flowmeter is developed and the sodium differential pressure drop measuring technique using the method of direct contact of sodium and oil is established. The work on the analysis of sodium fire characteristics and produce data for vlidation of computer code is performed. Perfect reopen time of self plugged leak path was observed to be about 130 minutes after water leak initiation. Reopen shape of a specimen appeared to be double layer of circular type, and reopen size of this specimen surface was about 2mm diameter on sodium side. In small water leakage experiments, the following correlation equation about the reopen time between sodium temperature and initial leak rate was obtained, τ c = δ·g -0.83 ·10 (3570/T Na -3.34) , in 400-500 deg C of liquid sodium atmosphere. The characteristics of pressure propagation and gas flow, and

  11. Development of sodium technology

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Sung Tai; Nam, H Y; Choi, Y D [and others

    2000-05-01

    The objective of present study is to produce the experimental data for development and verification of computer codes for development of LMR and to develop the preliminary technologies for the future large scale verification experiments. A MHD experimental test loop has been constructed for the quantitative analysis of the effect of magnetic field on the sodium flow and experiments are carried out for three EM pumps. The previous pressure drop correlations are evaluated using the experimental data obtained from the pressure drop experiment in a 19-pin fuel assembly with wire spacer. An dimensionless variable is proposed to describe the amplitude and frequency of the fluctuation of free surface using the experimental data obtained from free surface experimental apparatus and an empirical correlation is developed using this dimensionless variable. An experimental test loop is constructed to measure the flow characteristics in IHX shell side and the local pressure drop in fuel assembly, and to test the vibration behaviour of fuel pins due to flow induced vibration. The sodium two-phase flow measuring technique using the electromagnetic flowmeter is developed and the sodium differential pressure drop measuring technique using the method of direct contact of sodium and oil is established. The work on the analysis of sodium fire characteristics and produce data for vlidation of computer code is performed. Perfect reopen time of self plugged leak path was observed to be about 130 minutes after water leak initiation. Reopen shape of a specimen appeared to be double layer of circular type, and reopen size of this specimen surface was about 2mm diameter on sodium side. In small water leakage experiments, the following correlation equation about the reopen time between sodium temperature and initial leak rate was obtained, {tau}{sub c} = {delta}{center_dot}g{sup -0.83}{center_dot}10{sup (3570/T{sub Na}-3.34)}, in 400-500 deg C of liquid sodium atmosphere. The characteristics

  12. Introduction of Sodium Fire Extinguishing System for STELLA-1

    International Nuclear Information System (INIS)

    Gam, Dayoung; Kim, Jong-Man; Jung, Min-Hwan; Eoh, Jae-Hyuk; Jeong, Eoh Jiyoung

    2015-01-01

    This characteristic is a big advantage as a thermal transfer fluid. However, the high reactivity of sodium, especially with water and oxygen, and white aerosol in the event of fire can cause serious accidents. Thus, large sodium facility needs a specific-developed fire extinguishing system for a safe experiment. Korea Atomic Energy Research Institute (KAERI) has conducted sodium heat transfer experiments using the facility named the Sodium Integral Effect Test Loop for Safety Simulation and Assessment (STELLA-1). STELLA-1 fully equipped a sodium fire extinguishing system for the safe experiment and fire spread prevention. In this paper, a preparation of the fire extinguishing system of STELLA-1 facility is introduced. This paper can provide an example of how to design a sodium fire extinguishing system for a large sodium experiment facility. In this paper, a preparation of the fire extinguishment system for STELLA-1 as a large sodium experiment facility was introduced and explained. For safe operation of the liquid sodium utility, it is important to equip specific-developed fire extinguishing system because of the chemical characteristics of sodium. Operators should know the process and operating manual before conducting an experiment to prevent hazardous situation. Though the dry chemical extinguishing agent put out the fire target, removing agent at high temperature state can cause re-combustion. Thus, extinguishment confirmation work should be conducted after sufficient cooling time to stabilize the surface. And in case of fire at a sealed room, a method making the percentage of oxygen low(injecting nitrogen gas or argon gas) is effective

  13. Introduction of Sodium Fire Extinguishing System for STELLA-1

    Energy Technology Data Exchange (ETDEWEB)

    Gam, Dayoung; Kim, Jong-Man; Jung, Min-Hwan; Eoh, Jae-Hyuk; Jeong, Eoh Jiyoung [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-05-15

    This characteristic is a big advantage as a thermal transfer fluid. However, the high reactivity of sodium, especially with water and oxygen, and white aerosol in the event of fire can cause serious accidents. Thus, large sodium facility needs a specific-developed fire extinguishing system for a safe experiment. Korea Atomic Energy Research Institute (KAERI) has conducted sodium heat transfer experiments using the facility named the Sodium Integral Effect Test Loop for Safety Simulation and Assessment (STELLA-1). STELLA-1 fully equipped a sodium fire extinguishing system for the safe experiment and fire spread prevention. In this paper, a preparation of the fire extinguishing system of STELLA-1 facility is introduced. This paper can provide an example of how to design a sodium fire extinguishing system for a large sodium experiment facility. In this paper, a preparation of the fire extinguishment system for STELLA-1 as a large sodium experiment facility was introduced and explained. For safe operation of the liquid sodium utility, it is important to equip specific-developed fire extinguishing system because of the chemical characteristics of sodium. Operators should know the process and operating manual before conducting an experiment to prevent hazardous situation. Though the dry chemical extinguishing agent put out the fire target, removing agent at high temperature state can cause re-combustion. Thus, extinguishment confirmation work should be conducted after sufficient cooling time to stabilize the surface. And in case of fire at a sealed room, a method making the percentage of oxygen low(injecting nitrogen gas or argon gas) is effective.

  14. Nitrocobinamide, a New Cyanide Antidote That Can Be Administered by Intramuscular Injection

    Science.gov (United States)

    Chan, Adriano; Jiang, Jingjing; Fridman, Alla; Guo, Ling T.; Shelton, G. Diane; Liu, Ming-Tao; Green, Carol; Haushalter, Kristofer J.; Patel, Hemal H.; Lee, Jangwoen; Yoon, David; Burney, Tanya; Mukai, David; Mahon, Sari B.; Brenner, Matthew; Pilz, Renate B.; Boss, Gerry R.

    2015-01-01

    Currently available cyanide antidotes must be given by intravenous injection over 5–10 min, making them illsuited for treating many people in the field, as could occur in a major fire, an industrial accident, or a terrorist attack. These scenarios call for a drug that can be given quickly, e.g., by intramuscular injection. We have shown that aquohydroxocobinamide is a potent cyanide antidote in animal models of cyanide poisoning, but it is unstable in solution and poorly absorbed after intramuscular injection. Here we show that adding sodium nitrite to cobinamide yields a stable derivative (referred to as nitrocobinamide) that rescues cyanide-poisoned mice and rabbits when given by intramuscular injection. We also show that the efficacy of nitrocobinamide is markedly enhanced by coadministering sodium thiosulfate (reducing the total injected volume), and we calculate that ∼1.4 mL each of nitrocobinamide and sodium thiosulfate should rescue a human from a lethal cyanide exposure. PMID:25650735

  15. Metaflumizone is a novel sodium channel blocker insecticide.

    Science.gov (United States)

    Salgado, V L; Hayashi, J H

    2007-12-15

    Metaflumizone is a novel semicarbazone insecticide, derived chemically from the pyrazoline sodium channel blocker insecticides (SCBIs) discovered at Philips-Duphar in the early 1970s, but with greatly improved mammalian safety. This paper describes studies confirming that the insecticidal action of metaflumizone is due to the state-dependent blockage of sodium channels. Larvae of the moth Spodoptera eridania injected with metaflumizone became paralyzed, concomitant with blockage of all nerve activity. Furthermore, tonic firing of abdominal stretch receptor organs from Spodoptera frugiperda was blocked by metaflumizone applied in the bath, consistent with the block of voltage-dependent sodium channels. Studies on native sodium channels, in primary-cultured neurons isolated from the CNS of the larvae of the moth Manduca sexta and on Para/TipE sodium channels heterologously expressed in Xenopus (African clawed frog) oocytes, confirmed that metaflumizone blocks sodium channels by binding selectively to the slow-inactivated state, which is characteristic of the SCBIs. The results confirm that metaflumizone is a novel sodium channel blocker insecticide.

  16. Calcitonin Salmon Injection

    Science.gov (United States)

    Calcitonin salmon injection is used to treat osteoporosis in postmenopausal women. Osteoporosis is a disease that causes bones to weaken and break more easily. Calcitonin salmon injection is also used to treat Paget's disease ...

  17. Iron Dextran Injection

    Science.gov (United States)

    Iron dextran injection is used to treat iron-deficiency anemia (a lower than normal number of red blood cells ... treated with iron supplements taken by mouth. Iron dextran injection is in a class of medications called ...

  18. Aminocaproic Acid Injection

    Science.gov (United States)

    Aminocaproic acid injection is used to control bleeding that occurs when blood clots are broken down too quickly. This ... the baby is ready to be born). Aminocaproic acid injection is also used to control bleeding in ...

  19. Deoxycholic Acid Injection

    Science.gov (United States)

    Deoxycholic acid injection is used to improve the appearance and profile of moderate to severe submental fat ('double chin'; fatty tissue located under the chin). Deoxycholic acid injection is in a class of medications called ...

  20. Cluster beam injection

    International Nuclear Information System (INIS)

    Bottiglioni, F.; Coutant, J.; Fois, M.

    1978-01-01

    Areas of possible applications of cluster injection are discussed. The deposition inside the plasma of molecules, issued from the dissociation of the injected clusters, has been computed. Some empirical scaling laws for the penetration are given

  1. Antigen injection (image)

    Science.gov (United States)

    Leprosy is caused by the organism Mycobacterium leprae . The leprosy test involves injection of an antigen just under ... if your body has a current or recent leprosy infection. The injection site is labeled and examined ...

  2. Lateral Parabrachial Nucleus Serotonergic Mechanisms and Salt Appetite Induced by Sodium Depletion

    Science.gov (United States)

    Menani, Jose Vanderlei; DeLuca, Laurival Antonio, Jr.; Johnson, Alan Kim

    1998-01-01

    This study investigated the effects of bilateral injections of a serotonin (5-HT) receptor agonist into the lateral parabrachial nucleus on the intake of NaCl and water induced by 24-h water deprivation or by sodium depletion followed by 24 h of sodium deprivation (injection of the diuretic furosemide plus 24 h of d sodium-deficient diet). Rats had stainless steel cannulas implanted bilaterally into the LPBN. Bilateral LPBN injections of the serotonergic 5-HT(1/2) receptor antagonist methysergide (4 micro-g/200 nl at each site) increased hypertonic NaCl intake when tested 24 h after sodium depletion and after 24 h of water deprivation. Water intake also increased after bilateral injections of methysergide into the LPBN. In contrast, the intake of a palatable solution (0.06 M sucrose) under body fluid-replete conditions was not changed after bilateral LPBN methysergide injections. The results show that serotonergic mechanisms in the LPBN modulate water and sodium intake induced by volume depletion and sodium loss. The finding that sucrose intake was not affected by LPBN serotonergic blockade suggests that the effects of the methysergide treatment on the intakes of water and NaCl are not due to a mechanism producing a nonspecific enhancement of all ingestive behaviors.

  3. Sodium fire tests for investigating the sodium leak in Monju

    International Nuclear Information System (INIS)

    Seino, Hiroshi; Miyahara, Shinya; Miyake, Osamu; Tanabe, Hiromi

    1996-01-01

    As a part of the work for investigating the sodium leak accident which occurred in Monju on December 8, 1995, three tests, (1) sodium leak test, (2) sodium fire test-I, and (3) sodium fire test-II, were carried out at OEC/PNC. Main objectives of these tests are to confirm leak and burning behavior of sodium from the damaged thermometer, and effects of the sodium fire on integrity of the surrounding structure, etc. The main conclusions obtained from the tests are shown as below. 1) Average sodium leak rate obtained from the sodium leak test was about 50 g/sec. This was equivalent to the value estimated from level change in the sodium overflow tank in the Monju accident. 2) Observation from video cameras in the sodium fire tests revealed that in early stages of sodium leak, sodium dropped down out of the flexible tube of thermometer in drips. This dripping and burning were expanded in range as sodium splashed on the duct. 3) Though, in the sodium fire test-I, there was a decrease of about 1 mm at a thickness of the burning pan in the vicinity in just under in the leak point, there were completely no crack and failure. In the meantime, in the sodium fire test-II the six open holes were found in the floor liner. By this liner failure, the reaction between sodium and concrete might take place. At present, while the detailed evaluation on the sodium fire test-II has been mainly carried out, the investigation for clarifying the cause of the liner failure has been also carried out. (author)

  4. Method of preventing sodium from flowing when pipes of a fast breeder reactor are injured

    International Nuclear Information System (INIS)

    Nakai, Yasushi; Yamagishi, Yoshiaki; Koga, Tomonari.

    1975-01-01

    Object: To inject high pressure sodium into an inlet nozzle portion when fluid pressure in the inlet nozzle portion of a core cooling pipe on the inlet side is in an abnormal condition, to thereby quickly and positively prevent the flow of sodium in a high pressure chamber in a reactor vessel, when pipes are injured. Structure: When the core cooling pipe on the inlet side is injured and as a consequence the pressure gage detects an abnormal condition of fluid pressure in the inlet nozzle, the valve is opened to allow high pressure sodium to inject into the inlet nozzle through a high pressure sodium supply pipe, thereby blocking a back-flow of sodium in the high pressure chamber into the core cooling pipe. (Kamimura, M.)

  5. The combustion of sodium

    International Nuclear Information System (INIS)

    Newman, R.N.

    1978-01-01

    The burning rates of sodium in the form of vapour jets, droplets, sprays and unconfined and confined pools have been reviewed. Attention has been paid to assessing the value of models in the various combustion modes. Additional models have been constructed for the descriptions of laminar and turbulent vapour jets, stationary droplets, forced convection over ambient pool fires together with correlations for peak pressures in confined pool environments. Where appropriate experiments with sodium have not been conducted, the likely behaviour is predicted by comparison with the burning of other fuels, particularly in the field of large free ambient fires. Some areas where further knowledge is required are highlighted. (author)

  6. Too Much Sodium

    Centers for Disease Control (CDC) Podcasts

    2012-02-07

    This podcast is based on the February 2012 CDC Vital Signs report. Ninety percent of Americans age two and older eat too much sodium which can increase your risk for high blood pressure and often leads to heart disease and stroke, two leading causes of death in the US. Learn several small steps you can take to reduce the amount of sodium in your diet.  Created: 2/7/2012 by Centers for Disease Control and Prevention (CDC).   Date Released: 2/7/2012.

  7. Sodium fluxes in sweet pepper exposed to varying sodium concentrations

    NARCIS (Netherlands)

    Blom-Zandstra, M.; Vogelzang, S.A.; Veen, B.W.

    1998-01-01

    The sodium transport and distribution of sweet pepper (Capsicum annuum L.) under saline conditions were studied after transferring the plants to a sodium-free nutrient solution. Sodium stress up to 60 mM did not affect the growth of sweet pepper, as it appears able to counteract the unfavourable

  8. Sodium hydride precipitation in sodium cold traps

    International Nuclear Information System (INIS)

    McPheeters, C.C.; Raue, D.J.

    1979-10-01

    A series of experiments have been performed to test a calculational model for precipitation of NaH in sodium cold traps. The calculational model, called ACTMODEL, is a computer simulation that uses the system geometry and operating conditions as input to calculate a mass transfer coefficient and the distribution of NaH in a cold trap. The ACTMODEL was tested using an analytical cold trap (ACT) that is simple and essentially one-dimensional. The ACT flow and temperature profile may be controlled at any desired condition. The ACT was analyzed destructively after each test to measure the actual NaH distribution. Excellent agreement was obtained between the ACTMODEL simulations and the experiments

  9. Sodium hydride precipitation in sodium cold traps

    International Nuclear Information System (INIS)

    McPheeters, C.C.; Raue, D.J.

    1980-06-01

    A series of experiments have been performed to test a calculational model for precipitation of NaH in sodium cold traps. The calculational model, called ACTMODEL, is a computer simulation that uses the system geometry and operating conditions as input to calculate a mass-transfer coefficient and the distribution of NaH in a cold trap. The ACTMODEL was tested using an analytical cold trap (ACT) that is simple and essentially one-dimensional. The ACT flow and temperature profile can be controlled at any desired condition. The ACT was analyzed destructively after each test to measure the actual NaH distribution. Excellent agreement was obtained between the ACTMODEL simulations and the experiments. Mass-transfer coefficients ranging upward from 6 x 10 -5 m/s were measured in both packless and packed traps. As much as a fourfold increase in precipitation surface area was observed with increasing amount of NaH deposited. 11 figures, 2 tables

  10. Thermophysical properties of sodium

    International Nuclear Information System (INIS)

    Harant, M.

    1978-01-01

    Substitution, inverse and substitution inverse relations in form of regression polynomials were used in calculating saturation pressure and density for thermodynamic and transport properties determination of sodium. Program UNISOAUT/A3 was used in calculating regression polynomials coefficients. (J.P.)

  11. Extinction of sodium fires

    International Nuclear Information System (INIS)

    Malet, J.C.; Spagna, F.

    1989-01-01

    This paper presents how, starting from a knowledge of sodium ignition and burning, principles for extinction (smothering catch trays, leak recuperation systems, powders) can be developed. These techniques applied in Superphenix 1 and PEC reactors have been tested in the ESMERALDA experimental program which is a joint French/Italian project. (author)

  12. Decomposition of Sodium Tetraphenylborate

    International Nuclear Information System (INIS)

    Barnes, M.J.

    1998-01-01

    The chemical decomposition of aqueous alkaline solutions of sodium tetraphenylborate (NaTPB) has been investigated. The focus of the investigation is on the determination of additives and/or variables which influence NaTBP decomposition. This document describes work aimed at providing better understanding into the relationship of copper (II), solution temperature, and solution pH to NaTPB stability

  13. Sodium purification in Rapsodie

    International Nuclear Information System (INIS)

    Giraud, B.

    1968-01-01

    This report is one of a series of publications presenting the main results of tests carried out during the start-up of the first french fast neutron reactor: Rapsodie. The article presents the sodium purification techniques used in the reactor cooling circuits both from the constructional point of view and with respect to results obtained during the first years working. (author) [fr

  14. The medical sodium chloride

    International Nuclear Information System (INIS)

    Mirsaidov, U.M.

    2002-01-01

    In the institute was investigated the chemical composition of rock salt of some deposits of Tajikistan and was show the presence in it admixture of ions of Ca 2 + , Mg 2 + a nd SO 2 - a nd absence of heavy metals, ammonium salts, iron, potassium and arsenic. Was elaborated the fundamental instrument-technologic scheme of sodium chloride receiving

  15. Creep in sodium

    International Nuclear Information System (INIS)

    Charnock, W.; Cordwell, J.E.

    1978-03-01

    Available information on the creep of austenitic, ferritic and Alloy-800 type steels in liquid sodium is critically reviewed. Creep properties of stainless steels can be affected by element transfer and corrosion. At reactor structural component temperatures environmental effects are likely to be less important than changes due to thermal ageing. At high clad temperatures (700 0 C) decarburisation may cause the loss of strength and ductility in unstabilised steels while cavity formation may cause embrittlement in stabilised steels. The properties of Alloy 800 are, in some experiments, found to deteriorate while in others they are enhanced. This may be a consequence of the metallurgical complexity of the material or arise from the nature of the various techniques employed. Low alloy ferritic steels tend to decarburise in sodium at temperatures greater than 500 0 C and this leads to loss of strength and an increase in ductility. High alloy ferritics are immune to this effect and appear to be able to tolerate a degree of carburisation. Although intergranular cracking may be enhanced in liquid sodium the mechanical consequences are not significant and evidence for the existence of an embrittlement effect not associated with element transfer or corrosion is weak. Stress and strain may enhance element transfer at crack tips. However in real cracks the gettering or supply action of the crack faces conditions the chemistry of the cracks in sodium and protects the crack tip from element transfer. Thus creep crack extension rates should be independent of changes in bulk coolant chemistry. (author)

  16. Technology for sodium purity control

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Ji Young; Kim, B. H.; Kim, T. J. [Korea Atomic Energy Research Institute, Taejon (Korea)

    1999-10-01

    When sodium is used as heat transfer fluid, the plugging in coolant flow, the corrosion of structure material and the transfer of radioactive material caused by the impurities in sodium are worth considerable. Accordingly, these impurities must be monitored and controlled continuously by sodium purification devices in the heat transfer system which sodium is used as coolant. Sodium purification loop was constructed for the purpose of accumulating the technology for purity control of the coolant, developing and verifying further efficient instruments for sodium purification. The plugging meter and the cold trap is used as the implement for measuring and controlling the oxygen and the hydrogen, the main impurities in sodium coolant. They are capable of excellent performance as the implements which could detect and monitor the impurities to the concentration limit required for nuclear reactor. Sodium purification loop could be used variably according to the experimental purpose. 18 refs., 34 figs., 8 tabs. (Author)

  17. Persulfate injection into a gasoline source zone.

    Science.gov (United States)

    Sra, Kanwartej S; Thomson, Neil R; Barker, Jim F

    2013-07-01

    One pore volume of unactivated sodium persulfate was delivered into an emplaced gasoline residual source zone at CFB Borden. Concentrations of inorganic species (S2O8(2-), SO4(2-), Na(+), dissolved inorganic carbon (DIC)) and selected gasoline compounds (benzene, toluene, ethylbenzene, xylenes, trimethylbenzenes and naphthalene) were monitored across a transect equipped with 90 multilevel sampling points for >10months post-injection. Mass loading (M˙) of compounds constructed from the transect data was used for assessment purposes. Breakthrough of inorganic species was observed when the injection slug crossed the monitoring transect. An increase in [Formula: see text] indicated persulfate consumption during oxidation of gasoline compounds or degradation due to the interaction with aquifer materials. M˙DIC increased by >100% suggesting some mineralization of gasoline compounds during treatment. Mass loading for all the monitored gasoline compounds reduced by 46 to 86% as the inorganic slug crossed the monitoring transect. The cumulative mass discharge across the monitoring transect was 19 to 58% lower than that expected without persulfate injection. After the inorganic injection slug was flushed from the source zone a partial rebound (40 to 80% of baseline levels) of mass discharge of the monitored gasoline compounds was observed. The ensemble of data collected provides insight into the fate and transport of the injected persulfate solution, and the accompanying treatment of a gasoline the source zone. Copyright © 2013 Elsevier B.V. All rights reserved.

  18. Persulfate injection into a gasoline source zone

    Science.gov (United States)

    Sra, Kanwartej S.; Thomson, Neil R.; Barker, Jim F.

    2013-07-01

    One pore volume of unactivated sodium persulfate was delivered into an emplaced gasoline residual source zone at CFB Borden. Concentrations of inorganic species (S2O82 -, SO42 -, Na+, dissolved inorganic carbon (DIC)) and selected gasoline compounds (benzene, toluene, ethylbenzene, xylenes, trimethylbenzenes and naphthalene) were monitored across a transect equipped with 90 multilevel sampling points for > 10 months post-injection. Mass loading (M˙) of compounds constructed from the transect data was used for assessment purposes. Breakthrough of inorganic species was observed when the injection slug crossed the monitoring transect. An increase in M indicated persulfate consumption during oxidation of gasoline compounds or degradation due to the interaction with aquifer materials. M increased by > 100% suggesting some mineralization of gasoline compounds during treatment. Mass loading for all the monitored gasoline compounds reduced by 46 to 86% as the inorganic slug crossed the monitoring transect. The cumulative mass discharge across the monitoring transect was 19 to 58% lower than that expected without persulfate injection. After the inorganic injection slug was flushed from the source zone a partial rebound (40 to 80% of baseline levels) of mass discharge of the monitored gasoline compounds was observed. The ensemble of data collected provides insight into the fate and transport of the injected persulfate solution, and the accompanying treatment of a gasoline the source zone.

  19. Sulfate Reduction Remediation of a Metals Plume Through Organic Injection

    International Nuclear Information System (INIS)

    Phifer, M.A.

    2003-01-01

    Laboratory testing and a field-scale demonstration for the sulfate reduction remediation of an acidic/metals/sulfate groundwater plume at the Savannah River Site has been conducted. The laboratory testing consisted of the use of anaerobic microcosms to test the viability of three organic substrates to promote microbially mediated sulfate reduction. Based upon the laboratory testing, soybean oil and sodium lactate were selected for injection during the subsequent field-scale demonstration. The field-scale demonstration is currently ongoing. Approximately 825 gallons (3,123 L) of soybean oil and 225 gallons (852 L) of 60 percent sodium lactate have been injected into an existing well system within the plume. Since the injections, sulfate concentrations in the injection zone have significantly decreased, sulfate-reducing bacteria concentrations have significantly increased, the pH has increased, the Eh has decreased, and the concentrations of many metals have decreased. Microbially mediated sulfate reduction has been successfully promoted for the remediation of the acidic/metals/sulfate plume by the injection of soybean oil and sodium lactate within the plume

  20. Slicing sodium from bakery products

    NARCIS (Netherlands)

    Noort, M.

    2012-01-01

    The need for sodium reduction in our diet is clear to consumers, dieticians and food manufacturers. As sodium concentration has a strengthening effect on gluten, sodium reduction decreases dough mixing tolerance, dough resistance and induces dough stickiness. In particular, the latter may cause

  1. Safety measuring for sodium handling

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Ji Young; Jeong, K C; Kim, T J; Kim, B H; Choi, J H

    2001-09-01

    This is the report for the safety measures of sodium handling. These contents are prerequisites for the development of sodium technology and thus the workers participate in sodium handling and experiments have to know them perfectly. As an appendix, the relating parts of the laws are presented.

  2. Specialists' meeting on sodium fires

    Energy Technology Data Exchange (ETDEWEB)

    Kozlov, F A; Kuznetsova, R I [eds.

    1989-07-01

    The four sessions of the meeting covered the following topics: 1. general approach to fast reactor safety, standards of fire safety, maximum design basis accidents for sodium leaks and fires, status of sodium fires in different countries; 2. physical and chemical processes during combustion of sodium and its interaction with structural and technological materials and methods for structural protection; 3. methods of sodium fires extinguishing and measures for localizing aerosol combustion products, organization of fire fighting procedures, instruction and training of fire personnel; 4. elimination of the consequences of sodium fires.

  3. Specialists' meeting on sodium fires

    International Nuclear Information System (INIS)

    Kozlov, F.A.; Kuznetsova, R.I.

    1989-01-01

    The four sessions of the meeting covered the following topics: 1. general approach to fast reactor safety, standards of fire safety, maximum design basis accidents for sodium leaks and fires, status of sodium fires in different countries; 2. physical and chemical processes during combustion of sodium and its interaction with structural and technological materials and methods for structural protection; 3. methods of sodium fires extinguishing and measures for localizing aerosol combustion products, organization of fire fighting procedures, instruction and training of fire personnel; 4. elimination of the consequences of sodium fires

  4. SQL injection detection system

    OpenAIRE

    Vargonas, Vytautas

    2017-01-01

    SQL injection detection system Programmers do not always ensure security of developed systems. That is why it is important to look for solutions outside being reliant on developers. In this work SQL injection detection system is proposed. The system analyzes HTTP request parameters and detects intrusions. It is based on unsupervised machine learning. Trained by regular request data system detects outlier user parameters. Since training is not reliant on previous knowledge of SQL injections, t...

  5. Development of Sodium Technology

    International Nuclear Information System (INIS)

    Choi, Jong Hyun; Nam, H. Y.; Kim, T. J.; Jeong, K. C.; Park, J. H.; Kim, B. H.; Jeong, J. Y.; Kim, J. M.; Choi, B. H.; Kim, B. S.

    2003-02-01

    The basic P and ID and fabrication method for IHTS simplification experiment were prepared for the experimental apparatus. In order to investigate the later phase of a SWR event, an experimental apparatus was designed and manufactured. The 620 data set have been obtained in the experiment of free surface fluctuation and an experimental correlation for the critical gas entertainment condition is additionally developed. For development of water into sodium leak detection technology, the properties from leak noises were extracted, and the tools for analyzing acoustic noises were constructed. The state-of-the-art on the flow and differential pressure measuring techniques in the piping system is investigated to develop new techniques which are applicable to high temperature sodium flow environment. The plan for the minimization of errors in temperature measurement was drawn up by analysing the error factors in temperature measurement. And the countermeasures for the minimization of errors in temperature measurement due to complex heat transfer were prepared

  6. Sodium conducting polymer electrolytes

    Energy Technology Data Exchange (ETDEWEB)

    Skaarup, S.; West, K. (eds.)

    1989-04-01

    This section deals with the aspects of ionic conduction in general as well as specific experimental results obtained for sodium systems. The conductivity as a function of temperature and oxygen/metal ratio are given for the systems NaI, NaCF/sub 3/SO/sub 3/ and NaClO/sub 4/ plus polyethylene oxide. Attempts have been made to produce mixed phase solid electrolytes analogous to the lithium systems that have worked well. These consist of mixtures of polymer and a solid electrolyte. The addition of both nasicon and sodium beta alumina unexpectedly decreases the ionic conductivity in contrast to the lithium systems. Addition of the nonconducting silica AEROSIL in order to increase the internal surface area has the effect of retarding the phase transition at 60 deg. C, but does not enhance the conductivity. (author) 23 refs.

  7. Piezoelectric Injection Systems

    Science.gov (United States)

    Mock, R.; Lubitz, K.

    The origin of direct injection can be doubtlessly attributed to Rudolf Diesel who used air assisted injection for fuel atomisation in his first self-ignition engine. Although it became apparent already at that time that direct injection leads to reduced specific fuel consumption compared to other methods of fuel injection, it was not used in passenger cars for the moment because of its disadvantageous noise generation as the requirements with regard to comfort were seen as more important than a reduced specific consumption.

  8. Urinary incontinence - injectable implant

    Science.gov (United States)

    ... repair; ISD repair; Injectable bulking agents for stress urinary incontinence ... and disorders: physiology of micturition, voiding dysfunction, urinary incontinence, urinary tract infections, and painful bladder syndrome. In: Lobo ...

  9. Experimental study on combustion characteristics of sodium fire in a columnar flow

    International Nuclear Information System (INIS)

    Zhang Zhigang; Peng Kangwei; Guo Ming; Huo Yan

    2014-01-01

    In the operation of the sodium-cooled fast reactor, the accident caused by the leakage and combustion of liquid sodium is common and frequent in sodium-related facilities. This paper is based on an experimental study of sodium fire in a columnar flow, which was carried out to focus on the burning characteristics by analyzing the temperature fields in the burner. The injection of 200°C liquid sodium with the flux of 0.5 m 3 /h was poured into a 7.9 m 3 volume stainless steel cylindrical burner to shape a sodium fire, and the data of temperature fields in the burner have been collected by dozens of thermocouples which are laid in the combustion space and sodium collection plate. These results show that the sodium fire in a columnar flow is composed of the foregoing centered columnar fire, the subsequent spray fire caused by atomization and the pool fire on the collection plate. The temperature close to the burning sodium flow maximally reaches up to 950°C. The radial temperatures apart from the sodium flow are relatively low and generally about 200°C, and maximally just 300°C even when close to the sodium collection plate. The maximum temperature of the burning sodium dropping on the collection plate rises in the center of plate, about 528°C. This study is helpful to evaluate the combustion characteristics, formation process and composing forms of the sodium fire in the sodium-related facilities. (author)

  10. Is it safe to re-access sodium bicarbonate bottles for use in minor surgery?

    Science.gov (United States)

    Bjornson, Lindsay; Bucevska, Marija; Tilley, Peter; Verchere, Cynthia

    2018-04-06

    Sodium bicarbonate is added to lidocaine to reduce injection pain. In Canada, it is available in vials exceeding the injection volume 100-fold. These are single-use vials that should be disposed of after one access. Some surgeons re-use vials to reduce waste, potentially causing contamination. This study aims to review the safety of sodium bicarbonate and assess alternatives to current practice. Strains of Staphylococcus aureus, Staphylococcus epidermidis, Pseudomonas aeruginosa, and Burkholderia cepacia were used to assess bacterial growth in vials of sodium bicarbonate. Each pathogen was inoculated into a vial for 14 days at room temperature. At several time points, 1 mL of solution was removed and diluted. One hundred microliters were transferred to blood agar plates and incubated at 35 °C. Colony counts were calculated, averaged and plotted onto a logarithmic graph. Colony counts of all strains fell below observational threshold after 7 days in sodium bicarbonate. Although all strains were reduced, bacteria can survive in sodium bicarbonate for several days, during which transmission may occur. Sodium bicarbonate vials should be treated as single-dose, as indicated by the manufacturers. To reduce waste, hospital pharmacies can repackage sodium bicarbonate into smaller vials or pre-alkalize lidocaine with sodium bicarbonate. Copyright © 2018 Elsevier Inc. All rights reserved.

  11. Electron injection in microtron

    International Nuclear Information System (INIS)

    Axinescu, S.

    1977-01-01

    A review of the methods of injecting electrons in the microtron is presented. A special attention is paid to efficient injection systems developed by Wernholm and Kapitza. A comparison of advantages and disadvantages of both systems is made in relation to the purpose of the microtron. (author)

  12. Glenohumeral Joint Injections

    Science.gov (United States)

    Gross, Christopher; Dhawan, Aman; Harwood, Daniel; Gochanour, Eric; Romeo, Anthony

    2013-01-01

    Context: Intra-articular injections into the glenohumeral joint are commonly performed by musculoskeletal providers, including orthopaedic surgeons, family medicine physicians, rheumatologists, and physician assistants. Despite their frequent use, there is little guidance for injectable treatments to the glenohumeral joint for conditions such as osteoarthritis, adhesive capsulitis, and rheumatoid arthritis. Evidence Acquisition: We performed a comprehensive review of the available literature on glenohumeral injections to help clarify the current evidence-based practice and identify deficits in our understanding. We searched MEDLINE (1948 to December 2011 [week 1]) and EMBASE (1980 to 2011 [week 49]) using various permutations of intra-articular injections AND (corticosteroid OR hyaluronic acid) and (adhesive capsulitis OR arthritis). Results: We identified 1 and 7 studies that investigated intra-articular corticosteroid injections for the treatment of osteoarthritis and adhesive capsulitis, respectively. Two and 3 studies investigated the use of hyaluronic acid in osteoarthritis and adhesive capsulitis, respectively. One study compared corticosteroids and hyaluronic acid injections in the treatment of osteoarthritis, and another discussed adhesive capsulitis. Conclusion: Based on existing studies and their level of evidence, there is only expert opinion to guide corticosteroid injection for osteoarthritis as well as hyaluronic acid injection for osteoarthritis and adhesive capsulitis. PMID:24427384

  13. Dimethyl Ether Injection Studies

    DEFF Research Database (Denmark)

    Sorenson, Spencer C.; Glensvig, Michael; Abata, Duane L.

    1998-01-01

    A series of preliminary investigations has been performed in order to investigate the behavior of DME in a diesel injection environment. These studies have in-cluded visual observations of the spray penetration and angles for high pressure injection into Nitrogen using conventional jerk pump inje...

  14. Sodium characterization during the starting period of a sodium loop

    International Nuclear Information System (INIS)

    Lievens, F.; Parmentier, C.; Soenen, M.

    1976-01-01

    A sodium loop for analytical chemistry studies has been built by S.C.K./C.E.N. at Mol Belgium. Its first working period was used to test analytical methods, to characterize the sodium and to define the operating parameters of the loop. This report covers the working parameters of the loop, the characterization of the filling sodium and its purity evolution during the first working period of the loop

  15. Viscous hydrophilic injection matrices for serial crystallography

    Directory of Open Access Journals (Sweden)

    Gabriela Kovácsová

    2017-07-01

    Full Text Available Serial (femtosecond crystallography at synchrotron and X-ray free-electron laser (XFEL sources distributes the absorbed radiation dose over all crystals used for data collection and therefore allows measurement of radiation damage prone systems, including the use of microcrystals for room-temperature measurements. Serial crystallography relies on fast and efficient exchange of crystals upon X-ray exposure, which can be achieved using a variety of methods, including various injection techniques. The latter vary significantly in their flow rates – gas dynamic virtual nozzle based injectors provide very thin fast-flowing jets, whereas high-viscosity extrusion injectors produce much thicker streams with flow rates two to three orders of magnitude lower. High-viscosity extrusion results in much lower sample consumption, as its sample delivery speed is commensurate both with typical XFEL repetition rates and with data acquisition rates at synchrotron sources. An obvious viscous injection medium is lipidic cubic phase (LCP as it is used for in meso membrane protein crystallization. However, LCP has limited compatibility with many crystallization conditions. While a few other viscous media have been described in the literature, there is an ongoing need to identify additional injection media for crystal embedding. Critical attributes are reliable injection properties and a broad chemical compatibility to accommodate samples as heterogeneous and sensitive as protein crystals. Here, the use of two novel hydrogels as viscous injection matrices is described, namely sodium carboxymethyl cellulose and the thermo-reversible block polymer Pluronic F-127. Both are compatible with various crystallization conditions and yield acceptable X-ray background. The stability and velocity of the extruded stream were also analysed and the dependence of the stream velocity on the flow rate was measured. In contrast with previously characterized injection media, both new

  16. Whole body measurements of sodium turnover in offspring of patients with sustained essential hypertension

    International Nuclear Information System (INIS)

    Henningsen, N.C.; Ohlsson, O.; Mattson, S.; Nosslin, B.; Lund Univ.; Lund Univ.

    1982-01-01

    The elimination rate (percent per day) of injected 22 Na using a whole body measurement technique was significantly lower (26%, 5.8 +- 1.5) in normotensive of borderline hypertensive offspring of essential hypertensive patients than in 15 age- and sex-matched, normotensive controls (7.3 +- 1.0). There were no significant differences in exchangeable sodium, whole body potassium or in the urinary exeretion of sodium, potassium and creatinine. The basis for the difference in turnover rate during weck 1 is probably an alteration in the cellular handling of sodium (i.e. increased intracellular sodium) in the still normotensive offspring of patients with essential hypertension. The long-term (more than 100 days) whole body retention of 22 Na was found to be only 0.1% of that injected, which justifies the use of the method on larger population groups. (orig.)

  17. Double sodium rubidium molybdates

    International Nuclear Information System (INIS)

    Mokhoseev, M.V.; Khal'baeva, K.M.; Khajkina, E.G.; Ogurtsov, A.M.

    1990-01-01

    According to ceramic technique double sodium-rubidium molybdates of the compositions Rb 2-x Na x MoO 4 (0.5≤x≤0.67) and Na 3 Rb(MoO 4 ) 2 have been prepared. It is ascertained that Rb 2-x Na x MoO 4 is crystallized in glaserite structural type (trigonal crystal system, sp.gr. P3m1, Z=2) and melts incongruently at 640 deg C. Na 3 Rb(MoO 4 ) 2 at room temperature is unstable and gradually decomposes into Na 2 MoO 4 and Rb 2-x Na x MoO 4

  18. The various sodium purification techniques

    International Nuclear Information System (INIS)

    Courouau, J.L.; Masse, F.; Rodriguez, G.; Latge, C.; Redon, B.

    1997-01-01

    In the framework of sodium waste treatment, the sodium purification phase plays an essential role in the chain of operations leading to the transformation of the active sodium, considered as waste, into a stable sodium salt. The objectives of the purification operations are: To keep a low impurity level, particularly a low concentration in oxygen and hydrogen, in order to allow its transfer to a processing plant, and in order to avoid risks of plugging and/or corrosion in sodium facilities; To reduce the sodium activity in order to limit the dose rate close to the facilities, and in order to reduce the activity of the liquid and gaseous effluents. After a recall of the different kind of impurities that can be present in sodium, and of the different purification methods that could be associated with, the following points are highlighted: (i) Oxygen and hydrogen purification needs, and presentation of some selection criteria for a purification unit adapted to a sodium processing plant, as well as 2 cold trap concepts that are in accordance with these criteria: PSICHOS and PIRAMIDE. (ii) Tritium reduction in a bulk of liquid sodium by swamping, isotopic exchange, or permeation throughout a membrane. (iii) Caesium trapping on carbonaceous matrix. The main matrices used at present are R.V.C. (Reticulated Vitreous Carbon) and Actitex/Pica products. Tests in the laboratory and on an experimental device have demonstrated the performances of these materials, which are able to reduce sodium activity in Cs 134 and Cs 137 to very low values. The sodium purification processes as regards to the hydrogen, oxygen and caesium, that are aimed at facilitating the subsequent treatment of sodium, are therefore mastered operations. Regarding the operations associated with the reduction of the tritium activity, the methods are in the process of being qualified, or to be qualified. (author)

  19. Physical properties of liquid sodium

    International Nuclear Information System (INIS)

    Alberdi Primicia, J.; Martinez Piquer, T.A.

    1977-01-01

    The molten sodium has been the more accepted coolant for the first generation of FBR, by this reason the knowledge of its technology is needed for the development of the next LMFBR. A series of necessary data for designing sodium liquid systems are given. Tables and graphics about the most important physical sodium properties between 1200-1400 degC are gathered. The results have been obtained from equations that relate the properties with temperature using a Fortran IV program. (author) [es

  20. Carbon transport in sodium systems

    International Nuclear Information System (INIS)

    Martin Espigares, M.; Lapena, J.; La Torre, M. de

    1983-01-01

    Carbon activities in dynamic non isothermal sodium system are determined using an equilibratium method. Foils of Fe-18 w% Cr-8 W% Ni alloy with low carbon content (in the as received condition) are exposed to dynamic liquid sodium in the temperature range between 450 0 C and 700 0 C. The analysis was used to evaluate the carburization-decarburization behaviour of type 304 stainless steel exposed to sodium. (author)

  1. THE RHIC INJECTION SYSTEM.

    Energy Technology Data Exchange (ETDEWEB)

    FISCHER,W.; GLENN,J.W.; MACKAY,W.W.; PTITSIN,V.; ROBINSON,T.G.; TSOUPAS,N.

    1999-03-29

    The RHIC injection system has to transport beam from the AGS-to-RHIC transfer line onto the closed orbits of the RHIC Blue and Yellow rings. This task can be divided into three problems. First, the beam has to be injected into either ring. Second, once injected the beam needs to be transported around the ring for one turn. Third, the orbit must be closed and coherent beam oscillations around the closed orbit should be minimized. We describe our solutions for these problems and report on system tests conducted during the RHIC Sextant test performed in 1997. The system will be fully commissioned in 1999.

  2. Injection moulding antireflective nanostructures

    DEFF Research Database (Denmark)

    Christiansen, Alexander Bruun; Clausen, Jeppe Sandvik; Mortensen, N. Asger

    2014-01-01

    We present a method for injection moulding antireflective nanostructures on large areas, for high volume production. Nanostructured black silicon masters were fabricated by mask-less reactive ion etching, and electroplated with nickel. The nickel shim was antistiction coated and used in an inject......We present a method for injection moulding antireflective nanostructures on large areas, for high volume production. Nanostructured black silicon masters were fabricated by mask-less reactive ion etching, and electroplated with nickel. The nickel shim was antistiction coated and used...

  3. Injection moulding antireflective nanostructures

    DEFF Research Database (Denmark)

    Christiansen, Alexander Bruun; Clausen, Jeppe Sandvik; Mortensen, N. Asger

    We present a method for injection moulding antireflective nanostructures on large areas, for high volume production. Nanostructured black silicon masters were fabricated by mask-less reactive ion etching, and electroplated with nickel. The nickel shim was antistiction coated and used in an inject......We present a method for injection moulding antireflective nanostructures on large areas, for high volume production. Nanostructured black silicon masters were fabricated by mask-less reactive ion etching, and electroplated with nickel. The nickel shim was antistiction coated and used...

  4. Modeling of under-expanded reactive CO2-into-sodium jets, in the frame of sodium fast reactors

    International Nuclear Information System (INIS)

    Vivaldi, D.

    2013-01-01

    This PhD work was motivated by the investigations in the frame of supercritical CO 2 Brayton cycles as possible energy conversion cycles for the Sodium-cooled Fast nuclear Reactors (SFRs). This technology represents an alternative to conventional steam Rankine cycles, with the main advantage represented by the elimination of the accidental sodium-water reaction scenario. Nevertheless, CO 2 chemically reacts with sodium, through an exothermic reaction leading to solid reaction products, mainly sodium carbonate. Following an accidental leakage inside the sodium-CO 2 heat exchanger of a SFR, the CO 2 , having an operating pressure of about 200 bars, would be injected into the low-operating pressure liquid sodium, creating an under-expanded reactive CO 2 -into-sodium jet. The under-expanded jet features a sonic gas injection velocity and an under-expansion in the first region downstream the leakage, where the CO 2 is accelerated to supersonic velocities. The exothermic reaction between the CO 2 and the sodium causes an increasing of the temperature inside the heat exchanger. An experimental facility was built at CEA Cadarache, for the realization of CO 2 -into-sodium jets: this facility has provided preliminary results in terms of temperature variations inside the jet due to the exothermic reaction. However, this type of experimental tests are complicated to realize and to analyse, due to the technical difficulties of realizing the contact between CO 2 and sodium, and to the incertitude of temperature measurement inside a two-phase high velocity jet. It follows that a numerical model of this kind of jets is required, in order to understand the CO 2 -sodium kinetics of reaction inside the jet and being able to transpose the phenomenon to relevant SFR sodium-CO 2 heat exchangers. This would allow to understand the consequences of a leakage inside a sodium-CO 2 heat exchanger, in terms of, for instance, temperature profiles inside the heat exchanger and on tube surfaces

  5. Sodium waste technology: A summary report

    International Nuclear Information System (INIS)

    Abrams, C.S.; Witbeck, L.C.

    1987-01-01

    The Sodium Waste Technology (SWT) Program was established to resolve long-standing issues regarding disposal of sodium-bearing waste and equipment. Comprehensive SWT research programs investigated a variety of approaches for either removing sodium from sodium-bearing items, or disposal of items containing sodium residuals. The most successful of these programs was the design, test, and the production operation of the Sodium Process Demonstration Facility at ANL-W. The technology used was a series of melt-drain-evaporate operations to remove nonradioactive sodium from sodium-bearing items and then converting the sodium to storable compounds

  6. Effects of topical flurbiprofen sodium, diclofenac sodium, ketorolac ...

    African Journals Online (AJOL)

    To evaluate corneal sensitivity by using the Cochet-Bonnet® esthesiometer in normal canine eyes at different time points following instillation of three different topical non-steroidal anti-inflammatory drugs (flurbiprofen sodium 0.03%, diclofenac sodium 0.1% and ketorolac tromethamine 0.5%) and benzalkonium chloride ...

  7. A Simple Quantitative Synthesis: Sodium Chloride from Sodium Carbonate.

    Science.gov (United States)

    Gold, Marvin

    1988-01-01

    Describes a simple laboratory procedure for changing sodium carbonate into sodium chloride by adding concentrated HCl to cause the reaction and then evaporating the water. Claims a good stoichiometric yield can be obtained in one three-hour lab period. Suggests using fume hood for the reaction. (ML)

  8. Hip joint injection

    Science.gov (United States)

    ... medicine into the joint. The provider uses a real-time x-ray (fluoroscopy) to see where to place ... Wakefield RJ. Arthrocentesis and injection of joints and soft tissue. In: Firestein GS, Budd RC, Gabriel SE, ...

  9. Premixed direct injection disk

    Science.gov (United States)

    York, William David; Ziminsky, Willy Steve; Johnson, Thomas Edward; Lacy, Benjamin; Zuo, Baifang; Uhm, Jong Ho

    2013-04-23

    A fuel/air mixing disk for use in a fuel/air mixing combustor assembly is provided. The disk includes a first face, a second face, and at least one fuel plenum disposed therebetween. A plurality of fuel/air mixing tubes extend through the pre-mixing disk, each mixing tube including an outer tube wall extending axially along a tube axis and in fluid communication with the at least one fuel plenum. At least a portion of the plurality of fuel/air mixing tubes further includes at least one fuel injection hole have a fuel injection hole diameter extending through said outer tube wall, the fuel injection hole having an injection angle relative to the tube axis. The invention provides good fuel air mixing with low combustion generated NOx and low flow pressure loss translating to a high gas turbine efficiency, that is durable, and resistant to flame holding and flash back.

  10. Imipenem and Cilastatin Injection

    Science.gov (United States)

    Imipenem and cilastatin injection is used to treat certain serious infections that are caused by bacteria, including ... area), gynecological, blood, skin, bone, and joint infections. Imipenem is in a class of medications called carbapenem ...

  11. Quinupristin and Dalfopristin Injection

    Science.gov (United States)

    ... are in a class of medications called streptogramin antibiotics. They work by killing bacteria that cause infections.Antibiotics such as quinupristin and dalfopristin injection will not work for colds, flu, or other viral infections. Taking ...

  12. Botulinum toxin injection - larynx

    Science.gov (United States)

    Injection laryngoplasty; Botox - larynx: spasmodic dysphonia-BTX; Essential voice tremor (EVT)-btx; Glottic insufficiency; Percutaneous electromyography - guided botulinum toxin treatment; Percutaneous indirect laryngoscopy - guided botulinum toxin treatment; ...

  13. The PEP injection system

    International Nuclear Information System (INIS)

    Brown, K.L.; Avery, R.T.; Peterson, J.M.

    1988-01-01

    A system to transport 10-to-15-GeV electron and positron beams from the Stanford Linear Accelerator and to inject them into the PEP storage ring under a wide variety of lattice configurations has been designed. Optically, the transport line consists of three 360/degree/ phase-shift sections of FODO lattice, with bending magnets interspersed in such a way as to provide achromaticity, convenience in energy and emittance definition, and independent tuning of the various optical parameters for matching into the ring. The last 360/degree/ of phase shift has 88 milliradians of bend in a vertical plane and deposits the beam at the injection septum via a Lambertson magnet. Injection is accomplished by launching the beam with several centimeters of radial betatron amplitude in a fast bump provided by a triad of pulsed kicker magnets. Radiation damping reduces the collective amplitude quickly enough to allow injection at a high repetition rate

  14. Sodium-fuel interaction: dropping experiments and subassembly test

    International Nuclear Information System (INIS)

    Holtbecker, H.; Schins, H.; Jorzik, E.; Klein, K.

    1978-01-01

    Nine dropping tests, which bring together 2 to 4 kg of molten UO 2 with 150 l sodium, showed the incoherency and non-violence of these thermal interactions. The pressures can be described by sodium incipient boiling and bubble collapse; the UO 2 fragmentation by thermal stress and bubble collapse impact forces. The mildness of the interaction is principally due to the slowness and incoherency of UO 2 fragmentation. This means that parametric models which assume instantaneous mixing and fragmentation are of no use for the interpretation of dropping experiments. One parametric model, the Caldarola Fuel Coolant Interaction Variable Mass model, is being coupled to the two dimensional time dependent hydrodynamic REXCO-H code. In a first step the coupling is applicated to a monodimensional geometry. A subassembly test is proposed to validate the model. In this test rapid mixing between UO 2 and sodium has to be obtained. Dispersed molten UO 2 fuel is obtained by flashing injected sodium drops inside a UO 2 melt. This flashing is theoretically explained and modelled as a superheat limited explosion. The measured sodium drop dwell times of two experiments are compared to results obtained from the mentioned theory, which is the basis of the Press 2 Code

  15. Injection and Dump Systems

    CERN Document Server

    Bracco, C; Barnes, M J; Carlier, E; Drosdal, L N; Goddard, B; Kain, V; Meddahi, M; Mertens, V; Uythoven, J

    2012-01-01

    Performance and failures of the LHC injection and ex- traction systems are presented. In particular, a comparison with the 2010 run, lessons learnt during operation with high intensity beams and foreseen upgrades are described. UFOs, vacuum and impedance problems related to the injection and extraction equipment are analysed together with possible improvements and solutions. New implemented features, diagnostics, critical issues of XPOC and IQC applications are addressed.

  16. Cavitation erosion in sodium flow, sodium cavitation tunnel testing

    International Nuclear Information System (INIS)

    Courbiere, Pierre.

    1981-04-01

    The high-volume sodium flows present in fast neutron reactors are liable to induce cavitation phenomena in various portion of the sodium lines and pumps. The absence of sufficient data in this area led the C.E.A. to undertake an erosion research program in cavitating sodium flow. This paper discusses the considerations leading to the definition and execution of sodium cavitation erosion tests, and reviews the tests run with 400 0 C sodium on various steel grades: 316, 316 L, 316 Ti (Z8CNDT17-12), Poral (Z3CND18-12), 304 L and LN2 - clad 316 L (Ni coating-clad 316 L). Acoustic detection and signal processing methods were used with an instrument package designed and implemented at the Cadarache Nuclear Research Center

  17. The experimental sodium facility NAVA

    International Nuclear Information System (INIS)

    Langenbrunner, H.; Grunwald, G.; May, R.

    1976-01-01

    Within the framework of preparations for the introduction of sodium cooled fast breeder reactors an experimental sodium facility was installed at the Central Institute of Nuclear Research at Rossendorf. Design, engineering aspects and operation of this facility are described; operating experience is briefly discussed. (author)

  18. Sodium as a reactor coolant

    International Nuclear Information System (INIS)

    Cesar, S.B.G.

    1989-01-01

    This work is related to the use of sodium as a reactor coolant, to the advantages and problems related to its use, its mechanical, thermophysics, eletronical, magnetic and nuclear properties. It is mainly a bibliographic review, with the aim of gathering the necessary information to persons initiating in the study of sodium and also as reference source. (author) [pt

  19. Recent progress in sodium technology

    Energy Technology Data Exchange (ETDEWEB)

    Hallett, W. J.

    1963-10-15

    Progress over the past year in U. S. laboratories studying some of the materials and engineering problems that must be resolved in bringing the technology of sodium to an economically and technically attractive point is reviewed. The status of sodium cooled power reactors in the U. S. is described. (P.C.H.)

  20. Method of processing waste sodium

    International Nuclear Information System (INIS)

    Shimoyashiki, Shigehiro; Takahashi, Kazuo.

    1982-01-01

    Purpose: To enable safety store of waste sodium in the form of intermetallic compounds. Method: Waste sodium used in a reactor is mixed with molten metal under an inert gas atmosphere and resulted intermetallic compounds are stored in a closely sealed container to enable quasi-permanent safety store as inert compound. Used waste sodium particularly, waste sodium in the primary system containing radioactive substances is charged in a waste sodium melting tank having a heater on the side, the tank is evacuated by a vacuum pump and then sealed with gaseous argon supplied from a gaseous argon tank, and waste sodium is melted under heating. The temperature and the amount of the liquid are measured by a thermometer and a level meter respectively. While on the other hand, molten metal such as Sn, Pb and Zn having melting point above 300 0 C are charged in a metal melting tank and heated by a heater. The molten sodium and the molten metals are charged into a mixing tank and agitated to mix by an induction type agitator. Sodium vapors in the tank are collected by traps. The air in the tank is replaced with gaseous argon. The molten mixture is closely sealed in a drum can and cooled to solidify for safety storage. (Seki, T.)

  1. Techniques for extinguishing sodium fires

    International Nuclear Information System (INIS)

    Raju, Chander; Kale, R.D.

    1979-02-01

    The experimental work done to evaluate the performance of commercially available fire extinguishants and powders for sodium fires is described. Dry chemical powder with sodium bicarbonate base was found very effective. Another effective method of extinghishing fire by using perforated covered tray is also discussed. (auth.)

  2. Friction and wear in sodium

    International Nuclear Information System (INIS)

    Hoffman, N.J.; Droher, J.J.

    1973-01-01

    In the design of a safe and reliable sodium-cooled reactor one of the more important problem areas is that of friction and wear of components immersed in liquid sodium or exposed to sodium vapor. Sodium coolant at elevated temperatures may severely affect most oxide-bearing surface layers which provide corrosion resistance and, to some extent, lubrication and surface hardness. Consequently, accelerated deterioration may be experienced on engaged-motion contact surfaces, which could result in unexpected reactor shutdown from component malfunction or failure due to galling and seizure. An overall view of the friction and wear phenomena encountered during oscillatory rubbing of surfaces in high-temperature, liquid-sodium environments is presented. Specific data generated at the Liquid Metal Engineering Center (LMEC) on this subject is also presented. (U.S.)

  3. Sodium sampling and impurities determination

    International Nuclear Information System (INIS)

    Docekal, J.; Kovar, C.; Stuchlik, S.

    1980-01-01

    Samples may be obtained from tubes in-built in the sodium facility and further processed or they are taken into crucibles, stored and processed later. Another sampling method is a method involving vacuum distillation of sodium, thus concentrating impurities. Oxygen is determined by malgamation, distillation or vanadium balance methods. Hydrogen is determined by the metal diaphragm extraction, direct extraction or amalgamation methods. Carbon is determined using dry techniques involving burning a sodium sample at 1100 degC or using wet techniques by dissolving the sample with an acid. Trace amounts of metal impurities are determined after dissolving sodium in ethanol. The trace metals are concentrated and sodium excess is removed. (M.S.)

  4. Toxicology of plutonium-sodium

    International Nuclear Information System (INIS)

    Hackett, P.L.

    1982-01-01

    Scenarios for liquid-metal fast breeder reactor (LMFBR) accidents predict the loss of sodium coolant, with subsequent core melt-down and release of mixed sodium-fuel aerosols [Na-(PuU)O 2 ] into the environment. Studies in other laboratories demonstrated that mixed aerosols of Na 2 O-PuO 2 were more readily transported from the lung than PuO 2 aerosols. We therefore devised a continuous aerosol-generating system for animal exposures in which laser-generated fuel aerosols were swept through sodium vapor to form sodium-fuel aerosols. These fuel and sodium-fuel aerosols were compared with regard to their physicochemical properties and their biological behavior following inhalation studies in rats and dogs

  5. Leak detector of liquid sodium

    International Nuclear Information System (INIS)

    Himeno, Yoshiaki.

    1975-01-01

    Object: To arrange a cable core connected to a leakage current detector on the outer wall of piping for liquid sodium, devices or the like and apply a voltage to said core and outer wall to quickly and securely detect the leakage of liquid sodium. Structure: A cable, which is composed of metal coating formed of metal material (copper, steel, stainless, etc.) which is apt to be corroded by reaction products of liquid sodium with water and oxygen in air, and metal oxide (such as magnesium oxide, beryllium oxide, aluminum oxide) as an electric insulator is arranged on the outer wall of pipes or devices. In the event sodium is leaked from the pipes or devices, said metal coating and the insulator are corroded, and the leakage of sodium is sensed by a leakage current detector through the core in the cable. (Kamimura, M.)

  6. Sodium ionization detector and sensor

    International Nuclear Information System (INIS)

    Hrizo, J.; Bauerle, J.E.

    1979-01-01

    Work conducted on a basic technology development effort with the Westinghouse Sodium Ionization Detector (SID) sensor is reported. Included are results obtained for three task areas: (1) On-line operational response testing - in-situ calibration techniques; (2) Performance-reliability characteristics of aged filaments; and (3) Evaluation of chemical interference effects. The results showed that a calibrator filament coated with a sodium compound, when activated, does supply the necessary sodium atoms to provide a valid operational in-situ test. The life time of new Cr 2 0 3 -protected SID sensor filaments can be extended by operating at a reduced temperature. However, there also is a reduction in the sensitivity. Non-sodium species, such as products from a smoldering fire and organic aerosols, produce an interference response from the sensor comparable to a typical sodium response

  7. Targeting sodium channels in cardiac arrhythmia

    NARCIS (Netherlands)

    Remme, Carol Ann; Wilde, Arthur A. M.

    2014-01-01

    Cardiac voltage-gated sodium channels are responsible for proper electrical conduction in the heart. During acquired pathological conditions and inherited sodium channelopathies, altered sodium channel function causes conduction disturbances and ventricular arrhythmias. Although the clinical,

  8. Synthesis and characterization of sodium alkoxides

    Indian Academy of Sciences (India)

    Unknown

    technique and IR spectroscopy. The elemental ... for maintenance or disposal, need to be cleaned free of sodium for the ... scenario on sodium removal using different alcohols are ... ethoxide and sodium n-propoxide by KBr pellet method.

  9. Evolutionary primacy of sodium bioenergetics

    Directory of Open Access Journals (Sweden)

    Wolf Yuri I

    2008-04-01

    Full Text Available Abstract Background The F- and V-type ATPases are rotary molecular machines that couple translocation of protons or sodium ions across the membrane to the synthesis or hydrolysis of ATP. Both the F-type (found in most bacteria and eukaryotic mitochondria and chloroplasts and V-type (found in archaea, some bacteria, and eukaryotic vacuoles ATPases can translocate either protons or sodium ions. The prevalent proton-dependent ATPases are generally viewed as the primary form of the enzyme whereas the sodium-translocating ATPases of some prokaryotes are usually construed as an exotic adaptation to survival in extreme environments. Results We combine structural and phylogenetic analyses to clarify the evolutionary relation between the proton- and sodium-translocating ATPases. A comparison of the structures of the membrane-embedded oligomeric proteolipid rings of sodium-dependent F- and V-ATPases reveals nearly identical sets of amino acids involved in sodium binding. We show that the sodium-dependent ATPases are scattered among proton-dependent ATPases in both the F- and the V-branches of the phylogenetic tree. Conclusion Barring convergent emergence of the same set of ligands in several lineages, these findings indicate that the use of sodium gradient for ATP synthesis is the ancestral modality of membrane bioenergetics. Thus, a primitive, sodium-impermeable but proton-permeable cell membrane that harboured a set of sodium-transporting enzymes appears to have been the evolutionary predecessor of the more structurally demanding proton-tight membranes. The use of proton as the coupling ion appears to be a later innovation that emerged on several independent occasions. Reviewers This article was reviewed by J. Peter Gogarten, Martijn A. Huynen, and Igor B. Zhulin. For the full reviews, please go to the Reviewers' comments section.

  10. Preliminary Results on a Contact between 4 kg of Molten UO2 and Liquid Sodium

    International Nuclear Information System (INIS)

    Amblard, M.

    1976-01-01

    The CORECT II Experiment consists in simulating the penetration of sodium into an assembly when the fuel is molten. In other words, it is a shock-tube type of experiment with dimensions representative of a full-scale assembly. the experiment consists in dropping a 100 litre column of sodium onto partially molten UO 2 . The following measurements are carried out in transient regime: - sodium velocity in the column; - pressure in the interaction chamber; - pressures at the bottom and at the top of a 5 m tube; - pressure in the argon blanket. The experimental parameters are: - the mass of UO 2 involved (about 4 or 7 kg of 80% molten UO 2 ); - the initial temperature of the sodium (up to 700 deg. C); - the pressure of the residual gas in the interaction chamber during the fall of the sodium; - the dimensions of the interaction chamber and the sodium supply tube; - the form of contact between the UO 2 and the sodium (the sodium may fall on partially liquid and settled UO 2 or on UO 2 pre-dispersed by forced trapping of sodium). To date, 6 tests have been performed. These tests have always resulted in fine fragmentation without any violent interaction. Since no knowledge is available on the change of grain size distribution with time, on the temperature of grain formation, and on the grain movement in the sodium, it is very difficult to interpret these UO 2 -Na tests. We intend to carry out more severe interaction tests on this experimental set-up, by eliminating as much as possible the non-condensable gas which cushions the mechanical impact of the sodium on the UO 2 (tests have shown that by strongly de-pressurizing the liquid UO 2 the fuel could be dispersed by boiling, and this effect should also improve the possibilities of a liquid/liquid contact). - by injecting a little sodium into the UO 2 to facilitate its dispersion in the coolant

  11. Sodium bicarbonate-augmented stress thallium myocardial scintigraphy

    International Nuclear Information System (INIS)

    Sarin, Badal; Chugh, Pradeep Kumar; Kaushal, Dinesh; Soni, Nakse Lal; Sawroop, Kishan; Mondal, Anupam; Bhatnagar, Aseem

    2004-01-01

    It is well known that sodium bicarbonate in pharmacological doses induces transient alkalosis, causing intracellular transport of serum potassium. The aims of this study were (a) to investigate whether, in humans, myocardial thallium-201 uptake can be augmented by pretreatment with a single bolus of sodium bicarbonate at a pharmacological dose, (b) to verify general safety aspects of the intervention and (c) to evaluate the clinical implications of augmentation of 201 Tl uptake, if any. Routine exercise myocardial scintigraphy was performed twice in eight adult volunteers (five normal and three abnormal), once without intervention and the second time (within a week) following intravenous administration of sodium bicarbonate (88 mEq in 50 ml) as a slow bolus 1 h prior to the injection of 201 Tl. Conventional myocardial thallium study was compared with sodium bicarbonate interventional myocardial scintigraphy with respect to myocardial uptake (counts per minute per mCi injected dose), washout patterns in normal and abnormal myocardial segments, and overall clinical interpretation based on planar and single-photon emission tomographic (SPET) images. All patients remained asymptomatic after the intervention. A mean increase of 53% in myocardial uptake of thallium was noted in post-exercise acquisitions after the intervention, confirming uptake of the tracer via the potassium-hydrogen pump and its augmentation by transient alkalosis. The washout pattern remained unchanged. The visual quality of planar and SPET images improved significantly after the intervention. Out of the five abnormal myocardial segments identified in three cases, four showed significant filling-in after the intervention, causing the diagnosis to be upgraded from ''partial scar'' to ''ischaemia'', or from ''ischaemia'' to ''normal''. The overall scan impression changed in two out of three such cases. Sodium bicarbonate augmentation may have significant implications for stress-thallium scintigraphy

  12. Sodium bicarbonate-augmented stress thallium myocardial scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Sarin, Badal; Chugh, Pradeep Kumar; Kaushal, Dinesh; Soni, Nakse Lal; Sawroop, Kishan; Mondal, Anupam; Bhatnagar, Aseem [Department of Nuclear Medicine, Institute of Nuclear Medicine and Allied Sciences, Brig. S. K. Mazumdar Road, 110054, Delhi (India)

    2004-04-01

    It is well known that sodium bicarbonate in pharmacological doses induces transient alkalosis, causing intracellular transport of serum potassium. The aims of this study were (a) to investigate whether, in humans, myocardial thallium-201 uptake can be augmented by pretreatment with a single bolus of sodium bicarbonate at a pharmacological dose, (b) to verify general safety aspects of the intervention and (c) to evaluate the clinical implications of augmentation of {sup 201}Tl uptake, if any. Routine exercise myocardial scintigraphy was performed twice in eight adult volunteers (five normal and three abnormal), once without intervention and the second time (within a week) following intravenous administration of sodium bicarbonate (88 mEq in 50 ml) as a slow bolus 1 h prior to the injection of {sup 201}Tl. Conventional myocardial thallium study was compared with sodium bicarbonate interventional myocardial scintigraphy with respect to myocardial uptake (counts per minute per mCi injected dose), washout patterns in normal and abnormal myocardial segments, and overall clinical interpretation based on planar and single-photon emission tomographic (SPET) images. All patients remained asymptomatic after the intervention. A mean increase of 53% in myocardial uptake of thallium was noted in post-exercise acquisitions after the intervention, confirming uptake of the tracer via the potassium-hydrogen pump and its augmentation by transient alkalosis. The washout pattern remained unchanged. The visual quality of planar and SPET images improved significantly after the intervention. Out of the five abnormal myocardial segments identified in three cases, four showed significant filling-in after the intervention, causing the diagnosis to be upgraded from ''partial scar'' to ''ischaemia'', or from ''ischaemia'' to ''normal''. The overall scan impression changed in two out of three such cases. Sodium

  13. Methods in the treatment of sodium wastes

    International Nuclear Information System (INIS)

    Rodriguez, G.

    1997-01-01

    In the domain of sodium waste processing, we have followed a logical route that has enabled us to propose a global method with respect to sodium wastes. This approach has led to: The choice of only those sodium processes using water; The development of sodium purification methods; The development of methods for cutting metallic wastes soiled by or filled with sodium; The transformation of the resulting sodium hydroxide into ultimate solid wastes for surface storage. (author)

  14. Tables of thermodynamic properties of sodium

    International Nuclear Information System (INIS)

    Fink, J.K.

    1982-06-01

    The thermodynamic properties of saturated sodium, superheated sodium, and subcooled sodium are tabulated as a function of temperature. The temperature ranges are 380 to 2508 K for saturated sodium, 500 to 2500 K for subcooled sodium, and 400 to 1600 K for superheated sodium. Tabulated thermodynamic properties are enthalpy, heat capacity, pressure, entropy, density, instantaneous thermal expansion coefficient, compressibility, and thermal pressure coefficient. Tables are given in SI units and cgs units

  15. Methylprednisolone and its related substances in freeze-dried powders for injections

    OpenAIRE

    LJILJANA SOLOMUN; SVETLANA IBRIĆ; VLATKA VAJS; IVAN VUČKOVIĆ; ZORICA VUJIĆ

    2010-01-01

    In this work, the behavior of the active pharmaceutical substances methylprednisolone (in a form of methylprednisolone sodium succinate) in finished pharmaceutical dosage form, i.e., freeze-dried powder for injections was examined. The goal was to evaluate the chemical stabilities of methyl-prednisolone sodium succinate packaged in a dual chamber vial, as a specific container closure system. The effect of different parameters: temperature, moisture and light were monitored. The method propose...

  16. Syringe injectable electronics

    Science.gov (United States)

    Hong, Guosong; Zhou, Tao; Jin, Lihua; Duvvuri, Madhavi; Jiang, Zhe; Kruskal, Peter; Xie, Chong; Suo, Zhigang; Fang, Ying; Lieber, Charles M.

    2015-01-01

    Seamless and minimally-invasive three-dimensional (3D) interpenetration of electronics within artificial or natural structures could allow for continuous monitoring and manipulation of their properties. Flexible electronics provide a means for conforming electronics to non-planar surfaces, yet targeted delivery of flexible electronics to internal regions remains difficult. Here, we overcome this challenge by demonstrating syringe injection and subsequent unfolding of submicrometer-thick, centimeter-scale macroporous mesh electronics through needles with a diameter as small as 100 micrometers. Our results show that electronic components can be injected into man-made and biological cavities, as well as dense gels and tissue, with > 90% device yield. We demonstrate several applications of syringe injectable electronics as a general approach for interpenetrating flexible electronics with 3D structures, including (i) monitoring of internal mechanical strains in polymer cavities, (ii) tight integration and low chronic immunoreactivity with several distinct regions of the brain, and (iii) in vivo multiplexed neural recording. Moreover, syringe injection enables delivery of flexible electronics through a rigid shell, delivery of large volume flexible electronics that can fill internal cavities and co-injection of electronics with other materials into host structures, opening up unique applications for flexible electronics. PMID:26053995

  17. Syringe-injectable electronics.

    Science.gov (United States)

    Liu, Jia; Fu, Tian-Ming; Cheng, Zengguang; Hong, Guosong; Zhou, Tao; Jin, Lihua; Duvvuri, Madhavi; Jiang, Zhe; Kruskal, Peter; Xie, Chong; Suo, Zhigang; Fang, Ying; Lieber, Charles M

    2015-07-01

    Seamless and minimally invasive three-dimensional interpenetration of electronics within artificial or natural structures could allow for continuous monitoring and manipulation of their properties. Flexible electronics provide a means for conforming electronics to non-planar surfaces, yet targeted delivery of flexible electronics to internal regions remains difficult. Here, we overcome this challenge by demonstrating the syringe injection (and subsequent unfolding) of sub-micrometre-thick, centimetre-scale macroporous mesh electronics through needles with a diameter as small as 100 μm. Our results show that electronic components can be injected into man-made and biological cavities, as well as dense gels and tissue, with >90% device yield. We demonstrate several applications of syringe-injectable electronics as a general approach for interpenetrating flexible electronics with three-dimensional structures, including (1) monitoring internal mechanical strains in polymer cavities, (2) tight integration and low chronic immunoreactivity with several distinct regions of the brain, and (3) in vivo multiplexed neural recording. Moreover, syringe injection enables the delivery of flexible electronics through a rigid shell, the delivery of large-volume flexible electronics that can fill internal cavities, and co-injection of electronics with other materials into host structures, opening up unique applications for flexible electronics.

  18. Reactor water injection facility

    Energy Technology Data Exchange (ETDEWEB)

    Yoshikawa, Kazuhiro; Kinoshita, Shoichiro

    1997-05-02

    A steam turbine and an electric generator are connected by way of a speed convertor. The speed convertor is controlled so that the number of rotation of the electric generator is constant irrespective of the speed change of the steam turbine. A shaft coupler is disposed between the turbine and the electric generator or between the turbine and a water injection pump. With such a constitution, the steam turbine and the electric generator are connected by way of the speed convertor, and since the number of revolution of the electric generator is controlled to be constant, the change of the number of rotation of the turbine can be controlled irrespective of the change of the number of rotation of the electric generator. Accordingly, the flow rate of the injection water from the water injection pump to a reactor pressure vessel can be controlled freely thereby enabling to supply stable electric power. (T.M.)

  19. Enteric-coated mycophenolate sodium.

    Science.gov (United States)

    Gabardi, Steven; Tran, Jennifer L; Clarkson, Michael R

    2003-11-01

    To review the pharmacology, pharmacokinetics, efficacy, and safety of mycophenolate sodium. Primary literature was obtained via a MEDLINE search (1966-June 2003). Abstracts were obtained from the manufacturer and included in the analysis. All studies and abstracts evaluating mycophenolate sodium in solid organ transplantation were considered for inclusion. English-language studies and abstracts were selected for inclusion, but were limited to those consisting of human subjects. Mycophenolate sodium, a mycophenolic acid prodrug, is an inhibitor of T-lymphocyte proliferation. Mycophenolic acid reduces the incidence of acute rejection in renal transplantation. Mycophenolate sodium is enteric coated and has been suggested as a potential method to reduce the gastrointestinal adverse events seen with mycophenolate mofetil. Both mycophenolate mofetil and mycophenolate sodium have been shown to be therapeutically equivalent at decreasing the incidence of allograft rejection and loss. The frequency of adverse events is similar between both compounds, with the most common events being diarrhea and leukopenia. Mycophenolate sodium is effective in preventing acute rejection in renal transplant recipients. At doses of 720 mg twice daily, the efficacy and safety profiles are similar to those of mycophenolate mofetil 1000 mg twice daily. Mycophenolate sodium has been approved in Switzerland; approval in the US is pending.

  20. Water simulation of sodium reactors

    International Nuclear Information System (INIS)

    Grewal, S.S.; Gluekler, E.L.

    1981-01-01

    The thermal hydraulic simulation of a large sodium reactor by a scaled water model is examined. The Richardson Number, friction coefficient and the Peclet Number can be closely matched with the water system at full power and the similarity is retained for buoyancy driven flows. The simulation of thermal-hydraulic conditions in a reactor vessel provided by a scaled water experiment is better than that by a scaled sodium test. Results from a correctly scaled water test can be tentatively extrapolated to a full size sodium system

  1. Sodium diffusion in boroaluminosilicate glasses

    DEFF Research Database (Denmark)

    Smedskjaer, Morten M.; Zheng, Qiuju; Mauro, John C.

    2011-01-01

    of isothermal sodium diffusion in BAS glasses by ion exchange, inward diffusion, and tracer diffusion experiments. By varying the [SiO2]/[Al2O3] ratio of the glasses, different structural regimes of sodium behavior are accessed. We show that the mobility of the sodium ions decreases with increasing [SiO2]/[Al2O......Understanding the fundamentals of alkali diffusion in boroaluminosilicate (BAS) glasses is of critical importance for advanced glass applications, e.g., the production of chemically strengthened glass covers for personal electronic devices. Here, we investigate the composition dependence...

  2. A phase 2/3, multicenter, randomized, double-masked, 2-year trial of pegaptanib sodium for the treatment of diabetic macular edema

    DEFF Research Database (Denmark)

    Sultan, Marla B; Zhou, Duo; Loftus, Jane

    2011-01-01

    To confirm the safety and compare the efficacy of intravitreal pegaptanib sodium 0.3 mg versus sham injections in subjects with diabetic macular edema (DME) involving the center of the macula associated with vision loss not due to ischemia.......To confirm the safety and compare the efficacy of intravitreal pegaptanib sodium 0.3 mg versus sham injections in subjects with diabetic macular edema (DME) involving the center of the macula associated with vision loss not due to ischemia....

  3. The design, construction, commissioning and operation of a plant at Dounreay to dispose of sodium from KNKII

    International Nuclear Information System (INIS)

    Bowser, R.; Farquhar, J.; Currie, R.

    1997-01-01

    In a competitive bidding exercise, AEA Technology at Dounreay won a contract to dispose of 88 tonnes of fast reactor sodium from the KNKII reactor at KarIsruhe, Germany. This sodium comprises of 36 tonnes of 'primary' sodium containing traces of caesium-137 and sodium-22 and 52 tonnes of lightly tritiated 'secondary' sodium. The sodium has been transported solid to Dounreay in 200 litre drums. To fulfil this contract a sodium disposal plant has been designed, constructed, commissioned and put into operation. Following an option study, an aqueous reaction plant design was selected. In this process, sodium is reacted with aqueous caustic soda, producing hydrogen gas and more caustic soda. The hydrogen is diluted with air and vented to atmosphere, and the caustic is neutralised with hydrochloric acid before discharge to the site low-active drain. All effluents - gaseous or liquid - are filtered and treated to remove as much radioactivity as possible before discharge. The main reasons for choosing this design option were that the process was well proven, the reaction is easily controlled by controlling the supply of sodium into the reaction vessel, reaction temperatures are relatively low and the effluent can be easily prepared for discharge. It was also felt that an aqueous reaction plant could be designed to be operated remotely by one operator. The sodium in the drums is melted in a sodium melting station and then drained to a sodium buffer tank, prior to being injected into the reaction vessel. By collecting sodium in the buffer tank, sodium melting can proceed in parallel with sodium disposal allowing a high throughput to be achieved. This plant has been designed to dispose of 100 kg of sodium per hour, requiring a small operating team, suitably shielded from the radiological hazard. The design also ensures that the rate of reaction is controlled and that the effluent discharged to the low-active drain has been properly neutralised. The construction was performed

  4. Sodium leakage experience at the prototype FBR Monju

    International Nuclear Information System (INIS)

    Miyakawa, A.; Maeda, H.; Kani, Y.; Ito, K.

    2000-01-01

    reduce the amount of sodium leakage and damage by spilt sodium, the drain system will be remodeled to shorten the drain time; To extinguish a sodium fire in the secondary circuit, a nitrogen gas injection system will be installed; To limit the spread of aerosol, the secondary circuit area will be divided into four smaller zones. These countermeasures will enhance the safety and reliability of the plant with regard to sodium leakage incidents. (author)

  5. Oxygen injection facility

    International Nuclear Information System (INIS)

    Ota, Masamoto; Hirose, Yuki

    1998-01-01

    A compressor introduces air as a starting material and sends it to a dust removing device, a dehumidifying device and an adsorption/separation system disposed downstream. The facility of the present invention is disposed in the vicinity of an injection point and installed in a turbine building of a BWR type reactor having a pipeline of a feedwater system to be injected. The adsorbing/separation system comprises an adsorbing vessel and an automatic valve, and the adsorbing vessel is filled with an adsorbent for selectively adsorbing nitrogen. Zeolite is used as the adsorbent. Nitrogen in the air passing through the adsorbing vessel is adsorbed and removed under a pressurized condition, and a highly concentrated oxygen gas is formed. The direction of the steam of the adsorbed nitrogen is changed by an opening/closing switching operation of an automatic valve and released to the atmosphere (the pressure is released). Generated oxygen gas is stored under pressure in a tank, and injected to the pipeline of the feedwater system by an oxygen injection conduit by way of a flow rate control valve. In the adsorbing vessel, steps of adsorption, separation and storage under pressure are repeated successively. (I.N.)

  6. Water injection dredging

    NARCIS (Netherlands)

    Verhagen, H.J.

    2000-01-01

    Some twenty years ago WIS-dredging has been developed in the Netherlands. By injecting water into the mud layer, the water content of the mud becomes higher, it becomes fluid mud and will start to flow. The advantages of this system are that there is no need of transporting the mud in a hopper, and

  7. Botulinum Neurotoxin Injections

    Science.gov (United States)

    ... botulinum neurotoxin as much art as it is science. It is in your best interest to locate the most well-trained and experienced doctor you can find. Before making an appointment to receive botulinum neuro toxin injections, ask the office personnel which doctor ...

  8. Piperacillin and Tazobactam Injection

    Science.gov (United States)

    ... is in a class of medications called penicillin antibiotics. It works by killing bacteria that cause infection. Tazobactam is ... It works by preventing bacteria from destroying piperacillin.Antibiotics ... injection will not work for colds, flu, or other viral infections. Taking ...

  9. Meropenem and Vaborbactam Injection

    Science.gov (United States)

    ... is in a class of medications called carbapenem antibiotics. It works by killing bacteria. Vaborbactam is in a class ... It works by preventing bacteria from destroying meropenem.Antibiotics such as meropenem and vaborbactam injection will not work for colds, flu, or other viral infections. Taking ...

  10. Cold water injection nozzles

    International Nuclear Information System (INIS)

    Kura, Masaaki; Maeda, Masamitsu; Endo, Takio.

    1979-01-01

    Purpose: To inject cold water in a reactor without applying heat cycles to a reactor container and to the inner wall of a feedwater nozzle by securing a perforated plate at the outlet of the cold water injection nozzle. Constitution: A disc-like cap is secured to the final end of a return nozzle of a control rod drive. The cap prevents the flow of a high temperature water flowing downward in the reactor from entering into the nozzle. The cap is perforated with a plurality of bore holes for injecting cold water into the reactor. The cap is made to about 100 mm in thickness so that the cold water passing through the bore holes is heated by the heat conduction in the cap. Accordingly, the flow of high temperature water flowing downwardly in the reactor is inhibited by the cap from backward flowing into the nozzle. Moreover, the flow of the cold water in the nozzle is controlled and rectified when passed through the bore holes in the cap and then injected into the reactor. (Yoshino, Y.)

  11. Pellet injection in WVIIA

    International Nuclear Information System (INIS)

    Renner, H.; Wuersohing, E.; Weller, A.; Jaeckel, H.; Hartfuss, H.; Hacker, H.; Ringler, H.; Buechl, K.

    1986-01-01

    The results of pellet injection experiments in the Wendelstein VII A stellarator are presented. The injector was a single shot pneumatic gun using deuterium pellets. Experiments were carried out in both ECRH and NI plasmas. Data is shown for plasma density, energy confinement, penetration depth and pellet ablation. Results are compared to a neutral gas shielding model

  12. Magnetron injection gun scaling

    International Nuclear Information System (INIS)

    Lawson, W.

    1988-01-01

    Existing analytic design equations for magnetron injection guns (MIG's) are approximated to obtain a set of scaling laws. The constraints are chosen to examine the maximum peak power capabilities of MIG's. The scaling laws are compared with exact solutions of the design equations and are supported by MIG simulations

  13. RHIC injection kicker impedance

    International Nuclear Information System (INIS)

    Mane, V.; Peggs, S.; Trbojevic, D.; Zhang, W.

    1995-01-01

    The longitudinal impedance of the RHIC injection kicker is measured using the wire method up to a frequency of 3 GHz. The mismatch between the 50 ohm cable and the wire and pipe system is calibrated using the TRL calibration algorithm. Various methods of reducing the impedance, such as coated ceramic pipe and copper strips are investigated

  14. SPS injection kicker magnet

    CERN Document Server

    1975-01-01

    One of the first-generation SPS injection kicker magnets. Lifting the tank-lid reveals the inner structure. For a more detailed description see 7502072X. See also 7502074X and Annual Report 1975, p.162. To the left: Roland Tröhler; to the right: Giacomo Busetta.

  15. In situ Microscopic Observation of Sodium Deposition/Dissolution on Sodium Electrode

    OpenAIRE

    Yuhki Yui; Masahiko Hayashi; Jiro Nakamura

    2016-01-01

    Electrochemical sodium deposition/dissolution behaviors in propylene carbonate-based electrolyte solution were observed by means of in situ light microscopy. First, granular sodium was deposited at pits in a sodium electrode in the cathodic process. Then, the sodium particles grew linearly from the electrode surface, becoming needle-like in shape. In the subsequent anodic process, the sodium dissolved near the base of the needles on the sodium electrode and the so-called ?dead sodium? broke a...

  16. Parametric Effect of Sodium Hydroxide and Sodium Carbonate on the Potency of a Degreaser

    OpenAIRE

    Babatope Abimbola Olufemi

    2016-01-01

    Experimental and statistical analysis was carried out on the comparative effect of sodium hydroxide and sodium carbonate on the potency of a laboratory produced degreaser in this work. The materials used include; octadecyl benzene sulphonic acid, sodium hydroxide, sodium carbonate, sodium metasilicate, carboxyl methyl cellulose (C.M.C), formadelhyde, perfume, colourant and distilled water. Different samples of degreaser were produced with varying composition of sodium hydroxide and sodium car...

  17. Radiotracer injections through microfilters

    International Nuclear Information System (INIS)

    Huber, H.; Maschek, G.; Pichler, R.; Giesen, I.; Hatzl-Griesenhofer, M.; Maschek, W.

    2002-01-01

    Full text: Problems with the injection of radiotracers ( 99m Tc-HAMS, 99m Tc-DPD) to infants when administered through polar-filter-protected venous pathways caused us to get a closer look of what happens to a tracer in such a system. We simulated injections of the tracers mainly used at our institution in an in-vitro array and measured full and empty tracer syringes, filters (0.2 μm micropores) and the post-filter receptacle of the radioactivity. We calculated the percentage of filter-trapped activity and of activity in the receptacle. For several tracers we repeated this process with a neutral filter of the same pore size to get a comparison between the behavior in polarized and electrically inert filters. In general injection of a soluble radiotracer through a polar filter system means a dose loss in the filter of about 10 %, up to the tracer molecule size of IgG-antibodies. Suspended tracers, which consist of comparatively large particles, like RES- or pulmonary perfusion markers, are blocked by the filter, as can be foreseen with a particle size of >> 0.2 μm. DMSA and DPD (a biphosphonate), although both being soluble and rather small molecules, were blocked by the polar filter to a high extent, and by the neutral filter to a much lower, almost neglectable degree. The conclusions are: if possible avoid any use of a filter in your tracer injection pathway. Never use a filter with bone scan or DMSA applications. When doing uptake calculations you have to add the filter counts to the empty syringe value in the formula. If you cannot avoid to inject the radiotracer through a filter you have to replace the filter afterwards and treat the used filter as radioactive waste. The polarity of the filter material might severely affect retention of radiotracer in the filter. (author)

  18. Sodium concrete reaction - Structural considerations

    International Nuclear Information System (INIS)

    Ferskakis, G.N.

    1984-01-01

    An overview of the sodium concrete reaction phenomenon, with emphasis on structural considerations, is presented. Available test results for limestone, basalt, and magnetite concrete with various test article configurations are reviewed. Generally, tests indicate reaction is self limiting before all sodium is used. Uncertainties, however, concerning the mechanism for penetration of sodium into concrete have resulted in different theories about a reaction model. Structural behavior may be significant in the progression of the reaction due to thermal-structuralchemical interactions involving tensile cracking, compressive crushing, or general deterioration of concrete and the exposure of fresh concrete surfaces to react with sodium. Structural behavior of test articles and potential factors that could enhance the progression of the reaction are discussed

  19. Borocaptate sodium (BSH) toxicity issues

    International Nuclear Information System (INIS)

    LaHann, T.

    1995-01-01

    ISU's Center for Toxicology Research has been conducting toxicity testing of borocaptate sodium (BSH) to aid in assessing if proposed human studies of BSH are likely to be acceptably safe. This report describes BSH interactions with other biological agents

  20. Tennis elbow: role of local steroid injection.

    Science.gov (United States)

    Ahmed, Gulzar Saeed; Ali, Muhammad; Trago, Imtiaz Ahmed

    2012-01-01

    Tennis elbow is a condition, characterised by pain and tenderness over the lateral epicondyle of the humerus, and pain on resisted dorsiflexion of the wrist, middle finger, or both. The aim of this randomised controlled trial was to investigate the short term efficacy of local steroid injection compared with oral and topical NSAIDs. Sixty patients (45 male and 15 female) were included in the study. The mean age was 42 years for men and 40 years for women. They were placed in group A and B (30 cases each). Group A received local steroid injection (triamcinolone 20 mg mixed with lignocaine 2% 1 cc) and topical NSAID cream application (diclofenac diethylammonium) twice a day, tab. diclofenac sodium 50 mg twice a day for 3 weeks. Group B received tab diclofenac 50 mg twice a day and, topical NSAID cream application twice a day for 3 weeks. Assessment of patients was made 3 times; first at the start of the study, 2nd time after 6 weeks, and 3rd time after 12 weeks. A blinded assessor rated the elbow complaints of the patients at resisted dorsiflexion of wrist using VAS (0 = no severity, 1-3 mild, 4-6 moderate, 7-9 sever, 10 = maximum severity). At six weeks, 22 (73.33%) patient in group A had no pain as compared to 7 (23.33%) patients in group B who were pain free (p < 0.0001, chi2 = 38.75). At 12 weeks 27 (90%) patients in group A were pain free compared to group B in which 7 (23.33%) patients were pain free (p < 0.0001, chi2 = 27.56). In patients with tennis elbow, the use of local steroid injection in combination with topical and oral NSAIDs is superior to the use of combination of topical and oral NSAIDs. Better results with combination therapy using local steroid injection may be limited to the short term.

  1. Ultrasonic imaging in liquid sodium

    Energy Technology Data Exchange (ETDEWEB)

    Lubeigt, E. [CEA Cadarache, DEN/DTN/STCP/LIET, 13108 Saint-Paul-Lez-Durance Cedex (France); Laboratoire de Mecanique et d' Acoustique, CNRS UPR 7051, 13402 Marseille Cedex 20 (France); Mensah, S.; Chaix, J.F.; Rakotonarivo, S. [Laboratoire de Mecanique et d' Acoustique, CNRS UPR 7051, 13402 Marseille Cedex 20 (France); Gobillot, G. [CEA Cadarache, DEN/DTN/STCP/LIET, 13108 Saint-Paul-Lez-Durance Cedex (France)

    2015-07-01

    The fourth generation of nuclear reactor can use liquid sodium as the core coolant. When the reactor is operating, sodium temperatures can reach up to 600 deg. C. During maintenance periods, when the reactor is shut down, the coolant temperature is reduced to 200 deg. C. Because molten sodium is optically opaque, ultrasonic imaging techniques are developed for maintenance activities. Under-sodium imaging aims at i) checking the health of immersed structures. It should also allow ii) to assess component degradation or damage as cracks and shape defects as well as iii) the detection of lost objects. The under-sodium imaging system has to sustain high temperature (up to 300 deg. C) and hostility of the sodium environment. Furthermore, specific constraints such as transducers characteristics or the limited sensor mobility in the reactor vessel have to be considered. This work focuses on developing a methodology for detecting damages such as crack defects with ultrasound devices. Surface-breaking cracks or deep cracks are sought in the weld area, as welds are more subject to defects. Traditional methods enabled us to detect emerging cracks of submillimeter size with sodium-compatible high-temperature transducer. The presented approach relies on making use of prior knowledge about the environment through the implementation of differential imaging and time-reversal techniques. Indeed, this approach allows to detect a change by comparison with a reference measurement and by focusing back to any change in the environment. It is a means of analysis and understanding of the physical phenomena making it possible to design more effective inspection strategies. Difference between the measured signals reveals the acoustic field scattered by a perturbation (a crack for instance), which may occur between periodical measurements. The imaging method relies on the adequate combination of two computed ultrasonic fields, one forward and one adjoint. The adjoint field, which carries the

  2. Ultrasonic imaging in liquid sodium

    International Nuclear Information System (INIS)

    Lubeigt, E.; Mensah, S.; Chaix, J.F.; Rakotonarivo, S.; Gobillot, G.

    2015-01-01

    The fourth generation of nuclear reactor can use liquid sodium as the core coolant. When the reactor is operating, sodium temperatures can reach up to 600 deg. C. During maintenance periods, when the reactor is shut down, the coolant temperature is reduced to 200 deg. C. Because molten sodium is optically opaque, ultrasonic imaging techniques are developed for maintenance activities. Under-sodium imaging aims at i) checking the health of immersed structures. It should also allow ii) to assess component degradation or damage as cracks and shape defects as well as iii) the detection of lost objects. The under-sodium imaging system has to sustain high temperature (up to 300 deg. C) and hostility of the sodium environment. Furthermore, specific constraints such as transducers characteristics or the limited sensor mobility in the reactor vessel have to be considered. This work focuses on developing a methodology for detecting damages such as crack defects with ultrasound devices. Surface-breaking cracks or deep cracks are sought in the weld area, as welds are more subject to defects. Traditional methods enabled us to detect emerging cracks of submillimeter size with sodium-compatible high-temperature transducer. The presented approach relies on making use of prior knowledge about the environment through the implementation of differential imaging and time-reversal techniques. Indeed, this approach allows to detect a change by comparison with a reference measurement and by focusing back to any change in the environment. It is a means of analysis and understanding of the physical phenomena making it possible to design more effective inspection strategies. Difference between the measured signals reveals the acoustic field scattered by a perturbation (a crack for instance), which may occur between periodical measurements. The imaging method relies on the adequate combination of two computed ultrasonic fields, one forward and one adjoint. The adjoint field, which carries the

  3. Too Much Sodium PSA (:60)

    Centers for Disease Control (CDC) Podcasts

    This 60 second PSA is based on the February 2012 CDC Vital Signs report. Ninety percent of Americans age two and older eat too much sodium which can increase your risk for high blood pressure and often leads to heart disease and stroke, two leading causes of death in the US. Learn several small steps you can take to reduce the amount of sodium in your diet.

  4. Time series geophysical monitoring of permanganate injections and in situ chemical oxidation of PCE, OU1 area, Savage Superfund Site, Milford, NH, USA

    Science.gov (United States)

    Harte, Philip T.; Smith, Thor E.; Williams, John H.; Degnan, James R.

    2012-01-01

    In situ chemical oxidation (ISCO) treatment with sodium permanganate, an electrically conductive oxidant, provides a strong electrical signal for tracking of injectate transport using time series geophysical surveys including direct current (DC) resistivity and electromagnetic (EM) methods. Effective remediation is dependent upon placing the oxidant in close contact with the contaminated aquifer. Therefore, monitoring tools that provide enhanced tracking capability of the injectate offer considerable benefit to guide subsequent ISCO injections. Time-series geophysical surveys were performed at a superfund site in New Hampshire, USA over a one-year period to identify temporal changes in the bulk electrical conductivity of a tetrachloroethylene (PCE; also called tetrachloroethene) contaminated, glacially deposited aquifer due to the injection of sodium permanganate. The ISCO treatment involved a series of pulse injections of sodium permanganate from multiple injection wells within a contained area of the aquifer. After the initial injection, the permanganate was allowed to disperse under ambient groundwater velocities. Time series geophysical surveys identified the downward sinking and pooling of the sodium permanganate atop of the underlying till or bedrock surface caused by density-driven flow, and the limited horizontal spread of the sodium permanganate in the shallow parts of the aquifer during this injection period. When coupled with conventional monitoring, the surveys allowed for an assessment of ISCO treatment effectiveness in targeting the PCE plume and helped target areas for subsequent treatment.

  5. Time series geophysical monitoring of permanganate injections and in situ chemical oxidation of PCE, OU1 area, Savage Superfund Site, Milford, NH, USA.

    Science.gov (United States)

    Harte, Philip T; Smith, Thor E; Williams, John H; Degnan, James R

    2012-05-01

    In situ chemical oxidation (ISCO) treatment with sodium permanganate, an electrically conductive oxidant, provides a strong electrical signal for tracking of injectate transport using time series geophysical surveys including direct current (DC) resistivity and electromagnetic (EM) methods. Effective remediation is dependent upon placing the oxidant in close contact with the contaminated aquifer. Therefore, monitoring tools that provide enhanced tracking capability of the injectate offer considerable benefit to guide subsequent ISCO injections. Time-series geophysical surveys were performed at a superfund site in New Hampshire, USA over a one-year period to identify temporal changes in the bulk electrical conductivity of a tetrachloroethylene (PCE; also called tetrachloroethene) contaminated, glacially deposited aquifer due to the injection of sodium permanganate. The ISCO treatment involved a series of pulse injections of sodium permanganate from multiple injection wells within a contained area of the aquifer. After the initial injection, the permanganate was allowed to disperse under ambient groundwater velocities. Time series geophysical surveys identified the downward sinking and pooling of the sodium permanganate atop of the underlying till or bedrock surface caused by density-driven flow, and the limited horizontal spread of the sodium permanganate in the shallow parts of the aquifer during this injection period. When coupled with conventional monitoring, the surveys allowed for an assessment of ISCO treatment effectiveness in targeting the PCE plume and helped target areas for subsequent treatment. Published by Elsevier B.V.

  6. Role of aquaporin and sodium channel in pleural water movement.

    Science.gov (United States)

    Jiang, Jinjun; Hu, Jie; Bai, Chunxue

    2003-12-16

    The role of the ENaC sodium channel and aquaporin-1 (AQP1) water channel on pleural fluid dynamics in mice was investigated. 0.25 ml of hypertonic or isosmolar fluid was infused into the pleural space in anesthetized wildtype and AQP1 null mice. Pleural fluid was sampled at specified times to quantify the osmolality and volume. The sodium channel activator terbutaline increased isosmolar fluid clearance by 90% while the sodium channel inhibitor amiloride decreased it by 15%, but had no effect on osmotically driven water transport. AQP1 deletion significantly decreased osmotic water transport in pleural space by twofold, but it had no effect on isosmolar fluid clearance. Pretreatment with dexamethasone increased pleural osmotic fluid entry by 25%, while intravenous injection of HgCl2 decreased osmotic pleural water movement by 43%. These results provided evidence for a role of a sodium channel in pleural fluid absorption; AQP1 plays a major role in osmotic liquid transport but it does not affect isosmolar fluid clearance.

  7. Sodium voiding analysis in Kalimer

    International Nuclear Information System (INIS)

    Chang, Won-Pyo; Jeong, Kwan-Seong; Hahn, Dohee

    2001-01-01

    A sodium boiling model has been developed for calculations of the void reactivity feedback as well as the fuel and cladding temperatures in the KALIMER core after onset of sodium boiling. The sodium boiling in liquid metal reactors using sodium as coolant should be modeled because of phenomenon difference observed from that in light water reactor systems. The developed model is a multiple -bubble slug ejection model. It allows a finite number of bubbles in a channel at any time. Voiding is assumed to result from formation of bubbles that fill the whole cross section of the coolant channel except for liquid film left on the cladding surface. The vapor pressure, currently, is assumed to be uniform within a bubble. The present study is focused on not only demonstration of the sodium voiding behavior predicted by the developed model, but also confirmation on qualitative acceptance for the model. In results, the model catches important phenomena for sodium boiling, while further effort should be made for the complete analysis. (author)

  8. Compatibility and stability of aloxi (palonosetron hydrochloride) admixed with dexamethasone sodium phosphate.

    Science.gov (United States)

    Trissel, Lawrence A; Zhang, Yanping

    2004-01-01

    The purpose of this study was to evaluate the physical and chemical stability of palonosetron hydrochloride 0.25 mg admixed with dexamethasone (as sodium phophate) 10 mg or 20 mg in 5% dextrose injection or 0.9% sodium chloride injection in polyvinylchloride minibags, and also admixed with dexamethasone (as sodium phosphate) 3.3 mg in 5% dextrose injection or 0.9% sodium chloride injection in polypropylene syringes, at 4 deg C stored in the dark for 14 days, and at 23 deg C exposed to normal laboratory fluorescent light over 48 hours. Test samples of palonosetron hydrochloride 5 micrograms/mL with dexamethasone (as sodium phosphate) 0.2 mg/mL and also 0.4 mg/mL were prepared in polyvinylchloride minibags of each infusion solution. Additionally, palonosetron hydrochloride 25 micrograms/mL with dexamethasone (as sodium phosphate) 0.33 mg/mL in each infusion solution were prepared as 10 mL of test solution in 20-mL polypropylene syringes. Evaluations for physical and chemical stability were performed on samples taken initially and after 1, 3, 7 and 14 days of storage at 4 deg C and after 1, 4, 24 and 48 hours at 23 deg C. Physical stability was assessed using visual observation in normal room light and using a high-intensity monodirectional light beam. In addition, turbidity and particle content were measured electronically. Chemical stability of the drug was evaluated by using a stability-indicating high-performance liquid chromatographic analytical technique. All samples were physically compatible throughout the study. The solutions remained clear and showed little or no change in particulate burden and haze level. Additionally, little or no loss of palonosetron hydrochloride and dexamethasone occurred in any of the samples at either temperature throughout the entire study period. Admixtures of palonosetron hydrochloride with dexamethasone sodium phosphate in 5% dextrose injection or in 0.9% sodium chloride injection packaged in polyvinylchloride minibags or in

  9. Histological responses of cutaneous vascular lesions following photodynamic therapy with talaporfin sodium: a chicken comb model.

    Science.gov (United States)

    Ohshiro, Takafumi; Nakajima, Tatsuo; Ogata, Hisao; Kishi, Kazuo

    2009-09-01

    Mono-L-aspartyl chlorin e6 (Talaporfin sodium) is a novel photosensitizer, and is currently being used in photodynamic therapy for various malignant tumors in combination with irradiation with a 664 nm laser. An interesting characteristic of Talaporfin sodium is that the skin photosensitivity after injection of this agent disappears faster than any other existing photosensitizers. This study examined the vascular events that occurred postirradiation in the chicken comb as a capillary malformation model after photosensitization with Talaporfin sodium. A single intravenous bolus injections of Talaporfin sodium was administered to the chickens, and a 1 cm diameter area of the comb of each animal was irradiated with a 664 nm visible red laser. The gross changes in the chicken combs were recorded for 7-14 days after photodynamic therapy. For the histological examination, HE, PTAH and Azan stained sections were analyzed. All treated chicken combs had blanched after photodynamic therapy. Microscopy demonstrated an absence of erythrocytes and the vessel lumina were obliterated, leaving the normal overlying epidermis completely intact. Concomitantly with selective destruction of the capillaries in the target area, moderate invasion of inflammatory cells and a slight increase in the stroma were observed. In the chicken comb model, photodynamic therapy with Talaporfin sodium effectively achieved selective destruction of the microvasculature while leaving the epidermis intact. Our results strongly suggest that photodynamic therapy with Talaporfin sodium could be a feasible method to treat dermal hypervascular lesions.

  10. 21 CFR 522.460 - Cloprostenol sodium.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Cloprostenol sodium. 522.460 Section 522.460 Food... Cloprostenol sodium. (a)(1) Specifications. Each milliliter of the aqueous solution contains 263 micrograms of cloprostenol sodium (equivalent to 250 micrograms of cloprostenol) in a sodium citrate, anhydrous citric acid...

  11. Are Reductions in Population Sodium Intake Achievable?

    Directory of Open Access Journals (Sweden)

    Jessica L. Levings

    2014-10-01

    Full Text Available The vast majority of Americans consume too much sodium, primarily from packaged and restaurant foods. The evidence linking sodium intake with direct health outcomes indicates a positive relationship between higher levels of sodium intake and cardiovascular disease risk, consistent with the relationship between sodium intake and blood pressure. Despite communication and educational efforts focused on lowering sodium intake over the last three decades data suggest average US sodium intake has remained remarkably elevated, leading some to argue that current sodium guidelines are unattainable. The IOM in 2010 recommended gradual reductions in the sodium content of packaged and restaurant foods as a primary strategy to reduce US sodium intake, and research since that time suggests gradual, downward shifts in mean population sodium intake are achievable and can move the population toward current sodium intake guidelines. The current paper reviews recent evidence indicating: (1 significant reductions in mean population sodium intake can be achieved with gradual sodium reduction in the food supply, (2 gradual sodium reduction in certain cases can be achieved without a noticeable change in taste or consumption of specific products, and (3 lowering mean population sodium intake can move us toward meeting the current individual guidelines for sodium intake.

  12. Influence of high-conductivity buffer composition on field-enhanced sample injection coupled to sweeping in CE.

    Science.gov (United States)

    Anres, Philippe; Delaunay, Nathalie; Vial, Jérôme; Thormann, Wolfgang; Gareil, Pierre

    2013-02-01

    The aim of this work was to clarify the mechanism taking place in field-enhanced sample injection coupled to sweeping and micellar EKC (FESI-Sweep-MEKC), with the utilization of two acidic high-conductivity buffers (HCBs), phosphoric acid or sodium phosphate buffer, in view of maximizing sensitivity enhancements. Using cationic model compounds in acidic media, a chemometric approach and simulations with SIMUL5 were implemented. Experimental design first enabled to identify the significant factors and their potential interactions. Simulation demonstrates the formation of moving boundaries during sample injection, which originate at the initial sample/HCB and HCB/buffer discontinuities and gradually change the compositions of HCB and BGE. With sodium phosphate buffer, the HCB conductivity increased during the injection, leading to a more efficient preconcentration by staking (about 1.6 times) than with phosphoric acid alone, for which conductivity decreased during injection. For the same injection time at constant voltage, however, a lower amount of analytes was injected with sodium phosphate buffer than with phosphoric acid. Consequently sensitivity enhancements were lower for the whole FESI-Sweep-MEKC process. This is why, in order to maximize sensitivity enhancements, it is proposed to work with sodium phosphate buffer as HCB and to use constant current during sample injection. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  13. Prototype demonstration of dual sorbent injection for acid gas control on municipal solid waste combustion units

    Energy Technology Data Exchange (ETDEWEB)

    None

    1994-05-01

    This report gathered and evaluated emissions and operations data associated with furnace injection of dry hydrated lime and duct injection of dry sodium bicarbonate at a commercial, 1500 ton per day, waste-to-energy facility. The information compiled during the project sheds light on these sorbents to affect acid gas emissions from municipal solid waste combustors. The information assesses the capability of these systems to meet the 1990 Clean Air Act and 1991 EPA Emission Guidelines.

  14. The dismantling of fast reactors: sodium processing

    International Nuclear Information System (INIS)

    Rodriguez, G.; Berte, M.; Serpante, J.P.

    1999-01-01

    Fast reactors require a coolant that does not slow down neutrons so water can not be used. Metallic sodium has been chosen because of its outstanding neutronic and thermal properties but sodium reacts easily with air and water and this implies that sodium-smeary components can not be considered as usual nuclear wastes. A stage of sodium neutralizing is necessary in the processing of wastes from fast reactors. Metallic sodium is turned into a chemically stable compound: soda, carbonates or sodium salts. This article presents several methods used by Framatome in an industrial way when dismantling sodium-cooled reactors. (A.C.)

  15. Injection-controlled laser resonator

    Science.gov (United States)

    Chang, J.J.

    1995-07-18

    A new injection-controlled laser resonator incorporates self-filtering and self-imaging characteristics with an efficient injection scheme. A low-divergence laser signal is injected into the resonator, which enables the injection signal to be converted to the desired resonator modes before the main laser pulse starts. This injection technique and resonator design enable the laser cavity to improve the quality of the injection signal through self-filtering before the main laser pulse starts. The self-imaging property of the present resonator reduces the cavity induced diffraction effects and, in turn, improves the laser beam quality. 5 figs.

  16. A Patient with MSUD: Acute Management with Sodium Phenylacetate/Sodium Benzoate and Sodium Phenylbutyrate

    OpenAIRE

    K?se, Melis; Canda, Ebru; Kagnici, Mehtap; U?ar, Sema Kalkan; ?oker, Mahmut

    2017-01-01

    In treatment of metabolic imbalances caused by maple syrup urine disease (MSUD), peritoneal dialysis, and hemofiltration, pharmacological treatments for elimination of toxic metabolites can be used in addition to basic dietary modifications. Therapy with sodium phenylacetate/benzoate or sodium phenylbutyrate (NaPB) in urea-cycle disorder cases has been associated with a reduction in branched-chain amino acid (BCAA) concentrations when the patients are on adequate dietary protein intake. Moreo...

  17. Ceramic injection molding

    International Nuclear Information System (INIS)

    Agueda, Horacio; Russo, Diego

    1988-01-01

    Interest in making complex net-shape ceramic parts with good surface finishing and sharp tolerances without machining is a driving force for studying the injection molding technique. This method consists of softhening the ceramic material by means of adding some plastic and heating in order to inject the mixture under pressure into a relatively cold mold where solidification takes place. Essentially, it is the same process used in thermoplastic industry but, in the present case, the ceramic powder load ranges between 80 to 90 wt.%. This work shows results obtained from the fabrication of pieces of different ceramic materials (alumina, barium titanate ferrites, etc.) in a small scale, using equipments developed and constructed in the laboratory. (Author) [es

  18. Gaseous poison injection device

    International Nuclear Information System (INIS)

    Kubota, Ryuji; Sugisaki, Toshihiko; Inada, Ikuo.

    1983-01-01

    Purpose: To rapidly control the chain reaction due to thermal neutrons in a reactor core by using gaseous poisons as back-up means for control rod drives. Constitution: Gaseous poisons having a large neutron absorption cross section are used as back-up means for control rod drives. Upon failure of control rod insertion, the gaseous poisons are injected into the lower portion of the reactor core to control the reactor power. As the gaseous poisons, vapors at a high temperature and a higher pressure than that of the coolants in the reactor core are injected to control the reactor power due to the void effects. Since the gaseous poisons thus employed rapidly reach the reactor core and form gas bubbles therein, the deccelerating effect of the thermal neutrons is decreased to reduce the chain reaction. (Moriyama, K.)

  19. SPEAR 3 INJECTION KICKER

    International Nuclear Information System (INIS)

    2002-01-01

    The design of the SPEAR 3 injection kicker system is presented. This system will include three kicker magnets and their associated pulsers. The magnet design is based on the DELTA kicker magnets, which present a low RF impedance to the beam, and are relatively straight-forward to construct. The pulsers use cascaded IGBT stages that are based on the modulator pulsers developed by a SLAC/LLNL collaboration for the NLC. Design considerations and the results of prototype tests will be discussed

  20. Gallium arsenide injection lasers

    International Nuclear Information System (INIS)

    Thompson, G.H.B.

    1975-01-01

    The semiconductor injection laser includes a thin inner GaAs p-n junction layer between two outer GaAlAs layers which are backed by further thin outer GaAlAs layers with a heavier doping of AlAs. This reduces optical losses. Optical energy is further confined within the inner layers and the lasing threshold reduced by added outer GaAs layers of low electrical and thermal resistivity

  1. Hydrogen pellet injection device

    International Nuclear Information System (INIS)

    Kanno, Masahiro.

    1992-01-01

    In a hydrogen pellet injection device, a nozzle block having a hydrogen gas supply channel is disposed at the inner side of a main cryogenic housing, and an electric resistor is attached to the block. Further, a nozzle block and a hydrogen gas introduction pipe are attached by way of a thermal insulating spacer. Electric current is supplied to the resistor to positively heat the nozzle block and melt remaining solid hydrogen in the hydrogen gas supply channel. Further, the effect of temperature elevation due to the resistor is prevented from reaching the side of the hydrogen gas introduction pipe by the thermal insulation spacer. That is, the temperature of the nozzle block is directly and positively elevated, to melt the solid hydrogen rapidly. Preparation operation from the injection of the hydrogen pellet to the next injection can be completed in a shorter period of time compared with a conventional case thereby enabling to make the test more efficient. Further, only the temperature of the nozzle block is elevated with no effect of temperature elevation due to the resistor to other components by the thermal insulation flange. (N.H.)

  2. Sodium Velocity Maps on Mercury

    Science.gov (United States)

    Potter, A. E.; Killen, R. M.

    2011-01-01

    The objective of the current work was to measure two-dimensional maps of sodium velocities on the Mercury surface and examine the maps for evidence of sources or sinks of sodium on the surface. The McMath-Pierce Solar Telescope and the Stellar Spectrograph were used to measure Mercury spectra that were sampled at 7 milliAngstrom intervals. Observations were made each day during the period October 5-9, 2010. The dawn terminator was in view during that time. The velocity shift of the centroid of the Mercury emission line was measured relative to the solar sodium Fraunhofer line corrected for radial velocity of the Earth. The difference between the observed and calculated velocity shift was taken to be the velocity vector of the sodium relative to Earth. For each position of the spectrograph slit, a line of velocities across the planet was measured. Then, the spectrograph slit was stepped over the surface of Mercury at 1 arc second intervals. The position of Mercury was stabilized by an adaptive optics system. The collection of lines were assembled into an images of surface reflection, sodium emission intensities, and Earthward velocities over the surface of Mercury. The velocity map shows patches of higher velocity in the southern hemisphere, suggesting the existence of sodium sources there. The peak earthward velocity occurs in the equatorial region, and extends to the terminator. Since this was a dawn terminator, this might be an indication of dawn evaporation of sodium. Leblanc et al. (2008) have published a velocity map that is similar.

  3. Some techniques for sodium removal in CIAE

    International Nuclear Information System (INIS)

    Yuan Waimai; Ding Dejun; Guo Huanfang; Hong Shuzhang; Zhou Shuxia; Shen Fenyang; Yang Zhongmin; Xu Yongxing

    1997-01-01

    In this paper the experiment and application on sodium removal and sodium disposal are presented. Steam-nitrogen process was used in CIAE for cleaning cold traps, sodium vapor traps, a sodium tank. Atomized water-nitrogen process was used for cleaning dummy fuel assembly for CEFR and a sintered stainless steel filter. Sprinkle process was used for cleaning some tubes. Bultylcellosolve was used for cleaning sintered stainless steel filter and sodium flow measurement device. Ethanol alcohol was used for cleaning electromagnetic pump. Paraffin, transformer-oil or their mixture was used for cleaning sodium valves, a sodium vapor trap and sodium-potassium alloy absorber. A small sintered stainless steel filter was distillated in vacuum. A simple sodium disposal device has been served for several years in CIA.E. It can dispose about 10 Kg sodium each time and the disposal process is no-aerosol. It operates in open air for non-radioactive sodium. In recent years a small sodium cleaning plant has been built. It can use atomized water, steam or organic alcohol to removal of sodium. The LAVEL cleaning plant and SLAPSO cleaning plant were introduced from Italy. And CEFR preliminary design on sodium cleaning for spent fuel assembly and on sodium removal-decontamination for large reactor components is introduced. Vapour-nitrogen process is planned to use in them. (author)

  4. Study of the permeability of the various parts of the tubules to sodium and potassium ions

    International Nuclear Information System (INIS)

    Morel, F.; Falbriard, A.

    1959-01-01

    The method of stop flow analysis has been used in rabbits together with radioactive sodium and potassium injected in the middle of a six minutes period of arrest of urine flow during an osmotic diuresis. Urine was subsequently collected in 60 ta 80 mg samples. The specific activities of sodium and potassium suggest that both ions pass directly from the renal interstitial tissue into the urine at different and distinct areas in the tubules. The whole distal segment, including the area of active reabsorption of this ion, is impermeable to sodium in the direction interstitial tissue to lumen. The adjacent, more proximal tubule is, however, extremely permeable. The distal tubular impermeability to potassium is more limited. The specific activity already having reached a maximum at the level of active sodium reabsorption. Reprint of a paper published in 'Revue Francaise d'Etudes Cliniques et Biologiques', n. 5, vol IV, p. 471-474 [fr

  5. Isotopic modeling of water and sodium distribution and exchange kinetics in 7 stable hemodialysis patients

    International Nuclear Information System (INIS)

    Chamoiseau, S.; Bertrou, L.; Pujo, J.M.; Massol, M.

    1988-01-01

    Sequential serum sampling over 24 h. has been performed in 7 hemodialysis patients after simultaneous intra-venous injection of tritiated water and 24 Na. Each time-activity curve fits a biexponential pattern. A compartment analysis leads to describe either a simple but incomplete single compartment model or a much more satisfactory open two-compartment mamillary model featuring 2 intercompartment transfer rate constants k 21 and k 12 , and a loss out of the system, k 01 . These constants can be related to intrabody resistances to sodium and water transfers. Compartment analysis allows a comprehensive quantitated description of the exchange and transfer kinetics of sodium and water throughout the system. Evidence for a sodium reservoir, probably located in bone, can be drawn from the results and leads to propose a strategy for a targetted bone sodium removal [fr

  6. Amphotericin B Lipid Complex Injection

    Science.gov (United States)

    Amphotericin B lipid complex injection is used to treat serious, possibly life-threatening fungal infections in people who did ... respond or are unable to tolerate conventional amphotericin B therapy. Amphotericin B lipid complex injection is in ...

  7. Methods to Compose Sodium Fire Extinguishing Equipment on Sodium Test Facility

    Energy Technology Data Exchange (ETDEWEB)

    Kim, B H; Kim, J M; Jeong, J Y; Choi, B H

    2008-06-15

    Sodium fire is graded 'D' and it is difficult to extinguish sodium fire. In this report, the characteristics of sodium fire and the methods composing the suitable fire extinguishing systems to suppress fire effectively were described.

  8. Methods to Compose Sodium Fire Extinguishing Equipment on Sodium Test Facility

    International Nuclear Information System (INIS)

    Kim, B. H.; Kim, J. M.; Jeong, J. Y.; Choi, B. H.

    2008-06-01

    Sodium fire is graded 'D' and it is difficult to extinguish sodium fire. In this report, the characteristics of sodium fire and the methods composing the suitable fire extinguishing systems to suppress fire effectively were described

  9. Sodium aerosol formation in an argon flow over hot sodium

    International Nuclear Information System (INIS)

    Clement, C.F.; Dolias, M.J.; UKAEA Atomic Energy Research Establishment, Harwell. Thermal Hydraulics Div.)

    1987-01-01

    Vapour evaporation, which partly forms aerosol, occurs when a cold gas flows over a hot liquid. A previous well-mixed model is extended to predict the final vapour plus aerosol content of such a flow in terms of its initial and final temperatures. The predictions are compared to results of the Copacabana II experiment in which argon passed over a sodium pool. Agreement is obtained for the final sodium density at moderate flow rates, and physical reasons are given as to why deviations occur at low and high flow rates. (author)

  10. Inhibitin: a specific inhibitor of sodium/sodium exchange in erythrocytes.

    OpenAIRE

    Morgan, K; Brown, R C; Spurlock, G; Southgate, K; Mir, M A

    1986-01-01

    An inhibitor of ouabain-insensitive sodium/sodium exchange in erythrocytes has been isolated from leukemic promyelocytes. To explore the specific effects of this inhibitor, named inhibitin, sodium transport experiments were carried out in human erythrocytes. Inhibitin reduced ouabain-insensitive bidirectional sodium transport. It did not change net sodium fluxes, had no significant effect on rubidium influx, and did not inhibit sodium-potassium-ATPase activity. The inhibitory effect of inhibi...

  11. Opium can differently alter blood glucose, sodium and potassium in male and female rats.

    Science.gov (United States)

    Karam, Gholamreza Asadi; Rashidinejad, Hamid Reza; Aghaee, Mohammad Mehdi; Ahmadi, Jafar; Rahmani, Mohammad Reza; Mahmoodi, Mehdi; Azin, Hosein; Mirzaee, Mohammad Reza; Khaksari, Mohammad

    2008-04-01

    To determine the effects of opium on serum glucose, potassium and sodium in male and female Wistar rat, opium solution (60 mg/kg) injected intraperitoneally and the same volume of distilled water was used as control (7 rats in each group). Blood samples were collected at 0, 30, 60, 120, 240 and 360 minutes after injection from orbit cavity and the values of serum glucose, sodium (Na(+)) and potassium (K(+)) were measured. The data were then analyzed by the repeated measure ANOVA based on sex and case-control group. P opium solution injection, in female rats compared to a control group. However, the male rats had this rise at 30, 60 and 120 minutes after opium solution injection compared to control group. While serum glucose in male rats was significantly higher than females at 30, 60 and 120 minutes, this value was higher in the female rats at 360 minutes. Therefore, serum glucose alterations following opium injection was significantly different in groups and in the sexes at different times. Sodium (Na(+)) rose at 60, 240 and 360 minutes significantly in all rats compared to control group. However, sodium alteration following opium injection was significantly different only between treated and control groups but sex-independent at all times. Potassium (K(+)) increased significantly at 60, 120, 240 and 360 minutes in male rats, compared to a control group. In female rats K(+) significantly raised at 30, 120, 240 and 360 minutes. Therefore, the alteration of K(+) in male and female rats was found time dependent and sex independent. According to our results, opium increased serum glucose in male and female rats differently, and it interferes with metabolic pathways differently on a gender dependent basis. Opium raised serum Na(+) and K(+), thus it interfere with water regulation and blood pressure via different mechanism.

  12. Effect of Sodium Alginate Addition to Resveratrol on Acute Gouty Arthritis

    Directory of Open Access Journals (Sweden)

    Peng Wang

    2015-04-01

    Full Text Available Objective: Resveratrol has been shown to exert anti-inflammatory and antioxidant effects, while sodium alginate is a common pharmaceutic adjuvant with antioxidative and immunomodulatory properties. We performed an animal study to investigate the effect of sodium alginate addition to resveratrol on acute gouty arthritis. Methods: Twenty-four SPF Wistar mice were randomized to four groups receiving the combination of sodium alginate and resveratrol, resveratrol alone, colchicine, and placebo, respectively. Acute gouty arthritis was induced by injection of 0.05 ml monosodium urate (MSU solution (25g/mL into ankle joint cavity. IL-1β, CCR5, and CXCL10 levels in both serum and synovial fluid were measured using ELISA. NLRP3 expression in the synovial tissues was measured using western plot. Results: The combination of sodium alginate and resveratrol significantly reduced synovial levels of IL-1β, CCR5, and CXCL10 when compared with colchicines, and all P values were less than 0.0001. The combination of sodium alginate and resveratrol was also superior to resveratrol in terms of both serum levels and synovial levels of IL-1β, CCR5, and CXCL10. In addition, resveratrol, with or without sodium alginate, could reduce NLRP3 expression obviously in the synovial tissues. Conclusion: The combination of sodium alginate and resveratrol has better effect over colchicines in treating MSU-induced acute gouty arthritis.

  13. Small leak detection by measuring surface oscillation during sodium-water reaction in steam generator

    International Nuclear Information System (INIS)

    Nei, Hiromichi; Hori, Masao

    1977-01-01

    Small leak sodium-water reaction tests were conducted to develop various kinds of leak detectors for the sodium-heated steam generator in FBR. The super-heated steam was injected into sodium in a reaction vessel having a sodium free surface, simulating the steam generator. The level gauge in the reaction vessel generated the most reliable signal among detectors, as long as the leak rates were relatively high. The level gauge signal was estimated to be the sodium surface oscillation caused by hydrogen bubbles produced in sodium-water reaction. Experimental correlation was derived, predicting the amplitude as a function of leak rate, hydrogen dissolution ratio, bubble rise velocity and other parameters concerned, assuming that the surface oscillation is in proportion to the gas hold-up. The noise amplitude under normal operation without water leak was increased with sodium flow rate and found to be well correlated with Froud number. These two correlations predict that a water leak in a ''MONJU'' class (300 MWe) steam generator could possibly be detected by level gauges at a leak rate above 2 g/sec. (auth.)

  14. Acupuncture Injection Combined with Electrokinetic Injection for Polydimethylsiloxane Microfluidic Devices

    Directory of Open Access Journals (Sweden)

    Ji Won Ha

    2017-01-01

    Full Text Available We recently reported acupuncture sample injection that leads to reproducible injection of nL-scale sample segments into a polydimethylsiloxane (PDMS microchannel for microchip capillary electrophoresis. The advantages of the acupuncture injection in microchip capillary electrophoresis include capability of minimizing sample loss and voltage control hardware and capability of introducing sample plugs into any desired position of a microchannel. However, the challenge in the previous study was to achieve reproducible, pL-scale sample injections into PDMS microchannels. In the present study, we introduce an acupuncture injection technique combined with electrokinetic injection (AICEI technique to inject pL-scale sample segments for microchip capillary electrophoresis. We carried out the capillary zone electrophoresis (CZE separation of FITC and fluorescein, and the mixture of 10 μM FITC and 10 μM fluorescein was separated completely by using the AICEI method.

  15. Analyses of hydrodynamic effects of large sodium-water reactions

    International Nuclear Information System (INIS)

    Sakano, K.; Shindo, Y.; Koishikawa, A.; Maekawa, I.

    1977-01-01

    Large leak sodium-water reactions that would occur in a steam generator of LMFBR causes abrupt changes of pressure and velocity of fluid in a secondary sodium system and relief system. This paper describes SOWACS-III together with its model and method. Results of analyses are also given, the comparison with experimental results of initial pressure spike being included. SOWACS-III treats the system which consists of the steam generator, vessel, valve, pump and pipe, and uses the following models and methods. (1) Components are assumed to be one-dimensional. (2) Pressure wave propagation near a reaction zone, where hydrogen is generated, is analyzed with the spherical co-ordinate (sphere-cylinder model). (3) A moving boundary is formed by contact of sodium with other fluid such as hydrogen and nitrogen. The boundary travels without mixing of sodium and another fluid through the boundary (boundary tracking model). The boundary can be treated not to move from the original place (fixed boundary model). (4) Pressure wave propagation is analyzed by the explicit method of characteristics in one-dimensional Eulerian co-ordinate. (5) Flow-induced force is analyzed by momentum balance. (6) The lateral motion of relief piping caused by the force is analyzed by NASTRAN code. Analyses were carried out for large sodium-water reaction experiments in SWAT-3 rig of PNC by using the sphere-cylinder model. The calculated pressure spike in the reaction vessel was compared with the measured one for a few milliseconds after water injection. The calculated value and measured one were 6.4 ata and 6.7 ata for peak pressure and 0.6 ms and 2.8 ms for rising time, respectively

  16. Experimental and iatrogenic poisoning by sodium selenite in pigs

    Directory of Open Access Journals (Sweden)

    Paulo V. Peixoto

    Full Text Available ABSTRACT: Following a case of iatrogenic selenium poisoning in a young pig, an experimental study was carry out. Sodium selenite was orally and parenterally administered to 13 pigs that were subdivided into three groups (G1, G2 and G3. The animals in groups G1 and G3 received sodium selenite intramuscularly (IM, G1 received a comercial formula, and G3 received sodium selenite mixed with distilled water at different dosages, and those in group G2 were fed commercial sodium selenite. Acute and subacute poisoning was observed in both groups, although the onset of clinical signs was slower in group G2. Only one pig (in group G1 that had received the highest dose showed a peracute course. Apathy, anorexia, dyspnea, vomiting, muscular tremors, proprioceptive deficit, ataxia and paresis of the hind limbs progressing to the front limbs evolving to tetraplegia were observed. Postmortem findings differed whether the animals received the injected (G1 and G3 or oral (G2 sodium selenite. The liver was moderately atrophic in some animals of G2. Some of the animals in groups G1 and G3 presented with lung edema. One pig in G3 had yellowish-brown areas in the ventral horns of the cervical intumescences of the spinal cord. The most important histological changes were present in the ventral horns of the cervical and lumbar intumescences of the spinal cord. In one animal, changes were present in the brainstem and mesencephalon. The initial lesion was a perivascular and astrocyte edema that progressing to lysis and death of astrocytes and neurons. In the chronic stage of the lesions, there were extensive areas of liquefaction necrosis with perivascular lymphocytic and histiocytic infiltration and occasional eosinophils. It seems that disruption of the blood-brain barrier due to astrocyte edema is the most likely mechanism of CNS lesion.

  17. On the use of sodium lignosulphonate for enhanced oil recovery

    Science.gov (United States)

    Azis, M. M.; Rachmadi, H.; Wintoko, J.; Yuliansyah, A. T.; Hasokowati, W.; Purwono, S.; Rochmadi, W.; Murachman, B.

    2017-05-01

    There has been large interest to utilize oil reservoirs in Indonesia by using Enhanced Oil Recovery (EOR) processes. Injection of surfactant as a part of chemical injection technique in EOR is known to aid the mobility and reduction in surface tension. One potential surfactant for EOR application is Sodium Lignosulphonate (SLS) which can be made from various sources particularly empty fruit bunch of oil palm and black liquor from kraft pulp production. Here, we will discuss a number of methods for SLS production which includes lignin isolation techniques and sulphonation reaction. The use of SLS alone as EOR surfactant, however, is often not feasible as the Interfacial Tension (IFT) value of SLS is typically above the order of 10-3 dyne/cm which is mandated for EOR application. Hence, brief discussion on SLS formulation screening is provided which illustrates an extensive labwork experience during the SLS development in our lab.

  18. Finding Balance Between Biological Groundwater Treatment and Treated Injection Water

    Energy Technology Data Exchange (ETDEWEB)

    Carlson, Mark A.; Nielsen, Kellin R.; Byrnes, Mark E.; Simmons, Sally A.; Morse, John J.; Geiger, James B.; Watkins, Louis E.; McFee, Phillip M.; Martins, K.

    2015-01-14

    At the U.S. Department of Energy’s Hanford Site, CH2M HILL Plateau Remediation Company operates the 200 West Pump and Treat which was engineered to treat radiological and chemical contaminants in groundwater as a result of the site’s former plutonium production years. Fluidized bed bioreactors (FBRs) are used to remove nitrate, metals, and volatile organic compounds. Increasing nitrate concentrations in the treatment plant effluent and the presence of a slimy biomass (a typical microorganism response to stress) in the FBRs triggered an investigation of nutrient levels in the system. Little, if any, micronutrient feed was coming into the bioreactors. Additionally, carbon substrate (used to promote biological growth) was passing through to the injection wells, causing biological fouling of the wells and reduced specific injectivity. Adjustments to the micronutrient feed improved microorganism health, but the micronutrients were being overfed (particularly manganese) plugging the injection wells further. Injection well rehabilitation to restore specific injectivity required repeated treatments to remove the biological fouling and precipitated metal oxides. A combination of sulfamic and citric acids worked well to dissolve metal oxides and sodium hypochlorite effectively removed the biological growth. Intensive surging and development techniques successfully removed clogging material from the injection wells. Ultimately, the investigation and nutrient adjustments took months to restore proper balance to the microbial system and over a year to stabilize injection well capacities. Carefully tracking and managing the FBRs and well performance monitoring are critical to balancing the needs of the treatment system while reducing fouling mechanisms in the injection wells.

  19. Water injection profiling

    International Nuclear Information System (INIS)

    Arnold, D.M.

    1982-01-01

    A method of neutron-gamma logging is described, in which water, injected in a cased well borehole with peforations, is irradiated with neutrons of 10 MeV or greater, and subsequent gamma radiation is detected by a pair of detectors along the borehole. Counting rates of detectors are analyzed in terms of two gamma ray energy windows. Linear flow velocity of fluid moving downward within the casing is used in conjunction with count rate data to determine volume flow rates of water moving in other directions. Apparatus includes a sonde with a neutron source and appropriate gamma sensors

  20. MKI UFOs at Injection

    CERN Document Server

    Baer, T; Bartmann, W; Bracco, C; Carlier, E; Chanavat, C; Drosdal, L; Garrel, N; Goddard, B; Kain, V; Mertens, V; Uythoven, J; Wenninger, J; Zerlauth, M

    2011-01-01

    During the MD, the production mechanism of UFOs at the injection kicker magnets (MKIs) was studied. This was done by pulsing the MKIs on a gap in the circulating beam, which led to an increased number of UFOs. In total 43 UFO type beam loss patterns at the MKIs were observed during the MD. The MD showed that pulsing the MKIs directly induces UFO type beam loss patterns. From the temporal characteristics of the loss profile, estimations about the dynamics of the UFOs are made.

  1. SQL Injection Defenses

    CERN Document Server

    Nystrom, Martin

    2007-01-01

    This Short Cut introduces you to how SQL injection vulnerabilities work, what makes applications vulnerable, and how to protect them. It helps you find your vulnerabilities with analysis and testing tools and describes simple approaches for fixing them in the most popular web-programming languages. This Short Cut also helps you protect your live applications by describing how to monitor for and block attacks before your data is stolen. Hacking is an increasingly criminal enterprise, and web applications are an attractive path to identity theft. If the applications you build, manage, or guar

  2. LMFBR safety and sodium boiling

    Energy Technology Data Exchange (ETDEWEB)

    Hinkle, W.D.; Tschamper, P.M.; Fontana, M.H.; Henry, R.E.; Padilla, A. Jr.

    1978-01-01

    Within the U.S. Fast Breeder Reactor Safety R and D Work Breakdown Structure for Line of Assurance 2, Limit Core Damage, the influence of sodium boiling upon the progression and termination of accidents is being studied in loss of flow, transient overpower, loss of piping integrity, loss of shutdown heat removal system and local fault situations. The pertinent analytical and experimental results of this research to date are surveyed and compared with the requirements for demonstrating the effectiveness of this line of assurance. A discussion of specific technical issues concerned with sodium boiling and the need for future development work is also presented.

  3. Neutronic spectrometry measurements in sodium

    International Nuclear Information System (INIS)

    Perlini, G.; Acerbis, S.

    1987-01-01

    Measurements were made of neutronic penetration in sodium, which could serve as a reference and as a benchmark for computer codes. The model employed consisted of an assembly of 7 containers full of sodium for a total of 10 tons and a useful length of almost 4 metres. Measurements were performed at various depths along the central axis of the structure with proton recoil proportional counters. The energy band explored was between 100 and 650 keV. Here we report not only the original spectra of the impulses but also the neutronic spectra found by unfolding with the SPEC-4 code

  4. Too Much Sodium PSA (:60)

    Centers for Disease Control (CDC) Podcasts

    2012-02-07

    This 60 second PSA is based on the February 2012 CDC Vital Signs report. Ninety percent of Americans age two and older eat too much sodium which can increase your risk for high blood pressure and often leads to heart disease and stroke, two leading causes of death in the US. Learn several small steps you can take to reduce the amount of sodium in your diet.  Created: 2/7/2012 by Centers for Disease Control and Prevention (CDC).   Date Released: 2/7/2012.

  5. Modeling of Hydrodynamic Processes at a Large Leak of Water into Sodium in the Fast Reactor Coolant Circuit

    Directory of Open Access Journals (Sweden)

    Sergey Perevoznikov

    2016-10-01

    Full Text Available In this paper, we describe a physicomathematical model of the processes that occur in a sodium circuit with a variable flow cross-section in the case of a water leak into sodium. The application area for this technique includes the possibility of analyzing consequences of this leak as applied to sodium–water steam generators in fast neutron reactors. Hydrodynamic processes that occur in sodium circuits in the event of a water leak are described within the framework of a one-dimensional thermally nonequilibrium three-component gas–liquid flow model (sodium–hydrogen–sodium hydroxide. Consideration is given to the results of a mathematical modeling of experiments involving steam injection into the sodium loop of a circulation test facility. That was done by means of the computer code in which the proposed model had been implemented.

  6. Efficient Spin Injection into Semiconductor

    International Nuclear Information System (INIS)

    Nahid, M.A.I.

    2010-06-01

    Spintronic research has made tremendous progress nowadays for making future devices obtain extra advantages of low power, and faster and higher scalability compared to present electronic devices. A spintronic device is based on the transport of an electron's spin instead of charge. Efficient spin injection is one of the very important requirements for future spintronic devices. However, the effective spin injection is an exceedingly difficult task. In this paper, the importance of spin injection, basics of spin current and the essential requirements of spin injection are illustrated. The experimental technique of electrical spin injection into semiconductor is also discussed based on the experimental experience. The electrical spin injection can easily be implemented for spin injection into any semiconductor. (author)

  7. Efficacy and safety of corticosteroid injections and other injections for management of tendinopathy: a systematic review of randomised controlled trials.

    Science.gov (United States)

    Coombes, Brooke K; Bisset, Leanne; Vicenzino, Bill

    2010-11-20

    Few evidence-based treatment guidelines for tendinopathy exist. We undertook a systematic review of randomised trials to establish clinical efficacy and risk of adverse events for treatment by injection. We searched eight databases without language, publication, or date restrictions. We included randomised trials assessing efficacy of one or more peritendinous injections with placebo or non-surgical interventions for tendinopathy, scoring more than 50% on the modified physiotherapy evidence database scale. We undertook meta-analyses with a random-effects model, and estimated relative risk and standardised mean differences (SMDs). The primary outcome of clinical efficacy was protocol-defined pain score in the short term (4 weeks, range 0-12), intermediate term (26 weeks, 13-26), or long term (52 weeks, ≥52). Adverse events were also reported. 3824 trials were identified and 41 met inclusion criteria, providing data for 2672 participants. We showed consistent findings between many high-quality randomised controlled trials that corticosteroid injections reduced pain in the short term compared with other interventions, but this effect was reversed at intermediate and long terms. For example, in pooled analysis of treatment for lateral epicondylalgia, corticosteroid injection had a large effect (defined as SMD>0·8) on reduction of pain compared with no intervention in the short term (SMD 1·44, 95% CI 1·17-1·71, ptendon rupture). By comparison with placebo, reductions in pain were reported after injections of sodium hyaluronate (short [3·91, 3·54-4·28, peffective than was eccentric exercise. Despite the effectiveness of corticosteroid injections in the short term, non-corticosteroid injections might be of benefit for long-term treatment of lateral epicondylalgia. However, response to injection should not be generalised because of variation in effect between sites of tendinopathy. None. Copyright © 2010 Elsevier Ltd. All rights reserved.

  8. Urinary Sodium and Potassium Excretion and Dietary Sources of Sodium in Maputo, Mozambique

    Directory of Open Access Journals (Sweden)

    Ana Queiroz

    2017-08-01

    Full Text Available This study aimed to evaluate the urinary excretion of sodium and potassium, and to estimate the main food sources of sodium in Maputo dwellers. A cross-sectional evaluation of a sample of 100 hospital workers was conducted between October 2012 and May 2013. Sodium and potassium urinary excretion was assessed in a 24-h urine sample; creatinine excretion was used to exclude unlikely urine values. Food intake in the same period of urine collection was assessed using a 24-h dietary recall. The Food Processor Plus® was used to estimate sodium intake corresponding to naturally occurring sodium and sodium added to processed foods (non-discretionary sodium. Salt added during culinary preparations (discretionary sodium was computed as the difference between urinary sodium excretion and non-discretionary sodium. The mean (standard deviation urinary sodium excretion was 4220 (1830 mg/day, and 92% of the participants were above the World Health Organization (WHO recommendations. Discretionary sodium contributed 60.1% of total dietary sodium intake, followed by sodium from processed foods (29.0% and naturally occurring sodium (10.9%. The mean (standard deviation urinary potassium excretion was 1909 (778 mg/day, and 96% of the participants were below the WHO potassium intake recommendation. The mean (standard deviation sodium to potassium molar ratio was 4.2 (2.4. Interventions to decrease sodium and increase potassium intake are needed in Mozambique.

  9. 76 FR 37129 - Determination That SODIUM FLUORIDE F 18 (Sodium Fluoride F-18) Injection, 10 to 200 Millicuries...

    Science.gov (United States)

    2011-06-24

    ... that have been discontinued from marketing for reasons other than safety or effectiveness. ANDAs that..., Was Not Withdrawn From Sale for Reasons of Safety or Effectiveness AGENCY: Food and Drug... withdrawn from sale for reasons of safety or effectiveness. This determination will allow FDA to approve...

  10. High-pressure sodium lamp

    NARCIS (Netherlands)

    1996-01-01

    A high pressure sodium lamp of the invention is provided with a discharge vessel (20) which is enclosed with intervening space (1) by an outer bulb (10), which space contains a gas-fill with at least 70 mol. % nitrogen gas. Electrodes (30a, 30b) are positioned in the discharge vessel (20) and are

  11. Cavitation problems in sodium valves

    International Nuclear Information System (INIS)

    Elie, X.

    1976-01-01

    Cavitation poses few problems for sodium valves, in spite of the fact that the loops are not pressurized. This is no doubt due to the low flow velocities in the pipes. For auxiliary loop valves we are attempting to standardize performances with respect to cavitation. For economic reasons cavitation thresholds are approached with large diameter valves. (author)

  12. Structure of sodium perbromate monohydrate

    International Nuclear Information System (INIS)

    Blackburn, A.C.; Gallucci, J.C.; Gerkin, R.E.; Reppart, W.J.

    1992-01-01

    NaBrO 4 .H 2 O, M r =184.90, monoclinic, C2/c, a=15.7575(19), b=5.7373(15), c=11.3390(19) A, β=111.193(10)deg. In this structure, there are two inequivalent Na ions, each coordinated by six O atoms. In each of the two types of distorted octahedra, there are three inequivalent Na-O distances; the average Na(1)-O and Na(2)-O distances are 2.379(10) and 2.405(23) A, respectively. The perbromate ion in this structure displays very nearly regular tetrahedral geometry, although it is subject to no symmetry constraints; the average observed Br-O distance is 1.601(4) A, while the average observed O-Br-O angle is 109.5(9)deg. These values agree well with previously reported values. The perbromate ion, but neither of the sodium coordination polyhedra, shows rigid-body behavior. The average rigid-body corrected Br-O distance in the perbromate ion is 1.624(3) A. Refinement of the two inequivalent H atoms permitted detailed analysis of the hydrogen bonding, which is slightly different from that reported for the isomorphic sodium perchlorate monohydrate. Dynamic disordering of the H atoms as detailed by magnetic resonance methods for sodium perchlorate monohydrate is not clearly indicated in our X-ray study of sodium perbromate monohydrate. (orig./GSCH)

  13. Comparison of sodium aerosol codes

    International Nuclear Information System (INIS)

    Dunbar, I.H.; Fermandjian, J.; Bunz, H.; L'homme, A.; Lhiaubet, G.; Himeno, Y.; Kirby, C.R.; Mitsutsuka, N.

    1984-01-01

    Although hypothetical fast reactor accidents leading to severe core damage are very low probability events, their consequences are to be assessed. During such accidents, one can envisage the ejection of sodium, mixed with fuel and fission products, from the primary circuit into the secondary containment. Aerosols can be formed either by mechanical dispersion of the molten material or as a result of combustion of the sodium in the mixture. Therefore considerable effort has been devoted to study the different sodium aerosol phenomena. To ensure that the problems of describing the physical behaviour of sodium aerosols were adequately understood, a comparison of the codes being developed to describe their behaviour was undertaken. The comparison consists of two parts. The first is a comparative study of the computer codes used to predict aerosol behaviour during a hypothetical accident. It is a critical review of documentation available. The second part is an exercise in which code users have run their own codes with a pre-arranged input. For the critical comparative review of the computer models, documentation has been made available on the following codes: AEROSIM (UK), MAEROS (USA), HAARM-3 (USA), AEROSOLS/A2 (France), AEROSOLS/B1 (France), and PARDISEKO-IIIb (FRG)

  14. Sodium alginate hydrogel-based bioprinting using a novel multinozzle bioprinting system.

    Science.gov (United States)

    Song, Seung-Joon; Choi, Jaesoon; Park, Yong-Doo; Hong, Soyoung; Lee, Jung Joo; Ahn, Chi Bum; Choi, Hyuk; Sun, Kyung

    2011-11-01

    Bioprinting is a technology for constructing bioartificial tissue or organs of complex three-dimensional (3-D) structure with high-precision spatial shape forming ability in larger scale than conventional tissue engineering methods and simultaneous multiple components composition ability. It utilizes computer-controlled 3-D printer mechanism or solid free-form fabrication technologies. In this study, sodium alginate hydrogel that can be utilized for large-dimension tissue fabrication with its fast gelation property was studied regarding material-specific printing technique and printing parameters using a multinozzle bioprinting system developed by the authors. A sodium alginate solution was prepared with a concentration of 1% (wt/vol), and 1% CaCl(2) solution was used as cross-linker for the gelation. The two materials were loaded in each of two nozzles in the multinozzle bioprinting system that has a total of four nozzles of which the injection speed can be independently controlled. A 3-D alginate structure was fabricated through layer-by-layer printing. Each layer was formed through two phases of printing, the first phase with the sodium alginate solution and the second phase with the calcium chloride solution, in identical printing pattern and speed condition. The target patterns were lattice shaped with 2-mm spacing and two different line widths. The nozzle moving speed was 6.67 mm/s, and the injection head speed was 10 µm/s. For the two different line widths, two injection needles with inner diameters of 260 and 410 µm were used. The number of layers accumulated was five in this experiment. By varying the nozzle moving speed and the injection speed, various pattern widths could be achieved. The feasibility of sodium alginate hydrogel free-form formation by alternate printing of alginate solution and sodium chloride solution was confirmed in the developed multinozzle bioprinting system. © 2011, Copyright the Authors. Artificial Organs © 2011, International

  15. CDC Vital Signs: Where's the Sodium?

    Science.gov (United States)

    ... in medical costs. Problem Not all foods are created equal Understanding sodium in foods can be confusing ... for lower sodium choices. About 25% comes from restaurants and it can be hard for a person ...

  16. ELTA: Cita{sup trademark}: Sodium measurement

    Energy Technology Data Exchange (ETDEWEB)

    Mauvais, O. [Water Analysis Line Mgr, ELTA (France)

    2002-07-01

    ELTA is pleased to present its last model of Sodium analyzers: CITA 2340: Automatically controlled sodium meter, integrating more automation and performances results respecting costs and wastes reduction. (authors)

  17. Premixed direct injection nozzle

    Science.gov (United States)

    Zuo, Baifang [Simpsonville, SC; Johnson, Thomas Edward [Greer, SC; Lacy, Benjamin Paul [Greer, SC; Ziminsky, Willy Steve [Simpsonville, SC

    2011-02-15

    An injection nozzle having a main body portion with an outer peripheral wall is disclosed. The nozzle includes a plurality of fuel/air mixing tubes disposed within the main body portion and a fuel flow passage fluidly connected to the plurality of fuel/air mixing tubes. Fuel and air are partially premixed inside the plurality of the tubes. A second body portion, having an outer peripheral wall extending between a first end and an opposite second end, is connected to the main body portion. The partially premixed fuel and air mixture from the first body portion gets further mixed inside the second body portion. The second body portion converges from the first end toward said second end. The second body portion also includes cooling passages that extend along all the walls around the second body to provide thermal damage resistance for occasional flame flash back into the second body.

  18. Normal range of human dietary sodium intake

    DEFF Research Database (Denmark)

    McCarron, David A; Kazaks, Alexandra G; Geerling, Joel C

    2013-01-01

    The recommendation to restrict dietary sodium for management of hypertensive cardiovascular disease assumes that sodium intake exceeds physiologic need, that it can be significantly reduced, and that the reduction can be maintained over time. In contrast, neuroscientists have identified neural...... circuits in vertebrate animals that regulate sodium appetite within a narrow physiologic range. This study further validates our previous report that sodium intake, consistent with the neuroscience, tracks within a narrow range, consistent over time and across cultures....

  19. Long-term Effect of Sodium Oxybate (Xyrem®) in Spasmodic Dysphonia with Vocal Tremor

    Science.gov (United States)

    Simonyan, Kristina; Frucht, Steven J.

    2013-01-01

    Background Symptoms of spasmodic dysphonia (SD) are usually managed successfully with botulinum toxin injections. Vocal tremor (VT), which accompanies SD, has a poor response to this treatment. Case Report We report a case of a female with SD and VT who became symptom-free for 10 months after the intake of a single dose of sodium oxybate (Xyrem®). The long-term treatment effect correlated with attenuated brain activity in the key regions of dystonic brain network. Discussion Our case demonstrates that the novel treatment of sodium oxybate may hold promise for SD patients, especially those who have associated VT. PMID:24386608

  20. Long-Term Effect of Sodium Oxybate (Xyrem® in Spasmodic Dysphonia with Vocal Tremor

    Directory of Open Access Journals (Sweden)

    Kristina Simonyan

    2013-12-01

    Full Text Available Background: Symptoms of spasmodic dysphonia (SD are usually managed successfully with botulinum toxin injections. Vocal tremor (VT, which accompanies SD, has a poor response to this treatment.Case Report: We report a case of a female with SD and VT who became symptom‐free for 10 months after the intake of a single dose of sodium oxybate (Xyrem®. The long‐term treatment effect correlated with attenuated brain activity in the key regions of dystonic brain network. Discussion: Our case demonstrates that the novel treatment of sodium oxybate may hold promise for SD patients, especially those who have associated VT.

  1. An automatic system for acidity determination based on sequential injection titration and the monosegmented flow approach.

    Science.gov (United States)

    Kozak, Joanna; Wójtowicz, Marzena; Gawenda, Nadzieja; Kościelniak, Paweł

    2011-06-15

    An automatic sequential injection system, combining monosegmented flow analysis, sequential injection analysis and sequential injection titration is proposed for acidity determination. The system enables controllable sample dilution and generation of standards of required concentration in a monosegmented sequential injection manner, sequential injection titration of the prepared solutions, data collecting, and handling. It has been tested on spectrophotometric determination of acetic, citric and phosphoric acids with sodium hydroxide used as a titrant and phenolphthalein or thymolphthalein (in the case of phosphoric acid determination) as indicators. Accuracy better than |4.4|% (RE) and repeatability better than 2.9% (RSD) have been obtained. It has been applied to the determination of total acidity in vinegars and various soft drinks. The system provides low sample (less than 0.3 mL) consumption. On average, analysis of a sample takes several minutes. Copyright © 2011 Elsevier B.V. All rights reserved.

  2. 49 CFR 173.189 - Batteries containing sodium or cells containing sodium.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 2 2010-10-01 2010-10-01 false Batteries containing sodium or cells containing sodium. 173.189 Section 173.189 Transportation Other Regulations Relating to Transportation PIPELINE AND... Than Class 1 and Class 7 § 173.189 Batteries containing sodium or cells containing sodium. (a...

  3. 21 CFR 556.620 - Sulfabromomethazine sodium.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Sulfabromomethazine sodium. 556.620 Section 556... Tolerances for Residues of New Animal Drugs § 556.620 Sulfabromomethazine sodium. Tolerances for residues of sulfabromomethazine sodium in food are established as follows: (a) In the uncooked edible tissues of cattle at 0.1...

  4. Clinical impact of nonosmotic sodium storage

    NARCIS (Netherlands)

    Olde Engberink, R.H.G.

    2017-01-01

    High sodium intake is associated with hypertension and increased cardiovascular and renal risk. In this thesis we assessed whether these negative effects of sodium can be neutralised by glycosaminoglycans in the endothelial surface layer (i.e. nonosmotic sodium storage). Also, we investigate the

  5. 21 CFR 558.60 - Arsanilate sodium.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Arsanilate sodium. 558.60 Section 558.60 Food and... in Animal Feeds § 558.60 Arsanilate sodium. (a) Appprovals. Type A medicated articles: 20, 50, or 100...) Arsanilate sodium may be used in accordance with the provisions of this section in the combinations provided...

  6. 21 CFR 522.1145 - Hyaluronate sodium.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Hyaluronate sodium. 522.1145 Section 522.1145 Food... Hyaluronate sodium. (a)(1) Specifications. Each milliliter of sterile aqueous solution contains 10 milligrams of hyaluronate sodium. (2) Sponsor. See 000009 in § 510.600(c). (3) Conditions of use—(i) Amount...

  7. Sodium Fire Demonstration Facility Design and Operation

    International Nuclear Information System (INIS)

    Cho, Youngil; Kim, Jong-Man; Lee, Jewhan; Hong, Jonggan; Yeom, Sujin; Cho, Chungho; Jung, Min-Hwan; Gam, Da-Young; Jeong, Ji-Young

    2014-01-01

    Although sodium has good characteristics such as high heat transfer rate and stable nuclear property, it is difficult to manage because of high reactivity. Sodium is solid at the room temperature and it easily reacts with oxygen resulting in fire due to the reaction heat. Thus, sodium must be stored in a chemically stable place, i.e., an inert gas-sealed or oil filled vessel. When a sodium fire occurs, the Na 2 O of white fume is formed. It is mainly composed of Na 2 O 2 , NaOH, and Na 2 CO 3 , ranging from 0.1 to several tens of micrometers in size. It is known that the particle size increases by aggregation during floating in air. Thus, the protection method is important and should be considered in the design and operation of a sodium system. In this paper, sodium fire characteristics are described, and the demonstration utility of outbreak of sodium fire and its extinguishing is introduced. In this paper, sodium fire characteristics and a demonstration facility are described. The introduced sodium fire demonstration facility is the only training device used to observe a sodium fire and extinguish it domestically. Furthermore, the type of sodium fire will be diversified with the enhancement of the utility. It is expected that this utility will contribute to experience in the safe treatment of sodium by the handlers

  8. Sodium Bicarbonate mouth rinse: An Uncommon Complication

    OpenAIRE

    Fatih Mehmet Coskunses

    2012-01-01

    Sodium bicarbonate is a natural buffer that maintains a healthy pH in mouth to promote a clean and fresh oral environment. Sodium-bicarbonate rinse is empirically suggested to patients by dentist and people around, and may prove to be harmful. In this short communication, we present chemical burn of oral mucosa because of sodium-bicarbonate rinse after misfit dental impression.

  9. 21 CFR 582.1748 - Sodium caseinate.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Sodium caseinate. 582.1748 Section 582.1748 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) ANIMAL... Additives § 582.1748 Sodium caseinate. (a) Product. Sodium caseinate. (b) Conditions of use. This substance...

  10. 21 CFR 182.1748 - Sodium caseinate.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Sodium caseinate. 182.1748 Section 182.1748 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) FOOD FOR... Substances § 182.1748 Sodium caseinate. (a) Product. Sodium caseinate. (b) Conditions of use. This substance...

  11. 21 CFR 184.1742 - Sodium carbonate.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Sodium carbonate. 184.1742 Section 184.1742 Food... Specific Substances Affirmed as GRAS § 184.1742 Sodium carbonate. (a) Sodium carbonate (Na2CO3, CAS Reg. No... ore calcined to impure soda ash and then purified; or (3) synthesized from limestone by the Solvay...

  12. Sodium fires and nuclear power station safety

    International Nuclear Information System (INIS)

    Ivanenko, V.N.; Zubin, A.; Drobyshev, A.V.

    1986-01-01

    The danger of sodium aerosol release at a design basis accident (DBA) of a sodium-cooled fast reactor that involves coolant leakage and burning, is being analyzed. It has been shown that radioactive and toxic releases at DBA do not exceed permissible values. Some means of sodium fire fighting are described. (author)

  13. 21 CFR 582.1742 - Sodium carbonate.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Sodium carbonate. 582.1742 Section 582.1742 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) ANIMAL... Additives § 582.1742 Sodium carbonate. (a) Product. Sodium carbonate. (b) Conditions of use. This substance...

  14. Mixed Solvent Reactive Recrystallization of Sodium Carbonate

    NARCIS (Netherlands)

    Gaertner, R.S.

    2005-01-01

    Investigation of the reactive recrystallization of trona (sodium sesquicarbonate) and sodium bicarbonate to sodium carbonate (soda) in a mixed solvent led to the design of several alternative, less energy consumptive, economically very attractive process routes for the production of soda from all

  15. Effects of Pre and Post-Rigor Marinade Injection on Some Quality Parameters of Longissimus Dorsi Muscles

    Science.gov (United States)

    Fadıloğlu, Eylem Ezgi; Serdaroğlu, Meltem

    2018-01-01

    Abstract This study was conducted to evaluate the effects of pre and post-rigor marinade injections on some quality parameters of Longissimus dorsi (LD) muscles. Three marinade formulations were prepared with 2% NaCl, 2% NaCl+0.5 M lactic acid and 2% NaCl+0.5 M sodium lactate. In this study marinade uptake, pH, free water, cooking loss, drip loss and color properties were analyzed. Injection time had significant effect on marinade uptake levels of samples. Regardless of marinate formulation, marinade uptake of pre-rigor samples injected with marinade solutions were higher than post rigor samples. Injection of sodium lactate increased pH values of samples whereas lactic acid injection decreased pH. Marinade treatment and storage period had significant effect on cooking loss. At each evaluation period interaction between marinade treatment and injection time showed different effect on free water content. Storage period and marinade application had significant effect on drip loss values. Drip loss in all samples increased during the storage. During all storage days, lowest CIE L* value was found in pre-rigor samples injected with sodium lactate. Lactic acid injection caused color fade in pre-rigor and post-rigor samples. Interaction between marinade treatment and storage period was found statistically significant (p<0.05). At day 0 and 3, the lowest CIE b* values obtained pre-rigor samples injected with sodium lactate and there were no differences were found in other samples. At day 6, no significant differences were found in CIE b* values of all samples. PMID:29805282

  16. Sodium purification in Rapsodie; La purification du sodium a Rapsodie

    Energy Technology Data Exchange (ETDEWEB)

    Giraud, B [Commissariat a l' Energie Atomique, Dir. des Piles Atomiques, Cadarache (France). Centre d' Etudes Nucleaires

    1968-07-01

    This report is one of a series of publications presenting the main results of tests carried out during the start-up of the first french fast neutron reactor: Rapsodie. The article presents the sodium purification techniques used in the reactor cooling circuits both from the constructional point of view and with respect to results obtained during the first years working. (author) [French] Ce rapport fait partie d'une serie de publications presentant l'essentiel des resultats des essais effectues a l'occasion du demarrage du premier reacteur francais a neutrons rapides: RAPSODIE. Cet article expose les techniques de la purification du sodium utilise dans les circuits de refroidissement du reacteur tant au point de vue de leur realisation technologique, que des resultats obtenus pendant la premiere annee de fonctionnement. (auteur)

  17. SQL Injection Attacks and Defense

    CERN Document Server

    Clarke, Justin

    2012-01-01

    SQL Injection Attacks and Defense, First Edition: Winner of the Best Book Bejtlich Read Award "SQL injection is probably the number one problem for any server-side application, and this book unequaled in its coverage." -Richard Bejtlich, Tao Security blog SQL injection represents one of the most dangerous and well-known, yet misunderstood, security vulnerabilities on the Internet, largely because there is no central repository of information available for penetration testers, IT security consultants and practitioners, and web/software developers to turn to for help. SQL Injection Att

  18. Injectable barriers for waste isolation

    International Nuclear Information System (INIS)

    Persoff, P.; Finsterle, S.; Moridis, G.J.; Apps, J.; Pruess, K.; Muller, S.J.

    1995-03-01

    In this paper the authors report laboratory work and numerical simulation done in support of development and demonstration of injectable barriers formed from either of two fluids: colloidal silica or polysiloxane. Two principal problems addressed here are control of gel time and control of plume emplacement in the vadose zone. Gel time must be controlled so that the viscosity of the barrier fluid remains low long enough to inject the barrier, but increases soon enough to gel the barrier in place. During injection, the viscosity must be low enough to avoid high injection pressures which could uplift or fracture the formation. To test the grout gel time in the soil, the injection pressure was monitored as grouts were injected into sandpacks. When grout is injected into the vadose zone, it slumps under the influence of gravity, and redistributes due to capillary forces as it gels. The authors have developed a new module for the reservoir simulator TOUGH2 to model grout injection into the vadose zone, taking into account the increase of liquid viscosity as a function of gel concentration and time. They have also developed a model to calculate soil properties after complete solidification of the grout. The numerical model has been used to design and analyze laboratory experiments and field pilot tests. The authors present the results of computer simulations of grout injection, redistribution, and solidification

  19. Transformation of sodium from the Rapsodie fast breeder reactor into sodium hydroxide

    International Nuclear Information System (INIS)

    Roger, J.; Latge, C.; Rodriguez, G.

    1994-01-01

    One of the major problems raised by decommissioning a fast breeder reactor (FBR) concerns the disposal of the sodium coolant. The Desora operation was undertaken to eliminate the Rapsodie primary sodium as part of the partial decommissioning program, and to develop an operational sodium treatment unit for other needs. The process involves reacting small quantities of sodium in water inside a closed vessel, producing aqueous sodium hydroxide and hydrogen gas. It is described in this work. (O.L.). 4 figs

  20. Distributed temperature sensor testing in liquid sodium

    Energy Technology Data Exchange (ETDEWEB)

    Gerardi, Craig; Bremer, Nathan; Lisowski, Darius; Lomperski, Stephen

    2017-02-01

    Rayleigh-backscatter-based distributed fiber optic sensors were immersed in sodium to obtain high-resolution liquid-sodium temperature measurements. Distributed temperature sensors (DTSs) functioned well up to 400°C in a liquid sodium environment. The DTSs measured sodium column temperature and the temperature of a complex geometrical pattern that leveraged the flexibility of fiber optics. A single Ø 360 lm OD sensor registered dozens of temperatures along a length of over one meter at 100 Hz. We also demonstrated the capability to use a single DTS to simultaneously detect thermal interfaces (e.g. sodium level) and measure temperature.

  1. Sodium-concrete reaction model development

    International Nuclear Information System (INIS)

    Nguyen, D.H.; Muhlestein, L.D.; Postma, A.K.

    1982-07-01

    Major observations have been formulated after reviewing test results for over 100 sodium-concrete reaction tests. The observations form the basis for developing a mechanistic model to predict the transient behavior of sodium-concrete reactions. The major observations are listed. Mechanisms associated with sodium and water transport to the reaction zone are identified, and represented by appropriate mathematical expressions. The model attempts to explain large-scale, long-term (100 h) test results were sodium-concrete reactions terminated even in the presence of unreacted sodium and concrete

  2. COMPARISON OF ANTI-INFLAMMATORY ACTIVITY OF NIGELLA SATIVA AND DICLOFENAC SODIUM IN ALBINO RATS.

    Science.gov (United States)

    Bashir, Muhammad Usman; Qureshi, Hamid Javaid; Saleem, Tahira

    2015-01-01

    Nigella sativa or "Kalonji" is a naturally occurring plant in Pakistan and other countries which possesses a wide range of medicinal properties, the anti-inflammatory property being one of these. Diclofenac sodium is a commonly used anti-inflammatory drug. The purpose of this study was to compare the anti-inflammatory effect of ethanolic extract of Nigella sativa seeds with that of diclofenac sodium in albino rats. This laboratory randomized controlled trial (RCT) was conducted in the Physiology Department, Services Institute of Medical Sciences (SIMS), Lahore. The study was carried out on 90 male albino rats. Five percent formalin in a dose of 50 µl was injected into sub-plantar surface of right hind paw of each rat to produce inflammation. The rats were randomly divided into three groups of thirty each. Group A was given normal saline (control); group B was given Nigella sativa seed extract; and group C received diclofenac sodium, as a reference drug. Increase in paw diameter, and total and differential leukocyte counts were measured as markers of inflammation. Nigella sativa seeds extract caused significant (pdiclofenac sodium; however, the extract was comparatively less potent than diclofenac sodium. The extract had no significant effect (p>0.05) on the total or differential leukocyte counts. Our results suggest that ethanolic extract of Nigella sativa seeds possesses potent anti-inflammatory effect, in albino rats however, this effect is comparatively less but prolonged than that produced by diclofenac sodium.

  3. Anti-inflammatory Effect of Sodium Valproate on Carrageenan-Induced Paw Edema in Male Rat

    Directory of Open Access Journals (Sweden)

    mj Khoshnood

    2008-12-01

    Full Text Available ABESTRACT: Introduction & objective: Inflammation is a body defensive response to the endogenous and exogenous stimulators such as chemical, radiation, trauma and invasive microorganism, which result pain and tissue necrosis. There are many natural and synthetic drugs for treatment of inflammation and lot of them are under investigation. Sodium valporate is an antiepileptic drug used particularly in the treatment of primary generalized seizure notably absence, myocolonic seizure, acute manic phase of bipolar disorder and prophylaxis of migraine. The previous observations showed sodium valporate increases level of gamma amino butyric acid (GABA in the central and peripheral nervous system. In acute inflammation, GABA showed a significant attenuation of paw edema and nociception. The aim of this study was evaluation of anti-inflammatory effect of sodium valporate. Materials & Methods: In order to evaluated the anti-inflammatory and antiexudative of sodium valporate doses of 200,400 and 600 mg/kg were investigated on rat paw edema that induced by carrageenan. In addition, the plasma leakage in the inflamed tissue was evaluated by application of trypan blue as intravenous injection. Dexamethason was used as positive control. Results: Results showed sodium valporate doses of 400 and 600 mg/kg decreased inflammatory and exudative effect as compared to control group. Conclusion: Although the anti-inflammatory mechanisms of this drug were not evident but we can say sodium valporate in addition to already proved effects has anti-inflammatory effect.

  4. A comparison of molding procedures - Contact, injection and vacuum injection

    Science.gov (United States)

    Cathiard, G.

    1980-06-01

    The technical and economic aspects of the contact, injection and vacuum injection molding of reinforced plastic components are compared for the example of a tractor roof with a gel-coated surface. Consideration is given to the possibility of reinforcement, number of smooth faces, condition of the gel-coated surface, reliability, and labor and workplace requirements of the three processes, and advantages of molding between the mold and a countermold in smooth faces, reliability, labor requirements, working surface and industrial hygiene are pointed out. The times and labor requirements of each step in the molding cycles are examined, and material requirements and yields, investment costs, amortization and product cost prices of the processes are compared. It is concluded that, for the specific component examined, the processes of vacuum injection and injection molding appear very interesting, with injection molding processes resulting in lower cost prices than contact molding for any production volume.

  5. C-Scan Performance Test of Under-Sodium ultrasonic Waveguide Sensor in Sodium

    International Nuclear Information System (INIS)

    Joo, Young Sang; Bae, Jin Ho; Kim, Jong Bum

    2011-01-01

    Reactor core and in-vessel structures of a sodium-cooled fast (SFR) are submerged in opaque liquid sodium in the reactor vessel. The ultrasonic inspection techniques should be applied for observing the in-vessel structures under hot liquid sodium. Ultrasonic sensors such as immersion sensors and rod-type waveguide sensors have developed in order to apply under-sodium viewing of the in-vessel structures of SFR. Recently the novel plate-type ultrasonic waveguide sensor has been developed for the versatile application of under-sodium viewing in SFR. In previous studies, the ultrasonic waveguide sensor module was designed and manufactured, and the feasibility study of the ultrasonic waveguide sensor was performed. To improve the performance of the ultrasonic waveguide sensor in the under-sodium application, a new concept of ultrasonic waveguide sensors with a Be coated SS304 plate is suggested for the effective generation of a leaky wave in liquid sodium and the non-dispersive propagation of A 0 -mode Lamb wave in an ultrasonic waveguide sensor. In this study, the C-scan performance of the under-sodium ultrasonic waveguide sensor in sodium has been investigated by the experimental test in sodium. The under-sodium ultrasonic waveguide sensor and the sodium test facility with a glove box system and a sodium tank are designed and manufactured to carry out the performance test of under-sodium ultrasonic waveguide sensor in sodium environment condition

  6. Auger recombination in sodium iodide

    Science.gov (United States)

    McAllister, Andrew; Kioupakis, Emmanouil; Åberg, Daniel; Schleife, André

    2014-03-01

    Scintillators are an important tool used to detect high energy radiation - both in the interest of national security and in medicine. However, scintillator detectors currently suffer from lower energy resolutions than expected from basic counting statistics. This has been attributed to non-proportional light yield compared to incoming radiation, but the specific mechanism for this non-proportionality has not been identified. Auger recombination is a non-radiative process that could be contributing to the non-proportionality of scintillating materials. Auger recombination comes in two types - direct and phonon-assisted. We have used first-principles calculations to study Auger recombination in sodium iodide, a well characterized scintillating material. Our findings indicate that phonon-assisted Auger recombination is stronger in sodium iodide than direct Auger recombination. Computational resources provided by LLNL and NERSC. Funding provided by NA-22.

  7. Successful treatment of sodium oxalate induced urolithiasis with Helichrysum flowers.

    Science.gov (United States)

    Onaran, Metin; Orhan, Nilüfer; Farahvash, Amirali; Ekin, Hasya Nazlı; Kocabıyık, Murat; Gönül, İpek Işık; Şen, İlker; Aslan, Mustafa

    2016-06-20

    Helichrysum (Asteraceae) flowers, known as "altın otu, yayla çiçeği, kudama çiçeği" , are widely used to remove kidney stones and for their diuretic properties in Turkey. To determine the curative effect of infusions prepared from capitulums of Helichrysum graveolens (M. Bieb.) Sweet (HG) and H. stoechas ssp. barellieri (Ten.) Nyman (HS) on sodium oxalate induced kidney stones. Infusions prepared from the capitulums of HG and HS were tested for their curative effect on calcium oxalate deposition induced by sodium oxalate (70mg/kg i.p.). Following the injection of sodium oxalate for 5 days, plant extracts were administered to rats at two different doses. Potassium citrate was used as positive control. Water intake, urine volume, body, liver and kidney weights were measured; biochemical and hematological analyses were conducted on urine and blood samples. Additionally, histopathological examinations were done on kidney samples. H. stoechas extract showed prominent effect at 156mg/kg dose (stone formation score: 0.33), whereas number of kidney stones was maximum in sodium oxalate group (stone formation score: 2.33). The reduction in the uric acid and oxalate levels of urine samples and the elevation in the urine citrate levels are significant and promising in extract groups. Some hematological, biochemical and enzymatic markers are also ameliorated by the extracts. This is the first report on the curative effect of immortal flowers. Our preliminary study indicated that Helichrysum extracts may be used for treatment of urolithiasis and Helichrysum extracts are an alternative therapy to potassium citrate for patients suffering from kidney stones. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  8. Sodium vapor charge exchange cell

    International Nuclear Information System (INIS)

    Hiddleston, H.R.; Fasolo, J.A.; Minette, D.C.; Chrien, R.E.; Frederick, J.A.

    1976-01-01

    An operational sequential charge-exchange ion source yielding a 50 MeV H - current of approximately 8 mA is planned for use with the Argonne 500 MeV booster synchrotron. We report on the progress for development of a sodium vapor charge-exchange cell as part of that planned effort. Design, fabrication, and operating results to date are presented and discussed. (author)

  9. Cooling water injection system

    International Nuclear Information System (INIS)

    Inai, Nobuhiko.

    1989-01-01

    In a BWR type reactor, ECCS system is constituted as a so-called stand-by system which is not used during usual operation and there is a significant discontinuity in relation with the usual system. It is extremely important that ECCS operates upon occurrence of accidents just as specified. In view of the above in the present invention, the stand-by system is disposed along the same line with the usual system. That is, a driving water supply pump for supplying driving water to a jet pump is driven by a driving mechanism. The driving mechanism drives continuously the driving water supply pump in a case if an expected accident such as loss of the function of the water supply pump, as well as during normal operation. That is, all of the water supply pump, jet pump, driving water supply pump and driving mechanism therefor are caused to operate also during normal operation. The operation of them are not initiated upon accident. Thus, the cooling water injection system can perform at high reliability to remarkably improve the plant safety. (K.M.)

  10. Distributed temperature sensor testing in liquid sodium

    Energy Technology Data Exchange (ETDEWEB)

    Gerardi, Craig, E-mail: cgerardi@anl.gov; Bremer, Nathan; Lisowski, Darius; Lomperski, Stephen

    2017-02-15

    Highlights: • Distributed temperature sensors measured high-resolution liquid-sodium temperatures. • DTSs worked well up to 400 °C. • A single DTS simultaneously detected sodium level and temperature. - Abstract: Rayleigh-backscatter-based distributed fiber optic sensors were immersed in sodium to obtain high-resolution liquid-sodium temperature measurements. Distributed temperature sensors (DTSs) functioned well up to 400 °C in a liquid sodium environment. The DTSs measured sodium column temperature and the temperature of a complex geometrical pattern that leveraged the flexibility of fiber optics. A single Ø 360 μm OD sensor registered dozens of temperatures along a length of over one meter at 100 Hz. We also demonstrated the capability to use a single DTS to simultaneously detect thermal interfaces (e.g. sodium level) and measure temperature.

  11. Combustion suppressing device for leaked sodium

    International Nuclear Information System (INIS)

    Ooto, Akihiro.

    1985-01-01

    Purpose: To suppress the atmospheric temperature to secure the building safety and shorten the recovery time after the leakage in a chamber for containing sodium leaked from coolant circuit equipments or pipeways of LMFBR type rector by suppressing the combustion of sodium contained in the chamber. Constitution: To the inner wall of a chamber for containing sodium handling equipments, are vertically disposed a panel having a coolant supply port at the upper portion and a coolant discharge port at the lower portion thereof and defined with a coolant flowing channel and a panel for sucking the coolant discharged from the abovementioned panel and exhausting the same externally. Further, a corrugated combustion suppressing plate having apertures for draining the condensated leaked sodium is disposed near the sodium handling equipments. If ruptures are resulted to the sodium handling equipments or pipeway, leaked sodium is passed through the drain apertures in the suppressing plate and stored at the bottom of the containing chamber. (Horiuchi, T.)

  12. Development of the immersed sodium flowmeter

    International Nuclear Information System (INIS)

    Chen Daolong

    1994-09-01

    An immersed sodium flowmeter of the range 3 m 3 /h is developed. It is a flowmeter of entire-sealed construction, it can be operated in sodium. Its construction, the theoretical calculation of the calibration characteristic and the pressure loss, the test facility and the calibration test are presented in detail. It analytical expression of the calibration characteristic in the temperature limit 200∼600 degree C and the error analysis are given. The basic error of this immersed sodium flowmeter is below +-2.3% of the measuring range. The immersed sodium flowmeter can be used to resolve the sodium flowrate measuring problems of the in-reactor component of LMFBR, for example, the flowrate measuring of the in-reactor sodium purification loop, the flowrate measuring of the immersed sodium pump and the flowrate measuring of the in-reactor test component

  13. Sodium bicarbonate improves swimming performance.

    Science.gov (United States)

    Lindh, A M; Peyrebrune, M C; Ingham, S A; Bailey, D M; Folland, J P

    2008-06-01

    Sodium bicarbonate ingestion has been shown to improve performance in single-bout, high intensity events, probably due to an increase in buffering capacity, but its influence on single-bout swimming performance has not been investigated. The effects of sodium bicarbonate supplementation on 200 m freestyle swimming performance were investigated in elite male competitors. Following a randomised, double blind counterbalanced design, 9 swimmers completed maximal effort swims on 3 separate occasions: a control trial (C); after ingestion of sodium bicarbonate (SB: NaHCO3 300 mg . kg (-1) body mass); and after ingestion of a placebo (P: CaCO3 200 mg . kg (-1) body mass). The SB and P agents were packed in gelatine capsules and ingested 90 - 60 min prior to each 200 m swim. Mean 200 m performance times were significantly faster for SB than C or P (1 : 52.2 +/- 4.7; 1 : 53.7 +/- 3.8; 1 : 54.0 +/- 3.6 min : ss; p bicarbonate were all elevated pre-exercise in the SB compared to C and P trials (p < 0.05). Post-200 m blood lactate concentrations were significantly higher following the SB trial compared with P and C (p < 0.05). It was concluded that SB supplementation can improve 200 m freestyle performance time in elite male competitors, most likely by increasing buffering capacity.

  14. Sodium fires in nuclear facilities

    International Nuclear Information System (INIS)

    Menzenhauer, P.

    1974-01-01

    The work deals with the behaviour of liquid sodium when it comes into contact with air, especially in the course of fires in technical plants. The most important fire procedures are constructed as realistically as possible, that is to say that the fires were not only carried out on a laboratory scale but with quantities of up to 200 kg sodium at temperatures of up to 800 0 C. The following was investigated: 1) the course of the fire in rooms, 2) restriction of the fire, 3) removal of the burnt remains, 4) protection measures. The fire was varied in its most important physical appearance such as surface fire, spurt fire and fire on isolated pipe lines. The fires were checked by precautionary, contructive measures - it was not necessary to place persons at the site of the fire - and by active measures such as for example by covering with extinguishing powder. All important test phases were captured in film and slides series. Visible material is thus available for the operation team of sodium plants and fire brigades who might possibly be called upon. (orig./LH) [de

  15. A study of atomic interaction between suspended nanoparticles and sodium atoms in liquid sodium

    International Nuclear Information System (INIS)

    Saito, Jun-ichi; Ara, Kuniaki

    2010-01-01

    A feasibility study of suppression of the chemical reactivity of sodium itself using an atomic interaction between nanoparticles and sodium atoms has been carried out. We expected that the atomic interaction strengthens when the nanoparticle metal is the transition element which has a major difference in electronegativity from sodium. We also calculated the atomic interaction between nanoparticle and sodium atoms. It became clear that the atomic bond between the nanoparticle atom and the sodium atom is larger than that between sodium atoms, and the charge transfer takes place to the nanoparticle atom from the sodium atom. Using sodium with suspended nanoparticles, the fundamental physical properties related to the atomic interaction were investigated to verify the atomic bond. The surface tension of sodium with suspended nanoparticles increased, and the evaporation rate of sodium with suspended nanoparticles also decreased compared with that of sodium. Therefore the presence of the atomic interaction between nanoparticles and sodium was verified from these experiments. Because the fundamental physical property changes by the atomic interaction, we expected changes in the chemical reactivity characteristics. The chemical reaction properties of sodium with suspended nanoparticles with water were investigated experimentally. The released reaction heat and the reaction rate of sodium with suspended nanoparticles were reduced than those of sodium. The influence of the charge state of nanoparticle on the chemical process with water was theoretically investigated to speculate on the cause of reaction suppression. The potential energy in both primary and side reactions changed by the charge transfer, and the free energy of activation of the reaction with water increased. Accordingly, the reaction barrier also increased. This suggests there is a possibility of the reduction in the reaction of sodium by the suspension of nanoparticles. Consequently the possibility of the

  16. Sodium setpoint and gradient in bicarbonate hemodialysis.

    Science.gov (United States)

    Basile, Carlo; Libutti, Pasquale; Lisi, Piero; Vernaglione, Luigi; Casucci, Francesco; Losurdo, Nicola; Teutonico, Annalisa; Lomonte, Carlo

    2013-01-01

    The demonstration of an individual osmolar setpoint in hemodialysis (HD) is crucial to individualize dialysate sodium concentrations. Furthermore, the diffusive gradient between plasma and dialysate sodium is important in the "fine tuning" of the intradialytic sodium mass balance (MB). The design of this study included part A: a retrospective analysis of predialysis plasma sodium concentrations extracted from a 6-year database in our HD population (147 prevalent white anuric patients); and part B: study of intradialytic sodium kinetics in 48 patients undergoing one 4-hour bicarbonate HD session. Direct potentiometry with an ion-selective electrode was used for sodium measurements. Study part A: the mean number of plasma sodium measurements per patient was 16.06 ± 14.03 over a mean follow-up of 3.55 ± 1.76 years. The mean of the averaged plasma sodium concentrations was 136.7 ± 2.1 mmol/L, with a low mean intraindividual coefficient of variation (1.39 ± 0.4). Study part B: mean predialysis and postdialysis plasma sodium concentrations were 135.8 ± 0.9 and 138.0 ± 0.9 mmol/L (p<0.001). Mean inlet dialyzer sodium concentration was 138.7 ± 1.1 mmol/L; the hourly diffusion concentration gradients showed a statistically significant transfer from dialysate to plasma (Wilks ? <0.0001). A statistically significant relationship was found between sodium MB and diffusion gradient (p<0.02), and between sodium MB and ultrafiltration volume (p<0.01). A relatively "fixed" and individual osmolar setpoint in HD patients was shown for the first time in a long-term follow-up. A dialysate sodium concentration of 140 mmol/L determined a dialysate to plasma sodium gradient.

  17. Intelligent type sodium instrumentations for LMFR

    International Nuclear Information System (INIS)

    Daolong Chen

    1996-01-01

    The constructions and their performances of a lot of newly developed intelligent type sodium instrumentations that consist of the intelligent type sodium flowmeter, the intelligent type immersed sodium flowmeter, the intelligent type sodium manometer and the intelligent type sodium level gauge are described. The graduation characteristic equations for corresponding transducer using the medium temperature as the parameter are given. Because the operating temperature limit of measured medium (sodium) is wide, so the on-line compensation of the temperature effect of their graduation characteristics much be considered. The tests show that these intelligent type sodium instrumentations possess of good linearity. The accurate sodium process parameter (flowrate, pressure and level) measurement data can be obtained by means of their on-line compensation function of the temperature effect. Moreover, these intelligent type sodium instrumentations possess of the self-inspection, the electric shutoff protection, the setting of full-scale, the setting of alarm limits (two upper limits and two lower limits alarms), the thermocouple breaking alarm, each other isolative the 0-10V direct-current analogue output and CENTRONICS standard digital output, and the alarm relay contact output. These intelligent type sodium instrumentations are suitable particularly for the instrument, control and protective systems of LMFR by means of these excellent functions based on microprocessor. The basic error of the intelligent type sodium flowmeter, immersed sodium flowmeter, sodium manometer and sodium level gauge is respectively ±2%, ±2.3%, ±0.3% and ±1.9% of measuring range. (author). 4 refs, 9 figs

  18. H- charge exchange injection systems

    International Nuclear Information System (INIS)

    Ankenbrandt, C.; Curtis, C.; Hojvat, C.; Johnson, R.P.; Owen, C.; Schmidt, C.; Teng, L.; Webber, R.C.

    1980-01-01

    The techniques and components required for injection of protons into cyclic accelerators by means of H - charge exchange processes are reviewed, with emphasis on the experience at Fermilab. The advantages of the technique are described. The design and performance of the system of injection of H - ions into the Fermilab Booster are detailed. (Auth.)

  19. Injection and lessons for 2012

    International Nuclear Information System (INIS)

    Bracco, C.; Barnes, M.J.; Bartmann, W.; Cornelis, K.; Drosdal, L.N.; Goddard, B.; Kain, V.; Meddahi, M.; Mertens, V.; Uythoven, J.

    2012-01-01

    Injection of 144 bunches into the LHC became fully operational during the 2011 run and one nominal injection of 288 bunches was accomplished. Several mitigation solutions were put in place to minimise losses from the Transfer Line (TL) collimators and losses from kicking de-bunched beam during injection. Nevertheless, shot-by- shot and bunch-by-bunch trajectory variations, as well as long terms drifts, were observed and required a regular re-steering of the TL implying a non negligible amount of time spent for injection setup. Likely sources of instability have been identified (i.e. MKE and MSE ripples) and possible cures to optimise 2012 operation are presented. Well defined references for TL steering will be defined in a more rigorous way in order to allow a more straightforward and faster injection setup. Encountered and potential issues of the injection system, in particular the injection kickers MKI, are discussed also in view of injections with a higher number of bunches. (authors)

  20. Injection and lessons for 2012

    CERN Document Server

    Bracco, C; Bartmann, W; Cornelis, K; Drosdal, L N; Goddard, B; Kain, V; Meddahi, M; Mertens, V; Uythoven, J

    2012-01-01

    Injection of 144 bunches into the LHC became fully operational during the 2011 run and a nominal injection of 288 bunches was accomplished during MD time. Several mitigation solutions were put in place to minimise losses from the transfer line (TL) collimators and losses from kicking debunched beam during injection. Nevertheless, shot-by-shot and bunch-by-bunch trajectory variations, as well as long terms drifts, were observed and required a regular resteering of the TL implying a non negligible amount of time spent for injection setup. Likely sources of instability have been identified (i.e. MKE and MSE ripples) and possible cures to optimise 2012 operation are presented. Well defined references for TL steering will be defined in a more rigorous way in order to allow a more straightforward and faster injection setup. Encountered and potential issues of the injection system, in particular the injection kickers MKI, are discussed also in view of injections with a higher number of bunches.

  1. Towards spin injection into silicon

    Energy Technology Data Exchange (ETDEWEB)

    Dash, S.P.

    2007-08-15

    Si has been studied for the purpose of spin injection extensively in this thesis. Three different concepts for spin injection into Si have been addressed: (1) spin injection through a ferromagnet-Si Schottky contact, (2) spin injection using MgO tunnel barriers in between the ferromagnet and Si, and (3) spin injection from Mn-doped Si (DMS) as spin aligner. (1) FM-Si Schottky contact for spin injection: To be able to improve the interface qualities one needs to understand the atomic processes involved in the formation of silicide phases. In order to obtain more detailed insight into the formation of such phases the initial stages of growth of Co and Fe were studied in situ by HRBS with monolayer depth resolution.(2) MgO tunnel barrier for spin injection into Si: The fabrication and characterization of ultra-thin crystalline MgO tunnel barriers on Si (100) was presented. (3) Mn doped Si for spin injection: Si-based diluted magnetic semiconductor samples were prepared by doping Si with Mn by two different methods i) by Mn ion implantation and ii) by in-diffusion of Mn atoms (solid state growth). (orig.)

  2. Instrumentation for Sodium Circuits; Instrumentation des Circuits de Sodium

    Energy Technology Data Exchange (ETDEWEB)

    Cambillard, E. [CEA, Centre d' Etudes Nucleaires de Fontenay-aux-Roses (France); Lions, N. [CEA, Centre d' Etudes Nucleaires de Cadarache (France)

    1967-06-15

    Electromagnetic flow meters, level gauges and differential pressure gauges are among the main measurement instruments designed and tested at the Commissariat a l'Energie Atomique (CEA) for sodium reactors. The main characteristics of the flow meters used with RAPSODIE are indicated. The instruments used in this connection are of the permanent -magnet or electromagnet type (in the primary circuits). A description is given of the calibration methods employed - use is made of diaphragms or Venturi tubes as standard flow meters - and information is given on the results measured for maximum sodium flows of 400 m{sup 3}/h. Three types of continuous level gauge have been studied. Resistance gauge. Two varieties used for the 1 - and 10-MW test circuits of RAPSODIE are described. In one there is a compensation resistance along the whole height of the measuring element (the continuous gauges used with the RAPSODIE reactor are at present of this type). In the other type of gauge a device is incorporated to heat the measurement element and prevent the formation of conducting deposits (prototype sodium tests have been completed). Induction gauge. This type has two coupled coils and is fitted with a device to compensate for temperature effects. A description is given of a prototype which has been built and the results obtained in the course of sodium tests are described. Ultrasonic gauge. With this type, a transmitter is fitted on top of the outside of the sodium container; there is also a vertical wave guide, the bottom of which is immersed in the liquid metal and possesses a reflector system which returns the ultrasonic beam towards the surface. Fixed reference marks provide a permanent means of calibration and the whole apparatus is welded. This type of gauge is now being constructed. The differential pressure gauges that have been built, and used in particular with Venturi tube flow meters, are modified versions of the devices employed with the 1 - and 10-MW test circuits of

  3. CT guided diagnostic foot injections

    International Nuclear Information System (INIS)

    Saifuddin, A.; Abdus-Samee, M.; Mann, C.; Singh, D.; Angel, J.C.

    2005-01-01

    AIM: To describe a CT technique for guiding diagnostic and therapeutic injections in the hind- and mid-foot. MATERIALS AND METHODS: Over a period of 50 months, 28 individuals were referred for diagnostic and therapeutic hind- and mid-foot injections before possible arthrodesis. A CT technique was developed that allowed entry into the various joints using a vertical approach. Numbers of joints injected were as follows: posterior subtalar, 21; talonavicular, 4; calcaneonavicular, calcaneocuboid, navicular-cuneiform and 5th metatarsocuboid joints, 1 each. RESULTS: All injections but one were technically successful. Significant relief of symptoms was noted by 16 participants, whereas for 9 there was no improvement and for 3 a partial response was achieved. CONCLUSION: CT is a simple and safe alternative to fluoroscopy for guiding diagnostic and therapeutic foot injections, and may be the technique of choice in cases of disordered anatomy

  4. Analysis of acoustic data from UK sodium/water reaction test facilities

    International Nuclear Information System (INIS)

    Rowley, R.; Mcknight, J.A.; Airey, J.

    1990-01-01

    This paper describes acoustic measurements made during a number of sodium/water reaction experiments in the UK. The tests have included water and steam injections through both realistic (fatigue crack) defects and machined orifices and have covered a range of experimental conditions including those appropriate to the inlet and outlet regions of the EFR steam generators. Injection rates were typically in the range 0.1 to 30 g/s. Where possible, gas injections were also included in the test programme for comparison, since it is anticipated that a practical SGU acoustic leak detection system would include a facility for gas injections to allow system calibration, and to confirm transmission properties within the SGU. The test sections were instrumented with accelerometers on waveguides and in some cases included an under-sodium microphone situated about 300mm above the reaction zone. Tape recordings were made during the tests and used for detailed analysis off-line, although an audible output from one of the acoustic channels was used to monitor the progress of the injections and provide information for the rig operators. A comparison of the signal amplitudes measured during the experiments with typical reactor background noise was made and an estimate of the detection sensitivity of an acoustic monitoring system was deduced. 3 refs, 5 figs, 1 tab

  5. A Patient with MSUD: Acute Management with Sodium Phenylacetate/Sodium Benzoate and Sodium Phenylbutyrate

    Directory of Open Access Journals (Sweden)

    Melis Köse

    2017-01-01

    Full Text Available In treatment of metabolic imbalances caused by maple syrup urine disease (MSUD, peritoneal dialysis, and hemofiltration, pharmacological treatments for elimination of toxic metabolites can be used in addition to basic dietary modifications. Therapy with sodium phenylacetate/benzoate or sodium phenylbutyrate (NaPB in urea-cycle disorder cases has been associated with a reduction in branched-chain amino acid (BCAA concentrations when the patients are on adequate dietary protein intake. Moreover, NaPB in treatment of MSUD patients is also associated with reduction of BCAA levels in a limited number of cases. However, there are not enough studies in the literature about application and efficacy of this treatment. Our case report sets an example of an alternative treatment’s efficacy when extracorporeal procedures are not available due to technical difficulties during attack period of the disease.

  6. A Patient with MSUD: Acute Management with Sodium Phenylacetate/Sodium Benzoate and Sodium Phenylbutyrate.

    Science.gov (United States)

    Köse, Melis; Canda, Ebru; Kagnici, Mehtap; Uçar, Sema Kalkan; Çoker, Mahmut

    2017-01-01

    In treatment of metabolic imbalances caused by maple syrup urine disease (MSUD), peritoneal dialysis, and hemofiltration, pharmacological treatments for elimination of toxic metabolites can be used in addition to basic dietary modifications. Therapy with sodium phenylacetate/benzoate or sodium phenylbutyrate (NaPB) in urea-cycle disorder cases has been associated with a reduction in branched-chain amino acid (BCAA) concentrations when the patients are on adequate dietary protein intake. Moreover, NaPB in treatment of MSUD patients is also associated with reduction of BCAA levels in a limited number of cases. However, there are not enough studies in the literature about application and efficacy of this treatment. Our case report sets an example of an alternative treatment's efficacy when extracorporeal procedures are not available due to technical difficulties during attack period of the disease.

  7. Sodium vapor deposition onto a horizontal flat plate above liquid sodium surface, (3)

    International Nuclear Information System (INIS)

    Kudo, Kazuhiko; Hirata, Masaru.

    1978-01-01

    Sodium vapour and sodium mist in the cover gas of a sodium system of a fast breeder reactor cause various problems. In this report, with the results of measurements of sodium mist concentration, the distribution of sodium mist diameter in cover gas was analytically obtained. The analysis was made by using the different nucleus model B. The measurement of the concentration of sodium mist was carried out with a sodium mist pot designed by the author. The experiment was done at the sodium temperature of 400 and 500 degree centigrade. The relations among sodium temperature, upper wall temperature, and the sodium mist concentration in cover gas were obtained. Evaluation of effective condensed nuclear radius in the cover gas was made by the comparison of analysis and experimental results. The results of this evaluation shows the following conclusions. It is impossible to express the distribution of sodium mist diameter by normal distribution or logarithmic normal distribution. Drop of sodium temperature results in the decrease of weight mean radius of generated sodium mist. Drop of upper wall temperature causes the decrease of weight mean radius, and increases sodium mist concentration. (Kato, T.)

  8. Compressed air injection technique to standardize block injection pressures.

    Science.gov (United States)

    Tsui, Ban C H; Li, Lisa X Y; Pillay, Jennifer J

    2006-11-01

    Presently, no standardized technique exists to monitor injection pressures during peripheral nerve blocks. Our objective was to determine if a compressed air injection technique, using an in vitro model based on Boyle's law and typical regional anesthesia equipment, could consistently maintain injection pressures below a 1293 mmHg level associated with clinically significant nerve injury. Injection pressures for 20 and 30 mL syringes with various needle sizes (18G, 20G, 21G, 22G, and 24G) were measured in a closed system. A set volume of air was aspirated into a saline-filled syringe and then compressed and maintained at various percentages while pressure was measured. The needle was inserted into the injection port of a pressure sensor, which had attached extension tubing with an injection plug clamped "off". Using linear regression with all data points, the pressure value and 99% confidence interval (CI) at 50% air compression was estimated. The linearity of Boyle's law was demonstrated with a high correlation, r = 0.99, and a slope of 0.984 (99% CI: 0.967-1.001). The net pressure generated at 50% compression was estimated as 744.8 mmHg, with the 99% CI between 729.6 and 760.0 mmHg. The various syringe/needle combinations had similar results. By creating and maintaining syringe air compression at 50% or less, injection pressures will be substantially below the 1293 mmHg threshold considered to be an associated risk factor for clinically significant nerve injury. This technique may allow simple, real-time and objective monitoring during local anesthetic injections while inherently reducing injection speed.

  9. Conclusive experimental study of prevention measures against sodium combustion residuum reignition. Run-F9-1, Run-F9-2

    International Nuclear Information System (INIS)

    Ishikawa, Hiroyasu; Ohno, Shuji; Miyahara, Shinya

    2004-04-01

    Nitrogen gas can be an extinguisher or a mitigating material in the case of sodium leak and fire accident in an air atmosphere, which may occur at a liquid metal cooled nuclear power plant. However, sodium combustion residuum sometimes reignites in the air atmosphere even at room temperature when it was produced by nitrogen gas injection to the burning sodium. Then, in this study we executed conclusive experiments of prevention measures against sodium combustion residuum reignition by a mixture of carbon-dioxide (CO 2 ) gas, humidity and nitrogen gas. The experiments were carried out with the FRAT-1 test equipment; the humidity conditions were changed in air which were used to sodium combustion atmosphere and exposure air for confirmation of prevented combustion residue reignition. First of all, the sodium of about 2.5 kg was leaked in air atmosphere, and next, the sodium combustion was stopped by nitrogen gas injection. Next, the combustion residuum was cooled in the nitrogen atmosphere, and then the combustion residuum was exposed to atmosphere of carbon-dioxide (4%); humidity (6000vppm); oxygen (3%)-nitrogen (based gas) mixture. It was confirmed that the combustion residuum was not reignition even if exposed to the air atmosphere again at the end of experiment. We had confirmed that the prevention measures against sodium combustion residuum reignition to establish by this research were effective. (author)

  10. Diazepam reduces excitability of amygdala and further influences auditory cortex following sodium salicylate treatment in rats.

    Science.gov (United States)

    Song, Yu; Liu, Junxiu; Ma, Furong; Mao, Lanqun

    2016-12-01

    Diazepam can reduce the excitability of lateral amygdala and eventually suppress the excitability of the auditory cortex in rats following salicylate treatment, indicating the regulating effect of lateral amygdala to the auditory cortex in the tinnitus procedure. To study the spontaneous firing rates (SFR) of the auditory cortex and lateral amygdala regulated by diazepam in the tinnitus rat model induced by sodium salicylate. This study first created a tinnitus rat modal induced by sodium salicylate, and recorded SFR of both auditory cortex and lateral amygdala. Then diazepam was intraperitoneally injected and the SFR changes of lateral amygdala recorded. Finally, diazepam was microinjected on lateral amygdala and the SFR changes of the auditory cortex recorded. Both SFRs of the auditory cortex and lateral amygdala increased after salicylate treatment. SFR of lateral amygdala decreased after intraperitoneal injection of diazepam. Microinjecting diazepam to lateral amygdala decreased SFR of the auditory cortex ipsilaterally and contralaterally.

  11. Optimization of injection law for direct injection diesel engine

    International Nuclear Information System (INIS)

    Feola, M.; Bella, G.; Pelloni, P.; Casoli, P.; Toderi, G.; Cantore, G.

    1992-01-01

    This paper describes how different timing and shape of the injection law can influence pollutant emission of a direct injection diesel engine. The study was carried out making use of a multizone thermodynamic model as regards the closed valve phase, and a filling-emptying one as regards the open valve phase. After being calibrated by comparison with experimental data, the abovementioned model was used for injection law optimization as regards minimum pollutant concentration (NO x and soot) in the exhaust gases with the smallest engine performance reduction possible

  12. Action of neuro-hypophysis hormones on sodium exchanges of Carassius auratus L; Action des hormones neurohypophysaires sur les echanges de sodium de Carassius auratus L.

    Energy Technology Data Exchange (ETDEWEB)

    Julien, Monique

    1960-06-25

    This academic work reports the use of radio-sodium as indicator of sodium exchanges to simultaneously measure the gill input flow and the output gill and urinary flows. This technique has been applied in the case of a common soft water fish (Carassius auratus L.) to study the possible action of neuro-hypophysis extracts on these flows, and the action of these hormones on urinary excretion [French] Nous avons mesure les echanges de sodium de Carassius auratus a l'aide de radiosodium 24. L'action d'extraits neuro-hypophysaires d'origine diverse a ete comparee a celle d'injection temoin de chlorure de sodium isotonique, aussi bien sur les flux d'entree et de sortie de sodium que sur l'excretion urinaire. De ces experiences faites in vivo, nous pouvons tirer les conclusions suivantes: 1 - L'extrait neurohypophysaire de Carassius auratus provoque une augmentation du flux d'entree de sodium au niveau de la branchie de cet animal alors que le flux de sortie reste inchange. Cet extrait semble plus actif qu'une dose d'ocytocine egale a son activite ocytocique propre. Parmi les hormones neurohypophysaires de mammiferes, seule l'ocytocine (a forte dose) produit une action analogue a celle decrite ci-dessus. L'extrait de Rana esculenta reste sans action. Nous en avons conclu a l'existence dans la neurohypophyse de Carassius auratus d'un facteur hormonal agissant au niveau de la branchie pour controler l'osmoregulation de ce poisson. 2 - Les extraits neurohypophysaires de Carassius auratus entrainent chez l'animal une augmentation de la diurese et de la concentration de sodium de l'urine. Cependant cette action reste discrete et fugace. Les hormones de mammiferes, et les extraits neurohypophysaires d'amphibiens restent sans action. 3 - D'autres auteurs ont montre que chez les amphibiens, l'action des hormones neurohypophysaires se traduit a la fois par une augmentation du transport actif de sodium a travers la peau et par un desequilibre de la balance hydrique (augmentation du

  13. Sodium-sodium intermediate heat exchangers design problems

    International Nuclear Information System (INIS)

    Chandramohan, R.

    1975-01-01

    This paper deals briefly with the calculation methods adapted, in working-out the stresses due to fluid pressures (normal as well as transient), weights, piping-reactions, vibration in the tube-bundle and also the thermal stresses during normal and transient conditions, for the mechanical design of intermediate heat-exchanger. The thermal stress evaluation of the tube-sheet is given particular emphasis. A brief outline of the design problems connected with the Na-Na exchangers of large size sodium cooled fast reactor plants is also given. (author)

  14. Cleaning of Sodium in the Cold Trap

    International Nuclear Information System (INIS)

    Kim, Byung Ho; Jeong, Ji Young; Kim, Jong Man; Choi, Byung Hae; Nam, Ho Yun

    2005-01-01

    The purpose of a cleaning process is to remove the residual sodium adhering to the component walls once it has been properly drained. It is necessary to clean and decontaminate a component, especially the large components of the primary coolant system; such as the intermediate heat exchangers and the primary pump. Improper and inadequate cleaning has in a number of cases resulted in problems in the storage, handling, and reuse of components. Several types of failures due to improper cleaning procedures have been defined in the past. Inadequate and incomplete removal of sodium results in residues which may contain metallic sodium and alkaline compounds such as sodium hydroxide, sodium oxide, sodium carbonate, and various types of alcoholates. Reinsertion of components containing these compounds into a high-temperature sodium system can result in either the intergranular penetration characteristic of a high- oxygen sodium or an accelerated corrosion due to oxygen. The methods used for cleaning sodium equipment depend on the condition and types of equipment to be cleaned and whether the equipment is to be reused. Cleaning methods are needed that will avoid a deleterious local overheating, material surface degradation or deposits, chemical, physical, or mechanical damage, and external effects. This paper discusses a steam-nitrogen gas cleaning method for the routine applications that permits the reuse of the cold trap in sodium

  15. Wireless sensor network for sodium leak detection

    International Nuclear Information System (INIS)

    Satya Murty, S.A.V.; Raj, Baldev; Sivalingam, Krishna M.; Ebenezer, Jemimah; Chandran, T.; Shanmugavel, M.; Rajan, K.K.

    2012-01-01

    Highlights: ► Early detection of sodium leak is mandatory in any reactor handling liquid sodium. ► Wireless sensor networking technology has been introduced for detecting sodium leak. ► We designed and developed a wireless sensor node in-house. ► We deployed a pilot wireless sensor network for handling nine sodium leak signals. - Abstract: To study the mechanical properties of Prototype Fast Breeder Reactor component materials under the influence of sodium, the IN Sodium Test (INSOT) facility has been erected and commissioned at Indira Gandhi Centre for Atomic Research. Sodium reacts violently with air/moisture leading to fire. Hence early detection of sodium leak if any is mandatory for such plants and almost 140 sodium leak detectors are placed throughout the loop. All these detectors are wired to the control room for data collection and monitoring. To reduce the cost, space and maintenance that are involved in cabling, the wireless sensor networking technology has been introduced in the sodium leak detection system of INSOT. This paper describes about the deployment details of the pilot wireless sensor network and the measures taken for the successful deployment.

  16. Containment Sodium Chemistry Models in MELCOR.

    Energy Technology Data Exchange (ETDEWEB)

    Louie, David [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Humphries, Larry L. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Denman, Matthew R [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2017-04-01

    To meet regulatory needs for sodium fast reactors’ future development, including licensing requirements, Sandia National Laboratories is modernizing MELCOR, a severe accident analysis computer code developed for the U.S. Nuclear Regulatory Commission (NRC). Specifically, Sandia is modernizing MELCOR to include the capability to model sodium reactors. However, Sandia’s modernization effort primarily focuses on the containment response aspects of the sodium reactor accidents. Sandia began modernizing MELCOR in 2013 to allow a sodium coolant, rather than water, for conventional light water reactors. In the past three years, Sandia has been implementing the sodium chemistry containment models in CONTAIN-LMR, a legacy NRC code, into MELCOR. These chemistry models include spray fire, pool fire and atmosphere chemistry models. Only the first two chemistry models have been implemented though it is intended to implement all these models into MELCOR. A new package called “NAC” has been created to manage the sodium chemistry model more efficiently. In 2017 Sandia began validating the implemented models in MELCOR by simulating available experiments. The CONTAIN-LMR sodium models include sodium atmosphere chemistry and sodium-concrete interaction models. This paper presents sodium property models, the implemented models, implementation issues, and a path towards validation against existing experimental data.

  17. Injection, injectivity and injectability in geothermal operations: problems and possible solutions. Phase I. Definition of the problems

    Energy Technology Data Exchange (ETDEWEB)

    Vetter, O.J.; Crichlow, H.B.

    1979-02-14

    The following topics are covered: thermodynamic instability of brine, injectivity loss during regular production and injection operations, injectivity loss caused by measures other than regular operations, heat mining and associated reservoir problems in reinjection, pressure maintenance through imported make-up water, suggested solutions to injection problems, and suggested solutions to injection problems: remedial and stimulation measures. (MHR)

  18. The Initial Comparison Study of Sodium Lignosulfonate, Sodium Dodecyl Benzene Sulfonate, and Sodium p-Toluene Sulfonate Surfactant for Enhanced Oil Recovery

    Science.gov (United States)

    Khoirul Anas, Argo; Iman Prakoso, Nurcahyo; Sasvita, Dilla

    2018-04-01

    Surfactant (surface active agent) exhibit numerous interesting properties that enable their use as additional component in mobilising of residual oil from capillary pore after secondary recovery process using gas injection and water flooding. In this study, Sodium Lignosulfonate (SLS) surfactant was successfully synthesized by applying batch method using lignin from oil palm empty fruit bunches as precursor. Furthermore, its performance in reducing interfacial tension of crude oil and formation water colloidal system was compared with commercial available surfactant including Sodium Dodecyl Benzene Sulfonate (SDBS) and Sodium p-Toluene Sulfonate (SpTS). The synthesized SLS surfactant was characterized by using Fourier Transform Infrared (FTIR) spectroscopy. Meanwhile, its performance in reducing interfacial tension of crude oil and formation water colloidal system was analyzed by using compatibility test, phase behaviour analysis, and interfacial tension (IFT) measurement. The compatibility test shows that SLS, SDBS, and SpTS surfactants were compatible with formation water. In addition, the phase behaviour analysis shows that SLS surfactant was better than SpTS surfactant, while SDBS surfactant generates the highest performance proved by the best microemulsion formation resulted by SDBS. Furthermore, the optimum concentration of SLS, SDBS, and SpTS surfactants in reducing the interfacial tension of crude oil and formation water was 1.0%. The IFT measurement indicates that the performance of SLS with the value of 1.67 mN/m was also better than SpTS surfactant with the value of 3.59 mN/m. Meanwhile, SDBS surfactant shows the best performance with the IFT value of 0.47 mN/m.

  19. Sodium appetite elicited by low-sodium diet is dependent on p44/42 mitogen-activated protein kinase (extracellular signal-regulated kinase 1/2) activation in the brain.

    Science.gov (United States)

    Monteiro, L R N; Marangon, P B; Elias, L L K; Reis, L C; Antunes-Rodrigues, J; Mecawi, A S

    2017-09-01

    Sodium appetite is regulated by several signalling molecules, among which angiotensin II (Ang II) serves as a key driver of robust salt intake by binding to Ang II type 1 receptors (AT1R) in several regions in the brain. The activation of these receptors recruits the mitogen-activated protein kinase (MAPK) pathway, which has previously been linked to Ang II-induced increases in sodium appetite. Thus, we addressed the involvement of MAPK signalling in the induction of sodium appetite after 4 days of low-sodium diet consumption. An increase in extracellular signal-regulated kinase (ERK) phosphorylation in the laminae terminalis and mediobasal hypothalamus was observed after low-sodium diet consumption. This response was reduced by i.c.v. microinjection of an AT1R antagonist into the laminae terminalis but not the hypothalamus. This result indicates that low-sodium diet consumption activates the MAPK pathway via Ang II/AT1R signalling on the laminae terminalis. On the other hand, activation of the MAPK pathway in the mediobasal hypothalamus after low-sodium diet consumption appears to involve another extracellular mediator. We also evaluated whether a low-sodium diet could increase the sensitivity for Ang II in the brain and activate the MAPK pathway. However, i.c.v. injection of Ang II increased ERK phosphorylation on the laminae terminalis and mediobasal hypothalamus; this increase achieved a response magnitude similar to those observed in both the normal and low-sodium diet groups. These data indicate that low-sodium diet consumption for 4 days is insufficient to change the ERK phosphorylation response to Ang II in the brain. To investigate whether the MAPK pathway is involved in sodium appetite after low-sodium diet consumption, we performed i.c.v. microinjections of a MAPK pathway inhibitor (PD98059). PD98059 inhibited both saline and water intake after low-sodium diet consumption. Thus, the MAPK pathway is involved in promoting the sodium appetite after low-sodium

  20. Caffeine Sodium Benzoate for Electroconvulsive Therapy Augmentation.

    Science.gov (United States)

    Bozymski, Kevin M; Potter, Teresa G; Venkatachalam, Vasu; Pandurangi, Ananda K; Crouse, Ericka L

    2018-05-15

    Because of an ongoing manufacturer shortage of injectable caffeine sodium benzoate (CSB), patients at our health system were given CSB compounded in-house to increase seizure response during electroconvulsive therapy (ECT). Therefore, we aimed to evaluate its effectiveness and safety as an ECT augmentation agent. Medical records of patients who received compounded CSB at Virginia Commonwealth University Health System were reviewed to identify adults receiving it as part of an index ECT treatment course between June 2012 and December 2016. The primary outcome was change in electroencephalogram seizure duration from pre-caffeine session to initial caffeine session. Data were also collected on demographics, motor seizure duration, maximum heart rate, mean arterial pressure, and concurrent medication use for these sessions and the last caffeine session. Seven-one patients were included in the study, predominantly white females with a mean age of 58.6 years. The most common indication for ECT was major depressive disorder resistant to pharmacotherapy (71.8%), followed by catatonia associated with another mental disorder (19.7%). Electroencephalogram seizure duration increased by 24.1 seconds on average with first CSB use (P < 0.0001), allowing 24 more patients overall to achieve goal of at least 30 seconds (P < 0.0001). No clinically significant changes in maximum heart rate or mean arterial pressure were observed, nor did any patients require an abortive agent for prolonged seizure. Five patients (7%) discontinued CSB prematurely: 4 related to adverse effects and 1 secondary to ineffectiveness. We confirm results of prior studies of the utility of CSB and add that compounded CSB is effective for ECT augmentation, maintaining effectiveness throughout the index course with minimal safety concerns.

  1. Endocrine control of active sodium transport across frog skin; Le controle endocrinien du transport actif de sodium a travers la peau de grenouille

    Energy Technology Data Exchange (ETDEWEB)

    Maetz, J. [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires

    1959-07-01

    I. Action of the neurohypophyseal peptides on sodium transport. 1) On Rana Esculenta, oxytocin alone is active on the sodium transport (not vaso pressin). 2) The post hypophysis of R.e. contains an hormonal factor even more specific on Na transport (12 times more active than oxytocin). 3) This new factor must be closely related to oxytocin. II. Action of the adrenal corticoids. 1) The skin of frogs adapted to a salt-rich external medium, shows a considerable diminution in sodium uptake. 2) This decreased sodium uptake is brought back to normal by the injections of aldosterone. 3) This suggests that salt loading of amphibians (as well as mammals) inhibits the mineralocorticoid activity of the adrenals. (author) [French] I. Action des peptides neurohypophysaires chez Rana esculenta. 1) Le transport actif de Na est sensible a l'action de l'ocytocine mais non a l'hormone antidiuretique. 2) La posthypophyse de ces grenouilles contient un facteur plus specifique encore, puisque 12 fois plus actif que l'ocytocine. 3) Ce facteur est cependant tres voisin de l'ocytocine au point de vue chimique. lI. Action des corticoides surrenaliens chez Rana Esculenta. 1) L'adaptation des grenouilles a un milieu riche en sel a pour effet une diminution considerable du transport actif de sodium, visible in vivo et in vitro. 2) L'injection d'aldosterone a des grenouilles adaptees dans ces conditions restaure le transport actif a un niveau comparable a celui que l'on observe chez les animaux conserves dans de l'eau courante. 3) Ces faits suggerent que la surcharge en NaCI produirait chez les amphibiens, comme chez les mammiferes, une mise au repos de la fonction mineralotrope de la surrenale. (auteur)

  2. Endocrine control of active sodium transport across frog skin; Le controle endocrinien du transport actif de sodium a travers la peau de grenouille

    Energy Technology Data Exchange (ETDEWEB)

    Maetz, J [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires

    1959-07-01

    I. Action of the neurohypophyseal peptides on sodium transport. 1) On Rana Esculenta, oxytocin alone is active on the sodium transport (not vaso pressin). 2) The post hypophysis of R.e. contains an hormonal factor even more specific on Na transport (12 times more active than oxytocin). 3) This new factor must be closely related to oxytocin. II. Action of the adrenal corticoids. 1) The skin of frogs adapted to a salt-rich external medium, shows a considerable diminution in sodium uptake. 2) This decreased sodium uptake is brought back to normal by the injections of aldosterone. 3) This suggests that salt loading of amphibians (as well as mammals) inhibits the mineralocorticoid activity of the adrenals. (author) [French] I. Action des peptides neurohypophysaires chez Rana esculenta. 1) Le transport actif de Na est sensible a l'action de l'ocytocine mais non a l'hormone antidiuretique. 2) La posthypophyse de ces grenouilles contient un facteur plus specifique encore, puisque 12 fois plus actif que l'ocytocine. 3) Ce facteur est cependant tres voisin de l'ocytocine au point de vue chimique. lI. Action des corticoides surrenaliens chez Rana Esculenta. 1) L'adaptation des grenouilles a un milieu riche en sel a pour effet une diminution considerable du transport actif de sodium, visible in vivo et in vitro. 2) L'injection d'aldosterone a des grenouilles adaptees dans ces conditions restaure le transport actif a un niveau comparable a celui que l'on observe chez les animaux conserves dans de l'eau courante. 3) Ces faits suggerent que la surcharge en NaCI produirait chez les amphibiens, comme chez les mammiferes, une mise au repos de la fonction mineralotrope de la surrenale. (auteur)

  3. An open-label study of sodium oxybate (Xyrem®) in spasmodic dysphonia

    Science.gov (United States)

    Rumbach, Anna F.; Blitzer, Andrew; Frucht, Steven J.; Simonyan, Kristina

    2016-01-01

    Objective Spasmodic dysphonia (SD) is a task-specific laryngeal dystonia that affects speech production. Co-occurring voice tremor (VT) often complicates the diagnosis and clinical management of SD. Treatment of SD and VT is largely limited to botulinum toxin injections into laryngeal musculature; other pharmacological options are not sufficiently developed. Study Design and Methods We conducted an open-label study in 23 SD and 22 SD/VT patients to examine the effects of sodium oxybate (Xyrem®), an oral agent with therapeutic effects similar to those of alcohol in these patients. Blinded randomized analysis of voice and speech samples assessed symptom improvement before and after drug administration. Results Sodium oxybate significantly improved voice symptoms (p = 0.001) primarily by reducing the number of SD-characteristic voice breaks and severity of VT. Sodium oxybate further showed a trend for improving VT symptoms (p = 0.03) in a subset of patients who received successful botulinum toxin injections for the management of their SD symptoms. The drug’s effects were observed approximately 30–40 min after its intake and lasted about 3.5–4 hours. Conclusion Our study demonstrated that sodium oxybate reduced voice symptoms in 82.2% of alcohol-responsive SD patients both with and without co-occurring VT. Our findings suggest that the therapeutic mechanism of sodium oxybate in SD and SD/VT may be linked to that of alcohol and as such sodium oxybate might be beneficial for alcohol-responsive SD and SD/VT patients. PMID:27808415

  4. An open-label study of sodium oxybate in Spasmodic dysphonia.

    Science.gov (United States)

    Rumbach, Anna F; Blitzer, Andrew; Frucht, Steven J; Simonyan, Kristina

    2017-06-01

    Spasmodic dysphonia (SD) is a task-specific laryngeal dystonia that affects speech production. Co-occurring voice tremor (VT) often complicates the diagnosis and clinical management of SD. Treatment of SD and VT is largely limited to botulinum toxin injections into laryngeal musculature; other pharmacological options are not sufficiently developed. Open-label study. We conducted an open-label study in 23 SD and 22 SD/VT patients to examine the effects of sodium oxybate (Xyrem), an oral agent with therapeutic effects similar to those of alcohol in these patients. Blinded randomized analysis of voice and speech samples assessed symptom improvement before and after drug administration. Sodium oxybate significantly improved voice symptoms (P = .001) primarily by reducing the number of SD-characteristic voice breaks and severity of VT. Sodium oxybate further showed a trend for improving VT symptoms (P = .03) in a subset of patients who received successful botulinum toxin injections for the management of their SD symptoms. The drug's effects were observed approximately 30 to 40 minutes after its intake and lasted about 3.5 to 4 hours. Our study demonstrated that sodium oxybate reduced voice symptoms in 82.2% of alcohol-responsive SD patients both with and without co-occurring VT. Our findings suggest that the therapeutic mechanism of sodium oxybate in SD and SD/VT may be linked to that of alcohol, and as such, sodium oxybate might be beneficial for alcohol-responsive SD and SD/VT patients. 4 Laryngoscope, 127:1402-1407, 2017. © 2016 The American Laryngological, Rhinological and Otological Society, Inc.

  5. Injection sealing of the TASS tunnel. Progress report

    International Nuclear Information System (INIS)

    Funehag, Johan

    2008-12-01

    SKB's disposal facility is planned to be located approx. 400-500 m deep and the demands of its water tightness will be very high. The plant will be located in relatively fault-free rock with limited discharge and sealing will be carried out by injection. Given the very fine cracks that need to be sealed and the strong desire to use an injection material which generate a leachate with a pH lower than 11, SKB performs studies of silica sol and cement-based mortar with low pH in order to be able to use these in the sealing works. In the sealing project a 100 m long tunnel is constructed, the TASS tunnel at a depth of 450 min at SKB's rock laboratory on Aespoe. This report includes the results obtained until September 2008. At this date the injection stages 1, 2, and half of stage 3 have been done and preparation for Stage 3 is ongoing. The tunnel has reached a length of 55.5 m and the results from leaching measurements exist for stage 2 (Section 10-34 m). Both cement-based mortar with low pH and silica sol has been used, but cement-based mortar has been used only in relatively small scale. The cement-based mortar is developed especially for the repository. Silica sol used a particle size of about 25 nm and accelerator in the form of sodium chloride. The limit for inward leakage in the tunnel is 1 l/min and 60 m tunnel. Groundwater pressure was found to be 3.0-3.5 MPa. Past results obtained from Stage 2 indicate that injection shields fulfil the rate requirement over a 23 meter distance. The control holes drilled in the screens have been used to gradually steer the injection and to demonstrate a direct sealing effect of the screens. A controllable gelation time is necessary for efficient and controllable injection. Used mixing procedure has been proven to work and intended gelation times have been achieved. The two cement-based mortar mixtures for crack injection used in the project are robust and have desirable properties. Design methodology linking borehole distance

  6. Posterior cerebral artery Wada test: sodium amytal distribution and functional deficits

    Energy Technology Data Exchange (ETDEWEB)

    Urbach, H.; Schild, H.H. [Dept. of Radiology/Neuroradiology, Univ. of Bonn (Germany); Klemm, E.; Biersack, H.J. [Bonn Univ. (Germany). Klinik fuer Nuklearmedizin; Linke, D.B.; Behrends, K.; Schramm, J. [Dept. of Neurosurgery, Univ. of Bonn (Germany)

    2001-04-01

    Inadequate sodium amytal delivery to the posterior hippocampus during the intracarotid Wada test has led to development of selective tests. Our purpose was to show the sodium amytal distribution in the posterior cerebral artery (PCA) Wada test and to relate it to functional deficits during the test. We simultaneously injected 80 mg sodium amytal and 14.8 MBq {sup 99} {sup m}Tc-hexamethylpropyleneamine oxime (HMPAO) into the P2-segment of the PCA in 14 patients with temporal lobe epilepsy. To show the skull, we injected 116 MBq {sup 99} {sup m}Tc-HDP intravenously. Sodium amytal distribution was determined by high-resolution single-photon emission computed tomography (SPECT). In all patients, HMPAO was distributed throughout the parahippocampal gyrus and hippocampus; it was also seen in the occipital lobe in all cases and in the thalamus in 11. Eleven patients were awake and cooperative; one was slightly uncooperative due to speech comprehension difficulties and perseveration. All patients showed contralateral hemianopia during the test. Four patients had nominal dysphasia for 1-3 min. None developed motor deficits or had permanent neurological deficits. Neurological deficits due to inactivation of extrahippocampal areas thus do not grossly interfere with neuropsychological testing during the test. (orig.)

  7. Worldwide Injection Technique Questionnaire Study: Population Parameters and Injection Practices.

    Science.gov (United States)

    Frid, Anders H; Hirsch, Laurence J; Menchior, Astrid R; Morel, Didier R; Strauss, Kenneth W

    2016-09-01

    From February 1, 2014, through June 30, 2015, 13,289 insulin-injecting patients from 423 centers in 42 countries took part in one of the largest surveys ever performed in diabetes. The goal was to assess patient characteristics, as well as historical and practical aspects of their injection technique. Results show that 4- and 8-mm needle lengths are each used by nearly 30% of patients and 5- and 6-mm needles each by approximately 20%. Higher consumption of insulin (as measured by total daily dose) is associated with having lipohypertrophy (LH), injecting into LH, leakage from the injection site, and failing to reconstitute cloudy insulin. Glycated hemoglobin values are, on average, 0.5% higher in patients with LH and are significantly higher with incorrect rotation of sites and with needle reuse. Glycated hemoglobin values are lower in patients who distribute their injections over larger injection areas and whose sites are inspected routinely. The frequencies of unexpected hypoglycemia and glucose variability are significantly higher in those with LH, those injecting into LH, those who incorrectly rotate sites, and those who reuse needles. Needles associated with diabetes treatment are the most commonly used medical sharps in the world. However, correct disposal of sharps after use is critically suboptimal. Many used sharps end up in public trash and constitute a major accidental needlestick risk. Use of these data should stimulate renewed interest in and commitment to optimizing injection practices in patients with diabetes. Copyright © 2016 Mayo Foundation for Medical Education and Research. Published by Elsevier Inc. All rights reserved.

  8. Injection nozzle for a turbomachine

    Science.gov (United States)

    Uhm, Jong Ho; Johnson, Thomas Edward; Kim, Kwanwoo

    2012-09-11

    A turbomachine includes a compressor, a combustor operatively connected to the compressor, an end cover mounted to the combustor, and an injection nozzle assembly operatively connected to the combustor. The injection nozzle assembly includes a first end portion that extends to a second end portion, and a plurality of tube elements provided at the second end portion. Each of the plurality of tube elements defining a fluid passage includes a body having a first end section that extends to a second end section. The second end section projects beyond the second end portion of the injection nozzle assembly.

  9. Sodium intake and dietary sources of sodium in undergraduate students from Novi Sad, Serbia

    Directory of Open Access Journals (Sweden)

    Jovičić-Bata Jelena

    2016-01-01

    Full Text Available Background/Aim. Data on sodium intake and sources of sodium in the diet in Serbia are limited. The aim of this study was to estimate the sodium intake and identify the sources of sodium in the diet of undergraduate students attending the University of Novi Sad. Methods. Students completed a questionnaire to gather data on their gender, age and university faculty attended, and then a 24 h dietary recall. The sodium intake of the students was calculated using the dietary recall data and data on the sodium content of foods. The contribution of different food groups as well as of specific foodstuffs to the total sodium intake was calculated. Results. The mean estimated sodium intake of the students was 3,938.5 ± 1,708.1 mg/day. The sodium intake of 89.1% of the surveyed students exceeded the guideline for sodium intake, the majority of the sodium coming from processed foods (78.9% of the total sodium intake. The food groups that contributed the most to the total sodium intake of the students were meat and meat products (21.7% and cereals and cereal-based products (18.6%. Bread and other bakery products were responsible for 13.1% of the total sodium intake. Conclusion. High sodium intake in students of the University of Novi Sad puts them at high risk of developing high blood pressure. The food industry should work towards reformulating products with high sodium content, especially bread and other bakery products. Efforts should be taken to reduce sodium intake among undergraduate students in Novi Sad.

  10. Improving the Corrosion Inhibitive Strength of Sodium Sulphite in Hydrogen Cyanide Solution Using Sodium Benzoate

    Directory of Open Access Journals (Sweden)

    Muhammed Olawale Hakeem AMUDA

    2008-12-01

    Full Text Available The improvement in the inhibitive strength of sodium sulphite on corrosion of mild steel in hydrogen cyanide by adding sodium benzoate in regulated volume was investigated using the fundamental weight loss measurement.500 ppm concentration inhibitive mixtures of sodium benzoate and sodium sulphite in three different volume ratios (5/15, 10/10, 15/5 were formulated and studied for corrosion rate in 200ml hydrogen cyanide fluid. Result obtained indicates that the corrosion rate of mild steel in hydrogen cyanide in the presence of sodium benzoate/sodium sulphite inhibitive mixtures range 0.322mmpy to 1.1269mmpy across the three volumetric ratios considered. The 15ml5ml sodium benzoatesodium sulphite mixture had the best average corrosion rate of 0.5123mmpy.The corrosion rate followed reducing pattern after the first 200 hours of immersion. The average corrosion rate in the sodium benzoate / sodium sulphite mixture is less than the rate in sodium sulphite and the mixture is only effective after long time exposure.It is concluded that adding sodium benzoate to sodium sulphite in the volumetric ratio 155ml improves the inhibitive strength of sodium sulphite on the corrosion of mild steel in hydrogen cyanide environment.

  11. Financial methods for waterflooding injectate design

    Science.gov (United States)

    Heneman, Helmuth J.; Brady, Patrick V.

    2017-08-08

    A method of selecting an injectate for recovering liquid hydrocarbons from a reservoir includes designing a plurality of injectates, calculating a net present value of each injectate, and selecting a candidate injectate based on the net present value. For example, the candidate injectate may be selected to maximize the net present value of a waterflooding operation.

  12. Fluoroscopically-guided foam sclerotherapy with sodium morrhuate for the treatment of lower extremity varices

    International Nuclear Information System (INIS)

    Wang Haiting; Jiang Zhongpu; Zhou Yi

    2011-01-01

    Objective: To evaluate fluoroscopically-guided foam sclerotherapy with injection of domestic sodium morrhuate in treating lower extremity varices. Methods: A total of 30 cases (39 diseased lower limbs) with lower extremity varices were enrolled in this study. Under fluoroscopic guidance foam sclerotherapy with injection of domestic sodium morrhuate was carried out in all patients. The obstructed condition of the great saphenous vein was observed during the following three months. Results: The technical success was achieved in all 39 patients. The mean dose of foam sclerosant used for each diseased limb was 5.9 ml (3.4-8.2 ml). Disappearance of blood flow reflux in lower extremity vein immediately after the treatment was seen in 35 patients (90%). Three months after the therapy, vascular sonography showed that the great saphenous vein was obstructed, and no serious complications occurred. Conclusion: For the treatment of lower extremity varices, fluoroscopically-guided foam sclerotherapy with injection of domestic sodium morrhuate is safe and effective with satisfactory results. This technique is a newly-developed micro-invasive therapy for lower extremity varices. (authors)

  13. Reduced Dietary Sodium Intake Increases Heart Rate

    DEFF Research Database (Denmark)

    Graudal, Niels A; Hubeck-Graudal, Thorbjørn; Jürgens, Gesche

    2016-01-01

    Reduced dietary sodium intake (sodium reduction) increases heart rate in some studies of animals and humans. As heart rate is independently associated with the development of heart failure and increased risk of premature death a potential increase in heart rate could be a harmful side......-effect of sodium reduction. The purpose of the present meta-analysis was to investigate the effect of sodium reduction on heart rate. Relevant studies were retrieved from an updated pool of 176 randomized controlled trials (RCTs) published in the period 1973-2014. Sixty-three of the RCTs including 72 study...... populations reported data on heart rate. In a meta-analysis of these data sodium reduction increased heart rate with 1.65 beats per minute [95% CI: 1.19, 2.11], p heart rate. This effect was independent of baseline blood pressure. In conclusion sodium reduction...

  14. Apparatus for detecting leakage of liquid sodium

    Science.gov (United States)

    Himeno, Yoshiaki

    1978-01-01

    An apparatus for detecting the leakage of liquid sodium includes a cable-like sensor adapted to be secured to a wall of piping or other equipment having sodium on the opposite side of the wall, and the sensor includes a core wire electrically connected to the wall through a leak current detector and a power source. An accidental leakage of the liquid sodium causes the corrosion of a metallic layer and an insulative layer of the sensor by products resulted from a reaction of sodium with water or oxygen in the atmospheric air so as to decrease the resistance between the core wire and the wall. Thus, the leakage is detected as an increase in the leaking electrical current. The apparatus is especially adapted for use in detecting the leakage of liquid sodium from sodium-conveying pipes or equipment in a fast breeder reactor.

  15. Influence of sodium carbonate on decomposition of formic acid by pulsed discharge plasma inside bubble in water

    Science.gov (United States)

    Iwabuchi, Masashi; Takahashi, Katsuyuki; Takaki, Koichi; Satta, Naoya

    2016-07-01

    The influence of sodium carbonate on the decomposition of formic acid by discharge inside bubbles in water was investigated experimentally. Oxygen or argon gases were injected into the water through a vertically positioned glass tube, in which the high-voltage wire electrode was placed to generate plasmas at low applied voltage. The concentration of formic acid was determined by ion chromatography. In the case of sodium carbonate additive, the pH increased owing to the decomposition of the formic acid. In the case of oxygen injection, the percentage of conversion of formic acid increased with increasing pH because the reaction rate of ozone with formic acid increased with increasing pH. In the case of argon injection, the percentage of conversion was not affected by the pH owing to the high rate loss of hydroxyl radicals.

  16. Interaction of oil and paraffin with sodium

    Energy Technology Data Exchange (ETDEWEB)

    Kozlov, F A; Zagorulko, Yu I; Kovalev, Yu P; Lamykin, E V; Alekseev, V V; Sergeev, G P [Institute of Physics and Power Engineering, Obninsk (USSR)

    1980-05-01

    This report presents the investigation results on the kinetics of a gaseous oil pyrolysis product composition change in the presence of sodium under static conditions at 350 deg. C, 550 deg. C and 700 deg. C as well as the behaviour of oil and paraffin within the sodium circulating loops. The calculated estimations of the critical oil physical state parameters in sodium flows are given. (author)

  17. Interaction of oil and paraffin with sodium

    International Nuclear Information System (INIS)

    Kozlov, F.A.; Zagorulko, Yu.I.; Kovalev, Yu.P.; Lamykin, E.V.; Alekseev, V.V.; Sergeev, G.P.

    1980-01-01

    This report presents the investigation results on the kinetics of a gaseous oil pyrolysis product composition change in the presence of sodium under static conditions at 350 deg. C, 550 deg. C and 700 deg. C as well as the behaviour of oil and paraffin within the sodium circulating loops. The calculated estimations of the critical oil physical state parameters in sodium flows are given. (author)

  18. Summary of HEDL sodium fire tests

    Energy Technology Data Exchange (ETDEWEB)

    Hilliard, R K [Hanford Engineering Development Laboratory, Richland, WA (United States)

    1979-03-01

    The sodium fire test program and related studies at the Hanford Engineering Development Laboratory (HEDL), covering the period from 1972 to 1978, are described. The program is analytical and experimental in scope, with computer code development and experimental verification. Tests have ranged in size from gram quantity laboratory tests to 1600-kg sodium spills. The experimental work is performed in two facilities: the Large Sodium Fire Facility (LSFF) and the Containment Systems Test Facility (CSTF). The facilities are described and the experimental results summarized. Sodium fire extinguishment tests which verified the Fast Flux Test Facility (FFTF) secondary sodium fire protection system are described and related information on sodium burning rates and smoke release rates are correlated. The burning rates are compared to theoretical predictions based on heat and mass transfer analogy, with good agreement. Comparisons with the SOFIRE-II code are also made. Sodium combustion aerosol properties are defined as to chemical and physical nature, settling in closed vessels and effect of added water vapor. The HAA-38 aerosol behaviour computer code is compared to tests in the 850-m{sup 3} CSTF containment vessel. Sodium spray tests in the CSTF are compared with the SPRAY computer code. An air cleaning program is described, which has the objective of removing high mass concentration sodium combustion aerosols from vented cells and containment buildings. The aerosol mass holding capacity of commercial filters was measured and an aqueous scrubber system is described. The effects of sodium spills on cell structures were investigated, including water release from heated concrete, the reaction of sodium with concrete, the formation and spontaneous recombination of hydrogen, and the ability of steel cell liners to withstand large spills of high temperature sodium without leaking. (author)

  19. Summary of HEDL sodium fire tests

    International Nuclear Information System (INIS)

    Hilliard, R.K.

    1979-01-01

    The sodium fire test program and related studies at the Hanford Engineering Development Laboratory (HEDL), covering the period from 1972 to 1978, are described. The program is analytical and experimental in scope, with computer code development and experimental verification. Tests have ranged in size from gram quantity laboratory tests to 1600-kg sodium spills. The experimental work is performed in two facilities: the Large Sodium Fire Facility (LSFF) and the Containment Systems Test Facility (CSTF). The facilities are described and the experimental results summarized. Sodium fire extinguishment tests which verified the Fast Flux Test Facility (FFTF) secondary sodium fire protection system are described and related information on sodium burning rates and smoke release rates are correlated. The burning rates are compared to theoretical predictions based on heat and mass transfer analogy, with good agreement. Comparisons with the SOFIRE-II code are also made. Sodium combustion aerosol properties are defined as to chemical and physical nature, settling in closed vessels and effect of added water vapor. The HAA-38 aerosol behaviour computer code is compared to tests in the 850-m 3 CSTF containment vessel. Sodium spray tests in the CSTF are compared with the SPRAY computer code. An air cleaning program is described, which has the objective of removing high mass concentration sodium combustion aerosols from vented cells and containment buildings. The aerosol mass holding capacity of commercial filters was measured and an aqueous scrubber system is described. The effects of sodium spills on cell structures were investigated, including water release from heated concrete, the reaction of sodium with concrete, the formation and spontaneous recombination of hydrogen, and the ability of steel cell liners to withstand large spills of high temperature sodium without leaking. (author)

  20. Summary of HEDL sodium fire tests

    International Nuclear Information System (INIS)

    Hillard, R.K.

    1978-10-01

    The sodium fire test program and related studies at the Hanford Engineering Development Laboratory (HEDL) are described. The program is analytical and experimental in scope, with computer code development and experimental verification. Tests have ranged in size from gram quantity laboratory tests to 1600-kg sodium spills. The experimental work is performed in two facilities: the Large Sodium Fire Facility (LSFF) and the Containment Systems Test Facility (CSTF). Sodium fire extinguishment tests which verified the Fast Flux Test Facility (FFTF) secondary sodium fire protection system are described and related informaion on sodium burning rates and smoke release rates are correlated. The burning rates are compared to theoretical predictions based on heat and mass transfer analogy, with good agreement. Comparisons with the SOFIRE-II code are also made. Sodium combustion aerosol properties are defined as to chemical and physical nature, settling in closed vessels and effect of added water vapor. The HAA-3B aerosol behavior computer code is compared to tests in the 850-m 3 CSTF containment vessel. Sodium spray tests in the CSTF are compared with the SPRAY computer code. An air cleaning program is described, which has the objective of removing high mass concentration sodium combustion aerosols from vented cells and containment buildings. The aerosol mass holding capacity of commercial filters was measured and an aqueous scrubber system is described. The effects of sodium spills on cell structures were investigated, including water release from heated concrete, the reaction of sodium with concrete, the formation and spontaneous recombination of hydrogen, and the ability of steel cell liners to withstand large spills of high temperature sodium without leaking

  1. Chemistry of carbon in dynamic sodium

    International Nuclear Information System (INIS)

    Lievens, F.; Casteels, F.

    1980-01-01

    The chemistry of carbon in sodium is described by its chemical activity measurements using alloy monitor foils, by its behaviour in the heat exchanger of the Na 2 sodium loop after 60,000 hours of operation, and by measurements with on-line meters. Efforts toward the identification of the carbon chemical states present in dynamic sodium, and responsible for the carbon chemical activity, are described. (author)

  2. Cosmic ray produced sodium and its applications

    International Nuclear Information System (INIS)

    Goncalves Barbosa, A.

    1981-07-01

    The following topics were presented: calculations of the theoretical production rate of sodium-22 in the atmosphere in order to estimate its activity in rain water; description of the method of chemical separation of sodium and of counting of various radionuclide samples; results obtained for 22 Na, 137 Cs, 144 Ce, 7 Be and 210 Pb and seasonal variations of these radionuclides in rain and river waters; seasonal variations of natural elements, sodium, potassium and uranium in rain and river waters [fr

  3. Chemistry of carbon in dynamic sodium

    Energy Technology Data Exchange (ETDEWEB)

    Lievens, F; Casteels, F [SCK/CEN, Mol (Belgium)

    1980-05-01

    The chemistry of carbon in sodium is described by its chemical activity measurements using alloy monitor foils, by its behaviour in the heat exchanger of the Na 2 sodium loop after 60,000 hours of operation, and by measurements with on-line meters. Efforts toward the identification of the carbon chemical states present in dynamic sodium, and responsible for the carbon chemical activity, are described. (author)

  4. Interferon Gamma-1b Injection

    Science.gov (United States)

    Interferon gamma-1b injection is used to reduce the frequency and severity of serious infections in people with chronic ... severe, malignant osteopetrosis (an inherited bone disease). Interferon gamma-1b is in a class of medications called ...

  5. Sodium cleaning from sodium contaminated components and operation for experimental equipment

    Energy Technology Data Exchange (ETDEWEB)

    Kim, B. H.; Kim, J. M.; Kim, T. J.; Nam, H. Y.; Jeong, J. Y.; Choi, B. H.; Choi, J. H

    2007-11-15

    An objective of washing technology development for sodium contaminated equipment is to clean and reuse safely and effectively the used equipment through a washing and maintenance, and recovery of the sodium wastes generated during washing.

  6. Sodium pool fire analysis of sodium-cooled fast reactor by calculation

    International Nuclear Information System (INIS)

    Yu Hong; Xu Mi; Jin Degui

    2002-01-01

    Theoretical models were established according to the characteristic of sodium pool fire, and the SPOOL code was created independently. Some transient processes in sodium pool fire were modeled, including chemical reaction of sodium and oxygen; sodium combustion heat transfer modes in several kids of media; production, deposition and discharge of sodium aerosol; mass and energy exchange between different media in different ventilating conditions. The important characteristic parameters were calculated, such as pressure and temperature of gas, temperature of building materials, mass concentration of sodium aerosol, and so on. The SPOOL code, which provided available safety analysis tool for sodium pool fire accidents in sodium-cooled fast reactor, was well demonstrated with experimental data

  7. Electrolytic process to produce sodium hypochlorite using sodium ion conductive ceramic membranes

    Science.gov (United States)

    Balagopal, Shekar; Malhotra, Vinod; Pendleton, Justin; Reid, Kathy Jo

    2012-09-18

    An electrochemical process for the production of sodium hypochlorite is disclosed. The process may potentially be used to produce sodium hypochlorite from seawater or low purity un-softened or NaCl-based salt solutions. The process utilizes a sodium ion conductive ceramic membrane, such as membranes based on NASICON-type materials, in an electrolytic cell. In the process, water is reduced at a cathode to form hydroxyl ions and hydrogen gas. Chloride ions from a sodium chloride solution are oxidized in the anolyte compartment to produce chlorine gas which reacts with water to produce hypochlorous and hydrochloric acid. Sodium ions are transported from the anolyte compartment to the catholyte compartment across the sodium ion conductive ceramic membrane. Sodium hydroxide is transported from the catholyte compartment to the anolyte compartment to produce sodium hypochlorite within the anolyte compartment.

  8. Measurement of carbon thermodynamic activity in sodium

    Energy Technology Data Exchange (ETDEWEB)

    Kozlov, F A; Zagorulko, Yu I; Kovalev, Yu P; Alekseev, V V [Institute of Physics and Power Engineering, Obninsk (USSR)

    1980-05-01

    The report presents the brief outline on system of carbon activity detecting system in sodium (SCD), operating on the carbon-permeable membrane, of the methods and the results of testing it under the experimental circulating loop conditions. The results of carbon activity sensor calibration with the use of equilibrium samples of XI8H9, Fe -8Ni, Fe -12Mn materials are listed. The behaviour of carbon activity sensor signals in sodium under various transitional conditions and hydrodynamic perturbation in the circulating loop, containing carbon bearing impurities in the sodium flow and their deposits on the surfaces flushed by sodium, are described. (author)

  9. Excess Sodium Tetraphenylborate and Intermediates Decomposition Studies

    Energy Technology Data Exchange (ETDEWEB)

    Barnes, M.J.

    1998-12-07

    The stability of excess amounts of sodium tetraphenylborate (NaTPB) in the In-Tank Precipitation (ITP) facility depends on a number of variables. Concentration of palladium, initial benzene, and sodium ion as well as temperature provide the best opportunities for controlling the decomposition rate. This study examined the influence of these four variable on the reactivity of palladium-catalyzed sodium tetraphenylborate decomposition. Also, single effects tests investigated the reactivity of simulants with continuous stirring and nitrogen ventilation, with very high benzene concentrations, under washed sodium concentrations, with very high palladium concentrations, and with minimal quantities of excess NaTPB.

  10. Experience on sodium removal from various components

    Energy Technology Data Exchange (ETDEWEB)

    Kamei, M; Kanbe, M; Yagisawa, H; Sasaki, S; Kataoka, H; Fukada, T; Ishii, Y; Saito, R; Mimoto, Y [O-arai Engineering Centre, PNC, Ibaraki-ken, Tokio (Japan)

    1978-08-01

    Since 1970, OEC (O-arai Engineering Center) has been Investigating the following methods for removal of sodium from the components of sodium plants: steam cleaning for the 50 MW Steam Generator, secondary proto-type pump of 'JOYO' and Dummy fuel assembly of 'JOYO', alcohol cleaning for Sector Model of Intermediate Heat Exchanger (IHX) of 'JOYO', a sector model of Sodium-to-Air cooler of 'JOYO' and a proto-type isolation valve of 'JOYO' and cleaning by vacuumization at high temperature for Regenerative Heat Exchanger. This report describes the outline of the Sodium Disposal Facility and experience of sodium removal processing on the 50 MW Steam Generator, the crevices of the experimental sub-assemblies, the Fuel Handling Machine of 'MONJU' and the Regenerative Heat Exchanger of the Sodium Flow Test Facility. Through these experiences it was noted that, (1) Removal of sodium from crevices such as in bolted joints are very difficult. (2) Consideration is needed in the removal process where material damage might occur from the generation of hydro-oxides. (3) Some detection device to tell the completion of sodium removal as well as the end of reaction is required. (4) Requalification rules should be clarified. Efforts in this direction have been made in the case of a 'JOYO' prototype pump by reinstalling it after sodium removal five times. (author)

  11. Dissolution of LMFBR fuel-sodium aerosols

    International Nuclear Information System (INIS)

    Allen, M.D.; Moss, O.R.

    1979-01-01

    Plutonium dioxide, normally insoluble in biological fluids, becomes much more soluble when mixed with sodium as the aerosol is formed. Sodium-fuel aerosols are approximately 20 times less soluble in simulated lung fluid than in distilled water. Solubility of sodium-fuel aerosols increases when Na 2 CO 3 are added to the distilled-water dissolution fluid. Mixed-oxide fuel aerosols without sodium present are relatively insoluble in distilled water, simulated lung fluid, and distilled water with Na 2 CO 3 and NaHCO 3 added

  12. Sodium-blood pressure interrelationship in pregnancy.

    Science.gov (United States)

    Franx, A; Steegers, E A; de Boo, T; Thien, T; Merkus, J M

    1999-03-01

    In non-pregnant individuals, a strong positive association of sodium intake with blood pressure has been established, but the relationship between sodium intake and blood pressure in human pregnancy remains obscure up to date. The aim of this prospective observational cohort study was to assess the relationship between urinary sodium excretion (as a measure for intake) and blood pressure from the early second trimester onwards throughout pregnancy. The study group consisted of 667 low-risk women with singleton pregnancies, of whom 350 were nulliparous and 317 parous. Blood pressure was measured in a standardised fashion at predetermined intervals from the first antenatal visit prior to 16 weeks gestation until delivery. Urinary sodium excretion was measured in 24-h urine collections on at least four occasions between 16 and 38 weeks gestation. Main outcome measures were the coefficients of correlation between changes in urinary sodium output and changes in blood pressure during six different gestational epochs. No significant correlations were found between changes in urinary sodium output and changes in blood pressure. Correlation coefficients were alike for nulliparous and parous women and for different gestational intervals. Prior to 32 weeks gestation, no differences were observed in sodium excretion between women who remained normotensive and those who developed gestational hypertension. These results suggest that changes in sodium intake are not associated with blood pressure changes in low-risk pregnant women. Blood pressure increases as observed in the second half of normotensive and hypertensive pregnancies are unlikely to be caused by changes in renal sodium handling.

  13. Methods and means of sodium fire fighting

    International Nuclear Information System (INIS)

    Zemskij, G.T.

    1985-01-01

    Methods and means for coaling sodium fire fighting are analyzed. Their advantages and drawbacks are considered. Comparative data on sodium fire fighting using some of considered compositions are presented. High efficiency of self-expanding compositions (Grafeks SK-23 and RS) is noted. Properties of MGS new composition for sodium fire fighting are considered. High fighting ability of the composition independent of burning metal layer width is shown. It is noted that fire fighting MGS efficiency decreases with growth of time of free fire burning which affects fire fighting methods. Technical means of powder delivery to burning sodium are reported

  14. Intelligent type sodium instrumentations for LMFBR

    International Nuclear Information System (INIS)

    Chen Daolong

    1996-07-01

    The constructions and performances of lots of newly developed intelligent type sodium instrumentations are described. The graduation characteristic equations for corresponding transducer using the medium temperature as the parameter are given. These intelligent type sodium instrumentations are possessed of good linearity. The accurate measurement data of sodium process parameters (flowrate, pressure and level) can be obtained by means of their on-line compensation function of the temperature effect. Moreover, these intelligent type sodium instrumentations are possessed of the self-inspection, the electric shutoff protection, the setting of full-scale, the setting of alarm limits (two upper limits and two lower limits alarms), the thermocouple breaking alarm, mutual isolative the 0∼10 V direct-current analogue output and the CENTRONICS standard digital output, and the alarm relay contact output. Theses intelligent type sodium instrumentations are suitable particularly for the instrument, control and protective systems of LMFBR by means of these excellent functions based on microprocessor. The basic errors of the intelligent type sodium flowmeter, immersed sodium flowmeter, sodium manometer and sodium level gauge are +-2%, +-2.3%, +-0.3% and +-1.9% of measuring ranges respectively. (9 figs.)

  15. Experience on sodium removal from various components

    International Nuclear Information System (INIS)

    Kamei, M.; Kanbe, M.; Yagisawa, H.; Sasaki, S.; Kataoka, H.; Fukada, T.; Ishii, Y.; Saito, R.; Mimoto, Y.

    1978-01-01

    Since 1970, OEC (O-arai Engineering Center) has been Investigating the following methods for removal of sodium from the components of sodium plants: steam cleaning for the 50 MW Steam Generator, secondary proto-type pump of 'JOYO' and Dummy fuel assembly of 'JOYO', alcohol cleaning for Sector Model of Intermediate Heat Exchanger (IHX) of 'JOYO', a sector model of Sodium-to-Air cooler of 'JOYO' and a proto-type isolation valve of 'JOYO' and cleaning by vacuumization at high temperature for Regenerative Heat Exchanger. This report describes the outline of the Sodium Disposal Facility and experience of sodium removal processing on the 50 MW Steam Generator, the crevices of the experimental sub-assemblies, the Fuel Handling Machine of 'MONJU' and the Regenerative Heat Exchanger of the Sodium Flow Test Facility. Through these experiences it was noted that, (1) Removal of sodium from crevices such as in bolted joints are very difficult. (2) Consideration is needed in the removal process where material damage might occur from the generation of hydro-oxides. (3) Some detection device to tell the completion of sodium removal as well as the end of reaction is required. (4) Requalification rules should be clarified. Efforts in this direction have been made in the case of a 'JOYO' prototype pump by reinstalling it after sodium removal five times. (author)

  16. Experience on sodium removal from various components

    International Nuclear Information System (INIS)

    Kamei, M.; Kanbe, M.; Yagisawa, H.; Sasaki, S.; Kataoka, H.

    1978-02-01

    Since 1970, OEC (O-arai Engineering Center) has been investigating the following methods for removal of sodium from the components of sodium plants: steam cleaning for the 50 MW Steam Generator, secondary proto-type pump of ''JOYO'' and Dummy fuel assembly of ''JOYO'', alcohol cleaning for Sector Model of Intermediate Heat Exchanger (IHX) of ''JOYO'', a sector model of Sodium-to-Air cooler of ''JOYO'' and a proto-type Isolation valve of ''JOYO'' and cleaning by vacuumization at high temperature for Regenerative Heat Exchanger. This report describes the outline of the Sodium Disposal Facility and experience of sodium removal processing on the 50 MW Steam Generator, the crevices of the experimental subassemblies, the Fuel Handling Machine of ''MONJU'' and the Regenerative Heat Exchanger of the Sodium Flow Test Facility. Through these experiences it was noted that, (1) Removal of Sodium from crevices such as in bolted joints are very difficult. (2) Consideration is needed in the removal process where material damage might occur from the generation of hydro-oxides. (3) Some detection device to tell the completion of sodium removal as well as the end of reaction is required. (4) Requalification rules should be clarified. Efforts in this direction have been made in the case of a ''JOYO'' prototype pump by reinstalling it after sodium removal five times. (author)

  17. Method for processing radioactive wastes containing sodium

    International Nuclear Information System (INIS)

    Kubota, Takeshi.

    1975-01-01

    Object: To bake, solidify and process even radioactive wastes highly containing sodium. Structure: H and or NH 4 zeolites of more than 90g per chemical equivalent of sodium present in the waste is added to and left in radioactive wastes containing sodium, after which they are fed to a baker such as rotary cylindrical baker, spray baker and the like to bake and solidify the wastes at 350 to 800 0 C. Thereby, it is possible to bake and solidify even radioactive wastes highly containing sodium, which has been impossible to do so previously. (Kamimura, M.)

  18. Injecting drug use: Gendered risk.

    Science.gov (United States)

    Zahnow, Renee; Winstock, Adam R; Maier, Larissa J; Levy, Jay; Ferris, Jason

    2018-06-01

    Research demonstrates gender related differences in drug-use practices and risk behaviours. Females' structural vulnerability stemming from traditional gender roles and gender-power relations may enhance their propensity to experience injecting related risk. In this paper we explore gender differences in injection practices at the initiation event, during the first year of injecting and in the most recent 12-month period, to inform more effective harm reduction strategies. Data used in this study were drawn from the Global Drug Survey 2015. The study employs chi-square and logistic regression to assess gender differences in injection behaviours in a sample of current injectors residing in six global regions: North-West Europe; Southern Eastern Europe; North America. South America and Oceania. Females were more likely than males to report being injected by an intimate partner at initiation (OR = 4.4, 95%CI: 2.2-8.8), during the first year of injecting (OR = 4.8, 95% CI: 2.4-9.3) and in the most recent 12-month period (OR = 2.5, 95%CI: 1.0-6.2). Females reported greater difficulties accessing sterile equipment (X 2 (2,N = 453) = 8.2, p = 0.02) and were more likely to share injecting equipment than males (X 2 (1,N = 463) = 3.9, p = 0.05). Our findings highlight females' continued dependence on their intimate partner to administer the injection into the first year of their injecting career. Females remained more likely than males to rely on intimate partners for injection during the most recent 12-month period. Females report greater difficulties in sourcing sterile equipment and are more likely to share injecting equipment. We suggest that these findings reflect the broader social structure in which females are disempowered through traditional gender roles and the lack of gender appropriate harm reduction services. Copyright © 2018 Elsevier B.V. All rights reserved.

  19. Vocal fold injection medialization laryngoplasty.

    Science.gov (United States)

    Modi, Vikash K

    2012-01-01

    Unilateral vocal fold paralysis (UVFP) can cause glottic insufficiency that can result in hoarseness, chronic cough, dysphagia, and/or aspiration. In rare circumstances, UVFP can cause airway obstruction necessitating a tracheostomy. The treatment options for UVFP include observation, speech therapy, vocal fold injection medialization laryngoplasty, thyroplasty, and laryngeal reinnervation. In this chapter, the author will discuss the technique of vocal fold injection for medialization of a UVFP. Copyright © 2012 S. Karger AG, Basel.

  20. Accidental epidural injection of Atropine

    Directory of Open Access Journals (Sweden)

    Udayan Bakshi

    2013-01-01

    Full Text Available Intrathecal injection of drugs for anesthesia, regional analgesia, and chronic pain management are common practice now. Local anesthetic, adjuvants, and opioids are in common use. Human error in the Operation Theater and the Intensive Care Unit setup is also known and reported, due to stress and overwork. A case of unintentional atropine injection intrathecally, which was closely observed for any untoward effects, is reported here.

  1. Sodium-cooled nuclear reactor

    International Nuclear Information System (INIS)

    Hammers, H.W.

    1982-01-01

    The invention concerns a sodium-cooled nuclear reactor, whose reactor tank contains the primary circuit, shielding surrounding the reactor core and a primary/secondary heat exchanger, particularly a fast breeder reactor on the module principle. In order to achieve this module principle it is proposed to have electromagnetic circulating pumps outside the reactor tank, where the heat exchanger is accomodated in an annular case above the pumps. This case has several openings at the top end to the space above the reactor core, some smaller openings in the middle to the same space and is connected at the bottom to an annular space between the tank wall and the reactor core. As a favoured variant, it is proposed that the annular electromagnetic pumps should be arranged concentrically to the reactor tank, where there is an annual duct on the inside of the reactor tank. In this way the sodium-cooled nuclear reactor is made suitable as a module with a large number of such elements. (orig.) [de

  2. Operating experience with sodium valves in the TNO-sodium test facilities

    International Nuclear Information System (INIS)

    Gasselt, M.L.G. van

    1974-01-01

    The development of sodium components for the SNR-300 in Holland has reached the stage where full scale testing in sodium has almost been finished and construction is at its height. It is against this background that a review is given of the weaknesses in one area or the other of the commercially available types of sodium valves used in TNO's smaller test facilities at Apeldoorn and TNO's 50 MW sodium components test facility at Hengelo. (U.S.)

  3. Improving the Corrosion Inhibitive Strength of Sodium Sulphite in Hydrogen Cyanide Solution Using Sodium Benzoate

    OpenAIRE

    Muhammed Olawale Hakeem AMUDA; Olusegun Olusoji SOREMEKUN; Olakunle Wasiu SUBAIR; Atinuke OLADOYE

    2008-01-01

    The improvement in the inhibitive strength of sodium sulphite on corrosion of mild steel in hydrogen cyanide by adding sodium benzoate in regulated volume was investigated using the fundamental weight loss measurement.500 ppm concentration inhibitive mixtures of sodium benzoate and sodium sulphite in three different volume ratios (5/15, 10/10, 15/5) were formulated and studied for corrosion rate in 200ml hydrogen cyanide fluid. Result obtained indicates that the corrosion rate of mild steel i...

  4. Injection and extraction for cyclotrons

    International Nuclear Information System (INIS)

    Heikkinen, P.

    1994-01-01

    External ion sources for cyclotrons are needed for polarised and heavy ions. This calls for injection systems, either radial or axial. Radial injection is also needed when a cyclotron works as a booster after another cyclotron or a linear accelerator (usually tandem). Requirements for injection differ from separated sector cyclotrons where there is plenty of room to house inflectors and/or strippers, to superconducting cyclotrons where the space is limited by a small magnet gap, and high magnetic field puts other limitations to the inflectors. Several extraction schemes are used in cyclotrons. Stripping injection is used for H - and also for heavy ions where the q/m ratio is usually doubled. For other cases, electric and magnetic deflection has to be used. To increase the turn separation before the first deflector, both resonant and non-resonant schemes are used. In this lecture, external injection systems are surveyed and some rules to thumb for injection parameters are given. Extraction schemes are also reviewed. (orig.)

  5. ITER Neutral Beam Injection System

    International Nuclear Information System (INIS)

    Ohara, Yoshihiro; Tanaka, Shigeru; Akiba, Masato

    1991-03-01

    A Japanese design proposal of the ITER Neutral Beam Injection System (NBS) which is consistent with the ITER common design requirements is described. The injection system is required to deliver a neutral deuterium beam of 75MW at 1.3MeV to the reactor plasma and utilized not only for plasma heating but also for current drive and current profile control. The injection system is composed of 9 modules, each of which is designed so as to inject a 1.3MeV, 10MW neutral beam. The most important point in the design is that the injection system is based on the utilization of a cesium-seeded volume negative ion source which can produce an intense negative ion beam with high current density at a low source operating pressure. The design value of the source is based on the experimental values achieved at JAERI. The utilization of the cesium-seeded volume source is essential to the design of an efficient and compact neutral beam injection system which satisfies the ITER common design requirements. The critical components to realize this design are the 1.3MeV, 17A electrostatic accelerator and the high voltage DC acceleration power supply, whose performances must be demonstrated prior to the construction of ITER NBI system. (author)

  6. Home blood sodium monitoring, sliding-scale fluid prescription and subcutaneous DDAVP for infantile diabetes insipidus with impaired thirst mechanism

    Directory of Open Access Journals (Sweden)

    Hameed Shihab

    2012-06-01

    Full Text Available Abstract Background/Aims Infants with diabetes insipidus (DI, especially those with impaired thirst mechanism or hypothalamic hyperphagia, are prone to severe sodium fluctuations, often requiring hospitalization. We aimed to avoid dangerous fluctuations in serum sodium and improve parental independence. Methods A 16-month old girl with central DI, absent thirst mechanism and hyperphagia following surgery for hypothalamic astrocytoma had erratic absorption of oral DDAVP during chemotherapy cycles. She required prolonged hospitalizations for hypernatremia and hyponatremic seizure. Intensive monitoring of fluid balance, weight and clinical assessment of hydration were not helpful in predicting serum sodium. Discharge home was deemed unsafe. Oral DDAVP was switched to subcutaneous (twice-daily injections, starting with 0.01mcg/dose, increasing to 0.024mcg/dose. The parents adjusted daily fluid allocation by sliding-scale, according to the blood sodium level (measured by handheld i-STAT analyser, Abbott. We adjusted the DDAVP dose if fluid allocation differed from maintenance requirements for 3 consecutive days. Results After 2.5 months, sodium was better controlled, with 84% of levels within reference range (135-145 mmol/L vs. only 51% on the old regimen (p = 0.0001. The sodium ranged from 132-154 mmol/L, compared to 120–156 on the old regimen. She was discharged home. Conclusion This practical regimen improved sodium control, parental independence, and allowed discharge home.

  7. Home blood sodium monitoring, sliding-scale fluid prescription and subcutaneous DDAVP for infantile diabetes insipidus with impaired thirst mechanism.

    Science.gov (United States)

    Hameed, Shihab; Mendoza-Cruz, Abel C; Neville, Kristen A; Woodhead, Helen J; Walker, Jan L; Verge, Charles F

    2012-06-09

    Infants with diabetes insipidus (DI), especially those with impaired thirst mechanism or hypothalamic hyperphagia, are prone to severe sodium fluctuations, often requiring hospitalization. We aimed to avoid dangerous fluctuations in serum sodium and improve parental independence. A 16-month old girl with central DI, absent thirst mechanism and hyperphagia following surgery for hypothalamic astrocytoma had erratic absorption of oral DDAVP during chemotherapy cycles. She required prolonged hospitalizations for hypernatremia and hyponatremic seizure. Intensive monitoring of fluid balance, weight and clinical assessment of hydration were not helpful in predicting serum sodium. Discharge home was deemed unsafe. Oral DDAVP was switched to subcutaneous (twice-daily injections, starting with 0.01mcg/dose, increasing to 0.024mcg/dose). The parents adjusted daily fluid allocation by sliding-scale, according to the blood sodium level (measured by handheld i-STAT analyser, Abbott). We adjusted the DDAVP dose if fluid allocation differed from maintenance requirements for 3 consecutive days. After 2.5 months, sodium was better controlled, with 84% of levels within reference range (135-145 mmol/L) vs. only 51% on the old regimen (p = 0.0001). The sodium ranged from 132-154 mmol/L, compared to 120-156 on the old regimen. She was discharged home. This practical regimen improved sodium control, parental independence, and allowed discharge home.

  8. New injection recommendations for patients with diabetes

    NARCIS (Netherlands)

    Frid, A.; Hirsch, L.; Gaspar, R.; Hicks, D.; Kreugel, G.; Liersch, J.; Letondeur, C.; Sauvanet, J. P.; Tubiana-Rufi, N.; Strauss, K.

    Aim: Injections administered by patients are one of the mainstays of diabetes management. Proper injection technique is vital to avoiding intramuscular injections, ensuring appropriate delivery to the subcutaneous tissues and avoiding common complications such as lipohypertrophy. Yet few formal

  9. Alginate hydrogel as a potential alternative to hyaluronic acid as submucosal injection material.

    Science.gov (United States)

    Kang, Ki Joo; Min, Byung-Hoon; Lee, Jun Haeng; Kim, Eun Ran; Sung, Chang Ohk; Cho, Joo Young; Seo, Soo Won; Kim, Jae J

    2013-06-01

    Sodium alginate is currently used in medical products, including drugs and cosmetic materials. It can also be used as a submucosal injection material due to its excellent water retention ability. Alginate with a high water retention ability is called alginate hydrogel (AH). The aim of this study was to investigate the usefulness of AH as a submucosal injection material. To investigate the optimal viscosity of AH as a submucosal injection material, we observed the changes in submucosal height from the initial submucosal height in the stomachs of six miniature pigs for each injection material tested (0.3 % AH, 0.5 % hyaluronic acid, glycerol). All submucosal heights were compared serially over time (3, 5, 10, 20, and 30 min). Both immediate and 1-week delayed tissue reactions were investigated endoscopically in the same living pigs. Histological analyses were performed after the animals had been sacrificed. In a preliminary study, we determined that 0.3 % sodium alginate mixed with BaCl2 (400 μl) was the optimal viscosity of AH as an injection material. Our comparison of submucosal height changes over time showed that there was a significant decrease in submucosal height just 3 min following the injection of hyaluronic acid and glycerol, but that following the injection of AH a significant decrease in submucosal height was observed only after 10 min (p injection site. Alginate hydrogel demonstrated long-lasting maintenance of submucosal elevation, safety, and cost-effectiveness in a pig model, which makes it a potential alternative to hyaluronic acid.

  10. Compared With Usual Sodium Intake, Low- and Excessive-Sodium Diets Are Associated With Increased Mortality

    DEFF Research Database (Denmark)

    Graudal, Niels; Jürgens, Gesche; Baslund, Bo

    2014-01-01

    BACKGROUND: The effect of sodium intake on population health remains controversial. The objective was to investigate the incidence of all-cause mortality (ACM) and cardiovascular disease events (CVDEs) in populations exposed to dietary intakes of low sodium (<115 mmol), usual sodium (low usual so...

  11. Control of sodium fires and sodium-water reactions in breeder reactors

    International Nuclear Information System (INIS)

    Foerster, K.; Ruloff, G.; Voss, J.

    1985-01-01

    The excellent neutronic and thermodynamic properties of sodium as a fast-reactor coolant are somewhat counterbalanced by its high oxygen affinity. Because incidents like sodium fires and sodium-water reactions cannot be absolutely excluded, their effects and preventive measures have to be investigated. Characteristics and counter-measures are discussed. (orig.) [de

  12. An experimental study on tissue damage following subcutaneous injection of water soluble contrast media

    International Nuclear Information System (INIS)

    Kim, Seung Hyup; Park, Jae Hyung; Kang, Heung Sik; Kim, Chu Wan; Han, Man Chung; Kim, Yong Il

    1989-01-01

    The water soluble contrast media cause tissue necrosis infrequently by extravasation during intravenous injection in various radiological examinations. However, it has not been well documented that what kind and what concentration of contrast media can cause tissue necrosis. And also, the mechanism of tissue necrosis by extravasated contrast media has not been well known. The purpose of this experimental study was to evaluate the frequency and severity of tissue damage following subcutaneous injection of various water soluble contrast media to investigate the characteristics of the contrast media acting on the tissue damage, and to provide the basic data for the clinical application. Meglumine ioxithalamate,sodium and meglumine ioxithalamate, iopromide, iopamidol, ioxaglate,meglumine diatrizoate and sodium diatrizoate of various iodine content and osmolality were injected into subcutaneous tissue of the dorsum of 970 feet of 485 rats. The tissue reaction of injection sites were grossly examined with period from 1 day to 8 weeks after the injection. Representative gross changes were correlated with histologic findings. The results were as follows; 1. The basic tissue damage by extravasated contrast media was acute and chronic inflammatory reaction of the soft tissue with subsequent progress into the hemorrhagic and necrotizing lesion. 2. Lager volume of contrast media caused more severe tissue damage. 3. Contrast media of higher osmolality caused more severe tissue damage. 4. At same osmolality, contrast media of higher iodine content caused more severe tissue damage

  13. Fragmentation of a single molten copper and silver droplets penetrating a sodium pool with solid crust

    International Nuclear Information System (INIS)

    Wataru Itagaki; Ken-ichiro Sugiyama; Satoshi Nishimura; Izumi Kinoshita

    2005-01-01

    As a basic study of molten fuel-coolant interaction in liquid metal fast cooled reactors, we carried out a series of experiments for the fragmentation of molten copper droplet penetrating sodium pool at instantaneous contact interface temperatures below its freezing point. A single molten copper droplet with 5g in weight and with superheating varied from 0 degree C to 131 degree C was dropped into a sodium pool in a wide range of ambient Weber numbers 24 to 228. In addition to the experiment of molten copper droplet, molten silver droplet with 5gs in weight and with superheating varied from 3 degree C to 174 degree C was dropped into the sodium pool at an ambient Weber number of about 80. From the observation of the cross section of solidified silver droplet without fragmentation, it was clearly confirmed that sodium micro jet is driven into the inside from the upper surface of molten droplet keeping liquid phase, which is clear evidence for the thermal fragmentation mechanism proposed in the previous paper. Large scattering in the values of dimensionless mass median diameter observed in the present experimental study is recognized to be dependent on whether latent heat instantaneously released due to the injection of sodium micro jet can be effectively utilized for fragmentation. (authors)

  14. Accident alarm in steam generators in sodium cooled fast reactor power plants. II

    International Nuclear Information System (INIS)

    Matal, O.; Martoch, J.; Taraba, O.; Hanke, V.

    1978-01-01

    Conditions were simulated in the economizer of a steam generator of water leaks in sodium at a sodium flow of O.62x10 -3 to 1.24x10 -3 m 3 /s and a sodium temperature of 320 to 380 degC by injecting water at a pressure of 6 to 10 MPa which roughly corresponds to conditions in an economizer of an actual steam generator with leaks within the limits of 0.01 to 0.3 g/s. The leak was recorded by acoustic detectors at all observed sodium flow rates and temperatures. The mean signal-to-noise ratio was in all cases greater than 2. At the assumed 25 dB noise level of the real steam generator of micromodular design it may be assumed that using existing acoustic detectors with waveguides a 0.02 g/s leak of water into sodium may be detected. The measurements showed that the technical standard of the equipment is at least as good as that of the flowmeter system of accident monitoring. (J.B.)

  15. Sodium ordering and the control of magnetism in sodium cobaltate

    International Nuclear Information System (INIS)

    Morris, D.J.P.; Roger, M.; Tennant, D.A.; Goff, J.P.; Gutmann, M.J.; Hoffmann, J.-U.; Prabhakaran, D.; Shannon, N.; Lake, B.; Deen, P.P.

    2007-01-01

    The long-range three-dimensional ordering of Na + ions was studied in a sample of composition Na 0.75 CoO 2 using single-crystal neutron diffraction. Large-scale numerical simulations reveal the ordering principle for this system, the formation of multi-vacancy charged droplets then order long range, and the structure factors from these defect clusters are in good agreement with the observed neutron diffraction intensities. The electrostatic potential is found to be the dominant factor in determining the sodium ordering and its associated distortion field. The superstructures induce a periodic potential in the CoO 2 , giving potential wells that are larger than the single-particle hopping frequency and so able to localize holes. The results readily explain many of the observed electrical and magnetic properties, including the three dimensionality of the magnetic excitations

  16. 21 CFR 172.822 - Sodium lauryl sulfate.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Sodium lauryl sulfate. 172.822 Section 172.822 Food... Multipurpose Additives § 172.822 Sodium lauryl sulfate. The food additive sodium lauryl sulfate may be safely... specifications: (1) It is a mixture of sodium alkyl sulfates consisting chiefly of sodium lauryl sulfate [CH2(CH2...

  17. Sodium fires. Progress achieved in research and experimental results

    International Nuclear Information System (INIS)

    Malet, J.C.; Duverger de Cuy, G.; Casselman, C.; Charpenel, J.; Natta, M.; Devillers, C.

    1979-08-01

    This paper describes the sodium fire programs undertaken by the CEA's Nuclear Safety Department. Experimental results concerning sodium ignition and combustion, sodium fire suppression, sodium aerosol filtration and sodium-concrete contact reactions are given and the applications of these results in the Super-Phenix reactor is discussed

  18. Tumorigenicity of sodium ascorbate in male rats.

    Science.gov (United States)

    Cohen, S M; Anderson, T A; de Oliveira, L M; Arnold, L L

    1998-06-15

    Sodium ascorbate, like other sodium salts such as saccharin, glutamate, and bicarbonate, produces urinary alterations when fed at high doses to rats, which results in mild superficial urothelial cytotoxicity and regeneration but not tumors in a standard 2-year bioassay. Sodium saccharin was shown to produce a low incidence of bladder tumors in rats if administered in a two-generation bioassay. In the present study, we evaluated sodium ascorbate in a two-generation bioassay that involved feeding to the male and female parental F344 rats for 4 weeks before mating, feeding the dams during gestation and lactation, and then feeding the weaned (at 28 days of age) male F1 generation rats for the remainder of their lifetime (up to 128 weeks of the experiment). Dietary levels of 1.0, 5.0, and 7.0% sodium ascorbate were tested. At 5.0 and 7.0% sodium ascorbate, there was an increase in urinary bladder urothelial papillary and nodular hyperplasia and the induction of a few papillomas and carcinomas. There was a dose-responsive increase in renal pelvic calcification and hyperplasia and inhibition of the aging nephropathy of rats even at the level of 1% sodium ascorbate. Because the short-term urothelial effects of sodium ascorbate in rats are inhibited by treatments producing urinary acidification to pH sodium ascorbate to evaluate the long-term effects. The combination of 7.0% sodium ascorbate plus 2.78% NH4Cl in the diet was toxic, and the group was terminated early during the course of the experiment. The group fed 5.0% sodium ascorbate plus 2.04% NH4Cl showed complete inhibition of the urothelial effects of sodium ascorbate and significant inhibition of its renal effects. We also demonstrated the presence of a calcium phosphate-containing urinary precipitate in rats fed sodium ascorbate at all doses, in a dose-responsive manner. The formation of the precipitate was inhibited by coadministration with NH4Cl. The proliferative effects of sodium ascorbate on the male rat

  19. Determination of sodium in pharmaceuticals by neutron activation analysis

    International Nuclear Information System (INIS)

    Kanias, G.D.

    1985-01-01

    A simple, fast and accurate neutron activation analysis method for determination of Na in drugs concerning either active compound or total content was developed. The examined dosage forms consisted of 10 injectable ampoules and 10 bottles of oral solutions. The irradiation of samples and standards was carried out in the rotation system of the Reactor of Nuclear Research Center Democritos with maximal neutron flux of 2,9.10 13 n.cm -2 .sec -1 . Gamma-ray spectrometry of the irradiated samples and standards was accomplished with a coaxial Ge(Li) detector series Win 15 with an efficiency of 15% connected to an Ino-Tech 1024 channel analyser (Model IT 5200). The accuracy and precision of the method are found to be very high and therefore it could be established as an official one for the determination of sodium in parmaceuticals

  20. Combustion of sodium in the open atmosphere

    Energy Technology Data Exchange (ETDEWEB)

    Morewith, H A; Johnson, R P; Nelson, C T; Otter, J M [Energy System Group, Rockwell International, Rockwell (United States)

    1979-03-01

    A series of sodium fire tests has been conducted in ambient air at a meteorological test site. This test series was designed to simulate hypothetical accidents which might occur in the heat transport system of an LMFBR. Measurements of concentration, agglomeration, fallout, and chemical species of the sodium combustion products were made as a function of downwind distance. In each of the first two tests, {approx}23 kg of 540 deg. C sodium was sprayed as a fan of 250-{mu}m sodium drops across the wind, from heights of 5 or 6 m. Each release took a few minutes. A dense sodium combustion product aerosol was formed, and quickly agglomerated to large (100 to 660 {mu}m) diameter particles. More than 50% of the aerosol mass fell out within several hundred meters of the release point. Two additional tests were performed by releasing sodium through 9.5-mm diameter jets at a height of 30 m. In each test, the sodium jet was aimed horizontally across the wind, and followed a downward parabolic trajectory, releasing burning sodium drops along its track. Again, close-in fallout due to large agglomerates was observed. A substantial amount of unburned sodium fell 30 m to the ground, where it burned. In a third type of test, sodium was burned for 60 min as pool in a 1.5m{sup 2} burn pan at 9 m/s wind velocity. Approximately 30% of the combustion products became airborne. Large agglomerates fell out as they moved downwind, depositing 1 kg/m{sup 2} at 1 m downwind from the edge of the pan. Chemical analysis of the samples indicated that the sodium fires produced mainly Na{sub 2}O, and that the conversion of NaOH was slow. Comparison were made with COMRADEX-IV code models, which are appropriate for calculating deposition and concentrations for downwind distances between 10{sup 2} and 10{sup 4} m. (author)