  1. Dedicated low-field MRI in mice

    International Nuclear Information System (INIS)

    Choquet, P; Breton, E; Goetz, C; Constantinesco, A; Marin, C

    2009-01-01

    The rationale of this work is to point out the relevance of in vivo MR images of mice obtained using a dedicated low-field system. For this purpose a small 0.1 T water-cooled electro-magnet and solenoidal radio frequency (RF) transmit-receive coils were used. All MR images were acquired in three-dimensional (3D) mode. An isolation cell was designed allowing easy placement of the RF coils and simple delivery of gaseous anesthesia as well as warming of the animal. Images with and without contrast agent were obtained in total acquisition times on the order of half an hour to four hours on normal mice as well as on animals bearing tumors. Typical in plane pixel dimensions range from 200 x 200 to 500 x 500 μm 2 with slice thicknesses ranging between 0.65 and 1.50 mm. This work shows that, besides light installation and low cost, dedicated low-field MR systems are suitable for small rodents imaging, opening this technique even to small research units.

  2. Dedicated low-field MRI in mice

    Science.gov (United States)

    Choquet, P.; Breton, E.; Goetz, C.; Marin, C.; Constantinesco, A.

    2009-09-01

    The rationale of this work is to point out the relevance of in vivo MR images of mice obtained using a dedicated low-field system. For this purpose a small 0.1 T water-cooled electro-magnet and solenoidal radio frequency (RF) transmit-receive coils were used. All MR images were acquired in three-dimensional (3D) mode. An isolation cell was designed allowing easy placement of the RF coils and simple delivery of gaseous anesthesia as well as warming of the animal. Images with and without contrast agent were obtained in total acquisition times on the order of half an hour to four hours on normal mice as well as on animals bearing tumors. Typical in plane pixel dimensions range from 200 × 200 to 500 × 500 µm2 with slice thicknesses ranging between 0.65 and 1.50 mm. This work shows that, besides light installation and low cost, dedicated low-field MR systems are suitable for small rodents imaging, opening this technique even to small research units.

  3. Development of a simple photon emission computed tomography dedicated to the small animal

    International Nuclear Information System (INIS)

    Bekaert, V.

    2006-11-01

    The development of in vivo small animal imaging becomes essential to study human pathologies. The ImaBio project of Institut Pluridisciplinaire Hubert Curien (IPHC) fits in the process of developing new instruments for biomedical applications with the development of a multimodality imaging platform dedicated to small animal imaging (AMISSA). This thesis presents the study, the design and the development of a Single Photon Emission Computed Tomography (SPECT) which will be integrated to the AMISSA platform. The result of these developments is the possibility to obtain the spatial distribution of an injected molecule into the animal. The SPECT technical solutions are based on the acquired knowledge of the institute allowing the conception of a device with cameras adapted to the gamma detection produced by the radiotracers used in single photon imaging. In order to cover the entire of the transverse field of view, four gamma cameras are arranged in a ring around the volume of interest. Each camera consists of 5 individual modules based on a YAP:Ce crystal array, a multi-anode photomultiplier and a dedicated multichannel electronic device. Finally, 20 detection modules were calibrated to give the same result for an identical energy deposit. The data are acquired then process to extract the positions and the energies deposited by gamma photons in the crystals. This last information is then gathered to build the projections. The 3D reconstructed image from the projections is carried out by the sequence of two algorithms, analytical and iterative OS-EM, both modified to take into account the singular geometry of our detection system. Finally, the obtained image is fused with the anatomical information given by the micro Computed Tomography system. (author)

  4. Magnetic resonance imaging in ophthalmic diagnosis. Results of examinations using a small field-of-view surface coil

    International Nuclear Information System (INIS)

    Kato, Yuji; Yoshida, Akitoshi; Kanno, Harumi; Ogasawara, Hironobu; Murakami, Noboru; Cheng, Hong-Ming.

    1997-01-01

    We obtained T 1 -and T 2 -weighted magnetic resonance (MR) images in 3 patients with vitreoretinal disorders using a recently developed surface coil that was inductively coupled and had a small field of view. On both T 1 -and T 2 -weighted images, tractional retinal detachment was clearly detected in the first patient, who had proliferative diabetic retinopathy. T 1 - and T 2 -weighted images of the second patient, who had total retinal detachment with proliferative vitreous retinopathy, revealed a funnel-shaped thickened retina. The third patient had postoperative rhegmatogenous retinal detachment with opacity due to postoperative cataract and intravitreous injection of gas; on this patient's MR images we could clearly differentiate the reattached retina, silicone used for scleral buckling, and intravitreous gas, even though these differentiations were not possible with ophthalmoscopy or B-scan ultrasonography. High resolution MR imaging with our technique can be performed in a short time and regardless of the eye's condition. Our findings strongly indicate that MRI with a small field-of-view surface coil is a useful tool for diagnosing various vitreoretinal disorders and observing pathological changes. (author)

  5. Rarity of isolated pulmonary embolism and acute aortic syndrome occurring outside of the field of view of dedicated coronary CT angiography

    International Nuclear Information System (INIS)

    Lee, Hwa Yeon; Song, In Sup; Yoo, Seung Min; Rho, Ji Young; Moon, Jae Youn; Kim, In Jai; Lim, Sang Wook; Sung, Jung Hoon; Cha, Dong Hun; White, Charles S.

    2011-01-01

    Background Although triple rule-out CT angiography (TRO) to simultaneously evaluate acute coronary syndrome (ACS), pulmonary embolism (PE), and acute aortic syndrome (AAS) is increasingly used in many institutions, TRO is inevitably associated with increased radiation exposure due to extended z-axis coverage compared with dedicated coronary CT angiography (DCTA). Purpose To determine the frequency of exclusion of findings of AAS, PE, and significant incidental non-cardiac pathology that may be the cause of acute chest pain when using a restricted DCTA field of view (FOV). Material and Methods We retrospectively reviewed CT images and charts of 103 patients with acute PE and 50 patients with AAS. Either non-ECG gated dedicated pulmonary or aortic CT angiography was performed using 16- or 64-slice multidetector CT (MDCT). We analyzed the incidence of isolated PE, AAS, or significant non-cardiac pathology outside of DCTA FOV (i.e. from tracheal carina to the base of heart). Results There were two cases of isolated PE (2/103, 1.9%) excluded from the FOV of DCTA. One case of PE was isolated to the subsegmental pulmonary artery in the posterior segment of the right upper lobe. In the second case, pulmonary embolism in the left main pulmonary artery was located out of the FOV of DCTA because the left main pulmonary artery was retracted upwardly by fibrotic scar in the left upper lobe due to prior tuberculosis. There was no case of AAS and significant non-cardiac pathology excluded from the FOV of DCTA. AAS (n = 50) consisted of penetrating atherosclerotic ulcer (n = 7), intramural hematoma (n = 5) and aortic dissection (n = 38). Conclusion As isolated PE, AAS, and significant non-cardiac pathology outside of the DCTA FOV rarely occur, DCTA may replace TRO in the evaluation of patients with non-specific acute chest pain and a low pre-test probability of PE or aortic dissection

  6. Rarity of isolated pulmonary embolism and acute aortic syndrome occurring outside of the field of view of dedicated coronary CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Hwa Yeon; Song, In Sup (Dept. of Diagnostic Radiology Chung-Ang Univ. College of Medicine, Seoul (Korea, Republic of)); Yoo, Seung Min; Rho, Ji Young (Dept. of Diagnostic Radiology CHA Medical Univ. Hospital, Bundang (Korea, Republic of)), email: smyoo68@hanmail.net; Moon, Jae Youn; Kim, In Jai; Lim, Sang Wook; Sung, Jung Hoon; Cha, Dong Hun (Dept. of Cardiology CHA Medical Univ. Hospital, Bundang (Korea, Republic of)); White, Charles S. (Dept. of Diagnostic Radiology Univ. of Maryland, Baltimore (United States))

    2011-05-15

    Background Although triple rule-out CT angiography (TRO) to simultaneously evaluate acute coronary syndrome (ACS), pulmonary embolism (PE), and acute aortic syndrome (AAS) is increasingly used in many institutions, TRO is inevitably associated with increased radiation exposure due to extended z-axis coverage compared with dedicated coronary CT angiography (DCTA). Purpose To determine the frequency of exclusion of findings of AAS, PE, and significant incidental non-cardiac pathology that may be the cause of acute chest pain when using a restricted DCTA field of view (FOV). Material and Methods We retrospectively reviewed CT images and charts of 103 patients with acute PE and 50 patients with AAS. Either non-ECG gated dedicated pulmonary or aortic CT angiography was performed using 16- or 64-slice multidetector CT (MDCT). We analyzed the incidence of isolated PE, AAS, or significant non-cardiac pathology outside of DCTA FOV (i.e. from tracheal carina to the base of heart). Results There were two cases of isolated PE (2/103, 1.9%) excluded from the FOV of DCTA. One case of PE was isolated to the subsegmental pulmonary artery in the posterior segment of the right upper lobe. In the second case, pulmonary embolism in the left main pulmonary artery was located out of the FOV of DCTA because the left main pulmonary artery was retracted upwardly by fibrotic scar in the left upper lobe due to prior tuberculosis. There was no case of AAS and significant non-cardiac pathology excluded from the FOV of DCTA. AAS (n = 50) consisted of penetrating atherosclerotic ulcer (n = 7), intramural hematoma (n = 5) and aortic dissection (n = 38). Conclusion As isolated PE, AAS, and significant non-cardiac pathology outside of the DCTA FOV rarely occur, DCTA may replace TRO in the evaluation of patients with non-specific acute chest pain and a low pre-test probability of PE or aortic dissection

  7. High-resolution small field-of-view magnetic resonance image acquisition system using a small planar coil and a pneumatic manipulator in an open MRI scanner.

    Science.gov (United States)

    Miki, Kohei; Masamune, Ken

    2015-10-01

    Low-field open magnetic resonance imaging (MRI) is frequently used for performing image-guided neurosurgical procedures. Intraoperative magnetic resonance (MR) images are useful for tracking brain shifts and verifying residual tumors. However, it is difficult to precisely determine the boundary of the brain tumors and normal brain tissues because the MR image resolution is low, especially when using a low-field open MRI scanner. To overcome this problem, a high-resolution MR image acquisition system was developed and tested. An MR-compatible manipulator with pneumatic actuators containing an MR signal receiver with a small radiofrequency (RF) coil was developed. The manipulator had five degrees of freedom for position and orientation control of the RF coil. An 8-mm planar RF coil with resistance and inductance of 2.04 [Formula: see text] and 1.00 [Formula: see text] was attached to the MR signal receiver at the distal end of the probe. MR images of phantom test devices were acquired using the MR signal receiver and normal head coil for signal-to-noise ratio (SNR) testing. The SNR of MR images acquired using the MR signal receiver was 8.0 times greater than that of MR images acquired using the normal head coil. The RF coil was moved by the manipulator, and local MR images of a phantom with a 2-mm grid were acquired using the MR signal receiver. A wide field-of-view MR image was generated from a montage of local MR images. A small field-of-view RF system with a pneumatic manipulator was integrated in a low-field MRI scanner to allow acquisition of both wide field-of-view and high-resolution MR images. This system is promising for image-guided neurosurgery as it may allow brain tumors to be observed more clearly and removed precisely.

  8. Optical Design Using Small Dedicated Computers

    Science.gov (United States)

    Sinclair, Douglas C.

    1980-09-01

    Since the time of the 1975 International Lens Design Conference, we have developed a series of optical design programs for Hewlett-Packard desktop computers. The latest programs in the series, OSLO-25G and OSLO-45G, have most of the capabilities of general-purpose optical design programs, including optimization based on exact ray-trace data. The computational techniques used in the programs are similar to ones used in other programs, but the creative environment experienced by a designer working directly with these small dedicated systems is typically much different from that obtained with shared-computer systems. Some of the differences are due to the psychological factors associated with using a system having zero running cost, while others are due to the design of the program, which emphasizes graphical output and ease of use, as opposed to computational speed.

  9. Optimal usage of cone beam computed tomography system with different field of views in image guided radiotherapy (IGRT

    Directory of Open Access Journals (Sweden)

    Narayana Venkata Naga Madhusudhana Sresty

    2015-09-01

    Full Text Available Purpose: To find methods for optimal usage of XVI (X-ray volume imaging system in Elekta synergy linear accelerator with different field of views for same lesion in order to minimize patient dose due to imaging.Methods: 20 scans of 2 individual patients with ca sigmoid colon and ca lung were used in this study. Kilo voltage collimators with medium field of view were used as per the preset information. Images were reconstructed for another collimator with small field of view. The set up errors were evaluated with XVI software. Shift results of both methods were compared. Results: Variation in treatment set up errors with M20 and S20 collimators were ≤ 0.2 mm in translational and 0.30 in rotational shifts. Results showed almost equal translational and rotational shifts in both medium and small field of views with different collimators in all the scans. Visualization of target and surrounding structures were good enough and sufficient for XVI auto matching.Conclusion: Imaging with small field of view results less patient dose compared with medium or large field of views. It is Suggestible to use collimators with small field of view wherever possible. In this study, collimators with small field of view were sufficient for both patients though the preset information indicated medium field of view. But, it always depends on the area required for matching purpose. So, individual selection is important than preset information in the XVI system.

  10. Lensless imaging for wide field of view

    Science.gov (United States)

    Nagahara, Hajime; Yagi, Yasushi

    2015-02-01

    It is desirable to engineer a small camera with a wide field of view (FOV) because of current developments in the field of wearable cameras and computing products, such as action cameras and Google Glass. However, typical approaches for achieving wide FOV, such as attaching a fisheye lens and convex mirrors, require a trade-off between optics size and the FOV. We propose camera optics that achieve a wide FOV, and are at the same time small and lightweight. The proposed optics are a completely lensless and catoptric design. They contain four mirrors, two for wide viewing, and two for focusing the image on the camera sensor. The proposed optics are simple and can be simply miniaturized, since we use only mirrors for the proposed optics and the optics are not susceptible to chromatic aberration. We have implemented the prototype optics of our lensless concept. We have attached the optics to commercial charge-coupled device/complementary metal oxide semiconductor cameras and conducted experiments to evaluate the feasibility of our proposed optics.

  11. HIFI - a dedicated HIgh-FIeld diffraction and spectroscopy instrument

    International Nuclear Information System (INIS)

    Steffens, P.; Enderle, M.; Boehm, M.; Roux, S.

    2011-01-01

    The outstanding scientific impact of single-crystal neutron diffraction and spectroscopy in steady state vertical magnetic fields up to 15 T (17 T without dilution fringe) is reflected in numerous high-profile publications. Magnetic fields 30 T - 35 T in vertical geometry allow to address enigmatic questions without equivalence at lower fields. The constraints implied by such magnetic fields demand a specially designed dedicated instrument. Since the vertical field geometry is crucial for single-crystal diffraction as well as spectroscopy, the solid angle of scattered neutrons is restricted, and a high-flux reactor is best suited to host a corresponding instrument. We propose a world-wide unique versatile instrument for diffraction and spectroscopy in vertical steady fields of 30 T. (authors)

  12. Characterization of TLD-100 micro-cubes for use in small field dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Peña-Jiménez, Salvador, E-mail: zoid-9861@yahoo.com.mx; Gamboa-deBuen, Isabel, E-mail: gamboa@nucleares.unam.mx [Instituto de Ciencias Nucleares, Universidad Nacional Autónoma de México, Av. Universidad 3000, 04510 DF (Mexico); Lárraga-Gutiérrez, José Manuel, E-mail: jose.larraga.gtz@gmail.com, E-mail: amanda.garcia.g@gmail.com; García-Garduño, Olivia Amanda, E-mail: jose.larraga.gtz@gmail.com, E-mail: amanda.garcia.g@gmail.com [Laboratorio de Física Médica, Instituto Nacional de Neurología y Neurocirugía Manuel Velasco Suárez, Av. Insurgentes Sur 3877, 14269 DF (Mexico)

    2014-11-07

    At present there are no international regulations for the management of millimeter scale fields and there are no suggestions for a reference detector to perform the characterization and dose determination for unconventional radiation beams (small fields) so that the dosimetry of small fields remains an open research field worldwide because these fields are used in radiotherapy treatments. Sensitivity factors and reproducibility of TLD-100 micro-cubes (1×1×1 mm3) were determinate irradiating the dosimeters with a 6 MV beam in a linear accelerator dedicated to radiosurgery at the Instituto Nacional de Neurología y Neurocirugía (INNN). Thermoluminescent response as a function of dose was determined for doses in water between 0.5 and 3 Gy and two field sizes (2×2 cm2 and 10×10 cm2). It was found that the response is linear over the dose range studied and it does not depend on field size.

  13. Sub-millimetre DOI detector based on monolithic LYSO and digital SiPM for a dedicated small-animal PET system

    International Nuclear Information System (INIS)

    Marcinkowski, Radosław; Mollet, Pieter; Van Holen, Roel; Vandenberghe, Stefaan

    2016-01-01

    The mouse model is widely used in a vast range of biomedical and preclinical studies. Thanks to the ability to detect and quantify biological processes at the molecular level in vivo, PET has become a well-established tool in these investigations. However, the need to visualize and quantify radiopharmaceuticals in anatomic structures of millimetre or less requires good spatial resolution and sensitivity from small-animal PET imaging systems. In previous work we have presented a proof-of-concept of a dedicated high-resolution small-animal PET scanner based on thin monolithic scintillator crystals and Digital Photon Counter photosensor. The combination of thin monolithic crystals and MLE positioning algorithm resulted in an excellent spatial resolution of 0.7 mm uniform in the entire field of view (FOV). However, the limitation of the scanner was its low sensitivity due to small thickness of the lutetium-yttrium oxyorthosilicate (LYSO) crystals (2 mm). Here we present an improved detector design for a small-animal PET system that simultaneously achieves higher sensitivity and sustains a sub-millimetre spatial resolution. The proposed detector consists of a 5 mm thick monolithic LYSO crystal optically coupled to a Digital Photon Counter. Mean nearest neighbour (MNN) positioning combined with depth of interaction (DOI) decoding was employed to achieve sub-millimetre spatial resolution. To evaluate detector performance the intrinsic spatial resolution, energy resolution and coincidence resolving time (CRT) were measured. The average intrinsic spatial resolution of the detector was 0.60 mm full-width-at-half-maximum (FWHM). A DOI resolution of 1.66 mm was achieved. The energy resolution was 23% FWHM at 511 keV and CRT of 529 ps were measured. The improved detector design overcomes the sensitivity limitation of the previous design by increasing the nominal sensitivity of the detector block and retains an excellent intrinsic spatial resolution. (paper)

  14. Low energy microcolumn for large field view inspection

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Young Chul [Department of Optometry, Eulji University, 212 Yangji-dong, Sujeong-gu, Seongnam-si, Gyeonggi-do 461-713 (Korea, Republic of); Ahn, Seung-Joon; Oh, Tae-Sik; Kim, Dae-Wook [Department of Nanoscience, Sun Moon University 100 Kalsan-ri, Tangjeong-myun, Asan-si, Chungnam 336-708 (Korea, Republic of); Kim, Ho-Seob, E-mail: hskim3@sunmoon.ac.kr [Department of Nanoscience, Sun Moon University 100 Kalsan-ri, Tangjeong-myun, Asan-si, Chungnam 336-708 (Korea, Republic of); Jang, Won Kweon [Division of Electronic, Computer and Communication Engineering, Hanseo University 360 DaeKook-ri, Haemi-myun, Seosan-si, Chungnam 356-706 (Korea, Republic of)

    2011-12-15

    Since the development of microcolumn system, it attracted much attention because multiple microcolumns can be assembled into arrayed form, which is expected to generate multiple electron beams and overcome the disadvantage of electron beam inspection equipments, low throughput . However, it is not easy to apply a microcolumn to the practical inspection or testing equipment since its scanning area is too small. Even if the arrayed operation using multiple microcolumns can overcome this limit, it requires complicated supporting systems and related technologies to operate a number of microcolumns simultaneously. Therefore, we tried to modify microcolumn design itself so that it can have a large field of view. In this work, two kinds of modified columns will be suggested and the preliminary results showing their performance of scanning large area will be discussed. -- Highlights: Black-Right-Pointing-Pointer Two types of microcolumn designs to achieve a large field of view are fabricated. Black-Right-Pointing-Pointer Field of view of a microcolumn increases linearly with the working distance. Black-Right-Pointing-Pointer New designed microcolumns can be developed as a low energy column system for large view inspections.

  15. Development of a volumetric projection technique for the digital evaluation of field of view.

    Science.gov (United States)

    Marshall, Russell; Summerskill, Stephen; Cook, Sharon

    2013-01-01

    Current regulations for field of view requirements in road vehicles are defined by 2D areas projected on the ground plane. This paper discusses the development of a new software-based volumetric field of view projection tool and its implementation within an existing digital human modelling system. In addition, the exploitation of this new tool is highlighted through its use in a UK Department for Transport funded research project exploring the current concerns with driver vision. Focusing specifically on rearwards visibility in small and medium passenger vehicles, the volumetric approach is shown to provide a number of distinct advantages. The ability to explore multiple projections of both direct vision (through windows) and indirect vision (through mirrors) provides a greater understanding of the field of view environment afforded to the driver whilst still maintaining compatibility with the 2D projections of the regulatory standards. Field of view requirements for drivers of road vehicles are defined by simplified 2D areas projected onto the ground plane. However, driver vision is a complex 3D problem. This paper presents the development of a new software-based 3D volumetric projection technique and its implementation in the evaluation of driver vision in small- and medium-sized passenger vehicles.

  16. MediSPECT: Single photon emission computed tomography system for small field of view small animal imaging based on a CdTe hybrid pixel detector

    International Nuclear Information System (INIS)

    Accorsi, R.; Autiero, M.; Celentano, L.

    2007-01-01

    We describe MediSPECT, a new scanner developed at University and INFN Napoli, for SPECT studies on small animals with a small field of view (FOV) and high spatial resolution. The CdTe pixel detector (a 256x256 matrix of 55 μm square pixels) operating in single photon counting for detection of gamma-rays with low and medium energy (e.g. 125 I, 27-35 keV, 99m Tc, 140 keV), is bump bonded to the Medipix2 readout chip. The FOV of the MediSPECT scanner with a coded aperture mask collimator ranges from 6.3 mm (system spatial resolution 110 μm at 27-35 keV) to 24.3 mm. With a 0.30 mm pinhole the FOV ranges from 2.4 to 29 mm (where the system spatial resolution is 1.0 mm at 27-35 keV and 2.0 mm at 140 keV). MediSPECT will be used for in vivo imaging of small organs or tissue structures in mouse, e.g., brain, thyroid, heart or tumor

  17. Design, manufacturing and testing of a four-mirror telescope with a wide field of view

    Science.gov (United States)

    Gloesener, P.; Wolfs, F.; Lemagne, F.; Cola, M.; Flebus, C.; Blanchard, G.; Kirschner, V.

    2017-11-01

    Regarding Earth observation missions, it has become unnecessary to point out the importance of making available wide field of view optical instruments for the purpose of spectral imaging. Taking advantage of the pushbroom instrument concept with its linear field across the on-ground track, it is in particular relevant to consider front-end optical configurations that involve an all-reflective system presenting inherent and dedicated advantages such as achromaticity, unobscuration and compactness, while ensuring the required image quality over the whole field. The attractiveness of the concept must be balanced with respect to the state-of-the-art mirror manufacturing technologies as the need for fast, broadband and wide field systems increases the constraints put on the feasibility of each individual component. As part of an ESTEC contract, AMOS designed, manufactured and tested a breadboard of a four-mirror wide field telescope for typical Earth observation superspectral missions. The initial purpose of the development was to assess the feasibility of a telecentric spaceborne three-mirror system covering an unobscured rectangular field of view of 26 degrees across track (ACT) by 6 degrees along track (ALT) with a f-number of 3.5 and a focal length of 500 mm and presenting an overall image quality better than 100 nm RMS wavefront error within the whole field.

  18. LauncherOne: Virgin Orbit's Dedicated Launch Vehicle for Small Satellites & Impact to the Space Enterprise Vision

    Science.gov (United States)

    Vaughn, M.; Kwong, J.; Pomerantz, W.

    Virgin Orbit is developing a space transportation service to provide an affordable, reliable, and responsive dedicated ride to orbit for smaller payloads. No longer will small satellite users be forced to make a choice between accepting the limitations of flight as a secondary payload, paying dramatically more for a dedicated launch vehicle, or dealing with the added complexity associated with export control requirements and international travel to distant launch sites. Virgin Orbit has made significant progress towards first flight of a new vehicle that will give satellite developers and operators a better option for carrying their small satellites into orbit. This new service is called LauncherOne (See the figure below). LauncherOne is a two stage, air-launched liquid propulsion (LOX/RP) rocket. Air launched from a specially modified 747-400 carrier aircraft (named “Cosmic Girl”), this system is designed to conduct operations from a variety of locations, allowing customers to select various launch azimuths and increasing available orbital launch windows. This provides small satellite customers an affordable, flexible and dedicated option for access to space. In addition to developing the LauncherOne vehicle, Virgin Orbit has worked with US government customers and across the new, emerging commercial sector to refine concepts for resiliency, constellation replenishment and responsive launch elements that can be key enables for the Space Enterprise Vision (SEV). This element of customer interaction is being led by their new subsidiary company, VOX Space. This paper summarizes technical progress made on LauncherOne in the past year and extends the thinking of how commercial space, small satellites and this new emerging market can be brought to bear to enable true space system resiliency.

  19. Useful field of view test.

    Science.gov (United States)

    Wood, Joanne M; Owsley, Cynthia

    2014-01-01

    The useful field of view test was developed to reflect the visual difficulties that older adults experience with everyday tasks. Importantly, the useful field of view test (UFOV) is one of the most extensively researched and promising predictor tests for a range of driving outcomes measures, including driving ability and crash risk as well as other everyday tasks. Currently available commercial versions of the test can be administered using personal computers; these measure the speed of visual processing for rapid detection and localization of targets under conditions of divided visual attention and in the presence and absence of visual clutter. The test is believed to assess higher-order cognitive abilities, but performance also relies on visual sensory function because in order for targets to be attended to, they must be visible. The format of the UFOV has been modified over the years; the original version estimated the spatial extent of useful field of view, while the latest version measures visual processing speed. While deficits in the useful field of view are associated with functional impairments in everyday activities in older adults, there is also emerging evidence from several research groups that improvements in visual processing speed can be achieved through training. These improvements have been shown to reduce crash risk, and can have a positive impact on health and functional well-being, with the potential to increase the mobility and hence the independence of older adults. © 2014 S. Karger AG, Basel

  20. Design and evaluation of the MAMMI dedicated breast PET

    International Nuclear Information System (INIS)

    Moliner, L.; González, A. J.; Soriano, A.; Sánchez, F.; Correcher, C.; Orero, A.; Carles, M.; Vidal, L. F.; Barberá, J.; Caballero, L.; Seimetz, M.; Vázquez, C.; Benlloch, J. M.

    2012-01-01

    Purpose: A breast dedicated positron emission tomography (PET) scanner has been developed based on monolithic LYSO crystals coupled to position sensitive photomultiplier tubes (PSPMTs). In this study, we describe the design of the PET system and report on its performance evaluation. Methods: MAMMI is a breast PET scanner based on monolithic LYSO crystals. It consists of 12 compact modules with a transaxial field of view (FOV) of 170 mm in diameter and 40 mm axial FOV that translates to cover up to 170 mm. The patient lies down in a prone position that facilitates maximum breast elongation. Quantitative performance analysis of the calculated method for the attenuation correction specifically developed for MAMMI, and based on PET image segmentation, has also been conducted in this evaluation. In order to fully determine the MAMMI prototype's performance, we have adapted the measurements suggested for National Electrical Manufacturers Association (NEMA) NU 2-2007 and NU 4-2008 protocol tests, as they are defined for whole-body and small animal PET scanners, respectively. Results: Spatial resolutions of 1.6, 1.8, and 1.9 mm were measured in the axial, radial, and tangential directions, respectively. A scatter fraction of 20.8% was obtained and the maximum NEC was determined to be 25 kcps at 44 MBq. The average sensitivity of the system was observed to be 1% for an energy window of (250 keV–750 keV) and a maximum absolute sensitivity of 1.8% was measured at the FOV center. Conclusions: The overall performance of the MAMMI reported on this evaluation quantifies its ability to produce high quality PET images. Spatial resolution values below 3 mm were measured in most of the FOV. Only the radial component of spatial resolution exceeds the 3 mm at radial positions larger than 60 mm. This study emphasizes the need for standardized testing methodologies for dedicated breast PET systems similar to NEMA standards for whole-body and small animal PET scanners.

  1. Small Field of View Scintimammography Gamma Camera Integrated to a Stereotactic Core Biopsy Digital X-ray System

    Energy Technology Data Exchange (ETDEWEB)

    Andrew Weisenberger; Fernando Barbosa; T. D. Green; R. Hoefer; Cynthia Keppel; Brian Kross; Stanislaw Majewski; Vladimir Popov; Randolph Wojcik

    2002-10-01

    A small field of view gamma camera has been developed for integration with a commercial stereotactic core biopsy system. The goal is to develop and implement a dual-modality imaging system utilizing scintimammography and digital radiography to evaluate the reliability of scintimammography in predicting the malignancy of suspected breast lesions from conventional X-ray mammography. The scintimammography gamma camera is a custom-built mini gamma camera with an active area of 5.3 cm /spl times/ 5.3 cm and is based on a 2 /spl times/ 2 array of Hamamatsu R7600-C8 position-sensitive photomultiplier tubes. The spatial resolution of the gamma camera at the collimator surface is < 4 mm full-width at half-maximum and a sensitivity of /spl sim/ 4000 Hz/mCi. The system is also capable of acquiring dynamic scintimammographic data to allow for dynamic uptake studies. Sample images of preliminary clinical results are presented to demonstrate the performance of the system.

  2. Breast-specific gamma-imaging: molecular imaging of the breast using 99mTc-sestamibi and a small-field-of-view gamma-camera.

    Science.gov (United States)

    Jones, Elizabeth A; Phan, Trinh D; Blanchard, Deborah A; Miley, Abbe

    2009-12-01

    Breast-specific gamma-imaging (BSGI), also known as molecular breast imaging, is breast scintigraphy using a small-field-of-view gamma-camera and (99m)Tc-sestamibi. There are many different types of breast cancer, and many have characteristics making them challenging to detect by mammography and ultrasound. BSGI is a cost-effective, highly sensitive and specific technique that complements other imaging modalities currently being used to identify malignant lesions in the breast. Using the current Society of Nuclear Medicine guidelines for breast scintigraphy, Legacy Good Samaritan Hospital began conducting BSGI, breast scintigraphy with a breast-optimized gamma-camera. In our experience, optimal imaging has been conducted in the Breast Center by a nuclear medicine technologist. In addition, the breast radiologists read the BSGI images in correlation with the mammograms, ultrasounds, and other imaging studies performed. By modifying the current Society of Nuclear Medicine protocol to adapt it to the practice of breast scintigraphy with these new systems and by providing image interpretation in conjunction with the other breast imaging studies, our center has found BSGI to be a valuable adjunctive procedure in the diagnosis of breast cancer. The development of a small-field-of-view gamma-camera, designed to optimize breast imaging, has resulted in improved detection capabilities, particularly for lesions less than 1 cm. Our experience with this procedure has proven to aid in the clinical work-up of many of our breast patients. After reading this article, the reader should understand the history of breast scintigraphy, the pharmaceutical used, patient preparation and positioning, imaging protocol guidelines, clinical indications, and the role of breast scintigraphy in breast cancer diagnosis.

  3. III International Conference on Small Angle Neutron Scattering dedicated to the 80 anniversary of Yu.M. Ostanevich

    International Nuclear Information System (INIS)

    2017-01-01

    Preface “Among the many well-known fundamental and applied consequences of neutron discovery, one of the first was the emergence of structural neutron diffraction - one of the methods for studying the spatial structure of condensed matter at the atomic level. Investigating the dynamics of biological macromolecules by neutron diffraction methods is an area that is almost untouched. We believe that also in this direction one should expect rapid progress.” Yu.M.Ostanevich and I.N.Serdyuk Uspekhi Fizicheskih Nauk (1982) More than 30 years after Ostanevich and Serdyuk reviewed the then 50 years from the neutron discovery, we are happy to support their statement and prediction by reporting on the further progress in the field of neutron scattering research. Frank Laboratory of Neutron Physics has organized the III International Conference on Small Angle Neutron Scattering (YuMO2016) that was – not coincidently – dedicated to the 80th anniversary of Ostanevich. Yuriy Mechislavovich Ostanevich (1936–1992) has had a determinative and crucial contribution to the construction of spectrometers at the pulsed reactor IBR in Dubna, Russia. He contributed in particular to the development of time-of-flight small-angle neutron scattering (SANS) technique, and the selection of advanced scientific areas for its application. The SANS instrument at the IBR-2 reactor is called YuMO in his honour. The Ostanevich’s leadership and outstanding scientific achievements in SANS studies of polyelectrolytes, small molecules, fractals, metallic glasses, macromolecules, polymers, etc., were recognized also by a number of awards including the State Prize of the Russian Federation in 2000. To this end of course, we should not forget mentioning the contribution of close collaborators of Ostanevich: Laszlo Cser, Josef Plestil as well as Alexander Kunchenko, Vadim Bezzabotnov and Nikolay Gorski. The YuMO2016 conference focused on providing opportunities to discuss various possibilities of

  4. Refined adaptive optics simulation with wide field of view for the E-ELT

    International Nuclear Information System (INIS)

    Chebbo, Manal

    2012-01-01

    Refined simulation tools for wide field AO systems (such as MOAO, MCAO or LTAO) on ELTs present new challenges. Increasing the number of degrees of freedom (scales as the square of the telescope diameter) makes the standard simulation's codes useless due to the huge number of operations to be performed at each step of the Adaptive Optics (AO) loop process. This computational burden requires new approaches in the computation of the DM voltages from WFS data. The classical matrix inversion and the matrix vector multiplication have to be replaced by a cleverer iterative resolution of the Least Square or Minimum Mean Square Error criterion (based on sparse matrices approaches). Moreover, for this new generation of AO systems, concepts themselves will become more complex: data fusion coming from multiple Laser and Natural Guide Stars (LGS / NGS) will have to be optimized, mirrors covering all the field of view associated to dedicated mirrors inside the scientific instrument itself will have to be coupled using split or integrated tomography schemes, differential pupil or/and field rotations will have to be considered, etc. All these new entries should be carefully simulated, analysed and quantified in terms of performance before any implementation in AO systems. For those reasons I developed, in collaboration with the ONERA, a full simulation code, based on iterative solution of linear systems with many parameters (use of sparse matrices). On this basis, I introduced new concepts of filtering and data fusion (LGS / NGS) to effectively manage modes such as tip, tilt and defocus in the entire process of tomographic reconstruction. The code will also eventually help to develop and test complex control laws (Multi-DM and multi-field) who have to manage a combination of adaptive telescope and post-focal instrument including dedicated deformable mirrors. The first application of this simulation tool has been studied in the framework of the EAGLE multi-object spectrograph

  5. 3D absorbed dose calculation with GATE Monte Carlo simulation for the image-guided radiation therapy dedicated to the small animal

    International Nuclear Information System (INIS)

    Noblet, Caroline

    2014-01-01

    Innovating irradiators dedicated to small animal allow to mimic clinical treatments in image-guided radiation therapy. Clinical practice is scaled down to the small animal by reducing beam dimensions (from cm to mm) and energy (from MeV to keV). Millimeter medium energy beams ( [fr

  6. Various dedicated imaging systems for routine nuclear medical applications

    International Nuclear Information System (INIS)

    Bela Kari; Tamas Gyorke; Erno Mako; Laszlo Nagy; Jozsef Turak; Oszkar Partos

    2004-01-01

    eliminates the patient motion during the acquisition. For the period of the prototype test (the last half year) under clinical circumstances more than 400 various nuclear cardiac studies have been acquired and evaluated the obtained results show extraordinary promises for this unique dedicated equipment in the future functional cardiology. In case of thyroid images, where the 1:1 projection and the imaged size reproducibility is extremely important through the patient follow up procedures the parallel long septa so called 'butterfly' like or thyroid shape collimator arrangement together with high intrinsic resolution(<2.5 mm) Small Field Of View (SFOV) detector(<240 mm detector size) delivers the optimal solution.It is also possible to extend the application field of this SFOV planar gamma camera for any kind of functional 2D pediatric, cardiac and small animal research studies by applying regular formed LEHR or LEAP collimators. The measured 2D Point Spread Function(PSF) or in Fourier space the Modulation Transfer Function (MTF) show high stationary and linearity within tbe applied FOV in such object thickness. Consequently, larger part of the non-correlated noises can be eliminated by direct measured MTF based restoration filtering method free of artifact, resulting additional app. 10-12% improvement in spatial resolution and 12/15% in contrast. The energy resolution is <9.5% on Tc-99m photo-peak for all the above mentioned detectors (NaI(T1) scintillation detectors) providing better potential scatter elimination possibility than usual. The physical and technical performances of the dedicated imaging equipments were tested and measured by internationally validated (Jascsak, Capintec, Biodex....) and self made (point sources, line sources, thyroid...) phantoms. Both human studies and physical as well as anatomical phantom measurements showed highly correlated and consistent results. (authors)

  7. Image quality of grating target in model eye when viewed through a small-aperture corneal inlay.

    Science.gov (United States)

    Inoue, Makoto; Bissen-Miyajima, Hiroko; Arai, Hiroyuki; Noda, Toru; Ohnuma, Kazuhiko; Hirakata, Akito

    2014-07-01

    To evaluate the quality of the image of a grating target placed in a model eye and viewed through a small-aperture corneal inlay. Kyorin Eye Center, Tokyo, Japan. Experimental study. A Kamra corneal inlay was placed on the anterior surface of a fluid-filled model eye, and a United States Air Force target and a calibrated scale were placed on the inner surface of the model eye. With a flat contact lens or a contact or noncontact wide-angle viewing system, the contrast of the grating images and the field of view through the inlay were compared with those without the inlay. A blurred dark ring was observed with the flat contact lens and MiniQuad wide-viewing contact lens in the model eye with the inlay. The contrast of the gratings was significantly decreased at 16 cycles/mm (P=.028), 32 cycles/mm (P=.046), and 64 cycles/mm (P=.015). With the Resight noncontact wide-angle viewing system, the field of view was reduced from 62 degrees to 32 degrees when the front lens was at 7.0 mm and slightly reduced from 75 degrees to 62 degrees at 5.0 mm with the inlay. The contrast of grating images observed through the inlay was significantly reduced when viewed with the flat contact lens. The field of view through the wide-angle viewing system was also altered. However, the noncontact wide-angle viewing system may be recommended for vitreous surgeries in eyes with the inlay by adjusting the distance of the front lens from the cornea. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2014 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  8. SU-F-T-445: Effect of Triaxial Cables and Microdetectors in Small Field Dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Das, I; Andersen, A [Indiana University- School of Medicine, Indianapolis, IN (United States)

    2016-06-15

    Purpose: Advances in radiation treatment especially with smaller fields used in SRS, Gamma knife, Tomotherapy, Cyberknife, and IMRT, require a high degree of precision especially with microdetectors for small field dosimetry (Das et al, Med Ph, 35, 206, 2008; Alfonso et al, Med Phys, 35, 5179, 2008). Due to small signal, the triaxial cable becomes critical in terms of signal to noise ratio (SNR) which is studied with microdetectors. Methods: Six high quality triaxial cables, 9.1 meters long from different manufacturers without any defects were acquired along with 5 most popular microdetectors (microdiamond, plastic scintillators, SRS-diode, edge-diode and pinpoint). A dedicated electrometer was used for each combination except W1 which has its own supermax electrometer. A 6MV photon beam from Varian True beam with 100 MU at a 600 MU/min was used. Measurements were made at a depth of 5 cm in water phantom. Field sizes were varied from 0.5 cm to 10 cm square fields. Readings were taken with combination of cables and microdetectors. Results: Signal is dependent on the quality of the connectors, cables and types of microdetector. The readings varied from nC to pC depending on the type of microdetector. The net signal, S, (Sc-Sn), where Sc is signal with chamber and Sn is without chamber is a linear function of sensitive volume, v; (S = α+β•V), where α and β are constants. The standard deviation (SD) in 3 sets of reading with each combination of cable-detector was extremely low <0.02%. As expected the SD is higher in small fields (<3cm). Maximum estimated error was only ±0.2% in cables-detector combinations. Conclusion: The choice of cables has relatively small effect (±0.2%) with microdosimeter and should be accounted in overall error estimation in k value that is needed to convert ratio of reading to dose in small field dosimetry.

  9. SU-F-T-445: Effect of Triaxial Cables and Microdetectors in Small Field Dosimetry

    International Nuclear Information System (INIS)

    Das, I; Andersen, A

    2016-01-01

    Purpose: Advances in radiation treatment especially with smaller fields used in SRS, Gamma knife, Tomotherapy, Cyberknife, and IMRT, require a high degree of precision especially with microdetectors for small field dosimetry (Das et al, Med Ph, 35, 206, 2008; Alfonso et al, Med Phys, 35, 5179, 2008). Due to small signal, the triaxial cable becomes critical in terms of signal to noise ratio (SNR) which is studied with microdetectors. Methods: Six high quality triaxial cables, 9.1 meters long from different manufacturers without any defects were acquired along with 5 most popular microdetectors (microdiamond, plastic scintillators, SRS-diode, edge-diode and pinpoint). A dedicated electrometer was used for each combination except W1 which has its own supermax electrometer. A 6MV photon beam from Varian True beam with 100 MU at a 600 MU/min was used. Measurements were made at a depth of 5 cm in water phantom. Field sizes were varied from 0.5 cm to 10 cm square fields. Readings were taken with combination of cables and microdetectors. Results: Signal is dependent on the quality of the connectors, cables and types of microdetector. The readings varied from nC to pC depending on the type of microdetector. The net signal, S, (Sc-Sn), where Sc is signal with chamber and Sn is without chamber is a linear function of sensitive volume, v; (S = α+β•V), where α and β are constants. The standard deviation (SD) in 3 sets of reading with each combination of cable-detector was extremely low <0.02%. As expected the SD is higher in small fields (<3cm). Maximum estimated error was only ±0.2% in cables-detector combinations. Conclusion: The choice of cables has relatively small effect (±0.2%) with microdosimeter and should be accounted in overall error estimation in k value that is needed to convert ratio of reading to dose in small field dosimetry.

  10. Musculoskeletal MRI: dedicated systems

    International Nuclear Information System (INIS)

    Masciocchi, C.; Barile, A.; Satragno, L.

    2000-01-01

    The ''dedicated'' MRI units have characteristics of high diagnostic accuracy and lower installation and management costs as compared with whole-body systems. The dedicated MRI units are easy to install. The low weight allows their installation also under unfavorable circumstances. In a dedicated system cost-effectiveness and ease of installation must be accompanied by the capability of providing high-quality images. In our experience, the high number of examinations performed, the most part of which provided with the surgical controls, allowed an accurate evaluation of the diagnostic potentialities of the dedicated magnet. We were not able to perform the examinations in only 3 % of cases due to the physical shape of the patient and the clinical condition of the patient which may hinder the correct positioning of the limb. The overlapping of the diagnostic accuracy of the E-scan and Artoscan units in the study of the lower limbs, compared with whole-body units and surgery, prompted us to exploit the potentialities of the E-Scan in the study of the shoulder. We had a good correlation between E-Scan, whole-body units, and surgical findings, which confirmed the high diagnostic accuracy of the dedicated system. In conclusion, in our experience carried out in the musculoskeletal system, the dedicated magnets showed promising results. Their diagnostic reliability and utility was comparable to that obtained from conventional units operating at higher magnetic fields. (orig.)

  11. Spectral distribution of particle fluence in small field detectors and its implication on small field dosimetry.

    Science.gov (United States)

    Benmakhlouf, Hamza; Andreo, Pedro

    2017-02-01

    Correction factors for the relative dosimetry of narrow megavoltage photon beams have recently been determined in several publications. These corrections are required because of the several small-field effects generally thought to be caused by the lack of lateral charged particle equilibrium (LCPE) in narrow beams. Correction factors for relative dosimetry are ultimately necessary to account for the fluence perturbation caused by the detector. For most small field detectors the perturbation depends on field size, resulting in large correction factors when the field size is decreased. In this work, electron and photon fluence differential in energy will be calculated within the radiation sensitive volume of a number of small field detectors for 6 MV linear accelerator beams. The calculated electron spectra will be used to determine electron fluence perturbation as a function of field size and its implication on small field dosimetry analyzed. Fluence spectra were calculated with the user code PenEasy, based on the PENELOPE Monte Carlo system. The detectors simulated were one liquid ionization chamber, two air ionization chambers, one diamond detector, and six silicon diodes, all manufactured either by PTW or IBA. The spectra were calculated for broad (10 cm × 10 cm) and narrow (0.5 cm × 0.5 cm) photon beams in order to investigate the field size influence on the fluence spectra and its resulting perturbation. The photon fluence spectra were used to analyze the impact of absorption and generation of photons. These will have a direct influence on the electrons generated in the detector radiation sensitive volume. The electron fluence spectra were used to quantify the perturbation effects and their relation to output correction factors. The photon fluence spectra obtained for all detectors were similar to the spectrum in water except for the shielded silicon diodes. The photon fluence in the latter group was strongly influenced, mostly in the low-energy region, by

  12. A technique for automatically extracting useful field of view and central field of view images.

    Science.gov (United States)

    Pandey, Anil Kumar; Sharma, Param Dev; Aheer, Deepak; Kumar, Jay Prakash; Sharma, Sanjay Kumar; Patel, Chetan; Kumar, Rakesh; Bal, Chandra Sekhar

    2016-01-01

    It is essential to ensure the uniform response of the single photon emission computed tomography gamma camera system before using it for the clinical studies by exposing it to uniform flood source. Vendor specific acquisition and processing protocol provide for studying flood source images along with the quantitative uniformity parameters such as integral and differential uniformity. However, a significant difficulty is that the time required to acquire a flood source image varies from 10 to 35 min depending both on the activity of Cobalt-57 flood source and the pre specified counts in the vendors protocol (usually 4000K-10,000K counts). In case the acquired total counts are less than the total prespecified counts, and then the vendor's uniformity processing protocol does not precede with the computation of the quantitative uniformity parameters. In this study, we have developed and verified a technique for reading the flood source image, remove unwanted information, and automatically extract and save the useful field of view and central field of view images for the calculation of the uniformity parameters. This was implemented using MATLAB R2013b running on Ubuntu Operating system and was verified by subjecting it to the simulated and real flood sources images. The accuracy of the technique was found to be encouraging, especially in view of practical difficulties with vendor-specific protocols. It may be used as a preprocessing step while calculating uniformity parameters of the gamma camera in lesser time with fewer constraints.

  13. A technique for automatically extracting useful field of view and central field of view images

    International Nuclear Information System (INIS)

    Pandey, Anil Kumar; Sharma, Param Dev; Aheer, Deepak; Kumar, Jay Prakash; Sharma, Sanjay Kumar; Patel, Chetan; Kumar, Rakesh; Bal, Chandra Sekhar

    2016-01-01

    It is essential to ensure the uniform response of the single photon emission computed tomography gamma camera system before using it for the clinical studies by exposing it to uniform flood source. Vendor specific acquisition and processing protocol provide for studying flood source images along with the quantitative uniformity parameters such as integral and differential uniformity. However, a significant difficulty is that the time required to acquire a flood source image varies from 10 to 35 min depending both on the activity of Cobalt-57 flood source and the pre specified counts in the vendors protocol (usually 4000K-10,000K counts). In case the acquired total counts are less than the total prespecified counts, and then the vendor's uniformity processing protocol does not precede with the computation of the quantitative uniformity parameters. In this study, we have developed and verified a technique for reading the flood source image, remove unwanted information, and automatically extract and save the useful field of view and central field of view images for the calculation of the uniformity parameters. This was implemented using MATLAB R2013b running on Ubuntu Operating system and was verified by subjecting it to the simulated and real flood sources images. The accuracy of the technique was found to be encouraging, especially in view of practical difficulties with vendor-specific protocols. It may be used as a preprocessing step while calculating uniformity parameters of the gamma camera in lesser time with fewer constraints

  14. Acknowledgements [3. international conference on small angle neutron scattering dedicated to the 80 anniversary of Yu.M. Ostanevich, Dubna (Russian Federation), 6-9 June 2016

    International Nuclear Information System (INIS)

    2017-01-01

    The Organizers of the III International Conference on Small Angle Neutron Scattering dedicated to the 80-th anniversary of Yu. M. Ostanevich, acknowledge the financial support from the Grants of the Governmental Plenipotentiary Representatives of Romania, Slovakia, Czech Republic, scientific projects of the Cooperation Programmes JINR-Romania. Special gratitude to the JINR and FLNP administration and staff is expressed. The conference is also dedicated to the 60th Anniversary of the Joint Institute for Nuclear Research, Dubna. (paper)

  15. Optical calibration protocol for an x-ray and optical multimodality tomography system dedicated to small-animal examination

    International Nuclear Information System (INIS)

    Da Silva, Anabela; Leabad, Mehdi; Driol, Clemence; Bordy, Thomas; Debourdeau, Mathieu; Dinten, Jean-Marc; Peltie, Philippe; Rizo, Philippe

    2009-01-01

    A small-animal multimodality tomography system dedicated to the coregistration of fluorescence optical signal and x-ray measurements has been developed in our laboratory. The purpose of such a system is to offer the possibility of getting in vivo anatomical and functional information simultaneously. Moreover, anatomical measurements can be used as a regularization factor to achieve more accurate reconstructions of the biodistribution of fluorochromes and to speed up treatment. A dedicated acquisition protocol has been established, and the methodology of the reconstruction of the three-dimensional distribution of the biomarkers under cylindrical geometry consistent with classic computed tomography has been implemented. A phantom study was conducted to evaluate and to fix the parameters for the coregistration. These test experiments were reproduced by considering anesthetized mice that had thin glass tubes containing fluorochromes inserted into their esophagus. The instrument is also used for an in vivo biological study conducted on mice with lung tumors, tagged with near-infrared optical probes (targeting probes such as Transferin-AlexaFluor750)

  16. About microlensing optical depth and rates for free-floating planets towards the Kepler's field of view

    International Nuclear Information System (INIS)

    Hafizi, M; Hamolli, L

    2012-01-01

    In this work we examine the possibility of observing microlensing events in the Kepler space observatory field of view, caused by brown dwarfs or free-floating planets. We calculate the optical depth towards the field of view of the Kepler satellite and the rate of these events based on latest results about mass distribution of astrophysical objects from brown dwarf down to Earth mass order. With the current data, the probability of such events is insignificant, due to the small number of stars observed by this instrument compared to other experiments devoted to the microlensing method. Nevertheless, this probability may increase significantly in the case of a higher presence of free-floating planets, whose number is poorly defined so far.

  17. Nonlinear gravitational self-force: Field outside a small body

    Science.gov (United States)

    Pound, Adam

    2012-10-01

    A small extended body moving through an external spacetime gαβ creates a metric perturbation hαβ, which forces the body away from geodesic motion in gαβ. The foundations of this effect, called the gravitational self-force, are now well established, but concrete results have mostly been limited to linear order. Accurately modeling the dynamics of compact binaries requires proceeding to nonlinear orders. To that end, I show how to obtain the metric perturbation outside the body at all orders in a class of generalized wave gauges. In a small buffer region surrounding the body, the form of the perturbation can be found analytically as an expansion for small distances r from a representative worldline. Given only a specification of the body’s multipole moments, the field obtained in the buffer region suffices to find the metric everywhere outside the body via a numerical puncture scheme. Following this procedure at first and second order, I calculate the field in the buffer region around an arbitrarily structured compact body at sufficiently high order in r to numerically implement a second-order puncture scheme, including effects of the body’s spin. I also define nth-order (local) generalizations of the Detweiler-Whiting singular and regular fields and show that in a certain sense, the body can be viewed as a skeleton of multipole moments.

  18. Quantitative investigation of a novel small field of view hybrid gamma camera (HGC) capability for sentinel lymph node detection

    Science.gov (United States)

    Lees, John E; Bugby, Sarah L; Jambi, Layal K; Perkins, Alan C

    2016-01-01

    Objective: The hybrid gamma camera (HGC) has been developed to enhance the localization of radiopharmaceutical uptake in targeted tissues during surgical procedures such as sentinel lymph node (SLN) biopsy. To assess the capability of the HGC, a lymph node contrast (LNC) phantom was constructed to simulate medical scenarios of varying radioactivity concentrations and SLN size. Methods: The phantom was constructed using two clear acrylic glass plates. The SLNs were simulated by circular wells of diameters ranging from 10 to 2.5 mm (16 wells in total) in 1 plate. The second plate contains four larger rectangular wells to simulate tissue background activity surrounding the SLNs. The activity used to simulate each SLN ranged between 4 and 0.025 MBq. The activity concentration ratio between the background and the activity injected in the SLNs was 1 : 10. The LNC phantom was placed at different depths of scattering material ranging between 5 and 40 mm. The collimator-to-source distance was 120 mm. Image acquisition times ranged from 60 to 240 s. Results: Contrast-to-noise ratio analysis and full-width-at-half-maximum (FWHM) measurements of the simulated SLNs were carried out for the images obtained. Over the range of activities used, the HGC detected between 87.5 and 100% of the SLNs through 20 mm of scattering material and 75–93.75% of the SLNs through 40 mm of scattering material. The FWHM of the detected SLNs ranged between 11.93 and 14.70 mm. Conclusion: The HGC is capable of detecting low accumulation of activity in small SLNs, indicating its usefulness as an intraoperative imaging system during surgical SLN procedures. Advances in knowledge: This study investigates the capability of a novel small-field-of-view (SFOV) HGC to detect low activity uptake in small SLNs. The phantom and procedure described are inexpensive and could be easily replicated and applied to any SFOV camera, to provide a comparison between systems with clinically relevant

  19. Dedicated radial ventriculography pigtail catheter

    Energy Technology Data Exchange (ETDEWEB)

    Vidovich, Mladen I., E-mail: miv@uic.edu

    2013-05-15

    A new dedicated cardiac ventriculography catheter was specifically designed for radial and upper arm arterial access approach. Two catheter configurations have been developed to facilitate retrograde crossing of the aortic valve and to conform to various subclavian, ascending aortic and left ventricular anatomies. The “short” dedicated radial ventriculography catheter is suited for horizontal ascending aortas, obese body habitus, short stature and small ventricular cavities. The “long” dedicated radial ventriculography catheter is suited for vertical ascending aortas, thin body habitus, tall stature and larger ventricular cavities. This new design allows for improved performance, faster and simpler insertion in the left ventricle which can reduce procedure time, radiation exposure and propensity for radial artery spasm due to excessive catheter manipulation. Two different catheter configurations allow for optimal catheter selection in a broad range of patient anatomies. The catheter is exceptionally stable during contrast power injection and provides equivalent cavity opacification to traditional femoral ventriculography catheter designs.

  20. Detection of small leakage combining dedicated Kalman filters and an extended version of the binary SPRT

    International Nuclear Information System (INIS)

    Racz, A.

    1991-12-01

    A new method is outlined for detection of soft reactor failures. The procedure is applicable when the failure can be described by an additive term (failure vector) in the measurement process of an observable dynamic system. A dedicated Kalman filter generates the innovation process for further testing. The innovation is investigated by a sequential hypothesis testing method. In order to avoid the computational difficulties related to sophisticated multiple hypothesis testing methods, an extended version of Walds's classical binary Sequential Probability Ratio Testing (SPRT) has been developed. The procedure is applied for the problem of (small) leakage detection in the feedwater system of nuclear power plants. Computer simulation results show that the method can recognize less than 1% relative water loss reliably. (author) 10 refs.; 5 figs.; 5 tabs

  1. Large field-of-view transmission line resonator for high field MRI

    DEFF Research Database (Denmark)

    Zhurbenko, Vitaliy; Johannesson, Kristjan Sundgaard; Boer, Vincent

    2016-01-01

    Transmission line resonators is often a preferable choice for coils in high field magnetic resonance imaging (MRI), because they provide a number of advantages over traditional loop coils. The size of such resonators, however, is limited to shorter than half a wavelength due to high standing wave....... Achieved magnetic field distribution is compared to the conventional transmission line resonator. Imaging experiments are performed using 7 Tesla MRI system. The developed resonator is useful for building coils with large field-of-view....

  2. Narrow Field of View Zenith Radiometer (NFOV) Handbook

    Energy Technology Data Exchange (ETDEWEB)

    Chiu, C; Marshak, A; Hodges, G; Barnard, JC; Schmelzer, J

    2008-11-01

    The two-channel narrow field-of-view radiometer (NFOV2) is a ground-based radiometer that looks straight up and measures radiance directly above the instrument at wavelengths of 673 and 870 nm. The field-of-view of the instrument is 1.2 degrees, and the sampling time resolution is one second. Measurements of the NFOV2 have been used to retrieve optical properties for overhead clouds that range from patchy to overcast. With a one-second sampling rate of the NFOV2, faster than almost any other ARM Climate Research Facility (ACRF) instrument, we are able, for the first time, to capture changes in cloud optical properties at the natural time scale of cloud evolution.

  3. Assessment of new small-field detectors against standard-field detectors for practical stereotactic beam data acquisition

    International Nuclear Information System (INIS)

    McKerracher, C.; Thwaites, D.I.

    1999-01-01

    Two new detectors (0.015 cm 3 ion chamber from PTW, 0.6 mm diameter diode from Scanditronix AB) designed specifically for use in small stereotactic fields were compared against similar, more routine, detectors (0.125 cm 3 ion chamber, parallel plate chamber, shielded and unshielded diodes and film). Percentage depth doses, tissue maximum ratios, off-axis ratios and relative output factors were compared for circular fields in the 40-12.5 mm diameter range, with a view to identifying the optimum detector for stereotactic beam data acquisition. Practical suggestions for beam data collection and analysis are made, with an emphasis on what is achievable practically in radiotherapy departments where the primary demand is to provide a routine service. No single detector was found to be ideal, and neither of the two new measurement devices had any significant advantages over more routine devices, in the situations measured. Although the new 0.015 cm 3 ion chamber was an improvement on a 0.125 cm 3 ion chamber in the measurement of profiles, it was still too large when compared with a diode. The new small diode had a low signal to noise ratio which made reliable data difficult to extract and its only advantage is possibly improved resolution in fields smaller than the range tested. The use of a larger unshielded diode is recommended for all measurements, with the additional cross-checking of data against at least one small ion chamber and film. A simple method of obtaining reliable output data from the detectors used is explained. (author)

  4. A system dedicated to the viewing and handling of tomographic images obtained by magnetic resonance

    International Nuclear Information System (INIS)

    Slaets, Joan F.W.; Almeida, Lirio O.B.; Traina, Agma J.M.

    1992-01-01

    The present work describes the development of a dedicated system to be used in visualization and manipulation of a MR images. The graphics environment as well as the tool kit were developed for the dedicated TMS34010 based hardware. The developed software offers a compact kernel with primitives to support the creation and manipulation windows and menus directly in 'C' language. This work is fundamental for the implementation of a user friendly interface build to operate and visualize tomographic images. This tools are essential for the selection an archiving of images planes as used in clinical applications. (author)

  5. Monte Carlo simulation of small field electron beams for small animal irradiation

    International Nuclear Information System (INIS)

    Lee, Chung-Chi; Chen, Ai-Mei; Tung, Chuan-Jong; Chao, Tsi-Chian

    2011-01-01

    The volume effect of detectors in the dosimetry of small fields for photon beams has been well studied due to interests in radiosurgery and small beamlets used in IMRT treatments; but there is still an unexplored research field for small electron beams used in small animal irradiation. This study proposes to use the BEAM Monte Carlo (MC) simulation to assess characteristics of small electron beams (4, 6, 14, 30 mm in diameter) with the kinetic energies of 6 and 18 MeV. Three factors influencing beam characteristics were studied (1) AE and ECUT settings, (2) photon jaw settings and (3) simulation pixel sizes. Study results reveal that AE/ECUT settings at 0.7 MeV are adequate for linear accelerator treatment head simulation, while 0.521 MeV is more favorable to be used for the phantom study. It is also demonstrated that voxel size setting at 1/4 of the simulation field width in all directions is sufficient to achieve accurate results. As for the photon jaw setting, it has great impact on the absolute output of different field size setting (i.e. output factor) but with minimum effect on the relative lateral distribution.

  6. Performance evaluation of a high resolution dedicated breast PET scanner

    Energy Technology Data Exchange (ETDEWEB)

    García Hernández, Trinitat, E-mail: mtrinitat@eresa.com; Vicedo González, Aurora; Brualla González, Luis; Granero Cabañero, Domingo [Department of Medical Physics, ERESA, Hospital General Universitario, Valencia 46014 (Spain); Ferrer Rebolleda, Jose; Sánchez Jurado, Raúl; Puig Cozar Santiago, Maria del [Department of Nuclear Medicine, ERESA, Hospital General Universitario, Valencia 46014 (Spain); Roselló Ferrando, Joan [Department of Medical Physics, ERESA, Hospital General Universitario, Valencia 46014 (Spain); Department of Physiology, University of Valencia, Valencia 46010 (Spain)

    2016-05-15

    Purpose: Early stage breast cancers may not be visible on a whole-body PET scan. To overcome whole-body PET limitations, several dedicated breast positron emission tomography (DbPET) systems have emerged nowadays aiming to improve spatial resolution. In this work the authors evaluate the performance of a high resolution dedicated breast PET scanner (Mammi-PET, Oncovision). Methods: Global status, uniformity, sensitivity, energy, and spatial resolution were measured. Spheres of different sizes (2.5, 4, 5, and 6 mm diameter) and various 18 fluorodeoxyglucose ({sup 18}F-FDG) activity concentrations were randomly inserted in a gelatine breast phantom developed at our institution. Several lesion-to-background ratios (LBR) were simulated, 5:1, 10:1, 20:1, 30:1, and 50:1. Images were reconstructed using different voxel sizes. The ability of experienced reporters to detect spheres was tested as a function of acquisition time, LBR, sphere size, and matrix reconstruction voxel size. For comparison, phantoms were scanned in the DbPET camera and in a whole body PET (WB-PET). Two patients who just underwent WB-PET/CT exams were imaged with the DbPET system and the images were compared. Results: The measured absolute peak sensitivity was 2.0%. The energy resolution was 24.0% ± 1%. The integral and differential uniformity were 10% and 6% in the total field of view (FOV) and 9% and 5% in the central FOV, respectively. The measured spatial resolution was 2.0, 1.9, and 1.7 mm in the radial, tangential, and axial directions. The system exhibited very good detectability for spheres ≥4 mm and LBR ≥10 with a sphere detection of 100% when acquisition time was set >3 min/bed. For LBR = 5 and acquisition time of 7 min the detectability was 100% for spheres of 6 mm and 75% for spheres of 5, 4, and 2.5 mm. Lesion WB-PET detectability was only comparable to the DbPET camera for lesion sizes ≥5 mm when acquisition time was >3 min and LBR > 10. Conclusions: The DbPET has a good

  7. Performance evaluation of a high resolution dedicated breast PET scanner

    International Nuclear Information System (INIS)

    García Hernández, Trinitat; Vicedo González, Aurora; Brualla González, Luis; Granero Cabañero, Domingo; Ferrer Rebolleda, Jose; Sánchez Jurado, Raúl; Puig Cozar Santiago, Maria del; Roselló Ferrando, Joan

    2016-01-01

    Purpose: Early stage breast cancers may not be visible on a whole-body PET scan. To overcome whole-body PET limitations, several dedicated breast positron emission tomography (DbPET) systems have emerged nowadays aiming to improve spatial resolution. In this work the authors evaluate the performance of a high resolution dedicated breast PET scanner (Mammi-PET, Oncovision). Methods: Global status, uniformity, sensitivity, energy, and spatial resolution were measured. Spheres of different sizes (2.5, 4, 5, and 6 mm diameter) and various 18 fluorodeoxyglucose ("1"8F-FDG) activity concentrations were randomly inserted in a gelatine breast phantom developed at our institution. Several lesion-to-background ratios (LBR) were simulated, 5:1, 10:1, 20:1, 30:1, and 50:1. Images were reconstructed using different voxel sizes. The ability of experienced reporters to detect spheres was tested as a function of acquisition time, LBR, sphere size, and matrix reconstruction voxel size. For comparison, phantoms were scanned in the DbPET camera and in a whole body PET (WB-PET). Two patients who just underwent WB-PET/CT exams were imaged with the DbPET system and the images were compared. Results: The measured absolute peak sensitivity was 2.0%. The energy resolution was 24.0% ± 1%. The integral and differential uniformity were 10% and 6% in the total field of view (FOV) and 9% and 5% in the central FOV, respectively. The measured spatial resolution was 2.0, 1.9, and 1.7 mm in the radial, tangential, and axial directions. The system exhibited very good detectability for spheres ≥4 mm and LBR ≥10 with a sphere detection of 100% when acquisition time was set >3 min/bed. For LBR = 5 and acquisition time of 7 min the detectability was 100% for spheres of 6 mm and 75% for spheres of 5, 4, and 2.5 mm. Lesion WB-PET detectability was only comparable to the DbPET camera for lesion sizes ≥5 mm when acquisition time was >3 min and LBR > 10. Conclusions: The DbPET has a good performance

  8. Commissioning and quality control of a dedicated wide bore 3T MRI simulator for radiotherapy planning

    Directory of Open Access Journals (Sweden)

    Aitang Xing

    2016-06-01

    Full Text Available Purpose: The purpose of this paper is to describe a practical approach to commissioning and quality assurance (QA of a dedicated wide-bore 3 Tesla (3T magnetic resonance imaging (MRI scanner for radiotherapy planning.Methods: A comprehensive commissioning protocol focusing on radiotherapy (RT specific requirements was developed and performed. RT specific tests included: uniformity characteristics of radio-frequency (RF coil, couch top attenuation, geometric distortion, laser and couch movement and an end-to-end radiotherapy treatment planning test. General tests for overall system performance and safety measurements were also performed.Results: The use of pre-scan based intensity correction increased the uniformity from 61.7% to 97% (body flexible coil, from 50% to 90% (large flexible coil and from 51% to 98% (small flexible coil. RT flat top couch decreased signal-to-noise ratio (SNR by an average of 42%. The mean and maximum geometric distortion was found to be 1.25 mm and 4.08 mm for three dimensional (3D corrected image acquisition, 2.07 mm and 7.88 mm for two dimensional (2D corrected image acquisition over 500 mm × 375 mm × 252 mm field of view (FOV. The accuracy of the laser and couch movement was less than ±1 mm. The standard deviation of registration parameters for the end-to-end test was less than 0.41 mm. An on-going QA program was developed to monitor the system’s performance.Conclusion: A number of RT specific tests have been described for commissioning and subsequent performance monitoring of a dedicated MRI simulator (MRI-Sim. These tests have been important in establishing and maintaining its operation for RT planning.

  9. An orbit determination algorithm for small satellites based on the magnitude of the earth magnetic field

    Science.gov (United States)

    Zagorski, P.; Gallina, A.; Rachucki, J.; Moczala, B.; Zietek, S.; Uhl, T.

    2018-06-01

    Autonomous attitude determination systems based on simple measurements of vector quantities such as magnetic field and the Sun direction are commonly used in very small satellites. However, those systems always require knowledge of the satellite position. This information can be either propagated from orbital elements periodically uplinked from the ground station or measured onboard by dedicated global positioning system (GPS) receiver. The former solution sacrifices satellite autonomy while the latter requires additional sensors which may represent a significant part of mass, volume, and power budget in case of pico- or nanosatellites. Hence, it is thought that a system for onboard satellite position determination without resorting to GPS receivers would be useful. In this paper, a novel algorithm for determining the satellite orbit semimajor-axis is presented. The methods exploit only the magnitude of the Earth magnetic field recorded onboard by magnetometers. This represents the first step toward an extended algorithm that can determine all orbital elements of the satellite. The method is validated by numerical analysis and real magnetic field measurements.

  10. The operator view of the Superconducting Cyclotron at LNS Catania

    International Nuclear Information System (INIS)

    Giove, D.; Cuttone, G.; Rovelli, A.

    1992-01-01

    The upper level of a distributed control system designed for the Superconducting Cyclotron (SC), will be discussed. In particular, we will present a detailed description of the operator view of this accelerator along with the tools for I/O points management, data representations, data archiving and retrieval. A dedicated program, developed by us, working under X-Window will be described as a starting point for a new man-machine interface approach in small laboratories opposed to the first industrial available packages. (author)

  11. Standoff Laser-Induced Breakdown Spectroscopy (LIBS) Using a Miniature Wide Field of View Spatial Heterodyne Spectrometer with Sub-Microsteradian Collection Optics.

    Science.gov (United States)

    Barnett, Patrick D; Lamsal, Nirmal; Angel, S Michael

    2017-04-01

    A spatial heterodyne spectrometer (SHS) is described for standoff laser-induced breakdown spectroscopy (LIBS) measurements. The spatial heterodyne LIBS spectrometer (SHLS) is a diffraction grating based interferometer with no moving parts that offers a very large field of view, high light throughput, and high spectral resolution in a small package. The field of view of the SHLS spectrometer is shown to be ∼1° in standoff LIBS measurements. In the SHLS system described here, the collection aperture was defined by the 10 mm diffraction gratings in the SHS and standoff LIBS measurements were made up to 20 m with no additional collection optics, corresponding to a collection solid angle of 0.2 μsr, or f/2000, and also using a small telescope to increase the collection efficiency. The use of a microphone was demonstrated to rapidly optimize laser focus for 20 m standoff LIBS measurements.

  12. Rotatable Small Permanent Magnet Array for Ultra-Low Field Nuclear Magnetic Resonance Instrumentation: A Concept Study.

    Science.gov (United States)

    Vogel, Michael W; Giorni, Andrea; Vegh, Viktor; Pellicer-Guridi, Ruben; Reutens, David C

    2016-01-01

    We studied the feasibility of generating the variable magnetic fields required for ultra-low field nuclear magnetic resonance relaxometry with dynamically adjustable permanent magnets. Our motivation was to substitute traditional electromagnets by distributed permanent magnets, increasing system portability. The finite element method (COMSOL®) was employed for the numerical study of a small permanent magnet array to calculate achievable magnetic field strength, homogeneity, switching time and magnetic forces. A manually operated prototype was simulated and constructed to validate the numerical approach and to verify the generated magnetic field. A concentric small permanent magnet array can be used to generate strong sample pre-polarisation and variable measurement fields for ultra-low field relaxometry via simple prescribed magnet rotations. Using the array, it is possible to achieve a pre-polarisation field strength above 100 mT and variable measurement fields ranging from 20-50 μT with 200 ppm absolute field homogeneity within a field-of-view of 5 x 5 x 5 cubic centimetres. A dynamic small permanent magnet array can generate multiple highly homogeneous magnetic fields required in ultra-low field nuclear magnetic resonance (NMR) and magnetic resonance imaging (MRI) instruments. This design can significantly reduce the volume and energy requirements of traditional systems based on electromagnets, improving portability considerably.

  13. Older Adult Multitasking Performance Using a Gaze-Contingent Useful Field of View.

    Science.gov (United States)

    Ward, Nathan; Gaspar, John G; Neider, Mark B; Crowell, James; Carbonari, Ronald; Kaczmarski, Hank; Ringer, Ryan V; Johnson, Aaron P; Loschky, Lester C; Kramer, Arthur F

    2018-03-01

    Objective We implemented a gaze-contingent useful field of view paradigm to examine older adult multitasking performance in a simulated driving environment. Background Multitasking refers to the ability to manage multiple simultaneous streams of information. Recent work suggests that multitasking declines with age, yet the mechanisms supporting these declines are still debated. One possible framework to better understand this phenomenon is the useful field of view, or the area in the visual field where information can be attended and processed. In particular, the useful field of view allows for the discrimination of two competing theories of real-time multitasking, a general interference account and a tunneling account. Methods Twenty-five older adult subjects completed a useful field of view task that involved discriminating the orientation of lines in gaze-contingent Gabor patches appearing at varying eccentricities (based on distance from the fovea) as they operated a vehicle in a driving simulator. In half of the driving scenarios, subjects also completed an auditory two-back task to manipulate cognitive workload, and during some trials, wind was introduced as a means to alter general driving difficulty. Results Consistent with prior work, indices of driving performance were sensitive to both wind and workload. Interestingly, we also observed a decline in Gabor patch discrimination accuracy under high cognitive workload regardless of eccentricity, which provides support for a general interference account of multitasking. Conclusion The results showed that our gaze-contingent useful field of view paradigm was able to successfully examine older adult multitasking performance in a simulated driving environment. Application This study represents the first attempt to successfully measure dynamic changes in the useful field of view for older adults completing a multitasking scenario involving driving.

  14. A comparative design view for accurate control of servos using a field programmable gate array

    International Nuclear Information System (INIS)

    Tickle, A J; Harvey, P K; Smith, J S; Wu, F; Buckle, J R

    2009-01-01

    An embedded system is a special-purpose computer system designed to perform one or a few dedicated functions. Altera DSP Builder presents designers and users with an alternate approach when creating their systems by employing a blockset similar to that already used in Simulink. The application considered in this paper is the design of a Pulse Width Modulation (PWM) system for use in stereo vision. PWM can replace a digital-to-analogue converter to control audio speakers, LED intensity, motor speed, and servo position. Rather than the conventional HDL coding approach this Simulink approach provides an easy understanding platform to the PWM design. This paper includes a comparison between two approaches regarding resource usage and flexibility etc. Included is how DSP Builder manipulates an onboard clock signal, in order to create the control pulses to the 'raw' coding of a PWM generator in VHDL. Both methods were shown to a selection of people and their views on which version they would subsequently use in their relative fields is discussed.

  15. Dedicated data recording video system for Spacelab experiments

    Science.gov (United States)

    Fukuda, Toshiyuki; Tanaka, Shoji; Fujiwara, Shinji; Onozuka, Kuniharu

    1984-04-01

    A feasibility study of video tape recorder (VTR) modification to add the capability of data recording etc. was conducted. This system is an on-broad system to support Spacelab experiments as a dedicated video system and a dedicated data recording system to operate independently of the normal operation of the Orbiter, Spacelab and the other experiments. It continuously records the video image signals with the acquired data, status and operator's voice at the same time on one cassette video tape. Such things, the crews' actions, animals' behavior, microscopic views and melting materials in furnace, etc. are recorded. So, it is expected that experimenters can make a very easy and convenient analysis of the synchronized video, voice and data signals in their post flight analysis.

  16. Virtual navigation performance: the relationship to field of view and prior video gaming experience.

    Science.gov (United States)

    Richardson, Anthony E; Collaer, Marcia L

    2011-04-01

    Two experiments examined whether learning a virtual environment was influenced by field of view and how it related to prior video gaming experience. In the first experiment, participants (42 men, 39 women; M age = 19.5 yr., SD = 1.8) performed worse on a spatial orientation task displayed with a narrow field of view in comparison to medium and wide field-of-view displays. Counter to initial hypotheses, wide field-of-view displays did not improve performance over medium displays, and this was replicated in a second experiment (30 men, 30 women; M age = 20.4 yr., SD = 1.9) presenting a more complex learning environment. Self-reported video gaming experience correlated with several spatial tasks: virtual environment pointing and tests of Judgment of Line Angle and Position, mental rotation, and Useful Field of View (with correlations between .31 and .45). When prior video gaming experience was included as a covariate, sex differences in spatial tasks disappeared.

  17. Influence of a small field-of-view size on the detection of coronary artery calcifications with MSCT: in vitro and in vivo study

    International Nuclear Information System (INIS)

    Mahnken, Andreas H.; Muehlenbruch, Georg; Das, Marco; Pohl, Saskia; Guenther, Rolf W.; Wildberger, Joachim E.; Koos, Ralf; Stanzel, Sven

    2006-01-01

    The purpose of this study is to asses the impact of small field-of-view (FOV) sizes on the detection of coronary artery calcifications using multislice-spiral computed tomography (MSCT). First, a static chest phantom containing calcium inserts was scanned 10 times using a standardized scan protocol. Secondly, 50 patients (28 male, 63.6±10.6 years) underwent cardiac MSCT using the same protocol. Images were reconstructed with three different FOV sizes (180 x 180, 220 x 220, 380 x 380 mm 2 ). Coronary calcium scoring and risk stratification were performed for each image series. In the phantom study, the Agatston score calculated with a FOV size of 180 x 180 mm 2 was 657.80±20.05. At a FOV of 220 x 220 mm 2 and 380 x 380 mm 2 , the corresponding values were 657.04±21.36 and 655.04±20.74, respectively. The corresponding values in the patient study were 541.65±869.87, 541.91±872.57 and 536.61±867.81. No statistically significant differences in the calcium score were found comparing different FOV sizes. Significantly more lesions (p=0.00149) were detected in the patient study. Comparing the different FOV sizes of 180 x 180 mm 2 and 220 x 220 mm 2 (380 x 380 mm 2 ), four (six) patients had to be assigned to different risk groups. The use of small FOV sizes resulted in an improved detection of coronary calcifications influencing the risk stratification for further cardiac events in MSCT coronary calcium scoring. (orig.)

  18. Stellarator fields with small PS current at small rotational transform

    International Nuclear Information System (INIS)

    Herrnegger, F.

    2001-01-01

    One aspect of the optimization concept of stellarators is the reduction of the normalized Pfirsch-Schlueter current density p arallel 2 / j p erpendikular 2 > 1/2 to a reasonable level but obeying other side conditions, e.g., concerning small bootstrap currents, good stability properties, reasonable aspect ratio, etc. This problem is addressed in the present work. Various stellarator vacuum field are given analytically for M 2, 3, 5, 10, 12 (M is the number of field period around the torus) where the PS-current density is reduced by more than a factor of ten to rather small values around 0.3 even at small i-values

  19. Imaging samples larger than the field of view: the SLS experience

    Science.gov (United States)

    Vogiatzis Oikonomidis, Ioannis; Lovric, Goran; Cremona, Tiziana P.; Arcadu, Filippo; Patera, Alessandra; Schittny, Johannes C.; Stampanoni, Marco

    2017-06-01

    Volumetric datasets with micrometer spatial and sub-second temporal resolutions are nowadays routinely acquired using synchrotron X-ray tomographic microscopy (SRXTM). Although SRXTM technology allows the examination of multiple samples with short scan times, many specimens are larger than the field-of-view (FOV) provided by the detector. The extension of the FOV in the direction perpendicular to the rotation axis remains non-trivial. We present a method that can efficiently increase the FOV merging volumetric datasets obtained by region-of-interest tomographies in different 3D positions of the sample with a minimal amount of artefacts and with the ability to handle large amounts of data. The method has been successfully applied for the three-dimensional imaging of a small number of mouse lung acini of intact animals, where pixel sizes down to the micrometer range and short exposure times are required.

  20. Preliminary design of a dedicated proton therapy linac

    International Nuclear Information System (INIS)

    Hamm, R.W.; Crandall, K.R.; Potter, J.M.

    1991-01-01

    The preliminary design has been completed for a low current, compact proton linac dedicated to cancer therapy. A 3 GHz side-coupled structure accelerates the beam from a 70 MeV drift tube linac using commercially available S-band rf power systems and accelerating cavities. This significantly reduces the linac cost and allows incremental energies up to 250 MeV. The short beam pulse width and high repetition rate make the linac similar to the high energy electron linacs now used for cancer therapy, yet produce a proton flux sufficient for treatment of large tumors. The high pulse repetition rate permits raster scanning, and the small output beam size and emittance result in a compact isocentric gantry design. Such a linac will reduce the facility and operating costs for a dedicated cancer therapy system

  1. Defining Constellation Suit Helmet Field of View Requirements Employing a Mission Segment Based Reduction Process

    Science.gov (United States)

    McFarland, Shane

    2009-01-01

    Field of view has always been a design feature paramount to helmets, and in particular space suits, where the helmet must provide an adequate field of view for a large range of activities, environments, and body positions. For Project Constellation, a different approach to helmet requirement maturation was utilized; one that was less a direct function of body position and suit pressure and more a function of the mission segment in which the field of view will be required. Through taxonimization of various parameters that affect suited field of view, as well as consideration for possible nominal and contingency operations during that mission segment, a reduction process was employed to condense the large number of possible outcomes to only six unique field of view angle requirements that still captured all necessary variables while sacrificing minimal fidelity.

  2. Hamamatsu C11204-01 calibration, test and design of a dedicated LabVIEW interface

    International Nuclear Information System (INIS)

    Nocerino, E.; Barbato, F.C.T.; De Asmundis, R.

    2017-01-01

    In the last 50 years solid state devices have been widely used as radiation detectors (photons, betas, fast electrons and heavy ions) thanks to the advantages they offer with respect to photomultiplier tubes technology. However, despite their benefits (low power consumption, small size, low costs), semiconductors are very sensitive to temperature variations. This means that for those experiments using solid state detectors without any thermal control, the correct operation of the detectors is affected by the environmental condition. To solve this problem Hamamatsu Photonics realized the C11204-01 device: a special voltage supply module for silicon photomultipliers which compensates the overvoltage at different temperatures. In the following work we present the results of the calibration of this device and a test we performed on a silicon photomultiplier, by means of a LabVIEW"T"M interface designed ad hoc for this purpose.

  3. Development of a circular shape Si-PM-based detector ring for breast-dedicated PET system

    Science.gov (United States)

    Nakanishi, Kouhei; Yamamoto, Seiichi; Watabe, Hiroshi; Abe, Shinji; Fujita, Naotoshi; Kato, Katsuhiko

    2018-02-01

    In clinical situations, various breast-dedicated positron emission tomography (PET) systems have been used. However, clinical breast-dedicated PET systems have polygonal detector ring. Polygonal detector ring sometimes causes image artifact, so complicated reconstruction algorithm is needed to reduce artifact. Consequently, we developed a circular detector ring for breast-dedicated PET to obtain images without artifact using a simple reconstruction algorithm. We used Lu1.9Gd0.1SiO5 (LGSO) scintillator block which was made of 1.5 x 1.9 x 15 mm pixels that were arranged in an 8 x 24 matrix. As photodetectors, we used silicon photomultiplier (Si-PM) arrays whose channel size was 3 x 3 mm. A detector unit was composed of four scintillator blocks, 16 Si-PM arrays and a light guide. The developed detector unit had angled configuration since the light guide was bending. A detector unit had three gaps with an angle of 5.625° between scintillator blocks. With these configurations, we could arrange 64 scintillator blocks in nearly circular shape (regular 64-sided polygon) using 16 detector units. The use of the smaller number of detector units could reduce the size of the front-end electronics circuits. The inner diameter of the developed detector ring was 260 mm. This size was similar to those of brain PET systems, so our breast-dedicated PET detector ring can measure not only breast but also brain. Measured radial, tangential and axial spatial resolution of the detector ring reconstructed by the filtered back-projection (FBP) algorithm were 2.1 mm FWHM, 2.0 mm FWHM and 1.7 mm FWHM at center of field of view (FOV), respectively. The sensitivity was 2.0% at center of the axial FOV. With the developed detector ring, we could obtain high resolution image of the breast phantom and the brain phantom. We conclude that our developed Si-PM-based detector ring is promising for a high resolution breast-dedicated PET system that can also be used for brain PET system.

  4. Mimicking honeybee eyes with a 2800 field of view catadioptric imaging system

    International Nuclear Information System (INIS)

    Stuerzl, W; Boeddeker, N; Dittmar, L; Egelhaaf, M

    2010-01-01

    We present a small single camera imaging system that provides a continuous 280 0 field of view (FOV) inspired by the large FOV of insect eyes. This is achieved by combining a curved reflective surface that is machined into acrylic glass with lenses covering the frontal field that otherwise would have been obstructed by the mirror. Based on the work of Seidl (1982 PhD Thesis Technische Hochschule Darmstadt), we describe an extension of the 'bee eye optics simulation' (BEOS) model by Giger (1996 PhD Thesis Australian National University) to the full FOV which enables us to remap camera images according to the spatial resolution of honeybee eyes. This model is also useful for simulating the visual input of a bee-like agent in a virtual environment. The imaging system in combination with our bee eye model can serve as a tool for assessing the visual world from a bee's perspective which is particularly helpful for experimental setups. It is also well suited for mobile robots, in particular on flying vehicles that need light-weight sensors.

  5. High sensitivity of quick view capsule endoscopy for detection of small bowel Crohn's disease

    DEFF Research Database (Denmark)

    Halling, Morten Lee; Nathan, Torben; Kjeldsen, Jens

    2014-01-01

    Capsule endoscopy (CE) has a high sensitivity for diagnosing small bowel Crohn's disease, but video analysis is time consuming. The quick view (qv) function is an effective tool to reduce time consumption. The aim of this study was to determine the rate of missed small bowel ulcerations with qv-C...

  6. View of the Axial Field Spectrometer (R807)

    CERN Multimedia

    1980-01-01

    In this view of the Axial Field Spectrometer at I8, the vertical uranium/scintillator hadron calorimeter (just left of centre) is retracted to give access to the cylindrical central drift chamber. The yellow iron structure served as a filter to identify muons, with MWPCs and the array of Cherenkov counters to the right.

  7. Initial clinical experience with dedicated ultra fast solid state cardiac gamma camera

    International Nuclear Information System (INIS)

    Aland, Nusrat; Lele, V.

    2010-01-01

    detector reducing camera related motion artifacts. Diagnostic performance was comparable to that of standard dual detector gamma camera images. Mid septum invariably showed perfusion defects in QPS protocol, this probably was due to lack of normal database for solid state detector. Lung activity could not be visualized due to small field of view. Extra cardiac activity could be assessed. CONCLUSION: We preferred solid state cardiac gamma camera over conventional dual detector gamma camera for myocardial perfusion imaging. Advantages of solid state gamma camera over standard dual head gamma camera: 1. Faster acquisition time 2. Increased patient comfort 3. Less radiation dose to the patient 4. Brighter images 5. No motion artifact 6. Better right ventricular imaging Disadvantages 1. Extra cardiac activity cannot be assessed 2. Lung activity not seen due to small field of view 3. Invariably septal perfusion defects noted

  8. Effect of field-of-view on the Coriolis illusion

    NARCIS (Netherlands)

    Groen, E.L.; Muis, H.; Kooi, F.L.

    2008-01-01

    Tilting the head during rotation about an Earth-vertical axis produces cross-coupled stimulation of the semicircular canals. Without visual feedback on the actual self-motion, this leads to the so-called Coriolis illusion. We investigated the effect of the field-of-view (FOV) on the magnitude and

  9. Minimization of small bowel volume within treatment fields using customized small bowel displacement system (SBDS)

    International Nuclear Information System (INIS)

    Lim, D. H.; Huh, S. J.; Ahn, Y. C.; Kim, D. Y.; Wu, H. G.; Kim, M. K.; Choi, D. R.; Shin, K. H.

    1997-01-01

    Authors designed a customized Small Bowel Displacement System(SBDS) to displace the small bowel from the pelvic radiation fields and minimize treatment-related bowel morbidities. From August 1995 to May 1996, 55 consecutive patients who received pelvic radiation therapy with the SBDS were included in this study. The SBDS consists of a customized styrofoam compression device which can displace the small bowel from the radiation fields and an individualized immobilization abdominal board for easy daily setup in prone position. After opacifying the small bowel with Barium, the patients were laid prone and posterior-anterior (PA) and lateral (LAT) simulation films were taken with and without the SBDS. The areas of the small bowel included in the radiation fields with and without the SBDS were compared. Using the SBDS, the mean small bowel area was reduced by 59% on PA and 51% on LAT films (P=0.0001). In six patients (6/55, 11%), it was possible that no small bowel was included within the treatment fields. The mean upward displacement of the most caudal small bowel was 4.8 cm using the SBDS. Only 15% (8/55) of patients treated with the SBDS manifested diarrhea requiring medication. The SBDS is a novel method that can be used to displace the small bowel away from the treatment portal effectively and reduce the radiation therapy morbidities. Compliance with setup is excellent when the SBDS is used. (author)

  10. Environmental Sciences Laboratory dedication, February 26-27, 1979

    International Nuclear Information System (INIS)

    Auerbach, S.I.; Millemann, N.T.

    1980-09-01

    The dedication of the new Environmental Sciences Laboratory coincided with the 25th year of the establishment of the science of ecology at Oak Ridge National Laboratory. That quarter century witnessed the evolution of ecology from an obscure, backwater discipline of biology to a broadly used, everyday household word. The transition reflected broad and basic changes in our social and cultural view of the world. This was brought about as a result of the awareness developed in our society of the importance of the environment, coupled with efforts of ecologists and other environmental scientists who identified, clarified, and formulated the issues and challenges of environmental protection for both the lay public and the scientific community. In many respects, the activities in ecology at ORNL were a microcosm of the broader social scene; the particular problems of the environment associated with atomic energy needed to be defined in scientific terms and articulated in both the specific and general sense for a larger audience which was unfamiliar with the field and somewhat alien to its concepts and philosophy. The success of this effort is reflected in the existence of the new Environmental Sciences Laboratory. This dedication volume brings together the thoughts and reflections of many of these scientists whose efforts contributed in a unique and individualistic fashion not only to ORNL but also to the national identification of ecology and its importance to the achievement of our national goals. Their remarks and presentations are not only a pleasant and personally gratifying recapitulation of the past and of ORNL's contributions to ecology but also portend some of the challenges to ecology in the future

  11. Environmental Sciences Laboratory dedication, February 26-27, 1979

    Energy Technology Data Exchange (ETDEWEB)

    Auerbach, S.I.; Millemann, N.T. (eds.)

    1980-09-01

    The dedication of the new Environmental Sciences Laboratory coincided with the 25th year of the establishment of the science of ecology at Oak Ridge National Laboratory. That quarter century witnessed the evolution of ecology from an obscure, backwater discipline of biology to a broadly used, everyday household word. The transition reflected broad and basic changes in our social and cultural view of the world. This was brought about as a result of the awareness developed in our society of the importance of the environment, coupled with efforts of ecologists and other environmental scientists who identified, clarified, and formulated the issues and challenges of environmental protection for both the lay public and the scientific community. In many respects, the activities in ecology at ORNL were a microcosm of the broader social scene; the particular problems of the environment associated with atomic energy needed to be defined in scientific terms and articulated in both the specific and general sense for a larger audience which was unfamiliar with the field and somewhat alien to its concepts and philosophy. The success of this effort is reflected in the existence of the new Environmental Sciences Laboratory. This dedication volume brings together the thoughts and reflections of many of these scientists whose efforts contributed in a unique and individualistic fashion not only to ORNL but also to the national identification of ecology and its importance to the achievement of our national goals. Their remarks and presentations are not only a pleasant and personally gratifying recapitulation of the past and of ORNL's contributions to ecology but also portend some of the challenges to ecology in the future.

  12. The effect of metal artifacts on the identification of vertical root fractures using different fields of view in cone-beam computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Moudi, Ehsan; Haghanifar, Sina; Madani, Zahrasadat; Bijani, Ali; Nabavi, Zeynab Sadat [Babol University of Medical Science, Babol (Iran, Islamic Republic of)

    2015-09-15

    The aim of this study was to investigate the effects of metal artifacts on the accurate diagnosis of root fractures using cone-beam computed tomography (CBCT) images with large and small/limited fields of view (FOVs). Forty extracted molar and premolar teeth were collected. Access canals were made in all teeth using a rotary system. In half of the teeth, fractures were created by the application of mild pressure with a hammer. The teeth were then randomly put into a wax rim on an acryl base designed in the shape of a mandible. CBCT scans were obtained using a Newtom 5G system with FOVs of 18 cm×16 cm and 6 cm×6 cm. A metal pin was then placed into each tooth, and CBCT imaging was again performed using the same fields of view. All scans were evaluated by two oral and maxillofacial radiologists. The specificity, sensitivity, positive predictive value, negative predictive value, and likelihood ratios (positive and negative) were calculated. The maximum levels of sensitivity and specificity (100% and 100%, respectively) were observed in small volume CBCT scans of teeth without pins. The highest negative predictive value was found in the small-volume group without pins, whereas the positive predictive value was 100% in all groups except the large-volume group with pins.

  13. Near-Field Sound Localization Based on the Small Profile Monaural Structure

    Directory of Open Access Journals (Sweden)

    Youngwoong Kim

    2015-11-01

    Full Text Available The acoustic wave around a sound source in the near-field area presents unconventional properties in the temporal, spectral, and spatial domains due to the propagation mechanism. This paper investigates a near-field sound localizer in a small profile structure with a single microphone. The asymmetric structure around the microphone provides a distinctive spectral variation that can be recognized by the dedicated algorithm for directional localization. The physical structure consists of ten pipes of different lengths in a vertical fashion and rectangular wings positioned between the pipes in radial directions. The sound from an individual direction travels through the nearest open pipe, which generates the particular fundamental frequency according to the acoustic resonance. The Cepstral parameter is modified to evaluate the fundamental frequency. Once the system estimates the fundamental frequency of the received signal, the length of arrival and angle of arrival (AoA are derived by the designed model. From an azimuthal distance of 3–15 cm from the outer body of the pipes, the extensive acoustic experiments with a 3D-printed structure show that the direct and side directions deliver average hit rates of 89% and 73%, respectively. The closer positions to the system demonstrate higher accuracy, and the overall hit rate performance is 78% up to 15 cm away from the structure body.

  14. Wide field-of-view dual-band multispectral muzzle flash detection

    Science.gov (United States)

    Montoya, J.; Melchor, J.; Spiliotis, P.; Taplin, L.

    2013-06-01

    Sensor technologies are undergoing revolutionary advances, as seen in the rapid growth of multispectral methodologies. Increases in spatial, spectral, and temporal resolution, and in breadth of spectral coverage, render feasible sensors that function with unprecedented performance. A system was developed that addresses many of the key hardware requirements for a practical dual-band multispectral acquisition system, including wide field of view and spectral/temporal shift between dual bands. The system was designed using a novel dichroic beam splitter and dual band-pass filter configuration that creates two side-by-side images of a scene on a single sensor. A high-speed CMOS sensor was used to simultaneously capture data from the entire scene in both spectral bands using a short focal-length lens that provided a wide field-of-view. The beam-splitter components were arranged such that the two images were maintained in optical alignment and real-time intra-band processing could be carried out using only simple arithmetic on the image halves. An experiment related to limitations of the system to address multispectral detection requirements was performed. This characterized the system's low spectral variation across its wide field of view. This paper provides lessons learned on the general limitation of key hardware components required for multispectral muzzle flash detection, using the system as a hardware example combined with simulated multispectral muzzle flash and background signatures.

  15. Small field electron beam dosimetry using MOSFET detector.

    Science.gov (United States)

    Amin, Md Nurul; Heaton, Robert; Norrlinger, Bern; Islam, Mohammad K

    2010-10-04

    The dosimetry of very small electron fields can be challenging due to relative shifts in percent depth-dose curves, including the location of dmax, and lack of lateral electronic equilibrium in an ion chamber when placed in the beam. Conventionally a small parallel plate chamber or film is utilized to perform small field electron beam dosimetry. Since modern radiotherapy departments are becoming filmless in favor of electronic imaging, an alternate and readily available clinical dosimeter needs to be explored. We have studied the performance of MOSFET as a relative dosimeter in small field electron beams. The reproducibility, linearity and sensitivity of a high-sensitivity microMOSFET were investigated for clinical electron beams. In addition, the percent depth doses, output factors and profiles have been measured in a water tank with MOSFET and compared with those measured by an ion chamber for a range of field sizes from 1 cm diameter to 10 cm × 10 cm for 6, 12, 16 and 20 MeV beams. Similar comparative measurements were also per-formed with MOSFET and films in solid water phantom. The MOSFET sensitivity was found to be practically constant over the range of field sizes investigated. The dose response was found to be linear and reproducible (within ± 1% for 100 cGy). An excellent agreement was observed among the central axis depth dose curves measured using MOSFET, film and ion chamber. The output factors measured with MOSFET for small fields agreed to within 3% with those measured by film dosimetry. Overall results indicate that MOSFET can be utilized to perform dosimetry for small field electron beam.

  16. Context Counts: Viewing Small School Leadership from the Inside out

    Science.gov (United States)

    Clarke, Simon; Wildy, Helen

    2004-01-01

    This paper proceeds from the basis that leadership can only be understood in context and by viewing it from the inside. In particular, it argues that the contextual complexity of small school leadership warrants attention from researchers, policy makers and system administrators and describes the nature of this complexity as depicted in the…

  17. Geomagnetic reversals, polar ice and cosmic spherules: some recent measurements with a small dedicated accelerator mass-spectrometry facility

    International Nuclear Information System (INIS)

    Raisbeck, G.M.; Yiou, F.

    1987-01-01

    We have developed techniques for measuring the cosmogenic isotopes 10 Be (half-life 1.5 Ma) and 26 Al (716 ka) by using a small (ca. 2.2 MV) dedicated accelerator mass spectrometer facility. Three recent applications of such measurements are as follows. 1. 10 Be has been measured in marine-sediment cores at levels corresponding to three recent geomagnetic reversals. We observe an increase in 10 Be production at each of these times. The results give information on the form and length of the geomagnetic intensity changes during a reversal, and the level at which magnetic remanence is acquired in the sediments. 2. 10 Be has been measured over a 2083 m ice core, corresponding to the last climatic cycle, recovered from Vostok, Antarctica. The results suggest that the precipitation rate during the last Ice Age was about half of its present rate. There are also some indications of fairly rapid 10 Be production changes. 3. 10 Be and 26 Al have been measured in 'cosmic spherules' (small round objects, ca. 500 μm diameter) recovered in deep-sea sediments and in melt lakes on Greenland ice. The results confirm an extraterrestrial origin for such objects, as well as indicating that the parent bodies of most of them were irradiated in space as small (less than 1 cm) objects. These spherules thus very probably represent cometary debris. (author)

  18. Face inversion and acquired prosopagnosia reduce the size of the perceptual field of view.

    Science.gov (United States)

    Van Belle, Goedele; Lefèvre, Philippe; Rossion, Bruno

    2015-03-01

    Using a gaze-contingent morphing approach, we asked human observers to choose one of two faces that best matched the identity of a target face: one face corresponded to the reference face's fixated part only (e.g., one eye), the other corresponded to the unfixated area of the reference face. The face corresponding to the fixated part was selected significantly more frequently in the inverted than in the upright orientation. This observation provides evidence that face inversion reduces an observer's perceptual field of view, even when both upright and inverted faces are displayed at full view and there is no performance difference between these conditions. It rules out an account of the drop of performance for inverted faces--one of the most robust effects in experimental psychology--in terms of a mere difference in local processing efficiency. A brain-damaged patient with pure prosopagnosia, viewing only upright faces, systematically selected the face corresponding to the fixated part, as if her perceptual field was reduced relative to normal observers. Altogether, these observations indicate that the absence of visual knowledge reduces the perceptual field of view, supporting an indirect view of visual perception. Copyright © 2014 Elsevier B.V. All rights reserved.

  19. Small fields measurements with radiochromic films.

    Science.gov (United States)

    Gonzalez-Lopez, Antonio; Vera-Sanchez, Juan-Antonio; Lago-Martin, Jose-Domingo

    2015-01-01

    The small fields in radiotherapy are widely used due to the development of techniques such as intensity-modulated radiotherapy and stereotactic radio surgery. The measurement of the dose distributions for small fields is a challenge. A perfect dosimeter should be independent of the radiation energy and the dose rate and should have a negligible volume effect. The radiochromic (RC) film characteristics fit well to these requirements. However, the response of RC films and their digitizing processes present a significant spatial inhomogeneity problem. The present work uses a method for two-dimensional (2D) measurement with RC films based on the reduction of the spatial inhomogeneity of both the film and the film digitizing process. By means of registering and averaging several measurements of the same field, the inhomogeneities are mostly canceled. Measurements of output factors (OFs), dose profiles (in-plane and cross-plane), and 2D dose distributions are presented. The field sizes investigated are 0.5 × 0.5 cm(2), 0.7 × 0.7 cm(2), 1 × 1 cm(2), 2 × 2 cm(2), 3 × 3 cm(2), 6 × 6 cm(2), and 10 × 10 cm(2) for 6 and 15 MV photon beams. The OFs measured with the RC film are compared with the measurements carried out with a PinPoint ionization chamber (IC) and a Semiflex IC, while the measured transversal dose profiles were compared with Monte Carlo simulations. The results obtained for the OFs measurements show a good agreement with the values obtained from RC films and the PinPoint and Semiflex chambers when the field size is greater or equal than 2 × 2 cm(2). These agreements give confidence on the accuracy of the method as well as on the results obtained for smaller fields. Also, good agreement was found between the measured profiles and the Monte Carlo calculated profiles for the field size of 1 × 1 cm(2). We expect, therefore, that the presented method can be used to perform accurate measurements of small fields.

  20. Holographic elements and curved slit used to enlarge field of view in rocket detection system

    Science.gov (United States)

    Breton, Mélanie; Fortin, Jean; Lessard, Roger A.; Châteauneuf, Marc

    2006-09-01

    Rocket detection over a wide field of view is an important issue in the protection of light armored vehicle. Traditionally, the detection occurs in UV band, but recent studies have shown the existence of significant emission peaks in the visible and near infrared at rocket launch time. The use of the visible region is interesting in order to reduce the weight and cost of systems. Current methods to detect those specific peaks involve use of interferometric filters. However, they fail to combine wide angle with wavelength selectivity. A linear array of volume holographic elements combined with a curved exit slit is proposed for the development of a wide field of view sensor for the detection of solid propellant motor launch flash. The sensor is envisaged to trigger an active protection system. On the basis of geometric theory, a system has been designed. It consists of a collector, a linear array of holographic elements, a curved slit and a detector. The collector is an off-axis parabolic mirror. Holographic elements are recorded subdividing a hologram film in regions, each individually exposed with a different incidence angle. All regions have a common diffraction angle. The incident angle determines the instantaneous field of view of the elements. The volume hologram performs the function of separating and focusing the diffracted beam on an image plane to achieve wavelength filtering. Conical diffraction property is used to enlarge the field of view in elevation. A curved slit was designed to correspond to oblique incidence of the holographic linear array. It is situated at the image plane and filters the diffracted spectrum toward the sensor. The field of view of the design was calculated to be 34 degrees. This was validated by a prototype tested during a field trial. Results are presented and analyzed. The system succeeded in detecting the rocket launch flash at desired fields of view.

  1. Optical system design of CCD star sensor with large aperture and wide field of view

    Science.gov (United States)

    Wang, Chao; Jiang, Lun; Li, Ying-chao; Liu, Zhuang

    2017-10-01

    The star sensor is one of the sensors which are used to determine the spatial attitude of the space vehicle. An optical system of star sensor with large aperture and wide field of view was designed in this paper. The effective focal length of the optics was 16mm, and the F-number is 1.2, the field of view of the optical system is 20°.The working spectrum is 500 to 800 nanometer. The lens system selects a similar complicated Petzval structure and special glass-couple, and get a high imaging quality in the whole spectrum range. For each field-of-view point, the values of the modulation transfer function at 50 cycles/mm is higher than 0.3. On the detecting plane, the encircled energy in a circle of 14μm diameter could be up to 80% of the total energy. In the whole range of the field of view, the dispersion spot diameter in the imaging plane is no larger than 13μm. The full field distortion was less than 0.1%, which was helpful to obtain the accurate location of the reference star through the picture gotten by the star sensor. The lateral chromatic aberration is less than 2μm in the whole spectrum range.

  2. MMS Multipoint Electric Field Observations of Small-Scale Magnetic Holes

    Science.gov (United States)

    Goodrich, Katherine A.; Ergun, Robert E.; Wilder, Frederick; Burch, James; Torbert, Roy; Khotyaintsev, Yuri; Lindqvist, Per-Arne; Russell, Christopher; Strangeway, Robert; Magnus, Werner

    2016-01-01

    Small-scale magnetic holes (MHs), local depletions in magnetic field strength, have been observed multiple times in the Earths magnetosphere in the bursty bulk flow (BBF) braking region. This particular subset of MHs has observed scale sizes perpendicular to the background magnetic field (B) less than the ambient ion Larmor radius (p(sib i)). Previous observations by Time History of Events and Macroscale Interactions during Substorms (THEMIS) indicate that this subset of MHs can be supported by a current driven by the E x B drift of electrons. Ions do not participate in the E x B drift due to the small-scale size of the electric field. While in the BBF braking region, during its commissioning phase, the Magnetospheric Multiscale (MMS) spacecraft observed a small-scale MH. The electric field observations taken during this event suggest the presence of electron currents perpendicular to the magnetic field. These observations also suggest that these currents can evolve to smaller spatial scales.

  3. Life Cycle Analysis of Dedicated Nano-Launch Technologies

    Science.gov (United States)

    Zapata, Edgar; McCleskey, Carey (Editor); Martin, John; Lepsch, Roger; Ternani, Tosoc

    2014-01-01

    Recent technology advancements have enabled the development of small cheap satellites that can perform useful functions in the space environment. Currently, the only low cost option for getting these payloads into orbit is through ride share programs - small satellites awaiting the launch of a larger satellite, and then riding along on the same launcher. As a result, these small satellite customers await primary payload launches and a backlog exists. An alternative option would be dedicated nano-launch systems built and operated to provide more flexible launch services, higher availability, and affordable prices. The potential customer base that would drive requirements or support a business case includes commercial, academia, civil government and defense. Further, NASA technology investments could enable these alternative game changing options. With this context, in 2013 the Game Changing Development (GCD) program funded a NASA team to investigate the feasibility of dedicated nano-satellite launch systems with a recurring cost of less than $2 million per launch for a 5 kg payload to low Earth orbit. The team products would include potential concepts, technologies and factors for enabling the ambitious cost goal, exploring the nature of the goal itself, and informing the GCD program technology investment decision making process. This paper provides an overview of the life cycle analysis effort that was conducted in 2013 by an inter-center NASA team. This effort included the development of reference nano-launch system concepts, developing analysis processes and models, establishing a basis for cost estimates (development, manufacturing and launch) suitable to the scale of the systems, and especially, understanding the relationship of potential game changing technologies to life cycle costs, as well as other factors, such as flights per year.

  4. Dynamic contrast-enhanced imaging of the wrist in rheumatoid arthritis: dedicated low-field (0.25-T) versus high-field (3.0-T) MRI

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Ryan K.L.; Griffith, James F.; Wang, D.F.; Yeung, David K.W. [The Chinese University of Hong Kong, Department of Imaging and Interventional Radiology, Prince Of Wales Hospital, Hong Kong, SAR (China); Shi, L. [The Chinese University of Hong Kong, Department of Medicine and Therapeutics, Division of Neurology, Hong Kong, SAR (China); Li, Edmund K.; Tam, L.S. [The Chinese University of Hong Kong, Department of Medicine, Division of Rheumatology, Prince Of Wales Hospital, Hong Kong, SAR (China)

    2015-08-15

    To compare the assessment of wrist synovitis severity, synovial volume and synovial perfusion parameters on a dedicated low-field (0.25-T) to that of a high-field (3-T) whole-body MR system in patients with rheumatoid arthritis (RA). Twenty-one patients (mean age 50.0 ± 9.8 years) with active RA were recruited prospectively. Dynamic contrast-enhanced MRI examination of the most severely affected wrist was performed at both 0.25 T and 3 T. Three MRI-derived parameters, synovitis severity (RAMRIS grade), synovial volume (ml{sup 3}) and synovial perfusion indices (maximum enhancement and enhancement slope), were compared. Comparing 0.25- and 3-T MRI, there was excellent agreement for semiquantitative assessment (r: 0.80, p < 0.00001) of synovitis (RAMRIS) as well as quantitative assessment (r: 0.94, p < 0.00001) of synovial volume. Good agreement for synovial Emax (r: 0.6, p = 0.002) and fair agreement (r: 0.5, p = 0.02) for synovial Eslope was found. Imaging of the RA wrist at 0.25 T yields excellent correlation with 3 T with regard to the synovitis activity score (RAMRIS) and synovial volume measurement. Fair to good correlation between low- (0.25-T) and high-field (3-T) MR systems was found for perfusion parameters, being better for Emax than for Eslope. (orig.)

  5. Mimicking honeybee eyes with a 280{sup 0} field of view catadioptric imaging system

    Energy Technology Data Exchange (ETDEWEB)

    Stuerzl, W; Boeddeker, N; Dittmar, L; Egelhaaf, M, E-mail: wolfgang.stuerzl@uni-bielefeld.d [Department of Neurobiology and Center of Excellence ' Cognitive Interaction Technology' , Bielefeld University (Germany)

    2010-09-15

    We present a small single camera imaging system that provides a continuous 280{sup 0} field of view (FOV) inspired by the large FOV of insect eyes. This is achieved by combining a curved reflective surface that is machined into acrylic glass with lenses covering the frontal field that otherwise would have been obstructed by the mirror. Based on the work of Seidl (1982 PhD Thesis Technische Hochschule Darmstadt), we describe an extension of the 'bee eye optics simulation' (BEOS) model by Giger (1996 PhD Thesis Australian National University) to the full FOV which enables us to remap camera images according to the spatial resolution of honeybee eyes. This model is also useful for simulating the visual input of a bee-like agent in a virtual environment. The imaging system in combination with our bee eye model can serve as a tool for assessing the visual world from a bee's perspective which is particularly helpful for experimental setups. It is also well suited for mobile robots, in particular on flying vehicles that need light-weight sensors.

  6. Laboratory and Field Investigations of Small Crater Repair Technologies

    National Research Council Canada - National Science Library

    Priddy, Lucy P; Tingle, Jeb S; McCaffrey, Timothy J; Rollings, Ray S

    2007-01-01

    .... This airfield damage repair (ADR) investigation consisted of laboratory testing of selected crater fill and capping materials, as well as full-scale field testing of small crater repairs to evaluate field mixing methods, installation...

  7. Hemispherical-field-of-view, nonimaging narrow-band spectral filter

    Science.gov (United States)

    Miles, R. B.; Webb, S. G.; Griffith, E. L.

    1981-01-01

    Two compound parabolic concentrators are used to create a 180-deg-field-of-view spectral filter. The collection optics are reflective and are designed to collimate the light through a multilayer interference filter and then to refocus it onto an optical detector. Assuming unit reflectance and no loss through the optical filter, this device operates at the thermodynamic collection limit.

  8. [System design of small intellectualized ultrasound hyperthermia instrument in the LabVIEW environment].

    Science.gov (United States)

    Jiang, Feng; Bai, Jingfeng; Chen, Yazhu

    2005-08-01

    Small-scale intellectualized medical instrument has attracted great attention in the field of biomedical engineering, and LabVIEW (Laboratory Virtual Instrument Engineering Workbench) provides a convenient environment for this application due to its inherent advantages. The principle and system structure of the hyperthermia instrument are presented. Type T thermocouples are employed as thermotransducers, whose amplifier consists of two stages, providing built-in ice point compensation and thus improving work stability over temperature. Control signals produced by specially designed circuit drive the programmable counter/timer 8254 chip to generate PWM (Pulse width modulation) wave, which is used as ultrasound radiation energy control signal. Subroutine design topics such as inner-tissue real time feedback temperature control algorithm, water temperature control in the ultrasound applicator are also described. In the cancer tissue temperature control subroutine, the authors exert new improvments to PID (Proportional Integral Differential) algorithm according to the specific demands of the system and achieve strict temperature control to the target tissue region. The system design and PID algorithm improvement have experimentally proved to be reliable and excellent, meeting the requirements of the hyperthermia system.

  9. TH-EF-204-05: Application of Small-Field Treatment: The Promises and Pitfalls of SBRT

    International Nuclear Information System (INIS)

    Ford, E.

    2016-01-01

    Joanna E. Cygler, Jan Seuntjens, J. Daniel Bourland, M. Saiful Huq, Josep Puxeu Vaque, Daniel Zucca Aparicio, Tatiana Krylova, Yuri Kirpichev, Eric Ford, Caridad Borras Stereotactic Radiation Therapy (SRT) utilizes small static and dynamic (IMRT) fields, to successfully treat malignant and benign diseases using techniques such as Stereotactic Radiosurgery (SRS) and Stereotactic Body Radiation Therapy (SBRT). SRT is characterized by sharp dose gradients for individual fields and their resultant dose distributions. For appropriate targets, small field radiotherapy offers improved treatment quality by allowing better sparing of organs at risk while delivering the prescribed target dose. Specialized small field treatment delivery systems, such as robotic-controlled linear accelerators, gamma radiosurgery units, and dynamic arc linear accelerators may utilize rigid fixation, image guidance, and tumor tracking, to insure precise dose delivery to static or moving targets. However, in addition to great advantages, small field delivery techniques present special technical challenges for dose calibration due to unique geometries and small field sizes not covered by existing reference dosimetry protocols such as AAPM TG-51 or IAEA TRS 398. In recent years extensive research has been performed to understand small field dosimetry and measurement instrumentation. AAPM, IAEA and ICRU task groups are expected to provide soon recommendations on the dosimetry of small radiation fields. In this symposium we will: 1] discuss the physics, instrumentation, methodologies and challenges for small field radiation dose measurements; 2] review IAEA and ICRU recommendations on prescribing, recording and reporting of small field radiation therapy; 3] discuss selected clinical applications and technical aspects for specialized image-guided, small field, linear accelerator based treatment techniques such as IMRT and SBRT. Learning Objectives: To learn the physics of small fields in contrast to

  10. TH-EF-204-05: Application of Small-Field Treatment: The Promises and Pitfalls of SBRT

    Energy Technology Data Exchange (ETDEWEB)

    Ford, E. [University of Washington (United States)

    2016-06-15

    Joanna E. Cygler, Jan Seuntjens, J. Daniel Bourland, M. Saiful Huq, Josep Puxeu Vaque, Daniel Zucca Aparicio, Tatiana Krylova, Yuri Kirpichev, Eric Ford, Caridad Borras Stereotactic Radiation Therapy (SRT) utilizes small static and dynamic (IMRT) fields, to successfully treat malignant and benign diseases using techniques such as Stereotactic Radiosurgery (SRS) and Stereotactic Body Radiation Therapy (SBRT). SRT is characterized by sharp dose gradients for individual fields and their resultant dose distributions. For appropriate targets, small field radiotherapy offers improved treatment quality by allowing better sparing of organs at risk while delivering the prescribed target dose. Specialized small field treatment delivery systems, such as robotic-controlled linear accelerators, gamma radiosurgery units, and dynamic arc linear accelerators may utilize rigid fixation, image guidance, and tumor tracking, to insure precise dose delivery to static or moving targets. However, in addition to great advantages, small field delivery techniques present special technical challenges for dose calibration due to unique geometries and small field sizes not covered by existing reference dosimetry protocols such as AAPM TG-51 or IAEA TRS 398. In recent years extensive research has been performed to understand small field dosimetry and measurement instrumentation. AAPM, IAEA and ICRU task groups are expected to provide soon recommendations on the dosimetry of small radiation fields. In this symposium we will: 1] discuss the physics, instrumentation, methodologies and challenges for small field radiation dose measurements; 2] review IAEA and ICRU recommendations on prescribing, recording and reporting of small field radiation therapy; 3] discuss selected clinical applications and technical aspects for specialized image-guided, small field, linear accelerator based treatment techniques such as IMRT and SBRT. Learning Objectives: To learn the physics of small fields in contrast to

  11. Synchronized High-Speed Vision Sensor Network for Expansion of Field of View

    Directory of Open Access Journals (Sweden)

    Akihito Noda

    2018-04-01

    Full Text Available We propose a 500-frames-per-second high-speed vision (HSV sensor network that acquires frames at a timing that is precisely synchronized across the network. Multiple vision sensor nodes, individually comprising a camera and a PC, are connected via Ethernet for data transmission and for clock synchronization. A network of synchronized HSV sensors provides a significantly expanded field-of-view compared with that of each individual HSV sensor. In the proposed system, the shutter of each camera is controlled based on the clock of the PC locally provided inside the node, and the shutters are globally synchronized using the Precision Time Protocol (PTP over the network. A theoretical analysis and experiment results indicate that the shutter trigger skew among the nodes is a few tens of microseconds at most, which is significantly smaller than the frame interval of 1000-fps-class high-speed cameras. Experimental results obtained with the proposed system comprising four nodes demonstrated the ability to capture the propagation of a small displacement along a large-scale structure.

  12. Personalized estimates of radiation dose from dedicated breast CT in a diagnostic population and comparison with diagnostic mammography

    International Nuclear Information System (INIS)

    Vedantham, Srinivasan; Shi, Linxi; Karellas, Andrew; O'Connell, Avice M; Conover, David L

    2013-01-01

    This study retrospectively analyzed the mean glandular dose (MGD) to 133 breasts from 132 subjects, all women, who participated in a clinical trial evaluating dedicated breast CT in a diagnostic population. The clinical trial was conducted in adherence to a protocol approved by institutional review boards and the study participants provided written informed consent. Individual estimates of MGD to each breast from dedicated breast CT was obtained by combining x-ray beam characteristics with estimates of breast dimensions and fibroglandular fraction from volumetric breast CT images, and using normalized glandular dose coefficients. For each study participant and for the breast corresponding to that imaged with breast CT, an estimate of the MGD from diagnostic mammography (including supplemental views) was obtained from the DICOM image headers for comparison. This estimate uses normalized glandular dose coefficients corresponding to a breast with 50% fibroglandular weight fraction. The median fibroglandular weight fraction for the study cohort determined from volumetric breast CT images was 15%. Hence, the MGD from diagnostic mammography was corrected to be representative of the study cohort. Individualized estimates of MGD from breast CT ranged from 5.7 to 27.8 mGy. Corresponding to the breasts imaged with breast CT, the MGD from diagnostic mammography ranged from 2.6 to 31.6 mGy. The mean (± inter-breast SD) and the median MGD (mGy) from dedicated breast CT exam were 13.9 ± 4.6 and 12.6, respectively. For the corresponding breasts, the mean (± inter-breast SD) and the median MGD (mGy) from diagnostic mammography were 12.4 ± 6.3 and 11.1, respectively. Statistical analysis indicated that at the 0.05 level, the distributions of MGD from dedicated breast CT and diagnostic mammography were significantly different (Wilcoxon signed ranks test, p = 0.007). While the interquartile range and the range (maximum–minimum) of MGD from dedicated breast CT was lower than

  13. Design and field tests of a modified small mammallivetrap

    African Journals Online (AJOL)

    -vinyl-chloride) and metal small mammal live-trap has been developed and subjected to field tests. The PVC traps captured greater numbers of very small rodents and shrews but fewer large rodents than did hardboard ones. s. Afr. J. Zool.

  14. [A focused sound field measurement system by LabVIEW].

    Science.gov (United States)

    Jiang, Zhan; Bai, Jingfeng; Yu, Ying

    2014-05-01

    In this paper, according to the requirement of the focused sound field measurement, a focused sound field measurement system was established based on the LabVIEW virtual instrument platform. The system can automatically search the focus position of the sound field, and adjust the scanning path according to the size of the focal region. Three-dimensional sound field scanning time reduced from 888 hours in uniform step to 9.25 hours in variable step. The efficiency of the focused sound field measurement was improved. There is a certain deviation between measurement results and theoretical calculation results. Focal plane--6 dB width difference rate was 3.691%, the beam axis--6 dB length differences rate was 12.937%.

  15. Immersive viewing engine

    Science.gov (United States)

    Schonlau, William J.

    2006-05-01

    An immersive viewing engine providing basic telepresence functionality for a variety of application types is presented. Augmented reality, teleoperation and virtual reality applications all benefit from the use of head mounted display devices that present imagery appropriate to the user's head orientation at full frame rates. Our primary application is the viewing of remote environments, as with a camera equipped teleoperated vehicle. The conventional approach where imagery from a narrow field camera onboard the vehicle is presented to the user on a small rectangular screen is contrasted with an immersive viewing system where a cylindrical or spherical format image is received from a panoramic camera on the vehicle, resampled in response to sensed user head orientation and presented via wide field eyewear display, approaching 180 degrees of horizontal field. Of primary interest is the user's enhanced ability to perceive and understand image content, even when image resolution parameters are poor, due to the innate visual integration and 3-D model generation capabilities of the human visual system. A mathematical model for tracking user head position and resampling the panoramic image to attain distortion free viewing of the region appropriate to the user's current head pose is presented and consideration is given to providing the user with stereo viewing generated from depth map information derived using stereo from motion algorithms.

  16. Dedicated extremity MR imaging of the foot and ankle

    International Nuclear Information System (INIS)

    Hottya, G.A.; Peterfy, C.G.; Uffmann, M.; Haeckl, F.O.; LeHir, P.; Redei, J.; Gindele, A.U.; Dion, E.; Genant, H.K.

    2000-01-01

    The purpose of this review is to provide illustrative examples of diseases of the foot and ankle when imaged with a low-field MR imaging system. A retrospective review of 268 foot and ankle examinations, performed in our institution within the past 3 years with a 0.2-T (Artoscan Esaote, Genoa, Italy) dedicated extremity MR system was done. Additionally, illustrative comparison with conventional radiography and high-field MR imaging is presented in patients in whom these examinations were also performed. Although motion artifact limited the value of a few studies, in the majority of examinations low-field MR imaging provided diagnostic image quality for the full spectrum of disorders affecting the foot and ankle and seemed to be a feasible alternative to high-field MR imaging in establishing an accurate diagnosis. (orig.)

  17. Internal and external Field of View: computer games and cybersickness

    NARCIS (Netherlands)

    Vries, S.C. de; Bos, J.E.; Emmerik, M.L. van; Groen, E.L.

    2007-01-01

    In an experiment with a computer game environment, we studied the effect of Field-of-View (FOV) on cybersickness. In particular, we examined the effect of differences between the internal FOV (IFOV, the FOV which the graphics generator is using to render its images) and the external FOV (EFOV, the

  18. Behavior of small ferromagnetic particles in traveling magnetic field

    Science.gov (United States)

    Deych, V. G.; Terekhov, V. P.

    1985-03-01

    Forces and moments acting on a magnetizable body in a traveling magnetic field are calculated for a body with dimensions much smaller than the wavelength of the magnetic field. It is assumed that a particle of given linear dimension does not have a constant magnetic moment. The material of a particle is characterized by its magnetic permeability and electrical conductivity. The hypothesis that rotation plays a major role in the behavior of small particles is confirmed and the fact that a small particle rolls on a plane, without sliding, when the surface is perfectly rough, in the opposite direction from which the magnetic field travels is explained. Calculations are based on the magnetohydrodynamic equations for a quasi steady magnetic field, and the induced Foucault eddy currents are considered. The results are applicable to transport of ferrofluids and to such metallurgical devices as separators.

  19. Validation of the GATE Monte Carlo simulation platform for modelling a CsI(Tl) scintillation camera dedicated to small-animal imaging

    International Nuclear Information System (INIS)

    Lazaro, D; Buvat, I; Loudos, G; Strul, D; Santin, G; Giokaris, N; Donnarieix, D; Maigne, L; Spanoudaki, V; Styliaris, S; Staelens, S; Breton, V

    2004-01-01

    Monte Carlo simulations are increasingly used in scintigraphic imaging to model imaging systems and to develop and assess tomographic reconstruction algorithms and correction methods for improved image quantitation. GATE (GEANT4 application for tomographic emission) is a new Monte Carlo simulation platform based on GEANT4 dedicated to nuclear imaging applications. This paper describes the GATE simulation of a prototype of scintillation camera dedicated to small-animal imaging and consisting of a CsI(Tl) crystal array coupled to a position-sensitive photomultiplier tube. The relevance of GATE to model the camera prototype was assessed by comparing simulated 99m Tc point spread functions, energy spectra, sensitivities, scatter fractions and image of a capillary phantom with the corresponding experimental measurements. Results showed an excellent agreement between simulated and experimental data: experimental spatial resolutions were predicted with an error less than 100 μm. The difference between experimental and simulated system sensitivities for different source-to-collimator distances was within 2%. Simulated and experimental scatter fractions in a [98-82 keV] energy window differed by less than 2% for sources located in water. Simulated and experimental energy spectra agreed very well between 40 and 180 keV. These results demonstrate the ability and flexibility of GATE for simulating original detector designs. The main weakness of GATE concerns the long computation time it requires: this issue is currently under investigation by the GEANT4 and the GATE collaborations

  20. Retrieval of Droplet size Density Distribution from Multiple field of view Cross polarized Lidar Signals: Theory and Experimental Validation

    Science.gov (United States)

    2016-06-02

    Retrieval of droplet-size density distribution from multiple-field-of-view cross-polarized lidar signals: theory and experimental validation...Gilles Roy, Luc Bissonnette, Christian Bastille, and Gilles Vallee Multiple-field-of-view (MFOV) secondary-polarization lidar signals are used to...use secondary polarization. A mathematical relation among the PSD, the lidar fields of view, the scattering angles, and the angular depolarization

  1. A spatio-temporally compensated acousto-optic scanner for two-photon microscopy providing large field of view.

    Science.gov (United States)

    Kremer, Y; Léger, J-F; Lapole, R; Honnorat, N; Candela, Y; Dieudonné, S; Bourdieu, L

    2008-07-07

    Acousto-optic deflectors (AOD) are promising ultrafast scanners for non-linear microscopy. Their use has been limited until now by their small scanning range and by the spatial and temporal dispersions of the laser beam going through the deflectors. We show that the use of AOD of large aperture (13mm) compared to standard deflectors allows accessing much larger field of view while minimizing spatio-temporal distortions. An acousto-optic modulator (AOM) placed at distance of the AOD is used to compensate spatial and temporal dispersions. Fine tuning of the AOM-AOD setup using a frequency-resolved optical gating (GRENOUILLE) allows elimination of pulse front tilt whereas spatial chirp is minimized thanks to the large aperture AOD.

  2. Studies of the field-of-view resolution tradeoff in virtual-reality systems

    Science.gov (United States)

    Piantanida, Thomas P.; Boman, Duane; Larimer, James; Gille, Jennifer; Reed, Charles

    1992-01-01

    Most virtual-reality systems use LCD-based displays that achieve a large field-of-view at the expense of resolution. A typical display will consist of approximately 86,000 pixels uniformly distributed over an 80-degree by 60-degree image. Thus, each pixel subtends about 13 minutes of arc at the retina; about the same as the resolvable features of the 20/200 line of a Snellen Eye Chart. The low resolution of LCD-based systems limits task performance in some applications. We have examined target-detection performance in a low-resolution virtual world. Our synthesized three-dimensional virtual worlds consisted of target objects that could be positioned at a fixed distance from the viewer, but at random azimuth and constrained elevation. A virtual world could be bounded by chromatic walls or by wire-frame, or it could be unbounded. Viewers scanned these worlds and indicated by appropriate gestures when they had detected the target object. By manipulating the viewer's field size and the chromatic and luminance contrast of annuli surrounding the field-of-view, we were able to assess the effect of field size on the detection of virtual objects in low-resolution synthetic worlds.

  3. The effect of internal and external fields of view on visually induced motion sickness

    NARCIS (Netherlands)

    Bos, J.E.; Vries, S.C. de; Emmerik, M.L. van; Groen, E.L.

    2010-01-01

    Field of view (FOV) is said to affect visually induced motion sickness. FOV, however, is characterized by an internal setting used by the graphics generator (iFOV) and an external factor determined by screen size and viewing distance (eFOV). We hypothesized that especially the incongruence between

  4. The motivations and methodology for high-throughput PET imaging of small animals in cancer research

    Energy Technology Data Exchange (ETDEWEB)

    Aide, Nicolas [Francois Baclesse Cancer Centre, Nuclear Medicine Department, Caen Cedex (France); Caen University, BioTICLA team, EA 4656, IFR 146, Caen (France); Visser, Eric P. [Radboud University Nijmegen Medical Center, Nuclear Medicine Department, Nijmegen (Netherlands); Lheureux, Stephanie [Caen University, BioTICLA team, EA 4656, IFR 146, Caen (France); Francois Baclesse Cancer Centre, Clinical Research Unit, Caen (France); Heutte, Natacha [Francois Baclesse Cancer Centre, Clinical Research Unit, Caen (France); Szanda, Istvan [King' s College London, Division of Imaging Sciences and Biomedical Engineering, London (United Kingdom); Hicks, Rodney J. [Peter MacCallum Cancer Centre, Centre for Molecular Imaging, East Melbourne (Australia)

    2012-09-15

    Over the last decade, small-animal PET imaging has become a vital platform technology in cancer research. With the development of molecularly targeted therapies and drug combinations requiring evaluation of different schedules, the number of animals to be imaged within a PET experiment has increased. This paper describes experimental design requirements to reach statistical significance, based on the expected change in tracer uptake in treated animals as compared to the control group, the number of groups that will be imaged, and the expected intra-animal variability for a given tracer. We also review how high-throughput studies can be performed in dedicated small-animal PET, high-resolution clinical PET systems and planar positron imaging systems by imaging more than one animal simultaneously. Customized beds designed to image more than one animal in large-bore small-animal PET scanners are described. Physics issues related to the presence of several rodents within the field of view (i.e. deterioration of spatial resolution and sensitivity as the radial and the axial offsets increase, respectively, as well as a larger effect of attenuation and the number of scatter events), which can be assessed by using the NEMA NU 4 image quality phantom, are detailed. (orig.)

  5. Real-time RGB-D image stitching using multiple Kinects for improved field of view

    Directory of Open Access Journals (Sweden)

    Hengyu Li

    2017-03-01

    Full Text Available This article concerns the problems of a defective depth map and limited field of view of Kinect-style RGB-D sensors. An anisotropic diffusion based hole-filling method is proposed to recover invalid depth data in the depth map. The field of view of the Kinect-style RGB-D sensor is extended by stitching depth and color images from several RGB-D sensors. By aligning the depth map with the color image, the registration data calculated by registering color images can be used to stitch depth and color images into a depth and color panoramic image concurrently in real time. Experiments show that the proposed stitching method can generate a RGB-D panorama with no invalid depth data and little distortion in real time and can be extended to incorporate more RGB-D sensors to construct even a 360° field of view panoramic RGB-D image.

  6. Health Effects of Occupational Exposure to Electromagnetic Fields in View of Studies Performed in Poland and Abroad

    International Nuclear Information System (INIS)

    Sobiczewska, E.; Szmigielski, S.

    2007-01-01

    The review presents modern views on the assessment of bio effects and health risk in workers exposed to different intensities of electromagnetic fields (EMFs). The review of studies carried out in Poland and abroad reveals that non-specific symptoms and functional disturbances of various physiological systems may develop in persons exposed to EMF of intensities below international safety recommendations, however exact EMF threshold values responsible for inducing these responses are not known. There areno valid data on the possibility of increased risk of various diseases, including cancer, in workers exposed to EMFs. However, hints that the increased morbidity is possible in small groups of workers with long-term exposure to high intensities of EMFs do exist. (author)

  7. Molecular imaging of small animals with dedicated PET tomographs

    International Nuclear Information System (INIS)

    Chatziioannou, A.F.

    2002-01-01

    Biological discovery has moved at an accelerated pace in recent years, with a considerable focus on the transition from in vitro to in vivo models. As a result, there has been a significant increase in the need to adapt clinical imaging methods, as well as for novel imaging technologies for biological research. Positron emission tomography (PET) is a clinical imaging modality that permits the use of positron-labeled molecular imaging probes for non-invasive assays of biochemical processes. The imaging procedure can be repeatedly performed before and after interventions, thereby allowing each animal to be used as its own control. Positron-labeled compounds that target a range of molecular targets have been and continue to be synthesized, with examples of biological processes ranging from receptors and synthesis of transmitters in cell communication, to metabolic processes and gene expression. In animal research, PET has been used extensively in the past for studies of non-human primates and other larger animals. New detector technology has improved spatial resolution, and has made possible PET scanning for the study of the most important modern molecular biology model, the laboratory mouse. This paper presents the challenges facing PET technology as applied to small animal imaging, provides a historical overview of the development of small animal PET systems, and discusses the current state of the art in small animal PET technology. (orig.)

  8. A phase transition between small- and large-field models of inflation

    International Nuclear Information System (INIS)

    Itzhaki, Nissan; Kovetz, Ely D

    2009-01-01

    We show that models of inflection point inflation exhibit a phase transition from a region in parameter space where they are of large-field type to a region where they are of small-field type. The phase transition is between a universal behavior, with respect to the initial condition, at the large-field region and non-universal behavior at the small-field region. The order parameter is the number of e-foldings. We find integer critical exponents at the transition between the two phases.

  9. Wide Field-of-View Soft X-Ray Imaging for Solar Wind-Magnetosphere Interactions

    Science.gov (United States)

    Walsh, B. M.; Collier, M. R.; Kuntz, K. D.; Porter, F. S.; Sibeck, D. G.; Snowden, S. L.; Carter, J. A.; Collado-Vega, Y.; Connor, H. K.; Cravens, T. E.; hide

    2016-01-01

    Soft X-ray imagers can be used to study the mesoscale and macroscale density structures that occur whenever and wherever the solar wind encounters neutral atoms at comets, the Moon, and both magnetized and unmagnetized planets. Charge exchange between high charge state solar wind ions and exospheric neutrals results in the isotropic emission of soft X-ray photons with energies from 0.1 to 2.0 keV. At Earth, this process occurs primarily within the magnetosheath and cusps. Through providing a global view, wide field-of-view imaging can determine the significance of the various proposed solar wind-magnetosphere interaction mechanisms by evaluating their global extent and occurrence patterns. A summary of wide field-of-view (several to tens of degrees) soft X-ray imaging is provided including slumped micropore microchannel reflectors, simulated images, and recent flight results.

  10. SU-E-T-471: Small Field Jaw/MLC Reference Data

    International Nuclear Information System (INIS)

    Kerns, J; Alvarez, P; Followill, D; Lowenstein, J; Molineu, A; Summers, P; Kry, S

    2014-01-01

    Purpose: In recent years the need for small field data of MLCs has increased due to the use of intensity-modulated radiation (IMRT), but moreover the use of stereotactic body radiation (SBRT) has increased, which uses not simply small field sizes, but small jaw and field sizes together. Having reference data for these small fields that is reliable would be invaluable to the physics community. Our study has gathered these values and the data distributions from the Radiological Physics Center's (RPC) site visits between 1990 and the present. Methods: For all measurements, the RPC used a 25 × 25 × 25cm water phantom placed at 100cm SSD. All measurements were made with an Exradin A16 cylindrical ion chamber at an effective depth of 10 cm. A total of 42 Varian machine measurements were used to compose the data for a 6 MV beam and 5 TrueBeam 6 MV flattening filter free (FFF) beams were used for FFF data. Results: Jaw/MLC fields were measured for both 6 MV and 6 MF FFF beams with the jaws and MLCs both at the following field sizes: 6×6, 4×4, 3×3, and 2×2cm. Measurements were normalized to the 10×10 field readings (defined by the jaws and MLC). Spread in the data was minimal and demonstrates a high level of accuracy of acquired data. Conclusion: Small field Jaw/MLC reference data for Varian 6MV and 6 MV FFF beams has been analyzed and presented here, composed of the aggregation of numerous RPC site visits. Obtaining reliable small field data remains difficult, however the RPC has collected high fidelity small field Jaw/MLC data. The data are presented as a reference along with their distributions, in such a way that the physicist can act based upon their own desired agreement with the reference data

  11. Minor actinide burning in dedicated lead-bismuth cooled fast reactors

    International Nuclear Information System (INIS)

    Hejzlar, P.; Driscoll, M.J.; Kazimi, M.S.; Todreas, N.E.

    2001-01-01

    The destruction of minor actinides (MA) in dedicated burners is of contemporary interest in Europe and Japan because it requires the deployment of smaller number of special transmutation facilities. A major fraction of Pu from spent LWR fuel can be then burned in PWRs (or fast reactors) using dedicated fertile-free fuel assemblies. However, the design of MA burning fast spectrum cores poses significant challenges because of deterioration of key safety parameters, in particular of the coolant void coefficient. This study proposes the concept of an lead-bismuth eutectic (LBE)-cooled dedicated MA burner having metallic fuel (MA-Pu-Zr) and streaming assemblies to attain acceptable coolant void worth performance. It is shown that a large 1800 MWth fertile-free core containing 37 wt% TRU with very high fraction of MA(59 wt%) from LWR spent fuel can be burned in a first cycle for 700 EFPDs with a very small reactivity swing: less than β eff . Moreover, the reactivity void worth is negative for a fully voided core when all surrounding coolant is kept at reference density. However, the core reactivity increases as coolant density falls from the reference value of 10.25 to 6 g/cm 3 . Because its coolant density coefficient value is less than that of a sodium cooled IFR, the concept provides good potential for the achievement of self-regulation characteristics in unprotected events, provided that small negative fuel temperature feedback can be maintained. (authors)

  12. Performance Modelling of Automatic Identification System with Extended Field of View

    DEFF Research Database (Denmark)

    Lauersen, Troels; Mortensen, Hans Peter; Pedersen, Nikolaj Bisgaard

    2010-01-01

    This paper deals with AIS (Automatic Identification System) behavior, to investigate the severity of packet collisions in an extended field of view (FOV). This is an important issue for satellite-based AIS, and the main goal is a feasibility study to find out to what extent an increased FOV...

  13. Small-scale gradients of charged particles in the heliospheric magnetic field

    International Nuclear Information System (INIS)

    Guo, Fan; Giacalone, Joe

    2014-01-01

    Using numerical simulations of charged-particles propagating in the heliospheric magnetic field, we study small-scale gradients, or 'dropouts,' in the intensity of solar energetic particles seen at 1 AU. We use two turbulence models, the foot-point random motion model and the two-component model, to generate fluctuating magnetic fields similar to spacecraft observations at 1 AU. The turbulence models include a Kolmogorov-like magnetic field power spectrum containing a broad range of spatial scales from those that lead to large-scale field-line random walk to small scales leading to resonant pitch-angle scattering of energetic particles. We release energetic protons (20 keV-10 MeV) from a spatially compact and instantaneous source. The trajectories of energetic charged particles in turbulent magnetic fields are numerically integrated. Spacecraft observations are mimicked by collecting particles in small windows when they pass the windows at a distance of 1 AU. We show that small-scale gradients in the intensity of energetic particles and velocity dispersions observed by spacecraft can be reproduced using the foot-point random motion model. However, no dropouts are seen in simulations using the two-component magnetic turbulence model. We also show that particle scattering in the solar wind magnetic field needs to be infrequent for intensity dropouts to form.

  14. Effect of age and pop out distracter on attended field of view.

    Science.gov (United States)

    Babu, Raiju J; Leat, Susan J; Irving, Elizabeth L

    2014-01-01

    To investigate the functional field of view (FFOV) of younger and older individuals using the attended field of view (AFOV), a method which allows for eye and head movement. The impact of a pop out distracter and a dual task on the FFOV measure was also investigated. Nine young adult (25±6 years) and 9 older participants (72±4 years) took part in the experiment. The AFOV test involved the binocular detection and localization of a white target (Landolt-C) in a field of 24 white rings (distracters). The further AFOV tests were modified to include the presence of a pop out distracter, a dual task condition, and a combination of the two. Older observers had lower viewing efficiency (log [1/presentation time]) in all conditions (pooled mean across conditions: older: 0.05±0.02; younger: 0.48±0.04) than the younger group. The addition of dual or a pop out distracter did not affect the older group (mean difference ∼104±150ms and ∼124±122ms respectively) but the additional pop out distracter reduced the efficiency of the younger group for targets near fixation (mean difference ∼68±35ms). Better viewing efficiency was observed in younger individuals compared to older individuals. Difficulty in disregarding irrelevant stimuli and thereby resorting to inefficient search strategy is proposed as the reason for the differences. The finding that both older and younger individuals are not affected significantly by the presence of the irrelevant pop out distracter has implications in situations such as driving or hazard avoidance. In such scenarios, search performance is likely not impaired beyond what is found with distracters (visual clutter) in the environment. Copyright © 2013 Spanish General Council of Optometry. Published by Elsevier Espana. All rights reserved.

  15. Fiber-Coupled Wide Field of View Optical Receiver for High Speed Space Communication

    Science.gov (United States)

    Suddath, Shannon N.

    Research groups at NASA Glenn Research Center are interested in improving data rates on the International Space Station (ISS) using a free-space optical (FSO) link. However, known flexure of the ISS structure is expected to cause misalignment of the FSO link. Passive-control designs for mitigating misalignment are under investigation, including using a fiber-bundle for improved field of view. The designs must overcome the obstacle of coupling directly to fiber, rather than a photodetector, as NASA will maintain the use of small form-factor pluggable optical transceivers (SFPs) in the ISS network. In this thesis, a bundle-based receiver capable of coupling directly to fiber is designed, simulated, and tested in lab. Two 3-lens systems were evaluated for power performance in the lab, one with a 20 mm focal length aspheric lens and the other with a 50 mm focal length aspheric lens. The maximum output power achieved was 8 muW.

  16. Dedication

    OpenAIRE

    2013-01-01

    This work is dedicated, to my mom, Bridget, and my dad, (the late) Daniel Enwerem, who taught me to respect people but not fear them; and to those who are engaged or have been victims in the struggle for an egalitarian society in Nigeria.

  17. Comparative study of energy conversion system dedicated to a small wind turbine

    International Nuclear Information System (INIS)

    Mirecki, A.

    2005-01-01

    This study presents a comparison of architectures and strategies of energy management dedicated to VAWT turbines such as Savonius. A Maximum Power Point Tracking must be implemented in order to optimize the energetic behavior. A torque or a speed control, or an indirect control of the DC bus current is possible. In the fact that the wind turbine characteristic is unknown, an operational research based on fuzzy logic is proposed. Aiming to minimize the cost of the static conversion structure, simple structures (diode bridge inverter, associated with DC-DC chopper) are analyzed and compared with a system based on a PWM Voltage Source Inverter. A test bench has been realized in the meantime as a system simulation. Comparisons of the provided energy are made for different wind speeds allowing to evaluate the performance of each structure and of the control strategies. (author)

  18. Dose profile analysis of small fields in intensity modulated radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Medel B, E. [IMSS, Centro Medico Nacional Manuel Avila Camacho, Calle 2 Nte. 2004, Barrio de San Francisco, 72090 Puebla, Pue. (Mexico); Tejeda M, G.; Romero S, K., E-mail: romsakaren@gmail.com [Benemerita Universidad Autonoma de Puebla, Facultad de Ciencias Fisico Matematicas, Av. San Claudio y 18 Sur, Ciudad Universitaria, 72570 Puebla, Pue.(Mexico)

    2015-10-15

    Full text: Small field dosimetry is getting a very important worldwide task nowadays. The use of fields of few centimeters is more common with the introduction of sophisticated techniques of radiation therapy, as Intensity Modulated Radiotherapy (IMRT). In our country the implementation of such techniques is just getting started and whit it the need of baseline data acquisition. The dosimetry under small field conditions represents a challenge for the physicists community. In this work, a dose profile analysis was done, using various types of dosimeters for further comparisons. This analysis includes the study of quality parameters as flatness, symmetry, penumbra, and other in-axis measurements. (Author)

  19. Effects of AC Electric Field on Small Laminar Nonpremixed Flames

    KAUST Repository

    Xiong, Yuan

    2015-01-01

    Electric field can be a viable method in controlling various combustion properties. Comparing to traditional actuators, an application of electric field requires very small power consumption. Especially, alternating current (AC) has received

  20. Electromagnetic fields in small systems from a multiphase transport model

    Science.gov (United States)

    Zhao, Xin-Li; Ma, Yu-Gang; Ma, Guo-Liang

    2018-02-01

    We calculate the electromagnetic fields generated in small systems by using a multiphase transport (AMPT) model. Compared to A +A collisions, we find that the absolute electric and magnetic fields are not small in p +Au and d +Au collisions at energies available at the BNL Relativistic Heavy Ion Collider and in p +Pb collisions at energies available at the CERN Large Hadron Collider. We study the centrality dependencies and the spatial distributions of electromagnetic fields. We further investigate the azimuthal fluctuations of the magnetic field and its correlation with the fluctuating geometry using event-by-event simulations. We find that the azimuthal correlation 〈" close="〉cos(ϕα+ϕβ-2 ΨRP)〉">cos2 (ΨB-Ψ2) between the magnetic field direction and the second-harmonic participant plane is almost zero in small systems with high multiplicities, but not in those with low multiplicities. This indicates that the charge azimuthal correlation is not a valid probe to study the chiral magnetic effect (CME) in small systems with high multiplicities. However, we suggest searching for possible CME effects in small systems with low multiplicities.

  1. Dedication increases productivity: an analysis of the implementation of a dedicated medical team in the emergency department.

    Science.gov (United States)

    Ramos, Pedro; Paiva, José Artur

    2017-12-01

    In several European countries, emergency departments (EDs) now employ a dedicated team of full-time emergency medicine (EM) physicians, with a distinct leadership and bed-side emergency training, in all similar to other hospital departments. In Portugal, however, there are still two very different models for staffing EDs: a classic model, where EDs are mostly staffed with young inexperienced physicians from different medical departments who take turns in the ED in 12-h shifts and a dedicated model, recently implemented in some hospitals, where the ED is staffed by a team of doctors with specific medical competencies in emergency medicine that work full-time in the ED. Our study assesses the effect of an intervention in a large academic hospital ED in Portugal in 2002, and it is the first to test the hypothesis that implementing a dedicated team of doctors with EM expertise increases the productivity and reduces costs in the ED, maintaining the quality of care provided to patients. A pre-post design was used for comparing the change on the organisational model of delivering care in our medical ED. All emergency medical admissions were tracked in 2002 (classic model with 12-h shift in the ED) and 2005/2006 (dedicated team with full-time EM physicians), and productivity, costs with medical human resources and quality of care measures were compared. We found that medical productivity (number of patients treated per hour of medical work) increased dramatically after the creation of the dedicated team (X 2 KW = 31.135; N = 36; p work reduced both in regular hours and overtime. Moreover, hospitalisation rates decreased and the length of stay in the ED increased significantly after the creation of the dedicated team. Implementing a dedicated team of doctors increased the medical productivity and reduced costs in our ED. Our findings have straightforward implication for Portuguese policymakers aiming at reducing hospital costs while coping with increased ED demand.

  2. Optical design of an athermalised dual field of view step zoom optical system in MWIR

    Science.gov (United States)

    Kucukcelebi, Doruk

    2017-08-01

    In this paper, the optical design of an athermalised dual field of view step zoom optical system in MWIR (3.7μm - 4.8μm) is described. The dual field of view infrared optical system is designed based on the principle of passive athermalization method not only to achieve athermal optical system but also to keep the high image quality within the working temperature between -40°C and +60°C. The infrared optical system used in this study had a 320 pixel x 256 pixel resolution, 20μm pixel pitch size cooled MWIR focal plane array detector. In this study, the step zoom mechanism, which has the axial motion due to consisting of a lens group, is considered to simplify mechanical structure. The optical design was based on moving a single lens along the optical axis for changing the optical system's field of view not only to reduce the number of moving parts but also to athermalize for the optical system. The optical design began with an optimization process using paraxial optics when first-order optics parameters are determined. During the optimization process, in order to reduce aberrations, such as coma, astigmatism, spherical and chromatic aberrations, aspherical surfaces were used. As a result, athermalised dual field of view step zoom optical design is proposed and the performance of the design using proposed method was verified by providing the focus shifts, spot diagrams and MTF analyzes' plots.

  3. Traversing field of view and AR-PIV for mid-field wake vortex investigation in a towing tank

    Science.gov (United States)

    Scarano, F.; van Wijk, C.; Veldhuis, L. L. M.

    2002-08-01

    Wake vortex flow experiments are performed in a water tank where a 1:48 scaled model of a large transport aircraft A340-300 is towed at the speed of 3 and 5 ms-1 with values of the angle of attack α={2°, 4°, 8°}. Particle image velocimetry (PIV) measurements are performed in a plane perpendicular to the towing direction describing the streamwise component of the wake vorticity. The instantaneous field of view (I-FOV) is traversed vertically with an underwater moving-camera device tracking the vortex core during the downward motion. An adaptive resolution (AR) image-processing technique is introduced that enhances the PIV interrogation in terms of spatial resolution and accuracy. The main objectives of the investigation are to demonstrate the applicability of PIV diagnostics in wake vortex research with towing-tank facilities. The specific implementation of the traversing field-of-view (T-FOV) technique and the AR image processing are driven by the need to characterize the vortex wake global properties as well as the vortex decay phenomenon in the mid- and far-field. Relevant aerodynamic information is obtained in the mid-field where the time evolution of the vortex structure (core radius and tangential velocity) and of the overall vortex wake (vortex trajectory, descent velocity, circulation) are discussed.

  4. TH-EF-204-03: Determination of Small Field Output Factors, Advantages and Limitations of Monte Carlo Simulation

    International Nuclear Information System (INIS)

    Vaque, J. Puxeu

    2016-01-01

    Joanna E. Cygler, Jan Seuntjens, J. Daniel Bourland, M. Saiful Huq, Josep Puxeu Vaque, Daniel Zucca Aparicio, Tatiana Krylova, Yuri Kirpichev, Eric Ford, Caridad Borras Stereotactic Radiation Therapy (SRT) utilizes small static and dynamic (IMRT) fields, to successfully treat malignant and benign diseases using techniques such as Stereotactic Radiosurgery (SRS) and Stereotactic Body Radiation Therapy (SBRT). SRT is characterized by sharp dose gradients for individual fields and their resultant dose distributions. For appropriate targets, small field radiotherapy offers improved treatment quality by allowing better sparing of organs at risk while delivering the prescribed target dose. Specialized small field treatment delivery systems, such as robotic-controlled linear accelerators, gamma radiosurgery units, and dynamic arc linear accelerators may utilize rigid fixation, image guidance, and tumor tracking, to insure precise dose delivery to static or moving targets. However, in addition to great advantages, small field delivery techniques present special technical challenges for dose calibration due to unique geometries and small field sizes not covered by existing reference dosimetry protocols such as AAPM TG-51 or IAEA TRS 398. In recent years extensive research has been performed to understand small field dosimetry and measurement instrumentation. AAPM, IAEA and ICRU task groups are expected to provide soon recommendations on the dosimetry of small radiation fields. In this symposium we will: 1] discuss the physics, instrumentation, methodologies and challenges for small field radiation dose measurements; 2] review IAEA and ICRU recommendations on prescribing, recording and reporting of small field radiation therapy; 3] discuss selected clinical applications and technical aspects for specialized image-guided, small field, linear accelerator based treatment techniques such as IMRT and SBRT. Learning Objectives: To learn the physics of small fields in contrast to

  5. TH-EF-204-03: Determination of Small Field Output Factors, Advantages and Limitations of Monte Carlo Simulation

    Energy Technology Data Exchange (ETDEWEB)

    Vaque, J. Puxeu [Institut Catala d’Oncologia (Spain)

    2016-06-15

    Joanna E. Cygler, Jan Seuntjens, J. Daniel Bourland, M. Saiful Huq, Josep Puxeu Vaque, Daniel Zucca Aparicio, Tatiana Krylova, Yuri Kirpichev, Eric Ford, Caridad Borras Stereotactic Radiation Therapy (SRT) utilizes small static and dynamic (IMRT) fields, to successfully treat malignant and benign diseases using techniques such as Stereotactic Radiosurgery (SRS) and Stereotactic Body Radiation Therapy (SBRT). SRT is characterized by sharp dose gradients for individual fields and their resultant dose distributions. For appropriate targets, small field radiotherapy offers improved treatment quality by allowing better sparing of organs at risk while delivering the prescribed target dose. Specialized small field treatment delivery systems, such as robotic-controlled linear accelerators, gamma radiosurgery units, and dynamic arc linear accelerators may utilize rigid fixation, image guidance, and tumor tracking, to insure precise dose delivery to static or moving targets. However, in addition to great advantages, small field delivery techniques present special technical challenges for dose calibration due to unique geometries and small field sizes not covered by existing reference dosimetry protocols such as AAPM TG-51 or IAEA TRS 398. In recent years extensive research has been performed to understand small field dosimetry and measurement instrumentation. AAPM, IAEA and ICRU task groups are expected to provide soon recommendations on the dosimetry of small radiation fields. In this symposium we will: 1] discuss the physics, instrumentation, methodologies and challenges for small field radiation dose measurements; 2] review IAEA and ICRU recommendations on prescribing, recording and reporting of small field radiation therapy; 3] discuss selected clinical applications and technical aspects for specialized image-guided, small field, linear accelerator based treatment techniques such as IMRT and SBRT. Learning Objectives: To learn the physics of small fields in contrast to

  6. Large-field-of-view imaging by multi-pupil adaptive optics.

    Science.gov (United States)

    Park, Jung-Hoon; Kong, Lingjie; Zhou, Yifeng; Cui, Meng

    2017-06-01

    Adaptive optics can correct for optical aberrations. We developed multi-pupil adaptive optics (MPAO), which enables simultaneous wavefront correction over a field of view of 450 × 450 μm 2 and expands the correction area to nine times that of conventional methods. MPAO's ability to perform spatially independent wavefront control further enables 3D nonplanar imaging. We applied MPAO to in vivo structural and functional imaging in the mouse brain.

  7. Dedicated accelerator and microprobe line

    International Nuclear Information System (INIS)

    Malmqvist, K.G.; Hylten, G.; Hult, M.; Haakansson, K.; Knox, J.M.; Larsson, N.P.O.; Nilsson, C.; Pallon, J.; Schofield, R.; Swietlicki, E.; Tapper, U.A.S.; Yang Changyi

    1993-01-01

    The development of a dedicated facility for nuclear microprobe analysis and the experiences from using it are discussed. The general properties of the present Lund nuclear microprobe will be described and the advantages of using a dedicated accelerator discussed. (orig.)

  8. Monte Carlo modeling of small photon fields: Quantifying the impact of focal spot size on source occlusion and output factors, and exploring miniphantom design for small-field measurements

    International Nuclear Information System (INIS)

    Scott, Alison J. D.; Nahum, Alan E.; Fenwick, John D.

    2009-01-01

    The accuracy with which Monte Carlo models of photon beams generated by linear accelerators (linacs) can describe small-field dose distributions depends on the modeled width of the electron beam profile incident on the linac target. It is known that the electron focal spot width affects penumbra and cross-field profiles; here, the authors explore the extent to which source occlusion reduces linac output for smaller fields and larger spot sizes. A BEAMnrc Monte Carlo linac model has been used to investigate the variation in penumbra widths and small-field output factors with electron spot size. A formalism is developed separating head scatter factors into source occlusion and flattening filter factors. Differences between head scatter factors defined in terms of in-air energy fluence, collision kerma, and terma are explored using Monte Carlo calculations. Estimates of changes in kerma-based source occlusion and flattening filter factors with field size and focal spot width are obtained by calculating doses deposited in a narrow 2 mm wide virtual ''milliphantom'' geometry. The impact of focal spot size on phantom scatter is also explored. Modeled electron spot sizes of 0.4-0.7 mm FWHM generate acceptable matches to measured penumbra widths. However the 0.5 cm field output factor is quite sensitive to electron spot width, the measured output only being matched by calculations for a 0.7 mm spot width. Because the spectra of the unscattered primary (Ψ Π ) and head-scattered (Ψ Σ ) photon energy fluences differ, miniphantom-based collision kerma measurements do not scale precisely with total in-air energy fluence Ψ=(Ψ Π +Ψ Σ ) but with (Ψ Π +1.2Ψ Σ ). For most field sizes, on-axis collision kerma is independent of the focal spot size; but for a 0.5 cm field size and 1.0 mm spot width, it is reduced by around 7% mostly due to source occlusion. The phantom scatter factor of the 0.5 cm field also shows some spot size dependence, decreasing by 6% (relative) as

  9. Exploring experts' views and perspectives on the enhancement of Strategic Environmental Assessment in European small islands

    International Nuclear Information System (INIS)

    Polido, Alexandra; João, Elsa; Ramos, Tomás B.

    2016-01-01

    Small islands have the attention of the international community because they are territories with unique features, and a pressing need for the enhancement of sustainability. Strategic Environmental Assessment (SEA) has characteristics that may promote the development and improvement of sustainability in these territories: (i) changing the mind-set, and the decision-making and institutional paradigm, (ii) facilitating cooperation and coordination between different stakeholders, and (iii) providing a framework for good governance and community empowerment. The scientific literature suggests that there may be a need for context-specific SEA in these territories. However, SEA studies often do not incorporate local contextual information, including intuitive knowledge and sense of place. Therefore, there is a possible gap between what is found in the literature and what local communities think, including different stakeholders and experts. Hence, the main goal of this research was to gain an insight into the views and perspectives of small islands SEA experts about issues related to SEA in European small islands, including context-specific approaches, as well as the contribution of SEA for sustainability in these territories. To achieve the research aim, exploratory research using a questionnaire-based survey was designed, aimed at experts on SEA in European small islands. Findings showed regional cooperation networks may have a fundamental role when developing SEA-specific approaches in these territories. This is because SEA-specific approaches encourage a joint effort among islands within one region to improve SEA capacity-building, develop and share a baseline information system, and to share and exchange resources, overall. Also, guidelines are preferred among experts over more legal frameworks and regulations. Finally, the research showed that experts view SEA as a way to enhance sustainability in small islands. This study highlights the importance of integrating

  10. Spiral CT of the pancreas. The value of small field-of-view targeted reconstruction

    International Nuclear Information System (INIS)

    Nishiharu, T.; Yamashita, Y.; Ogata, I.; Sumi, S.; Mitsuzaki, K.; Takahashi, M.

    1998-01-01

    Purpose: To compare the value of a retrospective targeted high-resolution spiral CT to the standard reconstruction technique in the assessment of pancreatic diseases. Material and methods: Spiral CT pancreatic images of a standard-size reconstruction protocol were compared prospectively with those of a retrospective targeted high-spatial-resolution reconstruction protocol in 30 patients. Prior to clinical evaluation, a phantom study was performed to evaluate the spatial resolution and signal-to-noise ratio of both protocols. Results: The high-resolution protocol achieved a good signal-to-noise ratio with acceptable spatial resolution. Phantom studies revealed increased image noise (+17%) with an increase in spatial resolution (+100%). In patients studied with the high-resolution protocol, the increase in noise was not significant but there was a marked improvement in the definition of small details. Conclusion: Images obtained with a targeted high-spatial-resolution reconstruction protocol showed superior lesion definition and vascular opacification compared with those obtained with a standard-size reconstruction protocol. This technique may have potential in the evaluation of small pancreatic abnormalities. (orig.)

  11. Smokefree signage at children's playgrounds: Field observations and comparison with Google Street View.

    Science.gov (United States)

    Thomson, George; Wilson, Nick

    2017-01-01

    Although there is global growth in outdoor smokefree areas, little is known about the associated smokefree signage. We aimed to study smokefree signage at playgrounds and to compare field observations with images from Google Street View (GSV). We randomly selected playgrounds in 21 contiguous local government areas in the lower North Island of New Zealand, all of which had smokefree playground policies. Field data were collected on smokefree signage along with dog control signage to allow for comparisons. The sensitivity and specificity of using GSV for data collection were calculated. Out of the 63 playgrounds studied, only 44% (95% CI: 33%-57%) had any smokefree signage within 10 m of the playground equipment. The mean number of such signs was 0.8 per playground (range: 0 to 6). Sign size varied greatly from 42 cm 2 up to 2880 cm 2 ; but was typically fairly small (median = 600 cm 2 ; ie, as per a 20 × 30 cm rectangle). Qualitatively the dog signs appeared to use clearer images and were less wordy than the smokefree signs. Most playground equipment (82%), could be seen on GSV, but for these settings the sensitivity for identifying smokefree signs was poor at 16%. Yet specificity was reasonable at 96%. The presence and quality of smokefree signage was poor in this sample of children's playgrounds in this developed country setting. There appears to be value in comparing smokefree signage with other types of signage (eg, dog control signage). Google Street View was not a sensitive tool for studying such signage.

  12. A practical and theoretical definition of very small field size for radiotherapy output factor measurements.

    Science.gov (United States)

    Charles, P H; Cranmer-Sargison, G; Thwaites, D I; Crowe, S B; Kairn, T; Knight, R T; Kenny, J; Langton, C M; Trapp, J V

    2014-04-01

    This work introduces the concept of very small field size. Output factor (OPF) measurements at these field sizes require extremely careful experimental methodology including the measurement of dosimetric field size at the same time as each OPF measurement. Two quantifiable scientific definitions of the threshold of very small field size are presented. A practical definition was established by quantifying the effect that a 1 mm error in field size or detector position had on OPFs and setting acceptable uncertainties on OPF at 1%. Alternatively, for a theoretical definition of very small field size, the OPFs were separated into additional factors to investigate the specific effects of lateral electronic disequilibrium, photon scatter in the phantom, and source occlusion. The dominant effect was established and formed the basis of a theoretical definition of very small fields. Each factor was obtained using Monte Carlo simulations of a Varian iX linear accelerator for various square field sizes of side length from 4 to 100 mm, using a nominal photon energy of 6 MV. According to the practical definition established in this project, field sizes ≤ 15 mm were considered to be very small for 6 MV beams for maximal field size uncertainties of 1 mm. If the acceptable uncertainty in the OPF was increased from 1.0% to 2.0%, or field size uncertainties are 0.5 mm, field sizes ≤ 12 mm were considered to be very small. Lateral electronic disequilibrium in the phantom was the dominant cause of change in OPF at very small field sizes. Thus the theoretical definition of very small field size coincided to the field size at which lateral electronic disequilibrium clearly caused a greater change in OPF than any other effects. This was found to occur at field sizes ≤ 12 mm. Source occlusion also caused a large change in OPF for field sizes ≤ 8 mm. Based on the results of this study, field sizes ≤ 12 mm were considered to be theoretically very small for 6 MV beams. Extremely

  13. Frontier Fields: Bringing the Distant Universe into View

    Science.gov (United States)

    Eisenhamer, Bonnie; Lawton, Brandon L.; Summers, Frank; Ryer, Holly

    2014-06-01

    The Frontier Fields is a multi-cycle program of six deep-field observations of strong-lensing galaxy clusters that will be taken in parallel with six deep “blank fields.” The three-year long collaborative program centers on observations from NASA’s Great Observatories, who will team up to look deeper into the universe than ever before, and potentially uncover galaxies that are as much as 100 times fainter than what the telescopes can typically see. Because of the unprecedented views of the universe that will be achieved, the Frontier Fields science program is ideal for informing audiences about scientific advances and topics in STEM. For example, the program provides an opportunity to look back on the history of deep field observations and how they changed (and continue to change) astronomy, while exploring the ways astronomers approach big science problems. As a result, the Space Telescope Science Institute’s Office of Public Outreach has initiated an education and public outreach (E/PO) project to follow the progress of the Frontier Fields program - providing a behind-the-scenes perspective of this observing initiative. This poster will highlight the goals of the Frontier Fields E/PO project and the cost-effective approach being used to bring the program’s results to both the public and educational audiences.

  14. Dynamics of cell and tissue growth acquired by means of extended field of view lensfree microscopy.

    Science.gov (United States)

    Momey, F; Coutard, J-G; Bordy, T; Navarro, F; Menneteau, M; Dinten, J-M; Allier, C

    2016-02-01

    In this paper, we discuss a new methodology based on lensfree imaging to perform wound healing assay with unprecedented statistics. Our video lensfree microscopy setup is a simple device featuring only a CMOS sensor and a semi coherent illumination system. Yet it is a powerful mean for the real-time monitoring of cultivated cells. It presents several key advantages, e.g. integration into standard incubator, compatibility with standard cell culture protocol, simplicity and ease of use. It can perform the follow-up in a large field of view (25 mm(2)) of several crucial parameters during the culture of cells i.e. their motility, their proliferation rate or their death. Consequently the setup can gather large statistics both in space and time. Here we uses this facility in the context of wound healing assay to perform label-free measurements of the velocities of the fronts of proliferation of the cell layer as a function of time by means of particle image velocimetry (PIV) processing. However, for such tissue growth experiments, the field of view of 25 mm(2) remains not sufficient and results can be biased depending on the position of the device with respect to the recipient of the cell culture. Hence, to conduct exhaustive wound healing assays, we propose to enlarge the field of view up to 10 cm(2) through a raster scan, by moving the source/sensor with respect to the Petri dish. We have performed acquisitions of wound healing assay (keratinocytes HaCaT) both in real-time (25 mm(2)) and in final point (10 cm(2)) to assess the combination of velocimetry measurements and final point wide field imaging. In the future, we aim at combining directly our extended field of view acquisitions (>10 cm(2)) with real time ability inside the incubator.

  15. The evolution of the small business and entrepreneurship field: A bibliometric investigation of articles published in the International Small Business Journal

    OpenAIRE

    Volery, Thierry; Mazzarol, Tim

    2015-01-01

    Abstract This article analyses the evolution of the small business management and entrepreneurship fields as reflected in articles published in its premier journal, the International Small Business Journal. It investigates the evolution of the fields through bibliometric examination of all 660 articles published between 1982 and 2012. While small business management has remained the main focus of the journal, there has been a significant growth in the number of articles focusing specif...

  16. Fringe field effects in small rings of large acceptance

    Directory of Open Access Journals (Sweden)

    Martin Berz

    2000-12-01

    Full Text Available Recently there has been renewed interest in the influence of fringe fields on particle dynamics, due to studies that revealed their importance in some cases, as, for example, the proposed Neutrino Factory and muon colliders. In this paper, we present a systematic study of generic fringe field effects. Using as an example a lattice of the proposed Neutrino Factory, we show that fringe fields influence the dynamics of particles at all orders, starting with the linear motion. It is found that the widely used sharp cutoff approximation leads to divergences regardless of the specific fall-off shape of the fields. The results suggest that a careful consideration of fringe field effects in the design stage of small machines for large emittances is always recommended.

  17. Dedicated bifurcation stents

    Directory of Open Access Journals (Sweden)

    Ajith Ananthakrishna Pillai

    2012-03-01

    Full Text Available Bifurcation percutaneous coronary intervention (PCI is still a difficult call for the interventionist despite advancements in the instrumentation, technical skill and the imaging modalities. With major cardiac events relate to the side-branch (SB compromise, the concept and practice of dedicated bifurcation stents seems exciting. Several designs of such dedicated stents are currently undergoing trials. This novel concept and pristine technology offers new hope notwithstanding the fact that we need to go a long way in widespread acceptance and practice of these gadgets. Some of these designs even though looks enterprising, the mere complex delivering technique and the demanding knowledge of the exact coronary anatomy makes their routine use challenging.

  18. Implementation of small field radiotherapy dosimetry for spinal metastase case

    Science.gov (United States)

    Rofikoh, Wibowo, W. E.; Pawiro, S. A.

    2017-07-01

    The main objective of this study was to know dose profile of small field radiotherapy in the spinal metastase case with source axis distance (SAD) techniques. In addition, we evaluated and compared the dose planning of stereotactic body radiation therapy (SBRT) and conventional techniques to measurements with Exradin A16 and Gafchromic EBT3 film dosimeters. The results showed that film EBT3 had a highest precision and accuracy with the average of the standard deviation of ±1.7 and maximum discrepancy of 2.6 %. In addition, the average value of Full Wave Half Maximum (FWHM) and its largest deviation in small field size of 0.8 x 0.8 cm2 are 0.82 cm and 16.3 % respectively, while it was found around 2.36 cm and 3 % for the field size of 2.4 x 2.4 cm2. The comparison between penumbra width and the collimation was around of 37.1 % for the field size of 0.8 x 0.8 cm2, while it was found of 12.4 % for the field size of 2.4 x 2.4 cm2.

  19. Improving the accuracy of ionization chamber dosimetry in small megavoltage x-ray fields

    Science.gov (United States)

    McNiven, Andrea L.

    The dosimetry of small x-ray fields is difficult, but important, in many radiation therapy delivery methods. The accuracy of ion chambers for small field applications, however, is limited due to the relatively large size of the chamber with respect to the field size, leading to partial volume effects, lateral electronic disequilibrium and calibration difficulties. The goal of this dissertation was to investigate the use of ionization chambers for the purpose of dosimetry in small megavoltage photon beams with the aim of improving clinical dose measurements in stereotactic radiotherapy and helical tomotherapy. A new method for the direct determination of the sensitive volume of small-volume ion chambers using micro computed tomography (muCT) was investigated using four nominally identical small-volume (0.56 cm3) cylindrical ion chambers. Agreement between their measured relative volume and ionization measurements (within 2%) demonstrated the feasibility of volume determination through muCT. Cavity-gas calibration coefficients were also determined, demonstrating the promise for accurate ion chamber calibration based partially on muCT. The accuracy of relative dose factor measurements in 6MV stereotactic x-ray fields (5 to 40mm diameter) was investigated using a set of prototype plane-parallel ionization chambers (diameters of 2, 4, 10 and 20mm). Chamber and field size specific correction factors ( CSFQ ), that account for perturbation of the secondary electron fluence, were calculated using Monte Carlo simulation methods (BEAM/EGSnrc simulations). These correction factors (e.g. CSFQ = 1.76 (2mm chamber, 5mm field) allow for accurate relative dose factor (RDF) measurement when applied to ionization readings, under conditions of electronic disequilibrium. With respect to the dosimetry of helical tomotherapy, a novel application of the ion chambers was developed to characterize the fan beam size and effective dose rate. Characterization was based on an adaptation of the

  20. 47 CFR 69.125 - Dedicated signalling transport.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 3 2010-10-01 2010-10-01 false Dedicated signalling transport. 69.125 Section... (CONTINUED) ACCESS CHARGES Computation of Charges § 69.125 Dedicated signalling transport. (a) Dedicated signalling transport shall consist of two elements, a signalling link charge and a signalling transfer point...

  1. HyperCube: A Small Lensless Position Sensing Device for the Tracking of Flickering Infrared LEDs.

    Science.gov (United States)

    Raharijaona, Thibaut; Mignon, Paul; Juston, Raphaël; Kerhuel, Lubin; Viollet, Stéphane

    2015-07-08

    An innovative insect-based visual sensor is designed to perform active marker tracking. Without any optics and a field-of-view of about 60°, a novel miniature visual sensor is able to locate flickering markers (LEDs) with an accuracy much greater than the one dictated by the pixel pitch. With a size of only 1 cm3 and a mass of only 0.33 g, the lensless sensor, called HyperCube, is dedicated to 3D motion tracking and fits perfectly with the drastic constraints imposed by micro-aerial vehicles. Only three photosensors are placed on each side of the cubic configuration of the sensing device, making this sensor very inexpensive and light. HyperCube provides the azimuth and elevation of infrared LEDs flickering at a high frequency (>1 kHz) with a precision of 0.5°. The minimalistic design in terms of small size, low mass and low power consumption of this visual sensor makes it suitable for many applications in the field of the cooperative flight of unmanned aerial vehicles and, more generally, robotic applications requiring active beacons. Experimental results show that HyperCube provides useful angular measurements that can be used to estimate the relative position between the sensor and the flickering infrared markers.

  2. HyperCube: A Small Lensless Position Sensing Device for the Tracking of Flickering Infrared LEDs

    Directory of Open Access Journals (Sweden)

    Thibaut Raharijaona

    2015-07-01

    Full Text Available An innovative insect-based visual sensor is designed to perform active marker tracking. Without any optics and a field-of-view of about 60°, a novel miniature visual sensor is able to locate flickering markers (LEDs with an accuracy much greater than the one dictated by the pixel pitch. With a size of only 1 cm3 and a mass of only 0.33 g, the lensless sensor, called HyperCube, is dedicated to 3D motion tracking and fits perfectly with the drastic constraints imposed by micro-aerial vehicles. Only three photosensors are placed on each side of the cubic configuration of the sensing device, making this sensor very inexpensive and light. HyperCube provides the azimuth and elevation of infrared LEDs flickering at a high frequency (>1 kHz with a precision of 0.5°. The minimalistic design in terms of small size, low mass and low power consumption of this visual sensor makes it suitable for many applications in the field of the cooperative flight of unmanned aerial vehicles and, more generally, robotic applications requiring active beacons. Experimental results show that HyperCube provides useful angular measurements that can be used to estimate the relative position between the sensor and the flickering infrared markers.

  3. TU-CD-207-11: Patient-Driven Automatic Exposure Control for Dedicated Breast CT

    International Nuclear Information System (INIS)

    Hernandez, A; Gazi, P; Seibert, J; Boone, J

    2015-01-01

    Purpose: To implement automatic exposure control (AEC) in dedicated breast CT (bCT) on a patient-specific basis using only the pre-scan scout views. Methods: Using a large cohort (N=153) of bCT data sets, the breast effective diameter (D) and width in orthogonal planes (Wa,Wb) were calculated from the reconstructed bCT image and pre-scan scout views, respectively. D, Wa, and Wb were measured at the breast center-of-mass (COM), making use of the known geometry of our bCT system. These data were then fit to a second-order polynomial “D=F(Wa,Wb)” in a least squares sense in order to provide a functional form for determining the breast diameter. The coefficient of determination (R 2 ) and mean percent error between the measured breast diameter and fit breast diameter were used to evaluate the overall robustness of the polynomial fit. Lastly, previously-reported bCT technique factors derived from Monte Carlo simulations were used to determine the tube current required for each breast diameter in order to match two-view mammographic dose levels. Results: F(Wa,Wb) provided fitted breast diameters in agreement with the measured breast diameters resulting in R 2 values ranging from 0.908 to 0.929 and mean percent errors ranging from 3.2% to 3.7%. For all 153 bCT data sets used in this study, the fitted breast diameters ranged from 7.9 cm to 15.7 cm corresponding to tube current values ranging from 0.6 mA to 4.9 mA in order to deliver the same dose as two-view mammography in a 50% glandular breast with a 80 kV x-ray beam and 16.6 second scan time. Conclusion: The present work provides a robust framework for AEC in dedicated bCT using only the width measurements derived from the two orthogonal pre-scan scout views. Future work will investigate how these automatically chosen exposure levels affect the quality of the reconstructed image

  4. TU-CD-207-11: Patient-Driven Automatic Exposure Control for Dedicated Breast CT

    Energy Technology Data Exchange (ETDEWEB)

    Hernandez, A; Gazi, P [Biomedical Engineering Graduate Group, University of California Davis, Davis, CA (United States); Department of Radiology, UC Davis Medical Center, Sacramento, CA (United States); Seibert, J; Boone, J [Department of Radiology, UC Davis Medical Center, Sacramento, CA (United States); Department of Biomedical Engineering, University of California Davis, Davis, CA (United States)

    2015-06-15

    Purpose: To implement automatic exposure control (AEC) in dedicated breast CT (bCT) on a patient-specific basis using only the pre-scan scout views. Methods: Using a large cohort (N=153) of bCT data sets, the breast effective diameter (D) and width in orthogonal planes (Wa,Wb) were calculated from the reconstructed bCT image and pre-scan scout views, respectively. D, Wa, and Wb were measured at the breast center-of-mass (COM), making use of the known geometry of our bCT system. These data were then fit to a second-order polynomial “D=F(Wa,Wb)” in a least squares sense in order to provide a functional form for determining the breast diameter. The coefficient of determination (R{sup 2}) and mean percent error between the measured breast diameter and fit breast diameter were used to evaluate the overall robustness of the polynomial fit. Lastly, previously-reported bCT technique factors derived from Monte Carlo simulations were used to determine the tube current required for each breast diameter in order to match two-view mammographic dose levels. Results: F(Wa,Wb) provided fitted breast diameters in agreement with the measured breast diameters resulting in R{sup 2} values ranging from 0.908 to 0.929 and mean percent errors ranging from 3.2% to 3.7%. For all 153 bCT data sets used in this study, the fitted breast diameters ranged from 7.9 cm to 15.7 cm corresponding to tube current values ranging from 0.6 mA to 4.9 mA in order to deliver the same dose as two-view mammography in a 50% glandular breast with a 80 kV x-ray beam and 16.6 second scan time. Conclusion: The present work provides a robust framework for AEC in dedicated bCT using only the width measurements derived from the two orthogonal pre-scan scout views. Future work will investigate how these automatically chosen exposure levels affect the quality of the reconstructed image.

  5. Local-Field Distribution of Two Dielectric Inclusions at Small Separation

    Science.gov (United States)

    Siu, Yuet-Lun; Yu, Kin-Wah

    2001-03-01

    When two dielectric inclusions approach to each other in a composite medium, significant mutual polarization effects must occur. These effects are multipolar in nature and are difficult to treat from first principles(J. D. Jackson, Classical Electrodynamics), 2nd edition, (Wiley, New York, 1975).. In this work, we employ the discrete-dipole theory(B. T. Draine and P. J. Flatau, J. Opt. Soc. Am. A 11) 1491 (1994). to account for the mutual polarization effects by dividing the inclusions into many small subparts. We begin the calculation at small inclusion sizes and large separation, where the point-dipole limit being valid, and proceed to larger inclusion sizes and small separation, for which the mutual polarization effect becomes important. Then, we apply the theory to determine the dipole moment of each subpart self-consistently. In this way, each dipole moment yields the local electric field, which in turn polarizes the neighboring dipoles. We also begin the calculation at small inclusion sizes and large separation, where the point-dipole limit being valid, and proceed to larger inclusion sizes and small separation. Our resluts indicate that convergence is achieved with moderate computational effects. The results produce valuable information about the local electric field distribution, which is relevant to optical absorption due to surface phonon-polaritons of ionic microcrystals.

  6. Cost effective nuclear commercial grade dedication

    International Nuclear Information System (INIS)

    Maletz, J.J.; Marston, M.J.

    1991-01-01

    This paper describes a new computerized database method to create/edit/view specification technical data sheets (mini-specifications) for procurement of spare parts for nuclear facility maintenance and to develop information that could support possible future facility life extension efforts. This method may reduce cost when compared with current manual methods. The use of standardized technical data sheets (mini-specifications) for items of the same category improves efficiency. This method can be used for a variety of tasks, including: Nuclear safety-related procurement; Non-safety related procurement; Commercial grade item procurement/dedication; Evaluation of replacement items. This program will assist the nuclear facility in upgrading its procurement activities consistent with the recent NUMARC Procurement Initiative. Proper utilization of the program will assist the user in assuring that the procured items are correct for the applications, provide data to assist in detecting fraudulent materials, minimize human error in withdrawing database information, improve data retrievability, improve traceability, and reduce long-term procurement costs

  7. Exploring experts' views and perspectives on the enhancement of Strategic Environmental Assessment in European small islands

    Energy Technology Data Exchange (ETDEWEB)

    Polido, Alexandra, E-mail: a.polido@campus.fct.unl.pt [CENSE, Center for Environmental and Sustainability Research, Departamento de Ciências e Engenharia do Ambiente, Faculdade de Ciências e Tecnologia, Universidade NOVA de Lisboa, Campus da Caparica, 2829-516 Caparica (Portugal); João, Elsa, E-mail: elsa.joao@strath.ac.uk [Department of Civil and Environmental Engineering, University of Strathclyde, Level 5, James Weir Building, 75 Montrose Street, Glasgow G1 1XJ, Scotland (United Kingdom); Ramos, Tomás B., E-mail: tabr@fct.unl.pt [CENSE, Center for Environmental and Sustainability Research, Departamento de Ciências e Engenharia do Ambiente, Faculdade de Ciências e Tecnologia, Universidade NOVA de Lisboa, Campus da Caparica, 2829-516 Caparica (Portugal)

    2016-04-15

    Small islands have the attention of the international community because they are territories with unique features, and a pressing need for the enhancement of sustainability. Strategic Environmental Assessment (SEA) has characteristics that may promote the development and improvement of sustainability in these territories: (i) changing the mind-set, and the decision-making and institutional paradigm, (ii) facilitating cooperation and coordination between different stakeholders, and (iii) providing a framework for good governance and community empowerment. The scientific literature suggests that there may be a need for context-specific SEA in these territories. However, SEA studies often do not incorporate local contextual information, including intuitive knowledge and sense of place. Therefore, there is a possible gap between what is found in the literature and what local communities think, including different stakeholders and experts. Hence, the main goal of this research was to gain an insight into the views and perspectives of small islands SEA experts about issues related to SEA in European small islands, including context-specific approaches, as well as the contribution of SEA for sustainability in these territories. To achieve the research aim, exploratory research using a questionnaire-based survey was designed, aimed at experts on SEA in European small islands. Findings showed regional cooperation networks may have a fundamental role when developing SEA-specific approaches in these territories. This is because SEA-specific approaches encourage a joint effort among islands within one region to improve SEA capacity-building, develop and share a baseline information system, and to share and exchange resources, overall. Also, guidelines are preferred among experts over more legal frameworks and regulations. Finally, the research showed that experts view SEA as a way to enhance sustainability in small islands. This study highlights the importance of integrating

  8. Effect of field view size and lighting on unique-hue selection using Natural Color System object colors.

    Science.gov (United States)

    Shamey, Renzo; Zubair, Muhammad; Cheema, Hammad

    2015-08-01

    The aim of this study was twofold, first to determine the effect of field view size and second of illumination conditions on the selection of unique hue samples (UHs: R, Y, G and B) from two rotatable trays, each containing forty highly chromatic Natural Color System (NCS) samples, on one tray corresponding to 1.4° and on the other to 5.7° field of view size. UH selections were made by 25 color-normal observers who repeated assessments three times with a gap of at least 24h between trials. Observers separately assessed UHs under four illumination conditions simulating illuminants D65, A, F2 and F11. An apparent hue shift (statistically significant for UR) was noted for UH selections at 5.7° field of view compared to those at 1.4°. Observers' overall variability was found to be higher for UH stimuli selections at the larger field of view. Intra-observer variability was found to be approximately 18.7% of inter-observer variability in selection of samples for both sample sizes. The highest intra-observer variability was under simulated illuminant D65, followed by A, F11, and F2. Copyright © 2015 Elsevier Ltd. All rights reserved.

  9. Automation and remote access of EMBL small angle X-ray scattering beamline X33 dedicated to biological macromolecules

    International Nuclear Information System (INIS)

    Weifeng Shang; Roessle, M.; Blanchet, C.; Zozulya, A.; Franke, D.; Petoukhov, M.; Kikhney, A.; Svergun, D.

    2009-01-01

    Full text: The small-angle X-ray scattering beamline X33 of the European Molecular Biology Laboratory (EMBL) at the DORIS III storage ring (HASYLAB/DESY) has been dedicated to structural studies of non-crystalline biological systems for more than two decades. In the last several years, the introduction of new optical systems (monochromator, mirror, slits etc) and detector systems (large area image plate Mar345 and PILATUS 1M) leads to an improvement of photon flux by a factor of 3 and a reduction of the exposure time by a factor of 7. Moreover, an automated sample changer has been constructed and in operation since August 2007. The data analysis pipeline consisting of the program suite yields the radius of gyration and forward scattering intensity using Guinier analysis (AutoRg), pair distance distribution function p(r) using indirect Fourier transform method (AutoGNOM), and bead models using ab initio shape determination (DAMMIN and DAMMIF). The results of these analysis which are immediately available after each measurement provides an invaluable tool for data quality control during the data collection. Furthermore, works on remote control of the integrated data collection and analysis software is ongoing and expected to be operated in late 2009 where users can send their samples and control the measurements at home institutes. (author)

  10. Can They See It? The Functional Field of View Is Narrower in Individuals with Autism Spectrum Disorder.

    Science.gov (United States)

    Song, Yongning; Hakoda, Yuji; Sanefuji, Wakako; Cheng, Chen

    2015-01-01

    Although social cognitive deficits have long been thought to underlie the characteristic and pervasive difficulties with social interaction observed in individuals with autism spectrum disorder (ASD), several recent behavioral and neuroimaging studies have indicated that visual perceptual impairments might also play a role. People with ASD show a robust bias towards detailed information at the expense of global information, although the mechanisms that underlie this phenomenon remain elusive. To address this issue, we investigated the functional field of view in a group of high-functioning children with autism (n = 13) and a paired non-ASD group (n = 13). Our results indicate that the ability to correctly detect and identify stimuli sharply decreases with greater eccentricity from the fovea in people with ASD. Accordingly, a probe analysis revealed that the functional field of view in the ASD group was only about 6.62° of retinal eccentricity, compared with 8.57° in typically developing children. Thus, children with ASD appear to have a narrower functional field of view. These results challenge the conventional hypothesis that the deficit in global processing in individuals with ASD is solely due to weak central coherence. Alternatively, our data suggest that a narrower functional field of view may also contribute to this bias.

  11. Can They See It? The Functional Field of View Is Narrower in Individuals with Autism Spectrum Disorder.

    Directory of Open Access Journals (Sweden)

    Yongning Song

    Full Text Available Although social cognitive deficits have long been thought to underlie the characteristic and pervasive difficulties with social interaction observed in individuals with autism spectrum disorder (ASD, several recent behavioral and neuroimaging studies have indicated that visual perceptual impairments might also play a role. People with ASD show a robust bias towards detailed information at the expense of global information, although the mechanisms that underlie this phenomenon remain elusive. To address this issue, we investigated the functional field of view in a group of high-functioning children with autism (n = 13 and a paired non-ASD group (n = 13. Our results indicate that the ability to correctly detect and identify stimuli sharply decreases with greater eccentricity from the fovea in people with ASD. Accordingly, a probe analysis revealed that the functional field of view in the ASD group was only about 6.62° of retinal eccentricity, compared with 8.57° in typically developing children. Thus, children with ASD appear to have a narrower functional field of view. These results challenge the conventional hypothesis that the deficit in global processing in individuals with ASD is solely due to weak central coherence. Alternatively, our data suggest that a narrower functional field of view may also contribute to this bias.

  12. Progress on dedicated animal PET

    International Nuclear Information System (INIS)

    Liu Wei

    2002-01-01

    Positron emission tomography, as the leading technology providing molecular imaging of biological processes, is widely used on living laboratory animals. High-resolution dedicated animal PET scanners have been developed. Although the dedicated animal PET faces obstacles and challenges, this advanced technology would play an important role in molecular biomedicine researches, such as diseases study, medicine development, and gene therapy

  13. For a few dollars more: Public trust and the case for transporting nuclear waste in dedicated trains

    International Nuclear Information System (INIS)

    Glickman, T.S.; Golding, D.

    1991-01-01

    The debate about the use of dedicated trains for shipping spent fuel and high-level nuclear waste has been going on for the past l5 years. The nuclear industry and its regulatory agencies would like to consider the case closed. The recent passage of the Hazardous Materials Transportation Uniform Act of 1990, however, opens the door once more, giving the railroads and other proponents of dedicated trains another chance to present their case. This paper argues that earlier conclusions favoring regular trains over dedicated trains were based on incomplete cost and risk information and neglected other factors which are not technical, but social and institutional in nature. The paper finds that the additional cost of a dedicated system is lower than previously thought and concludes that it is a small price to pay for reduced public opposition and increased levels of trust

  14. Small-animal dark-field radiography for pulmonary emphysema evaluation

    Science.gov (United States)

    Yaroshenko, Andre; Meinel, Felix G.; Hellbach, Katharina; Bech, Martin; Velroyen, Astrid; Müller, Mark; Bamberg, Fabian; Nikolaou, Konstantin; Reiser, Maximilian F.; Yildirim, Ali Ã.-.; Eickelberg, Oliver; Pfeiffer, Franz

    2014-03-01

    Chronic obstructive pulmonary disease (COPD) is one of the leading causes of morbidity and mortality worldwide and emphysema is one of its main components. The disorder is characterized by irreversible destruction of the alveolar walls and enlargement of distal airspaces. Despite the severe changes in the lung tissue morphology, conventional chest radiographs have only a limited sensitivity for the detection of mild to moderate emphysema. X-ray dark-field is an imaging modality that can significantly increase the visibility of lung tissue on radiographic images. The dark-field signal is generated by coherent, small-angle scattering of x-rays on the air-tissue interfaces in the lung. Therefore, morphological changes in the lung can be clearly visualized on dark-field images. This is demonstrated by a preclinical study with a small-animal emphysema model. To generate a murine model of pulmonary emphysema, a female C57BL/6N mouse was treated with a single orotracheal application of porcine pancreatic elastase (80 U/kg body weight) dissolved in phosphate-buffered saline (PBS). Control mouse received PBS. The mice were imaged using a small-animal dark-field scanner. While conventional x-ray transmission radiography images revealed only subtle indirect signs of the pulmonary disorder, the difference between healthy and emphysematous lungs could be clearly directly visualized on the dark-field images. The dose applied to the animals is compatible with longitudinal studies. The imaging results correlate well with histology. The results of this study reveal the high potential of dark-field radiography for clinical lung imaging.

  15. Crustal concealing of small-scale core-field secular variation

    DEFF Research Database (Denmark)

    Hulot, G.; Olsen, Nils; Thebault, E.

    2009-01-01

    of internal origin happen to be detectable now in spherical harmonic degrees up to, perhaps, 16. All of these changes are usually attributed to changes in the core field itself, the secular variation, on the ground that the lithospheric magnetization cannot produce such signals. It has, however, been pointed...... out, on empirical grounds, that temporal changes in the field of internal origin produced by the induced part of the lithospheric magnetization could dominate the core field signal beyond degree 22. This short note revisits this issue by taking advantage of our improved knowledge of the small...... cause of the observed changes in the field of internal origin up to some critical degree, N-C, is indeed likely to be the secular variation of the core field, but that the signal produced by the time-varying lithospheric field is bound to dominate and conceal the time-varying core signal beyond...

  16. Energy Efficiency in Small Server Rooms: Field Surveys and Findings

    Energy Technology Data Exchange (ETDEWEB)

    Cheung, Iris [Hoi; Greenberg, Steve; Mahdavi, Roozbeh; Brown, Richard; Tschudi, William

    2014-08-11

    Fifty-seven percent of US servers are housed in server closets, server rooms, and localized data centers, in what are commonly referred to as small server rooms, which comprise 99percent of all server spaces in the US. While many mid-tier and enterprise-class data centers are owned by large corporations that consider energy efficiency a goal to minimize business operating costs, small server rooms typically are not similarly motivated. They are characterized by decentralized ownership and management and come in many configurations, which creates a unique set of efficiency challenges. To develop energy efficiency strategies for these spaces, we surveyed 30 small server rooms across eight institutions, and selected four of them for detailed assessments. The four rooms had Power Usage Effectiveness (PUE) values ranging from 1.5 to 2.1. Energy saving opportunities ranged from no- to low-cost measures such as raising cooling set points and better airflow management, to more involved but cost-effective measures including server consolidation and virtualization, and dedicated cooling with economizers. We found that inefficiencies mainly resulted from organizational rather than technical issues. Because of the inherent space and resource limitations, the most effective measure is to operate servers through energy-efficient cloud-based services or well-managed larger data centers, rather than server rooms. Backup power requirement, and IT and cooling efficiency should be evaluated to minimize energy waste in the server space. Utility programs are instrumental in raising awareness and spreading technical knowledge on server operation, and the implementation of energy efficiency measures in small server rooms.

  17. Rapid parameterization of small molecules using the Force Field Toolkit.

    Science.gov (United States)

    Mayne, Christopher G; Saam, Jan; Schulten, Klaus; Tajkhorshid, Emad; Gumbart, James C

    2013-12-15

    The inability to rapidly generate accurate and robust parameters for novel chemical matter continues to severely limit the application of molecular dynamics simulations to many biological systems of interest, especially in fields such as drug discovery. Although the release of generalized versions of common classical force fields, for example, General Amber Force Field and CHARMM General Force Field, have posited guidelines for parameterization of small molecules, many technical challenges remain that have hampered their wide-scale extension. The Force Field Toolkit (ffTK), described herein, minimizes common barriers to ligand parameterization through algorithm and method development, automation of tedious and error-prone tasks, and graphical user interface design. Distributed as a VMD plugin, ffTK facilitates the traversal of a clear and organized workflow resulting in a complete set of CHARMM-compatible parameters. A variety of tools are provided to generate quantum mechanical target data, setup multidimensional optimization routines, and analyze parameter performance. Parameters developed for a small test set of molecules using ffTK were comparable to existing CGenFF parameters in their ability to reproduce experimentally measured values for pure-solvent properties (<15% error from experiment) and free energy of solvation (±0.5 kcal/mol from experiment). Copyright © 2013 Wiley Periodicals, Inc.

  18. MO-D-BRD-02: In Memoriam of Bengt Bjarngard: SBRT II: Small Field Dosimetry - TG155

    International Nuclear Information System (INIS)

    Das, I; Reft, C

    2014-01-01

    Specialized radiation treatment such as SRS/SRT. SBRT, IMRT, VMAT, Tomotherapy, CyberKnife and Gamma Knife use small fields or combination of small fields where dosimetry is challenging and uncertain due to non-equilibrium conditions such as longitudinal and lateral disequilibrium. Additionally the primary photon fluence is greatly affected by the obstruction of the source size by the jaws creating a large dose gradient across the field. Electronic equilibrium is a phenomenon associated with the range of secondary particles which depend on the beam energy, photon spectrum and the composition of the medium. Additionally, the finite size of detectors creates volume averaging and fluence perturbations especially in small fields. The IAEA/AAPM has provided a frame work for non-compliant reference dosimetry in small fields1. The AAPM TG-1552 has adopted this frame work to provide guidelines in relative dosimetry. This course provides the insight of TG-155 that defines small field, provides recommendations for suitable detectors and associated correction factors to convert reading to dose. Recommendations of a good working practice for relative dosimetry measurements (PDD, TMR, output factor, etc.) and dose calculations based on the new formulation is are elaborated. It also discusses beam modeling and dose calculations as a critical step in clinical utilization of small field radiotherapy. Small errors in beam data, approximations in dose algorithms, or misaligned of detectors and field settings can propagate into large errors in planned and delivered dose. The modeling and treatment planning aspects of small field dosimetry are reviewed with emphasis on the most critical parts for ensuring accurate and safe radiation therapy. Discussion on k(fmsr, fclin) for commercially available detectors are also provided.1 P. Alfonso, P. Andreo, R. Capote, M. S. Huq, W. Kilby, P. Kjall, T. R. Mackie, H. Palmans, K. Rosser, J. Seuntjens, W. Ullrich and S. Vatnitsky, “A new

  19. Inferring spatial clouds statistics from limited field-of-view, zenith observations

    Energy Technology Data Exchange (ETDEWEB)

    Sun, C.H.; Thorne, L.R. [Sandia National Labs., Livermore, CA (United States)

    1996-04-01

    Many of the Cloud and Radiation Testbed (CART) measurements produce a time series of zenith observations, but spatial averages are often the desired data product. One possible approach to deriving spatial averages from temporal averages is to invoke Taylor`s hypothesis where and when it is valid. Taylor`s hypothesis states that when the turbulence is small compared with the mean flow, the covariance in time is related to the covariance in space by the speed of the mean flow. For clouds fields, Taylor`s hypothesis would apply when the {open_quotes}local{close_quotes} turbulence is small compared with advective flow (mean wind). The objective of this study is to determine under what conditions Taylor`s hypothesis holds or does not hold true for broken cloud fields.

  20. High speed color imaging through scattering media with a large field of view

    Science.gov (United States)

    Zhuang, Huichang; He, Hexiang; Xie, Xiangsheng; Zhou, Jianying

    2016-09-01

    Optical imaging through complex media has many important applications. Although research progresses have been made to recover optical image through various turbid media, the widespread application of the technology is hampered by the recovery speed, requirement on specific illumination, poor image quality and limited field of view. Here we demonstrate that above-mentioned drawbacks can be essentially overcome. The realization of high speed color imaging through turbid media is successfully carried out by taking into account the media memory effect, the point spread function, the exit pupil of the optical system, and the optimized signal to noise ratio. By retrieving selected speckles with enlarged field of view, high quality image is recovered with a responding speed only determined by the frame rates of the image capturing devices. The immediate application of the technique is expected to register static and dynamic imaging under human skin to recover information with a wearable device.

  1. American Views of the Cultural Imperialism Charge.

    Science.gov (United States)

    Breen, Myles P.

    The United States is a major exporter but a minor importer of films and television programs; this situation has been described as a one-way flow of information from the United States to other nations. Although the official United States position is one of dedication to the two-way flow of communication, the "majority" view is that the…

  2. [Major influential factors of the micturition alert device dedicated to neurogenic bladders].

    Science.gov (United States)

    Wang, Jianhuo; Hou, Chunlin; Zheng, Xianyou; Xu, Zhen; Wang, Wanhong; Lin, Haodong

    2008-08-01

    To study major influential factors of the micturition alert device dedicated to neurogenic bladders for the product design and clinical application of the device. One ferrite permanent magnet with thickness and diameter of 3 mm and 10 mm, respectively, and three NdFeB permanent magnets with the thickness of 3 mm and diameter of 10, 15 and 20 mm, respectively, were used. The effects of thickness of the abdominal wall as well as the position and type of permanent magnets on the micturition alert device dedicated to neurogenic bladders were measured in vitro simulated test, when the abdominal wall was set to 2, 3, 4, 5, 6, 7, 8 and 9 cm, respectively, and the position of permanent magnets was 0, 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11 and 12 cm, respectively. The effect of the geomagnetic field on the device was measured under the condition that the thickness of the simulated abdominal wall was set to 2, 3, 4 and 5 cm, respectively, and the position of permanent magnets was 2, 3, 4, 5, 6, 7, 8, 9 and 10 cm, respectively. The value showed in the warning unit was positively correlated with the position of the ferrite permanent magnet only when the thickness of the simulated abdominal wall was 2 cm (r=0.632, P NdFeB permanent magnets was significant (r > 0.622, P NdFeB permanent magnets, but weakened with the increasing thickness of the simulated abdominal wall. The effect of the geomagnetic field was correlated with the exposition of the body, the position of the permanent magnet and the thickness of the abdominal wall. The major influential factors of the micturition alert device dedicated to neurogenic bladder include the magnetism and location of the permanent magnet, the thickness of the abdominal wall and the geomagnetic field. These factors are correlated with and affect each other. Reasonable allocation of these factors may optimize the device.

  3. Visual search for features and conjunctions following declines in the useful field of view.

    Science.gov (United States)

    Cosman, Joshua D; Lees, Monica N; Lee, John D; Rizzo, Matthew; Vecera, Shaun P

    2012-01-01

    BACKGROUND/STUDY CONTEXT: Typical measures for assessing the useful field (UFOV) of view involve many components of attention. The objective of the current experiment was to examine differences in visual search efficiency for older individuals with and without UFOV impairment. The authors used a computerized screening instrument to assess the useful field of view and to characterize participants as having an impaired or normal UFOV. Participants also performed two visual search tasks, a feature search (e.g., search for a green target among red distractors) or a conjunction search (e.g., a green target with a gap on its left or right side among red distractors with gaps on the left or right and green distractors with gaps on the top or bottom). Visual search performance did not differ between UFOV impaired and unimpaired individuals when searching for a basic feature. However, search efficiency was lower for impaired individuals than unimpaired individuals when searching for a conjunction of features. The results suggest that UFOV decline in normal aging is associated with conjunction search. This finding suggests that the underlying cause of UFOV decline may arise from an overall decline in attentional efficiency. Because the useful field of view is a reliable predictor of driving safety, the results suggest that decline in the everyday visual behavior of older adults might arise from attentional declines.

  4. Facilities for small-molecule crystallography at synchrotron sources.

    Science.gov (United States)

    Barnett, Sarah A; Nowell, Harriott; Warren, Mark R; Wilcox, Andrian; Allan, David R

    2016-01-01

    Although macromolecular crystallography is a widely supported technique at synchrotron radiation facilities throughout the world, there are, in comparison, only very few beamlines dedicated to small-molecule crystallography. This limited provision is despite the increasing demand for beamtime from the chemical crystallography community and the ever greater overlap between systems that can be classed as either small macromolecules or large small molecules. In this article, a very brief overview of beamlines that support small-molecule single-crystal diffraction techniques will be given along with a more detailed description of beamline I19, a dedicated facility for small-molecule crystallography at Diamond Light Source.

  5. Inhomogeneous initial data and small-field inflation

    Science.gov (United States)

    Marsh, M. C. David; Barrow, John D.; Ganguly, Chandrima

    2018-05-01

    We consider the robustness of small-field inflation in the presence of scalar field inhomogeneities. Previous numerical work has shown that if the scalar potential is flat only over a narrow interval, such as in commonly considered inflection-point models, even small-amplitude inhomogeneities present at the would-be onset of inflation at τ = τi can disrupt the accelerated expansion. In this paper, we parametrise and evolve the inhomogeneities from an earlier time τIC at which the initial data were imprinted, and show that for a broad range of inflationary and pre-inflationary models, inflection-point inflation withstands initial inhomogeneities. We consider three classes of perturbative pre-inflationary solutions (corresponding to energetic domination by the scalar field kinetic term, a relativistic fluid, and isotropic negative curvature), and two classes of exact solutions to Einstein's equations with large inhomogeneities (corresponding to a stiff fluid with cylindrical symmetry, and anisotropic negative curvature). We derive a stability condition that depends on the Hubble scales H(τi) and H(τIC), and a few properties of the pre-inflationary cosmology. For initial data imprinted at the Planck scale, the absence of an inhomogeneous initial data problem for inflection-point inflation leads to a novel, lower limit on the tensor-to-scalar ratio.

  6. High resolution SPECT imaging for visualization of intratumoral heterogeneity using a SPECT/CT scanner dedicated for small animal imaging

    International Nuclear Information System (INIS)

    Umeda, Izumi O.; Tani, Kotaro; Tsuda, Keisuke

    2012-01-01

    Tumor interiors are never homogeneous and in vivo visualization of intratumoral heterogeneity would be an innovation that contributes to improved cancer therapy. But, conventional nuclear medicine tests have failed to visualize heterogeneity in vivo because of limited spatial resolution. Recently developed single photon emission computed tomographic (SPECT) scanners dedicated for small animal imaging are of interest due to their excellent spatial resolution of 111 In and simulations of actual small animal imaging. The optimal conditions obtained were validated by in vivo imaging of sarcoma 180-bearing mice. Larger number of counts must be obtained within limited acquisition time to visualize tumor heterogeneity in vivo in animal imaging, compared to cases that simply detect tumors. At an acquisition time of 30 min, better image quality was obtained with pinhole apertures diameter of 1.4 mm than of 1.0 mm. The obtained best spatial resolution was 1.3 mm, it was acceptable for our purpose, though a little worse than the best possible performance of the scanner (1.0 mm). Additionally, the reconstruction parameters, such as noise suppression, voxel size, and iteration/subset number, needed to be optimized under the limited conditions and were different from those found under the ideal condition. The minimal radioactivity concentration for visualization of heterogeneous tumor interiors was estimated to be as high as 0.2-0.5 MBq/mL. Liposomes containing 111 In met this requirement and were administered to tumor-bearing mice. SPECT imaging successfully showed heterogeneous 111 In distribution within the tumors in vivo with good spatial resolution. A threshold of 0.2 MBq/g for clear visualization of tumor heterogeneity was validated. Autoradiograms obtained ex vivo of excised tumors confirmed that the in vivo SPECT images accurately depicted the heterogeneous intratumoral accumulation of liposomes. Intratumoral heterogeneity was successfully visualized under the optimized

  7. A modified method of calculating the lateral build-up ratio for small electron fields

    International Nuclear Information System (INIS)

    Tyner, E; McCavana, P; McClean, B

    2006-01-01

    This note outlines an improved method of calculating dose per monitor unit values for small electron fields using Khan's lateral build-up ratio (LBR). This modified method obtains the LBR directly from the ratio of measured, surface normalized, electron beam percentage depth dose curves. The LBR calculated using this modified method more accurately accounts for the change in lateral scatter with decreasing field size. The LBR is used along with Khan's dose per monitor unit formula to calculate dose per monitor unit values for a set of small fields. These calculated dose per monitor unit values are compared to measured values to within 3.5% for all circular fields and electron energies examined. The modified method was further tested using a small triangular field. A maximum difference of 4.8% was found. (note)

  8. Astronomical Orientation Method Based on Lunar Observations Utilizing Super Wide Field of View

    Directory of Open Access Journals (Sweden)

    PU Junyu

    2018-04-01

    Full Text Available In this paper,astronomical orientation is achieved by observing the moon utilizing camera with super wide field of view,and formulae are deduced in detail.An experiment based on real observations verified the stability of the method.In this experiment,after 15 minutes' tracking shoots,the internal precision could be superior to ±7.5" and the external precision could approximately reach ±20".This camera-based method for astronomical orientation can change the traditional mode (aiming by human eye based on theodolite,thus lowering the requirements for operator's skill to some extent.Furthermore,camera with super wide field of view can realize the function of continuous tracking shoots on the moon without complicated servo control devices.Considering the similar existence of gravity on the moon and the earth's phase change when observed from the moon,once the technology of self-leveling is developed,this method can be extended to orientation for lunar rover by shooting the earth.

  9. Multiplexing and de-multiplexing with scattering media for large field of view and multispectral imaging

    Science.gov (United States)

    Sahoo, Sujit Kumar; Tang, Dongliang; Dang, Cuong

    2018-02-01

    Large field of view multispectral imaging through scattering medium is a fundamental quest in optics community. It has gained special attention from researchers in recent years for its wide range of potential applications. However, the main bottlenecks of the current imaging systems are the requirements on specific illumination, poor image quality and limited field of view. In this work, we demonstrated a single-shot high-resolution colour-imaging through scattering media using a monochromatic camera. This novel imaging technique is enabled by the spatial, spectral decorrelation property and the optical memory effect of the scattering media. Moreover the use of deconvolution image processing further annihilate above-mentioned drawbacks arise due iterative refocusing, scanning or phase retrieval procedures.

  10. TH-EF-204-02: Small Field Radiation Therapy: Physics and Recent Recommendations From IAEA and ICRU

    International Nuclear Information System (INIS)

    Seuntjens, J.

    2016-01-01

    Joanna E. Cygler, Jan Seuntjens, J. Daniel Bourland, M. Saiful Huq, Josep Puxeu Vaque, Daniel Zucca Aparicio, Tatiana Krylova, Yuri Kirpichev, Eric Ford, Caridad Borras Stereotactic Radiation Therapy (SRT) utilizes small static and dynamic (IMRT) fields, to successfully treat malignant and benign diseases using techniques such as Stereotactic Radiosurgery (SRS) and Stereotactic Body Radiation Therapy (SBRT). SRT is characterized by sharp dose gradients for individual fields and their resultant dose distributions. For appropriate targets, small field radiotherapy offers improved treatment quality by allowing better sparing of organs at risk while delivering the prescribed target dose. Specialized small field treatment delivery systems, such as robotic-controlled linear accelerators, gamma radiosurgery units, and dynamic arc linear accelerators may utilize rigid fixation, image guidance, and tumor tracking, to insure precise dose delivery to static or moving targets. However, in addition to great advantages, small field delivery techniques present special technical challenges for dose calibration due to unique geometries and small field sizes not covered by existing reference dosimetry protocols such as AAPM TG-51 or IAEA TRS 398. In recent years extensive research has been performed to understand small field dosimetry and measurement instrumentation. AAPM, IAEA and ICRU task groups are expected to provide soon recommendations on the dosimetry of small radiation fields. In this symposium we will: 1] discuss the physics, instrumentation, methodologies and challenges for small field radiation dose measurements; 2] review IAEA and ICRU recommendations on prescribing, recording and reporting of small field radiation therapy; 3] discuss selected clinical applications and technical aspects for specialized image-guided, small field, linear accelerator based treatment techniques such as IMRT and SBRT. Learning Objectives: To learn the physics of small fields in contrast to

  11. TH-EF-204-02: Small Field Radiation Therapy: Physics and Recent Recommendations From IAEA and ICRU

    Energy Technology Data Exchange (ETDEWEB)

    Seuntjens, J. [McGill University (Canada)

    2016-06-15

    Joanna E. Cygler, Jan Seuntjens, J. Daniel Bourland, M. Saiful Huq, Josep Puxeu Vaque, Daniel Zucca Aparicio, Tatiana Krylova, Yuri Kirpichev, Eric Ford, Caridad Borras Stereotactic Radiation Therapy (SRT) utilizes small static and dynamic (IMRT) fields, to successfully treat malignant and benign diseases using techniques such as Stereotactic Radiosurgery (SRS) and Stereotactic Body Radiation Therapy (SBRT). SRT is characterized by sharp dose gradients for individual fields and their resultant dose distributions. For appropriate targets, small field radiotherapy offers improved treatment quality by allowing better sparing of organs at risk while delivering the prescribed target dose. Specialized small field treatment delivery systems, such as robotic-controlled linear accelerators, gamma radiosurgery units, and dynamic arc linear accelerators may utilize rigid fixation, image guidance, and tumor tracking, to insure precise dose delivery to static or moving targets. However, in addition to great advantages, small field delivery techniques present special technical challenges for dose calibration due to unique geometries and small field sizes not covered by existing reference dosimetry protocols such as AAPM TG-51 or IAEA TRS 398. In recent years extensive research has been performed to understand small field dosimetry and measurement instrumentation. AAPM, IAEA and ICRU task groups are expected to provide soon recommendations on the dosimetry of small radiation fields. In this symposium we will: 1] discuss the physics, instrumentation, methodologies and challenges for small field radiation dose measurements; 2] review IAEA and ICRU recommendations on prescribing, recording and reporting of small field radiation therapy; 3] discuss selected clinical applications and technical aspects for specialized image-guided, small field, linear accelerator based treatment techniques such as IMRT and SBRT. Learning Objectives: To learn the physics of small fields in contrast to

  12. Cosmic microwave background observables of small field models of inflation

    International Nuclear Information System (INIS)

    Ben-Dayan, Ido; Brustein, Ram

    2010-01-01

    We construct a class of single small field models of inflation that can predict, contrary to popular wisdom, an observable gravitational wave signal in the cosmic microwave background anisotropies. The spectral index, its running, the tensor to scalar ratio and the number of e-folds can cover all the parameter space currently allowed by cosmological observations. A unique feature of models in this class is their ability to predict a negative spectral index running in accordance with recent cosmic microwave background observations. We discuss the new class of models from an effective field theory perspective and show that if the dimensionless trilinear coupling is small, as required for consistency, then the observed spectral index running implies a high scale of inflation and hence an observable gravitational wave signal. All the models share a distinct prediction of higher power at smaller scales, making them easy targets for detection

  13. Small field axion inflation with sub-Planckian decay constant

    Energy Technology Data Exchange (ETDEWEB)

    Kadota, Kenji [Center for Theoretical Physics of the Universe, Institute for Basic Science,Daejeon 305-811 (Korea, Republic of); Kobayashi, Tatsuo [Department of Physics, Hokkaido University,Sapporo 060-0810 (Japan); Oikawa, Akane [Department of Physics, Waseda University,Tokyo 169-8555 (Japan); Omoto, Naoya [Department of Physics, Hokkaido University,Sapporo 060-0810 (Japan); Otsuka, Hajime [Department of Physics, Waseda University,Tokyo 169-8555 (Japan); Tatsuishi, Takuya H. [Department of Physics, Hokkaido University,Sapporo 060-0810 (Japan)

    2016-10-10

    We study an axion inflation model recently proposed within the framework of type IIB superstring theory, where we pay a particular attention to a sub-Planckian axion decay constant. Our axion potential can lead to the small field inflation with a small tensor-to-scalar ratio, and a typical reheating temperature can be as low as GeV.

  14. EMBRACE@Nançay: an ultra wide field of view prototype for the SKA

    International Nuclear Information System (INIS)

    Torchinsky, S.A.; Censier, B.; Serylak, M.; Renaud, P.; Taffoureau, C.; Olofsson, A.O.H.; Karastergiou, A.

    2015-01-01

    A revolution in radio receiving technology is underway with the development of densely packed phased arrays for radio astronomy. This technology can provide an exceptionally large field of view, while at the same time sampling the sky with high angular resolution. Such an instrument, with a field of view of over 100 square degrees, is ideal for performing fast, all-sky, surveys, such as the ''intensity mapping'' experiment to measure the signature of Baryonic Acoustic Oscillations in the HI mass distribution at cosmological redshifts. The SKA, built with this technology, will be able to do a billion galaxy survey. I will present a very brief introduction to radio interferometry, as well as an overview of the Square Kilometre Array project. This will be followed by a description of the EMBRACE prototype and a discussion of results and future plans

  15. SU-F-T-557: Evaluation of Detector Response in Rectangular Small Field Dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Qureshi, A [University of Toledo, Toledo, Ohio (United States); Tanny, S [SUNY Upstate Medical University, Syracuse NY (United States); Parsai, E; Sperling, N [University of Toledo Medical Center, Toledo, OH (United States)

    2016-06-15

    Purpose: As stereotactic treatment modalities grow towards becoming the standard of care, the need for accurate dose computation in small fields is becoming increasingly essential. The purpose of this study is to evaluate the response of different detectors, intended for small field dosimetry, in jaw defined small rectangular fields by analyzing output factors from a stereotactic clinical accelerator. Methods: Two Dosimeters, the Exradin A26 Microionization Chamber (Standard Imaging) and Edge Diode Detector (Sun Nuclear) were used to measure output factors taken on the Varian Edge Stereotactic Linear accelerator. Measurements were taken at 6MV and 6FFF at 10cm depth, 100cm SSD in a 48×48×40cm3 Welhoffer BluePhantom2 (IBA) with X and Y jaws set from 0.6 to 2.0cm. Output factors were normalized to a 5×5cm2 machine-specific reference field. Measurements were made in the vertical orientation for the A26 and horizontal orientation for both the A26 and Edge. Output factors were measured as: OF{sub FS} = M{sub FS}/M{sub ref} where M{sub FS} and M{sub ref} are the measured signals for the clinical field and the reference field, respectively. Measured output factors were then analyzed to establish relative responses of the detectors in small fields. Results: At 6MV the Edge detector exhibited a variation in output factors dependent on jaw positioning (X-by-Y vs Y-by-X) of 5.7% of the 5×5cm reference output and a variation of 3.33% at 6FFF. The A26 exhibited variation of output factor dependent on jaw positioning of upto 7.7% of the 5×5cm reference field at 6MV and upto 5.33% at 6FFF. Conclusion: Both the Edge detector and A26 responded as expected at small fields however a dependence on the jaw positioning was noted. At 6MV and 6FFF the detector response showed an increased dependence on the positioning of the X jaws as compared to the positioning of the Y jaws.

  16. Dynamic registration of an optical see-through HMD into a wide field-of-view rotorcraft flight simulation environment

    Science.gov (United States)

    Viertler, Franz; Hajek, Manfred

    2015-05-01

    To overcome the challenge of helicopter flight in degraded visual environments, current research considers headmounted displays with 3D-conformal (scene-linked) visual cues as most promising display technology. For pilot-in-theloop simulations with HMDs, a highly accurate registration of the augmented visual system is required. In rotorcraft flight simulators the outside visual cues are usually provided by a dome projection system, since a wide field-of-view (e.g. horizontally > 200° and vertically > 80°) is required, which can hardly be achieved with collimated viewing systems. But optical see-through HMDs do mostly not have an equivalent focus compared to the distance of the pilot's eye-point position to the curved screen, which is also dependant on head motion. Hence, a dynamic vergence correction has been implemented to avoid binocular disparity. In addition, the parallax error induced by even small translational head motions is corrected with a head-tracking system to be adjusted onto the projected screen. For this purpose, two options are presented. The correction can be achieved by rendering the view with yaw and pitch offset angles dependent on the deviating head position from the design eye-point of the spherical projection system. Furthermore, it can be solved by implementing a dynamic eye-point in the multi-channel projection system for the outside visual cues. Both options have been investigated for the integration of a binocular HMD into the Rotorcraft Simulation Environment (ROSIE) at the Technische Universitaet Muenchen. Pros and cons of both possibilities with regard on integration issues and usability in flight simulations will be discussed.

  17. Small field in-air output factors: The role of miniphantom design and dosimeter type

    International Nuclear Information System (INIS)

    Warrener, Kirbie; Hug, Benjamin; Ebert, Martin A.; Liu, Paul; McKenzie, David R.; Ralston, Anna; Suchowerska, Natalka

    2014-01-01

    Purpose: The commissioning of treatment planning systems and beam modeling requires measured input parameters. The measurement of relative output in-air, S c is particularly difficult for small fields. The purpose of this study was to investigate the influence of miniphantom design and detector selection on measured S c values for small fields and to validate the measurements against Monte Carlo simulations. Methods: Measurements were performed using brass caps (with sidewalls) or tops (no sidewalls) of varying heights and widths. The performance of two unshielded diodes (60012 and SFD), EBT2 radiochromic film, and a fiber optic dosimeter (FOD) were compared for fields defined by MLCs (5–100 mm) and SRS cones (4–30 mm) on a Varian Novalis linear accelerator. Monte Carlo simulations were performed to theoretically predict S c as measured by the FOD. Results: For all detectors, S c agreed to within 1% for fields larger than 10 mm and to within 2.3% for smaller fields. Monte Carlo simulation matched the FOD measurements for all size of cone defined fields to within 0.5%. Conclusions: Miniphantom design is the most important variable for reproducible and accurate measurements of the in-air output ratio, S c , in small photon fields (less than 30 mm). Sidewalls are not required for fields ≤ 30 mm and tops are therefore preferred over the larger caps. Unlike output measurements in water, S cp, the selection of detector type for S c is not critical, provided the active dosimeter volume is small relative to the field size

  18. Modality comparison for small animal radiotherapy: A simulation study

    Energy Technology Data Exchange (ETDEWEB)

    Bazalova, Magdalena, E-mail: bazalova@stanford.edu; Nelson, Geoff; Noll, John M.; Graves, Edward E. [Department of Radiation Oncology, Molecular Imaging Program at Stanford, Stanford University, Stanford, California 94305 (United States)

    2014-01-15

    Purpose: Small animal radiation therapy has advanced significantly in recent years. Whereas in the past dose was delivered using a single beam and a lead shield for sparing of healthy tissue, conformal doses can be now delivered using more complex dedicated small animal radiotherapy systems with image guidance. The goal of this paper is to investigate dose distributions for three small animal radiation treatment modalities. Methods: This paper presents a comparison of dose distributions generated by the three approaches—a single-field irradiator with a 200 kV beam and no image guidance, a small animal image-guided conformal system based on a modified microCT scanner with a 120 kV beam developed at Stanford University, and a dedicated conformal system, SARRP, using a 220 kV beam developed at Johns Hopkins University. The authors present a comparison of treatment plans for the three modalities using two cases: a mouse with a subcutaneous tumor and a mouse with a spontaneous lung tumor. A 5 Gy target dose was calculated using the EGSnrc Monte Carlo codes. Results: All treatment modalities generated similar dose distributions for the subcutaneous tumor case, with the highest mean dose to the ipsilateral lung and bones in the single-field plan (0.4 and 0.4 Gy) compared to the microCT (0.1 and 0.2 Gy) and SARRP (0.1 and 0.3 Gy) plans. The lung case demonstrated that due to the nine-beam arrangements in the conformal plans, the mean doses to the ipsilateral lung, spinal cord, and bones were significantly lower in the microCT plan (2.0, 0.4, and 1.9 Gy) and the SARRP plan (1.5, 0.5, and 1.8 Gy) than in single-field irradiator plan (4.5, 3.8, and 3.3 Gy). Similarly, the mean doses to the contralateral lung and the heart were lowest in the microCT plan (1.5 and 2.0 Gy), followed by the SARRP plan (1.7 and 2.2 Gy), and they were highest in the single-field plan (2.5 and 2.4 Gy). For both cases, dose uniformity was greatest in the single-field irradiator plan followed by

  19. Use of a microprocessor in the CAMAC standard. The dedicated microcomputer: JCAM-10

    International Nuclear Information System (INIS)

    Gallice, Pierre.

    1978-01-01

    The general purpose minicomputers and dedicated crate controllers currently used in small CAMAC systems are now being superseded by autonomous crate controllers with built-in microprocessor such as the JCAM-10, which is in fact a CAMAC dedicated microcomputer. This controller has been designed around the INTEL-8080 microprocessor and employs a semiconductor memory. The very much reduced price and smaller packaging of this module, and the relatively large potential market of CAMAC systems justify the tremendous efforts required for the study of its complete system as well in hardware than in software. After a short description of the CAMAC standard this paper will describe the principle of the microcomputer JCAM-10, and its complementary system: hardware (peripheral modules) and software (TTY command processor, Input Output, Control system, interrupt system, text editor, local macro-assembler, LP and BASICAM local compilers). As application examples, an autonomous counting system and a distributed intelligence system will be described [fr

  20. Outcomes of patients presenting to a dedicated rapid access lung cancer clinic.

    LENUS (Irish Health Repository)

    Dunican, E

    2012-02-01

    We examined the outcomes of the first 500 patients referred to a dedicated Rapid Access Lung Cancer Clinic. A total of 206 patients (41.2%) were diagnosed with a thoracic malignancy; 179 had primary lung cancer and 27 had secondary or other thoracic cancers. Pulmonary nodules requiring ongoing surveillance were found in a further 79 patients (15.8%). Of those patients found to have primary lung cancer, 24 (13.4%) had Small Cell and 145 (81%) had Non Small Cell Lung Cancer. In patients with Non small cell tumours, 26 (21.1%) were stage 1, 14 (11.4%) stage II, 37 (30.1%) stage III and 46 (37.4%) stage IV at diagnosis. For the 129 patients (72%) in whom the thoracic MDT recommended active treatment, primary therapy was surgical resection in 44 (24.6%), combined chemoradiation in 31 patients (17.3%), chemotherapy alone in 39 (21.8%) and radiation in 15 (8.4%).

  1. Development of dedicated nuclear heating plants in the Federal Republic of Germany

    International Nuclear Information System (INIS)

    Goetzmann, C.A.; Schroeter, K.E.

    1987-01-01

    In many cases district heating is both economically and environmentally superior over directly burning of fossil fuels in individual furnaces primarily because of the efficiency of the usual applied co-generation principle with regard to fuel utilization and flue gas clean up. In principle, this argument should carry even greater weight in conjunction with nuclear energy. The major draw back of dedicated heating reactors as seen up to now concerns the high specific capital cost for the application-dictated small reactor size. The paper discusses by way of a specific example in what directions solutions are being sought. (author)

  2. Development of dedicated nuclear heating plants in the Federal Republic of Germany

    International Nuclear Information System (INIS)

    Goetzmann, C.A.; Schroeter, K.E.

    1988-01-01

    In many cases district heating is both economically and environmentally superior over directly burning of fossil fuels in individual furnaces primarily because of the efficiency of the usual applied co-generation principle with regard to fuel utilization and flue gas clean up. In principle, this argument should carry even greater weight in conjunction with nuclear energy. The major draw back of dedicated heating reactors as seen up to now concerns the high specific capital cost for the application-dictated small reactor size. The paper discusses by way of a specific example in what directions solutions are being sought

  3. Use of commercial grade item dedication to reduce procurement costs

    International Nuclear Information System (INIS)

    Rosch, F.

    1995-01-01

    In the mid-1980s, the Nuclear Regulatory Industry (NRC) began inspecting utility practices of procuring and dedicating commercial grade items intended for plant safety-related applications. As a result of the industry efforts to address NRC concerns, nuclear utilities have enhanced existing programs and procedures for dedication of commercial grade items. Though these programs were originally enhanced to meet NRC concerns, utilities have discovered that the dedication of commercial grade items can also reduce overall procurement costs. This paper will discuss the enhancement of utility dedication programs and demonstrates how utilities have utilized them to reduce procurement costs

  4. The marketing strategy of a small enterprise

    OpenAIRE

    Trandafilović Igor

    2008-01-01

    Small enterprise shows some specific characteristics which are necessary for creation of marketing strategy. The goal of this work is an attempt of marketing strategy analysis of the small enterprises. The necessary request of the analysis is to define the small enterprise. There have also been analyzed the specific orders for small enterpriser. Special part of work is dedicated to a small enterprises management strategy and the other one to their marketing communications. There are mentioned...

  5. A Dedicated Genetic Algorithm for Localization of Moving Magnetic Objects

    Directory of Open Access Journals (Sweden)

    Roger Alimi

    2015-09-01

    Full Text Available A dedicated Genetic Algorithm (GA has been developed to localize the trajectory of ferromagnetic moving objects within a bounded perimeter. Localization of moving ferromagnetic objects is an important tool because it can be employed in situations when the object is obscured. This work is innovative for two main reasons: first, the GA has been tuned to provide an accurate and fast solution to the inverse magnetic field equations problem. Second, the algorithm has been successfully tested using real-life experimental data. Very accurate trajectory localization estimations were obtained over a wide range of scenarios.

  6. SU-E-T-323: Dosimetric Evaluation of Small Fields for SBRT Treatment

    Energy Technology Data Exchange (ETDEWEB)

    Gupta, R; Eldib, A; Wang, B; Ma, C; Li, J [Fox Chase Cancer Center, Philadelphia, PA (United States)

    2015-06-15

    Purpose: Stereotactic body radiation therapy (SBRT) is commonly employed to treat small targets for effective tumor control with radiation beams of small field sizes. The goal of this work was to evaluate dosimetrically a treatment planning system (TPS) by comparing the calculated dose for SBRT treatment with ion-chamber measurements. Methods: 3D images of a solid-water phantom with a pinpoint ion-chamber (0.015cm3) inside were acquired with a CT scanner. Active volume of the ion-chamber was delineated on CT images. Targets with a diameter of 1.5cm, 2cm, 3cm, 4cm and 5cm were drawn around the chamber. 3DCRT plans were generated for each target size with centrally opened 6MV beams and off-axis beams by changing the isocenter location, respectively, using a TPS with the Analytical Anisotropic Algorithm. A 21iX linear accelerator was employed for plan delivery. The measured and calculated doses were compared. To evaluate the dose calculations in heterogeneity for small fields SBRT treatment, similar plans were also generated and delivered on a heterogeneous thoracic phantom for 5 different size targets in the lung. Results: Dose comparisons between measurements and calculations showed 5.2%, 1.88%, 1.34%, 1.01% and 0.85% difference for SBRT plans with small central axis beams and 0.96%, 0.15%, 0.58%, 0.22% and 0.77% difference for plans with off-axis beams for five different size targets. For the thoracic phantom, the differences on dose between measurements and calculations are bigger, which are 8%, 5.9%, 4.5%, 3.9% and 4.5%, respectively. Conclusion: Dose verification for small fields used in the SBRT treatment has been performed based on ion-chamber measurements in both homogenous and heterogeneous phantoms. More than a 5% difference has been observed in the heterogeneous phantom, especially for very small fields. To meet the ICRU recommendation on a dose difference of no more than 5%, some corrections on the commissioning parameters of the TPS are needed.

  7. Restricting the vertical and horizontal extent of the Field-of-View: Effects on manoeuvring performance

    NARCIS (Netherlands)

    Jansen, S.E.M.; Toet, A.; Delleman, N.J.

    2010-01-01

    It is known that Field-of-view restrictions affect distance estimation, postural equilibrium, and the ability to control heading. These are all important factors when manoeuvring on foot through complex structured environments. Although considerable research has been devoted to the horizontal

  8. Small field in-air output factors: The role of miniphantom design and dosimeter type

    Energy Technology Data Exchange (ETDEWEB)

    Warrener, Kirbie, E-mail: kirbie.warrener@sesiahs.health.nsw.gov.au [Illawarra Cancer Care Centre, Wollongong Hospital, Wollongong, New South Wales 2521, Australia and Centre for Medical Radiation Physics, University of Wollongong, Wollongong, New South Wales 2522 (Australia); Hug, Benjamin; Ebert, Martin A. [School of Physics, University of Western Australia, Crawley, Western Australia 6009, Australia and Department of Radiation Oncology, Sir Charles Gairdner Hospital, Perth, Western Australia 6009 (Australia); Liu, Paul; McKenzie, David R. [School of Physics, University of Sydney, Darlington, New South Wales 2008 (Australia); Ralston, Anna [Chris O' Brien Lifehouse, Radiation Oncology, Sydney, New South Wales 2050 (Australia); Suchowerska, Natalka [School of Physics, University of Sydney, Darlington, New South Wales 2008, Australia and Chris O' Brien Lifehouse, Radiation Oncology, Sydney, New South Wales 2050 (Australia)

    2014-02-15

    Purpose: The commissioning of treatment planning systems and beam modeling requires measured input parameters. The measurement of relative output in-air, S{sub c} is particularly difficult for small fields. The purpose of this study was to investigate the influence of miniphantom design and detector selection on measured S{sub c} values for small fields and to validate the measurements against Monte Carlo simulations. Methods: Measurements were performed using brass caps (with sidewalls) or tops (no sidewalls) of varying heights and widths. The performance of two unshielded diodes (60012 and SFD), EBT2 radiochromic film, and a fiber optic dosimeter (FOD) were compared for fields defined by MLCs (5–100 mm) and SRS cones (4–30 mm) on a Varian Novalis linear accelerator. Monte Carlo simulations were performed to theoretically predict S{sub c} as measured by the FOD. Results: For all detectors, S{sub c} agreed to within 1% for fields larger than 10 mm and to within 2.3% for smaller fields. Monte Carlo simulation matched the FOD measurements for all size of cone defined fields to within 0.5%. Conclusions: Miniphantom design is the most important variable for reproducible and accurate measurements of the in-air output ratio, S{sub c}, in small photon fields (less than 30 mm). Sidewalls are not required for fields ≤ 30 mm and tops are therefore preferred over the larger caps. Unlike output measurements in water, S{sub cp,} the selection of detector type for S{sub c} is not critical, provided the active dosimeter volume is small relative to the field size.

  9. Berlin Electron Storage Ring BESSY: a dedicated XUV synchrotron radiation facility

    International Nuclear Information System (INIS)

    Muelhaupt, G.; Bradshaw, A.M.

    1985-01-01

    In response to national requirements in the fields of basic research, metrology and x-ray lithography it was decided in late 1977 to build a dedicated XUV synchrotron radiation source in Berlin. The history of the BESSY project, the user-oriented factors that determined the design parameters, the construction and commissioning of the facility as well as user operation and funding issues are reviewed

  10. Active control of acoustic field-of-view in a biosonar system.

    Directory of Open Access Journals (Sweden)

    Yossi Yovel

    2011-09-01

    Full Text Available Active-sensing systems abound in nature, but little is known about systematic strategies that are used by these systems to scan the environment. Here, we addressed this question by studying echolocating bats, animals that have the ability to point their biosonar beam to a confined region of space. We trained Egyptian fruit bats to land on a target, under conditions of varying levels of environmental complexity, and measured their echolocation and flight behavior. The bats modulated the intensity of their biosonar emissions, and the spatial region they sampled, in a task-dependant manner. We report here that Egyptian fruit bats selectively change the emission intensity and the angle between the beam axes of sequentially emitted clicks, according to the distance to the target, and depending on the level of environmental complexity. In so doing, they effectively adjusted the spatial sector sampled by a pair of clicks-the "field-of-view." We suggest that the exact point within the beam that is directed towards an object (e.g., the beam's peak, maximal slope, etc. is influenced by three competing task demands: detection, localization, and angular scanning-where the third factor is modulated by field-of-view. Our results suggest that lingual echolocation (based on tongue clicks is in fact much more sophisticated than previously believed. They also reveal a new parameter under active control in animal sonar-the angle between consecutive beams. Our findings suggest that acoustic scanning of space by mammals is highly flexible and modulated much more selectively than previously recognized.

  11. Using a Monte Carlo model to predict dosimetric properties of small radiotherapy photon fields

    International Nuclear Information System (INIS)

    Scott, Alison J. D.; Nahum, Alan E.; Fenwick, John D.

    2008-01-01

    Accurate characterization of small-field dosimetry requires measurements to be made with precisely aligned specialized detectors and is thus time consuming and error prone. This work explores measurement differences between detectors by using a Monte Carlo model matched to large-field data to predict properties of smaller fields. Measurements made with a variety of detectors have been compared with calculated results to assess their validity and explore reasons for differences. Unshielded diodes are expected to produce some of the most useful data, as their small sensitive cross sections give good resolution whilst their energy dependence is shown to vary little with depth in a 15 MV linac beam. Their response is shown to be constant with field size over the range 1-10 cm, with a correction of 3% needed for a field size of 0.5 cm. BEAMnrc has been used to create a 15 MV beam model, matched to dosimetric data for square fields larger than 3 cm, and producing small-field profiles and percentage depth doses (PDDs) that agree well with unshielded diode data for field sizes down to 0.5 cm. For fields sizes of 1.5 cm and above, little detector-to-detector variation exists in measured output factors, however for a 0.5 cm field a relative spread of 18% is seen between output factors measured with different detectors--values measured with the diamond and pinpoint detectors lying below that of the unshielded diode, with the shielded diode value being higher. Relative to the corrected unshielded diode measurement, the Monte Carlo modeled output factor is 4.5% low, a discrepancy that is probably due to the focal spot fluence profile and source occlusion modeling. The large-field Monte Carlo model can, therefore, currently be used to predict small-field profiles and PDDs measured with an unshielded diode. However, determination of output factors for the smallest fields requires a more detailed model of focal spot fluence and source occlusion.

  12. Using optic flow in the far peripheral field.

    Science.gov (United States)

    McManus, Meaghan; D'Amour, Sarah; Harris, Laurence R

    2017-07-01

    Self-motion information can be used to update spatial memory of location through an estimate of a change in position. Viewing optic flow alone can create Illusory self-motion or "vection." Early studies suggested that peripheral vision is more effective than central vision in evoking vection, but controlling for retinal area and perceived distance suggests that all retinal areas may be equally effective. However, the contributions of the far periphery, beyond 90°, have been largely neglected. Using a large-field Edgeless Graphics Geometry display (EGG, Christie, Canada, field of view ±112°) and systematically blocking central (±20° to ±90°) or peripheral (viewing through tunnels ±20° to ±40°) parts of the field, we compared the effectiveness of different retinal regions at evoking forwards linear vection. Fifteen participants indicated when they had reached the position of a previously presented target after visually simulating motion down a simulated corridor. The amount of simulated travel needed to match a given target distance was modelled with a leaky spatial integrator model to estimate gains (perceived/actual distance) and a spatial decay factor. When optic flow was presented only in the far periphery (beyond 90°) gains were significantly higher than for the same motion presented full field or in only the central field, resulting in accurate performance in the range of speeds associated with normal walking. The increased effectiveness of optic flow in the peripheral field alone compared to full-field motion is discussed in terms of emerging neurophysiological studies that suggest brain areas dedicated to processing information from the far peripheral field.

  13. Detector design issues for compact nuclear emission cameras dedicated to breast imaging

    International Nuclear Information System (INIS)

    Levin, Craig S.

    2003-01-01

    Certain gamma ray and positron emitting radiotracers have shown great promise for use in the detection, diagnosis and staging of breast cancer. Unfortunately, standard nuclear emission cameras (SPECT, PET) found in the clinic are not practical for breast imaging of these emissions due to inadequate spatial and energy resolutions and sensitivity, large and awkward size, and relatively high cost per study. High spatial and energy resolutions and sensitivity are needed for good lesion detectability. Due to these limitations of standard cameras, there has been recent research into the development of small, compact nuclear emission imagers dedicated for close-proximity breast imaging. The small detector head size means a variety of exotic detectors or collimators may be implemented to improve spatial and energy resolution and sensitivity performances at a reasonable cost. In this paper, we will present some of the compact gamma ray and annihilation photon imaging detector designs that have been proposed and/or developed for dedicated breast imaging. We will review the physics and discuss the advantages and disadvantages of various detector configurations. Finally we will estimate the fundamental spatial resolution potential available with close-proximity nuclear emission imaging and discuss how one may approach those limits through proper detector design

  14. Wide field of view common-path lateral-shearing digital holographic interference microscope.

    Science.gov (United States)

    Vora, Priyanka; Trivedi, Vismay; Mahajan, Swapnil; Patel, Nimit; Joglekar, Mugdha; Chhaniwal, Vani; Moradi, Ali-Reza; Javidi, Bahram; Anand, Arun

    2017-12-01

    Quantitative three-dimensional (3-D) imaging of living cells provides important information about the cell morphology and its time variation. Off-axis, digital holographic interference microscopy is an ideal tool for 3-D imaging, parameter extraction, and classification of living cells. Two-beam digital holographic microscopes, which are usually employed, provide high-quality 3-D images of micro-objects, albeit with lower temporal stability. Common-path digital holographic geometries, in which the reference beam is derived from the object beam, provide higher temporal stability along with high-quality 3-D images. Self-referencing geometry is the simplest of the common-path techniques, in which a portion of the object beam itself acts as the reference, leading to compact setups using fewer optical elements. However, it has reduced field of view, and the reference may contain object information. Here, we describe the development of a common-path digital holographic microscope, employing a shearing plate and converting one of the beams into a separate reference by employing a pin-hole. The setup is as compact as self-referencing geometry, while providing field of view as wide as that of a two-beam microscope. The microscope is tested by imaging and quantifying the morphology and dynamics of human erythrocytes. (2017) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE).

  15. Three-dimensional magnetic nanoparticle imaging using small field gradient and multiple pickup coils

    Energy Technology Data Exchange (ETDEWEB)

    Sasayama, Teruyoshi, E-mail: sasayama@sc.kyushu-u.ac.jp; Tsujita, Yuya; Morishita, Manabu; Muta, Masahiro; Yoshida, Takashi; Enpuku, Keiji

    2017-04-01

    We propose a magnetic particle imaging (MPI) method based on third harmonic signal detection using a small field gradient and multiple pickup coils. First, we developed a system using two pickup coils and performed three-dimensional detection of two magnetic nanoparticle (MNP) samples, which were spaced 15 mm apart. In the experiments, an excitation field strength of 1.6 mT was used at an operating frequency of 3 kHz. A DC gradient field with a typical value of 0.2 T/m was also used to produce the so-called field-free line. A third harmonic signal generated by the MNP samples was detected using the two pickup coils, and the samples were then mechanically scanned to obtain field maps. The field maps were subsequently analyzed using the nonnegative least squares method to obtain three-dimensional position information for the MNP samples. The results show that the positions of the two MNP samples were estimated with good accuracy, despite the small field gradient used. Further improvement in MPI performance will be achieved by increasing the number of pickup coils used. - Highlights: • 3D magnetic particle imaging system combining field-free line and two pickup coils. • Imaging method based on third harmonic signal detection and small field gradient. • Nonnegative least squares method for 3D magnetic nanoparticle image reconstruction. • High spatial resolution despite use of small field gradient.

  16. Microwave tomography of extremities: 1. Dedicated 2D system and physiological signatures

    International Nuclear Information System (INIS)

    Semenov, Serguei; Nair, Bindu; Kellam, James; Williams, Thomas; Quinn, Michael; Sizov, Yuri; Nazarov, Alexei; Pavlovsky, Andrey; Posukh, Vitaly

    2011-01-01

    Microwave tomography (MWT) is a novel imaging modality which might be applicable for non-invasive assessment of functional and pathological conditions of biological tissues. Imaging of the soft tissue of extremities is one of its potential applications. The feasibility of this technology for such applications was demonstrated earlier. This is the first of two companion papers focused on an application of MWT for imaging of the extremity's soft tissues. The goal of this study is to assess the technical performance of the developed 2D MWT system dedicated for imaging of functional and pathological conditions of the extremity's soft tissues. Specifically, the system's performance was tested by its ability to detect signals associated with physiological activity and soft tissue interventions (circulatory related changes, blood flow reduction and a simulated compartmental syndrome)-the so-called physiological signatures. The developed 2D MWT system dedicated to the imaging of animal extremities demonstrates good technical performance allowing for stable and predictable data acquisition with reasonable agreement between the experimentally measured electromagnetic (EM) field and the simulated EM field within a measurement domain. Using the system, we were able to obtain physiological signatures associated with systolic versus diastolic phases of circulation in an animal extremity, reperfusion versus occlusion phases of the blood supply to the animal's extremity and a compartment syndrome. The imaging results are presented and discussed in the second companion paper.

  17. A RESOURCE-BASED VIEW OF SMALL EXPORT FIRMS' SOCIAL CAPITAL IN A SOUTHEAST ASIAN COUNTRY

    Directory of Open Access Journals (Sweden)

    Doren Chadee

    2011-07-01

    Full Text Available This study empirically examines the social capital that facilitates the flow of export knowledge, thereby supporting the entrepreneurial stance of small export firms. By applying the VRIO (value, rarity, inimitability and organisation of firm resources framework to the resource-based view (RBV of the firm, this study suggests that superior performance is a function of resources that are valuable, rare, inimitable and sufficiently organised to develop and sustain the firm's competitive advantage. This study argues that small, resource-constrained export firms in a developing economy are able to adopt entrepreneurial tactics and reap positive rates of return by exploiting their relational capital to acquire export knowledge. A survey of 175 small export firms in the Philippines was conducted, and the data were analysed using structural equation modelling. The results suggest positive relationships between the firm's social capital and export knowledge. Export knowledge is associated with entrepreneurial orientation, which then correlates with export performance.

  18. mxCSM: A 100-slit, 6-Wavelength Wide-Field Coronal Spectropolarimeter for the Study of the Dynamics and the Magnetic Fields of the Solar Corona

    Energy Technology Data Exchange (ETDEWEB)

    Lin, Haosheng, E-mail: lin@ifa.hawaii.edu [Institute for Astronomy, University of Hawaii, Pukalani, HI (United States)

    2016-03-30

    Tremendous progress has been made in the field of observational coronal magnetometry in the first decade of the Twenty-First century. With the successful construction of the Coronal Multichannel Magnetometer (CoMP) instrument, observations of the linear polarization of the coronal emission lines (CELs), which carry information about the azimuthal direction of the coronal magnetic fields, are now routinely available. However, reliable and regular measurements of the circular polarization signals of the CELs remain illusive. The CEL circular polarization signals allow us to infer the magnetic field strength in the corona, and is critically important for our understanding of the solar corona. Current telescopes and instrument can only measure the coronal magnetic field strength over a small field of view. Furthermore, the observations require very long integration time that preclude the study of dynamic events even when only a small field of view is required. This paper describes a new instrument concept that employs large-scale multiplexing technology to enhance the efficiency of current coronal spectropolarimeter by more than two orders of magnitude. This will allow for the instrument to increase the integration time at each spatial location by the same factor, while also achieving a large field of view coverage. We will present the conceptual design of a 100-slit coronal spectropolarimeter that can observe six CELs simultaneously. Instruments based on this concept will allow us to study the evolution of the coronal magnetic field even with coronagraphs with modest aperture.

  19. Colorado Ultraviolet Transit Experiment: a dedicated CubeSat mission to study exoplanetary mass loss and magnetic fields

    Science.gov (United States)

    Fleming, Brian T.; France, Kevin; Nell, Nicholas; Kohnert, Richard; Pool, Kelsey; Egan, Arika; Fossati, Luca; Koskinen, Tommi; Vidotto, Aline A.; Hoadley, Keri; Desert, Jean-Michel; Beasley, Matthew; Petit, Pascal M.

    2018-01-01

    The Colorado Ultraviolet Transit Experiment (CUTE) is a near-UV (2550 to 3300 Å) 6U CubeSat mission designed to monitor transiting hot Jupiters to quantify their atmospheric mass loss and magnetic fields. CUTE will probe both atomic (Mg and Fe) and molecular (OH) lines for evidence of enhanced transit absorption, and to search for evidence of early ingress due to bow shocks ahead of the planet's orbital motion. As a dedicated mission, CUTE will observe ≳100 spectroscopic transits of hot Jupiters over a nominal 7-month mission. This represents the equivalent of >700 orbits of the only other instrument capable of these measurements, the Hubble Space Telescope. CUTE efficiently utilizes the available CubeSat volume by means of an innovative optical design to achieve a projected effective area of ˜28 cm2, low instrumental background, and a spectral resolving power of R˜3000 over the primary science bandpass. These performance characteristics enable CUTE to discern transit depths between 0.1% and 1% in individual spectral absorption lines. We present the CUTE optical and mechanical design, a summary of the science motivation and expected results, and an overview of the projected fabrication, calibration, and launch timeline.

  20. Fast, large field-of-view, telecentric optical-CT scanning system for 3D radiochromic dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Thomas, A; Oldham, M, E-mail: ast5@duke.ed [Department of Radiation Oncology, Duke University Medical Center, Durham, NC (United States)

    2010-11-01

    We describe initial experiences with an in-house, fast, large field-of-view optical-CT telecentric scanner (the Duke Large field of view Optical-CT Scanner (DLOS)). The DLOS system is designed to enable telecentric optical-CT imaging of dosimeters up to 24 cm in diameter with a spatial resolution of 1 mm{sup 3}, in approximately 10 minutes. These capabilities render the DLOS system a unique device at present. The system is a scaled up version of early prototypes in our lab. This scaling introduces several challenges, including the accurate measurement of a greatly increased range of light attenuation within the dosimeter, and the need to reduce even minor reflections and scattered light within the imaging chain. We present several corrections and techniques that enable accurate, low noise, 3D dosimetery with the DLOS system.

  1. The marketing strategy of a small enterprise

    Directory of Open Access Journals (Sweden)

    Trandafilović Igor

    2008-01-01

    Full Text Available Small enterprise shows some specific characteristics which are necessary for creation of marketing strategy. The goal of this work is an attempt of marketing strategy analysis of the small enterprises. The necessary request of the analysis is to define the small enterprise. There have also been analyzed the specific orders for small enterpriser. Special part of work is dedicated to a small enterprises management strategy and the other one to their marketing communications. There are mentioned some specific advantages and problems of the small enterprises, too.

  2. Revision to dedicated short range communication roadside equipment specification - RSU 4.1.Bench Test Plan.

    Science.gov (United States)

    2017-04-28

    The document describes the overall process for evaluating Dedicated Short Range Communication (DSRC) Roadside Units (RSU) against USDOT RSU Specification 4.1 in preparation for field evaluation. The Test Cases contained in this document only evaluate...

  3. Standards for Measurements in the Field of High Frequency Electromagnetic Radiation for the Purpose of Protection Against Adverse Health Effects

    International Nuclear Information System (INIS)

    Tanatarec, B.; Nikolic, N.

    2011-01-01

    In this paper standards for measurements in the field of high frequency electromagnetic radiation are described with a view to protection from its hazardous action. Beside the standards which directly deal with high frequency electromagnetic radiation measurements, guidelines which describe hazardous influences of high frequency electromagnetic radiation on human body in the form of specific absorption rate (SAR) are given. Special attention is dedicated to standards and regulations, which are dealing with social responsibility, as well as with social responsibility in the field of high frequency radiation. This area is new and insufficiently known, rarely extended in everyday life. (author)

  4. Equilibrium Eulerian approach for predicting the thermal field of a dispersion of small particles

    Energy Technology Data Exchange (ETDEWEB)

    Ferry, J. [University of Illinois, Urbana-Champaign, IL (United States). Center for Simulation of Advanced Rockets; Balachandar, S. [University of Illinois, Urbana-Champaign, IL (United States). Dept. of Theoretical and Applied Mechanics

    2005-02-01

    The equilibrium Eulerian method [J. Ferry, S. Balachandar, A fast Eulerian method for disperse two-phase flow, Int. J. Multiphase Flow 27 (7) (2001) 1199-1226] provides an accurate approximation to the velocity field of sufficiently small dispersed particles in a turbulent fluid. In particular, it captures the important physics of particle response to turbulent flow, such as preferential concentration and turbophoresis. It is therefore employed as an efficient alternative to solving a PDE to determine the particle velocity field. Here we explore two possible extensions of this method to determine the particle temperature field accurately and efficiently, as functions of the underlying fluid velocity and temperature fields. Both extensions are theoretically shown to be highly accurate for asymptotically small particles. Their behavior for finite-size particles is assessed in a DNS of turbulent channel flow (Re{sub {tau}} = 150) with a passive temperature field (Pr = 1). Here it is found that although the order of accuracy of the two extensions is the same, the constant factor by which one is superior to the other can be quite large, so the less accurate extension is appropriate only in the case of a very small mechanical-to-thermal response time ratio. (Author)

  5. Electrical characterization of FBK small-pitch 3D sensors after γ-ray, neutron and proton irradiations

    Science.gov (United States)

    Dalla Betta, G.-F.; Boscardin, M.; Hoeferkamp, M.; Mendicino, R.; Seidel, S.; Sultan, D. M. S.

    2017-11-01

    In view of applications in the tracking detectors at the High Luminosity LHC (HL-LHC), we have developed a new generation of 3D pixel sensors featuring small-pitch (50 × 50 or 25 × 100 μ m2) and thin active layer (~ 100 μ m). Owing to the very short inter-electrode distance (~ 30 μ m), charge trapping effects can be strongly mitigated, making these sensors extremely radiation hard. However, the downscaled sensor structure also lends itself to high electric fields as the bias voltage is increased, motivating investigation of leakage current increase in order to prevent premature electrical breakdown due to impact ionization. In order to assess the characteristics of heavily irradiated samples, using 3D diodes as test devices, we have carried out a dedicated campaign that included several irradiations (γ -rays, neutrons, and protons) at different facilities. In this paper, we report on the electrical characterization of a subset of the irradiated samples, also in comparison to their pre-irradiation properties. Results demonstrate that hadron irradiated devices can be safely operated at a voltage high enough to allow for full depletion (hence high efficiency) also at the maximum fluence foreseen at the HL-LHC.

  6. Multiple scattering corrections to the Beer-Lambert law. 2: Detector with a variable field of view.

    Science.gov (United States)

    Zardecki, A; Tam, W G

    1982-07-01

    The multiple scattering corrections to the Beer-Lambert law in the case of a detector with a variable field of view are analyzed. We introduce transmission functions relating the received radiant power to reference power levels relevant to two different experimental situations. In the first case, the transmission function relates the received power to a reference power level appropriate to a nonattenuating medium. In the second case, the reference power level is established by bringing the receiver to the close-up position with respect to the source. To examine the effect of the variation of the detector field of view the behavior of the gain factor is studied. Numerical results modeling the laser beam propagation in fog, cloud, and rain are presented.

  7. Strategy for optimal side-branch positioning of bioresorbable vascular scaffolds in dedicated 2-stent techniques: Insights from optical coherence tomography

    International Nuclear Information System (INIS)

    Miyazaki, Tadashi; Costopoulos, Charis; Sato, Katsumasa; Naganuma, Toru; Panoulas, Vasileios F.; Figini, Filippo; Latib, Azeem; Colombo, Antonio

    2014-01-01

    We present a case of a left anterior descending artery/diagonal branch bifurcation successfully treated with a dedicated 2-stent technique utilizing bioresorbable vascular scaffolds, where the bifurcation angle did not strictly allow a T-stenting approach. We also propose a strategy to avoid or reduce scaffold overlap in the main branch, especially important in view of the bulkier size of these novel devices

  8. The Colorado Ultraviolet Transit Experiment (CUTE): a dedicated cubesat mission for the study of exoplanetary mass loss and magnetic fields

    Science.gov (United States)

    Fleming, Brian T.; France, Kevin; Nell, Nicholas; Kohnert, Richard; Pool, Kelsey; Egan, Arika; Fossati, Luca; Koskinen, Tommi; Vidotto, Aline A.; Hoadley, Keri; Desert, Jean-Michel; Beasley, Matthew; Petit, Pascal

    2017-08-01

    The Colorado Ultraviolet Transit Experiment (CUTE) is a near-UV (2550 - 3300 Å) 6U cubesat mission designed to monitor transiting hot Jupiters to quantify their atmospheric mass loss and magnetic fields. CUTE will probe both atomic (Mg and Fe) and molecular (OH) lines for evidence of enhanced transit absorption, and to search for evidence of early ingress due to bow shocks ahead of the planet's orbital motion. As a dedicated mission, CUTE will observe > 60 spectroscopic transits of hot Jupiters over a nominal seven month mission. This represents the equivalent of > 700 orbits of the only other instrument capable of these measurements, the Hubble Space Telescope. CUTE efficiently utilizes the available cubesat volume by means of an innovative optical design to achieve a projected effective area of ˜ 22 cm2 , low instrumental background, and a spectral resolving power of R ˜ 3000 over the entire science bandpass. These performance characteristics enable CUTE to discern a transit depth of motivation and expected results, and an overview of the projected fabrication, calibration and launch timeline.

  9. Error Analysis and Calibration Method of a Multiple Field-of-View Navigation System

    OpenAIRE

    Shi, Shuai; Zhao, Kaichun; You, Zheng; Ouyang, Chenguang; Cao, Yongkui; Wang, Zhenzhou

    2017-01-01

    The Multiple Field-of-view Navigation System (MFNS) is a spacecraft subsystem built to realize the autonomous navigation of the Spacecraft Inside Tiangong Space Station. This paper introduces the basics of the MFNS, including its architecture, mathematical model and analysis, and numerical simulation of system errors. According to the performance requirement of the MFNS, the calibration of both intrinsic and extrinsic parameters of the system is assumed to be essential and pivotal. Hence, a n...

  10. The effect of internal and external fields of view on visually induced motion sickness.

    Science.gov (United States)

    Bos, Jelte E; de Vries, Sjoerd C; van Emmerik, Martijn L; Groen, Eric L

    2010-07-01

    Field of view (FOV) is said to affect visually induced motion sickness. FOV, however, is characterized by an internal setting used by the graphics generator (iFOV) and an external factor determined by screen size and viewing distance (eFOV). We hypothesized that especially the incongruence between iFOV and eFOV would lead to sickness. To that end we used a computer game environment with different iFOV and eFOV settings, and found the opposite effect. We speculate that the relative large differences between iFOV and eFOV used in this experiment caused the discrepancy, as may be explained by assuming an observer model controlling body motion. Copyright 2009 Elsevier Ltd. All rights reserved.

  11. Multimode simulations of a wide field of view double-Fourier far-infrared spatio-spectral interferometer

    Science.gov (United States)

    Bracken, Colm P.; Lightfoot, John; O'Sullivan, Creidhe; Murphy, J. Anthony; Donohoe, Anthony; Savini, Giorgio; Juanola-Parramon, Roser; The Fisica Consortium, On Behalf Of

    2018-01-01

    In the absence of 50-m class space-based observatories, subarcsecond astronomy spanning the full far-infrared wavelength range will require space-based long-baseline interferometry. The long baselines of up to tens of meters are necessary to achieve subarcsecond resolution demanded by science goals. Also, practical observing times command a field of view toward an arcminute (1‧) or so, not achievable with a single on-axis coherent detector. This paper is concerned with an application of an end-to-end instrument simulator PyFIInS, developed as part of the FISICA project under funding from the European Commission's seventh Framework Programme for Research and Technological Development (FP7). Predicted results of wide field of view spatio-spectral interferometry through simulations of a long-baseline, double-Fourier, far-infrared interferometer concept are presented and analyzed. It is shown how such an interferometer, illuminated by a multimode detector can recover a large field of view at subarcsecond angular resolution, resulting in similar image quality as that achieved by illuminating the system with an array of coherent detectors. Through careful analysis, the importance of accounting for the correct number of higher-order optical modes is demonstrated, as well as accounting for both orthogonal polarizations. Given that it is very difficult to manufacture waveguide and feed structures at sub-mm wavelengths, the larger multimode design is recommended over the array of smaller single mode detectors. A brief note is provided in the conclusion of this paper addressing a more elegant solution to modeling far-infrared interferometers, which holds promise for improving the computational efficiency of the simulations presented here.

  12. Remote viewing.

    Science.gov (United States)

    Scott, C

    1988-04-15

    Remote viewing is the supposed faculty which enables a percipient, sited in a closed room, to describe the perceptions of a remote agent visiting an unknown target site. To provide convincing demonstration of such a faculty poses a range of experimental and practical problems, especially if feedback to the percipient is allowed after each trial. The precautions needed are elaborate and troublesome; many potential loopholes have to be plugged and there will be strong temptations to relax standards, requiring exceptional discipline and dedication by the experimenters. Most reports of remote viewing experiments are rather superficial and do not permit assessment of the experimental procedures with confidence; in many cases there is clear evidence of particular loopholes left unclosed. Any serious appraisal of the evidence would have to go beyond the reports. Meanwhile the published evidence is far from compelling, and certainly insufficient to justify overthrow of well-established scientific principles.

  13. New quantitative and multi-modal approach for in-vivo studies of small animals: coupling of the β-microprobe with magnetic techniques and development of voxelized rat and mouse phantoms

    International Nuclear Information System (INIS)

    Desbree, A.

    2005-09-01

    For the last 15 years, animal models that mimic human disorders have become ubiquitous participants to understand biological mechanisms and human disorders and to evaluate new therapeutic approaches. The necessity to study these models in the course of time has stimulated the development of instruments dedicated to in vivo small animal studies. To further understand physiopathological processes, the current challenge is to couple simultaneously several of these methods. Given this context, the combination of the magnetic and radioactive techniques remains an exciting challenge since it is still limited by strict technical constraints. Therefore we propose to couple the magnetic techniques with the radiosensitive Beta-Microprobe, developed in the IPB group and which shown to be an elegant alternative to PET measurements. In this context, the thesis was dedicated to the study of the coupling feasibility from a physical point of view, by simulation and experimental characterizations. Then, the determination of a biological protocol was carried out on the basis of pharmacokinetic studies. The experiments have shown the possibility to use the probe for radioactive measurements under intense magnetic field simultaneously to anatomical images acquisitions. Simultaneously, we have sought to improve the quantification of the radioactive signal using a voxelized phantom of a rat brain. Finally, the emergence of transgenic models led us to reproduce pharmacokinetic studies for the mouse and to develop voxelized mouse phantoms. (author)

  14. Wide-band acousto-optic deflectors for large field of view two-photon microscope.

    Science.gov (United States)

    Jiang, Runhua; Zhou, Zhenqiao; Lv, Xiaohua; Zeng, Shaoqun

    2012-04-01

    Acousto-optic deflector (AOD) is an attractive scanner for two-photon microscopy because it can provide fast and versatile laser scanning and does not involve any mechanical movements. However, due to the small scan range of available AOD, the field of view (FOV) of the AOD-based microscope is typically smaller than that of the conventional galvanometer-based microscope. Here, we developed a novel wide-band AOD to enlarge the scan angle. Considering the maximum acceptable acoustic attenuation in the acousto-optic crystal, relatively lower operating frequencies and moderate aperture were adopted. The custom AOD was able to provide 60 MHz 3-dB bandwidth and 80% peak diffraction efficiency at 840 nm wavelength. Based on a pair of such AOD, a large FOV two-photon microscope was built with a FOV up to 418.5 μm (40× objective). The spatiotemporal dispersion was compensated simultaneously with a single custom-made prism. By means of dynamic power modulation, the variation of laser intensity within the FOV was reduced below 5%. The lateral and axial resolution of the system were 0.58-2.12 μm and 2.17-3.07 μm, respectively. Pollen grain images acquired by this system were presented to demonstrate the imaging capability at different positions across the entire FOV. © 2012 American Institute of Physics

  15. Screening small-molecule compound microarrays for protein ligands without fluorescence labeling with a high-throughput scanning microscope

    OpenAIRE

    Fei, Yiyan; Landry, James P.; Sun, Yungshin; Zhu, Xiangdong; Wang, Xiaobing; Luo, Juntao; Wu, Chun-Yi; Lam, Kit S.

    2010-01-01

    We describe a high-throughput scanning optical microscope for detecting small-molecule compound microarrays on functionalized glass slides. It is based on measurements of oblique-incidence reflectivity difference and employs a combination of a y-scan galvometer mirror and an x-scan translation stage with an effective field of view of 2 cm×4 cm. Such a field of view can accommodate a printed small-molecule compound microarray with as many as 10,000 to 20,000 targets. The scanning microscope is...

  16. TU-F-BRE-05: Experimental Determination of K Factor in Small Field Dosimetry

    International Nuclear Information System (INIS)

    Das, I; Akino, Y; Francescon, P

    2014-01-01

    Purpose: Small-field dosimetry is challenging due to charged-particle disequilibrium, source occlusion and more importantly finite size of detectors. IAEA/AAPM has published approach to convert detector readings to dose by k factor. Manufacturers have been trying to provide various types of micro-detectors that could be used in small fields. However k factors depends on detector perturbations and are derived using Monte Carlo simulation. PTW has introduced a microDiamond for small-field dosimetry. An experimental approach is presented to derive the k factor for this detector. Methods: PTW microDiamond is a small volume detector with 1.1 mm radius and 1.0 micron thick synthetic diamond. Output factors were measured from 1×1cm2 to 12×12 cm2 on a Varian machine at various depths using various micro-detectors with published k factors. Dose is calculated as reading * K. Assuming k factor is accurate, output factor should be identical with every micro-detectors. Hence published k values (Francescon et al Med Phys 35, 504-513,2008) were used to covert readings and then output factors were computed. Based on the converged curve from other detectors, k factor for microDiamond was computed versus field size. Results: Traditional output factors as ratio of readings normalized to 10×10 cm2 differ significantly for micro-detectors for fields smaller than 3×3 cm2 which are now being used extensively. When readings are converted to dose, the output factor is independent of detector. Based on this method, k factor for microDiamond was estimated to be nearly constant 0.993±0.007 over varied field sizes. Conclusion: Our method provides a unique opportunity to determine the k factor for any unknown detector. It is shown that even though k factor depends on machine type due to focal spot, however for fields ≥1×1 cm2 this method provides accurate evaluation of k factor. Additionally microDiamond could be used with assumption that k factor is nearly unity

  17. Current-voltage characteristics of a superconducting slab under a superimposed small AC magnetic field

    International Nuclear Information System (INIS)

    Matsushita, Teruo; Yamafuji, Kaoru; Sakamoto, Nobuyoshi.

    1977-01-01

    In case of applying superconductors to electric machinery or high intensity field magnets for fusion reactors, the superconductors are generally expected to be sensible to small field fluctuation besides DC magnetic field. The behavior of superconductors in DC magnetic field superimposed with small AC magnetic field has been investigated often experimentally, and the result has been obtained that the critical current at which DC flow voltage begins to appear extremely decreased or disappeared. Some theoretical investigations have been carried out on this phenomenon so far, however, their application has been limited to the region where frequency is sufficiently low or which is close to the critical magnetic field. Purpose of this report is to deal with the phenomenon in more unified way by analyzing the behavior of magnetic flux lines in a superconductor under a superimposed small AC field using the criticalstate model including viscous force. In order to solve the fundamental equation in this report, first the solution has been obtained in the quasi-static state neglecting viscous force, then about the cases that current density J is not more than Jc and J is larger than Jc, concerning the deviation from the quasi-static limit by employing successive approximation. Current-voltage characteristics have been determined by utilizing the above results. This method seems to be most promising at present except the case of extremely high frequency. (Wakatsuki, Y.)

  18. WiseView: Visualizing motion and variability of faint WISE sources

    Science.gov (United States)

    Caselden, Dan; Westin, Paul, III; Meisner, Aaron; Kuchner, Marc; Colin, Guillaume

    2018-06-01

    WiseView renders image blinks of Wide-field Infrared Survey Explorer (WISE) coadds spanning a multi-year time baseline in a browser. The software allows for easy visual identification of motion and variability for sources far beyond the single-frame detection limit, a key threshold not surmounted by many studies. WiseView transparently gathers small image cutouts drawn from many terabytes of unWISE coadds, facilitating access to this large and unique dataset. Users need only input the coordinates of interest and can interactively tune parameters including the image stretch, colormap and blink rate. WiseView was developed in the context of the Backyard Worlds: Planet 9 citizen science project, and has enabled hundreds of brown dwarf candidate discoveries by citizen scientists and professional astronomers.

  19. Molecular Imaging in Breast Cancer: From Whole-Body PET/CT to Dedicated Breast PET

    Directory of Open Access Journals (Sweden)

    B. B. Koolen

    2012-01-01

    Full Text Available Positron emission tomography (PET, with or without integrated computed tomography (CT, using 18F-fluorodeoxyglucose (FDG is based on the principle of elevated glucose metabolism in malignant tumors, and its use in breast cancer patients is frequently being investigated. It has been shown useful for classification, staging, and response monitoring, both in primary and recurrent disease. However, because of the partial volume effect and limited resolution of most whole-body PET scanners, sensitivity for the visualization of small tumors is generally low. To improve the detection and quantification of primary breast tumors with FDG PET, several dedicated breast PET devices have been developed. In this nonsystematic review, we shortly summarize the value of whole-body PET/CT in breast cancer and provide an overview of currently available dedicated breast PETs.

  20. Exact iterative reconstruction for the interior problem

    International Nuclear Information System (INIS)

    Zeng, Gengsheng L; Gullberg, Grant T

    2009-01-01

    There is a trend in single photon emission computed tomography (SPECT) that small and dedicated imaging systems are becoming popular. For example, many companies are developing small dedicated cardiac SPECT systems with different designs. These dedicated systems have a smaller field of view (FOV) than a full-size clinical system. Thus data truncation has become the norm rather than the exception in these systems. Therefore, it is important to develop region of interest (ROI) reconstruction algorithms using truncated data. This paper is a stepping stone toward this direction. This paper shows that the common generic iterative image reconstruction algorithms are able to exactly reconstruct the ROI under the conditions that the convex ROI is fully sampled and the image value in a sub-region within the ROI is known. If the ROI includes a sub-region that is outside the patient body, then the conditions can be easily satisfied.

  1. The evaluation of single-view and multi-view fusion 3D echocardiography using image-driven segmentation and tracking.

    Science.gov (United States)

    Rajpoot, Kashif; Grau, Vicente; Noble, J Alison; Becher, Harald; Szmigielski, Cezary

    2011-08-01

    Real-time 3D echocardiography (RT3DE) promises a more objective and complete cardiac functional analysis by dynamic 3D image acquisition. Despite several efforts towards automation of left ventricle (LV) segmentation and tracking, these remain challenging research problems due to the poor-quality nature of acquired images usually containing missing anatomical information, speckle noise, and limited field-of-view (FOV). Recently, multi-view fusion 3D echocardiography has been introduced as acquiring multiple conventional single-view RT3DE images with small probe movements and fusing them together after alignment. This concept of multi-view fusion helps to improve image quality and anatomical information and extends the FOV. We now take this work further by comparing single-view and multi-view fused images in a systematic study. In order to better illustrate the differences, this work evaluates image quality and information content of single-view and multi-view fused images using image-driven LV endocardial segmentation and tracking. The image-driven methods were utilized to fully exploit image quality and anatomical information present in the image, thus purposely not including any high-level constraints like prior shape or motion knowledge in the analysis approaches. Experiments show that multi-view fused images are better suited for LV segmentation and tracking, while relatively more failures and errors were observed on single-view images. Copyright © 2011 Elsevier B.V. All rights reserved.

  2. Commercial Grade Item (CGI) dedication - on complex electronic equipment

    International Nuclear Information System (INIS)

    Sohn, Kwang Young; Kim, Joong Han; Koo, In Soo; Lee, Sang Yong

    2008-01-01

    In future more complicated IT-based hardware and software is supposed to used in the safety-grade systems in nuclear power plants. Also there are the efforts to establish the criteria for CGI dedications in NRC and CEC dedication in other standard organizations. The highly complicated components, i.e. CEC should be dedication plans. Thus work to be done in later is to prepare the strategies, plans, guide and procedures that is more specific for CEC dedication

  3. Scalable cloud without dedicated storage

    Science.gov (United States)

    Batkovich, D. V.; Kompaniets, M. V.; Zarochentsev, A. K.

    2015-05-01

    We present a prototype of a scalable computing cloud. It is intended to be deployed on the basis of a cluster without the separate dedicated storage. The dedicated storage is replaced by the distributed software storage. In addition, all cluster nodes are used both as computing nodes and as storage nodes. This solution increases utilization of the cluster resources as well as improves fault tolerance and performance of the distributed storage. Another advantage of this solution is high scalability with a relatively low initial and maintenance cost. The solution is built on the basis of the open source components like OpenStack, CEPH, etc.

  4. Time-Varying Biased Proportional Guidance with Seeker’s Field-of-View Limit

    OpenAIRE

    Yang, Zhe; Wang, Hui; Lin, Defu

    2016-01-01

    Traditional guidance laws with range-to-go information or time-to-go estimation may not be implemented in passive homing missiles since passive seekers cannot measure relative range directly. A time-varying biased proportional guidance law, which only uses line-of-sight (LOS) rate and look angle information, is proposed to satisfy both impact angle constraint and seeker’s field-of-view (FOV) limit. In the proposed guidance law, two time-varying bias terms are applied to divide the trajectory ...

  5. MODELING THE SUN’S SMALL-SCALE GLOBAL PHOTOSPHERIC MAGNETIC FIELD

    Energy Technology Data Exchange (ETDEWEB)

    Meyer, K. A. [Division of Computing and Mathematics, Abertay University, Kydd Building, Dundee, Bell Street, DD1 1HG, Scotland (United Kingdom); Mackay, D. H., E-mail: k.meyer@abertay.ac.uk [School of Mathematics and Statistics, University of St Andrews, North Haugh, St Andrews, KY16 9SS, Scotland (United Kingdom)

    2016-10-20

    We present a new model for the Sun’s global photospheric magnetic field during a deep minimum of activity, in which no active regions emerge. The emergence and subsequent evolution of small-scale magnetic features across the full solar surface is simulated, subject to the influence of a global supergranular flow pattern. Visually, the resulting simulated magnetograms reproduce the typical structure and scale observed in quiet Sun magnetograms. Quantitatively, the simulation quickly reaches a steady state, resulting in a mean field and flux distribution that are in good agreement with those determined from observations. A potential coronal magnetic field is extrapolated from the simulated full Sun magnetograms to consider the implications of such a quiet photospheric magnetic field on the corona and inner heliosphere. The bulk of the coronal magnetic field closes very low down, in short connections between small-scale features in the simulated magnetic network. Just 0.1% of the photospheric magnetic flux is found to be open at 2.5 R {sub ⊙}, around 10–100 times less than that determined for typical Helioseismic and Magnetic Imager synoptic map observations. If such conditions were to exist on the Sun, this would lead to a significantly weaker interplanetary magnetic field than is currently observed, and hence a much higher cosmic ray flux at Earth.

  6. mxCSM: A 100-slit, 6-wavelength wide-field coronal spectropolarimeter for the study of the dynamics and the magnetic fields of the solar corona

    Directory of Open Access Journals (Sweden)

    Haosheng eLin

    2016-03-01

    Full Text Available remendous progress has been made in the field of observational coronal magnetometry in the first decade of the 21st century. With the successful construction of the Coronal Multichannel Magnetometer (CoMP instrument, observations of the linear polarization of the coronal emission lines (CELs, which carry information about the azimuthal direction of the coronal magnetic fields, are now routinely available. However, reliable and regular measurements of the circular polarization signals of the CELs remain illusive. The CEL circular polarization signals allow us to infer the magnetic field strength in the corona, and is critically important {bf of} our understanding of the solar corona. Current telescopes and instrument can only measure the coronal magnetic field strength over a small field of view. Furthermore, the observations require very long integration time that preclude the study of dynamic events even when only a small field of view is required. This paper describes a new instrument concept that employees large-scale multiplexing technology to enhance the efficiency of current coronal spectropolarimeter by more than two orders of magnitude. This will allow for the instrument to increase of the integration time at each spatial location by the same factor, while also achieving a large field of view coverage. We will present the conceptual design of a 100-slit coronal spectropolarimeter that can observe six coronal emission lines simultaneously. Instruments based on this concept will allow us to study the evolution of the coronal magnetic field even with coronagraphs with modest aperture.

  7. Design and development of a high resolution animal SPECT scanner dedicated for rat and mouse imaging

    International Nuclear Information System (INIS)

    Sajedi, Salar; Zeraatkar, Navid; Moji, Vahideh; Farahani, Mohammad Hossein; Sarkar, Saeed; Arabi, Hossein; Teymoorian, Behnoosh; Ghafarian, Pardis; Rahmim, Arman; Reza Ay, Mohammad

    2014-01-01

    A dedicated small-animal SPECT system, HiReSPECT, was designed and developed to provide a high resolution molecular imaging modality in response to growing research demands. HiReSPECT is a dual-head system mounted on a rotating gantry. The detection system is based on pixelated CsI(Na) scintillator crystals coupled to two Hamamatsu H8500 Position Sensitive Photomultiplier Tubes in each head. Also, a high resolution parallel-hole collimator is applied to every head. The dimensions of each head are 50 mm×100 mm, enabling sufficient transaxial and axial fields-of-view (TFOV and AFOV), respectively, for coverage of the entire mouse in single-bed position imaging. However, a 50 mm TFOV is not sufficient for transaxial coverage of rats. To address this, each head can be rotated by 90 degrees in order to align the larger dimension of the heads with the short body axis, allowing tomographic data acquisition for rats. An innovative non-linear recursive filter was used for signal processing/detection. Resolution recovery was also embedded in the modified Maximum-Likelihood Expectation Maximization (MLEM) image reconstruction code to compensate for Collimator-Detector Response (CDR). Moreover, an innovative interpolation algorithm was developed to speed up the reconstruction code. The planar spatial resolution at the head surface and the image spatial resolutions were 1.7 mm and 1.2–1.6 mm, respectively. The measurements followed by post-processing showed that the observed count rate at 20% count loss is about 42 kcps. The system sensitivity at the collimator surface for heads 1 and 2 were 1.32 cps/µCi and 1.25 cps/µCi, respectively. The corresponding values were 1.18 cps/µCi and 1.02 cps/µCi at 8 cm distance from the collimator surfaces. In addition, whole-body scans of mice demonstrated appropriate imaging capability of the HiReSPECT

  8. Diffusion of test particles in stochastic magnetic fields for small Kubo numbers

    International Nuclear Information System (INIS)

    Neuer, Marcus; Spatschek, Karl H.

    2006-01-01

    Motion of charged particles in a collisional plasma with stochastic magnetic field lines is investigated on the basis of the so-called A-Langevin equation. Compared to the previously used V-Langevin model, here finite Larmor radius effects are taken into account. The A-Langevin equation is solved under the assumption that the Lagrangian correlation function for the magnetic field fluctuations is related to the Eulerian correlation function (in Gaussian form) via the Corrsin approximation. The latter is justified for small Kubo numbers. The velocity correlation function, being averaged with respect to the stochastic variables including collisions, leads to an implicit differential equation for the mean square displacement. From the latter, different transport regimes, including the well-known Rechester-Rosenbluth diffusion coefficient, are derived. Finite Larmor radius contributions show a decrease of the diffusion coefficient compared to the guiding center limit. The case of small (or vanishing) mean fields is also discussed

  9. LauncherOne Small Launch Vehicle Propulsion Advancement

    Data.gov (United States)

    National Aeronautics and Space Administration — Virgin Orbit, LLC (“Virgin Orbit”) is currently well into the development for our LauncherOne (L1) small satellite launch vehicle. LauncherOne is a dedicated small...

  10. TH-EF-204-00: AAPM-AMPR (Russia)-SEFM (Spain) Joint Course On Challenges and Advantages of Small Field Radiation Treatment Techniques

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2016-06-15

    Joanna E. Cygler, Jan Seuntjens, J. Daniel Bourland, M. Saiful Huq, Josep Puxeu Vaque, Daniel Zucca Aparicio, Tatiana Krylova, Yuri Kirpichev, Eric Ford, Caridad Borras Stereotactic Radiation Therapy (SRT) utilizes small static and dynamic (IMRT) fields, to successfully treat malignant and benign diseases using techniques such as Stereotactic Radiosurgery (SRS) and Stereotactic Body Radiation Therapy (SBRT). SRT is characterized by sharp dose gradients for individual fields and their resultant dose distributions. For appropriate targets, small field radiotherapy offers improved treatment quality by allowing better sparing of organs at risk while delivering the prescribed target dose. Specialized small field treatment delivery systems, such as robotic-controlled linear accelerators, gamma radiosurgery units, and dynamic arc linear accelerators may utilize rigid fixation, image guidance, and tumor tracking, to insure precise dose delivery to static or moving targets. However, in addition to great advantages, small field delivery techniques present special technical challenges for dose calibration due to unique geometries and small field sizes not covered by existing reference dosimetry protocols such as AAPM TG-51 or IAEA TRS 398. In recent years extensive research has been performed to understand small field dosimetry and measurement instrumentation. AAPM, IAEA and ICRU task groups are expected to provide soon recommendations on the dosimetry of small radiation fields. In this symposium we will: 1] discuss the physics, instrumentation, methodologies and challenges for small field radiation dose measurements; 2] review IAEA and ICRU recommendations on prescribing, recording and reporting of small field radiation therapy; 3] discuss selected clinical applications and technical aspects for specialized image-guided, small field, linear accelerator based treatment techniques such as IMRT and SBRT. Learning Objectives: To learn the physics of small fields in contrast to

  11. TH-EF-204-00: AAPM-AMPR (Russia)-SEFM (Spain) Joint Course On Challenges and Advantages of Small Field Radiation Treatment Techniques

    International Nuclear Information System (INIS)

    2016-01-01

    Joanna E. Cygler, Jan Seuntjens, J. Daniel Bourland, M. Saiful Huq, Josep Puxeu Vaque, Daniel Zucca Aparicio, Tatiana Krylova, Yuri Kirpichev, Eric Ford, Caridad Borras Stereotactic Radiation Therapy (SRT) utilizes small static and dynamic (IMRT) fields, to successfully treat malignant and benign diseases using techniques such as Stereotactic Radiosurgery (SRS) and Stereotactic Body Radiation Therapy (SBRT). SRT is characterized by sharp dose gradients for individual fields and their resultant dose distributions. For appropriate targets, small field radiotherapy offers improved treatment quality by allowing better sparing of organs at risk while delivering the prescribed target dose. Specialized small field treatment delivery systems, such as robotic-controlled linear accelerators, gamma radiosurgery units, and dynamic arc linear accelerators may utilize rigid fixation, image guidance, and tumor tracking, to insure precise dose delivery to static or moving targets. However, in addition to great advantages, small field delivery techniques present special technical challenges for dose calibration due to unique geometries and small field sizes not covered by existing reference dosimetry protocols such as AAPM TG-51 or IAEA TRS 398. In recent years extensive research has been performed to understand small field dosimetry and measurement instrumentation. AAPM, IAEA and ICRU task groups are expected to provide soon recommendations on the dosimetry of small radiation fields. In this symposium we will: 1] discuss the physics, instrumentation, methodologies and challenges for small field radiation dose measurements; 2] review IAEA and ICRU recommendations on prescribing, recording and reporting of small field radiation therapy; 3] discuss selected clinical applications and technical aspects for specialized image-guided, small field, linear accelerator based treatment techniques such as IMRT and SBRT. Learning Objectives: To learn the physics of small fields in contrast to

  12. SU-E-T-432: Field Size Influence On the Electron and Photon Spectra Within Small MV Field Detectors

    Energy Technology Data Exchange (ETDEWEB)

    Benmakhlouf, H; Andreo, P [Department of Medical Physics, Karolinska University Hospital, Stockholm and Department of Physics, Medical Radiation Physics, Stockholm University (Sweden)

    2015-06-15

    Purpose: To investigate the influence of photon field size on the electron and photon fluence spectra in the active volume of small field detectors. Methods: The PENELOPE MC system based usercode PenEasy was used to calculate the material influence on the spectra by scoring the differential fluence in inserts of silicon, carbon, phosphorus and aluminium having 3 mm diameter and height. The spectra were then calculated inside the active volume of eleven detectors (ion chambers and solid-state detectors) whose geometry was simulated with great detail. The inserts/detectors were placed at 10 cm depth in a 30 cm x 30 cm x 30 cm water phantom and irradiated with 2.5 MeV photons and Varian Clinac 6 MV beams of small, medium and large size. Results: For all configurations, photon spectra in the scoring volume were similar to that in a small water volume except for additional characteristic x-ray peaks resulting from the material itself and from the materials surrounding the detectors (i.e. high-Z shielding the silicon). Electron fluence calculated in the inserts were up to 60% larger than in water; the difference increased with material density and decreasing field size. MC-calculated doses were compared to analytically determined collision kerma and restricted cema (cut-off=15keV). For the inserts, with large and medium fields K-col agreed with MC-dose, but K-col overestimated the dose for small fields due to lack of lateral CPE. For the detectors, up to 15% differences between K-col and the MC-dose were found. For all configurations the C-delta and MC-dose agreed within ±2%. Conclusion: The most relevant findings were that shielding affects substantially the photon spectra and material conditions the electron spectra, their field size dependence varying with the geometry configuration. These affect the values of factors entering into relative dosimetry.

  13. Imaging of small amounts of pleural fluid. Part one - small pleural effusions

    International Nuclear Information System (INIS)

    Kocijancic, I.

    2005-01-01

    Background. Small pleural effusions are not readily identified on conventional radiographic views of the chest, but may be an important finding, sometimes leading, via thoracocentesis, to a definitive diagnosis of pleural carcinomatosis, infection or transudate. A small meniscus sign and a medial displacement of the costophrenic angle are the only subtle signs of small accumulations of fluid on posteroanterior chest X-rays. On lateral views the finding of a small meniscus sign in the posterior costophrenic angle is the sign of small pleural effusion. Conclusions. Lateral decubitus chest radiographs were used for many years for the diagnosis of small pleural effusions. In last decades ultrasonography of pleural space becomes a leading real-time method for demonstrating small pleural effusions. (author)

  14. Iodine-131 imaging using 284 keV photons with a small animal CZT-SPECT system dedicated to low-medium-energy photon detection.

    Science.gov (United States)

    Kojima, Akihiro; Gotoh, Kumiko; Shimamoto, Masako; Hasegawa, Koki; Okada, Seiji

    2016-02-01

    Iodine-131 is widely used for radionuclide therapy because of its β-particle and for diagnostic imaging employing its principal gamma ray. Since that principal gamma ray has the relatively high energy of 364 keV, small animal single-photon emission computed tomography (SPECT) imaging systems may be required to possess the ability to image such higher energy photons. The aim of this study was to investigate the possibility of imaging I-131 using its 284 keV photons instead of its 364 keV photons in a small animal SPECT imaging system dedicated to the detection of low-medium-energy photons (below 300 keV). The imaging system used was a commercially available preclinical SPECT instrument with CZT detectors that was equipped with multi-pinhole collimators and was accompanied by a CT imager. An energy window for I-131 imaging was set to a photopeak of 284 keV with a low abundance compared with 364 keV photons. Small line sources and two mice, one of each of two types, that were injected with NaI-131 were scanned. Although higher counts occurred at the peripheral region of the reconstructed images due to the collimator penetration by the 364 keV photons, the shape of the small line sources could be well visualized. The measured spatial resolution was relatively poor (~1.9 mm for full width at half maximum and ~3.9 mm for full width at tenth maximum). However, a good linear correlation between SPECT values and the level of I-131 radioactivity was observed. Furthermore, the uptake of NaI-131 to the thyroid gland for the two mice was clearly identified in the 3D-SPECT image fused with the X-ray CT image. We conclude that the use of an energy window set on the photopeak of 284 keV and the multi-pinhole collimator may permit I-131 imaging for a preclinical CZT-SPECT system that does not have the ability to acquire images using the 364 keV photons.

  15. Field configurations for small deviations of the integral filling factors in IQHE

    International Nuclear Information System (INIS)

    Cabo, A.; Castineiras, J.; Gonzalez, R.; Penaranda, S.

    1990-07-01

    A numerical solution of the effective Maxwell equations of the IQHE is presented. It corresponds to inhomogeneous electromagnetic field distributions appearing after a small constant magnetic field is added to a 2D-electron gas sheet when the density exactly fills an integral number of Landau levels. It follows that the Chern-Simons terms of the Maxwell equation transform the applied magnetic field into an equivalent homogeneous charge density. The numerical value of this density is exactly the one which is needed to furnish complete filling at the new value of the total magnetic field. The system then reacts tending to screen the effective charge density by removing charge from the sample edges. It is interesting that for the selected parameter values here, reflecting the current experimental situations, the system response is able to approximately establish an integral filling factor in the central portion of the sheet. Then, at least a small plateau is predicted to occur in pure samples at zero temperature. It also follows that the current distribution is unsymmetric under the inversion, as opposed to the configuration associated to a flow of a net Hall current at integral filling factors. (author). 8 refs, 4 figs

  16. Special issue dedicated to Professor Johann M. Schepers

    Directory of Open Access Journals (Sweden)

    Gideon P De Bruin

    2006-10-01

    Full Text Available It is a great pleasure for me to have been associated with this special issue of the SA Journal of Industrial Psychology dedicated to Professor Johann M. Schepers. The purpose of the special issue is to honour Professor Schepers for his contributions to the development of Psychology and Industrial Psychology as empirical fields of study in South Africa. The contributors have worked with Professor Schepers as students or colleagues and share his academic interests. The articles reflect his areas of interest and employ analytic techniques taught and championed by him. We are grateful to Professor Schepers for his cooperation throughout this project. Thanks are due to all the contributors and referees.

  17. Modeling and characterization of a SPECT system with pinhole collimation for the imaging of small animals

    International Nuclear Information System (INIS)

    Auer, Benjamin

    2017-01-01

    My thesis work focuses on the development of several quantitative reconstruction methods dedicated to small animal Single Photon Emission Computed Tomography (SPECT). The latter is based on modeling the acquisition process of the 4-heads pinhole SPECT system available at Institut Pluridisciplinaire Hubert Curien (IPHC) and fully integrated to the AMISSA platform using Monte Carlo simulations. The system matrix approach, combined with the OS-EM iterative reconstruction algorithm, enabled to characterize the system performances and to compare it to the state of the art. Sensitivity of about 0,027% in the center of the field of view associated to a tomographic spatial resolution of 0, 875 ± 0, 025 mm were obtained. The major drawbacks of Monte Carlo methods led us to develop an efficient and simplified modeling of the physical effects occurring in the subject. My approach based on a system matrix decomposition, associated to a scatter pre-calculated database method, demonstrated an acceptable time for a daily imaging subject follow-up (∼ 1 h), leading to a personalized imaging reconstruction (article accepted). The inherent approximations of the scatter pre-calculated approach (first order scattering modeling and segmented emission) have a moderate impact on the recovery coefficients results, nevertheless a correction of about 10% was achieved. (author) [fr

  18. A meta-analysis of perceptual and cognitive functions involved in useful-field-of-view test performance

    NARCIS (Netherlands)

    Woutersen, K.; Guadron Palma, L.M.; Berg, A.V. van den; Boonstra, F.N.; Theelen, T.; Goossens, J.

    2017-01-01

    The useful-field-of-view (UFOV) test measures the amount of information someone can extract from a visual scene in one glance. Its scores show relatively strong relationships with everyday activities. The UFOV test consists of three computer tests, suggested to measure processing speed and central

  19. Comprehensive small animal imaging strategies on a clinical 3 T dedicated head MR-scanner; adapted methods and sequence protocols in CNS pathologies.

    Directory of Open Access Journals (Sweden)

    Deepu R Pillai

    sequence protocol modifications resulted in images of high diagnostic quality. These results prove that lack of dedicated animal scanners shouldn't discourage conventional small animal imaging studies.

  20. Comprehensive Small Animal Imaging Strategies on a Clinical 3 T Dedicated Head MR-Scanner; Adapted Methods and Sequence Protocols in CNS Pathologies

    Science.gov (United States)

    Pillai, Deepu R.; Heidemann, Robin M.; Lanz, Titus; Dittmar, Michael S.; Sandner, Beatrice; Beier, Christoph P.; Weidner, Norbert; Greenlee, Mark W.; Schuierer, Gerhard; Bogdahn, Ulrich; Schlachetzki, Felix

    2011-01-01

    modifications resulted in images of high diagnostic quality. These results prove that lack of dedicated animal scanners shouldn't discourage conventional small animal imaging studies. PMID:21326876

  1. Static properties of small Josephson tunnel junctions in a transverse magnetic field

    DEFF Research Database (Denmark)

    Monaco, R.; Aarøe, Morten; Mygind, Jesper

    2008-01-01

    The magnetic field distribution in the barrier of small planar Josephson tunnel junctions is numerically simulated in the case when an external magnetic field is applied perpendicular to the barrier plane. The simulations allow for heuristic analytical solutions for the Josephson static phase...... profile from which the dependence of the maximum Josephson current on the applied field amplitude is derived. The most common geometrical configurations are considered and, when possible, the theoretical findings are compared with the experimental data. ©2008 American Institute of Physics...

  2. Clinical evaluation of 2D versus 3D whole-body PET image quality using a dedicated BGO PET scanner

    International Nuclear Information System (INIS)

    Visvikis, D.; Griffiths, D.; Costa, D.C.; Bomanji, J.; Ell, P.J.

    2005-01-01

    Three-dimensional positron emission tomography (3D PET) results in higher system sensitivity, with an associated increase in the detection of scatter and random coincidences. The objective of this work was to compare, from a clinical perspective, 3D and two-dimensional (2D) acquisitions in terms of whole-body (WB) PET image quality with a dedicated BGO PET system. 2D and 3D WB emission acquisitions were carried out in 70 patients. Variable acquisition parameters in terms of time of emission acquisition per axial field of view (aFOV) and slice overlap between sequential aFOVs were used during the 3D acquisitions. 3D and 2D images were reconstructed using FORE+WLS and OSEM respectively. Scatter correction was performed by convolution subtraction and a model-based scatter correction in 2D and 3D respectively. All WB images were attenuation corrected using segmented transmission scans. Images were blindly assessed by three observers for the presence of artefacts, confidence in lesion detection and overall image quality using a scoring system. Statistically significant differences between 2D and 3D image quality were only obtained for 3D emission acquisitions of 3 min. No statistically significant differences were observed for image artefacts or lesion detectability scores. Image quality correlated significantly with patient weight for both modes of operation. Finally, no differences were seen in image artefact scores for the different axial slice overlaps considered, suggesting the use of five slice overlaps in 3D WB acquisitions. 3D WB imaging using a dedicated BGO-based PET scanner offers similar image quality to that obtained in 2D considering similar overall times of acquisitions. (orig.)

  3. Performance of a DOI-encoding small animal PET system with monolithic scintillators

    International Nuclear Information System (INIS)

    Carles, M.; Lerche, Ch.W.; Sánchez, F.; Orero, A.; Moliner, L.; Soriano, A.; Benlloch, J.M.

    2012-01-01

    PET systems designed for specific applications require high resolution and sensitivity instrumentation. In dedicated system design smaller ring diameters and deeper crystals are widely used in order to increase the system sensitivity. However, this design increases the parallax error, which degrades the spatial image resolution gradually from the center to the edge of the field-of-view (FOV). Our group has designed a depth of interaction(DOI)-encoding small animal PET system based on monolithic crystals. In this work we investigate the restoration of radial resolution for transaxially off-center sources using the DOI information provided by our system. For this purpose we have designed a support for point like sources adapted to our system geometry that allows a spatial compression and resolution response study. For different point source radial positions along vertical and horizontal axes of a FOV transaxial plane we compare the results obtained by three methods: without DOI information, with the DOI provided by our system and with the assumption that all the γ-rays interact at half depth of the crystal thickness. Results show an improvement of the mean resolution of 10% with the half thickness assumption and a 16% achieved using the DOI provided by the system. Furthermore, a 10% restoration of the resolution uniformity is obtained using the half depth assumption and an 18% restoration using measured DOI.

  4. Dedicating Fermilab's Collider

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    1986-01-15

    It was a bold move to have a fullscale dedication ceremony for the new proton-antiproton Collider at the Fermilab Tevatron on 13 October, two days before the first collisions were seen. However the particles dutifully behaved as required, and over the following weekend the Collider delivered its goods at a total energy of 1600 GeV, significantly boosting the world record for laboratory collisions.

  5. Nuclab Marcoule: a dedicated waste management and dismantling support laboratory

    International Nuclear Information System (INIS)

    Dugne, Olivier; Bec-Espitalier, Lionel; Rosen, Jeremy

    2014-01-01

    Formerly dedicated to plutonium production support, NucLab was renovated to perform a wide range of analyses for dismantling, plant operation and process development activities mainly at Marcoule but also for external clients. The laboratory is a CEA entity in the Nuclear Energy Division. It provides services to several industrial operators (nuclear processes and power plants) in the fields of analytical chemistry, radioactivity measurements, in situ nuclear measurements, decontamination processes, industrial chemistry processes, and waste treatment. NucLab supports research, production, and dismantling activities in all areas of dismantling operations (authors)

  6. Small mammal use of native warm-season and non-native cool-season grass forage fields

    Science.gov (United States)

    Ryan L Klimstra,; Christopher E Moorman,; Converse, Sarah J.; Royle, J. Andrew; Craig A Harper,

    2015-01-01

    Recent emphasis has been put on establishing native warm-season grasses for forage production because it is thought native warm-season grasses provide higher quality wildlife habitat than do non-native cool-season grasses. However, it is not clear whether native warm-season grass fields provide better resources for small mammals than currently are available in non-native cool-season grass forage production fields. We developed a hierarchical spatially explicit capture-recapture model to compare abundance of hispid cotton rats (Sigmodon hispidus), white-footed mice (Peromyscus leucopus), and house mice (Mus musculus) among 4 hayed non-native cool-season grass fields, 4 hayed native warm-season grass fields, and 4 native warm-season grass-forb ("wildlife") fields managed for wildlife during 2 summer trapping periods in 2009 and 2010 of the western piedmont of North Carolina, USA. Cotton rat abundance estimates were greater in wildlife fields than in native warm-season grass and non-native cool-season grass fields and greater in native warm-season grass fields than in non-native cool-season grass fields. Abundances of white-footed mouse and house mouse populations were lower in wildlife fields than in native warm-season grass and non-native cool-season grass fields, but the abundances were not different between the native warm-season grass and non-native cool-season grass fields. Lack of cover following haying in non-native cool-season grass and native warm-season grass fields likely was the key factor limiting small mammal abundance, especially cotton rats, in forage fields. Retention of vegetation structure in managed forage production systems, either by alternately resting cool-season and warm-season grass forage fields or by leaving unharvested field borders, should provide refugia for small mammals during haying events.

  7. Methodology for creating dedicated machine and algorithm on sunflower counting

    Science.gov (United States)

    Muracciole, Vincent; Plainchault, Patrick; Mannino, Maria-Rosaria; Bertrand, Dominique; Vigouroux, Bertrand

    2007-09-01

    In order to sell grain lots in European countries, seed industries need a government certification. This certification requests purity testing, seed counting in order to quantify specified seed species and other impurities in lots, and germination testing. These analyses are carried out within the framework of international trade according to the methods of the International Seed Testing Association. Presently these different analyses are still achieved manually by skilled operators. Previous works have already shown that seeds can be characterized by around 110 visual features (morphology, colour, texture), and thus have presented several identification algorithms. Until now, most of the works in this domain are computer based. The approach presented in this article is based on the design of dedicated electronic vision machine aimed to identify and sort seeds. This machine is composed of a FPGA (Field Programmable Gate Array), a DSP (Digital Signal Processor) and a PC bearing the GUI (Human Machine Interface) of the system. Its operation relies on the stroboscopic image acquisition of a seed falling in front of a camera. A first machine was designed according to this approach, in order to simulate all the vision chain (image acquisition, feature extraction, identification) under the Matlab environment. In order to perform this task into dedicated hardware, all these algorithms were developed without the use of the Matlab toolbox. The objective of this article is to present a design methodology for a special purpose identification algorithm based on distance between groups into dedicated hardware machine for seed counting.

  8. Partial body irradiation of small laboratory animals with an industrial X-ray tube

    International Nuclear Information System (INIS)

    Frenzel, Thorsten; Kruell, Andreas; Grohmann, Carsten; Schumacher, Udo

    2014-01-01

    Dedicated precise small laboratory animal irradiation sources are needed for basic cancer research and to meet this need expensive high precision radiation devices have been developed. To avoid such expenses a cost efficient way is presented to construct a device for partial body irradiation of small laboratory animals by adding specific components to an industrial X-ray tube. A custom made radiation field tube was added to an industrial 200 kV X-ray tube. A light field display as well as a monitor ionization chamber were implemented. The field size can rapidly be changed by individual inserts of MCP96 that are used for secondary collimation of the beam. Depth dose curves and cross sectional profiles were determined with the use of a custom made water phantom. More components like positioning lasers, a custom made treatment couch, and a commercial isoflurane anesthesia unit were added to complete the system. With the accessories described secondary small field sizes down to 10 by 10 mm 2 (secondary collimator size) could be achieved. The dosimetry of the beam was constructed like those for conventional stereotactical clinical linear accelerators. The water phantom created showed an accuracy of 1 mm and was well suited for all measurements. With the anesthesia unit attached to the custom made treatment couch the system is ideal for the radiation treatment of small laboratory animals like mice. It was feasible to shrink the field size of an industrial X-ray tube from whole animal irradiation to precise partial body irradiation of small laboratory animals. Even smaller secondary collimator sizes than 10 by 10 mm 2 are feasible with adequate secondary collimator inserts. Our custom made water phantom was well suited for the basic dosimetry of the X-ray tube.

  9. Intelligent urban public transportation for accessibility dedicated to people with disabilities.

    Science.gov (United States)

    Zhou, Haiying; Hou, Kun-Mean; Zuo, Decheng; Li, Jian

    2012-01-01

    The traditional urban public transport system generally cannot provide an effective access service for people with disabilities, especially for disabled, wheelchair and blind (DWB) passengers. In this paper, based on advanced information & communication technologies (ICT) and green technologies (GT) concepts, a dedicated public urban transportation service access system named Mobi+ has been introduced, which facilitates the mobility of DWB passengers. The Mobi+ project consists of three subsystems: a wireless communication subsystem, which provides the data exchange and network connection services between buses and stations in the complex urban environments; the bus subsystem, which provides the DWB class detection & bus arrival notification services; and the station subsystem, which implements the urban environmental surveillance & bus auxiliary access services. The Mobi+ card that supports multi-microcontroller multi-transceiver adopts the fault-tolerant component-based hardware architecture, in which the dedicated embedded system software, i.e., operating system micro-kernel and wireless protocol, has been integrated. The dedicated Mobi+ embedded system provides the fault-tolerant resource awareness communication and scheduling mechanism to ensure the reliability in data exchange and service provision. At present, the Mobi+ system has been implemented on the buses and stations of line '2' in the city of Clermont-Ferrand (France). The experiential results show that, on one hand the Mobi+ prototype system reaches the design expectations and provides an effective urban bus access service for people with disabilities; on the other hand the Mobi+ system is easily to deploy in the buses and at bus stations thanks to its low energy consumption and small form factor.

  10. Intelligent Urban Public Transportation for Accessibility Dedicated to People with Disabilities

    Science.gov (United States)

    Zhou, Haiying; Hou, Kun-Mean; Zuo, Decheng; Li, Jian

    2012-01-01

    The traditional urban public transport system generally cannot provide an effective access service for people with disabilities, especially for disabled, wheelchair and blind (DWB) passengers. In this paper, based on advanced information & communication technologies (ICT) and green technologies (GT) concepts, a dedicated public urban transportation service access system named Mobi+ has been introduced, which facilitates the mobility of DWB passengers. The Mobi+ project consists of three subsystems: a wireless communication subsystem, which provides the data exchange and network connection services between buses and stations in the complex urban environments; the bus subsystem, which provides the DWB class detection & bus arrival notification services; and the station subsystem, which implements the urban environmental surveillance & bus auxiliary access services. The Mobi+ card that supports multi-microcontroller multi-transceiver adopts the fault-tolerant component-based hardware architecture, in which the dedicated embedded system software, i.e., operating system micro-kernel and wireless protocol, has been integrated. The dedicated Mobi+ embedded system provides the fault-tolerant resource awareness communication and scheduling mechanism to ensure the reliability in data exchange and service provision. At present, the Mobi+ system has been implemented on the buses and stations of line ‘2’ in the city of Clermont-Ferrand (France). The experiential results show that, on one hand the Mobi+ prototype system reaches the design expectations and provides an effective urban bus access service for people with disabilities; on the other hand the Mobi+ system is easily to deploy in the buses and at bus stations thanks to its low energy consumption and small form factor. PMID:23112622

  11. Intelligent Urban Public Transportation for Accessibility Dedicated to People with Disabilities

    Directory of Open Access Journals (Sweden)

    Jian Li

    2012-08-01

    Full Text Available The traditional urban public transport system generally cannot provide an effective access service for people with disabilities, especially for disabled, wheelchair and blind (DWB passengers. In this paper, based on advanced information & communication technologies (ICT and green technologies (GT concepts, a dedicated public urban transportation service access system named Mobi+ has been introduced, which facilitates the mobility of DWB passengers. The Mobi+ project consists of three subsystems: a wireless communication subsystem, which provides the data exchange and network connection services between buses and stations in the complex urban environments; the bus subsystem, which provides the DWB class detection & bus arrival notification services; and the station subsystem, which implements the urban environmental surveillance & bus auxiliary access services. The Mobi+ card that supports multi-microcontroller multi-transceiver adopts the fault-tolerant component-based hardware architecture, in which the dedicated embedded system software, i.e., operating system micro-kernel and wireless protocol, has been integrated. The dedicated Mobi+ embedded system provides the fault-tolerant resource awareness communication and scheduling mechanism to ensure the reliability in data exchange and service provision. At present, the Mobi+ system has been implemented on the buses and stations of line ‘2’ in the city of Clermont-Ferrand (France. The experiential results show that, on one hand the Mobi+ prototype system reaches the design expectations and provides an effective urban bus access service for people with disabilities; on the other hand the Mobi+ system is easily to deploy in the buses and at bus stations thanks to its low energy consumption and small form factor.

  12. Monte Carlo study for designing a dedicated “D”-shaped collimator used in the external beam radiotherapy of retinoblastoma patients

    Energy Technology Data Exchange (ETDEWEB)

    Mayorga, P. A. [FISRAD S.A.S., CR 64 A No. 22 - 41, Bogotá D C, Colombia and Departamento de Física Atómica, Molecular y Nuclear, Universidad de Granada, E-18071 Granada (Spain); Brualla, L.; Sauerwein, W. [NCTeam, Strahlenklinik, Universitätsklinikum Essen, Hufelandstraße 55, D-45122 Essen (Germany); Lallena, A. M., E-mail: lallena@ugr.es [Departamento de Física Atómica, Molecular y Nuclear, Universidad de Granada, E-18071 Granada (Spain)

    2014-01-15

    Purpose: Retinoblastoma is the most common intraocular malignancy in the early childhood. Patients treated with external beam radiotherapy respond very well to the treatment. However, owing to the genotype of children suffering hereditary retinoblastoma, the risk of secondary radio-induced malignancies is high. The University Hospital of Essen has successfully treated these patients on a daily basis during nearly 30 years using a dedicated “D”-shaped collimator. The use of this collimator that delivers a highly conformed small radiation field, gives very good results in the control of the primary tumor as well as in preserving visual function, while it avoids the devastating side effects of deformation of midface bones. The purpose of the present paper is to propose a modified version of the “D”-shaped collimator that reduces even further the irradiation field with the scope to reduce as well the risk of radio-induced secondary malignancies. Concurrently, the new dedicated “D”-shaped collimator must be easier to build and at the same time produces dose distributions that only differ on the field size with respect to the dose distributions obtained by the current collimator in use. The scope of the former requirement is to facilitate the employment of the authors' irradiation technique both at the authors' and at other hospitals. The fulfillment of the latter allows the authors to continue using the clinical experience gained in more than 30 years. Methods: The Monte Carlo codePENELOPE was used to study the effect that the different structural elements of the dedicated “D”-shaped collimator have on the absorbed dose distribution. To perform this study, the radiation transport through a Varian Clinac 2100 C/D operating at 6 MV was simulated in order to tally phase-space files which were then used as radiation sources to simulate the considered collimators and the subsequent dose distributions. With the knowledge gained in that study, a new

  13. A compact proton synchrotron with combined-function lattice dedicated for cancer therapy

    CERN Document Server

    Morita, A; Inoue, M; Shirai, T; Iwashita, Y; Hiramoto, K; Katane, M; Tadokoro, M; Nishi, M; Umezawa, M

    1999-01-01

    A compact proton synchrotron with combined function lattice has been designed as a dedicated machine for cancer therapy because of its merits of easy operation and low construction cost. The lattice has a six-fold symmetry and its radius of curvature and circumference are 1.9 m and 23.9 m, respectively. For the purpose of establishing a good reference design, we have constructed a model magnet based on the three-dimensional magnetic field calculation. A magnetic field measurement has been performed with use of a three-dimensional Hall- probe. In the present paper, the results of these developments is presented together with the outline of the reference design. (3 refs) .

  14. Dosimetry of small electron fields shaped by lead

    International Nuclear Information System (INIS)

    Perez, M.; Hill, R.; Whitaker, M.; Greig, L.; West, M.; Jones, L.

    2000-01-01

    Full text: Electron fields can be used to treat superficial cancers. Field shaping can be achieved by placing lead on the patient surface to minimise the dose to surrounding areas and may improve beam penumbra compared to using standard applicators. However, significant dosimetry changes under high density material edges for electron fields have been reported (W Pohlit and KH Manegold, cited in The Physics of Radiation Therapy, P.M. Khan, 1994). This project evaluated the dosimetry of small dimension electron fields shaped with lead placed on the surface. Comparisons were made between circular lead cutouts (3 and 5cm diameters) and an open electron applicator (5cm diameter). For each of these fields depth doses and profiles were measured using a diode detector in a water phantom, and isodoses were measured using X-Omat film sandwiched within a Solid water phantom. Output factors were measured in the Solid water using a Markus parallel plate ionisation chamber. The effect of the lead thickness on the profiles and output was quantified and the thickness used for the final measurements selected so as to give less than 5% transmission of the primary dose. Penumbral widths for 6MeV and 8MeV using the lead cutouts showed distinct differences compared with the open applicator. At depths of the 90% relative dose the profiles for lead shaped fields showed tighter penumbra widths by an average of 2 mm. This became more pronounced nearer the surface where, at 2mm depth, the difference in penumbral widths was an average of 4mm. The 3cm lead cutouts showed surface dose increases of 6% and 9% for 6MeV and 8 MeV respectively. Depth dose parameters (D max and R 90 ) varied by no more than 2mm between the lead cutouts and the open applicator measurements. Lead can be used to shape electron fields for radiotherapy treatments. Depth dose characteristics do not vary significantly with a 5 cm circular applicator. The penumbral width indicates less isodose spread for the lead cutout

  15. Dedicated auxiliary power units for Hybrid Electric Vehicles

    NARCIS (Netherlands)

    Mourad, S.; Weijer, C.J.T. van de

    1998-01-01

    The use of a dedicated auxiliary power unit is essential to utilize the potential that hybrid vehicles offer for efficient and ultra-clean transportation. An example of a hybrid project at the TNO Road-Vehicles Research Institute shows the development and the results of a dedicated auxiliary power

  16. Field of view of limitations in see-through HMD using geometric waveguides.

    Science.gov (United States)

    DeHoog, Edward; Holmstedt, Jason; Aye, Tin

    2016-08-01

    Geometric waveguides are being integrated into head-mounted display (HMD) systems, where having see-through capability in a compact, lightweight form factor is required. We developed methods for determining the field of view (FOV) of such waveguide HMD systems and have analytically derived the FOV for waveguides using planar and curved geometries. By using real ray-tracing methods, we are able to show how the geometry and index of refraction of the waveguide, as well as the properties of the coupling optics, impact the FOV. Use of this analysis allows one to determine the maximum theoretical FOV of a planar or curved waveguide-based system.

  17. High dose per fraction dosimetry of small fields with Gafchromic EBT2 film

    International Nuclear Information System (INIS)

    Hardcastle, Nicholas; Basavatia, Amar; Bayliss, Adam; Tome, Wolfgang A.

    2011-01-01

    Purpose: Small field dosimetry is prone to uncertainties due to the lack of electronic equilibrium and the use of the correct detector size relative to the field size measured. It also exhibits higher sensitivity to setup errors as well as large variation in output with field size and shape. Radiochromic film is an attractive method for reference dosimetry in small fields due to its ability to provide 2D dose measurements while having minimal impact on the dose distribution. Gafchromic EBT2 has a dose range of up to 40 Gy; therefore, it could potentially be useful for high dose reference dosimetry with high spatial resolution. This is a requirement in stereotactic radiosurgery deliveries, which deliver high doses per fraction to small targets. Methods: Targets of 4 mm and 12 mm diameters were treated to a minimum peripheral dose of 21 Gy prescribed to 80% of the maximum dose in one fraction. Target doses were measured with EBT2 film (both targets) and an ion chamber (12 mm target only). Measured doses were compared with planned dose distributions using profiles through the target and minimum peripheral dose coverage. Results: The measured target doses and isodose coverage agreed with the planned dose within ±1 standard deviation of three measurements, which were 2.13% and 2.5% for the 4 mm and 12 mm targets, respectively. Conclusions: EBT2 film is a feasible dosimeter for high dose per fraction reference 2D dosimetry.

  18. Integrated ultrasound and gamma imaging probe for medical diagnosis

    International Nuclear Information System (INIS)

    Pani, R.; Pellegrini, R.; Cinti, M. N.; Polito, C.; Orlandi, C.; Fabbri, A.; Vincentis, G. De

    2016-01-01

    In the last few years, integrated multi-modality systems have been developed, aimed at improving the accuracy of medical diagnosis correlating information from different imaging techniques. In this contest, a novel dual modality probe is proposed, based on an ultrasound detector integrated with a small field of view single photon emission gamma camera. The probe, dedicated to visualize small organs or tissues located at short depths, performs dual modality images and permits to correlate morphological and functional information. The small field of view gamma camera consists of a continuous NaI:Tl scintillation crystal coupled with two multi-anode photomultiplier tubes. Both detectors were characterized in terms of position linearity and spatial resolution performances in order to guarantee the spatial correspondence between the ultrasound and the gamma images. Finally, dual-modality images of custom phantoms are obtained highlighting the good co-registration between ultrasound and gamma images, in terms of geometry and image processing, as a consequence of calibration procedures

  19. Full-field x-ray nano-imaging at SSRF

    Science.gov (United States)

    Deng, Biao; Ren, Yuqi; Wang, Yudan; Du, Guohao; Xie, Honglan; Xiao, Tiqiao

    2013-09-01

    Full field X-ray nano-imaging focusing on material science is under developing at SSRF. A dedicated full field X-ray nano-imaging beamline based on bending magnet will be built in the SSRF phase-II project. The beamline aims at the 3D imaging of the nano-scale inner structures. The photon energy range is of 5-14keV. The design goals with the field of view (FOV) of 20μm and a spatial resolution of 20nm are proposed at 8 keV, taking a Fresnel zone plate (FZP) with outermost zone width of 25 nm. Futhermore, an X-ray nano-imaging microscope is under developing at the SSRF BL13W beamline, in which a larger FOV will be emphasized. This microscope is based on a beam shaper and a zone plate using both absorption contrast and Zernike phase contrast, with the optimized energy set to 10keV. The detailed design and the progress of the project will be introduced.

  20. Energy Secretary Dedicates ESIF at NREL | News | NREL

    Science.gov (United States)

    3 » Energy Secretary Dedicates ESIF at NREL Energy Secretary Dedicates ESIF at NREL September 18 prey. Enlarge image Energy Secretary Ernest Moniz (center) joins NREL Director Dan Arvizu (left) and newest Energy Department supercomputer. The high performance computer inside NREL's new Energy Systems

  1. Small animal MRI: clinical MRI as an interface to basic biomedical research

    International Nuclear Information System (INIS)

    Pinkernelle, J.G.; Stelter, L.; Hamm, B.; Teichgraeber, U.

    2008-01-01

    The demand for highly resolved small animal MRI for the purpose of biomedical research has increased constantly. Dedicated small animal MRI scanners working at ultra high field strengths from 4.7 to 7.0 T and even above are MRI at its best. However, using high resolution RF coils in clinical scanners up to 3.0 T, small animal MRI can achieve highly resolved images showing excellent tissue contrast. In fact, in abundant experimental studies, clinical MRI is used for small animal imaging. Mostly clinical RF coils in the single-loop design are applied. In addition, custom-built RF coils and even gradient inserts are used in a clinical scanner. For the reduction of moving artifacts, special MRI-compatible animal ECG und respiration devices are available. In conclusion, clinical devices offer broad availability, are less expense in combination with good imaging performance and provide a translational nature of imaging results. (orig.)

  2. The Oxford SWIFT integral field spectrograph

    Science.gov (United States)

    Thatte, Niranjan; Tecza, Matthias; Clarke, Fraser; Goodsall, Timothy; Lynn, James; Freeman, David; Davies, Roger L.

    2006-06-01

    We present the design of the Oxford SWIFT integral field spectrograph, a dedicated I and z band instrument (0.65μm micron - 1.0μm micron at R~4000), designed to be used in conjunction with the Palomar laser guide star adaptive optics system (PALAO, and its planned upgrade PALM-3000). It builds on two recent developments (i) the improved ability of second generation adaptive optics systems to correct for atmospheric turbulence at wavelengths less than or equal to 1μm micron, and (ii) the availability of CCD array detectors with high quantum efficiency at very red wavelengths (close to the silicon band edge). Combining these with a state-of-the-art integral field unit design using an all-glass image slicer, SWIFT's design provides very high throughput and low scattered light. SWIFT simultaneously provides spectra of ~4000 spatial elements, arranged in a rectangular field-of-view of 44 × 89 pixels. It has three on-the-fly selectable pixel scales of 0.24", 0.16" and 0.08'. First light is expected in spring 2008.

  3. Mapping informal small-scale mining features in a data-sparse tropical environment with a small UAS

    Science.gov (United States)

    Chirico, Peter G.; Dewitt, Jessica D.

    2017-01-01

    This study evaluates the use of a small unmanned aerial system (UAS) to collect imagery over artisanal mining sites in West Africa. The purpose of this study is to consider how very high-resolution imagery and digital surface models (DSMs) derived from structure-from-motion (SfM) photogrammetric techniques from a small UAS can fill the gap in geospatial data collection between satellite imagery and data gathered during field work to map and monitor informal mining sites in tropical environments. The study compares both wide-angle and narrow field of view camera systems in the collection and analysis of high-resolution orthoimages and DSMs of artisanal mining pits. The results of the study indicate that UAS imagery and SfM photogrammetric techniques permit DSMs to be produced with a high degree of precision and relative accuracy, but highlight the challenges of mapping small artisanal mining pits in remote and data sparse terrain.

  4. Small-scale field-aligned currents observed by the AKEBONO (EXOS-D) satellite

    International Nuclear Information System (INIS)

    Fukunishi, H.; Oya, H.; Kokubun, S.; Tohyama, F.; Mukai, T.; Fujii, R.

    1991-01-01

    The EXOS-D fluxgate magnetometer data obtained at 3,000-10,000 km altitude have shown that small-scale field-aligned currents always exist in large-scale region 1, region 2, cusp and polar cap current systems. Assuming that these small-scale field-aligned currents have current sheet structure, the width of current sheet is estimated to be 5-20 km at ionospheric altitude. By comparing the magnetometer data with charged particle and high frequency plasma wave data simultaneously obtained from EXOS-D, it is found that small-scale currents have one-to-one correspondence with localized electron precipitation events characterized by flux enhancement over a wide energy range from 10 eV to several keV and broadband electrostatic bursts occasionally extending above local plasma frequencies or electron cyclotron frequencies

  5. Special features in choosing a development procedure for deep gas condensate fields with small reserves

    Energy Technology Data Exchange (ETDEWEB)

    Rassokhin, G V; Soshnin, N M

    1971-01-01

    In planning the development and production schedule for fields with small gas-condensate reserves, the following factors need to be considered: capital investment per unit of production, value of produced gas, ultimate recovered reserves, geological structure of the field, depth of well, heterogeneity of producing sands, etc. The importance of such factors is discussed and it is shown that for small fields, the parameter of minimum net expense cannot be used as a planning tool. Both geological and economic factors must be included in field development.

  6. Design of the dipole and quadrupole magnets of the dedicated proton synchrotron for hadron therapy

    International Nuclear Information System (INIS)

    Kukarnikov, S.I.; Makoveev, V.K.; Minashkin, V.F.; Molodozhentsev, A.Yu.; Shevtsov, V.F.; Sidorov, G.I.

    1998-01-01

    The 2D-calculation results of magnetic elements of the PRAMES (Prague Medical Synchrotron) are presented. This machine is a dedicated accelerator for cancer therapy. The output energy of the beam should be variable in the range 60-220 MeV. The maximum magnetic field of the dipole magnet should be 1.2 T, the maximum magnetic field ramp - less than 8 T/s. The focusing structure of the proton synchrotron consists of 8 dipole and 18 quadrupole magnets. All magnets are laminated to minimize leakage currents. The dipoles are parallel-edge, H-type magnets. The field uniformity should be of the order of ± 1 x 10 -4 in the working area (± 63 mm and ± 27 mm in the horizontal and vertical planes, respectively). The maximum magnetic field on the pole of the quadrupole lenses should be less than 1 T. The gradient uniformity of quadrupole magnets in the working region should be less than ± 3.5 x 10 -4

  7. Screening small-molecule compound microarrays for protein ligands without fluorescence labeling with a high-throughput scanning microscope.

    Science.gov (United States)

    Fei, Yiyan; Landry, James P; Sun, Yungshin; Zhu, Xiangdong; Wang, Xiaobing; Luo, Juntao; Wu, Chun-Yi; Lam, Kit S

    2010-01-01

    We describe a high-throughput scanning optical microscope for detecting small-molecule compound microarrays on functionalized glass slides. It is based on measurements of oblique-incidence reflectivity difference and employs a combination of a y-scan galvometer mirror and an x-scan translation stage with an effective field of view of 2 cm x 4 cm. Such a field of view can accommodate a printed small-molecule compound microarray with as many as 10,000 to 20,000 targets. The scanning microscope is capable of measuring kinetics as well as endpoints of protein-ligand reactions simultaneously. We present the experimental results on solution-phase protein reactions with small-molecule compound microarrays synthesized from one-bead, one-compound combinatorial chemistry and immobilized on a streptavidin-functionalized glass slide.

  8. Field emission characteristics of a small number of carbon fiber emitters

    Directory of Open Access Journals (Sweden)

    Wilkin W. Tang

    2016-09-01

    Full Text Available This paper reports an experiment that studies the emission characteristics of small number of field emitters. The experiment consists of nine carbon fibers in a square configuration. Experimental results show that the emission characteristics depend strongly on the separation between each emitter, providing evidence of the electric field screening effects. Our results indicate that as the separation between the emitters decreases, the emission current for a given voltage also decreases. The authors compare the experimental results to four carbon fiber emitters in a linear and square configurations as well as to two carbon fiber emitters in a paired array. Voltage-current traces show that the turn-on voltage is always larger for the nine carbon fiber emitters as compared to the two and four emitters in linear configurations, and approximately identical to the four emitters in a square configuration. The observations and analysis reported here, based on Fowler-Nordheim field emission theory, suggest the electric field screening effect depends critically on the number of emitters, the separation between them, and their overall geometric configuration.

  9. Survey VS audit by using method 2 to dedicate commercial grade services

    International Nuclear Information System (INIS)

    Martinez ayucar, F. J.

    2014-01-01

    Since the start of the commercial grade dedications, both 10CFR21 and EPRI documents, plus the dedication of commercial grade components, and the stage of commercial grade dedication of the services contemplated. And recently the NRC through various communications and answers trafficking among other issues the commercial grade dedication service. The NRC has detected repeatedly incorrect application of the survey as a method of commercial grade dedication and instead has done an audit of the program elements of commercial quality. (Author)

  10. Clear-PEM: A PET imaging system dedicated to breast cancer diagnostics

    CERN Document Server

    Abreu, M C; Albuquerque, E; Almeida, F G; Almeida, P; Amaral, P; Auffray, Etiennette; Bento, P; Bruyndonckx, P; Bugalho, R; Carriço, B; Cordeiro, H; Ferreira, M; Ferreira, N C; Gonçalves, F; Lecoq, Paul; Leong, C; Lopes, F; Lousã, P; Luyten, J; Martins, M V; Matela, N; Rato-Mendes, P; Moura, R; Nobre, J; Oliveira, N; Ortigão, C; Peralta, L; Rego, J; Ribeiro, R; Rodrigues, P; Santos, A I; Silva, J C; Silva, M M; Tavernier, Stefaan; Teixeira, I C; Texeira, J P; Trindade, A; Trummer, Julia; Varela, J

    2007-01-01

    The Clear-PEM scanner for positron emission mammography under development is described. The detector is based on pixelized LYSO crystals optically coupled to avalanche photodiodes and readout by a fast low-noise electronic system. A dedicated digital trigger (TGR) and data acquisition (DAQ) system is used for on-line selection of coincidence events with high efficiency, large bandwidth and small dead-time. A specialized gantry allows to perform exams of the breast and of the axilla. In this paper we present results of the measurement of detector modules that integrate the system under construction as well as the imaging performance estimated from Monte Carlo simulated data.

  11. One-inch field of view imaging probe for breast cancer sentinel node location

    International Nuclear Information System (INIS)

    D'Errico, Giovanni; Scafe, Raffaele; Soluri, Alessandro; Schiaratura, Alfiero; Maria Mangano, Anna; David, Vincenzo; Scopinaro, Francesco

    2003-01-01

    The already reported 1-in. 2 field of view mini gamma camera known since 1998 with the name of Imaging Probe (IP), has been used for sentinel node localization by a medical equipe that, though trained by the group of nuclear physicians of the University 'La Sapienza' who first conceived and used this detector, has used IP in its own Hospital to: (1) gain experience for future use during operations--a cooperative work on IP radio guided orthopaedic operations has already started working, and (2) to start with IP multicenter trials. In six patients with breast cancer, who underwent lymphoscintigraphy for sentinel node biopsy, sentinel node was checked and located with IP and non-imaging Neoprobe 2000 CdTe (Zn) probe, independent of location by means of large field of view Anger camera. Operators who used Neoprobe and IP were blinded to each other and not aware of the results of Anger camera imaging. Anger camera, as well as IP and neoprobe detected 7 nodes in 6 pts. Detection time was 2', 06'' SD 26'' with IP and 2', 18'' SD 47'' with neoprobe 2000. The most difficult to find node required 2 min and 56 s--inside sd--for IP detection and 3 min and 45 s with neoprobe. Subjective impression of being sure of having detected sentinel node was: absolutely sure on 7/7 nodes with IP and on 5/7 nodes with neoprobe

  12. Wide field of view CT and acromioclavicular joint instability: A technical innovation.

    Science.gov (United States)

    Dyer, David R; Troupis, John M; Kamali Moaveni, Afshin

    2015-06-01

    A 21-year-old female with a traumatic shoulder injury is investigated and managed for symptoms relating to this injury. Pathology at the acromioclavicular joint is detected clinically; however, clinical examination and multiple imaging modalities do not reach a unified diagnosis on the grading of this acromioclavicular joint injury. When management appropriate to that suggested injury grading fail to help the patient's symptoms, further investigation methods were utilised. Wide field of view, dynamic CT (4D CT) is conducted on the patient's affected shoulder using a 320 × 0.5 mm detector multislice CT. Scans were conducted with a static table as the patient completed three movements of the affected shoulder. Capturing multiple data sets per second over a z-axis of 16 cm, measurements of the acromioclavicular joint were made, to show dynamic changes at the joint. Acromioclavicular (AC) joint translations were witnessed in three planes (a previously unrecognised pathology in the grading of acromioclavicular joint injuries). Translation in multiple planes was also not evident on careful clinical examination of this patient. AC joint width, anterior-posterior translation, superior-inferior translation and coracoclavicular width were measured with planar reconstructions while volume-rendered images and dynamic sequences aiding visual understanding of the pathology. Wide field of view dynamic CT (4D CT) is an accurate and quick modality to diagnose complex acromioclavicular joint injury. It provides dynamic information that no other modality can; 4D CT shows future benefits for clinical approach to diagnosis and management of acromioclavicular joint injury, and other musculoskeletal pathologies. © 2015 The Royal Australian and New Zealand College of Radiologists.

  13. Views of Women's Sexuality and Violence Against Women in Turkey: A Cross-Sectional Investigation Among University Students.

    Science.gov (United States)

    Gursoy, Elif; McCool, William F; Sahinoglu, Serap; Yavuz Genc, Yasemin

    2016-03-01

    This study explored Turkish university students' views of women-related issues--gender roles, sexuality, and violence against women. A cross-sectional study was conducted with 605 students--337 females and 268 males--at Ankara University, Turkey. A survey exploring students' views of female sexuality and violence was used. Comparisons of responses were made among groups based on sex, year of study at the university, and field of study at the university. Three relevant findings were found: male students had more traditional, nonegalitarian approaches toward women's issues than female students; educational levels and fields of study did not significantly influence students' views of women; and a small percentage of students approve of violence against women. These results show that patriarchal values in Turkish society influence the formation of students' opinions, and university education alone cannot affect everyone's views of gender roles, women's sexuality, and violence against women. © The Author(s) 2014.

  14. SU-F-T-577: Comparison of Small Field Dosimetry Measurements in Fields Shaped with Conical Applicators On Two Different Accelerating Systems

    Energy Technology Data Exchange (ETDEWEB)

    Muir, B; McEwen, M [National Research Council, Ottawa, ON (Canada); Belec, J; Vandervoort, E [Ottawa Hospital General Campus, Ottawa, ON (Canada); Christiansen, E [Carleton University, Ottawa, ON (Canada)

    2016-06-15

    Purpose: To investigate small field dosimetry measurements and associated uncertainties when conical applicators are used to shape treatment fields from two different accelerating systems. Methods: Output factor measurements are made in water in beams from the CyberKnife radiosurgery system, which uses conical applicators to shape fields from a (flattening filter-free) 6 MV beam, and in a 6 MV beam from the Elekta Precise linear accelerator (with flattening filter) with BrainLab external conical applicators fitted to shape the field. The measurements use various detectors: (i) an Exradin A16 ion chamber, (ii) two Exradin W1 plastic scintillation detectors, (iii) a Sun Nuclear Edge diode, and (iv) two PTW microDiamond synthetic diamond detectors. Profiles are used for accurate detector positioning and to specify field size (FWHM). Output factor measurements are corrected with detector specific correction factors taken from the literature where available and/or from Monte Carlo simulations using the EGSnrc code system. Results: Differences in measurements of up to 1.7% are observed with a given detector type in the same beam (i.e., intra-detector variability). Corrected results from different detectors in the same beam (inter-detector differences) show deviations up to 3 %. Combining data for all detectors and comparing results from the two accelerators results in a 5.9% maximum difference for the smallest field sizes (FWHM=5.2–5.6 mm), well outside the combined uncertainties (∼1% for the smallest beams) and/or differences among detectors. This suggests that the FWHM of a measured profile is not a good specifier to compare results from different small fields with the same nominal energy. Conclusion: Large differences in results for both intra-detector variability and inter-detector differences suggest potentially high uncertainties in detector-specific correction factors. Differences between the results measured in circular fields from different accelerating

  15. Portable waveguide display system with a large field of view by integrating freeform elements and volume holograms.

    Science.gov (United States)

    Han, Jian; Liu, Juan; Yao, Xincheng; Wang, Yongtian

    2015-02-09

    A compact waveguide display system integrating freeform elements and volume holograms is presented here for the first time. The use of freeform elements can broaden the field of view, which limits the applications of a holographic waveguide. An optimized system can achieve a diagonal field of view of 45° when the thickness of the waveguide planar is 3mm. Freeform-elements in-coupler and the volume holograms out-coupler were designed in detail in our study, and the influence of grating configurations on diffraction efficiency was analyzed thoroughly. The off-axis aberrations were well compensated by the in-coupler and the diffraction efficiency of the optimized waveguide display system could reach 87.57%. With integrated design, stability and reliability of this monochromatic display system were achieved and the alignment of the system was easily controlled by the record of the volume holograms, which makes mass production possible.

  16. Fluctuating local field method probed for a description of small classical correlated lattices

    Science.gov (United States)

    Rubtsov, Alexey N.

    2018-05-01

    Thermal-equilibrated finite classical lattices are considered as a minimal model of the systems showing an interplay between low-energy collective fluctuations and single-site degrees of freedom. Standard local field approach, as well as classical limit of the bosonic DMFT method, do not provide a satisfactory description of Ising and Heisenberg small lattices subjected to an external polarizing field. We show that a dramatic improvement can be achieved within a simple approach, in which the local field appears to be a fluctuating quantity related to the low-energy degree(s) of freedom.

  17. Strongly correlated states of a small cold-atom cloud from geometric gauge fields

    International Nuclear Information System (INIS)

    Julia-Diaz, B.; Dagnino, D.; Barberan, N.; Guenter, K. J.; Dalibard, J.; Grass, T.; Lewenstein, M.

    2011-01-01

    Using exact diagonalization for a small system of cold bosonic atoms, we analyze the emergence of strongly correlated states in the presence of an artificial magnetic field. This gauge field is generated by a laser beam that couples two internal atomic states, and it is related to Berry's geometrical phase that emerges when an atom follows adiabatically one of the two eigenstates of the atom-laser coupling. Our approach allows us to go beyond the adiabatic approximation, and to characterize the generalized Laughlin wave functions that appear in the strong magnetic-field limit.

  18. Strongly correlated states of a small cold-atom cloud from geometric gauge fields

    Energy Technology Data Exchange (ETDEWEB)

    Julia-Diaz, B. [Dept. ECM, Facultat de Fisica, U. Barcelona, E-08028 Barcelona (Spain); ICFO-Institut de Ciencies Fotoniques, Parc Mediterrani de la Tecnologia, E-08860 Barcelona (Spain); Dagnino, D.; Barberan, N. [Dept. ECM, Facultat de Fisica, U. Barcelona, E-08028 Barcelona (Spain); Guenter, K. J.; Dalibard, J. [Laboratoire Kastler Brossel, CNRS, UPMC, Ecole Normale Superieure, 24 rue Lhomond, F-75005 Paris (France); Grass, T. [ICFO-Institut de Ciencies Fotoniques, Parc Mediterrani de la Tecnologia, E-08860 Barcelona (Spain); Lewenstein, M. [ICFO-Institut de Ciencies Fotoniques, Parc Mediterrani de la Tecnologia, E-08860 Barcelona (Spain); ICREA-Institucio Catalana de Recerca i Estudis Avancats, E-08010 Barcelona (Spain)

    2011-11-15

    Using exact diagonalization for a small system of cold bosonic atoms, we analyze the emergence of strongly correlated states in the presence of an artificial magnetic field. This gauge field is generated by a laser beam that couples two internal atomic states, and it is related to Berry's geometrical phase that emerges when an atom follows adiabatically one of the two eigenstates of the atom-laser coupling. Our approach allows us to go beyond the adiabatic approximation, and to characterize the generalized Laughlin wave functions that appear in the strong magnetic-field limit.

  19. The AMFEC: a tool for dedications

    International Nuclear Information System (INIS)

    Pastor Escobar, H.; Gomar Vidal, J.

    2014-01-01

    The process of dedication, consists of a series of activities intended to ensure that a component of commercial grade can be used in applications related with the Security at nuclear facilities. However, in one of the steps of essential dedication, is often the problem defined with certain accuracy the most relevant characteristics or critical acceptance of the component characteristics, which through its verification, give by valid the commercial component for security-related use. Due to lack of information, they can sometimes not be identified clearly, and therefore it is necessary to resort to some alternative method that will allow us to define them, the AMFEC (analysis of failure modes, effects and criticality. (Author)

  20. In vivo assessment of muscle fascicle length by extended field-of-view ultrasonography

    DEFF Research Database (Denmark)

    Noorkoiv, M; Stavnsbo, A; Aagaard, Per

    2010-01-01

    The present study examined the reliability and validity of in vivo vastus lateralis (VL) fascicle length (L(f)) assessment by extended field-of-view ultrasonography (EFOV US). Intraexperimenter and intersession reliability of EFOV US were tested. Further, L(f) measured from EFOV US images were...... compared to L(f) measured from static US images (6-cm FOV) where out-of-field fascicle portions were trigonometrically estimated (linear extrapolation). Finally, spatial accuracy of the EFOV technique was assessed by comparing L(f) measured on swine VL by EFOV US to actual measurements from digital...... and by dissective assessment (digital photographs) in isolated swine VL was 0.84% ± 2.6% with an ICC of 0.99 (CI = 0.94-1.00). These results show that EFOV US is a reliable and valid method for the measurement of long muscle fascicle in vivo. Thus EFOV US analysis was proven more accurate for the assessment...

  1. Measurement of flow velocity fields in small vessel-mimic phantoms and vessels of small animals using micro ultrasonic particle image velocimetry (micro-EPIV).

    Science.gov (United States)

    Qian, Ming; Niu, Lili; Wang, Yanping; Jiang, Bo; Jin, Qiaofeng; Jiang, Chunxiang; Zheng, Hairong

    2010-10-21

    Determining a multidimensional velocity field within microscale opaque fluid flows is needed in areas such as microfluidic devices, biofluid mechanics and hemodynamics research in animal studies. The ultrasonic particle image velocimetry (EchoPIV) technique is appropriate for measuring opaque flows by taking advantage of PIV and B-mode ultrasound contrast imaging. However, the use of clinical ultrasound systems for imaging flows in small structures or animals has limitations associated with spatial resolution. This paper reports on the development of a high-resolution EchoPIV technique (termed as micro-EPIV) and its application in measuring flows in small vessel-mimic phantoms and vessels of small animals. Phantom experiments demonstrate the validity of the technique, providing velocity estimates within 4.1% of the analytically derived values with regard to the flows in a small straight vessel-mimic phantom, and velocity estimates within 5.9% of the computationally simulated values with regard to the flows in a small stenotic vessel-mimic phantom. Animal studies concerning arterial and venous flows of living rats and rabbits show that the micro-EPIV-measured peak velocities within several cardiac cycles are about 25% below the values measured by the ultrasonic spectral Doppler technique. The micro-EPIV technique is able to effectively measure the flow fields within microscale opaque fluid flows.

  2. Measurement of flow velocity fields in small vessel-mimic phantoms and vessels of small animals using micro ultrasonic particle image velocimetry (micro-EPIV)

    International Nuclear Information System (INIS)

    Qian Ming; Niu Lili; Jiang Bo; Jin Qiaofeng; Jiang Chunxiang; Zheng Hairong; Wang Yanping

    2010-01-01

    Determining a multidimensional velocity field within microscale opaque fluid flows is needed in areas such as microfluidic devices, biofluid mechanics and hemodynamics research in animal studies. The ultrasonic particle image velocimetry (EchoPIV) technique is appropriate for measuring opaque flows by taking advantage of PIV and B-mode ultrasound contrast imaging. However, the use of clinical ultrasound systems for imaging flows in small structures or animals has limitations associated with spatial resolution. This paper reports on the development of a high-resolution EchoPIV technique (termed as micro-EPIV) and its application in measuring flows in small vessel-mimic phantoms and vessels of small animals. Phantom experiments demonstrate the validity of the technique, providing velocity estimates within 4.1% of the analytically derived values with regard to the flows in a small straight vessel-mimic phantom, and velocity estimates within 5.9% of the computationally simulated values with regard to the flows in a small stenotic vessel-mimic phantom. Animal studies concerning arterial and venous flows of living rats and rabbits show that the micro-EPIV-measured peak velocities within several cardiac cycles are about 25% below the values measured by the ultrasonic spectral Doppler technique. The micro-EPIV technique is able to effectively measure the flow fields within microscale opaque fluid flows.

  3. Development of High-Field Permanent Magnetic Circuits for NMRI/MRI and Imaging on Mice

    Directory of Open Access Journals (Sweden)

    Guangxin Wang

    2016-01-01

    Full Text Available The high-field permanent magnetic circuits of 1.2 T and 1.5 T with novel magnetic focusing and curved-surface correction are developed. The permanent magnetic circuit comprises a magnetic yoke, main magnetic steel, nonspherical curved-surface magnetic poles, plugging magnetic steel, and side magnetic steel. In this work, a novel shimming method is proposed for the effective correction of base magnetic field (B0 inhomogeneities, which is based on passive shimming on the telescope aspheric cutting, grinding, and fine processing technology of the nonspherical curved-surface magnetic poles and active shimming adding higher-order gradient coils. Meanwhile, the magnetic resonance imaging dedicated alloy with high-saturation magnetic field induction intensity and high electrical resistivity is developed, and nonspherical curved-surface magnetic poles which are made of the dedicated alloy have very good anti-eddy-current effect. In addition, the large temperature coefficient problem of permanent magnet can be effectively controlled by using a high quality temperature controller and deuterium external locking technique. Combining our patents such as gradient coil, RF coil, and integration computer software, two kinds of small animal Micro-MRI instruments are developed, by which the high quality MRI images of mice were obtained.

  4. Experimental and numerical study of the flow field around a small car

    Directory of Open Access Journals (Sweden)

    Dobrev Ivan

    2017-01-01

    Full Text Available This paper presents the aerodynamic study of a small car, which participated in Shell Ecomarathon Europe competition in the Urban Concept Hydrogen class. The goal is to understand the flow field around the vehicle. First, the flow is studied numerically using computational aerodynamics. The numerical simulation is carried out by means of CFD Fluent in order to obtain the drag force experienced by the vehicle and also the flow field. Then the flow field around the car is studied in a wind tunnel by means of particle image velocimetry (PIV. The comparison of the flow fields obtained numerically and experimentally shows good correspondence. The obtained results are very helpful for future car development and permit to improve the drag and to obtain a good stability.

  5. Comparison of film dosimetry and Monte Carlo simulations in small field IMRT

    Energy Technology Data Exchange (ETDEWEB)

    Kim, S.R.; Suh, T.S.; Choe, B.Y.; Lee, H.K. [The Catholic Univ., Seoul (Korea, Republic of); Sohn. Jason W. [Washington Univ., St. Louis (United States)

    2002-07-01

    Intensity modulated radiation therapy(IMRT) is a recent useful technique that conforms a high dose to the target volume while restricting dose to the surrounding critical organs. In IMRT, the small size beam let is used for intensity modulation. Thus, dose calculation in small field is very important. But, dose calculation in small field is not accurate in recent RTP system because electronic disequilibrium and the effect of multiple scattering electron are not considered in dose calculation. and therefore, We have evaluated the errors of depth dose and beam profile between measurement data and Monte Carlo simulation. With a homogeneous phantom and two heterogeneous phantoms, A thermoluminescent dosimeter (TLD) and radiochromic films have been selected for dose measurement in 6 MV photon beams. A linear accelerator Varian 2300C (Varian Medical Systems, USA) equipped with a multileaf collimator have been used in dose measurement. The results of simulations using the Monte Carlo systems BEAM/EGS4 (NRC, Canada) to model the beam geometry have been compared with dose measurements. Generally good agreements were found between measurements and dose calculations of Monte Carlo simulation. But some discrepancies were found in this study. Thus further study will be needed to compensate these errors.

  6. Multicenter study for the evaluation of a dedicated biopsy device for MR-guided vacuum biopsy of the breast

    International Nuclear Information System (INIS)

    Perlet, C.; Sittek, H.; Schneider, P.; Reiser, M.; Heinig, A.; Stets, C.; Heywang-Koebrunner, S.H.; Prat, X.; Lamarque, J.; Taourel, P.; Casselman, J.; Baath, L.; Anderson, I.

    2002-01-01

    The purpose of this multicenter study was to determine the accuracy and clinical value of a dedicated breast biopsy system which allows for MR-guided vacuum biopsy (VB) of contrast-enhancing lesions. In five European centers, MR-guided 11-gauge VB was performed on 341 lesions. In 7 cases VB was unsuccessful. This was immediately realized on postinterventional images or direct follow-up combined with histopathology-imaging correlation; thus, a false-negative diagnosis was avoided. Histology of 334 successful biopsies yielded 84 (25%) malignancies, 17 (5%) atypical ductal hyperplasias, and 233 (70%) benign entities. Verification of malignant or borderline lesions included reexcision of the biopsy cavity. Benign histologic biopsy results were verified by retrospective correlation with the pre- and postinterventional MRI and by subsequent follow-up. Our results indicate that MR-guided VB, in combination with the dedicated biopsy coil, offers the possibility to accurately diagnose even very small lesions that can only be visualized or localized by MRI. (orig.)

  7. A lithospheric magnetic field model derived from the Swarm satellite magnetic field measurements

    Science.gov (United States)

    Hulot, G.; Thebault, E.; Vigneron, P.

    2015-12-01

    The Swarm constellation of satellites was launched in November 2013 and has since then delivered high quality scalar and vector magnetic field measurements. A consortium of several research institutions was selected by the European Space Agency (ESA) to provide a number of scientific products which will be made available to the scientific community. Within this framework, specific tools were tailor-made to better extract the magnetic signal emanating from Earth's the lithospheric. These tools rely on the scalar gradient measured by the lower pair of Swarm satellites and rely on a regional modeling scheme that is more sensitive to small spatial scales and weak signals than the standard spherical harmonic modeling. In this presentation, we report on various activities related to data analysis and processing. We assess the efficiency of this dedicated chain for modeling the lithospheric magnetic field using more than one year of measurements, and finally discuss refinements that are continuously implemented in order to further improve the robustness and the spatial resolution of the lithospheric field model.

  8. Determination of low-field critical parameters of superconducting niobium by small-angle neutron diffraction

    International Nuclear Information System (INIS)

    Christen, D.K.; Spooner, S.; Thorel, P.; Kerchner, H.R.

    1977-01-01

    The perfect double-crystal small-angle diffraction technique enables measurement of scattering angles to within 0.3 arc sec. accuracy. At a wavelength of 2.55 A, this provides a resolution of 3 x 10 -6 A -1 in the scattering vector. This technique has been used to study the anisotropic behavior of the critical parameters B 0 and H/sub c1/, characteristic of the first-order magnetic phase transition which occurs in low-kappa type-II superconductors. Magnetic fields were applied parallel to several crystal axes of a large single-crystal sphere of pure niobium, resulting in well-defined flux-line lattices (FLL). Measurement of the FLL cell area in the intermediate mixed state field region gives the equilibrium flux density B 0 , which results from an attractive interaction between fluxoids. In addition, field variation of the scattered neutron intensity allows measurement of the transition field between the mixed state and intermediate mixed state. This transition field is related to the lower critical field H/sub c1/ and enables its determination to a precision 0.2%. Data at T = 4.3 K display a small anisotropic effect of about 2% in B 0 and 1% in H/sub c1/. Although orientation effects of this magnitude are difficult to resolve by bulk measurements, the neutron data are in accord with magnetization data. Observations regarding the temperature dependence of these parameters also will be presented, and comparisons made with current theoretical models

  9. Dedicated Industrial Oilseed Crops as Metabolic Engineering Platforms for Sustainable Industrial Feedstock Production.

    Science.gov (United States)

    Zhu, Li-Hua; Krens, Frans; Smith, Mark A; Li, Xueyuan; Qi, Weicong; van Loo, Eibertus N; Iven, Tim; Feussner, Ivo; Nazarenus, Tara J; Huai, Dongxin; Taylor, David C; Zhou, Xue-Rong; Green, Allan G; Shockey, Jay; Klasson, K Thomas; Mullen, Robert T; Huang, Bangquan; Dyer, John M; Cahoon, Edgar B

    2016-02-26

    Feedstocks for industrial applications ranging from polymers to lubricants are largely derived from petroleum, a non-renewable resource. Vegetable oils with fatty acid structures and storage forms tailored for specific industrial uses offer renewable and potentially sustainable sources of petrochemical-type functionalities. A wide array of industrial vegetable oils can be generated through biotechnology, but will likely require non-commodity oilseed platforms dedicated to specialty oil production for commercial acceptance. Here we show the feasibility of three Brassicaceae oilseeds crambe, camelina, and carinata, none of which are widely cultivated for food use, as hosts for complex metabolic engineering of wax esters for lubricant applications. Lines producing wax esters >20% of total seed oil were generated for each crop and further improved for high temperature oxidative stability by down-regulation of fatty acid polyunsaturation. Field cultivation of optimized wax ester-producing crambe demonstrated commercial utility of these engineered crops and a path for sustainable production of other industrial oils in dedicated specialty oilseeds.

  10. The practical application of scintillation dosimetry in small-field photon-beam radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Burke, Elisa; Poppinga, Daniela; Schoenfeld, Andreas A.; Poppe, Bjoern; Looe, Hui Khee [Oldenburg Univ. (Germany). Univ. Clinic for Medical Radiation Physics; Harder, Dietrich [Goettingen Univ. (Germany). Medical Physics and Biophysics

    2017-07-01

    Plastic scintillation detectors are a new instrument of stereotactic photon-beam dosimetry. The clinical application of the plastic scintillation detector Exradin W1 at the Siemens Artiste and Elekta Synergy accelerators is a matter of current interest. In order to reduce the measurement uncertainty, precautions have to be taken with regard to the geometrical arrangement of the scintillator, the light-guide fiber and the photodiode in the radiation field. To determine the ''Cerenkov light ratio'' CLR with a type A uncertainty below 1%, the Cerenkov calibration procedure for small-field measurements based on the two-channel spectral method was used. Output factors were correctly measured with the W1 for field sizes down to 0.5 x 0.5 cm{sup 2} with a type A uncertainty of 1.8%. Measurements of small field dose profiles and percentage depth dose curves were carried out with the W1 using automated water phantom profile scans, and a type A uncertainty for dose maxima of 1.4% was achieved. The agreement with a synthetic diamond detector (microDiamond, PTW Freiburg) and a plane parallel ionization chamber (Roos chamber, PTW Freiburg) in relative dose measurements was excellent. In oversight of all results, the suitability of the plastic scintillation detector Exradin W1 for clinical dosimetry under stereotactic conditions, in particular the tried and tested procedures for CLR determination, output factor measurement and automated dose profile scans in water phantoms, have been confirmed.

  11. Commercial off-the-shelf software dedication process based on the commercial grade survey of supplier

    International Nuclear Information System (INIS)

    Kim, J. Y.; Lee, J. S.; Chon, S. W.; Lee, G. Y.; Park, J. K.

    2000-01-01

    Commercial Off-The-Shelf(COTS) software dedication process can apply to a combination of methods like the hardware commercial grade item dedication process. In general, these methods are : methods 1(special test and inspection), method 2(commercial grade survey of supplier), method 3(source verification), and method 4(acceptance supplier/item performance record). In this paper, the suggested procedure-oriented dedication process on the basis of method 2 for COTS software is consistent with EPRI/TR-106439 and NUREG/CR-6421 requirements. Additional tailoring policy based on code and standards related to COTS software may be also founded in the suggested commercial software dedication process. Suggested commercial software dedication process has been developed for a commercial I and C software dedication who performs COTS qualification according to the dedication procedure

  12. Resonant Scanning with Large Field of View Reduces Photobleaching and Enhances Fluorescence Yield in STED Microscopy.

    Science.gov (United States)

    Wu, Yong; Wu, Xundong; Lu, Rong; Zhang, Jin; Toro, Ligia; Stefani, Enrico

    2015-10-01

    Photobleaching is a major limitation of superresolution Stimulated Depletion Emission (STED) microscopy. Fast scanning has long been considered an effective means to reduce photobleaching in fluorescence microscopy, but a careful quantitative study of this issue is missing. In this paper, we show that the photobleaching rate in STED microscopy can be slowed down and the fluorescence yield be enhanced by scanning with high speed, enabled by using large field of view in a custom-built resonant-scanning STED microscope. The effect of scanning speed on photobleaching and fluorescence yield is more remarkable at higher levels of depletion laser irradiance, and virtually disappears in conventional confocal microscopy. With ≥6 GW∙cm(-2) depletion irradiance, we were able to extend the fluorophore survival time of Atto 647N and Abberior STAR 635P by ~80% with 8-fold wider field of view. We confirm that STED Photobleaching is primarily caused by the depletion light acting upon the excited fluorophores. Experimental data agree with a theoretical model. Our results encourage further increasing the linear scanning speed for photobleaching reduction in STED microscopy.

  13. Ultra high field magnetic resonance imaging

    International Nuclear Information System (INIS)

    Lethimonnier, F.; Vedrine, P.

    2007-01-01

    Understanding human brain function, brain development and brain dysfunction is one of the great challenges of the twenty first century. Biomedical imaging has now run up against a number of technical constraints that are exposing limits to its potential. In order to overcome the current limits to high-field magnetic resonance cerebral imaging (MRI) and unleash its fullest potential, the Cea has built NeuroSpin, an ultra-high-field neuroimaging facility at its Saclay centre (in the Essonne). NeuroSpin already boasts three fully operational MRI systems. The first is a 3-tesla high-field system and the second is a very-high-field 7-tesla system, both of which are dedicated to clinical studies and investigations in humans, while the third is an ultra-high-field 17.65-tesla system designed for studies on small animals. In 2011, NeuroSpin will be commissioning an 11.7-tesla ultra-high-field system of unprecedented power that is designed for research on human subjects. The level of the magnetic field and the scale required will make this joint French-German project to build the magnet a breakthrough in the international arena. (authors)

  14. A control system of a mini survey facility for photometric monitoring

    Science.gov (United States)

    Tsutsui, Hironori; Yanagisawa, Kenshi; Izumiura, Hideyuki; Shimizu, Yasuhiro; Hanaue, Takumi; Ita, Yoshifusa; Ichikawa, Takashi; Komiyama, Takahiro

    2016-08-01

    We have built a control system for a mini survey facility dedicated to photometric monitoring of nearby bright (Kdome and a small (30-mm aperture) wide-field (5 × 5 sq. deg. field of view) infrared (1.0-2.5 microns) camera on an equatorial fork mount, as well as power sources and other associated equipment. All the components other than the camera are controlled by microcomputerbased I/O boards that were developed in-house and are in many of the open-use instruments in our observatory. We present the specifications and configuration of the facility hardware, as well as the structure of its control software.

  15. Structure functions at small xBj in a Euclidean field theory approach

    International Nuclear Information System (INIS)

    Hebecker, A.; Meggiolaro, E.; Nachtmann, O.

    2000-01-01

    The small-x Bj limit of deep inelastic scattering is related to the high-energy limit of the forward Compton amplitude in a familiar way. We show that the analytic continuation of this amplitude in the energy variable is calculable from a matrix element in Euclidean field theory. This matrix element can be written as a Euclidean functional integral in an effective field theory. Its effective Lagrangian has a simple expression in terms of the original Lagrangian. The functional integral expression obtained can, at least in principle, be evaluated using genuinely non-perturbative methods, e.g., on the lattice. Thus, a fundamentally new approach to the long-standing problem of structure functions at very small x Bj seems possible. We give arguments that the limit x Bj →0 corresponds to a critical point of the effective field theory where the correlation length becomes infinite in one direction

  16. A Historical View and Vision into the Future of the Field of Safety Pharmacology.

    Science.gov (United States)

    Bass, Alan S; Hombo, Toshiyasu; Kasai, Chieko; Kinter, Lewis B; Valentin, Jean-Pierre

    2015-01-01

    Professor Gerhard Zbinden recognized in the 1970s that the standards of the day for testing new candidate drugs in preclinical toxicity studies failed to identify acute pharmacodynamic adverse events that had the potential to harm participants in clinical trials. From his vision emerged the field of safety pharmacology, formally defined in the International Conference on Harmonization (ICH) S7A guidelines as "those studies that investigate the potential undesirable pharmacodynamic effects of a substance on physiological functions in relation to exposure in the therapeutic range and above." Initially, evaluations of small-molecule pharmacodynamic safety utilized efficacy models and were an ancillary responsibility of discovery scientists. However, over time, the relationship of these studies to overall safety was reflected by the regulatory agencies who, in directing the practice of safety pharmacology through guidance documents, prompted transition of responsibility to drug safety departments (e.g., toxicology). Events that have further shaped the field over the past 15 years include the ICH S7B guidance, evolution of molecular technologies leading to identification of new therapeutic targets with uncertain toxicities, introduction of data collection using more sophisticated and refined technologies, and utilization of transgenic animal models probing critical scientific questions regarding novel targets of toxicity. The collapse of the worldwide economy in the latter half of the first decade of the twenty-first century, continuing high rates of compound attrition during clinical development and post-approval and sharply increasing costs of drug development have led to significant strategy changes, contraction of the size of pharmaceutical organizations, and refocusing of therapeutic areas of investigation. With these changes has come movement away from dedicated internal safety pharmacology capability to utilization of capabilities within external contract

  17. Microcontinuum field theories

    CERN Document Server

    Eringen, A Cemal

    1999-01-01

    Microcontinuum field theories constitute an extension of classical field theories -- of elastic bodies, deformations, electromagnetism, and the like -- to microscopic spaces and short time scales. Material bodies are here viewed as collections of large numbers of deformable particles, much as each volume element of a fluid in statistical mechanics is viewed as consisting of a large number of small particles for which statistical laws are valid. Classical continuum theories are valid when the characteristic length associated with external forces or stimuli is much larger than any internal scale of the body under consideration. When the characteristic lengths are comparable, however, the response of the individual constituents becomes important, for example, in considering the fluid or elastic properties of blood, porous media, polymers, liquid crystals, slurries, and composite materials. This volume is concerned with the kinematics of microcontinua. It begins with a discussion of strain, stress tensors, balanc...

  18. Small-field fractionated radiotherapy with or without stereotactic boost for vestibular schwannoma

    International Nuclear Information System (INIS)

    Kagei, K.; Shirato, H.; Suzuki, K.; Isu, T.; Sawamura, Y.; Sakamoto, T.; Fukuda, S.; Nishioka, T.; Hashimoto, S.; Miyasaka, K.

    1999-01-01

    Purpose: To assess the efficacy and toxicity of small-field fractionated radiotherapy with or without stereotactic boost (SB) for vestibular schwannomas.Methods and materials: Thirty-nine patients with vestibular schwannoma were treated with irradiation between March 1991 and February 1996. Extra-meatal tumor diameters were under 30 mm. Thirty-three patients received small-field fractionated radiotherapy followed by SB. Basic dose schedule was 44 Gy in 22 fractions over 5 1/2 weeks plus 4 Gy in one session. Six patients received small-field fractionated radiotherapy only (40-44 Gy in 20-22 fractions over 5-5 1/2 weeks or 36 Gy in 20 fractions over 5 weeks).< Results: Follow-up ranged from 6 to 69 months (median, 24 months). Tumors decreased in size in 13 cases (33%), were unchanged in 25 (64%), and increased in one (3%). The actuarial 2-year tumor control rate was 97%. Fifteen patients had useful hearing (Gardner-Robertson class 1-2) and 25 patients had testable hearing (class 1-4) before irradiation. The 2-year actuarial rates of useful hearing preservation (free of deterioration from class 1-2 to class 3-5) were 78%. The 2-year actuarial rates of any testable hearing preservation (free of deterioration from class 1-4 to class 5) were 96%. No permanent facial and trigeminal neuropathy developed after irradiation. The 2-year actuarial incidences of facial and trigeminal neuropathies were 8% and 16%, respectively.Conclusions: Small-field fractionated radiotherapy with or without SB provides excellent short-term local control and a relatively low incidence of complications for vestibular schwannoma, although further follow-up is necessary to evaluate the long-term results. (Copyright (c) 1999 Elsevier Science B.V., Amsterdam. All rights reserved.)

  19. Effects of small radiation doses

    International Nuclear Information System (INIS)

    Fuchs, G.

    1986-01-01

    The term 'small radiation dosis' means doses of about (1 rem), fractions of one rem as well as doses of a few rem. Doses like these are encountered in various practical fields, e.g. in X-ray diagnosis, in the environment and in radiation protection rules. The knowledge about small doses is derived from the same two forces, on which the radiobiology of human beings nearly is based: interpretation of the Hiroshima and Nagasaki data, as well as the experience from radiotherapy. Careful interpretation of Hiroshima dates do not provide any evidence that small doses can induce cancer, fetal malformations or genetic damage. Yet in radiotherapy of various diseases, e.g. inflammations, doses of about 1 Gy (100 rad) do no harm to the patients. According to a widespread hypothesis even very small doses may induce some types of radiation damage ('no threshold'). Nevertheless an alternative view is justified. At present no decision can be made between these two alternatives, but the usefullness of radiology is definitely better established than any damage calculated by theories or extrapolations. Based on experience any exaggerated fear of radiations can be met. (author)

  20. Factors affecting radiation doses from dedicated rail transport of spent reactor fuel

    International Nuclear Information System (INIS)

    Martin, J.E.

    1988-01-01

    This paper reports there are two exposure control concerns associated with the shipment of spent reactor fuel in dedicated trains -- compliance with transportation regulations for maximum allowable radiation levels, and minimizing the dose received by the general public. This article examines the methods used to calculate the dose equivalent rates alongside stationary (transport regulations) and moving trains (public exposure) of various lengths. The factors examined include the source term, the effect of overlapping radiation fields, the speed of the train, and the location of the population relative to the train. Trains made up of series of cars that individually meet transport regulations can, as a whole, exceed transport vehicle dose equivalent rate limits by up to 23% due to overlapping radiation fields. For moving trains and the worst case analyzed -- a person located 20 feet from the tracks and a train speed of 5 mph --- 141 rail cars would have to pass by to deliver a dose equivalent of 1 mrem

  1. Feasibility analysis of the Primary Loop of Pool-Type Natural Circulating Nuclear Reactor Dedicated to Seawater Desalination

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Woonho; Jeong, Yong Hoon [KAIST, Daejeon (Korea, Republic of)

    2016-05-15

    In this study, the feasibility of natural circulation was evaluated for the reference plant AHR400 (Advanced Heating Reactor 400MWth). AHR400 is a pool-type desalination-dedicated nuclear reactor. As a consequence, AHR400 has low operating pressure and temperature which provides large safety margin. Removal of the reactor coolant pump from the AHR400 will enforce integrity of the reactor vessel and passive safety feature. Therefore, the study also tried to find out optimized primary loop design to achieve total natural circulation of the coolant. Natural circulation capacity of the primary loop of the desalination dedicated nuclear reactor AHR400 was evaluated. It was concluded that to remove RCP from the AHR400 and operates the reactor only by natural circulation of the coolant is impossible. Decreased core power as half make removal of RCP possible with 15m central height difference between the core and IHXs. Furthermore, validation and modification of pressure loss coefficients by small-scaled natural circulation experiment at a pool-type reactor would provide more accurate results.

  2. PSF Estimation of Space-Variant Ultra-Wide Field of View Imaging Systems

    Directory of Open Access Journals (Sweden)

    Petr Janout

    2017-02-01

    Full Text Available Ultra-wide-field of view (UWFOV imaging systems are affected by various aberrations, most of which are highly angle-dependent. A description of UWFOV imaging systems, such as microscopy optics, security camera systems and other special space-variant imaging systems, is a difficult task that can be achieved by estimating the Point Spread Function (PSF of the system. This paper proposes a novel method for modeling the space-variant PSF of an imaging system using the Zernike polynomials wavefront description. The PSF estimation algorithm is based on obtaining field-dependent expansion coefficients of the Zernike polynomials by fitting real image data of the analyzed imaging system using an iterative approach in an initial estimate of the fitting parameters to ensure convergence robustness. The method is promising as an alternative to the standard approach based on Shack–Hartmann interferometry, since the estimate of the aberration coefficients is processed directly in the image plane. This approach is tested on simulated and laboratory-acquired image data that generally show good agreement. The resulting data are compared with the results of other modeling methods. The proposed PSF estimation method provides around 5% accuracy of the optical system model.

  3. Small Form Factor RFID Applicator, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — The proposed development of a small form factor Astrobee dedicated RFID label applicator will allow current and future free flying vehicles to place RFID labels...

  4. Wavefield back-propagation in high-resolution X-ray holography with a movable field of view.

    Science.gov (United States)

    Guehrs, Erik; Günther, Christian M; Pfau, Bastian; Rander, Torbjörn; Schaffert, Stefan; Schlotter, William F; Eisebitt, Stefan

    2010-08-30

    Mask-based Fourier transform holography is used to record images of biological objects with 2.2 nm X-ray wavelength. The holography mask and the object are decoupled from each other which allows us to move the field of view over a large area over the sample. Due to the separation of the mask and the sample on different X-ray windows, a gap between both windows in the micrometer range typically exists. Using standard Fourier transform holography, focussed images of the sample can directly be reconstructed only for gap distances within the setup's depth of field. Here, we image diatoms as function of the gap distance and demonstrate the possibility to recover focussed images via a wavefield back-propagation technique. The limitations of our approach with respect to large separations are mainly associated with deviations from flat-field illumination of the object.

  5. The MWA archive infrastructure: archiving terabytes of data over dedicated WAN connections

    Science.gov (United States)

    Wicenec, Andreas; Pallot, Dave; Checcucci, Alessio; Kitaeff, Slava; Vinsen, Kevin; Wu, Chen

    2012-09-01

    The Murchison Wide Field Array (MWA) is being upgraded from 32 tiles to 128 tiles of 16 dual-polarization dipole antennas. In the course of this project the software and the data infrastructure are also undergoing a major overhaul in order to cope with a more continuous and remote operational model; and the substantial increase in data rate (400 MB/s from the correlator plus 160 MB/s from the real time imaging pipeline). During the course of 2012/13 the data collected by the MWA will be transported via a dedicated 40 Gbit WAN network link between the Murchison Radio Observatory (MRO) and Perth (700 km). However, this network will not be available for some time; and until then, the data will be transported using disk arrays instead. Once in Perth, the data will be ingested into a tape library. The archiving process itself consists of various steps executed either at the MRO site or in Perth, and makes use of a modied version of the archiving system from the Atacama Large Millimeter Array (ALMA). This includes the extraction of meta-data from the original raw data and the ingestion and generation of the appropriate data links for the MWA archive. The MWA correlator generates a collection of small les all belonging to the same observation. In order to optimise the network transfer and the storage of those les they are transparently packed into larger containers at the MRO site and subsequently handled as one big le. This paper describes the setup of the MWA archiving infrastructure.

  6. Effects of AC Electric Field on Small Laminar Nonpremixed Flames

    KAUST Repository

    Xiong, Yuan

    2015-04-01

    Electric field can be a viable method in controlling various combustion properties. Comparing to traditional actuators, an application of electric field requires very small power consumption. Especially, alternating current (AC) has received attention recently, since it could modulate flames appreciably even for the cases when direct current (DC) has minimal effects. In this study, the effect of AC electric fields on small coflow diffusion flames is focused with applications of various laser diagnostic techniques. Flow characteristics of baseline diffusion flames, which corresponds to stationary small coflow diffusion flames when electric field is not applied, were firstly investigated with a particular focus on the flow field in near-nozzle region with the buoyancy force exerted on fuels due to density differences among fuel, ambient air, and burnt gas. The result showed that the buoyancy force exerted on the fuel as well as on burnt gas significantly distorted the near-nozzle flow-fields. In the fuels with densities heavier than air, recirculation zones were formed very close to the nozzle exit. Nozzle heating effect influenced this near-nozzle flow-field particularly among lighter fuels. Numerical simulations were also conducted and the results showed that a fuel inlet boundary condition with a fully developed velocity profile for cases with long fuel tubes should be specified inside the fuel tube to obtain satisfactory agreement in both the flow and temperature fields with those from experiment. With sub-critical AC applied to the baseline flames, particle image velocimetry (PIV), light scattering, laser-induced incandescence (LII), and laser-induced fluores- cence (LIF) techniques were adopted to identify the flow field and the structures of OH, polycyclic aromatic hydrocarbons (PAHs), soot zone. Under certain AC condi- tions of applied voltage and frequency, the distribution of PAHs and the flow field near the nozzle exit were drastically altered from the

  7. Current status and future perspectives of in vivo small animal imaging using radiolabeled nanoparticles

    International Nuclear Information System (INIS)

    Loudos, George; Kagadis, George C.; Psimadas, Dimitris

    2011-01-01

    Small animal molecular imaging is a rapidly expanding efficient tool to study biological processes non-invasively. The use of radiolabeled tracers provides non-destructive, imaging information, allowing time related phenomena to be repeatedly studied in a single animal. In the last decade there has been an enormous progress in related technologies and a number of dedicated imaging systems overcome the limitations that the size of small animal possesses. On the other hand, nanoparticles (NPs) gain increased interest, due to their unique properties, which make them perfect candidates for biological applications. Over the past 5 years the two fields seem to cross more and more often; radiolabeled NPs have been assessed in numerous pre-clinical studies that range from oncology, till HIV treatment. In this article the current status in the tools, applications and trends of radiolabeled NPs reviewed.

  8. Impulse breakdown of small air gap in electric field Part II: Statistical ...

    African Journals Online (AJOL)

    The patterns of shot distribution and maximum coverage at impulse breakdown voltage for positive point electr-odes (needle and cone electrodes) in small air gaps in non-uniform electric fields were investigated. During the breakdown test, a sheet of paper was placed on the plate electrode (-ve), and each breakdown shot ...

  9. SU-G-BRB-12: Polarity Effects in Small Volume Ionization Chambers in Small Fields

    International Nuclear Information System (INIS)

    Arora, V; Parsai, E; Mathew, D; Tanny, S; Sperling, N

    2016-01-01

    Purpose: Dosimetric quantities such as the polarity correction factor (Ppol) are important parameters for determining the absorbed dose and can influence the choice of dosimeter. Ppol has been shown to depend on beam energy, chamber design, and field size. This study is to investigate the field size and detector orientation dependence of Ppol in small fields for several commercially available micro-chambers. Methods: We evaluate the Exradin A26, Exradin A16, PTW 31014, PTW 31016, and two prototype IBA CC-01 micro-chambers in both horizontal and vertical orientations. Measurements were taken at 10cm depth and 100cm SSD in a Wellhofer BluePhantom2. Measurements were made at square fields of 0.6, 0.8, 1.0, 1.2, 1.4, 2.0, 2.4, 3.0, and 5.0 cm on each side using 6MV with both ± 300VDC biases. PPol was evaluated as described in TG-51, reported using −300VDC bias for Mraw. Ratios of PPol measured in the clinical field to the reference field are presented. Results: A field size dependence of Ppol was observed for all chambers, with increased variations when mounted vertically. The maximum variation observed in PPol over all chambers mounted horizontally was <1%, and occurred at different field sizes for different chambers. Vertically mounted chambers demonstrated variations as large as 3.2%, always at the smallest field sizes. Conclusion: Large variations in Ppol were observed for vertically mounted chambers compared to horizontal mountings. Horizontal mountings demonstrated a complicated relationship between polarity variation and field size, probably relating to differing details in each chambers construction. Vertically mounted chambers consistently demonstrated the largest PPol variations for the smallest field sizes. Measurements obtained with a horizontal mounting appear to not need significant polarity corrections for relative measurements, while those obtained using a vertical mounting should be corrected for variations in PPol.

  10. SU-G-BRB-12: Polarity Effects in Small Volume Ionization Chambers in Small Fields

    Energy Technology Data Exchange (ETDEWEB)

    Arora, V; Parsai, E [University of Toledo Medical Center, Toledo, OH (United States); Mathew, D [University of Minnesota, Minneapolis, MN (United States); Tanny, S [SUNY Upstate Medical University, Syracuse NY (United States); Sperling, N [University of Toledo Medical Center, Sylvania, OH (United States)

    2016-06-15

    Purpose: Dosimetric quantities such as the polarity correction factor (Ppol) are important parameters for determining the absorbed dose and can influence the choice of dosimeter. Ppol has been shown to depend on beam energy, chamber design, and field size. This study is to investigate the field size and detector orientation dependence of Ppol in small fields for several commercially available micro-chambers. Methods: We evaluate the Exradin A26, Exradin A16, PTW 31014, PTW 31016, and two prototype IBA CC-01 micro-chambers in both horizontal and vertical orientations. Measurements were taken at 10cm depth and 100cm SSD in a Wellhofer BluePhantom2. Measurements were made at square fields of 0.6, 0.8, 1.0, 1.2, 1.4, 2.0, 2.4, 3.0, and 5.0 cm on each side using 6MV with both ± 300VDC biases. PPol was evaluated as described in TG-51, reported using −300VDC bias for Mraw. Ratios of PPol measured in the clinical field to the reference field are presented. Results: A field size dependence of Ppol was observed for all chambers, with increased variations when mounted vertically. The maximum variation observed in PPol over all chambers mounted horizontally was <1%, and occurred at different field sizes for different chambers. Vertically mounted chambers demonstrated variations as large as 3.2%, always at the smallest field sizes. Conclusion: Large variations in Ppol were observed for vertically mounted chambers compared to horizontal mountings. Horizontal mountings demonstrated a complicated relationship between polarity variation and field size, probably relating to differing details in each chambers construction. Vertically mounted chambers consistently demonstrated the largest PPol variations for the smallest field sizes. Measurements obtained with a horizontal mounting appear to not need significant polarity corrections for relative measurements, while those obtained using a vertical mounting should be corrected for variations in PPol.

  11. A far-field-viewing sensor for making analytical measurements in remote locations.

    Science.gov (United States)

    Michael, K L; Taylor, L C; Walt, D R

    1999-07-15

    We demonstrate a far-field-viewing GRINscope sensor for making analytical measurements in remote locations. The GRINscope was fabricated by permanently affixing a micro-Gradient index (GRIN) lens on the distal face of a 350-micron-diameter optical imaging fiber. The GRINscope can obtain both chemical and visual information. In one application, a thin, pH-sensitive polymer layer was immobilized on the distal end of the GRINscope. The ability of the GRINscope to visually image its far-field surroundings and concurrently detect pH changes in a flowing stream was demonstrated. In a different application, the GRINscope was used to image pH- and O2-sensitive particles on a remote substrate and simultaneously measure their fluorescence intensity in response to pH or pO2 changes.

  12. Cone-beam micro computed tomography dedicated to the breast.

    Science.gov (United States)

    Sarno, Antonio; Mettivier, Giovanni; Di Lillo, Francesca; Cesarelli, Mario; Bifulco, Paolo; Russo, Paolo

    2016-12-01

    We developed a scanner for micro computed tomography dedicated to the breast (BµCT) with a high resolution flat-panel detector and a microfocus X-ray tube. We evaluated the system spatial resolution via the 3D modulation transfer function (MTF). In addition to conventional absorption-based X-ray imaging, such a prototype showed capabilities for propagation-based phase-contrast and related edge enhancement effects in 3D imaging. The system limiting spatial resolution is 6.2mm -1 (MTF at 10%) in the vertical direction and 3.8mm -1 in the radial direction, values which compare favorably with the spatial resolution reached by mini focus breast CT scanners of other groups. The BµCT scanner was able to detect both microcalcification clusters and masses in an anthropomorphic breast phantom at a dose comparable to that of two-view mammography. The use of a breast holder is proposed in order to have 1-2min long scan times without breast motion artifacts. Copyright © 2016 IPEM. Published by Elsevier Ltd. All rights reserved.

  13. Dedicated mobile volumetric cone-beam computed tomography for human brain imaging: A phantom study.

    Science.gov (United States)

    Ryu, Jong-Hyun; Kim, Tae-Hoon; Jeong, Chang-Won; Jun, Hong-Young; Heo, Dong-Woon; Lee, Jinseok; Kim, Kyong-Woo; Yoon, Kwon-Ha

    2015-01-01

    Mobile computed tomography (CT) with a cone-beam source is increasingly used in the clinical field. Mobile cone-beam CT (CBCT) has great merits; however, its clinical utility for brain imaging has been limited due to problems including scan time and image quality. The aim of this study was to develop a dedicated mobile volumetric CBCT for obtaining brain images, and to optimize the imaging protocol using a brain phantom. The mobile volumetric CBCT system was evaluated with regards to scan time and image quality, measured as signal-to-noise-ratio (SNR), contrast-to-noise-ratio (CNR), spatial resolution (10% MTF), and effective dose. Brain images were obtained using a CT phantom. The CT scan took 5.14 s at 360 projection views. SNR and CNR were 5.67 and 14.5 at 120 kV/10 mA. SNR and CNR values showed slight improvement as the x-ray voltage and current increased (p < 0.001). Effective dose and 10% MTF were 0.92 mSv and 360 μ m at 120 kV/10 mA. Various intracranial structures were clearly visible in the brain phantom images. Using this CBCT under optimal imaging acquisition conditions, it is possible to obtain human brain images with low radiation dose, reproducible image quality, and fast scan time.

  14. View of the Axial Field Spectrometer

    CERN Multimedia

    1980-01-01

    The Axial Field Spectrometer, with the vertical uranium/scintillator calorimeter and the central drift chamber retracted for service. One coil of the Open Axial Field Magnet is just visible to the right.

  15. Initial reconstruction results from a simulated adaptive small animal C shaped PET/MR insert

    Energy Technology Data Exchange (ETDEWEB)

    Efthimiou, Nikos [Technological Educational Institute of Athens (Greece); Kostou, Theodora; Papadimitroulas, Panagiotis [Technological Educational Institute of Athens (Greece); Department of Medical Physics, School of Medicine, University of Patras (Greece); Charalampos, Tsoumpas [Division of Biomedical Imaging, University of Leeds, Leeds (United Kingdom); Loudos, George [Technological Educational Institute of Athens (Greece)

    2015-05-18

    Traditionally, most clinical and preclinical PET scanners, rely on full cylindrical geometry for whole body as well as dedicated organ scans, which is not optimized with regards to sensitivity and resolution. Several groups proposed the construction of dedicated PET inserts for MR scanners, rather than the construction of new integrated PET/MR scanners. The space inside an MR scanner is a limiting factor which can be reduced further with the use of extra coils, and render the use of non-flexible cylindrical PET scanners difficult if not impossible. The incorporation of small SiPM arrays, can provide the means to design adaptive PET scanners to fit in tight locations, which, makes imaging possible and improve the sensitivity, due to the closer approximation to the organ of interest. In order to assess the performance of such a device we simulated the geometry of a C shaped PET, using GATE. The design of the C-PET was based on a realistic SiPM-BGO scenario. In order reconstruct the simulated data, with STIR, we had to calculate system probability matrix which corresponds to this non standard geometry. For this purpose we developed an efficient multi threaded ray tracing technique to calculate the line integral paths in voxel arrays. One of the major features is the ability to automatically adjust the size of FOV according to the geometry of the detectors. The initial results showed that the sensitivity improved as the angle between the detector arrays increases, thus better angular sampling the scanner's field of view (FOV). The more complete angular coverage helped in improving the shape of the source in the reconstructed images, as well. Furthermore, by adapting the FOV to the closer to the size of the source, the sensitivity per voxel is improved.

  16. Initial reconstruction results from a simulated adaptive small animal C shaped PET/MR insert

    International Nuclear Information System (INIS)

    Efthimiou, Nikos; Kostou, Theodora; Papadimitroulas, Panagiotis; Charalampos, Tsoumpas; Loudos, George

    2015-01-01

    Traditionally, most clinical and preclinical PET scanners, rely on full cylindrical geometry for whole body as well as dedicated organ scans, which is not optimized with regards to sensitivity and resolution. Several groups proposed the construction of dedicated PET inserts for MR scanners, rather than the construction of new integrated PET/MR scanners. The space inside an MR scanner is a limiting factor which can be reduced further with the use of extra coils, and render the use of non-flexible cylindrical PET scanners difficult if not impossible. The incorporation of small SiPM arrays, can provide the means to design adaptive PET scanners to fit in tight locations, which, makes imaging possible and improve the sensitivity, due to the closer approximation to the organ of interest. In order to assess the performance of such a device we simulated the geometry of a C shaped PET, using GATE. The design of the C-PET was based on a realistic SiPM-BGO scenario. In order reconstruct the simulated data, with STIR, we had to calculate system probability matrix which corresponds to this non standard geometry. For this purpose we developed an efficient multi threaded ray tracing technique to calculate the line integral paths in voxel arrays. One of the major features is the ability to automatically adjust the size of FOV according to the geometry of the detectors. The initial results showed that the sensitivity improved as the angle between the detector arrays increases, thus better angular sampling the scanner's field of view (FOV). The more complete angular coverage helped in improving the shape of the source in the reconstructed images, as well. Furthermore, by adapting the FOV to the closer to the size of the source, the sensitivity per voxel is improved.

  17. Observations of volcanic plumes using small balloon soundings

    Science.gov (United States)

    Voemel, H.

    2015-12-01

    Eruptions of volcanoes are very difficult to predict and for practical purposes may occur at any time. Any observing system intending to observe volcanic eruptions has to be ready at any time. Due to transport time scales, emissions of large volcanic eruptions, in particular injections into the stratosphere, may be detected at locations far from the volcano within days to weeks after the eruption. These emissions may be observed using small balloon soundings at dedicated sites. Here we present observations of particles of the Icelandic Grimsvotn eruption at the Meteorological Observatory Lindenberg, Germany in the months following the eruption and observations of opportunity of other volcanic particle events. We also present observations of the emissions of SO2 from the Turrialba volcano at San Jose, Costa Rica. We argue that dedicated sites for routine observations of the clean and perturbed atmosphere using small sounding balloons are an important element in the detection and quantification of emissions from future volcanic eruptions.

  18. Subcycle dynamics of Coulomb asymmetry in strong elliptical laser fields.

    Science.gov (United States)

    Li, Min; Liu, Yunquan; Liu, Hong; Ning, Qicheng; Fu, Libin; Liu, Jie; Deng, Yongkai; Wu, Chengyin; Peng, Liang-You; Peng, Liangyou; Gong, Qihuang

    2013-07-12

    We measure photoelectron angular distributions of noble gases in intense elliptically polarized laser fields, which indicate strong structure-dependent Coulomb asymmetry. Using a dedicated semiclassical model, we have disentangled the contribution of direct ionization and multiple forward scattering on Coulomb asymmetry in elliptical laser fields. Our theory quantifies the roles of the ionic potential and initial transverse momentum on Coulomb asymmetry, proving that the small lobes of asymmetry are induced by direct ionization and the strong asymmetry is induced by multiple forward scattering in the ionic potential. Both processes are distorted by the Coulomb force acting on the electrons after tunneling. Lowering the ionization potential, the relative contribution of direct ionization on Coulomb asymmetry substantially decreases and Coulomb focusing on multiple rescattering is more important. We do not observe evident initial longitudinal momentum spread at the tunnel exit according to our simulation.

  19. Assessment of dedicated revenue of non-educational hospitals in Guilan University of Medical Sciences (2012

    Directory of Open Access Journals (Sweden)

    S. Asefzadeh

    2015-06-01

    Full Text Available Hospitals, as one of the main providers of health services, are of great importance in health and economy. The aim of this descriptive study was to assess the dedicated revenue of all non-educational hospitals in Guilan University of Medical Sciences (14 hospitals in 2012. On average, 22.35% of income was provided by cash earnings and 77.65% was provided by insurance organizations.There was 1.25% deficit by insurance. The net income of small hospitals with few available beds was very low and they were not economically affordable. The out of pocket to total income ratio was higher in the hospitals located in deprived areas due to lack of full insurance coverage.

  20. Usefulness of a Small-Field Digital Mammographic Imaging System Using Parabolic Polycapillary Optics as a Diagnostic Imaging Tool: a Preliminary Study

    International Nuclear Information System (INIS)

    Chon, Kwon Su; Park, Jeong Gon; Son, Hyun Hwa; Kang, Sung Hoon; Park, Seong Hoon; Kim, Hye Won; Kim, Hun Soo; Yoon, Kwon Ha

    2009-01-01

    To evaluate the efficacy for spatial resolution and radiation dose of a small-field digital mammographic imaging system using parabolic polycapillary optics. We developed a small-field digital mammographic imaging system composed of a CCD (charge coupled device) detector and an Xray source coupled with parabolic polycapillary optics. The spatial resolution and radiation dose according to various filters were evaluated for a small-field digital mammographic imaging system. The images of a test standard phantom and breast cancer tissue sample were obtained. The small-field digital mammographic imaging system had spatial resolutions of 12 lp/mm with molybdenum and rhodium filters with a 25-μm thickness. With a thicker molybdenum filter (100 μm thick), the system had a higher spatial resolution of 11 lp/mm and contrast of 0.48. The radiation dose for a rhodium filter with a 25-μm thickness was 0.13 mGy within a 10-mm-diameter local field. A larger field image greater than 10 mm in diameter could be obtained by scanning an object. On the small-field mammographic imaging system, microcalcifications of breast cancer tissue were clearly observed. A small-field digital mammographic imaging system with parabolic polycapillary optics may be a useful diagnostic tool for providing high-resolution imaging with a low radiation dose for examination of local volumes of breast tissue

  1. Usefulness of a Small-Field Digital Mammographic Imaging System Using Parabolic Polycapillary Optics as a Diagnostic Imaging Tool: a Preliminary Study

    Energy Technology Data Exchange (ETDEWEB)

    Chon, Kwon Su [Catholic University of Daegu, Daegu (Korea, Republic of); Park, Jeong Gon; Son, Hyun Hwa; Kang, Sung Hoon; Park, Seong Hoon; Kim, Hye Won; Kim, Hun Soo; Yoon, Kwon Ha [Wonkwang University, Iksan (Korea, Republic of)

    2009-12-15

    To evaluate the efficacy for spatial resolution and radiation dose of a small-field digital mammographic imaging system using parabolic polycapillary optics. We developed a small-field digital mammographic imaging system composed of a CCD (charge coupled device) detector and an Xray source coupled with parabolic polycapillary optics. The spatial resolution and radiation dose according to various filters were evaluated for a small-field digital mammographic imaging system. The images of a test standard phantom and breast cancer tissue sample were obtained. The small-field digital mammographic imaging system had spatial resolutions of 12 lp/mm with molybdenum and rhodium filters with a 25-{mu}m thickness. With a thicker molybdenum filter (100 {mu}m thick), the system had a higher spatial resolution of 11 lp/mm and contrast of 0.48. The radiation dose for a rhodium filter with a 25-{mu}m thickness was 0.13 mGy within a 10-mm-diameter local field. A larger field image greater than 10 mm in diameter could be obtained by scanning an object. On the small-field mammographic imaging system, microcalcifications of breast cancer tissue were clearly observed. A small-field digital mammographic imaging system with parabolic polycapillary optics may be a useful diagnostic tool for providing high-resolution imaging with a low radiation dose for examination of local volumes of breast tissue.

  2. WE-FG-207A-00: Advances in Dedicated Breast CT

    International Nuclear Information System (INIS)

    2016-01-01

    investigating dedicated breast CT. The development of large-area flat-panel detectors with field-of-view sufficient to image the entire breast in each projection enabled development of flat-panel cone-beam breast CT. More recently, the availability of complimentary metal-oxide semiconductor (CMOS) detectors with lower system noise and finer pixel pitch, combined with the development of x-ray tubes with focal spot dimensions similar to mammography systems, has shown improved spatial resolution and could improve visualization of microcalcifications. These technological developments promise clinical translation of low-dose cone-beam breast CT. Dedicated photon-counting breast CT (pcBCT) systems represent a novel detector design, which provide high spatial resolution (∼ 100µm) and low mean glandular dose (MGD). The CdTe-based direct conversion detector technology was previously evaluated and confirmed by simulations and basic experiments on laboratory setups [Kalender et al., Eur Radiol 22: 1–8, 2012]. Measurements of dose, technical image quality parameters, and surgical specimens on a pcBCT scanner have been completed. Comparative evaluation of surgical specimens showed that pcBCT outperformed mammography and digital breast tomosynthesis with respect to 3D spatial resolution, detectability of calcifications, and soft tissue delineation. Major barriers to widespread clinical use of BCT relate to radiation dose, imaging of microcalcifications, and adequate coverage of breast tissue near the chest wall. Adequate chest wall coverage is also technically challenging but recent progress in x-ray tube, detector and table design now enables full breast coverage in the majority of patients. At this time, BCT has been deemed to be suitable for diagnostic imaging but not yet for screening. The mean glandular dose (MGD) from BCT has been reported to be between 5.7 to 27.8 mGy, and this range is comparable to, and within the range of, the MGD of 2.6 to 31.6 mGy in diagnostic mammography

  3. WE-FG-207A-00: Advances in Dedicated Breast CT

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2016-06-15

    investigating dedicated breast CT. The development of large-area flat-panel detectors with field-of-view sufficient to image the entire breast in each projection enabled development of flat-panel cone-beam breast CT. More recently, the availability of complimentary metal-oxide semiconductor (CMOS) detectors with lower system noise and finer pixel pitch, combined with the development of x-ray tubes with focal spot dimensions similar to mammography systems, has shown improved spatial resolution and could improve visualization of microcalcifications. These technological developments promise clinical translation of low-dose cone-beam breast CT. Dedicated photon-counting breast CT (pcBCT) systems represent a novel detector design, which provide high spatial resolution (∼ 100µm) and low mean glandular dose (MGD). The CdTe-based direct conversion detector technology was previously evaluated and confirmed by simulations and basic experiments on laboratory setups [Kalender et al., Eur Radiol 22: 1–8, 2012]. Measurements of dose, technical image quality parameters, and surgical specimens on a pcBCT scanner have been completed. Comparative evaluation of surgical specimens showed that pcBCT outperformed mammography and digital breast tomosynthesis with respect to 3D spatial resolution, detectability of calcifications, and soft tissue delineation. Major barriers to widespread clinical use of BCT relate to radiation dose, imaging of microcalcifications, and adequate coverage of breast tissue near the chest wall. Adequate chest wall coverage is also technically challenging but recent progress in x-ray tube, detector and table design now enables full breast coverage in the majority of patients. At this time, BCT has been deemed to be suitable for diagnostic imaging but not yet for screening. The mean glandular dose (MGD) from BCT has been reported to be between 5.7 to 27.8 mGy, and this range is comparable to, and within the range of, the MGD of 2.6 to 31.6 mGy in diagnostic mammography

  4. Towards the creation of an industrial sector dedicated to nuclear dismantling

    International Nuclear Information System (INIS)

    Anon.

    2015-01-01

    In next decades the business of nuclear dismantling is expected to grow exponentially due to the decommissioning of nuclear facilities that will have reached the end of their operating life. Dismantling has 2 main features: dismantling operations on a same site can span decades and dismantling is a new activity in which innovations are likely to appear and may benefit other sectors. In France regional authorities have promoted public-private partnerships in order to make working together small enterprises very specialized in sectors like robotic, laser cutting, waste processing, remote operations... with public laboratories dedicated to nuclear research, and with graduate schools to include dismantling in curriculum and with major industrial operators of the nuclear industry. The aim is the creation of jobs and the building of an industrial sector able to win market shares in the worldwide business of nuclear dismantling. (A.C.)

  5. What hinders the development of small businesses: the view of the Murmansk Oblast entrepreneurs

    Directory of Open Access Journals (Sweden)

    Tat’yana Igorevna Barasheva

    2014-07-01

    Full Text Available In recent years there has been a slowdown in the growth rate of Russia’s sector of small and medium entrepreneurship; this issue once again brings to the fore the search for new ways and mechanisms in the management of its subjects. A necessary condition for such a search consists in focusing on the problems that hinder the development of this sector and that can be revealed exclusively in the formation of valuable and accurate information – the collective views of its representatives. In this regard, the information base for the analysis was found in the results of several studies initiated by the all-Russian public organization “OPORA Rossii” (Moscow, its regional branch in Murmansk and the Northern Chamber of Commerce and Industry; the results were obtained in the course of the questionnaire survey, which was conducted among entrepreneurs with the purpose of revealing their assessment of the terms of doing business. The generalization of the research results and information obtained by the author in cooperation with representatives of small business and workers of the Prosecutor’s Office has identified the main problems, their causes and consequences of their impact on the activity of the Murmansk Oblast business sector. In the opinion of a significant part of businessmen, such factor as business climate plays a decisive role in the creation and development of the sector in the region. Despite the complexity of the situation, entrepreneurs do not lose hope of solving their problems and see the solution to the problem in efficient work of the regional and municipal authorities. The author’s conclusions may become a reference point for further reforms in the sphere of management of small enterprises in the Murmansk Oblast

  6. The Improved Dual-view Field Goniometer System FIGOS

    Directory of Open Access Journals (Sweden)

    Klaus I. Itten

    2008-08-01

    Full Text Available In spectrodirectional Remote Sensing (RS the Earth’s surface reflectance characteristics are studied by means of their angular dimensions. Almost all natural surfaces exhibit an individual anisotropic reflectance behaviour due to the contrast between the optical properties of surface elements and background and the geometric surface properties of the observed scene. The underlying concept, which describes the reflectance characteristic of a specific surface area, is called the bidirectional reflectance distribution function (BRDF. BRDF knowledge is essential for both correction of directional effects in RS data and quantitative retrieval of surface parameters. Ground-based spectrodirectional measurements are usually performed with goniometer systems. An accurate retrieval of the bidirectional reflectance factors (BRF from field goniometer measurements requires hyperspectral knowledge of the angular distribution of the reflected and the incident radiation. However, prior to the study at hand, no operational goniometer system was able to fulfill this requirement. This study presents the first dual-view field goniometer system, which is able to simultaneously collect both the reflected and the incident radiation at high angular and spectral resolution and, thus, providing the necessary spectrodirectional datasets to accurately retrieve the surface specific BRF. Furthermore, the angular distribution of the incoming diffuse radiation is characterized for various atmospheric conditions and the BRF retrieval is performed for an artificial target and compared to laboratory spectrodirectional measurement results obtained with the same goniometer system. Suggestions for further improving goniometer systems are given and the need for intercalibration of various goniometers as well as for standardizing spectrodirectional measurements is expressed.

  7. Ionospheric response to variable electric fields in small-scale auroral structures

    Directory of Open Access Journals (Sweden)

    B. S. Lanchester

    1998-10-01

    Full Text Available High time and space resolution optical and radar measurements have revealed the influence of electric fields on E-region electron density profiles in small-scale auroral structures. Large electric fields are present adjacent to auroral filaments produced by monoenergetic electron fluxes. The ionisation profiles measured within and beside the auroral filaments show the effects of plasma convection due to electric fields as well as the consequences of the response time to large and dynamic fluxes of energetic electrons. Without high-resolution optical measurements, the interpretation of the radar data is limited.Key words. Auroral ionosphere · Ionosphere-magnetosphere interactions · EISCAT

  8. Ionospheric response to variable electric fields in small-scale auroral structures

    Directory of Open Access Journals (Sweden)

    B. S. Lanchester

    Full Text Available High time and space resolution optical and radar measurements have revealed the influence of electric fields on E-region electron density profiles in small-scale auroral structures. Large electric fields are present adjacent to auroral filaments produced by monoenergetic electron fluxes. The ionisation profiles measured within and beside the auroral filaments show the effects of plasma convection due to electric fields as well as the consequences of the response time to large and dynamic fluxes of energetic electrons. Without high-resolution optical measurements, the interpretation of the radar data is limited.

    Key words. Auroral ionosphere · Ionosphere-magnetosphere interactions · EISCAT

  9. Photometric Calibration and Image Stitching for a Large Field of View Multi-Camera System

    Directory of Open Access Journals (Sweden)

    Yu Lu

    2016-04-01

    Full Text Available A new compact large field of view (FOV multi-camera system is introduced. The camera is based on seven tiny complementary metal-oxide-semiconductor sensor modules covering over 160° × 160° FOV. Although image stitching has been studied extensively, sensor and lens differences have not been considered in previous multi-camera devices. In this study, we have calibrated the photometric characteristics of the multi-camera device. Lenses were not mounted on the sensor in the process of radiometric response calibration to eliminate the influence of the focusing effect of uniform light from an integrating sphere. Linearity range of the radiometric response, non-linearity response characteristics, sensitivity, and dark current of the camera response function are presented. The R, G, and B channels have different responses for the same illuminance. Vignetting artifact patterns have been tested. The actual luminance of the object is retrieved by sensor calibration results, and is used to blend images to make panoramas reflect the objective luminance more objectively. This compensates for the limitation of stitching images that are more realistic only through the smoothing method. The dynamic range limitation of can be resolved by using multiple cameras that cover a large field of view instead of a single image sensor with a wide-angle lens. The dynamic range is expanded by 48-fold in this system. We can obtain seven images in one shot with this multi-camera system, at 13 frames per second.

  10. Faraday Rotation Measure Study of Cluster Magnetic Fields

    Science.gov (United States)

    Frankel, M. M.; Clarke, T. E.

    2001-12-01

    Magnetic fields are thought to play an important role in galaxy cluster evolution. To this end in this study, we looked at polarized radio sources viewed at small impact parameters to the cores of non-cooling flow clusters. By looking at non-cooling flow clusters we hoped to establish what magnetic fields of clusters look like in the absence of the compressed central magnetic fields of the cooling-flow cores. Clarke, Kronberg and Boehringer (2001) examined Faraday rotation measures of radio probes at relatively large impact parameters to the cores of galaxy clusters. The current study is an extension of the Clarke et al. analysis to probe the magnetic fields in the cores of galaxy clusters. We looked at the Faraday rotation of electromagnetic waves from background or imbedded radio galaxies, which were observed with the VLA in A&B arrays. Our results are consistent with previous findings and exhibit a trend towards higher rotation measures and in turn higher magnetic fields at small impact parameters to cluster cores. This research was made possible through funding from the National Science Foundation.

  11. Small Field Dosimetry Comparing Measured Data Versus the ADAC Pinnacle 3 Model

    National Research Council Canada - National Science Library

    Ludolph, Daniel

    2004-01-01

    .... While this method can optimize conformity to tumors and provide better sparing of surrounding tissue, it also presents a host of challenges due to reliance on dosimetry data for small field sizes...

  12. Wide Field-of-View Fluorescence Imaging with Optical-Quality Curved Microfluidic Chamber for Absolute Cell Counting

    Directory of Open Access Journals (Sweden)

    Mohiuddin Khan Shourav

    2016-07-01

    Full Text Available Field curvature and other aberrations are encountered inevitably when designing a compact fluorescence imaging system with a simple lens. Although multiple lens elements can be used to correct most such aberrations, doing so increases system cost and complexity. Herein, we propose a wide field-of-view (FOV fluorescence imaging method with an unconventional optical-quality curved sample chamber that corrects the field curvature caused by a simple lens. Our optics simulations and proof-of-concept experiments demonstrate that a curved substrate with lens-dependent curvature can reduce greatly the distortion in an image taken with a conventional planar detector. Following the validation study, we designed a curved sample chamber that can contain a known amount of sample volume and fabricated it at reasonable cost using plastic injection molding. At a magnification factor of approximately 0.6, the curved chamber provides a clear view of approximately 119 mm2, which is approximately two times larger than the aberration-free area of a planar chamber. Remarkably, a fluorescence image of microbeads in the curved chamber exhibits almost uniform intensity over the entire field even with a simple lens imaging system, whereas the distorted boundary region has much lower brightness than the central area in the planar chamber. The absolute count of white blood cells stained with a fluorescence dye was in good agreement with that obtained by a commercially available conventional microscopy system. Hence, a wide FOV imaging system with the proposed curved sample chamber would enable us to acquire an undistorted image of a large sample volume without requiring a time-consuming scanning process in point-of-care diagnostic applications.

  13. "small ACCELERATORS" 24 May - 2 June 2005

    CERN Multimedia

    2005-01-01

    CERN Accelerator School and Kernfysisch Versneller Instituut (KVI) Groningen, the Netherlands announce a course on "Small Accelerators", Hotel Golden Tulip Drenthe, Zeegse, the Netherlands, 24 May - 2 June 2005. This specialised course is dedicated to the physics and the main applications of small accelerators. The course will review the different accelerator types as well as their specificities in terms of accelerator physics.

  14. Characterization of the exradin W1 plastic scintillation detector for small field applications in proton therapy

    Science.gov (United States)

    Hoehr, C.; Lindsay, C.; Beaudry, J.; Penner, C.; Strgar, V.; Lee, R.; Duzenli, C.

    2018-05-01

    Accurate dosimetry in small field proton therapy is challenging, particularly for applications such as ocular therapy, and suitable detectors for this purpose are sought. The Exradin W1 plastic scintillating fibre detector is known to out-perform most other detectors for determining relative dose factors for small megavoltage photon beams used in radiotherapy but its potential in small proton beams has been relatively unexplored in the literature. The 1 mm diameter cylindrical geometry and near water equivalence of the W1 makes it an attractive alternative to other detectors. This study examines the dosimetric performance of the W1 in a 74 MeV proton therapy beam with particular focus on detector response characteristics relevant to relative dose measurement in small fields suitable for ocular therapy. Quenching of the scintillation signal is characterized and demonstrated not to impede relative dose measurements at a fixed depth. The background cable-only (Čerenkov and radio-fluorescence) signal is 4 orders of magnitude less than the scintillation signal, greatly simplifying relative dose measurements. Comparison with other detectors and Monte Carlo simulations indicate that the W1 is useful for measuring relative dose factors for field sizes down to 5 mm diameter and shallow spread out Bragg peaks down to 6 mm in depth.

  15. A new method for determining which stars are near a star sensor field-of-view

    Science.gov (United States)

    Yates, Russell E., Jr.; Vedder, John D.

    1991-01-01

    A new method is described for determining which stars in a navigation star catalog are near a star sensor field of view (FOV). This method assumes that an estimate of spacecraft inertial attitude is known. Vector component ranges for the star sensor FOV are computed, so that stars whose vector components lie within these ranges are near the star sensor FOV. This method requires no presorting of the navigation star catalog, and is more efficient than tradition methods.

  16. Dedicated mobile high resolution prostate PET imager with an insertable transrectal probe

    Science.gov (United States)

    Majewski, Stanislaw; Proffitt, James

    2010-12-28

    A dedicated mobile PET imaging system to image the prostate and surrounding organs. The imaging system includes an outside high resolution PET imager placed close to the patient's torso and an insertable and compact transrectal probe that is placed in close proximity to the prostate and operates in conjunction with the outside imager. The two detector systems are spatially co-registered to each other. The outside imager is mounted on an open rotating gantry to provide torso-wide 3D images of the prostate and surrounding tissue and organs. The insertable probe provides closer imaging, high sensitivity, and very high resolution predominately 2D view of the prostate and immediate surroundings. The probe is operated in conjunction with the outside imager and a fast data acquisition system to provide very high resolution reconstruction of the prostate and surrounding tissue and organs.

  17. Polarization leakage in epoch of reionization windows - III. Wide-field effects of narrow-field arrays

    Science.gov (United States)

    Asad, K. M. B.; Koopmans, L. V. E.; Jelić, V.; de Bruyn, A. G.; Pandey, V. N.; Gehlot, B. K.

    2018-05-01

    Leakage of polarized Galactic diffuse emission into total intensity can potentially mimic the 21-cm signal coming from the epoch of reionization (EoR), as both of them might have fluctuating spectral structure. Although we are sensitive to the EoR signal only in small fields of view, chromatic side-lobes from further away can contaminate the inner region. Here, we explore the effects of leakage into the `EoR window' of the cylindrically averaged power spectra (PS) within wide fields of view using both observation and simulation of the 3C196 and North Celestial Pole (NCP) fields, two observing fields of the LOFAR-EoR project. We present the polarization PS of two one-night observations of the two fields and find that the NCP field has higher fluctuations along frequency, and consequently exhibits more power at high-k∥ that could potentially leak to Stokes I. Subsequently, we simulate LOFAR observations of Galactic diffuse polarized emission based on a model to assess what fraction of polarized power leaks into Stokes I because of the primary beam. We find that the rms fractional leakage over the instrumental k-space is 0.35 {per cent} in the 3C196 field and 0.27 {per cent} in the NCP field, and it does not change significantly within the diameters of 15°, 9°, and 4°. Based on the observed PS and simulated fractional leakage, we show that a similar level of leakage into Stokes I is expected in the 3C196 and NCP fields, and the leakage can be considered to be a bias in the PS.

  18. How do field of view and resolution affect the information content of panoramic scenes for visual navigation? A computational investigation.

    Science.gov (United States)

    Wystrach, Antoine; Dewar, Alex; Philippides, Andrew; Graham, Paul

    2016-02-01

    The visual systems of animals have to provide information to guide behaviour and the informational requirements of an animal's behavioural repertoire are often reflected in its sensory system. For insects, this is often evident in the optical array of the compound eye. One behaviour that insects share with many animals is the use of learnt visual information for navigation. As ants are expert visual navigators it may be that their vision is optimised for navigation. Here we take a computational approach in asking how the details of the optical array influence the informational content of scenes used in simple view matching strategies for orientation. We find that robust orientation is best achieved with low-resolution visual information and a large field of view, similar to the optical properties seen for many ant species. A lower resolution allows for a trade-off between specificity and generalisation for stored views. Additionally, our simulations show that orientation performance increases if different portions of the visual field are considered as discrete visual sensors, each giving an independent directional estimate. This suggests that ants might benefit by processing information from their two eyes independently.

  19. Influence of thermocleavable functionality on organic field-effect transistor performance of small molecules

    Science.gov (United States)

    Mahale, Rajashree Y.; Dharmapurikar, Satej S.; Chini, Mrinmoy Kumar; Venugopalan, Vijay

    2017-06-01

    Diketopyrrolopyrrole based donor-acceptor-donor conjugated small molecules using ethylene dioxythiophene as a donor was synthesized. Electron deficient diketopyrrolopyrrole unit was substituted with thermocleavable (tert-butyl acetate) side chains. The thermal treatment of the molecules at 160 °C eliminated the tert-butyl ester group results in the formation of corresponding acid. Optical and theoretical studies revealed that the molecules adopted a change in molecular arrangement after thermolysis. The conjugated small molecules possessed p-channel charge transport characteristics in organic field effect transistors. The charge carrier mobility was increased after thermolysis of tert-butyl ester group to 5.07 × 10-5 cm2/V s.

  20. Radial electric field in JET advanced tokamak scenarios with toroidal field ripple

    NARCIS (Netherlands)

    Crombe, K.; Andrew, Y.; Biewer, T. M.; Blanco, E.; de Vries, P. C.; Giroud, C.; Hawkes, N. C.; Meigs, A.; Tala, T.; von Hellermann, M.; Zastrow, K. D.

    2009-01-01

    A dedicated campaign has been run on JET to study the effect of toroidal field (TF) ripple on plasma performance. Radial electric field measurements from experiments on a series of plasmas with internal transport barriers (ITBs) and different levels of ripple amplitude are presented. They have been

  1. NucLab Marcoule. A laboratory facility dedicated to support dismantling operations

    International Nuclear Information System (INIS)

    Dugne, O.; Houssin, A.; Pierre, D.; Bec-Espitalier, L.

    2013-06-01

    Formerly dedicated to plutonium production support, NucLab was renovated to perform a wide range of analyses for dismantling, plant operation and process development activities mainly on Marcoule site but also outside (Veurey, Fontenay aux Roses). The Laboratory is under a CEA AREVA partnership as a CEA entity operated by AREVA employees. It provides services to several industrial operators (nuclear process and power plant) in the fields of analytical chemistry, radioactivity measurements, in situ nuclear measurements, decontamination processes and industrial chemistry processes, waste treatments to meet the following analysis requirements. NucLab today is able to support research, production and dismantling activities in all part of dismantling operations. (authors)

  2. Optimising camera traps for monitoring small mammals.

    Directory of Open Access Journals (Sweden)

    Alistair S Glen

    Full Text Available Practical techniques are required to monitor invasive animals, which are often cryptic and occur at low density. Camera traps have potential for this purpose, but may have problems detecting and identifying small species. A further challenge is how to standardise the size of each camera's field of view so capture rates are comparable between different places and times. We investigated the optimal specifications for a low-cost camera trap for small mammals. The factors tested were 1 trigger speed, 2 passive infrared vs. microwave sensor, 3 white vs. infrared flash, and 4 still photographs vs. video. We also tested a new approach to standardise each camera's field of view. We compared the success rates of four camera trap designs in detecting and taking recognisable photographs of captive stoats (Mustelaerminea, feral cats (Felis catus and hedgehogs (Erinaceuseuropaeus. Trigger speeds of 0.2-2.1 s captured photographs of all three target species unless the animal was running at high speed. The camera with a microwave sensor was prone to false triggers, and often failed to trigger when an animal moved in front of it. A white flash produced photographs that were more readily identified to species than those obtained under infrared light. However, a white flash may be more likely to frighten target animals, potentially affecting detection probabilities. Video footage achieved similar success rates to still cameras but required more processing time and computer memory. Placing two camera traps side by side achieved a higher success rate than using a single camera. Camera traps show considerable promise for monitoring invasive mammal control operations. Further research should address how best to standardise the size of each camera's field of view, maximise the probability that an animal encountering a camera trap will be detected, and eliminate visible or audible cues emitted by camera traps.

  3. Joint development of China's medium/small hydropower projects with international investment

    International Nuclear Information System (INIS)

    Xiaozhang, Z.

    1991-01-01

    A general profile of development of small and medium hydropower in China, is described at first. The socio-economic impacts as well as direct financial benefit will then be analyzed. A prospective view of medium/small hydro development for year 2,000 leads to a description of needs for foreign investment in this field. Following the adoption of open policy, a series of regulations for joint venture with foreign investment have been stipulated by the government, and are briefly illustrated. Future prospect is predicted on the basis of past experiences and planning for the next decade. 3 tabs

  4. Small molecule antagonists of integrin receptors.

    Science.gov (United States)

    Perdih, A; Dolenc, M Sollner

    2010-01-01

    The complex and widespread family of integrin receptors is involved in numerous physiological processes, such as tissue remodeling, angiogenesis, development of the immune response and homeostasis. In addition, their key role has been elucidated in important pathological disorders such as cancer, cardiovascular diseases, osteoporosis, autoimmune and inflammatory diseases and in the pathogenesis of infectious diseases, making them highly important targets for modern drug design campaigns. In this review we seek to present a concise overview of the small molecule antagonists of this diverse and highly complex receptor family. Integrin antagonists are classified according to the targeted integrin receptor and are discussed in four sections. First we present the fibrinogen alpha(IIb)beta3 and the vitronectin alpha (V)beta(3) receptor antagonists. The remaining selective integrin antagonists are examined in the third section. The final section is dedicated to molecules with dual or multiple integrin activity. In addition, the use of antibodies and peptidomimetic approaches to modulate the integrin receptors are discussed, as well providing the reader with an overall appreciation of the field.

  5. Design drivers for a wide-field multi-object spectrograph for the William Herschel Telescope

    NARCIS (Netherlands)

    Balcells, Marc; Benn, Chris R.; Carter, David; Dalton, Gavin B.; Trager, Scott C.; Feltzing, Sofia; Verheijen, M.A.W.; Jarvis, Matt; Percival, Will; Abrams, Don C.; Agocs, Tibor; Brown, Anthony G. A.; Cano, Diego; Evans, Chris; Helmi, Amina; Lewis, Ian J.; McLure, Ross; Peletier, Reynier F.; Pérez-Fournon, Ismael; Sharples, Ray M.; Tosh, Ian A. J.; Trujillo, Ignacio; Walton, Nic; Westhall, Kyle B.

    Wide-field multi-object spectroscopy is a high priority for European astronomy over the next decade. Most 8-10m telescopes have a small field of view, making 4-m class telescopes a particularly attractive option for wide-field instruments. We present a science case and design drivers for a

  6. Pneumothorax in intensive-care patients: Ranking of tangential views

    International Nuclear Information System (INIS)

    Jantsch, H.; Winkler, M.; Pichler, W.; Mauritz, W.; Lechner, G.; Vienna Univ.

    1990-01-01

    In 55 intensive-care patients an additional tangential view of the chest was taken to demonstrate or exclude a pneumothorax in patients with sudden deterioration of gas exchange and negative ap-chest x-ray, if there was a suspicion of pneumothorax or a confirmed small pneumothorax in the ap-view. In 14 of 42 cases (33.3%) with negative or suspected ap-chest x-ray the tangential view revealed a pneumothorax. 6 of these 14 pneumothoraces were under tension. In 7 out of 11 patients (63.6%) with small pneumothorax, the tangential view showed additionally a tensionpneumothorax. (orig.) [de

  7. Development of a dedicated isotope mass spectrometer for the noninvasive diagnostics of humans infected with Helicobacter Pylori

    Science.gov (United States)

    Blashenkov, N. M.; Sheshenya, E. S.; Solov'ev, S. M.; Gall', L. N.; Sachenko, V. M.; Zarutskii, I. V.; Gall', N. R.

    2013-06-01

    A dedicated isotope mass spectrometer for the noninvasive diagnostics of humans infected with Helicobacter Pylori using the isotope respiratory test is developed. A low-aberration mass analyzer is calculated, an input system that makes it possible to eliminate the memory effects is developed, and a small-size ion detector is constructed. The mass spectrometer is created, and the tests are performed. The measurement accuracy of the 13C/12C and 16O/18O isotope ratios are 1.7 and 2.2‰, respectively. Preliminary medical tests show that the spectrometer can be employed for the desired diagnostics.

  8. An automated device for the digitization and 3D modelling of insects, combining extended-depth-of-field and all-side multi-view imaging

    Directory of Open Access Journals (Sweden)

    Bernhard Ströbel

    2018-05-01

    Full Text Available Digitization of natural history collections is a major challenge in archiving biodiversity. In recent years, several approaches have emerged, allowing either automated digitization, extended depth of field (EDOF or multi-view imaging of insects. Here, we present DISC3D: a new digitization device for pinned insects and other small objects that combines all these aspects. A PC and a microcontroller board control the device. It features a sample holder on a motorized two-axis gimbal, allowing the specimens to be imaged from virtually any view. Ambient, mostly reflection-free illumination is ascertained by two LED-stripes circularly installed in two hemispherical white-coated domes (front-light and back-light. The device is equipped with an industrial camera and a compact macro lens, mounted on a motorized macro rail. EDOF images are calculated from an image stack using a novel calibrated scaling algorithm that meets the requirements of the pinhole camera model (a unique central perspective. The images can be used to generate a calibrated and real color texturized 3Dmodel by ‘structure from motion’ with a visibility consistent mesh generation. Such models are ideal for obtaining morphometric measurement data in 1D, 2D and 3D, thereby opening new opportunities for trait-based research in taxonomy, phylogeny, eco-physiology, and functional ecology.

  9. Operating Dedicated Data Centers - Is It Cost-Effective?

    Science.gov (United States)

    Ernst, M.; Hogue, R.; Hollowell, C.; Strecker-Kellog, W.; Wong, A.; Zaytsev, A.

    2014-06-01

    The advent of cloud computing centres such as Amazon's EC2 and Google's Computing Engine has elicited comparisons with dedicated computing clusters. Discussions on appropriate usage of cloud resources (both academic and commercial) and costs have ensued. This presentation discusses a detailed analysis of the costs of operating and maintaining the RACF (RHIC and ATLAS Computing Facility) compute cluster at Brookhaven National Lab and compares them with the cost of cloud computing resources under various usage scenarios. An extrapolation of likely future cost effectiveness of dedicated computing resources is also presented.

  10. A new mixed self-consistent field procedure

    Science.gov (United States)

    Alvarez-Ibarra, A.; Köster, A. M.

    2015-10-01

    A new approach for the calculation of three-centre electronic repulsion integrals (ERIs) is developed, implemented and benchmarked in the framework of auxiliary density functional theory (ADFT). The so-called mixed self-consistent field (mixed SCF) divides the computationally costly ERIs in two sets: far-field and near-field. Far-field ERIs are calculated using the newly developed double asymptotic expansion as in the direct SCF scheme. Near-field ERIs are calculated only once prior to the SCF procedure and stored in memory, as in the conventional SCF scheme. Hence the name, mixed SCF. The implementation is particularly powerful when used in parallel architectures, since all RAM available are used for near-field ERI storage. In addition, the efficient distribution algorithm performs minimal intercommunication operations between processors, avoiding a potential bottleneck. One-, two- and three-dimensional systems are used for benchmarking, showing substantial time reduction in the ERI calculation for all of them. A Born-Oppenheimer molecular dynamics calculation for the Na+55 cluster is also shown in order to demonstrate the speed-up for small systems achievable with the mixed SCF. Dedicated to Sourav Pal on the occasion of his 60th birthday.

  11. Coherence in Professional Education: Does It Foster Dedication and Identification?

    Science.gov (United States)

    Heggen, Kåre; Terum, Lars Inge

    2013-01-01

    This article examines the impact of professional education on students' dedication to and identification with a profession. The premise is that professional education is not only about knowledge acquisition and reasoning but also about attitudes and aspirations. In fostering dedication and identification, students' experiences of relevance seem to…

  12. Spatially-resolved EEL studies of plasmons in silver filled carbon nanotubes using a dedicated STEM

    International Nuclear Information System (INIS)

    Bangert, U; Harvey, A J; Seepujak, A

    2008-01-01

    Using a dedicated FEG STEM, we present highly spatially-resolved electron energy-loss (EEL) studies of individual multi-walled carbon nanotubes (MWCNTs), each with the inner cavity possessing regions completely filled with silver. The transmission and attenuation of graphite π-collective mode E-fields through the MWCNT walls are established. Noticeable changes in the graphite π-surface mode are witnessed, concomitant with coupling of the silver Mie mode and the graphite π-surface mode. The resulting collective mode is significantly red-shifted to below 5 eV, with considerable intensity in the visible frequency regime. It appears that silver retains its ability to enhance E-fields when surrounded by a MWCNT. Present observations lead to the possibility of collective modes propagating on graphene monolayers being tuned in frequency by the presence of a metal.

  13. Cable testing for Fermilab's high field magnets using small racetrack coils

    International Nuclear Information System (INIS)

    Feher, S.; Ambrosio, G.; Andreev, N.; Barzi, E.; Bordini, B.; Bossert, R.; Carcagno, R.; Kashikhin, V.I.; Kashikhin, V.V.; Lamm, M.J.; Novitski, I.; Orris, D.; Pischalnikov, Y.; Sylvester, C.; Tartaglia, M.; Yamada, R.; Zlobin, A.V.

    2004-01-01

    As part of the High Field Magnet program at Fermilab simple magnets have been designed utilizing small racetrack coils based on a sound mechanical structure and bladder technique developed by LBNL. Two of these magnets have been built in order to test Nb 3 Sn cables used in cos-theta dipole models. The powder-in-tube strand based cable exhibited excellent performance. It reached its critical current limit within 14 quenches. Modified jelly roll strand based cable performance was limited by magnetic instabilities at low fields as previously tested dipole models which used similar cable

  14. Experimental study of the field-of-view of neutron detectors towards thermohydraulic perturbances

    International Nuclear Information System (INIS)

    Kozma, R.

    1988-05-01

    The aim of the present study was to identify different stages of boiling during the HOR experiments at the 2 MW reactor of IRI (Interfaculty Reactor Inst.), Delft, Netherlands. The electrical heating power was increased while the flow rate was constant, thus inducing a single-phase flow, and afterwards subcooled boiling and finally developed volume boiling of the coolant in the experimental assembly. Subcooled boiling and the onset of boiling could not be detected using neutron detectors. This behaviour shows that the field of view of the NDs is very limited. The neutron noise signals remained unchanged, though at a distance of 3-10 cm developed volume boiling arose. Only the steam-packets in the slug-type flow during measurement III caused changes in the neutro noise. (author) 12 refs.; 20 figs

  15. Equipment Qualification and Environment Establishment for COTS Dedication of Safety Grade PC

    International Nuclear Information System (INIS)

    Ahn, Kwang Chul; Bin, Chang Sun; Kwon, Yoon Kwang; Kang, Shin Woo; Koh, Sung Won; Shon, Eui Chan; Jang, Hyun Doo; Song, Il Sup; Lee, Hyun Noh

    2010-08-01

    Safety grade PCs are required for protection systems of SKN 3 and 4 nuclear power plant and subsequent plants. Commercial grade item (CGI) dedication should be carried out to utilize a commercial PC as a safety grade PC of nuclear power plants. This project is aimed to perform the equipment qualification of the commercial PC, and review and improve the quality system of the PC supplier. As a result of the EQ for the CGI dedication, selected military PCs have passed the environment test, the seismic test, and the EMI test required for the digital controllers of nuclear plants. In addition, a walk-through of the quality system of the PC supplier, ISO 9001, was carried out and the quality system was improved. History data for the PC was gathered. As the analysis of the history data showed that operating experience time of the PC is longer than the plant life time, the history data could be used as an evidence of acceptance. After dedicated according to the CGI dedication process, military rugged PCs could be used for safety grade PCs

  16. Editorial for the special issue dedicated to GOPV (Global Organic Photovoltaics Conference)

    DEFF Research Database (Denmark)

    Krebs, Frederik C

    2012-01-01

    and USA dedicated to the topic of OPV that attract participants from both the USA and Europe but relatively few from Asia. It is naïve to believe that OPV should not become a global effort and that developments would accelerate faster by maintaining this geographical imbalance. The aim with the GOPV......, degradation, stability, thermo-mechanical properties, roll-to-roll processing, manufacture and industrial aspects of the field. It is my hope that you will enjoy reading this extract from the GOPV conference that comprised 48 oral presentations, 24 poster presentations and had 114 participants from 18...

  17. Preoperative staging of endometrial cancer using reduced field-of-view diffusion-weighted imaging: a preliminary study

    Energy Technology Data Exchange (ETDEWEB)

    Ota, Takashi; Hori, Masatoshi; Onishi, Hiromitsu; Sakane, Makoto; Tsuboyama, Takahiro; Tatsumi, Mitsuaki; Tomiyama, Noriyuki [Osaka University Graduate School of Medicine, Department of Diagnostic and Interventional Radiology, Suita, Osaka (Japan); Nakamoto, Atsushi; Narumi, Yoshifumi [Osaka Medical College, Department of Radiology, Osaka (Japan); Kimura, Tadashi [Osaka University Graduate School of Medicine, Department of Obstetrics and Gynaecology, Osaka (Japan)

    2017-12-15

    To compare the image quality and diagnostic performance of reduced field-of-view (rFOV) versus conventional full field-of-view (fFOV) diffusion-weighted (DW) imaging of endometrial cancer. Fifty women with endometrial cancer underwent preoperative rFOV and fFOV DW imaging. Two radiologists compared the image qualities of both techniques, and five radiologists assessed superficial and deep myometrial invasion using both techniques. The statistical analysis included the Wilcoxon signed-rank test and paired t-test for comparisons of image quality and mean diagnostic values. Distortion, tumour delineation, and overall image quality were significantly better with rFOV DW imaging, compared to fFOV DW imaging (P < 0.05); however, the former was inferior in noise (P < 0.05). Regarding superficial invasion, the mean accuracies of the techniques did not differ statistically (rFOV, 58.0% versus fFOV, 56.0%; P = 0.30). Regarding deep myometrial invasion, rFOV DW imaging yielded significantly better mean accuracy, specificity, and positive predictive values (88.4%, 97.8%, and 91.7%, respectively), compared with fFOV DW imaging (84.8%, 94.1%, and 77.4%, respectively; P = 0.009, 0.005, and 0.011, respectively). Compared with fFOV DW imaging, rFOV DW imaging yielded less distortion, improved image quality and, consequently, better diagnostic performance for deep myometrial invasion of endometrial cancer. (orig.)

  18. Is the PTW 60019 microDiamond a suitable candidate for small field reference dosimetry?

    Science.gov (United States)

    De Coste, Vanessa; Francescon, Paolo; Marinelli, Marco; Masi, Laura; Paganini, Lucia; Pimpinella, Maria; Prestopino, Giuseppe; Russo, Serenella; Stravato, Antonella; Verona, Claudio; Verona-Rinati, Gianluca

    2017-09-01

    A systematic study of the PTW microDiamond (MD) output factors (OF) is reported, aimed at clarifying its response in small fields and investigating its suitability for small field reference dosimetry. Ten MDs were calibrated under 60Co irradiation. OF measurements were performed in 6 MV photon beams by a CyberKnife M6, a Varian DHX and an Elekta Synergy linacs. Two PTW silicon diodes E (Si-D) were used for comparison. The results obtained by the MDs were evaluated in terms of absorbed dose to water determination in reference conditions and OF measurements, and compared to the results reported in the recent literature. To this purpose, the Monte Carlo (MC) beam-quality correction factor, kQMD , was calculated for the MD, and the small field output correction factors, k{{Qclin},{{Q}msr}}{{fclin},{{f}msr}} , were calculated for both the MD and the Si-D by two different research groups. An empirical function was also derived, providing output correction factors within 0.5% from the MC values calculated for all of the three linacs. A high reproducibility of the dosimetric properties was observed among the ten MDs. The experimental kQMD values are in agreement within 1% with the MC calculated ones. Output correction factors within  +0.7% and  -1.4% were obtained down to field sizes as narrow as 5 mm. The resulting MD and Si-D field factors are in agreement within 0.2% in the case of CyberKnife measurements and 1.6% in the other cases. This latter higher spread of the data was demonstrated to be due to a lower reproducibility of small beam sizes defined by jaws or multi leaf collimators. The results of the present study demonstrate the reproducibility of the MD response and provide a validation of the MC modelling of this device. In principle, accurate reference dosimetry is thus feasible by using the microDiamond dosimeter for field sizes down to 5 mm.

  19. On the impossibility of a small violation of the Pauli principle within the local quantum field theory

    International Nuclear Information System (INIS)

    Govorkov, A.B.

    1988-01-01

    It is shown that the local quantum field theory of free fields allows only the generalizations of the conventional quantizations (corresponding to the Fermi and Bose statistics) that correspond to the para-Fermi and para-Bose statistics and does not permit ''small'' violation of the Pauli principle

  20. Small animal PET: aspects of performance assessment

    International Nuclear Information System (INIS)

    Weber, Simone; Bauer, Andreas

    2004-01-01

    Dedicated small animal positron emission tomography (PET) systems are increasingly prevalent in industry (e.g. for preclinical drug development) and biological research. Such systems permit researchers to perform animal studies of a longitudinal design characterised by repeated measurements in single animals. With the advent of commercial systems, scanners have become readily available and increasingly popular. As a consequence, technical specifications are becoming more diverse, making scanner systems less broadly applicable. The investigator has, therefore, to make a decision regarding which type of scanner is most suitable for the intended experiments. This decision should be based on gantry characteristics and the physical performance. The first few steps have been taken towards standardisation of the assessment of performance characteristics of dedicated animal PET systems, though such assessment is not yet routinely implemented. In this review, we describe current methods of evaluation of physical performance parameters of small animal PET scanners. Effects of methodologically different approaches on the results are assessed. It is underscored that particular attention has to be paid to spatial resolution, sensitivity, scatter fraction and count rate performance. Differences in performance measurement methods are described with regard to commercially available systems, namely the Concorde MicroPET systems P4 and R4 and the quad-HIDAC. Lastly, consequences of differences in scanner performance parameters are rated with respect to applications of small animal PET. (orig.)

  1. Cooperative and networking strategies in small business

    CERN Document Server

    Ferreira, João

    2017-01-01

    The book aims to collect the most recent research and best practices in the cooperative and networking small business field identifying new theoretical models and describing the relationship between cooperation and networks in the small business strategy context. It examines different concepts and analytical techniques better understand the links between cooperative strategies and networks in small business. It also studies the existing economic conditions of network and strategic implications to small business from the point of view of their internal and external consistency. Cooperation and networks is a fashionable topic. It is receiving increasing attention in popular management publications, as well as specialized academic journals. Cooperation between firms and industries is a means of leveraging and aggregating knowledge also generating direct benefits in terms of innovation, productivity and competitiveness. Various options and decisions made within the framework of strategic alliances may be identifi...

  2. Solar Coronal Loops Associated with Small-scale Mixed Polarity Surface Magnetic Fields

    International Nuclear Information System (INIS)

    Chitta, L. P.; Peter, H.; Solanki, S. K.; Barthol, P.; Gandorfer, A.; Gizon, L.; Hirzberger, J.; Riethmüller, T. L.; Noort, M. van; Rodríguez, J. Blanco; Iniesta, J. C. Del Toro; Suárez, D. Orozco; Schmidt, W.; Pillet, V. Martínez; Knölker, M.

    2017-01-01

    How and where are coronal loops rooted in the solar lower atmosphere? The details of the magnetic environment and its evolution at the footpoints of coronal loops are crucial to understanding the processes of mass and energy supply to the solar corona. To address the above question, we use high-resolution line-of-sight magnetic field data from the Imaging Magnetograph eXperiment instrument on the Sunrise balloon-borne observatory and coronal observations from the Atmospheric Imaging Assembly onboard the Solar Dynamics Observatory of an emerging active region. We find that the coronal loops are often rooted at the locations with minor small-scale but persistent opposite-polarity magnetic elements very close to the larger dominant polarity. These opposite-polarity small-scale elements continually interact with the dominant polarity underlying the coronal loop through flux cancellation. At these locations we detect small inverse Y-shaped jets in chromospheric Ca ii H images obtained from the Sunrise Filter Imager during the flux cancellation. Our results indicate that magnetic flux cancellation and reconnection at the base of coronal loops due to mixed polarity fields might be a crucial feature for the supply of mass and energy into the corona.

  3. Solar Coronal Loops Associated with Small-scale Mixed Polarity Surface Magnetic Fields

    Energy Technology Data Exchange (ETDEWEB)

    Chitta, L. P.; Peter, H.; Solanki, S. K.; Barthol, P.; Gandorfer, A.; Gizon, L.; Hirzberger, J.; Riethmüller, T. L.; Noort, M. van [Max-Planck-Institut für Sonnensystemforschung, Justus-von-Liebig-Weg 3, D-37077 Göttingen (Germany); Rodríguez, J. Blanco [Grupo de Astronomía y Ciencias del Espacio, Universidad de Valencia, E-46980 Paterna, Valencia (Spain); Iniesta, J. C. Del Toro; Suárez, D. Orozco [Instituto de Astrofísica de Andalucía (CSIC), Apartado de Correos 3004, E-18080 Granada (Spain); Schmidt, W. [Kiepenheuer-Institut für Sonnenphysik, Schöneckstr. 6, D-79104 Freiburg (Germany); Pillet, V. Martínez [National Solar Observatory, 3665 Discovery Drive, Boulder, CO 80303 (United States); Knölker, M., E-mail: chitta@mps.mpg.de [High Altitude Observatory, National Center for Atmospheric Research, P.O. Box 3000, Boulder, CO 80307-3000 (United States)

    2017-03-01

    How and where are coronal loops rooted in the solar lower atmosphere? The details of the magnetic environment and its evolution at the footpoints of coronal loops are crucial to understanding the processes of mass and energy supply to the solar corona. To address the above question, we use high-resolution line-of-sight magnetic field data from the Imaging Magnetograph eXperiment instrument on the Sunrise balloon-borne observatory and coronal observations from the Atmospheric Imaging Assembly onboard the Solar Dynamics Observatory of an emerging active region. We find that the coronal loops are often rooted at the locations with minor small-scale but persistent opposite-polarity magnetic elements very close to the larger dominant polarity. These opposite-polarity small-scale elements continually interact with the dominant polarity underlying the coronal loop through flux cancellation. At these locations we detect small inverse Y-shaped jets in chromospheric Ca ii H images obtained from the Sunrise Filter Imager during the flux cancellation. Our results indicate that magnetic flux cancellation and reconnection at the base of coronal loops due to mixed polarity fields might be a crucial feature for the supply of mass and energy into the corona.

  4. Imaging design of the wide field x-ray monitor onboard the HETE satellite

    International Nuclear Information System (INIS)

    Zand, J.J.M. In'T; Fenimore, E.E.; Kawai, N.; Yoshida, A.; Matsuoka, M.; Yamauchi, M.

    1994-01-01

    The High Energy Transient Experiment (HETE), to be launched in 1995, will study Gamma-Ray Bursts in an unprecendented wide wavelength range from Gamma- and X-ray to UV wavelengths. The X-ray range (2 to 25 keV) will be covered by 2 perpendicularly oriented 1-dimensional coded aperture cameras. These instruments cover a wide field of view of 2 sr and thus have a relatively large potential to locate GRBs to a fraction of a degree, which is an order of magnitude better than BATSE. The imaging design of these coded aperture cameras relates to the design of the coded apertures and the decoding algorithm. The aperture pattern is to a large extent determined by the high background in this wide field application and the low number of pattern elements (∼100) in each direction. The result is a random pattern with an open fraction of 33%. The onboard decoding algorithm is dedicated to the localization of a single point source

  5. Online virtual isocenter based radiation field targeting for high performance small animal microirradiation

    Science.gov (United States)

    Stewart, James M. P.; Ansell, Steve; Lindsay, Patricia E.; Jaffray, David A.

    2015-12-01

    Advances in precision microirradiators for small animal radiation oncology studies have provided the framework for novel translational radiobiological studies. Such systems target radiation fields at the scale required for small animal investigations, typically through a combination of on-board computed tomography image guidance and fixed, interchangeable collimators. Robust targeting accuracy of these radiation fields remains challenging, particularly at the millimetre scale field sizes achievable by the majority of microirradiators. Consistent and reproducible targeting accuracy is further hindered as collimators are removed and inserted during a typical experimental workflow. This investigation quantified this targeting uncertainty and developed an online method based on a virtual treatment isocenter to actively ensure high performance targeting accuracy for all radiation field sizes. The results indicated that the two-dimensional field placement uncertainty was as high as 1.16 mm at isocenter, with simulations suggesting this error could be reduced to 0.20 mm using the online correction method. End-to-end targeting analysis of a ball bearing target on radiochromic film sections showed an improved targeting accuracy with the three-dimensional vector targeting error across six different collimators reduced from 0.56+/- 0.05 mm (mean  ±  SD) to 0.05+/- 0.05 mm for an isotropic imaging voxel size of 0.1 mm.

  6. An Embedded System Dedicated to Intervehicle Communication Applications

    Directory of Open Access Journals (Sweden)

    Zhou Haiying

    2010-01-01

    Full Text Available To overcome system latency and network delay is essential for intervehicle communication (IVC applications such as hazard alarming and cooperative driving. This paper proposes a low-cost embedded software system dedicated to such applications. It consists of two basic component layers: an operating system, named HEROS (hybrid event-driven and real-time multitasking operating system, and a communication protocol, named CIVIC (Communication Inter Véhicule Intelligente et Coopérative. HEROS is originally designed for wireless sensor networks (WSNs. It contains a component-based resource-aware kernel and a low-latency tuple-based communication system. Moreover, it provides a configurable event-driven and/or real-time multitasking mechanism for various embedded applications. The CIVIC is an autoconfiguration cooperative IVC protocol. It merges proactive and reactive approaches to speed up and optimize location-based routing discovery with high-mobility nodes. Currently, this embedded system has been implemented and tested. The experiment results show that the new embedded system has low system latency and network delay under the principle of small resource consumption.

  7. Preliminary experience of a three-dimensional, large-field-of-view PET scanner for the localization of partial epilepsy

    International Nuclear Information System (INIS)

    Binns, D.S.; O'Brien, T.J.; Murphy, M.; Cook, M.J.; Hicks, R.J.

    1999-01-01

    Full text: PET scanning is a useful ancillary technique in the localization of intractable partial epilepsy, but its widespread use has been limited by the high cost of traditional PET equipment and radioisotopes. The use of 3D-scanning mode with a large-field of-view PET scanner involves lower equipment costs and requires significantly lower doses of radioisotope. Our aim was to report our preliminary experience of the use of a 3-D, large-field-of-view scanner for FDG-PET studies in the localization of partial epilepsy. 31 patients (pts) with partial epilepsy were studied. The FDG-PET scans were reviewed blindly by a single reviewer without knowledge of seizure localization on structural imaging or ictal electroencephalographic (EEG) monitoring. The PET results were correlated with the localization by more traditional techniques and the results on surgery when available. A localized region of hypometabolism on FDG-PET scanning was reported in 26/31 (84%) patients (21 temporal, 5 extratemporal). This compared favourably with volumetric MRI on which 19/31 (61%) had a focal potentially epileptogenic abnormality, all of which were concordant with the PET localization. PET was concordant with ictal EEG onset in all 22 patients with localizing studies, including 5 pts with normal MRI. PET demonstrated localized hypometabolism in 4/5 pts with non-localizing ictal EEG and was concordant in both pts with abnormal MRI in this group. PET was considered normal in 4 pts, including 3 pts with normal MRI but localizing EEG and 1 pt without EEG or MRI abnormality. One pt with a localizing EEG and normal MRI was felt to have bitemporal hypometabolism. Five patients have subsequently had resective epilepsy surgery with 4 currently seizure-free and 1 significantly improved. Four patients are planned for surgery in the near future. In conclusion, FDG-PET using a 3-D, large-field-of view PET scanner provides sensitive and specific localization in partial epilepsy, and may provide a

  8. State-of-the-art of small animal imaging with high-resolution SPECT

    International Nuclear Information System (INIS)

    Nikolaus, S.; Wirrwar, A.; Antke, C.; Kley, K.; Mueller, H.W.

    2005-01-01

    During the recent years, in vivo imaging of small animals using SPECT has become of growing relevance. Along with the development of dedicated high-resolution small animal SPECT cameras, an increasing number of conventional clinical scanners has been equipped with single or multipinhole collimators. This paper reviews the small animal tomographs, which are operating at present and compares their performance characteristics. Furthermore, we describe the in vivo imaging studies, which have been performed so far with the individual scanners and survey current approaches to optimize molecular imaging with small animal SPECT. (orig.)

  9. The Integral Field View of the Orion Nebula

    Directory of Open Access Journals (Sweden)

    Adal Mesa-Delgado

    2014-01-01

    Full Text Available This paper reviews the major advances achieved in the Orion Nebula through the use of integral field spectroscopy (IFS. Since the early work of Vasconcelos and collaborators in 2005, this technique has facilitated the investigation of global properties of the nebula and its morphology, providing new clues to better constrain its 3D structure. IFS has led to the discovery of shock-heated zones at the leading working surfaces of prominent Herbig-Haro objects as well as the first attempt to determine the chemical composition of Orion protoplanetary disks, also known as proplyds. The analysis of these morphologies using IFS has given us new insights into the abundance discrepancy problem, a long-standing and unresolved issue that casts doubt on the reliability of current methods used for the determination of metallicities in the universe from the analysis of H II regions. Results imply that high-density clumps and high-velocity flows may play an active role in the production of such discrepancies. Future investigations based on the large-scale IFS mosaic of Orion will be very valuable for exploring how the integrated effect of small-scale structures may have impact at larger scales in the framework of star-forming regions.

  10. Technology challenges in small animal PET imaging

    International Nuclear Information System (INIS)

    Lecomte, Roger

    2004-01-01

    Positron Emission Tomography (PET) is a non-invasive nuclear imaging modality allowing biochemical processes to be investigated in vivo with sensitivity in the picomolar range. For this reason, PET has the potential to play a major role in the emerging field of molecular imaging by enabling the study of molecular pathways and genetic processes in living animals non-invasively. The challenge is to obtain a spatial resolution that is appropriate for rat and mouse imaging, the preferred animal models for research in biology, while achieving a sensitivity adequate for real-time measurement of rapid dynamic processes in vivo without violating tracer kinetic principles. An overview of the current state of development of dedicated small animal PET scanners is given, and selected applications are reported and discussed with respect to performance and significance to research in biology

  11. Multimodality Registration without a Dedicated Multimodality Scanner

    Directory of Open Access Journals (Sweden)

    Bradley J. Beattie

    2007-03-01

    Full Text Available Multimodality scanners that allow the acquisition of both functional and structural image sets on a single system have recently become available for animal research use. Although the resultant registered functional/structural image sets can greatly enhance the interpretability of the functional data, the cost of multimodality systems can be prohibitive, and they are often limited to two modalities, which generally do not include magnetic resonance imaging. Using a thin plastic wrap to immobilize and fix a mouse or other small animal atop a removable bed, we are able to calculate registrations between all combinations of four different small animal imaging scanners (positron emission tomography, single-photon emission computed tomography, magnetic resonance, and computed tomography [CT] at our disposal, effectively equivalent to a quadruple-modality scanner. A comparison of serially acquired CT images, with intervening acquisitions on other scanners, demonstrates the ability of the proposed procedures to maintain the rigidity of an anesthetized mouse during transport between scanners. Movement of the bony structures of the mouse was estimated to be 0.62 mm. Soft tissue movement was predominantly the result of the filling (or emptying of the urinary bladder and thus largely constrained to this region. Phantom studies estimate the registration errors for all registration types to be less than 0.5 mm. Functional images using tracers targeted to known structures verify the accuracy of the functional to structural registrations. The procedures are easy to perform and produce robust and accurate results that rival those of dedicated multimodality scanners, but with more flexible registration combinations and while avoiding the expense and redundancy of multimodality systems.

  12. DARE: a dedicated aerosols retrieval instrument

    NARCIS (Netherlands)

    Court, A.J.; Smorenburg, K.; Courrèges-Lacoste, G.B.; Visser, H.; Leeuw, G. de; Decae, R.

    2004-01-01

    Satellite remote sensing of aerosols is a largely unresolved problem. A dedicated instrument aimed at aerosols would be able to reduce the large uncertainties connected to this kind of remote sensing. TNO is performing a study of a space based instrument for aerosol measurements, together with the

  13. Relationship Between Motor Vehicle Collisions and Results of Perimetry, Useful Field of View, and Driving Simulation in Drivers With Glaucoma

    NARCIS (Netherlands)

    Tatham, AJ; Boer, E.R.; Gracitelli, CPB; Rosen, PN; Medeiros, FA

    2015-01-01

    Purpose: To examine the relationship between Motor Vehicle Collisions (MVCs) in
    drivers with glaucoma and standard automated perimetry (SAP), Useful Field of View
    (UFOV), and driving simulator assessment of divided attention.
    Methods: A cross-sectional study of 153 drivers from the

  14. Effects of small magnetic fields on the critical current of thin films

    International Nuclear Information System (INIS)

    Passos, Wagner de Assis Cangussu; Lisboa-Filho, Paulo Noronha; Ortiz, Wilson Aires; Kang, W.N.; Choi, Eun-Mi; Hyeong-Jin, Kim; Lee, Sung-Ik Lee

    2002-01-01

    Full text: Magnetic fields applied perpendicularly to superconducting thin films may produce dendritic patterns, where penetrated and Meissner regions coexist, as observed in Nb, YBaCuO and MgB 2 [1]. A temperature-dependent limiting-field, Hd(T), separates the dendritic mode from a critical-state-like penetration regime. Due to large demagnetizing factors in the perpendicular geometry, small fields may be enough to drive portions of the sample into the mixed state. Lack of symmetry and local defects might then permeate the dendritic mode. Hd(T) is related[2] to the bulk lower critical field, Hc1, which depends on the in-plane current density, J. Not surprisingly, Hd is depressed by J[3]. The dendritic mode can be detected by the AC-susceptibility: penetrated fingers act as intergranular material, and the imaginary component peaks at Tc-inter(J). Films of 0.2-0.4 microns, with millimeter lateral sizes, develop dendrites when submitted to Earth's field[2], what limits the critical current, J c . This contribution studies how J c is affected by field-induced granularity in thin films. 1. C. A. Duran et al., PRB 52 (1995) 75; P. Leiderer et al., PRL. 71 (1993) 2646; T.H. Johansen et al., Supercond. Sci. Technol. 14 (2001) 1. 2. W. A. Ortiz et al., Physica C 361 (2001) 267. 3. A. V. Bobyl et al., cond-mat/0201260, submitted to APL

  15. Dosimetric verification of small fields in the lung using lung-equivalent polymer gel and Monte Carlo simulation

    Directory of Open Access Journals (Sweden)

    Nahideh Gharehaghaji

    2018-01-01

    Conclusion: Our study showed that the dose reduction with small fields in the lung was very high. Thus, inaccurate prediction of absorbed dose inside the lung and also lung/soft-tissue interfaces with small photon beams may lead to critical consequences for treatment outcome.

  16. Dedicating Fermilab's Collider

    International Nuclear Information System (INIS)

    Anon.

    1986-01-01

    It was a bold move to have a fullscale dedication ceremony for the new proton-antiproton Collider at the Fermilab Tevatron on 13 October, two days before the first collisions were seen. However the particles dutifully behaved as required, and over the following weekend the Collider delivered its goods at a total energy of 1600 GeV, significantly boosting the world record for laboratory collisions

  17. 20 CFR 416.1247 - Exclusion of a dedicated account in a financial institution.

    Science.gov (United States)

    2010-04-01

    ... financial institution. 416.1247 Section 416.1247 Employees' Benefits SOCIAL SECURITY ADMINISTRATION... a dedicated account in a financial institution. (a) General. In determining the resources of an individual (or spouse, if any), the funds in a dedicated account in a financial institution established and...

  18. Design of UHECR telescope with 1 arcmin resolution and 50 deg. field of view

    CERN Document Server

    Sasaki, M; Asaoka, Y

    2002-01-01

    A new telescope design based on Baker-Nunn optics is proposed for observation of ultra-high-energy cosmic rays (UHECRs). The optical system has an image resolution better than 0.02 deg. within a wide field of view of 50 deg. angular diameter. When combined with a high-quality imaging device, the proposed design enables the directions of UHECRs and high-energy neutrinos to be determined with an accuracy better than 1 arcmin. The outstanding resolution of this telescope allows charge-separated cosmic-rays to be resolved and the source to be determined accurately. This marked improvement in angular resolution will allow the multi-wavelength and 'multi-particle' observations of astronomical objects through collaboration with established astronomical observations.

  19. Key Notes on a Geometric Theory of Fields

    Directory of Open Access Journals (Sweden)

    Bruchholz U. E.

    2009-04-01

    Full Text Available The role of potentials and sources in electromagnetic and gravitational fields is investi- gated. A critical analysis leads to the result that sources have to be replaced by integra- tion constants. The existence of spatial boundaries gives reasons for this step. Potentials gain physical relevance first with it. The common view, that fields are “generated” by sources, appears as not tenable. Fields do exist by their own. These insights as well as results from numerical simulations force the conclusion that a Riemannian-geometrical background of electromagnetism and even quantum phenomena cannot be excluded. Nature could differ from abstract geometry in a way that distances and intervals never become infinitesimally small.

  20. [F-18]FDG imaging of head and neck tumors: comparison of hybrid PET, dedicated PET and CT

    International Nuclear Information System (INIS)

    Dresel, S.; Brinkbaeumer, K.; Schmid, R.; Poepperl, G.; Hahn, K.; Szeimies, U.

    2001-01-01

    Aim: Aim of the study was to evaluate [F-18]FDG imaging of head and neck tumors using a Hybrid-PET device of the 2nd or 3rd generation. Examinations were compared to dedicated PET and Spiral-CT. Methods: 54 patients suffering from head and neck tumors were examined using dedicated PET and Hybrid-PET after injection of 185-350 MBq [F-18]FDG. Examinations were carried out on the dedicated PET first followed by a scan on the Hybrid-PET. Dedicated PET was acquired in 3D mode, Hybrid-PET was performed in list mode using an axial filter. Reconstruction of data was performed iteratively on both, dedicated PET and Hybrid-PET. All patients received a CT scan in multislice technique. All finding have been verified by the goldstandard histology or in case of negative histology by follow up. Results: Using dedicated PET the primary or recurrent lesion was correctly diagnosed in 47/48 patients, using Hybrid-PET in 46/48 patients and using CT in 25/48 patients. Metastatic disease in cervical lymph nodes was diagnosed in 17/18 patients with dedicated PET, in 16/18 patients with Hybrid-PET and in 15/18 with CT. False positive results with regard to lymph node metastasis were seen with one patient for dedicated PET and Hybrid-PET, respectively, and with 18 patients for CT. In a total of 11 patients unknown metastastic lesions were seen with dedicated PET and with Hybrid-PET elsewhere in the body. Additional malignant disease other than the head and neck tumor was found in 4 patients. Conclusion: Using Hybrid-PET for [F-18]FDG imaging reveals a loss of sensitivity and specificity of about 1-5% as compared to dedicated PET in head and neck tumors. [F-18]FDG PET with both, dedicated PET and Hybrid-PET is superior to CT in the diagnosis of primary or recurrent lesions as well as in the assessment of lymph node involvement. (orig.) [de

  1. President Roosevelt's 1940 Dedication of the First NCI Building

    Science.gov (United States)

    Watch this video excerpt of the dedication of the National Institute of Health, October 31, 1940. President Roosevelt spoke of the importance of the National Cancer Institute, which would be located in Building 6.

  2. Simulation of a small molecule analogue of a lithium ionomer in an external electric field

    Energy Technology Data Exchange (ETDEWEB)

    Waters, Sara M.; McCoy, John D., E-mail: mccoy@nmt.edu; Brown, Jonathan R. [Department of Materials Engineering, New Mexico Institute of Mining and Technology, Socorro, New Mexico 87801 (United States); Frischknecht, Amalie L. [Sandia National Laboratories, Albuquerque, New Mexico 87185 (United States)

    2014-01-07

    We have investigated the ion dynamics in lithium-neutralized 2-pentylheptanoic acid, a small molecule analogue of a precise poly(ethylene-co-acrylic acid) lithium ionomer. Atomistic molecular dynamics simulations were performed in an external electric field. The electric field causes alignment of the ionic aggregates along the field direction. The energetic response of the system to an imposed oscillating electric field for a wide range of frequencies was tracked by monitoring the coulombic contribution to the energy. The susceptibility found in this manner is a component of the dielectric susceptibility typically measured experimentally. A dynamic transition is found and the frequency associated with this transition varies with temperature in an Arrhenius manner. The transition is observed to be associated with rearrangements of the ionic aggregates.

  3. The Dedicated Aerosol Retrieval Experiment (DARE): scientific requirements for a dedicated satellite instrument to measure atmospheric aerosols

    NARCIS (Netherlands)

    Decae, R.; Courrèges-Lacoste, G.B.; Leeuw, G. de

    2004-01-01

    DARE (Dedicated Aerosol Retrieval Experiment) is a study to design an instrument for accurate remote sensing of aerosol properties from space. DARE combines useful properties of several existing instruments like TOMS, GOME, ATSR and POLDER. It has a large wavelength range, 330 to 1000 nm, to

  4. Summary of the 1982 small tokamak users meeting

    International Nuclear Information System (INIS)

    Sprott, J.C.

    1982-11-01

    On November 1, 1982, the sixth in a series of approximately annual meetings of the users of small tokamaks was held in conjunction with the APS Division of Plasma Physics meeting at New Orleans. The meeting lasted three hours, with 34 people attending. The interest was on strengthening the ties between the small tokamaks and the large tokamaks. Accordingly, the latest meeting was dedicated to this theme, and in contrast to previous meetings, a few representatives from the large tokamaks were invited to attend and make presentations. Summaries of the various talks are included

  5. Is the size of the useful field of view affected by postural demands associated with standing and stepping?

    Science.gov (United States)

    Reed-Jones, James G; Reed-Jones, Rebecca J; Hollands, Mark A

    2014-04-30

    The useful field of view (UFOV) is the visual area from which information is obtained at a brief glance. While studies have examined the effects of increased cognitive load on the visual field, no one has specifically looked at the effects of postural control or locomotor activity on the UFOV. The current study aimed to examine the effects of postural demand and locomotor activity on UFOV performance in healthy young adults. Eleven participants were tested on three modified UFOV tasks (central processing, peripheral processing, and divided-attention) while seated, standing, and stepping in place. Across all postural conditions, participants showed no difference in their central or peripheral processing. However, in the divided-attention task (reporting the letter in central vision and target location in peripheral vision amongst distracter items) a main effect of posture condition on peripheral target accuracy was found for targets at 57° of eccentricity (p=.037). The mean accuracy reduced from 80.5% (standing) to 74% (seated) to 56.3% (stepping). These findings show that postural demands do affect UFOV divided-attention performance. In particular, the size of the useful field of view significantly decreases when stepping. This finding has important implications for how the results of a UFOV test are used to evaluate the general size of the UFOV during varying activities, as the traditional seated test procedure may overestimate the size of the UFOV during locomotor activities. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  6. Fuel density effect on near nozzle flow field in small laminar coflow diffusion flames

    KAUST Repository

    Xiong, Yuan

    2015-01-01

    Flow characteristics in small coflow diffusion flames were investigated with a particular focus on the near-nozzle region and on the buoyancy force exerted on fuels with densities lighter and heavier than air (methane, ethylene, propane, and n-butane). The flow-fields were visualized through the trajectories of seed particles. The particle image velocimetry technique was also adopted for quantitative velocity field measurements. The results showed that the buoyancy force exerted on the fuel as well as on burnt gas significantly distorted the near-nozzle flow-fields. In the fuels with densities heavier than air, recirculation zones were formed very close to the nozzle, emphasizing the importance of the relative density of the fuel to that of the air on the flow-field. Nozzle heating influenced the near-nozzle flow-field particularly among lighter fuels (methane and ethylene). Numerical simulations were also conducted, focusing specifically on the effect of specifying inlet boundary conditions for fuel. The results showed that a fuel inlet boundary with a fully developed velocity profile for cases with long tubes should be specified inside the fuel tube to permit satisfactory prediction of the flow-field. The calculated temperature fields also indicated the importance of the selection of the location of the inlet boundary, especially in testing various combustion models that include soot in small coflow diffusion flames. © 2014 The Combustion Institute.

  7. Dedicated training in adult education among otolaryngology faculty.

    Science.gov (United States)

    McMains, Kevin C; Peel, Jennifer

    2014-12-01

    Most faculty members undergo ad hoc training in education. This survey was developed to assess the prevalence and type of dedicated training in education received by academic otolaryngology-head and neck surgery (OTO-HNS) faculty in the United States. Survey. An 11-item survey was developed to assess the prevalence of dedicated instruction in education theory and practice, the types of instruction received, and the barriers to receiving instruction. The survey was sent to all OTO-HNS program directors for distribution among their respective faculty. A total of 216 responses were received. Seventy respondents (32.7%) serve as program director, associate program director, or assistant program director in their respective programs. Forty-six respondents (21.8%) had received dedicated training in education. Of the respondents who described the type of education training received, 48.7% participated in didactics/seminar, 35.9% in degree/certificate programs, 10.3% in multimodality training, and 5.1% online training. Among the barriers encountered to participation in instruction in education, time/productivity pressures was the most commonly cited reason (60.2%), followed by not knowing about the opportunity to receive training (36.4%), lack of departmental support (26.2%), lack of available training (22.3%), and the perception that such training would not be useful (7.8%). Presently, only a minority of surveyed academic otolaryngologists in the United States have received any dedicated instruction in the theory and practice of education. Personal, departmental, and institutional barriers exist in many practice environments that hinder otolaryngology faculty from participating in education training. N/A. © 2014 The American Laryngological, Rhinological and Otological Society, Inc.

  8. Field emission electronics

    CERN Document Server

    Egorov, Nikolay

    2017-01-01

    This book is dedicated to field emission electronics, a promising field at the interface between “classic” vacuum electronics and nanotechnology. In addition to theoretical models, it includes detailed descriptions of experimental and research techniques and production technologies for different types of field emitters based on various construction principles. It particularly focuses on research into and production of field cathodes and electron guns using recently developed nanomaterials and carbon nanotubes. Further, it discusses the applications of field emission cathodes in new technologies such as light sources, flat screens, microwave and X-ray devices.

  9. Experience Innovation for Small Food and Tourism Firms

    DEFF Research Database (Denmark)

    Eriksen, Safania Normann

    2015-01-01

    This article focuses on experience innovation as a means to create value for small food and tourism firms in rural areas. Innovation is viewed as an essential part of experience staging. However, research on innovation in the experience economy literature constitutes an immature field of study...... that requires further investigation. The article seeks to address this gap by investigating how small food and tourism firms can enhance experience innovation. The research approach is a qualitative experimental design. Methods for collecting empirical material consist of observations, semi......-structured interviews, and documents. The main contribution is a three-phased model that can inspire small food and tourism firms to generate, select, and develop new ideas for experience innovation that are aligned with their capabilities, experience DNA, and available resources....

  10. Plasmonic micropillars for precision cell force measurement across a large field-of-view

    Science.gov (United States)

    Xiao, Fan; Wen, Ximiao; Tan, Xing Haw Marvin; Chiou, Pei-Yu

    2018-01-01

    A plasmonic micropillar platform with self-organized gold nanospheres is reported for the precision cell traction force measurement across a large field-of-view (FOV). Gold nanospheres were implanted into the tips of polymer micropillars by annealing gold microdisks with nanosecond laser pulses. Each gold nanosphere is physically anchored in the center of a pillar tip and serves as a strong, point-source-like light scattering center for each micropillar. This allows a micropillar to be clearly observed and precisely tracked even under a low magnification objective lens for the concurrent and precision measurement across a large FOV. A spatial resolution of 30 nm for the pillar deflection measurement has been accomplished on this platform with a 20× objective lens.

  11. Clinical utility of scintimammography: From the Anger-camera to new dedicated devices

    Energy Technology Data Exchange (ETDEWEB)

    Schillaci, Orazio [Department of Biopathology and Diagnostic Imaging, University ' Tor Vergata' , Viale G. Mazzini 121, 00195 Rome (Italy)]. E-mail: oschil@tiscali.it; Danieli, Roberta [Department of Biopathology and Diagnostic Imaging, University ' Tor Vergata' , Viale G. Mazzini 121, 00195 Rome (Italy); Romano, Pasquale [Department of Biopathology and Diagnostic Imaging, University ' Tor Vergata' , Viale G. Mazzini 121, 00195 Rome (Italy); Cossu, Elsa [Department of Biopathology and Diagnostic Imaging, University ' Tor Vergata' , Viale G. Mazzini 121, 00195 Rome (Italy); Simonetti, Giovanni [Department of Biopathology and Diagnostic Imaging, University ' Tor Vergata' , Viale G. Mazzini 121, 00195 Rome (Italy)

    2006-12-20

    Scintimammography is a functional imaging technique which uses a radiation detection camera to detect radionuclide tracers in the patient's breasts. Tracers are designed to accumulate in tumours more than in healthy tissue: the most used are Tc-99 m sestamibi and Tc-99 m tetrofosmin. Scintimammography is useful in some clinical indications as an adjunct to mammography: it is recommended for those lesions where additional information is required to reach a definitive diagnosis. Patients with dubious mammograms may benefit from this test, as well as women with dense breasts or with implants. Scintimammography is a valuable diagnostic tool also in patients with locally advanced breast cancer for monitoring and predicting response to neoadjuvant chemotherapy. Nevertheless, using an Anger-camera this technique shows a high sensitivity only for cancers >1 cm. Since other modalities are increasingly employed for the early identification of small abnormalities, the issue of detecting small cancers is critical for the future development and clinical utility of breast imaging with radiopharmaceuticals. The use of high-resolution cameras dedicated for breast imaging is the best option to improve the detection of small cancers: they allow higher flexibility in patient positioning, and the availability of mammography-like projections. Moreover, the detector can be placed directly in contact with the breast allowing a mild compression with reduction of the breast's thickness, thus increasing the target-to-background ratio and the sensitivity. These new devices have the potential of increasing the total number of breast scintigraphies performed thereby enhancing the role of nuclear medicine in breast cancer imaging.

  12. Resonant Wave Energy Converters: Small-scale field experiments and first full-scale prototype

    International Nuclear Information System (INIS)

    Arena, Felice; Fiamma, Vincenzo; Iannolo, Roberto; Laface, Valentina; Malara, Giovanni; Romolo, Alessandra; Strati Federica Maria

    2015-01-01

    The Resonant Wave Energy Converter 3 (REWEC3) is a device belonging to the family of Oscillating Water Columns (OWCs), that can convert the energy of incident waves into electrical energy via turbines. In contrast to classical OWCs, it incorporates a small vertical U-shaped duct to connect the water column to the open wave field. This article shows the results of a small-scale field experiment involving a REWEC3 designed for working with a 2 kW turbine. Then, the next experimental activity on a REWEC3 installed in the NOEL laboratory with the collaboration of ENEA, is presented. Finally, the first prototype of ReWEC3 under construction in Civitavecchia (Rome, Italy) is shown. The crucial features of the construction stage are discussed and some initial performances are provided. [it

  13. Development and validation of a novel large field of view phantom and a software module for the quality assurance of geometric distortion in magnetic resonance imaging.

    Science.gov (United States)

    Torfeh, Tarraf; Hammoud, Rabih; McGarry, Maeve; Al-Hammadi, Noora; Perkins, Gregory

    2015-09-01

    To develop and validate a large field of view phantom and quality assurance software tool for the assessment and characterization of geometric distortion in MRI scanners commissioned for radiation therapy planning. A purpose built phantom was developed consisting of 357 rods (6mm in diameter) of polymethyl-methacrylat separated by 20mm intervals, providing a three dimensional array of control points at known spatial locations covering a large field of view up to a diameter of 420mm. An in-house software module was developed to allow automatic geometric distortion assessment. This software module was validated against a virtual dataset of the phantom that reproduced the exact geometry of the physical phantom, but with known translational and rotational displacements and warping. For validation experiments, clinical MRI sequences were acquired with and without the application of a commercial 3D distortion correction algorithm (Gradwarp™). The software module was used to characterize and assess system-related geometric distortion in the sequences relative to a benchmark CT dataset, and the efficacy of the vendor geometric distortion correction algorithms (GDC) was also assessed. Results issued from the validation of the software against virtual images demonstrate the algorithm's ability to accurately calculate geometric distortion with sub-pixel precision by the extraction of rods and quantization of displacements. Geometric distortion was assessed for the typical sequences used in radiotherapy applications and over a clinically relevant 420mm field of view (FOV). As expected and towards the edges of the field of view (FOV), distortion increased with increasing FOV. For all assessed sequences, the vendor GDC was able to reduce the mean distortion to below 1mm over a field of view of 5, 10, 15 and 20cm radius respectively. Results issued from the application of the developed phantoms and algorithms demonstrate a high level of precision. The results indicate that this

  14. Acting with dedication and expertise: Relatives' experience of nurses' provision of care in a palliative unit.

    Science.gov (United States)

    Grøthe, Å; Biong, Stian; Grov, E K

    2015-12-01

    Admission of a cancer patient to a palliative unit when near the final stage of their disease trajectory undoubtedly impacts their relatives. The aim of our study was to illuminate and interpret relatives' lived experiences of health personnel's provision of care in a palliative ward. A phenomenological/hermeneutic approach was employed that was inspired by the philosophical tradition of Heidegger and Ricoeur and further developed by Lindseth and Nordberg. The perspectives of the narrator and the text were interpreted by highlighting relatives' views on a situation in which they have to face existential challenges. The analysis was undertaken in three steps: naïve reading, structural analysis, and comprehensive understanding, including the authors' professional experiences and theoretical background. Six subthemes appeared: the dying person, the bubble, the sight, the cover, the provision for children's needs, and the availability of immediate help. These components were further constructed into three themes: the meaning of relating, the meaning of action, and the meaning of resources. Our comprehensive understanding of the results suggests that the most important theme is "acting with dedication and expertise." The following aspects are crucial for relatives of cancer patients hospitalized in a palliative ward: time and existence, family dynamics, and care adjusted to the situation. Our study results led to reflections on the impact of how nurses behave when providing care to patients during the palliative phase, and how they interact with relatives in this situation. We found that cancer patients in a palliative unit most appreciate nurses who act with dedication and expertise.

  15. Dosimetric parameters for small field sizes using Fricke xylenol gel, thermoluminescent and film dosimeters, and an ionization chamber

    International Nuclear Information System (INIS)

    Guzman Calcina, Carmen S; Oliveira, Lucas N de; Almeida, Carlos E de; Almeida, Adelaide de

    2007-01-01

    Dosimetric measurements in small therapeutic x-ray beam field sizes, such as those used in radiosurgery, that have dimensions comparable to or smaller than the build-up depth, require special care to avoid incorrect interpretation of measurements in regions of high gradients and electronic disequilibrium. These regions occur at the edges of any collimated field, and can extend to the centre of small fields. An inappropriate dosimeter can result in an underestimation, which would lead to an overdose to the patient. We have performed a study of square and circular small field sizes of 6 MV photons using a thermoluminescent dosimeter (TLD), Fricke xylenol gel (FXG) and film dosimeters. PMMA phantoms were employed to measure lateral beam profiles (1 x 1, 3 x 3 and 5 x 5 cm 2 for square fields and 1, 2 and 4 cm diameter circular fields), the percentage depth dose, the tissue maximum ratio and the output factor. An ionization chamber (IC) was used for calibration and comparison. Our results demonstrate that high resolution FXG, TLD and film dosimeters agree with each other, and that an ionization chamber, with low lateral resolution, underestimates the absorbed dose. Our results show that, when planning small field radiotherapy, dosimeters with adequate lateral spatial resolution and tissue equivalence are required to provide an accurate basic beam data set to correctly calculate the absorbed dose in regions of electronic disequilibrium

  16. Adaptive Scanning Optical Microscope (ASOM): A multidisciplinary optical microscope design for large field of view and high resolution imaging

    NARCIS (Netherlands)

    Potsaid, B.; Bellouard, Y.J.; Wen, J.T.

    2005-01-01

    From micro-assembly to biological observation, the optical microscope remains one of the most important tools for observing below the threshold of the naked human eye. However, in its conventional form, it suffers from a trade-off between resolution and field of view. This paper presents a new

  17. Image quality assessment of three limited field-of-view cone-beam computed tomography devices in endodontics

    International Nuclear Information System (INIS)

    Tran, Michel

    2015-01-01

    Since the beginning of Cone Beam Computed Tomography (CBCT) in dento-maxillo-facial radiology, many CBCT devices with different technical aspects and characteristics were produced. Technical variations between CBCT and acquisition settings could involve image quality differences. In order to compare the performance of three limited field-of-view CBCT devices, an objective and subjective evaluation of image quality was carried out using an ex-vivo phantom, which combines both diagnostic and technical features. A significant difference in image quality was found between the five acquisition protocols of the study. (author) [fr

  18. Quality assurance requirements for dedication process in Angra 1

    Energy Technology Data Exchange (ETDEWEB)

    Baliza, Ana Rosa, E-mail: baliza@eletronuclear.gov.br [Eletrobras Termonuclear S.A. (ELETRONUCLEAR), Angra dos Reis, RJ (Brazil). Departamento GQO.G; Morghi, Youssef, E-mail: ymo@cdtn.br [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2015-07-01

    In Brazil the regulatory body is CNEN (Comissao Nacional de Energia Nuclear), according to its requirements, when there is not a Brazilian standard, the utilities shall follow the requirements of the designer. For Angra 1, the designer is an American company - Westinghouse. So, the requirements for dedication of U.S. NRC (United States Nuclear Regulatory Commission) shall be applied, these requirements are in 10CFR21 - Reporting of Defects and Noncompliance. According to 10CFR21, when applied to nuclear power plants licensed dedication is an acceptance process undertaken to provide reasonable assurance that a commercial grade item to be used as a basic component will perform its intended safety function and, in this respect, is deemed equivalent to an item designed and manufactured under a quality assurance program standard for nuclear power plant. This assurance is achieved by identifying the critical characteristics of the item and verifying their acceptability by inspections, tests, or analyses by the purchaser or third-party dedicating entity. (author)

  19. Quality assurance requirements for dedication process in Angra 1

    International Nuclear Information System (INIS)

    Baliza, Ana Rosa

    2015-01-01

    In Brazil the regulatory body is CNEN (Comissao Nacional de Energia Nuclear), according to its requirements, when there is not a Brazilian standard, the utilities shall follow the requirements of the designer. For Angra 1, the designer is an American company - Westinghouse. So, the requirements for dedication of U.S. NRC (United States Nuclear Regulatory Commission) shall be applied, these requirements are in 10CFR21 - Reporting of Defects and Noncompliance. According to 10CFR21, when applied to nuclear power plants licensed dedication is an acceptance process undertaken to provide reasonable assurance that a commercial grade item to be used as a basic component will perform its intended safety function and, in this respect, is deemed equivalent to an item designed and manufactured under a quality assurance program standard for nuclear power plant. This assurance is achieved by identifying the critical characteristics of the item and verifying their acceptability by inspections, tests, or analyses by the purchaser or third-party dedicating entity. (author)

  20. A system dedicated to the viewing and handling of tomographic images obtained by magnetic resonance; Um sistema dedicado a visualizacao e manipulacao de imagens tomograficas obtidas por ressonancia magnetica

    Energy Technology Data Exchange (ETDEWEB)

    Slaets, Joan F.W.; Almeida, Lirio O.B. [Sao Paulo Univ., Sao Carlos, SP (Brazil). Inst. de Fisica e Quimica; Traina, Agma J.M. [Sao Paulo Univ., Sao Carlos, SP (Brazil). Inst. de Ciencias Matematicas

    1993-12-31

    The present work describes the development of a dedicated system to be used in visualization and manipulation of a MR images. The graphics environment as well as the tool kit were developed for the dedicated TMS34010 based hardware. The developed software offers a compact kernel with primitives to support the creation and manipulation windows and menus directly in `C` language. This work is fundamental for the implementation of a user friendly interface build to operate and visualize tomographic images. This tools are essential for the selection an archiving of images planes as used in clinical applications. (author) 9 refs., 2 figs., 1 photo; e-mail: jan, agma and lirio at uspfsc.ifqsc..usp.ansp.br

  1. A system dedicated to the viewing and handling of tomographic images obtained by magnetic resonance; Um sistema dedicado a visualizacao e manipulacao de imagens tomograficas obtidas por ressonancia magnetica

    Energy Technology Data Exchange (ETDEWEB)

    Slaets, Joan F.W.; Almeida, Lirio O.B. [Sao Paulo Univ., Sao Carlos, SP (Brazil). Inst. de Fisica e Quimica; Traina, Agma J.M. [Sao Paulo Univ., Sao Carlos, SP (Brazil). Inst. de Ciencias Matematicas

    1992-12-31

    The present work describes the development of a dedicated system to be used in visualization and manipulation of a MR images. The graphics environment as well as the tool kit were developed for the dedicated TMS34010 based hardware. The developed software offers a compact kernel with primitives to support the creation and manipulation windows and menus directly in `C` language. This work is fundamental for the implementation of a user friendly interface build to operate and visualize tomographic images. This tools are essential for the selection an archiving of images planes as used in clinical applications. (author) 9 refs., 2 figs., 1 photo; e-mail: jan, agma and lirio at uspfsc.ifqsc..usp.ansp.br

  2. A comparison of small-field tissue phantom ratio data generation methods for an Elekta Agility 6 MV photon beam.

    Science.gov (United States)

    Richmond, Neil; Brackenridge, Robert

    2014-01-01

    Tissue-phantom ratios (TPRs) are a common dosimetric quantity used to describe the change in dose with depth in tissue. These can be challenging and time consuming to measure. The conversion of percentage depth dose (PDD) data using standard formulae is widely employed as an alternative method in generating TPR. However, the applicability of these formulae for small fields has been questioned in the literature. Functional representation has also been proposed for small-field TPR production. This article compares measured TPR data for small 6 MV photon fields against that generated by conversion of PDD using standard formulae to assess the efficacy of the conversion data. By functionally fitting the measured TPR data for square fields greater than 4cm in length, the TPR curves for smaller fields are generated and compared with measurements. TPRs and PDDs were measured in a water tank for a range of square field sizes. The PDDs were converted to TPRs using standard formulae. TPRs for fields of 4 × 4cm(2) and larger were used to create functional fits. The parameterization coefficients were used to construct extrapolated TPR curves for 1 × 1 cm(2), 2 × 2-cm(2), and 3 × 3-cm(2) fields. The TPR data generated using standard formulae were in excellent agreement with direct TPR measurements. The TPR data for 1 × 1-cm(2), 2 × 2-cm(2), and 3 × 3-cm(2) fields created by extrapolation of the larger field functional fits gave inaccurate initial results. The corresponding mean differences for the 3 fields were 4.0%, 2.0%, and 0.9%. Generation of TPR data using a standard PDD-conversion methodology has been shown to give good agreement with our directly measured data for small fields. However, extrapolation of TPR data using the functional fit to fields of 4 × 4cm(2) or larger resulted in generation of TPR curves that did not compare well with the measured data. © 2013 Published by American Association of Medical Dosimetrists on behalf of American Association of Medical

  3. SU-F-E-17: A Dedicated Teaching and Research Linac as a Stepping Stone to Introduce Medical Physics to Students

    International Nuclear Information System (INIS)

    Beaulieu, L; Archambault, L; Gingras, L; Bergeron, M

    2016-01-01

    Purpose: This work describes how a non-clinical, research and teaching Linac is used as an extremely motivating and exciting way to introduce students to medical physics. Methods: The dedicated facility was inaugurated in 2014. The facility is composed of a fully equipped and functional state-of-the-art Varian TrueBeam Linac and a complete set of physics instruments and QA phantoms for the Linac and onboard imaging. The Linac bunker and treatment console are oversized such that a class of 12–15 can comfortably fit, seated if needed for longer sessions. A 3cr undergraduate laboratory course that includes medical imaging, x-ray source characterization (mAs, kVp, and filtering) and many others including an introductory Linac laboratory was created. The latter is composed of one general 4-hours session and a weekly 4-hours session for teams of two students. The general session includes a hands-on presentation of the Linac, its environment and a formal safety and radiation protection course (with an exam). Results: Since the winter of 2015, senior undergraduate (total of 15) pursuing either the medical physics or the biomedical engineering tracks can register. At the Linac, the students are allowed full control of the experiments, including set-up and irradiation. Supervisor intervention is limited to safety concerns for students or equipment. Measurements of output factors using two chambers (regular and small field) for various field sizes (1×1 to 30×30 cm 2 ) and of detailed depth-dose curves for 6 MV, 6 and 12 MeV beams are to be performed and discussed in a formal report. Conclusion: Full access to, and control of, a Linac is the high point of this course. It provides a glimpse of medical physics and generates an experimental background for those continuing to CAMPEP programs. This dedicated, non-clinical facility further enable enhance CAMPEP graduate teaching and research activities not possible with a clinical device.

  4. SU-F-E-17: A Dedicated Teaching and Research Linac as a Stepping Stone to Introduce Medical Physics to Students

    Energy Technology Data Exchange (ETDEWEB)

    Beaulieu, L; Archambault, L [CHU de Quebec - Universite Laval, Quebec, Quebec (Canada); Universite Laval, Quebec, Quebec (Canada); Gingras, L [CHU de Quebec - Universite Laval, Quebec, Quebec (Canada); Bergeron, M [CEGEP de Ste-Foy, Quebec, Quebec (Canada)

    2016-06-15

    Purpose: This work describes how a non-clinical, research and teaching Linac is used as an extremely motivating and exciting way to introduce students to medical physics. Methods: The dedicated facility was inaugurated in 2014. The facility is composed of a fully equipped and functional state-of-the-art Varian TrueBeam Linac and a complete set of physics instruments and QA phantoms for the Linac and onboard imaging. The Linac bunker and treatment console are oversized such that a class of 12–15 can comfortably fit, seated if needed for longer sessions. A 3cr undergraduate laboratory course that includes medical imaging, x-ray source characterization (mAs, kVp, and filtering) and many others including an introductory Linac laboratory was created. The latter is composed of one general 4-hours session and a weekly 4-hours session for teams of two students. The general session includes a hands-on presentation of the Linac, its environment and a formal safety and radiation protection course (with an exam). Results: Since the winter of 2015, senior undergraduate (total of 15) pursuing either the medical physics or the biomedical engineering tracks can register. At the Linac, the students are allowed full control of the experiments, including set-up and irradiation. Supervisor intervention is limited to safety concerns for students or equipment. Measurements of output factors using two chambers (regular and small field) for various field sizes (1×1 to 30×30 cm{sup 2}) and of detailed depth-dose curves for 6 MV, 6 and 12 MeV beams are to be performed and discussed in a formal report. Conclusion: Full access to, and control of, a Linac is the high point of this course. It provides a glimpse of medical physics and generates an experimental background for those continuing to CAMPEP programs. This dedicated, non-clinical facility further enable enhance CAMPEP graduate teaching and research activities not possible with a clinical device.

  5. Dedication of Stotz-Kontakt switches for Spanish utility owners

    International Nuclear Information System (INIS)

    Lopez Vergara, T.; Martin de la Torre, M.; Alminana, J.

    1996-01-01

    The Spanish Utility Owners Group commissioned Empresarios Agrupados to perform the work for the dedication of the S280 series of Stotz-KONTAKT switches and two of its possible accessories. As a results of this process, the components can be used in safety-related applications in the conditions and locations expected. This article describes the different phases of the dedication process: Technical Evaluation considering the application of switches as new or alternative elements, Acceptance Process and Purchasing Documentation. It sets out the main conclusion drawn from each phase. It also includes details of the activities performed by Empresarios Agrupados as part of the seismic qualification of components: selection of the sample to be tested, the definition of electrical tests before and after the seismic test, and the mounting, electrical powering, operating requirements and monitoring of components during seismic tests. (Author)

  6. Less gastrointestinal toxicity after adjuvant radiotherapy on a small pelvic field compared to a standard pelvic field in patients with endometrial carcinoma

    NARCIS (Netherlands)

    de Jong, Renske A.; Pras, Elisabeth; Boezen, H. Marike; van der Zee, Ate G. J.; Mourits, Marian J. E.; Arts, Henriette J. G.; Aalders, Jan G.; Slot, Annerie; Timmer, Paul R.; Hollema, Harry; Nijman, Hans W.

    Objective: Radiotherapy is associated with short-term and long-term morbidity. This study compared toxicity rates among patients with endometrial carcinoma (EC) treated with adjuvant external beam radiation therapy (EBRT) on a small pelvic field (SmPF) in comparison with a standard pelvic field

  7. Editors note, and Dedication

    Directory of Open Access Journals (Sweden)

    Laura Mugnai

    2011-12-01

    Full Text Available This Supplement to volume 50 of Phytopathologia Mediterranea contains original, peer reviewed research papers, prepared from presentations at the 7th International Workshop on Grapevine Trunk Diseases (IWGTD. This Workshop was held in Santa Cruz, Chile, 17–21 January 2010, and was organized by the International Council on Grapevine Trunk Diseases (ICGTD.  Publication of this Supplement has been financially assisted by the International Society for Plant Pathology (ISPP.This Supplementary Issue of Phytopathologia Mediterranea is dedicated to the memory of Dr Luigi Chiarappa, the founder and inspiration of the ICGTD.  

  8. Comparison of Flattening Filter (FF) and Flattening-Filter-Free (FFF) 6 MV photon beam characteristics for small field dosimetry using EGSnrc Monte Carlo code

    Science.gov (United States)

    Sangeetha, S.; Sureka, C. S.

    2017-06-01

    The present study is focused to compare the characteristics of Varian Clinac 600 C/D flattened and unflattened 6 MV photon beams for small field dosimetry using EGSnrc Monte Carlo Simulation since the small field dosimetry is considered to be the most crucial and provoking task in the field of radiation dosimetry. A 6 MV photon beam of a Varian Clinac 600 C/D medical linear accelerator operates with Flattening Filter (FF) and Flattening-Filter-Free (FFF) mode for small field dosimetry were performed using EGSnrc Monte Carlo user codes (BEAMnrc and DOSXYZnrc) in order to calculate the beam characteristics using Educated-trial and error method. These includes: Percentage depth dose, lateral beam profile, dose rate delivery, photon energy spectra, photon beam uniformity, out-of-field dose, surface dose, penumbral dose and output factor for small field dosimetry (0.5×0.5 cm2 to 4×4 cm2) and are compared with magna-field sizes (5×5 cm2 to 40×40 cm2) at various depths. The results obtained showed that the optimized beam energy and Full-width-half maximum value for small field dosimetry and magna-field dosimetry was found to be 5.7 MeV and 0.13 cm for both FF and FFF beams. The depth of dose maxima for small field size deviates minimally for both FF and FFF beams similar to magna-fields. The depths greater than dmax depicts a steeper dose fall off in the exponential region for FFF beams comparing FF beams where its deviations gets increased with the increase in field size. The shape of the lateral beam profiles of FF and FFF beams varies remains similar for the small field sizes less than 4×4 cm2 whereas it varies in the case of magna-fields. Dose rate delivery for FFF beams shows an eminent increase with a two-fold factor for both small field dosimetry and magna-field sizes. The surface dose measurements of FFF beams for small field size were found to be higher whereas it gets lower for magna-fields than FF beam. The amount of out-of-field dose reduction gets

  9. Dedication of Fermilab's LHC Remote Operations Center

    CERN Multimedia

    Claudia Marcelloni

    2007-01-01

    Fermilab's Remote Operations Center will be dedicated simultaneously at Fermilab in the U.S. and from CMS (Point 5) in Cessy, France. Speakers will include: from the U.S. DOE Undersecretary for Science Raymond Orbach and Fermilab Director Pier Oddone (U.S.); and from CERN Director General Robert Aymar, CMS Spokesperson Jim Virdee, LHC Project Leader Lyn Evans and US CMS Project Manager Joel Butler.

  10. Redesigning a collection system for "small" consumer electronics

    NARCIS (Netherlands)

    Melissen, Franciscus

    2006-01-01

    This paper establishes that the collection system within the recycling scheme for consumer electronics in the Netherlands has not been entirely successful in convincing consumers to hand in their used appliances by means of dedicated collection routes. Particularly regarding small appliances,

  11. Experimental Analysis of File Transfer Rates over Wide-Area Dedicated Connections

    Energy Technology Data Exchange (ETDEWEB)

    Rao, Nageswara S. [ORNL; Liu, Qiang [ORNL; Sen, Satyabrata [ORNL; Hinkel, Gregory Carl [ORNL; Imam, Neena [ORNL; Foster, Ian [University of Chicago; Kettimuthu, R. [Argonne National Laboratory (ANL); Settlemyer, Bradley [Los Alamos National Laboratory (LANL); Wu, Qishi [University of Memphis; Yun, Daqing [Harrisburg University

    2016-12-01

    File transfers over dedicated connections, supported by large parallel file systems, have become increasingly important in high-performance computing and big data workflows. It remains a challenge to achieve peak rates for such transfers due to the complexities of file I/O, host, and network transport subsystems, and equally importantly, their interactions. We present extensive measurements of disk-to-disk file transfers using Lustre and XFS file systems mounted on multi-core servers over a suite of 10 Gbps emulated connections with 0-366 ms round trip times. Our results indicate that large buffer sizes and many parallel flows do not always guarantee high transfer rates. Furthermore, large variations in the measured rates necessitate repeated measurements to ensure confidence in inferences based on them. We propose a new method to efficiently identify the optimal joint file I/O and network transport parameters using a small number of measurements. We show that for XFS and Lustre with direct I/O, this method identifies configurations achieving 97% of the peak transfer rate while probing only 12% of the parameter space.

  12. Operating dedicated data centers – is it cost-effective?

    International Nuclear Information System (INIS)

    Ernst, M; Hogue, R; Hollowell, C; Strecker-Kellog, W; Wong, A; Zaytsev, A

    2014-01-01

    The advent of cloud computing centres such as Amazon's EC2 and Google's Computing Engine has elicited comparisons with dedicated computing clusters. Discussions on appropriate usage of cloud resources (both academic and commercial) and costs have ensued. This presentation discusses a detailed analysis of the costs of operating and maintaining the RACF (RHIC and ATLAS Computing Facility) compute cluster at Brookhaven National Lab and compares them with the cost of cloud computing resources under various usage scenarios. An extrapolation of likely future cost effectiveness of dedicated computing resources is also presented.

  13. Entraigues, a system dedicated to industrial radiography interpretation

    International Nuclear Information System (INIS)

    Fleuet, E.; Lavayssiere, B.

    1995-01-01

    Some inspections including radiography are periodically done among the components of a nuclear power plant in order to check their integrity. Today the operator is in charge of acquiring data, of analysing and of quantifying the produced X-ray films. EDF has built a digital system called ENTRAIGUES which aims to help the processing and the interpretation of radiographic images. The hardware of ENTRAIGUES is composed of a digitizer, a dedicated image processor and a PC. The software has been designed to facilitate the analysis of X-ray images. With the inclusion of compression algorithms and automatic image procedures ENTRAIGUES has become a complete tool dedicated to digitization, processing and archiving of nuclear power plant radiographs. (authors). 2 refs

  14. Development and optimization of a beam shaper device for a mobile dedicated IOERT accelerator

    International Nuclear Information System (INIS)

    Soriani, Antonella; Iaccarino, Giuseppe; Felici, Giuseppe; Ciccotelli, Alessia; Pinnarò, Paola; Giordano, Carolina; Benassi, Marcello; D'Andrea, Marco; Bellesi, Luca; Strigari, Lidia

    2012-01-01

    Purpose: The aim of this study was to design and build a prototype beam shaper to be used on a dedicated mobile accelerator that protects organs at risk within the radiation field and conforms the beam to the target geometry during intraoperative electron radiotherapy (IOERT). A dosimetric characterization of the beam shaper device was performed based on Monte Carlo (MC) simulations, as well as experimental data, at different energies, field sizes, and source to skin distances. Methods: A mobile light intraoperative accelerator (LIAC ® , Sordina, Italy) was used. The design of the beam shaper prototype was based on MC simulations (BEAMnrc/OMEGA and DOSXYZnrc code) for a selection of materials and thicknesses, as well as for dosimetric characterization. Percentage depth dose (PDD) and profile measurements were performed using a p-type silicon diode and a commercial water phantom, while output factors were measured using a PinPoint ion chamber in a PMMA phantom. Planar doses in planes of interest were carried out using radiochromic films (Gafchromic TM EBT and EBT2) in PMMA and in a Solid Water ® phantom. Several experimental set-ups were investigated with the beam shaper device fixed on the top of the phantom, varying both the short side of the rectangular field and the air gap between the device and the phantom surface, simulating the clinical situation. The output factors (OFs) were determined using different geometrical set-ups and energies. Results: The beam shaper prototype consists of four blades sliding alongside each other and mounted on a special support at the end of the 10 cm diameter PMMA circular applicator. Each blade is made of an upper layer of 2.6 cm of Teflon ® and a lower layer of 8 mm of stainless steel. All rectangles inscribed in a 5 cm diameter can be achieved in addition to any “squircle-shaped” field. When one side of the rectangular field is held constant and the second side is reduced, both R 50 and R max move towards the phantom

  15. A Dedicated Space Observatory For Time-domain Solar System Science

    Science.gov (United States)

    Wong, Michael H.; Ádámkovics, M.; Benecchi, S.; Bjoraker, G.; Clarke, J. T.; de Pater, I.; Hendrix, A. R.; Marchis, F.; McGrath, M.; Noll, K.; Rages, K. A.; Retherford, K.; Smith, E. H.; Strange, N. J.

    2009-09-01

    Time-variable phenomena with scales ranging from minutes to decades have led to a large fraction of recent advances in many aspects of solar system science. We present the scientific motivation for a dedicated space observatory for solar system science. This facility will ideally conduct repeated imaging and spectroscopic observations over a period of 10 years or more. It will execute a selection of long-term projects with interleaved scheduling, resulting in the acquisition of data sets with consistent calibration, long baselines, and optimized sampling intervals. A sparse aperture telescope would be an ideal configuration for the mission, trading decreased sensitivity for reduced payload mass, while preserving spatial resolution. Ultraviolet capability is essential, especially once the Hubble Space Telescope retires. Specific investigations will include volcanism and cryovolcanism (on targets including Io, Titan, Venus, Mars, and Enceladus); zonal flow, vortices, and storm evolution on the giant planets; seasonal cycles in planetary atmospheres; mutual events and orbit determination of multiple small solar system bodies; auroral activity and solar wind interactions; and cometary evolution. The mission will produce a wealth of data products--such as multi-year time-lapse movies of planetary atmospheres--with significant education and public outreach potential. Existing and planned ground- and space-based facilities are not suitable for these time-domain optimized planetary dynamics studies for numerous reasons, including: oversubscription by astrophysical users, field-of-regard limitations, sensitive detector saturation limits that preclude bright planetary targets, and limited mission duration. The abstract author list is a preliminary group of scientists who have shown interest in prior presentations on this topic; interested parties may contact the lead author by 1 September to sign the associated Planetary Science Decadal Survey white paper or by 1 October to

  16. A Very High Spatial Resolution Detector for Small Animal PET

    International Nuclear Information System (INIS)

    Kanai Shah, M.S.

    2007-01-01

    Positron Emission Tomography (PET) is an in vivo analog of autoradiography and has the potential to become a powerful new tool in imaging biological processes in small laboratory animals. PET imaging of small animals can provide unique information that can help in advancement of human disease models as well as drug development. Clinical PET scanners used for human imaging are bulky, expensive and do not have adequate spatial resolution for small animal studies. Hence, dedicated, low cost instruments are required for conducting small animal studies with higher spatial resolution than what is currently achieved with clinical as well as dedicated small animal PET scanners. The goal of the proposed project is to investigate a new all solid-state detector design for small animal PET imaging. Exceptionally high spatial resolution, good timing resolution, and excellent energy resolution are expected from the proposed detector design. The Phase I project was aimed at demonstrating the feasibility of producing high performance solid-state detectors that provide high sensitivity, spatial resolution, and timing characteristics. Energy resolution characteristics of the new detector were also investigated. The goal of the Phase II project is to advance the promising solid-state detector technology for small animal PET and determine its full potential. Detectors modules will be built and characterized and finally, a bench-top small animal PET system will be assembled and evaluated

  17. Augmented Reality Imaging System: 3D Viewing of a Breast Cancer.

    Science.gov (United States)

    Douglas, David B; Boone, John M; Petricoin, Emanuel; Liotta, Lance; Wilson, Eugene

    2016-01-01

    To display images of breast cancer from a dedicated breast CT using Depth 3-Dimensional (D3D) augmented reality. A case of breast cancer imaged using contrast-enhanced breast CT (Computed Tomography) was viewed with the augmented reality imaging, which uses a head display unit (HDU) and joystick control interface. The augmented reality system demonstrated 3D viewing of the breast mass with head position tracking, stereoscopic depth perception, focal point convergence and the use of a 3D cursor and joy-stick enabled fly through with visualization of the spiculations extending from the breast cancer. The augmented reality system provided 3D visualization of the breast cancer with depth perception and visualization of the mass's spiculations. The augmented reality system should be further researched to determine the utility in clinical practice.

  18. Performance of TCP over UMTS common and dedicated channels

    NARCIS (Netherlands)

    Lo, Anthony; Heijenk, Geert; Bruma, Cezar; Gameiro, A.

    2003-01-01

    Universal Mobile Telecommunications System (UMTS) is a third-generation cellular network that enables high-speed wireless Internet access. This paper investigates the performance of Transmission Control Protocol (TCP) over UMTS utilizing a common and four dedicated transport channels with bit rates

  19. Combined large field-of-view MRA and time-resolved MRA of the lower extremities: Impact of acquisition order on image quality

    International Nuclear Information System (INIS)

    Riffel, Philipp; Haneder, Stefan; Attenberger, Ulrike I.; Brade, Joachim; Schoenberg, Stefan O.; Michaely, Henrik J.

    2012-01-01

    Purpose: Different approaches exist for hybrid MRA of the calf station. So far, the order of the acquisition of the focused calf MRA and the large field-of-view MRA has not been scientifically evaluated. Therefore the aim of this study was to evaluate if the quality of the combined large field-of-view MRA (CTM MR angiography) and time-resolved MRA with stochastic interleaved trajectories (TWIST MRA) depends on the order of acquisition of the two contrast-enhanced studies. Methods: In this retrospective study, 40 consecutive patients (mean age 68.1 ± 8.7 years, 29 male/11 female) who had undergone an MR angiographic protocol that consisted of CTM-MRA (TR/TE, 2.4/1.0 ms; 21° flip angle; isotropic resolution 1.2 mm; gadolinium dose, 0.07 mmol/kg) and TWIST-MRA (TR/TE 2.8/1.1; 20° flip angle; isotropic resolution 1.1 mm; temporal resolution 5.5 s, gadolinium dose, 0.03 mmol/kg), were included. In the first group (group 1) TWIST-MRA of the calf station was performed 1–2 min after CTM-MRA. In the second group (group 2) CTM-MRA was performed 1–2 min after TWIST-MRA of the calf station. The image quality of CTM-MRA and TWIST-MRA were evaluated by 2 two independent radiologists in consensus according to a 4-point Likert-like rating scale assessing overall image quality on a segmental basis. Venous overlay was assessed per examination. Results: In the CTM-MRA, 1360 segments were included in the assessment of image quality. CTM-MRA was diagnostic in 95% (1289/1360) of segments. There was a significant difference (p < 0.0001) between both groups with regard to the number of segments rated as excellent and moderate. The image quality was rated as excellent in group 1 in 80% (514/640 segments) and in group 2 in 67% (432/649), respectively (p < 0.0001). In contrast, the image quality was rated as moderate in the first group in 5% (33/640) and in the second group in 19% (121/649) respectively (p < 0.0001). The venous overlay was disturbing in 10% in group 1 and 20% in group

  20. Influence of external resonant magnetic perturbation field on edge plasma of small tokamak HYBTOK-II

    Energy Technology Data Exchange (ETDEWEB)

    Hayashi, Y., E-mail: hayashi-yuki13@ees.nagoya-u.ac.jp [Nagoya University, Furo-cho, Chikusa-ku, Nagoya, Aichi 464-8603 (Japan); Suzuki, Y.; Ohno, N. [Nagoya University, Furo-cho, Chikusa-ku, Nagoya, Aichi 464-8603 (Japan); Okamoto, M. [Ishikawa National College of Technology, Kitachujo, Tsubata-cho, Kahoku-gun, Ishikawa 929-0392 (Japan); Kikuchi, Y. [University of Hyogo, 2167 Shosha, Himeji, Hyogo 671-2280 (Japan); Sakakibara, S.; Watanabe, K.; Takemura, Y. [National Institute for Fusion Science, 322-6 Oroshi-cho, Toki, Gifu 509-5292 (Japan)

    2015-08-15

    Radial profile of externally applied resonant magnetic perturbation (RMP) field with mode numbers of m = 6 and n = 2 in a small tokamak device HYBTOK-II have been investigated using a magnetic probe array, which is able to measure the radial profile of magnetic field perturbation induced by applying RMP. Results of RMP penetration into the plasma show that the RMP decreased toward the plasma center, while they were amplified around the resonant surface with a safety factor q = 3 due to the formation of magnetic islands. This suggests that RMP fields for controlling edge plasmas may trigger some kind of MHD instabilities. In addition, simulation results, based on a linearized four-field model, which agrees with the experimental ones, indicates that the penetration and amplification process of RMP strongly depend on a Doppler-shifted frequency between the RMP and plasma rotation.

  1. WE-FG-207A-01: Introduction to Dedicated Breast CT - Early Studies

    International Nuclear Information System (INIS)

    Vedantham, S.

    2016-01-01

    investigating dedicated breast CT. The development of large-area flat-panel detectors with field-of-view sufficient to image the entire breast in each projection enabled development of flat-panel cone-beam breast CT. More recently, the availability of complimentary metal-oxide semiconductor (CMOS) detectors with lower system noise and finer pixel pitch, combined with the development of x-ray tubes with focal spot dimensions similar to mammography systems, has shown improved spatial resolution and could improve visualization of microcalcifications. These technological developments promise clinical translation of low-dose cone-beam breast CT. Dedicated photon-counting breast CT (pcBCT) systems represent a novel detector design, which provide high spatial resolution (∼ 100µm) and low mean glandular dose (MGD). The CdTe-based direct conversion detector technology was previously evaluated and confirmed by simulations and basic experiments on laboratory setups [Kalender et al., Eur Radiol 22: 1–8, 2012]. Measurements of dose, technical image quality parameters, and surgical specimens on a pcBCT scanner have been completed. Comparative evaluation of surgical specimens showed that pcBCT outperformed mammography and digital breast tomosynthesis with respect to 3D spatial resolution, detectability of calcifications, and soft tissue delineation. Major barriers to widespread clinical use of BCT relate to radiation dose, imaging of microcalcifications, and adequate coverage of breast tissue near the chest wall. Adequate chest wall coverage is also technically challenging but recent progress in x-ray tube, detector and table design now enables full breast coverage in the majority of patients. At this time, BCT has been deemed to be suitable for diagnostic imaging but not yet for screening. The mean glandular dose (MGD) from BCT has been reported to be between 5.7 to 27.8 mGy, and this range is comparable to, and within the range of, the MGD of 2.6 to 31.6 mGy in diagnostic mammography

  2. WE-FG-207A-01: Introduction to Dedicated Breast CT - Early Studies

    Energy Technology Data Exchange (ETDEWEB)

    Vedantham, S. [University of Massachusetts Medical School (United States)

    2016-06-15

    investigating dedicated breast CT. The development of large-area flat-panel detectors with field-of-view sufficient to image the entire breast in each projection enabled development of flat-panel cone-beam breast CT. More recently, the availability of complimentary metal-oxide semiconductor (CMOS) detectors with lower system noise and finer pixel pitch, combined with the development of x-ray tubes with focal spot dimensions similar to mammography systems, has shown improved spatial resolution and could improve visualization of microcalcifications. These technological developments promise clinical translation of low-dose cone-beam breast CT. Dedicated photon-counting breast CT (pcBCT) systems represent a novel detector design, which provide high spatial resolution (∼ 100µm) and low mean glandular dose (MGD). The CdTe-based direct conversion detector technology was previously evaluated and confirmed by simulations and basic experiments on laboratory setups [Kalender et al., Eur Radiol 22: 1–8, 2012]. Measurements of dose, technical image quality parameters, and surgical specimens on a pcBCT scanner have been completed. Comparative evaluation of surgical specimens showed that pcBCT outperformed mammography and digital breast tomosynthesis with respect to 3D spatial resolution, detectability of calcifications, and soft tissue delineation. Major barriers to widespread clinical use of BCT relate to radiation dose, imaging of microcalcifications, and adequate coverage of breast tissue near the chest wall. Adequate chest wall coverage is also technically challenging but recent progress in x-ray tube, detector and table design now enables full breast coverage in the majority of patients. At this time, BCT has been deemed to be suitable for diagnostic imaging but not yet for screening. The mean glandular dose (MGD) from BCT has been reported to be between 5.7 to 27.8 mGy, and this range is comparable to, and within the range of, the MGD of 2.6 to 31.6 mGy in diagnostic mammography

  3. Small-mammal density estimation: A field comparison of grid-based vs. web-based density estimators

    Science.gov (United States)

    Parmenter, R.R.; Yates, Terry L.; Anderson, D.R.; Burnham, K.P.; Dunnum, J.L.; Franklin, A.B.; Friggens, M.T.; Lubow, B.C.; Miller, M.; Olson, G.S.; Parmenter, Cheryl A.; Pollard, J.; Rexstad, E.; Shenk, T.M.; Stanley, T.R.; White, Gary C.

    2003-01-01

    blind” test allowed us to evaluate the influence of expertise and experience in calculating density estimates in comparison to simply using default values in programs CAPTURE and DISTANCE. While the rodent sample sizes were considerably smaller than the recommended minimum for good model results, we found that several models performed well empirically, including the web-based uniform and half-normal models in program DISTANCE, and the grid-based models Mb and Mbh in program CAPTURE (with AÌ‚ adjusted by species-specific full mean maximum distance moved (MMDM) values). These models produced accurate DÌ‚ values (with 95% confidence intervals that included the true D values) and exhibited acceptable bias but poor precision. However, in linear regression analyses comparing each model's DÌ‚ values to the true D values over the range of observed test densities, only the web-based uniform model exhibited a regression slope near 1.0; all other models showed substantial slope deviations, indicating biased estimates at higher or lower density values. In addition, the grid-based DÌ‚ analyses using full MMDM values for WÌ‚ area adjustments required a number of theoretical assumptions of uncertain validity, and we therefore viewed their empirical successes with caution. Finally, density estimates from the independent analysts were highly variable, but estimates from web-based approaches had smaller mean square errors and better achieved confidence-interval coverage of D than did grid-based approaches. Our results support the contention that web-based approaches for density estimation of small-mammal populations are both theoretically and empirically superior to grid-based approaches, even when sample size is far less than often recommended. In view of the increasing need for standardized environmental measures for comparisons among ecosystems and through time, analytical models based on distance sampling appear to offer accurate density estimation approaches for research

  4. The Literature Review on the Bilingualism in China from a Sociolinguistic View

    Institute of Scientific and Technical Information of China (English)

    康硕

    2015-01-01

    Against the background of globalization, sociolinguists have long been dedicated in the study of bilingualism.The Chinese-English bilingualism is demonstrated through a literature review,and analyzed from a sociolinguistic view in this paper.It explores a number of published articles,analyzes the bilingual education abd the phenomenon of Chinese-English bilingualism in China on the basis of literature review.

  5. Diviner lunar radiometer gridded brightness temperatures from geodesic binning of modeled fields of view

    Science.gov (United States)

    Sefton-Nash, E.; Williams, J.-P.; Greenhagen, B. T.; Aye, K.-M.; Paige, D. A.

    2017-12-01

    An approach is presented to efficiently produce high quality gridded data records from the large, global point-based dataset returned by the Diviner Lunar Radiometer Experiment aboard NASA's Lunar Reconnaissance Orbiter. The need to minimize data volume and processing time in production of science-ready map products is increasingly important with the growth in data volume of planetary datasets. Diviner makes on average >1400 observations per second of radiance that is reflected and emitted from the lunar surface, using 189 detectors divided into 9 spectral channels. Data management and processing bottlenecks are amplified by modeling every observation as a probability distribution function over the field of view, which can increase the required processing time by 2-3 orders of magnitude. Geometric corrections, such as projection of data points onto a digital elevation model, are numerically intensive and therefore it is desirable to perform them only once. Our approach reduces bottlenecks through parallel binning and efficient storage of a pre-processed database of observations. Database construction is via subdivision of a geodesic icosahedral grid, with a spatial resolution that can be tailored to suit the field of view of the observing instrument. Global geodesic grids with high spatial resolution are normally impractically memory intensive. We therefore demonstrate a minimum storage and highly parallel method to bin very large numbers of data points onto such a grid. A database of the pre-processed and binned points is then used for production of mapped data products that is significantly faster than if unprocessed points were used. We explore quality controls in the production of gridded data records by conditional interpolation, allowed only where data density is sufficient. The resultant effects on the spatial continuity and uncertainty in maps of lunar brightness temperatures is illustrated. We identify four binning regimes based on trades between the

  6. Commercial grade item (CGI) dedication of generators for nuclear safety related applications

    International Nuclear Information System (INIS)

    Das, R.K.; Hajos, L.G.

    1993-01-01

    The number of nuclear safety related equipment suppliers and the availability of spare and replacement parts designed specifically for nuclear safety related application are shrinking rapidly. These have made it necessary for utilities to apply commercial grade spare and replacement parts in nuclear safety related applications after implementing proper acceptance and dedication process to verify that such items conform with the requirements of their use in nuclear safety related application. The general guidelines for the commercial grade item (CGI) acceptance and dedication are provided in US Nuclear Regulatory Commission (NRC) Generic Letters and Electric Power Research Institute (EPRI) Report NP-5652, Guideline for the Utilization of Commercial Grade Items in Nuclear Safety Related Applications. This paper presents an application of these generic guidelines for procurement, acceptance, and dedication of a commercial grade generator for use as a standby generator at Salem Generating Station Units 1 and 2. The paper identifies the critical characteristics of the generator which once verified, will provide reasonable assurance that the generator will perform its intended safety function. The paper also delineates the method of verification of the critical characteristics through tests and provide acceptance criteria for the test results. The methodology presented in this paper may be used as specific guidelines for reliable and cost effective procurement and dedication of commercial grade generators for use as standby generators at nuclear power plants

  7. The accuracy of linear measurements of maxillary and mandibular edentulous sites in cone-beam computed tomography images with different fields of view and voxel sizes under simulated clinical conditions

    Energy Technology Data Exchange (ETDEWEB)

    Ganguly, Rumpa; Ramesh, Aruna; Pagni, Sarah [Tufts University School of Dental Medicine, Boston (United States)

    2016-06-15

    The objective of this study was to investigate the effect of varying resolutions of cone-beam computed tomography images on the accuracy of linear measurements of edentulous areas in human cadaver heads. Intact cadaver heads were used to simulate a clinical situation. Fiduciary markers were placed in the edentulous areas of 4 intact embalmed cadaver heads. The heads were scanned with two different CBCT units using a large field of view (13 cm×16 cm) and small field of view (5 cm×8 cm) at varying voxel sizes (0.3 mm, 0.2 mm, and 0.16 mm). The ground truth was established with digital caliper measurements. The imaging measurements were then compared with caliper measurements to determine accuracy. The Wilcoxon signed rank test revealed no statistically significant difference between the medians of the physical measurements obtained with calipers and the medians of the CBCT measurements. A comparison of accuracy among the different imaging protocols revealed no significant differences as determined by the Friedman test. The intraclass correlation coefficient was 0.961, indicating excellent reproducibility. Inter-observer variability was determined graphically with a Bland-Altman plot and by calculating the intraclass correlation coefficient. The Bland-Altman plot indicated very good reproducibility for smaller measurements but larger discrepancies with larger measurements. The CBCT-based linear measurements in the edentulous sites using different voxel sizes and FOVs are accurate compared with the direct caliper measurements of these sites. Higher resolution CBCT images with smaller voxel size did not result in greater accuracy of the linear measurements.

  8. comparative measurement o river for small hydro tive measurement

    African Journals Online (AJOL)

    eobe

    Keywords: Keywords: small hydropower, electric power, volum ... gathering systems. .... or revolving cups connected to the end. ..... Also, the float velocity may have been affected by wind ... completely dedicated as off-grid supply can meet the.

  9. Seasonal dependence of high-latitude electric fields

    International Nuclear Information System (INIS)

    de la Beaujardiere, O.; Leger, C.; Alcayde, D.; Fontanari, J.

    1991-01-01

    The seasonal dependence of the high-latitude electric field was investigated using Sondrestrom incoherent scatter radar data. Average ExB drifts were derived from 5 years of measurements centered around solar minimum. The electrostatic potentials that best fit the observed average electric field were calculated. It was found that the large-scale convection pattern significantly changes with season. This change involves the overall shape of the convection pattern, as well as the electric field intensity, and thus the total dawn-dusk potential across the polar cap. The cross polar cap potential drop is largest in fall, followed by winter, spring and summer. The small difference found between the summer and winter cross polar cap potential can be attributed to differing field-aligned potential drops. In view of the well-known relationship between field-aligned currents and parallel potential drop, this is consistent with the observations that Birkeland currents are larger in the summer than in winter. Changes in the overall shape of the convection pattern are consistent with the simple notion that the whole pattern is shifted toward the nightside as well as, to a lesser extent, toward the dawnside in summer as compared to winter. This assumption is based on the following observed effects: (1) The rotation of the overall convection pattern toward earlier local times with respect to the noon-midnight direction is maximum for summer on the dayside. (2) On the nightside, the Harang discontinuity is typically located within the radar field of view (Λ=67 to 82) in the winter averaged patterns, but it is equatorward of the field of view in summer. (3) The line that joins the dawn and dusk potential maxima is shifted toward the midnight sector in summer as compared to winter by about 5 degree. (4) In the dawn cell, the latitude of the convection reversal is the lowest during summer; in the dusk cell the latitude of the reversal is the lowest during winter

  10. Dedicated Linac for Radioneurosurgery at the National Institute of Neurology and Neurosurgery of Mexico

    Science.gov (United States)

    Celis-López, Miguel A.; Lárraga-Gutiérrez, José M.

    2003-09-01

    The objective is to present a description and the main clinical applications of this dedicated Linac for benign and malignant tumors in the central nervous system. The Novalis (BrainLab, Germany) is a 6 MV dedicated linac for a single high dose Radiosurgery (RS) and for fractionated doses in Stereotactic Radiotherapy with a high level of precision at the isocenter.

  11. Dedicated Linac for Radioneurosurgery at the National Institute of Neurology and Neurosurgery of Mexico

    International Nuclear Information System (INIS)

    Celis-Lopez, Miguel A.; Larraga-Gutierrez, Jose M.

    2003-01-01

    The objective is to present a description and the main clinical applications of this dedicated Linac for benign and malignant tumors in the central nervous system. The Novalis (BrainLab, Germany) is a 6 MV dedicated linac for a single high dose Radiosurgery (RS) and for fractionated doses in Stereotactic Radiotherapy with a high level of precision at the isocenter

  12. A development of an accelerator board dedicated for multi-precision arithmetic operations and its application to Feynman loop integrals

    International Nuclear Information System (INIS)

    Motoki, S; Ishikawa, T; Yuasa, F; Daisaka, H; Nakasato, N; Fukushige, T; Kawai, A; Makino, J

    2015-01-01

    Higher order corrections in perturbative quantum field theory are required for precise theoretical analysis to investigate new physics beyond the Standard Model. This indicates that we need to evaluate Feynman loop diagrams with multi-loop integrals which may require multi-precision calculation. We developed a dedicated accelerator system for multiprecision calculations (GRAPE9-MPX). We present performance results of our system for the case of Feynman two-loop box and three-loop selfenergy diagrams with multi-precision. (paper)

  13. Evaluation of a liquid ionization chamber for relative dosimetry in small and large fields of radiotherapy photon beams

    International Nuclear Information System (INIS)

    Benítez, E.M.; Casado, F.J.; García-Pareja, S.; Martín-Viera, J.A.; Moreno, C.; Parra, V.

    2013-01-01

    Commissioning and quality assurance of radiotherapy linear accelerators require measurement of the absorbed dose to water, and a wide range of detectors are available for absolute and relative dosimetry in megavoltage beams. In this paper, the PTW microLion isooctane-filled ionization chamber has been tested to perform relative measurements in a 6 MV photon beam from a linear accelerator. Output factors, percent depth dose and dose profiles have been obtained for small and large fields. These quantities have been compared with those from usual detectors in the routine practice. In order to carry out a more realistic comparison, an uncertainty analysis has been developed, taking type A and B uncertainties into account. The results present microLion as a good option when high spatial resolution is needed, thanks to its reduced sensitive volume. The liquid filling also provides a high signal compared to other detectors, like that based on air filling. Furthermore, the relative response of microLion when field size is varied suggests that this detector has energy dependence, since it is appreciated an over-response for small fields and an under-response for the large ones. This effect is more obvious for field sizes wider than 20 × 20 cm 2 , where the differences in percent depth dose at great depths exceed the uncertainties estimated in this study. - Highlights: • When high spatial resolution is required the results confirm the suitability of the liquid chamber. • Some energy dependence of the liquid detector can be appreciated in OFs and PDDs for small and large fields. • For field sizes >20 × 20 cm 2 , the differences in PDDs at great depths exceed the uncertainties estimated. • Some drawbacks should be considered: the time to reach stability, the high voltage supply required and the acquiring cost

  14. The dynamic behavior of magnetic fluid adsorbed to small permanent magnet in alternating magnetic field

    Energy Technology Data Exchange (ETDEWEB)

    Sudo, Seiichi, E-mail: sudo@akita-pu.ac.j [Faculty of Systems Science and Technology, Akita Prefectural University, Ebinokuchi 84-4, Yurihonjo 015-0055 (Japan); Asano, Daisaku [Faculty of Systems Science and Technology, Akita Prefectural University, Ebinokuchi 84-4, Yurihonjo 015-0055 (Japan); Takana, Hidemasa; Nishiyama, Hideya [Institute of Fluid Science, Tohoku University, Katahira 2-1-1, Aobaku, Sendai 980-8577 (Japan)

    2011-05-15

    The dynamic behavior of a magnetic fluid adsorbed to a small NdFeB permanent magnet subjected to an alternating magnetic field was studied with a high speed video camera system. The directions of alternating magnetic field are parallel and opposite to that of the permanent magnet. It was found that the surface of magnetic fluid responds to the external alternating magnetic field in elongation and contraction with a lot of spikes. Generation of a capillary magnetic fluid jet was observed in the neighbourhood of a specific frequency of alternating field. The effect of gravitational force on surface phenomena of magnetic fluid adsorbed to the permanent magnet was revealed. - Research Highlights: Magnetic fluid of the system responds to alternating magnetic field with higher frequencies. Large-amplitude surface motions of magnetic fluid occur at the specific frequencies of the external field. Capillary jets of magnetic fluid are generated at the natural frequency of the system.

  15. SU-F-T-408: On the Determination of Equivalent Squares for Rectangular Small MV Photon Fields

    International Nuclear Information System (INIS)

    Sauer, OA; Wegener, S; Exner, F

    2016-01-01

    Purpose: It is common practice to tabulate dosimetric data like output factors, scatter factors and detector signal correction factors for a set of square fields. In order to get the data for an arbitrary field, it is mapped to an equivalent square, having the same scatter as the field of interest. For rectangular fields both, tabulated data and empiric formula exist. We tested the applicability of such rules for very small fields. Methods: Using the Monte-Carlo method (EGSnrc-doseRZ), the dose to a point in 10cm depth in water was calculated for cylindrical impinging fluence distributions. Radii were from 0.5mm to 11.5mm with 1mm thickness of the rings. Different photon energies were investigated. With these data a matrix was constructed assigning the amount of dose to the field center to each matrix element. By summing up the elements belonging to a certain field, the dose for an arbitrary point in 10cm depth could be determined. This was done for rectangles up to 21mm side length. Comparing the dose to square field results, equivalent squares could be assigned. The results were compared to using the geometrical mean and the 4Xperimeter/area rule. Results: For side length differences less than 2mm, the difference between all methods was in general less than 0.2mm. For more elongated fields, relevant differences of more than 1mm and up to 3mm for the fields investigated occurred. The mean square side length calculated from both empiric formulas fitted much better, deviating hardly more than 1mm and for the very elongated fields only. Conclusion: For small rectangular photon fields, deviating only moderately from square both investigated empiric methods are sufficiently accurate. As the deviations often differ regarding their sign, using the mean improves the accuracy and the useable elongation range. For ratios larger than 2, Monte-Carlo generated data are recommended. SW is funded by Deutsche Forschungsgemeinschaft (SA481/10-1)

  16. SU-F-T-408: On the Determination of Equivalent Squares for Rectangular Small MV Photon Fields

    Energy Technology Data Exchange (ETDEWEB)

    Sauer, OA; Wegener, S; Exner, F [University of Wuerzburg, Wuerzburg (Germany)

    2016-06-15

    Purpose: It is common practice to tabulate dosimetric data like output factors, scatter factors and detector signal correction factors for a set of square fields. In order to get the data for an arbitrary field, it is mapped to an equivalent square, having the same scatter as the field of interest. For rectangular fields both, tabulated data and empiric formula exist. We tested the applicability of such rules for very small fields. Methods: Using the Monte-Carlo method (EGSnrc-doseRZ), the dose to a point in 10cm depth in water was calculated for cylindrical impinging fluence distributions. Radii were from 0.5mm to 11.5mm with 1mm thickness of the rings. Different photon energies were investigated. With these data a matrix was constructed assigning the amount of dose to the field center to each matrix element. By summing up the elements belonging to a certain field, the dose for an arbitrary point in 10cm depth could be determined. This was done for rectangles up to 21mm side length. Comparing the dose to square field results, equivalent squares could be assigned. The results were compared to using the geometrical mean and the 4Xperimeter/area rule. Results: For side length differences less than 2mm, the difference between all methods was in general less than 0.2mm. For more elongated fields, relevant differences of more than 1mm and up to 3mm for the fields investigated occurred. The mean square side length calculated from both empiric formulas fitted much better, deviating hardly more than 1mm and for the very elongated fields only. Conclusion: For small rectangular photon fields, deviating only moderately from square both investigated empiric methods are sufficiently accurate. As the deviations often differ regarding their sign, using the mean improves the accuracy and the useable elongation range. For ratios larger than 2, Monte-Carlo generated data are recommended. SW is funded by Deutsche Forschungsgemeinschaft (SA481/10-1)

  17. Reconstruction of tomographic images from projections of a small number of views by means of mathematical programming

    International Nuclear Information System (INIS)

    Kobayashi, Fujio; Yamaguchi, Shoichiro

    1985-01-01

    Fundamental studies have been made on the application of mathematical programming to the reconstruction of tomographic images from projections of a small number of views without requiring any circular symmetry nor periodicity. Linear programming and quadratic programming were applied to minimize the quadratic sum of the residue and to finally obtain optimized reconstruction images. The mathematical algorithms were verified by the method of computer simulation, and the relationship between the number of picture elements and the number of iterations necessary for convergence was also investigated. The methods of linear programming and quadratic programming require fairly simple mathematical procedures, and strict solutions can be obtained within a finite number of iterations. Their only draw back is the requirement of a large quantity of computer memory. But this problem will be desolved by the advent of large fast memory devices in the near future. (Aoki, K.)

  18. SLAPex Freeze/Thaw 2015: The First Dedicated Soil Freeze/Thaw Airborne Campaign

    Science.gov (United States)

    Kim, Edward; Wu, Albert; DeMarco, Eugenia; Powers, Jarrett; Berg, Aaron; Rowlandson, Tracy; Freeman, Jacqueline; Gottfried, Kurt; Toose, Peter; Roy, Alexandre; hide

    2016-01-01

    Soil freezing and thawing is an important process in the terrestrial water, energy, and carbon cycles, marking the change between two very different hydraulic, thermal, and biological regimes. NASA's Soil Moisture Active/Passive (SMAP) mission includes a binary freeze/thaw data product. While there have been ground-based remote sensing field measurements observing soil freeze/thaw at the point scale, and airborne campaigns that observed some frozen soil areas (e.g., BOREAS), the recently-completed SLAPex Freeze/Thaw (F/T) campaign is the first airborne campaign dedicated solely to observing frozen/thawed soil with both passive and active microwave sensors and dedicated ground truth, in order to enable detailed process-level exploration of the remote sensing signatures and in situ soil conditions. SLAPex F/T utilized the Scanning L-band Active/Passive (SLAP) instrument, an airborne simulator of SMAP developed at NASA's Goddard Space Flight Center, and was conducted near Winnipeg, Manitoba, Canada, in October/November, 2015. Future soil moisture missions are also expected to include soil freeze/thaw products, and the loss of the radar on SMAP means that airborne radar-radiometer observations like those that SLAP provides are unique assets for freeze/thaw algorithm development. This paper will present an overview of SLAPex F/T, including descriptions of the site, airborne and ground-based remote sensing, ground truth, as well as preliminary results.

  19. Multi-view L2-SVM and its multi-view core vector machine.

    Science.gov (United States)

    Huang, Chengquan; Chung, Fu-lai; Wang, Shitong

    2016-03-01

    In this paper, a novel L2-SVM based classifier Multi-view L2-SVM is proposed to address multi-view classification tasks. The proposed Multi-view L2-SVM classifier does not have any bias in its objective function and hence has the flexibility like μ-SVC in the sense that the number of the yielded support vectors can be controlled by a pre-specified parameter. The proposed Multi-view L2-SVM classifier can make full use of the coherence and the difference of different views through imposing the consensus among multiple views to improve the overall classification performance. Besides, based on the generalized core vector machine GCVM, the proposed Multi-view L2-SVM classifier is extended into its GCVM version MvCVM which can realize its fast training on large scale multi-view datasets, with its asymptotic linear time complexity with the sample size and its space complexity independent of the sample size. Our experimental results demonstrated the effectiveness of the proposed Multi-view L2-SVM classifier for small scale multi-view datasets and the proposed MvCVM classifier for large scale multi-view datasets. Copyright © 2015 Elsevier Ltd. All rights reserved.

  20. Chromophoric Dissolved Organic Matter and Dissolved Organic Carbon from Sea-Viewing Wide Field-of-View Sensor (SeaWiFS), Moderate Resolution Imaging Spectroradiometer (MODIS) and MERIS Sensors: Case Study for the Northern Gulf of Mexico

    OpenAIRE

    Blake A. Schaeffer; Thomas S. Bianchi; Eurico J. D'Sa; Christopher L. Osburn; Nazanin Chaichi Tehrani

    2013-01-01

    Empirical band ratio algorithms for the estimation of colored dissolved organic matter (CDOM) and dissolved organic carbon (DOC) for Sea-viewing Wide Field-of-view Sensor (SeaWiFS), Moderate Resolution Imaging Spectroradiometer (MODIS) and MERIS ocean color sensors were assessed and developed for the northern Gulf of Mexico. Match-ups between in situ measurements of CDOM absorption coefficients at 412 nm (aCDOM(412)) with that derived from SeaWiFS were examined using two previously reported r...

  1. Prospects of dedicated biodiesel engine vehicles in Malaysia and Indonesia

    International Nuclear Information System (INIS)

    Jayed, M.H.; Masjuki, H.H.; Kalam, M.A.; Mahlia, T.M.I.; Liaquat, A.M.; Husnawan, M.

    2011-01-01

    Petro diplomacy has played its role in last few decades and that makes energy security a major concern worldwide. Rapid climate change and environmental protection is another vital issue to be addressed in recent energy policies. So an alternative carbon neutral transport fuel is a must in new sustainable energy mix. Biodiesel has immense potentiality to be a part of a sustainable energy mix. In this energy scenario, Brazil's success is a role model in utilizing its agro-industry for reducing poverty, greenhouse gas emission and petro-dependency simultaneously. Brazil commercialized bioethanol in mass scale by introducing flexible fuel vehicles in market. This dedicated engine idea moralizes a new concept of dedicated biodiesel engine vehicles for Malaysia and Indonesia. Southeast Asian countries, i.e. Malaysia and Indonesia is the largest producer as well as exporter of palm oil. Growing at highest yield rate among other biodiesel feedstock, palm based biodiesel is a top exported product for this region. This paper will quantify the prospects of a dedicated biodiesel engine vehicle for Malaysia and Indonesia that will initiate palm based biodiesel in fuel supply chain by leapfrogging the barriers of biodiesel utilization by boosting local automobile industry simultaneously. This article will also review on energy scenario of Malaysia and Indonesia and their renewable energy policies and challenges for coming decades. (author)

  2. Fixed-focus camera objective for small remote sensing satellites

    Science.gov (United States)

    Topaz, Jeremy M.; Braun, Ofer; Freiman, Dov

    1993-09-01

    An athermalized objective has been designed for a compact, lightweight push-broom camera which is under development at El-Op Ltd. for use in small remote-sensing satellites. The high performance objective has a fixed focus setting, but maintains focus passively over the full range of temperatures encountered in small satellites. The lens is an F/5.0, 320 mm focal length Tessar type, operating over the range 0.5 - 0.9 micrometers . It has a 16 degree(s) field of view and accommodates various state-of-the-art silicon detector arrays. The design and performance of the objective is described in this paper.

  3. Thermal and ghost reflection modeling for a 180-deg. field-of-view long-wave infrared lens

    Science.gov (United States)

    Shi, Weimin; Couture, Michael E.

    2001-03-01

    Optics 1, Inc. has successfully designed and developed a 180 degree(s) field of view long wave infrared lens for USAF/AFRL under SBIR phase I and II funded projects in support of the multi-national Programmable Integrated Ordinance Suite (PIOS) program. In this paper, a procedure is presented on how to evaluate image degradation caused by asymmetric aerodynamic dome heating. In addition, a thermal gradient model is proposed to evaluate degradation caused by axial temperature gradient throughout the entire PIOS lens. Finally, a ghost reflection analysis is demonstrated with non-sequential model.

  4. Ex Vivo Perfusion-Simulation Measurements of Microbubbles as a Scattering Contrast Agent for Grating-Based X-Ray Dark-Field Imaging.

    Directory of Open Access Journals (Sweden)

    Astrid Velroyen

    Full Text Available The investigation of dedicated contrast agents for x-ray dark-field imaging, which exploits small-angle scattering at microstructures for contrast generation, is of strong interest in analogy to the common clinical use of high-atomic number contrast media in conventional attenuation-based imaging, since dark-field imaging has proven to provide complementary information. Therefore, agents consisting of gas bubbles, as used in ultrasound imaging for example, are of particular interest. In this work, we investigate an experimental contrast agent based on microbubbles consisting of a polyvinyl-alcohol shell with an iron oxide coating, which was originally developed for multimodal imaging and drug delivery. Its performance as a possible contrast medium for small-animal angiography was examined using a mouse carcass to realistically consider attenuating and scattering background signal. Subtraction images of dark field, phase contrast and attenuation were acquired for a concentration series of 100%, 10% and 1.3% to mimic different stages of dilution in the contrast agent in the blood vessel system. The images were compared to the gold-standard iodine-based contrast agent Solutrast, showing a good contrast improvement by microbubbles in dark-field imaging. This study proves the feasibility of microbubble-based dark-field contrast-enhancement in presence of scattering and attenuating mouse body structures like bone and fur. Therefore, it suggests a strong potential of the use of polymer-based microbubbles for small-animal dark-field angiography.

  5. Development of in-vivo micro CT system for small animals

    Energy Technology Data Exchange (ETDEWEB)

    Nam, Ki Yong; Lim, Jong Hyeok; Jeong, Young Jo; Park, Jeong Gwon [Institute for Radiological Imaging Science, Iksan (Korea, Republic of); Park, Jung Bung [DRGEM Corp., Seoul (Korea, Republic of); Yoon, Kwon Ha [Institute for Radiological Imaging Science and Medical School of Radiology, Iksan (Korea, Republic of)

    2005-07-01

    Computed tomography system with the spatial resolution of {approx}25 {mu}m has been developed for the application to small animals. This system is designed by gantry-rotation type for minimizing animal movement. To get image with micro-spatial resolution, system characteristic such as geometry between main components of source, specimen and detector, field of view, etc., is described in this paper. The requirements of x-ray spot size and CCD pixel size to approach the resolution are discussed. In-vivo imaging test for mouse is also presented as a result.

  6. Development of in-vivo micro CT system for small animals

    International Nuclear Information System (INIS)

    Nam, Ki Yong; Lim, Jong Hyeok; Jeong, Young Jo; Park, Jeong Gwon; Park, Jung Bung; Yoon, Kwon Ha

    2005-01-01

    Computed tomography system with the spatial resolution of ∼25 μm has been developed for the application to small animals. This system is designed by gantry-rotation type for minimizing animal movement. To get image with micro-spatial resolution, system characteristic such as geometry between main components of source, specimen and detector, field of view, etc., is described in this paper. The requirements of x-ray spot size and CCD pixel size to approach the resolution are discussed. In-vivo imaging test for mouse is also presented as a result

  7. The impact of instrument field of view on measurements of cloudy-sky spectral radiances from space: application to IRIS and IMG

    Energy Technology Data Exchange (ETDEWEB)

    Brindley, H.E. E-mail: h.brindley@ic.ac.uk; Harries, J.E

    2003-05-15

    Spatially resolved images from the MODerate Resolution Imaging Spectrometer (MODIS) instrument are used to investigate the impact of a change in spatial field of view, from that typical of the Nimbus 4 Infrared Interferometer Spectrometer (IRIS) to that of the Interferometric Monitor for Greenhouse Gases (IMG), upon the spectral outgoing longwave radiation (OLR). Considering all-sky conditions it is found that for a typical tropical scene, approximately 150 paired measurements are required to obtain agreement to within {+-}2 K in the average brightness temperature (T{sub B}), in the most transparent window channels. At mid-latitudes, the reduced scene variability means that fewer observations are required to meet the same criterion. For clear- and cloudy-sky separation a simple threshold technique based on the window T{sub B} and underlying sea-surface temperature tends to result in a systematic underestimate of the average cloudy T{sub B} by the larger field of view. A better estimate can be obtained by applying a double threshold to discriminate against the most mixed scenes.

  8. Activities in the field of small nuclear power reactors

    Energy Technology Data Exchange (ETDEWEB)

    Baranaev, Yu.D.; Dolgov, V.V.; Sergeev, Yu.A. [Physics and Power Eng. Inst., Obninsk (Russian Federation). State Res. Centre

    1997-10-01

    Considerable efforts have been undertaken for development, design, construction and operation of small nuclear power plants (SNPP) in Russia. Systematic work in this area was started in the mid-1950s. The driving force for this activity was the awareness that the use of nuclear fuel would practically solve the problem of fuel transportation. As far as the remote northern regions are concerned, this provides the key advantage of nuclear over conventional energy sources. The activity in the field of SNPP has included pre-design analytical feasibility studies and experimental research including large-scale experiments on critical assemblies, thermal and hydraulic test facilities, research and development work, construction and operation of pilot and demonstration SNPPs, and finally, construction and more than 20 years of operation of the commercial SNPP, namely Bilibino nuclear co-generation plant (NCGP) located in Chukotka autonomous district, which is one of the most remote regions in the far north-east of Russia. In recent years, studies have been carried out on the development of several new SNPP designs using advanced reactors of the new generation. Among these are the second stage of Bilibino NCGP, floating NCGP VOLNOLOM-3, designated for siting in the Arctic sea coast area, and a nuclear district heating plant for the town of Apatity, in the Murmansk region. In this paper, the background and current status of the SNPPs are given, and the problems as well as prospects of small nuclear reactors development and implementation are considered. (orig.) 20 refs.

  9. Observation-status patients in children's hospitals with and without dedicated observation units in 2011.

    Science.gov (United States)

    Macy, Michelle L; Hall, Matthew; Alpern, Elizabeth R; Fieldston, Evan S; Shanley, Leticia A; Hronek, Carla; Hain, Paul D; Shah, Samir S

    2015-06-01

    Pediatric observation units (OUs) have demonstrated reductions in lengths of stay (LOS) and costs of care. Hospital-level outcomes across all observation-status stays have not been evaluated in relation to the presence of a dedicated OU in the hospital. To compare observation-status stay outcomes in hospitals with and without a dedicated OU. Cross-sectional analysis of hospital administrative data. Observation-status stay outcomes were compared in hospitals with and without a dedicated OU across 4 categories: (1) LOS, (2) standardized costs, (3) conversion to inpatient status, and (4) return care. Observation-status stays in 31 free-standing children's hospitals contributing observation patient data to the Pediatric Health Information System database, 2011. Fifty-one percent of the 136,239 observation-status stays in 2011 occurred in 14 hospitals with a dedicated OU; the remainder were in 17 hospitals without. The percentage of observation-status same-day discharges was higher in hospitals with a dedicated OU compared with hospitals without (23.8 vs 22.1, P hospitals with a dedicated OU (11.06%) compared with hospitals without (9.63%, P hospital-level outcomes. Inclusion of location of care (eg, dedicated OU, inpatient unit, emergency department) in hospital administrative datasets would allow for more meaningful comparisons of models of hospital care. © 2015 Society of Hospital Medicine.

  10. Dose enhancement in radiotherapy of small lung tumors using inline magnetic fields: A Monte Carlo based planning study

    Energy Technology Data Exchange (ETDEWEB)

    Oborn, B. M., E-mail: brad.oborn@gmail.com [Illawarra Cancer Care Centre (ICCC), Wollongong, NSW 2500, Australia and Centre for Medical Radiation Physics (CMRP), University of Wollongong, Wollongong, NSW 2500 (Australia); Ge, Y. [Sydney Medical School, University of Sydney, NSW 2006 (Australia); Hardcastle, N. [Northern Sydney Cancer Centre, Royal North Shore Hospital, Sydney, NSW 2065 (Australia); Metcalfe, P. E. [Centre for Medical Radiation Physics (CMRP), University of Wollongong, Wollongong NSW 2500, Australia and Ingham Institute for Applied Medical Research, Liverpool, NSW 2170 (Australia); Keall, P. J. [Sydney Medical School, University of Sydney, NSW 2006, Australia and Ingham Institute for Applied Medical Research, Liverpool, NSW 2170 (Australia)

    2016-01-15

    Purpose: To report on significant dose enhancement effects caused by magnetic fields aligned parallel to 6 MV photon beam radiotherapy of small lung tumors. Findings are applicable to future inline MRI-guided radiotherapy systems. Methods: A total of eight clinical lung tumor cases were recalculated using Monte Carlo methods, and external magnetic fields of 0.5, 1.0, and 3 T were included to observe the impact on dose to the planning target volume (PTV) and gross tumor volume (GTV). Three plans were 6 MV 3D-CRT plans while 6 were 6 MV IMRT. The GTV’s ranged from 0.8 to 16 cm{sup 3}, while the PTV’s ranged from 1 to 59 cm{sup 3}. In addition, the dose changes in a 30 cm diameter cylindrical water phantom were investigated for small beams. The central 20 cm of this phantom contained either water or lung density insert. Results: For single beams, an inline magnetic field of 1 T has a small impact in lung dose distributions by reducing the lateral scatter of secondary electrons, resulting in a small dose increase along the beam. Superposition of multiple small beams leads to significant dose enhancements. Clinically, this process occurs in the lung tissue typically surrounding the GTV, resulting in increases to the D{sub 98%} (PTV). Two isolated tumors with very small PTVs (3 and 6 cm{sup 3}) showed increases in D{sub 98%} of 23% and 22%. Larger PTVs of 13, 26, and 59 cm{sup 3} had increases of 9%, 6%, and 4%, describing a natural fall-off in enhancement with increasing PTV size. However, three PTVs bounded to the lung wall showed no significant increase, due to lack of dose enhancement in the denser PTV volume. In general, at 0.5 T, the GTV mean dose enhancement is around 60% lower than that at 1 T, while at 3 T, it is 5%–60% higher than 1 T. Conclusions: Monte Carlo methods have described significant and predictable dose enhancement effects in small lung tumor plans for 6 MV radiotherapy when an external inline magnetic field is included. Results of this study

  11. Evaluating the use of dedicated swab for rapid antigen detection ...

    African Journals Online (AJOL)

    Evaluating the use of dedicated swab for rapid antigen detection testing in group a ... African Journal of Clinical and Experimental Microbiology ... Several generations of rapid antigen detection tests (RADTs) have been developed to facilitate ...

  12. Photon small-field measurements with a CMOS active pixel sensor.

    Science.gov (United States)

    Spang, F Jiménez; Rosenberg, I; Hedin, E; Royle, G

    2015-06-07

    In this work the dosimetric performance of CMOS active pixel sensors for the measurement of small photon beams is presented. The detector used consisted of an array of 520  × 520 pixels on a 25 µm pitch. Dosimetric parameters measured with this sensor were compared with data collected with an ionization chamber, a film detector and GEANT4 Monte Carlo simulations. The sensor performance for beam profiles measurements was evaluated for field sizes of 0.5  × 0.5 cm(2). The high spatial resolution achieved with this sensor allowed the accurate measurement of profiles, beam penumbrae and field size under lateral electronic disequilibrium. Field size and penumbrae agreed within 5.4% and 2.2% respectively with film measurements. Agreements with ionization chambers better than 1.0% were obtained when measuring tissue-phantom ratios. Output factor measurements were in good agreement with ionization chamber and Monte Carlo simulation. The data obtained from this imaging sensor can be easily analyzed to extract dosimetric information. The results presented in this work are promising for the development and implementation of CMOS active pixel sensors for dosimetry applications.

  13. New quantitative and multi-modal approach for in-vivo studies of small animals: coupling of the {beta}-microprobe with magnetic techniques and development of voxelized rat and mouse phantoms; Nouvelle approche multimodale et quantitative pour les etudes in vivo chez le petit animal: couplage de la {beta}-MicroProbe aux techniques magnetiques et developpement de fantomes de rat et de souris voxelises

    Energy Technology Data Exchange (ETDEWEB)

    Desbree, A

    2005-09-15

    For the last 15 years, animal models that mimic human disorders have become ubiquitous participants to understand biological mechanisms and human disorders and to evaluate new therapeutic approaches. The necessity to study these models in the course of time has stimulated the development of instruments dedicated to in vivo small animal studies. To further understand physiopathological processes, the current challenge is to couple simultaneously several of these methods. Given this context, the combination of the magnetic and radioactive techniques remains an exciting challenge since it is still limited by strict technical constraints. Therefore we propose to couple the magnetic techniques with the radiosensitive Beta-Microprobe, developed in the IPB group and which shown to be an elegant alternative to PET measurements. In this context, the thesis was dedicated to the study of the coupling feasibility from a physical point of view, by simulation and experimental characterizations. Then, the determination of a biological protocol was carried out on the basis of pharmacokinetic studies. The experiments have shown the possibility to use the probe for radioactive measurements under intense magnetic field simultaneously to anatomical images acquisitions. Simultaneously, we have sought to improve the quantification of the radioactive signal using a voxelized phantom of a rat brain. Finally, the emergence of transgenic models led us to reproduce pharmacokinetic studies for the mouse and to develop voxelized mouse phantoms. (author)

  14. Vertical field MR imaging of upper thorax and spine in small children

    International Nuclear Information System (INIS)

    Brockstedt, S.; Malmgren, N.; Malmgren, L.; Ivarsson, M.L.; Larsson, E.M.; Holtaas, S.; Staahlberg, F.

    1993-01-01

    To improve image quality in a vertical field MR imaging unit, operating at low field strength (0.3 T), we have designed a half-elliptical coil for use in the upper thoracic region of small children. Our intention was also to shorten the examination time, which until now has been long, because several scans with different coils have been necessary to cover the thoracic region. The experimental coil is designed so that a child's shoulders fit into the central region. The coil consists of 2 serially connected cable-loops, mounted on a foam rubber vest. The coil performance was tested in a phantom and improvements relative to standard coils were demonstrated in in vivo studies. The results indicate that by using the half-elliptical coil, the signal-to-noise (S/N) ratio can be improved by a factor of 2 to 3 in the thoracic region of a child. (orig.)

  15. SU-F-T-610: Comparison of Output Factors for Small Radiation Fields Used in SBRT Treatment

    International Nuclear Information System (INIS)

    Gupta, R; Eldib, A; Li, J; Ma, C

    2016-01-01

    Purpose: In order to fundamentally understand our previous dose verification results between measurements and calculations from treatment planning system (TPS) for SBRT plans for different sized targets, the goal of the present work was to compare output factors for small fields measured using EDR2 films with TPS and Monet Carlo (MC) simulations. Methods: 6MV beam was delivered to EDR2 films for each of the following field sizes; 1×1 cm"2, 1.5×1.5 cm"2, 2×2 cm"2, 3×3 cm"2, 4×4 cm"2, 5×5 cm"2 and 10×10 cm"2. The films were developed in a film processer, then scanned with a Vidar VXR-16 scanner and analyzed using RIT113 version 6.1. A standard calibration curve was obtained with the 6MV beam and was used to get absolute dose for measured field sizes. Similar plans for all fields sizes mentioned above were generated using Eclipse with the Analytical Anisotropic Algorithm. Similarly, MC simulations were carried out using the MCSIM, an in-house MC code for different field sizes. Output factors normalized to 10×10 cm"2 reference field were calculated for different field sizes in all the three cases and compared. Results: For field sizes ranging from 1×1 cm"2 to 2×2 cm"2, the differences in output factors between measurements (films), TPS and MC simulations were within 0.22%. For field sizes ranging from 3×3cm"2 to 5×5cm"2, differences in output factors were within 0.10%. Conclusion: No clinically significant difference was obtained in output factors for different field sizes acquired from films, TPS and MC simulations. Our results showed that the output factors are predicted accurately from TPS when compared to the actual measurements and superior dose calculation Monte Carlo method. This study would help us in understanding our previously obtained dose verification results for small fields used in the SBRT treatment.

  16. Probing the nature of AX J0043-737: Not an 87 ms pulsar in the Small Magellanic Cloud

    Science.gov (United States)

    Maitra, C.; Ballet, J.; Esposito, P.; Haberl, F.; Tiengo, A.; Filipović, M. D.; Acero, F.

    2018-05-01

    Aims: AX J0043-737 is a source in the ASCA catalogue whose nature is uncertain. It is most commonly classified as a Crab-like pulsar in the Small Magellanic Cloud (SMC) following apparent detection of pulsations at 87 ms from a single ASCA observation. A follow-up ASCA observation was not able to confirm this, and the X-ray detection of the source has not been reported since. Methods: We studied the nature of the source with a dedicated XMM-Newton observation. We ascertained the source position, searched for the most probable counterpart, and studied the X-ray spectrum. We also analysed other archival observations with the source in the field of view to study its long-term variability. Results: With the good position localisation capability of XMM-Newton, we identify the counterpart of the source as MQS J004241.66-734041.3, an active galactic nucleus (AGN) behind the SMC at a redshift of 0.95. The X-ray spectrum can be fitted with an absorbed power law with a photon-index of Γ = 1.7, which is consistent with that expected from AGNs. By comparing the current XMM-Newton observation with an archival XMM-Newton and two other ASCA observations of the source, we find signatures of long-term variability, another common phenomenon in AGNs. All of the above are consistent with AX J0043-737 being an AGN behind the SMC.

  17. Galaxies in the Diffuse Baryon Field Approaching Reionization: A Joint Study with JWST, HST, and Large Telescopes

    Science.gov (United States)

    Simcoe, Robert

    2017-08-01

    Our team is conducting a dedicated survey for emission-line galaxies at 5 6 quasars, using JWST/NIRCAM's slitless grism in a 110 hour GTO allocation. We have acquired deep near-IR spectra of the QSOs, revealing multiple heavy-element absorption systems and probing the HI optical depth within each object's survey volume. These data will provide the first systematic view of the circumgalactic medium at z > 4, allowing us to study early metal enrichment, correlations of the intergalactic HI optical depth with galaxy density, and the environment of the quasar hosts. These fields generally do not have deep multicolor photometry that would facilitate selection of broadband dropout galaxies for future observation with JWST/NIRSPEC. However during long spectroscopic integrations with NIRCAM's long channel we will obtain deep JWST photometry in F115W and F200W, together with F356W for wavelength calibration. Here we request 30 orbits with HST/ACS to acquire deep optical photometry that (together with the JWST IR bands) will constrain SED models and enable dropout selection of fainter objects. For lower redshift objects the rest-UV ACS data will improve estimates of star formation rate and stellar mass. Within a Small-GO program scope we will obtain sensitivity similar to CANDELS-Deep in all six fields, and approximately double the size of our galaxy sample appropriate for JWST/NIRSPEC followup at redshifts approaching the reionization epoch.

  18. Engine with pulse-suppressed dedicated exhaust gas recirculation

    Science.gov (United States)

    Keating, Edward J.; Baker, Rodney E.

    2016-06-07

    An engine assembly includes an intake assembly, a spark-ignited internal combustion engine, and an exhaust assembly. The intake assembly includes a charge air cooler disposed between an exhaust gas recirculation (EGR) mixer and a backpressure valve. The charge air cooler has both an inlet and an outlet, and the back pressure valve is configured to maintain a minimum pressure difference between the inlet of the charge air cooler and an outlet of the backpressure valve. A dedicated exhaust gas recirculation system is provided in fluid communication with at least one cylinder and with the EGR mixer. The dedicated exhaust gas recirculation system is configured to route all of the exhaust gas from the at least one cylinder to the EGR mixer for recirculation back to the engine.

  19. TU-CD-304-07: Intensity Modulated Electron Beam Therapy Employing Small Fields in Virtual Scanning Mode

    International Nuclear Information System (INIS)

    Rodrigues, A; Yin, F; Wu, Q; Liang, B

    2015-01-01

    Purpose: Dynamic electron radiation therapies such as dynamic electron arc radiotherapy (DEAR) utilize small fields to provide target conformity and fluence modulation. The purpose of this study is to demonstrate the feasibility of virtual scanning mode using small fields. Methods: Monte Carlo simulations (EGSnrc/BEAMnrc/DOSXYZnrc) were performed using validated Varian TrueBeam phase space files for electron beam energies of 6, 9, 12, and 16 MeV and square/circular fields (1×1/1, 2×2/2, 3×3/3, 4×4/4, 5×5/5 cm"2/cm diameter). Resulting dose distributions (kernels) were used for subsequent calculations. The following analyses were performed: (1) Comparison of composite square fields and reference 10×10 cm"2 dose distributions and (2) Scanning beam deliveries for square and circular fields realized as the convolution of kernels and scanning pattern. Preliminary beam weight and pattern optimization were also performed. Two linear scans of 10 cm with/without overlap were modeled. Comparison metrics included depth and orthogonal profiles at dmax. Results: (1) Composite fields regained reference depth dose profiles for most energies and fields within 5%. Smaller kernels and higher energies increased dose in the build-up and Bremsstrahlung region (30%, 16MeV and 1×1 cm"2), while reference dmax was maintained for all energies and composite fields. Smaller kernels (<2×2 cm"2) maintained penumbra and field size within 0.2 cm, and flatness within 2%. Deterioration of penumbra for larger kernels (5×5 cm"2) were observed. Balancing desirable dosimetry and efficiencies suggests that smaller kernels are used at edges and larger kernels in the center of the target. (2) Beam weight optimization improved cross-plane penumbra (0.2 cm) and increased the field size (0.4 cm) on average. In-plane penumbra and field size remained unchanged. Overlap depended on kernel size and optimal overlap resulted in flatness ±2%. Conclusion: Dynamic electron beam therapy in virtual scanning

  20. A closer look at RapidArc (registered) radiosurgery plans using very small fields

    International Nuclear Information System (INIS)

    Fog, Lotte S; Rasmussen, Jens F B; Aznar, Marianne; Kjaer-Kristoffersen, Flemming; Vogelius, Ivan R; Engelholm, Svend Aage; Bangsgaard, Jens Peter

    2011-01-01

    RapidArc (registered) has become the treatment of choice for an increasing number of treatment sites in many clinics. The extensive use of multiple subfields in RapidArc (registered) treatments presents unique challenges, especially for small targets treated in few fractions. In this work, very small static fields and subsequently RapidArc (registered) and conventional plans for two targets (0.4 and 9.9 cm 3 ) were investigated. Doses from static fields 1-4 MLC leaves (0.25-1.00 cm) wide, and larger fields with 1-4 MLC leaves closed in their centres, were measured using the portal dosimeter-based QA system EPIQA (v 1.3) and gafchromic film. RapidArc and conventional plans for two tumours were then measured using EPIQA, gafchromic EBT2 film and the phantom-based QA system Delta4. Eclipse 8.6 and 8.9, grid spacings of 1.25 and 2.50 mm and a Varian HD linac were used. For static fields one MLC leaf wide, the dose was underestimated by Eclipse by as much as 53% (v 8.6, 2.5 mm grid). Eclipse underestimated the dose downstream from a few MLC leaves closed in the centre of a large MLC field by as much as 30%. Eclipse consistently overestimated the width of the penumbra by about 100%. For the conventional plans, there was good agreement between the calculated and measured dose for the 9.9 cm 3 PTV, but a 10% underdose was observed for the 0.4 cm 3 PTV. For the RapidArc (registered) plans, the measured dose for the 9.9 cm 3 PTV was in good agreement with the calculated one. However, for the 0.4 cm 3 PTV about 10% overdosing was detected (Eclipse v 8.6, 2.5 mm grid spacing). EPIQA data indicated that the measured dose profiles were overmodulated compared to the calculated one. The use of small subfields, typically a few MLC leaves wide, or larger fields with one or a few MLC leaves closed in its centre can result in significant errors in the dose calculation. The detector systems used vary in their ability to detect the discrepancies. Using a smaller grid size and newer

  1. Off disk-center potential field calculations using vector magnetograms

    Science.gov (United States)

    Venkatakrishnan, P.; Gary, G. Allen

    1989-01-01

    A potential field calculation for off disk-center vector magnetograms that uses all the three components of the measured field is investigated. There is neither any need for interpolation of grid points between the image plane and the heliographic plane nor for an extension or a truncation to a heliographic rectangle. Hence, the method provides the maximum information content from the photospheric field as well as the most consistent potential field independent of the viewing angle. The introduction of polarimetric noise produces a less tolerant extrapolation procedure than using the line-of-sight extrapolation, but the resultant standard deviation is still small enough for the practical utility of this method.

  2. SU-F-T-490: Separating Effects Influencing Detector Response in Small MV Photon Fields

    Energy Technology Data Exchange (ETDEWEB)

    Wegener, S; Sauer, O [University of Wuerzburg, Wuerzburg (Germany)

    2016-06-15

    Purpose: Different detector properties influence their responses especially in field sizes below the lateral electron range. Due to the finite active volume, the detector density and electron perturbation at other structural parts, the response factor is in general field size dependent. We aimed to visualize and separate the main effects contributing to detector behavior for a variety of detector types. This was achieved in an experimental setup, shielding the field center. Thus, effects caused by scattered radiation could be examined separately. Methods: Signal ratios for field sizes down to 8 mm (SSD 90 cm, water depth 10 cm) of a 6MV beam from a Siemens Primus LINAC were recorded with several detectors: PTW microDiamond and PinPoint ionization chamber, shielded diodes (PTW P-60008, IBA PFD and SNC Edge) and unshielded diodes (PTW E-60012 and IBA SFD). Measurements were carried out in open fields and with an aluminum pole of 4 mm diameter as a central block. The geometric volume effect was calculated from profiles obtained with Gafchromic EBT3 film, evaluated using FilmQA Pro software (Ashland, USA). Results: Volume corrections were 1.7% at maximum. After correction, in small open fields, unshielded diodes showed a lower response than the diamond, i.e. diamond detector over-response seems to be higher than that for unshielded diodes. Beneath the block, this behavior was amplified by a factor of 2. For the shielded diodes, the overresponse for small open fields could be confirmed. However their lateral response behavior was strongly type dependent, e.g. the signal ratio dropped from 1.02 to 0.98 for the P-60008 diode. Conclusion: The lateral detector response was experimentally examined. Detector volume and density alone do not fully account for the field size dependence of detector response. Detector construction details play a major role, especially for shielded diodes.

  3. 18F-FDG PET of the hands with a dedicated high-resolution PEM system (arthro-PET): correlation with PET/CT, radiography and clinical parameters.

    Science.gov (United States)

    Mhlanga, Joyce C; Carrino, John A; Lodge, Martin; Wang, Hao; Wahl, Richard L

    2014-12-01

    The aim of this study was to prospectively determine the feasibility and compare the novel use of a positron emission mammography (PEM) scanner with standard PET/CT for evaluating hand osteoarthritis (OA) with (18)F-FDG. Institutional review board approval and written informed consent were obtained for this HIPAA-compliant prospective study in which 14 adults referred for oncological (18)F-FDG PET/CT underwent dedicated hand PET/CT followed by arthro-PET using the PEM device. Hand radiographs were obtained and scored for the presence and severity of OA. Summed qualitative and quantitative joint glycolytic scores for each modality were compared with the findings on plain radiography and clinical features. Eight patients with clinical and/or radiographic evidence of OA comprised the OA group (mean age 73 ± 7.7 years). Six patients served as the control group (53.7 ± 9.3 years). Arthro-PET quantitative and qualitative joint glycolytic scores were highly correlated with PET/CT findings in the OA patients (r = 0.86. p = 0.007; r = 0.94, p = 0.001). Qualitative arthro-PET and PET/CT joint scores were significantly higher in the OA patients than in controls (38.7 ± 6.6 vs. 32.2 ± 0.4, p = 0.02; 37.5 ± 5.4 vs. 32.2 ± 0.4, p = 0.03, respectively). Quantitative arthro-PET and PET/CT maximum SUV-lean joint scores were higher in the OA patients, although they did not reach statistical significance (20.8 ± 4.2 vs. 18 ± 1.8, p = 0.13; 22.8 ± 5.38 vs. 20.1 ± 1.54, p = 0.21). By definition, OA patients had higher radiographic joint scores than controls (30.9 ± 31.3 vs. 0, p = 0.03). Hand imaging using a small field of view PEM system (arthro-PET) with FDG is feasible, performing comparably to PET/CT in assessing metabolic joint activity. Arthro-PET and PET/CT showed higher joint FDG uptake in OA. Further exploration of arthro-PET in arthritis management is warranted.

  4. Special relativity from observer's mathematics point of view

    Science.gov (United States)

    Khots, Boris; Khots, Dmitriy

    2015-09-01

    When we create mathematical models for quantum theory of light we assume that the mathematical apparatus used in modeling, at least the simplest mathematical apparatus, is infallible. In particular, this relates to the use of "infinitely small" and "infinitely large" quantities in arithmetic and the use of Newton - Cauchy definitions of a limit and derivative in analysis. We believe that is where the main problem lies in contemporary study of nature. We have introduced a new concept of Observer's Mathematics (see www.mathrelativity.com). Observer's Mathematics creates new arithmetic, algebra, geometry, topology, analysis and logic which do not contain the concept of continuum, but locally coincide with the standard fields. We use Einstein special relativity principles and get the analogue of classical Lorentz transformation. This work considers this transformation from Observer's Mathematics point of view.

  5. SU-E-T-423: TrueBeam Small Field Dosimetry Using Commercial Plastic Scintillation and Other Stereotactic Detectors

    Energy Technology Data Exchange (ETDEWEB)

    Pino, R [Houston Methodist Hospital, Houston, TX (United States); Therriault-Proulx, F; Wang, X; Yang, J; Beddar, S [University of Texas MD Anderson Cancer Center, Houston, TX (United States)

    2014-06-01

    Purpose: To perform dose profile and output factor (OF) measurements with the Exradin W1 plastic scintillation detector (PSD) for small fields made by the high-definition multi-leaf collimator (MLC) on the TrueBeam STx system and to compare them to values measured with an IBA CC01 ionization chamber and a Sun Nuclear Edge detector diode for 6 MV photon beams. Methods: The Exradin W1 is a new small volume near-water equivalent and energy independent PSD manufactured by Standard Imaging, Inc. All measurements were performed in an IBA Blue Phantom water tank. Square MLC-shaped fields with sides ranging from 0.5 cm to 2 cm and jawshaped fields with sides ranging from 1 cm to 40 cm were measured using an SAD setup at 10 cm depth. Dose profile and percent depth dose (PDD) measurements were also taken under the same conditions for MLC fields 0.5×0.5 and 1×1 cm2 in size with jaws at 2×2cm2. The CC01 and W1 were vertically mounted. Results: OFs measured with the W1 for jaw only square fields were consistent with the ones measured with a Farmers PTW TN33013 ion chamber (1.8% maximum deviation). OF and penumbra measurement results are presented below. PDDs measured for all detectors are within 1.5% for the 0.5×0.5 cm2 and within 1% for the 1×1 cm2 MLC fields.Output factors:MLC size W1 CC01 EDGE0.5cm 0.555 0.541 0.5851.0cm 0.716 0.702 0.7331.5cm 0.779 0.761 0.7772.0cm 0.804 0.785 0.796Penumbras (mm):MLC size W1 CC01 EDGE0.5cm 2.7 2.9 2.51.0cm 3.0 3.4 2. Conclusion: OFs measured for small MLC fields were consistent with the ones measured with the other stereotactic detectors. Measured penumbras are consistent with detector size. The Exradin W1 PSD is an excellent choice for characterizing MLC-shaped small beam dosimetry used for stereotactic radiosurgery and body radiation therapy. Sam Beddar would like to disclose a NIH/NCI SBIR Phase II grant (2R44CA153824-02A1) with Standard Imaging, Title: “Water-Equivalent Plastic Scintillation Detectors for Small Field

  6. SU-E-T-423: TrueBeam Small Field Dosimetry Using Commercial Plastic Scintillation and Other Stereotactic Detectors

    International Nuclear Information System (INIS)

    Pino, R; Therriault-Proulx, F; Wang, X; Yang, J; Beddar, S

    2014-01-01

    Purpose: To perform dose profile and output factor (OF) measurements with the Exradin W1 plastic scintillation detector (PSD) for small fields made by the high-definition multi-leaf collimator (MLC) on the TrueBeam STx system and to compare them to values measured with an IBA CC01 ionization chamber and a Sun Nuclear Edge detector diode for 6 MV photon beams. Methods: The Exradin W1 is a new small volume near-water equivalent and energy independent PSD manufactured by Standard Imaging, Inc. All measurements were performed in an IBA Blue Phantom water tank. Square MLC-shaped fields with sides ranging from 0.5 cm to 2 cm and jawshaped fields with sides ranging from 1 cm to 40 cm were measured using an SAD setup at 10 cm depth. Dose profile and percent depth dose (PDD) measurements were also taken under the same conditions for MLC fields 0.5×0.5 and 1×1 cm2 in size with jaws at 2×2cm2. The CC01 and W1 were vertically mounted. Results: OFs measured with the W1 for jaw only square fields were consistent with the ones measured with a Farmers PTW TN33013 ion chamber (1.8% maximum deviation). OF and penumbra measurement results are presented below. PDDs measured for all detectors are within 1.5% for the 0.5×0.5 cm2 and within 1% for the 1×1 cm2 MLC fields.Output factors:MLC size W1 CC01 EDGE0.5cm 0.555 0.541 0.5851.0cm 0.716 0.702 0.7331.5cm 0.779 0.761 0.7772.0cm 0.804 0.785 0.796Penumbras (mm):MLC size W1 CC01 EDGE0.5cm 2.7 2.9 2.51.0cm 3.0 3.4 2. Conclusion: OFs measured for small MLC fields were consistent with the ones measured with the other stereotactic detectors. Measured penumbras are consistent with detector size. The Exradin W1 PSD is an excellent choice for characterizing MLC-shaped small beam dosimetry used for stereotactic radiosurgery and body radiation therapy. Sam Beddar would like to disclose a NIH/NCI SBIR Phase II grant (2R44CA153824-02A1) with Standard Imaging, Title: “Water-Equivalent Plastic Scintillation Detectors for Small Field

  7. Gravity Field Constraints on the Upper Mantle of Northwestern Europe

    NARCIS (Netherlands)

    Root, B.C.

    2017-01-01

    In the last decade, the gravity field of the Earth has been observed with increased coverage due to dedicated satellite missions, which resulted in higher resolution and more accurate global gravity field models than were previously available. These models make it possible to study large scale

  8. Fusion of Data from Heterogeneous Sensors with Distributed Fields of View and Situation Evaluation for Advanced Driver Assistance Systems

    OpenAIRE

    Otto, Carola

    2013-01-01

    In order to develop a driver assistance system for pedestrian protection, pedestrians in the environment of a truck are detected by radars and a camera and are tracked across distributed fields of view using a Joint Integrated Probabilistic Data Association filter. A robust approach for prediction of the system vehicles trajectory is presented. It serves the computation of a probabilistic collision risk based on reachable sets where different sources of uncertainty are taken into account.

  9. Small clusters with anisotropic antiferromagnetic exchange in a magnetic field

    International Nuclear Information System (INIS)

    Parkinson, J B; Elliott, R J; Timonen, J

    2004-01-01

    We consider small symmetric clusters of magnetic atoms (spins) with anisotropic exchange interaction between the atoms in a magnetic field at zero temperature. The inclusion of the anisotropy leads to a wealth of different phases as a function of the applied magnetic field. These are not phases in the thermodynamic sense with critical properties but rather physical structures with different arrangements of the spins and hence different symmetries. We study the spatial symmetry of these phases, for the classical and quantum cases. Results are presented mainly for three frustrated systems, the triangle, the tetrahedron and the five-atom ring, which have many interesting features. In the classical limit we obtain phase diagrams in which some of the phase changes occur because of energy crossings and others due to energy bifurcations, corresponding to 'first-' and 'second-order' changes. In the quantum case we show how the symmetries of the states are related to the corresponding classical symmetries

  10. Autonomous Rendezvous and Docking with Nonfull Field of View for Tethered Space Robot

    Directory of Open Access Journals (Sweden)

    Panfeng Huang

    2017-01-01

    Full Text Available In the ultra-close approaching phase of tethered space robot, a highly stable self-attitude control is essential. However, due to the field of view limitation of cameras, typical point features are difficult to extract, where commonly adopted position-based visual servoing cannot be valid anymore. To provide robot’s relative position and attitude with the target, we propose a monocular visual servoing control method using only the edge lines of satellite brackets. Firstly, real time detection of edge lines is achieved based on image gradient and region growing. Then, we build an edge line based model to estimate the relative position and attitude between the robot and the target. Finally, we design a visual servoing controller combined with PD controller. Experimental results demonstrate that our algorithm can extract edge lines stably and adjust the robot’s attitude to satisfy the grasping requirements.

  11. Improved iris localization by using wide and narrow field of view cameras for iris recognition

    Science.gov (United States)

    Kim, Yeong Gon; Shin, Kwang Yong; Park, Kang Ryoung

    2013-10-01

    Biometrics is a method of identifying individuals by their physiological or behavioral characteristics. Among other biometric identifiers, iris recognition has been widely used for various applications that require a high level of security. When a conventional iris recognition camera is used, the size and position of the iris region in a captured image vary according to the X, Y positions of a user's eye and the Z distance between a user and the camera. Therefore, the searching area of the iris detection algorithm is increased, which can inevitably decrease both the detection speed and accuracy. To solve these problems, we propose a new method of iris localization that uses wide field of view (WFOV) and narrow field of view (NFOV) cameras. Our study is new as compared to previous studies in the following four ways. First, the device used in our research acquires three images, one each of the face and both irises, using one WFOV and two NFOV cameras simultaneously. The relation between the WFOV and NFOV cameras is determined by simple geometric transformation without complex calibration. Second, the Z distance (between a user's eye and the iris camera) is estimated based on the iris size in the WFOV image and anthropometric data of the size of the human iris. Third, the accuracy of the geometric transformation between the WFOV and NFOV cameras is enhanced by using multiple matrices of the transformation according to the Z distance. Fourth, the searching region for iris localization in the NFOV image is significantly reduced based on the detected iris region in the WFOV image and the matrix of geometric transformation corresponding to the estimated Z distance. Experimental results showed that the performance of the proposed iris localization method is better than that of conventional methods in terms of accuracy and processing time.

  12. Small-Field Dosimetry in A 6 MV Photon Beam Using Alanine and Liquid Ionisation Chamber

    DEFF Research Database (Denmark)

    Zimmermann, S.; Riis, H. L.; Hjelm-Hansen, M.

    2012-01-01

    Purpose/Objective: Dosimetry of small field sizes in MV photon beams is an increasingly important subject, and a generally accepted guideline for clinical measurements is still lacking. The present comparative study was carried out to further investigate the use of alanine and the PTW microLion...... of each field and depth. This dose maximum was measured for each field using a Scanditronix Wellhöfer photon field diode. The same measurements were carried out using a liquid ionchamber, PTW microLion, irradiated by 500 MU. The output of the accelerator was controlled by a PTW semiflex ion chamber...

  13. A 3D HIDAC-PET camera with sub-millimeter resolution for imaging small animals

    International Nuclear Information System (INIS)

    Jeavons, A.P.; Chandler, R.A.; Dettmar, C.A.R.

    1999-01-01

    A HIDAC-PET camera consisting essentially of 5 million 0.5 mm gas avalanching detectors has been constructed for small-animal imaging. The particular HIDAC advantage--a high 3D spatial resolution--has been improved to 0.95 mm fwhm and to 0.7 mm fwhm when reconstructing with 3D-OSEM methods incorporating resolution recovery. A depth-of-interaction resolution of 2.5 mm is implicit, due to the laminar construction. Scatter-corrected sensitivity, at 8.9 cps/kBq (i.e. 0.9%) from a central point source, or 7.2 cps/kBq (543 cps/kBq/cm 3 ) from a distributed (40 mm diameter, 60 mm long) source is now much higher than previous, and other, work. A field-of-view of 100 mm (adjustable to 200 mm) diameter by 210 mm axially permits whole-body imaging of small animals, containing typically 4MBqs of activity, at 40 kcps of which 16% are random coincidences, with a typical scatter fraction of 44%. Throughout the field-of-view there are no positional distortions and relative quantitation is uniform to ± 3.5%, but some variation of spatial resolution is found. The performance demonstrates that HIDAC technology is quite appropriate for small-animal PET cameras

  14. Estimation of extremely small field radiation dose for brain stereotactic radiotherapy using the Vero4DRT system.

    Science.gov (United States)

    Nakayama, Shinichi; Monzen, Hajime; Onishi, Yuichi; Kaneshige, Soichiro; Kanno, Ikuo

    2018-06-01

    The purpose of this study was a dosimetric validation of the Vero4DRT for brain stereotactic radiotherapy (SRT) with extremely small fields calculated by the treatment planning system (TPS) iPlan (Ver.4.5.1; algorithm XVMC). Measured and calculated data (e.g. percentage depth dose [PDD], dose profile, and point dose) were compared for small square fields of 30 × 30, 20 × 20, 10 × 10 and 5 × 5 mm 2 using ionization chambers of 0.01 or 0.04 cm 3 and a diamond detector. Dose verifications were performed using an ionization chamber and radiochromic film (EBT3; the equivalent field sizes used were 8.2, 8.7, 8.9, 9.5, and 12.9 mm 2 ) for five brain SRT cases irradiated with dynamic conformal arcs. The PDDs and dose profiles for the measured and calculated data were in good agreement for fields larger than or equal to 10 × 10 mm 2 when an appropriate detector was chosen. The dose differences for point doses in fields of 30 × 30, 20 × 20, 10 × 10 and 5 × 5 mm 2 were +0.48%, +0.56%, -0.52%, and +11.2% respectively. In the dose verifications for the brain SRT plans, the mean dose difference between the calculated and measured doses were -0.35% (range, -0.94% to +0.47%), with the average pass rates for the gamma index under the 3%/2 mm criterion being 96.71%, 93.37%, and 97.58% for coronal, sagittal, and axial planes respectively. The Vero4DRT system provides accurate delivery of radiation dose for small fields larger than or equal to 10 × 10 mm 2 . Copyright © 2018 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  15. Library based x-ray scatter correction for dedicated cone beam breast CT

    International Nuclear Information System (INIS)

    Shi, Linxi; Zhu, Lei; Vedantham, Srinivasan; Karellas, Andrew

    2016-01-01

    Purpose: The image quality of dedicated cone beam breast CT (CBBCT) is limited by substantial scatter contamination, resulting in cupping artifacts and contrast-loss in reconstructed images. Such effects obscure the visibility of soft-tissue lesions and calcifications, which hinders breast cancer detection and diagnosis. In this work, we propose a library-based software approach to suppress scatter on CBBCT images with high efficiency, accuracy, and reliability. Methods: The authors precompute a scatter library on simplified breast models with different sizes using the GEANT4-based Monte Carlo (MC) toolkit. The breast is approximated as a semiellipsoid with homogeneous glandular/adipose tissue mixture. For scatter correction on real clinical data, the authors estimate the breast size from a first-pass breast CT reconstruction and then select the corresponding scatter distribution from the library. The selected scatter distribution from simplified breast models is spatially translated to match the projection data from the clinical scan and is subtracted from the measured projection for effective scatter correction. The method performance was evaluated using 15 sets of patient data, with a wide range of breast sizes representing about 95% of general population. Spatial nonuniformity (SNU) and contrast to signal deviation ratio (CDR) were used as metrics for evaluation. Results: Since the time-consuming MC simulation for library generation is precomputed, the authors’ method efficiently corrects for scatter with minimal processing time. Furthermore, the authors find that a scatter library on a simple breast model with only one input parameter, i.e., the breast diameter, sufficiently guarantees improvements in SNU and CDR. For the 15 clinical datasets, the authors’ method reduces the average SNU from 7.14% to 2.47% in coronal views and from 10.14% to 3.02% in sagittal views. On average, the CDR is improved by a factor of 1.49 in coronal views and 2.12 in sagittal

  16. Library based x-ray scatter correction for dedicated cone beam breast CT

    Energy Technology Data Exchange (ETDEWEB)

    Shi, Linxi; Zhu, Lei, E-mail: leizhu@gatech.edu [Nuclear and Radiological Engineering and Medical Physics Programs, The George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, Georgia 30332 (United States); Vedantham, Srinivasan; Karellas, Andrew [Department of Radiology, University of Massachusetts Medical School, Worcester, Massachusetts 01655 (United States)

    2016-08-15

    Purpose: The image quality of dedicated cone beam breast CT (CBBCT) is limited by substantial scatter contamination, resulting in cupping artifacts and contrast-loss in reconstructed images. Such effects obscure the visibility of soft-tissue lesions and calcifications, which hinders breast cancer detection and diagnosis. In this work, we propose a library-based software approach to suppress scatter on CBBCT images with high efficiency, accuracy, and reliability. Methods: The authors precompute a scatter library on simplified breast models with different sizes using the GEANT4-based Monte Carlo (MC) toolkit. The breast is approximated as a semiellipsoid with homogeneous glandular/adipose tissue mixture. For scatter correction on real clinical data, the authors estimate the breast size from a first-pass breast CT reconstruction and then select the corresponding scatter distribution from the library. The selected scatter distribution from simplified breast models is spatially translated to match the projection data from the clinical scan and is subtracted from the measured projection for effective scatter correction. The method performance was evaluated using 15 sets of patient data, with a wide range of breast sizes representing about 95% of general population. Spatial nonuniformity (SNU) and contrast to signal deviation ratio (CDR) were used as metrics for evaluation. Results: Since the time-consuming MC simulation for library generation is precomputed, the authors’ method efficiently corrects for scatter with minimal processing time. Furthermore, the authors find that a scatter library on a simple breast model with only one input parameter, i.e., the breast diameter, sufficiently guarantees improvements in SNU and CDR. For the 15 clinical datasets, the authors’ method reduces the average SNU from 7.14% to 2.47% in coronal views and from 10.14% to 3.02% in sagittal views. On average, the CDR is improved by a factor of 1.49 in coronal views and 2.12 in sagittal

  17. Impact Angle and Time Control Guidance Under Field-of-View Constraints and Maneuver Limits

    Science.gov (United States)

    Shim, Sang-Wook; Hong, Seong-Min; Moon, Gun-Hee; Tahk, Min-Jea

    2018-04-01

    This paper proposes a guidance law which considers the constraints of seeker field-of-view (FOV) as well as the requirements on impact angle and time. The proposed guidance law is designed for a constant speed missile against a stationary target. The guidance law consists of two terms of acceleration commands. The first one is to achieve zero-miss distance and the desired impact angle, while the second is to meet the desired impact time. To consider the limits of FOV and lateral maneuver capability, a varying-gain approach is applied on the second term. Reduction of realizable impact times due to these limits is then analyzed by finding the longest course among the feasible ones. The performance of the proposed guidance law is demonstrated by numerical simulation for various engagement conditions.

  18. Predicting Motor Vehicle Collisions in a Driving Simulator in Young Adults Using the Useful Field of View Assessment.

    Science.gov (United States)

    McManus, Benjamin; Cox, Molly K; Vance, David E; Stavrinos, Despina

    2015-01-01

    Being involved in motor vehicle collisions is the leading cause of death in 1- to 34-year-olds, and risk is particularly high in young adults. The Useful Field of View (UFOV) task, a cognitive measure of processing speed, divided attention, and selective attention, has been shown to be predictive of motor vehicle collisions in older adults, but its use as a predictor of driving performance in a young adult population has not been investigated. The present study examined whether UFOV was a predictive measure of motor vehicle collisions in a driving simulator in a young adult population. The 3-subtest version of UFOV (lower scores measured in milliseconds indicate better performance) was administered to 60 college students. Participants also completed an 11-mile simulated drive to provide driving performance metrics. Findings suggested that subtests 1 and 2 suffered from a ceiling effect. UFOV subtest 3 significantly predicted collisions in the simulated drive. Each 30 ms slower on the subtest was associated with nearly a 10% increase in the risk of a simulated collision. Post hoc analyses revealed a small partially mediating effect of subtest 3 on the relationship between driving experience and collisions. The selective attention component of UFOV subtest 3 may be a predictive measure of crash involvement in a young adult population. Improvements in selective attention may be the underlying mechanism in how driving experience improves driving performance.

  19. Calibration of a dedicated software for 3D rendering

    Energy Technology Data Exchange (ETDEWEB)

    Abrantes, Marcos E.S.; Felix, Warley F.; Veloso, Maria Auxiliadora F., E-mail: marcos.nuclear@yahoo.com.br, E-mail: warleyferreirafelix@gmail.com, E-mail: mdora@nuclear.ufmg.br [Faculdade Ciencias Medicas de Minas Gerais (FCMMG), Belo Horizonte, MG (Brazil); Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Departamento de Engenharia Nuclear

    2017-11-01

    With the increasing use of 3D reconstruction techniques, to assist in diagnosis, dedicated programs are being widely used. For this they must be calibrated in order to encounter the values of the real volumes of the human tissues. The purpose of this work is to indicate correction and calibration values for true volumes, read in a 3D reconstruction system dedicated, using DICOM images of Computed Tomography. This work utilized a PMMA thorax phantom associated with the DICOM image and the volume found by a program of a tomograph. The physical volume of the PMMA phantom found was 10359.0 cm³. For the volumes found according to the structures of interest, the values are 11005.5 cm³, 10249.3 cm³ and 10205.1 cm³ and the correction values are -6.2%, +1.1% e +1.5% respectively for tissues: pulmonary, bony and soft tissues. The procedure performed can be used for calibration in other 3D reconstruction programs, observing the necessary corrections and the methodology used. (author)

  20. Calibration of a dedicated software for 3D rendering

    International Nuclear Information System (INIS)

    Abrantes, Marcos E.S.; Felix, Warley F.; Veloso, Maria Auxiliadora F.; Universidade Federal de Minas Gerais

    2017-01-01

    With the increasing use of 3D reconstruction techniques, to assist in diagnosis, dedicated programs are being widely used. For this they must be calibrated in order to encounter the values of the real volumes of the human tissues. The purpose of this work is to indicate correction and calibration values for true volumes, read in a 3D reconstruction system dedicated, using DICOM images of Computed Tomography. This work utilized a PMMA thorax phantom associated with the DICOM image and the volume found by a program of a tomograph. The physical volume of the PMMA phantom found was 10359.0 cm³. For the volumes found according to the structures of interest, the values are 11005.5 cm³, 10249.3 cm³ and 10205.1 cm³ and the correction values are -6.2%, +1.1% e +1.5% respectively for tissues: pulmonary, bony and soft tissues. The procedure performed can be used for calibration in other 3D reconstruction programs, observing the necessary corrections and the methodology used. (author)

  1. Minimizing Warehouse Space with a Dedicated Storage Policy

    Directory of Open Access Journals (Sweden)

    Andrea Fumi

    2013-07-01

    inevitably be supported by warehouse management system software. On the contrary, the proposed methodology relies upon a dedicated storage policy, which is easily implementable by companies of all sizes without the need for investing in expensive IT tools.

  2. Effective field theory approach to structure functions at small xBj

    International Nuclear Information System (INIS)

    Nachtmann, O.

    2003-01-01

    We relate the structure functions of deep inelastic lepton-nucleon scattering to current-current correlation functions in a Euclidean field theory depending on a parameter r. The r-dependent Hamiltonian of the theory is P 0 -(1-r)P 3 , with P 0 the usual Hamiltonian and P 3 the third component of the momentum operator. We show that a small x Bj in the structure functions corresponds to the small r limit of the effective theory. We argue that for r→0 there is a critical regime of the theory where simple scaling relations should hold. We show that in this framework Regge behaviour of the structure functions obtained with the hard pomeron ansatz corresponds to a scaling behaviour of the matrix elements in the effective theory where the intercept of the hard pomeron appears as a critical index. Explicit expressions for various analytic continuations of the structure functions and matrix elements are given as well as path integral representations for the matrix elements in the effective theory. Our aim is to provide a framework for truly non-perturbative calculations of the structure functions at small x Bj for arbitrary Q 2 . (orig.)

  3. Dedicated Filter for Robust Occupancy Grid Mapping

    Directory of Open Access Journals (Sweden)

    KS Nagla

    2015-03-01

    Full Text Available Sensor based perception of the environment is an emerging area of the mobile robot research where sensors play a pivotal role. For autonomous mobile robots, the fundamental requirement is the convergent of the range information in to high level internal representation. Internal representation in the form of occupancy grid is commonly used in autonomous mobile robots due to its various advantages. There are several sensors such as vision sensor, laser rage finder, and ultrasonic and infrared sensors etc. play roles in mapping. However the sensor information failure, sensor inaccuracies, noise, and slow response are the major causes of an error in the mapping. To improve the reliability of the mobile robot mapping multisensory data fusion is considered as an optimal solution. This paper presents a novel architecture of sensor fusion frame work in which a dedicated filter (DF is proposed to increase the robustness of the occupancy grid for indoor environment. The technique has been experimentally verified for different indoor test environments. The proposed configuration shows improvement in the occupancy grid with the implementation of dedicated filters.

  4. SU-F-T-367: Using PRIMO, a PENELOPE-Based Software, to Improve the Small Field Dosimetry of Linear Accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Benmakhlouf, H; Andreo, P [Department of Medical Physics, Karolinska University Hospital (Sweden); Brualla, L [NCTeam, Strahlenklinik, Universitatsklinikum Essen (Germany); Sempau, J [Institut de Tecniques Energetiques, Universitat Politecnica de Catalunya (Spain)

    2016-06-15

    Purpose: To calculate output correction factors for Varian Clinac 2100iX beams for seven small field detectors and use the values to determine the small field output factors for the linacs at Karolinska university hospital. Methods: Phase space files (psf) for square fields between 0.25cm and 10cm were calculated using the PENELOPE-based PRIMO software. The linac MC-model was tuned by comparing PRIMO-estimated and experimentally determined depth doses and lateral dose-profiles for 40cmx40cm fields. The calculated psf were used as radiation sources to calculate the correction factors of IBA and PTW detectors with the code penEasy/PENELOPE. Results: The optimal tuning parameters of the MClinac model in PRIMO were 5.4 MeV incident electron energy and zero energy spread, focal spot size and beam divergence. Correction factors obtained for the liquid ion chamber (PTW-T31018) are within 1% down to 0.5 cm fields. For unshielded diodes (IBA-EFD, IBA-SFD, PTW-T60017 and PTW-T60018) the corrections are up to 2% at intermediate fields (>1cm side), becoming down to −11% for fields smaller than 1cm. The shielded diode (IBA-PFD and PTW-T60016) corrections vary with field size from 0 to −4%. Volume averaging effects are found for most detectors in the presence of 0.25cm fields. Conclusion: Good agreement was found between correction factors based on PRIMO-generated psf and those from other publications. The calculated factors will be implemented in output factor measurements (using several detectors) in the clinic. PRIMO is a userfriendly general code capable of generating small field psf and can be used without having to code own linac geometries. It can therefore be used to improve the clinical dosimetry, especially in the commissioning of linear accelerators. Important dosimetry data, such as dose-profiles and output factors can be determined more accurately for a specific machine, geometry and setup by using PRIMO and having a MC-model of the detector used.

  5. Persistent detwinning of EuFe{sub 2}As{sub 2} by small magnetic fields

    Energy Technology Data Exchange (ETDEWEB)

    Maiwald, Jannis; Stingl, Christian; Bach, Nora; Jeevan, H.S.; Gegenwart, Philipp [Experimentalphysik VI, Universitaet Augsburg (Germany); Zapf, Sina; Jiang, Shuai; Neubauer, David; Loehle, Anja; Clauss, Conrad; Dressel, Martin [1. Physikalisches Institut, Universitaet Stuttgart (Germany); Post, Kirk; Basov, Dimitri [Department of Physics, UC San Diego (United States)

    2015-07-01

    The formation of twin domains in the orthorhombic phase of high-temperature superconductors is impeding the investigation of the in-plane anisotropy of these materials. Recently, we have shown how the brief application of a small magnetic field of ∝ 1 Tesla in the EuFe{sub 2}As{sub 2} iron pnictide leads to a substantial detwinning of the system, which is persistent up to the structural transition at ∝ 190 K even after the magnetic field has been switched off. This offers researchers the opportunity to investigate the detwinned iron arsenide without the application of any external symmetry breaking force, like the pressure of a mechanical clamp, or a magnetic field present during measurement. We will present angular dependent magnetoresistance, magnetostriction, thermal expansion and thermoelectric power measurements on the EuFe{sub 2}As{sub 2} parent compound as well as on various doped variants in order to shed further light on the mechanism behind the field induced detwinning, i.e. the interplay of the involved magnetic moments stemming form the Eu and Fe atoms in these compounds.

  6. Evaluation of the dose calculation accuracy for small fields defined by jaw or MLC for AAA and Acuros XB algorithms.

    Science.gov (United States)

    Fogliata, Antonella; Lobefalo, Francesca; Reggiori, Giacomo; Stravato, Antonella; Tomatis, Stefano; Scorsetti, Marta; Cozzi, Luca

    2016-10-01

    Small field measurements are challenging, due to the physical characteristics coming from the lack of charged particle equilibrium, the partial occlusion of the finite radiation source, and to the detector response. These characteristics can be modeled in the dose calculations in the treatment planning systems. Aim of the present work is to evaluate the MU calculation accuracy for small fields, defined by jaw or MLC, for anisotropic analytical algorithm (AAA) and Acuros XB algorithms, relative to output measurements on the beam central axis. Single point output factor measurement was acquired with a PTW microDiamond detector for 6 MV, 6 and 10 MV unflattened beams generated by a Varian TrueBeam STx equipped with high definition-MLC. Fields defined by jaw or MLC apertures were set; jaw-defined: 0.6 × 0.6, 0.8 × 0.8, 1 × 1, 2 × 2, 3 × 3, 4 × 4, 5 × 5, and 10 × 10 cm 2 ; MLC-defined: 0.5 × 0.5 cm 2 to the maximum field defined by the jaw, with 0.5 cm stepping, and jaws set to: 2 × 2, 3 × 3, 4 × 4, 5 × 5, and 10 × 10 cm 2 . MU calculation was obtained with 1 mm grid in a virtual water phantom for the same fields, for AAA and Acuros algorithms implemented in the Varian eclipse treatment planning system (version 13.6). Configuration parameters as the effective spot size (ESS) and the dosimetric leaf gap (DLG) were varied to find the best parameter setting. Differences between calculated and measured doses were analyzed. Agreement better than 0.5% was found for field sizes equal to or larger than 2 × 2 cm 2 for both algorithms. A dose overestimation was present for smaller jaw-defined fields, with the best agreement, averaged over all the energies, of 1.6% and 4.6% for a 1 × 1 cm 2 field calculated by AAA and Acuros, respectively, for a configuration with ESS = 1 mm for both X and Y directions for AAA, and ESS = 1.5 and 0 mm for X and Y directions for Acuros. Conversely, a calculated dose underestimation was found for small MLC-defined fields, with the

  7. Design of an electrically small circularly polarised turnstile antenna and its application to near-field wireless power transfer

    DEFF Research Database (Denmark)

    Yoon, Ick-Jae; Ling, Hao

    2014-01-01

    An electrically small circularly polarised antenna is designed and applied to near-field wireless power transfer as a means of alleviating orientation dependence. The antenna is miniaturised from a spl lambda//2-turnstile antenna by utilising the top loading and multiple folding techniques. A loc...... performance is verified in the far field. The power transfer efficiency is then examined in the near field via simulation and measurement. It is shown that the designed circularly polarised antenna is effective in mitigating orientation dependence down to a distance of 0.2λ.......An electrically small circularly polarised antenna is designed and applied to near-field wireless power transfer as a means of alleviating orientation dependence. The antenna is miniaturised from a spl lambda//2-turnstile antenna by utilising the top loading and multiple folding techniques. A local...... numerical search is used to determine the optimal antenna dimensions to achieve good axial ratio and impedance matching. The resulting design has a kr of 0.67 and shows good circular polarisation characteristic with a 3% axial ratio bandwidth. The designed antenna is fabricated and its circular polarisation...

  8. Optimized Watermarking for Light Field Rendering based Free-View TV

    DEFF Research Database (Denmark)

    Apostolidis, Evlampios; Kounalakis, Tsampikos; Manifavas, Charalampos

    2013-01-01

    In Free-View Television the viewers select freely the viewing position and angle of the transmitted multiview video. It is apparent that copyright and copy protection problems exist, since a video of this arbitrarily selected view can be recorded and then misused. In this context, the watermark...... introduced by the watermark’s insertion-extraction scheme. Therefore, we ended up to the best five Mathematical Distributions, and we concluded that the watermark’s robustness in FTV case does not depend only on the FTV image’s characteristics, but it also relies on the characteristics of the Mathematical...

  9. The photospheric vector magnetic field of a sunspot and its vertical gradient

    Science.gov (United States)

    Hagyard, M. J.; West, E. A.; Tandberg-Hanssen, E.; Smith, J. E.; Henze, W., Jr.; Beckers, J. M.; Bruner, E. C.; Hyder, C. L.; Gurman, J. B.; Shine, R. A.

    1981-01-01

    The results of direct comparisons of photospheric and transition region line-of-sight field observations of sunspots using the SMM UV spectrometer and polarimeter are reported. The analysis accompanying the data is concentrated on demonstrating that the sunspot concentrated magnetic field extends into the transition region. An observation of a sunspot on Oct. 23, 1980 at the S 18 E 03 location is used as an example. Maximum field strengths ranged from 2030-2240 gauss for large and small umbrae viewed and inclination of the field to the line-of-sight was determined for the photosphere and transition region. The distribution of the magnetic field over the sunspot and variation of the line-of-sight gradient are discussed, as are the magnitudes and gradients of the photospheric field across the penumbral-photospheric boundaries.

  10. Don't Forget About Dedicated Sea Mine Countermeasures

    National Research Council Canada - National Science Library

    Potts, Malcolm H

    2005-01-01

    .... Struggling through the Korean Conflict, the U.S. Navy began a slow improvement of MCM forces leading up to the first Gulf War where experiences led to the conclusion that a well equipped dedicated MCM force structure is essential...

  11. A two-dimensional liquid-filled ionization chamber array prototype for small-field verification: characterization and first clinical tests

    International Nuclear Information System (INIS)

    Brualla-González, Luis; Vicedo, Aurora; Roselló, Joan V; Gómez, Faustino; González-Castaño, Diego M; Gago-Arias, Araceli; Pazos, Antonio; Zapata, Martín; Pardo-Montero, Juan

    2012-01-01

    In this work we present the design, characterization and first clinical tests of an in-house developed two-dimensional liquid-filled ionization chamber prototype for the verification of small radiotherapy fields and treatments containing such small fields as in radiosurgery, which consists of 2 mm × 2 mm pixels arranged on a 16×8 rectangular grid. The ionization medium is isooctane. The characterization of the device included the study of depth, field-size and dose-rate dependences, which are sufficiently moderate for a good operation at therapy radiation levels. However, the detector presents an important anisotropic response, up to ≃ 12% for front versus near-lateral incidence, which can impact the verification of full treatments with different incidences. In such a case, an anisotropy correction factor can be applied. Output factors of small square fields measured with the device show a small systematic over-response, less than 1%, when compared to unshielded diode measurements. An IMRT radiosurgery treatment has been acquired with the liquid-filled ionization chamber device and compared with film dosimetry by using the gamma method, showing good agreement: over 99% passing rates for 1.2% and 1.2 mm for an incidence-per-incidence analysis; 100% passing rates for tolerances 1.8% and 1.8 mm when the whole treatment is analysed and the anisotropy correction factor is applied. The point dose verification for each incidence of the treatment performed with the liquid-filled ionization chamber agrees within 1% with a CC01 ionization chamber. This prototype has shown the utility of this kind of technology for the verification of small fields/treatments. Currently, a larger device covering a 5 cm × 5 cm area is under development. (paper)

  12. A 3D high-resolution gamma camera for radiopharmaceutical studies with small animals

    CERN Document Server

    Loudos, G K; Giokaris, N D; Styliaris, E; Archimandritis, S C; Varvarigou, A D; Papanicolas, C N; Majewski, S; Weisenberger, D; Pani, R; Scopinaro, F; Uzunoglu, N K; Maintas, D; Stefanis, K

    2003-01-01

    The results of studies conducted with a small field of view tomographic gamma camera based on a Position Sensitive Photomultiplier Tube are reported. The system has been used for the evaluation of radiopharmaceuticals in small animals. Phantom studies have shown a spatial resolution of 2 mm in planar and 2-3 mm in tomographic imaging. Imaging studies in mice have been carried out both in 2D and 3D. Conventional radiopharmaceuticals have been used and the results have been compared with images from a clinically used system.

  13. Promoting small towns for rural development: a view from Nepal.

    Science.gov (United States)

    Bajracharya, B N

    1995-06-01

    Two small villages in Nepal are the subjects of case studies that illustrate the role of small towns in provision of services, employment, and market operations. Some general findings are that small towns act as service centers for distribution of basic essential goods such as food grains, salt, kerosene, and fabric for hill and mountain areas. The role of small towns as market centers and in the provision of employment is limited. In resource-poor areas small towns are less diversified. Towns with agricultural surpluses are more developed. Small hill towns satisfy consumption rather than production needs. The growth of rural areas and towns in rural areas in Nepal is dependent on arable land and levels of production in hill areas. Limited land and low levels of production have an adverse impact. Movement of people, goods, and services is limited by difficult terrain and lack of access to good roads. Variability in access to off-farm jobs and services available in small towns varies with ethnicity and place of residence. The best development strategy for small towns in Nepal is market-oriented territorial development, which retains surpluses in the local area and integrates markets in the larger economy. The strategy would decentralize planning into small territorial units that include both small towns and groups of villages, provide institutional support for the rural poor, expand off-farm employment, and include investment in region-serving functions. Subsistence agriculture needs to include diversification of high value cash crops based on local comparative advantage suitable for hill climate and terrain. Small farmers must produce both cash and subsistence crops. Government should provide market space and paved areas, weighing facilities, and overnight storage facilities. Products would be processed at the village level. Subdistricts must be established according to spatial and social linkages between villages and the service center and coordinated at the

  14. Exploiting Performance of Different Low-Cost Sensors for Small Amplitude Oscillatory Motion Monitoring: Preliminary Comparisons in View of Possible Integration

    Directory of Open Access Journals (Sweden)

    Elisa Benedetti

    2016-01-01

    Full Text Available We address the problem of low amplitude oscillatory motion detection through different low-cost sensors: a LIS3LV02DQ MEMS accelerometer, a Microsoft Kinect v2 range camera, and a uBlox 6 GPS receiver. Several tests were performed using a one-direction vibrating table with different oscillation frequencies (in the range 1.5–3 Hz and small challenging amplitudes (0.02 m and 0.03 m. A Mikrotron EoSens high-resolution camera was used to give reference data. A dedicated software tool was developed to retrieve Kinect v2 results. The capabilities of the VADASE algorithm were employed to process uBlox 6 GPS receiver observations. In the investigated time interval (in the order of tens of seconds the results obtained indicate that displacements were detected with the resolution of fractions of millimeters with MEMS accelerometer and Kinect v2 and few millimeters with uBlox 6. MEMS accelerometer displays the lowest noise but a significant bias, whereas Kinect v2 and uBlox 6 appear more stable. The results suggest the possibility of sensor integration both for indoor (MEMS accelerometer + Kinect v2 and for outdoor (MEMS accelerometer + uBlox 6 applications and seem promising for structural monitoring applications.

  15. Virginia Tech's College Of Natural Resources Dedicates Cheatham Hall Expansion

    OpenAIRE

    Davis, Lynn

    2003-01-01

    Thanks to funding by private donors, Alyce Cheatham and her family of Portland, Oregon, Virginia Tech's College of Natural Resources will dedicate a much-needed, three-story addition to its current Cheatham Hall on Wednesday, March 19, at 2:30 p.m.

  16. Foucault imaging and small-angle electron diffraction in controlled external magnetic fields.

    Science.gov (United States)

    Nakajima, Hiroshi; Kotani, Atsuhiro; Harada, Ken; Ishii, Yui; Mori, Shigeo

    2016-12-01

    We report a method for acquiring Foucault images and small-angle electron diffraction patterns in external magnetic fields using a conventional transmission electron microscope without any modification. In the electron optical system that we have constructed, external magnetic fields parallel to the optical axis can be controlled using the objective lens pole piece under weak excitation conditions in the Foucault mode and the diffraction mode. We observe two ferromagnetic perovskite-type manganese oxides, La 0.7 Sr 0.3 MnO 3 (LSMO) and Nd 0.5 Sr 0.5 MnO 3 , in order to visualize magnetic domains and their magnetic responses to external magnetic fields. In rhombohedral-structured LSMO, pinning of magnetic domain walls at crystallographic twin boundaries was found to have a strong influence on the generation of new magnetic domains in external applied magnetic fields. © The Author 2016. Published by Oxford University Press on behalf of The Japanese Society of Microscopy. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  17. Field of View Requirements for Carrier Landing Training

    Science.gov (United States)

    1980-06-01

    descent is guided by the Fresnel Lens Optical Landing System,(FLOLS) which displays a vertically moveable center iight beam (the " meatball ") which...must be kept aligned with rows of stationary horizontal lights. When the aircraft is above or below the correct glideslope, the meatball is seen as above...or below the horizontal reference lights. If the pilot is viewing a centered meatball , and if the aircraft has the correct AOA, the tailhook will be

  18. Observations of photospheric magnetic fields and shear flows in flaring active regions

    International Nuclear Information System (INIS)

    Tarbell, T.; Ferguson, S.; Frank, Z.; Title, A.; Topka, K.

    1988-01-01

    Horizontal flows in the photosphere and subsurface convection zone move the footpoints of coronal magnetic field lines. Magnetic energy to power flares can be stored in the corona if the flows drive the fields far from the potential configuration. Videodisk movies were shown with 0.5 to 1 arcsecond resolution of the following simultaneous observations: green continuum, longitudinal magnetogram, Fe I 5576 A line center (mid-photosphere), H alpha wings, and H alpha line center. The movies show a 90 x 90 arcsecond field of view of an active region at S29, W11. When viewed at speeds of a few thousand times real-time, the photospheric movies clearly show the active region fields being distorted by a remarkable combination of systematic flows and small eruptions of new flux. Magnetic bipoles are emerging over a large area, and the polarities are systematically flowing apart. The horizontal flows were mapped in detail from the continuum movies, and these may be used to predict the future evolution of the region. The horizontal flows are not discernable in H alpha. The H alpha movies strongly suggest reconnection processes in the fibrils joining opposite polarities. When viewed in combination with the magnetic movies, the cause for this evolution is apparent: opposite polarity fields collide and partially cancel, and the fibrils reconnect above the surface. This type of reconnection, driven by subphotospheric flows, complicates the chromospheric and coronal fields, causing visible braiding and twisting of the fibrils. Some of the transient emission events in the fibrils and adjacent plage may also be related

  19. Sci—Fri AM: Mountain — 01: Validation of a new formulism and the related correction factors on output factor determination for small photon fields

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Yizhen; Younge, Kelly; Nielsen, Michelle; Mutanga, Theodore [Peel Regional Cancer Center, Trillium Health Partners, Mississauga, ON (Canada); Cui, Congwu [Peel Regional Cancer Center, Trillium Health Partners, Mississauga, ON (Canada); Department of Radiation Oncology, University of Toronto, Toronto, ON (Canada); Das, Indra J. [Radiation Oncology Dept., Indiana University- School of Medicine, Indianapolis, IN (United States)

    2014-08-15

    Small field dosimetry measurements including output factors are difficult due to lack of charged-particle equilibrium, occlusion of the radiation source, the finite size of detectors, and non-water equivalence of detector components. With available detectors significant variations could be measured that will lead to incorrect delivered dose to patients. IAEA/AAPM have provided a framework and formulation to correct the detector response in small photon fields. Monte Carlo derived correction factors for some commonly used small field detectors are now available, however validation has not been performed prior to this study. An Exradin A16 chamber, EDGE detector and SFD detector were used to perform the output factor measurement for a series of conical fields (5–30mm) on a Varian iX linear accelerator. Discrepancies up to 20%, 10% and 6% were observed for 5, 7.5 and 10 mm cones between the initial output factors measured by the EDGE detector and the A16 ion chamber, while the discrepancies for the conical fields larger than 10 mm were less than 4%. After the application of the correction, the output factors agree well with each other to within 1%. Caution is needed when determining the output factors for small photon fields, especially for fields 10 mm in diameter or smaller. More than one type of detector should be used, each with proper corrections applied to the measurement results. It is concluded that with the application of correction factors to appropriately chosen detectors, output can be measured accurately for small fields.

  20. Scintillator performance considerations for dedicated breast computed tomography

    Science.gov (United States)

    Vedantham, Srinivasan; Shi, Linxi; Karellas, Andrew

    2017-09-01

    Dedicated breast computed tomography (BCT) is an emerging clinical modality that can eliminate tissue superposition and has the potential for improved sensitivity and specificity for breast cancer detection and diagnosis. It is performed without physical compression of the breast. Most of the dedicated BCT systems use large-area detectors operating in cone-beam geometry and are referred to as cone-beam breast CT (CBBCT) systems. The large-area detectors in CBBCT systems are energy-integrating, indirect-type detectors employing a scintillator that converts x-ray photons to light, followed by detection of optical photons. A key consideration that determines the image quality achieved by such CBBCT systems is the choice of scintillator and its performance characteristics. In this work, a framework for analyzing the impact of the scintillator on CBBCT performance and its use for task-specific optimization of CBBCT imaging performance is described.