WorldWideScience

Sample records for single valued function

  1. Uniform Single Valued Neutrosophic Graphs

    Directory of Open Access Journals (Sweden)

    S. Broumi

    2017-09-01

    Full Text Available In this paper, we propose a new concept named the uniform single valued neutrosophic graph. An illustrative example and some properties are examined. Next, we develop an algorithmic approach for computing the complement of the single valued neutrosophic graph. A numerical example is demonstrated for computing the complement of single valued neutrosophic graphs and uniform single valued neutrosophic graph.

  2. Regular Single Valued Neutrosophic Hypergraphs

    Directory of Open Access Journals (Sweden)

    Muhammad Aslam Malik

    2016-12-01

    Full Text Available In this paper, we define the regular and totally regular single valued neutrosophic hypergraphs, and discuss the order and size along with properties of regular and totally regular single valued neutrosophic hypergraphs. We also extend work on completeness of single valued neutrosophic hypergraphs.

  3. ON BIPOLAR SINGLE VALUED NEUTROSOPHIC GRAPHS

    OpenAIRE

    Said Broumi; Mohamed Talea; Assia Bakali; Florentin Smarandache

    2016-01-01

    In this article, we combine the concept of bipolar neutrosophic set and graph theory. We introduce the notions of bipolar single valued neutrosophic graphs, strong bipolar single valued neutrosophic graphs, complete bipolar single valued neutrosophic graphs, regular bipolar single valued neutrosophic graphs and investigate some of their related properties.

  4. Single Value Devices

    NARCIS (Netherlands)

    Mader, Angelika H.; Dertien, Edwin Christian; Reidsma, Dennis

    2011-01-01

    We live in a world of continuous information overflow, but the quality of information and communication is suffering. Single value devices contribute to the information and communication quality by fo- cussing on one explicit, relevant piece of information. The information is decoupled from a

  5. On Single-Valued Neutrosophic Entropy of order α

    Directory of Open Access Journals (Sweden)

    Harish Garg, Nancy

    2016-12-01

    Full Text Available Entropy is one of the measures which is used for measuring the fuzziness of the set. In this article, we have presented an entropy measure of order α under the single-valued neutrosophic set environment by considering the pair of their membership functions as well as the hesitation degree between them. Based on this measure, some of its desirable properties have been proposed and validated by taking an example of structure linguistic variable.

  6. Combining p-values in replicated single-case experiments with multivariate outcome.

    Science.gov (United States)

    Solmi, Francesca; Onghena, Patrick

    2014-01-01

    Interest in combining probabilities has a long history in the global statistical community. The first steps in this direction were taken by Ronald Fisher, who introduced the idea of combining p-values of independent tests to provide a global decision rule when multiple aspects of a given problem were of interest. An interesting approach to this idea of combining p-values is the one based on permutation theory. The methods belonging to this particular approach exploit the permutation distributions of the tests to be combined, and use a simple function to combine probabilities. Combining p-values finds a very interesting application in the analysis of replicated single-case experiments. In this field the focus, while comparing different treatments effects, is more articulated than when just looking at the means of the different populations. Moreover, it is often of interest to combine the results obtained on the single patients in order to get more global information about the phenomenon under study. This paper gives an overview of how the concept of combining p-values was conceived, and how it can be easily handled via permutation techniques. Finally, the method of combining p-values is applied to a simulated replicated single-case experiment, and a numerical illustration is presented.

  7. Recommended values of clean metal surface work functions

    International Nuclear Information System (INIS)

    Derry, Gregory N.; Kern, Megan E.; Worth, Eli H.

    2015-01-01

    A critical review of the experimental literature for measurements of the work functions of clean metal surfaces of single-crystals is presented. The tables presented include all results found for low-index crystal faces except cases that were known to be contaminated surfaces. These results are used to construct a recommended value of the work function for each surface examined, along with an uncertainty estimate for that value. The uncertainties are based in part on the error distribution for all measured work functions in the literature, which is included here. The metals included in this review are silver (Ag), aluminum (Al), gold (Au), copper (Cu), iron (Fe), iridium (Ir), molybdenum (Mo), niobium (Nb), nickel (Ni), palladium (Pd), platinum (Pt), rhodium (Rh), ruthenium (Ru), tantalum (Ta), and tungsten (W)

  8. Recommended values of clean metal surface work functions

    Energy Technology Data Exchange (ETDEWEB)

    Derry, Gregory N., E-mail: gderry@loyola.edu; Kern, Megan E.; Worth, Eli H. [Department of Physics, Loyola University Maryland, 4501 N. Charles St., Baltimore, Maryland 21210 (United States)

    2015-11-15

    A critical review of the experimental literature for measurements of the work functions of clean metal surfaces of single-crystals is presented. The tables presented include all results found for low-index crystal faces except cases that were known to be contaminated surfaces. These results are used to construct a recommended value of the work function for each surface examined, along with an uncertainty estimate for that value. The uncertainties are based in part on the error distribution for all measured work functions in the literature, which is included here. The metals included in this review are silver (Ag), aluminum (Al), gold (Au), copper (Cu), iron (Fe), iridium (Ir), molybdenum (Mo), niobium (Nb), nickel (Ni), palladium (Pd), platinum (Pt), rhodium (Rh), ruthenium (Ru), tantalum (Ta), and tungsten (W)

  9. The triad value function

    DEFF Research Database (Denmark)

    Vedel, Mette

    2016-01-01

    the triad value function. Next, the applicability and validity of the concept is examined in a case study of four closed vertical supply chain triads. Findings - The case study demonstrates that the triad value function facilitates the analysis and understanding of an apparent paradox; that distributors...... are not dis-intermediated in spite of their limited contribution to activities in the triads. The results indicate practical adequacy of the triad value function. Research limitations/implications - The triad value function is difficult to apply in the study of expanded networks as the number of connections...... expands exponentially with the number of ties in the network. Moreover, it must be applied in the study of service triads and open vertical supply chain triads to further verify the practical adequacy of the concept. Practical implications - The triad value function cannot be used normatively...

  10. Do single women value early retirement more than single men?

    DEFF Research Database (Denmark)

    Danø, Anne Møller; Ejrnæs, Mette; Husted, Leif

    2005-01-01

    and health are important determinants of the retirement decision. Furthermore, we find substantial gender differences in the retirement pattern. Healthy single women value retirement more than healthy single men and are willing to reduce their disposable income to 74% of their previous income while men......The focus of this paper is to analyse why a large fraction of single elderly people choose to retire early. A structural model directly based on the individual decision of labour supply is estimated on a sample of singles, where singles are defined as those who are living alone. We find that income...... are willing to reduce the income to 81%. Men's retirement decision is mainly influenced by income and health, whereas women's retirement decision is also affected by education and unemployment experience...

  11. Value function in economic growth model

    Science.gov (United States)

    Bagno, Alexander; Tarasyev, Alexandr A.; Tarasyev, Alexander M.

    2017-11-01

    Properties of the value function are examined in an infinite horizon optimal control problem with an unlimited integrand index appearing in the quality functional with a discount factor. Optimal control problems of such type describe solutions in models of economic growth. Necessary and sufficient conditions are derived to ensure that the value function satisfies the infinitesimal stability properties. It is proved that value function coincides with the minimax solution of the Hamilton-Jacobi equation. Description of the growth asymptotic behavior for the value function is provided for the logarithmic, power and exponential quality functionals and an example is given to illustrate construction of the value function in economic growth models.

  12. Effect of single-particle splitting in the exact wave function of the isovectorial pairing Hamiltonian

    International Nuclear Information System (INIS)

    Lerma H, S.

    2010-01-01

    The structure of the exact wave function of the isovectorial pairing Hamiltonian with nondegenerate single-particle levels is discussed. The way that the single-particle splittings break the quartet condensate solution found for N=Z nuclei in a single degenerate level is established. After a brief review of the exact solution, the structure of the wave function is analyzed and some particular cases are considered where a clear interpretation of the wave function emerges. An expression for the exact wave function in terms of the isospin triplet of pair creators is given. The ground-state wave function is analyzed as a function of pairing strength, for a system of four protons and four neutrons. For small and large values of the pairing strength a dominance of two-pair (quartets) scalar couplings is found, whereas for intermediate values enhancements of the nonscalar couplings are obtained. A correlation of these enhancements with the creation of Cooper-like pairs is observed.

  13. Cultural Values in Intergroup and Single-Group Social Dilemmas.

    Science.gov (United States)

    Probst; Carnevale; Triandis

    1999-03-01

    Do cultural values influence the manner in which people cooperate with one another? This study assessed cultural characteristics of individuals and then related these characteristics to cooperative behavior in social dilemmas. Participants were assessed for their degree of vertical and horizontal individualism and collectivism, cultural values identified by Triandis (1995). They made choices in either a single-group or an intergroup social dilemma. The single-group dilemma entailed a three-person dilemma; the intergroup dilemma was identical but added subgroup competition, i.e., an opposing three-person group. The results indicated an interaction between cultural characteristics and type of dilemma for cooperation. The single-group versus intergroup effect reported by Bornstein and Ben-Yossef (1994) was replicated, but only for vertical individualists. The vertical individualists were least cooperative in the single-group dilemma but were more cooperative in the intergroup dilemma-where cooperation with the group maximized personal outcomes. The vertical collectivists were most cooperative in the single-group dilemma but were less cooperative in the intergroup dilemma- where group defection resulted in maximum group outcomes. The horizontal individualists and collectivists exhibited an intermediate level of cooperation, with no differences in cooperation between the single-group and intergroup dilemmas. Taken together, the results suggest that the relationship between cultural values and cooperation, in particular with reference to vertical and horizontal components of individualism and collectivism, is more complex than has been suggested in past research. Copyright 1999 Academic Press.

  14. Convolution of Distribution-Valued Functions. Applications.

    OpenAIRE

    BARGETZ, CHRISTIAN

    2011-01-01

    In this article we examine products and convolutions of vector-valued functions. For nuclear normal spaces of distributions Proposition 25 in [31,p. 120] yields a vector-valued product or convolution if there is a continuous product or convolution mapping in the range of the vector-valued functions. For specific spaces, we generalize this result to hypocontinuous bilinear maps at the expense of generality with respect to the function space. We consider holomorphic, meromorphic and differentia...

  15. Density functional theory prediction of pKa for carboxylated single-wall carbon nanotubes and graphene

    Science.gov (United States)

    Li, Hao; Fu, Aiping; Xue, Xuyan; Guo, Fengna; Huai, Wenbo; Chu, Tianshu; Wang, Zonghua

    2017-06-01

    Density functional calculations have been performed to investigate the acidities for the carboxylated single-wall carbon nanotubes and graphene. The pKa values for different COOH-functionalized models with varying lengths, diameters and chirality of nanotubes and with different edges of graphene were predicted using the SMD/M05-2X/6-31G* method combined with two universal thermodynamic cycles. The effects of following factors, such as, the functionalized position of carboxyl group, the Stone-Wales and single vacancy defects, on the acidity of the functionalized nanotube and graphene have also been evaluated. The deprotonated species have undergone decarboxylation when the hybridization mode of the carbon atom at the functionalization site changed from sp2 to sp3 both for the tube and graphene. The knowledge of the pKa values of the carboxylated nanotube and graphene could be of great help for the understanding of the nanocarbon materials in many diverse areas, including environmental protection, catalysis, electrochemistry and biochemistry.

  16. Improving functional value of meat products.

    Science.gov (United States)

    Zhang, Wangang; Xiao, Shan; Samaraweera, Himali; Lee, Eun Joo; Ahn, Dong U

    2010-09-01

    In recent years, much attention has been paid to develop meat and meat products with physiological functions to promote health conditions and prevent the risk of diseases. This review focuses on strategies to improve the functional value of meat and meat products. Value improvement can be realized by adding functional compounds including conjugated linoneleic acid, vitamin E, n3 fatty acids and selenium in animal diets to improve animal production, carcass composition and fresh meat quality. In addition, functional ingredients such as vegetable proteins, dietary fibers, herbs and spices, and lactic acid bacteria can be directly incorporated into meat products during processing to improve their functional value for consumers. Functional compounds, especially peptides, can also be generated from meat and meat products during processing such as fermentation, curing and aging, and enzymatic hydrolysis. This review further discusses the current status, consumer acceptance, and market for functional foods from the global viewpoints. Future prospects for functional meat and meat products are also discussed.

  17. Variance Function Partially Linear Single-Index Models1.

    Science.gov (United States)

    Lian, Heng; Liang, Hua; Carroll, Raymond J

    2015-01-01

    We consider heteroscedastic regression models where the mean function is a partially linear single index model and the variance function depends upon a generalized partially linear single index model. We do not insist that the variance function depend only upon the mean function, as happens in the classical generalized partially linear single index model. We develop efficient and practical estimation methods for the variance function and for the mean function. Asymptotic theory for the parametric and nonparametric parts of the model is developed. Simulations illustrate the results. An empirical example involving ozone levels is used to further illustrate the results, and is shown to be a case where the variance function does not depend upon the mean function.

  18. Representations of Multiple-Valued Logic Functions

    CERN Document Server

    Stankovic, Radomir S

    2012-01-01

    Compared to binary switching functions, multiple-valued functions offer more compact representations of the information content of signals modeled by logic functions and, therefore, their use fits very well in the general settings of data compression attempts and approaches. The first task in dealing with such signals is to provide mathematical methods for their representation in a way that will make their application in practice feasible.Representation of Multiple-Valued Logic Functions is aimed at providing an accessible introduction to these mathematical techniques that are necessary for ap

  19. 21 CFR 870.1435 - Single-function, preprogrammed diagnostic computer.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Single-function, preprogrammed diagnostic computer... Single-function, preprogrammed diagnostic computer. (a) Identification. A single-function, preprogrammed diagnostic computer is a hard-wired computer that calculates a specific physiological or blood-flow parameter...

  20. Acute single channel EEG predictors of cognitive function after stroke.

    Directory of Open Access Journals (Sweden)

    Anna Aminov

    Full Text Available Early and accurate identification of factors that predict post-stroke cognitive outcome is important to set realistic targets for rehabilitation and to guide patients and their families accordingly. However, behavioral measures of cognition are difficult to obtain in the acute phase of recovery due to clinical factors (e.g. fatigue and functional barriers (e.g. language deficits. The aim of the current study was to test whether single channel wireless EEG data obtained acutely following stroke could predict longer-term cognitive function.Resting state Relative Power (RP of delta, theta, alpha, beta, delta/alpha ratio (DAR, and delta/theta ratio (DTR were obtained from a single electrode over FP1 in 24 participants within 72 hours of a first-ever stroke. The Montreal Cognitive Assessment (MoCA was administered at 90-days post-stroke. Correlation and regression analyses were completed to identify relationships between 90-day cognitive function and electrophysiological data, neurological status, and demographic characteristics at admission.Four acute qEEG indices demonstrated moderate to high correlations with 90-day MoCA scores: DTR (r = -0.57, p = 0.01, RP theta (r = 0.50, p = 0.01, RP delta (r = -0.47, p = 0.02, and DAR (r = -0.45, p = 0.03. Acute DTR (b = -0.36, p < 0.05 and stroke severity on admission (b = -0.63, p < 0.01 were the best linear combination of predictors of MoCA scores 90-days post-stroke, accounting for 75% of variance.Data generated by a single pre-frontal electrode support the prognostic value of acute DAR, and identify DTR as a potential marker of post-stroke cognitive outcome. Use of single channel recording in an acute clinical setting may provide an efficient and valid predictor of cognitive function after stroke.

  1. Semiclassical initial value approximation for Green's function.

    Science.gov (United States)

    Kay, Kenneth G

    2010-06-28

    A semiclassical initial value approximation is obtained for the energy-dependent Green's function. For a system with f degrees of freedom the Green's function expression has the form of a (2f-1)-dimensional integral over points on the energy surface and an integral over time along classical trajectories initiated from these points. This approximation is derived by requiring an integral ansatz for Green's function to reduce to Gutzwiller's semiclassical formula when the integrations are performed by the stationary phase method. A simpler approximation is also derived involving only an (f-1)-dimensional integral over momentum variables on a Poincare surface and an integral over time. The relationship between the present expressions and an earlier initial value approximation for energy eigenfunctions is explored. Numerical tests for two-dimensional systems indicate that good accuracy can be obtained from the initial value Green's function for calculations of autocorrelation spectra and time-independent wave functions. The relative advantages of initial value approximations for the energy-dependent Green's function and the time-dependent propagator are discussed.

  2. On Approximation of Hyper-geometric Function Values of a Special Class

    Directory of Open Access Journals (Sweden)

    P. L. Ivankov

    2017-01-01

    Full Text Available Investigations of arithmetic properties of the hyper-geometric function values make it possible to single out two trends, namely, Siegel’s method and methods based on the effective construction of a linear approximating form. There are also methods combining both approaches mentioned.  The Siegel’s method allows obtaining the most general results concerning the abovementioned problems. In many cases it was used to establish the algebraic independence of the values of corresponding functions. Although the effective methods do not allow obtaining propositions of such generality they have nevertheless some advantages. Among these advantages one can distinguish at least two: a higher precision of the quantitative results obtained by effective methods and a possibility to study the hyper-geometric functions with irrational parameters.In this paper we apply the effective construction to estimate a measure of the linear independence of the hyper-geometric function values over the imaginary quadratic field. The functions themselves were chosen by a special way so that it could be possible to demonstrate a new approach to the effective construction of a linear approximating form. This approach makes it possible also to extend the well-known effective construction methods of the linear approximating forms for poly-logarithms to the functions of more general type.To obtain the arithmetic result we had to establish a linear independence of the functions under consideration over the field of rational functions. It is apparently impossible to apply directly known theorems containing sufficient (and in some cases needful and sufficient conditions for the system of functions appearing in the theorems mentioned. For this reason, a special technique has been developed to solve this problem.The paper presents the obtained arithmetic results concerning the values of integral functions, but, with appropriate alterations, the theorems proved can be adapted to

  3. A Single Conjunction Risk Assessment Metric: the F-Value

    Science.gov (United States)

    Frigm, Ryan Clayton; Newman, Lauri K.

    2009-01-01

    The Conjunction Assessment Team at NASA Goddard Space Flight Center provides conjunction risk assessment for many NASA robotic missions. These risk assessments are based on several figures of merit, such as miss distance, probability of collision, and orbit determination solution quality. However, these individual metrics do not singly capture the overall risk associated with a conjunction, making it difficult for someone without this complete understanding to take action, such as an avoidance maneuver. The goal of this analysis is to introduce a single risk index metric that can easily convey the level of risk without all of the technical details. The proposed index is called the conjunction "F-value." This paper presents the concept of the F-value and the tuning of the metric for use in routine Conjunction Assessment operations.

  4. Functional Upgrading and Value Capture of Multinational Subsidiaries

    DEFF Research Database (Denmark)

    Burger, Anže; Jindra, Björn; Marek, Philipp

    2018-01-01

    survey-based business function indicators with longitudinal accounting data for a representative sample of multinational subsidiaries located in six Central and Eastern European countries (CEECs), we assess the impact of functional upgrading on foreign subsidiaries' value capture. The results provide......This paper investigates the relationship between the value capture of multinational subsidiaries and functional upgrading, which is defined as a diversification of employment from primary business functions to higher value adding activities such as ICT, R&D, marketing or logistics. By combining...... robust evidence that the breadth as well as the scope of functional upgrading induces an upward shift of subsidiaries' value added. The effect of functional upgrading is stronger in the earlier phases after entry of the foreign investor, while the long-term growth trend remains unaffected....

  5. Normal thyroid function values in Ethiopians

    International Nuclear Information System (INIS)

    Wassie, Emnetu; Abdulkadir, Jemal

    1990-01-01

    Thyroid function values were determined in 56 healthy nongoitrous adult Ethiopians. The mean triiodothyronine (T3) values for 20 males and 36 females were 1.42+-0.32 nmol/L and 1.51+-0.25 nmol/L, and thyroxine (T4) values were 119 22 nmol/L and 116+21 nmol/L respectively. The mean thyrotropin (TSH) values for males and females were identical at 1.86+-0.94 mu/L. Radioactive iodine uptake (RAIU) at 2 hours was 8.6+-4.4% in males and 11.3+-4.3% in females, and at 24 hours 31.7+-11.7% and 38.9+-11.1% respectively. The difference between males and females were significant at both 2 and 24 hours (P<0.05). The ranges for the 3 hormones derived from the mean 2SD values are close to these supplied with the kits but the Ethiopian RAIU values are higher than the values currently applicable in developed countries, probably indicative of the lower level of dietary iodine available to the population here. The values obtained in this study are offered to serve as normal reference for the interpretation of thyroid function results in Ethiopian patients. A strategy for the rational utilization of the available in vitro tests is suggested

  6. On single nucleon wave functions in nuclei

    International Nuclear Information System (INIS)

    Talmi, Igal

    2011-01-01

    The strong and singular interaction between nucleons, makes the nuclear many body theory very complicated. Still, nuclei exhibit simple and regular features which are simply described by the shell model. Wave functions of individual nucleons may be considered just as model wave functions which bear little resemblance to the real ones. There is, however, experimental evidence for the reality of single nucleon wave functions. There is a simple method of constructing such wave functions for valence nucleons. It is shown that this method can be improved by considering the polarization of the core by the valence nucleon. This gives rise to some rearrangement energy which affects the single valence nucleon energy within the nucleus.

  7. 21 CFR 868.1890 - Predictive pulmonary-function value calculator.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Predictive pulmonary-function value calculator... SERVICES (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1890 Predictive pulmonary-function value calculator. (a) Identification. A predictive pulmonary-function value calculator is...

  8. The position value for partition function form network games

    NARCIS (Netherlands)

    Nouweland, van den C.G.A.M.; Slikker, M.

    We use the axiomatization of the position value for network situations in van den Nouweland and Slikker (2012) to define a position value for partition function form network situations. We do this by generalizing the axioms to the partition function form value function setting as studied in Navarro

  9. Tunable complex-valued multi-tap microwave photonic filter based on single silicon-on-insulator microring resonator.

    Science.gov (United States)

    Lloret, Juan; Sancho, Juan; Pu, Minhao; Gasulla, Ivana; Yvind, Kresten; Sales, Salvador; Capmany, José

    2011-06-20

    A complex-valued multi-tap tunable microwave photonic filter based on single silicon-on-insulator microring resonator is presented. The degree of tunability of the approach involving two, three and four taps is theoretical and experimentally characterized, respectively. The constraints of exploiting the optical phase transfer function of a microring resonator aiming at implementing complex-valued multi-tap filtering schemes are also reported. The trade-off between the degree of tunability without changing the free spectral range and the number of taps is studied in-depth. Different window based scenarios are evaluated for improving the filter performance in terms of the side-lobe level.

  10. Long-Term and Short-Term Effects of Hemodialysis on Liver Function Evaluated Using the Galactose Single-Point Test

    Directory of Open Access Journals (Sweden)

    Yi-Chou Hou

    2014-01-01

    Full Text Available Aim. The galactose single-point (GSP test assesses functioning liver mass by measuring the galactose concentration in the blood 1 hour after its administration. The purpose of this study was to investigate the impact of hemodialysis (HD on short-term and long-term liver function by use of GSP test. Methods. Seventy-four patients on maintenance HD (46 males and 28 females, 60.38 ± 11.86 years with a mean time on HD of 60.77 ± 48.31 months were studied. The GSP values were compared in two groups: (1 before and after single session HD, and (2 after one year of maintenance HD. Results. Among the 74 HD patient, only the post-HD Cr levels and years on dialysis were significantly correlated with GSP values (r=0.280, P<0.05 and r=-0.240, P<0.05, resp.. 14 of 74 patients were selected for GSP evaluation before and after a single HD session, and the hepatic clearance of galactose was similar (pre-HD 410 ± 254 g/mL, post-HD 439 ± 298 g/mL, P=0.49. GSP values decreased from 420.20 ± 175.26 g/mL to 383.40 ± 153.97 g/mL after 1 year maintenance HD in other 15 patients (mean difference: 19.00 ± 37.66 g/mL, P<0.05. Conclusions. Patients on maintenance HD for several years may experience improvement of their liver function. However, a single HD session does not affect liver function significantly as assessed by the GSP test. Since the metabolism of galactose is dependent on liver blood flow and hepatic functional mass, further studies are needed.

  11. Hierarchical structure of correlation functions for single jets

    International Nuclear Information System (INIS)

    Lupia, S.; Giovannini, A.; Ugoccioni, R.

    1993-01-01

    Theoretical basis of void scaling function properties of hierarchical structure in rapidity and p T intervals are explored. Their phenomenological consequences are analyzed at single jet level by using Monte Carlo methods in e + e - annihilation. It is found that void scaling function study provides an interesting alternative approach for characterizing single jets of different origin. (orig.)

  12. Study of clean and ion bombardment damaged silver single crystal surfaces by work function measurements

    International Nuclear Information System (INIS)

    Chelvayohan, N.

    1982-06-01

    Work function values of the (110), (100) and (111) faces of silver single crystal were measured by the photoelectric emission method and found to be 4.14 +- 0.04 eV, 4.22 +-0.04 eV and 4.46 +- 0.02 eV respectively. Oxygen adsorption on the faces were studied by surface potential measurement. Strong oxygen adsorption was observed on (110) and (100) faces, whereas the (111) face was found to be inert for oxygen adsorption. Oxygen adsorption on the (111) face damaged by argon ion bombardment was also investigated. The above results were compared with those of early reported work function and oxygen adsorption values. (U.K.)

  13. TODIM Method for Single-Valued Neutrosophic Multiple Attribute Decision Making

    Directory of Open Access Journals (Sweden)

    Dong-Sheng Xu

    2017-10-01

    Full Text Available Recently, the TODIM has been used to solve multiple attribute decision making (MADM problems. The single-valued neutrosophic sets (SVNSs are useful tools to depict the uncertainty of the MADM. In this paper, we will extend the TODIM method to the MADM with the single-valued neutrosophic numbers (SVNNs. Firstly, the definition, comparison, and distance of SVNNs are briefly presented, and the steps of the classical TODIM method for MADM problems are introduced. Then, the extended classical TODIM method is proposed to deal with MADM problems with the SVNNs, and its significant characteristic is that it can fully consider the decision makers’ bounded rationality which is a real action in decision making. Furthermore, we extend the proposed model to interval neutrosophic sets (INSs. Finally, a numerical example is proposed.

  14. Hierarchical structure of correlation functions for single jets

    Energy Technology Data Exchange (ETDEWEB)

    Lupia, S. (Dipt. di Fisica Teorica, Univ. di Torino, and INFN, Sezione di Torino (Italy)); Giovannini, A. (Dipt. di Fisica Teorica, Univ. di Torino, and INFN, Sezione di Torino (Italy)); Ugoccioni, R. (Dipt. di Fisica Teorica, Univ. di Torino, and INFN, Sezione di Torino (Italy))

    1993-08-01

    Theoretical basis of void scaling function properties of hierarchical structure in rapidity and p[sub T] intervals are explored. Their phenomenological consequences are analyzed at single jet level by using Monte Carlo methods in e[sup +]e[sup -] annihilation. It is found that void scaling function study provides an interesting alternative approach for characterizing single jets of different origin. (orig.)

  15. Models for Multiple Attribute Decision-Making with Dual Generalized Single-Valued Neutrosophic Bonferroni Mean Operators

    Directory of Open Access Journals (Sweden)

    Jie Wang

    2018-01-01

    Full Text Available In this article, we expand the dual generalized weighted BM (DGWBM and dual generalized weighted geometric Bonferroni mean (DGWGBM operator with single valued neutrosophic numbers (SVNNs to propose the dual generalized single-valued neutrosophic number WBM (DGSVNNWBM operator and dual generalized single-valued neutrosophic numbers WGBM (DGSVNNWGBM operator. Then, the multiple attribute decision making (MADM methods are proposed with these operators. In the end, we utilize an applicable example for strategic suppliers selection to prove the proposed methods.

  16. Integrals of operator-valued functions

    Directory of Open Access Journals (Sweden)

    Raimond A. Struble

    1988-01-01

    Full Text Available Mikusinski-type expansions of operator-valued functions are discussed in some detail. As a natural part of the development, a “kernel” concept for operators is proposed and an elaborate system of convolution quotients in one and two variables is obtained.

  17. Special values of the spectral zeta function of the non-commutative harmonic oscillator and confluent Heun equations

    CERN Document Server

    Ichinose, T

    2004-01-01

    We study the special values at $s=2$ and $3$ of the spectral zeta function $\\zeta_Q(s)$ of the non-commutative harmonic oscillator $Q(x,D_x)$ introduced in \\cite{PW1, 2}. It is shown that the series defining $\\zeta_Q(s)$ converges absolutely for Re $s>1$ and further the respective values $\\zeta_Q(2)$ and $\\zeta_Q(3)$ are represented essentially by contour integrals of the solutions, respectively, of a singly confluent Heun's ordinary differential equation and of exactly the same but an inhomogeneous equation. As a by-product of these results, we obtain integral representations of the solutions of these equations by rational functions. \\par\

  18. The functional value of Caribbean coral reef, seagrass and mangrove habitats to ecosystem processes.

    Science.gov (United States)

    Harborne, Alastair R; Mumby, Peter J; Micheli, Fiorenza; Perry, Christopher T; Dahlgren, Craig P; Holmes, Katherine E; Brumbaugh, Daniel R

    2006-01-01

    Caribbean coral reef habitats, seagrass beds and mangroves provide important goods and services both individually and through functional linkages. A range of anthropogenic factors are threatening the ecological and economic importance of these habitats and it is vital to understand how ecosystem processes vary across seascapes. A greater understanding of processes will facilitate further insight into the effects of disturbances and assist with assessing management options. Despite the need to study processes across whole seascapes, few spatially explicit ecosystem-scale assessments exist. We review the empirical literature to examine the role of different habitat types for a range of processes. The importance of each of 10 generic habitats to each process is defined as its "functional value" (none, low, medium or high), quantitatively derived from published data wherever possible and summarised in a single figure. This summary represents the first time the importance of habitats across an entire Caribbean seascape has been assessed for a range of processes. Furthermore, we review the susceptibility of each habitat to disturbances to investigate spatial patterns that might affect functional values. Habitat types are considered at the scale discriminated by remotely-sensed imagery and we envisage that functional values can be combined with habitat maps to provide spatially explicit information on processes across ecosystems. We provide examples of mapping the functional values of habitats for populations of three commercially important species. The resulting data layers were then used to generate seascape-scale assessments of "hot spots" of functional value that might be considered priorities for conservation. We also provide an example of how the literature reviewed here can be used to parameterise a habitat-specific model investigating reef resilience under different scenarios of herbivory. Finally, we use multidimensional scaling to provide a basic analysis of the

  19. Cost of product functions using analysis of value

    Directory of Open Access Journals (Sweden)

    Luminita Parv

    2016-09-01

    Full Text Available The value of use is a specific notion but of a great generality that makes the product be regarded as a complex system that transforms itself in time, thus undergoing evolution. Therefore, the product is important not in itself, but for the sake of the requirements it satisfies and for the functions it provides. In the analysis of value there are connections of a technical nature that implicitly lead to connections of an economic nature. Thus, the method of the ”analysis of value” will actually examine the cost of product functions, the aim of the method being the balance of functions costs on the basis of their importance for the product. Identifying the functions represents one of the important stages of the analysis of value. The difficulty in fixing the functions derives from the fact that there are not any rules clear enough for this activity, but only principles

  20. Single-particle properties from Kohn-Sham Green's functions

    International Nuclear Information System (INIS)

    Bhattacharyya, Anirban; Furnstahl, R.J.

    2005-01-01

    An effective action approach to Kohn-Sham density functional theory is used to illustrate how the exact Green's function can be calculated in terms of the Kohn-Sham Green's function. An example based on Skyrme energy functionals shows that single-particle Kohn-Sham spectra can be improved by adding sources used to construct the energy functional

  1. Capillary electrophoresis of covalently functionalized single-chirality carbon nanotubes.

    Science.gov (United States)

    He, Pingli; Meany, Brendan; Wang, Chunyan; Piao, Yanmei; Kwon, Hyejin; Deng, Shunliu; Wang, YuHuang

    2017-07-01

    We demonstrate the separation of chirality-enriched single-walled carbon nanotubes (SWCNTs) by degree of surface functionalization using high-performance CE. Controlled amounts of negatively charged and positively charged functional groups were attached to the sidewall of chirality-enriched SWCNTs through covalent functionalization using 4-carboxybenzenediazonium tetrafluoroborate or 4-diazo-N,N-diethylaniline tetrafluoroborate, respectively. Surfactant- and pH-dependent studies confirmed that under conditions that minimized ionic screening effects, separation of these functionalized SWCNTs was strongly dependent on the surface charge density introduced through covalent surface chemistry. For both heterogeneous mixtures and single-chirality-enriched samples, covalently functionalized SWCNTs showed substantially increased peak width in electropherogram spectra compared to nonfunctionalized SWCNTs, which can be attributed to a distribution of surface charges along the functionalized nanotubes. Successful separation of functionalized single-chirality SWCNTs by functional density was confirmed with UV-Vis-NIR absorption and Raman scattering spectroscopies of fraction collected samples. These results suggest a high degree of structural heterogeneity in covalently functionalized SWCNTs, even for chirality-enriched samples, and show the feasibility of applying CE for high-performance separation of nanomaterials based on differences in surface functional density. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. Pulmonary function in women: comparative analysis of conventional versus single-port laparoscopic cholecystectomy

    Directory of Open Access Journals (Sweden)

    MARISA DE CARVALHO BORGES

    2018-05-01

    Full Text Available ABSTRACT Objective: to evaluate the pulmonary function of women submitted to conventional and single-port laparoscopic cholecystectomy. Methods: forty women with symptomatic cholelithiasis, aged 18 to 70 years, participated in the study. We divided the patients into two groups: 21 patients underwent conventional laparoscopic cholecystectomy, and 19, single-port laparoscopic cholecystectomy. We assessed pulmonary function through forced vital capacity (FVC, forced expiratory volume in the first second (FEV1, and the FEV1/FVC ratio, measured before and 24 hours after the procedure. Results: in both groups, FVC and FEV1 were lower in the postoperative period than those obtained in the preoperative period, with a greater reduction in the group undergoing conventional laparoscopic cholecystectomy. Regarding the FEV1/FVC (% values, there was no statistically significant difference in any of the groups or times analyzed. Conclusion: there was a greater decline in FVC and FEV1 in the postoperative group of patients submitted to conventional laparoscopic cholecystectomy.

  3. Normative values for a functional capacity evaluation.

    Science.gov (United States)

    Soer, Remko; van der Schans, Cees P; Geertzen, Jan H; Groothoff, Johan W; Brouwer, Sandra; Dijkstra, Pieter U; Reneman, Michiel F

    2009-10-01

    Soer R, van der Schans CP, Geertzen JH, Groothoff JW, Brouwer S, Dijkstra PU, Reneman MF. Normative values for a functional capacity evaluation. To establish normative values for a functional capacity evaluation (FCE) of healthy working subjects. Descriptive. Rehabilitation center. Healthy working subjects (N=701; 448 men, 253 women) between 20 and 60 years of age, working in more than 180 occupations. Subjects performed a 2-hour FCE consisting of 12 work-related tests. Subjects were classified into categories based on physical demands according to the Dictionary of Occupational Titles. Means, ranges, SDs, and percentiles were provided for normative values of FCE, and a regression analysis for outcome of the 12 tests was performed. Normative FCE values were established for 4 physical demand categories. The normative values enable comparison of patients' performances to these values. If a patient's performance exceeds the lowest scores in his/her corresponding demand category, then the patient's capacity is very likely to be sufficient to meet the workload. Further, clinicians can make more precise return-to-work recommendations and set goals for rehabilitation programs. A comparison of the normative values can be useful to the fields of rehabilitation, occupational, and insurance medicine. Further research is needed to test the validity of the normative values with respect to workplace assessments and return-to-work recommendations.

  4. Challenging Stereotypes: Sexual Functioning of Single Adults with High Functioning Autism Spectrum Disorder

    Science.gov (United States)

    Byers, E. Sandra; Nichols, Shana; Voyer, Susan D.

    2013-01-01

    This study examined the sexual functioning of single adults (61 men, 68 women) with high functioning autism and Asperger syndrome living in the community with and without prior relationship experience. Participants completed an on-line questionnaire assessing autism symptoms, psychological functioning, and various aspects of sexual functioning. In…

  5. Actuarial values calculated using the incomplete Gamma function

    Directory of Open Access Journals (Sweden)

    Giovanni Mingari Scarpello

    2013-03-01

    Full Text Available The complete expectation-of-life for a person and the actuarial present value of continuous life annuities are defined by integrals. In all of them at least one of the factors is a survival function value ratio. If de Moivre’s law of mortality is chosen, such integrals can easily be evaluated; but if the Makeham survival function is adopted, they are used to be calculated numerically. For the above actuarial figures, closed form integrations are hereafter provided by means of the incomplete Gamma function.

  6. Single injection techniques in determining age-related changes in porcine renal function

    International Nuclear Information System (INIS)

    Robbins, M.E.C.

    1984-01-01

    Glomerular filtration rate (GFR) and effective renal plasma flow (ERPF) were determined in 32 anaesthetised female Large White pigs, aged 4-24 months, from the plasma disappearance curves of [sup(99m)Tc]DTPA and [ 131 I]hippuran respectively. Clearance was also monitored by external counting over the heart. GFR and ERPF increased markedly with age in pigs up to 12 months old, reaching mean values of 242.06 +- 5.89 and 919.39 +- 79.01 mL/min. In pigs aged 12-24 months ERPF increased slightly but renal function remained essentially unchanged after 1 yr of age. These results for renal function were similar to previous estimates, using continuous infusion techniques inferring that GFR and ERPF could be accurately monitored using single injection procedures. (author)

  7. On set-valued functionals: Multivariate risk measures and Aumann integrals

    Science.gov (United States)

    Ararat, Cagin

    In this dissertation, multivariate risk measures for random vectors and Aumann integrals of set-valued functions are studied. Both are set-valued functionals with values in a complete lattice of subsets of Rm. Multivariate risk measures are considered in a general d-asset financial market with trading opportunities in discrete time. Specifically, the following features of the market are incorporated in the evaluation of multivariate risk: convex transaction costs modeled by solvency regions, intermediate trading constraints modeled by convex random sets, and the requirement of liquidation into the first m ≤ d of the assets. It is assumed that the investor has a "pure" multivariate risk measure R on the space of m-dimensional random vectors which represents her risk attitude towards the assets but does not take into account the frictions of the market. Then, the investor with a d-dimensional position minimizes the set-valued functional R over all m-dimensional positions that she can reach by trading in the market subject to the frictions described above. The resulting functional Rmar on the space of d-dimensional random vectors is another multivariate risk measure, called the market-extension of R. A dual representation for R mar that decomposes the effects of R and the frictions of the market is proved. Next, multivariate risk measures are studied in a utility-based framework. It is assumed that the investor has a complete risk preference towards each individual asset, which can be represented by a von Neumann-Morgenstern utility function. Then, an incomplete preference is considered for multivariate positions which is represented by the vector of the individual utility functions. Under this structure, multivariate shortfall and divergence risk measures are defined as the optimal values of set minimization problems. The dual relationship between the two classes of multivariate risk measures is constructed via a recent Lagrange duality for set optimization. In

  8. Unified double- and single-sided homogeneous Green's function representations

    Science.gov (United States)

    Wapenaar, Kees; van der Neut, Joost; Slob, Evert

    2016-06-01

    In wave theory, the homogeneous Green's function consists of the impulse response to a point source, minus its time-reversal. It can be represented by a closed boundary integral. In many practical situations, the closed boundary integral needs to be approximated by an open boundary integral because the medium of interest is often accessible from one side only. The inherent approximations are acceptable as long as the effects of multiple scattering are negligible. However, in case of strongly inhomogeneous media, the effects of multiple scattering can be severe. We derive double- and single-sided homogeneous Green's function representations. The single-sided representation applies to situations where the medium can be accessed from one side only. It correctly handles multiple scattering. It employs a focusing function instead of the backward propagating Green's function in the classical (double-sided) representation. When reflection measurements are available at the accessible boundary of the medium, the focusing function can be retrieved from these measurements. Throughout the paper, we use a unified notation which applies to acoustic, quantum-mechanical, electromagnetic and elastodynamic waves. We foresee many interesting applications of the unified single-sided homogeneous Green's function representation in holographic imaging and inverse scattering, time-reversed wave field propagation and interferometric Green's function retrieval.

  9. Value assignment and uncertainty evaluation for single-element reference solutions

    Science.gov (United States)

    Possolo, Antonio; Bodnar, Olha; Butler, Therese A.; Molloy, John L.; Winchester, Michael R.

    2018-06-01

    A Bayesian statistical procedure is proposed for value assignment and uncertainty evaluation for the mass fraction of the elemental analytes in single-element solutions distributed as NIST standard reference materials. The principal novelty that we describe is the use of information about relative differences observed historically between the measured values obtained via gravimetry and via high-performance inductively coupled plasma optical emission spectrometry, to quantify the uncertainty component attributable to between-method differences. This information is encapsulated in a prior probability distribution for the between-method uncertainty component, and it is then used, together with the information provided by current measurement data, to produce a probability distribution for the value of the measurand from which an estimate and evaluation of uncertainty are extracted using established statistical procedures.

  10. Predictive value of different conventional and non-conventional MRI-parameters for specific domains of cognitive function in multiple sclerosis.

    Science.gov (United States)

    Pinter, Daniela; Khalil, Michael; Pichler, Alexander; Langkammer, Christian; Ropele, Stefan; Marschik, Peter B; Fuchs, Siegrid; Fazekas, Franz; Enzinger, Christian

    2015-01-01

    While many studies correlated cognitive function with changes in brain morphology in multiple sclerosis (MS), few of them used a multi-parametric approach in a single dataset so far. We thus here assessed the predictive value of different conventional and quantitative MRI-parameters both for overall and domain-specific cognitive performance in MS patients from a single center. 69 patients (17 clinically isolated syndrome, 47 relapsing-remitting MS, 5 secondary-progressive MS) underwent the "Brief Repeatable Battery of Neuropsychological Tests" assessing overall cognition, cognitive efficiency and memory function as well as MRI at 3 Tesla to obtain T2-lesion load (T2-LL), normalized brain volume (global brain volume loss), normalized cortical volume (NCV), normalized thalamic volume (NTV), normalized hippocampal volume (NHV), normalized caudate nuclei volume (NCNV), basal ganglia R2* values (iron deposition) and magnetization transfer ratios (MTRs) for cortex and normal appearing brain tissue (NABT). Regression models including clinical, demographic variables and MRI-parameters explained 22-27% of variance of overall cognition, 17-26% of cognitive efficiency and 22-23% of memory. NCV, T2-LL and MTR of NABT were the strongest predictors of overall cognitive function. Cognitive efficiency was best predicted by NCV, T2-LL and iron deposition in the basal ganglia. NTV was the strongest predictor for memory function and NHV was particularly related to memory function. The predictive value of distinct MRI-parameters differs for specific domains of cognitive function, with a greater impact of cortical volume, focal and diffuse white matter abnormalities on overall cognitive function, an additional role of basal ganglia iron deposition on cognitive efficiency, and thalamic and hippocampal volume on memory function. This suggests the usefulness of using multiparametric MRI to assess (micro)structural correlates of different cognitive constructs.

  11. Value encoding in single neurons in the human amygdala during decision making.

    Science.gov (United States)

    Jenison, Rick L; Rangel, Antonio; Oya, Hiroyuki; Kawasaki, Hiroto; Howard, Matthew A

    2011-01-05

    A growing consensus suggests that the brain makes simple choices by assigning values to the stimuli under consideration and then comparing these values to make a decision. However, the network involved in computing the values has not yet been fully characterized. Here, we investigated whether the human amygdala plays a role in the computation of stimulus values at the time of decision making. We recorded single neuron activity from the amygdala of awake patients while they made simple purchase decisions over food items. We found 16 amygdala neurons, located primarily in the basolateral nucleus that responded linearly to the values assigned to individual items.

  12. Value functions for certain class of Hamilton Jacobi equations

    Indian Academy of Sciences (India)

    in Rn × R+ and m > 1, with bounded, Lipschitz continuous initial data. We give a. Hopf-Lax type representation for the value function and also characterize the set of minimizing paths. It is shown that the minimizing paths in the representation of value function need not be straight lines. Then we consider HJE with ...

  13. Determination of DB10B values of single and mixed cultures of ...

    African Journals Online (AJOL)

    The survi-ving fraction of isolates decreased with increased irradiation doses. DB10B values of E. coli, S. aureus and S. parat-hyphi B were respectively 0.27, 0.33 and 0.44 kGy when inoculated as single cultures, and 0.24, 0.28 and 0.32 kGy respectively when inoculated as mixed cultures. DB10B values were lower for ...

  14. SYNTHESIS METHODS OF ALGEBRAIC NORMAL FORM OF MANY-VALUED LOGIC FUNCTIONS

    Directory of Open Access Journals (Sweden)

    A. V. Sokolov

    2016-01-01

    Full Text Available The rapid development of methods of error-correcting coding, cryptography, and signal synthesis theory based on the principles of many-valued logic determines the need for a more detailed study of the forms of representation of functions of many-valued logic. In particular the algebraic normal form of Boolean functions, also known as Zhegalkin polynomial, that well describe many of the cryptographic properties of Boolean functions is widely used. In this article, we formalized the notion of algebraic normal form for many-valued logic functions. We developed a fast method of synthesis of algebraic normal form of 3-functions and 5-functions that work similarly to the Reed-Muller transform for Boolean functions: on the basis of recurrently synthesized transform matrices. We propose the hypothesis, which determines the rules of the synthesis of these matrices for the transformation from the truth table to the coefficients of the algebraic normal form and the inverse transform for any given number of variables of 3-functions or 5-functions. The article also introduces the definition of algebraic degree of nonlinearity of the functions of many-valued logic and the S-box, based on the principles of many-valued logic. Thus, the methods of synthesis of algebraic normal form of 3-functions applied to the known construction of recurrent synthesis of S-boxes of length N = 3k, whereby their algebraic degrees of nonlinearity are computed. The results could be the basis for further theoretical research and practical applications such as: the development of new cryptographic primitives, error-correcting codes, algorithms of data compression, signal structures, and algorithms of block and stream encryption, all based on the perspective principles of many-valued logic. In addition, the fast method of synthesis of algebraic normal form of many-valued logic functions is the basis for their software and hardware implementation.

  15. Timelike single-logarithm-resummed splitting functions

    Energy Technology Data Exchange (ETDEWEB)

    Albino, S.; Bolzoni, P.; Kniehl, B.A. [Hamburg Univ. (Germany). 2. Inst. fuer Theoretische Physik; Kotikov, A.V. [Hamburg Univ. (Germany). 2. Inst. fuer Theoretische Physik; Joint Inst. of Nuclear Research, Moscow (Russian Federation). Bogoliubov Lab. of Theoretical Physics

    2011-08-15

    We calculate the single logarithmic contributions to the quark singlet and gluon matrix of timelike splitting functions at all orders in the modified minimal-subtraction (MS) scheme. We fix two of the degrees of freedom of this matrix from the analogous results in the massive-gluon regularization scheme by using the relation between that scheme and the MS scheme. We determine this scheme transformation from the double logarithmic contributions to the timelike splitting functions and the coefficient functions of inclusive particle production in e{sup +}e{sup -} annihilation now available in both schemes. The remaining two degrees of freedom are fixed by reasonable physical assumptions. The results agree with the fixed-order results at next-to-next-to-leading order in the literature. (orig.)

  16. How Patent Function Integration with R&D Influence the Value of Patents

    DEFF Research Database (Denmark)

    Beukel, Karin; Valentin, Finn

    Patent strategies are endogenous to firm appropriability. However, to what extent does firm’s R&D teams’ engagement with patent experts influence the value of patents? We estimate the relationship between firm’s R&D use of patent functions on patent value in Biotech firms. Controlling...... for characteristics of scientific team, firm effects, and other patent value indicators, we find that having a firm specific (in-house) internal patent function is a driver of patent value. In addition, we find that the way in which patent functions create patent value differs dependent on whether the firm has...... internal patent function or not. In-house patent functions create value through narrow patents, whereas, firms with no in-house patent function create valuable patents by the use of broader scoped patents. Our results point to a strong effect of firm specific patent functions, but also explain how firms...

  17. Uncertainty of Monetary Valued Ecosystem Services - Value Transfer Functions for Global Mapping.

    Directory of Open Access Journals (Sweden)

    Stefan Schmidt

    Full Text Available Growing demand of resources increases pressure on ecosystem services (ES and biodiversity. Monetary valuation of ES is frequently seen as a decision-support tool by providing explicit values for unconsidered, non-market goods and services. Here we present global value transfer functions by using a meta-analytic framework for the synthesis of 194 case studies capturing 839 monetary values of ES. For 12 ES the variance of monetary values could be explained with a subset of 93 study- and site-specific variables by utilizing boosted regression trees. This provides the first global quantification of uncertainties and transferability of monetary valuations. Models explain from 18% (water provision to 44% (food provision of variance and provide statistically reliable extrapolations for 70% (water provision to 91% (food provision of the terrestrial earth surface. Although the application of different valuation methods is a source of uncertainty, we found evidence that assuming homogeneity of ecosystems is a major error in value transfer function models. Food provision is positively correlated with better life domains and variables indicating positive conditions for human well-being. Water provision and recreation service show that weak ownerships affect valuation of other common goods negatively (e.g. non-privately owned forests. Furthermore, we found support for the shifting baseline hypothesis in valuing climate regulation. Ecological conditions and societal vulnerability determine valuation of extreme event prevention. Valuation of habitat services is negatively correlated with indicators characterizing less favorable areas. Our analysis represents a stepping stone to establish a standardized integration of and reporting on uncertainties for reliable and valid benefit transfer as an important component for decision support.

  18. Dominance-based ranking functions for interval-valued intuitionistic fuzzy sets.

    Science.gov (United States)

    Chen, Liang-Hsuan; Tu, Chien-Cheng

    2014-08-01

    The ranking of interval-valued intuitionistic fuzzy sets (IvIFSs) is difficult since they include the interval values of membership and nonmembership. This paper proposes ranking functions for IvIFSs based on the dominance concept. The proposed ranking functions consider the degree to which an IvIFS dominates and is not dominated by other IvIFSs. Based on the bivariate framework and the dominance concept, the functions incorporate not only the boundary values of membership and nonmembership, but also the relative relations among IvIFSs in comparisons. The dominance-based ranking functions include bipolar evaluations with a parameter that allows the decision-maker to reflect his actual attitude in allocating the various kinds of dominance. The relationship for two IvIFSs that satisfy the dual couple is defined based on four proposed ranking functions. Importantly, the proposed ranking functions can achieve a full ranking for all IvIFSs. Two examples are used to demonstrate the applicability and distinctiveness of the proposed ranking functions.

  19. Computation of Value Functions in Nonlinear Differential Games with State Constraints

    KAUST Repository

    Botkin, Nikolai; Hoffmann, Karl-Heinz; Mayer, Natalie; Turova, Varvara

    2013-01-01

    Finite-difference schemes for the computation of value functions of nonlinear differential games with non-terminal payoff functional and state constraints are proposed. The solution method is based on the fact that the value function is a

  20. How we can Transform the Constant Alpha Value into a Variable Function

    International Nuclear Information System (INIS)

    Acosta P, C.F.; Sordi, G.M.A.A.

    2006-01-01

    For the cost-benefit analysis used in the quantitative decision aiding techniques the alpha value is the aim of the question, because it is the alpha value that, directly or indirectly determines the analytical solution Y, consequently, the workers doses distribution involved with ionizing radiation source. Currently, each country adopts a single alpha value that can be linked to the annual gross product (GNP) per capita. Otherwise, the risks due to the ionizing radiation practices Y the ultimate objective, that is, to decrease the doses to admissible levels, are the same in any place of the world. In this case, it seems reasonable to think that the alpha value would be the same in every country. With this view, this paper has the objective to present, as suggestion, how it is possible to make a variable of the alpha value. To achieve this goal using a rigorous mathematical model, the protection options were linked by a curve selected among several curves that best fit in place of the straight line as the ICRP does. The curve selection was applied to the small uranium mine example provide by ICRP in publication number 55. Introducing a variable alpha value as function of the highest individual dose, their values will not depend on the GNP per capita anymore, but on the maximum individual dose distribution Y the length of time necessary to comprise, if possible, the aim of 1/10 of the annual dose limits for workers foreseen in the successive optimizations, that is, to range the individual dose zone considered acceptable. (Author)

  1. How we can Transform the Constant Alpha Value into a Variable Function

    Energy Technology Data Exchange (ETDEWEB)

    Acosta P, C.F.; Sordi, G.M.A.A. [Instituto de Pesquisas Energeticas e Nucleares, Sao Paulo (Brazil)]. e-mail: cani@osite.com.br

    2006-07-01

    For the cost-benefit analysis used in the quantitative decision aiding techniques the alpha value is the aim of the question, because it is the alpha value that, directly or indirectly determines the analytical solution Y, consequently, the workers doses distribution involved with ionizing radiation source. Currently, each country adopts a single alpha value that can be linked to the annual gross product (GNP) per capita. Otherwise, the risks due to the ionizing radiation practices Y the ultimate objective, that is, to decrease the doses to admissible levels, are the same in any place of the world. In this case, it seems reasonable to think that the alpha value would be the same in every country. With this view, this paper has the objective to present, as suggestion, how it is possible to make a variable of the alpha value. To achieve this goal using a rigorous mathematical model, the protection options were linked by a curve selected among several curves that best fit in place of the straight line as the ICRP does. The curve selection was applied to the small uranium mine example provide by ICRP in publication number 55. Introducing a variable alpha value as function of the highest individual dose, their values will not depend on the GNP per capita anymore, but on the maximum individual dose distribution Y the length of time necessary to comprise, if possible, the aim of 1/10 of the annual dose limits for workers foreseen in the successive optimizations, that is, to range the individual dose zone considered acceptable. (Author)

  2. Unified double- and single-sided homogeneous Green’s function representations

    Science.gov (United States)

    van der Neut, Joost; Slob, Evert

    2016-01-01

    In wave theory, the homogeneous Green’s function consists of the impulse response to a point source, minus its time-reversal. It can be represented by a closed boundary integral. In many practical situations, the closed boundary integral needs to be approximated by an open boundary integral because the medium of interest is often accessible from one side only. The inherent approximations are acceptable as long as the effects of multiple scattering are negligible. However, in case of strongly inhomogeneous media, the effects of multiple scattering can be severe. We derive double- and single-sided homogeneous Green’s function representations. The single-sided representation applies to situations where the medium can be accessed from one side only. It correctly handles multiple scattering. It employs a focusing function instead of the backward propagating Green’s function in the classical (double-sided) representation. When reflection measurements are available at the accessible boundary of the medium, the focusing function can be retrieved from these measurements. Throughout the paper, we use a unified notation which applies to acoustic, quantum-mechanical, electromagnetic and elastodynamic waves. We foresee many interesting applications of the unified single-sided homogeneous Green’s function representation in holographic imaging and inverse scattering, time-reversed wave field propagation and interferometric Green’s function retrieval. PMID:27436983

  3. Prevalence of normal TSH value among patients with autonomously functioning thyroid nodule.

    Science.gov (United States)

    Treglia, Giorgio; Trimboli, Pierpaolo; Verburg, Frederik A; Luster, Markus; Giovanella, Luca

    2015-07-01

    International guidelines significantly diverge on the effectiveness of thyroid scintigraphy (TS) in the initial work-up of thyroid nodules. In particular, the role of TS to detect or exclude the presence of autonomously functioning thyroid nodules (AFTN) in patients with normal serum thyrotropin (TSH) is still a matter to debate. Here, we aimed to review the literature on the prevalence of normal TSH value among patients with AFTN and meta-analyse data of the retrieved eligible papers. A comprehensive literature search of studies published from January 2000 to December 2014 on AFTN detected by TS was performed. Records reporting serum TSH values in AFTN were selected. Pooled prevalence of AFTN with normal TSH values was calculated on a per-patient analysis including 95% confidence intervals (95% CI). Eight records including 2761 AFTN were selected for the meta-analysis. Pooled prevalence of AFTN with normal TSH detected by TS was 50% (95% CI: 32-68%). Selection bias in the included studies and heterogeneity among studies were potential limitations of the meta-analysis. Present meta-analysis shows that about one in two patients with AFTN demonstrated by TS has a TSH value within normal references. As a consequence, TSH measurement may not be considered as effective as a single tool to detect or exclude AFTN, and TS remains mandatory. © 2015 Stichting European Society for Clinical Investigation Journal Foundation.

  4. Multi-Valued Logic Gates, Continuous Sensitivity, Reversibility, and Threshold Functions

    OpenAIRE

    İlhan, Aslı Güçlükan; Ünlü, Özgün

    2016-01-01

    We define an invariant of a multi-valued logic gate by considering the number of certain threshold functions associated with the gate. We call this invariant the continuous sensitivity of the gate. We discuss a method for analysing continuous sensitivity of a multi-valued logic gate by using experimental data about the gate. In particular, we will show that this invariant provides a lower bound for the sensitivity of a boolean function considered as a multi-valued logic gate. We also discuss ...

  5. Developing rapid methods for analyzing upland riparian functions and values.

    Science.gov (United States)

    Hruby, Thomas

    2009-06-01

    Regulators protecting riparian areas need to understand the integrity, health, beneficial uses, functions, and values of this resource. Up to now most methods providing information about riparian areas are based on analyzing condition or integrity. These methods, however, provide little information about functions and values. Different methods are needed that specifically address this aspect of riparian areas. In addition to information on functions and values, regulators have very specific needs that include: an analysis at the site scale, low cost, usability, and inclusion of policy interpretations. To meet these needs a rapid method has been developed that uses a multi-criteria decision matrix to categorize riparian areas in Washington State, USA. Indicators are used to identify the potential of the site to provide a function, the potential of the landscape to support the function, and the value the function provides to society. To meet legal needs fixed boundaries for assessment units are established based on geomorphology, the distance from "Ordinary High Water Mark" and different categories of land uses. Assessment units are first classified based on ecoregions, geomorphic characteristics, and land uses. This simplifies the data that need to be collected at a site, but it requires developing and calibrating a separate model for each "class." The approach to developing methods is adaptable to other locations as its basic structure is not dependent on local conditions.

  6. Normative Values for a Functional Capacity Evaluation

    NARCIS (Netherlands)

    Soer, Remko; van der Schans, Cees P.; Geertzen, Jan H.; Groothoff, Johan W.; Brouwer, Sandra; Dijkstra, Pieter U.; Reneman, Michiel F.

    2009-01-01

    Objective: To establish normative values for a functional capacity evaluation (FCE) of healthy working subjects. Design: Descriptive. Setting: Rehabilitation center. Participants: Healthy working subjects (N=701; 448 men, 253 women) between 20 and 60 years of age, working in more than 180

  7. The Value Range of Contact Stiffness Factor between Pile and Soil Based on Penalty Function

    Science.gov (United States)

    Chen, Sandy H. L.; Wu, Xinliu

    2018-03-01

    The value range of contact stiffness factor based on penalty function is studied when we use finite element software ANSYS to analyze contact problems, take single pile and soil of a certain project for example, the normal contact between pile and soil is analyzed with 2D simplified model in horizontal load. The study shows that when adopting linear elastic model to simulate soil, the maximum contact pressure and penetration approach steady value as the contact stiffness factor increases. The reasonable value range of contact stiffness factor reduces as the underlying element thickness decreases, but the rule reverses when refers to the soil stiffness. If choose DP model to simulate soil, the stiffness factor should be magnified 100 times compares to the elastic model regardless of the soil bears small force and still in elastic deformation stage or into the plastic deformation stage. When the soil bears big force and into plastic deformation stage, the value range of stiffness factor relates to the plastic strain range of the soil, and reduces as the horizontal load increases.

  8. Uncertainty of Monetary Valued Ecosystem Services – Value Transfer Functions for Global Mapping

    Science.gov (United States)

    Schmidt, Stefan; Manceur, Ameur M.; Seppelt, Ralf

    2016-01-01

    Growing demand of resources increases pressure on ecosystem services (ES) and biodiversity. Monetary valuation of ES is frequently seen as a decision-support tool by providing explicit values for unconsidered, non-market goods and services. Here we present global value transfer functions by using a meta-analytic framework for the synthesis of 194 case studies capturing 839 monetary values of ES. For 12 ES the variance of monetary values could be explained with a subset of 93 study- and site-specific variables by utilizing boosted regression trees. This provides the first global quantification of uncertainties and transferability of monetary valuations. Models explain from 18% (water provision) to 44% (food provision) of variance and provide statistically reliable extrapolations for 70% (water provision) to 91% (food provision) of the terrestrial earth surface. Although the application of different valuation methods is a source of uncertainty, we found evidence that assuming homogeneity of ecosystems is a major error in value transfer function models. Food provision is positively correlated with better life domains and variables indicating positive conditions for human well-being. Water provision and recreation service show that weak ownerships affect valuation of other common goods negatively (e.g. non-privately owned forests). Furthermore, we found support for the shifting baseline hypothesis in valuing climate regulation. Ecological conditions and societal vulnerability determine valuation of extreme event prevention. Valuation of habitat services is negatively correlated with indicators characterizing less favorable areas. Our analysis represents a stepping stone to establish a standardized integration of and reporting on uncertainties for reliable and valid benefit transfer as an important component for decision support. PMID:26938447

  9. Normative Functional Performance Values in High School Athletes: The Functional Pre-Participation Evaluation Project.

    Science.gov (United States)

    Onate, James A; Starkel, Cambrie; Clifton, Daniel R; Best, Thomas M; Borchers, James; Chaudhari, Ajit; Comstock, R Dawn; Cortes, Nelson; Grooms, Dustin R; Hertel, Jay; Hewett, Timothy E; Miller, Meghan Maume; Pan, Xueliang; Schussler, Eric; Van Lunen, Bonnie L

    2018-01-01

      The fourth edition of the Preparticipation Physical Evaluation recommends functional testing for the musculoskeletal portion of the examination; however, normative data across sex and grade level are limited. Establishing normative data can provide clinicians reference points with which to compare their patients, potentially aiding in the development of future injury-risk assessments and injury-mitigation programs.   To establish normative functional performance and limb-symmetry data for high school-aged male and female athletes in the United States.   Cross-sectional study.   Athletic training facilities and gymnasiums across the United States.   A total of 3951 male and female athletes who participated on high school-sponsored basketball, football, lacrosse, or soccer teams enrolled in this nationwide study.   Functional performance testing consisted of 3 evaluations. Ankle-joint range of motion, balance, and lower extremity muscular power and landing control were assessed via the weight-bearing ankle-dorsiflexion-lunge, single-legged anterior-reach, and anterior single-legged hop-for-distance (SLHOP) tests, respectively. We used 2-way analyses of variance and χ 2 analyses to examine the effects of sex and grade level on ankle-dorsiflexion-lunge, single-legged anterior-reach, and SLHOP test performance and symmetry.   The SLHOP performance differed between sexes (males = 187.8% ± 33.1% of limb length, females = 157.5% ± 27.8% of limb length; t = 30.3, P performance. We observed differences for SLHOP and ankle-dorsiflexion-lunge performance among grade levels, but these differences were not clinically meaningful.   We demonstrated differences in normative data for lower extremity functional performance during preparticipation physical evaluations across sex and grade levels. The results of this study will allow clinicians to compare sex- and grade-specific functional performances and implement approaches for preventing musculoskeletal

  10. Challenging stereotypes: sexual functioning of single adults with high functioning autism spectrum disorder.

    Science.gov (United States)

    Byers, E Sandra; Nichols, Shana; Voyer, Susan D

    2013-11-01

    This study examined the sexual functioning of single adults (61 men, 68 women) with high functioning autism and Asperger syndrome living in the community with and without prior relationship experience. Participants completed an on-line questionnaire assessing autism symptoms, psychological functioning, and various aspects of sexual functioning. In general participants reported positive sexual functioning. Participants without prior relationship experience were significantly younger and more likely to be male and identify as heterosexual. They reported significantly higher sexual anxiety, lower sexual arousability, lower dyadic desire, and fewer positive sexual cognitions. The men reported better sexual function than did the women in a number of areas. These results counter negative societal perceptions about the sexuality of high functioning individuals on the autism spectrum.

  11. Approximation Of Multi-Valued Inverse Functions Using Clustering And Sugeno Fuzzy Inference

    Science.gov (United States)

    Walden, Maria A.; Bikdash, Marwan; Homaifar, Abdollah

    1998-01-01

    Finding the inverse of a continuous function can be challenging and computationally expensive when the inverse function is multi-valued. Difficulties may be compounded when the function itself is difficult to evaluate. We show that we can use fuzzy-logic approximators such as Sugeno inference systems to compute the inverse on-line. To do so, a fuzzy clustering algorithm can be used in conjunction with a discriminating function to split the function data into branches for the different values of the forward function. These data sets are then fed into a recursive least-squares learning algorithm that finds the proper coefficients of the Sugeno approximators; each Sugeno approximator finds one value of the inverse function. Discussions about the accuracy of the approximation will be included.

  12. Single-particle energies and density of states in density functional theory

    Science.gov (United States)

    van Aggelen, H.; Chan, G. K.-L.

    2015-07-01

    Time-dependent density functional theory (TD-DFT) is commonly used as the foundation to obtain neutral excited states and transition weights in DFT, but does not allow direct access to density of states and single-particle energies, i.e. ionisation energies and electron affinities. Here we show that by extending TD-DFT to a superfluid formulation, which involves operators that break particle-number symmetry, we can obtain the density of states and single-particle energies from the poles of an appropriate superfluid response function. The standard Kohn- Sham eigenvalues emerge as the adiabatic limit of the superfluid response under the assumption that the exchange- correlation functional has no dependence on the superfluid density. The Kohn- Sham eigenvalues can thus be interpreted as approximations to the ionisation energies and electron affinities. Beyond this approximation, the formalism provides an incentive for creating a new class of density functionals specifically targeted at accurate single-particle eigenvalues and bandgaps.

  13. Determination of D10 values of single and mixed cultures of bacteria after gamma irradiation

    International Nuclear Information System (INIS)

    Adu-Gyamfi, A.; Nketsia-Tabiri, J.; Boatin, R.

    2009-01-01

    The D 10 value of bacteria represents the absorbed radiation dose required to inactivate 90 % of a viable population or reduce the population by a factor of 10. D 10 values of 3 bacterial isolates (Escherichia coli, Staphylococcus aureus and Salmonella parathyphi B) were determined using single and mixed cultures to assess the effect of microbial competition on radiosensitivity. The isolates were inoculated into wakye substrate and exposed to γ-radiation doses of 0, 100, 300, 450, 600, 750, 850 Gy from a 6O Co source at a dose rate of 2.20 kGy/h in air. Enumeration of survivors of the isolates was carried out using serial dilution and pour plate methods. The surviving fraction of isolates decreased with increased irradiation doses. D 10 values of E. coli, S. aureus and S. parathyphi B were respectively 0.27, 0.33 and 0.44 kGy when inoculated as single cultures, and 0.24, 0.28 and 0.32 kGy respectively when inoculated as mixed cultures. D 10 values were lower for mixed cultures compared to single cultures, which might indicate reduced resistance to γ-radiation as a result of competition among the isolates. Microbiological challenge tests based on the D 10 values may result in delivery of higher irradiation doses, but the extra dose could serve as safety margin to enhance the food preservative capacity of radiation processing. (au)

  14. FUZZY LOGIC BASED OPTIMIZATION OF CAPACITOR VALUE FOR SINGLE PHASE OPEN WELL SUBMERSIBLE INDUCTION MOTOR

    Directory of Open Access Journals (Sweden)

    R. Subramanian

    2011-01-01

    Full Text Available Purpose – The aim of this paper is to optimize the capacitor value of a single phase open well submersible motor operating under extreme voltage conditions using fuzzy logic optimization technique and compared with no-load volt-ampere method. This is done by keeping the displacement angle (a between main winding and auxiliary winding near 90o, phase angle (f between the supply voltage and line current near 0o. The optimization work is carried out by using Fuzzy Logic Toolbox software built on the MATLAB technical computing environment with Simulink software. Findings – The optimum capacitor value obtained is used with a motor and tested for different supply voltage conditions. The vector diagrams obtained from the experimental test results indicates that the performance is improved from the existing value. Originality/value – This method will be highly useful for the practicing design engineers in selecting the optimum capacitance value for single phase induction motors to achieve the best performance for operating at extreme supply voltage conditions.

  15. Stimulus-response functions of single avian olfactory bulb neurones.

    Science.gov (United States)

    McKeegan, Dorothy E F; Demmers, Theodorus G M; Wathes, Christopher M; Jones, R Bryan; Gentle, Michael J

    2002-10-25

    This study investigated olfactory processing in a functional context by examining the responses of single avian olfactory bulb neurones to two biologically important gases over relevant concentration ranges. Recordings of extracellular spike activity were made from 80 single units in the left olfactory bulb of 11 anaesthetised, freely breathing adult hens (Gallus domesticus). The units were spontaneously active, exhibiting widely variable firing rates (0.07-47.28 spikes/s) and variable temporal firing patterns. Single units were tested for their response to an ascending concentration series of either ammonia (2.5-100 ppm) or hydrogen sulphide (1-50 ppm), delivered directly to the olfactory epithelium. Stimulation with a calibrated gas delivery system resulted in modification of spontaneous activity causing either inhibition (47% of units) or excitation (53%) of firing. For ammonia, 20 of the 35 units tested exhibited a response, while for hydrogen sulphide, 25 of the 45 units tested were responsive. Approximate response thresholds for ammonia (median threshold 3.75 ppm (range 2.5-60 ppm, n=20)) and hydrogen sulphide (median threshold 1 ppm (range 1-10 ppm, n=25)) were determined with most units exhibiting thresholds near the lower end of these ranges. Stimulus response curves were constructed for 23 units; 16 (the most complete) were subjected to a linear regression analysis to determine whether they were best fitted by a linear, log or power function. No single function provided the best fit for all the curves (seven were linear, eight were log, one was power). These findings show that avian units respond to changes in stimulus concentration in a manner generally consistent with reported responses in mammalian olfactory bulb neurones. However, this study illustrates a level of fine-tuning to small step changes in concentration (<5 ppm) not previously demonstrated in vertebrate single olfactory bulb neurones.

  16. Prediction of postoperative pulmonary function. Preliminary comparison of single-breath dual-energy xenon CT with three conventional methods

    International Nuclear Information System (INIS)

    Yanagita, Hisami; Honda, Norinari; Nakayama, Mitsuo

    2013-01-01

    The purpose of this study was to assess the use of xenon ventilation maps (Xe-images) for predicting postoperative pulmonary function. After study approval by the institutional review board, written informed consent was obtained from 30 patients with lung tumors who underwent pre- and postoperative spirometry, pulmonary perfusion single photon emission computed tomography (SPECT) and dual-energy CT (80 kV and 140 kV/Sn) after single-breath inspiration of 35% xenon. Xe-images were calculated by three-material decomposition. Sum of pixel values of the part to be resected (A) and of the whole lung (B) on Xe-images or lung perfusion SPECT, and volumes or the number of segments of the part to be resected (A) and of the whole lung (B) on Xe-images were enumerated, respectively. We multiplied (1-A/B) by each preoperative value from spirometry for prediction. Predictions by each of the four methods were compared with postoperative values. Predicted values for vital capacity (VC), forced vital capacity (FVC) and forced expiratory volume in 1 s (FEV 1 ) by the four methods regressed significantly with measured values (R 2 =0.56-0.77, p 1 with accuracy comparable to that of CT volumetry. (author)

  17. Single proteins that serve linked functions in intracellular and extracellular microenvironments

    Energy Technology Data Exchange (ETDEWEB)

    Radisky, Derek C.; Stallings-Mann, Melody; Hirai, Yohei; Bissell, Mina J.

    2009-06-03

    Maintenance of organ homeostasis and control of appropriate response to environmental alterations requires intimate coordination of cellular function and tissue organization. An important component of this coordination may be provided by proteins that can serve distinct, but linked, functions on both sides of the plasma membrane. Here we present a novel hypothesis in which non-classical secretion can provide a mechanism through which single proteins can integrate complex tissue functions. Single genes can exert a complex, dynamic influence through a number of different processes that act to multiply the function of the gene product(s). Alternative splicing can create many different transcripts that encode proteins of diverse, even antagonistic, function from a single gene. Posttranslational modifications can alter the stability, activity, localization, and even basic function of proteins. A protein can exist in different subcellular localizations. More recently, it has become clear that single proteins can function both inside and outside the cell. These proteins often lack defined secretory signal sequences, and transit the plasma membrane by mechanisms separate from the classical ER/Golgi secretory process. When examples of such proteins are examined individually, the multifunctionality and lack of a signal sequence are puzzling - why should a protein with a well known function in one context function in such a distinct fashion in another? We propose that one reason for a single protein to perform intracellular and extracellular roles is to coordinate organization and maintenance of a global tissue function. Here, we describe in detail three specific examples of proteins that act in this fashion, outlining their specific functions in the extracellular space and in the intracellular space, and we discuss how these functions may be linked. We present epimorphin/syntaxin-2, which may coordinate morphogenesis of secretory organs (as epimorphin) with control of

  18. On the Stone-Weierstrass theorem for scalar and vector valued functions

    International Nuclear Information System (INIS)

    Khan, L.A.

    1991-09-01

    In this paper we discuss the formulation of the Stone-Weierstrass approximation theorem for vector-valued functions and then determine whether the classical Stone-Weierstrass theorem for scalar-valued functions can be deduced from the above one. We also state some open problems in this area. (author). 15 refs

  19. Kernel Function Tuning for Single-Layer Neural Networks

    Czech Academy of Sciences Publication Activity Database

    Vidnerová, Petra; Neruda, Roman

    -, accepted 28.11. 2017 (2018) ISSN 2278-0149 R&D Projects: GA ČR GA15-18108S Institutional support: RVO:67985807 Keywords : single-layer neural networks * kernel methods * kernel function * optimisation Subject RIV: IN - Informatics, Computer Science http://www.ijmerr.com/

  20. Genetics and evolution of function-valued traits: understanding environmentally responsive phenotypes.

    Science.gov (United States)

    Stinchcombe, John R; Kirkpatrick, Mark

    2012-11-01

    Many central questions in ecology and evolutionary biology require characterizing phenotypes that change with time and environmental conditions. Such traits are inherently functions, and new 'function-valued' methods use the order, spacing, and functional nature of the data typically ignored by traditional univariate and multivariate analyses. These rapidly developing methods account for the continuous change in traits of interest in response to other variables, and are superior to traditional summary-based analyses for growth trajectories, morphological shapes, and environmentally sensitive phenotypes. Here, we explain how function-valued methods make flexible use of data and lead to new biological insights. These approaches frequently offer enhanced statistical power, a natural basis of interpretation, and are applicable to many existing data sets. We also illustrate applications of function-valued methods to address ecological, evolutionary, and behavioral hypotheses, and highlight future directions. Copyright © 2012 Elsevier Ltd. All rights reserved.

  1. Research on establishing the rank and quotient of functions in product value analysisengineering

    Directory of Open Access Journals (Sweden)

    Gheorghe Burz

    2011-12-01

    Full Text Available The constructive conception of a product results from uniting subsystems with basic usage values. These basic usage values make up the functions of the product. The notion of product function is the basic notion that product value analysis/value engineering(VA/VE operates with, and function analysis together with creative thinking constitutes „the oxygen of value engineering”. The present paper defines the notion of rank of a product function, establishes the formula for calculating its value and it reviews some ways of Determining the levels of importance of product functions, with the aim of proposing a new distribution of the importance of these Functions within the total usage value. Establishing the rank of a function can be reduced to the issue of comparing product functions by experts, consumers, team members for VA/VE. Subsequently, the ensuing results are subjected to adequate mathematical operations in order to determin the levels of importance and the quotients of each function within the product ussage value, as well as the distribution of these quotients. Due to the fact that the quota or quotient of a function within the product usage value plays an important role in conceiving and designing products, more precisely, in the economical shaping of functions, the distribution law to which this parametre is subjected is also very important. A critical study of the methods currently used to determine function quotients shows that these methods conduct to a linear distribution of these quotients, and, under these Circumstances, the ratio between the highest level of importance and the lowest level of importance is equal to the number of functions – number that is very high indeed for complex products. On the other hand, it is rightly assumed that there is a considerable number of products for which the functions do not follow a linear distribution. The Zipf distribution or its generalised form, the Pareto

  2. BSDES IN GAMES, COUPLED WITH THE VALUE FUNCTIONS.ASSOCIATED NONLOCAL BELLMAN-ISAACS EQUATIONS

    Institute of Scientific and Technical Information of China (English)

    Tao HAO; Juan LI

    2017-01-01

    We establish a new type of backward stochastic differential equations (BSDEs) connected with stochastic differential games (SDGs),namely,BSDEs strongly coupled with the lower and the upper value functions of SDGs,where the lower and the upper value functions are defined through this BSDE.The existence and the uniqueness theorem and comparison theorem are proved for such equations with the help of an iteration method.We also show that the lower and the upper value functions satisfy the dynamic programming principle.Moreover,we study the associated Hamilton-Jacobi-Bellman-Isaacs (HJB-Isaacs) equations,which are nonlocal,and strongly coupled with the lower and the upper value functions.Using a new method,we characterize the pair (W,U) consisting of the lower and the upper value functions as the unique viscosity solution of our nonlocal HJB-Isaacs equation.Furthermore,the game has a value under the Isaacs' condition.

  3. Functionalized single-walled carbon nanotube-based fuel cell benchmarked against US DOE 2017 technical targets.

    Science.gov (United States)

    Jha, Neetu; Ramesh, Palanisamy; Bekyarova, Elena; Tian, Xiaojuan; Wang, Feihu; Itkis, Mikhail E; Haddon, Robert C

    2013-01-01

    Chemically modified single-walled carbon nanotubes (SWNTs) with varying degrees of functionalization were utilized for the fabrication of SWNT thin film catalyst support layers (CSLs) in polymer electrolyte membrane fuel cells (PEMFCs), which were suitable for benchmarking against the US DOE 2017 targets. Use of the optimum level of SWNT -COOH functionality allowed the construction of a prototype SWNT-based PEMFC with total Pt loading of 0.06 mg(Pt)/cm²--well below the value of 0.125 mg(Pt)/cm² set as the US DOE 2017 technical target for total Pt group metals (PGM) loading. This prototype PEMFC also approaches the technical target for the total Pt content per kW of power (<0.125 g(PGM)/kW) at cell potential 0.65 V: a value of 0.15 g(Pt)/kW was achieved at 80°C/22 psig testing conditions, which was further reduced to 0.12 g(Pt)/kW at 35 psig back pressure.

  4. Temperature response functions (G-functions) for single pile heat exchangers

    International Nuclear Information System (INIS)

    Loveridge, Fleur; Powrie, William

    2013-01-01

    Foundation piles used as heat exchangers as part of a ground energy system have the potential to reduce energy use and carbon dioxide emissions from new buildings. However, current design approaches for pile heat exchangers are based on methods developed for boreholes which have a different geometry, with a much larger aspect (length to diameter) ratio. Current methods also neglect the transient behaviour of the pile concrete, instead assuming a steady state resistance for design purposes. As piles have a much larger volume of concrete than boreholes, this neglects the significant potential for heat storage within the pile. To overcome these shortcomings this paper presents new pile temperature response functions (G-functions) which are designed to reflect typical geometries of pile heat exchangers and include the transient response of the pile concrete. Owing to the larger number of pile sizes and pipe configurations which are possible with pile heat exchangers it is not feasible to developed a single unified G-function and instead upper and lower bound solutions are provided for different aspects ratios. - Highlights: • We present new temperature response functions for pile heat exchangers. • The functions include transient heat transfer within the pile concrete. • Application of the functions reduces the resulting calculated temperature ranges. • Greater energy efficiency is possible by accounting for heat storage in the pile

  5. Assessment of left ventricular function by electrocardiogram-gated myocardial single photon emission computed tomography using quantitative gated single photon emission computed tomography software

    International Nuclear Information System (INIS)

    Morita, Koichi; Adachi, Itaru; Konno, Masanori

    1999-01-01

    Electrocardiogram (ECG)-gated myocardial single photon emission computed tomography (SPECT) can assess left ventricular (LV) perfusion and function easily using quantitative gated SPECT (QGS) software. ECG-gated SPECT was performed in 44 patients with coronary artery disease under post-stress and resting conditions to assess the values of LV functional parameters, by comparison to LV ejection fraction derived from gated blood pool scan and myocardial characteristics. A good correlation was obtained between ejection fraction using QGS and that using cardiac blood pool scan (r=0.812). Some patients with myocardial ischemia had lower ejection fraction under post-stress compared to resting conditions, indicating post-stress LV dysfunction. LV wall motion and wall thickening were significantly impaired in ischemic and infarcted myocardium, and the degree of abnormality in the infarcted areas was greater than in the ischemia area. LV functional parameters derived using QGS were useful to assess post-stress LV dysfunction and myocardial viability. In conclusion, ECG-gated myocardial SPECT permits simultaneous quantitative assessment of myocardial perfusion and function. (author)

  6. Analysis of the Functional Independence Measure Value of Cervical Spine Injury Patients with Conservative Management

    Directory of Open Access Journals (Sweden)

    M. Zafrullah Arifin

    2012-06-01

    Full Text Available Analysis of the Functional Independence Measure Value of Cervical Spine Injury Patients with Conservative Management. Cervical spine injury is one of the most common spinal cord injuries in trauma patients. From 100,000 spinal cord injury cases reported in the United States of America (2008, sixty seven percent involve cervical spine injury. American Spinal Cord Injury Association (ASIA impairment score is used as an initial assessment but not enough attention prognostic outcome of these patients was paid to. The objective of this study is to analyze the value of functional independence measure (FIM cervical spine injury patients with conservative management and its correlation with age, sex, type of trauma, onset of trauma, cervical abnormalities, type of cervical spine lesion and ASIA impairment score. A prospective cohort study was performed to all patients with cervical spine injury treated inNeurosurgery Department of Dr. Hasan Sadikin Hospital Bandung that fullfiled the inclusion criteria. The subjects were classified based on age, sex, single/multiple trauma, acute /chronic, cervical abnormalities, complete/incomplete lesion and ASIA impairment score. The FIM examination was performed in Outpatient clinic of Neurosurgery. T-test and chi-square test was done to analyze the data. There were 17 cervical spine injury patients treated in Neurosurgery Department of Dr. Hasan Sadikin Hospital during April 2009–April 2010. The average FIM value of cervical spine injury in those patients is 4+ 1.63 by cohort prospective study. There were no correlation between FIM value with age, sex, type of trauma, onset of trauma and cervical abnormalities. Significant correlations were found between FIM value with type of cervical spine lesion and ASIA impairment score in cervical spine patients. Type of cervical spine lesion and ASIA impairment score have significant correlation with FIM value of patients in 6 months after cervical injury.

  7. Singular value correlation functions for products of Wishart random matrices

    International Nuclear Information System (INIS)

    Akemann, Gernot; Kieburg, Mario; Wei, Lu

    2013-01-01

    We consider the product of M quadratic random matrices with complex elements and no further symmetry, where all matrix elements of each factor have a Gaussian distribution. This generalizes the classical Wishart–Laguerre Gaussian unitary ensemble with M = 1. In this paper, we first compute the joint probability distribution for the singular values of the product matrix when the matrix size N and the number M are fixed but arbitrary. This leads to a determinantal point process which can be realized in two different ways. First, it can be written as a one-matrix singular value model with a non-standard Jacobian, or second, for M ⩾ 2, as a two-matrix singular value model with a set of auxiliary singular values and a weight proportional to the Meijer G-function. For both formulations, we determine all singular value correlation functions in terms of the kernels of biorthogonal polynomials which we explicitly construct. They are given in terms of the hypergeometric and Meijer G-functions, generalizing the Laguerre polynomials for M = 1. Our investigation was motivated from applications in telecommunication of multi-layered scattering multiple-input and multiple-output channels. We present the ergodic mutual information for finite-N for such a channel model with M − 1 layers of scatterers as an example. (paper)

  8. Work Socialization and Adolescents' Work-Related Values in Single-Mother African American Families

    Science.gov (United States)

    Toyokawa, Teru; McLoyd, Vonnie C.

    2013-01-01

    This study examined African American mothers' work socialization messages in relation to adolescents' work-related values. Moderation effects of mother-adolescent relation quality on the linkage between maternal socialization messages and adolescents' outcomes were also examined. Participants were 245 single African American mothers and their…

  9. Predictive value and construct validity of the work functioning screener-healthcare (WFS-H).

    Science.gov (United States)

    Boezeman, Edwin J; Nieuwenhuijsen, Karen; Sluiter, Judith K

    2016-05-25

    To test the predictive value and convergent construct validity of a 6-item work functioning screener (WFS-H). Healthcare workers (249 nurses) completed a questionnaire containing the work functioning screener (WFS-H) and a work functioning instrument (NWFQ) measuring the following: cognitive aspects of task execution and general incidents, avoidance behavior, conflicts and irritation with colleagues, impaired contact with patients and their family, and level of energy and motivation. Productivity and mental health were also measured. Negative and positive predictive values, AUC values, and sensitivity and specificity were calculated to examine the predictive value of the screener. Correlation analysis was used to examine the construct validity. The screener had good predictive value, since the results showed that a negative screener score is a strong indicator of work functioning not hindered by mental health problems (negative predictive values: 94%-98%; positive predictive values: 21%-36%; AUC:.64-.82; sensitivity: 42%-76%; and specificity 85%-87%). The screener has good construct validity due to moderate, but significant (ppredictive value and good construct validity. Its score offers occupational health professionals a helpful preliminary insight into the work functioning of healthcare workers.

  10. An extended set-value observer for position estimation using single range measurements

    DEFF Research Database (Denmark)

    Marcal, Jose; Jouffroy, Jerome; Fossen, Thor I.

    the observability of the system is briefly discussed and an extended set-valued observer is presented, with some discussion about the effect of the measurements noise on the final solution. This observer estimates bounds in the errors assuming that the exogenous signals are bounded, providing a safe region......The ability of estimating the position of an underwater vehicle from single range measurements is important in applications where one transducer marks an important geographical point, when there is a limitation in the size or cost of the vehicle, or when there is a failure in a system...... of transponders. The knowledge of the bearing of the vehicle and the range measurements from a single location can provide a solution which is sensitive to the trajectory that the vehicle is following, since there is no complete constraint on the position estimate with a single beacon. In this paper...

  11. Relevance of normative values for functional capacity evaluation

    NARCIS (Netherlands)

    Soer, R.; Van Der Schans, C.; Geertzen, J.; Groothoff, J.; Brouwer, Sandra; Dijkstra, P.; Reneman, M.

    2009-01-01

    Background: Functional Capacity Evaluations (FCEs) are evaluations designed to measure capacity to perform activities and are used to make recommendations for participation in work. Normative values of healthy working subjects' performances are unavailable, thus patients' performances cannot be

  12. Single or functionalized fullerenes interacting with heme group

    Energy Technology Data Exchange (ETDEWEB)

    Costa, Wallison Chaves; Diniz, Eduardo Moraes, E-mail: eduardo.diniz@ufma.br [Departamento de Física, Universidade Federal do Maranhão, Avenida dos Portugueses, 1966, CEP 65080-805, São Luís - MA (Brazil)

    2014-09-15

    The heme group is responsible for iron transportation through the bloodstream, where iron participates in redox reactions, electron transfer, gases detection etc. The efficiency of such processes can be reduced if the whole heme molecule or even the iron is somehow altered from its original oxidation state, which can be caused by interactions with nanoparticles as fullerenes. To verify how such particles alter the geometry and electronic structure of heme molecule, here we report first principles calculations based on density functional theory of heme group interacting with single C{sub 60} fullerene or with C{sub 60} functionalized with small functional groups (−CH{sub 3}, −COOH, −NH{sub 2}, −OH). The calculations shown that the system heme + nanoparticle has a different spin state in comparison with heme group if the fullerene is functionalized. Also a functional group can provide a stronger binding between nanoparticle and heme molecule or inhibit the chemical bonding in comparison with single fullerene results. In addition heme molecule loses electrons to the nanoparticles and some systems exhibited a geometry distortion in heme group, depending on the binding energy. Furthermore, one find that such nanoparticles induce a formation of spin up states in heme group. Moreover, there exist modifications in density of states near the Fermi energy. Although of such changes in heme electronic structure and geometry, the iron atom remains in the heme group with the same oxidation state, so that processes that involve the iron might not be affected, only those that depend on the whole heme molecule.

  13. Comparison of functional results of two fixation systems using single-row suturing of rotator cuff.

    Science.gov (United States)

    Muniesa-Herrero, M P; Torres-Campos, A; Urgel-Granados, A; Blanco-Llorca, J A; Floría-Arnal, L J; Roncal-Boj, J C; Castro-Sauras, A

    Arthroscopic repair of rotator cuff disorders is a technically demanding but successful procedure. Many anchor and suture alternatives are now available. The choice of the implant by the surgeon is less important than the configuration of the suture used to fix the tendon, however it is necessary to know if there are differences in the results, using each one of them. The aim of the study is to evaluate if there are differences between the knotted and non-knotted implant in terms of functional and satisfaction results. A retrospective study was carried out on 83 patients operated between 2010 and 2014 in our center using 2anchoring systems with and without knotting (39 versus 44 patients respectively), with single row in complete rupture of the rotator cuff. At the end of the follow-up, an average score was obtained on the Constant scale of 74.6 points. 98% of the patients considered the result of the surgery satisfactory. Statistically, there were no significant differences between the 2groups in terms of functionality, satisfaction or reincorporation to activities. The functional results of the single-row cuff suture are satisfactory, although biomechanical studies show advantages in favor of sutures that reproduce a transoseo system. It our series of patients the presence of knotting does not show per se a significant functional difference being both superimposable techniques in absolute values of functionality and patient satisfaction. Copyright © 2018 SECOT. Publicado por Elsevier España, S.L.U. All rights reserved.

  14. Semiclassical initial value treatment of wave functions

    International Nuclear Information System (INIS)

    Kay, Kenneth G.

    2010-01-01

    A semiclassical initial value approximation for time-independent wave functions, previously derived for integrable systems, is rederived in a form which allows it to be applied to more general systems. The wave function is expressed as an integral over a Lagrangian manifold that is constructed by propagating trajectories from an initial manifold formed on a Poincare surface. Even in the case of bound, integrable systems, it is unnecessary to identify action-angle variables or construct quantizing tori. The approximation is numerically tested for separable and highly chaotic two-dimensional quartic oscillator systems. For the separable (but highly anharmonic) system, the accuracy of the approximation is found to be excellent: overlaps of the semiclassical wave functions with the corresponding quantum wave functions exceed 0.999. For the chaotic system, semiclassical-quantum overlaps are found to range from 0.989 to 0.994, indicating accuracy that is still very good, despite the short classical trajectories used in the calculations.

  15. Longitudinal wave function control in single quantum dots with an applied magnetic field

    Science.gov (United States)

    Cao, Shuo; Tang, Jing; Gao, Yunan; Sun, Yue; Qiu, Kangsheng; Zhao, Yanhui; He, Min; Shi, Jin-An; Gu, Lin; Williams, David A.; Sheng, Weidong; Jin, Kuijuan; Xu, Xiulai

    2015-01-01

    Controlling single-particle wave functions in single semiconductor quantum dots is in demand to implement solid-state quantum information processing and spintronics. Normally, particle wave functions can be tuned transversely by an perpendicular magnetic field. We report a longitudinal wave function control in single quantum dots with a magnetic field. For a pure InAs quantum dot with a shape of pyramid or truncated pyramid, the hole wave function always occupies the base because of the less confinement at base, which induces a permanent dipole oriented from base to apex. With applying magnetic field along the base-apex direction, the hole wave function shrinks in the base plane. Because of the linear changing of the confinement for hole wave function from base to apex, the center of effective mass moves up during shrinking process. Due to the uniform confine potential for electrons, the center of effective mass of electrons does not move much, which results in a permanent dipole moment change and an inverted electron-hole alignment along the magnetic field direction. Manipulating the wave function longitudinally not only provides an alternative way to control the charge distribution with magnetic field but also a new method to tune electron-hole interaction in single quantum dots. PMID:25624018

  16. Longitudinal wave function control in single quantum dots with an applied magnetic field.

    Science.gov (United States)

    Cao, Shuo; Tang, Jing; Gao, Yunan; Sun, Yue; Qiu, Kangsheng; Zhao, Yanhui; He, Min; Shi, Jin-An; Gu, Lin; Williams, David A; Sheng, Weidong; Jin, Kuijuan; Xu, Xiulai

    2015-01-27

    Controlling single-particle wave functions in single semiconductor quantum dots is in demand to implement solid-state quantum information processing and spintronics. Normally, particle wave functions can be tuned transversely by an perpendicular magnetic field. We report a longitudinal wave function control in single quantum dots with a magnetic field. For a pure InAs quantum dot with a shape of pyramid or truncated pyramid, the hole wave function always occupies the base because of the less confinement at base, which induces a permanent dipole oriented from base to apex. With applying magnetic field along the base-apex direction, the hole wave function shrinks in the base plane. Because of the linear changing of the confinement for hole wave function from base to apex, the center of effective mass moves up during shrinking process. Due to the uniform confine potential for electrons, the center of effective mass of electrons does not move much, which results in a permanent dipole moment change and an inverted electron-hole alignment along the magnetic field direction. Manipulating the wave function longitudinally not only provides an alternative way to control the charge distribution with magnetic field but also a new method to tune electron-hole interaction in single quantum dots.

  17. Variational analysis of topological stationary barotropic MHD in the case of single-valued magnetic surfaces

    International Nuclear Information System (INIS)

    Yahalom, A

    2014-01-01

    Variational principles for magnetohydrodynamics have been introduced by previous authors both in Lagrangian and Eulerian form. Yahalom and Lynden-Bell (2008) have previously introduced simpler Eulerian variational principles from which all the relevant equations of barotropic magnetohydrodynamics can be derived. These variational principles were given in terms of six independent functions for non-stationary barotropic flows with given topologies and three independent functions for stationary barotropic flows. This is less then the seven variables which appear in the standard equations of barotropic magnetohydrodynamics which are the magnetic field B-vector the velocity field v-vector and the density ρ. Later, Yahalom (2010) introduced a simpler variational principle in terms of four functions for non-stationary barotropic magnetohydrodynamics. It was shown that the above variational principles are also relevant for flows of non-trivial topologies and in fact using those variational variables one arrives at additional topological conservation laws in terms of cuts of variables which have close resemblance to the Aharonov- Bohm phase (Yahalom (2013)). In previous examples (Yahalom and Lynden-Bell (2008); Yahalom (2013)) the magnetic field lines with non-trivial topology were at the intersection of two surface one of which was always multivalued; in this paper an example is introduced in which the magnetic helicity is not zero yet both surfaces are single-valued

  18. Predictive value and construct validity of the work functioning screener-healthcare (WFS-H)

    Science.gov (United States)

    Boezeman, Edwin J.; Nieuwenhuijsen, Karen; Sluiter, Judith K.

    2016-01-01

    Objectives: To test the predictive value and convergent construct validity of a 6-item work functioning screener (WFS-H). Methods: Healthcare workers (249 nurses) completed a questionnaire containing the work functioning screener (WFS-H) and a work functioning instrument (NWFQ) measuring the following: cognitive aspects of task execution and general incidents, avoidance behavior, conflicts and irritation with colleagues, impaired contact with patients and their family, and level of energy and motivation. Productivity and mental health were also measured. Negative and positive predictive values, AUC values, and sensitivity and specificity were calculated to examine the predictive value of the screener. Correlation analysis was used to examine the construct validity. Results: The screener had good predictive value, since the results showed that a negative screener score is a strong indicator of work functioning not hindered by mental health problems (negative predictive values: 94%-98%; positive predictive values: 21%-36%; AUC:.64-.82; sensitivity: 42%-76%; and specificity 85%-87%). The screener has good construct validity due to moderate, but significant (pvalue and good construct validity. Its score offers occupational health professionals a helpful preliminary insight into the work functioning of healthcare workers. PMID:27010085

  19. Camera functional scintiscanning of the kidneys - its significance and value for nuclear-medical renal diagnostics especially in comparison with isotope nephrography

    International Nuclear Information System (INIS)

    Wibmer, A.

    1982-01-01

    The thesis aimed at demonstrating the significance of functional scintiscanning in comparison with radioisotope nephrography and its informative value in individual kidney disease cases. To this end, 248 functional scintigrams of patients taken from various disease groups and 96 functional scintigrams of non-kidney-diseased persons were evaluated. As against nephrography, functional scintigraphic imaging has the advantage of displaying simultaneously both functional graphs and sequential scintigrams. This allows to asses the morphology, location and function of the non-functioning renal parenchyma and to localize and differentiate dysfunctions which are globally detectable in RIN, at a low patient exposure and within one single examination. ''Region-of-Interest'' selection in functional scintiscanning allows an exact demonstration of the kidneys which results in new normal values for the functional parameters. Owing to its case in handling and very low level of patient exposure, functional scintiscanning lends itself to an orientational examination of large patient groups, to an examination of severely ill patients without putting too much strain of them and to follow-up of all nephropathies. It even provides some information in renal insufficiency where other methods fail. However, functional scintiscanning appears to be inappropriate as a diagnostic method in inflammatory processes, hypertension and renal artery stenoses. (orig./MG) [de

  20. 12-month efficacy of a single radiofrequency ablation on autonomously functioning thyroid nodules.

    Science.gov (United States)

    Bernardi, Stella; Stacul, Fulvio; Michelli, Andrea; Giudici, Fabiola; Zuolo, Giulia; de Manzini, Nicolò; Dobrinja, Chiara; Zanconati, Fabrizio; Fabris, Bruno

    2017-09-01

    Radiofrequency ablation has been advocated as an alternative to radioiodine and/or surgery for the treatment of autonomously functioning benign thyroid nodules. However, only a few studies have measured radiofrequency ablation efficacy on autonomously functioning benign thyroid nodules. The aim of this work was to evaluate the 12-month efficacy of a single session of radiofrequency ablation (performed with the moving shot technique) on solitary autonomously functioning benign thyroid nodules. Thirty patients with a single, benign autonomously functioning benign thyroid nodules, who were either unwilling or ineligible to undergo surgery and radioiodine, were treated with radiofrequency ablation between April 2012 and May 2015. All the patients underwent a single radiofrequency ablation, performed with the 18-gauge needle and the moving shot technique. Clinical, laboratory, and ultrasound evaluations were scheduled at baseline, and after 1, 3, 6, and 12 months from the procedure. A single radiofrequency ablation reduced thyroid nodule volume by 51, 63, 69, and 75 % after 1, 3, 6, and 12 months, respectively. This was associated with a significant improvement of local cervical discomfort and cosmetic score. As for thyroid function, 33 % of the patients went into remission after 3 months, 43 % after 6 months, and 50 % after 12 months from the procedure. This study demonstrates that a single radiofrequency ablation allowed us to withdraw anti-thyroid medication in 50 % of the patients, who remained euthyroid afterwards. This study shows that a single radiofrequency ablation was effective in 50 % of patients with autonomously functioning benign thyroid nodules. Patients responded gradually to the treatment. It is possible that longer follow-up studies might show greater response rates.

  1. The value of the abdominal radiograph in children with functional gastrointestinal disorders

    Energy Technology Data Exchange (ETDEWEB)

    Bongers, Marloes E.J. [Department of Pediatric Gastroenterology and Nutrition, Academic Medical Centre, Meibergdreef 9, 1105 AZ Amsterdam (Netherlands)]. E-mail: mbongers@uva.amc.nl; Voskuijl, Wieger P. [Department of Pediatric Gastroenterology and Nutrition, Academic Medical Centre, Meibergdreef 9, 1105 AZ Amsterdam (Netherlands); Rijn, Rick R. van [Department of Pediatric Radiology, Emma Children' s Hospital/Academic Medical Centre, Meibergdreef 9, 1105 AZ Amsterdam (Netherlands); Benninga, Marc A. [Department of Pediatric Gastroenterology and Nutrition, Academic Medical Centre, Meibergdreef 9, 1105 AZ Amsterdam (Netherlands)

    2006-07-15

    Functional gastrointestinal disorder is a common problem in childhood. The symptoms vary from a relative mild gastrointestinal problem such as abdominal pain or infrequent defecation to severe problems with fecal impaction and fecal incontinence. The aim of this review is to describe and evaluate the value of the different existing methods to assess fecal loading on an abdominal radiograph with or without the use of radio-opaque markers in the diagnosis of functional abdominal pain, functional constipation and functional non-retentive fecal incontinence. In our opinion, the abdominal radiograph has limited value in the diagnostic work-up of children with functional gastrointestinal disorders.

  2. The value of the abdominal radiograph in children with functional gastrointestinal disorders

    International Nuclear Information System (INIS)

    Bongers, Marloes E.J.; Voskuijl, Wieger P.; Rijn, Rick R. van; Benninga, Marc A.

    2006-01-01

    Functional gastrointestinal disorder is a common problem in childhood. The symptoms vary from a relative mild gastrointestinal problem such as abdominal pain or infrequent defecation to severe problems with fecal impaction and fecal incontinence. The aim of this review is to describe and evaluate the value of the different existing methods to assess fecal loading on an abdominal radiograph with or without the use of radio-opaque markers in the diagnosis of functional abdominal pain, functional constipation and functional non-retentive fecal incontinence. In our opinion, the abdominal radiograph has limited value in the diagnostic work-up of children with functional gastrointestinal disorders

  3. Computation of Value Functions in Nonlinear Differential Games with State Constraints

    KAUST Repository

    Botkin, Nikolai

    2013-01-01

    Finite-difference schemes for the computation of value functions of nonlinear differential games with non-terminal payoff functional and state constraints are proposed. The solution method is based on the fact that the value function is a generalized viscosity solution of the corresponding Hamilton-Jacobi-Bellman-Isaacs equation. Such a viscosity solution is defined as a function satisfying differential inequalities introduced by M. G. Crandall and P. L. Lions. The difference with the classical case is that these inequalities hold on an unknown in advance subset of the state space. The convergence rate of the numerical schemes is given. Numerical solution to a non-trivial three-dimensional example is presented. © 2013 IFIP International Federation for Information Processing.

  4. Model tests and numerical analyses on horizontal impedance functions of inclined single piles embedded in cohesionless soil

    Science.gov (United States)

    Goit, Chandra Shekhar; Saitoh, Masato

    2013-03-01

    Horizontal impedance functions of inclined single piles are measured experimentally for model soil-pile systems with both the effects of local soil nonlinearity and resonant characteristics. Two practical pile inclinations of 5° and 10° in addition to a vertical pile embedded in cohesionless soil and subjected to lateral harmonic pile head loadings for a wide range of frequencies are considered. Results obtained with low-to-high amplitude of lateral loadings on model soil-pile systems encased in a laminar shear box show that the local nonlinearities have a profound impact on the horizontal impedance functions of piles. Horizontal impedance functions of inclined piles are found to be smaller than the vertical pile and the values decrease as the angle of pile inclination increases. Distinct values of horizontal impedance functions are obtained for the `positive' and `negative' cycles of harmonic loadings, leading to asymmetric force-displacement relationships for the inclined piles. Validation of these experimental results is carried out through three-dimensional nonlinear finite element analyses, and the results from the numerical models are in good agreement with the experimental data. Sensitivity analyses conducted on the numerical models suggest that the consideration of local nonlinearity at the vicinity of the soil-pile interface influence the response of the soil-pile systems.

  5. Wiener-Hopf factorization of piecewise meromorphic matrix-valued functions

    International Nuclear Information System (INIS)

    Adukov, Victor M

    2009-01-01

    Let D + be a multiply connected domain bounded by a contour Γ, let D - be the complement of D + union Γ in C-bar=C union {∞}, and a(t) be a continuous invertible matrix-valued function on Γ which can be meromorphically extended into the open disconnected set D - (as a piecewise meromorphic matrix-valued function). An explicit solution of the Wiener-Hopf factorization problem for a(t) is obtained and the partial factorization indices of a(t) are calculated. Here an explicit solution of a factorization problem is meant in the sense of reducing it to the investigation of finitely many systems of linear algebraic equations with matrices expressed in closed form, that is, in quadratures. Bibliography: 15 titles.

  6. Ultrafast time measurements by time-correlated single photon counting coupled with superconducting single photon detector

    Energy Technology Data Exchange (ETDEWEB)

    Shcheslavskiy, V., E-mail: vis@becker-hickl.de; Becker, W. [Becker & Hickl GmbH, Nahmitzer Damm 30, 12277 Berlin (Germany); Morozov, P.; Divochiy, A. [Scontel, Rossolimo St., 5/22-1, Moscow 119021 (Russian Federation); Vakhtomin, Yu. [Scontel, Rossolimo St., 5/22-1, Moscow 119021 (Russian Federation); Moscow State Pedagogical University, 1/1 M. Pirogovskaya St., Moscow 119991 (Russian Federation); Smirnov, K. [Scontel, Rossolimo St., 5/22-1, Moscow 119021 (Russian Federation); Moscow State Pedagogical University, 1/1 M. Pirogovskaya St., Moscow 119991 (Russian Federation); National Research University Higher School of Economics, 20 Myasnitskaya St., Moscow 101000 (Russian Federation)

    2016-05-15

    Time resolution is one of the main characteristics of the single photon detectors besides quantum efficiency and dark count rate. We demonstrate here an ultrafast time-correlated single photon counting (TCSPC) setup consisting of a newly developed single photon counting board SPC-150NX and a superconducting NbN single photon detector with a sensitive area of 7 × 7 μm. The combination delivers a record instrument response function with a full width at half maximum of 17.8 ps and system quantum efficiency ∼15% at wavelength of 1560 nm. A calculation of the root mean square value of the timing jitter for channels with counts more than 1% of the peak value yielded about 7.6 ps. The setup has also good timing stability of the detector–TCSPC board.

  7. Density functional theory study of bulk and single-layer magnetic semiconductor CrPS4

    Science.gov (United States)

    Zhuang, Houlong L.; Zhou, Jia

    2016-11-01

    Searching for two-dimensional (2D) materials with multifunctionality is one of the main goals of current research in 2D materials. Magnetism and semiconducting are certainly two desirable functional properties for a single 2D material. In line with this goal, here we report a density functional theory (DFT) study of bulk and single-layer magnetic semiconductor CrPS4. We find that the ground-state magnetic structure of bulk CrPS4 exhibits the A-type antiferromagnetic ordering, which transforms to ferromagnetic (FM) ordering in single-layer CrPS4. The calculated formation energy and phonon spectrum confirm the stability of single-layer CrPS4. The band gaps of FM single-layer CrPS4 calculated with a hybrid density functional are within the visible-light range. We also study the effects of FM ordering on the optical absorption spectra and band alignments for water splitting, indicating that single-layer CrPS4 could be a potential photocatalyst. Our work opens up ample opportunities of energy-related applications of single-layer CrPS4.

  8. Arithmetical Fourier and Limit values of elliptic modular functions

    Indian Academy of Sciences (India)

    2

    In order to remove singularities, Riemann used a well-known device of taking the odd part (3.2) or an alternate sum (3.3) to be stated in §3. In §2 of this note we shall reveal that the limit values of elliptic modular functions in Riemann's fragment II evaluated by the differences of polyloga- rithm function l1(x) of order 1 (cf.

  9. Single-wavelength functional photoacoustic microscopy in biological tissue.

    Science.gov (United States)

    Danielli, Amos; Favazza, Christopher P; Maslov, Konstantin; Wang, Lihong V

    2011-03-01

    Recently, we developed a reflection-mode relaxation photoacoustic microscope, based on saturation intensity, to measure picosecond relaxation times using a nanosecond laser. Here, using the different relaxation times of oxygenated and deoxygenated hemoglobin molecules, both possessing extremely low fluorescence quantum yields, the oxygen saturation was quantified in vivo with single-wavelength photoacoustic microscopy. All previous functional photoacoustic microscopy measurements required imaging with multiple-laser-wavelength measurements to quantify oxygen saturation. Eliminating the need for multiwavelength measurements removes the influence of spectral properties on oxygenation calculations and improves the portability and cost-effectiveness of functional or molecular photoacoustic microscopy.

  10. Single Fluorescent Molecules as Nano-Illuminators for Biological Structure and Function

    Science.gov (United States)

    Moerner, W. E.

    2011-03-01

    Since the first optical detection and spectroscopy of a single molecule in a solid (Phys. Rev. Lett. {62}, 2535 (1989)), much has been learned about the ability of single molecules to probe local nanoenvironments and individual behavior in biological and nonbiological materials in the absence of ensemble averaging that can obscure heterogeneity. Because each single fluorophore acts a light source roughly 1 nm in size, microscopic imaging of individual fluorophores leads naturally to superlocalization, or determination of the position of the molecule with precision beyond the optical diffraction limit, simply by digitization of the point-spread function from the single emitter. For example, the shape of single filaments in a living cell can be extracted simply by allowing a single molecule to move through the filament (PNAS {103}, 10929 (2006)). The addition of photoinduced control of single-molecule emission allows imaging beyond the diffraction limit (super-resolution) and a new array of acronyms (PALM, STORM, F-PALM etc.) and advances have appeared. We have used the native blinking and switching of a common yellow-emitting variant of green fluorescent protein (EYFP) reported more than a decade ago (Nature {388}, 355 (1997)) to achieve sub-40 nm super-resolution imaging of several protein structures in the bacterium Caulobacter crescentus: the quasi-helix of the actin-like protein MreB (Nat. Meth. {5}, 947 (2008)), the cellular distribution of the DNA binding protein HU (submitted), and the recently discovered division spindle composed of ParA filaments (Nat. Cell Biol. {12}, 791 (2010)). Even with these advances, better emitters would provide more photons and improved resolution, and a new photoactivatable small-molecule emitter has recently been synthesized and targeted to specific structures in living cells to provide super-resolution images (JACS {132}, 15099 (2010)). Finally, a new optical method for extracting three-dimensional position information based on

  11. A Generalized Analytic Operator-Valued Function Space Integral and a Related Integral Equation

    International Nuclear Information System (INIS)

    Chang, K.S.; Kim, B.S.; Park, C.H.; Ryu, K.S.

    2003-01-01

    We introduce a generalized Wiener measure associated with a Gaussian Markov process and define a generalized analytic operator-valued function space integral as a bounded linear operator from L p into L p-ci r cumflexprime (1< p ≤ 2) by the analytic continuation of the generalized Wiener integral. We prove the existence of the integral for certain functionals which involve some Borel measures. Also we show that the generalized analytic operator-valued function space integral satisfies an integral equation related to the generalized Schroedinger equation. The resulting theorems extend the theory of operator-valued function space integrals substantially and previous theorems about these integrals are generalized by our results

  12. Single-wavelength functional photoacoustic microscopy in biological tissue

    OpenAIRE

    Danielli, Amos; Favazza, Christopher P.; Maslov, Konstantin; Wang, Lihong V.

    2011-01-01

    Recently, we developed a reflection-mode relaxation photoacoustic microscope, based on saturation intensity, to measure picosecond relaxation times using a nanosecond laser. Here, using the different relaxation times of oxygenated and deoxygenated hemoglobin molecules, both possessing extremely low fluorescence quantum yields, the oxygen saturation was quantified in vivo with single-wavelength photoacoustic microscopy. All previous functional photoacoustic microscopy measurements required ima...

  13. Functionalization of gold and nanocrystalline diamond atomic force microscope tips for single molecule force spectroscopy

    Science.gov (United States)

    Drew, Michael E.

    The atomic force microscope (AFM) has fueled interest in nanotechnology because of its ability to image surfaces at the nanometer level and act as a molecular force sensor. Functionalization of the surface of an AFM tip surface in a stable, controlled manner expands the capabilities of the AFM and enables additional applications in the fields of single molecule force spectroscopy and nanolithography. Two AFM tip functionalizations are described: the assembly of tripodal molecular tips onto gold AFM tips and the photochemical attachment of terminal alkenes to nanocrystalline diamond (NCD) AFM tips. Two separate tripodal molecules with different linker lengths and a monopodal molecule terminated with biotin were synthesized to attach to a gold AFM tip for single molecule force spectroscopy. The immobilization of these molecules was examined by contact angle measurements, spectroscopic ellipsometry, infrared, and near edge x-ray absorption fine structure (NEXAFS) spectroscopy. All three molecules displayed rupture forces that agreed with previously reported values for the biotin--avidin rupture. The tripodal molecular tip displayed narrower distribution in their force histograms than the monopodal molecular tip. The performance of the tripodal molecular tip was compared to the monopodal molecular tip in single molecule force spectroscopy studies. Over repeated measurements, the distribution of forces for the monopodal molecular tip shifted to lower forces, whereas the distribution for the tripodal molecular tip remained constant throughout. Loading rate dependence and control experiments further indicated that the rupture forces of the tripod molecular tips were specific to the biotin--NeutrAvidin interaction. The second functionalization method used the photochemical attachment of undecylenic acid to NCD AFM tips. The photochemical attachment of undecylenic acid to hydrogen-terminated NCD wafer surfaces was investigated by contact angle measurements, x

  14. The Dedekind completion of C ( X ): an interval-valued functions ...

    African Journals Online (AJOL)

    In his paper [1] R. Anguelov described the construction of the Dedekind order completion of C(X) the set of all real-valued continuous functions defined on a completely regular topological space X; using Hausdorff continuous real intervalvalued functions. The aim of this paper is to show that Anguelov's construction can be ...

  15. Nodal structure and phase shifts of zero-incident-energy wave functions: Multiparticle single-channel scattering

    International Nuclear Information System (INIS)

    Iwinski, Z.R.; Rosenberg, L.; Spruch, L.

    1986-01-01

    For potential scattering, with delta/sub L/(k) the phase shift modulo π for an incident wave number k, Levinson's theorem gives delta/sub L/(0)-delta/sub L/(infinity) in terms of N/sub L/, the number of bound states of angular momentum L, for delta/sub L/(k) assumed to be a continuous function of k. N/sub L/ also determines the number of nodes of the zero-energy wave function u/sub L/(r). A knowledge of the nodal structure and of the absolute value of delta/sub L/(0) is very useful in theoretical studies of low-energy potential scattering. Two preliminary attempts, one formal and one ''physical,'' are made to extend the above results to single-channel scattering by a compound system initially in its ground state. The nodal structure will be of greater interest to us here than an extension of Levinson's theorem

  16. A single model procedure for tank calibration function estimation

    International Nuclear Information System (INIS)

    York, J.C.; Liebetrau, A.M.

    1995-01-01

    Reliable tank calibrations are a vital component of any measurement control and accountability program for bulk materials in a nuclear reprocessing facility. Tank volume calibration functions used in nuclear materials safeguards and accountability programs are typically constructed from several segments, each of which is estimated independently. Ideally, the segments correspond to structural features in the tank. In this paper the authors use an extension of the Thomas-Liebetrau model to estimate the entire calibration function in a single step. This procedure automatically takes significant run-to-run differences into account and yields an estimate of the entire calibration function in one operation. As with other procedures, the first step is to define suitable calibration segments. Next, a polynomial of low degree is specified for each segment. In contrast with the conventional practice of constructing a separate model for each segment, this information is used to set up the design matrix for a single model that encompasses all of the calibration data. Estimation of the model parameters is then done using conventional statistical methods. The method described here has several advantages over traditional methods. First, modeled run-to-run differences can be taken into account automatically at the estimation step. Second, no interpolation is required between successive segments. Third, variance estimates are based on all the data, rather than that from a single segment, with the result that discontinuities in confidence intervals at segment boundaries are eliminated. Fourth, the restrictive assumption of the Thomas-Liebetrau method, that the measured volumes be the same for all runs, is not required. Finally, the proposed methods are readily implemented using standard statistical procedures and widely-used software packages

  17. Inverse electronic scattering by Green's functions and singular values decomposition

    International Nuclear Information System (INIS)

    Mayer, A.; Vigneron, J.-P.

    2000-01-01

    An inverse scattering technique is developed to enable a sample reconstruction from the diffraction figures obtained by electronic projection microscopy. In its Green's functions formulation, this technique takes account of all orders of diffraction by performing an iterative reconstruction of the wave function on the observation screen. This scattered wave function is then backpropagated to the sample to determine the potential-energy distribution, which is assumed real valued. The method relies on the use of singular values decomposition techniques, thus providing the best least-squares solutions and enabling a reduction of noise. The technique is applied to the analysis of a two-dimensional nanometric sample that is observed in Fresnel conditions with an electronic energy of 25 eV. The algorithm turns out to provide results with a mean relative error of the order of 5% and to be very stable against random noise

  18. Generalized Functional Linear Models With Semiparametric Single-Index Interactions

    KAUST Repository

    Li, Yehua

    2010-06-01

    We introduce a new class of functional generalized linear models, where the response is a scalar and some of the covariates are functional. We assume that the response depends on multiple covariates, a finite number of latent features in the functional predictor, and interaction between the two. To achieve parsimony, the interaction between the multiple covariates and the functional predictor is modeled semiparametrically with a single-index structure. We propose a two step estimation procedure based on local estimating equations, and investigate two situations: (a) when the basis functions are pre-determined, e.g., Fourier or wavelet basis functions and the functional features of interest are known; and (b) when the basis functions are data driven, such as with functional principal components. Asymptotic properties are developed. Notably, we show that when the functional features are data driven, the parameter estimates have an increased asymptotic variance, due to the estimation error of the basis functions. Our methods are illustrated with a simulation study and applied to an empirical data set, where a previously unknown interaction is detected. Technical proofs of our theoretical results are provided in the online supplemental materials.

  19. Generalized Functional Linear Models With Semiparametric Single-Index Interactions

    KAUST Repository

    Li, Yehua; Wang, Naisyin; Carroll, Raymond J.

    2010-01-01

    We introduce a new class of functional generalized linear models, where the response is a scalar and some of the covariates are functional. We assume that the response depends on multiple covariates, a finite number of latent features in the functional predictor, and interaction between the two. To achieve parsimony, the interaction between the multiple covariates and the functional predictor is modeled semiparametrically with a single-index structure. We propose a two step estimation procedure based on local estimating equations, and investigate two situations: (a) when the basis functions are pre-determined, e.g., Fourier or wavelet basis functions and the functional features of interest are known; and (b) when the basis functions are data driven, such as with functional principal components. Asymptotic properties are developed. Notably, we show that when the functional features are data driven, the parameter estimates have an increased asymptotic variance, due to the estimation error of the basis functions. Our methods are illustrated with a simulation study and applied to an empirical data set, where a previously unknown interaction is detected. Technical proofs of our theoretical results are provided in the online supplemental materials.

  20. Transient impairments in single muscle fibre contractile function after prolonged cycling in elite endurance athletes

    DEFF Research Database (Denmark)

    Hvid, L G; Gejl, Kasper Degn; Bech, R D

    2013-01-01

    Prolonged muscle activity impairs whole-muscle performance and function. However, little is known about the effects of prolonged muscle activity on the contractile function of human single muscle fibres. The purpose of this study was to investigate the effects of prolonged exercise and subsequent...... recovery on the contractile function of single muscle fibres obtained from elite athletes....

  1. Single-Molecule Transport at a Rectifying GaAs Contact.

    Science.gov (United States)

    Vezzoli, Andrea; Brooke, Richard J; Ferri, Nicolò; Higgins, Simon J; Schwarzacher, Walther; Nichols, Richard J

    2017-02-08

    In most single- or few-molecule devices, the contact electrodes are simple ohmic resistors. Here we describe a new type of single-molecule device in which metal and semiconductor contact electrodes impart a function, namely, current rectification, which is then modified by a molecule bridging the gap. We study junctions with the structure Au STM tip/X/n-GaAs substrate, where "X" is either a simple alkanedithiol or a conjugated unit bearing thiol/methylthiol contacts, and we detect current jumps corresponding to the attachment and detachment of single molecules. From the magnitudes of the current jumps we can deduce values for the conductance decay constant with molecule length that agree well with values determined from Au/molecule/Au junctions. The ability to impart functionality to a single-molecule device through the properties of the contacts as well as through the properties of the molecule represents a significant extension of the single-molecule electronics "tool-box".

  2. Shedding Light on Protein Folding, Structural and Functional Dynamics by Single Molecule Studies

    Directory of Open Access Journals (Sweden)

    Krutika Bavishi

    2014-11-01

    Full Text Available The advent of advanced single molecule measurements unveiled a great wealth of dynamic information revolutionizing our understanding of protein dynamics and behavior in ways unattainable by conventional bulk assays. Equipped with the ability to record distribution of behaviors rather than the mean property of a population, single molecule measurements offer observation and quantification of the abundance, lifetime and function of multiple protein states. They also permit the direct observation of the transient and rarely populated intermediates in the energy landscape that are typically averaged out in non-synchronized ensemble measurements. Single molecule studies have thus provided novel insights about how the dynamic sampling of the free energy landscape dictates all aspects of protein behavior; from its folding to function. Here we will survey some of the state of the art contributions in deciphering mechanisms that underlie protein folding, structural and functional dynamics by single molecule fluorescence microscopy techniques. We will discuss a few selected examples highlighting the power of the emerging techniques and finally discuss the future improvements and directions.

  3. Computing the Kummer function $U(a,b,z)$ for small values of the arguments

    NARCIS (Netherlands)

    A. Gil (Amparo); J. Segura (Javier); N.M. Temme (Nico)

    2015-01-01

    textabstractWe describe methods for computing the Kummer function $U(a,b,z)$ for small values of $z$, with special attention to small values of $b$. For these values of $b$ the connection formula that represents $U(a,b,z)$ as a linear combination of two ${}_1F_1$-functions needs a limiting

  4. The value of identity: olfactory notes on orbitofrontal cortex function.

    Science.gov (United States)

    Gottfried, Jay A; Zelano, Christina

    2011-12-01

    Neuroscientific research has emphatically promoted the idea that the key function of the orbitofrontal cortex (OFC) is to encode value. Associative learning studies indicate that OFC representations of stimulus cues reflect the predictive value of expected outcomes. Neuroeconomic studies suggest that the OFC distills abstract representations of value from discrete commodities to optimize choice. Although value-based models provide good explanatory power for many different findings, these models are typically disconnected from the very stimuli and commodities giving rise to those value representations. Little provision is made, either theoretically or empirically, for the necessary cooperative role of object identity, without which value becomes orphaned from its source. As a step toward remediating the value of identity, this review provides a focused olfactory survey of OFC research, including new work from our lab, to highlight the elemental involvement of this region in stimulus-specific predictive coding of both perceptual outcomes and expected values. © 2011 New York Academy of Sciences.

  5. Tunable complex-valued multi-tap microwave photonic filter based on single silicon-oninsulator microring resonator

    DEFF Research Database (Denmark)

    Lloret, Juan; Sancho, Juan; Pu, Minhao

    2011-01-01

    A complex-valued multi-tap tunable microwave photonic filter based on single silicon-on-insulator microring resonator is presented. The degree of tunability of the approach involving two, three and four taps is theoretical and experimentally characterized, respectively. The constraints of exploit...

  6. Satisfactory knee function after single-stage posterolateral corner reconstruction in the multi-ligament injured/dislocated knee using the anatomic single-graft technique.

    Science.gov (United States)

    Sanders, Thomas L; Johnson, Nick R; Pareek, Ayoosh; Krych, Aaron J; Marx, Robert G; Stuart, Michael J; Levy, Bruce A

    2018-04-01

    Increasing importance has been placed on the posterolateral corner (PLC) in maintaining varus and rotational stability of the knee. The goal of this study was to evaluate knee function and clinical stability following a single-graft PLC reconstruction technique and identify factors associated with poor knee function. This study identified patients with a multi-ligament knee injury between 2006 and 2013. Patients who received a single-graft fibular collateral ligament and PLC reconstruction with a single-stage surgery during the study period and had a minimum follow-up of 2 years after surgery were included. Functional outcomes were assessed using Lysholm and IKDC scores. Varus and rotational knee laxity and range of motion were assessed using physical examination. The final study cohort included 61 patients who underwent PLC reconstruction using a single-graft technique. The mean IKDC score was 74.1 (± 22.3) and the mean Lysholm score was 80.3 (± 21.8) at mean follow-up of 3.8 years (range 2-9 years). Mean range of motion at final follow-up measured from 0° to 126° [range flexion: 95-145, range extension: 0-5]. Fifty-eight patients (95%) had grade 0 varus laxity in full knee extension, and 54 patients (88.5%) had grade 0 varus laxity at 30° of knee flexion. Female gender was associated with a lower postoperative IKDC score (p = 0.04). Surgical treatment of the PLC using a single-graft technique can result in satisfactory knee function and stable physical examination findings at minimum 2 years after surgery. Female gender was predictive of poor knee function after PLC reconstruction. Surgical treatment of PLC injuries should be individualized based on the timing of surgery, specific injured knee structures, and physical examination findings. This study helps validate the use of a single-graft technique for PLC reconstruction and can be used to help counsel patients about expected knee function after surgical treatment of PLC injuries. Level of evidence

  7. Functional magnetic resonance microscopy at single-cell resolution in Aplysia californica

    Science.gov (United States)

    Radecki, Guillaume; Nargeot, Romuald; Jelescu, Ileana Ozana; Le Bihan, Denis; Ciobanu, Luisa

    2014-01-01

    In this work, we show the feasibility of performing functional MRI studies with single-cell resolution. At ultrahigh magnetic field, manganese-enhanced magnetic resonance microscopy allows the identification of most motor neurons in the buccal network of Aplysia at low, nontoxic Mn2+ concentrations. We establish that Mn2+ accumulates intracellularly on injection into the living Aplysia and that its concentration increases when the animals are presented with a sensory stimulus. We also show that we can distinguish between neuronal activities elicited by different types of stimuli. This method opens up a new avenue into probing the functional organization and plasticity of neuronal networks involved in goal-directed behaviors with single-cell resolution. PMID:24872449

  8. Injection molded nanofluidic chips: Fabrication method and functional tests using single-molecule DNA experiments

    DEFF Research Database (Denmark)

    Utko, Pawel; Persson, Karl Fredrik; Kristensen, Anders

    2011-01-01

    We demonstrate that fabrication of nanofluidic systems can be greatly simplified by injection molding of polymers. We functionally test our devices by single-molecule DNA experiments in nanochannels.......We demonstrate that fabrication of nanofluidic systems can be greatly simplified by injection molding of polymers. We functionally test our devices by single-molecule DNA experiments in nanochannels....

  9. An Interval-Valued Intuitionistic Fuzzy TOPSIS Method Based on an Improved Score Function

    Directory of Open Access Journals (Sweden)

    Zhi-yong Bai

    2013-01-01

    Full Text Available This paper proposes an improved score function for the effective ranking order of interval-valued intuitionistic fuzzy sets (IVIFSs and an interval-valued intuitionistic fuzzy TOPSIS method based on the score function to solve multicriteria decision-making problems in which all the preference information provided by decision-makers is expressed as interval-valued intuitionistic fuzzy decision matrices where each of the elements is characterized by IVIFS value and the information about criterion weights is known. We apply the proposed score function to calculate the separation measures of each alternative from the positive and negative ideal solutions to determine the relative closeness coefficients. According to the values of the closeness coefficients, the alternatives can be ranked and the most desirable one(s can be selected in the decision-making process. Finally, two illustrative examples for multicriteria fuzzy decision-making problems of alternatives are used as a demonstration of the applications and the effectiveness of the proposed decision-making method.

  10. Multi-point boundary value problems for linear functional-differential equations

    Czech Academy of Sciences Publication Activity Database

    Domoshnitsky, A.; Hakl, Robert; Půža, Bedřich

    2017-01-01

    Roč. 24, č. 2 (2017), s. 193-206 ISSN 1072-947X Institutional support: RVO:67985840 Keywords : boundary value problems * linear functional-differential equations * functional-differential inequalities Subject RIV: BA - General Mathematics OBOR OECD: Applied mathematics Impact factor: 0.290, year: 2016 https://www.degruyter.com/view/j/gmj.2017.24.issue-2/gmj-2016-0076/gmj-2016-0076. xml

  11. Multi-point boundary value problems for linear functional-differential equations

    Czech Academy of Sciences Publication Activity Database

    Domoshnitsky, A.; Hakl, Robert; Půža, Bedřich

    2017-01-01

    Roč. 24, č. 2 (2017), s. 193-206 ISSN 1072-947X Institutional support: RVO:67985840 Keywords : boundary value problems * linear functional- differential equations * functional- differential inequalities Subject RIV: BA - General Mathematics OBOR OECD: Applied mathematics Impact factor: 0.290, year: 2016 https://www.degruyter.com/view/j/gmj.2017.24.issue-2/gmj-2016-0076/gmj-2016-0076.xml

  12. Single gold nanoparticle plasmonic spectroscopy for study of chemical-dependent efflux function of single ABC transporters of single live Bacillus subtilis cells.

    Science.gov (United States)

    Browning, Lauren M; Lee, Kerry J; Cherukuri, Pavan K; Huang, Tao; Songkiatisak, Preeyaporn; Warren, Seth; Xu, Xiao-Hong Nancy

    2018-03-26

    ATP-binding cassette (ABC) membrane transporters serve as self-defense transport apparatus in many living organisms and they can selectively extrude a wide variety of substrates, leading to multidrug resistance (MDR). The detailed molecular mechanisms remain elusive. Single nanoparticle plasmonic spectroscopy highly depends upon their sizes, shapes, chemical and surface properties. In our previous studies, we have used the size-dependent plasmonic spectra of single silver nanoparticles (Ag NPs) to study the real-time efflux kinetics of the ABC (BmrA) transporter and MexAB-OprM transporter in single live cells (Gram-positive and Gram-negative bacterium), respectively. In this study, we prepared and used purified, biocompatible and stable (non-aggregated) gold nanoparticles (Au NPs) (12.4 ± 0.9 nm) to study the efflux kinetics of single BmrA membrane transporters of single live Bacillus subtillis cells, aiming to probe chemical dependent efflux functions of BmrA transporters and their potential chemical sensing capability. Similar to those observed using Ag NPs, accumulation of the intracellular Au NPs in single live cells (WT and ΔBmrA) highly depends upon the cellular expression of BmrA and the NP concentration (0.7 and 1.4 nM). The lower accumulation of intracellular Au NPs in WT (normal expression of BmrA) than ΔBmrA (deletion of bmrA) indicates that BmrA extrudes the Au NPs out of the WT cells. The accumulation of Au NPs in the cells increases with NP concentration, suggesting that the Au NPs most likely passively diffuse into the cells, similar to antibiotics. The result demonstrates that such small Au NPs can serve as imaging probes to study the efflux function of the BmrA membrane transporter in single live cells. Furthermore, the dependence of the accumulation rate of intracellular Au NPs in single live cells upon the expression of BmrA and the concentration of the NPs is about twice higher than that of the same sized Ag NPs. This interesting finding

  13. Boundary value problems of holomorphic vector functions in 1D QCs

    International Nuclear Information System (INIS)

    Gao Yang; Zhao Yingtao; Zhao Baosheng

    2007-01-01

    By means of the generalized Stroh formalism, two-dimensional (2D) problems of one-dimensional (1D) quasicrystals (QCs) elasticity are turned into the boundary value problems of holomorphic vector functions in a given region. If the conformal mapping from an ellipse to a circle is known, a general method for solving the boundary value problems of holomorphic vector functions can be presented. To illustrate its utility, by using the necessary and sufficient condition of boundary value problems of holomorphic vector functions, we consider two basic 2D problems in 1D QCs, that is, an elliptic hole and a rigid line inclusion subjected to uniform loading at infinity. For the crack problem, the intensity factors of phonon and phason fields are determined, and the physical sense of the results relative to phason and the difference between mechanical behaviors of the crack problem in crystals and QCs are figured out. Moreover, the same procedure can be used to deal with the elastic problems for 2D and three-dimensional (3D) QCs

  14. Topological characteristics of multi-valued maps and Lipschitzian functionals

    International Nuclear Information System (INIS)

    Klimov, V S

    2008-01-01

    This paper deals with the operator inclusion O element of F(x)+N Q (x), where F is a multi-valued map of monotonic type from a reflexive space V to its conjugate V * and N Q is the cone normal to the closed set Q, which, generally speaking, is not convex. To estimate the number of solutions of this inclusion we introduce topological characteristics of multi-valued maps and Lipschitzian functionals that have the properties of additivity and homotopy invariance. We prove some infinite-dimensional versions of the Poincare-Hopf theorem

  15. Fluidic Logic Used in a Systems Approach to Enable Integrated Single-cell Functional Analysis

    Directory of Open Access Journals (Sweden)

    Naveen Ramalingam

    2016-09-01

    Full Text Available The study of single cells has evolved over the past several years to include expression and genomic analysis of an increasing number of single cells. Several studies have demonstrated wide-spread variation and heterogeneity within cell populations of similar phenotype. While the characterization of these populations will likely set the foundation for our understanding of genomic- and expression-based diversity, it will not be able to link the functional differences of a single cell to its underlying genomic structure and activity. Currently, it is difficult to perturb single cells in a controlled environment, monitor and measure the response due to perturbation, and link these response measurements to downstream genomic and transcriptomic analysis. In order to address this challenge, we developed a platform to integrate and miniaturize many of the experimental steps required to study single-cell function. The heart of this platform is an elastomer-based Integrated Fluidic Circuit (IFC that uses fluidic logic to select and sequester specific single cells based on a phenotypic trait for downstream experimentation. Experiments with sequestered cells that have been performed include on-chip culture, exposure to a variety of stimulants, and post-exposure image-based response analysis, followed by preparation of the mRNA transcriptome for massively parallel sequencing analysis. The flexible system embodies experimental design and execution that enable routine functional studies of single cells.

  16. Fluorescence-based high-throughput functional profiling of ligand-gated ion channels at the level of single cells.

    Directory of Open Access Journals (Sweden)

    Sahil Talwar

    Full Text Available Ion channels are involved in many physiological processes and are attractive targets for therapeutic intervention. Their functional properties vary according to their subunit composition, which in turn varies in a developmental and tissue-specific manner and as a consequence of pathophysiological events. Understanding this diversity requires functional analysis of ion channel properties in large numbers of individual cells. Functional characterisation of ligand-gated channels involves quantitating agonist and drug dose-response relationships using electrophysiological or fluorescence-based techniques. Electrophysiology is limited by low throughput and high-throughput fluorescence-based functional evaluation generally does not enable the characterization of the functional properties of each individual cell. Here we describe a fluorescence-based assay that characterizes functional channel properties at single cell resolution in high throughput mode. It is based on progressive receptor activation and iterative fluorescence imaging and delivers >100 dose-responses in a single well of a 384-well plate, using α1-3 homomeric and αβ heteromeric glycine receptor (GlyR chloride channels as a model system. We applied this assay with transiently transfected HEK293 cells co-expressing halide-sensitive yellow fluorescent protein and different GlyR subunit combinations. Glycine EC50 values of different GlyR isoforms were highly correlated with published electrophysiological data and confirm previously reported pharmacological profiles for the GlyR inhibitors, picrotoxin, strychnine and lindane. We show that inter and intra well variability is low and that clustering of functional phenotypes permits identification of drugs with subunit-specific pharmacological profiles. As this method dramatically improves the efficiency with which ion channel populations can be characterized in the context of cellular heterogeneity, it should facilitate systems

  17. Some properties of generalized biregular functions with values in a Clifford algebra

    International Nuclear Information System (INIS)

    Le Hung Son; Tran Quyet Thang.

    1992-09-01

    In this paper some properties of holomorphic functions such as the Identity Theorem, the Maximum Modulus Principle, the Hartogs Extension Theorem are proved for a class of more general functions taking values in a Clifford algebra than the regular and biregular functions. (author). 7 refs

  18. Function of One Regular Separable Relation Set Decided for the Minimal Covering in Multiple Valued Logic

    Directory of Open Access Journals (Sweden)

    Liu Yu Zhen

    2016-01-01

    Full Text Available Multiple-valued logic is an important branch of the computer science and technology. Multiple-valued logic studies the theory, multiple-valued circuit & multiple-valued system, and the applications of multiple-valued logic included.In the theory of multiple-valued logic, one primary and important problem is the completeness of function sets, which can be solved depending on the decision for all the precomplete sets(also called maximal closed sets of K-valued function sets noted by PK*, and another is the decision for Sheffer function, which can be totally solved by picking out all of the minimal covering of the precomplete sets. In the function structure theory of multi-logic, decision on Sheffer function is an important role. It contains structure and decision of full multi-logic and partial multi-logic. Its decision is closely related to decision of completeness of function which can be done by deciding the minimal covering of full multi-logic and partial-logic. By theory of completeness of partial multi-logic, we prove that function of one regular separable relation is not minimal covering of PK* under the condition of m = 2, σ = e.

  19. Studies on the reference values of bone mineral content in Bulgarian women using single energy quantitative computed tomography

    International Nuclear Information System (INIS)

    Tsvetkova, S.; Semova, R.; Lichev, A.; Delov, I.

    1995-01-01

    Quantitative CT assessment of bone mineral content (BMC) is widely used in clinical practice. The results obtained from the examination of every single patient are compared with the reference values for the corresponding age and sex. It is known that BMC shows well recognized genetic, racial, ethnic and other differences. On the other hand, the introduction of different techniques, calibration phantoms, algorithms for choosing the region of interest, statistical models etc. leads to some differences in reference values. The authors present their own studies on the reference values of BMC in Bulgarian women using single energy quantitative computed tomography and a liquid K 2 HPO 4 calibration phantom. Different statistical models for data processing are proposed. The results are compared to the studies of recognized foreign authors. 17 refs., 3 tabs., 5 figs. (author)

  20. Reference values for paediatric pulmonary function testing: The Utrecht dataset.

    Science.gov (United States)

    Koopman, Marije; Zanen, Pieter; Kruitwagen, Cas L J J; van der Ent, Cornelis K; Arets, Hubertus G M

    2011-01-01

    Since populations evolve, measurement protocols and equipment improve and analysis techniques progress, there is an ongoing need to reassess reference data for pulmonary function tests. Furthermore, reference values for total lung capacity and carbon monoxide diffusion capacity are scarcely available in children. We aimed to provide updated reference equations for most commonly used pulmonary function indices in Caucasian children. In the 'Utrecht Pulmonary Function Reference Data Study' we collected data in Caucasian children aged 2-18 years. We analyzed them using the 'Generalized Additive Models for Location Scale and Shape' (GAMLSS) statistical method. Measurements of interrupter resistance (R(int)) (n = 877), spirometry (n = 1042), body plethysmography (n = 723) and carbon monoxide diffusion/helium dilution (n = 543) were obtained in healthy children. Height (or the natural logarithm of height) and age (or the natural logarithm of age) were both significantly related to most outcome measures. Also sex was a significant determinant, except for RV, RV/TLC, FRC(pleth), Raw(0,5), Raw(tot), R(int) and FEF values. The application of previously published reference equations on the study population resulted in misinterpretation of pulmonary function. These new paediatric reference equations provide accurate estimates of the range of normality for most commonly used pulmonary function indices, resulting in less underdiagnosis and overdiagnosis of pulmonary diseases. Copyright © 2010 Elsevier Ltd. All rights reserved.

  1. Computing single step operators of logic programming in radial basis function neural networks

    Science.gov (United States)

    Hamadneh, Nawaf; Sathasivam, Saratha; Choon, Ong Hong

    2014-07-01

    Logic programming is the process that leads from an original formulation of a computing problem to executable programs. A normal logic program consists of a finite set of clauses. A valuation I of logic programming is a mapping from ground atoms to false or true. The single step operator of any logic programming is defined as a function (Tp:I→I). Logic programming is well-suited to building the artificial intelligence systems. In this study, we established a new technique to compute the single step operators of logic programming in the radial basis function neural networks. To do that, we proposed a new technique to generate the training data sets of single step operators. The training data sets are used to build the neural networks. We used the recurrent radial basis function neural networks to get to the steady state (the fixed point of the operators). To improve the performance of the neural networks, we used the particle swarm optimization algorithm to train the networks.

  2. Computing single step operators of logic programming in radial basis function neural networks

    Energy Technology Data Exchange (ETDEWEB)

    Hamadneh, Nawaf; Sathasivam, Saratha; Choon, Ong Hong [School of Mathematical Sciences, Universiti Sains Malaysia, 11800 USM, Penang (Malaysia)

    2014-07-10

    Logic programming is the process that leads from an original formulation of a computing problem to executable programs. A normal logic program consists of a finite set of clauses. A valuation I of logic programming is a mapping from ground atoms to false or true. The single step operator of any logic programming is defined as a function (T{sub p}:I→I). Logic programming is well-suited to building the artificial intelligence systems. In this study, we established a new technique to compute the single step operators of logic programming in the radial basis function neural networks. To do that, we proposed a new technique to generate the training data sets of single step operators. The training data sets are used to build the neural networks. We used the recurrent radial basis function neural networks to get to the steady state (the fixed point of the operators). To improve the performance of the neural networks, we used the particle swarm optimization algorithm to train the networks.

  3. Computing single step operators of logic programming in radial basis function neural networks

    International Nuclear Information System (INIS)

    Hamadneh, Nawaf; Sathasivam, Saratha; Choon, Ong Hong

    2014-01-01

    Logic programming is the process that leads from an original formulation of a computing problem to executable programs. A normal logic program consists of a finite set of clauses. A valuation I of logic programming is a mapping from ground atoms to false or true. The single step operator of any logic programming is defined as a function (T p :I→I). Logic programming is well-suited to building the artificial intelligence systems. In this study, we established a new technique to compute the single step operators of logic programming in the radial basis function neural networks. To do that, we proposed a new technique to generate the training data sets of single step operators. The training data sets are used to build the neural networks. We used the recurrent radial basis function neural networks to get to the steady state (the fixed point of the operators). To improve the performance of the neural networks, we used the particle swarm optimization algorithm to train the networks

  4. Automatic single- and multi-label enzymatic function prediction by machine learning

    Directory of Open Access Journals (Sweden)

    Shervine Amidi

    2017-03-01

    Full Text Available The number of protein structures in the PDB database has been increasing more than 15-fold since 1999. The creation of computational models predicting enzymatic function is of major importance since such models provide the means to better understand the behavior of newly discovered enzymes when catalyzing chemical reactions. Until now, single-label classification has been widely performed for predicting enzymatic function limiting the application to enzymes performing unique reactions and introducing errors when multi-functional enzymes are examined. Indeed, some enzymes may be performing different reactions and can hence be directly associated with multiple enzymatic functions. In the present work, we propose a multi-label enzymatic function classification scheme that combines structural and amino acid sequence information. We investigate two fusion approaches (in the feature level and decision level and assess the methodology for general enzymatic function prediction indicated by the first digit of the enzyme commission (EC code (six main classes on 40,034 enzymes from the PDB database. The proposed single-label and multi-label models predict correctly the actual functional activities in 97.8% and 95.5% (based on Hamming-loss of the cases, respectively. Also the multi-label model predicts all possible enzymatic reactions in 85.4% of the multi-labeled enzymes when the number of reactions is unknown. Code and datasets are available at https://figshare.com/s/a63e0bafa9b71fc7cbd7.

  5. Functions and requirements for single-shell tank leakage mitigation

    International Nuclear Information System (INIS)

    Cruse, J.M.

    1994-01-01

    This document provides the initial functions and requirements for the leakage mitigation mission applicable to past and potential future leakage from the Hanford Site's 149 single-shell high-level waste tanks. This mission is a part of the overall mission of the Westinghouse Hanford Company Tank Waste Remediation System division to remediate the tank waste in a safe and acceptable manner. Systems engineering principles are being applied to this effort. A Mission Analysis has been completed, this document reflects the next step in the systems engineering approach to decompose the mission into primary functions and requirements. The functions and requirements in this document apply to mitigative actions to be taken regarding below ground leaks from SST containment boundaries and the resulting soil contamination. Leakage mitigation is invoked in the TWRS Program in three fourth level functions: (1) Store Waste, (2) Retrieve Waste, and (3) Disposition Excess Facilities

  6. Value Priorities and Behavior: Applying a Theory of Integrated Value Systems

    Directory of Open Access Journals (Sweden)

    Shalom Schwartz

    2016-02-01

    Full Text Available A major goal of research on values has been to relate individual differences in value priorities to differences in attitudes, behavior and background variables. Past research most commonly adopted one of two approaches. Much research has selected a few single target values whose priorities were postulated to associate with the attitude, behavior and background variable of interest and then examined empirical relationships. Other research has been more exploratory.It has related lists of values to various other variables and then discussed the significant associations that emerge. The focus on relationships with single values make both these approaches insatisfying. My work has sought to overcome those approaches.It has derived what may be a nearly comprehensive set of different motivational types of values, recognized across cultures. Each value type is represented by a number of single values that are combined to form relatively reliable indexes of values priorities. Value systems can be treated as integrated wholes in their relations with behaviors and, thereby, encourages researches to abandom the prevailing single-values approaches. 

  7. Official ERS technical standards: Global Lung Function Initiative reference values for the carbon monoxide transfer factor for Caucasians.

    Science.gov (United States)

    Stanojevic, Sanja; Graham, Brian L; Cooper, Brendan G; Thompson, Bruce R; Carter, Kim W; Francis, Richard W; Hall, Graham L

    2017-09-01

    There are numerous reference equations available for the single-breath transfer factor of the lung for carbon monoxide ( T  LCO ); however, it is not always clear which reference set should be used in clinical practice. The aim of the study was to develop the Global Lung Function Initiative (GLI) all-age reference values for T  LCO Data from 19 centres in 14 countries were collected to define T  LCO reference values. Similar to the GLI spirometry project, reference values were derived using the LMS (lambda, mu, sigma) method and the GAMLSS (generalised additive models for location, scale and shape) programme in R.12 660 T  LCO measurements from asymptomatic, lifetime nonsmokers were submitted; 85% of the submitted data were from Caucasians. All data were uncorrected for haemoglobin concentration. Following adjustments for elevation above sea level, gas concentration and assumptions used for calculating the anatomic dead space volume, there was a high degree of overlap between the datasets. Reference values for Caucasians aged 5-85 years were derived for T  LCO , transfer coefficient of the lung for carbon monoxide and alveolar volume.This is the largest collection of normative T  LCO data, and the first global reference values available for T  LCO . Copyright ©ERS 2017.

  8. A comparative study of single and multiple hand tasks using functional MRI

    International Nuclear Information System (INIS)

    Shin, Byung Suck; Lee, Ho Kyu; Park, Sung Tae; Kim, Dong Eun; Lee, Myung Jun; Choi, Choong Gon; Kim, Jae Kyun; Suh, Dae Chul; Lim, Tae Hwan

    1998-01-01

    The purpose of this study is to assess, using functional MRI and by comparing activated motor sensory areas, the independence of brain activation during single and alternative multiple hand tasks. The subjects were six healthy volunteers. Using at 1.5T Siemens system and single shot FID-EPI sequencing (T2 weighted image; TR/TE 0.96 msec/ 61msec, flip angle 90 deg, matrix size 96 x 128, slice thickness/gap 5 mm/0.8 mm, FOV 200 mm) and T1-weighted anatomic images, functional MRI was performed. The paradigm of motor tasks consisted of appositional finger movements; the first involved the separate use of the right, left, and both hands in sequence. Using cross-correlation method (threshold : 0.6) and fMRI analysis software (stimulate 5.0), functional images were obtained. The activated area of brain cortex, the number of pixel, the average percentage change in signal intensity, and correlation of the time-signal intensity curve in the activated motor area were analysed and compared between the two task groups. Statistical analysis involved the use of Wilcoxon signed-rank test. Brain activation did not differ according to whether the motor task was single or alternative. We therefore suggest that during multiple stimuli, the relevant functional area and neuronal column are activated independently. (author). 19 refs., 2 tabs., 3 figs

  9. Distribution of values of holomorphic mappings

    CERN Document Server

    Shabat, B V

    1985-01-01

    A vast literature has grown up around the value distribution theory of meromorphic functions, synthesized by Rolf Nevanlinna in the 1920s and singled out by Hermann Weyl as one of the greatest mathematical achievements of this century. The multidimensional aspect, involving the distribution of inverse images of analytic sets under holomorphic mappings of complex manifolds, has not been fully treated in the literature. This volume thus provides a valuable introduction to multivariate value distribution theory and a survey of some of its results, rich in relations to both algebraic and differential geometry and surely one of the most important branches of the modern geometric theory of functions of a complex variable. Since the book begins with preparatory material from the contemporary geometric theory of functions, only a familiarity with the elements of multidimensional complex analysis is necessary background to understand the topic. After proving the two main theorems of value distribution theory, the auth...

  10. Islamic Values in Spatial Function of Javanese Traditional Architecture

    Directory of Open Access Journals (Sweden)

    Supriyanta Supriyanta

    2016-01-01

    Full Text Available Learn from the past is important thing as based for the next step. Learn past architecture to gain positive values can be used as guidelines to design better architectural works. Javanese traditional architecture is one of local architecture from the past which has positive values, even if it is done deeper study; it has Islamic values which can be used as principles in the process of Islamic architectural design. To achieve Islamic values in spatial pattern Javanese traditional architecture can be done through exploration and reviewing Javanese traditional architectural space afterward it is associated with Islamic values which are relevant with Al Qur’an and sunnah prophet. In fact is the spatial pattern in Javanese traditional architecture arrayed with beauty and also has Islamic valuable function. Those Islamic values are 1 high esteem guest (pendopo through providing wide and comfortable living room; 2 create divider (pringgitan which separate between living room and main room so that the privation can be kept; 3 separation the bed room (gandok kiwo and gandok tengen between parents and their children who are going mature and also between boys and girls; 4 provide praying room (senthong tengah to pray as family education and also as a place to pray to the God.

  11. Application of extreme value distribution function in the determination of standard meteorological parameters for nuclear power plants

    International Nuclear Information System (INIS)

    Jiang Haimei; Liu Xinjian; Qiu Lin; Li Fengju

    2014-01-01

    Based on the meteorological data from weather stations around several domestic nuclear power plants, the statistical results of extreme minimum temperatures, minimum. central pressures of tropical cyclones and some other parameters are calculated using extreme value I distribution function (EV- I), generalized extreme value distribution function (GEV) and generalized Pareto distribution function (GP), respectively. The influence of different distribution functions and parameter solution methods on the statistical results of extreme values is investigated. Results indicate that generalized extreme value function has better applicability than the other two distribution functions in the determination of standard meteorological parameters for nuclear power plants. (authors)

  12. Functional connectivity with ventromedial prefrontal cortex reflects subjective value for social rewards.

    Science.gov (United States)

    Smith, David V; Clithero, John A; Boltuck, Sarah E; Huettel, Scott A

    2014-12-01

    According to many studies, the ventromedial prefrontal cortex (VMPFC) encodes the subjective value of disparate rewards on a common scale. Yet, a host of other reward factors-likely represented outside of VMPFC-must be integrated to construct such signals for valuation. Using functional magnetic resonance imaging (fMRI), we tested whether the interactions between posterior VMPFC and functionally connected brain regions predict subjective value. During fMRI scanning, participants rated the attractiveness of unfamiliar faces. We found that activation in dorsal anterior cingulate cortex, anterior VMPFC and caudate increased with higher attractiveness ratings. Using data from a post-scan task in which participants spent money to view attractive faces, we quantified each individual's subjective value for attractiveness. We found that connectivity between posterior VMPFC and regions frequently modulated by social information-including the temporal-parietal junction (TPJ) and middle temporal gyrus-was correlated with individual differences in subjective value. Crucially, these additional regions explained unique variation in subjective value beyond that extracted from value regions alone. These findings indicate not only that posterior VMPFC interacts with additional brain regions during valuation, but also that these additional regions carry information employed to construct the subjective value for social reward. © The Author (2014). Published by Oxford University Press. For Permissions, please email: journals.permissions@oup.com.

  13. Multiple kernel learning using single stage function approximation for binary classification problems

    Science.gov (United States)

    Shiju, S.; Sumitra, S.

    2017-12-01

    In this paper, the multiple kernel learning (MKL) is formulated as a supervised classification problem. We dealt with binary classification data and hence the data modelling problem involves the computation of two decision boundaries of which one related with that of kernel learning and the other with that of input data. In our approach, they are found with the aid of a single cost function by constructing a global reproducing kernel Hilbert space (RKHS) as the direct sum of the RKHSs corresponding to the decision boundaries of kernel learning and input data and searching that function from the global RKHS, which can be represented as the direct sum of the decision boundaries under consideration. In our experimental analysis, the proposed model had shown superior performance in comparison with that of existing two stage function approximation formulation of MKL, where the decision functions of kernel learning and input data are found separately using two different cost functions. This is due to the fact that single stage representation helps the knowledge transfer between the computation procedures for finding the decision boundaries of kernel learning and input data, which inturn boosts the generalisation capacity of the model.

  14. Validity of single-cycle objective functions for multicycle reload design optimization

    International Nuclear Information System (INIS)

    Kropaczek, D.J.; McElroy, J.; Turinsky, P.J.

    1993-01-01

    Beyond the equilibrium cycle scoping calculations used for determining numbers of feed assemblies and enrichment estimates, multicycle reload design currently consists of stagewise optimization of single-cycle core loading patterns, typically extending over a short-term planning horizon of perhaps three reload cycles. Particularly in transition cycles, however, optimizing a loading pattern over a single cycle for a stated objective, such as minimum core leakage, may have an adverse impact on subsequent cycles. The penalties paid may be in the form of reduced thermal margin or an increase in feed enrichment due to insufficient reactivity carryover from the open-quotes optimizedclose quotes cycle. In view of current practices, a study was performed that examined the behavior of the loading pattern as a function of the objective functions selected as implemented in the stagewise optimization of single-cycle core loading patterns from initial transition cycle through equilibrium using the FORMOSA-P code. The objective functions studied were region average discharge burnup maximization (with enrichment search) and feed enrichment minimization. It is noted at the beginning that the maximization of region average discharge has no meaning for the equilibrium cycle because region average discharge burnup is explicitly set by the feed size and cycle length independent of the loading pattern. In the nonequilibrium cycle, however, it was reasoned that this objective would provide the maximum reactivity carryover throughout the transition and thus have a direct effect on minimizing the multicycle levelized fuel cost

  15. Stability and Hopf Bifurcation of Fractional-Order Complex-Valued Single Neuron Model with Time Delay

    Science.gov (United States)

    Wang, Zhen; Wang, Xiaohong; Li, Yuxia; Huang, Xia

    2017-12-01

    In this paper, the problems of stability and Hopf bifurcation in a class of fractional-order complex-valued single neuron model with time delay are addressed. With the help of the stability theory of fractional-order differential equations and Laplace transforms, several new sufficient conditions, which ensure the stability of the system are derived. Taking the time delay as the bifurcation parameter, Hopf bifurcation is investigated and the critical value of the time delay for the occurrence of Hopf bifurcation is determined. Finally, two representative numerical examples are given to show the effectiveness of the theoretical results.

  16. Transverse single-spin asymmetry in the low-virtuality leptoproduction of open charm as a probe of the gluon Sivers function

    Science.gov (United States)

    Godbole, Rohini M.; Kaushik, Abhiram; Misra, Anuradha

    2018-04-01

    We study the low-virtuality inclusive leptoproduction of open charm, p↑l →D0+X as a probe of the gluon Sivers function. We perform the analysis in a generalized parton model framework. At leading order, this process is sensitive only to the gluon content of the proton. Hence any detection of a transverse single-spin asymmetry in this process would be clear indication of a non-zero gluon Sivers function (GSF). Considering COMPASS and a future Electron-Ion Collider (EIC), we present predictions for asymmetry using fits for the GSF available in literature. Predictions for peak asymmetry values lie in the range of 0.8% to 13%. We also present estimates of the upper bound on the asymmetry as obtained with a maximal gluon Sivers function. Further, for the case of the Electron-Ion Collider, we evaluate the asymmetry in the muons decaying from the D -meson and find that the asymmetry is well preserved in the kinematics of the muons. Peak values of the muon asymmetry are close to those obtained for the D -meson and lie in the range 0.75% to 11%.

  17. Intravital imaging of cardiac function at the single-cell level.

    Science.gov (United States)

    Aguirre, Aaron D; Vinegoni, Claudio; Sebas, Matt; Weissleder, Ralph

    2014-08-05

    Knowledge of cardiomyocyte biology is limited by the lack of methods to interrogate single-cell physiology in vivo. Here we show that contracting myocytes can indeed be imaged with optical microscopy at high temporal and spatial resolution in the beating murine heart, allowing visualization of individual sarcomeres and measurement of the single cardiomyocyte contractile cycle. Collectively, this has been enabled by efficient tissue stabilization, a prospective real-time cardiac gating approach, an image processing algorithm for motion-artifact-free imaging throughout the cardiac cycle, and a fluorescent membrane staining protocol. Quantification of cardiomyocyte contractile function in vivo opens many possibilities for investigating myocardial disease and therapeutic intervention at the cellular level.

  18. Antisymmetrized four-body wave function and coexistence of single particle and cluster structures

    International Nuclear Information System (INIS)

    Sasakawa, T.

    1979-01-01

    It is shown that each Yakubovski component of the totally antisymmetric four-body wave function satisfies the same equation as the unantisymmetric wave function. In the antisymmetric total wave function, the wave functions belonging to the same kind of partition are totally antisymmetric among themselves. This leads to the coexistence of cluster models, including the single particle model as a special case of the cluster model, as a sum

  19. Adaptive singular value cancelation of ventricular activity in single-lead atrial fibrillation electrocardiograms

    International Nuclear Information System (INIS)

    Alcaraz, Raúl; Rieta, José Joaquín

    2008-01-01

    The proper analysis and characterization of atrial fibrillation (AF) from surface electrocardiographic (ECG) recordings requires to cancel out the ventricular activity (VA), which is composed of the QRS complex and the T wave. Historically, for single-lead ECGs, the averaged beat subtraction (ABS) has been the most widely used technique. However, this method is very sensitive to QRST wave variations and, moreover, high-quality cancelation templates may be difficult to obtain when only short length and single-lead recordings are available. In order to overcome these limitations, a new QRST cancelation method based on adaptive singular value cancelation (ASVC) applied to each single beat is proposed. In addition, an exhaustive study about the optimal set of complexes for better cancelation of every beat is also presented for the first time. The whole study has been carried out with both simulated and real AF signals. For simulated AF, the cancelation performance was evaluated making use of a cross-correlation index and the normalized mean square error (nmse) between the estimated and the original atrial activity (AA). For real AF signals, two additional new parameters were proposed. First, the ventricular residue (VR) index estimated the presence of ventricular activity in the extracted AA. Second, the similarity (S) evaluated how the algorithm preserved the AA segments out of the QRST interval. Results indicated that for simulated AF signals, mean correlation, nmse, VR and S values were 0.945 ± 0.024, 0.332 ± 0.073, 1.552 ± 0.386 and 0.986 ± 0.012, respectively, for the ASVC method and 0.866 ± 0.042, 0.424 ± 0.120, 2.161 ± 0.564 and 0.922 ± 0.051 for ABS. In the case of real signals, the mean VR and S values were 1.725 ± 0.826 and 0.983 ± 0.038, respectively, for ASVC and 3.159 ± 1.097 and 0.951 ± 0.049 for ABS. Thus, ASVC provides a more accurate beat-to-beat ventricular QRST representation than traditional techniques. As a consequence, VA cancelation

  20. Single amino acid substitution in important hemoglobinopathies does not disturb molecular function and biological process

    Directory of Open Access Journals (Sweden)

    Viroj Wiwanitkit

    2008-06-01

    Full Text Available Viroj WiwanitkitDepartment of Laboratory Medicine, Faculty of Medicine, Chulalongkorn University, Bangkok, ThailandAbstract: Hemoglobin is an important protein found in the red cells of many animals. In humans, the hemoglobin is mainly distributed in the red blood cell. Single amino acid substitution is the main pathogenesis of most hemoglobin disorders. Here, the author used a new gene ontology technology to predict the molecular function and biological process of four important hemoglobin disorders with single substitution. The four studied important abnormal hemoglobins (Hb with single substitution included Hb S, Hb E, Hb C, and Hb J-Baltimore. Using the GoFigure server, the molecular function and biological process in normal and abnormal hemoglobins was predicted. Compared with normal hemoglobin, all studied abnormal hemoglobins had the same function and biological process. This indicated that the overall function of oxygen transportation is not disturbed in the studied hemoglobin disorders. Clinical findings of oxygen depletion in abnormal hemoglobin should therefore be due to the other processes rather than genomics, proteomics, and expression levels.Keywords: hemoglobin, amino acid, substitution, function

  1. Magnon specific heat and free energy of Heisenberg ferromagnetic single-walled nanotubes: Green's function approach

    Energy Technology Data Exchange (ETDEWEB)

    Mi, Bin-Zhou, E-mail: mbzfjerry2008@126.com [Department of Basic Curriculum, North China Institute of Science and Technology, Beijing 101601 (China); Department of Physics, School of Mathematics and Physics, University of Science and Technology Beijing, Beijing 100083 (China); Zhai, Liang-Jun [The School of Mathematics and Physics, Jiangsu University of Technology, Changzhou 213001 (China); Hua, Ling-Ling [Department of Basic Curriculum, North China Institute of Science and Technology, Beijing 101601 (China)

    2016-01-15

    The effect of magnetic spin correlation on the thermodynamic properties of Heisenberg ferromagnetic single-walled nanotubes are comprehensively investigated by use of the double-time Green's function method. The influence of temperature, spin quantum number, diameter of the tube, anisotropy strength and external magnetic field to internal energy, free energy, and magnon specific heat are carefully calculated. Compared to the mean field approximation, the consideration of the magnetic correlation effect significantly improves the internal energy values at finite temperature, while it does not so near zero temperature, and this effect is related to the diameter of the tube, anisotropy strength, and spin quantum number. The magnetic correlation effect lowers the internal energy at finite temperature. As a natural consequence of the reduction of the internal energy, the specific heat is reduced, and the free energy is elevated. - Highlights: • Magnon specific heat and free energy of Heisenberg ferromagnetic single-walled nanotubes (HFM-SWNTs) are investigated. • The magnetic correlations effect has a considerable contribution to the thermodynamics properties of HFM-SWNTs. • Magnetic correlation effects are always to lower the internal energy at finite temperature. • At Curie point, magnetic correlation energy is much less than zero. • The peak values of magnon specific heat curves rise and shift right towards higher temperatures with the diameter of tubes, the anisotropy strength, and the spin quantum number rising.

  2. The value function as a criterion of analysis in separation technologies

    International Nuclear Information System (INIS)

    Peculea, Marius

    2005-01-01

    Production costs of heavy water are described by two functions: φ(ε), the energy function which represents the variable costs and φ(τ), the technologic function which represents the stable costs. The Dirac value function related to the circulation in the separation cascade allows calculating φ(ε) and consequently the technologic function may be represented in relation to the specific separation process. This representation allows the qualitative analysis of different separation processes or, for a given process, provides the analysis of different technological solutions which were worked out. An example is given referring to the analysis of heavy water technologies of separation through the dual temperature process of H 2 O-H 2 S isotopic exchange

  3. Electronic diffraction tomography by Green's functions and singular values decompositions

    International Nuclear Information System (INIS)

    Mayer, A.

    2001-01-01

    An inverse scattering technique is developed to enable a three-dimensional sample reconstruction from the diffraction figures obtained for different sample orientations by electronic projection microscopy, thus performing a diffraction tomography. In its Green's-functions formulation, this technique takes account of all orders of diffraction by performing an iterative reconstruction of the wave function on the observation screen and in the sample. In a final step, these quantities enable a reconstruction of the potential-energy distribution, which is assumed real valued. The method relies on the use of singular values decomposition techniques, thus providing the best least-squares solutions and enabling a reduction of noise. The technique is applied to the analysis of a three-dimensional nanometric sample that is observed in Fresnel conditions with an electron energy of 40 eV. The algorithm turns out to provide results with a mean relative error around 3% and to be stable against random noise

  4. Four-dimensional echocardiography area strain combined with exercise stress echocardiography to evaluate left ventricular regional systolic function in patients with mild single vessel coronary artery stenosis.

    Science.gov (United States)

    Deng, Yan; Peng, Long; Liu, Yuan-Yuan; Yin, Li-Xue; Li, Chun-Mei; Wang, Yi; Rao, Li

    2017-09-01

    The aim of this prospective study was to assess the diagnosis value of four-dimensional echocardiography area strain (AS) combined with exercise stress echocardiography to evaluate left ventricular regional systolic function in patients with mild single vessel coronary artery stenosis. Based on treadmill exercise load status, two-dimensional conventional echocardiography and four-dimensional echocardiography area strain were performed on patients suspected coronary artery disease before coronary angiogram. Thirty patients (case group) with mild left anterior descending coronary artery stenosis (stenosis Four-dimensional echocardiography area strain combined with exercise stress echocardiography could sensitively find left ventricular regional systolic function abnormality in patients with mild single vessel coronary artery stenosis, and locate stenosis coronary artery accordingly. © 2017, Wiley Periodicals, Inc.

  5. Extensions of vector-valued functions with preservation of derivatives

    Czech Academy of Sciences Publication Activity Database

    Koc, M.; Kolář, Jan

    2017-01-01

    Roč. 449, č. 1 (2017), s. 343-367 ISSN 0022-247X R&D Projects: GA ČR(CZ) GA14-07880S Institutional support: RVO:67985840 Keywords : vector-valued differentiable functions * extensions * strict differentiability * partitions of unity Subject RIV: BA - General Mathematics OBOR OECD: Pure mathematics Impact factor: 1.064, year: 2016 http://www.sciencedirect.com/science/article/pii/S0022247X16307703

  6. Predictive Value of Upper Limb Muscles and Grasp Patterns on Functional Outcome in Cervical Spinal Cord Injury.

    Science.gov (United States)

    Velstra, Inge-Marie; Bolliger, Marc; Krebs, Jörg; Rietman, Johan S; Curt, Armin

    2016-05-01

    To determine which single or combined upper limb muscles as defined by the International Standards for the Neurological Classification of Spinal Cord Injury (ISNCSCI); upper extremity motor score (UEMS) and the Graded Redefined Assessment of Strength, Sensibility, and Prehension (GRASSP), best predict upper limb function and independence in activities of daily living (ADLs) and to assess the predictive value of qualitative grasp movements (QlG) on upper limb function in individuals with acute tetraplegia. As part of a Europe-wide, prospective, longitudinal, multicenter study ISNCSCI, GRASSP, and Spinal Cord Independence Measure (SCIM III) scores were recorded at 1 and 6 months after SCI. For prediction of upper limb function and ADLs, a logistic regression model and unbiased recursive partitioning conditional inference tree (URP-CTREE) were used. Results: Logistic regression and URP-CTREE revealed that a combination of ISNCSCI and GRASSP muscles (to a maximum of 4) demonstrated the best prediction (specificity and sensitivity ranged from 81.8% to 96.0%) of upper limb function and identified homogenous outcome cohorts at 6 months. The URP-CTREE model with the QlG predictors for upper limb function showed similar results. Prediction of upper limb function can be achieved through a combination of defined, specific upper limb muscles assessed in the ISNCSCI and GRASSP. A combination of a limited number of proximal and distal muscles along with an assessment of grasping movements can be applied for clinical decision making for rehabilitation interventions and clinical trials. © The Author(s) 2015.

  7. Single step synthesis, characterization and applications of curcumin functionalized iron oxide magnetic nanoparticles

    Energy Technology Data Exchange (ETDEWEB)

    Bhandari, Rohit; Gupta, Prachi; Dziubla, Thomas; Hilt, J. Zach, E-mail: zach.hilt@uky.edu

    2016-10-01

    Magnetic iron oxide nanoparticles have been well known for their applications in magnetic resonance imaging (MRI), hyperthermia, targeted drug delivery, etc. The surface modification of these magnetic nanoparticles has been explored extensively to achieve functionalized materials with potential application in biomedical, environmental and catalysis field. Herein, we report a novel and versatile single step methodology for developing curcumin functionalized magnetic Fe{sub 3}O{sub 4} nanoparticles without any additional linkers, using a simple coprecipitation technique. The magnetic nanoparticles (MNPs) were characterized using transmission electron microscopy, X-ray diffraction, fourier transform infrared spectroscopy and thermogravimetric analysis. The developed MNPs were employed in a cellular application for protection against an inflammatory agent, a polychlorinated biphenyl (PCB) molecule. - Graphical abstract: Novel single step curcumin coated magnetic Fe{sub 3}O{sub 4} nanoparticles without any additional linkers for medical, environmental, and other applications. Display Omitted - Highlights: • A novel and versatile single step methodology for developing curcumin functionalized magnetic Fe{sub 3}O{sub 4} nanoparticles is reported. • The magnetic nanoparticles (MNPs) were characterized using TEM, XRD, FTIR and TGA. • The developed MNPs were employed in a cellular application for protection against an inflammatory agent, a polychlorinated biphenyl (PCB).

  8. Phototransformation-Induced Aggregation of Functionalized Single-Walled Carbon Nanotubes: The Importance of Amorphous Carbon

    Science.gov (United States)

    Single-walled carbon nanotubes (SWCNTs) with proper functionalization are desirable for applications that require dispersion in aqueous and biological environments, and functionalized SWCNTs also serve as building blocks for conjugation with specific molecules in these applicatio...

  9. Prospect theory does not describe the feedback-related negativity value function.

    Science.gov (United States)

    Sambrook, Thomas D; Roser, Matthew; Goslin, Jeremy

    2012-12-01

    Humans handle uncertainty poorly. Prospect theory accounts for this with a value function in which possible losses are overweighted compared to possible gains, and the marginal utility of rewards decreases with size. fMRI studies have explored the neural basis of this value function. A separate body of research claims that prediction errors are calculated by midbrain dopamine neurons. We investigated whether the prospect theoretic effects shown in behavioral and fMRI studies were present in midbrain prediction error coding by using the feedback-related negativity, an ERP component believed to reflect midbrain prediction errors. Participants' stated satisfaction with outcomes followed prospect theory but their feedback-related negativity did not, instead showing no effect of marginal utility and greater sensitivity to potential gains than losses. Copyright © 2012 Society for Psychophysiological Research.

  10. Realization of Arbitrary Positive-Operator-Value Measurement of Single Atomic Qubit via Cavity QED

    International Nuclear Information System (INIS)

    Yang, Han; Wei, Wu; Chun-Wang, Wu; Hong-Yi, Dai; Cheng-Zu, Li

    2008-01-01

    Positive-operator-value measurement (POVM) is the most general class of quantum measurement. We propose a scheme to deterministically implement arbitrary POVMs of single atomic qubit via cavity QED catalysed by only one ancilla atomic qubit. By appropriately entangling two atomic qubits and sequentially measuring the ancilla qubit, any POVM can be implemented step by step. As an application of our scheme, the realization of a specific POVM for optimal unambiguous discrimination (OUD) between two nonorthogonal states is given

  11. Realization of Arbitrary Positive-Operator-Value Measurement of Single Atomic Qubit via Cavity QED

    Science.gov (United States)

    Han, Yang; Wu, Wei; Wu, Chun-Wang; Dai, Hong-Yi; Li, Cheng-Zu

    2008-12-01

    Positive-operator-value measurement (POVM) is the most general class of quantum measurement. We propose a scheme to deterministically implement arbitrary POVMs of single atomic qubit via cavity QED catalysed by only one ancilla atomic qubit. By appropriately entangling two atomic qubits and sequentially measuring the ancilla qubit, any POVM can be implemented step by step. As an application of our scheme, the realization of a specific POVM for optimal unambiguous discrimination (OUD) between two nonorthogonal states is given.

  12. Clinical impact and value of workstation single sign-on.

    Science.gov (United States)

    Gellert, George A; Crouch, John F; Gibson, Lynn A; Conklin, George S; Webster, S Luke; Gillean, John A

    2017-05-01

    CHRISTUS Health began implementation of computer workstation single sign-on (SSO) in 2015. SSO technology utilizes a badge reader placed at each workstation where clinicians swipe or "tap" their identification badges. To assess the impact of SSO implementation in reducing clinician time logging in to various clinical software programs, and in financial savings from migrating to a thin client that enabled replacement of traditional hard drive computer workstations. Following implementation of SSO, a total of 65,202 logins were sampled systematically during a 7day period among 2256 active clinical end users for time saved in 6 facilities when compared to pre-implementation. Dollar values were assigned to the time saved by 3 groups of clinical end users: physicians, nurses and ancillary service providers. The reduction of total clinician login time over the 7day period showed a net gain of 168.3h per week of clinician time - 28.1h (2.3 shifts) per facility per week. Annualized, 1461.2h of mixed physician and nursing time is liberated per facility per annum (121.8 shifts of 12h per year). The annual dollar cost savings of this reduction of time expended logging in is $92,146 per hospital per annum and $1,658,745 per annum in the first phase implementation of 18 hospitals. Computer hardware equipment savings due to desktop virtualization increases annual savings to $2,333,745. Qualitative value contributions to clinician satisfaction, reduction in staff turnover, facilitation of adoption of EHR applications, and other benefits of SSO are discussed. SSO had a positive impact on clinician efficiency and productivity in the 6 hospitals evaluated, and is an effective and cost-effective method to liberate clinician time from repetitive and time consuming logins to clinical software applications. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.

  13. Predictive value of plasma β2-microglobulin on human body function and senescence.

    Science.gov (United States)

    Dong, X-M; Cai, R; Yang, F; Zhang, Y-Y; Wang, X-G; Fu, S-L; Zhang, J-R

    2016-06-01

    To explore the correlation between plasma β2-microglobulin (β2-MG) as senescence factor with age, heart, liver and kidney function as well as the predictive value of β2-MG in human metabolism function and senescence. 387 cases of healthy people of different ages were selected and the automatic biochemical analyzer was used to test β2-MG in plasma based on immunoturbidimetry and also all biochemical indexes. The correlation between β2-MG and age, gender and all biochemical indexes was analyzed. β2-MG was positively correlated to age, r = 0.373; and the difference was of statistical significance (p human body function and anti-senescence and have significant basic research and clinical guidance values.

  14. A micromotor based on polymer single crystals and nanoparticles: toward functional versatility

    Science.gov (United States)

    Liu, Mei; Liu, Limei; Gao, Wenlong; Su, Miaoda; Ge, Ya; Shi, Lili; Zhang, Hui; Dong, Bin; Li, Christopher Y.

    2014-07-01

    We report a multifunctional micromotor fabricated by the self-assembly technique using multifunctional materials, i.e. polymer single crystals and nanoparticles, as basic building blocks. Not only can this micromotor achieve autonomous and directed movement, it also possesses unprecedented functions, including enzymatic degradation-induced micromotor disassembly, sustained release and molecular detection.We report a multifunctional micromotor fabricated by the self-assembly technique using multifunctional materials, i.e. polymer single crystals and nanoparticles, as basic building blocks. Not only can this micromotor achieve autonomous and directed movement, it also possesses unprecedented functions, including enzymatic degradation-induced micromotor disassembly, sustained release and molecular detection. Electronic supplementary information (ESI) available: Experimental section, Fig. S1-S8 and Video S1-S4. See DOI: 10.1039/c4nr02593h

  15. The boundary value problem for discrete analytic functions

    KAUST Repository

    Skopenkov, Mikhail

    2013-06-01

    This paper is on further development of discrete complex analysis introduced by R.Isaacs, J.Ferrand, R.Duffin, and C.Mercat. We consider a graph lying in the complex plane and having quadrilateral faces. A function on the vertices is called discrete analytic, if for each face the difference quotients along the two diagonals are equal.We prove that the Dirichlet boundary value problem for the real part of a discrete analytic function has a unique solution. In the case when each face has orthogonal diagonals we prove that this solution uniformly converges to a harmonic function in the scaling limit. This solves a problem of S.Smirnov from 2010. This was proved earlier by R.Courant-K.Friedrichs-H.Lewy and L.Lusternik for square lattices, by D.Chelkak-S.Smirnov and implicitly by P.G.Ciarlet-P.-A.Raviart for rhombic lattices.In particular, our result implies uniform convergence of the finite element method on Delaunay triangulations. This solves a problem of A.Bobenko from 2011. The methodology is based on energy estimates inspired by alternating-current network theory. © 2013 Elsevier Ltd.

  16. The Positron-Electron Correlation Energy In ZnO Calculated With The Modified Single Wave Function Of Positron

    International Nuclear Information System (INIS)

    Chau Van Tao; Trinh Hoa Lang; Le Hoang Chien; Nguyen Huu Loc; Nguyen Anh Tuan

    2011-01-01

    Positron-electron correlation energy of the ZnO - positron system is studied on assumption that positron binds with the outer shell electrons of Zinc and Oxygen to form the pseudo ZnO - positron molecule before it annihilates with one of these electrons. In this work, the single wave function for positron is form by LCAO approximation and is modified according to the principle of linear superposition, and by using Variational Quantum Monte Carlo method (VQMC) [7] the correlation energy of this system is estimated with the value E c e-p = - 9.3 ± 1.1 eV. In the theoretical aspect it turns out that this result is more reasonable and closer to those of other methods [3] than the one which is done without modifying the wave function of positron [1]. To confirm this legitimate approach, however, the further calculations of positron annihilation rate in ZnO have to be carried out in our next work. (author)

  17. Illuminant direction estimation for a single image based on local region complexity analysis and average gray value.

    Science.gov (United States)

    Yi, Jizheng; Mao, Xia; Chen, Lijiang; Xue, Yuli; Compare, Angelo

    2014-01-10

    Illuminant direction estimation is an important research issue in the field of image processing. Due to low cost for getting texture information from a single image, it is worthwhile to estimate illuminant direction by employing scenario texture information. This paper proposes a novel computation method to estimate illuminant direction on both color outdoor images and the extended Yale face database B. In our paper, the luminance component is separated from the resized YCbCr image and its edges are detected with the Canny edge detector. Then, we divide the binary edge image into 16 local regions and calculate the edge level percentage in each of them. Afterward, we use the edge level percentage to analyze the complexity of each local region included in the luminance component. Finally, according to the error function between the measured intensity and the calculated intensity, and the constraint function for an infinite light source model, we calculate the illuminant directions of the luminance component's three local regions, which meet the requirements of lower complexity and larger average gray value, and synthesize them as the final illuminant direction. Unlike previous works, the proposed method requires neither all of the information of the image nor the texture that is included in the training set. Experimental results show that the proposed method works better at the correct rate and execution time than the existing ones.

  18. Acoustic effects of single electrostatic discharges

    International Nuclear Information System (INIS)

    Orzech, Łukasz

    2015-01-01

    Electric discharges, depending on their character, can emit different types of energy, resulting in different effects. Single electrostatic discharges besides generation of electromagnetic pulses are also the source of N acoustic waves. Their specified parameters depending on amount of discharging charge enable determination of value of released charge in a function of acoustic descriptor (e.g. acoustic pressure). Presented approach is the basics of acoustic method for measurement of single electrostatic discharges, enabling direct and contactless measurement of value of charge released during ESD. Method for measurement of acoustic effect of impact of a single electrostatic discharge on the environment in a form of pressure shock wave and examples of acoustic descriptors in a form of equation Q=f(p a ) are described. The properties of measuring system as well as the results of regression static analyses used to determine the described relationships are analysed in details. (paper)

  19. Single-Family Housing Value Resilience of Walkable Versus Unwalkable Neighborhoods During a Market Downturn: Causal Evidence and Policy Implications.

    Science.gov (United States)

    Xu, Minjie; Yu, Chia-Yuan; Lee, Chanam; Frank, Lawrence D

    2018-01-01

    This study investigated the resilience of single-family housing values in walkable versus unwalkable neighborhoods during the economic downturn from 2008 to 2012 in Dallas, Texas. Using propensity score matching and difference in differences methods, this study established a natural experimental design to compare before-and-after value changes of single-family (SF) homes in walkable neighborhoods with unwalkable neighborhoods during the Great Recession. Two thousand seven hundred ninety-nine SF homes within 18 Tax Increment Financing (TIF) districts were categorized into walkable (Walk Score ≥50) and unwalkable (economic benefit. Increased awareness of the sustained value of walkable communities can be used by lenders who finance and by policy makers who regulate placemaking. Results from this study can be integrated with research that demonstrates health-care cost savings of walkable environments to create an even more comprehensive set of evidence-based interventions to increase their supply.

  20. Spectrally Resolved and Functional Super-resolution Microscopy via Ultrahigh-Throughput Single-Molecule Spectroscopy.

    Science.gov (United States)

    Yan, Rui; Moon, Seonah; Kenny, Samuel J; Xu, Ke

    2018-03-20

    As an elegant integration of the spatial and temporal dimensions of single-molecule fluorescence, single-molecule localization microscopy (SMLM) overcomes the diffraction-limited resolution barrier of optical microscopy by localizing single molecules that stochastically switch between fluorescent and dark states over time. While this type of super-resolution microscopy (SRM) technique readily achieves remarkable spatial resolutions of ∼10 nm, it typically provides no spectral information. Meanwhile, current scanning-based single-location approaches for mapping the positions and spectra of single molecules are limited by low throughput and are difficult to apply to densely labeled (bio)samples. In this Account, we summarize the rationale, design, and results of our recent efforts toward the integration of the spectral dimension of single-molecule fluorescence with SMLM to achieve spectrally resolved SMLM (SR-SMLM) and functional SRM ( f-SRM). By developing a wide-field scheme for spectral measurement and implementing single-molecule fluorescence on-off switching typical of SMLM, we first showed that in densely labeled (bio)samples it is possible to record the fluorescence spectra and positions of millions of single molecules synchronously within minutes, giving rise to ultrahigh-throughput single-molecule spectroscopy and SR-SMLM. This allowed us to first show statistically that for many dyes, single molecules of the same species exhibit near identical emission in fixed cells. This narrow distribution of emission wavelengths, which contrasts markedly with previous results at solid surfaces, allowed us to unambiguously identify single molecules of spectrally similar dyes. Crosstalk-free, multiplexed SRM was thus achieved for four dyes that were merely 10 nm apart in emission spectrum, with the three-dimensional SRM images of all four dyes being automatically aligned within one image channel. The ability to incorporate single-molecule fluorescence measurement with

  1. From tomography to FWI with a single objective function

    KAUST Repository

    Alkhalifah, Tariq Ali

    2013-06-10

    Reflections in our seismic data induce serious nonlinear behavior in the objective function of full waveform inversion (FWI). Thus, without a good initial velocity model, that can produce the reflections within a cycle of the frequency used in the inversion, convergence to the solution becomes hard. Such velocity models are usually extracted from migration velocity analysis or traveltime tomography, among other means, that are not guaranteed to adhere to the FWI requirements. As such, we promote an objective function based on the misfit in the instantaneous traveltime between the observed and modeled data. This phase based attribute of the wavefield, along with its phase unwrapping features, provide a frequency dependent traveltime function. With strong damping of the of the synthetic, potentially low frequency, data, this attribute admits first arrival traveltime that could be compared with picked ones from the observed data, like in wave equation tomography. As we relax the damping on the synthetic and observed data, the objective function measures the misfit in the phase, however unwrapped in an FWI type inversion. It, thus, provides a single objective function and a natural transition from traveltime tomography to full waveform inversion. A Marmousi example demonstrates the effectiveness of the approach.

  2. Realization of arbitrary positive-operator-value measurement of single atomic qubit via cavity QED

    International Nuclear Information System (INIS)

    Han Yang; Wu Wei; Wu Chunwang; Dai Hongyi; Li Chengzu

    2008-01-01

    Positive-operator-value measurement (POVM) is the most general class of quantum measurement. We propose a scheme to deterministically implement arbitrary POVMs of single atomic qubit via cavity QED catalysed by only one ancilla atomic qubit. By appropriately entangling two atomic qubits and sequentially measuring the ancilla qubit, any POVM can be implemented step by step. As an application of our scheme, the realization of a specific POVM for optimal unambiguous discrimination (OUD) between two nonorthogonal states is given. (authors)

  3. Correlation functions of σ fields with values in a hyperbolic space

    International Nuclear Information System (INIS)

    Haba, Z.

    1989-01-01

    It is shown that the functional integral for a σ field with values in the Poincare upper half-plane (and some other hyperbolic spaces) can be performed explicitly resulting in a conformal invariant noncanonical field theory in two dimensions

  4. Correlation Functions of σ Fields with Values in a Hyperbolic Space

    Science.gov (United States)

    Haba, Z.

    It is shown that the functional integral for a σ field with values in the Poincare upper half-plane (and some other hyperbolic spaces) can be performed explicitly resulting in a conformal invariant noncanonical field theory in two dimensions.

  5. Value Distribution and Uniqueness Results of Zero-Order Meromorphic Functions to Their q-Shift

    Directory of Open Access Journals (Sweden)

    Haiwa Guan

    2012-01-01

    Full Text Available We investigate value distribution and uniqueness problems of meromorphic functions with their q-shift. We obtain that if f is a transcendental meromorphic (or entire function of zero order, and Q(z is a polynomial, then afn(qz+f(z−Q(z has infinitely many zeros, where q∈ℂ∖{0}, a is nonzero constant, and n≥5 (or n≥3. We also obtain that zero-order meromorphic function share is three distinct values IM with its q-difference polynomial P(f, and if limsup r→∞(N(r,f/T(r,f<1, then f≡P(f.

  6. Relative work function of clean molybdenum single-crystal planes determined by field emission microscopy

    International Nuclear Information System (INIS)

    Bergeret, G.; Abon, M.; Tardy, B.; Teichner, S.J.

    1974-01-01

    A probe-hole field emission microscope was used to determine the work function of clean molybdenum single crystal planes relative to the average work function of the field emitter, assumed to be 4.20 eV. Results are compared with other available data

  7. Ultrafast carrier dynamics in pentacene, functionalized pentacene, tetracene, and rubrene single crystals

    NARCIS (Netherlands)

    Ostroverkhova, O; Cooke, DG; Hegmann, FA; Anthony, JE; Podzorov, [No Value; Gershenson, ME; Jurchescu, OD; Palstra, TTM

    2006-01-01

    We measure the transient photoconductivity in pentacene, functionalized pentacene, tetracene, and rubrene single crystals using optical pump-terahertz probe techniques. In all of the samples studied, we observe subpicosecond charge photogeneration and a peak photoconductive response that increases

  8. Single-” and “multi-core” FePt nanoparticles: from controlled synthesis via zwitterionic and silica bio-functionalization to MRI applications

    Energy Technology Data Exchange (ETDEWEB)

    Kostevšek, Nina, E-mail: nina.kostevsek@ijs.si; Šturm, Sašo [Jožef Stefan Institute, Department for Nanostructured Materials (Slovenia); Serša, Igor; Sepe, Ana [Jožef Stefan Institute, Department for Condensed Matter Physics (Slovenia); Bloemen, Maarten; Verbiest, Thierry [KU Leuven, Department of Chemistry (Belgium); Kobe, Spomenka; Žužek Rožman, Kristina [Jožef Stefan Institute, Department for Nanostructured Materials (Slovenia)

    2015-12-15

    The value of the magnetization has a strong influence on the performance of nanoparticles that act as the contrast agent material for MRI. In this article, we describe processing routes for the synthesis of FePt nanoparticles of different sizes, which, as a result, exhibit different magnetization values. “Single-core” FePt nanoparticles of different sizes (3–15 nm) were prepared via one-step or two-step synthesis, with the latter exhibiting twice the magnetization (m{sub (1.5T)} = 14.5 emu/g) of the nanoparticles formed via the one-step synthesis (m{sub (1.5T)} < 8 emu/g). Furthermore, we propose the synthesis of “multi-core” FePt nanoparticles by changing the ratio between the two surfactants (oleylamine and oleic acid). The step from smaller “single-core” FePt nanoparticles towards the larger, “multi-core” FePt nanoparticles (>20 nm) leads to an increase in the magnetization m{sub (1.5T)} from 8 to 19.5 emu/g, without exceeding the superparamagnetic limit. Stable water suspensions were prepared using two different approaches: (a) functionalization with a biocompatible, zwitterionic, catechol ligand, which was used on the FePt nanoparticles for the first time, and (b) coating with SiO{sub 2} shells of various thicknesses. These FePt-based nanostructures, the catechol- and SiO{sub 2}-coated “single-core” and “multi-core” FePt nanoparticles, were investigated in terms of the relaxation rates. The higher r{sub 2} values obtained for the “multi-core” FePt nanoparticles compared to that for the “single-core” ones indicate the superiority of the “multi-core” FePt nanoparticles as T{sub 2} contrast agents. Furthermore, it was shown that the SiO{sub 2} coating reduces the r{sub 1} and r{sub 2} relaxation values for both the “single-core” and “multi-core” FePt nanoparticles. The high r{sub 2}/r{sub 1} ratios obtained in our study put FePt nanoparticles near the top of the list of candidate materials for use in MRI

  9. Neutron Transmission of Single-crystal Sapphire Filters

    Science.gov (United States)

    Adib, M.; Kilany, M.; Habib, N.; Fathallah, M.

    2005-05-01

    An additive formula is given that permits the calculation of the nuclear capture, thermal diffuse and Bragg scattering cross-sections as a function of sapphire temperature and crystal parameters. We have developed a computer program that allows calculations of the thermal neutron transmission for the sapphire rhombohedral structure and its equivalent trigonal structure. The calculated total cross-section values and effective attenuation coefficient for single-crystalline sapphire at different temperatures are compared with measured values. Overall agreement is indicated between the formula and experimental data. We discuss the use of sapphire single crystal as a thermal neutron filter in terms of the optimum cystal thickness, mosaic spread, temperature, cutting plane and tuning for efficient transmission of thermal-reactor neutrons.

  10. Logarithmic residues of analytic Banach algebra valued functions possessing a simply meromorphic inverse

    NARCIS (Netherlands)

    H. Bart (Harm); T. Ehrhardt; B. Silbermann

    2001-01-01

    textabstractA logarithmic residue is a contour integral of a logarithmic derivative (left or right) of an analytic Banach algebra valued function. For functions possessing a meromorphic inverse with simple poles only, the logarithmic residues are identified as the sums of idempotents. With the help

  11. A single-sided homogeneous Green's function representation for holographic imaging, inverse scattering, time-reversal acoustics and interferometric Green's function retrieval

    Science.gov (United States)

    Wapenaar, Kees; Thorbecke, Jan; van der Neut, Joost

    2016-04-01

    Green's theorem plays a fundamental role in a diverse range of wavefield imaging applications, such as holographic imaging, inverse scattering, time-reversal acoustics and interferometric Green's function retrieval. In many of those applications, the homogeneous Green's function (i.e. the Green's function of the wave equation without a singularity on the right-hand side) is represented by a closed boundary integral. In practical applications, sources and/or receivers are usually present only on an open surface, which implies that a significant part of the closed boundary integral is by necessity ignored. Here we derive a homogeneous Green's function representation for the common situation that sources and/or receivers are present on an open surface only. We modify the integrand in such a way that it vanishes on the part of the boundary where no sources and receivers are present. As a consequence, the remaining integral along the open surface is an accurate single-sided representation of the homogeneous Green's function. This single-sided representation accounts for all orders of multiple scattering. The new representation significantly improves the aforementioned wavefield imaging applications, particularly in situations where the first-order scattering approximation breaks down.

  12. A single-sided representation for the homogeneous Green's function of a unified scalar wave equation.

    Science.gov (United States)

    Wapenaar, Kees

    2017-06-01

    A unified scalar wave equation is formulated, which covers three-dimensional (3D) acoustic waves, 2D horizontally-polarised shear waves, 2D transverse-electric EM waves, 2D transverse-magnetic EM waves, 3D quantum-mechanical waves and 2D flexural waves. The homogeneous Green's function of this wave equation is a combination of the causal Green's function and its time-reversal, such that their singularities at the source position cancel each other. A classical representation expresses this homogeneous Green's function as a closed boundary integral. This representation finds applications in holographic imaging, time-reversed wave propagation and Green's function retrieval by cross correlation. The main drawback of the classical representation in those applications is that it requires access to a closed boundary around the medium of interest, whereas in many practical situations the medium can be accessed from one side only. Therefore, a single-sided representation is derived for the homogeneous Green's function of the unified scalar wave equation. Like the classical representation, this single-sided representation fully accounts for multiple scattering. The single-sided representation has the same applications as the classical representation, but unlike the classical representation it is applicable in situations where the medium of interest is accessible from one side only.

  13. The potential for increased power from combining P-values testing the same hypothesis.

    Science.gov (United States)

    Ganju, Jitendra; Julie Ma, Guoguang

    2017-02-01

    The conventional approach to hypothesis testing for formal inference is to prespecify a single test statistic thought to be optimal. However, we usually have more than one test statistic in mind for testing the null hypothesis of no treatment effect but we do not know which one is the most powerful. Rather than relying on a single p-value, combining p-values from prespecified multiple test statistics can be used for inference. Combining functions include Fisher's combination test and the minimum p-value. Using randomization-based tests, the increase in power can be remarkable when compared with a single test and Simes's method. The versatility of the method is that it also applies when the number of covariates exceeds the number of observations. The increase in power is large enough to prefer combined p-values over a single p-value. The limitation is that the method does not provide an unbiased estimator of the treatment effect and does not apply to situations when the model includes treatment by covariate interaction.

  14. THE ROLE OF VALUE AT RISK IN THE MANAGEMENT OF ASSET AND LIABILITIES

    Directory of Open Access Journals (Sweden)

    Petria Nicolae

    2012-12-01

    Full Text Available ALM is the management of risk at enterprise level, the models used in ALM can be static or dynamic: single period-static models, multiple period static model, single period stochastic model, multi period stochastic model. While single period-static don't incorporate the dynamic of the economical changes the multiple period-static models are an extension of the single period-static model, the most common used are multi-period stochastic which model the evolution of financial series in time and the assets and liabilities using different types of probability distributions (Student, GED. Highly correlated with ALM is the Value at Risk which can be used as and function to be minimized in ALM models. In the Value at Risk methodology the estimation models are classified as: parametric, nonparametric, semi-parametric; we present the parametric models (GARCH models used in Value at Risk and the connections that can be established between ALM models and Value at Risk. We present the Conditional Value-at-risk and offer and example on how to calculate CVaR .

  15. Early detection of lung function decrements in children and adolescents with cystic fibrosis using new reference values.

    Science.gov (United States)

    Zacharasiewicz, Angela; Renner, Sabine; Haderer, Flora; Weber, Michael; Dehlink, Eleonore; Szepfalusi, Zsolt; Frischer, Thomas

    2017-08-01

    Interpretation of lung function values in children with cystic fibrosis (CF) depends on the applied reference values. We hypothesize that differences between the new global lung function initiative (GLI) values and the formerly used Zapletal et al. values produce significantly different clinical results. We analyzed 3719 lung function measurements of 108 children and adolescents (n = 54 male; aged 6-18 years) with CF treated between September 1991 and July 2009. Data were analyzed in milliliters (ml) and % predicted (pred.) and interpreted using Zapletal and GLI reference values. Applying GLI compared to Zapletal resulted in significantly lower mean forced expiratory volume in 1s (FEV1)% pred. Zapletal 86.6% (SD 20.6), GLI 79.9% (SD 20.3) and 32% (n = 497/1543) were misclassified as normal when using Zapletal. Despite showing no overall differences in FEV1 and forced vital capacity (FVC) between concomitant Pseudomonas detection (PA+) in n = 938 and Pseudomonas negative (PA-) (n = 2781) using either reference PA+ resulted in lower FEV1 and FVC values with increasing age; however, measurement of small airway obstruction with forced expiratory flow at 75% of FVC (FEF75) values - available for Zapletal -showed significant differences. Reassurance regarding lung function when using old reference values may occur with potential clinical significance. Discrepancies in lung function interpretation underline the importance of using uniform and best available reference values.

  16. The cerebral blood flow measurement without absolute input function value for PET O-15 injection method

    International Nuclear Information System (INIS)

    Matsuda, Tadashige

    2004-01-01

    This paper shows the method of the measurement for the region of interest's (ROI's) cerebral blood flow (CBF) using PET data and the input function without the absolute density value of the radio activity. The value of the input function and the output function are fixed from the clinical data by regression analysis. The input function and the output function are transformed by the Fourier transform. The transfer function of the differential equation of the compartment model is got by these Fourier transforms. The CBF can be estimated by the transfer function regression analysis. Results are compared between the proposal and conventional methods. (author)

  17. Assessment of Single European Sky Implementation in the Functional Airspace Block Central Europe

    Directory of Open Access Journals (Sweden)

    Tomislav Mihetec

    2017-12-01

    implementation is performed through sub-regional grouping of Air Navigation Service Providers in a form of Functional Airspace Blocks. This paper analyses the level of implementation of ATM-related projects in the Functional Airspace Block Central Europe and their relation to other Functional Airspace Blocks defined in Europe. From this paper it is obvious that even though the planning of Single European Sky projects is based on the collaborative implementation of Functional Airspace Block level, the real implementation is fragmented and based on national levels.

  18. Management by the value of enterprise

    Directory of Open Access Journals (Sweden)

    M. V. Zenkinа

    2017-01-01

    Full Text Available The management of the enterprise's value is largely aimed at increasing the investment attractiveness of the enterprise. The search for new methods and techniques for managing the property complex faces a number of problems that are a promise of developing scientific approaches to the development of new progressive methods of making managerial decisions. The article considers alternative options for improving the quality of enterprise management and suggests the direction of improving the organization’s cost management system. A number of limiting factors, which allowed the author to determine the target indicators of the presented model, determines the presented objective function of enterprise value. It is permissible to change and expand the composition of the indicators and the approaches used to assess the value of the enterprise. The recommended model allows determining the reserves of increasing the efficiency of the enterprise, affecting the value of the property complex. Dependence of the singled out evaluation criteria and the targets of strategies for increasing the value of enterprises is indicated. The main stages of the enterprise value management process are considered as a single concept of increasing the current value of the organization. The characteristic of the concept of management aimed at creating valueValue Based Management (VBM is presented. The main principles of VBM aimed at qualitative improvement of strategic and operational decisions at all levels of management of the organization are singled out. Article considers the technology of introducing a cost management system based on the example of a construction organization. The main stages of enterprise cost management aimed at long-term sustainable growth in the value of the organization are identified. Particular attention is paid to the stages of analysis of the contribution of production and management units to the total value of the enterprise and the

  19. Maximum Principles and Boundary Value Problems for First-Order Neutral Functional Differential Equations

    Directory of Open Access Journals (Sweden)

    Domoshnitsky Alexander

    2009-01-01

    Full Text Available We obtain the maximum principles for the first-order neutral functional differential equation where , and are linear continuous operators, and are positive operators, is the space of continuous functions, and is the space of essentially bounded functions defined on . New tests on positivity of the Cauchy function and its derivative are proposed. Results on existence and uniqueness of solutions for various boundary value problems are obtained on the basis of the maximum principles.

  20. Computation of covex bounds for present value functions with random payments

    NARCIS (Netherlands)

    Ahcan, A.; Darkiewicz, G.; Goovaerts, M.J.; Hoedemakers, T.

    2006-01-01

    In this contribution we study the distribution of the present value function of a series of random payments in a stochastic financial environment. Such distributions occur naturally in a wide range of applications within fields of insurance and finance. We obtain accurate approximations by

  1. Effects of a preovulatory single low dose of mifepristone on ovarian function

    NARCIS (Netherlands)

    van der Stege, Jolande G.; Pahl-van Beest, Elske H.; Beerthuizen, Rob J. C. M.; van Lunsen, Rik H. W.; Scholten, Piet C.; Bogchelman, Dick H.

    Objectives To investigate the effect of a single low dose of mifepristone on ovarian function, when administered in the preovulatory period. Methods Healthy women with regular menstrual cycles were studied during two consecutive menstrual cycles. Either mifepristone or placebo was given in a

  2. Targeting a single function of the multifunctional matrix metalloprotease MT1-MMP

    DEFF Research Database (Denmark)

    Ingvarsen, Signe; Porse, Astrid; Erpicum, Charlotte

    2013-01-01

    and pathological events, has been complicated by the lack of specific inhibitors and the fact that some of the potent MMPs are multifunctional enzymes. These factors have also hampered the setup of therapeutic strategies targeting MMP activity. A tempting target is the membrane-associated MT1-MMP, which has well......-documented importance in matrix degradation but which takes part in more than one pathway in this regard. In this report, we describe the selective targeting of a single function of this enzyme by means of a specific monoclonal antibody against MT1-MMP, raised in an MT1-MMP knock-out mouse. The antibody blocks...... matrix in vitro, as well as in lymphatic vessel sprouting assayed ex vivo. This is the first example of the complete inactivation of a single function of a multifunctional MMP and the use of this strategy to pursue its role....

  3. Functional and magnetic resonance imaging evaluation after single-tendon rotator cuff reconstruction

    DEFF Research Database (Denmark)

    Knudsen, H B; Gelineck, J; Søjbjerg, Jens Ole

    1999-01-01

    The aim of this study was to investigate tendon integrity after surgical repair of single-tendon rotator cuff lesions. In 31 patients, 31 single-tendon repairs were evaluated. Thirty-one patients were available for clinical assessment and magnetic resonance imaging (MRI) at follow-up. A standard...... series of MR images was obtained for each. The results of functional assessment were scored according to the system of Constant. According to MRI evaluation, 21 (68%) patients had an intact or thinned rotator cuff and 10 (32%) had recurrence of a full-thickness cuff defect at follow-up. Patients...... with an intact or thinned rotator cuff had a median Constant score of 75.5 points; patients with a full-thickness cuff defect had a median score of 62 points. There was no correlation between tendon integrity on postoperative MR images and functional outcome. Patients with intact or thinned cuffs did not have...

  4. A Riesz Representation Theorem for the Space of Henstock Integrable Vector-Valued Functions

    Directory of Open Access Journals (Sweden)

    Tomás Pérez Becerra

    2018-01-01

    Full Text Available Using a bounded bilinear operator, we define the Henstock-Stieltjes integral for vector-valued functions; we prove some integration by parts theorems for Henstock integral and a Riesz-type theorem which provides an alternative proof of the representation theorem for real functions proved by Alexiewicz.

  5. Effect of a functional monomer (MDP) on the enamel bond durability of single-step self-etch adhesives.

    Science.gov (United States)

    Tsuchiya, Kenji; Takamizawa, Toshiki; Barkmeier, Wayne W; Tsubota, Keishi; Tsujimoto, Akimasa; Berry, Thomas P; Erickson, Robert L; Latta, Mark A; Miyazaki, Masashi

    2016-02-01

    The present study aimed to determine the effect of the functional monomer, 10-methacryloxydecyl dihydrogen phosphate (MDP), on the enamel bond durability of single-step self-etch adhesives through integrating fatigue testing and long-term water storage. An MDP-containing self-etch adhesive, Clearfil Bond SE ONE (SE), and an experimental adhesive, MDP-free (MF), which comprised the same ingredients as SE apart from MDP, were used. Shear bond strength (SBS) and shear fatigue strength (SFS) were measured with or without phosphoric acid pre-etching. The specimens were stored in distilled water for 24 h, 6 months, or 1 yr. Although similar SBS and SFS values were obtained for SE with pre-etching and for MF after 24 h of storage in distilled water, SE with pre-etching showed higher SBS and SFS values than MF after storage in water for 6 months or 1 yr. Regardless of the pre-etching procedure, SE showed higher SBS and SFS values after 6 months of storage in distilled water than after 24 h or 1 yr. To conclude, MDP might play an important role in enhancing not only bond strength but also bond durability with respect to repeated subcritical loading after long-term water storage. © 2015 Eur J Oral Sci.

  6. An efficient route towards the covalent functionalization of single walled carbon nanotubes

    International Nuclear Information System (INIS)

    Kakade, Bhalchandra A.; Pillai, Vijayamohanan K.

    2008-01-01

    A simple and efficient method of chemical functionalization of both single and multiwalled carbon nanotubes has been discussed to give enhanced water solubility by rapidly and efficiently generating an appreciable amount of hydrophilic functional groups using microwave radiation. Surface functionalization containing more than 30 wt% of oxygen has been achieved, resulting into solubility of 2-5 mg/mL. Further covalent functionalization of such soluble SWNTs provides a remarkable degree of aniline functionalization through amidation, where the formation of polyaniline has been avoided. Functionalization of SWNTs is confirmed by techniques like electron microscopy, Fourier transform infrared spectroscopy, thermogravimetry, Raman spectroscopy, cyclic voltammetry and impedance spectroscopy. Electrochemical analysis suggests an enhanced double layer capacitance (∼110 F/g) of nanotubes after microwave treatment. Aniline functionalization of SWNTs shows possible variations on the nanotube topography with concomitant formation of a dynamic polymer layer on the nanotube surface

  7. Orbital and total atomic momentum expectation values with Roothaan-Hartree-Fock wave functions

    International Nuclear Information System (INIS)

    De La Vega, J.M.G.; Miguel, B.

    1993-01-01

    Orbital and total momentum expectation values are computed using the Roothaan-Hartree-Fock wave functions of Clementi and Roetti. These values are calculated analytically and may be used to study the quality of basis sets. Tabulations for ground and excited states of atoms from Z = 2 to Z = 54 are presented. 23 refs., 1 tab

  8. Measurement of the infrared optical constants for spectral modeling: n and k values for (NH4)2SO4 via single-angle reflectance and ellipsometric methods

    Energy Technology Data Exchange (ETDEWEB)

    Blake, Thomas A.; Brauer, Carolyn S.; Kelly-Gorham, Molly Rose K.; Burton, Sarah D.; Bliss, Mary; Myers, Tanya L.; Johnson, Timothy J.; Tiwald, Thomas E.

    2017-05-05

    The optical constants n and k can be used to model infrared spectra, including refraction, absorption, reflectance, and emissivity, but obtaining reliable values for solid materials (pure or otherwise) presents a challenge: In the past, the best results for n and k have been obtained from bulk, homogeneous materials, free of defects. That is, materials where the Fresnel equations are operant since there is no light scattering. Since it is often not possible to obtain a pure macroscopic (crystalline) material, it may be possible to press the material into a (uniform, void-free) disk. We have recently been able to do this with ammonium sulfate powder and then measured the n & k values via two independent methods: 1) Ellipsometry - which measures the changes in amplitude and phase of light reflected from the material of interest as a function of wavelength and angle of incidence, and 2) Single angle specular reflectance with an FT spectrometer using a specular reflectance device within an FT instrument which measures the change in amplitude of light reflected from the material of interest as a function of wavelength and angle of incidence over a wide wavelength range. The quality of the derived n & k values was tested by generating the reflectance spectra of the pellet and comparing to the calculated to measured reflectance spectra of the pure material which has been previously published. The comparison to literature values showed good accuracy and good agreement, indicating promise to measure other materials by such methods.

  9. The Value of Reflective: Functioning within an Academic Therapeutic Nursery.

    Science.gov (United States)

    LaLonde, Mary M; Dreier, Mona; Aaronson, Gayle; O'Brien, John

    2015-01-01

    The self begins as a social self and is dependent on the other and the self-other relationship. Furthermore, shortly after birth, the intersubjective self is nurtured and sustained by the reciprocal interactions with the significant other. Recent research suggests that the significant other's reciprocity depends on his or her capacity for mentalization, and this reflective functioning capacity influences not only the child's developing sense of I, other, and we, but also his or her developing attachment pattern. Several studies have demonstrated that parental reflective functioning can be improved with intervention, and enhancing parental reflective functioning can lead to a more secure attachment pattern and better outcomes for the child and parent. Therefore, intervention with toddlers and their families requires us to consider this dynamic two-person psychology. In this paper, we describe an academic parent-child nursery program aimed at enhancing parental reflective functioning. A clinical example from the collaborative treatment of a mother and her two-year-old will demonstrate how reflective functioning can be enhanced in the parent-child dyad and lead to a more secure parent-child relationship. We will also discuss the value of reflective functioning to the interdisciplinary team and how we dealt with countertransference issues that arose during the treatment.

  10. Esthetic or Functional, Saccharine or Shocking? An Editor Looks at Values in Children's Books.

    Science.gov (United States)

    Giblin, James Cross

    1977-01-01

    Discusses artistic or esthetic, social and cultural, functional, and commercial values looked for by children's book editors in selecting and publishing manuscripts. Also reviews changes in social and cultural values as shown by children's books published in 1947, 1957, and 1967. (GT)

  11. Fragmentation of single-particle states in deformed nuclei

    International Nuclear Information System (INIS)

    Malov, L.A.; Soloviev, V.G.

    1975-01-01

    Fragmentation of single-particle states on levels of deformed nuclei is studied on the example of 239 U and 169 Er nuclei in the framework of the model taking into consideration the interaction of quasiparticles with phonons. The dependence of fragmentation on the Fermi surface is considered from the viewpoint of single-particle levels. It is shown that in the distribution of single-particle strength functions a second maximum appears together with the large asymmetry maximum at high-energy excitation, and the distribution has a long ''tail''. A semimicroscopic approach is proposed for calculating the neutron strength functions. The following values of the strength functions are obtained: for sub(239)U-Ssub(0)sup(cal)=1.2x10sup(-4), Ssub(1)sup(cal)=2.7x10sub(-4) and for sub(169)Er-Ssub(0)sup(cal)=1.10sup(-4), Ssub(1)sup(cal)=1.2x10sup(-4)

  12. Neutron transmission of single-crystal sapphire filters

    International Nuclear Information System (INIS)

    Adib, M.; Kilany, M.; Habib, N.; Fathallah, M.

    2005-01-01

    An additive formula is given that permits the calculation of the nuclear capture, thermal diffuse and Bragg scattering cross-sections as a function of sapphire temperature and crystal parameters. We have developed a computer program that allows calculations of the thermal neutron transmission for the sapphire rhombohedral structure and its equivalent trigonal structure. The calculated total cross-section values and effective attenuation coefficient for single-crystalline sapphire at different temperatures are compared with measured values. Overall agreement is indicated between the formula fits and experimental data. We discuss the use of sapphire single crystal as a thermal neutron filter in terms of the optimum crystal thickness, mosaic spread, temperature, cutting plane and tuning for efficient transmission of thermal-reactor neutrons. (author)

  13. Effect of single x-irradiation on glucocorticoid function of adrenal glands of adult and old rats

    International Nuclear Information System (INIS)

    Gorban', Je.M.; Topol'nyikova, N.V.

    2001-01-01

    The peculiarities of short-term (1 h, 1 day) adrenal glucocorticoid function in adult and old rats after single x-irradiation at different doses was studied. changes in the glucocorticoid function of the adrenal glands at studied terms after single x-irradiation at used doses were observed in adult but not in old animals. This testifies to an age-related decrease in the range of adaptive possibilities of this link of the organism adaptive system to x-irradiation effects

  14. Functionalized single walled carbon nanotubes as template for water storage device

    Energy Technology Data Exchange (ETDEWEB)

    Paul, Sanjib; Taraphder, Srabani, E-mail: srabani@chem.iitkgp.ernet.in

    2016-11-10

    Single walled carbon nanotubes, endohedrally functionalized with a protonated/unprotonated carboxylic acid group, are examined as potential templates for water storage using classical molecular dynamics simulation studies. Following a spontaneous entry of water molecules into the core of model functionalized carbon nanotubes (FCNTs), a large fraction of water molecules are found to be trapped inside FCNTs of lengths 50 and 100 Å. Only water molecules near the two open ends of the nanotube are exchanged with the bulk solvent. The residence times of water molecules inside FCNTs are investigated by varying the length of the tube, the length of suspended functional group and the protonation state of the carboxylic acid group. Favorable energetic interactions between the functional group and water, assisted by a substantial gain in rotational entropy, are found to compensate for the entropy loss resulting from restricted translational diffusion of trapped water molecules.

  15. Effects of single doses of X-rays on renal function in the pig after the irradiation of both kidneys

    International Nuclear Information System (INIS)

    Robbins, M.E.C.; Hopewell, J.W.

    1988-01-01

    Irradiation of a single kidney in the pig with relatively low doses of X-rays, in the order of 8 Gy, produces a pronounced reduction in both glomerular filtration rate (GFR) and effective renal plasma flow (ERPF). This apparent high radiosensitivity may be due, in part, to the compensatory hypertrophy displayed by the contralateral unirradiated kidney. This could suppress any potential for recovery by the irradiated kidney. To test this hypothesis, both kidneys of 14-week-old Large White pigs were sequentially irradiated with single doses of 250 kV X-rays, in the range 8.8 to 12.6 Gy. Two weeks after irradiation, GFR and ERPF increased markedly in all irradiated kidneys; levels then declined in a dose-dependent manner. Following a dose of 8.8 Gy renal haemodynamics returned to control values within 4 weeks of irradiation. After higher doses, GFR and ERPF decreased markedly and remained below control values up to 24 weeks after irradiation. At all doses the mean functional status of irradiated kidneys in animals in which both kidneys were irradiated was significantly greater than that previously observed in the irradiated kidney of pigs in which only one kidney was irradiated. The findings support the above hypothesis, and indicate that individual kidneys in the same animal may differ in their response to a similar nephrotoxic insult. 35 refs.; 6 figs.; 2 tabs

  16. Age-related normal structural and functional ventricular values in cardiac function assessed by magnetic resonance

    International Nuclear Information System (INIS)

    Fiechter, Michael; Gaemperli, Oliver; Kaufmann, Philipp A; Fuchs, Tobias A; Gebhard, Catherine; Stehli, Julia; Klaeser, Bernd; Stähli, Barbara E; Manka, Robert; Manes, Costantina; Tanner, Felix C

    2013-01-01

    The heart is subject to structural and functional changes with advancing age. However, the magnitude of cardiac age-dependent transformation has not been conclusively elucidated. This retrospective cardiac magnetic resonance (CMR) study included 183 subjects with normal structural and functional ventricular values. End systolic volume (ESV), end diastolic volume (EDV), and ejection fraction (EF) were obtained from the left and the right ventricle in breath-hold cine CMR. Patients were classified into four age groups (20–29, 30–49, 50–69, and ≥70 years) and cardiac measurements were compared using Pearson’s rank correlation over the four different groups. With advanced age a slight but significant decrease in ESV (r=−0.41 for both ventricles, P<0.001) and EDV (r=−0.39 for left ventricle, r=−0.35 for right ventricle, P<0.001) were observed associated with a significant increase in left (r=0.28, P<0.001) and right (r=0.27, P<0.01) ventricular EF reaching a maximal increase in EF of +8.4% (P<0.001) for the left and +6.1% (P<0.01) for the right ventricle in the oldest compared to the youngest patient group. Left ventricular myocardial mass significantly decreased over the four different age groups (P<0.05). The aging process is associated with significant changes in left and right ventricular EF, ESV and EDV in subjects with no cardiac functional and structural abnormalities. These findings underline the importance of using age adapted values as standard of reference when evaluating CMR studies

  17. The 64-MSCT study of relationship between renal corticomedullary differentiation, contrast between renal cortex and medulla, renal cortex and medulla CT peak value with the single renal function in hydronephrotic kidney

    International Nuclear Information System (INIS)

    Wang Yunhua; Hou Weiwei; Liu Ruihong; He Jianjun; Zhi Ke

    2009-01-01

    Objective: To study 64-MSCT perfusion imaging features about renal corticomedullary differentiation, contrast between renal cortex and medulla (CMC), renal cortex and medulla CT peak value in normal and hydronephrotic kidneys, and to explore the relationship between them and the unilateral renal function. Methods: Thirty-six patients with obstructive nephrohydrosis underwent 64-MSCT perfusion scanning. The split renal glomerular filtration rates (GFR) of their kidneys were measured by SPECT renal dynamic imaging. The 72 kidneys were divided into groups of normal renal function group, mild and severe renal impairment groups according to GFR. Renal corticomedullary differentiation on CT images was graded as clear, obscure, part clear. The CT intensity of cortex and medulla was measured in order to calculate contrast between renal cortex and medulla (CMC). Using Pearson correlation test, the correlation between them and renal GFR were examined. Results: (1) In the 24 kidneys of normal group, all kidneys showed clear CMD. In the 21 kidneys of mild renal impairment group, 14 kidneys showed clear CMD, 2 showed obscure CMD and 5 showed part clear of CMD. In the 27 kidneys of severe renal impairment group, 7 kidneys showed clear CMD, 5 showed obscure CMD and 15 showed part clear of CMD. (2)The CMC of normal group was 0.62 ± 0.20, while it was 0.52 ± 0.14 and 0.37 ± 0.11 for mild renal impairment group and severe renal impairment group CMC respectively. The CMC had positive linear correlation with GFR (r=0.536,P<0.05). (3) The renal cortex and medulla CT peak value of normal group were (133 ± 22) and (104 ± 16) HU; The renal cortex and medulla CT peak value of mild renal impairment group were (91 ± 29) and (76 ± 25) HU; The renal cortex and medulla CT peak value of severe renal impairment group were (68 ± 24) and (57 ± 21) HU(F=42.76 and 32.68,P<0.05). The renal cortex and medulla CT peak value had positive linear correlation with GFR (r=0.672 and 0.623, P<0

  18. Investigation of the Functional Neuroanatomy of Single Word Reading and Its Development

    Science.gov (United States)

    Palmer, Erica D.; Brown, Timothy T.; Petersen, Steven E.; Schlaggar, Bradley L.

    2004-01-01

    An understanding of the processing underlying single word reading will provide insight into how skilled reading is achieved, with important implications for reading education and impaired reading. Investigation of the functional neuroanatomy of both the mature and the developing systems will be critical for reaching this understanding. To this…

  19. Congruence and functions of personal and cultural values: do my values reflect my culture's values?

    Science.gov (United States)

    Fischer, Ronald

    2006-11-01

    Two studies are described examining the correlation between self- and culture-referenced values at a culture level (Study 1) and correlation between self- and culture-referenced values and self-reported behavior at an individual level (Study 2). It is found that values related to individual-group relationships (embeddedness) and expression and experience of affective feelings and emotions (affective autonomy) are significantly correlated at a culture level. In Study 2, culture-referenced values are shown to correlate with behaviors attached to social norms, whereas self-rated values are found to correlate with behaviors that are not norm-governed. Implications for measurement of cultural values and cultural and cross-cultural research designs are discussed.

  20. Two Ranking Methods of Single Valued Triangular Neutrosophic Numbers to Rank and Evaluate Information Systems Quality

    Directory of Open Access Journals (Sweden)

    Samah Ibrahim Abdel Aal

    2018-03-01

    Full Text Available The concept of neutrosophic can provide a generalization of fuzzy set and intuitionistic fuzzy set that make it is the best fit in representing indeterminacy and uncertainty. Single Valued Triangular Numbers (SVTrN-numbers is a special case of neutrosophic set that can handle ill-known quantity very difficult problems. This work intended to introduce a framework with two types of ranking methods. The results indicated that each ranking method has its own advantage. In this perspective, the weighted value and ambiguity based method gives more attention to uncertainty in ranking and evaluating ISQ as well as it takes into account cut sets of SVTrN numbers that can reflect the information on Truth-membership-membership degree, false membership-membership degree and Indeterminacy-membership degree. The value index and ambiguity index method can reflect the decision maker's subjectivity attitude to the SVTrN- numbers.

  1. Critical values of the Yang-Yang functional in the quantum sine-Gordon model

    International Nuclear Information System (INIS)

    Lukyanov, Sergei L.

    2011-01-01

    The critical values of the Yang-Yang functional corresponding to the vacuum states of the sine-Gordon QFT in the finite-volume are studied. Two major applications are discussed: (i) generalization of Fendley-Saleur-Zamolodchikov relations to arbitrary values of the sine-Gordon coupling constant, and (ii) connection problem for a certain two-parameter family of solutions of the Painleve III equation.

  2. Protein single-model quality assessment by feature-based probability density functions.

    Science.gov (United States)

    Cao, Renzhi; Cheng, Jianlin

    2016-04-04

    Protein quality assessment (QA) has played an important role in protein structure prediction. We developed a novel single-model quality assessment method-Qprob. Qprob calculates the absolute error for each protein feature value against the true quality scores (i.e. GDT-TS scores) of protein structural models, and uses them to estimate its probability density distribution for quality assessment. Qprob has been blindly tested on the 11th Critical Assessment of Techniques for Protein Structure Prediction (CASP11) as MULTICOM-NOVEL server. The official CASP result shows that Qprob ranks as one of the top single-model QA methods. In addition, Qprob makes contributions to our protein tertiary structure predictor MULTICOM, which is officially ranked 3rd out of 143 predictors. The good performance shows that Qprob is good at assessing the quality of models of hard targets. These results demonstrate that this new probability density distribution based method is effective for protein single-model quality assessment and is useful for protein structure prediction. The webserver of Qprob is available at: http://calla.rnet.missouri.edu/qprob/. The software is now freely available in the web server of Qprob.

  3. High performance dendrimer functionalized single-walled carbon nanotubes field effect transistor biosensor for protein detection

    Science.gov (United States)

    Rajesh, Sharma, Vikash; Puri, Nitin K.; Mulchandani, Ashok; Kotnala, Ravinder K.

    2016-12-01

    We report a single-walled carbon nanotube (SWNT) field-effect transistor (FET) functionalized with Polyamidoamine (PAMAM) dendrimer with 128 carboxyl groups as anchors for site specific biomolecular immobilization of protein antibody for C-reactive protein (CRP) detection. The FET device was characterized by scanning electron microscopy and current-gate voltage (I-Vg) characteristic studies. A concentration-dependent decrease in the source-drain current was observed in the regime of clinical significance, with a detection limit of ˜85 pM and a high sensitivity of 20% change in current (ΔI/I) per decade CRP concentration, showing SWNT being locally gated by the binding of CRP to antibody (anti-CRP) on the FET device. The low value of the dissociation constant (Kd = 0.31 ± 0.13 μg ml-1) indicated a high affinity of the device towards CRP analyte arising due to high anti-CRP loading with a better probe orientation on the 3-dimensional PAMAM structure.

  4. Incremental value of regional wall motion analysis immediately after exercise for the detection of single-vessel coronary artery disease. Study by separate acquisition, dual-isotope ECG-gated single-photon emission computed tomography

    International Nuclear Information System (INIS)

    Yoda, Shunichi; Sato, Yuichi; Matsumoto, Naoya; Tani, Shigemasa; Takayama, Tadateru; Uchiyama, Takahisa; Saito, Satoshi

    2005-01-01

    Although the detection of wall motion abnormalities gives incremental value to myocardial perfusion single-photon emission computed tomography (SPECT) in the diagnosis of extensive coronary artery disease (CAD) and high-grade single-vessel CAD, whether or not it is useful in the diagnosis of mild, single-vessel CAD has not been studied previously. Separate acquisition, dual isotope electrocardiogram (ECG)-gated SPECT was performed in 97 patients with a low likelihood of CAD (Group 1) and 46 patients with single-vessel CAD (Group 2). Mild CAD was defined by stenosis of 50-75% (Group 2a, n=22) and moderate to severe CAD was defined by stenosis ≥76% (Group 2b, n=24). Myocardial perfusion and wall motion were graded by a 5 point-scale, 20-segment model. The sensitivity of myocardial perfusion alone was 50% for Group 2a, 83% for Group 2b and 67% for Group 2 as a whole. The overall specificity was 90%. When the wall motion analysis was combined, the sensitivity was increased to 82% in Group 2a and 92% in Group 2b. The ability to detect a wall motion abnormality immediately after exercise gives incremental diagnostic value to myocardial perfusion SPECT in the identification of mild, single-vessel CAD. (author)

  5. Compact composition operators on real Banach spaces of complex-valued bounded Lipschitz functions

    Directory of Open Access Journals (Sweden)

    Davood Alimohammadi

    2014-10-01

    Full Text Available We characterize compact composition operators on real Banachspaces of complex-valued bounded Lipschitz functions on metricspaces, not necessarily compact, with Lipschitz involutions anddetermine their spectra.

  6. An interactive algorithm for identifying multiattribute measurable value functions based on finite-order independence of structural difference

    International Nuclear Information System (INIS)

    Tamura, Hiroyuki; Hikita, Shiro

    1985-01-01

    In this paper, we develop an interactive algorithm for identifying multiattribute measurable value functions based on the concept of finite-order independence of structural difference. This concept includes Dyer and Sarin's weak difference independence as special cases. The algorithm developed is composed of four major parts: 1) formulation of the problem 2) assessment of normalized conditional value functions and structural difference functions 3) assessment of corner values 4) assessment of the order of independence of structural difference and selection of the model. A hypothetical numerical example of a trade-off analysis for siting a nuclear power plant is included. (author)

  7. Single walled carbon nanotubes functionally adsorbed to biopolymers for use as chemical sensors

    Science.gov (United States)

    Johnson, Jr., Alan T.; Gelperin, Alan [Princeton, NJ; Staii, Cristian [Madison, WI

    2011-07-12

    Chemical field effect sensors comprising nanotube field effect devices having biopolymers such as single stranded DNA functionally adsorbed to the nanotubes are provided. Also included are arrays comprising the sensors and methods of using the devices to detect volatile compounds.

  8. VALUING BENEFITS FROM WATER QUALITY IMPROVEMENTS USING KUHN TUCKER MODEL - A COMPARATIVE ANALYSIS ON UTILITY FUNCTIONAL FORMS-

    Science.gov (United States)

    Okuyama, Tadahiro

    Kuhn-Tucker model, which has studied in recent years, is a benefit valuation technique using the revealed-preference data, and the feature is to treatvarious patterns of corner solutions flexibly. It is widely known for the benefit calculation using the revealed-preference data that a value of a benefit changes depending on a functional form. However, there are little studies which examine relationship between utility functions and values of benefits in Kuhn-Tucker model. The purpose of this study is to analysis an influence of the functional form to the value of a benefit. Six types of utility functions are employed for benefit calculations. The data of the recreational activity of 26 beaches of Miyagi Prefecture were employed. Calculation results indicated that Phaneuf and Siderelis (2003) and Whitehead et al.(2010)'s functional forms are useful for benefit calculations.

  9. Total Variation Regularization for Functions with Values in a Manifold

    KAUST Repository

    Lellmann, Jan

    2013-12-01

    While total variation is among the most popular regularizers for variational problems, its extension to functions with values in a manifold is an open problem. In this paper, we propose the first algorithm to solve such problems which applies to arbitrary Riemannian manifolds. The key idea is to reformulate the variational problem as a multilabel optimization problem with an infinite number of labels. This leads to a hard optimization problem which can be approximately solved using convex relaxation techniques. The framework can be easily adapted to different manifolds including spheres and three-dimensional rotations, and allows to obtain accurate solutions even with a relatively coarse discretization. With numerous examples we demonstrate that the proposed framework can be applied to variational models that incorporate chromaticity values, normal fields, or camera trajectories. © 2013 IEEE.

  10. Total Variation Regularization for Functions with Values in a Manifold

    KAUST Repository

    Lellmann, Jan; Strekalovskiy, Evgeny; Koetter, Sabrina; Cremers, Daniel

    2013-01-01

    While total variation is among the most popular regularizers for variational problems, its extension to functions with values in a manifold is an open problem. In this paper, we propose the first algorithm to solve such problems which applies to arbitrary Riemannian manifolds. The key idea is to reformulate the variational problem as a multilabel optimization problem with an infinite number of labels. This leads to a hard optimization problem which can be approximately solved using convex relaxation techniques. The framework can be easily adapted to different manifolds including spheres and three-dimensional rotations, and allows to obtain accurate solutions even with a relatively coarse discretization. With numerous examples we demonstrate that the proposed framework can be applied to variational models that incorporate chromaticity values, normal fields, or camera trajectories. © 2013 IEEE.

  11. Dual-function photonic integrated circuit for frequency octo-tupling or single-side-band modulation.

    Science.gov (United States)

    Hasan, Mehedi; Maldonado-Basilio, Ramón; Hall, Trevor J

    2015-06-01

    A dual-function photonic integrated circuit for microwave photonic applications is proposed. The circuit consists of four linear electro-optic phase modulators connected optically in parallel within a generalized Mach-Zehnder interferometer architecture. The photonic circuit is arranged to have two separate output ports. A first port provides frequency up-conversion of a microwave signal from the electrical to the optical domain; equivalently single-side-band modulation. A second port provides tunable millimeter wave carriers by frequency octo-tupling of an appropriate amplitude RF carrier. The circuit exploits the intrinsic relative phases between the ports of multi-mode interference couplers to provide substantially all the static optical phases needed. The operation of the proposed dual-function photonic integrated circuit is verified by computer simulations. The performance of the frequency octo-tupling and up-conversion functions is analyzed in terms of the electrical signal to harmonic distortion ratio and the optical single side band to unwanted harmonics ratio, respectively.

  12. Understanding the value of plant diversity for ecosystem functioning through niche theory

    Science.gov (United States)

    Isbell, Forest; Purves, Drew W.; Loreau, Michel

    2016-01-01

    Biodiversity experiments have generated robust empirical results supporting the hypothesis that ecosystems function better when they contain more species. Given that ecosystems provide services that are valued by humans, this inevitably suggests that the loss of species from natural ecosystems could diminish their value. This raises two important questions. First, will experimental results translate into the real world, where species are being lost at an alarming rate? And second, what are the benefits and pitfalls of such valuation exercises? We argue that the empirical results obtained in experiments are entirely consistent with well-established theories of species coexistence. We then examine the current body of work through the lens of niche theory and highlight where closer links with theory could open up opportunities for future research. We argue that niche theory predicts that diversity–functioning relationships are likely to be stronger (and require more species) in the field than in simplified experimental settings. However, we caution that while many of the biological processes that promote coexistence can also generate diversity–function relationships, there is no simple mapping between the two. This implies that valuation exercises need to proceed with care. PMID:27928043

  13. Absence of even-integer ζ-function values in Euclidean physical quantities in QCD

    Science.gov (United States)

    Jamin, Matthias; Miravitllas, Ramon

    2018-04-01

    At order αs4 in perturbative quantum chromodynamics, even-integer ζ-function values are present in Euclidean physical correlation functions like the scalar quark correlation function or the scalar gluonium correlator. We demonstrate that these contributions cancel when the perturbative expansion is expressed in terms of the so-called C-scheme coupling αˆs which has recently been introduced in Ref. [1]. It is furthermore conjectured that a ζ4 term should arise in the Adler function at order αs5 in the MS ‾-scheme, and that this term is expected to disappear in the C-scheme as well.

  14. Value Creation and Value Claiming in Make-Or-Buy Decisions

    NARCIS (Netherlands)

    E. Verwaal (Ernst); W.J.M.I. Verbeke (Willem); H.R. Commandeur (Harry)

    2002-01-01

    textabstractTransaction value analysis (TVA) integrates the concepts of resource heterogeneity and transaction cost economics into a single framework, which emphasizes both value creation and value claiming in firms' vertical integration decisions. Using a TVA perspective, we develop hypotheses to

  15. Nucleon deep-inelastic structure functions in a quark model with factorizability assumptions

    International Nuclear Information System (INIS)

    Linkevich, A.D.; Skachkov, N.B.

    1979-01-01

    Formula for structure functions of deep-inelastic electron scattering on nucleon is derived. For this purpose the dynamic model of factorizing quark amplitudes is used. It has been found that with increase of Q 2 transferred pulse square at great values of x kinemastic variable the decrease of structure function values is observed. At x single values the increase of structure function values is found. The comparison With experimental data shows a good agreement of the model with experiment

  16. Single walled carbon nanotubes with functionally adsorbed biopolymers for use as chemical sensors

    Science.gov (United States)

    Johnson, Jr., Alan T

    2013-12-17

    Chemical field effect sensors comprising nanotube field effect devices having biopolymers such as single stranded DNA or RNA functionally adsorbed to the nanotubes are provided. Also included are arrays comprising the sensors and methods of using the devices to detect volatile compounds.

  17. Shedding light on protein folding, structural and functional dynamics by single molecule studies

    DEFF Research Database (Denmark)

    Bavishi, Krutika; Hatzakis, Nikos

    2014-01-01

    property of a population, single molecule measurements offer observation and quantification of the abundance, lifetime and function of multiple protein states. They also permit the direct observation of the transient and rarely populated intermediates in the energy landscape that are typically averaged out...

  18. Early subtropical forest growth is driven by community mean trait values and functional diversity rather than the abiotic environment.

    Science.gov (United States)

    Kröber, Wenzel; Li, Ying; Härdtle, Werner; Ma, Keping; Schmid, Bernhard; Schmidt, Karsten; Scholten, Thomas; Seidler, Gunnar; von Oheimb, Goddert; Welk, Erik; Wirth, Christian; Bruelheide, Helge

    2015-09-01

    While functional diversity (FD) has been shown to be positively related to a number of ecosystem functions including biomass production, it may have a much less pronounced effect than that of environmental factors or species-specific properties. Leaf and wood traits can be considered particularly relevant to tree growth, as they reflect a trade-off between resources invested into growth and persistence. Our study focussed on the degree to which early forest growth was driven by FD, the environment (11 variables characterizing abiotic habitat conditions), and community-weighted mean (CWM) values of species traits in the context of a large-scale tree diversity experiment (BEF-China). Growth rates of trees with respect to crown diameter were aggregated across 231 plots (hosting between one and 23 tree species) and related to environmental variables, FD, and CWM, the latter two of which were based on 41 plant functional traits. The effects of each of the three predictor groups were analyzed separately by mixed model optimization and jointly by variance partitioning. Numerous single traits predicted plot-level tree growth, both in the models based on CWMs and FD, but none of the environmental variables was able to predict tree growth. In the best models, environment and FD explained only 4 and 31% of variation in crown growth rates, respectively, while CWM trait values explained 42%. In total, the best models accounted for 51% of crown growth. The marginal role of the selected environmental variables was unexpected, given the high topographic heterogeneity and large size of the experiment, as was the significant impact of FD, demonstrating that positive diversity effects already occur during the early stages in tree plantations.

  19. Resonances in a two-dimensional electron waveguide with a single δ-function scatterer

    International Nuclear Information System (INIS)

    Boese, Daniel; Lischka, Markus; Reichl, L. E.

    2000-01-01

    We study the conductance properties of a straight two-dimensional electron waveguide with an s-like scatterer modeled by a single δ-function potential with a finite number of modes. Even such a simple system exhibits interesting resonance phenomena. These resonances are explained in terms of quasibound states both by using a direct solution of the Schroedinger equation and by studying the Green's function of the system. Using the Green's function we calculate the survival probability as well as the power absorption, and show the influence of the quasibound states on these two quantities. (c) 2000 The American Physical Society

  20. A point-value enhanced finite volume method based on approximate delta functions

    Science.gov (United States)

    Xuan, Li-Jun; Majdalani, Joseph

    2018-02-01

    We revisit the concept of an approximate delta function (ADF), introduced by Huynh (2011) [1], in the form of a finite-order polynomial that holds identical integral properties to the Dirac delta function when used in conjunction with a finite-order polynomial integrand over a finite domain. We show that the use of generic ADF polynomials can be effective at recovering and generalizing several high-order methods, including Taylor-based and nodal-based Discontinuous Galerkin methods, as well as the Correction Procedure via Reconstruction. Based on the ADF concept, we then proceed to formulate a Point-value enhanced Finite Volume (PFV) method, which stores and updates the cell-averaged values inside each element as well as the unknown quantities and, if needed, their derivatives on nodal points. The sharing of nodal information with surrounding elements saves the number of degrees of freedom compared to other compact methods at the same order. To ensure conservation, cell-averaged values are updated using an identical approach to that adopted in the finite volume method. Here, the updating of nodal values and their derivatives is achieved through an ADF concept that leverages all of the elements within the domain of integration that share the same nodal point. The resulting scheme is shown to be very stable at successively increasing orders. Both accuracy and stability of the PFV method are verified using a Fourier analysis and through applications to the linear wave and nonlinear Burgers' equations in one-dimensional space.

  1. "Ico-Alone" single nocturnal exchange to initiate peritoneal dialysis in patients with residual renal function-Five year, single centre experience

    Directory of Open Access Journals (Sweden)

    T Jeloka

    2013-01-01

    Full Text Available We analyzed the outcome of incremental dialysis with single nocturnal icodextrin exchange peritoneal dialysis (PD as the initial treatment for end-stage kidney failure in patients who have significant residual renal function. All adult patients opting for PD as renal replacement therapy, having residual renal function, and urinary KT/V of 1.0 were offered incremental dialysis with single nocturnal icodextrin exchange as initial treatment. Adequacy of dialysis was calculated at 1, 3, and 6 months and then 6 monthly. Patients were shifted to conventional PD if short of adequacy or if clinically indicated. Median period on "Ico-alone," peritonitis, exit site infection rates, and patient survival, while on this protocol, were calculated. These outcomes were compared with the cohort of contemporary patients on conventional PD. Thirteen patients were initiated on "Ico-alone" dialysis between October 2006 and October 2011. The baseline characteristics were similar when compared with cohort of conventional PD patients, except urine volume, which was more in "Ico-alone" group (1265 ± 316 vs. 551 ± 504, P = 0.000. Total KT/V at 3 months (1.63 ± 0.6 vs. 1.7 ± 0.2, P = 0.6 and at 1 year (1.64 ± 0.5 vs. 1.53 ± 0.3, P = 0.6 was similar to the cohort of conventional PD patients. Median period on "Ico-alone" was 9.6 months. Peritonitis rate was 1 episode in 56.22 vs 25.29 patient-months and exit site infection was 1 episode in 56.2 vs 189.71 patient-months in "Ico-alone" and conventional group, respectively. Patient survival was 42.84 months in "Ico-alone′ vs 25.29 months in conventional dialysis ( P = 0.01. In conclusion, single icodextrin exchange offers adequate dialysis in patients with residual renal function (KT/V = 1 for a median period of 9 months.

  2. Maximum entropy formalism for the analytic continuation of matrix-valued Green's functions

    Science.gov (United States)

    Kraberger, Gernot J.; Triebl, Robert; Zingl, Manuel; Aichhorn, Markus

    2017-10-01

    We present a generalization of the maximum entropy method to the analytic continuation of matrix-valued Green's functions. To treat off-diagonal elements correctly based on Bayesian probability theory, the entropy term has to be extended for spectral functions that are possibly negative in some frequency ranges. In that way, all matrix elements of the Green's function matrix can be analytically continued; we introduce a computationally cheap element-wise method for this purpose. However, this method cannot ensure important constraints on the mathematical properties of the resulting spectral functions, namely positive semidefiniteness and Hermiticity. To improve on this, we present a full matrix formalism, where all matrix elements are treated simultaneously. We show the capabilities of these methods using insulating and metallic dynamical mean-field theory (DMFT) Green's functions as test cases. Finally, we apply the methods to realistic material calculations for LaTiO3, where off-diagonal matrix elements in the Green's function appear due to the distorted crystal structure.

  3. Does double-row rotator cuff repair improve functional outcome of patients compared with single-row technique? A systematic review.

    Science.gov (United States)

    DeHaan, Alexander M; Axelrad, Thomas W; Kaye, Elizabeth; Silvestri, Lorenzo; Puskas, Brian; Foster, Timothy E

    2012-05-01

    The advantage of single-row versus double-row arthroscopic rotator cuff repair techniques has been a controversial issue in sports medicine and shoulder surgery. There is biomechanical evidence that double-row techniques are superior to single-row techniques; however, there is no clinical evidence that the double-row technique provides an improved functional outcome. When compared with single-row rotator cuff repair, double-row fixation, although biomechanically superior, has no clinical benefit with respect to retear rate or improved functional outcome. Systematic review. The authors reviewed prospective studies of level I or II clinical evidence that compared the efficacy of single- and double-row rotator cuff repairs. Functional outcome scores included the American Shoulder and Elbow Surgeons (ASES) shoulder scale, the Constant shoulder score, and the University of California, Los Angeles (UCLA) shoulder rating scale. Radiographic failures and complications were also analyzed. A test of heterogeneity for patient demographics was also performed to determine if there were differences in the patient profiles across the included studies. Seven studies fulfilled our inclusion criteria. The test of heterogeneity across these studies showed no differences. The functional ASES, Constant, and UCLA outcome scores revealed no difference between single- and double-row rotator cuff repairs. The total retear rate, which included both complete and partial retears, was 43.1% for the single-row repair and 27.2% for the double-row repair (P = .057), representing a trend toward higher failures in the single-row group. Through a comprehensive literature search and meta-analysis of current arthroscopic rotator cuff repairs, we found that the single-row repairs did not differ from the double-row repairs in functional outcome scores. The double-row repairs revealed a trend toward a lower radiographic proven retear rate, although the data did not reach statistical significance. There

  4. Surface water retardation around single-chain polymeric nanoparticles: critical for catalytic function?

    Science.gov (United States)

    Stals, Patrick J M; Cheng, Chi-Yuan; van Beek, Lotte; Wauters, Annelies C; Palmans, Anja R A; Han, Songi; Meijer, E W

    2016-03-01

    A library of water-soluble dynamic single-chain polymeric nanoparticles (SCPN) was prepared using a controlled radical polymerisation technique followed by the introduction of functional groups, including probes at targeted positions. The combined tools of electron paramagnetic resonance (EPR) and Overhauser dynamic nuclear polarization (ODNP) reveal that these SCPNs have structural and surface hydration properties resembling that of enzymes.

  5. Measurement of ventricular function by ECG gating during atrial fibrillation

    International Nuclear Information System (INIS)

    Bacharach, S.L.; Green, M.V.; Bonow, R.O.; Findley, S.L.; Ostrow, H.G.; Johnston, G.S.

    1981-01-01

    The assumptions necessary to perform ECG-gated cardiac studies are seemingly not valid for patients in atrial fibrillation (AF). To evaluate the effect of AF on equilibrium gated scintigraphy, beat-by-beat measurements of left-ventricular function were made on seven subjects in AF (mean heart rate 64 bpm), using a high-efficiency nonimaging detector. The parameters evaluated were ejection fraction (EF), time to end-systole (TES), peak rates of ejection and filling (PER,PFR), and their times of occurrence (TPER, TPFR). By averaging together single-beat values of EF, PER, etc., it was possible to determine the true mean values of these parameters. The single-beam mean values were compared with the corresponding parameters calculated from one ECG-gated time-activity curve (TAC) obtained by superimposing all the single-beat TACs irrespective of their length. For this population with slow heart rates, we find that the values for EF, etc., produced from ECG-gated time-activity curves, are very similar to those obtained from the single-beat data. Thus use of ECG gating at low heart rates may allow reliable estimation of average cardiac function even in subjects with AF

  6. The neural basis of human social values: evidence from functional MRI.

    Science.gov (United States)

    Zahn, Roland; Moll, Jorge; Paiva, Mirella; Garrido, Griselda; Krueger, Frank; Huey, Edward D; Grafman, Jordan

    2009-02-01

    Social values are composed of social concepts (e.g., "generosity") and context-dependent moral sentiments (e.g., "pride"). The neural basis of this intricate cognitive architecture has not been investigated thus far. Here, we used functional magnetic resonance imaging while subjects imagined their own actions toward another person (self-agency) which either conformed or were counter to a social value and were associated with pride or guilt, respectively. Imagined actions of another person toward the subjects (other-agency) in accordance with or counter to a value were associated with gratitude or indignation/anger. As hypothesized, superior anterior temporal lobe (aTL) activity increased with conceptual detail in all conditions. During self-agency, activity in the anterior ventromedial prefrontal cortex correlated with pride and guilt, whereas activity in the subgenual cingulate solely correlated with guilt. In contrast, indignation/anger activated lateral orbitofrontal-insular cortices. Pride and gratitude additionally evoked mesolimbic and basal forebrain activations. Our results demonstrate that social values emerge from coactivation of stable abstract social conceptual representations in the superior aTL and context-dependent moral sentiments encoded in fronto-mesolimbic regions. This neural architecture may provide the basis of our ability to communicate about the meaning of social values across cultural contexts without limiting our flexibility to adapt their emotional interpretation.

  7. Liver function assessment using 99mTc-GSA single-photon emission computed tomography (SPECT)/CT fusion imaging in hilar bile duct cancer: A retrospective study.

    Science.gov (United States)

    Sumiyoshi, Tatsuaki; Shima, Yasuo; Okabayashi, Takehiro; Kozuki, Akihito; Hata, Yasuhiro; Noda, Yoshihiro; Kouno, Michihiko; Miyagawa, Kazuyuki; Tokorodani, Ryotaro; Saisaka, Yuichi; Tokumaru, Teppei; Nakamura, Toshio; Morita, Sojiro

    2016-07-01

    The objective of this study was to determine the utility of Tc-99m-diethylenetriamine-penta-acetic acid-galactosyl human serum albumin ((99m)Tc-GSA) single-photon emission computed tomography (SPECT)/CT fusion imaging for posthepatectomy remnant liver function assessment in hilar bile duct cancer patients. Thirty hilar bile duct cancer patients who underwent major hepatectomy with extrahepatic bile duct resection were retrospectively analyzed. Indocyanine green plasma clearance rate (KICG) value and estimated KICG by (99m)Tc-GSA scintigraphy (KGSA) and volumetric and functional rates of future remnant liver by (99m)Tc-GSA SPECT/CT fusion imaging were used to evaluate preoperative whole liver function and posthepatectomy remnant liver function, respectively. Remnant (rem) KICG (= KICG × volumetric rate) and remKGSA (= KGSA × functional rate) were used to predict future remnant liver function; major hepatectomy was considered unsafe for values liver were significantly higher than volumetric rates (median: 0.54 vs 0.46; P liver failure and mortality did not occur in the patients for whom hepatectomy was considered unsafe based on remKICG. remKGSA showed a stronger correlation with postoperative prothrombin time activity than remKICG. (99m)Tc-GSA SPECT/CT fusion imaging enables accurate assessment of future remnant liver function and suitability for hepatectomy in hilar bile duct cancer patients. Copyright © 2016 Elsevier Inc. All rights reserved.

  8. Choquet Integral of Fuzzy-Number-Valued Functions: The Differentiability of the Primitive with respect to Fuzzy Measures and Choquet Integral Equations

    Directory of Open Access Journals (Sweden)

    Zengtai Gong

    2014-01-01

    Full Text Available This paper deals with the Choquet integral of fuzzy-number-valued functions based on the nonnegative real line. We firstly give the definitions and the characterizations of the Choquet integrals of interval-valued functions and fuzzy-number-valued functions based on the nonadditive measure. Furthermore, the operational schemes of above several classes of integrals on a discrete set are investigated which enable us to calculate Choquet integrals in some applications. Secondly, we give a representation of the Choquet integral of a nonnegative, continuous, and increasing fuzzy-number-valued function with respect to a fuzzy measure. In addition, in order to solve Choquet integral equations of fuzzy-number-valued functions, a concept of the Laplace transformation for the fuzzy-number-valued functions in the sense of Choquet integral is introduced. For distorted Lebesgue measures, it is shown that Choquet integral equations of fuzzy-number-valued functions can be solved by the Laplace transformation. Finally, an example is given to illustrate the main results at the end of the paper.

  9. Threshold values of ankle dorsiflexion and gross motor function in 60 children with cerebral palsy

    DEFF Research Database (Denmark)

    Rasmussen, Helle M; Svensson, Joachim; Thorning, Maria

    2018-01-01

    Background and purpose - Threshold values defining 3 categories of passive range of motion are used in the Cerebral Palsy follow-Up Program to guide clinical decisions. The aim of this study was to investigate the threshold values by testing the hypothesis that passive range of motion in ankle...... dorsiflexion is associated with gross motor function and that function differs between the groups of participants in each category. Patients and methods - We analyzed data from 60 ambulatory children (aged 5-9 years) with spastic cerebral palsy. Outcomes were passive range of motion in ankle dorsiflexion...... with flexed and extended knee and gross motor function (Gait Deviation Index, Gait Variable Score of the ankle, peak dorsiflexion during gait, 1-minute walk, Gross Motor Function Measure, the Pediatric Quality of Life Inventory Cerebral Palsy Module, and Pediatric Outcomes Data Collection Instrument). Results...

  10. Dimensions of Family Functioning: Perspectives of Low-Income African American Single Parent Families

    Science.gov (United States)

    Mccreary, Linda L.; Dancy, Barbara L.

    2004-01-01

    Family functioning is influenced by socio-economic status, culture, family structure, and developmental stage, and is assessed primarily using instruments developed for middle-income European American two-parent families. These instruments may not validly assess low-income African American single-parent families. This qualitative study was…

  11. Effects of ageing on single muscle fibre contractile function following short-term immobilisation

    DEFF Research Database (Denmark)

    Hvid, Lars G; Ørtenblad, Niels; Aagaard, Per

    2011-01-01

    Very little attention has been given to the combined effect of healthy ageing and short-term disuse on the contractile function of human single muscle fibres. Therefore, the present study investigated the effects of 2 weeks of lower limb cast immobilisation (i.e. disuse) on selected contractile...

  12. Existence of solutions to differential inclusions with primal lower nice functions

    Directory of Open Access Journals (Sweden)

    Nora Fetouci

    2016-02-01

    Full Text Available We prove the existence of absolutely continuous solutions to the differential inclusion $$ \\dot{x}(t\\in F(x(t+h(t,x(t, $$ where F is an upper semi-continuous set-valued function with compact values such that $F(x(t\\subset \\partial f(x(t$ on [0,T], where f is a primal lower nice function, and h a single valued Caratheodory perturbation.

  13. Single-walled carbon nanotubes disturbed the immune and metabolic regulation function 13-weeks after a single intratracheal instillation

    Energy Technology Data Exchange (ETDEWEB)

    Park, Eun-Jung, E-mail: pejtoxic@hanmail.net [Myunggok Eye Research Institute, Konyang University, Daejeon 302-718 (Korea, Republic of); Hong, Young-Shick [Division of Food and Nutrition, Chonnam National University, Yongbong-Ro, Buk-Gu, Gwangju 500-757 (Korea, Republic of); Lee, Byoung-Seok [Toxicologic Pathology Center, Korea Institute of Toxicology, Daejeon (Korea, Republic of); Yoon, Cheolho [Seoul Center, Korea Basic Science Institute, Seoul 126-16 (Korea, Republic of); Jeong, Uiseok; Kim, Younghun [Department of Chemical Engineering, Kwangwoon University, Seoul 139-701 (Korea, Republic of)

    2016-07-15

    Due to their unique physicochemical properties, the potential health effects of single-walled carbon nanotubes (SWCNTs) have attracted continuous attention together with their extensive application. In this study, we aimed to identify local and systemic health effects following pulmonary persistence of SWCNTs. As expected, SWCNTs remained in the lung for 13 weeks after a single intratracheal instillation (50, 100, and 200 μg/kg). In the lung, the total number of cells and the percentages of lymphocytes and neutrophils significantly increased at 200 μg/kg compared to the control, and the Th1-polarized immune response was induced accompanying enhanced expression of tissue damage-related genes and increased release of chemokines. Additionally, SWCNTs enhanced the expression of antigen presentation-related proteins on the surface of antigen-presenting cells, however, maturation of dendritic cells was inhibited by their persistence. As compared to the control, a significant increase in the percentage of neutrophils and a remarkable decrease of BUN and potassium level were observed in the blood of mice treated with the highest dose. This was accompanied by the down-regulation of the expression of antigen presentation-related proteins on splenocytes. Moreover, protein and glucose metabolism were disturbed with an up-regulation of fatty acid β-oxidation. Taken together, we conclude that SWCNTs may induce adverse health effects by disturbing immune and metabolic regulation functions in the body. Therefore, careful application of SWCNTs is necessary for the enforcement of safety in nano-industries. - Highlights: • We evaluated local and systemic health effects following persistence of SWCNTs. • SWCNTs remained in the lung for 13 weeks after a single intratracheal instillation. • Th1-polarized immune response was induced in the lung. • The expression of antigen presentation-related proteins was altered. • Immune and metabolic regulation function were disturbed.

  14. On nonseparated three-point boundary value problems for linear functional differential equations

    Czech Academy of Sciences Publication Activity Database

    Rontó, András; Rontó, M.

    2011-01-01

    Roč. 2011, - (2011), s. 326052 ISSN 1085-3375 Institutional research plan: CEZ:AV0Z10190503 Keywords : functional-differential equation * three-point boundary value problem * nonseparated boundary condition Subject RIV: BA - General Mathematics Impact factor: 1.318, year: 2011 http://www.hindawi.com/journals/ aaa /2011/326052/

  15. A technique for combining neutron and gamma-ray data into a single assay value

    International Nuclear Information System (INIS)

    Pickrell, M.M.; Mercer, D.; Sharpe, T.J.

    1998-01-01

    The authors explored the potentials of using both neutron and gamma-ray measurements on a single item and combining these data into a single assay value. The purpose was to improve assay capability for sample matrices that are difficult to measure. They chose an empirical approach because they wanted to address difficult-to-measure items for which the assay problem is complex. They used the tomographic gamma scanner; a passive, high-efficiency neutron counter with add-a-source and multiplicity; and an active neutron, californium shuffler to obtain measurements. Twenty-four 200-L drums were measured with various matrices using all three machines. The matrices were chosen specifically to spain the difficult-to-measure assay problems for some or all of the instruments. For example, the authors measured a drum filled with concrete and another filled with metal. The data from these measurements were analyzed using the alternating conditional expectation algorithm, which is one of a class of generalized additive models. Other data fusion algorithms are also possible and are being explored. The intent was to find ways to combine the data that would reduce the matrix-induced measurement error

  16. The additive prognostic value of perfusion and functional data assessed by quantitative gated SPECT in women

    NARCIS (Netherlands)

    Y.G.C.J. America (Yves); J.J. Bax (Jeroen); H. Boersma (Eric); M. Stokkel (Marcel); E.E. van der Wall (Ernst)

    2009-01-01

    textabstractBackground: The aim of this study was to assess the prognostic value of technetium-99m tetrofosmin gated SPECT imaging in women using quantitative gated single photon emission computed tomography (SPECT) imaging. Methods: We followed 453 consecutive female patients. Average follow-up was

  17. Tunable top-down fabrication and functional surface coating of single-crystal titanium dioxide nanostructures and nanoparticles

    Science.gov (United States)

    Ha, Seungkyu; Janissen, Richard; Ussembayev, Yera Ye.; van Oene, Maarten M.; Solano, Belen; Dekker, Nynke H.

    2016-05-01

    Titanium dioxide (TiO2) is a key component of diverse optical and electronic applications that exploit its exceptional material properties. In particular, the use of TiO2 in its single-crystalline phase can offer substantial advantages over its amorphous and polycrystalline phases for existing and yet-to-be-developed applications. However, the implementation of single-crystal TiO2 has been hampered by challenges in its fabrication and subsequent surface functionalization. Here, we introduce a novel top-down approach that allows for batch fabrication of uniform high-aspect-ratio single-crystal TiO2 nanostructures with targeted sidewall profiles. We complement our fabrication approach with a functionalization strategy that achieves dense, uniform, and area-selective coating with a variety of biomolecules. This allows us to fabricate single-crystal rutile TiO2 nanocylinders tethered with individual DNA molecules for use as force- and torque-transducers in an optical torque wrench. These developments provide the means for increased exploitation of the superior material properties of single-crystal TiO2 at the nanoscale.Titanium dioxide (TiO2) is a key component of diverse optical and electronic applications that exploit its exceptional material properties. In particular, the use of TiO2 in its single-crystalline phase can offer substantial advantages over its amorphous and polycrystalline phases for existing and yet-to-be-developed applications. However, the implementation of single-crystal TiO2 has been hampered by challenges in its fabrication and subsequent surface functionalization. Here, we introduce a novel top-down approach that allows for batch fabrication of uniform high-aspect-ratio single-crystal TiO2 nanostructures with targeted sidewall profiles. We complement our fabrication approach with a functionalization strategy that achieves dense, uniform, and area-selective coating with a variety of biomolecules. This allows us to fabricate single-crystal rutile

  18. Functioning strategy study on control systems of large physical installations used with a digital computer

    International Nuclear Information System (INIS)

    Bel'man, L.B.; Lavrikov, S.A.; Lenskij, O.D.

    1975-01-01

    A criterion to evaluate the efficiency of a control system functioning of large physical installations by means of a control computer. The criteria are the object utilization factor and computer load factor. Different strategies of control system functioning are described, and their comparative analysis is made. A choice of such important parameters as sampling time and parameter correction time is made. A single factor to evaluate the system functioning efficiency is introduced and its dependence on the sampling interval value is given. Using diagrams attached, it is easy to find the optimum value of the sampling interval and the corresponding maximum value of the single efficiency factor proposed

  19. Value of selective MIP reconstructions of respiratory triggered 3D-TSE-MR cholangiography on a workstation versus standard MIP reconstructions and single-shot MRCP

    International Nuclear Information System (INIS)

    Schaible, R.; Textor, J.; Kreft, B.; Schild, H.; Neubrand, M.

    2001-01-01

    Comparison of anatomical visualisation and diagnostic value of selective MIP reconstructions of respiratory triggered 3D-TSE-MRCP versus standard MIP reconstructions and single-shot MRCP. Material and Methods: 50 patients with pancreaticobiliary disease were examined at 1.5 Tesla (ACS NT II, Philips Medical Systems) using a breath-hold single-shot (SS) and a respiratory triggered 3D-TSE-MRCP technique in 12 standard MIP projections. Additional selective MIP reconstructions with different slice thickness (2, 4, 10 cm) and projections were performed on a workstation. Visualization of the pancreaticobiliary system and the diagnostic value of the examinations were analysed. Results: Single-shot and 3D-TSE in standard projections showed comparable anatomical visualisation. On selective MIP reconstructions the biliary system (SS p [de

  20. Analysis and optimization with ecological objective function of irreversible single resonance energy selective electron heat engines

    International Nuclear Information System (INIS)

    Zhou, Junle; Chen, Lingen; Ding, Zemin; Sun, Fengrui

    2016-01-01

    Ecological performance of a single resonance ESE heat engine with heat leakage is conducted by applying finite time thermodynamics. By introducing Nielsen function and numerical calculations, expressions about power output, efficiency, entropy generation rate and ecological objective function are derived; relationships between ecological objective function and power output, between ecological objective function and efficiency as well as between power output and efficiency are demonstrated; influences of system parameters of heat leakage, boundary energy and resonance width on the optimal performances are investigated in detail; a specific range of boundary energy is given as a compromise to make ESE heat engine system work at optimal operation regions. Comparing performance characteristics with different optimization objective functions, the significance of selecting ecological objective function as the design objective is clarified specifically: when changing the design objective from maximum power output into maximum ecological objective function, the improvement of efficiency is 4.56%, while the power output drop is only 2.68%; when changing the design objective from maximum efficiency to maximum ecological objective function, the improvement of power output is 229.13%, and the efficiency drop is only 13.53%. - Highlights: • An irreversible single resonance energy selective electron heat engine is studied. • Heat leakage between two reservoirs is considered. • Power output, efficiency and ecological objective function are derived. • Optimal performance comparison for three objective functions is carried out.

  1. Logarithmic residues of analytic Banach algebra valued functions possessing a simply meromorphic inverse

    OpenAIRE

    Bart, Harm; Ehrhardt, T.; Silbermann, B.

    2001-01-01

    textabstractA logarithmic residue is a contour integral of a logarithmic derivative (left or right) of an analytic Banach algebra valued function. For functions possessing a meromorphic inverse with simple poles only, the logarithmic residues are identified as the sums of idempotents. With the help of this observation, the issue of left versus right logarithmic residues is investigated, both for connected and nonconnected underlying Cauchy domains. Examples are given to elucidate the subject ...

  2. The Einstein action for algebras of matrix valued functions - Toy models

    International Nuclear Information System (INIS)

    Hajac, P.M.

    1995-10-01

    Two toy models are considered within the framework of noncommutative differential geometry. In the first one, the Einstein action of the Levi-Civita connection is computed for the algebra of matrix valued functions on a torus. It is shown that, assuming some constraints on the metric, this action splits into a classical-like, a quantum-like and a mixed term. In the second model, an analogue of the Palatini method of variation is applied to obtain critical points of the Einstein action functional for M 4 (R). It is pointed out that a solution to the Palatini variational problem is not necessarily a Levi-Civita connection. In this model, no additional assumptions regarding metrics are made. (author). 14 refs

  3. High precision wavefront control in point spread function engineering for single emitter localization

    NARCIS (Netherlands)

    Siemons, M.E.; Thorsen, R.Ø; Smith, C.S.; Stallinga, S.

    2018-01-01

    Point spread function (PSF) engineering is used in single emitter localization to measure the emitter position in 3D and possibly other parameters such as the emission color or dipole orientation as well. Advanced PSF models such as spline fits to experimental PSFs or the vectorial PSF model can

  4. First-principles study of structural and work function properties for nitrogen-doped single-walled carbon nanotubes

    International Nuclear Information System (INIS)

    Shao, Xiji; Li, Detian; Cai, Jianqiu; Luo, Haijun; Dong, Changkun

    2016-01-01

    Graphical abstract: - Highlights: • Substitutional nitrogen atom doping in capped (5, 5) SWNT is investigated. • Serious defects appear from breaks of C−N bonds with N contents of above 23.3 at.%. • Work function drops after N doping and may reach 4.1 eV. - Abstract: The structural and electronic properties of the capped (5, 5) single-walled carbon nanotube (SWNT), including the structural stability, the work function, and the charge transfer performance, are investigated for the substitutional nitrogen atom doping under different concentrations by first-principles density functional theory. The geometrical structure keeps almost intact with single or two N atom doping, while C−N bonds may break up with serious defects for N concentrations of 23.3 at.% and above. The SWNT remains metallic and the work function drops after doping due to the upward shift of Fermi level, leading to the increase of the electrical conductivity. N doping enhances the oxygen reduction activity stronger than N adsorption because of higher charge transfers.

  5. Atrioventricular valve repair in patients with functional single-ventricle physiology: impact of ventricular and valve function and morphology on survival and reintervention.

    Science.gov (United States)

    Honjo, Osami; Atlin, Cori R; Mertens, Luc; Al-Radi, Osman O; Redington, Andrew N; Caldarone, Christopher A; Van Arsdell, Glen S

    2011-08-01

    This study was to determine whether atrioventricular valve repair modifies natural history of single-ventricle patients with atrioventricular valve insufficiency and to identify factors predicting survival and reintervention. Fifty-seven (13.5%) of 422 single-ventricle patients underwent atrioventricular valve repair. Valve morphology, regurgitation mechanism, and ventricular morphology and function were analyzed for effect on survival, transplant, and reintervention with multivariate logistic and Cox regression models. Comparative analysis used case-matched controls. Atrioventricular valve was tricuspid in 67% and common in 28%. Ventricular morphology was right in 83%. Regurgitation mechanisms were prolapse (n = 24, 46%), dysplasia (n = 18, 35%), annular dilatation (n = 8, 15%), and restriction or cleft (n = 2, 4%). Postrepair insufficiency was none or trivial in 14 (26%), mild in 33 (61%), and moderate in 7 (13%). Survival in repair group was lower than in matched controls (78.9% vs 92.7% at 1 year, 68.7% vs 90.6% at 3 years, P = .015). Patients with successful repair and normal ventricular function had equivalent survival to matched controls (P = .36). Independent predictors for death or transplant included increased indexed annular size (P = .05), increased cardiopulmonary bypass time (P = .04), and decreased postrepair ventricular function (P = .01). Ventricular dilation was a time-related factor for all events, including failed repair. Survival was lower in single-ventricle patients operated on for atrioventricular valve insufficiency than in case-matched controls. Patients with little postoperative residual regurgitation and preserved ventricular function had equivalent survival to controls. Lower grade ventricular function and ventricular dilation correlated with death and repair failure, suggesting that timing of intervention may affect outcome. Copyright © 2011 The American Association for Thoracic Surgery. Published by Mosby, Inc. All

  6. Attenuation of thermal neutrons by an imperfect single crystal

    Energy Technology Data Exchange (ETDEWEB)

    Naguib, K.; Adib, M. [National Research Centre, Cairo (Egypt). Reactor and Neutron Physics Dept.

    1996-06-14

    A semi-empirical formula is given which allows one to calculate the total thermal cross section of an imperfect single crystal as a function of crystal constants, temperature and neutron energy E, in the energy range between 3 meV and 10 eV. The formula also includes the contribution of the parasitic Bragg scattering to the total cross section that takes into account the crystal mosaic spread value and its orientation with respect to the neutron beam direction. A computer program (ISCANF) was developed to calculate the total attenuation of neutrons using the proposed formula. The ISCANF program was applied to investigate the neutron attenuation through a copper single crystal. The calculated values of the neutron transmission through the imperfect copper single crystal were fitted to the measured ones in the energy range 3-40 meV at different crystal orientations. The result of fitting shows that use of the computer program ISCANF allows one to predict the behaviour of the total cross section of an imperfect copper single crystal for the whole energy range. (author).

  7. Attenuation of thermal neutrons by an imperfect single crystal

    Science.gov (United States)

    Naguib, K.; Adib, M.

    1996-06-01

    A semi-empirical formula is given which allows one to calculate the total thermal cross section of an imperfect single crystal as a function of crystal constants, temperature and neutron energy E, in the energy range between 3 meV and 10 eV. The formula also includes the contribution of the parasitic Bragg scattering to the total cross section that takes into account the crystal mosaic spread value and its orientation with respect to the neutron beam direction. A computer program (ISCANF) was developed to calculate the total attenuation of neutrons using the proposed formula. The ISCANF program was applied to investigate the neutron attenuation through a copper single crystal. The calculated values of the neutron transmission through the imperfect copper single crystal were fitted to the measured ones in the energy range 3 - 40 meV at different crystal orientations. The result of fitting shows that use of the computer program ISCANF allows one to predict the behaviour of the total cross section of an imperfect copper single crystal for the whole energy range.

  8. Cognitive Functions, Personality Traits, and Social Values in Heavy Marihuana Smokers and Nonsmoker Controls

    Science.gov (United States)

    Weckowicz, Thaddeus E.; Janssen, Doug V.

    1973-01-01

    To determine the effect of chronic marihuana smoking on cognitive functions, personality traits, and social values, a group of heavy marihuana smokers was compared with a matched control group. (Author)

  9. Balkanizing the primate orbitofrontal cortex: distinct subregions for comparing and contrasting values.

    Science.gov (United States)

    Rudebeck, Peter H; Murray, Elisabeth A

    2011-12-01

    The primate orbitofrontal cortex (OFC) is often treated as a single entity, but architectonic and connectional neuroanatomy indicate that it has distinguishable parts. Nevertheless, few studies have attempted to dissociate the functions of its subregions. Here we review findings from recent neuropsychological and neurophysiological studies that do so. The lateral OFC seems to be important for learning, representing, and updating specific object-reward associations. The medial OFC seems to be important for value comparisons and choosing among objects on that basis. Rather than viewing this dissociation of function in terms of learning versus choosing, however, we suggest that it reflects the distinction between contrasts and comparisons: differences versus similarities. Making use of high-dimensional representations that arise from the convergence of several sensory modalities, the lateral OFC encodes contrasts among outcomes. The medial OFC reduces these contrasting representations of value to a single dimension, a common currency, in order to compare alternative choices. © 2011 New York Academy of Sciences.

  10. Parental Autonomy Granting and School Functioning among Chinese Adolescents: The Moderating Role of Adolescents’ Cultural Values

    Science.gov (United States)

    Wang, Cixin; Do, Kieu Anh; Bao, Leiping; Xia, Yan R.; Wu, Chaorong

    2017-01-01

    School adjustment and achievement are important indicators of adolescents’ well-being; however, few studies have examined the risk and protective factors predicting students’ school adjustment and achievement at the individual, familial, and cultural level. The present study examined the influences of individual and familial factors and cultural values on Chinese adolescents’ school functioning (e.g., school adjustment and grades). It also tested whether cultural values moderated the relationship between parenting and adolescents’ school functioning. Self-report data were collected from a stratified random sample of 2,864 adolescents (51.5% female, mean age = 15.52 years, grade 6th – 12th) from 55 classrooms, in 13 schools in Shanghai, China. Results showed that self-esteem (bse→adj = 0.05, SE = 0.01, p autonomy granting and adolescents’ grades (bindepxautom = 0.06, SE = 0.02, p cultural values may influence adolescents’ appraisal of parental autonomy granting, which then impacts their school functioning. PMID:29326622

  11. Assessment of respiratory symptoms and lung function values among the brick field workers of West Bengal, India.

    Science.gov (United States)

    Das, Banibrata

    2016-07-03

    Brick manufacturing process releases large amounts of silica dust into the work environment due to the use of silica-containing materials. The main aim of the study was to investigate the impairment of lung function and prevalence of respiratory symptoms among the different groups of brick field workers in comparison with control subjects. A total of 250 brick field workers and 130 unexposed control subjects were randomly selected in which demographic characteristics, respiratory symptoms, and lung function values were recorded. The result showed significantly lower p value (workers when compared with control group. The prevalence of respiratory symptoms was dyspnea (46.8%), phlegm (39.2%), and chest tightness (27.6%). Dust exposure in working environment affected the lung function values and increased the respiratory symptoms among the brick field workers.

  12. The role of three-gluon correlation functions in the single spin asymmetry

    Directory of Open Access Journals (Sweden)

    Beppu Hiroo

    2015-01-01

    Full Text Available We study the twist-3 three-gluon contribution to the single spin asymmetry in the light-hadron production in pp collision in the framework of the collinear factorization. We derive the corresponding cross section formula in the leading order with respect to the QCD coupling constant. We also present a numerical calculation of the asymmetry at the RHIC energy, using a model for the three-gluon correlation functions suggested by the asymmetry for the D-meson production at RHIC. We found that the asymmetries for the light-hadron and the jet productions are very useful to constrain the magnitude and form of the correlation functions. Since the three-gluon correlation functions shift the asymmetry for all kinds of hadrons in the same direction, it is unlikely that they become a main source of the asymmetry.

  13. Synergistic effect of non-covalent interaction in colloidal nematic liquid crystal doped with magnetic functionalized single-walled carbon nanotubes

    Science.gov (United States)

    Dalir, Nima; Javadian, Soheila

    2018-03-01

    Single-walled carbon nanotubes (SWCNTs), CNT@Fe3O4, and Fe3O4 nanocomposites were doped to eutectic uniaxial nematic liquid crystal (NLC's) (E5CN7) to improve physiochemical properties such as phase transition temperature, activation energy (Ea), dielectric anisotropy, and electro-optical properties. The thermal study of nematic phase shows a decrease in the nematic to isotropic phase transition temperature as CNT is doped. However, higher doping concentration of CNTs leads to the further increase in transition temperature. The anchoring effect or π-π interaction plays a key role in N-I phase transition. The functionalization of SWCNTs with Fe3O4 diminishes the CNT aggregation while the magnetic susceptibility is increased. The functionalized CNT doping to NLC's decrease significantly the phase transition temperature compared to doping of non-functionalized CNTs. Attractive interaction between guest and host molecules by magnetic and geometry effect increased the enthalpy and entropy of phase transition in the SWCNT@Fe3O4 sample compared to non-functionalized CNT doped system. Also, the Ea values are decreased as SWCNT@Fe3O4 is doped to pure E5CN7. The difference of N-I phase transition temperature was observed in Fe3O4 and CNT@Fe3O4 compared to SWCNT doped systems. Finally, dielectric anisotropy was increased in the doped system compared to pure NLC.

  14. The Einstein action for algebras of matrix valued functions - Toy models

    Energy Technology Data Exchange (ETDEWEB)

    Hajac, P M

    1995-10-01

    Two toy models are considered within the framework of noncommutative differential geometry. In the first one, the Einstein action of the Levi-Civita connection is computed for the algebra of matrix valued functions on a torus. It is shown that, assuming some constraints on the metric, this action splits into a classical-like, a quantum-like and a mixed term. In the second model, an analogue of the Palatini method of variation is applied to obtain critical points of the Einstein action functional for M{sub 4}(R). It is pointed out that a solution to the Palatini variational problem is not necessarily a Levi-Civita connection. In this model, no additional assumptions regarding metrics are made. (author). 14 refs.

  15. OPATs: Omnibus P-value association tests.

    Science.gov (United States)

    Chen, Chia-Wei; Yang, Hsin-Chou

    2017-07-10

    Combining statistical significances (P-values) from a set of single-locus association tests in genome-wide association studies is a proof-of-principle method for identifying disease-associated genomic segments, functional genes and biological pathways. We review P-value combinations for genome-wide association studies and introduce an integrated analysis tool, Omnibus P-value Association Tests (OPATs), which provides popular analysis methods of P-value combinations. The software OPATs programmed in R and R graphical user interface features a user-friendly interface. In addition to analysis modules for data quality control and single-locus association tests, OPATs provides three types of set-based association test: window-, gene- and biopathway-based association tests. P-value combinations with or without threshold and rank truncation are provided. The significance of a set-based association test is evaluated by using resampling procedures. Performance of the set-based association tests in OPATs has been evaluated by simulation studies and real data analyses. These set-based association tests help boost the statistical power, alleviate the multiple-testing problem, reduce the impact of genetic heterogeneity, increase the replication efficiency of association tests and facilitate the interpretation of association signals by streamlining the testing procedures and integrating the genetic effects of multiple variants in genomic regions of biological relevance. In summary, P-value combinations facilitate the identification of marker sets associated with disease susceptibility and uncover missing heritability in association studies, thereby establishing a foundation for the genetic dissection of complex diseases and traits. OPATs provides an easy-to-use and statistically powerful analysis tool for P-value combinations. OPATs, examples, and user guide can be downloaded from http://www.stat.sinica.edu.tw/hsinchou/genetics/association/OPATs.htm. © The Author 2017

  16. Functionalization of single-walled carbon nanotubes regulates their effect on hemostasis

    International Nuclear Information System (INIS)

    Sokolov, A V; Aseychev, A V; Kostevich, V A; Gusev, A A; Gusev, S A; Vlasova, I I

    2011-01-01

    Applications of single-walled carbon nanotubes (SWNTs) in medical field imply the use of drug-coupled carbon nanotubes as well as carbon nanotubes functionalized with different chemical groups that change nanotube surface properties and interactions between nanotubes and cells. Covalent attachment of polyethylene glycol (PEG) to carboxylated single-walled carbon nanotubes (c-SWNT) is known to prevent the nanotubes from interaction with macrophages. Here we characterized nanotube's ability to stimulate coagulation processes in platelet-poor plasma (PPP), and evaluated the effect of SWNTs on platelet aggregation in platelet-rich plasma (PRP). Our study showed that PEG-SWNT did not affect the rate of clotting in PPP, while c-SWNT shortened the clot formation time five times compared to the control PPP. Since c-SWNT failed to accelerate coagulation in plasma lacking coagulation factor XI, it may be suggested that c-SWNT affects the contact activation pathway. In PRP, platelets responded to both SWNT types with irreversible aggregation, as evidenced by changes in the aggregate mean radius. However, the rate of aggregation induced by c-SWNT was two times higher than it was with PEG-SWNT. Cytological analysis also showed that c-SWNT was two times more efficient when compared to PEG-SWNT in aggregating platelets in PRP. Taken together, our results show that functionalization of nanoparticles can diminish their negative influence on blood cells. As seen from our data, modification of c-SWNT with PEG, when only a one percent of carbon atoms is bound to polymer (70 wt %), decreased the nanotube-induced coagulation in PRP and repelled the accelerating effect on the coagulation in PPP. Thus, when functionalized SWNTs are used for administration into bloodstream of laboratory animals, their possible pro-coagulant and pro-aggregating properties must be taken into account.

  17. Functionalization of single-walled carbon nanotubes regulates their effect on hemostasis

    Energy Technology Data Exchange (ETDEWEB)

    Sokolov, A V; Aseychev, A V; Kostevich, V A; Gusev, A A; Gusev, S A; Vlasova, I I, E-mail: irina.vlasova@yahoo.com [Research Institute for Physico-Chemical Medicine, FMBA, M. Pirogovskaya Str. 1a, Moscow (Russian Federation)

    2011-04-01

    Applications of single-walled carbon nanotubes (SWNTs) in medical field imply the use of drug-coupled carbon nanotubes as well as carbon nanotubes functionalized with different chemical groups that change nanotube surface properties and interactions between nanotubes and cells. Covalent attachment of polyethylene glycol (PEG) to carboxylated single-walled carbon nanotubes (c-SWNT) is known to prevent the nanotubes from interaction with macrophages. Here we characterized nanotube's ability to stimulate coagulation processes in platelet-poor plasma (PPP), and evaluated the effect of SWNTs on platelet aggregation in platelet-rich plasma (PRP). Our study showed that PEG-SWNT did not affect the rate of clotting in PPP, while c-SWNT shortened the clot formation time five times compared to the control PPP. Since c-SWNT failed to accelerate coagulation in plasma lacking coagulation factor XI, it may be suggested that c-SWNT affects the contact activation pathway. In PRP, platelets responded to both SWNT types with irreversible aggregation, as evidenced by changes in the aggregate mean radius. However, the rate of aggregation induced by c-SWNT was two times higher than it was with PEG-SWNT. Cytological analysis also showed that c-SWNT was two times more efficient when compared to PEG-SWNT in aggregating platelets in PRP. Taken together, our results show that functionalization of nanoparticles can diminish their negative influence on blood cells. As seen from our data, modification of c-SWNT with PEG, when only a one percent of carbon atoms is bound to polymer (70 wt %), decreased the nanotube-induced coagulation in PRP and repelled the accelerating effect on the coagulation in PPP. Thus, when functionalized SWNTs are used for administration into bloodstream of laboratory animals, their possible pro-coagulant and pro-aggregating properties must be taken into account.

  18. Single-injection method for evaluation of renal function with 14C-inulin and 3H-tetraethylammonium bromide in dogs and cats

    International Nuclear Information System (INIS)

    Fettman, M.J.; Allen, T.A.; Wilke, W.L.; Radin, M.J.; Eubank, M.C.

    1985-01-01

    A double-isotope single-injection method without urine collection for the estimation of glomerular filtration rate (GFR) and effective renal plasma flow (ERPF) in dogs and cats was evaluated. The GFR was determined, using 14 C-inulin and ERPF was determined, using [ 3 H]tetraethylammonium bromide. Using a modified single exponential, 1-compartment mathematical model, the renal clearance of these solutes was estimated with a plasma radioactivity disappearance curve constructed from samples collected over a 150-minute time period. In 25 dogs, GFR, ERPF, and filtration fraction were 3.55 +/- 0.14 ml/kg/min, 10.51 +/- 0.72 ml/kg/min, and 0.34 +/- 0.02, respectively. In 25 cats, GFR, ERPF, and filtration fraction were 3.24 +/- 0.14 ml/kg/min, 8.14 +/- 0.53 ml/kg/min, and 0.39 +/- 0.02, respectively. This time-efficient and reliable method, using beta-emitting isotopes, yielded renal functional values well within the normal ranges reported by a variety of other isotopic and nonisotopic procedures. The advantages of the present procedure over previous double-isotope single-injection methods include the use of less costly, lower energy-using, and less penetrating beta emittors, as well as a shortened blood sampling schedule

  19. Considering dominance in reduced single-step genomic evaluations.

    Science.gov (United States)

    Ertl, J; Edel, C; Pimentel, E C G; Emmerling, R; Götz, K-U

    2018-06-01

    Single-step models including dominance can be an enormous computational task and can even be prohibitive for practical application. In this study, we try to answer the question whether a reduced single-step model is able to estimate breeding values of bulls and breeding values, dominance deviations and total genetic values of cows with acceptable quality. Genetic values and phenotypes were simulated (500 repetitions) for a small Fleckvieh pedigree consisting of 371 bulls (180 thereof genotyped) and 553 cows (40 thereof genotyped). This pedigree was virtually extended for 2,407 non-genotyped daughters. Genetic values were estimated with the single-step model and with different reduced single-step models. Including more relatives of genotyped cows in the reduced single-step model resulted in a better agreement of results with the single-step model. Accuracies of genetic values were largest with single-step and smallest with reduced single-step when only the cows genotyped were modelled. The results indicate that a reduced single-step model is suitable to estimate breeding values of bulls and breeding values, dominance deviations and total genetic values of cows with acceptable quality. © 2018 Blackwell Verlag GmbH.

  20. Reference change values and power functions

    DEFF Research Database (Denmark)

    Iglesias Canadell, Natàlia; Hyltoft Petersen, Per; Jensen, Esther

    2004-01-01

    Repeated samplings and measurements in the monitoring of patients to look for changes are common clinical problems. The "reference change value", calculated as zp x [2 x (CVI2 + CVA2)](1/2), where zp is the z-statistic and CVI and CVA are within-subject and analytical coefficients of variation......, respectively, has been used to detect whether a measured difference between measurements is statistically significant. However, a reference change value only detects the probability of false-positives (type I error), and for this reason, a model to calculate the risk of missing significant changes in serial...... difference is the same as the calculated reference change value, then it will be detected in only 50% of situations....

  1. STRUCTURAL AND FUNCTIONAL-ANALYSIS OF THE SINGLE-STRAND ORIGIN OF REPLICATION FROM THE LACTOCOCCAL PLASMID PWVO1

    NARCIS (Netherlands)

    SEEGERS, JFML; ZHAO, AC; MEIJER, WJJ; KHAN, SA; VENEMA, G; BRON, S

    1995-01-01

    The single-strand origin (SSO) of the rolling-circle (RC), broad-host-range lactococcal plasmid pWVO1 was functionally characterized. The activity of this SSO in the conversion of single-stranded DNA to double-stranded DNA was tested both in vivo and in vitro. In addition, the effect of this SSO on

  2. Influence of uranium dioxide nonstoichiometric oxygen on the work function of Mo(110) single crystal

    International Nuclear Information System (INIS)

    Bekmukhabetov, E.S.; Dzhajmurzin, A.A.; Imanbekov, Zh.Zh.

    1985-01-01

    The influence of the uranium dioxide nonstoichiometric oxygen on the work function of a Mo(110) single crystal has been studied. When the surface diffusion of oxygen on the tested surface takes place, the work function is shown to decrease and, subsequently, to increase until it becomes stable. The dependence of the work function on the temperature of the specimen in the range of 1600-1900 K with a minimum at 1730 K has been found. The minimum is attributed to the dipole layer formation

  3. Multi-channel distributed coordinated function over single radio in wireless sensor networks.

    Science.gov (United States)

    Campbell, Carlene E-A; Loo, Kok-Keong Jonathan; Gemikonakli, Orhan; Khan, Shafiullah; Singh, Dhananjay

    2011-01-01

    Multi-channel assignments are becoming the solution of choice to improve performance in single radio for wireless networks. Multi-channel allows wireless networks to assign different channels to different nodes in real-time transmission. In this paper, we propose a new approach, Multi-channel Distributed Coordinated Function (MC-DCF) which takes advantage of multi-channel assignment. The backoff algorithm of the IEEE 802.11 distributed coordination function (DCF) was modified to invoke channel switching, based on threshold criteria in order to improve the overall throughput for wireless sensor networks (WSNs) over 802.11 networks. We presented simulation experiments in order to investigate the characteristics of multi-channel communication in wireless sensor networks using an NS2 platform. Nodes only use a single radio and perform channel switching only after specified threshold is reached. Single radio can only work on one channel at any given time. All nodes initiate constant bit rate streams towards the receiving nodes. In this work, we studied the impact of non-overlapping channels in the 2.4 frequency band on: constant bit rate (CBR) streams, node density, source nodes sending data directly to sink and signal strength by varying distances between the sensor nodes and operating frequencies of the radios with different data rates. We showed that multi-channel enhancement using our proposed algorithm provides significant improvement in terms of throughput, packet delivery ratio and delay. This technique can be considered for WSNs future use in 802.11 networks especially when the IEEE 802.11n becomes popular thereby may prevent the 802.15.4 network from operating effectively in the 2.4 GHz frequency band.

  4. DW-MRI of liver lesions: Can a single ADC-value represent the entire lesion?

    International Nuclear Information System (INIS)

    Schmid-Tannwald, C.; Dahi, F.; Jiang, Y.; Ivancevic, M.K.; Rist, C.; Sethi, I.; Oommen, J.; Oto, A.

    2014-01-01

    Aim: To evaluate whether focal liver lesions (FLLs) exhibit a homogeneous appearance on apparent diffusion coefficient (ADC) maps and whether there is inter-section variation in the calculated ADC values of FLLs (inter-section range). Materials and methods: Eighty-eight patients with 128 FLLs (70 benign, 58 malignant) who underwent abdominal magnetic resonance imaging (MRI) including diffusion-weighted (DW)-MRI were included. Two observers evaluated variation of signal intensity of each FLL within each ADC map image (intra-section) and among different ADC map images through the lesion (inter-section). ADC values of each FLL and neighbouring liver parenchyma were measured on all sections. The inter-section range of FLLs was compared with the neighbouring liver parenchyma. Results: Intra-section inhomogeneity was noted in 39.8% (97/244 sections) and 38.9% (95/244) of benign lesions, and 61% (114/187 sections) and 61.5% (115/187) of malignant lesions, by observer 1 and observer 2, respectively. Inter-section inhomogeneity was noted in 25.7% (18/70) and 27.1% (19/70) of benign lesions, and 51.7% (30/58) and 50% (29/58) of malignant lesions, by observer 1 and observer 2, respectively. The inter-section range for both benign (0.28 × 10 −3  mm²/s) and malignant (0.25 × 10 −3  mm²/s) FLLs were significantly greater than that of liver parenchyma surrounding benign (0.16 × 10 −3  mm²/s, p < 0.001) and malignant (0.14 × 10 −3  mm²/s, p = 0.01) FLLs. Conclusion: Due to intra-/inter-section variations in ADC values of benign and malignant FLLs, a single ADC value may not reliably represent the entire lesion

  5. Likelihood functions for the analysis of single-molecule binned photon sequences

    Energy Technology Data Exchange (ETDEWEB)

    Gopich, Irina V., E-mail: irinag@niddk.nih.gov [Laboratory of Chemical Physics, National Institute of Diabetes and Digestive and Kidney Diseases, National Institutes of Health, Bethesda, MD 20892 (United States)

    2012-03-02

    Graphical abstract: Folding of a protein with attached fluorescent dyes, the underlying conformational trajectory of interest, and the observed binned photon trajectory. Highlights: Black-Right-Pointing-Pointer A sequence of photon counts can be analyzed using a likelihood function. Black-Right-Pointing-Pointer The exact likelihood function for a two-state kinetic model is provided. Black-Right-Pointing-Pointer Several approximations are considered for an arbitrary kinetic model. Black-Right-Pointing-Pointer Improved likelihood functions are obtained to treat sequences of FRET efficiencies. - Abstract: We consider the analysis of a class of experiments in which the number of photons in consecutive time intervals is recorded. Sequence of photon counts or, alternatively, of FRET efficiencies can be studied using likelihood-based methods. For a kinetic model of the conformational dynamics and state-dependent Poisson photon statistics, the formalism to calculate the exact likelihood that this model describes such sequences of photons or FRET efficiencies is developed. Explicit analytic expressions for the likelihood function for a two-state kinetic model are provided. The important special case when conformational dynamics are so slow that at most a single transition occurs in a time bin is considered. By making a series of approximations, we eventually recover the likelihood function used in hidden Markov models. In this way, not only is insight gained into the range of validity of this procedure, but also an improved likelihood function can be obtained.

  6. Graft function assessment in mouse models of single- and dual- kidney transplantation.

    Science.gov (United States)

    Wang, Lei; Wang, Ximing; Jiang, Shan; Wei, Jin; Buggs, Jacentha; Fu, Liying; Zhang, Jie; Liu, Ruisheng

    2018-05-23

    Animal models of kidney transplantation (KTX) are widely used in studying immune response of hosts to implanted grafts. Additionally, KTX can be used in generating kidney-specific knockout animal models by transplantation of kidneys from donors with global knockout of a gene to wild type recipients or vise verse. Dual kidney transplantation (DKT) provides a more physiological environment for recipients than single kidney transplantation (SKT). However, DKT in mice is rare due to technical challenges. In this study, we successfully performed DKT in mice and compared the hemodynamic response and graft function with SKT. The surgical time, complications and survival rate of DKT were not significantly different from SKT, where survival rates were above 85%. Mice with DKT showed less injury and quicker recovery with lower plasma creatinine (Pcr) and higher GFR than SKT mice (Pcr = 0.34 and 0.17 mg/dl in DKT vs. 0.50 and 0.36 mg/dl in SKT at 1 and 3 days, respectively; GFR = 215 and 131 µl/min for DKT and SKT, respectively). In addition, the DKT exhibited better renal functional reserve and long-term outcome of renal graft function than SKT based on the response to acute volume expansion. In conclusion, we have successfully generated a mouse DKT model. The hemodynamic responses of DKT better mimic physiological situations with less kidney injury and better recovery than SKT because of reduced confounding factors such as single nephron hyperfiltration. We anticipate DKT in mice will provide an additional tool for evaluation of renal significance in physiology and disease.

  7. Functional adaptation to loading of a single bone is neuronally regulated and involves multiple bones.

    Science.gov (United States)

    Sample, Susannah J; Behan, Mary; Smith, Lesley; Oldenhoff, William E; Markel, Mark D; Kalscheur, Vicki L; Hao, Zhengling; Miletic, Vjekoslav; Muir, Peter

    2008-09-01

    Regulation of load-induced bone formation is considered a local phenomenon controlled by osteocytes, although it has also been hypothesized that functional adaptation may be neuronally regulated. The aim of this study was to examine bone formation in multiple bones, in response to loading of a single bone, and to determine whether adaptation may be neuronally regulated. Load-induced responses in the left and right ulnas and humeri were determined after loading of the right ulna in male Sprague-Dawley rats (69 +/- 16 days of age). After a single period of loading at -760-, -2000-, or -3750-microepsilon initial peak strain, rats were given calcein to label new bone formation. Bone formation and bone neuropeptide concentrations were determined at 10 days. In one group, temporary neuronal blocking was achieved by perineural anesthesia of the brachial plexus with bupivicaine during loading. We found right ulna loading induces adaptive responses in other bones in both thoracic limbs compared with Sham controls and that neuronal blocking during loading abrogated bone formation in the loaded ulna and other thoracic limb bones. Skeletal adaptation was more evident in distal long bones compared with proximal long bones. We also found that the single period of loading modulated bone neuropeptide concentrations persistently for 10 days. We conclude that functional adaptation to loading of a single bone in young rapidly growing rats is neuronally regulated and involves multiple bones. Persistent changes in bone neuropeptide concentrations after a single loading period suggest that plasticity exists in the innervation of bone.

  8. Independent prognostic value of left ventricular mass, diastolic function, and fasting plasma glucose

    DEFF Research Database (Denmark)

    Pareek, Manan; Nielsen, Mette Lundgren; Leósdóttir, Margrét

    2016-01-01

    OBJECTIVE: To explore the independent prognostic value of left ventricular (LV) mass, diastolic function, and fasting plasma glucose (FPG) for the prediction of incident cardiac events in a random population sample. DESIGN AND METHOD: 415 women and 999 men aged 56-79 years, included between 2002...

  9. Oriented growing and anisotropy of emission properties of lanthanum hexaboride single crystals

    International Nuclear Information System (INIS)

    Lazorenko, V.I.; Lotsko, D.V.; Platonov, V.F.; Kovalev, A.V.; Galasun, A.P.; Matvienko, A.A.; Klinkov, A.E.

    1987-01-01

    Single crystals of lanthanum hexaboride with preset crystallographic orientation are grown by the method of crucible-free zone melting. It is shown that oriented growing of single crystals of the given compound is possible only when using seed crystals of the required orientation because no predominant orientation of the LaB 6 growth is found in case of spontaneous crystallization. Orientation of spontaneously growing LaB 6 crystals does not depend on their growth rate, degree of the melt diffusion annealing, purity of the inital powder. Anisotropy of the electronic work function for single crystal lanthanum hexaboride is confirmed. Its value grows as (100)<(110)<(111). Conditions of the preliminary thermovacuum purification of the surface are shown to affect the measured work function

  10. Onsite-effects of dual-hemisphere versus conventional single-hemisphere transcranial direct current stimulation: A functional MRI study.

    Science.gov (United States)

    Kwon, Yong Hyun; Jang, Sung Ho

    2012-08-25

    We performed functional MRI examinations in six right-handed healthy subjects. During functional MRI scanning, transcranial direct current stimulation was delivered with the anode over the right primary sensorimotor cortex and the cathode over the left primary sensorimotor cortex using dual-hemispheric transcranial direct current stimulation. This was compared to a cathode over the left supraorbital area using conventional single-hemispheric transcranial direct current stimulation. Voxel counts and blood oxygenation level-dependent signal intensities in the right primary sensorimotor cortex regions were estimated and compared between the two transcranial direct current stimulation conditions. Our results showed that dual-hemispheric transcranial direct current stimulation induced greater cortical activities than single-hemispheric transcranial direct current stimulation. These findings suggest that dual-hemispheric transcranial direct current stimulation may provide more effective cortical stimulation than single-hemispheric transcranial direct current stimulation.

  11. Detection of single-copy functional genes in prokaryotic cells by two-pass TSA-FISH with polynucleotide probes.

    Science.gov (United States)

    Kawakami, Shuji; Hasegawa, Takuya; Imachi, Hiroyuki; Yamaguchi, Takashi; Harada, Hideki; Ohashi, Akiyoshi; Kubota, Kengo

    2012-02-01

    In situ detection of functional genes with single-cell resolution is currently of interest to microbiologists. Here, we developed a two-pass tyramide signal amplification (TSA)-fluorescence in situ hybridization (FISH) protocol with PCR-derived polynucleotide probes for the detection of single-copy genes in prokaryotic cells. The mcrA gene and the apsA gene in methanogens and sulfate-reducing bacteria, respectively, were targeted. The protocol showed bright fluorescence with a good signal-to-noise ratio and achieved a high efficiency of detection (>98%). The discrimination threshold was approximately 82-89% sequence identity. Microorganisms possessing the mcrA or apsA gene in anaerobic sludge samples were successfully detected by two-pass TSA-FISH with polynucleotide probes. The developed protocol is useful for identifying single microbial cells based on functional gene sequences. Copyright © 2011 Elsevier B.V. All rights reserved.

  12. Enhancing High Value Care in Gastroenterology Practice.

    Science.gov (United States)

    Camilleri, Michael; Katzka, David A

    2016-10-01

    The objective of this review is to identify common areas in gastroenterology practice where studies performed provide an opportunity for enhancing value or lowering costs. We provide examples of topics in gastroenterology where clinicians could enhance value by either using less invasive testing, choosing a single best test, or by using patient symptoms to guide additional testing. The topics selected for review are selected in esophageal, pancreatic, and colorectal cancer; functional gastrointestinal diseases (irritable bowel syndrome, bacterial overgrowth, constipation); immune-mediated gastrointestinal diseases; and pancreaticobiliary pathology. We propose guidance to alter practice based on current evidence. These studies support the need to review current practice and to continue performing research to further validate the proposed guidance to enhance value of care in gastroenterology and hepatology. Copyright © 2016 AGA Institute. Published by Elsevier Inc. All rights reserved.

  13. Functions and requirements for Hanford single-shell tank leakage detection and monitoring

    International Nuclear Information System (INIS)

    Cruse, J.M.; Ohl, P.C.

    1995-01-01

    This document provides the initial functions and requirements for leakage detection and monitoring applicable to past and potential future leakage from the Hanford Site's 149 single-shell high-level waste tanks. This mission is a part of the overall mission of the Westinghouse Hanford Company Tank Waste Remediation System division to remediate the tank waste in a safe and acceptable manner. Systems engineering principles are being applied to this effort. This document reflects the an initial step in the systems engineering approach to decompose the mission into primary functions and requirements. The document is considered approximately 30% complete relative to the effort required to produce a final version that can be used to support demonstration and/or procurement of technologies. The functions and requirements in this document apply to detection and monitoring of below ground leaks from SST containment boundaries and the resulting soil contamination. Leakage detection and monitoring is invoked in the TWRS Program in three fourth level functions: (1) Store Waste, (2) Retrieve Waste, and (3) Disposition Excess Facilities (as identified in DOE/RL-92-60 Rev. 1, Tank Waste Remediation System Functions and Requirements)

  14. Effects of ageing on single muscle fibre contractile function following short-term immobilisation

    DEFF Research Database (Denmark)

    Hvid, Lars G; Ortenblad, Niels; Aagaard, Per

    2011-01-01

    Very little attention has been given to the combined effects of healthy ageing and short-term disuse on the contractile function of human single muscle fibres. Therefore, the present study investigated the effects of 2 weeks of lower limb cast immobilisation (i.e. disuse) on selected contractile...... IIa: young 18% and old 25%; P selective decrease in Ca(2+) sensitivity in MHC IIa fibres of young (P ....05), respectively. In conclusion, 2 weeks of lower limb immobilisation caused greater impairments in single muscle fibre force and specific force in MHC IIa than MHC I fibres independently of age. In contrast, immobilisation-induced changes in Ca(2+) sensitivity that were dependent on age and MHC isoform....

  15. Monitoring the functionalization of single-walled carbon nanotubes with chitosan and folic acid by two-dimensional diffusion-ordered nmr spectroscopy

    DEFF Research Database (Denmark)

    Castillo, John J.; Torres, Mary H.; Molina, Daniel R.

    2012-01-01

    A conjugate between single-walled carbon nanotubes, chitosan and folic acid has been prepared. It was characterized by diffusion ordered two-dimensional hydrogen-1 nuclear magnetic resonance and hydrogen-1 nuclear magnetic resonance spectroscopy which revealed the presence of a conjugate that was......A conjugate between single-walled carbon nanotubes, chitosan and folic acid has been prepared. It was characterized by diffusion ordered two-dimensional hydrogen-1 nuclear magnetic resonance and hydrogen-1 nuclear magnetic resonance spectroscopy which revealed the presence of a conjugate...... that was generated by the linkage between the carboxyl moiety of the folic acid and the amino group of the chitosan, which in turn was non-covalently bound to the single-walled carbon nanotubes. The obtained diffusion coefficient values demonstrated that free folic acid diffused more rapidly than the folic acid...... conjugated to single-walled carbon nanotubes-chitosan. The values of the proton signal of hydrogen-1 nuclear magnetic resonance spectroscopy and two-dimensional hydrogen-1 nuclear magnetic resonance spectroscopy further confirmed that the folic acid was conjugated to the chitosan, wrapping the single...

  16. Strategic Functionalization of Single Walled Carbon Nanotubes to Manipulate Their Electronic and Optical Properties

    Science.gov (United States)

    Gifford, Brendan Joel

    Single-walled carbon nanotubes (SWCNTs) are unique materials that exhibit chirality-specific properties due to their one-dimensional confinement. As a result, they are explored for a wide range of applications including single-photon sources in communications devices. Despite progress in this area, SWCNTs still suffer from a relatively narrow range of energies of emission features that fall short of the 1500 nm desired for long-distance lossless data transfer. One approach that is frequently used to resolve this involves chemical functionalization with aryl groups. However, this approach is met with a number of fundamental issues. First, chirality-specific SWCNTs must be acquired for subsequent functionalization. Synthesis of such samples has thus far eluded experimental efforts. As such, post-synthetic non-covalent functionalization is required to break bundles and create disperse SWCNTs that can undergo further separation, processing, and functionalization. Second, a number of low-energy emission features are introduced upon functionalization across a 200 nm range. The origin of such diverse emission features remains unknown. The research presented here focuses on computationally addressing these issues. A series of polyfluorene polymers possessing sidechains of varying length are explored using molecular mechanics to determine the impact of alkyl sidechains on SWCNT-conjugated polymer interaction strength and morphology. Additionally, density functional theory (DFT) and linear-response time-dependent DFT (TDDFT) are used to explore the effect of functionalization on emission features. A prerequisite to these calculations involves constructing finite-length SWCNT systems with similar electronic structure to their infinite counterparts: a methodological approach for the formation of such systems is presented. The optical features for aryl-functionalized SWCNTs are then explored. It is shown that the predominant effect on the energies of emission features involves

  17. Awareness of single and multiple emotions in high-functioning childeren with autism

    OpenAIRE

    Rieffe, C.J.; Meerum Terwogt, M.; Kotronopoulo, K.

    2007-01-01

    This study examined emotional awareness in children with autism. Twenty-two high functioning children with autism (mean age 10 years and 2 months) and 22 typically developing children, matched for age and gender, were presented with the four basic emotions (happiness, anger, sadness and fear) in single and multiple emotion tasks. Findings suggest that children with autism have difficulties identifying their own emotions and less developed emotion concepts (which causes an impaired capacity to...

  18. Determination and shaping of the ion-velocity distribution function in a single-ended Q machine

    DEFF Research Database (Denmark)

    Andersen, S.A.; Jensen, Vagn Orla; Michelsen, Poul

    1971-01-01

    An electrostatic energy analyzer with a resolution better than 0.03 eV was constructed. This analyzer was used to determine the ion-velocity distribution function at different densities and plate temperatures in a single-ended Q machine. In all regions good agreement with theoretical predictions...... based on simple, physical pictures is obtained. It is shown that within certain limits the velocity distribution function can be shaped; double-humped distribution functions have been obtained. The technique used here is suggested as an accurate method for determination of plasma densities within 10...

  19. From tomography to full-waveform inversion with a single objective function

    KAUST Repository

    Alkhalifah, Tariq Ali

    2014-02-17

    In full-waveform inversion (FWI), a gradient-based update of the velocity model requires an initial velocity that produces synthetic data that are within a half-cycle, everywhere, from the field data. Such initial velocity models are usually extracted from migration velocity analysis or traveltime tomography, among other means, and are not guaranteed to adhere to the FWI requirements for an initial velocity model. As such, we evaluated an objective function based on the misfit in the instantaneous traveltime between the observed and modeled data. This phase-based attribute of the wavefield, along with its phase unwrapping characteristics, provided a frequency-dependent traveltime function that was easy to use and quantify, especially compared to conventional phase representation. With a strong Laplace damping of the modeled, potentially low-frequency, data along the time axis, this attribute admitted a first-arrival traveltime that could be compared with picked ones from the observed data, such as in wave equation tomography (WET). As we relax the damping on the synthetic and observed data, the objective function measures the misfit in the phase, however unwrapped. It, thus, provided a single objective function for a natural transition from WET to FWI. A Marmousi example demonstrated the effectiveness of the approach.

  20. Electron-vibron coupling effects on electron transport via a single-molecule magnet

    NARCIS (Netherlands)

    McCaskey, A.; Yamamoto, Y.; Warnock, M.; Burzuri, E.; Van der Zant, H.S.J.; Park, K.

    2015-01-01

    We investigate how the electron-vibron coupling influences electron transport via an anisotropic magnetic molecule, such as a single-molecule magnet (SMM) Fe4, by using a model Hamiltonian with parameter values obtained from density-functional theory (DFT). The magnetic anisotropy parameters,

  1. Conference on Commutative rings, integer-valued polynomials and polynomial functions

    CERN Document Server

    Frisch, Sophie; Glaz, Sarah; Commutative Algebra : Recent Advances in Commutative Rings, Integer-Valued Polynomials, and Polynomial Functions

    2014-01-01

    This volume presents a multi-dimensional collection of articles highlighting recent developments in commutative algebra. It also includes an extensive bibliography and lists a substantial number of open problems that point to future directions of research in the represented subfields. The contributions cover areas in commutative algebra that have flourished in the last few decades and are not yet well represented in book form. Highlighted topics and research methods include Noetherian and non- Noetherian ring theory as well as integer-valued polynomials and functions. Specific topics include: ·    Homological dimensions of Prüfer-like rings ·    Quasi complete rings ·    Total graphs of rings ·    Properties of prime ideals over various rings ·    Bases for integer-valued polynomials ·    Boolean subrings ·    The portable property of domains ·    Probabilistic topics in Intn(D) ·    Closure operations in Zariski-Riemann spaces of valuation domains ·    Stability of do...

  2. Calculating p-values and their significances with the Energy Test for large datasets

    Science.gov (United States)

    Barter, W.; Burr, C.; Parkes, C.

    2018-04-01

    The energy test method is a multi-dimensional test of whether two samples are consistent with arising from the same underlying population, through the calculation of a single test statistic (called the T-value). The method has recently been used in particle physics to search for samples that differ due to CP violation. The generalised extreme value function has previously been used to describe the distribution of T-values under the null hypothesis that the two samples are drawn from the same underlying population. We show that, in a simple test case, the distribution is not sufficiently well described by the generalised extreme value function. We present a new method, where the distribution of T-values under the null hypothesis when comparing two large samples can be found by scaling the distribution found when comparing small samples drawn from the same population. This method can then be used to quickly calculate the p-values associated with the results of the test.

  3. Prognostic Value of Normal Perfusion but Impaired Left Ventricular Function in the Diabetic Heart on Quantitative Gated Myocardial Perfusion SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Hwanjeong; Choi, Sehun; Han, Yeonhee [Research Institute of Chonbuk National Univ. Medical School and Hospitial, Jeonju (Korea, Republic of); Lee, Dong Soo; Lee, Hoyoung; Chung, Junekey [Seoul National Univ., Seoul (Korea, Republic of)

    2013-09-15

    This study aimed at identifying the predictive parameters on quantitative gated myocardial perfusion single-photon emission computed tomography (QG-SPECT) in diabetic patients with normal perfusion but impaired function. Methods Among the 533 consecutive diabetic patients, 379 patients with normal perfusion on rest Tl-201/dipyridamole-stress Tc-{sup 99m} sestamibi Gated SPECT were enrolled. Patients were grouped into those with normal post-stress left ventricular function (Group I) and those with impaired function (EF <50 or impaired regional wall motion, Group II). We investigated cardiac events and cause of death by chart review and telephone interview. Survival analysis and Cox proportional hazard model analysis were performed. Between the Group I and II, cardiac events as well as chest pain symptoms, smoking, diabetic complications were significantly different (P<0.05). On survival analysis, event free survival rate in Group II was significantly lower than in Group I (P=0.016). In univariate Cox proportional hazard analysis on overall cardiac event, Group (II over I), diabetic nephropathy, summed motion score (SMS), summed systolic thickening score (STS), numbers of abnormal segmental wall motion and systolic thickening predicted more cardiac events (P<0.05). Multivariate analysis showed that STS was the only independent predictor cardiac event. The functional parameter, especially summed systolic thickening score on QG-SPECT had prognostic values, despite normal perfusion, in predicting cardiac events in diabetic patients, and QG-SPECT provides clinically useful risk stratification in diabetic patients with normal perfusion.

  4. An analysis of the accuracy of an initial value representation surface hopping wave function in the interaction and asymptotic regions

    International Nuclear Information System (INIS)

    Sergeev, Alexey; Herman, Michael F.

    2006-01-01

    The behavior of an initial value representation surface hopping wave function is examined. Since this method is an initial value representation for the semiclassical solution of the time independent Schroedinger equation for nonadiabatic problems, it has computational advantages over the primitive surface hopping wave function. The primitive wave function has been shown to provide transition probabilities that accurately compare with quantum results for model problems. The analysis presented in this work shows that the multistate initial value representation surface hopping wave function should approach the primitive result in asymptotic regions and provide transition probabilities with the same level of accuracy for scattering problems as the primitive method

  5. ERP in chronic pancreatitis - ductal morphology, relation to exocrine function and pain - clinical value

    International Nuclear Information System (INIS)

    Norup Lauridsen, K.; Raahede, J.; Kruse, A.; Thommesen, P.; Aarhus Univ.

    1985-01-01

    ERP was analyzed in 87 patients with chronic pancreatitis with special reference to its clinical value in management of pain, the dominating symptom in uncomplicated chronic pancreatitis. A significant correlation was found between ductal changes due to pancreatitis and decrease in pancreatic function. However, no association was found between severe pancreatic pain and pancreatic function or pancreatic morphology. The significance of ERP in management of patients with persistent severe pancreatic pain is discussed. (orig.) [de

  6. Maple (Computer Algebra System) in Teaching Pre-Calculus: Example of Absolute Value Function

    Science.gov (United States)

    Tuluk, Güler

    2014-01-01

    Modules in Computer Algebra Systems (CAS) make Mathematics interesting and easy to understand. The present study focused on the implementation of the algebraic, tabular (numerical), and graphical approaches used for the construction of the concept of absolute value function in teaching mathematical content knowledge along with Maple 9. The study…

  7. Spectrum-to-dose conversion operator value function of a Ge(Li) in-situ environmental gamma-ray spectrometer

    International Nuclear Information System (INIS)

    Terada, Hiromi; Sakai, Eiji; Katagiri, Masaki

    1976-05-01

    A spectrum-to-dose conversion operator value function was obtained for a 73cm 3 closed-end coaxial Ge(Li) in-situ environmental gamma-ray spectrometer; factors influencing the function are considered. (auth.)

  8. Prediction of postoperative pulmonary function following thoracic operations. Value of ventilation-perfusion scanning

    International Nuclear Information System (INIS)

    Bria, W.F.; Kanarek, D.J.; Kazemi, H.

    1983-01-01

    Surgical resection of lung cancer is frequently required in patients with severely impaired lung function resulting from chronic obstructive pulmonary disease. Twenty patients with obstructive lung disease and cancer (mean preoperative forced expiratory volume in 1 second [FEV1] . 1.73 L) were studied preoperatively and postoperatively by spirometry and radionuclide perfusion, single-breath ventilation, and washout techniques to test the ability of these methods to predict preoperatively the partial loss of lung function by the resection. Postoperative FEV1 and forced vital capacity (FVC) were accurately predicted by the formula: postoperative FEV1 (or FVC) . preoperative FEV1 X percent function of regions of lung not to be resected (r . 0.88 and 0.95, respectively). Ventilation and perfusion scans are equally effective in prediction. Washout data add to the sophistication of the method by permitting the qualitative evaluation of ventilation during tidal breathing. Criteria for patients requiring the study are suggested

  9. Value of Gd-EOB-DTPA-enhanced MRI in assessing liver function

    Directory of Open Access Journals (Sweden)

    WANG Lili

    2015-05-01

    Full Text Available ObjectiveTo explore the value of magnetic resonance imaging (MRI specifically enhanced with gadolinium-ethoxybenzyl-diethylenetriamine pentaacetic acid (Gd-EOB-DTPA in assessing the liver function in general population. MethodsUpper abdominal MRI images and Gd-EOB-DTPA-enhanced images, as well as some clinical information, were collected from 41 cases meeting the inclusion and exclusion criteria. Taking the spleen as the control organ, liver-spleen signal intensity contrast (SIliver/spleen and relative liver enhancement (RLE were calculated at 10 min and 20 min after injecting Gd-EOB-DTPA. Differences were evaluated using the independent-samples t-test or Mann-Whitney U test. Corrections were analyzed via Spearman’s rank correlation. ResultsBoth SIliver/spleen at 10 min and 20 min after injection of contrast agent were correlated with Child classification (P<0.05. SIliver/spleen at 20 min had a greater correlation coefficient (r=-0.526 than that at 10 min. The SIliver/spleen with plain scan had no significant correlation with Child classification (P>0.05. RLE at 20 min, but not at 10 min, was correlated with Child classification (r=-0.362, P=0049. Between the cirrhotic and non-cirrhotic groups, SIliver/spleen showed no significant difference (P>0.05. However, SIliver/spleen at 10 min and 20 min, as well as RLE20 min, showed significant differences between the cirrhotic and non-cirrhotic groups (P<0.05. SIliver/spleen at 20 min also exhibited a significant difference between the elevated and normal ALT and TBil groups (both P<0.05. ConclusionGd-EOB-DTPA-enhanced MRI can monitor liver function changes, and SIliver/spleen at 20 min may have an important value in assessing the liver function in general population.

  10. Bronchiolitis obliterans syndrome after single-lung transplantation: impact of time to onset on functional pattern and survival.

    Science.gov (United States)

    Brugière, Olivier; Pessione, Fabienne; Thabut, Gabriel; Mal, Hervé; Jebrak, Gilles; Lesèche, Guy; Fournier, Michel

    2002-06-01

    Among risk factors for the progression of bronchiolitis obliterans syndrome (BOS) after lung transplantation (LT), the influence of time to BOS onset is not known. The aim of the study was to assess if BOS occurring earlier after LT is associated with worse functional prognosis and worse graft survival. We retrospectively compared functional outcome and survival of all single-LT (SLT) recipients who had BOS develop during follow-up in our center according to time to onset of BOS ( or = 3 years after transplantation). Among the 29 SLT recipients with BOS identified during the study period, 20 patients had early-onset BOS and 9 patients had late-onset BOS. The mean decline of FEV(1) over time during the first 9 months in patients with early-onset BOS was significantly greater than in patients with of late-onset BOS (p = 0.04). At last follow-up, patients with early-onset BOS had a lower mean FEV(1) value (25% vs 39% of predicted, p = 0.004), a lower mean PaO(2) value (54 mm Hg vs 73 mm Hg, p = 0.0005), a lower 6-min walk test distance (241 m vs 414 m, p = 0.001), a higher Medical Research Council index value (3.6 vs 1.6, p = 0.0001), and a higher percentage of oxygen dependency (90% vs 11%, p = 0.001) compared with patients with late-onset BOS. In addition, graft survival of patients with early-onset BOS was significantly lower than that of patients with late-onset BOS (log-rank test, p = 0.04). There were 18 of 20 graft failures (90%) in the early-onset BOS group, directly attributable to BOS in all cases (deaths [n = 10] or retransplantation [n = 8]). In the late-onset BOS group, graft failure occurred in four of nine patients due to death from extrapulmonary causes in three of four cases. The median duration of follow-up after occurrence of BOS was not statistically different between patients with early-onset BOS and patients with late-onset BOS (31 +/- 28 months and 37 +/- 26 months, respectively; p = not significant). The subgroup of patients who had BOS develop

  11. Adaptive iterated function systems filter for images highly corrupted with fixed - Value impulse noise

    Science.gov (United States)

    Shanmugavadivu, P.; Eliahim Jeevaraj, P. S.

    2014-06-01

    The Adaptive Iterated Functions Systems (AIFS) Filter presented in this paper has an outstanding potential to attenuate the fixed-value impulse noise in images. This filter has two distinct phases namely noise detection and noise correction which uses Measure of Statistics and Iterated Function Systems (IFS) respectively. The performance of AIFS filter is assessed by three metrics namely, Peak Signal-to-Noise Ratio (PSNR), Mean Structural Similarity Index Matrix (MSSIM) and Human Visual Perception (HVP). The quantitative measures PSNR and MSSIM endorse the merit of this filter in terms of degree of noise suppression and details/edge preservation respectively, in comparison with the high performing filters reported in the recent literature. The qualitative measure HVP confirms the noise suppression ability of the devised filter. This computationally simple noise filter broadly finds application wherein the images are highly degraded by fixed-value impulse noise.

  12. The value of cows in reference populations for genomic selection of new functional traits

    DEFF Research Database (Denmark)

    Buch, Line Hjortø; Kargo, Morten; Berg, Peer

    2012-01-01

    Today, almost all reference populations consist of progeny tested bulls. However, older progeny tested bulls do not have reliable estimated breeding values (EBV) for new traits. Thus, to be able to select for these new traits, it is necessary to build a reference population. We used a deterministic...... of the direct genomic values (DGV) for a new functional trait, regardless of its heritability. For small-scale recording, we compared two scenarios where the reference population consisted of the 2000 cows with phenotypic records or the 30 sires of these cows in the first year with measurements of the new...... to achieve accuracies of the DGV that enable selection for new functional traits recorded on a large scale within 3 years from commencement of recording; and (iv) a higher heritability benefits a reference population of cows more than a reference population of bulls....

  13. Multistability of delayed complex-valued recurrent neural networks with discontinuous real-imaginary-type activation functions

    International Nuclear Information System (INIS)

    Huang Yu-Jiao; Hu Hai-Gen

    2015-01-01

    In this paper, the multistability issue is discussed for delayed complex-valued recurrent neural networks with discontinuous real-imaginary-type activation functions. Based on a fixed theorem and stability definition, sufficient criteria are established for the existence and stability of multiple equilibria of complex-valued recurrent neural networks. The number of stable equilibria is larger than that of real-valued recurrent neural networks, which can be used to achieve high-capacity associative memories. One numerical example is provided to show the effectiveness and superiority of the presented results. (paper)

  14. SYNTHESIS AND REDUCED LOGIC GATE REALIZATION OF MULTI-VALUED LOGIC FUNCTIONS USING NEURAL NETWORK DEPLOYMENT ALGORITHM

    Directory of Open Access Journals (Sweden)

    A. K. CHOWDHURY

    2016-02-01

    Full Text Available In this paper an evolutionary technique for synthesizing Multi-Valued Logic (MVL functions using Neural Network Deployment Algorithm (NNDA is presented. The algorithm is combined with back-propagation learning capability and neural MVL operators. This research article is done to observe the anomalistic characteristics of MVL neural operators and their role in synthesis. The advantages of NNDA-MVL algorithm is demonstrated with realization of synthesized many valued functions with lesser MVL operators. The characteristic feature set consists of MVL gate count, network link count, network propagation delay and accuracy achieved in training. In brief, this paper depicts an effort of reduced network size for synthesized MVL functions. Trained MVL operators improve the basic architecture by reducing MIN gate and interlink connection by 52.94% and 23.38% respectively.

  15. Multi-stage optimization of decision and inhibitory trees for decision tables with many-valued decisions

    KAUST Repository

    Azad, Mohammad

    2017-06-16

    We study problems of optimization of decision and inhibitory trees for decision tables with many-valued decisions. As cost functions, we consider depth, average depth, number of nodes, and number of terminal/nonterminal nodes in trees. Decision tables with many-valued decisions (multi-label decision tables) are often more accurate models for real-life data sets than usual decision tables with single-valued decisions. Inhibitory trees can sometimes capture more information from decision tables than decision trees. In this paper, we create dynamic programming algorithms for multi-stage optimization of trees relative to a sequence of cost functions. We apply these algorithms to prove the existence of totally optimal (simultaneously optimal relative to a number of cost functions) decision and inhibitory trees for some modified decision tables from the UCI Machine Learning Repository.

  16. Multi-stage optimization of decision and inhibitory trees for decision tables with many-valued decisions

    KAUST Repository

    Azad, Mohammad; Moshkov, Mikhail

    2017-01-01

    We study problems of optimization of decision and inhibitory trees for decision tables with many-valued decisions. As cost functions, we consider depth, average depth, number of nodes, and number of terminal/nonterminal nodes in trees. Decision tables with many-valued decisions (multi-label decision tables) are often more accurate models for real-life data sets than usual decision tables with single-valued decisions. Inhibitory trees can sometimes capture more information from decision tables than decision trees. In this paper, we create dynamic programming algorithms for multi-stage optimization of trees relative to a sequence of cost functions. We apply these algorithms to prove the existence of totally optimal (simultaneously optimal relative to a number of cost functions) decision and inhibitory trees for some modified decision tables from the UCI Machine Learning Repository.

  17. Novel method of interpolation and extrapolation of functions by a linear initial value problem

    CSIR Research Space (South Africa)

    Shatalov, M

    2008-09-01

    Full Text Available A novel method of function approximation using an initial value, linear, ordinary differential equation (ODE) is presented. The main advantage of this method is to obtain the approximation expressions in a closed form. This technique can be taught...

  18. The nonlocal boundary value problems for strongly singular higher-order nonlinear functional-differential equations

    Czech Academy of Sciences Publication Activity Database

    Mukhigulashvili, Sulkhan

    -, č. 35 (2015), s. 23-50 ISSN 1126-8042 Institutional support: RVO:67985840 Keywords : higher order functional differential equations * Dirichlet boundary value problem * strong singularity Subject RIV: BA - General Mathematics http://ijpam.uniud.it/online_issue/201535/03-Mukhigulashvili.pdf

  19. A technique of building a value function at the stage of conceptual design of microprocessor systems

    Directory of Open Access Journals (Sweden)

    B. N. Chugaev

    2017-01-01

    Full Text Available The aim of this study is to formalize the selection of optimal technical solutions early in the design of microprocessor-based systems, which allows developers to analyze the recommended solutions, and has, in comparison with the traditional «intuitive» approach, at least two undeniable merits. First, the accepted assumptions and limitations are clearly formed. Secondly, it is defined precisely, in what sense the decision is optimal. When designing microprocessor systems (systems hereafter, several characteristics have to be taken into account at the same time. In general, when n properties are taken into account for each of the compared systems, then the solution of the task of choosing “the best” system depends on choosing a function-criterion. Such function is called a value function in the article. A simple quadratic function is suggested as the value function, it can be interpreted as the distance in Euclidean space of systems technical data. The system, which corresponds to the point nearest to the point characterizing the master system with “limiting” characteristics, is considered the best one. This function approximates the designer’s system of preferences signifi cantly better than a “classical” linear value function. In conclusion, note that the developed recommendations allow the designer of complex technical systems to analyze the proposed solutions in the early stages of design and, in case of disagreement with them, to indicate the reasons why he considers them inadequate. The designed machine optimization of technical solutions in conjunction with the traditional engineering approach should allow more reasonable choosing the structure of systems at the stage of systems conceptual design.

  20. Ability Beliefs, Task Value, and Performance as a Function of Race in a Dart-Throwing Task

    Science.gov (United States)

    Gao, Zan; Kosma, Maria; Harrison, Louis, Jr.

    2009-01-01

    This study examines differences in self-efficacy, expectancy-related beliefs, task value, and performance in a dart-throwing task as a function of race among diverse college students using the expectancy-value model and self-efficacy theory. It also examines the predictive contributions of these beliefs on task performance within each racial…

  1. A single source microwave photonic filter using a novel single-mode fiber to multimode fiber coupling technique.

    Science.gov (United States)

    Chang, John; Fok, Mable P; Meister, James; Prucnal, Paul R

    2013-03-11

    In this paper we present a fully tunable and reconfigurable single-laser multi-tap microwave photonic FIR filter that utilizes a special SM-to-MM combiner to sum the taps. The filter requires only a single laser source for all the taps and a passive component, a SM-to-MM combiner, for incoherent summing of signal. The SM-to-MM combiner does not produce optical interference during signal merging and is phase-insensitive. We experimentally demonstrate an eight-tap filter with both positive and negative programmable coefficients with excellent correspondence between predicted and measured values. The magnitude response shows a clean and accurate function across the entire bandwidth, and proves successful operation of the FIR filter using a SM-to-MM combiner.

  2. Valuing put options on single stock futures: Does the put-call parity relationship hold in the South African derivatives market?

    Directory of Open Access Journals (Sweden)

    A Biebuyck

    2014-12-01

    Full Text Available This study attempts to determine whether mispricing of options on single stock futures is present in the South African derivatives market. The valuation of options on single stock futures is considered through the put-call parity relationship. The theoretical fair values obtained, are compared to the actual market values over a period of three years, that is, from 2009 to 2011. Only put options are considered in this research.The results show that arbitrage put option opportunities do present themselves for the chosen shares. The actual put options were found to be underpriced in 5 out of 6 (83% of the cases considered over the evaluation periods chosen. The mispricing was significant for both the BHP Billiton options with 100% and in the case of Sasol options (66% of the time. Whether profitable arbitrage opportunities is possible, will depend on the magnitude of the mispricing and the transaction fees payable. Further, more extensive research may help identify tendencies which may be of use for the formulation of arbitrage strategies

  3. Improved functional immobilization of llama single-domain antibody fragments to polystyrene surfaces using small peptides

    NARCIS (Netherlands)

    Harmsen, M.M.; Fijten, H.P.D.

    2012-01-01

    We studied the effect of different fusion domains on the functional immobilization of three llama single-domain antibody fragments (VHHs) after passive adsorption to polystyrene in enzyme-linked immunosorbent assays (ELISA). Three VHHs produced without any fusion domain were efficiently adsorbed to

  4. Functionalization of Probe Tips and Supports for Single-Molecule Recognition Force Microscopy

    Science.gov (United States)

    Ebner, Andreas; Wildling, Linda; Zhu, Rong; Rankl, Christian; Haselgrübler, Thomas; Hinterdorfer, Peter; Gruber, Hermann J.

    The measuring tip of a force microscope can be converted into a monomolecular sensor if one or few "ligand" molecules are attached to the apex of the tip while maintaining ligand function. Functionalized tips are used to study fine details of receptor-ligand interaction by force spectroscopy or to map cognate "receptor" molecules on the sample surface. The receptor (or target) molecules can be present on the surface of a biological specimen; alternatively, soluble target molecules must be immobilized on ultraflat supports. This review describes the methods of tip functionalization, as well as target molecule immobilization. Silicon nitride tips, silicon chips, and mica have usually been functionalized in three steps: (1) aminofunctionalization, (2) crosslinker attachment, and (3) ligand/receptor coupling, whereby numerous crosslinkers are available to couple widely different ligand molecules. Gold-covered tips and/or supports have usually been coated with a self-assembled monolayer, on top of which the ligand/receptor molecule has been coupled either directly or via a crosslinker molecule. Apart from these general strategies, many simplified methods have been used for tip and/or support functionalization, even single-step methods such as adsorption or chemisorption being very efficient under suitable circumstances. All methods are described with the same explicitness and critical parameters are discussed. In conclusion, this review should help to find suitable methods for specific problems of tip and support functionalization.

  5. Determination of myocardial FFA elimination rates by functional images of uncorrected half-time values

    International Nuclear Information System (INIS)

    Visser, F.C.; Eenige, M.J. van; Wall, E.E. van der; Roos, J.P.; Lingen, A. van; Westera, G.; Hollander, W. den; Heidendal, G.A.K.

    1984-01-01

    This paper presents an alternative method of demarcating regions of interest over the myocardium after administration of 123 I-heptadecanoic acid to patients with coronary artery disease. In a matrix of 32x32 pixels the elimination rates of the radioactivity, which are not corrected for background activity, are visualized per pixel in a functional image. The functional image showed areas in the myocardium with high values of uncorrected elimination rates. These areas corresponded with the tracer defects on the scintigram. Corrected elimination rates obtained from regions of interest of functional images were comparable with those of scintigrams. Thus based on functional images of uncorrected elimination rates a reliable, objective determination of regions of interest over normal and abnormal myocardium can be made. (orig.) [de

  6. Defect spectroscopy of single ZnO microwires

    Science.gov (United States)

    Villafuerte, M.; Ferreyra, J. M.; Zapata, C.; Barzola-Quiquia, J.; Iikawa, F.; Esquinazi, P.; Heluani, S. P.; de Lima, M. M.; Cantarero, A.

    2014-04-01

    The point defects of single ZnO microwires grown by carbothermal reduction were studied by microphotoluminescence, photoresistance excitation spectra, and resistance as a function of the temperature. We found the deep level defect density profile along the microwire showing that the concentration of defects decreases from the base to the tip of the microwires and this effect correlates with a band gap narrowing. The results show a characteristic deep defect levels inside the gap at 0.88 eV from the top of the VB. The resistance as a function of the temperature shows defect levels next to the bottom of the CB at 110 meV and a mean defect concentration of 4 × 1018 cm-3. This combination of techniques allows us to study the band gap values and defects states inside the gap in single ZnO microwires and opens the possibility to be used as a defect spectroscopy method.

  7. On the contact values of the density profiles in an electric double layer using density functional theory

    Directory of Open Access Journals (Sweden)

    L.B. Bhuiyan

    2012-06-01

    Full Text Available A recently proposed, local second contact value theorem [Henderson D., Boda D., J. Electroanal. Chem., 2005, Vol. 582, 16] for the charge profile of an electric double layer is used in conjunction with existing Monte Carlo data from the literature to assess the contact behavior of the electrode-ion distributions predicted by the density functional theory. The results for the contact values of the co- and counterion distributions and their product are obtained for the symmetric valency, restricted primitive model planar double layer for a range of electrolyte concentrations and temperatures. Overall the theoretical results satisfy the second contact value theorem reasonably well the agreement with the simulations being semi-quantitative or better. The product of the co- and counterion contact values as a function of the electrode surface charge density is qualitative with the simulations with increasing deviations at higher concentrations.

  8. The electrochemical signature of functionalized single-walled carbon nanotubes bearing electroactive groups

    International Nuclear Information System (INIS)

    Le Floch, Fabien; Thuaire, Aurelie; Simonato, Jean-Pierre; Bidan, Gerard

    2009-01-01

    We report the modification and characterization of single-walled carbon nanotubes (SWCNTs) in view of molecular sensing applications. We found that ultrasonicated SWCNTs present sticking properties that make them adhere on electrode surfaces. This allows excellent characterization of SWCNTs by cyclic voltammetry (CV) before and after chemical functionalization with diazonium salts bearing electroactive groups. Bare SWCNTs presented distinct invariant shapes in CV, used as control curves, in comparison with functionalized SWCNTs for which specific signatures corresponding to the presence of grafted molecules were identified. According to the electronic substituents in the para position of the diazonium salts, divergent behaviours were observed for the grafting reactions. Diazonium salts having electrowithdrawing groups could be grafted without electrochemical induction whereas those bearing electron donating groups required a cathodic potential to generate the formation of the radical species.

  9. The electrochemical signature of functionalized single-walled carbon nanotubes bearing electroactive groups

    Energy Technology Data Exchange (ETDEWEB)

    Le Floch, Fabien; Thuaire, Aurelie; Simonato, Jean-Pierre [LITEN/DTNM/LCRE, CEA-Grenoble 17 rue des Martyrs, 38054 Grenoble cedex 9 (France); Bidan, Gerard [INAC/DIR, CEA-Grenoble 17 rue des Martyrs, 38054 Grenoble cedex 9 (France)], E-mail: jean-pierre.simonato@cea.fr

    2009-04-08

    We report the modification and characterization of single-walled carbon nanotubes (SWCNTs) in view of molecular sensing applications. We found that ultrasonicated SWCNTs present sticking properties that make them adhere on electrode surfaces. This allows excellent characterization of SWCNTs by cyclic voltammetry (CV) before and after chemical functionalization with diazonium salts bearing electroactive groups. Bare SWCNTs presented distinct invariant shapes in CV, used as control curves, in comparison with functionalized SWCNTs for which specific signatures corresponding to the presence of grafted molecules were identified. According to the electronic substituents in the para position of the diazonium salts, divergent behaviours were observed for the grafting reactions. Diazonium salts having electrowithdrawing groups could be grafted without electrochemical induction whereas those bearing electron donating groups required a cathodic potential to generate the formation of the radical species.

  10. Wiener-Hopf operators on spaces of functions on R+ with values in a Hilbert space

    OpenAIRE

    Petkova, Violeta

    2006-01-01

    A Wiener-Hopf operator on a Banach space of functions on R+ is a bounded operator T such that P^+S_{-a}TS_a=T, for every positive a, where S_a is the operator of translation by a. We obtain a representation theorem for the Wiener-Hopf operators on a large class of functions on R+ with values in a separable Hilbert space.

  11. Use of Green's functions in the numerical solution of two-point boundary value problems

    Science.gov (United States)

    Gallaher, L. J.; Perlin, I. E.

    1974-01-01

    This study investigates the use of Green's functions in the numerical solution of the two-point boundary value problem. The first part deals with the role of the Green's function in solving both linear and nonlinear second order ordinary differential equations with boundary conditions and systems of such equations. The second part describes procedures for numerical construction of Green's functions and considers briefly the conditions for their existence. Finally, there is a description of some numerical experiments using nonlinear problems for which the known existence, uniqueness or convergence theorems do not apply. Examples here include some problems in finding rendezvous orbits of the restricted three body system.

  12. Corrections to the free-nucleon values of the single-particle matrix elements of the M1 and Gamow-Teller operators, from a comparison of shell-model predictions with sd-shell data

    International Nuclear Information System (INIS)

    Brown, B.A.; Wildenthal, B.H.

    1983-01-01

    The magnetic dipole moments of states in mirror pairs of the sd-shell nuclei and the strengths of the Gamow-Teller beta decays which connect them are compared with predictions based on mixed-configuration shell-model wave functions. From this analysis we extract the average effective values of the single-particle matrix elements of the l, s, and [Y/sup( 2 )xs]/sup( 1 ) components of the M1 and Gamow-Teller operators acting on nucleons in the 0d/sub 5/2/, 1s/sub 1/2/, and 0d/sub 3/2/ orbits. These results are compared with the recent calculations by Towner and Khanna of the corrections to the free-nucleon values of these matrix elements which arise from the effects of isobar currents, mesonic-exchange currents, and mixing with configurations outside the sd shell

  13. Quantifying urban forest structure, function, and value: the Chicago Urban Forest Climate Project

    Science.gov (United States)

    E. Gregory McPherson; David Nowak; Gordon Heisler; Sue Grimmond; Catherine Souch; Rich Grant; Rowan Rowntree

    1997-01-01

    This paper is a review of research in Chicago that linked analyses of vegetation structure with forest functions and values. During 1991, the region's trees removed an estimated 5575 metric tons of air pollutants, providing air cleansing worth $9.2 million. Each year they sequester an estimated 315 800 metric tons of carbon. Increasing tree cover 10% or planting...

  14. The function of single containment and double containment of PWR nuclear power plant

    International Nuclear Information System (INIS)

    Chen Weijing.

    1985-01-01

    The function and structures of single containment and double containment of PWR nuclear power plant were described briefiy. The dissimilarites of diffent type of containments, which effects the impact of environment are discused. The impact of environment, effected by 'source term', containment gas leak rate and diffusion pattern of the released gas, under different operating condition is analysed. Especially, the impact of environment under LOCA accident is fully analysed

  15. Parasitic neutron bragg reflections from large imperfect single crystals

    Energy Technology Data Exchange (ETDEWEB)

    Naguib, K.; Adib, M

    1998-12-01

    A formula is given which allows to calculate the contribution of the total Bragg scattering from different (hkl) planes to the neutron transmission through a large imperfect single crystals. The formula takes into account the crystal structure type, its mosaic spread value, the plane along which the crystal surface is cut along and its orientation with respect to the neutron beam direction. A computer program ISCANF-1 was developed to calculate the total parasitic scattering cross-section from different (hkl) planes as well as the nuclear and diffuse scattering cross-sections. The ISCANF-1 program was applied to calculate the neutron attenuation through Cu and Zn single crystals, each of them cut along (002) planes. The calculated values of the neutron transmission through Cu and Zn crystals were compared with the measured ones in the wavelength range 0.21-0.47 nm and 0.04-0.52 nm respectively. The measured and calculated values were found to be in reasonable agreement within the statistical accuracy. The computer program ISCANF-1 was also applied to investigate the effect of parasitic Bragg scattering on the neutron filtering characteristics of both Zn and Cu single crystals as a function of their physical parameters.

  16. Parasitic neutron bragg reflections from large imperfect single crystals

    International Nuclear Information System (INIS)

    Naguib, K.; Adib, M.

    1998-01-01

    A formula is given which allows to calculate the contribution of the total Bragg scattering from different (hkl) planes to the neutron transmission through a large imperfect single crystals. The formula takes into account the crystal structure type, its mosaic spread value, the plane along which the crystal surface is cut along and its orientation with respect to the neutron beam direction. A computer program ISCANF-1 was developed to calculate the total parasitic scattering cross-section from different (hkl) planes as well as the nuclear and diffuse scattering cross-sections. The ISCANF-1 program was applied to calculate the neutron attenuation through Cu and Zn single crystals, each of them cut along (002) planes. The calculated values of the neutron transmission through Cu and Zn crystals were compared with the measured ones in the wavelength range 0.21-0.47 nm and 0.04-0.52 nm respectively. The measured and calculated values were found to be in reasonable agreement within the statistical accuracy. The computer program ISCANF-1 was also applied to investigate the effect of parasitic Bragg scattering on the neutron filtering characteristics of both Zn and Cu single crystals as a function of their physical parameters

  17. Single vortex states in a confined Bose-Einstein condensate

    International Nuclear Information System (INIS)

    Komineas, S.; Cooper, N. R.; Papanicolaou, N.

    2005-01-01

    It has been demonstrated experimentally that non-axisymmetric vortices precess around the center of a Bose-Einstein condensate. Two types of single vortex states have been observed, usually referred to as the S vortex and the U vortex. We study theoretically the single vortex excitations in spherical and elongated condensates as a function of the interaction strength. We solve numerically the Gross-Pitaevskii equation and calculate the angular momentum as a function of precession frequency. The existence of two types of vortices means that we have two different precession frequencies for each angular momentum value. As the interaction strength increases the vortex lines bend and the precession frequencies shift to lower values. We establish that for given angular momentum the S vortex has higher energy than the U vortex in a rotating elongated condensate. We show that the S vortex is related to the solitonic vortex, which is a nonlinear excitation in the nonrotating system. For small interaction strengths the S vortex is related to the dark soliton. In the dilute limit a lowest Landau level calculation provides an analytic description of these vortex modes in terms of the harmonic oscillator states

  18. Multi-valued logic circuits using hybrid circuit consisting of three gates single-electron transistors (TG-SETs) and MOSFETs.

    Science.gov (United States)

    Shin, SeungJun; Yu, YunSeop; Choi, JungBum

    2008-10-01

    New multi-valued logic (MVL) families using the hybrid circuits consisting of three gates single-electron transistors (TG-SETs) and a metal-oxide-semiconductor field-effect transistor (MOSFET) are proposed. The use of SETs offers periodic literal characteristics due to Coulomb oscillation of SET, which allows a realization of binary logic (BL) circuits as well as multi-valued logic (MVL) circuits. The basic operations of the proposed MVL families are successfully confirmed through SPICE circuit simulation based on the physical device model of a TG-SET. The proposed MVL circuits are found to be much faster, but much larger power consumption than a previously reported MVL, and they have a trade-off between speed and power consumption. As an example to apply the newly developed MVL families, a half-adder is introduced.

  19. Ensembles of indium phosphide nanowires: physical properties and functional devices integrated on non-single crystal platforms

    International Nuclear Information System (INIS)

    Kobayashi, Nobuhiko P.; Lohn, Andrew; Onishi, Takehiro; Mathai, Sagi; Li, Xuema; Straznicky, Joseph; Wang, Shih-Yuan; Williams, R.S.; Logeeswaran, V.J.; Islam, M.S.

    2009-01-01

    A new route to grow an ensemble of indium phosphide single-crystal semiconductor nanowires is described. Unlike conventional epitaxial growth of single-crystal semiconductor films, the proposed route for growing semiconductor nanowires does not require a single-crystal semiconductor substrate. In the proposed route, instead of using single-crystal semiconductor substrates that are characterized by their long-range atomic ordering, a template layer that possesses short-range atomic ordering prepared on a non-single-crystal substrate is employed. On the template layer, epitaxial information associated with its short-range atomic ordering is available within an area that is comparable to that of a nanowire root. Thus the template layer locally provides epitaxial information required for the growth of semiconductor nanowires. In the particular demonstration described in this paper, hydrogenated silicon was used as a template layer for epitaxial growth of indium phosphide nanowires. The indium phosphide nanowires grown on the hydrogenerated silicon template layer were found to be single crystal and optically active. Simple photoconductors and pin-diodes were fabricated and tested with the view towards various optoelectronic device applications where group III-V compound semiconductors are functionally integrated onto non-single-crystal platforms. (orig.)

  20. Ensembles of indium phosphide nanowires: physical properties and functional devices integrated on non-single crystal platforms

    Energy Technology Data Exchange (ETDEWEB)

    Kobayashi, Nobuhiko P.; Lohn, Andrew; Onishi, Takehiro [University of California, Santa Cruz (United States). Baskin School of Engineering; NASA Ames Research Center, Nanostructured Energy Conversion Technology and Research (NECTAR), Advanced Studies Laboratories, Univ. of California Santa Cruz, Moffett Field, CA (United States); Mathai, Sagi; Li, Xuema; Straznicky, Joseph; Wang, Shih-Yuan; Williams, R.S. [Hewlett-Packard Laboratories, Information and Quantum Systems Laboratory, Palo Alto, CA (United States); Logeeswaran, V.J.; Islam, M.S. [University of California Davis, Electrical and Computer Engineering, Davis, CA (United States)

    2009-06-15

    A new route to grow an ensemble of indium phosphide single-crystal semiconductor nanowires is described. Unlike conventional epitaxial growth of single-crystal semiconductor films, the proposed route for growing semiconductor nanowires does not require a single-crystal semiconductor substrate. In the proposed route, instead of using single-crystal semiconductor substrates that are characterized by their long-range atomic ordering, a template layer that possesses short-range atomic ordering prepared on a non-single-crystal substrate is employed. On the template layer, epitaxial information associated with its short-range atomic ordering is available within an area that is comparable to that of a nanowire root. Thus the template layer locally provides epitaxial information required for the growth of semiconductor nanowires. In the particular demonstration described in this paper, hydrogenated silicon was used as a template layer for epitaxial growth of indium phosphide nanowires. The indium phosphide nanowires grown on the hydrogenerated silicon template layer were found to be single crystal and optically active. Simple photoconductors and pin-diodes were fabricated and tested with the view towards various optoelectronic device applications where group III-V compound semiconductors are functionally integrated onto non-single-crystal platforms. (orig.)

  1. Large work function difference driven electron transfer from electrides to single-walled carbon nanotubes

    KAUST Repository

    Menamparambath, Mini Mol; Park, Jong Ho; Yoo, Ho Sung; Patole, Shashikant P.; Yoo, Ji Beom; Kim, Sung Wng; Baik, Seunghyun

    2014-01-01

    V. Here we investigated charge transfer between two different types of electrides, [Ca2N]+·e- and [Ca 24Al28O64]4+·4e-, and single-walled carbon nanotubes (SWNTs) with a work function of 4.73-5.05 eV. [Ca2N]+·e- with open 2-dimensional electron layers

  2. Quantifying recreational value and the functional relationship between travel cost and visiting national park

    DEFF Research Database (Denmark)

    Kawsar, Mahidi Hasan; Al Pavel, Muha Abdullah; Uddin, Mohammad Belal

    2015-01-01

    Estimation of recreational benefits is an important tool for both biodiversity conservation and ecotourism development in national parks and sanctuaries. The design of this work is to estimate the recreational value and to establish functional relationship between travel cost and visitation...... of Lawachara National Park (LNP) in Bangladesh. This study employed zonal approach of the travel cost method. The work is grounded on a sample of 422 visitors of the LNP. Results showed that the total value of environmental assets of the LNP is 55,694,173 Taka/Year. Moreover, our suggestion based on visitors...

  3. The value of ventilation scintigraphy after single lung transplantation

    NARCIS (Netherlands)

    Ouwens, JP; van der Bij, W; van der Mark, TW; Piers, DA; Koeter, GH

    Background: A decrease in forced expiratory volume in 1 second (FEV1) as a diagnostic criterion for bronchiolitis obliterans syndrome (BOS) after single lung transplantation may be influenced significantly by the presence of the native lung. To quantify and to discriminate between the relative

  4. Family socioeconomic status and child executive functions: the roles of language, home environment, and single parenthood.

    Science.gov (United States)

    Sarsour, Khaled; Sheridan, Margaret; Jutte, Douglas; Nuru-Jeter, Amani; Hinshaw, Stephen; Boyce, W Thomas

    2011-01-01

    The association between family socioeconomic status (SES) and child executive functions is well-documented. However, few studies have examined the role of potential mediators and moderators. We studied the independent and interactive associations between family SES and single parenthood to predict child executive functions of inhibitory control, cognitive flexibility, and working memory and examined child expressive language abilities and family home environment as potential mediators of these associations. Sixty families from diverse SES backgrounds with a school-age target child (mean [SD] age = 9.9 [0.96] years) were evaluated. Child executive functioning was measured using a brief battery. The quality of the home environment was evaluated using the Home Observation for the Measurement of the Environment inventory. Family SES predicted the three child executive functions under study. Single parent and family SES were interactively associated with children's inhibitory control and cognitive flexibility; such that children from low SES families who were living with one parent performed less well on executive function tests than children from similarly low SES who were living with two parents. Parental responsivity, enrichment activities and family companionship mediated the association between family SES and child inhibitory control and working memory. This study demonstrates that family SES inequalities are associated with inequalities in home environments and with inequalities in child executive functions. The impact of these disparities as they unfold in the lives of typically developing children merits further investigation and understanding.

  5. The predictive value of respiratory function tests for non-invasive ventilation in amyotrophic lateral sclerosis.

    Science.gov (United States)

    Tilanus, T B M; Groothuis, J T; TenBroek-Pastoor, J M C; Feuth, T B; Heijdra, Y F; Slenders, J P L; Doorduin, J; Van Engelen, B G; Kampelmacher, M J; Raaphorst, J

    2017-07-25

    Non-invasive ventilation (NIV) improves survival and quality of life in amyotrophic lateral sclerosis (ALS) patients. The timing of referral to a home ventilation service (HVS), which is in part based on respiratory function tests, has shown room for improvement. It is currently unknown which respiratory function test predicts an appropriate timing of the initiation of NIV. We analysed, retrospectively, serial data of five respiratory function tests: forced vital capacity (FVC), peak cough flow (PCF), maximum inspiratory and expiratory pressure (MIP and MEP) and sniff nasal inspiratory pressure (SNIP) in patients with ALS. Patients who had had at least one assessment of respiratory function and one visit at the HVS, were included. Our aim was to detect the test with the highest predictive value for the need for elective NIV in the following 3 months. We analysed time curves, currently used cut-off values for referral, and respiratory function test results between 'NIV indication' and 'no-NIV indication' patients. One hundred ten patients with ALS were included of whom 87 received an NIV indication; 11.5% had one assessment before receiving an NIV indication, 88.5% had two or more assessments. The NIV indication was based on complaints of hypoventilation and/or proven (nocturnal) hypercapnia. The five respiratory function tests showed a descending trend during disease progression, where SNIP showed the greatest decline within the latest 3 months before NIV indication (mean = -22%). PCF at the time of referral to the HVS significantly discriminated between the groups 'NIV-indication' and 'no NIV-indication yet' patients at the first HVS visit: 259 (±92) vs. 348 (±137) L/min, p = 0.019. PCF and SNIP showed the best predictive characteristics in terms of sensitivity. SNIP showed the greatest decline prior to NIV indication and PCF significantly differentiated 'NIV-indication' from 'no NIV-indication yet' patients with ALS. Currently used cut-off values might be

  6. Spatial resolution of 2D ionization chamber arrays for IMRT dose verification: single-detector size and sampling step width

    International Nuclear Information System (INIS)

    Poppe, Bjoern; Djouguela, Armand; Blechschmidt, Arne; Willborn, Kay; Ruehmann, Antje; Harder, Dietrich

    2007-01-01

    The spatial resolution of 2D detector arrays equipped with ionization chambers or diodes, used for the dose verification of IMRT treatment plans, is limited by the size of the single detector and the centre-to-centre distance between the detectors. Optimization criteria with regard to these parameters have been developed by combining concepts of dosimetry and pattern analysis. The 2D-ARRAY Type 10024 (PTW-Freiburg, Germany), single-chamber cross section 5 x 5 mm 2 , centre-to-centre distance between chambers in each row and column 10 mm, served as an example. Additional frames of given dose distributions can be taken by shifting the whole array parallel or perpendicular to the MLC leaves by, e.g., 5 mm. The size of the single detector is characterized by its lateral response function, a trapezoid with 5 mm top width and 9 mm base width. Therefore, values measured with the 2D array are regarded as sample values from the convolution product of the accelerator generated dose distribution and this lateral response function. Consequently, the dose verification, e.g., by means of the gamma index, is performed by comparing the measured values of the 2D array with the values of the convolution product of the treatment planning system (TPS) calculated dose distribution and the single-detector lateral response function. Sufficiently small misalignments of the measured dose distributions in comparison with the calculated ones can be detected since the lateral response function is symmetric with respect to the centre of the chamber, and the change of dose gradients due to the convolution is sufficiently small. The sampling step width of the 2D array should provide a set of sample values representative of the sampled distribution, which is achieved if the highest spatial frequency contained in this function does not exceed the 'Nyquist frequency', one half of the sampling frequency. Since the convolution products of IMRT-typical dose distributions and the single

  7. Prospective Teachers' Reactions to "Right-or-Wrong" Tasks: The Case of Derivatives of Absolute Value Functions

    Science.gov (United States)

    Tsamir, Pessia; Rasslan, Shaker; Dreyfus, Tommy

    2006-01-01

    This paper illustrates the role of a "Thinking-about-Derivatives" task in identifying learners' derivative conceptions and for promoting their critical thinking about derivatives of absolute value functions. The task included three parts: "Define" the derivative of a function f(x) at x = x[subscript 0], "Solve-if-Possible" the derivative of f(x) =…

  8. The predictive value of single-photon emission computed tomography/computed tomography for sentinel lymph node localization in head and neck cutaneous malignancy.

    Science.gov (United States)

    Remenschneider, Aaron K; Dilger, Amanda E; Wang, Yingbing; Palmer, Edwin L; Scott, James A; Emerick, Kevin S

    2015-04-01

    Preoperative localization of sentinel lymph nodes in head and neck cutaneous malignancies can be aided by single-photon emission computed tomography/computed tomography (SPECT/CT); however, its true predictive value for identifying lymph nodes intraoperatively remains unquantified. This study aims to understand the sensitivity, specificity, and positive and negative predictive values of SPECT/CT in sentinel lymph node biopsy for cutaneous malignancies of the head and neck. Blinded retrospective imaging review with comparison to intraoperative gamma probe confirmed sentinel lymph nodes. A consecutive series of patients with a head and neck cutaneous malignancy underwent preoperative SPECT/CT followed by sentinel lymph node biopsy with a gamma probe. Two nuclear medicine physicians, blinded to clinical data, independently reviewed each SPECT/CT. Activity within radiographically defined nodal basins was recorded and compared to intraoperative gamma probe findings. Sensitivity, specificity, and negative and positive predictive values were calculated with subgroup stratification by primary tumor site. Ninety-two imaging reads were performed on 47 patients with cutaneous malignancy who underwent SPECT/CT followed by sentinel lymph node biopsy. Overall sensitivity was 73%, specificity 92%, positive predictive value 54%, and negative predictive value 96%. The predictive ability of SPECT/CT to identify the basin or an adjacent basin containing the single hottest node was 92%. SPECT/CT overestimated uptake by an average of one nodal basin. In the head and neck, SPECT/CT has higher reliability for primary lesions of the eyelid, scalp, and cheek. SPECT/CT has high sensitivity, specificity, and negative predictive value, but may overestimate relevant nodal basins in sentinel lymph node biopsy. © 2014 The American Laryngological, Rhinological and Otological Society, Inc.

  9. Age-independent anti-Müllerian hormone (AMH) standard deviation scores to estimate ovarian function.

    Science.gov (United States)

    Helden, Josef van; Weiskirchen, Ralf

    2017-06-01

    To determine single year age-specific anti-Müllerian hormone (AMH) standard deviation scores (SDS) for women associated to normal ovarian function and different ovarian disorders resulting in sub- or infertility. Determination of particular year median and mean AMH values with standard deviations (SD), calculation of age-independent cut off SDS for the discrimination between normal ovarian function and ovarian disorders. Single-year-specific median, mean, and SD values have been evaluated for the Beckman Access AMH immunoassay. While the decrease of both median and mean AMH values is strongly correlated with increasing age, calculated SDS values have been shown to be age independent with the differentiation between normal ovarian function measured as occurred ovulation with sufficient luteal activity compared with hyperandrogenemic cycle disorders or anovulation associated with high AMH values and reduced ovarian activity or insufficiency associated with low AMH, respectively. These results will be helpful for the treatment of patients and the ventilation of the different reproductive options. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Functionalization of silicon-doped single walled carbon nanotubes at the doping site: An ab initio study

    International Nuclear Information System (INIS)

    Song Chen; Xia Yueyuan; Zhao Mingwen; Liu Xiangdong; Li Feng; Huang Boda; Zhang Hongyu; Zhang Bingyun

    2006-01-01

    We performed ab initio calculations on the cytosine-functionalized silicon-doped single walled carbon nanotubes (SWNT). The results show that silicon substitutional doping to SWNT can dramatically change the atomic and electronic structures of the SWNT. And more importantly, it may provide an efficient pathway for further sidewall functionalization to synthesize more complicated SWNT based complex materials, for example, our previously proposed base-functionalized SWNTs, because the doping silicon atom can improve the reaction activity of the tube at the doping site due to its preference to form sp3 hybridization bonding

  11. Chemi- vs physisorption in the radical functionalization of single-walled carbon nanotubes under microwaves

    Directory of Open Access Journals (Sweden)

    Victor Mamane

    2014-04-01

    Full Text Available The effect of microwaves on the functionalization of single-walled carbon nanotubes (SWNTs by the diazonium method was studied. The usage of a new approach led to the identification of the strength of the interaction (physical or chemical between the functional groups and the carbon nanotube surface. Moreover, the nature (chemical formula of the adsorbed/grafted functional groups was determined. According to thermogravimetric analysis coupled with mass spectrometry and Raman spectroscopy, the optimal functionalization level was reached after 5 min of reaction. Prolonged reaction times can lead to undesired reactions such as defunctionalization, solvent addition and polymerization of the grafted functions. The strength (chemi- vs physisorption of the bonds between the grafted functional groups and the SWNTs is discussed showing the occurrence of physical adsorption as a consequence of defunctionalization after 15 min of reaction under microwaves. Several chemical mechanisms of grafting could be identified, and it was possible to distinguish conditions leading to the desired chemical grafting from those leading to undesired reactions such as physisorption and polymerization.

  12. Assessment of left ventricular function with single breath-hold highly accelerated cine MRI combined with guide-point modeling

    International Nuclear Information System (INIS)

    Heilmaier, Christina; Nassenstein, Kai; Nielles-Vallespin, Sonia; Zuehlsdorff, Sven; Hunold, Peter; Barkhausen, Joerg

    2010-01-01

    Purpose: To prospectively assess the performance of highly accelerated cine MRI in multi-orientations combined with a new guide-point modeling post-processing technique (GPM approach) for assessment of left ventricular (LV) function compared to the standard summation of slices method based on a stack of short axis views (SoS approach). Materials and methods: 33 consecutive patients were examined on a 1.5 T scanner with a standard steady state free precession (SSFP) sequence (TR, 3.0 ms; TE, 1.5 m; flip angle (FA), 60 o ; acceleration factor (AF), 2) analyzed with the SoS method and a highly accelerated, single breath-hold temporal parallel acquisition SSFP sequence (TR, 4.6 ms; TE, 1.1 ms; AF, 3) post-processed with the GPM method. LV function values were measured by two independent readers with different experience in cardiac MRI and compared by using the paired t-test and F-test. Inter- and intraobserver agreements were calculated using Bland-Altman-Plots. Results: Mean acquisition and post-processing time was significantly shorter with the GPM approach (15 s/3 min versus 360 s/6 min). For all LV function parameters interobserver agreement between the experienced and non-experienced reader was significantly improved when the GPM approach was used. However, end-diastolic and end-systolic volumes were larger for the GPM technique when compared to the SoS method (P 0.121). In both readers and for all parameters variances did not differ significantly (P ≥ 0.409) and the two approaches showed an excellent linear correlation (r > 0.951). Conclusion: Due to its accurate, fast and reproducible assessment of LV function parameters highly accelerated MRI combined with the GPM technique may become the technique of first choice for assessment of LV function in clinical routine.

  13. Single and multi-frequency impedance characterization of symmetric activated carbon single capacitor cells

    Directory of Open Access Journals (Sweden)

    Suzana Sopčić

    2018-05-01

    Full Text Available Electrochemical impedance spectroscopy (EIS technique is used for characterization of single cell symmetric capacitors having different mass loadings of activated carbon (AC. Relevant values of charge storage capacitance (CT and internal resistance (ESR were evaluated by the single frequency and multi-frequency analyses of measured impedance spectra. Curve fittings were based on the non-ideal R-C model that takes into account the parasitic inductance, contributions from electrode materials/contacts and the effects of AC porosity. Higher CT and lower ESR values were obtained not only for the cell with higher mass of AC, but also using the single vs. multi-frequency approach. Lower CT and higher values of ESR that are generally obtained using the multi-frequency method and curve fittings should be related to the not ideal capacitive response of porous AC material and too high frequency chosen in applying the single frequency analysis.

  14. Extensions of vector-valued Baire one functions with preservation of points of continuity

    Czech Academy of Sciences Publication Activity Database

    Koc, M.; Kolář, Jan

    2016-01-01

    Roč. 442, č. 1 (2016), s. 138-148 ISSN 0022-247X R&D Projects: GA ČR(CZ) GA14-07880S Institutional support: RVO:67985840 Keywords : vector-valued Baire one functions * extensions * non-tangential limit * continuity points Subject RIV: BA - General Mathematics Impact factor: 1.064, year: 2016 http://www.sciencedirect.com/science/article/pii/S0022247X1630097X

  15. Proposal for determining changes in entropy of semi ideal gas using mean values of temperature functions

    Directory of Open Access Journals (Sweden)

    Pejović Branko B.

    2014-01-01

    Full Text Available In a semi-ideal gas, entropy changes cannot be determined through the medium specific heat capacity in a manner as determined by the change of internal energy and enthalpy, i.e. the amount of heat exchanged. Taking this into account, the authors conducted two models through which it is possible to determine the change in the specific entropy of a semi-ideal gas for arbitrary temperature interval using the spread sheet method, using the mean values of the appropriate functions. The idea is to replace integration, which occurs here in evitably, with mean values of the previous functions. The models are derived based on the functional dependence of the actual specific heat capacity on the temperature. The theorem used is that of the mean value of a function as well as the mathematical properties of the definite integral. The mean value of a fractional function is determined via its integrand while the logarithmic functions were performed by applying a suitable transformation of the differential calculus. The relations derived relation, using the computer program, have enabled the design of appropriate thermodynamic tables through which it is possible to determine the change in entropy of arbitrary state changes in an efficient and rational manner, without the use of calculus or finished forms. In this way, the change in the entropy of a semi-ideal gas is determined for an arbitrary temperature interval using the method which is analogous to that applied in determining the change of internal energy and enthalpy or the amount of heat exchanged, which was the goal of the work. Verification of the proposed method for both the above functions was performed for a a few characteristic semi-ideal gases where change c(T is significant, for the three adopted temperature intervals, for the characteristic change of state. This was compared to the results of the classical integral and the proposed method through the prepared tables. In certain or special cases

  16. The exact value of Jung constants in a class of Orlicz function spaces

    OpenAIRE

    Yan, Y. Q.

    2005-01-01

    Let $\\Phi$ be an $N$-function. Then the Jung constants of the Orlicz function spaces $L^\\Phi[0,1]$ generated by $\\Phi$, equipped with the Luxemburg and Orlicz norms, have the following exact values: \\item{(i)} if $F_\\Phi(t)=t\\varphi(t)/\\Phi(t)$ is decreasing and $1 < C_\\Phi < 2$, then $$ JC(L^{(\\Phi)}[0,1])=JC(L^\\Phi[0,1])=2^{1/C_\\Phi-1}; $$ \\item{(ii)} if $F_\\Phi(t)$ is increasing and $C_\\Phi > 2$, then $$ JC(L^{(\\Phi)}[0,1])=JC(L^\\Phi[0,1])=2^{-1/C_\\Phi}, $$ where $$C_\\Phi=\\lim_{t\\to...

  17. The evolutionary value of recombination is constrained by genome modularity.

    Directory of Open Access Journals (Sweden)

    Darren P Martin

    2005-10-01

    Full Text Available Genetic recombination is a fundamental evolutionary mechanism promoting biological adaptation. Using engineered recombinants of the small single-stranded DNA plant virus, Maize streak virus (MSV, we experimentally demonstrate that fragments of genetic material only function optimally if they reside within genomes similar to those in which they evolved. The degree of similarity necessary for optimal functionality is correlated with the complexity of intragenomic interaction networks within which genome fragments must function. There is a striking correlation between our experimental results and the types of MSV recombinants that are detectable in nature, indicating that obligatory maintenance of intragenome interaction networks strongly constrains the evolutionary value of recombination for this virus and probably for genomes in general.

  18. Generalizing the DGLAP evolution of fragmentation functions to the smallest x values

    International Nuclear Information System (INIS)

    Albino, S.; Kniehl, B.A.; Kramer, G.; Ochs, W.

    2005-03-01

    An approach which unifies the double logarithmic approximation at small x and the leading order DGLAP evolution of fragmentation functions at large x is presented. This approach reproduces exactly the modified leading logarithm approximation, but is more complete due to the degrees of freedom given to the quark sector and the inclusion of the fixed order terms. We find that data from the largest x values to the peak region can be better fitted than with other approaches. (orig.)

  19. Time-dependent importance sampling in semiclassical initial value representation calculations for time correlation functions.

    Science.gov (United States)

    Tao, Guohua; Miller, William H

    2011-07-14

    An efficient time-dependent importance sampling method is developed for the Monte Carlo calculation of time correlation functions via the initial value representation (IVR) of semiclassical (SC) theory. A prefactor-free time-dependent sampling function weights the importance of a trajectory based on the magnitude of its contribution to the time correlation function, and global trial moves are used to facilitate the efficient sampling the phase space of initial conditions. The method can be generally applied to sampling rare events efficiently while avoiding being trapped in a local region of the phase space. Results presented in the paper for two system-bath models demonstrate the efficiency of this new importance sampling method for full SC-IVR calculations.

  20. Variables of Which Values Are a Function

    Science.gov (United States)

    Leigland, Sam

    2005-01-01

    The ordinary-language concept of values has a complex history in psychology and in science generally. The traditional fact-value distinction commonly found in traditional scientific perspectives has been challenged by the varieties of philosophical pragmatism, which have similarities to Skinner's radical behaviorism. Skinner's challenge to the…

  1. Nonlinear polarization effects in a birefringent single mode optical fiber

    International Nuclear Information System (INIS)

    Ishiekwene, G.C.; Mensah, S.Y.; Brown, C.S.

    2001-04-01

    The nonlinear polarization effects in a birefringent single mode optical fiber is studied using Jacobi elliptic functions. We find that the polarization state of the propagating beam depends on the initial polarization as well as the intensity of the input light in a complicated way. The Stokes polarization parameters are either periodic or aperiodic depending on the value of the Jacobian modulus. Our calculations suggest that the effective beat length of the fiber can become infinite at a higher critical value of the input power when polarization dependent losses are considered. (author)

  2. [Value of sepsis single-disease manage system in predicting mortality in patients with sepsis].

    Science.gov (United States)

    Chen, J; Wang, L H; Ouyang, B; Chen, M Y; Wu, J F; Liu, Y J; Liu, Z M; Guan, X D

    2018-04-03

    Objective: To observe the effect of sepsis single-disease manage system on the improvement of sepsis treatment and the value in predicting mortality in patients with sepsis. Methods: A retrospective study was conducted. Patients with sepsis admitted to the Department of Surgical Intensive Care Unit of Sun Yat-Sen University First Affiliated Hospital from September 22, 2013 to May 5, 2015 were enrolled in this study. Sepsis single-disease manage system (Rui Xin clinical data manage system, China data, China) was used to monitor 25 clinical quality parameters, consisting of timeliness, normalization and outcome parameters. Based on whether these quality parameters could be completed or not, the clinical practice was evaluated by the system. The unachieved quality parameter was defined as suspicious parameters, and these suspicious parameters were used to predict mortality of patients with receiver operating characteristic curve (ROC). Results: A total of 1 220 patients with sepsis were enrolled, included 805 males and 415 females. The mean age was (59±17) years, and acute physiology and chronic health evaluation (APACHE Ⅱ) scores was 19±8. The area under ROC curve of total suspicious numbers for predicting 28-day mortality was 0.70; when the suspicious parameters number was more than 6, the sensitivity was 68.0% and the specificity was 61.0% for predicting 28-day mortality. In addition, the area under ROC curve of outcome suspicious number for predicting 28-day mortality was 0.89; when the suspicious outcome parameters numbers was more than 1, the sensitivity was 88.0% and the specificity was 78.0% for predicting 28-day mortality. Moreover, the area under ROC curve of total suspicious number for predicting 90-day mortality was 0.73; when the total suspicious parameters number was more than 7, the sensitivity was 60.0% and the specificity was 74.0% for predicting 90-day mortality. Finally, the area under ROC curve of outcome suspicious numbers for predicting 90

  3. Prognostic value of worsening renal function in outpatients with chronic heart failure.

    Science.gov (United States)

    Pimentel, Rodrigo; Couto, Marta; Laszczyńska, Olga; Friões, Fernando; Bettencourt, Paulo; Azevedo, Ana

    2014-09-01

    Renal function impairment predicts poor survival in heart failure. Attention has recently shifted to worsening renal function, based mostly on serum creatinine and estimated glomerular filtration rate. We assessed the prognostic effect of worsening renal function in ambulatory heart failure patients. Data from 306 ambulatory patients were abstracted from medical files. Worsening renal function was based on the change in estimated glomerular filtration rate, serum creatinine and urea within 6 months of referral. Prognosis was assessed by the composite endpoint all-cause death or heart failure hospitalization, censored at 2 years. Hazard ratios were estimated for worsening renal function, adjusted for sex, age, diabetes, New York Heart Association class, left ventricular systolic dysfunction, medications and baseline renal function. The agreement among definitions was fair, with kappa coefficients generally not surpassing 0.5. Worsening renal function was associated with poor outcome with adjusted hazard ratios (95% confidence interval) of 3.2 (1.8-5.9) for an increase of serum creatinine >0.3mg/dl; 2.2 (1.3-3.7) for an increase in serum urea >20mg/dl and 1.9 (1.1-3.3) for a decrease in estimated glomerular filtration rate >20%, independent of baseline renal function. The 2-year risk of death/heart failure hospitalization was approximately 50% in patients with an increase in serum creatinine or in serum urea; this positive predictive value was higher than for decreasing estimated glomerular filtration rate. In conclusion, worsening renal function was significantly associated with a worse outcome. Different definitions identified different patients at risk and increasing creatinine/urea performed better than decreasing estimated glomerular filtration rate. Copyright © 2014 European Federation of Internal Medicine. Published by Elsevier B.V. All rights reserved.

  4. Molecular level computational studies of polyethylene and polyacrylonitrile composites containing single walled carbon nanotubes: effect of carboxylic acid functionalization on nanotube-polymer interfacial properties

    Directory of Open Access Journals (Sweden)

    Shayesteh eHaghighatpanah

    2014-09-01

    Full Text Available Molecular dynamics and molecular mechanics methods have been used to investigate additive-polymer interfacial properties in single walled carbon nanotube – polyethylene and single walled carbon nanotube – polyacrylonitrile composites. Properties such as the interfacial shear stress and bonding energy are similar for the two composites. In contrast, functionalizing the single walled carbon nanotubes with carboxylic acid groups leads to an increase in these properties, with a larger increase for the polar polyacrylonitrile composite. Increasing the percentage of carbon atoms that were functionalized from 1% to 5% also leads to an increase in the interfacial properties. In addition, the interfacial properties depend on the location of the functional groups on the single walled carbon nanotube wall.

  5. Selective detection of SO2 at room temperature based on organoplatinum functionalized single-walled carbon nanotube field effect transistors

    NARCIS (Netherlands)

    Cid, C.C.; Jimenez-Cadena, G.; Riu, J.; Maroto, A.; Rius, F.X.; Batema, G.D.; van Koten, G.

    2009-01-01

    We report a field effect transistor (FET) based on a network of single-walled carbon nanotubes (SWCNTs) that for the first time can selectively detect a single gaseous molecule in air by chemically functionalizing the SWCNTs with a selective molecular receptor. As a target model we used SO2. The

  6. Weak value controversy

    Science.gov (United States)

    Vaidman, L.

    2017-10-01

    Recent controversy regarding the meaning and usefulness of weak values is reviewed. It is argued that in spite of recent statistical arguments by Ferrie and Combes, experiments with anomalous weak values provide useful amplification techniques for precision measurements of small effects in many realistic situations. The statistical nature of weak values is questioned. Although measuring weak values requires an ensemble, it is argued that the weak value, similarly to an eigenvalue, is a property of a single pre- and post-selected quantum system. This article is part of the themed issue `Second quantum revolution: foundational questions'.

  7. Experimental and density functional theory (DFT): A dual approach to probe the key properties of creatininium L-tartrate monohydrate single crystal for nonlinear optical applications

    Science.gov (United States)

    Thirumurugan, R.; Babu, B.; Anitha, K.; Chandrasekaran, J.

    2017-12-01

    A novel organic nonlinear optical (NLO) material, creatininium L-tartrate monohydrate (CTM) was synthesized and it was grown as single crystals with optical quality. 1H and 13C NMR spectral studies were performed and molecular structure of synthesized CTM compound was confirmed. Single crystal X-ray diffraction (SXRD) analysis confirmed that CTM was crystallized in orthorhombic system with non-centrosymmetric (NCS), P212121, space group. The grown crystal exhibited admirable properties such as second harmonic generation efficiency (SHG) (1.9 times KDP), and high laser damage threshold (LDT) value of 3.7 GW cm-2. CTM crystal displayed high transparency (∼60%) in the visible and near-IR region with low cut-off wavelength at 249 nm. Photoluminescence study confirmed blue wavelength emission (∼463 nm) of grown crystal. Thermal and mechanical behaviours have been successfully analysed for grown crystals. The dielectric studies were carried out for grown crystal as a function of frequencies at different temperatures. Hirshfeld surface and fingerprint plots provided the percentage of individual interactions contributed by each atom. Moreover, density functional theory (DFT) calculations have been employed to probe the frontier molecular orbitals (FMOs) and first hyperpolarizability (β) analysis of the optimized CTM structure. These results validated CTM as a suitable NLO candidate and were discussed in this work.

  8. Benchmark study of ionization potentials and electron affinities of armchair single-walled carbon nanotubes using density functional theory

    Science.gov (United States)

    Zhou, Bin; Hu, Zhubin; Jiang, Yanrong; He, Xiao; Sun, Zhenrong; Sun, Haitao

    2018-05-01

    The intrinsic parameters of carbon nanotubes (CNTs) such as ionization potential (IP) and electron affinity (EA) are closely related to their unique properties and associated applications. In this work, we demonstrated the success of optimal tuning method based on range-separated (RS) density functionals for both accurate and efficient prediction of vertical IPs and electron affinities (EAs) of a series of armchair single-walled carbon nanotubes C20n H20 (n  =  2–6) compared to the high-level IP/EA equation-of-motion coupled-cluster method with single and double substitutions (IP/EA-EOM-CCSD). Notably, the resulting frontier orbital energies (–ε HOMO and –ε LUMO) from the tuning method exhibit an excellent approximation to the corresponding IPs and EAs, that significantly outperform other conventional density functionals. In addition, it is suggested that the RS density functionals that possess both a fixed amount of exact exchange in the short-range and a correct long-range asymptotic behavior are suitable for calculating electronic structures of finite-sized CNTs. Next the performance of density functionals for description of various molecular properties such as chemical potential, hardness and electrophilicity are assessed as a function of tube length. Thanks to the efficiency and accuracy of this tuning method, the related behaviors of much longer armchair single-walled CNTs until C200H20 were studied. Lastly, the present work is proved to provide an efficient theoretical tool for future materials design and reliable characterization of other interesting properties of CNT-based systems.

  9. From free energy to expected energy: Improving energy-based value function approximation in reinforcement learning.

    Science.gov (United States)

    Elfwing, Stefan; Uchibe, Eiji; Doya, Kenji

    2016-12-01

    Free-energy based reinforcement learning (FERL) was proposed for learning in high-dimensional state and action spaces. However, the FERL method does only really work well with binary, or close to binary, state input, where the number of active states is fewer than the number of non-active states. In the FERL method, the value function is approximated by the negative free energy of a restricted Boltzmann machine (RBM). In our earlier study, we demonstrated that the performance and the robustness of the FERL method can be improved by scaling the free energy by a constant that is related to the size of network. In this study, we propose that RBM function approximation can be further improved by approximating the value function by the negative expected energy (EERL), instead of the negative free energy, as well as being able to handle continuous state input. We validate our proposed method by demonstrating that EERL: (1) outperforms FERL, as well as standard neural network and linear function approximation, for three versions of a gridworld task with high-dimensional image state input; (2) achieves new state-of-the-art results in stochastic SZ-Tetris in both model-free and model-based learning settings; and (3) significantly outperforms FERL and standard neural network function approximation for a robot navigation task with raw and noisy RGB images as state input and a large number of actions. Copyright © 2016 The Author(s). Published by Elsevier Ltd.. All rights reserved.

  10. Locally Sensitive Lattice-Valued Possibilistic Entropy Functions

    Czech Academy of Sciences Publication Activity Database

    Kramosil, Ivan

    2008-01-01

    Roč. 18, č. 6 (2008), s. 469-488 ISSN 1210-0552 R&D Projects: GA AV ČR IAA100300503 Institutional research plan: CEZ:AV0Z10300504 Keywords : complete lattice * chained lattice * lattice-valued possibilistic distribution * possibilistic expected value Subject RIV: BA - General Mathematics Impact factor: 0.395, year: 2008

  11. Parental Autonomy Granting and School Functioning among Chinese Adolescents: The Moderating Role of Adolescents' Cultural Values.

    Science.gov (United States)

    Wang, Cixin; Do, Kieu Anh; Bao, Leiping; Xia, Yan R; Wu, Chaorong

    2017-01-01

    School adjustment and achievement are important indicators of adolescents' well-being; however, few studies have examined the risk and protective factors predicting students' school adjustment and achievement at the individual, familial, and cultural level. The present study examined the influences of individual and familial factors and cultural values on Chinese adolescents' school functioning (e.g., school adjustment and grades). It also tested whether cultural values moderated the relationship between parenting and adolescents' school functioning. Self-report data were collected from a stratified random sample of 2,864 adolescents (51.5% female, mean age = 15.52 years, grade 6th - 12th) from 55 classrooms, in 13 schools in Shanghai, China. Results showed that self-esteem ( b se→adj = 0.05, SE = 0.01, p school adjustment and grades, respectively. More importantly, results showed that independent self-construal moderated the relationship between parental autonomy granting and adolescents' grades ( b indepxautom = 0.06, SE = 0.02, p autonomy granting, which then impacts their school functioning.

  12. Common fixed points of single-valued and multivalued maps

    Directory of Open Access Journals (Sweden)

    Yicheng Liu

    2005-01-01

    Full Text Available We define a new property which contains the property (EA for a hybrid pair of single- and multivalued maps and give some new common fixed point theorems under hybrid contractive conditions. Our results extend previous ones. As an application, we give a partial answer to the problem raised by Singh and Mishra.

  13. Operational production of Geodetic Excitation Functions from EOP estimated values at ASI-CGS

    Science.gov (United States)

    Sciarretta, C.; Luceri, V.; Bianco, G.

    2009-04-01

    ASI-CGS is routinely providing geodetic excitation functions from its own estimated EOP values (at present SLR and VLBI; the current use of GPS EOP's is also planned as soon as this product will be fully operational) on the ASI geodetic web site (http://geodaf.mt.asi.it). This product has been generated and monitored (for ASI internal use only) in a long pre-operational phase (more than two years), including validation and testing. The daily geodetic excitation functions are now weekly updated along with the operational ASI SLR and VLBI EOP solutions and compared, whenever possible, with the atmospheric excitation functions available at the IERS SBAAM, under the IB and not-IB assumption, including the "wind" term. The work will present the available estimated geodetic function time series and its comparison with the relevant atmospheric excitation functions, deriving quantitative indicators on the quality of the estimates. The similarities as well as the discrepancies among the atmospheric and geodetic series will be analysed and commented, evaluating in particular the degree of correlation among the two estimated time series and the likelihood of a linear dependence hypothesis.

  14. Functional topography of single cortical cells: an intracellular approach combined with optical imaging.

    Science.gov (United States)

    Buzás, P; Eysel, U T; Kisvárday, Z F

    1998-11-01

    Pyramidal cells mediating long-range corticocortical connections have been assumed to play an important role in visual perceptual mechanisms [C.D. Gilbert, Horizontal integration and cortical dynamics, Neuron 9 (1992) 1-13]. However, no information is available as yet on the specificity of individual pyramidal cells with respect to functional maps, e.g., orientation map. Here, we show a combination of techniques with which the functional topography of single pyramidal neurons can be explored in utmost detail. To this end, we used optical imaging of intrinsic signals followed by intracellular recording and staining with biocytin in vivo. The axonal and dendritic trees of the labelled neurons were reconstructed in three dimensions and aligned with corresponding functional orientation maps. The results indicate that, contrary to the sharp orientation tuning of neurons shown by the recorded spike activity, the efferent connections (axon terminal distribution) of the same pyramidal cells were found to terminate at a much broader range of orientations. Copyright 1998 Elsevier Science B.V.

  15. The role of singular values of measured frequency response function matrix in modal damping estimation (Part I: Theory)

    OpenAIRE

    Pápai, Ferenc; Szűcs, István

    2015-01-01

    The singular value decomposition of the measured frequency response function matrix, as a very effective tool of experimental modal analysis is used over the last twenty-five years. The complex mode indication function has become a common numerical tool in processing experimental data. There are many references on the development of complex mode indication function including the enhanced mode indication function and its use together with the enhanced frequency response function to form spatia...

  16. The role of singular values of measured frequency response function matrix in modal damping estimation (Part II: Investigations)

    OpenAIRE

    Pápai, Ferenc; Szűcs, István

    2015-01-01

    The singular value decomposition of the measured frequency response function matrix, as a very effective tool of experimental modal analysis is used over the last twenty-five years. The complex mode indication function has become a common numerical tool in processing experimental data. There are many references on the development of complex mode indication function including the enhanced mode indication function and its use together with the enhanced frequency response function to form spatia...

  17. A Conjugate Gradient Algorithm with Function Value Information and N-Step Quadratic Convergence for Unconstrained Optimization.

    Directory of Open Access Journals (Sweden)

    Xiangrong Li

    Full Text Available It is generally acknowledged that the conjugate gradient (CG method achieves global convergence--with at most a linear convergence rate--because CG formulas are generated by linear approximations of the objective functions. The quadratically convergent results are very limited. We introduce a new PRP method in which the restart strategy is also used. Moreover, the method we developed includes not only n-step quadratic convergence but also both the function value information and gradient value information. In this paper, we will show that the new PRP method (with either the Armijo line search or the Wolfe line search is both linearly and quadratically convergent. The numerical experiments demonstrate that the new PRP algorithm is competitive with the normal CG method.

  18. A Conjugate Gradient Algorithm with Function Value Information and N-Step Quadratic Convergence for Unconstrained Optimization.

    Science.gov (United States)

    Li, Xiangrong; Zhao, Xupei; Duan, Xiabin; Wang, Xiaoliang

    2015-01-01

    It is generally acknowledged that the conjugate gradient (CG) method achieves global convergence--with at most a linear convergence rate--because CG formulas are generated by linear approximations of the objective functions. The quadratically convergent results are very limited. We introduce a new PRP method in which the restart strategy is also used. Moreover, the method we developed includes not only n-step quadratic convergence but also both the function value information and gradient value information. In this paper, we will show that the new PRP method (with either the Armijo line search or the Wolfe line search) is both linearly and quadratically convergent. The numerical experiments demonstrate that the new PRP algorithm is competitive with the normal CG method.

  19. A test of the reward-value hypothesis.

    Science.gov (United States)

    Smith, Alexandra E; Dalecki, Stefan J; Crystal, Jonathon D

    2017-03-01

    Rats retain source memory (memory for the origin of information) over a retention interval of at least 1 week, whereas their spatial working memory (radial maze locations) decays within approximately 1 day. We have argued that different forgetting functions dissociate memory systems. However, the two tasks, in our previous work, used different reward values. The source memory task used multiple pellets of a preferred food flavor (chocolate), whereas the spatial working memory task provided access to a single pellet of standard chow-flavored food at each location. Thus, according to the reward-value hypothesis, enhanced performance in the source memory task stems from enhanced encoding/memory of a preferred reward. We tested the reward-value hypothesis by using a standard 8-arm radial maze task to compare spatial working memory accuracy of rats rewarded with either multiple chocolate or chow pellets at each location using a between-subjects design. The reward-value hypothesis predicts superior accuracy for high-valued rewards. We documented equivalent spatial memory accuracy for high- and low-value rewards. Importantly, a 24-h retention interval produced equivalent spatial working memory accuracy for both flavors. These data are inconsistent with the reward-value hypothesis and suggest that reward value does not explain our earlier findings that source memory survives unusually long retention intervals.

  20. Single image super-resolution based on approximated Heaviside functions and iterative refinement

    Science.gov (United States)

    Wang, Xin-Yu; Huang, Ting-Zhu; Deng, Liang-Jian

    2018-01-01

    One method of solving the single-image super-resolution problem is to use Heaviside functions. This has been done previously by making a binary classification of image components as “smooth” and “non-smooth”, describing these with approximated Heaviside functions (AHFs), and iteration including l1 regularization. We now introduce a new method in which the binary classification of image components is extended to different degrees of smoothness and non-smoothness, these components being represented by various classes of AHFs. Taking into account the sparsity of the non-smooth components, their coefficients are l1 regularized. In addition, to pick up more image details, the new method uses an iterative refinement for the residuals between the original low-resolution input and the downsampled resulting image. Experimental results showed that the new method is superior to the original AHF method and to four other published methods. PMID:29329298

  1. Functional and cosmetic outcome of single-digit ray amputation in hand.

    Science.gov (United States)

    Bhat, A K; Acharya, A M; Narayanakurup, J K; Kumar, B; Nagpal, P S; Kamath, A

    2017-12-01

    To assess patient satisfaction, functional and cosmetic outcomes of single-digit ray amputation in hand and identify factors that might affect the outcome. Forty-five patients who underwent ray amputation were evaluated, 37 males and eight females whose mean age was 36.6 years ranging between 15 and 67 years. Twenty-eight patients had dominant hand involvement. Twenty-one patients underwent primary ray amputation, and 24 patients had secondary ray amputation. Eight out of the 23 patients with central digit injuries underwent transposition. Grip strength, pinch strength, tactile sensibility and functional evaluation using Result Assessment Scale (RAS) and DASH score were analysed. Cosmetic assessment was performed using visual analogue scale (VAS) for cosmesis. Median time of assessment after surgery was 20 months. Average loss of grip strength and pinch strength was found to be 43.3 and 33.6%, respectively. Average RAS score was 3.75. Median DASH score was 23.4. Eighty-three percentage of patients had excellent or good cosmesis on the VAS. Transposition causes significant increase in DASH scores for central digit ray amputations but was cosmetically superior. Middle finger ray amputation had the maximum loss of grip strength, and index finger ray amputation had greater loss of pinch strength. Affection of neighbouring digits caused greater grip and pinch loss, and a higher DASH score. Primary ray resection decreased the total disability and eliminated the costs of a second procedure. Following ray amputation, one can predict an approximate 43.3% loss of grip strength and 33.6% loss of pinch strength. The patients can be counselled regarding the expected time off from work, amount of disability and complications after a single-digit ray amputation. Majority of the patients can return to the same occupation after a period of dedicated hand therapy. Therapeutic, Level III.

  2. [Diagnostic value and functional correlations of the ADAS-Cog scale in Alzheimer's disease: data on NORMACODEM project].

    Science.gov (United States)

    Monllau, A; Pena-Casanova, J; Blesa, R; Aguilar, M; Bohm, P; Sol, J M; Hernandez, G

    2007-10-01

    The aims of this study were to assess the criterion validity of Alzheimer's Disease Assessment Scale (ADAS) and its cognitive subscale (ADAS-Cog) for the diagnosis of Alzheimer's disease (AD), and to determine their different cut-off scores and sensitivity and specificity values. In addition, we also attempted to study the possible correlations between cognitive scores (ADAS) and functional measures. 451 subjects were studied (254 controls, 86 subjects with mild cognitive impairment and 111 patients with AD). ADAS total score was obtained by adding the cognitive (ADAS-Cog) and non-cognitive (ADAS-Nocog) scales. Scores were adjusted for age and formal education. For assessing the possible correlation between cognitive and functional measures, the following instruments were administered: Rapid Disability Rating Scale-2 (RDRS-2), Blessed Dementia Rating Scale (BDRS) and the Interview for the Deterioration of Daily Living in Dementia (IDDD). ROC curves and Pearson correlation coefficient. ADAS best cut-off score for dementia was > or = 17 providing sensitivity and specificity values of 90.09% and 85.88 % respectively, while for the ADAS-Cog best cut-off score was > or = 12 with sensitivity and specificity values of 89.19 % and 88.53 % respectively. In both cases scores were adjusted for age and formal education. The area under the ROC curve was 0.95 and 0.94 respectively. Highly significant correlations were found for ADAS and 19 ADAS-Cog with the functional scales studied. Both, ADAS and ADAS-Cog report good validity in terms of sensitivity, specificity and as predictive value for AD. Moreover, significant correlations were found between the functional impairment observed in patients with AD and the overall scores achieved in the ADAS and ADAS-Cog.

  3. Difference in long-term prognostic value of renal function between ischemic and non-ischemic mild heart failure

    NARCIS (Netherlands)

    Smilde, TDJ; Hillege, HL; Navis, G; Voors, AA; Brouwer, J; van Veldhuisen, DJ

    2006-01-01

    Introduction: Renal function is one of the strongest prognostic markers in patients with chronic heart failure, but it has been suggested that this might be due to (local, i.e. renal) vascular atherosclerosis. The aim of the present study is to evaluate the prognostic value of renal function in both

  4. Measurement system of correlation functions of microwave single photon source in real time

    Science.gov (United States)

    Korenkov, A.; Dmitriev, A.; Astafiev, O.

    2018-02-01

    Several quantum setups, such as quantum key distribution networks[1] and quantum simulators (e.g. boson sampling), by their design rely on single photon sources (SPSs). These quantum setups were demonstrated to operate in optical frequency domain. However, following the steady advances in circuit quantum electrodynamics, a proposal has been made recently[2] to demonstrate boson sampling with microwave photons. This in turn requires the development of reliable microwave SPS. It's one of the most important characteristics are the first-order and the second-order correlation functions g1 and g2. The measurement technique of g1 and g2 is significantly different from that in the optical domain [3],[4] because of the current unavailability of microwave single-photon detectors. In particular, due to high levels of noise present in the system a substantial amount of statistics in needed to be acquired. This work presents a platform for measurement of g1 and g2 that processes the incoming data in real time, maximizing the efficiency of data acquisition. The use of field-programmable gate array (FPGA) electronics, common in similar experiments[3] but complex in programming, is avoided; instead, the calculations are performed on a standard desktop computer. The platform is used to perform the measurements of the first-order and the second-order correlation functions of the microwave SPS.

  5. Dimensional feature weighting utilizing multiple kernel learning for single-channel talker location discrimination using the acoustic transfer function.

    Science.gov (United States)

    Takashima, Ryoichi; Takiguchi, Tetsuya; Ariki, Yasuo

    2013-02-01

    This paper presents a method for discriminating the location of the sound source (talker) using only a single microphone. In a previous work, the single-channel approach for discriminating the location of the sound source was discussed, where the acoustic transfer function from a user's position is estimated by using a hidden Markov model of clean speech in the cepstral domain. In this paper, each cepstral dimension of the acoustic transfer function is newly weighted, in order to obtain the cepstral dimensions having information that is useful for classifying the user's position. Then, this paper proposes a feature-weighting method for the cepstral parameter using multiple kernel learning, defining the base kernels for each cepstral dimension of the acoustic transfer function. The user's position is trained and classified by support vector machine. The effectiveness of this method has been confirmed by sound source (talker) localization experiments performed in different room environments.

  6. The focal boundary value problem for strongly singular higher-order nonlinear functional-differential equations

    Czech Academy of Sciences Publication Activity Database

    Mukhigulashvili, Sulkhan; Půža, B.

    2015-01-01

    Roč. 2015, January (2015), s. 17 ISSN 1687-2770 Institutional support: RVO:67985840 Keywords : higher order nonlinear functional-differential equations * two-point right-focal boundary value problem * strong singularity Subject RIV: BA - General Mathematics Impact factor: 0.642, year: 2015 http://link.springer.com/article/10.1186%2Fs13661-014-0277-1

  7. Value of preoperative esophageal function studies before laparoscopic antireflux surgery.

    Science.gov (United States)

    Chan, Walter W; Haroian, Laura R; Gyawali, C Prakash

    2011-09-01

    The value of esophageal manometry and ambulatory pH monitoring before laparoscopic antireflux surgery (LARS) has been questioned because tailoring the operation to the degree of hypomotility often is not required. This study evaluated a consecutive cohort of patients referred for esophageal function studies in preparation for LARS to determine the rates of findings that would alter surgical decisions. High-resolution manometry (HRM) was performed for each subject using a 21-lumen water-perfused system, and motor function was characterized. Gastroesophageal reflux disease (GERD) was evident from ambulatory pH monitoring if thresholds for acid exposure time and/or positive symptom association probability were passed. Of 1,081 subjects (age, 48.4 ± 0.4 years; 56.7% female) undergoing preoperative HRM, 723 (66.9%) also had ambulatory pH testing performed. Lower esophageal sphincter (LES) hypotension (38.9%) and nonspecific spastic disorder (NSSD) of the esophageal body (36.1%) were common. Obstructive LES pathophysiology was noted in 2.5% (achalasia in 1%; incomplete LES relaxation in 1.5%), and significant esophageal body hypomotility in 4.5% (aperistalsis in 3.2%; severe hypomotility in 1.3%) of the subjects. Evidence of GERD was absent in 23.9% of the subjects. Spastic disorders were more frequent in the absence of GERD (43.9% vs. 23.1% with GERD; p esophageal function testing that could be used in preoperative counseling and candidate selection. Physiologic testing remains important in the preoperative evaluation of patients being considered for LARS.

  8. The social value of mortality risk reduction: VSL versus the social welfare function approach.

    Science.gov (United States)

    Adler, Matthew D; Hammitt, James K; Treich, Nicolas

    2014-05-01

    We examine how different welfarist frameworks evaluate the social value of mortality risk reduction. These frameworks include classical, distributively unweighted cost-benefit analysis--i.e., the "value per statistical life" (VSL) approach-and various social welfare functions (SWFs). The SWFs are either utilitarian or prioritarian, applied to policy choice under risk in either an "ex post" or "ex ante" manner. We examine the conditions on individual utility and on the SWF under which these frameworks display sensitivity to wealth and to baseline risk. Moreover, we discuss whether these frameworks satisfy related properties that have received some attention in the literature, namely equal value of risk reduction, preference for risk equity, and catastrophe aversion. We show that the particular manner in which VSL ranks risk-reduction measures is not necessarily shared by other welfarist frameworks. Copyright © 2014 Elsevier B.V. All rights reserved.

  9. LINTAB, Linear Interpolable Tables from any Continuous Variable Function

    International Nuclear Information System (INIS)

    1988-01-01

    1 - Description of program or function: LINTAB is designed to construct linearly interpolable tables from any function. The program will start from any function of a single continuous variable... FUNKY(X). By user input the function can be defined, (1) Over 1 to 100 X ranges. (2) Within each X range the function is defined by 0 to 50 constants. (3) At boundaries between X ranges the function may be continuous or discontinuous (depending on the constants used to define the function within each X range). 2 - Method of solution: LINTAB will construct a table of X and Y values where the tabulated (X,Y) pairs will be exactly equal to the function (Y=FUNKY(X)) and linear interpolation between the tabulated pairs will be within any user specified fractional uncertainty of the function for all values of X within the requested X range

  10. The diagnostic value of single-photon emission computed tomography/computed tomography for severe sacroiliac joint dysfunction.

    Science.gov (United States)

    Tofuku, Katsuhiro; Koga, Hiroaki; Komiya, Setsuro

    2015-04-01

    We aimed to evaluate the value of single-photon emission computed tomography (SPECT)/computed tomography (CT) for the diagnosis of sacroiliac joint (SIJ) dysfunction. SPECT/CT was performed in 32 patients with severe SIJ dysfunction, who did not respond to 1-year conservative treatment and had a score of >4 points on a 10-cm visual analog scale. We investigated the relationship between the presence of severe SIJ dysfunction and tracer accumulation, as confirmed by SPECT/CT. In cases of bilateral SIJ dysfunction, we also compared the intensity of tracer accumulation on each side. Moreover, we examined the relationship between the intensity of tracer accumulation and the different treatments the patients subsequently received. All 32 patients with severe SIJ dysfunction had tracer accumulation with a standardized uptake value (SUV) of >2.2 (mean SUV 4.7). In the 19 patients with lateralized symptom intensity, mean SUVs of the dominant side were significantly higher than those of the nondominant side. In 10 patients with no lateralization, the difference in the SUVs between sides was dysfunction as well as a useful technique for predicting the prognosis of this condition.

  11. Single-site Green function of the Dirac equation for full-potential electron scattering

    Energy Technology Data Exchange (ETDEWEB)

    Kordt, Pascal

    2012-05-30

    I present an elaborated analytical examination of the Green function of an electron scattered at a single-site potential, for both the Schroedinger and the Dirac equation, followed by an efficient numerical solution, in both cases for potentials of arbitrary shape without an atomic sphere approximation. A numerically stable way to calculate the corresponding regular and irregular wave functions and the Green function is via the angular Lippmann-Schwinger integral equations. These are solved based on an expansion in Chebyshev polynomials and their recursion relations, allowing to rewrite the Lippmann-Schwinger equations into a system of algebraic linear equations. Gonzales et al. developed this method for the Schroedinger equation, where it gives a much higher accuracy compared to previous perturbation methods, with only modest increase in computational effort. In order to apply it to the Dirac equation, I developed relativistic Lippmann-Schwinger equations, based on a decomposition of the potential matrix into spin spherical harmonics, exploiting certain properties of this matrix. The resulting method was embedded into a Korringa-Kohn-Rostoker code for density functional calculations. As an example, the method is applied by calculating phase shifts and the Mott scattering of a tungsten impurity. (orig.)

  12. Single-site Green function of the Dirac equation for full-potential electron scattering

    International Nuclear Information System (INIS)

    Kordt, Pascal

    2012-01-01

    I present an elaborated analytical examination of the Green function of an electron scattered at a single-site potential, for both the Schroedinger and the Dirac equation, followed by an efficient numerical solution, in both cases for potentials of arbitrary shape without an atomic sphere approximation. A numerically stable way to calculate the corresponding regular and irregular wave functions and the Green function is via the angular Lippmann-Schwinger integral equations. These are solved based on an expansion in Chebyshev polynomials and their recursion relations, allowing to rewrite the Lippmann-Schwinger equations into a system of algebraic linear equations. Gonzales et al. developed this method for the Schroedinger equation, where it gives a much higher accuracy compared to previous perturbation methods, with only modest increase in computational effort. In order to apply it to the Dirac equation, I developed relativistic Lippmann-Schwinger equations, based on a decomposition of the potential matrix into spin spherical harmonics, exploiting certain properties of this matrix. The resulting method was embedded into a Korringa-Kohn-Rostoker code for density functional calculations. As an example, the method is applied by calculating phase shifts and the Mott scattering of a tungsten impurity. (orig.)

  13. Single photon emission tomography

    International Nuclear Information System (INIS)

    Buvat, Irene

    2011-09-01

    The objective of this lecture is to present the single photon emission computed tomography (SPECT) imaging technique. Content: 1 - Introduction: anatomic, functional and molecular imaging; Principle and role of functional or molecular imaging; 2 - Radiotracers: chemical and physical constraints, main emitters, radioisotopes production, emitters type and imaging techniques; 3 - Single photon emission computed tomography: gamma cameras and their components, gamma camera specifications, planar single photon imaging characteristics, gamma camera and tomography; 4 - Quantification in single photon emission tomography: attenuation, scattering, un-stationary spatial resolution, partial volume effect, movements, others; 5 - Synthesis and conclusion

  14. Neutron transmission of single-crystal sapphire filters

    International Nuclear Information System (INIS)

    Adib, M.; Kilany, M.; Habib, N.; Fathallah, M.

    2004-01-01

    A simple additive formula is given that permits the calculation of the nuclear capture, thermal diffuse and Bragg scattering cross-sections as a function of sapphire temperature and crystal parameters. We have developed a computer program that allows calculations of the thermal neutron transmission for the sapphire rhombohedral structure and its equivalent trigonal structure. The calculated total cross-section values and effective attenuation coefficient for mono-crystalline sapphire at different temperatures are compared with measured values. Overall agreement is indicated between the formula fits and experimental data. We discuss the use of sapphire single-crystal as a thermal neutron filter in terms of the optimum crystal thickness, mosaic spread, temperature, cutting plane and tuning for efficient transmission of thermal-reactor neutrons

  15. Species contributions to single biodiversity values under-estimate whole community contribution to a wider range of values to society.

    Science.gov (United States)

    Hiron, Matthew; Pärt, Tomas; Siriwardena, Gavin M; Whittingham, Mark J

    2018-05-03

    A major task for decision makers is deciding how to consider monetary, cultural and conservation values of biodiversity explicitly when planning sustainable land use. Thus, there is a great need to understand just what "valuing" biodiversity or species really means, e.g. regarding how many and which species are important in providing ecosystem services or other values. Constructing ecosystem-level indices, however, requires weighting the relative contribution of species to the different values. Using farmland birds, we illustrate how species contribute to different biodiversity values, namely utilitarian (pest seed predation potential), cultural (species occurrence in poetry), conservational (declines and rarity) and inherent (all species equal) value. Major contributions to each value are often made by a subset of the community and different species are important for different values, leading to no correlations or, in some cases, negative correlations between species' relative contributions to different values. Our results and methods using relative contributions of species to biodiversity values can aid decisions when weighing different values in policies and strategies for natural resource management. We conclude that acknowledging the importance of the range of biodiversity values that are apparent from different perspectives is critical if the full value of biodiversity to society is to be realised.

  16. Customer Focused Product Design Using Integrated Model of Target Costing, Quality Function Deployment and Value Engineering

    Directory of Open Access Journals (Sweden)

    Hossein Rezaei Dolatabadi

    2013-01-01

    Full Text Available Target costing by integrating customer requirements, technical attributes and cost information into the product design phase and eliminating the non-value added functions, plays a vital role in different phases of the product life cycle. Quality Function Deployment (QFD and Value Engineering (VE are two techniques which can be used for applying target costing, successfully. The purpose of this paper is to propose an integrated model of target costing, QFD and VE to explore the role of target costing in managing product costs while promoting quality specifications meeting customers’ needs. F indings indicate that the integration of target costing, QFD and VE is an essential technique in managing the costs of production process. Findings also imply that integration of the three techniques provides a competitive cost advantage to companies.

  17. Clinical value of CT-based preoperative software assisted lung lobe volumetry for predicting postoperative pulmonary function after lung surgery

    Science.gov (United States)

    Wormanns, Dag; Beyer, Florian; Hoffknecht, Petra; Dicken, Volker; Kuhnigk, Jan-Martin; Lange, Tobias; Thomas, Michael; Heindel, Walter

    2005-04-01

    This study was aimed to evaluate a morphology-based approach for prediction of postoperative forced expiratory volume in one second (FEV1) after lung resection from preoperative CT scans. Fifteen Patients with surgically treated (lobectomy or pneumonectomy) bronchogenic carcinoma were enrolled in the study. A preoperative chest CT and pulmonary function tests before and after surgery were performed. CT scans were analyzed by prototype software: automated segmentation and volumetry of lung lobes was performed with minimal user interaction. Determined volumes of different lung lobes were used to predict postoperative FEV1 as percentage of the preoperative values. Predicted FEV1 values were compared to the observed postoperative values as standard of reference. Patients underwent lobectomy in twelve cases (6 upper lobes; 1 middle lobe; 5 lower lobes; 6 right side; 6 left side) and pneumonectomy in three cases. Automated calculation of predicted postoperative lung function was successful in all cases. Predicted FEV1 ranged from 54% to 95% (mean 75% +/- 11%) of the preoperative values. Two cases with obviously erroneous LFT were excluded from analysis. Mean error of predicted FEV1 was 20 +/- 160 ml, indicating absence of systematic error; mean absolute error was 7.4 +/- 3.3% respective 137 +/- 77 ml/s. The 200 ml reproducibility criterion for FEV1 was met in 11 of 13 cases (85%). In conclusion, software-assisted prediction of postoperative lung function yielded a clinically acceptable agreement with the observed postoperative values. This method might add useful information for evaluation of functional operability of patients with lung cancer.

  18. Myocardial sestamibi single-photon emission tomography: variations in reference values with gender, age and rest versus stress?

    International Nuclear Information System (INIS)

    Toft, J.; Hesse, B.; Raboel, A.; Carstensen, S.; Ali, S.

    1997-01-01

    Reference data files support the evaluation of myocardial perfusion single-photon emission tomography (SPET). The aim of this study was to create a large reference data base for technetium-99m sestamibi SPET, age and gender matched to the general patient population. One hundred and twenty-eight healthy volunteers (76 males and 52 females) with a likelihood of coronary artery disease of less than 5% underwent rest and maximal exercise 99m Tc-sestamibi SPET with a 2-day protocol and 180 elliptical rotation. The normalized activity values of 99m Tc-sestamibi in the inferior wall differed significantly between men and women. Age variations were found for men in the anterior wall. Normalized activity values in all four walls were strikingly similar during rest and stress. Our results suggest that the use of reference files in 99m Tc-sestamibi SPET requires a gender- and, for males, possibly an age-matched reference population. Different reference files at rest and during stress might not be necessary. (orig.). With 3 figs., 3 tabs

  19. Spirometric reference values in urban children in Madagascar: poverty is a risk factor for low lung function.

    Science.gov (United States)

    Wolff, Peter Th; Arison, Lala; Rahajamiakatra, Abel; Raserijaona, Francis; Niggemann, Bodo

    2014-01-01

    Studies about children with respiratory diseases in Africa are impeded by the dearth of reliable data for the vast majority of countries on the continent. This study was conducted to establish representative reference values, therefore allowing a more accurate evaluation of lung function in Malagasy children. One thousand two hundred thirty-six students from three public and five private schools aged 8-12 years were recruited. A total of 1,093 children were healthy, had a valid lung function measurement and were thus deemed evaluable for this study. Lung function data were collected on consecutive days in Antananarivo, Madagascar's capital, using spirometry and a modified International Study of Asthma and Allergies in Childhood (ISAAC) questionnaire. The lung volumes found were substantially lower compared to Caucasian and African equations. The mean Z-score (Stanojevic) for the forced vital capacity (FVC) found was -1.45 and -0.93 for the forced expiratory volume in 1 sec (FEV1) with significant differences between private and public schools (FVC: P = 0.0023, FEV1: P = 0.0004). The equations established for school children in Madagascar's capital Antananarivo showed lung function values were lower than reference values for the same age group seen not only in European, but also in African American and African children. The unique ethnicity of the Malagasy people, which combines Southeast-Asian with substantial African influences, the heavy burden of pollution and poverty may explain these differences. © 2013 Wiley Periodicals, Inc.

  20. A Solution to the C-Value Paradox and the Function of Junk DNA: The Genome Balance Hypothesis.

    Science.gov (United States)

    Freeling, Michael; Xu, Jie; Woodhouse, Margaret; Lisch, Damon

    2015-06-01

    The Genome Balance Hypothesis originated from a recent study that provided a mechanism for the phenomenon of genome dominance in ancient polyploids: unique 24nt RNA coverage near genes is greater in genes on the recessive subgenome irrespective of differences in gene expression. 24nt RNAs target transposons. Transposon position effects are now hypothesized to balance the expression of networked genes and provide spring-like tension between pericentromeric heterochromatin and microtubules. The balance (coordination) of gene expression and centromere movement is under selection. Our hypothesis states that this balance can be maintained by many or few transposons about equally well. We explain known balanced distributions of junk DNA within genomes and between subgenomes in allopolyploids (and our hypothesis passes "the onion test" for any so-called solution to the C-value paradox). Importantly, when the allotetraploid maize chromosomes delete redundant genes, their nearby transposons are also lost; this result is explained if transposons near genes function. The Genome Balance Hypothesis is hypothetical because the position effect mechanisms implicated are not proved to apply to all junk DNA, and the continuous nature of the centromeric and gene position effects have not yet been studied as a single phenomenon. Copyright © 2015 The Author. Published by Elsevier Inc. All rights reserved.

  1. Acceptance of functional foods in Denmark, Finland and the US: A cross-cultural study of consumer values and preferences

    DEFF Research Database (Denmark)

    Bech-Larsen, Tino; Poulsen, Jacob; Grunert, Klaus G.

    1999-01-01

    Functional foods is a relatively new concept, which covers food products that are enriched with various kinds of (naturally occur-ring) components/substances (eg vitamins, minerals or probiotic cultures) or modified in a way so that the product provides an additional physio-lo-gical benefit...... that some consumers seem to approve of such manipu-lations whereas others don't. One possible explanation is differ-ences in con-sumers' values, especially the values pertaining to the relationship between man and nature. The aim of the study presented in this paper is, by means of conjoint analysis......, to study consumer acceptance of functional foods in Denmark, Finland and the United States and to investi-gate to which extent acceptance can be explained by consumer values. The three countries are selected due to differences in the importance attached to the value dimensions 'harmony' and 'mastery...

  2. Improved Steganographic Method Preserving Pixel-Value Differencing Histogram with Modulus Function

    Directory of Open Access Journals (Sweden)

    Heung-Kyu Lee

    2010-01-01

    Full Text Available We herein advance a secure steganographic algorithm that uses a turnover policy and a novel adjusting process. Although the method of Wang et al. uses Pixel-Value Differencing (PVD and their modulus function provides high capacity and good image quality, the embedding process causes a number of artifacts, such as abnormal increases and fluctuations in the PVD histogram, which may reveal the existence of the hidden message. In order to enhance the security of the algorithm, a turnover policy is used that prevents abnormal increases in the histogram values and a novel adjusting process is devised to remove the fluctuations at the border of the subrange in the PVD histogram. The proposed method therefore eliminates all the weaknesses of the PVD steganographic methods thus far proposed and guarantees secure communication. In the experiments described herein, the proposed algorithm is compared with other PVD steganographic algorithms by using well-known steganalysis techniques, such as RS-analysis, steganalysis for LSB matching, and histogram-based attacks. The results support our contention that the proposed method enhances security by keeping the PVD histogram similar to the cover, while also providing high embedding capacity and good imperceptibility to the naked eye.

  3. Neurons the decision makers, Part I: The firing function of a single neuron.

    Science.gov (United States)

    Saaty, Thomas

    2017-02-01

    This paper is concerned with understanding synthesis of electric signals in the neural system based on making pairwise comparisons. Fundamentally, every person and every animal are born with the talent to compare stimuli from things that share properties in space or over time. Comparisons always need experience to distinguish among things. Pairwise comparisons are numerically reciprocal. If a value is assigned to the larger of two elements that have a given property when compared with the smaller one, then the smaller has the reciprocal of that value when compared with the larger. Because making comparisons requires the reciprocal property, we need mathematics that can cope with division. There are four division algebras that would allow us to use our reciprocals arising from comparisons: The real numbers, the complex numbers, the non-commutative quaternions and the non-associative octonions. Rather than inferring function as from electric flow in a network, in this paper we infer the flow from function. Neurons fire in response to stimuli and their firings vary relative to the intensities of the stimuli. We believe neurons use some kind of pairwise comparison mechanism to determine when to fire based on the stimuli they receive. The ideas we develop here about flows are used to deduce how a system based on this kind of firing determination works and can be described. Furthermore the firing of neurons requires continuous comparisons. To develop a formula describing the output of these pairwise comparisons requires solving Fredholm's equation of the second kind which is satisfied if and only if a simple functional equation has solutions. The Fourier transform of the real solution of this equation leads to inverse square laws like those that are common in physics. The Fourier transform applied to a complex valued solution leads to Dirac type of firings. Such firings are dense in the very general fields of functions known as Sobolev spaces and thus can be used to

  4. On sign constant solutions of certain boundary value problems for second-order functional differential equations

    Czech Academy of Sciences Publication Activity Database

    Lomtatidze, Alexander; Vodstrčil, Petr

    2005-01-01

    Roč. 84, č. 2 (2005), s. 197-209 ISSN 0003-6811 Institutional research plan: CEZ:AV0Z10190503 Keywords : second order linear functional differential equations * nonnegative solution * two-point boundary value problem Subject RIV: BA - General Mathematics http://www.tandfonline.com/doi/full/10.1080/00036810410001724427

  5. Capturing patients' needs in casemix: a systematic literature review on the value of adding functioning information in reimbursement systems.

    Science.gov (United States)

    Hopfe, Maren; Stucki, Gerold; Marshall, Ric; Twomey, Conal D; Üstün, T Bedirhan; Prodinger, Birgit

    2016-02-03

    Contemporary casemix systems for health services need to ensure that payment rates adequately account for actual resource consumption based on patients' needs for services. It has been argued that functioning information, as one important determinant of health service provision and resource use, should be taken into account when developing casemix systems. However, there has to date been little systematic collation of the evidence on the extent to which the addition of functioning information into existing casemix systems adds value to those systems with regard to the predictive power and resource variation explained by the groupings of these systems. Thus, the objective of this research was to examine the value of adding functioning information into casemix systems with respect to the prediction of resource use as measured by costs and length of stay. A systematic literature review was performed. Peer-reviewed studies, published before May 2014 were retrieved from CINAHL, EconLit, Embase, JSTOR, PubMed and Sociological Abstracts using keywords related to functioning ('Functioning', 'Functional status', 'Function*, 'ICF', 'International Classification of Functioning, Disability and Health', 'Activities of Daily Living' or 'ADL') and casemix systems ('Casemix', 'case mix', 'Diagnosis Related Groups', 'Function Related Groups', 'Resource Utilization Groups' or 'AN-SNAP'). In addition, a hand search of reference lists of included articles was conducted. Information about study aims, design, country, setting, methods, outcome variables, study results, and information regarding the authors' discussion of results, study limitations and implications was extracted. Ten included studies provided evidence demonstrating that adding functioning information into casemix systems improves predictive ability and fosters homogeneity in casemix groups with regard to costs and length of stay. Collection and integration of functioning information varied across studies. Results suggest

  6. NLP modeling for the optimization of LiBr-H_2O absorption refrigeration systems with exergy loss rate, heat transfer area, and cost as single objective functions

    International Nuclear Information System (INIS)

    Mussati, Sergio F.; Gernaey, Krist V.; Morosuk, Tatiana; Mussati, Miguel C.

    2016-01-01

    Highlights: • A NLP model is used for simultaneous optimization of sizes and operating conditions. • Total exergy loss rate and transfer area are optimized as single objective functions. • Theoretical and practical bounds for cost optimization problems are computed. • A systematic solution strategy is proposed for total annual cost optimization. • Relevance of components is ranked by heat transfer area, exergy loss rate, and cost. - Abstract: Based on a nonlinear mathematical programming model, the sizes and operating conditions of the process units of single-effect absorption refrigeration systems operating with a LiBr–H_2O solution are optimized for a specified cooling capacity by minimizing three single objective functions: the total exergy loss rate, the total heat transfer area, and the total annual cost of the system. It was found that the optimal solution obtained by minimization of the total exergy loss rate provides “theoretical” upper bounds not only for the total heat transfer area of the system but also for each process unit and all stream temperatures, while the optimal solution obtained by minimization of the total heat transfer area provides the lower bounds for these model variables, to solve a cost optimization problem. The minimization of the total exergy loss rate by varying parametrically the available total heat transfer area between these bounds was also performed, allowing to see how the optimal distribution of the available total heat transfer area among the system components, as well as the operating conditions (stream temperature, pressure, composition, and mass flow rate) and heat loads, vary qualitatively and quantitatively with increasing available total heat transfer area. These optimization results allowed to find a “practical” value of the total heat transfer area, i.e. no benefits can be obtained by increasing the available total heat transfer area above this value since the minimal total exergy loss value cannot

  7. Assessment of left ventricular function using 201Tl electrocardiogram-gated myocardial single photon emission computed tomography

    International Nuclear Information System (INIS)

    Nishikubo, Naotsugu; Tamai, Hiroyuki

    2013-01-01

    Advances in computed tomography (CT) technology make it possible to obtain left ventricular wall motion using 3D reconstruction. In this study, we compared the images obtained from CT and 201 Tl electrocardiogram (ECG) gated single photon emission computed tomography (SPECT). In 20 patients with ischemic heart disease, we performed 201 Tl ECG gated SPECT (GE Healthcare Millennium VG) and ECG gated CT (Philips Medical Systems Brilliance iCT) to evaluate of left ventricular wall motion during the resting phase. In SPECT, left ventricular images were reconstructed using quantitative gated SPECT (QGS) software. In CT, the images were reconstructed using Virtual Place (AZE Software). The left ventricle was classified into five regions (anterior, lateral, inferior, septal, and apical). The amplitude of the wall motion was classified into five grades according to AHA classification. The values of the wall motion were separately checked by two radiographers. Assessment of left ventricular function myocardial wall movement using the three-dimensional movie display with ECG gated myocardial SPECT data was in agreement with the evaluation by cardiac CT inspection, and corresponded with wall motion in 88 of all 100 segments. SPECT analysis has the same quantity as that of obtained from CT for evaluation of left ventricular wall motion. (author)

  8. Parental Autonomy Granting and School Functioning among Chinese Adolescents: The Moderating Role of Adolescents’ Cultural Values

    Directory of Open Access Journals (Sweden)

    Cixin Wang

    2017-12-01

    Full Text Available School adjustment and achievement are important indicators of adolescents’ well-being; however, few studies have examined the risk and protective factors predicting students’ school adjustment and achievement at the individual, familial, and cultural level. The present study examined the influences of individual and familial factors and cultural values on Chinese adolescents’ school functioning (e.g., school adjustment and grades. It also tested whether cultural values moderated the relationship between parenting and adolescents’ school functioning. Self-report data were collected from a stratified random sample of 2,864 adolescents (51.5% female, mean age = 15.52 years, grade 6th – 12th from 55 classrooms, in 13 schools in Shanghai, China. Results showed that self-esteem (bse→adj = 0.05, SE = 0.01, p < 0.001; bse→grades = 0.08, SE = 0.02, p < 0.001, parent–adolescent conflict (bconflict→adj = -0.03, SE = 0.00, p < 0.001; bconflict→grades = -0.04, SE = 0.01, p < 0.001, and conformity to parental expectations (bconform→adj = -0.03, SE = 0.02, p < 0.05; bconform→grades = 0.10, SE = 0.04, p < 0.05 all had significant effects on both school adjustment and grades, respectively. More importantly, results showed that independent self-construal moderated the relationship between parental autonomy granting and adolescents’ grades (bindepxautom = 0.06, SE = 0.02, p < 0.01. The findings suggest that cultural values may influence adolescents’ appraisal of parental autonomy granting, which then impacts their school functioning.

  9. Existence of positive solutions for boundary value problems of fractional functional differential equations

    Directory of Open Access Journals (Sweden)

    Chuanzhi Bai

    2010-06-01

    Full Text Available This paper deals with the existence of positive solutions for a boundary value problem involving a nonlinear functional differential equation of fractional order $\\alpha$ given by $ D^{\\alpha} u(t + f(t, u_t = 0$, $t \\in (0, 1$, $2 < \\alpha \\le 3$, $ u^{\\prime}(0 = 0$, $u^{\\prime}(1 = b u^{\\prime}(\\eta$, $u_0 = \\phi$. Our results are based on the nonlinear alternative of Leray-Schauder type and Krasnosel'skii fixed point theorem.

  10. Regular Functions with Values in Ternary Number System on the Complex Clifford Analysis

    Directory of Open Access Journals (Sweden)

    Ji Eun Kim

    2013-01-01

    Full Text Available We define a new modified basis i^ which is an association of two bases, e1 and e2. We give an expression of the form z=x0+ i ^z0-, where x0 is a real number and z0- is a complex number on three-dimensional real skew field. And we research the properties of regular functions with values in ternary field and reduced quaternions by Clifford analysis.

  11. The Use of Asymptotic Functions for Determining Empirical Values of CN Parameter in Selected Catchments of Variable Land Cover

    Directory of Open Access Journals (Sweden)

    Wałęga Andrzej

    2017-12-01

    Full Text Available The aim of the study was to assess the applicability of asymptotic functions for determining the value of CN parameter as a function of precipitation depth in mountain and upland catchments. The analyses were carried out in two catchments: the Rudawa, left tributary of the Vistula, and the Kamienica, right tributary of the Dunajec. The input material included data on precipitation and flows for a multi-year period 1980–2012, obtained from IMGW PIB in Warsaw. Two models were used to determine empirical values of CNobs parameter as a function of precipitation depth: standard Hawkins model and 2-CN model allowing for a heterogeneous nature of a catchment area.

  12. Picomolar selective detection of mercuric ion (Hg{sup 2+}) using a functionalized single plasmonic gold nanoparticle

    Energy Technology Data Exchange (ETDEWEB)

    Song, Hyeon Don; Choi, Inhee; Yang, Young In; Hong, Surin; Lee, Suseung; Yi, Jongheop [School of Chemical and Biological Engineering, Institute of Chemical Processes, Seoul National University, Seoul 151-742 (Korea, Republic of); Kang, Taewook, E-mail: xinly601@snu.ac.kr, E-mail: iniini79@snu.ac.kr, E-mail: netmo00@snu.ac.kr, E-mail: pell2004@snu.ac.kr, E-mail: jazz1863@snu.ac.kr, E-mail: twkang@sogang.ac.kr, E-mail: jyi@snu.ac.kr [Department of Chemical and Biomolecular Engineering, Sogang University, Seoul 121-742 (Korea, Republic of)

    2010-04-09

    A highly sensitive method for the selective detection and quantification of mercuric ions (Hg{sup 2+}) using single plasmonic gold nanoparticle (GNP)-based dark-field microspectroscopy (DFMS) is demonstrated. The method is based on the scattering property of a single GNP that is functionalized with thiolated molecules, which is altered when analytes bind to the functionalized GNP. The spectral resolution of the system is 0.26 nm and a linear response to Hg{sup 2+} was found in the dynamic range of 100 pM-10 {mu}M. The method permits Hg{sup 2+} to be detected at the picomolar level, which is a remarkable reduction in the detection limit, considering the currently proscribed Environmental Protection Agency regulation level (10 nM, or 2 ppb) and the detection limits of other optical methods for detecting Hg{sup 2+} (recently approx. 1-10 nM). In addition, Hg{sup 2+} can be sensitively detected in the presence of Cd{sup 2+}, Pb{sup 2+}, Cu{sup 2+}, Zn{sup 2+} and Ni{sup 2+}, which do not interfere with the analysis. Based on the findings reported herein, it is likely that single-nanoparticle-based metal ion sensing can be extended to the development of other chemo- and biosensors for the direct detection of specific targets in an intracellular environment as well as in environmental monitoring.

  13. Advances in single chain technology.

    Science.gov (United States)

    Gonzalez-Burgos, Marina; Latorre-Sanchez, Alejandro; Pomposo, José A

    2015-10-07

    The recent ability to manipulate and visualize single atoms at atomic level has given rise to modern bottom-up nanotechnology. Similar exquisite degree of control at the individual polymeric chain level for producing functional soft nanoentities is expected to become a reality in the next few years through the full development of so-called "single chain technology". Ultra-small unimolecular soft nano-objects endowed with useful, autonomous and smart functions are the expected, long-term valuable output of single chain technology. This review covers the recent advances in single chain technology for the construction of soft nano-objects via chain compaction, with an emphasis in dynamic, letter-shaped and compositionally unsymmetrical single rings, complex multi-ring systems, single chain nanoparticles, tadpoles, dumbbells and hairpins, as well as the potential end-use applications of individual soft nano-objects endowed with useful functions in catalysis, sensing, drug delivery and other uses.

  14. Analysis of reproducibility of the single photon tomography reconstruction by the method of singular value decomposition

    International Nuclear Information System (INIS)

    Devaux, J.Y.; Mazelier, L.; Lefkopoulos, D.

    1997-01-01

    We have earlier shown that the method of singular value decomposition (SVD) allows the image reconstruction in single-photon-tomography with precision higher than the classical method of filtered back-projections. Actually, the establishing of an elementary response matrix which incorporates both the photon attenuation phenomenon, the scattering, the translation non-invariance principle and the detector response, allows to take into account the totality of physical parameters of acquisition. By an non-consecutive optimized truncation of the singular values we have obtained a significant improvement in the efficiency of the regularization of bad conditioning of this problem. The present study aims at verifying the stability of this truncation under modifications of acquisition conditions. Two series of parameters were tested, first, those modifying the geometry of acquisition: the influence of rotation center, the asymmetric disposition of the elementary-volume sources against the detector and the precision of rotation angle, and secondly, those affecting the correspondence between the matrix and the space to be reconstructed: the effect of partial volume and a noise propagation in the experimental model. For the parameters which introduce a spatial distortion, the alteration of reconstruction has been, as expected, comparable to that observed with the classical reconstruction and proportional with the amplitude of shift from the normal one. In exchange, for the effect of partial volume and of noise, the study of truncation signature revealed a variation in the optimal choice of the conserved singular values but with no effect on the global precision of reconstruction

  15. Methods for evaluation of platelet function.

    Science.gov (United States)

    Lindahl, Tomas L; Ramström, Sofia

    2009-10-01

    There are a multitude of platelet function tests available, reflecting the complex nature of the platelet in haemostasis. No simple single test will ever cover all aspects of platelet function. Some tests focus on the aggregation of platelets, for example aggregometry, other on the swelling in response to hypotonic solutions, i.e. the well-known hypotonic shock response, or adhesion or coagulation and clot retraction, for example thromboelastography. In general there is a lack of clinical studies showing a predictive value of analysis of platelet concentrates.

  16. Implications of the single supervisory mechanism on ECB's functions and on credit institutions' activity

    Directory of Open Access Journals (Sweden)

    Teodora Cristina BARBU

    2013-03-01

    Full Text Available The European Commission's proposal launched on September 12, 2012 for conferring the European Central Bank extended powers in the field of Euro zone banking supervision has become a hotly debated topic across EU member states. Until now, there is still strong resilience of the EU countries outside the single currency area.The prospects for its practical implementation raised, however, a series of questions related to its technical feasibility. Our paper intends to shed light on some issues concerning the implications of the single monitoring mechanism on the traditional functions of the ECB, on the coexistence between supranational supervision and the national one, and on various facets of the impact that the new architecture of European banking supervision will have on the business of credit institutions, in terms of performance indicators, efficiency, risk and competition.

  17. The electronic fine structure of 4-nitrophenyl functionalized single-walled carbon nanotubes

    International Nuclear Information System (INIS)

    Chakraborty, Amit K; Coleman, Karl S; Dhanak, Vinod R

    2009-01-01

    Controlling the electronic structure of carbon nanotubes (CNTs) is of great importance to various CNT based applications. Herein the electronic fine structure of single-walled carbon nanotube films modified with 4-nitrophenyl groups, produced following reaction with 4-nitrobenzenediazonium tetrafluoroborate, was investigated for the first time. Various techniques such as x-ray and ultra-violet photoelectron spectroscopy, and near edge x-ray absorption fine structure studies were used to explore the electronic structure, and the results were compared with the measured electrical resistances. A reduction in number of the π electronic states in the valence band consistent with the increased resistance of the functionalized nanotube films was observed.

  18. Nonadiabatic Dynamics in Single-Electron Tunneling Devices with Time-Dependent Density-Functional Theory

    Science.gov (United States)

    Dittmann, Niklas; Splettstoesser, Janine; Helbig, Nicole

    2018-04-01

    We simulate the dynamics of a single-electron source, modeled as a quantum dot with on-site Coulomb interaction and tunnel coupling to an adjacent lead in time-dependent density-functional theory. Based on this system, we develop a time-nonlocal exchange-correlation potential by exploiting analogies with quantum-transport theory. The time nonlocality manifests itself in a dynamical potential step. We explicitly link the time evolution of the dynamical step to physical relaxation timescales of the electron dynamics. Finally, we discuss prospects for simulations of larger mesoscopic systems.

  19. A multistep single-crystal-to-single-crystal bromodiacetylene dimerization

    Science.gov (United States)

    Hoheisel, Tobias N.; Schrettl, Stephen; Marty, Roman; Todorova, Tanya K.; Corminboeuf, Clémence; Sienkiewicz, Andrzej; Scopelliti, Rosario; Schweizer, W. Bernd; Frauenrath, Holger

    2013-04-01

    Packing constraints and precise placement of functional groups are the reason that organic molecules in the crystalline state often display unusual physical or chemical properties not observed in solution. Here we report a single-crystal-to-single-crystal dimerization of a bromodiacetylene that involves unusually large atom displacements as well as the cleavage and formation of several bonds. Density functional theory computations support a mechanism in which the dimerization is initiated by a [2 + 1] photocycloaddition favoured by the nature of carbon-carbon short contacts in the crystal structure. The reaction proceeded up to the theoretical degree of conversion without loss of crystallinity, and it was also performed on a preparative scale with good yield. Moreover, it represents the first synthetic pathway to (E)-1,2-dibromo-1,2-diethynylethenes, which could serve as synthetic intermediates for the preparation of molecular carbon scaffolds. Our findings both extend the scope of single-crystal-to-single-crystal reactions and highlight their potential as a synthetic tool for complex transformations.

  20. Tilted Light Sheet Microscopy with 3D Point Spread Functions for Single-Molecule Super-Resolution Imaging in Mammalian Cells.

    Science.gov (United States)

    Gustavsson, Anna-Karin; Petrov, Petar N; Lee, Maurice Y; Shechtman, Yoav; Moerner, W E

    2018-02-01

    To obtain a complete picture of subcellular nanostructures, cells must be imaged with high resolution in all three dimensions (3D). Here, we present tilted light sheet microscopy with 3D point spread functions (TILT3D), an imaging platform that combines a novel, tilted light sheet illumination strategy with engineered long axial range point spread functions (PSFs) for low-background, 3D super localization of single molecules as well as 3D super-resolution imaging in thick cells. TILT3D is built upon a standard inverted microscope and has minimal custom parts. The axial positions of the single molecules are encoded in the shape of the PSF rather than in the position or thickness of the light sheet, and the light sheet can therefore be formed using simple optics. The result is flexible and user-friendly 3D super-resolution imaging with tens of nm localization precision throughout thick mammalian cells. We validated TILT3D for 3D super-resolution imaging in mammalian cells by imaging mitochondria and the full nuclear lamina using the double-helix PSF for single-molecule detection and the recently developed Tetrapod PSF for fiducial bead tracking and live axial drift correction. We envision TILT3D to become an important tool not only for 3D super-resolution imaging, but also for live whole-cell single-particle and single-molecule tracking.

  1. Tilted light sheet microscopy with 3D point spread functions for single-molecule super-resolution imaging in mammalian cells

    Science.gov (United States)

    Gustavsson, Anna-Karin; Petrov, Petar N.; Lee, Maurice Y.; Shechtman, Yoav; Moerner, W. E.

    2018-02-01

    To obtain a complete picture of subcellular nanostructures, cells must be imaged with high resolution in all three dimensions (3D). Here, we present tilted light sheet microscopy with 3D point spread functions (TILT3D), an imaging platform that combines a novel, tilted light sheet illumination strategy with engineered long axial range point spread functions (PSFs) for low-background, 3D super localization of single molecules as well as 3D super-resolution imaging in thick cells. TILT3D is built upon a standard inverted microscope and has minimal custom parts. The axial positions of the single molecules are encoded in the shape of the PSF rather than in the position or thickness of the light sheet, and the light sheet can therefore be formed using simple optics. The result is flexible and user-friendly 3D super-resolution imaging with tens of nm localization precision throughout thick mammalian cells. We validated TILT3D for 3D superresolution imaging in mammalian cells by imaging mitochondria and the full nuclear lamina using the double-helix PSF for single-molecule detection and the recently developed Tetrapod PSF for fiducial bead tracking and live axial drift correction. We envision TILT3D to become an important tool not only for 3D super-resolution imaging, but also for live whole-cell single-particle and single-molecule tracking.

  2. FUNCTIONAL IMPLICATIONS OF THE CLOCK 3111T/C SINGLE-NUCLEOTIDE POLYMORPHISM

    Directory of Open Access Journals (Sweden)

    Angela Renee Ozburn

    2016-04-01

    Full Text Available Circadian rhythm disruptions are prominently associated with Bipolar Disorder (BD. Circadian rhythms are regulated by the molecular clock, a family of proteins that function together in a transcriptional-translational feedback loop. The CLOCK protein is a key transcription factor of this feedback loop, and previous studies have found that manipulations of the Clock gene are sufficient to produce manic-like behavior in mice (Roybal et al., 2007. The Clock 3111T/C single-nucleotide polymorphism (SNP; rs1801260 is a genetic variation of the human Clock gene that is significantly associated with increased frequency of manic episodes in BD patients (Benedetti et al., 2003. The 3111T/C SNP is located in the 3’ untranslated region of the Clock gene. In this study, we sought to examine the functional implications of the human Clock 3111T/C SNP by transfecting a mammalian cell line (mouse embryonic fibroblasts isolated from Clock -/- knockout mice with pcDNA plasmids containing the human Clock gene with either the T or C SNP at position 3111. We then measured circadian gene expression over a 24 hour time period. We found that the Clock3111C SNP resulted in higher mRNA levels than the Clock 3111T SNP. Further, we found that Per2, a transcriptional target of CLOCK, was also more highly expressed with Clock 3111C expression, indicating the 3’UTR SNP affects the expression, function and stability of Clock mRNA.

  3. Effect of the single-scattering phase function on light transmission through disordered media with large inhomogeneities

    International Nuclear Information System (INIS)

    Marinyuk, V V; Sheberstov, S V

    2017-01-01

    We calculate the total transmission coefficient (transmittance) of a disordered medium with large (compared to the light wavelength) inhomogeneities. To model highly forward scattering in the medium we take advantage of the Gegenbauer kernel phase function. In a subdiffusion thickness range, the transmittance is shown to be sensitive to the specific form of the single-scattering phase function. The effect reveals itself at grazing angles of incidence and originates from small-angle multiple scattering of light. Our results are in a good agreement with numerical solutions to the radiative transfer equation. (paper)

  4. Relative excitation functions for singly-excited and core-excited levels of S V--S IX populated by the beam-foil interaction

    International Nuclear Information System (INIS)

    Moenke, D.; Bengtsson, P.; Engstroem, L.; Hutton, R.; Jupen, C.; Kirm, M.; Westerlind, M.

    1994-01-01

    We have investigated the relative excitation functions for low-lying singly excited and low-lying core-excited levels in S V (S 4+ ) to S IX (S 8+ ) after beam-foil excitation using ions in the energy range 2--10 MeV. The spectral line intensities have been normalized to the same number of particles at each ion energy and corrections for the level lifetimes have been made. The overall accuracy of the measured relative excitation function at each energy and charge state is estimated to be better than 2%. A comparison of the relative excitation functions for singly excited and core-excited lines shows a difference in S VII, but not in S VI

  5. Investigation of photobleaching and saturation of single molecules by fluorophore recrossing events

    Energy Technology Data Exchange (ETDEWEB)

    Burrows, Sean M.; Reif, Randall D. [Department of Chemistry and Biochemistry, Texas Tech University, Lubbock, TX 79409-1061 (United States); Pappas, Dimitri [Department of Chemistry and Biochemistry, Texas Tech University, Lubbock, TX 79409-1061 (United States)], E-mail: d.pappas@ttu.edu

    2007-08-15

    A method for investigation of photobleaching and saturation of single molecules by fluorophore recrossing events in a laser beam is described. The diffraction-limited probe volumes encountered in single-molecule detection (SMD) produce high excitation irradiance, which can decrease available signal. The single molecules of several dyes were detected and the data was used to extract interpeak times above a defined threshold value. The interpeak times revealed the number of fluorophore recrossing events. The number of molecules detected that were within 2 ms of each other represented a molecular recrossing for this work. Calcein, fluorescein and R-phycoerythrin were analyzed and the saturation irradiance and photobleaching effects were determined as a function of irradiance. This approach is simple and it serves as a method of optimizing experimental conditions for single-molecule detection.

  6. 38 CFR 8.11 - Cash value and policy loan.

    Science.gov (United States)

    2010-07-01

    ... will be taken as the date of delivery. (c) All values, reserves and net single premiums on..., reserves, and net single premiums issued under the provisions of section 1922(a) of title 38 U.S.C., and on...: 38 U.S.C. 1904, 1906) (e) All values on insurance, reserves, and net single premiums issued under the...

  7. Fractional parts and their relations to the values of the Riemann zeta function

    KAUST Repository

    Alabdulmohsin, Ibrahim

    2017-09-06

    A well-known result, due to Dirichlet and later generalized by de la Vallée–Poussin, expresses a relationship between the sum of fractional parts and the Euler–Mascheroni constant. In this paper, we prove an asymptotic relationship between the summation of the products of fractional parts with powers of integers on the one hand, and the values of the Riemann zeta function, on the other hand. Dirichlet’s classical result falls as a particular case of this more general theorem.

  8. Fractional parts and their relations to the values of the Riemann zeta function

    KAUST Repository

    Alabdulmohsin, Ibrahim

    2017-01-01

    A well-known result, due to Dirichlet and later generalized by de la Vallée–Poussin, expresses a relationship between the sum of fractional parts and the Euler–Mascheroni constant. In this paper, we prove an asymptotic relationship between the summation of the products of fractional parts with powers of integers on the one hand, and the values of the Riemann zeta function, on the other hand. Dirichlet’s classical result falls as a particular case of this more general theorem.

  9. A step function model to evaluate the real monetary value of man-sievert with real GDP

    International Nuclear Information System (INIS)

    Na, Seong H.; Kim, Sun G.

    2009-01-01

    For use in a cost-benefit analysis to establish optimum levels of radiation protection in Korea under the ALARA principle, we introduce a discrete step function model to evaluate man-sievert monetary value in the real economic value. The model formula, which is unique and country-specific, is composed of real GDP, the nominal risk coefficient for cancer and hereditary effects, the aversion factor against radiation exposure, and average life expectancy. Unlike previous researches on alpha-value assessment, we show different alpha values in the real term, differentiated with respect to the range of individual doses, which would be more realistic and informative for application to the radiation protection practices. GDP deflators of economy can reflect the society's situations. Finally, we suggest that the Korean model can be generalized simply to other countries without normalizing any country-specific factors.

  10. A step function model to evaluate the real monetary value of man-sievert with real GDP

    Energy Technology Data Exchange (ETDEWEB)

    Na, Seong H. [Korea Institute of Nuclear Safety, 19 Guseong-dong, Yuseong-gu, Daejeon 305-338 (Korea, Republic of)], E-mail: shna@kins.re.kr; Kim, Sun G. [School of Business, Daejeon University, Yong Woon-dong, Dong-gu, Daejeon 300-716 (Korea, Republic of)], E-mail: sunkim@dju.ac.kr

    2009-07-15

    For use in a cost-benefit analysis to establish optimum levels of radiation protection in Korea under the ALARA principle, we introduce a discrete step function model to evaluate man-sievert monetary value in the real economic value. The model formula, which is unique and country-specific, is composed of real GDP, the nominal risk coefficient for cancer and hereditary effects, the aversion factor against radiation exposure, and average life expectancy. Unlike previous researches on alpha-value assessment, we show different alpha values in the real term, differentiated with respect to the range of individual doses, which would be more realistic and informative for application to the radiation protection practices. GDP deflators of economy can reflect the society's situations. Finally, we suggest that the Korean model can be generalized simply to other countries without normalizing any country-specific factors.

  11. A step function model to evaluate the real monetary value of man-sievert with real GDP.

    Science.gov (United States)

    Na, Seong H; Kim, Sun G

    2009-01-01

    For use in a cost-benefit analysis to establish optimum levels of radiation protection in Korea under the ALARA principle, we introduce a discrete step function model to evaluate man-sievert monetary value in the real economic value. The model formula, which is unique and country-specific, is composed of real GDP, the nominal risk coefficient for cancer and hereditary effects, the aversion factor against radiation exposure, and average life expectancy. Unlike previous researches on alpha-value assessment, we show different alpha values in the real term, differentiated with respect to the range of individual doses, which would be more realistic and informative for application to the radiation protection practices. GDP deflators of economy can reflect the society's situations. Finally, we suggest that the Korean model can be generalized simply to other countries without normalizing any country-specific factors.

  12. Linearized semiclassical initial value time correlation functions with maximum entropy analytic continuation.

    Science.gov (United States)

    Liu, Jian; Miller, William H

    2008-09-28

    The maximum entropy analytic continuation (MEAC) method is used to extend the range of accuracy of the linearized semiclassical initial value representation (LSC-IVR)/classical Wigner approximation for real time correlation functions. LSC-IVR provides a very effective "prior" for the MEAC procedure since it is very good for short times, exact for all time and temperature for harmonic potentials (even for correlation functions of nonlinear operators), and becomes exact in the classical high temperature limit. This combined MEAC+LSC/IVR approach is applied here to two highly nonlinear dynamical systems, a pure quartic potential in one dimensional and liquid para-hydrogen at two thermal state points (25 and 14 K under nearly zero external pressure). The former example shows the MEAC procedure to be a very significant enhancement of the LSC-IVR for correlation functions of both linear and nonlinear operators, and especially at low temperature where semiclassical approximations are least accurate. For liquid para-hydrogen, the LSC-IVR is seen already to be excellent at T=25 K, but the MEAC procedure produces a significant correction at the lower temperature (T=14 K). Comparisons are also made as to how the MEAC procedure is able to provide corrections for other trajectory-based dynamical approximations when used as priors.

  13. The diagnostic value of radionuclide hysterosalphingography on oviduct function in infertile women

    International Nuclear Information System (INIS)

    Liu Zhixiang; Li Guangyu; Li Zhigang; Dong Jian; Ren Chun'e; Li Yanmin; Jiang Aifang

    2006-01-01

    Objective: To study the criteria of normal and abnormal oviduct function and the difference of oviduct function between the primary and secondary infertile patients. Methods: Twenty-nine cases of normal controls and 126 infertile women were imaged by improved radionuclide hysterosalpingography (RNHS). Results: In the normal control group with small dose fractional injection of 99 Tc m -macroaggregated albumin (MAA) into cervical canal, the appearance time of radioactivity in ovarian tube by dynamic imaging was (4.0±2.7) s. When there was much more liquid retained in uterus, the ovarian appearance time delayed to (18.0±1.2) s. Combined the injection under pressure and second dynamic imaging in all 252 ovarian tubes of 126 cases, the damaged fallopian tubes could be divided into six patterns. Among all of the infertile women whose fallopian tubes showed mechanical patency by the X-ray hysterosalpingography (HSG), their positivity of damaged fallopian tube fuction reached 70.5% by RNHS. Besides, the mild and severe functional abnormality of fallopian tube in patients of primary and secondary infertility were 20.3% and 11.9% versus 14.9% and 17.9% respectively. Conclusion: Modified RNHS has important diagnostic value for judgment of the damage magnitude and patency of fallopian tube in infertile women. (authors)

  14. Single particle level density in a finite depth potential well

    International Nuclear Information System (INIS)

    Shlomo, S.; Kolomietz, V.M.; Dejbakhsh, H.

    1997-01-01

    We consider the single particle level density g(ε) of a realistic finite depth potential well, concentrating on the continuum (ε>0) region. We carry out quantum-mechanical calculations of the partial level density g l (ε), associated with a well-defined orbital angular momentum l≤40, using the phase-shift derivative method and the Greens-function method and compare the results with those obtained using the Thomas-Fermi approximation. We also numerically calculate g(ε) as a l sum of g l (ε) up to a certain value of scr(l) max ≤40 and determine the corresponding smooth level densities using the Strutinsky smoothing procedure. We demonstrate, in accordance with Levinson close-quote s theorem, that the partial contribution g l (ε) to the single particle level density from continuum states has positive and negative values. However, g(ε) is nonnegative. We also point out that this is not the case for an energy-dependent potential well. copyright 1997 The American Physical Society

  15. Value Engineering and Function Analysis: Frameworks for Innovation in Antenna Systems

    Directory of Open Access Journals (Sweden)

    Hamid Reza Fartookzadeh

    2018-04-01

    Full Text Available Value engineering (VE and function analysis (FA are technological tools for the functional enhancement and cost reduction of engineering projects. They also help to overcome mental inertia by acknowledging the voice of the customer in complicated systems. Antenna engineering, providing electromagnetic remote links, is an important area in engineering science, with a large number of innovative concepts. However, managing innovative ideas to improve performance, reliability, quality, safety, and reduce life cycle costs, is still a work in progress. This research was designed to apply VE and FA as frameworks for innovative ideas in antenna systems, especially with regard to imaging and radar systems. FA diagrams free a designers’ mind from tools to instead focus on purpose, which can help them to obtain better ideas for solutions to problems. It was identified that there were several options available for functionality enhancement and cost reduction. The required functionalities of the components of antenna systems, and their advantages and limitations were indicated. In addition, it was identified that some of the advantages and limitations appeared for combinations of the components. Alternative methods for applications, such as polarization conversion and the separation of outgoing and incoming electromagnetic waves, were studied. Circular polarization (CP is important for two-way communication, since left-handed circularly polarized waves usually return with right-handed CP from targets. Therefore, various methods for producing CP were discussed, such as metamaterial-based linear to circular polarization converters and waveguide polarizers. Also, potential extra applications for these systems were explained. Two examples were: (1 merging multiple systems with different operating frequencies using multiband components; and (2 applying a feeding system for multiple reflectors using surfaces that reflect half of the wave and transmit the other

  16. Time-dependent importance sampling in semiclassical initial value representation calculations for time correlation functions. II. A simplified implementation.

    Science.gov (United States)

    Tao, Guohua; Miller, William H

    2012-09-28

    An efficient time-dependent (TD) Monte Carlo (MC) importance sampling method has recently been developed [G. Tao and W. H. Miller, J. Chem. Phys. 135, 024104 (2011)] for the evaluation of time correlation functions using the semiclassical (SC) initial value representation (IVR) methodology. In this TD-SC-IVR method, the MC sampling uses information from both time-evolved phase points as well as their initial values, and only the "important" trajectories are sampled frequently. Even though the TD-SC-IVR was shown in some benchmark examples to be much more efficient than the traditional time-independent sampling method (which uses only initial conditions), the calculation of the SC prefactor-which is computationally expensive, especially for large systems-is still required for accepted trajectories. In the present work, we present an approximate implementation of the TD-SC-IVR method that is completely prefactor-free; it gives the time correlation function as a classical-like magnitude function multiplied by a phase function. Application of this approach to flux-flux correlation functions (which yield reaction rate constants) for the benchmark H + H(2) system shows very good agreement with exact quantum results. Limitations of the approximate approach are also discussed.

  17. Comparison between total lung capacity and residual volume values obtained by pletysmography and single breath methods with methane

    Directory of Open Access Journals (Sweden)

    Ricardo Marques Dias

    2006-11-01

    Full Text Available We analyzed pulmonary function tests of twenty asthmatic patients from Gaffrée e Guinle University Hospital, classified according to Brazilian Guidelines for Asthma (2002, similar to GINA, into mild persistent or moderate (9 or severe (11 asthma. We obtained parameters from spirometry, plethysmograph(PL and single breath technique for diffusion capacity (SB, with methane. Total lung capacity and residual volume were called TLCPL and RVPL when measured by pletysmography and TLCSB and RVSB when determined by single breath test. There were 13 women and 7 men with mean age of 47.6 years. The pulmonary dysfunction degree to FEV1/FVC was 58.8% with CI95=53.9 to 63.6. The mean values in litres for TLCPL (5.94 and RVPL (2.55 were significantly higher than for TLCSB (4.73 and RVSB (1.66. Multiple regression equations were determined for TLCPL e RVPL using only single breath values, TLCSB or RVSB, and spirographic parameters, with significant regression coefficients. However, the inclusion of spirometric parameters, except for FVC, did not improve the predicted capacity for the equations. Considering only the TLCSB, r2=0.79, the equation is: TLCPL=(TLCSB*1.025+1.088, with EPE=0.64. The regression for RVPL, r2=0.23, is: RVPL=(RVSB*0.9268+1.012. The results obtained after bronchodilation with 400 mcg of salbutamol did not improve the regression. We concluded that the SB technique did not obtain the same results as pletysmography for TLC and RV, but for TLC this difference can be predicted. Resumo: Foram analisados exames de função pulmonar de 20 asmáticos, em acompanhamento no HU Gaffrée Guinle, classificados, segundo o Consenso Brasileiro (2002, em asma leve persistente ou moderada (9 e grave (11. Foram obtidos os valores dos parâmetros da espirografia, da pletismografia e da técnica de respiração única, com metano, para a medida da difusão pulmonar (DLco. Assim, a capacidade pulmonar total e o volume residual, quando

  18. Angstrom-Resolution Magnetic Resonance Imaging of Single Molecules via Wave-Function Fingerprints of Nuclear Spins

    Science.gov (United States)

    Ma, Wen-Long; Liu, Ren-Bao

    2016-08-01

    Single-molecule sensitivity of nuclear magnetic resonance (NMR) and angstrom resolution of magnetic resonance imaging (MRI) are the highest challenges in magnetic microscopy. Recent development in dynamical-decoupling- (DD) enhanced diamond quantum sensing has enabled single-nucleus NMR and nanoscale NMR. Similar to conventional NMR and MRI, current DD-based quantum sensing utilizes the "frequency fingerprints" of target nuclear spins. The frequency fingerprints by their nature cannot resolve different nuclear spins that have the same noise frequency or differentiate different types of correlations in nuclear-spin clusters, which limit the resolution of single-molecule MRI. Here we show that this limitation can be overcome by using "wave-function fingerprints" of target nuclear spins, which is much more sensitive than the frequency fingerprints to the weak hyperfine interaction between the targets and a sensor under resonant DD control. We demonstrate a scheme of angstrom-resolution MRI that is capable of counting and individually localizing single nuclear spins of the same frequency and characterizing the correlations in nuclear-spin clusters. A nitrogen-vacancy-center spin sensor near a diamond surface, provided that the coherence time is improved by surface engineering in the near future, may be employed to determine with angstrom resolution the positions and conformation of single molecules that are isotope labeled. The scheme in this work offers an approach to breaking the resolution limit set by the "frequency gradients" in conventional MRI and to reaching the angstrom-scale resolution.

  19. Lung function evaluation in acute postradiation pneumonitis

    International Nuclear Information System (INIS)

    Jassem, E.; Zandwijk, N. van; Jassem, J.; Badzio, A.

    1997-01-01

    The aim of this study was pulmonary function evaluation in patients with radiation pneumonitis (rp). Study group included 18 patients with symptomatic rp (8 with breast cancer, 6 with Hodgkin's disease and 4 with lung cancer) treated at the Netherland s Cancer inst. In Amsterdam between 1988 and 1994. The lung function tests were performed at the time of rp presentation and monthly thereafter and consisted of a standard spirometry: forced expiratory volume in 1 sec. (FEV1), vital capacity (VC) and diffusing capacity for carbon monoxide (DLCO) performed with the use of a single breath technique. The mean values of DLCO, VC, FEV1 and TLC at the time of rp presentation were 72.2%, 91.0% and 85.8% of predicted value (pv), respectively. The results of the a bone tests at the last examination (66.4%, 85.6%, 77.2% and 76.2% of pv), respectively, were lower than those registered at the time of rp presentation. The highest degree of functional deterioration included diffusion capacity; the mean of the lowest values of DLCO was 56.4% of pv. Usually the lowest value of DLCO accompanied the exacerbation of clinical symptoms. The results of this study demonstrated pulmonary function deterioration in patients with rp. (author)

  20. Evaluation value of coronary CTA for coronary plaque features and its correlation with platelet function and serum biochemical indexes

    Directory of Open Access Journals (Sweden)

    Jin-Xia Yang

    2017-01-01

    Full Text Available Objective: To analyze the evaluation value of coronary CT angiography for coronary plaque features and its correlation with platelet function and serum biochemical indexes. Methods: A total of 450 patients with coronary heart disease were divided into calcified plaque group (CT value≥130HU (n=117, soft plaque group (CT value≤60HU (n=150 and mixed plaque group (CT value 60-130HU (n=183 by coronary CT angiography (CTA, and 100 healthy subjects who received physical examination in our hospital during the same period were selected as control group. Differences in platelet function and serum biochemical indexes were compared among four groups of patients, and the judgment value of atheromatous plaque CT value from CTA for the severity of coronary heart disease was analyzed. Results: Platelet function parameters MPV, TEG-MA, P-selectin, PDGF-BB and vWF levels in peripheral blood of soft plaque group were higher than those of the other three groups; inflammatory factors CRP, IL-6, IL-12, IL-18 and IL-23 content in serum were higher than those of the other three groups; chemokines MCP-1, CXCL16, Fractalkine and RANTES content in serum were higher than those of the other three groups; adipocytokines Leptin and RBP4 content in serum were higher than those of the other three groups while SFRP5 content was lower than those of the other three groups. Atheromatous plaque CT value in patients with coronary heart disease was directly correlated with platelet function and the content of serum biochemical indexes. Conclusions: Coronary CTA can accurately assess coronary atheromatous plaque features, and can also be a reliable noninvasive method to judge coronary heart disease severity, treatment prognosis and so on.

  1. Improved Steganographic Method Preserving Pixel-Value Differencing Histogram with Modulus Function

    Directory of Open Access Journals (Sweden)

    Lee Hae-Yeoun

    2010-01-01

    Full Text Available Abstract We herein advance a secure steganographic algorithm that uses a turnover policy and a novel adjusting process. Although the method of Wang et al. uses Pixel-Value Differencing (PVD and their modulus function provides high capacity and good image quality, the embedding process causes a number of artifacts, such as abnormal increases and fluctuations in the PVD histogram, which may reveal the existence of the hidden message. In order to enhance the security of the algorithm, a turnover policy is used that prevents abnormal increases in the histogram values and a novel adjusting process is devised to remove the fluctuations at the border of the subrange in the PVD histogram. The proposed method therefore eliminates all the weaknesses of the PVD steganographic methods thus far proposed and guarantees secure communication. In the experiments described herein, the proposed algorithm is compared with other PVD steganographic algorithms by using well-known steganalysis techniques, such as RS-analysis, steganalysis for LSB matching, and histogram-based attacks. The results support our contention that the proposed method enhances security by keeping the PVD histogram similar to the cover, while also providing high embedding capacity and good imperceptibility to the naked eye.

  2. Tunable catalytic properties of bi-functional mixed oxides in ethanol conversion to high value compounds

    Energy Technology Data Exchange (ETDEWEB)

    Ramasamy, Karthikeyan K.; Gray, Michel J.; Job, Heather M.; Smith, Colin D.; Wang, Yong

    2016-04-10

    tA highly versatile ethanol conversion process to selectively generate high value compounds is pre-sented here. By changing the reaction temperature, ethanol can be selectively converted to >C2alcohols/oxygenates or phenolic compounds over hydrotalcite derived bi-functional MgO–Al2O3cata-lyst via complex cascade mechanism. Reaction temperature plays a role in whether aldol condensationor the acetone formation is the path taken in changing the product composition. This article containsthe catalytic activity comparison between the mono-functional and physical mixture counterpart to thehydrotalcite derived mixed oxides and the detailed discussion on the reaction mechanisms.

  3. A single hidden layer feedforward network with only one neuron in the hidden layer can approximate any univariate function

    OpenAIRE

    Guliyev , Namig; Ismailov , Vugar

    2016-01-01

    The possibility of approximating a continuous function on a compact subset of the real line by a feedforward single hidden layer neural network with a sigmoidal activation function has been studied in many papers. Such networks can approximate an arbitrary continuous function provided that an unlimited number of neurons in a hidden layer is permitted. In this paper, we consider constructive approximation on any finite interval of $\\mathbb{R}$ by neural networks with only one neuron in the hid...

  4. Dependence on liquid temperature and purity of light emission characteristics in single cavitation bubble luminescence

    Energy Technology Data Exchange (ETDEWEB)

    Barbaglia, Mario O; Bonetto, Fabian J [Consejo Nacional de Investigaciones Cientificas y Tecnicas and Instituto Balseiro, Centro Atomico Bariloche, Av. Bustillo 9500, CP8400, Rio Negro (Argentina); Consejo Nacional de Investigaciones Cientificas y Tecnicas, Instituto Balseiro, and Comision Nacional de Energia Atomica, Laboratorio de Cavitacion y Biotecnologia, Centro Atomico Bariloche, Av. Bustillo 9500, CP8400, Rio Negro (Argentina)

    2004-02-15

    We produced single bubbles in water using a visible pulsed laser and studied the characteristics of the light emitted during the bubble collapse time as a function of the water temperature for different water purity values. The water temperature ranged from freezing point (0 deg. C) to near boiling. We measured the luminescence pulse for the mentioned temperature range at various purity values. We also obtained the average bubble lifetime and the average luminescence pulse emitted as a function of water temperature. The main conclusion was that the luminescence can be modified by the water quality and by the water temperature. Maximum luminescence was obtained near the water freezing point.

  5. Dependence on liquid temperature and purity of light emission characteristics in single cavitation bubble luminescence

    International Nuclear Information System (INIS)

    Barbaglia, Mario O.; Bonetto, Fabian J.

    2004-01-01

    We produced single bubbles in water using a visible pulsed laser and studied the characteristics of the light emitted during the bubble collapse time as a function of the water temperature for different water purity values. The water temperature ranged from freezing point (0 deg. C) to near boiling. We measured the luminescence pulse for the mentioned temperature range at various purity values. We also obtained the average bubble lifetime and the average luminescence pulse emitted as a function of water temperature. The main conclusion was that the luminescence can be modified by the water quality and by the water temperature. Maximum luminescence was obtained near the water freezing point

  6. Organic photovoltaic devices with a single layer geometry (Conference Presentation)

    Science.gov (United States)

    Kolesov, Vladimir A.; Fuentes-Hernandez, Canek; Aizawa, Naoya; Larrain, Felipe A.; Chou, Wen-Fang; Perrotta, Alberto; Graham, Samuel; Kippelen, Bernard

    2016-09-01

    Organic photovoltaics (OPV) can lead to a low cost and short energy payback time alternative to existing photovoltaic technologies. However, to fulfill this promise, power conversion efficiencies must be improved and simultaneously the architecture of the devices and their processing steps need to be further simplified. In the most efficient devices to date, the functions of photocurrent generation, and hole/electron collection are achieved in different layers adding complexity to the device fabrication. In this talk, we present a novel approach that yields devices in which all these functions are combined in a single layer. Specifically, we report on bulk heterojunction devices in which amine-containing polymers are first mixed in the solution together with the donor and acceptor materials that form the active layer. A single-layer coating yields a self-forming bottom electron-collection layer comprised of the amine-containing polymer (e.g. PEIE). Hole-collection is achieved by subsequent immersion of this single layer in a solution of a polyoxometalate (e.g. phosphomolybdic acid (PMA)) leading to an electrically p-doped region formed by the diffusion of the dopant molecules into the bulk. The depth of this doped region can be controlled with values up to tens of nm by varying the immersion time. Devices with a single 500 nm-thick active layer of P3HT:ICBA processed using this method yield power conversion efficiency (PCE) values of 4.8 ± 0.3% at 1 sun and demonstrate a performance level superior to that of benchmark three-layer devices with separate layers of PEIE/P3HT:ICBA/MoOx (4.1 ± 0.4%). Devices remain stable after shelf lifetime experiments carried-out at 60 °C over 280 h.

  7. Single-sided NMR

    CERN Document Server

    Casanova, Federico; Blümich, Bernhard

    2011-01-01

    Single-Sided NMR describes the design of the first functioning single-sided tomograph, the related measurement methods, and a number of applications. One of the key advantages to this method is the speed at which the images are obtained.

  8. The reliability of a single protocol to determine endothelial, microvascular and autonomic functions in adolescents.

    Science.gov (United States)

    Bond, Bert; Williams, Craig A; Barker, Alan R

    2017-11-01

    Impairments in macrovascular, microvascular and autonomic function are present in asymptomatic youths with clustered cardiovascular disease risk factors. This study determines the within-day reliability and between-day reliability of a single protocol to non-invasively assess these outcomes in adolescents. Forty 12- to 15-year-old adolescents (20 boys) visited the laboratory in a fasted state on two occasions, approximately 1 week apart. One hour after a standardized cereal breakfast, macrovascular function was determined via flow-mediated dilation (FMD). Heart rate variability (root mean square of successive R-R intervals; RMSSD) was determined from the ECG-gated ultrasound images acquired during the FMD protocol prior to cuff occlusion. Microvascular function was simultaneously quantified as the peak (PRH) and total (TRH) hyperaemic response to occlusion in the cutaneous circulation of the forearm via laser Doppler imaging. To address within-day reliability, a subset of twenty adolescents (10 boys) repeated these measures 90 min afterwards on one occasion. The within-day typical error and between-day typical error expressed as a coefficient of variation of these outcomes are as follows: ratio-scaled FMD, 5·1% and 10·6%; allometrically scaled FMD, 4·4% and 9·4%; PRH, 11% and 13·3%; TRH, 29·9% and 23·1%; and RMSSD, 17·6% and 17·6%. The within- and between-day test-retest correlation coefficients for these outcomes were all significant (r > 0·54 for all). Macrovascular, microvascular and autonomic functions can be simultaneously and non-invasively determined in adolescents using a single protocol with an appropriate degree of reproducibility. Determining these outcomes may provide greater understanding of the progression of cardiovascular disease and aid early intervention. © 2016 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley & Sons Ltd.

  9. Scintigraphy at 3 months after single lung transplantation and observations of primary graft dysfunction and lung function

    DEFF Research Database (Denmark)

    Belmaati, Esther Okeke; Iversen, Martin; Kofoed, Klaus F

    2012-01-01

    procedure 3 months after single lung transplantation (SLTX). A total of 41 patients were included in the study: 20 women and 21 men with the age span of patients at transplantation being 38-66 years (mean ± SD: 54.2 ± 6.0). Patient records also included lung function tests and chest X-ray images. We found......Scintigraphy has been used as a tool to detect dysfunction of the lung before and after transplantation. The aims of this study were to evaluate the development of the ventilation-perfusion relationships in single lung transplant recipients in the first year, at 3 months after transplantation...

  10. The effects of video modeling in teaching functional living skills to persons with ASD: A meta-analysis of single-case studies.

    Science.gov (United States)

    Hong, Ee Rea; Ganz, Jennifer B; Mason, Rose; Morin, Kristi; Davis, John L; Ninci, Jennifer; Neely, Leslie C; Boles, Margot B; Gilliland, Whitney D

    2016-10-01

    Many individuals with autism spectrum disorders (ASD) show deficits in functional living skills, leading to low independence, limited community involvement, and poor quality of life. With development of mobile devices, utilizing video modeling has become more feasible for educators to promote functional living skills of individuals with ASD. This article aims to review the single-case experimental literature and aggregate results across studies involving the use of video modeling to improve functional living skills of individuals with ASD. The authors extracted data from single-case experimental studies and evaluated them using the Tau-U effect size measure. Effects were also differentiated by categories of potential moderators and other variables, including age of participants, concomitant diagnoses, types of video modeling, and outcome measures. Results indicate that video modeling interventions are overall moderately effective with this population and dependent measures. While significant differences were not found between categories of moderators and other variables, effects were found to be at least moderate for most of them. It is apparent that more single-case experiments are needed in this area, particularly with preschool and secondary-school aged participants, participants with ASD-only and those with high-functioning ASD, and for video modeling interventions addressing community access skills. Copyright © 2016 Elsevier Ltd. All rights reserved.

  11. Functional enrichment analyses and construction of functional similarity networks with high confidence function prediction by PFP

    Directory of Open Access Journals (Sweden)

    Kihara Daisuke

    2010-05-01

    Full Text Available Abstract Background A new paradigm of biological investigation takes advantage of technologies that produce large high throughput datasets, including genome sequences, interactions of proteins, and gene expression. The ability of biologists to analyze and interpret such data relies on functional annotation of the included proteins, but even in highly characterized organisms many proteins can lack the functional evidence necessary to infer their biological relevance. Results Here we have applied high confidence function predictions from our automated prediction system, PFP, to three genome sequences, Escherichia coli, Saccharomyces cerevisiae, and Plasmodium falciparum (malaria. The number of annotated genes is increased by PFP to over 90% for all of the genomes. Using the large coverage of the function annotation, we introduced the functional similarity networks which represent the functional space of the proteomes. Four different functional similarity networks are constructed for each proteome, one each by considering similarity in a single Gene Ontology (GO category, i.e. Biological Process, Cellular Component, and Molecular Function, and another one by considering overall similarity with the funSim score. The functional similarity networks are shown to have higher modularity than the protein-protein interaction network. Moreover, the funSim score network is distinct from the single GO-score networks by showing a higher clustering degree exponent value and thus has a higher tendency to be hierarchical. In addition, examining function assignments to the protein-protein interaction network and local regions of genomes has identified numerous cases where subnetworks or local regions have functionally coherent proteins. These results will help interpreting interactions of proteins and gene orders in a genome. Several examples of both analyses are highlighted. Conclusion The analyses demonstrate that applying high confidence predictions from PFP

  12. Value management : functional expression of the need and functional performance specification : requirements for expressing and validating the need to be satisfied within the process of purchasing or obtaining a product

    CERN Document Server

    Association Française de Normalisation. Paris

    2013-01-01

    Value management : functional expression of the need and functional performance specification : requirements for expressing and validating the need to be satisfied within the process of purchasing or obtaining a product

  13. Reference absolute and indexed values for left and right ventricular volume, function and mass from cardiac computed tomography

    International Nuclear Information System (INIS)

    Stojanovska, Jadranka; Prasitdumrong, Hutsaya; Patel, Smita; Sundaram, Baskaran; Gross, Barry H.; Yilmaz, Zeynep N.; Kazerooni, Ella A.

    2014-01-01

    Left ventricular (LV) and right ventricular (RV) volumetric and functional parameters are important biomarkers for morbidity and mortality in patients with heart failure. To retrospectively determine reference mean values of LV and RV volume, function and mass normalised by age, gender and body surface area (BSA) from retrospectively electrocardiographically gated 64-slice cardiac computed tomography (CCT) by using automated analysis software in healthy adults. The study was approved by the institutional review board with a waiver of informed consent. Seventy-four healthy subjects (49% female, mean age 49.6±11) free of hypertension and hypercholesterolaemia with a normal CCT formed the study population. Analyses of LV and RV volume (end-diastolic, end-systolic and stroke volumes), function (ejection fraction), LV mass and inter-rater reproducibility were performed with commercially available analysis software capable of automated contour detection. General linear model analysis was performed to assess statistical significance by age group after adjustment for gender and BSA. Bland–Altman analysis assessed the inter-rater agreement. The reference range for LV and RV volume, function, and LV mass was normalised to age, gender and BSA. Statistically significant differences were noted between genders in both LV mass and RV volume (P-value<0.0001). Age, in concert with gender, was associated with significant differences in RV end-diastolic volume and LV ejection fraction (P-values 0.027 and 0.03). Bland–Altman analysis showed acceptable limits of agreement (±1.5% for ejection fraction) without systematic error. LV and RV volume, function and mass normalised to age, gender and BSA can be reported from CCT datasets, providing additional information important for patient management.

  14. Application of Extreme Value Theory to Crash Data Analysis.

    Science.gov (United States)

    Xu, Lan; Nusholtz, Guy

    2017-11-01

    A parametric model obtained by fitting a set of data to a function generally uses a procedure such as maximum likelihood or least squares. In general this will generate the best estimate for the distribution of the data overall but will not necessarily generate a reasonable estimation for the tail of the distribution unless the function fitted resembles the underlying distribution function. A distribution function can represent an estimate that is significantly different from the actual tail data, while the bulk of the data is reasonably represented by the central part of the fitted distribution. Extreme value theory can be used to improve the predictive capabilities of the fitted function in the tail region. In this study the peak-over-threshold approach from the extreme value theory was utilized to show that it is possible to obtain a better fit of the tail of a distribution than the procedures that use the entire distribution only. Additional constraints, on the current use of the extreme value approach with respect to the selection of the threshold (an estimate of the beginning of the tail region) that minimize the sensitivity to individual data samples associated with the tail section as well as contamination from the central distribution are used. Once the threshold is determined, the maximum likelihood method was used to fit the exceedances with the Generalized Pareto Distribution to obtain the tail distribution. The approach was then used in the analysis of airbag inflator pressure data from tank tests, crash velocity distribution and mass distribution from the field crash data (NASS). From the examples, the extreme (tail) distributions were better estimated with the Generalized Pareto Distribution, than a single overall distribution, along with the probability of the occurrence for a given extreme value, or a rare observation such as a high speed crash. It was concluded that the peak-over-threshold approach from extreme value theory can be a useful tool in

  15. Evaluation of reserved hepatic function in patients with hepatobiliary tumor by 99mTc-GSA. Effect of hyperbilirubinemia and usefulness of regional reserved hepatic functional imaging

    International Nuclear Information System (INIS)

    Jin Wu; Ishikawa, Nobuyoshi; Takeda, Tohoru; Sato, Motohiro; Todoroki, Takeshi; Itai, Yuji; Fukunaga, Kiyoshi; Okumura, Toshiyuki; Hatakeyama, Rokurou.

    1996-01-01

    The evaluation of the reserved hepatic function was performed by 99m Tc-galactosyl serum albumin ( 99m Tc-GSA) in 70 patients with hepatobiliary tumor. The dynamic study was performed to evaluate global reserved hepatic function following the intravenous bolus injection of 99m Tc-GSA, and the hepatic single photon emission computed tomography (SPECT) was obtained to assess the regional reserved hepatic function. The functional hepatic index (LHL 15 ) was derived from liver time-activity data, and it was compared with serum total-bilirubin level, serum albumin level and plasma disappearance rate of indocyanine green (ICG 15 ). In the patients with hepatocellular carcinoma, LHL 15 value agreed well with ICG 15 value, serum total-bilirubin level, and serum albumin level. Moderate or severe hepatic dysfunction was observed at 65.4% of these patients. In the patients with cholangiocellular carcinoma, a discrepancy of LHL 15 value and ICG 15 value was observed. Increment of the ICG 15 value was correlated with that of the serum total-bilirubin level, whereas the correlation was not observed between the LHL 15 value and the serum total-bilirubin level. These results indicate that 99m Tc-GSA scintigraphy can evaluate the reserved hepatic function without the embellishment of jaundice. This method is useful for assessing the global and regional reserved hepatic function. (author)

  16. Value-based assessment of robotic pancreas and liver surgery.

    Science.gov (United States)

    Patti, James C; Ore, Ana Sofia; Barrows, Courtney; Velanovich, Vic; Moser, A James

    2017-08-01

    Current healthcare economic evaluations are based only on the perspective of a single stakeholder to the healthcare delivery process. A true value-based decision incorporates all of the outcomes that could be impacted by a single episode of surgical care. We define the value proposition for robotic surgery using a stakeholder model incorporating the interests of all groups participating in the provision of healthcare services: patients, surgeons, hospitals and payers. One of the developing and expanding fields that could benefit the most from a complete value-based analysis is robotic hepatopancreaticobiliary (HPB) surgery. While initial robot purchasing costs are high, the benefits over laparoscopic surgery are considerable. Performing a literature search we found a total of 18 economic evaluations for robotic HPB surgery. We found a lack of evaluations that were carried out from a perspective that incorporates all of the impacts of a single episode of surgical care and that included a comprehensive hospital cost assessment. For distal pancreatectomies, the two most thorough examinations came to conflicting results regarding total cost savings compared to laparoscopic approaches. The most thorough pancreaticoduodenectomy evaluation found non-significant savings for total hospital costs. Robotic hepatectomies showed no cost savings over laparoscopic and only modest savings over open techniques. Lastly, robotic cholecystectomies were found to be more expensive than the gold-standard laparoscopic approach. Existing cost accounting data associated with robotic HPB surgery is incomplete and unlikely to reflect the state of this field in the future. Current data combines the learning curves for new surgical procedures being undertaken by HPB surgeons with costs derived from a market dominated by a single supplier of robotic instruments. As a result, the value proposition for stakeholders in this process cannot be defined. In order to solve this problem, future studies

  17. Single bumps in a 2-population homogenized neuronal network model

    Science.gov (United States)

    Kolodina, Karina; Oleynik, Anna; Wyller, John

    2018-05-01

    We investigate existence and stability of single bumps in a homogenized 2-population neural field model, when the firing rate functions are given by the Heaviside function. The model is derived by means of the two-scale convergence technique of Nguetseng in the case of periodic microvariation in the connectivity functions. The connectivity functions are periodically modulated in both the synaptic footprint and in the spatial scale. The bump solutions are constructed by using a pinning function technique for the case where the solutions are independent of the local variable. In the weakly modulated case the generic picture consists of two bumps (one narrow and one broad bump) for each admissible set of threshold values for firing. In addition, a new threshold value regime for existence of bumps is detected. Beyond the weakly modulated regime the number of bumps depends sensitively on the degree of heterogeneity. For the latter case we present a configuration consisting of three coexisting bumps. The linear stability of the bumps is studied by means of the spectral properties of a Fredholm integral operator, block diagonalization of this operator and the Fourier decomposition method. In the weakly modulated regime, one of the bumps is unstable for all relative inhibition times, while the other one is stable for small and moderate values of this parameter. The latter bump becomes unstable as the relative inhibition time exceeds a certain threshold. In the case of the three coexisting bumps detected in the regime of finite degree of heterogeneity, we have at least one stable bump (and maximum two stable bumps) for small and moderate values of the relative inhibition time.

  18. Determination of the displacement cross section in single-walled carbon nanotubes under gamma irradiation

    International Nuclear Information System (INIS)

    Leyva, A.; Pinnera, I.; Cruz, C.; Abreu, Y.; Leyva, D.

    2009-01-01

    Using the threshold energy value reported in literature for C atoms in single-walled carbon nanotube and taking into account the McKinley-Feshbach approach, the effective atomic displacement cross-section in nanotubes exposed to the gamma rays was estimated. In this calculation the Kinchin-Pease approximation for the damage function was considered. (Author)

  19. Predictive value of different conventional and non-conventional MRI-parameters for specific domains of cognitive function in multiple sclerosis

    Directory of Open Access Journals (Sweden)

    Daniela Pinter

    2015-01-01

    Conclusions: The predictive value of distinct MRI-parameters differs for specific domains of cognitive function, with a greater impact of cortical volume, focal and diffuse white matter abnormalities on overall cognitive function, an additional role of basal ganglia iron deposition on cognitive efficiency, and thalamic and hippocampal volume on memory function. This suggests the usefulness of using multiparametric MRI to assess (microstructural correlates of different cognitive constructs.

  20. Spatial and Single-Cell Transcriptional Profiling Identifies Functionally Distinct Human Dermal Fibroblast Subpopulations.

    Science.gov (United States)

    Philippeos, Christina; Telerman, Stephanie B; Oulès, Bénédicte; Pisco, Angela O; Shaw, Tanya J; Elgueta, Raul; Lombardi, Giovanna; Driskell, Ryan R; Soldin, Mark; Lynch, Magnus D; Watt, Fiona M

    2018-04-01

    Previous studies have shown that mouse dermis is composed of functionally distinct fibroblast lineages. To explore the extent of fibroblast heterogeneity in human skin, we used a combination of comparative spatial transcriptional profiling of human and mouse dermis and single-cell transcriptional profiling of human dermal fibroblasts. We show that there are at least four distinct fibroblast populations in adult human skin, not all of which are spatially segregated. We define markers permitting their isolation and show that although marker expression is lost in culture, different fibroblast subpopulations retain distinct functionality in terms of Wnt signaling, responsiveness to IFN-γ, and ability to support human epidermal reconstitution when introduced into decellularized dermis. These findings suggest that ex vivo expansion or in vivo ablation of specific fibroblast subpopulations may have therapeutic applications in wound healing and diseases characterized by excessive fibrosis. Copyright © 2018 The Authors. Published by Elsevier Inc. All rights reserved.

  1. The Effects of Single and Close Binary Evolution on the Stellar Mass Function

    Science.gov (United States)

    Schneider, R. N. F.; Izzard, G. R.; de Mink, S.; Langer, N., Stolte, A., de Koter, A.; Gvaramadze, V. V.; Hussmann, B.; Liermann, A.; Sana, H.

    2013-06-01

    Massive stars are almost exclusively born in star clusters, where stars in a cluster are expected to be born quasi-simultaneously and with the same chemical composition. The distribution of their birth masses favors lower over higher stellar masses, such that the most massive stars are rare, and the existence of an stellar upper mass limit is still debated. The majority of massive stars are born as members of close binary systems and most of them will exchange mass with a close companion during their lifetime. We explore the influence of single and binary star evolution on the high mass end of the stellar mass function using a rapid binary evolution code. We apply our results to two massive Galactic star clusters and show how the shape of their mass functions can be used to determine cluster ages and comment on the stellar upper mass limit in view of our new findings.

  2. Horizon wave function for single localized particles: GUP and quantum black-hole decay

    International Nuclear Information System (INIS)

    Casadio, Roberto; Scardigli, Fabio

    2014-01-01

    A localized particle in Quantum Mechanics is described by a wave packet in position space, regardless of its energy. However, from the point of view of General Relativity, if the particle's energy density exceeds a certain threshold, it should be a black hole. To combine these two pictures, we introduce a horizon wave function determined by the particle wave function in position space, which eventually yields the probability that the particle is a black hole. The existence of a minimum mass for black holes naturally follows, albeit not in the form of a sharp value around the Planck scale, but rather like a vanishing probability that a particle much lighter than the Planck mass may be a black hole. We also show that our construction entails an effective generalized uncertainty principle (GUP), simply obtained by adding the uncertainties coming from the two wave functions associated with a particle. Finally, the decay of microscopic (quantum) black holes is also described in agreement with what the GUP predicts. (orig.)

  3. Weak Convergence and Banach Space-Valued Functions: Improving the Stability Theory of Feynman’s Operational Calculi

    International Nuclear Information System (INIS)

    Nielsen, Lance

    2011-01-01

    In this paper we investigate the relation between weak convergence of a sequence {μ n } of probability measures on a Polish space S converging weakly to the probability measure μ and continuous, norm-bounded functions into a Banach space X. We show that, given a norm-bounded continuous function f:S→X, it follows that lim n∞ ∫ S f, dμ n = ∫ S f, dμ —the limit one has for bounded and continuous real (or complex)—valued functions on S. This result is then applied to the stability theory of Feynman’s operational calculus where it is shown that the theory can be significantly improved over previous results.

  4. Simulating real world functioning in schizophrenia using a naturalistic city environment and single-trial, goal-directed navigation

    Directory of Open Access Journals (Sweden)

    John A Zawadzki

    2013-11-01

    Full Text Available Objective: To develop a virtual reality platform that would serve as a functionally meaningful measure of cognition in schizophrenia that would complement standard batteries of cognitive tests during clinical trials for cognitive treatments in schizophrenia, be amenable to human neuroimaging research, yet lend itself to neurobiological comparison with rodent analogues.Method: Thirty-three patients with schizophrenia and 33 healthy controls matched for age, sex, video gaming experience and education completed eight rapid, single-trial virtual navigation tasks within a naturalistic virtual city. Four trials tested their ability to find different targets seen during the passive viewing of a closed path that led them around different city blocks. Four subsequent trials tested their ability to return to four different starting points after viewing a path that took them several blocks away from the starting position. Results: Individuals with schizophrenia had difficulties in way-finding, measured as distance travelled to find targets previously encountered within the virtual city. They were also more likely not to notice the target during passive viewing, less likely to find novel shortcuts to targets and more likely to become lost and fail completely in finding the target. Total travel distances across all eight trials strongly correlated (negatively with neurocognitive measures and, for 49 participants who completed the Quality of Life Scale, psychosocial functioning. Conclusion: Single-trial, goal-directed navigation in a naturalistic virtual environment is a functionally meaningful measure of cognitive functioning in schizophrenia.

  5. Highly mesoporous single-crystalline zeolite beta synthesized using a nonsurfactant cationic polymer as a dual-function template

    KAUST Repository

    Zhu, Jie

    2014-02-12

    Mesoporous zeolites are useful solid catalysts for conversion of bulky molecules because they offer fast mass transfer along with size and shape selectivity. We report here the successful synthesis of mesoporous aluminosilicate zeolite Beta from a commercial cationic polymer that acts as a dual-function template to generate zeolitic micropores and mesopores simultaneously. This is the first demonstration of a single nonsurfactant polymer acting as such a template. Using high-resolution electron microscopy and tomography, we discovered that the resulting material (Beta-MS) has abundant and highly interconnected mesopores. More importantly, we demonstrated using a three-dimensional electron diffraction technique that each Beta-MS particle is a single crystal, whereas most previously reported mesoporous zeolites are comprised of nanosized zeolitic grains with random orientations. The use of nonsurfactant templates is essential to gaining single-crystalline mesoporous zeolites. The single-crystalline nature endows Beta-MS with better hydrothermal stability compared with surfactant-derived mesoporous zeolite Beta. Beta-MS also exhibited remarkably higher catalytic activity than did conventional zeolite Beta in acid-catalyzed reactions involving large molecules. © 2014 American Chemical Society.

  6. Visual function after implantation of single-piece toric hydrophilic acrylic intraocular lenses with hydrophobic surface six months after cataract surgery

    Directory of Open Access Journals (Sweden)

    Alja Črnej

    2012-06-01

    Conclusion: Patients with medium to high corneal astigmatism and implanted single-piece toric hydrophilic acrylic IOLs with hydrophobic surface have very good visual function six months postoperatively.

  7. Examining the reinforcing value of stimuli within social and non-social contexts in children with and without high-functioning autism.

    Science.gov (United States)

    Goldberg, Melissa C; Allman, Melissa J; Hagopian, Louis P; Triggs, Mandy M; Frank-Crawford, Michelle A; Mostofsky, Stewart H; Denckla, Martha B; DeLeon, Iser G

    2017-10-01

    One of the key diagnostic criteria for autism spectrum disorder includes impairments in social interactions. This study compared the extent to which boys with high-functioning autism and typically developing boys "value" engaging in activities with a parent or alone. Two different assessments that can empirically determine the relative reinforcing value of social and non-social stimuli were employed: paired-choice preference assessments and progressive-ratio schedules. There were no significant differences between boys with high-functioning autism and typically developing boys on either measure. Moreover, there was a strong correspondence in performance across these two measures for participants in each group. These results suggest that the relative reinforcing value of engaging in activities with a primary caregiver is not diminished for children with autism spectrum disorder.

  8. Single field double inflation and primordial black holes

    Energy Technology Data Exchange (ETDEWEB)

    Kannike, K.; Marzola, L.; Raidal, M.; Veermäe, H., E-mail: kristjan.kannike@cern.ch, E-mail: luca.marzola@cern.ch, E-mail: martti.raidal@cern.ch, E-mail: hardi.veermae@cern.ch [National Institute of Chemical Physics and Biophysics, Rävala 10, 10143 Tallinn (Estonia)

    2017-09-01

    Within the framework of scalar-tensor theories, we study the conditions that allow single field inflation dynamics on small cosmological scales to significantly differ from that of the large scales probed by the observations of cosmic microwave background. The resulting single field double inflation scenario is characterised by two consequent inflation eras, usually separated by a period where the slow-roll approximation fails. At large field values the dynamics of the inflaton is dominated by the interplay between its non-minimal coupling to gravity and the radiative corrections to the inflaton self-coupling. For small field values the potential is, instead, dominated by a polynomial that results in a hilltop inflation. Without relying on the slow-roll approximation, which is invalidated by the appearance of the intermediate stage, we propose a concrete model that matches the current measurements of inflationary observables and employs the freedom granted by the framework on small cosmological scales to give rise to a sizeable population of primordial black holes generated by large curvature fluctuations. We find that these features generally require a potential with a local minimum. We show that the associated primordial black hole mass function is only approximately lognormal.

  9. Grey-Markov prediction model based on background value optimization and central-point triangular whitenization weight function

    Science.gov (United States)

    Ye, Jing; Dang, Yaoguo; Li, Bingjun

    2018-01-01

    Grey-Markov forecasting model is a combination of grey prediction model and Markov chain which show obvious optimization effects for data sequences with characteristics of non-stationary and volatility. However, the state division process in traditional Grey-Markov forecasting model is mostly based on subjective real numbers that immediately affects the accuracy of forecasting values. To seek the solution, this paper introduces the central-point triangular whitenization weight function in state division to calculate possibilities of research values in each state which reflect preference degrees in different states in an objective way. On the other hand, background value optimization is applied in the traditional grey model to generate better fitting data. By this means, the improved Grey-Markov forecasting model is built. Finally, taking the grain production in Henan Province as an example, it verifies this model's validity by comparing with GM(1,1) based on background value optimization and the traditional Grey-Markov forecasting model.

  10. Calculation of anomalous dimension of single-particle Green function in scalar field theory with strong nonlinear interaction

    International Nuclear Information System (INIS)

    Kolesnichenko, A.V.

    1980-01-01

    An expression for the anomalous dimension of the single-particle Green function is derived in the scalar theory with the interaction Hamiltonian Hsub(int)=g(phisup(n)/n) in the limit n→infinity. It is simultaneously shown that in this model the range of essential distances is of order of nsup(-1/2)

  11. Singular value decomposition for photon-processing nuclear imaging systems and applications for reconstruction and computing null functions.

    Science.gov (United States)

    Jha, Abhinav K; Barrett, Harrison H; Frey, Eric C; Clarkson, Eric; Caucci, Luca; Kupinski, Matthew A

    2015-09-21

    Recent advances in technology are enabling a new class of nuclear imaging systems consisting of detectors that use real-time maximum-likelihood (ML) methods to estimate the interaction position, deposited energy, and other attributes of each photon-interaction event and store these attributes in a list format. This class of systems, which we refer to as photon-processing (PP) nuclear imaging systems, can be described by a fundamentally different mathematical imaging operator that allows processing of the continuous-valued photon attributes on a per-photon basis. Unlike conventional photon-counting (PC) systems that bin the data into images, PP systems do not have any binning-related information loss. Mathematically, while PC systems have an infinite-dimensional null space due to dimensionality considerations, PP systems do not necessarily suffer from this issue. Therefore, PP systems have the potential to provide improved performance in comparison to PC systems. To study these advantages, we propose a framework to perform the singular-value decomposition (SVD) of the PP imaging operator. We use this framework to perform the SVD of operators that describe a general two-dimensional (2D) planar linear shift-invariant (LSIV) PP system and a hypothetical continuously rotating 2D single-photon emission computed tomography (SPECT) PP system. We then discuss two applications of the SVD framework. The first application is to decompose the object being imaged by the PP imaging system into measurement and null components. We compare these components to the measurement and null components obtained with PC systems. In the process, we also present a procedure to compute the null functions for a PC system. The second application is designing analytical reconstruction algorithms for PP systems. The proposed analytical approach exploits the fact that PP systems acquire data in a continuous domain to estimate a continuous object function. The approach is parallelizable and

  12. Singular value decomposition for photon-processing nuclear imaging systems and applications for reconstruction and computing null functions

    Science.gov (United States)

    Jha, Abhinav K.; Barrett, Harrison H.; Frey, Eric C.; Clarkson, Eric; Caucci, Luca; Kupinski, Matthew A.

    2015-09-01

    Recent advances in technology are enabling a new class of nuclear imaging systems consisting of detectors that use real-time maximum-likelihood (ML) methods to estimate the interaction position, deposited energy, and other attributes of each photon-interaction event and store these attributes in a list format. This class of systems, which we refer to as photon-processing (PP) nuclear imaging systems, can be described by a fundamentally different mathematical imaging operator that allows processing of the continuous-valued photon attributes on a per-photon basis. Unlike conventional photon-counting (PC) systems that bin the data into images, PP systems do not have any binning-related information loss. Mathematically, while PC systems have an infinite-dimensional null space due to dimensionality considerations, PP systems do not necessarily suffer from this issue. Therefore, PP systems have the potential to provide improved performance in comparison to PC systems. To study these advantages, we propose a framework to perform the singular-value decomposition (SVD) of the PP imaging operator. We use this framework to perform the SVD of operators that describe a general two-dimensional (2D) planar linear shift-invariant (LSIV) PP system and a hypothetical continuously rotating 2D single-photon emission computed tomography (SPECT) PP system. We then discuss two applications of the SVD framework. The first application is to decompose the object being imaged by the PP imaging system into measurement and null components. We compare these components to the measurement and null components obtained with PC systems. In the process, we also present a procedure to compute the null functions for a PC system. The second application is designing analytical reconstruction algorithms for PP systems. The proposed analytical approach exploits the fact that PP systems acquire data in a continuous domain to estimate a continuous object function. The approach is parallelizable and

  13. The descriptive set-theoretic complexity of the set of points of continuity of a multi-valued function (Extended Abstract

    Directory of Open Access Journals (Sweden)

    Vassilios Gregoriades

    2010-06-01

    Full Text Available In this article we treat a notion of continuity for a multi-valued function F and we compute the descriptive set-theoretic complexity of the set of all x for which F is continuous at x. We give conditions under which the latter set is either a G_delta set or the countable union of G_delta sets. Also we provide a counterexample which shows that the latter result is optimum under the same conditions. Moreover we prove that those conditions are necessary in order to obtain that the set of points of continuity of F is Borel i.e., we show that if we drop some of the previous conditions then there is a multi-valued function F whose graph is a Borel set and the set of points of continuity of F is not a Borel set. Finally we give some analogue results regarding a stronger notion of continuity for a multi-valued function. This article is motivated by a question of M. Ziegler in "Real Computation with Least Discrete Advice: A Complexity Theory of Nonuniform Computability with Applications to Linear Algebra", (submitted.

  14. The Effects of a Single Night of Sleep Deprivation on Fluency and Prefrontal Cortex Function during Divergent Thinking

    Directory of Open Access Journals (Sweden)

    Oshin eVartanian

    2014-04-01

    Full Text Available The dorsal and ventral aspects of the prefrontal cortex (PFC are the two regions most consistently recruited in divergent thinking tasks. Given that frontal tasks have been shown to be vulnerable to sleep loss, we explored the impact of a single night of sleep deprivation on fluency (i.e., number of generated responses and PFC function during divergent thinking. Participants underwent functional magnetic resonance imaging (fMRI scanning twice while engaged in the Alternate Uses Task (AUT—once following a single night of sleep deprivation and once following a night of normal sleep. They also wore wrist activity monitors, which enabled us to quantify daily sleep and model cognitive effectiveness. The intervention was effective, producing greater levels of fatigue and sleepiness. Modelled cognitive effectiveness and fluency were impaired following sleep deprivation, and sleep deprivation was associated with greater activation in the left inferior frontal gyrus during AUT. The results suggest that an intervention known to temporarily compromise frontal function can impair fluency, and that this effect is instantiated in the form of an increased haemodynamic response in the left inferior frontal gyrus.

  15. The study of the value of applying the special functions of DSA during uterine artery embolization

    International Nuclear Information System (INIS)

    Wang Ting; Zhao Zhenhua; Lv Weigong

    2007-01-01

    Objective: To study the value of applying the special functions of DSA during uterine artery embolization. Methods: 122 cases were performed uterine artery embolization, including 67 cases with traditional operation and 55 cases with applying the special functions of DSA: rotary DSA angiography, the best work position and road map technology. We recorded the correlative operative indices to compare and analyse the mean exposure time, the mean operative time, the mean dosage of contrast medium, the probability of vasospasm and injury of blood vessel during operation. Results: The mean exposure time, mean operative time and the mean dosage of contrast medium were reduced with the special functions of DSA during uterine artery embolization. There is significant difference between traditional operation and the operation applying the special functions of DSA (P<0.01). Conclusion: Applying the special functions of DSA during uterine artery embolization can reduce the operative time, operative risk and economic burden. (authors)

  16. Predictive value of plasma human chorionic gonadotropin measured 14 days after Day-2 single embryo transfer

    DEFF Research Database (Denmark)

    Løssl, Kristine; Oldenburg, Anna; Toftager, Mette

    2017-01-01

    Introduction: Prediction of pregnancy outcome after in vitro fertilization is important for patients and clinicians. Early plasma human chorionic gonadotropin (p-hCG) levels are the best known predictor of pregnancy outcome, but no studies have been restricted to single embryo transfer (SET) of Day......-2 embryos. The aim of the present study was to investigate the predictive value of p-hCG measured exactly 14 days after the most commonly used Day-2 SET on pregnancy, delivery, and perinatal outcome. Material and methods: A retrospective analysis of prospectively collected data on 466 women who had...... p-hCG measured exactly 14 days after Day-2 SET during a randomized trial including 1050 unselected women (aged 18–40 years) undergoing their first in vitro fertilization/ intracytoplasmic sperm injection treatment. Results: The p-hCG predicted clinical pregnancy [area under the curve (AUC) 0.953; 95...

  17. Response of rat spinal cord to single and fractionated doses of accelerated heavy ions

    International Nuclear Information System (INIS)

    Leith, J.L.; McDonald, M.; Powers-Risius, P.; Bliven, S.F.; Walton, R.E.; Woodruff, K.H.; Howard, J.

    1980-01-01

    The response of rat spinal cord to irradiation with accelerated heavy ions, in particular carbon and neon ions has been studied. Two different ionization regions in the modified Bragg curve for each ion have been studied for both single and fractionated exposures. We have defined the paralytic response as a function of dose and dose per fraction, and we have determined RBE and repair values. The response of rat spinal cord is both dose and LET dependent, which allows the derivation of RBE and repair values

  18. The predictive value of arterial stiffness on major adverse cardiovascular events in individuals with mildly impaired renal function

    Directory of Open Access Journals (Sweden)

    Han J

    2016-08-01

    Full Text Available Jie Han,* Xiaona Wang,* Ping Ye, Ruihua Cao, Xu Yang, Wenkai Xiao, Yun Zhang, Yongyi Bai, Hongmei Wu Department of Geriatric Cardiology, Chinese PLA General Hospital, Beijing, People’s Republic of China *These authors contributed equally to this work Objectives: Despite growing evidence that arterial stiffness has important predictive value for cardiovascular disease in patients with advanced stages of chronic kidney disease, the predictive significance of arterial stiffness in individuals with mildly impaired renal function has not been established. The aim of this study was to evaluate the predictive value of arterial stiffness on cardiovascular disease in this specific population. Materials and methods: We analyzed measurements of arterial stiffness (carotid–femoral pulse-wave velocity [cf-PWV] and the incidence of major adverse cardiovascular events (MACEs in 1,499 subjects from a 4.8-year longitudinal study. Results: A multivariate Cox proportional-hazard regression analysis showed that in individuals with normal renal function (estimated glomerular filtration rate [eGFR] ≥90 mL/min/1.73 m2, the baseline cf-PWV was not associated with occurrence of MACEs (hazard ratio 1.398, 95% confidence interval 0.748–2.613; P=0.293. In individuals with mildly impaired renal function (eGFR <90 mL/min/1.73 m2, a higher baseline cf-PWV level was associated with a higher risk of MACEs (hazard ratio 2.334, 95% confidence interval 1.082–5.036; P=0.031. Conclusion: Arterial stiffness is a moderate and independent predictive factor for MACEs in individuals with mildly impaired renal function (eGFR <90 mL/min/1.73 m2. Keywords: epidemiology, arterial stiffness, impaired renal function, predictive value, MACEs

  19. Decoding Pigeon Behavior Outcomes Using Functional Connections among Local Field Potentials.

    Science.gov (United States)

    Chen, Yan; Liu, Xinyu; Li, Shan; Wan, Hong

    2018-01-01

    Recent studies indicate that the local field potential (LFP) carries information about an animal's behavior, but issues regarding whether there are any relationships between the LFP functional networks and behavior tasks as well as whether it is possible to employ LFP network features to decode the behavioral outcome in a single trial remain unresolved. In this study, we developed a network-based method to decode the behavioral outcomes in pigeons by using the functional connectivity strength values among LFPs recorded from the nidopallium caudolaterale (NCL). In our method, the functional connectivity strengths were first computed based on the synchronization likelihood. Second, the strength values were unwrapped into row vectors and their dimensions were then reduced by principal component analysis. Finally, the behavioral outcomes in single trials were decoded using leave-one-out combined with the k -nearest neighbor method. The results showed that the LFP functional network based on the gamma-band was related to the goal-directed behavior of pigeons. Moreover, the accuracy of the network features (74 ± 8%) was significantly higher than that of the power features (61 ± 12%). The proposed method provides a powerful tool for decoding animal behavior outcomes using a neural functional network.

  20. [WTP guidance technology: a comparison of payment card, single-bounded and double-bounded dichotomous formats for evaluating non-use values of Sanjiang Plain ecotourism water resources].

    Science.gov (United States)

    Chen, Hong-Guang; Wang, Qiu-Dan; Li, Chen-Yang

    2014-09-01

    Contingent valuation method (CVM) is the most widespread method to assess resources and value of environmental goods and services. The guidance technology of willingness to pay (WTP) is an important means of CVM. Therefore, the study on the WTP guidance technology is an important approach to improve the reliability and validity of CVM. This article conducted comprehensive evaluation on non-use value of eco-tourism water resources in Sanjiang Plain by using payment card, single-bound dichotomous choice and double-bound dichotomous choice. Results showed that the socio-economic attributes were consistent with the willingness to pay in the three formats, and the tender value, age, educational level, annual income and the concern level had significant effect on the willingness to pay, while gender and job did not have significant influence. The WTP value was 112.46 yuan per capita with the payment card, 136.15 with the single-bound dichotomous choice, and 168.74 with the double-bound dichotomous choice. Comprehensive consideration of the nature of the investigation, investigation costs and statistical techniques, the result of double-bound dichotomous choice (47.86 x 10(8) yuan · a(-1)) was best in accordance with the reality, and could be used as non-use value of eco-tourism water resources in Sanjiang Plain. The format of questionnaire was very important to improve its validity, and made a great influence on the WTP.

  1. Nanoparticle-functionalized nucleic acids: A strategy for amplified electrochemical detection of some single-base mismatches

    International Nuclear Information System (INIS)

    Ahangar, Laleh Enayati; Mehrgardi, Masoud A.

    2011-01-01

    In this study, nanoparticle-functionalized nucleic acids were employed to improve the sensitivity of electrochemical DNA biosensors that make capable them to detect different types of single-base mismatches (SBMs), including thermodynamically stable ones. The present biosensor was constructed by the immobilization of platinum nanoparticles (Pt-NPs) on the surface of a carbon paste electrode (CPE) via SH-functionalized DNA. A redox probe of 2-mercapto-1-methyl imidazole (MMI), which has different electrochemical behavior on Pt-NP and CPE, was used. This behavior helps to overcome the pinhole effect in DNA hybridization biosensors. Additionally, in the present biosensor, the positioning of the redox probe under the SBM in DNA, which decreases the sensitivity of most DNA biosensors, did not contribute to the observed electrochemical signal.

  2. Nanoparticle-functionalized nucleic acids: A strategy for amplified electrochemical detection of some single-base mismatches

    Energy Technology Data Exchange (ETDEWEB)

    Ahangar, Laleh Enayati [Department of Chemistry, University of Isfahan, Isfahan 81746-73441 (Iran, Islamic Republic of); Mehrgardi, Masoud A., E-mail: m.mehrgardi@gmail.co [Department of Chemistry, University of Isfahan, Isfahan 81746-73441 (Iran, Islamic Republic of)

    2011-02-15

    In this study, nanoparticle-functionalized nucleic acids were employed to improve the sensitivity of electrochemical DNA biosensors that make capable them to detect different types of single-base mismatches (SBMs), including thermodynamically stable ones. The present biosensor was constructed by the immobilization of platinum nanoparticles (Pt-NPs) on the surface of a carbon paste electrode (CPE) via SH-functionalized DNA. A redox probe of 2-mercapto-1-methyl imidazole (MMI), which has different electrochemical behavior on Pt-NP and CPE, was used. This behavior helps to overcome the pinhole effect in DNA hybridization biosensors. Additionally, in the present biosensor, the positioning of the redox probe under the SBM in DNA, which decreases the sensitivity of most DNA biosensors, did not contribute to the observed electrochemical signal.

  3. Measuring Risk-adjusted Customer Lifetime Value and its Impact on Relationship Marketing Strategies and Shareholder Value

    OpenAIRE

    Ryals, Lynette; Knox, Simon

    2005-01-01

    The calculations which underlie efforts to balance marketing spending on customer acquisition and customer retention are usually based on either single- period customer profitability or forecasts of customer lifetime value (CLTV). This paper argues instead for risk-adjusted CLTV, which is termed the economic value (EV) of a customer, as the means for marketing to assess both customer profitability and shareholder value gains.

  4. Quantitative echocardiographic measures in the assessment of single ventricle function post-Fontan: Incorporation into routine clinical practice.

    Science.gov (United States)

    Rios, Rodrigo; Ginde, Salil; Saudek, David; Loomba, Rohit S; Stelter, Jessica; Frommelt, Peter

    2017-01-01

    Quantitative echocardiographic measurements of single ventricular (SV) function have not been incorporated into routine clinical practice. A clinical protocol, which included quantitative measurements of SV deformation (global circumferential and longitudinal strain and strain rate), standard deviation of time to peak systolic strain, myocardial performance index (MPI), dP/dT from an atrioventricular valve regurgitant jet, and superior mesenteric artery resistance index, was instituted for all patients with a history of Fontan procedure undergoing echocardiography. All measures were performed real time during clinically indicated studies and were included in clinical reports. A total of 100 consecutive patients (mean age = 11.95±6.8 years, range 17 months-31.3 years) completed the protocol between September 1, 2014 to April 29, 2015. Deformation measures were completed in 100% of the studies, MPI in 93%, dP/dT in 55%, and superior mesenteric artery Doppler in 82%. The studies were reviewed to assess for efficiency in completing the protocol. The average time for image acquisition was 27.4±8.8 (range 10-62 minutes). The average time to perform deformation measures was 10.8±5.5 minutes (range 5-35 minutes) and time from beginning of imaging to report completion was 53.4±13.7 minutes (range 27-107 minutes). There was excellent inter-observer reliability when deformation indices were blindly repeated. Patients with a single left ventricle had significantly higher circumferential strain and strain rate, longitudinal strain and strain rate, and dP/dT compared to a single right ventricle. There were no differences in quantitative indices of ventricular function between patients 10 years post-Fontan. Advanced quantitative assessment of SV function post-Fontan can be consistently and efficiently performed real time during clinically indicated echocardiograms with excellent reliability. © 2016, Wiley Periodicals, Inc.

  5. The relationship between developmental lumbar spinal stenosis and its BMD value : comparison by single energy quantitative CT

    International Nuclear Information System (INIS)

    Kim, Hak Jin; Kim, Kun Il; Song, Keun Sung

    1996-01-01

    The purpose of this study is to evaluate the relationship between developmental lumbar spinal stenosis and its BMD value by using the single energy quantitative CT(SEQCT). Eighty normal volunteers(20-60years) were selected as a control group and 28 patients with developmental lumbar spinal stenosis were selected as a disease group. The two groups were divided into a younger (20-39 years) and an older subgroup (40-60 years), and were further divided into male and female subgroups. All the cases showed no evidence of metabolic disease, fracture, herniated nucleus pulposus, degererative spondylosis, infectious disease, tumors or had no history of absolute immobilization of more than two weeks. All underwent lumbar spine CT and SEQCT. we measured bone mineral density(BMD) at the cancellous bone of L1, 2, 3 and obtained the mean and its one standard deviation, and compared the data between each sub-group of the control and the disease group using ANOVA. There was a significant low BMD value in the younger male patient subgroup compared with the control subgroup(p<0.005). Developmental lumbar spinal stenosis in a young male may be a factor of decreasing BMD of the body of the spine

  6. The relationship between developmental lumbar spinal stenosis and its BMD value : comparison by single energy quantitative CT

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hak Jin; Kim, Kun Il; Song, Keun Sung [Pusan National Univ. Hospital, Pusan (Korea, Republic of)

    1996-03-01

    The purpose of this study is to evaluate the relationship between developmental lumbar spinal stenosis and its BMD value by using the single energy quantitative CT(SEQCT). Eighty normal volunteers(20-60years) were selected as a control group and 28 patients with developmental lumbar spinal stenosis were selected as a disease group. The two groups were divided into a younger (20-39 years) and an older subgroup (40-60 years), and were further divided into male and female subgroups. All the cases showed no evidence of metabolic disease, fracture, herniated nucleus pulposus, degererative spondylosis, infectious disease, tumors or had no history of absolute immobilization of more than two weeks. All underwent lumbar spine CT and SEQCT. we measured bone mineral density(BMD) at the cancellous bone of L1, 2, 3 and obtained the mean and its one standard deviation, and compared the data between each sub-group of the control and the disease group using ANOVA. There was a significant low BMD value in the younger male patient subgroup compared with the control subgroup(p<0.005). Developmental lumbar spinal stenosis in a young male may be a factor of decreasing BMD of the body of the spine.

  7. Valuing call options on single stock futures: Does the put-call parity relationship hold in the South African derivatives market?

    Directory of Open Access Journals (Sweden)

    Biebuyck, A.

    2014-09-01

    Full Text Available Research has shown that violations of put-call parity do occur and that these violations present an investor with opportunities to profit from arbitrage deals. Mispricing may lead to significant superior returns and maximisation of shareholders’ wealth if found and acted upon in a timely manner. This study attempts to determine whether this mispricing of financial derivatives is present in the South African derivatives market. This will be achieved through the valuation of options on single stock futures using the put-call parity relationship. The theoretical fair values obtained, is compared to the actual market values over a period of three years, that is, from 2009 to 2011. The results show that arbitrage opportunities do present themselves for the chosen shares. Further research may involve more shares over a longer period to determine whether any pattern may exist which may form the basis of an arbitrage trading strategy

  8. Single-particle Glauber matrix elements

    International Nuclear Information System (INIS)

    Oset, E.; Strottman, D.

    1983-01-01

    The single-particle matrix elements of the Glauber profile function are tabulated for harmonic oscillator single-particle wave functions. The tables are presented in such a manner as to be applicable if the hadron--nucleon elementary scattering amplitude is specified by either a partial wave expansion or a Gaussian in momentum transfer squared. The table is complete through the 1 g/sub 9/2/ orbital and contains entries for the 3s/sub 1/2/ orbital for use if realistic wave functions are expanded in terms of harmonic oscillator functions

  9. FDG F18/Rest Tl 201 SPECT patterns in recent myocardial infarction. Predictive value for regional function recovery

    Energy Technology Data Exchange (ETDEWEB)

    Massardo, Teresa [Universidad de Chile, Hospital Clinico. Centro de Medicina Nuclear, Santiago (Chile); Gonzalez, Patricio; Coll, Claudia; Yovanovich, Jorge; Jofre, M Josefina; Humeres, Pamela; Sierralta, Paulina; Chamorro, Hernan; Ramirez, Alfredo; Kunstmann, Sonia; Lopez, Hector; Aramburu, Ivonne; Bru, Solange [Universidad de Chile, Santiago (Chile). Hospital Clinico. Centros de Medicina Nuclear e Cardiovascular; Clinica Santa Maria, Santiago [Chile

    2003-04-01

    Background: detecting viability is important after recent myocardial infarction (MI). SPECT FDG/Tl flow-metabolism patterns for predicting functional recovery were analyzed in this setting. Method: forty-one patients were studied (56+-12 years; 80% males) with Tl 201 at rest and FDG F 18 SPECT at a mean of 8.9 days post MI (range:1-24). All had baseline and 3 month follow-up echocardiography (Echo) and initial coronary angiography. They were submitted to primary PTCA in 12 cases, late PTCA in 15 and bypass surgery in 10 and thrombolysis was performed in 4 patients as only procedure. A total of 345 culprit artery territory segments were interpreted by 3 nuclear independent observers. Analysis included segments with or without abnormal motion. Results: FDG/Tl 201 on patient basis, had: sensitivity 91%; specificity 56%; positive predictive value 88 %; negative predictive value (NPV) 63% and accuracy 83%. The analysis of segments with abnormal contractility showed values of 67%, 69%, 44%, 85% and 68%, respectively. Reverse mismatch with FDG/Tl appears to predict viability similarly to classical mismatch; severe or moderate match was highly associated with no functional recovery (NPV 85%). Conclusion: flow-perfusion patterns are variable in recent MI. FDG/Tl 201 SPECT has acceptable accuracy for predicting functional recovery and excellent NPV to further exclude viability (author)

  10. FDG F18/Rest Tl 201 SPECT patterns in recent myocardial infarction. Predictive value for regional function recovery

    International Nuclear Information System (INIS)

    Massardo, Teresa; Gonzalez, Patricio; Coll, Claudia; Yovanovich, Jorge; Jofre, M. Josefina; Humeres, Pamela; Sierralta, Paulina; Chamorro, Hernan; Ramirez, Alfredo; Kunstmann, Sonia; Lopez, Hector; Aramburu, Ivonne; Bru, Solange; Clinica Santa Maria, Santiago

    2003-01-01

    Background: detecting viability is important after recent myocardial infarction (MI). SPECT FDG/Tl flow-metabolism patterns for predicting functional recovery were analyzed in this setting. Method: forty-one patients were studied (56+-12 years; 80% males) with Tl 201 at rest and FDG F 18 SPECT at a mean of 8.9 days post MI (range:1-24). All had baseline and 3 month follow-up echocardiography (Echo) and initial coronary angiography. They were submitted to primary PTCA in 12 cases, late PTCA in 15 and bypass surgery in 10 and thrombolysis was performed in 4 patients as only procedure. A total of 345 culprit artery territory segments were interpreted by 3 nuclear independent observers. Analysis included segments with or without abnormal motion. Results: FDG/Tl 201 on patient basis, had: sensitivity 91%; specificity 56%; positive predictive value 88 %; negative predictive value (NPV) 63% and accuracy 83%. The analysis of segments with abnormal contractility showed values of 67%, 69%, 44%, 85% and 68%, respectively. Reverse mismatch with FDG/Tl appears to predict viability similarly to classical mismatch; severe or moderate match was highly associated with no functional recovery (NPV 85%). Conclusion: flow-perfusion patterns are variable in recent MI. FDG/Tl 201 SPECT has acceptable accuracy for predicting functional recovery and excellent NPV to further exclude viability (author)

  11. Acute abdomen due to gastric volvulus: diagnostic value of a single plain radiograph

    International Nuclear Information System (INIS)

    Andiran, F.; Tanyel, F.C.; Balkanci, F.; Hicsoenmez, A.

    1995-01-01

    A 2 1/2-year-old child was admitted to hospital with acute abdominal pain and vomiting. A single large air-fluid level without additional bowel gas was seen on plain abdominal radiography. At laparotomy organoaxial volvulus of the stomach was found and partial gastric resection performed. A 'single bubble' appearance may indicate gastric volvulus. (orig.)

  12. Acute abdomen due to gastric volvulus: diagnostic value of a single plain radiograph

    Energy Technology Data Exchange (ETDEWEB)

    Andiran, F. [Dept. of Pediatric Surgery, Hacettepe Children`s Hospital, Ankara (Turkey); Tanyel, F.C. [Dept. of Pediatric Surgery, Hacettepe Children`s Hospital, Ankara (Turkey); Balkanci, F. [Dept. of Radiology, Hacettepe Children`s Hospital, Ankara (Turkey); Hicsoenmez, A. [Dept. of Pediatric Surgery, Hacettepe Children`s Hospital, Ankara (Turkey)

    1995-11-01

    A 2 1/2-year-old child was admitted to hospital with acute abdominal pain and vomiting. A single large air-fluid level without additional bowel gas was seen on plain abdominal radiography. At laparotomy organoaxial volvulus of the stomach was found and partial gastric resection performed. A `single bubble` appearance may indicate gastric volvulus. (orig.)

  13. Self-Concept of Single Women.

    Science.gov (United States)

    Gigy, Lynn L.

    1980-01-01

    Explores the self-concepts of single and married women. Single women had more psychiatric symptoms, valued personal growth and achievement, and were higher on assertion and poise. Married women were more likely to identify with kinship roles and household activities. (Author)

  14. Long-term functional, subjective and psychological results after single digit replantation.

    Science.gov (United States)

    Chen, Jing; Zhang, Ai Xian; Chen, Qing Zhong; Mu, Shuai; Tan, Jun

    2018-03-01

    The aim of this study was to analyse the long-term functional, subjective, and psychological results after single-digit replantation. Thirty cases of digital replantation (14 thumbs, 12 index fingers, 2 middle fingers, 1 ring finger, and 1 little finger) in 30 patients (7 females and 23 males) with a mean age of 44.2 years (20-65 years) were evaluated at the end of a mean follow-up time of 36 months (19-50 months). The active range of motion of joints, grip and pinch strength, cutaneous sensibility, upper-extremity functioning, and subjective satisfaction were determined using the Disability of Arm, Shoulder, and Hand (DASH) questionnaire and the Michigan Hand Outcomes questionnaire (MHQ). Psychological sequelae, including depression, anxiety, and posttraumatic stress disorder (PTSD), were assessed. A correlation analysis among variables was also performed. The mean score for the DASH questionnaire was 6.6 (range: 0-39.2). The symptom of cold intolerance occurred in 53% of the patients. Two patients were diagnosed with depression, and only one patient exhibited PTSD. The DASH score had a good statistical correlation with total grip strength, pinch grip strength, and static two-point discrimination (S-2PD) (P digit replantation are very low at long-term follow-up. Level IV, therapeutic study. Copyright © 2017 Turkish Association of Orthopaedics and Traumatology. Production and hosting by Elsevier B.V. All rights reserved.

  15. Nano-optical functionality based on local photoisomerization in photochromic single crystal

    Science.gov (United States)

    Nakagomi, Ryo; Uchiyama, Kazuharu; Kubota, Satoru; Hatano, Eri; Uchida, Kingo; Naruse, Makoto; Hori, Hirokazu

    2018-01-01

    Towards the construction of functional devices and systems using optical near-field processes, we demonstrate the multivalent features in the path-branching phenomena in a photochromic single crystal observed in optical phase change between colorless (1o) and blue-colored (1c) phases that transmits in subwavelength scale over a macroscopic spatial range associated with local mechanical distortions induced. To observe the near-field optical processes of transmission path branching, we have developed a top-to-bottom double-probe scanning near-field optical microscope capable of nanometer-scale correlation measurements by two individually position-controlled probes that face each other sandwiching the photochromic material. We have experimentally confirmed that a local near-field optical excitation applied to one side of the photochromic crystal by a probe tip resulted in characteristic structures of subwavelength scale around 100 nm or less that are observed by the other probe tip located on the opposite side. The structures are different from those resulting from far-field excitations that are quantitively evaluated by autocorrelations. The results suggest that the mechanical distortion caused by the local phase change in the photochromic crystal suppresses the phase change of the neighboring molecules. This new type of optical-near-field-induced local photoisomerization has the potential to allow the construction of functional devices with multivalent properties for natural intelligence.

  16. Experimental study on heavy-ion single event effect on nanometer DDR SRAM

    International Nuclear Information System (INIS)

    Luo Yinhong; Zhang Fengqi; Guo Hongxia; Zhou Hui; Wang Yanping; Zhang Keying

    2013-01-01

    Single event effect experimental study on 90 nm and 65 nm DDR SRAM were carried out, single event upset (SEU) cross section was discussed as a function of several parameters such as feature size, test pattern, incidence angle, supply voltage. Key influence factors and effect rule were analyzed. Feasibility of the current test method was discussed. Results indicate that, SEU cross section reduces as technologies scale down; the influence of test pattern and power supply on SEU cross section is small; tilt angle increases SEU cross section due to multiple upset increasement. The applicability of cosine tilt test method is correlative to ion species and linear energy transfer (LET) values. (authors)

  17. Exchange coupling and magnetic anisotropy of exchanged-biased quantum tunnelling single-molecule magnet Ni3Mn2 complexes using theoretical methods based on Density Functional Theory.

    Science.gov (United States)

    Gómez-Coca, Silvia; Ruiz, Eliseo

    2012-03-07

    The magnetic properties of a new family of single-molecule magnet Ni(3)Mn(2) complexes were studied using theoretical methods based on Density Functional Theory (DFT). The first part of this study is devoted to analysing the exchange coupling constants, focusing on the intramolecular as well as the intermolecular interactions. The calculated intramolecular J values were in excellent agreement with the experimental data, which show that all the couplings are ferromagnetic, leading to an S = 7 ground state. The intermolecular interactions were investigated because the two complexes studied do not show tunnelling at zero magnetic field. Usually, this exchange-biased quantum tunnelling is attributed to the presence of intermolecular interactions calculated with the help of theoretical methods. The results indicate the presence of weak intermolecular antiferromagnetic couplings that cannot explain the ferromagnetic value found experimentally for one of the systems. In the second part, the goal is to analyse magnetic anisotropy through the calculation of the zero-field splitting parameters (D and E), using DFT methods including the spin-orbit effect.

  18. The Analysis of Two-Way Functional Data Using Two-Way Regularized Singular Value Decompositions

    KAUST Repository

    Huang, Jianhua Z.

    2009-12-01

    Two-way functional data consist of a data matrix whose row and column domains are both structured, for example, temporally or spatially, as when the data are time series collected at different locations in space. We extend one-way functional principal component analysis (PCA) to two-way functional data by introducing regularization of both left and right singular vectors in the singular value decomposition (SVD) of the data matrix. We focus on a penalization approach and solve the nontrivial problem of constructing proper two-way penalties from oneway regression penalties. We introduce conditional cross-validated smoothing parameter selection whereby left-singular vectors are cross- validated conditional on right-singular vectors, and vice versa. The concept can be realized as part of an alternating optimization algorithm. In addition to the penalization approach, we briefly consider two-way regularization with basis expansion. The proposed methods are illustrated with one simulated and two real data examples. Supplemental materials available online show that several "natural" approaches to penalized SVDs are flawed and explain why so. © 2009 American Statistical Association.

  19. Prediction of A CRS Frontier Function and A Transformation Function for A CCR DEA Using EMBEDED PCA

    Directory of Open Access Journals (Sweden)

    Subhadip Sarkar

    2013-08-01

    Full Text Available Data Envelopment Analysis is a nonparametric tool for measuring the performance of a number of homogenous Decision Making Units. In this paper, Principal Component Analysis is used as an alternative tool to estimate the frontier in a Data Envelopment Analysis under the assumption of Constant Return to Scale. Apart from this, in the context of a multiple inputs and single output, a transformation function, is developed here using the Most Productive Scale Size condition stated by Starrett. This function complies with all postulates of a frontier function and is very similar to the formula given by Aigner and Chu. Moreover, it is capable of defining the threshold value for any resource.

  20. Depth dependence of the single chamber response function of the I'mRT MatriXX array in a 6 MV photon beam

    International Nuclear Information System (INIS)

    Alashrah, Saleh

    2013-01-01

    One of the factors which influence the spatial resolution of a 2D detector array is the size of the single detector, another the transport of the secondary electrons from the walls into the measuring volume. In this study, the single ion chamber dose response function of an I'mRT MatriXX array was determined by comparison between slit beam dose profiles measured with the array and with EBT2 radiochromic film in a solid water-equivalent phantom at a shallow depth of 0.5 cm and at a depth of 5 cm beyond the depth dose maximum for a 6 MV photon beam. The dose response functions were obtained using two methods, the best fit method and the deconvolution method. At the shallow depth, a Lorentz function and at 5 cm depth a Gaussian function, both with the same FWHM of 7.4 mm within limits of uncertainty, were identified as the best suited dose response functions of the 4.5 mm diameter single array chamber. These dose response functions were then tested on various dose profiles whose true shape had been determined with EBT2 film and with the IC03 ionization chamber. By convolving these with the Lorentz kernel (at shallow depth) and the Gaussian kernel (at 5 cm depth) the signal profiles measured with the I'mRT MatriXX array were closely approximated. Thus, the convolution of TPS-calculated dose profiles with these dose response functions can minimize the differences between calculation and measurement which occur due to the limited spatial resolution of the I'mRT MatriXX detector. (orig.)