WorldWideScience

Sample records for sites displaces ct-rsf

  1. The RSF1 histone-remodelling factor facilitates DNA double-strand break repair by recruiting centromeric and Fanconi Anaemia proteins.

    Directory of Open Access Journals (Sweden)

    Fabio Pessina

    2014-05-01

    Full Text Available ATM is a central regulator of the cellular responses to DNA double-strand breaks (DSBs. Here we identify a biochemical interaction between ATM and RSF1 and we characterise the role of RSF1 in this response. The ATM-RSF1 interaction is dependent upon both DSBs and ATM kinase activity. Together with SNF2H/SMARCA5, RSF1 forms the RSF chromatin-remodelling complex. Although RSF1 is specific to the RSF complex, SNF2H/SMARCA5 is a catalytic subunit of several other chromatin-remodelling complexes. Although not required for checkpoint signalling, RSF1 is required for efficient repair of DSBs via both end-joining and homology-directed repair. Specifically, the ATM-dependent recruitment to sites of DSBs of the histone fold proteins CENPS/MHF1 and CENPX/MHF2, previously identified at centromeres, is RSF1-dependent. In turn these proteins recruit and regulate the mono-ubiquitination of the Fanconi Anaemia proteins FANCD2 and FANCI. We propose that by depositing CENPS/MHF1 and CENPX/MHF2, the RSF complex either directly or indirectly contributes to the reorganisation of chromatin around DSBs that is required for efficient DNA repair.

  2. Research Support Facility (RSF): Leadership in Building Performance (Brochure)

    Energy Technology Data Exchange (ETDEWEB)

    2011-09-01

    This brochure/poster provides information on the features of the Research Support Facility including a detailed illustration of the facility with call outs of energy efficiency and renewable energy technologies. Imagine an office building so energy efficient that its occupants consume only the amount of energy generated by renewable power on the building site. The building, the Research Support Facility (RSF) occupied by the U.S. Department of Energy's National Renewable Energy Laboratory (NREL) employees, uses 50% less energy than if it were built to current commercial code and achieves the U.S. Green Building Council's Leadership in Energy and Environmental Design (LEED{reg_sign}) Platinum rating. With 19% of the primary energy in the U.S. consumed by commercial buildings, the RSF is changing the way commercial office buildings are designed and built.

  3. Rsf-1 is overexpressed in non-small cell lung cancers and regulates cyclinD1 expression and ERK activity

    International Nuclear Information System (INIS)

    Li, Qingchang; Dong, Qianze; Wang, Enhua

    2012-01-01

    Highlights: ► Rsf-1 expression is elevated in non-small cell lung cancers. ► Rsf-1 depletion inhibits proliferation and increased apoptosis in lung cancer cells. ► Rsf-1 depletion decreases the level of cyclinD1 and phosphor-ERK expression. -- Abstract: Rsf-1 (HBXAP) was recently reported to be overexpressed in various cancers and associated with the malignant behavior of cancer cells. However, the expression of Rsf-1 in primary lung cancer and its biological roles in non-small cell lung cancer (NSCLC) have not been reported. The molecular mechanism of Rsf-1 in cancer aggressiveness remains ambiguous. In the present study, we analyzed the expression pattern of Rsf-1 in NSCLC tissues and found that Rsf-1 was overexpressed at both the mRNA and protein levels. There was a significant association between Rsf-1 overexpression and TNM stage (p = 0.0220) and poor differentiation (p = 0.0013). Furthermore, knockdown of Rsf-1 expression in H1299 and H460 cells with high endogenous Rsf-1 expression resulted in a decrease of colony formation ability and inhibition of cell cycle progression. Rsf-1 knockdown also induced apoptosis in these cell lines. Further analysis showed that Rsf-1 knockdown decreased cyclin D1 expression and phospho-ERK levels. In conclusion, Rsf-1 is overexpressed in NSCLC and contributes to malignant cell growth by cyclin D1 and ERK modulation, which makes Rsf-1 a candidate therapeutic target in lung cancer.

  4. Arterial displacement by the tumor demonstrated by magnetic resonance CT

    International Nuclear Information System (INIS)

    Tsuchiya, Kazuhiro; Yoshikawa, Kohki; Machida, Tohru; Iio, Masahiro.

    1985-01-01

    MR-CT permits visualization of blood vessels non-invasively. Major blood vessels in scan slices are demonstrated as structures with low or no signal intensity. In this report, two cases with brain tumor and spinal tumor are presented in which arterial displacement by the tumor was visualized by MR-CT. MR-CT is considered to be an effective method in detecting blood vessel abnormalities. (author)

  5. Multiplanar CT assessment of femoral head displacement in slipped capital femoral epiphysis

    Energy Technology Data Exchange (ETDEWEB)

    Monazzam, Shafagh [Rady Children' s Hospital and Health Center, Department of Orthopedics, San Diego, CA (United States); Dwek, Jerry R. [Rady Children' s Hospital and Health Center, Department of Radiology, San Diego, CA (United States); Hosalkar, Harish S. [Center for Hip Preservation, Department of Orthopedic Surgery, TriCity Medical Center, Oceanside, CA (United States)

    2013-12-15

    With recent changing approaches to the management of slipped capital femoral epiphysis (SCFE), the accurate radiographic assessment of maximum extent of displacement is crucial for planning surgical treatment. To determine what plane best represents the maximum SCFE displacement as quantified by the head-neck angle difference (HNAD), whether HNAD can quantitatively differentiate the SCFE cohort from the normal cohort, based on CT, and how Southwick slip angle (SSA) compares to HNAD. We reviewed 19 children with SCFE (23 affected hips) with preoperative CT scans and 27 age- and sex-matched children undergoing abdominal CT for non-orthopedic problems. Head-neck angle (HNA), the angle between the femoral epiphysis and the neck axis, was measured in three planes on each hip and the HNAD (affected - unaffected hip) was determined. SSA was measured on radiographs. The coronal HNAD (mean 8.7 ) was less than both the axial-oblique (mean 30.7 ) and sagittal (mean 37.4 ) HNADs, which were also greater than the HNADs of the normal cohort. Grouping HNAD measurements by SSA severity classification did not consistently distinguish between SCFE severity levels. Axial-oblique and sagittal planes best represent the maximum SCFE displacement while biplanar radiograph may underestimate the extent of the displacement, thereby potentially altering the management between in situ pinning and capital realignment. (orig.)

  6. Lateral displacement of the right kidney by the colon: an anatomic variation demonstrated by CT

    International Nuclear Information System (INIS)

    Silverman, P.M.; Kelvin, F.M.; Korobkin, M.

    1983-01-01

    Lateral displacement of the kidney on a urogram can be caused by a variety of retroperitoneal abnormalities, including enlarged lymph nodes, primary or metastatic neoplasm, aortic aneurysm, hematoma, abscess, or even benign accumulations of fat. CT commonly is used to evaluate the cause of renal displacement and often suggests the correct etiology. An unusual case is reported in which CT demonstrated that lateral displacement of the right kidney was caused by insinuation of an otherwise normal right colon between the kidney and the right psoas muscle. The authors are not aware of any previous report of this benign anatomic variant

  7. Dendritic cells transduced with Rsf-1/HBXAP gene generate specific cytotoxic T lymphocytes against ovarian cancer in vitro

    International Nuclear Information System (INIS)

    Sun, Li; Kong, Beihua; Sheng, Xiugui; Sheu, Jim Jinn-Chyuan; Shih, Ie-Ming

    2010-01-01

    Recently, some studies have indicated that Rsf-1/HBXAP plays a role in chromatin remodeling and transcriptional regulation that may contribute to tumorigenesis in ovarian cancer. The present study demonstrates that using dendritic cells (DCs) from human cord blood CD34 + cells transduced with Rsf-1/HBXAP DNA plasmids by nucleofection generate specific cytotoxic T lymphocytes (CTL) against ovarian cancer in vitro. After transfection, DCs were analyzed for Rsf-1/HBXAP mRNA expression by RT-PCR and protein expression by Western blot. Then the DC phenotypes, T-cell stimulatory capacity, endocytic activity and migration capacity were explored by flow cytometry analysis, allogeneic mixed lymphocyte reaction, endocytosis and transwell chemotaxis assay, respectively. After transfection, Rsf-1/HBXAP expression was detected at mRNA and protein levels. Allogeneic T-cell proliferation induced by transfected DCs was obviously higher than non-transfected DCs, but the endocytosis capacity and migratory ability were not different. Rsf-1/HBXAP gene-transduced DCs could induce antigen-specific CTL and generate a very potent cytotoxicity to OVCAR3 cells. These data suggest that Rsf-1/HBXAP gene-transduced DCs may be a potential adjuvant immunotherapy for ovarian cancer in clinical applications.

  8. Design-Build Process for the Research Support Facility (RSF) (Book)

    Energy Technology Data Exchange (ETDEWEB)

    2012-06-01

    An in-depth look at how the U.S. DOE and NREL used a performance-based design-build contract to build the Research Support Facility (RSF); one of the most energy efficient office buildings in the world.

  9. Construction of stably maintained non-mobilizable derivatives of RSF1010 lacking all known elements essential for mobilization

    Directory of Open Access Journals (Sweden)

    Tokmakova Irina L

    2007-11-01

    Full Text Available Abstract Background RSF1010 is a well-studied broad-host-range plasmid able to be mobilized to different bacteria and plants. RSF1010-derived plasmid vectors are widely used in both basic research and industrial applications. In the latter case, exploiting of mobilizable plasmids or even the plasmids possessing negligible mobilization frequency, but containing DNA fragments that could promote conjugal transfer, is undesirable because of biosafety considerations. Previously, several mutations significantly decreasing efficiency of RSF1010 mobilization have been selected. Nevertheless, construction of the RSF1010 derivative lacking all known loci involved in the conjugal transfer has not been reported yet. Results Novel non-mobilizable derivatives of RSF1010 lacking all known DNA sequences involved in the mobilization process have been obtained due to the exploiting of λRed-driven recombination between the plasmid and a constructed in vitro linear DNA fragment. To provide auto-regulated transcription of the essential replication gene, repB, the plasmid loci oriT, mobC and mobA were substituted by the DNA fragment containing PlacUV5→lacI. Mobilization of the obtained RSFmob plasmid was not detected in standard tests. The derivative of RSFmob with increased copy number has been obtained after lacI elimination. High stability of both constructed plasmids has been demonstrated in Escherichia coli and Pantoea ananatis. Design of RSFmob allows easy substitution of PlacUV5 by any desirable promoter for construction of novel derivatives with changed copy number or host range. Conclusion Novel non-mobilizable derivatives of RSF1010 lacking all known DNA sequences involved in the mobilization process and stably maintained at least in E. coli and P. ananatis have been constructed. The obtained plasmids became the progenitors of new cloning vectors answering all biosafety requirements of genetically modified organisms used in scale-up production.

  10. Three-dimensional patient setup errors at different treatment sites measured by the Tomotherapy megavoltage CT

    Energy Technology Data Exchange (ETDEWEB)

    Hui, S.K.; Lusczek, E.; Dusenbery, K. [Univ. of Minnesota Medical School, Minneapolis, MN (United States). Dept. of Therapeutic Radiology - Radiation Oncology; DeFor, T. [Univ. of Minnesota Medical School, Minneapolis, MN (United States). Biostatistics and Informatics Core; Levitt, S. [Univ. of Minnesota Medical School, Minneapolis, MN (United States). Dept. of Therapeutic Radiology - Radiation Oncology; Karolinska Institutet, Stockholm (Sweden). Dept. of Onkol-Patol

    2012-04-15

    Reduction of interfraction setup uncertainty is vital for assuring the accuracy of conformal radiotherapy. We report a systematic study of setup error to assess patients' three-dimensional (3D) localization at various treatment sites. Tomotherapy megavoltage CT (MVCT) images were scanned daily in 259 patients from 2005-2008. We analyzed 6,465 MVCT images to measure setup error for head and neck (H and N), chest/thorax, abdomen, prostate, legs, and total marrow irradiation (TMI). Statistical comparisons of the absolute displacements across sites and time were performed in rotation (R), lateral (x), craniocaudal (y), and vertical (z) directions. The global systematic errors were measured to be less than 3 mm in each direction with increasing order of errors for different sites: H and N, prostate, chest, pelvis, spine, legs, and TMI. The differences in displacements in the x, y, and z directions, and 3D average displacement between treatment sites were significant (p < 0.01). Overall improvement in patient localization with time (after 3-4 treatment fractions) was observed. Large displacement (> 5 mm) was observed in the 75{sup th} percentile of the patient groups for chest, pelvis, legs, and spine in the x and y direction in the second week of the treatment. MVCT imaging is essential for determining 3D setup error and to reduce uncertainty in localization at all anatomical locations. Setup error evaluation should be performed daily for all treatment regions, preferably for all treatment fractions. (orig.)

  11. Effects of alveolar bone displacement with segmental osteotomy: micro-CT and histomorphometric analysis in rats

    Directory of Open Access Journals (Sweden)

    Taegun KIM

    Full Text Available Abstract The purpose of this study was to evaluate the effects of segmental osteotomy on the blood vessels and osteoclasts in rats using micro-computed tomography (micro-CT and histomorphometric analysis. After segmental osteotomy was performed around the maxillary first molars of 36 male Sprague-Dawley rats (n = 72, the samples were divided into a control group (no displacement, 0.5 D group (0.5 mm buccal displacement and 1.0 D group (1.0 mm buccal displacement (n = 24/group. At 1, 2, 4 and 8 weeks after surgery, changes in the blood vessel volume were investigated using micro-CT with perfusion of radiopaque silicone rubber. Tartrate-resistant acid phosphatase (TRAP staining was used for histomorphometric analysis. Two-way repeated measures analysis of variance (rmANOVA was performed to compare the volume of blood vessels and number of TRAP-positive osteoclasts among the groups. Regarding blood vessel volume, the displacement groups had no significant effects, while the time points had significant effects (p = 0.014. The blood vessel volume at 1 week was significantly smaller than that at 2, 4, and 8 weeks (p = 0.004, p = 0.026, and p = 0.005, respectively. Regarding TRAP cell count, the displacement groups had no significant effects, while the time points had significant effects (p < 0.001. The number of TRAP-positive osteoclasts at 8 weeks was significantly smaller than that at 1, 2, and 4 weeks (p < 0.001, p < 0.001, and p = 0.002, respectively, and the count at 4 weeks was smaller than that at 1 week (p = 0.011. Therefore, a regional osteoclast-related acceleratory phenomenon was maintained until 4 weeks after surgery.

  12. 3ircular dichroism simulation shows a site-II-to-site-I displacement of human serum albumin-bound diclofenac by ibuprofen

    OpenAIRE

    Yamasaki, Keishi; Rahman, Mohammed Hablbur; Tsutsumi, Yasuhiro; Maruyama, Toru; Ahmed, Shamim; Kragh-Hansen; Otagiri, Masaki

    2000-01-01

    Purpose: The purpose of this study was to confirm the hypothesis that a site-II-to-site-I displacement takes place when some nonsteroidal anti-inflammatory drugs are displaced by another drug from their high-affinity binding site to a site of lower affinity on human serum albumin (HSA).Methods: Diclofenac, sodium salt, was used as a representative example because of its prominent reversal of the Cotton effect. Effects of site-specific drugs on the free fraction of diclofenac were determined b...

  13. Rod displacement measurements by x-ray CT and its impact on thermal-hydraulics in tight-lattice rod bundle (Joint research)

    International Nuclear Information System (INIS)

    Mitsutake, Toru; Misawa, Takeharu; Kureta, Masatoshi; Akimoto, Hajime

    2005-06-01

    In tight-lattice simulated rod bundles with about 1 mm gap between rods, a rod displacement might affect thermal-hydraulic characteristics since the displacement has a strong impact on the flow area change along the heated section. It should be important to estimate how large the rod position displacement could quantitatively affect critical power for the tight-lattice rod bundle from the point of improvement of prediction capability of subchannel analysis. In the present study, the inside-structure observation of the simulated seven-rod bundle of Reduced Moderation Water Reactor (RMWR) was made through the whole length of the test assembly. Based on the measured rod position data, the relation between the rod position displacement and the heat transfer characteristics was investigated experimentally and through the two kinds of subchannel analysis, the nominal rod position case and the measured rod position case, the effect on the predicted critical power was estimated. The high-energy X-ray computer tomograph (CT) of Fuels Monitoring Facilities (FMF) at the O-arai Engineering Center in Japan Nuclear Cycle Institute (JNC) was applied for the inside-structure observation of the test assembly. The CT view of the cross sections within the test assembly assured the hexagonal rod position arrangement was almost the same as expected by design. The measured data with the X-ray CT facility showed that all rod displacements were small, 0.5 millimeters at maximum and 0.2 millimeters in average. In the heat transfer experiments for the seven-rod bundle, the boiling transition (BT) position and the rod surface temperature behavior was measured. All thermocouples on the center rod downstream from the BT-onset axial height showed almost simultaneous temperature increase due to BT. And the thermocouples located on the same axial heights showed quite similar time-variation behaviors in the vapor cooling heat transfer regime. These results demonstrated the effect of the

  14. Serous tubal intraepithelial carcinoma upregulates markers associated with high-grade serous carcinomas including Rsf-1 (HBXAP), cyclin E and fatty acid synthase.

    Science.gov (United States)

    Sehdev, Ann Smith; Kurman, Robert J; Kuhn, Elisabetta; Shih, Ie-Ming

    2010-06-01

    Serous tubal intraepithelial carcinoma (STIC) has been proposed as a precursor for many pelvic high-grade serous carcinomas. Our previous analysis of the ovarian cancer genome identified several genes with oncogenic potential that are amplified and/or overexpressed in the majority of high-grade serous carcinomas. Determining whether these genes are upregulated in STICs is important in further elucidating the relationship of STICs to high-grade serous carcinomas and is fundamental in understanding the molecular pathogenesis of high-grade serous carcinomas. In this study, 37 morphologically defined STICs were obtained from 23 patients with stage IIIC/IV high-grade serous carcinomas. Both STICs and the high-grade serous carcinomas were analyzed for expression of Rsf-1 (HBXAP), cyclin E, fatty acid synthase (FASN) and mucin-4. In addition, they were examined for expression of established markers including p53, Ki-67 and p16. We found that diffuse nuclear p53 and p16 immunoreactivity was observed in 27 (75%) of 36 and 18 (55%) of 33 STICs, respectively, whereas an elevated Ki-67 labeling index (>or=10%) was detected in 29 (78%) of 37 STICs. Cyclin E nuclear staining was seen in 24 (77%) of 35 STICs, whereas normal tubal epithelial cells were all negative. Increased Rsf-1 and FASN immunoreactivity occurred in 63%, and 62% of STICs, respectively, compared with adjacent normal-appearing tubal epithelium. Interestingly, only one STIC showed increased mucin-4 immunoreactivity. Carcinomas, when compared with STICs, overexpressed p16, Rsf-1, cyclin E and FASN in a higher proportion of cases. In conclusion, STICs express several markers including Rsf-1, cyclin E and FASN in high-grade serous carcinomas. In contrast, mucin-4 immunoreactivity either did not change or was reduced in most STICs. These results suggest that overexpression of Rsf-1, cyclin E and FASN occurs early in tumor progression.

  15. A Prospective Comparison of 18F-FDG PET/CT and CT as Diagnostic Tools to Identify the Primary Tumor Site in Patients with Extracervical Carcinoma of Unknown Primary Site

    DEFF Research Database (Denmark)

    Moller, Anne Kirstine H; Loft, Annika; Berthelsen, Anne K

    2012-01-01

    that the same set of criteria were used for classification of patients, that is, either as CUP patients or patients with a suggested primary tumor site. The independently obtained suggestions of primary tumor sites using PET/CT and CT were correlated with the SR to reach a consensus regarding true-positive (TP......), true-negative, false-negative, and false-positive results.Results. SR identified a primary tumor site in 66 CUP patients (48.9%). PET/CT identified 38 TP primary tumor sites and CT identified 43 TP primary tumor sites. No statistically significant differences were observed between (18)F-FDG PET...

  16. SU-E-J-115: Correlation of Displacement Vector Fields Calculated by Deformable Image Registration Algorithms with Motion Parameters of CT Images with Well-Defined Targets and Controlled-Motion

    Energy Technology Data Exchange (ETDEWEB)

    Jaskowiak, J; Ahmad, S; Ali, I [University of Oklahoma Health Sciences Center, Oklahoma City, OK (United States); Alsbou, N [Ohio Northern University, Ada, OH (United States)

    2015-06-15

    Purpose: To investigate correlation of displacement vector fields (DVF) calculated by deformable image registration algorithms with motion parameters in helical axial and cone-beam CT images with motion artifacts. Methods: A mobile thorax phantom with well-known targets with different sizes that were made from water-equivalent material and inserted in foam to simulate lung lesions. The thorax phantom was imaged with helical, axial and cone-beam CT. The phantom was moved with a cyclic motion with different motion amplitudes and frequencies along the superior-inferior direction. Different deformable image registration algorithms including demons, fast demons, Horn-Shunck and iterative-optical-flow from the DIRART software were used to deform CT images for the phantom with different motion patterns. The CT images of the mobile phantom were deformed to CT images of the stationary phantom. Results: The values of displacement vectors calculated by deformable image registration algorithm correlated strongly with motion amplitude where large displacement vectors were calculated for CT images with large motion amplitudes. For example, the maximal displacement vectors were nearly equal to the motion amplitudes (5mm, 10mm or 20mm) at interfaces between the mobile targets lung tissue, while the minimal displacement vectors were nearly equal to negative the motion amplitudes. The maximal and minimal displacement vectors matched with edges of the blurred targets along the Z-axis (motion-direction), while DVF’s were small in the other directions. This indicates that the blurred edges by phantom motion were shifted largely to match with the actual target edge. These shifts were nearly equal to the motion amplitude. Conclusions: The DVF from deformable-image registration algorithms correlated well with motion amplitude of well-defined mobile targets. This can be used to extract motion parameters such as amplitude. However, as motion amplitudes increased, image artifacts increased

  17. Prostate HDR brachytherapy catheter displacement between planning and treatment delivery

    International Nuclear Information System (INIS)

    Whitaker, May; Hruby, George; Lovett, Aimee; Patanjali, Nitya

    2011-01-01

    Background and purpose: HDR brachytherapy is used as a conformal boost for treating prostate cancer. Given the large doses delivered, it is critical that the volume treated matches that planned. Our outpatient protocol comprises two 9 Gy fractions, two weeks apart. We prospectively assessed catheter displacement between CT planning and treatment delivery. Materials and methods: Three fiducial markers and the catheters were implanted under transrectal ultrasound guidance. Metal marker wires were inserted into 4 reference catheters before CT; marker positions relative to each other and to the marker wires were measured from the CT scout. Measurements were repeated immediately prior to treatment delivery using pelvic X-ray with marker wires in the same reference catheters. Measurements from CT scout and film were compared. For displacements of 5 mm or more, indexer positions were adjusted prior to treatment delivery. Results: Results are based on 48 implants, in 25 patients. Median time from planning CT to treatment delivery was 254 min (range 81–367 min). Median catheter displacement was 7.5 mm (range −2.9–23.9 mm), 67% of implants had displacement of 5 mm or greater. Displacements were predominantly caudal. Conclusions: Catheter displacement can occur in the 1–3 h between the planning CT scan and treatment. It is recommended that departments performing HDR prostate brachytherapy verify catheter positions immediately prior to treatment delivery.

  18. Peroneal tendon displacement accompanying intra-articular calcaneal fractures.

    Science.gov (United States)

    Toussaint, Rull James; Lin, Darius; Ehrlichman, Lauren K; Ellington, J Kent; Strasser, Nicholas; Kwon, John Y

    2014-02-19

    Peroneal tendon displacement (subluxation or dislocation) accompanying an intra-articular calcaneal fracture is often undetected and under-treated. The goals of this study were to determine (1) the prevalence of peroneal tendon displacement accompanying intra-articular calcaneal fractures, (2) the association of tendon displacement with fracture classifications, (3) the association of tendon displacement with heel width, and (4) the rate of missed diagnosis of the tendon displacement on radiographs and computed tomography (CT) scans and the resulting treatment rate. A retrospective radiographic review of all calcaneal fractures presenting at three institutions from June 30, 2006, to June 30, 2011, was performed. CT imaging of 421 intra-articular calcaneal fractures involving the posterior facet was available for review. The prevalence of peroneal tendon displacement was noted and its associations with fracture classification and heel width were evaluated. Peroneal tendon displacement was identified in 118 (28.0%) of the 421 calcaneal fracture cases. The presence of tendon displacement was significantly associated with joint-depression fractures compared with tongue-type fractures (p displacement had been identified in the radiology reports. Although sixty-five (55.1%) of the fractures with tendon displacement had been treated with internal fixation, the tendon displacement was treated surgically in only seven (10.8%) of these cases. Analysis of CT images showed a 28% prevalence of peroneal tendon displacement accompanying intra-articular calcaneal fractures. Surgeons and radiologists are encouraged to consider this association.

  19. Apparent Dependence of Rate- and State-Dependent Friction Parameters on Loading Velocity and Cumulative Displacement Inferred from Large-Scale Biaxial Friction Experiments

    Science.gov (United States)

    Urata, Yumi; Yamashita, Futoshi; Fukuyama, Eiichi; Noda, Hiroyuki; Mizoguchi, Kazuo

    2017-06-01

    We investigated the constitutive parameters in the rate- and state-dependent friction (RSF) law by conducting numerical simulations, using the friction data from large-scale biaxial rock friction experiments for Indian metagabbro. The sliding surface area was 1.5 m long and 0.5 m wide, slid for 400 s under a normal stress of 1.33 MPa at a loading velocity of either 0.1 or 1.0 mm/s. During the experiments, many stick-slips were observed and those features were as follows. (1) The friction drop and recurrence time of the stick-slip events increased with cumulative slip displacement in an experiment before which the gouges on the surface were removed, but they became almost constant throughout an experiment conducted after several experiments without gouge removal. (2) The friction drop was larger and the recurrence time was shorter in the experiments with faster loading velocity. We applied a one-degree-of-freedom spring-slider model with mass to estimate the RSF parameters by fitting the stick-slip intervals and slip-weakening curves measured based on spring force and acceleration of the specimens. We developed an efficient algorithm for the numerical time integration, and we conducted forward modeling for evolution parameters ( b) and the state-evolution distances (L_{{c}}), keeping the direct effect parameter ( a) constant. We then identified the confident range of b and L_{{c}} values. Comparison between the results of the experiments and our simulations suggests that both b and L_{{c}} increase as the cumulative slip displacement increases, and b increases and L_{{c}} decreases as the loading velocity increases. Conventional RSF laws could not explain the large-scale friction data, and more complex state evolution laws are needed.

  20. Determination of prospective displacement-based gate threshold for respiratory-gated radiation delivery from retrospective phase-based gate threshold selected at 4D CT simulation

    International Nuclear Information System (INIS)

    Vedam, S.; Archambault, L.; Starkschall, G.; Mohan, R.; Beddar, S.

    2007-01-01

    Four-dimensional (4D) computed tomography (CT) imaging has found increasing importance in the localization of tumor and surrounding normal structures throughout the respiratory cycle. Based on such tumor motion information, it is possible to identify the appropriate phase interval for respiratory gated treatment planning and delivery. Such a gating phase interval is determined retrospectively based on tumor motion from internal tumor displacement. However, respiratory-gated treatment is delivered prospectively based on motion determined predominantly from an external monitor. Therefore, the simulation gate threshold determined from the retrospective phase interval selected for gating at 4D CT simulation may not correspond to the delivery gate threshold that is determined from the prospective external monitor displacement at treatment delivery. The purpose of the present work is to establish a relationship between the thresholds for respiratory gating determined at CT simulation and treatment delivery, respectively. One hundred fifty external respiratory motion traces, from 90 patients, with and without audio-visual biofeedback, are analyzed. Two respiratory phase intervals, 40%-60% and 30%-70%, are chosen for respiratory gating from the 4D CT-derived tumor motion trajectory. From residual tumor displacements within each such gating phase interval, a simulation gate threshold is defined based on (a) the average and (b) the maximum respiratory displacement within the phase interval. The duty cycle for prospective gated delivery is estimated from the proportion of external monitor displacement data points within both the selected phase interval and the simulation gate threshold. The delivery gate threshold is then determined iteratively to match the above determined duty cycle. The magnitude of the difference between such gate thresholds determined at simulation and treatment delivery is quantified in each case. Phantom motion tests yielded coincidence of simulation

  1. Bone quality evaluation at dental implant site using multislice CT, micro-CT, and cone beam CT.

    Science.gov (United States)

    Parsa, Azin; Ibrahim, Norliza; Hassan, Bassam; van der Stelt, Paul; Wismeijer, Daniel

    2015-01-01

    The first purpose of this study was to analyze the correlation between bone volume fraction (BV/TV) and calibrated radiographic bone density Hounsfield units (HU) in human jaws, derived from micro-CT and multislice computed tomography (MSCT), respectively. The second aim was to assess the accuracy of cone beam computed tomography (CBCT) in evaluating trabecular bone density and microstructure using MSCT and micro-CT, respectively, as reference gold standards. Twenty partially edentulous human mandibular cadavers were scanned by three types of CT modalities: MSCT (Philips, Best, the Netherlands), CBCT (3D Accuitomo 170, J Morita, Kyoto, Japan), and micro-CT (SkyScan 1173, Kontich, Belgium). Image analysis was performed using Amira (v4.1, Visage Imaging Inc., Carlsbad, CA, USA), 3Diagnosis (v5.3.1, 3diemme, Cantu, Italy), Geomagic (studio(®) 2012, Morrisville, NC, USA), and CTAn (v1.11, SkyScan). MSCT, CBCT, and micro-CT scans of each mandible were matched to select the exact region of interest (ROI). MSCT HU, micro-CT BV/TV, and CBCT gray value and bone volume fraction of each ROI were derived. Statistical analysis was performed to assess the correlations between corresponding measurement parameters. Strong correlations were observed between CBCT and MSCT density (r = 0.89) and between CBCT and micro-CT BV/TV measurements (r = 0.82). Excellent correlation was observed between MSCT HU and micro-CT BV/TV (r = 0.91). However, significant differences were found between all comparisons pairs (P micro-CT BV/TV (P = 0.147). An excellent correlation exists between bone volume fraction and bone density as assessed on micro-CT and MSCT, respectively. This suggests that bone density measurements could be used to estimate bone microstructural parameters. A strong correlation also was found between CBCT gray values and BV/TV and their gold standards, suggesting the potential of this modality in bone quality assessment at implant site. © 2013 John Wiley & Sons A/S. Published by

  2. Displacement along extensive deformation zones at the two SKB sites: Forsmark and Laxemar

    International Nuclear Information System (INIS)

    Beckholmen, Monica; Tiren, Sven A.

    2010-12-01

    The Fennoscandian shield, a part of the East European Craton, is distinguished by the exposed bedrock which is mainly composed of Precambrian metamorphic and igneous rocks. Large parts of the ground surface closely coincides with a late Precambrian denudation surface; the sub-Cambrian peneplain. Palaeozoic and younger sediments were deposited on the peneplain but these sediments have been removed from most areas that now form the mainland of Sweden and Finland and there are just a few remnants left. In the Baltic Sea, located in large-scale depressions on the boundary of in the Fennoscandian Shield/ in the East European Craton/, the Precambrian bedrock is still in large parts covered by Palaeozoic sediments. The Palaeozoic sedimentary rocks, as they are well bedded, may form a memory of the late Palaeozoic and younger tectonic events in the underlying basement rocks. Such data are used here to complement the structural observations made at sites located on the mainland, giving information on displacement along faults. Significant for the Baltic Sea are faults oriented in N-S that appear as segments, displaced relative to each other. Other structures are oriented in E-W, NE-SW and NW-SE. The SKB Forsmark site is located in a relatively flat coastal area within the sub-Cambrian peneplain. The sea area at the Forsmark site has a more accentuated relief than what is found on the mainland, for example, a furrow along the western side of the N-S oriented island Graesoe northeast of Forsmark (below 30m b.s.l. and locally more than 50m lower than Graesoe) and the deep between Aaland and Sweden (301m b.s.l.) about 100km east-southeast of Forsmark. In the Forsmark-site area two sets of structures interfere: a WNWESE trending set with relatively straight faults along the north coast of Uppland and a NNW-SSE to N-S trending set, slightly curved, along the (north)east coast of Uppland. The Forsmark site is located in an elevated WNW trending lath-shaped rock block outlined by

  3. Displacement along extensive deformation zones at the two SKB sites: Forsmark and Laxemar

    Energy Technology Data Exchange (ETDEWEB)

    Beckholmen, Monica; Tiren, Sven A. (GEOSIGMA AB (Sweden))

    2010-12-15

    The Fennoscandian shield, a part of the East European Craton, is distinguished by the exposed bedrock which is mainly composed of Precambrian metamorphic and igneous rocks. Large parts of the ground surface closely coincides with a late Precambrian denudation surface; the sub-Cambrian peneplain. Palaeozoic and younger sediments were deposited on the peneplain but these sediments have been removed from most areas that now form the mainland of Sweden and Finland and there are just a few remnants left. In the Baltic Sea, located in large-scale depressions on the boundary of in the Fennoscandian Shield/ in the East European Craton/, the Precambrian bedrock is still in large parts covered by Palaeozoic sediments. The Palaeozoic sedimentary rocks, as they are well bedded, may form a memory of the late Palaeozoic and younger tectonic events in the underlying basement rocks. Such data are used here to complement the structural observations made at sites located on the mainland, giving information on displacement along faults. Significant for the Baltic Sea are faults oriented in N-S that appear as segments, displaced relative to each other. Other structures are oriented in E-W, NE-SW and NW-SE. The SKB Forsmark site is located in a relatively flat coastal area within the sub-Cambrian peneplain. The sea area at the Forsmark site has a more accentuated relief than what is found on the mainland, for example, a furrow along the western side of the N-S oriented island Graesoe northeast of Forsmark (below 30m b.s.l. and locally more than 50m lower than Graesoe) and the deep between Aaland and Sweden (301m b.s.l.) about 100km east-southeast of Forsmark. In the Forsmark-site area two sets of structures interfere: a WNWESE trending set with relatively straight faults along the north coast of Uppland and a NNW-SSE to N-S trending set, slightly curved, along the (north)east coast of Uppland. The Forsmark site is located in an elevated WNW trending lath-shaped rock block outlined by

  4. CT findings of a displaced left upper division bronchus in adults: Its importance for performing safe left pulmonary surgery

    Energy Technology Data Exchange (ETDEWEB)

    Oshiro, Yasuji, E-mail: oshiro4211@yahoo.co.jp [Department of Radiology, National Hospital Organization Okinawa Hospital, 20-14 Ganeko 3-chome, Ginowan city, Okinawa 901-2214 (Japan); Murayama, Sadayuki [Department of Radiology, University of the Ryukus School of Medicine, 207 Uehara, Nishihara-cho, Okinawa 903-0215 (Japan); Ohta, Morio [Department of Surgery, Nakagami Hospital, 6-25-5 Chibana, Okinawa-city, Okinawa 904-2195 (Japan); Teruya, Takao [Second Department of Surgery, University of the Ryukus School of Medicine, 207 Uehara, Nishihara-cho, Okinawa 903-0215 (Japan)

    2013-08-15

    Purpose: The aim of this study was to describe the CT findings of a displaced left upper division bronchus (DLUDB) in adults. Materials and methods: Ten patients with DLUDB were identified. The following CT features were assessed: origin of the DLUDB; distance between the origin of the DLUDB and the origin of the left upper lobe (LUL) bronchus; height of the origin of the DLUDB against the left pulmonary artery (LPA); difference of the main bronchial length; ventilated segment; course of the left pulmonary artery against the DLUDB; and presence of an accessory fissure or other anomalies. Results: DLUDB arose from the posterolateral or lateral aspect of the left main bronchus immediately proximal to the origin of the LUL bronchus. It tended to course along the posterior wall of the LPA and to ventilate the apicoposterior segment with or without the anterior segment. The LPA passed between the displaced bronchus and the lingular bronchus. The origin of the DLUDB was located lower than the inferior wall of the proximal LPA in 6 patients. The accessory fissure between the associated segment and remaining part of the LUL and right tracheal bronchus coexisted in 7 and 3 patients respectively. Conclusion: DLUDB has characteristic findings on CT. Radiologists should be aware of this entity and inform the surgeon as it can prevent serious complications in a patient who may undergo lobectomy of the left lung.

  5. CT findings of a displaced left upper division bronchus in adults: Its importance for performing safe left pulmonary surgery

    International Nuclear Information System (INIS)

    Oshiro, Yasuji; Murayama, Sadayuki; Ohta, Morio; Teruya, Takao

    2013-01-01

    Purpose: The aim of this study was to describe the CT findings of a displaced left upper division bronchus (DLUDB) in adults. Materials and methods: Ten patients with DLUDB were identified. The following CT features were assessed: origin of the DLUDB; distance between the origin of the DLUDB and the origin of the left upper lobe (LUL) bronchus; height of the origin of the DLUDB against the left pulmonary artery (LPA); difference of the main bronchial length; ventilated segment; course of the left pulmonary artery against the DLUDB; and presence of an accessory fissure or other anomalies. Results: DLUDB arose from the posterolateral or lateral aspect of the left main bronchus immediately proximal to the origin of the LUL bronchus. It tended to course along the posterior wall of the LPA and to ventilate the apicoposterior segment with or without the anterior segment. The LPA passed between the displaced bronchus and the lingular bronchus. The origin of the DLUDB was located lower than the inferior wall of the proximal LPA in 6 patients. The accessory fissure between the associated segment and remaining part of the LUL and right tracheal bronchus coexisted in 7 and 3 patients respectively. Conclusion: DLUDB has characteristic findings on CT. Radiologists should be aware of this entity and inform the surgeon as it can prevent serious complications in a patient who may undergo lobectomy of the left lung

  6. Site specific measurements of bone formation using [18F] sodium fluoride PET/CT.

    Science.gov (United States)

    Blake, Glen M; Puri, Tanuj; Siddique, Musib; Frost, Michelle L; Moore, Amelia E B; Fogelman, Ignac

    2018-02-01

    Dynamic positron emission tomography (PET) imaging with fluorine-18 labelled sodium fluoride ([ 18 F]NaF) allows the quantitative assessment of regional bone formation by measuring the plasma clearance of fluoride to bone at any site in the skeleton. Today, hybrid PET and computed tomography (CT) dual-modality systems (PET/CT) are widely available, and [ 18 F]NaF PET/CT offers a convenient non-invasive method of studying bone formation at the important osteoporotic fracture sites at the hip and spine, as well as sites of pure cortical or trabecular bone. The technique complements conventional measurements of bone turnover using biochemical markers or bone biopsy as a tool to investigate new therapies for osteoporosis, and has a potential role as an early biomarker of treatment efficacy in clinical trials. This article reviews methods of acquiring and analyzing dynamic [ 18 F]NaF PET/CT scan data, and outlines a simplified approach combining venous blood sampling with a series of short (3- to 5-minute) static PET/CT scans acquired at different bed positions to estimate [ 18 F]NaF plasma clearance at multiple sites in the skeleton with just a single injection of tracer.

  7. The feasibility of surgical site tagging with CT virtual reality of the paranasal sinuses.

    Science.gov (United States)

    Hopper, K D; Iyriboz, A T; Wise, S W; Fornadley, J A

    1999-01-01

    The purpose of this work was to evaluate the feasibility of tagging (highlighting) surgical sites using volumetric CT virtual reality of the paranasal sinuses in the planning for endoscopic sinus surgery. Twenty-five patients with significant paranasal sinus disease had a planned surgical site marked on 2D coronal images. This planned surgical site was then tagged and included on CT volumetric virtual reality imaging. Each case was evaluated as to the ability of the CT virtual reality to demonstrate the planned surgical site and its orientation with respect to adjacent superficial anatomy. For all 25 planned surgeries, the virtual images showed the entire surgical site marked on the 2D coronal images. In all 25 cases, the orientation of the planned surgical site to adjacent normal anatomy was well demonstrated. For surgery into the maxillary sinuses, tagging and electronic removal of the middle turbinates and uncinate processes mimicked the actual surgery and allowed complete visualization of the infundibulum and the planned surgical site. Planned endoscopic paranasal sinus surgical sites can be easily and reliably highlighted using CT virtual reality techniques with respect to the patient's normal endoscopic anatomy.

  8. Diagnosing displaced four-part fractures of the proximal humerus

    DEFF Research Database (Denmark)

    Brorson, Stig; Bagger, Jens; Sylvest, Annette

    2009-01-01

    Displaced four-part fractures comprise 2-10 % of all proximal humeral fractures. The optimal treatment is unclear and randomised trials are needed. The conduct and interpretation of such trials is facilitated by a reproducible fracture classification. We aimed at quantifying observer agreement...... on the classification of displaced four-part fractures according to the Neer system. Published and unpublished data from five observer studies were reviewed. Observers agreed less on displaced four-part fractures than on the overall Neer classification. Mean kappa values for interobserver agreement ranged from 0.......16 to 0.48. Specialists agreed slightly more than fellows and residents. Advanced imaging modalities (CT and 3D CT) seemed to contribute more to classification of displaced four-part patterns than in less complex fracture patterns. Low observer agreement may challenge the clinical approach to displaced...

  9. The study on the X-ray correction method of long fracture displacement

    International Nuclear Information System (INIS)

    Jia Bin; Huang Ailing; Chen Fuzhong; Men Chunyan; Sui Chengzong; Cui Yiming; Yang Yundong

    2010-01-01

    Objective: To explore the image correction of fracture displacement by conventional X-ray photography (ortho tropic and lateral) and test by computed tomography (CT). Methods: The correction method of fracture displacement was designed according to geometry of X-ray photography. Selected one midhumeral fracture specimen which designed with lateral shift and angular displacement, and scanned from anteroposterior and position respectively, and also volume scanned using CT, the data obtained from volume scan were processed using multiplanar reconstruction (MPR) and shaded surface display (SSD). The displacement data relied on X-ray image, CT with MPR and SSD processing, actual design of specimens were compared respectively. Results: The direction and degree of displacement among correction data of X-ray images and the data from MPR and SSD, actual design of specimen were little difference, location difference <1.5 mm, degree difference <1.5 degree. Conclusion: It is really reliable for fracture displacement by conventional X-ray photography with coordinate correction, and it is helpful to obviously improve the diagnostic accuracy of the degree of fracture displacement. (authors)

  10. Eel calcitonin binding site distribution and antinociceptive activity in rats

    International Nuclear Information System (INIS)

    Guidobono, F.; Netti, C.; Sibilia, V.; Villa, I.; Zamboni, A.; Pecile, A.

    1986-01-01

    The distribution of binding site for [ 125 I]-eel-calcitonin (ECT) to rat central nervous system, studied by an autoradiographic technique, showed concentrations of binding in the diencephalon, the brain stem and the spinal cord. Large accumulations of grains were seen in the hypothalamus, the amygdala, in the fasciculus medialis prosencephali, in the fasciculus longitudinalis medialis, in the ventrolateral part of the periventricular gray matter, in the lemniscus medialis and in the raphe nuclei. The density of grains in the reticular formation and in the nucleus tractus spinalis nervi trigemini was more moderate. In the spinal cord, grains were scattered throughout the dorsal horns. Binding of the ligand was displaced equally by cold ECT and by salmon CT(sCT), indicating that both peptides bind to the same receptors. Human CT was much weaker than sCT in displacing [ 125 I]-ECT binding. The administration of ECT into the brain ventricles of rats dose-dependently induced a significant and long-lasting enhancement of hot-plate latencies comparable with that obtained with sCT. The antinociceptive activity induced by ECT is compatible with the topographical distribution of binding sites for the peptide and is a further indication that fish CTs are active in the mammalian brain

  11. Radiographic analysis of odontogenic cysts showing displacement of the mandibular canal

    International Nuclear Information System (INIS)

    Cho, Bong Hae

    2003-01-01

    To assess the radiographic findings of odontogenic cysts showing displacement of the mandibular canal using computed tomographic (CT) and panoramic images. CT and panoramic images of 63 odontogenic cysts (27 dentigerous, 16 odontogenic keratocysts, and 20 radicular cysts) were analyzed to evaluate the following parameters: the dimension and shape of the cysts, and the effect of the cysts on the mandibular canal and cortical plates. Of the 63 cysts examined in the study, 35 (55.6%) showed inferior displacement of the mandibular canal and 46 (73.0%) showed perforation of the canal. There were statistically significant differenced between CT and panoramic images in depicting displacement and perforation of the mandibular canal. Cortical expansion was seen in 46 cases (73.0%) and cortical perforation in 23 cases (36.5%). The radicular cysts showed cortical expansion and perforation less frequently than the other cyst groups. Large cysts of mandible should be evaluated by multiplanar CT images in order to detect the mandibular canal and cortical bone involvement.

  12. Image reconstruction design of industrial CT instrument for teaching

    International Nuclear Information System (INIS)

    Zou Yongning; Cai Yufang

    2009-01-01

    Industrial CT instrument for teaching is applied to teaching and study in field of physics and radiology major, image reconstruction is an important part of software on CT instrument. The paper expatiate on CT physical theory and first generation CT reconstruction algorithm, describe scan process of industrial CT instrument for teaching; analyze image artifact as result of displacement of rotation center, implement method of center displacement correcting, design and complete image reconstruction software, application shows that reconstructed image is very clear and qualitatively high. (authors)

  13. FDG PET/CT for therapeutic response monitoring in multi-site non-respiratory tuberculosis

    International Nuclear Information System (INIS)

    Geng Tian; Yong Xiao; Bin Chen; Jun Xia; Hong Guan; Qunyi Deng

    2010-01-01

    Background: Tuberculosis (TB) can produce positive signals during 18 F-fluorodeoxyglucose positron emission/computed tomography (FDG PET/CT) scanning. Until now, there has been no better method than clinical assessment to evaluate the therapeutic response of non-respiratory TB (NRTB). Purpose: To retrospectively assess the ability of FDG PET/CT to evaluate the response to anti-TB treatment in patients with NRTB. Material and Methods: Three patients with multi-site NRTB underwent repeat PET/CT scans during anti-TB treatment. Changes in maximal standard uptake value (SUVmax) of the TB lesions on PET/CT images were analyzed between two scans. Initial PET/CT scans were performed before the start of anti-TB treatment, and later scans were performed after completion of the treatment. Results: Patient 1, a 63-year-old female, and patient 2, a 50-year-old male, were diagnosed as multi-site NRTB by biopsy. Patient 3, a 37-year-old male was diagnosed clinically. These patients demonstrated multiple FDG-avid lesions in whole body on initial PET/CT images. The highest SUVmax of patient 1, 2, and 3 were 13.6, 17.7, and 13.9 separately. After completion of the treatment, all positive signals of patient 1, 2, and 3 decreased to undetectable value on repeated PET/CT scans with intervals of 318 days, 258 days, and 182 days separately. Conclusion: FDG PET/CT scan may be useful for monitoring responses to anti-TB treatment in patients with NRTB

  14. Sideways displacement and curved path of recti eye muscles

    NARCIS (Netherlands)

    H.J. Simonsz (Huib); F. Harting (Friedrich); B.J. de Waal (Bob); B.W.J.M. Verbeeten (Ben)

    1985-01-01

    textabstractWe investigated the sideways displacement of recti muscles with the eye in various gaze-positions by making computed tomographic (CT) scans in a plane perpendicular to the muscle cone, posterior to the globe. We found no consistent sideways displacement of the horizontal recti in the up

  15. Abdominal organ motion measured using 4D CT

    International Nuclear Information System (INIS)

    Brandner, Edward D.; Wu, Andrew; Chen, Hungcheng; Heron, Dwight; Kalnicki, Shalom; Komanduri, Krishna; Gerszten, Kristina; Burton, Steve; Ahmed, Irfan; Shou, Zhenyu

    2006-01-01

    Purpose: To measure respiration-induced abdominal organ motion using four-dimensional computed tomography (4D CT) scanning and to examine the organ paths. Methods and Materials: During 4D CT scanning, consecutive CT images are acquired of the patient at each couch position. Simultaneously, the patient's respiratory pattern is recorded using an external marker block taped to the patient's abdomen. This pattern is used to retrospectively organize the CT images into multiple three-dimensional images, each representing one breathing phase. These images are analyzed to measure organ motion between each phase. The displacement from end expiration is compared to a displacement limit that represents acceptable dosimetric results (5 mm). Results: The organs measured in 13 patients were the liver, spleen, and left and right kidneys. Their average superior to inferior absolute displacements were 1.3 cm for the liver, 1.3 cm for the spleen, 1.1 cm for the left kidney, and 1.3 cm for the right kidney. Although the organ paths varied among patients, 5 mm of superior to inferior displacement from end expiration resulted in less than 5 mm of displacement in the other directions for 41 of 43 organs measured. Conclusions: Four-dimensional CT scanning can accurately measure abdominal organ motion throughout respiration. This information may result in greater organ sparing and planning target volume coverage

  16. A low-cost landslide displacement activity assessment from time-lapse photogrammetry and rainfall data: Application to the Tessina landslide site

    Science.gov (United States)

    Gabrieli, F.; Corain, L.; Vettore, L.

    2016-09-01

    Acquiring useful and reliable displacement data from a complex landslide site is often a problem because of large, localized and scattered erosive processes and deformations; the inaccessibility of the site; the high cost of instrumentation and maintenance. However, these data are of fundamental importance not only to hazard assessments but also to understanding the processes at the basis of slope evolution. In this framework, time-lapse photogrammetry can represent a good compromise; the low accuracy is compensated for by the wide-ranging and dense spatial displacement information that can be obtained with inexpensive equipment. Nevertheless, when large displacement monitoring data sets become available, the problem becomes the choice of the most suitable statistical model to describe the probability of movement and adequately simplify the complexity of a scattered, intermittent, and spatially inhomogeneous displacement field. In this paper, an automated displacement detection method, which is based on the absolute image differences and digital correlations from a sequence of photos, was developed and applied to a photographic survey activity at the head of the Tessina landslide (northeastern Italy). The method allowed us to simplify and binarize the displacement field and to recognize the intermittent activity and the peculiar behaviours of different parts of the landslide, which were identified and classified by combining geomorphological and geological information. Moreover, for the first time, sliding correlations between these areas were quantitatively estimated using time-series-based binary logistic regression and the definition of a probability-based directed graph of displacement occurrence that connected the source zones to the lower depletion basin and the main collector channel. Using rainfall data, event-based logistic and Poisson regression models were applied to the upper zones of the landslide to estimate the probability of movement of each scarp

  17. Training improves interobserver reliability for the diagnosis of scaphoid fracture displacement.

    Science.gov (United States)

    Buijze, Geert A; Guitton, Thierry G; van Dijk, C Niek; Ring, David

    2012-07-01

    The diagnosis of displacement in scaphoid fractures is notorious for poor interobserver reliability. We tested whether training can improve interobserver reliability and sensitivity, specificity, and accuracy for the diagnosis of scaphoid fracture displacement on radiographs and CT scans. Sixty-four orthopaedic surgeons rated a set of radiographs and CT scans of 10 displaced and 10 nondisplaced scaphoid fractures for the presence of displacement, using a web-based rating application. Before rating, observers were randomized to a training group (34 observers) and a nontraining group (30 observers). The training group received an online training module before the rating session, and the nontraining group did not. Interobserver reliability for training and nontraining was assessed by Siegel's multirater kappa and the Z-test was used to test for significance. There was a small, but significant difference in the interobserver reliability for displacement ratings in favor of the training group compared with the nontraining group. Ratings of radiographs and CT scans combined resulted in moderate agreement for both groups. The average sensitivity, specificity, and accuracy of diagnosing displacement of scaphoid fractures were, respectively, 83%, 85%, and 84% for the nontraining group and 87%, 86%, and 87% for the training group. Assuming a 5% prevalence of fracture displacement, the positive predictive value was 0.23 in the nontraining group and 0.25 in the training group. The negative predictive value was 0.99 in both groups. Our results suggest training can improve interobserver reliability and sensitivity, specificity and accuracy for the diagnosis of scaphoid fracture displacement, but the improvements are slight. These findings are encouraging for future research regarding interobserver variation and how to reduce it further.

  18. [Correlation analysis between residual displacement and hip function after reconstruction of acetabular fractures].

    Science.gov (United States)

    Ma, Kunlong; Fang, Yue; Luan, Fujun; Tu, Chongqi; Yang, Tianfu

    2012-03-01

    To investigate the relationships between residual displacement of weight-bearing and non weight-bearing zones (gap displacement and step displacement) and hip function by analyzing the CT images after reconstruction of acetabular fractures. The CT measures and clinical outcome were retrospectively analyzed from 48 patients with displaced acetabular fracture between June 2004 and June 2009. All patients were treated by open reduction and internal fixation, and were followed up 24 to 72 months (mean, 36 months); all fractures healed after operation. The residual displacement involved the weight-bearing zone in 30 cases (weight-bearing group), and involved the non weight-bearing zone in 18 cases (non weight-bearing group). The clinical outcomes were evaluated by Merle d'Aubigné-Postel criteria, and the reduction of articular surface by CT images, including the maximums of two indexes (gap displacement and step displacement). All the data were analyzed in accordance with the Spearman rank correlation coefficient analysis. There was strong negative correlation between the hip function and the residual displacement values in weight-bearing group (r(s) = -0.722, P = 0.001). But there was no correlation between the hip function and the residual displacement values in non weight-bearing group (r(s) = 0.481, P = 0.059). The results of clinical follow-up were similar to the correlation analysis results. In weight-bearing group, the hip function had strong negative correlation with step displacement (r(s) = 0.825, P = 0.002), but it had no correlation with gap displacement (r(s) = 0.577, P = 0.134). In patients with acetabular fracture, the hip function has correlation not only with the extent of the residual displacement but also with the location of the residual displacement, so the residual displacement of weight-bearing zone is a key factor to affect the hip function. In patients with residual displacement in weight-bearing zone, the bigger the step displacement is, the

  19. Development of an on-site calibration method for a current transformer testing system and its application

    International Nuclear Information System (INIS)

    Jung, Jae Kap; Lee, Sang Hwa; Kwon, Sung Won; Park, Young Tae

    2008-01-01

    The ratio error and phase displacement of a current transformer (CT) are measured by using a CT testing system, which consists of a current source, a standard CT, a CT under test, a CT comparator and a CT burden. Methods for on-site calibration of the components in CT testing systems in industry have been developed recently, which do not require any component to be detached from the systems. The method utilizes several travelling transfer standards: standard CTs, non-reactive standard resistors, a calculable wide-ratio error CT and non-reactive shunt resistors. The travelling standard CT is used for absolute evaluation of a current source and a standard CT of industry. The non-reactive standard resistors and the calculable wide-ratio error CT are used to evaluate the linearity of the errors in the CT comparator. The shunt resistors are used to evaluate the CT burden of industry. The on-site calibration method using these travelling transfer standards has been successfully applied to calibration of CT testing systems in industries

  20. Training Improves Interobserver Reliability for the Diagnosis of Scaphoid Fracture Displacement

    NARCIS (Netherlands)

    Buijze, Geert A.; Guitton, Thierry G.; van Dijk, C. Niek; Ring, David; Osterman, A. Lee; Wahegaonkar, Abhijeet L.; Ladd, Amy; Barquet, Antonio; van Vugt, Arie B.; Shyam, Ashok K.; Swigart, Carrie; Coles, Chad P.; Zalavras, Charalampos; Goldfarb, Charles A.; Cassidy, Charles; Allan, Christopher; Beingessner, Daphne; Kalainov, David M.; Eygendaal, Denise; Sancheti, Parag; Feibel, Robert J.; Rocha, Steve; Grosso, Elena; Frihagen, Frede; Dyer, George S. M.; Athwal, George S.; Goslings, J. Carel; Della Rocca, Gregory J.; Harris, Ian; Fanuele, Jason C.; Lawton, Jeff; Jiuliano, John; McAuliffe, John; Capo, John T.; Conflitti, Joseph M.; Segalman, Keith; Egol, Kenneth; Ponsen, Kornelis J.; Jeray, Kyle; Lattanza, Lisa; Catalano, Louis; Swiontkowski, Marc; Boyer, Martin; Richardson, Martin; Soong, Maximillian; Baskies, Michael; Prayson, Michael; McKee, Michael; Chen, Neal C.; Kloen, Peter

    2012-01-01

    The diagnosis of displacement in scaphoid fractures is notorious for poor interobserver reliability. We tested whether training can improve interobserver reliability and sensitivity, specificity, and accuracy for the diagnosis of scaphoid fracture displacement on radiographs and CT scans. Sixty-four

  1. Effect of displaced versus non-displaced pelvic fractures on long-term racing performance in 31 Thoroughbred racehorses.

    Science.gov (United States)

    Hennessy, S E; Muurlink, M A; Anderson, G A; Puksmann, T N; Whitton, R C

    2013-06-01

    To evaluate the long-term racing prognosis for Thoroughbred racehorses with displaced versus non-displaced fractures of the pelvis identified by scintigraphy. Retrospective case analysis. Medical records of 31 Thoroughbred racehorses presenting to the University of Melbourne Equine Centre with fractures of the pelvis that were identified by scintigraphy were reviewed. Pelvic fracture site was determined and defined as displaced or non-displaced based on ultrasound and/or radiographic findings. Race records were analysed for each horse, with a minimum of 24 months' follow-up, and correlated with fracture type to determine long-term prognosis for racing. Results are expressed as median and range. Fractures at a single site were more common (n = 22) than fractures involving two sites (n = 9) and the ilial wing was the most commonly affected (n = 12). Thoroughbred racehorses with displaced pelvic fractures at any site (n = 12) raced fewer times within 24 months of diagnosis than horses with non-displaced fractures (n = 19) (median 0.5, range 0-13 vs 7, 0-24; P = 0.037), but there was no clear statistical difference in race earnings between the two groups (median A$0, range A$0-$123,250 vs A$14,440, A$0-$325,500, respectively; P = 0.080). Four horses with displaced fractures (33%) were euthanased on humane grounds because of persistent severe pain. When these horses were excluded from the analysis, there were no differences in performance variables between horses with a displaced or non-displaced pelvic fracture. Thoroughbred racehorses with a displaced or non-displaced pelvic fracture that survive the initial post-injury period have a good prognosis for racing. © 2013 The Authors. Australian Veterinary Journal © 2013 Australian Veterinary Association.

  2. Minimally Invasive Calcaneal Displacement Osteotomy Site Using a Reference Kirschner Wire: A Technique Tip.

    Science.gov (United States)

    Lee, Moses; Guyton, Gregory P; Zahoor, Talal; Schon, Lew C

    2016-01-01

    As a standard open approach, the lateral oblique incision has been widely used for calcaneal displacement osteotomy. However, just as with other orthopedic procedures that use an open approach, complications, including wound healing problems and neurovascular injury in the heel, have been reported. To help avoid these limitations, a percutaneous technique using a Shannon burr for calcaneal displacement osteotomy was introduced. However, relying on a free-hand technique without direct visualization at the osteotomy site has been a major obstacle for this technique. To address this problem, we developed a technical tip using a reference Kirschner wire. A reference Kirschner wire technique provides a reliable and accurate guide for minimally invasive calcaneal displacement osteotomy. Also, the technique should be easy to learn for surgeons new to the procedure. Copyright © 2016 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  3. Acute traumatic brain-stem hemorrhage produced by sudden caudal displacement of the brain

    International Nuclear Information System (INIS)

    Mirvis, S.E.; Wolf, A.L.; Thompson, R.K.

    1990-01-01

    This paper determines in an experimental canine study and a clinical review, whether acute caudal displacement of the brain following blunt trauma produces hemorrhage in the rostral anterior midline of the brain stem by tethering the basilar to the fixed carotid arteries. In four dogs, a balloon catheter was suddenly inflated over the frontal lobe; in two, the carotid-basilar vascular connections were severed prior to balloon inflation. ICP was monitored during and after balloon inflation. Hemorrhage was verified by MR imaging and direct inspection of the fixed brain specimens. Admission CT scans demonstrating acute traumatic brain stem hemorrhage (TBH) in human patients were reviewed to determine the site of TBH, predominant site of impact, and neurologic outcome

  4. Diagnosing displaced four-part fractures of the proximal humerus: a review of observer studies

    DEFF Research Database (Denmark)

    Brorson, Stig; Bagger, Jens; Sylvest, Annette

    2009-01-01

    Displaced four-part fractures comprise 2-10 % of all proximal humeral fractures. The optimal treatment is unclear and randomised trials are needed. The conduct and interpretation of such trials is facilitated by a reproducible fracture classification. We aimed at quantifying observer agreement...... on the classification of displaced four-part fractures according to the Neer system. Published and unpublished data from five observer studies were reviewed. Observers agreed less on displaced four-part fractures than on the overall Neer classification. Mean kappa values for interobserver agreement ranged from 0.......16 to 0.48. Specialists agreed slightly more than fellows and residents. Advanced imaging modalities (CT and 3D CT) seemed to contribute more to classification of displaced four-part patterns than in less complex fracture patterns. Low observer agreement may challenge the clinical approach to displaced...

  5. Efficacy of plain radiography and computer tomography in localizing the site of pelvic arterial bleeding in trauma patients

    Energy Technology Data Exchange (ETDEWEB)

    Dormagen, Johann B. (Dept. of Radiology, Oslo Univ. Hospital, Ullevaal, Oslo (Norway)), e-mail: johannd@medisin.uio.no; Toetterman, Anna (Dept. of Orthopedic Surgery, Uppsala Univ. Hospital, Uppsala (Sweden)); Roeise, Olav (Div. of Neuroscience and Musculoskeletal Medicine, Oslo Univ. Hospital, Ullevaal, Oslo (Norway)); Sandvik, Leiv (Center for Clinical Research, Oslo Univ. Hospital, Ullevaal, Oslo (Norway)); Kloew, Nils-E. (Dept. of Cardiovascular Radiology, Oslo Univ. Hospital - Ullevaal, Oslo (Norway))

    2010-01-15

    Background: Immediate angiography is warranted in pelvic trauma patients with suspected arterial injury (AI) in order to stop ongoing bleeding. Prior to angiography, plain pelvic radiography (PPR) and abdominopelvic computer tomography (CT) are performed to identify fracture and hematoma sites. Purpose: To investigate if PPR and CT can identify the location of AI in trauma patients undergoing angiography. Material and Methods: 95 patients with pelvic fractures on PPR (29 women, 66 men), at a mean age of 44 (9-92) years, underwent pelvic angiography for suspected AI. Fifty-six of them underwent CT additionally. Right and left anterior and posterior fractures on PPR were registered, and fracture displacement was recorded for each quadrant. Arterial blush on CT was registered, and the size of the hematoma in each region was measured in cm2. AIs were registered for anterior and posterior segments of both internal iliac arteries. Presence of fractures, arterial blush, and hematomas were correlated with AI. Results: Presence of fracture in the corresponding skeletal segment on PPR showed sensitivity and specificity of 0.86 and 0.58 posteriorly, and 0.87 and 0.44 anteriorly. The area under the curve (AUC) was 0.77 and 0.69, respectively. Fracture displacement on PPR >0.9 cm posteriorly and >1.9 cm anteriorly revealed specificity of 0.84. Sensitivities of arterial blush and hematoma on CT were 0.38 and 0.82 posteriorly, and 0.24 and 0.82 anteriorly. The specificities were 0.96 and 0.58 posteriorly, and 0.79 and 0.53 anteriorly, respectively. For hematomas, the AUC was 0.79 posteriorly and 0.75 anteriorly. Size of hematoma >22 cm2 posteriorly and >29 cm2 anteriorly revealed specificity of 0.85 and 0.86, respectively. Conclusion: CT findings of arterial blush and hematoma predicted site of arterial bleeding on pelvic angiography. Also, PPR predicted the site of bleeding using location of fracture and size of displacement. In the hemodynamically unstable patient, PPR may

  6. Efficacy of plain radiography and computer tomography in localizing the site of pelvic arterial bleeding in trauma patients.

    Science.gov (United States)

    Dormagen, Johann B; Tötterman, Anna; Røise, Olav; Sandvik, Leiv; Kløw, Nils-E

    2010-02-01

    Immediate angiography is warranted in pelvic trauma patients with suspected arterial injury (AI) in order to stop ongoing bleeding. Prior to angiography, plain pelvic radiography (PPR) and abdominopelvic computer tomography (CT) are performed to identify fracture and hematoma sites. To investigate if PPR and CT can identify the location of AI in trauma patients undergoing angiography. 95 patients with pelvic fractures on PPR (29 women, 66 men), at a mean age of 44 (9-92) years, underwent pelvic angiography for suspected AI. Fifty-six of them underwent CT additionally. Right and left anterior and posterior fractures on PPR were registered, and fracture displacement was recorded for each quadrant. Arterial blush on CT was registered, and the size of the hematoma in each region was measured in cm(2). AIs were registered for anterior and posterior segments of both internal iliac arteries. Presence of fractures, arterial blush, and hematomas were correlated with AI. Presence of fracture in the corresponding skeletal segment on PPR showed sensitivity and specificity of 0.86 and 0.58 posteriorly, and 0.87 and 0.44 anteriorly. The area under the curve (AUC) was 0.77 and 0.69, respectively. Fracture displacement on PPR >0.9 cm posteriorly and >1.9 cm anteriorly revealed specificity of 0.84. Sensitivities of arterial blush and hematoma on CT were 0.38 and 0.82 posteriorly, and 0.24 and 0.82 anteriorly. The specificities were 0.96 and 0.58 posteriorly, and 0.79 and 0.53 anteriorly, respectively. For hematomas, the AUC was 0.79 posteriorly and 0.75 anteriorly. Size of hematoma >22 cm(2) posteriorly and >29 cm(2) anteriorly revealed specificity of 0.85 and 0.86, respectively. CT findings of arterial blush and hematoma predicted site of arterial bleeding on pelvic angiography. Also, PPR predicted the site of bleeding using location of fracture and size of displacement. In the hemodynamically unstable patient, PPR may contribute equally to effective assessment of injured arteries.

  7. A framework for siting and dispatch of emerging energy resources to realize environmental and health benefits: Case study on peaker power plant displacement

    International Nuclear Information System (INIS)

    Krieger, Elena M.; Casey, Joan A.; Shonkoff, Seth B.C.

    2016-01-01

    Emerging grid resources such as energy storage and demand response have the potential to provide numerous environmental and societal benefits, but are primarily sited and operated to provide grid-specific services without optimizing these co-benefits. We present a four-metric framework to identify priority regions to deploy and dispatch these technologies to displace marginal grid air emissions with high environmental and health impacts. To the standard metrics of total mass and rate of air pollutant emissions we add location and time, to prioritize emission displacement near densely populated areas with poor air quality, especially at times when air pollutant concentrations exceed regulatory standards. We illustrate our framework with a case study using storage, demand response, and other technologies to displace peaker power plants, the highest-rate marginal emitters on the California grid. We combine spatial-temporal data on plant electricity generation, air quality standard exceedance days, and population characteristics available from environmental justice screening tool CalEnviroScreen 2.0 to determine where emissions reductions may have the greatest marginal benefit. This screening approach can inform grid siting decisions, such as storage in lieu of peaker plants in high impact regions, or dispatch protocol, such as triggering demand response instead of peaker plants on poor air quality days. - Highlights: •We develop a health and environmental framework for siting clean energy resources. •Metrics include total mass, time, rate and location of displaced marginal emissions. •Emission displacement is prioritized near dense populations on poor air quality days. •We apply our framework to the displacement of peaker power plant generation in CA. •We identify optimal places and times to site and dispatch storage and demand response.

  8. CT appearance of juvenile angiofibroma

    Energy Technology Data Exchange (ETDEWEB)

    Ueda, Jun; Hara, Kazuo (Sumitomo Hospital, Osaka (Japan)); Fukuzumi, Akio; Uchida, Hideo

    1983-06-01

    Three verified cases of juvenile angiofibroma were presented. All of them were young and adolescent male CT proved to be an ideal tool in evaluating the extension of this tumor. The appearance on plain CT was multilobulated with displacement of the adjacent bony structures. On enhancement, there was intense staining of the tumor.

  9. CT findings at the primary site of oropharyngeal squamous cell carcinoma within 6-8 weeks after definitive radiotherapy as predictors of primary site control

    International Nuclear Information System (INIS)

    Ojiri, Hiroya; Mendenhall, William M.; Mancuso, Anthony A.

    2002-01-01

    Purpose: To determine whether findings on CT studies, done 6 weeks after radiotherapy (RT), can predict the likelihood of ultimate control at the primary site in oropharyngeal carcinoma. Methods and Materials: Forty-six patients with oropharyngeal squamous cell carcinoma underwent RT with curative intent. A minimal 2-year clinical follow-up after RT was required. The primary site CT findings were graded for risk of recurrence on a modified 3-point scale as follows: Grade 0, no detectable focal abnormalities; Grade 1, anatomic asymmetry or focal mass 10 mm (2a) or 10 mm at the primary site, the likelihood of local control is high (93%). The study results indicate that CT findings, based on this relatively small series, may not add incremental information beyond that of clinical examination for predicting local control but may be useful as a baseline if imaging surveillance is contemplated

  10. Radial displacement of clinical target volume in node negative head and neck cancer

    International Nuclear Information System (INIS)

    Jeon, Wan; Wu, Hong Gyun; Song, Sang Hyuk; Kim, Jung In

    2012-01-01

    To evaluate the radial displacement of clinical target volume in the patients with node negative head and neck (H and N) cancer and to quantify the relative positional changes compared to that of normal healthy volunteers. Three node-negative H and N cancer patients and fi ve healthy volunteers were enrolled in this study. For setup accuracy, neck thermoplastic masks and laser alignment were used in each of the acquired computed tomography (CT) images. Both groups had total three sequential CT images in every two weeks. The lymph node (LN) level of the neck was delineated based on the Radiation Therapy Oncology Group (RTOG) consensus guideline by one physician. We use the second cervical vertebra body as a reference point to match each CT image set. Each of the sequential CT images and delineated neck LN levels were fused with the primary image, then maximal radial displacement was measured at 1.5 cm intervals from skull base (SB) to caudal margin of LN level V, and the volume differences at each node level were quantified. The mean radial displacements were 2.26 (±1.03) mm in the control group and 3.05 (±1.97) in the H and N cancer patients. There was a statistically significant difference between the groups in terms of the mean radial displacement (p = 0.03). In addition, the mean radial displacement increased with the distance from SB. As for the mean volume differences, there was no statistical significance between the two groups. This study suggests that a more generous radial margin should be applied to the lower part of the neck LN for better clinical target coverage and dose delivery.

  11. CT features for the detection of bowel perforation sites by blunt abdominal trauma

    International Nuclear Information System (INIS)

    Yeon, Jae Woo; Kim, Mi Young; Suh, Chang Hae; Cho, Young Up

    1996-01-01

    We evaluated the CT criteria useful for the diagnosis of the site of bowel perforation in patients with this or mesenteric injury caused by blunt abdominal trauma. CT findings of 26 patients with blunt abdominal trauma were retrospectively analyzed by two observers who were unaware of operative findings, and the results of their analysis were compared with those findings. Twenty cases of bowel perforation found at the jejunum (8), ileum (9), and colon (3), and six cases of mesenteric injuries were confirmed by operation. We evaluated CT findings of 1) segmental bowel wall thickening, b) focal mesenteric fat infiltration, c) loculated fluid collection and d) extraluminal air adjacent to the bowel, and in addition analyzed the locations of ascites and free air, and the associated injuries of solid organs. The most common finding at the site of bowel perforation was segmental bowel wall thickening (17 cases), followed by focal mesenteric fat infiltration (12 cases), loculated fluid (12 cases) and extraluminal air ajacent to the bowel (9 cases). Segmental bowel wall thickening was present at 34 sites, and the perforations were confirmed at 17 of these(50%). Focal mesenteric fat infiltration was present at 19 sites;the perforations were proven at 12(63%). Loculated fluid collections were confirmed at 12/20 sites(60%), and extraluminal air adjacent to the bowel at 9/12(75%). The positive predictive value of criteria a, b, d, c) was 100%, and the positive predictive values of a, b, c) and a, d) were 60 and 67%, respectively. We observed ascites in 16 cases and intraperitoneal free air in 8 cases, the locations of ascites and free air did not, however, significantly correlate with the perforation sites. Extraluminal air adjacent to the bowel was the most specific criterion, and segmental bowel wall thickening was the most sensitive criterion. of all criteria, the finding 'a, b, c, d' most accurately predicted the site of bowel perforation

  12. Relationships of site of impact to CT findings and outcome in diffuse brain injury

    International Nuclear Information System (INIS)

    Saito, Akihito; Kuwana, Nobumasa; Mochimatsu, Yasuhiko; Tanaka, Naoki; Fujino, Hideyo

    1985-01-01

    The relationships of the site of impact to the CT findings and to the severity and outcome of an injury were analysed based on 50 cases of diffuse brain injury (DBI). The CT findings of DBI were classified into 5 types: diffuse cerebral swelling (DCS); isodensity hemispheric swelling (IHS); deep-seated brain injury (DSI); subarachnoid hemorrhage (SAH), and normal finding (N). The sites of the impact were frontal in 19 cases, temporal in 8 cases, parietal in 4 cases, occipital in 12 cases, and multiple or undetermined in 7 cases. Frontal blows resulted in the lowest mortality rate (5.3%); on the other hand, occipital blows resulted in the highest (58%). Additionally, occipital blows caused the highest primary brain-stem injury, i.e., 41.7%. The frontal region was the most common impact area, revealing DCS and N. Temporal blows commonly resulted in DSI. Parietal blows were characteristic causes of IHS cases. However, occipital blows generally demonstrated no specific tendencies with regard to the type of CT finding. Based on this study, it is evident that CT findings and outcomes are influenced by the location of the impact. It is the authors' impression that, in severe head-injury cases, occipital blows, which are usually associated with primary brain-stem injuries, are the most serious. (author)

  13. Relationships of site of impact to CT findings and outcome in diffuse brain injury

    Energy Technology Data Exchange (ETDEWEB)

    Saito, Akihito; Kuwana, Nobumasa; Mochimatsu, Yasuhiko; Tanaka, Naoki; Fujino, Hideyo

    1985-02-01

    The relationships of the site of impact to the CT findings and to the severity and outcome of an injury were analysed based on 50 cases of diffuse brain injury (DBI). The CT findings of DBI were classified into 5 types: diffuse cerebral swelling (DCS); isodensity hemispheric swelling (IHS); deep-seated brain injury (DSI); subarachnoid hemorrhage (SAH), and normal finding (N). The sites of the impact were frontal in 19 cases, temporal in 8 cases, parietal in 4 cases, occipital in 12 cases, and multiple or undetermined in 7 cases. Frontal blows resulted in the lowest mortality rate (5.3%); on the other hand, occipital blows resulted in the highest (58%). Additionally, occipital blows caused the highest primary brain-stem injury, i.e., 41.7%. The frontal region was the most common impact area, revealing DCS and N. Temporal blows commonly resulted in DSI. Parietal blows were characteristic causes of IHS cases. However, occipital blows generally demonstrated no specific tendencies with regard to the type of CT finding. Based on this study, it is evident that CT findings and outcomes are influenced by the location of the impact. It is the authors' impression that, in severe head-injury cases, occipital blows, which are usually associated with primary brain-stem injuries, are the most serious. (author).

  14. Reducing 4D CT artifacts using optimized sorting based on anatomic similarity.

    Science.gov (United States)

    Johnston, Eric; Diehn, Maximilian; Murphy, James D; Loo, Billy W; Maxim, Peter G

    2011-05-01

    Four-dimensional (4D) computed tomography (CT) has been widely used as a tool to characterize respiratory motion in radiotherapy. The two most commonly used 4D CT algorithms sort images by the associated respiratory phase or displacement into a predefined number of bins, and are prone to image artifacts at transitions between bed positions. The purpose of this work is to demonstrate a method of reducing motion artifacts in 4D CT by incorporating anatomic similarity into phase or displacement based sorting protocols. Ten patient datasets were retrospectively sorted using both the displacement and phase based sorting algorithms. Conventional sorting methods allow selection of only the nearest-neighbor image in time or displacement within each bin. In our method, for each bed position either the displacement or the phase defines the center of a bin range about which several candidate images are selected. The two dimensional correlation coefficients between slices bordering the interface between adjacent couch positions are then calculated for all candidate pairings. Two slices have a high correlation if they are anatomically similar. Candidates from each bin are then selected to maximize the slice correlation over the entire data set using the Dijkstra's shortest path algorithm. To assess the reduction of artifacts, two thoracic radiation oncologists independently compared the resorted 4D datasets pairwise with conventionally sorted datasets, blinded to the sorting method, to choose which had the least motion artifacts. Agreement between reviewers was evaluated using the weighted kappa score. Anatomically based image selection resulted in 4D CT datasets with significantly reduced motion artifacts with both displacement (P = 0.0063) and phase sorting (P = 0.00022). There was good agreement between the two reviewers, with complete agreement 34 times and complete disagreement 6 times. Optimized sorting using anatomic similarity significantly reduces 4D CT motion

  15. Minimal displacement of novel self-anchoring catheters suitable for temporary prostate implants

    Energy Technology Data Exchange (ETDEWEB)

    Pieters, Bradley R; Grient, Johan N.B. van der; Blank, Leo E.C.M.; Koedooder, Kees; Hulshof, Maarten C.C.M.; Reijke, Theo M. de

    2006-07-15

    Catheters were developed that can be fixed in the prostate gland by self-expanding parts for use in PDR brachytherapy. Daily CT-scans were made to investigate the magnitude of catheter displacement. The mean absolute displacement during the 3 day treatment was 1.2 mm. The resulting minor alterations in dose-volume parameters were of no clinical importance.

  16. Minimal displacement of novel self-anchoring catheters suitable for temporary prostate implants

    International Nuclear Information System (INIS)

    Pieters, Bradley R.; Grient, Johan N.B. van der; Blank, Leo E.C.M.; Koedooder, Kees; Hulshof, Maarten C.C.M.; Reijke, Theo M. de

    2006-01-01

    Catheters were developed that can be fixed in the prostate gland by self-expanding parts for use in PDR brachytherapy. Daily CT-scans were made to investigate the magnitude of catheter displacement. The mean absolute displacement during the 3 day treatment was 1.2 mm. The resulting minor alterations in dose-volume parameters were of no clinical importance

  17. Inter-fractional Target Displacement in the Prostate Image-Guided Radiotherapy using Cone Beam Computed Tomography

    International Nuclear Information System (INIS)

    Dong, Kap Sang; Back, Chang Wook; Jeong, Yun Jeong; Bae, Jae Beom; Choi, Young Eun; Sung, Ki Hoon

    2016-01-01

    To quantify the inter-fractional variation in prostate displacement and their dosimetric effects for prostate cancer treatment. A total of 176 daily cone-beam CT (CBCT) sets acquired for 6 prostate cancer patients treated with volumetric-modulated arc therapy (VMAT) were retrospectively reviewed. For each patient, the planning CT (pCT) was registered to each daily CBCT by aligning the bony anatomy. The prostate, rectum, and bladder were delineated on daily CBCT, and the contours of these organs in the pCT were copied to the daily CBCT. The concordance of prostate displacement, deformation, and size variation between pCT and daily CBCT was evaluated using the Dice similarity coefficient (DSC). The mean volume of prostate was 37.2 cm3 in the initial pCT, and the variation was around ±5% during the entire course of treatment for all patients. The mean DSC was 89.9%, ranging from 70% to 100% for prostate displacement. Although the volume change of bladder and rectum per treatment fraction did not show any correlation with the value of DSC (r=-0.084, p=0.268 and r=-0.162, p=0.032, respectively), a decrease in the DSC value was observed with increasing volume change of the bladder and rectum (r=-0.230,p=0.049 and r=-0.240,p=0.020, respectively). Consistency of the volume of the bladder and rectum cannot guarantee the accuracy of the treatment. Our results suggest that patient setup with the registration between the pCT and daily CBCT should be considered aligning soft tissue

  18. Inter-fractional Target Displacement in the Prostate Image-Guided Radiotherapy using Cone Beam Computed Tomography

    Energy Technology Data Exchange (ETDEWEB)

    Dong, Kap Sang; Back, Chang Wook; Jeong, Yun Jeong; Bae, Jae Beom; Choi, Young Eun; Sung, Ki Hoon [Dept. of Radiation Oncology, Gachon University Gil Medical Center, Incheon (Korea, Republic of)

    2016-12-15

    To quantify the inter-fractional variation in prostate displacement and their dosimetric effects for prostate cancer treatment. A total of 176 daily cone-beam CT (CBCT) sets acquired for 6 prostate cancer patients treated with volumetric-modulated arc therapy (VMAT) were retrospectively reviewed. For each patient, the planning CT (pCT) was registered to each daily CBCT by aligning the bony anatomy. The prostate, rectum, and bladder were delineated on daily CBCT, and the contours of these organs in the pCT were copied to the daily CBCT. The concordance of prostate displacement, deformation, and size variation between pCT and daily CBCT was evaluated using the Dice similarity coefficient (DSC). The mean volume of prostate was 37.2 cm3 in the initial pCT, and the variation was around ±5% during the entire course of treatment for all patients. The mean DSC was 89.9%, ranging from 70% to 100% for prostate displacement. Although the volume change of bladder and rectum per treatment fraction did not show any correlation with the value of DSC (r=-0.084, p=0.268 and r=-0.162, p=0.032, respectively), a decrease in the DSC value was observed with increasing volume change of the bladder and rectum (r=-0.230,p=0.049 and r=-0.240,p=0.020, respectively). Consistency of the volume of the bladder and rectum cannot guarantee the accuracy of the treatment. Our results suggest that patient setup with the registration between the pCT and daily CBCT should be considered aligning soft tissue.

  19. Recurrent surgical site infection of the spine diagnosed by dual 18F-NaF-bone PET/CT with early-phase scan

    International Nuclear Information System (INIS)

    Shim, Jai-Joon; Lee, Jeong Won; Jeon, Min Hyok; Lee, Sang Mi

    2016-01-01

    We report a case of a 31-year-old man who showed recurrently elevated level of the serum inflammatory marker C-reactive protein (CRP) after spinal operation. He underwent 18 F-flurodeoxyglucose ( 18 F-FDG) positron emission tomography/computed tomography (PET/CT) and dual 18 F-sodium-fluoride ( 18 F-NaF) PET/CT with an additional early-phase scan to find a hidden inflammation focus. Only mildly increased 18 F-FDG was found at the surgical site of T11 spine on 18 F-FDG PET/CT. In contrast, dual 18 F-NaF bone PET/CT with early-phase scan demonstrated focal active inflammation at the surgical site of T11 spine. After a revision operation of the T11 spine, serum CRP level decreased to the normal range without any symptom or sign of inflammation. Inflammatory focus in the surgical site of the spine can be detected with using dual 18 F-NaF bone PET/CT scan with early-phase scan. (orig.)

  20. Determination of entry site for acute type A aortic dissection by initial enhanced CT-scan

    International Nuclear Information System (INIS)

    Mase, Takenori; Narumiya, Chihiro; Aoyama, Takahiko; Nagata, Yoshihisa

    2002-01-01

    Acute type A aortic dissection presents a surgical emergency because conservative therapy is not effective in the majority of instances. Enhanced CT-scan of the chest is commonly available and is considered to be an optimal diagnostic method for this disease. The operative strategy is to resect the primary tear to close the entry site of the aortic dissection and replace it with a tubular Dacron graft. Therefore, the existence of the entry site is important in determining the operative procedure. Based on the numerical value of the enhanced CT-scan inspection, the present study seeks to preoperatively identify the location of the presumed entry site in aortic dissection. From May 1996 to June 1999, 21 consecutive patients (Marfan's syndrome excluded) with acute type A aortic dissection underwent surgical treatment. Nineteen patients were preoperatively examined by enhanced CT-scan: 11 men and 8 women, with a mean age of 61 years. CT-scan slices used for early diagnosis were of the ascending aorta, aortic arch, descending aorta, and thoracoabdominal aorta. The largest diameters of the whole and true lumen were measured from cross-sectional aortic images with a personal computer, and the areas of the whole and true lumen were obtained by the manual tracing method. The true ratio was calculated for the largest diameter and area of the whole lumen. The nineteen patients were divided into two groups according to the location of the entry site based on the operating views. Seven patients with the entry site in the ascending aorta were classified as group A, and twelve patients with the entry site further in the aortic arch and descending aorta were classified as group B. Comparisons were performed by non-parametric analysis. Moreover, a discriminant analysis was applied to evaluate the classification between the two groups. The ratio of the largest diameter of the true lumen in group A at the level of the ascending and descending aorta was significantly greater than that

  1. Determination of entry site for acute type A aortic dissection by initial enhanced CT-scan

    Energy Technology Data Exchange (ETDEWEB)

    Mase, Takenori; Narumiya, Chihiro; Aoyama, Takahiko; Nagata, Yoshihisa [Aichi Medical Univ., Nagakute (Japan). School of Medicine

    2002-01-01

    Acute type A aortic dissection presents a surgical emergency because conservative therapy is not effective in the majority of instances. Enhanced CT-scan of the chest is commonly available and is considered to be an optimal diagnostic method for this disease. The operative strategy is to resect the primary tear to close the entry site of the aortic dissection and replace it with a tubular Dacron graft. Therefore, the existence of the entry site is important in determining the operative procedure. Based on the numerical value of the enhanced CT-scan inspection, the present study seeks to preoperatively identify the location of the presumed entry site in aortic dissection. From May 1996 to June 1999, 21 consecutive patients (Marfan's syndrome excluded) with acute type A aortic dissection underwent surgical treatment. Nineteen patients were preoperatively examined by enhanced CT-scan: 11 men and 8 women, with a mean age of 61 years. CT-scan slices used for early diagnosis were of the ascending aorta, aortic arch, descending aorta, and thoracoabdominal aorta. The largest diameters of the whole and true lumen were measured from cross-sectional aortic images with a personal computer, and the areas of the whole and true lumen were obtained by the manual tracing method. The true ratio was calculated for the largest diameter and area of the whole lumen. The nineteen patients were divided into two groups according to the location of the entry site based on the operating views. Seven patients with the entry site in the ascending aorta were classified as group A, and twelve patients with the entry site further in the aortic arch and descending aorta were classified as group B. Comparisons were performed by non-parametric analysis. Moreover, a discriminant analysis was applied to evaluate the classification between the two groups. The ratio of the largest diameter of the true lumen in group A at the level of the ascending and descending aorta was significantly greater than

  2. Characterization of the elastic displacement demand: Case study - Sofia city

    International Nuclear Information System (INIS)

    Paskaleva, I.; Kouteva, M.; Vaccari, F.; Panza, G.F.

    2008-02-01

    The results of the study on the seismic site response in a part of the metropolitan Sofia are discussed. The neo-deterministic seismic hazard assessment procedure has been used to compute realistic synthetic waveforms considering four earthquake scenarios, with magnitudes M = 3.7, M = 6.3 and M = 7.0. Source and site specific ground motion time histories are computed along three investigated cross sections, making use of the hybrid approach, combining the modal summation technique and the finite differences scheme. Displacement and acceleration response spectra are considered. These results are validated against the design elastic displacement response spectra and displacement demand, recommended in Eurocode 8. The elastic response design spectrum from the standard pseudo-acceleration, versus natural period, Tn, format is converted to the Sa - Sd format. The elastic displacement response spectra and displacement demand are discussed with respect to the earthquake magnitude, the seismic source-to-site distance, seismic source mechanism, and the local geological site conditions. (author)

  3. Evaluation of the tumor registration error in biopsy procedures performed under real-time PET/CT guidance.

    Science.gov (United States)

    Fanchon, Louise M; Apte, Adytia; Schmidtlein, C Ross; Yorke, Ellen; Hu, Yu-Chi; Dogan, Snjezana; Hatt, Mathieu; Visvikis, Dimitris; Humm, John L; Solomon, Stephen B; Kirov, Assen S

    2017-10-01

    The purpose of this study is to quantify tumor displacement during real-time PET/CT guided biopsy and to investigate correlations between tumor displacement and false-negative results. 19 patients who underwent real-time 18 F-FDG PET-guided biopsy and were found positive for malignancy were included in this study under IRB approval. PET/CT images were acquired for all patients within minutes prior to biopsy to visualize the FDG-avid region and plan the needle insertion. The biopsy needle was inserted and a post-insertion CT scan was acquired. The two CT scans acquired before and after needle insertion were registered using a deformable image registration (DIR) algorithm. The DIR deformation vector field (DVF) was used to calculate the mean displacement between the pre-insertion and post-insertion CT scans for a region around the tip of the biopsy needle. For 12 patients one biopsy core from each was tracked during histopathological testing to investigate correlations of the mean displacement between the two CT scans and false-negative or true-positive biopsy results. For 11 patients, two PET scans were acquired; one at the beginning of the procedure, pre-needle insertion, and an additional one with the needle in place. The pre-insertion PET scan was corrected for intraprocedural motion by applying the DVF. The corrected PET was compared with the post-needle insertion PET to validate the correction method. The mean displacement of tissue around the needle between the pre-biopsy CT and the postneedle insertion CT was 5.1 mm (min = 1.1 mm, max = 10.9 mm and SD = 3.0 mm). For mean displacements larger than 7.2 mm, the biopsy cores gave false-negative results. Correcting pre-biopsy PET using the DVF improved the PET/CT registration in 8 of 11 cases. The DVF obtained from DIR of the CT scans can be used for evaluation and correction of the error in needle placement with respect to the FDG-avid area. Misregistration between the pre-biopsy PET and the CT acquired with the

  4. Surgical Scar Site Recurrence in Patients With Cervical Cancer on 18F-FDG PET-CT: A Case-Control Study.

    Science.gov (United States)

    Dhull, Varun S; Khangembam, Bangkim C; Sharma, Punit; Rana, Neelima; Verma, Satyavrat; Sharma, Dayanand; Shamim, Shamim A; Kumar, Sunesh; Kumar, Rakesh

    2016-02-01

    The purpose of this study was to assess the role of fluorine 18 ((18)F)-fluorodeoxyglucose positron emission tomography-computed tomography ((18)F-FDG PET-CT) in evaluating various parameters in patients with surgical scar site recurrence in cervical carcinoma. Data of all patients with cervical cancer (n = 329) who underwent PET-CT at our institute between 2005 and 2013 was reviewed. Of these 329 patients, 132 patients who were surgically treated and underwent restaging/follow-up PET-CT were included in the present study for final analysis. Tumor recurrence at the abdominal surgical scar site was looked for. Abnormal uptakes suggestive of active disease at other sites were also noted. Maximum standardized uptake value was measured for all the lesions. Patients with scar site recurrence were taken as cases (n = 6), whereas the remaining patients served as controls (n = 126). Comparison with conventional imaging modalities was made wherever available. Histopathological examination was always sought for. The incidence of scar site recurrence after surgery was found to be 4.5% (6/117). A total of 56 of 132 patients had recurrent disease, including 6 patients with scar site recurrence. All of the patients with scar site recurrence also had recurrent disease at other sites (local, nodal, or distant). Conventional imaging modalities were available in 4 of these 6 patients and detected scar site recurrence in 3 of those 4 patients. In patients with scar site recurrence, the mean ± SD time to scar site recurrence was 14.0 ± 10.9 months (median, 10 months; range, 7-36 months). Significant difference was seen between cases and control for International Federation of Genecology and Oncology stage (P = 0.001) and nodal recurrence (P = 0.007). Additionally, age, nodal recurrence, distant recurrence, and scar site recurrence were significantly associated with death. Scar site recurrence carries a poor prognosis, and the incidence is much higher than previously known when PET-CT

  5. Seed displacements after permanent brachytherapy for prostate cancer in dependence on the prostate level

    International Nuclear Information System (INIS)

    Pinkawa, M.; Gagel, B.; Asadpour, B.; Piroth, M.D.; Klotz, J.; Eble, M.J.; Borchers, H.; Jakse, G.

    2008-01-01

    Purpose: to evaluate seed displacements after permanent prostate brachytherapy considering different prostate levels. Patients and methods: in 61 patients, postimplant CT scans were performed 1 day and 1 month after an implant with stranded seeds. Seed and prostate surface displacements were determined relative to pelvic bones. Four groups of seed locations were selected: seeds at the base (n = 305; B), at the apex (n = 305; A), close to the urethra (n = 306; U), and close to the rectal wall (n = 204; R). The length of two strands (always containing four seeds) per patient was measured in all CT scans and compared. Results: the largest inferior seed displacements were found at the base: mean 5.3 mm (B), 2.2 mm (A), 2.7 mm (U), 3.3 mm (R; p 3 vs. 41 cm 3 ; p < 0.001), a mean caudal prostate base displacement of 3.9 mm was found, whereas the mean inward displacement ranged from 1.2 to 1.6 mm at the remaining borders (lateral, anterior, posterior, apical). The analysis of the strand lengths revealed an implant compression between day 1 and 30 (mean 1.7 mm; p < 0.001). Conclusion: the largest prostate tissue and seed displacements were observed at the prostate base, associated with an implant compression. Predominantly inferior and posterior displacements implicate consequential smaller preplanning margins at the apex and the posterior prostate. (orig.)

  6. Epitaxial phase diagrams of SrTiO3, CaTiO3, and SrHfO3: Computational investigation including the role of antiferrodistortive and A -site displacement modes

    Science.gov (United States)

    Angsten, Thomas; Asta, Mark

    2018-04-01

    Ground-state epitaxial phase diagrams are calculated by density functional theory (DFT) for SrTiO3, CaTiO3, and SrHfO3 perovskite-based compounds, accounting for the effects of antiferrodistortive and A -site displacement modes. Biaxial strain states corresponding to epitaxial growth of (001)-oriented films are considered, with misfit strains ranging between -4 % and 4%. Ground-state structures are determined using a computational procedure in which input structures for DFT optimizations are identified as local minima in expansions of the total energy with respect to strain and soft-mode degrees of freedom. Comparison to results of previous DFT studies demonstrates the effectiveness of the computational approach in predicting ground-state phases. The calculated results show that antiferrodistortive octahedral rotations and associated A -site displacement modes act to suppress polarization and reduce the epitaxial strain energy. A projection of calculated atomic displacements in the ground-state epitaxial structures onto soft-mode eigenvectors shows that three ferroelectric and six antiferrodistortive displacement modes are dominant at all misfit strains considered, with the relative contributions from each varying systematically with the strain. Additional A -site displacement modes contribute to the atomic displacements in CaTiO3 and SrHfO3, which serve to optimize the coordination of the undersized A -site cation.

  7. Usual interstitial pneumonia and nonspecific interstitial pneumonia: Correlation between CT findings at the site of biopsy with pathological diagnoses

    Energy Technology Data Exchange (ETDEWEB)

    Sumikawa, Hiromitsu, E-mail: h-sumikawa@radiol.med.osaka-u.ac.jp [Department of Radiology, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita, Osaka 565-0825 (Japan); Johkoh, Takeshi [Department of Radiology, Kinki Central Hospital of Mutual Aid Association of Public Health Teachers, 3-1 Kurumazuka, Itami, Hyougo 664-8533 (Japan); Fujimoto, Kiminori [Department of Radiology, Kurume University School of Medicine, 67 Asahi-machi, Kurume, 830-0011 (Japan); Ichikado, Kazuya [Division of Respiratory Medicine, Saiseikai Kumamoto Hospital, 5-3-1 Tikami, Kumamoto, 861-4193 (Japan); Colby, Thomas V. [Department of Pathology, Mayo Clinic, Scottsdale, AZ (United States); Fukuoka, Junya [Laboratory of Pathology, Toyama University Hospital, Toyama (Japan); Taniguchi, Hiroyuki; Kondoh, Yasuhiro; Kataoka, Kensuke [Department of Respiratory Medicine, Tosei General Hospital, 160 Nishioiwake-cho, Seto City, Aichi (Japan); Yanagawa, Masahiro; Koyama, Mitsuhiro; Honda, Osamu; Tomiyama, Noriyuki [Department of Radiology, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita, Osaka 565-0825 (Japan)

    2012-10-15

    Objectives: The aim of this study was to correlate high-resolution CT (HRCT) findings at the site of biopsy with the whole lung CT and pathologic diagnoses in usual interstitial pneumonia (UIP) and nonspecific interstitial pneumonia (NSIP). Methods: The study included 35 patients (25 UIP and 10 NSIP) diagnosed both pathologically and clinically. 81 surgical biopsy specimens (54 UIP, and 27 NSIP) and extracted areas corresponding to biopsy sites on HRCT were analyzed. CT interpretations were compared with pathological diagnoses in both extracted images and the whole lung. Concordant and discordant cases in multiple extracted images were divided and analyzed. Then the whole cases were categorized by including or not at least one UIP diagnosis of extracted images and evaluated. Results: The diagnoses in extracted sites significantly correlated with pathological diagnoses (p = 0.047). There were significant differences in the concordances of extracted images compared with the diagnosis of whole lung and pathology (p = 0.008, 0.003, respectively). All 7 cases that were not concordant were diagnosed as radiological UIP with whole lung CT. The cases with at least one UIP diagnosis of extracted CT images were diagnosed as UIP in pathology more frequently (18 in 25) (p = 0.007). Conclusions: Radiological UIP in whole CT had more frequently discordant diagnoses from multiple extracted images than NSIP. And there were more cases in pathological UIP that included at least one UIP diagnosis of extracted images compared with pathological NSIP.

  8. CT diagnosis of annular pancreas

    International Nuclear Information System (INIS)

    Ueno, Eiko; Isobe, Yoshinori; Niimi, Akiko; Shimizu, Yasushi; Yamada, Akiyoshi; Hanyu, Fujio

    1987-01-01

    CT scan was performed in two cases of annular pancreas which could be found in one case preoperatively and in the other case retrospectively. CT scan demonstrated secondary changes of annular pancreas such as medial displacement and dilatation of the duodenal bulb in the former case and stenosis of the duodenal loop and thickened soft tissue density around the narrow segment of the duodenal loop in the latter case, although it failed to demonstrate the peninsular protrusion of the parenchyma of the pancreas head. These findings suggest high possibility of diagnosing annular pancreas by CT scan. (author)

  9. Characterization of 6-mercaptopurine binding to bovine serum albumin and its displacement from the binding sites by quercetin and rutin

    Energy Technology Data Exchange (ETDEWEB)

    Ehteshami, Mehdi [Nutrition Research Center, School of Health and Nutrition, Tabriz University of Medical Sciences, Tabriz 51644-14766 (Iran, Islamic Republic of); Rasoulzadeh, Farzaneh [Drug Applied Research Center, Tabriz University of Medical Sciences, Tabriz 51644-14766 (Iran, Islamic Republic of); Mahboob, Soltanali [Nutrition Research Center, School of Health and Nutrition, Tabriz University of Medical Sciences, Tabriz 51644-14766 (Iran, Islamic Republic of); Rashidi, Mohammad-Reza, E-mail: rashidi@tbzmed.ac.ir [Research Center for Pharmaceutical Nanotechnology, Tabriz University of Medical Sciences, Tabriz 51644-14766 (Iran, Islamic Republic of)

    2013-03-15

    Binding of a drug to the serum albumins as major serum transport proteins can be influenced by other ligands leading to alteration of its pharmacological properties. In the present study, binding characteristics of 6-mercaptopurine (6-MP) with bovine serum albumin (BSA) together with its displacement from its binding site by quercetin and rutin have been investigated by the spectroscopic method. According to the binding parameters, a static quenching component in overall dynamic quenching process is operative in the interaction between 6-MP and BSA. The binding of 6-MP to BSA occurred spontaneously due to entropy-driven hydrophobic interactions. The synchronous fluorescence spectroscopy study revealed that the secondary structure of BSA is changed in the presence of 6-MP and both Tyr and Trp residues participate in the interaction between 6-MP and BSA with the later one being more dominant. The binding constant value of 6-MP-BSA in the presence of quercetin and rutin increased. 6-MP was displaced by ibuprofen indicating that the binding site of 6-MP on albumin is site II. Therefore, the change of the pharmacokinetic and pharmacodynamic properties of 6-MP by quercetin and rutin through alteration of binding capacity of 6-MP to the serum albumin cannot be ruled out. In addition, the displacement study showed that 6-MP is located in site II of BSA. - Highlights: Black-Right-Pointing-Pointer Participation of both Tyr and particularly Trp residues in the interaction between 6-MP and BSA. Black-Right-Pointing-Pointer Involvement of a static quenching component in an overall dynamic quenching process. Black-Right-Pointing-Pointer Ability of quercetin and rutin to change the binding constants of 6-MP-BSA complex. Black-Right-Pointing-Pointer Binding of 6-MP to BSA through entropy-driven hydrophobic interactions.

  10. Study of oxide film formed in a pre cracked CT specimen of AISI 304L during a rising displacement test in 288 C water

    International Nuclear Information System (INIS)

    Diaz S, A.; Castano M, V.

    2007-01-01

    A study of oxide film formed inside pre cracked CT specimens during a rising displacement test in high temperature water (288 C) was performed in this study, The environmental conditions used during the experiments were similar to these found in Boiling Water Reactors (BWR): Normal Water Condition (NWC - 200 ppb O 2 ) and Hydrogen Water Chemistry (HWC - 125 ppb H2). The oxide films formed were analyzed by scanning electron microscopy (SEM), energy dispersive spectroscopy (EDS) and X-ray diffraction (XRD). In both cases the oxide film consisted of two layers identified as magnetite. In the case of HWC the results agree with previous reports that mention magnetite as a stable phase in reducing conditions. However the stable phase in oxidant conditions is hematite and this work shows the presence of magnetite crystals in the narrow crack of CT specimens in spite of the oxidant environmental condition. This situation confirms that inside the pre-cracked CT specimens the environmental conditions were different from the oxidant bulk, and probably a poor oxygen access and stagnant conditions within the narrow crack promoted a localized reducing environment that permitted the magnetite formation. Is evident that the crack growth studies should consider the conditions inside crack because they are significantly different. (Author)

  11. Predictors for Long-Term Hip Survivorship Following Acetabular Fracture Surgery: Importance of Gap Compared with Step Displacement.

    Science.gov (United States)

    Verbeek, Diederik O; van der List, Jelle P; Tissue, Camden M; Helfet, David L

    2018-06-06

    Historically, the greatest residual (gap or step) displacement is used to predict clinical outcome following acetabular fracture surgery. Gap and step displacement may, however, impact the outcome to different degrees. We assessed the individual relationship between gap or step displacement and hip survivorship and determined their independent association with conversion to total hip arthroplasty. Patients who had acetabular fracture fixation (from 1992 through 2014), follow-up of ≥2 years (or early conversion to total hip arthroplasty), and postoperative computed tomography (CT) scans were included. Of 227 patients, 55 (24.2%) had conversion to total hip arthroplasty at a mean follow-up (and standard deviation) of 8.7 ± 5.6 years. Residual gap and step displacement were measured using a standardized CT-based method, and assessors were blinded to the outcome. Kaplan-Meier survivorship curves for the hips were plotted and compared (log-rank test) using critical cutoff values for gap and step displacement. These values were identified using receiver operating characteristic curves. Multivariate analysis was performed to identify independent variables associated with conversion to total hip arthroplasty. Subgroup analysis was performed in younger patients (step displacement. Hip survivorship at 10 years was 82.0% for patients with a gap of step of step of ≥1.0 mm (p = 0.012). A gap of ≥5 mm (hazard ratio [HR], 2.3; p = 0.012) and an age of ≥50 years (HR, 4.2; p step of ≥1 mm (HR, 6.4; p = 0.017) was an independent factor for conversion to total hip arthroplasty. Residual gap and step displacement as measured on CT scans are both related to long-term hip survivorship, but step displacement (1 mm) is tolerated less than gap displacement (5 mm). Of the 2 types of displacement, only a large gap displacement (≥5 mm) was independently associated with conversion to total hip arthroplasty. In younger patients who had less articular impaction with smaller residual

  12. Neural network and its application to CT imaging

    Energy Technology Data Exchange (ETDEWEB)

    Nikravesh, M.; Kovscek, A.R.; Patzek, T.W. [Lawrence Berkeley National Lab., CA (United States)] [and others

    1997-02-01

    We present an integrated approach to imaging the progress of air displacement by spontaneous imbibition of oil into sandstone. We combine Computerized Tomography (CT) scanning and neural network image processing. The main aspects of our approach are (I) visualization of the distribution of oil and air saturation by CT, (II) interpretation of CT scans using neural networks, and (III) reconstruction of 3-D images of oil saturation from the CT scans with a neural network model. Excellent agreement between the actual images and the neural network predictions is found.

  13. Discovering Hominins - Application of Medical Computed Tomography (CT) to Fossil-Bearing Rocks from the Site of Malapa, South Africa.

    Science.gov (United States)

    Smilg, Jacqueline S; Berger, Lee R

    2015-01-01

    In the South African context, computed tomography (CT) has been used applied to individually prepared fossils and small rocks containing fossils, but has not been utilized on large breccia blocks as a means of discovering fossils, and particularly fossil hominins. Previous attempts at CT imaging of rocks from other South African sites for this purpose yielded disappointing results. For this study, 109 fossil- bearing rocks from the site of Malapa, South Africa were scanned with medical CT prior to manual preparation. The resultant images were assessed for accuracy of fossil identification and characterization against the standard of manual preparation. The accurate identification of fossils, including those of early hominins, that were not visible on the surface of individual blocks, is shown to be possible. The discovery of unexpected fossils is reduced, thus lowering the potential that fossils could be damaged through accidental encounter during routine preparation, or even entirely missed. This study should significantly change the way fossil discovery, recovery and preparation is done in the South African context and has potential for application in other palaeontological situations. Medical CT imaging is shown to be reliable, readily available, cost effective and accurate in finding fossils within matrix conglomerates. Improvements in CT equipment and in CT image quality are such that medical CT is now a viable imaging modality for this palaeontological application.

  14. CT findings of isthmic spondylolisthesis and degenerative spondylolisthesis

    International Nuclear Information System (INIS)

    Chang, Suk Kyeong; Cho, Seong II; Chung, Gyung Ho; Lee, Sang Yong; Han, Young Min; Sohn, Myung Hee; Kim, Chong Soo; Choi, Ki Chul

    1996-01-01

    CT evaluate the finding useful for differential diagnosis and associated abnormalities of isthmic spondylolisthesis and degenerative spondylolisthesis on CT. We reviewed retrospectively the CT images of 164 patients who were diagnosed spondylolisthesis. One hundred twelve patients had isthmic spondylolisthesis and 52 patients had degenerative spondylolisthesis. Isthmic spondylolisthesis most frequently occurred at L5. The degree of anterior displacement was grade I and II. The defect had a horizontal plane, an irregular surface, a sclerotic margin, and protruding hypertrophic bony spur in the spinal canal. The most frequently associated structural abnormality was a herniated nucleus pulposus at the upper level of the defect. Degenerative spondylolisthesis most frequently occurred at L4-5 and were grade I. The degenerative facet joint had a vertical plane, a hypertrophic bony spur, and a vacuum facet phenomenon. We frequently detected a pseudobulging disk. The most frequently associated structural abnormality was a herniated nucleus pulposus at the level of the displacement. In spondylolisthesis, the findings in CT were valuable for differential diagnosis of isthmic and degenerative types and the detection of associated symptomatic abnormalities

  15. Atomic displacements in bcc dilute alloys

    Indian Academy of Sciences (India)

    We present here a systematic investigation of the atomic displacements in bcc transition metal (TM) dilute alloys. We have calculated the atomic displacements in bcc (V, Cr, Fe, Nb, Mo, Ta and W) transition metals (TMs) due to 3d, 4d and 5d TMs at the substitutional site using the Kanzaki lattice static method. Wills and ...

  16. 18F-FDG PET/CT Findings Following Repeated Intramuscular Injections of "Site Enhancement Oil" in the Upper Extremities

    DEFF Research Database (Denmark)

    Dejanović, Danijela; Loft, Annika

    2017-01-01

    We present the findings on F-FDG PET/CT in a 50-year-old man known to self-administer intramuscular injections with site enhancement oil in the upper extremities. PET images show diffuse pathological high FDG uptake in soft tissue of the upper arms and in scanned portions of the forearms. On the CT...

  17. A study on usefulness of CT arthrography for the temporomandibular joint

    Energy Technology Data Exchange (ETDEWEB)

    Murakami, Shumei [Osaka Univ. (Japan). School of Dentistry

    1992-06-01

    In the field of orthopedics, CT arthrography has been utilized for the shoulder and the knee joints diagnosis. In this study, CT arthrography was applied to the temporomandibular joint (TMJ) and the usefulness of this method was evaluated experimentally and clinically. In the experimental study, CT, CT arthrography and arthrotomogtaphy were compared each other with serial section from human autopsy specimen. It was confirmed that arthrography was indispensable for diagnosis of the location and configuration of the articular disk. In the sagittal section, CT arthrography was almost equal to arthrotomography. But in the coronal section, CT arthrography proved to be advantageous to arthrotomography, because there were various blur images on the arthrotomographic images from the complex bony structures of the skull. In the clinical study, coronal CT arthrography was applied for the patients with internal derangements of the TMJ. The mesio-lateral displacement of the disk (62%), perforation of the attachment (23%), and the intra-articular adhesion (70%) could be diagnosed. BY CT arthrography, the mesio-lateral displacement of the disk was more clearly diagnosed and the intra-articular adhesions were proved with higher rate than by the arthrotomography. From this study, it was concluded that CT arthrography has an important role in diagnosis of the TMJ soft tissue. (author) 51 refs.

  18. Liver volume measurement: reason of the difference between in vivo CT-volumetry and intraoperative ex vivo determination and how to cope it.

    Science.gov (United States)

    Niehues, Stefan M; Unger, J K; Malinowski, M; Neymeyer, J; Hamm, B; Stockmann, M

    2010-08-20

    Volumetric assessment of the liver regularly yields discrepant results between pre- and intraoperatively determined volumes. Nevertheless, the main factor responsible for this discrepancy remains still unclear. The aim of this study was to systematically determine the difference between in vivo CT-volumetry and ex vivo volumetry in a pig animal model. Eleven pigs were studied. Liver density assessment, CT-volumetry and water displacement volumetry was performed after surgical removal of the complete liver. Known possible errors of volume determination like resection or segmentation borders were eliminated in this model. Regression analysis was performed and differences between CT-volumetry and water displacement determined. Median liver density was 1.07g/ml. Regression analysis showed a high correlation of r(2) = 0.985 between CT-volumetry and water displacement. CT-volumetry was found to be 13% higher than water displacement volumetry (pvolumetry and ex vivo water displacement volumetry seems to be blood perfusion of the liver. The systematic difference of 13 percent has to be taken in account when dealing with those measures.

  19. Branchial cleft anomalies: CT evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Seok, Eul Hye; Park, Chan Sup [College of Medicine, Inha University, Seongnam (Korea, Republic of)

    1994-04-15

    The purpose of this paper is to describe the CT findings of a variety of branchial cleft anomalies in the head and neck area. We reviewed the CT findings of 16 patients with neck lesion pathologically proved as branchial cleft anomalies. There were two first and 12 second branchial cleft cysts, one first and one second branchial cleft sinuses. Two cases of first branchial cleft cysts were manifested as thin-walled, cystic masses at auricular area. One first branchial cleft sinus was an external opening type and manifested as an ill-defined, enhancing solid lesion at posterior auricular area. All 12 cases of second branchial cleft cysts demonstrated a typical location, displacing the sternocleidomastoid muscle posteriorly, the carotid artery and internal jugular vein complex medially and the submandibular gland anteriorly. Eight cases of second branchial cleft cysts were seen as fluid-filled, round or ovoid-shaped cysts, and 3 cases of them were seen as irregular-shaped cysts. In one case, suppurative adenopathy with loss of soft tissue planes around the cyst was observed. One case of second branchial cleft sinus was manifested as a tubular-shaped, enhancing lesion at submental area and containing external opening site draining into the anterior border of the sternocleidomastoid muscle. We conclude that CT provides important diagnostic and therapeutic information in patients with a neck mass believed to be a branchial cleft anomaly, as it can differentiate various forms of the branchial anomalies by their characteristic location and shape.

  20. Branchial cleft anomalies: CT evaluation

    International Nuclear Information System (INIS)

    Seok, Eul Hye; Park, Chan Sup

    1994-01-01

    The purpose of this paper is to describe the CT findings of a variety of branchial cleft anomalies in the head and neck area. We reviewed the CT findings of 16 patients with neck lesion pathologically proved as branchial cleft anomalies. There were two first and 12 second branchial cleft cysts, one first and one second branchial cleft sinuses. Two cases of first branchial cleft cysts were manifested as thin-walled, cystic masses at auricular area. One first branchial cleft sinus was an external opening type and manifested as an ill-defined, enhancing solid lesion at posterior auricular area. All 12 cases of second branchial cleft cysts demonstrated a typical location, displacing the sternocleidomastoid muscle posteriorly, the carotid artery and internal jugular vein complex medially and the submandibular gland anteriorly. Eight cases of second branchial cleft cysts were seen as fluid-filled, round or ovoid-shaped cysts, and 3 cases of them were seen as irregular-shaped cysts. In one case, suppurative adenopathy with loss of soft tissue planes around the cyst was observed. One case of second branchial cleft sinus was manifested as a tubular-shaped, enhancing lesion at submental area and containing external opening site draining into the anterior border of the sternocleidomastoid muscle. We conclude that CT provides important diagnostic and therapeutic information in patients with a neck mass believed to be a branchial cleft anomaly, as it can differentiate various forms of the branchial anomalies by their characteristic location and shape

  1. Interactions of cephalexin with bovine serum albumin: displacement reaction and molecular docking

    Directory of Open Access Journals (Sweden)

    Hamed Hamishehkar

    2016-09-01

    Conclusion: The outcomes of spectroscopic methods revealed that the conformation of BSA changed during drug-BSA interaction. The results of FRET propose that CPL quenches the fluorescence of BSA by static quenching and FRET. The displacement study showed that phenylbutazon and ketoprofen displaced CPL, indicating that its binding site on albumin is site I and Gentamicin cannot be displaced from the binding site of CPL. All results of molecular docking method agreed with the results of experimental data.

  2. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Sinuses Computed tomography (CT) of the sinuses ... CT of the Sinuses? What is CT (Computed Tomography) of the Sinuses? Computed tomography, more commonly known ...

  3. Distal radius fracture arthroscopic intraarticular displacement measurement after open reduction and internal fixation from a volar approach.

    Science.gov (United States)

    Ono, Hiroshi; Furuta, Kazuhiko; Fujitani, Ryotaro; Katayama, Takeshi; Akahane, Manabu

    2010-07-01

    The purpose of this study was to assess articular surface reduction arthroscopically after volar locked-plate fixation of distal radius fractures (DRFs) via fluoroscopyguided open reduction/internal fixation. We also aimed to develop preoperative radiographic criteria to help assist in determining which DRFs may need arthroscopic evaluation. A total of 31 consecutive patients with DRF were prospectively enrolled. Posteroanterior (PA) and lateral radiographs as well as axial, coronal, and sagittal CT scans were obtained just after attempted reduction of the DRF. The widest articular displacement at the radiocarpal joint surface of the distal radius (preopD) was then measured using a digital radiography imaging system. The DRF was reduced under fluoroscopy, and a volar locked plate was applied. The degree of residual articular displacement was then measured arthroscopically, and the maximum displacement (postopD) was measured with a calibrated probe. Of the 31 patients, 7 had an arthroscopically assessed maximum postopD of > or = 2 mm after internal fixation. The correlation coefficients between each preopD and postopD of all radiographs and CTs were statistically significant. The cutoff values were 0.5 mm for PA radiographs, 2.10 mm for lateral radiographs, 2.15 mm for axial CT scans, 3.15 mm for coronal CT scans, and 1.20 mm for sagittal CT scans. All cutoff values for PA and lateral radiographs and for axial, coronal, and sagittal CT scans were unsuitable as screening criteria for arthroscopic reduction of DRF because of their low sensitivities and specificities. The cutoff value of the new preopD (the sum of the preopDs determined by lateral radiography and coronal CT scan) was 5.80 mm, and its sensitivity and specificity were 100% and 83.3%, respectively. Because a new preopD cutoff value of 5.80 mm is a good indicator for residual articular displacement after internal fixation of >2 mm, it is also a good indicator for the need for arthroscopic evaluation after

  4. Distal radius fracture arthroscopic intraarticular displacement measurement after open reduction and internal fixation from a volar approach

    International Nuclear Information System (INIS)

    Ono, Hiroshi; Furuta, Kazuhiko; Fujitani, Ryotaro; Katayama, Takeshi; Akahane, Manabu

    2010-01-01

    The purpose of this study was to assess articular surface reduction arthroscopically after volar locked-plate fixation of distal radius fractures (DRFs) via fluoroscopy-guided open reduction/internal fixation. We also aimed to develop preoperative radiographic criteria to help assist in determining which DRFs may need arthroscopic evaluation. A total of 31 consecutive patients with DRF were prospectively enrolled. Posteroanterior (PA) and lateral radiographs as well as axial, coronal, and sagittal CT scans were obtained just after attempted reduction of the DRF. The widest articular displacement at the radiocarpal joint surface of the distal radius (preopD) was then measured using a digital radiography imaging system. The DRF was reduced under fluoroscopy, and a volar locked plate was applied. The degree of residual articular displacement was then measured arthroscopically, and the maximum displacement (postopD) was measured with a calibrated probe. Of the 31 patients, 7 had an arthroscopically assessed maximum postopD of ≥2 mm after internal fixation. The correlation coefficients between each preopD and postopD of all radiographs and CTs were statistically significant. The cutoff values were 0.5 mm for PA radiographs, 2.10 mm for lateral radiographs, 2.15 mm for axial CT scans, 3.15 mm for coronal CT scans, and 1.20 mm for sagittal CT scans. All cutoff values for PA and lateral radiographs and for axial, coronal, and sagittal CT scans were unsuitable as screening criteria for arthroscopic reduction of DRF because of their low sensitivities and specificities. The cutoff value of the new preopD (the sum of the preopDs determined by lateral radiography and coronal CT scan) was 5.80 mm, and its sensitivity and specificity were 100% and 83.3%, respectively. Because a new preopD cutoff value of 5.80 mm is a good indicator for residual articular displacement after internal fixation of >2 mm, it is also a good indicator for the need for arthroscopic evaluation after

  5. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Head Computed tomography (CT) of the head uses special x-ray ... What is CT Scanning of the Head? Computed tomography, more commonly known as a CT or CAT ...

  6. SU-E-J-222: Evaluation of Deformable Registration of PET/CT Images for Cervical Cancer Brachytherapy

    International Nuclear Information System (INIS)

    Liao, Y; Turian, J; Templeton, A; Kiel, K; Chu, J; Kadir, T

    2014-01-01

    Purpose: PET/CT provides important functional information for radiotherapy targeting of cervical cancer. However, repeated PET/CT procedures for external beam and subsequent brachytherapy expose patients to additional radiation and are not cost effective. Our goal is to investigate the possibility of propagating PET-active volumes for brachytherapy procedures through deformable image registration (DIR) of earlier PET/CT and ultimately to minimize the number of PET/CT image sessions required. Methods: Nine cervical cancer patients each received their brachytherapy preplanning PET/CT at the end of EBRT with a Syed template in place. The planning PET/CT was acquired on the day of brachytherapy treatment with the actual applicator (Syed or Tandem and Ring) and rigidly registered. The PET/CT images were then deformably registered creating a third (deformed) image set for target prediction. Regions of interest with standardized uptake values (SUV) greater than 65% of maximum SUV were contoured as target volumes in all three sets of PET images. The predictive value of the registered images was evaluated by comparing the preplanning and deformed PET volumes with the planning PET volume using Dice's coefficient (DC) and center-of-mass (COM) displacement. Results: The average DCs were 0.12±0.14 and 0.19±0.16 for rigid and deformable predicted target volumes, respectively. The average COM displacements were 1.9±0.9 cm and 1.7±0.7 cm for rigid and deformable registration, respectively. The DCs were improved by deformable registration, however, both were lower than published data for DIR in other modalities and clinical sites. Anatomical changes caused by different brachytherapy applicators could have posed a challenge to the DIR algorithm. The physiological change from interstitial needle placement may also contribute to lower DC. Conclusion: The clinical use of DIR in PET/CT for cervical cancer brachytherapy appears to be limited by applicator choice and requires further

  7. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Abdomen and Pelvis Computed tomography (CT) of the abdomen and pelvis is a ... is CT Scanning of the Abdomen/Pelvis? Computed tomography, more commonly known as a CT or CAT ...

  8. A correlation study on the displacement of the whole breast target after breast-conserving surgery based on four-dimensional computed tomography

    International Nuclear Information System (INIS)

    Wang Wei; Li Jianbin; Wang Suzhen; Zhang Yingjie; Li Fengxiang; Xu Min; Shang Dongping

    2011-01-01

    Objective: To investigate the correlations of the whole breast displacement in different respiratory cycle during free breathing (FB) following breast-conserving surgery to the displacement of selected skin marker, nipple, and selected surgical clip based on four-dimensional computed tomography (4D-CT). Methods: Thirteen breast cancer patients who had undergone breast-conserving surgery received whole breast intensity-modulated radiotherapy (IMRT). Respiration-synchronized 4D-CT image data were gathered during FB and were exported to the Varian Eclipse treatment planning system, and the whole breast target, nipple, superior clip,and metal marker on the skin at the anterior body midline were delineated on the CT images of ten phases of the respiratory cycle by the same radiotherapist based on the same delineating criteria. The displacement distances of the delineated target in the mediolateral (x), anteroposterior (y), and superoinferior (z) axles were achieved,and the correlations of the whole breast target displacement to the displacement of the clip, nipple, and skin marker were analyzed. The ipsilateral lung was delineated on the CT images of every phase of the respiratory cycle, and the changes in ipsilateral lung volume were analyzed during the respiratory cycle relative to the displacement of the breast. Results: The maximal displacement distances of the whole breast target in the x, y, and z axles during FB were 0.71, 0.76 and 1.29 mm, respectively (F=5.755, P<0.05). There was no relationship between the three-dimensional (3D) displacement of the whole breast and the volume of the whole breast (r=-0.264, P<0.05), and there was no relationship between the displacement of the whole breast and the volume change of the ipsilateral lung (r=0.346, P<0.05). There was no significant difference among the mean target displacement distances in 3 axles,and among 2 selected successive end-inspiration (EI) phases and 3 selected successive end-expiration (EE) phases. There

  9. Liver volume measurement: reason of the difference between in vivo CT-volumetry and intraoperative ex vivo determination and how to cope it

    Directory of Open Access Journals (Sweden)

    Niehues SM

    2010-08-01

    Full Text Available Abstract Purpose Volumetric assessment of the liver regularly yields discrepant results between pre- and intraoperatively determined volumes. Nevertheless, the main factor responsible for this discrepancy remains still unclear. The aim of this study was to systematically determine the difference between in vivo CT-volumetry and ex vivo volumetry in a pig animal model. Material and Methods Eleven pigs were studied. Liver density assessment, CT-volumetry and water displacement volumetry was performed after surgical removal of the complete liver. Known possible errors of volume determination like resection or segmentation borders were eliminated in this model. Regression analysis was performed and differences between CT-volumetry and water displacement determined. Results Median liver density was 1.07 g/ml. Regression analysis showed a high correlation of r2 = 0.985 between CT-volumetry and water displacement. CTvolumetry was found to be 13% higher than water displacement volumetry (p Conclusion In this study the only relevant factor leading to the difference between in vivo CT-volumetry and ex vivo water displacement volumetry seems to be blood perfusion of the liver. The systematic difference of 13 percent has to be taken in account when dealing with those measures.

  10. Four-dimensional measurement of the displacement of internal fiducial and skin markers during 320-multislice computed tomography scanning of breast cancer.

    Science.gov (United States)

    Yamashita, Hideomi; Okuma, Kae; Tada, Keiichiro; Shiraishi, Kenshiro; Takahashi, Wataru; Shibata-Mobayashi, Shino; Sakumi, Akira; Saotome, Naoya; Haga, Akihiro; Onoe, Tsuyoshi; Ino, Kenji; Akahane, Masaaki; Ohtomo, Kuni; Nakagawa, Keiichi

    2012-10-01

    To study the three-dimensional movement of internal tumor bed fiducial and breast skin markers, using 320-multislice computed tomography (CT); and to analyze intrafractional errors for breast cancer patients undergoing breast irradiation. This study examined 280 markers on the skin of the breast (200 markers) and on the primary tumor bed (80 markers) of 20 patients treated by external-beam photon radiotherapy. Motion assessment was analyzed in 41 respiratory phases during 20 s of cine CT in the radiotherapy position. To assess intrafractional errors resulting from respiratory motion, four-dimensional CT scans were acquired for 20 patients. Motion in the anterior-posterior (A/P) and superior-inferior (S/I) directions showed a strong correlation (|r| > 0.7) with the respiratory curve for most markers (79% and 70%, respectively). The average marker displacements between maximum and minimum value during 20 s for the 200 breast skin metal markers were 1.1 ± 0.3 mm, 2.1 ± 0.6 mm, and 1.6 ± 0.4 mm in the left-right, A/P, and S/I directions, respectively. For the 80 tumor bed clips, displacements were 0.9 ± 0.2 mm in left-right, 1.7 ± 0.5 mm in A/P, and 1.1 ± 0.3 mm in S/I. There was no significant difference in the motion between breast quadrant regions or between the primary site and the other regions. Motion in primary breast tumors was evaluated with 320-multislice CT. Very little change was detected during individual radiation treatment fractions. Copyright © 2012 Elsevier Inc. All rights reserved.

  11. Irreducible Anterior Shoulder Dislocation Associated With Displaced Fracture of the Greater Tuberosity: An Analysis of Seven Cases

    Directory of Open Access Journals (Sweden)

    Morteza Nakhaei Amroodi

    2015-11-01

    Full Text Available Background: Although anterior shoulder dislocation is the most prevalent type of body dislocation, irreducible anterior shoulder dislocation is seldom reported in the literature, which is usually due to physical obstacles. Objectives: This study presents our findings regarding the causes of irreducibility of anterior shoulder dislocation associated with displaced fracture of the greater tuberosity. Patients and Methods: CT scans, open reduction of the joint, and internal fixation of the tuberosity was performed in seven patients with irreducible anterior shoulder dislocation associated with displaced fracture of the greater tuberosity. Results: As confirmed by intraoperative findings, the CT scans showed the cause of irreducible shoulder dislocation in six cases was the interposition of the long head of biceps (LHB in the anterior of the head that was displaced from the fracture line between the greater and lesser tuberosities. In another case, the greater and lesser tuberosities were attached to each other and were separated from the head. This fractured part was trapped. Conclusions: We suggest that performing CT scans in all cases of anterior shoulder dislocations with displaced fracture of the greater tuberosity can help surgeons to diagnose the accompanying fractures and possible complications, such as irreducibility. If the fracture line passes through the bicipital groove or in the case of a shield fracture, possible irreducibility should be borne in mind.

  12. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... Site Index A-Z Children's (Pediatric) CT (Computed Tomography) Pediatric computed tomography (CT) is a fast, painless exam that uses ... of Children's CT? What is Children's CT? Computed tomography, more commonly known as a CT or CAT ...

  13. Seed displacements after permanent brachytherapy for prostate cancer in dependence on the prostate level

    Energy Technology Data Exchange (ETDEWEB)

    Pinkawa, M.; Gagel, B.; Asadpour, B.; Piroth, M.D.; Klotz, J.; Eble, M.J. [Dept. of Radiotherapy, RWTH Aachen (Germany); Borchers, H.; Jakse, G. [Dept. of Urology, RWTH Aachen (Germany)

    2008-10-15

    Purpose: to evaluate seed displacements after permanent prostate brachytherapy considering different prostate levels. Patients and methods: in 61 patients, postimplant CT scans were performed 1 day and 1 month after an implant with stranded seeds. Seed and prostate surface displacements were determined relative to pelvic bones. Four groups of seed locations were selected: seeds at the base (n = 305; B), at the apex (n = 305; A), close to the urethra (n = 306; U), and close to the rectal wall (n = 204; R). The length of two strands (always containing four seeds) per patient was measured in all CT scans and compared. Results: the largest inferior seed displacements were found at the base: mean 5.3 mm (B), 2.2 mm (A), 2.7 mm (U), 3.3 mm (R; p < 0.001). Posterior displacements predominated both at the base and the central region: mean 2.2 mm (B), 2.0 mm (U), 0.8 mm (A), -0.6 mm (R; p < 0.001). With a decreasing edema between day 1 and 30 (mean prostate volume of 51 cm{sup 3} vs. 41 cm{sup 3}; p < 0.001), a mean caudal prostate base displacement of 3.9 mm was found, whereas the mean inward displacement ranged from 1.2 to 1.6 mm at the remaining borders (lateral, anterior, posterior, apical). The analysis of the strand lengths revealed an implant compression between day 1 and 30 (mean 1.7 mm; p < 0.001). Conclusion: the largest prostate tissue and seed displacements were observed at the prostate base, associated with an implant compression. Predominantly inferior and posterior displacements implicate consequential smaller preplanning margins at the apex and the posterior prostate. (orig.)

  14. Predicting the holistic force-displacement relation of the periodontal ligament: in-vitro experiments and finite element analysis

    OpenAIRE

    Chang, Chih-Han; Lei, Yao-Ning; Ho, Yi-Hung; Sung, Yu-Hsing; Lin, Ting-Sheng

    2014-01-01

    Background The biomechanical property of the periodontal ligament (PDL) is important in orthodontics and prosthodontics. The objective of this study was to evaluate the feasibility of measuring the biomechanical behavior of the periodontal ligament using micro-computed tomography (micro-CT). Methods A custom-made apparatus measured the force and displacement of a porcine PDL specimen within the micro-CT environment. Synchronized computed tomography (CT) images were used to obtain the deformat...

  15. CT and MRI diagnosis of nasopharyneal angiofibroma

    International Nuclear Information System (INIS)

    Zhang Xiaoya; Liang Biling

    2007-01-01

    Objective: To analyze the CT and MRI manifestations of nasopharyneal angiofibroma. Methods: 21 cases of nasopharyneal angiofibroma are retrospectively analyzed according to the location, size, margin, density or signal of the tumor and the changes of surrounding bones. Results: The CT and MRI showed a nasopharyneal mass with well-defined margin, uniform density or signal and remarkably enhanced. The sphenomaxillary fossa was enlarged and the posterior wall of maxillary sinus was, compressed and displaced without bone destruction. The surrounding bone appeared to be compressed, molded, absorbed or destroyed. Conclusion: CT examination can usually provide diagnostic information, but the combination of CT and MRI can be better contributed to the diagnosis, location and stage classification of nasopharyneal angiofbroma. (authors)

  16. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z Children's (Pediatric) CT (Computed Tomography) Pediatric computed tomography (CT) ... are the limitations of Children's CT? What is Children's CT? Computed tomography, more commonly known as a ...

  17. CT study in primary low spinal fluid pressure syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Hoshino, Moritoshi; Okayama, Kenji; Kubo, Hiromasa; Watanabe, Hiromi; Endou, Riuko (Ohmiya Red Cross Hospital, Yono, Saitama (Japan))

    1991-02-01

    CT findings in primary low spinal fluid pressure syndrome were studied on the basis of 3 cases. Case 1 was a 43-year-old male with a complicated bilateral isodense subdural hematoma (SDH). Case 2 was a 45-year-old female with a complicated bilateral high dense SDH. Case 3 was a 36-year-old female discharged without any complications after spinal fluid pressure normalized. Slight downward displacement of the brain under low spinal fluid pressure was shown as the narrowing of a Sylvian fissures and infratentorial cisterns on CT. On the other hand, in this syndrome with a complicated bilateral isodense SDH, in addition to this finding, CT revealed distortion and narrowing of body lateral ventricles, which might be differential findings from this syndrome without complicated SDH. Under low spinal fluid pressure, bridging veins are more stretched by a downward displacement of the brain. And consequently they were easily injured and SDH was developed. (author).

  18. CT Perfusion Characteristics Identify Metastatic Sites in Liver

    Directory of Open Access Journals (Sweden)

    Yuan Wang

    2015-01-01

    Full Text Available Tissue perfusion plays a critical role in oncology because growth and migration of cancerous cells require proliferation of new blood vessels through the process of tumor angiogenesis. Computed tomography (CT perfusion is an emerging functional imaging modality that measures tissue perfusion through dynamic CT scanning following intravenous administration of contrast medium. This noninvasive technique provides a quantitative basis for assessing tumor angiogenesis. CT perfusion has been utilized on a variety of organs including lung, prostate, liver, and brain, with promising results in cancer diagnosis, disease prognostication, prediction, and treatment monitoring. In this paper, we focus on assessing the extent to which CT perfusion characteristics can be used to discriminate liver metastases from neuroendocrine tumors from normal liver tissues. The neuroendocrine liver metastases were analyzed by distributed parameter modeling to yield tissue blood flow (BF, blood volume (BV, mean transit time (MTT, permeability (PS, and hepatic arterial fraction (HAF, for tumor and normal liver. The result reveals the potential of CT perfusion as a tool for constructing biomarkers from features of the hepatic vasculature for guiding cancer detection, prognostication, and treatment selection.

  19. Blunt pancreatic trauma. Role of CT

    International Nuclear Information System (INIS)

    Procacci, C.; Graziani, R.; Bicego, E.; Mainardi, P.; Bassi, C.; Bergamo Andreis, I.A.; Valdo, M.; Guarise, A.; Girelli, M.

    1997-01-01

    Purpose: To define the evolution patterns of blunt pancreatic trauma, and to point out the CT features most significant for the diagnosis. Material and Methods: Ten cases of pancreatic trauma, observed over a period of about 10 years, were analyzed in retrospect. The cases were divided into 3 groups according to the time that had elapsed between trauma and first CT: Early phase (within 72 h: n=3/10); late phase (after 10 days: n=3/10); and following pancreatic drainage (n=4/10). Results: In the early phase, one case showed a blood collection surrounding the pancreatic head and duodenum, and displacing the mesenteric vessels to the left. In the 2 other cases it was possible to demonstrate a tear in the pancreas at the neck, perpendicular to the main pancreatic axis. In the late phase in all 3 cases, one cystic lesion was present at the site of the tear, either surrounding the gland or embedded - more or less deeply - within the parenchyma. One of the lesions subsided spontaneously; the 2 others required surgery. In the postoperative phase, an external fistula was demonstrated in 2 cases following percutaneous drainage of pancreatic cysts; the fistula was fed by a cystic lesion in the pancreatic neck. In the 2 other cases a pseudocyst developed. (orig.)

  20. Blunt pancreatic trauma. Role of CT

    Energy Technology Data Exchange (ETDEWEB)

    Procacci, C. [Dept. of Radiology, Univ. Hospital, Verona (Italy); Graziani, R. [Dept. of Radiology, Univ. Hospital, Verona (Italy); Bicego, E. [Dept. of Radiology, Univ. Hospital, Verona (Italy); Mainardi, P. [Dept. of Radiology, Univ. Hospital, Verona (Italy); Bassi, C. [Dept. of Surgery, Univ. Hospital, Verona (Italy); Bergamo Andreis, I.A. [Dept. of Radiology, Univ. Hospital, Verona (Italy); Valdo, M. [Dept. of Radiology, Univ. Hospital, Verona (Italy); Guarise, A. [Dept. of Radiology, Univ. Hospital, Verona (Italy); Girelli, M. [Dept. of Radiology, Univ. Hospital, Verona (Italy)

    1997-07-01

    Purpose: To define the evolution patterns of blunt pancreatic trauma, and to point out the CT features most significant for the diagnosis. Material and Methods: Ten cases of pancreatic trauma, observed over a period of about 10 years, were analyzed in retrospect. The cases were divided into 3 groups according to the time that had elapsed between trauma and first CT: Early phase (within 72 h: n=3/10); late phase (after 10 days: n=3/10); and following pancreatic drainage (n=4/10). Results: In the early phase, one case showed a blood collection surrounding the pancreatic head and duodenum, and displacing the mesenteric vessels to the left. In the 2 other cases it was possible to demonstrate a tear in the pancreas at the neck, perpendicular to the main pancreatic axis. In the late phase in all 3 cases, one cystic lesion was present at the site of the tear, either surrounding the gland or embedded - more or less deeply - within the parenchyma. One of the lesions subsided spontaneously; the 2 others required surgery. In the postoperative phase, an external fistula was demonstrated in 2 cases following percutaneous drainage of pancreatic cysts; the fistula was fed by a cystic lesion in the pancreatic neck. In the 2 other cases a pseudocyst developed. (orig.).

  1. Measurement of lung tumor motion using respiration-correlated CT

    International Nuclear Information System (INIS)

    Mageras, Gig S.; Pevsner, Alex; Yorke, Ellen D.; Rosenzweig, Kenneth E.; Ford, Eric C.; Hertanto, Agung; Larson, Steven M.; Lovelock, D. Michael; Erdi, Yusuf E.; Nehmeh, Sadek A.; Humm, John L.; Ling, C. Clifton

    2004-01-01

    Purpose: We investigate the characteristics of lung tumor motion measured with respiration-correlated computed tomography (RCCT) and examine the method's applicability to radiotherapy planning and treatment. Methods and materials: Six patients treated for non-small-cell lung carcinoma received a helical single-slice computed tomography (CT) scan with a slow couch movement (1 mm/s), while simultaneously respiration is recorded with an external position-sensitive monitor. Another 6 patients receive a 4-slice CT scan in a cine mode, in which sequential images are acquired for a complete respiratory cycle at each couch position while respiration is recorded. The images are retrospectively resorted into different respiration phases as measured with the external monitor (4-slice data) or patient surface displacement observed in the images (single-slice data). The gross tumor volume (GTV) in lung is delineated at one phase and serves as a visual guide for delineation at other phases. Interfractional GTV variation is estimated by scaling diaphragm position variations measured in gated radiographs at treatment with the ratio of GTV:diaphragm displacement observed in the RCCT data. Results: Seven out of 12 patients show GTV displacement with respiration of more than 1 cm, primarily in the superior-inferior (SI) direction; 2 patients show anterior-posterior displacement of more than 1 cm. In all cases, extremes in GTV position in the SI direction are consistent with externally measured extremes in respiration. Three patients show evidence of hysteresis in GTV motion, in which the tumor trajectory is displaced 0.2 to 0.5 cm anteriorly during expiration relative to inspiration. Significant (>1 cm) expansion of the GTV in the SI direction with respiration is observed in 1 patient. Estimated intrafractional GTV motion for gated treatment at end expiration is 0.6 cm or less in all cases; however; interfraction variation estimates (systematic plus random) are more than 1 cm in 3

  2. Standard test method for crack-tip opening displacement (CTOD) fracture toughness measurement

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 This test method covers the determination of critical crack-tip opening displacement (CTOD) values at one or more of several crack extension events, and may be used to measure cleavage crack initiation toughness for materials that exhibit a change from ductile to brittle behavior with decreasing temperature, such as ferritic steels. This test method applies specifically to notched specimens sharpened by fatigue cracking. The recommended specimens are three-point bend [SE(B)], compact [C(T)], or arc-shaped bend [A(B)] specimens. The loading rate is slow and influences of environment (other than temperature) are not covered. The specimens are tested under crosshead or clip gage displacement controlled loading. 1.1.1 The recommended specimen thickness, B, for the SE(B) and C(T) specimens is that of the material in thicknesses intended for an application. For the A(B) specimen, the recommended depth, W, is the wall thickness of the tube or pipe from which the specimen is obtained. Superficial surface machini...

  3. CT of the temporomandibular joint: The conservative approach

    International Nuclear Information System (INIS)

    Jend, H.H.; Jend-Rossmann, I.; Heller, M.

    1986-01-01

    Until recently, CT investigation of temporomandibular joint (TMJ) disorders has been regarded as a sophisticated procedure. A method of investigation was developed that allows easy evaluation of axial scans. The method was evaluated in a series of 65 joints with arthrographically diagnosed internal derangements. In anterior disk displacement CT findings led to an identical diagnosis in 56 of 65 joints (sensitivity, 86%). In clinically asymptomatic joints investigated for other reasons, only one of 12 showed signs of internal derangement on CT (specificity, 92%). This conservative approach to CT evaluation of internal derangement seems to be as accurate as more sophisticated methods. It is easy to perform, requires no additional manpower or computer time, and has a very good reproducibility

  4. Bone bruise, lipohemarthrosis, and joint effusion in CT of non-displaced hip fracture

    International Nuclear Information System (INIS)

    Geijer, Mats; Dunker, Dennis; Collin, David; Goethlin, Jan H.

    2012-01-01

    Background. A suspected occult hip fracture after normal radiography is not uncommon in an elderly person after a fall. Despite a lack of robust validation in the literature, computed tomography (CT) is often used as secondary imaging. Purpose. To assess the frequency and clinical utility of non-cortical skeletal and soft tissue lesions as ancillary fracture signs in CT diagnosis of occult hip fractures. Material and Methods. All fracture signs (cortical and trabecular fractures, bone bruise, joint effusion, and lipohemarthrosis) were recorded in 231 hip low-energy trauma cases with CT performed after normal or equivocal radiography in two trauma centers. Results. There were no fracture signs in 110 patients. Twelve of these had a joint effusion. In 121 patients with 46 cervical hip fractures and 75 trochanteric fractures one or more fracture signs were present. Cortical fractures were found in 115 patients. Bone bruise was found in 119 patients, joint effusion in 35, and lipohemarthrosis in 20 patients. Conclusion. Ancillary signs such as bone bruise and lipohemarthrosis can strengthen and sometimes indicate the diagnosis in CT of occult hip fractures. Joint effusion is a non-specific sign

  5. Bone bruise, lipohemarthrosis, and joint effusion in CT of non-displaced hip fracture

    Energy Technology Data Exchange (ETDEWEB)

    Geijer, Mats (Center for Medical Imaging and Physiology, Skaane University Hospital, Lund University, Lund (Sweden)), Email: mats@geijer.info; Dunker, Dennis; Collin, David; Goethlin, Jan H. (Department of Radiology, Sahlgrenska University Hospital, Moelndal (Sweden))

    2012-03-15

    Background. A suspected occult hip fracture after normal radiography is not uncommon in an elderly person after a fall. Despite a lack of robust validation in the literature, computed tomography (CT) is often used as secondary imaging. Purpose. To assess the frequency and clinical utility of non-cortical skeletal and soft tissue lesions as ancillary fracture signs in CT diagnosis of occult hip fractures. Material and Methods. All fracture signs (cortical and trabecular fractures, bone bruise, joint effusion, and lipohemarthrosis) were recorded in 231 hip low-energy trauma cases with CT performed after normal or equivocal radiography in two trauma centers. Results. There were no fracture signs in 110 patients. Twelve of these had a joint effusion. In 121 patients with 46 cervical hip fractures and 75 trochanteric fractures one or more fracture signs were present. Cortical fractures were found in 115 patients. Bone bruise was found in 119 patients, joint effusion in 35, and lipohemarthrosis in 20 patients. Conclusion. Ancillary signs such as bone bruise and lipohemarthrosis can strengthen and sometimes indicate the diagnosis in CT of occult hip fractures. Joint effusion is a non-specific sign

  6. Displacement functions for diatomic materials

    International Nuclear Information System (INIS)

    Panrkin, D.M.; Coulter, C.A.

    1979-01-01

    An extension of the methods of Lindhard et at. was used to calculate the total displacement function n/sub ij/(E) for a number of diatomic materials, where n/sub ij/(E) is defined to be the average number of atoms of type j which are displaced from their sites in a displacement cascade initiated by a PKA of type i and energy E. From the n/sub ij/(E) one can calculate the fraction n/sub ij/(E) of the displacements produced by a type i PKA with energy E which are of type j. Values of the n/sub ij/ for MgO, CaO, Al 2 O 3 , and TaO are presented. It is shown that for diatomic materials with mass ratios reasonably near one (e.g., MgO, Al 2 O 3 ) and equal displacement thresholds for the two species the n/sub ij/ become independent of the PKA type i at energies only a few times threshold. However, for larger mass ratios the n/sub ij/ do not become independent of i until much larger, energies are reached - e.g. > 10 5 eV for TaO. In addition, it is found that the n/sub ij/ depend sensitively on the displacement thresholds, with very dramatic charges occuring when the two thresholds become significantly different from one another

  7. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Sinuses Computed tomography (CT) of the sinuses uses special x-ray equipment ... story here Images × Image Gallery Patient undergoing computed tomography (CT) scan. View full size with caption Pediatric Content ...

  8. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Head Computed tomography (CT) of the head uses special x-ray equipment ... story here Images × Image Gallery Patient undergoing computed tomography (CT) scan. View full size with caption Pediatric Content ...

  9. Image-guided stereotactic surgery using ultrasonography and reconstructive three-dimensional CT-imaging system

    International Nuclear Information System (INIS)

    Kawamura, Hirotsune; Iseki, Hiroshi; Umezawa, Yoshihiro

    1991-01-01

    A new simulation and navigation system utilizing three-dimensional CT images has been developed for image-guided stereotactic surgery. Preoperative CT images are not always useful in predicting the intraoperative location of lesions, for cerebral lesions are easily displaced or distorted by gravity, brain retraction, and/or CSF aspiration during operative procedure. This new system, however, has the advantage that the intraoperative locations of intracranial lesions or the anatomical structures of the brain can be precisely confirmed during stereotactic surgery. Serial CT images were obtained from a patient whose head had been fixed to the ISEKI CT-guided stereotactic frame. The data of serial CT images were saved on a floppy disc and then transferred to the work station (IRIS) using the off line. In order to find the best approach angle for ultrasound-guided stereotactic surgery, three-dimenstional CT images were reconstructed using the work station. The site of the craniotomy or the angle of the trajectory of the ultrasound probe was measured preoperatively based on the three-dimensional CT images. Then, in the operating room, the patient's head was fixed to the ISEKI frame with the subframe at the same position as before according to the measurement of the CT images. In a case of cystic glioma, the predicable ultrasonograms from three-dimensional reconstructive CT images were ascertained to correspond well to the actual ultrasound images during ultrasound-guided stereotactic surgery. Therefore, the new simulation and navigation system can be judged to be a powerful operative supporting modality for correcting the locations of cerebral lesions; it allows one to perform stereotactic surgery more accurately and less invasively. (author)

  10. Displacer Diameter Effect in Displacer Pulse Tube Refrigerator

    Science.gov (United States)

    Zhu, Shaowei

    2017-12-01

    Gas driving displacer pulse tube refrigerators are one of the work recovery type of pulse tube refrigerators whose theoretical efficiency is the same as Stirling refrigerators'. Its cooling power is from the displacement of the displacer. Displace diameter, rod diameter and pressure drop of the regenerator influence the displacement, which are investigated by numerical simulation. It is shown that the displacement ratio of the displacer over the piston is almost not affected by the displacer diameter at the same rod diameter ratio, or displacer with different diameters almost has the same performance.

  11. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Children's (Pediatric) CT (Computed Tomography) Pediatric computed tomography (CT) is ... a CT scan. View full size with caption Pediatric Content Some imaging tests and treatments have special ...

  12. Pretreatment evaluation of distant-site status in patients with nasopharyngeal carcinoma: accuracy of whole-body MRI at 3-Tesla and FDG-PET-CT

    International Nuclear Information System (INIS)

    Ng, Shu-Hang; Chan, Sheng-Chieh; Yen, Tzu-Chen; Chang, Joseph Tung-Chieh; Liao, Chun-Ta; Ko, Sheung-Fat; Wai, Yau-Yau; Wang, Hung-Ming; Wang, Jiun-Jie; Chen, Min-Chi

    2009-01-01

    We sought to prospectively evaluate the accuracy of 3.0-Tesla whole-body magnetic resonance imaging (WB-MRI) and integrated fluorodeoxyglucose (FDG) positron emission tomography (PET)/computed tomography (CT) (FDG-PET-CT), and their combined interpretation for the assessment of distant-site status in 150 patients with untreated nasopharyngeal carcinoma (NPC). Eighteen (12%) patients were diagnosed as having distant malignancies (15 patients had distant metastases, and three distant synchronous tumours). On a patient-based analysis, WB-MRI and FDG-PET-CT showed similar sensitivity (77.8% vs 72.2%, P > 0.999), specificity (98.5% vs 97.7%, P > 0.999) and diagnostic capability (0.905 vs 0.878, P = 0.669). Combined interpretation of WB-MRI and FDG-PET-CT showed no significant benefit over either technique alone. In conclusion, 3.0-Tesla WB-MRI is a feasible, non-ionising technique that showed similar diagnostic capacity to FDG-PET-CT in assessing distant-site status in patients with untreated NPC and can be recommended as the first-line imaging technique for comprehensive evaluation of such patients. (orig.)

  13. Earthquake damage to underground facilities and earthquake related displacement fields

    International Nuclear Information System (INIS)

    Pratt, H.R.; Stephenson, D.E.; Zandt, G.; Bouchon, M.; Hustrulid, W.A.

    1982-01-01

    The potential seismic risk for an underground facility is considered in the evaluation of its location and design. The possible damage resulting from either large-scale displacements or high accelerations should be considered in evaluating potential sites of underground facilities. Scattered through the available literature are statements to the effect that below a few hundred meters shaking and damage in mines is less than at the surface; however, data for decreased damage underground have not been completely reported or explained. In order to assess the seismic risk for an underground facility, a data base was established and analyzed to evaluate the potential for seismic disturbance. Substantial damage to underground facilities is usually the result of displacements primarily along pre-existing faults and fractures, or at the surface entrance to these facilities. Evidence of this comes from both earthquakes as a function of depth is important in the evaluation of the hazard to underground facilities. To evaluate potential displacements due to seismic effects of block motions along pre-existing or induced fractures, the displacement fields surrounding two types of faults were investigated. Analytical models were used to determine relative displacements of shafts and near-surface displacement of large rock masses. Numerical methods were used to determine the displacement fields associated with pure strike-slip and vertical normal faults. Results are presented as displacements for various fault lengths as a function of depth and distance. This provides input to determine potential displacements in terms of depth and distance for underground facilities, important for assessing potential sites and design parameters

  14. Initial investigation of 18F-NaF PET/CT for identification of vertebral sites amenable to surgical revision after spinal fusion surgery

    International Nuclear Information System (INIS)

    Quon, Andrew; Iagaru, Andrei; Dodd, Robert; Abreu, Marcelo Rodrigues de; Sprinz, Clarice; Hennemann, Sergio; Alves Neto, Jose Maria

    2012-01-01

    A pilot study was performed in patients with recurrent back pain after spinal fusion surgery to evaluate the ability of 18 F-NaF PET/CT imaging to correctly identify those requiring surgical intervention and to locate a site amenable to surgical intervention. In this prospective study 22 patients with recurrent back pain after spinal surgery and with equivocal findings on physical examination and CT were enrolled for evaluation with 18 F-NaF PET/CT. All PET/CT images were prospectively reviewed with the primary objective of identifying or ruling out the presence of lesions amenable to surgical intervention. The PET/CT results were then validated during surgical exploration or clinical follow-up of at least 15 months. Abnormal 18 F-NaF foci were found in 16 of the 22 patients, and surgical intervention was recommended. These foci were located at various sites: screws, cages, rods, fixation hardware, and bone grafts. In 6 of the 22 patients no foci requiring surgical intervention were found. Validation of the results by surgery (15 patients) or on clinical follow-up (7 patients) showed that 18 F-NaF PET/CT correctly predicted the presence of an abnormality requiring surgical intervention in 15 of 16 patients and was falsely positive in 1 of 16. In this initial investigation, 18 F-NaF PET/CT imaging showed potential utility for evaluation of recurrent symptoms after spinal fusion surgery by identifying those patients requiring surgical management. (orig.)

  15. Improved quantitation and reproducibility in multi-PET/CT lung studies by combining CT information.

    Science.gov (United States)

    Holman, Beverley F; Cuplov, Vesna; Millner, Lynn; Endozo, Raymond; Maher, Toby M; Groves, Ashley M; Hutton, Brian F; Thielemans, Kris

    2018-06-05

    Matched attenuation maps are vital for obtaining accurate and reproducible kinetic and static parameter estimates from PET data. With increased interest in PET/CT imaging of diffuse lung diseases for assessing disease progression and treatment effectiveness, understanding the extent of the effect of respiratory motion and establishing methods for correction are becoming more important. In a previous study, we have shown that using the wrong attenuation map leads to large errors due to density mismatches in the lung, especially in dynamic PET scans. Here, we extend this work to the case where the study is sub-divided into several scans, e.g. for patient comfort, each with its own CT (cine-CT and 'snap shot' CT). A method to combine multi-CT information into a combined-CT has then been developed, which averages the CT information from each study section to produce composite CT images with the lung density more representative of that in the PET data. This combined-CT was applied to nine patients with idiopathic pulmonary fibrosis, imaged with dynamic 18 F-FDG PET/CT to determine the improvement in the precision of the parameter estimates. Using XCAT simulations, errors in the influx rate constant were found to be as high as 60% in multi-PET/CT studies. Analysis of patient data identified displacements between study sections in the time activity curves, which led to an average standard error in the estimates of the influx rate constant of 53% with conventional methods. This reduced to within 5% after use of combined-CTs for attenuation correction of the study sections. Use of combined-CTs to reconstruct the sections of a multi-PET/CT study, as opposed to using the individually acquired CTs at each study stage, produces more precise parameter estimates and may improve discrimination between diseased and normal lung.

  16. CT findings of orbital inflammatory diseases

    International Nuclear Information System (INIS)

    Kim, Jang Min; Shin, Hyun Joon; Kim, Jung Hyuk; Suh, Won Hyuck

    1991-01-01

    Twenty-nine patients with orbital inflammatory disease (OIDs) were retrospectively reviewed in order to analyze detailed CT findings which might aid in differentiating OIDs. This study comprised 18 pseudotumors, 5 thyroid ophthalmopathies, and 6 cases of orbital cellulitis. CT scans of the pseudotumors showed various findings such as exophthalmos, scleritis, myositis of the extraocular muscle (MOM), and bone lesion. Bone lesions of the pseudo tumors, which have been rarely reported, were present in 7 cases in our series. Bilateral exophthalmos, myositis, and retrobulbar fat deposition were readily detected by CT in thyroid ophthalmopathy, and, in addition, we found bone erosions involving the orbital apices in 2 cases. In orbital cellulitis, extraorbital soft tissue swelling and lateral displacement of the medial rectus muscle in cases with ethmoiditis were the most conspicuous features. In summary, because of the overlapping CT findings in OIDs, careful examination of CT findings regarding the mode of EOM involvement and the presence or absence of scleritis or sinusitis might help narrow down the differential diagnosis. A pseudotumor with bone lesions could be mistaken as a malignant lesion, and therefore it is necessary to correlate clinical features with CT findings for an accurate diagnosis

  17. Low-dose non-enhanced CT versus full-dose contrast-enhanced CT in integrated PET/CT studies for the diagnosis of uterine cancer recurrence

    Energy Technology Data Exchange (ETDEWEB)

    Kitajima, Kazuhiro [Institute of Biomedical Research and Innovation, Department of PET Diagnosis, Kobe (Japan); Kobe University Graduate School of Medicine, Department of Radiology, Kobe (Japan); Suzuki, Kayo [Institute of Biomedical Research and Innovation, Department of PET Diagnosis, Kobe (Japan); Nakamoto, Yuji [Kyoto University Hospital, Department of Diagnostic Radiology, Kyoto (Japan); Onishi, Yumiko; Sakamoto, Setsu; Sugimura, Kazuro [Kobe University Graduate School of Medicine, Department of Radiology, Kobe (Japan); Senda, Michio [Institute of Biomedical Research and Innovation, Department of Molecular Imaging, Kobe (Japan); Kita, Masato [Kobe City Medical Center General Hospital, Department of Obstetrics and Gynecology, Kobe (Japan)

    2010-08-15

    To evaluate low-dose non-enhanced CT (ldCT) and full-dose contrast-enhanced CT (ceCT) in integrated {sup 18}F-fluorodeoxyglucose (FDG) PET/CT studies for restaging of uterine cancer. A group of 100 women who had undergone treatment for uterine cervical (n=55) or endometrial cancer (n=45) underwent a conventional PET/CT scans with ldCT, and then a ceCT scan. Two observers retrospectively reviewed and interpreted the PET/ldCT and PET/ceCT images in consensus using a three-point grading scale (negative, equivocal, or positive) per patient and per lesion. Final diagnoses were obtained by histopathological examination, or clinical follow-up for at least 6 months. Patient-based analysis showed that the sensitivity, specificity and accuracy of PET/ceCT were 90% (27/30), 97% (68/70) and 95% (95/100), respectively, whereas those of PET/ldCT were 83% (25/30), 94% (66/70) and 91% (91/100), respectively. Sensitivity, specificity and accuracy did not significantly differ between two methods (McNemar test, p=0.48, p=0.48, and p=0.13, respectively). There were 52 sites of lesion recurrence: 12 pelvic lymph node (LN), 11 local recurrence, 8 peritoneum, 7 abdominal LN, 5 lung, 3 supraclavicular LN, 3 liver, 2 mediastinal LN, and 1 muscle and bone. The grading results for the 52 sites of recurrence were: negative 5, equivocal 0 and positive 47 for PET/ceCT, and negative 5, equivocal 4 and positive 43 for PET/ldCT, respectively. Four equivocal regions by PET/ldCT (local recurrence, pelvic LN metastasis, liver metastasis and muscle metastasis) were correctly interpreted as positive by PET/ceCT. PET/ceCT is an accurate imaging modality for the assessment of uterine cancer recurrence. Its use reduces the frequency of equivocal interpretations. (orig.)

  18. Comparison of plain radiography and CT in postoperative evaluation of ankle fractures

    International Nuclear Information System (INIS)

    Chen, Y.; Zhang, K.; Qiang, M.; Li, H.; Dai, H.

    2015-01-01

    Aim: To compare postoperative plain radiographs with computed tomography (CT) post-processing images in evaluating the quality of anatomical reduction and internal fixation of ankle fractures. Materials and methods: A total of 168 patients who sustained closed ankle fracture and were treated with open reduction and internal fixation in East Hospital were reviewed. Postoperative plain radiographs and CT post-processing images were evaluated. The observation was performed under volume-rendering mode and multiplanar reconstruction mode. The assessment was performed by two independent orthopaedic surgeons. The inter- and intra-observer variations were analysed by kappa statistics. The differences between plain radiographs and CT post-processing images were compared using χ 2 test (McNemar's test). Results: Inter- and intra-observer agreement was almost perfect (0.813–1.000) using CT post-processing images, which was higher than that using plain radiographs (0.323–0.848). More non-anatomical reduction could be recognised in the supination–external rotation (SER), supination–adduction (SAD), pronation–external rotation (PER), and overall groups (p<0.05) and more poor internal fixation could be recognised in the SER, SAD, and overall groups (p<0.05) using CT post-processing images than using radiographs. Conclusion: More residual articular step, fracture fragment displacement, and poor internal fixation could be detected by CT post-processing images than plain radiographs. -- Highlights: •We compared postoperative X-rays with CT images in ankle fractures. •The evaluation agreement using CT images was higher than X-rays. •CT images detect more residual articular steps than X-rays. •CT images detect more fracture fragment displacement than X-rays. •CT images detect more poor internal fixation than X-rays

  19. CT findings predictive of neurological deficits in throracolumbar burst fractures

    Energy Technology Data Exchange (ETDEWEB)

    Moon, Tae Yong; Jeong, Hee Seok; Jeong, Yeo Jin [Pusan National University and Research Institute for Convergence of Biomedical Science and Technology, Dept. of Radiology, Pusan National University Yangsan Hospital, Yangsan (Korea, Republic of); Lee, In Sook [Dept. of Radiology, Pusan National University Hospital, Busan (Korea, Republic of)

    2016-09-15

    To determine the computed tomography (CT) findings predictive of neurological deficits in thoracolumbar spine injuries. One hundred two patients with thoracolumbar spinal burst fractures, after excluding the patients with brain and cervical cord injuries and unconsciousness, who underwent consecutive spine 128-multidetector CT scan formed the study group. The neurological findings were clinically classified as no deficit (n = 58), complete deficit with paraplegia (n = 22), and incomplete deficit with either motor or sensory impairment (n = 22). The following four CT imaging parameters were analyzed: the level of the main burst fracture as the cord (n = 44) and the cauda equina (n = 58) levels; the extent of canal encroachment as central canal ratios (CCRs) below 0.5 (n = 43) and above 0.5 (n = 59); the degree of laminar fracture as no fracture (n = 33), linear fracture (n = 7), separated fracture (n = 27), and displaced fracture (n = 35); fractured vertebra counted as single (n = 53) and multiple (n = 49). Complete neurological deficit was associated with injuries at the cord level (p = 0.000) and displaced laminar fractures (p = 0.000); incomplete neurological deficit was associated with CCRs below 0.5 (p = 0.000) and multiple vertebral injuries (p = 0.002). CT scan can provide additional findings predictive of neurological deficits in thoracolumbar spinal burst fractures.

  20. MicroCT analysis of calcium/phosphorus ratio maps at different bone sites

    Energy Technology Data Exchange (ETDEWEB)

    Speller, R. [Medical Physics and Bioengineering Department, UCL, London, WC1E 6BT (United Kingdom)]. E-mail: rspeller@medphys.ucl.ac.uk; Pani, S. [Department of Physics, University of Trieste (Italy); Tzaphlidou, M. [Lab Medical Physics, Medical School, University of Ioannina, 45110 Ioannina (Greece); Horrocks, J. [Clinical Physics Group, St Bartholomew' s Hospital, London, EC1A 6BT (United Kingdom)

    2005-08-11

    The Ca/P ratio was measured in cortical bone samples from the femoral neck, front and rear tibia of rats, rabbits and lambs using synchrotron microCT. Use of a monoenergetic X-ray beam, as provided by the synchrotron facility, generates accurate 3-D maps of the linear attenuation coefficient within the sample and hence gives the ability to map different chemical components. Data were taken at 20keV for each bone sample and calibration phantoms. From the 3-D data sets, multiple 2-D slices were reconstructed with a slice thickness of {approx}28{mu}m and converted to Ca/P ratios using the calibration phantom results. Average values for each animal and bone site were estimated. Differences between the same bone sites from different animals are not significant (0.3sites and different animals are highly significant (p<10{sup -3}) demonstrating a dependence upon lifestyle and bone use. The spatial distribution of Ca/P was found to be non-uniform for some bones and some animals possibly indicating the structural mechanism for obtaining bone strength.

  1. Helical CT in acute lower gastrointestinal bleeding

    International Nuclear Information System (INIS)

    Ernst, Olivier; Leroy, Christophe; Sergent, Geraldine; Bulois, Philippe; Saint-Drenant, Sophie; Paris, Jean-Claude

    2003-01-01

    The purpose of this study was to assess the usefulness of helical CT in depicting the location of acute lower gastrointestinal bleeding. A three-phase helical CT of the abdomen was performed in 24 patients referred for acute lower gastrointestinal bleeding. The diagnosis of the bleeding site was established by CT when there was at least one of the following criteria: spontaneous hyperdensity of the peribowel fat; contrast enhancement of the bowel wall; vascular extravasation of the contrast medium; thickening of the bowel wall; polyp or tumor; or vascular dilation. Diverticula alone were not enough to locate the bleeding site. The results of CT were compared with the diagnosis obtained by colonoscopy, enteroscopy, or surgery. A definite diagnosis was made in 19 patients. The bleeding site was located in the small bowel in 5 patients and the colon in 14 patients. The CT correctly located 4 small bowel hemorrhages and 11 colonic hemorrhages. Diagnosis of the primary lesion responsible for the bleeding was made in 10 patients. Our results suggest that helical CT could be a good diagnostic tool in acute lower gastrointestinal bleeding to help the physician to diagnose the bleeding site. (orig.)

  2. Applying an animal model to quantify the uncertainties of an image-based 4D-CT algorithm

    International Nuclear Information System (INIS)

    Pierce, Greg; Battista, Jerry; Wang, Kevin; Lee, Ting-Yim

    2012-01-01

    The purpose of this paper is to use an animal model to quantify the spatial displacement uncertainties and test the fundamental assumptions of an image-based 4D-CT algorithm in vivo. Six female Landrace cross pigs were ventilated and imaged using a 64-slice CT scanner (GE Healthcare) operating in axial cine mode. The breathing amplitude pattern of the pigs was varied by periodically crimping the ventilator gas return tube during the image acquisition. The image data were used to determine the displacement uncertainties that result from matching CT images at the same respiratory phase using normalized cross correlation (NCC) as the matching criteria. Additionally, the ability to match the respiratory phase of a 4.0 cm subvolume of the thorax to a reference subvolume using only a single overlapping 2D slice from the two subvolumes was tested by varying the location of the overlapping matching image within the subvolume and examining the effect this had on the displacement relative to the reference volume. The displacement uncertainty resulting from matching two respiratory images using NCC ranged from 0.54 ± 0.10 mm per match to 0.32 ± 0.16 mm per match in the lung of the animal. The uncertainty was found to propagate in quadrature, increasing with number of NCC matches performed. In comparison, the minimum displacement achievable if two respiratory images were matched perfectly in phase ranged from 0.77 ± 0.06 to 0.93 ± 0.06 mm in the lung. The assumption that subvolumes from separate cine scan could be matched by matching a single overlapping 2D image between to subvolumes was validated. An in vivo animal model was developed to test an image-based 4D-CT algorithm. The uncertainties associated with using NCC to match the respiratory phase of two images were quantified and the assumption that a 4.0 cm 3D subvolume can by matched in respiratory phase by matching a single 2D image from the 3D subvolume was validated. The work in this paper shows the image-based 4D-CT

  3. CT image registration in sinogram space.

    Science.gov (United States)

    Mao, Weihua; Li, Tianfang; Wink, Nicole; Xing, Lei

    2007-09-01

    Object displacement in a CT scan is generally reflected in CT projection data or sinogram. In this work, the direct relationship between object motion and the change of CT projection data (sinogram) is investigated and this knowledge is applied to create a novel algorithm for sinogram registration. Calculated and experimental results demonstrate that the registration technique works well for registering rigid 2D or 3D motion in parallel and fan beam samplings. Problem and solution for 3D sinogram-based registration of metallic fiducials are also addressed. Since the motion is registered before image reconstruction, the presented algorithm is particularly useful when registering images with metal or truncation artifacts. In addition, this algorithm is valuable for dealing with situations where only limited projection data are available, making it appealing for various applications in image guided radiation therapy.

  4. CT image registration in sinogram space

    International Nuclear Information System (INIS)

    Mao Weihua; Li Tianfang; Wink, Nicole; Xing Lei

    2007-01-01

    Object displacement in a CT scan is generally reflected in CT projection data or sinogram. In this work, the direct relationship between object motion and the change of CT projection data (sinogram) is investigated and this knowledge is applied to create a novel algorithm for sinogram registration. Calculated and experimental results demonstrate that the registration technique works well for registering rigid 2D or 3D motion in parallel and fan beam samplings. Problem and solution for 3D sinogram-based registration of metallic fiducials are also addressed. Since the motion is registered before image reconstruction, the presented algorithm is particularly useful when registering images with metal or truncation artifacts. In addition, this algorithm is valuable for dealing with situations where only limited projection data are available, making it appealing for various applications in image guided radiation therapy

  5. Role of CT for dissecting aneurysm of aorta

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Hee Tae; Kim, Hong Gil; Park, Choong Ki; Lee, Young Joong; Yoon, Jong Sup [College of Medicine, Hallym University, Chunchun (Korea, Republic of)

    1987-06-15

    During a three years period, 11 patients with clinically suspected aortic dissection were diagnosed by CT as the primary mode of investigation. Chest roentgenography was performed in all 11 patients and ultrasonography was performed in 2 patients. None of them obtained aortography. The authors analyzed them and obtained the results as follows : 1. 7 cases were female and 4 male, with a mean age of 65 years (range 53-75 years) 2. All of them suffered from hypertension. The most consistent clinical symptom was severe tearing chest pain which was radiating to back. ECG revealed the findings of LVH in all 11 cases. 5 cases were expired within 2 weeks and 6 cases treated medically with symptomatic improvement. 3. Chest roentgenography revealed suggestive signs of dissecting aortic aneurysm such as widening of superior mediastinum, shifting of trachea to the right side, obliteration of aortic knob, double aortic knob, displacement of intimal calcification and pleural effusion. 4. CT findings proffered us useful information which were double channel with intimal flap, displacement of intimal calcification, thrombosis, increased diameter of aorta, pleural and pericardial effusion, and narrowness of true lumen. 5. The authors recommend a CT study as the most important preliminary examination in all suspected cases of dissecting aortic aneurysm even though it has some limitation.

  6. Role of CT for dissecting aneurysm of aorta

    International Nuclear Information System (INIS)

    Chung, Hee Tae; Kim, Hong Gil; Park, Choong Ki; Lee, Young Joong; Yoon, Jong Sup

    1987-01-01

    During a three years period, 11 patients with clinically suspected aortic dissection were diagnosed by CT as the primary mode of investigation. Chest roentgenography was performed in all 11 patients and ultrasonography was performed in 2 patients. None of them obtained aortography. The authors analyzed them and obtained the results as follows : 1. 7 cases were female and 4 male, with a mean age of 65 years (range 53-75 years) 2. All of them suffered from hypertension. The most consistent clinical symptom was severe tearing chest pain which was radiating to back. ECG revealed the findings of LVH in all 11 cases. 5 cases were expired within 2 weeks and 6 cases treated medically with symptomatic improvement. 3. Chest roentgenography revealed suggestive signs of dissecting aortic aneurysm such as widening of superior mediastinum, shifting of trachea to the right side, obliteration of aortic knob, double aortic knob, displacement of intimal calcification and pleural effusion. 4. CT findings proffered us useful information which were double channel with intimal flap, displacement of intimal calcification, thrombosis, increased diameter of aorta, pleural and pericardial effusion, and narrowness of true lumen. 5. The authors recommend a CT study as the most important preliminary examination in all suspected cases of dissecting aortic aneurysm even though it has some limitation

  7. Temporomandibular joint assessment in patients with articular disc displacement by way of computed tomography - radiological parameters of shape, size and location of mandibular heads

    Directory of Open Access Journals (Sweden)

    Szabelska Anna

    2015-09-01

    Full Text Available Conventional and modern methods of radiological imaging are often used in the diagnosis of temporomandibular joint disorders, and the CT technique is particularly characterized by an excellent visualization of bony structures. The aim of the study was to show the importance and role of CT in the evaluation of TMJ bone structures in both patients with articular disc displacement and in a group of healthy subjects. Both study groups were assessed with the use of the transverse plane. Herein, multi-slice spiral computed tomography was performed in 47 subjects. These individuals were qualified for CT by way of magnetic resonance imaging, due to their being diagnosed with a displacement of their temporomandibular joint disc. The product of our study is presented as a set of tables. These are comparisons of radiological parameters based on the shape, size and location of the mandibular head, in the examined patients, in a control group, and with regard to sex. The results of our work indicate that CT can be successfully used in the imaging of TMJ bone structures, specifically, the condylar process of the mandibular head and the joint socket. However, statistically significant differences of the utilized parameters between patients with articular disc displacement and controls, warrant further analysis of this issue.

  8. CT findings of superior vena cava syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Jun; Lee, Jae Mun; Kim, Choon Yul; Bahk, Yong Whee [Catholic Medical College, Seoul (Korea, Republic of)

    1986-10-15

    Since early 1980's high resolution CT has been used for detection of intrathoracic pathologic condition such as superior vena cava syndrome. Authors retrospectively analysed CT findings of 18 cases of proven SVC syndrome. The results were as follows: 1. The mean age was 50-year-old, and 14 cases were male. 2. Of 18 cases of SVC syndrome, 8 cases had confirmed to be lung cancers, malignant thymoma and teratoma were respectively each 2 cases, and malignant lymphoma, mediastinal abscess, thyroid adenoma and metastatic tumor were 1 case. 3. CT findings were A. Abnormal SVC consisted of compression with displacement (44.4%), intraluminal thrombus (27.8%), and encasement (27.8%). B. The collateral pathways were the azygos-homozygous (88.8%), vertebral (50%), internal mammary (44.4%), and lateral thoracic route (33.3%)

  9. CT findings of superior vena cava syndrome

    International Nuclear Information System (INIS)

    Lim, Jun; Lee, Jae Mun; Kim, Choon Yul; Bahk, Yong Whee

    1986-01-01

    Since early 1980's high resolution CT has been used for detection of intrathoracic pathologic condition such as superior vena cava syndrome. Authors retrospectively analysed CT findings of 18 cases of proven SVC syndrome. The results were as follows: 1. The mean age was 50-year-old, and 14 cases were male. 2. Of 18 cases of SVC syndrome, 8 cases had confirmed to be lung cancers, malignant thymoma and teratoma were respectively each 2 cases, and malignant lymphoma, mediastinal abscess, thyroid adenoma and metastatic tumor were 1 case. 3. CT findings were A. Abnormal SVC consisted of compression with displacement (44.4%), intraluminal thrombus (27.8%), and encasement (27.8%). B. The collateral pathways were the azygos-homozygous (88.8%), vertebral (50%), internal mammary (44.4%), and lateral thoracic route (33.3%).

  10. Displacive stability of a void in a void lattice

    International Nuclear Information System (INIS)

    Brailsford, A.D.

    1977-01-01

    It has recently been suggested that the stability of the void-lattice structure in irradiated metals may be attributed to the effect of the overlapping of the point-defect diffusion fields associated with each void. It is shown here, however, that the effect is much too weak. When one void is displaced from its lattice site, the displacement is shown to relax to zero as proposed, but a conservative estimate indicates that the characteristic time is equivalent to an irradiation dose of the order of 300 displacements per atom which is generally much greater than the dose necessary for void-lattice formation

  11. Gender-based violence in conflict and displacement: qualitative findings from displaced women in Colombia.

    Science.gov (United States)

    Wirtz, Andrea L; Pham, Kiemanh; Glass, Nancy; Loochkartt, Saskia; Kidane, Teemar; Cuspoca, Decssy; Rubenstein, Leonard S; Singh, Sonal; Vu, Alexander

    2014-01-01

    Gender-based violence (GBV) is prevalent among, though not specific to, conflict affected populations and related to multifarious levels of vulnerability of conflict and displacement. Colombia has been marked with decades of conflict, with an estimated 5.2 million internally displaced persons (IDPs) and ongoing violence. We conducted qualitative research to understand the contexts of conflict, displacement and dynamics with GBV. This as part of a multi-phase, mixed method study, in collaboration with UNHCR, to develop a screening tool to confidentially identify cases of GBV for referral among IDP women who were survivors of GBV. Qualitative research was used to identify the range of GBV, perpetrators, contexts in conflict and displacement, barriers to reporting and service uptake, as well as to understand experiences of service providers. Thirty-five female IDPs, aged 18 years and older, who self-identified as survivors of GBV were enrolled for in-depth interviews in San Jose de Guaviare and Quibdo, Colombia in June 2012. Thirty-one service providers participated in six focus group discussions and four interviews across these sites. Survivors described a range of GBV across conflict and displacement settings. Armed actors in conflict settings perpetrated threats of violence and harm to family members, child recruitment, and, to a lesser degree, rape and forced abortion. Opportunistic violence, including abduction, rape, and few accounts of trafficking were more commonly reported to occur in the displacement setting, often perpetrated by unknown individuals. Intrafamilial violence, intimate partner violence, including physical and sexual violence and reproductive control were salient across settings and may be exacerbated by conflict and displacement. Barriers to reporting and services seeking were reported by survivors and providers alike. Findings highlight the need for early identification of GBV cases, with emphasis on confidential approaches and active

  12. CT in neuromuscular disorders: A comparison of CT and histology

    International Nuclear Information System (INIS)

    Vliet, A.M. van der; Thijssen, H.O.M.; Merx, J.L.; Joosten, E.

    1988-01-01

    The value of CT-examination of the muscles compared to histology was studied in a retrospective analysis of 30 patients with clinical suspicion of neuromuscular disorder. In the evaluation of the CT-results descriptive criteria were used. The histologic diagnosis came from needle-biopsies taken from the quadriceps muscle. Considering the whole group of neuromuscular disorders, CT has an overall accuracy of 84.8%, a positive predictive value of 95.5% and a negative predictive value of 63.6%. This makes the use of CT as a diagnostic tool in neuromuscular disorders a reliable examination technique. In patients with a polymyositis there is even a 100% correlation between CT findings and biopsy results. Discrepancy between the biopsy results is remarkable of the quadriceps muscle and the CT findings: The number of abnormal histological findings is twice the number of abnormal CT findings. Using the more proximal gluteal region as a biopsy site would have decreased this discrepancy and would therefore have given a better correlation between CT and histology. The choice of protocol in determining the levels to be scanned is of great importance in achieving good reproducability in follow-up CT examinations. (orig.)

  13. CT recognition of lateral lumbar disk herniation

    International Nuclear Information System (INIS)

    Williams, A.L.; Haughton, V.M.; Daniels, D.L.; Thornton, R.S.

    1982-01-01

    Although computed tomography (CT) has been shown to be useful in diagnosing posterolateral and central lumbar disk herniations, its effectiveness in demonstrating lateral herniated disks has not been emphasized. The myelographic recognition of those herniations may be difficult because root sheaths or dural sacs may not be deformed. A total of 274 CT scans interpreted as showing lumbar disk herniation was reviewed. Fourteen (5%) showed a lateral disk herniation. The CT features of a lateral herniated disk included: (1) focal protrusion of the disk margin within or lateral to the intervertebral foramen: (2) displacement of epidural fat within the intervertebral foramen; (3) absence of dural sac deformity; and (4) soft-tissue mass within or lateral to the intervertebral foramen. Because it can image the disk margin and free disk fragments irrespective of dural sac or root sheath deformity, CT may be more effective than myelography for demonstrating the presence and extent of lateral disk herniation

  14. Significance of performing CT after radiofrequency ablation of hepatocellular carcinoma. Relationship between CT findings in areas other than the tumor site and post therapeutic outcome

    International Nuclear Information System (INIS)

    Shimokoube, Kouichi; Saito, Kazuhiro; Kotake, Fumio; Nakamura, Hiroshi; Mizokami, Yuji; Mikami, Ryuji; Matsuoka, Takeshi

    2004-01-01

    The relationships between the CT findings following radiofrequency ablation (RFA) of hepatocellular carcinoma (HCC) and the clinical symptoms and laboratory data were examined. The subjects consisted of 31 cases (41 nodules) of HCC that were treated by RFA. The CT findings before and after RFA, particularly the findings in areas other than the treatment site (henceforth, secondary findings), were evaluated by a physician and a radiologist. In addition, the relationships between the CT findings and post-RFA clinical symptoms (fever/pain) and laboratory data were examined. Secondary findings were found in 90.3% (28/31). These findings were broadly classified into changes in the needle tract 51.6% (16/31), retention of effusion 41.9% (13/31), thickening of the gallbladder wall 12.9% (4/31), changes in the retroperitoneal space 9.7% (3/31), and dilatation of the intrahepatic bile duct 3.2% (1/31), in the order of frequency. A relationship was found between changes in the retroperitoneal space and the clinical symptoms (fever: p=0.0366, pain: p=0.0012). Relationships were also found between changes in the needle tract and retention of effusion and aspartate aminotransferase (AST) (p<0.0001), as well as between changes in the needle tract and alanine aminotransferase (ALT) (p=0.0149). The size of the treatment area did not correlate with the presence of clinical symptoms and changes in laboratory data. Diverse classification of CT findings was observed after RFA, and a relationship with clinical symptoms was noted. A relationship was also found between classification of the CT findings following RFA and the post-therapeutic outcome. (authors)

  15. Focal CT abnormality and epileptogenic focus

    International Nuclear Information System (INIS)

    Yagi, Kazuichi; Mihara, Tadahiro; Tottori, Takayasu; Matsuda, Kazumi; Watanabe, Yutaka; Seino, Masakazu

    1989-01-01

    In 31 patients with temporal lobe epilepsy, the precise site of epileptogenic focus was determined by means of a depth EEG recording as one of the presurgical evaluations. In 13 patients, a CT scan revealed focal lesions; 7 in the left temporal lobe and 6 in the right temporal lobe. In 5 of the 7 patients and in 5 of the 6 patients the epileptogenic foci were determined in the temporal lobe on the side of a CT lesion. However, in 2 of the patients with a CT lesion in the left temporal lobe, independent epileptogenic foci were found in both the temporal lobes, and in the other patient with a CT lesion in the right temporal lobe, they were found in the right frontal and left temporal lobes. Thus, the CT lesions agreed in lateralization and focality with the epileptogenic foci in 10 of the 13 patients (77%), but they disagreed in 3 (23%). A CT lesion disclosed in the temporal lobe does not necessarily indicate the side and/or site where the epileptogenic focus may be localized. Although exceptions may be made, spatial disagreement was exemplified between the CT lesion and epileptogenic focus. Therefore, extreme caution has to be taken on the side and/or site of the epileptogenic focus when functional surgical indication is to be made. (author)

  16. SU-E-J-167: Dosimetric Consequences From Minimal Displacements in APBI with SAVI Applicators

    Energy Technology Data Exchange (ETDEWEB)

    Chandrasekara, S; Dumitru, N [Bucharest (Romania); Hyvarinen, M [Florida Atlantic University, Boca Raton, FL (United States); Pella, S [South Florida Radiation Oncology, Boca Raton, FL (United States)

    2015-06-15

    Purpose: To determine the importance of providing proper solid immobilization in every fraction of treatment in APBI with brachytherapy. Methods: 125 patients treated with APBI brachytherapy with SAVI applicators at SFRO Boca Raton, from 2013–2015 were considered for this retrospective study. The CT scans of each patient, which were taken before each treatment, were imported in to the Oncentra treatment planning system. Then they were compared with the initial CT scan which was used for the initial plan. Deviation in displacements in reference to ribs and skin surface was measured and dosimetric evaluations respective to the initial image were performed. Results: Small deviations in displacements were observed from the SAVI applicator to the ribs and the skin surface. Dosimetric evaluations revealed, very small changes in the inter-fractionation position make significant differences in the maximum dose to critical organs. Additionally, the volume of the cavity also changed between fractions. As a Result, the maximum dose manifested variance between 10% and 32% in ribs and skin surface respectively. Conclusion: It appears that taking a CT scan before each treatment is necessary to minimize the risk of delivering undesired high doses to the critical organs. This study indicates, in 30% of the cases re-planning was necessary between treatments. We conclude that, treatment planning teams should evaluate the placement of the device by analyzing the CT images before each treatment and they must be prepared for re-planning if needed. This study also reveals the urgent need of improving the immobilization methods with APBI when treating with the SAVI applicator.

  17. Metallic artifacts caused by dental metal prostheses on PET images. A PET/CT phantom study using different PET/CT scanners

    International Nuclear Information System (INIS)

    Shimamoto, Hiroaki; Kakimoto, Naoya; Murakami, Shumei; Furukawa, Souhei; Fujino, Kouichi; Hamada, Seiki; Shimosegawa, Eku; Hatazawa, Jun

    2009-01-01

    The objective of this study was to investigate the effects of computed tomography (CT) artifacts caused by dental metal prostheses on positron emission tomography (PET) images. A dental arch cast was fixed in a cylindrical water-bath phantom. A spherical phantom positioned in the vicinity of the dental arch cast was used to simulate a tumor. To simulate the tumor imaging, the ratio of the 18 F-fluoro-deoxy-glucose radioactivity concentration of the spherical phantom to that of the water-bath phantom was set at 2.5. A dental bridge composed of a gold-silver-palladium alloy on the right mandibular side was prepared. A spherical phantom was set in the white artifact area on the CT images (site A), in a slightly remote area from the white artifact (site B), and in a black artifact area (site C). A PET/CT scan was performed with and without the metal bridge at each simulated tumor site, and the artifactual influence was evaluated on the axial attenuation-corrected (AC) PET images, in which the simulated tumor produced the strongest accumulation. Measurements were performed using three types of PET/CT scanners (scanners 1 and 2 with CT-based attenuation correction, and 3 with Cesium-137 ( 137 Cs)-based attenuation correction). The influence of the metal bridge was evaluated using the change rate of the SUVmean with and without the metal bridge. At site A, an overestimation was shown (scanner 1: +5.0% and scanner 2: +2.5%), while scanner 3 showed an underestimation of -31.8%. At site B, an overestimation was shown (scanner 1: +2.1% and scanner 2: +2.0%), while scanner 3 showed an underestimation of -2.6%. However, at site C, an underestimation was shown (scanner 1: -25.0%, scanner 2: -32.4%, and scanner 3: -8.4%). When CT is used for attenuation correction in patients with dental metal prostheses, an underestimation of radioactivity of accumulated tracer is anticipated in the dark streak artifact area on the CT images. In this study, the dark streak artifacts of the CT

  18. Non-malignant FDG uptake in infradiaphragmatic adipose tissue: a new site of physiological tracer biodistribution characterised by PET/CT

    International Nuclear Information System (INIS)

    Bar-Shalom, Rachel; Keidar, Zohar; Gaitini, Diana; Israel, Ora

    2004-01-01

    The purpose of this study was to characterise a benign pattern of infradiaphragmatic 18 F-fluorodeoxyglucose (FDG) uptake in cancer patients using PET/CT. Infradiaphragmatic foci of FDG uptake, localised by PET/CT in regions of normal fat tissues, were demonstrated, in conjunction with fatty uptake in the neck and shoulders, in 9 of 1,241 (0.7%) patients. The imaging and clinical characteristics of this pattern and its possible clinical significance were assessed. PET/CT precisely localised infradiaphragmatic fat uptake (IDFU) within normal retroperitoneal fatty tissue of the perirenal space (nine patients) and in the paracolic or parahepatic space (four patients). Perirenal uptake was bilateral in five patients and focal in six. Paracolic and parahepatic uptake was bilateral in three patients and linear in all four patients. There was no evidence of malignancy at any of the sites during a follow-up period of 9-21 months. IDFU was significantly more prevalent in young patients assessed for monitoring response to therapy, and was always associated with the benign supradiaphragmatic uptake pattern, although its prevalence was significantly lower. There were no significant differences between the clinical characteristics of these two patterns of benign fatty FDG uptake. It is concluded that PET/CT allows for precise identification of increased FDG uptake in abdominal fatty tissue and further exclusion of disease at such sites. This benign uptake may represent increased glucose consumption in activated brown adipose tissue, similar to the mechanism suggested for supradiaphragmatic uptake. Recognition of this benign IDFU pattern is important for correct interpretation of abdominal PET findings in cancer patients. (orig.)

  19. Human serum albumin binding assay based on displacement of a non selective fluorescent inhibitor.

    Science.gov (United States)

    Thorarensen, Atli; Sarver, Ronald W; Tian, Fang; Ho, Andrea; Romero, Donna L; Marotti, Keith R

    2007-08-15

    In this paper, we describe a fluorescent antibacterial analog, 6, with utility as a competition probe to determine affinities of other antibacterial analogs for human serum albumin (HSA). Analog 6 bound to HSA with an affinity of 400+/-100 nM and the fluorescence was environmentally sensitive. With 370 nm excitation, environmental sensitivity was indicated by a quenching of the 530 nm emission when the probe bound to HSA. Displacement of dansylsarcosine from HSA by 6 indicated it competed with compounds that bound at site II (ibuprofen binding site) on HSA. Analog 6 also shifted the NMR peaks of an HSA bound oleic acid molecule that itself was affected by compounds that bound at site II. In addition to binding at site II, 6 interacted at site I (warfarin binding site) as indicated by displacement of dansylamide and the shifting of NMR peaks of an HSA bound oleic acid molecule affected by warfarin site binding. Additional evidence for multiple site interaction was discovered when a percentage of 6 could be displaced by either ibuprofen or phenylbutazone. A competition assay was established using 6 to determine relative affinities of other antibacterial inhibitors for HSA.

  20. Clinical values of CT and dynamic CT in brain infarction

    International Nuclear Information System (INIS)

    Lim, Soo Il; Jang, Do; Seo, Eun Joo; Sohn, Myung Hee; Choi, Ki Chul

    1985-01-01

    With the advent of faster scan time and new computer program, a scanning technique called 'dynamic computed tomography' has become possible. Dynamic computed tomography consisted of performing multiple rapid sequence scans after injection of contrast material. The authors have evaluated the clinical usefulness of computed tomography and dynamic computed tomography of 93 patients with brain infarction and/or ischemia during the period of 17 months from April 1983 to August 1984 in Department of Radiology, Chonbuk National University Hospital. The results were as follows; 1. The age distribution ranged from 18 years to 78 years. Among them the most common age group was between 50 years and 59 years (40.9%). 2. The sites of brain infarction were cerebral lobes (63 cases,68), basal ganglia (15 cases, 16.1%) and multiple sites (6 cases, 6.4%). The common affected site was middle cerebral artery territories. 3. The contrast enhancement of acute infarction was noted in 14 cases (17.5%) which occurred commonly between 3 days and 2 weeks from ictus. 4. The patterns of time-density curve in brain infarction and/or ischemia were as follow: a. Depression of slow wash-in phase was 20 cases (59%). b. Lower peak concentration was 17 cases (50%). c. Lower and delayed peak concentration was 7 cases (21%). d. No definite peak concentration was 6 cases (18%). First three patterns of time-density curve were thought as relatively characteristic curve of brain infarction and/or ischemia. 5. Two cases that showed negative findings on precontrast CT scan appeared to be positive findings as hypodensity on postcontrast CT scan and were confirmed as brain infarction by dynamic CT. 6. The diagnostic entity of dynamic CT scan were as follows; a. large artery thrombotic infarction were 23 cases (58%). b. lacnar infarction were 6 cases (15%). c. ischemia were 5 cases (13%). d. normal were 5 cases (13%). In six cases of lacunar infarction which was double hypodensity on pre-and postcontrast CT

  1. Clinical values of CT and dynamic CT in brain infarction

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Soo Il; Jang, Do; Seo, Eun Joo; Sohn, Myung Hee; Choi, Ki Chul [Chonbuk National University College of Medicine, Jeonju (Korea, Republic of)

    1985-04-15

    With the advent of faster scan time and new computer program, a scanning technique called 'dynamic computed tomography' has become possible. Dynamic computed tomography consisted of performing multiple rapid sequence scans after injection of contrast material. The authors have evaluated the clinical usefulness of computed tomography and dynamic computed tomography of 93 patients with brain infarction and/or ischemia during the period of 17 months from April 1983 to August 1984 in Department of Radiology, Chonbuk National University Hospital. The results were as follows; 1. The age distribution ranged from 18 years to 78 years. Among them the most common age group was between 50 years and 59 years (40.9%). 2. The sites of brain infarction were cerebral lobes (63 cases,68), basal ganglia (15 cases, 16.1%) and multiple sites (6 cases, 6.4%). The common affected site was middle cerebral artery territories. 3. The contrast enhancement of acute infarction was noted in 14 cases (17.5%) which occurred commonly between 3 days and 2 weeks from ictus. 4. The patterns of time-density curve in brain infarction and/or ischemia were as follow: a. Depression of slow wash-in phase was 20 cases (59%). b. Lower peak concentration was 17 cases (50%). c. Lower and delayed peak concentration was 7 cases (21%). d. No definite peak concentration was 6 cases (18%). First three patterns of time-density curve were thought as relatively characteristic curve of brain infarction and/or ischemia. 5. Two cases that showed negative findings on precontrast CT scan appeared to be positive findings as hypodensity on postcontrast CT scan and were confirmed as brain infarction by dynamic CT. 6. The diagnostic entity of dynamic CT scan were as follows; a. large artery thrombotic infarction were 23 cases (58%). b. lacnar infarction were 6 cases (15%). c. ischemia were 5 cases (13%). d. normal were 5 cases (13%). In six cases of lacunar infarction which was double hypodensity on pre

  2. Clinical study of 18F-FDG PET/CT whole-body imaging in disseminated carcinoma of unknown primary site

    International Nuclear Information System (INIS)

    Wang Guohui; Liang Peiyan; Cai Yanjun; Zhang Weiguang; Xie Chuanmiao; Wu Peihong

    2008-01-01

    Objective: Carcinoma of unknown primary (CUP) is not uncommon in usual clinical settings. They are, by definition, those cases with clinically suspected primary malignancy but not revealed by conventional investigation. The aim of this study was to investigate the efficacy of whole-body 18 F-fluoro- deoxyglucose (FDG) PET/CT in detecting a primary neoplasm for these patients. Methods: A totle of 150 patients with retrievable records from 169 CUP patients were selected within a group of consecutive 2589 patients from Jan. 2006 to Jun. 2007. All cases underwent whole-body FDG PET/CT scan. The final diagnoses were confirmed by pathologic results, other imaging modalities or clinical follow-up. Results: Among 150 patients, primary tumor sites were successfully detected by whole-body 18 F-FDG PET/CT scan in 70 cases (46.7%), of which 52 were pathologically confirmed and 18 by clinical follow-up. And 38 cases (54.3%) were lung cancer, 8 (11.4%) were nasopharyngeal carcinoma, 13 (18.6%) in digestive sys- tem, and 11 (15.7%) in other systems. Three clinically suspected CUP cases with negative 18 F-FDG PET/ CT were subsequently confirmed of benign processes by clinical follow-up. Six patients were wrongly diagnosed by 18 F-FDG PET/CT, and 15 patients did not have a confirmed diagnosis by the end of research. The primary cause of malignancy after 18 F-FDG PET/CT remained obscure in 56 patients, only 3 of whom be- came known during the course of clinical follow-up (nasopharyngeal bladder and esophageal carcinoma). Conclusion: 18 F-FDG PET/CT whole-body imaging plays an important role in patients with metastatic CUP. (authors)

  3. MicroCT analysis of calcium/phosphorus ratio maps at different bone sites

    International Nuclear Information System (INIS)

    Speller, R.; Pani, S.; Tzaphlidou, M.; Horrocks, J.

    2005-01-01

    The Ca/P ratio was measured in cortical bone samples from the femoral neck, front and rear tibia of rats, rabbits and lambs using synchrotron microCT. Use of a monoenergetic X-ray beam, as provided by the synchrotron facility, generates accurate 3-D maps of the linear attenuation coefficient within the sample and hence gives the ability to map different chemical components. Data were taken at 20keV for each bone sample and calibration phantoms. From the 3-D data sets, multiple 2-D slices were reconstructed with a slice thickness of ∼28μm and converted to Ca/P ratios using the calibration phantom results. Average values for each animal and bone site were estimated. Differences between the same bone sites from different animals are not significant (0.3 -3 ) demonstrating a dependence upon lifestyle and bone use. The spatial distribution of Ca/P was found to be non-uniform for some bones and some animals possibly indicating the structural mechanism for obtaining bone strength

  4. Walker Branch Throughfall Displacement Experiment Data Report: Site Characterization, System Performance, Weather, Species Composition, and Growth

    Energy Technology Data Exchange (ETDEWEB)

    Hanson, P.J.

    2001-09-04

    This numeric data package provides data sets, and accompanying documentation, on site characterization, system performance, weather, species composition, and growth for the Throughfall Displacement Experiment, which was established in the Walker Branch Watershed of East Tennessee to provide data on the responses of forests to altered precipitation regimes. The specific data sets include soil water content and potential, coarse fraction of the soil profile, litter layer temperature, soil temperature, monthly weather, daily weather, hourly weather, species composition of trees and saplings, mature tree and sapling annual growth, and relative leaf area index. Fortran and SAS{trademark} access codes are provided to read the ASCII data files. The data files and this documentation are available without charge on a variety of media and via the Internet from the Carbon Dioxide Information Analysis Center (CDIAC).

  5. CT of the acetabular fracture

    International Nuclear Information System (INIS)

    Magu, N.K.; Moda, S.K.; Magu, Sarita; Airon, R.K.

    1993-01-01

    Nine patients with 10 injured hips, in whom acetabular fractures with posterior dislocation of the femoral heads were demonstrated on initial radiography, underwent CT. CT was found superior in detecting the presence of intra-articular bony fragments in Group A patients (40%), where conventional radiography exhibited congruous manipulative reduction of the joint surfaces. The spatial position of the intra-articular fragments could not be ascertained on conventional radiography in 40% of the patients in Group B, in whom congruous manipulative reduction could not be achieved and subluxation of the femoral heads was observed. On conventional radiography, it was also difficult to appreciate the presence of intra-articular fragments in 60% of the patients in Group B, in whom either the dislocation could not be reduced (40%) or the femoral head redislocated after close manipulative reduction (20%). CT proved its superiority in detecting the extent of the fractures of the acetabular roof, posterior and anterior acetabular margins, the quadrilateral plate along with rotation of the acetabular columns and displacements of the major fractured fragments. Associated fractures of the sacrum (20%), and traumatic lesions of the sacro-iliac joint (20%), not apparent on conventional radiography were well demonstrated by CT. As a result of CT, the treatment was changed in 60% of the patients in Group A, and 40% in Group B. In addition, CT permitted a better choice of surgical technique in the management of acetabular fractures. (author). 9 refs., 3 figs., 2 tabs

  6. Respiratory compensation in projection imaging using a magnification and displacement model

    International Nuclear Information System (INIS)

    Crawford, C.R.; King, K.F.; Ritchie, C.J.; Godwin, J.D.

    1996-01-01

    Respiratory motion during the collection of computed tomography (CT) projections generates structured artifacts and a loss of resolution that can render the scans unusable. This motion is problematic in scans of those patients who cannot suspend respiration, such as the very young or incubated patients. In this paper, the authors present an algorithm that can be used to reduce motion artifacts in CT scans caused by respiration. An approximate model for the effect of respiration is that the object cross section under interrogation experiences time-varying magnification and displacement along two axes. Using this model an exact filtered backprojection algorithm is derived for the case of parallel projections. The result is extended to generate an approximate reconstruction formula for fan-beam projections. Computer simulations and scans of phantoms on a commercial CT scanner validate the new reconstruction algorithms for parallel and fan-beam projections. Significant reduction in respiratory artifacts is demonstrated clinically when the motion model is satisfied. The method can be applied to projection data used in CT single photon emission computed tomography (SPECT), positron emission tomography (PET), and magnetic resonance imaging (MRI)

  7. A comparison of the value of MRI and CT in patients with Nelson syndrome

    International Nuclear Information System (INIS)

    Kersjes, W.; Allmendinger, S.; Christ, F.; Stiebler, H.; Bockisch, A.; Klingmueller, D.

    1992-01-01

    The hypophyses of 13 patients with Nelson syndrome following bilateral adrenalectomy were examined by MRI and CT. Diffuse enlargement of the hypophysis was demonstrated in 8 patients by CT and in 9 by MRI. Compared with CT, MRI provides better demonstration of tumour development, such as abnormal convexity of the cranial margin of the hypophysis (MRI 4/13, CT 1/13), displacement of the infundibulum (MRI 4/13, CT 0/13) or optic chiasm (MRI 2/13, CT 0/13). MRI also provides diagnostically important differentiation between scar tissue and recurrence of tumour following hypophysectomy (MRI 1/3, CT 0/3) and more accurate demonstration of infiltration of the cavernous sinus (MRI 4/13, CT 2/13). CT is superior only in showing the floor of the sella. MRI is the method of choice for imaging in cases of Nelson syndrome. (orig.) [de

  8. Effect of reverse cyclic loading on the fracture resistance curve in C(T) specimen

    International Nuclear Information System (INIS)

    Sung Seok, C.; Jin Kim, Y.; Il Weon, J.

    1999-01-01

    Fracture resistance (J-R) curves, which are used for elastic-plastic fracture mechanics analyses, are known to be dependent on the cyclic loading history. The objective of this paper is to investigate the effect of reverse cyclic loading on the J-R curves in C(T) specimens. The effect of two parameters was observed on the J-R curves during the reverse cyclic loading. One was the minimum-to-maximum load ratio (R) and the other was the incremental plastic displacement (δ cycle /δ i ), which is related to the amount of crack growth that occurs in a cycle. Fracture resistance tests on C(T) specimens with varying the load ratio and the incremental plastic displacement were performed, and the test results showed that the J-R curves were decreased with decreasing the load ratio and decreasing the incremental plastic displacement. Direct current potential drop (DCPD) method was used for the detection of crack initiation and crack growth in typical laboratory J-R tests. The values of crack initiation J-integral (J I ) and crack initiation displacement (δ i ) were also obtained by using the DCPD method. (orig.)

  9. Displaced Sense: Displacement, Religion and Sense-making

    OpenAIRE

    Naidu, Maheshvari

    2016-01-01

    Whether formally categorized as refugees or not, displaced migrants experience varying degrees of vulnerability in relation to where they find themselves displaced. The internally displaced furthermore squat invisibly and outside the boundaries of the legal framework and incentive structures accorded to those classified as 'refugee'. They are thus arguably, by and large, left to source sustaining solutions for themselves. This article works through the theoretical prism of sense-making theory...

  10. The reliability of cone-beam computed tomography to assess bone density at dental implant recipient sites: a histomorphometric analysis by micro-CT.

    Science.gov (United States)

    González-García, Raúl; Monje, Florencio

    2013-08-01

    The aim of this study was to objectively assess the reliability of the cone-beam computed tomography (CBCT) as a tool to pre-operatively determine radiographic bone density (RBD) by the density values provided by the system, analyzing its relationship with histomorphometric bone density expressed as bone volumetric fraction (BV/TV) assessed by micro-CT of bone biopsies at the site of insertion of dental implants in the maxillary bones. Thirty-nine bone biopsies of the maxillary bones at the sites of 39 dental implants from 31 edentulous healthy patients were analyzed. The NobelGuide™ software was used for implant planning, which also allowed fabrication of individual stereolithographic surgical guides. The analysis of CBCT images allowed pre-operative determination of mean density values of implant recipient sites along the major axis of the planned implants (axial RBD). Stereolithographic surgical guides were used to guide implant insertion and also to extract cylindrical bone biopsies from the core of the exact implant site. Further analysis of several osseous micro-structural variables including BV/TV was performed by micro-CT of the extracted bone biopsies. Mean axial RBD was 478 ± 212 (range: 144-953). A statistically significant difference (P = 0.02) was observed among density values of the cortical bone of the upper maxilla and mandible. A high positive Pearson's correlation coefficient (r = 0.858, P micro-CT at the site of dental implants in the maxillary bones. Pre-operative estimation of density values by CBCT is a reliable tool to objectively determine bone density. © 2012 John Wiley & Sons A/S.

  11. Bone quality evaluation at dental implant site using multislice CT, micro-CT, and cone beam CT

    NARCIS (Netherlands)

    Parsa, A.; Ibrahim, N.; Hassan, B.; van der Stelt, P.; Wismeijer, D.

    2015-01-01

    Objectives The first purpose of this study was to analyze the correlation between bone volume fraction (BV/TV) and calibrated radiographic bone density Hounsfield units (HU) in human jaws, derived from micro-CT and multislice computed tomography (MSCT), respectively. The second aim was to assess the

  12. Spring constant measurement using a MEMS force and displacement sensor utilizing paralleled piezoresistive cantilevers

    Science.gov (United States)

    Kohyama, Sumihiro; Takahashi, Hidetoshi; Yoshida, Satoru; Onoe, Hiroaki; Hirayama-Shoji, Kayoko; Tsukagoshi, Takuya; Takahata, Tomoyuki; Shimoyama, Isao

    2018-04-01

    This paper reports on a method to measure a spring constant on site using a micro electro mechanical systems (MEMS) force and displacement sensor. The proposed sensor consists of a force-sensing cantilever and a displacement-sensing cantilever. Each cantilever is composed of two beams with a piezoresistor on the sidewall for measuring the in-plane lateral directional force and displacement. The force resolution and displacement resolution of the fabricated sensor were less than 0.8 µN and 0.1 µm, respectively. We measured the spring constants of two types of hydrogel microparticles to demonstrate the effectiveness of the proposed sensor, with values of approximately 4.3 N m-1 and 15.1 N m-1 obtained. The results indicated that the proposed sensor is effective for on-site spring constant measurement.

  13. An ion displacement membrame model.

    Science.gov (United States)

    Hladky, S B; Harris, J D

    1967-09-01

    The usual assumption in treating the diffusion of ions in an electric field has been that the movement of each ion is independent of the movement of the others. The resulting equation for diffusion by a succession of spontaneous jumps has been well stated by Parlin and Eyring. This paper will consider one simple case in which a different assumption is reasonable. Diffusion of monovalent positive ions is considered as a series of jumps from one fixed negative site to another. The sites are assumed to be full (electrical neutrality). Interaction occurs by the displacement of one ion by another. An ion leaves a site if and only if another ion, not necessarily of the same species, attempts to occupy the same site. Flux ratios and net fluxes are given as functions of the electrical potential, concentration ratios, and number of sites encountered in crossing the membrane. Quantitative comparisons with observations of Hodgkin and Keynes are presented.

  14. A Symptomatic Displaced Os Odontoideum: A Case Report

    Directory of Open Access Journals (Sweden)

    Farshad Nikouei

    2016-05-01

    Full Text Available Introduction Os odontoideum (OO is a form of odontoid anomaly presented by a separate ossicle with a smooth, sclerotic border not fused with C2 body. The current paper reports a boy with irreducible displaced os odontoideum with severe neurologic deficit after a minor trauma. Case Presentation A 16-year-old boy admitted in the center due to neck pain and torticollis with neurologic deficit. He had a history of multiple minor traumas. Advanced imaging assessment demonstrated displaced os odontoideum with minimal space available for cord (SAC and myelomalacia. After unsuccessful closed reduction a 2-stage operation was planned: first, the anterior transoral release and odontoid resection with subsequent halo-traction and second, the posterior atlanto-axial instrumented fusion with bilateral C1 hook and C2 pedicular screws. Conclusions Congenital anomalies of the odontoid are associated with C1-C2 instability that can be subluxated or dislocated with minor trauma and cause permanent neurologic deficit or even death. When acute cervical spine trauma is imaged, os odontoideum should be distinguished from an acute dens fracture with a multimodality imaging approach including computed tomography (CT, magnetic resonance imaging (MRI and radiography. Here is the report of a rare case with irreducible displaced os odontiodeum treated him with anterior release, odontoid resection and posterior C1-C2 instrumented fusion.

  15. Radiation displacement damage estimates for a radionuclide waste stabilization material

    International Nuclear Information System (INIS)

    Dolan, K.W.

    1977-01-01

    Estimates of the number of atomic displacements produced in pollucite by the radioactive decay of Cs-134 are made. Pollucite is a candidate material for radionuclide waste stabilization, while Cs-134 is one of the radionuclide products which would be chemically bound in the pollucite lattice. At the maximum concentration of Cs-134 in pollucite, assuming a threshold displacement energy of 15.0 eV, the displacement rate is estimated to be 4.3 x 10 12 atoms/cm 3 /second which includes all atomic species in the pollucite lattice. It was found that most of the displacements, 85 percent, were caused by elastic scattering of photoelectrons and Compton electrons which are products of γ-ray interactions in the material. Most of the remaining displacements are caused by elastic scattering of β-particles. Recoil energies of the Ba daughter product are insufficient to cause displacement. Atomic displacements of nearest neighbors, atoms within one lattice spacing of the decay site, are estimated to be 2.7 x 10 6 atoms/cm 3 /second. These estimates provide a starting point for assessing the long term stability of pollucite to radiation damage

  16. Neuroleptics and β-carbolines displace (3H)imipramine from its binding sites in human and rat tissues

    International Nuclear Information System (INIS)

    Rommelspacher, H.; Strauss, S.

    1985-01-01

    Most investigations dealing with the pharmacological characterization of ( 3 H)imipramine binding sites focus on tricyclic antidepressants (TCA). This approach seemed to be justified since imipramine belongs to that chemical group. Langer and coworkers, however, introduced a tetrahydro-β-carboline (THβC) as a possible endogenous ligand. Thus, the high affinity of imipramine towards the binding sites might not be due to its special chemical structure but due to its tricyclic nature. In the present paper the structure-activity-relationships of neuroleptics and β-carbolines were investigated and compared with that of tricyclic antidepressants. Among the tricyclic neuroleptics those with an electron attracting substituent (-Cl) exerted highest affinity. The effect was attenuated by a long, cyclic side chain. The affinity of tricyclic neuroleptics was only slightly weaker than that of 6-Meo-THβC the suggested endogenous ligand. The experiments with other THβCs supported the observation that an electron attracting substituent increases the affinity of a compound to the ( 3 H)imipramine binding sites. Comparison of the binding characteristics of ( 3 H)imipramine to membranes of human brain and thrombocytes as well as those of rat brain and thrombocytes revealed no differences among both species. Furthermore, the displacing potencies of neuroleptics were very similar with only slightly more activity in human tissue. As a methodological aspect the applicability of the 'Lowry' method to determine the protein concentration is discussed. (Author)

  17. Case report: PET/CT, a cautionary tale

    International Nuclear Information System (INIS)

    Wang, Jayson; Cook, Gary; Frank, John; Dina, Roberto; Livni, Naomi; Lynn, John; Fleming, William; Seckl, Michael J

    2007-01-01

    The use of combined positron emission tomography/computerised tomography (PET/CT) scanners in oncology has been shown to improve the staging of tumours and the detection of relapses. However, mis-registration errors are increasingly recognised to be a common pitfall of PET/CT studies. We report a patient with a germ cell tumour of the testis, who underwent a PET/CT scan to detect the site of relapse with a view to surgical removal. However, the PET/CT scan mislocalised the tumour site to be within the T2 vertebral body. A subsequent endoscopic ultrasound scan however showed the tumour to be anterior to the vertebral body, which was confirmed at surgery. In this report, we highlight the artefactual mislocalisation errors which may occur with PET/CT imaging, and the need to review and verify these scans

  18. Clinical value of 64-slice spiral CT for classification of femoral neck fracture

    International Nuclear Information System (INIS)

    Zhu Jiangtao; Gong Jianping; Cai Wu; Zhu Jianbing; Chen Guangqiang; Qian Minghui

    2011-01-01

    Objective: To evaluate the clinical application of 64-slice spiral CT for classification of femoral neck fracture. Methods: The survey was comprised of 46 patients with femoral neck fractures detected with plain radiographs and CT images. Cases were randomly presented in 2 formats: plain radiographs and CT. Garden classification was queried. Modification of garden classification (nondisplaced vs displaced) was taken to compare with plain radiographs and CT in the study. Results: The results of classification for plain radiographs were 2 cases of Garden Ⅰ, 10 cases of Ⅱ, 22 cases of Ⅲ, and 12 cases of Ⅳ. Those for CT were 1 cases of Garden Ⅰ, 4 cases of Ⅱ, 26 cases of Ⅲ, and 15 cases of Ⅳ. CT improved the accuracy of Garden Classification (P<0.05). Conclusion: Garden classification using CT images shows good conformation with results of surgery. 64-Slic CT is better plain radiographs for Garden classification of femoral neck fracture. (authors)

  19. Comparison of CT and MRI in patients with tibial plateau fracture: can CT findings predict ligament tear or meniscal injury?

    International Nuclear Information System (INIS)

    Mui, Leonora W.; Engelsohn, Eliyahu; Umans, Hilary

    2007-01-01

    (1) To determine the accuracy of computed tomography (CT) in the evaluation of ligament tear and avulsion in patients with tibial plateau fracture. (2) To evaluate whether the presence or severity of fracture gap and articular depression can predict meniscal injury. A fellowship-trained musculoskeletal radiologist retrospectively reviewed knee CT and MRI examinations of 41 consecutive patients presenting to a level 1 trauma center with tibial plateau fractures. Fracture gap, articular depression, ligament tear and footprint avulsions were assessed on CT examinations. The MRI studies were examined for osseous and soft tissue injuries, including meniscal tear, meniscal displacement, ligament tear, and ligament avulsion. CT demonstrated torn ligaments with 80% sensitivity and 98% specificity. Only 2% of ligaments deemed intact on careful CT evaluation had partial or complete tears on MRI. Although the degree of fracture gap and articular depression was significantly greater in patients with meniscal injury compared with those without meniscal injury, ROC analysis demonstrated no clear threshold for gap or depression that yielded a combination of high sensitivity and specificity. In the acute setting, CT offers high sensitivity and specificity for depicting osseous avulsions, as well as high negative predictive value for excluding ligament injury. However, MRI remains necessary for the preoperative detection of meniscal injury. (orig.)

  20. Evaluation of multi-modality CT-MRI-SPECT registration tools for radiotherapy treatment planning purposes

    International Nuclear Information System (INIS)

    Bianchini, S.; Alfonso, R.; Castillo, J.; Coca, M.; Torres, L.

    2013-01-01

    A qualitative and quantitative comparison of registration CT-CT, CT-MR and CT-SPECT performed by the different software and algorithms studies is presented. Only two studied software were full DICOM RT compatible while accepting DICOM images in any layout. Quantitative results of fiducial displacement errors were calculated for all software and available registration methods. The presented methodology demonstrated being effective for assessing the quality of studied image registration tools in the radiotherapy planning context, provided the images are free of significant geometric deformation. When implementing this methodology in real patients, the use of immobilization devices, such as thermoplastic masks, is recommended for enhanced quality of image registration. (Author)

  1. CT findings of exophageal perforation

    Energy Technology Data Exchange (ETDEWEB)

    Heo, Jeong Nam; Choi, Yo Won; Jeon, Seok Chol; Park, Choong Ki; Hahm, Chang Kok [Hanyang University College of Medicine, Seoul (Korea, Republic of)

    2002-09-01

    To determine which CT findings are useful for the early disgnosis of esophageal perforation, and on the basis of these findings, to assess the accuracy of prediction of the perforation site. A review of medical records indicated that between January 1995 and December 2001, 36 patients with esophageal perforation were admitted to our hospital. Thirteen of these [M:F=8:5, age; 28-69 (mean, 52.4) years], who had undergone CT chest scanning, were included in this study. The causes of esophageal perforation were trauma (n=5), infectious diseases (n=4), Boerhaave syndrome (n=1), lung cancer (n=1), esophageal cancer (n=1), and idiopathic. Two chest radiologists unaware of the clinical findings reviewed the CT scans and predicted whether the upper or lower esophagus was perforated. The most common CT finding was extraluminal air at the posterior mediastinum (n=11), while other findings included pulmonary consolidation (n=10), pleural effusion (n=7), discontinuity of the esophageal wall (n=6) and subcutaneous emphysema (n=4), fluid collection around the esophagus (n-4), esophageal wall thickening (n=4), pneumothorax (n=2), and lung abscess (n=2). The perforation site was accurately predicted in 76.9% of cases (10/13). The CT findings which help the diagnosis of esophageal perforation, and prediction of the sites at which it occurs, are extraluminal air of fluid collection, focal defect of the esophageal wall, and esophageal wall thickening.

  2. CT findings of exophageal perforation

    International Nuclear Information System (INIS)

    Heo, Jeong Nam; Choi, Yo Won; Jeon, Seok Chol; Park, Choong Ki; Hahm, Chang Kok

    2002-01-01

    To determine which CT findings are useful for the early disgnosis of esophageal perforation, and on the basis of these findings, to assess the accuracy of prediction of the perforation site. A review of medical records indicated that between January 1995 and December 2001, 36 patients with esophageal perforation were admitted to our hospital. Thirteen of these [M:F=8:5, age; 28-69 (mean, 52.4) years], who had undergone CT chest scanning, were included in this study. The causes of esophageal perforation were trauma (n=5), infectious diseases (n=4), Boerhaave syndrome (n=1), lung cancer (n=1), esophageal cancer (n=1), and idiopathic. Two chest radiologists unaware of the clinical findings reviewed the CT scans and predicted whether the upper or lower esophagus was perforated. The most common CT finding was extraluminal air at the posterior mediastinum (n=11), while other findings included pulmonary consolidation (n=10), pleural effusion (n=7), discontinuity of the esophageal wall (n=6) and subcutaneous emphysema (n=4), fluid collection around the esophagus (n-4), esophageal wall thickening (n=4), pneumothorax (n=2), and lung abscess (n=2). The perforation site was accurately predicted in 76.9% of cases (10/13). The CT findings which help the diagnosis of esophageal perforation, and prediction of the sites at which it occurs, are extraluminal air of fluid collection, focal defect of the esophageal wall, and esophageal wall thickening

  3. Diagnostic value of multiplanar reconstruction in CT recognition of lumbar spinal disorders

    International Nuclear Information System (INIS)

    Im, S. K.; Choi, J. H.; Kim, C. H.; Sohn, M. H.; Lim, K. Y.; Choi, K. C.

    1984-01-01

    The computer tomography is useful in evaluation of bony structures and adjacent soft tissues of the lumbar spine. Recently, the multiplanar reconstruction of lumbar spine of CT of significant value for the anatomical localization and for the myelographic and surgical correlation. We observed 177 cases of lumbar spine CT, who complains of spinal symptom, during the period from Dec. 1982 to Aug. 1984. The results were as follows: 1. The sex distribution of cases were 113 males and 44 females. The CT diagnosis showed 152 cases of herniated lumbar disc, 15 cases of degenerative disease, 5 cases of spine tbc., 3 cases of spine trauma and 2 cases of meningocele. 2. CT findings of herniated disc were as follows: focal protrusion of posterior disc margin and obliteration of anterior epidural fat in all cases, indentation on dural sac in 92 cases (60.5%) soft tissue mass in epidural fat in 85 cases (55.9%), compression or displacement of nerve root sheath in 22 cases(14.4%). 3. Sites of herniated lumbar disc were at L4-L5 level in 100 cases(59.1%) and at L5-S1 level in 65 cases (38.4%). Location of it were central type in 70 cases(41.1%), left-central type in 46 cases (27.2%), right-central type in 44 cases(26.0%) and lateral type in 9 cases (5.1%). 4. The sagittal reconstruction images were helpful in evaluating neural foramina, size of disc bluge into spinal canal, especially at L5-S1, and patients with spondylolisthesis. The coronal reconstruction images were the least informative, although they contributed to the evaluation of lumbar nerve roots of course, the axial CT scans were the most sensitive and specific.

  4. CT findings in epileptic children

    International Nuclear Information System (INIS)

    Koide, Nobuo; Kimura, Shigeru; Watanabe, Jun; Haneda, Satoshi; Takebe, Yukinao

    1981-01-01

    CT findings in 43 children with generalized seizures (grand mal seizures) (GM group) and in 50 children with partial seizures (P group), classified according to clinical seizure type, were studied. 1) CT abnormalities were demonstrated in 19% (8/43) in GM group and in 40% (20/50) in P group, including localized CT abnormalities in 9.3% (4/43) and in 34% (17/50) respectively. CT abnormalities were found more frequently in cases with abnormal past histories and/or mental defects (MD) than in those without them. 2) In P group, localized CT abnormalities and generalized brain atrophy were observed in 13 and 7 cases respectively. In 40 cases with focal epileptic discharges (FED) in EEG, localized CT abnormalities were demonstrated in 23% (9/40). The sites of localized CT abnormalities corresponded in 73% (11/15) to the sites of focal suppression in EEG (i.e., slowing, low amplitude and lazy pattern) regardless of FED. 3) The bicaudate cerebro-ventricular index (B-CVI) in 19 cases in the normal control group over 2 years of age was 10.0 +- 1.2 (mean +- SD). Ventricular narrowing (VN), with B-CVI less than 8.2 (mean - 1.5 SD), was observed in 5, 17 and 27% in control, GM and P groups respectively, indicating more frequently in epileptic children than in normal controls. Seizures were well controlled in 85% (11/13) in VN group and in 70% (26/36) in normal ventricular group. Brain atrophy in CT findings to inspection was ascertained in all cases by measuring B-CVI. (author)

  5. Heritability estimates on resting state fMRI data using ENIGMA analysis pipeline.

    Science.gov (United States)

    Adhikari, Bhim M; Jahanshad, Neda; Shukla, Dinesh; Glahn, David C; Blangero, John; Reynolds, Richard C; Cox, Robert W; Fieremans, Els; Veraart, Jelle; Novikov, Dmitry S; Nichols, Thomas E; Hong, L Elliot; Thompson, Paul M; Kochunov, Peter

    2018-01-01

    Big data initiatives such as the Enhancing NeuroImaging Genetics through Meta-Analysis consortium (ENIGMA), combine data collected by independent studies worldwide to achieve more generalizable estimates of effect sizes and more reliable and reproducible outcomes. Such efforts require harmonized image analyses protocols to extract phenotypes consistently. This harmonization is particularly challenging for resting state fMRI due to the wide variability of acquisition protocols and scanner platforms; this leads to site-to-site variance in quality, resolution and temporal signal-to-noise ratio (tSNR). An effective harmonization should provide optimal measures for data of different qualities. We developed a multi-site rsfMRI analysis pipeline to allow research groups around the world to process rsfMRI scans in a harmonized way, to extract consistent and quantitative measurements of connectivity and to perform coordinated statistical tests. We used the single-modality ENIGMA rsfMRI preprocessing pipeline based on modelfree Marchenko-Pastur PCA based denoising to verify and replicate resting state network heritability estimates. We analyzed two independent cohorts, GOBS (Genetics of Brain Structure) and HCP (the Human Connectome Project), which collected data using conventional and connectomics oriented fMRI protocols, respectively. We used seed-based connectivity and dual-regression approaches to show that the rsfMRI signal is consistently heritable across twenty major functional network measures. Heritability values of 20-40% were observed across both cohorts.

  6. Frequency of cerebral infarction secondary to head injury and the underlying mechanisms: CT study

    International Nuclear Information System (INIS)

    Fernande-Fresno, L.; Manzanares, R.; Caniego, J.L.; Velasco, M.; Parra, M.L.; Monasterio, F.

    1997-01-01

    To study the frequency of and possible mechanisms producing severe head injury (HI) by serial CT studies. We reviewed brain CT results in 154 HI patients examined over the past 31 months. All of them were hospitalized in the Intensive Care Unit (ICU) presenting coma with Glosgow Coma Scale scores of 9 or under. A first CT scan was performed when the patients arrived in the emergency room and at a least one more was carried out over the following 1 to 6 days. Sixteen of the 154 patients presented ischemic areas of low attenuation in a territory of defined vascular distribution that did not exist in the CT done at admission; the majority of them also had extensive extraaxial or intraaxial hematomas causing a considerable mass effect and cerebral displacement inducing different types of herniation. The vascular territories involved were anterior cerebral artery in five cases, middle cerebral artery in two, posterior cerebral artery in seven lenticulostriate arteries in six, anterior choroidal artery in five, perforating thalamus in six, recurrent artery in one case and superior cerebellar artery in another. In our series, there was a high prevalence (10.4%) of infarcts associated with severe HI; the most common etiopathogenic mechanisms are cerebral displacement accompanied by compression and vessel strain. (Author) 13 refs

  7. Displacement Parameter Inversion for a Novel Electromagnetic Underground Displacement Sensor

    Directory of Open Access Journals (Sweden)

    Nanying Shentu

    2014-05-01

    Full Text Available Underground displacement monitoring is an effective method to explore deep into rock and soil masses for execution of subsurface displacement measurements. It is not only an important means of geological hazards prediction and forecasting, but also a forefront, hot and sophisticated subject in current geological disaster monitoring. In previous research, the authors had designed a novel electromagnetic underground horizontal displacement sensor (called the H-type sensor by combining basic electromagnetic induction principles with modern sensing techniques and established a mutual voltage measurement theoretical model called the Equation-based Equivalent Loop Approach (EELA. Based on that work, this paper presents an underground displacement inversion approach named “EELA forward modeling-approximate inversion method”. Combining the EELA forward simulation approach with the approximate optimization inversion theory, it can deduce the underground horizontal displacement through parameter inversion of the H-type sensor. Comprehensive and comparative studies have been conducted between the experimentally measured and theoretically inversed values of horizontal displacement under counterpart conditions. The results show when the measured horizontal displacements are in the 0–100 mm range, the horizontal displacement inversion discrepancy is generally tested to be less than 3 mm under varied tilt angles and initial axial distances conditions, which indicates that our proposed parameter inversion method can predict underground horizontal displacement measurements effectively and robustly for the H-type sensor and the technique is applicable for practical geo-engineering applications.

  8. CT-based liver volumetry in a porcine model: impact on clinical volumetry prior to living donated liver transplantation

    International Nuclear Information System (INIS)

    Frericks, B.B.J.; Kiene, T.; Stamm, G.; Shin, H.; Galanski, M.

    2004-01-01

    Purpose: Exact preoperative determination of the liver volume is of great importance prior to hepatobiliary surgery, especially in living donated liver transplantation (LDLT). In the current literature, a strong correlation between preoperatively calculated and intraoperatively measured liver volumes has been described. Such accuracy seems questionable, primarily due to a difference in the perfusion state of the liver in situ versus after explantation. Purpose of the study was to asses the influence of the perfusion state on liver volume and the validity of the preoperative liver volumetry prior to LDLT. Methods: In an experimental study, 20 porcine livers were examined. The livers were weighted and their volumes were determined by water displacement prior and after fluid infusion to achieve a pressure physiologically found in the liver veins. The liver volumes in the different perfusion states were calculated based on CT-data. The calculated values were compared with the volume measured by water displacement and the weight of the livers. Results: Assessment of calculated CT volumes and water displacements at identical perfusion states showed a tight correlation and differed on average by 4 ± 5%. However, livers before and after fluid infusion showed a 33 ± 8% (350 ± 150 ml) difference in volume. Conclusion: CT-volumetry acquires highly accurate data as confirmed by water displacement studies. However, the perfusion state has major impact on liver volume, which has to be accounted for in clinical use. (orig.) [de

  9. Estimation of the displacement of cardiac substructures and the motion of the coronary arteries using electrocardiographic gating

    Directory of Open Access Journals (Sweden)

    Tan W

    2013-09-01

    Full Text Available Wenyong Tan,1,* Liying Xu,2,* Xiaohong Wang,1 Dasheng Qiu,3 Guang Han,1 Desheng Hu1 1Department of Radiation Oncology, Hubei Cancer Hospital, Wuhan, People’s Republic of China; 2Department of Radiology, Zhongnan Hospital, Wuhan University, Wuhan, People’s Republic of China; 3PET-CT Center, Hubei Cancer Hospital, Wuhan, People’s Republic of China *These authors have contributed equally to this paper Purpose: The aim of this study was to quantify the displacement of cardiac substructures, including the anterior myocardial territory (AMT, left ventricle, and coronary arteries during a normal cardiac cycle. Materials and methods: Computed tomography (CT images with retrospective electrocardiographic gating of 17 eligible patients were obtained. All images were reconstructed automatically for the end-diastolic and end-systolic phases. CT scanning without contrast at a random phase and a selected vertebral body were used as references to measure three-dimensionaldisplacements of the cardiac substructures. Results: The displacement between the end-diastolic and end-systolic phases (Dd-s was greater than that between the end-systolic and random phases and between the end-diastolic and random cardiac phases. The largest displacements for the heart were in the left, posterior, and inferior directions with an average Dd-s of approximately 4–6 mm. The average Dd-s for the AMT and left ventricle was 1.2–2.7 mm in the anterior and right directions, 4.3–7.8 mm in left and posterior directions, and 4.9–6.3 mm in superior and inferior directions. For the coronary arteries, the average Dd-s was 2.8–5.9 mm in the anterior-posterior direction, 3.5–6.6 mm in left-right direction, and 3.8–5.3 mm in the superior-inferior direction. Inter-observer agreement was excellent for the heart, AMT, and left ventricle (kappa coefficient, >0.75 for all and good for most coronary arteries in three dimensions (kappa coefficient, 0.511–0.687. The Dd-s did not

  10. The added value of 68Ga-DOTA-TATE-PET to contrast-enhanced CT for primary site detection in CUP of neuroendocrine origin.

    Science.gov (United States)

    Kazmierczak, Philipp M; Rominger, Axel; Wenter, Vera; Spitzweg, Christine; Auernhammer, Christoph; Angele, Martin K; Rist, Carsten; Cyran, Clemens C

    2017-04-01

    To quantify the additional value of 68 Ga-DOTA-TATE PET/CT in comparison with contrast-enhanced CT alone for primary tumour detection in neuroendocrine cancer of unknown primary (CUP-NET). In total, 38 consecutive patients (27 men, 11 women; mean age 62 years) with histologically proven CUP-NET who underwent a contrast-enhanced 68 Ga-DOTA-TATE PET/CT scan for primary tumour detection and staging between 2010 and 2014 were included in this IRB-approved retrospective study. Two blinded readers independently analysed the contrast-enhanced CT and 68 Ga-DOTA-TATE PET datasets separately and noted from which modality they suspected a primary tumour. Consensus was reached if the results were divergent. Postoperative histopathology (24 patients) and follow-up 68 Ga-DOTA-TATE PET/CT imaging (14 patients) served as the reference standards and statistical measures of diagnostic accuracy were calculated accordingly. The majority of confirmed primary tumours were located in the abdomen (ileum in 19 patients, pancreas in 12, lung in 2, small pelvis in 1). High interobserver agreement was noted regarding the suspected primary tumour site (Cohen's k 0.90, p DOTA-TATE PET demonstrated a significantly higher sensitivity (94 % vs. 63 %, p = 0.005) and a significantly higher accuracy (87 % vs. 68 %, p = 0.003) than contrast-enhanced CT. Ga-DOTA-TATE PET/CT compared with contrast-enhanced CT alone provides an improvement in sensitivity of 50 % and an improvement in accuracy of 30 % in primary tumour detection in CUP-NET. • 68 Ga-DOTA-TATE PET augments the sensitivity of contrast-enhanced CT by 50 % • 68 Ga-DOTA-TATE PET augments the accuracy of contrast-enhanced CT by 30 % • Somatostatin receptor-targeted hybrid imaging optimizes primary tumour detection in CUP-NET.

  11. [POKING REDUCTION TREATMENT OF DISPLACED SCAPULAR NECK FRACTURE WITH SHOULDER ARTHROSCOPY-ASSISTED SURGERY].

    Science.gov (United States)

    Qu, Feng; Yuan, Bangtuo; Qi, Wei; Wang, Junliang; Shen, Xuezhen; Wang, Jiangtao; Zhao, Gang; Liu, Yujie

    2014-07-01

    To discuss the effectiveness of Poking reduction with shoulder arthroscopy-assisted surgery for displaced scapular neck fracture. Between January 2009 and January 2012, 9 cases of displaced scapular neck fracture underwent shoulder arthroscopy-assisted surgery for Poking reduction treatment. Of 9 cases, 6 were men, and 3 were women, aged 21-54 years (mean, 39 years). The causes were traffic accident injury in 7 cases, falling injury from height in 1 case, and hurt injury in 1 case. The shoulder abduction, flexion, and external rotation were obviously limited. X-ray films showed all cases had obvious displaced scapular neck fracture. Three-dimensional reconstruction of CT showed a grossly displaced of fracture. The time of injury to surgery was 4-27 days (mean, 11 days). Patients obtained healing of incision by first intension, without infection, neurovascular injury, or other surgery-related complications. All patients were followed up 19- 31 months (mean, 23 months). X-ray films showed scapular neck fractures healed from 7 to 11 weeks (mean, 8 weeks). At last follow-up, the shoulder abduction, flexion, and external rotation activity were improved significantly when compared with ones at preoperation (P shoulder Constant score, American Shoulder and Elbow Surgenos (ASES) score, and Rowe score were significantly better than preoperative scores (P shoulder stability and reduce complications.

  12. CT of peroneal tendon injury in patients with calcaneal fractures

    International Nuclear Information System (INIS)

    Rosenberg, Z.S.; Feldman, F.; Singson, R.D.

    1986-01-01

    Injury to the peroneal tendons is a major complication of intraarticular calcaneal fractures. Heretofore, the injury has been difficult to diagnose by routine imaging modalities. However, CT studies of 24 intraarticular calcaneal fractures revealed evidence of peroneal tendon injury in 22 cases. The pathologic conditions included lateral displacement, subluxation, dislocation, and impingement on the tendons by bony fragments, hematomas, and scar tissue. Patients studied 6-12 months after injury had CT evidence consistent with clinical symptoms of peroneal tenosynovitis. Since peroneal tendon injury is surgically correctable, it should be differentiated from other known and more obvious complications, of calcaneal fractures. CT therefore serves as a valuable, noninvasive tool in evaluating these otherwise nonvisualized soft tissue structures in the immediate posttraumatic period as well as during long-term follow up

  13. Quantitative study on lung volume and lung perfusion using SPECT and CT in thoracal tumors

    International Nuclear Information System (INIS)

    Beyer-Enke, S.A.; Goerich, J.; Strauss, L.G.

    1988-01-01

    22 patients with space occupying lesions in the thoracal region were investigated by computer tomography and by perfusion scintigraphy using SPECT. In order to evaluate the CT images quantitatively, the lung volume was determined using approximation method and compared with the perfusion in the SPECT study. For this, anatomically equivalent transaxial SPECT slices had been coordinated to the CT slices. Between the determined lung volumes and the activity in the ocrresponding layers, a statistically significant correlation was found. It could be shown that the stronger perfusion, frequently observed at the right side of the healthy lung, may be explained by an higher volume of the right pulmonary lobe. Whereas in benign displacing processes the relation activity to volume was similar to the one of the healthy lung, a strongly reduced perfusion together with inconspicuous lung volumes became apparent with malignant tumors. In addition to the great morphological evidence of CT and SPECT studies, additional informations regarding the dignity of displacing processes may be derived from the quantitative evaluation of both methods. (orig.) [de

  14. The value of CT in detecting pathologic bowel perforation

    International Nuclear Information System (INIS)

    Chang, Jong Wun; Shin, Joo Yong; Kim, Hong; Rhee, Chang Soo; Lee, Sung Moon; Joo, Yang Goo; Suh, Soo Jhi

    1997-01-01

    To evaluate the usefulness of CT for assessing the location and cause of pathologic gastrointestinal perforation. A retrospective analysis of abdominal CT was performed in 27 perforations of 26 patients with underlying gastrointestinal pathology. Fifteen benign and 12 malignant perforations consisted of five gastric cancers, one gastric ulcer, ten duodenal bulb ulcers. two bowel adhesions, one jejunal metastasis from lung cancer, one ileocolic Crohn's disease, one radiation colitis and six colon cancers. CT scans were evaluated for 1) diagnosis of bowel perforation, 2) assessment of the cause and site of perforation, and, in particular, differentiation between benignancy and malignancy, and 3) complications and their extent. CT easily detected varying amounts of free air or fluid collection, and infiltration or abscess formation adjacent to the main lesion, and the diagnosis of gastrointestinal perforation was therefore easy. In 11 of the 12 malignancies (92%), primary tumor was diagnosed, but detection of the site of perforation was possible in only seven cases(7/12, 58%). The 15 benign lesions revealed nonspecific CT findings, and the perforation site could be presumed in six (6/15, 40%). In one case of Crohn's disease, the primary cause was visualized. Among six colonic cancers, four pericolic abscesses and two fistulas to adjacent organs were found, but there was no evidence of diffuse peritonitis. CT was helpful to lead to optimal treatment of pathologic gastrointestinal On CT the detectability of perforation, primary benign or malignant lesion, perforation site and extent of complication was high, and this modality was therefore a useful indicator of the optimal treatment for pathologic gastrointestinal perforations.=20

  15. Usefulness of FDG PET/CT in determining benign from malignant endobronchial obstruction

    International Nuclear Information System (INIS)

    Cho, Arthur; Kang, Won Jun; Cho, Ho Jin; Lee, Jae-hoon; Yun, Mijin; Lee, Jong Doo; Hur, Jin

    2011-01-01

    To evaluate the usefulness of FDG PET/CT to differentiate malignant endobronchial lesions with distal atelectasis from benign bronchial stenosis. This retrospective study reviewed 84 patients who underwent contrast-enhanced chest CT and then PET/CT and had histological (n = 81) or follow-up imaging (n = 3) confirmation. Two chest radiologists reviewed initial chest CT and determined endobronchial lesions to be malignant or benign. Two nuclear medicine physicians reviewed PET/CT for FDG uptake at the obstruction site and measured SUV. Malignancy was considered when increased FDG uptake was seen in the obstruction site, regardless of FDG within the atelectatic lung. The sensitivity, specificity and accuracy of chest CT was 95%, 48% and 84%, compared with 95%, 91% and 94% for PET/CT. Benign obstructive lesions showed statistically lower FDG uptake than malignant obstructions (benign SUV 2.5 ± 0.84; malignant SUV 11.8 ± 5.95, p < 0.001). ROC analysis showed an SUV cut-off value of 3.4 with highest sensitivity of 94% and specificity of 91%. Increased FDG PET/CT uptake at the obstruction site indicates a high probability of malignancy, while benign lesions show low FDG uptake. Careful evaluation of FDG uptake pattern at the obstruction site is helpful in the differentiation between benign and malignant endobronchial lesions. (orig.)

  16. Usefulness of FDG PET/CT in determining benign from malignant endobronchial obstruction

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Arthur; Kang, Won Jun; Cho, Ho Jin; Lee, Jae-hoon; Yun, Mijin; Lee, Jong Doo [Yonsei University Health System, Division of Nuclear Medicine, Department of Radiology, Seoul (Korea, Republic of); Hur, Jin [Yonsei University Health System, Department of Radiology, Seoul (Korea, Republic of)

    2011-05-15

    To evaluate the usefulness of FDG PET/CT to differentiate malignant endobronchial lesions with distal atelectasis from benign bronchial stenosis. This retrospective study reviewed 84 patients who underwent contrast-enhanced chest CT and then PET/CT and had histological (n = 81) or follow-up imaging (n = 3) confirmation. Two chest radiologists reviewed initial chest CT and determined endobronchial lesions to be malignant or benign. Two nuclear medicine physicians reviewed PET/CT for FDG uptake at the obstruction site and measured SUV. Malignancy was considered when increased FDG uptake was seen in the obstruction site, regardless of FDG within the atelectatic lung. The sensitivity, specificity and accuracy of chest CT was 95%, 48% and 84%, compared with 95%, 91% and 94% for PET/CT. Benign obstructive lesions showed statistically lower FDG uptake than malignant obstructions (benign SUV 2.5 {+-} 0.84; malignant SUV 11.8 {+-} 5.95, p < 0.001). ROC analysis showed an SUV cut-off value of 3.4 with highest sensitivity of 94% and specificity of 91%. Increased FDG PET/CT uptake at the obstruction site indicates a high probability of malignancy, while benign lesions show low FDG uptake. Careful evaluation of FDG uptake pattern at the obstruction site is helpful in the differentiation between benign and malignant endobronchial lesions. (orig.)

  17. Displacement ventilation

    DEFF Research Database (Denmark)

    Kosonen, Risto; Melikov, Arsen Krikor; Mundt, Elisabeth

    The aim of this Guidebook is to give the state-of-the art knowledge of the displacement ventilation technology, and to simplify and improve the practical design procedure. The Guidebook discusses methods of total volume ventilation by mixing ventilation and displacement ventilation and it gives...... insights of the performance of the displacement ventilation. It also shows practical case studies in some typical applications and the latest research findings to create good local micro-climatic conditions....

  18. Field displacement during external radiotherapy in prostatic adenocarcinoma treated with radioactive 198Au implants and external irradiation

    International Nuclear Information System (INIS)

    Lennernaes, B.; Letocha, H.; Rikner, G.; Magnusson, A.; Nilsson, S.

    1995-01-01

    The purpose of this work was to study displacement error and internal movements of the prostate during external beam radiotherapy. Verification films in the frontal (n=194) and lateral (n=64) portals were investigated in 14 patients treated with radioactive 198 Au implants. Displacement errors of two implants were investigated. In seven patients, filling of the rectum and the bladder with contrast medium or isotonic saline was performed during CT investigation for planning purposes to detect movements of the prostate. Most (95%) of the displacement errors were less than 10 mm in the frontal portal and less than 15 mm in the lateral portals. No correlation to the patient's weight was found. The displacement errors were randomly distributed. The spatial relations between the implants were not altered during the treatments. Small movements of the prostate were observed. To conclude, the positioning system employed at present (laser) can be sufficient for the margins used (2 cm). In lateral portals, however, the system did not have the ability to detect a possible systematic displacement error from simulator to accelerator. The intention is to decrease the margins to 1 cm, which will necessitate a better positioning system. (orig.)

  19. CT of abdominal abscesses

    International Nuclear Information System (INIS)

    Korobkin, M.T.

    1987-01-01

    The imaging search for a suspected abdominal abscess is common in hospitalized patients, especially after recent abdominal surgery. This paper examines the role of CT in the detection, localization, and treatment of abdominal abscess. The accuracy, limitations, and technical aspects of CT in this clinical setting are discussed. The diagnosis of an abscess is based on the demonstration of a circumscribed abnormal fluid collection. Although percutaneous aspiration with gram stain and culture is usually indicated to differentiate abscess from other fluid collections, the CT-based detection of extraluminal gas bubbles makes the diagnosis of an abscess highly likely. CT is compared with conventional radiographic studies, US, and radio-nuclide imaging. Specific CT and clinical features of abscesses in the following sites are emphasized: subphrenic space, liver, pancreas, kidneys, psoas muscle, appendix, and colonic diverticula. Most abdominal abscesses can be successfully treated with percutaneous drainage techniques. The techniques, results, and limitations of percutaneous abscess drainage are reviewed

  20. Multiphase CT scanning and different intravenous contrast media concentrations in combined F-18-FDG PET/CT: Effect on quantitative and clinical assessment

    Energy Technology Data Exchange (ETDEWEB)

    Rebiere, Marilou, E-mail: Marilou.Rebiere@rwth-aachen.de [Department of Nuclear Medicine, University Hospital RWTH Aachen, Pauwelsstrasse 30, 52057 Aachen (Germany); Verburg, Frederik A., E-mail: fverburg@ukaachen.de [Department of Nuclear Medicine, University Hospital RWTH Aachen, Pauwelsstrasse 30, 52057 Aachen (Germany); Department of Nuclear Medicine, Maastricht University Medical Center, P. Debeylaan 25, 6202 AZ Maastricht (Netherlands); Palmowski, Moritz, E-mail: mpalmowski@ukaachen.de [Department of Nuclear Medicine, University Hospital RWTH Aachen, Pauwelsstrasse 30, 52057 Aachen (Germany); Department of Radiology, University Hospital RWTH Aachen, Pauwelsstrasse 30, 52057 Aachen (Germany); Department of Experimental Molecular Imaging, University Hospital RWTH Aachen, Pauwelsstrasse 30, 52057 Aachen (Germany); Krohn, Thomas, E-mail: tkrohn@ukaachen.de [Department of Nuclear Medicine, University Hospital RWTH Aachen, Pauwelsstrasse 30, 52057 Aachen (Germany); Pietsch, Hubertus, E-mail: hubertus.pietsch@bayer.com [Contrast Media Research, Bayer Pharma AG, Muellerstr. 178, 13353 Berlin (Germany); Kuhl, Christiane K., E-mail: ckuhl@ukaachen.de [Department of Radiology, University Hospital RWTH Aachen, Pauwelsstrasse 30, 52057 Aachen (Germany); Mottaghy, Felix M., E-mail: fmottaghy@ukaachen.de [Department of Nuclear Medicine, University Hospital RWTH Aachen, Pauwelsstrasse 30, 52057 Aachen (Germany); Department of Nuclear Medicine, Maastricht University Medical Center, P. Debeylaan 25, 6202 AZ Maastricht (Netherlands); Behrendt, Florian F., E-mail: fbehrendt@ukaachen.de [Department of Nuclear Medicine, University Hospital RWTH Aachen, Pauwelsstrasse 30, 52057 Aachen (Germany)

    2012-08-15

    Purpose: To evaluate the influence of multiphase CT scanning and different intravenous contrast media on contrast enhancement, attenuation correction and image quality in combined PET/CT. Material and methods: 140 patients were prospectively enrolled for F-18-FDG-PET/CT including a low-dose unenhanced, arterial and venous contrast enhanced CT. The first (second) 70 patients, received contrast medium with 370 (300) mg iodine/ml. The iodine delivery rate (1.3 mg/s) and total iodine load (44.4 g) were identical for both groups. Contrast enhancement and maximum and mean standardized FDG uptake values (SUVmax and SUVmean) were determined for the un-enhanced, arterial and venous PET/CT at multiple anatomic sites and PET reconstructions were visually evaluated. Results: Arterial contrast enhancement was significantly higher for the 300 mg/ml contrast medium compared to 370 mg I/ml at all anatomic sites. Venous enhancement was not different between the two contrast media. SUVmean and SUVmax were significantly higher for the contrast enhanced compared to the non-enhanced PET/CT at all anatomic sites (all P < 0.001). Tracer uptake was significantly higher in the arterial than in the venous PET/CT in the arteries using both contrast media (all P < 0.001). No differences in tracer uptake were found between the contrast media (all P > 0.05). Visual assessment revealed no relevant differences between the different PET reconstructions. Conclusions: There is no relevant qualitative influence on the PET scan from the use of different intravenous contrast media in its various phases in combined multiphase PET/CT. For quantitative analysis of tracer uptake it is required to use an identical PET/CT protocol.

  1. From Site Data to Safety Assessment: Analysis of Present and Future Hydrological Conditions at a Coastal Site in Sweden

    International Nuclear Information System (INIS)

    Berglund, Sten; Bosson, Emma; Sassner, Mona

    2013-01-01

    This paper presents an analysis of present and future hydrological conditions at the Forsmark site in Sweden, which has been proposed as the site for a geological repository for spent nuclear fuel. Forsmark is a coastal site that changes in response to shoreline displacement. In the considered time frame (until year 10 000 ad), the hydrological system will be affected by landscape succession associated with shoreline displacement and changes in vegetation, regolith stratigraphy, and climate. Based on extensive site investigations and modeling of present hydrological conditions, the effects of different processes on future site hydrology are quantified. As expected, shoreline displacement has a strong effect on local hydrology (e.g., groundwater flow) in areas that change from sea to land. The comparison between present and future land areas emphasizes the importance of climate variables relative to other factors for main hydrological features such as water balances

  2. Lack of Correlation Between External Fiducial Positions and Internal Tumor Positions During Breath-Hold CT

    International Nuclear Information System (INIS)

    Hunjan, Sandeep; Starkschall, George; Prado, Karl; Dong Lei; Balter, Peter

    2010-01-01

    Purpose: For thoracic tumors, if four-dimensional computed tomography (4DCT) is unavailable, the internal margin can be estimated by use of breath-hold (BH) CT scans acquired at end inspiration (EI) and end expiration (EE). By use of external surrogates for tumor position, BH accuracy is estimated by minimizing the difference between respiratory extrema BH and mean equivalent-phase free breathing (FB) positions. We tested the assumption that an external surrogate for BH accuracy correlates with internal tumor positional accuracy during BH CT. Methods and Materials: In 16 lung cancer patients, 4DCT images, as well as BH CT images at EI and EE, were acquired. Absolute differences between BH and mean equivalent-phase (FB) positions were calculated for both external fiducials and gross tumor volume (GTV) centroids as metrics of external and internal BH accuracy, respectively, and the results were correlated. Results: At EI, the absolute difference between mean FB and BH fiducial displacement correlated poorly with the absolute difference between FB and BH GTV centroid positions on CT images (R 2 = 0.11). Similarly, at EE, the absolute difference between mean FB and BH fiducial displacements correlated poorly with the absolute difference between FB and BH GTV centroid positions on CT images (R 2 = 0.18). Conclusions: External surrogates for tumor position are not an accurate metric of BH accuracy for lung cancer patients. This implies that care should be taken when using such an approach because an incorrect internal margin could be generated.

  3. Job Displacement and Crime

    DEFF Research Database (Denmark)

    Bennett, Patrick; Ouazad, Amine

    We use a detailed employer-employee data set matched with detailed crime information (timing of crime, fines, convictions, crime type) to estimate the impact of job loss on an individual's probability to commit crime. We focus on job losses due to displacement, i.e. job losses in firms losing...... a substantial share of their workers, for workers with at least three years of tenure. Displaced workers are more likely to commit offenses leading to conviction (probation, prison terms) for property crimes and for alcohol-related traffic violations in the two years following displacement. We find no evidence...... that displaced workers' propensity to commit crime is higher than non-displaced workers before the displacement event; but it is significantly higher afterwards. Displacement impacts crime over and above what is explained by earnings losses and weeks of unemployment following displacement....

  4. The value of CT in detecting pathologic bowel perforation

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Jong Wun; Shin, Joo Yong; Kim, Hong; Rhee, Chang Soo; Lee, Sung Moon; Joo, Yang Goo; Suh, Soo Jhi [Keimyung Univ. School of Medicine, Taegu (Korea, Republic of)

    1997-10-01

    To evaluate the usefulness of CT for assessing the location and cause of pathologic gastrointestinal perforation. A retrospective analysis of abdominal CT was performed in 27 perforations of 26 patients with underlying gastrointestinal pathology. Fifteen benign and 12 malignant perforations consisted of five gastric cancers, one gastric ulcer, ten duodenal bulb ulcers. two bowel adhesions, one jejunal metastasis from lung cancer, one ileocolic Crohn's disease, one radiation colitis and six colon cancers. CT scans were evaluated for (1) diagnosis of bowel perforation, (2) assessment of the cause and site of perforation, and, in particular, differentiation between benignancy and malignancy, and (3) complications and their extent. CT easily detected varying amounts of free air or fluid collection, and infiltration or abscess formation adjacent to the main lesion, and the diagnosis of gastrointestinal perforation was therefore easy. In 11 of the 12 malignancies (92%), primary tumor was diagnosed, but detection of the site of perforation was possible in only seven cases(7/12, 58%). The 15 benign lesions revealed nonspecific CT findings, and the perforation site could be presumed in six (6/15, 40%). In one case of Crohn's disease, the primary cause was visualized. Among six colonic cancers, four pericolic abscesses and two fistulas to adjacent organs were found, but there was no evidence of diffuse peritonitis. CT was helpful to lead to optimal treatment of pathologic gastrointestinal On CT the detectability of perforation, primary benign or malignant lesion, perforation site and extent of complication was high, and this modality was therefore a useful indicator of the optimal treatment for pathologic gastrointestinal perforations.=20.

  5. Clinical application of early PET-CT imaging after radiofrequency ablation of liver neoplasms

    International Nuclear Information System (INIS)

    Liu Zhaoyu; Chang Zhihui; Lu Zaiming; Xin Jun; Wang Xiaoming; Guo Qiyong

    2009-01-01

    Objective: To evaluate the application of early 18 F-FDG PET-CT imaging after radiofrequency ablation (RFA) of hepatic malignancies. Methods: Fifteen patients with liver tumors (five hepatocellular carcinoma, ten colorectal cancer liver metastasis) underwent RFA as part of clinical management. The lesions were all hypermetabolic on PET-CT performed within 2 weeks prior to RFA. All subjects underwent 18 F-FDG PET-CT (early PET-CT) within 24 hours after RFA. Total photopenia, focal uptake, and rim-shaped uptake were regarded as complete ablation, residual tumor, and inflammation, respectively. Follow-up PET-CT scans were performed as the reference standard. Results: Twelve patients showed total photopenia at the ablation site on the early PET-CT scan, and in all of these patients, total photopenia at the ablation sites was seen on the follow-up PET-CT scans. Two patients had focal uptake at the ablation sites on the early PET-CT scan, and both of these foci increased in size and intensity, which were compatible with residual tumors at the time of ablation. Only one patient had rim-shaped uptake on the early PET-CT scan. The rim-shaped uptake disappeared on PET-CT performed 3 months later, which indicated the nature of inflammation. Conclusions: There is infrequent inflammatory uptake at the RFA site of liver tumors on 18 F-FDG PET-CT if scanning is performed within 24 hours after ablation. Thus, early PET- CT has the potential to evaluate the efficacy of an RFA procedure by indicating tumor-free as total photopenia and residual tumors as focal uptake. (authors)

  6. CT and MR imaging findings of sphenoidal masses

    Energy Technology Data Exchange (ETDEWEB)

    Takahashi, Shoki; Higano, Shuichi (Tohoku Univ., Sendai (Japan). School of Medicine); Ishii, Kiyoshi (and others)

    1994-07-01

    CT and MR imaging findings of 57 sphenoidal masses were retrospectively reviewed to assess the possibility of differential diagnosis between them. Various kinds of masses such as pituitary adenoma, epipharyngeal cancer, mucocele, chordoma, chondroma, chondrosarcoma, distant metastasis, multiple myeloma, fibrous dysplasia, craniopharyngioma, hemangiopericytoma, giant cell tumor, primary sphenoidal cancer, malignant melanoma, leukemia, histiocytosis X, and giant cell tumor were included in this series. CT scanning was performed in all cases using a spin-echo pulse sequence. The relative density of the masses, bony changes and calcification were evaluated on CT, and on MR images, signal intensity of the masses relative to the normal gray matter, contrast enhancement and extension/contour were evaluated. Although no single feature appeared to be specific to the masses, detection of calcification on CT, identification of the normal pituitary gland as deformed or displaced on T1-weighted images, signal intensity on T2-weighted images, and extension of the masses seemed to be useful and should be examined in terms of their ability to assist in differential diagnosis. Finally, accommodative classification of sphenoidal masses primarily based on presumed origin or mode of extension was attempted. (author).

  7. The added value of {sup 68}Ga-DOTA-TATE-PET to contrast-enhanced CT for primary site detection in CUP of neuroendocrine origin

    Energy Technology Data Exchange (ETDEWEB)

    Kazmierczak, Philipp M. [Klinikum der Universitaet Muenchen, Institut fuer Klinische Radiologie, Muenchen (Germany); Ludwig-Maximilians-University Hospital Munich, Institute for Clinical Radiology, Muenchen (Germany); Rominger, Axel; Wenter, Vera [Ludwig-Maximilians-University Hospital Munich, Department of Nuclear Medicine, Muenchen (Germany); Spitzweg, Christine; Auernhammer, Christoph [Ludwig-Maximilians-University Hospital Munich, Department of Internal Medicine II, Muenchen (Germany); Angele, Martin K. [Ludwig-Maximilians-University Hospital Munich, Department of General, Visceral, Transplantation, Vascular and Thoracic Surgery, Muenchen (Germany); Rist, Carsten; Cyran, Clemens C. [Ludwig-Maximilians-University Hospital Munich, Institute for Clinical Radiology, Muenchen (Germany)

    2017-04-15

    To quantify the additional value of {sup 68}Ga-DOTA-TATE PET/CT in comparison with contrast-enhanced CT alone for primary tumour detection in neuroendocrine cancer of unknown primary (CUP-NET). In total, 38 consecutive patients (27 men, 11 women; mean age 62 years) with histologically proven CUP-NET who underwent a contrast-enhanced {sup 68}Ga-DOTA-TATE PET/CT scan for primary tumour detection and staging between 2010 and 2014 were included in this IRB-approved retrospective study. Two blinded readers independently analysed the contrast-enhanced CT and {sup 68}Ga-DOTA-TATE PET datasets separately and noted from which modality they suspected a primary tumour. Consensus was reached if the results were divergent. Postoperative histopathology (24 patients) and follow-up {sup 68}Ga-DOTA-TATE PET/CT imaging (14 patients) served as the reference standards and statistical measures of diagnostic accuracy were calculated accordingly. The majority of confirmed primary tumours were located in the abdomen (ileum in 19 patients, pancreas in 12, lung in 2, small pelvis in 1). High interobserver agreement was noted regarding the suspected primary tumour site (Cohen's k 0.90, p < 0.001). {sup 68}Ga-DOTA-TATE PET demonstrated a significantly higher sensitivity (94 % vs. 63 %, p = 0.005) and a significantly higher accuracy (87 % vs. 68 %, p = 0.003) than contrast-enhanced CT. Ga-DOTA-TATE PET/CT compared with contrast-enhanced CT alone provides an improvement in sensitivity of 50 % and an improvement in accuracy of 30 % in primary tumour detection in CUP-NET. (orig.)

  8. MRI anatomy of anteriorly displaced anus: what obstructs defecation?

    International Nuclear Information System (INIS)

    AbouZeid, Amr Abdelhamid; Mohammad, Shaimaa Abdelsattar; Khairy, Khaled Talaat

    2014-01-01

    Anteriorly displaced anus is an anomaly that is debated with regard to its nomenclature, diagnosis and management. To describe MRI anatomy of the anal canal in children with anteriorly displaced anus and its impact on the process of defecation. We prospectively examined ten children (7 girls, 3 boys; age range 7 months to 8 years, mean 3 years) with anteriorly displaced anus between August 2009 and April 2012. Noncontrast MRI examinations were performed on a 1.5-T magnet. T1- and T2-weighted turbo spin-echo images were acquired in axial, sagittal and coronal planes of the pelvis. The anorectal angle and the relative hiatal distance were measured in mid-sagittal images, and compared with those of a control group using the Mann-Whitney test. In children with anteriorly displaced anus, no anatomical abnormality was depicted at the level of the proximal anal canal. However, the distal anal canal was displaced anteriorly, running out its external muscle cuff, which remained un-displaced at the usual site of the anus. This changes the orientation of the central axis of the anal canal by passing across instead of along the fibers of the longitudinal muscle coat. Children with anteriorly displaced anus had a more obtuse anorectal angle (mean 112.1 ), which was significantly greater than that of the control group (mean 86.2 ). MRI is a valuable tool in studying the anatomy of the anal canal in children with anteriorly displaced anus. The abnormal orientation of the longitudinal muscle across the anal canal can explain the obstructed defecation in these children. Based on this study, it might be of interest to use MRI in studying equivocal cases and children with unexplained constipation. (orig.)

  9. MRI anatomy of anteriorly displaced anus: what obstructs defecation?

    Energy Technology Data Exchange (ETDEWEB)

    AbouZeid, Amr Abdelhamid [Ain-Shams University, Department of Pediatric Surgery, Cairo (Egypt); Mohammad, Shaimaa Abdelsattar; Khairy, Khaled Talaat [Ain-Shams University, Department of Radiodiagnosis, Cairo (Egypt)

    2014-07-15

    Anteriorly displaced anus is an anomaly that is debated with regard to its nomenclature, diagnosis and management. To describe MRI anatomy of the anal canal in children with anteriorly displaced anus and its impact on the process of defecation. We prospectively examined ten children (7 girls, 3 boys; age range 7 months to 8 years, mean 3 years) with anteriorly displaced anus between August 2009 and April 2012. Noncontrast MRI examinations were performed on a 1.5-T magnet. T1- and T2-weighted turbo spin-echo images were acquired in axial, sagittal and coronal planes of the pelvis. The anorectal angle and the relative hiatal distance were measured in mid-sagittal images, and compared with those of a control group using the Mann-Whitney test. In children with anteriorly displaced anus, no anatomical abnormality was depicted at the level of the proximal anal canal. However, the distal anal canal was displaced anteriorly, running out its external muscle cuff, which remained un-displaced at the usual site of the anus. This changes the orientation of the central axis of the anal canal by passing across instead of along the fibers of the longitudinal muscle coat. Children with anteriorly displaced anus had a more obtuse anorectal angle (mean 112.1 ), which was significantly greater than that of the control group (mean 86.2 ). MRI is a valuable tool in studying the anatomy of the anal canal in children with anteriorly displaced anus. The abnormal orientation of the longitudinal muscle across the anal canal can explain the obstructed defecation in these children. Based on this study, it might be of interest to use MRI in studying equivocal cases and children with unexplained constipation. (orig.)

  10. Four-dimensional measurement of intrafractional respiratory motion of pancreatic tumors using a 256 multi-slice CT scanner

    International Nuclear Information System (INIS)

    Mori, Shinichiro; Hara, Ryusuke; Yanagi, Takeshi; Sharp, Gregory C.; Kumagai, Motoki; Asakura, Hiroshi; Kishimoto, Riwa; Yamada, Shigeru; Kandatsu, Susumu; Kamada, Tadashi

    2009-01-01

    Purpose: To quantify pancreas and pancreatic tumor movement due to respiratory motion using volumetric cine CT images. Materials and methods: Six patients with pancreatic tumors were scanned in cine mode with a 256 multi-slice CT scanner under free breathing conditions. Gross tumor volume (GTV) and pancreas were manually contoured on the CT data set by a radiation oncologist. Intrafractional respiratory movement of the GTV and pancreas was calculated, and the results were compared between the respiratory ungated and gated phases, which is a 30% duty cycle around exhalation. Results: Respiratory-induced organ motion was observed mainly in the anterior abdominal side than the posterior side. Average GTV displacement (ungated/gated phases) was 0.7 mm/0.2 mm in both the left and right directions, and 2.5 mm/0.9 mm in the anterior, 0.1 mm/0 mm in the posterior, and 8.9 mm/2.6 mm in the inferior directions. Average pancreas center of mass displacement relative to that at peak exhalation was mainly in the inferior direction, at 9.6 mm in the ungated phase and 2.3 mm in the gated phase. Conclusions: By allowing accurate determination of the margin, quantitative analysis of tumor and pancreas displacement provides useful information in treatment planning in all radiation approaches for pancreatic tumors.

  11. Introduction of X-ray CT application in geotechnical engineering - theory and practice

    International Nuclear Information System (INIS)

    Otani, J; Watanabe, Y; Chevalier, B

    2010-01-01

    In this paper, fundamental issues on the use of X-ray CT to geomaterials were discussed, which were the contents of what you have to know about the use of X-ray CT, especially for geomaterials or granular materials. Then, two of our recent studies were introduced, which are 1) the use of X-ray CT data to quantitative measurements such as deformation and strains and 2) comparison of X-ray CT results with numerical analysis. Here, the triaxial compression test on sand was conducted and the image analysis technique called 'Digital Image Correlation' was used to measure displacement and strain fields in the soils using a large number of CT images. For the second topic, one of the advantages on the use of X-ray CT is to investigate the behavior in three dimensions. Here, so called trap door test was conducted with the materials of glass beads and the shape of the square door. DEM analysis was also conducted for the simulation of this behaviour and both results were compared. Based on all the results in this paper, the effectiveness of the use of X-ray CT in geomechanics and geotechnical engineering was revealed.

  12. [Positioning errors of CT common rail technique in intensity-modulated radiotherapy for nasopharyngeal carcinoma].

    Science.gov (United States)

    Tian, Fei; Xu, Zihai; Mo, Li; Zhu, Chaohua; Chen, Chaomin

    2012-11-01

    To evaluate the value of CT common rail technique for application in intensity-modulated radiotherapy for nasopharyngeal carcinoma (NPC). Twenty-seven NPC patients underwent Somatom CT scans using the Siemens CTVision system prior to the commencement of the radiotherapy sessions. The acquired CT images were registered with the planning CT images using the matching function of the system to obtain the linear set-up errors of 3 directions, namely X (left to right), Y (superior to inferior), and Z (anterior to posterior). The errors were then corrected online on the moving couch. The 27 NPC patients underwent a total of 110 CT scans and the displacement deviations of the X, Y and Z directions were -0.16∓1.68 mm, 0.25∓1.66 mm, and 0.33∓1.09 mm, respectively. CT common rail technique can accurately and rapidly measure the space error between the posture and the target area to improve the set-up precision of intensity-modulated radiotherapy for NPC.

  13. Displacement Ventilation

    DEFF Research Database (Denmark)

    Nielsen, Peter Vilhelm

    Displacement ventilation is an interesting new type of air distribution principle which should be considered in connection with design of comfort ventilation in both smal1 and large spaces. Research activities on displacement ventilation are large all over the world and new knowledge of design...... methods appears continuously. This book gives an easy introduction to the basis of displacement ventilation and the chapters are written in the order which is used in a design procedure. The main text is extended by five appendices which show some of the new research activities taking place at Aalborg...

  14. Radiological study of the secondary reduction effect of early functional exercise on displaced intra-articular calcaneal fractures after internal compression fixation.

    Science.gov (United States)

    Chen, Wei; Liu, Bo; Lv, Hongzhi; Su, Yanling; Chen, Xiao; Zhu, Yanbin; Du, Chenguang; Zhang, Xiaolin; Zhang, Yingze

    2017-09-01

    Early post-operative exercise and weight-bearing activities are found to improve the functional recovery of patients with displaced intra-articular calcaneal fractures (DIACFs). We hypothesized that early functional exercise after surgery might have a secondary reduction effect on the subtalar joint, in particular the smaller fracture fragments that were not fixed firmly. A prospective study was conducted to verify this hypothesis. From December 2012 to September 2013, patients with unilateral DIACFs were enrolled and received a treatment consisting of percutaneous leverage and minimally invasive fixation. After surgery, patients in the study group started exercising on days two to three, using partial weight bearing starting week three, and full weight bearing starting week 12. Patients in the control group followed a conventional post-operative protocol of partial weight bearing after week six and full weight bearing after the bone healed. Computed tomography (CT) scanning was performed at post-operative day one, week four, week eight, and week 12 to reconstruct coronal, sagittal, and axial images, on which the maximal residual displacements of the fractures were measured. Function was evaluated using the American Orthopaedic Foot and Ankle Society (AOFAS) scoring scale at the 12th post-operative month. Twenty-eight patients in the study group and 32 in the control group were followed up for more than 12 months; their data were collected and used for the final analysis. Repeated-measures analysis of variance (ANOVA) of the maximal residual displacements of the fracture measured on CT images revealed significant differences between the study and the control groups. There were interaction effects between group and time point. Except for the first time point, the differences between the groups at all studied time points were significant. In the study group, the differences between all studied time points were significant. Strong correlations were observed between

  15. The use of a single titanium microplate in displaced pediatric parasymphysial mandibular fractures.

    Science.gov (United States)

    Abdullah, Walid A

    2009-07-01

    The objective of this study was to evaluate the use of one titanium microplate in the fixation of displaced pediatric parasymphysial mandibular fractures. The study was conducted on 7 children in the mixed dentition stage with displaced parasymphysial fracture. Patients' age ranged between 5 years 9 months and 8 years 4 months with an average of 7 years 1 month. Fractured bone segments were exposed, reduced and then fixed using 1.5 linear microplates at the inferior border of the mandible using monocortical screws, with 1.5 mm in diameter and 5 mm in length. Stainless steel wire was used as a tension band by ligating the teeth around the fracture line. Patients were followed up for occlusion and stability clinically and radiographically (panoramic X-ray and CT). According to clinical and radiographic post-operative follow-up, none of the patients showed displacement of the fixed bony segments. The present study concluded that using one microplate with 1.5 monocortical microscrews and dental tension band by a stainless steel wire could be adequate for fixing displaced pediatric parasymphysial mandibular fractures. This technique has the following advantages: decreases the amount of titanium used, decreases the risk of injury of the roots and teeth buds, and decreases the cost and time of surgery.

  16. CT-diagnosis of temporal bone trauma

    Energy Technology Data Exchange (ETDEWEB)

    Valavanis, A.; Stuckmann, G.; Antonucci, F.; Schubiger, O.

    1986-02-01

    73 patients with 78 fractures of the temporal bone were examined by high-resolution computed tomography (CT). Analysis of the CT-findings disclosed 55 longitudinal, 12 transverse, 8 combined and 3 atypical fractures. For determination of the fracture type, axial sections usually proved sufficient. However, for precise topographic analysis of the course of the fracture additional coronal sections were necessary in most of the cases. In the radiologic evaluation of temporal bone fractures detection of associated. Complications is clinically important since these can be surgically corrected. In this series 20 lesions of the ossicular chain were demonstrated by the combined performance of axial and coronal sections and sagittal reformations. High resolution CT demonstrated a lesion of the facial nerve canal in 79% of a patient group with traumatic facial nerve palsy. The most frequent site of injury of the facial nerve canal was the region of the geniculate ganglion. With the use of metrizaminde-CT-cisternography the site of cerebrospinal fluid leakage was demonstrated in 7 of 9 patients with liquorrhea. It is concluded that high-resolution CT is the radiologic method of choice for both topographic evaluation of temporal bone fractures and detection and precise localization of fracture-complications. (orig.).

  17. CT-SPECT fusion to correlate radiolabeled monoclonal antibody uptake with abdominal CT findings

    International Nuclear Information System (INIS)

    Kramer, E.L.; Noz, M.E.; Sanger, J.J.; Megibow, A.J.; Maguire, G.Q.

    1989-01-01

    To enhance the information provided by computed tomography (CT) and single photon emission computed tomography (SPECT) performed with radiolabeled, anti-carcinoembryonic antigen monoclonal antibody (MoAb), the authors performed fusion of these types of images from eight subjects with suspected colorectal adenocarcinoma. Section thickness and pixel size of the two studies were matched, coordinates of corresponding points from each study were identified, and CT sections were translated, rotated, and reprojected to match the corresponding SPECT scans. The CT-SPECT fusion enabled identification of anatomic sites of tumor-specific MoAb accumulation in four cases, showed non-specific MoAb accumulation in two, and helped confirm information only suggested by the two studies separately in one

  18. Contactless sub-millimeter displacement measurements

    Science.gov (United States)

    Sliepen, Guus; Jägers, Aswin P. L.; Bettonvil, Felix C. M.; Hammerschlag, Robert H.

    2008-07-01

    Weather effects on foldable domes, as used at the DOT and GREGOR, are investigated, in particular the correlation between the wind field and the stresses caused to both metal framework and tent clothing. Camera systems measure contactless the displacement of several dome points. The stresses follow from the measured deformation pattern. The cameras placed near the dome floor do not disturb telescope operations. In the set-ups of DOT and GREGOR, these cameras are up to 8 meters away from the measured points and must be able to detect displacements of less than 0.1 mm. The cameras have a FireWire (IEEE1394) interface to eliminate the need for frame grabbers. Each camera captures 15 images of 640 × 480 pixels per second. All data is processed on-site in real-time. In order to get the best estimate for the displacement within the constraints of available processing power, all image processing is done in Fourier-space, with all convolution operations being pre-computed once. A sub-pixel estimate of the peak of the correlation function is made. This enables to process the images of four cameras using only one commodity PC with a dual-core processor, and achieve an effective sensitivity of up to 0.01 mm. The deformation measurements are well correlated to the simultaneous wind measurements. The results are of high interest to upscaling the dome design (ELTs and solar telescopes).

  19. Compression of the posterior fossa venous sinuses by epidural hemorrhage simulating venous sinus thrombosis: CT and MR findings

    Energy Technology Data Exchange (ETDEWEB)

    Singh, Sumit; Ramakrishnaiah, Raghu H.; Hegde, Shilpa V.; Glasier, Charles M. [University of Arkansas for Medical Sciences, Pediatric Radiology, Little Rock, AR (United States)

    2016-01-15

    Posterior fossa dural venous sinus thrombus is a well-described complication of head trauma, especially when fracture crosses the dural sinus grooves or in association with epidural hemorrhage. We have found that post-traumatic posterior fossa epidural hematoma compressing a dural venous sinus can mimic dural venous thrombus. To discuss the CT and MRI findings of posterior fossa epidural hemorrhages simulating sinus thrombosis, to make radiologists aware of this important imaging pitfall. We describe radiologic findings in four children in whom a posterior fossa epidural hemorrhage mimicked dural venous sinus thrombus. Routine CT head and CT venography were obtained on Toshiba volume and helical CT scanners. MRI and MR venography were performed on a Philips scanner. In all cases there was medial displacement and compression of the posterior fossa dural venous sinuses without intraluminal thrombosis. The epidural hemorrhage was seen tracking along sinus grooves in the occipital bone, peeling the dura containing the sinuses from the calvarium and compressing the sinus, simulating thrombosis on axial CT views. Both venous sinus thrombosis and posterior fossa epidural hemorrhages in children are well-described complications of head trauma. Posterior fossa epidural hemorrhage can mimic a sinus thrombus by compressing and displacing the sinuses. It is important to recognize this pitfall because treatment of a suspected thrombus with anticoagulation can worsen epidural hemorrhage. (orig.)

  20. Compression of the posterior fossa venous sinuses by epidural hemorrhage simulating venous sinus thrombosis: CT and MR findings

    International Nuclear Information System (INIS)

    Singh, Sumit; Ramakrishnaiah, Raghu H.; Hegde, Shilpa V.; Glasier, Charles M.

    2016-01-01

    Posterior fossa dural venous sinus thrombus is a well-described complication of head trauma, especially when fracture crosses the dural sinus grooves or in association with epidural hemorrhage. We have found that post-traumatic posterior fossa epidural hematoma compressing a dural venous sinus can mimic dural venous thrombus. To discuss the CT and MRI findings of posterior fossa epidural hemorrhages simulating sinus thrombosis, to make radiologists aware of this important imaging pitfall. We describe radiologic findings in four children in whom a posterior fossa epidural hemorrhage mimicked dural venous sinus thrombus. Routine CT head and CT venography were obtained on Toshiba volume and helical CT scanners. MRI and MR venography were performed on a Philips scanner. In all cases there was medial displacement and compression of the posterior fossa dural venous sinuses without intraluminal thrombosis. The epidural hemorrhage was seen tracking along sinus grooves in the occipital bone, peeling the dura containing the sinuses from the calvarium and compressing the sinus, simulating thrombosis on axial CT views. Both venous sinus thrombosis and posterior fossa epidural hemorrhages in children are well-described complications of head trauma. Posterior fossa epidural hemorrhage can mimic a sinus thrombus by compressing and displacing the sinuses. It is important to recognize this pitfall because treatment of a suspected thrombus with anticoagulation can worsen epidural hemorrhage. (orig.)

  1. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Abdomen ...

  2. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Head ...

  3. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Sinuses ...

  4. Utilizing time-lapse micro-CT-correlated bisphosphonate binding kinetics and soft tissue-derived input functions to differentiate site-specific changes in bone metabolism in vivo.

    Science.gov (United States)

    Tower, R J; Campbell, G M; Müller, M; Glüer, C C; Tiwari, S

    2015-05-01

    The turnover of bone is a tightly regulated process between bone formation and resorption to ensure skeletal homeostasis. This process differs between bone types, with trabecular bone often associated with higher turnover than cortical bone. Analyses of bone by micro-computed tomography (micro-CT) reveal changes in structure and mineral content, but are limited in the study of metabolic activity at a single time point, while analyses of serum markers can reveal changes in bone metabolism, but cannot delineate the origin of any aberrant findings. To obtain a site-specific assessment of bone metabolic status, bisphosphonate binding kinetics were utilized. Using a fluorescently-labeled bisphosphonate, we show that early binding kinetics monitored in vivo using fluorescent molecular tomography (FMT) can monitor changes in bone metabolism in response to bone loss, stimulated by ovariectomy (OVX), or bone gain, resulting from treatment with the anabolic bone agent parathyroid hormone (PTH), and is capable of distinguishing different, metabolically distinct skeletal sites. Using time-lapse micro-CT, longitudinal bone turnover was quantified. The spine showed a significantly greater percent resorbing volume and surface in response to OVX, while mice treated with PTH showed significantly greater resorbing volume per bone surface in the spine and significantly greater forming surfaces in the knee. Correlation studies between binding kinetics and micro-CT suggest that forming surfaces, as assessed by time-lapse micro-CT, are preferentially reflected in the rate constant values while forming and resorbing bone volumes primarily affect plateau values. Additionally, we developed a blood pool correction method which now allows for quantitative multi-compartment analyses to be conducted using FMT. These results further expand our understanding of bisphosphonate binding and the use of bisphosphonate binding kinetics as a tool to monitor site-specific changes in bone metabolism in

  5. [Role of PET/CT in primitive non-small cell bronchopulmonary cancer].

    Science.gov (United States)

    Soumia, Fdil; Leila, Achachi; Mohamed, Raoufi; Laila, Herrak; Mustapha, Elftouh

    2017-01-01

    Bronchopulmonary cancer is a real public health problem. Morphological imaging plays a central role in its diagnosis, staging as well as post-therapeutic assessment but it has some limitations. Metabolic imaging is a more recent technique which allows to significantly improve the overall imagery performance. We conducted a retrospective, descriptive and analytical study at the Ibn Sina Hospital and at the Military Hospital of instruction Mohammed V in Rabat over a period of 18 months, between September 2014 and February 2016, in order to evaluate the role of Fluorodeoxyglucose-PET/CT in the staging and restaging of non-small cell bronchopulmonary cancer. Initial staging showed a vast majority of locally advanced and metastatic stages: stage IV (40%), Stage IIIB (36%), Stage IIIA (16%), Stage II (8%). PET-CT allowed to detect new sites which were not initially seen on CT scan in 24 cases: 15 new ganglion sites, 8 new adrenal sites and 6 sites of bone lesions. PET/CT allowed to modify initial tumor stage in 60% of cases: upstaging in 23 patients (46%) and downstaging in 7 patients(14%). The initial stage remained unchanged in 40% of patients. Our study confirms the data from the literature concerning the superiority of PET-CT in comparison with CT scan, but only in the optimization of the non-small cell bronchopulmonary cancer management, in particular in locoregional and distant staging.

  6. CT Imaging of facial trauma. Role of different types of reconstruction. Part I - bones

    International Nuclear Information System (INIS)

    Myga-Porosilo, J.; Sraga, W.; Borowiak, H.; Jackowska, Z.; Kluczewska, E.; Skrzelewski, S.

    2011-01-01

    Background: Injury to the facial skeleton and the adjoining soft tissues is a frequently occurring condition. The main aim of this work was to assess the value of multiplanar and three-dimensional (3D) reconstruction computed tomography (CT) images obtained by using multi-detector row technology in spiral data acquisition in patients with facial skeleton injury. The authors attempted to answer the following questions: Are there particular mechanisms and types of injuries or locations of fractures which can be diagnosed significantly more effectively by conducting additional multiplanar image reconstructions? Do 3D image reconstructions contribute to the diagnostic process, to what extent? Compared to other imaging techniques, is the spiral CT data acquisition a more convenient for the patient and a faster investigation method of diagnosing post-injury lesions involving the facial skeleton? Material/Methods: Sixty-seven patients diagnosed with injury to the facial skeleton were referred for emergent CT scanning. Each patient underwent a CT scan with the use of a GE HiSpeed Qx/i scanner. The scans were conducted with the use of spiral data acquisition technique in the transverse plane. The following secondary image reconstructions were conducted for each patient: a two dimensional (2D) multiplanar reconstruction (MPR), maximum intensity projection (MIP), and 3D volume rendering (VR). Post-injury lesions of the facial skeleton were assessed and the presence of any loose displaced bone fragments was taken into consideration. Results: As far as fracture imaging is concerned, the 2D image reconstruction and volume rendering proved to be the most effective in the majority of locations. 3D image reconstructions proved the most sensitive in most cases of loose displaced bone fragments, except for fine structures such as the ethmoid bone and the inferior orbital wall. Conclusions: 1. Multiplanar computer reconstructions increase the effectiveness of visualisation of

  7. Cardiac CT angiography after coronary artery surgery in children using 64-slice CT scan

    International Nuclear Information System (INIS)

    Marini, Davide; Agnoletti, Gabriella; Brunelle, Francis; Sidi, Daniel; Bonnet, Damien; Ou, Phalla

    2009-01-01

    Objective: The purpose of this study was to compare the diagnostic accuracy of 64-slice CT with that of invasive angiography in the detection of graft and/or coronary angioplasty stenosis in children who had undergone coronary artery surgery. Population and methods: Fifteen consecutive children (8 male and 7 female; age 9.2 ± 6.1 years) underwent 64-slice CT because of chest pain or ECG changes mean 4.8 ± 3.7 years after surgical coronary artery surgery; 10 patients had coronary angioplasty using a patch from the saphenous vein, four had mammary artery bypass, and one had saphenous vein bypass. Six main segments of the coronary arteries and all the bypass graft considered as a single segment were analyzed and compared with invasive angiography used as the reference standard. Results: CT correctly identified the four children with coronary angioplasty and mammary graft lesions that were confirmed by conventional angiography: one patient had a significant stenosis (>50% stenosis) at the mammary bypass graft anastomosis site; three other had non-significant stenosis (<50% stenosis) including a mild lesion of the saphenous vein patch in two patients and a mild lesion at the anastomosis site of the mammary bypass in one. All segments identified as normal by CT in the other 11 children were also found to be normal by conventional angiography. Conclusion: In centers expert in this technique, 64-slice CT scanning is a promising, rapid, and useful diagnostic technique for evaluating both coronary angioplasty and bypass graft lesions in children who had undergone coronary artery surgery.

  8. Displacement characteristics of a piezoactuator-based prototype microactuator with a hydraulic displacement amplification system

    Energy Technology Data Exchange (ETDEWEB)

    Muralidhara [NMAMIT, Nitte (India); Rao, Rathnamala [NITK, Surathkal (India)

    2015-11-15

    In this study, a new piezoactuator-based prototype microactuator is proposed with a hydraulic displacement amplification system. A piezoactuator is used to deflect a diaphragm which displaces a certain volume of hydraulic fluid into a smaller-diameter piston chamber, thereby amplifying the displacement at the other end of the piston. An electro-mechanical model is implemented to estimate the displacement of a multilayer piezoelectric actuator for the applied input voltage considering the hysteresis behavior. The displacement characteristics of the proposed microactuator are studied for triangular actuation voltage signal. Results of the experiments and simulation of the displacement behavior of the stacked piezoactuator and the amplified displacement of the prototype actuator were compared. Experimental results suggest that the mathematical model developed for the new piezoactuator-based prototype actuator is capable of estimating its displacement behavior accurately, within an error of 1.2%.

  9. Displacement characteristics of a piezoactuator-based prototype microactuator with a hydraulic displacement amplification system

    International Nuclear Information System (INIS)

    Muralidhara; Rao, Rathnamala

    2015-01-01

    In this study, a new piezoactuator-based prototype microactuator is proposed with a hydraulic displacement amplification system. A piezoactuator is used to deflect a diaphragm which displaces a certain volume of hydraulic fluid into a smaller-diameter piston chamber, thereby amplifying the displacement at the other end of the piston. An electro-mechanical model is implemented to estimate the displacement of a multilayer piezoelectric actuator for the applied input voltage considering the hysteresis behavior. The displacement characteristics of the proposed microactuator are studied for triangular actuation voltage signal. Results of the experiments and simulation of the displacement behavior of the stacked piezoactuator and the amplified displacement of the prototype actuator were compared. Experimental results suggest that the mathematical model developed for the new piezoactuator-based prototype actuator is capable of estimating its displacement behavior accurately, within an error of 1.2%.

  10. Measuring vulnerability to disaster displacement

    Science.gov (United States)

    Brink, Susan A.; Khazai, Bijan; Power, Christopher; Wenzel, Friedemann

    2015-04-01

    Large scale disasters can cause devastating impacts in terms of population displacement. Between 2008 and 2013, on average 27 million people were displaced annually by disasters (Yonetani 2014). After large events such as hurricane Katrina or the Port-au-Prince earthquake, images of inadequate public shelter and concerns about large scale and often inequitable migration have been broadcast around the world. Population displacement can often be one of the most devastating and visible impacts of a natural disaster. Despite the importance of population displacement in disaster events, measures to understand the socio-economic vulnerability of a community often use broad metrics to estimate the total socio-economic risk of an event rather than focusing on the specific impacts that a community faces in a disaster. Population displacement is complex and multi-causal with the physical impact of a disaster interacting with vulnerability arising from the response, environmental issues (e.g., weather), cultural concerns (e.g., expectations of adequate shelter), and many individual factors (e.g., mobility, risk perception). In addition to the complexity of the causes, population displacement is difficult to measure because of the wide variety of different terms and definitions and its multi-dimensional nature. When we speak of severe population displacement, we may refer to a large number of displaced people, an extended length of displacement or associated difficulties such as poor shelter quality, risk of violence and crime in shelter communities, discrimination in aid, a lack of access to employment or other difficulties that can be associated with large scale population displacement. We have completed a thorough review of the literature on disaster population displacement. Research has been conducted on historic events to understand the types of negative impacts associated with population displacement and also the vulnerability of different groups to these impacts. We

  11. Quality control within the multicentre perfusion CT study of primary colorectal cancer (PROSPeCT): results of an iodine density phantom study

    International Nuclear Information System (INIS)

    Lewis, Maria; Honey, Ian; Goh, Vicky; Beggs, Shaun; Bridges, Andrew; Wayte, Sarah; Clewer, Philip; Davis, Anne; Foy, Trevelyan; Fuller, Karen; George, Jennifer; Higginson, Antony; Iball, Gareth; Mutch, Steve; Neil, Shellagh; Sutton, David; Rivett, Cat; Slater, Andrew; Weir, Nick

    2014-01-01

    To assess the cross-centre consistency of iodine enhancement, contrast-to-noise ratio and radiation dose in a multicentre perfusion CT trial of colorectal cancer. A cylindrical water phantom containing different iodine inserts was examined on seven CT models in 13 hospitals. The relationship between CT number (Hounsfield units, HU) and iodine concentration (milligrams per millilitre) was established and contrast-to-noise ratios (CNRs) calculated. Radiation doses (CTDI vol , DLP) were compared across all sites. There was a linear relationship between CT number and iodine density. Iodine enhancement varied by a factor of at most 1.10, and image noise by at most 1.5 across the study sites. At an iodine concentration of 1 mg ml -1 and 100 kV, CNRs ranged from 3.6 to 4.8 in the 220-mm phantom and from 1.4 to 1.9 in the 300-mm phantom. Doses varied by a factor of at most 2.4, but remained within study dose constraints. Iterative reconstruction algorithms did not alter iodine enhancement but resulted in reduced image noise by a factor of at most 2.2, allowing a potential dose decrease of at most 80 % compared to filtered back projection (FBP). Quality control of CT performance across centres indicates that CNR values remain relatively consistent across all sites, giving acceptable image quality within the agreed dose constraints. (orig.)

  12. Quality control within the multicentre perfusion CT study of primary colorectal cancer (PROSPeCT): results of an iodine density phantom study

    Energy Technology Data Exchange (ETDEWEB)

    Lewis, Maria; Honey, Ian [Trust, Medical Physics Department, Guy' s and St. Thomas' NHS Foundation, London (United Kingdom); Goh, Vicky [King' s College London, St Thomas' Hospital, Division of Imaging Sciences and Biomedical Engineering, London (United Kingdom); Beggs, Shaun [Bradford Teaching Hospitals NHS Foundation Trust, Radiation Physics Services, Bradford (United Kingdom); Bridges, Andrew; Wayte, Sarah [Radiology Physics University Hospitals Coventry and Warwickshire NHS Trust, Coventry (United Kingdom); Clewer, Philip [Medical Physics Department, University Hospital Southampton NHS Foundation Trust, Southampton (United Kingdom); Davis, Anne [Portsmouth Hospitals NHS Trust, Medical Physics Department, Portsmouth (United Kingdom); Foy, Trevelyan [Royal Cornwall Hospital NHS Trust, Medical Physics Department, Truro (United Kingdom); Fuller, Karen [Sheffield Teaching Hospitals NHS Foundation Trust, Medical Physics Department, Sheffield (United Kingdom); George, Jennifer [University Hospital of North Staffordshire NHS Trust, Medical Physics Department, Stoke-on-Trent (United Kingdom); Higginson, Antony [Portsmouth Hospitals NHS Trust, Department of Radiology, Portsmouth (United Kingdom); Iball, Gareth [Leeds Teaching Hospitals NHS Trust, Department of Medical Physics and Engineering, Leeds (United Kingdom); Mutch, Steve [Oxford University Hospitals NHS Trust, Radiation Physics and Protection Department, Oxford (United Kingdom); Neil, Shellagh; Sutton, David [NHS Tayside, Medical Physics Department, Dundee, Scotland (United Kingdom); Rivett, Cat [Plymouth Hospitals NHS Trust, Clinical and Radiation Physics, Plymouth (United Kingdom); Slater, Andrew [Oxford University Hospitals NHS Trust, Department of Radiology, Oxford (United Kingdom); Weir, Nick [Queen' s Medical Research Institute, Clinical Research Imaging Centre, Edinburgh, Scotland (United Kingdom); Collaboration: on behalf of the PROSPeCT Investigators

    2014-09-15

    To assess the cross-centre consistency of iodine enhancement, contrast-to-noise ratio and radiation dose in a multicentre perfusion CT trial of colorectal cancer. A cylindrical water phantom containing different iodine inserts was examined on seven CT models in 13 hospitals. The relationship between CT number (Hounsfield units, HU) and iodine concentration (milligrams per millilitre) was established and contrast-to-noise ratios (CNRs) calculated. Radiation doses (CTDI{sub vol}, DLP) were compared across all sites. There was a linear relationship between CT number and iodine density. Iodine enhancement varied by a factor of at most 1.10, and image noise by at most 1.5 across the study sites. At an iodine concentration of 1 mg ml{sup -1} and 100 kV, CNRs ranged from 3.6 to 4.8 in the 220-mm phantom and from 1.4 to 1.9 in the 300-mm phantom. Doses varied by a factor of at most 2.4, but remained within study dose constraints. Iterative reconstruction algorithms did not alter iodine enhancement but resulted in reduced image noise by a factor of at most 2.2, allowing a potential dose decrease of at most 80 % compared to filtered back projection (FBP). Quality control of CT performance across centres indicates that CNR values remain relatively consistent across all sites, giving acceptable image quality within the agreed dose constraints. (orig.)

  13. Preliminary results on the role of PET/CT in initial staging, restaging, and management of lung cancer

    Energy Technology Data Exchange (ETDEWEB)

    Malamitsi, J. [Department of PET/CT, Diagnostic and Therapeutic Center of Athens, Hygeia, Athens (Greece): Department of Medical Physics, Medical School, University of Athens (Greece)]. E-mail: j.malamitsi@yahoo.gr; Valotassiou, B. [Department of PET/CT, Diagnostic and Therapeutic Center of Athens, Hygeia, Athens (Greece); Iliadis, K. [Thoracic Surgical Department, Diagnostic and Therapeutic Center of Athens, Hygeia, Athens (Greece); Kosmidis, P. [2nd Medical Oncology Department, Diagnostic and Therapeutic Center of Athens, Hygeia, Athens (Greece); Laspas, F. [Department of PET/CT, Diagnostic and Therapeutic Center of Athens, Hygeia, Athens (Greece); Vasilaki, M. [Oncologist, Diagnostic and Therapeutic Center of Athens, Hygeia, Athens (Greece); Pipini, E. [Thoracic Medicine Clinic, Diagnostic and Therapeutic Center of Athens, Hygeia, Athens (Greece); Petounis, A. [1st Internal Medicine and Oncology Department, Diagnostic and Therapeutic Center of Athens, Hygeia, Athens (Greece); Gogou, L. [Department of PET/CT, Diagnostic and Therapeutic Center of Athens, Hygeia, Athens (Greece); Pagou, M. [Department of PET/CT, Diagnostic and Therapeutic Center of Athens, Hygeia, Athens (Greece); Dalianis, K. [Department of PET/CT, Diagnostic and Therapeutic Center of Athens, Hygeia, Athens (Greece); Efthimiadou, R. [Department of PET/CT, Diagnostic and Therapeutic Center of Athens, Hygeia, Athens (Greece); Andreou, J. [Department of PET/CT, Diagnostic and Therapeutic Center of Athens, Hygeia, Athens (Greece)

    2006-12-20

    Aim: To determine true-positive and true-negative rates of PET/CT studies in the staging of lung cancer as compared with conventional imaging (CT and bone scan and occasionally MRI) and the impact of PET/CT on the treatment strategy in patients with lung cancer. Materials and method: Twenty patients (21 studies) with known or suspected lung cancer (14 patients with non-small-cell lung cancer (NSCLC), three patients with small-cell lung cancer (SCLC), three patients with solitary pulmonary nodule underwent initial staging (seven studies) or restaging (14 studies) with combined FDG PET and CT scans on a PET/CT tomograph. PET/CT images were evaluated separately by two nuclear medicine physicians and two radiologists specialized on PET, CT, and MRI. Histology results and a more than 6 months follow-up served as the reference standards. Results: Accurate diagnosis was achieved on 16 studies. Site-by-site analysis gave the following results: 16 true-positive sites (seven on histology, nine on >6 months follow-up), six true-negative sites (two on histology, four on >6 months follow-up). On PET/CT, six patients were correctly down-staged, three patients were correctly upstaged and seven patients were diagnosed correctly as being on the same stage (2/7 with increase of extent of disease, 5/7 with the same extent of disease). One patient was falsely upstaged and three patients were falsely down-staged. On the basis of PET/CT results, change of management was induced in six patients, while in 14 patients there was no change induced. In five cases PET/CT was partially accurate: on site-by-site analysis, four sites proved true positive (on histology), one site false positive (on histology), and four sites false negative (one on histology, three on >6 months follow-up). Conclusion: In our early experience, PET/CT contributed significantly to correct staging and management of patients with lung cancer.

  14. Preliminary results on the role of PET/CT in initial staging, restaging, and management of lung cancer

    International Nuclear Information System (INIS)

    Malamitsi, J.; Valotassiou, B.; Iliadis, K.; Kosmidis, P.; Laspas, F.; Vasilaki, M.; Pipini, E.; Petounis, A.; Gogou, L.; Pagou, M.; Dalianis, K.; Efthimiadou, R.; Andreou, J.

    2006-01-01

    Aim: To determine true-positive and true-negative rates of PET/CT studies in the staging of lung cancer as compared with conventional imaging (CT and bone scan and occasionally MRI) and the impact of PET/CT on the treatment strategy in patients with lung cancer. Materials and method: Twenty patients (21 studies) with known or suspected lung cancer (14 patients with non-small-cell lung cancer (NSCLC), three patients with small-cell lung cancer (SCLC), three patients with solitary pulmonary nodule underwent initial staging (seven studies) or restaging (14 studies) with combined FDG PET and CT scans on a PET/CT tomograph. PET/CT images were evaluated separately by two nuclear medicine physicians and two radiologists specialized on PET, CT, and MRI. Histology results and a more than 6 months follow-up served as the reference standards. Results: Accurate diagnosis was achieved on 16 studies. Site-by-site analysis gave the following results: 16 true-positive sites (seven on histology, nine on >6 months follow-up), six true-negative sites (two on histology, four on >6 months follow-up). On PET/CT, six patients were correctly down-staged, three patients were correctly upstaged and seven patients were diagnosed correctly as being on the same stage (2/7 with increase of extent of disease, 5/7 with the same extent of disease). One patient was falsely upstaged and three patients were falsely down-staged. On the basis of PET/CT results, change of management was induced in six patients, while in 14 patients there was no change induced. In five cases PET/CT was partially accurate: on site-by-site analysis, four sites proved true positive (on histology), one site false positive (on histology), and four sites false negative (one on histology, three on >6 months follow-up). Conclusion: In our early experience, PET/CT contributed significantly to correct staging and management of patients with lung cancer

  15. CT findings of spondylolysis and spondylolisthesis

    Energy Technology Data Exchange (ETDEWEB)

    Gong, Jae Chul; Kim, Hyung Jin; Kim, Jae Hyoung; Shin, Hyung Jin; Ha, Choong Kun; Lim, Byeong Hoon; Chung, Sung Hoon [Gyeong Sang National University College of Medicine, Chinju (Korea, Republic of); Kim, Dong Kyu [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1990-12-15

    Spondylolysis is a common condition, but CT findings have been paid relatively scanty attention in journal publication. The authors reviewed lumbar spine CT of 42 patients who were diagnosed as spondylosis and/or spondylolisthesis in Gyeong Sang National University Hospital. The results were as follows. 1. In 27 cases of spondylolysis, it most frequently occurred at L5 (55.5%) with 88.3% of bilaterality. The defeat of the pars interarticularis was most clearly visible on the slice at or just above the neural foramen. The appearance of the defect had a horizontal plane(88.9%), an irregular surface(85.1%), a non sclerotic margin(88.9%), and a medial proturbance of the medial aspect of the bone just anterior to the defect(77.8%). Spondylolisthesis was associated in 20 of 27 cases(74%), which was demonstrated as an elongation of the anteroposterior diameter of the spinal canal and a pseudobulging disk at defect level in all cases. The degree of the anterior displacement was Grade I in fourteen(55.6%) and Grade II in five(18.7%). 2. Degenerative spondylolisthesis was found in 18 cases and most frequently occurred at L4-5 level(83.3%). The characteristic findings were a vertically-oriented joint plane(66.7%), a posterior displacement of the anterior facet with reference to the posterior facet(50%), bony spurs in the anterior facet(94.1%), a vacuum facet joint(55.6%), and an increased facet joint distance(50%). 3. Spinal stenosis and disk herniation were two most frequent associated abnormalities. They were found at a rate 44.4% and 14.8% in spondylolysis and at a rate 72.2% and 33.3% in degenerative spondylolisthesis. In cases of disk herniation, it frequently occurred just above the level of the defect(2/4) in spondylolysis, in contrast to degenerative spondylolisthesis in which it was most frequent at the same level(4/6). In conclusion, CT must be the highly accurate method for diagnosing and evaluating spondylolysis and all types of spondylolisthesis.

  16. CT findings of spondylolysis and spondylolisthesis

    International Nuclear Information System (INIS)

    Gong, Jae Chul; Kim, Hyung Jin; Kim, Jae Hyoung; Shin, Hyung Jin; Ha, Choong Kun; Lim, Byeong Hoon; Chung, Sung Hoon; Kim, Dong Kyu

    1990-01-01

    Spondylolysis is a common condition, but CT findings have been paid relatively scanty attention in journal publication. The authors reviewed lumbar spine CT of 42 patients who were diagnosed as spondylosis and/or spondylolisthesis in Gyeong Sang National University Hospital. The results were as follows. 1. In 27 cases of spondylolysis, it most frequently occurred at L5 (55.5%) with 88.3% of bilaterality. The defeat of the pars interarticularis was most clearly visible on the slice at or just above the neural foramen. The appearance of the defect had a horizontal plane(88.9%), an irregular surface(85.1%), a non sclerotic margin(88.9%), and a medial proturbance of the medial aspect of the bone just anterior to the defect(77.8%). Spondylolisthesis was associated in 20 of 27 cases(74%), which was demonstrated as an elongation of the anteroposterior diameter of the spinal canal and a pseudobulging disk at defect level in all cases. The degree of the anterior displacement was Grade I in fourteen(55.6%) and Grade II in five(18.7%). 2. Degenerative spondylolisthesis was found in 18 cases and most frequently occurred at L4-5 level(83.3%). The characteristic findings were a vertically-oriented joint plane(66.7%), a posterior displacement of the anterior facet with reference to the posterior facet(50%), bony spurs in the anterior facet(94.1%), a vacuum facet joint(55.6%), and an increased facet joint distance(50%). 3. Spinal stenosis and disk herniation were two most frequent associated abnormalities. They were found at a rate 44.4% and 14.8% in spondylolysis and at a rate 72.2% and 33.3% in degenerative spondylolisthesis. In cases of disk herniation, it frequently occurred just above the level of the defect(2/4) in spondylolysis, in contrast to degenerative spondylolisthesis in which it was most frequent at the same level(4/6). In conclusion, CT must be the highly accurate method for diagnosing and evaluating spondylolysis and all types of spondylolisthesis

  17. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... view of the body's interior. Refinements in detector technology allow nearly all CT scanners to obtain multiple ... at these links. About Us | Contact Us | FAQ | Privacy | Terms of Use | Links | Site Map Copyright © 2018 ...

  18. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... view of the body's interior. Refinements in detector technology allow nearly all CT scanners to obtain multiple ... at these links. About Us | Contact Us | FAQ | Privacy | Terms of Use | Links | Site Map Copyright © 2018 ...

  19. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... view of the body's interior. Refinements in detector technology allow nearly all CT scanners to obtain multiple ... at these links. About Us | Contact Us | FAQ | Privacy | Terms of Use | Links | Site Map Copyright © 2018 ...

  20. The value of different imaging methods on classification in displaced proximal humeral fractures

    International Nuclear Information System (INIS)

    Cai Jingyu; Zhu Qingsheng

    2004-01-01

    Objective: To investigate the influence of common X-ray, two-dimensional computed tomography (2D-CT), spiral computed tomography (SCT), and three-dimensional (3-D) reconstruction on the classification in displaced proximal humeral fractures. Methods: Three groups were divided on the basis of various imaging methods, including group A (common X-ray), group B (common X-ray and 2D-CT), and group C (3-D reconstruction of SCT and 2D-SCT). 46 cases of displaced proximal humeral fractures were classified with Neer system. The true rate of fracture classification by use of three methods was compared with each other, and clinical significance of SCT and 3-D reconstruction was evaluated. Results: Based on operation, 46 cases of displaced proximal humeral fractures in group A included 26 cases of Neer two-part fractures, 13 cases of three-part fractures, and 7 cases of four-part fractures. The true cases of common X-ray were 22 in Neer two-part fractures and 8 in three and four-part fractures, there was significant difference between Neer two-part fractures and Neer three and four-part fractures (P<0.05); 18 cases of proximal humeral fractures in group B included 3 cases of Neer two-part fractures, 9 cases of three-part fractures, and 6 cases of four-part fractures. The true cases of common X-ray and 2D-CT were 7 in Neer three and four-part fractures. 10 cases of proximal humeral fractures in group C included 1 case of Neer two-part fracture, 5 cases of three-part fractures, and 4 cases of four-part fractures. The true cases of 3-D reconstruction, MPR of SCT, and 2D-SCT were 8 in Neer three and four-part fractures. With regard to the true cases of the classification in Neer three and four-part fractures, there was significant difference in three groups and between group A and group C (P<0.05). All SCT and 3-D reconstruction played an important role in the treatment of proximal humeral fractures. Conclusion: Series of good quality X-ray examinations were the first imaging

  1. Fiber-optic displacement sensors on the Hunters Trophy UGT impulse gauge experiments

    Energy Technology Data Exchange (ETDEWEB)

    Green, R.E.L.; Poutiatine, A.I.

    1995-03-01

    As part of a program to develop gauges for measurement of various mechanical properties in hostile environments, the authors fielded purely optical displacement sensors at the ends of long fiber-optic cables as supplements to the regular displacement sensors of four impulse gauges fielded as part of a materials study on the Hunters Trophy underground effects test at the Nevada Test Site. These fiber-optic sensor systems and their performance on the Hunters Trophy test are described in this report.

  2. Crustal displacements in Greenland caused by ice mass variability

    DEFF Research Database (Denmark)

    Nielsen, Karina

    rates indicates, that the modeled elastic displacements are well captured. Based on this analysis, the GIA rates are estimated to -1 ± 0.6 mm/yr at KELY, 2 ± 0.7 mm/yr at SCOR, and 0.5 ± 0.5 mm/yr at QAQ1. At the sites KULU and THU2 the elastic displacement rates could not be accurately estimated...... modeled and removed. Over a period of a few decades, the GIA rate is assumed to be constant. Hence, changes in the observed rate results from the present-day changes. Here, mass change grids, derived from Ice, Cloud,and land Elevation Satellite (ICESat) data from three overlapping time spans are used...

  3. Resonant neutron-induced atomic displacements

    Energy Technology Data Exchange (ETDEWEB)

    Elmaghraby, Elsayed K., E-mail: e.m.k.elmaghraby@gmail.com

    2017-05-01

    Highlights: • Neutron induced atomic displacements was investigated based on scattering of energy of neutron. • Model for cascade function (multiplication of displacements with increasing energy transfer) was proposed and justified. • Parameterizations for the dpa induced in all elements were performed. • Table containing all necessary parameters to calculate the displacement density induced by neutron is given. • Contribution of non resonance displacement and resonant-neutron induced displacements are distinguished. - Abstract: A model for displacement cascade function was modified to account for the continuous variation of displacement density in the material in response to neutron exposure. The model is based on the Gaussian distribution of displacement energies of atoms in a material. Analytical treatment for moderated epithermal neutron field was given in which the displacement density was divided into two terms, discrete-resonance term and continuum term. Calculation are done for all isotopes using ENDF/B VII.1 data files and temperature dependent cross section library. Weighted elemental values were reported a fitting was performed to obtain energy-dependent formula of displacement density and reduce the number of parameters. Results relevant the present specification of the cascade function are tabulated for each element to enable calculation of displacement density at any value of displacement energy in the between 5 eV and 55 eV.

  4. Usefulness of low dose oral contrast media in 18F-FDG PET/CT

    International Nuclear Information System (INIS)

    An, Young Sil; Yoon, Joon Kee; Hong, Seon Pyo; Joh, Chul Woo; Yoon, Seok Nam

    2006-01-01

    The standard protocol using large volume of oral contrast media may cause gastrointestinal discomfort and contrast-related artifacts in PET/CT. The aim of this study was to evaluate the usefulness of low dose oral contrast in 18 F-FDG PET/CT. We retrospectively reviewed the whole-body PET/CT images in a total of 435 patients. About 200 ml of oral contrast agent (barium sulfate) was administered immediately before injection of 18 F-FDG. The FDG uptake of intestines was analyzed by visual and semi-quantitative method on transaxial, coronal and saggital planes. Seventy (16%, 113 sites) of 435 images showed high FDG uptake (peak SUV > 4); 50 (74%, 84 sites) with diffuse and 20 (26%, 29 sites) with focal uptake. The most commonly delivered site of oral contrast media was small bowel (n = 27, 39%). On PET/CT images, FDG uptake coexisted with oral contrast media in 26 patients (54%, 38 sites) with diffuse pattern and 9 (45%, 9 sites) with focal pattern, and by sites, those were 38 (45%) and 9 (31%), respectively. In small bowel regions, the proportion of coexistence reached as high as 61% (29/47 sites). A visual analysis of available non-attenuation corrected PET images of 27 matched regions revealed no contrast-related artifact. We concluded that the application of low dose contrast media could be helpful in the evaluation of abdominal uptake in the FDG PET/CT image

  5. Diagnostic Performance of F-18 FDG PET/CT in Patients with Cancer of Unknown Primary: Additional Benefit over CT-Based Conventional Work up

    Directory of Open Access Journals (Sweden)

    Mehrdad Bakhshayeshkaram

    2016-01-01

    Full Text Available Background: In the era of well-developed site-specific treatment strategies in cancer, identification of occult primary is of paramount importance in CUP patients. Furthermore, exact determination of the extent of the disease may help in optimizing treatment planning. The aim of the present study was to investigate additional value of F-18 FDG PET/CT in patients with cancer of unknown primary (CUP as an appropriate imaging tool in early phase of initial standard work up.Materials and Methods: Sixty-two newly diagnosed CUP patients with inconclusive diagnostic CT scan of chest, abdomen and pelvis referring for F-18 FDG PET/CT were enrolled in this study. Standard of reference was defined as histopathology, other diagnostic procedures and a 3-month formal clinical follow up. The results of PET/CT were categorized as suggestion for primary site and additional metastasis and classified as true positive, false positive, false negative and true negative. The impact of additional metastasis revealed by F-18 FDG PET/CT on treatment planning and the time contribution of F-18 FDG PET/CT in diagnostic pathway was investigated.Results: Sixty-two patients with mean age of 62 (30 men, 32 women, PET/CT correctly identified primary origin in 32% with false positive rate of 14.8%. No primary lesion was detected after negative PET/CT according to standard of reference. Sensitivity, Specificity and accuracy were 100%, 78% and 85%, respectively. Additional metastatic site was found in 56% with 22% impact on treatment planning. Time contribution for PET/CT was 10% of total diagnostic pathway.Conclusion: Providing higher detection rate of primary origin with excellent diagnostic performance, shortening the diagnostic pathway and improving treatment planning, F-18 FDG PET/CT may play a major role in diagnostic work up of CUP patients and may be recommended as an alternative imaging tool in early phase of investigation.

  6. Detection of skeletal muscle metastasis: torso FDG PET-CT versus contrast-enhanced chest or abdomen CT.

    Science.gov (United States)

    So, Young; Yi, Jeong Geun; Song, Inyoung; Lee, Won Woo; Chung, Hyun Woo; Park, Jeong Hee; Moon, Sung Gyu

    2015-07-01

    Skeletal muscle metastasis (SMM) in cancer patients has not been sufficiently evaluated regarding prevalence and proper method of detection. To determine the prevalence of SMM and compare the diagnostic competencies for SMM of torso F-18 fluorodeoxyglucose (FDG) positron emission tomography-computed tomography (PET-CT) and contrast-enhanced chest or abdomen CT. We investigated 18,225 PET-CT studies of 6359 cancer patients performed from 2005 to 2012. The PET-CT studies describing potential SMM were retrieved and the corresponding medical records were reviewed. The gold standard for SMM was histopathologically-proven SMM or imaging study-based disease progression. The detectability of SMM was compared between PET-CT and contrast-enhanced CT. Twenty-six patients had 84 SMM lesions, representing a SMM prevalence of 0.41%. Lung cancer was the most common SMM-associated malignancy (54%) and the gluteal/pelvic girdle muscle was the most frequently involved SMM site (37%). All 84 SMM lesions were visualized on PET-CT (100%). Of these PET-CT positive 84 SMM lesions, 51 lesions were in the CT field of view (FOV) (61%), whereas 33 lesions were out of the CT FOV (39%). Among these 51 lesions, 17 lesions showed rim-enhancing nodules/masses (33%), eight lesions showed homogeneously enhancing nodules (16%), three lesions showed heterogeneously enhancing nodules (6%), and 23 SMM lesions (45%) were non-diagnostic by CT. All 51 SMM lesions within CT FOV were detected on PET-CT (100%), whereas only 28 were visualized on CT (54.9%), resulting in a significant difference (P SMM was revealed by PET-CT. The prevalence of SMM was as low as 0.41% in the current large cohort of cancer patients. Torso PET-CT was a more competent modality than contrast-enhanced CT in the detection of SMM. © The Foundation Acta Radiologica 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  7. Evaluation on temporal bone CT findings of cholesteatoma

    International Nuclear Information System (INIS)

    Lee, Kun Won; Lee, Nam Joon; Kang, Eun Young; Chung, Kyoo Byung; Suh, Won Hyuck

    1989-01-01

    Cholesteatomas are thought to result from ingrowth of keratinizing squamous epithelium from external ear to middle ear. The cholesteatomas are usually diagnosed by clinical symptoms and signs, otoscopy, and plain radiograms. But various view points are emphasized radiologically before operation, leading to examine by computed tomography (CT), especially in complicated cases. We retrospectively reviewed the CT findings of cholesteatomas in 25 surgically proven cases during the period from May, 1983 to Aug, 1988. The results were as follows: 1. Most cholesteatomas showed soft tissue mass and bony erosion of ossicles (88%), attic wall and mastoid antrum (84%) on temporal bone CT scan. 2. The CT members of cholesteatomas ranged from 25 to 50 HU (avg. 33 HU). 3. Involved sites were attic (16%), antrum (28%), and both attic and antrum (56%). Other sites were middle ear cavity and external auditory canal. 4. Extra-tympanomastoid extension of cholesteatoma was intracranial abscess (8%), exposure of dural sinus (8%), and extension along with neck (4%)

  8. Effects of corticopuncture (CP) and low-level laser therapy (LLLT) on the rate of tooth movement and root resorption in rats using micro-CT evaluation.

    Science.gov (United States)

    Suzuki, Selly Sayuri; Garcez, Aguinaldo Silva; Reese, Patricia Oblitas; Suzuki, Hideo; Ribeiro, Martha Simões; Moon, Won

    2018-05-01

    The aim of this study was to compare the rate of tooth displacement, quantity of root resorption, and alveolar bone changes in five groups: corticopuncture (CP), low-level laser therapy (LLLT), CP combined with LLLT (CP + LLLT), control (C), and negative control (NC). A total of 60 half-maxilla from 30 male Wistar rats (10 weeks old) were divided randomly into five groups: three (CP, LLLT, and CP + LLLT) test groups with different stimulation for accelerated-tooth-movement (ATM), one control (C) group, and one negative control (NC) group with no tooth movement. Nickel-titanium coil springs with 50 g of force were tied from the upper left and right first molars to micro-implants placed behind the maxillary incisors. For the CP and CP + LLLT groups, two perforations in the palate and one mesially to the molars were performed. For the LLLT and CP + LLLT groups, GaAlAs diode laser was applied every other day for 14 days (810 nm, 100 mW, 15 s). The tooth displacements were measured directly from the rat's mouth and indirectly from microcomputer (micro-CT) tomographic images. Bone responses at the tension and compression sites and root resorption were analyzed from micro-CT images. The resulting alveolar bone responses were evaluated by measuring bone mineral density (BMD), bone volume fraction (BV/TV), and trabecular thickness (TbTh). Root resorption crater volumes were measured on both compression and tension sides of mesial and distal buccal roots. The tooth displacement in the CP + LLLT group was the greatest when measured clinically, followed by the CP, LLLT, and control groups (C and NC), respectively (p CP and CP + LLLT groups compared to the LLLT and control groups. The BMD, BV/TV, and TbTh values were lower at the compression side and higher at the tension side for all three test groups compared to the control group. The root resorption crater volume of the distal buccal root was higher in the control group, followed by CP, LLLT

  9. Job Displacement and Crime

    DEFF Research Database (Denmark)

    Bennett, Patrick; Ouazad, Amine

    theory of crime. Marital dissolution is more likely post-displacement, and we find small intra-family externalities of adult displacement on younger family members’ crime. The impact of displacement on crime is stronger in municipalities with higher capital and labor income inequalities....

  10. Small leiomyosarcoma of the renal capsule: CT findings

    Energy Technology Data Exchange (ETDEWEB)

    Roy, C.; Pfleger, D.; Tuchmann, C.; Guth, S.; Gangi, A. [Department of Radiology B, Chirurgie A, Hopitaux Universitaires de Strasbourg (France); Lindner, V. [Department of Pathology, Hopitaux Universitaires de Strasbourg (France); Morel, M. [Clinique Saint-Francois, 1, rue Colome, F-67 500 Haguenau (France)

    1998-03-01

    Three unusual cases of small-size leiomyosarcoma of the perirenal space were studied with CT. The renal capsule has been proved to be the origin of this type of tumor. A CT examination is accurate in suggesting the site of origin and excluding a renal cell carcinoma. However, unless evidence of invasion is noted, it is impossible on CT features to discriminate leiomyosarcoma from a benign leiomyoma. (orig.) With 3 figs., 21 refs.

  11. CT simulation in nodal positive breast cancer

    International Nuclear Information System (INIS)

    Horst, E.; Schuck, A.; Moustakis, C.; Schaefer, U.; Micke, O.; Kronholz, H.L.; Willich, N.

    2001-01-01

    Background: A variety of solutions are used to match tangential fields and opposed lymph node fields in irradiation of nodal positive breast cancer. The choice is depending on the technical equipment which is available and the clinical situation. The CT simulation of a non-monoisocentric technique was evaluated in terms of accuracy and reproducibility. Patients, Material and Methods: The field match parameters were adjusted virtually at CT simulation and were compared with parameters derived mathematically. The coordinate transfer from the CT simulator to the conventional simulator was analyzed in 25 consecutive patients. Results: The angles adjusted virtually for a geometrically exact coplanar field match corresponded with the angles calculated for each set-up. The mean isocenter displacement was 5.7 mm and the total uncertainty of the coordinate transfer was 6.7 mm (1 SD). Limitations in the patient set-up became obvious because of the steep arm abduction necessary to fit the 70 cm CT gantry aperture. Required modifications of the arm position and coordinate transfer errors led to a significant shift of the marked matchline of >1.0 cm in eight of 25 patients (32%). Conclusion: The virtual CT simulation allows a precise and graphic definition of the field match parameters. However, modifications of the virtual set-up basically due to technical limitations were required in a total of 32% of cases, so that a hybrid technique was adapted at present that combines virtual adjustment of the ideal field alignment parameters with conventional simulation. (orig.) [de

  12. CT and MRI post-processing reconstructions in maxillo-facial trauma

    International Nuclear Information System (INIS)

    Olszycki, M.; Grzelak, P.; Stanczyk, L.; Kozakiewicz, M.; Arkuszewski, P.

    2004-01-01

    The aim of the study is to evaluate the reliability of CT and MR imaging and their post-processing reconstructions in the cases of facial trauma. CT studies were performed in 34 patients: 13 suspected of sinus fractures, 20 with orbital fractures and 1 with broken supraorbital bone fragment. MR imaging was also performed in 16 of these patients. The CT data were reconstructed in the 2D and 3D mode. The CT and MR images were digitally fused using an own program. The CT and MR images, their reconstructions and their fusion were evaluated according to the quality of visualization of a pathological lesions. Surgery was the method of reference. The reconstructed CT images allowed to recognize properly maxillary-oral fenestration in 5 cases. In 20 patients with orbital fracture, CT 3D reformations visualized well the morphology of the fissure. In 13 of these patients,the small bone fragments and orbital soft tissues prolapsed towards the maxillary sinus were depicted. Among the 16 patients who underwent MR examination, in 6 cases we revealed dislocation of the inferior rectus muscle towards the sinus, whereas in 9 cases MR images clearly excluded this pathology. In 1 patient, the digitally fused CT/MR images allowed to determine the actual position of small bone fragment within the muscle. In 1 patient with broken supraorbital bone fragment, evaluation of the 3D model allowed to exclude communication with intracranial space. In the next 8 patients with maxillo-zygomatic injures, the CT reconstructions did not support the diagnosis. The surgery correlated well with the post-processing CT and CT/MR fused images, contrary to the original CT ones which often were diagnostically insufficient. Spiral CT 2D and 3D-reconstructed images of the face allow to depict clearly the anatomical spatial relationships and the position, course and displacement of fractured fragments; thus, they support the surgery. The MR images of these patients reveal soft tissues clearly. The digital

  13. Evaluation of diagnostic and operative problems in basal meningioma by two-plane CT and angiography

    International Nuclear Information System (INIS)

    Inoue, Hiroshi; Tamura, Masaru; Kawafuchi, Jun-ichi

    1982-01-01

    Basal meningiomas were investigated using two-plane computed tomography (CT) with an ordinary section combined with a reverse section to ascertain the precise site of the origin, size, extension, properties and relation to adjacent tissue. Furthermore, with information obtained from angiography, operative difficulty and operative indications were investigated, to determine a therapeutic policy taking neurofunctional prognosis into consideration. The factors directly affecting the operative difficulty were the large size of the tumor, deformity of the hypothamus and brain stem, supratentorial or infratentorial extension, bone erosion, calcification of the tumor, direct effect on the major vessels and high vascularity. It is considered to be difficult or impossible to perform operations in cases accompanied by more than three of these factors and, in the case of posterior fossa tumors, more than two. Tumor density, extent of enhancement, perifocal low-density, ventricular dilatation, transtentorial herniation, brain or brain stem displacement, bone erosion on CT scans as well as tumor vascularity, feeding arteries, and changes in the major vessels on angiograms were also studied, and therapeutic problems as well as their countermeasures regarding these findings were discussed. It is emphasized that obtaining more accurate information concerning the preoperative state is the first step towards the improvement of therapeutic results in basal meningiomas. (author)

  14. Spect-CT and PET: CT in the management of differentiated thyroid cancer

    International Nuclear Information System (INIS)

    Khan, Shoukat H.

    2007-01-01

    Full text: With the advancement and evolution in medical technology notably imaging there has been a sea change in the overall management strategy of most of the cancers of human body. The present day functional, imaging with PET and MRI enables us to pick up a tumour at its cellular stage. Molecular imaging and nanotechnology have further added to this expanding armamentarium of cancer imaging and treatment. Thyroid cancer is one such cancer where the cutting edge biotechnology has dramatically changed the management profile of a disease. Thyroid cancer can safely be classified as one of the cancers which if optimally managed is curable. Hybrid and fusion imaging like SPECT-CT and PET-CT with their superior sensitivity and specificity have greatly improved the accuracy of disease detection and reduced drastically the false positive disease sites. Disease not detected by conventional planar imaging can now be detected and also anatomically localized using hybrid imaging modalities of SPECT-CT and PET-CT. An accurate detection and precise localization improves image interpretation and a treatment optimization in the curable cancer of thyroid

  15. Pulmonary langerhans cell histiocytosis in adults: high-resolution CT - pathology comparisons and evolutional changes at CT

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyo Jin; Lee, Ho Yun; Kim, Tae Sung [Sungkyunkwan University School of Medicine, Department of Radiology and Center for Imaging Science, Samsung Medical Center, Seoul (Korea, Republic of); Lee, Kyung Soo [Sungkyunkwan University School of Medicine, Department of Radiology and Center for Imaging Science, Samsung Medical Center, Seoul (Korea, Republic of); Samsung Medical Center, Department of Radiology, Seoul (Korea, Republic of); Johkoh, Takeshi [Kinki Central Hospital of Mutual Aid Association of Public School Teachers, Department of Radiology, Hyoko (Japan); Tomiyama, Noriyuki [Osaka University Graduate School of Medicine, Department of Radiology, Osaka (Japan); Han, Joungho [Sungkyunkwan University School of Medicine, Department of Pathology, Samsung Medical Center, Seoul (Korea, Republic of)

    2011-07-15

    To compare high-resolution (HR) CT and histopathological findings and to evaluate serial CT findings in pulmonary Langerhans cell histiocytosis (PLCH). We reviewed CT of lung lesions in 27 adults (M:F = 20:7, mean age, 41 {+-} 12.3 years) with PLCH. After evaluating lung abnormalities including nodules, micronodules, thick-walled, thin-walled, and bizarre-shaped cysts and reticulation, observers compared CT findings obtained at lung biopsy sites with histopathological findings. The final CT was compared with the initial CT to determine disease extent changes. The most frequently observed patterns of lung abnormalities were micronodules (n = 24, 89%), thick-walled (n = 22, 82%), and thin-walled (n = 22, 82%) cysts. Even thin-walled and bizarre cysts harboured active inflammatory Langerhans cell sheets and eosinophils in their walls. In thin-walled cysts, we noted pericystic inflammatory cell infiltrations along the alveolar walls, as well as pericystic emphysema. Thin-walled or bizarre cysts demonstrated a tendency to coalesce with surrounding cysts via their cystic wall destruction. Fourteen (52%) patients showed improvement and nine (33%) showed progressing disease. More than half of patients with pulmonary PLCH show improvement at follow-up CT. Even thin-walled cysts harbour active inflammatory cells on histopathology and exhibit improvement at follow-up CT. (orig.)

  16. High FDG uptake areas on pre-radiotherapy PET/CT identify preferential sites of local relapse after chemoradiotherapy for locally advanced oesophageal cancer

    Energy Technology Data Exchange (ETDEWEB)

    Calais, Jeremie; Lemarignier, Charles; Vera, Pierre [Henri Becquerel Cancer Center and Rouen University Hospital, Nuclear Medicine Department, Rouen (France); University of Rouen, QuantIF-LITIS (Equipe d' Accueil 4108-FR CNRS 3638), Faculty of Medicine, Rouen (France); Dubray, Bernard [University of Rouen, QuantIF-LITIS (Equipe d' Accueil 4108-FR CNRS 3638), Faculty of Medicine, Rouen (France); Centre Henri Becquerel and Rouen University Hospital, Department of Radiotherapy and Medical Physics, Rouen (France); Nkhali, Lamyaa; Thureau, Sebastien; Modzelewski, Romain; Gardin, Isabelle [Henri Becquerel Cancer Center and Rouen University Hospital, Nuclear Medicine Department, Rouen (France); University of Rouen, QuantIF-LITIS (Equipe d' Accueil 4108-FR CNRS 3638), Faculty of Medicine, Rouen (France); Centre Henri Becquerel and Rouen University Hospital, Department of Radiotherapy and Medical Physics, Rouen (France); Di Fiore, Frederic [Rouen University Hospital, Department of Gastroenterology, Rouen (France); Rouen University Hospital, Department of Oncology, Henri Becquerel Cancer Center, IRON, Rouen (France); Michel, Pierre [Rouen University Hospital, Department of Gastroenterology, Rouen (France)

    2015-05-01

    The high failure rates in the radiotherapy (RT) target volume suggest that patients with locally advanced oesophageal cancer (LAOC) would benefit from increased total RT doses. High 2-deoxy-2-[{sup 18}F]fluoro-D-glucose (FDG) uptake (hotspot) on pre-RT FDG positron emission tomography (PET)/CT has been reported to identify intra-tumour sites at increased risk of relapse after RT in non-small cell lung cancer and in rectal cancer. Our aim was to confirm these observations in patients with LAOC and to determine the optimal maximum standardized uptake value (SUV{sub max}) threshold to delineate smaller RT target volumes that would facilitate RT dose escalation without impaired tolerance. The study included 98 consecutive patients with LAOC treated by chemoradiotherapy (CRT). All patients underwent FDG PET/CT at initial staging and during systematic follow-up in a single institution. FDG PET/CT acquisitions were coregistered on the initial CT scan. Various subvolumes within the initial tumour (30, 40, 50, 60, 70, 80 and 90 % SUV{sub max} thresholds) and in the subsequent local recurrence (LR, 40 and 90 % SUV{sub max} thresholds) were pasted on the initial CT scan and compared[Dice, Jaccard, overlap fraction (OF), common volume/baseline volume, common volume/recurrent volume]. Thirty-five patients had LR. The initial metabolic tumour volume was significantly higher in LR tumours than in the locally controlled tumours (mean 25.4 vs 14.2 cc; p = 0.002). The subvolumes delineated on initial PET/CT with a 30-60 % SUV{sub max} threshold were in good agreement with the recurrent volume at 40 % SUV{sub max} (OF = 0.60-0.80). The subvolumes delineated on initial PET/CT with a 30-60 % SUV{sub max} threshold were in good to excellent agreement with the core volume (90 % SUV{sub max}) of the relapse (common volume/recurrent volume and OF indices 0.61-0.89). High FDG uptake on pretreatment PET/CT identifies tumour subvolumes that are at greater risk of recurrence after CRT in

  17. CT findings of perihepatic tuberculous abscess

    Energy Technology Data Exchange (ETDEWEB)

    Ryu, Jeong Ah; Lee, Jong Tae; Chung, Jae Joon; Park, Su Mi; Kim, Myeong Jin; Yoo, Hyung Sik [Yonsei Univ. College of Medicine, Research Institute of Radiological Science, Yonsei Univ., Seoul (Korea, Republic of)

    1999-12-01

    To evaluate the CT findings of perihepatic tuberculous abscesses. The CT scans of 11 patients (6 females and 5 males) with 14 pathologically proven perihepatic tuberculous abscess were retrospectively evaluated in terms of the morphological characteristics of the abscesses and changes in other abdominal organs and at other sites. A total of 14 absceses were noted in 11 patients. Six (43%) were in the right subphrenic space, three (21%) in the right perihepatic space, three (21%) in the left subphrenic space, and two (14%) in the left perihepatic space. The right side was predominant. The abscesses ranged in size from 1 to 10 (mean, 5) cm in diameter, with a wall thickness of 2-7 (mean, 3) mm. Of the 14 abscesses, 13 were oval, and one spherical. CT findings were as follows : a smooth abscess margin with even wall thickness in seven of the eleven patients (64%); calcification of the wall in two (18%); internal septa in seven (64%); localized fluid collection in nine (82%); lymphadenopathy in five (45%); and peritoneal enhancement in seven (64%). Lesions suggesting tuberculous infection coexisted at other sites in eight patients. These included the lung in six patients (55%), the neck in three (27%), an axilla in two (18%), the liver in two (18%), the spleen in one (9%), and the gastroin-testinal tract in one (9%). CT scanning is useful for establishing the diagnosis of perihepatic tuberculous abscesses by evaluating the morphological characteristics of the mass and by observing changes in other abdominal organs and at other sites.

  18. CT findings of perihepatic tuberculous abscess

    International Nuclear Information System (INIS)

    Ryu, Jeong Ah; Lee, Jong Tae; Chung, Jae Joon; Park, Su Mi; Kim, Myeong Jin; Yoo, Hyung Sik

    1999-01-01

    To evaluate the CT findings of perihepatic tuberculous abscesses. The CT scans of 11 patients (6 females and 5 males) with 14 pathologically proven perihepatic tuberculous abscess were retrospectively evaluated in terms of the morphological characteristics of the abscesses and changes in other abdominal organs and at other sites. A total of 14 absceses were noted in 11 patients. Six (43%) were in the right subphrenic space, three (21%) in the right perihepatic space, three (21%) in the left subphrenic space, and two (14%) in the left perihepatic space. The right side was predominant. The abscesses ranged in size from 1 to 10 (mean, 5) cm in diameter, with a wall thickness of 2-7 (mean, 3) mm. Of the 14 abscesses, 13 were oval, and one spherical. CT findings were as follows : a smooth abscess margin with even wall thickness in seven of the eleven patients (64%); calcification of the wall in two (18%); internal septa in seven (64%); localized fluid collection in nine (82%); lymphadenopathy in five (45%); and peritoneal enhancement in seven (64%). Lesions suggesting tuberculous infection coexisted at other sites in eight patients. These included the lung in six patients (55%), the neck in three (27%), an axilla in two (18%), the liver in two (18%), the spleen in one (9%), and the gastroin-testinal tract in one (9%). CT scanning is useful for establishing the diagnosis of perihepatic tuberculous abscesses by evaluating the morphological characteristics of the mass and by observing changes in other abdominal organs and at other sites

  19. Preliminary study on helical CT algorithms for patient motion estimation and compensation

    International Nuclear Information System (INIS)

    Wang, G.; Vannier, M.W.

    1995-01-01

    Helical computed tomography (helical/spiral CT) has replaced conventional CT in many clinical applications. In current helical CT, a patient is assumed to be rigid and motionless during scanning and planar projection sets are produced from raw data via longitudinal interpolation. However, rigid patient motion is a problem in some cases (such as in the skull base and temporal bone imaging). Motion artifacts thus generated in reconstructed images can prevent accurate diagnosis. Modeling a uniform translational movement, the authors address how patient motion is ascertained and how it may be compensated. First, mismatch between adjacent fan-beam projections of the same orientation is determined via classical correlation, which is approximately proportional to the patient displacement projected onto an axis orthogonal to the central ray of the involved fan-beam. Then, the patient motion vector (the patient displacement per gantry rotation) is estimated from its projections using a least-square-root method. To suppress motion artifacts, adaptive interpolation algorithms are developed that synthesize full-scan and half-scan planar projection data sets, respectively. In the adaptive scheme, the interpolation is performed along inclined paths dependent upon the patient motion vector. The simulation results show that the patient motion vector can be accurately and reliably estimated using their correlation and least-square-root algorithm, patient motion artifacts can be effectively suppressed via adaptive interpolation, and adaptive half-scan interpolation is advantageous compared with its full-scale counterpart in terms of high contrast image resolution

  20. Usefulness of low dose oral contrast media in FDG PET/CT

    Energy Technology Data Exchange (ETDEWEB)

    An, Y. S.; Yun, J. G.; Lee, M. H.; Cho, C. W.; Yun, S. N [Ajou University Medical Center, Suwon (Korea, Republic of)

    2004-07-01

    Oral contrast media might help in interpreting PET/CT images, allowing better discrimination between physiologic and pathologic abdominal uptake. The aim of this study was to evaluate the usefulness of low dose oral contrast on FDG PET/CT. A total of 435 cancer patients received 200mL of oral Barium with water(200mL) immediately before FDG injection. PET images were reconstructed using attenuation correction and iterative reconstruction. The FDG uptake in gastrointestinal(GI) tract were analyzed by visual and semiquantitative method in transaxial, coronal and sagittal planes. Seventy patients(16%, 113 sites) of 435 images showed high FDG uptake(pSUV>4.0) : 50(74%, 84 sites) with diffuse uptake and 20(26%, 29sites) with focal uptake. The most common distribution site of oral contrast media was small bowel (n=27, 39%) and others were small bowel with transverse colon(n=6, 8%), small bowel with ascending and sigmoid colon(n=6, 8%) and etc. In PET/CT images, FDG uptake coexisted with oral contrast was showed in 26 patients(54%) with diffuse pattern and 9(45%) with focal pattern, and by sites, those were 38(45%) and 9(31%), respectively. In small bowel regions, the most common distribution site, the proportion of coexistence reached as high as 61% (29 in the total 47 sites). Application of low dose contrast agent can be helpful in the evaluation of intestinal uptake in FDG PET/CT image.

  1. Usefulness of low dose oral contrast media in FDG PET/CT

    International Nuclear Information System (INIS)

    An, Y. S.; Yun, J. G.; Lee, M. H.; Cho, C. W.; Yun, S. N

    2004-01-01

    Oral contrast media might help in interpreting PET/CT images, allowing better discrimination between physiologic and pathologic abdominal uptake. The aim of this study was to evaluate the usefulness of low dose oral contrast on FDG PET/CT. A total of 435 cancer patients received 200mL of oral Barium with water(200mL) immediately before FDG injection. PET images were reconstructed using attenuation correction and iterative reconstruction. The FDG uptake in gastrointestinal(GI) tract were analyzed by visual and semiquantitative method in transaxial, coronal and sagittal planes. Seventy patients(16%, 113 sites) of 435 images showed high FDG uptake(pSUV>4.0) : 50(74%, 84 sites) with diffuse uptake and 20(26%, 29sites) with focal uptake. The most common distribution site of oral contrast media was small bowel (n=27, 39%) and others were small bowel with transverse colon(n=6, 8%), small bowel with ascending and sigmoid colon(n=6, 8%) and etc. In PET/CT images, FDG uptake coexisted with oral contrast was showed in 26 patients(54%) with diffuse pattern and 9(45%) with focal pattern, and by sites, those were 38(45%) and 9(31%), respectively. In small bowel regions, the most common distribution site, the proportion of coexistence reached as high as 61% (29 in the total 47 sites). Application of low dose contrast agent can be helpful in the evaluation of intestinal uptake in FDG PET/CT image

  2. SU-F-R-33: Can CT and CBCT Be Used Simultaneously for Radiomics Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Luo, R; Wang, J; Zhong, H; Gan, J; Hu, P; Shen, L; Hu, W; Zhang, Z [Fudan University Shanghai Cancer Center, Shanghai, Shanghai (China)

    2016-06-15

    Purpose: To investigate whether CBCT and CT can be used in radiomics analysis simultaneously. To establish a batch correction method for radiomics in two similar image modalities. Methods: Four sites including rectum, bladder, femoral head and lung were considered as region of interest (ROI) in this study. For each site, 10 treatment planning CT images were collected. And 10 CBCT images which came from same site of same patient were acquired at first radiotherapy fraction. 253 radiomics features, which were selected by our test-retest study at rectum cancer CT (ICC>0.8), were calculated for both CBCT and CT images in MATLAB. Simple scaling (z-score) and nonlinear correction methods were applied to the CBCT radiomics features. The Pearson Correlation Coefficient was calculated to analyze the correlation between radiomics features of CT and CBCT images before and after correction. Cluster analysis of mixed data (for each site, 5 CT and 5 CBCT data are randomly selected) was implemented to validate the feasibility to merge radiomics data from CBCT and CT. The consistency of clustering result and site grouping was verified by a chi-square test for different datasets respectively. Results: For simple scaling, 234 of the 253 features have correlation coefficient ρ>0.8 among which 154 features haveρ>0.9 . For radiomics data after nonlinear correction, 240 of the 253 features have ρ>0.8 among which 220 features have ρ>0.9. Cluster analysis of mixed data shows that data of four sites was almost precisely separated for simple scaling(p=1.29 * 10{sup −7}, χ{sup 2} test) and nonlinear correction (p=5.98 * 10{sup −7}, χ{sup 2} test), which is similar to the cluster result of CT data (p=4.52 * 10{sup −8}, χ{sup 2} test). Conclusion: Radiomics data from CBCT can be merged with those from CT by simple scaling or nonlinear correction for radiomics analysis.

  3. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Children's (Pediatric) CT (Computed ...

  4. CT diagnosis of blunt laryngeal trauma

    International Nuclear Information System (INIS)

    Kong Fanbin; Xia Ruigan; Hu Libin

    2000-01-01

    Objective: To analyze CT findings of blunt laryngeal trauma (BLT) and evaluate the value of CT in the diagnosis of BLT. Methods: CT diagnosis and treatment of 16 patients with BLT were reviewed. Results: Soft-tissue injuries were detected in five cases including swelling of the aryepiglottic folds, the false or true vocal cords and airway narrowing in four, and left cricoarytenoid dislocation and card paralysis in one. Supraglottic injuries in two cases including c fractures of the epiglottis in 2 and associated with a laceration of the aryepiglottic folds and the hypopharynx. Glottic injuries in four cases including ventricle fracture of the right thyroid ala in one and midline ventricle or comminute fractures of the thyroid cartilage in three, a square segment of cartilage was depressed into the larynx, and the true vocal cords and the anterior commissure were disrupted in one of this series. Subglottic injuries in five cases including cricoid ring fracture on the opposite side following a lateral force in one, with the fragment depressed into the larynx. Two showed marked comminution of the cricoid ring. Midline vertical fracture of the posterior cricoid plate associated with the laceration of the first tracheal ring in one, and one presented marked disruption of the right cricothyroid joint. Conclusion: CT clearly shows the extent of cartilaginous injury and displacement, related soft-tissue changes and the degree of resulting airway encroachment, and it may be successfully used to determine the need for open exploration and repair in selected cases of blunt trauma to the larynx

  5. Earthquake-induced crustal deformation and consequences for fault displacement hazard analysis of nuclear power plants

    International Nuclear Information System (INIS)

    Gürpinar, Aybars; Serva, Leonello; Livio, Franz; Rizzo, Paul C.

    2017-01-01

    Highlights: • A three-step procedure to incorporate coseismic deformation into PFDHA. • Increased scrutiny for faults in the area permanently deformed by future strong earthquakes. • These faults share with the primary structure the same time window for fault capability. • VGM variation may occur due to tectonism that has caused co-seismic deformation. - Abstract: Readily available interferometric data (InSAR) of the coseismic deformation field caused by recent seismic events clearly show that major earthquakes produce crustal deformation over wide areas, possibly resulting in significant stress loading/unloading of the crust. Such stress must be considered in the evaluation of seismic hazards of nuclear power plants (NPP) and, in particular, for the potential of surface slip (i.e., probabilistic fault displacement hazard analysis - PFDHA) on both primary and distributed faults. In this study, based on the assumption that slip on pre-existing structures can represent the elastic response of compliant fault zones to the permanent co-seismic stress changes induced by other major seismogenic structures, we propose a three-step procedure to address fault displacement issues and consider possible influence of surface faulting/deformation on vibratory ground motion (VGM). This approach includes: (a) data on the presence and characteristics of capable faults, (b) data on recognized and/or modeled co-seismic deformation fields and, where possible, (c) static stress transfer between source and receiving faults of unknown capability. The initial step involves the recognition of the major seismogenic structures nearest to the site and their characterization in terms of maximum expected earthquake and the time frame to be considered for determining their “capability” (as defined in the International Atomic Energy Agency - IAEA Specific Safety Guide SSG-9). Then a GIS-based buffer approach is applied to identify all the faults near the NPP, possibly influenced by

  6. Earthquake-induced crustal deformation and consequences for fault displacement hazard analysis of nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Gürpinar, Aybars, E-mail: aybarsgurpinar2007@yahoo.com [Nuclear & Risk Consultancy, Anisgasse 4, 1221 Vienna (Austria); Serva, Leonello, E-mail: lserva@alice.it [Independent Consultant, Via dei Dauni 1, 00185 Rome (Italy); Livio, Franz, E-mail: franz.livio@uninsubria.it [Dipartimento di Scienza ed Alta Tecnologia, Università degli Studi dell’Insubria, Via Velleggio, 11, 22100 Como (Italy); Rizzo, Paul C., E-mail: paul.rizzo@rizzoasoc.com [RIZZO Associates, 500 Penn Center Blvd., Suite 100, Pittsburgh, PA 15235 (United States)

    2017-01-15

    Highlights: • A three-step procedure to incorporate coseismic deformation into PFDHA. • Increased scrutiny for faults in the area permanently deformed by future strong earthquakes. • These faults share with the primary structure the same time window for fault capability. • VGM variation may occur due to tectonism that has caused co-seismic deformation. - Abstract: Readily available interferometric data (InSAR) of the coseismic deformation field caused by recent seismic events clearly show that major earthquakes produce crustal deformation over wide areas, possibly resulting in significant stress loading/unloading of the crust. Such stress must be considered in the evaluation of seismic hazards of nuclear power plants (NPP) and, in particular, for the potential of surface slip (i.e., probabilistic fault displacement hazard analysis - PFDHA) on both primary and distributed faults. In this study, based on the assumption that slip on pre-existing structures can represent the elastic response of compliant fault zones to the permanent co-seismic stress changes induced by other major seismogenic structures, we propose a three-step procedure to address fault displacement issues and consider possible influence of surface faulting/deformation on vibratory ground motion (VGM). This approach includes: (a) data on the presence and characteristics of capable faults, (b) data on recognized and/or modeled co-seismic deformation fields and, where possible, (c) static stress transfer between source and receiving faults of unknown capability. The initial step involves the recognition of the major seismogenic structures nearest to the site and their characterization in terms of maximum expected earthquake and the time frame to be considered for determining their “capability” (as defined in the International Atomic Energy Agency - IAEA Specific Safety Guide SSG-9). Then a GIS-based buffer approach is applied to identify all the faults near the NPP, possibly influenced by

  7. Validity and feasibility of a satellite imagery-based method for rapid estimation of displaced populations.

    Science.gov (United States)

    Checchi, Francesco; Stewart, Barclay T; Palmer, Jennifer J; Grundy, Chris

    2013-01-23

    Estimating the size of forcibly displaced populations is key to documenting their plight and allocating sufficient resources to their assistance, but is often not done, particularly during the acute phase of displacement, due to methodological challenges and inaccessibility. In this study, we explored the potential use of very high resolution satellite imagery to remotely estimate forcibly displaced populations. Our method consisted of multiplying (i) manual counts of assumed residential structures on a satellite image and (ii) estimates of the mean number of people per structure (structure occupancy) obtained from publicly available reports. We computed population estimates for 11 sites in Bangladesh, Chad, Democratic Republic of Congo, Ethiopia, Haiti, Kenya and Mozambique (six refugee camps, three internally displaced persons' camps and two urban neighbourhoods with a mixture of residents and displaced) ranging in population from 1,969 to 90,547, and compared these to "gold standard" reference population figures from census or other robust methods. Structure counts by independent analysts were reasonably consistent. Between one and 11 occupancy reports were available per site and most of these reported people per household rather than per structure. The imagery-based method had a precision relative to reference population figures of layout. For each site, estimates were produced in 2-5 working person-days. In settings with clearly distinguishable individual structures, the remote, imagery-based method had reasonable accuracy for the purposes of rapid estimation, was simple and quick to implement, and would likely perform better in more current application. However, it may have insurmountable limitations in settings featuring connected buildings or shelters, a complex pattern of roofs and multi-level buildings. Based on these results, we discuss possible ways forward for the method's development.

  8. Internal Displacement: Livelihood saving responses

    OpenAIRE

    Deborah Hines

    2001-01-01

    Deborah Hines explores how to assist the internally displaced and those prone to displacement. She considers the major causes of internal displacement, making the case for a more comprehensive set of policy and operational actions in response to situations of internal displacement. Development (2001) 44, 34–39. doi:10.1057/palgrave.development.1110289

  9. Impact of institutional volume and experience with CT interpretation on sizing of transcatheter aortic valves: A multicenter retrospective study

    International Nuclear Information System (INIS)

    Verma, Divya Ratan; Pershad, Yash; Pershad, Ashish; Fang, Kenith; Gellert, George; Morris, Michael F.

    2016-01-01

    Background: Computed tomography (CT) has become the standard imaging modality for pre-procedural aortic annular sizing prior to transcatheter aortic valve replacement (TAVR). We hypothesized that the accuracy of CT derived annular measurements would be greater at sites with higher TAVR procedural volume. Methods: Within a large integrated health system, TAVR was performed at low ( 75 cases). 181 patients underwent TAVR with a Sapien XT transcatheter heart valve (THV). Two blinded experienced readers independently remeasured the annulus on CT and compared their measurements to site reported measurements. Hypothetical THV sizes were chosen based on measurements from site CT reports and independent readers’ measurements, and compared to the implanted THV size. Results: Correlation between site reported measurements and independent readers measurements of mean annulus size varied between low-volume (r = 0.31, p = 0.18), intermediate-volume (r = 0.34, p = 0.01), and high-volume sites (r = 0.96, p < 0.01). On multivariate analysis, interpretation of ≥20 CT scans (OR 0.29; 95% CI 0.03–0.81; p 0.02) and high-volume site (OR 0.16; 95% CI 0.10–0.82; p 0.02) were associated with reduced mismatch between the site predicted THV size and independent readers predicted THV size. Mismatch between site predicted THV size and implanted THV size was associated with a worse 30-day composite of mortality, dialysis-dependent renal failure, cerebrovascular accident, new permanent pacemaker, and hospital readmission (55.3 vs. 38.7%; p = 0.05). Conclusions: Accuracy of CT aortic annular sizing is improved with higher individual experience and site TAVR volume. These findings should be confirmed in larger, prospective studies. - Highlights: • Accuracy of CT aortic annular sizing is improved with higher individual experience and site TAVR volume. • CT readers with experience interpreting ≥20 pre-TAVR CT scans had significantly improved accuracy in identifying the annulus.

  10. Mesenchymal chondrosarcoma of the orbit: CT and MRI findings

    Energy Technology Data Exchange (ETDEWEB)

    Yang, B.T., E-mail: cjr.yangbentao@vip.163.com [Department of Radiology, Beijing Tongren Hospital, Capital Medical University, Beijing (China); Wang, Y.Z.; Wang, X.Y.; Wang, Z.C. [Department of Radiology, Beijing Tongren Hospital, Capital Medical University, Beijing (China)

    2012-04-15

    Aim: To describe the computed tomography (CT) and magnetic resonance imaging (MRI) features of orbital mesenchymal chondrosarcomas (MCSs). Materials and methods: Six patients with histology-confirmed MCSs of the orbit were retrospectively reviewed. All six patients underwent CT and MRI. Imaging studies were evaluated for the following: (a) tumour location, (b) configuration, size, and margin, (c) CT attenuation and MRI signal intensity, and (d) secondary manifestations. Additionally, the time-intensity curve (TIC) of dynamic contrast-enhanced (DCE) MRI were analysed in five patients. Results: Two MCSs arose in the right orbit and four in the left orbit. Five MCSs were located in the retrobulbar intraconal space and one in the extraconal space. All the lesions displayed a lobulate configuration and had a well-defined margin. The mean maximum diameter was 25.8 mm (range 15-36 mm). On unenhanced CT, the lesions appeared isodense to grey matter in six patients, with calcifications in five. Two patients showed inhomogeneous, moderate enhancement on enhanced CT. Six MCSs appeared isointense on T1-weighted imaging and heterogeneously isointense on T2-weighted imaging. The lesions showed significantly heterogeneous contrast enhancement. Five patients had DCE MRI and the TICs showed a rapidly enhancing and rapid washout pattern (type III). The following features were also detected: compression of the extra-ocular muscle (six patients, 100%); displacement of the optic nerve (five patients, 83.3%); and encasing globe (three patients, 50%). Conclusions: A well-defined, lobulate orbital mass with calcification on CT and, marked heterogeneous enhancement and type III TIC on MRI are highly suspicious of orbital MCSs.

  11. WE-AB-BRA-04: Evaluation of the Tumor Registration Error in Biopsy Procedures Performed Under Real Time PET/CT Guidance

    International Nuclear Information System (INIS)

    Fanchon, L; Apte, A; Dzyubak, O; Mageras, G; Yorke, E; Solomon, S; Kirov, A; Visvikis, D; Hatt, M

    2015-01-01

    Purpose: PET/CT guidance is used for biopsies of metabolically active lesions, which are not well seen on CT alone or to target the metabolically active tissue in tumor ablations. It has also been shown that PET/CT guided biopsies provide an opportunity to verify the location of the lesion border at the place of needle insertion. However the error in needle placement with respect to the metabolically active region may be affected by motion between the PET/CT scan performed at the start of the procedure and the CT scan performed with the needle in place and this error has not been previously quantified. Methods: Specimens from 31 PET/CT guided biopsies were investigated and correlated to the intraoperative PET scan under an IRB approved HIPAA compliant protocol. For 4 of the cases in which larger motion was suspected a second PET scan was obtained with the needle in place. The CT and the PET images obtained before and after the needle insertion were used to calculate the displacement of the voxels along the needle path. CTpost was registered to CTpre using a free form deformable registration and then fused with PETpre. The shifts between the PET image contours (42% of SUVmax) for PETpre and PETpost were obtained at the needle position. Results: For these extreme cases the displacement of the CT voxels along the needle path ranged from 2.9 to 8 mm with a mean of 5 mm. The shift of the PET image segmentation contours (42% of SUVmax) at the needle position ranged from 2.3 to 7 mm between the two scans. Conclusion: Evaluation of the mis-registration between the CT with the needle in place and the pre-biopsy PET can be obtained using deformable registration of the respective CT scans and can be used to indicate the need of a second PET in real-time. This work is supported in part by a grant from Biospace Lab, S.A

  12. Approaching population thresholds in presence of uncertainty: Assessing displacement of seabirds from offshore wind farms

    International Nuclear Information System (INIS)

    Busch, Malte; Garthe, Stefan

    2016-01-01

    Assessment of the displacement impacts of offshore wind farms on seabirds is impeded by a lack of evidence regarding species-specific reactions to developed sites and the potential ecological consequences faced by displaced individuals. In this study, we present a method that makes best use of the currently limited understanding of displacement impacts. The combination of a matrix table displaying the full range of potential displacement and mortality levels together with seasonal potential biological removal (PBR) assessments provides a tool that increases confidence in the conclusions of impact assessments. If unrealistic displacement levels and/or mortality rates are required to equal or approach seasonal PBRs, this gives an indication of the likeliness of adverse impacts on the assessed population. This approach is demonstrated by assessing the displacement impacts of an offshore wind farm cluster in the German North Sea on the local common guillemot (Uria aalge) population. - Highlights: • A novel approach for assessing displacement impacts of offshore wind farms on seabirds is presented making best use of limited data • A displacement matrix approach is linked with PBR analysis to increased confidence in assessment conclusions drawn • A case example demonstrates the applicability of the methods described in practice

  13. Approaching population thresholds in presence of uncertainty: Assessing displacement of seabirds from offshore wind farms

    Energy Technology Data Exchange (ETDEWEB)

    Busch, Malte, E-mail: der.malte.busch@gmail.com; Garthe, Stefan

    2016-01-15

    Assessment of the displacement impacts of offshore wind farms on seabirds is impeded by a lack of evidence regarding species-specific reactions to developed sites and the potential ecological consequences faced by displaced individuals. In this study, we present a method that makes best use of the currently limited understanding of displacement impacts. The combination of a matrix table displaying the full range of potential displacement and mortality levels together with seasonal potential biological removal (PBR) assessments provides a tool that increases confidence in the conclusions of impact assessments. If unrealistic displacement levels and/or mortality rates are required to equal or approach seasonal PBRs, this gives an indication of the likeliness of adverse impacts on the assessed population. This approach is demonstrated by assessing the displacement impacts of an offshore wind farm cluster in the German North Sea on the local common guillemot (Uria aalge) population. - Highlights: • A novel approach for assessing displacement impacts of offshore wind farms on seabirds is presented making best use of limited data • A displacement matrix approach is linked with PBR analysis to increased confidence in assessment conclusions drawn • A case example demonstrates the applicability of the methods described in practice.

  14. Clinical investigation of flat panel CT following middle ear reconstruction: a study of 107 patients

    Energy Technology Data Exchange (ETDEWEB)

    Zaoui, K. [University Hospital Heidelberg, Ruprecht Karls University, Department of Otorhinolaryngology, Head and Neck Surgery, Heidelberg (Germany); Kromeier, J. [St. Josefs Hospital, RkK, Department of Radiology, Freiburg (Germany); Neudert, M.; Beleites, T.; Zahnert, T. [University Hospital Dresden, Technical University, Department of Otorhinolaryngology, Head and Neck Surgery, Dresden (Germany); Laszig, R.; Offergeld, C. [University Hospital Freiburg, Albert Ludwigs University, Department of Otorhinolaryngology, Head and Neck Surgery, Freiburg (Germany)

    2014-03-15

    After middle ear reconstruction using partial or total ossicular replacement prostheses (PORP/TORP), an air-bone gap (ABG) may persist because of prosthesis displacement or malposition. So far, CT of the temporal bone has played the main role in the diagnosis of reasons for postoperative insufficient ABG improvement. Recent experimental and clinical studies have evaluated flat panel CT (fpCT) as an alternative imaging technique that provides images with high isovolumetric resolution, fewer metal-induced artefacts and lower irradiation doses. One hundred and seven consecutive patients with chronic otitis media with or without cholesteatoma underwent reconstruction by PORP (n = 52) or TORP (n = 55). All subjects underwent preoperative and postoperative audiometric testing and postoperative fpCT. Statistical evaluation of all 107 patients as well as the sole sub-assembly groups (PORP or TORP) showed a highly significant correlation between hearing improvement and fpCT-determined prosthesis position. FpCT enables detailed postoperative information on patients with middle ear reconstruction. FpCT is a new imaging technique that provides immediate feedback on surgical results after reconstructive middle ear surgery. Specific parameters evaluated by fpCT may serve as a predictive tool for estimated postoperative hearing improvement. Therefore this imaging technique is suitable for postoperative quality control in reconstructive middle ear surgery. (orig.)

  15. Rate of displacement for Jakob Type 1 lateral condyle fractures treated with a cast.

    Science.gov (United States)

    Zale, C; Winthrop, Z A; Hennrikus, W

    2018-04-01

    The aim of this retrospective study is to report the rate of displacement of Jakob Type 1 lateral condyle fractures that were initially treated in a cast. We performed a retrospective review of all patients that were treated for a non-displaced (Jakob Type 1 displaced and were converted to a closed pinning treatment plan with a conversion rate of 8.5%. There was a mean of 13.2 days (4 to 21) between treatment by initial casting and closed pinning. This study demonstrates an 8.5% displacement and conversion rate from cast treatment to closed pinning for initially non-displaced Jakob Type 1 lateral condyle fractures of the humerus. The internal oblique radiograph is most accurate to determine displacement. We recommend obtaining an internal oblique view at initial evaluation and at follow-up in the cast for lateral condyle fractures. To minimize movement at the fracture site, we recommend treating Jakob Type 1 lateral condyle fractures with a long arm cast with the elbow at 90° and the forearm in the supine position with a sling-loop design. IV - retrospective therapeutic study.

  16. Charge-transfer energy in the water-hydrogen molecular aggregate revealed by molecular-beam scattering experiments, charge displacement analysis, and ab initio calculations.

    Science.gov (United States)

    Belpassi, Leonardo; Reca, Michael L; Tarantelli, Francesco; Roncaratti, Luiz F; Pirani, Fernando; Cappelletti, David; Faure, Alexandre; Scribano, Yohann

    2010-09-22

    Integral cross-section measurements for the system water-H(2) in molecular-beam scattering experiments are reported. Their analysis demonstrates that the average attractive component of the water-H(2) intermolecular potential in the well region is about 30% stronger than dispersion and induction forces would imply. An extensive and detailed theoretical analysis of the electron charge displacement accompanying the interaction, over several crucial sections of the potential energy surface (PES), shows that water-H(2) interaction is accompanied by charge transfer (CT) and that the observed stabilization energy correlates quantitatively with CT magnitude at all distances. Based on the experimentally determined potential and the calculated CT, a general theoretical model is devised which reproduces very accurately PES sections obtained at the CCSD(T) level with large basis sets. The energy stabilization associated with CT is calculated to be 2.5 eV per electron transferred. Thus, CT is shown to be a significant, strongly stereospecific component of the interaction, with water functioning as electron donor or acceptor in different orientations. The general relevance of these findings for water's chemistry is discussed.

  17. Impact of institutional volume and experience with CT interpretation on sizing of transcatheter aortic valves: A multicenter retrospective study

    Energy Technology Data Exchange (ETDEWEB)

    Verma, Divya Ratan [Cardiovascular Institute, Banner University Medical Center, Phoenix, AZ (United States); Division of Interventional Cardiology, Banner University Medical Center, Phoenix, AZ (United States); Pershad, Yash [Department of Radiology, Banner University Medical Center, Phoenix, AZ (United States); Pershad, Ashish [Cardiovascular Institute, Banner University Medical Center, Phoenix, AZ (United States); Division of Interventional Cardiology, Banner University Medical Center, Phoenix, AZ (United States); Fang, Kenith [Cardiovascular Institute, Banner University Medical Center, Phoenix, AZ (United States); Division of Cardiothoracic Surgery, Banner University Medical Center, Phoenix, AZ (United States); Gellert, George [Cardiovascular Institute, Banner University Medical Center, Phoenix, AZ (United States); Department of Anesthesiology, Banner University Medical Center, Phoenix, AZ (United States); Morris, Michael F., E-mail: mfmorris@mail.arizona.edu [Cardiovascular Institute, Banner University Medical Center, Phoenix, AZ (United States); Department of Radiology, Banner University Medical Center, Phoenix, AZ (United States)

    2016-12-15

    Background: Computed tomography (CT) has become the standard imaging modality for pre-procedural aortic annular sizing prior to transcatheter aortic valve replacement (TAVR). We hypothesized that the accuracy of CT derived annular measurements would be greater at sites with higher TAVR procedural volume. Methods: Within a large integrated health system, TAVR was performed at low (<40 cases), intermediate (40–75 cases), and high-volume sites (>75 cases). 181 patients underwent TAVR with a Sapien XT transcatheter heart valve (THV). Two blinded experienced readers independently remeasured the annulus on CT and compared their measurements to site reported measurements. Hypothetical THV sizes were chosen based on measurements from site CT reports and independent readers’ measurements, and compared to the implanted THV size. Results: Correlation between site reported measurements and independent readers measurements of mean annulus size varied between low-volume (r = 0.31, p = 0.18), intermediate-volume (r = 0.34, p = 0.01), and high-volume sites (r = 0.96, p < 0.01). On multivariate analysis, interpretation of ≥20 CT scans (OR 0.29; 95% CI 0.03–0.81; p 0.02) and high-volume site (OR 0.16; 95% CI 0.10–0.82; p 0.02) were associated with reduced mismatch between the site predicted THV size and independent readers predicted THV size. Mismatch between site predicted THV size and implanted THV size was associated with a worse 30-day composite of mortality, dialysis-dependent renal failure, cerebrovascular accident, new permanent pacemaker, and hospital readmission (55.3 vs. 38.7%; p = 0.05). Conclusions: Accuracy of CT aortic annular sizing is improved with higher individual experience and site TAVR volume. These findings should be confirmed in larger, prospective studies. - Highlights: • Accuracy of CT aortic annular sizing is improved with higher individual experience and site TAVR volume. • CT readers with experience interpreting ≥20 pre-TAVR CT scans had

  18. Differential diagnosis between chronic otitis media with and without cholesteatoma by temporal bone CT: focus on bone change and mass effect

    International Nuclear Information System (INIS)

    Jung, Cheol Kyu; Park, Dong Woo; Seong, Jin Yong; Lee, Kak Soo; Park Choong Ki; Lee, Seung Ro; Hahm, Chang Kok

    2000-01-01

    In order to determine specific differences, we compared the temporal bone CT findings of chronic otitis media (COM) with and without cholesteatoma, focusing on bone change. Between 1997 and 1998, 82 patients (84 cases) underwent temporal bone CT and were shown to have COM, with or without cholesteatoma after mastoidectomy and tympanoplasty. There were 36 cases of COM with cholesteatoma (26 patients, M:F =3D 11:15; age range, 16-61 (mean, 36,2) years), and 58 cases without chlesteatoma (56 patients, M:F =3D 25:31, age range, 15-61 (mean, 36.2) years). The findings of temporal bone CT were analysed at the point of bony changes including erosion and medial displacement of ossicles (malleus, incus, and stapes), erosion or destruction of the scutum, tegmen, facial canal, and lateral semicircular canal, and ballooning of the tympanic cavity and mastoid antrum. In addition, the soft tissue changes seen on temporal bone CT were analyzed at the site of lateral bulging of soft tissue in Prussak's space, perforation of the pars flaccida, tympanic membrane retraction, and tympanosclerosis. We retrospectively compared the findings of temporal bone CT with the surgical findings, and to assess statistical significance, the Chi-square test was used. Bone erosion or destruction was seen in 36.2% of COM cases without cholesteatoma, and in 96.2% of cases with cholesteatoma. Comparing COM with and without cholesteatoma, the erosion of ossicles including the malleus (81%, 24%), incus (88%, 14%), stapes (58%, 10%), scutum (88%, 10%), facial canal (8%, 0%), and lateral semicircular canal (8%, 0%), was more common in COM with cholesteatoma (p-value less than 0.05), with the exception of erosion of the tegmen (8%, 3%). Other bony changes including medial displacement of ossicles (27%, 3%), ballooning of tympanic cavity and mastoid antrum (96%, 16%), and the soft tissue changes including lateral bulging of soft tissue in Prussak's space (58%, 14%) and perforation of the pars flaccida (35

  19. Differential diagnosis between chronic otitis media with and without cholesteatoma by temporal bone CT: focus on bone change and mass effect

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Cheol Kyu; Park, Dong Woo; Seong, Jin Yong; Lee, Kak Soo; Park Choong Ki; Lee, Seung Ro; Hahm, Chang Kok [College of Medicine, Hanyang University, Seoul (Korea, Republic of)

    2000-01-01

    In order to determine specific differences, we compared the temporal bone CT findings of chronic otitis media (COM) with and without cholesteatoma, focusing on bone change. Between 1997 and 1998, 82 patients (84 cases) underwent temporal bone CT and were shown to have COM, with or without cholesteatoma after mastoidectomy and tympanoplasty. There were 36 cases of COM with cholesteatoma (26 patients, M:F =3D 11:15; age range, 16-61 (mean, 36,2) years), and 58 cases without chlesteatoma (56 patients, M:F =3D 25:31, age range, 15-61 (mean, 36.2) years). The findings of temporal bone CT were analysed at the point of bony changes including erosion and medial displacement of ossicles (malleus, incus, and stapes), erosion or destruction of the scutum, tegmen, facial canal, and lateral semicircular canal, and ballooning of the tympanic cavity and mastoid antrum. In addition, the soft tissue changes seen on temporal bone CT were analyzed at the site of lateral bulging of soft tissue in Prussak's space, perforation of the pars flaccida, tympanic membrane retraction, and tympanosclerosis. We retrospectively compared the findings of temporal bone CT with the surgical findings, and to assess statistical significance, the Chi-square test was used. Bone erosion or destruction was seen in 36.2% of COM cases without cholesteatoma, and in 96.2% of cases with cholesteatoma. Comparing COM with and without cholesteatoma, the erosion of ossicles including the malleus (81%, 24%), incus (88%, 14%), stapes (58%, 10%), scutum (88%, 10%), facial canal (8%, 0%), and lateral semicircular canal (8%, 0%), was more common in COM with cholesteatoma (p-value less than 0.05), with the exception of erosion of the tegmen (8%, 3%). Other bony changes including medial displacement of ossicles (27%, 3%), ballooning of tympanic cavity and mastoid antrum (96%, 16%), and the soft tissue changes including lateral bulging of soft tissue in Prussak's space (58%, 14%) and perforation of the pars

  20. Shape and dimensions of cardiac chambers: Importance of CT section thickness and orientation

    International Nuclear Information System (INIS)

    Hoffman, E.A.; Ritman, E.L.

    1985-01-01

    Three-dimensional (3D) computed tomography (CT) scan data were used to quantitate the geometry of all heart chambers. The Dynamic Spatial Reconstructor (DSR) was used to scan dogs with in situ casts of the cardiac chambers. Chamber volumes estimated from DSR images were accurate within 5% of water displacement volume measurements of the actual casts for chambers greater than 11 ml and within 10% of water displacement volumes for chambers less than 11 ml. Anatomic features of the actual cast correlated closely with anatomy visible in computer-generated surface images of the 3D DSR image data. The important effect of reconstructed section thickness and orientation on the fidelity of 3D cardiac geometry is demonstrated

  1. Strategies for displacing oil

    Science.gov (United States)

    Rao, Vikram; Gupta, Raghubir

    2015-03-01

    Oil currently holds a monopoly on transportation fuels. Until recently biofuels were seen as the means to break this stranglehold. They will still have a part to play, but the lead role has been handed to natural gas, almost solely due to the increased availability of shale gas. The spread between oil and gas prices, unprecedented in its scale and duration, will cause a secular shift away from oil as a raw material. In the transport fuel sector, natural gas will gain traction first in the displacement of diesel fuel. Substantial innovation is occurring in the methods of producing liquid fuel from shale gas at the well site, in particular in the development of small scale distributed processes. In some cases, the financing of such small-scale plants may require new business models.

  2. CT scan of pituitary adenomas

    International Nuclear Information System (INIS)

    Sakoda, K.; Mukada, K.; Yonezawa, M.; Matsumura, S.; Yoshimoto, H.; Mori, S.; Uozumi, T.

    1981-01-01

    CT scan is an extremely useful, almost harmless means of diagnosing pituitary adenomas. Growth hormone (GH)-secreting adenomas tend to have higher absorption coefficent in plain CT than the nonfunctioning and prolactin (PRL)-secreting adenomas. The absorption coefficent on contrast-enhanced CT does not identify the specific type of adenoma. Ring-like enhancement was observed in five nonfunctioning and four PRL-secreting adenomas with suprasellar extension, while cystic components were observed in four nonfunctioning and four PRL-secreting adenomas. In three of ten cases of PRL-secreting microadenomas, the site corresponding to the adenoma was not enhanced, whereas the normal pituitary was. A correlation exists between the size of PRL-secreting adenoma and the serum PRL level, but not between the size of GH-secreting adenomas and the serum GH level. (orig.)

  3. On-site bridge inspection with partial CT by 3.95Mev X-band linac source

    International Nuclear Information System (INIS)

    Wu, Wenjing; Zhu, Haito; Jin, Ming

    2012-01-01

    Since more and more bridges built several decades ago in Japan have become aged and dangerous, the non-destructive evaluation of those bridges is really an urgent problem. CT system with portable 3.95MeV linacs for bridge inspection is considered to work on-site, considering the law of Japanese radiation protection allows using linacs up to 4MeV outside radiation controlled area. The system would confirm the internal steel situation of bridges and analyze structural strain and stress with 3D model built from sectional imaging to evaluate load-bearing performance. The reconstruction process of bridge imaging is based on partial scanned data because bridge shape confines possible scanning angle to smaller than 180deg and a few translations. A small concrete sample with internal steel bars and attachment accessories is scanned in laboratory as preliminary work. (author)

  4. Direct observation of the lattice sites of implanted manganese in silicon

    CERN Document Server

    Silva, Daniel; Wahl, Ulrich; Martins Correia, Joao; Amorim, Lígia; Decoster, Stefan; Castro Ribeiro Da Silva, Manuel; Da Costa Pereira, Lino Miguel; Esteves De Araujo, Araujo Joao Pedro

    2016-01-01

    Mn-doped Si has attracted significant interest in the context of dilute magnetic semiconductors. We investigated the lattice location of implanted Mn in silicon of different doping types (n, n+ and p+) in the highly dilute regime. Three different lattice sites were identified by means of emission channeling experiments: ideal substitutional sites; sites displaced from bond-centered towards substitutional sites and sites displaced from anti-bonding towards tetrahedral interstitial sites. For all doping types investigated, the substitutional fraction remained below ∼ 30%. We discuss the origin of the observed lattice sites as well as the implications of such structures on the understanding of Mn-doped Si systems.

  5. Field demonstration of an active reservoir pressure management through fluid injection and displaced fluid extractions at the Rock Springs Uplift, a priority geologic CO2 storage site for Wyoming

    Energy Technology Data Exchange (ETDEWEB)

    Jiao, Zunsheng [Univ. of Wyoming, Laramie, WY (United States)

    2017-04-05

    This report provides the results from the project entitled Field Demonstration of Reservoir Pressure Management through Fluid Injection and Displaced Fluid Extraction at the Rock Springs Uplift, a Priority Geologic CO2 Storage Site for Wyoming (DE-FE0026159 for both original performance period (September 1, 2015 to August 31, 2016) and no-cost extension (September 1, 2016 to January 6, 2017)).

  6. SCT-4800T whole body X-ray CT scanner

    International Nuclear Information System (INIS)

    Okumura, Yoshitaka; Sato, Yukio; Kuwahara, Hiroshi

    1994-01-01

    A whole body X-ray CT scanner, the SCT-4800T (trade name: INTELLECT series), has been developed. This system is the first CT scanner that is combined with general radiographic functions. The general radiographic functions include a patient couch with film casette and several tube support systems along with the CT scanner. This newly designed CT scanner also features a compact and light-weight gantry with a 700 mm diameter apperture and user-friendly operater's console. The SCT-4800T brings a new level of patient and operator comfort to the emergency radiology examination site. (author)

  7. Stress and displacement patterns in the craniofacial skeleton with rapid maxillary expansion—a finite element method study

    Directory of Open Access Journals (Sweden)

    J. Priyadarshini

    2017-07-01

    Full Text Available Abstract Background Rapid maxillary expansion (RME, indicated in the treatment of maxillary deficiency directs high forces to maxillary basal bone and to other adjacent skeletal bones. The aim of this study is to (i evaluate stress distribution along craniofacial sutures and (ii study the displacement of various craniofacial structures with rapid maxillary expansion therapy by using a Finite Element model. Methods An analytical model was developed from a dried human skull of a 12 year old male. CT scan images of the skull were taken in axial direction parallel to the F-H plane at 1 mm interval, processed using Mimics software, required portion of the skull was exported into stereo-lithography model. ANSYS software was used to solve the mathematical equation. Contour plots of the displacement and stresses were obtained from the results of the analysis performed. Results At Node 47005, maximum X-displacement was 5.073 mm corresponding to the incisal edge of the upper central incisor. At Node 3971, maximum negative Y-displacement was -0.86 mm which corresponds to the anterior zygomatic arch, indicating posterior movement of craniofacial complex. At Node 32324, maximum negative Z-displacement was -0.92 mm representing the anterior and deepest convex portion of the nasal septum; indicating downward displacement of structures medial to the area of force application. Conclusions Pyramidal displacement of maxilla was evident. Apex of pyramid faced the nasal bone and base was located on the oral side. Posterosuperior part of nasal cavity moved minimally in lateral direction and width of nasal cavity at the floor of the nose increased, there was downward and forward movement of maxilla with a tendency toward posterior rotation. Maximum von Mises stresses were found along midpalatal, pterygomaxillary, nasomaxillary and frontomaxillary sutures.

  8. Utility of CT scan for the diagnosis of chest wall tuberculosis

    Energy Technology Data Exchange (ETDEWEB)

    Khalil, A.; Le Breton, C.; Tassart, M.; Korzec, J.; Bigot, J.M.; Carette, M.F. [Department of Radiology, Tenon Hospital, Paris (France)

    1999-10-01

    The objective of this study was to determine the utility of CT scan findings for the diagnosis of chest wall tuberculosis, excluding the spine. We reviewed 15 patients (13 Africans and 2 Indians) with chest wall tuberculosis, retrospectively. The radiologic examination consisted of a plain X-ray and a CT scan of the chest for each patient. The site of disease was the rib in 13 patients or the body of the sternum in 2 patients. One rib was involved in 11 patients, 2 contiguous ribs (one site) in 2 patients, and bilateral disease (two sites) was observed in the remaining patient. The 14 rib sites involved the posterior arc or costovertebral joint in 11 cases, the anterior arc in 2 cases, and the anterior and middle arc in 1 case. The CT scan findings were an abscess (n = 14) or a soft tissue mass (n = 2), osteolytic lesions (n = 13), periosteal reaction (n = 10), and sequestrum (n = 14). Bone sclerosis was observed only in 3 cases of rib involvement. The association of a soft tissue abscess, an osteolytic lesion, and sequestrum, especially in immigrants to France, suggests chest wall tuberculosis on CT scan. (orig.) With 5 figs., 2 tabs., 11 refs.

  9. Correlations between Energy and Displacement Demands for Performance-Based Seismic Engineering

    Science.gov (United States)

    Mollaioli, Fabrizio; Bruno, Silvia; Decanini, Luis; Saragoni, Rodolfo

    2011-01-01

    The development of a scientific framework for performance-based seismic engineering requires, among other steps, the evaluation of ground motion intensity measures at a site and the characterization of their relationship with suitable engineering demand parameters (EDPs) which describe the performance of a structure. In order to be able to predict the damage resulting from earthquake ground motions in a structural system, it is first necessary to properly identify ground motion parameters that are well correlated with structural response and, in turn, with damage. Since structural damage during an earthquake ground motion may be due to excessive deformation or to cumulative cyclic damage, reliable methods for estimating displacement demands on structures are needed. Even though the seismic performance is directly related to the global and local deformations of the structure, energy-based methodologies appear more helpful in concept, as they permit a rational assessment of the energy absorption and dissipation mechanisms that can be effectively accomplished to balance the energy imparted to the structure. Moreover, energy-based parameters are directly related to cycles of response of the structure and, therefore, they can implicitly capture the effect of ground motion duration, which is ignored by conventional spectral parameters. Therefore, the identification of reliable relationships between energy and displacement demands represents a fundamental issue in both the development of more reliable seismic code provisions and the evaluation of seismic vulnerability aimed at the upgrading of existing hazardous facilities. As these two aspects could become consistently integrated within a performance-based seismic design methodology, understanding how input and dissipated energy are correlated with displacement demands emerges as a decisive prerequisite. The aim of the present study is the establishment of functional relationships between input and dissipated energy

  10. Displacement of the hip center of rotation after arthroplasty of Crowe III and IV dysplasia: a radiological and biomechanical study.

    Science.gov (United States)

    Abolghasemian, Mansour; Samiezadeh, Saeid; Jafari, Davood; Bougherara, Habiba; Gross, Allan E; Ghazavi, Mohammad T

    2013-06-01

    To study the direction and biomechanical consequences of hip center of rotation (HCOR) migration in Crowe type III and VI hips after total hip arthroplasty, post-operative radiographs and CT scans of several unilaterally affected hips were evaluated. Using a three-dimensional model of the human hip, the HCOR was moved in all directions, and joint reaction force (JRF) and abductor muscle force (AMF) were calculated for single-leg stance configuration. Comparing to the normal side, HCOR had displaced medially and inferiorly by an average of 23.4% and 20.8%, respectively, of the normal femoral head diameter. Significant decreases in JRF (13%) and AMF (46.13%) were observed in a presumptive case with that amount of displacement. Isolated inferior displacement had a small, increasing effect on these forces. In Crowe type III and IV hips, the HCOR migrates inferiorly and medially after THA, resulting in a decrease in JRF, AMF, and abductor muscle contraction force. Copyright © 2013 Elsevier Inc. All rights reserved.

  11. Foreign body extraction from soft tissue by using CT and fluoroscopic guidance: a new technique

    Energy Technology Data Exchange (ETDEWEB)

    Amoretti, Nicolas; Marcy, Pierre-Yves; Lesbats-Jacquot, Virginie; Fonquerne, Marie-Eve; Maratos, Yvonne [Centre Hospitalier Universitaire de Nice, Radiology Department, Nice (France); Hauger, Olivier [Hopital Pellegrin, Unite d' Imagerie Osteo-articulaire, CHU de Bordeaux (France); Hovorka, Istvan; Boileau, Pascal [Centre Hopitalier Universitaire de Nice, Orthopaedic Department, Nice (France)

    2010-01-15

    We report on a new minimally invasive technique for the retrieval of a surgical pin fragment after accidental migration into the soft tissue of the shoulder in two patients. The technique is performed under local anaesthesia and uses combined CT and fluoroscopic guidance. The materials used were simple, combining a bone biopsy needle and an endoscopy clamp. Pin displacement was confirmed under fluoroscopic guidance and the clamp was used to withdraw the pin to the cutaneous entry point under CT (step-by-step) guidance. The CT slices provide perfect visualisation of the vascular or nervous structures as well as perfect positioning of the extremity of the trocar relative to the material to be removed. This intervention avoids a second surgical intervention with a longer incision and avoided repeated general anaesthesia. (orig.)

  12. Non-rigid CT/CBCT to CBCT registration for online external beam radiotherapy guidance

    Science.gov (United States)

    Zachiu, Cornel; de Senneville, Baudouin Denis; Tijssen, Rob H. N.; Kotte, Alexis N. T. J.; Houweling, Antonetta C.; Kerkmeijer, Linda G. W.; Lagendijk, Jan J. W.; Moonen, Chrit T. W.; Ries, Mario

    2018-01-01

    Image-guided external beam radiotherapy (EBRT) allows radiation dose deposition with a high degree of accuracy and precision. Guidance is usually achieved by estimating the displacements, via image registration, between cone beam computed tomography (CBCT) and computed tomography (CT) images acquired at different stages of the therapy. The resulting displacements are then used to reposition the patient such that the location of the tumor at the time of treatment matches its position during planning. Moreover, ongoing research aims to use CBCT-CT image registration for online plan adaptation. However, CBCT images are usually acquired using a small number of x-ray projections and/or low beam intensities. This often leads to the images being subject to low contrast, low signal-to-noise ratio and artifacts, which ends-up hampering the image registration process. Previous studies addressed this by integrating additional image processing steps into the registration procedure. However, these steps are usually designed for particular image acquisition schemes, therefore limiting their use on a case-by-case basis. In the current study we address CT to CBCT and CBCT to CBCT registration by the means of the recently proposed EVolution registration algorithm. Contrary to previous approaches, EVolution does not require the integration of additional image processing steps in the registration scheme. Moreover, the algorithm requires a low number of input parameters, is easily parallelizable and provides an elastic deformation on a point-by-point basis. Results have shown that relative to a pure CT-based registration, the intrinsic artifacts present in typical CBCT images only have a sub-millimeter impact on the accuracy and precision of the estimated deformation. In addition, the algorithm has low computational requirements, which are compatible with online image-based guidance of EBRT treatments.

  13. Influence of chamber misalignment on cased telescoped (CT ammunition accuracy

    Directory of Open Access Journals (Sweden)

    D. Corriveau

    2016-04-01

    Full Text Available As part of a research program, it was desired to better understand the impact of the rotating chamber alignment with the barrel throat on the precision and accuracy of a novel cased telescoped (CT ammunition firing rifle. In order to perform the study, a baseline CT ammunition chamber which was concentric with a Mann barrel bore was manufactured. Additionally, six chambers were manufactured with an offset relative to the barrel bore. These chambers were used to simulate a misaligned chamber relative to the bore axis. Precision and accuracy tests were then performed at 200 m in an indoor range under controlled conditions. For this project, 5.56 mm CT ammunition was used. As the chamber axis offset relative to the gun bore was increased, the mean point of impact was displaced away from the target center. The shift in the impact location is explained by the presence of in-bore yaw which results in lateral throw-off and aerodynamic jump components. The linear theory of ballistics is used to establish a relationship between the chamber misalignment and the resulting projectile mean point of impact for a rifle developed to fire CT ammunition. This relationship allows for the prediction of the mean point of impact given a chamber misalignment.

  14. Multimodal Registration of gated cardiac PET, CT and MR sequences

    International Nuclear Information System (INIS)

    Baty, X.

    2007-07-01

    The research described in this manuscript deals with the multimodal registration of cardiac images from Magnetic Resonance Imaging (MRI), Position Emission Tomography (PET) and Computerized Tomography (CT). All these modalities are gated to the Electrocardiogram (ECG) and provide information to evaluate cardiac function, and to diagnose and to follow-up cardiovascular pathologies. PET imaging allows the evaluation of ventricular function and MRI is a gold standard for the study of the left ventricular function. The goal of our registration process is to merge functional (from PET) and anatomical images (from CT and MRI). Our process is adapted to the modalities used and is divided in two steps: (i) a global rigid 3-dimensional model-based ICP (Iterative Closest Point) registration between CT and MR data and (ii) an iconic 2-dimensional registration based on Free Form Deformations and Mutual Information. This last step presents an original contribution by using a composite image of CT (which presents epicardic contours) and PET (where endocardic contours are partially visible) data to make mutual information more accurate in representing the similarity with the MR data. To speed up the whole process, we also present a transformation initialization scheme using displacement field obtained form MR data only. The obtained results have been evaluated by experts. (author)

  15. CT of the chest in suspected child abuse using submillisievert radiation dose

    International Nuclear Information System (INIS)

    Sanchez, Thomas R.; Seibert, J.A.; Stein-Wexler, Rebecca; Lee, Justin S.; Coulter, Kevin P.

    2015-01-01

    The cornerstone of child abuse imaging is the skeletal survey, but initial imaging with radiographs may not demonstrate acute and non-displaced fractures, especially those involving the ribs. Given the high mortality of undiagnosed non-accidental trauma, timely diagnosis is crucial. CT is more sensitive in assessing rib fractures; however the effective radiation dose of a standard chest CT is high. We retrospectively identified four children (three boys, one girl; age range 1-4 months) admitted between January 2013 and February 2014 with high suspicion for non-accidental trauma from unexplained fractures of the long bones; these children all had CT of the chest when no rib fractures were evident on the skeletal survey. The absorbed radiation dose estimates for organs and tissue from the four-view chest radiographs and subsequent CT were determined using Monte Carlo photon transport software, and the effective dose was calculated using published tissue-weighting factors. In two children, CT showed multiple fractures of the ribs, scapula and vertebral body that were not evident on the initial skeletal survey. The average effective dose for a four-view chest radiograph across the four children was 0.29 mSv and the average effective dose for the chest CT was 0.56 mSv. Therefore the effective dose of a chest CT is on average less than twice that of a four-view chest radiograph. Our protocol thus shows that a reduced-dose chest CT may be useful in the evaluation of high specificity fractures of non-accidental trauma when the four-view chest radiographs are negative. (orig.)

  16. CT of the chest in suspected child abuse using submillisievert radiation dose

    Energy Technology Data Exchange (ETDEWEB)

    Sanchez, Thomas R.; Seibert, J.A.; Stein-Wexler, Rebecca [Medical Center Children' s Hospital, Division of Pediatric Radiology, University of California-Davis, Sacramento, CA (United States); Lee, Justin S. [University of California-Davis, Department of Radiology, Sacramento, CA (United States); Coulter, Kevin P. [Medical Center Children' s Hospital, Department of Pediatrics, University of California-Davis, Sacramento, CA (United States)

    2015-07-15

    The cornerstone of child abuse imaging is the skeletal survey, but initial imaging with radiographs may not demonstrate acute and non-displaced fractures, especially those involving the ribs. Given the high mortality of undiagnosed non-accidental trauma, timely diagnosis is crucial. CT is more sensitive in assessing rib fractures; however the effective radiation dose of a standard chest CT is high. We retrospectively identified four children (three boys, one girl; age range 1-4 months) admitted between January 2013 and February 2014 with high suspicion for non-accidental trauma from unexplained fractures of the long bones; these children all had CT of the chest when no rib fractures were evident on the skeletal survey. The absorbed radiation dose estimates for organs and tissue from the four-view chest radiographs and subsequent CT were determined using Monte Carlo photon transport software, and the effective dose was calculated using published tissue-weighting factors. In two children, CT showed multiple fractures of the ribs, scapula and vertebral body that were not evident on the initial skeletal survey. The average effective dose for a four-view chest radiograph across the four children was 0.29 mSv and the average effective dose for the chest CT was 0.56 mSv. Therefore the effective dose of a chest CT is on average less than twice that of a four-view chest radiograph. Our protocol thus shows that a reduced-dose chest CT may be useful in the evaluation of high specificity fractures of non-accidental trauma when the four-view chest radiographs are negative. (orig.)

  17. The intercomparison of standardized patients anatomy and organs topography with CT-scanning results

    International Nuclear Information System (INIS)

    Breit, A.; Lindner, H.; Pfaendner, K.

    1981-01-01

    Using CT-studies for therapy planning gives some new and important aspects in the anatomy of different organs. Visualization of the kidneys in prone or supine positions shows that moderate displacement ventrally may occur which has to be taken into account in isodose distribution. Topographical cross-sections of the kidney based on various drawings comprise considerable sources of errors. Examination of bowel loops taken in prone and supine positions as well as at different days, however, show for radiation therapy only minor differences. CT enables us to exactly comprehend the position of the uterus and thereby the isodoses for intracavitary therapy. Evaluation of the individual thickness of the thoracic wall by CT allows in cases with mamma carcinoma optimization of radiotherapy technique. Additional information as fas as topography of different organs is concerned may be gained by angio-CT. With the help of a computer precise therapy plans can be drawn up knowing the exact individual anatomy and can be realized to the benefit of the patient. (orig.)

  18. Interaction of norfloxacin with bovine serum albumin studied by different spectrometric methods; displacement studies, molecular modeling and chemometrics approaches

    Energy Technology Data Exchange (ETDEWEB)

    Naseri, Abdolhossein, E-mail: a_naseri@tabrizu.ac.ir [Departments of Analytical Chemistry, Faculty of Chemistry, University of Tabriz, Tabriz 51666-16471 (Iran, Islamic Republic of); Hosseini, Soheila [Departments of Analytical Chemistry, Faculty of Chemistry, University of Tabriz, Tabriz 51666-16471 (Iran, Islamic Republic of); Rasoulzadeh, Farzaneh [Drug Applied Research Center, Tabriz University of Medical Sciences, Tabriz 51644-14766 (Iran, Islamic Republic of); Rashidi, Mohammad-Reza [Research Center for Pharmaceutical Nanotechnology, Tabriz University of Medical Sciences, Tabriz 51644-14766 (Iran, Islamic Republic of); Zakery, Maryam; Khayamian, Taghi [Department of Chemistry, College of Chemistry, Isfahan University of Technology, Isfahan 84154 (Iran, Islamic Republic of)

    2015-01-15

    Serum albumins as major target proteins can bind to other ligands leading to alteration of their pharmacological properties. The mechanism of interaction between norfloxacin (NFLX) with bovine serum albumin (BSA) was investigated. Fuorescence quenching of serum albumin by this drug was found to be a static quenching process. The binding sites number, n, apparent binding constant, K, and thermodynamic parameters were calculated at different temperatures. The distance, r, between donor, BSA, and acceptor, NFLX, was calculated according to the Forster theory of non-radiation energy transfer. Also binding characteristics of NFLX with BSA together with its displacement from its binding site by kanamycin and effect of common metal ions on binding constant were investigated by the spectroscopic methods. The conformational change in the secondary structure of BSA upon interaction with NFLX was investigated qualitatively from synchronous fluorescence spectra, Fourier Transform Infrared (FTIR) and circular dichroism (CD) spectrometric methods. Molecular docking studies were performed to obtain information on the possible residues involved in the interaction process and changes in accessible surface area of the interacting residues. The results showed that the conformation of BSA changed in the presence of NFLX. For the first time, displacement studies were used for this interaction; displacement studies showed that NFLX was displaced by phenylbutazon and ketoprofen but was not displaced by ibuprofen indicating that the binding site of NFLX on albumin was site I. In addition a powerful chemometrics method, multivariate curve resolution-alternating least square, was used for resolution of spectroscopic augmented data obtained in two different titration modes in order to extract spectral information regardless of spectral overlapping of components. - Highlights: • Interaction between norfloxacin and BSA is studied by spectral methods. • Chemometrics methods are used to

  19. Double displacement: An improved bioorthogonal reaction strategy for templated nucleic acid detection.

    Science.gov (United States)

    Kleinbaum, Daniel J; Miller, Gregory P; Kool, Eric T

    2010-06-16

    Quenched autoligation probes have been employed previously in a target-templated nonenzymatic ligation strategy for detecting nucleic acids in cells by fluorescence. A common source of background signal in such probes is the undesired reaction with water and other cellular nucleophiles. Here, we describe a new class of self-ligating probes, double displacement (DD) probes, that rely on two displacement reactions to fully unquench a nearby fluorophore. Three potential double displacement architectures, all possessing two fluorescence quencher/leaving groups (dabsylate groups), were synthesized and evaluated for templated reaction with nucleophile (phosphorothioate) probes both in vitro and in intact bacterial cells. All three DD probe designs provided substantially better initial quenching than a single-Dabsyl control. In isothermal templated reactions in vitro, double displacement probes yielded considerably lower background signal than previous single displacement probes; investigation into the mechanism revealed that one dabsylate acts as a sacrificial leaving group, reacting nonspecifically with water, but yielding little signal because another quencher group remains. Templated reaction with the specific nucleophile probe is required to activate a signal. The double displacement probes provided a ca. 80-fold turn-on signal and yielded a 2-4-fold improvement in signal/background over single Dabsyl probes. The best-performing probe architecture was demonstrated in a two-color, FRET-based two-allele discrimination system in vitro and was shown to be capable of discriminating between two closely related species of bacteria differing by a single nucleotide at an rRNA target site.

  20. CT diagnosis of invasive hydatidiform mole

    International Nuclear Information System (INIS)

    Lu Mingquan; Jiang Lina; Li Xianxing; Wang Peijun

    2000-01-01

    Objective: To investigate the CT features and the diagnostic value in invasive mole. Methods: Eleven cases (age, 30 to 53 years, mean 40 years) with invasive mole proved by operation and pathology were studied, including 3 cases during peri-menopausal period of eight months, ten months and twelve months respectively. All cases were scanned by CT and enhanced study was done. Results: All cases showed enlargement of uterus of varying degrees. On CT, the density of uterine cavity was similar to that of water, intermingled with spotty patchy and hazy circular isodense shadows. High density stripe-like bleeding foci were found in 3 cases. The outline of uterine cavity was locally disrupted in all case and the muscle layer was thickened in 3 cases. On enhanced CT scan, the lesions in the uterine cavity appeared markedly hyperdense, just like 'the crater' and the 'mole sign'. The muscle layers at the site of disruption showed inhomogeneous enhancement after contrast injection. Conclusion: The CT features of invasive mole are characteristic, with important diagnostic value, especially for those during peri-menopausal period

  1. Deformable image registration based automatic CT-to-CT contour propagation for head and neck adaptive radiotherapy in the routine clinical setting.

    Science.gov (United States)

    Kumarasiri, Akila; Siddiqui, Farzan; Liu, Chang; Yechieli, Raphael; Shah, Mira; Pradhan, Deepak; Zhong, Hualiang; Chetty, Indrin J; Kim, Jinkoo

    2014-12-01

    To evaluate the clinical potential of deformable image registration (DIR)-based automatic propagation of physician-drawn contours from a planning CT to midtreatment CT images for head and neck (H&N) adaptive radiotherapy. Ten H&N patients, each with a planning CT (CT1) and a subsequent CT (CT2) taken approximately 3-4 week into treatment, were considered retrospectively. Clinically relevant organs and targets were manually delineated by a radiation oncologist on both sets of images. Four commercial DIR algorithms, two B-spline-based and two Demons-based, were used to deform CT1 and the relevant contour sets onto corresponding CT2 images. Agreement of the propagated contours with manually drawn contours on CT2 was visually rated by four radiation oncologists in a scale from 1 to 5, the volume overlap was quantified using Dice coefficients, and a distance analysis was done using center of mass (CoM) displacements and Hausdorff distances (HDs). Performance of these four commercial algorithms was validated using a parameter-optimized Elastix DIR algorithm. All algorithms attained Dice coefficients of >0.85 for organs with clear boundaries and those with volumes >9 cm(3). Organs with volumes <3 cm(3) and/or those with poorly defined boundaries showed Dice coefficients of ∼ 0.5-0.6. For the propagation of small organs (<3 cm(3)), the B-spline-based algorithms showed higher mean Dice values (Dice = 0.60) than the Demons-based algorithms (Dice = 0.54). For the gross and planning target volumes, the respective mean Dice coefficients were 0.8 and 0.9. There was no statistically significant difference in the Dice coefficients, CoM, or HD among investigated DIR algorithms. The mean radiation oncologist visual scores of the four algorithms ranged from 3.2 to 3.8, which indicated that the quality of transferred contours was "clinically acceptable with minor modification or major modification in a small number of contours." Use of DIR-based contour propagation in the routine

  2. Deformable image registration based automatic CT-to-CT contour propagation for head and neck adaptive radiotherapy in the routine clinical setting

    International Nuclear Information System (INIS)

    Kumarasiri, Akila; Siddiqui, Farzan; Liu, Chang; Yechieli, Raphael; Shah, Mira; Pradhan, Deepak; Zhong, Hualiang; Chetty, Indrin J.; Kim, Jinkoo

    2014-01-01

    Purpose: To evaluate the clinical potential of deformable image registration (DIR)-based automatic propagation of physician-drawn contours from a planning CT to midtreatment CT images for head and neck (H and N) adaptive radiotherapy. Methods: Ten H and N patients, each with a planning CT (CT1) and a subsequent CT (CT2) taken approximately 3–4 week into treatment, were considered retrospectively. Clinically relevant organs and targets were manually delineated by a radiation oncologist on both sets of images. Four commercial DIR algorithms, two B-spline-based and two Demons-based, were used to deform CT1 and the relevant contour sets onto corresponding CT2 images. Agreement of the propagated contours with manually drawn contours on CT2 was visually rated by four radiation oncologists in a scale from 1 to 5, the volume overlap was quantified using Dice coefficients, and a distance analysis was done using center of mass (CoM) displacements and Hausdorff distances (HDs). Performance of these four commercial algorithms was validated using a parameter-optimized Elastix DIR algorithm. Results: All algorithms attained Dice coefficients of >0.85 for organs with clear boundaries and those with volumes >9 cm 3 . Organs with volumes <3 cm 3 and/or those with poorly defined boundaries showed Dice coefficients of ∼0.5–0.6. For the propagation of small organs (<3 cm 3 ), the B-spline-based algorithms showed higher mean Dice values (Dice = 0.60) than the Demons-based algorithms (Dice = 0.54). For the gross and planning target volumes, the respective mean Dice coefficients were 0.8 and 0.9. There was no statistically significant difference in the Dice coefficients, CoM, or HD among investigated DIR algorithms. The mean radiation oncologist visual scores of the four algorithms ranged from 3.2 to 3.8, which indicated that the quality of transferred contours was “clinically acceptable with minor modification or major modification in a small number of contours.” Conclusions

  3. Deformable image registration based automatic CT-to-CT contour propagation for head and neck adaptive radiotherapy in the routine clinical setting

    Energy Technology Data Exchange (ETDEWEB)

    Kumarasiri, Akila, E-mail: akumara1@hfhs.org; Siddiqui, Farzan; Liu, Chang; Yechieli, Raphael; Shah, Mira; Pradhan, Deepak; Zhong, Hualiang; Chetty, Indrin J.; Kim, Jinkoo [Department of Radiation Oncology, Henry Ford Health System, Detroit, Michigan 48202 (United States)

    2014-12-15

    Purpose: To evaluate the clinical potential of deformable image registration (DIR)-based automatic propagation of physician-drawn contours from a planning CT to midtreatment CT images for head and neck (H and N) adaptive radiotherapy. Methods: Ten H and N patients, each with a planning CT (CT1) and a subsequent CT (CT2) taken approximately 3–4 week into treatment, were considered retrospectively. Clinically relevant organs and targets were manually delineated by a radiation oncologist on both sets of images. Four commercial DIR algorithms, two B-spline-based and two Demons-based, were used to deform CT1 and the relevant contour sets onto corresponding CT2 images. Agreement of the propagated contours with manually drawn contours on CT2 was visually rated by four radiation oncologists in a scale from 1 to 5, the volume overlap was quantified using Dice coefficients, and a distance analysis was done using center of mass (CoM) displacements and Hausdorff distances (HDs). Performance of these four commercial algorithms was validated using a parameter-optimized Elastix DIR algorithm. Results: All algorithms attained Dice coefficients of >0.85 for organs with clear boundaries and those with volumes >9 cm{sup 3}. Organs with volumes <3 cm{sup 3} and/or those with poorly defined boundaries showed Dice coefficients of ∼0.5–0.6. For the propagation of small organs (<3 cm{sup 3}), the B-spline-based algorithms showed higher mean Dice values (Dice = 0.60) than the Demons-based algorithms (Dice = 0.54). For the gross and planning target volumes, the respective mean Dice coefficients were 0.8 and 0.9. There was no statistically significant difference in the Dice coefficients, CoM, or HD among investigated DIR algorithms. The mean radiation oncologist visual scores of the four algorithms ranged from 3.2 to 3.8, which indicated that the quality of transferred contours was “clinically acceptable with minor modification or major modification in a small number of contours

  4. CT diagnosis of neuroblastoma in childhood

    International Nuclear Information System (INIS)

    Li Xin; Zhang Liqun; Yang Zhiyong

    1997-01-01

    Purpose: To evaluate CT in the diagnosis of neuroblastoma in childhood. Materials and methods: Analysis of CT manifestations in 26 cases proved by operation and pathology, including neuroblastoma 21 cases, ganglioneuroblastoma 5 cases. Thorax 7 cases (27%), adrenal gland 16 cases (62%), abdomen-pelvis paravertebral sympathetic chain 3 cases (11%). Bolus injection of contrast medium was given in all cases. Results: Adrenal gland and posterior superior mediastinum were the most common sites for neuroblastoma. 73% of neuroblastoma had calcifications. Neuroblastoma was more commonly calcified than ganglioneuroblastoma. Metastases were also calcified. Degree of enhancement was associated with the type of neuroblastoma. Tumor extension into the spinal canal was seen in 2 cases. 43% neuroblastoma of adrenal directly invaded the kidney in 7 cases. Right lobe of liver was involved in 3 cases, metastases to liver in 1 case, enlargement of lymph nodes 19 cases. Approximately 68% of patients showed increase of urinary Vanilly-mandelic acid (VMA). Preoperative diagnostic accuracy was 92%. Conclusion: CT is recognized as a useful technique for the diagnosis of neuroblastoma. The site of predilection, calcification, lymph node metastases and VMA increase in urine or serum are important basis for diagnosis

  5. Intraobserver and Interobserver Variability in GTV Delineation on FDG-PET-CT Images of Head and Neck Cancers

    International Nuclear Information System (INIS)

    Breen, Stephen L.; Publicover, Julia; De Silva, Shiroma; Pond, Greg; Brock, Kristy; O'Sullivan, Brian; Cummings, Bernard; Dawson, Laura; Keller, Anne; Kim, John; Ringash, Jolie; Yu, Eugene; Hendler, Aaron; Waldron, John

    2007-01-01

    Purpose: To determine if the addition of fluorodeoxyglucose positron emission tomography (FDG-PET) data changes primary site gross tumor volumes (GTVs) in head and neck cancers. Methods and Materials: Computed tomography (CT), contrast-enhanced CT, and FDG-PET-CT scans were obtained in 10 patients with head and neck cancers. Eight experienced observers (6 head and neck oncologists and 2 neuro-radiologists) with access to clinical and radiologic reports outlined primary site GTVs on each modality. Three cases were recontoured twice to assess intraobserver variability. The magnitudes of the GTVs were compared. Intra- and interobserver variability was assessed by a two-way repeated measures analysis of variance. Inter- and intraobserver reliability were calculated. Results: There were no significant differences in the GTVs across the image modalities when compared as ensemble averages; the Wilcoxon matched-pairs signed-rank test showed that CT volumes were larger than PET-CT. Observers demonstrated the greatest consistency and were most interchangeable on contrast-enhanced CT; they performed less reliably on PET-CT. Conclusions: The addition of PET-CT to primary site GTV delineation of head and neck cancers does not change the volume of the GTV defined by this group of expert observers in this patient sample. An FDG-PET may demonstrate differences in neck node delineation and in other disease sites

  6. Interesting cases which were difficult to diagnose by CT

    International Nuclear Information System (INIS)

    Ueki, Koji; Okubo, Koichi; Shinohara, Shinji

    1981-01-01

    Computed tomography (CT) clinically provides us with much more useful diagnostic informations regarding the localization, size, shape, extent and inner structure of the lesions and then in some cases the specific diagnosis can be also obtained by CT alone. However, it is usually difficult to define the longitudinal extent of the lesions, their relation to adjacent tissues, the originated site in enormous lesion and histological type also. At CT examination, it is essential to recognize these drawback and limitation on CT. From these points of view, six interesting cases (i.e. pericardial diverticulum, hepatoma with retroperitoneal metastasis, cholangiohepatoma, afferent loop syndrome, invagination and retroperitoneal malignant schwannoma) which were difficult to diagnose by CT and proved ultimately with operation or autopsy were illustrated with some reviews. (author)

  7. Harmane and harmalan are bioactive components of classical clonidine-displacing substance.

    Science.gov (United States)

    Parker, Christine A; Anderson, Neil J; Robinson, Emma S J; Price, Rhiannon; Tyacke, Robin J; Husbands, Stephen M; Dillon, Michael P; Eglen, Richard M; Hudson, Alan L; Nutt, David J; Crump, Matthew P; Crosby, John

    2004-12-28

    Elucidation of the structure of the endogenous ligand(s) for imidazoline binding sites, clonidine-displacing substance (CDS), has been a major goal for many years. Crude CDS from bovine lung was purified by reverse-phase high-pressure liquid chromatography. Electrospray mass spectrometry (ESMS) and nuclear magnetic resonance ((1)H NMR) analysis revealed the presence of L-tryptophan and 1-carboxy-1-methyltetrahydro-beta-carboline in the active CDS extract. Competition radioligand binding studies, however, failed to show displacement of specific [(3)H]clonidine binding to rat brain membranes for either compound. Further purification of the bovine lung extract allowed the isolation of the beta-carbolines harmane and harmalan as confirmed by ESMS, (1)H NMR, and comparison with synthetic standards. Both compounds exhibited a high (nanomolar) affinity for both type 1 and type 2 imidazoline binding sites, and the synthetic standards were shown to coelute with the active classical CDS extracts. We therefore propose that the beta-carbolines harmane and harmalan represent active components of classical CDS. The identification of these compounds will allow us to establish clear physiological roles for CDS.

  8. CT staging of colon cancer

    International Nuclear Information System (INIS)

    Dighe, S.; Swift, I.; Brown, G.

    2008-01-01

    Computer tomography (CT) has been the principal investigation in the staging of colon cancers. The information obtained with routine CT has been limited to identifying the site of the tumour, size of the tumour, infiltration into surrounding structures and metastatic spread. The Foxtrot trial National Cancer Research Institute (NCRI) has been specifically designed to evaluate the efficacy of neoadjuvant treatment in colon cancers by using preoperative chemotherapy with or without an anti-Epidermal Growth Factor Receptor (EGFR) monoclonal antibody to improve outcome in high-risk operable colon cancer. Patients are selected based on their staging CT examination. The criteria for poor prognosis are T4 and T3 tumours with more than 5 mm extramural depth. Thus the success of the trial would depend upon the confidence of the radiologist to identify the patients that would receive the neoadjuvant treatment. The aim of this review is to explain the process of identifying high-risk features seen on the staging CT images. This will help to identify a cohort of patients that could truly benefit from neoadjuvant strategies

  9. CT staging of colon cancer

    Energy Technology Data Exchange (ETDEWEB)

    Dighe, S. [Department of Radiology, Royal Marsden Hospital, Sutton SM5 2TT (United Kingdom); Swift, I. [Department of Surgery, Mayday University Hospital, Croydon CR7 7YE (United Kingdom); Brown, G. [Department of Radiology, Royal Marsden Hospital, Sutton SM5 2TT (United Kingdom)], E-mail: gina.brown@rmh.nhs.uk

    2008-12-15

    Computer tomography (CT) has been the principal investigation in the staging of colon cancers. The information obtained with routine CT has been limited to identifying the site of the tumour, size of the tumour, infiltration into surrounding structures and metastatic spread. The Foxtrot trial National Cancer Research Institute (NCRI) has been specifically designed to evaluate the efficacy of neoadjuvant treatment in colon cancers by using preoperative chemotherapy with or without an anti-Epidermal Growth Factor Receptor (EGFR) monoclonal antibody to improve outcome in high-risk operable colon cancer. Patients are selected based on their staging CT examination. The criteria for poor prognosis are T4 and T3 tumours with more than 5 mm extramural depth. Thus the success of the trial would depend upon the confidence of the radiologist to identify the patients that would receive the neoadjuvant treatment. The aim of this review is to explain the process of identifying high-risk features seen on the staging CT images. This will help to identify a cohort of patients that could truly benefit from neoadjuvant strategies.

  10. Neck after total laryngectomy: CT study

    International Nuclear Information System (INIS)

    DiSantis, D.J.; Balfe, D.M.; Hayden, R.E.; Sagel, S.S.; Sessions, D.; Lee, J.K.T.

    1984-01-01

    Computed tomographic scans in 23 patients who had undergone total laryngectomy were analyzed retrospectively to determine normal postoperative appearance and to evaluate the role of CT in assessing recurrent neoplasm. Nine patients without clinical evidence of recurrence illustrated the normal postoperative changes: a round or ovoid neopharynx connecting the base of the tongue with the cervical esophagus and intact fat planes surrounding the neopharynx, neurovascular bundles, and sternocleidomastoid muscles. In the 12 patients with recurrent neoplasm, the CT manifestations included masses involving the internal jugular lymph node chain, tracheostomy site, or paratracheal region. CT supplemented physical examination and indirect mirror examination, providing data regarding presence and extent of recurrent tumor and aiding in planning the mode and scope of therapy

  11. Emergencies in the retroperitoneum: assessment of spread of disease by helical CT

    Energy Technology Data Exchange (ETDEWEB)

    Scialpi, M. E-mail: michelescialpi@libero.it; Scaglione, M.; Angelelli, G.; Lupattelli, L.; Resta, M.C.; Resta, M.; Rotondo, A

    2004-04-01

    Acute pancreatitis, leaking abdominal aortic aneurysm, and renal trauma frequently occur in the setting of patients with abdominal nontraumatic and traumatic injury; it represents the most urgent conditions that may determine the presence of fluid collections or haematoma in the retroperitoneum. Single spiral CT and multidetector-row CT (MDCT) play an important role in diagnosis of retroperitoneal emergencies, providing useful informations on the type, site, extent and management of the fluid collections. An accurate CT assessment requires the awareness of the existence of dissectable retroperitoneal fascial planes. Fluid collections or haematoma tends to escape the retroperitoneal site of origin into planes extend from the diaphragm to the pelvic floor. We assess the multicompartimental anatomy of the retroperitoneum and the pathway of spread of the most frequent retroperitoneal fluid collections or haematoma by helical CT.

  12. The use of a displacement device negatively affects the performance of dogs (Canis familiaris) in visible object displacement tasks.

    Science.gov (United States)

    Müller, Corsin A; Riemer, Stefanie; Range, Friederike; Huber, Ludwig

    2014-08-01

    Visible and invisible displacement tasks have been used widely for comparative studies of animals' understanding of object permanence, with evidence accumulating that some species can solve invisible displacement tasks and, thus, reach Piagetian stage 6 of object permanence. In contrast, dogs appear to rely on associative cues, such as the location of the displacement device, during invisible displacement tasks. It remains unclear, however, whether dogs, and other species that failed in invisible displacement tasks, do so because of their inability to form a mental representation of the target object, or simply because of the involvement of a more salient but potentially misleading associative cue, the displacement device. Here we show that the use of a displacement device impairs the performance of dogs also in visible displacement tasks: their search accuracy was significantly lower when a visible displacement was performed with a displacement device, and only two of initially 42 dogs passed the sham-baiting control conditions. The negative influence of the displacement device in visible displacement tasks may be explained by strong associative cues overriding explicit information about the target object's location, reminiscent of an overshadowing effect, and/or object individuation errors as the target object is placed within the displacement device and moves along a spatiotemporally identical trajectory. Our data suggest that a comprehensive appraisal of a species' performance in object permanence tasks should include visible displacement tasks with the same displacement device used in invisible displacements, which typically has not been done in the past.

  13. In vivo verification of proton beam path by using post-treatment PET/CT imaging.

    Science.gov (United States)

    Hsi, Wen C; Indelicato, Daniel J; Vargas, Carlos; Duvvuri, Srividya; Li, Zuofeng; Palta, Jatinder

    2009-09-01

    The purpose of this study is to establish the in vivo verification of proton beam path by using proton-activated positron emission distributions. A total of 50 PET/CT imaging studies were performed on ten prostate cancer patients immediately after daily proton therapy treatment through a single lateral portal. The PET/CT and planning CT were registered by matching the pelvic bones, and the beam path of delivered protons was defined in vivo by the positron emission distribution seen only within the pelvic bones, referred to as the PET-defined beam path. Because of the patient position correction at each fraction, the marker-defined beam path, determined by the centroid of implanted markers seen in the posttreatment (post-Tx) CT, is used for the planned beam path. The angular variation and discordance between the PET- and marker-defined paths were derived to investigate the intrafraction prostate motion. For studies with large discordance, the relative location between the centroid and pelvic bones seen in the post-Tx CT was examined. The PET/CT studies are categorized for distinguishing the prostate motion that occurred before or after beam delivery. The post-PET CT was acquired after PET imaging to investigate prostate motion due to physiological changes during the extended PET acquisition. The less than 2 degrees of angular variation indicates that the patient roll was minimal within the immobilization device. Thirty of the 50 studies with small discordance, referred as good cases, show a consistent alignment between the field edges and the positron emission distributions from the entrance to the distal edge. For those good cases, average displacements are 0.6 and 1.3 mm along the anterior-posterior (D(AP)) and superior-inferior (D(SI)) directions, respectively, with 1.6 mm standard deviations in both directions. For the remaining 20 studies demonstrating a large discordance (more than 6 mm in either D(AP) or D(SI)), 13 studies, referred as motion-after-Tx cases

  14. In vivo verification of proton beam path by using post-treatment PET/CT imaging

    Energy Technology Data Exchange (ETDEWEB)

    Hsi, Wen C.; Indelicato, Daniel J.; Vargas, Carlos; Duvvuri, Srividya; Li Zuofeng; Palta, Jatinder [Proton Therapy Institute, University of Florida, Jacksonville, Florida 32206 (United States); Boca Radiation Oncology Associates, Boca Raton, Florida 33431 (United States); Proton Therapy Institute, University of Florida, Jacksonville, Florida 32206 (United States); Department of Radiation Oncology, University of Florida, Gainesville, Florida 32610 (United States)

    2009-09-15

    Purpose: The purpose of this study is to establish the in vivo verification of proton beam path by using proton-activated positron emission distributions. Methods: A total of 50 PET/CT imaging studies were performed on ten prostate cancer patients immediately after daily proton therapy treatment through a single lateral portal. The PET/CT and planning CT were registered by matching the pelvic bones, and the beam path of delivered protons was defined in vivo by the positron emission distribution seen only within the pelvic bones, referred to as the PET-defined beam path. Because of the patient position correction at each fraction, the marker-defined beam path, determined by the centroid of implanted markers seen in the post-treatment (post-Tx) CT, is used for the planned beam path. The angular variation and discordance between the PET- and marker-defined paths were derived to investigate the intrafraction prostate motion. For studies with large discordance, the relative location between the centroid and pelvic bones seen in the post-Tx CT was examined. The PET/CT studies are categorized for distinguishing the prostate motion that occurred before or after beam delivery. The post-PET CT was acquired after PET imaging to investigate prostate motion due to physiological changes during the extended PET acquisition. Results: The less than 2 deg. of angular variation indicates that the patient roll was minimal within the immobilization device. Thirty of the 50 studies with small discordance, referred as good cases, show a consistent alignment between the field edges and the positron emission distributions from the entrance to the distal edge. For those good cases, average displacements are 0.6 and 1.3 mm along the anterior-posterior (D{sub AP}) and superior-inferior (D{sub SI}) directions, respectively, with 1.6 mm standard deviations in both directions. For the remaining 20 studies demonstrating a large discordance (more than 6 mm in either D{sub AP} or D{sub SI}), 13

  15. Molecular displacement of warfarin from human serum albumin by flavonoid aglycones

    International Nuclear Information System (INIS)

    Poór, Miklós; Li, Yin; Kunsági-Máté, Sándor; Petrik, József; Vladimir-Knežević, Sanda; Kőszegi, Tamás

    2013-01-01

    The well-known 4-hydroxycoumarin derivative warfarin is a widespread anticoagulant drug. Besides its strong albumin binding property warfarin has a narrow therapeutic window. Therefore, a few percent of displacement from albumin can result in serious biological consequences. The flavonoid molecular group also shows very strong plasma albumin binding characteristics occupying the same binding site. It is plausible to hypothesize that flavonoid aglycones may be able to displace warfarin from human serum albumin (HSA). In our study the competing activities of different flavone (acacetin, apigenin, chrysin, luteolin), flavonol (galangin, quercetin) and flavanone (hesperetin, naringenin) aglycones were investigated using fluorescence spectroscopy. Our results represent that flavonoids are able to displace warfarin from the surface of HSA. On the other hand, when comparing flavone or flavonol groups to flavanones the latter group seems to be much weaker competitor. These observations were also supported by calculation of stability constants. Our investigations strongly suggest that we should reckon with the described molecular displacement. However, further in vivo studies are needed to support the findings of our model system. -- Highlights: • Various flavonoids are able to displace warfarin from human serum albumin. • Flavones and flavonols are much more effective competitors than flavanones. • Even 300 nM aglycone concentrations show the interaction with 3 μM warfarin. • Flavonoid pairs show quasi-additive desorbing property. • Flavones and flavonols are much stronger competitors than the examined drugs

  16. Molecular displacement of warfarin from human serum albumin by flavonoid aglycones

    Energy Technology Data Exchange (ETDEWEB)

    Poór, Miklós [Institute of Laboratory Medicine, University of Pécs, Pécs H-7624 (Hungary); Li, Yin; Kunsági-Máté, Sándor [Department of General and Physical Chemistry, University of Pécs, Pécs H-7624 (Hungary); János Szentágothai Research Center, H-7624 Pécs (Hungary); Petrik, József [Department of Medical Biochemistry and Hematology, Faculty of Pharmacy and Biochemistry, University of Zagreb, HR-10000 Zagreb (Croatia); Vladimir-Knežević, Sanda [Department of Pharmacognosy, Faculty of Pharmacy and Biochemistry, University of Zagreb, HR-10000 Zagreb (Croatia); Kőszegi, Tamás, E-mail: koszegit@freemail.hu [Institute of Laboratory Medicine, University of Pécs, Pécs H-7624 (Hungary)

    2013-10-15

    The well-known 4-hydroxycoumarin derivative warfarin is a widespread anticoagulant drug. Besides its strong albumin binding property warfarin has a narrow therapeutic window. Therefore, a few percent of displacement from albumin can result in serious biological consequences. The flavonoid molecular group also shows very strong plasma albumin binding characteristics occupying the same binding site. It is plausible to hypothesize that flavonoid aglycones may be able to displace warfarin from human serum albumin (HSA). In our study the competing activities of different flavone (acacetin, apigenin, chrysin, luteolin), flavonol (galangin, quercetin) and flavanone (hesperetin, naringenin) aglycones were investigated using fluorescence spectroscopy. Our results represent that flavonoids are able to displace warfarin from the surface of HSA. On the other hand, when comparing flavone or flavonol groups to flavanones the latter group seems to be much weaker competitor. These observations were also supported by calculation of stability constants. Our investigations strongly suggest that we should reckon with the described molecular displacement. However, further in vivo studies are needed to support the findings of our model system. -- Highlights: • Various flavonoids are able to displace warfarin from human serum albumin. • Flavones and flavonols are much more effective competitors than flavanones. • Even 300 nM aglycone concentrations show the interaction with 3 μM warfarin. • Flavonoid pairs show quasi-additive desorbing property. • Flavones and flavonols are much stronger competitors than the examined drugs.

  17. Displacement data assimilation

    Energy Technology Data Exchange (ETDEWEB)

    Rosenthal, W. Steven [Pacific Northwest Laboratory, Richland, WA 99354 (United States); Venkataramani, Shankar [Department of Mathematics and Program in Applied Mathematics, University of Arizona, Tucson, AZ 85721 (United States); Mariano, Arthur J. [Rosenstiel School of Marine & Atmospheric Science, University of Miami, Miami, FL 33149 (United States); Restrepo, Juan M., E-mail: restrepo@math.oregonstate.edu [Department of Mathematics, Oregon State University, Corvallis, OR 97331 (United States)

    2017-02-01

    We show that modifying a Bayesian data assimilation scheme by incorporating kinematically-consistent displacement corrections produces a scheme that is demonstrably better at estimating partially observed state vectors in a setting where feature information is important. While the displacement transformation is generic, here we implement it within an ensemble Kalman Filter framework and demonstrate its effectiveness in tracking stochastically perturbed vortices.

  18. 2D-3D Registration of CT Vertebra Volume to Fluoroscopy Projection: A Calibration Model Assessment

    Directory of Open Access Journals (Sweden)

    P. Bifulco

    2010-01-01

    Full Text Available This study extends a previous research concerning intervertebral motion registration by means of 2D dynamic fluoroscopy to obtain a more comprehensive 3D description of vertebral kinematics. The problem of estimating the 3D rigid pose of a CT volume of a vertebra from its 2D X-ray fluoroscopy projection is addressed. 2D-3D registration is obtained maximising a measure of similarity between Digitally Reconstructed Radiographs (obtained from the CT volume and real fluoroscopic projection. X-ray energy correction was performed. To assess the method a calibration model was realised a sheep dry vertebra was rigidly fixed to a frame of reference including metallic markers. Accurate measurement of 3D orientation was obtained via single-camera calibration of the markers and held as true 3D vertebra position; then, vertebra 3D pose was estimated and results compared. Error analysis revealed accuracy of the order of 0.1 degree for the rotation angles of about 1 mm for displacements parallel to the fluoroscopic plane, and of order of 10 mm for the orthogonal displacement.

  19. Imaging of the jaw cysts with a dental CT software program : distinction of odontogenic keratocysts from other cysts

    International Nuclear Information System (INIS)

    Lee, Jung Man; Shin, Sang Hoon; Lee, Won Hoon; Oh, Kyu Hyen; Jung, Hak Young; Lee, Young Hwan; Sung, Nak Kwan; Jung, Duck Soo; Kim, Ok Dong

    1997-01-01

    To evaluate the usefulness of a dental CT software program in the assessment of jaw cysts and in the differentiation of odontogenic keratocysts and other cysts. Seventeen patients with proven jaw cysts(8 maxillae and 9 mandibles) were evaluated with a dental CT sofware program for location, locularity, the presence or absence of marginal scallping, and height to length ratio. For the delineation of involvement or displace-ment of neurovascular bundles, cortical erosion, perforation or expansion, and tooth root resorption by the jaw cysts, images from this program were compared to conventional images. Seventeen lesions icomprised 15 odontogenic cysts (five odontogenic keratocysts, five radicular, three residual and two dentigerous cysts) and two non-odontogenic cysts (one nasopalatine duct cyst and one postoperative maxillary cyst). Images of jaw cysts obtained with the dental CT software program delineated much more clearly than conventional images the status of neurovascular bundle and cortical bone, but there was no clear difference between the two modalities in delineating tooth root erosion. Dental CT findings of five mandibular odontogenic keratocysts were scalloped margin in all, mandibular ramus involvement in four, height to length ratio below 60% in four ,and multilocularity in two. The findings of the other 12 cysts (eight maxillae and four mandibles) were unilocularity in all, smooth inner margin in ten, height to length ratio below 60% in only two, and ramus involvement in none. A dental CT software program is an improved imaging modality for assessing jaw cysts;and findings which tend to indicate odontogenic keratocysts are marginal scalloping, mandibular ramus involvement, prominent spread along the marrow space and multilocularity

  20. Quantitative measurement of lung density with x-ray CT and positron CT, (2)

    International Nuclear Information System (INIS)

    Ito, Kengo; Ito, Masatoshi; Kubota, Kazuo

    1985-01-01

    Lung density was quantitatively measured on six diseased patients with X-ray CT (XCT) and Positron CT(PCT). The findings are as follows: In the silicosis, extravascular lung density was found to be remarkably increased compared to normals (0.29gcm -3 ), but blood volume was in normal range. In the post-irradiated lung cancers, extravascular lung density increased in the irradiated sites compared to the non-irradiated opposite sites, and blood volume varied in each case. In a patient with chronic heart failure, blood volume decreased (0.11mlcm -3 ) with increased extravascular lung density (0.23gcm -3 ). In the chronic obstructive pulmonary disease, both extravascular lung density and blood volume decreased (0.11gcm -3 and 0.10mlcm -3 respectively). Lung density measured with XCT was constantly lower than that with PCT in all cases. But changes in the values of lung density measured, correlated well with each other. In conclusion, the method presented here may clarify the etiology of the diffuse pulmonary diseases, and be used to differentiate and grade the diseases. (author)

  1. Choline-PET/CT for imaging prostate cancer; Cholin-PET/CT zur Bildgebung des Prostatakarzinoms

    Energy Technology Data Exchange (ETDEWEB)

    Krause, Bernd Joachim [Klinik- und Poliklinik fuer Nuklearmedizin, Klinikum rechts der Isar, Technische Univ. Muenchen (Germany); Treiber, U.; Schwarzenboeck, S.; Souvatzoglou, M. [Klinik fuer Urologie, Klinikum rechts der Isar, Technische Univ. Muenchen (Germany)

    2010-09-15

    PET and PET/CT using [{sup 11}C]- and [{sup 18}F]-labelled choline derivatives are increasingly being used for imaging of prostate cancer. The value of PET and PET/CT with [{sup 11}C]- and [{sup 18}F]-labelled choline derivates in biochemical recurrence of prostate cancer has been examined in many studies and demonstrates an increasing importance. Primary prostate cancer can be detected with moderate sensitivity using PET and PET/CT using [{sup 11}C]- and [{sup 18}F]-labelled choline derivatives - the differentiation between benign prostatic hyperplasia, prostatitis or high-grade intraepithelial neoplasia (HGPIN) is not always possible. At the present time [{sup 11}C]choline PET/CT is not recommended in the primary setting but may be utilized in clinically suspected prostate cancer with repeatedly negative prostate biopsies, in preparation of a focused re-biopsy. Promising results have been obtained for the use of PET and PET/CT with [{sup 11}C]- and [{sup 18}F]-labelled choline derivates in patients with biochemical recurrence. The detection rate of choline PET and PET/CT for local, regional, and distant recurrence in patients with a biochemical recurrence shows a linear correlation with PSA values at the time of imaging and reaches about 75% in patients with PSA > 3 ng/mL. At PSA values below 1 ng/mL, the recurrence can be diagnosed with choline PET/CT in approximately 1/3 of the patients. PET and PET/CT with [{sup 11}C]- and [{sup 18}F]choline derivates can be helpful for choosing a therapeutic strategy in the sense of an individualized treatment: since an early diagnosis of recurrence is crucial to the choice of optimal treatment. The localization of the site of recurrence - local recurrence, lymph node metastasis or systemic dissemination - has important influence on the therapy regimen. (orig.)

  2. CT and MRI findings of a spinal arachnoid cyst

    International Nuclear Information System (INIS)

    Takahashi, Ryosuke; Kusaka, Hirofumi; Sadashima, Hiromichi

    1986-01-01

    A 39-year-old woman developed progressive difficulty in walking and urination over one year and 9 months. Her past history included a hystero-oophorectomy because of ''infection;'' the operation had been done under lumbar anesthesia. At the time of admission to our hospital, her legs were markedly spastic, with increased knee and ankle jerks as well as bilateral Babinski signs. Sensation to pain was slightly decreased bilaterally at and below Th4. Myelography through a suboccipital tap and CT myelography demonstrated a block of the CSF space at Th6. The spinal cord was displaced and became thin at and below Th1, secondary to an enlarged CSF space. Horizontal MRI demonstrated similar findings; however, sagittal MRI showed that the cord had been displaced and had collapsed; in addition, an abnormally enlarged CSF space indicated a subdural arachnoid cyst. MRI has thus been shown to be a very useful tool in the diagnosis of a spinal arachnoid cyst as well as other spinal-cord diseases. (author)

  3. Endobronchial metastasis: CT findings and its usefulness in bronchoscopic correlation

    International Nuclear Information System (INIS)

    Ko, Ji Ho; Jung, Gyoo Sik; Kim, Seong Min; Huh Jin Do; Joh, Young Duk; Jang, Tae Weon

    2000-01-01

    To evaluate the CT findings of bronchial abnormalities in patients with endobronchial metastasis from extrapulmonary tumors, and to correlate these with the bronchoscopic findings. The authors retrospectively reviewed the CT and bronchoscopic findings of 17 patients (M:F =3D 9:8; mean age, 56 years) with histologically proven endobronchial metastasis from extrapulmonary primary tumors. Carcinoma of the uterine cervix (n=3D5) was the most common primary site for endobronchial metastasis. CT findings of bronchial abnormalities with associated peribronchial and lung parenchymal lesions were analyzed and compared with the bronchoscopic findings. Among the 17 patients, 20 sites of bronchial abnormalities were visualized bronchoscopically. CT findings of bronchial abnormalities were smooth narrowing (n=3D11), occlusion (n=3D3), intraluminal mass (n=3D4), and normal (n=3D2). Peribronchial lesions (lymph node enlargement or parenchymal mass) were found in 12 cases. Bronchoscopy revealed bronchial narrowing due to a mucosal nodule or intraluminal polypoid mass in 16 cases, and total obstruction of the bronchus in four. With regard to the identification of bronchial abnormalities, the findings of CT and of bronchoscopy agreed in 17 cases and disagreed in three. While bronchoscopy was advantageous for detecting early mucosal abnormality, CT effectively evaluated the extent of a lesion beyond the stenosis or bronchial obstruction. CT was also useful for predicting the causes of bronchial abnormalities. CT is relatively accurate in evaluating bronchial abnormalities, and in patients with endobronchial metastases may be used as a complementary procedure to bronchoscopy for evaluating the extent of the lesion. (author)

  4. Site-matched assessment of structural and tissue properties of cortical bone using scanning acoustic microscopy and synchrotron radiation μCT

    International Nuclear Information System (INIS)

    Raum, K; Leguerney, I; Chandelier, F; Talmant, M; Saied, A; Peyrin, F; Laugier, P

    2006-01-01

    200 MHz scanning acoustic microscopy (SAM) and synchrotron radiation μCT (SR-μCT) were used to assess microstructural parameters and tissue properties in site-matched regions of interest in cortical bone. Anterior and postero-lateral regions of ten cross sections from human cortical radius were explored. Structural parameters, including diameter and number of Haversian canals per cortical area (Ca.Dm, N.Ca/Ar) and porosity Po were assessed with both methods using a custom-developed image fusion and analysis software. Acoustic impedance Z and degree of mineralization of bone DMB were extracted separately for osteonal and interstitial tissues from the fused images. Structural parameter estimations obtained from radiographic and acoustic images were almost identical. DMB and impedance values were in the range between 0.77 and 1.28 g cm -3 and 5.13 and 12.1 Mrayl, respectively. Interindividual and regional variations were observed, whereas the strongest difference was found between osteonal and interstitial tissues (Z: 7.2 ± 1.1 Mrayl versus 9.3 ± 1.0 Mrayl, DMB: 1.06 ± 0.07 g cm -3 versus 1.16 ± 0.05 g cm -3 , paired t-test, p 2 = 0.174, p -4 ) and for the pooled (osteonal and interstitial) data. The regression of the pooled osteonal and interstitial tissue data follows a second-order polynomial (R 2 = 0.39, p -4 ). Both modalities fulfil the requirement for a simultaneous evaluation of cortical bone microstructure and material properties at the tissue level. While SAM inspection is limited to the evaluation of carefully prepared sample surfaces, SR-μCT provides volumetric information on the tissue without substantial preparation requirements. However, SAM provides a quantitative estimate of elastic properties at the tissue level that cannot be captured by SR-μCT

  5. Engineering measures and risk assessment against fault displacement

    International Nuclear Information System (INIS)

    Narabayashi, Tadashi; Okamoto, Koji; Dodo, Takashi; Kamiya, Masanobu

    2017-01-01

    A special committee on 'assessment on fault activities and engineering risk' was established at the Japan Atomic Energy Society. With a participation of the Japan Society of Maintenology, a study group on nuclear safety regulations was established at the Japan Society of Maintenology, and this theme has been examined. Among the technics for evaluating the effects of fault displacement on nuclear facilities, the concept of application of the safety margin evaluation method is shown. By applying this method, it is possible to evaluate nuclear safety against fault displacement, and it is also possible to obtain risk information such as the conditions of facilities and safety functions (retention or loss) as well as the safety margin against core damage, including the event exceeding prediction. Thus, it is possible to verify the effectiveness of accident management and to make decisions for further countermeasures to reduce risk through using the obtained risk information. The countermeasures prepared for large scale damage can also be effectively utilized. It is necessary not only the fault displacement targeted in this paper, but also the results of risk assessment obtained by safety margin assessment etc. are reflected on the improvement of accident management at the site, education and training, and assumption of various events and desk training, and are linked to safety improvement. Efforts for encouraging these actions are also required. (A.O.)

  6. Displacement cascades in diatomic materials

    International Nuclear Information System (INIS)

    Parkin, D.M.; Coulter, C.A.

    1981-01-01

    A new function, the specified-projectile displacement function p/sub ijk/ (E), is introduced to describe displacement cascades in polyatomic materials. This function describes the specific collision events that produce displacements and hence adds new information not previously available. Calculations of p/sub ijk/ (E) for MgO, Al 2 O 3 and TaO are presented and discussed. Results show that the parameters that have the largest effect on displacement collision events are the PKA energy and the mass ratio of the atom types in the material. It is further shown that the microscopic nature of the displacement events changes over the entire recoil energy range relevant to fusion neutron spectra and that these changes are different in materials whose mass ratio is near one than in those where it is far from one

  7. CT findings suggesting anastomotic leak and predicting the recovery period following gastric surgery

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Tae Ho; Kim, Jung Hoon; Shin, Cheong-Il; Kim, Se Hyung; Han, Joon Koo; Choi, Byung Ihn [Seoul National University College of Medicine, Department of Radiology, Institute of Radiation Medicine, Jongno-gu, Seoul (Korea, Republic of)

    2015-07-15

    To assess diagnostic performance of routine CT for detecting anastomotic leak after gastric surgery, and analyse the relationship between recovery period and CT findings. We included 179 patients who underwent immediate CT and fluoroscopy after gastric surgery. Two reviewers retrospectively rated the possibility of leak on CT using a five-point scale focused on predefined CT findings. They also evaluated CT findings. Patients were categorised as: Group I, leak on fluoroscopy; Group II, possible leak on CT but negative on fluoroscopy; Group III, no leak. We analysed the relationship between recovery period and group. Area under the curve for detecting leak on CT was 0.886 in R1 and 0.668 in R2 with moderate agreement (k = 0.482). Statistically common CT findings for leak included discontinuity, large amount of air-fluid and wall thickening at anastomosis site (p < 0.05). Discontinuity at anastomosis site and a large air-fluid collection were independently associated with leak (p < 0.05). The recovery period including hospitalisation and postoperative fasting period was longer in Group I than Group II or III (p < 0.05). Group II showed a longer recovery period than Group III (p < 0.05). Postoperative routine CT was useful for predicting anastomotic leak using specific findings, and for predicting length of recovery period. (orig.)

  8. Radiation exposure in whole body CT screening.

    Science.gov (United States)

    Suresh, Pamidighantam; Ratnam, S V; Rao, K V J

    2011-04-01

    Using a technology that "takes a look" at people's insides and promises early warnings of cancer, cardiac disease, and other abnormalities, clinics and medical imaging facilities nationwide are touting a new service for health conscious people: "Whole body CT screening" this typically involves scanning the body from the chin to below the hips with a form of x-ray imaging that produces cross-sectional images. In USA direct-to-consumer marketing of whole body CT is occurring today in many metropolitan areas. Free standing CT screening centres are being sited in shopping malls and other high density public areas, and these centres are being advertised in the electronic and print media. In this context the present article discussed the pros and cons of having such centres in India with the advent of multislice CT leading to fast scan times.

  9. Lymphoscintigraphic sentinel node identification in patients with breast cancer: the role of SPECT-CT

    International Nuclear Information System (INIS)

    Lerman, H.; Metser, U.; Lievshitz, G.; Sperber, F.; Shneebaum, S.; Even-Sapir, E.

    2006-01-01

    Lymph node status is a major factor in determining the stage, appropriate therapy and outcome in patients with breast cancer. It is therefore of clinical importance to accurately identify all sentinel nodes (SNs) for each individual tumour before surgery. The purpose of this study was to assess the role of SPECT-CT lymphoscintigraphy in SN identification in patients with breast cancer. Lymphoscintigraphy comprising planar and SPECT-CT acquisition was performed in 157 consecutive patients with breast cancer (mean age 54.7±10.6, range 27-81 years) with a palpable mass (n=100), with a non-palpable mass (n=52) or post lumpectomy (n=5). Planar and SPECT-CT images were interpreted separately and the two imaging techniques were compared with respect to their ability to identify hot nodes. Planar imaging alone was negative for identification of hot nodes in 15% of the patients. SPECT-CT alone was negative in 10% and both techniques were negative in 9% of the patients. Forty-six of the total of 361 (13%) hot nodes identified by lymphoscintigraphy were detected only on SPECT-CT, including 21 nodes obscured by the scattered radiation from the injection site, nine adjacent nodes misinterpreted on planar images as a single node and 16 nodes which were missed on planar images and detected on SPECT data. SPECT-CT detected additional sites of drainage unexpected on planar images, including axillary (n=23 patients), internal mammary (n=5 patients), interpectoral (n=3 patients) and intramammary (n=2 patients) lymph node sites. Fourteen of the 329 (4%) hot lesions seen on planar images were false positive non-nodal sites of uptake that were accurately assessed by SPECT-CT and further validated by surgery. In a single patient, SPECT-CT was negative while planar images identified the SN. (orig.)

  10. Calculation of displacement and helium production at the Clinton P. Anderson Los Alamos Meson Physics Facility (LAMPF) irradiation facility

    International Nuclear Information System (INIS)

    Wechsler, M.S.; Davidson, D.R.; Greenwood, L.R.; Sommer, W.F.

    1984-01-01

    CT: Differential and total displacement and helium production rates are calculated for copper irradiated by spallation neutrons and 760 MeV protons at the Clinton P. Anderson Los Alamos Meson Physics Facility (LAMPF). The calculations are performed using the SPECTER and VNMTC computer codes, the latter being specially designed for spallation radiation damage calculations. For comparison, similar SPECTER calculations are also described for irradiation of copper in EBR-II and RTNS-II. The results indicate substantial contributions to the displacement and helium production rates due to neutrons in the high-energy tail (above 20 MeV) of the LAMPF spallation neutron spectrum. Still higher production rates are calculated for irradiations in the direct proton beam. These results will provide useful background information for research to be conducted at a new irradiation facility at LAMPF

  11. Origin of the lattice sites occupied by implanted Co in Si

    CERN Document Server

    Silva, Daniel; Wahl, Ulrich; Martins Correia, Joao; Da Costa Pereira, Lino Miguel; Amorim, Lígia; Castro Ribeiro Da Silva, Manuel; Esteves De Araujo, Araujo Joao Pedro

    2014-01-01

    We have investigated the lattice location of implanted 61Co in silicon. By means of emission channeling, three different lattice sites have been identified: ideal substitutional sites, displaced bond-centered sites and displaced tetrahedral interstitial sites. To assess the origin of the observed lattice sites we have compared our results to emission channeling studies on 59Fe and 65Ni and to Mössbauer spectroscopy experiments on 57Co, present in literature. The possible interpretation of several 57Co Mössbauer lines is discussed in the light of our new results on the 61Co lattice location. The conclusions are relevant for the microscopic understanding of some gettering techniques.

  12. Small bowel obstruction in children: usefulness of CT for diagnosis and localization

    International Nuclear Information System (INIS)

    Lee, Young Cheol; Kim, Young Tong; Bae, Won Kyung; Kim, Il Young

    2007-01-01

    To evaluate the usefulness of CT for the diagnosis of the cause and localization of small bowel obstruction. Out of a group of children who underwent a CT examination for a suspected small bowel obstruction, 19 patients with confirmed underlying disorders were identified and included in the study. Neonates and patients with duodenal obstruction were excluded from the study. The CT findings were analyzed for the location of obstruction site, abnormalities of the mesentery and mesenteric vessels, bowel wall thickening, closed loop obstruction, and strangulation. The obstruction site was divided into five parts. The preoperative CT diagnosis was compared with the final diagnosis. Causes of small bowel obstruction were intussusception (n = 6), appendiceal perforation (n = 4), transmesenteric internal hernia (n = 2), postoperative bands (n = 1), idiopathic multiple bands (n = 1), a foreign body (n = 1), a small bowel adenocarcinoma (n = 1), Meckel's diverticulitis (n = 1), tuberculous peritonitis (n = 1) and Salmonella enteritis with bowel perforation (n = 1). The CT findings showed mesenteric vascular prominence (n = 13), omental or mesenteric infiltration (n = 10), localized bowel wall thickening (n = 7) closed loops obstruction (n = 3) and strangulation (n = 1). The obstruction site was identified in all cases. The causes of obstruction could be diagnosed preoperatively in 14 cases, but a preoperative diagnosis was difficult in 5 cases. The causes of small bowel obstruction in children are variable, and CT is useful for evaluating the cause and localization of small bowel obstruction

  13. Small bowel obstruction in children: usefulness of CT for diagnosis and localization

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Young Cheol; Kim, Young Tong; Bae, Won Kyung; Kim, Il Young [Cheonan Hospital, Soonchunhyang University, Cheonan (Korea, Republic of)

    2007-12-15

    To evaluate the usefulness of CT for the diagnosis of the cause and localization of small bowel obstruction. Out of a group of children who underwent a CT examination for a suspected small bowel obstruction, 19 patients with confirmed underlying disorders were identified and included in the study. Neonates and patients with duodenal obstruction were excluded from the study. The CT findings were analyzed for the location of obstruction site, abnormalities of the mesentery and mesenteric vessels, bowel wall thickening, closed loop obstruction, and strangulation. The obstruction site was divided into five parts. The preoperative CT diagnosis was compared with the final diagnosis. Causes of small bowel obstruction were intussusception (n = 6), appendiceal perforation (n = 4), transmesenteric internal hernia (n = 2), postoperative bands (n = 1), idiopathic multiple bands (n = 1), a foreign body (n = 1), a small bowel adenocarcinoma (n = 1), Meckel's diverticulitis (n = 1), tuberculous peritonitis (n = 1) and Salmonella enteritis with bowel perforation (n = 1). The CT findings showed mesenteric vascular prominence (n = 13), omental or mesenteric infiltration (n = 10), localized bowel wall thickening (n = 7) closed loops obstruction (n = 3) and strangulation (n = 1). The obstruction site was identified in all cases. The causes of obstruction could be diagnosed preoperatively in 14 cases, but a preoperative diagnosis was difficult in 5 cases. The causes of small bowel obstruction in children are variable, and CT is useful for evaluating the cause and localization of small bowel obstruction.

  14. Standardized CT protocols and nomenclature: better, but not yet there

    Energy Technology Data Exchange (ETDEWEB)

    Singh, Sarabjeet; Kalra, Mannudeep K. [Harvard Medical School, Department of Radiology, Massachusetts General Hospital, Boston, MA (United States)

    2014-10-15

    Radiation dose associated with CT is an important safety concern in patient care, especially in children. Technical advancements in multidetector-row CT scanner technology offer several advantages for clinical applications; these advancements have considerably increased CT utilization and enhanced the complexity of CT scanning protocols. Furthermore there are several scan manufacturers spearheading these technical advancements, leading to different commercial names causing confusion among the users, especially at imaging sites with scanners from different vendors. Several scientific studies and the National Council on Radiation Protection and Measurements (NCRP) have shown variation in CT radiation doses for same body region and similar scanning protocols. Therefore there is a need for standardization of scanning protocols and nomenclature of scan parameters. The following material reviews the status and challenges in standardization of CT scanning and nomenclature. (orig.)

  15. Functional Mechanism of Lung Mosaic CT Attenuation: Assessment with Deep-Inspiration Breath-Hold Perfusion SPECT-CT Fusion Imaging and Non-Breath-Hold Technegas SPECT

    International Nuclear Information System (INIS)

    Suga, K.; Yasuhiko, K.; Iwanaga, H.; Tokuda, O.; Matsunaga, N.

    2009-01-01

    Background: The functional mechanism of lung mosaic computed tomography attenuation (MCA) in pulmonary vascular disease (PVD) and obstructive airway disease (OAD) has not yet been fully clarified. Purpose: To clarify the mechanism of MCA in these diseases by assessing the relationship between regional lung function and CT attenuation change at MCA sites with the use of automated deep-inspiratory breath-hold (DIBrH) perfusion single-photon emission computed tomography (SPECT)-CT fusion images and non-breath-hold Technegas SPECT. Material and Methods: Subjects were 42 PVD patients (31 pulmonary thromboembolism, four primary/two secondary pulmonary hypertension, and five Takayasu arteritis), 12 OAD patients (five acute asthma, four obliterative bronchiolitis, and three bronchiectasis), and 12 normal controls, all of whom had MCA on DIBrH CT. The relationship between regional lung function and CT attenuation change at the lung slices with MCA was assessed using DIBrH perfusion SPECT-CT fusion images and non-breath-hold Technegas SPECT. The severity of perfusion defects with or without MCA was quantified by regions-of-interest analysis. Results: On DIBrH CT and perfusion SPECT, in contrast to no noticeable CT attenuation abnormality and fairly uniform perfusion in controls, 60 MCA and 274 perfusion defects in PVD patients, and 18 MCA and 61 defects in OAD patients were identified, with a total of 77 ventilation defects on Technegas SPECT in all patients. SPECT-CT correlation showed that, throughout the 78 MCA sites of all patients, lung perfusion was persistently decreased at low CT attenuation and preserved at intervening high CT attenuation, while lung ventilation was poorly correlated with CT attenuation change. The radioactivity ratios of reduced perfusion and the intervening preserved perfusion at the 78 perfusion defects with MCA were significantly lower than those at the remaining 257 defects without MCA (P<0.0001). Conclusion: Although further validation is

  16. Functional Mechanism of Lung Mosaic CT Attenuation: Assessment with Deep-Inspiration Breath-Hold Perfusion SPECT-CT Fusion Imaging and Non-Breath-Hold Technegas SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Suga, K.; Yasuhiko, K. (Dept. of Radiology, St. Hill Hospital, Ube, Yamaguchi (Japan)); Iwanaga, H.; Tokuda, O.; Matsunaga, N. (Dept. of Radiology, Yamaguchi Univ. School of Medicine, Ube, Yamaguchi (Japan))

    2009-01-15

    Background: The functional mechanism of lung mosaic computed tomography attenuation (MCA) in pulmonary vascular disease (PVD) and obstructive airway disease (OAD) has not yet been fully clarified. Purpose: To clarify the mechanism of MCA in these diseases by assessing the relationship between regional lung function and CT attenuation change at MCA sites with the use of automated deep-inspiratory breath-hold (DIBrH) perfusion single-photon emission computed tomography (SPECT)-CT fusion images and non-breath-hold Technegas SPECT. Material and Methods: Subjects were 42 PVD patients (31 pulmonary thromboembolism, four primary/two secondary pulmonary hypertension, and five Takayasu arteritis), 12 OAD patients (five acute asthma, four obliterative bronchiolitis, and three bronchiectasis), and 12 normal controls, all of whom had MCA on DIBrH CT. The relationship between regional lung function and CT attenuation change at the lung slices with MCA was assessed using DIBrH perfusion SPECT-CT fusion images and non-breath-hold Technegas SPECT. The severity of perfusion defects with or without MCA was quantified by regions-of-interest analysis. Results: On DIBrH CT and perfusion SPECT, in contrast to no noticeable CT attenuation abnormality and fairly uniform perfusion in controls, 60 MCA and 274 perfusion defects in PVD patients, and 18 MCA and 61 defects in OAD patients were identified, with a total of 77 ventilation defects on Technegas SPECT in all patients. SPECT-CT correlation showed that, throughout the 78 MCA sites of all patients, lung perfusion was persistently decreased at low CT attenuation and preserved at intervening high CT attenuation, while lung ventilation was poorly correlated with CT attenuation change. The radioactivity ratios of reduced perfusion and the intervening preserved perfusion at the 78 perfusion defects with MCA were significantly lower than those at the remaining 257 defects without MCA (P<0.0001). Conclusion: Although further validation is

  17. Functional mechanism of lung mosaic CT attenuation: assessment with deep-inspiration breath-hold perfusion SPECT-CT fusion imaging and non-breath-hold Technegas SPECT.

    Science.gov (United States)

    Suga, K; Yasuhiko, K; Iwanaga, H; Tokuda, O; Matsunaga, N

    2009-01-01

    The functional mechanism of lung mosaic computed tomography attenuation (MCA) in pulmonary vascular disease (PVD) and obstructive airway disease (OAD) has not yet been fully clarified. To clarify the mechanism of MCA in these diseases by assessing the relationship between regional lung function and CT attenuation change at MCA sites with the use of automated deep-inspiratory breath-hold (DIBrH) perfusion single-photon emission computed tomography (SPECT)-CT fusion images and non-breath-hold Technegas SPECT. Subjects were 42 PVD patients (31 pulmonary thromboembolism, four primary/two secondary pulmonary hypertension, and five Takayasu arteritis), 12 OAD patients (five acute asthma, four obliterative bronchiolitis, and three bronchiectasis), and 12 normal controls, all of whom had MCA on DIBrH CT. The relationship between regional lung function and CT attenuation change at the lung slices with MCA was assessed using DIBrH perfusion SPECT-CT fusion images and non-breath-hold Technegas SPECT. The severity of perfusion defects with or without MCA was quantified by regions-of-interest analysis. On DIBrH CT and perfusion SPECT, in contrast to no noticeable CT attenuation abnormality and fairly uniform perfusion in controls, 60 MCA and 274 perfusion defects in PVD patients, and 18 MCA and 61 defects in OAD patients were identified, with a total of 77 ventilation defects on Technegas SPECT in all patients. SPECT-CT correlation showed that, throughout the 78 MCA sites of all patients, lung perfusion was persistently decreased at low CT attenuation and preserved at intervening high CT attenuation, while lung ventilation was poorly correlated with CT attenuation change. The radioactivity ratios of reduced perfusion and the intervening preserved perfusion at the 78 perfusion defects with MCA were significantly lower than those at the remaining 257 defects without MCA (P<0.0001). Although further validation is required, our results indicate that heterogeneous pulmonary arterial

  18. Abdominal aspergillosis: CT findings

    Energy Technology Data Exchange (ETDEWEB)

    Yeom, Suk Keu, E-mail: pagoda20@hanmail.net [Department of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, 388-1, Poongnap2-dong, Songpa-gu, Seoul, 138-736 (Korea, Republic of); Kim, Hye Jin, E-mail: kimhyejin@amc.seoul.kr [Department of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, 388-1, Poongnap2-dong, Songpa-gu, Seoul, 138-736 (Korea, Republic of); Byun, Jae Ho, E-mail: jhbyun@amc.seoul.kr [Department of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, 388-1, Poongnap2-dong, Songpa-gu, Seoul, 138-736 (Korea, Republic of); Kim, Ah Young, E-mail: aykim@amc.seoul.kr [Department of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, 388-1, Poongnap2-dong, Songpa-gu, Seoul, 138-736 (Korea, Republic of); Lee, Moon-Gyu, E-mail: mglee@amc.seoul.kr [Department of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, 388-1, Poongnap2-dong, Songpa-gu, Seoul, 138-736 (Korea, Republic of); Ha, Hyun Kwon, E-mail: hkha@amc.seoul.kr [Department of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, 388-1, Poongnap2-dong, Songpa-gu, Seoul, 138-736 (Korea, Republic of)

    2011-03-15

    Objective: In order to retrospectively evaluate the CT findings of abdominal aspergillosis in immunocompromised patients. Materials and methods: CT scans were reviewed with regard to the sites, number, morphologic appearance, attenuation, and the contrast enhancement patterns of the lesions in six patients (5 women, 1 man; mean age, 43.4 years; range, 23-59 years) with pathologically proved abdominal aspergillosis by two gastrointestinal radiologists in consensus. Medical records were also reviewed to determine each patient's clinical status and outcome. Results: All patients were immunocompromised state: 4 patients received immunosuppressive therapy for solid organ transplantation and 2 patients received chemotherapy for acute myeloid leukemia. Aspergillosis involved blood vessels (n = 3), liver (n = 2), spleen (n = 2), gastrointestinal tract (n = 2), native kidney (n = 1), transplanted kidney (n = 1), peritoneum (n = 1), and retroperitoneum (n = 1). CT demonstrated solid organ or bowel infarction or perforation secondary to vascular thrombosis or pseudoaneurysm, multiple low-attenuating lesions of solid organs presenting as abscesses, concentric bowel wall thickening mimicking typhlitis, or diffuse or nodular infiltration of the peritoneum and retroperitoneum. Conclusion: Familiarity with findings commonly presenting as angioinvasive features or abscesses on CT, may facilitate the diagnosis of rare and fatal abdominal aspergillosis.

  19. Modelling toehold-mediated RNA strand displacement.

    Science.gov (United States)

    Šulc, Petr; Ouldridge, Thomas E; Romano, Flavio; Doye, Jonathan P K; Louis, Ard A

    2015-03-10

    We study the thermodynamics and kinetics of an RNA toehold-mediated strand displacement reaction with a recently developed coarse-grained model of RNA. Strand displacement, during which a single strand displaces a different strand previously bound to a complementary substrate strand, is an essential mechanism in active nucleic acid nanotechnology and has also been hypothesized to occur in vivo. We study the rate of displacement reactions as a function of the length of the toehold and temperature and make two experimentally testable predictions: that the displacement is faster if the toehold is placed at the 5' end of the substrate; and that the displacement slows down with increasing temperature for longer toeholds. Copyright © 2015 Biophysical Society. Published by Elsevier Inc. All rights reserved.

  20. External fixation for displaced intra-articular fractures of the calcaneum.

    Science.gov (United States)

    Magnan, B; Bortolazzi, R; Marangon, A; Marino, M; Dall'Oca, C; Bartolozzi, P

    2006-11-01

    A minimally-invasive procedure using percutaneous reduction and external fixation can be carried out for Sanders' type II, III and IV fractures of the os calcis. We have treated 54 consecutive closed displaced fractures of the calcaneum involving the articular surface in 52 patients with the Orthofix Calcaneal Mini-Fixator. Patients were followed up for a mean of 49 months (27 to 94) and assessed clinically with the Maryland Foot Score and radiologically with radiographs and CT scans, evaluated according to the Score Analysis of Verona. The clinical results at follow-up were excellent or good in 49 cases (90.7%), fair in two (3.7%) and poor in three (5.6%). The mean pre-operative Böhler's angle was 6.98 degrees (5.95 degrees to 19.86 degrees), whereas after surgery the mean value was 21.94 degrees (12.58 degrees to 31.30 degrees) (p fair in three (5.6%) and poor in two (3.7%). Transient local osteoporosis was observed in ten patients (18.5%), superficial pin track infection in three (5.6%), and three patients (5.6%) showed thalamic displacement following unadvised early weight-bearing. The clinical results appear to be comparable with those obtainable with open reduction and internal fixation, with the advantages of reduced risk using a minimally-invasive technique.

  1. Recurrent hepatoblastoma with localization by PET-CT

    Energy Technology Data Exchange (ETDEWEB)

    Figarola, Maria S.; McQuiston, Samuel A. [University of South Alabama, Department of Radiology, Mobile, AL (United States); Wilson, Felicia [University of South Alabama, Pediatric Hematology-Oncology, Mobile, AL (United States); Powell, Randall [University of South Alabama, Surgery Department, Mobile, AL (United States)

    2005-12-01

    Hepatoblastoma is the most common primary liver tumor in children, accounting for 79% of pediatric liver malignancies in children younger than 15 years, with most cases reported before the age of 5 years. Localization of primary and recurrent disease is necessary for appropriate clinical decision-making and treatment. We present a case of recurrent hepatoblastoma heralded by rising alpha-fetoprotein levels. After unsuccessful localization by conventional CT and MRI, positron emission tomography CT imaging localized the sites of recurrence. (orig.)

  2. Usefulness and pitfalls of MAA SPECT/CT in identifying digestive extrahepatic uptake when planning liver radioembolization

    International Nuclear Information System (INIS)

    Lenoir, Laurence; Garin, Etienne; Edeline, Julien; Rolland, Yann; Pracht, Marc; Raoul, Jean-Luc; Ardisson, Valerie; Bourguet, Patrick; Clement, Bruno; Boucher, Eveline

    2012-01-01

    Identifying gastroduodenal uptake of 99m Tc-macroaggregated albumin (MAA), which is associated with an increased risk of ulcer disease, is a crucial part of the therapeutic management of patients undergoing radioembolization for liver tumours. Given this context, the use of MAA single photon emission computed tomography (SPECT)/CT may be essential, but the procedure has still not been thoroughly evaluated. The aim of this retrospective study was to determine the effectiveness of MAA SPECT/CT in identifying digestive extrahepatic uptake, while determining potential diagnostic pitfalls. Overall, 139 MAA SPECT/CT scans were performed on 103 patients with different hepatic tumour types. Patients were followed up for at least 6 months according to standard requirements. Digestive, or digestive-like, uptake other than free pertechnetate was identified in 5.7% of cases using planar imaging and in 36.6% of cases using SPECT/CT. Uptake sites identified by SPECT/CT included the gastroduodenal region (3.6%), gall bladder (12.2%), portal vein thrombosis (6.5%), hepatic artery (6.5%), coil embolization site (2.1%) as well as falciform artery (5.0%). For 2.1% of explorations, a coregistration error between SPECT and CT imaging could have led to a false diagnosis by erroneously attributing an uptake site to the stomach or gall bladder, when the uptake actually occurred in the liver. SPECT/CT is more efficacious than planar imaging in identifying digestive extrahepatic uptake sites, with extrahepatic uptake observed in one third of scans using the former procedure. However, more than half of the uptake sites in our study were vascular in nature, without therapeutic implications. The risk of coregistration errors must also be kept in mind. (orig.)

  3. Usefulness and pitfalls of MAA SPECT/CT in identifying digestive extrahepatic uptake when planning liver radioembolization

    Energy Technology Data Exchange (ETDEWEB)

    Lenoir, Laurence; Garin, Etienne [Comprehensive Cancer Institute Eugene Marquis, Department of Nuclear Medicine, CS 44229, Rennes (France); University of Rennes 1, Rennes (France); Liver Metabolisms and Cancer, INSERM, U-991, Rennes (France); Edeline, Julien [University of Rennes 1, Rennes (France); Comprehensive Cancer Institute Eugene Marquis, Department of Medical Oncology, CS 44229, Rennes (France); Rolland, Yann [Comprehensive Cancer Institute Eugene Marquis, Department of Medical Imaging, CS 44229, Rennes (France); Pracht, Marc [Comprehensive Cancer Institute Eugene Marquis, Department of Medical Oncology, CS 44229, Rennes (France); Raoul, Jean-Luc [Comprehensive Cancer Institute Paoli Calmette, Department of Medical Oncology, Marseille (France); Ardisson, Valerie [Comprehensive Cancer Institute Eugene Marquis, Department of Nuclear Medicine, CS 44229, Rennes (France); Bourguet, Patrick [Comprehensive Cancer Institute Eugene Marquis, Department of Nuclear Medicine, CS 44229, Rennes (France); University of Rennes 1, Rennes (France); Clement, Bruno [Liver Metabolisms and Cancer, INSERM, U-991, Rennes (France); Boucher, Eveline [Liver Metabolisms and Cancer, INSERM, U-991, Rennes (France); Comprehensive Cancer Institute Eugene Marquis, Department of Medical Oncology, CS 44229, Rennes (France)

    2012-05-15

    Identifying gastroduodenal uptake of {sup 99m}Tc-macroaggregated albumin (MAA), which is associated with an increased risk of ulcer disease, is a crucial part of the therapeutic management of patients undergoing radioembolization for liver tumours. Given this context, the use of MAA single photon emission computed tomography (SPECT)/CT may be essential, but the procedure has still not been thoroughly evaluated. The aim of this retrospective study was to determine the effectiveness of MAA SPECT/CT in identifying digestive extrahepatic uptake, while determining potential diagnostic pitfalls. Overall, 139 MAA SPECT/CT scans were performed on 103 patients with different hepatic tumour types. Patients were followed up for at least 6 months according to standard requirements. Digestive, or digestive-like, uptake other than free pertechnetate was identified in 5.7% of cases using planar imaging and in 36.6% of cases using SPECT/CT. Uptake sites identified by SPECT/CT included the gastroduodenal region (3.6%), gall bladder (12.2%), portal vein thrombosis (6.5%), hepatic artery (6.5%), coil embolization site (2.1%) as well as falciform artery (5.0%). For 2.1% of explorations, a coregistration error between SPECT and CT imaging could have led to a false diagnosis by erroneously attributing an uptake site to the stomach or gall bladder, when the uptake actually occurred in the liver. SPECT/CT is more efficacious than planar imaging in identifying digestive extrahepatic uptake sites, with extrahepatic uptake observed in one third of scans using the former procedure. However, more than half of the uptake sites in our study were vascular in nature, without therapeutic implications. The risk of coregistration errors must also be kept in mind. (orig.)

  4. MRI of displaced meniscal fragments

    International Nuclear Information System (INIS)

    Dunoski, Brian; Zbojniewicz, Andrew M.; Laor, Tal

    2012-01-01

    A torn meniscus frequently requires surgical fixation or debridement as definitive treatment. Meniscal tears with associated fragment displacement, such as bucket handle and flap tears, can be difficult to recognize and accurately describe on MRI, and displaced fragments can be challenging to identify at surgery. A displaced meniscal fragment can be obscured by synovium or be in a location not usually evaluated at arthroscopy. We present a pictorial essay of meniscal tears with displaced fragments in patients referred to a pediatric hospital in order to increase recognition and accurate interpretation by the radiologist, who in turn can help assist the surgeon in planning appropriate therapy. (orig.)

  5. MRI of displaced meniscal fragments

    Energy Technology Data Exchange (ETDEWEB)

    Dunoski, Brian [University of Cincinnati College of Medicine, Department of Radiology, Cincinnati Children' s Hospital Medical Center, Cincinnati, OH (United States); Children' s Hospital of Michigan, Department of Radiology, Detroit, MI (United States); Zbojniewicz, Andrew M.; Laor, Tal [University of Cincinnati College of Medicine, Department of Radiology, Cincinnati Children' s Hospital Medical Center, Cincinnati, OH (United States)

    2012-01-15

    A torn meniscus frequently requires surgical fixation or debridement as definitive treatment. Meniscal tears with associated fragment displacement, such as bucket handle and flap tears, can be difficult to recognize and accurately describe on MRI, and displaced fragments can be challenging to identify at surgery. A displaced meniscal fragment can be obscured by synovium or be in a location not usually evaluated at arthroscopy. We present a pictorial essay of meniscal tears with displaced fragments in patients referred to a pediatric hospital in order to increase recognition and accurate interpretation by the radiologist, who in turn can help assist the surgeon in planning appropriate therapy. (orig.)

  6. Effects of threshold displacement energy on defect production by displacement cascades in α, β and γ-LiAlO2

    International Nuclear Information System (INIS)

    Tsuchihira, H.; Oda, T.; Tanaka, S.

    2013-01-01

    Threshold displacement energy evaluation and a series of displacement cascade simulations in α, β, and γ-LiAlO 2 were performed using molecular dynamics. Threshold displacement energy evaluations indicated that higher absolute ionic charge values and larger densities both increase threshold displacement energy. The displacement cascade simulations suggest that the influence of different crystal structures on the number of interstitial atoms generated in a displacement cascade is explainable almost entirely by the difference of the threshold displacement energy

  7. FDG PET/CT imaging in the diagnosis of osteomyelitis in the diabetic foot

    Energy Technology Data Exchange (ETDEWEB)

    Kagna, Olga; Keidar, Zohar [Rambam Health Care Campus, Department of Nuclear Medicine, POB 9602, Haifa (Israel); Srour, Saher; Militianu, Daniela [Rambam Health Care Campus, Department of Diagnostic Imaging, Haifa (Israel); Melamed, Eyal [Rambam Health Care Campus, Department of Orthopedics, Haifa (Israel)

    2012-10-15

    Osteomyelitis, the most serious complication of the diabetic foot, occurs in about 20 % of patients. Early diagnosis is crucial. Appropriate treatment will avoid or decrease the likelihood of amputation. The objective of this study was to assess the value of FDG PET/CT in diabetic patients with clinically suspected osteomyelitis. Enrolled in this prospective study were 39 consecutive diabetic patients (29 men and 10 women, mean age 57 years, range 28-71 years) with 46 suspected sites of foot infection. Of these 39 patients, 38 had type 2 and 1 type 1 diabetes for 4-25 years, and 28 were receiving treatment with insulin. FDG PET/CT was interpreted for the presence, intensity (SUVmax) and localization of increased FDG foci. Final diagnosis was based on histopathology and bacteriology of surgical samples, or clinical and imaging follow-up. Osteomyelitis was correctly diagnosed in 18 and excluded in 21 sites. Of 20 lesions with focal bone FDG uptake, 2 were false-positive with no further evidence of osteomyelitis. Five sites of diffuse FDG uptake involving more than one bone on CT were correctly diagnosed as diabetic osteoarthropathy. FDG PET/CT had a sensitivity, specificity and accuracy of 100 %, 92 % and 95 % in a patient-based analysis and 100 %, 93 % and 96 % in a lesion-based analysis, respectively, for the diagnosis of osteomyelitis in the diabetic foot. FDG PET/CT was found to have high performance indices for evaluation of the diabetic foot. The PET component identified FDG-avid foci in sites of acute infection which were precisely localized on fused PET/CT images allowing correct differentiation between osteomyelitis and soft-tissue infection. (orig.)

  8. FDG PET/CT imaging in the diagnosis of osteomyelitis in the diabetic foot

    International Nuclear Information System (INIS)

    Kagna, Olga; Keidar, Zohar; Srour, Saher; Militianu, Daniela; Melamed, Eyal

    2012-01-01

    Osteomyelitis, the most serious complication of the diabetic foot, occurs in about 20 % of patients. Early diagnosis is crucial. Appropriate treatment will avoid or decrease the likelihood of amputation. The objective of this study was to assess the value of FDG PET/CT in diabetic patients with clinically suspected osteomyelitis. Enrolled in this prospective study were 39 consecutive diabetic patients (29 men and 10 women, mean age 57 years, range 28-71 years) with 46 suspected sites of foot infection. Of these 39 patients, 38 had type 2 and 1 type 1 diabetes for 4-25 years, and 28 were receiving treatment with insulin. FDG PET/CT was interpreted for the presence, intensity (SUVmax) and localization of increased FDG foci. Final diagnosis was based on histopathology and bacteriology of surgical samples, or clinical and imaging follow-up. Osteomyelitis was correctly diagnosed in 18 and excluded in 21 sites. Of 20 lesions with focal bone FDG uptake, 2 were false-positive with no further evidence of osteomyelitis. Five sites of diffuse FDG uptake involving more than one bone on CT were correctly diagnosed as diabetic osteoarthropathy. FDG PET/CT had a sensitivity, specificity and accuracy of 100 %, 92 % and 95 % in a patient-based analysis and 100 %, 93 % and 96 % in a lesion-based analysis, respectively, for the diagnosis of osteomyelitis in the diabetic foot. FDG PET/CT was found to have high performance indices for evaluation of the diabetic foot. The PET component identified FDG-avid foci in sites of acute infection which were precisely localized on fused PET/CT images allowing correct differentiation between osteomyelitis and soft-tissue infection. (orig.)

  9. CT diagnosis and differential diagnosis of the masses in lateral district of neck

    International Nuclear Information System (INIS)

    Cai Wenchong; Wei Zengcai; Li Huajie

    2006-01-01

    Objective: To analyze the CT findings and the corresponding anatomic basis of the masses arising in the lateral district of neck, and improve the diagnosis. Methods: CT findings in 52 patients with tumours in lateral district of neck, pathologically proved, were retrospectively studied on the size of the masses, morphology, density, margin, contrast enhanced characteristics, location and relationship with adjacent vessels and spaces. Results: Among the 52 cases, masses were located in the prestyloid space in 8 cases, in the parotid in 8, within the masticator space in 2, and in the carotid space in 31. In most of the cases, CT revealed the pathologic nature of the masses and adjacent anatomic structure. According to the displacement of the adjacent spaces muscles and vessels caused by the masses, the origin of the masses could be predicted. The origin of the masses was spatially related to the internal carotid artery and the jugular vein. Conclusion: CT is an effective modality for the positional diagnosis of the masses arising lateral district of neck. Considering the anatomical position and contrast enhanced characteristics and the involvement of the adjacent structure, the qualitative and differential diagnosis can be improved. (authors)

  10. Structure and interaction of silk fibroin and graphene oxide in concentrated solution under shear.

    Science.gov (United States)

    Zhang, Chao; Shao, Huili; Luo, Jie; Hu, Xuechao; Zhang, Yaopeng

    2018-02-01

    Considering the high biocompatibility of regenerated silk fibroin (RSF) and the good enhancement effect of graphene oxide (GO), various RSF/GO composite materials have been previously investigated, and found that GO plays a vital role in the fabrication of high-performance RSF/GO materials. However, its effects on the structure of RSF solution are unclear. Therefore, in this work, we studied the rheological and optical properties, as well as the aggregation behavior of concentrated RSF/GO solution in response to applied shear. The results demonstrated that the presence of GO sheets in RSF solution increased the shear resistance, while delayed the sol-gel transition. Moreover, GO sheets were not favorable to the formation of the ordered structures of RSF. The results from small angle X-ray scattering (SAXS) of RSF/GO solution also showed that the shear process promoted the formation of RSF/GO interface. The data also provided insights into the structural evolution within the mixture solutions, which can be beneficial to the future design and fabrication of nanofiller-reinforced high-performance materials. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Quantitative analysis of the patellofemoral motion pattern using semi-automatic processing of 4D CT data.

    Science.gov (United States)

    Forsberg, Daniel; Lindblom, Maria; Quick, Petter; Gauffin, Håkan

    2016-09-01

    To present a semi-automatic method with minimal user interaction for quantitative analysis of the patellofemoral motion pattern. 4D CT data capturing the patellofemoral motion pattern of a continuous flexion and extension were collected for five patients prone to patellar luxation both pre- and post-surgically. For the proposed method, an observer would place landmarks in a single 3D volume, which then are automatically propagated to the other volumes in a time sequence. From the landmarks in each volume, the measures patellar displacement, patellar tilt and angle between femur and tibia were computed. Evaluation of the observer variability showed the proposed semi-automatic method to be favorable over a fully manual counterpart, with an observer variability of approximately 1.5[Formula: see text] for the angle between femur and tibia, 1.5 mm for the patellar displacement, and 4.0[Formula: see text]-5.0[Formula: see text] for the patellar tilt. The proposed method showed that surgery reduced the patellar displacement and tilt at maximum extension with approximately 10-15 mm and 15[Formula: see text]-20[Formula: see text] for three patients but with less evident differences for two of the patients. A semi-automatic method suitable for quantification of the patellofemoral motion pattern as captured by 4D CT data has been presented. Its observer variability is on par with that of other methods but with the distinct advantage to support continuous motions during the image acquisition.

  12. Detection ability of FDG-PET/CT comparing with other imaging modalities in multiple myeloma patients

    International Nuclear Information System (INIS)

    Chae, Min Jeong; Lee, Tae Hyun; Pai, Moon Sun; Cheon, Gi Jeong; Choi, Chang Woon; Lim, Sang Moo

    2007-01-01

    Multiple myeloma (MM) is characterized by bone marrow infiltration with malignant plasma cells. It is important to detect involving bone for diagnosis and management of MM. The aim of this study was to evaluate the diagnostic ability and limitation of 18F-FDG-PET/CT (PET/CT) comparing other imaging modalities (separated PET and CT, whole body plain X-ray (XR), bone scintigraphy (BS), and MRI) in MM. Twenty PET/CT scans were performed in 16 patients (M: F=6: 10, median age=59 y). PET/CT findings were compared with available other images (n of CT=21, XR=21, BS=8, and MRI=5). Concordance with more than 2 image modalities, laboratory data, symptom, and biopsies were used for diagnosis of detected lesions. PET/CT revealed 256 of total 287 sites (sensitivity, 89.2%; accuracy, 84.8%). The sensitivity and accuracy of separating PET, CT, and XR were 86.3%, 70.4%; 47.4%, 50.3%; and 72.8%, 72.4%, respectively. Available BS identified 67 of 202 sites (sensitivity, 33.2%; accuracy, 44.0%). MRI detected 20 of 24 sites (sensitivity, 83.3%; accuracy, 36.3%). False positive rate (FP) of PET, XR, and MRI was as high as 87.8%, 95.1%, and 100%. PET for rib lesion identified 9 of 10 patients (90.0%) but for skull lesion only 4 of 7 patients (57.2%) with underestimation. 5 patients in MRI showed diffuse marrow signal change but only 3 had marrow involvement. But PET/CT showed higher accuracy than MRI. PET/CT was the most useful tool for detecting involving bone of MM comparing with other imaging modalities. Moreover, PET/CT is expected to overcome the limitations for the small osteolytic bone lesions with diffuse FDG uptake on PET

  13. CT evaluation of complications of cryoablation treatment in lung cancer

    International Nuclear Information System (INIS)

    Zhu Caiqiao; Chen Yao; Zhang Zhitian; Su Jinzhan; Huang Zhen; Bao Kaikai

    2011-01-01

    Objective: To assess the complications of percutaneous targeted Argon-Helium cryoablation treatment in patients with lung cancer on CT. Methods: Ten patients with unresectable lung cancer were treated by cryotherapy under CT guidance with Argon-Helium cryoablation system. Dynamic contrast-enhanced CT was performed to assess changes before and after treatment, complications and treatment response. Results: Ice ball coverage immediately after surgery was satisfactory in all patients. There were a few complications including worsening hoarseness (1), small pneumothorax (1), and small amount of bleeding at the site of probe puncture (1). Conclusion: Percutaneous targeted Argon-Helium cryoablation guided by CT is an effective treatment for lung cancer without severe complications. (authors)

  14. Role of FDG PET/CT in Baastrup's disease

    International Nuclear Information System (INIS)

    Subramanyam, Padma; Palaniswamy, Shanmuga Sundaram

    2016-01-01

    Baastrup's disease is a benign condition, which presents as chronic low back pain. It is also known as “kissing spine syndrome” and refers to close approximation of adjacent spinous processes producing inflammation and back pain. This condition is often misdiagnosed, resulting in incorrect treatment and persistence of symptoms. Diagnosis of Baastrup's disease is verified with clinical examination and imaging studies. Conventionally, clinicians resort to magnetic resonance imaging (MRI) of spine rather than X-ray or computed tomography (CT) in the evaluation of back pain. MRI can additionally identify flattening, sclerosis, enlargement, cystic lesions, and bone edema at the articulating surfaces of the two affected spinous processes. Studies have reported that 18 Fluorine fluorodeoxyglucose-positron emission tomography/CT (FDG-PET/CT) can detect a bursitis or an inflammation as a form of stress reaction despite a negative MRI and 99m Tc Methylene diphosphonate (MDP) bone scan. PET/CT is usually not a recommended investigation for this condition. However, this case report highlights the benefit of FDG-PET/CT in identifying the site of inflammatory pathology. It is also known to identify the exact site of inflammation where steroid or local anesthetic injection can be administered to alleviate pain, especially in patients with multilevel vertebral involvement

  15. Surgical treatment on displaced and dislocated sagittal fractures of the mandibular condyle.

    Science.gov (United States)

    Jing, Jie; Han, Yu; Song, Yu; Wan, Yingbiao

    2011-06-01

    The purpose of this study was to evaluate the effect of surgical treatment on displaced and dislocated sagittal fractures of the mandibular condyle (SFMC). Twenty-four patients with 28 displaced and dislocated SFMCs were distinguished into type M, type C, and type L fractures according the location of the fracture line. The fractured fragment was reduced and fixated with two 0.6-mm 4-hole micro-plates via a preauricular temporal incision. The fragment was extirpated when it was too small to be fixated. The postoperative position and profile of the fragment was examined by orthopantomogram radiograph or computed tomography (CT). The function of the temporal and zygomatic branches of the facial nerve was inspected. The occluding relation was surveyed, the interincisal distance at maximum mouth opening was measured, and the deviation from the midline during mouth opening was recorded. Twenty-three condyles (82%) suffered dislocated fractures with the condylar fragment out of the glenoid fossa. Five condyles (18%) were displaced, but not dislocated. There were 2 (7%) type M, 19 (68%) type C (3 comminuted), and 7 (25%) type L fractures (1 comminuted), respectively. Twenty-one (75%) fractured fragments received free-graft procedures with 2 micro-plates. Four (14%) fragments were reduced and fixated without being dissected free of their attachments. Three (11%) fragments were extirpated. There were no permanent facial never branch injuries. Micro-plate removal was necessary because of postoperative infection and necrosis of the fractured fragment in 1 condylar process. No other patients could be found with obvious postoperative bone resorption. The average postoperative maximum mouth opening and deviation at 6 months were improved significantly. The postoperative occlusion was good in 22 cases. Access with the preauricular incision, and the dislocated and displaced fragment can be reduced and fixated to its normal position easily. Free-graft procedure is a suitable

  16. The area postrema (AP) and the parabrachial nucleus (PBN) are important sites for salmon calcitonin (sCT) to decrease evoked phasic dopamine release in the nucleus accumbens (NAc).

    Science.gov (United States)

    Whiting, Lynda; McCutcheon, James E; Boyle, Christina N; Roitman, Mitchell F; Lutz, Thomas A

    2017-07-01

    The pancreatic hormone amylin and its agonist salmon calcitonin (sCT) act via the area postrema (AP) and the lateral parabrachial nucleus (PBN) to reduce food intake. Investigations of amylin and sCT signaling in the ventral tegmental area (VTA) and nucleus accumbens (NAc) suggest that the eating inhibitory effect of amylin is, in part, mediated through the mesolimbic 'reward' pathway. Indeed, administration of the sCT directly to the VTA decreased phasic dopamine release (DA) in the NAc. However, it is not known if peripheral amylin modulates the mesolimbic system directly or whether this occurs via the AP and PBN. To determine whether and how peripheral amylin or sCT affect mesolimbic reward circuitry we utilized fast scan cyclic voltammetry under anesthesia to measure phasic DA release in the NAc evoked by electrical stimulation of the VTA in intact, AP lesioned and bilaterally PBN lesioned rats. Amylin (50μg/kg i.p.) did not change phasic DA responses compared to saline control rats. However, sCT (50μg/kg i.p.) decreased evoked DA release to VTA-stimulation over 1h compared to saline treated control rats. Further investigations determined that AP and bilateral PBN lesions abolished the ability of sCT to suppress evoked phasic DA responses to VTA-stimulation. These findings implicate the AP and the PBN as important sites for peripheral sCT to decrease evoked DA release in the NAc and suggest that these nuclei may influence hedonic and motivational processes to modulate food intake. Copyright © 2017 Elsevier Inc. All rights reserved.

  17. CT features of abdominal plasma cell neoplasms

    International Nuclear Information System (INIS)

    Monill, J.; Pernas, J.; Montserrat, E.; Perez, C.; Clavero, J.; Martinez-Noguera, A.; Guerrero, R.; Torrubia, S.

    2005-01-01

    The aim of this study was to describe the CT features of abdominal plasma cell neoplasms. We reviewed CT imaging findings in 11 patients (seven men, four women; mean age 62 years) with plasma cell neoplasms and abdominal involvement. Helical CT of the entire abdomen and pelvis was performed following intravenous administration of contrast material. Images were analyzed in consensus by two radiologists. Diagnoses were made from biopsy, surgery and/or clinical follow-up findings. Multiple myeloma was found in seven patients and extramedullary plasmacytoma in four patients. All patients with multiple myeloma had multifocal disease with involvement of perirenal space (4/7), retroperitoneal and pelvic lymph nodes (3/7), peritoneum (3/7), liver (2/7), subcutaneous tissues (2/7) and kidney (1/7). In three of the four patients with extramedullary plasmacytoma, a single site was involved, namely stomach, vagina and retroperitoneum. In the fourth patient, a double site of abdominal involvement was observed with rectal and jejunal masses. Plasma cell neoplasm should be considered in the differential diagnosis of single or multiple enhancing masses in the abdomen or pelvis. Abdominal plasma cell neoplasms were most frequently seen as well-defined enhancing masses (10/11). (orig.)

  18. Detection of Cancer with PET and PET/CT in Asymptomatic Volunteers

    International Nuclear Information System (INIS)

    Chung, Ji In; Choi, Joon Young; Lee, Kyung Han; Kim, Byung Tae; Choi, Yoon Ho; Cho, Han Byoul; Shim, Jae Yong

    2009-01-01

    We retrospectively investigated the diagnostic performance of 18 F-fluorodeoxyglucose positron emission tomography (PET) and PET/CT for cancer detection in asymptomatic health-check examinees. This study consisted of 5091 PET or PET/CT conducted as part of annual health examination at one hospital from March 1998 to February 2008. To find the incidence of cancers, medical records of the subjects were thoroughly reviewed for a follow-up period of one year. The patterns of formal readings of PET and PET/CT were analyzed to assess the sensitivity and specificity for cancer detection. The histopathology and stage of the cancers were evaluated in relation to the results of PET. Eighty-six cancers (1.7%) were diagnosed within one year after PET or PET/CT. When PET and PET/CT results were combined, the sensitivity was 48.8% and specificity was 81.1% for cancer detection. PET only had a sensitivity of 46.2% and a specificity of 81.4%, and PET/CT only had a sensitivity of 75.0% and a specificity of 78.5% respectively. There were no significant differences in cancer site, stage and histopathology between PET positive and PET negative cancers. In 19.3% of formal readings of PET and PET/CT, further evaluation to exclude malignancy or significant disease was recommended. Head and neck area and upper gastrointestinal tract were commonly recommended sites for further evaluation. PET and PET/CT showed moderate performance for detecting cancers in asymptomatic adults in this study. More experience and further investigation are needed to overcome limitations of PET and PET/CT for cancer screening

  19. Initial staging of Hodgkin's disease: role of contrast-enhanced 18F FDG PET/CT.

    Science.gov (United States)

    Chiaravalloti, Agostino; Danieli, Roberta; Caracciolo, Cristiana Ragano; Travascio, Laura; Cantonetti, Maria; Gallamini, Andrea; Guazzaroni, Manlio; Orlacchio, Antonio; Simonetti, Giovanni; Schillaci, Orazio

    2014-08-01

    The objective of this study was to compare the diagnostic accuracy of positron emission tomography/low-dose computed tomography (PET/ldCT) versus the same technique implemented by contrast-enhanced computed tomography (ceCT) in staging Hodgkin's disease (HD).Forty patients (18 men and 22 women, mean age 30 ± 9.6) with biopsy-proven HD underwent a PET/ldCT study for initial staging including an unenhanced low-dose computed tomography for attenuation correction with positron emission tomography acquisition and a ceCT, performed at the end of the PET/ldCT scan, in the same exam session. A detailed datasheet was generated for illness locations for separate imaging modality comparison and then merged in order to compare the separate imaging method results (PET/ldCT and ceCT) versus merged results positron emission tomography/contrast-enhanced computed tomography (PET/ceCT). The nodal and extranodal lesions detected by each technique were then compared with follow-up data that served as the reference standard.No significant differences were found at staging between PET/ldCT and PET/ceCT in our series. One hundred and eighty four stations of nodal involvement have been found with no differences in both modalities. Extranodal involvement was identified in 26 sites by PET/ldCT and in 28 by PET/ceCT. We did not find significant differences concerning the stage (Ann Arbor).Our study shows a good concordance and conjunction between PET/ldCT and ceCT in both nodal and extranodal sites in the initial staging of HD, suggesting that PET/ldCT could suffice in most of these patients.

  20. Characterizing bone marrow involvement in Hodgkin's lymphoma by FDG-PET/CT

    International Nuclear Information System (INIS)

    Weiler-Sagie, Michal; Kagna, Olga; Dann, Eldad J.; Ben-Barak, Ayelet; Israel, Ora

    2014-01-01

    Fluoro-deoxyglucose positron emission tomography combined with computed tomography (FDG-PET/CT) is superior to iliac bone marrow biopsy (iBMB) for detection of bone marrow involvement (BMI) in staging of Hodgkin's lymphoma (HL). The present study aims to characterize the patterns and distribution of BMI in HL as determined by FDG-PET/CT. Reports of FDG-PET/CT studies performed for staging of HL were reviewed. BMI was defined as positive iBMB and/or foci of pathological FDG uptake in the skeleton that behaved in concordance with other sites of lymphoma in studies following chemotherapy. Number of FDG uptake foci, their specific location in the skeleton and the presence of corresponding lesions in the CT component of the study, and stage according to the Ann Arbor staging system, were recorded. The study included 473 patients. iBMB was performed in 336 patients. Nine patients had positive iBMB (9/336, 3 %). Seventy-three patients (73/473, 15 %) had FDG-PET/CT-defined BMI. The BM was the only extranodal site of HL in 52/473 patients (11 %). Forty-five patients had three or more foci of pathological skeletal FDG uptake (45/73, 62 %). Sixty-four patients (64/73, 88 %) had at least one uptake focus in the pelvis or vertebrae. In 60 patients (60/73, 82 %), the number of skeletal FDG uptake foci without corresponding CT lesions was equal to or higher than the number of foci with morphological abnormalities. FDG-PET/CT demonstrated BMI in 15 % of patients with newly diagnosed HL. Diagnosis of BMI in HL by FDG-PET/CT was more sensitive than iBMB with potential upstage in 11 % of patients. The most common pattern of FDG-PET/CT BMI was multifocal (at least three foci) skeletal FDG uptake, with at least one focus in the pelvis or vertebrae and no corresponding CT lesions. (orig.)

  1. Sensitivity of Induced Seismic Sequences to Rate-and-State Frictional Processes

    Science.gov (United States)

    Kroll, Kayla A.; Richards-Dinger, Keith B.; Dieterich, James H.

    2017-12-01

    It is well established that subsurface injection of fluids increases pore fluid pressures that may lead to shear failure along a preexisting fault surface. Concern among oil and gas, geothermal, and carbon storage operators has risen dramatically over the past decade due to the increase in the number and magnitude of induced earthquakes. Efforts to mitigate the risk associated with injection-induced earthquakes include modeling of the interaction between fluids and earthquake faults. Here we investigate this relationship with simulations that couple a geomechanical reservoir model and RSQSim, a physics-based earthquake simulator. RSQSim employs rate- and state-dependent friction (RSF) that enables the investigation of the time-dependent nature of earthquake sequences. We explore the effect of two RSF parameters and normal stress on the spatiotemporal characteristics of injection-induced seismicity. We perform >200 simulations to systematically investigate the effect of these model components on the evolution of induced seismicity sequences and compare the spatiotemporal characteristics of our synthetic catalogs to observations of induced earthquakes. We find that the RSF parameters control the ability of seismicity to migrate away from the injection well, the total number and maximum magnitude of induced events. Additionally, the RSF parameters control the occurrence/absence of premonitory events. Lastly, we find that earthquake stress drops can be modulated by the normal stress and/or the RSF parameters. Insight gained from this study can aid in further development of models that address best practice protocols for injection operations, site-specific models of injection-induced earthquakes, and probabilistic hazard and risk assessments.

  2. Fundamentals of displacement production in irradiated metals

    International Nuclear Information System (INIS)

    Doran, D.G.

    1975-09-01

    Radioinduced displacement damage in metals is described. Discussions are included on the displacement event itself, calculation of displacement rates in general, the manner in which different types of radiation interact with metals to produce displacements, the similarities and differences in the types of damage produced, the current status of computer simulations of displacement cascades, experimental evidence regarding cascades, and aspects of correlating damage produced by different types of radiation

  3. [18F]fluoroethylcholine-PET/CT imaging for radiation treatment planning of recurrent and primary prostate cancer with dose escalation to PET/CT-positive lymph nodes

    Directory of Open Access Journals (Sweden)

    Wahl Andreas

    2011-05-01

    Full Text Available Abstract Background At present there is no consensus on irradiation treatment volumes for intermediate to high-risk primary cancers or recurrent disease. Conventional imaging modalities, such as CT, MRI and transrectal ultrasound, are considered suboptimal for treatment decisions. Choline-PET/CT might be considered as the imaging modality in radiooncology to select and delineate clinical target volumes extending the prostate gland or prostate fossa. In conjunction with intensity modulated radiotherapy (IMRT and imaged guided radiotherapy (IGRT, it might offer the opportunity of dose escalation to selected sites while avoiding unnecessary irradiation of healthy tissues. Methods Twenty-six patients with primary (n = 7 or recurrent (n = 19 prostate cancer received Choline-PET/CT planned 3D conformal or intensity modulated radiotherapy. The median age of the patients was 65 yrs (range 45 to 78 yrs. PET/CT-scans with F18-fluoroethylcholine (FEC were performed on a combined PET/CT-scanner equipped for radiation therapy planning. The majority of patients had intermediate to high risk prostate cancer. All patients received 3D conformal or intensity modulated and imaged guided radiotherapy with megavoltage cone beam CT. The median dose to primary tumours was 75.6 Gy and to FEC-positive recurrent lymph nodal sites 66,6 Gy. The median follow-up time was 28.8 months. Results The mean SUVmax in primary cancer was 5,97 in the prostate gland and 3,2 in pelvic lymph nodes. Patients with recurrent cancer had a mean SUVmax of 4,38. Two patients had negative PET/CT scans. At 28 months the overall survival rate is 94%. Biochemical relapse free survival is 83% for primary cancer and 49% for recurrent tumours. Distant disease free survival is 100% and 75% for primary and recurrent cancer, respectively. Acute normal tissue toxicity was mild in 85% and moderate (grade 2 in 15%. No or mild late side effects were observed in the majority of patients (84%. One patient had

  4. Modelling Toehold-Mediated RNA Strand Displacement

    OpenAIRE

    Šulc, Petr; Ouldridge, Thomas E.; Romano, Flavio; Doye, Jonathan P.K.; Louis, Ard A.

    2015-01-01

    We study the thermodynamics and kinetics of an RNA toehold-mediated strand displacement reaction with a recently developed coarse-grained model of RNA. Strand displacement, during which a single strand displaces a different strand previously bound to a complementary substrate strand, is an essential mechanism in active nucleic acid nanotechnology and has also been hypothesized to occur in vivo. We study the rate of displacement reactions as a function of the length of the toehold and temperat...

  5. Brain perfusion-CT in acute stroke patients

    International Nuclear Information System (INIS)

    Andreev, T.; Totsev, N.; Tzvetanov, P.

    2013-01-01

    Since 1979 when Grodfrey Hounsfield and Allan Corman introduced the computed tomography new generations of CT were developed that improved the special resolution and time of acquisition. The role of neuro-imaging in the evaluation of acute stroke has changed dramatically in the past decade. Previously, neuro-imaging was used in this set-ting to provide anatomic imaging that indicated the presence or absence of acute cerebral ischemia and excluded lesions that produce symptoms or signs mimicking those of stroke, such as hemorrhage and neoplasms. More recently, the introduction of thrombolysis has changed the goals of neuro-imaging from providing solely anatomic information to providing physiologic information that could help to determine which patients might benefit from therapy. In particular, significant emphasis has been placed on the delineation of the ischemic penumbra, also called tissue at risk. Modem CT survey, consisting of three indissociable elements; noncontrast CT (NCT) of course, perfusion-CT (PCT) and CT-angiography (CTA), fulfill all the requirements for hyperacute stroke imaging. CTA can define the occlusion site, depict arterial dissection, grade collateral blood flow, and characterize atherosclerotic disease, whereas PCT accurately defines the infarct core and the ischemic penumbra. CT offers a number of practical advantages over other cerebral perfusion imaging methods, including its wide availability. Using PCT and CTA to define new individualized strategies for acute reperfusion will allow more acute stroke patients to benefit from thrombolytic therapy. Key words: Stroke. Penumbra. Computed Tomography. Perfusion-CT. CT Angiography. Outcome

  6. Object-constrained meshless deformable algorithm for high speed 3D nonrigid registration between CT and CBCT

    International Nuclear Information System (INIS)

    Chen Ting; Kim, Sung; Goyal, Sharad; Jabbour, Salma; Zhou Jinghao; Rajagopal, Gunaretnum; Haffty, Bruce; Yue Ning

    2010-01-01

    Purpose: High-speed nonrigid registration between the planning CT and the treatment CBCT data is critical for real time image guided radiotherapy (IGRT) to improve the dose distribution and to reduce the toxicity to adjacent organs. The authors propose a new fully automatic 3D registration framework that integrates object-based global and seed constraints with the grayscale-based ''demons'' algorithm. Methods: Clinical objects were segmented on the planning CT images and were utilized as meshless deformable models during the nonrigid registration process. The meshless models reinforced a global constraint in addition to the grayscale difference between CT and CBCT in order to maintain the shape and the volume of geometrically complex 3D objects during the registration. To expedite the registration process, the framework was stratified into hierarchies, and the authors used a frequency domain formulation to diffuse the displacement between the reference and the target in each hierarchy. Also during the registration of pelvis images, they replaced the air region inside the rectum with estimated pixel values from the surrounding rectal wall and introduced an additional seed constraint to robustly track and match the seeds implanted into the prostate. The proposed registration framework and algorithm were evaluated on 15 real prostate cancer patients. For each patient, prostate gland, seminal vesicle, bladder, and rectum were first segmented by a radiation oncologist on planning CT images for radiotherapy planning purpose. The same radiation oncologist also manually delineated the tumor volumes and critical anatomical structures in the corresponding CBCT images acquired at treatment. These delineated structures on the CBCT were only used as the ground truth for the quantitative validation, while structures on the planning CT were used both as the input to the registration method and the ground truth in validation. By registering the planning CT to the CBCT, a

  7. Characterization of large instabilities displacements using Ground-Based InSAR

    Science.gov (United States)

    Rouyet, L.; Kristensen, L.; Derron, M.-H.; Michoud, C.; Blikra, L. H.; Jaboyedoff, M.

    2012-04-01

    A master thesis in progress at the Lausanne University (IGAR) in cooperation with the Åknes/Tafjord Early Warning Centre in Norway aims to characterize various instabilities displacements using Ground-Based Interferometric Synthetic Aperture Radar system (GB-InSAR). The main goal is to evaluate the potential of GB-InSAR to determine displacement velocities and mechanical behaviours of several large rock instabilities in Norway. GB-InSAR data are processed and interpreted for three case studies. The first test site is the unstable complex area of Mannen located in the Romsdalen valley (Møre og Romsdal county), threatening infrastructures and potentially able to cause a debacle event downstream. Its total volume is estimated to 15-25 mill m3. Mannen instability is monitored permanently with GB-InSAR since February 2010 and shows displacements towards the radar up to -8 mm per month during the most sensitive period. Børa area located on the southwest side of Mannen instability shows also some signs of activity. It monitored temporarily between August and October 2011 and could help to understand the behaviour of Mannen site. The second, Indre Nordnes rockslide in Lyngenfjord (Troms county), is directly located above an important fjord in North Norway causing a significant risk of tsunami. The volume is estimated to be around 10-15 mill m3. The site was monitored temporarily between June and August 2011. The data show displacements towards the radar up to -12 mm in 2 weeks. The third case concerns rock falls along the road between Oppdølsstranda and Sunndalsøra (Møre og Romsdal county). Even if the volume of rock is less important than the first two cases, rock falls are an important problem for the road 70 underneath. Several campaigns are done between beginning of 2010 and end of 2011. In June 2011 an important rock fall occurs in an area where significant movements were previously detected by GB-InSAR. In order to understand the behaviour of these

  8. Measurement of interfacial displacement of a liquid film in microchannels using laser focus displacement meter

    International Nuclear Information System (INIS)

    Hazuku, Tatsuya; Fukamachi, Norihiro; Takamasa, Tomoji; Hibiki, Takashi

    2004-01-01

    This paper presents a new method for measuring the interfacial displacement of a liquid film in microchannels using a laser focus displacement meter (LFD). The purpose of the study is to clarify the effectiveness of the new method for obtaining detailed information concerning interfacial displacement, especially in the case of a thin liquid film, in micro- and mini-channels. To prevent the tube wall signal from disturbing that of the gas-liquid interface, a fluorocarbon tube with water box was used; the refraction index of this device is same as that for water. With this method, accurate instantaneous measurements of interfacial displacement of the liquid film were achieved. The error caused by refraction of the laser beam passing through the acrylic water box and fluorocarbon tube was estimated analytically and experimentally. The formulated analytical equation can estimate the real interface displacement using measured displacement in a fluorocarbon tube of 25 μm to 2.0 mm I.D. A preliminary test using fluorocarbon tubes of 1 and 2 mm I.D. showed that the corrected interface displacement calculated by the equation agreed with real displacement within a 1% margin of error. It was also confirmed that the LFD in the system could measure a liquid film of 0.25 μm at the thinnest. We made simultaneous measurements of the interface in fluorocarbon tubes of 0.5 and 1 mm I.D. using the LFD and a high-speed video camera with a microscope. These showed that the LFD could measure the interface of a liquid film with high spatial and temporal resolution during annular, slug, and piston flow regimes. The data also clarified the existence of a thin liquid film less than 1 μm in thickness in slug and annular flow regions. (author)

  9. Technical procedures for the implementation of cultural resource site studies, Deaf Smith County, Texas: Preliminary draft

    International Nuclear Information System (INIS)

    1987-01-01

    Cultural resources at the Deaf Smith County site will be identified, evaluated and managed through the implementation of studies detailed in the Site Study Plan for Cultural Resources. This technical procedure outlines the conduct of pedestrian survey and the documentation of identified cultural resources. The purpose of the field surveys is to identify and document cultural resources in the areas that will be affected by site characterization activities and to record the environmental setting of identified cultural resources. Three pedestrian surveys will cover 100 percent of the on-site and off-site project areas. Survey 1 will provide coverage of the Repository Surface Facility (RSF) area, which includes the Exploratory Shaft Facility (ESF) and two linear engineering design borehole (EDBH) seismic survey corridors. Survey 2 will provide coverage of a 39 km 2 (15 mi 2 ) area that includes the 23 km 2 (9 mi 2 ) Deaf Smith County site plus a 0.4 to 0.8 kM (1/4 to 1/2 mi) border area but excludes the area covered by Survey 1. Survey 3 will cover offsite geotechnical test areas, such as the locations of playa boreholes, deep playa wells, hydrologic tests, site foundation borings, and their access routes. The purpose of site documentation or recording is to address the project information needs for land use permits and approvals, engineering design support, and cultural resource evaluation for National Register of Historic Places eligibility. Site documentation will consist of gathering sufficient data on identified resources to complete Texas Natural Resource Information System (TNRIS). 7 refs., 3 figs

  10. On-line cone beam CT image guidance for vocal cord tumor targeting

    International Nuclear Information System (INIS)

    Osman, Sarah O.S.; Boer, Hans C.J. de; Astreinidou, Eleftheria; Gangsaas, Anne; Heijmen, Ben J.M.; Levendag, Peter C.

    2009-01-01

    Background and purpose: We are developing a technique for highly focused vocal cord irradiation in early glottic carcinoma to optimally treat a target volume confined to a single cord. This technique, in contrast with the conventional methods, aims at sparing the healthy vocal cord. As such a technique requires sub-mm daily targeting accuracy to be effective, we investigate the accuracy achievable with on-line kV-cone beam CT (CBCT) corrections. Materials and methods: CBCT scans were obtained in 10 early glottic cancer patients in each treatment fraction. The grey value registration available in X-ray volume imaging (XVI) software (Elekta, Synergy) was applied to a volume of interest encompassing the thyroid cartilage. After application of the thus derived corrections, residue displacements with respect to the planning CT scan were measured at clearly identifiable relevant landmarks. The intra- and inter-observer variations were also measured. Results: While before correction the systematic displacements of the vocal cords were as large as 2.4 ± 3.3 mm (cranial-caudal population mean ± SD Σ), daily CBCT registration and correction reduced these values to less than 0.2 ± 0.5 mm in all directions. Random positioning errors (SD σ) were reduced to less than 1 mm. Correcting only for translations and not for rotations did not appreciably affect this accuracy. The residue random displacements partly stem from intra-observer variations (SD = 0.2-0.6 mm). Conclusion: The use of CBCT for daily image guidance in combination with standard mask fixation reduced systematic and random set-up errors of the vocal cords to <1 mm prior to the delivery of each fraction dose. Thus, this facilitates the high targeting precision required for a single vocal cord irradiation.

  11. Neurosurgical operating computerized tomographic scanner system. The CT scanner in the operating theater

    Energy Technology Data Exchange (ETDEWEB)

    Okudera, Hiroshi; Sugita, Kenichiro; Kobayashi, Shigeaki; Kimishima, Sakae; Yoshida, Hisashi

    1988-12-01

    A neurosurgical operating computerized tomography scanner system is presented. This system has been developed for obtaining intra- and postoperative CT images in the operating room. A TCT-300 scanner (manufactured by the Toshiba Co., Tokyo) is placed in the operating room. The realization of a true intraoperative CT image requires certain improvements in the CT scanner and operating table. To adjust the axis of the co-ordinates of the motor system of the MST-7000 microsurgical operating table (manufactured by the Mizuho Ika Co., Tokyo) to the CT scanner, we have designed an interface and a precise motor system so that the computer of the CT scanner can directly control the movement of the operating table. Furthermore, a new head-fixation system has been designed for producing artifact-free intraoperative CT images. The head-pins of the head-fixation system are made of carbon-fiber bars and titanium tips. A simulation study of the total system in the operating room with the CT scanner, operating table, and head holder using a skull model yielded a degree of error similar to that in the phantom testing of the original scanner. Three patients underwent resection of a glial tumor using this system. Intraoperative CT scans taken after dural opening showed a bulging of the cortex, a shift in the central structure, and a displacement of the cortical subarachnoid spaces under the influence of gravity. With a contrast medium the edge of the surrounding brain after resection was enhanced and the residual tumor mass was demonstrated clearly. This system makes it possible to obtain a noninvasive intraoperative image in a situation where structural shifts are taking place.

  12. The role of CT in oncology irigography

    International Nuclear Information System (INIS)

    Hako, R.; Gulova, I.

    2013-01-01

    Colorectal cancer is a common malignancy that results in significant morbidity and mortality. CT irigography is an evolving noninvasive imaging technique that relies on performing thin-section CT of the colon evaluating data using both 2D and 3D images. A clean and well-distended colon facilitates detection of colorectal abnormalities whether 2D and 3D techniques are used for data interpretation. Is valuable in planning surgery for colon cancer because it can demonstrate regional extension of tumor as well as adenopathy and distant metastases. Also complications of primary colonic malignancies such as obstructions, perforations, and fistulas can be readily visualized with CT irigography. The liver is the predominant organ to be involved with metastases from colorectal cancer. Other common sites of metastases from colon cancer include the lungs, adrenal glands, and bones. CT is applicable for identifying recurrences, evaluating anatomic relationships, documenting normal postoperative anatomy, and confirming the absence of new lesions during and after therapy. (author)

  13. Extraction of airways from CT (EXACT’09)

    DEFF Research Database (Denmark)

    Lo, Pechin Chien Pau; Ginneken, Bram van; Reinhardt, Joseph M.

    2012-01-01

    or not it is a correctly segmented part of the airway tree. Finally, the reference airway trees are constructed by taking the union of all correctly extracted branch segments. Fifteen airway tree extraction algorithms from different research groups are evaluated on a diverse set of 20 chest computed tomography (CT) scans...... of subjects ranging from healthy volunteers to patients with severe pathologies, scanned at different sites, with different CT scanner brands, models, and scanning protocols. Three performance measures covering different aspects of segmentation quality were computed for all participating algorithms. Results...

  14. Quantitative measurement of lung density with x-ray CT and positron CT, (2). Diseased subjects

    Energy Technology Data Exchange (ETDEWEB)

    Ito, Kengo; Ito, Masatoshi; Kubota, Kazuo

    1985-05-01

    Lung density was quantitatively measured on six diseased patients with X-ray CT (XCT) and Positron CT(PCT). The findings are as follows: In the silicosis, extravascular lung density was found to be remarkably increased compared to normals (0.29gcm/sup 3/), but blood volume was in normal range. In the post-irradiated lung cancers, extravascular lung density increased in the irradiated sites compared to the non-irradiated opposite sites, and blood volume varied in each case. In a patient with chronic heart failure, blood volume decreased (0.11mlcm/sup 3/) with increased extravascular lung density (0.23gcm/sup 3/). In the chronic obstructive pulmonary disease, both extravascular lung density and blood volume decreased (0.11gcm/sup 3/ and 0.10mlcm/sup 3/ respectively). Lung density measured with XCT was constantly lower than that with PCT in all cases. But changes in the values of lung density measured, correlated well with each other. In conclusion, the method presented here may clarify the etiology of the diffuse pulmonary diseases, and be used to differentiate and grade the diseases.

  15. Effects of faults as barriers or conduits to displaced brine flow on a putative CO2 storage site in the Southern North Sea

    Science.gov (United States)

    Hannis, Sarah; Bricker, Stephanie; Williams, John

    2013-04-01

    The Bunter Sandstone Formation in the Southern North Sea is a potential reservoir being considered for carbon dioxide storage as a climate change mitigation option. A geological model of a putative storage site within this saline aquifer was built from 3D seismic and well data to investigate potential reservoir pressure changes and their effects on fault movement, brine and CO2 migration as a result of CO2 injection. The model is located directly beneath the Dogger Bank Special Area of Conservation, close to the UK-Netherlands median line. Analysis of the seismic data reveals two large fault zones, one in each of the UK and Netherlands sectors, many tens of kilometres in length, extending from reservoir level to the sea bed. Although it has been shown that similar faults compartmentalise gas fields elsewhere in the Netherlands sector, significant uncertainty remains surrounding the properties of the faults in our model area; in particular their cross- and along-fault permeability and geomechanical behaviour. Despite lying outside the anticipated CO2 plume, these faults could provide potential barriers to pore fluid migration and pressure dissipation, until, under elevated pressures, they provide vertical migration pathways for brine. In this case, the faults will act to enhance injectivity, but potential environmental impacts, should the displaced brine be expelled at the sea bed, will require consideration. Pressure gradients deduced from regional leak-off test data have been input into a simple geomechanical model to estimate the threshold pressure gradient at which faults cutting the Mesozoic succession will fail, assuming reactivation of fault segments will cause an increase in vertical permeability. Various 4D scenarios were run using a single-phase groundwater modelling code, calibrated to results from a multi-phase commercial simulator. Possible end-member ranges of fault parameters were input to investigate the pressure change with time and quantify brine

  16. Automated movement correction for dynamic PET/CT images: evaluation with phantom and patient data.

    Science.gov (United States)

    Ye, Hu; Wong, Koon-Pong; Wardak, Mirwais; Dahlbom, Magnus; Kepe, Vladimir; Barrio, Jorge R; Nelson, Linda D; Small, Gary W; Huang, Sung-Cheng

    2014-01-01

    Head movement during a dynamic brain PET/CT imaging results in mismatch between CT and dynamic PET images. It can cause artifacts in CT-based attenuation corrected PET images, thus affecting both the qualitative and quantitative aspects of the dynamic PET images and the derived parametric images. In this study, we developed an automated retrospective image-based movement correction (MC) procedure. The MC method first registered the CT image to each dynamic PET frames, then re-reconstructed the PET frames with CT-based attenuation correction, and finally re-aligned all the PET frames to the same position. We evaluated the MC method's performance on the Hoffman phantom and dynamic FDDNP and FDG PET/CT images of patients with neurodegenerative disease or with poor compliance. Dynamic FDDNP PET/CT images (65 min) were obtained from 12 patients and dynamic FDG PET/CT images (60 min) were obtained from 6 patients. Logan analysis with cerebellum as the reference region was used to generate regional distribution volume ratio (DVR) for FDDNP scan before and after MC. For FDG studies, the image derived input function was used to generate parametric image of FDG uptake constant (Ki) before and after MC. Phantom study showed high accuracy of registration between PET and CT and improved PET images after MC. In patient study, head movement was observed in all subjects, especially in late PET frames with an average displacement of 6.92 mm. The z-direction translation (average maximum = 5.32 mm) and x-axis rotation (average maximum = 5.19 degrees) occurred most frequently. Image artifacts were significantly diminished after MC. There were significant differences (Pdynamic brain FDDNP and FDG PET/CT scans could improve the qualitative and quantitative aspects of images of both tracers.

  17. Repair of abasic sites in DNA

    Energy Technology Data Exchange (ETDEWEB)

    Dianov, Grigory L.; Sleeth, Kate M.; Dianova, Irina I.; Allinson, Sarah L

    2003-10-29

    Repair of both normal and reduced AP sites is activated by AP endonuclease, which recognizes and cleaves a phosphodiester bond 5' to the AP site. For a short period of time an incised AP site is occupied by poly(ADP-ribose) polymerase and then DNA polymerase {beta} adds one nucleotide into the repair gap and simultaneously removes the 5'-sugar phosphate. Finally, the DNA ligase III/XRCC1 complex accomplishes repair by sealing disrupted DNA ends. However, long-patch BER pathway, which is involved in the removal of reduced abasic sites, requires further DNA synthesis resulting in strand displacement and the generation of a damage-containing flap that is later removed by the flap endonuclease. Strand-displacement DNA synthesis is accomplished by DNA polymerase {delta}/{epsilon} and DNA ligase I restores DNA integrity. DNA synthesis by DNA polymerase {delta}/{epsilon} is dependent on proliferating cell nuclear antigen, which also stimulates the DNA ligase I and flap endonuclease. These repair events are supported by multiple protein-protein interactions.

  18. The use of MRI and CT in Imaging Occult Hip Fractures

    Directory of Open Access Journals (Sweden)

    Obadă B.

    2014-11-01

    Full Text Available Diagnosis of hip fractures is particularly important due to the high dependence on the integrity of this structure for people to function in their daily lives. Left unrecognized, patients face increasing morbidity and mortality as time from the original injury lengthens. A delay of just 2 days in surgical treatment for an acute hip fracture doubles mortality. In addition, an unrecognized non-displaced fracture may displace, requiring surgery of much higher risk. This may be part of the reason that the most frequent lawsuit against Emergency Physicians is for missed orthopedic injury. We reviewed the use of MRI and CT for occult hip fractures (OHF detection at a major urban trauma unit. Our study is a retrospective review. Inclusion criteria: all patients presenting to the Emergency Clinical Hospital of Constanta with a suspected, posttraumatic, occult hip fracture, over a 5 years period were included. All patients had negative initial radiographs and underwent further imaging with either CT or MRI. A total of 185 cases meeting the inclusion criteria were identified. 72 occult hip fractures were detected with both imaging modalities. Although MRI certainly enables greater image detail, in our experience both modalities are able to provide satisfactory fracture characterization. The choice of imaging should be determined by availability and indication. MRI provides superior imaging of soft tissue but is less sensitive for degenerative changes in presence of bone edema.

  19. CT findings of rectosigmoid carcinoma showing exophytic growth

    International Nuclear Information System (INIS)

    Ohgi, Kazuyuki; Kohno, Atsushi; Higuchi, Mutsumi

    1987-01-01

    CT findings of 7 rectosigmoid carcinomas showing exophytic growth were evaluated. All cases had bulky masses, ranging from 6.0 to 11.5 cm in maximum diameter. All masses were difficult to differentiate from the other pelvic masses on CT, presumably due to their exophytic growth and/or invasion to the surrounding organs. However, 3 out of 7 cases showed diffuse rectosigmoidal wall thickening adjacent to the primary tumor, and it is considered to be valuable in the determination of primary site. All female cases had gynecological symptom such as genital bleeding, due to uterine and/or vaginal invasion. When indeterminate pelvic mass is revealed by CT, rectosigmoid carcinoma should be considered into differential diagnosis. (author)

  20. Etiopathogenesis of abomasal displacement in cattle

    Directory of Open Access Journals (Sweden)

    Šamanc Horea

    2003-01-01

    Full Text Available Abomasal displacement presents topographic gastropathy, where this organ has changed its position, and there is simultaneous dilatation which can vary in intensity. The incidence of this disorder in herds of high-yield dairy cows varies to a great degree (1 to 18 %. Abomasal displacement was established in herds of East-Frisian cows in 1 to 3% animals, and in Holstein cow herds in 5 to 18 % animals. The most frequent abomasal displacement is to the left (88%. There is significant seasonal variation in the incidence of abomasal displacement. About two-thirds of cases of abomasal displacement are diagnosed from October until April. The disorder appears more frequently in cows with repeated lactations. It has been established that it appears after the first calving in 27.8% cases, after the second to fifth calving in 66.7% cases, and after the sixth and seventh calving in 5.5% of the cows. The response of endocrine pancreas B-cells for insulin secretion to hyperglycaemia caused by applying an excess-glucose test is reduced in cows with left abomasal displacement, and there is constant hyperglycaemia in cows with right abomasal displacement. The excess-glucose test indicates a disrupted function of the endocrine pancreas in diseased animals. It has been determined through examinations of Aml genotypes in Holstein cow herds in connection with the appearance of abomasal displacement, that the occurrence of this disorder cannot be attributed to a genetic predisposition.

  1. Theory of atom displacements induced by fast electron elastic scattering in solids

    International Nuclear Information System (INIS)

    Cruz, C. M.; Pinera, I.; Abreu, Y.; Leyva, A.

    2006-01-01

    Present contribution deals with the theoretical description of the conditions favoring the occurrence of single fast electron elastic scattering in solids, leading to the displacement of atoms from their crystalline sites. Firstly, the Moliere-Bethe-Goudsmit-Saunderson theory of Multiple Electron Scattering is applied, determining the limiting angle θ l over which the single electron elastic scattering prevails over the multiple one, leading to the evaluation of the total macroscopic cross-section for single electron elastic scattering on the basis of the Mott-Rutherford differential cross-section. On the basis of single electron elastic scattering by atoms in the solid matrix, it was determined the relative number of Atom Displacements produced by the Gamma Radiation as a primary act, as well as the energy and linear momentum of the ejected atoms. The statistical distributions of single electron elastic scattering and of those inducing Atom Displacements at different electron initial energies in comparison with the others electron inelastic scattering channels are discussed, where the statistical sampling methods on the basis of the rejection one where applied simulating different practical situations. (Full text)

  2. Conflict, displacement and health in the Middle East.

    Science.gov (United States)

    Mowafi, Hani

    2011-01-01

    Displacement is a hallmark of modern humanitarian emergencies. Displacement itself is a traumatic event that can result in illness or death. Survivors face challenges including lack of adequate shelter, decreased access to health services, food insecurity, loss of livelihoods, social marginalisation as well as economic and sexual exploitation. Displacement takes many forms in the Middle East and the Arab World. Historical conflicts have resulted in long-term displacement of Palestinians. Internal conflicts have driven millions of Somalis and Sudanese from their homes. Iraqis have been displaced throughout the region by invasion and civil strife. In addition, large numbers of migrants transit Middle Eastern countries or live there illegally and suffer similar conditions as forcibly displaced people. Displacement in the Middle East is an urban phenomenon. Many displaced people live hidden among host country populations in poor urban neighbourhoods - often without legal status. This represents a challenge for groups attempting to access displaced populations. Furthermore, health information systems in host countries often do not collect data on displaced people, making it difficult to gather data needed to target interventions towards these vulnerable populations. The following is a discussion of the health impacts of conflict and displacement in the Middle East. A review was conducted of published literature on migration and displacement in the region. Different cases are discussed with an emphasis on the recent, large-scale and urban displacement of Iraqis to illustrate aspects of displacement in this region.

  3. Simulated annealing of displacement cascades in FCC metals. 1. Beeler cascades

    International Nuclear Information System (INIS)

    Doran, D.G.; Burnett, R.A.

    1974-09-01

    An important source of damage to structural materials in fast reactors is the displacement of atoms from normal lattice sites. A high energy neutron may impart sufficient energy to an atom to initiate a displacement cascade consisting of a localized high density of hundreds of interstitials and vacancies. These defects subsequently interact to form clusters and to reduce their density by mutual annihilation. This short term annealing of an isolated cascade has been simulated at high and low temperatures using a correlated random walk model. The cascade representations used were developed by Beeler and the point defect properties were based on the model of γ-iron by Johnson. Low temperature anneals, characterized by no vacancy migration and a 104 site annihilation region (AR), resulted in 49 defect pairs at 20 keV and 11 pairs at 5 keV. High temperature anneals, characterized by both interstitial and vacancy migration and a 32 site AR, resulted in 68 pairs at 20 keV and 18 pairs at 5 keV when no cluster dissociation was permitted; most of the vacancies were in immobile clusters. These high temperature values dropped to 40 and 14 upon dissolution of the vacancy clusters. Parameter studies showed that, at a given temperature, the large AR resulted in about one-half as many defects as the small AR. Cluster size distributions and examples of spatial configurations are included. (U.S.)

  4. Comparison of CT numbers between cone-beam CT and multi-detector CT

    International Nuclear Information System (INIS)

    Kim, Dong Soo; Han, Won Jeong; Kim, Eun Kyung

    2010-01-01

    To compare the CT numbers on 3 cone-beam CT (CBCT) images with those on multi-detector CT (MDCT) image using CT phantom and to develop linear regressive equations using CT numbers to material density for all the CT scanner each. Mini CT phantom comprised of five 1 inch thick cylindrical models with 1.125 inches diameter of materials with different densities (polyethylene, polystyrene, plastic water, nylon and acrylic) was used. It was scanned in 3 CBCTs (i-CAT, Alphard VEGA, Implagraphy SC) and 1 MDCT (Somatom Emotion). The images were saved as DICOM format and CT numbers were measured using OnDemand 3D. CT numbers obtained from CBCTs and MDCT images were compared and linear regression analysis was performed for the density, ρ(g/cm 3 ), as the dependent variable in terms of the CT numbers obtained from CBCTs and MDCT images. CT numbers on i-CAT and Implagraphy CBCT images were smaller than those on Somatom Emotion MDCT image (p<0.05). Linear relationship on a range of materials used for this study were ρ=0.001 H+1.07 with R2 value of 0.999 for Somatom Emotion, ρ=0.002 H+1.09 with R2 value of 0.991 for Alphard VEGA, ρ=0.001 H+1.43 with R2 value of 0.980 for i-CAT and ρ=0.001 H+1.30 with R2 value of 0.975 for Implagraphy. CT numbers on i-CAT and Implagraphy CBCT images were not same as those on Somatom Emotion MDCT image. The linear regressive equations to determine the density from the CT numbers with very high correlation coefficient were obtained on three CBCT and MDCT scan.

  5. Comparison of CT numbers between cone-beam CT and multi-detector CT

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dong Soo; Han, Won Jeong; Kim, Eun Kyung [Department of Oral and Maxillofacial Radiology, School of Dentistry, Dankook University, Cheonan (Korea, Republic of)

    2010-06-15

    To compare the CT numbers on 3 cone-beam CT (CBCT) images with those on multi-detector CT (MDCT) image using CT phantom and to develop linear regressive equations using CT numbers to material density for all the CT scanner each. Mini CT phantom comprised of five 1 inch thick cylindrical models with 1.125 inches diameter of materials with different densities (polyethylene, polystyrene, plastic water, nylon and acrylic) was used. It was scanned in 3 CBCTs (i-CAT, Alphard VEGA, Implagraphy SC) and 1 MDCT (Somatom Emotion). The images were saved as DICOM format and CT numbers were measured using OnDemand 3D. CT numbers obtained from CBCTs and MDCT images were compared and linear regression analysis was performed for the density, {rho}(g/cm{sup 3}), as the dependent variable in terms of the CT numbers obtained from CBCTs and MDCT images. CT numbers on i-CAT and Implagraphy CBCT images were smaller than those on Somatom Emotion MDCT image (p<0.05). Linear relationship on a range of materials used for this study were {rho}=0.001 H+1.07 with R2 value of 0.999 for Somatom Emotion, {rho}=0.002 H+1.09 with R2 value of 0.991 for Alphard VEGA, {rho}=0.001 H+1.43 with R2 value of 0.980 for i-CAT and {rho}=0.001 H+1.30 with R2 value of 0.975 for Implagraphy. CT numbers on i-CAT and Implagraphy CBCT images were not same as those on Somatom Emotion MDCT image. The linear regressive equations to determine the density from the CT numbers with very high correlation coefficient were obtained on three CBCT and MDCT scan.

  6. Development of a CT simulator and its current clinical status

    International Nuclear Information System (INIS)

    Nagata, Yasushi; Hiraoka, Masahiro; Nishidai, Takehiro

    2000-01-01

    A computed tomography (CT) simulator is defined as a radiotherapy treatment planning (RTP) system which consists of an X-ray CT scanner, a treatment planning computer, and a marking projector. The developmental process from the introduction of an X-ray CT to a CT simulator is described in this article. After the development of the first CT simulator, several new developments in CT scanners, marking projector, and data transfer networks were introduced. CT simulator systems have recently become more widely available and are produced by more than 8 commercial companies. The advantages of a CT simulator are a shortening of overall RTP time, increased accuracy of RTP, and the possibility of 3-D conformal therapy. Clinical experience with CT simulators has accumulated over the past 10 years. Site-specific trials have been undertaken, and the clinical usefulness of CT simulators for breast cancer, maxillary cancer, nasopharyngeal cancer, orbital tumor, lung cancer and other tumors has been demonstrated. The use of CT simulators has resulted in a decrease in the complications of radiotherapy. It also appears to be an essential tool for dose escalation studies, which may permit increased local control of certain tumors. In Japan, CT simulators were in use at more than 134 (20%) of 682 radiotherapy institutions as of the end of 1998. In the USA, CT simulators were present in more than 12% of 1,542 radiotherapy centers in 1994. The CT simulator is now an essential RTP system for advanced radiotherapy. (author)

  7. Displacement sensing system and method

    Science.gov (United States)

    VunKannon, Jr., Robert S

    2006-08-08

    A displacement sensing system and method addresses demanding requirements for high precision sensing of displacement of a shaft, for use typically in a linear electro-dynamic machine, having low failure rates over multi-year unattended operation in hostile environments. Applications include outer space travel by spacecraft having high-temperature, sealed environments without opportunity for servicing over many years of operation. The displacement sensing system uses a three coil sensor configuration, including a reference and sense coils, to provide a pair of ratio-metric signals, which are inputted into a synchronous comparison circuit, which is synchronously processed for a resultant displacement determination. The pair of ratio-metric signals are similarly affected by environmental conditions so that the comparison circuit is able to subtract or nullify environmental conditions that would otherwise cause changes in accuracy to occur.

  8. Displacement of screw-retained single crowns into implants with conical internal connections.

    Science.gov (United States)

    Yilmaz, Burak; Seidt, Jeremy D; McGlumphy, Edwin A; Clelland, Nancy L

    2013-01-01

    Internal conical implant-abutment connections without platforms may lead to axial displacement of crowns during screw tightening. This displacement may affect proximal contacts, incisal edge position, or occlusion. This study aimed to measure the displacement of screw-retained single crowns into an implant in three dimensions during screw tightening by hand or via torque driver. A stereolithic acrylic resin cast was created using computed tomography data from a patient missing the maxillary right central incisor. A 4.0- × 11-mm implant was placed in the edentulous site. Five porcelain-fused-to-metal single crowns were made using "cast-to" abutments. Crowns were tried on the stereolithic model, representing the patient, and hand tightened. The spatial relationship of crowns to the model after hand tightening was determined using three-dimensional digital image correlation (3D DIC), an optical measurement technique. The crowns were then tightened using a torque driver to 20 Ncm and the relative crown positions were again recorded. Testing was repeated three times for each crown, and displacement of the crowns was compared between the hand-tightened and torqued states. Commercial image correlation software was used to analyze the data. Mean vertical and horizontal crown displacement values were calculated after torqueing. The interproximal contacts were evaluated before and after torquing using an 8-μm aluminum foil shim. There were vertical and horizontal differences in crown positions between hand tightening and torqueing. Although these were small in magnitude, detectable displacements occurred in both apical and facial directions. After hand tightening, the 8-μm shim could be dragged without tearing. However, after torque tightening, the interproximal contacts were too tight and the 8-μm shim could not be dragged without tearing. Differences between hand tightening and torque tightening should be taken into consideration during laboratory and clinical

  9. Effects of Fault Displacement on Emplacement Drifts

    International Nuclear Information System (INIS)

    Duan, F.

    2000-01-01

    The purpose of this analysis is to evaluate potential effects of fault displacement on emplacement drifts, including drip shields and waste packages emplaced in emplacement drifts. The output from this analysis not only provides data for the evaluation of long-term drift stability but also supports the Engineered Barrier System (EBS) process model report (PMR) and Disruptive Events Report currently under development. The primary scope of this analysis includes (1) examining fault displacement effects in terms of induced stresses and displacements in the rock mass surrounding an emplacement drift and (2 ) predicting fault displacement effects on the drip shield and waste package. The magnitude of the fault displacement analyzed in this analysis bounds the mean fault displacement corresponding to an annual frequency of exceedance of 10 -5 adopted for the preclosure period of the repository and also supports the postclosure performance assessment. This analysis is performed following the development plan prepared for analyzing effects of fault displacement on emplacement drifts (CRWMS M and O 2000). The analysis will begin with the identification and preparation of requirements, criteria, and inputs. A literature survey on accommodating fault displacements encountered in underground structures such as buried oil and gas pipelines will be conducted. For a given fault displacement, the least favorable scenario in term of the spatial relation of a fault to an emplacement drift is chosen, and the analysis is then performed analytically. Based on the analysis results, conclusions are made regarding the effects and consequences of fault displacement on emplacement drifts. Specifically, the analysis will discuss loads which can be induced by fault displacement on emplacement drifts, drip shield and/or waste packages during the time period of postclosure

  10. Experimental validation of a numerical model of two-phase displacement in porous medium

    International Nuclear Information System (INIS)

    Genty, A.

    1996-01-01

    Burial in geological layers appears to be an interesting solution to dispose of radioactive wastes. This thesis analyzes and simulates the behaviour of gas produced by waste barrels corrosion. The released contaminated gas drains the water initially present in the host rock and yields a water-gas two phase flow. A literature survey of two phase flow shows that fluid interfaces may display instabilities for definite flow characteristics. When the displacement is stable a smooth interface proceeds through the porous medium. When the interface shows fingering, the displacement is said to be 'viscous-unstable', and when the front is jagged the displacement is called 'capillary' displacement. A dimensional analysis of classical equations governing two phase flow in porous media is combined with a classification of dominant forces to define an original map of flow regimes that includes gravitational forces. The map is based on three dimensionless numbers and predicts a priori the flow type. For typical data describing a radioactive waste repository a 'viscous-unstable' displacement is predicted by the map. We simulate water-gas displacement with a numerical model previously developed; this code, based on the Muskat model, uses the mixed-hybrid finite elements technique and is therefore well adapted for tracking moving interfaces. Fluxes are well conserved, however instabilities cannot be simulated. We assume that there is always a scale to be found where instabilities can be averaged and we try to validate the model with experimental two phase flows. We performed laboratory water-gas flow experiments for a variety of flow conditions. The observed displacement types are consistent with the map of flow regimes. Good agreement with numerical simulations is obtained when precise parameters of the displacements are available, in particular relative permeability curves. We conclude that our model allows a first approach of migration of gas near a radioactive waste repository

  11. TU-G-201-01: What Therapy Physicists Need to Know About CT and PET/CT: Terminology and Latest Developments

    International Nuclear Information System (INIS)

    Hua, C.

    2015-01-01

    , and PET/CT Understand the process of budget request, equipment justification, comparisons of technical specifications, site visits, vendor selection, and contract development

  12. TU-G-201-01: What Therapy Physicists Need to Know About CT and PET/CT: Terminology and Latest Developments

    Energy Technology Data Exchange (ETDEWEB)

    Hua, C. [St. Jude Childrens Research Hospital (United States)

    2015-06-15

    , and PET/CT Understand the process of budget request, equipment justification, comparisons of technical specifications, site visits, vendor selection, and contract development.

  13. Temporary organ displacement coupled with image-guided, intensity-modulated radiotherapy for paraspinal tumors

    International Nuclear Information System (INIS)

    Katsoulakis, Evangelia; Thornton, Raymond H; Yamada, Yoshiya; Solomon, Stephen B; Maybody, Majid; Housman, Douglas; Niyazov, Greg; Riaz, Nadeem; Lovelock, Michael; Spratt, Daniel E; Erinjeri, Joseph P

    2013-01-01

    To investigate the feasibility and dosimetric improvements of a novel technique to temporarily displace critical structures in the pelvis and abdomen from tumor during high-dose radiotherapy. Between 2010 and 2012, 11 patients received high-dose image-guided intensity-modulated radiotherapy with temporary organ displacement (TOD) at our institution. In all cases, imaging revealed tumor abutting critical structures. An all-purpose drainage catheter was introduced between the gross tumor volume (GTV) and critical organs at risk (OAR) and infused with normal saline (NS) containing 5-10% iohexol. Radiation planning was performed with the displaced OARs and positional reproducibility was confirmed with cone-beam CT (CBCT). Patients were treated within 36 hours of catheter placement. Radiation plans were re-optimized using pre-TOD OARs to the same prescription and dosimetrically compared with post-TOD plans. A two-tailed permutation test was performed on each dosimetric measure. The bowel/rectum was displaced in six patients and kidney in four patients. One patient was excluded due to poor visualization of the OAR; thus 10 patients were analyzed. A mean of 229 ml (range, 80–1000) of NS 5-10% iohexol infusion resulted in OAR mean displacement of 17.5 mm (range, 7–32). The median dose prescribed was 2400 cGy in one fraction (range, 2100–3000 in 3 fractions). The mean GTV D min and PTV D min pre- and post-bowel TOD IG-IMRT dosimetry significantly increased from 1473 cGy to 2086 cGy (p=0.015) and 714 cGy to 1214 cGy (p=0.021), respectively. TOD increased mean PTV D95 by 27.14% of prescription (p=0.014) while the PTV D05 decreased by 9.2% (p=0.011). TOD of the bowel resulted in a 39% decrease in mean bowel D max (p=0.008) confirmed by CBCT. TOD of the kidney significantly decreased mean kidney dose and D max by 25% (0.022). TOD was well tolerated, reproducible, and facilitated dose escalation to previously radioresistant tumors abutting critical structures while

  14. High-displacement spiral piezoelectric actuators

    Science.gov (United States)

    Mohammadi, F.; Kholkin, A. L.; Jadidian, B.; Safari, A.

    1999-10-01

    A high-displacement piezoelectric actuator, employing spiral geometry of a curved piezoelectric strip is described. The monolithic actuators are fabricated using a layered manufacturing technique, fused deposition of ceramics, which is capable of prototyping electroceramic components with complex shapes. The spiral actuators (2-3 cm in diameter) consisted of 4-5 turns of a lead zirconate titanate ceramic strip with an effective length up to 28 cm. The width was varied from 0.9 to 1.75 mm with a height of 3 mm. When driven by the electric field applied across the width of the spiral wall, the tip of the actuator was found to displace in both radial and tangential directions. The tangential displacement of the tip was about 210 μm under the field of 5 kV/cm. Both the displacement and resonant frequency of the spirals could be tailored by changing the effective length and wall width. The blocking force of the actuator in tangential direction was about 1 N under the field of 5 kV/cm. These properties are advantageous for high-displacement low-force applications where bimorph or monomorph actuators are currently employed.

  15. Generating patient specific pseudo-CT of the head from MR using atlas-based regression

    International Nuclear Information System (INIS)

    Sjölund, J; Forsberg, D; Andersson, M; Knutsson, H

    2015-01-01

    Radiotherapy planning and attenuation correction of PET images require simulation of radiation transport. The necessary physical properties are typically derived from computed tomography (CT) images, but in some cases, including stereotactic neurosurgery and combined PET/MR imaging, only magnetic resonance (MR) images are available. With these applications in mind, we describe how a realistic, patient-specific, pseudo-CT of the head can be derived from anatomical MR images. We refer to the method as atlas-based regression, because of its similarity to atlas-based segmentation. Given a target MR and an atlas database comprising MR and CT pairs, atlas-based regression works by registering each atlas MR to the target MR, applying the resulting displacement fields to the corresponding atlas CTs and, finally, fusing the deformed atlas CTs into a single pseudo-CT. We use a deformable registration algorithm known as the Morphon and augment it with a certainty mask that allows a tailoring of the influence certain regions are allowed to have on the registration. Moreover, we propose a novel method of fusion, wherein the collection of deformed CTs is iteratively registered to their joint mean and find that the resulting mean CT becomes more similar to the target CT. However, the voxelwise median provided even better results; at least as good as earlier work that required special MR imaging techniques. This makes atlas-based regression a good candidate for clinical use. (paper)

  16. Role of choline PET/CT in guiding target volume delineation for irradiation of prostate cancer

    Energy Technology Data Exchange (ETDEWEB)

    Schwarzenboeck, S.M.; Kurth, J. [University Medical Centre Rostock, Department of Nuclear Medicine, Rostock (Germany); Gocke, C.; Kuhnt, T.; Hildebrandt, G. [University Medical Centre Rostock, Department of Radiotherapy, Rostock (Germany); Krause, B.J. [University Medical Centre Rostock, Department of Nuclear Medicine, Rostock (Germany); Universitaet Rostock, Department of Nuclear Medicine, Universitaetsmedizin Rostock, Rostock (Germany)

    2013-07-15

    Choline PET/CT has shown limitations for the detection of primary prostate cancer and nodal metastatic disease, mainly due to limited sensitivity and specificity. Conversely in the restaging of prostate cancer recurrence, choline PET/CT is a promising imaging modality for the detection of local regional and nodal recurrence with an impact on therapy management. This review highlights current literature on choline PET/CT for radiation treatment planning in primary and recurrent prostate cancer. Due to limited sensitivity and specificity in differentiating between benign and malignant prostatic tissues in primary prostate cancer, there is little enthusiasm for target volume delineation based on choline PET/CT. Irradiation planning for the treatment of single lymph node metastases on the basis of choline PET/CT is controversial due to its limited lesion-based sensitivity in primary nodal staging. In high-risk prostate cancer, choline PET/CT might diagnose lymph node metastases, which potentially can be included in the conventional irradiation field. Prior to radiation treatment of recurrent prostate cancer, choline PET/CT may prove useful for patient stratification by excluding distant disease which would require systemic therapy. In patients with local recurrence, choline PET/CT can be used to delineate local sites of recurrence within the prostatic resection bed allowing a boost to PET-positive sites. In patients with lymph node metastases outside the prostatic fossa and regional metastatic lymph nodes, choline PET/CT might influence radiation treatment planning by enabling extension of the target volume to lymphatic drainage sites with or without a boost to PET-positive lymph nodes. Further clinical randomized trials are required to assess treatment outcomes following choline-based biological radiation treatment planning in comparison with conventional radiation treatment planning. (orig.)

  17. Clinical Application of colored three-dimensional CT (3D-CT) for brain tumors using helical scanning CT (HES-CT)

    International Nuclear Information System (INIS)

    Ogura, Yuko; Katada, Kazuhiro; Fujisawa, Kazuhisa; Imai, Fumihiro; Kawase, Tsukasa; Kamei, Yoshifumi; Kanno, Tetsuo; Takeshita, Gen; Koga, Sukehiko

    1995-01-01

    We applied colored three-dimensional CT (colored 3D-CT) images to distinguish brain tumors from the surrounding vascular and bony structures using a work station system and helical scanning CT (HES-CT). CT scanners with a slip-ring system were employed (TCT-900S and X vigor). A slice thickness of 2 mm and bed speed of 2 mm/s were used. The volume of contrast medium injected was 60 to 70 ml. Four to 8 colors were used for the tissue segmentation on the workstation system (xtension) using the data transferred from HES-CT. Tissue segmentation succeeded on the colored 3D-CT images in all 13 cases. The relationship between the tumors and the surrounding structures were easily recognized. The technique was useful to simulate operative fields, because deep structures could be visualized by cutting and drilling the colored 3D-CT volumetric data. On the basis of our findings, we suggest that colored 3D-CT images should be used as a supplementary aid for preoperative simulation. (author)

  18. Demonstrations of AIDS-associated malignancies and infections at FDG PET-CT

    International Nuclear Information System (INIS)

    Liu, Y.

    2011-01-01

    HIV infection results in profound alterations of immunologic function that render the patient severely immunocompromised, and susceptible to malignancies and opportunistic infections. Three AIDS-defining malignancies include Kaposi's sarcoma (KS), non-Hodgkin's lymphoma (NHL) and invasive cervical cancer. In AIDS patients, KS is often aggressive and multifocal, with visceral involvement and widespread cutaneous and nodal spread; NHL is always high grade and often widely disseminated at the time of diagnosis with frequent involvement of extranodal sites; cervical cancer is invasive and has greater likelihood of progression and metastasis. Although there are very sparse systemic data available in the literature, limited studies has shown that fluorodeoxyglucose (FDG) positron emission tomography-computed tomography (PET-CT) is a valuable imaging technique in the diagnosis, staging, restaging and monitoring therapeutic response in these malignancies. In addition, a unique application of FDG PET/CT is the differentiation of cerebral lesions between lymphoma and toxoplasmosis in AIDS patients, which cannot be reliably achieved with either CT or MRI. HIV-associated opportunistic infections may involve different pathogens and multiple tissues, organs or systems. Some preliminary observations have revealed a promising role of FDG PET-CT in the diagnosis and identification of these infections such as tuberculosis, fever of unknown origin, pneumocystis pneumonia and candidiasis. However, it should be stressed that FDG PET-CT alone has no role in identifying the pathology of abnormalities. FDG PET-CT, at best, can localize the sites of abnormalities and impact on patient's management in clinical decision making. (author)

  19. Effects of Surface Epitope Coverage on the Sensitivity of Displacement Assays that Employ Modified Nanoparticles: Using Bisphenol A as a Model Analyte

    Directory of Open Access Journals (Sweden)

    Yang Lu

    2016-08-01

    Full Text Available With the ever-increasing use of nanoparticles in immunosensors, a fundamental study on the effect of epitope density is presented herein, with a small molecule epitope, on the performance of the displacement assay format in an enzyme-linked immunosorbent assay (ELISA. Thiolated bisphenol A (BPA functionalized gold nanoparticles (cysBPAv-AuNPs and specific anti-BPA antibodies are employed for this purpose. It is shown that the displacement of cysBPAv-AuNPs bound to the immobilized antibodies was influenced by both the avidity of bound cysBPAv-AuNPs and the concentration of free BPA to displace it. The importance of surface epitope density was that it changed the number of epitopes in close proximity to the antibody-binding site. This then influenced the avidity of cysBPAv-AuNPs bound to the immobilized antibody. Furthermore, the molar epitope concentration in an assay appears to affect the degree of antibody binding site saturation. Controlling surface epitope density of the functionalized nanoparticles and molar epitope concentration in an assay leads to a decrease of the concentration of free BPA required to displace the bound cysBPAv-AuNP, and hence better assay performance with regards to the D50 value and dynamic range in the displacement assay.

  20. Role of 18F-fluorodeoxyglucose PET/CT in Recurrent Ovary Cancer

    International Nuclear Information System (INIS)

    O, Joo Hyun; Yoo, Ie Ryung; Choi, Woo Hee; Lee, Won Hyoung; Kim, Sung Hoon; Chung, Soo Kyo

    2008-01-01

    To date, anatomical imaging modalities of the pelvis and tumor markers have been the mainstay of surveillance for recurrent ovary cancer. This study aimed to assess the role of 18F-FDG PET/CT in evaluation of ovary cancer recurrences, especially in comparison with enhanced CT and tumor marker CA 125. 73 patients who had PET/CT scan for restaging of confirmed ovary cancer, and additional imaging with enhanced CT of the pelvis within one month were included. CA 125 level was available in all patients. From the PET/CT images, maximum standard uptake values (SUVmax) of suspected recurrence sites were recorded. Confirmation was available through re-operation or biopsy in 26 cases, and clinical assessment with series of follow-up images in 47. PET/CT had 93% sensitivity and 88% specificity for detecting recurrent ovary cancer. Enhanced CT of pelvis had sensitivity and specificity of 83% and 88%, and CA 125 50% and 95%. PET/CT has higher sensitivity for detecting recurrent ovary cancer compared to enhanced CT though the differences were not significant. PET/CT has significantly higher sensitivity than CA 125. However, the three tests all agreed in only 43% of the recurrence cases, and recurrence should be suspected when any of the tests, especially PET/CT, show positive findings

  1. CT of pancreatitis

    International Nuclear Information System (INIS)

    Fukuda, Toshio

    1990-01-01

    One hundred and two cases of acute and chronic pancreatitis were studied by computed tomography. Fluid collection was detected by CT in 45 cases, and the common extrapancreatic sites of involvement included the lesser sac (13 cases), anterior pararenal space (9 cases), transverse mesocolon (7 cases) and posterior pararenal space (5 cases). Ten cases of spontaneous resolution of pancreatic pseudocysts were encountered. Cystojejunostomy was done on 6 patients. A 4-to-6-weeks time interval has been currently accepted as necessary for pseudocyst wall maturation. However, the surgery was not possible in two patients in this series since the cyst wall was too thin. It is considered that the time over 3 months is required for surgical anastomosis of the cyst to the gastrointestinal tract. Pancreatic abscess has become the most common cause of death from pancreatitis. In this series pancreatic abscess occurred in 8 patients. Gas collection in the pancreas was observed in only one patient. In the other patients, pseudocysts had become infected and converted to abscesses. The CT number of 4 infected pseudocysts was less than 15 HU. Thus, it was not possible to distinguish infected from noninfected pseudocysts by CT. The author studied 9 patients with focal inflammatory mass of the pancreas with histologically proved severe fibrosis. All masses were small. Angiography showed occlusion or marked stenosis of the splenic vein in 3 cases. The postcontract CT (after intravenous bolus injection) in 7 cases of focal inflammatory mass demonstrated almost equal enhanced effect of the mass as compared with the adjacent normal pancreatic parenchyma. This finding is considered to be useful in distinguishing inflammatory mass from pancreatic carcinoma. (author)

  2. Patient doses in CT examinations in Switzerland: Implementation of national diagnostic reference levels

    International Nuclear Information System (INIS)

    Treier, R.; Aroua, A.; Verdun, F. R.; Samara, E.; Stuessi, A.; Trueb, P. R.

    2010-01-01

    Diagnostic reference levels (DRLs) were established for 21 indication-based CT examinations for adults in Switzerland. One hundred and seventy-nine of 225 computed tomography (CT) scanners operated in hospitals and private radiology institutes were audited on-site and patient doses were collected. For each CT scanner, a correction factor was calculated expressing the deviation of the measured weighted computed tomography dose index (CTDI) to the nominal weighted CTDI as displayed on the workstation. Patient doses were corrected by this factor providing a realistic basis for establishing national DRLs. Results showed large variations in doses between different radiology departments in Switzerland, especially for examinations of the petrous bone, pelvis, lower limbs and heart. This indicates that the concept of DRLs has not yet been correctly applied for CT examinations in clinical routine. A close collaboration of all stakeholders is mandatory to assure an effective radiation protection of patients. On-site audits will be intensified to further establish the concept of DRLs in Switzerland. (authors)

  3. Role of plain radiography and CT angiography in the evaluation of obstructed total anomalous pulmonary venous connection

    International Nuclear Information System (INIS)

    Shen, Quanli; Pa, Mier; Hu, Xihong; Wang, Junbo

    2013-01-01

    Obstructed total anomalous pulmonary venous connection (TAPVC) is frequently misdiagnosed as pulmonary disease and without operative correction early death is common. It is important to make a correct diagnosis before surgery. The purpose of this study was to describe the chest radiographic features of obstructed TAPVC and compare CT angiography with transthoracic echocardiography in the evaluation of obstructed TAPVC. Eighteen children with obstructed TAPVC were assessed. Their clinical and imaging data were retrospectively reviewed. The characteristic radiographic findings were analyzed and compared with surgical results, and the diagnostic accuracy of CT angiography and transthoracic echocardiography was evaluated in terms of pulmonary venous drainage and obstruction detection. The common radiographic features included pulmonary venous congestion or edema or both (16 of 18 cases, 89%), and absence of cardiomegaly (12 of 18 cases, 67%). CT angiography correctly diagnosed TAPVC and clearly revealed the draining sites in all children (five with supracardiac TAPVC, three with cardiac TAPVC, eight with infracardiac TAPVC and two with mixed TAPVC). The diagnostic agreement between CT angiography and surgery was 100%. Transthoracic echocardiography only correctly revealed the draining sites in 11 children (5 with supracardiac TAPVC, 2 with cardiac TAPVC and 4 with infracardiac TAPVC). The diagnostic agreement between transthoracic echocardiography and surgery was 61%. The diagnostic accuracy of CT angiography was higher than that of transthoracic echocardiography (P = 0.0156). Thirty-four sites of obstruction were correctly detected by CT angiography (11 in the mediastinum, 1 at the diaphragmatic level, 9 below the diaphragm and 13 stenotic individual pulmonary veins in the lung). The diagnostic agreement between CT angiography and surgery was 92%. Transthoracic echocardiography only correctly detected 15 sites of obstruction (11 in the mediastinum, 1 at the

  4. Role of plain radiography and CT angiography in the evaluation of obstructed total anomalous pulmonary venous connection

    Energy Technology Data Exchange (ETDEWEB)

    Shen, Quanli; Pa, Mier; Hu, Xihong; Wang, Junbo [Children' s Hospital, Fudan University, Department of Radiology, Shanghai (China)

    2013-07-15

    Obstructed total anomalous pulmonary venous connection (TAPVC) is frequently misdiagnosed as pulmonary disease and without operative correction early death is common. It is important to make a correct diagnosis before surgery. The purpose of this study was to describe the chest radiographic features of obstructed TAPVC and compare CT angiography with transthoracic echocardiography in the evaluation of obstructed TAPVC. Eighteen children with obstructed TAPVC were assessed. Their clinical and imaging data were retrospectively reviewed. The characteristic radiographic findings were analyzed and compared with surgical results, and the diagnostic accuracy of CT angiography and transthoracic echocardiography was evaluated in terms of pulmonary venous drainage and obstruction detection. The common radiographic features included pulmonary venous congestion or edema or both (16 of 18 cases, 89%), and absence of cardiomegaly (12 of 18 cases, 67%). CT angiography correctly diagnosed TAPVC and clearly revealed the draining sites in all children (five with supracardiac TAPVC, three with cardiac TAPVC, eight with infracardiac TAPVC and two with mixed TAPVC). The diagnostic agreement between CT angiography and surgery was 100%. Transthoracic echocardiography only correctly revealed the draining sites in 11 children (5 with supracardiac TAPVC, 2 with cardiac TAPVC and 4 with infracardiac TAPVC). The diagnostic agreement between transthoracic echocardiography and surgery was 61%. The diagnostic accuracy of CT angiography was higher than that of transthoracic echocardiography (P = 0.0156). Thirty-four sites of obstruction were correctly detected by CT angiography (11 in the mediastinum, 1 at the diaphragmatic level, 9 below the diaphragm and 13 stenotic individual pulmonary veins in the lung). The diagnostic agreement between CT angiography and surgery was 92%. Transthoracic echocardiography only correctly detected 15 sites of obstruction (11 in the mediastinum, 1 at the

  5. Ground-penetrating radar observations for estimating the vertical displacement of rotational landslides

    OpenAIRE

    C. Lissak; O. Maquaire; J.-P. Malet; F. Lavigne; C. Virmoux; C. Gomez; R. Davidson

    2014-01-01

    The objective of this paper is to demonstrate the applicability of Ground Penetrating Radar (GPR) for monitoring the displacement of slow-moving landslides. GPR data is used to estimate the vertical movement of rotational slides in combination with other surveying techniques. The experimental site is located along the Normandy coast (North East France) here several rotational landslides are continuously affected by a seasonal kinematic pattern (low displacem...

  6. Ultra-low dose CT attenuation correction for PET/CT

    International Nuclear Information System (INIS)

    Xia Ting; Kinahan, Paul E; Alessio, Adam M; De Man, Bruno; Manjeshwar, Ravindra; Asma, Evren

    2012-01-01

    A challenge for positron emission tomography/computed tomography (PET/CT) quantitation is patient respiratory motion, which can cause an underestimation of lesion activity uptake and an overestimation of lesion volume. Several respiratory motion correction methods benefit from longer duration CT scans that are phase matched with PET scans. However, even with the currently available, lowest dose CT techniques, extended duration cine CT scans impart a substantially high radiation dose. This study evaluates methods designed to reduce CT radiation dose in PET/CT scanning. We investigated selected combinations of dose reduced acquisition and noise suppression methods that take advantage of the reduced requirement of CT for PET attenuation correction (AC). These include reducing CT tube current, optimizing CT tube voltage, adding filtration, CT sinogram smoothing and clipping. We explored the impact of these methods on PET quantitation via simulations on different digital phantoms. CT tube current can be reduced much lower for AC than that in low dose CT protocols. Spectra that are higher energy and narrower are generally more dose efficient with respect to PET image quality. Sinogram smoothing could be used to compensate for the increased noise and artifacts at radiation dose reduced CT images, which allows for a further reduction of CT dose with no penalty for PET image quantitation. When CT is not used for diagnostic and anatomical localization purposes, we showed that ultra-low dose CT for PET/CT is feasible. The significant dose reduction strategies proposed here could enable respiratory motion compensation methods that require extended duration CT scans and reduce radiation exposure in general for all PET/CT imaging. (paper)

  7. Ultra-low dose CT attenuation correction for PET/CT

    Science.gov (United States)

    Xia, Ting; Alessio, Adam M.; De Man, Bruno; Manjeshwar, Ravindra; Asma, Evren; Kinahan, Paul E.

    2012-01-01

    A challenge for PET/CT quantitation is patient respiratory motion, which can cause an underestimation of lesion activity uptake and an overestimation of lesion volume. Several respiratory motion correction methods benefit from longer duration CT scans that are phase matched with PET scans. However, even with the currently-available, lowest dose CT techniques, extended duration CINE CT scans impart a substantially high radiation dose. This study evaluates methods designed to reduce CT radiation dose in PET/CT scanning. Methods We investigated selected combinations of dose reduced acquisition and noise suppression methods that take advantage of the reduced requirement of CT for PET attenuation correction (AC). These include reducing CT tube current, optimizing CT tube voltage, adding filtration, CT sinogram smoothing and clipping. We explored the impact of these methods on PET quantitation via simulations on different digital phantoms. Results CT tube current can be reduced much lower for AC than that in low dose CT protocols. Spectra that are higher energy and narrower are generally more dose efficient with respect to PET image quality. Sinogram smoothing could be used to compensate for the increased noise and artifacts at radiation dose reduced CT images, which allows for a further reduction of CT dose with no penalty for PET image quantitation. Conclusion When CT is not used for diagnostic and anatomical localization purposes, we showed that ultra-low dose CT for PET/CT is feasible. The significant dose reduction strategies proposed here could enable respiratory motion compensation methods that require extended duration CT scans and reduce radiation exposure in general for all PET/CT imaging. PMID:22156174

  8. Project-induced displacement, secondary stressors, and health.

    Science.gov (United States)

    Cao, Yue; Hwang, Sean-Shong; Xi, Juan

    2012-04-01

    It has been estimated that about 15 million people are displaced by development projects around the world each year. Despite the magnitude of people affected, research on the health and other impacts of project-induced displacement is rare. This study extends existing knowledge by exploring the short-term health impact of a large scale population displacement resulting from China's Three Gorges Dam Project. The study is theoretically guided by the stress process model, but we supplement it with Cernea's impoverishment risks and reconstruction (IRR) model widely used in displacement literature. Our panel analysis indicates that the displacement is associated positively with relocatees' depression level, and negatively with their self-rated health measured against a control group. In addition, a path analysis suggests that displacement also affects depression and self-rated health indirectly by changing social integration, socioeconomic status, and community resources. The importance of social integration as a protective mechanism, a factor that has been overlooked in past studies of population displacement, is highlighted in this study. Published by Elsevier Ltd.

  9. Clinical application of gated CT and dynamic CT

    Energy Technology Data Exchange (ETDEWEB)

    Ishikawa, T; Oyama, Y; Ashida, H; Uji, T [Saint Marianna Univ., Kawasaki, Kanagawa (Japan). School of Medicine

    1980-03-01

    Gated CT and dynamic CT were outlined. Experiences of portal hypertension accompanied by venous mass in posterior mediastinum and the usefulness of dynamic CT for this disease were described. Gated CT of the heart could visualize intracardiac structures and morphological abnormalities by improving technique of post-data-aquisition correlation. Changes with time in CT images of normal kidneys were discussed on patients whose unilateral or bilateral kidneys were thought to be normal and who had received dynamic scan. Dynamic scan could visualize well blood circulation and mechanism of urine excretion in the kidney, which suggests a possibility of CT to detect not only morphological abnormalities but also functional disturbance of the kidney. The effectiveness of conventional CT study might be promoted in dynamic CT of the head.

  10. CT of petrou bone. Utility to cholesteatoma location. Study of 28 cases

    International Nuclear Information System (INIS)

    Ferrer, M.D.; Espinos, M.A.; Molina, A.; Martinez-Rodrigo, J.; Galant, J.

    1993-01-01

    Twenty-eight patients with cholesteatoma were studied preoperatively by means of CT petrous bone to determine the localization and extension of their lesion. All the patients underwent survey and the intraoperative findings were compared with those resulting from CT. The reading was carried out with no knowledge of the intraoperative data. The following results were obtained: localization of cholesteatoma in attic, antrum and posterior tympanic cavity had a sensitivity of 0.91 and a specificity of 0.57, with a Fisher's p value less than 0.0005. When the erosion produced by the cholesteatoma was studied in the different structures, the accuracy was greatest with the stape, the septum and prussak's space; the highest number of false negatives corresponded to the tympanic membrane. The false positives were produced in the assessment of the facial canal, tegmen tympani and the labyrinthine fistula. The reliability of CT was very high for the diagnosis of ossicular destruction and displacement of the small bones, as well as for the state of the mastoid cells and congenital variations. In conclusion, we point out the importance of performing a CT study prior to surgery for cholesteatoma due to its elevated sensitivity in locating the lesion, and we stress the value of the knowledge of the erosion of the different structures since it constitutes a guide for intraoperative exploration and assessment. (Author)

  11. CT image and clinical analysis of the term neonatal hypoxic-ischemic encephalopathy

    International Nuclear Information System (INIS)

    Zhan Zhigang; Zheng Keguo

    2006-01-01

    Objective: This is a retrospective investigation of 87 cases of perinatal HIE diagnosed in Junan hospital with literature review, made to improve the diagnosis of HIE, and provide objective information as well as the principle for clinical management and prognosis. Methods: In total 87 patients with HIE, including 52 males and 25 females, aged from 38 weeks to 42 weeks, underwent examination in 1 hour to 16 days after the delivery. There was natural labor in 39 cases, vacuum labor in 11 cases, forceps delivery in 9 cases, abdominal delivery in 6 cases. All the neonatal infants had a history of asphyxia on different levels. Results: CT scan showed diffuse or asymmetrical hypodense shadows with poorly-defined border, where the CT value measured between 10-18 HU, accompanying with the displacement or even absence of lateral ventricle. Subarachnoid hemorrhage (SAH) were found in 34 cases (39.5%), parenchyma hemorrhage in 24 cases (27.6%), intraventricular hemorrhage (IVH) in 15 cases (17.2%), and subdural hemorrhage in 5 cases (5.7%). Additionally, scalp turgidity was seen in 11 cases, and skull fracture in 4 cases as well. Conclusion: The CT scan shows the anoxicasphyxial lesions in the brain resulting from asphyxiation in neonatal, and the severity is rated with CT manifestation and brain edema, which provide objective guidance of the prognosis and the clinical management of HIE. (authors)

  12. Rhabdomyosarcoma of children in the head and neck : CT and MR finding

    International Nuclear Information System (INIS)

    Park, Byung Kwan; Kim, In One; Kim, Woo Sun; Han, Sang Wook; Kim, Hyun Beom; Yeon, Myung Mo

    1998-01-01

    The purpose of this study is to evaluate radiologic findings of rhabdomyosarcoma of children in the head and neck concerning the origin, morphologic characteristics, extent, and the route of intracranial extension on CT and MR. Twenty cases of pathologically proven rhabdomyosarcoma were analyzed. Fifteen CT scans (postcontrast CT (n=13), precontrast CT (n=2)) and eleven MR scans were obtained. Postcontrast MR scans were performed in the ten cases. Six cases had CT and MR scans. Nine cases had only CT scan and five had only MR scans. We retrospectively analyzed the origin, morphologic characteristics (attenuation, signal intensity, margin), extent,intracranial extension, route and clinical staging of rhabdomyosarcoma on CT and MR scans. Rhabdomyosarcoma of children in the head and neck tends to show relatively severe bony destruction of skull base and various intracranial extension routes can be helpful radiologic findings on the CT or MR scan although its CT density or signal intensity of MR was not specific. And it is peculiar that infratempral fossa was the most common site of origin of rhabdomyosarcoma. (author). 28 refs., 2 tabs., 5 figs

  13. Nursing care for patients with local recurrent rectal cancer after CT-guided 125I seed implantation therapy

    International Nuclear Information System (INIS)

    Yuan Li; Wei Fan; Ren Caifeng; Tu Mingmei; Qian Guixiang

    2010-01-01

    Objective: To discuss the nursing care strategy for patients with local recurrent rectal cancer who has been treated with CT-guided 125 I seed implantation therapy. Methods: Twenty patients with local recurrent rectal cancer received a series of nursing interventions, including comfort care and pain care. The clinical results were observed and analyzed. Results: The therapy was smoothly accomplished in all patients. The pain was remarkably relived and the anxiety was alleviated. No displacement of implanted 125 I seed occurred. Conclusion: For patients with local recurrent rectal cancer occurred after CT-guided 125 I seed implantation therapy, careful nursing can effectively relieve the pain and anxiety feeling,and the living quality can also be markedly improved. (authors)

  14. Investigation of Dose Minimisation Protocol for 18F-FDG PET-CT in the Management of Lymphoma Postchemotherapy Followup

    Directory of Open Access Journals (Sweden)

    L. I. Sonoda

    2012-01-01

    Full Text Available Introduction. 18F-FDG-PET-CT plays an important role in the management of lymphoma postchemotherapy followup. Some centres perform prechemotherapy baseline CT and postchemotherapy PETCT. With a concern of radiation burden, especially in young patients, this study aimed to assess if PETCT radiation dose could be reduced. Methods. Retrospective analysis of 100 lymphoma patients was performed to record sites of disease on prechemotherapy CT and postchemotherapy PETCT. The potential reduction in radiation and time achieved with PETCT limited to sites of known disease identified on prechemotherapy CT was calculated. Results. No FDG-uptake was seen in 72 cases. FDG uptake at known disease sites was seen in 24. Of the remaining 4, one had clinically significant pathology, a rectal adenocarcinoma. PETCT did not reveal any unexpected sites of lymphoma. Limiting PETCT to sites of known disease would have saved a mean radiation dose of 4 mSv (27.3%, with a mean time of 16 minutes. Conclusion. Our study suggests that young patients may benefit from reduced radiation by limiting PETCT to sites of known disease with low risk of missing significant pathology. However, in older patients, with increased incidence of asymptomatic synchronous malignancies, whole-body PETCT is advisable unless prechemotherapy PETCT has been performed.

  15. Emittance growth rates for displaced beams

    International Nuclear Information System (INIS)

    Anderson, O.A.

    1993-05-01

    Emittance growth rates have been previously analyzed for nonuniform beams in linear channels and for initially uniform mismatched beams in nonlinear channels. These studies were for centered beams. Additional emittance growth can arise in cases where the beam is initially displaced. The purpose of this study is to obtain growth rates for displaced beams. This work differs from studies involving random displacement of electrodes. Our analysis assumes instead that the focusing system is perfectly aligned but that the beam is initially displaced with respect to the equilibrium axis. If the focusing force is slightly nonlinear, we find a gradual transfer of the potential energy of beam displacement into kinetic energy associated with emittance growth. We present explicit results for the emittance growth distance as a function of the nonlinearity of the channel. These results will have practical importance for designers of accelerators and transport systems when setting realistic tolerances for initial beam alignment. These tolerances will depend on the nonlinearity and the length of the system

  16. Orthotopic neobladder reconstrution: postoperative CT appearance, complications and potential pitfalls

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Su Lim; Jung, Seung Eun; Im, Yeon Soo; Lee, Jae Mun; Lee, Ji Youl; Yoon, Moon Soo; Hahn, Seong Tai [The Catholic University of Korea College of Medicine, Seoul (Korea, Republic of)

    2003-08-01

    To evaluate the postoperative CT appearance, complications and potential pitfalls of radical cystectomy with orthotopic neobladder reconstruction. We examined 46 patients [43 men and 3 women aged 34-72 (mean, 56.7) years] who had undergone neobladder reconstruction (ileocolic neobladder in 25 patients and ileal-W neobladder in 21). The CT scans were assessed in terms of their depiction of normal anatomy, namely the shape, location and internal architecture of the neobladder, the location of bladder bases, and the ureteral course. Early and late complications were also assessed. The characteristics of ileocolic neobadder were a right-side location, a lobulated outer margin, interal projections due to haustra or plication, a base in the retropubis, and right-side insertion of both ureters. In contrast, the characteristics of an ileal-W neobladder were a central location, an ovoid shape, nodular thickening at the ureteral insertion site, internal projections due to plication, and a retropubic bladder base. Early complications included hematoma with abscess formation (n=2), and postoperative peritonitis (n=1), while late complications were hydronephrosis due to stricture ar the ureteral anastomotic site (n=16), tumor recurrence at this site (n=1), distal ureteral stone (n=1), mucus urinary retention (n=1), incisional hernia (n=2), tumor recurrence in the pelvic side wall (n=1), carcinomatosis peritonei (n=1), and liver metastasis (n=2). A knowledge of normal anatomic changes is essential for the accurate interpretation of CT scans. CT is a useful modality of the evaluation of postoperative change and the complications occurring in patients who have undergone radial cystectomy with othotopic neobladder reconstruction.

  17. Is Fibular Fracture Displacement Consistent with Tibiotalar Displacement?

    NARCIS (Netherlands)

    van den Bekerom, Michel P. J.; van Dijk, C. Niek

    2010-01-01

    We believed open reduction with internal fixation is required for supination-external rotation ankle fractures located at the level of the distal tibiofibular syndesmosis (Lauge-Hanssen SER II and Weber B) with 2 mm or more fibular fracture displacement. The rationale for surgery for these ankle

  18. Phenomenon of displacement in Arabic language

    Directory of Open Access Journals (Sweden)

    2015-09-01

    Full Text Available Displacement is one of the characteristics of language and common phenomena in the Arabic language. Not only is this phenomenon limited to Arabic poetry and prose, but it is also broadened, so we can see examples of this in the Qur'an. Because of this phenomenon extensively in Arabic literature and also because of its essence that leads to the transmission of the elements for the first visibility to the other visibility in the sentence and sometimes had to change the grammatical role of the words, its identify helps us in a better understanding of text and the correct translation of it and protects the reader from mistakes. This paper in the descriptive analytical approach tries studying of the phenomenon of the displacement in the Arabic language and bringing its instances in Arabic poetry and prose as well as verses contained in the Holy Quran, to show that through the types and characteristics in the Arabic language and to response to several questions, including: how important is the displacement and what is its types in rhetoric, and the reasons of the displacement, and etc... Of the most important results of this study may refer to the undeniable role of the displacement as a rhetorical method to better understanding of the texts including: one of the most important reasons of the displacement in the use of language is to improve speech verbally and morally, and violation of the standard language and create a poetic atmosphere, and the recognition of the occurrence of the phenomenon of displacement in the Arabic language that uphold different interpretations remote and estimates when faced with the displacement in the text and help us to understand it and etc...

  19. A Strange Case of Downward Displacement of a Deep Brain Stimulation Electrode 10 Years Following Implantation: The Gliding Movement of Snakes Theory.

    Science.gov (United States)

    Iacopino, Domenico Gerardo; Maugeri, Rosario; Giugno, Antonella; Giller, Cole A

    2015-08-01

    Despite the best efforts to ensure stereotactic precision, deep brain stimulation (DBS) electrodes can wander from their intended position after implantation. We report a case of downward electrode migration 10 years following successful implantation in a patient with Parkinson disease. A 53-year-old man with Parkinson disease underwent bilateral implantation of DBS electrodes connected to a subclavicular 2-channel pulse generator. The generator was replaced 7 years later, and a computed tomography (CT) scan confirmed the correct position of both leads. The patient developed a gradual worsening affecting his right side 3 years later, 10 years after the original implantation. A CT scan revealed displacement of the left electrode inferiorly into the pons. The new CT scans and the CT scans obtained immediately after the implantation were merged within a stereotactic planning workstation (Brainlab). Comparing the CT scans, the distal end of the electrode was in the same position, the proximal tip being significantly more inferior. The size and configuration of the coiled portions of the electrode had not changed. At implantation, the length was 27.7 cm; after 10 years, the length was 30.6 cm. These data suggests that the electrode had been stretched into its new position rather than pushed. Clinicians evaluating patients with a delayed worsening should be aware of this rare event. Copyright © 2015 Elsevier Inc. All rights reserved.

  20. Congenital external auditory canal atresia and stenosis: temporal bone CT findings

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Dong Hoon; Kim, Bum Soo; Jung, So Lyung; Kim, Young Joo; Chun, Ho Jong; Choi, Kyu Ho; Park, Shi Nae [College of Medicine, Catholic Univ. of Korea, Seoul (Korea, Republic of)

    2002-04-01

    To determine the computed tomographic (CT) findings of atresia and stenosis of the external auditory canal (EAC), and to describe associated abnormalities in surrounding structures. We retrospectively reviewed the axial and coronal CT images of the temporal bone in 15 patients (M:F=8:7;mean age, 15.8 years) with 16 cases of EAC atresia (unilateral n=11, bilateral n=1) and EAC stenosis (unilateral n=3). Associated abnormalities of the EAC, tympanic cavity, ossicles, mastoid air cells, eustachian tube, facial nerve course, mandibular condyle and condylar fossa, sigmoid sinus and jugular bulb, and the base of the middle cranial fossa were evaluated. Thirteen cases of bony EAC atresia (one bilateral), with an atretic bony plate, were noted, and one case of unilateral membranous atresia, in which a soft tissue the EAC. A unilateral lesion occurred more frequently on the right temporal bone (n=8, 73%). Associated abnormalities included a small tympanic cavity (n=8, 62%), decreased mastoid pneumatization (n=8, 62%), displacement of the mandibular condyle and the posterior wall of the condylar fossa (n=7, 54%), dilatation of the Eustachian tube (n=7, 54%), and inferior displacement of the temporal fossa base (n=8, 62%). Abnormalities of ossicles were noted in the malleolus (n=12, 92%), incus (n=10, 77%) and stapes (n=6, 46%). The course of the facial nerve was abnormal in four cases, and abnormality of the auditory canal was noted in one. Among three cases of EAC stenosis, ossicular aplasia was observed in one, and in another the location of the mandibular condyle and condylar fossa was abnormal. In the remaining case there was no associated abnormality. Atresia of the EAC is frequently accompanied by abnormalities of the middle ear cavity, ossicles, and adjacent structures other than the inner ear. For patients with atresia and stenosis of this canal, CT of the temporal bone is essentially helpful in evaluating these associated abnormalities.

  1. Earthquake related displacement fields near underground facilities

    International Nuclear Information System (INIS)

    Pratt, H.R.; Zandt, G.; Bouchon, M.

    1979-04-01

    Relative displacements of rock masses are evaluated in terms of geological evidence, seismological evidence, data from simulation experiments, and analytical predictive models. Numerical models have been developed to determine displacement fields as a function of depth, distance, and azimuth from an earthquake source. Computer calculations for several types of faults indicate that displacements decrease rapidly with distance from the fault, but that displacements can either increase or decrease as a function of depth depending on the type and geometry of the fault. For long shallow vertical strike-slip faults the displacement decreases markedly with depth. For square strike slip faults and for dip slip faults displacement does not decrease as markedly with depth. Geologic structure, material properties, and depth affect the seismic source spectrum. Amplification of the high frequencies of shear waves is larger by a factor of about 2 for layered geologic models than for an elastic half space

  2. Necrotizing fasciitis : plain radiographic and CT findings

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Chang Dae; Park, Jeong Hee; Jeon, Hae Jeong; Lim, Jong Nam; Heo, Tae Haeng; Park, Dong Rib [Konkuk Univ. College of Medicine, Seoul (Korea, Republic of)

    1996-11-01

    To evaluate the plain radiographic and CT findings of the necrotizing fasciitis. We retrospectively reviewed the radiologic findings of 4 cases with necrotizing fasciitis. Three cases were proven pathologically. We evaluated pattern and extent of the gas shadows in plain films. CT findings were analysed, with emphasis on : (a) gas pattern, (b) extent, (c) location and involved site, (d) associated focal abscess, and (e) swelling of the adjacent muscles. On plain radiographs, four cases showed streaky or mottled gas densities in the pelvis, three cases in the perineum, one case in the abdomen, and two cases in the thigh. On CT images, gas pattern was mottled and streaky appearance with swelling of the adjacent muscles. Gas shadows located in the extraperitoneal space in four cases, fascial layer in four cases, and subcutaneous layer in four cases. There were gas shadows in pelvic wall, perineum, abdominal wall, buttock, thigh, and scrotum. Focal low density lesion suggestive of focal abscess was not visualized. Plain radiography is useful for early diagnosis of the necrotizing fasciitis and CT is very useful for detection of precise location and extent of the disease. CT is also useful for differentiation of necrotizing fasciitis from focal abscess and cellulitis.

  3. Brain perfusion-CT in acute stroke patients

    International Nuclear Information System (INIS)

    Wintermark, M.

    2005-01-01

    The role of neuro-imaging in the evaluation of acute stroke has changed dramatically in the past decade. Previously, neuro-imaging was used in this setting to provide anatomic imaging that indicated the presence or absence of acute cerebral ischemia and excluded lesions that produce symptoms or signs mimicking those of stroke, such as hemorrhage and neoplasms. More recently, the introduction of thrombolysis has changed the goals of neuro-imaging from providing solely anatomic information to providing physiologic information that could help to determine which patients might benefit from therapy. In particular, significant emphasis has been placed on the delineation of the ischemic penumbra, also called tissue at risk. Modern CT survey, consisting of three indissociable elements: noncontrast CT (NCT) of course, perfusion-CT (PCT) and CT-angiography (CTA), fulfill all the requirements for hyper-acute stroke imaging. CTA can define the occlusion site, depict arterial dissection, grade collateral blood flow, and characterize atherosclerotic disease, whereas PCT accurately delineates the infarct core and the ischemic penumbra. CT offers a number of practical advantages over other cerebral perfusion imaging methods, including its wide availability. Using PCT and CTA to define new individualized strategies for acute reperfusion will allow more acute stroke patients to benefit from thrombolytic therapy. (orig.)

  4. Opioid binding site in EL-4 thymoma cell line

    International Nuclear Information System (INIS)

    Fiorica, E.; Spector, S.

    1988-01-01

    Using EL-4 thymoma cell-line we found a binding site similar to the k opioid receptor of the nervous system. The Scatchard analysis of the binding of [ 3 H] bremazocine indicated a single site with a K/sub D/ = 60 +/- 17 nM and Bmax = 2.7 +/- 0.8 pmols/10 6 cells. To characterize this binding site, competition studies were performed using selective compounds for the various opioid receptors. The k agonist U-50,488H was the most potent displacer of [ 3 H] bremazocine with an IC 50 value = 0.57μM. The two steroisomers levorphanol and dextrorphan showed the same affinity for this site. While morphine, [D-Pen 2 , D-Pen 5 ] enkephalin and β-endorphin failed to displace, except at very high concentrations, codeine demonstrated a IC 50 = 60μM, that was similar to naloxone. 32 references, 3 figures, 2 tables

  5. FDG avidity and PET/CT patterns in primary gastric lymphoma

    International Nuclear Information System (INIS)

    Radan, Lea; Fischer, Doron; Bar-Shalom, Rachel; Israel, Ora; Dann, Eldad J.; Epelbaum, Ron; Haim, Nissim; Gaitini, Diana

    2008-01-01

    The use of 18F-fluoro-deoxyglucose positron emission tomography/computed tomography (FDG-PET/CT) in primary gastric lymphoma (PGL) is challenging due to physiologic FDG activity in the stomach and variability in the degree of uptake in various histologic subtypes. This study assesses FDG avidity and PET/CT patterns in newly diagnosed PGL. Sixty-two PET/CT studies of newly diagnosed PGL were reviewed (24 low-grade mucosa-associated lymphoid tissue [MALT], 38 aggressive non-Hodgkin's lymphoma [AGNHL]). FDG avidity, patterns (focal/diffuse), and intensity (visually vs. the liver and SUVmax) were assessed and compared to 27 controls. Gastric CT abnormalities and extragastric sites were recorded. Gastric FDG uptake was found in 55/62 (89%) PGL (71% MALT vs. 100% AGNHL, p < 0.001) and 63% controls. A diffuse pattern was found in 60% PGL (76% MALT vs. 53% AGNHL, p = NS) and 47% controls. FDG uptake higher than liver was found in 82% PGL (58% MALT vs. 97% AGNHL, p < 0.05) and 63% controls. SUVmax in FDG-avid PGLs was 15.3 ± 11.7 (5.4 ± 2.9 MALT vs. 19.7 ± 11.5 AGNHL, p < 0.001) and 4.6 ± 1.4 in controls. CT abnormalities were found in 79% PGL (thickening, n = 49; ulcerations, n = 22). Extra-gastric FDG-avid sites were seen in none of MALT, but 61% of AGNHL (nodal, n = 18; nodal and extranodal, n 5). FDG avidity was present in 89% of PGLs, including all patients with AGNHL but only 71% of MALT. FDG uptake can be differentiated, in particular in AGNHL-PGL, from physiologic tracer activity by intensity but not by pattern. Extragastric foci on PET and structural CT abnormalities are additional parameters that can improve PET/CT assessment of PGL. Defining FDG avidity and PET/CT patterns in AGNHL and a subgroup of MALT-PGL before treatment may be important for further monitoring therapy response. (orig.)

  6. FDG avidity and PET/CT patterns in primary gastric lymphoma

    Energy Technology Data Exchange (ETDEWEB)

    Radan, Lea [Rambam Health Care Campus, Department of Nuclear Medicine, Haifa (Israel); Fischer, Doron [Rambam Health Care Campus, Department of Diagnostic Imaging, Haifa (Israel); Bar-Shalom, Rachel; Israel, Ora [Technion - Israel Institute of Technology, Department of Nuclear Medicine, Rambam Health Care Campus and R. and B. Rappaport School of Medicine, Haifa (Israel); Dann, Eldad J. [Technion - Israel Institute of Technology, Department of Hematology, Rambam Health Care Campus, and R. and B. Rappaport School of Medicine, Haifa (Israel); Epelbaum, Ron; Haim, Nissim [Technion - Israel Institute of Technology, Department of Oncology, Rambam Health Care Campus, and R. and B. Rappaport School of Medicine, Haifa (Israel); Gaitini, Diana [Rambam Health Care Campus, and R. and B. Rappaport School of Medicine, Technion - Israel Institute of Technology, Department of Diagnostic Imaging, Haifa (Israel)

    2008-08-15

    The use of 18F-fluoro-deoxyglucose positron emission tomography/computed tomography (FDG-PET/CT) in primary gastric lymphoma (PGL) is challenging due to physiologic FDG activity in the stomach and variability in the degree of uptake in various histologic subtypes. This study assesses FDG avidity and PET/CT patterns in newly diagnosed PGL. Sixty-two PET/CT studies of newly diagnosed PGL were reviewed (24 low-grade mucosa-associated lymphoid tissue [MALT], 38 aggressive non-Hodgkin's lymphoma [AGNHL]). FDG avidity, patterns (focal/diffuse), and intensity (visually vs. the liver and SUVmax) were assessed and compared to 27 controls. Gastric CT abnormalities and extragastric sites were recorded. Gastric FDG uptake was found in 55/62 (89%) PGL (71% MALT vs. 100% AGNHL, p < 0.001) and 63% controls. A diffuse pattern was found in 60% PGL (76% MALT vs. 53% AGNHL, p = NS) and 47% controls. FDG uptake higher than liver was found in 82% PGL (58% MALT vs. 97% AGNHL, p < 0.05) and 63% controls. SUVmax in FDG-avid PGLs was 15.3 {+-} 11.7 (5.4 {+-} 2.9 MALT vs. 19.7 {+-} 11.5 AGNHL, p < 0.001) and 4.6 {+-} 1.4 in controls. CT abnormalities were found in 79% PGL (thickening, n = 49; ulcerations, n = 22). Extra-gastric FDG-avid sites were seen in none of MALT, but 61% of AGNHL (nodal, n = 18; nodal and extranodal, n = 5). FDG avidity was present in 89% of PGLs, including all patients with AGNHL but only 71% of MALT. FDG uptake can be differentiated, in particular in AGNHL-PGL, from physiologic tracer activity by intensity but not by pattern. Extragastric foci on PET and structural CT abnormalities are additional parameters that can improve PET/CT assessment of PGL. Defining FDG avidity and PET/CT patterns in AGNHL and a subgroup of MALT-PGL before treatment may be important for further monitoring therapy response. (orig.)

  7. Traumatic thoracic injury: the role of Multidetector-row CT

    International Nuclear Information System (INIS)

    Lim, Se Kyong; Shin, Kyung Sook; Kim, Ha Young; Sung, Jae Kyu; Jung, Hyun Yong; Noh, Seong Moo; Song, Kyu Sang; Cho, June Sik

    2006-01-01

    Hyperplastic polyps are common gastric lesions that are characterized by nonneoplastic epithelial hyperplasia. However, to our knowledge, there are no reports of a hyperplastic polyp arising from an endoscopic mucosectomy site of early gastric cancer. We describe the CT findings with a histopathology correlation in a case of a hyperplastic polyp arising from a mucosectomy site that mimicked polypoid gastric cancer

  8. Traumatic thoracic injury: the role of Multidetector-row CT

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Se Kyong; Shin, Kyung Sook; Kim, Ha Young; Sung, Jae Kyu; Jung, Hyun Yong; Noh, Seong Moo; Song, Kyu Sang; Cho, June Sik [Chungnam National University School of Medicine, Daejeon (Korea, Republic of)

    2006-05-15

    Hyperplastic polyps are common gastric lesions that are characterized by nonneoplastic epithelial hyperplasia. However, to our knowledge, there are no reports of a hyperplastic polyp arising from an endoscopic mucosectomy site of early gastric cancer. We describe the CT findings with a histopathology correlation in a case of a hyperplastic polyp arising from a mucosectomy site that mimicked polypoid gastric cancer.

  9. Role of CT/PET in predicting nodal disease in head and neck cancers

    International Nuclear Information System (INIS)

    Singham, S.; Iyer, G.; Clark, J.

    2009-01-01

    Full text:Introduction: Pre-treatment evaluation of the presence of cervical nodal metastases is important in head and neck cancers and has major prognostic implications. In this study, we aim to determine the accuracy of CT/PET as a tool for identifying such metastases. Methods: All patients from Royal Prince Alfred and Liverpool Hospitals, who underwent CT/PET for any cancer arising from the head and neck, and who underwent subsequent surgery (which included a neck dissection) within 8 weeks of the CT/PET were included. Nodal staging was undertaken by utilising imaging-based nodal classification, and comparison with pathologic data from the surgical specimen was made. PET was considered positive if the SUV was greater than 2. Results: We identified 111 patients from the above criteria. 80 of such patients were treated for squamous cell carcinoma (SCC). CT/PET identified unsuspected metastatic disease in 6 patients. Correlation of CT/PET findings and the presence of disease at the primary site: sensitivity: 98%, specificity: 93%, positive predictive value (PPV): 98% and negative predictive value (NPV): 93%. Correlating CT/PET findings with the presence of nodal disease at any level: sensitivity: 95%, specificity: 88%, PPV: 95% and NPV: 88%. CT/PET was anatomically accurate in predicting the site of metastases in 62/74 (84%). Conclusion: PET is accurate in predicting both presence of nodal metastases and the level of involvement. CT/PET should be undertaken as a pre-operative tool to assist in planning the extent of surgery required in head and neck cancers.

  10. Mass-forming chronic pancreatitis : CT and ERCP features

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Dong Jin; Ha, Hyun Kwon; Lee, Yong Suk; Lee, Jin Hwa; Kim, Pyo Nyun; Lee, Moon Gyu; Auh, Yong Ho [Asan Medical Center, Ulsan Univ. College of Medicine, Ulsan (Korea, Republic of)

    1999-11-01

    To describe the CT and ERCP findings of mass-forming chronic pancreatitis. CT and ERCP features were assessed in 13 patients suffering from mass-forming chronic pancreatitis. Diagnosis was on the basis of surgery (n=5), percutaneous needle biopsy (n=3), and clinical follow-up (n=5). Contrast-enhanced CT was available for all patients : five underwent dynamic study and ERCP was performed in 12. On CT and ERCP, both groups were evaluated with regard to the presence and degree of pancreatic ductal dilatation (greater or less than 50 % of total gland width), double duct sign, enhancement pattern, pancreatic parenchymal calcification (site and distribution pattern), mass identification, the direction of infiltration, pancreatic parenchymal atrophy, configuration at the site of obstruction in the pancreatic and common bile duct, lymphadenopathy, vascular encasement, and vascular engorgement or increased collateral vessels in the peripancreatic space. Seven of 13 patients had suffered chronic alcoholism. Serum CA19-9 levels were normal in all patients except one. Common CT and ERCP findings of mass-forming chronic pancreatitis included pancreatic duct dilatation (92.3%), double duct sign (69.2%), inhomogeneous enhancement of the mass (69.2%), and the presence of calcification (61.5%). Patterns of pancreatic duct dilation were irregular in five patients (38.4%) and smooth in three (23.1%). In all patients, duct dilatation was less than 50% of total gland width. Enhancement patterns of the pancreatic mass were inhomogeneous (69.2%), a nonenhancing low attenuation mass (15.3%), and homogeneous enhancement (15.3%). Configuration at the site of obstruction in the pancreatic duct was abrupt termination in two patients (15.4%) and smooth termination in two (15.4%). The common bile duct teminated abruptly in three patients (23.1%), and in four (30.8%) smooth narrowing was abserved. Common findings of mass-forming chronic pancreatitis were duct dilatation of less than 50% of total

  11. Mass-forming chronic pancreatitis : CT and ERCP features

    International Nuclear Information System (INIS)

    Jung, Dong Jin; Ha, Hyun Kwon; Lee, Yong Suk; Lee, Jin Hwa; Kim, Pyo Nyun; Lee, Moon Gyu; Auh, Yong Ho

    1999-01-01

    To describe the CT and ERCP findings of mass-forming chronic pancreatitis. CT and ERCP features were assessed in 13 patients suffering from mass-forming chronic pancreatitis. Diagnosis was on the basis of surgery (n=5), percutaneous needle biopsy (n=3), and clinical follow-up (n=5). Contrast-enhanced CT was available for all patients : five underwent dynamic study and ERCP was performed in 12. On CT and ERCP, both groups were evaluated with regard to the presence and degree of pancreatic ductal dilatation (greater or less than 50 % of total gland width), double duct sign, enhancement pattern, pancreatic parenchymal calcification (site and distribution pattern), mass identification, the direction of infiltration, pancreatic parenchymal atrophy, configuration at the site of obstruction in the pancreatic and common bile duct, lymphadenopathy, vascular encasement, and vascular engorgement or increased collateral vessels in the peripancreatic space. Seven of 13 patients had suffered chronic alcoholism. Serum CA19-9 levels were normal in all patients except one. Common CT and ERCP findings of mass-forming chronic pancreatitis included pancreatic duct dilatation (92.3%), double duct sign (69.2%), inhomogeneous enhancement of the mass (69.2%), and the presence of calcification (61.5%). Patterns of pancreatic duct dilation were irregular in five patients (38.4%) and smooth in three (23.1%). In all patients, duct dilatation was less than 50% of total gland width. Enhancement patterns of the pancreatic mass were inhomogeneous (69.2%), a nonenhancing low attenuation mass (15.3%), and homogeneous enhancement (15.3%). Configuration at the site of obstruction in the pancreatic duct was abrupt termination in two patients (15.4%) and smooth termination in two (15.4%). The common bile duct teminated abruptly in three patients (23.1%), and in four (30.8%) smooth narrowing was abserved. Common findings of mass-forming chronic pancreatitis were duct dilatation of less than 50% of total

  12. Deploying Difference: Security Threat Narratives and State Displacement from Protected Areas

    Directory of Open Access Journals (Sweden)

    Elizabeth Lunstrum

    2018-01-01

    Full Text Available State actors are increasingly treating protected areas as sites of security threats and policing resident communities as though they are the cause of this insecurity. This is translating into community eviction from protected areas that is authorised by security concerns and logics and hence not merely conservation concerns. We ground this claim by drawing upon empirical work from two borderland conservation areas: Mozambique's Limpopo National Park (LNP and Guatemala's Maya Biosphere Reserve (MBR. In both cases, we show how these security-provoked evictions are authorised by the mobilisation of interlocking axes of difference that articulate notions of territorial trespass with that of a racialised enemy. Rather than a new problem or phenomena, we show how these axes are rooted in prior histories of state actors rendering racialised subjects dangerous, Cold War histories in both cases and a longer colonial history with the LNP. We also show how standing behind these evictions is the nation-state and its practices of protected area territorialisation. From here, we illustrate how the rationale behind displacement from protected areas matters, as evictions become more difficult to contest once they are authorised by security considerations. The cases, however, differ in one key respect. While displacement from the LNP is an instance of conservation-induced displacement (CID, although one re-worked by security considerations, eviction from the MBR is motivated more centrally by security concerns yet takes advantage of protected area legislation. The study hence offers insight into a growing literature on conservation-security encounters and into different articulations of conservation, security, and displacement.

  13. Displacement of specific serotonin and lysergic acid diethylamide binding by Ergalgin, a new antiserotonin drug

    International Nuclear Information System (INIS)

    Oelszner, W.

    1980-01-01

    [ 3 H]-serotonin and [ 3 H]-lysergic acid diethylamide (LSD) bind with a high affinity, Ksub(D) = 12 nM and 6 nM, respectively, to distinct receptors of rat caudate membranes in vitro. Displacement experiments with unlabeled serotonin and LSD support the hypothesis of serotonin receptors existing in an agonist and antagonist state. Methysergide and Ergalgin display quite similar potenties in displacing [ 3 H]-serontonin and [ 3 H]-LSD from their specific binding sites (Ksub(i) = 46.7 and 53.4 nM; 22.3 and 36.5 nM, respectively). Contrary to pharmacological findings these binding results are in favour of mixed agonist/antagonist properties of these compounds. (author)

  14. Role of FDG PET/CT in Diagnostic Evaluation of Granulocytic Sarcomas: A Series of 12 Patients.

    Science.gov (United States)

    Chandra, Piyush; Dhake, Sanket; Purandare, Nilendu; Agrawal, Archi; Shah, Sneha; Rangarajan, Venkatesh

    2017-01-01

    Granulocytic sarcoma (GS) is a rare extramedullary manifestation in patients with acute myeloid leukemia (AML), which can precede the diagnosis or occur in the posttreatment setting. Unlike its established role in other hematological malignancies like Hodgkin's on non-Hodgkin's disease, the exact role of positron emission tomography/computed tomography (PET/CT) in AML with or without GS remains to be defined. We retrospectively reviewed PET/CT scans of 12 patients with histologically proven GS. Marrow examination of these patients identified nine patients with isolated GS (without existent leukemia) and three patients with coexistent leukemia. PET/CT accurately identified all clinically evident GS in all 12 patients at initial staging and at follow-up with tumors, showing moderate to high 2-deoxy-2-fluoro-D-glucose uptake. Coexistent marrow disease was seen on PET/CT in three patients, which was confirmed on histopathology. In the same patients, PET/CT also detected additional sites of extramedullary disease in 66.6% (n = 8), which was either clinically occult or not evident on routine CT. PET/CT appears to be a highly sensitive imaging modality in diagnostic evaluation of GS. The most important indication of using PET/CT in these cases is to identify additional sites of clinically occult extramedullary disease, which can potentially impact treatment decisions and outcomes.

  15. Detection of distant metastasis and prognostic prediction of recurrent salivary gland carcinomas using 18 F-FDG PET/CT.

    Science.gov (United States)

    Lee, S H; Roh, J-L; Kim, J S; Lee, J H; Choi, S-H; Nam, S Y; Kim, S Y

    2018-04-24

    To compare the diagnostic accuracy of 18 F-FDG PET/CT and conventional contrast-enhanced CT for the re-staging of recurrent salivary gland carcinoma (SGC). This study included 58 consecutive patients who underwent recurrent SGCs after definitive treatment. The recurrences were evaluated by 18 F-FDG PET/CT and contrast-enhanced CT of the neck and chest. McNemar's test was used to compare the diagnostic accuracy of 18 F-FDG PET/CT with standard neck and chest CT imaging, and a Cox proportional hazards model was used to assess the prognostic value of PET/CT. Of 58 patients with recurrent SGCs, 17 (29%) had a local recurrence, 17 (29%) had a regional recurrence, and 38 (66%) had a distant metastasis, with these classifications showing overlap. The sensitivity and accuracy of 18 F-FDG PET/CT for the detection of distant metastases were significantly higher than those of CT (P 0.1). The 18 F-FDG PET/CT-positive findings at distant sites were predictors of poor progression-free and overall survival outcome (all P PET/CT is a more effective method than CT for detecting distant site recurrences of SGC. This may lead to prognostic prediction for recurrent SGCs. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  16. CT diagnostic criteria of branchial cysts

    Energy Technology Data Exchange (ETDEWEB)

    Jend, H.H.; Jend-Rossmann, I.; Techentin, E.C.

    1984-09-01

    Although well known, the morphology of branchial cysts has not been sufficiently presented in CT literature. In the present case report, diagnostic criteria are given, such as typical site of occurrence, ductal extension towards the supratonsillar fossa, and cystic, but occasionally soft tissue density. Differential diagnosis is given for cases which cannot be classified according to these criteria.

  17. CT findings of palpable neck masses in children

    International Nuclear Information System (INIS)

    Park, Chan Sup; Chung, Won Mo; Seok, Eul Hye; Suh, Chang Hae; Chung, Won Kyun

    1994-01-01

    We performed this study to assess the value of CT in the differential diagnosis of palpable neck masses in children. We retrospectively reviewed the CT scans of the palpable neck masses in 30 children. The masses were proved histopathologically and classified into cystic, solid, and inflammatory mass and their CT findings were analyzed. Twelve cases were cystic masses, 4 were solid masses, and 14 were inflammatory lesions. Cystic masses included cystic lymphangiomas (n=6), branchial cleft cysts (n=3), thyroglossal duct cysts (n=2), and ranula (n=1). Cystic lymphangiomas showed insinuating appearances into adjacent structures and 4 cases occurred in the posterior cervical space. All branchial cleft cysts were round cystic masses with smooth wall and displaced the submandibular gland anteriorly and the sternocleidomastoid muscle posteriorly. Two thyroglossal duct cysts occurred centrally adjacent to the hyoid bone and 1 ranula in the submental area. Solid masses were juvenile hemangioma, pleomorphic adenoma in submandibular gland, neurilemmoma, and fibromatosis colli. Juvenile hemangioma showed well-enhancing mass with indistinct margin and the other solid masses had well-defined margin with their characteristic location. Inflammatory lesions were abscess (n=4), deep neck infections with lymphadenopathy (n=4), submandibular gland inflammation (n=3), and tuberculous lymphadenitis (n=3) and they showed strand-like enhancement in adjacent subcutaneous tissues. Tuberculous lymphadenitis had multiple lymph node enlargement with internal low attenuation areas and showed less surrounding strand-like enhancement than suppurative lymphadenopathies. Most neck masses in infants and children were of congenital or inflammatory origin. CT is useful for the evaluation of the child presenting with a neck mass, because it can differentiate various forms of neck masses and is able to reveal the relationship of the masses to the adjacent structures with their characteristic location

  18. CT findings of palpable neck masses in children

    Energy Technology Data Exchange (ETDEWEB)

    Park, Chan Sup; Chung, Won Mo; Seok, Eul Hye; Suh, Chang Hae; Chung, Won Kyun [College of Medicine, Inha University, Incheon (Korea, Republic of)

    1994-12-15

    We performed this study to assess the value of CT in the differential diagnosis of palpable neck masses in children. We retrospectively reviewed the CT scans of the palpable neck masses in 30 children. The masses were proved histopathologically and classified into cystic, solid, and inflammatory mass and their CT findings were analyzed. Twelve cases were cystic masses, 4 were solid masses, and 14 were inflammatory lesions. Cystic masses included cystic lymphangiomas (n=6), branchial cleft cysts (n=3), thyroglossal duct cysts (n=2), and ranula (n=1). Cystic lymphangiomas showed insinuating appearances into adjacent structures and 4 cases occurred in the posterior cervical space. All branchial cleft cysts were round cystic masses with smooth wall and displaced the submandibular gland anteriorly and the sternocleidomastoid muscle posteriorly. Two thyroglossal duct cysts occurred centrally adjacent to the hyoid bone and 1 ranula in the submental area. Solid masses were juvenile hemangioma, pleomorphic adenoma in submandibular gland, neurilemmoma, and fibromatosis colli. Juvenile hemangioma showed well-enhancing mass with indistinct margin and the other solid masses had well-defined margin with their characteristic location. Inflammatory lesions were abscess (n=4), deep neck infections with lymphadenopathy (n=4), submandibular gland inflammation (n=3), and tuberculous lymphadenitis (n=3) and they showed strand-like enhancement in adjacent subcutaneous tissues. Tuberculous lymphadenitis had multiple lymph node enlargement with internal low attenuation areas and showed less surrounding strand-like enhancement than suppurative lymphadenopathies. Most neck masses in infants and children were of congenital or inflammatory origin. CT is useful for the evaluation of the child presenting with a neck mass, because it can differentiate various forms of neck masses and is able to reveal the relationship of the masses to the adjacent structures with their characteristic location.

  19. SOCIAL CAPITAL IN INVOLUNTARY DISPLACEMENT AND RESETTLEMENT

    Directory of Open Access Journals (Sweden)

    Melissa Quetulio-Navarra

    2013-07-01

    Full Text Available Social capital is often seen as a substitute for lack of other types of capital amongpoor people. Because of the recognized applicability of the social capital conceptand its correlation with the different dimensions of poverty, it has been used inevaluating the adaptation and integration of involuntarily displaced individualsinto their new environment. This paper presents insights based on a review of thefindings of studies that looked into the role of social capital in conflict- anddevelopment-induced displacement contexts. Althoughboth types of displace-ments are involuntary or forced in nature, they differ in terms of the role of socialcapital regarding its main sources, the formation pattern and its determinants.Social capital studies in forced resettlement appear to be relatively small innumber and are heavily concentrated on first worldcountries and conflict- anddevelopment-induced displacements. The conduct of similar studies in developingcountries and in a disaster-induced resettlement context, the third type ofinvoluntary displacement, should generate new and relevant findings regardingthe role of social capital in resettlement communities.

  20. War, forced displacement and growth in Laotian adults.

    Science.gov (United States)

    Clarkin, Patrick F

    2012-01-01

    Evidence from several populations suggests that war negatively impacts civilian nutrition, physical growth and overall health. This effect is often enduring or permanent, particularly if experienced early in life. To assess whether the number of lifetime displacement experiences and being displaced in infancy were associated with adult height, sitting height, leg length and the sitting height ratio. Retrospective questionnaires on displacement and resettlement experiences and anthropometric data were collected from a sample of Laotian adult refugees (ethnic Hmong and Lao; n = 365). All were born in Laos or Thailand and had resettled in French Guiana or the US. Many had been displaced several times by military conflict in Laos. In bivariate analyses, being displaced in infancy and the number of lifetime displacement experiences one had were negatively associated with final adult height and leg length in both sexes. The association was stronger in females, particularly Hmong females. There was no significant association between total displacement experiences and the sitting height ratio. In multiple regression analyses, linear growth in males was negatively associated with being displaced in infancy; in females, the number of lifetime displacement experiences was a significant predictor. Forced displacement from war appears to have a lasting effect on final adult height, sitting height and leg length, although not necessarily on the sitting height ratio in this sample.

  1. A new classification for cervical vertebral injuries: influence of CT

    International Nuclear Information System (INIS)

    Daffner, R.H.; Brown, R.R.; Goldberg, A.L.

    2000-01-01

    Objective. Computed tomography (CT) has been demonstrated to be superior to radiography in identifying cervical vertebral injuries. However, many of these injuries may not be clinically significant, and require only minimal symptomatic and supportive treatment. It is therefore imperative that radiologists and spine surgeons have criteria for distinguishing between those injuries requiring surgical stabilization and those that do not. The authors propose a new classification of cervical vertebral injuries into two categories: major and minor.Design and patients. A data base, acquired on 1052 separate cervical injuries in 879 patients seen between 1983 and 1998, was reviewed. Four categories of injury based on mechanism [hyperflexion (four variants), hyperextension (two variants), rotary (two variants), and axial compression (five variants)] were identified. ''Major'' injuries are defined as having either radiographic or CT evidence of instability with or without associated localized or central neurologic findings, or have the potential to produce the latter. ''Minor'' injuries have no radiographic and/or CT evidence of instability, are not associated with neurologic findings, and have no potential to cause the latter.Results and conclusions. Cervical injury should be classified as ''major'' if the following radiographic and/or CT criteria are present: displacement of more than 2 mm in any plane, wide vertebral body in any plane, wide interspinous/interlaminar space, wide facet joints, disrupted posterior vertebral body line, wide disc space, vertebral burst, locked or perched facets (unilateral or bilateral), ''hanged man'' fracture of C2, dens fracture, and type III occipital condyle fracture. All other types of fractures may be considered ''minor''. (orig.)

  2. Evaluation of hepatic alveolar echinococcosis with multi-slices spiral CT

    International Nuclear Information System (INIS)

    Liu Wenya; Lou Jianru; Xing Yan; Wang Jing; Wang Haitao

    2005-01-01

    Objective: To analyze the multi-slices spiral CT (MSCT) findings of hepatic alveolar echinococcosis (HAE), and to evaluate the value of MSCT for diagnosis of HAE. Methods: Twenty-six cases with HAE were scanning by MSCT. The raw data were transmitted to advanced workstation for reconstruction imaging. Correlated studies were made between the CT features and pathology or other imaging results. Results: Altogether 28 lesions were detected. They all revealed as heterogeneous hypodense mass with ill-defined boundary in plain CT but were easily being distinguished from surrounding parenchyma after contrast medium injection. Characteristics of the lesions include different amount of calcification (26/26), liquefied necrosis in center area (20/26), peripheral lacunae or alveolar signs (15/26 ), compensatory hypertrophy of healthy hepatic part (18/26) and the retraction in the involved hepatic lobe or segment (12/26). The lesions that located at or extended to hepatic hilum caused dilatation of intra-hepatic biliary ducts (9/26), splenomegaly (12/26 ), and ascites (1/26). MSCT angiography (CTA) depicted signs of abnormalities of hepatic vessels such as compression, displacement, encasement and occlusion. Compared with findings of operation, the sensitivity, specificity and positive prediction value of CTA for evaluating the hepatic artery system disorders were 88%, 96% and 93%, respectively; and for portal venous system were 95%, 100% and 95%, respectively; while for hepatic venous system were 96%, 86% and 96%, respectively. Conclusion: MSCT is able to comprehensive display the CT features and vessels complication of HAE. It provides reliable imaging for both accuracy diagnosis and proper treatment of the disease. (authors)

  3. Seasonal and multi-year surface displacements measured by DInSAR in a High Arctic permafrost environment

    Science.gov (United States)

    Rudy, Ashley C. A.; Lamoureux, Scott F.; Treitz, Paul; Short, Naomi; Brisco, Brian

    2018-02-01

    Arctic landscapes undergo seasonal and long-term changes as the active layer thaws and freezes, which can result in localized or irregular subsidence leading to the formation of thermokarst terrain. Differential Interferometric Synthetic Aperture Radar (DInSAR) is a technique capable of measuring ground surface displacements resulting from thawing permafrost at centimetre precision and is quickly gaining acceptance as a means of measuring ground displacement in permafrost regions. Using RADARSAT-2 stacked DInSAR data from 2013 and 2015 we determined the magnitude and patterns of land surface change in a continuous permafrost environment. At our study site situated in the Canadian High Arctic, DInSAR seasonal ground displacement patterns were consistent with field observations of permafrost degradation. As expected, many DInSAR values are close to the detection threshold (i.e., 1 cm) and therefore do not indicate significant change; however, DInSAR seasonal ground displacement patterns aligned well with climatological and soil conditions and offer geomorphological insight into subsurface processes in permafrost environments. While our dataset is limited to two years of data representing a three-year time period, the displacements derived from DInSAR provide insight into permafrost change in a High Arctic environment and demonstrate that DInSAR is an applicable tool for understanding environmental change in remote permafrost regions.

  4. The interaction of substituted benzamides with brain benzodiazepine binding sites in vitro.

    OpenAIRE

    Horton, R. W.; Lowther, S.; Chivers, J.; Jenner, P.; Marsden, C. D.; Testa, B.

    1988-01-01

    1. The interaction of substituted benzamides with brain benzodiazepine (BDZ) binding sites was examined by their ability to displace [3H]-flunitrazepam ([3H]-FNM) from specific binding sites in bovine cortical membranes in vitro. 2. Clebopride, Delagrange 2674, Delagrange 2335 and BRL 20627 displayed concentration-dependent displacement of [3H]-FNM with IC50 values of 73 nM, 132 nM, 7.7 microM and 5.9 microM, respectively. Other substituted benzamides including metoclopramide, sulpiride, tiap...

  5. Evaluation of an automated deformable image matching method for quantifying lung motion in respiration-correlated CT images

    International Nuclear Information System (INIS)

    Pevsner, A.; Davis, B.; Joshi, S.; Hertanto, A.; Mechalakos, J.; Yorke, E.; Rosenzweig, K.; Nehmeh, S.; Erdi, Y.E.; Humm, J.L.; Larson, S.; Ling, C.C.; Mageras, G.S.

    2006-01-01

    We have evaluated an automated registration procedure for predicting tumor and lung deformation based on CT images of the thorax obtained at different respiration phases. The method uses a viscous fluid model of tissue deformation to map voxels from one CT dataset to another. To validate the deformable matching algorithm we used a respiration-correlated CT protocol to acquire images at different phases of the respiratory cycle for six patients with nonsmall cell lung carcinoma. The position and shape of the deformable gross tumor volumes (GTV) at the end-inhale (EI) phase predicted by the algorithm was compared to those drawn by four observers. To minimize interobserver differences, all observers used the contours drawn by a single observer at end-exhale (EE) phase as a guideline to outline GTV contours at EI. The differences between model-predicted and observer-drawn GTV surfaces at EI, as well as differences between structures delineated by observers at EI (interobserver variations) were evaluated using a contour comparison algorithm written for this purpose, which determined the distance between the two surfaces along different directions. The mean and 90% confidence interval for model-predicted versus observer-drawn GTV surface differences over all patients and all directions were 2.6 and 5.1 mm, respectively, whereas the mean and 90% confidence interval for interobserver differences were 2.1 and 3.7 mm. We have also evaluated the algorithm's ability to predict normal tissue deformations by examining the three-dimensional (3-D) vector displacement of 41 landmarks placed by each observer at bronchial and vascular branch points in the lung between the EE and EI image sets (mean and 90% confidence interval displacements of 11.7 and 25.1 mm, respectively). The mean and 90% confidence interval discrepancy between model-predicted and observer-determined landmark displacements over all patients were 2.9 and 7.3 mm, whereas interobserver discrepancies were 2.8 and 6

  6. Displacement Ventilation

    DEFF Research Database (Denmark)

    Bjørn, Erik; Mattsson, Magnus; Sandberg, Mats

    Full-scale experiments were made in a displacement ventilated room with two breathing thermal manikins to study the effect of movements and breathing on the vertical contaminant distribution, and on the personal exposure of occupants. Concentrations were measured with tracer gas equipment...

  7. Spread-F occurrences and relationships with foF2 and h'F at low- and mid-latitudes in China

    Science.gov (United States)

    Wang, Ning; Guo, Lixin; Zhao, Zhenwei; Ding, Zonghua; Lin, Leke

    2018-04-01

    Ionospheric irregularities are an important phenomenon in scientific studies and applications of radio-wave propagation. Spread-F echoes in ionograms are a type of high-frequency band irregularities that include frequency spread-F (FSF), range spread-F (RSF), and mixed spread-F (MSF) events. In this study, we obtained spread-F data from four ionosondes at low- and mid-latitudes near the 120°E chain in China during the 23rd solar cycle. We used these data to investigate spread-F occurrence percentages and variations with local time, season, latitude, and solar activity. The four ionosondes were located at Haikou (HK) (20°N, 110.34°E), Guangzhou (GZ) (23.14°N, 113.36°E), Beijing (BJ) (40.11°N, 116.28°E), and Changchun (CC) (43.84°N, 125.28°E). We also present possible correlations between spread-Fs and other ionospheric parameters, such as the critical frequency of the F2-layer (foF2) and the virtual height of the bottom-side F-layer (h'F). In particular, we investigated the possible threshold of the foF2 affecting the FSF and the relationship between the h'F and the RSF. The main conclusions are as follows: (a) the FSF occurrence percentages were anti-correlated with solar activity at all four sites; meanwhile, RSF occurrence rates increased with the increase in solar activity at HK, but not at the other three sites; (b) FSF occurrence rates were larger at the mid-latitudes than expected, while FSFs occurred more often after midnight; (c) the highest FSF occurrence rates mostly appeared during the summer months, while RSFs occurred mostly in the equinoctial months of 2000-2002 at HK and GZ; (d) a lower foF2 was suitable for FSF events; nevertheless, h'F and RSF occurrences satisfied the parabolic relationship; (e) the foF2 thresholds for FSFs were 15, 14, 7.6, and 7.8 MHz at HK, GZ, BJ, and CC, respectively. The h'Fs occurring between 240 and 290 km were more favorable for RSF occurrences. These results are important for understanding ionospheric

  8. Role of {sup 18F} FDG PET/CT, {sup 123I} MIBG SPECT, and CT in Restaging patients Affected by Malignant Pheochromocytoma

    Energy Technology Data Exchange (ETDEWEB)

    Cantalamessa, Antonio; Caobelli, Antonio; Vavassori, Francesca [Habilita Istituto Clinico, Bergamo (Italy); Caobelli, Federico [Univ. of Brescia, Brescia (Italy); Paghera, Barbara [Spedali Civili, Brescia (Italy)

    2011-06-15

    Pheochromocytoma (PH) is a rare catecholamine secreting tumor that arises from chromaffin tissue within the adrenal medulla and extra adrenal sites; commonly it is sporadic, and malignant PH accounts for about 10% of all cases. Several imaging modalities have been used for the diagnosis and staging og this tumor: functional imaging using radio labelled metaiodobenzylguanidine and, more recently, {sup 18F} fluorodeoxyglucose positron emission tomography ({sup 18F} FDG PET/CT), which offers substantial sensitivity and specificity to correctly detect metastatic PH and helps to identify patients suitable for treatment with radiopharmaceuticals. The aim of our study was to compare CT, {sup 18F} FDG PET/CT, and {sup 123I} metaiodobenzylguanidine single photon emission tomography ({sup 123I} MIBG SPECT) as feasible methods to restage patients diagnosed histologically with PH. We retrospectively evaluated 38 patients (27 females and 11 males; mean age: 44{+-}15 years) with malignant PH documented histologically after surgical intervention. These patients underwent CT, {sup 18F} FDG PET/CT, and {sup 123I} MIBG SPECT. {sup 18F} FDG PET/CT showed positive results for neoplastic tissue in 33/38 patients (86.8%) and negative in 5/38 (13.2%), in concordance with CT alone. {sup 123I} MIBG SPECT was positive in 30/38 patients (78.9%) and negative in 8/38 (21.1%). No differences in lesion numbers were found between {sup 18F} FDG PET/CT and {sup 123I} MIBG SPECT. {sup 18F} FDG PET/CT could more accurately restage patients with PH than CT and {sup 123I} MIBG SPECT, also in the absence of a staging study.

  9. Computed tomographic evaluation of the proximal femur: A predictive classification in displaced femoral neck fracture management

    Directory of Open Access Journals (Sweden)

    Narender Kumar Magu

    2014-01-01

    Full Text Available Background: Femoral neck fracture is truly an enigma due to the high incidence of avascular necrosis and nonunion. Different methods have been described to determine the size of the femoral head fragment, as a small head has been said to be associated with poor outcome and nonunion due to inadequate implant purchase in the proximal fragment. These methods were two dimensional and were affected by radiography techniques, therefore did not determine true head size. Computed tomography (CT is an important option to measure true head size as images can be obtained in three dimensions. Henceforth, we subjected patients to CT scan of hip in cases with displaced fracture neck of femur. The study aims to define the term "small head or inadequate size femoral head" objectively for its prognostic significance. Materials and Methods: 70 cases of displaced femoral neck fractures underwent CT scan preoperatively for proximal femoral geometric measurements of both hips. Dual energy X-ray absorptiometry scan was done in all cases. Patients were treated with either intertrochanteric osteotomy or lag screw osteosynthesis based on the size of the head fragment on plain radiographs. Results: The average femoral head fragment volume was 57 cu cm (range 28.3-84.91 cu cm; standard deviation 14 cu cm. Proximal fragment volume of >43 cu cm was termed adequate size (type I and of ≤43 cu cm as small femoral head (type II. Fractures which united (n = 54 had a relatively large average head size (59 cu cm when compared to fractures that did not (n = 16, which had a small average head size (49 cu cm and this difference was statistically significant. In type I fractures union rate was comparable in both osteotomy and lag screw groups (P > 0.05. Lag screw fixation failed invariably, while osteotomy showed good results in type II fractures (P < 0.05. Conclusion: Computed tomography scan of the proximal femur is advisable for measuring true size of head fragment. An objective

  10. The usefulness of levin tube inserted drip infusion spiral CT: comparison with conventional method in subtotal gastrectomy patients

    International Nuclear Information System (INIS)

    Park, Young Jin; Kim, Young Hwan; Yoon, Jung Hee; Cha, Soon Joo; Kim, Jeong Sook; Kim, Sung Rok; Hur, Gham; Rhim, Hyun Chul

    1998-01-01

    The purpose of this study is to access the usefulness of newly designed Levin tube inserted drip infusion spiral CT for the evaluation of remnant stomach and anastomosis site in patients who have undergone subtotal gastrectomy for stomach cancer. A new technique named Levin tube inserted drip infusion spiral CT was used to prospectively study 23 patients. A 16Fr Levin tube was inserted into the remnant stomach; 500 ml of tap water was drip infused just before CT scanning and an additional 500 ml of water was infused during IV contrast injection. Water was infused by gravity, using a water bottle suspended at a height of 90 cm (Group A). The 31 patients who underwent conventional spiral CT scanning immediately after the divided ingestion of 900 ml diluted gastrografin were selected as a control group (Group B). The anatomic delineation of the anastomosis site was graded by two radiologists as excellent (3), good(2), fair (1) or poor (0). To evaluate the degree of distension, the maximal diameters of remnant stomach and the anastomosis site, and the thickness of the stomach wall, were also measured. In patients who had undergone subtobal gastrectomy, Levin tube inserted drip infusion spiral CT showed excellent anatomic delineation of the site of anastomosis and remnant stomach. We found that because it increases the distension of remnant stomach and the anastomosis site, this technique is effective for the evaluation of postoperative stomach. (author). 10 refs., 2 tabs., 3 figs

  11. Tracking speckle displacement by double Kalman filtering

    Institute of Scientific and Technical Information of China (English)

    Donghui Li; Li Guo

    2006-01-01

    @@ A tracking technique using two sequentially-connected Kalman filter for tracking laser speckle displacement is presented. One Kalman filter tracks temporal speckle displacement, while another Kalman filter tracks spatial speckle displacement. The temporal Kalman filter provides a prior for the spatial Kalman filter, and the spatial Kalman filter provides measurements for the temporal Kalman filter. The contribution of a prior to estimations of the spatial Kalman filter is analyzed. An optical analysis system was set up to verify the double-Kalman-filter tracker's ability of tracking laser speckle's constant displacement.

  12. Role of {sup 18}F-fluorodeoxyglucose PET/CT in Recurrent Ovary Cancer

    Energy Technology Data Exchange (ETDEWEB)

    O, Joo Hyun; Yoo, Ie Ryung; Choi, Woo Hee; Lee, Won Hyoung; Kim, Sung Hoon; Chung, Soo Kyo [The Catholic University of Korea, Seoul (Korea, Republic of)

    2008-06-15

    To date, anatomical imaging modalities of the pelvis and tumor markers have been the mainstay of surveillance for recurrent ovary cancer. This study aimed to assess the role of 18F-FDG PET/CT in evaluation of ovary cancer recurrences, especially in comparison with enhanced CT and tumor marker CA 125. 73 patients who had PET/CT scan for restaging of confirmed ovary cancer, and additional imaging with enhanced CT of the pelvis within one month were included. CA 125 level was available in all patients. From the PET/CT images, maximum standard uptake values (SUVmax) of suspected recurrence sites were recorded. Confirmation was available through re-operation or biopsy in 26 cases, and clinical assessment with series of follow-up images in 47. PET/CT had 93% sensitivity and 88% specificity for detecting recurrent ovary cancer. Enhanced CT of pelvis had sensitivity and specificity of 83% and 88%, and CA 125 50% and 95%. PET/CT has higher sensitivity for detecting recurrent ovary cancer compared to enhanced CT though the differences were not significant. PET/CT has significantly higher sensitivity than CA 125. However, the three tests all agreed in only 43% of the recurrence cases, and recurrence should be suspected when any of the tests, especially PET/CT, show positive findings.

  13. Fast shading correction for cone beam CT in radiation therapy via sparse sampling on planning CT.

    Science.gov (United States)

    Shi, Linxi; Tsui, Tiffany; Wei, Jikun; Zhu, Lei

    2017-05-01

    The image quality of cone beam computed tomography (CBCT) is limited by severe shading artifacts, hindering its quantitative applications in radiation therapy. In this work, we propose an image-domain shading correction method using planning CT (pCT) as prior information which is highly adaptive to clinical environment. We propose to perform shading correction via sparse sampling on pCT. The method starts with a coarse mapping between the first-pass CBCT images obtained from the Varian TrueBeam system and the pCT. The scatter correction method embedded in the Varian commercial software removes some image errors but the CBCT images still contain severe shading artifacts. The difference images between the mapped pCT and the CBCT are considered as shading errors, but only sparse shading samples are selected for correction using empirical constraints to avoid carrying over false information from pCT. A Fourier-Transform-based technique, referred to as local filtration, is proposed to efficiently process the sparse data for effective shading correction. The performance of the proposed method is evaluated on one anthropomorphic pelvis phantom and 17 patients, who were scheduled for radiation therapy. (The codes of the proposed method and sample data can be downloaded from https://sites.google.com/view/linxicbct) RESULTS: The proposed shading correction substantially improves the CBCT image quality on both the phantom and the patients to a level close to that of the pCT images. On the phantom, the spatial nonuniformity (SNU) difference between CBCT and pCT is reduced from 74 to 1 HU. The root of mean square difference of SNU between CBCT and pCT is reduced from 83 to 10 HU on the pelvis patients, and from 101 to 12 HU on the thorax patients. The robustness of the proposed shading correction is fully investigated with simulated registration errors between CBCT and pCT on the phantom and mis-registration on patients. The sparse sampling scheme of our method successfully

  14. Description of patellar movement by 3D parameters obtained from dynamic CT acquisition

    Science.gov (United States)

    de Sá Rebelo, Marina; Moreno, Ramon Alfredo; Gobbi, Riccardo Gomes; Camanho, Gilberto Luis; de Ávila, Luiz Francisco Rodrigues; Demange, Marco Kawamura; Pecora, Jose Ricardo; Gutierrez, Marco Antonio

    2014-03-01

    The patellofemoral joint is critical in the biomechanics of the knee. The patellofemoral instability is one condition that generates pain, functional impairment and often requires surgery as part of orthopedic treatment. The analysis of the patellofemoral dynamics has been performed by several medical image modalities. The clinical parameters assessed are mainly based on 2D measurements, such as the patellar tilt angle and the lateral shift among others. Besides, the acquisition protocols are mostly performed with the leg laid static at fixed angles. The use of helical multi slice CT scanner can allow the capture and display of the joint's movement performed actively by the patient. However, the orthopedic applications of this scanner have not yet been standardized or widespread. In this work we present a method to evaluate the biomechanics of the patellofemoral joint during active contraction using multi slice CT images. This approach can greatly improve the analysis of patellar instability by displaying the physiology during muscle contraction. The movement was evaluated by computing its 3D displacements and rotations from different knee angles. The first processing step registered the images in both angles based on the femuŕs position. The transformation matrix of the patella from the images was then calculated, which provided the rotations and translations performed by the patella from its position in the first image to its position in the second image. Analysis of these parameters for all frames provided real 3D information about the patellar displacement.

  15. Detection of Esophageal Fiducial Marker Displacement During Radiation Therapy With a 2-dimensional On-board Imager: Analysis of Internal Margin for Esophageal Cancer

    International Nuclear Information System (INIS)

    Fukada, Junichi; Hanada, Takashi; Kawaguchi, Osamu; Ohashi, Toshio; Takeuchi, Hiroya; Kitagawa, Yuko; Seki, Satoshi; Shiraishi, Yutaka; Ogata, Haruhiko; Shigematsu, Naoyuki

    2013-01-01

    Purpose: To quantify the interfraction displacement of esophageal fiducial markers for primary esophageal cancer radiation therapy. Methods and Materials: Orthogonal 2-dimensional (2D) matching records fused to vertebrae were analyzed in clinically staged T1/2N0 esophageal cancer patients undergoing endoscopic clipping as fiducial metal markers. Displacement of the markers between the digitally reconstructed radiographs and on-board kilovoltage images during radiation therapy was analyzed according to direction and esophageal site. Results: Forty-four patients, with 81 markers (10 proximal, 42 middle, and 29 distal), underwent 367 2D matching sessions during radiation therapy. The mean (SD) absolute marker displacement was 0.26 (0.30) cm in the right–left (RL), 0.50 (0.39) cm in the superior–inferior (SI), and 0.24 (0.21) cm in the anterior–posterior (AP) direction. Displacement was significantly larger in the SI than in the RL and AP directions (P<.0001). In the SI direction, mean absolute displacements of the distal, middle, and proximal esophagus were 0.67 (0.45) cm, 0.42 (0.32) cm, and 0.36 (0.30) cm, respectively. Distal esophagus displacement was significantly larger than those of the middle and proximal esophagus (P<.0001). The estimated internal margin to cover 95% of the cases was 0.75 cm in the RL and AP directions. In the SI direction, the margin was 1.25 cm for the proximal and middle esophagus and 1.75 cm for the distal esophagus. Conclusions: The magnitude of interfraction displacement of esophageal clips was larger in the SI direction, particularly in the distal esophagus, but substantial displacement was observed in other directions and at other esophageal sites. It is practical to take estimated movements into account with internal margins, even if vertebrae-based 2D matching is performed

  16. Displaced epithelium after liposuction for gynecomastia.

    Science.gov (United States)

    McLaughlin, Cristina S; Petrey, Chris; Grant, Shawn; Ransdell, Jill S; Reynolds, Carol

    2011-08-01

    The authors describe the case of a 36-year-old man with gynecomastia who was previously treated with liposuction of the breast for cosmetic purposes. Histologic examination of a subsequent excisional biopsy revealed nests of displaced epithelial cells in adipose tissue. Epithelial cell displacement is a well-known risk of core needle biopsies and fine-needle aspirations of breast lesions. However, to the authors' knowledge, epithelial displacement in gynecomastia after liposuction, mimicking invasive ductal carcinoma, has not previously been reported.

  17. Opioid binding site in EL-4 thymoma cell line

    Energy Technology Data Exchange (ETDEWEB)

    Fiorica, E.; Spector, S.

    1988-01-01

    Using EL-4 thymoma cell-line we found a binding site similar to the k opioid receptor of the nervous system. The Scatchard analysis of the binding of (/sup 3/H) bremazocine indicated a single site with a K/sub D/ = 60 +/- 17 nM and Bmax = 2.7 +/- 0.8 pmols/10/sup 6/ cells. To characterize this binding site, competition studies were performed using selective compounds for the various opioid receptors. The k agonist U-50,488H was the most potent displacer of (/sup 3/H) bremazocine with an IC/sub 50/ value = 0.57..mu..M. The two steroisomers levorphanol and dextrorphan showed the same affinity for this site. While morphine, (D-Pen/sup 2/, D-Pen/sup 5/) enkephalin and ..beta..-endorphin failed to displace, except at very high concentrations, codeine demonstrated a IC/sub 50/ = 60..mu..M, that was similar to naloxone. 32 references, 3 figures, 2 tables.

  18. Water displacement mercury pump

    Science.gov (United States)

    Nielsen, M.G.

    1984-04-20

    A water displacement mercury pump has a fluid inlet conduit and diffuser, a valve, a pressure cannister, and a fluid outlet conduit. The valve has a valve head which seats in an opening in the cannister. The entire assembly is readily insertable into a process vessel which produces mercury as a product. As the mercury settles, it flows into the opening in the cannister displacing lighter material. When the valve is in a closed position, the pressure cannister is sealed except for the fluid inlet conduit and the fluid outlet conduit. Introduction of a lighter fluid into the cannister will act to displace a heavier fluid from the cannister via the fluid outlet conduit. The entire pump assembly penetrates only a top wall of the process vessel, and not the sides or the bottom wall of the process vessel. This insures a leak-proof environment and is especially suitable for processing of hazardous materials.

  19. CT findings of peritoneal carcinomatosis

    International Nuclear Information System (INIS)

    Kim, Eun Sook; Park, Mi Sook; Cho, On Koo; Koh, Byung Hee; Kim, Soon Yong

    1989-01-01

    CT findings in 137 patients with peritoneal cacinomatosis were reviewed to determine the CT signs of peritoneal malignancy. CT of the 20 liver cirrhosis and 17 tuberculous peritonitis were also reviewed to define the differential point between benign and malignant peritoneal change. The results were as follows. 1. The most common primary malignancy encountered in peritoneal carcinomatosis was stomach Ca.(50.4%), followed by pancreas Ca, hepatoma, colon Ca. and ovarian Ca. 2. Ascites was the most common CT feature of peritoneal malignancy, present in 99 cases (72.3%). The amount of ascites was voluminous, grade III in 70% of cases and showed high density ascites with average 23 Hounsfield units. 3. Greater omentum involvement was noted in 88 patients, peritoneum in 71 patients and mesentery in 65% patients. There was no correlation of the primary malignancy type with the incidence or pattern of the above mentioned site. 4. Bowel wall thickenings were observed in 51 patients, among which transverse colon was most frequently involved. 5. Mean attenuation value of ascites in liver cirrhosis was 10.7 HU, which was much lower than that of peritoneal carcinomatosis. 6. Even though intraperitoneal findings in Tbc. Peritonitis showed tendency of relatively small amount of ascites with more predominant mesenteric change, but, the findings of high density ascites, change of peritoneum and omentum etc. were very similar to those of peritoneal carcinomatosis. Therefore, based on only intraperitoneal change, differential diagnosis between them was difficult. 7. False negatives in CT diagnosis of peritoneal carcinomatosis occurred in 7 cases. There were tiny nodular changes in intraperitoneal cavity without ascites on operative findings

  20. The usefulness of brain MRI and CT in the clinical practice of epilepsia

    Energy Technology Data Exchange (ETDEWEB)

    Horita, Hideki [Jikei Univ., Komae, Tokyo (Japan). Daisan Hospital; Maekawa, Kihei

    1995-09-01

    This study was conducted to clarify the usefulness of brain MRI and CT in the clinical practice of epilepsy. The subjects were 100 epileptic child patients (average age, 13.2{+-}8.2 years) who underwent brain MRI, including 93 patients who also underwent brain CT. Twenty-two abnormal findings were obtained by MRI and 25 by CT. Thirty-nine patients who had complications such as mental retardation, cerebral palsy, or the overlapping disorders showed abnormal findings in a significantly high incidence. No significant correlations existed between the presence or absence of abnormal findings and the disease course after seizures. Patients with symptomatic localization-related epilepsies or cryptogenic and symptomatic generalized epilepsies showed abnormal findings in a significantly high incidence and unfavorable disease course after seizures. In 10 of 28 patients who showed abnormal findings, the abnormal finding site on images were correlated to the focus site on electroencephalograms. In conclusion, brain MRI and CT are essential in the clinical practice of epilepsy, however, we should notice the limitation of these methods. (Y.S.).

  1. The usefulness of brain MRI and CT in the clinical practice of epilepsia

    International Nuclear Information System (INIS)

    Horita, Hideki; Maekawa, Kihei.

    1995-01-01

    This study was conducted to clarify the usefulness of brain MRI and CT in the clinical practice of epilepsy. The subjects were 100 epileptic child patients (average age, 13.2±8.2 years) who underwent brain MRI, including 93 patients who also underwent brain CT. Twenty-two abnormal findings were obtained by MRI and 25 by CT. Thirty-nine patients who had complications such as mental retardation, cerebral palsy, or the overlapping disorders showed abnormal findings in a significantly high incidence. No significant correlations existed between the presence or absence of abnormal findings and the disease course after seizures. Patients with symptomatic localization-related epilepsies or cryptogenic and symptomatic generalized epilepsies showed abnormal findings in a significantly high incidence and unfavorable disease course after seizures. In 10 of 28 patients who showed abnormal findings, the abnormal finding site on images were correlated to the focus site on electroencephalograms. In conclusion, brain MRI and CT are essential in the clinical practice of epilepsy, however, we should notice the limitation of these methods. (Y.S.)

  2. Diagnosis of cancer of the tongue and oral floor using plain CT

    International Nuclear Information System (INIS)

    Ariji, Eiichiro; Kanda, Shigenobu

    1988-01-01

    CT images of 18 patients, diagnosed squamous cell carcinomas of the tongue or oral floor, were analyzed to assess the clinical importance of plain CT for primary sites. All cases were scanned on Somatom DR (Siemens) at the Department of Dental Radiology, Kyushu University Dental Hospital from 1985 to 1988. Results were as follows : 1, As descriptions of primary tumors mainly depended on their size in soft tissue, plain CT was useful only for advanced cases (T3, T4). 2, For cancer of the oral floor and advanced cases of cancer of the tongue, plain CT was useful to evaluate the bone invasion, especially in cases of lingual cortex of the anterior mandible. (author)

  3. The role of {sup 18}F-FDG PET/CT in the detection of osteosarcoma recurrence

    Energy Technology Data Exchange (ETDEWEB)

    Angelini, Andrea; Trovarelli, Giulia; Ruggieri, Pietro [University of Padova, Department of Orthopedics and Orthopedic Oncology, Padova (Italy); Ceci, Francesco; Castellucci, Paolo; Graziani, Tiziano; Polverari, Giulia; Fanti, Stefano [University of Bologna, Service of Nuclear Medicine, S.Orsola-Malpighi Hospital, Bologna (Italy); Palmerini, Emanuela; Ferrari, Stefano [Istituto Ortopedico Rizzoli, Department of Chemotherapy, Bologna (Italy)

    2017-09-15

    The aim of this study was to investigate the diagnostic accuracy of {sup 18}F-FDG-PET/CT in osteosarcoma patients suspicious for disease recurrence after adequate surgical therapy. Inclusion criteria were: a) adequate surgical treatment for proven osteosarcoma and documented complete remission after therapy; b) {sup 18}F-FDG-PET/CT performed during follow-up for clinical/diagnostic suspicion of relapse; c) new surgical treatment with excision of the suspected lesions; d) histological validation of {sup 18}F-FDG-PET/CT findings. Thirty-seven patients matching all inclusion criteria were retrospectively enrolled (20 men and 17 female). Primary surgical treatment consists of resection (31 cases) or amputation (six cases). {sup 18}F-FDG-PET/CT performance was assessed with a per-patient and per-site evaluation of sensitivity, specificity, accuracy, positive predicting value (PPV), and negative predicting value (NPV). The sites of relapse were classified as local, lung, lymphnodes (LNs), and distant (other skeletal segments and/or distant soft tissue). The disease-free survival (DFS) and the overall survival (OS) after 18F-FDG PET/CT were evaluated. {sup 18}F-FDG-PET/CT was positive in 89.2% (33/37) of patients. Local uptake only was observed in 35.1% patients (13/37); lung uptake only in 18.9% (7/37); distant uptake only in 2.7% (1/37) case; multiple sites of uptake in 32.4% (12/37). Histology resulted positive in 92% (34/37) of patients. A total of 51 pathologic lesions were evaluated (22 local relapse, 11 lung metastasis, 10 metastatic LNs, eight distant metastatic lesions). On a per-patient analysis {sup 18}F-FDG-PET/CT showed a sensitivity, specificity, accuracy, PPV, and NPV of 91%, 75%, 89%, 97%, 50%. On a per-site analysis the performance for local relapse was 96%, 100%, 97%, 100%, 93%, while for lung relapse detection was 80%, 100%, 92%, 100%, 88%. The mean follow-up after {sup 18}F-FDG-PET/CT was 21.5 months. At the last follow-up, 19% (7/37) of patients were

  4. Prolonged displacement may compromise resilience in Eritrean mothers.

    Science.gov (United States)

    Almedom, Astier; Tesfamichael, Berhe; Mohammed, Zein; Mascie-Taylor, Nick; Muller, Jocelyn; Alemu, Zemui

    2005-12-01

    to assess the impact of prolonged displacement on the resilience of Eritrean mothers. an adapted SOC scale (short form) was administered. Complementary qualitative data were gathered from study participants' spontaneous reactions to and commentaries on the SOC scale. Displaced women's SOC scores were significantly less than those of the non-displaced: Mean = 54.84; SD = 6.48 in internally displaced person (IDP) camps, compared to non-displaced urban and rural/pastoralist: Mean = 48. 94, SD = 11.99; t = 3.831, p urban (non-displaced). Rural but traditionally mobile (pastoralist or transhumant) communities scored more or less the same as the urban non-displaced--i.e., significantly higher than those in IDP camps (p urban and pastoralist/transhumant groups were similar, while women in IDP camps were lower scoring--RR = .268, p < .001. The implications of these findings for health policy are critical. It is incumbent on the international health institutions including the World Health Organization and regional as well as local players to address the plight of internally displaced women, their families and communities in Eritrea and other places of dire conditions such as, for example Darfur in the Sudan.

  5. Cochlear pathology: CT and MRI findings

    International Nuclear Information System (INIS)

    Martinez, Manuel; Bruno, Claudio; Martin, Eduardo; Canale, Nancy; De Luca, Laura; Spina, Juan C. h

    2002-01-01

    The authors present a retrospective analysis of 50 patients with perceptive hearing loss. The neuro physiological work-up (evoked potentials, audiometric tests and otoemissions) identified the cochlea as the site of origin of the hearing loss. The imaging studies (high resolution CT and MR, including 3D volumes) showed petrous bone trauma (n=5) infections (bacterial or viral origin) (n=12) otosclerosis (n=8), Paget disease (n=3), and labyrinthine neurinomas (n=2). The other 20 cases showed development-linked disorders (Mitchel's, Mondini, Scheibe, Alexander, and hypoplasia of the cochlear canal). Imaging with CT and MR can identify in detail the structural abnormality affecting the cochlea and occasionally the immediate peri-cochlear region (otic capsule); the affected portion of the cochlea may thus be determined. (author)

  6. CT diagnostic criteria of branchial cysts

    International Nuclear Information System (INIS)

    Jend, H.H.; Jend-Rossmann, I.; Techentin, E.C.

    1984-01-01

    Although well known, the morphology of branchial cysts has not been sufficiently presented in CT literature. In the present case report, diagnostic criteria are given, such as typical site of occurrence, ductal extension towards the supratonsillar fossa, and cystic, but occasionally soft tissue density. Differential diagnosis is given for cases which cannot be classified according to these criteria. (orig.) [de

  7. Utility of CT-guided abdominal aspiration procedures

    International Nuclear Information System (INIS)

    Sundaram, M.; Wolverson, M.K.; Heiberg, E.; Pilla, T.; Vas, W.G.; Shields, J.B.

    1982-01-01

    Over 200 consecutive diagnostic needle aspiration procedures of the abdomen were performed under computed tomographic (CT) guidance. Biopsies were done of the liver in 88 patients, the pancreas in 28, the kidney in 20, and the retroperitoneum in 32; 30 underwent an aspiration procedure for characterization of an intraabdominal fluid collection. Accuracy of diagnosis was very high for hepatic (99%) and renal (100%) biopsies and in characterization of fluid collections (100%). Accuracy for retroperitoneal biopsy was 87.5% and for pancreatic biopsy 82%. Overall accuracy for all sites was 95%. There were one false-negative diagnosis for the liver and five false-negative diagnoses for the pancreas. Insufficient material was obtained for diagnosis in four instances of retroperitoneal biopsy. There were no false positives. The technique is facilitated by rapid CT scan time, large aperture gantry, and rapid CT image reconstruction. Twenty gauge needles were used more frequently than 22 gauge needles because of their greater rigidity and ease of control. CT-guided diagnostic aspiration procedures are particularly useful for diagnosis of small, deep-seated lesions and in evaluation of lesions found in severely ill patients. An experienced cytologist is essential to the success of the technique

  8. Structure of Ribosomal Silencing Factor Bound to Mycobacterium tuberculosis Ribosome.

    Science.gov (United States)

    Li, Xiaojun; Sun, Qingan; Jiang, Cai; Yang, Kailu; Hung, Li-Wei; Zhang, Junjie; Sacchettini, James C

    2015-10-06

    The ribosomal silencing factor RsfS slows cell growth by inhibiting protein synthesis during periods of diminished nutrient availability. The crystal structure of Mycobacterium tuberculosis (Mtb) RsfS, together with the cryo-electron microscopy (EM) structure of the large subunit 50S of Mtb ribosome, reveals how inhibition of protein synthesis by RsfS occurs. RsfS binds to the 50S at L14, which, when occupied, blocks the association of the small subunit 30S. Although Mtb RsfS is a dimer in solution, only a single subunit binds to 50S. The overlap between the dimer interface and the L14 binding interface confirms that the RsfS dimer must first dissociate to a monomer in order to bind to L14. RsfS interacts primarily through electrostatic and hydrogen bonding to L14. The EM structure shows extended rRNA density that it is not found in the Escherichia coli ribosome, the most striking of these being the extended RNA helix of H54a. Copyright © 2015 Elsevier Ltd. All rights reserved.

  9. Phantom investigation of 3D motion-dependent volume aliasing during CT simulation for radiation therapy planning

    International Nuclear Information System (INIS)

    Tanyi, James A; Fuss, Martin; Varchena, Vladimir; Lancaster, Jack L; Salter, Bill J

    2007-01-01

    To quantify volumetric and positional aliasing during non-gated fast- and slow-scan acquisition CT in the presence of 3D target motion. Single-slice fast, single-slice slow, and multi-slice fast scan helical CTs were acquired of dynamic spherical targets (1 and 3.15 cm in diameter), embedded in an anthropomorphic phantom. 3D target motions typical of clinically observed tumor motion parameters were investigated. Motion excursions included ± 5, ± 10, and ± 15 mm displacements in the S-I direction synchronized with constant displacements of ± 5 and ± 2 mm in the A-P and lateral directions, respectively. For each target, scan technique, and motion excursion, eight different initial motion-to-scan phase relationships were investigated. An anticipated general trend of target volume overestimation was observed. The mean percentage overestimation of the true physical target volume typically increased with target motion amplitude and decreasing target diameter. Slow-scan percentage overestimations were larger, and better approximated the time-averaged motion envelope, as opposed to fast-scans. Motion induced centroid misrepresentation was greater in the S-I direction for fast-scan techniques, and transaxial direction for the slow-scan technique. Overestimation is fairly uniform for slice widths < 5 mm, beyond which there is gross overestimation. Non-gated CT imaging of targets describing clinically relevant, 3D motion results in aliased overestimation of the target volume and misrepresentation of centroid location, with little or no correlation between the physical target geometry and the CT-generated target geometry. Slow-scan techniques are a practical method for characterizing time-averaged target position. Fast-scan techniques provide a more reliable, albeit still distorted, target margin

  10. An experimental displacement and over 50 years of tag-recoveries show that monarch butterflies are not true navigators

    DEFF Research Database (Denmark)

    Mourtisen, Henrik; Derbyshirec, Rachael; Stalleickena, Julia

    2013-01-01

    grounds. When displaced 2,500 km to the west, the same individuals continued to fly in a general southwest direction, suggesting that monarchs use a simple vector-navigation strategy (i.e., use a specific compass bearing without compensating for displacement). Using over 5 decades of field data, we also...... directionality of migration from north to south is largely because of the presence of geographic barriers that guide individuals toward overwintering sites. Our work suggests that monarchs breeding in eastern North America likely combine simple orientation mechanisms with geographic features that funnel them...

  11. A geomorphological characterisation of river systems in South Africa: A case study of the Sabie River

    Science.gov (United States)

    Eze, Peter N.; Knight, Jasper

    2018-06-01

    Fluvial geomorphology affects river character, behaviour, evolution, trajectory of change and recovery potential, and as such affects biophysical interactions within a catchment. Water bodies in South Africa, in common with many other water-stressed parts of the world, are generally under threat due to increasing natural and anthropogenic influences including aridity, siltation and pollution, as well as climate and environmental change. This study reports on a case study to characterise the geomorphology of different river systems in South Africa, with the aim of better understanding their properties, controls, and implications for biophysical interactions including water quality, biodiversity (aquatic and riparian), and human activity within the catchment. The approach adopted is based on the River Styles® framework (RSF), a geomorphology-based approach developed for rivers in New Zealand and Australia, but applied here for the first time to South Africa. Based on analysis of remote sensing imagery, SRTM-2 digital topographic data and field observations on sites through the entire river system, six geomorphic elements were identified along the Sabie River, northeast South Africa (gorge, bedrock-forced meander, low-moderate sinuosity planform controlled sand bed, meandering sand bed, low sinuosity fine grained sand bed, and floodouts), using the RSF classification scheme and based on the RSF procedural tree of Brierley and Fryirs (2005). Previous geomorphological studies along the Sabie River have shown that different reaches respond differently to episodic floods; we use these data to link river geomorphological character (as defined by the RSF) to the hydrodynamic conditions and processes giving rise to such character. This RSF approach can be used to develop a new management approach for river systems that considers their functional biophysical behaviour within individual reaches, rather than considering them as homogeneous and uniform systems.

  12. Evaluation of radioactive seeds implantation under PET-CT guidance for the treatment of central lung cancer with obstructive atelectasis

    International Nuclear Information System (INIS)

    Zhou Yi; Jiang Zhongpu; Wang Haiting; Zhang Yanjun; Jiang Qiang; Wang Jun; Ren Lijun; Xie Bin

    2010-01-01

    Objective: To evaluate percutaneous puncturing 125 I seed implantation by using PET-CT guided target localization technique in treating central lung cancer complicated by obstructive pulmonary atelectasis. Methods: A total of 30 patients with suspected central lung cancer complicated by obstructive pulmonary atelectasis on preoperative chest films were enrolled in this study. As no clear distinction existed between the tumor and the atelectatic consolidation shadow on plain chest films, CT scanning was carried out in all patients. If CT scan was still not able to determine the margin of the tumor, an additional PET-CT scanning was adopted. After ascertaining the location of the lung cancer, percutaneous puncturing implantation of 125 I seeds under PET-CT guidance was performed. The clinical data and the therapeutic results were evaluated. Results: A sharp distinction between the tumor and the atelectatic consolidation shadow was demonstrated on PET-CT scans in 21 cases. The mean volume of the targeted lesion reckoned from PET-CT scans was 26 cm 3 , and the 125 I seeds were implanted. The mean volume of the targeted lesion calculated on CT scans was 37 cm 3 . Six months after the treatment, the follow-up CT exam showed that the effective rate was 93% (28/30). The one-year survival rate was 100% . The complications included pneumothorax (n = 8), small amount of hemoptysis (n = 12) and fever (n = 2). No displacement or immigration of the implanted seeds occurred. Conclusion: PET-CT scanning is far superior to conventional CT scanning in determining the target area of the tumor in patients with central lung cancer complicated by obstructive pulmonary atelectasis. (authors)

  13. Displaced and non-displaced Colombian children's evaluations of moral transgressions, retaliation, and reconciliation

    Science.gov (United States)

    Ardila-Rey, Alicia; Killen, Melanie; Brenick, Alaina

    2015-01-01

    In order to assess the effects of displacement and exposure to violence on children's moral reasoning, Colombian children exposed to minimal violence (non-displaced or low-risk) (N = 99) and to extreme violence (displaced or high-risk) (N = 94), evenly divided by gender, at 6-, 9-, and 12 - years of age, were interviewed regarding their evaluation of peer-oriented moral transgressions (hitting and not sharing toys). The vast majority of children evaluated moral transgressions as wrong. Group and age differences were revealed, however, regarding provocation and retaliation. Children who were exposed to violence, in contrast to those with minimum exposure, judged it more legitimate to inflict harm or deny resources when provoked and judged it more okay to retaliate for reasons of retribution. Surprisingly, and somewhat hopefully, all children viewed reconciliation as feasible. The results are informative regarding theories of morality, culture, and the effects of violence on children's social development. PMID:25722543

  14. CT findings of nasopharyngeal cancer

    International Nuclear Information System (INIS)

    Kim, Kie Hwan; Byun, Hong Sik; Chin, Soo Yil

    1987-01-01

    CT findings in 64 patients of nasopharyngeal cancer are analyzed retrospectively to evaluate the region of origin and the route of spread. The results are as follows: 1. The most frequently involved wall is lateral well (90%), followed by posterior wall (78%) and superior wall (58%). 2. There are invasion to parapharyngeal space (86%), retropharyngeal and prevertebral space (72%), carotid space (46%), and masticator space (18%) in that order. 3. Involved anatomic sites are Rosenmueller fossa (90%), torus tubarius (78%), E-tube orifice (68%), carotid sheath (46%), soft palate (50%), nasal cavity (36%), skull base (28%), prevertebral muscle (26%) and intracranial fossa (16%). 4. Direct extension to intracranial fossa is via sphenoid sinus (6/8), foramen lacerum (5/8), foramen ovale (4/8), and jugular foramen (4/8) in that order. 5. Invasion to prevertebral space leads to intraspinal extension (3/13). 6. Cervical lymph node metastasis of found in internal jugular (82%),spinal accessory (56%) and retropharyngeal chain (42%) in that order. 7. After radiation therapy, most frequent site of recurrence is posterior wall (10/14) followed by lateral wall (9/14), superior wall (5/14) and cervical lymph node (6/14), but the presence of recurrence is difficult to determine based on CT only

  15. Displacement of location in illusory line motion.

    Science.gov (United States)

    Hubbard, Timothy L; Ruppel, Susan E

    2013-05-01

    Six experiments examined displacement in memory for the location of the line in illusory line motion (ILM; appearance or disappearance of a stationary cue is followed by appearance of a stationary line that is presented all at once, but the stationary line is perceived to "unfold" or "be drawn" from the end closest to the cue to the end most distant from the cue). If ILM was induced by having a single cue appear, then memory for the location of the line was displaced toward the cue, and displacement was larger if the line was closer to the cue. If ILM was induced by having one of two previously visible cues vanish, then memory for the location of the line was displaced away from the cue that vanished. In general, the magnitude of displacement increased and then decreased as retention interval increased from 50 to 250 ms and from 250 to 450 ms, respectively. Displacement of the line (a) is consistent with a combination of a spatial averaging of the locations of the cue and the line with a relatively weaker dynamic in the direction of illusory motion, (b) might be implemented in a spreading activation network similar to networks previously suggested to implement displacement resulting from implied or apparent motion, and (c) provides constraints and challenges for theories of ILM.

  16. Evaluation of normal brain CT scan in Korean

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Y. H.; Suh, J. H.; Park, C. Y. [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    1981-06-15

    The safety of procedure combined with wealth of information have resulted in rapid acceptance of CT as a practical and reliable neurodignostic technique. To understand the alternation in tissue density and associated displacement and distortion caused by pathologic lesion in CT, it is necessary to have clear understanding of normal anatomical landmark. For the purpose of establishing normative criteria in Korean for comparative diagnosis, 500 normal CT scan without neurologic sign were studied. The brief results are follows; 1. Among many ventricular index measured for lateral ventricle, the bifrontal CVI is more sensitive and easily determined. Ventricular size increased with age, especially after 6th decade but no difference with sex. 2. Mean width of third ventricle is 5 mm ({+-} 0.3), more wider in male (male; 5.2 mm, female; 4.5 mm) and increased with age. 2. Mean width of fourth ventricle is 13 mm ({+-} 1.3), without difference in age and sex. The shape of ventricle is variable form of triangle. The position of ventricle relative to Twining's line can be determined, so ratio of distance from tuberculum sellae to center of fourth ventricle to Twining's line is between 0.46-0.52. 4. Suprasellar cistern is visible in 89.7% of scan and shape of cistern is found to be pentagonal (73.3%), hexagonal (23.0%) and tetragonal (3.7%). 5. Choroid plexus can be identified in 90% and asymmetrical in 4%. 45% of identified choroid plexus can be visible on scan without contrast enhancement, and more frequently visible in older age.

  17. Evaluation of normal brain CT scan in Koreans

    International Nuclear Information System (INIS)

    Lee, Y. H.; Suh, J. H.; Park, C. Y.

    1981-01-01

    The safety of procedure combined with wealth of information have resulted in rapid acceptance of CT as a practical and reliable neurodiagnostic technique. To understand the alternation in tissue density and associated displacement and distortion caused by pathologic lesion in CT, it is necessary to have clear understanding of normal anatomical landmark. For the purpose of establishing normartive criteria in Koreans for comparative diagnosis, 500 normal CT scan without neurologic sign were studied. The brief results are follows; 1. Among many ventricular index measured for lateral ventricle, the bifrontal CVI is more sensitive and easily determined. Ventricular size increased with age, especially after 6th decade but no difference with sex. 2. Mean width of third ventricle is 5mm( ± 0.3), more wider in male (male; 5.2mm, female; 4.5mm) and increased with age. 3. Mean width of fourth ventricle is 13mm( ± 1.3), without difference in age and sex. The shape of ventricle is variable form of triangle. The position of ventricle relative to Twining's line can be determined, so ratio of distance from tuberculum sellae to center of fourth ventricle to Twining's line is between 0.46-0.52. 4. Suprasellar cistern is visible in 89.7% of scan and shape of cistern is found to be pentagonal (73.3%), hexagonal (23.0%) and tetragonal (3.7%). 5. Choroid plexus can be identified in 90% and asymetrical in 4%. 45% of identified choroid plexus can be visible on scan without contrast enhancement, and more frequently visible in older age

  18. Evaluation of normal brain CT scan in Korean

    International Nuclear Information System (INIS)

    Lee, Y. H.; Suh, J. H.; Park, C. Y.

    1981-01-01

    The safety of procedure combined with wealth of information have resulted in rapid acceptance of CT as a practical and reliable neurodignostic technique. To understand the alternation in tissue density and associated displacement and distortion caused by pathologic lesion in CT, it is necessary to have clear understanding of normal anatomical landmark. For the purpose of establishing normative criteria in Korean for comparative diagnosis, 500 normal CT scan without neurologic sign were studied. The brief results are follows; 1. Among many ventricular index measured for lateral ventricle, the bifrontal CVI is more sensitive and easily determined. Ventricular size increased with age, especially after 6th decade but no difference with sex. 2. Mean width of third ventricle is 5 mm (± 0.3), more wider in male (male; 5.2 mm, female; 4.5 mm) and increased with age. 2. Mean width of fourth ventricle is 13 mm (± 1.3), without difference in age and sex. The shape of ventricle is variable form of triangle. The position of ventricle relative to Twining's line can be determined, so ratio of distance from tuberculum sellae to center of fourth ventricle to Twining's line is between 0.46-0.52. 4. Suprasellar cistern is visible in 89.7% of scan and shape of cistern is found to be pentagonal (73.3%), hexagonal (23.0%) and tetragonal (3.7%). 5. Choroid plexus can be identified in 90% and asymmetrical in 4%. 45% of identified choroid plexus can be visible on scan without contrast enhancement, and more frequently visible in older age

  19. Small cell lung cancer: CT evaluation and comparison with nonhodgkin's lymphoma

    International Nuclear Information System (INIS)

    Whang, Sun Hee; Lee, Kyung Soo; Lee, Byoung Ho

    1991-01-01

    We analyzed plain radiographic and computed tomographic (CT) features of 26 biopsy proven small cell lung cancer (SCLC). Eleven cases of non Hodgkin's lymphoma involving the thorax were also reviewed and compared with the small cell lung cancer for differential diagnostic clues. Centrally manifesting lymphadenopathy was the main findings of SCLC in both plain radiographs and CT. The most frequently involved lymph nodes were subcarinal, right lower paratracheal, left lower paratracheal, and right tracheobronchial node. The most difficult site to identify the lymphadenopathy with simple radiograph was subcarinal, paraesophageal, pulmonary ligamental, anterior mediastinal (group 6), and left upper paratracheal nodes CT scan revealed lymphadenopathy clearly in all of these Groups. Right lower paratracheal and subcarinal nodes were involved frequently in both SCLC's and lymphomas. Bilateral tracheobronchial and bilateral intrapulmonary nodes were involved more frequently in SCLC's while anterior mediastinal, upper paratracheal, and aorticopulmonary (AP) window nodes were involved predominantly in lymphomas. Cystic low attenuation, presumed necrosis lymphadenopathy, was noted in two cases of lymphomas but not found in SCLC's at all. In conclusion, the CT could detect involved lymphadenopathy in SCLC more accurately than plain radiograph and the sites of involved lymphadenopathy may give a differential diagnostic clue between SCLC and lymphoma

  20. Variable displacement alpha-type Stirling engine

    Science.gov (United States)

    Homutescu, V. M.; Bălănescu, D. T.; Panaite, C. E.; Atanasiu, M. V.

    2016-08-01

    The basic design and construction of an alpha-type Stirling engine with on load variable displacement is presented. The variable displacement is obtained through a planar quadrilateral linkage with one on load movable ground link. The physico-mathematical model used for analyzing the variable displacement alpha-type Stirling engine behavior is an isothermal model that takes into account the real movement of the pistons. Performances and power adjustment capabilities of such alpha-type Stirling engine are calculated and analyzed. An exemplification through the use of the numerical simulation was performed in this regard.

  1. Central image archiving and managements system for multicenter clinical studies: Lessons from low-dose CT for appendicitis trial

    Energy Technology Data Exchange (ETDEWEB)

    Ko, You Sun; Lee, Kyong Joon; Lee, Kyoung Ho [Dept. of Radiology, Seoul National University Bundang Hospital, Seongnam (Korea, Republic of); and others

    2017-03-15

    This special report aimed to document our experiences in implementing the Central Imaging Archiving and Management System (CIAMS) for a multicenter clinical trial, Low-dose CT for Appendicitis Trial (LOCAT), supported by the Korean Society of Radiology and Radiology Imaging Network of Korea for Clinical Research. LOCAT was a randomized controlled trial to determine whether low-dose CT is non-inferior to standard-dose CT with respect to the negative appendectomy rate in patients aged from 15 to 44 years. Site investigators downloaded the CT images from the site picture archiving and communication system servers, and uploaded the anonymized images to the primary server. CIAMS administrators inspected the images routed to the secondary server by a cross-check against image submission worksheets provided by the site investigators. The secondary server was automatically synchronized to the tertiary backup server. Up to June 2016, 2715 patients from 20 sites participated in LOCAT for 30 months. A total of 2539 patients' images (93.5%, 2539/2715) were uploaded to the primary server, 2193 patients' worksheets (80.8%, 2193/2715) were submitted, and 2163 patients' data (79.7%, 2163/2715) were finally monitored. No data error occurred.

  2. Interobserver variability in the detection of mediastinal and hilar lymph nodes on CT in children with suspected pulmonary tuberculosis

    International Nuclear Information System (INIS)

    Andronikou, Savvas; Brauer, Barbara; Brachmeyer, Steven; Lucas, Susan; Joseph, Elaine; Galpin, Jackie; DuToit, George; Swingler, George

    2005-01-01

    The presence of mediastinal or hilar adenopathy is critical for the diagnosis of pulmonary TB. Interobserver variability in the detection of lymphadenopathy on CT in children affects the usefulness of CT as a gold standard. To determine the interobserver variability for the detection of hilar and mediastinal adenopathy on CT in children. One hundred children with clinically suspected pulmonary TB were prospectively recruited for CT scanning of the chest. Four observers reviewed the scans independently for the presence of lymphadenopathy at predetermined sites. Overall Kappa statistic was determined for each recognised site of mediastinal and hilar lymphadenopathy. Kappa statistics showed that observers only agreed moderately in their detection of lymphadenopathy. The site of best agreement was the right hilum followed by the subcarinal, right paratracheal and precarinal locations. Observers differed most at the anterior mediastinum and left hilum. The best Kappa statistic was for the overall presence of lymphadenopathy taking all sites into account. Imaging techniques that are considered the gold standard for particular diseases must be validated pathologically, and if this is not possible, interobserver variability should be evaluated. CT is considered the gold standard for detecting lymphadenopathy, but we have shown only moderate agreement between readers. Readers had difficulty in distinguishing lymphadenopathy from normal thymus and were unable to distinguish normal from pathological nodes without a predetermined size threshold for abnormality. The right hilum and the sites around the carina are the most reliable for the reported presence of lymphadenopathy. (orig.)

  3. CT bronchus sign in malignant solitary pulmonary lesions: value in the prediction of cell type

    International Nuclear Information System (INIS)

    Choi, J.A.; Kim, J.H.; Hong, K.T.; Kim, H.S.; Oh, Y.W.; Kang, E.Y.

    2000-01-01

    The aim of this study was to evaluate differences in the prevalence of patterns of CT bronchus sign in malignant solitary pulmonary lesions (SPLs), according to their histologic cell types and with respect to size, location, and degree of cell differentiation. Computed tomography scans of 78 patients, in whom pathologically confirmed malignant SPLs with CT bronchus sign were present, were randomly selected and reviewed by two radiologists under consensus. All 78 were CT scans done using spiral technique with 10-mm collimation and 10-mm reconstruction intervals with enhancement, and 75 included additional high-resolution CT scans. Lesions were classified into four cell types as squamous cell carcinoma (n=24), small cell carcinoma (n=12), adenocarcinoma (n=23), bronchioloalveolar carcinoma (BAC; n=9), and others (n=12), into three degrees of differentiation, into three size groups, and according to location (central or peripheral). Patterns of CT bronchus sign were classified into abruptly obstructing (I), patent (II), displacing (III), or tapered narrowing (IV) types. The relationships between the patterns of CT bronchus sign and cell type and degree of cell differentiation were evaluated. Eighty patterns of CT bronchus sign were observed in 78 patients. According to cell type, squamous cell carcinoma showed most often type-I pattern (45.8%) but no type-II pattern, which was the most common pattern observed in BAC (77.8%) and adenocarcinoma (34.8%; p<0.01). Small cell carcinoma showed a varied distribution among the four patterns of CT bronchus sign. According to location, in central squamous cell carcinomas, type-I pattern was more common(55%; p<0.01). Bronchioloalveolar carcinoma showed more peripheral lesions and in both central and peripheral lesions, type-II pattern was significantly more common (100 and 66.7%; p<0.01). In SPLs with CT bronchus sign of obstructing pattern, especially if central location, squamous cell carcinoma should be suspected, whereas in

  4. Neutron displacement damage cross sections for SiC

    International Nuclear Information System (INIS)

    Huang Hanchen; Ghoniem, N.

    1993-01-01

    Calculations of neutron displacement damage cross sections for SiC are presented. We use Biersack and Haggmark's empirical formula in constructing the electronic stopping power, which combines Lindhard's model at low PKA energies and Bethe-Bloch's model at high PKA energies. The electronic stopping power for polyatomic materials is computed on the basis of Bragg's Additivity Rule. A continuous form of the inverse power law potential is used for nuclear scattering. Coupled integro-differential equations for the number of displaced atoms j, caused by PKA i, are then derived. The procedure outlined above gives partial displacement cross sections, displacement cross sections for each specie of the lattice, and for each PKA type. The corresponding damage rates for several fusion and fission neutron spectra are calculated. The stoichiometry of the irradiated material is investigated by finding the ratio of displacements among various atomic species. The role of each specie in displacing atoms is also investigated by calculating the fraction of displacements caused by each PKA type. The study shows that neutron displacement damage rates of SiC in typical magnetic fusion reactor first walls will be ∝10-15 dpa MW -1 m 2 ; in typical lead-protected inertial confinement fusion reactor first walls they will be ∝15-20 dpa MW -1 m 2 . For fission spectra, we find that the neutron displacement damage rate of SiC is ∝74 dpa per 10 27 n/m 2 in FFTF, ∝39 dpa per 10 27 n/m 2 in HFIR, and 25 dpa per 10 27 n/m 2 in NRU. Approximately 80% of displacement atoms are shown to be of the carbon-type. (orig.)

  5. Groundwater resources monitoring and population displacement in northern Uganda

    Science.gov (United States)

    Chalikakis, K.; Hammache, Y.; Nawa, A.; Slinski, K.; Petropoulos, G.; Muteesasira, A.

    2009-04-01

    Northern Uganda has been devastated by more than 20 years of open conflict by the LRA (Lord's Resistance Army) and the Government of Uganda. This war has been marked by extreme violence against civilians, who had been gathered in protected IDP (Internally Displaced Persons) camps. At the height of the displacement in 2007, the UN office for coordination of humanitarian affairs, estimated that nearly 2.5 million people were interned into approximately 220 camps throughout Northern Uganda. With the improved security since mid-2006, the people displaced by the conflict in Northern Uganda started to move out of the overcrowded camps and return either to their villages/parishes of origin or to resettlement/transit sites. However, basic water, sanitation and hygiene infrastructure in the return areas or any new settlements sites are minimal. People returning to their villages of origin encounter a situation where in many cases there is no access to safe water. Since 1998 ACF (Action Against Hunger, part of the Action Contre la Faim International Network) activities have been concentrated in the Acholi and Lango regions of Northern Uganda. ACF's WASH (Water, sanitation and hygiene) department interventions concern sanitation infrastructure, hygiene education and promotion as well as water points implementation. To ensure safe water access, actions are focused in borehole construction and traditional spring rehabilitation, also called "protected" springs. These activities follow the guidelines as set forth by the international WASH cluster, led by UNICEF. A three year project (2008-2010) is being implemented by ACF, to monitor the available groundwater resources in Northern Uganda. The main objectives are: 1. to monitor the groundwater quality from existing water points during different hydrological seasons, 2. to identify, if any, potential risks of contamination from population concentrations and displacement, lack of basic infrastructure and land use, and finally 3. to

  6. Asymmetric SOL Current in Vertically Displaced Plasma

    Science.gov (United States)

    Cabrera, J. D.; Navratil, G. A.; Hanson, J. M.

    2017-10-01

    Experiments at the DIII-D tokamak demonstrate a non-monotonic relationship between measured scrape-off layer (SOL) currents and vertical displacement event (VDE) rates with SOL currents becoming largely n=1 dominant as plasma is displaced by the plasma control system (PCS) at faster rates. The DIII-D PCS is used to displace the magnetic axis 10x slower than the intrinsic growth time of similar instabilities in lower single-null plasmas. Low order (n VDE instabilities observed when vertical control is disabled. Previous inquiry shows VDE asymmetry characterized by SOL current fraction and geometric parameters of tokamak plasmas. We note that, of plasmas displaced by the PCS, short displacement time scales near the limit of the PCS temporal control appear to result in larger n=1/n=2 asymmetries. Work supported under USDOE Cooperative Agreement DE-FC02-04ER54698 and DE-FG02-04ER54761.

  7. Internal displacement in Colombia: Fifteen distinguishing features.

    Science.gov (United States)

    Shultz, James M; Ceballos, Ángela Milena Gómez; Espinel, Zelde; Oliveros, Sofia Rios; Fonseca, Maria Fernanda; Florez, Luis Jorge Hernandez

    2014-01-01

    This commentary aims to delineate the distinguishing features of conflict-induced internal displacement in the nation of Colombia, South America. Even as Colombia is currently implementing a spectrum of legal, social, economic, and health programs for "victims of armed conflict," with particular focus on internally displaced persons (IDPs), the dynamics of forced migration on a mass scale within this country are little known beyond national borders.   The authors of this commentary are embarking on a global mental health research program in Bogota, Colombia to define best practices for reaching the displaced population and implementing sustainable, evidence-based screening and intervention for common mental disorders. Presenting the defining characteristics of internal displacement in Colombia provides the context for our work and, more importantly, conveys the compelling and complex nature of this humanitarian crisis. We attempt to demonstrate Colombia's unique position within the global patterning of internal displacement.

  8. Do environmental changes or juvenile competition act as mechanisms of species displacement in crayfishes?

    Science.gov (United States)

    Westhoff, Jacob T.; DiStefano, R.J.; Magoulick, D.D.

    2012-01-01

    The Big Creek Crayfish, Orconectes peruncus, is native to the St. Francis River drainage in Missouri, USA and is often absent where the introduced Woodland Crayfish, Orconectes hylas, has established. We performed a field experiment to determine whether effects of current abiotic conditions and interspecific competition with O. hylas were responsible for displacement of O. peruncus from parts of their former range. We examined growth and survival of juvenile male O. peruncus exposed to juvenile male O. hylas in enclosures at two sites in the former range of O. peruncus. Enclosures contained 8 (low density) or 16 individuals (high density) and had O. peruncus only (control) or both species (interspecific treatment). Juvenile O. peruncus were able to survive and grow in portions of their former range, implicating biotic versus abiotic factors in the displacement of O. peruncus. Survival rates of O. peruncus did not differ among treatments at either site. Orconectes peruncus showed significant growth in all treatments and interspecific effects were not greater than intraspecific effects on O. peruncus growth rates. High-density treatments showed significantly reduced O. peruncus growth rates compared to low-density treatments, except in Carver Creek interspecific treatments. When considered in the context of previous studies examining the effects of O. hylas on O. peruncus, results suggest that neither direct competition between juvenile males of the two species or abiotic change are responsible for the decreased range of O. peruncus. Additional research is required to determine the mechanism(s) driving the displacement of O. peruncus. ?? 2011 Springer Science+Business Media B.V.

  9. Pediatric renal leukemia: spectrum of CT imaging findings

    International Nuclear Information System (INIS)

    Hilmes, Melissa A.; Dillman, Jonathan R.; Mody, Rajen J.; Strouse, Peter J.

    2008-01-01

    The kidneys are a site of extramedullary leukemic disease that can be readily detected by CT. To demonstrate the spectrum of CT findings in children with renal leukemic involvement. Twelve children were identified retrospectively as having renal leukemic involvement by contrast-enhanced CT of the abdomen. Contrast-enhanced CT images through the kidneys of each patient were reviewed by two pediatric radiologists. Pertinent imaging findings and renal lengths were documented. The electronic medical record was accessed to obtain relevant clinical and pathologic information. Five patients with renal leukemic involvement presented with multiple bilateral low-attenuation masses, while three patients demonstrated large areas of wedge-shaped and geographic low attenuation. Four other patients presented with unique imaging findings, including a solitary unilateral low-attenuation mass, solitary bilateral low-attenuation masses, multiple bilateral low-attenuation masses including unilateral large conglomerate masses, and bilateral areas of ill-defined parenchymal low attenuation. Two patients showed unilateral nephromegaly, while eight other patients showed bilateral nephromegaly. Two patients had normal size kidneys. Two patients had elevated serum creatinine concentrations at the time of imaging. Renal leukemic involvement in children can present with a variety of CT imaging findings. Focal renal abnormalities as well as nephromegaly are frequently observed. Most commonly, renal leukemic involvement does not appear to impair renal function. (orig.)

  10. Pediatric renal leukemia: spectrum of CT imaging findings

    Energy Technology Data Exchange (ETDEWEB)

    Hilmes, Melissa A. [University of Michigan Health System, C.S. Mott Children' s Hospital, Section of Pediatric Radiology, Ann Arbor, MI (United States); Vanderbilt University Children' s Hospital, Section of Pediatric Radiology, Nashville, TN (United States); Dillman, Jonathan R. [University of Michigan Health System, C.S. Mott Children' s Hospital, Section of Pediatric Radiology, Ann Arbor, MI (United States); University of Michigan Health System, Department of Radiology, Ann Arbor, MI (United States); Mody, Rajen J. [University of Michigan Health System, C.S. Mott Children' s Hospital, Division of Pediatric Hematology-Oncology and Bone Marrow Transplantation, Ann Arbor, MI (United States); Strouse, Peter J. [University of Michigan Health System, C.S. Mott Children' s Hospital, Section of Pediatric Radiology, Ann Arbor, MI (United States)

    2008-04-15

    The kidneys are a site of extramedullary leukemic disease that can be readily detected by CT. To demonstrate the spectrum of CT findings in children with renal leukemic involvement. Twelve children were identified retrospectively as having renal leukemic involvement by contrast-enhanced CT of the abdomen. Contrast-enhanced CT images through the kidneys of each patient were reviewed by two pediatric radiologists. Pertinent imaging findings and renal lengths were documented. The electronic medical record was accessed to obtain relevant clinical and pathologic information. Five patients with renal leukemic involvement presented with multiple bilateral low-attenuation masses, while three patients demonstrated large areas of wedge-shaped and geographic low attenuation. Four other patients presented with unique imaging findings, including a solitary unilateral low-attenuation mass, solitary bilateral low-attenuation masses, multiple bilateral low-attenuation masses including unilateral large conglomerate masses, and bilateral areas of ill-defined parenchymal low attenuation. Two patients showed unilateral nephromegaly, while eight other patients showed bilateral nephromegaly. Two patients had normal size kidneys. Two patients had elevated serum creatinine concentrations at the time of imaging. Renal leukemic involvement in children can present with a variety of CT imaging findings. Focal renal abnormalities as well as nephromegaly are frequently observed. Most commonly, renal leukemic involvement does not appear to impair renal function. (orig.)

  11. Usefulness of preoperative three dimensional CT in laparoscopic cholecystectomy. Especially, its comparison to ERC

    International Nuclear Information System (INIS)

    Machida, Hiromichi; Nakaya, Yuzou; Kojima, Kojirou

    1996-01-01

    We studied the usefulness of three dimensional helical CT (3D-CT) combined with drip infusion cholangiography for determining the application of laparoscopic cholecystectomy (LC) and evaluating the cholecyst severity. The subjects were 56 patients who underwent LC with preoperative 3D-CT. Particularly, in 42 patients undergoing endoscopic retrograde cholangiography (ERC) and 3D-CT simultaneously, the results with both methods were compared. The detection rates of the original site, forward and backward direction, and left and right direction in the confluence form of the cystic duct by means of 3D-CT versus ERC were 100% vs. 92.9% 92.9% vs. 71.4%, and 92.9% vs. 88.1%, respectively. Abnormal biliary distribution was visualized in 5 cases and all of them were depicted by 3D-CT. The 3D-CT was superior to ERC in terms of X-ray dose and cost. These results indicate the usefulness of 3D-CT as a LC preoperative examination. (author)

  12. Comparison of the effects of salmon calcitonin (sCT) and calcitonin gene-related peptide (CGRP) in a number of in vivo and in vitro tests

    International Nuclear Information System (INIS)

    Welch, S.P.; Brase, D.; Cooper, C.; Dewey, W.L.

    1986-01-01

    sCT and CGRP have been shown previously to have multiple activities in the central nervous system (CNS). Recent work has shown that CGRP (15 μg) intraventricularly (IVT) produces a naloxone reversible 37% inhibition in the p-phenylquinone test (PPQ) accompanied by severe diarrhea. The ED50 of sCT in the PPQ test is 362 ng and this effect is not reversed totally by naloxone. The onset of CGRP is more rapid than that of sCT. sCT and CGRP (10 -6 M) both produce naloxone reversible inhibition of the electrically stimulated guinea pig ileum (GPI) (25% and 50% respectively). Both sCT and CGRP (10 -6 M) produce contracture (15% and 40% respectively) of the non-stimulated GPI that is not blocked by atropine. Both sCT and CGRP block the naloxone-induced contracture of the morphine (MS04) dependent ilea (29% and 68% respectively). Both sCT and CGRP produce biphasic shifts in the MS04 acetylcholine dose-effect curves in the stimulated and nonstimulated GPI, respectively. Neither sCT nor CGRP (10 -9 to 10 -4 M) displaces 3 H-naloxone binding to mouse brain membranes. Both sCT and CGRP may produce their effects by modulation of CA +2 fluxes in the CNS and GPI

  13. Contrast-enhanced computed tomography does not improve the diagnostic value of parathyroid dual-phase MIBI SPECT/CT

    DEFF Research Database (Denmark)

    Andersen, Trine B; Aleksyniene, Ramune; Boldsen, Søren K

    2018-01-01

    OBJECTIVE: The aim of this study was to investigate the contribution of contrast-enhanced computed tomography (CE-CT) to the localization of parathyroid adenomas compared with the dual-phase Tc-99m MIBI SPECT with low-dose CT (LD-CT). PATIENTS AND METHODS: This retrospective study included...... consecutive patients with primary hyperparathyroidism who underwent a preoperative dual-phase MIBI SPECT/CT followed by surgical resection. The standard of care was dual-phase MIBI SPECT/CT, acquired with LD-CT in the early phase and CE-CT in the late phase (SPECT/CE-CT). The presence and localization...... of positive sites were extracted from study reports. To examine the role of CE-CT, patient cases were independently re-reviewed, with the early LD-CT fused with early and late SPECT (SPECT/LD-CT). The two SPECT/CT methods were compared for sensitivity, and the positive predictive value and histopathology were...

  14. Force transmissibility versus displacement transmissibility

    Science.gov (United States)

    Lage, Y. E.; Neves, M. M.; Maia, N. M. M.; Tcherniak, D.

    2014-10-01

    It is well-known that when a single-degree-of-freedom (sdof) system is excited by a continuous motion of the foundation, the force transmissibility, relating the force transmitted to the foundation to the applied force, equals the displacement transmissibility. Recent developments in the generalization of the transmissibility to multiple-degree-of-freedom (mdof) systems have shown that similar simple and direct relations between both types of transmissibility do not appear naturally from the definitions, as happens in the sdof case. In this paper, the authors present their studies on the conditions under which it is possible to establish a relation between force transmissibility and displacement transmissibility for mdof systems. As far as the authors are aware, such a relation is not currently found in the literature, which is justified by being based on recent developments in the transmissibility concept for mdof systems. Indeed, it does not appear naturally, but the authors observed that the needed link is present when the displacement transmissibility is obtained between the same coordinates where the applied and reaction forces are considered in the force transmissibility case; this implies that the boundary conditions are not exactly the same and instead follow some rules. This work presents a formal derivation of the explicit relation between the force and displacement transmissibilities for mdof systems, and discusses its potential and limitations. The authors show that it is possible to obtain the displacement transmissibility from measured forces, and the force transmissibility from measured displacements, opening new perspectives, for example, in the identification of applied or transmitted forces. With this novel relation, it becomes possible, for example, to estimate the force transmissibility matrix with the structure off its supports, in free boundary conditions, and without measuring the forces. As far as force identification is concerned, this

  15. The Chinese Export Displacement Effect Revisited

    DEFF Research Database (Denmark)

    Elleby, Christian; Yu, Wusheng; Yu, Qian

    China’s global export share has increased dramatically over the past decades. This development has prompted an empirical literature on whether Chinese exports displace those originated from elsewhere in various destination markets. In this paper we focus on the growth of China’s exports to the East...... African Community (EAC) countries and show how it has affected exports from the European Union (EU) to the EAC. Our main contribution to the literature on the displacement effect of Chinese exports is a set of total and relative displacement estimates based on different specifications of the gravity model...... where we control for country-year fixed effects so as to avoid the “gold medal mistake” of not accounting for time varying “multilateral resistance”. Our findings do not support the hypothesis that Chinese exports have displaced exports from other countries in general. Nor do they support the hypothesis...

  16. The Three Gorges: the unexamined toll of development-induced displacement

    Directory of Open Access Journals (Sweden)

    Martin Stein

    1998-04-01

    Full Text Available In China, the context of forced displacement in its broadest sense centres on four issues: (1 coercive displacement for development; (2 political persecution resulting in controlled displacement; (3 massive labour dislocations; and (4 disaster-induced displacement. This article looks at the role of the state in displacement, focusing on the first of these issues: development-induced displacement.

  17. A new classification for cervical vertebral injuries: influence of CT

    Energy Technology Data Exchange (ETDEWEB)

    Daffner, R.H.; Brown, R.R.; Goldberg, A.L. [Department of Diagnostic Radiology, Allegheny University Hospitals, Allegheny General, Pittsburgh, PA (United States)

    2000-03-30

    Objective. Computed tomography (CT) has been demonstrated to be superior to radiography in identifying cervical vertebral injuries. However, many of these injuries may not be clinically significant, and require only minimal symptomatic and supportive treatment. It is therefore imperative that radiologists and spine surgeons have criteria for distinguishing between those injuries requiring surgical stabilization and those that do not. The authors propose a new classification of cervical vertebral injuries into two categories: major and minor.Design and patients. A data base, acquired on 1052 separate cervical injuries in 879 patients seen between 1983 and 1998, was reviewed. Four categories of injury based on mechanism [hyperflexion (four variants), hyperextension (two variants), rotary (two variants), and axial compression (five variants)] were identified. ''Major'' injuries are defined as having either radiographic or CT evidence of instability with or without associated localized or central neurologic findings, or have the potential to produce the latter. ''Minor'' injuries have no radiographic and/or CT evidence of instability, are not associated with neurologic findings, and have no potential to cause the latter.Results and conclusions. Cervical injury should be classified as ''major'' if the following radiographic and/or CT criteria are present: displacement of more than 2 mm in any plane, wide vertebral body in any plane, wide interspinous/interlaminar space, wide facet joints, disrupted posterior vertebral body line, wide disc space, vertebral burst, locked or perched facets (unilateral or bilateral), ''hanged man'' fracture of C2, dens fracture, and type III occipital condyle fracture. All other types of fractures may be considered ''minor''. (orig.)

  18. Statistical characteristics of ionogram spread-F and satellite traces over a Chinese low-latitude station Sanya

    Science.gov (United States)

    Zhu, Zhengping; Lan, Jiaping; Luo, Weihua; Sun, Fenglou; Chen, Kun; Chang, Shanshan

    2015-11-01

    Ionosonde ionogram measurements over Sanya (18°N, 109°E; 13°N dip latitude), China during 2012-2013 are used to investigate the occurrence characteristics of spread-F (SF) and satellite traces (STs), and the possible correlation between them under the weak solar maximum of solar cycle 24. The SF and STs were manually identified from ionograms. The results show that the diurnal pattern of SF peaks at post-sunset during equinox, and at post-midnight during summer months, respectively. By classifying the SF into range spread-F (RSF) and frequency spread-F (FSF), it is found that the SF during equinox are mostly RSF associated with the equatorial F-region irregularities and can be explained by the generalized Rayleigh-Taylor instability. A statistics on the RSF and STs shows that not all RSF events were preceded by STs, and not all STs led to RSF development. The monthly mean value of the sunset ionospheric F2 layer peak height (hmF2) on RSF days is apparently higher than that on non RSF days. This result provides statistically consistent evidence that both the sunset rapid rising of the F-layer and the presence of F-region bottomside density perturbations (as indicated by STs) are important factors for the equinoctial RSF onset and development. However in summer months, the occurrences of RSF and FSF are comparable. Most FSF initiated at midnight. And there was no close relationship between the summer time FSF, F-layer height increase and STs. We suggest that the midnight FSF during summer months observed over Sanya might not be resulting from the decaying of post-sunset RSF initiated at equatorial latitude, but due to the quite localized generation of F-region irregularities.

  19. Brain CT findings in head injury with skull fracture

    International Nuclear Information System (INIS)

    Jeong, In Tae; Lee, Hae Kyung; Chung, Mi Kyung; Kwon, Kwi Hyang; Kim, Ki Jeong

    1982-01-01

    CT has revolutionized the evaluation and management of patients with head injuries. CT in non-invasion and rapidly provides accurate information regarding the presence, extent and nature of intracranial lesions resulting from trauma. We have reviewed the CT scans of 114 patients, who got head injury with confirmed to skull fracture in plain films. The results were as follows: 1. Of all cases, traffic accident was the most frequent cause and in children fall down was more than 50%. 2. Compound linear fracture was the most frequent type fractures in plain skull film.3. Of all 114 cases, epidural hematoma was 16%, subdural hematoma was 18.4%, intracerebral hematoma was 14.4%, subdural hygroma was 2.4%, normal finding was 50%. 4. Mortality rate was 13.2%. 5. Fracture was detected by CT about 28.9%, depression fracture was more easily detected in CT. 6. Incidence rate of counter coup lesion was 14.9% and mortality rate was higher than same site lesion. 7. The shape of epidural hematoma was biconvex in 75%, planoconvex in 25%. 8. The shape of subdural hematoma was cresentic shape 82.6%, biconvex shape 8.7%, planoconvex shape 8.7%

  20. The value of X-ray CT in orbital fractures

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Myung Hee; Lee, Jae Mun; Kim, Choon Yul; Bahk, Yong Whee [Catholic Medical College, Seoul (Korea, Republic of)

    1986-08-15

    On the pulse from the trauma transiting to posterior side of the orbit, orbital fractures are occurred through the weak point of the orbital wall. Invagination of soft tissue or entrapment of muscles may be associated with orbital fracture. In condition of inaccurate diagnosis, appropriate surgical repairment is impossible and complication such as diplopia or enophthalmia are developed. CT scan is diagnostic procedure which demonstrates accurately the site and state of orbital fracture, and its associated findings. The authors has been studied in 21 orbital CT scan to evaluate the relative value of plain X rays and CT scans in the diagnosis of orbital fractures during the period from January 1982 to September 1985. The conclusions were as follows: 1. Diagnostic rate was 100% by CT, 40% by initial and 80% by retrospective interpretation of conventional X-ray films. 2. Low X-ray diagnostic rate of medical wall fractures (26.7%) was due to thinness of the bone. 3. Medial wall fractures were associated with floor fractures in 46%. 4. Orbital soft tissue injuries and abnormalities of PNS were precisely evaluated by CT scan.

  1. Realistic simulation of reduced-dose CT with noise modeling and sinogram synthesis using DICOM CT images

    International Nuclear Information System (INIS)

    Won Kim, Chang; Kim, Jong Hyo

    2014-01-01

    Purpose: Reducing the patient dose while maintaining the diagnostic image quality during CT exams is the subject of a growing number of studies, in which simulations of reduced-dose CT with patient data have been used as an effective technique when exploring the potential of various dose reduction techniques. Difficulties in accessing raw sinogram data, however, have restricted the use of this technique to a limited number of institutions. Here, we present a novel reduced-dose CT simulation technique which provides realistic low-dose images without the requirement of raw sinogram data. Methods: Two key characteristics of CT systems, the noise equivalent quanta (NEQ) and the algorithmic modulation transfer function (MTF), were measured for various combinations of object attenuation and tube currents by analyzing the noise power spectrum (NPS) of CT images obtained with a set of phantoms. Those measurements were used to develop a comprehensive CT noise model covering the reduced x-ray photon flux, object attenuation, system noise, and bow-tie filter, which was then employed to generate a simulated noise sinogram for the reduced-dose condition with the use of a synthetic sinogram generated from a reference CT image. The simulated noise sinogram was filtered with the algorithmic MTF and back-projected to create a noise CT image, which was then added to the reference CT image, finally providing a simulated reduced-dose CT image. The simulation performance was evaluated in terms of the degree of NPS similarity, the noise magnitude, the bow-tie filter effect, and the streak noise pattern at photon starvation sites with the set of phantom images. Results: The simulation results showed good agreement with actual low-dose CT images in terms of their visual appearance and in a quantitative evaluation test. The magnitude and shape of the NPS curves of the simulated low-dose images agreed well with those of real low-dose images, showing discrepancies of less than +/−3.2% in

  2. CT colonography: Project of High National Interest No. 2005062137 of the Italian Ministry of Education, University and Research (MIUR).

    Science.gov (United States)

    Neri, E; Laghi, A; Regge, D; Sacco, P; Gallo, T; Turini, F; Talini, E; Ferrari, R; Mellaro, M; Rengo, M; Marchi, S; Caramella, D; Bartolozzi, C

    2008-12-01

    The aim of this paper is to describe the Web site of the Italian Project on CT Colonography (Research Project of High National Interest, PRIN No. 2005062137) and present the prototype of the online database. The Web site was created with Microsoft Office Publisher 2003 software, which allows the realisation of multiple Web pages linked through a main menu located on the home page. The Web site contains a database of computed tomography (CT) colonography studies in the Digital Imaging and Communications in Medicine (DICOM) standard, all acquired with multidetector-row CT according to the parameters defined by the European Society of Abdominal and Gastrointestinal Radiology (ESGAR). The cases present different bowel-cleansing and tagging methods, and each case has been anonymised and classified according to the Colonography Reporting and Data System (C-RADS). The Web site is available at http address www.ctcolonography.org and is composed of eight pages. Download times for a 294-Mbyte file were 33 min from a residential ADSL (6 Mbit/s) network, 200 s from a local university network (100 Mbit/s) and 2 h and 50 min from a remote academic site in the USA. The Web site received 256 accesses in the 22 days since it went online. The Web site is an immediate and up-to-date tool for publicising the activity of the research project and a valuable learning resource for CT colonography.

  3. Displaced Homemakers: Vo-Tech Workshop Guide.

    Science.gov (United States)

    Peltier, Wanda Jo

    Written for displaced homemaker programs in vocational-technical schools, this curriculum contains material designed so that instructors can prepare student manuals appropriate to almost any educational support situation for displaced homemakers. An overview provides information on special needs groups, curriculum use, and resources and sample…

  4. PET/CT in lymphoma patients; PET-CT bei Lymphompatienten

    Energy Technology Data Exchange (ETDEWEB)

    Steinert, H.C. [Universitaetsspital Zuerich, Klinik und Poliklinik fuer Nuklearmedizin (Switzerland)

    2004-11-01

    First results of PET/CT in Hodgkin's disease (HD) and aggressive non-Hodgkin's lymphoma (NHL) are reported. From March 2001 to August 2004 822 PET/CT were performed at our clinic in lymphoma patients for primary staging, restaging after therapy, and diagnosis of recurrence. For coregistration non contrast-enhanced low-dose CT were used. Due to the exact anatomic localization of {sup 18}F-FDG accumulating lesions equivocal or false positive PET findings are avoided. In comparison to contrast enhanced CT, PET/CT has a higher sensitivity and specificity in patients with HD and aggressive NHL. Integration of PET/CT in treatment planning of radiation therapy optimizes the field volume. Even in the initial phase of clinical evaluation, PET/CT has proven useful in staging and restaging of lymphoma. The exact anatomic localization of the PET findings is essential for a precise report, for treatment planning of radiation therapy, and for planning surgical biopsy. (orig.) [German] Erste Ergebnisse der PET-CT bei Morbus Hodgkin (HD) und den aggressiven Non-Hodgkin-Lymphomen (NHL) werden beschrieben. Von Maerz 2001 bis August 2004 wurden 822 PET-CT bei Lymphompatienten zum primaeren Staging, zum Restaging nach Therapie und zur Rezidivdiagnostik an unserer Klinik durchgefuehrt. Fuer die Koregistration wurde ein Low-dose-CT ohne i.v.-Kontrastmittel verwendet. Durch die exakte anatomische Zuordnung der {sup 18}F-FDG aufnehmenden Laesionen wurden unklare oder falsch-positive PET-Befunde vermieden. Die PET-CT erzielte im Vergleich zur KM-verstaerkten CT eine hoehere Sensitivitaet und Spezifitaet bei Patienten mit HD und aggressiven NHL. Die Integration der PET-CT in die Planung der Strahlentherapie fuehrte zu einer Optimierung der Feldgrenzen. Die PET-CT hat sich bereits in der Phase der initialen klinischen Evaluation als wertvoll beim Staging und Restaging von Lymphomen erwiesen. Die exakte anatomische Zuordnung der PET-Informationen ist fuer eine sichere Befundung

  5. CT diagnosis of abdominal ectopic pheochromocytoma

    International Nuclear Information System (INIS)

    Zhang Yuping; Zhao Zhiying

    2010-01-01

    Objective: To discuss the value of CT in diagnosis of abdominal ectopic pheochromocytoma. Methods: CT findings of 5 cases surgically and pathologically proved with ectopic pheochromocytoma were retrospectively analyzed. Results: Soft tissue mass with light asymmetry enhancement was found between the abdominal aorta and the inferior vena ca-va in one case. 1 case was completely cystic with light enhancement of the cystwall located in front of the left side of the abdominal aorta. 1 case of large solid mass occurred between the renal hilum and the tail of pancreas, with irregular shape, unclear boundary, central necrosis, calcification and obviously enhancement at the solid part. 2 cases showed as oval soft lump with even density, moderate strengthening located before the abdominal aorta. Paroxysmal hypertension occurred in 3 cases and didn't in 2 cases. Hypertension happened in 1 case during the operation because of stimulation. Blood pressure appeared in 1 case during and after operation. Blood and urinary catecholamine increased significantly in 4 cases. Conclusion: Ectopic pheochromocytoma mainly located surround the abdominal aorta with diverse CT performance. It is helpful for diagnosing when finding a lesion locates at the specified sites combined with typical clinical presentation. CT can not only depict small tumor, but also can show the relationship with surrounding structure, and it provides important information for the operation and prognosis. (authors)

  6. Quantification of C2 cervical spine rotatory fixation by X-ray, MRI and CT

    Energy Technology Data Exchange (ETDEWEB)

    Gradl, Georg [Chirurgische Klinik und Poliklinik der Universitaet Rostock, Abteilung Unfall- und Wiederherstellungschirurgie, Rostock (Germany); Maier-Bosse, Tamara; Staebler, Axel [Institut fuer Radiologische Diagnostik der Universitaet Muenchen, Klinikum Grobetahadern, Munich (Germany); Penning, Randolph [Institut fuer Rechtsmedizin der Universitaet Muenchen, Munich (Germany)

    2005-02-01

    Atlanto-axial rotatory displacement is known to be a cause of childhood torticollis and may as well be responsible for chronic neck pain after rear-end automobile collisions. The objective was to determine whether quantification of C2 malrotation is possible by plain radiographs in comparison to CT as the golden standard. MR imaging was evaluated as to whether it was of equal value in the detection of bony landmarks. C2 vertebra of five human cadaveric cervical spine specimens, ligamentously intact, were rotated using a Steinmann pin in steps of 5 up to 15 right and 15 left. Plain radiographs, CT and MRI images were taken in each rotational step. Data were analyzed for quantification of C2 rotation by three independent examiners. A rotation of 5 led to a spinous process deviation (SPD) from the midline of 3 mm as measured on an a.p. plain radiograph. A coefficient of rotation was calculated (1.62 mm{sup -1}). Data analyzed by three examiners revealed a small coefficient of variation (0.03). MRI and CT measurements showed comparable results for the quantification of rotation; however, in both techniques the 15 rotation was underestimated. Quantification of upper cervical spine malrotation was possible on plain radiographs using the SPD and a rotation coefficient. MRI and CT were equally successful in the assessment of C2 malrotation. (orig.)

  7. Atypical case of Reye's syndrome. Usefulness of CT for diagnosis and follow-up study

    Energy Technology Data Exchange (ETDEWEB)

    Maehara, Fumiaki; Goto, Katsuya; Okudera, Toshio; Mitsudome, Akihisa; Hara, Kunio; Shiraishi, Masayuki [Fukuoka Univ. (Japan)

    1982-12-01

    An atypical case of Reye's syndrome was reported with emphasis on usefulness of CT for the diagnosis and follow-up study of this disease. The patient was a 13-month-old girl who had been transferred to our hospital because of status epilepticus, a comatous state and a high temperature. She was diagnosed as having Reye's syndrome according to data of liver function tests, findings in CSF and body CT which revealed swelling of the liver with diminished attenuation value suggesting fatty infiltration. However, there were atypical features in this patient: epileptic seizures since age 5 months, no vomiting at the time of onset and no evidence of brain swelling on CT in acute phase. She was discharged 2 months later with impaired neuropsychological functions of marked degree. When she was 2 year-old, she again went into status epilepticus, was comatous and had a high temperature. She was dead when she arrived at emergency room of our hospital. Autopsy findings revealed features of Reye's syndrome as follows: abundant accumulation of small fat droplets without nuclear displacement in the liver, fatty infiltration in the kidney and myocardium, and mild swelling in the cerebral cortex with marked ventricular dilatation. The possibility of recurrence of Reye's syndrome was discussed based on the clinical and autopsy findings. The value of CT in the diagnosis and the follow-up study of this disease was emphasized.

  8. Quantification of C2 cervical spine rotatory fixation by X-ray, MRI and CT

    International Nuclear Information System (INIS)

    Gradl, Georg; Maier-Bosse, Tamara; Staebler, Axel; Penning, Randolph

    2005-01-01

    Atlanto-axial rotatory displacement is known to be a cause of childhood torticollis and may as well be responsible for chronic neck pain after rear-end automobile collisions. The objective was to determine whether quantification of C2 malrotation is possible by plain radiographs in comparison to CT as the golden standard. MR imaging was evaluated as to whether it was of equal value in the detection of bony landmarks. C2 vertebra of five human cadaveric cervical spine specimens, ligamentously intact, were rotated using a Steinmann pin in steps of 5 up to 15 right and 15 left. Plain radiographs, CT and MRI images were taken in each rotational step. Data were analyzed for quantification of C2 rotation by three independent examiners. A rotation of 5 led to a spinous process deviation (SPD) from the midline of 3 mm as measured on an a.p. plain radiograph. A coefficient of rotation was calculated (1.62 mm -1 ). Data analyzed by three examiners revealed a small coefficient of variation (0.03). MRI and CT measurements showed comparable results for the quantification of rotation; however, in both techniques the 15 rotation was underestimated. Quantification of upper cervical spine malrotation was possible on plain radiographs using the SPD and a rotation coefficient. MRI and CT were equally successful in the assessment of C2 malrotation. (orig.)

  9. Hybrid Silk Fibers Dry-Spun from Regenerated Silk Fibroin/Graphene Oxide Aqueous Solutions.

    Science.gov (United States)

    Zhang, Chao; Zhang, Yaopeng; Shao, Huili; Hu, Xuechao

    2016-02-10

    Regenerated silk fibroin (RSF)/graphene oxide (GO) hybrid silk fibers were dry-spun from a mixed dope of GO suspension and RSF aqueous solution. It was observed that the presence of GO greatly affect the viscosity of RSF solution. The RSF/GO hybrid fibers showed from FTIR result lower β-sheet content compared to that of pure RSF fibers. The result of synchrotron radiation wide-angle X-ray diffraction showed that the addition of GO confined the crystallization of silk fibroin (SF) leading to the decrease of crystallinity, smaller crystallite size, and new formation of interphase zones in the artificial silks. Synchrotron radiation small-angle X-ray scattering also proved that GO sheets in the hybrid silks and blended solutions were coated with a certain thickness of interphase zones due to the complex interaction between the two components. A low addition of GO, together with the mesophase zones formed between GO and RSF, enhanced the mechanical properties of hybrid fibers. The highest breaking stress of the hybrid fibers reached 435.5 ± 71.6 MPa, 23% improvement in comparison to that of degummed silk and 72% larger than that of pure RSF silk fiber. The hybrid RSF/GO materials with good biocompatibility and enhanced mechanical properties may have potential applications in tissue engineering, bioelectronic devices, or energy storage.

  10. 5 CFR 330.706 - Notification of displaced employees.

    Science.gov (United States)

    2010-01-01

    ... 5 Administrative Personnel 1 2010-01-01 2010-01-01 false Notification of displaced employees. 330... RECRUITMENT, SELECTION, AND PLACEMENT (GENERAL) Interagency Career Transition Assistance Plan for Displaced Employees § 330.706 Notification of displaced employees. (a) In addition to meeting the requirements of...

  11. Peritoneal mesothelioma: CT and MRI findings

    International Nuclear Information System (INIS)

    Puvaneswary, M.; Chen, S.; Proietto, T.

    2002-01-01

    Two patients with histologically proven diagnosis of peritoneal mesothelioma are presented. Both patients had CT scans of the abdomen. The second patient was also examined with MRI. Although imaging findings are striking, they are non-specific and diagnosing peritoneal mesothelioma in the absence of pleural calcification or pleural plaque on chest radiograph or CT is difficult. However, it is possible to suggest the correct diagnosis in a patient with the presence of non-calcified omental and peritoneal infiltration or masses without liver secondaries or lymphadenopathy. Magnetic resonance imaging with its multi-planar capabilities is a highly sensitive non-invasive modality in the evaluation of malignant peritoneal mesothelioma and can demonstrate the exact site and clarify whether the mass is arising from the peritoneal surface or within a visceral organ. Copyright (2002) Blackwell Science Pty Ltd

  12. Measurement of mesothelioma on thoracic CT scans: A comparison of manual and computer-assisted techniques

    International Nuclear Information System (INIS)

    Armato, Samuel G. III; Oxnard, Geoffrey R.; MacMahon, Heber; Vogelzang, Nicholas J.; Kindler, Hedy L.; Kocherginsky, Masha; Starkey, Adam

    2004-01-01

    Our purpose in this study was to evaluate the variability of manual mesothelioma tumor thickness measurements in computed tomography (CT) scans and to assess the relative performance of six computerized measurement algorithms. The CT scans of 22 patients with malignant pleural mesothelioma were collected. In each scan, an initial observer identified up to three sites in each of three CT sections at which tumor thickness measurements were to be made. At each site, five observers manually measured tumor thickness through a computer interface. Three observers repeated these measurements during three separate sessions. Inter- and intra-observer variability in the manual measurement of tumor thickness was assessed. Six automated measurement algorithms were developed based on the geometric relationship between a specified measurement site and the automatically extracted lung regions. Computer-generated measurements were compared with manual measurements. The tumor thickness measurements of different observers were highly correlated (r≥0.99); however, the 95% limits of agreement for relative inter-observer difference spanned a range of 30%. Tumor thickness measurements generated by the computer algorithms also correlated highly with the average of observer measurements (r≥0.93). We have developed computerized techniques for the measurement of mesothelioma tumor thickness in CT scans. These techniques achieved varying levels of agreement with measurements made by human observers

  13. 40 CFR 205.153 - Engine displacement.

    Science.gov (United States)

    2010-07-01

    ..., in accordance with American Society for Testing Materials (ASTM) E 29-67. (b) For rotary engines... 40 Protection of Environment 24 2010-07-01 2010-07-01 false Engine displacement. 205.153 Section... TRANSPORTATION EQUIPMENT NOISE EMISSION CONTROLS Motorcycles § 205.153 Engine displacement. (a) Engine...

  14. Multi-site abdominal tuberculosis mimics malignancy on ~(18)F-FDG PET/CT:Report of three cases

    Institute of Scientific and Technical Information of China (English)

    2010-01-01

    18 F-fluorodeoxyglucose positron emission/computed tomography( 18 F-FDG PET/CT)imaging,an established procedure for evaluation of malignancy,shows an increased 18 F-FDG uptake in inflammatory conditions.We present three patients with abdominal pain and weight loss.Conventional imaging studies indicated that abdominal neoplasm and 18 F-FDG PET/CT for assessment of malignancy showed multiple lesions with intense 18 FFDG uptake in abdomen of the three cases.However,the three patients were finally diagnosed wit...

  15. Performance characterization of the PET-CT tomograph at the PET-cyclotron-radiochemistry site of Messina University

    OpenAIRE

    Amato, Ernesto; Baldari, Sergio; Tomasello, Francesco

    2015-01-01

    A PET-cyclotron-radiochemistry plant was built at Messina University Hospital, whose diagnostics section was equipped with a PET-CT scanner composed by a time of flight PET and a 16-slice CT. The present note reports about the results of tomograph's acceptance tests, which had been planned and carried out in order to verify the correspondence of the specific scanner's performances declared by the firm and the fulfillment of Italian law's minimal criteria of acceptability. Acceptance tests...

  16. Detection of esophageal fiducial marker displacement during radiation therapy with a 2-dimensional on-board imager: analysis of internal margin for esophageal cancer.

    Science.gov (United States)

    Fukada, Junichi; Hanada, Takashi; Kawaguchi, Osamu; Ohashi, Toshio; Takeuchi, Hiroya; Kitagawa, Yuko; Seki, Satoshi; Shiraishi, Yutaka; Ogata, Haruhiko; Shigematsu, Naoyuki

    2013-03-15

    To quantify the interfraction displacement of esophageal fiducial markers for primary esophageal cancer radiation therapy. Orthogonal 2-dimensional (2D) matching records fused to vertebrae were analyzed in clinically staged T1/2N0 esophageal cancer patients undergoing endoscopic clipping as fiducial metal markers. Displacement of the markers between the digitally reconstructed radiographs and on-board kilovoltage images during radiation therapy was analyzed according to direction and esophageal site. Forty-four patients, with 81 markers (10 proximal, 42 middle, and 29 distal), underwent 367 2D matching sessions during radiation therapy. The mean (SD) absolute marker displacement was 0.26 (0.30) cm in the right-left (RL), 0.50 (0.39) cm in the superior-inferior (SI), and 0.24 (0.21) cm in the anterior-posterior (AP) direction. Displacement was significantly larger in the SI than in the RL and AP directions (Pdisplacements of the distal, middle, and proximal esophagus were 0.67 (0.45) cm, 0.42 (0.32) cm, and 0.36 (0.30) cm, respectively. Distal esophagus displacement was significantly larger than those of the middle and proximal esophagus (Pinternal margin to cover 95% of the cases was 0.75 cm in the RL and AP directions. In the SI direction, the margin was 1.25 cm for the proximal and middle esophagus and 1.75 cm for the distal esophagus. The magnitude of interfraction displacement of esophageal clips was larger in the SI direction, particularly in the distal esophagus, but substantial displacement was observed in other directions and at other esophageal sites. It is practical to take estimated movements into account with internal margins, even if vertebrae-based 2D matching is performed. Copyright © 2013 Elsevier Inc. All rights reserved.

  17. Dissolved oxygen detection by galvanic displacement-induced

    Indian Academy of Sciences (India)

    Dissolved oxygen detection by galvanic displacement-induced graphene/silver nanocomposite ... dissolved oxygen (DO) detection based on a galvanic displacement synthesized reduced graphene oxide–silver nanoparticles ... Current Issue

  18. Performance characterization of the PET-CT tomograph at the PET-cyclotron-radiochemistry site of Messina University

    Directory of Open Access Journals (Sweden)

    Ernesto Amato

    2015-10-01

    Full Text Available A PET-cyclotron-radiochemistry plant was built at Messina University Hospital, whose diagnostics section was equipped with a PET-CT scanner composed by a time of flight PET and a 16-slice CT. The present note reports about the results of tomograph's acceptance tests, which had been planned and carried out in order to verify the correspondence of the specific scanner's performances declared by the firm and the fulfillment of Italian law's minimal criteria of acceptability. Acceptance tests gave positive results for all the physical parameters measured. The assessment of CT slice thickness, with regard to the thinner slices of 0.75 and 0.6 mm, required the employment of a manual procedure exploiting a phantom equipped with low inclination ramps. These results allowed us to assess a baseline of performance parameters to be taken as a reference for periodic constance tests.

  19. 4 T MRI of chondrocalcinosis in combination with three-dimensional CT, radiography, and arthroscopy: a report of three cases

    International Nuclear Information System (INIS)

    Suan, J.C.; Chhem, R.K.; Gati, J.S.; Norley, C.J.; Holdsworth, D.W.

    2005-01-01

    To describe 4 T MRI techniques in imaging chondrocalcinosis within the knee and examine the results together with those demonstrated using three-dimensional (3D) computed tomography, conventional radiography, and arthroscopy. From a larger clinical imaging study of early osteoarthritis, knee arthroscopy patients were imaged using high-field MRI and high-resolution 3D CT prior to their surgery. Retrospective review of the imaging data diagnosed three patients with chondrocalcinosis. Fat-suppressed 3D spoiled gradient (3D SPGR) and two-dimensional fat-suppressed fast spin echo (FSE) imaging was performed at 4 T. The MR images, multi-planar reformatted CT (MPR-CT) and maximum intensity projection CT (MIP-CT) images, and radiographs were examined by a musculoskeletal radiologist for the presence and location of chondrocalcinosis. The findings from arthroscopy were also included. MRI showed 16 sites of punctate hypointense regions from 18 articular surfaces and five of six menisci with similar signal characteristics. Both meniscal chondrocalcinosis and meniscal tears were clearly visible using the 3D SPGR sequence. Only three sites were demonstrated to have calcification using MPR-CT and MIP-CT revealed an additional three. In articular cartilage surfaces showing surface disruption, arthroscopy demonstrated 11 sites with crystal deposition. Arthroscopy also revealed five menisci with calcification present. Our preliminary findings suggest that imaging chondrocalcinosis using spoiled gradient 4 T MRI is superior and complementary to the other imaging modalities in the detection of crystal deposition in both articular cartilage and menisci. (orig.)

  20. 4 T MRI of chondrocalcinosis in combination with three-dimensional CT, radiography, and arthroscopy: a report of three cases

    Energy Technology Data Exchange (ETDEWEB)

    Suan, J.C.; Chhem, R.K.; Gati, J.S.; Norley, C.J.; Holdsworth, D.W. [Robarts Research Institute, Imaging Research Laboratories, London, Ontario (Canada)

    2005-11-01

    To describe 4 T MRI techniques in imaging chondrocalcinosis within the knee and examine the results together with those demonstrated using three-dimensional (3D) computed tomography, conventional radiography, and arthroscopy. From a larger clinical imaging study of early osteoarthritis, knee arthroscopy patients were imaged using high-field MRI and high-resolution 3D CT prior to their surgery. Retrospective review of the imaging data diagnosed three patients with chondrocalcinosis. Fat-suppressed 3D spoiled gradient (3D SPGR) and two-dimensional fat-suppressed fast spin echo (FSE) imaging was performed at 4 T. The MR images, multi-planar reformatted CT (MPR-CT) and maximum intensity projection CT (MIP-CT) images, and radiographs were examined by a musculoskeletal radiologist for the presence and location of chondrocalcinosis. The findings from arthroscopy were also included. MRI showed 16 sites of punctate hypointense regions from 18 articular surfaces and five of six menisci with similar signal characteristics. Both meniscal chondrocalcinosis and meniscal tears were clearly visible using the 3D SPGR sequence. Only three sites were demonstrated to have calcification using MPR-CT and MIP-CT revealed an additional three. In articular cartilage surfaces showing surface disruption, arthroscopy demonstrated 11 sites with crystal deposition. Arthroscopy also revealed five menisci with calcification present. Our preliminary findings suggest that imaging chondrocalcinosis using spoiled gradient 4 T MRI is superior and complementary to the other imaging modalities in the detection of crystal deposition in both articular cartilage and menisci. (orig.)