WorldWideScience

Sample records for single-step electronic detection

  1. Production of the Q2 doubly excited states of the hydrogen molecule by electron impact in a single step

    Science.gov (United States)

    Santos, Leonardo O.; Rocha, Alexandre B.; Faria, Nelson Velho de Castro; Jalbert, Ginette

    2017-03-01

    We calculate the single step cross sections for excitation of Q 2 states of H2 and its subsequent dissociation. The cross section calculations were performed within the first Born approximation and the electronic wave functions were obtained via State-Averaged Multiconfigurational Self-Consistent Field followed by Configuration Interaction. We have assumed autoionization is the only important process competing with dissociation into neutral atoms. We have estimated its probability through a semi classical approach and compared with results of literature. Special attention was given to the Q 2 1Σg +(1) state which, as has been shown in a previous work, may dissociate into H(2 sσ) + H(2 sσ) fragments (some figures in this article are in colour only in the electronic version).

  2. Development of single step RT-PCR for detection of Kyasanur forest disease virus from clinical samples

    Directory of Open Access Journals (Sweden)

    Gouri Chaubal

    2018-02-01

    Discussion and conclusion: The previously published sensitive real time RT-PCR assay requires higher cost in terms of reagents and machine setup and technical expertise has been the primary reason for development of this assay. A single step RT-PCR is relatively easy to perform and more cost effective than real time RT-PCR in smaller setups in the absence of Biosafety Level-3 facility. This study reports the development and optimization of single step RT-PCR assay which is more sensitive and less time-consuming than nested RT-PCR and cost effective for rapid diagnosis of KFD viral RNA.

  3. Single-Step versus Stepwise Two-Electron Reduction of Polyarylpyridiniums: Insights from the Steric Switching of Redox Potential Compression

    Czech Academy of Sciences Publication Activity Database

    Fortage, J.; Peltier, C.; Perruchot, Ch.; Takemoto, Y.; Teki, Y.; Bedioui, F.; Marvand, V.; Dupeyre, G.; Pospíšil, Lubomír; Adamo, C.; Hromadová, Magdaléna; Ciofini, I.; Lainé, P. P.

    2012-01-01

    Roč. 134, č. 5 (2012), s. 2691-2705 ISSN 0002-7863 Institutional research plan: CEZ:AV0Z40400503 Keywords : FUNCTIONALIZED TERPYRIDYL LIGANDS * GATED PHOTOINDUCED PROCESSES * ONE-ELECTRON REDUCTION Subject RIV: CG - Electrochemistry Impact factor: 10.677, year: 2012

  4. Detection of 22 common leukemic fusion genes using a single-step multiplex qRT-PCR-based assay.

    Science.gov (United States)

    Lyu, Xiaodong; Wang, Xianwei; Zhang, Lina; Chen, Zhenzhu; Zhao, Yu; Hu, Jieying; Fan, Ruihua; Song, Yongping

    2017-07-25

    Fusion genes generated from chromosomal translocation play an important role in hematological malignancies. Detection of fusion genes currently employ use of either conventional RT-PCR methods or fluorescent in situ hybridization (FISH), where both methods involve tedious methodologies and require prior characterization of chromosomal translocation events as determined by cytogenetic analysis. In this study, we describe a real-time quantitative reverse transcription PCR (qRT-PCR)-based multi-fusion gene screening method with the capacity to detect 22 fusion genes commonly found in leukemia. This method does not require pre-characterization of gene translocation events, thereby facilitating immediate diagnosis and therapeutic management. We performed fluorescent qRT-PCR (F-qRT-PCR) using a commercially-available multi-fusion gene detection kit on a patient cohort of 345 individuals comprising 108 cases diagnosed with acute myeloid leukemia (AML) for initial evaluation; remaining patients within the cohort were assayed for confirmatory diagnosis. Results obtained by F-qRT-PCR were compared alongside patient analysis by cytogenetic characterization. Gene translocations detected by F-qRT-PCR in AML cases were diagnosed in 69.4% of the patient cohort, which was comparatively similar to 68.5% as diagnosed by cytogenetic analysis, thereby demonstrating 99.1% concordance. Overall gene fusion was detected in 53.7% of the overall patient population by F-qRT-PCR, 52.9% by cytogenetic prediction in leukemia, and 9.1% in non-leukemia patients by both methods. The overall concordance rate was calculated to be 99.0%. Fusion genes were detected by F-qRT-PCR in 97.3% of patients with CML, followed by 69.4% with AML, 33.3% with acute lymphoblastic leukemia (ALL), 9.1% with myelodysplastic syndromes (MDS), and 0% with chronic lymphocytic leukemia (CLL). We describe the use of a F-qRT-PCR-based multi-fusion gene screening method as an efficient one-step diagnostic procedure as an

  5. A rapid, ratiometric, enzyme-free, and sensitive single-step miRNA detection using three-way junction based FRET probes

    Science.gov (United States)

    Luo, Qingying; Liu, Lin; Yang, Cai; Yuan, Jing; Feng, Hongtao; Chen, Yan; Zhao, Peng; Yu, Zhiqiang; Jin, Zongwen

    2018-03-01

    MicroRNAs (miRNAs) are single stranded endogenous molecules composed of only 18-24 nucleotides which are critical for gene expression regulating the translation of messenger RNAs. Conventional methods based on enzyme-assisted nucleic acid amplification techniques have many problems, such as easy contamination, high cost, susceptibility to false amplification, and tendency to have sequence mismatches. Here we report a rapid, ratiometric, enzyme-free, sensitive, and highly selective single-step miRNA detection using three-way junction assembled (or self-assembled) FRET probes. The developed strategy can be operated within the linear range from subnanomolar to hundred nanomolar concentrations of miRNAs. In comparison with the traditional approaches, our method showed high sensitivity for the miRNA detection and extreme selectivity for the efficient discrimination of single-base mismatches. The results reveal that the strategy paved a new avenue for the design of novel highly specific probes applicable in diagnostics and potentially in microscopic imaging of miRNAs in real biological environments.

  6. Development and Evaluation of a Single-Step Duplex PCR for Simultaneous Detection of Fasciola hepatica and Fasciola gigantica (Family Fasciolidae, Class Trematoda, Phylum Platyhelminthes)

    Science.gov (United States)

    Nguyen, Khue Thi; Nguyen, Nga Thi Bich; Doan, Huong Thi Thanh; Le, Xuyen Thi Kim; Hoang, Chau Thi Minh; De, Nguyen Van

    2012-01-01

    A single-step multiplex PCR (here referred to as a duplex PCR) has been developed for simultaneous detection and diagnosis of Fasciola hepatica and F. gigantica. These species overlap in distribution in many countries of North and East Africa and Central and Southeast Asia and are similar in egg morphology, making identification from fecal samples difficult. Based on a comparative alignment of mitochondrial DNA (mtDNA) spanning the region of cox1-trnT-rrnL, two species-specific forward primers were designed, FHF (for F. hepatica) and FGF (for F. gigantica), and a single reverse primer, FHGR (common for both species). Conventional PCR followed by sequencing was applied using species-specific primer pairs to verify the specificity of primers and the identity of Fasciola DNA templates. Duplex PCR (using three primers) was used for testing with the DNA extracted from adult worms, miracidia, and eggs, producing amplicons of 1,031 bp for F. hepatica and 615 bp for F. gigantica. The duplex PCR failed to amplify from DNA of other common liver and intestinal trematodes, including two opisthorchiids, three heterophyids, an echinostomid, another fasciolid, and a taeniid cestode. The sensitivity assay showed that the duplex PCR limit of detection for each Fasciola species was between 0.012 ng and 0.006 ng DNA. Evaluation using DNA templates from 32 Fasciola samples (28 adults and 4 eggs) and from 25 field-collected stools of ruminants and humans revealed specific bands of the correct size and the presence of Fasciola species. This novel mtDNA duplex PCR is a sensitive and fast tool for accurate identification of Fasciola species in areas of distributional and zonal overlap. PMID:22692744

  7. Development and evaluation of a single-step duplex PCR for simultaneous detection of Fasciola hepatica and Fasciola gigantica (family Fasciolidae, class Trematoda, phylum Platyhelminthes).

    Science.gov (United States)

    Le, Thanh Hoa; Nguyen, Khue Thi; Nguyen, Nga Thi Bich; Doan, Huong Thi Thanh; Le, Xuyen Thi Kim; Hoang, Chau Thi Minh; De, Nguyen Van

    2012-08-01

    A single-step multiplex PCR (here referred to as a duplex PCR) has been developed for simultaneous detection and diagnosis of Fasciola hepatica and F. gigantica. These species overlap in distribution in many countries of North and East Africa and Central and Southeast Asia and are similar in egg morphology, making identification from fecal samples difficult. Based on a comparative alignment of mitochondrial DNA (mtDNA) spanning the region of cox1-trnT-rrnL, two species-specific forward primers were designed, FHF (for F. hepatica) and FGF (for F. gigantica), and a single reverse primer, FHGR (common for both species). Conventional PCR followed by sequencing was applied using species-specific primer pairs to verify the specificity of primers and the identity of Fasciola DNA templates. Duplex PCR (using three primers) was used for testing with the DNA extracted from adult worms, miracidia, and eggs, producing amplicons of 1,031 bp for F. hepatica and 615 bp for F. gigantica. The duplex PCR failed to amplify from DNA of other common liver and intestinal trematodes, including two opisthorchiids, three heterophyids, an echinostomid, another fasciolid, and a taeniid cestode. The sensitivity assay showed that the duplex PCR limit of detection for each Fasciola species was between 0.012 ng and 0.006 ng DNA. Evaluation using DNA templates from 32 Fasciola samples (28 adults and 4 eggs) and from 25 field-collected stools of ruminants and humans revealed specific bands of the correct size and the presence of Fasciola species. This novel mtDNA duplex PCR is a sensitive and fast tool for accurate identification of Fasciola species in areas of distributional and zonal overlap.

  8. Single-step electron transfer on the nanometer scale: ultra-fast charge shift in strongly coupled zinc porphyrin-gold porphyrin dyads.

    Science.gov (United States)

    Fortage, Jérôme; Boixel, Julien; Blart, Errol; Hammarström, Leif; Becker, Hans Christian; Odobel, Fabrice

    2008-01-01

    The synthesis, electrochemical properties, and photoinduced electron transfer processes of a series of three novel zinc(II)-gold(III) bisporphyrin dyads (ZnP--S--AuP(+)) are described. The systems studied consist of two trisaryl porphyrins connected directly in the meso position via an alkyne unit to tert-(phenylenethynylene) or penta(phenylenethynylene) spacers. In these dyads, the estimated center to center interporphyrin separation distance varies from 32 to 45 A. The absorption, emission, and electrochemical data indicate that there are strong electronic interactions between the linked elements, thanks to the direct attachment of the spacer on the porphyrin ring through the alkyne unit. At room temperature in toluene, light excitation of the zinc porphyrin results in almost quantitative formation of the charge shifted state (.+)ZnP--S--AuP(.), whose lifetime is in the order of hundreds of picoseconds. In this solvent, the charge-separated state decays to the ground state through the intermediate population of the zinc porphyrin triplet excited state. Excitation of the gold porphyrin leads instead to rapid energy transfer to the triplet ZnP. In dichloromethane the charge shift reactions are even faster, with time constants down to 2 ps, and may be induced also by excitation of the gold porphyrin. In this latter solvent, the longest charge-shifted lifetime (tau=2.3 ns) was obtained with the penta-(phenylenethynylene) spacer. The charge shift reactions are discussed in terms of bridge-mediated super-exchange mechanisms as electron or hole transfer. These new bis-porphyrin arrays, with strong electronic coupling, represent interesting molecular systems in which extremely fast and efficient long-range photoinduced charge shift occurs over a long distance. The rate constants are two to three orders of magnitude larger than for corresponding ZnP--AuP(+) dyads linked via meso-phenyl groups to oligo-phenyleneethynylene spacers. This study demonstrates the critical

  9. Quantitative secondary electron detection

    Science.gov (United States)

    Agrawal, Jyoti; Joy, David C.; Nayak, Subuhadarshi

    2018-05-08

    Quantitative Secondary Electron Detection (QSED) using the array of solid state devices (SSD) based electron-counters enable critical dimension metrology measurements in materials such as semiconductors, nanomaterials, and biological samples (FIG. 3). Methods and devices effect a quantitative detection of secondary electrons with the array of solid state detectors comprising a number of solid state detectors. An array senses the number of secondary electrons with a plurality of solid state detectors, counting the number of secondary electrons with a time to digital converter circuit in counter mode.

  10. Considering dominance in reduced single-step genomic evaluations.

    Science.gov (United States)

    Ertl, J; Edel, C; Pimentel, E C G; Emmerling, R; Götz, K-U

    2018-06-01

    Single-step models including dominance can be an enormous computational task and can even be prohibitive for practical application. In this study, we try to answer the question whether a reduced single-step model is able to estimate breeding values of bulls and breeding values, dominance deviations and total genetic values of cows with acceptable quality. Genetic values and phenotypes were simulated (500 repetitions) for a small Fleckvieh pedigree consisting of 371 bulls (180 thereof genotyped) and 553 cows (40 thereof genotyped). This pedigree was virtually extended for 2,407 non-genotyped daughters. Genetic values were estimated with the single-step model and with different reduced single-step models. Including more relatives of genotyped cows in the reduced single-step model resulted in a better agreement of results with the single-step model. Accuracies of genetic values were largest with single-step and smallest with reduced single-step when only the cows genotyped were modelled. The results indicate that a reduced single-step model is suitable to estimate breeding values of bulls and breeding values, dominance deviations and total genetic values of cows with acceptable quality. © 2018 Blackwell Verlag GmbH.

  11. Single-step fabrication of quantum funnels via centrifugal colloidal casting of nanoparticle films.

    KAUST Repository

    Kim, Jin Young; Adinolfi, Valerio; Sutherland, Brandon R; Voznyy, Oleksandr; Kwon, S Joon; Kim, Tae Wu; Kim, Jeongho; Ihee, Hyotcherl; Kemp, Kyle; Adachi, Michael; Yuan, Mingjian; Kramer, Illan; Zhitomirsky, David; Hoogland, Sjoerd; Sargent, Edward H

    2015-01-01

    Centrifugal casting of composites and ceramics has been widely employed to improve the mechanical and thermal properties of functional materials. This powerful method has yet to be deployed in the context of nanoparticles--yet size-effect tuning of quantum dots is among their most distinctive and application-relevant features. Here we report the first gradient nanoparticle films to be constructed in a single step. By creating a stable colloid of nanoparticles that are capped with electronic-conduction-compatible ligands we were able to leverage centrifugal casting for thin-films devices. This new method, termed centrifugal colloidal casting, is demonstrated to form films in a bandgap-ordered manner with efficient carrier funnelling towards the lowest energy layer. We constructed the first quantum-gradient photodiode to be formed in a single deposition step and, as a result of the gradient-enhanced electric field, experimentally measured the highest normalized detectivity of any colloidal quantum dot photodetector.

  12. Single-step fabrication of quantum funnels via centrifugal colloidal casting of nanoparticle films

    Science.gov (United States)

    Kim, Jin Young; Adinolfi, Valerio; Sutherland, Brandon R.; Voznyy, Oleksandr; Kwon, S. Joon; Kim, Tae Wu; Kim, Jeongho; Ihee, Hyotcherl; Kemp, Kyle; Adachi, Michael; Yuan, Mingjian; Kramer, Illan; Zhitomirsky, David; Hoogland, Sjoerd; Sargent, Edward H.

    2015-01-01

    Centrifugal casting of composites and ceramics has been widely employed to improve the mechanical and thermal properties of functional materials. This powerful method has yet to be deployed in the context of nanoparticles—yet size–effect tuning of quantum dots is among their most distinctive and application-relevant features. Here we report the first gradient nanoparticle films to be constructed in a single step. By creating a stable colloid of nanoparticles that are capped with electronic-conduction-compatible ligands we were able to leverage centrifugal casting for thin-films devices. This new method, termed centrifugal colloidal casting, is demonstrated to form films in a bandgap-ordered manner with efficient carrier funnelling towards the lowest energy layer. We constructed the first quantum-gradient photodiode to be formed in a single deposition step and, as a result of the gradient-enhanced electric field, experimentally measured the highest normalized detectivity of any colloidal quantum dot photodetector. PMID:26165185

  13. Single-step fabrication of quantum funnels via centrifugal colloidal casting of nanoparticle films.

    KAUST Repository

    Kim, Jin Young

    2015-07-13

    Centrifugal casting of composites and ceramics has been widely employed to improve the mechanical and thermal properties of functional materials. This powerful method has yet to be deployed in the context of nanoparticles--yet size-effect tuning of quantum dots is among their most distinctive and application-relevant features. Here we report the first gradient nanoparticle films to be constructed in a single step. By creating a stable colloid of nanoparticles that are capped with electronic-conduction-compatible ligands we were able to leverage centrifugal casting for thin-films devices. This new method, termed centrifugal colloidal casting, is demonstrated to form films in a bandgap-ordered manner with efficient carrier funnelling towards the lowest energy layer. We constructed the first quantum-gradient photodiode to be formed in a single deposition step and, as a result of the gradient-enhanced electric field, experimentally measured the highest normalized detectivity of any colloidal quantum dot photodetector.

  14. Factors affecting GEBV accuracy with single-step Bayesian models.

    Science.gov (United States)

    Zhou, Lei; Mrode, Raphael; Zhang, Shengli; Zhang, Qin; Li, Bugao; Liu, Jian-Feng

    2018-01-01

    A single-step approach to obtain genomic prediction was first proposed in 2009. Many studies have investigated the components of GEBV accuracy in genomic selection. However, it is still unclear how the population structure and the relationships between training and validation populations influence GEBV accuracy in terms of single-step analysis. Here, we explored the components of GEBV accuracy in single-step Bayesian analysis with a simulation study. Three scenarios with various numbers of QTL (5, 50, and 500) were simulated. Three models were implemented to analyze the simulated data: single-step genomic best linear unbiased prediction (GBLUP; SSGBLUP), single-step BayesA (SS-BayesA), and single-step BayesB (SS-BayesB). According to our results, GEBV accuracy was influenced by the relationships between the training and validation populations more significantly for ungenotyped animals than for genotyped animals. SS-BayesA/BayesB showed an obvious advantage over SSGBLUP with the scenarios of 5 and 50 QTL. SS-BayesB model obtained the lowest accuracy with the 500 QTL in the simulation. SS-BayesA model was the most efficient and robust considering all QTL scenarios. Generally, both the relationships between training and validation populations and LD between markers and QTL contributed to GEBV accuracy in the single-step analysis, and the advantages of single-step Bayesian models were more apparent when the trait is controlled by fewer QTL.

  15. Remote detection of electronic devices

    Science.gov (United States)

    Judd, Stephen L [Los Alamos, NM; Fortgang, Clifford M [Los Alamos, NM; Guenther, David C [Los Alamos, NM

    2012-09-25

    An apparatus and method for detecting solid-state electronic devices are described. Non-linear junction detection techniques are combined with spread-spectrum encoding and cross correlation to increase the range and sensitivity of the non-linear junction detection and to permit the determination of the distances of the detected electronics. Nonlinear elements are detected by transmitting a signal at a chosen frequency and detecting higher harmonic signals that are returned from responding devices.

  16. Single-step affinity purification for fungal proteomics.

    Science.gov (United States)

    Liu, Hui-Lin; Osmani, Aysha H; Ukil, Leena; Son, Sunghun; Markossian, Sarine; Shen, Kuo-Fang; Govindaraghavan, Meera; Varadaraj, Archana; Hashmi, Shahr B; De Souza, Colin P; Osmani, Stephen A

    2010-05-01

    A single-step protein affinity purification protocol using Aspergillus nidulans is described. Detailed protocols for cell breakage, affinity purification, and depending on the application, methods for protein release from affinity beads are provided. Examples defining the utility of the approaches, which should be widely applicable, are included.

  17. Single-Step Affinity Purification for Fungal Proteomics ▿ †

    OpenAIRE

    Liu, Hui-Lin; Osmani, Aysha H.; Ukil, Leena; Son, Sunghun; Markossian, Sarine; Shen, Kuo-Fang; Govindaraghavan, Meera; Varadaraj, Archana; Hashmi, Shahr B.; De Souza, Colin P.; Osmani, Stephen A.

    2010-01-01

    A single-step protein affinity purification protocol using Aspergillus nidulans is described. Detailed protocols for cell breakage, affinity purification, and depending on the application, methods for protein release from affinity beads are provided. Examples defining the utility of the approaches, which should be widely applicable, are included.

  18. Percutaneous Cystgastrostomy as a Single-Step Procedure

    International Nuclear Information System (INIS)

    Curry, L.; Sookur, P.; Low, D.; Bhattacharya, S.; Fotheringham, T.

    2009-01-01

    The purpose of this study was to evaluate the success of percutaneous transgastric cystgastrostomy as a single-step procedure. We performed a retrospective analysis of single-step percutaneous transgastric cystgastrostomy carried out in 12 patients (8 male, 4 female; mean age 44 years; range 21-70 years), between 2002 and 2007, with large symptomatic pancreatic pseudocysts for whom up to 1-year follow-up data (mean 10 months) were available. All pseudocysts were drained by single-step percutaneous cystgastrostomy with the placement of either one or two stents. The procedure was completed successfully in all 12 patients. The pseudocysts showed complete resolution on further imaging in 7 of 12 patients with either enteric passage of the stent or stent removal by endoscopy. In 2 of 12 patients, the pseudocysts showed complete resolution on imaging, with the stents still noted in situ. In 2 of 12 patients, the pseudocysts became infected after 1 month and required surgical intervention. In 1 of 12 patients, the pseudocyst showed partial resolution on imaging, but subsequently reaccumulated and later required external drainage. In our experience, percutaneous cystgastrostomy as a single-step procedure has a high success rate and good short-term outcomes over 1-year follow-up and should be considered in the treatment of large symptomatic cysts.

  19. Single-step electrochemical method for producing very sharp Au scanning tunneling microscopy tips

    International Nuclear Information System (INIS)

    Gingery, David; Buehlmann, Philippe

    2007-01-01

    A single-step electrochemical method for making sharp gold scanning tunneling microscopy tips is described. 3.0M NaCl in 1% perchloric acid is compared to several previously reported etchants. The addition of perchloric acid to sodium chloride solutions drastically shortens etching times and is shown by transmission electron microscopy to produce very sharp tips with a mean radius of curvature of 15 nm

  20. Antibacterial and cytocompatible nanotextured Ti surface incorporating silver via single step hydrothermal processing

    Energy Technology Data Exchange (ETDEWEB)

    Mohandas, Anu; Krishnan, Amit G.; Biswas, Raja; Menon, Deepthy, E-mail: deepthymenon@aims.amrita.edu; Nair, Manitha B., E-mail: manithanair@aims.amrita.edu

    2017-06-01

    Nanosurface modification of Titanium (Ti) implants and prosthesis is proved to enhance osseointegration at the tissue–implant interface. However, many of these products lack adequate antibacterial capability, which leads to implant loosening. As a curative strategy, in this study, nanotextured Ti substrates embedded with silver nanoparticles were developed through a single step hydrothermal processing in an alkaline medium containing silver nitrate at different concentrations (15, 30 and 75 μM). Scanning electron micrographs revealed a non-periodically oriented nanoleafy structure on Ti (TNL) decorated with Ag nanoparticles (nanoAg), which was verified by XPS, XRD and EDS analysis. This TNLAg substrate proved to be mechanically stable upon nanoindentation and nanoscratch tests. Silver ions at detectable levels were released for a period of ~ 28 days only from substrates incorporating higher nanoAg content. The samples demonstrated antibacterial activity towards both Escherichia coli and Staphylococcus aureus, with a more favorable response to the former. Simultaneously, Ti substrates incorporating nanoAg at all concentrations supported the viability, proliferation and osteogenic differentiation of mesenchymal stem cells. Overall, nanoAg incorporation into surface modified Ti via a simple one-step thermochemical method is a favorable strategy for producing implants with dual characteristics of antibacterial activity and cell compatibility. - Highlights: • Nanosilver was incorporated within Ti nanoleafy topography by simple one-step thermochemical method • The nanosurface demonstrated antibacterial activity against gram positive and gram negative bacteria • The nanosurface promoted the viability, proliferation and osteogenic differentiation of mesenchymal stem cells.

  1. Analog electronics for radiation detection

    CERN Document Server

    2016-01-01

    Analog Electronics for Radiation Detection showcases the latest advances in readout electronics for particle, or radiation, detectors. Featuring chapters written by international experts in their respective fields, this authoritative text: Defines the main design parameters of front-end circuitry developed in microelectronics technologies Explains the basis for the use of complementary metal oxide semiconductor (CMOS) image sensors for the detection of charged particles and other non-consumer applications Delivers an in-depth review of analog-to-digital converters (ADCs), evaluating the pros and cons of ADCs integrated at the pixel, column, and per-chip levels Describes incremental sigma delta ADCs, time-to-digital converter (TDC) architectures, and digital pulse-processing techniques complementary to analog processing Examines the fundamental parameters and front-end types associated with silicon photomultipliers used for single visible-light photon detection Discusses pixel sensors ...

  2. Real-time, single-step bioassay using nanoplasmonic resonator with ultra-high sensitivity

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Xiang; Ellman, Jonathan A; Chen, Fanqing Frank; Su, Kai-Hang; Wei, Qi-Huo; Sun, Cheng

    2014-04-01

    A nanoplasmonic resonator (NPR) comprising a metallic nanodisk with alternating shielding layer(s), having a tagged biomolecule conjugated or tethered to the surface of the nanoplasmonic resonator for highly sensitive measurement of enzymatic activity. NPRs enhance Raman signals in a highly reproducible manner, enabling fast detection of protease and enzyme activity, such as Prostate Specific Antigen (paPSA), in real-time, at picomolar sensitivity levels. Experiments on extracellular fluid (ECF) from paPSA-positive cells demonstrate specific detection in a complex bio-fluid background in real-time single-step detection in very small sample volumes.

  3. Single step synthesis, characterization and applications of curcumin functionalized iron oxide magnetic nanoparticles

    Energy Technology Data Exchange (ETDEWEB)

    Bhandari, Rohit; Gupta, Prachi; Dziubla, Thomas; Hilt, J. Zach, E-mail: zach.hilt@uky.edu

    2016-10-01

    Magnetic iron oxide nanoparticles have been well known for their applications in magnetic resonance imaging (MRI), hyperthermia, targeted drug delivery, etc. The surface modification of these magnetic nanoparticles has been explored extensively to achieve functionalized materials with potential application in biomedical, environmental and catalysis field. Herein, we report a novel and versatile single step methodology for developing curcumin functionalized magnetic Fe{sub 3}O{sub 4} nanoparticles without any additional linkers, using a simple coprecipitation technique. The magnetic nanoparticles (MNPs) were characterized using transmission electron microscopy, X-ray diffraction, fourier transform infrared spectroscopy and thermogravimetric analysis. The developed MNPs were employed in a cellular application for protection against an inflammatory agent, a polychlorinated biphenyl (PCB) molecule. - Graphical abstract: Novel single step curcumin coated magnetic Fe{sub 3}O{sub 4} nanoparticles without any additional linkers for medical, environmental, and other applications. Display Omitted - Highlights: • A novel and versatile single step methodology for developing curcumin functionalized magnetic Fe{sub 3}O{sub 4} nanoparticles is reported. • The magnetic nanoparticles (MNPs) were characterized using TEM, XRD, FTIR and TGA. • The developed MNPs were employed in a cellular application for protection against an inflammatory agent, a polychlorinated biphenyl (PCB).

  4. Single step radiolytic synthesis of iridium nanoparticles onto graphene oxide

    International Nuclear Information System (INIS)

    Rojas, J.V.; Molina Higgins, M.C.; Toro Gonzalez, M.; Castano, C.E.

    2015-01-01

    Graphical abstract: - Highlights: • Ir nanoparticles were synthesized through a single step gamma irradiation process. • Homogeneously distributed Ir nanoparticles on graphene oxide are ∼2.3 nm in size. • Ir−O bonds evidenced the interaction of the nanoparticles with the support. - Abstract: In this work a new approach to synthesize iridium nanoparticles on reduced graphene oxide is presented. The nanoparticles were directly deposited and grown on the surface of the carbon-based support using a single step reduction method through gamma irradiation. In this process, an aqueous isopropanol solution containing the iridium precursor, graphene oxide, and sodium dodecyl sulfate was initially prepared and sonicated thoroughly to obtain a homogeneous dispersion. The samples were irradiated with gamma rays with energies of 1.17 and 1.33 MeV emitted from the spontaneous decay of the 60 Co irradiator. The interaction of gamma rays with water in the presence of isopropanol generates highly reducing species homogeneously distributed in the solution that can reduce the Ir precursor down to a zero valence state. An absorbed dose of 60 kGy was used, which according to the yield of reducing species is sufficient to reduce the total amount of precursor present in the solution. This novel approach leads to the formation of 2.3 ± 0.5 nm Ir nanoparticles distributed along the surface of the support. The oxygenated functionalities of graphene oxide served as nucleation sites for the formation of Ir nuclei and their subsequent growth. XPS results revealed that the interaction of Ir with the support occurs through Ir−O bonds.

  5. Virtual substitution scan via single-step free energy perturbation.

    Science.gov (United States)

    Chiang, Ying-Chih; Wang, Yi

    2016-02-05

    With the rapid expansion of our computing power, molecular dynamics (MD) simulations ranging from hundreds of nanoseconds to microseconds or even milliseconds have become increasingly common. The majority of these long trajectories are obtained from plain (vanilla) MD simulations, where no enhanced sampling or free energy calculation method is employed. To promote the 'recycling' of these trajectories, we developed the Virtual Substitution Scan (VSS) toolkit as a plugin of the open-source visualization and analysis software VMD. Based on the single-step free energy perturbation (sFEP) method, VSS enables the user to post-process a vanilla MD trajectory for a fast free energy scan of substituting aryl hydrogens by small functional groups. Dihedrals of the functional groups are sampled explicitly in VSS, which improves the performance of the calculation and is found particularly important for certain groups. As a proof-of-concept demonstration, we employ VSS to compute the solvation free energy change upon substituting the hydrogen of a benzene molecule by 12 small functional groups frequently considered in lead optimization. Additionally, VSS is used to compute the relative binding free energy of four selected ligands of the T4 lysozyme. Overall, the computational cost of VSS is only a fraction of the corresponding multi-step FEP (mFEP) calculation, while its results agree reasonably well with those of mFEP, indicating that VSS offers a promising tool for rapid free energy scan of small functional group substitutions. This article is protected by copyright. All rights reserved. © 2016 Wiley Periodicals, Inc.

  6. Electronic detecting equipment in the Camac standard

    International Nuclear Information System (INIS)

    Basiladze, S.G.

    1981-01-01

    Basic tends of development of electron detecting equipment of modern facilities for experiments in nuclear physics are considered. Special attention is paid to developments of specialized hybrid integrated circuits, specialized processors for selection of events, usage of integrated circuits of memories in detecting units as well as to prospects of developing nuclear electronics standards [ru

  7. Comparison of Model Reliabilities from Single-Step and Bivariate Blending Methods

    DEFF Research Database (Denmark)

    Taskinen, Matti; Mäntysaari, Esa; Lidauer, Martin

    2013-01-01

    Model based reliabilities in genetic evaluation are compared between three methods: animal model BLUP, single-step BLUP, and bivariate blending after genomic BLUP. The original bivariate blending is revised in this work to better account animal models. The study data is extracted from...... be calculated. Model reliabilities by the single-step and the bivariate blending methods were higher than by animal model due to genomic information. Compared to the single-step method, the bivariate blending method reliability estimates were, in general, lower. Computationally bivariate blending method was......, on the other hand, lighter than the single-step method....

  8. AN EFFICIENT ANALYSIS FOR ABSORPTION AND GAIN COEFFICIENTS IN 'SINGLE STEP-INDEX WAVEGUIDE'S BY USING THE ALPHA METHOD

    Directory of Open Access Journals (Sweden)

    Mustafa TEMİZ

    2008-02-01

    Full Text Available In this study, some design parameters such as normalized frequency and especially normalized propagation constant have been obtained, depending on some parameters which are functions of energy eigenvalues of the carriers such as electrons and holes confined in a single step-index waveguide laser (SSIWGL or single stepindex waveguide (SSIWG. Some optical expressions about the optical power and probability quantities for the active region and cladding layers of the SSIWG or SSIWGL have been investigated. Investigations have been undertaken in terms of these parameters and also individually the optical even and odd electric field waves with the lowest-modes were theoretically computed. Especially absorption coefficients and loss coefficients addition to some important quantities of the single step-index waveguide lasers for the even and odd electric field waves are evaluated.

  9. Phase detection electronics for CLIC

    CERN Document Server

    Andersson, A

    2011-01-01

    The Compact Linear Collider (CLIC) requires very tight RF phase synchronisation in order to preserve high luminosity. The electronics required for processing the signals delivered from the phase pick-ups present a significant challenge. This paper discusses the strategy adopted to achieve a sufficiently accurate measurement of the phase. Performance measurements performed in the lab of some of the sub-systems are also presented.

  10. Single-step generation of fluorophore-encapsulated gold nanoparticle core-shell materials

    International Nuclear Information System (INIS)

    Sardar, R; Shem, P M; Pecchia-Bekkum, C; Bjorge, N S; Shumaker-Parry, J S

    2010-01-01

    We report a simple route to produce fluorophore-encapsulated gold nanoparticles (AuNPs) in a single step under aqueous conditions using the fluorophore 1-pyrenemethylamine (PMA). Different amounts of PMA were used and the resulting core-shell gold nanoparticles were analyzed using UV-visible absorption spectroscopy, fluorescence spectroscopy, and transmission and scanning electron microscopy. Electron microscopy analysis shows nanoparticles consisting of a gold nanoparticle core which is encapsulated with a lower contrast shell. In the UV-visible spectra, we observed a significant red shift (37 nm) of the localized surface plasmon resonance (LSPR) absorption maximum (λ max ) compared to citrate-stabilized AuNPs of a similar size. We attribute the prominent LSPR wavelength shift for PMA-AuNP conjugates to the increase in the local dielectric environment near the gold nanoparticles due to the shell formation. This simple, aqueous-based synthesis is a new approach to the production of fluorophore-encapsulated AuNPs that could be applicable in biological sensing systems and photonic device fabrication.

  11. Single step thermal decomposition approach to prepare supported γ-Fe2O3 nanoparticles

    International Nuclear Information System (INIS)

    Sharma, Geetu; Jeevanandam, P.

    2012-01-01

    γ-Fe 2 O 3 nanoparticles supported on MgO (macro-crystalline and nanocrystalline) were prepared by an easy single step thermal decomposition method. Thermal decomposition of iron acetylacetonate in diphenyl ether, in the presence of the supports followed by calcination, leads to iron oxide nanoparticles supported on MgO. The X-ray diffraction results indicate the stability of γ-Fe 2 O 3 phase on MgO (macro-crystalline and nanocrystalline) up to 1150 °C. The scanning electron microscopy images show that the supported iron oxide nanoparticles are agglomerated while the energy dispersive X-ray analysis indicates the presence of iron, magnesium and oxygen in the samples. Transmission electron microscopy images indicate the presence of smaller γ-Fe 2 O 3 nanoparticles on nanocrystalline MgO. The magnetic properties of the supported magnetic nanoparticles at various calcination temperatures (350-1150 °C) were studied using a superconducting quantum interference device which indicates superparamagnetic behavior.

  12. The Point Zoro Symmetric Single-Step Procedure for Simultaneous Estimation of Polynomial Zeros

    Directory of Open Access Journals (Sweden)

    Mansor Monsi

    2012-01-01

    Full Text Available The point symmetric single step procedure PSS1 has R-order of convergence at least 3. This procedure is modified by adding another single-step, which is the third step in PSS1. This modified procedure is called the point zoro symmetric single-step PZSS1. It is proven that the R-order of convergence of PZSS1 is at least 4 which is higher than the R-order of convergence of PT1, PS1, and PSS1. Hence, computational time is reduced since this procedure is more efficient for bounding simple zeros simultaneously.

  13. Improving Genetic Evaluation of Litter Size Using a Single-step Model

    DEFF Research Database (Denmark)

    Guo, Xiangyu; Christensen, Ole Fredslund; Ostersen, Tage

    A recently developed single-step method allows genetic evaluation based on information from phenotypes, pedigree and markers simultaneously. This paper compared reliabilities of predicted breeding values obtained from single-step method and the traditional pedigree-based method for two litter size...... traits, total number of piglets born (TNB), and litter size at five days after birth (Ls 5) in Danish Landrace and Yorkshire pigs. The results showed that the single-step method combining phenotypic and genotypic information provided more accurate predictions than the pedigree-based method, not only...

  14. Detecting Kondo Entanglement by Electron Conductance

    Science.gov (United States)

    Yoo, Gwangsu; Lee, S.-S. B.; Sim, H.-S.

    2018-04-01

    Quantum entanglement between an impurity spin and electrons nearby is a key property of the single-channel Kondo effects. We show that the entanglement can be detected by measuring electron conductance through a double quantum dot in an orbital Kondo regime. We derive a relation between the entanglement and the conductance, when the SU(2) spin symmetry of the regime is weakly broken. The relation reflects the universal form of many-body states near the Kondo fixed point. Using it, the spatial distribution of the entanglement—hence, the Kondo cloud—can be detected, with breaking of the symmetry spatially nonuniformly by electrical means.

  15. Single step fabrication method of fullerene/TiO2 composite photocatalyst for hydrogen production

    International Nuclear Information System (INIS)

    Kum, Jong Min; Cho, Sung Oh

    2011-01-01

    Hydrogen is one of the most promising alternative energy sources. Fossil fuel, which is the most widely used energy source, has two defects. One is CO 2 emission causing global warming. The other is exhaustion. On the other hand, hydrogen emits no CO 2 and can be produced by splitting water which is renewable and easily obtainable source. However, about 95% of hydrogen is derived from fossil fuel. It limits the merits of hydrogen. Hydrogen from fossil fuel is not a renewable energy anymore. To maximize the merits of hydrogen, renewability and no CO 2 emission, unconventional hydrogen production methods without using fossil fuel are required. Photocatalytic water-splitting is one of the unconventional hydrogen production methods. Photocatalytic water-splitting that uses hole/electron pairs of semiconductor is expectable way to produce clean and renewable hydrogen from solar energy. TiO 2 is the semiconductor material which has been most widely used as photocatalyst. TiO 2 shows high photocatalytic reactivity and stability in water. However, its wide band gap only absorbs UV light which is only 5% of sun light. To enhance the visible light responsibility, composition with fullerene based materials has been investigated. 1-2 Methano-fullerene carboxylic acid (FCA) is one of the fullerene based materials. We tried to fabricate FCA/TiO 2 composite using UV assisted single step method. The method not only simplified the fabrication procedures, but enhanced hydrogen production rate

  16. A single-step synthesis of nitrogen-doped graphene sheets decorated with cobalt hydroxide nanoflakes for the determination of dopamine

    Directory of Open Access Journals (Sweden)

    Muhammad Mehmood Shahid

    2017-10-01

    Full Text Available Nitrogen-doped reduced graphene oxide (NrGO sheets decorated with Co(OH2 nanoflakes were prepared by a single-step hydrothermal process. The morphological and structural characterizations of as synthesized NrGO@Co(OH2 nanoflakes were performed by field emission scanning electron microscopy (FESEM, EDX-mapping and X-ray diffraction (XRD. NrGO@Co(OH2 nanoflakes modified glassy carbon electrode (GCE was used for electrochemical sensing of dopamine in neutral medium. The nanocomposite modified electrode showed enhanced electrochemical sensing ability for the detection of dopamine and the limit of detection (LoD was found to be 0.201 μM with a sensitivity value of 0.0286 ± 0.002 mA mM−1. Interference studies revealed that NrGO@Co(OH2─GCE endow excellent selectivity for DA detection even in the presence of higher concentration of common co-existing physiological interfering analytes. Additionally, proposed sensor demonstrated excellent performance in urine samples with promising reproducibility and stability. Keywords: Nitrogen doped graphene, Dopamine, Electrochemical sensor, Amperometric detection

  17. Ultrafast electron microscopy integrated with a direct electron detection camera

    Directory of Open Access Journals (Sweden)

    Young Min Lee

    2017-07-01

    Full Text Available In the past decade, we have witnessed the rapid growth of the field of ultrafast electron microscopy (UEM, which provides intuitive means to watch atomic and molecular motions of matter. Yet, because of the limited current of the pulsed electron beam resulting from space-charge effects, observations have been mainly made to periodic motions of the crystalline structure of hundreds of nanometers or higher by stroboscopic imaging at high repetition rates. Here, we develop an advanced UEM with robust capabilities for circumventing the present limitations by integrating a direct electron detection camera for the first time which allows for imaging at low repetition rates. This approach is expected to promote UEM to a more powerful platform to visualize molecular and collective motions and dissect fundamental physical, chemical, and materials phenomena in space and time.

  18. Ultrafast electron microscopy integrated with a direct electron detection camera.

    Science.gov (United States)

    Lee, Young Min; Kim, Young Jae; Kim, Ye-Jin; Kwon, Oh-Hoon

    2017-07-01

    In the past decade, we have witnessed the rapid growth of the field of ultrafast electron microscopy (UEM), which provides intuitive means to watch atomic and molecular motions of matter. Yet, because of the limited current of the pulsed electron beam resulting from space-charge effects, observations have been mainly made to periodic motions of the crystalline structure of hundreds of nanometers or higher by stroboscopic imaging at high repetition rates. Here, we develop an advanced UEM with robust capabilities for circumventing the present limitations by integrating a direct electron detection camera for the first time which allows for imaging at low repetition rates. This approach is expected to promote UEM to a more powerful platform to visualize molecular and collective motions and dissect fundamental physical, chemical, and materials phenomena in space and time.

  19. Comparison study on mechanical properties single step and three step artificial aging on duralium

    Science.gov (United States)

    Tsamroh, Dewi Izzatus; Puspitasari, Poppy; Andoko, Sasongko, M. Ilman N.; Yazirin, Cepi

    2017-09-01

    Duralium is kind of non-ferro alloy that used widely in industrial. That caused its properties such as mild, high ductility, and resistance from corrosion. This study aimed to know mechanical properties of duralium on single step and three step articial aging process. Mechanical properties that discussed in this study focused on toughness value, tensile strength, and microstructure of duralium. Toughness value of single step artificial aging was 0.082 joule/mm2, and toughness value of three step artificial aging was 0,0721 joule/mm2. Duralium tensile strength of single step artificial aging was 32.36 kgf/mm^2, and duralium tensile strength of three step artificial aging was 32,70 kgf/mm^2. Based on microstructure photo of duralium of single step artificial aging showed that precipitate (θ) was not spreading evenly indicated by black spot which increasing the toughness of material. While microstructure photo of duralium that treated by three step artificial aging showed that it had more precipitate (θ) spread evenly compared with duralium that treated by single step artificial aging.

  20. Single-step link of the superdeformed band in 143Eu

    International Nuclear Information System (INIS)

    Atac, A.; Bergstroem, M.H.; Nyberg, J.; Persson, J.; Herskind, B.; Joss, D.T.; Lipoglavsek, M.; Tucek, K.

    1996-01-01

    A discrete γ-ray ransition with an energy of 3360.6 keV deexciting the second lowest SD state in 143 Eu has been discovered. It carries 3.2 % of the full intensity of the band and feeds into a nearly spherical state which is above the I = 35/2 (+) , E x =4947 keV level. The exact placement of the single-step link is, however, not established due to the specially complicated level scheme in the region of interest. The energy of the single-step link agrees well with the previously determined two-step links. (orig.)

  1. Design of electron detection system for pulse electron irradiator

    International Nuclear Information System (INIS)

    Anjar Anggraini H; Agus Purwadi; Lely Susita RM; Bambang Siswanto; Agus Wijayanto

    2016-01-01

    Design of electron detection system for pulse electron irradiator has been conducted on the Plasma Cathode Electron Source by Rogowski coil technique. Rogowski coil has ability to capture the induced magnetic field of the electric current, subsequent induced magnetic field will provide voltage after passing integrator. This diagnostic used combination of copper wire, ferrite and RC integrator. The design depends on the pulse width and the value of plasma current that passes through the coil, thus the number of windings, coil area and integrator can be designed. For plasma spots current of IDPS expected to be 10 A and pulse width 10 μs the Rogowski coil using MnZn ferrite with inductance L = 0.275 mH and permeability μr = 200 H/m. For the current of plasma arc ADPS expected to be 100 A and pulse width 100 μs by using inductance L=1.9634 mH and permeability μr = 6256 H/m. Electron current in extraction system expected to be 30 A and pulse width 100 μs the Rogowski coil using inductance L=51.749 mH and permeability μr= 4987 H/m. Design integrator used is the type of RC integrator. (author)

  2. A new plastic scintillation resin for single-step separation, concentration and measurement of technetium-99.

    Science.gov (United States)

    Barrera, J; Tarancón, A; Bagán, H; García, J F

    2016-09-14

    Technetium is a synthetic element with no stable isotopes, produced as waste in nuclear power plants and in cyclotrons used for nuclear medicine. The element has high mobility, in the form of TcO4(-); its determination is therefore important for environmental protection. Technetium is found in low concentrations and therefore common methods for its analysis include long treatments in several steps and require large amounts of reagents for its purification and preconcentration. Plastic scintillation resins (PSresin) are novel materials used to separate, preconcentrate and measure radionuclides in a single step. The objective of this study is to prepare and characterise a PSresin for the preconcentration and measurement of (99)Tc. The study first evaluates the reproducibility of the production of PSresins between batches and over time; showing good reproducibility and storage stability. Next, we studied the effect of some common non-radioactive interferences, showing small influences on measurement, and radioactive interferences ((36)Cl and (238)U/(234)U). (36)Cl can be removed by a simple treatment with 0.5 M HCl and (238)U/(234)U can be removed from the column by cleaning with a mixture of 0.1 M HNO3 and 0.1 M HF. In the latter case, a slight change in the morphology of the PSresin caused an increase in detection efficiency. Finally, the PSresin was applied to the measurement of real spiked samples (sea water and urine) with deviations lower than 10% in all cases. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. A new plastic scintillation resin for single-step separation, concentration and measurement of technetium-99

    Energy Technology Data Exchange (ETDEWEB)

    Barrera, J. [Department of Analytical Chemistry, Universitat de Barcelona, Martí i Franqués, 1-11, E-08028, Barcelona (Spain); Tarancón, A., E-mail: alex.tarancon@ub.edu [Department of Analytical Chemistry, Universitat de Barcelona, Martí i Franqués, 1-11, E-08028, Barcelona (Spain); Bagán, H. [Department of Pure and Applied Biochemistry, Lund University, Getingevägen 60, hus II, 22100 SE, Lund (Sweden); García, J.F. [Department of Analytical Chemistry, Universitat de Barcelona, Martí i Franqués, 1-11, E-08028, Barcelona (Spain)

    2016-09-14

    Technetium is a synthetic element with no stable isotopes, produced as waste in nuclear power plants and in cyclotrons used for nuclear medicine. The element has high mobility, in the form of TcO{sub 4}{sup −}; its determination is therefore important for environmental protection. Technetium is found in low concentrations and therefore common methods for its analysis include long treatments in several steps and require large amounts of reagents for its purification and preconcentration. Plastic scintillation resins (PSresin) are novel materials used to separate, preconcentrate and measure radionuclides in a single step. The objective of this study is to prepare and characterise a PSresin for the preconcentration and measurement of {sup 99}Tc. The study first evaluates the reproducibility of the production of PSresins between batches and over time; showing good reproducibility and storage stability. Next, we studied the effect of some common non-radioactive interferences, showing small influences on measurement, and radioactive interferences ({sup 36}Cl and {sup 238}U/{sup 234}U). {sup 36}Cl can be removed by a simple treatment with 0.5 M HCl and {sup 238}U/{sup 234}U can be removed from the column by cleaning with a mixture of 0.1 M HNO{sub 3} and 0.1 M HF. In the latter case, a slight change in the morphology of the PSresin caused an increase in detection efficiency. Finally, the PSresin was applied to the measurement of real spiked samples (sea water and urine) with deviations lower than 10% in all cases. - Highlights: • A plastic scintillation resin for selective analysis of {sup 99}Tc has been developed. • The method is valid for analysis of {sup 99}Tc in seawater and urine samples. • Presence of Cl{sup −}, NO{sub 3}{sup −}, SO{sub 4}{sup 2−}, {sup 36}Cl, U and Th not affect retention of {sup 99}Tc.

  4. Novel structure formation at the bottom surface of porous anodic alumina fabricated by single step anodization process.

    Science.gov (United States)

    Ali, Ghafar; Ahmad, Maqsood; Akhter, Javed Iqbal; Maqbool, Muhammad; Cho, Sung Oh

    2010-08-01

    A simple approach for the growth of long-range highly ordered nanoporous anodic alumina film in H(2)SO(4) electrolyte through a single step anodization without any additional pre-anodizing procedure is reported. Free-standing porous anodic alumina film of 180 microm thickness with through hole morphology was obtained. A simple and single step process was used for the detachment of alumina from aluminum substrate. The effect of anodizing conditions, such as anodizing voltage and time on the pore diameter and pore ordering is discussed. The metal/oxide and oxide/electrolyte interfaces were examined by high resolution scanning transmission electron microscope. The arrangement of pores on metal/oxide interface was well ordered with smaller diameters than that of the oxide/electrolyte interface. The inter-pore distance was larger in metal/oxide interface as compared to the oxide/electrolyte interface. The size of the ordered domain was found to depend strongly upon anodizing voltage and time. (c) 2010 Elsevier Ltd. All rights reserved.

  5. Single-step colloidal quantum dot films for infrared solar harvesting

    KAUST Repository

    Kiani, Amirreza; Sutherland, Brandon R.; Kim, Younghoon; Ouellette, Olivier; Levina, Larissa; Walters, Grant; Dinh, Cao Thang; Liu, Mengxia; Voznyy, Oleksandr; Lan, Xinzheng; Labelle, Andre J.; Ip, Alexander H.; Proppe, Andrew; Ahmed, Ghada H.; Mohammed, Omar F.; Hoogland, Sjoerd; Sargent, Edward H.

    2016-01-01

    . To date, IR CQD solar cells have been made using a wasteful and complex sequential layer-by-layer process. Here, we demonstrate ∼1 eV bandgap solar-harvesting CQD films deposited in a single step. By engineering a fast-drying solvent mixture for metal

  6. Towards single step production of multi-layer inorganic hollow fibers

    NARCIS (Netherlands)

    de Jong, J.; Benes, Nieck Edwin; Koops, G.H.; Wessling, Matthias

    2004-01-01

    In this work we propose a generic synthesis route for the single step production of multi-layer inorganic hollow fibers, based on polymer wet spinning combined with a heat treatment. With this new method, membranes with a high surface area per unit volume ratio can be produced, while production time

  7. Nanopatterning of magnetic disks by single-step Ar+ Ion projection

    NARCIS (Netherlands)

    Dietzel, A.H.; Berger, R.; Loeschner, H.; Platzgummer, E.; Stengl, G.; Bruenger, W.H.; Letzkus, F.

    2003-01-01

    Large-area Ar+ projection has been used to generate planar magnetic nanostructures on a 1¿-format hard disk in a single step (see Figure). The recording pattern was transferred to a Co/Pt multilayer without resist processes or any other contact to the delicate media surface. It is conceivable that

  8. Accuracy of Single-Step versus 2-Step Double-Mix Impression Technique

    DEFF Research Database (Denmark)

    Franco, Eduardo Batista; da Cunha, Leonardo Fernandes; Herrera, Francyle Simões

    2011-01-01

    Objective. To investigate the accuracy of dies obtained from single-step and 2-step double-mix impressions. Material and Methods. Impressions (n = 10) of a stainless steel die simulating a complete crown preparation were performed using a polyether (Impregum Soft Heavy and Light body) and a vinyl...

  9. Rapid, single-step most-probable-number method for enumerating fecal coliforms in effluents from sewage treatment plants

    Science.gov (United States)

    Munoz, E. F.; Silverman, M. P.

    1979-01-01

    A single-step most-probable-number method for determining the number of fecal coliform bacteria present in sewage treatment plant effluents is discussed. A single growth medium based on that of Reasoner et al. (1976) and consisting of 5.0 gr. proteose peptone, 3.0 gr. yeast extract, 10.0 gr. lactose, 7.5 gr. NaCl, 0.2 gr. sodium lauryl sulfate, and 0.1 gr. sodium desoxycholate per liter is used. The pH is adjusted to 6.5, and samples are incubated at 44.5 deg C. Bacterial growth is detected either by measuring the increase with time in the electrical impedance ratio between the innoculated sample vial and an uninnoculated reference vial or by visual examination for turbidity. Results obtained by the single-step method for chlorinated and unchlorinated effluent samples are in excellent agreement with those obtained by the standard method. It is suggested that in automated treatment plants impedance ratio data could be automatically matched by computer programs with the appropriate dilution factors and most probable number tables already in the computer memory, with the corresponding result displayed as fecal coliforms per 100 ml of effluent.

  10. Fluoroscopic-guided primary single-step percutaneous gastrostomy. Initial results using the Freka {sup registered} GastroTube; Primaere einzeitige durchleuchtungsgesteuerte perkutane Gastrostomie (PG). Erste Ergebnisse mit dem Freka {sup registered} GastroTube

    Energy Technology Data Exchange (ETDEWEB)

    Hahne, J.D.; Schoennagel, B.P.; Arndt, C.; Bannas, P.; Koops, A.; Adam, G.; Habermann, C.R. [Universitaetsklinikum Hamburg-Eppendorf (Germany). Zentrum fuer Radiologie; Herrmann, J. [Universitaetsklinikum Hamburg-Eppendorf (Germany). Zentrum fuer Radiologie; Universitaetsklinikum Hamburg-Eppendorf (Germany). Abt. Paediatrische Radiologie

    2011-07-15

    Purpose: To determine the practicability and outcome of fluoroscopic-guided primary one-step treatment of percutaneous gastrostomy (PG) with the system Freka {sup registered} Gastro Tube (Fresenius Kabi, Germany). Materials and Methods: In 39 patients (mean age 62.7 {+-} 12.0 years), primary PG was performed based on clinical indication from August 2009 to April 2010. The intervention was performed by an experienced radiologist under aseptic conditions by direct puncture with Freka {sup registered} Gastro Tube under fluoroscopic guidance. The clinical data and outcome as well as any complications originated from the electronic archive of the University Medical Center Hamburg-Eppendorf. Results: The intervention was technically successful in all 39 patients. Within the mean follow-up time of 155.3 {+-} 73.6 days, 29 patients (74.4 %) did not experience complications. 10 patients (25.6 %) had to be revised. Complications manifested after a mean of 135.6 {+-} 61.2 days and mainly corresponded to accidental dislocation (50 %). One patient had to be surgically revised under suspicion of a malpositioned tube and suspected intestinal perforation. Clinically relevant wound infections were not detected. The total costs per patient were 553.17 Euro for our single-step treatment (OPS 5 - 431.x) vs. 963.69 Euro (OPS 5 - 431.x and OPS 8 - 123.0) for the recommended two-step treatment. Conclusion: Fluoroscopic-guided primary single-step treatment with Freka {sup registered} Gastro Tube system is feasible and not associated with an increased complication rate when compared to published literature applying a two-step treatment approach. Material costs as well as human and time resources could be significantly reduced using the single-step treatment. (orig.)

  11. Genomic prediction in a nuclear population of layers using single-step models.

    Science.gov (United States)

    Yan, Yiyuan; Wu, Guiqin; Liu, Aiqiao; Sun, Congjiao; Han, Wenpeng; Li, Guangqi; Yang, Ning

    2018-02-01

    Single-step genomic prediction method has been proposed to improve the accuracy of genomic prediction by incorporating information of both genotyped and ungenotyped animals. The objective of this study is to compare the prediction performance of single-step model with a 2-step models and the pedigree-based models in a nuclear population of layers. A total of 1,344 chickens across 4 generations were genotyped by a 600 K SNP chip. Four traits were analyzed, i.e., body weight at 28 wk (BW28), egg weight at 28 wk (EW28), laying rate at 38 wk (LR38), and Haugh unit at 36 wk (HU36). In predicting offsprings, individuals from generation 1 to 3 were used as training data and females from generation 4 were used as validation set. The accuracies of predicted breeding values by pedigree BLUP (PBLUP), genomic BLUP (GBLUP), SSGBLUP and single-step blending (SSBlending) were compared for both genotyped and ungenotyped individuals. For genotyped females, GBLUP performed no better than PBLUP because of the small size of training data, while the 2 single-step models predicted more accurately than the PBLUP model. The average predictive ability of SSGBLUP and SSBlending were 16.0% and 10.8% higher than the PBLUP model across traits, respectively. Furthermore, the predictive abilities for ungenotyped individuals were also enhanced. The average improvements of prediction abilities were 5.9% and 1.5% for SSGBLUP and SSBlending model, respectively. It was concluded that single-step models, especially the SSGBLUP model, can yield more accurate prediction of genetic merits and are preferable for practical implementation of genomic selection in layers. © 2017 Poultry Science Association Inc.

  12. A new plastic scintillation resin for single-step separation, concentration and measurement of technetium-99

    International Nuclear Information System (INIS)

    Barrera, J.; Tarancón, A.; Bagán, H.; García, J.F.

    2016-01-01

    Technetium is a synthetic element with no stable isotopes, produced as waste in nuclear power plants and in cyclotrons used for nuclear medicine. The element has high mobility, in the form of TcO_4"−; its determination is therefore important for environmental protection. Technetium is found in low concentrations and therefore common methods for its analysis include long treatments in several steps and require large amounts of reagents for its purification and preconcentration. Plastic scintillation resins (PSresin) are novel materials used to separate, preconcentrate and measure radionuclides in a single step. The objective of this study is to prepare and characterise a PSresin for the preconcentration and measurement of "9"9Tc. The study first evaluates the reproducibility of the production of PSresins between batches and over time; showing good reproducibility and storage stability. Next, we studied the effect of some common non-radioactive interferences, showing small influences on measurement, and radioactive interferences ("3"6Cl and "2"3"8U/"2"3"4U). "3"6Cl can be removed by a simple treatment with 0.5 M HCl and "2"3"8U/"2"3"4U can be removed from the column by cleaning with a mixture of 0.1 M HNO_3 and 0.1 M HF. In the latter case, a slight change in the morphology of the PSresin caused an increase in detection efficiency. Finally, the PSresin was applied to the measurement of real spiked samples (sea water and urine) with deviations lower than 10% in all cases. - Highlights: • A plastic scintillation resin for selective analysis of "9"9Tc has been developed. • The method is valid for analysis of "9"9Tc in seawater and urine samples. • Presence of Cl"−, NO_3"−, SO_4"2"−, "3"6Cl, U and Th not affect retention of "9"9Tc.

  13. Single-step linking transition from superdeformed to spherical states in {sup 143}Eu

    Energy Technology Data Exchange (ETDEWEB)

    Atac, A.; Axelsson, A.; Persson, J. [Uppsala Univ. (Sweden)] [and others

    1996-12-31

    A discrete {gamma}-ray transition which connects the second lowest SD state with a normally deformed one in {sup 143}Eu has been discovered. It has an energy of 3360.6 keV and carries 3.2 % of the full intensity of the SD band. It feeds into a nearly spherical state which is above the I = 35/2{sup +}, E=4947 keV level. The exact placement of the single-step link could, however, not be established due to the especially complicated level scheme in the region of interest. The angular correlation study favours a stretched dipole character for the 3360.6 keV transition. The single-step link agrees well with the previously determined two-step links, both with respect to energy and spin.

  14. A single-step method for rapid extraction of total lipids from green microalgae.

    Directory of Open Access Journals (Sweden)

    Martin Axelsson

    Full Text Available Microalgae produce a wide range of lipid compounds of potential commercial interest. Total lipid extraction performed by conventional extraction methods, relying on the chloroform-methanol solvent system are too laborious and time consuming for screening large numbers of samples. In this study, three previous extraction methods devised by Folch et al. (1957, Bligh and Dyer (1959 and Selstam and Öquist (1985 were compared and a faster single-step procedure was developed for extraction of total lipids from green microalgae. In the single-step procedure, 8 ml of a 2∶1 chloroform-methanol (v/v mixture was added to fresh or frozen microalgal paste or pulverized dry algal biomass contained in a glass centrifuge tube. The biomass was manually suspended by vigorously shaking the tube for a few seconds and 2 ml of a 0.73% NaCl water solution was added. Phase separation was facilitated by 2 min of centrifugation at 350 g and the lower phase was recovered for analysis. An uncharacterized microalgal polyculture and the green microalgae Scenedesmus dimorphus, Selenastrum minutum, and Chlorella protothecoides were subjected to the different extraction methods and various techniques of biomass homogenization. The less labour intensive single-step procedure presented here allowed simultaneous recovery of total lipid extracts from multiple samples of green microalgae with quantitative yields and fatty acid profiles comparable to those of the previous methods. While the single-step procedure is highly correlated in lipid extractability (r² = 0.985 to the previous method of Folch et al. (1957, it allowed at least five times higher sample throughput.

  15. Towards Single-Step Biofabrication of Organs on a Chip via 3D Printing.

    Science.gov (United States)

    Knowlton, Stephanie; Yenilmez, Bekir; Tasoglu, Savas

    2016-09-01

    Organ-on-a-chip engineering employs microfabrication of living tissues within microscale fluid channels to create constructs that closely mimic human organs. With the advent of 3D printing, we predict that single-step fabrication of these devices will enable rapid design and cost-effective iterations in the development stage, facilitating rapid innovation in this field. Copyright © 2016 Elsevier Ltd. All rights reserved.

  16. Single-Step Fabrication of High-Density Microdroplet Arrays of Low-Surface-Tension Liquids.

    Science.gov (United States)

    Feng, Wenqian; Li, Linxian; Du, Xin; Welle, Alexander; Levkin, Pavel A

    2016-04-01

    A facile approach for surface patterning that enables single-step fabrication of high-density arrays of low-surface-tension organic-liquid microdroplets is described. This approach enables miniaturized and parallel high-throughput screenings in organic solvents, formation of homogeneous arrays of hydrophobic nanoparticles, polymer micropads of specific shapes, and polymer microlens arrays. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. Diffusion welding. [heat treatment of nickel alloys following single step vacuum welding process

    Science.gov (United States)

    Holko, K. H. (Inventor)

    1974-01-01

    Dispersion-strengthened nickel alloys are sanded on one side and chemically polished. This is followed by a single-step welding process wherein the polished surfaces are forced into intimate contact at 1,400 F for one hour in a vacuum. Diffusion, recrystallization, and grain growth across the original weld interface are obtained during postheating at 2,150 F for two hours in hydrogen.

  18. Computing single step operators of logic programming in radial basis function neural networks

    Energy Technology Data Exchange (ETDEWEB)

    Hamadneh, Nawaf; Sathasivam, Saratha; Choon, Ong Hong [School of Mathematical Sciences, Universiti Sains Malaysia, 11800 USM, Penang (Malaysia)

    2014-07-10

    Logic programming is the process that leads from an original formulation of a computing problem to executable programs. A normal logic program consists of a finite set of clauses. A valuation I of logic programming is a mapping from ground atoms to false or true. The single step operator of any logic programming is defined as a function (T{sub p}:I→I). Logic programming is well-suited to building the artificial intelligence systems. In this study, we established a new technique to compute the single step operators of logic programming in the radial basis function neural networks. To do that, we proposed a new technique to generate the training data sets of single step operators. The training data sets are used to build the neural networks. We used the recurrent radial basis function neural networks to get to the steady state (the fixed point of the operators). To improve the performance of the neural networks, we used the particle swarm optimization algorithm to train the networks.

  19. Computing single step operators of logic programming in radial basis function neural networks

    Science.gov (United States)

    Hamadneh, Nawaf; Sathasivam, Saratha; Choon, Ong Hong

    2014-07-01

    Logic programming is the process that leads from an original formulation of a computing problem to executable programs. A normal logic program consists of a finite set of clauses. A valuation I of logic programming is a mapping from ground atoms to false or true. The single step operator of any logic programming is defined as a function (Tp:I→I). Logic programming is well-suited to building the artificial intelligence systems. In this study, we established a new technique to compute the single step operators of logic programming in the radial basis function neural networks. To do that, we proposed a new technique to generate the training data sets of single step operators. The training data sets are used to build the neural networks. We used the recurrent radial basis function neural networks to get to the steady state (the fixed point of the operators). To improve the performance of the neural networks, we used the particle swarm optimization algorithm to train the networks.

  20. Composition of single-step media used for human embryo culture.

    Science.gov (United States)

    Morbeck, Dean E; Baumann, Nikola A; Oglesbee, Devin

    2017-04-01

    To determine compositions of commercial single-step culture media and test with a murine model whether differences in composition are biologically relevant. Experimental laboratory study. University-based laboratory. Inbred female mice were superovulated and mated with outbred male mice. Amino acid, organic acid, and ions content were determined for single-step culture media: CSC, Global, G-TL, and 1-Step. To determine whether differences in composition of these media are biologically relevant, mouse one-cell embryos were cultured for 96 hours in each culture media at 5% and 20% oxygen in a time-lapse incubator. Compositions of four culture media were analyzed for concentrations of 30 amino acids, organic acids, and ions. Blastocysts at 96 hours of culture and cell cycle timings were calculated, and experiments were repeated in triplicate. Of the more than 30 analytes, concentrations of glucose, lactate, pyruvate, amino acids, phosphate, calcium, and magnesium varied in concentrations. Mouse embryos were differentially affected by oxygen in G-TL and 1-Step. Four single-step culture media have compositions that vary notably in pyruvate, lactate, and amino acids. Blastocyst development was affected by culture media and its interaction with oxygen concentration. Copyright © 2017 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.

  1. Computing single step operators of logic programming in radial basis function neural networks

    International Nuclear Information System (INIS)

    Hamadneh, Nawaf; Sathasivam, Saratha; Choon, Ong Hong

    2014-01-01

    Logic programming is the process that leads from an original formulation of a computing problem to executable programs. A normal logic program consists of a finite set of clauses. A valuation I of logic programming is a mapping from ground atoms to false or true. The single step operator of any logic programming is defined as a function (T p :I→I). Logic programming is well-suited to building the artificial intelligence systems. In this study, we established a new technique to compute the single step operators of logic programming in the radial basis function neural networks. To do that, we proposed a new technique to generate the training data sets of single step operators. The training data sets are used to build the neural networks. We used the recurrent radial basis function neural networks to get to the steady state (the fixed point of the operators). To improve the performance of the neural networks, we used the particle swarm optimization algorithm to train the networks

  2. Compatibility of pedigree-based and marker-based relationship matrices for single-step genetic evaluation

    DEFF Research Database (Denmark)

    Christensen, Ole Fredslund

    2012-01-01

    Single-step methods for genomic prediction have recently become popular because they are conceptually simple and in practice such a method can completely replace a pedigree-based method for routine genetic evaluation. An issue with single-step methods is compatibility between the marker-based rel...

  3. Fast Synthesis of High Quality Biodiesel from ‘Waste Fish Oil’ by Single Step Transesterification

    Directory of Open Access Journals (Sweden)

    Yogesh C. Sharma

    2014-09-01

    Full Text Available A large volume of fish wastes is produced on a daily basis in the Indian sub-continent. This abundant waste source could serve as an economic feedstock for bioenergy generation. In the present study, oil extracted from discarded fish parts was used for high quality biodiesel production. More specifically, a single step transesterification of ‘waste fishoil’ with methanol using sodium methoxide (CH3ONa as homogeneous catalyst under moderate operational conditions resulted in highly pure biodiesel of > 98% of fatty acid methyl ester (FAME content. Characterization was performed by Fourier Transform-Nuclear Magnetic Resonance (FT-NMR.

  4. Binary Factorization in Hopfield-Like Neural Networks: Single-Step Approximation and Computer Simulations

    Czech Academy of Sciences Publication Activity Database

    Frolov, A. A.; Sirota, A.M.; Húsek, Dušan; Muraviev, I. P.

    2004-01-01

    Roč. 14, č. 2 (2004), s. 139-152 ISSN 1210-0552 R&D Projects: GA ČR GA201/01/1192 Grant - others:BARRANDE(EU) 99010-2/99053; Intellectual computer Systems(EU) Grant 2.45 Institutional research plan: CEZ:AV0Z1030915 Keywords : nonlinear binary factor analysis * feature extraction * recurrent neural network * Single-Step approximation * neurodynamics simulation * attraction basins * Hebbian learning * unsupervised learning * neuroscience * brain function modeling Subject RIV: BA - General Mathematics

  5. Electric field dependent paramagnetic defect creation in single step implanted Simox films

    International Nuclear Information System (INIS)

    Leray, J.L.; Margail, J.

    1991-01-01

    X irradiation induced oxygen-vacancy defect creation has been studied in SIMOX produced by single step implantation and annealing. It is shown that SIMOX is substantially more radiation sensitive (for these defects) than thermal or bulk oxide. Irradiation in the presence of an electric field 0.5 -1 MV cm -1 is found to enhance the rate of defect creation by ≥ 2 times. Further enhanced defect creation is observed in SIMOX samples whose substrate has been chemically thinned prior to irradiation. This enhancement is attributed to modification of the network induced by hydrogen introduced during the thinning process

  6. Single electron based binary multipliers with overflow detection ...

    African Journals Online (AJOL)

    electron based device. Multipliers with overflow detection based on serial and parallel prefix computation algorithm are elaborately discussed analytically and designed. The overflow detection circuits works in parallel with a simplified multiplier to ...

  7. Bridge flap technique as a single-step solution to mucogingival problems: A case series

    Directory of Open Access Journals (Sweden)

    Vivek Gupta

    2011-01-01

    Full Text Available Shallow vestibule, gingival recession, inadequate width of attached gingiva (AG and aberrant frenum pull are an array of mucogingival problems for which several independent and effective surgical solutions are reported in the literature. This case series reports the effectiveness of the bridge flap technique as a single-step surgical entity for increasing the depth of the vestibule, root coverage, increasing the width of the AG and solving the problem of abnormal frenum pull. Eight patients with 18 teeth altogether having Millers class I, II or III recession along with problems of shallow vestibule, inadequate width of AG and with or without frenum pull underwent this surgical procedure and were followed-up till 9 months post-operatively. The mean root coverage obtained was 55% and the mean average gain in width of the AG was 3.5 mm. The mean percentage gain in clinical attachment level was 41%. The bridge flap technique can be an effective single-step solution for the aforementioned mucogingival problems if present simultaneously in any case, and offers considerable advantages over other mucogingival surgical techniques in terms of simplicity, limited chair-time for the patient and the operator, single surgical intervention for manifold mucogingival problems and low morbidity because of the absence of palatal donor tissue.

  8. Quickest single-step one pot mechanosynthesis and characterization of ZnTe quantum dots

    Energy Technology Data Exchange (ETDEWEB)

    Patra, S. [Dept of Physics, University of Burdwan, Golapbag, Burdwan, West Bengal 713104 (India); Pradhan, S.K., E-mail: skp_bu@yahoo.com [Dept of Physics, University of Burdwan, Golapbag, Burdwan, West Bengal 713104 (India)

    2011-05-05

    Research highlights: > First time quickest mechanosynthesis of ZnTe QDs starting from Zn and Te powders. > Cubic ZnTe are formed in a single pot at RT in a single step within 1 h of milling. > The existence of stacking faults and twin faults are evident from HRTEM images. > Distinct blue shift has been observed in UV-vis absorption spectra. > First time report that ZnTe QDs with faults can also show the quantum size effect. - Abstract: ZnTe quantum dots (QDs) are synthesized at room temperature in a single step by mechanical alloying the stoichiometric equimolar mixture (1:1 mol) of Zn and Te powders under Ar within 1 h of milling. Both XRD and HRTEM characterizations reveal that these QDs having size {approx}5 nm contain stacking faults of different kinds. A distinct blue-shift in absorption spectra with decreasing particle size of QDs confirms the quantum size confinement effect (QSCE). It is observed for first time that the QDs with considerable amount of faults can also show the QSCE. Optical band gaps of these QDs increase with increasing milling time and their band gaps can be fine-tuned easily by varying milling time of QDs.

  9. Single-step fabrication of electrodes with controlled nanostructured surface roughness using optically-induced electrodeposition

    Science.gov (United States)

    Liu, N.; Li, M.; Liu, L.; Yang, Y.; Mai, J.; Pu, H.; Sun, Y.; Li, W. J.

    2018-02-01

    The customized fabrication of microelectrodes from gold nanoparticles (AuNPs) has attracted much attention due to their numerous applications in chemistry and biomedical engineering, such as for surface-enhanced Raman spectroscopy (SERS) and as catalyst sites for electrochemistry. Herein, we present a novel optically-induced electrodeposition (OED) method for rapidly fabricating gold electrodes which are also surface-modified with nanoparticles in one single step. The electrodeposition mechanism, with respect to the applied AC voltage signal and the elapsed deposition time, on the resulting morphology and particle sizes was investigated. The results from SEM and AFM analysis demonstrated that 80-200 nm gold particles can be formed on the surface of the gold electrodes. Simultaneously, both the size of the nanoparticles and the roughness of the fabricated electrodes can be regulated by the deposition time. Compared to state-of-the-art methods for fabricating microelectrodes with AuNPs, such as nano-seed-mediated growth and conventional electrodeposition, this OED technique has several advantages including: (1) electrode fabrication and surface modification using nanoparticles are completed in a single step, eliminating the need for prefabricating micro electrodes; (2) the patterning of electrodes is defined using a digitally-customized, projected optical image rather than using fixed physical masks; and (3) both the fabrication and surface modification processes are rapid, and the entire fabrication process only requires less than 6 s.

  10. Single-step in-situ synthesis and optical properties of ZnSe nanostructured dielectric nanocomposites

    Energy Technology Data Exchange (ETDEWEB)

    Dey, Chirantan; Rahaman Molla, Atiar; Tarafder, Anal; Karmakar, Basudeb, E-mail: basudebk@cgcri.res.in [CSIR-Central Glass and Ceramic Research Institute, Glass Science and Technology Section, Glass Division, 196, Raja S. C. Mullick Road, 700032 Kolkata (India); Kr Mishra, Manish; De, Goutam [CSIR-Central Glass and Ceramic Research Institute, Nano-Structured Materials Division, 196, Raja S. C. Mullick Road, 700032 Kolkata (India); Goswami, Madhumita; Kothiyal, G. P. [Glass and Advanced Ceramics Division, Bhaba Atomic Research Centre, Trombay, 400085 Mumbai (India)

    2014-04-07

    This work provides the evidence of visible red photoluminescent light emission from ZnSe nanocrystals (NCs) grown within a dielectric (borosilicate glass) matrix synthesized by a single step in-situ technique for the first time and the NC sizes were controlled by varying only the concentration of ZnSe in glass matrix. The ZnSe NCs were investigated by UV-Vis optical absorption spectroscopy, Raman spectroscopy, and transmission electron microscopy (TEM). The sizes of the ZnSe NCs estimated from the TEM images are found to alter in the range of 2–53 nm. Their smaller sizes of the NCs were also calculated by using the optical absorption spectra and the effective mass approximation model. The band gap enlargements both for carrier and exciton confinements were evaluated and found to be changed in the range of 0–1.0 eV. The Raman spectroscopic studies showed blue shifted Raman peaks of ZnSe at 295 and 315 cm{sup −1} indicating phonon confinement effect as well as compressive stress effect on the surface atoms of the NCs. Red photoluminescence in ZnSe-glass nanocomposite reveals a broad multiple-peak structure due to overlapping of emission from NC size related electron-hole recombination (∼707 nm) and emissions from defects to traps, which were formed due to Se and Zn vacancies signifying potential application in photonics.

  11. Magnetic Beads-Based Sensor with Tailored Sensitivity for Rapid and Single-Step Amperometric Determination of miRNAs

    Directory of Open Access Journals (Sweden)

    Eva Vargas

    2017-11-01

    Full Text Available This work describes a sensitive amperometric magneto-biosensor for single-step and rapid determination of microRNAs (miRNAs. The developed strategy involves the use of direct hybridization of the target miRNA (miRNA-21 with a specific biotinylated DNA probe immobilized on streptavidin-modified magnetic beads (MBs, and labeling of the resulting heteroduplexes with a specific DNA–RNA antibody and the bacterial protein A (ProtA conjugated with an horseradish peroxidase (HRP homopolymer (Poly-HRP40 as an enzymatic label for signal amplification. Amperometric detection is performed upon magnetic capture of the modified MBs onto the working electrode surface of disposable screen-printed carbon electrodes (SPCEs using the H2O2/hydroquinone (HQ system. The magnitude of the cathodic signal obtained at −0.20 V (vs. the Ag pseudo-reference electrode demonstrated linear dependence with the concentration of the synthetic target miRNA over the 1.0 to 100 pM range. The method provided a detection limit (LOD of 10 attomoles (in a 25 μL sample without any target miRNA amplification in just 30 min (once the DNA capture probe-MBs were prepared. This approach shows improved sensitivity compared with that of biosensors constructed with the same anti-DNA–RNA Ab as capture instead of a detector antibody and further labeling with a Strep-HRP conjugate instead of the Poly-HRP40 homopolymer. The developed strategy involves a single step working protocol, as well as the possibility to tailor the sensitivity by enlarging the length of the DNA/miRNA heteroduplexes using additional probes and/or performing the labelling with ProtA conjugated with homopolymers prepared with different numbers of HRP molecules. The practical usefulness was demonstrated by determination of the endogenous levels of the mature target miRNA in 250 ng raw total RNA (RNAt extracted from human mammary epithelial normal (MCF-10A and cancer (MCF-7 cells and tumor tissues.

  12. Single step synthesis and organization of gold colloids assisted by copolymer templates

    International Nuclear Information System (INIS)

    Sarrazin, Aurélien; Gontier, Arthur; Plaud, Alexandre; Béal, Jérémie; Yockell-Lelièvre, Hélène; Bijeon, Jean-Louis; Plain, Jérôme; Adam, Pierre-Michel; Maurer, Thomas

    2014-01-01

    We report here an original single-step process for the synthesis and self-organization of gold colloids by simply incorporating gold salts into a solution prepared using polystyrene (PS)-polymethylmethacrylate copolymer and thiolated PS with propylene glycol methyl ether acetate as a solvent. The spin-coating and annealing of this solution then allows the formation of PS domains. Depending on the polymer concentration of the as-prepared solution, there can be either one or several gold nanoparticles (Au NPs) per PS domain. For high concentrations of Au NPs in PS domains, the coupling between plasmonic NPs leads to the observation of a second peak in the optical extinction spectrum. Such a collective effect could be relevant for the development of optical strain sensors in the near future. (papers)

  13. Single step synthesis and organization of gold colloids assisted by copolymer templates

    Science.gov (United States)

    Sarrazin, Aurélien; Gontier, Arthur; Plaud, Alexandre; Béal, Jérémie; Yockell-Lelièvre, Hélène; Bijeon, Jean-Louis; Plain, Jérôme; Adam, Pierre-Michel; Maurer, Thomas

    2014-06-01

    We report here an original single-step process for the synthesis and self-organization of gold colloids by simply incorporating gold salts into a solution prepared using polystyrene (PS)-polymethylmethacrylate copolymer and thiolated PS with propylene glycol methyl ether acetate as a solvent. The spin-coating and annealing of this solution then allows the formation of PS domains. Depending on the polymer concentration of the as-prepared solution, there can be either one or several gold nanoparticles (Au NPs) per PS domain. For high concentrations of Au NPs in PS domains, the coupling between plasmonic NPs leads to the observation of a second peak in the optical extinction spectrum. Such a collective effect could be relevant for the development of optical strain sensors in the near future.

  14. Single step vacuum-free and hydrogen-free synthesis of graphene

    Directory of Open Access Journals (Sweden)

    Christian Orellana

    2017-08-01

    Full Text Available We report a modified method to grow graphene in a single-step process. It is based on chemical vapor deposition and considers the use of methane under extremely adverse synthesis conditions, namely in an open chamber without requiring the addition of gaseous hydrogen in any of the synthesis stages. The synthesis occurs between two parallel Cu plates, heated up via electromagnetic induction. The inductive heating yields a strong thermal gradient between the catalytic substrates and the surrounding environment, promoting the enrichment of hydrogen generated as fragments of the methane molecules within the volume confined by the Cu foils. This induced density gradient is due to thermo-diffusion, also known as the Soret effect. Hydrogen and other low mass molecular fractions produced during the process inhibit oxidative effects and simultaneously reduce the native oxide on the Cu surface. As a result, high quality graphene is obtained on the inner surfaces of the Cu sheets as confirmed by Raman spectroscopy.

  15. Single-Step Generation of Conditional Knockout Mouse Embryonic Stem Cells

    Directory of Open Access Journals (Sweden)

    Matyas Flemr

    2015-07-01

    Full Text Available Induction of double-strand DNA breaks (DSBs by engineered nucleases, such as CRISPR/Cas9 or transcription activator-like effector nucleases (TALENs, stimulates knockin of exogenous DNA fragments via homologous recombination (HR. However, the knockin efficiencies reported so far have not allowed more complex in vitro genome modifications such as, for instance, simultaneous integration of a DNA fragment at two distinct genomic sites. We developed a reporter system to enrich for cells with engineered nuclease-assisted HR events. Using this system in mouse embryonic stem cells (mESCs, we achieve single-step biallelic and seamless integration of two loxP sites for Cre recombinase-mediated inducible gene knockout, as well as biallelic endogenous gene tagging with high efficiency. Our approach reduces the time and resources required for conditional knockout mESC generation dramatically.

  16. Analytic observations for the d=1+ 1 bridge site (or single-step) deposition model

    International Nuclear Information System (INIS)

    Evans, J.W.; Kang, H.C.

    1991-01-01

    Some exact results for a reversible version of the d=1+1 bridge site (or single-step) deposition model are presented. Exact steady-state properties are determined directly for finite systems with various mean slopes. These show explicitly how the asymptotic growth velocity and fluctuations are quenched as the slope approaches its maximum allowed value. Next, exact hierarchial equations for the dynamics are presented. For the special case of ''equilibrium growth,'' these are analyzed exactly at the pair-correlation level directly for an infinite system. This provided further insight into asymptotic scaling behavior. Finally, the above hierarchy is compared with one generated from a discrete form of the Kardar--Parisi--Zhang equations. Some differences are described

  17. Single-step controlled-NOT logic from any exchange interaction

    Science.gov (United States)

    Galiautdinov, Andrei

    2007-11-01

    A self-contained approach to studying the unitary evolution of coupled qubits is introduced, capable of addressing a variety of physical systems described by exchange Hamiltonians containing Rabi terms. The method automatically determines both the Weyl chamber steering trajectory and the accompanying local rotations. Particular attention is paid to the case of anisotropic exchange with tracking controls, which is solved analytically. It is shown that, if computational subspace is well isolated, any exchange interaction can always generate high fidelity, single-step controlled-NOT (CNOT) logic, provided that both qubits can be individually manipulated. The results are then applied to superconducting qubit architectures, for which several CNOT gate implementations are identified. The paper concludes with consideration of two CNOT gate designs having high efficiency and operating with no significant leakage to higher-lying noncomputational states.

  18. Separation of Be and Al for AMS using single-step column chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Binnie, Steven A., E-mail: sbinnie@uni-koeln.de [Institute for Geology und Mineralogy, University of Cologne, 4-6 Greinstrasse, Cologne D-50939 (Germany); Dunai, Tibor J.; Voronina, Elena; Goral, Tomasz [Institute for Geology und Mineralogy, University of Cologne, 4-6 Greinstrasse, Cologne D-50939 (Germany); Heinze, Stefan; Dewald, Alfred [University of Cologne, Institut für Kernphysik, Zülpicher Str. 77, Cologne D-50937 (Germany)

    2015-10-15

    With the aim of simplifying AMS target preparation procedures for TCN measurements we tested a new extraction chromatography approach which couples an anion exchange resin (WBEC) to a chelating resin (Beryllium resin) to separate Be and Al from dissolved quartz samples. Results show that WBEC–Beryllium resin stacks can be used to provide high purity Be and Al separations using a combination of hydrochloric/oxalic and nitric acid elutions. {sup 10}Be and {sup 26}Al concentrations from quartz samples prepared using more standard procedures are compared with results from replicate samples prepared using the coupled WBEC–Beryllium resin approach and show good agreement. The new column procedure is performed in a single step, reducing sample preparation times relative to more traditional methods of TCN target production.

  19. Separation of Be and Al for AMS using single-step column chromatography

    Science.gov (United States)

    Binnie, Steven A.; Dunai, Tibor J.; Voronina, Elena; Goral, Tomasz; Heinze, Stefan; Dewald, Alfred

    2015-10-01

    With the aim of simplifying AMS target preparation procedures for TCN measurements we tested a new extraction chromatography approach which couples an anion exchange resin (WBEC) to a chelating resin (Beryllium resin) to separate Be and Al from dissolved quartz samples. Results show that WBEC-Beryllium resin stacks can be used to provide high purity Be and Al separations using a combination of hydrochloric/oxalic and nitric acid elutions. 10Be and 26Al concentrations from quartz samples prepared using more standard procedures are compared with results from replicate samples prepared using the coupled WBEC-Beryllium resin approach and show good agreement. The new column procedure is performed in a single step, reducing sample preparation times relative to more traditional methods of TCN target production.

  20. Multipartite electronic entanglement purification with charge detection

    Energy Technology Data Exchange (ETDEWEB)

    Sheng Yubo [Department of Physics, Tsinghua University, Beijing 100084 (China); Deng, Fu-Guo [Department of Physics, Beijing Normal University, Beijing 100875 (China); Long Guilu, E-mail: gllong@tsinghua.edu.c [Department of Physics, Tsinghua University, Beijing 100084 (China); Key Laboratory for Atomic and Molecular NanoSciences, Tsinghua University, Beijing 100084 (China); Tsinghua National Laboratory for Information Science and Technology, Beijing 100084 (China)

    2011-01-17

    We present a multipartite entanglement purification scheme in a Greenberger-Horne-Zeilinger state for electrons based on their spins and their charges. This scheme works for purification with two steps, i.e., bit-flip error correction and phase-flip error correction. By repeating these two steps, the parties in quantum communication can get some high-fidelity multipartite entangled electronic systems.

  1. Determination of beam intensity in a single step for IMRT inverse planning

    International Nuclear Information System (INIS)

    Chuang, Keh-Shih; Chen, Tzong-Jer; Kuo, Shan-Chi; Jan, Meei-Ling; Hwang, Ing-Ming; Chen, Sharon; Lin, Ying-Chuan; Wu, Jay

    2003-01-01

    In intensity modulated radiotherapy (IMRT), targets are treated by multiple beams at different orientations each with spatially-modulated beam intensities. This approach spreads the normal tissue dose to a greater volume and produces a higher dose conformation to the target. In general, inverse planning is used for IMRT treatment planning. The inverse planning requires iterative calculation of dose distribution in order to optimize the intensity profile for each beam and is very computation intensive. In this paper, we propose a single-step method utilizing a figure of merit (FoM) to estimate the beam intensities for IMRT treatment planning. The FoM of a ray is defined as the ratio between the delivered tumour dose and normal tissue dose and is a good index for the dose efficacy of the ray. To maximize the beam utility, it is natural to irradiate the tumour with intensity of each ray proportional to the value of the FoM. The nonuniform beam intensity profiles are then fixed and the weights of the beam are determined iteratively in order to yield a uniform tumour dose. In this study, beams are employed at equispaced angles around the patient. Each beam with its field size that just covers the tumour is divided into a fixed number of beamlets. The FoM is calculated for each beamlet and this value is assigned to be the beam intensity. Various weighting factors are incorporated in the FoM computation to accommodate different clinical considerations. Two clinical datasets are used to test the feasibility of the algorithm. The resultant dose-volume histograms of this method are presented and compared to that of conformal therapy. Preliminary results indicate that this method reduces the critical organ doses at a small expense of uniformity in tumour dose distribution. This method estimates the beam intensity in one single step and the computation time is extremely fast and can be finished in less than one minute using a regular PC

  2. Single-Step Seeded-Growth of Graphene Nanoribbons (GNRs) via Plasma-Enhanced Chemical Vapor Deposition (PECVD)

    Science.gov (United States)

    Hsu, C.-C.; Yang, K.; Tseng, W.-S.; Li, Yiliang; Li, Yilun; Tour, J. M.; Yeh, N.-C.

    One of the main challenges in the fabrication of GNRs is achieving large-scale low-cost production with high quality. Current techniques, including lithography and unzipped carbon nanotubes, are not suitable for mass production. We have recently developed a single-step PECVD growth process of high-quality graphene sheets without any active heating. By adding some substituted aromatic as seeding molecules, we are able to rapidly grow GNRs vertically on various transition-metal substrates. The morphology and electrical properties of the GNRs are dependent on the growth parameters such as the growth time, gas flow and species of the seeding molecules. On the other hand, all GNRs exhibit strong infrared and optical absorption. From studies of the Raman spectra, scanning electron microscopic images, and x-ray/ultraviolet photoelectron spectra of these GNRs as functions of the growth parameters, we propose a model for the growth mechanism. Our findings suggest that our approach opens up a pathway to large-scale, inexpensive production of GNRs for applications to supercapacitors and solar cells. This work was supported by the Grubstake Award and NSF through IQIM at Caltech.

  3. Molecular Doping of the Hole-Transporting Layer for Efficient, Single-Step Deposited Colloidal Quantum Dot Photovoltaics

    KAUST Repository

    Kirmani, Ahmad R.

    2017-07-31

    Employment of thin perovskite shells and metal halides as surface-passivants for colloidal quantum dots (CQDs) have been important, recent developments in CQD optoelectronics. These have opened the route to single-step deposited high-performing CQD solar cells. These promising architectures employ a QD hole-transporting layer (HTL) whose intrinsically shallow Fermi level (EF) restricts band-bending at maximum power-point during solar cell operation limiting charge collection. Here, we demonstrate a generalized approach to effectively balance band-edge energy levels of the main CQD absorber and charge-transport layer for these high-performance solar cells. Briefly soaking the QD HTL in a solution of the metal-organic p-dopant, molybdenum tris(1-(trifluoroacetyl)-2-(trifluoromethyl)ethane-1,2-dithiolene), effectively deepens its Fermi level, resulting in enhanced band bending at the HTL:absorber junction. This blocks the back-flow of photo-generated electrons, leading to enhanced photocurrent and fill factor compared to undoped devices. We demonstrate 9.0% perovskite-shelled and 9.5% metal-halide-passivated CQD solar cells, both achieving ca. 10% relative enhancements over undoped baselines.

  4. Single step preparation of NdFeB alloy by magnesiothermic reduction-diffusion process

    International Nuclear Information System (INIS)

    Singha, Vinay Kant; Surendranathana, A.O.; John Berchmans, L.

    2014-01-01

    Magnesiothermic reduction is a new approach to produce the NdFeB alloy on a commercial scale. Similar studies were conducted for the preparation of LaNi 5 and SmCo 5 using magnesium as the reductant. In the present investigation NdFeB Hard magnetic bulk materials were synthesized by metallothermic 'Reduction – Diffusion (R-D) Process' using Magnesium as a reductant. For this process oxide precursors of Nd, Fe and B were blended with flux (LiCl/CaCl 2 ) and Mg chips were sandwiched in alternate layers. Thermal analysis (TGA/DTA) was carried out to find the dissociation and decomposition temperature of the reactants. The phase analysis, structure, and elemental composition were assessed by X-ray diffraction (XRD) and electron dispersive spectrometry (EDS). The infrared (IR) spectra were recorded by Fourier transform infrared spectrometer (FTIR). The morphological features and particle size was assessed by scanning electron microscope (SEM). The magnetic behaviour of the alloy was assessed using electron paramagnetic resonance (EPR) and vibratory sample magnetometer (VSM). From these studies it has been concluded that the NdFeB magnetic particles can be prepared using magnesium as the reductant. The process is faster and consumes very less amount of energy for the completion as compared to conventional calciothermic reduction process. Traces of MgO were detected in the alloy which increases the perpendicular anisotropy, thus increasing the coercivity of the material

  5. Development of a Single-Step Subtraction Method for Eukaryotic 18S and 28S Ribonucleic Acids

    Directory of Open Access Journals (Sweden)

    Marie J. Archer

    2011-01-01

    Full Text Available The abundance of mammalian 18S and 28S ribosomal RNA can decrease the detection sensitivity of bacterial or viral targets in complex host-pathogen mixtures. A method to capture human RNA in a single step was developed and characterized to address this issue. For this purpose, capture probes were covalently attached to magnetic microbeads using a dendrimer linker and the solid phase was tested using rat thymus RNA (mammalian components with Escherichia coli RNA (bacterial target as a model system. Our results indicated that random capture probes demonstrated better performance than specific ones presumably by increasing the number of possible binding sites, and the use of a tetrame-thylammonium-chloride (TMA-Cl- based buffer for the hybridization showed a beneficial effect in the selectivity. The subtraction efficiency determined through real-time RT-PCR revealed capture-efficiencies comparable with commercially available enrichment kits. The performance of the solid phase can be further fine tuned by modifying the annealing time and temperature.

  6. LAT Perspectives in Detection of High Energy Cosmic Ray Electrons

    International Nuclear Information System (INIS)

    Moiseev, Alexander; Ormes, J.F.; Funk, Stefan

    2007-01-01

    The LAT science objectives and capabilities in the detection of high energy electrons in the energy range from 20 GeV to ∼1.5 TeV are presented. LAT simulations are used to establish the event selections. It is found that maintaining the efficiency of electron detection at the level of 30%, the residual hadron contamination does not exceed 2-3% of the electron flux. It is expected to collect ∼ ten million of electrons with the energy above 20 GeV for one year of observation. Precise spectrum reconstruction with collected electron statistics opens the unique opportunity to investigate several important problems such as models of IC radiation, revealing the signatures of nearby sources such as high energy cutoff in the electron spectrum, testing the propagation model, and search for KKDM particles decay through their contribution to the electron spectrum

  7. Electronic neutron sensor based on coincidence detection

    International Nuclear Information System (INIS)

    Barelaud, B.; Decossas, J.L.; Mokhtari, F.; Vareille, J.C.

    1996-01-01

    The last symposium on neutron dosimetry which took place in Paris in November 1995 have shown again that it doesn't exist any individual active neutron dosemeter. The state of art on electronic device, the needs of the nuclear power industry in individual neutron monitoring and the new trends of The last symposium on neutron dosimetry which took place in Paris in November 1995 have shown again that it doesn't exist any individual active neutron dosemeter. The state of art on electronic device, the needs of the nuclear power industry in individual neutron monitoring and the new trends of researches were presented. They confirm the relevance of our studies in progress in the C2M team of the University of Limoges. The aim of this work is to realize an individual electronic neutron dosemeter. The device in the progress of being development will operate either as a dosemeter or as ratemeter giving H p (10) and H p (10) either as a spectrometer permitting to characterize the primary neutron beam. (author)

  8. Electronic spectral detection in liquid chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Biggs, Wilton R. [ChevronTexaco Chemical Co., P. O. Box 1627, Richmond, CA 94802 (United States); Fetzer, John C. [Fetzpahs Consulting, 1283 Santa Fe St., Hercules, CA 94547 (United States)

    2002-07-01

    The use of absorbance and fluorescence spectrometers as liquid chromatography detectors is described. These detectors offer sensitive detection that can also identify the peaks in a chromatogram. Many examples, mainly from the separation of polycyclic aromatic hydrocarbons, are given that show the selectivity and usefulness of these detectors. (orig.)

  9. Incorporation of causative quantitative trait nucleotides in single-step GBLUP.

    Science.gov (United States)

    Fragomeni, Breno O; Lourenco, Daniela A L; Masuda, Yutaka; Legarra, Andres; Misztal, Ignacy

    2017-07-26

    Much effort is put into identifying causative quantitative trait nucleotides (QTN) in animal breeding, empowered by the availability of dense single nucleotide polymorphism (SNP) information. Genomic selection using traditional SNP information is easily implemented for any number of genotyped individuals using single-step genomic best linear unbiased predictor (ssGBLUP) with the algorithm for proven and young (APY). Our aim was to investigate whether ssGBLUP is useful for genomic prediction when some or all QTN are known. Simulations included 180,000 animals across 11 generations. Phenotypes were available for all animals in generations 6 to 10. Genotypes for 60,000 SNPs across 10 chromosomes were available for 29,000 individuals. The genetic variance was fully accounted for by 100 or 1000 biallelic QTN. Raw genomic relationship matrices (GRM) were computed from (a) unweighted SNPs, (b) unweighted SNPs and causative QTN, (c) SNPs and causative QTN weighted with results obtained with genome-wide association studies, (d) unweighted SNPs and causative QTN with simulated weights, (e) only unweighted causative QTN, (f-h) as in (b-d) but using only the top 10% causative QTN, and (i) using only causative QTN with simulated weight. Predictions were computed by pedigree-based BLUP (PBLUP) and ssGBLUP. Raw GRM were blended with 1 or 5% of the numerator relationship matrix, or 1% of the identity matrix. Inverses of GRM were obtained directly or with APY. Accuracy of breeding values for 5000 genotyped animals in the last generation with PBLUP was 0.32, and for ssGBLUP it increased to 0.49 with an unweighted GRM, 0.53 after adding unweighted QTN, 0.63 when QTN weights were estimated, and 0.89 when QTN weights were based on true effects known from the simulation. When the GRM was constructed from causative QTN only, accuracy was 0.95 and 0.99 with blending at 5 and 1%, respectively. Accuracies simulating 1000 QTN were generally lower, with a similar trend. Accuracies using the

  10. Complex single step skull reconstruction in Gorham's disease - a technical report and review of the literature.

    Science.gov (United States)

    Ohla, Victoria; Bayoumi, Ahmed B; Hefty, Markus; Anderson, Matthew; Kasper, Ekkehard M

    2015-03-11

    Gorham's disease is a rare osteolytic disorder characterized by progressive resorption of bone and replacement of osseous matrix by a proliferative non-neoplastic vascular or lymphatic tissue. A standardized treatment protocol has not yet been defined due to the unpredictable natural history of the disease and variable clinical presentations. No single treatment has proven to be superior in arresting the course of the disease. Trials have included surgery, radiation and medical therapies using drugs such as calcium salts, vitamin D supplements and hormones. We report on our advantageous experience in the management of this osteolyic disorder in a case when it affected only the skull vault. A brief review of pertinent literature about Gorham's disease with skull involvement is provided. A 25-year-old Caucasian male presented with a skull depression over the left fronto-temporal region. He noticed progressive enlargement of the skull defect associated with local pain and mild headache. Physical examination revealed a tender palpable depression of the fronto-temporal convexity. Conventional X-ray of the skull showed widespread loss of bone substance. Subsequent CT scans showed features of patchy erosions indicative of an underlying osteolysis. MRI also revealed marginal enhancement at the site of the defect. The patient was in need of a pathological diagnosis as well as complex reconstruction of the afflicted area. A density graded CT scan was done to determine the variable degrees of osteolysis and a custom made allograft was designed for cranioplasty preoperatively to allow for a single step excisional craniectomy with synchronous skull repair. Gorham's disease was diagnosed based on histopathological examination. No neurological deficit or wound complications were reported postoperatively. Over a two-year follow up period, the patient had no evidence of local recurrence or other systemic involvement. A single step excisional craniectomy and cranioplasty can be an

  11. Single step production of Cas9 mRNA for zygote injection.

    Science.gov (United States)

    Redel, Bethany K; Beaton, Benjamin P; Spate, Lee D; Benne, Joshua A; Murphy, Stephanie L; O'Gorman, Chad W; Spate, Anna M; Prather, Randall S; Wells, Kevin D

    2018-03-01

    Production of Cas9 mRNA in vitro typically requires the addition of a 5´ cap and 3´ polyadenylation. A plasmid was constructed that harbored the T7 promoter followed by the EMCV IRES and a Cas9 coding region. We hypothesized that the use of the metastasis associated lung adenocarcinoma transcript 1 (Malat1) triplex structure downstream of an IRES/Cas9 expression cassette would make polyadenylation of in vitro produced mRNA unnecessary. A sequence from the mMalat1 gene was cloned downstream of the IRES/Cas9 cassette described above. An mRNA concentration curve was constructed with either commercially available Cas9 mRNA or the IRES/ Cas9/triplex, by injection into porcine zygotes. Blastocysts were genotyped to determine if differences existed in the percent of embryos modified. The concentration curve identified differences due to concentration and RNA type injected. Single step production of Cas9 mRNA provides an alternative source of Cas9 for use in zygote injections.

  12. Evaluating tamsulosin hydrochloride-released microparticles prepared using single-step matrix coating.

    Science.gov (United States)

    Maeda, Atsushi; Shinoda, Tatsuki; Ito, Naoki; Baba, Keizo; Oku, Naoto; Mizumoto, Takao

    2011-04-15

    The objective of the present study was to determine the optimum composition for sustained-release of tamsulosin hydrochloride from microparticles intended for orally disintegrating tablets. Microparticles were prepared from an aqueous ethylcellulose dispersion (Aquacoa®), and an aqueous copolymer based on ethyl acrylate and methyl methacrylate dispersion (Eudragit®) NE30D), with microcrystalline cellulose as core particles with a fluidized bed coating process. Prepared microparticles were about 200 μm diameter and spherical. The microparticles were evaluated for in vitro drug release and in vivo absorption to assess bioequivalence in a commercial product, Harnal® pellets. The optimum ratio of Aquacoat® and Eudragit® NE30D in the matrix was 9:1. We observed similar drug release profiles in microparticles and Harnal® pellets. Higuchi model analysis of the in vitro drug release from microparticles was linear up to 80% release, typical of Fickian diffusion sustained-release profile. The in vivo absorption properties from microparticles were comparable to Harnal® pellets, and there was a linear relationship between in vitro drug release and in vivo drug release. In conclusion, this development produces microparticles in single-step coating, that provided a sustained-release of tamsulosin hydrochloride comparable to Harnal® pellets. Copyright © 2011 Elsevier B.V. All rights reserved.

  13. Single-step laser-based fabrication and patterning of cell-encapsulated alginate microbeads

    International Nuclear Information System (INIS)

    Kingsley, D M; Dias, A D; Corr, D T; Chrisey, D B

    2013-01-01

    Alginate can be used to encapsulate mammalian cells and for the slow release of small molecules. Packaging alginate as microbead structures allows customizable delivery for tissue engineering, drug release, or contrast agents for imaging. However, state-of-the-art microbead fabrication has a limited range in achievable bead sizes, and poor control over bead placement, which may be desired to localize cellular signaling or delivery. Herein, we present a novel, laser-based method for single-step fabrication and precise planar placement of alginate microbeads. Our results show that bead size is controllable within 8%, and fabricated microbeads can remain immobilized within 2% of their target placement. Demonstration of this technique using human breast cancer cells shows that cells encapsulated within these microbeads survive at a rate of 89.6%, decreasing to 84.3% after five days in culture. Infusing rhodamine dye into microbeads prior to fluorescent microscopy shows their 3D spheroidal geometry and the ability to sequester small molecules. Microbead fabrication and patterning is compatible with conventional cellular transfer and patterning by laser direct-write, allowing location-based cellular studies. While this method can also be used to fabricate microbeads en masse for collection, the greatest value to tissue engineering and drug delivery studies and applications lies in the pattern registry of printed microbeads. (paper)

  14. Single step, pH induced gold nanoparticle chain formation in lecithin/water system.

    Science.gov (United States)

    Sharma, Damyanti

    2013-07-01

    Gold nanoparticle (AuNP) chains have been formed by a single step method in a lecithin/water system where lecithin itself plays the role of a reductant and a template for AuNP chain formation. Two preparative strategies were explored: (1) evaporating lecithin solution with aqueous gold chloride (HAuCl4) at different pHs and (2) dispersing lecithin vesicles in aqueous HAuCl4 solutions of various pHs in the range of 2.5-11.3. In method 1, at initial pH 2.5, 20-50 nm AuNPs are found attached to lecithin vesicles. When pH is raised to 5.5 there are no vesicles present and 20 nm monodisperse particles are found aggregating. Chain formation of fine nanoparticles (3-5 nm) is observed from neutral to basic pH, between 6.5-10.3 The chains formed are hundreds of nanometers to micrometer long and are usually 2-3 nanoparticles wide. On further increasing pH to 11.3, particles form disk-like or raft-like structures. When method (ii) was used a little chain formation was observed. Most of the nanoparticles formed were found either sitting together as raft like structures or scattered on lecithin structures. Copyright © 2013 Elsevier B.V. All rights reserved.

  15. Process analysis and modeling of a single-step lutein extraction method for wet microalgae.

    Science.gov (United States)

    Gong, Mengyue; Wang, Yuruihan; Bassi, Amarjeet

    2017-11-01

    Lutein is a commercial carotenoid with potential health benefits. Microalgae are alternative sources for the lutein production in comparison to conventional approaches using marigold flowers. In this study, a process analysis of a single-step simultaneous extraction, saponification, and primary purification process for free lutein production from wet microalgae biomass was carried out. The feasibility of binary solvent mixtures for wet biomass extraction was successfully demonstrated, and the extraction kinetics of lutein from chloroplast in microalgae were first evaluated. The effects of types of organic solvent, solvent polarity, cell disruption method, and alkali and solvent usage on lutein yields were examined. A mathematical model based on Fick's second law of diffusion was applied to model the experimental data. The mass transfer coefficients were used to estimate the extraction rates. The extraction rate was found more significantly related with alkali ratio to solvent than to biomass. The best conditions for extraction efficiency were found to be pre-treatment with ultrasonication at 0.5 s working cycle per second, react 0.5 h in 0.27 L/g solvent to biomass ratio, and 1:3 ether/ethanol (v/v) with 1.25 g KOH/L. The entire process can be controlled within 1 h and yield over 8 mg/g lutein, which is more economical for scale-up.

  16. Pharmaceutical 3D printing: Design and qualification of a single step print and fill capsule.

    Science.gov (United States)

    Smith, Derrick M; Kapoor, Yash; Klinzing, Gerard R; Procopio, Adam T

    2018-06-10

    Fused deposition modeling (FDM) 3D printing (3DP) has a potential to change how we envision manufacturing in the pharmaceutical industry. A more common utilization for FDM 3DP is to build upon existing hot melt extrusion (HME) technology where the drug is dispersed in the polymer matrix. However, reliable manufacturing of drug-containing filaments remains a challenge along with the limitation of active ingredients which can sustain the processing risks involved in the HME process. To circumvent this obstacle, a single step FDM 3DP process was developed to manufacture thin-walled drug-free capsules which can be filled with dry or liquid drug product formulations. Drug release from these systems is governed by the combined dissolution of the FDM capsule 'shell' and the dosage form encapsulated in these shells. To prepare the shells, the 3D printer files (extension '.gcode') were modified by creating discrete zones, so-called 'zoning process', with individual print parameters. Capsules printed without the zoning process resulted in macroscopic print defects and holes. X-ray computed tomography, finite element analysis and mechanical testing were used to guide the zoning process and printing parameters in order to manufacture consistent and robust capsule shell geometries. Additionally, dose consistencies of drug containing liquid formulations were investigated in this work. Copyright © 2018 Elsevier B.V. All rights reserved.

  17. Single-step gas phase synthesis of stable iron aluminide nanoparticles with soft magnetic properties

    Energy Technology Data Exchange (ETDEWEB)

    Vernieres, Jerome, E-mail: Jerome.vernieres@oist.jp; Benelmekki, Maria; Kim, Jeong-Hwan; Grammatikopoulos, Panagiotis; Diaz, Rosa E. [Nanoparticles by Design Unit, Okinawa Institute of Science and Technology (OIST) Graduate University, 1919-1 Tancha, Onna Son, Okinawa 904-0495 (Japan); Bobo, Jean-François [Centre d’Elaboration de Materiaux et d’Etudes Structurales (CEMES), 29 rue Jeanne Marvig, 31055 Toulouse Cedex 4 (France); Sowwan, Mukhles, E-mail: Mukhles@oist.jp [Nanoparticles by Design Unit, Okinawa Institute of Science and Technology (OIST) Graduate University, 1919-1 Tancha, Onna Son, Okinawa 904-0495 (Japan); Nanotechnology Research Laboratory, Al-Quds University, P.O. Box 51000, East Jerusalem, Palestine (Country Unknown)

    2014-11-01

    Soft magnetic alloys at the nanoscale level have long generated a vivid interest as candidate materials for technological and biomedical purposes. Consequently, controlling the structure of bimetallic nanoparticles in order to optimize their magnetic properties, such as high magnetization and low coercivity, can significantly boost their potential for related applications. However, traditional synthesis methods stumble upon the long standing challenge of developing true nanoalloys with effective control over morphology and stability against oxidation. Herein, we report on a single-step approach to the gas phase synthesis of soft magnetic bimetallic iron aluminide nanoparticles, using a versatile co-sputter inert gas condensation technique. This method allowed for precise morphological control of the particles; they consisted of an alloy iron aluminide crystalline core (DO{sub 3} phase) and an alumina shell, which reduced inter-particle interactions and also prevented further oxidation and segregation of the bimetallic core. Remarkably, the as-deposited alloy nanoparticles show interesting soft magnetic properties, in that they combine a high saturation magnetization (170 emu/g) and low coercivity (less than 20 Oe) at room temperature. Additional functionality is tenable by modifying the surface of the particles with a polymer, to ensure their good colloidal dispersion in aqueous environments.

  18. Structural Studies of Silver Nanoparticles Obtained Through Single-Step Green Synthesis

    Science.gov (United States)

    Prasad Peddi, Siva; Abdallah Sadeh, Bilal

    2015-10-01

    Green synthesis of silver Nanoparticles (AGNP's) has been the most prominent among the metallic nanoparticles for research for over a decade and half now due to both the simplicity of preparation and the applicability of biological species with extensive applications in medicine and biotechnology to reduce and trap the particles. The current article uses Eclipta Prostrata leaf extract as the biological species to cap the AGNP's through a single step process. The characterization data obtained was used for the analysis of the sample structure. The article emphasizes the disquisition of their shape and size of the lattice parameters and proposes a general scheme and a mathematical model for the analysis of their dependence. The data of the synthesized AGNP's has been used to advantage through the introduction of a structural shape factor for the crystalline nanoparticles. The properties of the structure of the AGNP's proposed and evaluated through a theoretical model was undeviating with the experimental consequences. This modus operandi gives scope for the structural studies of ultrafine particles prepared using biological methods.

  19. Single-step colloidal quantum dot films for infrared solar harvesting

    KAUST Repository

    Kiani, Amirreza

    2016-11-01

    Semiconductors with bandgaps in the near- to mid-infrared can harvest solar light that is otherwise wasted by conventional single-junction solar cell architectures. In particular, colloidal quantum dots (CQDs) are promising materials since they are cost-effective, processed from solution, and have a bandgap that can be tuned into the infrared (IR) via the quantum size effect. These characteristics enable them to harvest the infrared portion of the solar spectrum to which silicon is transparent. To date, IR CQD solar cells have been made using a wasteful and complex sequential layer-by-layer process. Here, we demonstrate ∼1 eV bandgap solar-harvesting CQD films deposited in a single step. By engineering a fast-drying solvent mixture for metal iodide-capped CQDs, we deposited active layers greater than 200 nm in thickness having a mean roughness less than 1 nm. We integrated these films into infrared solar cells that are stable in air and exhibit power conversion efficiencies of 3.5% under illumination by the full solar spectrum, and 0.4% through a simulated silicon solar cell filter.

  20. Transmission environmental scanning electron microscope with scintillation gaseous detection device.

    Science.gov (United States)

    Danilatos, Gerasimos; Kollia, Mary; Dracopoulos, Vassileios

    2015-03-01

    A transmission environmental scanning electron microscope with use of a scintillation gaseous detection device has been implemented. This corresponds to a transmission scanning electron microscope but with addition of a gaseous environment acting both as environmental and detection medium. A commercial type of low vacuum machine has been employed together with appropriate modifications to the detection configuration. This involves controlled screening of various emitted signals in conjunction with a scintillation gaseous detection device already provided with the machine for regular surface imaging. Dark field and bright field imaging has been obtained along with other detection conditions. With a progressive series of modifications and tests, the theory and practice of a novel type of microscopy is briefly shown now ushering further significant improvements and developments in electron microscopy as a whole. Copyright © 2014 Elsevier B.V. All rights reserved.

  1. Transmission environmental scanning electron microscope with scintillation gaseous detection device

    International Nuclear Information System (INIS)

    Danilatos, Gerasimos; Kollia, Mary; Dracopoulos, Vassileios

    2015-01-01

    A transmission environmental scanning electron microscope with use of a scintillation gaseous detection device has been implemented. This corresponds to a transmission scanning electron microscope but with addition of a gaseous environment acting both as environmental and detection medium. A commercial type of low vacuum machine has been employed together with appropriate modifications to the detection configuration. This involves controlled screening of various emitted signals in conjunction with a scintillation gaseous detection device already provided with the machine for regular surface imaging. Dark field and bright field imaging has been obtained along with other detection conditions. With a progressive series of modifications and tests, the theory and practice of a novel type of microscopy is briefly shown now ushering further significant improvements and developments in electron microscopy as a whole. - Highlights: • Novel scanning transmission electron microscopy (STEM) with an environmental scanning electron microscope (ESEM) called TESEM. • Use of the gaseous detection device (GDD) in scintillation mode that allows high resolution bright and dark field imaging in the TESEM. • Novel approach towards a unification of both vacuum and environmental conditions in both bulk/surface and transmission mode of electron microscopy

  2. 78 FR 35262 - Detection and Avoidance of Counterfeit Electronic Parts

    Science.gov (United States)

    2013-06-12

    ... experts and interested parties in Government and the private sector regarding the electronic parts... Avoidance of Counterfeit Electronic Parts AGENCY: Defense Acquisition Regulations System, Department of... interested parties in Government and the private sector about the requirements for detection and avoidance of...

  3. The Effect of Phosphoric Acid Pre-etching Times on Bonding Performance and Surface Free Energy with Single-step Self-etch Adhesives.

    Science.gov (United States)

    Tsujimoto, A; Barkmeier, W W; Takamizawa, T; Latta, M A; Miyazaki, M

    2016-01-01

    The purpose of this study was to evaluate the effect of phosphoric acid pre-etching times on shear bond strength (SBS) and surface free energy (SFE) with single-step self-etch adhesives. The three single-step self-etch adhesives used were: 1) Scotchbond Universal Adhesive (3M ESPE), 2) Clearfil tri-S Bond (Kuraray Noritake Dental), and 3) G-Bond Plus (GC). Two no pre-etching groups, 1) untreated enamel and 2) enamel surfaces after ultrasonic cleaning with distilled water for 30 seconds to remove the smear layer, were prepared. There were four pre-etching groups: 1) enamel surfaces were pre-etched with phosphoric acid (Etchant, 3M ESPE) for 3 seconds, 2) enamel surfaces were pre-etched for 5 seconds, 3) enamel surfaces were pre-etched for 10 seconds, and 4) enamel surfaces were pre-etched for 15 seconds. Resin composite was bonded to the treated enamel surface to determine SBS. The SFEs of treated enamel surfaces were determined by measuring the contact angles of three test liquids. Scanning electron microscopy was used to examine the enamel surfaces and enamel-adhesive interface. The specimens with phosphoric acid pre-etching showed significantly higher SBS and SFEs than the specimens without phosphoric acid pre-etching regardless of the adhesive system used. SBS and SFEs did not increase for phosphoric acid pre-etching times over 3 seconds. There were no significant differences in SBS and SFEs between the specimens with and without a smear layer. The data suggest that phosphoric acid pre-etching of ground enamel improves the bonding performance of single-step self-etch adhesives, but these bonding properties do not increase for phosphoric acid pre-etching times over 3 seconds.

  4. Comparison of single-step and two-step purified coagulants from Moringa oleifera seed for turbidity and DOC removal.

    Science.gov (United States)

    Sánchez-Martín, J; Ghebremichael, K; Beltrán-Heredia, J

    2010-08-01

    The coagulant proteins from Moringa oleifera purified with single-step and two-step ion-exchange processes were used for the coagulation of surface water from Meuse river in The Netherlands. The performances of the two purified coagulants and the crude extract were assessed in terms of turbidity and DOC removal. The results indicated that the optimum dosage of the single-step purified coagulant was more than two times higher compared to the two-step purified coagulant in terms of turbidity removal. And the residual DOC in the two-step purified coagulant was lower than in single-step purified coagulant or crude extract. (c) 2010 Elsevier Ltd. All rights reserved.

  5. Neuronal synchrony detection on single-electron neural networks

    International Nuclear Information System (INIS)

    Oya, Takahide; Asai, Tetsuya; Kagaya, Ryo; Hirose, Tetsuya; Amemiya, Yoshihito

    2006-01-01

    Synchrony detection between burst and non-burst spikes is known to be one functional example of depressing synapses. Kanazawa et al. demonstrated synchrony detection with MOS depressing synapse circuits. They found that the performance of a network with depressing synapses that discriminates between burst and random input spikes increases non-monotonically as the static device mismatch is increased. We designed a single-electron depressing synapse and constructed the same network as in Kanazawa's study to develop noise-tolerant single-electron circuits. We examined the temperature characteristics and explored possible architecture that enables single-electron circuits to operate at T > 0 K

  6. A novel single-step synthesis of N-doped TiO2 via a sonochemical method

    International Nuclear Information System (INIS)

    Wang, Xi-Kui; Wang, Chen; Guo, Wei-Lin; Wang, Jin-Gang

    2011-01-01

    Graphical abstract: The N-doped anatase TiO 2 nanoparticles were synthesized by sonochemical method. The as-prepared sample is characterized by XRD, TEM, XPS and UV-Vis DRS. The photocatalytic activity of the photocatalyst was evaluated by the photodegradation of an azo dye direct sky blue 5B. Highlights: → A novel singal-step sonochemical synthesis method for the preparation of anatase N-doped TiO 2 nanocrystalline at low temperature has been devoleped. → The as-prepared sample is characterized by XRD, TEM, XPS and UV-Vis DRS. → The photodegradation of azo dye direct sky blue 5 showed that the N-doped TiO 2 catalyst is of high visible-light photocatalytic activity. -- Abstract: A novel single-step synthetic method for the preparation of anatase N-doped TiO 2 nanocrystalline at low temperature has been devoleped. The N-doped anatase TiO 2 nanoparticles were synthesized by sonication of the solution of tetraisopropyl titanium and urea in water and isopropyl alcohol at 80 o C for 150 min. The as-prepared sample was characterized by X-ray diffraction, transmission electron microscopy, X-ray photoelectron spectroscopy and UV-vis absorption spectrum. The product structure depends on the reaction temperature and reaction time. The photocatalytic activity of the as-prepared photocatalyst was evaluated via the photodegradation of an azo dye direct sky blue 5B. The results show that the N-doped TiO 2 nanocrystalline prepared via sonication exhibit an excellent photocatalytic activity under UV light and simulated sunlight.

  7. Single-step reinitialization and extending algorithms for level-set based multi-phase flow simulations

    Science.gov (United States)

    Fu, Lin; Hu, Xiangyu Y.; Adams, Nikolaus A.

    2017-12-01

    We propose efficient single-step formulations for reinitialization and extending algorithms, which are critical components of level-set based interface-tracking methods. The level-set field is reinitialized with a single-step (non iterative) "forward tracing" algorithm. A minimum set of cells is defined that describes the interface, and reinitialization employs only data from these cells. Fluid states are extrapolated or extended across the interface by a single-step "backward tracing" algorithm. Both algorithms, which are motivated by analogy to ray-tracing, avoid multiple block-boundary data exchanges that are inevitable for iterative reinitialization and extending approaches within a parallel-computing environment. The single-step algorithms are combined with a multi-resolution conservative sharp-interface method and validated by a wide range of benchmark test cases. We demonstrate that the proposed reinitialization method achieves second-order accuracy in conserving the volume of each phase. The interface location is invariant to reapplication of the single-step reinitialization. Generally, we observe smaller absolute errors than for standard iterative reinitialization on the same grid. The computational efficiency is higher than for the standard and typical high-order iterative reinitialization methods. We observe a 2- to 6-times efficiency improvement over the standard method for serial execution. The proposed single-step extending algorithm, which is commonly employed for assigning data to ghost cells with ghost-fluid or conservative interface interaction methods, shows about 10-times efficiency improvement over the standard method while maintaining same accuracy. Despite their simplicity, the proposed algorithms offer an efficient and robust alternative to iterative reinitialization and extending methods for level-set based multi-phase simulations.

  8. Lighnting detection and tracking with consumer electronics

    Science.gov (United States)

    Kamau, Gilbert; van de Giesen, Nick

    2015-04-01

    Lightning data is not only important for environment and weather monitoring but also for safety purposes. The AS3935 Franklin Lightning Sensor (AMS, Unterpremstaetten, Austria) is a lightning sensor developed for inclusion in consumer electronics such as watches and mobile phones. The AS3935 is small (4mmx4mm) and relatively cost effective (Eu 5). The downside is that only rough distance estimates are provided, as average power is assumed for every lightning strike. To be able to track lightning, a network of devices that monitor and keep track of occurrences of lightning strikes was developed. A communication interface was established between the sensors, a data logging circuit and a microcontroller. The digital outputs of the lightning sensor and data from a GPS are processed by the microcontroller and logged onto an SD card. The interface program enables sampling parameters such as distance from the lightning strike, time of strike occurrence and geographical location of the device. For archiving and analysis purposes, the data can be transferred from the SD card to a PC and results displayed using a graphical user interface program. Data gathered shows that the device can track the frequency and movement of lightning strikes in an area. The device has many advantages as compared to other lightning sensor stations in terms of huge memory, lower power consumption, small size, greater portability and lower cost. The devices were used in a network around Nairobi, Kenya. Through multi-lateration, lightning strikes could be located with a RMSE of 2 km or better.

  9. Single step biotransformation of corn oil phytosterols to boldenone by a newly isolated Pseudomonas aeruginosa

    Directory of Open Access Journals (Sweden)

    Mohamed Eisa

    2016-09-01

    Full Text Available A new potent Pseudomonas aeruginosa isolate capable for biotransformation of corn oil phytosterol (PS to 4-androstene-3, 17-dione (AD, testosterone (T and boldenone (BOL was identified by phenotypic analysis and 16S rRNA gene sequencing. Sequential statistical strategy was used to optimize the biotransformation process mainly concerning BOL using Factorial design and response surface methodology (RSM. The production of BOL in single step microbial biotransformation from corn oil phytosterols by P. aeruginosa was not previously reported. Results showed that the pH concentration of the medium, (NH42SO4 and KH2PO4 were the most significant factors affecting BOL production. By analyzing the statistical model of three-dimensional surface plot, BOL production increased from 36.8% to 42.4% after the first step of optimization, and the overall biotransformation increased to 51.9%. After applying the second step of the sequential statistical strategy BOL production increased to 53.6%, and the overall biotransformation increased to 91.9% using the following optimized medium composition (g/l distilled water (NH42SO4, 2; KH2PO4, 4; Na2HPO4. 1; MgSO4·7H2O, 0.3; NaCl, 0.1; CaCl2·2H2O, 0.1; FeSO4·7H2O, 0.001; ammonium acetate 0.001; Tween 80, 0.05%; corn oil 0.5%; 8-hydroxyquinoline 0.016; pH 8; 200 rpm agitation speed and incubation time 36 h at 30 °C. Validation experiments proved the adequacy and accuracy of model, and the results showed the predicted value agreed well with the experimental values.

  10. Single-Step BLUP with Varying Genotyping Effort in Open-Pollinated Picea glauca.

    Science.gov (United States)

    Ratcliffe, Blaise; El-Dien, Omnia Gamal; Cappa, Eduardo P; Porth, Ilga; Klápště, Jaroslav; Chen, Charles; El-Kassaby, Yousry A

    2017-03-10

    Maximization of genetic gain in forest tree breeding programs is contingent on the accuracy of the predicted breeding values and precision of the estimated genetic parameters. We investigated the effect of the combined use of contemporary pedigree information and genomic relatedness estimates on the accuracy of predicted breeding values and precision of estimated genetic parameters, as well as rankings of selection candidates, using single-step genomic evaluation (HBLUP). In this study, two traits with diverse heritabilities [tree height (HT) and wood density (WD)] were assessed at various levels of family genotyping efforts (0, 25, 50, 75, and 100%) from a population of white spruce ( Picea glauca ) consisting of 1694 trees from 214 open-pollinated families, representing 43 provenances in Québec, Canada. The results revealed that HBLUP bivariate analysis is effective in reducing the known bias in heritability estimates of open-pollinated populations, as it exposes hidden relatedness, potential pedigree errors, and inbreeding. The addition of genomic information in the analysis considerably improved the accuracy in breeding value estimates by accounting for both Mendelian sampling and historical coancestry that were not captured by the contemporary pedigree alone. Increasing family genotyping efforts were associated with continuous improvement in model fit, precision of genetic parameters, and breeding value accuracy. Yet, improvements were observed even at minimal genotyping effort, indicating that even modest genotyping effort is effective in improving genetic evaluation. The combined utilization of both pedigree and genomic information may be a cost-effective approach to increase the accuracy of breeding values in forest tree breeding programs where shallow pedigrees and large testing populations are the norm. Copyright © 2017 Ratcliffe et al.

  11. Method for making a single-step etch mask for 3D monolithic nanostructures

    International Nuclear Information System (INIS)

    Grishina, D A; Harteveld, C A M; Vos, W L; Woldering, L A

    2015-01-01

    Current nanostructure fabrication by etching is usually limited to planar structures as they are defined by a planar mask. The realization of three-dimensional (3D) nanostructures by etching requires technologies beyond planar masks. We present a method for fabricating a 3D mask that allows one to etch three-dimensional monolithic nanostructures using only CMOS-compatible processes. The mask is written in a hard-mask layer that is deposited on two adjacent inclined surfaces of a Si wafer. By projecting in a single step two different 2D patterns within one 3D mask on the two inclined surfaces, the mutual alignment between the patterns is ensured. Thereby after the mask pattern is defined, the etching of deep pores in two oblique directions yields a three-dimensional structure in Si. As a proof of concept we demonstrate 3D mask fabrication for three-dimensional diamond-like photonic band gap crystals in silicon. The fabricated crystals reveal a broad stop gap in optical reflectivity measurements. We propose how 3D nanostructures with five different Bravais lattices can be realized, namely cubic, tetragonal, orthorhombic, monoclinic and hexagonal, and demonstrate a mask for a 3D hexagonal crystal. We also demonstrate the mask for a diamond-structure crystal with a 3D array of cavities. In general, the 2D patterns on the different surfaces can be completely independently structured and still be in perfect mutual alignment. Indeed, we observe an alignment accuracy of better than 3.0 nm between the 2D mask patterns on the inclined surfaces, which permits one to etch well-defined monolithic 3D nanostructures. (paper)

  12. Single-Step BLUP with Varying Genotyping Effort in Open-Pollinated Picea glauca

    Directory of Open Access Journals (Sweden)

    Blaise Ratcliffe

    2017-03-01

    Full Text Available Maximization of genetic gain in forest tree breeding programs is contingent on the accuracy of the predicted breeding values and precision of the estimated genetic parameters. We investigated the effect of the combined use of contemporary pedigree information and genomic relatedness estimates on the accuracy of predicted breeding values and precision of estimated genetic parameters, as well as rankings of selection candidates, using single-step genomic evaluation (HBLUP. In this study, two traits with diverse heritabilities [tree height (HT and wood density (WD] were assessed at various levels of family genotyping efforts (0, 25, 50, 75, and 100% from a population of white spruce (Picea glauca consisting of 1694 trees from 214 open-pollinated families, representing 43 provenances in Québec, Canada. The results revealed that HBLUP bivariate analysis is effective in reducing the known bias in heritability estimates of open-pollinated populations, as it exposes hidden relatedness, potential pedigree errors, and inbreeding. The addition of genomic information in the analysis considerably improved the accuracy in breeding value estimates by accounting for both Mendelian sampling and historical coancestry that were not captured by the contemporary pedigree alone. Increasing family genotyping efforts were associated with continuous improvement in model fit, precision of genetic parameters, and breeding value accuracy. Yet, improvements were observed even at minimal genotyping effort, indicating that even modest genotyping effort is effective in improving genetic evaluation. The combined utilization of both pedigree and genomic information may be a cost-effective approach to increase the accuracy of breeding values in forest tree breeding programs where shallow pedigrees and large testing populations are the norm.

  13. The Accuracy and Bias of Single-Step Genomic Prediction for Populations Under Selection

    Directory of Open Access Journals (Sweden)

    Wan-Ling Hsu

    2017-08-01

    Full Text Available In single-step analyses, missing genotypes are explicitly or implicitly imputed, and this requires centering the observed genotypes using the means of the unselected founders. If genotypes are only available for selected individuals, centering on the unselected founder mean is not straightforward. Here, computer simulation is used to study an alternative analysis that does not require centering genotypes but fits the mean μg of unselected individuals as a fixed effect. Starting with observed diplotypes from 721 cattle, a five-generation population was simulated with sire selection to produce 40,000 individuals with phenotypes, of which the 1000 sires had genotypes. The next generation of 8000 genotyped individuals was used for validation. Evaluations were undertaken with (J or without (N μg when marker covariates were not centered; and with (JC or without (C μg when all observed and imputed marker covariates were centered. Centering did not influence accuracy of genomic prediction, but fitting μg did. Accuracies were improved when the panel comprised only quantitative trait loci (QTL; models JC and J had accuracies of 99.4%, whereas models C and N had accuracies of 90.2%. When only markers were in the panel, the 4 models had accuracies of 80.4%. In panels that included QTL, fitting μg in the model improved accuracy, but had little impact when the panel contained only markers. In populations undergoing selection, fitting μg in the model is recommended to avoid bias and reduction in prediction accuracy due to selection.

  14. Detection of secondary electrons with pixelated hybrid semiconductor detectors

    International Nuclear Information System (INIS)

    Gebert, Ulrike Sonja

    2011-01-01

    Within the scope of this thesis, secondary electrons were detected with a pixelated semiconductor detector named Timepix. The Timepix detector consists of electronics and a sensor made from a semiconductor material. The connection of sensor and electronics is done for each pixel individually using bump bonds. Electrons with energies above 3 keV can be detected with the sensor. One electron produces a certain amount of electron-hole pairs according to its energy. The charge then drifts along an electric field to the pixel electronics, where it induces an electric signal. Even without a sensor it is possible to detect an electric signal from approximately 1000 electrons directly in the pixel electronics. Two different detector systems to detect secondary electrons using the Timepix detector were investigated during this thesis. First of all, a hybrid photon detector (HPD) was used to detect single photoelectrons. The HPD consists of a vacuum vessel with an entrance window and a cesium iodine photocathode at the inner surface of the window. Photoelectrons are released from the photocathode by incident light and are accelerated in an electric field towards the Timepix detector, where the point of interaction and the arrival time of the electron is determined. With a proximity focusing setup, a time resolution of 12 ns (with an acceleration voltage of 20 kV between photocathode and Timepix detector) was obtained. The HPD examined in this thesis showed a strong dependence of the dark rate form the acceleration voltage and the pressure in the vacuum vessel. At a pressure of few 10 -5 mbar and an acceleration voltage of 20 kV, the dark rate was about 800 Hz per mm 2 area of the read out photocathode. One possibility to reduce the dark rate is to identify ion feedback events. With a slightly modified setup it was possible to reduce the dark rate to 0.5 Hz/mm 2 . To achieve this, a new photocathode was mounted in a shorter distance to the detector. The measurements where

  15. Properties of nano-structured Ni/YSZ anodes fabricated from plasma sprayable NiO/YSZ powder prepared by single step solution combustion method

    Energy Technology Data Exchange (ETDEWEB)

    Prakash, B. Shri; Balaji, N.; Kumar, S. Senthil; Aruna, S.T., E-mail: staruna194@gmail.com

    2016-12-15

    Highlights: • Preparation of plasma grade NiO/YSZ powder in single step. • Fabrication of nano-structured Ni/YSZ coating. • Conductivity of 600 S/cm at 800 °C. - Abstract: NiO/YSZ anode coatings are fabricated by atmospheric plasma spraying at different plasma powers from plasma grade NiO/YSZ powders that are prepared in a single step by solution combustion method. The process adopted is devoid of multi-steps that are generally involved in conventional spray drying or fusing and crushing methods. Density of the coating increased and porosity decreased with increase in the plasma power of deposition. An ideal nano-structured Ni/YSZ anode encompassing nano YSZ particles, nano Ni particles and nano pores is achieved on reducing the coating deposited at lower plasma powers. The coating exhibit porosities in the range of 27%, sufficient for anode functional layers. Electronic conductivity of the coatings is in the range of 600 S/cm at 800 °C.

  16. Thin film complementary metal oxide semiconductor (CMOS) device using a single-step deposition of the channel layer

    KAUST Repository

    Nayak, Pradipta K.; Caraveo-Frescas, J. A.; Wang, Zhenwei; Hedhili, Mohamed N.; Wang, Q. X.; Alshareef, Husam N.

    2014-01-01

    We report, for the first time, the use of a single step deposition of semiconductor channel layer to simultaneously achieve both n-and p-type transport in transparent oxide thin film transistors (TFTs). This effect is achieved by controlling

  17. The Effects of Multiple-Step and Single-Step Directions on Fourth and Fifth Grade Students' Grammar Assessment Performance

    Science.gov (United States)

    Mazerik, Matthew B.

    2006-01-01

    The mean scores of English Language Learners (ELL) and English Only (EO) students in 4th and 5th grade (N = 110), across the teacher-administered Grammar Skills Test, were examined for differences in participants' scores on assessments containing single-step directions and assessments containing multiple-step directions. The results indicated no…

  18. An efficient single-step scheme for manipulating quantum information of two trapped ions beyond the Lamb-Dicke limit

    International Nuclear Information System (INIS)

    Wei, L.F.; Nori, Franco

    2003-01-01

    Based on the exact conditional quantum dynamics for a two-ion system, we propose an efficient single-step scheme for coherently manipulating quantum information of two trapped cold ions by using a pair of synchronous laser pulses. Neither the auxiliary atomic level nor the Lamb-Dicke approximation are needed

  19. Microwave pyrolysis using self-generated pyrolysis gas as activating agent: An innovative single-step approach to convert waste palm shell into activated carbon

    Science.gov (United States)

    Yek, Peter Nai Yuh; Keey Liew, Rock; Shahril Osman, Mohammad; Chung Wong, Chee; Lam, Su Shiung

    2017-11-01

    Waste palm shell (WPS) is a biomass residue largely available from palm oil industries. An innovative microwave pyrolysis method was developed to produce biochar from WPS while the pyrolysis gas generated as another product is simultaneously used as activating agent to transform the biochar into waste palm shell activated carbon (WPSAC), thus allowing carbonization and activation to be performed simultaneously in a single-step approach. The pyrolysis method was investigated over a range of process temperature and feedstock amount with emphasis on the yield and composition of the WPSAC obtained. The WPSAC was tested as dye adsorbent in removing methylene blue. This pyrolysis approach provided a fast heating rate (37.5°/min) and short process time (20 min) in transforming WPS into WPSAC, recording a product yield of 40 wt%. The WPSAC was detected with high BET surface area (≥ 1200 m2/g), low ash content (< 5 wt%), and high pore volume (≥ 0.54 cm3/g), thus recording high adsorption efficiency of 440 mg of dye/g. The desirable process features (fast heating rate, short process time) and the recovery of WPSAC suggest the exceptional promise of the single-step microwave pyrolysis approach to produce high-grade WPSAC from WPS.

  20. Thermodynamic approach and comparison of two-step and single step DME (dimethyl ether) syntheses with carbon dioxide utilization

    International Nuclear Information System (INIS)

    Chen, Wei-Hsin; Hsu, Chih-Liang; Wang, Xiao-Dong

    2016-01-01

    DME (Dimethyl ether) synthesis from syngas with CO_2 utilization through two-step and single step processes is analyzed thermodynamically. The influences of reaction temperature, H_2/CO molar ratio, and CO_2/CO molar ratio on CO and CO_2 conversions, DME selectivity and yield, and thermal behavior are evaluated. Particular attention is paid to the comparison of the performance of DME synthesis between the two different methods. In the two-step method, the addition of CO_2 suppresses the CO conversion during methanol synthesis. An increase in CO_2/CO ratio decreases the CO_2 conversion (negative effect), but increases the total consumption amount of CO_2 (positive effect). At a given reaction temperature with H_2/CO = 4, the maximum DME yield develops at CO_2/CO = 1. In the single step method, over 98% of CO can be converted and the DME yield can be as high as 0.52 mol (mol CO)"−"1 at CO_2/CO = 2. The comparison of the single step and two-step processes indicates that the maximum CO conversion, DME selectivity, and DME yield in the former are higher than those in the latter, whereas an opposite result in the maximum CO_2 conversion is observed. These results reveal that the single step process has lower thermodynamic limitation and is a better option for DME synthesis. From CO_2 utilization point of view, the operation with low temperature, high H_2/CO ratio, and low CO_2/CO ratio results in higher CO_2 conversion, irrespective of two-step or single step DME synthesis. - Highlights: • DME (Dimethyl ether) synthesis with CO_2 utilization is analyzed thermodynamically. • Single step and two-step DME syntheses are studied and compared with each other. • CO_2 addition suppresses CO conversion in MeOH synthesis but increases MeOH yield. • The performance of the single step DME synthesis is better than that of the two-step one. • Increase CO_2/CO ratio decreases CO_2 conversion but increases CO_2 consumption amount.

  1. Single-step brazing process for mono-block joints and mechanical testing

    International Nuclear Information System (INIS)

    Casalegno, V.; Ferraris, M.; Salvo, M.; Rizzo, S.; Merola, M.

    2007-01-01

    Full text of publication follows: Plasma facing components act as actively cooled thermal shields to sustain thermal and particle loads during normal and transient operations in ITER (International Thermonuclear Experimental Reactor). The plasma-facing layer is referred to as 'armour', which is made of either carbon fibre reinforced carbon composite (CFC) or tungsten (W). CFC is the reference design solution for the lower part of the vertical target of the ITER divertor. The armour is joined onto an actively cooled substrate, the heat sink, made of precipitation hardened copper alloy CuCrZr through a thin pure copper interlayer to decrease, by plastic deformation, the joint interface stresses; in fact, the CFC to Cu joint is affected by the CTE mismatch between the ceramic and metallic material. A new method of joining CFC to copper and CFC/Cu to CuCrZr alloy was effectively developed for the flat-type configuration; the feasibility of this process also for mono-block geometry and the development of a procedure for testing mono-block-type mock-ups is described in this work. The mono-block configuration consists of copper alloy pipe shielded by CFC blocks. It is worth noting that in mono-block configuration, the large thermal expansion mismatch between CFC and copper alloy is more significant than for flat-tile configuration, due to curved interfaces. The joining technique foresees a single-step brazing process: the brazing of the three materials (CFC-Cu-CuCrZr) can be performed in a single heat treatment using the same Cu/Ge based braze. The composite surface was modified by solid state reaction with chromium with the purpose of increasing the wettability of CFC by the brazing alloy. The CFC substrate reacts with Cr which, forming a carbide layer, allows a large reduction of the contact angle; then, the brazing of CFC to pure copper and pure copper to CuCrZr by the same treatment is feasible. This process allows to obtain good joints using a non-active brazing

  2. Single-step brazing process for mono-block joints and mechanical testing

    Energy Technology Data Exchange (ETDEWEB)

    Casalegno, V.; Ferraris, M.; Salvo, M.; Rizzo, S. [Politecnico di Torino, Materials Science and Chemical Engineering Dept., Torino (Italy); Merola, M. [ITER International Team, llER Joint Work Site, Cadarache, 13 - St Paul Lez Durance (France)

    2007-07-01

    Full text of publication follows: Plasma facing components act as actively cooled thermal shields to sustain thermal and particle loads during normal and transient operations in ITER (International Thermonuclear Experimental Reactor). The plasma-facing layer is referred to as 'armour', which is made of either carbon fibre reinforced carbon composite (CFC) or tungsten (W). CFC is the reference design solution for the lower part of the vertical target of the ITER divertor. The armour is joined onto an actively cooled substrate, the heat sink, made of precipitation hardened copper alloy CuCrZr through a thin pure copper interlayer to decrease, by plastic deformation, the joint interface stresses; in fact, the CFC to Cu joint is affected by the CTE mismatch between the ceramic and metallic material. A new method of joining CFC to copper and CFC/Cu to CuCrZr alloy was effectively developed for the flat-type configuration; the feasibility of this process also for mono-block geometry and the development of a procedure for testing mono-block-type mock-ups is described in this work. The mono-block configuration consists of copper alloy pipe shielded by CFC blocks. It is worth noting that in mono-block configuration, the large thermal expansion mismatch between CFC and copper alloy is more significant than for flat-tile configuration, due to curved interfaces. The joining technique foresees a single-step brazing process: the brazing of the three materials (CFC-Cu-CuCrZr) can be performed in a single heat treatment using the same Cu/Ge based braze. The composite surface was modified by solid state reaction with chromium with the purpose of increasing the wettability of CFC by the brazing alloy. The CFC substrate reacts with Cr which, forming a carbide layer, allows a large reduction of the contact angle; then, the brazing of CFC to pure copper and pure copper to CuCrZr by the same treatment is feasible. This process allows to obtain good joints using a non

  3. Determination of oil reservoir radiotracer (S14CN−) in a single step using a plastic scintillator extractive resin

    International Nuclear Information System (INIS)

    Bagán, H.; Tarancón, A.; Stavsetra, L.; Rauret, G.; García, J.F.

    2012-01-01

    Highlights: ► A new procedure for S 14 CN − radiotracer determination using PS resin was established. ► The minimum detectable activity for a 100 mL sample is 0.08 Bq L −1 . ► The minimum quantifiable activity for a 100 mL sample is 0.31 Bq L −1 . ► PS resin is capable to quantify S 14 CN − radiotracer samples with errors lower than 5%. ► PS resin is also capable to quantify complex matrices obtained from oil reservoirs. - Abstract: The analysis of radiotracers is important in the study of oil reservoir dynamics. One of the most widely used radiotracer is S 14 CN − . Prior to activity measurements by Liquid Scintillation (LS), routine determinations require the pretreatment steps of purification and concentration of the samples using anion exchange columns. The final elution media produces samples with high salt concentration that may lead to problems with phase separation during the LS measurement. Plastic Scintillation (PS) is an alternative technique that provides a solid surface that can be used as a platform for the immobilisation of selective extractants to obtain a PS resin. The proposed procedure unifies chemical separation and sample measurement preparation in a single step, serving to reduce the number of reagents needed and manpower required for the analysis while also avoiding mixed waste production by LS. The objective of this study is to develop a PS resin for the determination of 14 C-labelled thiocyanate radiotracer in water samples. For this purpose, the immobilisation procedure was optimised, including optimisation of the proportion of PS microspheres:extractant and the use of a control blank to monitor the PS resin immobilisation process. The breakthrough volume was studied and the detection and quantification limits for 100 mL of sample were determined to be 0.08 Bq L −1 and 0.31 Bq L −1 , respectively. The established procedure was applied to active samples from oil reservoirs and errors lower than 5% in the sample

  4. Kinase detection with gallium nitride based high electron mobility transistors.

    Science.gov (United States)

    Makowski, Matthew S; Bryan, Isaac; Sitar, Zlatko; Arellano, Consuelo; Xie, Jinqiao; Collazo, Ramon; Ivanisevic, Albena

    2013-07-01

    A label-free kinase detection system was fabricated by the adsorption of gold nanoparticles functionalized with kinase inhibitor onto AlGaN/GaN high electron mobility transistors (HEMTs). The HEMTs were operated near threshold voltage due to the greatest sensitivity in this operational region. The Au NP/HEMT biosensor system electrically detected 1 pM SRC kinase in ionic solutions. These results are pertinent to drug development applications associated with kinase sensing.

  5. Genetic evaluation using single-step genomic best linear unbiased predictor in American Angus.

    Science.gov (United States)

    Lourenco, D A L; Tsuruta, S; Fragomeni, B O; Masuda, Y; Aguilar, I; Legarra, A; Bertrand, J K; Amen, T S; Wang, L; Moser, D W; Misztal, I

    2015-06-01

    Predictive ability of genomic EBV when using single-step genomic BLUP (ssGBLUP) in Angus cattle was investigated. Over 6 million records were available on birth weight (BiW) and weaning weight (WW), almost 3.4 million on postweaning gain (PWG), and over 1.3 million on calving ease (CE). Genomic information was available on, at most, 51,883 animals, which included high and low EBV accuracy animals. Traditional EBV was computed by BLUP and genomic EBV by ssGBLUP and indirect prediction based on SNP effects was derived from ssGBLUP; SNP effects were calculated based on the following reference populations: ref_2k (contains top bulls and top cows that had an EBV accuracy for BiW ≥0.85), ref_8k (contains all parents that were genotyped), and ref_33k (contains all genotyped animals born up to 2012). Indirect prediction was obtained as direct genomic value (DGV) or as an index of DGV and parent average (PA). Additionally, runs with ssGBLUP used the inverse of the genomic relationship matrix calculated by an algorithm for proven and young animals (APY) that uses recursions on a small subset of reference animals. An extra reference subset included 3,872 genotyped parents of genotyped animals (ref_4k). Cross-validation was used to assess predictive ability on a validation population of 18,721 animals born in 2013. Computations for growth traits used multiple-trait linear model and, for CE, a bivariate CE-BiW threshold-linear model. With BLUP, predictivities were 0.29, 0.34, 0.23, and 0.12 for BiW, WW, PWG, and CE, respectively. With ssGBLUP and ref_2k, predictivities were 0.34, 0.35, 0.27, and 0.13 for BiW, WW, PWG, and CE, respectively, and with ssGBLUP and ref_33k, predictivities were 0.39, 0.38, 0.29, and 0.13 for BiW, WW, PWG, and CE, respectively. Low predictivity for CE was due to low incidence rate of difficult calving. Indirect predictions with ref_33k were as accurate as with full ssGBLUP. Using the APY and recursions on ref_4k gave 88% gains of full ssGBLUP and

  6. Comparison on genomic predictions using GBLUP models and two single-step blending methods with different relationship matrices in the Nordic Holstein population

    DEFF Research Database (Denmark)

    Gao, Hongding; Christensen, Ole Fredslund; Madsen, Per

    2012-01-01

    Background A single-step blending approach allows genomic prediction using information of genotyped and non-genotyped animals simultaneously. However, the combined relationship matrix in a single-step method may need to be adjusted because marker-based and pedigree-based relationship matrices may...... not be on the same scale. The same may apply when a GBLUP model includes both genomic breeding values and residual polygenic effects. The objective of this study was to compare single-step blending methods and GBLUP methods with and without adjustment of the genomic relationship matrix for genomic prediction of 16......) a simple GBLUP method, 2) a GBLUP method with a polygenic effect, 3) an adjusted GBLUP method with a polygenic effect, 4) a single-step blending method, and 5) an adjusted single-step blending method. In the adjusted GBLUP and single-step methods, the genomic relationship matrix was adjusted...

  7. Superhydrophobic polytetrafluoroethylene thin films with hierarchical roughness deposited using a single step vapor phase technique

    International Nuclear Information System (INIS)

    Gupta, Sushant; Arjunan, Arul Chakkaravarthi; Deshpande, Sameer; Seal, Sudipta; Singh, Deepika; Singh, Rajiv K.

    2009-01-01

    Superhydrophobic polytetrafluoroethylene films with hierarchical surface roughness were deposited using pulse electron deposition technique. We were able to modulate roughness of the deposited films by controlling the beam energy and hence the electron penetration depth. The films deposited at higher beam energy showed contact angle as high as 166 o . The scanning electron and atomic force microscope studies revealed clustered growth and two level sub-micron asperities on films deposited at higher energies. Such dual-scale hierarchical roughness and heterogeneities at the water-surface interface was attributed to the observed contact angle and thus its superhydrophobic nature.

  8. Superhydrophobic polytetrafluoroethylene thin films with hierarchical roughness deposited using a single step vapor phase technique

    Energy Technology Data Exchange (ETDEWEB)

    Gupta, Sushant, E-mail: sushant3@ufl.ed [Department of Materials Science and Engineering, University of Florida, Gainesville, FL 32611 (United States); Arjunan, Arul Chakkaravarthi [Sinmat Incorporated, 2153 SE Hawthorne Road, 129, Gainesville, Florida 32641 (United States); Deshpande, Sameer; Seal, Sudipta [Advanced Material Processing and Analysis Center, University of Central Florida, Orlando, Florida 32816 (United States); Singh, Deepika [Sinmat Incorporated, 2153 SE Hawthorne Road, 129, Gainesville, Florida 32641 (United States); Singh, Rajiv K. [Department of Materials Science and Engineering, University of Florida, Gainesville, FL 32611 (United States)

    2009-06-30

    Superhydrophobic polytetrafluoroethylene films with hierarchical surface roughness were deposited using pulse electron deposition technique. We were able to modulate roughness of the deposited films by controlling the beam energy and hence the electron penetration depth. The films deposited at higher beam energy showed contact angle as high as 166{sup o}. The scanning electron and atomic force microscope studies revealed clustered growth and two level sub-micron asperities on films deposited at higher energies. Such dual-scale hierarchical roughness and heterogeneities at the water-surface interface was attributed to the observed contact angle and thus its superhydrophobic nature.

  9. Hydrocarbon isotope detection by elastic peak electron spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Kostanovskiy, I.A., E-mail: kostanovskiyia@gmail.com [National Research University MPEI, Krasnokazarmennaya 14, 111250 Moscow (Russian Federation); Afanas’ev, V.P. [National Research University MPEI, Krasnokazarmennaya 14, 111250 Moscow (Russian Federation); Naujoks, D. [Max-Planck-Institut für Plasmaphysik, Teilinstitut Greifswald, Wendelsteinstraße 1, D-17491 Greifswald (Germany); Mayer, M. [Max-Planck-Institut für Plasmaphysik, D-85748 Garching (Germany)

    2015-07-15

    Highlights: • PCVD hydrocarbon coatings containing protium or deuterium are analyzed via NRA, ERD, XPS and EPES. • EPES analysis with modern electron energy analyzer SPECS Phoibos 225 shows a clear signal from the hydrogen isotopes. • Different primary energies and scattering angles help to quantify isotope content from EPES spectra. - Abstract: Experimental results on the hydrocarbon isotope analysis by elastic peak electron spectroscopy are presented. Amorphous hydrocarbon samples (a-C:H, a-C:D) are prepared by PCVD and analyzed by nuclear reaction analysis (NRA), elastic recoil detection analysis (ERD), X-ray photoelectron spectroscopy (XPS) and elastic peak electron spectroscopy (EPES). Electron energy spectra show a clear signal from the hydrogen isotopes deuterium and protium. Different incident energies and scattering geometries help to resolve plasmon and elastic energy losses.

  10. Hydrocarbon isotope detection by elastic peak electron spectroscopy

    International Nuclear Information System (INIS)

    Kostanovskiy, I.A.; Afanas’ev, V.P.; Naujoks, D.; Mayer, M.

    2015-01-01

    Highlights: • PCVD hydrocarbon coatings containing protium or deuterium are analyzed via NRA, ERD, XPS and EPES. • EPES analysis with modern electron energy analyzer SPECS Phoibos 225 shows a clear signal from the hydrogen isotopes. • Different primary energies and scattering angles help to quantify isotope content from EPES spectra. - Abstract: Experimental results on the hydrocarbon isotope analysis by elastic peak electron spectroscopy are presented. Amorphous hydrocarbon samples (a-C:H, a-C:D) are prepared by PCVD and analyzed by nuclear reaction analysis (NRA), elastic recoil detection analysis (ERD), X-ray photoelectron spectroscopy (XPS) and elastic peak electron spectroscopy (EPES). Electron energy spectra show a clear signal from the hydrogen isotopes deuterium and protium. Different incident energies and scattering geometries help to resolve plasmon and elastic energy losses

  11. Single step hydrothermal based synthesis of M(II)Sb2O6 (M = Cd ...

    Indian Academy of Sciences (India)

    characterized by powder X-ray diffraction, scanning electron microscopy, energy dispersive .... SEM images and EDAX analysis of (a) and (b) CdSb2O6 and (c) and (d) ZnSb2O6. ... The parent compound, ilmenite (NaSbO3) could degrade MB.

  12. Microwave Plasma Based Single-Step Method for Generation of Carbon Nanostructures

    Science.gov (United States)

    2013-07-01

    Técnico, Technical University of Lisbon, Portugal 2 Mechanical and Aerospace Engeneering , Naval Postgraduate School, Monterey, CA 93943, U.S.A...applications include electronic devices, transparent conductive films, mechanical devices, chemical sensors, spintronic devices. Moreover, it shows enormous...potential as a storage material for energy applications. Graphene of highest quality can be obtained by mechanically exfoliating highly oriented

  13. Comparative analysis of single-step and two-step biodiesel production using supercritical methanol on laboratory-scale

    International Nuclear Information System (INIS)

    Micic, Radoslav D.; Tomić, Milan D.; Kiss, Ferenc E.; Martinovic, Ferenc L.; Simikić, Mirko Ð.; Molnar, Tibor T.

    2016-01-01

    Highlights: • Single-step supercritical transesterification compared to the two-step process. • Two-step process: oil hydrolysis and subsequent supercritical methyl esterification. • Experiments were conducted in a laboratory-scale batch reactor. • Higher biodiesel yields in two-step process at milder reaction conditions. • Two-step process has potential to be cost-competitive with the single-step process. - Abstract: Single-step supercritical transesterification and two-step biodiesel production process consisting of oil hydrolysis and subsequent supercritical methyl esterification were studied and compared. For this purpose, comparative experiments were conducted in a laboratory-scale batch reactor and optimal reaction conditions (temperature, pressure, molar ratio and time) were determined. Results indicate that in comparison to a single-step transesterification, methyl esterification (second step of the two-step process) produces higher biodiesel yields (95 wt% vs. 91 wt%) at lower temperatures (270 °C vs. 350 °C), pressures (8 MPa vs. 12 MPa) and methanol to oil molar ratios (1:20 vs. 1:42). This can be explained by the fact that the reaction system consisting of free fatty acid (FFA) and methanol achieves supercritical condition at milder reaction conditions. Furthermore, the dissolved FFA increases the acidity of supercritical methanol and acts as an acid catalyst that increases the reaction rate. There is a direct correlation between FFA content of the product obtained in hydrolysis and biodiesel yields in methyl esterification. Therefore, the reaction parameters of hydrolysis were optimized to yield the highest FFA content at 12 MPa, 250 °C and 1:20 oil to water molar ratio. Results of direct material and energy costs comparison suggest that the process based on the two-step reaction has the potential to be cost-competitive with the process based on single-step supercritical transesterification. Higher biodiesel yields, similar or lower energy

  14. Proposal to detect an emission of unusual super-high energy electrons in electron storage rings

    Directory of Open Access Journals (Sweden)

    Da-peng Qian

    2014-01-01

    Full Text Available According to an extended Lorentz–Einstein mass formula taken into the uncertainty principle, it is predicted that the electron beams passing accelerating electric field should with a small probability generate abnormal super-high energy electrons which are much higher than the beam energy. Author’s preliminary experiment result at electron storage ring has hinted these signs, so suggests to more strictly detect this unusual phenomenon, and thus to test the extended mass formula as well as a more perfect special relativity.

  15. Heart rate detection from an electronic weighing scale

    International Nuclear Information System (INIS)

    González-Landaeta, R; Casas, O; Pallàs-Areny, R

    2008-01-01

    We propose a novel technique for beat-to-beat heart rate detection based on the ballistocardiographic (BCG) force signal from a subject standing on a common electronic weighing scale. The detection relies on sensing force variations related to the blood acceleration in the aorta, works even if wearing footwear and does not require any sensors attached to the body because it uses the load cells in the scale. We have devised an approach to estimate the sensitivity and frequency response of three commercial weighing scales to assess their capability to detect the BCG force signal. Static sensitivities ranged from 490 nV V −1 N −1 to 1670 nV V −1 N −1 . The frequency response depended on the subject's mass but it was broad enough for heart rate estimation. We have designed an electronic pulse detection system based on off-the-shelf integrated circuits to sense heart-beat-related force variations of about 0.24 N. The signal-to-noise ratio of the main peaks of the force signal detected was higher than 30 dB. A Bland–Altman plot was used to compare the RR time intervals estimated from the ECG and BCG force signals for 17 volunteers. The error was ±21 ms, which makes the proposed technique suitable for short-term monitoring of the heart rate

  16. Structural comparison of anodic nanoporous-titania fabricated from single-step and three-step of anodization using two paralleled-electrodes anodizing cell

    Directory of Open Access Journals (Sweden)

    Mallika Thabuot

    2016-02-01

    Full Text Available Anodization of Ti sheet in the ethylene glycol electrolyte containing 0.38wt% NH4F with the addition of 1.79wt% H2O at room temperature was studied. Applied potential of 10-60 V and anodizing time of 1-3 h were conducted by single-step and three-step of anodization within the two paralleled-electrodes anodizing cell. Their structural and textural properties were investigated by X-ray diffraction (XRD and scanning electron microscopy (SEM. After annealing at 600°C in the air furnace for 3 h, TiO2-nanotubes was transformed to the higher proportion of anatase crystal phase. Also crystallization of anatase phase was enhanced as the duration of anodization as the final step increased. By using single-step of anodization, pore texture of oxide film was started to reveal at the applied potential of 30 V. Better orderly arrangement of the TiO2-nanotubes array with larger pore size was obtained with the increase of applied potential. The applied potential of 60 V was selected for the three-step of anodization with anodizing time of 1-3 h. Results showed that the well-smooth surface coverage with higher density of porous-TiO2 was achieved using prolonging time at the first and second step, however, discontinuity tube in length was produced instead of the long-vertical tube. Layer thickness of anodic oxide film depended on the anodizing time at the last step of anodization. More well arrangement of nanostructured-TiO2 was produced using three-step of anodization under 60 V with 3 h for each step.

  17. Single Step In Situ Synthesis and Optical Properties of Polyaniline/ZnO Nanocomposites

    Directory of Open Access Journals (Sweden)

    Deepali Sharma

    2014-01-01

    Full Text Available Polyaniline/ZnO nanocomposites were prepared by in situ oxidative polymerization of aniline monomer in the presence of different weight percentages of ZnO nanostructures. The steric stabilizer added to prevent the agglomeration of nanostructures in the polymer matrix was found to affect the final properties of the nanocomposite. ZnO nanostructures of various morphologies and sizes were prepared in the absence and presence of sodium lauryl sulphate (SLS surfactant under different reaction conditions like in the presence of microwave radiation (microwave oven, under pressure (autoclave, under vacuum (vacuum oven, and at room temperature (ambient condition. The conductivity of these synthesized nanocomposites was evaluated using two-probe method and the effect of concentration of ZnO nanostructures on conductivity was observed. X-ray diffraction (XRD, scanning electron microscopy (SEM, transmission electron microscopy (TEM, Fourier transform infrared spectroscopy (FTIR, and UV-visible (UV-VIS spectroscopy techniques were used to characterize nanocomposites. The optical energy band gap of the nanocomposites was calculated from absorption spectra and ranged between 1.5 and 3.21 eV. The reported values depicted the blue shift in nanocomposites as compared to the band gap energies of synthesized ZnO nanostructures. The present work focuses on the one-step synthesis and potential use of PANI/ZnO nanocomposite in molecular electronics as well as in optical devices.

  18. Using Electronic Noses to Detect Tumors During Neurosurgery

    Science.gov (United States)

    Homer, Margie L.; Ryan, Margaret A.; Lara, Liana M.; Kateb, Babak; Chen, Mike

    2008-01-01

    It has been proposed to develop special-purpose electronic noses and algorithms for processing the digitized outputs of the electronic noses for determining whether tissue exposed during neurosurgery is cancerous. At present, visual inspection by a surgeon is the only available intraoperative technique for detecting cancerous tissue. Implementation of the proposal would help to satisfy a desire, expressed by some neurosurgeons, for an intraoperative technique for determining whether all of a brain tumor has been removed. The electronic-nose technique could complement multimodal imaging techniques, which have also been proposed as means of detecting cancerous tissue. There are also other potential applications of the electronic-nose technique in general diagnosis of abnormal tissue. In preliminary experiments performed to assess the viability of the proposal, the problem of distinguishing between different types of cultured cells was substituted for the problem of distinguishing between normal and abnormal specimens of the same type of tissue. The figure presents data from one experiment, illustrating differences between patterns that could be used to distinguish between two types of cultured cancer cells. Further development can be expected to include studies directed toward answering questions concerning not only the possibility of distinguishing among various types of normal and abnormal tissue but also distinguishing between tissues of interest and other odorous substances that may be present in medical settings.

  19. The effects of strength and power training on single-step balance recovery in older adults: a preliminary study.

    Science.gov (United States)

    Pamukoff, Derek N; Haakonssen, Eric C; Zaccaria, Joseph A; Madigan, Michael L; Miller, Michael E; Marsh, Anthony P

    2014-01-01

    Improving muscle strength and power may mitigate the effects of sarcopenia, but it is unknown if this improves an older adult's ability to recover from a large postural perturbation. Forward tripping is prevalent in older adults and lateral falls are important due to risk of hip fracture. We used a forward and a lateral single-step balance recovery task to examine the effects of strength training (ST) or power (PT) training on single-step balance recovery in older adults. Twenty older adults (70.8±4.4 years, eleven male) were randomly assigned to either a 6-week (three times/week) lower extremity ST or PT intervention. Maximum forward (FLean(max)) and lateral (LLean(max)) lean angle and strength and power in knee extension and leg press were assessed at baseline and follow-up. Fifteen participants completed the study (ST =7, PT =8). Least squares means (95% CI) for ΔFLean(max) (ST: +4.1° [0.7, 7.5]; PT: +0.6° [-2.5, 3.8]) and ΔLLean(max) (ST: +2.2° [0.4, 4.1]; PT: +2.6° [0.9, 4.4]) indicated no differences between groups following training. In exploratory post hoc analyses collapsed by group, ΔFLean(max) was +2.4° (0.1, 4.7) and ΔLLean(max) was +2.4° (1.2, 3.6). These improvements on the balance recovery tasks ranged from ~15%-30%. The results of this preliminary study suggest that resistance training may improve balance recovery performance, and that, in this small sample, PT did not lead to larger improvements in single-step balance recovery compared to ST.

  20. Single-step generation of metal-plasma polymer multicore@shell nanoparticles from the gas phase.

    Science.gov (United States)

    Solař, Pavel; Polonskyi, Oleksandr; Olbricht, Ansgar; Hinz, Alexander; Shelemin, Artem; Kylián, Ondřej; Choukourov, Andrei; Faupel, Franz; Biederman, Hynek

    2017-08-17

    Nanoparticles composed of multiple silver cores and a plasma polymer shell (multicore@shell) were prepared in a single step with a gas aggregation cluster source operating with Ar/hexamethyldisiloxane mixtures and optionally oxygen. The size distribution of the metal inclusions as well as the chemical composition and the thickness of the shells were found to be controlled by the composition of the working gas mixture. Shell matrices ranging from organosilicon plasma polymer to nearly stoichiometric SiO 2 were obtained. The method allows facile fabrication of multicore@shell nanoparticles with tailored functional properties, as demonstrated here with the optical response.

  1. Single-Step Transepithelial PRK vs Alcohol-Assisted PRK in Myopia and Compound Myopic Astigmatism Correction

    OpenAIRE

    Kaluzny, Bartlomiej J.; Cieslinska, Iwona; Mosquera, Samuel A.; Verma, Shwetabh

    2016-01-01

    Abstract Transepithelial photorefractive keratectomy (tPRK), where both the epithelium and stroma are removed in a single-step, is a relatively new procedure of laser refractive error correction. This study compares the 3-month results of myopia and compound myopic astigmatism correction by tPRK or conventional alcohol-assisted PRK (aaPRK). This prospective, nonrandomized, case?control study recruited 148 consecutive patients; 93 underwent tPRK (173 eyes) and 55 aaPRK (103 eyes). Refractive r...

  2. Thin film complementary metal oxide semiconductor (CMOS) device using a single-step deposition of the channel layer

    KAUST Repository

    Nayak, Pradipta K.

    2014-04-14

    We report, for the first time, the use of a single step deposition of semiconductor channel layer to simultaneously achieve both n-and p-type transport in transparent oxide thin film transistors (TFTs). This effect is achieved by controlling the concentration of hydroxyl groups (OH-groups) in the underlying gate dielectrics. The semiconducting tin oxide layer was deposited at room temperature, and the maximum device fabrication temperature was 350C. Both n and p-type TFTs showed fairly comparable performance. A functional CMOS inverter was fabricated using this novel scheme, indicating the potential use of our approach for various practical applications.

  3. Contact detection for nanomanipulation in a scanning electron microscope

    International Nuclear Information System (INIS)

    Ru, Changhai; To, Steve

    2012-01-01

    Nanomanipulation systems require accurate knowledge of the end-effector position in all three spatial coordinates, XYZ, for reliable manipulation of nanostructures. Although the images acquired by a scanning electron microscope (SEM) provide high resolution XY information, the lack of depth information in the Z-direction makes 3D nanomanipulation time-consuming. Existing approaches for contact detection of end-effectors inside SEM typically utilize fragile touch sensors that are difficult to integrate into a nanomanipulation system. This paper presents a method for determining the contact between an end-effector and a target surface during nanomanipulation inside SEM, purely based on the processing of SEM images. A depth-from-focus method is used in the fast approach of the end-effector to the substrate, followed by fine contact detection. Experimental results demonstrate that the contact detection approach is capable of achieving an accuracy of 21.5 nm at 50,000× magnification while inducing little end-effector damage. -- Highlights: ► We presents a simple method for obtaining the depth information in SEM-based nanomanipulation. ► Detecting contact between an end-effector and a target surface using SEM as a vision sensor. ► Additional touch/force sensors or specialized hardware need not be added. ► Achieved high repeatability and accuracy. ► Complete automatic contact detection within typically 60 s.

  4. Contact detection for nanomanipulation in a scanning electron microscope

    Energy Technology Data Exchange (ETDEWEB)

    Ru, Changhai, E-mail: rchhai@gmail.com [Automation College, Harbin Engineering University, Harbin 150001 (China); Robotics and Microsystems Center, Soochow University, Jiangsu 215021 (China); To, Steve, E-mail: Steve.to@utoronto.ca [Department of Mechanical and Industry Engineering, University of Toronto, Ontario, Canada M5S3G8 (Canada)

    2012-07-15

    Nanomanipulation systems require accurate knowledge of the end-effector position in all three spatial coordinates, XYZ, for reliable manipulation of nanostructures. Although the images acquired by a scanning electron microscope (SEM) provide high resolution XY information, the lack of depth information in the Z-direction makes 3D nanomanipulation time-consuming. Existing approaches for contact detection of end-effectors inside SEM typically utilize fragile touch sensors that are difficult to integrate into a nanomanipulation system. This paper presents a method for determining the contact between an end-effector and a target surface during nanomanipulation inside SEM, purely based on the processing of SEM images. A depth-from-focus method is used in the fast approach of the end-effector to the substrate, followed by fine contact detection. Experimental results demonstrate that the contact detection approach is capable of achieving an accuracy of 21.5 nm at 50,000 Multiplication-Sign magnification while inducing little end-effector damage. -- Highlights: Black-Right-Pointing-Pointer We presents a simple method for obtaining the depth information in SEM-based nanomanipulation. Black-Right-Pointing-Pointer Detecting contact between an end-effector and a target surface using SEM as a vision sensor. Black-Right-Pointing-Pointer Additional touch/force sensors or specialized hardware need not be added. Black-Right-Pointing-Pointer Achieved high repeatability and accuracy. Black-Right-Pointing-Pointer Complete automatic contact detection within typically 60 s.

  5. Data Fusion of Electronic Nose and Electronic Tongue for Detection of Mixed Edible-Oil

    OpenAIRE

    Men, Hong; Chen, Donglin; Zhang, Xiaoting; Liu, Jingjing; Ning, Ke

    2014-01-01

    For the problem of the waste of the edible-oil in the food processing, on the premise of food security, they often need to add new edible-oil to the old frying oil which had been used in food processing to control the cost of the production. Due to the fact that the different additive proportion of the oil has different material and different volatile gases, we use fusion technology based on the electronic nose and electronic tongue to detect the blending ratio of the old frying oil and the n...

  6. Effect of increased exposure times on amount of residual monomer released from single-step self-etch adhesives.

    Science.gov (United States)

    Altunsoy, Mustafa; Botsali, Murat Selim; Tosun, Gonca; Yasar, Ahmet

    2015-10-16

    The aim of this study was to evaluate the effect of increased exposure times on the amount of residual Bis-GMA, TEGDMA, HEMA and UDMA released from single-step self-etch adhesive systems. Two adhesive systems were used. The adhesives were applied to bovine dentin surface according to the manufacturer's instructions and were polymerized using an LED curing unit for 10, 20 and 40 seconds (n = 5). After polymerization, the specimens were stored in 75% ethanol-water solution (6 mL). Residual monomers (Bis-GMA, TEGDMA, UDMA and HEMA) that were eluted from the adhesives (after 10 minutes, 1 hour, 1 day, 7 days and 30 days) were analyzed by high-performance liquid chromatography (HPLC). The data were analyzed using 1-way analysis of variance and Tukey HSD tests. Among the time periods, the highest amount of released residual monomers from adhesives was observed in the 10th minute. There were statistically significant differences regarding released Bis-GMA, UDMA, HEMA and TEGDMA between the adhesive systems (p<0.05). There were no significant differences among the 10, 20 and 40 second polymerization times according to their effect on residual monomer release from adhesives (p>0.05). Increasing the polymerization time did not have an effect on residual monomer release from single-step self-etch adhesives.

  7. Rudimentary simple, single step fabrication of nano-flakes like AgCd alloy electro-catalyst for oxygen reduction reaction in alkaline fuel cell

    International Nuclear Information System (INIS)

    Bhandary, Nimai; Basu, Suddhasatwa; Ingole, Pravin P.

    2016-01-01

    In this work, for the first time, we report rudimentary simple, single step fabrication of an electro-catalyst based on AgCd alloy nanoparticles with flakes like geometry which shows highly efficient activity towards oxygen reduction reaction (ORR). A simple potentiostatic deposition method has been employed for co-depositing AgCd alloy nanostructures with flakes like shapes along with dendrites on the surface of carbon fibre paper. The chemico-physical properties of the catalyst are investigated by X-ray diffraction (XRD), scanning electron microscopy (SEM), X-ray photoelectron spectroscopy (XPS) and energy dispersive X-ray spectroscopy (EDXS). Electro-catalytic activity of AgCd alloy based electro-catalyst towards ORR is studied in alkaline medium by cyclic voltammetry and rotating ring disk electrode (RRDE) technique. Electrochemical in-situ FTIR measurements are also performed to identify the species generated during ORR process. Based on the results from electro-catalysis experiment, it is concluded that nano-alloyed AgCd electrodeposited on carbon paper shows excellent activity for ORR, following four electron pathways with H_2O_2 yield less than 15%. The combination of low cost of Ag and Cd, fast and facile method of its fabrication and higher activity towards ORR makes the AgCd electro-catalyst an attractive catalyst of choice for alkaline fuel cell.

  8. Extending electro-optic detection to ultrashort electron beams

    Directory of Open Access Journals (Sweden)

    M. H. Helle

    2012-05-01

    Full Text Available We propose a technique to extend noninvasive electro-optic detection of relativistic electron beams to bunch lengths of ≃10  fs. This is made possible by detecting the frequency mixing that occurs between the optical probe and the space charge fields of the beam, while simultaneously time resolving the resulting mixed frequency signal. The necessary formalism to describe this technique is developed and numerical solutions for various possible experimental conditions are made. These solutions are then compared to simulation results for consistency. Finally, the method to reconstruct the original bunch profile from the proposed diagnostic is discussed and an example showing a 15 fs test beam reconstructed to within an accuracy of 15% is given.

  9. Single step deposition of an interacting layer of a perovskite matrix with embedded quantum dots

    Science.gov (United States)

    Ngo, Thi Tuyen; Suarez, Isaac; Sanchez, Rafael S.; Martinez-Pastor, Juan P.; Mora-Sero, Ivan

    2016-07-01

    electroluminescence experiments. The radiative exciplex relaxation is centered in the near infrared region (NIR), ~1200 nm, which corresponds to lower energies than the corresponding band gap of both perovskite (PS) and QDs. Our approach allows the fabrication of multi-wavelength light emitting diodes (LEDs) based on a PS matrix with embedded QDs, which show considerably low turn-on potentials. The presence of the exciplex state of PS and QDs opens up a broad range of possibilities with important implications in both LEDs and solar cells. Electronic supplementary information (ESI) available. See DOI: 10.1039/c6nr04082a

  10. Quench detection electronics testing protocol for SST-1 magnets

    International Nuclear Information System (INIS)

    Banaudha, Moni; Varmora, Pankaj; Parghi, Bhadresh; Prasad, Upendra

    2017-01-01

    Quench Detection (QD) system consisting 204 signal channels has been successfully installed and working well during plasma experiment of SST-1 Tokamak. QD system requires testing, validation and maintenance in every SST-1 campaign for better reliability and maintainability of the system. Standalone test of each channel of the system is essential for hard-ware validation. The standard Testing Protocol follow in every campaign which validate each section of QD electronics as well as voltage tap signal cables which are routed inside the cryostat and then extended outside of the SST-1 machine up-to the magnet control room. Fiber link for Quench signal transmission to the SST-1 magnet power supply is also test and validate before every plasma campaign. Precise instrument used as a dummy source of quench signal and for manual quench generation to test the each channel and Master Quench Logic. Each signal Integrated with the magnet DAQ system, signal observed at 1Hz and 50Hz configuration to validate the logging data, compare with actual and previous test data. This paper describes the testing protocol follow in every campaign to validate functionality of QD electronics, limitation of testing, test results and overall integration of the quench detection system for SST-1 magnet. (author)

  11. Detection of electron beam irradiated crude drugs by electron spin resonance (ESR)

    International Nuclear Information System (INIS)

    Yamaoki, Rumi; Kimura, Shojiro; Aoki, Kenji; Nishimoto, Susumu

    2007-01-01

    Perillae Herba, Sennae Folium, Cinnamomi Cortex, Phellodendri Cortex, Ginseng Radix, Glycyrrhizae Radix, Paeoniae Radix, and Zingiberis Rhizoma were irradiated with electron beam (5 MeV) and organic radicals were detected by ESR measurement, before and after irradiation (10 kGy). A single line spectrum was detected at around g=2.005 in non-irradiated crude drugs, and radical concentrations were high in the leaf varieties of crude drugs. After irradiation, the signal intensity around g=2.005 increased, and a new subsignal was detected as a 3 mT shoulder of this signal. Broad, asymmetrically divided signals were also detected in irradiated root varieties of crude drugs. The free radical localized on the organic components of irradiated crude drugs tended to decrease with the water content. After irradiation, signal intensity reduced and reached a steady state after about 1 to 2 months. However, specificity of the ESR signal shape appearing after irradiation continued to be detectable for 6 months in leaf varieties and for a year in bark and root varieties of crude drugs. Consequently, it was concluded that ESR could be applied as an initial screening procedure to detect irradiated crude drugs. (author)

  12. Contact detection for nanomanipulation in a scanning electron microscope.

    Science.gov (United States)

    Ru, Changhai; To, Steve

    2012-07-01

    Nanomanipulation systems require accurate knowledge of the end-effector position in all three spatial coordinates, XYZ, for reliable manipulation of nanostructures. Although the images acquired by a scanning electron microscope (SEM) provide high resolution XY information, the lack of depth information in the Z-direction makes 3D nanomanipulation time-consuming. Existing approaches for contact detection of end-effectors inside SEM typically utilize fragile touch sensors that are difficult to integrate into a nanomanipulation system. This paper presents a method for determining the contact between an end-effector and a target surface during nanomanipulation inside SEM, purely based on the processing of SEM images. A depth-from-focus method is used in the fast approach of the end-effector to the substrate, followed by fine contact detection. Experimental results demonstrate that the contact detection approach is capable of achieving an accuracy of 21.5 nm at 50,000× magnification while inducing little end-effector damage. Copyright © 2012 Elsevier B.V. All rights reserved.

  13. Mechanical detection of electron spin resonance beyond 1 THz

    International Nuclear Information System (INIS)

    Takahashi, Hideyuki; Ohmichi, Eiji; Ohta, Hitoshi

    2015-01-01

    We report the cantilever detection of electron spin resonance (ESR) in the terahertz (THz) region. This technique mechanically detects ESR as a change in magnetic torque that acts on the cantilever. The ESR absorption of a tiny single crystal of Co Tutton salt, Co(NH 4 ) 2 (SO 4 ) 2 ⋅6H 2 O, was observed in frequencies of up to 1.1 THz using a backward travelling wave oscillator as a THz-wave source. This is the highest frequency of mechanical detection of ESR till date. The spectral resolution was evaluated with the ratio of the peak separation to the sum of the half-width at half maximum of two absorption peaks. The highest resolution value of 8.59 ± 0.53 was achieved at 685 GHz, while 2.47 ± 0.01 at 80 GHz. This technique will not only broaden the scope of ESR spectroscopy application but also lead to high-spectral-resolution ESR imaging

  14. Designed optimization of a single-step extraction of fucose-containing sulfated polysaccharides from Sargassum sp

    DEFF Research Database (Denmark)

    Ale, Marcel Tutor; Mikkelsen, Jørn Dalgaard; Meyer, Anne S.

    2012-01-01

    Fucose-containing sulfated polysaccharides can be extracted from the brown seaweed, Sargassum sp. It has been reported that fucose-rich sulfated polysaccharides from brown seaweeds exert different beneficial biological activities including anti-inflammatory, anticoagulant, and anti-viral effects....... Classical extraction of fucose-containing sulfated polysaccharides from brown seaweed species typically involves extended, multiple-step, hot acid, or CaCl2 treatments, each step lasting several hours. In this work, we systematically examined the influence of acid concentration (HCl), time, and temperature...... on the yield of fucosecontaining sulfated polysaccharides (FCSPs) in statistically designed two-step and single-step multifactorial extraction experiments. All extraction factors had significant effects on the fucose-containing sulfated polysaccharides yield, with the temperature and time exerting positive...

  15. Colloidal Quantum Dot Inks for Single-Step-Fabricated Field-Effect Transistors: The Importance of Postdeposition Ligand Removal.

    Science.gov (United States)

    Balazs, Daniel M; Rizkia, Nisrina; Fang, Hong-Hua; Dirin, Dmitry N; Momand, Jamo; Kooi, Bart J; Kovalenko, Maksym V; Loi, Maria Antonietta

    2018-02-14

    Colloidal quantum dots are a class of solution-processed semiconductors with good prospects for photovoltaic and optoelectronic applications. Removal of the surfactant, so-called ligand exchange, is a crucial step in making the solid films conductive, but performing it in solid state introduces surface defects and cracks in the films. Hence, the formation of thick, device-grade films have only been possible through layer-by-layer processing, limiting the technological interest for quantum dot solids. Solution-phase ligand exchange before the deposition allows for the direct deposition of thick, homogeneous films suitable for device applications. In this work, fabrication of field-effect transistors in a single step is reported using blade-coating, an upscalable, industrially relevant technique. Most importantly, a postdeposition washing step results in device properties comparable to the best layer-by-layer processed devices, opening the way for large-scale fabrication and further interest from the research community.

  16. Bioconversion of starch to ethanol in a single-step process by coculture of amylolytic yeasts and Saccharomyces cerevisiae 21

    Energy Technology Data Exchange (ETDEWEB)

    Verma, G.; Singh, D.; Chaudhary, K. [CCS Haryana Agricultural Univ., Hisar (India). Dept. of Biotechnology and Molecular Biology; Nigam, P. [Ulster Univ., Coleraine, Northern Ireland (United Kingdom). School of Applied Biological and Chemical Sciences

    2000-05-01

    Ethanol production by a coculture of Saccharomyces diastaticus and Saccharomyces cerevisiae 21 was 24.8 g/l using raw unhydrolysed starch in a single-step fermentation. This was 48% higher than the yield obtained with the monoculture of S. diastaticus (16.8 g/l). The maximum ethanol fermentation efficiency was achieved (93% of the theoretical value) using 60 g/l starch concentration. In another coculture fermentation with E. capsularis and S. cerevisiae 21, maximum ethanol yield was 16.0 g/l, higher than the yield with the monoculture of Endomycopsis capsularis. In batch fermentations using cocultures maximum ethanol production occurred in 48 h of fermentation at 30{sup o}C using 60 g/l starch. Fermentation efficiency was found lower in a two-step process using {alpha}-amylase and glucoamylase-treated starch. (Author)

  17. Compact Ag@Fe3O4 Core-shell Nanoparticles by Means of Single-step Thermal Decomposition Reaction

    Science.gov (United States)

    Brollo, Maria Eugênia F.; López-Ruiz, Román; Muraca, Diego; Figueroa, Santiago J. A.; Pirota, Kleber R.; Knobel, Marcelo

    2014-10-01

    A temperature pause introduced in a simple single-step thermal decomposition of iron, with the presence of silver seeds formed in the same reaction mixture, gives rise to novel compact heterostructures: brick-like Ag@Fe3O4 core-shell nanoparticles. This novel method is relatively easy to implement, and could contribute to overcome the challenge of obtaining a multifunctional heteroparticle in which a noble metal is surrounded by magnetite. Structural analyses of the samples show 4 nm silver nanoparticles wrapped within compact cubic external structures of Fe oxide, with curious rectangular shape. The magnetic properties indicate a near superparamagnetic like behavior with a weak hysteresis at room temperature. The value of the anisotropy involved makes these particles candidates to potential applications in nanomedicine.

  18. Genomic prediction by single-step genomic BLUP using cow reference population in Holstein crossbred cattle in India

    DEFF Research Database (Denmark)

    Nayee, Nilesh Kumar; Su, Guosheng; Gajjar, Swapnil

    2018-01-01

    Advantages of genomic selection in breeds with limited numbers of progeny tested bulls have been demonstrated by adding genotypes of females to the reference population (Thomasen et al., 2014). The current study was conducted to explore the feasibility of implementing genomic selection in a Holst......Advantages of genomic selection in breeds with limited numbers of progeny tested bulls have been demonstrated by adding genotypes of females to the reference population (Thomasen et al., 2014). The current study was conducted to explore the feasibility of implementing genomic selection...... in a Holstein Friesian crossbred population with cows kept under small holder conditions using test day records and single step genomic BLUP (ssGBLUP). Milk yield records from 10,797 daughters sired by 258 bulls were used Of these 2194 daughters and 109 sires were genotyped with customized genotyping chip...

  19. A direct, single-step plasma arc-vitreous ceramic process for stabilizing spent nuclear fuels, sludges, and associated wastes

    International Nuclear Information System (INIS)

    Feng, X.; Einziger, R.E.; Eschenbach, R.C.

    1997-01-01

    A single-step plasma arc-vitreous ceramic (PAVC) process is described for converting spent nuclear fuel (SNF), SNF sludges, and associated wastes into a vitreous ceramic waste form. This proposed technology is built on extensive experience of nuclear waste form development and nuclear waste treatment using the commercially available plasma arc centrifugal (PAC) system. SNF elements will be loaded directly into a PAC furnace with minimum additives and converted into vitreous ceramics with up to 90 wt% waste loading. The vitreous ceramic waste form should meet the functional requirements for borosilicate glasses for permanent disposal in a geologic repository and for interim storage. Criticality safety would be ensured through the use of batch modes, and controlling the amount of fuel processed in one batch. The minimum requirements on SNF characterization and pretreatment, the one-step process, and minimum secondary waste generation may reduce treatment duration, radiation exposure, and treatment cost

  20. Sci-Thur PM - Colourful Interactions: Highlights 08: ARC TBI using Single-Step Optimized VMAT Fields

    International Nuclear Information System (INIS)

    Hudson, Alana; Gordon, Deborah; Moore, Roseanne; Balogh, Alex; Pierce, Greg

    2016-01-01

    Purpose: This work outlines a new TBI delivery technique to replace a lateral POP full bolus technique. The new technique is done with VMAT arc delivery, without bolus, treating the patient prone and supine. The benefits of the arc technique include: increased patient experience and safety, better dose conformity, better organ at risk sparing, decreased therapist time and reduction of therapist injuries. Methods: In this work we build on a technique developed by Jahnke et al. We use standard arc fields with gantry speeds corrected for varying distance to the patient followed by a single step VMAT optimization on a patient CT to increase dose inhomogeneity and to reduce dose to the lungs (vs. blocks). To compare the arc TBI technique to our full bolus technique, we produced plans on patient CTs for both techniques and evaluated several dosimetric parameters using an ANOVA test. Results and Conclusions: The arc technique is able reduce both the hot areas to the body (D2% reduced from 122.2% to 111.8% p<0.01) and the lungs (mean lung dose reduced from 107.5% to 99.1%, p<0.01), both statistically significant, while maintaining coverage (D98% = 97.8% vs. 94.6%, p=0.313, not statistically significant). We developed a more patient and therapist-friendly TBI treatment technique that utilizes single-step optimized VMAT plans. It was found that this technique was dosimetrically equivalent to our previous lateral technique in terms of coverage and statistically superior in terms of reduced lung dose.

  1. Sci-Thur PM - Colourful Interactions: Highlights 08: ARC TBI using Single-Step Optimized VMAT Fields

    Energy Technology Data Exchange (ETDEWEB)

    Hudson, Alana; Gordon, Deborah; Moore, Roseanne; Balogh, Alex; Pierce, Greg [Tom Baker Cancer Centre (Canada)

    2016-08-15

    Purpose: This work outlines a new TBI delivery technique to replace a lateral POP full bolus technique. The new technique is done with VMAT arc delivery, without bolus, treating the patient prone and supine. The benefits of the arc technique include: increased patient experience and safety, better dose conformity, better organ at risk sparing, decreased therapist time and reduction of therapist injuries. Methods: In this work we build on a technique developed by Jahnke et al. We use standard arc fields with gantry speeds corrected for varying distance to the patient followed by a single step VMAT optimization on a patient CT to increase dose inhomogeneity and to reduce dose to the lungs (vs. blocks). To compare the arc TBI technique to our full bolus technique, we produced plans on patient CTs for both techniques and evaluated several dosimetric parameters using an ANOVA test. Results and Conclusions: The arc technique is able reduce both the hot areas to the body (D2% reduced from 122.2% to 111.8% p<0.01) and the lungs (mean lung dose reduced from 107.5% to 99.1%, p<0.01), both statistically significant, while maintaining coverage (D98% = 97.8% vs. 94.6%, p=0.313, not statistically significant). We developed a more patient and therapist-friendly TBI treatment technique that utilizes single-step optimized VMAT plans. It was found that this technique was dosimetrically equivalent to our previous lateral technique in terms of coverage and statistically superior in terms of reduced lung dose.

  2. Penerapan Metode Diagnosis Cepat Virus Avian Influenza H5N1 dengan Metode Single Step Multiplex RT-PCR

    Directory of Open Access Journals (Sweden)

    Aris Haryanto

    2010-12-01

    Full Text Available Avian influenza (AI virus is a segmented single stranded (ss RNA virus with negative polarity andbelong to the Orthomyxoviridae family. Diagnose of AI virus can be performed using conventional methodsbut it has low sensitivity and specificity. The objective of the research was to apply rapid, precise, andaccurate diagnostic method for AI virus and also to determine its type and subtype based on the SingleStep Multiplex Reverse Transcriptase-Polymerase Chain Reaction targeting M, H5, and N1 genes. In thismethod M, H5 and NI genes were simultaneously amplified in one PCR tube. The steps of this researchconsist of collecting viral RNAs from 10 different AI samples originated from Maros Disease InvestigationCenter during 2007. DNA Amplification was conducted by Simplex RT-PCR using M primer set. Then, bysingle step multiplex RT-PCR were conducted simultaneously using M, H5 and N1 primers set. The RTPCRproducts were then separated on 1.5% agarose gel, stained by ethidum bromide and visualized underUV transilluminator. Results showed that 8 of 10 RNA virus samples could be amplified by Simplex RTPCRfor M gene which generating a DNA fragment of 276 bp. Amplification using multiplex RT-PCRmethod showed two of 10 samples were AI positive using multiplex RT-PCR, three DNA fragments weregenerated consisting of 276 bp for M gene, 189 bp for H5 gene, and 131 bp for N1. In this study, rapid andeffective diagnosis method for AI virus can be conducted by using simultaneous Single Step Multiplex RTPCR.By this technique type and subtype of AI virus, can also be determined, especially H5N1.

  3. Detecting electron neutrinos from solar dark matter annihilation by JUNO

    International Nuclear Information System (INIS)

    Guo, Wan-Lei

    2016-01-01

    We explore the electron neutrino signals from light dark matter (DM) annihilation in the Sun for the large liquid scintillator detector JUNO. In terms of the spectrum features of three typical DM annihilation channels χχ → νν-bar , τ + τ − , b b-bar , we take two sets of selection conditions to calculate the expected signals and atmospheric neutrino backgrounds based on the Monte Carlo simulation data. Then the JUNO sensitivities to the spin independent DM-nucleon and spin dependent DM-proton cross sections are presented. It is found that the JUNO projected sensitivities are much better than the current spin dependent direct detection experimental limits for the νν-bar and τ + τ − channels. In the spin independent case, the JUNO will give the better sensitivity to the DM-nucleon cross section than the LUX and CDMSlite limits for the νν-bar channel with the DM mass lighter than 6.5 GeV . If the νν-bar or τ + τ − channel is dominant, the future JUNO results are very helpful for us to understand the tension between the DAMA annual modulation signal and other direct detection exclusions

  4. Design of Pixellated CMOS Photon Detector for Secondary Electron Detection in the Scanning Electron Microscope

    Directory of Open Access Journals (Sweden)

    Joon Huang Chuah

    2011-01-01

    Full Text Available This paper presents a novel method of detecting secondary electrons generated in the scanning electron microscope (SEM. The method suggests that the photomultiplier tube (PMT, traditionally used in the Everhart-Thornley (ET detector, is to be replaced with a configurable multipixel solid-state photon detector offering the advantages of smaller dimension, lower supply voltage and power requirements, and potentially cheaper product cost. The design of the proposed detector has been implemented using a standard 0.35 μm CMOS technology with optical enhancement. This microchip comprises main circuit constituents of an array of photodiodes connecting to respective noise-optimised transimpedance amplifiers (TIAs, a selector-combiner (SC circuit, and a postamplifier (PA. The design possesses the capability of detecting photons with low input optical power in the range of 1 nW with 100 μm × 100 μm sized photodiodes and achieves a total amplification of 180 dBΩ at the output.

  5. Single-step biosynthesis and characterization of silver nanoparticles using Zornia diphylla leaves: A potent eco-friendly tool against malaria and arbovirus vectors.

    Science.gov (United States)

    Govindarajan, Marimuthu; Rajeswary, Mohan; Muthukumaran, Udaiyan; Hoti, S L; Khater, Hanem F; Benelli, Giovanni

    2016-08-01

    Mosquitoes (Diptera: Culicidae) are vectors of important pathogens and parasites, including malaria, dengue, chikungunya, Japanese encephalitis, lymphatic filariasis and Zika virus. The application of synthetic insecticides causes development of resistance, biological magnification of toxic substances through the food chain, and adverse effects on the environment and human health. In this scenario, eco-friendly control tools of mosquito vectors are a priority. Here single-step fabrication of silver nanoparticles (AgNP) using a cheap aqueous leaf extract of Zornia diphylla as reducing and capping agent pf Ag(+) ions has been carried out. Biosynthesized AgNP were characterized by UV-visible spectrophotometry, Fourier transform infrared spectroscopy (FTIR), scanning electron microscopy (SEM), transmission electron microscopy (TEM), energy-dispersive spectroscopy (EDX) and X-ray diffraction analysis (XRD). The acute toxicity of Z. diphylla leaf extract and biosynthesized AgNP was evaluated against larvae of the malaria vector Anopheles subpictus, the dengue vector Aedes albopictus and the Japanese encephalitis vector Culex tritaeniorhynchus. Both the Z. diphylla leaf extract and Ag NP showed dose dependent larvicidal effect against all tested mosquito species. Compared to the leaf aqueous extract, biosynthesized Ag NP showed higher toxicity against An. subpictus, Ae. albopictus, and Cx. tritaeniorhynchus with LC50 values of 12.53, 13.42 and 14.61μg/ml, respectively. Biosynthesized Ag NP were found safer to non-target organisms Chironomus circumdatus, Anisops bouvieri and Gambusia affinis, with the respective LC50 values ranging from 613.11 to 6903.93μg/ml, if compared to target mosquitoes. Overall, our results highlight that Z. diphylla-fabricated Ag NP are a promising and eco-friendly tool against larval populations of mosquito vectors of medical and veterinary importance, with negligible toxicity against other non-target organisms. Copyright © 2016 Elsevier B

  6. Single-Step Transepithelial PRK vs Alcohol-Assisted PRK in Myopia and Compound Myopic Astigmatism Correction.

    Science.gov (United States)

    Kaluzny, Bartlomiej J; Cieslinska, Iwona; Mosquera, Samuel A; Verma, Shwetabh

    2016-02-01

    Transepithelial photorefractive keratectomy (tPRK), where both the epithelium and stroma are removed in a single-step, is a relatively new procedure of laser refractive error correction. This study compares the 3-month results of myopia and compound myopic astigmatism correction by tPRK or conventional alcohol-assisted PRK (aaPRK).This prospective, nonrandomized, case-control study recruited 148 consecutive patients; 93 underwent tPRK (173 eyes) and 55 aaPRK (103 eyes). Refractive results, predictability, safety, and efficacy were evaluated during the 3-month follow-up. The main outcome measures were uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), and mean refractive spherical equivalent (MRSE).Mean preoperative MRSE was -4.30 ± 1.72 D and -4.33 ± 1.96 D, respectively (P = 0.87). The 3-month follow-up rate was 82.1% in the tPRK group (n = 145) and 86.4% in aaPRK group (n = 90), P = 0.81. Postoperative UDVA was 20/20 or better in 97% and 94% of eyes, respectively (P = 0.45). In the tPRK and aaPRK groups, respectively, 13% and 21% of eyes lost 1 line of CDVA, and 30% and 31% gained 1 or 2 lines (P = 0.48). Mean postoperative MRSE was -0.14 ± 0.26 D in the tPRK group and -0.12 ± 0.20 D in the aaPRK group (P = 0.9). The correlation between attempted versus achieved MRSE was equally high in both groups.Single-step transepithelial PRK and conventional PRK provide very similar results 3 months postoperatively. These procedures are predictable, effective, and safe for correction of myopia and compound myopic astigmatism.

  7. Blastocyst utilization rates after continuous culture in two commercial single-step media: a prospective randomized study with sibling oocytes.

    Science.gov (United States)

    Sfontouris, Ioannis A; Kolibianakis, Efstratios M; Lainas, George T; Venetis, Christos A; Petsas, George K; Tarlatzis, Basil C; Lainas, Tryfon G

    2017-10-01

    The aim of this study is to determine whether blastocyst utilization rates are different after continuous culture in two different commercial single-step media. This is a paired randomized controlled trial with sibling oocytes conducted in infertility patients, aged ≤40 years with ≥10 oocytes retrieved assigned to blastocyst culture and transfer. Retrieved oocytes were randomly allocated to continuous culture in either Sage one-step medium (Origio) or Continuous Single Culture (CSC) medium (Irvine Scientific) without medium renewal up to day 5 post oocyte retrieval. Main outcome measure was the proportion of embryos suitable for clinical use (utilization rate). A total of 502 oocytes from 33 women were randomly allocated to continuous culture in either Sage one-step medium (n = 250) or CSC medium (n = 252). Fertilization was performed by either in vitro fertilization or intracytoplasmic sperm injection, and embryo transfers were performed on day 5. Two patients had all blastocysts frozen due to the occurrence of severe ovarian hyperstimulation syndrome. Fertilization and cleavage rates, as well as embryo quality on day 3, were similar in the two media. Blastocyst utilization rates (%, 95% CI) [55.4% (46.4-64.1) vs 54.7% (44.9-64.6), p = 0.717], blastocyst formation rates [53.6% (44.6-62.5) vs 51.9 (42.2-61.6), p = 0.755], and proportion of good quality blastocysts [36.8% (28.1-45.4) vs 36.1% (27.2-45.0), p = 0.850] were similar in Sage one-step and CSC media, respectively. Continuous culture of embryos in Sage one-step and CSC media is associated with similar blastocyst development and utilization rates. Both single-step media appear to provide adequate support during in vitro preimplantation embryo development. Whether these observations are also valid for other continuous single medium protocols remains to be determined. NCT02302638.

  8. Electron paramagnetic resonance detection of carotenoid triplet states

    International Nuclear Information System (INIS)

    Frank, H.A.; Bolt, J.D.; deCosta, S.M.; Sauer, K.

    1980-01-01

    Triplet states of carotenoids have been detected by X-band electron paramagnetic resonance (EPR) and are reported here for the first time. The systems in which carotenoid triplets are observed include cells of photosynthetic bacteria, isolated bacteriochlorophyll-protein complexes, and detergent micelles which contain β-carotene. It is well known that if electron transfer is blocked following the initial acceptor in the bacterial photochemical reaction center, back reaction of the primary radical pair produces a bacteriochlorophyll dimer triplet. Previous optical studies have shown that in reaction centers containing carotenoids the bacteriochlorophyll dimer triplet sensitizes the carotenoid triplet. We have observed this carotenoid triplet state by EPR in reaction centers of Rhodopseudomonas sphaeroides, strain 2.4.1 (wild type), which contain the carotenoid spheroidene. The zero-field splitting parameters of the triplet spectrum are /D/ = 0.0290 +- 0.0005 cm -1 and /E/ = 0.0044 +-0.0006 cm -1 , in contrast with the parameters of the bacteriochlorophyll dimer triplet, which are /D/ = 0.0189 +- 0.0004 cm -1 and /E/ = 0.0032 +- 0.004 cm -1 . Bacteriochlorophyll in a light harvesting protein complex from Rps. sphaeroides, wild type, also sensitizes carotenoid triplet formation. In whole cells the EPR spectra vary with temperature between 100 and 10 K. Carotenoid triplets also have been observed by EPR in whole cells of Rps. sphaeroides and cells of Rhodospirillum rubrum which contain the carotenoid spirilloxanthin. Attempts to observe the triplet state EPR spectrum of β-carotene in numerous organic solvents failed. However, in nonionic detergent micelles and in phospholipid bilayer vesicles β-carotene gives a triplet state spectrum with /D/ = 0.0333 +- 0.0010 cm -1 and /E/ = 0.0037 +- 0.0010 cm -1 . 6 figures, 1 table

  9. Single-step solvothermal synthesis of mesoporous Ag-TiO2-reduced graphene oxide ternary composites with enhanced photocatalytic activity

    Science.gov (United States)

    Arif Sher Shah, Md. Selim; Zhang, Kan; Park, A. Reum; Kim, Kwang Su; Park, Nam-Gyu; Park, Jong Hyeok; Yoo, Pil J.

    2013-05-01

    With growing interest in the photocatalytic performance of TiO2-graphene composite systems, the ternary phase of TiO2, graphene, and Ag is expected to exhibit improved photocatalytic characteristics because of the improved recombination rate of photogenerated charge carriers and potential contribution of the generation of localized surface plasmon resonance at Ag sites on a surface of the TiO2-graphene binary matrix. In this work, Ag-TiO2-reduced graphene oxide ternary nanocomposites were successfully synthesized by a simple solvothermal process. In a single-step synthetic procedure, the reduction of AgNO3 and graphene oxide and the hydrolysis of titanium tetraisopropoxide were spontaneously performed in a mixed solvent system of ethylene glycol, N,N-dimethylformamide and a stoichiometric amount of water without resorting to the use of typical reducing agents. The nanocomposites were characterized by X-ray diffraction, X-ray photoelectron spectroscopy, along with different microscopic and spectroscopic techniques, enabling us to confirm the successful reduction of AgNO3 and graphite oxide to metallic Ag and reduced graphene oxide, respectively. Due to the highly facilitated electron transport of well distributed Ag nanoparticles, the synthesized ternary nanocomposite showed enhanced photocatalytic activity for degradation of rhodamine B dye under visible light irradiation.With growing interest in the photocatalytic performance of TiO2-graphene composite systems, the ternary phase of TiO2, graphene, and Ag is expected to exhibit improved photocatalytic characteristics because of the improved recombination rate of photogenerated charge carriers and potential contribution of the generation of localized surface plasmon resonance at Ag sites on a surface of the TiO2-graphene binary matrix. In this work, Ag-TiO2-reduced graphene oxide ternary nanocomposites were successfully synthesized by a simple solvothermal process. In a single-step synthetic procedure, the reduction

  10. A Single-step Process to Convert Karanja Oil to Fatty Acid Methyl Esters Using Amberlyst15 as a Catalyst

    Directory of Open Access Journals (Sweden)

    Arun K. Gupta

    2018-03-01

    Full Text Available Karanja oil was successfully converted to fatty acid methyl esters (FAME in a single- step process using Amberlyst15 as a catalyst. A methanol to oil ratio of 6 was required to retain the physical structure of the Amberlyst15 catalyst. At higher methanol to oil ratios, the Amberlyst15 catalyst disintegrated. Disintegration of Amberlyst15 caused an irreversible loss in catalytic activity. This loss in activity was due to a decrease in surface area of Amberlyst15, which was caused by a decrease in its mesoporous volume. It appeared that the chemical nature of Amberlyst15 was unaffected. Reuse of Amberlyst15 with a methanol to oil ratio of 6:1 also revealed a loss in FAME yield. However, this loss in activity was recovered by heating the used Amberlyst15 catalyst to 393 K. The kinetic parameters of a power law model were successfully determined for a methanol to oil ratio of 6:1. An activation energy of 54.9 kJ mol–1 was obtained.

  11. Single-step production of the simvastatin precursor monacolin J by engineering of an industrial strain of Aspergillus terreus.

    Science.gov (United States)

    Huang, Xuenian; Liang, Yajing; Yang, Yong; Lu, Xuefeng

    2017-07-01

    Monacolin J is a key precursor for the synthesis of simvastatin (Zocor), an important drug for treating hypercholesterolemia. Industrially, monacolin J is manufactured through alkaline hydrolysis of lovastatin, a fungal polyketide produced by Aspergillus terreus. Multistep chemical processes for the conversion of lovastatin to simvastatin are laborious, cost expensive and environmentally unfriendly. A biocatalysis process for monacolin J conversion to simvastatin has been developed. However, direct bioproduction of monacolin J has not yet been achieved. Here, we identified a lovastatin hydrolase from Penicillium chrysogenum, which displays a 232-fold higher catalytic efficiency for the in vitro hydrolysis of lovastatin compared to a previously patented hydrolase, but no activity for simvastatin. Furthermore, we showed that an industrial A. terreus strain heterologously expressing this lovastatin hydrolase can produce monacolin J through single-step fermentation with high efficiency, approximately 95% of the biosynthesized lovastatin was hydrolyzed to monacolin J. Our results demonstrate a simple and green technical route for the production of monacolin J, which makes complete bioproduction of the cholesterol-lowering drug simvastatin feasible and promising. Copyright © 2017 International Metabolic Engineering Society. Published by Elsevier Inc. All rights reserved.

  12. Single step sequential polydimethylsiloxane wet etching to fabricate a microfluidic channel with various cross-sectional geometries

    Science.gov (United States)

    Wang, C.-K.; Liao, W.-H.; Wu, H.-M.; Lo, Y.-H.; Lin, T.-R.; Tung, Y.-C.

    2017-11-01

    Polydimethylsiloxane (PDMS) has become a widely used material to construct microfluidic devices for various biomedical and chemical applications due to its desirable material properties and manufacturability. PDMS microfluidic devices are usually fabricated using soft lithography replica molding methods with master molds made of photolithogrpahy patterned photoresist layers on silicon wafers. The fabricated microfluidic channels often have rectangular cross-sectional geometries with single or multiple heights. In this paper, we develop a single step sequential PDMS wet etching process that can be used to fabricate microfluidic channels with various cross-sectional geometries from single-layer PDMS microfluidic channels. The cross-sections of the fabricated channel can be non-rectangular, and varied along the flow direction. Furthermore, the fabricated cross-sectional geometries can be numerically simulated beforehand. In the experiments, we fabricate microfluidic channels with various cross-sectional geometries using the developed technique. In addition, we fabricate a microfluidic mixer with alternative mirrored cross-sectional geometries along the flow direction to demonstrate the practical usage of the developed technique.

  13. Effect of a functional monomer (MDP) on the enamel bond durability of single-step self-etch adhesives.

    Science.gov (United States)

    Tsuchiya, Kenji; Takamizawa, Toshiki; Barkmeier, Wayne W; Tsubota, Keishi; Tsujimoto, Akimasa; Berry, Thomas P; Erickson, Robert L; Latta, Mark A; Miyazaki, Masashi

    2016-02-01

    The present study aimed to determine the effect of the functional monomer, 10-methacryloxydecyl dihydrogen phosphate (MDP), on the enamel bond durability of single-step self-etch adhesives through integrating fatigue testing and long-term water storage. An MDP-containing self-etch adhesive, Clearfil Bond SE ONE (SE), and an experimental adhesive, MDP-free (MF), which comprised the same ingredients as SE apart from MDP, were used. Shear bond strength (SBS) and shear fatigue strength (SFS) were measured with or without phosphoric acid pre-etching. The specimens were stored in distilled water for 24 h, 6 months, or 1 yr. Although similar SBS and SFS values were obtained for SE with pre-etching and for MF after 24 h of storage in distilled water, SE with pre-etching showed higher SBS and SFS values than MF after storage in water for 6 months or 1 yr. Regardless of the pre-etching procedure, SE showed higher SBS and SFS values after 6 months of storage in distilled water than after 24 h or 1 yr. To conclude, MDP might play an important role in enhancing not only bond strength but also bond durability with respect to repeated subcritical loading after long-term water storage. © 2015 Eur J Oral Sci.

  14. Single step purification of recombinant proteins using the metal ion-inducible autocleavage (MIIA) domain as linker for tag removal.

    Science.gov (United States)

    Ibe, Susan; Schirrmeister, Jana; Zehner, Susanne

    2015-08-20

    For fast and easy purification, proteins are typically fused with an affinity tag, which often needs to be removed after purification. Here, we present a method for the removal of the affinity tag from the target protein in a single step protocol. The protein VIC_001052 of the coral pathogen Vibrio coralliilyticus ATCC BAA-450 contains a metal ion-inducible autocatalytic cleavage (MIIA) domain. Its coding sequence was inserted into an expression vector for the production of recombinant fusion proteins. Following, the target proteins MalE and mCherry were produced as MIIA-Strep fusion proteins in Escherichia coli. The target proteins could be separated from the MIIA-Strep part simply by the addition of calcium or manganese(II) ions within minutes. The cleavage is not affected in the pH range from 5.0 to 9.0 or at low temperatures (6°C). Autocleavage was also observed with immobilized protein on an affinity column. The protein yield was similar to that achieved with a conventional purification protocol. Copyright © 2015 Elsevier B.V. All rights reserved.

  15. Experimental Investigation of a Base Isolation System Incorporating MR Dampers with the High-Order Single Step Control Algorithm

    Directory of Open Access Journals (Sweden)

    Weiqing Fu

    2017-03-01

    Full Text Available The conventional isolation structure with rubber bearings exhibits large deformation characteristics when subjected to infrequent earthquakes, which may lead to failure of the isolation layer. Although passive dampers can be used to reduce the layer displacement, the layer deformation and superstructure acceleration responses will increase in cases of fortification earthquakes or frequently occurring earthquakes. In addition to secondary damages and loss of life, such excessive displacement results in damages to the facilities in the structure. In order to overcome these shortcomings, this paper presents a structural vibration control system where the base isolation system is composed of rubber bearings with magnetorheological (MR damper and are regulated using the innovative control strategy. The high-order single-step algorithm with continuity and switch control strategies are applied to the control system. Shaking table test results under various earthquake conditions indicate that the proposed isolation method, compared with passive isolation technique, can effectively suppress earthquake responses for acceleration of superstructure and deformation within the isolation layer. As a result, this structural control method exhibits excellent performance, such as fast computation, generic real-time control, acceleration reduction and high seismic energy dissipation etc. The relative merits of the continuity and switch control strategies are also compared and discussed.

  16. A novel multimodal chromatography based single step purification process for efficient manufacturing of an E. coli based biotherapeutic protein product.

    Science.gov (United States)

    Bhambure, Rahul; Gupta, Darpan; Rathore, Anurag S

    2013-11-01

    Methionine oxidized, reduced and fMet forms of a native recombinant protein product are often the critical product variants which are associated with proteins expressed as bacterial inclusion bodies in E. coli. Such product variants differ from native protein in their structural and functional aspects, and may lead to loss of biological activity and immunogenic response in patients. This investigation focuses on evaluation of multimodal chromatography for selective removal of these product variants using recombinant human granulocyte colony stimulating factor (GCSF) as the model protein. Unique selectivity in separation of closely related product variants was obtained using combined pH and salt based elution gradients in hydrophobic charge induction chromatography. Simultaneous removal of process related impurities was also achieved in flow-through leading to single step purification process for the GCSF. Results indicate that the product recovery of up to 90.0% can be obtained with purity levels of greater than 99.0%. Binding the target protein at pHproduct variants using the combined pH and salt based elution gradient and removal of the host cell impurities in flow-through are the key novel features of the developed multimodal chromatographic purification step. Copyright © 2013 Elsevier B.V. All rights reserved.

  17. Fire-through Ag contact formation for crystalline Si solar cells using single-step inkjet printing.

    Science.gov (United States)

    Kim, Hyun-Gang; Cho, Sung-Bin; Chung, Bo-Mook; Huh, Joo-Youl; Yoon, Sam S

    2012-04-01

    Inkjet-printed Ag metallization is a promising method of forming front-side contacts on Si solar cells due to its non-contact printing nature and fine grid resolution. However, conventional Ag inks are unable to punch through the SiN(x) anti-reflection coating (ARC) layer on emitter Si surfaces. In this study, a novel formulation of Ag ink is examined for the formation of fire-through contacts on a SiN(x)-coated Si substrate using the single-step printing of Ag ink, followed by rapid thermal annealing at 800 degrees C. In order to formulate Ag inks with fire-through contact formation capabilities, a liquid etching agent was first formulated by dissolving metal nitrates in an organic solvent and then mixing the resulting solution with a commercial Ag nanoparticle ink at various volume ratios. During the firing process, the dissolved metal nitrates decomposed into metal oxides and acted in a similar manner to the glass frit contained in Ag pastes for screen-printed Ag metallization. The newly formulated ink with a 1 wt% loading ratio of metal oxides to Ag formed finely distributed Ag crystallites on the Si substrate after firing at 800 degrees C for 1 min.

  18. Detection of Electronic Anklet Wearers’ Groupings throughout Telematics Monitoring

    Directory of Open Access Journals (Sweden)

    Paulo Lima Machado

    2017-01-01

    Full Text Available Ankle bracelets (anklets imposed by law to track convicted individuals are being used in many countries as an alternative to overloaded prisons. There are many different systems for monitoring individuals wearing such devices, and these electronic anklet monitoring systems commonly detect violations of circulation areas permitted to holders. In spite of being able to monitor individual localization, such systems do not identify grouping activities of the monitored individuals, although this kind of event could represent a real risk of further offenses planned by those individuals. In order to address such a problem and to help monitoring systems to be able to have a proactive approach, this paper proposes sensor data fusion algorithms that are able to identify such groups based on data provided by anklet positioning devices. The results from the proposed algorithms can be applied to support risk assessment in the context of monitoring systems. The processing is performed using geographic points collected by a monitoring center, and as result, it produces a history of groups with their members, timestamps, locations and frequency of meetings. The proposed algorithms are validated in various serial and parallel computing scenarios, and the correspondent results are presented and discussed. The information produced by the proposed algorithms yields to a better characterization of the monitored individuals and can be adapted to support decision-making systems used by authorities that are responsible for planning decisions regarding actions affecting public security.

  19. Characterization of cyclic deformation behaviour of tempered and quenched 42CrMoS4 at single step and variable amplitude loading

    International Nuclear Information System (INIS)

    Schelp, M.; Eifler, D.

    2000-01-01

    Cyclic single steps tests were performed on tempered and quenched specimens of the steel 42CrMoS4. Strain, temperature and electrical resistance measurements yielded an empirical prediction of fatigue life according to Coffin, Manson and Morrow. All measured values are based on physical processes and therefore show a strong interaction. A new testing procedure was developed permitting hysteresis measurements to be used for the characterization and description of fatigue behaviour under variable amplitude loading. The basic idea is to combine fatigue tests with any kind of load spectrum with single step tests. This offers the possibility to apply lifetime prediction methods normally used for single step tests for those with random or service loading. (orig.)

  20. Solid-state flurbiprofen and methyl-β-cyclodextrin inclusion complexes prepared using a single-step, organic solvent-free supercritical fluid process.

    Science.gov (United States)

    Rudrangi, Shashi Ravi Suman; Kaialy, Waseem; Ghori, Muhammad U; Trivedi, Vivek; Snowden, Martin J; Alexander, Bruce David

    2016-07-01

    The aim of this study was to enhance the apparent solubility and dissolution properties of flurbiprofen through inclusion complexation with cyclodextrins. Especially, the efficacy of supercritical fluid technology as a preparative technique for the preparation of flurbiprofen-methyl-β-cyclodextrin inclusion complexes was evaluated. The complexes were prepared by supercritical carbon dioxide processing and were evaluated by solubility, differential scanning calorimetry, X-ray powder diffraction, scanning electron microscopy, practical yield, drug content estimation and in vitro dissolution studies. Computational molecular docking studies were conducted to study the possibility of molecular arrangement of inclusion complexes between flurbiprofen and methyl-β-cyclodextrin. The studies support the formation of stable molecular inclusion complexes between the drug and cyclodextrin in a 1:1 stoichiometry. In vitro dissolution studies showed that the dissolution properties of flurbiprofen were significantly enhanced by the binary mixtures prepared by supercritical carbon dioxide processing. The amount of flurbiprofen dissolved into solution alone was very low with 1.11±0.09% dissolving at the end of 60min, while the binary mixtures processed by supercritical carbon dioxide at 45°C and 200bar released 99.39±2.34% of the drug at the end of 30min. All the binary mixtures processed by supercritical carbon dioxide at 45°C exhibited a drug release of more than 80% within the first 10min irrespective of the pressure employed. The study demonstrated the single step, organic solvent-free supercritical carbon dioxide process as a promising approach for the preparation of inclusion complexes between flurbiprofen and methyl-β-cyclodextrin in solid-state. Copyright © 2016 Elsevier B.V. All rights reserved.

  1. Modulation transfer function and detective quantum efficiency of electron bombarded charge coupled device detector for low energy electrons

    Czech Academy of Sciences Publication Activity Database

    Horáček, Miroslav

    2005-01-01

    Roč. 76, č. 9 (2005), 093704:1-6 ISSN 0034-6748 R&D Projects: GA ČR(CZ) GA202/03/1575 Keywords : electron bombarded CCD * modulation transfer function * detective quantum efficiency Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering Impact factor: 1.235, year: 2005

  2. A high-order positivity-preserving single-stage single-step method for the ideal magnetohydrodynamic equations

    Science.gov (United States)

    Christlieb, Andrew J.; Feng, Xiao; Seal, David C.; Tang, Qi

    2016-07-01

    We propose a high-order finite difference weighted ENO (WENO) method for the ideal magnetohydrodynamics (MHD) equations. The proposed method is single-stage (i.e., it has no internal stages to store), single-step (i.e., it has no time history that needs to be stored), maintains a discrete divergence-free condition on the magnetic field, and has the capacity to preserve the positivity of the density and pressure. To accomplish this, we use a Taylor discretization of the Picard integral formulation (PIF) of the finite difference WENO method proposed in Christlieb et al. (2015) [23], where the focus is on a high-order discretization of the fluxes (as opposed to the conserved variables). We use the version where fluxes are expanded to third-order accuracy in time, and for the fluid variables space is discretized using the classical fifth-order finite difference WENO discretization. We use constrained transport in order to obtain divergence-free magnetic fields, which means that we simultaneously evolve the magnetohydrodynamic (that has an evolution equation for the magnetic field) and magnetic potential equations alongside each other, and set the magnetic field to be the (discrete) curl of the magnetic potential after each time step. In this work, we compute these derivatives to fourth-order accuracy. In order to retain a single-stage, single-step method, we develop a novel Lax-Wendroff discretization for the evolution of the magnetic potential, where we start with technology used for Hamilton-Jacobi equations in order to construct a non-oscillatory magnetic field. The end result is an algorithm that is similar to our previous work Christlieb et al. (2014) [8], but this time the time stepping is replaced through a Taylor method with the addition of a positivity-preserving limiter. Finally, positivity preservation is realized by introducing a parameterized flux limiter that considers a linear combination of high and low-order numerical fluxes. The choice of the free

  3. Electron cascades in sensors for optical detection of ionizing radiation

    International Nuclear Information System (INIS)

    London, Richard A.; Lowry, Mark E.; Vernon, Stephen P.; Stewart, Richard E.

    2013-01-01

    A new class of high-speed detectors, called RadOptic detectors, measures ionizing radiation incident on a transparent semiconductor by sensing changes in the refractive index with an optical probe beam. We describe the role of radiation-initiated electron cascades in setting the sensitivity and the spatial and temporal resolution of RadOptic detectors. We model electron cascades with both analytical and Monte Carlo computational methods. We find that the timescale for the development of an electron cascade is less than of order 100 fs and is not expected to affect the time response of a detector. The characteristic size of the electron cloud is typically less than 2 μm, enabling high spatial resolution in imaging systems. The electron-hole pair density created by single x-rays is much smaller than the saturation density and, therefore, single events should not saturate the detector

  4. A Compact and Low Cost Electronic Nose for Aroma Detection

    Directory of Open Access Journals (Sweden)

    Ramón Gallardo Caballero

    2013-04-01

    Full Text Available This article explains the development of a prototype of a portable and a very low-cost electronic nose based on an mbed microcontroller. Mbeds are a series of ARM microcontroller development boards designed for fast, flexible and rapid prototyping. The electronic nose is comprised of an mbed, an LCD display, two small pumps, two electro-valves and a sensor chamber with four TGS Figaro gas sensors. The performance of the electronic nose has been tested by measuring the ethanol content of wine synthetic matrices and special attention has been paid to the reproducibility and repeatability of the measurements taken on different days. Results show that the electronic nose with a neural network classifier is able to discriminate wine samples with 10, 12 and 14% V/V alcohol content with a classification error of less than 1%.

  5. Rapid low dose electron tomography using a direct electron detection camera

    NARCIS (Netherlands)

    V. Migunov (Vadim); H. Ryll; X. Zhuge (Jason); M. Simson; L. Strüder; K.J. Batenburg (Joost); L. Houben; R.E. Dunin-Borkowski (Rafal)

    2015-01-01

    htmlabstractWe demonstrate the ability to record a tomographic tilt series containing 3487 images in only 3.5 s by using a direct electron detector in a transmission electron microscope. The electron dose is lower by at least one order of magnitude when compared with that used to record a

  6. Determination of oil reservoir radiotracer (S{sup 14}CN{sup -}) in a single step using a plastic scintillator extractive resin

    Energy Technology Data Exchange (ETDEWEB)

    Bagan, H.; Tarancon, A. [Departament de Quimica Analitica, Universitat de Barcelona, Diagonal 645, E-08028 Barcelona (Spain); Stavsetra, L. [Department for Reservoir and Exploration Technology, Institute for Energy Technology (IFE), Instituttveien 18, N-2027 Kjeller (Norway); Rauret, G. [Departament de Quimica Analitica, Universitat de Barcelona, Diagonal 645, E-08028 Barcelona (Spain); Garcia, J.F., E-mail: jfgarcia@ub.edu [Departament de Quimica Analitica, Universitat de Barcelona, Diagonal 645, E-08028 Barcelona (Spain)

    2012-07-29

    Highlights: Black-Right-Pointing-Pointer A new procedure for S{sup 14}CN{sup -} radiotracer determination using PS resin was established. Black-Right-Pointing-Pointer The minimum detectable activity for a 100 mL sample is 0.08 Bq L{sup -1}. Black-Right-Pointing-Pointer The minimum quantifiable activity for a 100 mL sample is 0.31 Bq L{sup -1}. Black-Right-Pointing-Pointer PS resin is capable to quantify S{sup 14}CN{sup -} radiotracer samples with errors lower than 5%. Black-Right-Pointing-Pointer PS resin is also capable to quantify complex matrices obtained from oil reservoirs. - Abstract: The analysis of radiotracers is important in the study of oil reservoir dynamics. One of the most widely used radiotracer is S{sup 14}CN{sup -}. Prior to activity measurements by Liquid Scintillation (LS), routine determinations require the pretreatment steps of purification and concentration of the samples using anion exchange columns. The final elution media produces samples with high salt concentration that may lead to problems with phase separation during the LS measurement. Plastic Scintillation (PS) is an alternative technique that provides a solid surface that can be used as a platform for the immobilisation of selective extractants to obtain a PS resin. The proposed procedure unifies chemical separation and sample measurement preparation in a single step, serving to reduce the number of reagents needed and manpower required for the analysis while also avoiding mixed waste production by LS. The objective of this study is to develop a PS resin for the determination of {sup 14}C-labelled thiocyanate radiotracer in water samples. For this purpose, the immobilisation procedure was optimised, including optimisation of the proportion of PS microspheres:extractant and the use of a control blank to monitor the PS resin immobilisation process. The breakthrough volume was studied and the detection and quantification limits for 100 mL of sample were determined to be 0.08 Bq L{sup -1

  7. Modulation transfer function and detective quantum efficiency of electron bombarded charge coupled device detector for low energy electrons

    International Nuclear Information System (INIS)

    Horacek, Miroslav

    2005-01-01

    The use of a thinned back-side illuminated charge coupled device chip as two-dimensional sensor working in direct electron bombarded mode at optimum energy of the incident signal electrons is demonstrated and the measurements of the modulation transfer function (MTF) and detective quantum efficiency (DQE) are described. The MTF was measured for energy of electrons 4 keV using an edge projection method and a stripe projection method. The decrease of the MTF for a maximum spatial frequency of 20.8 cycles/mm, corresponding to the pixel size 24x24 μm, is 0.75≅-2.5 dB, and it is approximately the same for both horizontal and vertical directions. DQE was measured using an empty image and the mixing factor method. Empty images were acquired for energies of electrons from 2 to 5 keV and for various doses, ranging from nearly dark image to a nearly saturated one. DQE increases with increasing energy of bombarded electrons and reaches 0.92 for electron energy of 5 keV. For this energy the detector will be used for the angle- and energy-selective detection of signal electrons in the scanning low energy electron microscope

  8. Microchannel electron multiplier: improvement in gain performances and detection dynamics

    International Nuclear Information System (INIS)

    Audier, M.; Delmotte, J.C.; Boutot, J.P.

    1978-01-01

    The performances of an MCP are a function of its geometrical characteristics (diameter d and ratio 1/d of a channel, useful area) and of the applied voltage. Gain and mean output current are limited by saturation phenomena. By using a particular cascaded MCP's configuration, it is possible to simultaneously improve the gain, its associated fluctuations and the detection dynamics (detected level, counting rate). For gains 10 6 7 , the fluctuations, can be kept as low as 20% and an improvement by a factor > 10 can be obtained on the detection dynamics [fr

  9. Counterfeit Electronics Detection Using Image Processing and Machine Learning

    Science.gov (United States)

    Asadizanjani, Navid; Tehranipoor, Mark; Forte, Domenic

    2017-01-01

    Counterfeiting is an increasing concern for businesses and governments as greater numbers of counterfeit integrated circuits (IC) infiltrate the global market. There is an ongoing effort in experimental and national labs inside the United States to detect and prevent such counterfeits in the most efficient time period. However, there is still a missing piece to automatically detect and properly keep record of detected counterfeit ICs. Here, we introduce a web application database that allows users to share previous examples of counterfeits through an online database and to obtain statistics regarding the prevalence of known defects. We also investigate automated techniques based on image processing and machine learning to detect different physical defects and to determine whether or not an IC is counterfeit.

  10. Counterfeit Electronics Detection Using Image Processing and Machine Learning

    International Nuclear Information System (INIS)

    Asadizanjani, Navid; Tehranipoor, Mark; Forte, Domenic

    2017-01-01

    Counterfeiting is an increasing concern for businesses and governments as greater numbers of counterfeit integrated circuits (IC) infiltrate the global market. There is an ongoing effort in experimental and national labs inside the United States to detect and prevent such counterfeits in the most efficient time period. However, there is still a missing piece to automatically detect and properly keep record of detected counterfeit ICs. Here, we introduce a web application database that allows users to share previous examples of counterfeits through an online database and to obtain statistics regarding the prevalence of known defects. We also investigate automated techniques based on image processing and machine learning to detect different physical defects and to determine whether or not an IC is counterfeit. (paper)

  11. Single-Step Syngas-to-Distillates (S2D) Synthesis via Methanol and Dimethyl Ether Intermediates: Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Dagle, Robert A.; Lebarbier, Vanessa MC; Lizarazo Adarme, Jair A.; King, David L.; Zhu, Yunhua; Gray, Michel J.; Jones, Susanne B.; Biddy, Mary J.; Hallen, Richard T.; Wang, Yong; White, James F.; Holladay, Johnathan E.; Palo, Daniel R.

    2013-11-26

    would be allowed for methanol synthesis alone. Aromatic-rich hydrocarbon liquid (C5+), containing a significant amount of methylated benzenes, was produced under these conditions. However, selectivity control to liquid hydrocarbons was difficult to achieve. Carbon dioxide and methane formation was problematic. Furthermore, saturation of the olefinic intermediates formed in the zeolite, and necessary for gasoline production, occurred over PdZnAl. Thus, yield to desirable hydrocarbon liquid product was limited. Evaluation of other oxygenate-producing catalysts could possibly lead to future advances. Potential exists with discovery of other types of catalysts that suppress carbon dioxide and light hydrocarbon formation. Comparative techno-economics for a single-step syngas-to-distillates process and a more conventional MTG-type process were investigated. Results suggest operating and capital cost savings could only modestly be achieved, given future improvements to catalyst performance. Sensitivity analysis indicated that increased single-pass yield to hydrocarbon liquid is a primary need for this process to achieve cost competiveness.

  12. Direct single electron detection with a CMOS detector for electron microscopy

    International Nuclear Information System (INIS)

    Faruqi, A.R.; Henderson, R.; Pryddetch, M.; Allport, P.; Evans, A.

    2005-01-01

    We report the results of an investigation into the use of a monolithic active pixel sensor (MAPS) for electron microscopy. MAPS, designed originally for astronomers at the Rutherford Appleton Laboratories, was installed in a 120 kV electron microscope (Philips CM12) at the MRC Laboratory in Cambridge for tests which included recording single electrons at 40 and 120 keV, and measuring signal-to-noise ratio (SNR), spatial resolution and radiation sensitivity. Our results show that, due to the excellent SNR and resolution, it is possible to register single electrons. The radiation damage to the detector is apparent with low doses and gets progressively greater so that its lifetime is limited to 600,000-900,000 electrons/pixel (very approximately 10-15 krad). Provided this detector can be radiation hardened to reduce its radiation sensitivity several hundred fold and increased in size, it will provide excellent performance for all types of electron microscopy

  13. Detection and characterisation of radicals using electron paramagnetic resonance (EPR) spin trapping and related methods

    DEFF Research Database (Denmark)

    Davies, Michael Jonathan

    2016-01-01

    Electron paramagnetic resonance (EPR) spectroscopy (also known as electron spin resonance, ESR, or electron magnetic resonance, EMR, spectroscopy) is often described as the “gold standard” for the detection and characterisation of radicals in chemical, biological and medical systems. The article...... reviews aspects of EPR spectroscopy and discusses how this methodology and related techniques can be used to obtain useful information from biological systems. Consideration is given to the direct detection of radicals, the use of spin traps and the detection of nitric oxide, and the advantages...

  14. A single step reversed-phase high performance liquid chromatography separation of polar and non-polar lipids.

    Science.gov (United States)

    Olsson, Petter; Holmbäck, Jan; Herslöf, Bengt

    2014-11-21

    This paper reports a simple chromatographic system to separate lipids classes as well as their molecular species. By the use of phenyl coated silica as stationary phase in combination with a simple mobile phase consisting of methanol and water, all tested lipid classes elute within 30 min. Furthermore, a method to accurately predict retention times of specific lipid components for this type of chromatography is presented. Common detection systems were used, namely evaporative light scattering detection (ELSD), charged aerosol detection (CAD), electrospray mass spectrometry (ESI-MS), and UV detection. Copyright © 2014 Elsevier B.V. All rights reserved.

  15. Genome-wide association mapping including phenotypes from relatives without genotypes in a single-step (ssGWAS for 6-week body weight in broiler chickens

    Directory of Open Access Journals (Sweden)

    Huiyu eWang

    2014-05-01

    Full Text Available The purpose of this study was to compare results obtained from various methodologies for genome-wide association studies, when applied to real data, in terms of number and commonality of regions identified and their genetic variance explained, computational speed, and possible pitfalls in interpretations of results. Methodologies include: two iteratively reweighted single-step genomic BLUP procedures (ssGWAS1 and ssGWAS2, a single-marker model (CGWAS, and BayesB. The ssGWAS methods utilize genomic breeding values (GEBVs based on combined pedigree, genomic and phenotypic information, while CGWAS and BayesB only utilize phenotypes from genotyped animals or pseudo-phenotypes. In this study, ssGWAS was performed by converting GEBVs to SNP marker effects. Unequal variances for markers were incorporated for calculating weights into a new genomic relationship matrix. SNP weights were refined iteratively. The data was body weight at 6 weeks on 274,776 broiler chickens, of which 4553 were genotyped using a 60k SNP chip. Comparison of genomic regions was based on genetic variances explained by local SNP regions (20 SNPs. After 3 iterations, the noise was greatly reduced of ssGWAS1 and results are similar to that of CGWAS, with 4 out of the top 10 regions in common. In contrast, for BayesB, the plot was dominated by a single region explaining 23.1% of the genetic variance. This same region was found by ssGWAS1 with the same rank, but the amount of genetic variation attributed to the region was only 3%. These finding emphasize the need for caution when comparing and interpreting results from various methods, and highlight that detected associations, and strength of association, strongly depends on methodologies and details of implementations. BayesB appears to overly shrink regions to zero, while overestimating the amount of genetic variation attributed to the remaining SNP effects. The real world is most likely a compromise between methods and remains to

  16. Electron Jet Detected by MMS at Dipolarization Front

    Science.gov (United States)

    Liu, C. M.; Fu, H. S.; Vaivads, A.; Khotyaintsev, Y. V.; Gershman, D. J.; Hwang, K.-J.; Chen, Z. Z.; Cao, D.; Xu, Y.; Yang, J.; Peng, F. Z.; Huang, S. Y.; Burch, J. L.; Giles, B. L.; Ergun, R. E.; Russell, C. T.; Lindqvist, P.-A.; Le Contel, O.

    2018-01-01

    Using MMS high-resolution measurements, we present the first observation of fast electron jet (Ve 2,000 km/s) at a dipolarization front (DF) in the magnetotail plasma sheet. This jet, with scale comparable to the DF thickness ( 0.9 di), is primarily in the tangential plane to the DF current sheet and mainly undergoes the E × B drift motion; it contributes significantly to the current system at the DF, including a localized ring-current that can modify the DF topology. Associated with this fast jet, we observed a persistent normal electric field, strong lower hybrid drift waves, and strong energy conversion at the DF. Such strong energy conversion is primarily attributed to the electron-jet-driven current (E ṡ je ≈ 2 E ṡ ji), rather than the ion current suggested in previous studies.

  17. Synergistic electron transfer effect-based signal amplification strategy for the ultrasensitive detection of dopamine.

    Science.gov (United States)

    Lu, Qiujun; Chen, Xiaogen; Liu, Dan; Wu, Cuiyan; Liu, Meiling; Li, Haitao; Zhang, Youyu; Yao, Shouzhuo

    2018-05-15

    The selective and sensitive detection of dopamine (DA) is of great significance for the identification of schizophrenia, Huntington's disease, and Parkinson's disease from the perspective of molecular diagnostics. So far, most of DA fluorescence sensors are based on the electron transfer from the fluorescence nanomaterials to DA-quinone. However, the limited electron transfer ability of the DA-quinone affects the level of detection sensitivity of these sensors. In this work, based on the DA can reduce Ag + into AgNPs followed by oxidized to DA-quinone, we developed a novel silicon nanoparticles-based electron transfer fluorescent sensor for the detection of DA. As electron transfer acceptor, the AgNPs and DA-quinone can quench the fluorescence of silicon nanoparticles effectively through the synergistic electron transfer effect. Compared with traditional fluorescence DA sensors, the proposed synergistic electron transfer-based sensor improves the detection sensitivity to a great extent (at least 10-fold improvement). The proposed sensor shows a low detection limit of DA, which is as low as 0.1 nM under the optimal conditions. This sensor has potential applicability for the detection of DA in practical sample. This work has been demonstrated to contribute to a substantial improvement in the sensitivity of the sensors. It also gives new insight into design electron transfer-based sensors. Copyright © 2018. Published by Elsevier B.V.

  18. Detection of ordering of electrons on liquid helium

    International Nuclear Information System (INIS)

    Deville, G.; Gallet, F.; Marty, D.; Poitrenaud, J.; Valdes, A.; Williams, F.I.B.

    1980-05-01

    The ordering is observed for surface densities 1.5 10 8 8 cm -2 at temperatures 0.3 < T < 0.8 K by monitoring the response to a 25 MHz in plane electric field polarized parallel to its wave vector. Ordering influences this susceptibility by the shift in frequency of the plasmon modes as the electrons correlate and so self-trap into the surface deformation they impose on the helium. This experiment is sensitive to the optical mode of the coupled systems (electron and surface deformation move in antiphase), whereas the first observation of ordering by Grimes and Adams was based on the appearance of the acoustical modes (electron + deformation move in phase). Our results for the ordering temperatures can be expressed by n(c) approximately T(c)sup(1.8+-0.2), or, if one fits the results GAMMA(c)=118+-10. It seems that the optical modes establish themselves before the acoustic modes

  19. Detecting Electron Transport of Amino Acids by Using Conductance Measurement

    Directory of Open Access Journals (Sweden)

    Wei-Qiong Li

    2017-04-01

    Full Text Available The single molecular conductance of amino acids was measured by a scanning tunneling microscope (STM break junction. Conductance measurement of alanine gives out two conductance values at 10−1.85 G0 (1095 nS and 10−3.7 G0 (15.5 nS, while similar conductance values are also observed for aspartic acid and glutamic acid, which have one more carboxylic acid group compared with alanine. This may show that the backbone of NH2–C–COOH is the primary means of electron transport in the molecular junction of aspartic acid and glutamic acid. However, NH2–C–COOH is not the primary means of electron transport in the methionine junction, which may be caused by the strong interaction of the Au–SMe (methyl sulfide bond for the methionine junction. The current work reveals the important role of the anchoring group in the electron transport in different amino acids junctions.

  20. Single-step synthesis of [18F]haloperidol from the chloro-precursor and its applications in PET imaging of a cat's brain

    International Nuclear Information System (INIS)

    Hashizume, Kazunari; Tamakawa, Hiroki; Hashimoto, Naoto; Miyake, Yoshihiro

    1997-01-01

    We have established a convenient synthesis process for the synthesis of [ 18 F]haloperidol using a single-step 18 F - for -Cl exchange reaction and a new elution system for the preparative high performance liquid chromatography (HPLC) using C18 bonded vinylalcohol copolymer gel (ODP) and a basic eluent. We successfully applied the product to cat-PET study and got clear images of the striatum, showing the usefulness of this synthesis. (author)

  1. Single-step preparation of TiO2/MWCNT Nanohybrid materials by laser pyrolysis and application to efficient photovoltaic energy conversion.

    Science.gov (United States)

    Wang, Jin; Lin, Yaochen; Pinault, Mathieu; Filoramo, Arianna; Fabert, Marc; Ratier, Bernard; Bouclé, Johann; Herlin-Boime, Nathalie

    2015-01-14

    This paper presents the continuous-flowand single-step synthesis of a TiO2/MWCNT (multiwall carbon nanotubes) nanohybrid material. The synthesis method allows achieving high coverage and intimate interface between the TiO2particles and MWCNTs, together with a highly homogeneous distribution of nanotubes within the oxide. Such materials used as active layer in theporous photoelectrode of solid-state dye-sensitized solar cells leads to a substantial performance improvement (20%) as compared to reference devices.

  2. Single-step synthesis of [{sup 18}F]haloperidol from the chloro-precursor and its applications in PET imaging of a cat`s brain

    Energy Technology Data Exchange (ETDEWEB)

    Hashizume, Kazunari; Tamakawa, Hiroki; Hashimoto, Naoto; Miyake, Yoshihiro [National Cardiovascular Center, Suita (Japan). Inst. of Biofunctional Research

    1997-09-01

    We have established a convenient synthesis process for the synthesis of [{sup 18}F]haloperidol using a single-step {sup 18}F - for -Cl exchange reaction and a new elution system for the preparative high performance liquid chromatography (HPLC) using C18 bonded vinylalcohol copolymer gel (ODP) and a basic eluent. We successfully applied the product to cat-PET study and got clear images of the striatum, showing the usefulness of this synthesis. (author).

  3. Observation of strongly forbidden solid effect dynamic nuclear polarization transitions via electron-electron double resonance detected NMR

    Energy Technology Data Exchange (ETDEWEB)

    Smith, Albert A.; Corzilius, Björn; Haze, Olesya; Swager, Timothy M.; Griffin, Robert G., E-mail: rgg@mit.edu [Department of Chemistry and Francis Bitter Magnet Laboratory, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139 (United States)

    2013-12-07

    We present electron paramagnetic resonance experiments for which solid effect dynamic nuclear polarization transitions were observed indirectly via polarization loss on the electron. This use of indirect observation allows characterization of the dynamic nuclear polarization (DNP) process close to the electron. Frequency profiles of the electron-detected solid effect obtained using trityl radical showed intense saturation of the electron at the usual solid effect condition, which involves a single electron and nucleus. However, higher order solid effect transitions involving two, three, or four nuclei were also observed with surprising intensity, although these transitions did not lead to bulk nuclear polarization—suggesting that higher order transitions are important primarily in the transfer of polarization to nuclei nearby the electron. Similar results were obtained for the SA-BDPA radical where strong electron-nuclear couplings produced splittings in the spectrum of the indirectly observed solid effect conditions. Observation of high order solid effect transitions supports recent studies of the solid effect, and suggests that a multi-spin solid effect mechanism may play a major role in polarization transfer via DNP.

  4. Detecting single-electron events in TEM using low-cost electronics and a silicon strip sensor.

    Science.gov (United States)

    Gontard, Lionel C; Moldovan, Grigore; Carmona-Galán, Ricardo; Lin, Chao; Kirkland, Angus I

    2014-04-01

    There is great interest in developing novel position-sensitive direct detectors for transmission electron microscopy (TEM) that do not rely in the conversion of electrons into photons. Direct imaging improves contrast and efficiency and allows the operation of the microscope at lower energies and at lower doses without loss in resolution, which is especially important for studying soft materials and biological samples. We investigate the feasibility of employing a silicon strip detector as an imaging detector for TEM. This device, routinely used in high-energy particle physics, can detect small variations in electric current associated with the impact of a single charged particle. The main advantages of using this type of sensor for direct imaging in TEM are its intrinsic radiation hardness and large detection area. Here, we detail design, simulation, fabrication and tests in a TEM of the front-end electronics developed using low-cost discrete components and discuss the limitations and applications of this technology for TEM.

  5. Gravitational wave detection by bounded cold electronic plasma in a long pipe

    OpenAIRE

    Jalili, O.; Rouhani, S.; Takook, M. V.

    2013-01-01

    We intend to propose an experimental sketch to detect gravitational waves (GW) directly, using an cold electronic plasma in a long pipe. By considering an cold electronic plasma in a long pipe, the Maxwell equations in 3+1 formalism will be invoked to relate gravitational waves to the perturbations of plasma particles. It will be shown that the impact of GW on cold electronic plasma causes disturbances on the paths of the electrons. Those electrons that absorb energy from GW will pass through...

  6. A printed electronic platform for the specific detection of biomolecules

    Science.gov (United States)

    Doumbia, A.; Webb, M.; Turner, M. L.; Behrendt, J. M.; Wilson, R.

    2017-08-01

    The rapid detection of disease specific biomarkers in a clinically relevant range using a low-cost sensor can facilitate the development of individual treatment plans for a given patient, known as precision, personalized or genomic medicine. In the recent decade Electrolyte-Gated Organic Field Effect Transistors (EGOFETs), a subtype of OFETs where the dielectric is replaced by an electrolyte, have attracted a great deal of attention for sensing applications. This is due to their capacity to operate at low voltage (market are not yet achieved. In this contribution, we describe the development of a stable and reproducible EGOFET sensor that is able to detect biomolecules selectively in real-time. Facile and scalable techniques are used to prepare arrays of these devices. The selectivity of individual EGOFETs is investigated by immobilization of specific ligands to the target molecule of interest on the gate electrode within a microfluidic flow cell.

  7. Bidirectional RNN for Medical Event Detection in Electronic Health Records.

    Science.gov (United States)

    Jagannatha, Abhyuday N; Yu, Hong

    2016-06-01

    Sequence labeling for extraction of medical events and their attributes from unstructured text in Electronic Health Record (EHR) notes is a key step towards semantic understanding of EHRs. It has important applications in health informatics including pharmacovigilance and drug surveillance. The state of the art supervised machine learning models in this domain are based on Conditional Random Fields (CRFs) with features calculated from fixed context windows. In this application, we explored recurrent neural network frameworks and show that they significantly out-performed the CRF models.

  8. Electronic aroma detection technology for forensic and law enforcement applications

    Energy Technology Data Exchange (ETDEWEB)

    Barshick, S.-A.; Griest, W.H.; Vass, A.A.

    1996-12-31

    A major problem hindering criminal investigations is the lack of appropriate tools for proper crime scene investigations. Often locating important pieces of evidence means relying on the ability of trained detection canines. Development of analytical technology to uncover and analyze evidence, potentially at the scene, could serve to expedite criminal investigations, searches, and court proceedings. To address this problem, a new technology based on gas sensor arrays was investigated for its applicability to forensic and law enforcement problems. The technology employs an array of sensors that respond to volatile chemical components yielding a characteristic `fingerprint` pattern representative of the vapor- phase composition of a sample. Sample aromas can be analyzed and identified using artificial neural networks that are trained on known aroma patterns. Several candidate applications based on known technological needs of the forensic and law enforcement communities have been investigated. These applications have included the detection of aromas emanating from cadavers to aid in determining time since death, drug detection for deterring the manufacture, sale, and use of drugs of abuse, and the analysis of fire debris for accelerant identification. The results to date for these applications have been extremely promising and demonstrate the potential applicability of this technology for forensic use.

  9. Application of Electronic Noses for Disease Diagnosis and Food Spoilage Detection

    OpenAIRE

    Casalinuovo, Ida A.; Di Pierro, Donato; Coletta, Massimiliano; Di Francesco, Paolo

    2006-01-01

    Over the last twenty years, newly developed chemical sensor systems (so-called “electronic noses”) have odour analyses made possible. This paper describes the applications of these systems for microbial detection in different fields such as medicine and the food industry, where fast detection methods are essential for appropriate management of health care. Several groups have employed different electronic noses for classification and quantification of bacteria and fungi to obtain accurate med...

  10. Robust membrane detection based on tensor voting for electron tomography.

    Science.gov (United States)

    Martinez-Sanchez, Antonio; Garcia, Inmaculada; Asano, Shoh; Lucic, Vladan; Fernandez, Jose-Jesus

    2014-04-01

    Electron tomography enables three-dimensional (3D) visualization and analysis of the subcellular architecture at a resolution of a few nanometers. Segmentation of structural components present in 3D images (tomograms) is often necessary for their interpretation. However, it is severely hampered by a number of factors that are inherent to electron tomography (e.g. noise, low contrast, distortion). Thus, there is a need for new and improved computational methods to facilitate this challenging task. In this work, we present a new method for membrane segmentation that is based on anisotropic propagation of the local structural information using the tensor voting algorithm. The local structure at each voxel is then refined according to the information received from other voxels. Because voxels belonging to the same membrane have coherent structural information, the underlying global structure is strengthened. In this way, local information is easily integrated at a global scale to yield segmented structures. This method performs well under low signal-to-noise ratio typically found in tomograms of vitrified samples under cryo-tomography conditions and can bridge gaps present on membranes. The performance of the method is demonstrated by applications to tomograms of different biological samples and by quantitative comparison with standard template matching procedure. Copyright © 2014 Elsevier Inc. All rights reserved.

  11. Minimum detection limit and spatial resolution of thin-sample field-emission electron probe microanalysis

    International Nuclear Information System (INIS)

    Kubo, Yugo; Hamada, Kotaro; Urano, Akira

    2013-01-01

    The minimum detection limit and spatial resolution for a thinned semiconductor sample were determined by electron probe microanalysis (EPMA) using a Schottky field emission (FE) electron gun and wavelength dispersive X-ray spectrometry. Comparison of the FE-EPMA results with those obtained using energy dispersive X-ray spectrometry in conjunction with scanning transmission electron microscopy, confirmed that FE-EPMA is largely superior in terms of detection sensitivity. Thin-sample FE-EPMA is demonstrated as a very effective method for high resolution, high sensitivity analysis in a laboratory environment because a high probe current and high signal-to-noise ratio can be achieved. - Highlights: • Minimum detection limit and spatial resolution determined for FE-EPMA. • Detection sensitivity of FE-EPMA greatly superior to that of STEM-EDX. • Minimum detection limit and spatial resolution controllable by probe current

  12. A study of the possibility of using BEBC to detect prompt electrons

    International Nuclear Information System (INIS)

    Crennell, D.J.

    1976-07-01

    A method is described for the simulation of bubble chamber pictures. This method is used to find the sensitivity for the detection of electrons directly produced in 40 GeV/c π - interactions in the track sensitive hydrogen target (TST) inside the Big European Bubble Chamber (BEBC). At this energy the efficiency of seeing electrons is approximately 90%. (author)

  13. Alpha-particle detection based on the BJT detector and simple, IC-based readout electronics

    Energy Technology Data Exchange (ETDEWEB)

    Rovati, L; Bonaiuti, M [Dipartimento di Ingegneria dell' Informazione, Universita di Modena e Reggio Emilia, Modena (Italy); Bettarini, S [Dipartimento di Fisica, Universita di Pisa and INFN Pisa, Pisa (Italy); Bosisio, L [Dipartimento di Fisica, Universita di Trieste and INFN Trieste, Trieste (Italy); Dalla Betta, G-F; Tyzhnevyi, V [Dipartimento di Ingegneria e Scienza dell' Informazione, Universita di Trento e INFN Trento, Trento (Italy); Verzellesi, G [Dipartimento di Scienze e Metodi dell' Ingegneria, Universita di Modena e Reggio Emilia and INFN Trento, Reggio Emilia (Italy); Zorzi, N, E-mail: giovanni.verzellesi@unimore.i [Fondazione Bruno Kessler (FBK), Trento (Italy)

    2009-11-15

    In this paper we propose a portable instrument for alpha-particle detection based on a previously-developed BJT detector and a simple, IC-based readout electronics. Experimental tests of the BJT detector and readout electronics are reported. Numerical simulations are adopted to predict the performance enhancement achievable with optimized BJT detectors.

  14. Alpha-particle detection based on the BJT detector and simple, IC-based readout electronics

    International Nuclear Information System (INIS)

    Rovati, L; Bonaiuti, M; Bettarini, S; Bosisio, L; Dalla Betta, G-F; Tyzhnevyi, V; Verzellesi, G; Zorzi, N

    2009-01-01

    In this paper we propose a portable instrument for alpha-particle detection based on a previously-developed BJT detector and a simple, IC-based readout electronics. Experimental tests of the BJT detector and readout electronics are reported. Numerical simulations are adopted to predict the performance enhancement achievable with optimized BJT detectors.

  15. Measurement of single electron and nuclear spin states based on optically detected magnetic resonance

    Energy Technology Data Exchange (ETDEWEB)

    Berman, Gennady P [Los Alamos National Laboratory, Los Alamos, NM 87545 (United States); Bishop, Alan R [Los Alamos National Laboratory, Los Alamos, NM 87545 (United States); Chernobrod, Boris M [Los Alamos National Laboratory, Los Alamos, NM 87545 (United States); Hawley, Marilyn E [Los Alamos National Laboratory, Los Alamos, NM 87545 (United States); Brown, Geoffrey W [Los Alamos National Laboratory, Los Alamos, NM 87545 (United States); Tsifrinovich, Vladimir I [Polytechnic University, Brooklyn, NY 11201 (United States)

    2006-05-15

    A novel approach for measurement of single electron and nuclear spin states is suggested. Our approach is based on optically detected magnetic resonance in a nano-probe located at the apex of an AFM tip. The method provides single electron spin sensitivity with nano-scale spatial resolution.

  16. Measurement of single electron and nuclear spin states based on optically detected magnetic resonance

    International Nuclear Information System (INIS)

    Berman, Gennady P; Bishop, Alan R; Chernobrod, Boris M; Hawley, Marilyn E; Brown, Geoffrey W; Tsifrinovich, Vladimir I

    2006-01-01

    A novel approach for measurement of single electron and nuclear spin states is suggested. Our approach is based on optically detected magnetic resonance in a nano-probe located at the apex of an AFM tip. The method provides single electron spin sensitivity with nano-scale spatial resolution

  17. Electronic THz-spectrometer for plasmonic enhanced deep subwavelength layer detection

    NARCIS (Netherlands)

    Berrier, A.; Schaafsma, M.C.; Gómez Rivas, J.; Schäfer-Eberwein, H.; Haring Bolivar, P.; Tripodi, L.; Matters-Kammerer, M.K.

    2015-01-01

    We demonstrate the operation of a miniaturized all-electronic CMOS based THz spectrometer with performances comparable to that of a THz-TDS spectrometer in the frequency range 20 to 220 GHz. The use of this all-electronic THz spectrometer for detection of a thin TiO2 layer and a B. subtilis bacteria

  18. Determination of local absolute detection efficiency of a ceratron with 55Fe Auger electrons

    International Nuclear Information System (INIS)

    Mori, C.; Sugiyama, T.; Watanabe, T.

    1983-01-01

    The local absolute detection efficiency of a Ceratron (channel electron multiplier made of ceramics) was determined with collimated Mn K Auger electrons ( 5 keV) emitted from 55 Fe as a function of electron incident position and applied voltage. The local efficiency at the channel inlet did not depend so much on the applied voltage. The efficiency at the funnel increased with the applied voltage, while it was always lower than that at the channel inlet. (orig.)

  19. The electronics of the INDRA 4π detection array

    International Nuclear Information System (INIS)

    Pouthas, J.; Bertaut, A.; Bourgault, P.; Martina, L.; Olivier, L.; Piquet, B.; Plagnol, E.; Raine, B.; Saint-Laurent, F.; Spitaels, C.

    1995-01-01

    The INDRA multidetector is composed of 96 ionization chambers, 196 silicon detectors, 324 CsI(Tl) scintillators and 12 NE102/NE115 phoswich detectors. The associated electronics is presented. The signal treatment is performed through specifically designed modules, most of which are in the new VXIbus standard. The large dynamic range required for the silicon detectors is reached by means of a low noise amplifier providing a unipolar signal which is charge integrated and converted on two dynamic ranges. The trigger system relies on a new working mode called 'asynchronous mode' and performs event selections based on multiplicity functions which are built up from subgroups of detectors. The performances of the data acquisition and the graphical software packages are also presented. (author)

  20. The electronics of the INDRA 4{pi} detection array

    Energy Technology Data Exchange (ETDEWEB)

    Pouthas, J.; Bertaut, A.; Bourgault, P.; Martina, L.; Olivier, L.; Piquet, B.; Plagnol, E.; Raine, B.; Saint-Laurent, F.; Spitaels, C. [and others

    1995-12-31

    The INDRA multidetector is composed of 96 ionization chambers, 196 silicon detectors, 324 CsI(Tl) scintillators and 12 NE102/NE115 phoswich detectors. The associated electronics is presented. The signal treatment is performed through specifically designed modules, most of which are in the new VXIbus standard. The large dynamic range required for the silicon detectors is reached by means of a low noise amplifier providing a unipolar signal which is charge integrated and converted on two dynamic ranges. The trigger system relies on a new working mode called `asynchronous mode` and performs event selections based on multiplicity functions which are built up from subgroups of detectors. The performances of the data acquisition and the graphical software packages are also presented. (author). 22 refs. Submitted to Nuclear Instruments and Methods (NL).

  1. Detection of bump-on-tail reduced electron velocity distributions at the electron foreshock boundary

    International Nuclear Information System (INIS)

    Fitzenreiter, R.J.; Klimas, A.J.; Scudder, J.D.

    1984-02-01

    Reduced velocity distributions are derived from three-dimensional measurements of the velocity distribution of electrons in the 7 to 500 eV range in the electron foreshock. Bump-on-tail reduced distributions are presented for the first time at the foreshock boundary consistent with Filbert and Kellogg's proposed time-of-flight mechanism for generating the electron beams. In a significant number of boundary crossings, bump-on-tail reduced distributions were found in consecutive 3 sec measurements made 9 sec apart. It is concluded that, although the beams are linearly unstable to plasma waves according to the Penrose criterion, they persist on a time scale of 3 to 15 sec

  2. Detecting Inappropriate Access to Electronic Health Records Using Collaborative Filtering.

    Science.gov (United States)

    Menon, Aditya Krishna; Jiang, Xiaoqian; Kim, Jihoon; Vaidya, Jaideep; Ohno-Machado, Lucila

    2014-04-01

    Many healthcare facilities enforce security on their electronic health records (EHRs) through a corrective mechanism: some staff nominally have almost unrestricted access to the records, but there is a strict ex post facto audit process for inappropriate accesses, i.e., accesses that violate the facility's security and privacy policies. This process is inefficient, as each suspicious access has to be reviewed by a security expert, and is purely retrospective, as it occurs after damage may have been incurred. This motivates automated approaches based on machine learning using historical data. Previous attempts at such a system have successfully applied supervised learning models to this end, such as SVMs and logistic regression. While providing benefits over manual auditing, these approaches ignore the identity of the users and patients involved in a record access. Therefore, they cannot exploit the fact that a patient whose record was previously involved in a violation has an increased risk of being involved in a future violation. Motivated by this, in this paper, we propose a collaborative filtering inspired approach to predicting inappropriate accesses. Our solution integrates both explicit and latent features for staff and patients, the latter acting as a personalized "finger-print" based on historical access patterns. The proposed method, when applied to real EHR access data from two tertiary hospitals and a file-access dataset from Amazon, shows not only significantly improved performance compared to existing methods, but also provides insights as to what indicates an inappropriate access.

  3. Bacterial Infection Potato Tuber Soft Rot Disease Detection Based on Electronic Nose

    Directory of Open Access Journals (Sweden)

    Chang Zhiyong

    2017-11-01

    Full Text Available Soft rot is a severe bacterial disease of potatoes, and soft rot infection can cause significant economic losses during the storage period of potatoes. In this study, potato soft rot was selected as the research object, and a type of potato tuber soft rot disease early detection method based on the electronic nose technology was proposed. An optimized bionic electronic nose gas chamber and a scientific and reasonable sampling device were designed to detect a change in volatile substances of the infected soft rot disease of potato tuber. The infection of soft rot disease in potato tuber samples was detected and identified by using the RBF NN algorithm and SVM algorithm. The results revealed that the proposed bionic electronic nose system can be utilized for early detection of potato tuber soft rot disease. Through comparison and analysis, the recognition rate using the SVM algorithm reached up to 89.7%, and the results were superior to the RBF NN algorithm.

  4. Proceedings of 8. national conference on nuclear electronic and nuclear detection technology: Pt.1

    International Nuclear Information System (INIS)

    1996-01-01

    The 8th National Conference on Nuclear Electronics and Nuclear Detection Technology was held during 2-7, 12, 1996 in Zhuhai, Guangdong, China. 184 pieces of papers were collected in the conference proceedings. The contents of the conference proceedings are: nuclear electronics, nuclear detectors, nuclear instruments and its application, nuclear medical electronics, computer applications in nuclear sciences and technology, measurement of nuclear monitoring and nuclear explosion, radiation hardened electronics, liquid scintillation counting techniques and miscellaneous. Reported hereafter is the first part of the proceedings

  5. Detection of secondary electrons with pixelated hybrid semiconductor detectors; Sekundaerelektronennachweis mit pixelierten hybriden Halbleiterdetektoren

    Energy Technology Data Exchange (ETDEWEB)

    Gebert, Ulrike Sonja

    2011-09-14

    Within the scope of this thesis, secondary electrons were detected with a pixelated semiconductor detector named Timepix. The Timepix detector consists of electronics and a sensor made from a semiconductor material. The connection of sensor and electronics is done for each pixel individually using bump bonds. Electrons with energies above 3 keV can be detected with the sensor. One electron produces a certain amount of electron-hole pairs according to its energy. The charge then drifts along an electric field to the pixel electronics, where it induces an electric signal. Even without a sensor it is possible to detect an electric signal from approximately 1000 electrons directly in the pixel electronics. Two different detector systems to detect secondary electrons using the Timepix detector were investigated during this thesis. First of all, a hybrid photon detector (HPD) was used to detect single photoelectrons. The HPD consists of a vacuum vessel with an entrance window and a cesium iodine photocathode at the inner surface of the window. Photoelectrons are released from the photocathode by incident light and are accelerated in an electric field towards the Timepix detector, where the point of interaction and the arrival time of the electron is determined. With a proximity focusing setup, a time resolution of 12 ns (with an acceleration voltage of 20 kV between photocathode and Timepix detector) was obtained. The HPD examined in this thesis showed a strong dependence of the dark rate form the acceleration voltage and the pressure in the vacuum vessel. At a pressure of few 10{sup -5} mbar and an acceleration voltage of 20 kV, the dark rate was about 800 Hz per mm{sup 2} area of the read out photocathode. One possibility to reduce the dark rate is to identify ion feedback events. With a slightly modified setup it was possible to reduce the dark rate to 0.5 Hz/mm{sup 2}. To achieve this, a new photocathode was mounted in a shorter distance to the detector. The

  6. Depth-selective X-ray absorption spectroscopy by detection of energy-loss Auger electrons

    Energy Technology Data Exchange (ETDEWEB)

    Isomura, Noritake, E-mail: isomura@mosk.tytlabs.co.jp [Toyota Central R& D Labs., Inc., 41-1 Yokomichi, Nagakute, Aichi 480-1192 (Japan); Soejima, Narumasa; Iwasaki, Shiro [Toyota Central R& D Labs., Inc., 41-1 Yokomichi, Nagakute, Aichi 480-1192 (Japan); Nomoto, Toyokazu; Murai, Takaaki [Aichi Synchrotron Radiation Center (AichiSR), 250-3 Minamiyamaguchi-cho, Seto, Aichi 489-0965 (Japan); Kimoto, Yasuji [Toyota Central R& D Labs., Inc., 41-1 Yokomichi, Nagakute, Aichi 480-1192 (Japan)

    2015-11-15

    Graphical abstract: - Highlights: • A unique XAS method is proposed for depth profiling of chemical states. • PEY mode detecting energy-loss electrons enables a variation in the probe depth. • Si K-edge XAS spectra of the Si{sub 3}N{sub 4}/SiO{sub 2}/Si multilayer films have been investigated. • Deeper information was obtained in the spectra measured at larger energy loss. • Probe depth could be changed by the selection of the energy of detected electrons. - Abstract: A unique X-ray absorption spectroscopy (XAS) method is proposed for depth profiling of chemical states in material surfaces. Partial electron yield mode detecting energy-loss Auger electrons, called the inelastic electron yield (IEY) mode, enables a variation in the probe depth. As an example, Si K-edge XAS spectra for a well-defined multilayer sample (Si{sub 3}N{sub 4}/SiO{sub 2}/Si) have been investigated using this method at various kinetic energies. We found that the peaks assigned to the layers from the top layer to the substrate appeared in the spectra in the order of increasing energy loss relative to the Auger electrons. Thus, the probe depth can be changed by the selection of the kinetic energy of the energy loss electrons in IEY-XAS.

  7. Depth-selective X-ray absorption spectroscopy by detection of energy-loss Auger electrons

    International Nuclear Information System (INIS)

    Isomura, Noritake; Soejima, Narumasa; Iwasaki, Shiro; Nomoto, Toyokazu; Murai, Takaaki; Kimoto, Yasuji

    2015-01-01

    Graphical abstract: - Highlights: • A unique XAS method is proposed for depth profiling of chemical states. • PEY mode detecting energy-loss electrons enables a variation in the probe depth. • Si K-edge XAS spectra of the Si_3N_4/SiO_2/Si multilayer films have been investigated. • Deeper information was obtained in the spectra measured at larger energy loss. • Probe depth could be changed by the selection of the energy of detected electrons. - Abstract: A unique X-ray absorption spectroscopy (XAS) method is proposed for depth profiling of chemical states in material surfaces. Partial electron yield mode detecting energy-loss Auger electrons, called the inelastic electron yield (IEY) mode, enables a variation in the probe depth. As an example, Si K-edge XAS spectra for a well-defined multilayer sample (Si_3N_4/SiO_2/Si) have been investigated using this method at various kinetic energies. We found that the peaks assigned to the layers from the top layer to the substrate appeared in the spectra in the order of increasing energy loss relative to the Auger electrons. Thus, the probe depth can be changed by the selection of the kinetic energy of the energy loss electrons in IEY-XAS.

  8. Direct and seamless coupling of TiO{sub 2} nanotube photonic crystal to dye-sensitized solar cell: a single-step approach

    Energy Technology Data Exchange (ETDEWEB)

    Yip, Cho Tung; Zhou, Limin [Department of Mechanical Engineering, Hong Kong Polytechnic University, Hung Hom, Kowloon (China); Huang, Haitao; Xie, Keyu; Wang, Yu. [Department of Applied Physics and Materials Research Center, Hong Kong Polytechnic University, Hung Hom, Kowloon (China); Feng, Tianhua; Li, Jensen [Department of Physics and Materials Science, City University of Hong Kong, Tat Chee Avenue, Kowloon (China); Tam, Wing Yim [Department of Physics, Hong Kong University of Science and Technology, Clear Water Bay, Kowloon (China)

    2011-12-15

    A TiO{sub 2} nanotube layer with a periodic structure is used as a photonic crystal to greatly enhance light harvesting in TiO{sub 2} nanotube-based dye-sensitized solar cells. Such a tube-on-tube structure fabricated by a single-step approach facilitates good physical contact, easy electrolyte infiltration, and efficient charge transport. An increase of over 50% in power conversion efficiency is obtained in comparison to reference cells without a photonic crystal layer (under similar total thickness and dye loading). (Copyright copyright 2011 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  9. Combination of electromembrane extraction and liquid-phase microextraction in a single step: Simultaneous group separation of acidic and basic drugs

    DEFF Research Database (Denmark)

    Huang, Chuixiu; Seip, Knut Fredrik; Gjelstad, Astrid

    2015-01-01

    at high concentration. This approach was further investigated from human plasma. Extraction recoveries were strongly dependent on dilution of plasma with buffer and on extraction time. Finally, this simultaneous EME/LPME approach was evaluated in combination with liquid chromatography (LC......Electromembrane extraction (EME) and liquid-phase microextraction (LPME) were combined in a single step for the first time to realize simultaneous and clear group separation of basic and acidic drugs. Using 2-nitrophenyl octyl ether as the supported liquid membrane (SLM) for EME and dihexyl ether...

  10. Single-step generation of rabbits carrying a targeted allele of the tyrosinase gene using CRISPR/Cas9.

    Science.gov (United States)

    Honda, Arata; Hirose, Michiko; Sankai, Tadashi; Yasmin, Lubna; Yuzawa, Kazuaki; Honsho, Kimiko; Izu, Haruna; Iguchi, Atsushi; Ikawa, Masahito; Ogura, Atsuo

    2015-01-01

    Targeted genome editing of nonrodent mammalian species has provided the potential for highly accurate interventions into gene function in humans and the generation of useful animal models of human diseases. Here we show successful clustered regularly interspaced short palindromic repeat (CRISPR) and CRISPR-associated (Cas)-mediated gene targeting via circular plasmid injection in rabbits. The rabbit tyrosinase gene (TYR) was effectively disrupted, and we confirmed germline transmission by pronuclear injection of a circular plasmid expressing humanized Cas9 (hCas9) and single-guide RNA. Direct injection into pronuclear stage zygotes was possible following an in vitro validation assay. Neither off-target mutagenesis nor hCas9 transgenesis was detected in any of the genetically targeted pups and embryos examined. Gene targeting with this rapid and simplified strategy will help accelerate the development of translational research using other nonrodent mammalian species.

  11. Surfactant-directed synthesis of mesoporous films made single-step by a tandem photosol-gel/photocalcination route

    Energy Technology Data Exchange (ETDEWEB)

    De Paz-Simon, Héloïse; Chemtob, Abraham, E-mail: abraham.chemtob@uha.fr; Croutxé-Barghorn, Céline [Laboratory of Macromolecular Photochemistry and Engineering, ENSCMu, University of Haute-Alsace, 3 bis rue Alfred Werner, 68093 Mulhouse Cedex (France); Rigolet, Séverinne; Michelin, Laure; Vidal, Loïc; Lebeau, Bénédicte [Institut de Science des Matériaux de Mulhouse, UMR-CNRS 7361, University of Haute-Alsace, 3 rue Alfred Werner, 68093 Mulhouse Cedex (France)

    2014-11-01

    In view of their technological impact in materials chemistry, a simplified and more efficient synthetic route to mesoporous films is highly sought. We report, herein, a smart UV-mediated approach coupling in a one-stage process sol-gel photopolymerization and photoinduced template decomposition/ablation to making mesoporous silica films. Performed at room temperature with a solvent-free solution of silicate precursor and amphiphilic poly(ethylene oxide)-poly(propylene oxide)-poly(ethylene oxide) block copolymer, the synthesis relies on photoacid generation to induce the fast formation (≈10 min) of mesostructured silica/surfactant domains. Continuation of UV exposure for three additional hours enables subsequent and complete photodegradation of the polyether copolymer, resulting in ordered or disordered mesoporous silica film. One of the most attractive features is that the one-step procedure relies on a continuous illumination provided by the same conventional medium-pressure Hg-Xe arc lamp equipped with a 254 nm reflector to enhance the emission of energetic photons <300 nm. In addition to X-ray diffraction and transmission electron microscopy, time-resolved Fourier transform infrared spectroscopy has proved to be a powerful in situ technique to probe the different chemical transformations accompanying irradiation. Photocalcination strengthens the inorganic network, while allowing to preserve a higher fraction of residual silanol groups compared with thermal calcination. A polyether chain degradation mechanism based on oxygen reactive species-mediated photo-oxidation is proposed.

  12. Microchannel-connected SU-8 honeycombs by single-step projection photolithography for positioning cells on silicon oxide nanopillar arrays

    International Nuclear Information System (INIS)

    Larramendy, Florian; Paul, Oliver; Blatche, Marie Charline; Mazenq, Laurent; Laborde, Adrian; Temple-Boyer, Pierre

    2015-01-01

    We report on the fabrication, functionalization and testing of SU-8 microstructures for cell culture and positioning over large areas. The microstructure consists of a honeycomb arrangement of cell containers interconnected by microchannels and centered on nanopillar arrays designed for promoting cell positioning. The containers have been dimensioned to trap single cells and, with a height of 50 µm, prevent cells from escaping. The structures are fabricated using a single ultraviolet photolithography exposure with focus depth in the lower part of the SU-8 resist. With optimized process parameters, microchannels of various aspect ratios are thus produced. The cell containers and microchannels serve for the organization of axonal growth between neurons. The roughly 2 µm-high and 500 nm-wide nanopillars are made of silicon oxide structured by deep reactive ion etching. In future work, beyond their cell positioning purpose, the nanopillars could be functionalized as sensors. The proof of concept of the novel microstructure for organized cell culture is given by the successful growth of interconnected PC12 cells. Promoted by the honeycomb geometry, a dense network of interconnections between the cells has formed and the intended intimate contact of cells with the nanopillar arrays was observed by scanning electron microscopy. This proves the potential of these new devices as tools for the controlled cell growth in an interconnected container system with well-defined 3D geometry. (paper)

  13. A method to detect ultra high energy electrons using earth's magnetic field as a radiator

    Science.gov (United States)

    Stephens, S. A.; Balasubrahmanyan, V. K.

    1983-01-01

    It is pointed out that the detection of electrons with energies exceeding a few TeV, which lose energy rapidly through synchrotron and inverse Compton processes, would provide valuable information on the distribution of sources and on the propagation of cosmic rays in the solar neighborhood. However, it would not be possible to measure the energy spectrum beyond a few TeV with any of the existing experimental techniques. The present investigation is, therefore concerned with the possibility of detecting electrons with energies exceeding a few TeV on the basis of the photons emitted through synchrotron radiation in the earth's magnetic field. Attention is given to the synchrotron radiation of electrons in the earth's magnetic field, detector response and energy estimation, and the characteristics of an ideal detector, capable of detecting photons with energies equal to or greater than 20 keV.

  14. Electrically-detected electron paramagnetic resonance of point centers in 6H-SiC nanostructures

    Czech Academy of Sciences Publication Activity Database

    Bagraev, N.T.; Gets, D.S.; Kalabukhova, E.N.; Klyachkin, L.E.; Malyarenko, A.M.; Mashkov, V.A.; Savchenko, Dariia; Shanina, B.D.

    2014-01-01

    Roč. 48, č. 11 (2014), s. 1467-1480 ISSN 1063-7826 R&D Projects: GA MŠk(CZ) LM2011029 Grant - others:SAFMAT(XE) CZ.2.16/3.1.00/22132 Institutional support: RVO:68378271 Keywords : electron paramagnetic resonance * electrically- detected electron paramagnetic resonance * 6H -SiC nanostructures * nitrogen-vacancy defect * point defect Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 0.739, year: 2014

  15. Detection of water and its derivatives on individual nanoparticles using vibrational electron energy-loss spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Crozier, Peter A., E-mail: crozier@asu.edu [School for the Engineering of Matter, Transport and Energy, Arizona State University, 501 E. Tyler Mall, Tempe, AZ 85287-6106 (United States); Aoki, Toshihiro [LeRoy Eyring Center for Solid State Science, Arizona State University, Tempe, AZ 85287-1704 (United States); Liu, Qianlang [School for the Engineering of Matter, Transport and Energy, Arizona State University, 501 E. Tyler Mall, Tempe, AZ 85287-6106 (United States)

    2016-10-15

    Understanding the role of water, hydrate and hydroxyl species on nanoparticle surfaces and interfaces is very important in both physical and life sciences. Detecting the presence of oxygen-hydrogen species with nanometer resolution is extremely challenging at present. Here we show that the recently developed vibrational electron energy-loss spectroscopy using subnanometer focused electron beams can be employed to spectroscopically identify the local presence and variation of OH species on nanoscale surfaces. The hydrogen-oxygen fingerprint can be correlated with highly localized structural and morphological information obtained from electron imaging. Moreover, the current approach exploits the aloof beam mode of spectral acquisition which does not require direct electron irradiation of the sample thus greatly reducing beam damage to the OH bond. These findings open the door for using electron microscopy to probe local hydroxyl and hydrate species on nanoscale organic and inorganic structures. - Highlights: • High spatial resolution spectroscopic detection of water related species in nanoparticles. • Detection of OH stretch modes with vibrational EELS. • Differentiation between hydrate and hydroxide species on or on nanoparticles. • Detection of hydrate on a single 60 nm oxide nanoparticle of MgO. • Use of aloof beam EELS to minimize radiation damage.

  16. Performance of a direct detection camera for off-axis electron holography

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Shery L.Y., E-mail: shery.chang@asu.edu [Ernst Ruska-Centre for Microscopy and Spectroscopy with Electrons, and Peter Grünberg Institute, Forschungszentrum Jülich, D-52425 Jülich (Germany); LeRoy Eyring Center for Solid State Science, Arizona State University, Tempe, AZ 85287 (United States); Dwyer, Christian [Ernst Ruska-Centre for Microscopy and Spectroscopy with Electrons, and Peter Grünberg Institute, Forschungszentrum Jülich, D-52425 Jülich (Germany); Department of Physics, Arizona State University, Tempe, AZ 85287 (United States); Barthel, Juri; Boothroyd, Chris B.; Dunin-Borkowski, Rafal E. [Ernst Ruska-Centre for Microscopy and Spectroscopy with Electrons, and Peter Grünberg Institute, Forschungszentrum Jülich, D-52425 Jülich (Germany)

    2016-02-15

    The performance of a direct detection camera (DDC) is evaluated in the context of off-axis electron holographic experiments in a transmission electron microscope. Its performance is also compared directly with that of a conventional charge-coupled device (CCD) camera. The DDC evaluated here can be operated either by the detection of individual electron events (counting mode) or by the effective integration of many such events during a given exposure time (linear mode). It is demonstrated that the improved modulation transfer functions and detective quantum efficiencies of both modes of the DDC give rise to significant benefits over the conventional CCD cameras, specifically, a significant improvement in the visibility of the holographic fringes and a reduction of the statistical error in the phase of the reconstructed electron wave function. The DDC's linear mode, which can handle higher dose rates, allows optimisation of the dose rate to achieve the best phase resolution for a wide variety of experimental conditions. For suitable conditions, the counting mode can potentially utilise a significantly lower dose to achieve a phase resolution that is comparable to that achieved using the linear mode. The use of multiple holograms and correlation techniques to increase the total dose in counting mode is also demonstrated. - Highlights: • Performance of a direct detection camera for off-axis electron holography has been evaluated. • Better holographic fringe visibility and phase resolution are achieved using DDC. • Both counting and linear modes offered by DDC are advantageous for different dose regimes.

  17. Performance of a direct detection camera for off-axis electron holography

    International Nuclear Information System (INIS)

    Chang, Shery L.Y.; Dwyer, Christian; Barthel, Juri; Boothroyd, Chris B.; Dunin-Borkowski, Rafal E.

    2016-01-01

    The performance of a direct detection camera (DDC) is evaluated in the context of off-axis electron holographic experiments in a transmission electron microscope. Its performance is also compared directly with that of a conventional charge-coupled device (CCD) camera. The DDC evaluated here can be operated either by the detection of individual electron events (counting mode) or by the effective integration of many such events during a given exposure time (linear mode). It is demonstrated that the improved modulation transfer functions and detective quantum efficiencies of both modes of the DDC give rise to significant benefits over the conventional CCD cameras, specifically, a significant improvement in the visibility of the holographic fringes and a reduction of the statistical error in the phase of the reconstructed electron wave function. The DDC's linear mode, which can handle higher dose rates, allows optimisation of the dose rate to achieve the best phase resolution for a wide variety of experimental conditions. For suitable conditions, the counting mode can potentially utilise a significantly lower dose to achieve a phase resolution that is comparable to that achieved using the linear mode. The use of multiple holograms and correlation techniques to increase the total dose in counting mode is also demonstrated. - Highlights: • Performance of a direct detection camera for off-axis electron holography has been evaluated. • Better holographic fringe visibility and phase resolution are achieved using DDC. • Both counting and linear modes offered by DDC are advantageous for different dose regimes.

  18. High resolution surface scanning of Thick-GEM for single photo-electron detection

    International Nuclear Information System (INIS)

    Hamar, G.; Varga, D.

    2012-01-01

    An optical system for high resolution scanning of TGEM UV photon detection systems is introduced. The structure exploits the combination of a single Au-coated TGEM under study, and an asymmetric MWPC (Close Cathode Chamber) as post-amplification stage. A pulsed UV LED source with emission down to 240 nm has been focused to a spot of 0.07 mm on the TGEM surface, and single photo-electron charge spectra has been recorded over selected two dimensional regions. This way, the TGEM gain (order of 10–100) and TGEM photo-electron detection efficiency is clearly separated, unlike in case of continuous illumination. The surface structure connected to the TGEM photon detection is well observable, including inefficiencies in the holes and at the symmetry points between holes. The detection efficiency as well as the gas gain are fluctuating from hole to hole. The gain is constant in the hexagon around any hole, pointing to the fact that the gain depends on hole geometry, and less on the position where the electron enters. The detection probability map strongly changes with the field strength above the TGEM surface, in relation to the change of the actual surface field configuration. The results can be confronted with position-dependent simulations of TGEM electron transfer and gas multiplication. -- Highlights: ► First demonstration of Thick GEM surface scanning with single photo-electrons. ► Resolution of 0.1 mm is sufficient to identify structures connected to TGEM surface field structure. ► Gain and detection efficiency and separately measurable. ► Detection efficiency is high in a ring around the holes, and gain is constant in the hexagonal collection regions.

  19. High resolution surface scanning of Thick-GEM for single photo-electron detection

    Energy Technology Data Exchange (ETDEWEB)

    Hamar, G., E-mail: hamar.gergo@wigner.mta.hu [Wigner Research Centre for Physics, Budapest (Hungary); Varga, D., E-mail: vdezso@mail.cern.ch [Eoetvoes Lorand University, Budapest (Hungary)

    2012-12-01

    An optical system for high resolution scanning of TGEM UV photon detection systems is introduced. The structure exploits the combination of a single Au-coated TGEM under study, and an asymmetric MWPC (Close Cathode Chamber) as post-amplification stage. A pulsed UV LED source with emission down to 240 nm has been focused to a spot of 0.07 mm on the TGEM surface, and single photo-electron charge spectra has been recorded over selected two dimensional regions. This way, the TGEM gain (order of 10-100) and TGEM photo-electron detection efficiency is clearly separated, unlike in case of continuous illumination. The surface structure connected to the TGEM photon detection is well observable, including inefficiencies in the holes and at the symmetry points between holes. The detection efficiency as well as the gas gain are fluctuating from hole to hole. The gain is constant in the hexagon around any hole, pointing to the fact that the gain depends on hole geometry, and less on the position where the electron enters. The detection probability map strongly changes with the field strength above the TGEM surface, in relation to the change of the actual surface field configuration. The results can be confronted with position-dependent simulations of TGEM electron transfer and gas multiplication. -- Highlights: Black-Right-Pointing-Pointer First demonstration of Thick GEM surface scanning with single photo-electrons. Black-Right-Pointing-Pointer Resolution of 0.1 mm is sufficient to identify structures connected to TGEM surface field structure. Black-Right-Pointing-Pointer Gain and detection efficiency and separately measurable. Black-Right-Pointing-Pointer Detection efficiency is high in a ring around the holes, and gain is constant in the hexagonal collection regions.

  20. Development of a method to extract and purify target compounds from medicinal plants in a single step: online hyphenation of expanded bed adsorption chromatography and countercurrent chromatography.

    Science.gov (United States)

    Li, Yang; Wang, Nan; Zhang, Min; Ito, Yoichiro; Zhang, Hongyang; Wang, Yuerong; Guo, Xin; Hu, Ping

    2014-04-01

    Pure compounds extracted and purified from natural sources are crucial to lead discovery and drug screening. This study presents a novel two-dimensional hyphenation of expanded bed adsorption chromatography (EBAC) and high-speed countercurrent chromatography (HSCCC) for extraction and purification of target compounds from medicinal plants in a single step. The EBAC and HSCCC were hyphenated via a six-port injection valve as an interface. Fractionation of ingredients of Salvia miltiorrhiza and Rhizoma coptidis was performed on the hyphenated system to verify its efficacy. Two compounds were harvested from Salvia miltiorrhiza, one was 52.9 mg of salvianolic acid B with an over 95% purity and the other was 2.1 mg of rosmarinic acid with a 74% purity. Another two components were purified from Rhizoma coptidis, one was 4.6 mg of coptisine with a 98% purity and one was 4.1 mg of berberine with a 82% purity. The processing time was nearly 50% that of the multistep method. The results indicate that the present method is a rapid and green way to harvest targets from medicinal plants in a single step.

  1. A novel single-step procedure for the calibration of the mounting parameters of a multi-camera terrestrial mobile mapping system

    Science.gov (United States)

    Habib, A.; Kersting, P.; Bang, K.; Rau, J.

    2011-12-01

    Mobile Mapping Systems (MMS) can be defined as moving platforms which integrates a set of imaging sensors and a position and orientation system (POS) for the collection of geo-spatial information. In order to fully explore the potential accuracy of such systems and guarantee accurate multi-sensor integration, a careful system calibration must be carried out. System calibration involves individual sensor calibration as well as the estimation of the inter-sensor geometric relationship. This paper tackles a specific component of the system calibration process of a multi-camera MMS - the estimation of the relative orientation parameters among the cameras, i.e., the inter-camera geometric relationship (lever-arm offsets and boresight angles among the cameras). For that purpose, a novel single step procedure, which is easy to implement and not computationally intensive, will be introduced. The proposed method is implemented in such a way that it can also be used for the estimation of the mounting parameters among the cameras and the IMU body frame, in case of directly georeferenced systems. The performance of the proposed method is evaluated through experimental results using simulated data. A comparative analysis between the proposed single-step and the two-step, which makes use of the traditional bundle adjustment procedure, is demonstrated.

  2. Single-step syngas-to-distillates (S2D) process based on biomass-derived syngas--a techno-economic analysis.

    Science.gov (United States)

    Zhu, Yunhua; Jones, Susanne B; Biddy, Mary J; Dagle, Robert A; Palo, Daniel R

    2012-08-01

    This study compared biomass gasification based syngas-to-distillate (S2D) systems using techno-economic analysis (TEA). Three cases, state of technology (SOT), goal, and conventional, were compared in terms of performance and cost. The SOT case represented the best available experimental results for a process starting with syngas using a single-step dual-catalyst reactor for distillate generation. The conventional case mirrored a conventional two-step S2D process consisting of separate syngas-to-methanol and methanol-to-gasoline (MTG) processes. The goal case assumed the same performance as the conventional, but with a single-step S2D technology. TEA results revealed that the SOT was more expensive than the conventional and goal cases. The SOT case suffers from low one-pass yield and high selectivity to light hydrocarbons, both of which drive up production cost. Sensitivity analysis indicated that light hydrocarbon yield and single pass conversion efficiency were the key factors driving the high cost for the SOT case. Copyright © 2012 Elsevier Ltd. All rights reserved.

  3. Single-step uncalcined N-TiO{sub 2} synthesis, characterizations and its applications on alachlor photocatalytic degradations

    Energy Technology Data Exchange (ETDEWEB)

    Suwannaruang, Totsaporn, E-mail: totsaporn.eng.kku@gmail.com [Department of Chemical Engineering, Faculty of Engineering, Khon Kaen University, Khon Kaen 40002 (Thailand); Chemical Kinetics and Applied Catalysis Laboratory (CKCL), Faculty of Engineering, Khon Kaen University, Khon Kaen 40002 (Thailand); Wantala, Kitirote, E-mail: kitirote@kku.ac.th [Department of Chemical Engineering, Faculty of Engineering, Khon Kaen University, Khon Kaen 40002 (Thailand); Chemical Kinetics and Applied Catalysis Laboratory (CKCL), Faculty of Engineering, Khon Kaen University, Khon Kaen 40002 (Thailand); Research Center for Environmental and Hazardous Substance Management (EHSM), Faculty of Engineering, Khon Kaen University, Khon Kaen 40002 (Thailand)

    2016-09-01

    Graphical abstract: - Highlights: • N-TiO{sub 2} can be synthesized on one crystal in one particle. • Surface area has been relating to performance of photocatalysts. • Energy band-gap of N-TiO{sub 2} show lower than 3.0 eV. - Abstract: The aims of this research were to synthesize nitrogen doped TiO{sub 2} (N-TiO{sub 2}) photocatalysts produced by hydrothermal technique and to test the degradation performance of alachlor by photocatalytic process under UV irradiations in the effect of aging temperature and time in the preparation process. The characterizations of synthesized TiO{sub 2} such as specific surface area, particle size, phase structure and elements were analyzed by using the Brunauer–Emmett–Teller (BET) technique, Transmission Electron Microscopy (TEM), X-ray Diffractometer (XRD) and Energy Dispersive X-ray spectrometer (EDX), respectively. The Central Composite Design (CCD) was used to design the experiment to determine the optimal condition, main effects and their interactions by using specific surface area, percent alachlor removal and observed first-order rate constant as responses. The kinetic reactions of alachlor degradation were explained by using Langmuir-Hinshelwood expression to confirm the reaction took place on the surface of photocatalyst. The results showed that the effect of aging temperatures was significant on surface area, whereas aging time was insignificant. Additionally, the square term of aging temperature and interaction term were shown significant on the specific surface area as well. The highest specific surface area from response surface at aging temperature between 150–175 °C and aging time between 6–13 h was found in a range of 100–106 m{sup 2}/g. The average particle size of TiO{sub 2} was similar to crystallite size. Therefore, it can be concluded that one particle has only one crystal. The element analysis has shown 10% of nitrogen in TiO{sub 2} structure that the energy band-gap about 2.95 eV was found

  4. First Detection of Low Energy Electron Neutrinos in Liquid Argon Time Projection Chambers

    Energy Technology Data Exchange (ETDEWEB)

    Adams, Corey James [Yale U.

    2016-01-01

    Electron neutrino appearance is the signature channel to address the most pressing questions in neutrino oscillations physics, at both long and short baselines. This includes the search for CP violation in the neutrino sector, which the U.S. flagship neutrino experiment DUNE will address. In addition, the Short Baseline Neutrino Program at Fermilab (MicroBooNE, SBND, ICARUS-T600) searches for new physics, such as sterile neutrinos, through electron neutrino appearance. Liquid argon time projection chambers are the forefront of neutrino detection technology, and the detector of choice for both short and long baseline neutrino oscillation experiments. This work presents the first experimental observation and study of electron neutrinos in the 1-10 GeV range, the essential oscillation energy regime for the above experiments. The systematic uncertainties for an electron neutrino appearance search for the Fermilab Short Baseline Neutrino Program are carefully quantified, and the characterization of separation between electrons and high energy photons is examined.

  5. Review of electronic-nose technologies and algorithms to detect hazardous chemicals in the environment

    Science.gov (United States)

    Alphus D. Wilson

    2012-01-01

    Novel mobile electronic-nose (e-nose) devices and algorithms capable of real-time detection of industrial and municipal pollutants, released from point-sources, recently have been developed by scientists worldwide that are useful for monitoring specific environmental-pollutant levels for enforcement and implementation of effective pollution-abatement programs. E-nose...

  6. An electronic apparatus for early detection of changes in red cell ...

    African Journals Online (AJOL)

    An electronic apparatus was developed for anaesthetists to use to detect changes in red cell concentration during surgery. The mechanism is based on the relationship between the red cell content and the electrical conductivity of blood. In a pilot study of 170 blood samples, a correlation coefficient of 0,9806 was obtained ...

  7. An electronic apparatus for early detection of changes in red cell ...

    African Journals Online (AJOL)

    1989-08-19

    Aug 19, 1989 ... An electronic apparatus was developed for anaesthetists to use to detect changes in red cell concentration during sur- gery. The mechanism is based on the relationship between the red cell content and the electrical conductivity of blood. In a pilot study of 170 blood samples, a correlation coefficient.

  8. Acetic Acid Detection Threshold in Synthetic Wine Samples of a Portable Electronic Nose

    Directory of Open Access Journals (Sweden)

    Miguel Macías Macías

    2012-12-01

    Full Text Available Wine quality is related to its intrinsic visual, taste, or aroma characteristics and is reflected in the price paid for that wine. One of the most important wine faults is the excessive concentration of acetic acid which can cause a wine to take on vinegar aromas and reduce its varietal character. Thereby it is very important for the wine industry to have methods, like electronic noses, for real-time monitoring the excessive concentration of acetic acid in wines. However, aroma characterization of alcoholic beverages with sensor array electronic noses is a difficult challenge due to the masking effect of ethanol. In this work, in order to detect the presence of acetic acid in synthetic wine samples (aqueous ethanol solution at 10% v/v we use a detection unit which consists of a commercial electronic nose and a HSS32 auto sampler, in combination with a neural network classifier (MLP. To find the characteristic vector representative of the sample that we want to classify, first we select the sensors, and the section of the sensors response curves, where the probability of detecting the presence of acetic acid will be higher, and then we apply Principal Component Analysis (PCA such that each sensor response curve is represented by the coefficients of its first principal components. Results show that the PEN3 electronic nose is able to detect and discriminate wine samples doped with acetic acid in concentrations equal or greater than 2 g/L.

  9. Implementation of genomic recursions in single-step genomic best linear unbiased predictor for US Holsteins with a large number of genotyped animals.

    Science.gov (United States)

    Masuda, Y; Misztal, I; Tsuruta, S; Legarra, A; Aguilar, I; Lourenco, D A L; Fragomeni, B O; Lawlor, T J

    2016-03-01

    The objectives of this study were to develop and evaluate an efficient implementation in the computation of the inverse of genomic relationship matrix with the recursion algorithm, called the algorithm for proven and young (APY), in single-step genomic BLUP. We validated genomic predictions for young bulls with more than 500,000 genotyped animals in final score for US Holsteins. Phenotypic data included 11,626,576 final scores on 7,093,380 US Holstein cows, and genotypes were available for 569,404 animals. Daughter deviations for young bulls with no classified daughters in 2009, but at least 30 classified daughters in 2014 were computed using all the phenotypic data. Genomic predictions for the same bulls were calculated with single-step genomic BLUP using phenotypes up to 2009. We calculated the inverse of the genomic relationship matrix GAPY(-1) based on a direct inversion of genomic relationship matrix on a small subset of genotyped animals (core animals) and extended that information to noncore animals by recursion. We tested several sets of core animals including 9,406 bulls with at least 1 classified daughter, 9,406 bulls and 1,052 classified dams of bulls, 9,406 bulls and 7,422 classified cows, and random samples of 5,000 to 30,000 animals. Validation reliability was assessed by the coefficient of determination from regression of daughter deviation on genomic predictions for the predicted young bulls. The reliabilities were 0.39 with 5,000 randomly chosen core animals, 0.45 with the 9,406 bulls, and 7,422 cows as core animals, and 0.44 with the remaining sets. With phenotypes truncated in 2009 and the preconditioned conjugate gradient to solve mixed model equations, the number of rounds to convergence for core animals defined by bulls was 1,343; defined by bulls and cows, 2,066; and defined by 10,000 random animals, at most 1,629. With complete phenotype data, the number of rounds decreased to 858, 1,299, and at most 1,092, respectively. Setting up GAPY(-1

  10. A condensed matter electron momentum spectrometer with parallel detection in energy and momentum

    Energy Technology Data Exchange (ETDEWEB)

    Storer, P; Caprari, R S; Clark, S A.C.; Vos, M; Weigold, E

    1994-03-01

    An electron momentum spectrometer has been constructed which measures electron binding energies and momenta by fully determining the kinematics of the incident, scattered and ejected electrons resulting from (e,2e) ionizing collisions in a thin solid foil. The spectrometer operates with incident beam energies of 20-30 keV in an asymmetric, non-coplanar scattering geometry. Bethe ridge kinematics are used. The technique uses transmission through the target foil, but it is most sensitive to the surface from which the 1.2 keV electrons emerge, to a depth of about 5 nm. Scattered and ejected electron energies and azimuthal angles are detected in parallel using position sensitive detection, yielding true coincidence count rates of 6 Hz from a 5.5 nm thick evaporated carbon target and an incident beam current of around 100 nA. The energy resolution is approximately 1.3 eV and momentum resolution approximately 0.15 a{sub 0}{sup -1}. The energy resolution could readily be improved by monochromating the incident electron beam. 28 refs., 15 figs.

  11. A condensed matter electron momentum spectrometer with parallel detection in energy and momentum

    International Nuclear Information System (INIS)

    Storer, P.; Caprari, R.S.; Clark, S.A.C.; Vos, M.; Weigold, E.

    1994-03-01

    An electron momentum spectrometer has been constructed which measures electron binding energies and momenta by fully determining the kinematics of the incident, scattered and ejected electrons resulting from (e,2e) ionizing collisions in a thin solid foil. The spectrometer operates with incident beam energies of 20-30 keV in an asymmetric, non-coplanar scattering geometry. Bethe ridge kinematics are used. The technique uses transmission through the target foil, but it is most sensitive to the surface from which the 1.2 keV electrons emerge, to a depth of about 5 nm. Scattered and ejected electron energies and azimuthal angles are detected in parallel using position sensitive detection, yielding true coincidence count rates of 6 Hz from a 5.5 nm thick evaporated carbon target and an incident beam current of around 100 nA. The energy resolution is approximately 1.3 eV and momentum resolution approximately 0.15 a 0 -1 . The energy resolution could readily be improved by monochromating the incident electron beam. 28 refs., 15 figs

  12. Nano-Electromechanical Systems: Displacement Detection and the Mechanical Single Electron Shuttle

    Science.gov (United States)

    Blick, R. H.; Beil, F. W.; Höhberger, E.; Erbe, A.; Weiss, C.

    For an introduction to nano-electromechanical systems we present measurements on nanomechanical resonators operating in the radio frequency range. We discuss in detail two different schemes of displacement detection for mechanical resonators, namely conventional reflection measurements of a probing signal and direct detection by capacitive coupling via a gate electrode. For capacitive detection we employ an on-chip preamplifier, which enables direct measurements of the resonator's disp lacement. We observe that the mechanical quality factor of the resonator depends on the detection technique applied, which is verified in model calculations and report on the detection of sub-harmonics. In the second part we extend our investigations to include transport of single electrons through an electron island on the tip of a nanomachined mechanical pendulum. The pendulum is operated by applying a modulating electromagnetic field in the range of 1 - 200 MHz, leading to mechanical oscillations between two laterally integrated source and drain contacts. Forming tunneling barriers the metallic tip shuttles single electrons from source to drain. The resulting tunneling current shows distinct features corresponding to the discrete mechanical eigenfrequencies of the pendulum. We report on measurements covering the temperature range from 300 K down to 4.2 K. The transport properties of the device are compared in detail to model calculations based on a Master-equation approach.

  13. Continuous wave protocol for simultaneous polarization and optical detection of P1-center electron spin resonance

    Science.gov (United States)

    Kamp, E. J.; Carvajal, B.; Samarth, N.

    2018-01-01

    The ready optical detection and manipulation of bright nitrogen vacancy center spins in diamond plays a key role in contemporary quantum information science and quantum metrology. Other optically dark defects such as substitutional nitrogen atoms (`P1 centers') could also become potentially useful in this context if they could be as easily optically detected and manipulated. We develop a relatively straightforward continuous wave protocol that takes advantage of the dipolar coupling between nitrogen vacancy and P1 centers in type 1b diamond to detect and polarize the dark P1 spins. By combining mutual spin flip transitions with radio frequency driving, we demonstrate the simultaneous optical polarization and detection of the electron spin resonance of the P1 center. This technique should be applicable to detecting and manipulating a broad range of dark spin populations that couple to the nitrogen vacancy center via dipolar fields, allowing for quantum metrology using these spin populations.

  14. Botulinum toxin detection using AlGaN /GaN high electron mobility transistors

    Science.gov (United States)

    Wang, Yu-Lin; Chu, B. H.; Chen, K. H.; Chang, C. Y.; Lele, T. P.; Tseng, Y.; Pearton, S. J.; Ramage, J.; Hooten, D.; Dabiran, A.; Chow, P. P.; Ren, F.

    2008-12-01

    Antibody-functionalized, Au-gated AlGaN /GaN high electron mobility transistors (HEMTs) were used to detect botulinum toxin. The antibody was anchored to the gate area through immobilized thioglycolic acid. The AlGaN /GaN HEMT drain-source current showed a rapid response of less than 5s when the target toxin in a buffer was added to the antibody-immobilized surface. We could detect a range of concentrations from 1to10ng/ml. These results clearly demonstrate the promise of field-deployable electronic biological sensors based on AlGaN /GaN HEMTs for botulinum toxin detection.

  15. High speed preamplifier circuit, detection electronics, and radiation detection systems therefrom

    Science.gov (United States)

    Riedel, Richard A [Knoxville, TN; Wintenberg, Alan L [Knoxville, TN; Clonts, Lloyd G [Knoxville, TN; Cooper, Ronald G [Oak Ridge, TN

    2010-09-21

    A preamplifier circuit for processing a signal provided by a radiation detector includes a transimpedance amplifier coupled to receive a current signal from a detector and generate a voltage signal at its output. A second amplification stage has an input coupled to an output of the transimpedance amplifier for providing an amplified voltage signal. Detector electronics include a preamplifier circuit having a first and second transimpedance amplifier coupled to receive a current signal from a first and second location on a detector, respectively, and generate a first and second voltage signal at respective outputs. A second amplification stage has an input coupled to an output of the transimpedance amplifiers for amplifying the first and said second voltage signals to provide first and second amplified voltage signals. A differential output stage is coupled to the second amplification stage for receiving the first and second amplified voltage signals and providing a pair of outputs from each of the first and second amplified voltage signals. Read out circuitry has an input coupled to receive both of the pair of outputs, the read out circuitry having structure for processing each of the pair of outputs, and providing a single digital output having a time-stamp therefrom.

  16. Electron Signal Detection for the Beam-Finder Wire of the Linac Coherent Light Source Undulator

    International Nuclear Information System (INIS)

    Wu, Juhao; Emma, P.; Field, R.C.; SLAC

    2006-01-01

    The Linac Coherent Light Source (LCLS) is a SASE x-ray Free-Electron Laser (FEL) based on the final kilometer of the Stanford Linear Accelerator. The tight tolerances for positioning the electron beam close to the undulator axis calls for the introduction of Beam Finder Wire (BFW) device. A BFW device close to the upstream end of the undulator segment and a quadrupole close to the down stream end of the undulator segment will allow a beam-based undulator segment alignment. Based on the scattering of the electrons on the BFW, we can detect the electron signal in the main dump bends after the undulator to find the beam position. We propose to use a threshold Cherenkov counter for this purpose. According to the signal strength at such a Cherenkov counter, we then suggest choice of material and size for such a BFW device in the undulator

  17. GAGG:ce single crystalline films: New perspective scintillators for electron detection in SEM.

    Science.gov (United States)

    Bok, Jan; Lalinský, Ondřej; Hanuš, Martin; Onderišinová, Zuzana; Kelar, Jakub; Kučera, Miroslav

    2016-04-01

    Single crystal scintillators are frequently used for electron detection in scanning electron microscopy (SEM). We report gadolinium aluminum gallium garnet (GAGG:Ce) single crystalline films as a new perspective scintillators for the SEM. For the first time, the epitaxial garnet films were used in a practical application: the GAGG:Ce scintillator was incorporated into a SEM scintillation electron detector and it showed improved image quality. In order to prove the GAGG:Ce quality accurately, the scintillation properties were examined using electron beam excitation and compared with frequently used scintillators in the SEM. The results demonstrate excellent emission efficiency of the GAGG:Ce single crystalline films together with their very fast scintillation decay useful for demanding SEM applications. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. GAGG:ce single crystalline films: New perspective scintillators for electron detection in SEM

    International Nuclear Information System (INIS)

    Bok, Jan; Lalinský, Ondřej; Hanuš, Martin; Onderišinová, Zuzana; Kelar, Jakub; Kučera, Miroslav

    2016-01-01

    Single crystal scintillators are frequently used for electron detection in scanning electron microscopy (SEM). We report gadolinium aluminum gallium garnet (GAGG:Ce) single crystalline films as a new perspective scintillators for the SEM. For the first time, the epitaxial garnet films were used in a practical application: the GAGG:Ce scintillator was incorporated into a SEM scintillation electron detector and it showed improved image quality. In order to prove the GAGG:Ce quality accurately, the scintillation properties were examined using electron beam excitation and compared with frequently used scintillators in the SEM. The results demonstrate excellent emission efficiency of the GAGG:Ce single crystalline films together with their very fast scintillation decay useful for demanding SEM applications. - Highlights: • First practical application of epitaxial garnet films demonstrated in SEM. • Improved image quality of SEM equipped with GAGG:Ce single crystalline thin film scintillator. • Scintillation properties of GAGG:Ce films compared with standard bulk crystal scintillators.

  19. Detection of single electron spin resonance in a double quantum dota)

    Science.gov (United States)

    Koppens, F. H. L.; Buizert, C.; Vink, I. T.; Nowack, K. C.; Meunier, T.; Kouwenhoven, L. P.; Vandersypen, L. M. K.

    2007-04-01

    Spin-dependent transport measurements through a double quantum dot are a valuable tool for detecting both the coherent evolution of the spin state of a single electron, as well as the hybridization of two-electron spin states. In this article, we discuss a model that describes the transport cycle in this regime, including the effects of an oscillating magnetic field (causing electron spin resonance) and the effective nuclear fields on the spin states in the two dots. We numerically calculate the current flow due to the induced spin flips via electron spin resonance, and we study the detector efficiency for a range of parameters. The experimental data are compared with the model and we find a reasonable agreement.

  20. Single-Step Electrophoretic Deposition of Non-noble Metal Catalyst Layer with Low Onset Voltage for Ethanol Electro-oxidation.

    Science.gov (United States)

    Ahmadi Daryakenari, Ahmad; Hosseini, Davood; Ho, Ya-Lun; Saito, Takumi; Apostoluk, Aleksandra; Müller, Christoph R; Delaunay, Jean-Jacques

    2016-06-29

    A single-step electrophoretic deposition (EPD) process is used to fabricate catalyst layers which consist of nickel oxide nanoparticles attached on the surface of nanographitic flakes. Magnesium ions present in the colloid charge positively the flake's surface as they attach on it and are also used to bind nanographitic flakes together. The fabricated catalyst layers showed a very low onset voltage (-0.2 V vs Ag/AgCl) in the electro-oxidation of ethanol. To clarify the occurring catalytic mechanism, we performed annealing treatment to produce samples having a different electrochemical behavior with a large onset voltage. Temperature dependence measurements of the layer conductivity pointed toward a charge transport mechanism based on hopping for the nonannealed layers, while the drift transport is observed in the annealed layers. The hopping charge transport is responsible for the appearance of the low onset voltage in ethanol electro-oxidation.

  1. Improving genetic evaluation of litter size and piglet mortality for both genotyped and nongenotyped individuals using a single-step method.

    Science.gov (United States)

    Guo, X; Christensen, O F; Ostersen, T; Wang, Y; Lund, M S; Su, G

    2015-02-01

    A single-step method allows genetic evaluation using information of phenotypes, pedigree, and markers from genotyped and nongenotyped individuals simultaneously. This paper compared genomic predictions obtained from a single-step BLUP (SSBLUP) method, a genomic BLUP (GBLUP) method, a selection index blending (SELIND) method, and a traditional pedigree-based method (BLUP) for total number of piglets born (TNB), litter size at d 5 after birth (LS5), and mortality rate before d 5 (Mort; including stillbirth) in Danish Landrace and Yorkshire pigs. Data sets of 778,095 litters from 309,362 Landrace sows and 472,001 litters from 190,760 Yorkshire sows were used for the analysis. There were 332,795 Landrace and 207,255 Yorkshire animals in the pedigree data, among which 3,445 Landrace pigs (1,366 boars and 2,079 sows) and 3,372 Yorkshire pigs (1,241 boars and 2,131 sows) were genotyped with the Illumina PorcineSNP60 BeadChip. The results showed that the 3 methods with marker information (SSBLUP, GBLUP, and SELIND) produced more accurate predictions for genotyped animals than the pedigree-based method. For genotyped animals, the average of reliabilities for all traits in both breeds using traditional BLUP was 0.091, which increased to 0.171 w+hen using GBLUP and to 0.179 when using SELIND and further increased to 0.209 when using SSBLUP. Furthermore, the average reliability of EBV for nongenotyped animals was increased from 0.091 for traditional BLUP to 0.105 for the SSBLUP. The results indicate that the SSBLUP is a good approach to practical genomic prediction of litter size and piglet mortality in Danish Landrace and Yorkshire populations.

  2. Induction-detection electron spin resonance with spin sensitivity of a few tens of spins

    Energy Technology Data Exchange (ETDEWEB)

    Artzi, Yaron; Twig, Ygal; Blank, Aharon [Schulich Faculty of Chemistry Technion—Israel Institute of Technology, Haifa 32000 (Israel)

    2015-02-23

    Electron spin resonance (ESR) is a spectroscopic method that addresses electrons in paramagnetic materials directly through their spin properties. ESR has many applications, ranging from semiconductor characterization to structural biology and even quantum computing. Although it is very powerful and informative, ESR traditionally suffers from low sensitivity, requiring many millions of spins to get a measureable signal with commercial systems using the Faraday induction-detection principle. In view of this disadvantage, significant efforts were made recently to develop alternative detection schemes based, for example, on force, optical, or electrical detection of spins, all of which can reach single electron spin sensitivity. This sensitivity, however, comes at the price of limited applicability and usefulness with regard to real scientific and technological issues facing modern ESR which are currently dealt with conventional induction-detection ESR on a daily basis. Here, we present the most sensitive experimental induction-detection ESR setup and results ever recorded that can detect the signal from just a few tens of spins. They were achieved thanks to the development of an ultra-miniature micrometer-sized microwave resonator that was operated at ∼34 GHz at cryogenic temperatures in conjunction with a unique cryogenically cooled low noise amplifier. The test sample used was isotopically enriched phosphorus-doped silicon, which is of significant relevance to spin-based quantum computing. The sensitivity was experimentally verified with the aid of a unique high-resolution ESR imaging approach. These results represent a paradigm shift with respect to the capabilities and possible applications of induction-detection-based ESR spectroscopy and imaging.

  3. Electrochemical Detection of Circadian Redox Rhythm in Cyanobacterial Cells via Extracellular Electron Transfer.

    Science.gov (United States)

    Nishio, Koichi; Pornpitra, Tunanunkul; Izawa, Seiichiro; Nishiwaki-Ohkawa, Taeko; Kato, Souichiro; Hashimoto, Kazuhito; Nakanishi, Shuji

    2015-06-01

    Recent research on cellular circadian rhythms suggests that the coupling of transcription-translation feedback loops and intracellular redox oscillations is essential for robust circadian timekeeping. For clarification of the molecular mechanism underlying the circadian rhythm, methods that allow for the dynamic and simultaneous detection of transcription/translation and redox oscillations in living cells are needed. Herein, we report that the cyanobacterial circadian redox rhythm can be electrochemically detected based on extracellular electron transfer (EET), a process in which intracellular electrons are exchanged with an extracellular electrode. As the EET-based method is non-destructive, concurrent detection with transcription/translation rhythm using bioluminescent reporter strains becomes possible. An EET pathway that electrochemically connected the intracellular region of cyanobacterial cells with an extracellular electrode was constructed via a newly synthesized electron mediator with cell membrane permeability. In the presence of the mediator, the open circuit potential of the culture medium exhibited temperature-compensated rhythm with approximately 24 h periodicity. Importantly, such circadian rhythm of the open circuit potential was not observed in the absence of the electron mediator, indicating that the EET process conveys the dynamic information regarding the intracellular redox state to the extracellular electrode. These findings represent the first direct demonstration of the intracellular circadian redox rhythm of cyanobacterial cells. © The Author 2015. Published by Oxford University Press on behalf of Japanese Society of Plant Physiologists. All rights reserved. For permissions, please email: journals.permissions@oup.com.

  4. An empirical model to describe performance degradation for warranty abuse detection in portable electronics

    International Nuclear Information System (INIS)

    Oh, Hyunseok; Choi, Seunghyuk; Kim, Keunsu; Youn, Byeng D.; Pecht, Michael

    2015-01-01

    Portable electronics makers have introduced liquid damage indicators (LDIs) into their products to detect warranty abuse caused by water damage. However, under certain conditions, these indicators can exhibit inconsistencies in detecting liquid damage. This study is motivated by the fact that the reliability of LDIs in portable electronics is suspected. In this paper, first, the scheme of life tests is devised for LDIs in conjunction with a robust color classification rule. Second, a degradation model is proposed by considering the two physical mechanisms—(1) phase change from vapor to water and (2) water transport in the porous paper—for LDIs. Finally, the degradation model is validated with additional tests using actual smartphone sets subjected to the thermal cycling of −15 °C to 25 °C and the relative humidity of 95%. By employing the innovative life testing scheme and the novel performance degradation model, it is expected that the performance of LDIs for a particular application can be assessed quickly and accurately. - Highlights: • Devise an efficient scheme of life testing for a warranty abuse detector in portable electronics. • Develop a performance degradation model for the warranty abuse detector used in portable electronics. • Validate the performance degradation model with life tests of actual smartphone sets. • Help make a decision on warranty service in portable electronics manufacturers

  5. Measuring the Electronic Properties of DNA-Specific Schottky Diodes Towards Detecting and Identifying Basidiomycetes DNA

    Science.gov (United States)

    Periasamy, Vengadesh; Rizan, Nastaran; Al-Ta’ii, Hassan Maktuff Jaber; Tan, Yee Shin; Tajuddin, Hairul Annuar; Iwamoto, Mitsumasa

    2016-01-01

    The discovery of semiconducting behavior of deoxyribonucleic acid (DNA) has resulted in a large number of literatures in the study of DNA electronics. Sequence-specific electronic response provides a platform towards understanding charge transfer mechanism and therefore the electronic properties of DNA. It is possible to utilize these characteristic properties to identify/detect DNA. In this current work, we demonstrate a novel method of DNA-based identification of basidiomycetes using current-voltage (I-V) profiles obtained from DNA-specific Schottky barrier diodes. Electronic properties such as ideality factor, barrier height, shunt resistance, series resistance, turn-on voltage, knee-voltage, breakdown voltage and breakdown current were calculated and used to quantify the identification process as compared to morphological and molecular characterization techniques. The use of these techniques is necessary in order to study biodiversity, but sometimes it can be misleading and unreliable and is not sufficiently useful for the identification of fungi genera. Many of these methods have failed when it comes to identification of closely related species of certain genus like Pleurotus. Our electronics profiles, both in the negative and positive bias regions were however found to be highly characteristic according to the base-pair sequences. We believe that this simple, low-cost and practical method could be useful towards identifying and detecting DNA in biotechnology and pathology. PMID:27435636

  6. Characterization of a direct detection device imaging camera for transmission electron microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Milazzo, Anna-Clare, E-mail: amilazzo@ncmir.ucsd.edu [University of California at San Diego, 9500 Gilman Dr., La Jolla, CA 92093 (United States); Moldovan, Grigore [Department of Materials, University of Oxford, Parks Road, Oxford OX1 3PH (United Kingdom); Lanman, Jason [Department of Molecular Biology, The Scripps Research Institute, La Jolla, CA 92037 (United States); Jin, Liang; Bouwer, James C. [University of California at San Diego, 9500 Gilman Dr., La Jolla, CA 92093 (United States); Klienfelder, Stuart [University of California at Irvine, Irvine, CA 92697 (United States); Peltier, Steven T.; Ellisman, Mark H. [University of California at San Diego, 9500 Gilman Dr., La Jolla, CA 92093 (United States); Kirkland, Angus I. [Department of Materials, University of Oxford, Parks Road, Oxford OX1 3PH (United Kingdom); Xuong, Nguyen-Huu [University of California at San Diego, 9500 Gilman Dr., La Jolla, CA 92093 (United States)

    2010-06-15

    The complete characterization of a novel direct detection device (DDD) camera for transmission electron microscopy is reported, for the first time at primary electron energies of 120 and 200 keV. Unlike a standard charge coupled device (CCD) camera, this device does not require a scintillator. The DDD transfers signal up to 65 lines/mm providing the basis for a high-performance platform for a new generation of wide field-of-view high-resolution cameras. An image of a thin section of virus particles is presented to illustrate the substantially improved performance of this sensor over current indirectly coupled CCD cameras.

  7. Characterization of a direct detection device imaging camera for transmission electron microscopy

    International Nuclear Information System (INIS)

    Milazzo, Anna-Clare; Moldovan, Grigore; Lanman, Jason; Jin, Liang; Bouwer, James C.; Klienfelder, Stuart; Peltier, Steven T.; Ellisman, Mark H.; Kirkland, Angus I.; Xuong, Nguyen-Huu

    2010-01-01

    The complete characterization of a novel direct detection device (DDD) camera for transmission electron microscopy is reported, for the first time at primary electron energies of 120 and 200 keV. Unlike a standard charge coupled device (CCD) camera, this device does not require a scintillator. The DDD transfers signal up to 65 lines/mm providing the basis for a high-performance platform for a new generation of wide field-of-view high-resolution cameras. An image of a thin section of virus particles is presented to illustrate the substantially improved performance of this sensor over current indirectly coupled CCD cameras.

  8. GAGG:ce single crystalline films: New perspective scintillators for electron detection in SEM

    Czech Academy of Sciences Publication Activity Database

    Bok, Jan; Lalinský, Ondřej; Hanuš, M.; Onderišinová, Z.; Kelar, J.; Kučera, M.

    2016-01-01

    Roč. 163, APR (2016), s. 1-5 ISSN 0304-3991 R&D Projects: GA ČR(CZ) GA14-20012S; GA ČR(CZ) GA16-05631S; GA MŠk(CZ) LO1212; GA MŠk ED0017/01/01 Institutional support: RVO:68081731 Keywords : scintillator * GAGG:Ce * multicomponent garnet * epitaxial film * electron detection * SEM Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering Impact factor: 2.843, year: 2016

  9. Reliability considerations of electronics components for the deep underwater muon and neutrino detection system

    International Nuclear Information System (INIS)

    Leskovar, B.

    1980-02-01

    The reliability of some electronics components for the Deep Underwater Muon and Neutrino Detection (DUMAND) System is discussed. An introductory overview of engineering concepts and technique for reliability assessment is given. Component reliability is discussed in the contest of major factors causing failures, particularly with respect to physical and chemical causes, process technology and testing, and screening procedures. Failure rates are presented for discrete devices and for integrated circuits as well as for basic electronics components. Furthermore, the military reliability specifications and standards for semiconductor devices are reviewed

  10. Direct Detection Electron Energy-Loss Spectroscopy: A Method to Push the Limits of Resolution and Sensitivity.

    Science.gov (United States)

    Hart, James L; Lang, Andrew C; Leff, Asher C; Longo, Paolo; Trevor, Colin; Twesten, Ray D; Taheri, Mitra L

    2017-08-15

    In many cases, electron counting with direct detection sensors offers improved resolution, lower noise, and higher pixel density compared to conventional, indirect detection sensors for electron microscopy applications. Direct detection technology has previously been utilized, with great success, for imaging and diffraction, but potential advantages for spectroscopy remain unexplored. Here we compare the performance of a direct detection sensor operated in counting mode and an indirect detection sensor (scintillator/fiber-optic/CCD) for electron energy-loss spectroscopy. Clear improvements in measured detective quantum efficiency and combined energy resolution/energy field-of-view are offered by counting mode direct detection, showing promise for efficient spectrum imaging, low-dose mapping of beam-sensitive specimens, trace element analysis, and time-resolved spectroscopy. Despite the limited counting rate imposed by the readout electronics, we show that both core-loss and low-loss spectral acquisition are practical. These developments will benefit biologists, chemists, physicists, and materials scientists alike.

  11. Production and Detection of Spin-Entangled Electrons in Mesoscopic Conductors

    Science.gov (United States)

    Burkard, Guido

    2006-03-01

    Electron spins are an extremely versatile form of quantum bits. When localized in quantum dots, they can form a register for quantum computation. Moreover, being attached to a charge in a mesoscopic conductor allows the electron spin to play the role of a mobile carrier of quantum information similarly to photons in optical quantum communication. Since entanglement is a basic resource in quantum communication, the production and detection of spin-entangled Einstein-Podolsky-Rosen (EPR) pairs of electrons are of great interest. Besides the practical importance, it is of fundamental interest to test quantum non-locality for electrons. I review the theoretical schemes for the entanglement production in superconductor-normal junctions [1] and other systems. The electron spin entanglement can be detected and quantified from measurements of the fluctuations (shot noise) of the charge current after the electrons have passed through an electronic beam splitter [2,3]. This two-particle interference effect is related to the Hanbury-Brown and Twiss experiment and leads to a doubling of the shot noise SI=φ=0 for spin-entangled states, allowing their differentiation from unentangled pairs. I report on the role of spin-orbit coupling (Rashba and Dresselhaus) in a complete characterization of the spin entanglement [4]. Finally, I address the effects of a discrete level spectrum in the mesoscopic leads and of backscattering and decoherence.[1] P. Recher, E. V. Sukhorukov, D. Loss, Phys. Rev. B 63, 165314 (2001)[2] G. Burkard, D. Loss, E. V. Sukhorukov, Phys. Rev. B 61, R16303 (2000)[3] G. Burkard and D. Loss, Phys. Rev. Lett.91, 087903 (2003)[4] J. C. Egues, G. Burkard, D. Saraga, J. Schliemann, D. Loss, cond-mat/0509038, to appear in Phys.Rev.B (2005).

  12. An opto-electronic joint detection system based on DSP aiming at early cervical cancer screening

    Science.gov (United States)

    Wang, Weiya; Jia, Mengyu; Gao, Feng; Yang, Lihong; Qu, Pengpeng; Zou, Changping; Liu, Pengxi; Zhao, Huijuan

    2015-02-01

    The cervical cancer screening at a pre-cancer stage is beneficial to reduce the mortality of women. An opto-electronic joint detection system based on DSP aiming at early cervical cancer screening is introduced in this paper. In this system, three electrodes alternately discharge to the cervical tissue and three light emitting diodes in different wavelengths alternately irradiate the cervical tissue. Then the relative optical reflectance and electrical voltage attenuation curve are obtained by optical and electrical detection, respectively. The system is based on DSP to attain the portable and cheap instrument. By adopting the relative reflectance and the voltage attenuation constant, the classification algorithm based on Support Vector Machine (SVM) discriminates abnormal cervical tissue from normal. We use particle swarm optimization to optimize the two key parameters of SVM, i.e. nuclear factor and cost factor. The clinical data were collected on 313 patients to build a clinical database of tissue responses under optical and electrical stimulations with the histopathologic examination as the gold standard. The classification result shows that the opto-electronic joint detection has higher total coincidence rate than separate optical detection or separate electrical detection. The sensitivity, specificity, and total coincidence rate increase with the increasing of sample numbers in the training set. The average total coincidence rate of the system can reach 85.1% compared with the histopathologic examination.

  13. Direct Detection and Imaging of Low-Energy Electrons with Delta-Doped Charge-Coupled Devices

    Science.gov (United States)

    Nikzad, S.; Yu, Q.; Smith, A. L.; Jones, T. J.; Tombrello, T. A.; Elliott, S. T.

    1998-01-01

    We report the use fo delta-doped charge-coupled devices (CCDs) for direct detection of electrons in the 50-1500 eV energy range. These are the first measurements with a solid state device to detect electrons in this energy range.

  14. Automated detection of a prostate Ni-Ti stent in electronic portal images

    OpenAIRE

    Carl, Jesper; Nielsen, Henning; Nielsen, Jane; Lund, Bente; Larsen, Erik Hoejkjaer

    2006-01-01

      Udgivelsesdato: DEC  Planning target volumes (PTV) in fractionated radiotherapy still have to be outlined with wide margins to the clinical target volume due to uncertainties arising from daily shift of the prostate position. A recently proposed new method of visualization of the prostate is based on insertion of a thermo-expandable Ni-Ti stent. The current study proposes a new detection algorithm for automated detection of the Ni-Ti stent in electronic portal images. The algorithm is ba...

  15. J-PARC Press Release: Electron neutrino oscillation detected at T2K

    CERN Multimedia

    T2K Press Office

    2011-01-01

    Tsukuba, Japan, June 15, 2011. The T2K experiment, whose primary purpose is to study neutrino interactions at a large distance from their source, has detected 6 electron neutrino candidate events based on the data collected before March 11, 2011. For the first time, it was possible to observe an indication that muon neutrinos are able to transform into electron neutrinos over a distance of 295 km through the quantum mechanical phenomena of neutrino flavor oscillations.   The Super-Kamiokande detector, in Japan. © 2011, High Energy Accelerator Research Organization, KEK. The T2K experiment is searching for the neutrino oscillation phenomena, where particular types of neutrinos transform into other types of neutrinos. These observations help determine neutrino masses, as well elucidating the uncharted nature of neutrinos, such as the relationship among three neutrino generations (types). T2K aims at the world’s best sensitivity by detecting neutrinos with the Super-Kamiokande d...

  16. Conformational cycle of the vitamin B12 ABC importer in liposomes detected by double electron-electron resonance (DEER).

    Science.gov (United States)

    Joseph, Benesh; Korkhov, Vladimir M; Yulikov, Maxim; Jeschke, Gunnar; Bordignon, Enrica

    2014-02-07

    Double electron-electron resonance is used here to investigate intermediates of the transport cycle of the Escherichia coli vitamin B12 ATP-binding cassette importer BtuCD-F. Previously, we showed the ATP-induced opening of the cytoplasmic gate I in TM5 helices, later confirmed by the AMP-PNP-bound BtuCD-F crystal structure. Here, other key residues are analyzed in TM10 helices (positions 307 and 322) and in the cytoplasmic gate II, i.e. the loop between TM2 and TM3 (positions 82 and 85). Without BtuF, binding of ATP induces detectable changes at positions 307 and 85 in BtuCD in liposomes. Together with BtuF, ATP triggers the closure of the cytoplasmic gate II in liposomes (reported by both positions 82 and 85). This forms a sealed cavity in the translocation channel in agreement with the AMP-PNP·BtuCD-F x-ray structure. When vitamin B12 and AMP-PNP are simultaneously present, the extent of complex formation is reduced, but the short 82-82 interspin distance detected indicates that the substrate does not affect the closed conformation of this gate. The existence of the BtuCD-F complex under these conditions is verified with spectroscopically orthogonal nitroxide and Gd(III)-based labels. The cytoplasmic gate II remains closed also in the vanadate-trapped state, but it reopens in the ADP-bound state of the complex. Therefore, we suggest that the substrate likely trapped in ATP·BtuCD-F can be released after ATP hydrolysis but before the occluded ADP-bound conformation is reached.

  17. Automated Detection of Sepsis Using Electronic Medical Record Data: A Systematic Review.

    Science.gov (United States)

    Despins, Laurel A

    Severe sepsis and septic shock are global issues with high mortality rates. Early recognition and intervention are essential to optimize patient outcomes. Automated detection using electronic medical record (EMR) data can assist this process. This review describes automated sepsis detection using EMR data. PubMed retrieved publications between January 1, 2005 and January 31, 2015. Thirteen studies met study criteria: described an automated detection approach with the potential to detect sepsis or sepsis-related deterioration in real or near-real time; focused on emergency department and hospitalized neonatal, pediatric, or adult patients; and provided performance measures or results indicating the impact of automated sepsis detection. Detection algorithms incorporated systemic inflammatory response and organ dysfunction criteria. Systems in nine studies generated study or care team alerts. Care team alerts did not consistently lead to earlier interventions. Earlier interventions did not consistently translate to improved patient outcomes. Performance measures were inconsistent. Automated sepsis detection is potentially a means to enable early sepsis-related therapy but current performance variability highlights the need for further research.

  18. Autoradiographical Detection of Tritium in Cu-Ni Alloy by Scanning Electron Microscopy

    OpenAIRE

    高安, 紀; 中野, 美樹; 竹内, 豊三郎

    1981-01-01

    The autoradiograph of tritium dispersed in Cu-Ni alloy sheet by 6Li(n,α)3H reaction was obtained by a scanning electron microscope. Prior to the irradiation of neutrons 6Li was deposited on the sheet by evaporation. The liquid emulsion, Fuji-ER, was used in this study. The distribution of tritium was detected by the dispersion of silver grains remaining in the emulsion after the development was carried out.

  19. Study on application of the physical detection methods for electron beam-irradiated agricultural products

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dong Yong; Park, Yong Dae; Jin, Chang Hyun; Choi, Dae Seong; Jeong, Il Yun [Korea Atomic Energy Research Institute, Jeongeup (Korea, Republic of); Yook, Hong Sun [Chungnam National University, Daejeon (Korea, Republic of)

    2010-09-15

    Physical detection methods, photostimulated luminescence (PSL), thermoluminescence (TL) and electron spin resonance (ESR) were applied to detect electron beam-irradiated agricultural products, such as red pepper, black pepper, raisin, walnut, beef seasoning and pistachio. The absorbed irradiation doses for representative samples were controlled at 0, 1, 3, 5 and 10 kGy. PSL values for non-irradiated samples were <700 counts/60s (lower threshold, T{sub 1}) except beef seasoning, whereas those of irradiated samples were more than 5,000 photon counts, upper threshold (T{sub 2}) in black pepper, raisin, and beef seasoning and intermediates values of T{sub 1}-T{sub 2} in red pepper, walnut, and pistachio. Minerals separated from the samples for TL measurement showed that non-irradiated samples except pistachio (TL ratio, 0.12) were characterized by no glow curves situated at temperature range of 50 {approx} 400 .deg. C with TL ratio (0.01 {approx} 0.08), while irradiated samples except pistachio at only 1 kGy (TL ratio, 0.08) indicated glow curve at about 150 {approx} 250 .deg. C with TL ratio (0.28 {approx} 3.10). ESR measurements of irradiated samples any specific signals to irradiation. The samples of both red pepper ad pistachio were produced specific signals derived from cellulose radicals as well as single line signals for black pepper and walnut, and multiple signals derived from crystalline sugar radicals for raisin and beef seasoning. In conclusion, The ESR methods can apply for detection of pistachio exposed to electron beam but PSL and TL are not suitable methods. Furthermore, TL and ESR suggested that both techniques were more useful detection method than PSL to confirm whether red pepper, walnut and beef seasoning samples have been exposed to electron beam.

  20. Study on application of the physical detection methods for electron beam-irradiated agricultural products

    International Nuclear Information System (INIS)

    Kim, Dong Yong; Park, Yong Dae; Jin, Chang Hyun; Choi, Dae Seong; Jeong, Il Yun; Yook, Hong Sun

    2010-01-01

    Physical detection methods, photostimulated luminescence (PSL), thermoluminescence (TL) and electron spin resonance (ESR) were applied to detect electron beam-irradiated agricultural products, such as red pepper, black pepper, raisin, walnut, beef seasoning and pistachio. The absorbed irradiation doses for representative samples were controlled at 0, 1, 3, 5 and 10 kGy. PSL values for non-irradiated samples were 1 ) except beef seasoning, whereas those of irradiated samples were more than 5,000 photon counts, upper threshold (T 2 ) in black pepper, raisin, and beef seasoning and intermediates values of T 1 -T 2 in red pepper, walnut, and pistachio. Minerals separated from the samples for TL measurement showed that non-irradiated samples except pistachio (TL ratio, 0.12) were characterized by no glow curves situated at temperature range of 50 ∼ 400 .deg. C with TL ratio (0.01 ∼ 0.08), while irradiated samples except pistachio at only 1 kGy (TL ratio, 0.08) indicated glow curve at about 150 ∼ 250 .deg. C with TL ratio (0.28 ∼ 3.10). ESR measurements of irradiated samples any specific signals to irradiation. The samples of both red pepper ad pistachio were produced specific signals derived from cellulose radicals as well as single line signals for black pepper and walnut, and multiple signals derived from crystalline sugar radicals for raisin and beef seasoning. In conclusion, The ESR methods can apply for detection of pistachio exposed to electron beam but PSL and TL are not suitable methods. Furthermore, TL and ESR suggested that both techniques were more useful detection method than PSL to confirm whether red pepper, walnut and beef seasoning samples have been exposed to electron beam

  1. Detectability of pulmonary nodules with electronic collimation and conventional antiscatter grid

    International Nuclear Information System (INIS)

    Plenkovich, D.; Plavsic, B.; Robinson, A.E.; Lichtenstein, R.L.

    1989-01-01

    Electronic collimation is a method for rejection of scattered radiation and veiling glare in digital radiography. Digital images of a frozen, unembalmed, human chest phantom with simulated pulmonary nodules were obtained with use of the electronic collimation technique and a conventional 10:1 antiscatter grid. Observers were asked to locate multiple nodules and to record one of three levels of confidence. For each criterion, the total number of correct responses was divided by the total number of nodules to obtain the ordinate of a point. The total number of false-positive answers generated was divided by the number of images to obtain the abscissa of the point. The analysis was repeated for each scatter rejection method and for either the lungs or the mediastinum. The electronic collimation technique has improved the detectability of nodules projected over the mediastinum

  2. Energetic particles detected by the Electron Reflectometer instrument on the Mars Global Surveyor, 1999-2006

    DEFF Research Database (Denmark)

    Delory, Gregory T.; Luhmann, Janet G.; Brain, David

    2012-01-01

    events at Mars associated with solar flares and coronal mass ejections, which includes the identification of interplanetary shocks. MGS observations of energetic particles at varying geometries between the Earth and Mars that include shocks produced by halo, limb, and backsided events provide a unique......We report the observation of galactic cosmic rays and solar energetic particles by the Electron Reflectometer instrument aboard the Mars Global Surveyor (MGS) spacecraft from May of 1999 to the mission conclusion in November 2006. Originally designed to detect low-energy electrons, the Electron...... recorded high energy galactic cosmic rays with similar to 45% efficiency. Comparisons of this data to galactic cosmic ray proton fluxes obtained from the Advanced Composition Explorer yield agreement to within 10% and reveal the expected solar cycle modulation as well as shorter timescale variations. Solar...

  3. Electron beam sterilization of crude drug and its detection based on genetic analysis

    International Nuclear Information System (INIS)

    Satake, Motoyoshi; Sekita, Setsuko; Kamakura, Hiroyuki

    2000-01-01

    Chinese traditional crude drugs are medicines derived from natural materials so that most of them include various microorganisms such as soil microbials. Therefore, it is needed to develop a sterilization method for crude drugs not disturbing the efficacy of them. As one of such sterilization method, electron beam sterilization is paid attention now. In this study, the sterilizing effects of electron beam irradiation at various doses were investigated and the changes of low molecular substances were monitored. Phellodendron bark, rehmannia root, bupleurum root and Japanese angelica root samples were used as the subjects. Irradiation was made with γ-ray ( 60 Co) and electron beam at 5, 10, 20, 30 and 60 kGy and the number of organisms included in each drug and the contents of effective ingredients were determined after radiation exposure was determined. The number of microbials in these crude drugs were reduced ten times or more by electron beam irradiation, indicating that electron beam exposure has similar effects to those of γ-ray exposure at 10 kGy previously reported. Furthermore, the contents of effective ingredients of crude drugs, especially low molecular substances such as berberine, saponin, catalpol were not significantly changed by the electron beam exposure at the doses tested in this study and electron beam exposure as well as γ-ray exposure hardly affects those ingredients even at 60 kGy. Meanwhile, significant differences were observed in large molecular fractions of gel filtration chromatography between before and after the electron beam exposure at 60 kGy, suggesting that there were structural changes in some large molecules. In addition, to develop a detection method for these crude drugs, genomic DNA was extracted from them and digested with a restriction enzyme, MspI and EcoRI. Then, the ends of the respective DNAs were linked. After amplification by primary PCR, selective PCR was conducted with three MspI primers and EcoRI primer. The

  4. Electron beam sterilization of crude drug and its detection based on genetic analysis

    Energy Technology Data Exchange (ETDEWEB)

    Satake, Motoyoshi; Sekita, Setsuko; Kamakura, Hiroyuki [National Inst. of Health Sciences, Tokyo (Japan)

    2000-02-01

    Chinese traditional crude drugs are medicines derived from natural materials so that most of them include various microorganisms such as soil microbials. Therefore, it is needed to develop a sterilization method for crude drugs not disturbing the efficacy of them. As one of such sterilization method, electron beam sterilization is paid attention now. In this study, the sterilizing effects of electron beam irradiation at various doses were investigated and the changes of low molecular substances were monitored. Phellodendron bark, rehmannia root, bupleurum root and Japanese angelica root samples were used as the subjects. Irradiation was made with {gamma}-ray ({sup 60}Co) and electron beam at 5, 10, 20, 30 and 60 kGy and the number of organisms included in each drug and the contents of effective ingredients were determined after radiation exposure was determined. The number of microbials in these crude drugs were reduced ten times or more by electron beam irradiation, indicating that electron beam exposure has similar effects to those of {gamma}-ray exposure at 10 kGy previously reported. Furthermore, the contents of effective ingredients of crude drugs, especially low molecular substances such as berberine, saponin, catalpol were not significantly changed by the electron beam exposure at the doses tested in this study and electron beam exposure as well as {gamma}-ray exposure hardly affects those ingredients even at 60 kGy. Meanwhile, significant differences were observed in large molecular fractions of gel filtration chromatography between before and after the electron beam exposure at 60 kGy, suggesting that there were structural changes in some large molecules. In addition, to develop a detection method for these crude drugs, genomic DNA was extracted from them and digested with a restriction enzyme, MspI and EcoRI. Then, the ends of the respective DNAs were linked. After amplification by primary PCR, selective PCR was conducted with three MspI primers and Eco

  5. Chemical Selectivity and Sensitivity of a 16-Channel Electronic Nose for Trace Vapour Detection

    Directory of Open Access Journals (Sweden)

    Drago Strle

    2017-12-01

    Full Text Available Good chemical selectivity of sensors for detecting vapour traces of targeted molecules is vital to reliable detection systems for explosives and other harmful materials. We present the design, construction and measurements of the electronic response of a 16 channel electronic nose based on 16 differential microcapacitors, which were surface-functionalized by different silanes. The e-nose detects less than 1 molecule of TNT out of 10+12 N2 molecules in a carrier gas in 1 s. Differently silanized sensors give different responses to different molecules. Electronic responses are presented for TNT, RDX, DNT, H2S, HCN, FeS, NH3, propane, methanol, acetone, ethanol, methane, toluene and water. We consider the number density of these molecules and find that silane surfaces show extreme affinity for attracting molecules of TNT, DNT and RDX. The probability to bind these molecules and form a surface-adsorbate is typically 10+7 times larger than the probability to bind water molecules, for example. We present a matrix of responses of differently functionalized microcapacitors and we propose that chemical selectivity of multichannel e-nose could be enhanced by using artificial intelligence deep learning methods.

  6. The detection of electron-beam-induced current in junctionless semiconductor

    International Nuclear Information System (INIS)

    Tan, Chee Chin; Ong, Vincent K. S.

    2010-01-01

    The scanning electron microscope is a versatile tool and its electron beam techniques have been widely used in semiconductor material and device characterizations. One of these electron beam techniques is the electron-beam-induced current (EBIC) technique. One of the limitations of the conventional EBIC technique is that it requires charge collecting junctions which may not be readily available in junctionless samples such as bare substrates unless some special sample preparation procedure such as the fabrication of a diffused junction is done on the junctionless sample. In this paper, the technique of detecting EBIC current in junctionless samples with the use of a two-point probe is presented. It is found that the EBIC current is independent from its physical parameter when the sample thickness is greater than 4L; the width to the right of probe 2 and the width to the left of probe 1 are greater than 2L and 8L, respectively. The parameters affecting this technique of detecting the EBIC current such as the depth of the generation volume, probe spacing, and the applied bias are also discussed in this paper. A commercially available two-dimensional device simulator was used to verify this technique.

  7. Use of nonlocal helium microplasma for gas impurities detection by the collisional electron spectroscopy method

    Energy Technology Data Exchange (ETDEWEB)

    Kudryavtsev, Anatoly A., E-mail: akud@ak2138.spb.edu [St. Petersburg State University, 7-9 Universitetskaya nab., 199034 St. Petersburg (Russian Federation); Stefanova, Margarita S.; Pramatarov, Petko M. [Institute of Solid State Physics, Bulgarian Academy of Sciences, 72 Tzarigradsko Chaussee blvd., 1784 Sofia (Bulgaria)

    2015-10-15

    The collisional electron spectroscopy (CES) method, which lays the ground for a new field for analytical detection of gas impurities at high pressures, has been verified. The CES method enables the identification of gas impurities in the collisional mode of electron movement, where the advantages of nonlocal formation of the electron energy distribution function (EEDF) are fulfilled. Important features of dc negative glow microplasma and probe method for plasma diagnostics are applied. A new microplasma gas analyzer design is proposed. Admixtures of 0.2% Ar, 0.6% Kr, 0.1% N{sub 2}, and 0.05% CO{sub 2} are used as examples of atomic and molecular impurities to prove the possibility for detecting and identifying their presence in high pressure He plasma (50–250 Torr). The identification of the particles under analysis is made from the measurements of the high energy part of the EEDF, where maxima appear, resulting from the characteristic electrons released in Penning reactions of He metastable atoms with impurity particles. Considerable progress in the development of a novel miniature gas analyzer for chemical sensing in gas phase environments has been made.

  8. SEDHI: a new generation of detection electronics for earth observation satellites

    Science.gov (United States)

    Dantes, Didier; Neveu, Claude; Biffi, Jean-Marc; Devilliers, Christophe; Andre, Serge

    2017-11-01

    Future earth observation optical systems will be more and more demanding in terms of ground sampling distance, swath width, number of spectral bands, duty cycle. Existing architectures of focal planes and video processing electronics are hardly compatible with these new requirements: electronic functions are split in several units, and video processing is limited to frequencies around 5 MHz in order to fulfil the radiometric requirements expected for high performance image quality systems. This frequency limitation induces a high number of video chains operated in parallel to process the huge amount of pixels at focal plane output, and leads to unacceptable mass and power consumption budgets. Furthermore, splitting the detection electronics functions into several units (at least one for the focal plane and proximity electronics, and one for the video processing functions) does not optimise the production costs : specific development efforts must be performed on critical analogue electronics at each equipment level and operations of assembly, integration and tests are duplicated at equipment and subsystem levels. Alcatel Space Industries has proposed to CNES a new concept of highly integrated detection electronics (SEDHI), and is developing for CNES a breadboard which will allow to confirm its potentialities. This paper presents the trade-off study which have been performed before selection of this new concept and summarises the main advantages and drawbacks of each possible architecture. The electrical, mechanical and thermal aspects of the SEDHI concept are described, including the basic technologies : ASIC for phase shift of detector clocks, ASIC for video processing, hybrids, microchip module... The adaptability to a large amount of missions and optical instruments is also discussed.

  9. Introducing a Model for Suspicious Behaviors Detection in Electronic Banking by Using Decision Tree Algorithms

    Directory of Open Access Journals (Sweden)

    Rohulla Kosari Langari

    2014-02-01

    Full Text Available Change the world through information technology and Internet development, has created competitive knowledge in the field of electronic commerce, lead to increasing in competitive potential among organizations. In this condition The increasing rate of commercial deals developing guaranteed with speed and light quality is due to provide dynamic system of electronic banking until by using modern technology to facilitate electronic business process. Internet banking is enumerate as a potential opportunity the fundamental pillars and determinates of e-banking that in cyber space has been faced with various obstacles and threats. One of this challenge is complete uncertainty in security guarantee of financial transactions also exist of suspicious and unusual behavior with mail fraud for financial abuse. Now various systems because of intelligence mechanical methods and data mining technique has been designed for fraud detection in users’ behaviors and applied in various industrial such as insurance, medicine and banking. Main of article has been recognizing of unusual users behaviors in e-banking system. Therefore, detection behavior user and categories of emerged patterns to paper the conditions for predicting unauthorized penetration and detection of suspicious behavior. Since detection behavior user in internet system has been uncertainty and records of transactions can be useful to understand these movement and therefore among machine method, decision tree technique is considered common tool for classification and prediction, therefore in this research at first has determinate banking effective variable and weight of everything in internet behaviors production and in continuation combining of various behaviors manner draw out such as the model of inductive rules to provide ability recognizing of different behaviors. At least trend of four algorithm Chaid, ex_Chaid, C4.5, C5.0 has compared and evaluated for classification and detection of exist

  10. Detecting inpatient falls by using natural language processing of electronic medical records

    Directory of Open Access Journals (Sweden)

    Toyabe Shin-ichi

    2012-12-01

    Full Text Available Abstract Background Incident reporting is the most common method for detecting adverse events in a hospital. However, under-reporting or non-reporting and delay in submission of reports are problems that prevent early detection of serious adverse events. The aim of this study was to determine whether it is possible to promptly detect serious injuries after inpatient falls by using a natural language processing method and to determine which data source is the most suitable for this purpose. Methods We tried to detect adverse events from narrative text data of electronic medical records by using a natural language processing method. We made syntactic category decision rules to detect inpatient falls from text data in electronic medical records. We compared how often the true fall events were recorded in various sources of data including progress notes, discharge summaries, image order entries and incident reports. We applied the rules to these data sources and compared F-measures to detect falls between these data sources with reference to the results of a manual chart review. The lag time between event occurrence and data submission and the degree of injury were compared. Results We made 170 syntactic rules to detect inpatient falls by using a natural language processing method. Information on true fall events was most frequently recorded in progress notes (100%, incident reports (65.0% and image order entries (12.5%. However, F-measure to detect falls using the rules was poor when using progress notes (0.12 and discharge summaries (0.24 compared with that when using incident reports (1.00 and image order entries (0.91. Since the results suggested that incident reports and image order entries were possible data sources for prompt detection of serious falls, we focused on a comparison of falls found by incident reports and image order entries. Injury caused by falls found by image order entries was significantly more severe than falls detected by

  11. The electronic band structures of gadolinium chalcogenides: a first-principles prediction for neutron detecting.

    Science.gov (United States)

    Li, Kexue; Liu, Lei; Yu, Peter Y; Chen, Xiaobo; Shen, D Z

    2016-05-11

    By converting the energy of nuclear radiation to excited electrons and holes, semiconductor detectors have provided a highly efficient way for detecting them, such as photons or charged particles. However, for detecting the radiated neutrons, those conventional semiconductors hardly behave well, as few of them possess enough capability for capturing these neutral particles. While the element Gd has the highest nuclear cross section, here for searching proper neutron-detecting semiconductors, we investigate theoretically the Gd chalcogenides whose electronic band structures have never been characterized clearly. Among them, we identify that γ-phase Gd2Se3 should be the best candidate for neutron detecting since it possesses not only the right bandgap of 1.76 eV for devices working under room temperature but also the desired indirect gap nature for charge carriers surviving longer. We propose further that semiconductor neutron detectors with single-neutron sensitivity can be realized with such a Gd-chalcogenide on the condition that their crystals can be grown with good quality.

  12. High Magnetic Field in THz Plasma Wave Detection by High Electron Mobility Transistors

    Science.gov (United States)

    Sakowicz, M.; Łusakowski, J.; Karpierz, K.; Grynberg, M.; Valusis, G.

    The role of gated and ungated two dimensional (2D) electron plasma in THz detection by high electron mobility transistors (HEMTs) was investigated. THz response of GaAs/AlGaAs and GaN/AlGaN HEMTs was measured at 4.4K in quantizing magnetic fields with a simultaneous modulation of the gate voltage UGS. This allowed us to measure both the detection signal, S, and its derivative dS/dUGS. Shubnikov - de-Haas oscillations (SdHO) of both S and dS/dUGS were observed. A comparison of SdHO observed in detection and magnetoresistance measurements allows us to associate unambiguously SdHO in S and dS/dUGS with the ungated and gated parts of the transistor channel, respectively. This allows us to conclude that the entire channel takes part in the detection process. Additionally, in the case of GaAlAs/GaAs HEMTs, a structure related to the cyclotron resonance transition was observed.

  13. Detection of Off-Flavor in Catfish Using a Conducting Polymer Electronic-Nose Technology

    Science.gov (United States)

    Wilson, Alphus D.; Oberle, Charisse S.; Oberle, Daniel F.

    2013-01-01

    The Aromascan A32S conducting polymer electronic nose was evaluated for the capability of detecting the presence of off-flavor malodorous compounds in catfish meat fillets to assess meat quality for potential merchantability. Sensor array outputs indicated that the aroma profiles of good-flavor (on-flavor) and off-flavor fillets were strongly different as confirmed by a Principal Component Analysis (PCA) and a Quality Factor value (QF > 7.9) indicating a significant difference at (P 90%) and with relatively low rates (≤5%) of unknown or indecisive determinations in three trials. This A32S e-nose instrument also was capable of detecting the incidence of mild off-flavor in fillets at levels lower than the threshold of human olfactory detection. Potential applications of e-nose technologies for pre- and post-harvest management of production and meat-quality downgrade problems associated with catfish off-flavor are discussed. PMID:24287526

  14. Detection of an electron beam in a high density plasma via an electrostatic probe

    Science.gov (United States)

    Majeski, Stephen; Yoo, Jongsoo; Zweben, Stewart; Yamada, Masaaki; Ji, Hantao

    2017-10-01

    The perturbation in floating potential by an electron beam is detected by a 1D floating potential probe array to evaluate the use of an electron beam for magnetic field line mapping in the Magnetic Reconnection Experiment (MRX) plasma. The MRX plasma is relatively high density (1013 cm-3) and low temperature (5 eV). Beam electrons are emitted from a tungsten filament and are accelerated by a 200 V potential across the sheath. They stream along the magnetic field lines towards the probe array. The spatial electron beam density profile is assumed to be a Gaussian along the radial axis of MRX and the effective beam width is determined from the radial profile of the floating potential. The magnitude of the perturbation is in agreement with theoretical predictions and the location of the perturbation is also in agreement with field line mapping. In addition, no significant broadening of the electron beam is observed after propagation for tens of centimeters through the high density plasma. These results demonstrate that this method of field line mapping is, in principle, feasible in high density plasmas. This work is supported by the DOE Contract No. DE-AC0209CH11466.

  15. Virus Particle Detection by Convolutional Neural Network in Transmission Electron Microscopy Images.

    Science.gov (United States)

    Ito, Eisuke; Sato, Takaaki; Sano, Daisuke; Utagawa, Etsuko; Kato, Tsuyoshi

    2018-06-01

    A new computational method for the detection of virus particles in transmission electron microscopy (TEM) images is presented. Our approach is to use a convolutional neural network that transforms a TEM image to a probabilistic map that indicates where virus particles exist in the image. Our proposed approach automatically and simultaneously learns both discriminative features and classifier for virus particle detection by machine learning, in contrast to existing methods that are based on handcrafted features that yield many false positives and require several postprocessing steps. The detection performance of the proposed method was assessed against a dataset of TEM images containing feline calicivirus particles and compared with several existing detection methods, and the state-of-the-art performance of the developed method for detecting virus was demonstrated. Since our method is based on supervised learning that requires both the input images and their corresponding annotations, it is basically used for detection of already-known viruses. However, the method is highly flexible, and the convolutional networks can adapt themselves to any virus particles by learning automatically from an annotated dataset.

  16. Photoionisation detection of single 87Rb-atoms using channel electron multipliers

    International Nuclear Information System (INIS)

    Henkel, Florian Alexander

    2011-01-01

    Fast and efficient detection of single atoms is a universal requirement concerning modern experiments in atom physics, quantum optics, and precision spectroscopy. In particular for future quantum information and quantum communication technologies, the efficient readout of qubit states encoded in single atoms or ions is an elementary prerequisite. The rapid development in the field of quantum optics and atom optics in the recent years has enabled to prepare individual atoms as quantum memories or arrays of single atoms as qubit registers. With such systems, the implementation of quantum computation or quantum communication protocols seems feasible. This thesis describes a novel detection scheme which enables fast and efficient state analysis of single neutral atoms. The detection scheme is based on photoionisation and consists of two parts: the hyperfine-state selective photoionisation of single atoms and the registration of the generated photoion-electron pairs via two channel electron multipliers (CEMs). In this work, both parts were investigated in two separate experiments. For the first step, a photoionisation probability of p ion =0.991 within an ionisation time of t ion =386 ns is achieved for a single 87 Rb-atom in an optical dipole trap. For the second part, a compact detection system for the ionisation fragments was developed consisting of two opposing CEM detectors. Measurements show that single neutral atoms can be detected via their ionisation fragments with a detection efficiency of η atom =0.991 within a detection time of t det =415.5 ns. In a future combined setup, this will allow the state-selective readout of optically trapped, single neutral 87 Rb-atoms via photoionisation detection with an estimated detection efficiency η=0.982 and a detection time of t tot = 802 ns. Although initially developed for single 87 Rb-atoms, the concept of photoionisation detection is in principle generally applicable to any atomic or molecular species. As efficient

  17. Photoionisation detection of single {sup 87}Rb-atoms using channel electron multipliers

    Energy Technology Data Exchange (ETDEWEB)

    Henkel, Florian Alexander

    2011-09-02

    Fast and efficient detection of single atoms is a universal requirement concerning modern experiments in atom physics, quantum optics, and precision spectroscopy. In particular for future quantum information and quantum communication technologies, the efficient readout of qubit states encoded in single atoms or ions is an elementary prerequisite. The rapid development in the field of quantum optics and atom optics in the recent years has enabled to prepare individual atoms as quantum memories or arrays of single atoms as qubit registers. With such systems, the implementation of quantum computation or quantum communication protocols seems feasible. This thesis describes a novel detection scheme which enables fast and efficient state analysis of single neutral atoms. The detection scheme is based on photoionisation and consists of two parts: the hyperfine-state selective photoionisation of single atoms and the registration of the generated photoion-electron pairs via two channel electron multipliers (CEMs). In this work, both parts were investigated in two separate experiments. For the first step, a photoionisation probability of p{sub ion}=0.991 within an ionisation time of t{sub ion}=386 ns is achieved for a single {sup 87}Rb-atom in an optical dipole trap. For the second part, a compact detection system for the ionisation fragments was developed consisting of two opposing CEM detectors. Measurements show that single neutral atoms can be detected via their ionisation fragments with a detection efficiency of {eta}{sub atom}=0.991 within a detection time of t{sub det}=415.5 ns. In a future combined setup, this will allow the state-selective readout of optically trapped, single neutral {sup 87}Rb-atoms via photoionisation detection with an estimated detection efficiency {eta}=0.982 and a detection time of t{sub tot} = 802 ns. Although initially developed for single {sup 87}Rb-atoms, the concept of photoionisation detection is in principle generally applicable to any

  18. Data-driven drug safety signal detection methods in pharmacovigilance using electronic primary care records: A population based study

    Directory of Open Access Journals (Sweden)

    Shang-Ming Zhou

    2017-04-01

    Data-driven analytic methods are a valuable aid to signal detection of ADEs from large electronic health records for drug safety monitoring. This study finds the methods can detect known ADE and so could potentially be used to detect unknown ADE.

  19. Single-step reinforced microextraction of polycyclic aromatic hydrocarbons from soil samples using an inside needle capillary adsorption trap with electropolymerized aniline/multi-walled carbon nanotube sorbent.

    Science.gov (United States)

    Ghiasvand, Ali Reza; Yazdankhah, Fatemeh

    2017-03-03

    A polyaniline/multi-wall carbon nanotubes (PANI/MWCNT) composite was electrodeposited on the interior surface of a platinized stainless steel capillary needle and used to prepare an inside needle capillary adsorption trap (INCAT) device. The platinization expanded the interior adsorbing surface of the needle and made it more porous and cohesive for nanocomposite film. The nanocomposite was characterized using scanning electron microscopy (SEM) and Fourier transform infrared spectroscopy (FT-IR). The fabricated INCAT was fixed into a cooling capsule to fabricate a cooling-assisted INCAT (CA-INCAT) system. The CA-INCAT device was used to extract polycyclic aromatic hydrocarbons (PAHs) from solid samples followed by gas chromatography-flame ionization detection (GC-FID) determination. To obtain the best extraction efficiency, the important experimental variables were studied and optimized. Under the optimal conditions, the limits of detection (LODs) for the studied PAHs were in the range of 0.002-0.02ngg -1 . Linear dynamic ranges (LDRs) for the calibration curves were found to be 0.1-30,000ngg -1 . Relative standard deviations (RSDs%) for six replicated analysis of 1ngg -1 PAHs were obtained 7.7-11%. The CA-INCAT-GC-FID method was successfully applied for the extraction and determination of PAHs in contaminated soil samples. The results were in agreement with those obtained by a validated ultrasound-assisted solvent extraction (UA-SE) method. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Optical and electrical characterizations of a single step ion beam milling mesa devices of chloride passivated PbS colloidal quantum dots based film

    Energy Technology Data Exchange (ETDEWEB)

    Hechster, Elad, E-mail: elad.hechster@gmail.com; Sarusi, Gabby [Electro-Optics Engineering Unit and Ilse Katz Institute for Nanoscale Science and Technology, Ben-Gurion University of the Negev, Beer-Sheva, 84100 Israel (Israel); Shapiro, Arthur; Lifshitz, Efrat [Schulich Faculty of Chemistry, Solid State Institute, Russel Berrie Nanotechnology Institute, Technion – Israel Institute of technology, 32000 Haifa (Israel)

    2016-07-15

    Colloidal Quantum Dots (CQDs) are of increasing interest, thanks to their quantum size effect that gives rise to their usage in various applications, such as biological tagging, solar cells and as the sensitizing layer of night vision devices. Here, we analyze the optical absorbance of chloride passivated PbS CQDs as well as revealing a correlation between their photoluminescence and sizes distribution, using theoretical models and experimental results from the literature. Next, we calculate the CQDs resistivity as a film. Although resistivity can be calculated from sheet resistance measurement using four point probes, such measurement is usually carried-out on the layer’s surface that in most cases has dangling bonds and surface states, which might affect the charges flow and modify the resistivity. Therefore; our approach, which was applied in this work, is to extract the actual resistivity from measurements that are performed along the film’s thickness (z-direction). For this intent, we fabricated gold capped PbS mesas devices using a single step Ion Beam Milling (IBM) process where we milled the gold and the PbS film continually, and then measured the vertical resistance. Knowing the mesas’ dimensions, we calculate the resistivity. To the best of our knowledge, no previous work has extracted, vertically, the resistivity of chloride passivated PbS CQDs using the above method.

  1. Aesthetic rehabilitation of a patient with an anterior maxillectomy defect, using an innovative single-step, single unit, plastic-based hollow obturator

    Directory of Open Access Journals (Sweden)

    Vishwas Bhatia

    2015-06-01

    Full Text Available What could be better than improving the comfort and quality of life of a patient with a life-threatening disease? Maxillectomy, the partial or total removal of the maxilla in patients suffering from benign or malignant neoplasms, creates a challenging defect for the maxillofacial prosthodontist when attempting to provide an effective obturator. Although previous methods have been described for rehabilitation of such patients, our goal should be to devise one stage techniques that will allow the patient an improved quality of life as soon as possible. The present report describes the aesthetic rehabilitation of a maxillectomy patient by use of a hollow obturator. The obturator is fabricated through a processing technique which is a variation of other well-known techniques, consisting of the use of a single-step flasking procedure to fabricate a single-unit hollow obturator using the lost salt technique. As our aim is to aesthetically and functionally rehabilitate the patient as soon as possible, the present method of restoring the maxillectomy defect is cost-effective, time-saving and beneficial for the patient.

  2. Single-step generation of gene knockout-rescue system in pluripotent stem cells by promoter insertion with CRISPR/Cas9.

    Science.gov (United States)

    Matsunaga, Taichi; Yamashita, Jun K

    2014-02-07

    Specific gene knockout and rescue experiments are powerful tools in developmental and stem cell biology. Nevertheless, the experiments require multiple steps of molecular manipulation for gene knockout and subsequent rescue procedures. Here we report an efficient and single step strategy to generate gene knockout-rescue system in pluripotent stem cells by promoter insertion with CRISPR/Cas9 genome editing technology. We inserted a tetracycline-regulated inducible gene promoter (tet-OFF/TRE-CMV) upstream of the endogenous promoter region of vascular endothelial growth factor receptor 2 (VEGFR2/Flk1) gene, an essential gene for endothelial cell (EC) differentiation, in mouse embryonic stem cells (ESCs) with homologous recombination. Both homo- and hetero-inserted clones were efficiently obtained through a simple selection with a drug-resistant gene. The insertion of TRE-CMV promoter disrupted endogenous Flk1 expression, resulting in null mutation in homo-inserted clones. When the inserted TRE-CMV promoter was activated with doxycycline (Dox) depletion, Flk1 expression was sufficiently recovered from the downstream genomic Flk1 gene. Whereas EC differentiation was almost completely perturbed in homo-inserted clones, Flk1 rescue with TRE-CMV promoter activation restored EC appearance, indicating that phenotypic changes in EC differentiation can be successfully reproduced with this knockout-rescue system. Thus, this promoter insertion strategy with CRISPR/Cas9 would be a novel attractive method for knockout-rescue experiments. Copyright © 2014 Elsevier Inc. All rights reserved.

  3. Kinematic and kinetic analysis of the knee joint before and after a PCL retaining total knee replacement during gait and single step ascent.

    Science.gov (United States)

    Apostolopoulos, Alexandros; Lallos, Stergios; Mastrokalos, Dimitrios; Michos, Ioannis; Darras, Nikolaos; Tzomaki, Magda; Efstathopoulos, Nikolaos

    2011-01-01

    The objective of this study was to capture and analyze the kinetics and kinematics and determine the functional performance of the osteoarthritic knee after a posterior cruciate ligament (PCL) retaining total knee arthroplasty. Kinematic and kinetic gait analysis of level walking was performed in 20 subjects (12 female and 8 male) with knee ostoarthritis. These patients were free of any neurological diseases that could affect their normal gait. Mean age was 69.6 ± 6.6 years; mean height was 157.6 cm ± 7.6 cm; and mean weight was 77.2 ± 12.1 kg. Full body gait analyses were performed using the BIOKIN 3D motion analysis system before and 9 months after total knee arthroplasty procedures. Single-step ascending kinetic analyses and plantar pressure distribution analyses were also performed for all subjects. International Knee Society Scores (IKSSs) were also assessed pre- and postoperatively. Significant increases were noted postoperatively in average cadence (preoperative mean = 99.26, postoperative mean = 110.5; p knee adduction moment were also reported postoperatively. All patients showed a significant improvement of knee kinetics and kinematics after a PCL retaining total knee arthroplasty. Significant differences were found in the cadence, step length, stride length, and walk velocity postoperatively. IKSSs also significantly improved. Further research is warranted to determine the clinical relevance of these findings.

  4. Single-step transepithelial ASLA (SCHWIND) with mitomycin-C for the correction of high myopia: long term follow-up.

    Science.gov (United States)

    Aslanides, Ioannis M; Georgoudis, Panagiotis N; Selimis, Vasilis D; Mukherjee, Achyut N

    2015-01-01

    We wanted to compare the outcomes of single-step modified transepithelial photorefractive keratectomy (tPRK) termed a SCHWIND all surface laser ablation (ASLA) versus conventional alcohol-assisted photorefractive keratectomy (PRK) and laser-assisted in situ keratomileusis (LASIK) for the correction of higher myopia of 6.00 diopters (D) or more, in an area with high risk of haze due to high intensity of sunlight. We used a prospective interventional cohort with matched retrospective control groups. Patients with >6 D myopia and 0.05). Mean logMAR (logarithm of the minimum angle of resolution) uncorrected distance visual acuity at 12 months was 0.00 (SD: 0.05), 0.06 (SD: 0.1), and 0.05 (SD: 0.09) in the ASLA, PRK, and LASIK groups, with significantly better vision in the tPRK group versus LASIK (P=0.01) and PRK (P=0.01) groups. ASLA (SCHWIND) tPRK with mitomycin C for high myopia demonstrates comparable refractive outcomes to LASIK and PRK, with relatively favorable visual acuity outcomes. There was no increased incidence of haze in the ASLA group.

  5. Application of single-step genomic best linear unbiased prediction with a multiple-lactation random regression test-day model for Japanese Holsteins.

    Science.gov (United States)

    Baba, Toshimi; Gotoh, Yusaku; Yamaguchi, Satoshi; Nakagawa, Satoshi; Abe, Hayato; Masuda, Yutaka; Kawahara, Takayoshi

    2017-08-01

    This study aimed to evaluate a validation reliability of single-step genomic best linear unbiased prediction (ssGBLUP) with a multiple-lactation random regression test-day model and investigate an effect of adding genotyped cows on the reliability. Two data sets for test-day records from the first three lactations were used: full data from February 1975 to December 2015 (60 850 534 records from 2 853 810 cows) and reduced data cut off in 2011 (53 091 066 records from 2 502 307 cows). We used marker genotypes of 4480 bulls and 608 cows. Genomic enhanced breeding values (GEBV) of 305-day milk yield in all the lactations were estimated for at least 535 young bulls using two marker data sets: bull genotypes only and both bulls and cows genotypes. The realized reliability (R 2 ) from linear regression analysis was used as an indicator of validation reliability. Using only genotyped bulls, R 2 was ranged from 0.41 to 0.46 and it was always higher than parent averages. The very similar R 2 were observed when genotyped cows were added. An application of ssGBLUP to a multiple-lactation random regression model is feasible and adding a limited number of genotyped cows has no significant effect on reliability of GEBV for genotyped bulls. © 2016 Japanese Society of Animal Science.

  6. Single-step affinity and cost-effective purification of recombinant proteins using the Sepharose-binding lectin-tag from the mushroom Laetiporus sulphureus as fusion partner.

    Science.gov (United States)

    Li, Xiao-Jing; Liu, Jin-Ling; Gao, Dong-Sheng; Wan, Wen-Yan; Yang, Xia; Li, Yong-Tao; Chang, Hong-Tao; Chen, Lu; Wang, Chuan-Qing; Zhao, Jun

    2016-03-01

    Previous research showed that a lectin from the mushroom Laetiporus sulphureus, designed LSL, bound to Sepharose and could be eluted by lactose. In this study, by taking advantage of the strong affinity of LSL-tag for Sepharose, we developed a single-step purification method for LSL-tagged fusion proteins. We utilized unmodified Sepharose-4B as a specific adsorbent and 0.2 M lactose solution as an elution buffer. Fusion proteins of LSL-tag and porcine circovirus capsid protein, designated LSL-Cap was recovered with purity of 90 ± 4%, and yield of 87 ± 3% from crude extract of recombinant Escherichia coli. To enable the remove of LSL-tag, tobacco etch virus (TEV) protease recognition sequence was placed downstream of LSL-tag in the expression vector, and LSL-tagged TEV protease, designated LSL-TEV, was also expressed in E. coli., and was recovered with purity of 82 ± 5%, and yield of 85 ± 2% from crude extract of recombinant E. coli. After digestion of LSL-tagged recombinant proteins with LSL-TEV, the LSL tag and LSL-TEV can be easily removed by passing the digested products through the Sepharose column. It is of worthy noting that the Sepharose can be reused after washing with PBS. The LSL affinity purification method enables rapid and inexpensive purification of LSL-tagged fusion proteins and scale-up production of native proteins. Copyright © 2015 Elsevier Inc. All rights reserved.

  7. Polymer Nanocomposite Film with Metal Rich Surface Prepared by In Situ Single-Step Formation of Palladium Nanoparticles: An Interesting Way to Combine Specific Functional Properties

    Directory of Open Access Journals (Sweden)

    David Thompson

    2016-10-01

    Full Text Available This paper presents a continuous single-step route that permits preparation of a thermostable polymer/metal nanocomposite film and to combine different functional properties in a unique material. More precisely, palladium nanoparticles are in situ generated in a polyimide matrix thanks to a designed curing cycle which is applied to a polyamic acid/metal precursor solution cast on a glass plate. A metal-rich surface layer which is strongly bonded to the bulk film is formed in addition to homogeneously dispersed metal nanoparticles. This specific morphology leads to obtaining an optically reflective film. The metal nanoparticles act as gas diffusion barriers for helium, oxygen, and carbon dioxide; they induce a tortuosity effect which allows dividing the gas permeation coefficients by a factor near to 2 with respect to the neat polyimide matrix. Moreover, the ability of the in situ synthesized palladium nanoparticles to entrap hydrogen is evidenced. The nanocomposite film properties can be modulated as a function of the location of the film metal-rich surface with respect to the hydrogen feed. The synthesized nanocomposite could represent a major interest for a wide variety of applications, from specific coatings for aerospace or automotive industry, to catalysis applications or sensors.

  8. Optical and electrical characterizations of a single step ion beam milling mesa devices of chloride passivated PbS colloidal quantum dots based film

    International Nuclear Information System (INIS)

    Hechster, Elad; Sarusi, Gabby; Shapiro, Arthur; Lifshitz, Efrat

    2016-01-01

    Colloidal Quantum Dots (CQDs) are of increasing interest, thanks to their quantum size effect that gives rise to their usage in various applications, such as biological tagging, solar cells and as the sensitizing layer of night vision devices. Here, we analyze the optical absorbance of chloride passivated PbS CQDs as well as revealing a correlation between their photoluminescence and sizes distribution, using theoretical models and experimental results from the literature. Next, we calculate the CQDs resistivity as a film. Although resistivity can be calculated from sheet resistance measurement using four point probes, such measurement is usually carried-out on the layer’s surface that in most cases has dangling bonds and surface states, which might affect the charges flow and modify the resistivity. Therefore; our approach, which was applied in this work, is to extract the actual resistivity from measurements that are performed along the film’s thickness (z-direction). For this intent, we fabricated gold capped PbS mesas devices using a single step Ion Beam Milling (IBM) process where we milled the gold and the PbS film continually, and then measured the vertical resistance. Knowing the mesas’ dimensions, we calculate the resistivity. To the best of our knowledge, no previous work has extracted, vertically, the resistivity of chloride passivated PbS CQDs using the above method.

  9. Mesoporous-activated carbon prepared from chitosan flakes via single-step sodium hydroxide activation for the adsorption of methylene blue.

    Science.gov (United States)

    Marrakchi, F; Ahmed, M J; Khanday, W A; Asif, M; Hameed, B H

    2017-05-01

    In this work, mesoporous-activated carbon (CSAC) was prepared from chitosan flakes (CS) via single-step sodium hydroxide activation for the adsorption of methylene blue (MB). CSAC was prepared using different impregnation ratios of NaOH:CS (1:1, 2:1, 3:1, and 4:1) at 800°C for 90min. The adsorption performance of CSAC was evaluated for MB at different adsorption variables, such MB initial concentrations (25-400mg/L), solution pH (3-11), and temperature (30-50°C). The adsorption isotherm data of CSAC-MB were well fitted to Langmuir model with a maximum adsorption capacity 143.53mg/g at 50°C. Best representation of kinetic data was obtained by the pseudo-second order model. CSAC exhibited excellent adsorption uptake for MB and can potentially be used for other cationic dyes. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Single-step laser deposition of functionally graded coating by dual ‘wire powder’ or ‘powder powder’ feeding—A comparative study

    Science.gov (United States)

    Syed, Waheed Ul Haq; Pinkerton, Andrew J.; Liu, Zhu; Li, Lin

    2007-07-01

    The creation of iron-copper (Fe-Cu) alloys has practical application in improving the surface heat conduction and corrosion resistance of, for example, conformal cooling channels in steel moulds, but is difficult to achieve because the elements have got low inter-solubility and are prone to solidification cracking. Previous work by these authors has reported a method to produce a graded iron-nickel-copper coating in a single-step by direct diode laser deposition (DLD) of nickel wire and copper powder as a combined feedstock. This work investigates whether dual powder feeds can be used in that process to afford greater geometric flexibility and compares attributes of the 'nickel wire and copper powder' and 'nickel powder and copper powder' processes for deposition on a H13 tool steel substrate. In wire-powder deposition, a higher temperature developed in the melt pool causing a clad with a smooth gradient structure. The nickel powder in powder-powder deposition did not impart much heat into the melt pool so the melt pool solidified with sharp composition boundaries due to single metal melting in some parts. In wire-powder experiments, a graded structure was obtained by varying the flow rates of wire and powder. However, a graded structure was not realised in powder-powder experiments by varying either the feed or the directions. Reasons for the differences and flow patterns in the melt pools and their effect on final part properties of parts produced are discussed.

  11. Single Step Formation of C-TiO2 Nanotubes: Influence of Applied Voltage and Their Photocatalytic Activity under Solar Illumination

    Directory of Open Access Journals (Sweden)

    Chin Wei Lai

    2013-01-01

    Full Text Available Self-aligned and high-uniformity carbon (C- titania (TiO2 nanotube arrays were successfully formed via single step anodization of titanium (Ti foil at 30 V for 1 h in a bath composed of ethylene glycol (EG, ammonium fluoride (NH4F, and hydrogen peroxide (H2O2. It was well established that applied voltage played an important role in controlling field-assisted oxidation and field-assisted dissolution during electrochemical anodization process. Therefore, the influences of applied voltage on the formation of C-TiO2 nanotube arrays were discussed. It was found that a minimal applied voltage of 30 V was required to form the self-aligned and high-uniformity C-TiO2 nanotube arrays with diameter of ~75 nm and length of ~2 μm. The samples synthesized using different applied voltages were then subjected to heat treatment for the conversion of amorphous phase to crystalline phase. The photocatalytic activity evaluation of C-TiO2 samples was made under degradation of organic dye (methyl orange (MO solution. The results revealed that controlled nanoarchitecture C-TiO2 photocatalyst led to a significant enhancement in photocatalytic activity due to the creation of more specific active surface areas for incident photons absorption from the solar illumination.

  12. An Improved Single-Step Cloning Strategy Simplifies the Agrobacterium tumefaciens-Mediated Transformation (ATMT)-Based Gene-Disruption Method for Verticillium dahliae.

    Science.gov (United States)

    Wang, Sheng; Xing, Haiying; Hua, Chenlei; Guo, Hui-Shan; Zhang, Jie

    2016-06-01

    The soilborne fungal pathogen Verticillium dahliae infects a broad range of plant species to cause severe diseases. The availability of Verticillium genome sequences has provided opportunities for large-scale investigations of individual gene function in Verticillium strains using Agrobacterium tumefaciens-mediated transformation (ATMT)-based gene-disruption strategies. Traditional ATMT vectors require multiple cloning steps and elaborate characterization procedures to achieve successful gene replacement; thus, these vectors are not suitable for high-throughput ATMT-based gene deletion. Several advancements have been made that either involve simplification of the steps required for gene-deletion vector construction or increase the efficiency of the technique for rapid recombinant characterization. However, an ATMT binary vector that is both simple and efficient is still lacking. Here, we generated a USER-ATMT dual-selection (DS) binary vector, which combines both the advantages of the USER single-step cloning technique and the efficiency of the herpes simplex virus thymidine kinase negative-selection marker. Highly efficient deletion of three different genes in V. dahliae using the USER-ATMT-DS vector enabled verification that this newly-generated vector not only facilitates the cloning process but also simplifies the subsequent identification of fungal homologous recombinants. The results suggest that the USER-ATMT-DS vector is applicable for efficient gene deletion and suitable for large-scale gene deletion in V. dahliae.

  13. Automated detection of a prostate Ni-Ti stent in electronic portal images.

    Science.gov (United States)

    Carl, Jesper; Nielsen, Henning; Nielsen, Jane; Lund, Bente; Larsen, Erik Hoejkjaer

    2006-12-01

    Planning target volumes (PTV) in fractionated radiotherapy still have to be outlined with wide margins to the clinical target volume due to uncertainties arising from daily shift of the prostate position. A recently proposed new method of visualization of the prostate is based on insertion of a thermo-expandable Ni-Ti stent. The current study proposes a new detection algorithm for automated detection of the Ni-Ti stent in electronic portal images. The algorithm is based on the Ni-Ti stent having a cylindrical shape with a fixed diameter, which was used as the basis for an automated detection algorithm. The automated method uses enhancement of lines combined with a grayscale morphology operation that looks for enhanced pixels separated with a distance similar to the diameter of the stent. The images in this study are all from prostate cancer patients treated with radiotherapy in a previous study. Images of a stent inserted in a humanoid phantom demonstrated a localization accuracy of 0.4-0.7 mm which equals the pixel size in the image. The automated detection of the stent was compared to manual detection in 71 pairs of orthogonal images taken in nine patients. The algorithm was successful in 67 of 71 pairs of images. The method is fast, has a high success rate, good accuracy, and has a potential for unsupervised localization of the prostate before radiotherapy, which would enable automated repositioning before treatment and allow for the use of very tight PTV margins.

  14. Automated detection of a prostate Ni-Ti stent in electronic portal images

    International Nuclear Information System (INIS)

    Carl, Jesper; Nielsen, Henning; Nielsen, Jane; Lund, Bente; Larsen, Erik Hoejkjaer

    2006-01-01

    Planning target volumes (PTV) in fractionated radiotherapy still have to be outlined with wide margins to the clinical target volume due to uncertainties arising from daily shift of the prostate position. A recently proposed new method of visualization of the prostate is based on insertion of a thermo-expandable Ni-Ti stent. The current study proposes a new detection algorithm for automated detection of the Ni-Ti stent in electronic portal images. The algorithm is based on the Ni-Ti stent having a cylindrical shape with a fixed diameter, which was used as the basis for an automated detection algorithm. The automated method uses enhancement of lines combined with a grayscale morphology operation that looks for enhanced pixels separated with a distance similar to the diameter of the stent. The images in this study are all from prostate cancer patients treated with radiotherapy in a previous study. Images of a stent inserted in a humanoid phantom demonstrated a localization accuracy of 0.4-0.7 mm which equals the pixel size in the image. The automated detection of the stent was compared to manual detection in 71 pairs of orthogonal images taken in nine patients. The algorithm was successful in 67 of 71 pairs of images. The method is fast, has a high success rate, good accuracy, and has a potential for unsupervised localization of the prostate before radiotherapy, which would enable automated repositioning before treatment and allow for the use of very tight PTV margins

  15. Phosphorescent quantum dots/doxorubicin nanohybrids based on photoinduced electron transfer for detection of DNA.

    Science.gov (United States)

    Miao, Yanming; Zhang, Zhifeng; Gong, Yan; Yan, Guiqin

    2014-09-15

    MPA-capped Mn-doped ZnS QDs/DXR nanohybrids (MPA: 3-mercaptopropionic acid; QDs: quantum dots; DXR: cetyltrimethyl ammonium bromide) were constructed via photoinduced electron transfer (PIET) and then used as a room-temperature phosphorescence (RTP) probe for detection of DNA. DXR as a quencher will quench the RTP of Mn-doped ZnS QDs via PIET, thereby forming Mn-doped ZnS QDs/DXR nanohybrids and storing RTP. With the addition of DNA, it will be inserted into DXR and thus DXR will be competitively desorbed from the surface of Mn-doped ZnS QDs, thereby releasing the RTP of Mn-doped ZnS QDs. Based on this, a new method for DNA detection was built. The sensor for DNA has a detection limit of 0.039 mg L(-1) and a linear range from 0.1 to 14 mg L(-1). The present QDs-based RTP method does not need deoxidants or other inducers as required by conventional RTP detection methods, and avoids interference from autofluorescence and the scattering light of the matrix that are encountered in spectrofluorometry. Therefore, this method can be used to detect the DNA content in body fluid. Copyright © 2014 Elsevier B.V. All rights reserved.

  16. In situ hybridization at the electron microscope level: hybrid detection by autoradiography and colloidal gold.

    Science.gov (United States)

    Hutchison, N J; Langer-Safer, P R; Ward, D C; Hamkalo, B A

    1982-11-01

    In situ hybridization has become a standard method for localizing DNA or RNA sequences in cytological preparations. We developed two methods to extend this technique to the transmission electron microscope level using mouse satellite DNA hybridization to whole mount metaphase chromosomes as the test system. The first method devised is a direct extension of standard light microscope level using mouse satellite DNA hybridization to whole mount metaphase chromosomes as the test system. The first method devised is a direct extension of standard light microscope in situ hybridization. Radioactively labeled complementary RNA (cRNA) is hybridized to metaphase chromosomes deposited on electron microscope grids and fixed in 70 percent ethanol vapor; hybridixation site are detected by autoradiography. Specific and intense labeling of chromosomal centromeric regions is observed even after relatively short exposure times. Inerphase nuclei present in some of the metaphase chromosome preparations also show defined paatterms of satellite DNA labeling which suggests that satellite-containing regions are associate with each other during interphase. The sensitivity of this method is estimated to at least as good as that at the light microscope level while the resolution is improved at least threefold. The second method, which circumvents the use of autoradiogrphic detection, uses biotin-labeled polynucleotide probes. After hybridization of these probes, either DNA or RNA, to fixed chromosomes on grids, hybrids are detected via reaction is improved at least threefold. The second method, which circumvents the use of autoradiographic detection, uses biotin-labeled polynucleotide probes. After hybridization of these probes, either DNA or RNA, to fixed chromosomes on grids, hybrids are detected via reaction with an antibody against biotin and secondary antibody adsorbed to the surface of over centromeric heterochromatin and along the associated peripheral fibers. Labeling is on average

  17. An Opto-Electronic Sensor for Detecting Soil Microarthropods and Estimating Their Size in Field Conditions

    Directory of Open Access Journals (Sweden)

    Csongor I. Gedeon

    2017-08-01

    Full Text Available Methods to estimate density of soil-dwelling arthropods efficiently, accurately and continuously are critical for investigating soil biological activity and evaluating soil management practices. Soil-dwelling arthropods are currently monitored manually. This method is invasive, and time- and labor-consuming. Here we describe an infrared opto-electronic sensor for detection of soil microarthropods in the size range of 0.4–10 mm. The sensor is built in a novel microarthropod trap designed for field conditions. It allows automated, on-line, in situ detection and body length estimation of soil microarthropods. In the opto-electronic sensor the light source is an infrared LED. Two plano-convex optical lenses are placed along the virtual optical axis. One lens on the receiver side is placed between the observation space at 0.5–1 times its focal length from the sensor, and another emitter side lens is placed between the observation space and the light source in the same way. This paper describes the setup and operating mechanism of the sensor and the control unit, and through basic tests it demonstrates its potential in automated detection of soil microarthropods. The sensor may be used for monitoring activities, especially for remote observation activities in soil and insect ecology or pest control.

  18. Microfluidic CODES: a scalable multiplexed electronic sensor for orthogonal detection of particles in microfluidic channels.

    Science.gov (United States)

    Liu, Ruxiu; Wang, Ningquan; Kamili, Farhan; Sarioglu, A Fatih

    2016-04-21

    Numerous biophysical and biochemical assays rely on spatial manipulation of particles/cells as they are processed on lab-on-a-chip devices. Analysis of spatially distributed particles on these devices typically requires microscopy negating the cost and size advantages of microfluidic assays. In this paper, we introduce a scalable electronic sensor technology, called microfluidic CODES, that utilizes resistive pulse sensing to orthogonally detect particles in multiple microfluidic channels from a single electrical output. Combining the techniques from telecommunications and microfluidics, we route three coplanar electrodes on a glass substrate to create multiple Coulter counters producing distinct orthogonal digital codes when they detect particles. We specifically design a digital code set using the mathematical principles of Code Division Multiple Access (CDMA) telecommunication networks and can decode signals from different microfluidic channels with >90% accuracy through computation even if these signals overlap. As a proof of principle, we use this technology to detect human ovarian cancer cells in four different microfluidic channels fabricated using soft lithography. Microfluidic CODES offers a simple, all-electronic interface that is well suited to create integrated, low-cost lab-on-a-chip devices for cell- or particle-based assays in resource-limited settings.

  19. Development of an Electronic Kit for detecting asthma in Human Respiratory System

    Science.gov (United States)

    Shek Hong, Cheow; Ghani, Ahmad Shahrizan Abdul; Khairuddin, Ismail Mohd

    2018-03-01

    In this paper, a prototype of a carbon dioxide (CO2) measurement device is designed to detect and used to monitor asthma patients. Nowadays, capnogram device is widely used in monitoring asthma and asthma related medical services. However, capnogram is very costly and unaffordable for patient especially those who are in low income household. Thus, the proposed device is cost effective, affordable, and produced to detect and monitor the severity of asthma. Meanwhile, flow meter will cause patient to have chest pain as they needed maximum effort to blow in the device. To overcome these limitations, this prototype electronic kit is easy to use and suitable for all range patients. This prototype electronic kit consists of MH-Z14A carbon dioxide (CO2) sensor to detect the concentration of carbon dioxide from the user exhaled air. Arduino microcontroller is used to process the data while TFT Display shield is applied for data presentation. In addition, HC-06 Bluetooth module is used to communicate with PC for further analysis of the captured graph. This device was tested with 3 asthmatics and 3 normal users. The results showed that asthmatic user has a different graph pattern compared with normal user and these graphs are clearly differentiated on the device TFT screen. Asthmatic user produces “shark fin”-like pattern whereas normal user produces “square wave”-like pattern. This device has successfully produced distinguished-patterns difference between asthmatic and normal user; therefore, it is suitable for asthma monitoring.

  20. Potential application of electronic nose in processed animal proteins (PAP detection in feedstuffs

    Directory of Open Access Journals (Sweden)

    Dell'Orto V.

    2004-01-01

    Full Text Available Electronic nose and olfactometry techniques represent a modern analytical approach in food industry since they could potentially improve quality and safety of food processing. The aim of this study was to evaluate possible application of electronic nose in PA P detection and recognition in feed. For this purpose 6 reference feedstuffs (CRA-W / UE STRAT F E E D Project were used. The basis of the test samples was a compound feed for bovine fortified with processed animal proteins ( PAP consisting of meat and bone meal (MBM and/or fish meal at different concentrations. Each feed sample was tested in glass vials and the odour profile was determined by the ten MOS (metal oxide semi-conductor sensors of the electronic nose. Ten different descriptors, representing each ten sensors of electronic nose, were used to characterise the odour of each sample. In the present study, electronic nose was able to discriminate the blank sample from all other samples containing PA P ( M B M , fish meal or both. Samples containing either 0.5% of MBM or 5% of fish meal were identified, while samples containing a high fish meal content (5% associated with a low MBM content (0.5% were not discriminated from samples containing solely fish meal at that same high level (5%. This latter indicates that probably the high fish meal level, in samples containing both MBM and fish meal, tended to mask MBM odour. It was also evident that two odour descriptors were enough to explain 72.12% of total variability in odour pattern. In view of these results, it could be suggested that electronic nose and olfactometry techniques can provide an interesting approach for screening raw materials in feed industry, even though further studies using a wider set of samples are needed.

  1. An electronic channel switching-based aptasensor for ultrasensitive protein detection

    Energy Technology Data Exchange (ETDEWEB)

    Li Hongbo; Wang Cui [State Key Laboratory for Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University, Changsha 410082 (China); Wu Zaisheng, E-mail: wuzaisheng@163.com [State Key Laboratory for Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University, Changsha 410082 (China); Lu Limin; Qiu Liping; Zhou Hui; Shen Guoli [State Key Laboratory for Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University, Changsha 410082 (China); Yu Ruqin, E-mail: rqyu@hnu.edu.cn [State Key Laboratory for Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University, Changsha 410082 (China)

    2013-01-03

    Highlights: Black-Right-Pointing-Pointer Target IgE is successfully designed to serve as a barrier to separate enzyme from its substrate. Black-Right-Pointing-Pointer This sensing platform of electronic channel switching-based aptasensor can be simply manipulated. Black-Right-Pointing-Pointer The stable hairpin structure of anti-IgE aptamer is utilized to detect target IgE. Black-Right-Pointing-Pointer The sensor is ultrasensitive sensitivity, excellent selectivity and small volume of sample. Black-Right-Pointing-Pointer It is a powerful platform to be further expanded to detect more kinds of proteins and even cells. - Abstract: Due to the ubiquity and essential of the proteins in all living organisms, the identification and quantification of disease-specific proteins are particularly important. Because the conformational change of aptamer upon its target or probe/target/probe sandwich often is the primary prerequisite for the design of an electrochemical aptameric assay system, it is extremely difficult to construct the electrochemical aptasensor for protein assay because the corresponding aptamers cannot often meet the requirement. To circumvent the obstacles mentioned, an electronic channel switching-based (ECS) aptasensor for ultrasensitive protein detection is developed. The essential achievement made is that an innovative sensing concept is proposed: the hairpin structure of aptamer is designed to pull electroactive species toward electrode surface and makes the surface-immobilized IgE serve as a barrier that separates enzyme from its substrate. It seemingly ensures that the ECS aptasensor exhibits most excellent assay features, such as, a detection limit of 4.44 Multiplication-Sign 10{sup -6} {mu}g mL{sup -1} (22.7 fM, 220 zmol in 10-{mu}L sample) (demonstrating a 5 orders of magnitude improvement in detection sensitivity compared with classical electronic aptasensors) and dynamic response range from 4.44 Multiplication-Sign 10{sup -6} to 4.44 Multiplication

  2. Detection of prior irradiation in dried fruits by electron spin resonance (ESR)

    International Nuclear Information System (INIS)

    Esteves, M.P.; Andrade, M.E.; Empis, J.

    1998-01-01

    Complete text of publication follows. Dried almonds, raisins, dates and pistachio were irradiated using gamma radiation and electron beam with an average absorbed dose of 5 kGy. The radiation treatment was detected by ESR spectroscopy. Different parts of the dried fruits were analysed as follows: almonds: skin; raisins: dried pulp (at 30 deg C for one week); dates: dried pulp (at 30 deg C for one week) and stone; pistachio: nutshell. A Bruker ECS 106 EPR Spectrometer, at a microwave power of 0.4 mW, at room temperature was used. The analysis were carried out 2-3 months and 6 months after irradiation. A series of signals, tentatively described as 'cellulose-like', 'sugar-like' and 'complex' were observed, and some slight differences between spectra recorded from samples irradiated with gamma and electrons were evident

  3. Detection of prior irradiation in dried fruits by electron spin resonance (ESR)

    Energy Technology Data Exchange (ETDEWEB)

    Esteves, M P [Instituto Nacional de Investigacao Agraria (EAN), Oeiras (Portugal); Andrade, M E [Instituto Tecnologico e Nuclear (ITN), Sacavem (Portugal); Empis, J [Instituto Superior Tecnico (IST), Lisboa (Portugal)

    1999-12-31

    Complete text of publication follows. Dried almonds, raisins, dates and pistachio were irradiated using gamma radiation and electron beam with an average absorbed dose of 5 kGy. The radiation treatment was detected by ESR spectroscopy. Different parts of the dried fruits were analysed as follows: almonds: skin; raisins: dried pulp (at 30 deg C for one week); dates: dried pulp (at 30 deg C for one week) and stone; pistachio: nutshell. A Bruker ECS 106 EPR Spectrometer, at a microwave power of 0.4 mW, at room temperature was used. The analysis were carried out 2-3 months and 6 months after irradiation. A series of signals, tentatively described as `cellulose-like`, `sugar-like` and `complex` were observed, and some slight differences between spectra recorded from samples irradiated with gamma and electrons were evident.

  4. Lunar surface remanent magnetic fields detected by the electron reflection method

    Science.gov (United States)

    Lin, R. P.; Anderson, K. A.; Bush, R.; Mcguire, R. E.; Mccoy, J. E.

    1976-01-01

    We present maps of the lunar surface remanent magnetic fields detected by the electron reflection method. These maps provide substantial coverage of the latitude band from 30 N southward to 30 S with a resolution of about 40 km and a sensitivity of about 0.2 gamma at the lunar surface. Regions of remanent magnetization are observed ranging in size from the resolution limit of 1.25 deg to above approximately 60 deg. The largest contiguous region fills the Big Backside Basin where it is intersected by the spacecraft orbital tracks. Preliminary analyses of the maps show that the source regions of lunar limb compressions correspond to regions of strong surface magnetism, and that there does not appear to be sharply discontinuous magnetization at the edges of maria. We also analyze the electron reflection observations to obtain information on the direction and distribution of magnetization in the Van de Graaff anomaly region.

  5. Resistively detected NMR line shapes in a quasi-one-dimensional electron system

    Science.gov (United States)

    Fauzi, M. H.; Singha, A.; Sahdan, M. F.; Takahashi, M.; Sato, K.; Nagase, K.; Muralidharan, B.; Hirayama, Y.

    2017-06-01

    We observe variation in the resistively detected nuclear magnetic resonance (RDNMR) line shapes in quantum Hall breakdown. The breakdown occurs locally in a gate-defined quantum point contact (QPC) region. Of particular interest is the observation of a dispersive line shape occurring when the bulk two-dimensional electron gas (2DEG) set to νb=2 and the QPC filling factor to the vicinity of νQPC=1 , strikingly resemble the dispersive line shape observed on a 2D quantum Hall state. This previously unobserved line shape in a QPC points to a simultaneous occurrence of two hyperfine-mediated spin flip-flop processes within the QPC. Those events give rise to two different sets of nuclei polarized in the opposite direction and positioned at a separate region with different degrees of electronic spin polarization.

  6. Detection of defects in electron-irradiated synthetic silica quartz probed by positron annihilation

    International Nuclear Information System (INIS)

    Watauchi, Satoshi; Uedono, Akira; Ujihira, Yusuke; Yoda, Osamu.

    1994-01-01

    Defects in amorphous SiO 2 films, formed on MOS(metal/oxide/semiconductor) devices as gates, perturb its operation. The positron annihilation techniques, were applied to the study of the annealing behavior of the defects, introduced in the high purity synthetic quartz glass by the irradiation of 3-MeV electrons up to the 1x10 18 e - /cm 2 dosage. It was proved that the positron annihilation techniques were sufficiently sensitive to detect the defects in the electron-irradiated silica glasses. Three types of open-space defects were detected by the positron lifetime measurements. These can be attributed to monovacancy or divacancy type defects, vacancy clusters, and open-volume defects. A high formation probability (∼90%) of positroniums(Ps) was found in unirradiated specimens. These Ps were considered to be formed in open-volume defects. The formation probability of Ps was drastically decreased by the electron irradiation. But the size of open-volume defects was kept unchanged by the irradiation. These facts suggest that vacancy-type defects were introduced by the electron irradiation and that positrons were trapped in these defects. By the isochronal annealing in nitrogen atmosphere, the lifetime component (τ 2 ) and its relative intensity (I 2 ), attributed to positrons trapped in monovacancy or divacancy type defects and annihilated there, changed remarkably. τ 2 was constant in the temperature range up to 300degC, getting slightly shorter between 300degC and 700degC, and constant above 700degC. I 2 decreased gradually up to 300degC, constant between 300degC and 550degC, decreased above 550degC, and constant above 700degC. This revealed that the behavior of the defects, in which positrons were trapped, change by the elevation of the annealing temperature. (author)

  7. Semiconducting Polymer Photodetectors with Electron and Hole Blocking Layers: High Detectivity in the Near-Infrared

    Directory of Open Access Journals (Sweden)

    Xiong Gong

    2010-07-01

    Full Text Available Sensing from the ultraviolet-visible to the infrared is critical for a variety of industrial and scientific applications. Photodetectors with broad spectral response, from 300 nm to 1,100 nm, were fabricated using a narrow-band gap semiconducting polymer blended with a fullerene derivative. By using both an electron-blocking layer and a hole-blocking layer, the polymer photodetectors, operating at room temperature, exhibited calculated detectivities greater than 1013 cm Hz1/2/W over entire spectral range with linear dynamic range approximately 130 dB. The performance is comparable to or even better than Si photodetectors.

  8. Electron capture detection of sulphur gases in carbon dioxide at the parts-per-billion level

    International Nuclear Information System (INIS)

    Pick, M.E.

    1979-01-01

    A gas chromatograph with an electron capture detector has been used to determine sulphur gases in CO 2 at the parts-per-billion level, with particular application to the analysis of coolant from CO 2 cooled nuclear reactors. For COS, CS 2 , CH 3 SH, H 2 S and (CH 3 ) 2 S 2 the detector has a sensitivity comparable with the more commonly used flame photometric detector, but it is much less sensitive towards (CH 3 ) 2 S and thiophene. In addition, the paper describes a simple method for trapping sulphur gases which might enable detection of sub parts-per-billion levels of sulphur compounds. (Auth.)

  9. Detection by electron spin resonance of young cock irradiated with 60 Co

    International Nuclear Information System (INIS)

    Villavicencio, A.L.C.H.; Duarte, C.L.; Mastro, N.L. del.

    1992-01-01

    The Electron Spin Resonance was used to measuring the production of free radicals induced by ionizing radiation in young cock bones on doses of 3,5 and 7,0 K Gy. It was studied the design decay by 30 days after the irradiation in environment temperature. The results show that the measures by resonance in bones can be used for detecting if the flesh sample that has bone was irradiated or not. The measures show the possibility of use post-irradiation dosimetry in food producst. (C.G.C.)

  10. Electronic detection of surface plasmon polaritons by metal-oxide-silicon capacitor

    Directory of Open Access Journals (Sweden)

    Robert E. Peale

    2016-09-01

    Full Text Available An electronic detector of surface plasmon polaritons (SPPs is reported. SPPs optically excited on a metal surface using a prism coupler are detected by using a close-coupled metal-oxide-silicon (MOS capacitor. Incidence-angle dependence is explained by Fresnel transmittance calculations, which also are used to investigate the dependence of photo-response on structure dimensions. Electrodynamic simulations agree with theory and experiment and additionally provide spatial intensity distributions on and off the SPP excitation resonance. Experimental dependence of the photoresponse on substrate carrier type, carrier concentration, and back-contact biasing is qualitatively explained by simple theory of MOS capacitors.

  11. Predictive modeling of structured electronic health records for adverse drug event detection.

    Science.gov (United States)

    Zhao, Jing; Henriksson, Aron; Asker, Lars; Boström, Henrik

    2015-01-01

    The digitization of healthcare data, resulting from the increasingly widespread adoption of electronic health records, has greatly facilitated its analysis by computational methods and thereby enabled large-scale secondary use thereof. This can be exploited to support public health activities such as pharmacovigilance, wherein the safety of drugs is monitored to inform regulatory decisions about sustained use. To that end, electronic health records have emerged as a potentially valuable data source, providing access to longitudinal observations of patient treatment and drug use. A nascent line of research concerns predictive modeling of healthcare data for the automatic detection of adverse drug events, which presents its own set of challenges: it is not yet clear how to represent the heterogeneous data types in a manner conducive to learning high-performing machine learning models. Datasets from an electronic health record database are used for learning predictive models with the purpose of detecting adverse drug events. The use and representation of two data types, as well as their combination, are studied: clinical codes, describing prescribed drugs and assigned diagnoses, and measurements. Feature selection is conducted on the various types of data to reduce dimensionality and sparsity, while allowing for an in-depth feature analysis of the usefulness of each data type and representation. Within each data type, combining multiple representations yields better predictive performance compared to using any single representation. The use of clinical codes for adverse drug event detection significantly outperforms the use of measurements; however, there is no significant difference over datasets between using only clinical codes and their combination with measurements. For certain adverse drug events, the combination does, however, outperform using only clinical codes. Feature selection leads to increased predictive performance for both data types, in isolation and

  12. Development and Evaluation of an Automated, Home-Based, Electronic Questionnaire for Detecting COPD Exacerbations

    Directory of Open Access Journals (Sweden)

    Francisco de B. Velazquez-Peña

    2015-01-01

    Full Text Available Collaboration between patients and their medical and technical experts enabled the development of an automated questionnaire for the early detection of COPD exacerbations (AQCE. The questionnaire consisted of fourteen questions and was implemented on a computer system for use by patients at home in an un-supervised environment. Psychometric evaluation was conducted after a 6-month field trial. Fifty-two patients were involved in the development of the questionnaire. Reproducibility was studied using 19 patients (ICC = 0.94. Sixteen out of the 19 subjects started the 6 month-field trial with the computer application. Cronbach’s alpha of 0.81 was achieved. In the concurrent validity analysis, a correlation of 0.80 (p = 0.002 with the CCQ was reported. The results suggest that AQCE is a valid and reliable questionnaire, showing that an automated home-based electronic questionnaire may enable early detection of exacerbations of COPD.

  13. Tip-induced local strain on Mo S2/graphite detected by inelastic electron tunneling spectroscopy

    Science.gov (United States)

    Ko, Wonhee; Hus, Saban M.; Li, Xufan; Berlijn, Tom; Nguyen, Giang D.; Xiao, Kai; Li, An-Ping

    2018-03-01

    We report the detection of tip-induced local strain applied to the monolayer Mo S2 grown on a graphite substrate by scanning tunneling microscope. Monolayer Mo S2 behaves as both mechanical and tunneling barriers that prevent the tip from contacting the graphite while maintaining the tunneling current. Inelastic tunneling electron spectroscopy (IETS) is utilized to probe the phonon modes in graphite. As the tip pushes the sample, IETS reveals a continuous phonon softening in graphite, corroborated by a downward shift of the phonon energy as calculated by density-functional theory. Our results demonstrate a way to apply local mechanical strain and simultaneously detect the induced change in phonon modes by unitizing IETS with two-dimensional materials as a tunneling barrier.

  14. DETECTION OF SOME IRRADIATED NUTS BY ELECTRON SPIN RESONANCE (ESR) TECHNIQUE

    International Nuclear Information System (INIS)

    KHALLAF, M.F.; YASIN, N.M.N.; EL-NASHABY, F.M.; ALI, H.G.M.; EL-SHIEMY, S.M.

    2008-01-01

    The present investigation was carried out to establish the electron spin resonance (ESR) detection method for identifying irradiated nuts (almond and pistachio). Samples were irradiated with 2, 4 and 6 kGy and stored at room temperature (25± 2 0 C) for six months to study the possibility of detecting its previous irradiation treatments by ESR spectroscopy. Analysis was carried out just after irradiation treatment and during ambient storage period. The ESR signal intensities of irradiated samples were markedly increased correspondingly with irradiation dose as a result of free radicals generated by gamma irradiation so, all irradiated samples under investigation could be differentiated from non-irradiated ones immediately after irradiation treatment. The decay in radicals responsible of ESR signals showed the identification of irradiated almond (shell or edible part) and pistachio (edible part) was impossible after six months of ambient storage

  15. DETECTION OF SOME IRRADIATED NUTS BY ELECTRON SPIN RESONANCE (ESR) TECHNIQUE

    Energy Technology Data Exchange (ETDEWEB)

    KHALLAF, M F; YASIN, N M.N. [Food Science Dept., Faculty of Agriculture, Ain Shams University, Cairo (Egypt); EL-NASHABY, F M; ALI, H G.M.; EL-SHIEMY, S M [Nuclear Research Centre, Atomic Energy Authority, Cairo (Egypt)

    2008-07-01

    The present investigation was carried out to establish the electron spin resonance (ESR) detection method for identifying irradiated nuts (almond and pistachio). Samples were irradiated with 2, 4 and 6 kGy and stored at room temperature (25{+-} 2{sup 0}C) for six months to study the possibility of detecting its previous irradiation treatments by ESR spectroscopy. Analysis was carried out just after irradiation treatment and during ambient storage period. The ESR signal intensities of irradiated samples were markedly increased correspondingly with irradiation dose as a result of free radicals generated by gamma irradiation so, all irradiated samples under investigation could be differentiated from non-irradiated ones immediately after irradiation treatment. The decay in radicals responsible of ESR signals showed the identification of irradiated almond (shell or edible part) and pistachio (edible part) was impossible after six months of ambient storage.

  16. Evaluation of electron spin resonance technique for the detection of irradiated mango (Mangifera indica L.) fruits

    International Nuclear Information System (INIS)

    Bhushan, B.; Kadam, R.M.; Thomas, P.; Singh, B.B.

    1994-01-01

    The electron spin resonance (ESR) technique was examined as a method for the detection of irradiated mango fruits. A symmetric ESR signal at g = 1.988 was detected in the hard seed cover (endocarp), the dry epidermal layer (testa) surrounding the kernel, and the soft kernel portions of the seed from four mango cultivars. the amplitude of the signal in the epidermal layer and seed cover showed a dose-dependent increase over control values. Qualitatively, however, no new signal was observed following irradiation, except that line width increased by 50%. Methyl cellosolve washing greatly reduced the intensity of the endogenous and radiation (1.0 kGy)-induced ESR signals in the seed cover; results suggest phenolic substances as the source of free radicals. the similarity of naturally occurring ESR signals to that induced by irradiation seems to restrict the practical utility of this method in irradiated mangoes

  17. Intravascular detection of Giardia trophozoites in naturally infected mice. An electron microscopic study.

    Science.gov (United States)

    el-Shewy, K A; Eid, R A

    2003-06-01

    During routine transmission electron microscopic (TEM) examination of mice naturally infected with Giardia muris, an intense infection with Giardia trophozoites was demonstrated within intestinal and renal tissues. Examination of randomly taken sections from these heavily infected tissues revealed marked deep affection with mixed pathology. Duodenal sections were found loaded with Giardia trophozoites in intimate contact with necrotic gut cells. Some of these trophozoites were detected within central lacteal of damaged villi and nearby blood vessels. Interestingly, and for the first time to be demonstrated, morphologically identical G. muris trophozoite was detected in a renal blood vessel. An intense cellular immune reaction was obviously demonstrated with remarkable interaction between giant macrophages and the trophozoites particulates. Involvement of deep tissues by Giardia trophozoites and their presence within vascular channels could open up questions about the possible invasive and disseminative behavior of G. muris, particularly in heavily and naturally infected hosts.

  18. 14 GHz longitudinally detected electron spin resonance using microHall sensors

    Science.gov (United States)

    Bouterfas, M.; Mouaziz, S.; Popovic, R. S.

    2017-09-01

    In this work we developed a home-made LOngitudinally Detected Electron Spin Resonance (LODESR) spectrometer based on a microsize Hall sensor. A coplanar waveguide (CPW)-resonator is used to induce microwave-excitation on the sample at 14 GHz. We used InSb cross-shaped Hall devices with active areas of (10 μm × 10 μm) and (5 μm × 5 μm) . Signal intensities of the longitudinal magnetization component of DPPH and YIG samples of volumes about (10 μm) 3 and (5 μm) 3 , are measured under amplitude and frequency modulated microwave magnetic field generated by the CPW-resonator. At room temperature, 109spins /G √Hz sensitivity is achieved for 0.2mT linewidth, a result which is still better than most of inductive detected LODESR sensitivities.

  19. Use of an Electronic Tongue to Detect Geosmin in Distilled Water

    Science.gov (United States)

    Braga, Guilherme S.; Paterno, Leonardo G.; Fonseca, Fernando J.

    2011-11-01

    An electronic tongue (ET) system consisting of conducting polymer sensors was employed to detect geosmin (GSM) in distilled water. GSM is a tainting compound and known to cause undesirable tastes and odors in water and aquaculture farming. Diluted solutions of GSM were prepared in distilled water at different concentrations. The electrical response (capacitance) of the sensors was analyzed using principal analysis component (PCA). The data obtained were separated into different clusters indicating a good sensibility of the ET system to this compound in distilled water. The ET showed signal saturation for concentrations higher than 300 ng.L-1. So far, the detection limit of our system is 25 ng.L-1. Nevertheless, close grouping between repeated tests indicated that the ET system response is reproducible.

  20. Detection of irradiated fruits and vegetables by gas-chromatographic methods and electron spin-resonance

    Energy Technology Data Exchange (ETDEWEB)

    Farag, S.E.A. (National Centre for Radiation Research and Technology, Cairo (Egypt))

    1993-01-01

    Gas chromatographic methods detected some hydrocarbons esp. 17:1, 16:2, 15:0 and 14:1 in irradiated, Avocado, Papaya, Mangoes with 0.75, 1.5, 3.0 kGy and Apricot with 0.5 and 3.0 kGy. The detection of hydrocarbons was clearly at high doses but the low doses need more sensitive conditions using Liquid-Liquid-Gas chromatographic method as used here. Using Electron Spin-Resonance, produce a specific signal from irradiated onion (dried leaves) as well as apricot (hard coat of kernels) after some weeks of irradiation process but not clear with the other foodstuffs. (orig.)

  1. Clinical utility of simultaneous whole-body 18F-FDG PET/MRI as a single-step imaging modality in the staging of primary nasopharyngeal carcinoma.

    Science.gov (United States)

    Chan, Sheng-Chieh; Yeh, Chih-Hua; Yen, Tzu-Chen; Ng, Shu-Hang; Chang, Joseph Tung-Chieh; Lin, Chien-Yu; Yen-Ming, Tsang; Fan, Kang-Hsing; Huang, Bing-Shen; Hsu, Cheng-Lung; Chang, Kai-Ping; Wang, Hung-Ming; Liao, Chun-Ta

    2018-03-03

    Both head and neck magnetic resonance imaging (MRI) and 18F-fluorodeoxyglucose (18F-FDG) positron emission tomography (PET)/computed tomography (CT) play a crucial role in the staging of primary nasopharyngeal carcinoma (NPC). In this study, we sought to prospectively investigate the clinical utility of simultaneous whole-body 18F-FDG PET/MRI for primary staging of NPC patients. We examined 113 patients with histologically confirmed NPC who underwent pretreatment, simultaneous whole-body PET/MRI and PET/CT for primary tumor staging. The images obtained with the different imaging modalities were interpreted independently and compared with each other. PET/MRI increased the accuracy of head and neck MRI for assessment of primary tumor extent in four patients via addition of FDG uptake information to increase the conspicuity of morphologically subtle lesions. PET/MR images were more discernible than PET/CT images for mapping tumor extension, especially intracranial invasion. Regarding the N staging assessment, the sensitivity of PET/MRI (99.5%) was higher than that of head and neck MRI (94.2%) and PET/CT (90.9%). PET/MRI was particularly useful for distinguishing retropharyngeal nodal metastasis from adjacent nasopharyngeal tumors. For distant metastasis evaluation, PET/MRI exhibited a similar sensitivity (90% vs. 86.7% vs. 83.3%), but higher positive predictive value (93.1% vs. 78.8% vs. 83.3%) than whole-body MRI and PET/CT, respectively. For tumor staging of NPC, simultaneous whole-body PET/MRI was more accurate than head and neck MRI and PET/CT, and may serve as a single-step staging modality.

  2. Single-step selection of drug resistant Acinetobacter baylyi ADP1 mutants reveals a functional redundancy in the recruitment of multidrug efflux systems.

    Directory of Open Access Journals (Sweden)

    Anthony J Brzoska

    Full Text Available Members of the genus Acinetobacter have been the focus recent attention due to both their clinical significance and application to molecular biology. The soil commensal bacterium Acinetobacter baylyi ADP1 has been proposed as a model system for molecular and genetic studies, whereas in a clinical environment, Acinetobacter spp. are of increasing importance due to their propensity to cause serious and intractable systemic infections. Clinically, a major factor in the success of Acinetobacter spp. as opportunistic pathogens can be attributed to their ability to rapidly evolve resistance to common antimicrobial compounds. Whole genome sequencing of clinical and environmental Acinetobacter spp. isolates has revealed the presence of numerous multidrug transporters within the core and accessory genomes, suggesting that efflux is an important host defense response in this genus. In this work, we used the drug-susceptible organism A. baylyi ADP1 as a model for studies into the evolution of efflux mediated resistance in genus Acinetobacter, due to the high level of conservation of efflux determinants across four diverse Acinetobacter strains, including clinical isolates. A single exposure of therapeutic concentrations of chloramphenicol to populations of A. baylyi ADP1 cells produced five individual colonies displaying multidrug resistance. The major facilitator superfamily pump craA was upregulated in one mutant strain, whereas the resistance nodulation division pump adeJ was upregulated in the remaining four. Within the adeJ upregulated population, two different levels of adeJ mRNA transcription were observed, suggesting at least three separate mutations were selected after single-step exposure to chloramphenicol. In the craA upregulated strain, a T to G substitution 12 nt upstream of the craA translation initiation codon was observed. Subsequent mRNA stability analyses using this strain revealed that the half-life of mutant craA mRNA was significantly

  3. Single-step preparation of selected biological fluids for the high performance liquid chromatographic analysis of fat-soluble vitamins and antioxidants.

    Science.gov (United States)

    Lazzarino, Giacomo; Longo, Salvatore; Amorini, Angela Maria; Di Pietro, Valentina; D'Urso, Serafina; Lazzarino, Giuseppe; Belli, Antonio; Tavazzi, Barbara

    2017-12-08

    Fat-soluble vitamins and antioxidants are of relevance in health and disease. Current methods to extract these compounds from biological fluids mainly need use of multi-steps and multi organic solvents. They are time-consuming and difficult to apply to treat simultaneously large sample number. We here describe a single-step, one solvent extraction of fat-soluble vitamins and antioxidants from biological fluids, and the chromatographic separation of all-trans-retinoic acid, 25-hydroxycholecalciferol, all-trans-retinol, astaxanthin, lutein, zeaxanthin, trans-β-apo-8'-carotenal, γ-tocopherol, β-cryptoxanthin, α-tocopherol, phylloquinone, lycopene, α-carotene, β-carotene and coenzyme Q 10 . Extraction is obtained by adding one volume of biological fluid to two acetonitrile volumes, vortexing for 60s and incubating for 60min at 37°C under agitation. HPLC separation occurs in 30min using Hypersil C18, 100×4.6mm, 5μm particle size column, gradient from 70% methanol+30% H 2 O to 100% acetonitrile, flow rate of 1.0ml/min and 37°C column temperature. Compounds are revealed using highly sensitive UV-VIS diode array detector. The HPLC method suitability was assessed in terms of sensitivity, reproducibility and recovery. Using the present extraction and chromatographic conditions we obtained values of the fat-soluble vitamins and antioxidants in serum from 50 healthy controls similar to those found in literature. Additionally, the profile of these compounds was also measured in seminal plasma from 20 healthy fertile donors. Results indicate that this simple, rapid and low cost sample processing is suitable to extract fat-soluble vitamins and antioxidants from biological fluids and can be applied in clinical and nutritional studies. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Single-step synthesis of In{sub 2}O{sub 3} nanowires decorated with TeO{sub 2} nanobeads and their acetone-sensing properties

    Energy Technology Data Exchange (ETDEWEB)

    Park, Sunghoon; Kheel, Hyejoon; Sun, Gun-Joo; Lee, Chongmu [Inha University, Department of Materials Science and Engineering, Incheon (Korea, Republic of); Park, Sang Eon [Inha University, Department of Chemistry, Incheon (Korea, Republic of)

    2016-04-15

    In{sub 2}O{sub 3} nanowires decorated with TeO{sub 2} nanobeads were synthesized by a facile single-step thermal evaporation process, and their acetone-gas-sensing properties were examined. The diameters and lengths of the In{sub 2}O{sub 3} nanowires ranged from 10 to 20 nm and up to 100 μm, respectively, whereas the diameters of the TeO{sub 2} beads ranged from 50 to 200 nm. The TeO{sub 2}-decorated In{sub 2}O{sub 3} nanowire sensor showed stronger response to acetone gas than the pristine In{sub 2}O{sub 3} nanowire sensor. The pristine and TeO{sub 2}-decorated In{sub 2}O{sub 3} nanowires exhibited sensitivity of ∝10.13 and ∝24.87, respectively, to 200 ppm acetone at 300 C. The decorated nanowire sensor also showed much more rapid response and recovery than the latter. Both sensors showed the strongest response to acetone gas at 300 C, respectively. The mechanism and origin of the enhanced acetone-gas-sensing performance of the TeO{sub 2}-decorated In{sub 2}O{sub 3} nanowire sensor compared to the pristine In{sub 2}O{sub 3} nanowire sensor were discussed in detail. The enhanced sensing performance of the TeO{sub 2}-decorated In{sub 2}O{sub 3} nanowire is mainly due to the modulation of the potential barrier height at the TeO{sub 2}-In{sub 2}O{sub 3} interface, high catalytic activity of TeO{sub 2,} and creation of active adsorption sites by incorporation of TeO{sub 2}. (orig.)

  5. Effect of annealing temperature on a single step processed Cu{sub 2}ZnSnS{sub 4} thin film via solution method

    Energy Technology Data Exchange (ETDEWEB)

    Prabeesh, P.; Selvam, I. Packia; Potty, S.N.

    2016-05-01

    Cu{sub 2}ZnSnS{sub 4} (CZTS) is a promising material for thin film solar cell applications because of its excellent photovoltaic properties, high abundance and non-toxicity. Thin films of CZTS are generally fabricated by vacuum based techniques or by using toxic solvents and these routes reduce its attention as a low cost and environmental friendly material. In this study, we have prepared CZTS through a solution based single step approach using non-toxic chemicals by spin coating and studied the effect of annealing temperature in the range 350–550 °C in nitrogen atmosphere on structural, optical and electrical properties. XRD results revealed the formation of kesterite phase at all annealing temperatures, while the Raman studies indicated Cu{sub 2}SnS{sub 2} impurity phase in the film annealed at 550 °C. Band gap of the films annealed in nitrogen varies from 1.46 eV to 1.56 eV, depending on the annealing temperature. Optimum properties, such as, good crystallinity, dense structure, ideal band gap (1.49 eV) and good absorption coefficient (10{sup 4} cm{sup −1}), were obtained for the film annealed at 500 °C for 30 min in nitrogen. - Highlights: • Prepared CZTS film through one-step liquid based approach using non-toxic chemicals. • Studied the effect of N{sub 2} annealing on structural, optical and electrical properties. • The phase pure CZTS absorber film exhibited excellent photovoltaic properties • The film annealed at 500 °C for 30 min in nitrogen exhibited optimum properties.

  6. Use of genomic recursions and algorithm for proven and young animals for single-step genomic BLUP analyses--a simulation study.

    Science.gov (United States)

    Fragomeni, B O; Lourenco, D A L; Tsuruta, S; Masuda, Y; Aguilar, I; Misztal, I

    2015-10-01

    The purpose of this study was to examine accuracy of genomic selection via single-step genomic BLUP (ssGBLUP) when the direct inverse of the genomic relationship matrix (G) is replaced by an approximation of G(-1) based on recursions for young genotyped animals conditioned on a subset of proven animals, termed algorithm for proven and young animals (APY). With the efficient implementation, this algorithm has a cubic cost with proven animals and linear with young animals. Ten duplicate data sets mimicking a dairy cattle population were simulated. In a first scenario, genomic information for 20k genotyped bulls, divided in 7k proven and 13k young bulls, was generated for each replicate. In a second scenario, 5k genotyped cows with phenotypes were included in the analysis as young animals. Accuracies (average for the 10 replicates) in regular EBV were 0.72 and 0.34 for proven and young animals, respectively. When genomic information was included, they increased to 0.75 and 0.50. No differences between genomic EBV (GEBV) obtained with the regular G(-1) and the approximated G(-1) via the recursive method were observed. In the second scenario, accuracies in GEBV (0.76, 0.51 and 0.59 for proven bulls, young males and young females, respectively) were also higher than those in EBV (0.72, 0.35 and 0.49). Again, no differences between GEBV with regular G(-1) and with recursions were observed. With the recursive algorithm, the number of iterations to achieve convergence was reduced from 227 to 206 in the first scenario and from 232 to 209 in the second scenario. Cows can be treated as young animals in APY without reducing the accuracy. The proposed algorithm can be implemented to reduce computing costs and to overcome current limitations on the number of genotyped animals in the ssGBLUP method. © 2015 Blackwell Verlag GmbH.

  7. One-Port Electronic Detection Strategies for Improving Sensitivity in Piezoelectric Resonant Sensor Measurements

    Directory of Open Access Journals (Sweden)

    Zhongxu Hu

    2016-10-01

    Full Text Available This paper describes a one-port mechanical resonance detection scheme utilized on a piezoelectric thin film driven silicon circular diaphragm resonator and discusses the limitations to such an approach in degenerate mode mass detection sensors. The sensor utilizes degenerated vibration modes of a radial symmetrical microstructure thereby providing both a sense and reference mode allowing for minimization of environmental effects on performance. The circular diaphragm resonator was fabricated with thickness of 4.5 µm and diameter of 140 µm. A PZT thin film of 0.75 µm was patterned on the top surface for the purposes of excitation and vibration sensing. The device showed a resonant frequency of 5.8 MHz for the (1, 1 mode. An electronic interface circuit was designed to cancel out the large static and parasitic capacitance allowing for electrical detection of the mechanical vibration thereby enabling the frequency split between the sense and reference mode to be measured accurately. The extracted motional current, proportional to the vibration velocity, was fed back to the drive to effectively increase the Q factor, and therefore device sensitivity, by more than a factor of 8. A software phase-locked loop was implemented to automatically track the resonant frequencies to allow for faster and accurate resonance detection. Results showed that by utilizing the absolute mode frequencies as an indication of sensor temperature, the variation in sensor temperature due to the heating from the drive electronics was accounted for and led to an ultimate measurement sensitivity of 2.3 Hz.

  8. One-Port Electronic Detection Strategies for Improving Sensitivity in Piezoelectric Resonant Sensor Measurements

    Science.gov (United States)

    Hu, Zhongxu; Hedley, John; Keegan, Neil; Spoors, Julia; Gallacher, Barry; McNeil, Calum

    2016-01-01

    This paper describes a one-port mechanical resonance detection scheme utilized on a piezoelectric thin film driven silicon circular diaphragm resonator and discusses the limitations to such an approach in degenerate mode mass detection sensors. The sensor utilizes degenerated vibration modes of a radial symmetrical microstructure thereby providing both a sense and reference mode allowing for minimization of environmental effects on performance. The circular diaphragm resonator was fabricated with thickness of 4.5 µm and diameter of 140 µm. A PZT thin film of 0.75 µm was patterned on the top surface for the purposes of excitation and vibration sensing. The device showed a resonant frequency of 5.8 MHz for the (1, 1) mode. An electronic interface circuit was designed to cancel out the large static and parasitic capacitance allowing for electrical detection of the mechanical vibration thereby enabling the frequency split between the sense and reference mode to be measured accurately. The extracted motional current, proportional to the vibration velocity, was fed back to the drive to effectively increase the Q factor, and therefore device sensitivity, by more than a factor of 8. A software phase-locked loop was implemented to automatically track the resonant frequencies to allow for faster and accurate resonance detection. Results showed that by utilizing the absolute mode frequencies as an indication of sensor temperature, the variation in sensor temperature due to the heating from the drive electronics was accounted for and led to an ultimate measurement sensitivity of 2.3 Hz. PMID:27792154

  9. Detection and Classification of Human Body Odor Using an Electronic Nose

    Directory of Open Access Journals (Sweden)

    Teerakiat Kerdcharoen

    2009-09-01

    Full Text Available An electronic nose (E-nose has been designed and equipped with software that can detect and classify human armpit body odor. An array of metal oxide sensors was used for detecting volatile organic compounds. The measurement circuit employs a voltage divider resistor to measure the sensitivity of each sensor. This E-nose was controlled by in-house developed software through a portable USB data acquisition card with a principle component analysis (PCA algorithm implemented for pattern recognition and classification. Because gas sensor sensitivity in the detection of armpit odor samples is affected by humidity, we propose a new method and algorithms combining hardware/software for the correction of the humidity noise. After the humidity correction, the E-nose showed the capability of detecting human body odor and distinguishing the body odors from two persons in a relative manner. The E-nose is still able to recognize people, even after application of deodorant. In conclusion, this is the first report of the application of an E-nose for armpit odor recognition.

  10. Detection and classification of human body odor using an electronic nose.

    Science.gov (United States)

    Wongchoosuk, Chatchawal; Lutz, Mario; Kerdcharoen, Teerakiat

    2009-01-01

    An electronic nose (E-nose) has been designed and equipped with software that can detect and classify human armpit body odor. An array of metal oxide sensors was used for detecting volatile organic compounds. The measurement circuit employs a voltage divider resistor to measure the sensitivity of each sensor. This E-nose was controlled by in-house developed software through a portable USB data acquisition card with a principle component analysis (PCA) algorithm implemented for pattern recognition and classification. Because gas sensor sensitivity in the detection of armpit odor samples is affected by humidity, we propose a new method and algorithms combining hardware/software for the correction of the humidity noise. After the humidity correction, the E-nose showed the capability of detecting human body odor and distinguishing the body odors from two persons in a relative manner. The E-nose is still able to recognize people, even after application of deodorant. In conclusion, this is the first report of the application of an E-nose for armpit odor recognition.

  11. DNA-mediated strand displacement facilitates sensitive electronic detection of antibodies in human serums.

    Science.gov (United States)

    Dou, Baoting; Yang, Jianmei; Shi, Kai; Yuan, Ruo; Xiang, Yun

    2016-09-15

    We describe here the development of a sensitive and convenient electronic sensor for the detection of antibodies in human serums. The sensor is constructed by self-assembly formation of a mixed monolayer containing the small molecule epitope conjugated double stranded DNA probes on gold electrode. The target antibody binds the epitope on the dsDNA probe and lowers the melting temperature of the duplex, which facilitates the displacement of the antibody-linked strand of the duplex probe by an invading methylene blue-tagged single stranded DNA (MB-ssDNA) through the strand displacement reaction and leads to the capture of many MB-ssDNA on the sensor surface. Subsequent electrochemical oxidation of the methylene blue labels results in amplified current response for sensitive monitoring of the antibodies. The antibody assay conditions are optimized and the sensor exhibits a linear range between 1.0 and 25.0nM with a detection limit of 0.67nM for the target antibody. The sensor is also selective and can be employed to detect the target antibodies in human serum samples. With the advantages of using small molecule epitope as the antibody recognition element over traditional antigen, the versatile manipulability of the DNA probes and the unique properties of the electrochemical transduction technique, the developed sensor thus hold great potential for simple and sensitive detection of different antibodies and other proteins in real samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  12. Ionospheric earthquake effects detection based on Total Electron Content (TEC) GPS Correlation

    Science.gov (United States)

    Sunardi, Bambang; Muslim, Buldan; Eka Sakya, Andi; Rohadi, Supriyanto; Sulastri; Murjaya, Jaya

    2018-03-01

    Advances in science and technology showed that ground-based GPS receiver was able to detect ionospheric Total Electron Content (TEC) disturbances caused by various natural phenomena such as earthquakes. One study of Tohoku (Japan) earthquake, March 11, 2011, magnitude M 9.0 showed TEC fluctuations observed from GPS observation network spread around the disaster area. This paper discussed the ionospheric earthquake effects detection using TEC GPS data. The case studies taken were Kebumen earthquake, January 25, 2014, magnitude M 6.2, Sumba earthquake, February 12, 2016, M 6.2 and Halmahera earthquake, February 17, 2016, M 6.1. TEC-GIM (Global Ionosphere Map) correlation methods for 31 days were used to monitor TEC anomaly in ionosphere. To ensure the geomagnetic disturbances due to solar activity, we also compare with Dst index in the same time window. The results showed anomalous ratio of correlation coefficient deviation to its standard deviation upon occurrences of Kebumen and Sumba earthquake, but not detected a similar anomaly for the Halmahera earthquake. It was needed a continous monitoring of TEC GPS data to detect the earthquake effects in ionosphere. This study giving hope in strengthening the earthquake effect early warning system using TEC GPS data. The method development of continuous TEC GPS observation derived from GPS observation network that already exists in Indonesia is needed to support earthquake effects early warning systems.

  13. Probability of defect detection of Posiva's electron beam weld

    International Nuclear Information System (INIS)

    Kanzler, D.; Mueller, C.; Pitkaenen, J.

    2013-12-01

    The report 'Probability of Defect Detection of Posiva's electron beam weld' describes POD curves of four NDT methods radiographic testing, ultrasonic testing, eddy current testing and visual testing. POD-curves are based on the artificial defects in reference blocks. The results are devoted to the demonstration of suitability of the methods for EB weld testing. Report describes methodology and procedure applied by BAM. Report creates a link from the assessment of the reliability and inspection performance to the risk assessment process of the canister final disposal project. Report ensures the confirmation of the basic quality of the NDT methods and their capability to describe the quality of the EB-weld. The probability of detection curves are determined based on the MIL-1823 standard and it's reliability guidelines. The MIL-1823 standard was developed for the determination of integrity of gas turbine engines for the US military. In the POD-process there are determined as a key parameter for the defect detectability the a90/95 magnitudes, i.e. the size measure a of the defect, for which the lower 95 % confidence band crosses the 90 % POD level. By this way can be confirmed that defects with a size of a90/95 will be detected with 90 % probability. In case the experiment will be repeated 5 % might fall outside this confidence limit. (orig.)

  14. Ultra-low current biosensor output detection using portable electronic reader

    Science.gov (United States)

    Yahaya, N. A. N.; Rajapaksha, R. D. A. A.; Uda, M. N. Afnan; Hashim, U.

    2017-09-01

    Generally, the electrical biosensor usually shows extremely low current signal output around pico ampere to microampere range. In this research, electronic reader with amplifier has been demonstrated to detect ultra low current via the biosensor. The operational amplifier Burr-Brown OPA 128 and Arduino Uno board were used to construct the portable electronic reader. There are two cascaded inverting amplifier were used to detect ultra low current through the biosensor from pico amperes (pA) to nano amperes ranges (nA). A small known input current was form by applying variable voltage between 0.1V to 5.0V across a 5GΩ high resistor to check the amplifier circuit. The amplifier operation was measured with the high impedance current source and has been compared with the theoretical measurement. The Arduino Uno was used to convert the analog signal to digital signal and process the data to display on reader screen. In this project, Proteus software was used to design and test the circuit. Then it was implemented together with Arduino Uno board. Arduino board was programmed using C programming language to make whole circuit communicate each order. The current was measured then it shows a small difference values compared to theoretical values, which is approximately 14pA.

  15. Detecting aroma changes of local flavored green tea (Camellia sinensis) using electronic nose

    Science.gov (United States)

    Ralisnawati, D.; Sukartiko, A. C.; Suryandono, A.; Triyana, K.

    2018-03-01

    Indonesia is currently the sixth largest tea producer in the world. However, consumption of the product in the country was considered low. Besides tea, the country also has various local flavor ingredients that are potential to be developed. The addition of local flavored ingredients such as ginger, lemon grass, and lime leaves on green tea products is gaining acceptance from consumers and producers. The aroma of local flavored green tea was suspected to changes during storage, while its sensory testing has some limitations. Therefore, the study aimed to detect aroma changes of local flavors added in green tea using electronic nose (e-nose), an instrument developed to mimic the function of the human nose. The test was performed on a four-gram sample. The data was collected with 120 seconds of sensing time and 60 seconds of blowing time. Principal Component Analysis (PCA) was used to find out the aroma changes of local flavored green tea during storage. We observed that electronic nose could detect aroma changes of ginger flavored green tea from day 0 to day 6 with variance percentage 99.6%. Variance proportion of aroma changes of lemon grass flavored green tea from day 0 to day 6 was 99.3%. Variance proportion of aroma changes of lime leaves flavored green tea from day 0 to day 6 was 99.4%.

  16. Conjugate echoes of artifically injected electron beams detected optically by means of new image processing

    International Nuclear Information System (INIS)

    Hallinan, T.J.; Stenbaek-Nielsen, H.C.; Baldridge, J.; Winckler, J.; Malcolm, P.

    1990-01-01

    Following two upward injections of energetic electrons (38 keV and 26 keV) from the Echo 4 rocket-borne electron accelerator, artificial auroral streaks were detected by ground-based low-light-level television. They were delayed relative to the injections by 2.06 s and 2.42 s, respectively. The delays are only 4-5% longer than calculated using a dynamic model of the geomagnetic field. Other field models yielded shorter bounce times. Since the delays were in the inverse ratio of the relativistic velocities calculated for the nominal beam energies, it is concluded that the potential of the payload remained below 1 kV during 45 mA injections at an altitude of 210 km. The echo streaks showed little dispersion in either time or space, indicating that the portion of the beam returning to the northen hemisphere loss cone remained collimated and nearly monoenergetic. But there was a 70% loss in the return flux. A diligent search failed to locate similar echoes from the more powerful injections employed in the Echo 5 and Echo 7 rocket experiments, suggesting flux losses of at least 98% and 92%, respectively. The losses are thought to be due to pitch angle scattering out of the loss cone as the electrons traverse the equatorial region but could also be due to collective beam plasma interactions

  17. Recent advances using electron beam analysis to detect cuticular changes induced by air pollution

    International Nuclear Information System (INIS)

    Krause, C.R.

    1994-01-01

    Invisible or ''hidden injury'', terms from the earliest air quality literature, expressed the diagnostician's frustration in identifying abiotic disease symptoms. Direct visualization was not technically possible until the advent of electron beam analysis (EBA) hardware and software. Electron beam analysis, a combination of scanning electron microscopy (SEM) energy dispersive X-ray analysis (EDXA), and computer-controlled image processing (CCIP) is useful for detecting changes in the cuticle and adjacent cells due to common phytotoxicants. Artifacts, caused by improper specimen preparation, inherent in the high vacuum of SEM and use of hydrated plant samples, fill the literature. Unique methodologies are necessary to interpret the minute changes to plant surfaces caused by a variety of environmental stresses such as sulfur dioxide, ozone, acidic deposition, pesticide residues, NACl, etc. EBA was used to show: the progression of surface alterations that occur to stomata of hybrid poplar (Populus spp.) following exposure to SO 2 and O 3 ; between SO 2 -sensitive and SO 2 -tolerant clones of eastern white pine (Pinus strobus L.). CCIP was especially useful in determining that acidified rain or mist and O 3 do not physically erode existing epicuticular wax of red spruce (Picea rubens Sarg.) as previous literature stated. EBA was used to correlate field and laboratory data showing similar injury to epistomatal wax of red spruce. Improved field emission microscopy and EDXA that offer increased resolution with little sample preparation can provide opportunities to observe cuticular modifications not previously available. (orig.)

  18. High-Performance X-ray Detection in a New Analytical Electron Microscope

    Science.gov (United States)

    Lyman, C. E.; Goldstein, J. I.; Williams, D. B.; Ackland, D. W.; vonHarrach, S.; Nicholls, A. W.; Statham, P. J.

    1994-01-01

    X-ray detection by energy-dispersive spectrometry in the analytical electron microscope (AEM) is often limited by low collected X-ray intensity (P), modest peak-to-background (P/B) ratios, and limitations on total counting time (tau) due to specimen drift and contamination. A new AFM has been designed with maximization of P. P/B, and tau as the primary considerations. Maximization of P has been accomplished by employing a field-emission electron gun, X-ray detectors with high collection angles, high-speed beam blanking to allow only one photon into the detector at a time, and simultaneous collection from two detectors. P/B has been maximized by reducing extraneous background signals generated at the specimen holder, the polepieces and the detector collimator. The maximum practical tau has been increased by reducing specimen contamination and employing electronic drift correction. Performance improvments have been measured using the NIST standard Cr thin film. The 0-3 steradian solid angle of X-ray collection is the highest value available. The beam blanking scheme for X-ray detection provides 3-4 times greater throughput of X-rays at high count rates into a recorded spectrum than normal systems employing pulse-pileup rejection circuits. Simultaneous X-ray collection from two detectors allows the highest X-ray intensity yet recorded to be collected from the NIST Cr thin film. The measured P/B of 6300 is the highest level recorded for an AEM. In addition to collected X-ray intensity (cps/nA) and P/B measured on the standard Cr film, the product of these can be used as a figure-of-merit to evaluate instruments. Estimated minimum mass fraction (MMF) for Cr measured on the standard NIST Cr thin film is also proposed as a figure-of-merit for comparing X-ray detection in AEMs. Determinations here of the MMF of Cr detectable show at least a threefold improvement over previous instruments.

  19. Study on detection of electron beam irradiated food by ESR spectroscopy and comparison of the ESR spectrum of electron beams and γ-rays

    International Nuclear Information System (INIS)

    Li Weiming; Ha Yiming; Wang Feng

    2012-01-01

    The study was conducted to detect electron beam irradiated food by ESR spectroscopy. The white pepper powder, paprika powder, cumin powder and pistachios were used as test materials to study the feature changes of ESR spectrum and the relationship between ESR intensity and irradiation dose in different doses, the shape variation of ESR spectrum in γ-rays and electron beams in the same sample was also compared. The results showed that the ESR spectrum of 4 kinds of irradiated samples was obviously different before and after irradiation, the intensity of ESR signal increased with the increasing of the absorbed dose. The dose above 432 Gy could be detected in white pepper powder and pistachios, the dose above 875 Gy could be detected in paprika powder and cumin powder. The ESR intensity of all samples decreased during the storage time (200 d), even after 200 days the ESR method could also be used to detect whether or not the samples have been irradiated. The same dosage of y-rays and electron beams has no significant influence on the shape of ESR spectrum, however, the difference of irradiation mechanism caused slight impact on ESR intensity. The results could provide the technical basis for the application of ESR method in detecting electron beam irradiated food. (authors)

  20. Study on detection of electron beam irradiated food by ESR spectroscopy and comparison of the ESR spectrum of electron beams and γ-rays

    International Nuclear Information System (INIS)

    Li Weiming; Ha Yiming; Wang Feng

    2011-01-01

    The study was conducted to detect electron beam irradiated food by ESR spectroscopy. The white pepper powder, paprika powder, cumin powder and pistachios were used as test materials to study the feature changes of ESR spectrum and the relationship between ESR intensity and irradiation dose in different doses, the shape variation of ESR spectrum in γ-rays and electron beams in the same sample was also compared. The results showed that the ESR spectrum of 4 kinds of irradiated samples was obviously different before and after irradiation, the intensity of ESR signal increased with the increasing of the absorbed dose. The dose above 432 Gy could be detected in white pepper powder and pistachios, the dose above 875 Gy could be detected in paprika powder and cumin powder. The ESR intensity of all samples decreased during the storage time (200 d), even after 200 days the ESR method could also be used to detect whether or not the samples have been irradiated. The same dosage of γ-rays and electron beams has no significant influence on the shape of ESR spectrum, however, the difference of irradiation mechanism caused slight impact on ESR intensity. The results could provide the technical basis for the application of ESR method in detecting electron beam irradiated food. (authors)

  1. Detection of Off-Flavor in Catfish Using a Conducting Polymer Electronic-Nose Technology

    Directory of Open Access Journals (Sweden)

    Alphus D. Wilson

    2013-11-01

    Full Text Available The Aromascan A32S conducting polymer electronic nose was evaluated for the capability of detecting the presence of off-flavor malodorous compounds in catfish meat fillets to assess meat quality for potential merchantability. Sensor array outputs indicated that the aroma profiles of good-flavor (on-flavor and off-flavor fillets were strongly different as confirmed by a Principal Component Analysis (PCA and a Quality Factor value (QF > 7.9 indicating a significant difference at (P < 0.05. The A32S e-nose effectively discriminated between good-flavor and off-flavor catfish at high levels of accuracy (>90% and with relatively low rates (≤5% of unknown or indecisive determinations in three trials. This A32S e-nose instrument also was capable of detecting the incidence of mild off-flavor in fillets at levels lower than the threshold of human olfactory detection. Potential applications of e-nose technologies for pre- and post-harvest management of production and meat-quality downgrade problems associated with catfish off-flavor are discussed.

  2. Phosphorescent quantum dots/ethidium bromide nanohybrids based on photoinduced electron transfer for DNA detection.

    Science.gov (United States)

    Bi, Lin; Yu, Yuan-Hua

    2015-04-05

    Mercaptopropionic acid-capped Mn-doped ZnS quantum dots/ethidium bromide (EB) nanohybrids were constructed for photoinduced electron transfer (PIET) and then used as a room-temperature phosphorescence (RTP) probe for DNA detection. EB could quench the RTP of Mn-doped ZnS QDs by PIET, thereby forming Mn-doped ZnS QDs/EB nanohybrids and storing RTP. Meanwhile, EB could be inserted into DNA and EB could be competitively desorbed from the surface of Mn-doped ZnS QDs by DNA, thereby releasing the RTP of Mn-doped ZnS QDs. Based on this mechanism, a RTP sensor for DNA detection was developed. Under optimal conditions, the detection limit for DNA was 0.045 mg L(-1), the relative standard deviation was 1.7%, and the method linear ranged from 0.2 to 20 mg L(-1). The proposed method was applied to biological fluids, in which satisfactory results were obtained. Copyright © 2015 Elsevier B.V. All rights reserved.

  3. Noninvasive detection of coronary artery bypass graft patency by intravenous electron beam computed tomographic angiography.

    Science.gov (United States)

    Yamakami, Shoji; Toyama, Junji; Okamoto, Mitsuhiro; Matsushita, Toyoaki; Murakami, Yoshimasa; Ogata, Masaki; Ito, Shigenori; Fukutomi, Tatsuya; Okayama, Naotsuka; Itoh, Makoto

    2003-11-01

    This study evaluates the usefullness of intravenous electron beam computed tomographic angiography (EBA) for the detection of coronary artery bypass graft patency in 43 patients (33 men and 10 women, mean age, 65 years) who had coronary artery bypass graft surgery. EBA was performed a few days before selective bypass graft angiography (SGA). Forty axial cross-sections of angiographic images of the heart were acquired consecutively by an electrocardiographic trigger signal at 40% of the RR interval, which corresponds to the end-systolic phase. EBA data were reconstructed as a three-dimensional shaded surface display of the heart and bypass grafts. Detectability of the patency of bypass gratis was evaluated, taking selective angiographic images of the bypass grafts as a gold standard. One hundred and nine grafts (96%) out of 114 grafts were subjected to evaluation: 37 grafts were left internal mammary artery grafts (LIMA), 7 were right internal mammary artery grafts (RIMA), 6 were gastroepiploic artery grafts (GEA), 7 were free gastroepiploic artery grafts with venous drainage (free-GEA), 7 were radial artery grafts (RAG), and 45 were saphenous vein gratis (SVG). The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of EBA were 98%, 100%, 100%, 91%, and 98%, respectively. EBA sampled at the end-systolic period was determined to be useful for the detection of coronary artery bypass graft patency and occlusion.

  4. Single-step transepithelial ASLA (SCHWIND with mitomycin-C for the correction of high myopia: long term follow-up

    Directory of Open Access Journals (Sweden)

    Aslanides IM

    2014-12-01

    Full Text Available Ioannis M Aslanides, Panagiotis N Georgoudis, Vasilis D Selimis, Achyut N Mukherjee Emmetropia Mediterranean Eye Institute, Heraklion, Crete, Greece Purpose: We wanted to compare the outcomes of single-step modified transepithelial photorefractive keratectomy (tPRK termed a SCHWIND all surface laser ablation (ASLA versus conventional alcohol-assisted photorefractive keratectomy (PRK and laser-assisted in situ keratomileusis (LASIK for the correction of higher myopia of 6.00 diopters (D or more, in an area with high risk of haze due to high intensity of sunlight.Methods: We used a prospective interventional cohort with matched retrospective control groups. Patients with >6 D myopia and <3.5 D of astigmatism were included. All treatments were performed with the SCHWIND Amaris system using aspheric ablation profiles. Mitomycin C was used in all PRK and ASLA cases. Outcomes were postoperative refraction, visual acuity, stability, and complications. The follow-up period was up to 12 months.Results: In total, 101 eyes were included after exclusions. Mean preoperative spherical equivalent refraction was −7.9 D, −8.2 D, and −7.4 D in the ASLA (n=41, PRK (n=29, and LASIK (n=31 groups. Mean postoperative spherical equivalent at 12 months postoperatively was −0.1 (standard deviation [SD]: 0.34, −0.2 (SD: 0.59, and −0.08 (SD: 0.36 in the ASLA, PRK, and LASIK groups, with 91.4%, 85.7%, and 83.9% within 0.5 D of target, respectively. Refractive outcomes and regression at 12 months did not vary among groups (P>0.05. Mean logMAR (logarithm of the minimum angle of resolution uncorrected distance visual acuity at 12 months was 0.00 (SD: 0.05, 0.06 (SD: 0.1, and 0.05 (SD: 0.09 in the ASLA, PRK, and LASIK groups, with significantly better vision in the tPRK group versus LASIK (P=0.01 and PRK (P=0.01 groups.Conclusion: ASLA (SCHWIND tPRK with mitomycin C for high myopia demonstrates comparable refractive outcomes to LASIK and PRK, with relatively

  5. Using single-step genomic best linear unbiased predictor to enhance the mitigation of seasonal losses due to heat stress in pigs.

    Science.gov (United States)

    Fragomeni, B O; Lourenco, D A L; Tsuruta, S; Bradford, H L; Gray, K A; Huang, Y; Misztal, I

    2016-12-01

    The purposes of this study were to analyze the impact of seasonal losses due to heat stress in pigs from different breeds raised in different environments and to evaluate the accuracy improvement from adding genomic information to genetic evaluations. Data were available for 2 different swine populations: purebred Duroc animals raised in Texas and North Carolina and commercial crosses of Duroc and F females (Landrace × Large White) raised in Missouri and North Carolina; pedigrees provided links for animals from different states. Pedigree information was available for 553,442 animals, of which 8,232 pure breeds were genotyped. Traits were BW at 170 d for purebred animals and HCW for crossbred animals. Analyses were done with an animal model as either single- or 2-trait models using phenotypes measured in different states as separate traits. Additionally, reaction norm models were fitted for 1 or 2 traits using heat load index as a covariable. Heat load was calculated as temperature-humidity index greater than 70 and was averaged over 30 d prior to data collection. Variance components were estimated with average information REML, and EBV and genomic EBV (GEBV) with BLUP or single-step genomic BLUP (ssGBLUP). Validation was assessed for 146 genotyped sires with progeny in the last generation. Accuracy was calculated as a correlation between EBV and GEBV using reduced data (all animals, except the last generation) and using complete data. Heritability estimates for purebred animals were similar across states (varying from 0.23 to 0.26), and reaction norm models did not show evidence of a heat stress effect. Genetic correlations between states for heat loads were always strong (>0.91). For crossbred animals, no differences in heritability were found in single- or 2-trait analysis (from 0.17 to 0.18), and genetic correlations between states were moderate (0.43). In the reaction norm for crossbreeds, heritabilities ranged from 0.15 to 0.30 and genetic correlations

  6. Improving detection of familial hypercholesterolaemia in primary care using electronic audit and nurse‐led clinics

    Science.gov (United States)

    Neely, Dermot; Humphries, Steve E.; Saunders, Tanya; Gray, Val; Gordon, Louise; Payne, Jules; Carter, Slade; Neuwirth, Clare; Rees, Alan; Gallagher, Hazel

    2015-01-01

    Abstract Rationale, aims and objectives In the UK fewer than 15% of familial hypercholesterolemia (FH) cases are diagnosed, representing a major gap in coronary heart disease prevention. We wished to support primary care doctors within the Medway Clinical Commissioning Group (CCG) to implement NICE guidance (CG71) and consider the possibility of FH in adults who have raised total cholesterol concentrations, thereby improving the detection of people with FH. Methods Utilizing clinical decision support software (Audit+) we developed an FH Audit Tool and implemented a systematic audit of electronic medical records within GP practices, first identifying all patients diagnosed with FH or possible FH and next electronically flagging patients with a recorded total cholesterol of >7.5 mmol L−1 or LDL‐C > 4.9 mmol L−1 (in adults), for further assessment. After a 2‐year period, a nurse‐led clinic was introduced to screen more intensely for new FH index cases. We evaluated if these interventions increased the prevalence of FH closer to the expected prevalence from epidemiological studies. Results The baseline prevalence of FH within Medway CCG was 0.13% (1 in 750 persons). After 2 years, the recorded prevalence of diagnosed FH increased by 0.09% to 0.22% (1 in 450 persons). The nurse advisor programme ran for 9 months (October 2013–July 2014) and during this time, the recorded prevalence of patients diagnosed with FH increased to 0.28% (1 in 357 persons) and the prevalence of patients ‘at risk and unscreened’ reduced from 0.58% to 0.14%. Conclusions Our study shows that two simple interventions increased the detection of FH. This systematic yet simple electronic case‐finding programme with nurse‐led review allowed the identification of new index cases, more than doubling the recorded prevalence of detected disease to 1 in 357 (0.28%). This study shows that primary care has an important role in identifying patients with this condition. PMID

  7. Improving detection of familial hypercholesterolaemia in primary care using electronic audit and nurse-led clinics.

    Science.gov (United States)

    Green, Peter; Neely, Dermot; Humphries, Steve E

    2016-06-01

    In the UK fewer than 15% of familial hypercholesterolemia (FH) cases are diagnosed, representing a major gap in coronary heart disease prevention. We wished to support primary care doctors within the Medway Clinical Commissioning Group (CCG) to implement NICE guidance (CG71) and consider the possibility of FH in adults who have raised total cholesterol concentrations, thereby improving the detection of people with FH. Utilizing clinical decision support software (Audit+) we developed an FH Audit Tool and implemented a systematic audit of electronic medical records within GP practices, first identifying all patients diagnosed with FH or possible FH and next electronically flagging patients with a recorded total cholesterol of >7.5 mmol L(-1) or LDL-C > 4.9 mmol L(-1) (in adults), for further assessment. After a 2-year period, a nurse-led clinic was introduced to screen more intensely for new FH index cases. We evaluated if these interventions increased the prevalence of FH closer to the expected prevalence from epidemiological studies. The baseline prevalence of FH within Medway CCG was 0.13% (1 in 750 persons). After 2 years, the recorded prevalence of diagnosed FH increased by 0.09% to 0.22% (1 in 450 persons). The nurse advisor programme ran for 9 months (October 2013-July 2014) and during this time, the recorded prevalence of patients diagnosed with FH increased to 0.28% (1 in 357 persons) and the prevalence of patients 'at risk and unscreened' reduced from 0.58% to 0.14%. Our study shows that two simple interventions increased the detection of FH. This systematic yet simple electronic case-finding programme with nurse-led review allowed the identification of new index cases, more than doubling the recorded prevalence of detected disease to 1 in 357 (0.28%). This study shows that primary care has an important role in identifying patients with this condition. © 2015 The Authors. Journal of Evaluation in Clinical Practice published by John Wiley

  8. Quantitative detection of plasma-generated radicals in liquids by electron paramagnetic resonance spectroscopy

    International Nuclear Information System (INIS)

    Tresp, H; Hammer, M U; Winter, J; Reuter, S; Weltmann, K-D

    2013-01-01

    In this paper the qualitative and quantitative detection of oxygen radicals in liquids after plasma treatment with an atmospheric pressure argon plasma jet by electron paramagnetic resonance spectroscopy is investigated. Absolute values for · OH and O 2 ·- radical concentration and their net production rate in plasma-treated liquids are determined without the use of additional scavenging chemicals such as superoxide dismutase (SOD) or mannitol (D-MAN). The main oxygen-centred radical generation in PBS was found to originate from the superoxide radical. It is shown that hidden parameters such as the manufacturer of chemical components could have a big influence on the comparability and reproducibility of the results. Finally, the effect of a shielding gas device for the investigated plasma jet with a shielding gas composition of varying oxygen-to-nitrogen ratio on radical generation after plasma treatment of phosphate-buffered saline solution was investigated. (paper)

  9. Fuzzy Pattern Classification Based Detection of Faulty Electronic Fuel Control (EFC Valves Used in Diesel Engines

    Directory of Open Access Journals (Sweden)

    Umut Tugsal

    2014-05-01

    Full Text Available In this paper, we develop mathematical models of a rotary Electronic Fuel Control (EFC valve used in a Diesel engine based on dynamic performance test data and system identification methodology in order to detect the faulty EFC valves. The model takes into account the dynamics of the electrical and mechanical portions of the EFC valves. A recursive least squares (RLS type system identification methodology has been utilized to determine the transfer functions of the different types of EFC valves that were investigated in this study. Both in frequency domain and time domain methods have been utilized for this purpose. Based on the characteristic patterns exhibited by the EFC valves, a fuzzy logic based pattern classification method was utilized to evaluate the residuals and identify faulty EFC valves from good ones. The developed methodology has been shown to provide robust diagnostics for a wide range of EFC valves.

  10. Towards improving the detection limit of electron paramagnetic resonance (EPR) dosimetry of drywall (wallboard)

    Energy Technology Data Exchange (ETDEWEB)

    Mistry, R.; Thompson, J.W. [Dept. of Medical Physics and Applied Radiation Sciences, McMaster Univ., Hamilton, Ontario (Canada); Rink, W.J. [School of Geography and Earth Sciences, McMaster Univ., Hamilton, Ontario (Canada); Boreham, D. [Dept. of Medical Physics and Applied Radiation Sciences, McMaster Univ., Hamilton, Ontario (Canada)

    2009-07-01

    The intensity of the electron paramagnetic resonance (EPR) line corresponding to the carbonate free radical (CO{sub 3}{sup -}) in gypsum (CaSO{sub 4}{center_dot}2H{sub 2}O) drywall was previously shown to be proportional to absorbed dose. Heating irradiated drywall reduces the radiosensitive signal of the CO{sub 3}{sup -} radical. The response of the CO{sub 3}{sup -} EPR line to heat treatments is being studied in order to determine a background for an arbitrary drywall sample. Ultimately this is expected to improve the precision of dose measurements with drywall and to reduce the detection limit. Controlled heating of irradiated drywall was performed at temperatures between 50{sup o}C and 100{sup o}C. Although higher temperatures reduce the radiosensitive signal rapidly, the non-radiosensitive EPR signals are affected dramatically as well, presumably due to a phrase change from gypsum to plaster of Paris to anhydrite. (author)

  11. Determination of nitrosourea compounds in brain tissue by gas chromatography and electron capture detection.

    Science.gov (United States)

    Hassenbusch, S J; Colvin, O M; Anderson, J H

    1995-07-01

    A relatively simple, high-sensitivity gas chromatographic assay is described for nitrosourea compounds, such as BCNU [1,3-bis(2-chloroethyl)-1-nitrosourea] and MeCCNU [1-(2-chloroethyl)-3-(trans-4-methylcyclohexyl)-1-nitrosourea], in small biopsy samples of brain and other tissues. After extraction with ethyl acetate, secondary amines in BCNU and MeCCNU are derivatized with trifluoroacetic anhydride. Compounds are separated and quantitated by gas chromatography using a capillary column with temperature programming and an electron capture detector. Standard curves of BCNU indicate a coefficient of variance of 0.066 +/- 0.018, a correlation coefficient of 0.929, and an extraction efficiency from whole brain of 68% with a minimum detectable amount of 20 ng in 5-10 mg samples. The assay has been facile and sensitive in over 1000 brain biopsy specimens after intravenous and intraarterial infusions of BCNU.

  12. Detection of X-ray fluorescence of light elements by electron counting in a low-pressure gaseous electron multiplier

    International Nuclear Information System (INIS)

    Pansky, A.; Breskin, A.; Chechik, R.; Malamud, G.

    1992-12-01

    Ionization electrons deposited by soft X-rays in a low pressure (10 Torr) gas medium are efficiently counted by a multistage electron multiplier, providing an accurate measurement of the X-ray photon energy. Energy resolution of 56-28% FWHM were measured for X-rays of 110-676 eV, recording electrical induced charges or visible photons emitted during the avalanche process. It is demonstrated that a combined analysis of the number of electron trail length of an event, provides a powerful and competitive way of resolving ultra soft X-rays. We present the experimental technique, discuss the advantages and limitations of the Primary Electron Counter, and suggest ways to improve its performances. (authors)

  13. On-ground detection of an electron-positron annihilation line from thunderclouds.

    Science.gov (United States)

    Umemoto, D; Tsuchiya, H; Enoto, T; Yamada, S; Yuasa, T; Kawaharada, M; Kitaguchi, T; Nakazawa, K; Kokubun, M; Kato, H; Okano, M; Tamagawa, T; Makishima, K

    2016-02-01

    Thunderclouds can produce bremsstrahlung gamma-ray emission, and sometimes even positrons. At 00:27:00 (UT) on 13 January 2012, an intense burst of gamma rays from a thundercloud was detected by the GROWTH experiment, located in Japan, facing the Sea of Japan. The event started with a sharp gamma-ray flash with a duration of gamma-ray emission lasting for ∼60 s. The spectrum of this prolonged emission reached ∼10 MeV, and contained a distinct line emission at 508±3(stat.)±5(sys.) keV, to be identified with an electron-positron annihilation line. The line was narrow within the instrumental energy resolution (∼80keV), and contained 520±50 photons which amounted to ∼10% of the total signal photons of 5340±190 detected over 0.1-10 MeV. As a result, the line equivalent width reached 280±40 keV, which implies a nontrivial result. The result suggests that a downward positron beam produced both the continuum and the line photons.

  14. Detection of irradiation treatment in crustacea by electron spin resonance (ESR) spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Stewart, E.M. [Queen`s Univ., Belfast, Northern Ireland (United Kingdom). Dept. of Food Science; Stevenson, M.H. [Queen`s Univ., Belfast, Northern Ireland (United Kingdom). Dept. of Food Science]|[Department of Agriculture for Northern Ireland, Belfast (United Kingdom); Gray, R. [Department of Agriculture for Northern Ireland, Belfast (United Kingdom)

    1996-12-31

    When the Food (Control of Irradiation) Regulations 1990 came into force in the United Kingdom in January 1991 they included provision for the irradiation of Crustacea to an overall average dose of 3 kGy. The treatment of Crustacea with ionising radiation would reduce numbers of potential pathogens and spoilage organisms thus giving a microbiologically safer product with a longer shelf-life at chill temperatures. At present the process is being used in countries such as France and The Netherlands for the decontamination/shelf-life extension of shrimp. Therefore, as for other food products such as poultry, liquid whole egg and fruit, which are also treated with ionising radiation, it is desirable that a suitable test should be available to help in the control of the irradiation process. One such detection method which has been applied to irradiated Crustacea is that of electron spin resonance (ESR) spectroscopy due to the fact that the rigid exoskeleton has a relatively high dry matter so free radicals produced by ionising irradiation can be trapped and are, therefore, sufficiently stable to be detected. (author).

  15. Detection of irradiation treatment in crustacea by electron spin resonance (ESR) spectroscopy

    International Nuclear Information System (INIS)

    Stewart, E.M.; Gray, R.

    1996-01-01

    When the Food (Control of Irradiation) Regulations 1990 came into force in the United Kingdom in January 1991 they included provision for the irradiation of Crustacea to an overall average dose of 3 kGy. The treatment of Crustacea with ionising radiation would reduce numbers of potential pathogens and spoilage organisms thus giving a microbiologically safer product with a longer shelf-life at chill temperatures. At present the process is being used in countries such as France and The Netherlands for the decontamination/shelf-life extension of shrimp. Therefore, as for other food products such as poultry, liquid whole egg and fruit, which are also treated with ionising radiation, it is desirable that a suitable test should be available to help in the control of the irradiation process. One such detection method which has been applied to irradiated Crustacea is that of electron spin resonance (ESR) spectroscopy due to the fact that the rigid exoskeleton has a relatively high dry matter so free radicals produced by ionising irradiation can be trapped and are, therefore, sufficiently stable to be detected. (author)

  16. Electrical detection of spin transport in Si two-dimensional electron gas systems

    Science.gov (United States)

    Chang, Li-Te; Fischer, Inga Anita; Tang, Jianshi; Wang, Chiu-Yen; Yu, Guoqiang; Fan, Yabin; Murata, Koichi; Nie, Tianxiao; Oehme, Michael; Schulze, Jörg; Wang, Kang L.

    2016-09-01

    Spin transport in a semiconductor-based two-dimensional electron gas (2DEG) system has been attractive in spintronics for more than ten years. The inherent advantages of high-mobility channel and enhanced spin-orbital interaction promise a long spin diffusion length and efficient spin manipulation, which are essential for the application of spintronics devices. However, the difficulty of making high-quality ferromagnetic (FM) contacts to the buried 2DEG channel in the heterostructure systems limits the potential developments in functional devices. In this paper, we experimentally demonstrate electrical detection of spin transport in a high-mobility 2DEG system using FM Mn-germanosilicide (Mn(Si0.7Ge0.3)x) end contacts, which is the first report of spin injection and detection in a 2DEG confined in a Si/SiGe modulation doped quantum well structure (MODQW). The extracted spin diffusion length and lifetime are l sf = 4.5 μm and {τ }{{s}}=16 {{ns}} at 1.9 K respectively. Our results provide a promising approach for spin injection into 2DEG system in the Si-based MODQW, which may lead to innovative spintronic applications such as spin-based transistor, logic, and memory devices.

  17. Early detection of fungal contamination on green coffee by a MOX sensors based Electronic Nose

    International Nuclear Information System (INIS)

    Sberveglieri, V.; Pulvirenti, A.; Fava, P.; Concina, I.; Falasconi, M.; Gobbi, E.

    2011-01-01

    Fungal growth can occur on green coffee beans along all the distribution chain, eventually bringing on health hazards to consumers, because of the production of toxic metabolites (mycotoxins). Besides, the sensorial contamination due to volatiles by-products of fungal metabolism could cause defects on coffee also after roasting. Therefore, it is necessary to devise strategies to detect and quantify fungal infection and toxin production at early stages of the food chain. One of the most promising techniques is the analysis of volatile compounds in the headspace gas surrounding the samples. The aim of this work was to verify the ability of the Electronic Nose (EN EOS 835 ) to early detect the microbial contamination of Arabica green coffee. This EN is equipped with Metal Oxide Semiconductor sensor array. Gas chromatography coupled to mass spectrometry (GC-MS) analysis of the static headspace of non-contaminated Arabica green coffee samples was carried out to confirm the EN ability to provide satisfactory indications about the presence of contamination.

  18. Detecting stray microwaves and nonequilibrium quasiparticles in thin films by single-electron tunneling

    Science.gov (United States)

    Saira, Olli-Pentti; Maisi, Ville; Kemppinen, Antti; Möttönen, Mikko; Pekola, Jukka

    2013-03-01

    Superconducting thin films and tunnel junctions are the building blocks of many state-of-the-art technologies related to quantum information processing, microwave detection, and electronic amplification. These devices operate at millikelvin temperatures, and - in a naive picture - their fidelity metrics are expected to improve as the temperature is lowered. However, very often one finds in the experiment that the device performance levels off around 100-150 mK. In my presentation, I will address three common physical mechanisms that can cause such saturation: stray microwaves, nonequilibrium quasiparticles, and sub-gap quasiparticle states. The new experimental data I will present is based on a series of studies on quasiparticle transport in Coulomb-blockaded normal-insulator-superconductor tunnel junction devices. We have used a capacitively coupled SET electrometer to detect individual quasiparticle tunneling events in real time. We demonstrate the following record-low values for thin film aluminum: quasiparticle density nqp < 0 . 033 / μm3 , normalized density of sub-gap quasiparticle states (Dynes parameter) γ < 1 . 6 ×10-7 . I will also discuss some sample stage and chip designs that improve microwave shielding.

  19. Detecting Fermi-level shifts by Auger electron spectroscopy in Si and GaAs

    Science.gov (United States)

    Debehets, J.; Homm, P.; Menghini, M.; Chambers, S. A.; Marchiori, C.; Heyns, M.; Locquet, J. P.; Seo, J. W.

    2018-05-01

    In this paper, changes in surface Fermi-level of Si and GaAs, caused by doping and cleaning, are investigated by Auger electron spectroscopy. Based on the Auger voltage contrast, we compared the Auger transition peak energy but with higher accuracy by using a more accurate analyzer and an improved peak position determination method. For silicon, a peak shift as large as 0.46 eV was detected when comparing a cleaned p-type and n-type wafer, which corresponds rather well with the theoretical difference in Fermi-levels. If no cleaning was applied, the peak position did not differ significantly for both wafer types, indicating Fermi-level pinning in the band gap. For GaAs, peak shifts were detected after cleaning with HF and (NH4)2S-solutions in an inert atmosphere (N2-gas). Although the (NH4)2S-cleaning in N2 is very efficient in removing the oxygen from the surface, the observed Ga- and As-peak shifts are smaller than those obtained after the HF-cleaning. It is shown that the magnitude of the shift is related to the surface composition. After Si-deposition on the (NH4)2S-cleaned surface, the Fermi-level shifts back to a similar position as observed for an as-received wafer, indicating that this combination is not successful in unpinning the Fermi-level of GaAs.

  20. FPGA based phase detection technique for electron density measurement in SST-1 tokamak

    International Nuclear Information System (INIS)

    Pramila; Mandaliya, Hitesh; Rajpal, Rachana; Kaur, Rajwinder

    2016-01-01

    A multi-channel signal-conditioning and phase-detection concept is implemented in the prototype design using the high-precision OPAMP, high-speed comparators, high Q filters, high-density FPGA (Field Programmable Gate array), 10 MHz parallel-multiplying DACs (Digital to Analog Converter), etc. The complete digital-logic for the phase-detection is implemented inside the logic cells of FPGA using VHDL code, with high speed 100 MHz clock generated from Digital Clock Manager (DCM), which is used to measure the time elapsed between zero crossings of the two signals coming from reference and probe paths of the diagnostics. The logic is implemented to measure either leading or lagging phase and also to accumulate the total phase difference throughout the shot duration with the maximum value of accumulated phase of 5760 (16 cycles × 360°) degree and a resolution of 3.6 °. A precision high speed and high bandwidth (80 MHz) operational amplifiers are used as the front end-electronics component for conditioning the high-frequency (1 MHz) and low amplitude signal (μV). The hardware detail, implementation concept in FPGA and testing results will be presented in the paper.

  1. Detecting the Use of Intentionally Transmitting Personal Electronic Devices Onboard Commercial Aircraft

    Science.gov (United States)

    Woods, Randy; Ely, Jay J.; Vahala, Linda

    2003-01-01

    The need to detect unauthorized usage of intentionally transmitting portable electronic devices (PEDs) onboard commercial aircraft is growing, while still allowing passengers to use selected unintentionally transmitting devices, such as laptop computers and CD players during non-critical stages of flight. The following paper presents an installed system for detecting PEDs over multiple frequency bands. Additionally, the advantages of a fixed verses mobile system are discussed. While data is presented to cover the frequency range of 20 MHz to 6.5 GHz, special attention was given to the Cellular/PCS bands as well as Bluetooth and the FRS radio bands. Measurement data from both the semi-anechoic and reverberation chambers are then analyzed and correlated with data collected onboard a commercial aircraft to determine the dominant mode of coupling inside the passenger cabin of the aircraft versus distance from the source. As a final check of system feasibility, several PEDs transmission signatures were recorded and compared with the expected levels.

  2. Design of a portable electronic nose for real-fake detection of liquors

    Science.gov (United States)

    Qi, Pei-Feng; Zeng, Ming; Li, Zhi-Hua; Sun, Biao; Meng, Qing-Hao

    2017-09-01

    Portability is a major issue that influences the practical application of electronic noses (e-noses). For liquors detection, an e-nose must preprocess the liquid samples (e.g., using evaporation and thermal desorption), which makes the portable design even more difficult. To realize convenient and rapid detection of liquors, we designed a portable e-nose platform that consists of hardware and software systems. The hardware system contains an evaporation/sampling module, a reaction module, a control/data acquisition and analysis module, and a power module. The software system provides a user-friendly interface and can achieve automatic sampling and data processing. This e-nose platform has been applied to the real-fake recognition of Chinese liquors. Through parameter optimization of a one-class support vector machine classifier, the error rate of the negative samples is greatly reduced, and the overall recognition accuracy is improved. The results validated the feasibility of the designed portable e-nose platform.

  3. FPGA based phase detection technique for electron density measurement in SST-1 tokamak

    Energy Technology Data Exchange (ETDEWEB)

    Pramila, E-mail: pramila@ipr.res.in; Mandaliya, Hitesh; Rajpal, Rachana; Kaur, Rajwinder

    2016-11-15

    A multi-channel signal-conditioning and phase-detection concept is implemented in the prototype design using the high-precision OPAMP, high-speed comparators, high Q filters, high-density FPGA (Field Programmable Gate array), 10 MHz parallel-multiplying DACs (Digital to Analog Converter), etc. The complete digital-logic for the phase-detection is implemented inside the logic cells of FPGA using VHDL code, with high speed 100 MHz clock generated from Digital Clock Manager (DCM), which is used to measure the time elapsed between zero crossings of the two signals coming from reference and probe paths of the diagnostics. The logic is implemented to measure either leading or lagging phase and also to accumulate the total phase difference throughout the shot duration with the maximum value of accumulated phase of 5760 (16 cycles × 360°) degree and a resolution of 3.6 °. A precision high speed and high bandwidth (80 MHz) operational amplifiers are used as the front end-electronics component for conditioning the high-frequency (1 MHz) and low amplitude signal (μV). The hardware detail, implementation concept in FPGA and testing results will be presented in the paper.

  4. Detection of the electronic structure of iron-(iii)-oxo oligomers forming in aqueous solutions.

    Science.gov (United States)

    Seidel, Robert; Kraffert, Katrin; Kabelitz, Anke; Pohl, Marvin N; Kraehnert, Ralph; Emmerling, Franziska; Winter, Bernd

    2017-12-13

    The nature of the small iron-oxo oligomers in iron-(iii) aqueous solutions has a determining effect on the chemical processes that govern the formation of nanoparticles in aqueous phase. Here we report on a liquid-jet photoelectron-spectroscopy experiment for the investigation of the electronic structure of the occurring iron-oxo oligomers in FeCl 3 aqueous solutions. The only iron species in the as-prepared 0.75 M solution are Fe 3+ monomers. Addition of NaOH initiates Fe 3+ hydrolysis which is followed by the formation of iron-oxo oligomers. At small enough NaOH concentrations, corresponding to approximately [OH]/[Fe] = 0.2-0.25 ratio, the iron oligomers can be stabilized for several hours without engaging in further aggregation. Here, we apply a combination of non-resonant as well as iron 2p and oxygen 1s resonant photoelectron spectroscopy from a liquid microjet to detect the electronic structure of the occurring species. Specifically, the oxygen 1s partial electron yield X-ray absorption (PEY-XA) spectra are found to exhibit a peak well below the onset of liquid water and OH - (aq) absorption. The iron 2p absorption gives rise to signal centered between the main absorption bands typical for aqueous Fe 3+ . Absorption bands in both PEY-XA spectra are found to correlate with an enhanced photoelectron peak near 20 eV binding energy, which demonstrates the sensitivity of resonant photoelectron (RPE) spectroscopy to mixing between iron and ligand orbitals. These various signals from the iron-oxo oligomers exhibit maximum intensity at [OH]/[Fe] = 0.25 ratio. For the same ratio, we observe changes in the pH as well as in complementary Raman spectra, which can be assigned to the transition from monomeric to oligomeric species. At approximately [OH]/[Fe] = 0.3 we begin to observe particles larger than 1 nm in radius, detected by small-angle X-ray scattering.

  5. Single-step green synthesis and characterization of gold-conjugated polyphenol nanoparticles with antioxidant and biological activities

    Directory of Open Access Journals (Sweden)

    Sanna V

    2014-10-01

    Full Text Available Vanna Sanna,1,2 Nicolino Pala,1 Giuseppina Dessì,1 Paola Manconi,1 Alberto Mariani,1 Sonia Dedola,3 Mauro Rassu,3 Claudia Crosio,3 Ciro Iaccarino,3 Mario Sechi1,2 1Department of Chemistry and Pharmacy, University of Sassari, Sassari, Italy; 2Laboratory of Nanomedicine, Department of Chemistry and Pharmacy, University of Sassari, c/o Porto Conte Ricerche, Tramariglio, Alghero, Italy; 3Department of Biomedical Sciences, University of Sassari, Sassari, Italy Background: Gold nanoparticles (GNPs are likely to provide an attractive platform for combining a variety of biophysicochemical properties into a unified nanodevice with great therapeutic potential. In this study we investigated the capabilities of three different natural polyphenols, epigallocatechin-3-gallate (EGCG, resveratrol (RSV, and fisetin (FS, to allow synergistic chemical reduction of gold salts to GNPs and stabilization in a single-step green process. Moreover, antioxidant properties of the nanosystems, as well as preliminary antiproliferative activity and apoptotic process investigation of model EGCG-GNPs on stable clones of neuroblastoma SH-SY5Y cells expressing CFP-DEVD-YFP reporter, were examined. Methods: The GNPs were characterized by physicochemical techniques, polyphenol content, and in vitro stability. The antioxidant activity of the GNPs was also determined by 2,2-diphenyl-1-picrylhydrazyl (DPPH and 2,2'-azinobis(3-ethylbenzothiazoline-6-sulfonic acid cation (ABTS radical-scavenging assays. Stable clones of neuronal SH-SY5Y-CFP-DEVD-YFP were generated and characterized, and cell viability after treatment with EGCG-GNPs was assessed after 72 hours through a 3(4,5-dimethylthiazol-2yl-5-(3-carboxymethoxyphenyl-2-(4-sulfophenyl-2H-tetrazolium assay. Activation of the apoptotic pathways was also investigated by Western blot analysis. Results: With a diameter in the size range of 10–25 nm, the obtained nanoparticles (NPs were found to contain 2.71%, 3.23%, and 5.47% of EGCG

  6. DNA comet assay as a rapid detection method of irradiated bovine meat by electron beam

    International Nuclear Information System (INIS)

    Marin-Huachaca, Nelida Simona; Villavicencio, Anna Lucia C.H.

    2001-01-01

    Full text: Introduction: The presence in food of pathogenic microorganisms, such as Salmonella species, Escherichia coli 0157:H7, Listeria Monocytogenes or Yersinia enterolitica, is a problem of growing concern to public health authorities all over the world. Thus, irradiation of certain prepackaged meat products such as ground beef, minced meat, and hamburgers may help in controlling meatborne pathogens and parasites. Pathogenic microorganisms and parasites in meat products, which are commonly consumed raw, are of particular importance, Up to now, only electron-beam accelerators and gamma-ray cells have been used for commercial applications. At the international conference on 'The Acceptance, Control of, and Trade in Irradiated Food', it was recommended that governments should encourage research into detection methods (Anon, 1989), Already five international standards are available to food control agencies. A number of physical, chemical, and biological techniques of detection of irradiated foods have been discussed in the literature. A rapid and inexpensive screening test employing DNA Comet Assay to identify radiation treatment of food has been described by Cerda et al. (1997). This method is restricted to foods that have not been subjected to heat or other treatments, which also induce DNA fragmentation. Advantages are its simplicity, low cost and speed of measurement. This method was proposed to the European Committee for Standardization (CEN) as a screening protocol (presumptive) and not as a proof (definitive). The DNA comet assay have been yielded good results with chicken, pork, fish meat, exotic meat, hamburgers, fruits and cereals. In this work we studied a DNA fragmentation of bovine meat irradiated by electron beam. Experimental: Bovine meat was purchased in local shops in Sao Paulo. Irradiation was performed with electron beam of accelerator facility of Radiation Dynamics Inc., USA (E=1,5 MeV, l=25 mA). The irradiation doses were 3,5; 4,5, 5,5, and 7

  7. A new method to measure and increase the detection efficiency of a microchannel plate for 100 keV electrons

    International Nuclear Information System (INIS)

    Tornow, R.P.

    1990-01-01

    A new method is described which permits measurement of efficiency of a microchannel plate (MCP) simply by tracing the output current pulse in the saturated mode. The dependence of the detection efficiency on the gain of the input stages of a detector is calculated and the result is applied to a MCP. Furthermore, an enhancement of the detection efficiency of a MCP is presented for 100 keV electrons up to more than 90% by means of the field-enhanced secondary electron emission. (author)

  8. Online hyphenation of extraction, Sephadex LH-20 column chromatography, and high-speed countercurrent chromatography: A highly efficient strategy for the preparative separation of andrographolide from Andrographis paniculata in a single step.

    Science.gov (United States)

    Zhang, Ying-Qi; Wang, Shan-Shan; Han, Chao; Xu, Jin-Fang; Luo, Jian-Guang; Kong, Ling-Yi

    2017-12-01

    A novel isolation strategy, online hyphenation of ultrasonic extraction, Sephadex LH-20 column chromatography combined with high-speed countercurrent chromatography, was developed for pure compounds extraction and purification. Andrographolide from Andrographis paniculata was achieved only in a single step purification protocol via the present strategy. The crude powder was ultrasonic extracted and extraction was pumped into Sephadex LH-20 column directly to cut the nontarget fractions followed by the second-dimensional high-speed countercurrent chromatography, hyphenated by a six-port valve equipped at the post-end of Sephadex LH-20 column, for the final purification. The results yielded andrographolide with the amount of 1.02 mg and a purity of 98.5% in a single step, indicating that the present method is effective to harvest target compound from medicinal plant. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. Detection of electron magnetic circular dichroism signals under zone axial diffraction geometry

    Energy Technology Data Exchange (ETDEWEB)

    Song, Dongsheng [National Center for Electron Microscopy in Beijing, Key Laboratory of Advanced Materials (MOE) and The State Key Laboratory of New Ceramics and Fine Processing, School of Materials Science and Engineering, Tsinghua University, Beijing 100084 (China); Rusz, Jan [Department of Physics and Astronomy, Uppsala University, Box 516, S-751 20 Uppsala (Sweden); Cai, Jianwang [Beijing National Laboratory for Condensed Matter Physics, Institute of Physics, Chinese Academy of Sciences, Beijing 100190 (China); Zhu, Jing, E-mail: jzhu@mail.tsinghua.edu.cn [National Center for Electron Microscopy in Beijing, Key Laboratory of Advanced Materials (MOE) and The State Key Laboratory of New Ceramics and Fine Processing, School of Materials Science and Engineering, Tsinghua University, Beijing 100084 (China)

    2016-10-15

    EMCD (electron magnetic circular dichroism) technique provides us a new opportunity to explore magnetic properties in the transmission electron microscope. However, specific diffraction geometry is the major limitation. Only the two-beam and three-beam case are demonstrated in the experiments until now. Here, we present the more general case of zone axial (ZA) diffraction geometry through which the EMCD signals can be detected even with the very strong sensitivity to dynamical diffraction conditions. Our detailed calculations and well-controlled diffraction conditions lead to experiments in agreement with theory. The effect of dynamical diffraction conditions on EMCD signals are discussed both in theory and experiments. Moreover, with the detailed analysis of dynamical diffraction effects, we experimentally obtain the separate EMCD signals for each crystallographic site in Y{sub 3}Fe{sub 5}O{sub 12}, which is also applicable for other materials and cannot be achieved by site-specific EMCD and XMCD technique directly. Our work extends application of more general diffraction geometries and will further promote the development of EMCD technique. - Highlights: • The zone axial (ZA) diffraction geometry is presented for EMCD technique. • The detailed calculations for EMCD signals under ZA case are conducted. • The EMCD signals are obtained under the ZA case in the experiments. • The effect of dynamical effect on EMCD signals under ZA case is discussed. • Site-specific EMCD signals of Fe in Y{sub 3}Fe{sub 5}O{sub 12} are obtained by specific ZA conditions.

  10. Detection of actinides with an electron accelerator by active photoneutron interrogation measurements

    International Nuclear Information System (INIS)

    Sari, A.; Carrel, F.; Gmar, M.; Laine, F.; Normand, S.; Lyoussi, A.

    2012-01-01

    The solution for management of a nuclear waste package is chosen according to its radiological characteristics. One of the most important of these features is the α-activity which is due to actinides ( 235 U, 238 U, 239 Pu, etc.) If non-destructive passive methods are not sufficient to quantify the latter, non-destructive active methods based on the fission process represent a solution of interest. First, these methods consist in irradiating a package in order to induce fission reactions on the actinides, and then, to detect the prompt and delayed particles which are emitted following these reactions. Our aim is to conduct neutron interrogation measurements on nuclear waste packages using an electron accelerator as a photoneutron generator. One of the main interests of this approach is that the intensity of the neutron flux can be one or two orders of magnitude higher than the one delivered by a deuterium-tritium generator. With the objective of improving nuclear waste characterization, the development of this method could enable the integration of three complementary techniques on a single measurement cell (active neutron interrogation, active photon interrogation, and high-energy imaging). In this paper, simulation and experimental results are presented. A simulation study using MCNPX has been conducted in order to determine the characteristics of the photoneutron flux emitted by the electron accelerator of the SAPHIR facility owned by CEA LIST. Energy spectra, angular distribution and intensity of the photoneutron flux have been obtained. A photoneutron interrogation measurement cell based on this accelerator has been built and assessed by carrying out measurements on uranium samples. Delayed gamma-ray spectra have been acquired and enabled to confirm the experimental feasibility of our method. (authors)

  11. Numerical studies on the electro-optic detection of femtosecond electron bunches

    Directory of Open Access Journals (Sweden)

    S. Casalbuoni

    2008-07-01

    Full Text Available The electro-optic (EO effect is a powerful diagnostic tool for determining the time profile of ultrashort relativistic electron bunches. When a relativistic bunch passes within a few mm of an electro-optic crystal, its transient electric field is equivalent to a half-cycle THz pulse passing through the crystal. The induced birefringence can be detected with polarized femtosecond laser pulses. A simulation code has been written in order to understand the faithfulness and the limitations of electron bunch shape reconstruction by EO sampling. The THz pulse and the laser pulse are propagated as wave packets through the EO crystal. Alternatively, the response function method is applied. Using experimental data on the material properties of zinc telluride (ZnTe and gallium phosphide (GaP, the effects of velocity mismatch, pulse shape distortion, and signal broadening are explicitly taken into account. The simulations show that the most severe limitation on the time resolution is given by the transverse-optical (TO lattice oscillation in the EO crystal. The lowest TO frequency is 5.3 THz in ZnTe and 11 THz in GaP. Only the Fourier components below the TO resonance are usable for the bunch shape reconstruction. This implies that the shortest rms bunch length which can be resolved with moderate distortion amounts to σ≈90  fs in ZnTe and σ≈50  fs in GaP. The influence of the crystal thickness on the amplitude and width of the EO signal is studied. The optimum thickness is in the range from 100 to 300  μm for ZnTe and from 50 to 100  μm for GaP.

  12. Molecular gated-AlGaN/GaN high electron mobility transistor for pH detection.

    Science.gov (United States)

    Ding, Xiangzhen; Yang, Shuai; Miao, Bin; Gu, Le; Gu, Zhiqi; Zhang, Jian; Wu, Baojun; Wang, Hong; Wu, Dongmin; Li, Jiadong

    2018-04-18

    A molecular gated-AlGaN/GaN high electron mobility transistor has been developed for pH detection. The sensing surface of the sensor was modified with 3-aminopropyltriethoxysilane to provide amphoteric amine groups, which would play the role of receptors for pH detection. On modification with 3-aminopropyltriethoxysilane, the transistor exhibits good chemical stability in hydrochloric acid solution and is sensitive for pH detection. Thus, our molecular gated-AlGaN/GaN high electron mobility transistor acheived good electrical performances such as chemical stability (remained stable in hydrochloric acid solution), good sensitivity (37.17 μA/pH) and low hysteresis. The results indicate a promising future for high-quality sensors for pH detection.

  13. Acquisition of electrical signals using commercial electronic components for detection system of Lead ion in distilled water

    Science.gov (United States)

    Pujiyanto; Yasin, M.; Rusydi, F.

    2018-03-01

    Development of lead ion detection systems is expected to have an advantage in terms of simplicity of the device and easy for concentration analysis of a lead ion with very high performance. One important part of lead ion detection systems are electrical signal acquisition parts. The electrical signal acquisition part uses the main electronic components: non inverting op-amplifier, instrumentation amplifier, multiplier circuit and logarithmic amplifier. Here will be shown the performance of lead ion detection systems when the existing electrical signal processors use commercial electronic components. The results that can be drawn from this experimental were the lead ion sensor that has been developed can be used to detect lead ions with a sensitivity of 10.48 mV/ppm with the linearity 97.11% and had a measurement range of 0.1 ppm to 80 ppm.

  14. Design of a single-step immunoassay principle based on the combination of an enzyme-labeled antibody release coating and a hydrogel copolymerized with a fluorescent enzyme substrate in a microfluidic capillary device.

    Science.gov (United States)

    Wakayama, Hideki; Henares, Terence G; Jigawa, Kaede; Funano, Shun-ichi; Sueyoshi, Kenji; Endo, Tatsuro; Hisamoto, Hideaki

    2013-11-21

    A combination of an enzyme-labeled antibody release coating and a novel fluorescent enzyme substrate-copolymerized hydrogel in a microchannel for a single-step, no-wash microfluidic immunoassay is demonstrated. This hydrogel discriminates the free enzyme-conjugated antibody from an antigen-enzyme-conjugated antibody immunocomplex based on the difference in molecular size. A selective and sensitive immunoassay, with 10-1000 ng mL(-1) linear range, is reported.

  15. An evaluation of a single-step extraction chromatography separation method for Sm-Nd isotope analysis of micro-samples of silicate rocks by high-sensitivity thermal ionization mass spectrometry

    International Nuclear Information System (INIS)

    Li Chaofeng; Li Xianhua; Li Qiuli; Guo Jinghui; Li Xianghui; Liu Tao

    2011-01-01

    Graphical abstract: Distribution curve of all eluting fractions for a BCR-2 (1-2-3.5-7 mg) on LN column using HCl and HF as eluting reagent. Highlights: → This analytical protocol affords a simple and rapid analysis for Sm and Nd isotope in minor rock samples. → The single-step separation method exhibits satisfactory separation effect for complex silicate samples. → Corrected 143 Nd/ 144 Nd data show excellent accuracy even if the 140 Ce 16 O + / 144 Nd 16 O + ratio reached to 0.03. - Abstract: A single-step separation scheme is presented for Sm-Nd radiogenic isotope system on very small samples (1-3 mg) of silicate rock. This method is based on Eichrom LN Spec chromatographic material and affords a straightforward separation of Sm-Nd from complex matrix with good purity and satisfactory blank levels, suitable for thermal ionization mass spectrometry (TIMS). This technique, characterized by high efficiency (single-step Sm-Nd separation) and high sensitivity (TIMS on NdO + ion beam), is able to process rapidly (3-4 h), with low procedure blanks ( 143 Nd/ 144 Nd ratios and Sm-Nd concentrations are presented for eleven international silicate rock reference materials, spanning a wide range of Sm-Nd contents and bulk compositions. The analytical results show a good agreement with recommended values within ±0.004% for the 143 Nd/ 144 Nd isotopic ratio and ±2% for Sm-Nd quantification at the 95% confidence level. It is noted that the uncertainty of this method is about 3 times larger than typical precision achievable with two-stage full separation followed by state-of-the-art conventional TIMS using Nd + ion beams which require much larger amounts of Nd. Hence, our single-step separation followed by NdO + ion beam technique is preferred to the analysis for microsamples.

  16. Femtosecond stimulated Raman spectroscopy as a tool to detect molecular vibrations in ground and excited electronic states

    Energy Technology Data Exchange (ETDEWEB)

    Gelin, Maxim F.; Domcke, Wolfgang [Department of Chemistry, Technische Universität München, D-85747 Garching (Germany); Rao, B. Jayachander [Departamento de Química and Centro de Química, Universidade de Coimbra, 3004-535 Coimbra (Portugal)

    2016-05-14

    We give a detailed theoretical analysis of the simplest variant of femtosecond stimulated Raman spectroscopy, where a picosecond Raman pump pulse and a femtosecond Raman probe pulse are applied resonantly to a chromophore in thermal equilibrium in the ground electronic state. We demonstrate that this technique is capable of the detection of dephasing-free Raman-like lines revealing vibrational modes not only in the electronic ground state but also in the excited electronic state of the chromophore. The analytical results obtained with simplifying assumptions for the shape of the laser pulses are substantiated by numerical simulations with realistic laser pulses, employing the equation-of-motion phase-matching approach.

  17. Single-step simultaneous side-by-side placement of a self-expandable metallic stent with a 6-Fr delivery system for unresectable malignant hilar biliary obstruction: a feasibility study.

    Science.gov (United States)

    Kawakubo, Kazumichi; Kawakami, Hiroshi; Kuwatani, Masaki; Kudo, Taiki; Abe, Yoko; Kawahata, Shuhei; Kubo, Kimitoshi; Kubota, Yoshimasa; Sakamoto, Naoya

    2015-02-01

    Bilateral self-expandable metallic stent (SEMS) placement for the management of unresectable malignant hilar biliary obstruction (UMHBO) is technically challenging to perform using the existing metallic stents with thick delivery systems. The recently developed 6-Fr delivery systems could facilitate a single-step simultaneous side-by-side placement through the accessory channel of the duodenoscope. The aim of this study was to evaluate the feasibility of this procedure. Between May and September 2013, 13 consecutive patients with UMHBO underwent a single-step simultaneous side-by-side placement of SEMS with the 6-Fr delivery system. The technical success rate, stent patency, and rate of complications were evaluated from the prospectively collected database. Technical success was achieved in 11 (84.6%, 95% confidence interval [CI]: 57.8-95.8) patients. The median procedure time was 25 min. Early and late complications were observed in 23% (one segmental cholangitis and two liver abscesses) and 15% (one segmental cholangitis and one cholecystitis) patients, respectively. Median dysfunction free patency was 263 days (95% CI: 37-263). Five patients (38%) experienced stent occlusion that was successfully managed by endoscopic stent placement. A single-step simultaneous side-by-side placement of SEMS with a 6-Fr delivery system was feasible for the management of UMHBO. © 2014 Japanese Society of Hepato-Biliary-Pancreatic Surgery.

  18. Detection of reactive oxygen species in isolated, perfused lungs by electron spin resonance spectroscopy

    Directory of Open Access Journals (Sweden)

    Schudt Christian

    2005-07-01

    Full Text Available Abstract Background The sources and measurement of reactive oxygen species (ROS in intact organs are largely unresolved. This may be related to methodological problems associated with the techniques currently employed for ROS detection. Electron spin resonance (ESR with spin trapping is a specific method for ROS detection, and may address some these technical problems. Methods We have established a protocol for the measurement of intravascular ROS release from isolated buffer-perfused and ventilated rabbit and mouse lungs, combining lung perfusion with the spin probe l-hydroxy-3-carboxy-2,2,5,5-tetramethylpyrrolidine (CPH and ESR spectroscopy. We then employed this technique to characterize hypoxia-dependent ROS release, with specific attention paid to NADPH oxidase-dependent superoxide formation as a possible vasoconstrictor pathway. Results While perfusing lungs with CPH over a range of inspired oxygen concentrations (1–21 %, the rate of CP• formation exhibited an oxygen-dependence, with a minimum at 2.5 % O2. Addition of superoxide dismutase (SOD to the buffer fluid illustrated that a minor proportion of this intravascular ROS leak was attributable to superoxide. Stimulation of the lungs by injection of phorbol-12-myristate-13-acetate (PMA into the pulmonary artery caused a rapid increase in CP• formation, concomitant with pulmonary vasoconstriction. Both the PMA-induced CPH oxidation and the vasoconstrictor response were largely suppressed by SOD. When the PMA challenge was performed at different oxygen concentrations, maximum superoxide liberation and pulmonary vasoconstriction occurred at 5 % O2. Using a NADPH oxidase inhibitor and NADPH-oxidase deficient mice, we illustrated that the PMA-induced superoxide release was attributable to the stimulation of NADPH oxidases. Conclusion The perfusion of isolated lungs with CPH is suitable for detection of intravascular ROS release by ESR spectroscopy. We employed this technique to

  19. Determination of sulfur dioxide in wine using headspace gas chromatography and electron capture detection.

    Science.gov (United States)

    Aberl, A; Coelhan, M

    2013-01-01

    Sulfites are routinely added as preservatives and antioxidants in wine production. By law, the total sulfur dioxide content in wine is restricted and therefore must be monitored. Currently, the method of choice for determining the total content of sulfur dioxide in wine is the optimised Monier-Williams method, which is time consuming and laborious. The headspace gas chromatographic method described in this study offers a fast and reliable alternative method for the detection and quantification of the sulfur dioxide content in wine. The analysis was performed using an automatic headspace injection sampler, coupled with a gas chromatograph and an electron capture detector. The method is based on the formation of gaseous sulfur dioxide subsequent to acidification and heating of the sample. In addition to free sulfur dioxide, reversibly bound sulfur dioxide in carbonyl compounds, such as acetaldehyde, was also measured with this method. A total of 20 wine samples produced using diverse grape varieties and vintages of varied provenance were analysed using the new method. For reference and comparison purposes, 10 of the results obtained by the proposed method were compared with those acquired by the optimised Monier-Williams method. Overall, the results from the headspace analysis showed good correlation (R = 0.9985) when compared with the conventional method. This new method requires minimal sample preparation and is simple to perform, and the analysis can also be completed within a short period of time.

  20. Gas chromatographic determination with electron capture detection of residual ethylene oxide in intraocular lenses

    Energy Technology Data Exchange (ETDEWEB)

    Kikuchi, H.; Nakamura, A.; Tsuji, K.

    1988-01-01

    A sensitive method is described to determine trace quantities of ethylene oxide (EO) in EO-sterilized intraocular lenses (IOLs). An IOL is dipped in ethanol containing 0.25 ppm propylene oxide (PO) in a 4 mL vial, 2 drops of freshly distilled hydrobromic acid is added through a septum, and the mixture is warmed at 50/sup 0/C for 24 h. It is then neutralized by vigorous shaking with sodium bicarbonate, dehydrated with anhydrous sodium sulfate, and filtered. The filtrate is injected into a gas chromatograph with electron-capture detection, and the peak height ratio of ethylene bromohydrin/propylene bromohydrin is measured. EO residue is calculated from the calibration curve obtained through a similar procedure with the standard EO/PO solutions. The limit of determination is 0.04 ..mu..g/lens (ca 2.0 ppm). When EO residue levels were determined for IOLs sampled at 3 different aeration periods after stabilization, the authors found that 9 days of aeration was necessary to meet the US Food and Drug Administration proposed limit for EO residue in IOLs.

  1. Terahertz imaging and spectroscopy based on hot electron bolometer (HEB) heterodyne detection

    Science.gov (United States)

    Gerecht, Eyal; You, Lixing

    2008-02-01

    Imaging and spectroscopy at terahertz frequencies have great potential for healthcare, plasma diagnostics, and homeland security applications. Terahertz frequencies correspond to energy level transitions of important molecules in biology and astrophysics. Terahertz radiation (T-rays) can penetrate clothing and, to some extent, can also penetrate biological materials. Because of their shorter wavelengths, they offer higher spatial resolution than do microwaves or millimeter waves. We are developing hot electron bolometer (HEB) mixer receivers for heterodyne detection at terahertz frequencies. HEB detectors provide unprecedented sensitivity and spectral resolution at terahertz frequencies. We describe the development of a two-pixel focal plane array (FPA) based on HEB technology. Furthermore, we have demonstrated a fully automated, two-dimensional scanning, passive imaging system based on our HEB technology operating at 0.85 THz. Our high spectral resolution terahertz imager has a total system noise equivalent temperature difference (NEΔT) value of better than 0.5 K and a spatial resolution of a few millimeters. HEB technology is becoming the basis for advanced terahertz imaging and spectroscopic technologies for the study of biological and chemical agents over the entire terahertz spectrum.

  2. Optically detected electron spin-flip resonance in CdMnTe

    International Nuclear Information System (INIS)

    Zeng, S.; Smith, L.C.; Davies, J.J.; Wolverson, D.; Bingham, S.J.; Aliev, G.N.

    2006-01-01

    We show that the spin-flip of electrons at neutral donors in a dilute magnetic semiconductor can be observed directly by means of optically-detected magnetic resonance (ODMR). Spectra obtained at 105 GHz for a bulk crystal of Cd 1-x Mn x Te with x = 0.005 showed strong signals with g -values ranging between 12 (at 4.2 K) and 35 (at 1.7 K), with magnetic resonance linewidths ranging from 0.3 Tesla to 0.1 Tesla at the lowest temperature. In energy terms, these linewidths are independent of temperature and agree with those in spin-flip Raman spectra from the same specimen. The line broadening is caused by fluctuations in the number of manganese ions that interact with a particular donor and an analysis of this leads to a value for the donor Bohr radius of 4.5 nm. (copyright 2006 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  3. Direct detection of a break in the teraelectronvolt cosmic-ray spectrum of electrons and positrons

    Science.gov (United States)

    DAMPE Collaboration; Ambrosi, G.; An, Q.; Asfandiyarov, R.; Azzarello, P.; Bernardini, P.; Bertucci, B.; Cai, M. S.; Chang, J.; Chen, D. Y.; Chen, H. F.; Chen, J. L.; Chen, W.; Cui, M. Y.; Cui, T. S.; D'Amone, A.; de Benedittis, A.; De Mitri, I.; di Santo, M.; Dong, J. N.; Dong, T. K.; Dong, Y. F.; Dong, Z. X.; Donvito, G.; Droz, D.; Duan, K. K.; Duan, J. L.; Duranti, M.; D'Urso, D.; Fan, R. R.; Fan, Y. Z.; Fang, F.; Feng, C. Q.; Feng, L.; Fusco, P.; Gallo, V.; Gan, F. J.; Gao, M.; Gao, S. S.; Gargano, F.; Garrappa, S.; Gong, K.; Gong, Y. Z.; Guo, D. Y.; Guo, J. H.; Hu, Y. M.; Huang, G. S.; Huang, Y. Y.; Ionica, M.; Jiang, D.; Jiang, W.; Jin, X.; Kong, J.; Lei, S. J.; Li, S.; Li, X.; Li, W. L.; Li, Y.; Liang, Y. F.; Liang, Y. M.; Liao, N. H.; Liu, H.; Liu, J.; Liu, S. B.; Liu, W. Q.; Liu, Y.; Loparco, F.; Ma, M.; Ma, P. X.; Ma, S. Y.; Ma, T.; Ma, X. Q.; Ma, X. Y.; Marsella, G.; Mazziotta, M. N.; Mo, D.; Niu, X. Y.; Peng, X. Y.; Peng, W. X.; Qiao, R.; Rao, J. N.; Salinas, M. M.; Shang, G. Z.; H. Shen, W.; Shen, Z. Q.; Shen, Z. T.; Song, J. X.; Su, H.; Su, M.; Sun, Z. Y.; Surdo, A.; Teng, X. J.; Tian, X. B.; Tykhonov, A.; Vagelli, V.; Vitillo, S.; Wang, C.; Wang, H.; Wang, H. Y.; Wang, J. Z.; Wang, L. G.; Wang, Q.; Wang, S.; Wang, X. H.; Wang, X. L.; Wang, Y. F.; Wang, Y. P.; Wang, Y. Z.; Wen, S. C.; Wang, Z. M.; Wei, D. M.; Wei, J. J.; Wei, Y. F.; Wu, D.; Wu, J.; Wu, L. B.; Wu, S. S.; Wu, X.; Xi, K.; Xia, Z. Q.; Xin, Y. L.; Xu, H. T.; Xu, Z. L.; Xu, Z. Z.; Xue, G. F.; Yang, H. B.; Yang, P.; Yang, Y. Q.; Yang, Z. L.; Yao, H. J.; Yu, Y. H.; Yuan, Q.; Yue, C.; Zang, J. J.; Zhang, C.; Zhang, D. L.; Zhang, F.; Zhang, J. B.; Zhang, J. Y.; Zhang, J. Z.; Zhang, L.; Zhang, P. F.; Zhang, S. X.; Zhang, W. Z.; Zhang, Y.; Zhang, Y. J.; Zhang, Y. Q.; Zhang, Y. L.; Zhang, Y. P.; Zhang, Z.; Zhang, Z. Y.; Zhao, H.; Zhao, H. Y.; Zhao, X. F.; Zhou, C. Y.; Zhou, Y.; Zhu, X.; Zhu, Y.; Zimmer, S.

    2017-12-01

    High-energy cosmic-ray electrons and positrons (CREs), which lose energy quickly during their propagation, provide a probe of Galactic high-energy processes and may enable the observation of phenomena such as dark-matter particle annihilation or decay. The CRE spectrum has been measured directly up to approximately 2 teraelectronvolts in previous balloon- or space-borne experiments, and indirectly up to approximately 5 teraelectronvolts using ground-based Cherenkov γ-ray telescope arrays. Evidence for a spectral break in the teraelectronvolt energy range has been provided by indirect measurements, although the results were qualified by sizeable systematic uncertainties. Here we report a direct measurement of CREs in the energy range 25 gigaelectronvolts to 4.6 teraelectronvolts by the Dark Matter Particle Explorer (DAMPE) with unprecedentedly high energy resolution and low background. The largest part of the spectrum can be well fitted by a ‘smoothly broken power-law’ model rather than a single power-law model. The direct detection of a spectral break at about 0.9 teraelectronvolts confirms the evidence found by previous indirect measurements, clarifies the behaviour of the CRE spectrum at energies above 1 teraelectronvolt and sheds light on the physical origin of the sub-teraelectronvolt CREs.

  4. MATLAB Algorithms for Rapid Detection and Embedding of Palindrome and Emordnilap Electronic Watermarks in Simulated Chemical and Biological Image Data

    National Research Council Canada - National Science Library

    Robbins, Ronny C

    2004-01-01

    .... This is similar to words such as STOP which when flipped left right gives the new word POTS. Emordnilap is palindrome spelled backwards. This paper explores the use of MATLAB algorithms in the rapid detection and embedding of palindrome and emordnilap electronic watermarks in simulated chemical and biological Image Data.

  5. Advances in Electronic-Nose Technologies for the Detection of Volatile Biomarker Metabolites in the Human Breath

    Directory of Open Access Journals (Sweden)

    Alphus D. Wilson

    2015-03-01

    Full Text Available Recent advancements in the use of electronic-nose (e-nose devices to analyze human breath profiles for the presence of specific volatile metabolites, known as biomarkers or chemical bio-indicators of specific human diseases, metabolic disorders and the overall health status of individuals, are providing the potential for new noninvasive tools and techniques useful to point-of-care clinical disease diagnoses. This exciting new area of electronic disease detection and diagnosis promises to yield much faster and earlier detection of human diseases and disorders, allowing earlier, more effective treatments, resulting in more rapid patient recovery from various afflictions. E-nose devices are particularly suited for the field of disease diagnostics, because they are sensitive to a wide range of volatile organic compounds (VOCs and can effectively distinguish between different complex gaseous mixtures via analysis of electronic aroma sensor-array output profiles of volatile metabolites present in the human breath. This review provides a summary of some recent developments of electronic-nose technologies, particularly involving breath analysis, with the potential for providing many new diagnostic applications for the detection of specific human diseases associated with different organs in the body, detectable from e-nose analyses of aberrant disease-associated VOCs present in air expired from the lungs.

  6. Single step synthesis of gold-amino acid composite, with the evidence of the catalytic hydrogen atom transfer (HAT) reaction, for the electrochemical recognition of Serotonin

    Science.gov (United States)

    Choudhary, Meenakshi; Siwal, Samarjeet; Nandi, Debkumar; Mallick, Kaushik

    2016-03-01

    A composite architecture of amino acid and gold nanoparticles has been synthesized using a generic route of 'in-situ polymerization and composite formation (IPCF)' [1,2]. The formation mechanism of the composite has been supported by a model hydrogen atom (H•≡H++e-) transfer (HAT) type of reaction which belongs to the proton coupled electron transfer (PCET) mechanism. The 'gold-amino acid composite' was used as a catalyst for the electrochemical recognition of Serotonin.

  7. Specific, sensitive, high-resolution detection of protein molecules in eukaryotic cells using metal-tagging transmission electron microscopy

    Science.gov (United States)

    Risco, Cristina; Sanmartín-Conesa, Eva; Tzeng, Wen-Pin; Frey, Teryl K.; Seybold, Volker; de Groot, Raoul J.

    2012-01-01

    Summary More than any other methodology, transmission electron microscopy (TEM) has contributed to our understanding of the architecture and organization of cells. With current detection limits approaching atomic resolution, it will ultimately become possible to ultrastructurally image intracellular macromolecular assemblies in situ. Presently, however, methods to unambiguously identify proteins within the crowded environment of the cell’s interior are lagging behind. We describe a novel approach, metal-tagging TEM (METTEM) that allows detection of intracellular proteins in mammalian cells with high specificity, exceptional sensitivity and at molecular scale resolution. In live cells treated with gold salts, proteins bearing a small metal-binding tag will form 1-nm gold nanoclusters, readily detectable in electron micrographs. The applicability and strength of METTEM is demonstrated by a study of Rubella virus replicase and capsid proteins, which revealed virus-induced cell structures not seen before. PMID:22579245

  8. Estimating trematode prevalence in snail hosts using a single-step duplex PCR: how badly does cercarial shedding underestimate infection rates?

    Czech Academy of Sciences Publication Activity Database

    Born-Torrijos, A.; Poulin, R.; Raga, J. A.; Holzer, Astrid S.

    2014-01-01

    Roč. 7, MAY 2014 (2014), s. 243 ISSN 1756-3305 R&D Projects: GA ČR GBP505/12/G112 Institutional support: RVO:60077344 Keywords : prevalence * detection * snail host * double infection * single-steo duplex PCR Subject RIV: EB - Genetics ; Molecular Biology Impact factor: 3.430, year: 2014

  9. Detection of coronary calcium with electron beam tomography in coronary artery disease

    International Nuclear Information System (INIS)

    Haberl, R.; Knez, A.; Becker, A.; Becker, C.; Bruening, R.; Reiser, M.; Maass, A.; Steinbeck, G.

    1998-01-01

    Purpose: Coronary calcium is a powerful indicator of arteriosclerosis and can be detected very precisely with electron beam tomography. The method can be applied in patients with known coronary artery disease or in asymptomatic patients at risk of arteriosclerotic disease. Results: At the University of Munich we performed an EBT scan of the heart in 1100 patients within the last year. In 567 patients coronary angiography was performed also (±3 days). Confirming previous reports in the literature, we found a correlation of the calcium score with the age and gender of the patients. Severe coronary artery disease (stenoses ≥ 75%) was associated with significantly more calcium than less severe CAD. The calcium score did not discriminate between one-, two- and three-vessel disease. The site of calcification does not correlate with the localization of stenoses. Thirty-three percent of the patients with significant coronary artery disease showed a normal age-adjusted calcium score; a total of 8.1% of patients with severe stenoses did not reveal any coronary calcification (score =0). With asymptomatic patients there are only a few studies available. Soft plaques cannot be detected with EBT, but in most patients soft plaques occur together with hard plaques. Our results show that spiral CT of the newest generation may also be used for calcium screening. There was an excellent correlation of the calcium scores of EBT and spiral CT at all levels of calcification. Discussion: Coronary calcium is a sensitive marker of coronary artery disease. In the clinical setting EBT is indicated in patients with known coronary artery disease (to evaluate prognosis), in patients who are unable to perform a stress test, and in patients with atypical chest pain. However, lack of calcification may be associated with severe stenoses in a minority of patients. The clinical value in asymptomatic patients needs to be defined: Randomized studies are necessary. We see a possible indication in

  10. Electron spin resonance for the detection of long-range spin nematic order

    Science.gov (United States)

    Furuya, Shunsuke C.; Momoi, Tsutomu

    2018-03-01

    Spin nematic phase is a quantum magnetic phase characterized by a quadrupolar order parameter. Since the quadrupole operators are directly coupled to neither the magnetic field nor the neutron, currently, it is an important issue to develop a method for detecting the long-range spin nematic order. In this paper, we propose that electron spin resonance (ESR) measurements enable us to detect the long-range spin nematic order. We show that the frequency of the paramagnetic resonance peak in the ESR spectrum is shifted by the ferroquadrupolar order parameter together with other quantities. The ferroquadrupolar order parameter is extractable from the angular dependence of the frequency shift. In contrast, the antiferroquadrupolar order parameter is usually invisible in the frequency shift. Instead, the long-range antiferroquadrupolar order yields a characteristic resonance peak in the ESR spectrum, which we call a magnon-pair resonance peak. This resonance corresponds to the excitation of the bound magnon pair at the wave vector k =0 . Reflecting the condensation of bound magnon pairs, the field dependence of the magnon-pair resonance frequency shows a singular upturn at the saturation field. Moreover, the intensity of the magnon-pair resonance peak shows a characteristic angular dependence and it vanishes when the magnetic field is parallel to one of the axes that diagonalize the weak anisotropic interactions. We confirm these general properties of the magnon-pair resonance peak in the spin nematic phase by studying an S =1 bilinear-biquadratic model on the square lattice in the linear flavor-wave approximation. In addition, we argue applications to the S =1/2 frustrated ferromagnets and also the S =1/2 orthogonal dimer spin system SrCu2(BO3)2, both of which are candidate materials of spin nematics. Our theory for the antiferroquadrupolar ordered phase is consistent with many features of the magnon-pair resonance peak experimentally observed in the low

  11. Detection of 5-hydroxymethylfurfural and furfural in the aerosol of electronic cigarettes.

    Science.gov (United States)

    Soussy, Sarah; El-Hellani, Ahmad; Baalbaki, Rima; Salman, Rola; Shihadeh, Alan; Saliba, Najat A

    2016-11-01

    The wide availability of sweet flavours has been hypothesised as a factor in the popularity of electronic cigarette (ECIG), especially among youth. Saccharides, which are commonly used to impart a sweet flavour to ECIG liquids, thermally degrade to produce toxic compounds, like aldehydes and furans. This study investigates the formation of furanic compounds in aerosols when ECIG liquid solutions of varying sweetener concentrations are vaped under different power and puff duration. Liquids are prepared by mixing aqueous sucrose, glucose or sorbitol solutions to a 70/30 propylene glycol/glycerin solution. Aerosols are generated and trapped on filter pads using a commercially available ECIG operating at 4.3 and 10.8 W and 4 and 8 s puff duration. Extraction, elimination of matrix interference and quantification are achieved using novel solid phase extraction and gas chromatography tandem mass spectrometry methods (GC-MS). Well-resolved GC peaks of 5-hydroxymethylfurfural (HMF) and furfural (FA) are detected. Both HMF and FA are quantified in the aerosols of sweet-flavoured e-liquids under various vaping conditions. Levels of furan emissions are significantly correlated with electric power and sweetener concentration and not with puff duration. Unlike saccharides, the formation of HMF and FA from a sugar alcohol is negligible. The addition of sweeteners to ECIG liquids exposes ECIG user to furans, a toxic class of compounds. Under certain conditions, the per-puff yield of HMF and FA in ECIG emissions is comparable to values reported for combustible cigarettes. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  12. Ponderomotive Generation and Detection of Attosecond Free-Electron Pulse Trains

    Science.gov (United States)

    Kozák, M.; Schönenberger, N.; Hommelhoff, P.

    2018-03-01

    Atomic motion dynamics during structural changes or chemical reactions have been visualized by pico- and femtosecond pulsed electron beams via ultrafast electron diffraction and microscopy. Imaging the even faster dynamics of electrons in atoms, molecules, and solids requires electron pulses with subfemtosecond durations. We demonstrate here the all-optical generation of trains of attosecond free-electron pulses. The concept is based on the periodic energy modulation of a pulsed electron beam via an inelastic interaction, with the ponderomotive potential of an optical traveling wave generated by two femtosecond laser pulses at different frequencies in vacuum. The subsequent dispersive propagation leads to a compression of the electrons and the formation of ultrashort pulses. The longitudinal phase space evolution of the electrons after compression is mapped by a second phase-locked interaction. The comparison of measured and calculated spectrograms reveals the attosecond temporal structure of the compressed electron pulse trains with individual pulse durations of less than 300 as. This technique can be utilized for tailoring and initial characterization of suboptical-cycle free-electron pulses at high repetition rates for stroboscopic time-resolved experiments with subfemtosecond time resolution.

  13. A rule-based electronic phenotyping algorithm for detecting clinically relevant cardiovascular disease cases.

    Science.gov (United States)

    Esteban, Santiago; Rodríguez Tablado, Manuel; Ricci, Ricardo Ignacio; Terrasa, Sergio; Kopitowski, Karin

    2017-07-14

    The implementation of electronic medical records (EMR) is becoming increasingly common. Error and data loss reduction, patient-care efficiency increase, decision-making assistance and facilitation of event surveillance, are some of the many processes that EMRs help improve. In addition, they show a lot of promise in terms of data collection to facilitate observational epidemiological studies and their use for this purpose has increased significantly over the recent years. Even though the quantity and availability of the data are clearly improved thanks to EMRs, still, the problem of the quality of the data remains. This is especially important when attempting to determine if an event has actually occurred or not. We sought to assess the sensitivity, specificity, and agreement level of a codes-based algorithm for the detection of clinically relevant cardiovascular (CaVD) and cerebrovascular (CeVD) disease cases, using data from EMRs. Three family physicians from the research group selected clinically relevant CaVD and CeVD terms from the international classification of primary care, Second Edition (ICPC-2), the ICD 10 version 2015 and SNOMED-CT 2015 Edition. These terms included both signs, symptoms, diagnoses and procedures associated with CaVD and CeVD. Terms not related to symptoms, signs, diagnoses or procedures of CaVD or CeVD and also those describing incidental findings without clinical relevance were excluded. The algorithm yielded a positive result if the patient had at least one of the selected terms in their medical records, as long as it was not recorded as an error. Else, if no terms were found, the patient was classified as negative. This algorithm was applied to a randomly selected sample of the active patients within the hospital's HMO by 1/1/2005 that were 40-79 years old, had at least one year of seniority in the HMO and at least one clinical encounter. Thus, patients were classified into four groups: (1) Negative patients (2) Patients with Ca

  14. Electronics

    Science.gov (United States)

    2001-01-01

    International Acer Incorporated, Hsin Chu, Taiwan Aerospace Industrial Development Corporation, Taichung, Taiwan American Institute of Taiwan, Taipei, Taiwan...Singapore and Malaysia .5 - 4 - The largest market for semiconductor products is the high technology consumer electronics industry that consumes up...Singapore, and Malaysia . A new semiconductor facility costs around $3 billion to build and takes about two years to become operational

  15. Calibration of a silicon semiconductor detecter using a 2 MeV electron accelerator beam

    International Nuclear Information System (INIS)

    Fleurot, N.; Gouard, P.; Mazataud, E.; Nail, M.; Savy, C.; Bayer, C.; Cauchois, Y.; Kherouf, R.; Mathieu, D.

    1981-01-01

    This paper describes the current mode calibration, carried out on a 2 MeV electron accelerator, of PIN detectors involved in electron spectrum measurements for laser-matter interaction experiments. A theoretical analysis simulating the interaction between the incident electrons and the irradiated medium has been carried out using the FOTELEC code. It accounts well for the experimental results giving a reasonable value for the mean electron-hole pair formation energy when back-scattering corrections are included. This work provides the transfer function data required for a plasma diagnostic spectrometer. (orig.)

  16. Very low-energy conversion electron detection (VLECED) system at the isocele on-line isotope separator, Orsay

    International Nuclear Information System (INIS)

    Kilcher, P.; Sauvage, J.; Munsch, J.; Obert, J.; Caruette, A.; Ferro, A.; Boissier, G.; Fournet-Fayas, J.; Ducourtieux, M.; Landois, G.

    1988-01-01

    A system designed and installed at the on-line isotope separator ISOCELE II allows the high resolution detection of low-energy conversion electrons (down to 1 keV) emitted by mass separated radioactive sources: the use of a special tape transport permits both the slowing down of the incoming beam of radioactive ions up to a collection point and the acceleration of the electrons emitted by the collected sources brought to a flat magnetic spectrograph. Typical spectra so obtained are presented

  17. Enhanced plasma wave detection of terahertz radiation using multiple high electron-mobility transistors connected in series

    KAUST Repository

    Elkhatib, Tamer A.; Kachorovskiǐ, Valentin Yu; Stillman, William J.; Veksler, Dmitry B.; Salama, Khaled N.; Zhang, Xicheng; Shur, Michael S.

    2010-01-01

    We report on enhanced room-temperature detection of terahertz radiation by several connected field-effect transistors. For this enhanced nonresonant detection, we have designed, fabricated, and tested plasmonic structures consisting of multiple InGaAs/GaAs pseudomorphic high electron-mobility transistors connected in series. Results show a 1.63-THz response that is directly proportional to the number of detecting transistors biased by a direct drain current at the same gate-to-source bias voltages. The responsivity in the saturation regime was found to be 170 V/W with the noise equivalent power in the range of 10-7 W/Hz0.5. The experimental data are in agreement with the detection mechanism based on the rectification of overdamped plasma waves excited by terahertz radiation in the transistor channel. © 2010 IEEE.

  18. The detection of hard x-rays (10-140 KeV) by channel plate electron multipliers

    International Nuclear Information System (INIS)

    Bateman, J.E.

    1976-12-01

    Results are presented indicating that hard X-rays in the energy range 10 to 50 keV can be detected with good efficiency (5 to 10%) in channel plate electron multipliers (CPEM). From 50 keV to 140 keV the detection efficiency lies in the range 1 to 2%. A simple physical model is developed which indicates that not only can good detection efficiency be obtained but that very good X-ray imaging is possible. The model predicts that with further development, a wideband, hard X-ray detector can be realised with a detection efficiency in the range 5 to 20% and spatial response better than 10 lp/mm in the energy range 10 to 140 keV. (author)

  19. Ultrasensitive detection of Hg2+ using oligonucleotide-functionalized AlGaN/GaN high electron mobility transistor

    International Nuclear Information System (INIS)

    Cheng, Junjie; Li, Jiadong; Miao, Bin; Wu, Dongmin; Wang, Jine; Pei, Renjun; Wu, Zhengyan

    2014-01-01

    An oligonucleotide-functionalized ion sensitive AlGaN/GaN high electron mobility transistor (HEMT) was fabricated to detect trace amounts of Hg 2+ . The advantages of ion sensitive AlGaN/GaN HEMT and highly specific binding interaction between Hg 2+ and thymines were combined. The current response of this Hg 2+ ultrasensitive transistor was characterized. The current increased due to the accumulation of Hg 2+ ions on the surface by the highly specific thymine-Hg 2+ -thymine recognition. The dynamic linear range for Hg 2+ detection has been determined in the concentrations from 10 −14 to 10 −8 M and a detection limit below 10 −14 M level was estimated, which is the best result of AlGaN/GaN HEMT biosensors for Hg 2+ detection till now.

  20. Enhanced plasma wave detection of terahertz radiation using multiple high electron-mobility transistors connected in series

    KAUST Repository

    Elkhatib, Tamer A.

    2010-02-01

    We report on enhanced room-temperature detection of terahertz radiation by several connected field-effect transistors. For this enhanced nonresonant detection, we have designed, fabricated, and tested plasmonic structures consisting of multiple InGaAs/GaAs pseudomorphic high electron-mobility transistors connected in series. Results show a 1.63-THz response that is directly proportional to the number of detecting transistors biased by a direct drain current at the same gate-to-source bias voltages. The responsivity in the saturation regime was found to be 170 V/W with the noise equivalent power in the range of 10-7 W/Hz0.5. The experimental data are in agreement with the detection mechanism based on the rectification of overdamped plasma waves excited by terahertz radiation in the transistor channel. © 2010 IEEE.

  1. Development of x-y table for baby electron beam detection using dispose printer

    International Nuclear Information System (INIS)

    Leo Kwee Wah; Mohd Rizal Md Chulan; Muhamad Zahidee Taat; Abu Bakar Md Ghazali; Mohamad Nor Atan; Siti A'iasah Hashim

    2005-01-01

    This paper describes the development of X-Y table using the dispose printer. It consists the mechanical part and the control (Interfacing and software/programming) part description. As the result, the x-y table will be used to moves the electron beam detector for the baby electron beam machine. (Author)

  2. A neural network detection system for lower-hybrid cavities in electron plasma density measured by the FREJA satellite

    International Nuclear Information System (INIS)

    Waldemark, J.; Karlsson, Jan

    1995-03-01

    This paper presents a lower-hybrid cavity detection system, CDS, for measurements of electron plasma density on the FREJA satellite wave experiment. The system can reduce the amount of data to be analysed by as much as 96% and still retain more than 85% of the desired information. The CDS is a combination of a hybrid neural network, HNN and expert rules. The HNN is a Self Organizing Map, SOM, combined with a feed forward back propagation neural net, BP. The CDS can be controlled by the user to operate with various degrees of sensitivity. Maximum detection capability is as high as 95% with data reduction lowered to 85%. 10 refs

  3. A conductive polymer based electronic nose for early detection of Penicillium digitatum in post-harvest oranges

    International Nuclear Information System (INIS)

    Gruber, Jonas; Nascimento, Henry M.; Yamauchi, Elaine Y.; Li, Rosamaria W.C.; Esteves, Carlos H.A.; Rehder, Gustavo P.; Gaylarde, Christine C.; Shirakawa, Márcia A.

    2013-01-01

    We describe the construction of an electronic nose, comprising four chemiresistive sensors formed by the deposition of thin conductive polymer films onto interdigitated electrodes, attached to a personal computer via a data acquisition board. This e-nose was used to detect biodeterioration of oranges colonized by Penicillium digitatum. Significant responses were obtained after only 24 h of incubation i.e. at an early stage of biodeterioration, enabling remedial measures to be taken in storage facilities and efficiently distinguishing between good and poor quality fruits. The instrument has a very low analysis time of 40 s. - Highlights: • Early detection of Penicillium digitatum in oranges • Low cost electronic nose based on conductive polymers • Efficient distinction between good and poor quality fruits

  4. A conductive polymer based electronic nose for early detection of Penicillium digitatum in post-harvest oranges

    Energy Technology Data Exchange (ETDEWEB)

    Gruber, Jonas, E-mail: jogruber@iq.usp.br [Instituto de Química, Universidade de São Paulo, Av. Prof. Lineu Prestes, 748, CEP 05508-000 São Paulo, SP (Brazil); Nascimento, Henry M. [Sociedade Brasileira de Microbiologia, São Paulo, SP (Brazil); Yamauchi, Elaine Y. [Instituto de Química, Universidade de São Paulo, Av. Prof. Lineu Prestes, 748, CEP 05508-000 São Paulo, SP (Brazil); Li, Rosamaria W.C. [Centro Universitário Estácio Radial São Paulo, São Paulo, SP (Brazil); Esteves, Carlos H.A. [Instituto de Química, Universidade de São Paulo, Av. Prof. Lineu Prestes, 748, CEP 05508-000 São Paulo, SP (Brazil); Rehder, Gustavo P. [Escola Politécnica, Universidade de São Paulo, São Paulo, SP (Brazil); Gaylarde, Christine C. [University of Portsmouth, Portsmouth (United Kingdom); Shirakawa, Márcia A. [Escola Politécnica, Universidade de São Paulo, São Paulo, SP (Brazil)

    2013-07-01

    We describe the construction of an electronic nose, comprising four chemiresistive sensors formed by the deposition of thin conductive polymer films onto interdigitated electrodes, attached to a personal computer via a data acquisition board. This e-nose was used to detect biodeterioration of oranges colonized by Penicillium digitatum. Significant responses were obtained after only 24 h of incubation i.e. at an early stage of biodeterioration, enabling remedial measures to be taken in storage facilities and efficiently distinguishing between good and poor quality fruits. The instrument has a very low analysis time of 40 s. - Highlights: • Early detection of Penicillium digitatum in oranges • Low cost electronic nose based on conductive polymers • Efficient distinction between good and poor quality fruits.

  5. Enhanced Water Oxidation Photoactivity of Nano-Architectured α-Fe2O3-WO3 Composite Synthesized by Single-Step Hydrothermal Method

    Science.gov (United States)

    Rahman, Gul; Joo, Oh-Shim; Chae, Sang Youn; Shah, Anwar-ul-Haq Ali; Mian, Shabeer Ahmad

    2018-04-01

    This study reports the one-step in situ synthesis of a hematite-tungsten oxide (α-Fe2O3-WO3) composite on fluorine-doped tin oxide substrate via a simple hydrothermal method. Scanning electron microscopy images indicated that the addition of tungsten (W) precursor into the reaction mixture altered the surface morphology from nanorods to nanospindles. Energy-dispersive x-ray spectroscopy analysis confirmed the presence of W content in the composite. From the ultraviolet-visible spectrum of α-Fe2O3-WO3, it was observed that absorption began at ˜ 600 nm which corresponded to the bandgap energy of ˜ 2.01 eV. The α-Fe2O3-WO3 electrode demonstrated superior performance, with water oxidation photocurrent density of 0.80 mA/cm2 (at 1.6 V vs. reversible hydrogen electrode under standard illumination conditions; AM 1.5G, 100 mW/cm2) which is 2.4 times higher than α-Fe2O3 (0.34 mA/cm2). This enhanced water oxidation performance can be attributed to the better charge separation properties in addition to the large interfacial area of small-sized particles present in the α-Fe2O3-WO3 nanocomposite film.

  6. Dosimetric implications of shifts in linear accelerator electron beam energy detected in routine constancy checks: a scanning film densitometry detection method

    International Nuclear Information System (INIS)

    Cross, P.; Wang, Y.

    1993-01-01

    The effects of change in electron beam energy are primarily manifest by changes in the range parameters of the depth ionisation/dose curve. Even for a change of up to 10% in the mean energy at the surface, E O , the dose to the depth of maximum on the central axis changes by less than 1%. Using as a limit of acceptability that the change in the therapeutic range (R 85 ) should not be more than ±1.5 mm, the precision required by beam energy checking is that a change of 0.4 MeV in E O should be detectable for all electron beams provided by the accelerator. To satisfy this criterion a routine method is proposed that uses therapy verification film exposed to the electron beam under a perspex wedge. The automatically processed film is then scanned with the densitometer of a beam data acquisition system (BDAS). The optical density versus distance plot is analysed using the BDAS computer that converts it to a quasi-depth dose curve and then calculates E O and E p,0 from the range parameters. The results for electron beams from console energies of 5 to 14 MeV show that the test criterion is within the capability of the method, and that the method is very practical for routine use in a quality assurance program. 9 refs., 5 tab., 2 figs

  7. Fecal-tagging CT colonography with structure-analysis electronic cleansing for detection of colorectal flat lesions

    International Nuclear Information System (INIS)

    Xu, Yonghua; Cai, Wenli; Nappi, Janne; Yoshida, Hiro

    2012-01-01

    Purpose: To evaluate the feasibility and sensitivity of the 3D-reading of fecal-tagging CT colonography (CTC) with a novel structure-analysis electronic cleansing (SAEC) in detecting colorectal flat lesions in comparison with a cleansed 3D reading with Viatronix V3D Colon system (V3D) and primary uncleansed 2D reading (2D). Materials and methods: Forty CTC cases with flat lesions were retrospectively observed. The Subjects from a multicenter clinical trial underwent cathartic bowel preparation with orally administrated barium-based fecal-tagging. Sixty-nine flat lesions were confirmed using colonoscopy and histopathology as a reference standard. The results from SAEC reading were compared with those of prospective V3D and 2D readings. Results: Overall detection sensitivity with SAEC was 52% (36/69), which was statistically higher than that of 32% (22/69) and 29% (20/69) with V3D and 2D readings, respectively (p < 0.05). The sensitivities in detecting not-on-fold flat lesions were 63% (24/38), 45% (17/38), and 42% (16/38) with SAEC, V3D, and 2D readings, respectively; whereas those of on-fold flat lesions were 39% (12/31), 16% (5/31), and 13% (4/31), respectively. None of the eight flat lesions (2-9 mm) at cecum was detected by any of the three reading methods. Excluding the flat lesions at cecum, the sensitivity with SAEC for detecting flat lesion ≥4 mm increased to 84% (31/37). Conclusions: The fecal-tagging CTC with structure-analysis electronic cleansing could yield a high sensitivity for detecting flat lesions ≥4 mm. The not-on-fold flat lesions were detected with higher sensitivity than on-fold flat lesions.

  8. Cathodic detection of H2O2 based on nanopyramidal gold surface with enhanced electron transfer of myoglobin.

    Science.gov (United States)

    Xia, Peipei; Liu, Haiqing; Tian, Yang

    2009-04-15

    Direct and reversible electron transfer of myoglobin (Mb), for the first time, is achieved at nanopyramidal gold surface, which was fabricated by one-step electrodeposition, with redox formal potential of 0.21+/-0.01 V (vs. Ag/AgCl) and an apparent heterogeneous electron-transfer rate constant (k(s)) of 1.6+/-0.2 s(-1). Electrochemical investigation indicates that Mb is stably confined on the nanopyramidal gold surface and maintains electrocatalytic activity toward hydrogen peroxide (H(2)O(2)). The facilitated electron transfer combined with the intrinsic catalytical activity of Mb substantially construct the third-generation biosensor for H(2)O(2). The positive redox potential of Mb at the nanostructured gold electrode gives a strong basis for determination of H(2)O(2) with high selectivity. Besides this advantage, the present biosensor also exhibits quick response time, broad linear range, and good sensitivity. The dynamic detection linear range is from 1 microM to 1.4 mM with a detection limit of 0.5 microM at 3sigma. The striking analytical performance of the present biosensor, as well as the biocompatibility of gold nanostructures provided a potential for continuous, on-line detection of H(2)O(2) in the biological system.

  9. The Tendency of the Crest Factor Helps Detect Nascent Events; Electronic Circuit, Software and Applications to Signals from Diverse Fields

    Directory of Open Access Journals (Sweden)

    Núñez-Pérez Ricardo Francisco

    2014-04-01

    Full Text Available Within the signal analysis techniques in the time domain, the crest factor (CF is undoubtedly one of the most simple and fast to implement using electronic circuits and/or software. That's why it has been used reliably to care for machinery and to evaluate the quality of supply. One of the major manufacturers of instruments for these purposes is Bruel and Kjaer and defines the crest factor of voltage or repetitive current signal as the ratio of the peak level and its rms value during a certain period of time. In this paper, we try to find out experimentally the potential of CF and their tendency to detect the nascent and evolution of events in various fields of knowledge, either by generating it with a developed electronic circuit, or with calculations, through routines that are performed with the programs DADISP and LabVIEW. The results are validated and checked for all the above factors and trends through a comparison between them and the proposed features and specifications. The results were acceptable so that the tools were applied to detect early faults in electrical machines, to identify chaosity differences between the circuits with these dynamics, to detect abnormal respiratory distress or rales in patients and to detect harmful distortions in the electrical current, all this based on simulations and measurements for each of the 4 cases studied. Other CF original applications proposed are: a control of chaos in electronic circuits that stir/ mix industrial processes and b correct the power factor of non-linear and inductive loads. A medium-term study and use a CF that considers the maximum signal peak to peak is contemplated, and it is thought that it can improve event detection

  10. Quantitative detection of gold nanoparticles on individual, unstained cancer cells by Scanning Electron Microscopy

    NARCIS (Netherlands)

    Hartsuiker, Liesbeth; van Es, Peter; Petersen, Wilhelmina; van Leeuwen, Ton; Terstappen, Leonardus Wendelinus Mathias Marie; Otto, Cornelis

    2011-01-01

    Gold nanoparticles are rapidly emerging for use in biomedical applications. Characterization of the interaction and delivery of nanoparticles to cells through microscopy is important. Scanning electron microscopes have the intrinsic resolution to visualize gold nanoparticles on cells. A novel sample

  11. Quantitative detection of gold nanoparticles on individual, unstained cancer cells by scanning electron microscopy

    NARCIS (Netherlands)

    Hartsuiker, L.; van Es, P.; Petersen, W.; van Leeuwen, T. G.; Terstappen, L. W. M. M.; Otto, C.

    2011-01-01

    Gold nanoparticles are rapidly emerging for use in biomedical applications. Characterization of the interaction and delivery of nanoparticles to cells through microscopy is important. Scanning electron microscopes have the intrinsic resolution to visualize gold nanoparticles on cells. A novel sample

  12. Angle-resolved photoelectron spectrometry: new electron optics and detection system

    International Nuclear Information System (INIS)

    Hoof, H.A. van.

    1980-01-01

    A new spectrometer system is described, designed to measure angle-resolved energy distributions of photoemitted electrons efficiently. Some results are presented of measurements on a Si(001) surface. (Auth.)

  13. Application of CTOF method to detect secondly charged particle from 2 GeV electron

    International Nuclear Information System (INIS)

    Takahashi, Kazutoshi; Sanami, Toshiya; Ban, Syuichi; Lee, Hee-Seok; Sato, Tatsuhiko

    2002-01-01

    To design a shield and evaluate leakage radiation at high energy electron accelerators, the energy and angular data of secondary particle from the reaction of electrons with structural materials are required. Secondly neutron spectrum from structural materials has been measured by using electron accelerator in PAL (Pohang Accelerator Laboratory). In the neutron measurement, the electronics with Multi-hit TDC (MHTDC) was adopted to measure Time of Flight of every particles (TOFs) emitted from the reactions by each single electron bunch. The measurements are extended to secondly charged particles. For the charged particles measurement, the pulse height data for every particles are indispensable to distinguish charged particles by Δ E-E method. A new system which can measure pulse height for every particle is required instead of the MHTDC system. For this requirement, the method which can take output current from detectors was developed by using digital storage oscilloscope system is named ''Current Time of Flight method'' (CTOF). The CTOF method is able to measure pulse height and TOF for every particles produced by single electron bunch. Electrons are accelerated to 2.04 GeV and the repetition rate is 10 Hz. These electrons bombard thin disk samples of Cu 1mm, Al 4 mm and W 0.5 mm. Secondly charged particles, proton and deuteron, are produced in the samples by photonuclear reaction. Two dimensional of Δ E-E spectrum for each the samples measured by CTOF shows separation between proton and deuteron perfectly. Thus, proton and deuteron spectrum are obtained from this data. (M. Suetake)

  14. Scope and limitations of the TEMPO/EPR method for singlet oxygen detection: the misleading role of electron transfer.

    Science.gov (United States)

    Nardi, Giacomo; Manet, Ilse; Monti, Sandra; Miranda, Miguel A; Lhiaubet-Vallet, Virginie

    2014-12-01

    For many biological and biomedical studies, it is essential to detect the production of (1)O2 and quantify its production yield. Among the available methods, detection of the characteristic 1270-nm phosphorescence of singlet oxygen by time-resolved near-infrared (TRNIR) emission constitutes the most direct and unambiguous approach. An alternative indirect method is electron paramagnetic resonance (EPR) in combination with a singlet oxygen probe. This is based on the detection of the TEMPO free radical formed after oxidation of TEMP (2,2,6,6-tetramethylpiperidine) by singlet oxygen. Although the TEMPO/EPR method has been widely employed, it can produce misleading data. This is demonstrated by the present study, in which the quantum yields of singlet oxygen formation obtained by TRNIR emission and by the TEMPO/EPR method are compared for a set of well-known photosensitizers. The results reveal that the TEMPO/EPR method leads to significant overestimation of singlet oxygen yield when the singlet or triplet excited state of the photosensitizer is efficiently quenched by TEMP, acting as electron donor. In such case, generation of the TEMP(+) radical cation, followed by deprotonation and reaction with molecular oxygen, gives rise to an EPR-detectable TEMPO signal that is not associated with singlet oxygen production. This knowledge is essential for an appropriate and error-free application of the TEMPO/EPR method in chemical, biological, and medical studies. Copyright © 2014 Elsevier Inc. All rights reserved.

  15. Design of electronic measurement and quench detection equipment for the Current Lead Test facility Karlsruhe (CuLTKa)

    International Nuclear Information System (INIS)

    Hollik, Markus; Fietz, Walter H.; Fink, Stefan; Gehrlein, Mirko; Heller, Reinhard; Lange, Christian; Möhring, Tobias

    2013-01-01

    The Current Lead Test facility Karlsruhe (CuLTKa) is under construction at the Karlsruhe Institute of Technology (KIT) to perform acceptance tests of high temperature superconductor (HTS) current leads (CL). CuLTKa is in progress and present planning expects the completion in 2013. The data acquisition system is based on a modular design with electronic measurement and monitoring equipment covering a test voltage of 50 kV DC against ground. It provides plug-in units which enable temperature and voltage measurement at high voltage potential and in addition quench detection units which detect a loss of superconductivity reliably and quickly to avoid damage of the superconducting device under test. Prototype units for quench detection, temperature and voltage measurement have been successfully tested. Six temperature measurement units are already in use in the KIT test facility TOSKA and operated reliably during the acceptance tests of the HTS current leads for Wendelstein 7-X (W7-X) in 2011/2012. CuLTKa will be used first for 26 current leads which will be built in KIT for the fusion experiment JT-60SA. The present paper gives an overview of the design of the electronic measurement and quench detection equipment

  16. Failure detection of liquid cooled electronics in sealed packages. [in airborne information management system

    Science.gov (United States)

    Hoadley, A. W.; Porter, A. J.

    1991-01-01

    The theory and experimental verification of a method of detecting fluid-mass loss, expansion-chamber pressure loss, or excessive vapor build-up in NASA's Airborne Information Management System (AIMS) are presented. The primary purpose of this leak-detection method is to detect the fluid-mass loss before the volume of vapor on the liquid side causes a temperature-critical part to be out of the liquid. The method detects the initial leak after the first 2.5 pct of the liquid mass has been lost, and it can be used for detecting subsequent situations including the leaking of air into the liquid chamber and the subsequent vapor build-up.

  17. Single step synthesis of chitin/chitosan-based graphene oxide–ZnO hybrid composites for better electrical conductivity and optical properties

    International Nuclear Information System (INIS)

    Anandhavelu, S.; Thambidurai, S.

    2013-01-01

    Highlights: ► UV absorption at 260–360 nm confirmed strong binding of ZnO with chitosan–GO sheets. ► Chitin-based GO–ZnO shows higher electrical conductivity than chitosan-based GO–ZnO. ► Chitin-based GO–ZnO will useful in sensing, catalysis and energy storage applications. -- Abstract: We synthesized two composites/hybrid composites with a graphene oxide (GO)/mixed GO–ZnO filler using either a chitin or a chitosan matrix. Fourier transform infrared spectroscopy analysis confirmed that chitin had been converted to chitosan during matrix fabrication because only chitosan, ZnO and GO were shown to be present in the composites/hybrid composites. Raman spectroscopy indicated the display of D and G bands at 1345 cm −1 and 1584 cm −1 , respectively. UV absorption peaks appeared at 260–360 nm and 201 nm in both hybrid composites, which indicate a strong binding of ZnO within the chitosan–GO sheets. High resolution scanning electron microscopy and atomic force microscopy studies demonstrated that on a molecular scale ZnO was well dispersed in the hybrid composites. Impedance spectroscopy and a four-probe resistivity method were used for room temperature electrical conductivity measurements. The electrical conductivity of the chitin-based GO–ZnO hybrid composites was estimated to be ∼5.94 × 10 6 S/cm and was greater than that of the chitosan-based GO–ZnO hybrid composite (∼4.13 × 10 6 S/cm). The chitin-based GO–ZnO hybrid composite had a higher optical band gap (3.4 eV) than the chitosan-based GO–ZnO hybrid composite (3.0 eV). The current–voltage measurement showed that electrical sheets resistance of the chitosan-based composites decreased with formation of ZnO

  18. Single-Step Incubation Determination of miRNAs in Cancer Cells Using an Amperometric Biosensor Based on Competitive Hybridization onto Magnetic Beads

    Directory of Open Access Journals (Sweden)

    Eva Vargas

    2018-03-01

    Full Text Available This work reports an amperometric biosensor for the determination of miRNA-21, a relevant oncogene. The methodology involves a competitive DNA-target miRNA hybridization assay performed on the surface of magnetic microbeads (MBs and amperometric transduction at screen-printed carbon electrodes (SPCEs. The target miRNA competes with a synthetic fluorescein isothiocyanate (FITC-modified miRNA with an identical sequence for hybridization with a biotinylated and complementary DNA probe (b-Cp immobilized on the surface of streptavidin-modified MBs (b-Cp-MBs. Upon labeling, the FITC-modified miRNA attached to the MBs with horseradish peroxidase (HRP-conjugated anti-FITC Fab fragments and magnetic capturing of the MBs onto the working electrode surface of SPCEs. The cathodic current measured at −0.20 V (versus the Ag pseudo-reference electrode was demonstrated to be inversely proportional to the concentration of the target miRNA. This convenient biosensing method provided a linear range between 0.7 and 10.0 nM and a limit of detection (LOD of 0.2 nM (5 fmol in 25 μL of sample for the synthetic target miRNA without any amplification step. An acceptable selectivity towards single-base mismatched oligonucleotides, a high storage stability of the b-Cp-MBs, and usefulness for the accurate determination of miRNA-21 in raw total RNA (RNAt extracted from breast cancer cells (MCF-7 were demonstrated.

  19. Creation of an Accurate Algorithm to Detect Snellen Best Documented Visual Acuity from Ophthalmology Electronic Health Record Notes.

    Science.gov (United States)

    Mbagwu, Michael; French, Dustin D; Gill, Manjot; Mitchell, Christopher; Jackson, Kathryn; Kho, Abel; Bryar, Paul J

    2016-05-04

    Visual acuity is the primary measure used in ophthalmology to determine how well a patient can see. Visual acuity for a single eye may be recorded in multiple ways for a single patient visit (eg, Snellen vs. Jäger units vs. font print size), and be recorded for either distance or near vision. Capturing the best documented visual acuity (BDVA) of each eye in an individual patient visit is an important step for making electronic ophthalmology clinical notes useful in research. Currently, there is limited methodology for capturing BDVA in an efficient and accurate manner from electronic health record (EHR) notes. We developed an algorithm to detect BDVA for right and left eyes from defined fields within electronic ophthalmology clinical notes. We designed an algorithm to detect the BDVA from defined fields within 295,218 ophthalmology clinical notes with visual acuity data present. About 5668 unique responses were identified and an algorithm was developed to map all of the unique responses to a structured list of Snellen visual acuities. Visual acuity was captured from a total of 295,218 ophthalmology clinical notes during the study dates. The algorithm identified all visual acuities in the defined visual acuity section for each eye and returned a single BDVA for each eye. A clinician chart review of 100 random patient notes showed a 99% accuracy detecting BDVA from these records and 1% observed error. Our algorithm successfully captures best documented Snellen distance visual acuity from ophthalmology clinical notes and transforms a variety of inputs into a structured Snellen equivalent list. Our work, to the best of our knowledge, represents the first attempt at capturing visual acuity accurately from large numbers of electronic ophthalmology notes. Use of this algorithm can benefit research groups interested in assessing visual acuity for patient centered outcome. All codes used for this study are currently available, and will be made available online at https://phekb.org.

  20. [Electron microscopic detection rate of enteral viruses in diarrhea of dogs, cats, calves, swine and foals in the year 1988--electron microscopic study results].

    Science.gov (United States)

    Biermann, U; Herbst, W; Krauss, H; Schliesser, T

    1989-12-01

    During 1988 fecal and gut samples of 641 dogs, 198 cats, 576 calves, 108 piglets and 64 foals with diarrhoea were investigated for virus infections by electron microscopy. In samples of dogs and cats parvovirus was detected at a proportion of 21.9% and 16.7%, respectively; rotavirus alone or together with coronavirus was found only in 0.3-1.5% of the specimens. In samples of calves rotavirus, as well as coronavirus dominated with a detection rate amounting to 17.4% and 26.6% respectively (including 4.5% of mixed infections); parvovirus was present in a ratio of 0.5%. Specimens of piglets mainly contained coronavirus (25.0%), and in lower percentages rotavirus (2.8%), rota- and coronaviruses (0.9%) and parvovirus (0.9%). In feces of foals rotavirus was detected in 6.3% and particles resembling picornavirus in 4.7% of cases. Not identifiable virus particles resembling corona-or picornaviruses were rarely found (between 0.6-2.5) also in specimens of the other animal species.

  1. Parallel electric fields detected via conjugate electron echoes during the Echo 7 sounding rocket flight

    Science.gov (United States)

    Nemzek, R. J.; Winckler, J. R.

    1991-01-01

    Electron detectors on the Echo 7 active sounding rocket experiment measured 'conjugate echoes' resulting from artificial electron beam injections. Analysis of the drift motion of the electrons after a complete bounce leads to measurements of the magnetospheric convection electric field mapped to ionospheric altitudes. The magnetospheric field was highly variable, changing by tens of mV/m on time scales of as little as hundreds of millisec. While the smallest-scale magnetospheric field irregularities were mapped out by ionospheric conductivity, larger-scale features were enhanced by up to 50 mV/m in the ionosphere. The mismatch between magnetospheric and ionspheric convection fields indicates a violation of the equipotential field line condition. The parallel fields occurred in regions roughly 10 km across and probably supported a total potential drop of 10-100 V.

  2. A biosensor for hydrogen peroxide detection based on electronic properties of carbon nanotubes

    Science.gov (United States)

    Majidi, Roya

    2013-01-01

    Density functional theory has been used to study the effect of hydrogen peroxide on the electronic properties of single walled carbon nanotubes. The metallic and semiconducting carbon nanotubes have been considered in the presence of different number of hydrogen peroxide. The results indicate that hydrogen peroxide has no significant effect on the metallic nanotube and these nanotubes remain to be metallic. In contrast, the electronic properties of the semiconducting nanotubes are so sensitive to hydrogen peroxide. The energy band gap of these nanotubes is decreased by increasing the number of hydrogen peroxide. The electronic sensivity of the carbon nanotubes to hydrogen peroxide opens new insights into developing biosensors based on the single walled carbon nanotubes.

  3. Measurement of free neutron lifetime by electron decay detection with a migration chamber

    International Nuclear Information System (INIS)

    Grivot, P.

    1988-01-01

    In this study, the different aspects of the realization of the experimental setup are successively described: creation of a pulsed monochromatic neutron beam, design and construction of a detector for neutron decay electrons, development of electronics and of the data acquisition system, measurement of the helium-3 density in a gaseous mixture. A mechanical system called double chopper and a monochromator crystal are used to obtain neutron bursts with a length of about 28 cm and a velocity of 846 m/s. The electron detector is a time projection chamber (TPC) filled at atmospheric pressure with a helium-4 (93%), helium-3 (10 -5 %) and carbon dioxide (7%) mixture. The problems encountered during the data acquisition with the neutron beam and preliminary results from analysis are also presented [fr

  4. A technique for rocket-borne detection of electron bunching at megahertz frequencies

    International Nuclear Information System (INIS)

    Gough, M.P.

    1980-01-01

    Energetic electrons precipitating in the auroral ionosphere may be bunched at frequencies up to several megahertz as a result of local wave-particle interactions. A technique is described whereby this megahertz bunching can be observed using conventional rocket-borne energetic electron detectors counting at rates below 10 5 cps. Electron arrival time information is pre-processed on board the rocket and any bunching present can be realized by subsequent computer processing on the ground using only a modest data transmission rate from the rocket. Results of a pilot rocket experiment prove the value of the technique and lead on to formulating the design of a future experiment where the maximum amount of data processing is performed on the rocket. The technique should perform an important diagnostic role, helping us to understand the complex wave-particle interactions occurring in the auroral ionosphere. (orig.)

  5. Application of PIN photodiodes on the detection of X-rays generated in an electron accelerator

    International Nuclear Information System (INIS)

    Mondragon-Contreras, L.; Ramirez-Jimenez, F.J.; Garcia-Hernandez, J.M.; Torres-Bribiesca, M.A.; Lopez-Callejas, R.; Aguilera-Reyes, E.F.; Pena-Eguiluz, R.; Lopez-Valdivia, H.; Carrasco-Abrego, H.

    2009-01-01

    PIN photodiodes are used in a novel application for the determination, within the energy range from 90 to 485 keV, of the intensity of X-rays generated by an experimental electron accelerator. An easily assembled X-ray monitor has been built with a low-cost PIN photodiode and operational amplifiers. The output voltage signal obtained from this device can be related to the electron beam current and the accelerating voltage of the accelerator in order to estimate the dose rate delivered by bremsstrahlung.

  6. Interplanetary magnetic field orientations associated with bidirectional electron heat fluxes detected at ISEE 3

    International Nuclear Information System (INIS)

    Stansberry, J.A.; Gosling, J.T.; Thomsen, M.F.; Bame, S.J.; Smith, E.J.

    1988-01-01

    A statistical survey of interplanetary magnetic field orientations associated with bidirectional electron heat fluxes observed at ISEE 3 in orbit about the Sunward Lagrange point indicates that magnetic connection of the spacecraft to the Earth's bow shock was frequently the source of the bidirectionality. When the interplanetary magnetic field was oriented within 5 0 of the Earth-spacecraft line, backstreaming electrons from the bow shock were clearly observed approximately 18% of the time, and connections apparently occurred for angles as large as ∼30 0 --35 0 . copyright American Geophysical Union 1988

  7. Detection efficiency for radionuclides decaying by electron capture and gamma-Ray

    International Nuclear Information System (INIS)

    Grau, A.; Fernandez, A.

    1985-01-01

    In this paper, the electron capture partial counting efficiency vs the figure of merit for electron-capture and gamma-ray emitters has been computed. The radionuclides tabulated are 48 c r, 54 M n, 57 C o 56 N i, 72 S e, 73 A s, 85 S r, 88 Z r, 92 N b, 103 P d, 111 l n, 119 S b, 125 I , 139 C e and 152 D y. It has been assumed that the liquid is a toluene based scintillator solution in standard glass vials containing 15 cm 3 . (Author) 17 refs

  8. A multiplex reverse transcription PCR and automated electronic microarray assay for detection and differentiation of seven viruses affecting swine.

    Science.gov (United States)

    Erickson, A; Fisher, M; Furukawa-Stoffer, T; Ambagala, A; Hodko, D; Pasick, J; King, D P; Nfon, C; Ortega Polo, R; Lung, O

    2018-04-01

    Microarray technology can be useful for pathogen detection as it allows simultaneous interrogation of the presence or absence of a large number of genetic signatures. However, most microarray assays are labour-intensive and time-consuming to perform. This study describes the development and initial evaluation of a multiplex reverse transcription (RT)-PCR and novel accompanying automated electronic microarray assay for simultaneous detection and differentiation of seven important viruses that affect swine (foot-and-mouth disease virus [FMDV], swine vesicular disease virus [SVDV], vesicular exanthema of swine virus [VESV], African swine fever virus [ASFV], classical swine fever virus [CSFV], porcine respiratory and reproductive syndrome virus [PRRSV] and porcine circovirus type 2 [PCV2]). The novel electronic microarray assay utilizes a single, user-friendly instrument that integrates and automates capture probe printing, hybridization, washing and reporting on a disposable electronic microarray cartridge with 400 features. This assay accurately detected and identified a total of 68 isolates of the seven targeted virus species including 23 samples of FMDV, representing all seven serotypes, and 10 CSFV strains, representing all three genotypes. The assay successfully detected viruses in clinical samples from the field, experimentally infected animals (as early as 1 day post-infection (dpi) for FMDV and SVDV, 4 dpi for ASFV, 5 dpi for CSFV), as well as in biological material that were spiked with target viruses. The limit of detection was 10 copies/μl for ASFV, PCV2 and PRRSV, 100 copies/μl for SVDV, CSFV, VESV and 1,000 copies/μl for FMDV. The electronic microarray component had reduced analytical sensitivity for several of the target viruses when compared with the multiplex RT-PCR. The integration of capture probe printing allows custom onsite array printing as needed, while electrophoretically driven hybridization generates results faster than conventional

  9. Electronically tuned sulfonamide-based probes with ultra-sensitivity for Ga"3"+ or Al"3"+ detection in aqueous solution

    International Nuclear Information System (INIS)

    Kumar, Ashwani; Chae, Pil Seok

    2017-01-01

    Three electronically tuned fluorescent probes (1–3) were synthesized by conjugating a fluorescent unit to N,N-bis-(hydroxyethyl)ethylenediamine. Probe 1 bearing an electron-deficient naphthalenedimide unit did not give a fluorescence response to the presence of various metal ions including monovalent metal ions (Na"+, K"+, and Ag"+), divalent metal ions (Ca"2"+, Cd"2"+, Co"2"+, Ni"2"+, Cu"2"+, Hg"2"+, Pb"2"+, and Zn"2"+) and trivalent metal ions (Al"3"+, Ga"3"+, Fe"3"+, and Cr"3"+) in an aqueous solution. By contrast, probes 2 and 3 possessing 1,8-naphthalimide and pyrene fluorophores, respectively, exhibited selective fluorescent “OFF-ON” behaviors as a result of Ga"3"+/Al"3"+ binding among the diverse metal ions, suggesting the importance of fluorophore electronic character with regard to metal ion sensing. The ethylenediamine analog of probe 3, corresponding to probe 4, was unable to yield a significant change in fluorescence intensity in the presence of any metal ions tested here, revealing the essential role of two hydroxyl groups for metal ion binding. A high association constant of K_a = 2.99 × 10"5 M"−"1 was obtained for probe 3 with Ga"3"+, with a limit of detection (LOD) of 10 nM. This LOD is the lowest value known for Ga"3"+ detection using chemical sensors. Along with an increase in aggregate sizes, PET suppression of probes upon metal ion binding was the primary contributor to the enhancement in fluorescence emission necessary for the sensitive detection of the target ions. The probe-metal ion complexes were fully characterized via TEM, FE-SEM, "1H NMR, fluorescence spectroscopy techniques and DFT calculations. - Highlights: • Three electronically tuned sulfonamide-based probes (probes 1, 2, and 3) were developed for metal ion-sensing. • Probes 2 and 3 exhibited AIE behavior with increasing water-content. • Probes 2 and 3 displayed a selective fluorescence “OFF-ON“ behavior for Ga"3"+ detection with the LOD of 10 nM. • PET

  10. Electron Spin Polarization and Detection in InAs Quantum Dots Through p-Shell Trions

    Science.gov (United States)

    2010-01-08

    optical control of spin states in quantum dots. II. EXPERIMENT The QD sample consists of 20 layers of InAs QDs, grown by molecular -beam epitaxy through...anisotropic 2D harmonic poten- tials. The electrons and holes are described by Fock- Darwin states harmonic oscillators with lateral sizes ax and ay in this

  11. A new method for detecting the contribution of high Rydberg states to electron-ion recombination

    International Nuclear Information System (INIS)

    Orban, I; Boehm, S; Fogle, M; Paal, A; Schuch, R

    2007-01-01

    A position sensitive detector for measuring field ionized electrons in the fringe field of a dipole magnet is presented. The detector provides a means to study, in a state selective fashion, recombination into high Rydberg states and offers a new method to investigate recombination enhancement effects. Several experimental considerations and possibilities are discussed in the text

  12. Resonant plasmonic terahertz detection in vertical graphene-base hot-electron transistors

    Energy Technology Data Exchange (ETDEWEB)

    Ryzhii, V. [Research Institute of Electrical Communication, Tohoku University, Sendai 980-8577 (Japan); Center for Photonics and Infrared Engineering, Bauman Moscow State Technical University and Institute of Ultra High Frequency Semiconductor Electronics of RAS, Moscow 111005 (Russian Federation); Otsuji, T. [Research Institute of Electrical Communication, Tohoku University, Sendai 980-8577 (Japan); Ryzhii, M. [Department of Computer Science and Engineering, University of Aizu, Aizu-Wakamatsu 965-8580 (Japan); Mitin, V. [Department of Electrical Engineering, University at Buffalo, SUNY, Buffalo, New York 1460-1920 (United States); Shur, M. S. [Department of Electrical, Computer, and System Engineering and Physics, Applied Physics, and Astronomy, Rensselaer Polytechnic Institute, Troy, New York 12180 (United States)

    2015-11-28

    We analyze dynamic properties of vertical graphene-base hot-electron transistors (GB-HETs) and consider their operation as detectors of terahertz (THz) radiation using the developed device model. The GB-HET model accounts for the tunneling electron injection from the emitter, electron propagation across the barrier layers with the partial capture into the GB, and the self-consistent oscillations of the electric potential and the hole density in the GB (plasma oscillations), as well as the quantum capacitance and the electron transit-time effects. Using the proposed device model, we calculate the responsivity of GB-HETs operating as THz detectors as a function of the signal frequency, applied bias voltages, and the structural parameters. The inclusion of the plasmonic effect leads to the possibility of the GB-HET operation at the frequencies significantly exceeding those limited by the characteristic RC-time. It is found that the responsivity of GB-HETs with a sufficiently perfect GB exhibits sharp resonant maxima in the THz range of frequencies associated with the excitation of plasma oscillations. The positions of these maxima are controlled by the applied bias voltages. The GB-HETs can compete with and even surpass other plasmonic THz detectors.

  13. Detection of beryllium in oxides and silicates by electron-probe microanalysis

    Directory of Open Access Journals (Sweden)

    V. V. Khiller

    2017-12-01

    Full Text Available The author developed the technique of electron-probe microanalysis for quantitative determination of beryllium content, providing the example of studying natural minerals (aluminosilicates and oxides. This technique allowed to obtain a quantitative content of beryllium (in combination with other elements in the emeralds of the Mariinsky beryllium deposit and in zonal mariinskite-chrysoberyl from the chromitites of the Bazhenov ophiolite complex. All analyzes of minerals were performed on a CAMECA SX 100 electron probe microanalyzer with five wave spectrometers (IGG UB RAS. The pressure in the sample chamber was 2 × 10–4 Pa, in the electron gun region – 4 × 10–6 Pa, in wave spectrometers – 7 Pa. Accelerating voltage was 10 kV, the current of absorbed electrons on the Faraday cylinder (beam current was 100–150 nA. Diameter of the electron beam focused on the sample was 2 μm, the angle of x-ray extraction was 40°. The spectra were obtained on wave spectrometers with TAP crystal analyzers (2d = 25.745 Å, LPET (2d = 8.75 Å, LiF (2d = 4.0226 Å, and PC3 (2d = 211.4 Å, a specialized crystal for determining the content of beryllium and boron; the author carried out all the elements measurements along the Kα-lines. To determine position of the analytical peak and the background from two sides with the minimum possible spectral overlap, the author preliminarily recorded spectra on wave spectrometers. The obtained microprobe analyzes of minerals with quantitative determination of beryllium converge well with the available theoretical compositions of beryl and chrysoberyl, which indicates the high efficiency of the developed technique. By using this technique, we can relatively quickly and reliably determine the quantitative content of beryllium in natural silicates and oxides, which is an acute need for geological researchers studying the mineralogy of beryllium deposits.

  14. A novel signal-on photoelectrochemical immunosensor for detection of alpha-fetoprotein by in situ releasing electron donor.

    Science.gov (United States)

    Chen, Jiexia; Zhao, Guang-Chao

    2017-12-15

    A signal-on photoelectrochemical (PEC) immunosensor was constructed for detecting tumor marker in this work. α-fetoprotein (AFP) was chosen as a model analyte to investigate the prepared procedure and the analytical performance of the exploited sensor. In order to construct the sensor, CdSe QDs were used as photoactive material, biotin conjugated AFP antibody (Bio-anti-AFP) as detecting probe, streptavidin (SA) as signal capturing unit, biotin functionalized apoferritin encapsulated ascorbic acid (Bio-APOAA) as amplification unit, which were assembled onto the electrodes. The sensing strategy was based on in situ enzymatic hydrolysis of Bio-APOAA to release ascorbic acid (AA) as sacrificial electron donor to produce photocurrent. The photocurrent from the immunosensor was monitored as a result of AFP concentrations. The constructed sensing platform displayed high selectivity and good sensitivity for detecting AFP. Under optimal conditions, a wide linear range from 0.001 to 1000ng/mL and a low detection limit of 0.31pg/mL were obtained. The developed immunosensor is expected to be used to determine AFP and other tumor markers in human plasma in clinical laboratories either for pre-cancer screening or cancer monitoring. Moreover, this sensing platform further has the potential to use for the detection of trypsin activity and the corresponding inhibitor-screening. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Three-dimensional imaging of individual point defects using selective detection angles in annular dark field scanning transmission electron microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, Jared M.; Im, Soohyun; Windl, Wolfgang; Hwang, Jinwoo, E-mail: hwang.458@osu.edu

    2017-01-15

    We propose a new scanning transmission electron microscopy (STEM) technique that can realize the three-dimensional (3D) characterization of vacancies, lighter and heavier dopants with high precision. Using multislice STEM imaging and diffraction simulations of β-Ga{sub 2}O{sub 3} and SrTiO{sub 3}, we show that selecting a small range of low scattering angles can make the contrast of the defect-containing atomic columns substantially more depth-dependent. The origin of the depth-dependence is the de-channeling of electrons due to the existence of a point defect in the atomic column, which creates extra “ripples” at low scattering angles. The highest contrast of the point defect can be achieved when the de-channeling signal is captured using the 20–40 mrad detection angle range. The effect of sample thickness, crystal orientation, local strain, probe convergence angle, and experimental uncertainty to the depth-dependent contrast of the point defect will also be discussed. The proposed technique therefore opens new possibilities for highly precise 3D structural characterization of individual point defects in functional materials. - Highlights: • A new electron microscopy technique that can visualize 3D position of point defect is proposed. • The technique relies on the electron de-channeling signals at low scattering angles. • The technique enables precise determination of the depth of vacancies and lighter impurity atoms.

  16. Characterisation of a monolithic active pixel sensor for electron detection in the energy range 10-20 keV

    International Nuclear Information System (INIS)

    Matheson, J.; Moldovan, G.; Clark, A.; Prydderch, M.; Turchetta, R.; Derbyshire, G.; Kirkland, A.; Allinson, N.

    2009-01-01

    As part of a feasibility study into the use of novel electron detectors for X-ray photoelectron emission microscopes (XPEEM), we have characterised the imaging performance of a back-illuminated monolithic active pixel sensor (MAPS) operating under both integrating and counting modes for electrons in the energy range 10-20 keV. For integrating mode, we present the detective quantum efficiency (DQE), which shows marked improvements over conventional indirect detectors based on microchannel plates. We also present the modulation transfer function (MTF) and noise power spectrum (NPS), again demonstrating significantly improved performance. For counting mode, we present the quantum efficiency (QE) as a function of incident electron energy. We have evaluated the charge collection efficiency (CCE) and we thereby demonstrate the presence of a ∼200 nm thick dead layer that is linked with reduced CCE at low electron energies. Based on our findings, we believe that the MAPS technology is well matched to future XPEEM instruments using aberration correction.

  17. Oxidative stress detection by MEMS cantilever sensor array based electronic nose

    Science.gov (United States)

    Gupta, Anurag; Singh, T. Sonamani; Singh, Priyanka; Yadava, R. D. S.

    2018-05-01

    This paper is concerned with analyzing the role of polymer swelling induced surface stress in MEMS chemical sensors. The objective is to determine the impact of surface stress on the chemical discrimination ability of MEMS resonator sensors. We considered a case study of hypoxia detection by MEMS sensor array and performed several types of simulation experiments for detection of oxidative stress volatile organic markers in human breath. Both types of sensor response models that account for the surface stress effect and that did not were considered for the analyses in comparison. It is found that the surface stress (hence the polymer swelling) provides better chemical discrimination ability to polymer coated MEMS sensors.

  18. Sensitivity and spatial resolution for electron-spin-resonance detection by magnetic resonance force microscopy

    International Nuclear Information System (INIS)

    Zhang, Z.; Roukes, M.L.; Hammel, P.C.

    1996-01-01

    The signal intensity of electron spin resonance in magnetic resonance force microscopy (MRFM) experiments employing periodic saturation of the electron spin magnetization is determined by four parameters: the rf field H 1 , the modulation level of the bias field H m , the spin relaxation time τ 1 , and the magnetic size R(∂H/∂z) of the sample. Calculations of the MRFM spectra obtained from a 2,2-diphenyl-1-picrylhydrazyl particle have been performed for various conditions. The results are compared with experimental data and excellent agreement is found. The systematic variation of the signal intensity as a function of H 1 and H m provides a powerful tool to characterize the MRFM apparatus. copyright 1996 American Institute of Physics

  19. High-resolution broadband terahertz spectroscopy via electronic heterodyne detection of photonically generated terahertz frequency comb.

    Science.gov (United States)

    Pavelyev, D G; Skryl, A S; Bakunov, M I

    2014-10-01

    We report an alternative approach to the terahertz frequency-comb spectroscopy (TFCS) based on nonlinear mixing of a photonically generated terahertz pulse train with a continuous wave signal from an electronic synthesizer. A superlattice is used as a nonlinear mixer. Unlike the standard TFCS technique, this approach does not require a complex double-laser system but retains the advantages of TFCS-high spectral resolution and wide bandwidth.

  20. Electron precipitation induced by VLF noise bursts at the plasmapause and detected at conjugate ground stations

    International Nuclear Information System (INIS)

    Dingle, B.; Carpenter, D.L.

    1981-01-01

    A new type of wave-induced electron precipitation event has been identified. During observations at conjugate stations Siple, Antarctica, and Roberval, Canada (L-4.2), VLF noise bursts were found to be associated on a one-to-one basis with amplitude perturbations of subionispheric radio propagation. The amplitude perturbations are attributed to patches of enhanced ionization that extended below approx.80 km in the nighttime ionosphere and that were produced by precipitating electron bursts. Similar amplitude perturbations seen previously were correlated with whistlers that propagated within the plasmasphere. For the new events the driving waves were structured collections of rising elements that propagated just beyond the plasmapause at roughly 5-min intervals over a several-hour period. These noise bursts were of relatively long duration (approx.10 s) and strong intensity (inferred to be >30 pT at the equator). Triggering of the noise bursts appears to have been mostly by whistlers but changed in character with time. Some later bursts had narrowband precursors at constant frequencies possibly locked to power line harmonic radiation. The burst initiation characteristics suggest the existence of a variable threshold for rapid temporal growth in the magnetosphere controlled by the trapped electron dynamics. The temporal signatures of the amplitude perturbations show that precipitation was maintained over multiple bounces of the trapped magnetospheric electrons. In some cases these signatures include a new undershoot effect during the recovery phase lasting 2--5 min. This effect may have been related to cutoff of background drizzle precipitation. Precipitation effects were observed on both long (approx.10 Mm) and short (approx.1/2 Mm) subionospheric paths and were monitored simultaneously at the conjugate stations. Similarities in the perturbation signatures on long and short paths suggest that the form of the signatures was governed by ionospheric changes

  1. Development of a Portable Electronic Nose System for the Detection and Classification of Fruity Odors

    Directory of Open Access Journals (Sweden)

    Kea-Tiong Tang

    2010-10-01

    Full Text Available In this study, we have developed a prototype of a portable electronic nose (E-Nose comprising a sensor array of eight commercially available sensors, a data acquisition interface PCB, and a microprocessor. Verification software was developed to verify system functions. Experimental results indicate that the proposed system prototype is able to identify the fragrance of three fruits, namely lemon, banana, and litchi.

  2. Detection of electrons in the 10 MeV range by plastic scintillators

    Energy Technology Data Exchange (ETDEWEB)

    Beaudoin, G; Champagne, A; Jeremie, H; Lessard, L

    1986-09-10

    Response functions for electrons from 1 to 12 MeV have been measured with a plastic scintillator telescope. A parametrization model for these response functions has been found to give good results at all energies. Furthermore it was established that the type of reflector used for the scintillator has a considerable influence on the response functions. A mechanism for this influence has been proposed and tested by Monte Carlo calculations.

  3. Electron and hole photoemission detection for band offset determination of tunnel field-effect transistor heterojunctions

    International Nuclear Information System (INIS)

    Li, Wei; Zhang, Qin; Kirillov, Oleg A.; Levin, Igor; Richter, Curt A.; Gundlach, David J.; Nguyen, N. V.; Bijesh, R.; Datta, S.; Liang, Yiran; Peng, Lian-Mao; Liang, Xuelei

    2014-01-01

    We report experimental methods to ascertain a complete energy band alignment of a broken-gap tunnel field-effect transistor based on an InAs/GaSb hetero-junction. By using graphene as an optically transparent electrode, both the electron and hole barrier heights at the InAs/GaSb interface can be quantified. For a Al 2 O 3 /InAs/GaSb layer structure, the barrier height from the top of the InAs and GaSb valence bands to the bottom of the Al 2 O 3 conduction band is inferred from electron emission whereas hole emissions reveal the barrier height from the top of the Al 2 O 3 valence band to the bottom of the InAs and GaSb conduction bands. Subsequently, the offset parameter at the broken gap InAs/GaSb interface is extracted and thus can be used to facilitate the development of predicted models of electron quantum tunneling efficiency and transistor performance

  4. An atomic model of brome mosaic virus using direct electron detection and real-space optimization

    Science.gov (United States)

    Wang, Zhao; Hryc, Corey F.; Bammes, Benjamin; Afonine, Pavel V.; Jakana, Joanita; Chen, Dong-Hua; Liu, Xiangan; Baker, Matthew L.; Kao, Cheng; Ludtke, Steven J.; Schmid, Michael F.; Adams, Paul D.; Chiu, Wah

    2014-09-01

    Advances in electron cryo-microscopy have enabled structure determination of macromolecules at near-atomic resolution. However, structure determination, even using de novo methods, remains susceptible to model bias and overfitting. Here we describe a complete workflow for data acquisition, image processing, all-atom modelling and validation of brome mosaic virus, an RNA virus. Data were collected with a direct electron detector in integrating mode and an exposure beyond the traditional radiation damage limit. The final density map has a resolution of 3.8 Å as assessed by two independent data sets and maps. We used the map to derive an all-atom model with a newly implemented real-space optimization protocol. The validity of the model was verified by its match with the density map and a previous model from X-ray crystallography, as well as the internal consistency of models from independent maps. This study demonstrates a practical approach to obtain a rigorously validated atomic resolution electron cryo-microscopy structure.

  5. Detection and quantification of ochratoxin A and deoxynivalenol in barley grains by GC-MS and electronic nose.

    Science.gov (United States)

    Olsson, J; Börjesson, T; Lundstedt, T; Schnürer, J

    2002-02-05

    Mycotoxin contamination of cereal grains can be detected and quantified using complex extraction procedures and analytical techniques. Normally, the grain odour, i.e. the presence of non-grain volatile metabolites, is used for quality classification of grain. We have investigated the possibility of using fungal volatile metabolites as indicators of mycotoxins in grain. Ten barley samples with normal odour, and 30 with some kind of off-odour were selected from Swedish granaries. The samples were evaluated with regard to moisture content, fungal contamination, ergosterol content, and levels of ochratoxin A (OA) and deoxynivalenol (DON). Volatile compounds were also analysed using both an electronic nose and gas chromatography combined with mass spectrometry (GC-MS). Samples with normal odour had no detectable ochratoxin A and average DON contents of 16 microg kg(-1) (range 0-80), while samples with off-odour had average OA contents of 76 microg kg(-1) (range 0-934) and DON contents of 69 microg kg(-1) (range 0-857). Data were evaluated by multivariate data analysis using projection methods such as principal component analysis (PCA) and partial least squares (PLS). The results show that it was possible to classify the OA level as below or above the maximum limit of 5 microg kg(-1) cereal grain established by the Swedish National Food Administration, and that the DON level could be estimated using PLS. Samples with OA levels below 5 microg kg(-1) had higher concentration of aldehydes (nonanal, 2-hexenal) and alcohols (1-penten-3-ol, 1-octanol). Samples with OA levels above 5 microg kg(-1) had higher concentrations of ketones (2-hexanone, 3-octanone). The GC-MS system predicted OA concentrations with a higher accuracy than the electronic nose, since the GC-MS misclassified only 3 of 37 samples and the electronic nose 7 of 37 samples. No correlation was found between odour and OA level, as samples with pronounced or strong off-odours had OA levels both below and above 5

  6. Rapid detection of E. coli on goat meat by electronic nose

    Science.gov (United States)

    Much attention has been paid on the foodborne illness of food, which is easily contaminated with bacterial or pathogens. Escherichia coli (E. coli) is one of these bacterial that commonly live in the contaminated animal meat. There is a growing need in the food industry for pathogen detection syst...

  7. Examination of the Effects of Activated Carbon Produced from Coal Using Single-Step H3PO4/N2+H2O Vapor Activation on the Adsorption of Bovine Serum Albumin at Different Temperatures and pH Values

    Directory of Open Access Journals (Sweden)

    Atakan Toprak

    2017-12-01

    Full Text Available This study examined protein adsorption equilibrium and kinetics on activated carbon (AC that we obtained from coal by single-step H3PO4 activation under N2+H2O vapor at 800 °C. Surface properties, pore size distribution, and volumes of AC were determined using the volumetric method with N2 adsorption at 77 K. Also, the textural properties were characterized by SEM-EDAX and XRD. The zeta potential values were measured to elucidate the electrostatic interactions between the protein and AC. The obtained AC discrete system was also used as an adsorbent for adsorbing bovine serum albumin (BSA from aqueous solution. The effects of pH (4.0, 5.0, and 7.4 and temperatures (20, 30 and 40 °C on the adsorption of BSA on AC were examined. The surface area, micropore, mesopore and total pore volumes of AC were found to be 1175 m2/g, 0.477 cm3/g, 0.061 cm3/g and 0.538 cm3/g, respectively. The optimum temperature for AC in BSA adsorption was found to be 40 °C and the pH was found to be 4.0. The highest BSA adsorption was found to be 159 mg/g and pH to be 4.0. The experimental equilibrium data were compared with the Langmuir and Freundlich models and found to be compatible with both models. The adsorption process is best described by the pseudo-first-order kinetic model. As a result, it was found out that AC obtained by single step H3PO4/N2+H2O vapor activation is an effective adsorbent for the adsorption of BSA from aqueous solution.

  8. Electronic network for monitoring travellers' diarrhoea and detection of an outbreak caused by Salmonella enteritidis among overseas travellers.

    Science.gov (United States)

    Osaka, K; Inouye, S; Okabe, N; Taniguchi, K; Izumiya, H; Watanabe, H; Matsumoto, Y; Yokota, T; Hashimoto, S; Sagara, H

    1999-12-01

    The Traveller's Diarrhoea Network, by which the Infectious Disease Surveillance Center is electronically connected with two major airport quarantine stations and three infectious disease hospitals, was launched in February 1988 in Japan. The data on travellers' diarrhoea detected is reported weekly by e-mail. Two clusters of infection among travellers returning from Italy were reported by two airport quarantine stations at the end of September 1998. A total of 12 salmonella isolates from 2 clusters were examined. All were identified as Salmonella enteritidis, phage type 4 and showed identical banding patterns on pulsed-field gel electrophoresis. A case-control study showed that the scrambled eggs served at the hotel restaurant in Rome were the likely source of this outbreak. This outbreak could not have been detected promptly and investigated easily without the e-mail network. International exchange of data on travellers' diarrhoea is important for preventing and controlling food-borne illnesses infected abroad.

  9. Electronic Detection of DNA Hybridization by Coupling Organic Field-Effect Transistor-Based Sensors and Hairpin-Shaped Probes

    Directory of Open Access Journals (Sweden)

    Corrado Napoli

    2018-03-01

    Full Text Available In this paper, the electronic transduction of DNA hybridization is presented by coupling organic charge-modulated field-effect transistors (OCMFETs and hairpin-shaped probes. These probes have shown interesting properties in terms of sensitivity and selectivity in other kinds of assays, in the form of molecular beacons (MBs. Their integration with organic-transistor based sensors, never explored before, paves the way to a new class of low-cost, easy-to-use, and portable genetic sensors with enhanced performances. Thanks to the peculiar characteristics of the employed sensor, measurements can be performed at relatively high ionic strengths, thus optimizing the probes’ functionality without affecting the detection ability of the device. A complete electrical characterization of the sensor is reported, including calibration with different target concentrations in the measurement environment and selectivity evaluation. In particular, DNA hybridization detection for target concentration as low as 100 pM is demonstrated.

  10. Earth's magnetic field as a radiator to detect cosmic ray electrons of energy greater than 10 to the 12th eV

    Science.gov (United States)

    Balasubrahmanyan, V. K.; Stephens, S. A.

    1983-01-01

    Synchrotron emission by a high-energy electron in the geomagnetic field and its dependence upon different arrival directions over Palestine, Texas, where major balloon-borne experiments are being conducted, is studied. The dependence of detector response on the arrival direction of electron, the different criteria which are adopted to identify an electron event, the area of the detector, and the energy of the electron are discussed. An omnidirectional circular detector is used to examine whether it is possible to determine the energy of an electron without knowing its arrival direction. The collecting power of a detector is estimated as a function of the energy of electrons for different detector areas with different selection criteria, and this information is used to calculate the event rates expected by folding in the energy spectrum of cosmic ray electrons to show the viability of detecting cosmic ray electrons at energies greater than a few TeV.

  11. Guidelines on What Constitutes Plagiarism and Electronic Tools to Detect it.

    Science.gov (United States)

    Luksanapruksa, Panya; Millhouse, Paul W

    2016-04-01

    Plagiarism is a serious ethical problem among scientific publications. There are various definitions of plagiarism, and the major categories include unintentional (unsuitable paraphrasing or improper citations) and intentional. Intentional plagiarism includes mosaic plagiarism, plagiarism of ideas, plagiarism of text, and self-plagiarism. There are many Web sites and software packages that claim to detect plagiarism effectively. A violation of plagiarism laws can lead to serious consequences including author banning, loss of professional reputation, termination of a position, and even legal action.

  12. Novel Electron Spin Resonance-Enzyme Immunosorbent Assay for Detecting Occult Hepatitis B Infection in HCV Chronic Liver Disease

    Directory of Open Access Journals (Sweden)

    Hala Badawi

    2017-11-01

    Full Text Available Background: Hepatitis B virus infection in patients who lack detectable hepatitis B surface antigen (HBsAg is called occult hepatitis B infection (OHB. The very low level of HBV genome may hamper its detection by molecular techniques. Recently, a highly sensitive EIA utilizing a novel modified electron spin resonance (ESR technique (modified ESR-EIA was developed to detect HBsAg by measuring stabilized nitroxide radicals. Aim: to detect occult HBV infection, using ESR-EIA among HCV-related chronic liver disease (CLD Egyptian patients who were seronegative for HBsAg by standard EIA. Methods: The study was conducted on two periods of time; in 1st period, 72 inpatients in Tropical Medicine Department of TBRI, were enrolled in the study. They were divided into two groups; 44 seropositive anti-HCV patients (Group I, 28 seronegative anti-HCV patients (Group II. Sera were subjected to virological assays for HBsAg, HBeAg, anti-HBc IgM, anti-HBc IgG, anti-HBs, anti-HCV and HCV RNA. We also examined serum HBV DNA by polymerase chain reaction (PCR technique and real-time detection polymerase chain reaction (RTD-PCR. In the 2nd period; modified ESR-EIA was applied on 32 TBRI inpatients, 23 in Tropical Medicine Department (Group I and 9 from hemodialysis unit (Group II with HCV-related CLD. Results: OHB was detected in 18.1% and 86.9% of our patients in 2002 and 2006 respectively. In phase 1, there was a higher detection rate among HCV patients in Group I (25% than Group II (7%, with higher prevalence (52.4% in patients with positive HCV RNA in Group I versus those with negative HCV viremia (8% in Group II. HBV DNA by either PCR or RTD-PCR was negative in all patients of both groups as the HBV viral load of the samples were below detectable level of the methods used; less than 100 copies/ml. None of 9 hemodialysis patients were positive for OHB. Conclusion: The newly developed quantitative ESR-EIA technique represents a great evolution for screening and

  13. YBCO hot-electron bolometers dedicated to THz detection and imaging: Embedding issues

    International Nuclear Information System (INIS)

    Aurino, M; Tuerer, I; Martinez, A; Gensbittel, A; Degardin, A F; Kreisler, A J

    2010-01-01

    High-T c hot-electron bolometers (HEB) are an interesting alternative to other superconducting heterodyne mixers in the terahertz frequency range because of low-cost cooling investment, ultra-wide instantaneous bandwidth and low intrinsic noise level, even at 80 K. A technological process to fabricate stacked yttrium-based (YBCO) / praseodymium-based (PBCO) ultra-thin films (in the 15 to 40 nm thickness range) etched to form 0.5 μm x 0.5 μm constrictions, elaborated on (100) MgO substrates, has been previously described. Ageing effects were also considered, with the consequence of increased electrical resistance, significant degradation of the regular THz response and no HEB mixing action. Electron and UV lithography steps are revisited here to realize HEB mixers based on nano-bridges covered by a log-periodic planar gold antenna, dedicated to the 1 to 7 THz range. Several measures have been attempted to reduce the conversion losses, mainly by considering the embedding issues related to the YBCO nano-bridge impedance matching to the antenna and the design of optimized intermediate frequency circuitry. Antenna simulations were performed and validated through experiments on scaled models at GHz frequencies. Electromagnetic coupling to the incoming radiation was also studied, including crosstalk between neighbour antennas forming a linear imaging array.

  14. Determination of DDTs and PCBs by capillary gas chromatography and electron capture detection

    International Nuclear Information System (INIS)

    1988-01-01

    This reference method deals with the determination of DDTs and PCBs in marine environmental samples using high resolution gas chromatography. Several other halogenated pesticides and other electron capturing organic compounds may be present in samples and many of these may also be determined by this method. Not all electron capturing residues will be resistant to all of the clean up procedures described here for the analysis of DTTs and PCBs. Therefore, additional information on the stability of some common pesticides using this methodology is also provided. The high separation power of open tubular (''capillary'') columns allows the identification and quantification of many compounds in the complex mixtures occurring in environmental samples. This manual provides information on the theoretical and practical aspects of the use of these high resolution columns for the analysis of DDTs and PCBs in environmental samples. The qualitative and quantitative method can be applied to any sample type (aerosol/vapour, water, particulates, biota, etc.) provided that suitable cleaned-up extracts dissolved in n-hexane are available for injection into the GC system. For example, methods for obtaining these cleaned-up sample extracts from marine organisms are described in detail in UNEP Reference Method no. 14 and for sediments in No. 17. The change in the field of application by analysing by capillary rather than packed columns may be less dramatic for DDTs. However, with the increased separation, the possibilities of inaccurate analysis resulting from overlap with interfering compounds is reduced. 7 refs, 1 fig., 3 tabs

  15. Detection of oxygen-related defects in GaAs by exo-electron emission spectroscopy

    Science.gov (United States)

    Hulluvarad, Shiva S.; Naddaf, M.; Bhoraskar, S. V.

    2001-10-01

    The influence of intentional introduction of oxygen, at the surface of GaAs, on its native surface states was studied. Oxygen was made to interact with the surface of GaAs by three different means: (1) by growing native oxides, (2) exposing to oxygen plasma in an electron cyclotron resonance (ECR) plasma reactor and by (3) high energy oxygen ion irradiation. Thermally stimulated exo-electron emission (TSEE) spectroscopy was used to estimate the relative densities and energies of the surface states induced by the three different modes of introducing oxygen. Out of the two native defect levels found in GaAs by TSEE; at 325 K (0.7 eV below Ec) and at 415 K (0.9 below Ec); the former is seen to get broadened or split into multiple peaks in each of the methods. Multiple peaks in TSEE signify the presence of a closely spaced band of defect levels. Therefore the results exclusively point out that oxygen-related complexes contribute to the formation of a band of defects centered at 325 K in TSEE which is correlated to an energy level 0.7 eV below Ec known as the EL2 defect level. The results reported in this paper thus confirm that the TSEE peak at 0.7 eV below Ec is related to oxygen induced defects whereas the peak at 0.9 eV is not affected by the presence of oxygen-related species.

  16. Development of low noise preamplifier for the detection and position determination of single electrons in a Cerenkov Ring Imaging Detector by charge division

    International Nuclear Information System (INIS)

    Spencer, E.; Coyle, P.; Williams, D

    1987-10-01

    A preamplifier having 500 electrons noise (rms) has been developed for the detection and location of single electrons in a CRID detector at the SLD. A single channel contains preamp, RC-CR shaper, gain adjustment, driver, and calibration circuitry. Noise and linearity measurements are presented

  17. Detection and quantitative determination of heavy metals in electronic cigarette refill liquids using Total Reflection X-ray Fluorescence Spectrometry.

    Science.gov (United States)

    Kamilari, Eleni; Farsalinos, Konstantinos; Poulas, Konstantinos; Kontoyannis, Christos G; Orkoula, Malvina G

    2018-06-01

    Electronic cigarettes are considered healthier alternatives to conventional cigarettes containing tobacco. They produce vapor through heating of the refill liquids (e-liquids) which consist of propylene glycol, vegetable glycerin, nicotine (in various concentrations), water and flavoring agents. Heavy metals may enter the refill liquid during the production, posing a risk for consumer's health due to their toxicity. The objective of the present study was the development of a methodology for the detection and quantitative analysis of cadmium (Cd), lead (Pb), nickel (Ni), copper (Cu), arsenic (As) and chromium (Cr), employing Total Reflection X-Ray Fluorescence Spectroscopy (TXRF) as an alternative technique to ICP-MS or ICP-OES commonly used for this type of analysis. TXRF was chosen due to its advantages, which include short analysis time, promptness, simultaneous multi-element analysis capability and minimum sample preparation, low purchase and operational cost. The proposed methodology was applied to a large number of electronic cigarette liquids commercially available, as well as their constituents, in order to evaluate their safety. TXRF may be a valuable tool for probing heavy metals in electronic cigarette refill liquids to serve for the protection of human health. Copyright © 2018 Elsevier Ltd. All rights reserved.

  18. Sensorial analysis and electronic aroma detection to compare olive oils produced by different extraction methods

    Directory of Open Access Journals (Sweden)

    Vaz Freire, L. T.

    2011-12-01

    Full Text Available A sensorial analysis and an aroma analysis by electronic sensory devices were used to compare olive oils produced according to two different extraction methods. The extraction methods compared were the press system and two phase decanter. Samples were taken from the harvests of 2002-2004 and the olives were all from the same variety. The variety used was the Portuguese Galega sp. Olives were picked and technologically handled under predetermined and supervised conditions. Olive oils produced were better classified when the sensory analysis by a panel was applied than when an electronic sensory analysis was performed, even after sensor optimization. This observation is in accordance with the fact that olive oil has a low volatility matrix and “flavor”, rather than aroma, can give a clearer characterization than electronic sensory analysis alone, where aroma is the main characteristic evaluated.

    El análisis sensorial y el análisis de aromas por medio de sistemas sensoriales electrónicos han sido utilizado para comparar aceites de oliva producidos a través de dos sistemas de extracción diferentes. Los métodos de extracción comparados han sido el sistema de prensas y el decantador de dos fases. Las muestras fueron producidas durante las cosechas del periodo 2002- 2004, y las aceitunas eran todas de la misma variedad portuguesa Gallega sp. Las aceitunas fueron seleccionadas y tratadas tecnológicamente bajo condiciones predeterminadas y supervisadas. Los aceites producidos resultaron mejor clasificados cuando fue aplicado el análisis sensorial por panel que cuando se utilizó el análisis con detección electrónica de aromas, incluso después de la optimización de los sensores. Esta observación está de acuerdo con el hecho de que los aceites son una matriz poco volátil y que es el “flavour”, más que el aroma, el que junto con el gusto puede proporcionar una caracterización mejor que la detección electrónica, en

  19. Reproducibility of coronary calcification detection with electron-beam computed tomography

    International Nuclear Information System (INIS)

    Hernigou, A.; Challande, P.; Boudeville, J.C.; Sene, V.; Grataloup, C.; Plainfosse, M.

    1996-01-01

    If coronary calcification scores obtained with electron-beam computed tomography (EBT) were proved to be correlated to coronary atherosclerosis, the reproducibility of the technique had to be assessed before being useed for patient follow-up. A total of 150 patients, selected as a result of a cholesterol screening programme, were studied by EBT. Twelve contiguous 3-mm-thick transverse slices beginning on the proximal coronary arteries were obtained through the base of the heart. The amount of calcium was evaluated as the calcified area weighted by a coefficient depending on the density peak level. The value was expressed as a logarithmic scale. Intra-observer, inter-observer and inter-examination reproducibilities were calculated. They were 1.9, 1.3 and 7.2%, respectively. These results were good enough to allow the use of EBT for longitudinal studies. The influence of acquisition and calculation conditions on score computation were also analysed. (orig.)

  20. Detection of free radicals in γ-irradiated seasnail hard tissues by electron paramagnetic resonance

    International Nuclear Information System (INIS)

    Koeseoglu, Rahmi; Koeksal, Fevzi

    2003-01-01

    Gamma-irradiated seasnail (from family of Helix lukortium) hard tissues (CaCO 3 ) were investigated by electron paramagnetic resonance (EPR) at room temperature. The radicals produced by γ-irradiation in seasnail were attributed to orthorhombic C · O 2 - , freely rotating C · O 2 - , orthorhombic C · O 3 - , axial C · O 3 - , and axial C · O 3 3- free radicals. Unirradiated seasnail hard tissues also feature Mn 2+ ions in their EPR spectra. The hyperfine values were determined for the 13 C nucleus in the orthorhombic C · O 2 - and axial C · O 3 3- free radicals and for the manganese impurity ions. The g values of all the free radicals have been measured. The results were compared with the literature data for similar defects

  1. Detection of irradiated deboned turkey meat using electron spin resonance spectroscopy

    International Nuclear Information System (INIS)

    Gray, Richard; Stevenson, M.H.

    1989-01-01

    Bone fragments were extracted from two blocks of frozen deboned turkey meat (irradiated and non-irradiated) using alcoholic KOH digestion. Electron spin resonance (ESR) spectroscopy was used to differentiate between the samples. Comparison of an alcoholic KOH digestion procedure with a freeze drying and grinding method showed that the former method gave a signal which was 78% of that obtained using the freeze drying procedure. Regression analysis of the results obtained after subjection of the original non-irradiated sample to irradiation doses of 3.0, 5.0 and 7.0 kGy gave a linear relationship between irradiation dose and ESR signal strength over this range. Using this relationship the estimated mean dose received by the irradiated block was 4.72 kGy. (author)

  2. Detection of organic free radicals in irradiated pepper by electron spin resonance

    International Nuclear Information System (INIS)

    Ukai, Mitsuko; Shimoyama, Yuhei

    2002-01-01

    Using electron spin resonance (ESR) spectroscopy, we revealed various free radicals in a Japanese commercially available black pepper before and after γ-irradiation. The representative ESR spectrum of the pepper is composed of a sextet centered at g=2.0, a singlet at the same g-value and a singlet at g=4.0. The first one is attributable to a signal with hyperfine interactions of Mn 2+ ion (7.4 mT). The second one is due to an organic free radical. The third one may be originated from Fe 3+ ion of the non-hem Fe in proteins. A pair of signals appeared in the black pepper after γ-irradiation. The progressive saturation behavior reconfirmed the signal identification for the radicals in the black pepper. (author)

  3. Developing laser ablation in an electron cyclotron resonance ion source for actinide detection with AMS

    Energy Technology Data Exchange (ETDEWEB)

    Bauder, W. [Argonne National Laboratory, Physics Division, 9600 S. Cass Ave, Lemont, IL 60439 (United States); University of Notre Dame, Nuclear Science Laboratory, 124 Nieuwland Science Hall, Notre Dame, IN 46556 (United States); Pardo, R.C.; Kondev, F.G.; Kondrashev, S.; Nair, C.; Nusair, O. [Argonne National Laboratory, Physics Division, 9600 S. Cass Ave, Lemont, IL 60439 (United States); Palchan, T. [Hebrew University, Racah Institute of Physics, Jerusalem 91904 (Israel); Scott, R.; Seweryniak, D.; Vondrasek, R. [Argonne National Laboratory, Physics Division, 9600 S. Cass Ave, Lemont, IL 60439 (United States); Collon, P. [University of Notre Dame, Nuclear Science Laboratory, 124 Nieuwland Science Hall, Notre Dame, IN 46556 (United States); Paul, M. [Hebrew University, Racah Institute of Physics, Jerusalem 91904 (Israel)

    2015-10-15

    A laser ablation material injection system has been developed at the ATLAS electron cyclotron resonance (ECR) ion source for use in accelerator mass spectrometry experiments. Beam production with laser ablation initially suffered from instabilities due to fluctuations in laser energy and cratering on the sample surface by the laser. However, these instabilities were rectified by applying feedback correction for the laser energy and rastering the laser across the sample surface. An initial experiment successfully produced and accelerated low intensity actinide beams with up to 1000 counts per second. With continued development, laser ablation shows promise as an alternative material injection scheme for ECR ion sources and may help substantially reduce cross talk in the source.

  4. System for detecting neutrons in the harsh radiation environment of a relativistic electron beam

    International Nuclear Information System (INIS)

    Kruse, L.W.

    1978-06-01

    Newly developed detectors and procedures allow measurement of neutron yield and energy in the harsh radiation environment of a relativistic electron beam source. A new photomultiplier tube design and special gating methods provide the basis for novel time-of-flight and total-yield detectors. The technique of activation analysis is expanded to provide a neutron energy spectrometer. There is a demonstrated potential in the use of the integrated system as a valuable diagnostic tool to study particle-beam fusion, intense ion-beam interactions, and pulsed neutron sources for simulating weapons effects. A physical lower limit of 10 8 neutrons into 4π is established for accurate and meaningful measurements in the REB environment

  5. Scanning Electron Microscope Mapping System Developed for Detecting Surface Defects in Fatigue Specimens

    Science.gov (United States)

    Bonacuse, Peter J.; Kantzos, Peter T.

    2002-01-01

    An automated two-degree-of-freedom specimen positioning stage has been developed at the NASA Glenn Research Center to map and monitor defects in fatigue specimens. This system expedites the examination of the entire gauge section of fatigue specimens so that defects can be found using scanning electron microscopy (SEM). Translation and rotation stages are driven by microprocessor-based controllers that are, in turn, interfaced to a computer running custom-designed software. This system is currently being used to find and record the location of ceramic inclusions in powder metallurgy materials. The mapped inclusions are periodically examined during interrupted fatigue experiments. The number of cycles to initiate cracks from these inclusions and the rate of growth of initiated cracks can then be quantified. This information is necessary to quantify the effect of this type of defect on the durability of powder metallurgy materials. This system was developed with support of the Ultra Safe program.

  6. Detection of oxygen-related defects in GaAs by exo-electron emission spectroscopy

    International Nuclear Information System (INIS)

    Hulluvarad, Shiva S.; Naddaf, M.; Bhoraskar, S.V.

    2001-01-01

    The influence of intentional introduction of oxygen, at the surface of GaAs, on its native surface states was studied. Oxygen was made to interact with the surface of GaAs by three different means: (1) by growing native oxides, (2) exposing to oxygen plasma in an electron cyclotron resonance (ECR) plasma reactor and by (3) high energy oxygen ion irradiation. Thermally stimulated exo-electron emission (TSEE) spectroscopy was used to estimate the relative densities and energies of the surface states induced by the three different modes of introducing oxygen. Out of the two native defect levels found in GaAs by TSEE; at 325 K (0.7 eV below E c ) and at 415 K (0.9 below E c ); the former is seen to get broadened or split into multiple peaks in each of the methods. Multiple peaks in TSEE signify the presence of a closely spaced band of defect levels. Therefore the results exclusively point out that oxygen-related complexes contribute to the formation of a band of defects centered at 325 K in TSEE which is correlated to an energy level 0.7 eV below E c known as the EL2 defect level. The results reported in this paper thus confirm that the TSEE peak at 0.7 eV below E c is related to oxygen induced defects whereas the peak at 0.9 eV is not affected by the presence of oxygen-related species

  7. Detection of oxygen-related defects in GaAs by exo-electron emission spectroscopy

    International Nuclear Information System (INIS)

    Hulluvarad, Shiva S.; Naddaf, M.; Bhoraskar, S.V.

    2004-01-01

    The influence of intentional introduction of oxygen, at the surface of GaAs, on its native surface states was studied. Oxygen was made to interact with the surface of GaAs by three different means: (1) by growing native oxides, (2) exposing to oxygen plasma in an electron cyclotron resonance (ECR) plasma reactor and by (3) high energy oxygen ion irradiation. Thermally stimulated exo-electron emission (TSEE) spectroscopy was used to estimate the relative densities and energies of the surface states induced by the three different modes of introducing oxygen. Out of the two native defect levels found in GaAs by TSEE; at 325 K (0.7 eV below E c ) and at 415 K (0.9 below E c ); the former is seen to get broadened or split into multiple peaks in each of the methods. Multiple peaks in TSEE signify the presence of a closely spaced band of defect levels. Therefore the results exclusively point out that oxygen-related complexes contribute to the formation of a band of defects centered at 325 K in TSEE which is correlated to an energy level 0.7 eV below E c known as the EL2 defect level. The results reported in this paper thus confirm that the TSEE peak at 0.7 eV below E c is related to oxygen induced defects whereas the peak at 0.9 eV is not affected by the presence of oxygen-related species. (author)

  8. Detection of oxygen-related defects in GaAs by exo-electron emission spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Hulluvarad, Shiva S.; Naddaf, M.; Bhoraskar, S.V. E-mail: svb@physics.unipune.ernet.in

    2001-10-01

    The influence of intentional introduction of oxygen, at the surface of GaAs, on its native surface states was studied. Oxygen was made to interact with the surface of GaAs by three different means: (1) by growing native oxides, (2) exposing to oxygen plasma in an electron cyclotron resonance (ECR) plasma reactor and by (3) high energy oxygen ion irradiation. Thermally stimulated exo-electron emission (TSEE) spectroscopy was used to estimate the relative densities and energies of the surface states induced by the three different modes of introducing oxygen. Out of the two native defect levels found in GaAs by TSEE; at 325 K (0.7 eV below E{sub c}) and at 415 K (0.9 below E{sub c}); the former is seen to get broadened or split into multiple peaks in each of the methods. Multiple peaks in TSEE signify the presence of a closely spaced band of defect levels. Therefore the results exclusively point out that oxygen-related complexes contribute to the formation of a band of defects centered at 325 K in TSEE which is correlated to an energy level 0.7 eV below E{sub c} known as the EL2 defect level. The results reported in this paper thus confirm that the TSEE peak at 0.7 eV below E{sub c} is related to oxygen induced defects whereas the peak at 0.9 eV is not affected by the presence of oxygen-related species.

  9. Development of portable mass spectrometer with electron cyclotron resonance ion source for detection of chemical warfare agents in air.

    Science.gov (United States)

    Urabe, Tatsuya; Takahashi, Kazuya; Kitagawa, Michiko; Sato, Takafumi; Kondo, Tomohide; Enomoto, Shuichi; Kidera, Masanori; Seto, Yasuo

    2014-01-01

    A portable mass spectrometer with an electron cyclotron resonance ion source (miniECRIS-MS) was developed. It was used for in situ monitoring of trace amounts of chemical warfare agents (CWAs) in atmospheric air. Instrumental construction and parameters were optimized to realize a fast response, high sensitivity, and a small body size. Three types of CWAs, i.e., phosgene, mustard gas, and hydrogen cyanide were examined to check if the mass spectrometer was able to detect characteristic elements and atomic groups. From the results, it was found that CWAs were effectively ionized in the miniECRIS-MS, and their specific signals could be discerned over the background signals of air. In phosgene, the signals of the 35Cl+ and 37Cl+ ions were clearly observed with high dose-response relationships in the parts-per-billion level, which could lead to the quantitative on-site analysis of CWAs. A parts-per-million level of mustard gas, which was far lower than its lethal dosage (LCt50), was successfully detected with a high signal-stability of the plasma ion source. It was also found that the chemical forms of CWAs ionized in the plasma, i.e., monoatomic ions, fragment ions, and molecular ions, could be detected, thereby enabling the effective identification of the target CWAs. Despite the disadvantages associated with miniaturization, the overall performance (sensitivity and response time) of the miniECRIS-MS in detecting CWAs exceeded those of sector-type ECRIS-MS, showing its potential for on-site detection in the future. Copyright © 2013 Elsevier B.V. All rights reserved.

  10. The use of electron spin resonance spectroscopy for the detection of irradiated shellfish and spices

    International Nuclear Information System (INIS)

    Helle, N.; Linke, B.; Boegl, K.W.; Schreiber, G.A.

    1994-01-01

    A multilateral study on common shrimps, Norway lobster and paprika powder. The use of ESR spectroscopy in shellfish and some types of spice for the detection of previous irradiation is possible even on a routine basis. The radicals producing the specific ESR signals observed could at least in part be identified (CO 2 radicals in shellfish, cellulose radicals in paprica) and the overall rate of correct classifications was seen to be very high for this multicentre study. The multicentre study has further been able to prove that previous reservations about ESR as a method of detection are no longer justified. The authors hold that there is no reason in principle why ESR should not be on the list of officially recommended methods for the examination of shellfish and spices according to paragraph35 LMBG. Nevertheless, the two groups of food at issue here need to be investigated in more detail in a number of further research projects, some of which are mentioned in the following: -investigations on further species of shellfish so as to obtain a broad range of spectra for routine controls; - structural identification of radiation-specific radicals generated in addition to the CO 2 radical; - investigations into the influences of origin, time of fishing and stage of development on the ESR spectra of fishes; - examinations of further spices; - elucidation of links between cellulose contents and radical concentration. (orig./vhe) [de

  11. Carotid artery ultrasonographic assessment in patients from the Fremantle Diabetes Study Phase II with carotid bruits detected by electronic auscultation.

    Science.gov (United States)

    Knapp, Arthur; Cetrullo, Violetta; Sillars, Brett A; Lenzo, Nat; Davis, Wendy A; Davis, Timothy M E

    2014-09-01

    Electronic auscultation appears superior to acoustic auscultation for identifying hemodynamic abnormalities. The aim of this study was to determine whether carotid bruits detected by electronic stethoscope in patients with diabetes are associated with stenoses and increased carotid intima-medial thickness (CIMT). Fifty Fremantle Diabetes Study patients (mean±SD age, 73.7±10.0 years; 38.0% males) with a bruit found by electronic auscultation and 50 age- and sex-matched patients with normal carotid sounds were studied. The degree of stenosis and CIMT were assessed from duplex ultrasonography. Patients with a bruit were more likely to have stenosis of ≥50% and CIMT of >1.0 mm than those without (odds ratios [95% confidence intervals]=14.0 [1.8-106.5] and 5.3 [1.8-15.3], respectively; both P=0.001). For the six patients with stenosis of ≥70%, five had a bruit, and one (with a known total occlusion) did not (odds ratio=5.0 [0.6-42.8]; P=0.22). The sensitivity and specificity of carotid bruit for stenoses of ≥50% were 88% and 58%, respectively; respective values for stenoses of ≥70% were 83% and 52%. The equivalent negative predictive values were 96% and 98%, and positive predictive values were 30% and 10%, respectively. Electronic recording of carotid sounds for later interpretation is convenient and reliable. Most patients with stenoses had an overlying bruit. Most bruits were false positives, but ultrasonography is justified to document extent of disease; CIMT measurement will identify increased vascular risk in most of these patients. The absence of a bruit was rarely a false-negative finding, suggesting that these patients can usually be reassured that they do not have hemodynamically important stenosis.

  12. An ontology-based annotation of cardiac implantable electronic devices to detect therapy changes in a national registry.

    Science.gov (United States)

    Rosier, Arnaud; Mabo, Philippe; Chauvin, Michel; Burgun, Anita

    2015-05-01

    The patient population benefitting from cardiac implantable electronic devices (CIEDs) is increasing. This study introduces a device annotation method that supports the consistent description of the functional attributes of cardiac devices and evaluates how this method can detect device changes from a CIED registry. We designed the Cardiac Device Ontology, an ontology of CIEDs and device functions. We annotated 146 cardiac devices with this ontology and used it to detect therapy changes with respect to atrioventricular pacing, cardiac resynchronization therapy, and defibrillation capability in a French national registry of patients with implants (STIDEFIX). We then analyzed a set of 6905 device replacements from the STIDEFIX registry. Ontology-based identification of therapy changes (upgraded, downgraded, or similar) was accurate (6905 cases) and performed better than straightforward analysis of the registry codes (F-measure 1.00 versus 0.75 to 0.97). This study demonstrates the feasibility and effectiveness of ontology-based functional annotation of devices in the cardiac domain. Such annotation allowed a better description and in-depth analysis of STIDEFIX. This method was useful for the automatic detection of therapy changes and may be reused for analyzing data from other device registries.

  13. Support Vector Feature Selection for Early Detection of Anastomosis Leakage From Bag-of-Words in Electronic Health Records.

    Science.gov (United States)

    Soguero-Ruiz, Cristina; Hindberg, Kristian; Rojo-Alvarez, Jose Luis; Skrovseth, Stein Olav; Godtliebsen, Fred; Mortensen, Kim; Revhaug, Arthur; Lindsetmo, Rolv-Ole; Augestad, Knut Magne; Jenssen, Robert

    2016-09-01

    The free text in electronic health records (EHRs) conveys a huge amount of clinical information about health state and patient history. Despite a rapidly growing literature on the use of machine learning techniques for extracting this information, little effort has been invested toward feature selection and the features' corresponding medical interpretation. In this study, we focus on the task of early detection of anastomosis leakage (AL), a severe complication after elective surgery for colorectal cancer (CRC) surgery, using free text extracted from EHRs. We use a bag-of-words model to investigate the potential for feature selection strategies. The purpose is earlier detection of AL and prediction of AL with data generated in the EHR before the actual complication occur. Due to the high dimensionality of the data, we derive feature selection strategies using the robust support vector machine linear maximum margin classifier, by investigating: 1) a simple statistical criterion (leave-one-out-based test); 2) an intensive-computation statistical criterion (Bootstrap resampling); and 3) an advanced statistical criterion (kernel entropy). Results reveal a discriminatory power for early detection of complications after CRC (sensitivity 100%; specificity 72%). These results can be used to develop prediction models, based on EHR data, that can support surgeons and patients in the preoperative decision making phase.

  14. Electronic Cortisol Detection Using an Antibody-Embedded Polymer Coupled to a Field-Effect Transistor.

    Science.gov (United States)

    Jang, Hyun-June; Lee, Taein; Song, Jian; Russell, Luisa; Li, Hui; Dailey, Jennifer; Searson, Peter C; Katz, Howard E

    2018-05-16

    A field-effect transistor-based cortisol sensor was demonstrated in physiological conditions. An antibody-embedded polymer on the remote gate was proposed to overcome the Debye length issue (λ D ). The sensing membrane was made by linking poly(styrene- co-methacrylic acid) (PSMA) with anticortisol before coating the modified polymer on the remote gate. The embedded receptor in the polymer showed sensitivity from 10 fg/mL to 10 ng/mL for cortisol and a limit of detection (LOD) of 1 pg/mL in 1× PBS where λ D is 0.2 nm. A LOD of 1 ng/mL was shown in lightly buffered artificial sweat. Finally, a sandwich ELISA confirmed the antibody binding activity of antibody-embedded PSMA.

  15. Electronic Detection of Lectins Using Carbohydrate Functionalized Nanostructures: Graphene versus Carbon Nanotubes

    Science.gov (United States)

    Chen, Yanan; Vedala, Harindra; Kotchey, Gregg P.; Audfray, Aymeric; Cecioni, Samy; Imberty, Anne; Vidal, Sébastien; Star, Alexander

    2012-01-01

    Here we investigated the interactions between lectins and carbohydrates using field-effect transistor (FET) devices comprised of chemically converted graphene (CCG) and single-walled carbon nanotubes (SWNTs). Pyrene- and porphyrin-based glycoconjugates were functionalized noncovalently on the surface of CCG-FET and SWNT-FET devices, which were then treated with 2 µM of nonspecific and specific lectins. In particular, three different lectins (PA-IL, PA-IIL and ConA) and three carbohydrate epitopes (galactose, fucose and mannose) were tested. The responses of 36 different devices were compared and rationalized using computer-aided models of carbon nanostructure/glycoconjugate interactions. Glycoconjugates surface coverage in addition to one-dimensional structures of SWNTs resulted in optimal lectin detection. Additionally, lectin titration data of SWNT- and CCG-based biosensors were used to calculate lectin dissociation constants (Kd) and compare them to the values obtained from the isothermal titration microcalorimetry (ITC) technique. PMID:22136380

  16. Factors Affecting Detection Of Irradiated Bone Meat By Using Electron Spine Resonance

    International Nuclear Information System (INIS)

    FARAG, S.A.; ATIA, A.I.; HASSAN, G.M.

    2009-01-01

    Different types of bone meats were purchased locally such as camel, cow and sheep. The bones were removed, cleaned and irradiated with gamma rays at different doses (5, 10 and 20 kGy). The bone samples were stored in a refrigerator for five months for studying their stability of radiation-induced free radicals using electron spin resonance (ESR) technique. The effect of thermal treatment at 50 o C at intervals was studied besides effect of storage period and re-irradiation process on ESR signal intensity. The ESR spectrum for radical species in irradiated samples was characterized by signal with spectroscopic splitting factor (g factor) of g1=2.0025 and g2=1.9973 for camel, cow and sheep bones, respectively. The signal at g = 2.0025 was ascribed to free radical rotation CO -2 that was derived from radiation-induced hydroxyapatite. Generally, the results proved that all above mentioned factors under investigation can affect ESR signal intensity but not prevent the recognize of irradiated bones, therefore, it must be taken in mind when calculating the absorbed dose.

  17. Detection of Taste Change of Bovine and Goat Milk in Room Ambient Using Electronic Tongue

    Directory of Open Access Journals (Sweden)

    Imam Tazi

    2017-11-01

    Full Text Available An electronic tongue (e-tongue based on an array of lipid/polymer membranes has been successfully developed for measuring the taste evolution of natural milk. The e-tongue consisted of 16 different lipid/polymer membranes combined with or without a pH sensor. The natural milk of bovine and goat were purchased from the local farming store in Malang-Indonesia. The taste measurement was carried out, from fresh (0 h to stale (12 h, every two hours under room ambient without any treatment. The responses of the e-tongue were evaluated using a Principal Component Analysis (PCA and a Linear Discriminant Analysis (LDA. From PCA results, the taste of both milk samples tends to change by time although some groups show a partial overlapping. LDA results show the high precision of the e-tongue in clustering taste evolution. The correctly classified groups after the cross-validation procedure were achieved 95.7 and 87.1% for bovine and goat milk, respectively. The improvement of the classification using LDA was obtained by adding data from a pH sensor of each measurement as 100 and 98.6% for bovine and goat milk, respectively. This work indicates that the lab-made e-tongue may be useful to predict the quality of natural milk for the food industry.

  18. Free-living spirochetes from Cape Cod microbial mats detected by electron microscopy

    Science.gov (United States)

    Teal, T. H.; Chapman, M.; Guillemette, T.; Margulis, L.

    1996-01-01

    Spirochetes from microbial mats and anaerobic mud samples collected in salt marshes were studied by light microscopy, whole mount and thin section transmission electron microscopy. Enriched in cellobiose-rifampin medium, selective for Spirochaeta bajacaliforniensis, seven distinguishable spirochete morphotypes were observed. Their diameters ranged from 0.17 micron to > 0.45 micron. Six of these morphotypes came from southwest Cape Cod, Massachusetts: five from Microcoleus-dominated mat samples collected at Sippewissett salt marsh and one from anoxic mud collected at School Street salt marsh (on the east side of Eel Pond). The seventh morphotype was enriched from anoxic mud sampled from the north central Cape Cod, at the Sandy Neck salt marsh. Five of these morphotypes are similar or identical to previously described spirochetes (Leptospira, Spirochaeta halophila, Spirochaeta bajacaliforniensis, Spirosymplokos deltaeiberi and Treponema), whereas the other two have unique features that suggest they have not been previously described. One of the morphotypes resembles Spirosymplokos deltaeiberi (the largest free-living spirochete described), in its large variable diameter (0.4-3.0 microns), cytoplasmic granules, and spherical (round) bodies with composite structure. This resemblance permits its tentative identification as a Sippewissett strain of Spirosymplokos deltaeiberi. Microbial mats samples collected in sterile Petri dishes and stored dry for more than four years yielded many organisms upon rewetting, including small unidentified spirochetes in at least 4 out of 100 enrichments.

  19. Mechanism of Pseudogap Detected by Electronic Raman Scattering: Phase Fluctuation or Hidden Order?

    International Nuclear Information System (INIS)

    Hong-Yan, Lu; Yuan, Wan; Xiang-Mei, He; Qiang-Hua, Wang

    2009-01-01

    We study the electronic Raman scattering in the cuprates to distinguish the two possible scenarios of the pseudo-gap normal state. In one scenario, the pseudogap is assumed to be caused by phase fluctuations of the preformed Cooper pairs. We find that pair-breaking peaks appear in both the B 1g and B 2g Raman channels, and they are smeared and tend to shift to the same energy with the increasing strength of phase fluctuations. Thus both channels reflect the same pairing energy scale, irrespectively of the doping level. In another scenario, the pseudogap is assumed to be caused by a hidden order that competes with the superconducting order. As an example, we assume that the hidden order is the d-density-wave (DDW) order. We find analytically and numerically that in the DDW normal state there is no Raman peak in the B 2g channel in a tight-binding model up to the second nearest-neighbor hopping, while the Raman peak in the B 1g channel reflects the energy gap caused by the DDW order. This behavior is in agreement with experiments in the pseudogap normal state. To gain further insights, we also calculate the Raman spectra in the DDW+SC state. We study the doping and temperature dependence of the peak energy in both channels and find a two-gap behavior, which is in agreement with recent Raman experiments. Therefore, our results shed light on the hidden order scenario for the pseudogap

  20. Blinded Comparison between an In-Air Reverberation Method and an Electronic Probe Tester in the Detection of Ultrasound Probe Faults.

    Science.gov (United States)

    Dudley, Nicholas J; Woolley, Darren J

    2017-12-01

    The aim of this study was to perform a blinded trial, comparing the results of a visual inspection of the in-air reverberation pattern with the results of an electronic probe tester in detecting ultrasound probe faults. Sixty-two probes were tested. A total of 28 faults were found, 3 only by in-air reverberation assessment and 2 only by the electronic probe tester. The electronic probe tester provided additional information regarding the location of the fault in 74% of the cases in which both methods detected a fault. It is possible to detect the majority of probe faults by visual inspection and in-air reverberation assessment. The latter provides an excellent first-line test, easily performed on a daily basis by equipment users. An electronic probe tester is required if detailed evaluation of faults is necessary. Copyright © 2017 World Federation for Ultrasound in Medicine and Biology. All rights reserved.