WorldWideScience

Sample records for single-stage trickling filter

  1. Performance and optimisation of trickling filters on eel farms

    NARCIS (Netherlands)

    Kamstra, A.; Heul, van der J.W.; Nijhof, M.

    1998-01-01

    The design of trickling filters used on commercial eel farms differs considerably with respect to dimensions, hydraulic and substrate loads and filter medium applied. In this paper, a model, developed for ammonium removal in a pilot-scale trickling filter, has been validated for a range of

  2. The design of trickling biological periwinkle shells filter for closed ...

    African Journals Online (AJOL)

    ... water quality parameters such as DO, pH, temperature, BOD5, Seechi transparency, total alkalinity, free carbon dioxide, chloride, etc. in the treatment system were not significantly (p>0.05) different from that of the control system. We concluded that periwinkle shell is a suitable trickling filter medium for closed recirculation ...

  3. Anaerobic ammonium oxidation in the old trickling filters at Daspoort ...

    African Journals Online (AJOL)

    The century-old trickling filters at the Daspoort Wastewater Treatment Works in Pretoria (Gauteng, South Africa) are known for their remarkable removal of nitrogen from municipal wastewater. Our study was conducted to identify the microbiological processes responsible for this phenomenon and to establish whether ...

  4. Design and operation of nitrifying trickling filters in recirculating aquaculture: a review

    NARCIS (Netherlands)

    Eding, E.H.; Kamstra, A.; Verreth, J.A.J.; Huisman, E.A.; Klapwijk, A.

    2006-01-01

    This review deals with the main mechanisms and parameters affecting design and performance of trickling filters in aquaculture. Relationships between nitrification rates and easily accessible process parameters, like bulk phase concentration of TAN, O2, organic matter (COD), nitrite, temperature,

  5. Effect of organic nitrogen concentration on the efficiency of trickling filters

    Science.gov (United States)

    Kopeć, Łukasz; Drewnowski, Jakub; Fernandez-Morales, F. J.

    2018-02-01

    The study was conducted in Poland at six selected wastewater treatment plants (WWTP) based on the trickling filters Bioclere® technology. The aim of the study was to find the relationship between the influent organic nitrogen concentration and the purification efficiency expressed as effluent COD concentration. In the tests performed, the COD to BOD5 relationship was close to 2 and the ratio of BOD5 to TN was lower than 4. The research indicated that this specific chemical composition of raw wastewater causes appearance of filamentous bacteria on the surface of trickling filter filling and strongly affect the effluent quality.

  6. [Performance of cross flow trickling filter for H2S gas treatment].

    Science.gov (United States)

    Liu, Chun-Jing; Li, Jian; Liu, Jia; Peng, Shu-Jing; Li, Chao; Chen, Ying; He, Hong

    2012-09-01

    A grading cross bio-trickling filter was designed for H2S removal. Mixed microorganisms domesticated from the former experiment were immobilized to start up the trickling filter. Removal performances during starting up period and different loadings were investigated. Results showed that the immobilization of the trickling filter was completed within 3 d. The removal efficiency was higher than 99% when the inlet concentration was in the range of 110 mg x m(-3) to 230 mg x m(-3) (EBRT 30 s). At low inlet loadings, the front part of the trickling filter played a major role in H2S degradation, accounting for about 85%. Microbial diversity and population of the front part were superior to the tail one. At higher loadings, microbial diversity and population of the tail part increased significantly, from 4.5 x 10(7) cells x g (-1) to 5.17 x 10(8) cells x g(-1), and the elimination capacity was also improved,from 0.04 g x h(-1) to 0.67 g x h(-1). Rod-shaped bacteria were the dominant microorganisms on the surface of ceramics in the steady state as observed by SEM. The surfaces of ceramics were covered by a lot of microbial metabolites at high loadings. Analysis of the metabolites indicated that the majority of H2S was oxidized to sulfur and only a small portion was converted to sulfate.

  7. Kalman-filter model for determining block and trickle SNM losses

    International Nuclear Information System (INIS)

    Barlow, R.E.; Durst, M.J.; Smiriga, N.G.

    1982-07-01

    This paper describes an integrated decision procedure for deciding whether a diversion of SNM has occurred. Two possible types of diversion are considered: a block loss during a single time period and a cumulative trickle loss over several time periods. The methodology used is based on a compound Kalman filter model. Numerical examples illustrate our approach

  8. Biological treatment of wastewaters from a dye manufacturing company using a trickling filter.

    Science.gov (United States)

    Kornaros, M; Lyberatos, G

    2006-08-10

    The aim of this work was to assess the effectiveness of a biological trickling filter for the treatment of wastewaters produced by a company manufacturing organic dyes and varnishes. The combined wastewater effluent was fed to a pilot-scale trickling filter in two feeding modes, continuously and as a sequencing batch reactor (SBR). The biodegradability of the diluted wastewaters that were subjected to physicochemical treatment, using Ca(OH)(2) and FeSO(4), was initially studied using a continuously operated trickling filter. The system efficiency ranged up to 60-70% for a hydraulic loading of 1.1 m(3)/m(2)day and up to 80-85% for a hydraulic loading 0.6 m(3)/m(2)day. A stable chemical oxygen demand (COD) removal efficiency of 60-70% was achieved even in the case of undiluted wastewater at a hydraulic loading of 1.1 m(3)/m(2)day. The effectiveness of biological treatment of a mixture of the company's main wastewater streams was also examined. The microorganisms developed in the trickling filter were able to efficiently remove COD levels up to 36,000 mg/L, under aerobic conditions at pH values between 5.5 and 8.0. Depending on the operating conditions of the system, about 30-60% of the total COD removal was attributed to air stripping caused by the air supply at the bottom of the filter, whereas the rest of the COD was clearly removed through biological action. The proposed biological treatment process based on a trickling filter, which was operated either continuously or even better in an SBR mode, appears as a promising pretreatment step for coping with dye manufacturing wastewaters in terms of removing a significant portion of the organic content.

  9. Adopting primary plastic trickling filters as a solution for enhanced nitrification.

    Science.gov (United States)

    Wilson, Simon P; Ouki, Sabeha K; Saroj, Devendra P; Pearce, Pete A; Bancroft, Louise; Germain, Eve

    2015-01-01

    The wastewater industry is under pressure to optimize performance of sewage treatment works (STW), while simultaneously reducing energy consumption. Using a process configuration selection matrix, this paper explores the practicability of placing a hypothetical cross flow structured plastic media (CFSP) trickling filter (TF) immediately ahead of an existing conventional trickling filter process (CTFP), without intermediate clarification. The viability of this configuration is subsequently demonstrated using an empirical multispecies TF model. This predicts the enhanced nitrification performance of the CTFP by simulating prior removals of biochemical oxygen demand (BOD). The model predictions propose that prior 50-80% BOD removals can allow for further reductions in effluent ammoniacal nitrogen (NH4-N) concentrations of 40-70%, respectively. This illustrates that adopting low energy TF technologies can eliminate the requirement for more energy intensive alternatives, such as submerged aerated filters (SAF). Moreover, this configuration maximizes the potential of existing assets, while simultaneously improving nitrification robustness when compared with tertiary nitrification processes.

  10. APPLICATION OF TRICKLING FILTER FOR SEWAGE TREATMENT WITH HIGH AMMONIA NITRO GEN CONCENTRATION

    Directory of Open Access Journals (Sweden)

    Wojciech Dąbrowski

    2016-05-01

    Full Text Available The article presents the results of research about the possibility of using trickling filter for high ammonia concentration sewage treatment. The study was conducted with the use of reject water generated during anaerobic sewage sludge stabilization in dairy wastewater treatment plant (WWTP. They are usually returned to the beginning of WWTP. The value of BOD in reject water was approximately the same as in domestic and municipal sewage. Ammonia nitrogen concentration was varied from 145,0 to 390,0 mgN-NH4+/l and phosphorus from 16.0 to 38.0 mgP/l. The study used the Gunt test system CE701e, which allows controlling basic parameters of the treatment with trickling filter. Significant reduction of organic matter, total nitrogen and ammonium was observed during treatment. Average removal efficiency of ammonia nitrogen ranged from 73.6 to 80.3%. In the case of the Kjeldahl nitrogen removal efficiencies ranged from 74.4 to 79.8%. Because of the aerobic conditions during the treatment of phosphorus removal efficiency was low and varied from 32.0 to 33.7%. The research confirmed the efficiency of trickling filter for treatment sewage with high concentration of ammonia nitrogen.

  11. Nitrogen Removal in a Full-Scale Domestic Wastewater Treatment Plant with Activated Sludge and Trickling Filter

    Directory of Open Access Journals (Sweden)

    Davood Nourmohammadi

    2013-01-01

    Full Text Available During the last decade, more stringent effluent requirements concerning the nutrients effluent values have been imposed by legislation and social concern. In this study, efficiency of total nitrogen removal in activated sludge and trickling filter processes (AS/TF was investigated in Tehran North wastewater treatment plant. Biological system in this site was included, anoxic selector tank, aeration tank, final sedimentation, and trickling filter. A part of treated wastewater before chlorination was mixed with supernatant of dewatered sludge and fed to the trickling filter. Supernatant of dewatered sludge with high concentration of NH4-N was diluted by treated wastewater to provide complete nitrification in trickling filter Produced nitrate in trickling filter was arrived to the anoxic tank and converted to nitrogen gas by denitrification. According to the study result, low concentration of organic carbone and high concentration of NH4-N led to nitrification in TF, then nitrate denitrification to nitrogen gas occurred in selector area. NH4-N concentration decreased from 26.8 mg/L to 0.29 mg/L in TF, and NO3-N concentration increased from 8.8 mg/L to 27 mg/L in TF. Consequently, the total nitrogen decreased approximately to 50% in biological process. This efficiency has been observed in returned flow around 24% from final sedimentation into TF. It was concluded that, in comparison with biological nutrient removal processes, this process is very efficient and simple.

  12. Trickling filter for urea and bio-waste processing - dynamic modelling of nitrogen cycle

    Science.gov (United States)

    Zhukov, Anton; Hauslage, Jens; Tertilt, Gerin; Bornemann, Gerhild

    Mankind’s exploration of the solar system requires reliable Life Support Systems (LSS) enabling long duration manned space missions. In the absence of frequent resupply missions, closure of the LSS will play a very important role and its maximisation will to a large extent drive the selection of appropriate LSS architectures. One of the significant issues on the way to full closure is to effectively utilise biological wastes such as urine, inedible biomass etc. A very promising concept of biological waste reprocessing is the use of trickling filters which are currently being developed and investigated by DLR, Cologne, Germany. The concept is called Combined Regenerative Organic-Food Production (C.R.O.P.) and is based on the microbiological treatment of biological wastes and reprocessing them into aqueous fertilizer which can directly be used in a greenhouse for food production. Numerous experiments have been and are being conducted by DLR in order to fully understand and characterize the process. The human space exploration group of the Technical University of Munich (TUM) in cooperation with DLR has started to establish a dynamic model of the trickling filter system to be able to assess its performance on the LSS level. In the first development stage the model covers the nitrogen cycle enabling to simulate urine processing. This paper describes briefly the C.R.O.P. concept and the status of the trickling filter model development. The model is based on enzyme-catalyzed reaction kinetics for the fundamental microbiological reaction chain and is created in MATLAB. Verification and correlation of the developed model with experiment results has been performed. Several predictive studies for batch sequencing behavior have been performed, demonstrating a good capability of C.R.O.P. concept to be used in closed LSS. Achieved results are critically discussed and way forward is presented.

  13. Removal of enteroviruses from sewage by bench-scale rotary-tube trickling filters.

    Science.gov (United States)

    Clarke, N A; Chang, S L

    1975-08-01

    The efficacy of a rotary-tube type of trickling filter for removing coxsackievirus A9, poliovirus 1, and echovirus 12 suspended in raw settled sewage was investigated. At filtration rates equivalent to about 10 MGD (million gallons per day)/acre (ca. 3,785 m3/day per acre), the filters removed 95% of the poliovirus, 83% of echovirus 12, and 94% of coxsackievirus A9. Coliform, fecal streptococci, biochemical oxygen demand, and chemical oxygen demand removals were remarkably similar, averaging 94, 92, 93, and 95%, respectively. At filtration rates equivalent to about 23 MGD/acre, 59% of the poliovirus, 63% of the echovirus 23, and 81% of the coxsackievirus A9 were removed. Coliform, fecal streptococci, biochemical oxygen demand, and chemical oxygen demand removals at this filtration rate were 68, 75, 72, and 56%, respectively. Viruses were assumed to be adsorbed to the biological slime growing in the filters, but attempts to disassociate the viruses from the slime were unsuccessful, indicating that the slime-virus complex is very stable or that the viruses were somehow inactivated. The data indicate that coliform and fecal streptococci reductions in this type sewage treatment process can be used as an index of virus reduction. Disinfection, however, must be used to ensure a virus-free final effluent.

  14. Characterization and removal of specific organic constituents in an UASB-trickling-filter system treating domestic wastewater.

    Science.gov (United States)

    Pontes, Patrícia Procópio; Chernicharo, Carlos Augusto de Lemos

    2011-01-01

    This paper presents the characterization of specific organic constituents (carbohydrates, proteins and lipids) in raw sewage and in the anaerobic and aerobic effluents of a demo-scale (500 inhabitants) UASB- trickling-filter system. The evaluation of such parameters was carried out for two operating conditions, either without sludge recirculation (experiment I) from the trickling filter to the UASB reactor or with sludge recirculation (experiment II), for sludge thickening and stabilization, in the anaerobic reactor. The results showed that the contribution of acetic acid, carbohydrates, proteins and lipids amounted for approximately 70% of the total COD fed to the UASB during experiment I, whereas during experiment II these constituents amounted for only around 40% of the total COD. Although very high BOD and COD overall removal efficiencies were observed for the treatment system (around 90% and 80%, respectively), it was possible to infer that these efficiencies were mainly related to the removal of carbohydrates and lipids (around 80% removal), and of other non-identified constituents. The removal of proteins was much lower (around 50% removal), and the relative contribution of proteins to the total COD increased along the treatment course, being responsible for most of the residual COD of the treatment units. In the present system configuration, the UASB reactor played a major role in the removal of carbohydrates, whereas the trickling filter was very effective in the removal of lipids. The return of aerobic sludge for thickening and stabilization in the UASB reactor did not affect its performance.

  15. Potential of resource recovery in UASB/trickling filter systems treating domestic sewage in developing countries.

    Science.gov (United States)

    Bressani-Ribeiro, T; Brandt, E M F; Gutierrez, K G; Díaz, C A; Garcia, G B; Chernicharo, C A L

    2017-04-01

    This paper aims to present perspectives for energy (thermal and electric) and nutrient (N and S) recovery in domestic sewage treatment systems comprised of upflow anaerobic sludge blanket (UASB) reactors followed by sponge-bed trickling filters (SBTF) in developing countries. The resource recovery potential was characterized, taking into account 114 countries and a corresponding population of 968.9 million inhabitants living in the tropical world, which were grouped into three desired ranges in terms of cities' size. For each of these clusters, a technological arrangement flow-sheet was proposed, depending on their technical and economic viability from our best experience. Considering the population living in cities over 100, 000 inhabitants, the potential of energy and nutrient recovery via the sewage treatment scheme would be sufficient to generate electricity for approximately 3.2 million residents, as well as thermal energy for drying purposes that could result in a 24% volume reduction of sludge to be transported and disposed of in landfills. The results show that UASB/SBTF systems can play a very important role in the sanitation and environmental sector towards more sustainable sewage treatment plants.

  16. Performance of plastic- and sponge-based trickling filters treating effluents from an UASB reactor.

    Science.gov (United States)

    Almeida, P G S; Marcus, A K; Rittmann, B E; Chernicharo, C A L

    2013-01-01

    The paper compares the performance of two trickling filters (TFs) filled with plastic- or sponge-based packing media treating the effluent from an upflow anaerobic sludge blanket (UASB) reactor. The UASB reactor was operated with an organic loading rate (OLR) of 1.2 kgCOD m(-3) d(-1), and the OLR applied to the TFs was 0.30-0.65 kgCOD m(-3) d(-1) (COD: chemical oxygen demand). The sponge-based packing medium (Rotosponge) gave substantially better performance for ammonia, total-N, and organic matter removal. The superior TF-Rotosponge performance for NH(4)(+)-N removal (80-95%) can be attributed to its longer biomass and hydraulic retention times (SRT and HRT), as well as enhancements in oxygen mass transfer by dispersion and advection inside the sponges. Nitrogen removals were significant (15 mgN L(-1)) in TF-Rotosponge when the OLRs were close to 0.75 kgCOD m(-3) d(-1), due to denitrification that was related to solids hydrolysis in the sponge interstices. For biochemical oxygen demand removal, higher HRT and SRT were especially important because the UASB removed most of the readily biodegradable organic matter. The new configuration of the sponge-based packing medium called Rotosponge can enhance the feasibility of scaling-up the UASB/TF treatment, including when retrofitting is necessary.

  17. Determination of the hydraulic residence time of trickling filters using radiotracer experiments

    International Nuclear Information System (INIS)

    Debien, Bruno R.; Ferreira, Ladislau M.; Barreto, Alberto A.; Pinto, Amenonia M.F.

    2013-01-01

    Trickling filters (TF) are bioreactors fulfilled with inert materials working as support for biofilm development, and have been used in a large scale in wastewater treatment for organic matter, ammonia nitrogen and nitrate removal. TF's can be widely used in Brazil, especially because of its simplicity and operational low cost. The efficiency of pollutants removal processes depends on the water flow dynamics inside the reactor. For this reason, in the present work the mean residence time of two TF's containing different support materials were determined by means of tracer testes. The radioisotope 82Br - a gamma radiation emitter, produced from soluble potassium bromide irradiated in the TRIGA reactor at the Centre for the Development of Nuclear Energy (CDTN) - was used as a pseudo-conservative tracer for the comparative study of aqueous phase flow dynamics in both TF's. Mean residence time for the first TF (containing a single support material) was 0,3 hours, much smaller than the value obtained for the second TF (containing two alternated support materials), around 2 hours. These results were already expected, once the alternated material is denser than the single one, and are very important for numerical modeling studies aiming to determine the kinetic constant for removal of the pollutants cited above. (author)

  18. Determination of the hydraulic residence time of trickling filters using radiotracer experiments

    Energy Technology Data Exchange (ETDEWEB)

    Debien, Bruno R.; Ferreira, Ladislau M.; Barreto, Alberto A.; Pinto, Amenonia M.F., E-mail: brunordebien@gmail.com [Universidade Federal de Minas Gerais (UFMG), Minas Gerais, MG (Brazil). Dept. de Geografia. Lab. de Geomorfologia; Moreira, Rubens M., E-mail: aab@cdtn.br, E-mail: amfp@cdtn.br, E-mail: rubens@cdtn.br [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2013-07-01

    Trickling filters (TF) are bioreactors fulfilled with inert materials working as support for biofilm development, and have been used in a large scale in wastewater treatment for organic matter, ammonia nitrogen and nitrate removal. TF's can be widely used in Brazil, especially because of its simplicity and operational low cost. The efficiency of pollutants removal processes depends on the water flow dynamics inside the reactor. For this reason, in the present work the mean residence time of two TF's containing different support materials were determined by means of tracer testes. The radioisotope 82Br - a gamma radiation emitter, produced from soluble potassium bromide irradiated in the TRIGA reactor at the Centre for the Development of Nuclear Energy (CDTN) - was used as a pseudo-conservative tracer for the comparative study of aqueous phase flow dynamics in both TF's. Mean residence time for the first TF (containing a single support material) was 0,3 hours, much smaller than the value obtained for the second TF (containing two alternated support materials), around 2 hours. These results were already expected, once the alternated material is denser than the single one, and are very important for numerical modeling studies aiming to determine the kinetic constant for removal of the pollutants cited above. (author)

  19. A pilot scale trickling filter with pebble gravel as media and its performance to remove chemical oxygen demand from synthetic brewery wastewater.

    Science.gov (United States)

    Habte Lemji, Haimanot; Eckstädt, Hartmut

    2013-10-01

    Evaluating the performance of a biotrickling filter for the treatment of wastewaters produced by a company manufacturing beer was the aim of this study. A pilot scale trickling filter filled with gravel was used as the experimental biofilter. Pilot scale plant experiments were made to evaluate the performance of the trickling filter aerobic and anaerobic biofilm systems for removal of chemical oxygen demand (COD) and nutrients from synthetic brewery wastewater. Performance evaluation data of the trickling filter were generated under different experimental conditions. The trickling filter had an average efficiency of (86.81±6.95)% as the hydraulic loading rate increased from 4.0 to 6.4 m(3)/(m(2)∙d). Various COD concentrations were used to adjust organic loading rates from 1.5 to 4.5 kg COD/(m(3)∙d). An average COD removal efficiency of (85.10±6.40)% was achieved in all wastewater concentrations at a hydraulic loading of 6.4 m(3)/(m(2)∙d). The results lead to a design organic load of 1.5 kg COD/(m(3)∙d) to reach an effluent COD in the range of 50-120 mg/L. As can be concluded from the results of this study, organic substances in brewery wastewater can be handled in a cost-effective and environmentally friendly manner using the gravel-filled trickling filter.

  20. Effect of application rates and media types on nitrogen and surfactant removal in trickling filters applied to the post-treatment of effluents from UASB reactors

    Energy Technology Data Exchange (ETDEWEB)

    Almeida, P. G. S. de; Taveres, F. v. F.; Chernicharo, C. A. I.

    2009-07-01

    Tricking filters are a very promising alternative for the post treatment of effluents from UASB reactors treating domestic sewage,especially in developing countries. Although a fair amount of information is already available regarding organic mater removal in this combined system, very little is known in relation to nitrogen and surfactant removal in trickling filters post-UASB reactors. Therefore, the purpose of this study was to evaluate and compare the effect evaluate and compare the effect of different application rates and packing media types on trickling filters applied to the post-treatment of effluents from UASB reactors, regarding the removal of ammonia nitrogen and surfactants. (Author)

  1. Effect of application rates and media types on nitrogen and surfactant removal in trickling filters applied to the post-treatment of effluents from UASB reactors

    International Nuclear Information System (INIS)

    Almeida, P. G. S. de; Taveres, F. v. F.; Chernicharo, C. A. I.

    2009-01-01

    Tricking filters are a very promising alternative for the post treatment of effluents from UASB reactors treating domestic sewage,especially in developing countries. Although a fair amount of information is already available regarding organic mater removal in this combined system, very little is known in relation to nitrogen and surfactant removal in trickling filters post-UASB reactors. Therefore, the purpose of this study was to evaluate and compare the effect evaluate and compare the effect of different application rates and packing media types on trickling filters applied to the post-treatment of effluents from UASB reactors, regarding the removal of ammonia nitrogen and surfactants. (Author)

  2. Treating landfill leachate using passive aeration trickling filters; effects of leachate characteristics and temperature on rates and process dynamics.

    Science.gov (United States)

    Matthews, Richard; Winson, Michael; Scullion, John

    2009-04-01

    Biological ammoniacal-nitrogen (NH(4)(+)-N) and organic carbon (TOC) treatment was investigated in replicated mesoscale attached microbial film trickling filters, treating strong and weak strength landfill leachates in batch mode at temperatures of 3, 10, 15 and 30 degrees C. Comparing leachates, rates of NH(4)(+)-N reduction (0.126-0.159 g m(-2) d(-1)) were predominantly unaffected by leachate characteristics; there were significant differences in TOC rates (0.072-0.194 g m(-2) d(-1)) but no trend relating to leachate strength. Rates of total oxidised nitrogen (TON) accumulation (0.012-0.144 g m(-2) d(-1)) were slower for strong leachates. Comparing temperatures, treatment rates varied between 0.029-0.319 g NH(4)(+)-N m(-2) d(-1) and 0.033-0.251 g C m(-2) d(-1) generally increasing with rising temperatures; rates at 3 degrees C were 9 and 13% of those at 30 degrees C for NH(4)(+)-N and TOC respectively. For the weak leachates (NH(4)(+)-N<140 mg l(-1)) complete oxidation of NH(4)(+)-N was achieved. For the strong leachates (NH(4)(+)-N 883-1150 mg l(-1)) a biphasic treatment response resulted in NH(4)(+)-N removal efficiencies of between 68 and 88% and for one leachate no direct transformation of NH(4)(+)-N to TON in bulk leachate. The temporal decoupling of NH(4)(+)-N oxidation and TON accumulation in this leachate could not be fully explained by denitrification, volatilisation or anammox, suggesting temporary storage of N within the treatment system. This study demonstrates that passive aeration trickling filters can treat well-buffered high NH(4)(+)-N strength landfill leachates under a range of temperatures and that leachate strength has no effect on initial NH(4)(+)-N treatment rates. Whether this approach is a practicable option depends on a range of site specific factors.

  3. C.R.O.P. - Combined Regenerative Organic food Production: Using trickling filters for wet composting of organic waste in hydroponic greenhouse cultures

    OpenAIRE

    Hauslage, Jens; Bornemann, Gerhild; Winzer, Felix; Waßer, Kai; Kraska, Thorsten; Hemmersbach, Ruth; Anken, Ralf Hendrik

    2014-01-01

    In the past decades the upcoming shortage of mineral oil caused intense public debates and research efforts on the subject of alternative fuels and the recycling of plastics. The limited availability of environmentally compatible fertilizer for food production purposes attracted muss less public interest, but is of equal importance. C.R.O.P. is a sustainable concept for the improvement of organic wastes and wastewaters, which combines microbial trickling filters for waste processing with hydr...

  4. Detection of Legionella-contaminated aerosols in the vicinity of a bio-trickling filter of a breeding sow facility - A pilot study.

    Science.gov (United States)

    Walser, Sandra M; Brenner, Bernhard; Wunderlich, Anika; Tuschak, Christian; Huber, Stefanie; Kolb, Stefanie; Niessner, Reinhard; Seidel, Michael; Höller, Christiane; Herr, Caroline E W

    2017-01-01

    The urbanization of agricultural areas results in a reduction of distances between residential buildings and livestock farms. In the public debate, livestock farming is increasingly criticized due to environmental disturbance and odor nuisance originating from such facilities. One method to reduce odor and ammonia is by exhaust air treatment, for example, by biological exhaust air purification processes with bio-trickling filters filled with tap water. Higher temperatures in the summer time and the generation of biofilms are ideal growth conditions for Legionella. However, there are no studies on the presence of Legionella in the water of bio-trickling filters and the release of Legionella-containing aerosols. Therefore, the aim of this study was to investigate Legionella in wash water and emitted bioaerosols of a bio-trickling filter system of a breeding sow facility. For this purpose, measurements were carried out using a cyclone sampler. In addition, samples of wash water were taken. Legionella were not found by culture methods. However, using molecular biological methods, Legionella spp. could be detected in wash water as well as in bioaerosol samples. With antibody-based methods, Legionella pneumophila were identified. Further studies are needed to investigate the environmental health relevance of Legionella-containing aerosols emitted by such exhaust air purification systems. Copyright © 2016 Elsevier B.V. All rights reserved.

  5. Bacterial community involved in the nitrogen cycle in a down-flow sponge-based trickling filter treating UASB effluent.

    Science.gov (United States)

    Mac Conell, E F A; Almeida, P G S; Martins, K E L; Araújo, J C; Chernicharo, C A L

    2015-01-01

    The bacterial community composition of a down-flow sponge-based trickling filter treating upflow anaerobic sludge blanket (UASB) effluent was investigated by pyrosequencing. Bacterial community composition considerably changed along the reactor and over the operational period. The dominant phyla detected were Proteobacteria, Verrucomicrobia, and Planctomycetes. The abundance of denitrifiers decreased from the top to the bottom and it was consistent with the organic matter concentration gradients. At lower loadings (organic and nitrogen loading rates), the abundance of anammox bacteria was higher than that of the ammonium-oxidizing bacteria in the upper portion of the reactor, suggesting that aerobic and anaerobic ammonium oxidation occurred. Nitrification occurred in all the compartments, while anammox bacteria prominently appeared even in the presence of high organic carbon to ammonia ratios (around 1.0-2.0 gCOD gN(-1)). The results suggest that denitrifiers, nitrifiers, and anammox bacteria coexisted in the reactor; thus, different metabolic pathways were involved in ammonium removal in the post-UASB reactor sponge-based.

  6. Eukaryotic Community Shift in Response to Organic Loading Rate of an Aerobic Trickling Filter (Down-Flow Hanging Sponge Reactor) Treating Domestic Sewage.

    Science.gov (United States)

    Miyaoka, Yuma; Hatamoto, Masashi; Yamaguchi, Takashi; Syutsubo, Kazuaki

    2017-05-01

    In this study, changes in eukaryotic community structure and water quality were investigated in an aerobic trickling filter (down-flow hanging sponge, DHS) treating domestic sewage under different organic loading rates (OLRs). The OLR clearly influenced both sponge pore water quality and relative flagellates and ciliates (free-swimming, carnivorous, crawling, and stalked protozoa) abundances in the retained sludge. Immediately after the OLR was increased from 1.05 to 1.97 kg chemical oxygen demand (COD) m -3  day -1 , COD and NH 4 + -N treatment efficiencies both deteriorated, and relative flagellates and ciliates abundances then increased from 2-8 % to 51-65 % total cells in the middle-bottom part of the DHS reactor. In a continuous operation at a stable OLR (2.01 kg COD m -3  day -1 ), effluent water quality improved, and relative flagellates and ciliates abundances decreased to 15-46 % total cells in the middle-bottom part of the DHS reactor. This result may indicate that flagellates and ciliates preferentially graze on dispersed bacteria, thus, stabilizing effluent water quality. Additionally, to investigate eukaryotic community structure, clone libraries based on the 18S ribosomal ribonucleic acid (rRNA) gene of the retained sludge were constructed. The predominant group was Nucletmycea phylotypes, representing approximately 29-56 % total clones. Furthermore, a large proportion of the clones had sewage.

  7. Full scale application of the autotrophic denitrification in trickling filters for treatment of rejection water with high ammonia concentrations from sludge dewatering. Final report; Untersuchungen zur autotrophen Stickstoffentfernung aus ammoniumreichem Filtratwasser der Schlammentwaesserung mit grosstechnischer Realisierung in Tropfkoerpern. Abschlussbericht

    Energy Technology Data Exchange (ETDEWEB)

    Neumueller, B.; Metzger, J.W.; Pinnekamp, J.

    2003-07-01

    At many municipal wastewater treatment plants a considerable fraction of nitrogen is recirculated from the anaerobic sludge dewatering. This amounts up to 20% of the total influent nitrogen load of the wastewater treatment plant. The separate treatment of this sludge liquor creates new capacities for the treatment plant and improves effluent quality. A new process for treatment of this sludge liquor with ammonium-nitrogen concentrations above 600 mg/l is the autotrophic denitrification after partial nitritation. At the University of Stuttgart the first semi-technical trickling filter plant was built by which autotrophic denitrification was achieved. At the wastewater treatment plant of Sindelfingen the first full-scale implementation of the autotrophic denitrification in trickling filters has been designed and built. In a first trickling filter 60% of ammonia is transformed to nitrite. The investigations showed, that a few mg/l of free ammonia in this trickling filter were sufficient to inhibit the nitratation but not the nitritation. To achieve this, operating conditions as pH and temperature are of great importance. The concentration of free ammonia should be kept constant because there is an adaption of the microorganisms to free ammonia. After a decrease of the free ammonia concentration the inhibition of the nitratation declines. By thermally killing the biomass and restarting the process, can guarantee a total inhibition of the nitratation, while the concentration of free ammonia is low. In the second, closed trickling filter (anoxic conditions) ammonium is converted autotrophically to nitrogen with nitrite as electron acceptor. It was possible to set up the anoxic ammonium oxidation in full scale without inoculating the process. The very slow growth of the anammox-bacteria leads to a long adaptation phase of the process. All operating conditions such as anoxic conditions, high temperature and a concentration of nitrite below 70 mg/l have to be observed

  8. Efeito da qualidade da água na perda de carga em filtros utilizados na irrigação localizada Effect of water quality on head loss in filters utilized in trickle irrigation

    Directory of Open Access Journals (Sweden)

    Túlio A. P. Ribeiro

    2005-03-01

    Full Text Available O presente trabalho teve como objetivo apresentar a investigação experimental de uma fonte hídrica superficial utilizada em um sistema de irrigação por gotejamento e sua influência na evolução da perda de carga de dois filtros, um de disco e outro de manta sintética não-tecida, na filtragem da água. Analisou-se a variação temporal dos principais parâmetros físicos, químicos e biológicos da água de irrigação que causam problemas de entupimento nos emissores. Os critérios para avaliação das impurezas presentes na água de irrigação basearam-se em estudos realizados nos sistemas de irrigação localizada. A pesquisa foi desenvolvida em quatro etapas de 30 dias, em diferentes estações do ano. Os resultados mostraram que os parâmetros químicos que apresentaram médio risco de obstrução aos emissores, foram: pH, ferro e sulfetos. Os parâmetros físicos e biológicos analisados apresentaram baixo risco de entupimento dos emissores. Fez-se o acompanhamento da evolução da perda de carga em função do volume filtrado, objetivando uma análise comparativa. No filtro de manta sintética não-tecida a evolução da perda de carga foi mais acentuada e mais rápida em relação à de disco.This study had the objective to conduct an experimental enquiry on a surface water source utilized in a trickle irrigation system and its influence on the head loss evolution in two filters - a disc filter (130 micra and a non-woven synthetic fabric in filtration of water. The temporal variation of physical, chemical and biological parameters of the irrigation water causing problem of obstruction in drippers were analysed. The evaluation criterion of the impurities present in the irrigation water were based on the studies of the trickle irrigation systems. The research was executed in four phases of 30 days each, in different seasons. The results showed that the chemical factors, which presented medium risk of clogging for emitters, were p

  9. Tratamento de águas residuárias de suinocultura em reator UASB e filtro anaeróbio em série seguidos de filtro biológico percolador Treatment of swine wastewater in UASB reactor and anaerobic filter in series followed of trickling filter

    Directory of Open Access Journals (Sweden)

    Rose Maria Duda

    2011-03-01

    Full Text Available Avaliou-se o desempenho de um reator anaeróbio de fluxo ascendente com manta de lodo (UASB seguido de um filtro anaeróbio, instalados em série, com volume total de 300 L e 190 L, respectivamente, no tratamento de águas residuárias de suinocultura. As cargas orgânicas volumétricas aplicadas no reator UASB foram de 12,4;15,5; 23,2 e 26,3 g DQOtotal (L d-1. Para o pós-tratamento do efluente do sistema anaeróbio em dois estágios utilizou-se um filtro biológico percolador com volume total de 250 L. O meio suporte utilizado nos filtros anaeróbio e biológico percolador foi composto por anéis de bambu. No sistema de tratamento anaeróbio e de pós-tratamento foram observadas eficiências médias de remoção de demanda química de oxigênio total (DQOtotal, sólidos suspensos totais (SST, nitrogênio total (NT, fósforo total (P-total, Cu e Zn de até 98, 99, 78, 84, 99 e 98%, respectivamente.The performance of an upflow anaerobic sludge blanket (UASB followed by the anaerobic filter, installed in series, was evaluated for the treatment of swine wastewater. The total volume of UASB and anaerobic filter were of 300 L and 190 L, respectively. The organic load rate applied on the reactor UASB were of 12.4, 15.5, 23.2 and 26.3 g total COD (L d-1. For the post-treatment of effluent the anaerobic system was used a trickling filter with total volume of 250 L. The supports used in the anaerobic filter and trickling filter were composed by bamboo rings. The efficiencies of removal the chemical oxygen demand, total solids suspended, nitrogen, total phosphorus, Cu and Zn were of up to 98, 99, 78, 84, 99 and 98%, respectively, for the anaerobic and aerobic treatment system.

  10. Delayed Single Stage Perineal Posterior Urethroplasty

    International Nuclear Information System (INIS)

    Ali, S.; Shahnawaz; Shahzad, I.; Baloch, M. U.

    2015-01-01

    Objective: To determine the delayed single stage perineal posterior urethroplasty for treatment of posterior urethral stricture/distraction defect. Study Design: Descriptive case series. Place and Duration of Study: Department of Urology, Jinnah Postgraduate Medical Centre, Karachi, from January 2009 to December 2011. Methodology: Patients were selected for delayed single stage perineal posterior urethroplasty for treatment of posterior urethral stricture / distraction defect. All were initially suprapubically catheterized followed by definitive surgery after at least 3 months. Results: Thirty male patients were analyzed with a mean follow-up of 10 months, 2 patients were excluded as they developed failure in first 3 months postoperatively. Mean patients age was 26.25 ± 7.9 years. On follow-up, 7 patients (23.3 percentage) experienced recurrent stricture during first 10 months. Five (16.6 percentage) patients were treated successfully with single direct visual internal urethrotomy. Two patients (6.6 percentage) had more than one direct visual internal urethrotomy and considered failed. Re-do perineal urethroplasty was eventually performed. The overall success rate was 93.3 percentage with permissive criteria allowing single direct visual internal urethrotomy and 76.6% with strict criteria allowing no more procedures postoperatively. Conclusion: Posterior anastomotic urethroplasty offers excellent long-term results to patients with posterior urethral trauma and distraction defect even after multiple prior procedures. (author)

  11. Styrene biofiltration in a trickle-bed reactor

    Directory of Open Access Journals (Sweden)

    V. Novak

    2008-04-01

    Full Text Available The biological treatment of styrene waste gas in a trickle-bed filter (TBF was investigated. The bioreactor consisted of a two-part glass cylinder (ID 150 mm filled with 25 mm polypropylene Pall rings serving as packing material. The bed height was 1m. Although the laboratory temperature was maintained at 22 ºC, the water temperature in the trickle-bed filter was slightly lower (about 18 ºC.The main aim of our study was to observe the effect of empty-bed residence time (EBRT on bioreactor performance at a constant pollutant concentration over an extended time period. The bioreactor was inoculated with a mixed microbial consortium isolated from a styrene-degrading biofilter that had been running for the previous two years. After three weeks of acclimation period, the bioreactor was loaded with styrene (100 mg.m-3. EBRT was in the range of 53 s to 13 s. A maximum elimination capacity (EC of 11.3 gC.m-3.h-1 was reached at an organic loading (OL rate of 18.6 gC.m-3.h-1.

  12. Biofiltration of Chloroform in a Trickle Bed Air Biofilter Under ...

    Science.gov (United States)

    In this paper, the application of biofiltration is investigated for controlled removal of gas phase chloroform through cometabolic degradation with ethanol. A trickle bed air biofilter (TBAB) operated under acidic pH 4 is subjected to aerobic biodegradation of chloroform and ethanol. The TBAB is composed of pelleted diatomaceous earth filter media inoculated with filamentous fungi species, which served as the principle biodegrading microorganism. The removal efficiencies of 5 ppmv of chloroform mixed with different ratios of ethanol as cometabolite (25, 50, 100, 150, and 200 ppmv) ranged between 69.9 and 80.9%. The removal efficiency, reaction rate kinetics, and the elimination capacity increased proportionately with an increase in the cometabolite concentration. The carbon recovery from the TBAB amounted to 69.6% of the total carbon input. It is postulated that the remaining carbon contributed to excess biomass yield within the system. Biomass control strategies such as starvation and stagnation were employed at different phases of the experiment. The chloroform removal kinetics provided a maximum reaction rate constant of 0.0018 s−1. The highest ratio of chemical oxygen demand (COD)removal/nitrogenutilization was observed at 14.5. This study provides significant evidence that the biodegradation of a highly chlorinated methane can be favored by cometabolism in a fungi-based TBAB. Chloroform is volatile hazardous chemical emitted from publicly owned treatment

  13. Single-stage MPPT control realization for Aalborg inverter in photovoltaic system

    DEFF Research Database (Denmark)

    Zhang, Shuai; Wu, Weimin; Wang, Houqing

    2017-01-01

    In this paper, the single-stage Maximum Power Point Tracking (MPPT) control strategy for the Aalborg photovoltaic inverter is presented. Aalborg inverter has many advantages, such as high efficiency, wide range of input voltage, minimum voltage drop of the filtering inductors, etc. Nevertheless......, it is essentially a “half-bridge” inverter with two input sources, where one source works in MPPT mode, the other is out of control. If without the reasonable parameter design and the proper control, the bus-voltage of this inverter may change greatly, resulting in the serious power oscillation around maximum power...... that the proposed control strategy has good steady-state and dynamic performances....

  14. Design, Construction and Measured Performance of a Single-Stage ...

    African Journals Online (AJOL)

    The design philosophy, construction and measured performances of a single stage, single entry centrifugal pump demonstration unit are presented. In the construction, close-coupled induction motor drives the centrifugal pump, which draws fluid (water) from a water storage tank and delivers same through a flow control ...

  15. Single-stage repair versus traditional repair of high anorectal ...

    African Journals Online (AJOL)

    random number table. The patients in group A were treated with a single-stage operation, whereas the patients in group B were treated with a standard staged operation. (either PSARP or abdominoperineal pull-through). After clinical evaluation using the Kelly score, patients were divided into three clinical groups ...

  16. Control of Single-Stage Single-Phase PV inverter

    DEFF Research Database (Denmark)

    Ciobotaru, Mihai; Teodorescu, Remus; Blaabjerg, Frede

    2005-01-01

    In this paper the issue of control strategies for single-stage photovoltaic (PV) inverter is addressed. Two different current controllers have been implemented and an experimental comparison between them has been made. A complete control structure for the single-phase PV system is also presented...

  17. Water Quality of Trickling Biological Periwinkle Shells Filter for ...

    African Journals Online (AJOL)

    The designed biofilter and other system components were constructed, assembled and commissioned for pilot catfish production. The system with the designed biofilter served as the treatment system, while that without biofilter served as the control system. Data were collected daily (except for BOD5) on water quality ...

  18. Biological drinking water treatment of anaerobic groundwater in trickling filters

    NARCIS (Netherlands)

    De Vet, W.W.J.M.

    2011-01-01

    Drinking water production from anaerobic groundwater is usually achieved by so called conventional techniques such as aeration and sand filtration. The notion conventional implies a long history and general acceptation of the application, but doesn’t necessarily mean a thorough understanding of the

  19. Estimation of nitrification capacity of rock media trickling filters in ...

    African Journals Online (AJOL)

    In this investigation an average apparent nitrification capacity of approximately 1.25 to 1.29 gN per m2 of media surface area per day [gN/(ms2·d)] ammonia removal was determined for 2 existing rock media TFs retrofitted as NTFs in the prototype ENBNRAS system. (nominal surface area of 45 ms2/m3 for the rock media).

  20. Upgrading Army Sewage Treatment Plant Trickling Filters with Synthetic Media.

    Science.gov (United States)

    1984-08-01

    for separate disposal. Grit chamber overflow will normally pass through two sewage shredders or will be bypassed through two 3- ft, manually raked bar...rakes. Hydraulic capacity per construction spes sewage shredders 2 x 7.0 m&d - 14.0 mad at peak -14 mid Grit chamber Hydraulic capacity based on I fps at...7 1/2 hp each) for the lagoon system, and one sludge drainage system for the lagoon. The total cost was $440,000 in 1975. However, no breakdown of the

  1. Estimation of nitrification capacity of rock media trickling filters in ...

    African Journals Online (AJOL)

    To address this deficiency, a full-scale ENBNRAS prototype was implemented at the Daspoort Wastewater Treatment Works (DWWTW) in Tshwane, South Africa. In this investigation an average apparent nitrification capacity of approximately 1.25 to 1.29 gN per m2 of media surface area per day [gN/(ms2Ed)] ammonia ...

  2. Operação de filtros biológicos percoladores pós-reatores UASB sem a etapa de decantação secundária Operation of trickling filters post-UASB reactors without the secondary sedimentation stage

    Directory of Open Access Journals (Sweden)

    Paulo Gustavo Sertório de Almeida

    2011-09-01

    Full Text Available A pesquisa teve por objetivo avaliar filtros biológicos percoladores (FBP pós-reatores UASB operando sem a etapa de decantação secundária, em termos da remoção da demanda bioquímica e química de oxigênio (DBO e DQO e sólidos suspensos totais (SST. O aparato experimental consistia em um reator UASB que alimentava quatro FBP em paralelo, preenchidos com diferentes materiais suporte. O reator UASB operou em regime hidráulico permanente, e três condições operacionais foram impostas aos FBP durante o período experimental. Em geral, os sistemas UASB/FBP foram capazes de promover o atendimento aos padrões de lançamento. Em condições de baixas cargas orgânicas volumétricas (COV, o uso de materiais de enchimento de maior área superficial específica não proporcionou ganhos expressivos em termos de desempenho. Contudo, o uso de meio suporte baseado em espumas de poliuretano propiciou melhoria significativa na qualidade do efluente final. O uso de sistemas UASB/FBP sem decantadores secundários parece ser uma promissora alternativa para a simplificação operacional da tecnologia, e uma importante estratégia para o tratamento de efluentes domésticos em países em desenvolvimento. No entanto, o sucesso do emprego desta tecnologia fica condicionado ao correto gerenciamento do lodo anaeróbio do reator UASB, a fim de que sejam evitadas sobrecargas nos FBP.The research aimed at evaluating the operation of trickling filters (TF post-UASB reactors without the secondary sedimentation stage, in terms of biochemical and chemical oxygen demand (BOD and COD and total suspended solids (TSS removal. The experimental apparatus consisted of one UASB reactor followed by four TF in parallel, each one filled with a different packing media. The UASB reactor was operated at a permanent hydraulic regime, while three operational conditions were imposed to the TF during the experimental period. In general, the UASB/TF systems were able to comply with

  3. evaluation of bamboo porous pipe as line source emitter in trickle ...

    African Journals Online (AJOL)

    CHRISTY

    This paper attempts to evaluate the use of bamboo as porous pipe (line source) emitter in trickle ... KEY WORDS: Trickle irrigation, Bamboo, emitter, Porous-pipe. INTRODUCTION. Trickle irrigation system also known as drip irrigation is one of the examples of localized ... period of time to maintain part of the soil at or.

  4. Single-stage accelerator mass spectrometer radiocarbon-interference identification and positive-ionisation characterisation

    Energy Technology Data Exchange (ETDEWEB)

    Wilcken, K.M., E-mail: klaus.wilcken@ansto.gov.au [Scottish Universities Environmental Research Centre, Scottish Enterprise Technology Park, East Kilbride G75 0QF (United Kingdom); Freeman, S.P.H.T.; Xu, S.; Dougans, A. [Scottish Universities Environmental Research Centre, Scottish Enterprise Technology Park, East Kilbride G75 0QF (United Kingdom)

    2013-01-15

    A single-stage accelerator mass spectrometer (SSAMS) is a good alternative to conventional spectrometers based on tandem electrostatic acceleration for radiocarbon measurement and permits experimentation with both negative and positive carbon ions. However, such {sup 14}C AMS of either polarity ions is limited by an interference. In the case of anion acceleration we have newly determined this to be summed {sup 13}C and {sup 16}O by improvising an additional Wien filter on our SSAMS deck. Also, {sup 14}C AMS might be improved by removing its dependency on negative-ionisation in a sputter ion source. This requires negative-ionisation of sample atoms elsewhere to suppress the {sup 14}N interference, which we accomplish by transmitting initially positive ions through a thin membrane. The ionisation dependence on ion-energy is found to be consistent with previous experimentation with vapours and thicker foils.

  5. Control of Single-Stage Single-Phase PV inverter

    DEFF Research Database (Denmark)

    Ciobotaru, Mihai; Teodorescu, Remus; Blaabjerg, Frede

    2005-01-01

    In this paper the issue of control strategies for single-stage photovoltaic (PV) inverter is addressed. Two different current controllers have been implemented and an experimental comparison between them has been made. A complete control structure for the single-phase PV system is also presented......-forward; - and the grid current controller implemented in two different ways, using the classical proportional integral (PI) and the novel proportional resonant (PR) controllers. The control strategy was tested experimentally on 1.5 kW PV inverter........ The main elements of the PV control structure are: - a maximum power point tracker (MPPT) algorithm using the incremental conductance method; - a synchronization method using the phase-locked-loop (PLL), based on delay; - the input power control using the dc voltage controller and power feed...

  6. New results for single stage low energy carbon AMS

    International Nuclear Information System (INIS)

    Klody, G.M.; Schroeder, J.B.; Norton, G.A.; Loger, R.L.; Kitchen, R.L.; Sundquist, M.L.

    2005-01-01

    A new configuration of the NEC single stage, low energy carbon AMS system (U.S. Patent 6,815,666 B2) has been built and tested. The injector includes two 40-sample ion sources, electrostatic and magnetic analysis, and fast sequential injection. The gas stripper, analyzing magnet, electrostatic analyzer, and detector are on an open air 250 kV deck. Both 12 C and 13 C currents are measured on the deck after the stripper, and an SSB detector is used for 14 C counting. Injected 12 C and mass 13 ( 13 C and 12 CH) currents are also measured. Automated controls follow a user-specified run list for unattended operation. Initial test results show precision for 14 C/ 12 C ratios of better than 5 per mil, and backgrounds for unprocessed graphite of less than 0.005 x modern. We will report final results for precision, background, and throughput and discuss related design features

  7. Gas-solid trickle flow hydrodynamics in a packed column

    NARCIS (Netherlands)

    Westerterp, K.R.; Kuczynski, M.

    1987-01-01

    The pressure gradient and the static and the dynamic hold-up have been measured for a system consisting of a Fluid Cracking Catalyst (FCC) of 30–150 × 10−6 m diameter, trickling over a packed bed and with a gas streaming in countercurrent flow. The experiments were carried out at ambient conditions

  8. Trickle Bed Reactor Operation under Forced Liquid Feed Rate Modulation

    Czech Academy of Sciences Publication Activity Database

    Hanika, Jiří; Jiřičný, Vladimír; Karnetová, P.; Kolena, J.; Lederer, J.; Skála, D.; Staněk, Vladimír; Tukač, V.

    2007-01-01

    Roč. 13, č. 4 (2007), s. 192-198 ISSN 1451-9372 R&D Projects: GA MPO(CZ) FT-TA/039 Institutional research plan: CEZ:AV0Z40720504 Keywords : trickle-bed reactor * period * feed rate Subject RIV: CI - Industrial Chemistry, Chemical Engineering

  9. Thymol Hydrogenation in Bench Scale Trickle Bed Reactor

    Czech Academy of Sciences Publication Activity Database

    Dudas, J.; Hanika, Jiří; Lepuru, J.; Barkhuysen, M.

    2005-01-01

    Roč. 19, č. 3 (2005), s. 255-262 ISSN 0352-9568 Institutional research plan: CEZ:AV0Z40720504 Keywords : thymol hydrogenation * trickle bed reactor * gas-liquid-solid reaction Subject RIV: CI - Industrial Chemistry, Chemical Engineering Impact factor: 0.632, year: 2005

  10. Philosophy of Education as an accidental trickle | Mwaniki | Journal ...

    African Journals Online (AJOL)

    Philosophy of Education as an accidental trickle. ... Journal of Language, Technology & Entrepreneurship in Africa ... and employing an anecdotic, hypothetical quasi scenario-building methodology to visit learning and teaching of philosophy of education and the career-building in the field at our universities, it attempts, ...

  11. NASA Glenn's Single-Stage Axial Compressor Facility Upgraded

    Science.gov (United States)

    Brokopp, Richard A.

    2004-01-01

    NASA Glenn Research Center's Single-Stage Axial Compressor Facility was upgraded in fiscal year 2003 to expand and improve its research capabilities for testing high-speed fans and compressors. The old 3000-hp drive motor and gearbox were removed and replaced with a refurbished 7000-hp drive motor and gearbox, with a maximum output speed of 21,240 rpm. The higher horsepower rating permits testing of fans and compressors with higher pressure ratio or higher flow. A new inline torquemeter was installed to provide an alternate measurement of fan and compressor efficiency, along with the standard pressure and temperature measurements. A refurbished compressor bearing housing was also installed with bidirectional rotation capability, so that a variety of existing hardware could be tested. Four new lubrication modules with backup capability were installed for the motor, gearbox, torquemeter, and compressor bearing housing, so that in case the primary pump fails, the backup will prevent damage to the rotating hardware. The combustion air supply line for the facility inlet air system was activated to provide dry air for repeatable inlet conditions. New flow conditioning hardware was installed in the facility inlet plenum tank, which greatly reduced the inlet turbulence. The new inlet can also be easily modified to accommodate 20- or 22-in.-diameter fans and compressors, so a variety of existing hardware from other facilities (such as Glenn's 9- by 15-Foot Low-Speed Wind Tunnel) can be tested in the Single-Stage Axial Compressor Facility. An exhaust line was also installed to provide bleed capability to remove the inlet boundary layer. To improve the operation and control of the facility, a new programmable logic controller (PLC) was installed to upgrade from hardwired relay logic to software logic. The PLC also enabled the usage of human-machine interface software to allow for easier operation of the facility and easier reconfiguration of the facility controls when

  12. Single-stage mass spectrometric analyses of resin bead samples

    Energy Technology Data Exchange (ETDEWEB)

    Smith, D. H.; Walker, R. L.; Bertram, L. K.; Carter, J. A.

    1978-10-01

    Plutonium and uranium from dissolver solutions loaded on resin beads can be analyzed on single-stage mass spectrometers with little or no degradation of results provided proper care is exercised with regard to sample handling techniques. Additionally, storage of samples on resin beads is feasible for periods at least as long as six months provided the beads are not exposed to residual HNO/sub 3/ and air; it is probable that beads will retain their integrity much longer than six months when stored under collodion, but as yet no data to support this contention have been collected. Conventional or commercial mass spectrometers can readily be adapted to the resin bead technique by installing a pulse-counting detection system. The cost of such conversion will vary depending on whether or not a data acquisition system will be needed. A reasonable estimate is that the cost will be in the neighborhood of $15,000; this figure includes the price of a multi-channel analyzer to serve as a temporary data storage device, but does not include the cost of a computer. It does not appear that it will be practicable to switch easily back and forth between pulse-counting and current integration modes unless the instrument is provided with a movable Faraday cup. Using the same multiplier in both modes would undoubtedly degrade its performance in each. The requirements of low background counting rates and high gain for pulse counting, and of relatively high signal handling capacity in current integration are mutually incompatible if demanded of the same multiplier.

  13. Single Stage Contactor Testing Of The Next Generation Solvent Blend

    Energy Technology Data Exchange (ETDEWEB)

    Herman, D. T.; Peters, T. B.; Duignan, M. R.; Williams, M. R.; Poirier, M. R.; Brass, E. A.; Garrison, A. G.; Ketusky, E. T.

    2014-01-06

    The Modular Caustic Side Solvent Extraction (CSSX) Unit (MCU) facility at the Savannah River Site (SRS) is actively pursuing the transition from the current BOBCalixC6 based solvent to the Next Generation Solvent (NGS)-MCU solvent to increase the cesium decontamination factor. To support this integration of NGS into the MCU facility the Savannah River National Laboratory (SRNL) performed testing of a blend of the NGS (MaxCalix based solvent) with the current solvent (BOBCalixC6 based solvent) for the removal of cesium (Cs) from the liquid salt waste stream. This testing utilized a blend of BOBCalixC6 based solvent and the NGS with the new extractant, MaxCalix, as well as a new suppressor, tris(3,7dimethyloctyl) guanidine. Single stage tests were conducted using the full size V-05 and V-10 liquid-to-liquid centrifugal contactors installed at SRNL. These tests were designed to determine the mass transfer and hydraulic characteristics with the NGS solvent blended with the projected heel of the BOBCalixC6 based solvent that will exist in MCU at time of transition. The test program evaluated the amount of organic carryover and the droplet size of the organic carryover phases using several analytical methods. The results indicate that hydraulically, the NGS solvent performed hydraulically similar to the current solvent which was expected. For the organic carryover 93% of the solvent is predicted to be recovered from the stripping operation and 96% from the extraction operation. As for the mass transfer, the NGS solvent significantly improved the cesium DF by at least an order of magnitude when extrapolating the One-stage results to actual Seven-stage extraction operation with a stage efficiency of 95%.

  14. Hydrodynamic Studies on a Trickle Bed Reactor for Foaming Liquids

    Directory of Open Access Journals (Sweden)

    Renu Gupta

    2010-10-01

    Full Text Available Hydrodynamic studies of trickle bed reactors (TBRs are essential for the design and prediction of their performance. The hydrodynamic characteristics involving pressure drop and dynamic liquid saturation are greatly affected by the physical properties of the liquids. In the present study experiments have been carried out in a concurrent downflow air - liquid trickle bed reactor to investigate the dynamic liquid saturation and pressure drop for the water (non-foaming and 3% polyethylene glycol and 4% polyethylene glycol foaming liquids in the gas continuous regime (GCF and foaming pulsing regime (FP. In the GCF regime the dynamic liquid saturation was found to increase with increase in liquid flow rate for non-foaming and foaming liquids. While for 3% and 4% polyethylene glycol solutions the severe foaming was observed in the high interaction regime and the regime is referred to as foaming pulsing (FP regime. The decrease in dynamic liquid saturation followed by a sharp rise in the pressure drop was observed during transition from gas GCF to FP regime. However in the FP regime, a dip in the dynamic liquid saturation was observed. The pressure drop for foaming liquids is observed to be manifolds higher compared to non-foaming liquid in the GCF regime. ©2010 BCREC UNDIP. All rights reserved(Received: 16th January 2010, Revised: 10th February 2010, Accepted: 21st Feberuary 2010[How to Cite: R. Gupta, A. Bansal. (2010. Hydrodynamic Studies on a Trickle Bed Reactor for Foaming Liquids. Bulletin of Chemical Reaction Engineering & Catalysis, 5 (1: 31-37. doi:10.9767/bcrec.5.1.7127.31-37][How to Link / DOI: http://dx.doi.org/10.9767/bcrec.5.1.7127.31-37 || or local:  http://ejournal.undip.ac.id/index.php/bcrec/article/view/7127][Cited by: Scopus 1 | ] 

  15. Hydrodynamic Studies on a Trickle Bed Reactor for Foaming Liquids

    Directory of Open Access Journals (Sweden)

    Ajay Bansal

    2010-10-01

    Full Text Available Hydrodynamic studies of trickle bed reactors (TBRs are essential for the design and prediction of their performance. The hydrodynamic characteristics involving pressure drop and dynamic liquid saturation are greatly affected by the physical properties of the liquids. In the present study experiments have been carried out in a concurrent downflow air - liquid trickle bed reactor to investigate the dynamic liquid saturation and pressure drop for the water (non-foaming and 3% polyethylene glycol and 4% polyethylene glycol foaming liquids in the gas continuous regime (GCF and foaming pulsing regime (FP. In the GCF regime the dynamic liquid saturation was found to increase with increase in liquid flow rate for non-foaming and foaming liquids. While for 3% and 4% polyethylene glycol solutions the severe foaming was observed in the high interaction regime and the regime is referred to as foaming pulsing (FP regime. The decrease in dynamic liquid saturation followed by a sharp rise in the pressure drop was observed during transition from gas GCF to FP regime. However in the FP regime, a dip in the dynamic liquid saturation was observed. The pressure drop for foaming liquids is observed to be manifolds higher compared to non-foaming liquid in the GCF regime. ©2010 BCREC UNDIP. All rights reserved(Received: 16th January 2010, Revised: 10th February 2010, Accepted: 21st Feberuary 2010[How to Cite: R. Gupta, A. Bansal. (2010. Hydrodynamic Studies on a Trickle Bed Reactor for Foaming Liquids. Bulletin of Chemical Reaction Engineering & Catalysis, 5 (1: 31-37. doi:10.9767/bcrec.5.1.775.31-37][How to Link / DOI: http://dx.doi.org/10.9767/bcrec.5.1.775.31-37 ][Cited by: Scopus 1 |

  16. Use of skin stretchers for single-stage bilateral mastectomies in a dog and a cat.

    Science.gov (United States)

    Miyazaki, Yuta; Aikawa, Takeshi; Shimatsu, Taichi; Nishimura, Masaaki; Sadahiro, Shigeo

    2018-04-01

    To describe the application of skin stretchers for closure of single-stage bilateral mastectomies in a dog and a cat. Clinical case report. A 12-year-old intact female Miniature Dachshund and a 13-year-old spayed female domestic short-hair cat. Skin stretchers were applied to the site of the skin adjacent to mammary glands for 2-4 days before surgery. Cable tension was adjusted every 6-8 hours to elongate the skin and to achieve primary closure of single-stage bilateral mastectomy without tension. Wound closure after single-stage bilateral mastectomy was achieved without tension or major complication in both animals. Use of skin stretchers allows primary closure of single-stage bilateral mastectomy in dogs and cats. © 2017 The American College of Veterinary Surgeons.

  17. Single-Stage, Gelled Hydrazine System for Mars Ascent Vehicle Propulsion, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Microcosm, Inc. in cooperation with Aerojet Rocketdyne is presenting an innovative approach to the Mars Ascent Vehicle (MAV). The single-stage monopropellant system...

  18. Single Stage Transthoracic Approach to the Right Lung and Liver Dome Hydatid Cysts

    Directory of Open Access Journals (Sweden)

    Rasih Yazkan

    2011-09-01

    lung, the hepatic lesions were all of the dome located. Conclusions :Single stage transthoracic approach is prevent the second surgical procedures on simultaneous right lung and liver dome hydatid cyst and it is safe and effective method.

  19. NOFBX Single-Stage-to-Orbit Mars Ascent Vehicle Engine, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — We propose the continuation of our research and development of a Nitrous Oxide Fuel Blend (NOFBXTM) Single-Stage-to-Orbit (SSTO) monopropellant propulsion system for...

  20. Single Stage Knee Arthroplasty Revision Surgery: A Systematic Review of the Literature.

    Science.gov (United States)

    Chew, E; Khan, W S; Agarwal, S; Morgan-Jones, R

    2015-01-01

    Total Knee Arthroplasty is an increasingly common procedure and revision surgery, particularly for infection, is associated with significant morbidity and healthcare costs. The current gold standard is a two stage revision procedure but single stage revision is increasingly being used in some departments to improve patient outcomes. We conducted a systematic review of the literature to determine the up-to-date evidence underlying the use of a single stage knee approach in revision surgery. A total of 12 studies were included in this review amounting to 433 revision surgeries. This is the largest review of single stage knee revision surgery. The procedures described were heterogenous and included the 'two-in-one' technique as well as other single stage revision procedures. There were also differences in implants and antibiotic regimens. The mean re-infection rates described in 10 studies was 9.4% (range 0-19.2%) after a mean follow-up of 40.3 months (range 7-180 months). The re-infection rates in the studies published over the last 30 years are falling, and this is not accounted for by any significant change in duration of follow-up during this period. The outcome scores varied, but patients generally showed an improvement. The Knee Society Score and the Oxford Knee Score were the most commonly used in five and three studies respectively. We conclude that the current evidence for single stage revision is variable and there is a lack of good quality evidence to address whether single stage revisions is thorough enough to eradicate deep infection and is able to restore adequate function. There is a need for larger prospective studies with standardised procedures and protocol, and with adequate follow-up. Till then, patients considered for a single stage approach should be thoroughly assessed and the surgery should be performed by a senior surgeon with experience in single stage knee revisions.

  1. Single-stage revision for periprosthetic hip infection using antibiotic loaded impaction graft.

    Science.gov (United States)

    Ebied, Ayman M; Elseedy, Adel I; Gamal, Osama

    2016-11-10

    Staged revision for periprosthetic infection of the hip is an accepted and widely used technique by many surgeons. However, single-stage exchange of the hip prosthesis remains an attractive option to others because of the advantages of reduced morbidity, shorter treatment time and hospital stay in addition to the reduced cost of treatment. Single-stage revision for periprosthetic hip infection can achieve excellent results if a specific protocol for patients' selection and management is followed. 52 patients with evidence of periprosthetic infection had preoperative aspiration of the affected hip. The infecting organisms were identified in 33/52 and single-stage revision was performed. The remaining 19 patients had a 2-stage exchange arthroplasty. Patients in the single-stage revision protocol had antibiotic loaded morsellized bone graft, a cemented cup and a long cementless stem. At an average follow up of 6 (range 4-8) years postoperatively, only 1 case of persistent infection was found in the single-stage group - a 97% rate of eradicating infection was achieved. Single-stage exchange achieves excellent success rate in patients with periprosthetic infection when a specific protocol for patient selection and management is followed.

  2. Rational use of water in trickle irrigation design.

    Science.gov (United States)

    Saad, J. C. C.; da Silva Junior, H. M.

    2012-04-01

    In trickle irrigation systems, the design is based on the pre-established emission uniformity (EU) which is the combined result of the equipment characteristics and its hydraulic configuration. However, this desired value of the EU may not be confirmed by the final project (in field conditions) and neither by the yield uniformity. However, the most important is to assure yield uniformity with rational use of water. The hypotheses of this research were: a) the EU of a trickle irrigation system at field conditions is equal to the emission uniformity pre-established in the design; b) EU has always the lowest value when compared with other indicators of uniformity; c) the discharge variation coefficient is not equal to production variation coefficient in the operational unit; d) the productivity variation coefficient is more dependent on water depth applied than the EU. This study aimed to evaluate the relationships among EU used in the irrigation system design, water depth applied and the final yield uniformity. The uniformity indicators evaluated were: EU, distribution uniformity (UD) and the index proposed by Barragan & Wu (2005). They were compared estimating the performance of a trickle irrigation system applied in a citrus orchard with dimensions of 400m x 600m. The design of the irrigation system was optimized by a Linear Programming model. The tree rows were leveled in the larger direction and the spacing adopted in the orchard was 7m x 4m. The manifold line was always operating on a slope condition. The sensitivity analysis involved different slopes, 0, 3, 6, 9 and 12%, and different values of emission uniformity, 60, 70, 75, 80, 85, 90 and 94%. The citrus yield uniformity was evaluated by the variation coefficient. The emission uniformity (EU) after design differed from the EU pre-established, more sharply in the initial values lower than 90%. Comparing the uniformity indexes, the EU always generated lower values when compared with the UD and with the index

  3. Single-Stage Revision Arthroplasty for Infection-An Underutilized Treatment Strategy.

    Science.gov (United States)

    Negus, Jonathan J; Gifford, Peter B; Haddad, Fares S

    2017-07-01

    The burden of revision arthroplasty surgery for infection is rising as the rate of primary arthroplasty surgery increases. Infected arthroplasty rates are now relatively low, but the sheer increase in volume is leading to considerable patient morbidity and significant increases in costs to the health care system. Single-stage revision for infection is one of the several accepted treatment options, but the indications and results are debated. This review aims to clarify the current evidence. MEDLINE/PubMed databases were reviewed for studies that looked at single- or one-stage revision knee or hip arthroplasty for infection. There is increasing evidence that single-stage revision for infection can control infection and with decreased morbidity, mortality, and health care costs compared with a staged approach. However, the indications are still debated. Recently, there has been a determined effort to define an infected arthroplasty in a manner that will allow for standardization of reporting in the literature. The evidence supporting single stage for knee arthroplasty is catching up with the result with hip arthroplasty. High-quality data from randomized controlled trials are now pending. After the gradual evolution of using the single-stage approach, with the widespread acceptance of this definition, we can now standardize comparisons across the world and move toward a refined definition of the ideal patient population for single-stage arthroplasty revision in both the hip and the knee population. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. Numerical Simulation of single-stage axial fan operation under dusty flow conditions

    Science.gov (United States)

    Minkov, L. L.; Pikushchak, E. V.

    2017-11-01

    Assessment of the aerodynamic efficiency of the single-stage axial flow fan under dusty flow conditions based on a numerical simulation using the computational package Ansys-Fluent is proposed. The influence of dust volume fraction on the dependences of the air volume flow rate and the pressure drop on the rotational speed of rotor is demonstrated. Matching functions for formulas describing a pressure drop and volume flow rate in dependence on the rotor speed and dust content are obtained by numerical simulation for the single-stage axial fan. It is shown that the aerodynamic efficiency of the single-stage axial flow fan decreases exponentially with increasing volume content of dust in the air.

  5. Design considerations for single-stage and two-stage pneumatic pellet injectors

    International Nuclear Information System (INIS)

    Gouge, M.J.; Combs, S.K.; Fisher, P.W.; Milora, S.L.

    1988-09-01

    Performance of single-stage pneumatic pellet injectors is compared with several models for one-dimensional, compressible fluid flow. Agreement is quite good for models that reflect actual breech chamber geometry and incorporate nonideal effects such as gas friction. Several methods of improving the performance of single-stage pneumatic pellet injectors in the near term are outlined. The design and performance of two-stage pneumatic pellet injectors are discussed, and initial data from the two-stage pneumatic pellet injector test facility at Oak Ridge National Laboratory are presented. Finally, a concept for a repeating two-stage pneumatic pellet injector is described. 27 refs., 8 figs., 3 tabs

  6. imulation Results of Single Stage AC- AC Converter for Induction Heating

    Directory of Open Access Journals (Sweden)

    S. ARUMUGAM

    2010-12-01

    Full Text Available This paper presents simulation of single stage Induction heating system with series Load Resonance. Low frequency AC is converted in to High Frequency Ac using newly developed ZVS-PWM high frequency inverter. This High Frequency is used for Induction Heating .Single stage AC-AC converter system is modeled and simulated using Matlab Simulink. The simulation results of ZVS-PWM high frequency system are presented. The effectiveness of this UFAC-to-HFAC direct power frequency converter using IGBTs for consumer high-frequency IH appliances is evaluated and proved on the basis of simulation results.

  7. Analysis of U and Pu resin bead samples with a single stage mass spectrometer

    International Nuclear Information System (INIS)

    Smith, D.H.; Walker, R.L.; Bertram, L.K.; Carter, J.A.

    1979-01-01

    Resin bead sampling enables the shipment of nanogram U and Pu quantities for analysis. Application of this sampling technique to safeguards was investigated with a single-stage mass spectrometer. Standards gave results in good agreement with NBS certified values. External precisions of +-0.5% were obtained on isotopic ratios of approx. 0.01; precisions on quantitative measurements are +-1.0%

  8. Practical Considerations Concerning the Interleaved Transition Mode Single-stage Ballast

    DEFF Research Database (Denmark)

    Teodorescu, Remus; Kjær, Søren Bækhøj; Munk-Nielsen, Stig

    2002-01-01

    The aim of this paper is to present a novel single-stage interleaved ballast focusing on practical design aspects like: key current expression, overall losses, harmonic analysis of the differential-mode EMI current and preheating ballast function. A new preheating method is also presented. A PSPI...

  9. Single-Stage Low-Power Quadrature RF Receiver Front-End: The LMV Cell

    DEFF Research Database (Denmark)

    Liscidini, Antonio; Mazzanti, Andrea; Tonietto, Riccardo

    2006-01-01

    This paper presents the first quadrature RF receiver front-end where, in a single stage, low-noise amplifier (LNA), mixer and voltage-controlled oscillator (VCO) share the same bias current. The new structure exploits the intrinsic mixing functionality of a classical LC-tank oscillator providing ...

  10. Single stage buck-boost DC-AC neutral point clamped inverter

    DEFF Research Database (Denmark)

    Mo, Wei; Loh, Poh Chiang; Andrew, A.

    2012-01-01

    This paper proposes a new single stage buck-boost DC-AC neutral point clamped inverter topology which integrates the cascaded configurations of recently introduced inductor-capacitor-capacitor-transformer impedance source network (by Adamowicz) and classic NPC configuration. As a consequence...

  11. Comparison between a two-stage and single-stage digesters when ...

    African Journals Online (AJOL)

    Phenol is a pollutant found in many industrial wastewaters, which diminishes biogas formation in anaerobic digesters. In this study, a two-stage (acidogenic and methanogenic) anaerobic digester (TSAD) was compared to a single stage digester (SSD), in treating a synthetic wastewater contaminated with phenol.

  12. Treatment of domestic sewage at low temperatuer in a two-anaerobic step system followed by a tricklig filter

    NARCIS (Netherlands)

    Elmitwally, T.A.; Lier, van J.B.; Zeeman, G.; Lettinga, G.

    2003-01-01

    The treatment of domestic sewage at low temperature was studied in a two-anaerobic-step system followed by an aerobic step, consisting of an anaerobic filter (AF) ? an anaerobic hybrid (AH) + polyurethane-foam trickling filter (PTF). The AF+AH system was operated at a hydraulic retention time (HRT)

  13. Outcomes of single-stage grip-release reconstruction in tetraplegia.

    Science.gov (United States)

    Reinholdt, Carina; Fridén, Jan

    2013-06-01

    To evaluate the outcomes of our technique for single-stage grip-release reconstruction and compare it with previous 1- and 2-stage grip reconstructions in tetraplegia. A total of 14 patients (16 hands) with tetraplegia underwent a single-stage combination of operations to provide pinch, grip, and release function. We compared the study group with a historical control group of 15 patients (18 hands) who had been treated with staged flexion-extension grip-release reconstructions. Both groups were classified as ocular cutaneous 4. Assessment parameters included grip and pinch strength, maximal opening of the first webspace, and Canadian Occupational Performance Measurement. Both groups were rehabilitated with early active mobilization beginning the first day after surgery. Grip strength and opening of the first webspace were significantly greater in the single-stage group than in the comparative group. Pinch strength was not significantly different between groups. On the Canadian Occupational Performance Measurement score, patients belonging to the single-stage group were highly satisfied (increase of 3.7 points) and could perform several of their self-selected goals (3.5 points of improvement). The single-stage grip-release reconstruction provides people who have spinal cord injuries and tetraplegia with improved and reliable grip function; active finger flexion, active thumb flexion, passive thumb extension, and passive interossei function can all be achieved through this procedure. Early active mobilization is particularly important in improving functional outcome after this combination of grip reconstruction procedures. Therapeutic III. Copyright © 2013 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  14. Validation of a PC based program for single stage absorption heat pump

    Science.gov (United States)

    Zaltash, A.; Ally, M. R.

    1991-09-01

    An interactive computer code was developed to evaluate single stage absorption heat pump performance for temperature amplifier and heat amplifier modes using water as the refrigerant. This program performs the cycle calculations for single stage cycles based on the polynomial expressions developed to correlate experimental vapor-liquid-equilibrium (VLE) and specific enthalpy-concentration data for LiBr/water and (Li, K, Na)NO3 water systems as well as the properties of pure water. The operating parameters obtained by this program were tested against mass and energy balances in documented cases and the results show that the maximum deviation between coefficient of performance (COP) values obtained by this software and the ones previously calculated is less than 3 percent. In addition, this program was used to study the effect of solution temperature leaving the absorber on the other operating parameters. This type of analysis could be used to improve and optimize cycle design.

  15. Grid Integration of Single Stage Solar PV System using Three-level Voltage Source Converter

    Science.gov (United States)

    Hussain, Ikhlaq; Kandpal, Maulik; Singh, Bhim

    2016-08-01

    This paper presents a single stage solar PV (photovoltaic) grid integrated power generating system using a three level voltage source converter (VSC) operating at low switching frequency of 900 Hz with robust synchronizing phase locked loop (RS-PLL) based control algorithm. To track the maximum power from solar PV array, an incremental conductance algorithm is used and this maximum power is fed to the grid via three-level VSC. The use of single stage system with three level VSC offers the advantage of low switching losses and the operation at high voltages and high power which results in enhancement of power quality in the proposed system. Simulated results validate the design and control algorithm under steady state and dynamic conditions.

  16. Single-stage osseointegrated implants for nasal prosthodontic rehabilitation: A clinical report.

    Science.gov (United States)

    de Carvalho, Bruna M D F; Freitas-Pontes, Karina M; de Negreiros, Wagner A; Verde, Marcus A R L

    2015-08-01

    Malignant tumors in the nasal region may be treated by means of invasive surgical procedures, with large facial losses. Nasal prostheses, retained by osseointegrated facial implants, instead of plastic surgery, will, in most patients, offer good biomechanical and cosmetic results. This clinical report describes the prosthetic rehabilitation of a patient with nasal cancer who had the entire nasal vestibule removed in a single-stage surgical procedure in order to shorten the rehabilitation time. The nasal prosthesis was built on a 3-magnet bar and was made of platinum silicone with intrinsic pigmentation, thereby restoring the patient's appearance and self-esteem. The authors concluded that single-stage implants may reduce the rehabilitation time to as little as 1 month, and the correct use of materials and techniques may significantly improve the nasal prosthesis. Copyright © 2015 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  17. Single-stage Modified Duhamel procedure for Hirschsprung′s disease : Our experience

    Directory of Open Access Journals (Sweden)

    Paras R Kothari

    2012-01-01

    Full Text Available Introduction: Primary single-stage pull-through for Hirschsprung′s disease (HD has been reported to give comparable surgical outcomes to staged operations with less morbidity. Herein, we present our experience with single-stage Modified Duhamel procedure for management of HD. Patients and Methods: This was a review of 48 cases of HD who underwent single-stage Modified Duhamel procedure without a protective colostomy. Results: The age at surgery ranged from 6 months to 10 years (median - 9 months, mean - 2.3 years. The average weight of the child was 7.2 kg (range, 4.9-22 kg. 38 (79.2% patients had classical rectosigmoid HD, the rest being long segment HD (the proximal most level being the splenic flexure. The average duration of surgery was 175 minutes (range, 130-245 minutes. The average blood loss was 45 ml. The average hospital stay was 7.2 days (range: 6-10 days. The major postoperative complications (n=3 included postoperative adhesive intestinal obstruction, anastomotic leak and persistent constipation due to residual aganglionosis. Each required a re-exploration. Minor complications included surgical site infection (n=3 and post-operative enterocolitis (n=3, which were managed conservatively. Six patients had constipation for a limited period post-operatively. All patients have a satisfactory functional outcome and normal development and growth. Conclusions: For HD, we recommend that single-stage Modified Duhamel procedure should be the preferred approach in view of its low morbidity, satisfactory functional outcome and avoidance of stoma, multiple surgeries and economic benefit in view of decreased hospital stay.

  18. Advanteges of using Two-Switch Forward in Single-Stage Power Factor Corrected Power Supplies

    DEFF Research Database (Denmark)

    Petersen, Lars

    2000-01-01

    A single-Stage power factor corrected power supply using a two-switch forward is proposed to increase efficiency. The converter is operated in the DCM (Discontinues Conduction Mode). This will insure the intermediate DC-bus to be controlled only by means of circuit parameters and therefore...... power supply has been implemented. The measured efficiency and power factor are about 87% and 0.96 respectively....

  19. The first preliminary experiments on an 84 GHz gyrotron with a single-stage depressed collector

    International Nuclear Information System (INIS)

    Shimozuma, T.; Sato, M.; Takita, Y.

    1997-10-01

    We fabricated and tested an 84GHz gyrotron with a single-stage depressed collector. The gyrotron has a high-voltage insulating section made of a low loss silicon nitride composite. In this preliminary experiment in the depressed collector configuration, we obtained 591kW, 41% operation with a depression voltage of 22.5kV. Access to the higher efficiency region was inhibited by an increase in anode current. (author)

  20. System and method for single-phase, single-stage grid-interactive inverter

    Science.gov (United States)

    Liu, Liming; Li, Hui

    2015-09-01

    The present invention provides for the integration of distributed renewable energy sources/storages utilizing a cascaded DC-AC inverter, thereby eliminating the need for a DC-DC converter. The ability to segment the energy sources and energy storages improves the maintenance capability and system reliability of the distributed generation system, as well as achieve wide range reactive power compensation. In the absence of a DC-DC converter, single stage energy conversion can be achieved to enhance energy conversion efficiency.

  1. Adaptive kanban control mechanism for a single-stage hybrid system

    Science.gov (United States)

    Korugan, Aybek; Gupta, Surendra M.

    2002-02-01

    In this paper, we consider a hybrid manufacturing system with two discrete production lines. Here the output of either production line can satisfy the demand for the same type of product without any penalties. The interarrival times for demand occurrences and service completions are exponentially distributed i.i.d. variables. In order to control this type of manufacturing system we suggest a single stage pull type control mechanism with adaptive kanbans and state independent routing of the production information.

  2. Nitrite reduction and methanogenesis in a single-stage UASB reactor.

    Science.gov (United States)

    Borges, L I; López-Vazquez, C M; García, H; van Lier, J B

    2015-01-01

    In this study, nitrite reduction and methanogenesis in a single-stage upflow anaerobic sludge blanket (UASB) reactor was investigated, using high-strength synthetic domestic wastewater as substrate. To assess long-term effects and evaluate the mechanisms that allow successful nitrite reduction and methanogenesis in a single-stage UASB, sludge was exposed to relatively high nitrite loading rates (315 ± 13 mgNO(2)(-)-N/(l.d)), using a chemical oxygen demand (COD) to nitrogen ratio of 18 gCOD/gNO(2)(-)-N, and an organic loading rate of 5.4 ± 0.2 gCOD/(l.d). In parallel, the effects of sludge morphology on methanogenesis inhibition were studied by performing short-term batch activity tests at different COD/NO(2)(-)-N ratios with anaerobic sludge samples. In long-term tests, denitrification was practically complete and COD removal efficiency did not change significantly after nitrite addition. Furthermore, methane production only decreased by 13%, agreeing with the reducing equivalents requirement for complete NO(2)(-) reduction to N₂. Apparently, the spatial separation of denitrification and methanogenesis zones inside the UASB reactor allowed nitrite reduction and methanogenesis to occur at the same moment. Batch tests showed that granules seem to protect methanogens from nitrite inhibition, probably due to transport limitations. Combined COD and N removal via nitrite in a single-stage UASB reactor could be a feasible technology to treat high-strength domestic wastewater.

  3. Single-stage reconstruction of flexor tendons with vascularized tendon transfers.

    Science.gov (United States)

    Cavadas, P C; Pérez-García, A; Thione, A; Lorca-García, C

    2015-03-01

    The reconstruction of finger flexor tendons with vascularized flexor digitorum superficialis (FDS) tendon grafts (flaps) based on the ulnar vessels as a single stage is not a popular technique. We reviewed 40 flexor tendon reconstructions (four flexor pollicis longus and 36 finger flexors) with vascularized FDS tendon grafts in 38 consecutive patients. The donor tendons were transferred based on the ulnar vessels as a single-stage procedure (37 pedicled flaps, three free flaps). Four patients required composite tendon and skin island transfer. Minimum follow-up was 12 months, and functional results were evaluated using a total active range of motion score. Multiple linear regression analysis was performed to evaluate the factors that could be associated with the postoperative total active range of motion. The average postoperative total active range of motion (excluding the thumbs) was 178.05° (SD 50°). The total active range of motion was significantly lower for patients who were reconstructed with free flaps and for those who required composite tendon and skin island flap. Age, right or left hand, donor/motor tendon and pulley reconstruction had no linear effect on total active range of motion. Overall results were comparable with a published series on staged tendon grafting but with a lower complication rate. Vascularized pedicled tendon grafts/flaps are useful in the reconstruction of defects of finger flexor tendons in a single stage, although its role in the reconstructive armamentarium remains to be clearly established. © The Author(s) 2014.

  4. Is Single-stage Revision Safe Following Infected Total Knee Arthroplasty? A Critical Review.

    Science.gov (United States)

    Vaishya, Raju; Agarwal, Amit Kumar; Rawat, Sudheer K; Singh, Harsh; Vijay, Vipul

    2017-08-30

    With the improvement in outcomes and modern prosthesis design, total knee arthroplasty (TKA) has now become a commonly performed surgery. It is postulated that a total of 2-5% of the primary and revision TKA becomes infected every year, requiring a revision procedure which to date is the conventional two-stage revision. The diagnosis and treatment of these periprosthetic infections is a major and challenging task, as it requires precise identification of the pathogen, meticulous debridement, and postoperative rehabilitation. To date, there have been very few studies in existing literature comparing the outcomes of single-stage versus two-stage procedure in infected TKA. The aim of the review was to provide the clinicians an insight into the outcome of the single-stage procedure compared to two-stage procedures and to suggest ways to improve the results further. In the following critical review, a total of 669 cases that underwent either a single or two-stage revision for infected TKA were studied. The postoperative functional scores were comparable in most studies during the early postoperative period. Our data supports the use of a single-stage revision surgery in infected TKA as an alternative to a conventional two-stage procedure. However, larger prospective and multicentric trials are required to validate our findings.

  5. Performance characteristics of an excimer laser (XeCl) with single-stage magnetic pulse compression

    Science.gov (United States)

    Varshnay, N. K.; Singh, A.; Benerji, N. S.

    2017-02-01

    Performance characteristics of an excimer laser (XeCl) with single-stage magnetic pulse compression suitable for material processing applications are presented here. The laser incorporates in-built compact gas circulation and gas cooling to ensure fresh gas mixture between the electrodes for repetitive operation. A magnetically coupled tangential blower is used for gas circulation inside the laser chamber for repetitive operation. The exciter consists of C-C energy transfer circuit and thyratron is used as a high-voltage main switch with single-stage magnetic pulse compression (MPC) between thyratron and the laser electrodes. Low inductance of the laser head and uniform and intense pre-ionization are the main features of the electric circuit used in the laser. A 250 ns rise time voltage pulse was compressed to 100 ns duration with a single-stage magnetic pulse compressor using Ni-Zn ferrite cores. The laser can generate about 150 mJ at ˜100 Hz rep-rate reliably from a discharge volume of 100 cm 3. 2D spatial laser beam profile generated is presented here. The profile shows that the laser beam is completely filled with flat-top which is suitable for material processing applications. The SEM image of the microhole generated on copper target is presented here.

  6. New current control based MPPT technique for single stage grid connected PV systems

    International Nuclear Information System (INIS)

    Jain, Sachin; Agarwal, Vivek

    2007-01-01

    This paper presents a new maximum power point tracking algorithm based on current control for a single stage grid connected photovoltaic system. The main advantage of this algorithm comes from its ability to predict the approximate amplitude of the reference current waveform or power that can be derived from the PV array with the help of an intermediate variable β. A variable step size for the change in reference amplitude during initial tracking helps in fast tracking. It is observed that if the reference current amplitude is greater than the array capacity, the system gets unstable (i.e. moves into the positive slope region of the p-v characteristics of the array). The proposed algorithm prevents the PV system from entering the positive slope region of the p-v characteristics. It is also capable of restoring stability if the system goes unstable due to a sudden environmental change. The proposed algorithm has been tested on a new single stage grid connected PV configuration recently developed by the authors to feed sinusoidal current into the grid. The system is operated in a continuous conduction mode to realize advantages such as low device current stress, high efficiency and low EMI. A fast MPPT tracker with single stage inverter topology operating in CCM makes the overall system highly efficient. Specific cases of the system, operating in just discontinuous current mode and discontinuous current mode and their relative merits and demerits are also discussed

  7. Hydrodynamic effects in trickle bed laboratory reactors for hydrodesulphurization and hydrodemetallization of heavy feeds

    Energy Technology Data Exchange (ETDEWEB)

    Garcia, W.; Pazos, J.M.

    1982-01-01

    Trickle bed reactors are extensively used in the oil industry for hydrotreatment (HDT) of petroleum distillates, removal of impurities, such as sulphur and nitrogen, and hydrocracking. These reactors are also being used for HDT of residua, where hydrodesulphurization (HDS) and hydrodemetallization (HDM) are the key reactions. The purpose of this paper is to study the performance of small trickle bed reactors, at real space velocities used for HDS and HDM of heavy feeds. Particular attention is given to evaluate the effect of the mean particle diameter on reactor behaviour. The final objective is to obtain an empirical model, which considers the influence of the flow conditions and packing properties on reactor performance.

  8. Monte Carlo Error Analysis Applied to Core Formation: The Single-stage Model Revived

    Science.gov (United States)

    Cottrell, E.; Walter, M. J.

    2009-12-01

    The last decade has witnessed an explosion of studies that scrutinize whether or not the siderophile element budget of the modern mantle can plausibly be explained by metal-silicate equilibration in a deep magma ocean during core formation. The single-stage equilibrium scenario is seductive because experiments that equilibrate metal and silicate can then serve as a proxy for the early earth, and the physical and chemical conditions of core formation can be identified. Recently, models have become more complex as they try to accommodate the proliferation of element partitioning data sets, each of which sets its own limits on the pressure, temperature, and chemistry of equilibration. The ability of single stage models to explain mantle chemistry has subsequently been challenged, resulting in the development of complex multi-stage core formation models. Here we show that the extent to which extant partitioning data are consistent with single-stage core formation depends heavily upon (1) the assumptions made when regressing experimental partitioning data (2) the certainty with which regression coefficients are known and (3) the certainty with which the core/mantle concentration ratios of the siderophile elements are known. We introduce a Monte Carlo algorithm coded in MATLAB that samples parameter space in pressure and oxygen fugacity for a given mantle composition (nbo/t) and liquidus, and returns the number of equilibrium single-stage liquidus “solutions” that are permissible, taking into account the uncertainty in regression parameters and range of acceptable core/mantle ratios. Here we explore the consequences of regression parameter uncertainty and the impact of regression construction on model outcomes. We find that the form of the partition coefficient (Kd with enforced valence state, or D) and the handling of the temperature effect (based on 1-atm free energy data or high P-T experimental observations) critically affects model outcomes. We consider the most

  9. Minimally Invasive, Single-Stage, Multilevel Surgery for Obstructive Sleep Apnea in Asian Patients.

    Science.gov (United States)

    Lin, Hsin-Ching; Friedman, Michael; Chang, Hsueh-Wen; Bonzelaar, Lauren; Salapatas, Anna M; Lin, Meng-Chih; Huang, Kuo-Tung

    2017-02-01

    This study adds to the literature on the efficacy and low complication rates associated with minimally invasive, single-stage, multilevel surgery for Asian adults with obstructive sleep apnea (OSA) for whom conservative treatment had failed. Overall, our experience has produced results that make this procedure an option for select patients with snoring and OSA. To investigate the effectiveness and safety of anatomy-based, minimally invasive, single-stage, multilevel surgery in the treatment of OSA in an Asian population. This retrospective study enrolled 59 consecutive patients with OSA from a tertiary academic medical center who had multilevel obstruction and unsuccessful conservative therapy and then underwent minimally invasive, single-stage, multilevel surgery. The subjective symptoms and objective polysomnographic findings were collected preoperatively and at a minimum of 3 months postoperatively. The Global Patient Assessment questionnaire was used to assess patient satisfaction after minimally invasive, single-stage, multilevel surgery. Scores on the Epworth Sleepiness Scale and bed partner evaluation of patient's snoring on a visual analog scale (scale of 0-10, with 0 indicating no snoring and 10 indicating the bed partner to leave the room or sleep separately, as assessed by the bed partner). The primary outcomes are a 50% decrease in bed partner's snoring visual analog scale level postoperatively and an improvement of 50% or more in apnea-hypopnea index by an at least 3-month follow-up. Adverse events and patient-reported quality measures were also assessed. Forty-seven patients (36 men and 11 women; mean [SD], 47.3 [10.9] years) with a minimum 3-month follow-up and complete data were included in the analysis. None of the patients had serious perioperative or postoperative complications. Three months postoperatively, the mean (SD) scores on the Epworth Sleepiness Scale and bed partner evaluation of patient's snoring on the visual analog scale decreased

  10. The function of a toluene-degrading bacterial community in a waste gas trickling filter

    DEFF Research Database (Denmark)

    Pedersen, A.R.; Arvin, E.

    1999-01-01

    ) during two weeks. In spite of the low fraction in the biofilm, the toluene degraders supported growth of the dominating part of non-toluene-degrading heterotrophs in the biofilm, as toluene was the sole carbon source supplied to the system. The maximum intrinsic growth rate of P. putida in the biofilm......The function of a community of toluene-degrading bacteria in a biofilm system was investigated with regard to growth and toluene degradation in order to investigate substrate interactions in the community. This was done by the combination of experimental observations using a specific...... and the activity of P. putida, a representative of the toluene-degrading species in the biofilm which have been described previously (Pedersen et al., 1997) were simulated. The simulation indicated that the volume fraction of the toluene degraders in the biofilm decreased from 12% to only 2% (11% of dry weight...

  11. Anaerobic ammonium oxidation in the old trickling filters at Daspooort wastewater treatment works

    CSIR Research Space (South Africa)

    Wilsenach, J

    2014-01-01

    Full Text Available _(sup+)-N) and nitrite-nitrogen (NO(sub2)(sup-)-N). These reactors were subsequently monitored by conducting stoichiometric analyses of chemical oxygen demand (COD), NH(sub4)(sup+)-N, NO(sub2)(sup-)-N, and nitrate-nitrogen (NO(sub3)(sup...

  12. Bioavailable and biodegradable dissolved organic nitrogen in activated sludge and trickling filter wastewater treatment plants

    Science.gov (United States)

    A study was carried out to understand the fate of biodegradable dissolved organic nitrogen (BDON) and bioavailable dissolved organic nitrogen (ABDON) along the treatment trains of a wastewater treatment facility (WWTF) equipped with an activated sludge (AS) system and a WWTF equipped with a two-stag...

  13. Methanol synthesis in a countercurrent gas-solid-solid trickle flow reactor. An experimental study

    NARCIS (Netherlands)

    Kuczynski, M.; Oyevaar, M.H.; Pieters, R.T.; Westerterp, K.R.

    1987-01-01

    The synthesis of methanol from CO and H2 was executed in a gas-solid-solid trickle flow reactor. The reactor consisted of three tubular reactor sections with cooling sections in between. The catalyst was Cu on alumina, the adsorbent was a silica-alumina powder and the experimental range 498–523 K,

  14. CO2 capture in a continuous gas–solid trickle flow reactor

    NARCIS (Netherlands)

    Veneman, Rens; Hilbers, T.J.; Brilman, Derk Willem Frederik; Kersten, Sascha R.A.

    2016-01-01

    This paper describes the selection, design and experimental validation of a gas–solid trickle flow adsorber for post-combustion CO2 capture using a supported amine sorbents (Lewatit® VP OC 1065). The experimental work presented here summarizes over 300 h of operating experience, which is equivalent

  15. How to prevent runaways in trickle-bed reactors for Pygas hydrogenation

    NARCIS (Netherlands)

    Westerterp, K.R.; Kronberg, Alexandre E.

    2002-01-01

    In the past, several runaways have occurred in Trickle-Bed Reactors (TBR) used for the hydrogenation of pyrolysis gasoline as produced in ethylene cracking installations. This phenomenon has been studied in the framework of a special program in the Netherlands, which is administered by the National

  16. Experimental single and trickle infections of cattle with Taenia saginata: Studies of immunodiagnosis

    DEFF Research Database (Denmark)

    Bøgh, H.O.; Grønvold, J.; Maeda, G.E.

    1996-01-01

    Two groups of 12 calves were given either a single infection dose of 30,000 Taenia saginata eggs (group A) or trickle infected with 12 x 2500 T saginata eggs (group B). The calves were killed 16, 22 or 54 weeks after infection and the numbers of viable and dead parasites were counted by slicing...

  17. Evaluation of Bamboo Porous Pipe as Line Source Emitter in Trickle ...

    African Journals Online (AJOL)

    This paper attempts to evaluate the use of bamboo as porous pipe (line source) emitter in trickle irrigation at the Cross River University of Technology Teaching and Research Farm Obubra. Two sets of bamboo laterals: opened and plugged ends were used for the trial. The experiment was conducted using four different ...

  18. [Single-stage bilateral Pemberton's pericapsular osteotomy in bilateral developmental dysplasia of the hip].

    Science.gov (United States)

    Zorer, Gazi; Bagatur, A Erdem

    2002-01-01

    This study was designed to evaluate the results of single-stage bilateral Pemberton's pericapsular osteotomy with or without open reduction and to demonstrate its advantages over two separate consecutive interventions in bilateral developmental dysplasia of the hip (DDH). This prospective study included 20 patients (14 girls, 6 boys; mean age 30 months; range 12 to 60 months) with bilateral DDH, who underwent single-stage bilateral Pemberton's pericapsular osteotomy with (14 patients, group A1) or without (6 patients, group A2) open reduction. Twenty patients (16 girls, 4 boys; mean age 24 months; range 13 to 47 months) with unilateral DDH, who underwent Pemberton's pericapsular osteotomy with (12 patients, group B1) or without (8 patients, group B2) open reduction were enrolled into the study as controls. Single- and two-stage procedures were compared with regard to improvement in the acetabular index, complications, mean duration of anesthesia, perioperative need for blood transfusion, length of hospital stay, initiation of walking, overall cost of antibiotic prophylaxis, and total hospital charge. There were no significant differences between A1 and B1, A2 and B2 groups with respect to mean age, gender, pre- and postoperative acetabular indices, and recovery times. However, duration of anesthesia, length of hospital stay, cost of antibiotic prophylaxis, and total hospital charges differed significantly. The amount of blood transfusion differed significantly only between groups A1 and B1. The length of hospital stay and cost of antibiotic prophylaxis in group A2 was twice as much as that of group B2. Increases in other parameters ranged between 22% to 37%. No early or late complications were encountered. Single-stage bilateral Pemberton's pericapsular osteotomy in patients with bilateral DDH seems to have significant advantages over two separate consecutive interventions. However, increased risks of bilateral osteotomies require that sufficiently equipped and

  19. Single-stage electrohydraulic servosystem for actuating on airflow valve with frequencies to 500 hertz

    Science.gov (United States)

    Webb, J. A., Jr.; Mehmed, O.; Lorenzo, C. F.

    1980-01-01

    An airflow valve and its electrohydraulic actuation servosystem are described. The servosystem uses a high-power, single-stage servovalve to obtain a dynamic response beyond that of systems designed with conventional two-stage servovalves. The electrohydraulic servosystem is analyzed and the limitations imposed on system performance by such nonlinearities as signal saturations and power limitations are discussed. Descriptions of the mechanical design concepts and developmental considerations are included. Dynamic data, in the form of sweep-frequency test results, are presented and comparison with analytical results obtained with an analog computer model is made.

  20. The Lifetime Estimate for ACSR Single-Stage Splice Connector Operating at Higher Temperatures

    International Nuclear Information System (INIS)

    Wang, Jy-An John; Graziano, Joe; Chan, John

    2011-01-01

    This paper is the continuation of Part I effort to develop a protocol of integrating analytical and experimental approaches to evaluate the integrity of a full tension single-stage splice connector (SSC) assembly during service at high operating temperature.1The Part II efforts are mainly focused on the thermal mechanical testing, thermal-cycling simulation and its impact on the effective lifetime of the SSC system. The investigation indicates that thermal cycling temperature and frequency, conductor cable tension loading, and the compressive residual stress field within a SSC system have significant impact on the SSC integrity and the associated effective lifetime.

  1. 85,000-GPM, single-stage, single-suction LMFBR intermediate centrifugal pump

    International Nuclear Information System (INIS)

    Fair, C.E.; Cook, M.E.; Huber, K.A.; Rohde, R.

    1983-01-01

    The mechanical and hydraulic design features of the 85,000-gpm, single-stage, single-suction pump test article, which is designed to circulate liquid-sodium coolant in the intermediate heat-transport system of a Large-Scale Liquid Metal Fast Breeder Reactor (LS-LMFBR), are described. The design and analytical considerations used to satisfy the pump performance and operability requirements are presented. The validation of pump hydraulic performance using a hydraulic scale-model pump is discussed, as is the featute test for the mechanical-shaft seal system

  2. Fault Diagnosis for Engine Based on Single-Stage Extreme Learning Machine

    Directory of Open Access Journals (Sweden)

    Fei Gao

    2016-01-01

    Full Text Available Single-Stage Extreme Learning Machine (SS-ELM is presented to dispose of the mechanical fault diagnosis in this paper. Based on it, the traditional mapping type of extreme learning machine (ELM has been changed and the eigenvectors extracted from signal processing methods are directly regarded as outputs of the network’s hidden layer. Then the uncertainty that training data transformed from the input space to the ELM feature space with the ELM mapping and problem of the selection of the hidden nodes are avoided effectively. The experiment results of diesel engine fault diagnosis show good performance of the SS-ELM algorithm.

  3. Simulation model of a single-stage lithium bromide-water absorption cooling unit

    Science.gov (United States)

    Miao, D.

    1978-01-01

    A computer model of a LiBr-H2O single-stage absorption machine was developed. The model, utilizing a given set of design data such as water-flow rates and inlet or outlet temperatures of these flow rates but without knowing the interior characteristics of the machine (heat transfer rates and surface areas), can be used to predict or simulate off-design performance. Results from 130 off-design cases for a given commercial machine agree with the published data within 2 percent.

  4. Promising results after single-stage reconstruction of the nipple and areola complex

    DEFF Research Database (Denmark)

    Børsen-Koch, Mikkel; Bille, Camilla; Thomsen, Jørn B

    2013-01-01

    a technique based on a local flap for reconstruction of the nipple in combination with immediate intradermal tattooing for reconstruction of the areola. Results: We reviewed the outcome of 22 cases of women who had simple single-stage reconstruction over a period of one year. We found no major and only two...... minor complications including one case of partial flap necrosis and one case of infection. Only three patients needed additional tattooing after a three-month period. The cosmetic outcome was satisfactory and none of the patients needed corrective procedures. The mean procedure time for unilateral...

  5. Performance of the rebuilt SUERC single-stage accelerator mass spectrometer

    Science.gov (United States)

    Shanks, Richard P.; Ascough, Philippa L.; Dougans, Andrew; Gallacher, Paul; Gulliver, Pauline; Rood, Dylan H.; Xu, Sheng; Freeman, Stewart P. H. T.

    2015-10-01

    The SUERC bipolar single-stage accelerator mass spectrometer (SSAMS) has been dismantled and rebuilt to accommodate an additional rotatable pre-accelerator electrostatic spherical analyser (ESA) and a second ion source injector. This is for the attachment of an experimental positive-ion electron cyclotron resonance (ECR) ion source in addition to a Cs-sputter source. The ESA significantly suppresses oxygen interference to radiocarbon detection, and remaining measurement interference is now thought to be from 13C injected as 13CH molecule scattering off the plates of a second original pre-detector ESA.

  6. Design and analysis of a single stage to orbit nuclear thermal rocket reactor engine

    Energy Technology Data Exchange (ETDEWEB)

    Labib, Satira, E-mail: Satira.Labib@duke-energy.com; King, Jeffrey, E-mail: kingjc@mines.edu

    2015-06-15

    Graphical abstract: - Highlights: • Three NTR reactors are optimized for the single stage launch of 1–15 MT payloads. • The proposed rocket engines have specific impulses in excess of 700 s. • Reactivity and submersion criticality requirements are satisfied for each reactor. - Abstract: Recent advances in the development of high power density fuel materials have renewed interest in nuclear thermal rockets (NTRs) as a viable propulsion technology for future space exploration. This paper describes the design of three NTR reactor engines designed for the single stage to orbit launch of payloads from 1 to 15 metric tons. Thermal hydraulic and rocket engine analyses indicate that the proposed rocket engines are able to reach specific impulses in excess of 800 s. Neutronics analyses performed using MCNP5 demonstrate that the hot excess reactivity, shutdown margin, and submersion criticality requirements are satisfied for each NTR reactor. The reactors each consist of a 40 cm diameter core packed with hexagonal tungsten cermet fuel elements. The core is surrounded by radial and axial beryllium reflectors and eight boron carbide control drums. The 40 cm long reactor meets the submersion criticality requirements (a shutdown margin of at least $1 subcritical in all submersion scenarios) with no further modifications. The 80 and 120 cm long reactors include small amounts of gadolinium nitride as a spectral shift absorber to keep them subcritical upon submersion in seawater or wet sand following a launch abort.

  7. Heavy metal bioleaching and sludge stabilization in a single-stage reactor using indigenous acidophilic heterotrophs.

    Science.gov (United States)

    Mehrotra, Akanksha; Sreekrishnan, T R

    2017-11-01

    Simultaneous sludge digestion and metal leaching (SSDML) have been reported at mesophilic temperature. It is generally perceived that while sludge stabilization is effected by heterotrophs at neutral pH, metal bioleaching is done by acidophilic autotrophs. However, little information is available on the microbial communities involved in the process. This study carried out SSDML in a single-stage reactor using sludge indigenous microorganisms and looked at the bacterial communities responsible for the process. Volatile suspended solids were reduced by more than 40%. The concentration of zinc, copper, chromium, cadmium and nickel decreased by more than 45% in the dry sludge. Acidophilic species of Alicyclobacillus genus were the dominant heterotrophs. A few heterotrophic bacteria were detected which can oxidize iron (Alicyclobacillus ferrooxydans, Alicyclobacillus ferripilum and Ferrimicrobium acidiphilum). Acidithiobacillus ferrooxidans (autotroph) was responsible for the oxidation of both iron and sulfur which lead to a change in the pH from neutral to acidic. The presence of acidophilic heterotrophs, which can oxidize either iron or sulfur, enhanced the efficiency of SSDML process with respect to sludge stabilization and metal leaching. This study shows that it is possible to carry out the SSDML in a single-stage reactor with indigenous microorganisms.

  8. Red Mud Catalytic Pyrolysis of Pinyon Juniper and Single-Stage Hydrotreatment of Oils

    Energy Technology Data Exchange (ETDEWEB)

    Agblevor, Foster A.; Elliott, Douglas C.; Santosa, Daniel M.; Olarte, Mariefel V.; Burton, Sarah D.; Swita, Marie; Beis, Sedat H.; Christian, Kyle; Sargent, Brandon

    2016-10-20

    Pinyon juniper biomass feedstocks, which cover a large acreage of rangeland in the western United States, are being eradicated and, therefore, considered as a convenient biomass feedstock for biofuel production. Pinyon juniper whole biomass (wood, bark, and leaves) were pyrolyzed in a pilot-scale bubbling fluidized-bed reactor at 450 °C, and the noncondensable gases were recycled to fluidize the reactor. Red mud was used as the in situ catalyst for the pyrolysis of the pinyon juniper biomass. The pyrolysis products were condensed in three stages, and products were analyzed for physicochemical properties. The condenser oil formed two phases with the aqueous fraction, whereas the electrostatic precipitator oils formed a single phase. The oil pH was 3.3; the higher heating value (HHV) was 28 MJ/kg; and the viscosity was less than 100 cP. There was a direct correlation between the viscosity of the oils and the alcohol/ether content of the oils, and this was also related to the aging rate of the oils. The catalytic pyrolysis oils were hydrotreated in a continuous single-stage benchtop hydrotreater to produce hydrocarbon fuels with a density of 0.80$-$0.82 cm3/g. The hydrotreater ran continuously for over 300 h with no significant catalyst deactivation or coke formation. This is the first time that such a long single-stage hydrotreatment has been demonstrated on biomass catalytic pyrolysis oils.

  9. Single-stage micro-scale solvent extraction in parallel microbore tubes using MDIMJ

    International Nuclear Information System (INIS)

    Darekar, Mayur; Singh, K.K.; Joshi, J.M.; Mukhopadhyay, S.; Shenoy, K.T.

    2016-01-01

    Single-stage micro-scale solvent extraction of U(VI) from simulated lean streams is explored using micro-scale contactor comprising of a MDIMJ (Monoblock Distributor with Integrated Microfluidic Junction) and PTFE microbore tubes. 30% (v/v) TBP in dodecane has been used as the extracting phase. The objective of the study is to demonstrate numbering up approach for scale-up of micro-scale extraction using indigenously conceptualized and fabricated MDIMJ. First the performance of MIDIMJ for equal flow distribution is tested. Then the effects of inlet flow rate and O/A ratio on stage efficiency and percentage extraction are studied. The experiments show that it is easy to scale-up single-stage micro-scale solvent extraction by using MDIMJ for numbering up approach. Maximum capacity tested is 4.8 LPH. With O/A = 2/1, more than 90% extraction is achieved in a very short contact time of less than 3s. The study thus demonstrates possibility of process intensification and easy scale-up of micro-scale solvent extraction

  10. A single stage to orbit rocket with non-cryogenic propellants

    Science.gov (United States)

    Clapp, Mitchell B.; Hunter, Maxwell W.

    1993-06-01

    Different propellant combinations for single-stage-to-orbit-rocket applications were compared to oxygen/hydrogen, including nitrogen tetroxide/hydrazine, oxygen/methane, oxygen/propane, oxygen/RP-1, solid core nuclear/hydrogen, and hydrogen peroxide/JP-5. Results show that hydrogen peroxide and JP-5, which have a specific impulse of 328 s in vacuum and a density of 1,330 kg/cu m. This high-density jet fuel offers 1.79 times the payload specific energy of oxygen and hydrogen. By catalytically decomposing the hydrogen peroxide to steam and oxygen before injection into the thrust chamber, the JP-5 can be injected as a liquid into a high-temperature gas flow. This would yield superior combustion stability and permit easy throttling of the engine by adjusting the amount of JP-5 in the mixture. It is concluded that development of modern hydrogen peroxide/JP-5 engines, combined with modern structural technology, could lead to a simple, robust, and versatile single-stage-to-orbit capability.

  11. Performance evaluation of a piezoactuator-based single-stage valve system subjected to high temperature

    International Nuclear Information System (INIS)

    Jeon, Juncheol; Han, Chulhee; Ung Chung, Jye; Choi, Seung-Bok

    2015-01-01

    In this paper, a novel single-stage valve system activated by a piezostack actuator is proposed and experimentally evaluated at both room temperature (20 °C) and high temperature (100 °C) conditions. A hinge-lever displacement amplifier is adopted in the valve system to magnify the displacement generated from the piezostack actuator. After explaining the operating principle of the proposed piezostack-driven single-stage valve system, the geometric dimensions and mechanical properties of the valve components are discussed in details. An experimental apparatus is then manufactured to evaluate the performances of the valve system such as flow rate. The experimental apparatus consists of a heat chamber, which can regulate the temperature of the valve system and oil, pneumatic-hydraulic cylinders, a hydraulic circuit, a pneumatic circuit, electronic devices, an interface card, and a high voltage amplifier. The pneumatic-hydraulic cylinder transforms the pneumatic pressure into hydraulic pressure. The performances of the valve system regarding spool response, pressure drop, and flow rate are evaluated and presented. In addition, the performance of the valve system under high temperature condition is compared with that under room temperature condition. The experimental results are plotted in both frequency and time domains. (paper)

  12. Design and analysis of a radial diffuser in a single-stage centrifugal pump

    Directory of Open Access Journals (Sweden)

    Ming-Gao Tan

    2016-01-01

    Full Text Available Radial diffusers can improve the flow uniformity in pumps and affect the hydraulic performance of centrifugal pumps directly. The diffusion coefficient d is an important parameter in fluid machinery but it has seldom been used in the diffuser design of single-stage centrifugal pumps. To improve the design method of radial diffuser use in centrifugal pumps, the diffusion coefficient was introduced into the design of radial diffusers based on a single-arc hydraulic design method and it was found that the vane outlet angle, vane outlet thickness and vane number have a significant impact on the design results. A single-stage centrifugal pump with a radial diffuser was selected as the research model. The inner flow was simulated using the commercial computational fluid dynamics (CFD program CFX and verified by experiment. The results indicate that the head and efficiency of the pump are best when the vane outlet angle is 6°. The flow area decreases and the flow velocity at radial diffuser outlet increase when the outlet thickness is greater than 2 mm. The hydraulic loss is minimum and the head and efficiency are better when the vane number is 8 at different flow rates. So, the optimal range of the diffusion coefficient for the model pump is around 1.6 to 2. The study indicates that it is feasible to design radial diffusers according to the diffusion coefficient.

  13. Lengthening Temporalis Myoplasty for Single-Stage Smile Reconstruction in Children with Facial Paralysis.

    Science.gov (United States)

    Panossian, Andre

    2016-04-01

    Free muscle transfer for dynamic smile reanimation in facial paralysis is not always predictable with regard to cosmesis. Hospital stays range from 5 to 7 days. Prolonged operative times, longer hospital stays, and excessive cheek bulk are associated with free flap options. Lengthening temporalis myoplasty offers single-stage smile reanimation with theoretical advantages over free tissue transfer. From 2012 to 2014, 18 lengthening temporalis myoplasties were performed in 14 children for smile reconstruction. A retrospective chart review was completed for demographics, operative times, length of hospital stay, and perioperative complications. Fourteen consecutive patients with complete facial paralysis were included. Four patients underwent single-stage bilateral reconstruction, and 10 underwent unilateral procedures. Diagnoses included Möbius syndrome (n = 5), posterior cranial fossa tumors (n = 4), posttraumatic (n = 2), hemifacial microsomia (n = 1), and idiopathic (n = 2). Average patient age was 10.1 years. Average operative time was 410 minutes (499 minutes for bilateral lengthening temporalis myoplasty and 373 for unilateral lengthening temporalis myoplasty). Average length of stay was 3.3 days (4.75 days for bilateral lengthening temporalis myoplasty and 2.8 for unilateral lengthening temporalis myoplasty). Nine patients required minor revisions. Lengthening temporalis myoplasty is a safe alternative to free tissue transfer for dynamic smile reconstruction in children with facial paralysis. Limited donor-site morbidity, shorter operative times, and shorter hospital stays are some benefits over free flap options. However, revisions are required frequently secondary to tendon avulsions and adhesions. Therapeutic, IV.

  14. Hearing rehabilitation with single-stage bilateral vibroplasty in a child with Franceschetti syndrome.

    Science.gov (United States)

    Sargsyan, Sona; Rahne, Torsten; Kösling, Sabrina; Eichler, Gerburg; Plontke, Stefan K

    2014-05-01

    Hearing is of utmost importance for normal speech and social development. Even children who have mild or unilateral permanent hearing loss may experience difficulties with understanding speech, as well as problems with educational and psycho-social development. The increasing advantages of middle-ear implant technologies are opening new perspectives for restoring hearing. Active middle-ear implants can be used in children and adolescents with hearing loss. In addition to the well-documented results for improving speech intelligibility and quality of hearing in sensorineural hearing loss active middle-ear implants are now successfully used in patients with conductive and mixed hearing loss. In this article we present a case of successful, single-stage vibroplasty, on the right side with the fixation of the FMT on the stapes and PORP CLiP vibroplasty on the left side in a 6-year-old girl with bilateral mixed hearing loss and multiple dyslalia associated with Franceschetti syndrome (mandibulofacial dysostosis). CT revealed bilateral middle-ear malformations as well as an atretic right and stenotic left external auditory canal. Due to craniofacial dysmorphia airway and (post)operative, management is significantly more difficult in patients with a Franceschetti syndrome which in this case favoured a single-stage bilateral procedure. No intra- or postoperative surgical complications were reported. The middle-ear implants were activated 4 weeks after surgery. In the audiological examination 6 months after surgery, the child showed 100% speech intelligibility with activated implants on each side.

  15. In-situ sludge pretreatment in a single-stage anaerobic digester.

    Science.gov (United States)

    Chen, Yun; Xiao, Keke; Jiang, Xie; Shen, Nan; Zeng, Raymond J; Zhou, Yan

    2017-08-01

    This study aimed to develop an in-situ sludge pretreatment method by increasing the temperature from thermophilic to extreme thermophilic condition in a single-stage anaerobic digester. The results revealed that a stable performance was obtained within the temperature range of 55-65°C, and the maximum methane yield of 208.51±13.66mL/g VS was obtained at 65°C. Moreover, the maximum extent of hydrolysis (33%) and acidification (27.1%) was also observed at 65°C. However, further increase of temperature to 70°C did not improve the organic conversion efficiency. Microbial community analysis revealed that Coprothermobacter, highly related to acetate oxidisers, appeared to be the abundant bacterial group at higher temperature. A progressive shift in methanogenic members from Methanosarcina to Methanothermobacter was observed upon increasing the temperature. This work demonstrated single-stage sludge digestion system can be successfully established at high temperature (65°C) with stable performance, which can eliminate the need of conventional thermophilic pretreatment step. Copyright © 2017 Elsevier Ltd. All rights reserved.

  16. A single-stage polymerase-based protocol for the introduction of deletions and insertions without subcloning.

    Science.gov (United States)

    Salerno, John C; Jones, Rachel J; Erdogan, Eda; Smith, Susan M E

    2005-03-01

    A single-stage polymerase-based procedure is described that allows extensive modifications of DNA. The version described here uses the QuikChange Site-Directed Mutagenesis System kit supplied by Stratagene. The original protocol is replaced by a single-stage method in which linear production of complementary strands is accomplished in separate single primer reactions. This has proved effective in introducing insertions and deletions into large gene/vector combinations without subcloning.

  17. Single-stage gain-clamped L-band EDFA with C-band ASE self-oscillation in ring cavity

    International Nuclear Information System (INIS)

    Mahdi, M A; Al-Mansoori, M H; Bakar, A A A; Shaari, S; Zamzuri, A K

    2008-01-01

    We demonstrate single-stage gain-clamped L-band Er 3+ -doped fiber amplifier (EDFA) utilizing self-oscillation modes as the control light. The amplifier structure exploits the characteristics of C/L-band coupler to isolate between lasing modes and L-band signal. The self-lasing cavity modes are obtained without any tunable bandpass filter in the loop and generated from the amplified spontaneous emission in the C-band region. The amplifier configuration has lower noise figures as opposed to a dual-stage partially gain-clamped amplifier. The gain and noise figure fluctuations are less than ± 0.4 dB in the gain-clamping region. The transient analysis confirms that the maximum power excursion is less than 0.3 dB for 10-dB add/drop

  18. Plasma gasification of refuse derived fuel in a single-stage system using different gasifying agents.

    Science.gov (United States)

    Agon, N; Hrabovský, M; Chumak, O; Hlína, M; Kopecký, V; Masláni, A; Bosmans, A; Helsen, L; Skoblja, S; Van Oost, G; Vierendeels, J

    2016-01-01

    The renewable evolution in the energy industry and the depletion of natural resources are putting pressure on the waste industry to shift towards flexible treatment technologies with efficient materials and/or energy recovery. In this context, a thermochemical conversion method of recent interest is plasma gasification, which is capable of producing syngas from a wide variety of waste streams. The produced syngas can be valorized for both energetic (heat and/or electricity) and chemical (ammonia, hydrogen or liquid hydrocarbons) end-purposes. This paper evaluates the performance of experiments on a single-stage plasma gasification system for the treatment of refuse-derived fuel (RDF) from excavated waste. A comparative analysis of the syngas characteristics and process yields was done for seven cases with different types of gasifying agents (CO2+O2, H2O, CO2+H2O and O2+H2O). The syngas compositions were compared to the thermodynamic equilibrium compositions and the performance of the single-stage plasma gasification of RDF was compared to that of similar experiments with biomass and to the performance of a two-stage plasma gasification process with RDF. The temperature range of the experiment was from 1400 to 1600 K and for all cases, a medium calorific value syngas was produced with lower heating values up to 10.9 MJ/Nm(3), low levels of tar, high levels of CO and H2 and which composition was in good agreement to the equilibrium composition. The carbon conversion efficiency ranged from 80% to 100% and maximum cold gas efficiency and mechanical gasification efficiency of respectively 56% and 95%, were registered. Overall, the treatment of RDF proved to be less performant than that of biomass in the same system. Compared to a two-stage plasma gasification system, the produced syngas from the single-stage reactor showed more favourable characteristics, while the recovery of the solid residue as a vitrified slag is an advantage of the two-stage set-up. Copyright

  19. Performance of non woven synthetic fabric and disc filters for fertirrigation water treatment

    OpenAIRE

    Ribeiro,Túlio Assunção Pires; Paterniani,José Euclides Stipp; Airoldi,Rogério Pereira da Silva; Silva,Marcelo Jacomini Moreira da

    2004-01-01

    Obstruction of emitters caused by the presence of solid particles in the water raises the cost and maintenance of trickle irrigation systems, and might compromise their utilization. This research was performed through test fields, with the objective of evaluating the performance of a disc filter (130 microns) and a non woven synthetic fabric filter on the removal of physical, chemical and biological impurities from the irrigation water, which may cause emitter obstruction during fertirrigatio...

  20. Magnesium isotope evidence for single stage formation of CB chondrules by colliding planetesimals

    DEFF Research Database (Denmark)

    Olsen, Mia Bjørg Stolberg; Schiller, Martin; Krot, Alexander N.

    2013-01-01

    Chondrules are igneous spherical objects preserved in chondritic meteorites and believed to have formed during transient heating events in the solar protoplanetary disk. Chondrules present in the metal-rich CB chondrites show unusual chemical and petrologic features not observed in other chondrite...... groups, implying a markedly distinct formation mechanism. Here, we report high-precision Mg-isotope data for 10 skeletal olivine chondrules from the Hammadah al Hamra 237 (HH237) chondrite to probe the formation history of CB chondrules. The Al/Mg ratios of individual chondrules are positively correlated...... to their stable Mg-isotope composition (μMg), indicating that the correlated variability was imparted by a volatility-controlled process (evaporation/condensation). The mass-independent Mg composition (μMg*) of chondrules is consistent with single stage formation from an initially homogeneous magnesium reservoir...

  1. Aeration Strategies To Mitigate Nitrous Oxide Emissions from Single-Stage Nitritation/Anammox Reactors

    DEFF Research Database (Denmark)

    Domingo Felez, Carlos; Mutlu, A. Gizem; Jensen, Marlene Mark

    2014-01-01

    Autotrophic nitrogen removal is regarded as a resource efficient process to manage nitrogen-rich residual streams. However, nitrous oxide emissions of these processes are poorly documented and strategies to mitigate emissions unknown. In this study, two sequencing batch reactors performing single......-stage nitritation/anammox were operated under different aeration strategies, gradually adjusted over six months. At constant but limiting oxygen loading, synthetic reject water was fed (0.75g-N/L.d) and high nitrogen removal efficiencies (83 +/- 5 and 88 +/- 2%) obtained. Dynamics of liquid phase nitrous (N2O......) and nitric oxide (NO) concentrations were monitored and N2O emissions calculated. Significant decreases in N2O emissions were obtained when the frequency of aeration was increased while maintaining a constant air flow rate (from >6 to 1.7% Delta N2O/Delta TN). However, no significant effect on the emissions...

  2. Multi-disciplinary design optimization and performance evaluation of a single stage transonic axial compressor

    International Nuclear Information System (INIS)

    Lee, Sae Il; Lee, Dong Ho; Kim, Kyu Hong; Park, Tae Choon; Lim, Byeung Jun; Kang, Young Seok

    2013-01-01

    The multidisciplinary design optimization method, which integrates aerodynamic performance and structural stability, was utilized in the development of a single-stage transonic axial compressor. An approximation model was created using artificial neural network for global optimization within given ranges of variables and several design constraints. The genetic algorithm was used for the exploration of the Pareto front to find the maximum objective function value. The final design was chosen after a second stage gradient-based optimization process to improve the accuracy of the optimization. To validate the design procedure, numerical simulations and compressor tests were carried out to evaluate the aerodynamic performance and safety factor of the optimized compressor. Comparison between numerical optimal results and experimental data are well matched. The optimum shape of the compressor blade is obtained and compared to the baseline design. The proposed optimization framework improves the aerodynamic efficiency and the safety factor.

  3. Investigation of Single-Stage Modified Turbine of Mark 25 Torpedo Power Plant

    Science.gov (United States)

    Hoyt, Jack W.

    1947-01-01

    Efficiency investigations have been made on a single-stage modification of the turbine of a Mark 25 aerial torpedo to determine the performance of the unit with five different turbine nozzles. The output of the turbine blades was computed by analyzing the windage and mechanical-friction losses of the unit. The turbine was faund to be most efficient with a cast nozzle having sharp-edged inlets to the nine nozzle ports. An analysis af the effectiveness af the first and second stages of the standard Mark 25 torpedo turbine indicates that the first- stage turbine contributes nearly all the brake power produced at blade-jet speed ratios above 0.26.

  4. The Integrity of ACSR Full Tension Single-Stage Splice Connector at Higher Operation Temperature

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Jy-An John [ORNL; Lara-Curzio, Edgar [ORNL; King Jr, Thomas J [ORNL

    2008-10-01

    Due to increases in power demand and limited investment in new infrastructure, existing overhead power transmission lines often need to operate at temperatures higher than those used for the original design criteria. This has led to the accelerated aging and degradation of splice connectors. It is manifested by the formation of hot-spots that have been revealed by infrared imaging during inspection. The implications of connector aging is two-fold: (1) significant increases in resistivity of the splice connector (i.e., less efficient transmission of electricity) and (2) significant reductions in the connector clamping strength, which could ultimately result in separation of the power transmission line at the joint. Therefore, the splice connector appears to be the weakest link in electric power transmission lines. This report presents a protocol for integrating analytical and experimental approaches to evaluate the integrity of full tension single-stage splice connector assemblies and the associated effective lifetime at high operating temperature.

  5. Clean-chemistry synthesis of 2-tetralones in a single-stage acylation-cycloalkylation process.

    Science.gov (United States)

    Gray, A D; Smyth, T P

    2001-10-19

    The preparation of substituted-2-tetralones by direct reaction of a 1-alkene with a substituted phenylacetic acid in a reaction system of trifluoroacetic anhydride (TFAA) and phosphoric acid is described. This single-stage process involves in situ formation of a mixed anhydride of the phenylacetic acid and acylation of the alkene by this species followed by cycloalkylation of the aromatic ring. This is a cleaner approach to the synthesis of 2-tetralones compared to Friedel-Crafts aliphatic acylation-cycloalkylation in that use of thionyl chloride, aluminum trichloride, and a chlorinated hydrocarbon solvent is eliminated. In addition, the atom efficiency is augmented by recovery of the spent TFAA as trifluoroacetic acid (TFA) and conversion of this back to TFAA by dehydration.

  6. Theoretical evaluation of the efficiency of gas single-stage reciprocating compressor medium pressure units

    Science.gov (United States)

    Busarov, S. S.; Vasil'ev, V. K.; Busarov, I. S.; Titov, D. S.; Panin, Ju. N.

    2017-08-01

    Developed earlier and tested in such working fluid as air, the technology of calculating the operating processes of slow-speed long-stroke reciprocating stages let the authors to obtain successful results concerning compression of gases to medium pressures in one stage. In this connection, the question of the efficiency of the application of slow-speed long-stroke stages in various fields of technology and the national economy, where the working fluid is other gas or gas mixture, is topical. The article presents the results of the efficiency evaluation of single-stage compressor units on the basis of such stages for cases when ammonia, hydrogen, helium or propane-butane mixture is used as the working fluid.

  7. Isolated EWiRaC: A New Low-Stress Single-Stage Isolated PFC Converter

    DEFF Research Database (Denmark)

    Schneider, Henrik; Bergendorff, Stefan Pihl; Petersen, Lars

    2007-01-01

    A new PFC-family of Efficient Wide Range Converters named EWiRaC was recently introduced. EWiRaC has a major advantage in terms of efficiency at low-line and handles challenges like inrush current limiting as an integrated part of the conversion scheme. The main objective of this paper is to inve......A new PFC-family of Efficient Wide Range Converters named EWiRaC was recently introduced. EWiRaC has a major advantage in terms of efficiency at low-line and handles challenges like inrush current limiting as an integrated part of the conversion scheme. The main objective of this paper...... is to investigate the performance of an isolated EWiRaC (I-EWiRaC) in a single-stage PFC configuration....

  8. Realization of single-phase single-stage grid-connected PV system

    Directory of Open Access Journals (Sweden)

    Osama M. Arafa

    2017-05-01

    Full Text Available This paper presents a single phase single stage grid-tied PV system. Grid angle detection is introduced to allow operation at any arbitrary power factor but unity power factor is chosen to utilize the full inverter capacity. The system ensures MPPT using the incremental conductance method and it can track the changes in insolation level without oscillations. A PI voltage controller and a dead-beat current controller are used to ensure high quality injected current to the grid. The paper investigates the system structure and performance through numerical simulation using Matlab/Simulink. An experimental setup controlled by the MicrolabBox DSP prototyping platform is utilized to realize the system and study its performance. The precautions for smooth and safe system operation including the startup sequence are fully considered in the implementation.

  9. High efficiency 40 K single-stage Stirling-type pulse tube cryocooler

    Science.gov (United States)

    Wu, X. L.; Chen, L. B.; Pan, C. Z.; Cui, C.; Wang, J. J.; Zhou, Y.

    2017-12-01

    A high efficiency single-stage Stirling-type coaxial pulse tube cryocooler (SPTC) operating at around 40 K has been designed, built and tested. The double-inlet and the inertance tubes together with the gas reservoir were adopted as the phase shifters. Under the conditions of 2.5 MPa charging pressure and 30 Hz operating frequency, the prototype has achieved a no-load temperature of 23.8 K with 330 W of electric input power at a rejection temperature of 279 K. When the input power increases to 400 W, it can achieve a cooling capacity of 4.7 W/40 K while rejecting heat at 279 K yielding an efficiency of 7.02% relative to Carnot. It achieves a cooling capacity of 5 W/40 K with an input power of 450 W. It takes 10 minutes for the SPTC to cool to its no-load temperature of 40 K from 295 K.

  10. Self-Excited Single-Stage Power Factor Correction Driving Circuit for LED Lighting

    Directory of Open Access Journals (Sweden)

    Yong-Nong Chang

    2014-01-01

    Full Text Available This pa\tper proposes a self-excited single-stage high power factor LED lighting driving circuit. Being featured with power factor correction capability without needing any control devices, the proposed circuit structure is with low cost and suitable for commercial production. The power factor correction function is accomplished by using inductor in combination with a half-bridge quasi resonant converter to achieve active switching and yield out voltage regulation according to load requirement. Furthermore, the zero-voltage switching in the half-bridge converter can be attained to promote the overall performance efficiency of the proposed circuit. Finally, the validity and production availability of the proposed circuit will be verified as well.

  11. Detection of Brucella melitensis and Brucella abortus strains using a single-stage PCR method

    Directory of Open Access Journals (Sweden)

    Alamian, S.

    2015-04-01

    Full Text Available Brucella melitensis and Brucella abortus are of the most important causes of brucellosis, an infectious disease which is transmitted either directly or indirectly including consuming unpasteurized dairy products. Both strains are considered endemic in Iran. Common diagnostic methods such as bacteriologic cultures are difficult and time consuming regarding the bacteria. The aim of this study was to suggest a single-stage PCR method using a pair of primers to detect both B. melitensis and B. abortus. The primers were named UF1 and UR1 and the results showed that the final size of PCR products were 84 bp and 99 bp for B. melitensis and B. abortus, respectively. Therefore the method could be useful for rapid detection of B. melitensis and B. abortus simultaneously.

  12. Single stage to orbit mass budgets derived from propellant density and specific impulse

    Energy Technology Data Exchange (ETDEWEB)

    Whitehead, J.C.

    1996-06-06

    The trade between specific impulse (Isp) and density is examined in view of Single Stage To Orbit (SSTO) requirements. Mass allocations for vehicle hardware are derived from these two properties, for several propellant combinations and a dual-fuel case. This comparative analysis, based on flight-proven hardware, indicates that the higher density of several alternative propellants compensates for reduced Isp, when compared with cryogenic oxygen and hydrogen. Approximately half the orbiting mass of a rocket- propelled SSTO vehicle must be allocated to propulsion hardware and residuals. Using hydrogen as the only fuel requires a slightly greater fraction of orbiting mass for propulsion, because hydrogen engines and tanks are heavier than those for denser fuels. The advantage of burning both a dense fuel and hydrogen in succession depends strongly on tripropellant engine weight. The implications of the calculations for SSTO vehicle design are discussed, especially with regard to the necessity to minimize non-tankage structure.

  13. Single-stage management with combined tri-endoscopic approach for concomitant cholecystolithiasis and choledocholithiasis.

    Science.gov (United States)

    Lv, Fujing; Zhang, Shutian; Ji, Ming; Wang, Yongjun; Li, Peng; Han, Wei

    2016-12-01

    The aim of this study was to investigate the value of a single stage with combined tri-endoscopic (duodenoscopy, laparoscopy and choledochoscopy) approach for patients with concomitant cholecystolithiasis and choledocholithiasis. Fifty-three patients with combined gallbladder stones and common bile duct stones from February 2014 to April 2015 were randomized assigned to two groups: 29 patients underwent single-stage surgery with combined duodenoscope, laparoscope and choledochoscope (combined tri-endoscopic group), and 29 patients underwent endoscopic sphincterotomy to remove common bile duct stones followed by laparoscopic cholecystectomy several days later (control group). The success rate of complete stone removal, procedure-related complication, hospital stay and the cost of hospitalization were compared between the two groups. Altogether, 53 patients (29 patients in combined tri-endoscopic group and 24 patients in control group) successfully underwent the surgery and ERCP procedure. Three patients in the control group developed post-ERCP pancreatitis. One case of bile leaking and one case of residual stone were noted in the combined tri-endoscopic group. There were no significant differences between the two groups with regard to both complete stone removal [96.6 % (28/29) vs. 100 % (24/24)] and procedure-related complication rate [3.4 % (1/29) vs. 12.5 % (3/24)] (p > 0.05). No open surgery was required in either group. There were significant differences between the two groups with regard to hospital stay (6.72 ± 1.3 days vs. 10.91 ± 1.6 days, p choledocholithiasis was just as safe and successful as the control group. In addition, it resulted in a shorter hospital stay and less cost.

  14. Outcome of single stage vertebral column resection in treatment of kyphotic deformity.

    Science.gov (United States)

    Arif, Mohammad; Satar, Abdul; Saeed, Muhammad; Wazir, Zahid; Inam, Mohammad

    2014-12-01

    To find the frequency of deformity correction, functional outcome and complications of single-stage vertebral column resection in patients with kyphotic deformity. The prospective case series was conducted at Hayatabad Medical Complex, Peshawar, and Aman Hospital, Peshawar, from January 2012 to December 2013, and comprised all patients who underwent single-stage posterior vertebral column resection. Only patients with severe rigid sharp deformity of different aetiology that required more than 40 degree correction and who had at least 3-month follow-up were included. Data was processed using SPSS 16. Of the total 18 patients, 11(61.1%) were male and 7(38.9%) were female, with an overall mean age of 28.7±13.6 years (range: 12-60 years). Among them, 8(44.4%) patients had congenital kyphosis, 5(27.8%) had posttraumatic origin, 4(22.2%) had post-tuberculous deformity, while 1(5.6%) had iatrogenic kyphosis. The apex of the deformity was in thoracic spine in 12(66.7%) patients, while in 6(33.3%) patients it was in the lumbar spine. The average pre- and post-operative Cobb's angle was 66.2±18.9 degrees and 18.8±12.8 degrees respectively. Mean correction of deformities was 47.3±13.3 degrees. The mean correction achieved in percentage terms was 73.5±8.6 per cent (range: 56-87%). There were no patients with post-operative deterioration of neurological status. Two (11%) patients underwent re-exploration of the wounds with wash and cultures due to wound discharge. Posterior vertebral column resection was found to be a very effective method of correction of severe kyphotic deformities in expert hands with acceptable morbidity.

  15. Comparisons of single-stage and two-stage approaches to genomic selection.

    Science.gov (United States)

    Schulz-Streeck, Torben; Ogutu, Joseph O; Piepho, Hans-Peter

    2013-01-01

    Genomic selection (GS) is a method for predicting breeding values of plants or animals using many molecular markers that is commonly implemented in two stages. In plant breeding the first stage usually involves computation of adjusted means for genotypes which are then used to predict genomic breeding values in the second stage. We compared two classical stage-wise approaches, which either ignore or approximate correlations among the means by a diagonal matrix, and a new method, to a single-stage analysis for GS using ridge regression best linear unbiased prediction (RR-BLUP). The new stage-wise method rotates (orthogonalizes) the adjusted means from the first stage before submitting them to the second stage. This makes the errors approximately independently and identically normally distributed, which is a prerequisite for many procedures that are potentially useful for GS such as machine learning methods (e.g. boosting) and regularized regression methods (e.g. lasso). This is illustrated in this paper using componentwise boosting. The componentwise boosting method minimizes squared error loss using least squares and iteratively and automatically selects markers that are most predictive of genomic breeding values. Results are compared with those of RR-BLUP using fivefold cross-validation. The new stage-wise approach with rotated means was slightly more similar to the single-stage analysis than the classical two-stage approaches based on non-rotated means for two unbalanced datasets. This suggests that rotation is a worthwhile pre-processing step in GS for the two-stage approaches for unbalanced datasets. Moreover, the predictive accuracy of stage-wise RR-BLUP was higher (5.0-6.1%) than that of componentwise boosting.

  16. Study on trickle leaching of a high-grade uranium ore

    International Nuclear Information System (INIS)

    Lin Sirong; Gao Xizhen; Guo Erhua; Lu Shijie

    1996-01-01

    The trickle leaching process for a high-grade silicate uranium ore existing mainly as uraninite form has been studied. Two-stage counter-current trickle leaching with manganese dioxide as oxidant and ferric sulphate solution as leaching agent is used in the process. The leached solution which contains dissolved uranium and iron is carried back to the neutralizing stage and the iron is precipitated in this stage. The acid is added to the main stage and the precipitated iron is dissolved into Fe 2 (SO 4 ) 3 serving as lixiviant in the stage. Compared with conventional agitation acid leaching method, this process decreases the acid consumption by 21% and manganese dioxide by 29%, the extraction rate of uranium reduces by 1.86%

  17. Modelling of an adiabatic trickle-bed reactor with phase change

    DEFF Research Database (Denmark)

    Ramirez Castelan, Carlos Eduardo; Hidalgo-Vivas, Angelica; Brix, Jacob

    2017-01-01

    This paper describes a modelling approach of the behavior of trickle-bed reactors used for catalytic hydrotreating of oil fractions. A dynamic plug-flow heterogeneous one-dimensional adiabatic model was used to describe the main reactions present in the hydrotreating process: hydrodesulfurization......, hydrodenitrogenation, and hydrodearomatization. The model was solved using a finite differences scheme and was coupled with a flash calculation in ProII and thus, obtaining a simulation framework that can be generally used for such reactors....

  18. Design of an emi output filter for frequency converters

    NARCIS (Netherlands)

    Roc'h, A.; Bergsma, J.G.; Bergsma, H.; Leferink, Frank Bernardus Johannes; Zhao, D.; Polinder, H.; Ferreira, B.

    2006-01-01

    A filter has been designed to reduce conducted and radiated emission generated by a frequency converter. The frequency converter, cables and motor were modelled in order to make a good estimation of the radiated emission. A single stage output filter was designed making use of feedthrough apacitors

  19. Attainability and minimum energy of single-stage membrane and membrane/distillation hybrid processes

    KAUST Repository

    Alshehri, Ali

    2014-12-01

    As an energy-efficient separation method, membrane technology has attracted more and more attentions in many challenging separation processes. The attainability and the energy consumption of a membrane process are the two basic fundamental questions that need to be answered. This report aims to use process simulations to find: (1) at what conditions a single-stage membrane process can meet the separation task that is defined by product purity and recovery ratio and (2) what are the most important parameters that determine the energy consumption. To perform a certain separation task, it was found that both membrane selectivity and pressure ratio exhibit a minimum value that is defined only by product purity and recovery ratio. The membrane/distillation hybrid system was used to study the energy consumption. A shortcut method was developed to calculate the minimum practical separation energy (MPSE) of the membrane process and the distillation process. It was found that the MPSE of the hybrid system is only determined by the membrane selectivity and the applied transmembrane pressure ratio in three stages. At the first stage when selectivity is low, the membrane process is not competitive to the distillation process. Adding a membrane unit to a distillation tower will not help in reducing energy. At the second medium selectivity stage, the membrane/distillation hybrid system can help reduce the energy consumption, and the higher the membrane selectivity, the lower is the energy. The energy conservation is further improved as pressure ratio increases. At the third stage when both selectivity and pressure ratio are high, the hybrid system will change to a single-stage membrane unit and this change will cause significant reduction in energy consumption. The energy at this stage keeps decreasing with selectivity at slow rate, but slightly increases with pressure ratio. Overall, the higher the membrane selectivity, the more the energy is saved. Therefore, the two

  20. Outcomes of single-stage total arch replacement via clamshell incision

    Directory of Open Access Journals (Sweden)

    Ishizaka Toru

    2011-09-01

    Full Text Available Abstract Background Treatment of complex aortic pathologies involving the transverse arch with extensive involvement of the descending aorta remains a surgical challenge. Since clamshell incision provides superior exposure of the entire thoracic aorta, we evaluated the use of this technique for single-stage total arch replacement by arch vessel reconstruction. Methods The arch-first technique combined with clamshell incision was used in 38 cases of aneurysm and aortic disease in 2008 and 2009. Extensive total arch replacement was used with clamshell incision for reconstruction of arch vessels under deep hypothermic circulatory arrest. Results Overall 30-day mortality was 13%. The mean operating time was approximately 8 hours. Deep hypothermia resulted in mean CPB time exceeding 4.5 hours and mean duration of circulatory arrest was 25 minutes. The overall postoperative temporary and permanent neurologic dysfunction rates were 3% and 3% for elective and 3% and 0% for emergency surgery, respectively. All patients except the five who died in hospital were discharged without nursing care after an average post-operative hospital stay of 35 days. Conclusions The arch-first technique, combined with clamshell incision, provides expeditious replacement of the thoracic aorta with an acceptable duration of hypothermic circulatory arrest and minimizes the risk of retrograde atheroembolism by using antegrade perfusion.

  1. Solvent Carryover Characterization and Recovery for a 10-inch Single Stage Centrifugal Contactor

    International Nuclear Information System (INIS)

    Lentsch, R.D.; Stephens, A.B.; Leung, D.T.; Baffling, K.E.; Harmon, H.D.; Suggs, P.C.

    2006-01-01

    A test program has been performed to characterize the organic solvent carryover and recovery from centrifugal contactors in the Caustic-side Solvent Extraction (CSSX) process. CSSX is the baseline design for removing cesium from salt solutions for Department of Energy (DOE) Savannah River Site's Salt Waste Processing Facility. CSSX uses a custom solvent to extract cesium from the salt solution in a series of single stage centrifugal contactors. Meeting the Waste Acceptance Criteria at the Defense Waste Processing Facility and Saltstone, as well as plant economics, dictate that solvent loss should be kept to a minimum. Solvent droplet size distribution in the aqueous outlet streams of the CSSX contactors is of particular importance to the design of solvent recovery equipment. Because insufficient solvent droplet size data existed to form a basis for the recovery system design, DOE funded the CSSX Solvent Carryover Characterization and Recovery Test (SCCRT). This paper presents the droplet size distribution of solvent and concentration in the contactor aqueous outlet streams as a function of rotor speed, bottom plate type, and flow rate. It also presents the performance data of a prototype coalescer. (authors)

  2. Single-Stage Step up/down Driver for Permanent-Magnet Synchronous Machines

    Science.gov (United States)

    Chen, T. R.; Juan, Y. L.; Huang, C. Y.; Kuo, C. T.

    2017-11-01

    The two-stage circuit composed of a step up/down dc converter and a three-phase voltage source inverter is usually adopted as the electric vehicle’s motor driver. The conventional topology is more complicated. Additional power loss resulted from twice power conversion would also cause lower efficiency. A single-stage step up/down Permanent-Magnet Synchronous Motor driver for Brushless DC (BLDC) Motor is proposed in this study. The number components and circuit complexity are reduced. The low frequency six-step square-wave control is used to reduce the switching losses. In the proposed topology, only one active switch is gated with a high frequency PWM signal for adjusting the rotation speed. The rotor position signals are fed back to calculate the motor speed for digital close-loop control in a MCU. A 600W prototype circuit is constructed to drive a BLDC motor with rated speed 3000 rpm, and can control the speed of six sections.

  3. Single-stage Kanban system with deterioration failures and condition-based preventive maintenance

    International Nuclear Information System (INIS)

    Xanthopoulos, A.S.; Koulouriotis, D.E.; Botsaris, P.N.

    2015-01-01

    Despite the fact that the fields of pull type production control policies and condition-based preventive maintenance have much in common contextually, they have evolved independently up to now. In this investigation, an attempt is made to bridge the gap between these two branches of knowledge by introducing the single-stage Kanban system with deterioration failures and condition-based preventive maintenance. The formalism of continuous time Markov chains is used to model the system and expressions for eight performance metrics are derived. Two important, from a managerial perspective, constrained optimization problems for the proposed model are defined where the objective is the simultaneous optimization of the Kanban policy, the preventive maintenance policy and the inspection schedule under conflicting performance criteria. Multiple instances of each optimization problem are solved by means of the augmented Lagrangian genetic algorithm. The results from the optimization trials coupled by the results from extensive numerical examples facilitate the thorough investigation of the system’s behaviour. - Highlights: • Kanban system with deterioration failures and preventive maintenance is introduced. • The system is modeled as a continuous time Markov chain. • Expressions for eight performance metrics are derived. • The behavior of the system is studied through numerical examples. • Optimization results for selected performance metrics are presented

  4. Single stage: dorsolateral onlay buccal mucosal urethroplasty for long anterior urethral strictures using perineal route

    Directory of Open Access Journals (Sweden)

    Vikram Prabha

    2016-06-01

    Full Text Available ABSTRACT Objective To assess the outcome of single stage dorsolateral onlay buccal mucosal urethroplasty for long anterior urethral strictures (>4cm long using a perineal incision. Materials and Methods From August 2010 to August 2013, 20 patients underwent BMG urethroplasty. The cause of stricture was Lichen sclerosis in 12 cases (60%, Instrumentation in 5 cases (25%, and unknown in 3 cases (15%. Strictures were approached through a perineal skin incision and penis was invaginated into it to access the entire urethra. All the grafts were placed dorsolaterally, preserving the bulbospongiosus muscle, central tendon of perineum and one-sided attachement of corpus spongiosum. Procedure was considered to be failure if the patient required instrumentation postoperatively. Results Mean stricture length was 8.5cm (range 4 to 12cm. Mean follow-up was 22.7 months (range 12 to 36 months. Overall success rate was 85%. There were 3 failures (meatal stenosis in 1, proximal stricture in 1 and whole length recurrent stricture in 1. Other complications included wound infection, urethrocutaneous fistula, brownish discharge per urethra and scrotal oedema. Conclusion Dorsolateral buccal mucosal urethroplasty for long anterior urethral strictures using a single perineal incision is simple, safe and easily reproducible by urologists with a good outcome.

  5. [Achieve single-stage autotrophic biological nitrogen removal process by controlling the concentration of free ammonia].

    Science.gov (United States)

    Ji, Li-Li; Yang, Zhao-Hui; Xu, Zheng-Yong; Li, Xiao-Jiang; Tang, Zhi-Gang; Deng, Jiu-Hu

    2011-01-01

    Through controlling the concentration of free ammonia in the sequencing batch reactor (SBR), the single-stage autotrophic biological nitrogen removal process was achieved, including partial nitrification and anaerobic ammonium oxidation. The experiment was completed via two steps, the enrichment of nitrite bacteria and the inoculation of the mixture of anammox biomass. The operating temperature in the SBR was (31 +/- 2) degrees C. During the step of the enrichment of nitrite bacteria, pH was about 7.8. Changes of FA concentration were achieved by controlling the concentration of influent NH4(+) -N(56-446 mg x L(-1)), in order to inhibit and eliminate the nitrate bacteria. The activity tests of the sludge, 55d after enrichment, showed strong activity of aerobic ammonium oxidation [2.91 kg x (kg x d)(-1)] and low activity of nitrite oxidation [0.03 kg x(kg x d)(-1)]. During the inoculation of the mixture of anammox biomass, changes of FA concentration were achieved by controlling the concentration of influent NH4(+) -N and pH. As the inoculation of anammox biomass, abundant of bacteria and nutrient content were into the reactor and there kept high activity of aerobic ammonium oxidation [2.83 kg x (kg x d)(-1)] and a certain activity of nitrite oxidation, at the same time, the activity of anammox and heterotrophic denitrification reached 0.65 kg x (kg x d)(-1) and 0.11 kg x (kg x d)(-1), respectively.

  6. Wind-driven SEIG supplying DC microgrid through a single-stage power converter

    Directory of Open Access Journals (Sweden)

    Vellapatchi Nayanar

    2016-09-01

    Full Text Available Nowadays, there is an increased emphasis on utilizing the renewable energy sources and selection of suitable power converters for supplying dc microgrid. Among the various renewable energy sources, wind energy stands first in terms of installed capacity. So, an attempt is made in this paper for supplying dc microgrid utilizing wind energy. A self-excited induction generator has been used in the proposed wind energy conversion system (WECS. A single-stage power converter, namely, semi-converter is connected between the SEIG and dc grid terminals for closed-loop control of the proposed system. A perturb and observe (P&O based maximum power point tracking (MPPT algorithm has been developed and implemented using a dsPIC30F4011 digital controller. In this MPPT algorithm, the firing angle of the converter is adjusted by continuously monitoring the dc grid current for a given wind velocity. For analyzing the proposed system, a MATLAB/Simulink model has been developed by selecting the various components starting from wind-turbine model to the power converter supplying dc microgrid. Successful working of the proposed WECS has also been shown through experimental results obtained on a prototype model developed in the laboratory.

  7. Construction and characterization of a single stage dual diaphragm gas gun

    Science.gov (United States)

    Helminiak, Nathaniel Steven

    In the interest of studying the propagation of shock waves, this work sets out to design, construct, and characterize a pneumatic accelerator that performs high-velocity flyer plate impact tests. A single stage gas gun with a dual diaphragm breach allows for a non-volatile, reliable experimental testing platform for shock phenomena. This remotely operated gas gun utilizes compressed nitrogen to launch projectiles down a 14 foot long, 2 inch diameter bore barrel, which subsequently impacts a target material of interest. A dual diaphragm firing mechanism allows the 4.5 liter breech to reach a total pressure differential of 10ksi before accelerating projectiles to velocities as high as 1,000 m/s (1570-2240 mph). The projectile's velocity is measured using a series of break pin circuits. The target response can be measured with Photon Doppler Velocimetry (PDV) and/or stress gauge system. A vacuum system eliminates the need for pressure relief in front of the projectile, while additionally allowing the system to remain closed over the entire firing cycle. Characterization of the system will allow for projectile speed to be estimated prior to launching based on initial breach pressure.

  8. Orifice Mass Flow Calculation in NASA's W-8 Single Stage Axial Compressor Facility

    Science.gov (United States)

    Bozak, Richard F.

    2018-01-01

    Updates to the orifice mass flow calculation for the W-8 Single Stage Axial Compressor Facility at NASA Glenn Research Center are provided to include the effect of humidity and incorporate ISO 5167. A methodology for including the effect of humidity into the inlet orifice mass flow calculation is provided. Orifice mass flow calculations provided by ASME PTC-19.5-2004, ASME MFC-3M-2004, ASME Fluid Meters, and ISO 5167 are compared for W-8's atmospheric inlet orifice plate. Differences in expansion factor and discharge coefficient given by these standards give a variation of about +/- 75% mass flow except for a few cases. A comparison of the calculations with an inlet static pressure mass flow correlation and a fan exit mass flow integration using test data from a 2017 turbofan rotor test in W-8 show good agreement between the inlet static pressure mass flow correlation, ISO 5167, and ASME Fluid Meters. While W-8's atmospheric inlet orifice plate violates the pipe diameter limit defined by each of the standards, the ISO 5167 is chosen to be the primary orifice mass flow calculation to use in the W-8 facility.

  9. Single-stage transforaminal decompression, debridement, interbody fusion, and posterior instrumentation for lumbosacral brucellosis.

    Science.gov (United States)

    Abulizi, Yakefu; Liang, Wei-Dong; Muheremu, Aikeremujiang; Maimaiti, Maierdan; Sheng, Wei-Bin

    2017-07-14

    Spinal brucellosis is a less commonly reported infectious spinal pathology. There are few reports regarding the surgical treatment of spinal brucellosis in existing literature. This retrospective study was conducted to determine the effectiveness of single-stage transforaminal decompression, debridement, interbody fusion, and posterior instrumentation for lumbosacral spinal brucellosis. From February 2012 to April 2015, 32 consecutive patients (19 males and 13 females, mean age 53.7 ± 8.7) with lumbosacral brucellosis treated by transforaminal decompression, debridement, interbody fusion, and posterior instrumentation were enrolled. Medical records, imaging studies, laboratory data were collected and summarized. Surgical outcomes were evaluated based on visual analogue scale (VAS), Oswestry Disability Index (ODI) and Japanese Orthopaedic Association (JOA) scale. The changes in C-reactive protein (CRP) levels, erythrocyte sedimentation rate (ESR), clinical symptoms and complications were investigated. Graft fusion was evaluated using Bridwell grading criteria. The mean follow-up period was 24.9 ± 8.2 months. Back pain and radiating leg pain was relieved significantly in all patients after operation. No implant failures were observed in any patients. Wound infection was observed in two patients and sinus formation was observed in one patient. Solid bony fusion was achieved in 30 patients and the fusion rate was 93.8%. The levels of ESR and CRP were returned to normal by the end of three months' follow-up. VAS and ODI scores were significantly improved (P brucellosis.

  10. Multistage parallel-serial time averaging filters

    International Nuclear Information System (INIS)

    Theodosiou, G.E.

    1980-01-01

    Here, a new time averaging circuit design, the 'parallel filter' is presented, which can reduce the time jitter, introduced in time measurements using counters of large dimensions. This parallel filter could be considered as a single stage unit circuit which can be repeated an arbitrary number of times in series, thus providing a parallel-serial filter type as a result. The main advantages of such a filter over a serial one are much less electronic gate jitter and time delay for the same amount of total time uncertainty reduction. (orig.)

  11. Correlation of precursor and product ions in single-stage high resolution mass spectrometry. A tool for detecting diagnostic ions and improving the precursor elemental composition elucidation

    Energy Technology Data Exchange (ETDEWEB)

    Borràs, S. [Departament de Química Analítica, Universitat de Barcelona, Martí i Franquès 1-11, 08028 Barcelona (Spain); Kaufmann, A., E-mail: anton.kaufmann@klzh.ch [Official Food Control Authority, Fehrenstrasse 15, 8032 Zürich (Switzerland); Companyó, R. [Departament de Química Analítica, Universitat de Barcelona, Martí i Franquès 1-11, 08028 Barcelona (Spain)

    2013-04-15

    Highlights: ► We are describing a technique to spot ions which are derived from each other. ► Single stage high resolution data is used. ► This “in silicon” technique is compared to conventional precursor scan. ► Some applications for this technique are presented. -- Abstract: Monitoring of common diagnostic fragments is essential for recognizing molecules which are members of a particular compound class. Up to now, unit resolving tandem quadrupole mass spectrometers, operating in the precursor ion scan mode, have been typically used to perform such analysis. By means of high-resolution mass spectrometry (HRMS) a much more sensitive and selective detection can be achieved. However, using a single-stage HRMS instrument, there is no unequivocal link to the corresponding precursor ion, since such instrumentation does not permit a previous precursor selection. Thus, to address this limitation, an in silico approach to locate precursor ions, based on diagnostic fragments, was developed. Implemented as an Excel macro, the algorithm rapidly assembles and surveys exact mass data to provide a list of feasible precursor candidates according to the correlation of the chromatographic peak shape profile and other additional filtering criteria (e.g. neutral losses and isotopes). The macro was tested with two families of veterinary drugs, sulfonamides and penicillins, which are known to yield diagnostic product ions when fragmented. Data sets obtained from different food matrices (fish and liver), both at high and low concentration of the target compounds, were investigated in order to evaluate the capabilities and limitations of the reported approach. Finally, other possible applications of this technique, such as the elucidation of elemental compositions based on product ions and corresponding neutral losses, were also presented and discussed.

  12. Kinetics of the removal of mono-chlorobenzene vapour from waste gases using a trickle bed air biofilter.

    Science.gov (United States)

    Mathur, Anil K; Sundaramurthy, J; Balomajumder, C

    2006-10-11

    The performance of a trickle bed air biofilter (TBAB) in the removal of mono-chlorobenzene (MCB) was evaluated in concentrations varying from 0.133 to 7.187 g m(-3) and at empty bed residence time (EBRT) varying from 37.7 to 188.52 s. More than 90% removal efficiency in the trickle bed air biofilter was achieved for the inlet MCB concentration up to 1.069 g m(-3) and EBRT less than 94.26 s. The trickle bed air biofilter was constructed with coal packing material, inoculated with a mixed consortium of activated sludge obtained from sewage treatment plant. The continuous performance of the removal of MCB in the trickle bed air biofilter was monitored for various gas concentrations, gas flow rates, and empty bed residence time. The experiment was conducted for a period of 75 days. The trickle bed air biofilter degrading MCB with an average elimination capacity of 80 g m(-3) h(-1) was obtained. The effect of starvation was also studied. After starvation period of 8 days, the degradation was low but recovered within a short period of time. Using macrokinetic determination method, the Michaelis-Menten kinetic constant K(m) and maximum reaction rate, r(max) evaluated as 0.121 g m(-3) s(-1) and 7.45 g m(-3), respectively.

  13. Evaluation of single-stage adjustable strabismus surgery under conscious sedation

    Directory of Open Access Journals (Sweden)

    Sharma Pradeep

    2009-01-01

    Full Text Available Purpose: To evaluate the feasibility and stability of ocular alignment after single-stage adjustable strabismus surgery (SSASS performed under topical anesthesia. Materials and Methods: Forty-five patients of concomitant exodeviations were randomized into three groups of 15 cases each and were operated with three different techniques: Group I - conventional surgery, Group II - two-stage adjustable suture technique with suture adjustment performed 6h postoperatively and Group III- SSASS under topical anesthesia and intravenous conscious sedation with midazolam and fentanyl. Intraoperative suture adjustment was done by giving a cross target to the patient on the ceiling at the end of the procedure. Surgical results were compared among the three groups at three months follow-up. Intraoperative hemodynamic parameters and patients′ experience of the surgery (by questionnaire were also compared. Results: Mean preoperative deviation for distance in Groups I, II, III was -41.67 prism diopter (pd ±9.0, -38.93 pd ±11.05 and -41.87 pd ±8.91 ( P =0.6 respectively. At three months, mean correction achieved for distance was +31.87 pd ±11.71, +35.47 pd ±10.86 and +42.80 pd ±10.71 respectively which was significantly different between Group III and Group I ( P =0.03. Intraoperatively all hemodynamic parameters remained stable and comparable ( P =0. 5 in all groups. Intraoperative pain ( P < 0.001 and time taken for surgery ( P < 0.001 was more in the SSASS group. Amount of exodrift was 10-12 pd, comparable in all three groups ( P = 0.5. Conclusions: SSASS, performed under topical anesthesia, is safe and has better outcomes than conventional recession-resection surgery for concomitant exodeviation. An overcorrection of about 10-12 pd is recommended to check the exodrift and achieve stable alignment.

  14. Metoidioplasty as a single stage sex reassignment surgery in female transsexuals: Belgrade experience.

    Science.gov (United States)

    Djordjevic, Miroslav L; Stanojevic, Dusan; Bizic, Marta; Kojovic, Vladimir; Majstorovic, Marko; Vujovic, Svetlana; Milosevic, Alexandar; Korac, Gradimir; Perovic, Sava V

    2009-05-01

    Metoidioplasty represents one of the variants of phalloplasty in female transsexuals. Its main characteristic is that it is a one-stage procedure. It involves lengthening and straightening of hypertrophied clitoris to create a neophallus, urethral lengthening to enable voiding while standing, and scrotal reconstruction with insertion of testicle prostheses. Our aim is to describe our technique and highlight its advantages. Between September 2002 and April 2007, 82 female transsexuals, aged 18-54 years (mean age 31) underwent one-stage metoidioplasty. Clitoris is lengthened and straightened by division of clitoral ligaments and short urethral plate. Urethroplasty is done with combined buccal mucosa graft and genital skin flaps. Scrotum is created from labia majora in which two testicle prostheses are inserted. Simultaneously, female genitalia are removed. Patients' personal satisfaction about sensitivity and length of neophallus, possibility to void in standing position, real length of reconstructed urethra as well as complication rate comparing to other published data. The median follow-up was 32 months (range 14-69). The mean neophallic length was 5.7 cm (range 4-10). Voiding in standing position was reported in all patients, while dribbling and spraying were noticed in 23 cases and solved spontaneously. There were two urethral strictures and seven fistulas that required secondary minor revision. All patients reported preserved sensation and normal postoperative erection. Testicle prostheses rejection was not observed in any of the patients. Metoidioplasty is a single-stage and time-saving procedure. It could be an alternative to total phalloplasty in female transsexuals who do not wish to have sexual intercourse. Also, it represents a first step in cases where additional augmentation phalloplasty is required.

  15. Thermodynamic simulation of condensation heat recovery characteristics of a single stage centrifugal chiller in a hotel

    International Nuclear Information System (INIS)

    Gong, Guangcai; Chen, Feihu; Su, Huan; Zhou, Jianyong

    2012-01-01

    Highlights: ► Thermodynamic model of a two-condenser condensation system has been carried out. ► Dynamic simulation method has been presented. ► COP and g of the refrigerating system is better than the single condensation system. ► The optimal parameters for the two-condenser condensation system have been studied. -- Abstract: A thermodynamic simulation study has been carried out for a single stage centrifugal chiller in this paper. The cooling capacity of the chiller unit is about 1750 kW. The chiller unit has been set and tested, and the work refrigerant is R22. A heat exchanger has been set between outlet of the compressor and the condenser for sanitary hot water supplying. Then the chiller unit is a kind of combined system that can provide sanitary hot water supplying and air conditioning simultaneously. A thermodynamic simulation model of the combined system has been established with the system simulation toolbox Simulink. Performance of the components and the combined system of the chiller unit has been studied over a wide range of operating conditions. The potential energy and fuel cost saving associated with the use of the proposed combined system for a typical hotel in south China has been estimated. It is showed that the combined system of the chiller unit is very useful in hotel buildings. And the thermodynamic simulation model of the combined system is significance for the optimization of parameters of the chiller unit such as condensation and evaporation temperature, mass flow of the sanitary hot water and size of hot water storage tank.

  16. An operation protocol for facilitating start-up of single-stage autotrophic nitrogen removing reactors based on process stoichiometry

    DEFF Research Database (Denmark)

    Mutlu, A. Gizem; Vangsgaard, Anna Katrine; Sin, Gürkan

    2012-01-01

    Start-up and operation of single-stage nitritation/anammox reactor employing complete autotrophic nitrogen can be difficult. Keeping the performance criteria and monitoring the microbial community composition may not be easy or fast enough to take action on time. In this study, a control strategy...

  17. Low voltage ride-through capability control for single-stage inverter-based grid-connected photovoltaic power plant

    DEFF Research Database (Denmark)

    Al-Shetwi, Ali Q.; Sujod, Muhamad Zahim; Blaabjerg, Frede

    2018-01-01

    The low voltage ride-through (LVRT) capability is one of the challenges faced by the integration of large-scale photovoltaic (PV) power stations into electrical grid which has not been fully investigated. Therefore, this paper presents a comprehensive control strategy of single-stage PV power pla...

  18. Revision Anterior Cruciate Ligament Reconstruction: Results of a Single-stage Approach Using Allograft Dowel Bone Grafting for Femoral Defects.

    Science.gov (United States)

    Werner, Brian C; Gilmore, Carl J; Hamann, Joshua C; Gaskin, Cree M; Carroll, John J; Hart, Joseph M; Miller, Mark D

    2016-08-01

    The purpose of this study was to present results of single-stage revision anterior cruciate ligament (ACL) reconstruction using an allograft bone dowel for isolated femoral bony deficiency. Sixteen patients underwent single-stage revision ACL reconstruction using an allograft bone dowel for isolated femoral bony deficiency between 2007 and 2012. Twelve patients (75%) completed study visits, which included CT scans as well as completion of validated outcomes measures. The average KT-1000 side-to-side difference was 1.0 mm ± 2.9 mm. The average International Knee Documentation Committee score was 70.2 ± 17.8, the Tegner score was 4.8 ± 2.8, and the visual analog scale pain score was 2.8 ± 2.4. An analysis of CT scans showed that all 12 dowels had excellent (>75%) incorporation. A single-stage approach for revision ACL reconstruction using allograft dowels for isolated femoral bony deficiency yields objective and subjective outcomes comparable to those reported in the literature for two-stage and other single-stage techniques, with good incorporation of the dowels. Retrospective case series, level IV.

  19. Two-stage IMZ implants and ITI implants inserted in a single-stage procedure : A prospective comparative study

    NARCIS (Netherlands)

    Heydenrijk, Kees; Raghoebar, Gerry M.; Meijer, Henny J.A.; Reijden, Willy A. van der; Winkelhoff, Arie Jan van; Stegenga, Boudewijn

    2002-01-01

    The aim of this study was to evaluate the feasibility of using a two-stage implant system in a single-stage procedure and to study the impact of the microgap at crestal level and to monitor the microflora in the peri-implant area. Forty edentulous patients (Cawood & Howell class V–VI) participated

  20. Two-stage IMZ implants and ITI implants inserted in a single-stage procedure - A prospective comparative study

    NARCIS (Netherlands)

    Heydenrijk, K; Raghoebar, GM; Meijer, HJA; van der Reijden, WA; van Winkelhoff, AJ; Stegenga, B

    The aim of this study was to evaluate the feasibility of using a two-stage implant system in a single-stage procedure and to study the impact of the microgap at crestal level and to monitor the microflora in the peri-implant area. Forty edentulous patients (Cawood & Howell class V-VI) participated

  1. The Behavior of Pilot Trickle-Bed Reactor under Periodic Operation

    Czech Academy of Sciences Publication Activity Database

    Tukač, V.; Šimíčková, M.; Chyba, V.; Lederer, J.; Kolena, J.; Hanika, Jiří; Jiřičný, Vladimír; Staněk, Vladimír; Stavárek, Petr

    2007-01-01

    Roč. 62, 18-20 (2007), s. 4891-4895 ISSN 0009-2509. [International Symposium on Chemical Reaction Engineering - From Science to Innovative Engineering /19./. Potsdam/Berlin, 03.09.2006-06.09.2006] R&D Projects: GA MPO(CZ) FT-TA/039 Grant - others:CYCLOP(XE) G1RD/CT2000/00225 Institutional research plan: CEZ:AV0Z40720504 Source of funding: R - rámcový projekt EK Keywords : olefine hydrogenation * pilot-scale * trickle-bed reactor Subject RIV: CI - Industrial Chemistry, Chemical Engineering Impact factor: 1.775, year: 2007

  2. Fruit size, mineral composition and quality of trickle-irrigated tomatoes as affected by potassium rates.

    OpenAIRE

    FONTES, P.C.R.; SAMPAIO, R.A.; FINGER, F.L.

    2000-01-01

    An experiment was conducted to determine the fruit size, mineral composition and quality of trickle-irrigated tomatoes as affected by potassium fertilizer rates. Six potassium (K) rates were applied as KCl, corresponding to 0, 48.4, 118.6, 188.8, 259.0 and 399.4 kg ha-1, with four replicates, following a randomized block design. Quadratic responses to K rates were observed for double extra large (diameter > 60 mm), extra large (56 to 60 mm) and large (52 to 56 mm) fruit yields. Maximum yields...

  3. Experimental study of the application of two trickle media for inlet air pre-cooling of natural draft dry cooling towers

    International Nuclear Information System (INIS)

    He, Suoying; Guan, Zhiqiang; Gurgenci, Hal; Hooman, Kamel; Lu, Yuanshen; Alkhedhair, Abdullah M.

    2015-01-01

    Highlights: • Two trickle media were experimentally studied in a low-speed wind tunnel. • Correlations for cooling efficiency and pressure drop were developed. • Both trickle media were proven to have relatively low pressure drops. • Both trickle media had severe water entrainment at large air velocities. - Abstract: This paper is part two of a broader investigation into pre-cooling the air that enters natural draft dry cooling towers. Evaporative cooling of air is to some extent different from evaporative cooling of water. Two trickle media (Trickle125 and Trickle100) originally designed for evaporative cooling of water were studied in an open-circuit wind tunnel for evaporative cooling of air. Three medium thicknesses (200, 300 and 450 mm) and two water flow rates (10 and 5 l/min per m 2 horizontally exposed surface area) were used in the tests. The air velocities ranged from 0.5 to 3.0 m/s. The cooling efficiency and the pressure drop of the two media were curve fitted to yield a set of correlations. The pressure drop ranges for Trickle125 and Trickle100 were 0.7–50 Pa and 0.6–41.6 Pa, respectively. The cooling efficiencies of Trickle125 and Trickle100 fell within 15.7–55.1% and 11–44.4%, respectively. Generally, media with large effective surfaces provide high cooling efficiencies and high pressure drops; there is a trade-off between cooling efficiency and pressure drop when selecting a particular medium for a specific application. The water entrainment off the media was detected with water-sensitive papers, and both media had severe water entrainment at large air velocities

  4. Distribution and rate of microbial processes in ammonia-loaded air filter biofilm

    DEFF Research Database (Denmark)

    Juhler, Susanne; Nielsen, Lars Peter; Schramm, Andreas

    2009-01-01

    The in situ activity and distribution of heterotrophic and nitrifying bacteria and their potential interactions were investigated in a full-scale, two-section, trickling filter designed for biological degradation of volatile organics and NH3 in ventilation air from pig farms. The filter biofilm w...... with heterotrophic bacteria for O2 and inhibition by the protonated form of NO2-, HNO2. Product inhibition of AOB growth could explain why this type of filter tends to emit air with a rather constant NH3 concentration irrespective of variations in inlet concentration and airflow....

  5. Trickle-down boundary conditions in aeolian dune-field pattern formation

    Science.gov (United States)

    Ewing, R. C.; Kocurek, G.

    2015-12-01

    One the one hand, wind-blown dune-field patterns emerge within the overarching boundary conditions of climate, tectonics and eustasy implying the presence of these signals in the aeolian geomorphic and stratigraphic record. On the other hand, dune-field patterns are a poster-child of self-organization, in which autogenic processes give rise to patterned landscapes despite remarkable differences in the geologic setting (i.e., Earth, Mars and Titan). How important are climate, tectonics and eustasy in aeolian dune field pattern formation? Here we develop the hypothesis that, in terms of pattern development, dune fields evolve largely independent of the direct influence of 'system-scale' boundary conditions, such as climate, tectonics and eustasy. Rather, these boundary conditions set the stage for smaller-scale, faster-evolving 'event-scale' boundary conditions. This 'trickle-down' effect, in which system-scale boundary conditions indirectly influence the event scale boundary conditions provides the uniqueness and richness of dune-field patterned landscapes. The trickle-down effect means that the architecture of the stratigraphic record of dune-field pattern formation archives boundary conditions, which are spatially and temporally removed from the overarching geologic setting. In contrast, the presence of an aeolian stratigraphic record itself, reflects changes in system-scale boundary conditions that drive accumulation and preservation of aeolian strata.

  6. Extraction metallurgy for coarse particle ore and acid-curing and ferric-trickle leaching process

    International Nuclear Information System (INIS)

    Jin Suoqing

    1993-02-01

    Based on the viewpoint that only if the ground fine ore leaching method is replaced by the extraction from coarse particle ore, the face of uranium ore processing can be changed, the article presents the summary of the studying of thin-layer leaching (TLL) and of the developing a new process, acid-curing and ferric-trickle leaching (AFL) process (It is called NGJ process in China.). The operation of AFL process is similar to TLL method, but the water or acidified water is replaced by ferric solution for leaching-rising for cured ore. Ferric-trickle leaching can effectively complete the leaching reaction for uranium mineral in 'remaining leaching reaction' that is hardly to be finished in the course of curing. For the most uranium ores in China the AFL-process is competitive with the conventional leaching process. According to this analysis the AFL-process and other extractive processes for coarse particle should become basic extraction process for uranium ore in China. In other words the ore grinding is no more as an essential operation in uranium ore processing in China. Thus, many serious problems caused by ore grinding method in uranium ore processing can be solved and the uranium ore hydrometallurgy will be significantly changed

  7. Effects of Stator Shroud Injection on the Aerodynamic Performance of a Single-Stage Transonic Axial Compressor

    International Nuclear Information System (INIS)

    Dinh, Cong-Truong; Ma, Sang-Bum; Kim, Kwang Yong

    2017-01-01

    In this study, stator shroud injection in a single-stage transonic axial compressor is proposed. A parametric study of the effect of stator shroud injection on aerodynamic performances was conducted using the three-dimensional Reynolds-averaged Navier-Stokes equations. The curvature, length, width, and circumferential angle of the stator shroud injector and the air injection mass flow rate were selected as the test parameters. The results of the parametric study show that the aerodynamic performances of the single-stage transonic axial compressor were improved by stator shroud injection. The aerodynamic performances were the most sensitive to the injection mass flow rate. Further, the total pressure ratio and adiabatic efficiency were the maximum when the ratio of circumferential angle was 10%.

  8. Effects of Stator Shroud Injection on the Aerodynamic Performance of a Single-Stage Transonic Axial Compressor

    Energy Technology Data Exchange (ETDEWEB)

    Dinh, Cong-Truong; Ma, Sang-Bum; Kim, Kwang Yong [Inha Univ., Incheon (Korea, Republic of)

    2017-01-15

    In this study, stator shroud injection in a single-stage transonic axial compressor is proposed. A parametric study of the effect of stator shroud injection on aerodynamic performances was conducted using the three-dimensional Reynolds-averaged Navier-Stokes equations. The curvature, length, width, and circumferential angle of the stator shroud injector and the air injection mass flow rate were selected as the test parameters. The results of the parametric study show that the aerodynamic performances of the single-stage transonic axial compressor were improved by stator shroud injection. The aerodynamic performances were the most sensitive to the injection mass flow rate. Further, the total pressure ratio and adiabatic efficiency were the maximum when the ratio of circumferential angle was 10%.

  9. Area G perimeter surface-soil and single-stage water sampling: Environmental surveillance for fiscal year 95. Progress report

    Energy Technology Data Exchange (ETDEWEB)

    Childs, M.; Conrad, R.

    1997-09-01

    ESH-19 personnel collected soil and single-stage water samples around the perimeter of Area G at Los Alamos National Laboratory (LANL) during FY 95 to characterize possible radionuclide movement out of Area G through surface water and entrained sediment runoff. Soil samples were analyzed for tritium, total uranium, isotopic plutonium, americium-241, and cesium-137. The single-stage water samples were analyzed for tritium and plutonium isotopes. All radiochemical data was compared with analogous samples collected during FY 93 and 94 and reported in LA-12986 and LA-13165-PR. Six surface soils were also submitted for metal analyses. These data were included with similar data generated for soil samples collected during FY 94 and compared with metals in background samples collected at the Area G expansion area.

  10. Modeling of DNA single stage splicing language via Yusof-Goode approach: One string with two rules

    Science.gov (United States)

    Lim, Wen Li; Yusof, Yuhani; Mudaber, Mohammad Hassan

    2015-02-01

    Splicing system plays a pivotal role in attempts to recombine sets of double-stranded DNA molecules when acted by restriction enzymes and ligase. Traditional method of finding the result of DNA recombination through experiment is both time and money consuming. Hence, finding the number of patterns of DNA single stage splicing language through formalism of splicing system is a way to optimize the searching process. From the biological perspective, it predicts the number of types of molecules that will exist in the system under existence of restriction enzymes and ligase. In this paper, some theorems, corollaries and examples that lead to the predictions of single stage splicing languages involving one pattern string and two rules are presented via Yusof-Goode approach.

  11. Comparison of single-stage and temperature-phased two-stage anaerobic digestion of oily food waste

    International Nuclear Information System (INIS)

    Wu, Li-Jie; Kobayashi, Takuro; Li, Yu-You; Xu, Kai-Qin

    2015-01-01

    Highlights: • A single-stage and two two-stage anaerobic systems were synchronously operated. • Similar methane production 0.44 L/g VS added from oily food waste was achieved. • The first stage of the two-stage process became inefficient due to serious pH drop. • Recycle favored the hythan production in the two-stage digestion. • The conversion of unsaturated fatty acids was enhanced by recycle introduction. - Abstract: Anaerobic digestion is an effective technology to recover energy from oily food waste. A single-stage system and temperature-phased two-stage systems with and without recycle for anaerobic digestion of oily food waste were constructed to compare the operation performances. The synchronous operation indicated the similar ability to produce methane in the three systems, with a methane yield of 0.44 L/g VS added . The pH drop to less than 4.0 in the first stage of two-stage system without recycle resulted in poor hydrolysis, and methane or hydrogen was not produced in this stage. Alkalinity supplement from the second stage of two-stage system with recycle improved pH in the first stage to 5.4. Consequently, 35.3% of the particulate COD in the influent was reduced in the first stage of two-stage system with recycle according to a COD mass balance, and hydrogen was produced with a percentage of 31.7%, accordingly. Similar solids and organic matter were removed in the single-stage system and two-stage system without recycle. More lipid degradation and the conversion of long-chain fatty acids were achieved in the single-stage system. Recycling was proved to be effective in promoting the conversion of unsaturated long-chain fatty acids into saturated fatty acids in the two-stage system.

  12. Single stage incubators and Hypercapnia during incubation affect the vascularization of the chorioallantoic membrane in broiler embryos.

    Science.gov (United States)

    Fernandes, J I M; Bortoluzzi, C; Schmidt, J M; Scapini, L B; Santos, T C; Murakami, A E

    2017-01-01

    Incubation management can have direct effects on neonate health and consequently affect post-hatching development. The effects of incubation in multiple and single stage incubators with different concentrations of CO 2 were evaluated in terms of the vessel density in the chorioallantoic membrane, hatching, heart morphology, and body development of the neonate up to the tenth day. A total of 2,520 fertile eggs were used and distributed in a completely randomized design with 4 levels of CO 2 in 4 single-stage incubators (4,000; 6,000; 8,000; and 10,000 ppm) and a control treatment based on multiple-stage incubation, totaling 5 treatments. The levels of CO 2 were used during the first 10 d of the incubation period, and after this period, all eggs were submitted to the same level of CO 2 (4,000 ppm). Eggs that were incubated in multiple-stage incubators presented a lower percentage of vessels in the chorioallantoic membrane, lower yolk absorption by the embryo, wall depth of the right ventricle, and greater humidity losses in the eggs when compared to eggs in the single-stage incubators. The eggs submitted to hypercapnia, between 5,000 and 6,000 ppm of CO 2 , had a higher percentage of vessels in the chorioallantoic membrane; the embryos originating from these eggs had higher weight, with higher relative weight of the liver. However, the same levels reduced the yolk absorption. Single-stage incubation with moderate levels of hypercapnia is an efficient tool to be adopted by the hatcheries when attempting to improve chick quality. © 2016 Poultry Science Association Inc.

  13. Performance analysis of a single stage four bed metal hydride cooling system, part A: Influence of mass recovery

    Energy Technology Data Exchange (ETDEWEB)

    Abraham, Kevin; Prakash Maiya, M.; Srinivasa Murthy, S. [Refrigeration and Air-conditioning Laboratory, Department of Mechanical Engineering, Indian Institute of Technology Madras, 600036, Chennai (India)

    2003-01-01

    The concept of mass recovery in metal hydride systems is studied with a single stage multi-bed cooling system as example. Mass recovery results in variation of bed temperatures due to removal or addition of heat of desorption or absorption respectively. Coefficient of performance and cold output increase while required heat input decreases for the mass recovery cycle. Thus mass recovery between hydride reactors is found to improve system performance compared to that of a basic system. (authors)

  14. Theoretical comparison of single-stage and advanced absorption heat transformers used to increase solar pond's temperature

    Energy Technology Data Exchange (ETDEWEB)

    Rivera, W; Best, Roberto [Centro de Investigacion en Energia-UNAM, Temixco, Morelos (Mexico)

    2000-07-01

    Mathematical models of single-stage and advanced absorption heat transformers operating with the water/Carrol{sup T}M mixture were developed to simulate the performance of these systems coupled to a solar pond in order to increase the temperature of the useful heat produced by solar ponds. The results showed that the single-stage and the double absorption heat transformer are the most promising configuration to be coupled to solar ponds. With single-stage heat transformers it is possible to increase solar pond's temperature until 50 Celsius degrees with coefficients of performance of about 0.48 and with double absorption heat transformers until 100 Celsius degrees with coefficients of performance of 0.33. [Spanish] Se desarrollaron modelos matematicos de una sola etapa y transformadores avanzados de absorcion de calor operando con la mezcla agua/Carrol{sup T}M para simular el rendimiento de estos sistemas acoplados a un estanque solar con el objeto de aumentar la temperatura del calor util producido por los estanques solares. Los resultados mostraron que la etapa sencilla y el transformador de calor de absorcion doble son la configuracion mas prometedora para ser acoplado a estanques solares. Con los transformadores de calor de una sola etapa es posible aumentar la temperatura del estanque solar hasta 50 grados Celsius con coeficientes de rendimiento de alrededor de 0.48 y con transformadores de calor de doble absorcion hasta 100 grados Celsius con coeficientes de rendimiento de 0.33.

  15. How can recovery be enhanced after single-stage laparoscopic management of CBD stones? Endoscopic treatment versus laparoscopic surgery.

    Science.gov (United States)

    Chapuis-Roux, Emilie; Pellissier, Laurent; Browet, Francois; Berthou, Jean Charles; Hakim, Sami; Brazier, Franck; Cosse, Cyril; Delcenserie, Richard; Regimbeau, Jean Marc

    2017-07-01

    Single-stage management of CBD stones comprises simultaneous common bile duct (CBD) clearance and cholecystectomy. The CBD can be cleared by using endoscopic treatment (ET) or laparoscopic surgery (LS) alone. To determine the most rapid recovery after the single-stage laparoscopic management of CBD stones. Patients with CBD stones treated at either of two centers (one performing ET only and one performing LS only for single-stage treatment) were included. The primary endpoint was "the textbook outcome". The feasibility rate was 74% for ET and 100% for LS (p≤0.001). The proportion of cases with the textbook outcome was higher in the ET group than in the LS-only group (73% vs. 10%; pCBD clearance rate was similar in the ET and LS-only groups (100% vs. 96.6%, respectively; p=0.17). The overall morbidity rate was lower in the ET group than in the LS-only group (23% vs. 29%, p=0.05). Both ET and LS are feasible, safe and effective for clearance of the CBD. ET was better than LS in terms of a less frequent requirement for drainage and a shorter length of hospital stay. LS was associated with a shorter operating time. Copyright © 2017 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  16. A model for a countercurrent gas—solid—solid trickle flow reactor for equilibrium reactions. The methanol synthesis

    NARCIS (Netherlands)

    Westerterp, K.R.; Kuczynski, M.

    1987-01-01

    The theoretical background for a novel, countercurrent gas—solid—solid trickle flow reactor for equilibrium gas reactions is presented. A one-dimensional, steady-state reactor model is developed. The influence of the various process parameters on the reactor performance is discussed. The physical

  17. Integrated detoxification methodology of hazardous phenolic wastewaters in environmentally based trickle-bed reactors: Experimental investigation and CFD simulation

    Energy Technology Data Exchange (ETDEWEB)

    Lopes, Rodrigo J.G., E-mail: rodrigo@eq.uc.pt [Centro de Investigacao em Engenharia dos Processos Quimicos e Produtos da Floresta (CIEPQPF), GERSE - Group on Environmental, Reaction and Separation Engineering, Department of Chemical Engineering, University of Coimbra, Rua Silvio Lima, Polo II - Pinhal de Marrocos, 3030-790 Coimbra (Portugal); Almeida, Teresa S.A.; Quinta-Ferreira, Rosa M. [Centro de Investigacao em Engenharia dos Processos Quimicos e Produtos da Floresta (CIEPQPF), GERSE - Group on Environmental, Reaction and Separation Engineering, Department of Chemical Engineering, University of Coimbra, Rua Silvio Lima, Polo II - Pinhal de Marrocos, 3030-790 Coimbra (Portugal)

    2011-05-15

    Centralized environmental regulations require the use of efficient detoxification technologies for the secure disposal of hazardous wastewaters. Guided by federal directives, existing plants need reengineering activities and careful analysis to improve their overall effectiveness and to become environmentally friendly. Here, we illustrate the application of an integrated methodology which encompasses the experimental investigation of catalytic wet air oxidation and CFD simulation of trickle-bed reactors. As long as trickle-bed reactors are determined by the flow environment coupled with chemical kinetics, first, on the optimization of prominent numerical solution parameters, the CFD model was validated with experimental data taken from a trickle bed pilot plant specifically designed for the catalytic wet oxidation of phenolic wastewaters. Second, several experimental and computational runs were carried out under unsteady-state operation to evaluate the dynamic performance addressing the TOC concentration and temperature profiles. CFD computations of total organic carbon conversion were found to agree better with experimental data at lower temperatures. Finally, the comparison of test data with simulation results demonstrated that this integrated framework was able to describe the mineralization of organic matter in trickle beds and the validated consequence model can be exploited to promote cleaner remediation technologies of contaminated waters.

  18. Integrated detoxification methodology of hazardous phenolic wastewaters in environmentally based trickle-bed reactors: Experimental investigation and CFD simulation

    International Nuclear Information System (INIS)

    Lopes, Rodrigo J.G.; Almeida, Teresa S.A.; Quinta-Ferreira, Rosa M.

    2011-01-01

    Centralized environmental regulations require the use of efficient detoxification technologies for the secure disposal of hazardous wastewaters. Guided by federal directives, existing plants need reengineering activities and careful analysis to improve their overall effectiveness and to become environmentally friendly. Here, we illustrate the application of an integrated methodology which encompasses the experimental investigation of catalytic wet air oxidation and CFD simulation of trickle-bed reactors. As long as trickle-bed reactors are determined by the flow environment coupled with chemical kinetics, first, on the optimization of prominent numerical solution parameters, the CFD model was validated with experimental data taken from a trickle bed pilot plant specifically designed for the catalytic wet oxidation of phenolic wastewaters. Second, several experimental and computational runs were carried out under unsteady-state operation to evaluate the dynamic performance addressing the TOC concentration and temperature profiles. CFD computations of total organic carbon conversion were found to agree better with experimental data at lower temperatures. Finally, the comparison of test data with simulation results demonstrated that this integrated framework was able to describe the mineralization of organic matter in trickle beds and the validated consequence model can be exploited to promote cleaner remediation technologies of contaminated waters.

  19. Performance and population analysis of a non-sterile trickle bed reactor inoculated with caldicellulosiruptor saccharolyticus, a thermophilic hydrogen producer

    NARCIS (Netherlands)

    Groenestijn, J.W. van; Geelhoed, J.S.; Goorissen, H.P.; Meesters, K.P.M.; Stams, A.J.M.; Claassen, P.A.M.

    2009-01-01

    Non-axenic operation of a 400 L trickle bed reactor inoculated with the thermophile Caldicellulosiruptor saccharolyticus, yielded 2.8 molH 2mol hexose converted. The reactor was fed with a complex medium with sucrose as the main substrate, continuously flushed with nitrogen gas, and operated at

  20. Performance and population analysis of a non-sterile trickle bed reactor inoculated with Caldicellulosiruptor saccharolyticus, a thermophilic hydrogen producer

    NARCIS (Netherlands)

    Groenestijn, van J.W.; Geelhoed, J.S.; Goorissen, H.P.; Meesters, K.P.H.; Stams, A.J.M.; Claassen, P.A.M.

    2009-01-01

    Non-axenic operation of a 400 L trickle bed reactor inoculated with the thermophile Caldicellulosiruptor saccharolyticus, yielded 2.8 mol H2/mol hexose converted. The reactor was fed with a complex medium with sucrose as the main substrate, continuously flushed with nitrogen gas, and operated at

  1. Single-stage revision from gastric band to gastric bypass or sleeve gastrectomy: 6- and 12-month outcomes.

    Science.gov (United States)

    Yeung, Louise; Durkan, Brandice; Barrett, Allison; Kraft, Cary; Vu, Kim; Phillips, Edward; Cunneen, Scott; Burch, Miguel

    2016-06-01

    Laparoscopic adjustable gastric banding (LAGB) is increasingly requiring revisional surgery for complications and failures. Removal of the band and conversion to either laparoscopic Roux-en-y gastric bypass (LRYGB) or laparoscopic sleeve gastrectomy (LSG) is feasible as a single-stage procedure. The objective of this study is to compare the safety and efficacy of single-stage revision from LAGB to either LRYGB or LSG at 6 and 12 months postoperatively. Retrospective analysis was performed on patients undergoing single-stage revision between 2009 and 2014 at a single academic medical center. Patients were reassessed for weight loss and complications at 6 and 12 months postoperatively. Thirty-two patients underwent single-stage revision to LRYGB, and 72 to LSG. Preoperative BMIs were similar between the two groups (p = 0.27). Median length of stay for LRYGB was 3 days versus 2 for LSG (p = 0.14). Four patients in the LRYGB group required reoperation within 30 days, and two patients in the LSG group required reoperation within 30 days (p = 0.15). There was no difference in ER visits (p = 0.24) or readmission rates (p = 0.80) within 30 days of operation. Six delayed complications were seen in the LSG group with three requiring intervention. At 6 months postoperatively, percent excess weight loss (%EWL) was 50.20 for LRYGB and 30.64 for LSG (p = 0.056). At 12 months, %EWL was 51.19 for LRYGB and 34.89 for LSG (p = 0.31). There was no difference in diabetes or hypertension medication reduction at 12 months between LRYGB and LSG (p > 0.07). Single-stage revision from LAGB to LRYGB or LSG is technically feasible, but not without complications. The complications in the bypass group were more severe. There was no difference in readmission or reoperation rates, weight loss or comorbidity reduction. Revision to LRYGB trended toward higher rate and greater severity of complications with equivalent weight loss and comorbidity reduction.

  2. Trickle-Down Preferences: Preferential Conformity to High Status Peers in Fashion Choices

    Science.gov (United States)

    Galak, Jeff; Gray, Kurt; Elbert, Igor; Strohminger, Nina

    2016-01-01

    How much do our choices represent stable inner preferences versus social conformity? We examine conformity and consistency in sartorial choices surrounding a common life event of new norm exposure: relocation. A large-scale dataset of individual purchases of women’s shoes (16,236 transactions) across five years and 2,007 women reveals a balance of conformity and consistency, moderated by changes in location socioeconomic status. Women conform to new local norms (i.e., average heel size) when moving to relatively higher status locations, but mostly ignore new local norms when moving to relatively lower status locations. In short, at periods of transition, it is the fashion norms of the rich that trickle down to consumers. These analyses provide the first naturalistic large-scale demonstration of the tension between psychological conformity and consistency, with real decisions in a highly visible context. PMID:27144595

  3. Air purification from a mixture VOCs in the pilot-scale trickle-bed bioreactor (TBB)

    Science.gov (United States)

    Sarzyński, Rafał; Gąszczak, Agnieszka; Janecki, Daniel; Bartelmus, Grażyna

    2017-10-01

    The efficiency of the air bio-purification from the mixture of two volatile organic compounds (styrene and p-xylene) was studied. The process was carried out in a pilot-scale trickle-bed bioreactor installation designed to purify ˜200 m3h-1 of the polluted air. The bioreactor operated at concurrent flow of gas and liquid (mineral salt solution) through packing (polypropylene Ralu rings) covered with a thin layer of microorganisms (bacterial consortium of Pseudomonas sp. E-022150 and Pseudomonas putida mt-2). The experiments, carried out for various values of a reactor load with pollutant, confirmed the great efficiency of the investigated process. At the tested bed load with pollution (inlet specific pollutant load was changed within the range of 41 - 84 gm-3 h -1), styrene conversion degree changed within the range of 80-87% and p-xylene conversion degree within the range of 42-48%.

  4. Trickle-Down Preferences: Preferential Conformity to High Status Peers in Fashion Choices.

    Science.gov (United States)

    Galak, Jeff; Gray, Kurt; Elbert, Igor; Strohminger, Nina

    2016-01-01

    How much do our choices represent stable inner preferences versus social conformity? We examine conformity and consistency in sartorial choices surrounding a common life event of new norm exposure: relocation. A large-scale dataset of individual purchases of women's shoes (16,236 transactions) across five years and 2,007 women reveals a balance of conformity and consistency, moderated by changes in location socioeconomic status. Women conform to new local norms (i.e., average heel size) when moving to relatively higher status locations, but mostly ignore new local norms when moving to relatively lower status locations. In short, at periods of transition, it is the fashion norms of the rich that trickle down to consumers. These analyses provide the first naturalistic large-scale demonstration of the tension between psychological conformity and consistency, with real decisions in a highly visible context.

  5. Deuterium exchange between hydrogen and water in a trickle bed reactor

    International Nuclear Information System (INIS)

    Enright, J.T.; Chuang, T.T.

    1978-01-01

    The catalyzed exchange of deuterium between hydrogen and liquid water has been studied as the basis for a heavy water production process. Platinum catalyst which had been waterproofed with Teflon was tested in a 0.2 m diameter trickle bed reactor at pressures and temperatures up to 6 MPa and 440 K. Extensive experimental data were used to test a model of the system which was developed from fundamental principles. It was found that mass transfer plays a very important role in the overall exchange and the conventional theory of vapour/liquid mass transfer does not adequately describe the absorption process. Modelling of the data has resulted in the postulation of a second method of mass transfer whereby HDO transfers directly from the catalyst to the bulk liquid phase. (author)

  6. Optimisation of hydrogenation reactors with heterogeneous catalysts operated in trickle phase

    Energy Technology Data Exchange (ETDEWEB)

    Knoche, M. [CRI KataLeuna GmbH, Leuna (Germany)

    2010-12-30

    Maldistribution in trickle phase reactors is to be blamed for hot spot formation and non-ideal reaction. For a simple and quick evaluation, a virtually divided reactor model is presented for a better understanding and analysis of the consequences of liquid maldistribution. Based on this modelization, different methods are described to resolve microscopic and macroscopic maldistribution. The same model provides information to produce guidelines for reactor loading and evaluating the uneven effects of coking. It is shown that areas with specifically high liquid loads may suffer from insufficient gas supply and might therewith prevent a proper stoechiometric conversion of the gas with the liquid. In areas with lower liquid load, the gas has less hydraulic resistance and bypasses the effective reaction zone. (orig.)

  7. Air purification from a mixture VOCs in the pilot-scale trickle-bed bioreactor (TBB

    Directory of Open Access Journals (Sweden)

    Sarzyński Rafał

    2017-01-01

    Full Text Available The efficiency of the air bio-purification from the mixture of two volatile organic compounds (styrene and p-xylene was studied. The process was carried out in a pilot-scale trickle-bed bioreactor installation designed to purify ∼200 m3h-1 of the polluted air. The bioreactor operated at concurrent flow of gas and liquid (mineral salt solution through packing (polypropylene Ralu rings covered with a thin layer of microorganisms (bacterial consortium of Pseudomonas sp. E-022150 and Pseudomonas putida mt-2. The experiments, carried out for various values of a reactor load with pollutant, confirmed the great efficiency of the investigated process. At the tested bed load with pollution (inlet specific pollutant load was changed within the range of 41 – 84 gm-3 h -1, styrene conversion degree changed within the range of 80-87% and p-xylene conversion degree within the range of 42-48%.

  8. Single-stage treatment of infected tibial non-unions and osteomyelitis with bone marrow granulocytes precursors protecting bone graft.

    Science.gov (United States)

    Hernigou, Philippe; Dubory, Arnaud; Homma, Yasuhiro; Flouzat Lachaniette, Charles Henri; Chevallier, Nathalie; Rouard, Helene

    2017-11-13

    Infected non-unions present a clinical challenge, especially with risk of recurrent infection. Bone marrow contains granulocyte precursors identified in vitro as colony forming units-granulocyte macrophage (CFU-GM) have a prophylactic action against infection. We therefore tested the hypothesis that bone marrow concentrated granulocytes precursors added to a standard bone graft could decrease the risk of recurrence of infection when single-stage treatment of infected tibial non-unions is performed with bone graft. During a single-stage procedure 40 patients with infected tibial non-union received a spongious bone graft supercharged with granulocytes precursors after debridement (study group). A control group (40 patients) was treated in a single stage with local debridement and standard bone graft obtained from the iliac crest. The antibiotic therapy protocol was the same (60 days) in the two groups. CFU-GM progenitors were harvested from bone marrow aspirated on the opposite iliac crest of the site where the cancellous bone was obtained. Union (radiographs and CT scan), a recurrence of clinical infection, and need for subsequent surgery were evaluated. Thirty-eight (95%) patients who received graft supercharged with granulocytes precursors achieved successful union without recurrence of infection during the seven-year follow-up versus 28 (70%) control patients; for the control group the mean graft resorption volume was 40%, while no bone graft resorption was found for the study group. Supercharging the cancellous bone graft with bone marrow granulocytes precursors protect the site of infected non-union from recurrence of infection and bone resorption of the graft.

  9. Thermodynamic analysis of single-stage and multi-stage adsorption refrigeration cycles with activated carbon–ammonia working pair

    International Nuclear Information System (INIS)

    Xu, S.Z.; Wang, L.W.; Wang, R.Z.

    2016-01-01

    Highlights: • Activated carbon–ammonia multi-stage adsorption refrigerator was analyzed. • COP, exergetic efficiency and entropy production of cycles were calculated. • Single-stage cycle usually has the advantages of simple structure and high COP. • Multi-stage cycles adapt to critical conditions better than single-stage cycle. • Boundary conditions for choosing optimal cycle were summarized as tables. - Abstract: Activated carbon–ammonia multi-stage adsorption refrigeration cycle was analyzed in this article, which realized deep-freezing for evaporating temperature under −18 °C with heating source temperature much lower than 100 °C. Cycle mathematical models for single, two and three-stage cycles were established on the basis of thorough thermodynamic analysis. According to simulation results of thermodynamic evaluation indicators such as COP (coefficient of performance), exergetic efficiency and cycle entropy production, multi-stage cycle adapts to high condensing temperature, low evaporating temperature and low heating source temperature well. Proposed cycle with selected working pair can theoretically work under very severe conditions, such as −25 °C evaporating temperature, 40 °C condensing temperature, and 70 °C heating source temperature, but under these working conditions it has the drawback of low cycle adsorption quantity. It was found that both COP and exergetic efficiency are of great reference value in the choice of cycle, whereas entropy production is not so useful for cycle stage selection. Finally, the application boundary conditions of single-stage, two-stage, and three-stage cycles were summarized as tables according to the simulation results, which provides reference for choosing optimal cycle under different conditions.

  10. Single stage reconstruction of ruptured tendoachilles tendon with skin cover using distally based superficial sural artery flap.

    Science.gov (United States)

    Abhyankar, Suhas V; Kulkarni, Ananta; Agarwal, Naveen Kumar

    2009-10-01

    Ruptured tendoachilles along with skin defect is a complex problem to reconstruct. Both things require a priority. Single stage reconstruction of ruptured tendoachilles tendon with skin cover using distally based superficial sural arterial flap allows us to perform both. This procedure gives excellent result, shortens the stay, thereby reducing the cost. This method is a simple solution to the complex problem like ruptured tendoachilles with skin defect. In this study, 6 patients with rupture of tendoachilles tendon due to penetrating injury, with skin defect are presented. The repair was done using aponeurotic part of tendoachilles tendon, taken from proximal part of tendoachilles in the midline measuring around 2 to 2.5 cm in width and 8 to 10 cm in length, with intact distal attachment. The tendon was turned upside down by 180 degrees and sutured to the distal stump of the tendoachilles tendon without tension. The skin defect was covered using distally based superficial sural artery flap in the same sitting. The follow-up period was 9 to 30 months. All patients showed good results. In one patient there was distal necrosis of 1.5 cm of the distally based superficial sural artery flap, which healed satisfactorily with conservative treatment. Single stage tendoachilles reconstruction can be used with good functional result and patient satisfaction.

  11. Aeration effect on the efficiency of swine manure treatment in a trickling filter packed with organic materials.

    Science.gov (United States)

    Garzón-Zúñiga, M A; Lessard, P; Aubry, G; Buelna, G

    2007-01-01

    Effect of aeration rate on the removal of organic matter and nitrogen and on the formation of NH3, N2O and N2 was studied for an extensive biofiltration system packed with an organic media, which was used to treat pig manure. The results show high removal of BOD5 and TSS (99 and > or = 98%), independently of the four aeration rate tested (3.4-34 m3/m2 x h). Aeration rate > or = 4.4 m/h resulted in high ammonia stripping during start-up (> or = 1.0 kg NH3-N/m3 of swine manure treated), while using 3.4 m/h only 0.3 kg NH3-N/m3 were stripped. Complete nitrification was achieved after day 100 of operation, except in the biofilter with the lowest aeration rate. Simultaneous denitrification established in all the biofilters. Applying an aeration rate of 9.4 m/h up to 1.2 kg nitrogen was removed in the form of N2 for each m3 of swine manure treated. Contrary to the expectations, N2 formation and release increased with the aeration rate. This particular behaviour seems to be related to the punctual accumulation of water layers inside the biofilters, caused by the air force flowing in the opposite direction to the water flux. N2O production was quite similar in all biofilters (between 0.25-0.36 kg N2O-N/m3 of swine manure treated).

  12. Single-stage posterior transforaminal lumbar interbody fusion, debridement, limited decompression, 3-column reconstruction, and posterior instrumentation in surgical treatment for single-segment lumbar spinal tuberculosis

    OpenAIRE

    Zeng, Hao; Wang, Xiyang; Zhang, Penghui; Peng, Wei; Zhang, Yupeng; Liu, Zheng

    2015-01-01

    Objective: The aim of this study is to determine the feasibility and efficacy of surgical management of single-segment lumbar spinal tuberculosis (TB) by using single-stage posterior transforaminal lumbar interbody fusion, debridement, limited decompression, 3-column reconstruction, and posterior instrumentation.Methods: Seventeen cases of single-segment lumbar TB were treated with single-stage posterior transforaminal lumbar interbody fusion, debridement, limited decompression, 3-column reco...

  13. Two-stage IMZ implants and ITI implants inserted in a single-stage procedure. A prospective comparative study.

    Science.gov (United States)

    Heydenrijk, Kees; Raghoebar, Gerry M; Meijer, Henny J A; van der Reijden, Willy A; van Winkelhoff, Arie Jan; Stegenga, Boudewijn

    2002-08-01

    The aim of this study was to evaluate the feasibility of using a two-stage implant system in a single-stage procedure and to study the impact of the microgap at crestal level and to monitor the microflora in the peri-implant area. Forty edentulous patients (Cawood & Howell class V-VI) participated in this study. After randomisation, 20 patients received two IMZ implants inserted in a single-stage procedure and 20 patients received two ITI implants. After 3 months, overdentures were fabricated, supported by a bar and clip attachment. A standardised clinical and radiographic evaluation was performed immediately after denture insertion and 6 and 12 months later. Twelve months after loading, peri-implant samples were collected with sterile paper points and analysed for the presence of putative periodontal pathogens using culture techniques. One IMZ implant was lost due to insufficient osseointegration. With regard to the clinical parameters at the 12 months evaluation, significant differences for plaque score and probing pocket depth (IMZ: mean 3.3 mm, ITI: mean 2.9 mm) were found between the two groups. The mean bone loss in the first year of functioning was 0.6 mm for both groups. Prevotella intermedia was detected more often in the ITI group (12 implants) than in the IMZ group (three implants). Porphyromonas gingivalis was found in three patients. In one of these patients an implant showed bone loss of 1.6 mm between T0 and T12. Some associations were found between clinical parameters and the target microorganisms in the ITI group. These associations were not present in the IMZ group. The short-term results indicate that two-stage implants inserted in a single-stage procedure may be as predictable as one-stage implants. The microgap at crestal level in nonsubmerged IMZ implants seems to have no adverse influence on the peri-implant microbiological colonisation and of crestal bone loss in the first year of functioning. The peri-implant sulcus can and does harbour

  14. Results of single-staged rotational osteotomy in a child with congenital proximal radioulnar synostosis: subjective and objective evaluation.

    Science.gov (United States)

    Shingade, Viraj U; Shingade, Rashmi V; Ughade, Suresh N

    2014-01-01

    For congenital proximal radioulnar synostosis, both conservative and operative treatments have been described. Most of the studies describing surgical interventions are based on subjective evaluation of the forearm function and have used severe degree of forearm pronation as an indication for surgery. This study describes a single-staged rotational osteotomy of the proximal third ulna and distal third radius. The aim of the study was to assess the utility of the described surgical procedure by subjective and objective evaluations of the forearm function. Forty-eight children with congenital proximal radioulnar synostosis were evaluated by subjective and objective assessments and were followed up prospectively. Subjective evaluation consisted of a set of 12 questions regarding the basic activities of life. Objective evaluation was made using the Jebsen-Taylor hand-function test and a classification system used by Failla and colleagues for 15 tasks described by Morrey and colleagues. Eleven children were treated conservatively. Thirty-six children underwent a single-staged rotational osteotomy of the proximal third ulna and distal third radius. After surgery, the evaluations were repeated. The mean age at surgery was 8.6±3.7 years, and the mean postoperative follow-up period was 54±13 months. All operated forearms showed a statistically significant improvement in functioning after surgery as per the subjective and objective evaluations. The mean time taken to carry out all activities before surgery was 47.7+10.0 seconds, which significantly reduced to 33.3+6.6 seconds after surgery (P=0.0001) as per the results of the Jebsen-Taylor hand-function test. All good (n=19) and fair (n=11) results were converted to excellent (n=30) after surgery as per the modified Failla classification. There were no neurovascular injuries as compared with other published techniques. Only 1 child had delayed union, and 1 had persistent dorsal angulation at the radial osteotomy site. For

  15. Filter arrays

    Energy Technology Data Exchange (ETDEWEB)

    Page, Ralph H.; Doty, Patrick F.

    2017-08-01

    The various technologies presented herein relate to a tiled filter array that can be used in connection with performance of spatial sampling of optical signals. The filter array comprises filter tiles, wherein a first plurality of filter tiles are formed from a first material, the first material being configured such that only photons having wavelengths in a first wavelength band pass therethrough. A second plurality of filter tiles is formed from a second material, the second material being configured such that only photons having wavelengths in a second wavelength band pass therethrough. The first plurality of filter tiles and the second plurality of filter tiles can be interspersed to form the filter array comprising an alternating arrangement of first filter tiles and second filter tiles.

  16. A Rocket Powered Single-Stage-to-Orbit Launch Vehicle With U.S. and Soviet Engineers

    Science.gov (United States)

    MacConochie, Ian O.; Stnaley, Douglas O.

    1991-01-01

    A single-stage-to-orbit launch vehicle is used to assess the applicability of Soviet Energia high-pressure-hydrocarbon engine to advanced U.S. manned space transportation systems. Two of the Soviet engines are used with three Space Shuttle Main Engines. When applied to a baseline vehicle that utilized advanced hydrocarbon engines, the higher weight of the Soviet engines resulted in a 20 percent loss of payload capability and necessitated a change in the crew compartment size and location from mid-body to forebody in order to balance the vehicle. Various combinations of Soviet and Shuttle engines were evaluated for comparison purposes, including an all hydrogen system using all Space Shuttle Main Engines. Operational aspects of the baseline vehicle are also discussed. A new mass properties program entitles Weights and Moments of Inertia (WAMI) is used in the study.

  17. Advantages of using a two-switch forward in single-stage power factor corrected power supplies

    DEFF Research Database (Denmark)

    Petersen, Lars

    2000-01-01

    A single-stage power factor corrected power supply using a two-switch forward is proposed to increase efficiency. The converter is operated in the DCM (discontinues conduction mode) and it is shown that this operation mode ensures the intermediate DC-bus to be controlled only by means of circuit...... parameters and therefore independent of load variations. The DCM operation often has a diminishing effect on the efficiency but by use of the two-switch topology high efficiency with minimum circuit complexity can be achieved in this mode. A 500 W 70 V prototype of the two-switch boost-forward PFC power...... supply has been implemented. The measured efficiency is between 85% and 88.5% in the range 30 W-500 W and the measured power factor at full load is 0.95....

  18. Bilateral Simultaneous Revision Total Knee Arthroplasty as a Single Staged Procedure: A Case Report and Review of Literature.

    Science.gov (United States)

    Vaishya, Raju; Agarwal, Amit Kumar; Jaiswal, Chirag; Vijay, Vipul; Vaish, Abhishek

    2017-03-23

    Bilateral revision total knee arthroplasty (TKA) is a surgical procedure, which is rarely done simultaneously as it is a difficult surgery and the safety of simultaneous bilateral single stage surgery remains unknown. We report a case of a 67-year-old woman who presented to us with bilateral painful and unstable TKA (right > left) of six months duration. The primary bilateral TKA were done 14 years ago. Bilateral simultaneous revision TKA was performed, using cemented, constrained, long-stem prostheses. The intraoperative and postoperative periods remained uneventful. At last follow-up at four years, she had a pain-free range of motion of up to 0-115°, and the patient had returned to the activities of daily living. She had stable knees with good function and no evidence of loosening or wear.

  19. A rapid method for optimization of the rocket propulsion system for single-stage-to-orbit vehicles

    Science.gov (United States)

    Eldred, C. H.; Gordon, S. V.

    1976-01-01

    A rapid analytical method for the optimization of rocket propulsion systems is presented for a vertical take-off, horizontal landing, single-stage-to-orbit launch vehicle. This method utilizes trade-offs between propulsion characteristics affecting flight performance and engine system mass. The performance results from a point-mass trajectory optimization program are combined with a linearized sizing program to establish vehicle sizing trends caused by propulsion system variations. The linearized sizing technique was developed for the class of vehicle systems studied herein. The specific examples treated are the optimization of nozzle expansion ratio and lift-off thrust-to-weight ratio to achieve either minimum gross mass or minimum dry mass. Assumed propulsion system characteristics are high chamber pressure, liquid oxygen and liquid hydrogen propellants, conventional bell nozzles, and the same fixed nozzle expansion ratio for all engines on a vehicle.

  20. The Naso-labial and lateral forehead flaps as a single stage: A case report and review of literature

    Directory of Open Access Journals (Sweden)

    Adigun I

    2008-01-01

    Full Text Available We present here the case of a patient with a major traumatic nasal loses who had a near-total nasal reconstruction as a single-stage procedure. A 35 year-old civil servant who was involved in a road traffic injury about two years before presentation. He sustained extensive and multiple facial injuries with complete loss of nasal cover and lining. Reconstruction was performed by using superiorly based, bilateral, nasolabial flaps to line the floor and the nasal septum, and a paramedian forehead flap for skin cover. The patient did well postoperatively and was discharged home on the 7 th postoperative day. If the principles concerning cover, support, and lining are adhered to, excellent functional and aesthetic results can be achieved as we have obtained in our patient.

  1. Studies on water turbine runner which fish can pass through: In case of single stage axial runner

    International Nuclear Information System (INIS)

    Shimizu, Yukimari; Maeda, Takao; Nagoshi, Osamu; Ieda, Kazuma; Shinma, Hisako; Hagimoto, Michiko

    1994-01-01

    The relationship between water turbine runner design and operation and the safe passage of fish through the turbine is studied. The kinds of fish used in the tests are a dace, a sweet fish and a small salmon. A single stage axial runner is used. The velocity and pressure distributions were measured inside the turbine casing and along the casing wall. Many pictures showing fish passing through the rotating runner were taken and analyzed. The swimming speed of the fish was examined from video recordings. Fish pass through the runner more rapidly when they can determine and choose the easier path. Injury and mortality of fish are affected by the runner speed and the location of impact of the runner on the fish body

  2. Single stage concrete pumping through 2.432 km (1.51 miles: Weather and execution challenges

    Directory of Open Access Journals (Sweden)

    Chetan Hazaree

    2015-12-01

    Full Text Available This paper describes the execution challenges faced during single stage pumping of concrete through 2.432 km. Pump and pipeline selection and installation, materials’ development, establishing of control points and controlling variations are discussed. Concrete responses to weather changes play a vital role in concreting and pumping methodology development. Measuring pump pressure during pumping can provide insightful guidance to concreting. In order to optimize concrete mixtures, distance-specific mixture designs were developed and a relation between air-free paste volume (AFPV and pumping distance is derived. Pipeline priming and washout procedures specific to long-distance pumping are elaborated in detail. The paper presents a broad understanding regarding the challenges encountered; changes in pumping distance, materials, and climate would change the approach to solutions.

  3. Pathology and clinicopathology of buffalo against trickle infection with Fasciola gigantica

    Directory of Open Access Journals (Sweden)

    Ening Wiedosari

    1998-06-01

    Full Text Available Eleven male buffalo calves were divided into infected group of 7 animals and non-infected control group of 4 animals. The infected group was then inoculated with trickle doses of 15 Inetacercariae of Fasciola gigantica twice weekly for 32 weeks and killed 36 weeks after first infection. There were no clinical symptoms observed . Infected and non-infected buffaloes, had similar values of packed cell volume, haemoglobin and red blood cell counts . In infected buffaloes, plasma glutamate dehydrogenase enzyme activity increased in proportion to the dregree of hepatocyte destruction level and evidence of necrosis caused by the migrating of immature flukes through the parenchyma prior to their entry into the bile ducts. While the values of plasma glutamyl transpeptidase showed only a minimal rise with a small peak in week 20 as evidenced by histological observation that infected caused limited damage to epithelial surface of the bile duct . These results indicates that, the resistance mechaninisms of buffalo against fasciolosis infection occurred in the liver or before flukes entering into the bile ducts. These results seem to indicate that, in buffalo, resistance mechanisms to fasciolosis infection occured in the liver or before flukes entry into the bile ducts.

  4. Selective adhesion of wastewater bacteria to Pleurotus ostreatus mycelium in a trickle-bed bioreactor

    Directory of Open Access Journals (Sweden)

    Čeněk Novotný

    2016-07-01

    Full Text Available The work is focused on spontaneous colonization of fungal mycelium by invading microorganisms in a trickle-bed fungal bioreactor operating under semi-sterile conditions. Pleurotus ostreatus was grown under the flow of synthetic wastewater containing activated sludge bacteria and the microbial consortium developed in the reactor was characterized. Genotype and phenotype profile of the reactor-invading, bacterial consortium was clearly distinctive from that of the original activated sludge. The bacterial consortium from the reactor contained a higher portion of bacteria capable of cellobiose utilization and a small amount of bacteria with the ability to utilize benzoic acids. The invading bacteria had no effect on the dye decolorization performance of the fungal reactor. Five bacterial strains colonizing P. ostreatus reactor cultures were isolated and identified as species of the genera Pseudomonas and Bacillus. Except for Bacillus cereus all strains displayed a potential to inhibit fungal growth on solid media (14 to 51 % inhibition which was comparable or higher than that of the reference bacterial strains. The pH- and media composition-dependence of the growth inhibition was demonstrated.

  5. Continuous aryl alcohol oxidase production under growth-limited conditions using a trickle bed reactor.

    Science.gov (United States)

    Pardo-Planas, Oscar; Atiyeh, Hasan K; Prade, Rolf A; Müller, Michael; Wilkins, Mark R

    2018-05-01

    An A. nidulans strain with a pyridoxine marker was used for continuous production of aryl alcohol oxidase (AAO) in a trickle bed reactor (TBR). Modified medium with reduced zinc, no copper, and 5 g/L ascorbic acid that reduced melanin production and increased AAO productivity under growth limited conditions was used. Two air flow rates, 0.11 L/min (0.1 vvm) and 1.1 L/min (1.0 vvm) were tested. More melanin formation and reduced protein productivity were observed with air flow rate of 1.1 L/min. Three random packings were used as support for the fungus inside the TBR column, two of which were hydrophobic and one which was hydrophilic, and three different dilution rates were tested. The use of GEA BCN 030 hydrophobic packing resulted in greater AAO yield and productivity than the other packings. Increasing dilution rates favored melanin formation and citric, lactic and succinic acid accumulation, which decreased AAO yield and productivity. Copyright © 2018 Elsevier Ltd. All rights reserved.

  6. Start-up and performance characteristics of a trickle bed reactor degrading toluene

    Directory of Open Access Journals (Sweden)

    Ondrej Misiaczek

    2007-09-01

    Full Text Available The objective of this work was to evaluate toluene degradation in a trickle bed reactor when the loading was carried out by changing the air flow rate. The biofiltration system was inoculated with a mixed microbial population, adapted to degradation of hydrophobic compounds. Polypropylene high flow rings were used as a packing material. The system was operated for a period of 50 days at empty bed residence times ranging from 106s to 13s and with a constant inlet concentration of toluene of 100 mg.m-3. The reactor showed high removal efficiency at higher contact times and increasing elimination capacity with higher air-flow rates. The highest EC value reached was 9.8 gC.m-3.h-1 at EBRT = 13s. During the experiment, the consumption of NaOH solution was also measured. No significant variation of this value was found and an average value of 3.84 mmol of NaOH per gram of consumed carbon was recorded.

  7. Ethanol production during semi-continuous syngas fermentation in a trickle bed reactor using Clostridium ragsdalei.

    Science.gov (United States)

    Devarapalli, Mamatha; Atiyeh, Hasan K; Phillips, John R; Lewis, Randy S; Huhnke, Raymond L

    2016-06-01

    An efficient syngas fermentation bioreactor provides a mass transfer capability that matches the intrinsic kinetics of the microorganism to obtain high gas conversion efficiency and productivity. In this study, mass transfer and gas utilization efficiencies of a trickle bed reactor during syngas fermentation by Clostridium ragsdalei were evaluated at various gas and liquid flow rates. Fermentations were performed using a syngas mixture of 38% CO, 28.5% CO2, 28.5% H2 and 5% N2, by volume. Results showed that increasing the gas flow rate from 2.3 to 4.6sccm increased the CO uptake rate by 76% and decreased the H2 uptake rate by 51% up to Run R6. Biofilm formation after R6 increased cells activity with over threefold increase in H2 uptake rate. At 1662h, the final ethanol and acetic acid concentrations were 5.7 and 12.3g/L, respectively, at 200ml/min of liquid flow rate and 4.6sccm gas flow rate. Copyright © 2016 Elsevier Ltd. All rights reserved.

  8. A clinical case of single-stage correction of penetration combined orofacial defect with two microsurgical autografts

    Directory of Open Access Journals (Sweden)

    A. D. Kaprin

    2015-01-01

    Full Text Available After surgical treatment for locally advanced oral tumors with resection of soft tissues, mucosal membrane, and facial skeletal structures, there are penetration combined defects, removal of which is a challenge for reconstructive surgeons. Mandibular repair is one of the problems in the correction of combined oral defects. Surgeons use different grafts to remove mandibular defects. One-flap transplantation does not always solve all reconstruction problems and ensure the repair of the mucosal membrane, a soft-tissue component, skin integuments, and facial skeleton.The authors describe a clinical case of successful single-stage correction of penetration combined orofacial defect after resection of the tongue, mouth floor, en bloc resection of the lower jaw and mental soft tissues, bilateral cervical supramyochoroidal lymphadenectomy, stage LCL CM mandibular defect formation after J. Boyd, by using two microsurgical autografts (a peroneal skin-muscle-skin autograft and a radial skin-fascia one in a 39-year-old female patient clinically diagnosed with carcinoma of the left mandibular alveolar ridge mucosa, Stage IVA (T4аN0M0.The Department of Microsurgery, P.A. Herzen Moscow Oncology Research Institute, Ministry of Health of Russia, has gained experience in comprehensively correcting extensive combined maxillofacial defects with two or more grafts in 27 patients who underwent autografting with a total of 73 flaps. The most functionally incapacitating and life-incompatible defect was removed at Stage 1 of reconstructive treatment. Delayed reconstruction was made after a complex of specialized antitumor therapy and assessment of treatment results in the absence of progressive growth. A great problem during multi-stage defect correction is presented by the lack of recipient vessels after cervical lymphadenectomy, the presence of soft tissue scar changes, trismus, temporomandibular joint ankylosis, contractures and displacement of the edges of the

  9. Wien filter

    NARCIS (Netherlands)

    Mook, H.W.

    1999-01-01

    The invention relates to a Wien filter provided with electrodes for generating an electric field, and magnetic poles for generating a magnetic field, said electrodes and magnetic poles being positioned around and having a finite length along a filter axis, and being positioned around the filter axis

  10. Rectifier Filters

    Directory of Open Access Journals (Sweden)

    Y. A. Bladyko

    2010-01-01

    Full Text Available The paper contains definition of a smoothing factor which is suitable for any rectifier filter. The formulae of complex smoothing factors have been developed for simple and complex passive filters. The paper shows conditions for application of calculation formulae and filters

  11. FILTER TREATMENT

    Science.gov (United States)

    Sutton, J.B.; Torrey, J.V.P.

    1958-08-26

    A process is described for reconditioning fused alumina filters which have become clogged by the accretion of bismuth phosphate in the filter pores, The method consists in contacting such filters with faming sulfuric acid, and maintaining such contact for a substantial period of time.

  12. REDUCTION OF SOIL INFILTRATION AREA THANKS TO THE WASTEWATER SECONDARY TREATMENT FILTERS

    Directory of Open Access Journals (Sweden)

    Marcin Spychała

    2016-05-01

    Full Text Available The aim of the article was to determine the feasibility and advisability of the use of secondary filters applied before discharge of wastewater into the ground in the context of the fulfillment of the conditions of the current Regulation of the Minister of Environment of 18 November 2014 on the conditions to be met during the discharge of wastewater into the water or the ground and on substances particularly harmful to the aquatic environment. Due to expected in practice, an application and popularity, as compared variants, reactors having a very simple construction were used. The average values of removal of BOD5, COD and total suspended solids for three secondary filters technologies: biological trickling filter with natural ventilation, sand filter and nonwoven filter were compared. Additionally, as a fourth option a simple mathematical model has been presented. This model allows to estimate of BOD5 at the outflow from biological trickling filter and to verify the empirical data. Despite a large usefulness, it is rarely used in our country. It has been found the possibility of reduction of the infiltration area (surface area after reduction is 38–63% of the initial value due to the application of secondary filters. In the case of a high initial demand of the terrain area for drainage localization the benefit in costs resulting from the reduction (several thousand of PLN or may even significantly exceed the cost of buying and installing a cheap secondary filter. In addition, reduction the occupied area of the lot (in extreme cases up to 100 m2 by using the secondary filter allows to use the unoccupied space for other purposes, and thus gives additional economic advantage.

  13. A Robust High-Performance GPS L1 Receiver with Single-stage Quadrature Redio-Frequency Circuit

    Science.gov (United States)

    Liu, Jianghua; Xu, Weilin; Wan, Qinq; Liu, Tianci

    2018-03-01

    A low power current reuse single-stage quadrature raido-frequency part (SQRF) is proposed for GPS L1 receiver in 180nm CMOS process. The proposed circuit consists of LNA, Mixer, QVCO, is called the QLMV cell. A two blocks stacked topology is adopted in this design. The parallel QVCO and mixer placed on the top forms the upper stacked block, and the LNA placed on the bottom forms the other stacked block. The two blocks share the current and achieve low power performance. To improve the stability, a float current source is proposed. The float current isolated the local oscillation signal and the input RF signal, which bring the whole circuit robust high-performance. The result shows conversion gain is 34 dB, noise figure is three dB, the phase noise is -110 dBc/Hz at 1MHz and IIP3 is -20 dBm. The proposed circuit dissipated 1.7mW with 1 V supply voltage.

  14. Heat transfer and oil flow studies on a single-stage-to-orbit control-configured winged entry vehicle

    Science.gov (United States)

    Helms, V. T., III; Bradley, P. F.

    1984-01-01

    Results are presented for oil flow and phase change paint heat transfer tests conducted on a 0.006 scale model of a proposed single stage to orbit control configured vehicle. The data were taken at angles of attack up to 40 deg at a free stream Mach number of 10 for Reynolds numbers based on model length of 0.5 x 10 to the 6th power, 1.0 x 10 to the 6th power and 2.0 x 10 to the 6th power. The magnitude and distribution of heating are characterized in terms of angle of attack and Reynolds number aided by an analysis of the flow data which are used to suggest the presence of various three dimensional flow structures that produce the observed heating patterns. Of particular interest are streak heating patterns that result in high localized heat transfer rates on the wing windward surface at low to moderate angles of attack. These streaks are caused by the bow-shock/wing-shock interaction and formation of the wing-shock. Embedded vorticity was found to be associated with these interactions.

  15. Performance Evaluation of Low/Zero Voltage Ride-Through Operations for Single-Stage Single-Phase Photovoltaic Inverters

    DEFF Research Database (Denmark)

    Zhang, Zhen; Yang, Yongheng; Blaabjerg, Frede

    2017-01-01

    With the fast development of distributed power generations, stability and security have attracted extensive attention in the recent years. As a representative of clean energies, Photovoltaic (PV) systems have been installed extensively worldwide. This drives grid-connected requirements to be cont......With the fast development of distributed power generations, stability and security have attracted extensive attention in the recent years. As a representative of clean energies, Photovoltaic (PV) systems have been installed extensively worldwide. This drives grid-connected requirements......-connected single-stage single-phase PV systems in the case of Low/Zero Voltage Ride-Through (LVRT/ZVRT) operation. A comparative analysis of the two LVRT/ZVRT control methods for PV systems is presented. Simulation results are presented, which verifies that the LVRT/ZVRT methods can help the PV systems...... to temporarily ride-through the grid low-/zero-voltage faults. The power phase-angle control method has a better dynamic response....

  16. Transesterification of rapeseed oil for biodiesel production in trickle-bed reactors packed with heterogeneous Ca/Al composite oxide-based alkaline catalyst.

    Science.gov (United States)

    Meng, Yong-Lu; Tian, Song-Jiang; Li, Shu-Fen; Wang, Bo-Yang; Zhang, Min-Hua

    2013-05-01

    A conventional trickle bed reactor and its modified type both packed with Ca/Al composite oxide-based alkaline catalysts were studied for biodiesel production by transesterification of rapeseed oil and methanol. The effects of the methanol usage and oil flow rate on the FAME yield were investigated under the normal pressure and methanol boiling state. The oil flow rate had a significant effect on the FAME yield for the both reactors. The modified trickle bed reactor kept over 94.5% FAME yield under 0.6 mL/min oil flow rate and 91 mL catalyst bed volume, showing a much higher conversion and operational stability than the conventional type. With the modified trickle bed reactor, both transesterification and methanol separation could be performed simultaneously, and glycerin and methyl esters were separated additionally by gravity separation. Copyright © 2013 Elsevier Ltd. All rights reserved.

  17. Trickle or clumped infection process? A stochastic model for the infection process of the parasitic roundworm of humans, Ascaris lumbricoides.

    Science.gov (United States)

    Walker, Martin; Hall, Andrew; Basáñez, María-Gloria

    2010-10-01

    The importance of the mode of acquisition of infectious stages of directly-transmitted parasitic helminths has been acknowledged in population dynamics models; hosts may acquire eggs/larvae singly in a "trickle" type manner or in "clumps". Such models have shown that the mode of acquisition influences the distribution and dynamics of parasite loads, the stability of host-parasite systems and the rate of emergence of anthelmintic resistance, yet very few field studies have allowed these questions to be explored with empirical data. We have analysed individual worm weight data for the parasitic roundworm of humans, Ascaris lumbricoides, collected from a three-round chemo-expulsion study in Dhaka, Bangladesh, with the aim of discerning whether a trickle or a clumped infection process predominates. We found that hosts tend to harbour female worms of a similar weight, indicative of a clumped infection process, but acknowledged that unmeasured host heterogeneities (random effects) could not be completely excluded as a cause. Here, we complement our previous statistical analyses using a stochastic infection model to simulate sizes of individual A. lumbricoides infecting a population of humans. We use the intraclass correlation coefficient (ICC) as a quantitative measure of similarity among simulated worm sizes and explore the behaviour of this statistic under assumptions corresponding to trickle or clumped infections and unmeasured host heterogeneities. We confirm that both mechanisms are capable of generating aggregates of similar-sized worms, but that the particular pattern of ICCs described pre- and post-anthelmintic treatment in the data is more consistent with aggregation generated by clumped infections than by host heterogeneities alone. This provides support to the notion that worms may be acquired in clumps. We discuss our results in terms of the population biology of A. lumbricoides and highlight the significance of our modelling approach for the study of the

  18. ANALYSIS OF TRICKLE BED AND PACKED BUBBLE COLUMN BIOREACTORS FOR COMBINED CARBON OXIDATION AND NITRIFICATION

    Directory of Open Access Journals (Sweden)

    Iliuta I.

    2002-01-01

    Full Text Available Biological removal of nitrogen and carbon by combined nitrification-oxidation in gas-liquid trickle-bed reactors (TBRs and packed bubble columns (PBCs was analyzed theoretically using a transient two-dimensional model. The model describes TBR and PBC performances at steady state as well as their transient response to a pulse or step increase in inlet methanol and NH4+-nitrogen concentrations. The hydrodynamic parameters were determined from residence time distribution measurements, using an imperfect pulse method for time-domain analysis of nonideal pulse tracer response. A transient diffusion model of the tracer in the porous particle coupled with the piston-dispersion-exchange model was used to interpret the residence time distribution curves obtained. Gas-liquid mass transfer parameters were determined by a stationary method based on the least-squares fit of the calculated concentration profiles in gas phase to the experimental values. Analysis of steady-state performances showed that under like operating conditions, the TBR outperforms the PBC in terms of conversions. A pulse change in the inlet methanol or NH4+-nitrogen concentration causes a negligible transient change in the outlet methanol concentration and a negligible or high transient change in the outlet NH4+-nitrogen concentration. A step change in the inlet methanol concentration causes the negligible transient change in the methanol outlet concentration and a relatively important transient change in the NH4+-nitrogen outlet concentration. A step increase in the NH4+-nitrogen inlet concentration induces a drastic transient change in the NH4+-nitrogen outlet concentration but a negligible transient change in the methanol outlet concentration.

  19. Biological biogas upgrading capacity of a hydrogenotrophic community in a trickle-bed reactor

    International Nuclear Information System (INIS)

    Rachbauer, Lydia; Voitl, Gregor; Bochmann, Günther; Fuchs, Werner

    2016-01-01

    Highlights: • Data on long term operation of a system supplied with real biogas are presented. • Ex-situ biological methanation is feasible for biogas upgrading. • Gas quality obtained complies with strictest direct grid injection criteria. • Biomethane can act as flexible storage for renewable surplus electricity. - Abstract: The current study reports on biological biogas upgrading by means of hydrogen addition to obtain biomethane. A mesophilic (37 °C) 0.058 m 3 trickle-bed reactor with an immobilized hydrogenotrophic enrichment culture was operated for a period of 8 months using a substrate mix of molecular hydrogen (H 2 ) and biogas (36–42% CO 2 ). Complete CO 2 conversion (> 96%) was achieved up to a H 2 loading rate of 6.5 m n 3 H 2 /m 3 reactor vol. × d, corresponding to 2.3 h gas retention time. The optimum H 2 /CO 2 ratio was determined to be between 3.67 and 4.15. CH 4 concentrations above 96% were achieved with less than 0.1% residual H 2 . This gas quality complies even with tightest standards for grid injection without the need for additional CO 2 removal. If less rigid standards must be fulfilled H 2 loading rates can be almost doubled (10.95 versus 6.5 m n 3 H 2 /m 3 reactor vol. × d) making the process even more attractive. At this H 2 loading the achieved methane productivity was 2.52 m n 3 CH 4 /m 3 reactor vol. × d. In terms of biogas this corresponds to an upgrading capacity of 6.9 m n 3 biogas/m 3 reactor vol. × d. The conducted experiments demonstrate that biological methanation in an external reactor is well feasible for biogas upgrading under the prerequisite that an adequate H 2 source is available.

  20. Efficacy of single-stage and two-stage Fowler–Stephens laparoscopic orchidopexy in the treatment of intraabdominal high testis

    Directory of Open Access Journals (Sweden)

    Chang-Yuan Wang

    2017-11-01

    Conclusion: In the case of testis with good collateral circulation, single-stage F-S laparoscopic orchidopexy had the same safety and efficacy as the two-stage F-S procedure. Surgical options should be based on comprehensive consideration of intraoperative testicular location, testicular ischemia test, and collateral circumstances surrounding the testes. Under the appropriate conditions, we propose single-stage F-S laparoscopic orchidopexy be preferred. It may be appropriate to avoid unnecessary application of the two-stage procedure that has a higher cost and causes more pain for patients.

  1. Filter unit

    International Nuclear Information System (INIS)

    Shiba, Kazuo; Nagao, Koji; Akiyama, Toshio; Tanaka, Fumikazu; Osumi, Akira; Hirao, Yasuhiro.

    1997-01-01

    The filter unit is used by attaching to a dustproof mask, and used in a radiation controlled area such as in a nuclear power plant. The filter unit comprises sheet-like front and back filtering members disposed vertically in parallel, a spacer for keeping the filtering members to a predetermined distance and front and back covering members for covering the two filtering members respectively. An electrostatic filter prepared by applying resin-fabrication to a base sheet comprising 100% by weight of organic fibers as fiber components, for example, wool felt, synthetic fiber non-woven fabric, wool and synthetic fiber blend non-woven fabric and then electrifying the resin is used for the filtering members. Then, residue of ashes can be eliminated substantially or completely after burning them. (I.N.)

  2. Effects of a saturated layer and recirculation on nitrogen treatment performances of a single stage Vertical Flow Constructed Wetland (VFCW).

    Science.gov (United States)

    Prigent, S; Paing, J; Andres, Y; Chazarenc, F

    2013-01-01

    Upgrades to enhance nitrogen removal were tested in a 2 year old pilot vertical flow constructed wetland in spring and summer periods. The effects of a saturated layer and of recirculation were tested in particular. Two pilots (L = 2 m, W = 1.25 m, H = 1.2 m), filled with expanded schist (Mayennite(®)), were designed with hydraulic saturated layers of 20 and 40 cm at the bottom. Each pilot was fed with raw domestic wastewater under field conditions according to a hydraulic load of 15-38 cm d(-1) (i.e. 158-401 g COD (chemical oxygen demand) m(-2) d(-1)) and to recirculation rates ranging from 0% up to 150%. The initial load during the first 2 years of operation resulted in an incomplete mineralized accumulated sludge leading to total suspended solids (TSS), COD and biochemical oxygen demand (BOD5) release. A 40 cm hydraulic saturated layer enabled an increase of 5-10% total nitrogen (TN) removal compared to a 20 cm saturated layer. Recirculation allowed the dilution of raw wastewater and enhanced nitrification in a single stage. A design of 1.8 m² pe(-1) (48 cm d(-1), 191 g COD m(-2) d(-1)) with a 40 cm saturated layer and 100% recirculation enabled the French standard D4 (35 mg TSS L(-1), 125 mg COD L(-1), 25 mg BOD5 L(-1)), nitrogen concentrations below 20 mg TKN (total Kjeldahl nitrogen) L(-1) and 50 mg TN L(-1), to be met.

  3. Influence of the effectiveness of raw materials on the reliability of thermoelectric cooling devices. Part I: single-stage TEDs

    Directory of Open Access Journals (Sweden)

    Zaikov V. P.

    2015-02-01

    Full Text Available Increase of the reliability of information systems depends on the reliability improvement of their component elements, including cooling devices, providing efficiency of thermally loaded components. Thermoelectric devices based on the Peltier effect have significant advantages compared with air and liquid systems for thermal modes of the radio-electronic equipment. This happens due to the absence of moving parts, which account for the failure rate. The article presents research results on how thermoelectric efficiency modules affect the failure rate and the probability of non-failure operation in the range of working temperature of thermoelectric coolers. The authors investigate a model of relative failure rate and the probability of failure-free operation single-stage thermoelectric devices depending on the main relevant parameters: the operating current flowing through the thermocouple and resistance, temperature changes, the magnitude of the heat load and the number of elements in the module. It is shown that the increase in the thermoelectric efficiency of the primary material for a variety of thermocouple temperature changes causes the following: maximum temperature difference increases by 18%; the number of elements in the module decreases; cooling coefficient increases; failure rate reduces and the probability of non-failure operation of thermoelectric cooling device increases. Material efficiency increase by 1% allows reducing failure rate by 2,6—4,3% in maximum refrigeration capacity mode and by 4,2—5,0% in minimal failure rate mode when temperature difference changes in the range of 40—60 K. Thus, the increase in the thermoelectric efficiency of initial materials of thermocouples can significantly reduce the failure rate and increase the probability of failure of thermoelectric coolers depending on the temperature difference and the current operating mode.

  4. Prospective study of single-stage repair of contaminated hernias using a biologic porcine tissue matrix: the RICH Study.

    Science.gov (United States)

    Itani, Kamal M F; Rosen, Michael; Vargo, Daniel; Awad, Samir S; Denoto, George; Butler, Charles E

    2012-09-01

    In the presence of contamination, the repair of a ventral incisional hernia (VIH) is challenging. The presence of comorbidities poses an additional risk for postoperative wound events and hernia recurrence. To date, very few studies describe the outcomes of VIH repair in this high-risk population. A prospective, multicenter, single-arm, the Repair of Infected or Contaminated Hernias study was performed to study the clinical outcomes of open VIH repair of contaminated abdominal defects with a non-cross-linked, porcine, acellular dermal matrix, Strattice. Of 85 patients who consented to participate, 80 underwent open VIH repair with Strattice. Hernia defects were 'clean-contaminated' (n = 39), 'contaminated' (n = 39), or 'dirty' (n = 2), and the defects were classified as grade 3 (n = 60) or grade 4 (n = 20). The midline was restored, and primary closure was achieved in 64 patients; the defect was bridged in 16 patients. At 24 months, 53 patients (66%) experienced 95 wound events. There were 28 unique, infection-related events in 24 patients. Twenty-two patients experienced seromas, all but 5 of which were transient and required no intervention. No unanticipated adverse events occurred, and no tissue matrix required complete excision. There were 22 hernia (28%) recurrences by month 24. There was no correlation between infection-related events and hernia recurrence. The use of the intact, non-cross-linked, porcine, acellular dermal matrix, Strattice, in the repair of contaminated VIH in high-risk patients allowed for successful, single-stage reconstruction in >70% of patients followed for 24 months after repair. Published by Mosby, Inc.

  5. Characterization and single-stage denitrification anaerobic digestion of spent stream from the hydrolysis-fermentation-combustion process

    Science.gov (United States)

    Singh, Ramnik

    The demand for ethanol as an oxygenate and octane booster in automobile fuel is growing. A number of processes are being investigated for conversion of biomass to ethanol. The Hydrolysis-Fermentation-Combustion (HFC) process for fuel ethanol production developed at the University of California Forest Products Laboratory, Richmond, California is at the stage of technology transfer following over two decades of research and development. This study addresses the technology to be used in treatment of spent streams to be discharged from this process. The treatment design combines a single stage denitrification and anaerobic digestion (SSDAD) for the biological treatment of a representative stream from this process. A typical spent stream contained a wide range of soluble organic materials including: unfermented sugars, components of the feedstocks solubilized in the hydrolysis, acid degradation products of carbohydrates, cleavage products of lignin, water-soluble extractives and phenolics, terpenes and other unfermented organic material, and nitrate ion from the nitric acid used as a catalyst in the hydrolysis reaction. Three sets of experiments were conducted in laboratory scale anaerobic digesters. Commonly available anaerobic sludge from local sewage treatment plants was used as a starter seed and was successfully acclimated to the high nitrate substrate leading to enrichment of denitrifiers. Necessary nutrients and trace elements were identified and supplied to satisfy the obligatory requirements of different groups of bacterial groups present. A major finding was the unique role of ammonium hydroxide in controlling pH leading to steady-state operation of the digester. At steady state operation the reduction in COD was 65%, the nitrate reduction was 88% and the nitrite reduction was 100%. Nitrate was reduced to safe nitrogen gas without buildup of any intermediate products. Organic material was converted to useful methane gas and carbon dioxide. The SSDAD system was

  6. An operational protocol for facilitating start-up of single-stage autotrophic nitrogen-removing reactors based on process stoichiometry

    DEFF Research Database (Denmark)

    Mutlu, Ayten Gizem; Vangsgaard, Anna Katrine; Sin, Gürkan

    2013-01-01

    Start-up and operation of single-stage nitritation–anammox sequencing batch reactors (SBRs) for completely autotrophic nitrogen removal can be challenging and far from trivial. In this study, a step-wise procedure is developed based on stoichiometric analysis of the process performance from...

  7. Clinical and radiologic evaluation of 2-stage IMZ implants placed in a single-stage procedure : 2-year results of a prospective comparative study

    NARCIS (Netherlands)

    Heydenrijk, K; Raghoebar, GM; Meijer, HJA; Stegenga, B

    2003-01-01

    Purpose: The aim of this study was to evaluate the feasibility of using a 2-stage implant system in a single-stage procedure and to study the impact of the microgap between the implant and the abutment. Materials and Methods: Sixty edentulous patients (Cawood class V or VI) participated in this

  8. Temperature-phased anaerobic digestion of food waste: A comparison with single-stage digestions based on performance and energy balance.

    Science.gov (United States)

    Xiao, Benyi; Qin, Yu; Zhang, Wenzhe; Wu, Jing; Qiang, Hong; Liu, Junxin; Li, Yu-You

    2018-02-01

    The temperature-phased anaerobic digestion (TPAD) of food waste was studied for the purpose of comparing with single-stage mesophilic and thermophilic anaerobic digestion. The biogas and methane yields in the TPAD during the steady period were 0.759 ± 0.115 L/g added VS and 0.454 ± 0.201 L/g added VS, which were lower than those in the two single-stage anaerobic digestion. The improper sludge retention time may be the reason for the lower biogas and methane production in TPAD. The removal of volatile solids in the TPAD was 78.55 ± 4.59% and the lowest among the three anaerobic digestion processes. The reaction ratios of the four anaerobic digestion steps in the TPAD were all lower than those in the two single-stage anaerobic digestion. The energy conversion efficiency of the degraded substrate in the TPAD was similar with those in single-stage mesophilic and thermophilic anaerobic digestion systems. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. Characteristics and Sampling Efficiencies of Two Impactor Bioaerosol Samplers: MAS-100(Registered) (Microbial Air Monitoring System) and Single-Stage Andersen Viable Microbial Samplers

    National Research Council Canada - National Science Library

    Hottell, K

    2004-01-01

    .... A petri dish with agar is used as the impaction surface for these samplers. The MAS-l00 is a single-stage impactor that aspirates air through a 400-hole perforated entry plate onto an agar plate at an airflow rate of 100 L/min...

  10. Wien filter

    OpenAIRE

    Mook, H.W.

    1999-01-01

    The invention relates to a Wien filter provided with electrodes for generating an electric field, and magnetic poles for generating a magnetic field, said electrodes and magnetic poles being positioned around and having a finite length along a filter axis, and being positioned around the filter axis such that electric and magnetic forces induced by the respective fields and exerted on an electrically charged particle moving substantially along the fileter axis at a certain velocity

  11. The Performance of the Trickle Bed Reactor Packed with the Pt/SDBC Catalyst Mixture for the CECE Process

    International Nuclear Information System (INIS)

    Seungwoo Paek; Do-Hee Ahn; Heui-Joo Choi; Kwang-Rag Kim; Hongsuk Chung; Sung-Paal Yim; Minsoo Lee; Kyu-Min Song; Soon Hwan Sohn

    2006-01-01

    The CECE (Combined Electrolysis Catalytic Exchange) process with a hydrophobic catalyst is a very effective method to remove small quantities of tritium from light or heavy waste water streams because of its high separation factor and mild operating conditions. The CECE process is composed of an electrolysis cell and a LPCE (Liquid Phase Catalytic Exchange) column. This paper describes the experimental results of the hydrogen isotopic exchange reaction in a trickle bed reactor packed with a hydrophobic catalyst for the development of the LPCE column of the CECE process. The hydrophobic Pt/SDBC (Styrene Divinyl Benzene Copolymer) catalyst has been developed by Korean researchers for the LPCE column of WTRF (Wolsong Tritium Removal Facility). An experimental apparatus was constructed for the various experiments with the different parameters, such as hydrogen flow rate, temperature, and the structure of the mixed catalyst column. The catalyst column was packed with a mixture of hydrophobic catalyst and hydrophilic packing (Dixon gauze ring). The performance of the catalyst bed was expressed as an overall rate constant Kya. To improve the performance of the trickle bed, the modification of the catalyst bed design (changing the shape of the catalyst complex and diluting with inert) has been investigated. (author)

  12. Development of an experimental radioisotope based process tomography system for research applications in a cold trickle bed column

    International Nuclear Information System (INIS)

    Sau, Madhusudan; Kumar, Pravesh; Kumar, Umesh; Acharya, Rajesh; Singh, Gursharan

    2009-01-01

    In chemical and petrochemical engineering applications, random and structured packing are used in process columns to enhance the heat and mass transfer between two phases. The packing used in such columns is meant to obtain a high specific interfacial area. It is of paramount importance for scale-up and design of trickle bed process columns, to understand and predict the complex multiphase fluid dynamics. In simplified terms, the phase holdup, solid packing distribution in terms of density and gas and liquid velocities among other important parameters need to be qualitatively and quantitatively understood. In the petrochemical industry, many processes are carried out using fixed bed reactors with concurrent upward and downward gas and liquid flows. In order to characterize the liquid and gas flow distribution through a mock-up column, data on planar and volume density distribution using computed tomographic measurements are very helpful. The paper describes the development efforts of a multi-detector 137 Cs radioisotope based in-situ tomography scanner suitable for 600mm dia. cold trickle bed reactor. The development work is at present in progress. The schematics and development of the scanner gantry is described in this paper. (author)

  13. Single-stage epidural catheter lavage with posterior spondylodesis in lumbar pyogenic spondylodiscitis with multilevel epidural abscess formation.

    Science.gov (United States)

    Tschoeke, Sven K; Kayser, Ralph; Gulow, Jens; Hoeh, Nicolas von der; Salis-Soglio, Georg von; Heyde, Christoph

    2014-11-01

    Despite significant advances in the conservative management of pyogenic spondylodiscitis, consecutive instability, deformity, and/or neurologic compromise demands a prompt surgical intervention. However, in rare cases involving additional multilevel epidural abscess formation, the appropriate surgical strategy remains controversial. In this retrospective cohort analyses, we evaluated the efficacy of a single-stage posterior approach with the addition of a one-time multilevel epidural lavage via the surgically exposed interlaminar fenestration of the infected segment. From January 2009 through December 2010, 73 patients presenting pyogenic spondylodiscitis with instability of the lumbar spine were admitted. In all cases, the surgical strategy included a radical resection of the affected intervertebral disc and stabilization by intervertebral fusion using a titanium cage with autologous bone grafting in a level-dependent posterior approach with additional pedicle screw-and-rod instrumentation. In cases where multilevel abscess formation was evident, the standard surgical procedure was complemented by drainage and irrigation of the abscess from posterior by carefully advancing a soft infant feeding tube via the surgically exposed epidural space under fluoroscopic guidance. All patients received complementary oral antibiotic therapy for 12 weeks and were followed-up for a minimum of 12 months postoperatively. Ten patients (three male and seven female patients; mean age: 64.9 ± 10.9 years) presented with an additional lumbar epidural abscess extending beyond three levels proximal or distal to the infected disc. In all 10 patients the laboratory-chemical inflammatory parameters (leukocyte count, C-reactive protein) remained within the physiologic range after completing antibiotic therapy throughout the 1-year follow-up period. The plain radiographs and magnetic resonance imaging demonstrated solid fusion and the complete remission of the initial abscess formation after

  14. Rapid near-optimal trajectory generation and guidance law development for single-stage-to-orbit airbreathing vehicles

    Science.gov (United States)

    Calise, A. J.; Flandro, G. A.; Corban, J. E.

    1990-01-01

    General problems associated with on-board trajectory optimization, propulsion system cycle selection, and with the synthesis of guidance laws were addressed for an ascent to low-earth-orbit of an air-breathing single-stage-to-orbit vehicle. The NASA Generic Hypersonic Aerodynamic Model Example and the Langley Accelerator aerodynamic sets were acquired and implemented. Work related to the development of purely analytic aerodynamic models was also performed at a low level. A generic model of a multi-mode propulsion system was developed that includes turbojet, ramjet, scramjet, and rocket engine cycles. Provisions were made in the dynamic model for a component of thrust normal to the flight path. Computational results, which characterize the nonlinear sensitivity of scramjet performance to changes in vehicle angle of attack, were obtained and incorporated into the engine model. Additional trajectory constraints were introduced: maximum dynamic pressure; maximum aerodynamic heating rate per unit area; angle of attack and lift limits; and limits on acceleration both along and normal to the flight path. The remainder of the effort focused on required modifications to a previously derived algorithm when the model complexity cited above was added. In particular, analytic switching conditions were derived which, under appropriate assumptions, govern optimal transition from one propulsion mode to another for two cases: the case in which engine cycle operations can overlap, and the case in which engine cycle operations are mutually exclusive. The resulting guidance algorithm was implemented in software and exercised extensively. It was found that the approximations associated with the assumed time scale separation employed in this work are reasonable except over the Mach range from roughly 5 to 8. This phenomenon is due to the very large thrust capability of scramjets in this Mach regime when sized to meet the requirement for ascent to orbit. By accounting for flight path

  15. Development of a protective immunity against Ostertagia leptospicularis in trickle-infected sheep and parallel changes of serum gastrin, pepsinogen and antibody levels

    NARCIS (Netherlands)

    Hertzberg, H.; Schallig, H. D.; Deplazes, P.

    1999-01-01

    Nine lambs, approximately 9 months of age were allocated to three groups (A, B, C), with three animals in each. Sheep in Groups A and B were trickle-infected with doses of 1000 third-stage larvae (L3) of Ostertagia leptospicularis (five times per week) over periods of 7.5 and 10.5 weeks,

  16. Modelling of non-catalytic reactors in a gas-solid trickle flow reactor: Dry, regenerative flue gas desulphurization using a silica-supported copper oxide sorbent

    NARCIS (Netherlands)

    Kiel, J.H.A.; Kiel, J.H.A.; Prins, W.; van Swaaij, Willibrordus Petrus Maria

    1992-01-01

    A one-dimensional, two-phase dispersed plug flow model has been developed to describe the steady-state performance of a relatively new type of reactor, the gas-solid trickle flow reactor (GSTFR). In this reactor, an upward-flowing gas phase is contacted with as downward-flowing dilute solids phase

  17. Deuterium exchange reaction in a trickle bed packed with a mixture of hydrophobic catalyst and hydrophilic packings

    Energy Technology Data Exchange (ETDEWEB)

    Seungwoo Paek [KAERI (Korea, Republic of); Heui-Joo Choi; DO-Hee Ahn; Kwang-Rag Kim; Minsoo Lee; Sung-Paal Yim; Hongsuk Chung

    2006-07-01

    Full text of publication follows: The isotopic exchange reaction between hydrogen and water on the platinum supported catalysts provides a useful step for separating hydrogen isotopes such as deuterium and tritium. The CECE (Combined Electrolysis Catalytic Exchange) with a hydrophobic catalyst is a very effective method to remove small quantities of tritium from light or heavy waste water streams because of its high separation factor and mild operating conditions. The CECE column is composed of an electrolysis cell and a liquid phase catalytic exchange column. This paper deals with the experiments for the hydrogen isotopic exchange reaction in a trickle bed reactor packed with a hydrophobic catalyst in order to develop the catalytic column of the CECE. Hydrophobic Pt/SDBC catalyst which has been developed for the LPCE column of WTRF (Wolsong Tritium Removal Facility) was tested in a trickle bed reactor. The catalyst column was packed with a mixture of hydrophobic catalyst and hydrophilic packing (Dixon gauze ring) to improve liquid distribution and vapor/liquid transfer area. An experimental apparatus was built for the test of the catalyst at various temperatures and gas velocities. The catalyst was packed wet into the column and water was injected at the top through a liquid distributor and trickled through a catalyst mixture. Hydrogen gas passed up the column and deuterium was transferred to water stream flowing counter currently. The temperature of the column was controlled to maintain at 60 deg. C using water jackets around the reactor and equilibrator, a feed waster heater, and a circulation water heater. A metal bellows pump was used to circulate the hydrogen gas at the typical flow rate of 60 LPM.The reactor pressure was controlled to maintain at 135 kPa (abs) by a water column. Gas samples were drawn off from the top and bottom of the column. The difference in deuterium concentration between the inlet and outlet gas samples was analyzed using Gas

  18. Automatic Laser Light Detection and Filtering Using a Liquid Crystal Lyot Filter

    Science.gov (United States)

    Rees, S.; Staromlynska, J.

    A device which acts as both a simple cw laser warner and anti-dazzle protection device has been designed and tested. The design is based on a single stage, double element, tunable liquid crystal Lyot filter. Laboratory tests have shown that the detection sensitivity of the device for monochromatic cw radiation is approximately 43×10-9 W/cm2 and that the achievable contrast ratio is greater than 100:1 Automatic detection and filtering of a cw laser source has been demonstrated. Results indicate that the algorithm to automatically filter the laser radiation works well and that the extinction obtained is good. Factors which affect the contrast ratio are discussed and improved device design suggested.

  19. Studying the effect of over-modulation on the output voltage of three-phase single-stage grid-connected boost inverter

    Directory of Open Access Journals (Sweden)

    A. Abbas Elserougi

    2013-09-01

    Full Text Available Voltage boosting is very essential issue in renewable-energy fed applications. The classical two-stage power conversion process is typically used to interface the renewable energy sources to the grid. For better efficiency, single-stage inverters are recommended. In this paper, the performance of single-stage three-phase grid-connected boost inverter is investigated when its gain is extended by employing over-modulation technique. Using of over-modulation is compared with the employment of third order harmonic injection. The latter method can increase the inverter gain by 15% without distorting the inverter output voltage. The performance of extended gain grid-connected boost inverter is also tested during normal operation as well as in the presence of grid side disturbances. Simulation and experimental results are satisfactory.

  20. Filter systems

    International Nuclear Information System (INIS)

    Vanin, V.R.

    1990-01-01

    The multidetector systems for high resolution gamma spectroscopy are presented. The observable parameters for identifying nuclides produced simultaneously in the reaction are analysed discussing the efficiency of filter systems. (M.C.K.)

  1. Analysis of trickle-bed reactor for ethanol production from syngas using Clostridium ragsdalei

    Science.gov (United States)

    Devarapalli, Mamatha

    The conversion of syngas components (CO, CO2 and H2) to liquid fuels such as ethanol involves complex biochemical reactions catalyzed by a group of acetogens such as Clostridium ljungdahlii, Clostridium carboxidivorans and Clostridium ragsdalei. The low ethanol productivity in this process is associated with the low solubility of gaseous substrates CO and H2 in the fermentation medium. In the present study, a 1-L trickle-bed reactor (TBR) was analyzed to understand its capabilities to improve the mass transfer of syngas in fermentation medium. Further, semi-continuous and continuous syngas fermentations were performed using C. ragsdalei to evaluate the ability of the TBR for ethanol production. In the mass transfer studies, using 6-mm glass beads, it was found that the overall mass transfer coefficient (kLa/V L) increased with the increase in gas flow rate from 5.5 to 130.5 sccm. Further, an increase in the liquid flow rate in the TBR decreased the kLa/VL due to the increase in liquid hold up volume (VL) in the packing. The highest kLa/VL values of 421 h-1 and 178 h-1 were achieved at a gas flow rate of 130.5 sccm for 6-mm and 3-mm glass beads, respectively. Semi-continuous fermentations were performed with repetitive medium replacement in counter-current and co-current modes. In semi-continuous fermentations with syngas consisting of 38% CO, 5% N2, 28.5% CO2 and 28.5% H2 (by volume), the increase in H2 conversion (from 18 to 55%) and uptake (from 0.7 to 2.2 mmol/h) were observed. This increase was attributed to more cell attachment in the packing that reduced CO inhibition to hydrogenase along the column length and increased the H2 uptake. The maximum ethanol produced during counter-current and co-current modes were 3.0 g/L and 5.7 g/L, respectively. In continuous syngas fermentation, the TBR was operated at dilution rates between 0.006 h-1and 0.012 h -1 and gas flow rates between 1.5 sccm and 18.9 sccm. The highest ethanol concentration of 13 g/L was achieved at

  2. Immediate two-stage tissue expander vs single-stage direct-to-implant breast reconstruction: two case reports of identical twins with BRCA 2 mutation

    Directory of Open Access Journals (Sweden)

    Aleš Porčnik

    2015-12-01

    Full Text Available In order to achieve the best aesthetic result after immediate implant-based breast reconstruction, all the advantages and disadvantages of two-stage tissue expander and single-stage direct-to-implant breast reconstruction should be considered. Decision about the type of implant-based reconstruction is based on the consultations outcomes after multidisciplinary team meeting of breast and reconstructive specialist, but patients own wishes should be prioritised.

  3. Single-stage oxidative dehydrogenation of n-butaneand isopentane in adiabatic sectional reactors with supply of oxygene and water steam

    International Nuclear Information System (INIS)

    Azizov, A.G; Gadji-Kasumov, V.S

    2000-01-01

    Full text: The advanced technique of single-stage dehydrogenation of n-butane and iso-pentane in adiabatic sectional with separate supply of oxygen on every section is offered. The substance of the novel method consist in water metering for every section. Such technological technique considerably cut the specific energy expenses on high temperature water steam production, increase the yield and selectivity of main products formation at the expense of more complete partial oxidation of the correspondend olefins.

  4. Kinetic modeling of hydrocracking reaction in a trickle-bed reactor with Pt/Y-zeolite catalysts

    Energy Technology Data Exchange (ETDEWEB)

    Lee, BalSang; Park, Myung-June; Kim, Young-A; Park, Eun Duck [Ajou University, Suwon (Korea, Republic of); Han, Jeongsik [Agency for Defense Development, Daejeon (Korea, Republic of); Jeong, Kwang-Eun; Kim, Chul-Ung; Jeong, Soon-Yong [Korea Research Institute of Chemical Technology (KRICT), Daejeon (Korea, Republic of)

    2014-03-15

    A kinetic model is developed to predict the entire distribution of hydrocarbon products for the hydrocracking reaction with Pt/Y-zeolite catalysts in a trickle-bed reactor. Operating conditions, such as temperature, pressure, and wax and H{sub 2} flow rates were varied to evaluate their effects on conversion and distribution, and kinetic parameters were estimated using the experimental data that covers the window of operating conditions. The comparison between experimental data and simulated results corroborated the validity of the developed model, and the quantitative prediction of the reactor performance was clearly demonstrated. To make evident the usefulness of the model, an optimization method, genetic algorithm (GA), was applied, and the optimal condition for the maximum production of C{sub 10}-C{sub 17} was successfully calculated.

  5. Deuterium exchange reaction between hydrogen and water in a trickle-bed column packed with novel catalysts

    International Nuclear Information System (INIS)

    Ahn, D. H.; Baek, S. W.; Lee, H. S.; Kim, K. R.; Kang, H. S.; Lee, S. H.; Jeong, H. S.

    1998-01-01

    The activity of a novel catalyst (Pt/SDBC) for deuterium exchange reaction between water and hydrogen streams in a trickle bed was measured. The performance of the catalyst was compared with a commercial catalyst with same metal content. The catalytic activity for the bed of wet-proofed catalyst diluted with hydrophillic packing material also measured. The Pt/SDBC catalyst shows higher activity in the liquid phase reaction than the commercial catalyst as measured in the vapor phase reaction. The performance for 50% dilution of the Pt/SDBC catalyst bed with hydrophillic packing material is better than that of the 100% bed due to more liquid holdup and better water distribution

  6. Single-stage endoscopic treatment for mild to moderate acute cholangitis associated with choledocholithiasis: a multicenter, non-randomized, open-label and exploratory clinical trial.

    Science.gov (United States)

    Eto, Kazunori; Kawakami, Hiroshi; Haba, Shin; Yamato, Hiroaki; Okuda, Toshinori; Yane, Kei; Hayashi, Tsuyoshi; Ehira, Nobuyuki; Onodera, Manabu; Matsumoto, Ryusuke; Matsubara, Yu; Takagi, Tomofumi; Sakamoto, Naoya

    2015-12-01

    Two-stage treatment involving stone removal after drainage is recommended for mild to moderate acute cholangitis associated with choledocholithiasis. However, single-stage treatment has some advantages. We aimed to assess the efficacy and safety of single-stage endoscopic treatment for mild to moderate acute cholangitis associated with choledocholithiasis. A multicenter, non-randomized, open-label, exploratory clinical trial was performed in 12 institutions. A total of 50 patients with a naïve papilla and a body temperature ≥37 °C who were diagnosed with mild to moderate cholangitis associated with choledocholithiasis were enrolled between August 2012 and February 2014. Of the 50 patients, 15 had mild cholangitis and 35 had moderate cholangitis. The median number of common bile duct stones was 2 (range, 1-8), and the median diameter of the common bile duct stones was 7.5 mm (range, 1-18). The cure rate of acute cholangitis within 4 days after single-stage treatment was 90% (45/50) based on a body temperature choledocholithiasis (clinical trial registration number: UMIN000008494). © 2015 Japanese Society of Hepato-Biliary-Pancreatic Surgery.

  7. Single-stage posterior transforaminal lumbar interbody fusion, debridement, limited decompression, 3-column reconstruction, and posterior instrumentation in surgical treatment for single-segment lumbar spinal tuberculosis.

    Science.gov (United States)

    Zeng, Hao; Wang, Xiyang; Zhang, Penghui; Peng, Wei; Liu, Zheng; Zhang, Yupeng

    2015-01-01

    The aim of this study is to determine the feasibility and efficacy of surgical management of single-segment lumbar spinal tuberculosis (TB) by using single-stage posterior transforaminal lumbar interbody fusion, debridement, limited decompression, 3-column reconstruction, and posterior instrumentation. Seventeen cases of single-segment lumbar TB were treated with single-stage posterior transforaminal lumbar interbody fusion, debridement, limited decompression, 3-column reconstruction, and posterior instrumentation. The mean follow-up was 36.9 months (range: 24-62 months). The kyphotic angle ranged from 15.2-35.1° preoperatively, with an average measurement of 27.8°. The American Spinal Injury Association (ASIA) score system was used to evaluate the neurological deficits and erythrocyte sedimentation rate (ESR) used to judge the activity of TB. Spinal TB was completely cured in all 17 patients. There was no recurrent TB infection. The postoperative kyphotic angle was 6.6-10.2°, 8.1° in average, and there was no significant loss of the correction at final follow-up. Solid fusion was achieved in all cases. Neurological condition in all patients was improved after surgery. Single-stage posterior transforaminal lumbar interbody fusion, debridement, limited decompression, 3-column reconstruction, and posterior instrumentation can be a feasible and effective method the in treatment of single-segment lumbar spinal TB.

  8. Hydrogen Sulfide Removal from Air by Acidithiobacillus thiooxidans in a Trickle Bed Reactor

    Czech Academy of Sciences Publication Activity Database

    Ramirez, M.; Gómez, J. M.; Cantero, D.; Páca, J.; Halecký, M.; Kozliak, E. I.; Sobotka, Miroslav

    2009-01-01

    Roč. 54, č. 5 (2009), s. 409-414 ISSN 0015-5632 Institutional research plan: CEZ:AV0Z50200510 Keywords : 2-STAGE BIOTRICKLING FILTER * THIOBACILLUS-THIOPARUS * DIMETHYL SULFIDE Subject RIV: EE - Microbiology, Virology Impact factor: 0.978, year: 2009

  9. Start-up and Performance Characteristics of a Trickle Bed Reaktor Degrading Toluene

    Czech Academy of Sciences Publication Activity Database

    Misiaczek, O.; Paca, J.; Halecký, M.; Gerrard, A. M.; Sobotka, Miroslav; Soccol, C. R.

    2007-01-01

    Roč. 50, č. 5 (2007), s. 871-877 ISSN 1516-8913 Grant - others:GA ČR(CZ) GA104/05/0194 Institutional research plan: CEZ:AV0Z50200510 Source of funding: V - iné verejné zdroje Keywords : biotrickling filter * constructed mixed population * toluene Subject RIV: EE - Microbiology, Virology Impact factor: 0.349, year: 2007

  10. Does elite success trigger mass participation in table tennis? An analysis of trickle-down effects in Germany, France and Austria.

    Science.gov (United States)

    Haut, Jan; Gaum, Christian

    2017-08-02

    There is a widespread belief that success at the elite level leads to increasing mass participation in sports. However, this assumption is merely supported by empirical evidence and is analyzed here for the case of table tennis. Therefore long-term data (1964-2014) on participation in Germany, France and Austria is statistically tested for effects of success by the countries' athletes at international competitions. Results indicate that no general trickle-down effect can be confirmed for table tennis in the countries observed. Rather, findings are ambivalent, as a strong positive effect was found for the Austrian case, but a paradox relation for the German case, where elite success has been accompanied by decreasing participation in the last decades. Accordingly, as an "automatic" trickle-down effect is unlikely, more specific analyses and strategies seem necessary to use elite success as a lever for the promotion of the sport.

  11. Generalised Filtering

    Directory of Open Access Journals (Sweden)

    Karl Friston

    2010-01-01

    Full Text Available We describe a Bayesian filtering scheme for nonlinear state-space models in continuous time. This scheme is called Generalised Filtering and furnishes posterior (conditional densities on hidden states and unknown parameters generating observed data. Crucially, the scheme operates online, assimilating data to optimize the conditional density on time-varying states and time-invariant parameters. In contrast to Kalman and Particle smoothing, Generalised Filtering does not require a backwards pass. In contrast to variational schemes, it does not assume conditional independence between the states and parameters. Generalised Filtering optimises the conditional density with respect to a free-energy bound on the model's log-evidence. This optimisation uses the generalised motion of hidden states and parameters, under the prior assumption that the motion of the parameters is small. We describe the scheme, present comparative evaluations with a fixed-form variational version, and conclude with an illustrative application to a nonlinear state-space model of brain imaging time-series.

  12. Performance analysis of the single-stage absorption heat transformer using a new working pair composed of ionic liquid and water

    International Nuclear Information System (INIS)

    Zhang Xiaodong; Hu Dapeng

    2012-01-01

    The performance simulation of a single-stage absorption heat transformer using a new working pair composed of ionic liquids, 1-ethyl-3-methylimidazolium dimethylphosphate, and water (H 2 O + [EMIM][DMP]), was performed based on the thermodynamic properties of the new working pair and on the mass and energy balance for each component of the system. In order to evaluate the new working pair, the simulation results were compared with those of aqueous solution of lithium bromide (H 2 O + LiBr), Trifluoroethanol (TFE) + tetraethylenglycol dimethylether (E181). The results indicate that when generation, evaporation, condensing and absorption temperatures are 90 °C, 90 °C, 35 °C and 130 °C, the coefficients of performance of the single-stage absorption heat transformer using H 2 O + LiBr, H 2 O + [EMIM][DMP] and TFE + E181 as working pairs will reach 0.494, 0.481 and 0.458 respectively. And the corresponding exergy efficiency will reach 0.64, 0.62 and 0.59, respectively. Meanwhile the available heat outputs for per unit mass of refrigerant are 2466 kJ/kg, 2344 kJ/kg and 311 kJ/kg, respectively. The above excellent cycle performance together with the advantages of negligible vapor pressure, no crystallization and more weak corrosion tendency to iron-steel materials may make the new working pair better suited for the industrial absorption heat transformer. - Highlights: ► The cycle performance of the single-stage absorption heat transformer was simulated. ► Water and 1-ethyl-3-methylimidazolium dimethylphosphate was used as new working pair. ► Water and 1-ethyl-3-methylimidazolium dimethylphosphate are entirely miscible. ► The COP and exergy efficiency for this new working pairs were 0.481 and 0.62. ► The new working pairs has potential application to absorption heat transformer.

  13. Posterior or Single-stage Combined Anterior and Posterior Approach Decompression for Treating Complex Cervical Spondylotic Myelopathy Coincident Multilevel Anterior and Posterior Compression.

    Science.gov (United States)

    Zhou, Xiaoxiao; Cai, Pan; Li, Yuwei; Wang, Haijiao; Xia, Shengli; Wang, Xiuhui

    2017-12-01

    A single-center, retrospective, longitudinal matched cohort clinical study of prospectively collected outcomes. To compare retrospectively the clinical outcomes and complications of the posterior approach laminoplasty and single-stage anterior approach laminoplasty combined with anterior cervical corpectomy and fusion and anterior cervical discectomy and fusion for treating patients with cervical spondylotic myelopathy coincident multilevel anterior and posterior compression, known as complex cervical spondylotic myelopathy (cCSM) here. The optimal surgical management of this type of cCSM remains controversial. Sixty-seven patients with multilevel cCSM underwent decompression surgery from 1996 to 2007. Among these patients, 31 underwent a single-stage combined approach with decompression (combined approach group) and 36 underwent laminoplasty for posterior approach (posterior approach group). Average operative duration, operative estimated blood loss, surgical costs, and cervical alignment were measured. Average operative duration, operative estimated blood loss, and surgical costs were significantly lower in the posterior approach group than those in the combined approach group (P0.05). No statistical difference was observed in the preoperative Cobb angle (P>0.05), whereas a significant statistical difference was observed for the postoperative Cobb angle (Pgroups. The surgical incidences of complications were 22.2% and 48.4% in the posterior and combined approach groups (Papproach laminoplasty and single-stage combined approach led to significant neurological improvement and pain reduction in the majority of patients. Both approaches showed similar results in terms of decompression and neurological improvement. The posterior approach was superior to the combined approach in terms of surgical costs, surgical time, blood loss, and complication rate.

  14. Retrospective analysis of 56 edentulous dental arches restored with 344 single-stage implants using an immediate loading fixed provisional protocol: statistical predictors of implant failure.

    Science.gov (United States)

    Kinsel, Richard P; Liss, Mindy

    2007-01-01

    The purpose of this retrospective study was to evaluate the effects of implant dimensions, surface treatment, location in the dental arch, numbers of supporting implant abutments, surgical technique, and generally recognized risk factors on the survival of a series of single-stage Straumann dental implants placed into edentulous arches using an immediate loading protocol. Each patient received between 4 and 18 implants in one or both dental arches. Periapical radiographs were obtained over a 2- to 10-year follow-up period to evaluate crestal bone loss following insertion of the definitive metal-ceramic fixed prostheses. Univariate tests for failure rates as a function of age ( or = 60 years), gender, smoking, bone grafting, dental arch, surface type, anterior versus posterior, number of implants per arch, and surgical technique were made using Fisher exact tests. The Cochran-Armitage test for trend was used to evaluate the presence of a linear trend in failure rates regarding implant length and implant diameter. Logistic regression modeling was used to determine which, if any, of the aforementioned factors would predict patient and implant failure. A significance criterion of P = .05 was utilized. Data were collected for 344 single-stage implants placed into 56 edentulous arches (39 maxillae and 17 mandibles) of 43 patients and immediately loaded with a 1-piece provisional fixed prosthesis. A total of 16 implants failed to successfully integrate, for a survival rate of 95.3%. Increased rates of failure were associated with reduced implant length, placement in the posterior region of the jaw, increased implant diameter, and surface treatment. Implant length emerged as the sole significant predictor of implant failure. In this retrospective analysis of 56 consecutively treated edentulous arches with multiple single-stage dental implants loaded immediately, reduced implant length was the sole significant predictor of failure.

  15. Improving fuel quality by whole crude oil hydrotreating: A kinetic model for hydrodeasphaltenization in a trickle bed reactor

    International Nuclear Information System (INIS)

    Jarullah, A.T.; Mujtaba, I.M.; Wood, A.S.

    2012-01-01

    Highlights: ► Asphaltene contaminant must be removed to a large extent from the fuel to meet the regulatory demand. ► Kinetics for hydrodeasphaltenization are estimated via experimentation and modeling. ► Using the kinetic parameters, a full process model for the trickle bed reactor (TBR) is developed. ► The model is used for simulating the behavior of the TBR to get further insight of the process. ► The influences of operating conditions in the hydrodeasphaltenization process are reported. -- Abstract: Fossil fuel is still a predominant source of the global energy requirement. Hydrotreating of whole crude oil has the ability to increase the productivity of middle distillate fractions and improve the fuel quality by simultaneously reducing contaminants such as sulfur, nitrogen, vanadium, nickel and asphaltene to the levels required by the regulatory bodies. Hydrotreating is usually carried out in a trickle bed reactor (TBR) where hydrodesulfurization (HDS), hydrodenitrogenation (HDN), hydrodemetallization (HDM) and hydrodeasphaltenization (HDAs) reactions take place simultaneously. To develop a detailed and a validated TBR process model which can be used for design and optimization of the hydrotreating process, it is essential to develop kinetic models for each of these reactions. Most recently, the authors have developed kinetic models for all of these chemical reactions except that of HDAs. In this work, a kinetic model (in terms of kinetic parameters) for the HDAs reaction in the TBR is developed. A three phase TBR process model incorporating the HDAs reactions with unknown kinetic parameters is developed. Also, a series of experiments has been conducted in an isothermal TBR under different operating conditions affecting the removal of asphaltene. The unknown kinetic parameters are then obtained by applying a parameter estimation technique based on minimization of the sum of square errors (SSEs) between the experimental and predicted concentrations of

  16. Eyeglass Filters

    Science.gov (United States)

    1987-01-01

    Biomedical Optical Company of America's suntiger lenses eliminate more than 99% of harmful light wavelengths. NASA derived lenses make scenes more vivid in color and also increase the wearer's visual acuity. Distant objects, even on hazy days, appear crisp and clear; mountains seem closer, glare is greatly reduced, clouds stand out. Daytime use protects the retina from bleaching in bright light, thus improving night vision. Filtering helps prevent a variety of eye disorders, in particular cataracts and age related macular degeneration.

  17. Effects of sludge recirculation rate and mixing time on performance of a prototype single-stage anaerobic digester for conversion of food wastes to biogas and energy recovery.

    Science.gov (United States)

    Ratanatamskul, Chavalit; Saleart, Tawinan

    2016-04-01

    Food wastes have been recognized as the largest waste stream and accounts for 39.25 % of total municipal solid waste in Thailand. Chulalongkorn University has participated in the program of in situ energy recovery from food wastes under the Ministry of Energy (MOE), Thailand. This research aims to develop a prototype single-stage anaerobic digestion system for biogas production and energy recovery from food wastes inside Chulalongkorn University. Here, the effects of sludge recirculation rate and mixing time were investigated as the main key parameters for the system design and operation. From the results obtained in this study, it was found that the sludge recirculation rate of 100 % and the mixing time of 60 min per day were the most suitable design parameters to achieve high efficiencies in terms of chemical oxygen demand (COD), total solids (TS), and total volatile solid (TVS) removal and also biogas production by this prototype anaerobic digester. The obtained biogas production was found to be 0.71 m(3)/kg COD and the composition of methane was 61.6 %. Moreover, the efficiencies of COD removal were as high as 82.9 % and TVS removal could reach 83.9 % at the optimal condition. Therefore, the developed prototype single-stage anaerobic digester can be highly promising for university canteen application to recover energy from food wastes via biogas production.

  18. Reactive Power Control of Single-Stage Three-Phase Photovoltaic System during Grid Faults Using Recurrent Fuzzy Cerebellar Model Articulation Neural Network

    Directory of Open Access Journals (Sweden)

    Faa-Jeng Lin

    2014-01-01

    Full Text Available This study presents a new active and reactive power control scheme for a single-stage three-phase grid-connected photovoltaic (PV system during grid faults. The presented PV system utilizes a single-stage three-phase current-controlled voltage-source inverter to achieve the maximum power point tracking (MPPT control of the PV panel with the function of low voltage ride through (LVRT. Moreover, a formula based on positive sequence voltage for evaluating the percentage of voltage sag is derived to determine the ratio of the injected reactive current to satisfy the LVRT regulations. To reduce the risk of overcurrent during LVRT operation, a current limit is predefined for the injection of reactive current. Furthermore, the control of active and reactive power is designed using a two-dimensional recurrent fuzzy cerebellar model articulation neural network (2D-RFCMANN. In addition, the online learning laws of 2D-RFCMANN are derived according to gradient descent method with varied learning-rate coefficients for network parameters to assure the convergence of the tracking error. Finally, some experimental tests are realized to validate the effectiveness of the proposed control scheme.

  19. A simulation study on performance evaluation of single-stage LiBr–H2O vapor absorption heat pump for chip cooling

    Directory of Open Access Journals (Sweden)

    Manu S.

    2016-12-01

    Full Text Available The growth of Lithium Bromide–Water (LiBr–H2O absorption based heat pump is encouraged for the necessity of extracting high heat from the electronic chips. This paper presents a simulation study of single-stage LiBr–H2O vapor absorption heat pump for chip cooling. In this study, a detailed thermodynamic analysis of the single-stage LiBr–H2O vapor absorption heat pump for chip cooling in the nonexistence of solution heat exchanger was performed and a user-friendly graphical user interface (GUI package including visual components was developed by using MATlab (2008b. The influence of chip temperature on COP (Coefficient of Performance, flow rates and conductance was examined by using the developed package. The model is validated by using the values available in the literature and indicates that there is a greater reduction in the absorber load. The influence of chip temperature on the performance and thermal loads of individual components was studied and it was concluded that, COP increases from 0.7145 to 0.8421 with an increase in chip temperature.

  20. Analysis of honeybush tea (Cyclopia spp.) volatiles by comprehensive two-dimensional gas chromatography using a single-stage thermal modulator.

    Science.gov (United States)

    Ntlhokwe, Gaalebalwe; Tredoux, Andreas G J; Górecki, Tadeusz; Edwards, Matthew; Vestner, Jochen; Muller, Magdalena; Erasmus, Lené; Joubert, Elizabeth; Christel Cronje, J; de Villiers, André

    2017-07-01

    The applicability of comprehensive two-dimensional gas chromatography (GC×GC) using a single-stage thermal modulator was explored for the analysis of honeybush tea (Cyclopia spp.) volatile compounds. Headspace solid phase micro-extraction (HS-SPME) was used in combination with GC×GC separation on a non-polar × polar column set with flame ionisation (FID) detection for the analysis of fermented Cyclopia maculata, Cyclopia subternata and Cyclopia genistoides tea infusions of a single harvest season. Method optimisation entailed evaluation of the effects of several experimental parameters on the performance of the modulator, the choice of columns in both dimensions, as well as the HS-SPME extraction fibre. Eighty-four volatile compounds were identified by co-injection of reference standards. Principal component analysis (PCA) showed clear differentiation between the species based on their volatile profiles. Due to the highly reproducible separations obtained using the single-stage thermal modulator, multivariate data analysis was simplified. The results demonstrate both the complexity of honeybush volatile profiles and the potential of GC×GC separation in combination with suitable data analysis techniques for the investigation of the relationship between sensory properties and volatile composition of these products. The developed method therefore offers a fast and inexpensive methodology for the profiling of honeybush tea volatiles. Graphical abstract Surface plot obtained for the GC×GC-FID analysis of honeybush tea volatiles.

  1. The performance of a trickle-bed reactor packed with a Pt/SDBC catalyst mixture for the CECE process

    Energy Technology Data Exchange (ETDEWEB)

    Paek, Seungwoo [Korea Atomic Energy Research Institute, 150 Deokjin-dong, Yuseong-gu, Daejeon 305-353 (Korea, Republic of)], E-mail: swpaek@kaeri.re.kr; Ahn, Do-Hee; Choi, Heui-Joo; Kim, Kwang-Rag; Lee, Minsoo; Yim, Sung-Paal; Chung, Hongsuk [Korea Atomic Energy Research Institute, 150 Deokjin-dong, Yuseong-gu, Daejeon 305-353 (Korea, Republic of); Song, Kyu-Min; Sohn, Soon Hwan [Korea Electric Power Research Institute, 103-16 Munji-dong, Yuseong-gu, Daejeon 305-380 (Korea, Republic of)

    2007-10-15

    The combined electrolysis and catalytic exchange (CECE) process with a hydrophobic catalyst is a very effective method to remove small quantities of tritium from light or heavy wastewater streams because of its high separation factor and mild operating conditions. A hydrophobic platinum/styrene-divinyl benzene copolymer (Pt/SDBC) catalyst which was developed for the liquid-phase catalytic exchange (LPCE) column of the Wolsong tritium removal facility (WTRF) has been tested in a trickle bed reactor for the design of the CECE process. An experimental apparatus has been built for the testing of the catalyst at various temperatures and gas velocities. The catalyst column was packed with a mixture of a hydrophobic catalyst and a hydrophilic packing (Dixon gauze ring) to improve the liquid distribution and vapor/liquid transfer area. Many tests have been carried out at Korea Atomic Energy Research Institute (KAERI) to measure the activity of the catalyst, K{sub y}a (1 s{sup -1}), under various operating conditions. K{sub y}a increases with the hydrogen flow rates in the range of 0.4-1.6 m s{sup -1} at STP. The height of the catalyst column was determined from these K{sub y}a values according to the reaction temperatures and hydrogen flow rates.

  2. A two-stage combined trickle bed reactor/biofilter for treatment of styrene/acetone vapor mixtures.

    Science.gov (United States)

    Vanek, Tomas; Halecky, Martin; Paca, Jan; Zapotocky, Lubos; Gelbicova, Tereza; Vadkertiova, Renata; Kozliak, Evguenii; Jones, Kim

    2015-01-01

    Performance of a two-stage biofiltration system was investigated for removal of styrene-acetone mixtures. High steady-state acetone loadings (above C(in)(Ac) = 0.5 g.m(-3) corresponding to the loadings > 34.5 g.m(-3).h(-1)) resulted in a significant inhibition of the system's performance in both acetone and styrene removal. This inhibition was shown to result from the acetone accumulation within the upstream trickle-bed bioreactor (TBR) circulating mineral medium, which was observed by direct chromatographic measurements. Placing a biofilter (BF) downstream to this TBR overcomes the inhibition as long as the biofilter has a sufficient bed height. A different kind of inhibition of styrene biodegradation was observed within the biofilter at very high acetone loadings (above C(in)(Ac) = 1.1 g.m(-3) or 76 g.m(-3).h(-1) loading). In addition to steady-state measurements, dynamic tests confirmed that the reactor overloading can be readily overcome, once the accumulated acetone in the TBR fluids is degraded. No sizable metabolite accumulation in the medium was observed for either TBR or BF. Analyses of the biodegradation activities of microbial isolates from the biofilm corroborated the trends observed for the two-stage biofiltration system, particularly the occurrence of an inhibition threshold by excess acetone.

  3. Investigation of flow dynamics of liquid phase in a pilot-scale trickle bed reactor using radiotracer technique.

    Science.gov (United States)

    Pant, H J; Sharma, V K

    2016-10-01

    A radiotracer investigation was carried out to measure residence time distribution (RTD) of liquid phase in a trickle bed reactor (TBR). The main objectives of the investigation were to investigate radial and axial mixing of the liquid phase, and evaluate performance of the liquid distributor/redistributor at different operating conditions. Mean residence times (MRTs), holdups (H) and fraction of flow flowing along different quadrants were estimated. The analysis of the measured RTD curves indicated radial non-uniform distribution of liquid phase across the beds. The overall RTD of the liquid phase, measured at the exit of the reactor was simulated using a multi-parameter axial dispersion with exchange model (ADEM), and model parameters were obtained. The results of model simulations indicated that the TBR behaved as a plug flow reactor at most of the operating conditions used in the investigation. The results of the investigation helped to improve the existing design as well as to design a full-scale industrial TBR for petroleum refining applications. Copyright © 2016 Elsevier Ltd. All rights reserved.

  4. Digital filters

    CERN Document Server

    Hamming, Richard W

    1997-01-01

    Digital signals occur in an increasing number of applications: in telephone communications; in radio, television, and stereo sound systems; and in spacecraft transmissions, to name just a few. This introductory text examines digital filtering, the processes of smoothing, predicting, differentiating, integrating, and separating signals, as well as the removal of noise from a signal. The processes bear particular relevance to computer applications, one of the focuses of this book.Readers will find Hamming's analysis accessible and engaging, in recognition of the fact that many people with the s

  5. Biogas biodesulfurization in an anoxic biotrickling filter packed with open-pore polyurethane foam.

    Science.gov (United States)

    Fernández, Maikel; Ramírez, Martín; Gómez, José Manuel; Cantero, Domingo

    2014-01-15

    Biogas biodesulfurization by an anoxic biotrickling filter packed with open pore polyurethane foam at the laboratory scale (packed volume 2.4L) has been studied. The biotrickling system was operated for 620 days with biogas supplied continuously and two nitrate feeding regimes were tested (manual and programmed). Biomass immobilization was carried out under the manual nitrate feeding regime and a study was then carried out on the effects on removal efficiency of the following parameters: nitrate source, H2S inlet load, nitrate concentration, sulfate accumulation, temperature, pH and trickling liquid velocity. The effect of increased H2S inlet load was studied under the programmed nitrate feeding regime. The results show that a removal efficiency of 99% can be obtained when working under the following conditions: inlet loads below 130gSm(-3)h(-1), a programmed nitrate feeding system, temperature of 30°C, sulfate concentration below 33gL(-1), a pH between 7.3 and 7.5, and a trickling liquid velocity higher than 4.6mh(-1). Copyright © 2013 Elsevier B.V. All rights reserved.

  6. A Proposal Of Simulation Model Of A Wind-Steering System For Sailing Yachts, Based On Single-Stage Servo-Pendulum Coupled With Main Rudder

    Directory of Open Access Journals (Sweden)

    Piętak Andrzej

    2015-04-01

    Full Text Available The aim of this study was to investigate possible application of fast design prototyping methods for wind-steering systems used in offshore sailing yachts. The development of such methods would help to speed up the construction work and reduce the scope of necessary experimental research, prior to implementation of the system. In the present work, based on an analysis of existing designs of windvane systems, a preliminary selection of the system configuration has been undertaken, in terms of a compromise between efficiency, performance, and design complexity. Construction design of a single-stage, servo – pendulum system, has been developed by using the Autodesk Inventor design package. Next, based on the design data, a simulation model of the system, has been produced by using Matlab - Simulink software and SimMechanics library. The model was further verified in terms of kinematics mapping with the use of Matlab visualization tools.

  7. Single Stage String Inverter for Gridconnected Photovoltaic System with Modified Perturb and Observe (P&O Fuzzy Logic Control(FLC-based MPPT Technique

    Directory of Open Access Journals (Sweden)

    S.Z.Mohammad Noor

    2016-06-01

    Full Text Available This paper presents an implementation of Single-phase Single stage String inverter for Grid connected Photovoltaic (PV system. The proposed system uses Modified Perturb and Observe (P&O algorithm implemented using Fuzzy Logic Control (FLC as Maximum Power Point Tracking (MPPT. The inverter is designed for 340W system using two series of STP170s24/Ac PV modules. The MPPT unit keeps tracking the maximum power from the PV array by changing the modulation index and the phase angle of inverter’s output voltage. The simulation model is developed using Matlab/Simulink to evaluate the performance of the converter. Selected experimental results are also presented in this paper.

  8. Performance comparison of single-stage mixed-refrigerant Joule–Thomson cycle and reverse Brayton cycle for cooling 80 to 120 K temperature-distributed heat loads

    Science.gov (United States)

    Wang, H. C.; Chen, G. F.; Gong, M. Q.; Li, X.

    2017-12-01

    Thermodynamic performance comparison of single-stage mixed-refrigerant Joule–Thomson cycle (MJTR) and pure refrigerant reverse Brayton cycle (RBC) for cooling 80 to 120 K temperature-distributed heat loads was conducted in this paper. Nitrogen under various liquefaction pressures was employed as the heat load. The research was conducted under nonideal conditions by exergy analysis methods. Exergy efficiency and volumetric cooling capacity are two main evaluation parameters. Exergy loss distribution in each process of refrigeration cycle was also investigated. The exergy efficiency and volumetric cooling capacity of MJTR were obviously superior to RBC in 90 to 120 K temperature zone, but still inferior to RBC at 80 K. The performance degradation of MJTR was caused by two main reasons: The high fraction of neon resulted in large entropy generation and exergy loss in throttling process. Larger duty and WLMTD lead to larger exergy losses in recuperator.

  9. Evaluation of advanced hydraulic turbomachinery for underground pumped hydroelectric storage. Part 1. Single-stage regulated pump turbines for operating heads of 500 to 1000 m

    Energy Technology Data Exchange (ETDEWEB)

    Frigo, A.A.; Blomquist, C.A.; Degnan, J.R.

    1979-10-01

    High-head, large-capacity turbomachinery is needed for the concept of underground pumped hydroelectric storage to be technically and economically attractive. Single-stage, reversible, Francis-type pump turbines with adjustable wicket gates appear to offer the most economically attractive option for heads between about 500 and 1000 m. The feasibility of developing these types of machines for capacities up to 500 MW and operating heads up to 1000 m has been evaluated. Preliminary designs have been generated for six single-stage pump turbines. The designs are for capacities of 350 and 500 MW and for operating heads of 500, 750, and 1000 m. The report contains drawings of the machines along with material specifications and hydraulic performance data. Mechanical, hydraulic, and economic analyses indicate that these machines will behave according to the criteria used to design them and that they can be built at a reasonable cost. The stress and deflection responses of the 500-MW, 100-m-head pump turbine, determined by detailed finite element analysis techniques, give solid evidence of the integrity of the conceptual designs of the six units and indicate no unsolvable problems. Results of a life expectancy analysis of the wicket gates indicate that a near infinite life can be expected for these components when they are subjected to normal design loads. Efficiencies of 90.7 and 91.4% in the generating and pumping modes, respectively, can be expected for the 500-MW, 1000-m-head unit. Performances of the other five machines are comparable. The specific costs of the pump turbines in mid-1978 US dollars per kW vary from 19.2 to 11.8 over a head range of from 500 to 1000 m for the 500-MW machines and from 20.0 to 12.3 for the 350-MW machines.

  10. In-source collision-induced dissociation (IS-CID): Applications, issues and structure elucidation with single-stage mass analyzers.

    Science.gov (United States)

    Parcher, Jon F; Wang, Mei; Chittiboyina, Amar G; Khan, Ikhlas A

    2018-01-01

    A discussion of the definition, advantages, and issues with the formation of ions in the transition region between an electrospray ionization (ESI) source and the ion optics of a mass analyzer is presented. The various types of ions formed in the so-called in-source collision-induced dissociation (IS-CID) process are illustrated. Applications of IS-CID with single-stage mass analyzers, such as structure elucidation and quantitation, are demonstrated. The discussion is illustrated by examples of the in-source fragmentation of ginkgolides, which are marker compounds found only in Ginkgo biloba. Supercritical fluid chromatography (SFC) with non-aqueous eluents was used to achieve a fast resolution of the ginkgolides without the hydrolysis reactions possible with aqueous high-performance liquid chromatography (HPLC) eluents. In-source ion generation occurs at relatively high pressures (ca. 1-3 torr) compared to the low pressure normally observed in collision chambers of tandem mass spectrometry (MS/MS). As a result, the fragmentation process is complex and often generates ions other than the fragments observed with classic CID or the same ions at different intensities. The objective of the current tutorial is to illustrate the conditions under which single-stage, quadrupole or time-of-flight mass analyzers with electrospray or in-air (direct analysis in real time; DART) ionization can be used for quantitation and structure elucidation in a manner similar to that observed with MS/MS. While the low m/z (≤ [M±H] ± ) ions formed in-source often duplicate the ions observed in MS/MS systems, it is the focus of this discussion to illustrate the utility of in-source generated fragment ions that may not be observed or observed at different intensities than in the collision cells of MS/MS instruments. Copyright © 2017 John Wiley & Sons, Ltd.

  11. Efficacy of single-stage breast-conserving treatment using multicatheter partial breast brachytherapy evaluated by GEC-ESTRO phase 3 trial.

    Science.gov (United States)

    Sato, Kazuhiko; Fuchikami, Hiromi; Kato, Masahiro; Shimo, Takahiro; Kubota, Jun; Takeda, Naoko; Inoue, Yuko; Seto, Hiroshi; Okawa, Tomohiko

    2017-10-01

    The GEC-ESTRO has reported the equivalent outcomes of partial breast irradiation (PBI) using multicatheter interstitial brachytherapy (MCB) to whole breast irradiation (WBI) in breast-conserving therapy (BCT). We performed single-stage BCT with partial breast brachytherapy by intraoperative catheter placement. After the categorization of patients into inclusion and exclusion criteria on this trial, our databases were evaluated in order to translate it to Japanese patients. Patients undergoing BCT were retrospectively examined between November 2007 and December 2015. The technique is an open-cavity implant with a dose of 32 Gy in 8 fractions. The 4-year clinical outcomes of MCB-PBI were evaluated in the 2 distinct categories, and the comparison of the outcomes of MCB-PBI with WBI was performed in patients with unfavorable features. Of a total of 501 lesions undergoing BCT, 301 lesions were treated with MCB-PBI and 200 lesions with WBI. At the median follow-up time of 52 months, the 4-year rate of ipsilateral breast tumor recurrence (IBTR)-free, disease-free (DFS), and overall survival (OS) in patients with MCB-PBI and WBI were 98.9% vs. 98.0% ( p = 0.56), 97.0% vs. 95.3% ( p = 0.78), and 99.6% vs. 98.2% ( p = 0.38), respectively. Although in exclusion cohort treated with MCB-PBI, IBTR-free, and disease-free survival were significantly worse than in inclusion cohort, non-significantly worse outcomes was demonstrated than in exclusion cohort with WBI; IBTR-free survival (95.0% vs. 97.2%, p = 0.24), and disease-free survival (95.0% vs. 95.8%, p = 0.31). Single-stage BCT using MCB-PBI offered similar tumor control rates compering to WBI. However, further research is needed to define the benefit for patients with an exclusion criteria.

  12. Single-stage multilevel soft-tissue surgery in the lower limbs with spastic cerebral palsy: Experience from a rehabilitation unit

    Directory of Open Access Journals (Sweden)

    Gupta Anupam

    2008-01-01

    Full Text Available Background: To assess the effect of single-stage multilevel soft-tissue surgery (Single Event Multiple Level Resections, SEMLR on deformities and locomotion in patients with cerebral palsy (CP with static contracture(s in lower limbs. Patients and Methods: Study included 34 patients (M:F, 23:11 with mean age of 9.53 ± 3.92 years (4-16 years. Among them 22 had diplegia and four each had quadriplegia and right and left hemiplegia. Fourteen patients (41.2% had their intelligence quotient (IQ in the normal range (IQ ≥ 80, while others had mental retardation (MR of varying severity: borderline MR (IQ = 70-79 in 12, mild MR (IQ = 50-69 in 5, and moderate MR (IQ = 35-49 in patients 3. All patients underwent surgery (total number of procedures 153, average 4.5 procedures/patient over a period of 30 months (April 2005 to September 2007. Improvement in functional abilities and locomotion was assessed using Gross Motor Functional Classification Scale (GMFCS scores and by physical examination. Results: Significant improvement in function was observed ( P = 0.000 after surgery when comparing the preoperative and postoperative GMFCS scores. All patients were maintaining ambulation at a mean follow-up duration of 13.12 ± 6.07 months (3-24 months, with five patients using knee-ankle-foot orthoses (KAFO, 22 using ankle-foot orthoses (AFO, and six patients using knee gaiters. Sixteen patients were using walker, and two were using crutches as assistive devices. Conclusion: This study suggests that CP patients with good trunk control and static contractures at multiple joints in the lower limbs can be made ambulant with single-stage multilevel soft-tissue surgery. It has to be a team effort of the surgeon and the rehabilitation team in the postoperative period for the attainment of satisfactory goal.

  13. In Vivo Evaluation of Vena Caval Filters: Can Function Be Linked to Design Characteristics?

    International Nuclear Information System (INIS)

    Proctor, Mary C.; Cho, Kyung J.; Greenfield, Lazar J.

    2000-01-01

    Purpose: To compare the five vena caval filters marketed in the United States and one investigational vena caval filter and to determine whether there is an association between their design and their in vivo function.Methods: Four of each type of filter-Simon Nitinol (SN), Bird's Nest (BN), Vena Tech (VT), Greenfield stainless steel (PSGF), Greenfield titanium (TGF), and the investigational stent cone filter (NGF)-were studied for 60 days in 12 sheep. Radiographic and pathologic outcomes to be assessed included clot capture and resolution, vena caval penetration, position of the filter, thrombogenicity, and vessel wall reaction.Results: Filters differed with respect to the number of clot-trapping levels and the interdependence of the legs. All devices were successfully placed. Intentionally embolized clot was captured. One VT and two SN filters migrated in response to clot capture. Resolution of thrombus was variable, and related to the design of the device. Fibrin webbing was widely present with the VT, BN, and SN filters but limited in the others. The VT and NGF filters demonstrated the most stable filter base diameter.Conclusions: The performance of vena caval filters differs with respect to clot resolution and mechanical stability. Interdependent filter limbs and single-stage conical capture sites appear to result in more favorable performance in in vivo studies

  14. Nitrification in trickling filters applied to the post-treatment of effluents from UASB reactor: correlation between ammonia removal and the relative abundance of nitrifying bacteria

    International Nuclear Information System (INIS)

    Missagia, B. S.; Almeida, P. G. S. de; Silva, S. Q.; Chernicharo, C. A. L.

    2009-01-01

    The number and physiological activity of nitrifying bacteria in wastewater treatment reactors are considered the ratelimiting parameters for the bioconversion of nitrogen in sewage. Since the presence of ammonia and nitrite oxidizers can be correlated with their activity. In situ probe counts can be correlated with the nitrification rates in order to compare the efficiency of different media types. (Author)

  15. Nitrification in trickling filters applied to the post-treatment of effluents from UASB reactor: correlation between ammonia removal and the relative abundance of nitrifying bacteria

    Energy Technology Data Exchange (ETDEWEB)

    Missagia, B. S.; Almeida, P. G. S. de; Silva, S. Q.; Chernicharo, C. A. L.

    2009-07-01

    The number and physiological activity of nitrifying bacteria in wastewater treatment reactors are considered the ratelimiting parameters for the bioconversion of nitrogen in sewage. Since the presence of ammonia and nitrite oxidizers can be correlated with their activity. In situ probe counts can be correlated with the nitrification rates in order to compare the efficiency of different media types. (Author)

  16. X-ray digital industrial radiography (DIR) for local liquid velocity (VLL) measurement in trickle bed reactors (TBRs): Validation of the technique

    Science.gov (United States)

    Mohd Salleh, Khairul Anuar; Rahman, Mohd Fitri Abdul; Lee, Hyoung Koo; Al Dahhan, Muthanna H.

    2014-06-01

    Local liquid velocity measurements in Trickle Bed Reactors (TBRs) are one of the essential components in its hydrodynamic studies. These measurements are used to effectively determine a reactor's operating condition. This study was conducted to validate a newly developed technique that combines Digital Industrial Radiography (DIR) with Particle Tracking Velocimetry (PTV) to measure the Local Liquid Velocity (VLL) inside TBRs. Three millimeter-sized Expanded Polystyrene (EPS) beads were used as packing material. Three validation procedures were designed to test the newly developed technique. All procedures and statistical approaches provided strong evidence that the technique can be used to measure the VLL within TBRs.

  17. Single-stage osseointegrated reconstruction and rehabilitation of lower limb amputees: the Osseointegration Group of Australia Accelerated Protocol-2 (OGAAP-2) for a prospective cohort study.

    Science.gov (United States)

    Al Muderis, Munjed; Lu, William; Tetsworth, Kevin; Bosley, Belinda; Li, Jiao Jiao

    2017-03-22

    Lower limb amputations have detrimental influences on the quality of life, function and body image of the affected patients. Following amputation, prolonged rehabilitation is required for patients to be fitted with traditional socket prostheses, and many patients experience symptomatic socket-residuum interface problems which lead to reduced prosthetic use and quality of life. Osseointegration has recently emerged as a novel approach for the reconstruction of amputated limbs, which overcomes many of the socket-related problems by directly attaching the prosthesis to the skeletal residuum. To date, the vast majority of osseointegration procedures worldwide have been performed in 2 stages, which require at least 4 months and up to 18 months for the completion of reconstruction and rehabilitation from the time of the initial surgery. The current prospective cohort study evaluates the safety and efficacy of a single-stage osseointegration procedure performed under the Osseointegration Group of Australia Accelerated Protocol-2 (OGAAP-2), which dramatically reduces the time of recovery to ∼3-6 weeks. The inclusion criteria for osseointegrated reconstruction under the OGAAP-2 procedure are age over 18 years, unilateral transfemoral amputation and experiencing problems or difficulties in using socket prostheses. All patients receive osseointegrated implants which are press-fitted into the residual bone. Functional and quality-of-life outcome measures are recorded preoperatively and at defined postoperative follow-up intervals up to 2 years. Postoperative adverse events are also recorded. The preoperative and postoperative values are compared for each outcome measure, and the benefits and harms of the single-stage OGAAP-2 procedure will be compared with the results obtained using a previously employed 2-stage procedure. This study has received ethics approval from the University of Notre Dame, Sydney, Australia (014153S). The study outcomes will be disseminated

  18. Laser cellulite treatment and laser-assisted lipoplasty of the thighs and buttocks: Combined modalities for single stage contouring of the lower body.

    Science.gov (United States)

    Petti, Christine; Stoneburner, Jacqueline; McLaughlin, Laura

    2016-01-01

    Cellulite and lipodystrophy are often found together, especially in areas of the buttocks and thighs, causing skin surface irregularities. Each of these conditions is currently treated independently as two separate surgical procedures. In our practice, we developed a novel combined approach for the simultaneous treatment of cellulite and lipodystrophy, as a single stage procedure in the same anatomic area. For the treatment of cellulite, we used the Nd:YAG laser at a wavelength of 1,440-nm, along with an innovative 1,000-micron directional side-firing fiber optic laser system. For the treatment of lipodystrophy, the Nd:YAG laser with a 1,440 nm wavelength, along with a fiber optic laser system was used. The objective of this study is to determine the efficacy and safety of a combined approach for the simultaneous treatment of cellulite and lipodystrophy. In 2012, 16 subjects with noticeable cellulite, Grade II and Grade III, accompanied by mild-to-moderate lipodystrophy of the lower body received single treatments of the Nd:YAG laser at a wavelength of 1,440-nm along with the 1,000-micron side-firing fiber optic laser system for simultaneous treatments of both cellulite and lipodystrophy. Patients were assessed at baseline and 3-6 months post-treatment by a modified Nurnberger-Muller scale utilized to quantify the cellulite severity. Additionally, patient satisfaction and a global aesthetic improvement scale were used to measure the improvement in lipodystrophy. Blinded reviewers identified the correct baseline photographs 97% of the time when presented with a set of photographs. The median modified Nurnberger-Muller scale score at baseline was 4.75 ± 1.2 and the average improvement was 2.0 ± 1.2. Global aesthetic improvement scores ranged from 1 to 3 with an average of 1.58 indicating a much-improved overall appearance. Satisfaction was high for both physicians and patients with scores corresponding to extremely satisfied/satisfied. Precise, effective

  19. Immediate, single stage, truly anatomic zirconia implant in lower molar replacement: a case report with 2.5 years follow-up.

    Science.gov (United States)

    Pirker, W; Wiedemann, D; Lidauer, A; Kocher, A A

    2011-02-01

    This report demonstrates the clinical use of a modified, truly anatomic, root-analogue zirconia implant for immediate replacement of a two-rooted, left first mandibular molar. A 50-year-old female patient with chronic apical periodontitis of the left mandibulary first molar was referred and the tooth was extracted. The mesial root had to be removed surgically due to a root fracture. A truly anatomical, root identical, roughened zirconia implant modified by macro-retentions was manufactured and placed into the extraction socket by tapping 7 days later. After 4 months a composite crown was cemented in place. No complications occurred during the healing period. A good functional and aesthetic result was achieved with minimal bone resorption and soft tissue recession at 30 months follow-up. This report describes the successful clinical use of an immediate, single stage, truly anatomical root-analogue zirconia implant for replacement of a two-rooted tooth. Significant modifications such as macro-retentions yielded primary stability and excellent osseointegration. This novel approach is minimally invasive, respects the underlying anatomy, aids socket prevention, is time- and cost-saving with good patient acceptance as there is no need for bone drilling, sinus lift, bone augmentation or other traumatic procedures. Copyright © 2010 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  20. Enhancement of the complete autotrophic nitrogen removal over nitrite process in a modified single-stage subsurface vertical flow constructed wetland: Effect of saturated zone depth.

    Science.gov (United States)

    Huang, Menglu; Wang, Zhen; Qi, Ran

    2017-06-01

    This study was conducted to explore enhancement of the complete autotrophic nitrogen removal over nitrite (CANON) process in a modified single-stage subsurface vertical flow constructed wetland (VSSF) with saturated zone, and nitrogen transformation pathways in the VSSF treating digested swine wastewater were investigated at four different saturated zone depths (SZDs). SZD significantly affected nitrogen transformation pathways in the VSSF throughout the experiment. As the SZD was 45cm, the CANON process was enhanced most effectively in the system owing to the notable enhancement of anammox. Correspondingly, the VSSF had the best TN removal performance [(76.74±7.30)%] and lower N 2 O emission flux [(3.50±0.22)mg·(m 2 ·h) - 1 ]. It could be concluded that autotrophic nitrogen removal via CANON process could become a primary route for nitrogen removal in the VSSF with optimized microenvironment that developed as a result of the appropriate SZD. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. High flux coherent super-continuum soft X-ray source driven by a single-stage, 10mJ, Ti:sapphire amplifier-pumped OPA.

    Science.gov (United States)

    Ding, Chengyuan; Xiong, Wei; Fan, Tingting; Hickstein, Daniel D; Popmintchev, Tenio; Zhang, Xiaoshi; Walls, Mike; Murnane, Margaret M; Kapteyn, Henry C

    2014-03-10

    We demonstrate the highest flux tabletop source of coherent soft X-rays to date, driven by a single-stage 10 mJ Ti:sapphire regenerative amplifier at 1 kHz. We first down-convert the laser to 1.3 µm using a parametric amplifier, before up-converting it to soft X-rays using high harmonic generation in a high-pressure, phase matched, hollow waveguide geometry. The resulting optimally phase matched broadband spectrum extends to 200 eV, with a soft X-ray photon flux of > 10(6) photons/pulse/1% bandwidth at 1 kHz, corresponding to > 10(9) photons/s/1% bandwidth, or approximately a three order-of-magnitude increase compared with past work. Finally, using this broad bandwidth X-ray source, we demonstrate X-ray absorption spectroscopy of multiple elements and transitions in molecules in a single spectrum, with a spectral resolution of 0.25 eV, and with the ability to resolve the near edge fine structure.

  2. Multi-analysis determination of tropane alkaloids in cereals and solanaceaes seeds by liquid chromatography coupled to single stage Exactive-Orbitrap.

    Science.gov (United States)

    Marín-Sáez, Jesús; Romero-González, Roberto; Garrido Frenich, Antonia

    2017-10-06

    Tropane alkaloids are a wide group of substances that comprises more than 200 compounds occurring especially in the Solanaceae family. The main aim of this study is the development of a method for the analysis of the principal tropane alkaloids as atropine, scopolamine, anisodamine, tropane, tropine, littorine, homatropine, apoatropine, aposcopolamine, scopoline, tropinone, physoperuvine, pseudotropine and cuscohygrine in cereals and related matrices. For that, a simple solid-liquid extraction was optimized and a liquid chromatographic method coupled to a single stage Exactive-Orbitrap was developed. The method was validated obtaining recoveries in the range of 60-109% (except for some compounds in soy), precision values (expressed as relative standard deviation) lower than 20% and detection and quantification limits equal to or lower than 2 and 3μg/kg respectively. Finally, the method was applied to the analysis of different types of samples as buckwheat, linseed, soy and millet, obtaining positives for anisodamine, scopolamine, atropine, littorine and tropinone in a millet flour sample above the quantification limits, whereas atropine and scopolamine were detected in a buckwheat sample, below the quantification limit. Contaminated samples with Solanaceaes seeds (Datura Stramonium and Brugmansia Arborea) were also analysed, detecting concentrations up to 693μg/kg (scopolamine) for contaminated samples with Brugmansia seeds and 1847μg/kg (atropine) when samples were contaminated with Stramonium seeds. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Performance analysis of single stage libr-water absorption machine operated by waste thermal energy of internal combustion engine: Case study

    Science.gov (United States)

    Sharif, Hafiz Zafar; Leman, A. M.; Muthuraman, S.; Salleh, Mohd Najib Mohd; Zakaria, Supaat

    2017-09-01

    Combined heating, cooling, and power is also known as Tri-generation. Tri-generation system can provide power, hot water, space heating and air -conditioning from single source of energy. The objective of this study is to propose a method to evaluate the characteristic and performance of a single stage lithium bromide-water (LiBr-H2O) absorption machine operated with waste thermal energy of internal combustion engine which is integral part of trigeneration system. Correlations for computer sensitivity analysis are developed in data fit software for (P-T-X), (H-T-X), saturated liquid (water), saturated vapor, saturation pressure and crystallization temperature curve of LiBr-H2O Solution. Number of equations were developed with data fit software and exported into excel work sheet for the evaluation of number of parameter concerned with the performance of vapor absorption machine such as co-efficient of performance, concentration of solution, mass flow rate, size of heat exchangers of the unit in relation to the generator, condenser, absorber and evaporator temperatures. Size of vapor absorption machine within its crystallization limits for cooling and heating by waste energy recovered from exhaust gas, and jacket water of internal combustion engine also presented in this study to save the time and cost for the facilities managers who are interested to utilize the waste thermal energy of their buildings or premises for heating and air conditioning applications.

  4. Serum antibody responses in pigs trickle-infected with Ascaris and Trichuris: Heritabilities and associations with parasitological findings.

    Science.gov (United States)

    Kringel, Helene; Thamsborg, Stig Milan; Petersen, Heidi Huus; Göring, Harald Heinz Herbert; Skallerup, Per; Nejsum, Peter

    2015-07-30

    A humoral immune response following helminth infection in pigs is well documented. However, it has been difficult to confirm the existence of antibody mediated resistance against the large roundworm, Ascaris suum, and whipworm, Trichuris suis, in experimental settings by correlating worm burdens or egg excretion with specific antibody levels. We set out to investigate the association between worm load and T. suis and A. suum specific serum antibody levels (IgG1, IgG2 and IgA) against excretory-secretory products of adults and third stage larvae, respectively, measured at 0, 7 and 14 weeks p.i. in a trickle-infected F1-resource-population of crossbred pigs (n=195). Furthermore, we wanted to determine the heritability of these antibody isotypes during the course of infection. Most pigs remained infected with A. suum throughout the experiment while they expelled T. suis between 7 and 14 weeks post infection (p.i.). Parasite specific IgG1 and IgA were significantly (P<0.001) elevated after 7 and 14 weeks of infection, whereas parasite specific IgG2 levels only changed slightly at 14 weeks p.i.. However, the observed association between specific antibody isotype levels and faecal egg counts and macroscopic worm load was weak. The relative heritabilities of the different parasite specific isotypes were assessed and resulted in significant heritability estimates for parasite specific IgG1 and IgA. The highest heritabilities were found for A. suum specific IgG1 (h(2)=0.41 and 0.46 at 7 and 14 weeks p.i., respectively). Thus, the present study demonstrates that host genetic factors influence the IgG1 and IgA antibody isotype responses specific to two of the most common gastrointestinal nematodes of swine whereas specific antibody levels were poorly associated with egg excretion and the presence of macroscopic worms. Copyright © 2015. Published by Elsevier B.V.

  5. Optimized FIR filters for digital pulse compression of biphase codes with low sidelobes

    Science.gov (United States)

    Sanal, M.; Kuloor, R.; Sagayaraj, M. J.

    In miniaturized radars where power, real estate, speed and low cost are tight constraints and Doppler tolerance is not a major concern biphase codes are popular and FIR filter is used for digital pulse compression (DPC) implementation to achieve required range resolution. Disadvantage of low peak to sidelobe ratio (PSR) of biphase codes can be overcome by linear programming for either single stage mismatched filter or two stage approach i.e. matched filter followed by sidelobe suppression filter (SSF) filter. Linear programming (LP) calls for longer filter lengths to obtain desirable PSR. Longer the filter length greater will be the number of multipliers, hence more will be the requirement of logic resources used in the FPGAs and many time becomes design challenge for system on chip (SoC) requirement. This requirement of multipliers can be brought down by clustering the tap weights of the filter by kmeans clustering algorithm at the cost of few dB deterioration in PSR. The cluster centroid as tap weight reduces logic used in FPGA for FIR filters to a great extent by reducing number of weight multipliers. Since k-means clustering is an iterative algorithm, centroid for weights cluster is different in different iterations and causes different clusters. This causes difference in clustering of weights and sometimes even it may happen that lesser number of multiplier and lesser length of filter provide better PSR.

  6. Passive Power Filters

    CERN Document Server

    Künzi, R.

    2015-06-15

    Power converters require passive low-pass filters which are capable of reducing voltage ripples effectively. In contrast to signal filters, the components of power filters must carry large currents or withstand large voltages, respectively. In this paper, three different suitable filter struc tures for d.c./d.c. power converters with inductive load are introduced. The formulas needed to calculate the filter components are derived step by step and practical examples are given. The behaviour of the three discussed filters is compared by means of the examples. P ractical aspects for the realization of power filters are also discussed.

  7. Filter replacement lifetime prediction

    Science.gov (United States)

    Hamann, Hendrik F.; Klein, Levente I.; Manzer, Dennis G.; Marianno, Fernando J.

    2017-10-25

    Methods and systems for predicting a filter lifetime include building a filter effectiveness history based on contaminant sensor information associated with a filter; determining a rate of filter consumption with a processor based on the filter effectiveness history; and determining a remaining filter lifetime based on the determined rate of filter consumption. Methods and systems for increasing filter economy include measuring contaminants in an internal and an external environment; determining a cost of a corrosion rate increase if unfiltered external air intake is increased for cooling; determining a cost of increased air pressure to filter external air; and if the cost of filtering external air exceeds the cost of the corrosion rate increase, increasing an intake of unfiltered external air.

  8. Exergy analysis of an experimental single-stage heat transformer operating with single water/lithium bromide and using additives (1-octanol and 2-ethyl-1-hexanol)

    International Nuclear Information System (INIS)

    Rivera, W.; Martinez, H.; Cerezo, J.; Romero, R.J.; Cardoso, M.J.

    2011-01-01

    Second law of Thermodynamics has been used to analyze the performance of an experimental single-stage heat transformer operating with the water/lithium bromide as single working pair and subsequently, using 1-octanol and 2-ethyl-1-hexanol as additives. Additives have been used in order to increase the heat transfer in the absorber and generator decreasing their irreversibilities. The enthalpy-based coefficients of performance (COP), external coefficients of performance (COP EXT ), exergy-based coefficients of performance (ECOP) and the irreversibilities of the equipment components were calculated for the main operating temperatures of the system. The results showed that for absorber temperatures between 84 o C and 88 o C the highest COP, COP EXT , and ECOP are obtained with the use of the 2-ethyl-1-hexanol (400 parts per million) additive, reaching values up to 0.49, 0.40 and 0.43, respectively. The lowest coefficients of performance and highest irreversibilities were obtained by using the single water/lithium bromide mixture. Analysing the irreversibilities in each one of the main components of the system, it was found that 2-ethyl-1-hexanol decreases considerably the irreversibility in the absorber then increasing the efficiency of this component and hence of the entire equipment. - Highlights: → An exergy analysis has been used to analyze an experimental heat transformer. → The system operated with single water/lithium bromide and then adding two additives. → The additives were 1-octanol and 2-ethyl-1-hexanol. → The 2-ethyl-1-hexanol additive reduced the system irreversibilities. → The highest coefficients of performance were obtained with the 2-ethyl-1-hexanol additive.

  9. Evaluation of a single-stage consumable-free modulator for comprehensive two-dimensional gas chromatography: analysis of polychlorinated biphenyls, organochlorine pesticides and chlorobenzenes.

    Science.gov (United States)

    Muscalu, Alina M; Edwards, Matthew; Górecki, Tadeusz; Reiner, Eric J

    2015-04-24

    Comprehensive two-dimensional gas chromatography (GC×GC) has been rapidly growing in popularity. The GC×GC separation is performed by interfacing a modulator between two columns of different selectivities. The modulator periodically traps and then re-injects the analytes eluting from the first column into the second column. The most popular GC×GC systems require consumables such as liquid N2 for the trapping function of the modulator. Although these systems are very effective, their costs are a hindrance to more widespread use. A new, single-stage thermal modulator for GC×GC that requires no consumables has been developed and tested. The device traps analytes using a proprietary stainless steel capillary trap compressed between two ceramic cooling pads. Analytes are thermally desorbed from the trap into the second column via resistive heating. To evaluate this system, a routine accredited method for the analysis of polychlorinated biphenyls, organochlorine pesticides and chlorobenzenes was run using the new modulator and its performance was compared to that of an industry standard modulation system. Within-day repeatability (% RSD ranging from 2% to 13%), between-day reproducibility (% RSD from 3% to 15%), as well as between-trap reproducibility were assessed. The results are very encouraging as negligible shifts in retention times (% RSD from 0.3% to 0.6% in the 1st dimension and 0.8% to 2% in the 2nd dimension) were observed for both within-day and day-to-day comparisons of the studied samples (ANOVA, p=0.9893 for the sediment reference material compared), and the quantitative results were comparable. Routine analysis and quality control applications will benefit from the improved reproducibility as the variances in cold/hot jet flows and temperatures are eliminated. An overview of the device operation and the results from this study are summarized. Copyright © 2015 Elsevier B.V. All rights reserved.

  10. A Collaborative Analysis Tool for Integrating Hypersonic Aerodynamics, Thermal Protection Systems, and RBCC Engine Performance for Single Stage to Orbit Vehicles

    Science.gov (United States)

    Stanley, Thomas Troy; Alexander, Reginald

    1999-01-01

    Presented is a computer-based tool that connects several disciplines that are needed in the complex and integrated design of high performance reusable single stage to orbit (SSTO) vehicles. Every system is linked to every other system, as is the case of SSTO vehicles with air breathing propulsion, which is currently being studied by NASA. The deficiencies in the scramjet powered concept led to a revival of interest in Rocket-Based Combined-Cycle (RBCC) propulsion systems. An RBCC propulsion system integrates airbreathing and rocket propulsion into a single engine assembly enclosed within a cowl or duct. A typical RBCC propulsion system operates as a ducted rocket up to approximately Mach 3. At this point the transitions to a ramjet mode for supersonic-to-hypersonic acceleration. Around Mach 8 the engine transitions to a scram4jet mode. During the ramjet and scramjet modes, the integral rockets operate as fuel injectors. Around Mach 10-12 (the actual value depends on vehicle and mission requirements), the inlet is physically closed and the engine transitions to an integral rocket mode for orbit insertion. A common feature of RBCC propelled vehicles is the high degree of integration between the propulsion system and airframe. At high speeds the vehicle forebody is fundamentally part of the engine inlet, providing a compression surface for air flowing into the engine. The compressed air is mixed with fuel and burned. The combusted mixture must be expanded to an area larger than the incoming stream to provide thrust. Since a conventional nozzle would be too large, the entire lower after body of the vehicle is used as an expansion surface. Because of the high external temperatures seen during atmospheric flight, the design of an airbreathing SSTO vehicle requires delicate tradeoffs between engine design, vehicle shape, and thermal protection system (TPS) sizing in order to produce an optimum system in terms of weight (and cost) and maximum performance.

  11. Influence of Different Tibial Fixation Techniques on Initial Stability in Single-Stage Anterior Cruciate Ligament Revision With Confluent Tibial Tunnels: A Biomechanical Laboratory Study.

    Science.gov (United States)

    Schliemann, Benedikt; Treder, Maximilian; Schulze, Martin; Müller, Viktoria; Vasta, Sebastiano; Zampogna, Biaggio; Herbort, Mirco; Kösters, Clemens; Raschke, Michael J; Lenschow, Simon

    2016-01-01

    To kinematically and biomechanically compare 4 different types of tibial tunnel management in single-stage anterior cruciate ligament (ACL) revision reconstruction with the control: primary ACL reconstruction using a robotic-based knee testing setup. Porcine knees and flexor tendons were used. One hundred specimens were randomly assigned to 5 testing groups: (1) open tibial tunnel, (2) bone plug technique, (3) biodegradable interference screw, (4) dilatation technique, and (5) primary ACL reconstruction. A robotic/universal force-moment sensor testing system was used to simulate the KT-1000 (MEDmetric, San Diego, CA) and pivot-shift tests. Cyclic loading and load-to-failure testing were performed. Anterior tibial translation increased significantly with all of the techniques compared with the intact ACL (P .05). The open tunnel and dilated tunnel techniques showed significantly greater anterior tibial translation (P < .05). The results of the simulated pivot-shift test were in accordance with those of the KT-1000 test. No significant differences could be observed regarding stiffness or maximum load to failure. However, elongation was significantly lower in the primary ACL reconstruction group compared with groups 1 and 3 (P = .02 and P = .03, respectively). Filling an incomplete and incorrect tibial tunnel with a press-fit bone plug or a biodegradable interference screw in a standardized laboratory situation provided initial biomechanical properties and knee stability comparable with those of primary ACL reconstruction. In contrast, the dilatation technique or leaving the malplaced tunnel open did not restore knee kinematics adequately in this model. Backup extracortical fixation should be considered because the load to failure depends on the extracortical fixation when an undersized interference screw is used for aperture fixation. Our biomechanical results could help orthopaedic surgeons to optimize the results of primary ACL revision with incomplete, incorrect

  12. Post-Burn Skin Deformities of the Face and Neck Region in Pediatric Patients: Single-Stage Treatment Using Collagen Elastin Matrix

    Directory of Open Access Journals (Sweden)

    Çağlayan Yağmur

    2017-09-01

    Full Text Available Objective: Treating severe post-burn deformities of the face and neck region in pediatric populations is challenging because of technical difficulties (e.g., limited full thickness skin graft donor site, limited flap options, unavailability for expander placement and increased donor site morbidity (e.g., related to flap and graft donor sites. In this study, we present the single-stage treatment of severe post-burn skin deformities of the face and neck region in pediatric patients using collagen-elastin matrix (Matriderm® combined with partial thickness skin grafts. Material and Methods: The total number of cases was eight (four females, four males, and the ages were between two and 11 years. All cases were operated on for only one region. Following the release of contractures and/or excision of wide excessive/ unfavorable dermal scars, defects were reconstructed using collagen- elastin matrix (Matriderm® combined with partial-thickness skin grafts. The final functional and aesthetic results were evaluated using photography and examination. Results: The deformities were in the form of contractures and/ or excessive dermal scarring. The involved regions were the face (n=3 and neck (n=5. The grafts yielded favorable plication and texture, and no recurrence of excessive dermal scarring was observed. All contractures healed unproblematically. Two patients were re-operated on for regrafting caused by minor graft loss (5% and 12% of the total area, respectively. Conclusion: In this study, we observed that collagen elastin matrix combined with partial-thickness skin grafts provides a favorable option for the treatment of pediatric late post-burn complications in the face and neck region with limited surgical options.

  13. Tap water filters.

    Science.gov (United States)

    2003-02-01

    Moen PureTouch filters remove impurities from tap water without removing fluoride. These carbon block filters consist of finely powdered activated carbon that is combined with a plastic binder material and heated to form a hollow cylinder. The blocks are further wrapped with material to improve performance and reduce clogging. The filters are available with different filtering capabilities (Table 1). The filters mount in the faucet spout or under the sink.

  14. Design of multichannel DWDM fiber Bragg grating filters by Lagrange multiplier constrained optimization.

    Science.gov (United States)

    Lee, Cheng-Ling; Lee, Ray-Kuang; Kao, Yee-Mou

    2006-11-13

    We present the synthesis of multi-channel fiber Bragg grating (MCFBG) filters for dense wavelength-division-multiplexing (DWDM) application by using a simple optimization approach based on a Lagrange multiplier optimization (LMO) method. We demonstrate for the first time that the LMO method can be used to constrain various parameters of the designed MCFBG filters for practical application demands and fabrication requirements. The designed filters have a number of merits, i.e., flat-top and low dispersion spectral response as well as single stage. Above all, the maximum amplitude of the index modulation profiles of the designed MCFBGs can be substantially reduced under the applied constrained condition. The simulation results demonstrate that the LMO algorithm can provide a potential alternative for complex fiber grating filter design problems.

  15. Modelagem e simulação de um reator trickle-bed para hidrogenação de propeno

    OpenAIRE

    Rodrigo Simion Hunger

    2002-01-01

    Neste trabalho foi modelado um reator catalítico heterogêneo, pressurizado, adiabático e provido de reciclo. O leito deste reator está dividido em duas partes, sendo que a primeira opera como um reator trickle-bed, enquanto a segunda opera como um reator de leito fixo, onde os regentes estão em fase líquida. Um Sistema de Hidrogenação de Propeno em operação no Pólo Petroquímico do Sul foi utilizado para fornecer os dados necessários à validação do modelo proposto. Neste sistema, a reação de h...

  16. Catalytic wet air oxidation of bisphenol A solution in a batch-recycle trickle-bed reactor over titanate nanotube-based catalysts.

    Science.gov (United States)

    Kaplan, Renata; Erjavec, Boštjan; Senila, Marin; Pintar, Albin

    2014-10-01

    Catalytic wet air oxidation (CWAO) is classified as an advanced oxidation process, which proved to be highly efficient for the removal of emerging organic pollutant bisphenol A (BPA) from water. In this study, BPA was successfully removed in a batch-recycle trickle-bed reactor over bare titanate nanotube-based catalysts at very short space time of 0.6 min gCAT g(-1). The as-prepared titanate nanotubes, which underwent heat treatment at 600 °C, showed high activity for the removal of aqueous BPA. Liquid-phase recycling (5- or 10-fold recycle) enabled complete BPA conversion already at 200 °C, together with high conversion of total organic carbon (TOC), i.e., 73 and 98 %, respectively. The catalyst was chemically stable in the given range of operating conditions for 189 h on stream.

  17. Quantitative targeted and retrospective data analysis of relevant pesticides, antibiotics and mycotoxins in bakery products by liquid chromatography-single-stage Orbitrap mass spectrometry.

    Science.gov (United States)

    De Dominicis, Emiliano; Commissati, Italo; Gritti, Elisa; Catellani, Dante; Suman, Michele

    2015-01-01

    In addition to 'traditional' multi-residue and multi-contaminant multiple reaction monitoring (MRM) mass spectrometric techniques devoted to quantifying a list of targeted compounds, the global food industry requires non-targeted methods capable of detecting other possible potentially hazardous compounds. Ultra-high-performance liquid chromatography combined with a single-stage Orbitrap high-resolution mass spectrometer (UHPLC-HRMS Exactive™-Orbitrap Technology) was successfully exploited for the complete selective and quantitative determination of 33 target compounds within three major cross categories (pesticides, antibiotics and mycotoxins) in bakery matrices (specifically milk, wheat flour and mini-cakes). Resolution was set at 50 000 full width at half maximum (FWHM) to achieve the right compromise between an adequate scan speed and selectivity, allowing for the limitations related to the necessary generic sample preparation approach. An exact mass with tolerance of 5 ppm and minimum peak threshold of 10 000 units were fixed as the main identification conditions, including retention time and isotopic pattern as additional criteria devoted to greatly reducing the risk of false-positive findings. The full validation for all the target analytes was performed: linearity, intermediate repeatability and recovery (28 analytes within 70-120%) were positively assessed; furthermore, limits of quantification between 5 and 100 µg kg(-1) (with most of the analytes having a limit of detection below 6 µg kg(-1)) indicate good performance, which is compatible with almost all the regulatory needs. Naturally contaminated and fortified mini-cakes, prepared through combined use of industrial and pilot plant production lines, were analysed at two different concentration levels, obtaining good overall quantitative results and providing preliminary indications of the potential of full-scan HRMS cluster analysis. The effectiveness of this analytical approach was also tested in

  18. HEPA Filter Vulnerability Assessment

    International Nuclear Information System (INIS)

    GUSTAVSON, R.D.

    2000-01-01

    This assessment of High Efficiency Particulate Air (HEPA) filter vulnerability was requested by the USDOE Office of River Protection (ORP) to satisfy a DOE-HQ directive to evaluate the effect of filter degradation on the facility authorization basis assumptions. Within the scope of this assessment are ventilation system HEPA filters that are classified as Safety-Class (SC) or Safety-Significant (SS) components that perform an accident mitigation function. The objective of the assessment is to verify whether HEPA filters that perform a safety function during an accident are likely to perform as intended to limit release of hazardous or radioactive materials, considering factors that could degrade the filters. Filter degradation factors considered include aging, wetting of filters, exposure to high temperature, exposure to corrosive or reactive chemicals, and exposure to radiation. Screening and evaluation criteria were developed by a site-wide group of HVAC engineers and HEPA filter experts from published empirical data. For River Protection Project (RPP) filters, the only degradation factor that exceeded the screening threshold was for filter aging. Subsequent evaluation of the effect of filter aging on the filter strength was conducted, and the results were compared with required performance to meet the conditions assumed in the RPP Authorization Basis (AB). It was found that the reduction in filter strength due to aging does not affect the filter performance requirements as specified in the AB. A portion of the HEPA filter vulnerability assessment is being conducted by the ORP and is not part of the scope of this study. The ORP is conducting an assessment of the existing policies and programs relating to maintenance, testing, and change-out of HEPA filters used for SC/SS service. This document presents the results of a HEPA filter vulnerability assessment conducted for the River protection project as requested by the DOE Office of River Protection

  19. HEPA filter monitoring program

    Science.gov (United States)

    Kirchner, K. N.; Johnson, C. M.; Aiken, W. F.; Lucerna, J. J.; Barnett, R. L.; Jensen, R. T.

    1986-07-01

    The testing and replacement of HEPA filters, widely used in the nuclear industry to purify process air, are costly and labor-intensive. Current methods of testing filter performance, such as differential pressure measurement and scanning air monitoring, allow determination of overall filter performance but preclude detection of incipient filter failure such as small holes in the filters. Using current technology, a continual in-situ monitoring system was designed which provides three major improvements over current methods of filter testing and replacement. The improvements include: cost savings by reducing the number of intact filters which are currently being replaced unnecessarily; more accurate and quantitative measurement of filter performance; and reduced personnel exposure to a radioactive environment by automatically performing most testing operations.

  20. Bias aware Kalman filters

    DEFF Research Database (Denmark)

    Drecourt, J.-P.; Madsen, H.; Rosbjerg, Dan

    2006-01-01

    This paper reviews two different approaches that have been proposed to tackle the problems of model bias with the Kalman filter: the use of a colored noise model and the implementation of a separate bias filter. Both filters are implemented with and without feedback of the bias into the model state...... are illustrated on a simple one-dimensional groundwater problem. The results show that the presented filters outperform the standard Kalman filter and that the implementations with bias feedback work in more general conditions than the implementations without feedback. 2005 Elsevier Ltd. All rights reserved........ The colored noise filter formulation is extended to correct both time correlated and uncorrelated model error components. A more stable version of the separate filter without feedback is presented. The filters are implemented in an ensemble framework using Latin hypercube sampling. The techniques...

  1. UV holographic filters

    Science.gov (United States)

    Kalyashova, Zoya N.

    2017-11-01

    A new approach to UV holographic filter's manufacturing, when the filters are the volume reflection holograms, working in UV region in the second Bragg diffraction order, is offered. The method is experimentally realized for wavelength of 266 nm.

  2. MST Filterability Tests

    Energy Technology Data Exchange (ETDEWEB)

    Poirier, M. R. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Burket, P. R. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Duignan, M. R. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2015-03-12

    The Savannah River Site (SRS) is currently treating radioactive liquid waste with the Actinide Removal Process (ARP) and the Modular Caustic Side Solvent Extraction Unit (MCU). The low filter flux through the ARP has limited the rate at which radioactive liquid waste can be treated. Recent filter flux has averaged approximately 5 gallons per minute (gpm). Salt Batch 6 has had a lower processing rate and required frequent filter cleaning. Savannah River Remediation (SRR) has a desire to understand the causes of the low filter flux and to increase ARP/MCU throughput. In addition, at the time the testing started, SRR was assessing the impact of replacing the 0.1 micron filter with a 0.5 micron filter. This report describes testing of MST filterability to investigate the impact of filter pore size and MST particle size on filter flux and testing of filter enhancers to attempt to increase filter flux. The authors constructed a laboratory-scale crossflow filter apparatus with two crossflow filters operating in parallel. One filter was a 0.1 micron Mott sintered SS filter and the other was a 0.5 micron Mott sintered SS filter. The authors also constructed a dead-end filtration apparatus to conduct screening tests with potential filter aids and body feeds, referred to as filter enhancers. The original baseline for ARP was 5.6 M sodium salt solution with a free hydroxide concentration of approximately 1.7 M.3 ARP has been operating with a sodium concentration of approximately 6.4 M and a free hydroxide concentration of approximately 2.5 M. SRNL conducted tests varying the concentration of sodium and free hydroxide to determine whether those changes had a significant effect on filter flux. The feed slurries for the MST filterability tests were composed of simple salts (NaOH, NaNO2, and NaNO3) and MST (0.2 – 4.8 g/L). The feed slurry for the filter enhancer tests contained simulated salt batch 6 supernate, MST, and filter enhancers.

  3. Updating the OMERACT filter

    DEFF Research Database (Denmark)

    Kirwan, John R; Boers, Maarten; Hewlett, Sarah

    2014-01-01

    OBJECTIVE: The Outcome Measures in Rheumatology (OMERACT) Filter provides guidelines for the development and validation of outcome measures for use in clinical research. The "Truth" section of the OMERACT Filter presupposes an explicit framework for identifying the relevant core outcomes that are......OBJECTIVE: The Outcome Measures in Rheumatology (OMERACT) Filter provides guidelines for the development and validation of outcome measures for use in clinical research. The "Truth" section of the OMERACT Filter presupposes an explicit framework for identifying the relevant core outcomes...

  4. Oriented Fiber Filter Media

    OpenAIRE

    R. Bharadwaj; A. Patel, S. Chokdeepanich, Ph.D.; G.G. Chase, Ph.D.

    2008-01-01

    Coalescing filters are widely used throughout industry and improved performance will reduce droplet emissions and operating costs. Experimental observations show orientation of micro fibers in filter media effect the permeability and the separation efficiency of the filter media. In this work two methods are used to align the fibers to alter the filter structure. The results show that axially aligned fiber media improve quality factor on the order of 20% and cutting media on an angle from a t...

  5. HEPA filter encapsulation

    Science.gov (United States)

    Gates-Anderson, Dianne D.; Kidd, Scott D.; Bowers, John S.; Attebery, Ronald W.

    2003-01-01

    A low viscosity resin is delivered into a spent HEPA filter or other waste. The resin is introduced into the filter or other waste using a vacuum to assist in the mass transfer of the resin through the filter media or other waste.

  6. Filter service system

    Science.gov (United States)

    Sellers, Cheryl L [Peoria, IL; Nordyke, Daniel S [Arlington Heights, IL; Crandell, Richard A [Morton, IL; Tomlins, Gregory [Peoria, IL; Fei, Dong [Peoria, IL; Panov, Alexander [Dunlap, IL; Lane, William H [Chillicothe, IL; Habeger, Craig F [Chillicothe, IL

    2008-12-09

    According to an exemplary embodiment of the present disclosure, a system for removing matter from a filtering device includes a gas pressurization assembly. An element of the assembly is removably attachable to a first orifice of the filtering device. The system also includes a vacuum source fluidly connected to a second orifice of the filtering device.

  7. Analysis and demonstration of single-passband response and tuning characteristics in a chirped ladder interferometric filter for a widely tunable laser diode.

    Science.gov (United States)

    Jeong, Seok-Hwan; Matsuo, Shinji; Yoshikuni, Yuzo; Segawa, Toru; Ohiso, Yoshitaka; Suzuki, Hiroyuki

    2005-10-01

    We have designed and demonstrated a chirped ladder-type tunable filter and discussed its potential application for a tunable diode laser. A ladder interferometric filter normally has a periodic passband, which makes it impossible to stabilize laser oscillation frequency. To overcome this drawback, we have designed, fabricated, and characterized a novel chirped tunable ladder filter. We have successfully demonstrated a single-passband response in the fabricated device. Furthermore, a tuning operation of more than 30 nm was achieved by introducing a current injection structure and optimizing electrode lengths at each single-stage ladder interferometer.

  8. Balanced microwave filters

    CERN Document Server

    Hong, Jiasheng; Medina, Francisco; Martiacuten, Ferran

    2018-01-01

    This book presents and discusses strategies for the design and implementation of common-mode suppressed balanced microwave filters, including, narrowband, wideband, and ultra-wideband filters This book examines differential-mode, or balanced, microwave filters by discussing several implementations of practical realizations of these passive components. Topics covered include selective mode suppression, designs based on distributed and semi-lumped approaches, multilayer technologies, defect ground structures, coupled resonators, metamaterials, interference techniques, and substrate integrated waveguides, among others. Divided into five parts, Balanced Microwave Filters begins with an introduction that presents the fundamentals of balanced lines, circuits, and networks. Part 2 covers balanced transmission lines with common-mode noise suppression, including several types of common-mode filters and the application of such filters to enhance common-mode suppression in balanced bandpass filters. Next, Part 3 exa...

  9. Exhaust gas filter

    International Nuclear Information System (INIS)

    Wada, Tadamasa; Hiraki, Akimitsu.

    1993-01-01

    A filter material formed by joining glass clothes to both surfaces of a glass fiber non-woven fabric is used. The filter material is disposed at the inside of a square filter material support frame made of stainless steel. The filter material is attached in a zig-zag manner in the flowing direction of the exhaust gases so as to increase the filtration area. Separators, for example, made of stainless steel are inserted between the filter materials. The separator is corrugated so as to sandwich and support the filter materials from both sides by the ridged crests. The longitudinal bottom of the separator formed by corrugating it defines a flow channel of the exhaustion gases. The longitudinal bottom is also used as a channel for back blowing air. With such a constitution, combustion gases of radioactive miscellaneous solid wastes can be completely filtered. In addition, a back wash can be conducted under high temperature. (I.N.)

  10. Changing ventilation filters

    International Nuclear Information System (INIS)

    Hackney, S.

    1980-01-01

    A filter changing unit has a door which interlocks with the door of a filter chamber so as to prevent contamination of the outer surfaces of the doors by radioactive material collected on the filter element and a movable support which enables a filter chamber thereonto to be stored within the unit in such a way that the doors of the unit and the filter chamber can be replaced. The door pivots and interlocks with another door by means of a bolt, a seal around the periphery lip of the first door engages the periphery of the second door to seal the gap. A support pivots into a lower filter element storage position. Inspection windows and glove ports are provided. The unit is releasably connected to the filter chamber by bolts engaging in a flange provided around an opening. (author)

  11. Single-staged resections and 3D reconstructions of the nasion, glabella, medial orbital wall, and frontal sinus and bone: Long-term outcome and review of the literature.

    Science.gov (United States)

    Ciporen, Jeremy; Lucke-Wold, Brandon P; Mendez, Gustavo; Chen, Anton; Banerjee, Amit; Akins, Paul T; Balough, Ben J

    2016-01-01

    Aesthetic facial appearance following neurosurgical ablation of frontal fossa tumors is a primary concern for patients and neurosurgeons alike. Craniofacial reconstruction procedures have drastically evolved since the development of three-dimensional computed tomography imaging and computer-assisted programming. Traditionally, two-stage approaches for resection and reconstruction were used; however, these two-stage approaches have many complications including cerebrospinal fluid leaks, necrosis, and pneumocephalus. We present two successful cases of single-stage osteoma resection and craniofacial reconstruction in a 26-year-old female and 65-year-old male. The biopolymer implants were preselected and contoured based on imaging prior to surgery. The ideal selection of appropriate flaps for reconstruction was imperative. The flaps were well vascularized and included a pedicle for easy translocation. Using a titanium mesh biopolymer implant for reconstruction in conjunction with a forehead flap proved advantageous, and the benefits of single-stage approaches were apparent. The patients recovered quickly after the surgery with complete resection of the osteoma and good aesthetic appearance. The flap adhered to the biopolymer implant, and the cosmetic appearance years after surgery remained decent. The gap between the bone and implant was less than 2 mm. The patients are highly satisfied with the symmetrical appearance of the reconstruction. Advances in technology are allowing neurosurgeons unprecedented opportunities to design complex yet feasible single-stage craniofacial reconstructions that improve a patient's quality of life by enhancing facial contours, aesthetics, and symmetry.

  12. Filter material charging apparatus for filter assembly for radioactive contaminants

    International Nuclear Information System (INIS)

    Goldsmith, J.M.; O'Nan, A. Jr.

    1977-01-01

    A filter charging apparatus for a filter assembly is described. The filter assembly includes a housing with at least one filter bed therein and the filter charging apparatus for adding filter material to the filter assembly includes a tank with an opening therein, the tank opening being disposed in flow communication with opposed first and second conduit means, the first conduit means being in flow communication with the filter assembly housing and the second conduit means being in flow communication with a blower means. Upon activation of the blower means, the blower means pneumatically conveys the filter material from the tank to the filter housing

  13. The diffuse ensemble filter

    Directory of Open Access Journals (Sweden)

    X. Yang

    2009-07-01

    Full Text Available A new class of ensemble filters, called the Diffuse Ensemble Filter (DEnF, is proposed in this paper. The DEnF assumes that the forecast errors orthogonal to the first guess ensemble are uncorrelated with the latter ensemble and have infinite variance. The assumption of infinite variance corresponds to the limit of "complete lack of knowledge" and differs dramatically from the implicit assumption made in most other ensemble filters, which is that the forecast errors orthogonal to the first guess ensemble have vanishing errors. The DEnF is independent of the detailed covariances assumed in the space orthogonal to the ensemble space, and reduces to conventional ensemble square root filters when the number of ensembles exceeds the model dimension. The DEnF is well defined only in data rich regimes and involves the inversion of relatively large matrices, although this barrier might be circumvented by variational methods. Two algorithms for solving the DEnF, namely the Diffuse Ensemble Kalman Filter (DEnKF and the Diffuse Ensemble Transform Kalman Filter (DETKF, are proposed and found to give comparable results. These filters generally converge to the traditional EnKF and ETKF, respectively, when the ensemble size exceeds the model dimension. Numerical experiments demonstrate that the DEnF eliminates filter collapse, which occurs in ensemble Kalman filters for small ensemble sizes. Also, the use of the DEnF to initialize a conventional square root filter dramatically accelerates the spin-up time for convergence. However, in a perfect model scenario, the DEnF produces larger errors than ensemble square root filters that have covariance localization and inflation. For imperfect forecast models, the DEnF produces smaller errors than the ensemble square root filter with inflation. These experiments suggest that the DEnF has some advantages relative to the ensemble square root filters in the regime of small ensemble size, imperfect model, and copious

  14. Generic Kalman Filter Software

    Science.gov (United States)

    Lisano, Michael E., II; Crues, Edwin Z.

    2005-01-01

    The Generic Kalman Filter (GKF) software provides a standard basis for the development of application-specific Kalman-filter programs. Historically, Kalman filters have been implemented by customized programs that must be written, coded, and debugged anew for each unique application, then tested and tuned with simulated or actual measurement data. Total development times for typical Kalman-filter application programs have ranged from months to weeks. The GKF software can simplify the development process and reduce the development time by eliminating the need to re-create the fundamental implementation of the Kalman filter for each new application. The GKF software is written in the ANSI C programming language. It contains a generic Kalman-filter-development directory that, in turn, contains a code for a generic Kalman filter function; more specifically, it contains a generically designed and generically coded implementation of linear, linearized, and extended Kalman filtering algorithms, including algorithms for state- and covariance-update and -propagation functions. The mathematical theory that underlies the algorithms is well known and has been reported extensively in the open technical literature. Also contained in the directory are a header file that defines generic Kalman-filter data structures and prototype functions and template versions of application-specific subfunction and calling navigation/estimation routine code and headers. Once the user has provided a calling routine and the required application-specific subfunctions, the application-specific Kalman-filter software can be compiled and executed immediately. During execution, the generic Kalman-filter function is called from a higher-level navigation or estimation routine that preprocesses measurement data and post-processes output data. The generic Kalman-filter function uses the aforementioned data structures and five implementation- specific subfunctions, which have been developed by the user on

  15. A Collaborative Analysis Tool for Integrated Hypersonic Aerodynamics, Thermal Protection Systems, and RBCC Engine Performance for Single Stage to Orbit Vehicles

    Science.gov (United States)

    Stanley, Thomas Troy; Alexander, Reginald; Landrum, Brian

    2000-01-01

    Presented is a computer-based tool that connects several disciplines that are needed in the complex and integrated design of high performance reusable single stage to orbit (SSTO) vehicles. Every system is linked to every other system, as is the case of SSTO vehicles with air breathing propulsion, which is currently being studied by NASA. An RBCC propulsion system integrates airbreathing and rocket propulsion into a single engine assembly enclosed within a cowl or duct. A typical RBCC propulsion system operates as a ducted rocket up to approximately Mach 3. Then there is a transition to a ramjet mode for supersonic-to-hypersonic acceleration. Around Mach 8 the engine transitions to a scramjet mode. During the ramjet and scramjet modes, the integral rockets operate as fuel injectors. Around Mach 10-12 (the actual value depends on vehicle and mission requirements), the inlet is physically closed and the engine transitions to an integral rocket mode for orbit insertion. A common feature of RBCC propelled vehicles is the high degree of integration between the propulsion system and airframe. At high speeds the vehicle forebody is fundamentally part of the engine inlet, providing a compression surface for air flowing into the engine. The compressed air is mixed with fuel and burned. The combusted mixture must be expanded to an area larger than the incoming stream to provide thrust. Since a conventional nozzle would be too large, the entire lower after body of the vehicle is used as an expansion surface. Because of the high external temperatures seen during atmospheric flight, the design of an airbreathing SSTO vehicle requires delicate tradeoffs between engine design, vehicle shape, and thermal protection system (TPS) sizing in order to produce an optimum system in terms of weight (and cost) and maximum performance. To adequately determine the performance of the engine/vehicle, the Hypersonic Flight Inlet Model (HYFIM) module was designed to interface with the RBCC

  16. Hybrid Filter Membrane

    Science.gov (United States)

    Laicer, Castro; Rasimick, Brian; Green, Zachary

    2012-01-01

    Cabin environmental control is an important issue for a successful Moon mission. Due to the unique environment of the Moon, lunar dust control is one of the main problems that significantly diminishes the air quality inside spacecraft cabins. Therefore, this innovation was motivated by NASA s need to minimize the negative health impact that air-suspended lunar dust particles have on astronauts in spacecraft cabins. It is based on fabrication of a hybrid filter comprising nanofiber nonwoven layers coated on porous polymer membranes with uniform cylindrical pores. This design results in a high-efficiency gas particulate filter with low pressure drop and the ability to be easily regenerated to restore filtration performance. A hybrid filter was developed consisting of a porous membrane with uniform, micron-sized, cylindrical pore channels coated with a thin nanofiber layer. Compared to conventional filter media such as a high-efficiency particulate air (HEPA) filter, this filter is designed to provide high particle efficiency, low pressure drop, and the ability to be regenerated. These membranes have well-defined micron-sized pores and can be used independently as air filters with discreet particle size cut-off, or coated with nanofiber layers for filtration of ultrafine nanoscale particles. The filter consists of a thin design intended to facilitate filter regeneration by localized air pulsing. The two main features of this invention are the concept of combining a micro-engineered straight-pore membrane with nanofibers. The micro-engineered straight pore membrane can be prepared with extremely high precision. Because the resulting membrane pores are straight and not tortuous like those found in conventional filters, the pressure drop across the filter is significantly reduced. The nanofiber layer is applied as a very thin coating to enhance filtration efficiency for fine nanoscale particles. Additionally, the thin nanofiber coating is designed to promote capture of

  17. Variational Bayesian Filtering

    Czech Academy of Sciences Publication Activity Database

    Šmídl, Václav; Quinn, A.

    2008-01-01

    Roč. 56, č. 10 (2008), s. 5020-5030 ISSN 1053-587X R&D Projects: GA MŠk 1M0572 Institutional research plan: CEZ:AV0Z10750506 Keywords : Bayesian filtering * particle filtering * Variational Bayes Subject RIV: BC - Control Systems Theory Impact factor: 2.335, year: 2008 http://library.utia.cas.cz/separaty/2008/AS/smidl-variational bayesian filtering.pdf

  18. Nanofiber Filters Eliminate Contaminants

    Science.gov (United States)

    2009-01-01

    With support from Phase I and II SBIR funding from Johnson Space Center, Argonide Corporation of Sanford, Florida tested and developed its proprietary nanofiber water filter media. Capable of removing more than 99.99 percent of dangerous particles like bacteria, viruses, and parasites, the media was incorporated into the company's commercial NanoCeram water filter, an inductee into the Space Foundation's Space Technology Hall of Fame. In addition to its drinking water filters, Argonide now produces large-scale nanofiber filters used as part of the reverse osmosis process for industrial water purification.

  19. Independent task Fourier filters

    Science.gov (United States)

    Caulfield, H. John

    2001-11-01

    Since the early 1960s, a major part of optical computing systems has been Fourier pattern recognition, which takes advantage of high speed filter changes to enable powerful nonlinear discrimination in `real time.' Because filter has a task quite independent of the tasks of the other filters, they can be applied and evaluated in parallel or, in a simple approach I describe, in sequence very rapidly. Thus I use the name ITFF (independent task Fourier filter). These filters can also break very complex discrimination tasks into easily handled parts, so the wonderful space invariance properties of Fourier filtering need not be sacrificed to achieve high discrimination and good generalizability even for ultracomplex discrimination problems. The training procedure proceeds sequentially, as the task for a given filter is defined a posteriori by declaring it to be the discrimination of particular members of set A from all members of set B with sufficient margin. That is, we set the threshold to achieve the desired margin and note the A members discriminated by that threshold. Discriminating those A members from all members of B becomes the task of that filter. Those A members are then removed from the set A, so no other filter will be asked to perform that already accomplished task.

  20. Randomized Filtering Algorithms

    DEFF Research Database (Denmark)

    Katriel, Irit; Van Hentenryck, Pascal

    2008-01-01

    of AllDifferent and is generalization, the Global Cardinality Constraint. The first delayed filtering scheme is a Monte Carlo algorithm: its running time is superior, in the worst case, to that of enforcing are consistency after every domain event, while its filtering effectiveness is analyzed......Filtering every global constraint of a CPS to are consistency at every search step can be costly and solvers often compromise on either the level of consistency or the frequency at which are consistency is enforced. In this paper we propose two randomized filtering schemes for dense instances...

  1. Enhanced performance configuration for fast-switching deformed helix ferroelectric liquid crystal continuous tunable Lyot filter.

    Science.gov (United States)

    Tam, A M W; Qi, G; Srivastava, A K; Wang, X Q; Fan, F; Chigrinov, V G; Kwok, H S

    2014-06-10

    In this paper, we present a novel design configuration of double DHFLC wave plate continuous tunable Lyot filter, which exhibits a rapid response time of 185 μs, while the high-contrast ratio between the passband and stop band is maintained throughout a wide tunable range. A DHFLC tunable filter with a high-contrast ratio is attractive for realizing high-speed optical processing devices, such as multispectral and hyperspectral imaging systems, real-time remote sensing, field sequential color display, and wavelength demultiplexing in the metro network. In this work, an experimental prototype for a single-stage DHFLC Lyot filter of this design has been fabricated using photoalignment technology. We have demonstrated that the filter has a continuous tunable range of 30 nm for a blue wavelength, 45 nm for a green wavelength, and more than 50 nm for a red wavelength when the applied voltage gradually increases from 0 to 8 V. Within this tunable range, the contrast ratio of the proposed double wave plate configuration is maintained above 20 with small deviation in the transmittance level. Simulation and experimental results showed the proposed double DHFLC wave plate configuration enhances the contrast ratio of the tunable filter and, thus, increases the tunable range of the filter when compared with the Lyot filter using a single DHFLC wave plate. Moreover, we have proposed a polarization insensitive configuration for which the efficiency of the existing prototype can theoretically be doubled by the use of polarization beam splitters.

  2. Multilevel ensemble Kalman filter

    KAUST Repository

    Chernov, Alexey

    2016-01-06

    This work embeds a multilevel Monte Carlo (MLMC) sampling strategy into the Monte Carlo step of the ensemble Kalman filter (EnKF). In terms of computational cost vs. approximation error the asymptotic performance of the multilevel ensemble Kalman filter (MLEnKF) is superior to the EnKF s.

  3. Interdigital filter design

    CSIR Research Space (South Africa)

    Du Plessis, WP

    2009-10-01

    Full Text Available A new synthesis procedure for interdigital filters with shorted-pin feeds is developed by relating the coupling factors and external Qs to the physical structure of the filter. This new procedure is easily understood and applied, extremely flexible...

  4. Structural adjustment programs and the trickle-down effect: a case study of the Fujimori period in Peru, using reproductive health as an indicator for levels of poverty.

    Science.gov (United States)

    Menon, Sonia Simone

    2007-12-01

    The purpose of this analysis is to investigate whether the Organisation for Economic Co-operation and Development/United Nations/World Bank (OECD/UN/WB) poverty reduction objectives are compatible with the neo-liberal development model, using Peru as a case study. Three OECD/UN reproductive health indicators were selected to assess poverty: female literacy, infant mortality and maternal mortality. Fertility rates were also analyzed to explore the impact that neo-Malthusian policies have wielded. Shortly after his ascendance to power in 1990, President Fujimori undertook health finance reforms to promote cost-effectiveness and efficiency under political guidance from international financial institutions (IFIs). Internationally, Peru was portrayed as a neo-liberal success story. However, maternal mortality rates throw into contention claims that economic growth has a trickle-down effect. From the fertility rates, it can be deduced that the advent of structural adjustment has led to a resurgence of a neo-Malthusianism approach, putting family planning on the front burner, to the detriment of reproductive health.

  5. China exported birefringent filter

    Science.gov (United States)

    Li, Ting; Mao, Weijun; Lu, Haitian; Zhu, Yong

    2001-09-01

    Since 1960s, Nanjing Astronomical Instrument Research center of CAS have been developing the birefringent filters for China solar observatories, the most famous one in the world is the 0.15Å(0.12Å)/5324Å(4861Å) filter for the 35cm Solar Magnetic Field Telescope of the Huairou Solar Station of Beijing Observatory. The big success in the field of Lyot filter has been proved by the international solar physics circle, since 1988, Japanese and Korean astronomers have been paying a lot of orders for making Lyot filters from China, up to now we have exported 11 sets of such sophisticated optical instruments, they have been used for routine solar observations in the observatories and planetaria in the two countries. We also begin to repair old Lyot filters made by Germany and France from foreign countries, as India and Germany.

  6. Sub-micron filter

    Science.gov (United States)

    Tepper, Frederick [Sanford, FL; Kaledin, Leonid [Port Orange, FL

    2009-10-13

    Aluminum hydroxide fibers approximately 2 nanometers in diameter and with surface areas ranging from 200 to 650 m.sup.2/g have been found to be highly electropositive. When dispersed in water they are able to attach to and retain electronegative particles. When combined into a composite filter with other fibers or particles they can filter bacteria and nano size particulates such as viruses and colloidal particles at high flux through the filter. Such filters can be used for purification and sterilization of water, biological, medical and pharmaceutical fluids, and as a collector/concentrator for detection and assay of microbes and viruses. The alumina fibers are also capable of filtering sub-micron inorganic and metallic particles to produce ultra pure water. The fibers are suitable as a substrate for growth of cells. Macromolecules such as proteins may be separated from each other based on their electronegative charges.

  7. Filter cake breaker systems

    Energy Technology Data Exchange (ETDEWEB)

    Garcia, Marcelo H.F. [Poland Quimica Ltda., Duque de Caxias, RJ (Brazil)

    2004-07-01

    Drilling fluids filter cakes are based on a combination of properly graded dispersed particles and polysaccharide polymers. High efficiency filter cakes are formed by these combination , and their formation on wellbore walls during the drilling process has, among other roles, the task of protecting the formation from instantaneous or accumulative invasion of drilling fluid filtrate, granting stability to well and production zones. Filter cake minimizes contact between drilling fluid filtrate and water, hydrocarbons and clay existent in formations. The uniform removal of the filter cake from the entire interval is a critical factor of the completion process. The main methods used to breaking filter cake are classified into two groups, external or internal, according to their removal mechanism. The aim of this work is the presentation of these mechanisms as well their efficiency. (author)

  8. A Comb Filter Design Method Using Linear Phase FIR Filter

    Science.gov (United States)

    Sugiura, Yosuke; Kawamura, Arata; Iiguni, Youji

    This paper proposes a comb filter design method which utilizes two linear phase FIR filters for flexibly adjusting the comb filter's frequency response. The first FIR filter is used to individually adjust the notch gains, which denote the local minimum gains of the comb filter's frequency response. The second FIR filter is used to design the elimination bandwidths for individual notch gains. We also derive an efficient comb filter by incorporating these two FIR filters with an all-pass filter which is used in a conventional comb filter to accurately align the nulls with the undesired harmonic frequencies. Several design examples of the derived comb filter show the effectiveness of the proposed comb filter design method.

  9. Ceramic fiber reinforced filter

    Science.gov (United States)

    Stinton, David P.; McLaughlin, Jerry C.; Lowden, Richard A.

    1991-01-01

    A filter for removing particulate matter from high temperature flowing fluids, and in particular gases, that is reinforced with ceramic fibers. The filter has a ceramic base fiber material in the form of a fabric, felt, paper of the like, with the refractory fibers thereof coated with a thin layer of a protective and bonding refractory applied by chemical vapor deposition techniques. This coating causes each fiber to be physically joined to adjoining fibers so as to prevent movement of the fibers during use and to increase the strength and toughness of the composite filter. Further, the coating can be selected to minimize any reactions between the constituents of the fluids and the fibers. A description is given of the formation of a composite filter using a felt preform of commercial silicon carbide fibers together with the coating of these fibers with pure silicon carbide. Filter efficiency approaching 100% has been demonstrated with these filters. The fiber base material is alternately made from aluminosilicate fibers, zirconia fibers and alumina fibers. Coating with Al.sub.2 O.sub.3 is also described. Advanced configurations for the composite filter are suggested.

  10. Circuits and filters handbook

    CERN Document Server

    Chen, Wai-Kai

    2003-01-01

    A bestseller in its first edition, The Circuits and Filters Handbook has been thoroughly updated to provide the most current, most comprehensive information available in both the classical and emerging fields of circuits and filters, both analog and digital. This edition contains 29 new chapters, with significant additions in the areas of computer-aided design, circuit simulation, VLSI circuits, design automation, and active and digital filters. It will undoubtedly take its place as the engineer's first choice in looking for solutions to problems encountered in the design, analysis, and behavi

  11. Experimental studies on a single-stage compressor equipped with profiles with controlled retardation. Phase 2. Final report; Experimentelle Untersuchungen an einem einstufigen Verdichter mit Profilen mit kontrollierter Verzoegerung. Phase 2. Schlussbericht

    Energy Technology Data Exchange (ETDEWEB)

    Blaha, C.; Schulze, G.

    1996-04-01

    As part of the TurboTech study detailed measurements were performed on compressor cascades, single-stage machines, and whole compressors. The purpose of this was to gain greater clarity concerning flow conditions in compressors. The experimental results obtained were to permit a refinement of the calculation methods thus creating a reliable tool for dimensioning the HTGT compressors. The project described here is dedicated to the single stage. The tasks of phase II can be divided as follows: determination of the performance map; numerical simulation of operating behaviour; dimensioning check; analysis of the simulation and measurements and their comparison; and further measurements for the study of special flow phenomena and development of an experimental - data base for the validation of calculation methods. (orig./GL) [Deutsch] Im Rahmen von TurboTech werden detaillierte Messungen an Verdichtergittern, einstufigen Maschinen und Gesamtverdichtern durchgefuehrt, um groessere Klarheit ueber die Stroemungsverhaeltnisse in Verdichtern zu erlangen. Hierbei sollen mit Hilfe der Versuchsergebnisse die Rechenverfahren verfeinert werden, um so ein zuverlaessiges Werkzeug zur Auslegung des HTGT Verdichters in die Hand zu bekommen. Das beschriebene Vorhaben ist der Einzelstufe gewidmet. Die Aufgaben der Phase II unterteilten sich in folgende Punkte: - Vermessung des Kennfeldes - Numerische Simulation des Betriebsverhaltens - Ueberpruefung der Auslegung - Analyse der Simulation und der Messungen sowie deren Vergleich - Durchfuehrung weiterer Messungen zur Untersuchung spezieller Stroemungsphaenomene und Schaffung einer Basis experimenteller Daten zur Validierung von Rechenverfahren. (orig./GL)

  12. Paul Rodgersi filter Kohilas

    Index Scriptorium Estoniae

    2000-01-01

    28. I Kohila keskkoolis kohaspetsiifiline skulptuur ja performance "Filter". Kooli 130. aastapäeva tähistava ettevõtmise eesotsas oli skulptor Paul Rodgers ja kaks viimase klassi noormeest ئ Marko Heinmäe, Hendrik Karm.

  13. Dust filter testing

    International Nuclear Information System (INIS)

    Dupoux, J.

    1975-01-01

    The composition of dust filters used in cleanup systems for radioactive gaseous effluents is described as well as the technical controls, especially efficiency measured by a soda fluorescein aerosol [fr

  14. Vena cava filter

    International Nuclear Information System (INIS)

    Helmberger, T.

    2007-01-01

    Fulminant pulmonary embolism is one of the major causes of death in the Western World. In most cases, deep leg and pelvic venous thrombosis are the cause. If an anticoagulant/thrombotic therapy is no longer possible or ineffective, a vena cava filter implant may be indicated if an embolism is threatening. Implantation of the filter is a simple and safe intervention. Nevertheless, it is necessary to take into consideration that the data base for determining the indications for this treatment are very limited. Currently, a reduction in the risk of thromboembolism with the use of filters of about 30%, of recurrences of almost 5% and fatal pulmonary embolism of 1% has been reported, with a risk of up to 20% of filter induced vena cava thrombosis. (orig.) [de

  15. Perspectives on Nonlinear Filtering

    KAUST Repository

    Law, Kody

    2015-01-07

    The solution to the problem of nonlinear filtering may be given either as an estimate of the signal (and ideally some measure of concentration), or as a full posterior distribution. Similarly, one may evaluate the fidelity of the filter either by its ability to track the signal or its proximity to the posterior filtering distribution. Hence, the field enjoys a lively symbiosis between probability and control theory, and there are plenty of applications which benefit from algorithmic advances, from signal processing, to econometrics, to large-scale ocean, atmosphere, and climate modeling. This talk will survey some recent theoretical results involving accurate signal tracking with noise-free (degenerate) dynamics in high-dimensions (infinite, in principle, but say d between 103 and 108 , depending on the size of your application and your computer), and high-fidelity approximations of the filtering distribution in low dimensions (say d between 1 and several 10s).

  16. Updating the OMERACT filter

    DEFF Research Database (Denmark)

    Tugwell, Peter; Boers, Maarten; D'Agostino, Maria-Antonietta

    2014-01-01

    OBJECTIVE: The Outcome Measures in Rheumatology (OMERACT) Filter provides guidelines for the development and validation of outcome measures for use in clinical research. The "Truth" section of the OMERACT Filter requires that criteria be met to demonstrate that the outcome instrument meets...... the criteria for content, face, and construct validity. METHODS: Discussion groups critically reviewed a variety of ways in which case studies of current OMERACT Working Groups complied with the Truth component of the Filter and what issues remained to be resolved. RESULTS: The case studies showed...... that there is broad agreement on criteria for meeting the Truth criteria through demonstration of content, face, and construct validity; however, several issues were identified that the Filter Working Group will need to address. CONCLUSION: These issues will require resolution to reach consensus on how Truth...

  17. HEPA air filter (image)

    Science.gov (United States)

    ... pet dander and other irritating allergens from the air. Along with other methods to reduce allergens, such ... controlling the amount of allergens circulating in the air. HEPA filters can be found in most air ...

  18. Switching power supply filter

    Science.gov (United States)

    Kumar, Prithvi R. (Inventor); Abare, Wayne (Inventor)

    1989-01-01

    A filter for a switching power supply. The filter includes a common mode inductor with coil configurations allowing differential mode current from a dc source to pass through but attenuating common mode noise from the power supply so that the noise does not reach the dc source. The invention also includes the use of feed through capacitors at the switching power supply input terminals to provide further high-frequency noise attenuation.

  19. Spatial filter issues

    International Nuclear Information System (INIS)

    Murray, J.E.; Estabrook, K.G.; Milam, D.; Sell, W.D.; Van Wonterghem, R.M.; Feil, M.D.; Rubenchick, A.M.

    1996-01-01

    Experiments and calculations indicate that the threshold pressure in spatial filters for distortion of a transmitted pulse scales approximately as I O.2 and (F number-sign) 2 over the intensity range from 10 14 to 2xlO 15 W/CM 2 . We also demonstrated an interferometric diagnostic that will be used to measure the scaling relationships governing pinhole closure in spatial filters

  20. Inorganic UV filters

    Directory of Open Access Journals (Sweden)

    Eloísa Berbel Manaia

    2013-06-01

    Full Text Available Nowadays, concern over skin cancer has been growing more and more, especially in tropical countries where the incidence of UVA/B radiation is higher. The correct use of sunscreen is the most efficient way to prevent the development of this disease. The ingredients of sunscreen can be organic and/or inorganic sun filters. Inorganic filters present some advantages over organic filters, such as photostability, non-irritability and broad spectrum protection. Nevertheless, inorganic filters have a whitening effect in sunscreen formulations owing to the high refractive index, decreasing their esthetic appeal. Many techniques have been developed to overcome this problem and among them, the use of nanotechnology stands out. The estimated amount of nanomaterial in use must increase from 2000 tons in 2004 to a projected 58000 tons in 2020. In this context, this article aims to analyze critically both the different features of the production of inorganic filters (synthesis routes proposed in recent years and the permeability, the safety and other characteristics of the new generation of inorganic filters.

  1. Anthelmintic effect of carob pods and sainfoin hay when fed to lambs after experimental trickle infections with Haemonchus contortus and Trichostrongylus colubriformis.

    Science.gov (United States)

    Arroyo-Lopez, Celia; Manolaraki, Foteini; Saratsis, Anastasios; Saratsi, Katerina; Stefanakis, Alexandros; Skampardonis, Vasileios; Voutzourakis, Nikolaos; Hoste, Hervé; Sotiraki, Smaragda

    2014-01-01

    The aim of the study was to compare the in vivo anthelmintic activity of sainfoin hay (Onobrychis viciifolia) and carob pod meal (Ceratonia siliqua) against gastrointestinal nematodes. Seven days before infection, 64 naive lambs were assigned to four different groups: Group S received sainfoin hay and group CAR was fed with carob pods. The remaining lambs received lucerne hay (Medicago sativa) and were assigned to positive (non-treated, NT) and negative (treated, T) control groups (treatment with albendazole). On day 0, lambs were artificially trickle infected for 6 weeks, with a mixture of infective larvae of Haemonchus contortus and Trichostrongylus colubriformis. Parasitological and pathophysiological parameters were measured repeatedly during the 2-month study. Compared to the NT group, decreases in egg excretion were observed in the CAR and S groups with significant differences only found for sainfoin (p < 0.05). At necropsy, group S showed decreases in the total worm numbers of both nematode species with significant differences for H. contortus. In contrast, no differences were noticed for the CAR group. Compared to the NT group, lower values for fecundity of female H. contortus were found in the S and CAR groups, however differences were non-significant. No differences in body weight gains were found between groups. Consistent results were found showing significantly higher packed cell volume (PCV) values in the T and S groups compared to NT and CAR groups. Overall, these results confirm a positive effect associated with the feeding of lambs with tanniniferous resources on host resilience (PCV values) and against gastrointestinal parasitic nematodes by affecting some biological traits of worm populations (e.g. eggs per gram of faeces and worm numbers). However, the anthelmintic effects differed between the two tannin-containing resources, which might be associated with the quantity and/or quality of secondary metabolites (condensed tannins and/or other

  2. Effect of loading types on performance characteristics of a trickle-bed bioreactor and biofilter during styrene/acetone vapor biofiltration.

    Science.gov (United States)

    Halecky, Martin; Paca, Jan; Kozliak, Evguenii; Jones, Kim

    2016-07-02

    A 2:1 (w/w) mixture of styrene (STY) and acetone (AC) was subjected to lab-scale biofiltration under varied loading in both a trickle bed reactor (TBR) and biofilter (BF) to investigate substrate interactions and determine the limits of biofiltration efficiency of typical binary air pollutant mixtures containing both hydrophobic and polar components. A comparison of the STY/AC mixture degradation in the TBR and BF revealed higher pollutant removal efficiencies and degradation rates in the TBR, with the pollutant concentrations increasing up to the overloading limit. The maximum styrene degradation rates were 12 and 8 gc m(-3) h(-1) for the TBR and BF, respectively. However, the order of performance switched in favor of the BF when the loading was conducted by increasing air flow rate while keeping the inlet styrene concentration (Cin) constant in contrast to loading by increasing Cin. This switch may be due to a drastic difference in the effective surface area between these two reactors, so the biofilter becomes the reactor of choice when the rate-limiting step switches from biochemical processes to mass transfer by changing the loading mode. The presence of acetone in the mixture decreased the efficiency of styrene degradation and its degradation rate at high loadings. When the overloading was lifted by lowering the pollutant inlet concentrations, short-term back-stripping of both substrates in both reactors into the outlet air was observed, with a subsequent gradual recovery taking several hours and days in the BF and TBR, respectively. Removal of excess biomass from the TBR significantly improved the reactor performance. Identification of the cultivable strains, which was performed on Day 763 of continuous operation, showed the presence of 7 G(-) bacteria, 2 G(+) bacteria and 4 fungi. Flies and larvae of Lycoriella nigripes survived half a year of the biofilter operation by feeding on the biofilm resulting in the maintenance of a nearly constant pressure drop.

  3. Associations between blood gastrin, ghrelin, leptin, pepsinogen and Ostertagia ostertagi antibody concentrations and voluntary feed intake in calves exposed to a trickle infection with O. ostertagi.

    Science.gov (United States)

    Forbes, A B; Warren, M; Upjohn, M; Jackson, B; Jones, J; Charlier, J; Fox, M T

    2009-06-10

    Twenty-five, castrated male Holstein-cross calves, between 4 and 5 months of age, weighing 156.5+/-12.2 kg and reared under conditions designed to minimise the risk of parasitic infection, were allocated to one of the five treatment groups on the basis of initial bodyweight. The groups were (1) ad libitum (ad lib) fed controls (ALC); (2) ad lib fed infected (INF) and treated with topical eprinomectin on Day 56; (3) controls pair-fed with the INF group (PFC); (4) ad lib fed controls treated with eprinomectin on Days 0 and 56 (E-ALC) and (5) ad lib fed, infected and treated with eprinomectin on Days 0 and 56 (E-INF). Infection comprised a trickle infection with the equivalent of 10,000 larvae of Ostertagia ostertagi per day from Day 0 to Day 56 and the study concluded on Day 77. Parameters measured throughout the study included: liveweight, feed intake, faecal egg counts; plasma pepsinogen, gastrin, ghrelin and leptin; plasma antibodies to adult O. ostertagi. No significant differences in feed intake or liveweight gain were observed between any of the different groups, a finding thought to result from the high quality of feed offered. Significant differences between the INF and control groups however were observed in faecal egg counts, plasma pepsinogen, gastrin and O. ostertagi antibodies, which were all elevated, and leptin, which was reduced. Values of these parameters for the E-INF group were intermediate between the INF and ALC groups. Plasma ghrelin showed no association with either feed intake or parasitism. Further studies are needed to fully elucidate the roles of various biochemical and neuroendocrine mediators for inappetence in ruminants with parasitic gastroenteritis.

  4. Anthelmintic effect of carob pods and sainfoin hay when fed to lambs after experimental trickle infections with Haemonchus contortus and Trichostrongylus colubriformis

    Directory of Open Access Journals (Sweden)

    Arroyo-Lopez Celia

    2014-01-01

    Full Text Available The aim of the study was to compare the in vivo anthelmintic activity of sainfoin hay (Onobrychis viciifolia and carob pod meal (Ceratonia siliqua against gastrointestinal nematodes. Seven days before infection, 64 naive lambs were assigned to four different groups: Group S received sainfoin hay and group CAR was fed with carob pods. The remaining lambs received lucerne hay (Medicago sativa and were assigned to positive (non-treated, NT and negative (treated, T control groups (treatment with albendazole. On day 0, lambs were artificially trickle infected for 6 weeks, with a mixture of infective larvae of Haemonchus contortus and Trichostrongylus colubriformis. Parasitological and pathophysiological parameters were measured repeatedly during the 2-month study. Compared to the NT group, decreases in egg excretion were observed in the CAR and S groups with significant differences only found for sainfoin (p < 0.05. At necropsy, group S showed decreases in the total worm numbers of both nematode species with significant differences for H. contortus. In contrast, no differences were noticed for the CAR group. Compared to the NT group, lower values for fecundity of female H. contortus were found in the S and CAR groups, however differences were non-significant. No differences in body weight gains were found between groups. Consistent results were found showing significantly higher packed cell volume (PCV values in the T and S groups compared to NT and CAR groups. Overall, these results confirm a positive effect associated with the feeding of lambs with tanniniferous resources on host resilience (PCV values and against gastrointestinal parasitic nematodes by affecting some biological traits of worm populations (e.g. eggs per gram of faeces and worm numbers. However, the anthelmintic effects differed between the two tannin-containing resources, which might be associated with the quantity and/or quality of secondary metabolites (condensed tannins and

  5. Sensory Pollution from Bag Filters, Carbon Filters and Combinations

    DEFF Research Database (Denmark)

    Bekö, Gabriel; Clausen, Geo; Weschler, Charles J.

    2008-01-01

    Used ventilation filters are a major source of sensory pollutants in air handling systems. The objective of the present study was to evaluate the net effect that different combinations of filters had on perceived air quality after 5 months of continuous filtration of outdoor suburban air. A panel...... that contained AC and a synthetic fiber cartridge filter that contained AC. Air that had passed through used filters was most acceptable for those sets in which an AC filter was used downstream of the particle filter. Comparable air quality was achieved with the stand-alone bag filter that contained AC...

  6. Multistage second-order microring-resonator filters with box-like spectral responses and relaxed fabrication tolerances

    Science.gov (United States)

    Zhao, Haiyang; Zhang, Lei; Shao, Sizhu; Ding, Jianfeng; Fu, Xin; Yang, Lin

    2017-11-01

    We demonstrate an optical filter based on multistage second-order microring resonators (MRs) with box-like spectral responses. Compared with single-stage high-order optical filters with the same number of MRs, the demonstrated structure has comparable performances in the aspects of passband flatness, rolling-off slope and insertion loss. Moreover, the architecture relaxes the fabrication tolerance, electrical wiring and tuning difficulty since there are only two MRs in each stage. We experimentally demonstrate this kind of optical filter with five stages, which shows a 3-dB bandwidth of ~17 GHz, a rolling-off slope of ~5 dB/GHz and an on-chip insertion loss of ~6 dB. Project supported by the National High Technology Research and Development Program of China (Nos. 2015AA017001, 2015AA010103) and the Natural National Science Foundation of China (NSFC) (Nos. 61235001, 61575187, 61535002, 61204061, 6157031748, 61377067).

  7. Multi-stage versus single-stage inflation and deflation cycle for alternating low pressure air mattresses to prevent pressure ulcers in hospitalised patients: a randomised-controlled clinical trial.

    Science.gov (United States)

    Demarré, L; Beeckman, D; Vanderwee, K; Defloor, T; Grypdonck, M; Verhaeghe, S

    2012-04-01

    The duration and the amount of pressure and shear must be reduced in order to minimize the risk of pressure ulcer development. Alternating low pressure air mattresses with multi-stage inflation and deflation cycle of the air cells have been developed to relieve pressure by sequentially inflating and deflating the air cells. Evidence about the effectiveness of this type of mattress in clinical practice is lacking. This study aimed to compare the effectiveness of an alternating low pressure air mattress that has a standard single-stage inflation and deflation cycle of the air cells with an alternating low pressure air mattress with multi-stage inflation and deflation cycle of the air cells. A randomised controlled trial was performed in a convenience sample of 25 wards in five hospitals in Belgium. In total, 610 patients were included and randomly assigned to the experimental group (n=298) or the control group (n=312). In the experimental group, patients were allocated to an alternating low pressure air mattress with multi-stage inflation and deflation cycle of the air cells. In the control group, patients were allocated to an alternating low pressure air mattress with a standard single-stage inflation and deflation cycle of the air cells. The outcome was defined as cumulative pressure ulcer incidence (Grade II-IV). An intention-to-treat analysis was performed. There was no significant difference in cumulative pressure ulcer incidence (Grade II-IV) between both groups (Exp.=5.7%, Contr.=5.8%, p=0.97). When patients developed a pressure ulcer, the median time was 5.0 days in the experimental group (IQR=3.0-8.5) and 8.0 days in the control group (IQR=3.0-8.5) (Mann-Whitney U-test=113, p=0.182). The probability to remain pressure ulcer free during the observation period in this trial did not differ significantly between the experimental group and the control group (log-rank χ(2)=0.013, df=1, p=0.911). An alternating low pressure air mattress with multi-stage inflation

  8. Choosing and using astronomical filters

    CERN Document Server

    Griffiths, Martin

    2014-01-01

    As a casual read through any of the major amateur astronomical magazines will demonstrate, there are filters available for all aspects of optical astronomy. This book provides a ready resource on the use of the following filters, among others, for observational astronomy or for imaging: Light pollution filters Planetary filters Solar filters Neutral density filters for Moon observation Deep-sky filters, for such objects as galaxies, nebulae and more Deep-sky objects can be imaged in much greater detail than was possible many years ago. Amateur astronomers can take

  9. Multilevel ensemble Kalman filtering

    KAUST Repository

    Hoel, Haakon

    2016-01-08

    The ensemble Kalman filter (EnKF) is a sequential filtering method that uses an ensemble of particle paths to estimate the means and covariances required by the Kalman filter by the use of sample moments, i.e., the Monte Carlo method. EnKF is often both robust and efficient, but its performance may suffer in settings where the computational cost of accurate simulations of particles is high. The multilevel Monte Carlo method (MLMC) is an extension of classical Monte Carlo methods which by sampling stochastic realizations on a hierarchy of resolutions may reduce the computational cost of moment approximations by orders of magnitude. In this work we have combined the ideas of MLMC and EnKF to construct the multilevel ensemble Kalman filter (MLEnKF) for the setting of finite dimensional state and observation spaces. The main ideas of this method is to compute particle paths on a hierarchy of resolutions and to apply multilevel estimators on the ensemble hierarchy of particles to compute Kalman filter means and covariances. Theoretical results and a numerical study of the performance gains of MLEnKF over EnKF will be presented. Some ideas on the extension of MLEnKF to settings with infinite dimensional state spaces will also be presented.

  10. Adaptive digital filters

    CERN Document Server

    Kovačević, Branko; Milosavljević, Milan

    2013-01-01

    “Adaptive Digital Filters” presents an important discipline applied to the domain of speech processing. The book first makes the reader acquainted with the basic terms of filtering and adaptive filtering, before introducing the field of advanced modern algorithms, some of which are contributed by the authors themselves. Working in the field of adaptive signal processing requires the use of complex mathematical tools. The book offers a detailed presentation of the mathematical models that is clear and consistent, an approach that allows everyone with a college level of mathematics knowledge to successfully follow the mathematical derivations and descriptions of algorithms.   The algorithms are presented in flow charts, which facilitates their practical implementation. The book presents many experimental results and treats the aspects of practical application of adaptive filtering in real systems, making it a valuable resource for both undergraduate and graduate students, and for all others interested in m...

  11. Stack filter classifiers

    Energy Technology Data Exchange (ETDEWEB)

    Porter, Reid B [Los Alamos National Laboratory; Hush, Don [Los Alamos National Laboratory

    2009-01-01

    Just as linear models generalize the sample mean and weighted average, weighted order statistic models generalize the sample median and weighted median. This analogy can be continued informally to generalized additive modeels in the case of the mean, and Stack Filters in the case of the median. Both of these model classes have been extensively studied for signal and image processing but it is surprising to find that for pattern classification, their treatment has been significantly one sided. Generalized additive models are now a major tool in pattern classification and many different learning algorithms have been developed to fit model parameters to finite data. However Stack Filters remain largely confined to signal and image processing and learning algorithms for classification are yet to be seen. This paper is a step towards Stack Filter Classifiers and it shows that the approach is interesting from both a theoretical and a practical perspective.

  12. Automated electronic filter design

    CERN Document Server

    Banerjee, Amal

    2017-01-01

    This book describes a novel, efficient and powerful scheme for designing and evaluating the performance characteristics of any electronic filter designed with predefined specifications. The author explains techniques that enable readers to eliminate complicated manual, and thus error-prone and time-consuming, steps of traditional design techniques. The presentation includes demonstration of efficient automation, using an ANSI C language program, which accepts any filter design specification (e.g. Chebyschev low-pass filter, cut-off frequency, pass-band ripple etc.) as input and generates as output a SPICE(Simulation Program with Integrated Circuit Emphasis) format netlist. Readers then can use this netlist to run simulations with any version of the popular SPICE simulator, increasing accuracy of the final results, without violating any of the key principles of the traditional design scheme.

  13. Filters in topology optimization

    DEFF Research Database (Denmark)

    Bourdin, Blaise

    1999-01-01

    In this article, a modified (``filtered'') version of the minimum compliance topology optimization problem is studied. The direct dependence of the material properties on its pointwise density is replaced by a regularization of the density field using a convolution operator. In this setting...... it is possible to establish the existence of solutions. Moreover, convergence of an approximation by means of finite elements can be obtained. This is illustrated through some numerical experiments. The ``filtering'' technique is also shown to cope with two important numerical problems in topology optimization...

  14. Alarm filtering and presentation

    International Nuclear Information System (INIS)

    Bray, M.A.

    1989-01-01

    This paper discusses alarm filtering and presentation in the control room of nuclear and other process control plants. Alarm generation and presentation is widely recognized as a general process control problem. Alarm systems often fail to provide meaningful alarms to operators. Alarm generation and presentation is an area in which computer aiding is feasible and provides clear benefits. Therefore, researchers have developed several computerized alarm filtering and presentation approaches. This paper discusses problems associated with alarm generation and presentation. Approaches to improving the alarm situation and installation issues of alarm system improvements are discussed. The impact of artificial intelligence (AI) technology on alarm system improvements is assessed. (orig.)

  15. Statistically-Efficient Filtering in Impulsive Environments: Weighted Myriad Filters

    Directory of Open Access Journals (Sweden)

    Gonzalez Juan G

    2002-01-01

    Full Text Available Linear filtering theory has been largely motivated by the characteristics of Gaussian signals. In the same manner, the proposed Myriad Filtering methods are motivated by the need for a flexible filter class with high statistical efficiency in non-Gaussian impulsive environments that can appear in practice. Myriad filters have a solid theoretical basis, are inherently more powerful than median filters, and are very general, subsuming traditional linear FIR filters. The foundation of the proposed filtering algorithms lies in the definition of the myriad as a tunable estimator of location derived from the theory of robust statistics. We prove several fundamental properties of this estimator and show its optimality in practical impulsive models such as the -stable and generalized- . We then extend the myriad estimation framework to allow the use of weights. In the same way as linear FIR filters become a powerful generalization of the mean filter, filters based on running myriads reach all of their potential when a weighting scheme is utilized. We derive the "normal" equations for the optimal myriad filter, and introduce a suboptimal methodology for filter tuning and design. The strong potential of myriad filtering and estimation in impulsive environments is illustrated with several examples.

  16. The ATLAS event filter

    CERN Document Server

    Beck, H P; Boissat, C; Davis, R; Duval, P Y; Etienne, F; Fede, E; Francis, D; Green, P; Hemmer, F; Jones, R; MacKinnon, J; Mapelli, Livio P; Meessen, C; Mommsen, R K; Mornacchi, Giuseppe; Nacasch, R; Negri, A; Pinfold, James L; Polesello, G; Qian, Z; Rafflin, C; Scannicchio, D A; Stanescu, C; Touchard, F; Vercesi, V

    1999-01-01

    An overview of the studies for the ATLAS Event Filter is given. The architecture and the high level design of the DAQ-1 prototype is presented. The current status if the prototypes is briefly given. Finally, future plans and milestones are given. (11 refs).

  17. Spectral Ensemble Kalman Filters

    Czech Academy of Sciences Publication Activity Database

    Mandel, Jan; Kasanický, Ivan; Vejmelka, Martin; Fuglík, Viktor; Turčičová, Marie; Eben, Kryštof; Resler, Jaroslav; Juruš, Pavel

    2014-01-01

    Roč. 11, - (2014), EMS2014-446 [EMS Annual Meeting /14./ & European Conference on Applied Climatology (ECAC) /10./. 06.10.2014-10.10.2014, Prague] R&D Projects: GA ČR GA13-34856S Grant - others:NSF DMS -1216481 Institutional support: RVO:67985807 Keywords : data assimilation * spectral filter Subject RIV: DG - Athmosphere Sciences, Meteorology

  18. Filter and Passband Problems

    Science.gov (United States)

    Young, A. T.

    1984-01-01

    Problems associated with achieving precision in photometric measurements of stars are examined. The thermal stabilization of glass and interference filters and the determination of correct analytic representations of bandwidth effects in data reduction are particularly discussed. Spectral sampling requirements are also addressed.

  19. Ceramic HEPA Filter Program

    Energy Technology Data Exchange (ETDEWEB)

    Mitchell, M A; Bergman, W; Haslam, J; Brown, E P; Sawyer, S; Beaulieu, R; Althouse, P; Meike, A

    2012-04-30

    Potential benefits of ceramic filters in nuclear facilities: (1) Short term benefit for DOE, NRC, and industry - (a) CalPoly HTTU provides unique testing capability to answer questions for DOE - High temperature testing of materials, components, filter, (b) Several DNFSB correspondences and presentations by DNFSB members have highlighted the need for HEPA filter R and D - DNFSB Recommendation 2009-2 highlighted a nuclear facility response to an evaluation basis earthquake followed by a fire (aka shake-n-bake) and CalPoly has capability for a shake-n-bake test; (2) Intermediate term benefit for DOE and industry - (a) Filtration for specialty applications, e.g., explosive applications at Nevada, (b) Spin-off technologies applicable to other commercial industries; and (3) Long term benefit for DOE, NRC, and industry - (a) Across industry, strong desire for better performance filter, (b) Engineering solution to safety problem will improve facility safety and decrease dependence on associated support systems, (c) Large potential life-cycle cost savings, and (d) Facilitates development and deployment of LLNL process innovations to allow continuous ventilation system operation during a fire.

  20. Avaliação de sistemas de irrigação por gotejamento, utilizados na cafeicultura Evaluation of trickle irrigation systems used in coffee crop

    Directory of Open Access Journals (Sweden)

    Luís O. C. de Souza

    2006-09-01

    Full Text Available Este trabalho foi conduzido no período de agosto a outubro de 1999, com o objetivo de avaliar os sistemas de irrigação por gotejamento utilizados na cafeicultura irrigada do norte do Espírito Santo e nas áreas de cerrado de Minas Gerais e caracterizar a porcentagem de área molhada (PAM nesses sistemas de irrigação. Foram realizadas medidas das dimensões do bulbo molhado para determinação da porcentagem de área molhada. Pelos resultados obtidos verificou-se que, dos valores de coeficiente de uniformidade de distribuição determinados, apenas um sistema apresentou valor abaixo de 70%, refletindo uma uniformidade ruim. No que se refere aos demais resultados, dez sistemas indicaram valores de uniformidade de distribuição entre 70 e 80%, oito sistemas mostraram valores entre 80 e 90% e doze sistemas apontaram valores acima de 90%, indicando uniformidade razoável, boa e excelente, respectivamente. Dos valores determinados, a maioria dos sistemas que apresentaram uniformidade de boa a excelente estava situada na região de cerrado de Minas Gerais. Com relação à PAM, os valores determinados variaram na faixa de 19 a 100% e apenas um sistema apresentou valor abaixo do limite mínimo recomendado para regiões úmidas, que é de 20%.This study was carried out over the period from August to October 1999, aiming the evaluation of trickle irrigation systems used in coffee crop in the northern part of Espírito Santo State and the savannah areas of Minas Gerais State, as well as to characterize the percentage of wetted area (PWA of these irrigation systems. The wetted bulb dimensions measurements were accomplished for determining the percent wetted area. According to the results, just one system presented a value lower than 70% for the distribution uniformity coefficient, reflecting a bad uniformity. Concerning to the other results, ten systems showed the distribution uniformity values ranging from 70 to 80%, whereas for eight systems, it

  1. Digital Simulation of a Hybrid Active Filter - An Active Filter in Series with a Shunt Passive Filter

    OpenAIRE

    Sitaram, Mahesh I; Padiyar, KR; Ramanarayanan, V

    1998-01-01

    Active filters have long been in use for the filtering of power system load harmonics. In this paper, the digital simulation results of a hybrid active power filter system for a rectifier load are presented. The active filter is used for filtering higher order harmonics as the dominant harmonics are filtered by the passive filter. This reduces the rating of the active filter significantly. The DC capacitor voltage of the active filter is controlled using a PI controller.

  2. Numerical study of canister filters with alternatives filter cap configurations

    Science.gov (United States)

    Mohammed, A. N.; Daud, A. R.; Abdullah, K.; Seri, S. M.; Razali, M. A.; Hushim, M. F.; Khalid, A.

    2017-09-01

    Air filtration system and filter play an important role in getting a good quality air into turbo machinery such as gas turbine. The filtration system and filter has improved the quality of air and protect the gas turbine part from contaminants which could bring damage. During separation of contaminants from the air, pressure drop cannot be avoided but it can be minimized thus helps to reduce the intake losses of the engine [1]. This study is focused on the configuration of the filter in order to obtain the minimal pressure drop along the filter. The configuration used is the basic filter geometry provided by Salutary Avenue Manufacturing Sdn Bhd. and two modified canister filter cap which is designed based on the basic filter model. The geometries of the filter are generated by using SOLIDWORKS software and Computational Fluid Dynamics (CFD) software is used to analyse and simulates the flow through the filter. In this study, the parameters of the inlet velocity are 0.032 m/s, 0.063 m/s, 0.094 m/s and 0.126 m/s. The total pressure drop produce by basic, modified filter 1 and 2 is 292.3 Pa, 251.11 Pa and 274.7 Pa. The pressure drop reduction for the modified filter 1 is 41.19 Pa and 14.1% lower compared to basic filter and the pressure drop reduction for modified filter 2 is 17.6 Pa and 6.02% lower compared to the basic filter. The pressure drops for the basic filter are slightly different with the Salutary Avenue filter due to limited data and experiment details. CFD software are very reliable in running a simulation rather than produces the prototypes and conduct the experiment thus reducing overall time and cost in this study.

  3. Digital Filters for Low Frequency Equalization

    DEFF Research Database (Denmark)

    Tyril, Marni; Abildgaard, J.; Rubak, Per

    2001-01-01

    Digital filters with high resolution in the low-frequency range are studied. Specifically, for a given computational power, traditional IIR filters are compared with warped FIR filters, warped IIR filters, and modified warped FIR filters termed warped individual z FIR filters (WizFIR). The results...... indicate that IIR filters are the most effective in a number of situations....

  4. Hydrodynamics of microbial filter feeding

    DEFF Research Database (Denmark)

    Nielsen, Lasse Tor; Asadzadeh, Seyed Saeed; Dölger, Julia

    2017-01-01

    Microbial filter feeders are an important group of grazers, significant to the microbial loop, aquatic food webs, and biogeochemical cycling. Our understanding of microbial filter feeding is poor, and, importantly, it is unknown what force microbial filter feeders must generate to process adequate...... amounts of water. Also, the trade-off in the filter spacing remains unexplored, despite its simple formulation: A filter too coarse will allow suitably sized prey to pass unintercepted, whereas a filter too fine will cause strong flow resistance. We quantify the feeding flow of the filter......-feeding choanoflagellate Diaphanoeca grandis using particle tracking, and demonstrate that the current understanding of microbial filter feeding is inconsistent with computational fluid dynamics (CFD) and analytical estimates. Both approaches underestimate observed filtration rates by more than an order of magnitude...

  5. Analog filters in nanometer CMOS

    CERN Document Server

    Uhrmann, Heimo; Zimmermann, Horst

    2014-01-01

    Starting from the basics of analog filters and the poor transistor characteristics in nanometer CMOS 10 high-performance analog filters developed by the authors in 120 nm and 65 nm CMOS are described extensively. Among them are gm-C filters, current-mode filters, and active filters for system-on-chip realization for Bluetooth, WCDMA, UWB, DVB-H, and LTE applications. For the active filters several operational amplifier designs are described. The book, furthermore, contains a review of the newest state of research on low-voltage low-power analog filters. To cover the topic of the book comprehensively, linearization issues and measurement methods for the characterization of advanced analog filters are introduced in addition. Numerous elaborate illustrations promote an easy comprehension. This book will be of value to engineers and researchers in industry as well as scientists and Ph.D students at universities. The book is also recommendable to graduate students specializing on nanoelectronics, microelectronics ...

  6. The Rao-Blackwellized Particle Filter: A Filter Bank Implementation

    Directory of Open Access Journals (Sweden)

    Karlsson Rickard

    2010-01-01

    Full Text Available For computational efficiency, it is important to utilize model structure in particle filtering. One of the most important cases occurs when there exists a linear Gaussian substructure, which can be efficiently handled by Kalman filters. This is the standard formulation of the Rao-Blackwellized particle filter (RBPF. This contribution suggests an alternative formulation of this well-known result that facilitates reuse of standard filtering components and which is also suitable for object-oriented programming. Our RBPF formulation can be seen as a Kalman filter bank with stochastic branching and pruning.

  7. On fractional filtering versus conventional filtering in economics

    Science.gov (United States)

    Nigmatullin, Raoul R.; Omay, Tolga; Baleanu, Dumitru

    2010-04-01

    In this study, we compare the Hodrick-Prescott Filter technique with the Fractional filtering technique that has recently started to be used in various applied sciences like physics, engineering, and biology. We apply these filtering techniques to quarterly GDP data from Turkey for the period 1988:1-2003:2. The filtered series are analyzed using Minimum Square Error (MSE) and real life evidence. In the second part of the study, we use simulated data to analyze the statistical properties of the aforementioned filtering techniques.

  8. Multilevel particle filter

    KAUST Repository

    Law, Kody

    2016-01-06

    This talk will pertain to the filtering of partially observed diffusions, with discrete-time observations. It is assumed that only biased approximations of the diffusion can be obtained, for choice of an accuracy parameter indexed by l. A multilevel estimator is proposed, consisting of a telescopic sum of increment estimators associated to the successive levels. The work associated to O( 2) mean-square error between the multilevel estimator and average with respect to the filtering distribution is shown to scale optimally, for example as O( 2) for optimal rates of convergence of the underlying diffusion approximation. The method is illustrated on some toy examples as well as estimation of interest rate based on real S&P 500 stock price data.

  9. Hydrodynamics of microbial filter feeding

    DEFF Research Database (Denmark)

    Nielsen, Lasse Tor; Asadzadeh, Seyed Saeed; Dölger, Julia

    2017-01-01

    Microbial filter feeders are an important group of grazers, significant to the microbial loop, aquatic food webs, and biogeochemical cycling. Our understanding of microbial filter feeding is poor, and, importantly, it is unknown what force microbial filter feeders must generate to process adequate...

  10. Matched-Filter Thermography

    Directory of Open Access Journals (Sweden)

    Nima Tabatabaei

    2018-04-01

    Full Text Available Conventional infrared thermography techniques, including pulsed and lock-in thermography, have shown great potential for non-destructive evaluation of broad spectrum of materials, spanning from metals to polymers to biological tissues. However, performance of these techniques is often limited due to the diffuse nature of thermal wave fields, resulting in an inherent compromise between inspection depth and depth resolution. Recently, matched-filter thermography has been introduced as a means for overcoming this classic limitation to enable depth-resolved subsurface thermal imaging and improving axial/depth resolution. This paper reviews the basic principles and experimental results of matched-filter thermography: first, mathematical and signal processing concepts related to matched-fileting and pulse compression are discussed. Next, theoretical modeling of thermal-wave responses to matched-filter thermography using two categories of pulse compression techniques (linear frequency modulation and binary phase coding are reviewed. Key experimental results from literature demonstrating the maintenance of axial resolution while inspecting deep into opaque and turbid media are also presented and discussed. Finally, the concept of thermal coherence tomography for deconvolution of thermal responses of axially superposed sources and creation of depth-selective images in a diffusion-wave field is reviewed.

  11. Controlling flow conditions of test filters in iodine filters

    International Nuclear Information System (INIS)

    Holmberg, R.; Laine, J.

    1979-03-01

    Several different iodine filter and test filter designs and experience gained from their operation are presented. For the flow experiments, an iodine filter system equipped with flow regulating and measuring devices was built. In the experiments the influence of the packing method of the iodine sorption material and the influence of the flow regulating and measuring divices upon the flow conditions in the test filters was studied. On the basis of the experiments it has been shown that the flows through the test filters always can be adjusted to a correct value if there only is a high enough pressure difference available across the test filter ducting. As a result of the research, several different methods are presented with which the flows through the test filters in both operating and future iodine sorption system can easily be measured and adjusted to their correct values. (author)

  12. Sharpening minimum-phase filters

    Science.gov (United States)

    Jovanovic Dolecek, G.; Fernandez-Vazquez, A.

    2013-02-01

    The minimum-phase requirement restricts that filter has all its zeros on or inside the unit circle. As a result the filter does not have a linear phase. It is well known that the sharpening technique can be used to simultaneous improvements of both the pass-band and stop-band of a linear-phase FIR filters and cannot be used for other types of filters. In this paper we demonstrate that the sharpening technique can also be applied to minimum-phase filters, after small modification. The method is illustrated with one practical examples of design.

  13. A Short Note on t-filters, I-filters and Extended Filters on Residuated Lattices

    Czech Academy of Sciences Publication Activity Database

    Víta, Martin

    2015-01-01

    Roč. 271, 15 July (2015), s. 168-171 ISSN 0165-0114 R&D Projects: GA ČR GAP202/10/1826 Institutional support: RVO:67985807 Keywords : t-filters * I-filters * extended filters * residuated lattices Subject RIV: BA - General Mathematics Impact factor: 2.098, year: 2015

  14. Multilevel ensemble Kalman filtering

    KAUST Repository

    Hoel, Hakon

    2016-06-14

    This work embeds a multilevel Monte Carlo sampling strategy into the Monte Carlo step of the ensemble Kalman filter (EnKF) in the setting of finite dimensional signal evolution and noisy discrete-time observations. The signal dynamics is assumed to be governed by a stochastic differential equation (SDE), and a hierarchy of time grids is introduced for multilevel numerical integration of that SDE. The resulting multilevel EnKF is proved to asymptotically outperform EnKF in terms of computational cost versus approximation accuracy. The theoretical results are illustrated numerically.

  15. Advances in Collaborative Filtering

    Science.gov (United States)

    Koren, Yehuda; Bell, Robert

    The collaborative filtering (CF) approach to recommenders has recently enjoyed much interest and progress. The fact that it played a central role within the recently completed Netflix competition has contributed to its popularity. This chapter surveys the recent progress in the field. Matrix factorization techniques, which became a first choice for implementing CF, are described together with recent innovations. We also describe several extensions that bring competitive accuracy into neighborhood methods, which used to dominate the field. The chapter demonstrates how to utilize temporal models and implicit feedback to extend models accuracy. In passing, we include detailed descriptions of some the central methods developed for tackling the challenge of the Netflix Prize competition.

  16. Filter and Filter Bank Design for Image Texture Recognition

    Energy Technology Data Exchange (ETDEWEB)

    Randen, Trygve

    1997-12-31

    The relevance of this thesis to energy and environment lies in its application to remote sensing such as for instance sea floor mapping and seismic pattern recognition. The focus is on the design of two-dimensional filters for feature extraction, segmentation, and classification of digital images with textural content. The features are extracted by filtering with a linear filter and estimating the local energy in the filter response. The thesis gives a review covering broadly most previous approaches to texture feature extraction and continues with proposals of some new techniques. 143 refs., 59 figs., 7 tabs.

  17. Leukodepletion blood filters: filter design and mechanisms of leukocyte removal.

    Science.gov (United States)

    Dzik, S

    1993-04-01

    Modern leukocyte removal filters have been developed after years of refinement in design. Current filters are composite filters in which synthetic microfiber material is prepared as a nonwoven web. The filter material may be surface modified to alter surface tension or charge to improve performance. The housing design promotes effective contact of blood with the filter material and decreases shear forces. The exact mechanisms by which these filters remove leukocytes from blood components are uncertain, but likely represent a combination of both physical and biological processes whose contributions to leukocyte removal are interdependent. Small-pore microfiber webs result in barrier phenomena that permit retention of individual cells and increase the total adsorptive area of the filter. Modifications in surface charge can increase or decrease cell attraction to the fibers. Optimum interfacial surface tensions between blood cells, plasma, and filter fibers not only permit effective blood flow through small fiber pores, but also facilitate cell contact with the material. Barrier retention is a common mechanism for all modern leukocyte-removal filters and applies to all leukocyte subtypes. Because barrier retention does not depend on cell viability, it is operative for cells of any age and will retain any nondeformable cell, including whole nuclei from lymphocytes or monocytes. Barrier retention is supplemented by retention by adhesion. RBCs, lymphocytes, monocytes, granulocytes, and platelets differ in their relative adhesiveness to filter fibers. Different adhesive mechanisms are used in filters designed for RBCs compared with filters designed for platelets. Although lymphocytes, monocytes, and granulocytes can adhere directly to filter fibers, the biological mechanisms underlying cell adhesion may differ for these cell types. These differences may depend on expression of cell adhesion molecules. In the case of filtration of fresh RBCs, platelet-leukocyte interaction

  18. Intelligibility of bandpass filtered speech: The effect of filter types.

    Science.gov (United States)

    Amir, Noam; Kishon-Rabin, Liat

    2017-12-01

    Many studies have examined the contribution of different spectral bands to speech intelligibility, measuring recognition scores of filtered speech stimuli. For a given filter bandwidth, the influence of filter properties on such experiments has been studied mainly with respect to transition band slopes. The objective of the present study was to determine whether nominal transition band slope is a sufficient characterization of filter properties. Several types of filters, both finite impulse response and infinite impulse response types were examined in three experiments to determine if details of the transition band behavior, as well as group delay properties, had any influence on recognition scores. The results of a total of 72 participants showed that for 1/3 octave passbands, differences between filters having the same nominal transition band slopes, but of different types, were large and statistically significant. Linearity of phase response, however, did not influence the results. Further experiments using passband widths of 1/2 and 2/3 octaves revealed that only for the latter the difference in recognition scores between filter types ceased to be significant. These results have important implications for studies which involve filtered speech as well as models that employ different types of filters to emulate peripheral auditory processing.

  19. Tandem HEPA filter tests.

    Science.gov (United States)

    Schuster, B G; Osetek, D J

    1978-02-01

    Current methods for evaluating the performance and reliability of high-efficiency air cleaning systems use forward light-scattering photometers and DOP aerosol. This method is limited to measuring protection factors of 10(4) or 10(5) and has poor sensitivity to particles less than .3 micron. More accurate determination of system performance could be made by measuring two filter stages with a single test. Because of the large protection factors of a two-stage system, it is necessary to use high challenge aerosol concentrations and long downstream sampling times. Concentrations were measured using an intra-cavity laser light-scattering aerosol spectrometer which is capable of detection of single particles ranging in size from 0.07 to 3.00 micron diameter. The results of several tests with challenge aerosols of both NaCl and DOP yielded protection factors ranging from 1.4 x 10(7) to 3.0 x 10(9) for two HEPA filters in series.

  20. Nanoparticle optical notch filters

    Science.gov (United States)

    Kasinadhuni, Pradeep Kumar

    Developing novel light blocking products involves the design of a nanoparticle optical notch filter, working on the principle of localized surface plasmon resonance (LSPR). These light blocking products can be used in many applications. One such application is to naturally reduce migraine headaches and light sensitivity. Melanopsin ganglion cells present in the retina of the human eye, connect to the suprachiasmatic nucleus (SCN-the body's clock) in the brain, where they participate in the entrainment of the circadian rhythms. As the Melanopsin ganglion cells are involved in triggering the migraine headaches in photophobic patients, it is necessary to block the part of visible spectrum that activates these cells. It is observed from the action potential spectrum of the ganglion cells that they absorb light ranging from 450-500nm (blue-green part) of the visible spectrum with a λmax (peak sensitivity) of around 480nm (blue line). Currently prescribed for migraine patients is the FL-41 coating, which blocks a broad range of wavelengths, including wavelengths associated with melanopsin absorption. The nanoparticle optical notch filter is designed to block light only at 480nm, hence offering an effective prescription for the treatment of migraine headaches.

  1. Reconfigurable Mixed Mode Universal Filter

    Directory of Open Access Journals (Sweden)

    Neelofer Afzal

    2014-01-01

    Full Text Available This paper presents a novel mixed mode universal filter configuration capable of working in voltage and transimpedance mode. The proposed single filter configuration can be reconfigured digitally to realize all the five second order filter functions (types at single output port. Other salient features of proposed configuration include independently programmable filter parameters, full cascadability, and low sensitivity figure. However, all these features are provided at the cost of quite large number of active elements. It needs three digitally programmable current feedback amplifiers and three digitally programmable current conveyors. Use of six active elements is justified by introducing three additional reduced hardware mixed mode universal filter configurations and its comparison with reported filters.

  2. DSP Control of Line Hybrid Active Filter

    DEFF Research Database (Denmark)

    Dan, Stan George; Benjamin, Doniga Daniel; Magureanu, R.

    2005-01-01

    Active Power Filters have been intensively explored in the past decade. Hybrid active filters inherit the efficiency of passive filters and the improved performance of active filters, and thus constitute a viable improved approach for harmonic compensation. In this paper a parallel hybrid filter...... is studied for current harmonic compensation. The hybrid filter is formed by a single tuned Le filter and a small-rated power active filter, which are directly connected in series without any matching transformer. Thus the required rating of the active filter is much smaller than a conventional standalone...... active filter. Simulation and experimental results obtained in laboratory confirmed the validity and effectiveness of the control....

  3. Digital filtering in nuclear medicine

    International Nuclear Information System (INIS)

    Miller, T.R.; Sampathkumaran, S.

    1982-01-01

    Digital filtering is a powerful mathematical technique in computer analysis of nuclear medicine studies. The basic concepts of object-domain and frequency-domain filtering are presented in simple, largely nonmathemaical terms. Computational methods are described using both the Fourier transform and convolution techniques. The frequency response is described and used to represent the behavior of several classes of filters. These concepts are illustrated with examples drawn from a variety of important applications in nuclear medicine

  4. Advanced simulation of digital filters

    OpenAIRE

    Doyle, Gerald S.

    1980-01-01

    Approved for public release; distribution is unlimited An Advanced Simulation of Digital Filters has been implemented on the IBM/67 computer utilizing Tektronix hardware and software. The program package is appropriate for persons beginning their study of digital signal processing or for filter analysis. The ASDF programs provide the user with an interactive method by which filter pole and zero locations can be manipulated. Graphical output on both the Tektronix graphics screen and the ...

  5. Multi-filter spectrophotometry simulations

    Science.gov (United States)

    Callaghan, Kim A. S.; Gibson, Brad K.; Hickson, Paul

    1993-01-01

    To complement both the multi-filter observations of quasar environments described in these proceedings, as well as the proposed UBC 2.7 m Liquid Mirror Telescope (LMT) redshift survey, we have initiated a program of simulated multi-filter spectrophotometry. The goal of this work, still very much in progress, is a better quantitative assessment of the multiband technique as a viable mechanism for obtaining useful redshift and morphological class information from large scale multi-filter surveys.

  6. Adaptive filtering and change detection

    CERN Document Server

    Gustafsson, Fredrik

    2003-01-01

    Adaptive filtering is a classical branch of digital signal processing (DSP). Industrial interest in adaptive filtering grows continuously with the increase in computer performance that allows ever more conplex algorithms to be run in real-time. Change detection is a type of adaptive filtering for non-stationary signals and is also the basic tool in fault detection and diagnosis. Often considered as separate subjects Adaptive Filtering and Change Detection bridges a gap in the literature with a unified treatment of these areas, emphasizing that change detection is a natural extensi

  7. The intractable cigarette 'filter problem'.

    Science.gov (United States)

    Harris, Bradford

    2011-05-01

    When lung cancer fears emerged in the 1950s, cigarette companies initiated a shift in cigarette design from unfiltered to filtered cigarettes. Both the ineffectiveness of cigarette filters and the tobacco industry's misleading marketing of the benefits of filtered cigarettes have been well documented. However, during the 1950s and 1960s, American cigarette companies spent millions of dollars to solve what the industry identified as the 'filter problem'. These extensive filter research and development efforts suggest a phase of genuine optimism among cigarette designers that cigarette filters could be engineered to mitigate the health hazards of smoking. This paper explores the early history of cigarette filter research and development in order to elucidate why and when seemingly sincere filter engineering efforts devolved into manipulations in cigarette design to sustain cigarette marketing and mitigate consumers' concerns about the health consequences of smoking. Relevant word and phrase searches were conducted in the Legacy Tobacco Documents Library online database, Google Patents, and media and medical databases including ProQuest, JSTOR, Medline and PubMed. 13 tobacco industry documents were identified that track prominent developments involved in what the industry referred to as the 'filter problem'. These reveal a period of intense focus on the 'filter problem' that persisted from the mid-1950s to the mid-1960s, featuring collaborations between cigarette producers and large American chemical and textile companies to develop effective filters. In addition, the documents reveal how cigarette filter researchers' growing scientific knowledge of smoke chemistry led to increasing recognition that filters were unlikely to offer significant health protection. One of the primary concerns of cigarette producers was to design cigarette filters that could be economically incorporated into the massive scale of cigarette production. The synthetic plastic cellulose acetate

  8. Bridging the ensemble Kalman filter and particle filters

    Energy Technology Data Exchange (ETDEWEB)

    Stordal, Andreas Stoerksen; Karlsen, Hans A.; Naevdal, Geir; Skaug, Hans J.; Valles, Brice

    2009-12-15

    The nonlinear filtering problem occurs in many scientific areas. Sequential Monte Carlo solutions with the correct asymptotic behavior such as particle filters exist but they are computationally too expensive when working with high-dimensional systems. The ensemble Kalman filter is a more robust method that has shown promising results with a small sample size but the samples are not guaranteed to come from the true posterior distribution. By approximating the model error with Gaussian kernels we get the advantage of both a Kalman correction and a weighting step. The resulting Gaussian mixture filter has the advantage of both a local Kalman type correction and the weighting/re sampling step of a particle filter. The Gaussian mixture approximation relies on a tunable bandwidth parameter which often has to be kept quite large in order to avoid weight collapse in high dimensions. As a result, the Kalman correction is too large to capture highly non-Gaussian posterior distributions. In this paper we have extended the Gaussian mixture filter (Hoteit et al., 2008b) and also made the connection to particle filters more transparent. In particular we introduce a tuning parameter for the importance weights. In the last part of the paper we have performed a simulation experiment with the Lorenz40 model where our method has been compared to the EnKF and a full implementation of a particle filter. The results clearly indicate that the new method has advantages compared to the standard EnKF. (Author)

  9. AER image filtering

    Science.gov (United States)

    Gómez-Rodríguez, F.; Linares-Barranco, A.; Paz, R.; Miró-Amarante, L.; Jiménez, G.; Civit, A.

    2007-05-01

    Address Event Representation (AER) is an emergent neuromorphic interchip communication protocol that allows real-time virtual massive connectivity among huge number of neurons located on different chips.[1] By exploiting high speed digital communication circuits (with nano-seconds timing), synaptic neural connections can be time multiplexed, while neural activity signals (with mili-seconds timings) are sampled at low frequencies. Neurons generate "events" according to their activity levels. That is, more active neurons generate more events per unit time and access the interchip communication channel more frequently than neurons with low activity. In Neuromorphic system development, AER brings some advantages to develop real-time image processing system: (1) AER represents the information like time continuous stream not like a frame; (2) AER sends the most important information first (although this depends on the sender); (3) AER allows to process information as soon as it is received. When AER is used in artificial vision field, each pixel is considered like a neuron, so pixel's intensity is represented like a sequence of events; modifying the number and the frequency of these events, it is possible to make some image filtering. In this paper we present four image filters using AER: (a) Noise addition and suppression, (b) brightness modification, (c) single moving object tracking and (d) geometrical transformations (rotation, translation, reduction and magnification). For testing and debugging, we use USB-AER board developed by Robotic and Technology of Computers Applied to Rehabilitation (RTCAR) research group. This board is based on an FPGA, devoted to manage the AER functionality. This board also includes a micro-controlled for USB communication, 2 Mbytes RAM and 2 AER ports (one for input and one for output).

  10. Particle Kalman Filtering: A Nonlinear Framework for Ensemble Kalman Filters

    KAUST Repository

    Hoteit, Ibrahim

    2010-09-19

    Optimal nonlinear filtering consists of sequentially determining the conditional probability distribution functions (pdf) of the system state, given the information of the dynamical and measurement processes and the previous measurements. Once the pdfs are obtained, one can determine different estimates, for instance, the minimum variance estimate, or the maximum a posteriori estimate, of the system state. It can be shown that, many filters, including the Kalman filter (KF) and the particle filter (PF), can be derived based on this sequential Bayesian estimation framework. In this contribution, we present a Gaussian mixture‐based framework, called the particle Kalman filter (PKF), and discuss how the different EnKF methods can be derived as simplified variants of the PKF. We also discuss approaches to reducing the computational burden of the PKF in order to make it suitable for complex geosciences applications. We use the strongly nonlinear Lorenz‐96 model to illustrate the performance of the PKF.

  11. Digital notch filter based active damping for LCL filters

    DEFF Research Database (Denmark)

    Yao, Wenli; Yang, Yongheng; Zhang, Xiaobin

    2015-01-01

    LCL filters are widely used in Pulse Width Modulation (PWM) inverters. However, it also introduces a pair of unstable resonant poles that may challenge the controller stability. The passive damping is a convenient possibility to tackle the resonance problem at the cost of system overall efficiency....... In this paper, a notch filter based active damping without the requirement of additional sensors is proposed, where the inverter current is employed as the feedback variable. Firstly, a design method of the notch filter for active damping is presented. The entire system stability has then been investigated......, which has revealed that negative variations of the resonant frequency can seriously affect the system stability. In order to make the controller more robust against grid impedance variations, the notch filter frequency is thus designed smaller than the LCL filter resonant frequency, which is done...

  12. Application of DFT Filter Banks and Cosine Modulated Filter Banks in Filtering

    Science.gov (United States)

    Lin, Yuan-Pei; Vaidyanathan, P. P.

    1994-01-01

    None given. This is a proposal for a paper to be presented at APCCAS '94 in Taipei, Taiwan. (From outline): This work is organized as follows: Sec. II is devoted to the construction of the new 2m channel under-decimated DFT filter bank. Implementation and complexity of this DFT filter bank are discussed therein. IN a similar manner, the new 2m channel cosine modulated filter bank is discussed in Sec. III. Design examples are given in Sec. IV.

  13. Implicit LES using adaptive filtering

    Science.gov (United States)

    Sun, Guangrui; Domaradzki, Julian A.

    2018-04-01

    In implicit large eddy simulations (ILES) numerical dissipation prevents buildup of small scale energy in a manner similar to the explicit subgrid scale (SGS) models. If spectral methods are used the numerical dissipation is negligible but it can be introduced by applying a low-pass filter in the physical space, resulting in an effective ILES. In the present work we provide a comprehensive analysis of the numerical dissipation produced by different filtering operations in a turbulent channel flow simulated using a non-dissipative, pseudo-spectral Navier-Stokes solver. The amount of numerical dissipation imparted by filtering can be easily adjusted by changing how often a filter is applied. We show that when the additional numerical dissipation is close to the subgrid-scale (SGS) dissipation of an explicit LES the overall accuracy of ILES is also comparable, indicating that periodic filtering can replace explicit SGS models. A new method is proposed, which does not require any prior knowledge of a flow, to determine the filtering period adaptively. Once an optimal filtering period is found, the accuracy of ILES is significantly improved at low implementation complexity and computational cost. The method is general, performing well for different Reynolds numbers, grid resolutions, and filter shapes.

  14. Level 3 filters at CDF

    International Nuclear Information System (INIS)

    Carroll, J.T.

    1985-01-01

    The Level 3 stage in CDF online filtering is currently under development. This system should support a flexible division between online and offline software filters within the constraints of the full data acquisition system. Multimicroprocessor (MMP) structures like the ACP system used by CDF could be improved with multi-rank architectures to meet SSC requirements

  15. Chopped filter for nuclear spectroscopy

    International Nuclear Information System (INIS)

    Koyama, J.

    1980-12-01

    Some of the theoretical and practical factors affecting the energy resolution of a spectrometry system are considered, specially those related to t he signal-to-noise ratio, and a time-variant filter with the transfer function of the theoretical optimum filter, during its active time, is proposed. A prototype has been tested and experimental results are presented. (Author) [pt

  16. Mobile filters in nuclear engineering

    International Nuclear Information System (INIS)

    Meuter, R.

    1979-01-01

    The need for filters with high efficiencies which may be used at any place originated in nuclear power plants. Filters of this type, called Filtermobil, have been developed by Sulzer. They have been used successfully in nuclear plants for several years. (orig.) [de

  17. Tunable Multiband Microwave Photonic Filters

    Directory of Open Access Journals (Sweden)

    Mable P. Fok

    2017-11-01

    Full Text Available The increasing demand for multifunctional devices, the use of cognitive wireless technology to solve the frequency resource shortage problem, as well as the capabilities and operational flexibility necessary to meet ever-changing environment result in an urgent need of multiband wireless communications. Spectral filter is an essential part of any communication systems, and in the case of multiband wireless communications, tunable multiband RF filters are required for channel selection, noise/interference removal, and RF signal processing. Unfortunately, it is difficult for RF electronics to achieve both tunable and multiband spectral filtering. Recent advancements of microwave photonics have proven itself to be a promising candidate to solve various challenges in RF electronics including spectral filtering, however, the development of multiband microwave photonic filtering still faces lots of difficulties, due to the limited scalability and tunability of existing microwave photonic schemes. In this review paper, we first discuss the challenges that were facing by multiband microwave photonic filter, then we review recent techniques that have been developed to tackle the challenge and lead to promising developments of tunable microwave photonic multiband filters. The successful design and implementation of tunable microwave photonic multiband filter facilitate the vision of dynamic multiband wireless communications and radio frequency signal processing for commercial, defense, and civilian applications.

  18. Diabatic initialization using recursive filters

    Science.gov (United States)

    Lynch, Peter; Huang, Xiang-Yu

    1994-10-01

    Several initialization schemes based on recursive filters are formulated and tested with a numerical weather prediction model, HIRLAM. These have an advantage over schemes which use non-recursive filters in that they derive the initialized values from a diabatic trajectory passing through the original analysis. The changes to the analysed fields are comparable in size to typical observational errors. A non-recursive implementation of the recursive filters makes the new initialization schemes as easy to use as the original non-recursive filter schemes. It also allows use of higher-order filters without added cost. An initialization method using a 6th order filter is compared to a scheme based on an non-recursive optimal filter, and is found to produce similar results for less than half the computational cost. If the sole aim is noise suppression, a filter whose output validates later than the initial time may be used. The advantage of this is that computation time is further reduced and phase error completely eliminated.

  19. Derivative free filtering using Kalmtool

    DEFF Research Database (Denmark)

    Bayramoglu, Enis; Hansen, Søren; Ravn, Ole

    2010-01-01

    In this paper we present a toolbox enabling easy evaluation and comparison of different filtering algorithms. The toolbox is called Kalmtool 4 and is a set of MATLAB tools for state estimation of nonlinear systems. The toolbox contains functions for extended Kalman filtering as well as for DD1 fi...

  20. Filters in Fuzzy Class Theory

    Czech Academy of Sciences Publication Activity Database

    Kroupa, Tomáš

    2008-01-01

    Roč. 159, č. 14 (2008), s. 1773-1787 ISSN 0165-0114 R&D Projects: GA MŠk 1M0572; GA AV ČR KJB100300502 Institutional research plan: CEZ:AV0Z10750506 Keywords : filter * prime filter * fuzzy class theory Subject RIV: BA - General Mathematics Impact factor: 1.833, year: 2008

  1. Approximately Liner Phase IIR Digital Filter Banks

    Directory of Open Access Journals (Sweden)

    J. D. Ćertić

    2013-11-01

    Full Text Available In this paper, uniform and nonuniform digital filter banks based on approximately linear phase IIR filters and frequency response masking technique (FRM are presented. Both filter banks are realized as a connection of an interpolated half-band approximately linear phase IIR filter as a first stage of the FRM design and an appropriate number of masking filters. The masking filters are half-band IIR filters with an approximately linear phase. The resulting IIR filter banks are compared with linear-phase FIR filter banks exhibiting similar magnitude responses. The effects of coefficient quantization are analyzed.

  2. On-line filtering

    International Nuclear Information System (INIS)

    Verkerk, C.

    1978-01-01

    Present day electronic detectors used in high energy physics make it possible to obtain high event rates and it is likely that future experiments will face even higher data rates than at present. The complexity of the apparatus increases very rapidly with time and also the criteria for selecting desired events become more and more complex. So complex in fact that the fast trigger system cannot be designed to fully cope with it. The interesting events become thus contaminated with multitudes of uninteresting ones. To distinguish the 'good' events from the often overwhelming background of other events one has to resort to computing techniques. Normally this selection is made in the first part of the analysis of the events, analysis normally performed on a powerful scientific computer. This implies however that many uninteresting or background events have to be recorded during the experiment for subsequent analysis. A number of undesired consequences result; and these constitute a sufficient reason for trying to perform the selection at an earlier stage, in fact ideally before the events are recorded on magnetic tape. This early selection is called 'on-line filtering' and it is the topic of the present lectures. (Auth.)

  3. Simplified design of filter circuits

    CERN Document Server

    Lenk, John

    1999-01-01

    Simplified Design of Filter Circuits, the eighth book in this popular series, is a step-by-step guide to designing filters using off-the-shelf ICs. The book starts with the basic operating principles of filters and common applications, then moves on to describe how to design circuits by using and modifying chips available on the market today. Lenk's emphasis is on practical, simplified approaches to solving design problems.Contains practical designs using off-the-shelf ICsStraightforward, no-nonsense approachHighly illustrated with manufacturer's data sheets

  4. Gas cleaning with Granular Filters

    OpenAIRE

    Natvig, Ingunn Roald

    2007-01-01

    The panel bed filter (PBF) is a granular filter patented by A. M. Squires in the late sixties. PBFs consist of louvers with stationary, granular beds. Dust is deposited in the top layers and on the bed surface when gas flows through. PBFs are resistant to high temperatures, variations in the gas flow and hot particles. The filter is cleaned by releasing a pressure pulse in the opposite direction of the bulk flow (a puff back pulse). A new louver geometry patented by A. M. Squires is the filte...

  5. Advanced simulation of digital filters

    Science.gov (United States)

    Doyle, G. S.

    1980-09-01

    An Advanced Simulation of Digital Filters has been implemented on the IBM 360/67 computer utilizing Tektronix hardware and software. The program package is appropriate for use by persons beginning their study of digital signal processing or for filter analysis. The ASDF programs provide the user with an interactive method by which filter pole and zero locations can be manipulated. Graphical output on both the Tektronix graphics screen and the Versatec plotter are provided to observe the effects of pole-zero movement.

  6. ADVANCED HOT GAS FILTER DEVELOPMENT

    Energy Technology Data Exchange (ETDEWEB)

    E.S. Connolly; G.D. Forsythe

    2000-09-30

    DuPont Lanxide Composites, Inc. undertook a sixty-month program, under DOE Contract DEAC21-94MC31214, in order to develop hot gas candle filters from a patented material technology know as PRD-66. The goal of this program was to extend the development of this material as a filter element and fully assess the capability of this technology to meet the needs of Pressurized Fluidized Bed Combustion (PFBC) and Integrated Gasification Combined Cycle (IGCC) power generation systems at commercial scale. The principal objective of Task 3 was to build on the initial PRD-66 filter development, optimize its structure, and evaluate basic material properties relevant to the hot gas filter application. Initially, this consisted of an evaluation of an advanced filament-wound core structure that had been designed to produce an effective bulk filter underneath the barrier filter formed by the outer membrane. The basic material properties to be evaluated (as established by the DOE/METC materials working group) would include mechanical, thermal, and fracture toughness parameters for both new and used material, for the purpose of building a material database consistent with what is being done for the alternative candle filter systems. Task 3 was later expanded to include analysis of PRD-66 candle filters, which had been exposed to actual PFBC conditions, development of an improved membrane, and installation of equipment necessary for the processing of a modified composition. Task 4 would address essential technical issues involving the scale-up of PRD-66 candle filter manufacturing from prototype production to commercial scale manufacturing. The focus would be on capacity (as it affects the ability to deliver commercial order quantities), process specification (as it affects yields, quality, and costs), and manufacturing systems (e.g. QA/QC, materials handling, parts flow, and cost data acquisition). Any filters fabricated during this task would be used for product qualification tests

  7. Pragmatic circuits signals and filters

    CERN Document Server

    Eccles, William

    2006-01-01

    Pragmatic Circuits: Signals and Filters is built around the processing of signals. Topics include spectra, a short introduction to the Fourier series, design of filters, and the properties of the Fourier transform. The focus is on signals rather than power. But the treatment is still pragmatic. For example, the author accepts the work of Butterworth and uses his results to design filters in a fairly methodical fashion. This third of three volumes finishes with a look at spectra by showing how to get a spectrum even if a signal is not periodic. The Fourier transform provides a way of dealing wi

  8. Face Recognition using Gabor Filters

    Directory of Open Access Journals (Sweden)

    Sajjad MOHSIN

    2011-01-01

    Full Text Available An Elastic Bunch Graph Map (EBGM algorithm is being proposed in this research paper that successfully implements face recognition using Gabor filters. The proposed system applies 40 different Gabor filters on an image. As aresult of which 40 images with different angles and orientation are received. Next, maximum intensity points in each filtered image are calculated and mark them as Fiducial points. The system reduces these points in accordance to distance between them. The next step is calculating the distances between the reduced points using distance formula. At last, the distances are compared with database. If match occurs, it means that the image is recognized.

  9. Remotely operated top loading filter housing

    International Nuclear Information System (INIS)

    Ross, M.J.; Carter, J.A.

    1989-01-01

    A high-efficiency particulate air (HEPA) filter system was developed for the Fuel Processing Facility at the Idaho Chemical Processing Plant. The system utilizes commercially available HEPA filters and allows in-cell filters to be maintained using operator-controlled remote handling equipment. The remote handling tasks include transport of filters before and after replacement, removal and replacement of the filter from the housing, and filter containment

  10. Concrete ensemble Kalman filters with rigorous catastrophic filter divergence.

    Science.gov (United States)

    Kelly, David; Majda, Andrew J; Tong, Xin T

    2015-08-25

    The ensemble Kalman filter and ensemble square root filters are data assimilation methods used to combine high-dimensional, nonlinear dynamical models with observed data. Ensemble methods are indispensable tools in science and engineering and have enjoyed great success in geophysical sciences, because they allow for computationally cheap low-ensemble-state approximation for extremely high-dimensional turbulent forecast models. From a theoretical perspective, the dynamical properties of these methods are poorly understood. One of the central mysteries is the numerical phenomenon known as catastrophic filter divergence, whereby ensemble-state estimates explode to machine infinity, despite the true state remaining in a bounded region. In this article we provide a breakthrough insight into the phenomenon, by introducing a simple and natural forecast model that transparently exhibits catastrophic filter divergence under all ensemble methods and a large set of initializations. For this model, catastrophic filter divergence is not an artifact of numerical instability, but rather a true dynamical property of the filter. The divergence is not only validated numerically but also proven rigorously. The model cleanly illustrates mechanisms that give rise to catastrophic divergence and confirms intuitive accounts of the phenomena given in past literature.

  11. Regenerable Carbon Filter, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — A Regenerable Carbon Filter (RCF) is proposed for the removal of carbonaceous particulate matter produced in Environmental Control and Life Support (ECLS) processes....

  12. Buffers and vegetative filter strips

    Science.gov (United States)

    Matthew J. Helmers; Thomas M. Isenhart; Michael G. Dosskey; Seth M. Dabney

    2008-01-01

    This chapter describes the use of buffers and vegetative filter strips relative to water quality. In particular, we primarily discuss the herbaceous components of the following NRCS Conservation Practice Standards.

  13. Dimensional reduction in nonlinear filtering

    Science.gov (United States)

    Park, J. H.; Sowers, R. B.; Sri Namachchivaya, N.

    2010-02-01

    The theory of nonlinear filtering forms the framework of many data assimilation problems. When the rates of change of different variables differ by orders of magnitude, efficient data assimilation can be accomplished by constructing nonlinear filtering equations for the coarse-grained signal. We consider the conditional law of a signal given the observations in a multi-scale context. In particular, we study how scaling interacts with filtering via stochastic averaging. This is an extension of our previous work (Park et al 2008 Stoch. Dyn. 8 543-60) where the observation process depended only on the fast variable, so the filter became independent of the observation in the limit. Here, we investigate a more realistic setting in which the observation depends on both the slow and the fast variables. Paper dedicated to Professor Manfred Denker on the occasion of his 65th birthday.

  14. Ion trajectories quadrupole mass filters

    International Nuclear Information System (INIS)

    Ursu, D.; Lupsa, N.; Muntean, F.

    1994-01-01

    The present paper aims at bringing some contributions to the understanding of ion motion in quadrupole mass filters. The theoretical treatment of quadrupole mass filter is intended to be a concise derivation of the important physical relationships using Mathieu functions. A simple iterative method of numerical computation has been used to simulate ion trajectories in an ideal quadrupole field. Finally, some examples of calculation are presented with the aid of computer graphics. (Author) 14 Figs., 1 Tab., 20 Refs

  15. Current Conveyor Based Multifunction Filter

    OpenAIRE

    Manish Kumar; M.C. Srivastava; Umesh Kumar

    2010-01-01

    The paper presents a current conveyor based multifunction filter. The proposed circuit can be realized as low pass, high pass, band pass and elliptical notch filter. The circuit employs two balanced output current conveyors, four resistors and two grounded capacitors, ideal for integration. It has only one output terminal and the number of input terminals may be used. Further, there is no requirement for component matching in the circuit. The parameter resonance frequency (\\omega_0) and bandw...

  16. Stochastic processes and filtering theory

    CERN Document Server

    Jazwinski, Andrew H

    1970-01-01

    This unified treatment of linear and nonlinear filtering theory presents material previously available only in journals, and in terms accessible to engineering students. Its sole prerequisites are advanced calculus, the theory of ordinary differential equations, and matrix analysis. Although theory is emphasized, the text discusses numerous practical applications as well.Taking the state-space approach to filtering, this text models dynamical systems by finite-dimensional Markov processes, outputs of stochastic difference, and differential equations. Starting with background material on probab

  17. Filter Fabrics for Airport Drainage.

    Science.gov (United States)

    1979-09-01

    pneumatically filling a woven polypropylene stocking with sand and vibrating it into a prebored hole, while another method uses a polyester nonwoven fabric...Selected Nonwoven Filter Fabrics," Letter Report, June 1977, U. S. Army Engineer Waterways Experiment Station, CE, Vicksburg, Miss. 18. BalL, J. E...woven and nonwoven plastic filter fabric. It has been developed based on limited field performance observations and the laboratory test evaluation of

  18. A quantum extended Kalman filter

    International Nuclear Information System (INIS)

    Emzir, Muhammad F; Woolley, Matthew J; Petersen, Ian R

    2017-01-01

    In quantum physics, a stochastic master equation (SME) estimates the state (density operator) of a quantum system in the Schrödinger picture based on a record of measurements made on the system. In the Heisenberg picture, the SME is a quantum filter. For a linear quantum system subject to linear measurements and Gaussian noise, the dynamics may be described by quantum stochastic differential equations (QSDEs), also known as quantum Langevin equations, and the quantum filter reduces to a so-called quantum Kalman filter. In this article, we introduce a quantum extended Kalman filter (quantum EKF), which applies a commutative approximation and a time-varying linearization to systems of nonlinear QSDEs. We will show that there are conditions under which a filter similar to a classical EKF can be implemented for quantum systems. The boundedness of estimation errors and the filtering problem with ‘state-dependent’ covariances for process and measurement noises are also discussed. We demonstrate the effectiveness of the quantum EKF by applying it to systems that involve multiple modes, nonlinear Hamiltonians, and simultaneous jump-diffusive measurements. (paper)

  19. Experience with three percutaneous vena cava filters

    International Nuclear Information System (INIS)

    McCowan, T.C.; Ferris, E.J.; Harshfield, D.L.; Hassell, D.R.; Baker, M.L.

    1987-01-01

    Twenty-one Kimray-Greenfield, 33 bird's nest, and 19 Amplatz vena cava filters were placed percutaneously. The Kimray-Greenfield filter was the most difficult to insert. The major problem was the insertion site, which required venipuncture with a 24-F catheter. Minor hemorrhage was frequent, and femoral vein thrombosis occurred in four patients. No migration, caval thrombosis, or pulmonary emboli were seen after Kimray-Greenfield filter placement. The bird's nest filter was relatively easy to insert, although in two cases the filter prongs could not be adequately seated in the wall of the inferior vena cava. Three patients with bird's nest filters had thrombosis below the filter, and three filters migrated to the heart. One migrated filter could not be removed. One patient had multiple small pulmonary emboli at autopsy. No other pulmonary emboli after filter placement were noted. The Amplatz filter was the easiest of the three filters to insert. Only one patient with an Amplatz filter had thrombosis of the vena cava below the filter. No filter migrations were documented, and no recurrent pulmonary emboli were found on clinical or radiologic follow-up. The Amplatz vena cava filter is easier to place than percutaneous Kimray-Greenfield or bird's nest filters, has a low complication rate, and has proven to be clinically effective in preventing pulmonary emboli

  20. Sensory pollution from bag-type fiberglass ventilation filters: Conventional filter compared with filters containing various amounts of activated carbon

    DEFF Research Database (Denmark)

    Bekö, Gabriel; Fadeyi, M.O.; Clausen, Geo

    2009-01-01

    was judged to be significantly better than the air downstream of the 6-month-old F7 filter, and was comparable to that from an unused F7 filter. Additionally, the combination filters removed more ozone from the air than the F7 filter, with their respective fractional removal efficiencies roughly scaling......As ventilation filters accumulate particles removed from the airstream, they become emitters of sensory pollutants that degrade indoor air quality. Previously we demonstrated that an F7 bag-type filter that incorporates activated carbon (a "combination filter") reduces this adverse effect compared...... to an equivalent filter without carbon. The aim of the present study was to examine how the amount of activated carbon (AC) used in combination filters affects their ability to remove both sensory offending pollutants and ozone. A panel evaluated the air downstream of four different filters after each had...

  1. Filter-adsorber aging assessment

    Energy Technology Data Exchange (ETDEWEB)

    Winegardner, W.K. [Pacific Northwest Laboratory, Richland, WA (United States)

    1995-02-01

    An aging assessment of high-efficiency particulate (HEPA) air filters and activated carbon gas adsorption units was performed by the Pacific Northwest Laboratory as part of the U.S. Nuclear Regulatory Commission`s (USNRC) Nuclear Plant Aging Research (NPAR) Program. This evaluation of the general process in which characteristics of these two components gradually change with time or use included the compilation of information concerning failure experience, stressors, aging mechanisms and effects, and inspection, surveillance, and monitoring methods (ISMM). Stressors, the agents or stimuli that can produce aging degradation, include heat, radiation, volatile contaminants, and even normal concentrations of aerosol particles and gasses. In an experimental evaluation of degradation in terms of the tensile breaking strength of aged filter media specimens, over forty percent of the samples did not meet specifications for new material. Chemical and physical reactions can gradually embrittle sealants and gaskets as well as filter media. Mechanisms that can lead to impaired adsorber performance are associated with the loss of potentially available active sites as a result of the exposure of the carbon to airborne moisture or volatile organic compounds. Inspection, surveillance, and monitoring methods have been established to observe filter pressure drop buildup, check HEPA filters and adsorbers for bypass, and determine the retention effectiveness of aged carbon. These evaluations of installed filters do not reveal degradation in terms of reduced media strength but that under normal conditions aged media can continue to effectively retain particles. However, this degradation may be important when considering the likelihood of moisture, steam, and higher particle loadings during severe accidents and the fact it is probable that the filters have been in use for an extended period.

  2. 21 CFR 211.72 - Filters.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 4 2010-04-01 2010-04-01 false Filters. 211.72 Section 211.72 Food and Drugs FOOD... shall not release fibers into such products. Fiber-releasing filters may be used when it is not possible to manufacture such products without the use of these filters. If use of a fiber-releasing filter is...

  3. Water washable stainless steel HEPA filter

    Science.gov (United States)

    Phillips, Terrance D.

    2001-01-01

    The invention is a high efficiency particulate (HEPA) filter apparatus and system, and method for assaying particulates. The HEPA filter provides for capture of 99.99% or greater of particulates from a gas stream, with collection of particulates on the surface of the filter media. The invention provides a filter system that can be cleaned and regenerated in situ.

  4. Unscented Kalman filtering for articulated human tracking

    DEFF Research Database (Denmark)

    Boesen Lindbo Larsen, Anders; Hauberg, Søren; Pedersen, Kim Steenstrup

    2011-01-01

    -of-the-art trackers utilize particle filters, our unimodal likelihood model allows us to use an unscented Kalman filter. This robust and efficient filter allows us to improve the quality of the tracker while using substantially fewer likelihood evaluations. The system is compared to one based on a particle filter...

  5. A class of orthogonal nonrecursive binomial filters.

    Science.gov (United States)

    Haddad, R. A.

    1971-01-01

    The time- and frequency-domain properties of the orthogonal binomial sequences are presented. It is shown that these sequences, or digital filters based on them, can be generated using adders and delay elements only. The frequency-domain behavior of these nonrecursive binomial filters suggests a number of applications as low-pass Gaussian filters or as inexpensive bandpass filters.

  6. Progress towards the use of disposable filters

    International Nuclear Information System (INIS)

    Macphail, I.

    1979-08-01

    Thermally degradable materials have been evaluated for service in HEPA filter units used to filter gases from active plants. The motivation was to reduce the bulk storage problems of contaminated filters by thermal decomposition to gaseous products and a solid residue substantially comprised of the filtered particulates. It is shown that while there are no commercially available alternatives to the glass fibre used in the filter medium, it would be feasible to manufacture the filter case and spacers from materials which could be incinerated. Operating temperatures, costs and the type of residues for disposal are discussed for filter case materials. (U.K.)

  7. A biological oil adsorption filter

    International Nuclear Information System (INIS)

    Pasila, A.

    2005-01-01

    A new oil adsorption method called adsorption filtration (AF) has been developed. It is a technology where by oil residues can be cleaned from water by running it through a simple filter made from freeze treated, dried, milled and then fragmented plant material. By choosing suitable plants and fragmentation sizes it is possible to produce filters, which pass water but adsorb oil. The aim of this study was to investigate the possibilities of manufacturing oil adsorbing filter materials from reed canary grass (Phalaris arundinacea), flax (Linum usitatissimum L.) or hemp fibre (Cannabis sativa L.). The oil (80 ml) was mixed with de-ionised water (200 ml) and this mixture was filtered through 10 or 20 g adsorption filters. Fine spring harvested hemp fibre (diameter less than 1 mm) and reed canary grass fragments adsorb 2-4 g of oil per gram of adsorption material compared to 1-3 g of water. Adsorption filtration is thus a novel way of gathering spilled oil in shallow coastal waters before the oil reaches the shore. (author)

  8. A biological oil adsorption filter

    Energy Technology Data Exchange (ETDEWEB)

    Pasila, A. [University of Helsinki (Finland). Dept. of Agricultural Engineering and Household Technology

    2005-12-01

    A new oil adsorption method called adsorption filtration (AF) has been developed. It is a technology where by oil residues can be cleaned from water by running it through a simple filter made from freeze treated, dried, milled and then fragmented plant material. By choosing suitable plants and fragmentation sizes it is possible to produce filters, which pass water but adsorb oil. The aim of this study was to investigate the possibilities of manufacturing oil adsorbing filter materials from reed canary grass (Phalaris arundinacea), flax (Linum usitatissimum L.) or hemp fibre (Cannabis sativa L.). The oil (80 ml) was mixed with de-ionised water (200 ml) and this mixture was filtered through 10 or 20 g adsorption filters. Fine spring harvested hemp fibre (diameter less than 1 mm) and reed canary grass fragments adsorb 2-4 g of oil per gram of adsorption material compared to 1-3 g of water. Adsorption filtration is thus a novel way of gathering spilled oil in shallow coastal waters before the oil reaches the shore. (author)

  9. Compact, Pneumatically Actuated Filter Shuttle

    Science.gov (United States)

    Leighy, Bradley D.

    2003-01-01

    A compact, pneumatically actuated filter shuttle has been invented to enable alternating imaging of a wind-tunnel model in two different spectral bands characteristic of the pressure and temperature responses of a pressure and temperature-sensitive paint. This filter shuttle could also be used in other settings in which there are requirements for alternating imaging in two spectral bands. Pneumatic actuation was chosen because of a need to exert control remotely (that is, from outside the wind tunnel) and because the power leads that would be needed for electrical actuation would pose an unacceptable hazard in the wind tunnel. The entire shuttle mechanism and its housing can be built relatively inexpensively [camera used for viewing the wind-tunnel model. The mechanism includes a pneumatic actuator connected to a linkage. The linkage converts the actuator stroke to a scissor-like motion that places one filter in front of the camera and the other filter out of the way. Optoelectronic sensors detect tabs on the sliding panels for verification of the proper positioning of the filters.

  10. A biological oil adsorption filter.

    Science.gov (United States)

    Pasila, Antti

    2004-12-01

    A new oil adsorption method called adsorption filtration (AF) has been developed. It is a technology where by oil residues can be cleaned from water by running it through a simple filter made from freeze treated, dried, milled and then fragmented plant material. By choosing suitable plants and fragmentation sizes it is possible to produce filters, which pass water but adsorb oil. The aim of this study was to investigate the possibilities of manufacturing oil adsorbing filter materials from reed canary grass (Phalaris arundinacea), flax (Linum usitatissimum L.) or hemp fibre (Cannabis sativa L.). The oil (80 ml) was mixed with de-ionised water (200 ml) and this mixture was filtered through 10 or 20 g adsorption filters. Fine spring harvested hemp fibre (diameter less than 1 mm) and reed canary grass fragments adsorb 2-4 g of oil per gram of adsorption material compared to 1-3 g of water. Adsorption filtration is thus a novel way of gathering spilled oil in shallow coastal waters before the oil reaches the shore.

  11. Testing HEPA filters with uranine

    International Nuclear Information System (INIS)

    Jalon, S.

    1987-01-01

    This paper reports experience gained at NASA's Goddard Space Flight Center in buying HEPA filters that were tested for efficiency without DOP. In preparing specifications for bid, we considered whether to test only a sample with DOP or to test every filter with some other aerosol. The choice of other aerosols was among air, salt, and uranine. The authors decided to specify that bidders choose between the British sodium flame test and the French uranine test or propose an acceptable alternative. One bidder proposed cutting an extra flap of paper off each filter, testing it with DOP, and checking the filter for leaks with air. The chosen supplier tested the efficiencies of his filters with uranine and counted the particles with a laser particle spectrometer. Part of this paper explains how the authors evaluated the different tests. The rest of it describes the test equipment, the upstream concentration and its constancy, the particle size distribution and its constancy, the penetration of different size particles, how discriminating the test was, and the issues that it raised

  12. Spectral filtering for plant production

    Energy Technology Data Exchange (ETDEWEB)

    Young, R.E.; McMahon, M.J.; Rajapakse, N.C.; Becoteau, D.R.

    1994-12-31

    Research to date suggests that spectral filtering can be an effective alternative to chemical growth regulators for altering plant development. If properly implemented, it can be nonchemical and environmentally friendly. The aqueous CuSO{sub 4}, and CuCl{sub 2} solutions in channelled plastic panels have been shown to be effective filters, but they can be highly toxic if the solutions contact plants. Some studies suggest that spectral filtration limited to short EOD intervals can also alter plant development. Future research should be directed toward confirmation of the influence of spectral filters and exposure times on a broader range of plant species and cultivars. Efforts should also be made to identify non-noxious alternatives to aqueous copper solutions and/or to incorporate these chemicals permanently into plastic films and panels that can be used in greenhouse construction. It would also be informative to study the impacts of spectral filters on insect and microbal populations in plant growth facilities. The economic impacts of spectral filtering techniques should be assessed for each delivery methodology.

  13. GPU Accelerated Vector Median Filter

    Science.gov (United States)

    Aras, Rifat; Shen, Yuzhong

    2011-01-01

    Noise reduction is an important step for most image processing tasks. For three channel color images, a widely used technique is vector median filter in which color values of pixels are treated as 3-component vectors. Vector median filters are computationally expensive; for a window size of n x n, each of the n(sup 2) vectors has to be compared with other n(sup 2) - 1 vectors in distances. General purpose computation on graphics processing units (GPUs) is the paradigm of utilizing high-performance many-core GPU architectures for computation tasks that are normally handled by CPUs. In this work. NVIDIA's Compute Unified Device Architecture (CUDA) paradigm is used to accelerate vector median filtering. which has to the best of our knowledge never been done before. The performance of GPU accelerated vector median filter is compared to that of the CPU and MPI-based versions for different image and window sizes, Initial findings of the study showed 100x improvement of performance of vector median filter implementation on GPUs over CPU implementations and further speed-up is expected after more extensive optimizations of the GPU algorithm .

  14. Multiplier-free filters for wideband SAR

    DEFF Research Database (Denmark)

    Dall, Jørgen; Christensen, Erik Lintz

    2001-01-01

    This paper derives a set of parameters to be optimized when designing filters for digital demodulation and range prefiltering in SAR systems. Aiming at an implementation in field programmable gate arrays (FPGAs), an approach for the design of multiplier-free filters is outlined. Design results ar...... are presented in terms of filter complexity and performance. One filter has been coded in VHDL and preliminary results indicate that the filter can meet a 2 GHz input sample rate....

  15. Fast algorithm for Morphological Filters

    International Nuclear Information System (INIS)

    Lou Shan; Jiang Xiangqian; Scott, Paul J

    2011-01-01

    In surface metrology, morphological filters, which evolved from the envelope filtering system (E-system) work well for functional prediction of surface finish in the analysis of surfaces in contact. The naive algorithms are time consuming, especially for areal data, and not generally adopted in real practice. A fast algorithm is proposed based on the alpha shape. The hull obtained by rolling the alpha ball is equivalent to the morphological opening/closing in theory. The algorithm depends on Delaunay triangulation with time complexity O(nlogn). In comparison to the naive algorithms it generates the opening and closing envelope without combining dilation and erosion. Edge distortion is corrected by reflective padding for open profiles/surfaces. Spikes in the sample data are detected and points interpolated to prevent singularities. The proposed algorithm works well both for morphological profile and area filters. Examples are presented to demonstrate the validity and superiority on efficiency of this algorithm over the naive algorithm.

  16. HEPA filter concerns - an overview

    Energy Technology Data Exchange (ETDEWEB)

    Leonard, J.F. [Department of Energy, Washington, DC (United States)

    1995-02-01

    The U.S. Department of Energy (DOE) recently initiated a complete review of the DOE High Efficiency Particulate Air (HEPA) Filter Program to identify areas for improvement. Although this process is currently ongoing, various issues and problems have already been identified for action that not only impacts the DOE HEPA filter program, but potentially the national and international air cleaning community as well. This paper briefly reviews a few of those concerns that may be of interest, and discusses actions initiated by the DOE to address the associated issues and problems. Issues discussed include: guidance standards, in-place testing, specifications, Test Facilities, portable units, vacuum cleaners, substitute aerosols, filter efficiencies, aging/shelf life/service life, fire suppression, handbook, Quality Products List (QPL), QA testing, and evaluations.

  17. Adaptive filtering primer with Matlab

    CERN Document Server

    Poularikas, Alexander D

    2006-01-01

    INTRODUCTIONSignal ProcessingAn ExampleOutline of the TextDISCRETE-TIME SIGNAL PROCESSINGDiscrete Time SignalsTransform-Domain Representation of Discrete-Time SignalsThe Z-TransformDiscrete-Time SystemsProblemsHints-Solutions-SuggestionsRANDOM VARIABLES, SEQUENCES, AND STOCHASTIC PROCESSESRandom Signals and DistributionsAveragesStationary ProcessesSpecial Random Signals and Probability Density FunctionsWiener-Khinchin RelationsFiltering Random ProcessesSpecial Types of Random ProcessesNonparametric Spectra EstimationParametric Methods of power Spectral EstimationProblemsHints-Solutions-SuggestionsWIENER FILTERSThe Mean-Square ErrorThe FIR Wiener FilterThe Wiener SolutionWiener Filtering ExamplesProblemsHints-Solutions-SuggestionsEIGENVALUES OF RX - PROPERTIES OF THE ERROR SURFACEThe Eigenvalues of the Correlation MatrixGeometrical Properties of the Error SurfaceProblemsHints-Solutions-SuggestionsNEWTON AND STEEPEST-DESCENT METHODOne-Dimensional Gradient Search MethodSteepest-Descent AlgorithmProblemsHints-Sol...

  18. Applications of nonwoven filter media

    Energy Technology Data Exchange (ETDEWEB)

    1988-11-01

    The multi-client technical and marketing report, Nonwovens in Filtration (1987) World Wide, has been completed by Filter Media Consulting, Inc. According to this 450-page report, $818 million in sales worldwide in nonwoven filter media represents a substantial segment of the entire nonwoven market. This total is mainly roll goods with a few exceptions. Meltblown composites represent $108 million, 13% of the total, and is the fastest growing segment as compared to needled felts, dry formed, thermobonded, spunbonded, wet laid and other unique processes, all extensively covered in this report. Included are 20 filtration applications covered in 190 pages, such as baghouse and dust filtration, Torit-type cartridge filters, HEPA/ULPA filtration, and heating, ventilation and air conditioning. Major markets are addressed, and trends in different fields are highlighted throughout the report.

  19. Adaptive filtering prediction and control

    CERN Document Server

    Goodwin, Graham C

    2009-01-01

    Preface1. Introduction to Adaptive TechniquesPart 1. Deterministic Systems2. Models for Deterministic Dynamical Systems3. Parameter Estimation for Deterministic Systems4. Deterministic Adaptive Prediction5. Control of Linear Deterministic Systems6. Adaptive Control of Linear Deterministic SystemsPart 2. Stochastic Systems7. Optimal Filtering and Prediction8. Parameter Estimation for Stochastic Dynamic Systems9. Adaptive Filtering and Prediction10. Control of Stochastic Systems11. Adaptive Control of Stochastic SystemsAppendicesA. A Brief Review of Some Results from Systems TheoryB. A Summary o

  20. Filter-extruded liposomes revisited

    DEFF Research Database (Denmark)

    Hinna, Askell; Steiniger, Frank; Hupfeld, Stefan

    2016-01-01

    (pore-size, number of filter passages, and flow-rate), flow field-flow fractionation in conjunction with multi-angle laser light scattering (AF4-MALLS, Wyatt Technology Corp., Santa Barbara, CA) was employed. Liposome size-distributions determined by AF4-MALLS were compared with those of dynamic light...... is suggested to prepare large (300 nm) liposomes with rather narrow size distribution, based on the filter extrusion at defined flow-rates in combination with freeze-/ thaw-cycling and bench-top centrifugation....

  1. Quantized, piecewise linear filter network

    DEFF Research Database (Denmark)

    Sørensen, John Aasted

    1993-01-01

    A quantization based piecewise linear filter network is defined. A method for the training of this network based on local approximation in the input space is devised. The training is carried out by repeatedly alternating between vector quantization of the training set into quantization classes...... and equalization of the quantization classes linear filter mean square training errors. The equalization of the mean square training errors is carried out by adapting the boundaries between neighbor quantization classes such that the differences in mean square training errors are reduced...

  2. In Situ Cleanable Alternative HEPA Filter Media

    International Nuclear Information System (INIS)

    Adamson, D. J.; Terry, M. T.

    2002-01-01

    The Westinghouse Savannah River Company, located at the Savannah River Site in Aiken, South Carolina, is currently testing two types of filter media for possible deployment as in situ regenerable/cleanable High Efficiency Particulate Air (HEPA) filters. The filters are being investigated to replace conventional, disposable, glass-fiber, HEPA filters that require frequent removal, replacement, and disposal. This is not only costly and subjects site personnel to radiation exposure, but adds to the ever-growing waste disposal problem. The types of filter media being tested, as part of a National Energy Technology Laboratory procurement, are sintered nickel metal and ceramic monolith membrane. These media were subjected to a hostile environment to simulate conditions that challenge the high-level waste tank ventilation systems. The environment promoted rapid filter plugging to maximize the number of filter loading/cleaning cycles that would occur in a specified period of time. The filters were challenged using nonradioactive simulated high-level waste materials and atmospheric dust; materials that cause filter pluggage in the field. The filters are cleaned in situ using an aqueous solution. The study found that both filter media were insensitive to high humidity or moisture conditions and were easily cleaned in situ. The filters regenerated to approximately clean filter status even after numerous plugging and in situ cleaning cycles. Air Techniques International is conducting particle retention testing on the filter media at the Oak Ridge Filter Test Facility. The filters are challenged using 0.3-mm di-octyl phthalate particles. Both the ceramic and sintered media have a particle retention efficiency > 99.97%. The sintered metal and ceramic filters not only can be cleaned in situ, but also hold great potential as a long life alternative to conventional HEPA filters. The Defense Nuclear Facility Safety Board Technical Report, ''HEPA Filters Used in the Department of

  3. Filtering Undesirable Flows in Networks

    NARCIS (Netherlands)

    Polevoy, G.; Trajanovski, S.; Grosso, P.; de Laat, C.; Gao, X.; Du, H.; Han, M.

    2017-01-01

    We study the problem of fully mitigating the effects of denial of service by filtering the minimum necessary set of the undesirable flows. First, we model this problem and then we concentrate on a subproblem where every good flow has a bottleneck. We prove that unless P=NP, this subproblem is

  4. Spectral Diagonal Ensemble Kalman Filters

    Czech Academy of Sciences Publication Activity Database

    Kasanický, Ivan; Mandel, Jan; Vejmelka, Martin

    2015-01-01

    Roč. 22, č. 4 (2015), s. 485-497 ISSN 1023-5809 R&D Projects: GA ČR GA13-34856S Grant - others:NSF(US) DMS -1216481 Institutional support: RVO:67985807 Keywords : data assimilation * ensemble Kalman filter * spectral representation Subject RIV: DG - Athmosphere Sciences, Meteorology Impact factor: 1.321, year: 2015

  5. Radioactive liquid waste filtering device

    International Nuclear Information System (INIS)

    Inami, Ichiro; Tabata, Masayuki; Kubo, Koji.

    1988-01-01

    Purpose: To prevent clogging in filter materials and improve the filtration performance for radioactive liquid wastes without increasing the amount of radioactive wastes. Constitution: In a radioactive waste filtering device, a liquid waste recycling pipe and a liquid recycling pump are disposed for recycling the radioactive liquid wastes in a liquid wastes vessel. In this case, the recycling pipe and the recycling pump are properly selected so as to satisfy the conditions capable of making the radioactive liquid wastes flowing through the pipe to have the Reynolds number of 10 4 - 10 5 . By repeating the transportation of radioactive liquid wastes in the liquid waste vessel through the liquid waste recycling pipe by the liquid waste recycling pump and then returning them to the liquid waste vessel again, particles of fine grain size in the suspended liquids are coagulated with each other upon collision to increase the grain size of the suspended particles. In this way, clogging of the filter materials caused by the particles of fine grain size can be prevented, thereby enabling to prevent the increase in the rising rate of the filtration differential pressure, reduce the frequency for the occurrence of radioactive wastes such as filter sludges and improve the processing performance. (Kamimura, M.)

  6. Visualizing the application of filters

    DEFF Research Database (Denmark)

    Rasmussen, Rasmus; Hertzum, Morten

    2013-01-01

    Through a mixed-design experiment we compare how emergency-department clinicians perform when solving realistic work tasks with an electronic whiteboard where the application of information filters is visualized either by blocking, colour-coding or blurring information. We find that clinicians pe...

  7. Performance comparison of various time variant filters

    Energy Technology Data Exchange (ETDEWEB)

    Kuwata, M. [JEOL Engineering Co. Ltd., Akishima, Tokyo (Japan); Husimi, K.

    1996-07-01

    This paper describes the advantage of the trapezoidal filter used in semiconductor detector system comparing with the other time variant filters. The trapezoidal filter is the compose of a rectangular pre-filter and a gated integrator. We indicate that the best performance is obtained by the differential-integral summing type rectangular pre-filter. This filter is not only superior in performance, but also has the useful feature that the rising edge of the output waveform is linear. We introduce an example of this feature used in a high-energy experiment. (author)

  8. Design and construction of electronic filters

    International Nuclear Information System (INIS)

    Becerril Z, E.R.; Moreno P, C.; Salinas B, E.

    1979-01-01

    The design and construction of very low frequencies electronic filters which will be used for carrying out analysis of pile noise at Mexico's Nuclear Center Triga Mark III Reactor, in order to realize measurements of its parameters is presented. NIM norms and active filters with lineal integrated circuits were used: a. Band pass filter from 10 to 500 hertz, band width 50. b. Low pass filter from 0.001 to 10 hertz in 3 steps. c. Kalman Bucy filter, an analogical simulation of this filter was undertaken, obtained from a mathematical model of a Zero power experimental reactor, with the purpose to establish a control searching. (author)

  9. Bottom loaded filter for radioactive liquids

    International Nuclear Information System (INIS)

    Wendland, W.G.

    1983-01-01

    This invention relates to equipment for filtering liquids and more particularly to filter assemblies for use with radioactive by-products of nuclear power plants. The invention provides a compact, bottom-loaded filter assembly that can be quickly and safely loaded and unloaded without the use of complex remote equipment. The assembly is integrally shielded and does not require external shielding. The closure hatch may be automatically aligned to facilitate quick sealing attachment after replacement of the filter cartridge, and the filter cartridge may be automatically positioned within the filter housing during the replacement operation

  10. High temperature filter for incinerator gas purification

    International Nuclear Information System (INIS)

    Billard, Francois; Brion, Jacques; Cousin, Michel; Delarue, Roger

    1969-01-01

    This note describes a regenerable filter for the hot filtering of incinerator gases. The filter is made of several wire gauze candles coated with asbestos fibers as filtering medium. Unburnt products, like carbon black, terminate their combustion on the filter, reducing the risk of clogging and enhancing the operation time to several hundreds of hours between two regeneration cycles. The filter was tested on a smaller scale mockup, and then on an industrial pilot plant with a 20 kg/h capacity during a long duration. This note describes the installation and presents the results obtained [fr

  11. A rigid porous filter and filtration method

    Energy Technology Data Exchange (ETDEWEB)

    Chiang, Ta-Kuan; Straub, Douglas, Straub L.; Dennis, Richard A.

    1998-12-01

    The present invention involves a porous rigid filter comprising a plurality of concentric filtration elements having internal flow passages and forming external flow passages there between. The present invention also involves a pressure vessel containing the filter for the removal of particulate from high pressure particulate containing gases, and further involves a method for using the filter to remove such particulate. The present filter has the advantage of requiring fewer filter elements due to the high surface area- to-volume ratio provided by the filter, requires a reduced pressure vessel size, and exhibits enhanced mechanical design properties, improved cleaning properties, configuration options, modularity and ease of fabrication.

  12. Uniformidade de distribuição do potássio e do nitrogênio em sistema de irrigação por gotejamento Evaluation of potassium and nitrogen distribution uniformity in trickle irrigation system

    Directory of Open Access Journals (Sweden)

    Marcus V. A. M. de Oliveira

    2008-03-01

    Full Text Available O uso da fertirrigação possibilita a obtenção de bons resultados, todavia é notada a necessidade de trabalhos que venham possibilitar a adoção correta da técnica. Dessa forma ,o presente trabalho buscou comparar a uniformidade de distribuição do potássio e do nitrogênio em sistema de irrigação por gotejamento. A solução de fertilizantes foi injetada durante 25 minutos, sendo recolhidas amostras de solução em diferentes momentos, durante e após ter sido finalizada a operação de injeção, tendo sido especificado o tempo de 35 minutos após o início da operação de injeção da solução de fertilizantes, como tempo-limite para a coleta da última amostra. As amostras coletadas tiveram os teores de potássio (K+ e nitrogênio (NO3- + NH4+ determinados. Com os resultados obtidos, concluiu-se que não houve variação significativa da uniformidade de distribuição de nitrogênio e de potássio no sistema de irrigação por gotejamento; maiores tempos de funcionamento de sistemas de irrigação, quando em operação de fertirrigação, possibilitam melhores uniformidades de distribuição do fertilizante, e deve-se calcular o tempo de lavagem do sistema de irrigação, pois é uma forma de melhorar a uniformidade de distribuição do fertilizante no campo.The use of the fertigation makes possible obtaining good results; however it was noticed the necessity of studies that make possible the correct adoption of this technique. Thus the present study aimed to compare the distribution uniformity of potassium and nitrogen when applied through a trickle irrigation system. The fertilizers solution was applied during 25 minutes; samples of solution were collected at different moments during and after the product injection through irrigation water, and the time limit to collect the last sample was specified as 35 minutes after injection operations begun. In the collected samples were determined the contents of potassium (K+ and

  13. Marginalized Particle Filtering Framework for Tuning of Ensemble Filters

    Czech Academy of Sciences Publication Activity Database

    Šmídl, Václav; Hofman, Radek

    2011-01-01

    Roč. 139, č. 11 (2011), s. 3589-3599 ISSN 0027-0644 R&D Projects: GA MV VG20102013018; GA ČR GP102/08/P250 Institutional research plan: CEZ:AV0Z10750506 Keywords : ensemble finter * marginalized particle filter * data assimilation Subject RIV: BB - Applied Statistics, Operational Research Impact factor: 2.688, year: 2011 http://library.utia.cas.cz/separaty/2011/AS/smidl-0367533.pdf

  14. A Study of Parallel Operation of an active Filter and passive Filters

    DEFF Research Database (Denmark)

    Chen, Zhe; Blaabjerg, Frede; Pedersen, John Kim

    2002-01-01

    This paper reports investigations of the parallel operations of a current controlled active filter and passive filters in a system with current harmonic sources. The task of reactive power and harmonic compensation is shared by the active filter and passive filters. The passive filters are used...... arrangements of the active and passive filters can operate relatively independently, also the compensation flexibility of the active filter can be fully exploited, such as one active filter for several harmonic sources.The simulation studies on various systems have been performed to evaluate the effectiveness...... of the systems. The results show that the power factor is corrected by the passive filters, harmonics are minimized by both active and passive filters and overloading of the filter system can be avoided....

  15. Optimized FPGA Implementation of Multi-Rate FIR Filters Through Thread Decomposition

    Science.gov (United States)

    Kobayashi, Kayla N.; He, Yutao; Zheng, Jason X.

    2011-01-01

    Multi-rate finite impulse response (MRFIR) filters are among the essential signal-processing components in spaceborne instruments where finite impulse response filters are often used to minimize nonlinear group delay and finite precision effects. Cascaded (multistage) designs of MRFIR filters are further used for large rate change ratio in order to lower the required throughput, while simultaneously achieving comparable or better performance than single-stage designs. Traditional representation and implementation of MRFIR employ polyphase decomposition of the original filter structure, whose main purpose is to compute only the needed output at the lowest possible sampling rate. In this innovation, an alternative representation and implementation technique called TD-MRFIR (Thread Decomposition MRFIR) is presented. The basic idea is to decompose MRFIR into output computational threads, in contrast to a structural decomposition of the original filter as done in the polyphase decomposition. A naive implementation of a decimation filter consisting of a full FIR followed by a downsampling stage is very inefficient, as most of the computations performed by the FIR state are discarded through downsampling. In fact, only 1/M of the total computations are useful (M being the decimation factor). Polyphase decomposition provides an alternative view of decimation filters, where the downsampling occurs before the FIR stage, and the outputs are viewed as the sum of M sub-filters with length of N/M taps. Although this approach leads to more efficient filter designs, in general the implementation is not straightforward if the numbers of multipliers need to be minimized. In TD-MRFIR, each thread represents an instance of the finite convolution required to produce a single output of the MRFIR. The filter is thus viewed as a finite collection of concurrent threads. Each of the threads completes when a convolution result (filter output value) is computed, and activated when the first

  16. Programmable Baseband Filter for Multistandard Mobile Phones

    DEFF Research Database (Denmark)

    Jensen, Rasmus Glarborg; Christensen, Kåre Tais; Bruun, Erik

    2003-01-01

    This paper describes a channel selection filter for mobile communication systems using a direct down conversion architecture. The filter can be programmed to meet the requirements of different communication standards, including GSM (Global System for Mobile communication), WCDMA (Wideband Code...

  17. Deep Ultraviolet Macroporous Silicon Filters, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — This SBIR Phase I proposal describes a novel method to make deep and far UV optical filters from macroporous silicon. This type of filter consists of an array of...

  18. Blocking Detection Based on Synoptic Filters

    Directory of Open Access Journals (Sweden)

    Bernd Schalge

    2011-01-01

    minimum zonal width, and (iii a persistence filter to extract events with a minimum duration. Practical filter application is analysed in two case studies and the blocking climatologies for the Northern and the Southern Hemisphere.

  19. Cryptosporidium: A Guide to Water Filters

    Science.gov (United States)

    ... Cryptosporidium Tracking in the United States CryptoNet Healthy Water Sites Healthy Water Drinking Water Healthy Swimming Global ... lt;/label> Parasites Home A Guide to Water Filters Recommend on Facebook Tweet Share Compartir Filtering ...

  20. Kalman filtering with real-time applications

    CERN Document Server

    Chui, Charles K

    2017-01-01

    This new edition presents a thorough discussion of the mathematical theory and computational schemes of Kalman filtering. The filtering algorithms are derived via different approaches, including a direct method consisting of a series of elementary steps, and an indirect method based on innovation projection. Other topics include Kalman filtering for systems with correlated noise or colored noise, limiting Kalman filtering for time-invariant systems, extended Kalman filtering for nonlinear systems, interval Kalman filtering for uncertain systems, and wavelet Kalman filtering for multiresolution analysis of random signals. Most filtering algorithms are illustrated by using simplified radar tracking examples. The style of the book is informal, and the mathematics is elementary but rigorous. The text is self-contained, suitable for self-study, and accessible to all readers with a minimum knowledge of linear algebra, probability theory, and system engineering. Over 100 exercises and problems with solutions help de...

  1. Media filter drain : modified design evaluation.

    Science.gov (United States)

    2014-09-01

    The media filter drain (MFD), a stormwater water quality treatment best management practice, consists of media made up of : aggregate, perlite, gypsum and dolomite in a trench located along roadway shoulders with gravel and vegetative pre-filtering f...

  2. A new martingale approach to Kalman Filtering

    NARCIS (Netherlands)

    Bagchi, Arunabha

    1976-01-01

    A new derivation of continuous-time Kalman Filter equations is presented. The underlying idea has been previously used to derive the smoothing equations. A unified approach to filtering and smoothing problems has thus been achieved.

  3. Penetration of superfluid turbulence through porous filters

    International Nuclear Information System (INIS)

    Foreman, L.R.; Snyder, H.A.

    1979-01-01

    The equilibrium concentration of superfluid turbulence on two sides of small-pore filters is studied as a function of pore size. The filter forms a common wall between two second-sound resonance cavities. The attenuation of standing waves of second sound is used to detect the turbulence which is created in the superfluid with a rotating paddle. We find that superfluid turbulence does not pass through filters of 7.5 nm diameter, but penetrates filters with 50-nm pores

  4. Mixtures of skewed Kalman filters

    KAUST Repository

    Kim, Hyoungmoon

    2014-01-01

    Normal state-space models are prevalent, but to increase the applicability of the Kalman filter, we propose mixtures of skewed, and extended skewed, Kalman filters. To do so, the closed skew-normal distribution is extended to a scale mixture class of closed skew-normal distributions. Some basic properties are derived and a class of closed skew. t distributions is obtained. Our suggested family of distributions is skewed and has heavy tails too, so it is appropriate for robust analysis. Our proposed special sequential Monte Carlo methods use a random mixture of the closed skew-normal distributions to approximate a target distribution. Hence it is possible to handle skewed and heavy tailed data simultaneously. These methods are illustrated with numerical experiments. © 2013 Elsevier Inc.

  5. Nonlinear image filtering within IDP++

    Energy Technology Data Exchange (ETDEWEB)

    Lehman, S.K.; Wieting, M.G.; Brase, J.M.

    1995-02-09

    IDP++, image and data processing in C++, is a set of a signal processing libraries written in C++. It is a multi-dimension (up to four dimensions), multi-data type (implemented through templates) signal processing extension to C++. IDP++ takes advantage of the object-oriented compiler technology to provide ``information hiding.`` Users need only know C, not C++. Signals or data sets are treated like any other variable with a defined set of operators and functions. We here some examples of the nonlinear filter library within IDP++. Specifically, the results of MIN, MAX median, {alpha}-trimmed mean, and edge-trimmed mean filters as applied to a real aperture radar (RR) and synthetic aperture radar (SAR) data set.

  6. Ceramic hot-gas filter

    Science.gov (United States)

    Connolly, Elizabeth Sokolinski; Forsythe, George Daniel; Domanski, Daniel Matthew; Chambers, Jeffrey Allen; Rajendran, Govindasamy Paramasivam

    1999-01-01

    A ceramic hot-gas candle filter having a porous support of filament-wound oxide ceramic yarn at least partially surrounded by a porous refractory oxide ceramic matrix, and a membrane layer on at least one surface thereof. The membrane layer may be on the outer surface, the inner surface, or both the outer and inner surface of the porous support. The membrane layer may be formed of an ordered arrangement of circularly wound, continuous filament oxide ceramic yarn, a ceramic filler material which is less permeable than the filament-wound support structure, or some combination of continuous filament and filler material. A particularly effective membrane layer features circularly wound filament with gaps intentionally placed between adjacent windings, and a filler material of ceramic particulates uniformly distributed throughout the gap region. The filter can withstand thermal cycling during backpulse cleaning and is resistant to chemical degradation at high temperatures.

  7. Filters: It's Not about Porn, Stupid!

    Science.gov (United States)

    Schuyler, Michael

    1997-01-01

    Discusses libraries' uses of filters to prevent access to objectionable sites on the Internet. Highlights include the American Library Association's resolution against filters as a violation of First Amendment rights; patron's use of terminals for e-mail or games; using filters for collection management; and listservs and online resources…

  8. Notch filters for port-Hamiltonian systems

    NARCIS (Netherlands)

    Dirksz, D.A.; Scherpen, J.M.A.; van der Schaft, A.J.; Steinbuch, M.

    2012-01-01

    In this paper a standard notch filter is modeled in the port-Hamiltonian framework. By having such a port-Hamiltonian description it is proven that the notch filter is a passive system. The notch filter can then be interconnected with another (nonlinear) port-Hamiltonian system, while preserving the

  9. B Plant exhaust filter inventory analysis

    International Nuclear Information System (INIS)

    Lan, J.S.; Wootan, D.W.; Carter, L.L.; Bunch, W.L.; Covey, L.I.; Greenborg, J.

    1994-10-01

    This paper describes a method for determining radionuclide inventories in filters using measurements of radiation fields that determine photon dose rates and photon-plus-electron dose rates between filter banks. The mathematical approach quantifies the curie inventories of filter banks by using the measured dose rates and the calculated Green's functions involving detector responses per unit source

  10. In situ microbial filter used for bioremediation

    Science.gov (United States)

    Carman, M. Leslie; Taylor, Robert T.

    2000-01-01

    An improved method for in situ microbial filter bioremediation having increasingly operational longevity of an in situ microbial filter emplaced into an aquifer. A method for generating a microbial filter of sufficient catalytic density and thickness, which has increased replenishment interval, improved bacteria attachment and detachment characteristics and the endogenous stability under in situ conditions. A system for in situ field water remediation.

  11. Gradient based filtering of digital elevation models

    DEFF Research Database (Denmark)

    Knudsen, Thomas; Andersen, Rune Carbuhn

    We present a filtering method for digital terrain models (DTMs). The method is based on mathematical morphological filtering within gradient (slope) defined domains. The intention with the filtering procedure is to improbé the cartographic quality of height contours generated from a DTM based on ...

  12. Liquid filter for liquids containing radioactive materials

    International Nuclear Information System (INIS)

    Rohleder, N.; Schwarz, F.

    1986-01-01

    A device for filtering radioactive liquids loaded with solids is described, which has a pressure-resistant housing with a lid and an incomer for the turbid liquid and a collecting space and drain for the filtrate at the bottom of the housing. A filter cartridge is present in this housing. Such a filtering device must be suitable for use in nuclear plants, must be easy to replace by remote control and must minimise the carrying over of radioactive particles. This problem should be solved by the filter cartridge consisting of a large number of horizontal filter plates stacked above one another, which carry a deep layer filter material acting in the sub-micron range. The turbid liquid runs into the centre of the stack of filter plates via a vertical central duct. The intermediate spaces between the filter places are connected to this central duct via the layer of filter material. The filter plates are sealed against one another on the outer circumference and have radial drain openings for the filtrate on the outside. The central duct is sealed at the lower end by a plate. When the filter cartridge is replaced, the radioactive waste in the filter cartridge remains safely enclosed and can be conditioned in suitable containers. (orig.) [de

  13. Electrically heated particulate filter restart strategy

    Science.gov (United States)

    Gonze, Eugene V [Pinckney, MI; Ament, Frank [Troy, MI

    2011-07-12

    A control system that controls regeneration of a particulate filter is provided. The system generally includes a propagation module that estimates a propagation status of combustion of particulate matter in the particulate filter. A regeneration module controls current to the particulate filter to re-initiate regeneration based on the propagation status.

  14. 27 CFR 24.243 - Filtering aids.

    Science.gov (United States)

    2010-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2010-04-01 2010-04-01 false Filtering aids. 24.243... OF THE TREASURY LIQUORS WINE Storage, Treatment and Finishing of Wine § 24.243 Filtering aids. Inert fibers, pulps, earths, or similar materials, may be used as filtering aids in the cellar treatment and...

  15. RETENTION OF SULFUR DIOXIDE BY NYLON FILTERS

    Science.gov (United States)

    Based on laboratory studies, recovery efficiencies of sulfur dioxide (SO2) were determined for nylon filters. The nylon filters used in these experiments were found to retain SO2. A relatively uniform amount (1.7%) was recoverable from each nylon filter, independent of relative...

  16. Fuzzy t-filters and their Properties

    Czech Academy of Sciences Publication Activity Database

    Víta, Martin

    2014-01-01

    Roč. 247, 16 July (2014), s. 127-134 ISSN 0165-0114 R&D Projects: GA ČR GAP202/10/1826 Institutional support: RVO:67985807 Keywords : non-classical logics * algebra * fuzzy t-filters * t-filters * fuzzy filters * residuated lattices Subject RIV: BA - General Mathematics Impact factor: 1.986, year: 2014

  17. HF filter design and computer simulation

    CERN Document Server

    Rhea, Randall W

    1994-01-01

    A book for engineers who design and build filters of all types, including lumped element, coaxial, helical, dielectric resonator, stripline and microstrip types. A thorough review of classic and modern filter design techniques, containing extensive practical design information of passband characteristics, topologies and transformations, component effects and matching. An excellent text for the design and construction of microstrip filters.

  18. Simulasi Filter Pasif Dan Perbandingan Unjuk Kerjanya Dengan Filter Aktif Dan Filter Aktif Hibrid Dalam Meredam Harmonisa Pada Induction Furnace

    OpenAIRE

    Tanoto, Yusak; Limantara, Limboto; Khandy Lestanto, Khristian

    2005-01-01

    This paper describe about simulation of Passive Filter in analysis to reduce harmonics that happened in a load such as vacuum casting induction furnace 9 kW, 13.8 kVA, 200V, 3 Ph, 50/60 Hz, also gives comparison with Hybrid Active Filter and Active Filter which made satisfaction result on the previous research. The best result achieved on the use of Hybrid Active Filter on %ITHD for 4.27 % and %VTHD for 3.83%, while Active Filter gave on %ITHD for 5.14 % and %VTHD for 3.82%. There ...

  19. Filtering algorithm for dotted interferences

    Energy Technology Data Exchange (ETDEWEB)

    Osterloh, K., E-mail: kurt.osterloh@bam.de [Federal Institute for Materials Research and Testing (BAM), Division VIII.3, Radiological Methods, Unter den Eichen 87, 12205 Berlin (Germany); Buecherl, T.; Lierse von Gostomski, Ch. [Technische Universitaet Muenchen, Lehrstuhl fuer Radiochemie, Walther-Meissner-Str. 3, 85748 Garching (Germany); Zscherpel, U.; Ewert, U. [Federal Institute for Materials Research and Testing (BAM), Division VIII.3, Radiological Methods, Unter den Eichen 87, 12205 Berlin (Germany); Bock, S. [Technische Universitaet Muenchen, Lehrstuhl fuer Radiochemie, Walther-Meissner-Str. 3, 85748 Garching (Germany)

    2011-09-21

    An algorithm has been developed to remove reliably dotted interferences impairing the perceptibility of objects within a radiographic image. This particularly is a major challenge encountered with neutron radiographs collected at the NECTAR facility, Forschungs-Neutronenquelle Heinz Maier-Leibnitz (FRM II): the resulting images are dominated by features resembling a snow flurry. These artefacts are caused by scattered neutrons, gamma radiation, cosmic radiation, etc. all hitting the detector CCD directly in spite of a sophisticated shielding. This makes such images rather useless for further direct evaluations. One approach to resolve this problem of these random effects would be to collect a vast number of single images, to combine them appropriately and to process them with common image filtering procedures. However, it has been shown that, e.g. median filtering, depending on the kernel size in the plane and/or the number of single shots to be combined, is either insufficient or tends to blur sharp lined structures. This inevitably makes a visually controlled processing image by image unavoidable. Particularly in tomographic studies, it would be by far too tedious to treat each single projection by this way. Alternatively, it would be not only more comfortable but also in many cases the only reasonable approach to filter a stack of images in a batch procedure to get rid of the disturbing interferences. The algorithm presented here meets all these requirements. It reliably frees the images from the snowy pattern described above without the loss of fine structures and without a general blurring of the image. It consists of an iterative, within a batch procedure parameter free filtering algorithm aiming to eliminate the often complex interfering artefacts while leaving the original information untouched as far as possible.

  20. Social Collaborative Filtering by Trust.

    Science.gov (United States)

    Yang, Bo; Lei, Yu; Liu, Jiming; Li, Wenjie

    2017-08-01

    Recommender systems are used to accurately and actively provide users with potentially interesting information or services. Collaborative filtering is a widely adopted approach to recommendation, but sparse data and cold-start users are often barriers to providing high quality recommendations. To address such issues, we propose a novel method that works to improve the performance of collaborative filtering recommendations by integrating sparse rating data given by users and sparse social trust network among these same users. This is a model-based method that adopts matrix factorization technique that maps users into low-dimensional latent feature spaces in terms of their trust relationship, and aims to more accurately reflect the users reciprocal influence on the formation of their own opinions and to learn better preferential patterns of users for high-quality recommendations. We use four large-scale datasets to show that the proposed method performs much better, especially for cold start users, than state-of-the-art recommendation algorithms for social collaborative filtering based on trust.

  1. ADVANCED HOT GAS FILTER DEVELOPMENT

    Energy Technology Data Exchange (ETDEWEB)

    E.S. Connolly; G.D. Forsythe

    1998-12-22

    Advanced, coal-based power plants will require durable and reliable hot gas filtration systems to remove particulate contaminants from the gas streams to protect downstream components such as turbine blades from erosion damage. It is expected that the filter elements in these systems will have to be made of ceramic materials to withstand goal service temperatures of 1600 F or higher. Recent demonstration projects and pilot plant tests have indicated that the current generation of ceramic hot gas filters (cross-flow and candle configurations) are failing prematurely. Two of the most promising materials that have been extensively evaluated are clay-bonded silicon carbide and alumina-mullite porous monoliths. These candidates, however, have been found to suffer progressive thermal shock fatigue damage, as a result of rapid cooling/heating cycles. Such temperature changes occur when the hot filters are back-pulsed with cooler gas to clean them, or in process upset conditions, where even larger gas temperature changes may occur quickly and unpredictably. In addition, the clay-bonded silicon carbide materials are susceptible to chemical attack of the glassy binder phase that holds the SiC particles together, resulting in softening, strength loss, creep, and eventual failure.

  2. Switchable microwave photonic filter between high Q bandpass filter and notch filter with flat passband based on phase modulation.

    Science.gov (United States)

    Yu, Yuan; Xu, Enming; Dong, Jianji; Zhou, Lina; Li, Xiang; Zhang, Xinliang

    2010-11-22

    We propose and demonstrate a novel switchable microwave photonic filter based on phase modulation. Both a microwave high Q bandpass filter and a microwave notch filter with flat passband are achieved respectively. And the switchability between them by tuning the two tunable optical bandpass filters is demonstrated. We also present a theoretical model and analytical expression for the proposed scheme. A frequency response of a high Q bandpass filter with a Q factor of 327 and a rejection ratio of exceeding 42 dB, and a frequency response of a notch filter with flat passband with a rejection ratio exceeding 34 dB are experimentally obtained. The operation frequency of microwave photonic filter is around 20 GHz.

  3. HEPA Filter Use at the Hanford Site

    International Nuclear Information System (INIS)

    Kriskovich, J. R.

    2002-01-01

    High Efficiency Particulate Air (HEPA) filters are relied upon at the Hanford site to support several different activities. Each facility relies upon the filters to provide the same function; remove radioactive particulate from various air streams. However, HEPA filters are operated in differing environmental conditions from one facility to another and the constituents in the air streams also differ. In addition, some HEPA filters at the Hanford site have been in service for several years. As a result, an assessment was performed which evaluated the service life and conditions of the HEPA filters at the Hanford site

  4. HEPA Filter Use at the Hanford Site

    International Nuclear Information System (INIS)

    KRISKOVICH, J.R.

    2002-01-01

    High Efficiency Particulate Air (HEPA) filters are relied upon at the Hanford site to support several different activities. Each facility relies upon the filters to provide the same function, remove radioactive particulate However, HEPA filters are operated in differing environmental conditions from one facility to another and the constituents in the air streams also differ. In addition, some HEPA filters at the Hanford site have been in service for several years. As a result, an assessment was performed which evaluated the service life and conditions of the HEPA filters at the Hanford site

  5. Modeling and Measurements of Novel Monolithic Filters

    Directory of Open Access Journals (Sweden)

    Adalbert Beyer

    2008-11-01

    Full Text Available This paper presents novel multilayer tuneable high Q-filters based on hairpin resonators including ferroelectric materials. This configuration allows the miniaturization of these filters to a size that makes them suitable for chip and package integration and narrow-band applications. The main focus was miniaturizing filters with coupled loops using multilayer dielectric substrates. A further goal was to increase the quality factor of these distributed filters by embedding high dielectric materials in a multilayer high- and low-k (dielectric constant substrate that is supported by LTCC technology. An improved W-shape bandpass filter was proposed with a wide stopband and approximately 5% bandwidth.

  6. Tunable electro-optic filter stack

    Energy Technology Data Exchange (ETDEWEB)

    Fontecchio, Adam K.; Shriyan, Sameet K.; Bellingham, Alyssa

    2017-09-05

    A holographic polymer dispersed liquid crystal (HPDLC) tunable filter exhibits switching times of no more than 20 microseconds. The HPDLC tunable filter can be utilized in a variety of applications. An HPDLC tunable filter stack can be utilized in a hyperspectral imaging system capable of spectrally multiplexing hyperspectral imaging data acquired while the hyperspectral imaging system is airborne. HPDLC tunable filter stacks can be utilized in high speed switchable optical shielding systems, for example as a coating for a visor or an aircraft canopy. These HPDLC tunable filter stacks can be fabricated using a spin coating apparatus and associated fabrication methods.

  7. Adaptable Iterative and Recursive Kalman Filter Schemes

    Science.gov (United States)

    Zanetti, Renato

    2014-01-01

    Nonlinear filters are often very computationally expensive and usually not suitable for real-time applications. Real-time navigation algorithms are typically based on linear estimators, such as the extended Kalman filter (EKF) and, to a much lesser extent, the unscented Kalman filter. The Iterated Kalman filter (IKF) and the Recursive Update Filter (RUF) are two algorithms that reduce the consequences of the linearization assumption of the EKF by performing N updates for each new measurement, where N is the number of recursions, a tuning parameter. This paper introduces an adaptable RUF algorithm to calculate N on the go, a similar technique can be used for the IKF as well.

  8. Linear Regression Based Real-Time Filtering

    Directory of Open Access Journals (Sweden)

    Misel Batmend

    2013-01-01

    Full Text Available This paper introduces real time filtering method based on linear least squares fitted line. Method can be used in case that a filtered signal is linear. This constraint narrows a band of potential applications. Advantage over Kalman filter is that it is computationally less expensive. The paper further deals with application of introduced method on filtering data used to evaluate a position of engraved material with respect to engraving machine. The filter was implemented to the CNC engraving machine control system. Experiments showing its performance are included.

  9. Acoustic Wave Filter Technology-A Review.

    Science.gov (United States)

    Ruppel, Clemens C W

    2017-09-01

    Today, acoustic filters are the filter technology to meet the requirements with respect to performance dictated by the cellular phone standards and their form factor. Around two billion cellular phones are sold every year, and smart phones are of a very high percentage of approximately two-thirds. Smart phones require a very high number of filter functions ranging from the low double-digit range up to almost triple digit numbers in the near future. In the frequency range up to 1 GHz, surface acoustic wave (SAW) filters are almost exclusively employed, while in the higher frequency range, bulk acoustic wave (BAW) and SAW filters are competing for their shares. Prerequisites for the success of acoustic filters were the availability of high-quality substrates, advanced and highly reproducible fabrication technologies, optimum filter techniques, precise simulation software, and advanced design tools that allow the fast and efficient design according to customer specifications. This paper will try to focus on innovations leading to high volume applications of intermediate frequency (IF) and radio frequency (RF) acoustic filters, e.g., TV IF filters, IF filters for cellular phones, and SAW/BAW RF filters for the RF front-end of cellular phones.

  10. Electronic filters, hearing aids and methods

    Science.gov (United States)

    Engebretson, A. Maynard (Inventor); O'Connell, Michael P. (Inventor); Zheng, Baohua (Inventor)

    1991-01-01

    An electronic filter for an electroacoustic system. The system has a microphone for generating an electrical output from external sounds and an electrically driven transducer for emitting sound. Some of the sound emitted by the transducer returns to the microphone means to add a feedback contribution to its electical output. The electronic filter includes a first circuit for electronic processing of the electrical output of the microphone to produce a filtered signal. An adaptive filter, interconnected with the first circuit, performs electronic processing of the filtered signal to produce an adaptive output to the first circuit to substantially offset the feedback contribution in the electrical output of the microphone, and the adaptive filter includes means for adapting only in response to polarities of signals supplied to and from the first circuit. Other electronic filters for hearing aids, public address systems and other electroacoustic systems, as well as such systems, and methods of operating them are also disclosed.

  11. Filter device for radioactive gaseous wastes

    International Nuclear Information System (INIS)

    Hirano, Mikio; Suzuki, Masahiro.

    1983-01-01

    Purpose : To prevent captured particles from falling upon filter replacement by changing the positions for the gas inlet and outlet from those in the conventional device. Constitution : The filter device comprises a tightly closed vertical cylindrical vessel with an end plate and high efficiency granular filters (HEPA). Inlet and outlet nozzles are disposed at the upper and lower parts of the closed vessel on both sides of the HEPA filter. Radio-active gases are passed from above to below the HEPA filter and discharged from the outlet. In such a structure, captured particles are accumulated on the surface of the HEPA filter and do not fall even upon replacement of the HEPA filter. (Kawakami, Y.)

  12. Filter for isotopic alteration of mercury vapor

    Science.gov (United States)

    Grossman, Mark W.; George, William A.

    1989-01-01

    A filter for enriching the .sup.196 Hg content of mercury, including a reactor, a low pressure electric discharge lamp containing a fill of mercury and an inert gas. A filter is arranged concentrically around the lamp. The reactor is arranged around said filter, whereby radiation from said lamp passes through the filter and into said reactor. The lamp, the filter and the reactor are formed of quartz, and are transparent to ultraviolet light. The .sup.196 Hg concentration in the mercury fill is less than that which is present in naturally occurring mercury, that is less than about 0.146 atomic weight percent. Hydrogen is also included in the fill and serves as a quenching gas in the filter, the hydrogen also serving to prevent disposition of a dark coating on the interior of the filter.

  13. Image Filtering with Field Programmable Gate Array

    Directory of Open Access Journals (Sweden)

    Arūnas Šlenderis

    2013-05-01

    Full Text Available The research examined the use of field programmable gate arrays (FPGA in image filtering. Experimental and theoretical researches were reviewed. Experiments with Cyclone III family FPGA chip with implemented NIOS II soft processor were considered. Image filtering was achieved with symmetrical and asymmetrical finite impulse response filters with convolution kernel. The system, which was implemented with 3×3 symmetrical filter, which was implemented using the hardware description language, uses 59% of logic elements of the chip and 10 multiplication elements. The system with asymmetrical filter uses the same amount of logic elements and 13 multiplication elements. Both filter systems consume approx. 545 mW of power. The system, which is designed for filter implementation in C language, uses 65% of all logical elements and consumes 729 mW of power.Article in Lithuanian

  14. Analog Electronic Filters Theory, Design and Synthesis

    CERN Document Server

    Dimopoulos, Hercules G

    2012-01-01

    Filters are essential subsystems in a huge variety of electronic systems. Filter applications are innumerable; they are used for noise reduction, demodulation, signal detection, multiplexing, sampling, sound and speech processing, transmission line equalization and image processing, to name just a few. In practice, no electronic system can exist without filters. They can be found in everything from power supplies to mobile phones and hard disk drives and from loudspeakers and MP3 players to home cinema systems and broadband Internet connections. This textbook introduces basic concepts and methods and the associated mathematical and computational tools employed in electronic filter theory, synthesis and design.  This book can be used as an integral part of undergraduate courses on analog electronic filters. Includes numerous, solved examples, applied examples and exercises for each chapter. Includes detailed coverage of active and passive filters in an independent but correlated manner. Emphasizes real filter...

  15. Performance analysis and design of filtering hydrocyclones

    Directory of Open Access Journals (Sweden)

    L. G. M. Vieira

    2005-03-01

    Full Text Available The filtering hydrocyclone is a solid-liquid separation device patented by the Chemical Engineering Department at the Federal University of Uberlândia, which consists of a hydrocyclone whose conical section was replaced by a conical filtering wall. The objective of this work is to compare the performances of the filtering hydrocyclones designed by Bradley and by Rietema. The experimental results obtained with the filtering hydrocyclones under the same operational conditions as those used with the conventional device allow the conclusion that performance of the Bradley and Rietema types is significantly influenced by the filtering medium. Rietema's filtering hydrocyclones had a lower volumetric feed flowrate than the conventional device and Bradley's filtering hydrocyclones showed increases in this same variable. In both designs, overall efficiency was influenced by the underflow-to-throughput ratio.

  16. Signal enhancement with variable span linear filters

    CERN Document Server

    Benesty, Jacob; Jensen, Jesper R

    2016-01-01

    This book introduces readers to the novel concept of variable span speech enhancement filters, and demonstrates how it can be used for effective noise reduction in various ways. Further, the book provides the accompanying Matlab code, allowing readers to easily implement the main ideas discussed. Variable span filters combine the ideas of optimal linear filters with those of subspace methods, as they involve the joint diagonalization of the correlation matrices of the desired signal and the noise. The book shows how some well-known filter designs, e.g. the minimum distortion, maximum signal-to-noise ratio, Wiener, and tradeoff filters (including their new generalizations) can be obtained using the variable span filter framework. It then illustrates how the variable span filters can be applied in various contexts, namely in single-channel STFT-based enhancement, in multichannel enhancement in both the time and STFT domains, and, lastly, in time-domain binaural enhancement. In these contexts, the properties of ...

  17. UV filters for lighting of plants

    Energy Technology Data Exchange (ETDEWEB)

    Doehring, T.; Koefferlein, M.; Thiel, S.; Seidlitz, H.K.; Payer, H.D. [GSF-Forschungszentrum fuer Umwelt und Gesundheit GmbH, Oberschleissheim (Germany)

    1994-12-31

    Different filter glasses are available which provide absorption properties suitable for gradual changes of the spectral UV-B illumination of artificial lighting. Using a distinct set of lamps and filter glasses an acceptable simulation of the UV-B part of natural global radiation can be achieved. The ageing of these and other filter materials under the extreme UV radiation in the lamphouse of a solar simulator is presently unavoidable. This instability can be dealt with only by a precise spectral monitoring and by replacing the filters accordingly. For this reason attempts would be useful to develop real ozone filters which can replace glass filters. In any case chamber experiments require a careful selection of the filter material used and must be accompanied by a continuous UV-B monitoring.

  18. Merging particle filter for sequential data assimilation

    Directory of Open Access Journals (Sweden)

    S. Nakano

    2007-07-01

    Full Text Available A new filtering technique for sequential data assimilation, the merging particle filter (MPF, is proposed. The MPF is devised to avoid the degeneration problem, which is inevitable in the particle filter (PF, without prohibitive computational cost. In addition, it is applicable to cases in which a nonlinear relationship exists between a state and observed data where the application of the ensemble Kalman filter (EnKF is not effectual. In the MPF, the filtering procedure is performed based on sampling of a forecast ensemble as in the PF. However, unlike the PF, each member of a filtered ensemble is generated by merging multiple samples from the forecast ensemble such that the mean and covariance of the filtered distribution are approximately preserved. This merging of multiple samples allows the degeneration problem to be avoided. In the present study, the newly proposed MPF technique is introduced, and its performance is demonstrated experimentally.

  19. Evaluation of HEPA filter service life

    International Nuclear Information System (INIS)

    Fretthold, J.K.; Stithem, A.R.

    1997-01-01

    Rocky Flats Environmental Technology Site (RFETS), has approximately 10,000 High Efficiency Particulate Air (HEPA) Filters installed in a variety of filter plenums. These ventilation/filtration plenum systems are used to control the release of airborne particulate contaminates to the environment during normal operations and potential accidents. This report summarizes the results of destructive and non-destructive tests on HEPA filters obtained from a wide variety of ages and service conditions. These tests were performed to determine an acceptable service life criteria for HEPA filters used at Rocky Flats Environmental Technology Site (RFETS). A total of 140 filters of various ages (1972 to 1996) and service history (new, aged unused, used) were tested. For the purpose of this report, filter age from manufacture date/initial test date to the current sample date was used, as opposed to the actual time a filter was installed in an operating system

  20. Signal Enhancement with Variable Span Linear Filters

    DEFF Research Database (Denmark)

    Benesty, Jacob; Christensen, Mads Græsbøll; Jensen, Jesper Rindom

    This book introduces readers to the novel concept of variable span speech enhancement filters, and demonstrates how it can be used for effective noise reduction in various ways. Further, the book provides the accompanying Matlab code, allowing readers to easily implement the main ideas discussed....... Variable span filters combine the ideas of optimal linear filters with those of subspace methods, as they involve the joint diagonalization of the correlation matrices of the desired signal and the noise. The book shows how some well-known filter designs, e.g. the minimum distortion, maximum signal......-to-noise ratio, Wiener, and tradeoff filters (including their new generalizations) can be obtained using the variable span filter framework. It then illustrates how the variable span filters can be applied in various contexts, namely in single-channel STFT-based enhancement, in multichannel enhancement in both...