WorldWideScience

Sample records for single test session

  1. Aerobic and Anaerobic Swimming Force Evaluation in One Single Test Session for Young Swimmers.

    Science.gov (United States)

    de Barros Sousa, Filipe Antônio; Rodrigues, Natalia Almeida; Messias, Leonardo Henrique Dalcheco; Queiroz, Jair Borges; Manchado-Gobatto, Fulvia Barros; Gobatto, Claudio Alexandre

    2017-05-01

    This study aims to propose and validate the tethered swimming lactate minimum test (TSLacmin) estimating aerobic and anaerobic capacity in one single test session, using force as measurement parameter. 6 male and 6 female young swimmers (age=15.7±1.1 years; height=173.3±9.5 cm; weight=66.1±9.5 kg) performed 4 sessions comprising i) an all-out 30 s test and incremental test (TSLacmin); ii) 30 min of tethered swimming at constant intensity (2 sessions); iii) free-swimming time trials used to calculate critical velocity. Tethered swimming sessions used an acquisition system enabling maximum (Fmax) and mean (Fmean) force measurement and intensity variation. The tethered all-out test lasting 30 s resulted in hyperlactatemia of 7.9±2.0 mmol·l -1 . TSLacmin presented a 100% success applicability rate, which is equivalent to aerobic capacity in 75% of cases. TSLacmin intensity was 37.7±7.3 N, while maximum force in the all-out test was 105±27 N. Aerobic and anaerobic TSLacmin parameters were significantly related to free-swimming performance (r=-0.67 for 100 m and r=-0.80 for 200 m) and critical velocity (r=0.80). TSLacmin estimates aerobic capacity in most cases, and both aerobic and anaerobic force parameters are well related to critical velocity and free swimming performance. © Georg Thieme Verlag KG Stuttgart · New York.

  2. Approach avoidance training in the eating domain: testing the effectiveness across three single session studies.

    Science.gov (United States)

    Becker, Daniela; Jostmann, Nils B; Wiers, Reinout W; Holland, Rob W

    2015-02-01

    Dual-process models propose that impulsive behavior plays a key role in the development and maintenance of maladaptive eating patterns. Research outside the eating domain suggests that approach avoidance training, a paradigm which aims to modify automatic behavioral dispositions toward critical stimuli, is an effective tool to weaken unhealthy impulses. The present research tested the effectiveness of approach avoidance training in the eating domain. We conducted three single session studies with varying methodologies in a normal-weight female student population (total N = 258), in which one group was always trained to avoid pictures of unhealthy food and to approach pictures of healthy food or neutral objects. We found no conclusive evidence that approach avoidance training can change participants' implicit and explicit food preferences and eating behavior. We discuss the potential and the limitations of approach avoidance training in the eating domain and provide suggestions for future research avenues. Copyright © 2014 Elsevier Ltd. All rights reserved.

  3. BILATERAL SINGLE SESSION URETEROSCOPY FOR URETERAL ...

    African Journals Online (AJOL)

    Objectives: To determine the feasibility, safety and success rate of bilateral single session rigid retrograde ureteroscopy (URS) for bilateral ureteral calculi. Patients and Methods: Thirty-five patients underwent bilateral single session ureteroscopic calculus removal. Results: Out of 70 renal units in 35 patients treated, ...

  4. Single-Session Radiofrequency Ablation of Bilateral Lung Metastases

    International Nuclear Information System (INIS)

    Palussière, Jean; Gómez, Fernando; Cannella, Matthieu; Ferron, Stéphane; Descat, Edouard; Fonck, Marianne; Brouste, Véronique; Avril, Antoine

    2012-01-01

    Purpose: This retrospective study examined the feasibility and efficacy of bilateral lung radiofrequency ablation (RFA) performed in a single session. Methods: From 2002–2009, patients with bilateral lung metastases were treated by RFA, where possible in a single session under general anesthesia with CT guidance. The second lung was punctured only if no complications occurred after treatment of the first lung. Five lung metastases maximum per patient were treated by RFA and prospectively followed. The primary endpoint was the evaluation of acute and delayed complications. Secondary endpoints were calculation of hospitalization duration, local efficacy, median survival, and median time to tumor progression. Local efficacy was evaluated on CT or positron emission tomography (PET) CT. Results: Sixty-seven patients were treated for bilateral lung metastases with RFA (mean age, 62 years). Single-session treatment was not possible in 40 due to severe pneumothoraces (n = 24), bilateral pleural contact (n = 14), and operational exclusions (n = 2). Twenty-seven (41%) received single-session RFA of lesions in both lungs for 66 metastases overall. Fourteen unilateral and four bilateral pneumothoraces occurred (18 overall, 66.7%). Unilateral (n = 13) and bilateral (n = 2) chest tube drainage was required. Median hospitalization was 3 (range, 2–8) days. Median survival was 26 months (95% confidence interval (CI), 19–33). Four recurrences on RFA sites were observed (4 patients). Median time to tumor progression was 9.5 months (95% CI, 4.2–23.5). Conclusions: Although performing single-session bilateral lung RFA is not always possible due to pneumothoraces after RFA of first lung, when it is performed, this technique is safe and effective.

  5. Single-Session Radiofrequency Ablation of Bilateral Lung Metastases

    Energy Technology Data Exchange (ETDEWEB)

    Palussiere, Jean, E-mail: palussiere@bergonie.org; Gomez, Fernando; Cannella, Matthieu; Ferron, Stephane; Descat, Edouard [Institut Bergonie, Department of Radiology, Regional Cancer Centre (France); Fonck, Marianne [Institut Bergonie, Department of Digestive Oncology (France); Brouste, Veronique [Institut Bergonie, Clinical and Epidemiological Research Unit (France); Avril, Antoine [Institut Bergonie, Department of Surgery (France)

    2012-08-15

    Purpose: This retrospective study examined the feasibility and efficacy of bilateral lung radiofrequency ablation (RFA) performed in a single session. Methods: From 2002-2009, patients with bilateral lung metastases were treated by RFA, where possible in a single session under general anesthesia with CT guidance. The second lung was punctured only if no complications occurred after treatment of the first lung. Five lung metastases maximum per patient were treated by RFA and prospectively followed. The primary endpoint was the evaluation of acute and delayed complications. Secondary endpoints were calculation of hospitalization duration, local efficacy, median survival, and median time to tumor progression. Local efficacy was evaluated on CT or positron emission tomography (PET) CT. Results: Sixty-seven patients were treated for bilateral lung metastases with RFA (mean age, 62 years). Single-session treatment was not possible in 40 due to severe pneumothoraces (n = 24), bilateral pleural contact (n = 14), and operational exclusions (n = 2). Twenty-seven (41%) received single-session RFA of lesions in both lungs for 66 metastases overall. Fourteen unilateral and four bilateral pneumothoraces occurred (18 overall, 66.7%). Unilateral (n = 13) and bilateral (n = 2) chest tube drainage was required. Median hospitalization was 3 (range, 2-8) days. Median survival was 26 months (95% confidence interval (CI), 19-33). Four recurrences on RFA sites were observed (4 patients). Median time to tumor progression was 9.5 months (95% CI, 4.2-23.5). Conclusions: Although performing single-session bilateral lung RFA is not always possible due to pneumothoraces after RFA of first lung, when it is performed, this technique is safe and effective.

  6. Outpatient single-session yttrium-90 glass microsphere radioembolization.

    Science.gov (United States)

    Gates, Vanessa L; Marshall, Karen G; Salzig, Krystina; Williams, Melissa; Lewandowski, Robert J; Salem, Riad

    2014-02-01

    To investigate the feasibility of yttrium-90 ((90)Y) glass microsphere radioembolization (including angiography, lung shunt assessment, and treatment) as a single-session, outpatient procedure. Between January 2008 and June 2013, 14 patients underwent outpatient, single-session radioembolization with (90)Y glass microspheres. As part of the routine diagnostic work-up, all patients underwent either computed tomography (CT) or magnetic resonance imaging of the liver with three-dimensional analysis and had laboratory results forwarded to our center for confirmation of candidacy before treatment. On treatment day, all patients underwent planning mesenteric angiography with flat panel cone-beam CT imaging. Patients were administered 33-85 MBq of technetium-99m macroaggregated albumin ((99m)Tc-MAA) via a microcatheter positioned in a hepatic artery supplying the tumor of interest. Planar scintigraphy was initiated within 2 hours after the administration of (99m)Tc-MAA and lung shunt fraction was determined. Final dosimetry calculations were performed while the patient was being transferred back from nuclear medicine to interventional radiology. All patients successfully underwent planning angiography with administration of (99m)Tc-MAA and (90)Y radioembolization as a single-session treatment. There were no reportable or recordable medical events; treatment was carried out to the desired dose in all cases. The mean total procedure time was 2.70 hours ± 0.72 (range, 1.63-3.97 h). This study reports a novel proof of concept for performing radioembolization in a single-session setting. By using the described method, time between initial clinical assessments and radioembolization treatment is decreased, and costs are minimized. © 2014 Published by SIR on behalf of SIR.

  7. Improved Outcomes Following a Single Session Web-Based Intervention for Problem Gambling.

    Science.gov (United States)

    Rodda, S N; Lubman, D I; Jackson, A C; Dowling, N A

    2017-03-01

    Research suggests online interventions can have instant impact, however this is yet to be tested with help-seeking adults and in particular those with problem gambling. This study seeks to determine the immediate impact of a single session web-based intervention for problem gambling, and to examine whether sessions evaluated positively by clients are associated with greater improvement. The current study involved 229 participants classified as problem gamblers who agreed to participate after accessing Gambling Help Online between November 2010 and February 2012. Almost half were aged under 35 years of age (45 %), male (57 %) as well as first time treatment seekers (62 %). Participants completed measures of readiness to change and distress both prior to and post-counselling. Following the provision of a single-session of counselling, participants completed ratings of the character of the session (i.e., degree of depth and smoothness) post-counselling. A significant increase in confidence to resist and urge to gamble and a significant decrease in distress (moderate effect size; d = .56 and .63 respectively) was observed after receiving online counselling. A hierarchical regression indicated the character of the session was a significant predictor of change in confidence, however only the sub-scale smoothness was a significant predictor of change in distress. This was the case even after controlling for pre-session distress, session word count and client characteristics (gender, age, preferred gambling activity, preferred mode of gambling, gambling severity, and preferred mode of help-seeking). These findings suggest that single session web-based counselling for problem gambling can have immediate benefits, although further research is required to examine the impact on longer-term outcomes.

  8. Changes in the biogenic amine content of the prefrontal cortex, amygdala, dorsal hippocampus, and nucleus accumbens of rats submitted to single and repeated sessions of the elevated plus-maze test

    Directory of Open Access Journals (Sweden)

    Carvalho M.C.

    2005-01-01

    Full Text Available It has been demonstrated that exposure to a variety of stressful experiences enhances fearful reactions when behavior is tested in current animal models of anxiety. Until now, no study has examined the neurochemical changes during the test and retest sessions of rats submitted to the elevated plus maze (EPM. The present study uses a new approach (HPLC by looking at the changes in dopamine and serotonin levels in the prefrontal cortex, amygdala, dorsal hippocampus, and nucleus accumbens in animals upon single or double exposure to the EPM (one-trial tolerance. The study involved two experiments: i saline or midazolam (0.5 mg/kg before the first trial, and ii saline or midazolam before the second trial. For the biochemical analysis a control group injected with saline and not tested in the EPM was included. Stressful stimuli in the EPM were able to elicit one-trial tolerance to midazolam on re-exposure (61.01%. Significant decreases in serotonin contents occurred in the prefrontal cortex (38.74%, amygdala (78.96%, dorsal hippocampus (70.33%, and nucleus accumbens (73.58% of the animals tested in the EPM (P < 0.05 in all cases in relation to controls not exposed to the EPM. A significant decrease in dopamine content was also observed in the amygdala (54.74%, P < 0.05. These changes were maintained across trials. There was no change in the turnover rates of these monoamines. We suggest that exposure to the EPM causes reduced monoaminergic neurotransmission activity in limbic structures, which appears to underlie the "one-trial tolerance" phenomenon.

  9. Single-session vs multiple-session pattern scanning laser panretinal photocoagulation in proliferative diabetic retinopathy: The Manchester Pascal Study.

    Science.gov (United States)

    Muqit, Mahiul M K; Marcellino, George R; Henson, David B; Young, Lorna B; Patton, Niall; Charles, Stephen J; Turner, George S; Stanga, Paulo E

    2010-05-01

    To investigate the effects of pattern scanning laser (Pascal; OptiMedica, Santa Clara, California) multispot panretinal photocoagulation given in a single-session (SS-PRP) vs single-spot multiple-session PRP (MS-PRP) on proliferative diabetic retinopathy (PDR). Single-center, randomized clinical trial of 40 eyes. Proliferative diabetic retinopathy was treated with a 400-mum spot size in 1500 burns given either as Pascal in 20-millisecond SS-PRP or in 3 sessions (100-millisecond MS-PRP) during a 4-week period. Visual acuity, central subfield retinal thickness (CRT), and 24-2 Swedish interactive thresholding algorithm visual fields were recorded at baseline and 4 and 12 weeks. Central subfield retinal thickness, mean deviation, and PDR grade at 12 weeks. There was a significant increase in mean CRT with MS-PRP (22 mum at 4 weeks, 95% CI, -32.25 to -10.75; 20 mum at 12 weeks, 95% CI, -28.75 to -10.82; P Pascal SS-PRP was as effective as MS-PRP in the treatment of PDR. Twenty-millisecond Pascal SS-PRP may be safely and rapidly performed in 1500 burns with a similar efficacy to conventional MS-PRP. TRIAL IDENTIFIER: Research and Development Office PIN R00037, Central Manchester University Hospitals Foundation Trust.

  10. Oxygen saturation and heart rate monitoring during a single session of early rehabilitation after cardiac surgery.

    Science.gov (United States)

    Sala, Vittorio; Petrucci, Lucia; Monteleone, Serena; Dall'Angelo, Anna; Miracca, Stefania; Conte, Teresa; Carlisi, Ettore; Ricotti, Susanna; D'Armini, Andrea M; Dalla Toffola, Elena

    2016-02-01

    Early rehabilitation after cardiac surgery aims to prevent immobilization, to reduce the effects of surgery on the respiratory function and to facilitate the recovery of autonomy in the activities of daily living (ADL), after discharge. Nevertheless the optimal perioperative physical therapy care for patients undergoing cardiac surgery is not well established. Moreover, most of the studies monitored peripheral oxygen saturation (SpO2) and heart rate (HR) during surgery or focused only on their recovery after rehabilitation and not on their pathways during a session of exercises. To monitor peripheral oxygen saturation and HR before, during and at the end of a single session of early rehabilitation after cardiac surgery, so testing our protocol's safety. A case series. Department of Cardiothoracic Surgery, inpatients. Forty-eight consecutive inpatients (35 M), mean age 61 years, with cardiovascular disease (CVD), who underwent cardiac surgery. We monitored SpO2%, HR, systemic blood pressure (BP), pain in the thoracic wound (VAS) and rate of perceived exertion (RPE) during the rehabilitation session after weaning from oxygen therapy. During all phases mean SpO2 was 94% (±1.8) and mean HR was 85 bpm (±13.3). Number of desaturation events were 14 in total and mean of % of time with SpO2<90% was 3 (±6.5) during all the rehabilitative session. Moreover, mean BP after reaching the sitting position was 124.7 (±11.9)/78.6 (±8.4) and after ambulation was 131.5 (±11.5)/82.9 (±7.3). The monitoring peripheral oxygen saturation and HR during and not only before and at the end of a standardized early rehabilitation session helped us to ensure the safety of our protocol. Because of its feasibility, safety and reproducibility our rehabilitation treatment has been applied to different types of surgical inpatients in order to limit the negative consequences of immobilization.

  11. Single session of Nd:YAG laser intracanal irradiation neutralizes endotoxin in dental root dentin

    Science.gov (United States)

    Archilla, José R. F.; Moreira, Maria S. N. A.; Miyagi, Sueli P. H.; Bombana, Antônio C.; Gutknecht, Norbert; Marques, Márcia M.

    2012-11-01

    Endotoxins released in the dental root by Gram-negative microorganisms can be neutralized by calcium hydroxide, when this medication is applied inside the root canal for at least seven days. However, several clinical situations demand faster root canal decontamination. Thus, for faster endotoxin neutralization, endodontists are seeking additional treatments. The in vitro study tested whether or not intracanal Nd:YAG laser irradiation would be able to neutralize endotoxin within the human dental root canal in a single session. Twenty-four human teeth with one root were mounted between two chambers. After conventional endodontic treatment, root canals were contaminated with Escherichia coli endotoxin. Then they were irradiated or not (controls) in contact mode with an Nd:YAG laser (1.5 W, 15 Hz, 100 mJ and pulse fluency of 124 J/cm2). The endotoxin activity was measured using the limulus lysate technique and data were statistically compared (p≤0.05). The concentration of active endotoxin measured in the negative control group was significantly lower than that of the positive control group (p=0.04). The concentrations of endotoxin in both irradiated groups were significantly lower than that of the positive control group (p=0.027) and similar to that of negative control group (p=0.20). A single session of intracanal Nd:YAG laser irradiation is able to neutralize endotoxin in the dental root tissues.

  12. Single session of Nd:YAG laser intracanal irradiation neutralizes endotoxin in dental root dentin.

    Science.gov (United States)

    Archilla, José R F; Moreira, Maria S N A; Miyagi, Sueli P H; Bombana, Antônio C; Gutknecht, Norbert; Marques, Márcia M

    2012-11-01

    Endotoxins released in the dental root by Gram-negative microorganisms can be neutralized by calcium hydroxide, when this medication is applied inside the root canal for at least seven days. However, several clinical situations demand faster root canal decontamination. Thus, for faster endotoxin neutralization, endodontists are seeking additional treatments. The in vitro study tested whether or not intracanal Nd:YAG laser irradiation would be able to neutralize endotoxin within the human dental root canal in a single session. Twenty-four human teeth with one root were mounted between two chambers. After conventional endodontic treatment, root canals were contaminated with Escherichia coli endotoxin. Then they were irradiated or not (controls) in contact mode with an Nd:YAG laser (1.5 W, 15 Hz, 100 mJ and pulse fluency of 124  J/cm2). The endotoxin activity was measured using the limulus lysate technique and data were statistically compared (p≤0.05). The concentration of active endotoxin measured in the negative control group was significantly lower than that of the positive control group (p=0.04). The concentrations of endotoxin in both irradiated groups were significantly lower than that of the positive control group (p=0.027) and similar to that of negative control group (p=0.20). A single session of intracanal Nd:YAG laser irradiation is able to neutralize endotoxin in the dental root tissues.

  13. Single Session of Functional Electrical Stimulation-Assisted Walking Produces Corticomotor Symmetry Changes Related to Changes in Poststroke Walking Mechanics.

    Science.gov (United States)

    Palmer, Jacqueline A; Hsiao, HaoYuan; Wright, Tamara; Binder-Macleod, Stuart A

    2017-05-01

    Recent research demonstrated that the symmetry of corticomotor drive with the paretic and nonparetic plantarflexor muscles was related to the biomechanical ankle moment strategy that people with chronic stroke used to achieve their greatest walking speeds. Rehabilitation strategies that promote corticomotor balance might improve poststroke walking mechanics and enhance functional ambulation. The study objectives were to test the effectiveness of a single session of gait training using functional electrical stimulation (FES) to improve plantarflexor corticomotor symmetry and plantarflexion ankle moment symmetry and to determine whether changes in corticomotor symmetry were related to changes in ankle moment symmetry within the session. This was a repeated-measures crossover study. On separate days, 20 people with chronic stroke completed a session of treadmill walking either with or without the use of FES of their ankle dorsi- and plantarflexor muscles. We calculated plantarflexor corticomotor symmetry using transcranial magnetic stimulation and plantarflexion ankle moment symmetry during walking between the paretic and the nonparetic limbs before and after each session. We compared changes and tested relationships between corticomotor symmetry and ankle moment symmetry following each session. Following the session with FES, there was an increase in plantarflexor corticomotor symmetry that was related to the observed increase in ankle moment symmetry. In contrast, following the session without FES, there were no changes in corticomotor symmetry or ankle moment symmetry. No stratification was made on the basis of lesion size, location, or clinical severity. These findings demonstrate, for the first time (to our knowledge), the ability of a single session of gait training with FES to induce positive corticomotor plasticity in people in the chronic stage of stroke recovery. They also provide insight into the neurophysiologic mechanisms underlying improvements in

  14. Irisin in blood increases transiently after single sessions of intense endurance exercise and heavy strength training.

    Science.gov (United States)

    Nygaard, Håvard; Slettaløkken, Gunnar; Vegge, Geir; Hollan, Ivana; Whist, Jon Elling; Strand, Tor; Rønnestad, Bent R; Ellefsen, Stian

    2015-01-01

    Irisin is a recently identified exercise-induced hormone that increases energy expenditure, at least in rodents. The main purpose of this study was to test the hypothesis that Irisin increases acutely in blood after singular sessions of intense endurance exercise (END) and heavy strength training (STR). Secondary, we wanted to explore the relationship between body composition and exercise-induced effects on irisin, and the effect of END and STR on muscular expression of the irisin gene FNDC5. Nine moderately trained healthy subjects performed three test days using a randomized and standardized crossover design: one day with 60 minutes of END, one day with 60 minutes of STR, and one day without exercise (CON). Venous blood was sampled over a period of 24h on the exercise days. Both END and STR led to transient increases in irisin concentrations in blood, peaking immediately after END and one hour after STR, before gradually returning to baseline. Irisin responses to STR, but not END, showed a consistently strong negative correlation with proportions of lean body mass. Neither END nor STR affected expression of FNDC5, measured 4h after training sessions, though both protocols led to pronounced increases in PGC-1α expression, which is involved in transcriptional control of FNDC5. The results strongly suggest that single sessions of intense endurance exercise and heavy strength training lead to transient increases in irisin concentrations in blood. This was not accompanied by increased FNDC5 expression, measured 4h post-exercise. The results suggest that irisin responses to resistance exercise are higher in individuals with lower proportions of lean body mass.

  15. A single session of exercise as a modulator of short-term learning in healthy individuals.

    Science.gov (United States)

    Sage, Michael D; Beyer, Kit B; Laylor, Mark; Liang, Carmen; Roy, Eric A; McIlroy, William E

    2016-08-26

    A single session of aerobic exercise is linked to faster motor responses; however, the effect on rate of short-term learning is less clear. The objective was to evaluate the influence of a single bout of aerobic exercise on the rate of short-term acquisition of a shape-letter association task requiring a motor response. 23 [11 females, age 20.8±2.7years] healthy young adults were evaluated using a randomly assigned crossover design which was counterbalanced for order before and after moderate (exercise) and light (control) intensity cycle ergometry. Participants performed 3 blocks, with each block consisting of one round of training and testing. During training, participants were tasked with learning 6 unique shape-letter associations. Subsequent testing required a key press response to a visually presented shape pattern. Response time and error rates were used to assess acquisition over the 3 blocks of testing. Mean response time was faster post-exercise relative to the other testing periods, and approached statistical significance compared to post-control (pexercise and control conditions). Error rate reduction (test block 1 minus test block 3) revealed that individuals had the smallest change in error rate post-exercise (pexercise which approached statistical significance (p=0.06) suggesting near-perfect error rates were obtained after only 2 testing blocks post-exercise compared to 3 blocks in the other testing periods. Support for augmentation of short-term learning was mixed as errors were reduced post-exercise while response time was not different between evaluations. Future work should include neurophysiological evaluation and a retention test to better elucidate the influence of aerobic exercise on rate of short-term learning. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  16. Evaluation of a Single-Session Brief Motivational Enhancement Intervention for Partner Abusive Men

    Science.gov (United States)

    Crane, Cory A.; Eckhardt, Christopher I.

    2013-01-01

    The current study evaluated the efficacy of a single-session brief motivational enhancement (BME) interview to increase treatment compliance and reduce recidivism rates in a sample of 82 recently adjudicated male perpetrators of intimate partner violence (IPV). Batterer intervention program attendance and completion as well as re-arrest records…

  17. Single session email consultation for parents : An evaluation of its effect on empowerment

    NARCIS (Netherlands)

    prof.dr. Jo Hermanns; prof.dr. Ruben Fukkink; dr. Christa C.C. Nieuwboer

    2014-01-01

    This study evaluated the effect of single session email consultation on empowerment of parents. Practitioners in a control group (N = 19) received no training; practitioners in an experimental group (N = 21) were trained to use empowerment oriented techniques in online consultation. Parental

  18. Single Session Email Consultation for Parents: An Evaluation of Its Effect on Empowerment

    Science.gov (United States)

    Nieuwboer, Christa C.; Fukkink, Ruben G.; Hermanns, Jo M. A.

    2015-01-01

    This study evaluated the effect of single session email consultation (SSEC) on empowerment of parents. Practitioners in a control group (n = 19) received no training and practitioners in an experimental group (n = 21) were trained to use empowerment-oriented techniques in online consultation. Parental empowerment was measured (n = 96) through a…

  19. Clinical Perspective A case of effective single-session treatment for ...

    African Journals Online (AJOL)

    This article reports a systematic clinical case study of the psychological assessment and treatment of Daniel (9), a coloured South African boy with a diagnosis of attention deficit hyperactivity disorder (ADHD) (inattentive type). The case is of scientific interest because: (1) there was only a single treatment session, in which ...

  20. Single-session versus staged procedures for elective multivessel percutaneous coronary intervention.

    Science.gov (United States)

    Toyota, Toshiaki; Morimoto, Takeshi; Shiomi, Hiroki; Yamaji, Kyohei; Ando, Kenji; Ono, Koh; Shizuta, Satoshi; Saito, Naritatsu; Kato, Takao; Kaji, Shuichiro; Furukawa, Yutaka; Nakagawa, Yoshihisa; Kadota, Kazushige; Horie, Minoru; Kimura, Takeshi

    2017-11-16

    To clarify the effect of single-session multivessel percutaneous coronary intervention (PCI) strategy relative to the staged multivessel strategy on clinical outcomes in patients with stable coronary artery disease (CAD) or non-ST-elevation acute coronary syndrome. In the Coronary REvascularisation Demonstrating Outcome Study in Kyoto PCI/coronary artery bypass grafting registry cohort-2, there were 2018 patients who underwent elective multivessel PCI. Primary outcome measure was composite of all-cause death, myocardial infarction and stroke at 5-year follow-up. Single-session multivessel PCI and staged multivessel PCI were performed in 707 patients (35.0%) and 1311 patients (65.0%), respectively. The cumulative 5-year incidence of and adjusted risk for the primary outcome measure were not significantly different between the single-session and staged groups (26.7% vs 23.0%, p=0.45; HR 0.91, 95% CI 0.72 to 1.16, p=0.47). The 30-day incidence of all-cause death was significantly higher in the single-session group than in the staged group (1.1% vs 0.2%, p=0.009). However, the causes of death in 11 patients who died within 30 days were generally not related to the procedural complications, but related to the serious clinical status before PCI. For the subgroup analyses including age, gender, extent of CAD, severe chronic kidney disease and heart failure, there was no significant interaction between the subgroup factors and the effect of the single-session strategy relative to the staged strategy for the primary outcome measure. The single-session multivessel PCI strategy was associated with at least comparable 5-year clinical outcomes compared with the staged multivessel PCI, although the prevalence of the single-session strategy was low in the present study. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  1. A single alcohol drinking session is sufficient to enable subsequent aversion-resistant consumption in mice.

    Science.gov (United States)

    Lei, Kelly; Wegner, Scott A; Yu, Ji-Hwan; Simms, Jeffrey A; Hopf, F Woodward

    2016-09-01

    Addiction is mediated in large part by pathological motivation for rewarding, addictive substances, and alcohol-use disorders (AUDs) continue to extract a very high physical and economic toll on society. Compulsive alcohol drinking, where intake continues despite negative consequences, is considered a particular obstacle during treatment of AUDs. Aversion-resistant drives for alcohol have been modeled in rodents, where animals continue to consume even when alcohol is adulterated with the bitter tastant quinine, or is paired with another aversive consequence. Here, we describe a two-bottle choice paradigm where C57BL/6 mice first had 24-h access to 15% alcohol or water. Afterward, they drank quinine-free alcohol (alcohol-only) or alcohol with quinine (100 μM), in a limited daily access (LDA) two-bottle-choice paradigm (2 h/day, 5 days/week, starting 3 h into the dark cycle), and achieved nearly binge-level blood alcohol concentrations. Interestingly, a single, initial 24-h experience with alcohol-only enhanced subsequent quinine-resistant drinking. In contrast, mice that drank alcohol-quinine in the 24-h session showed significantly reduced alcohol-quinine intake and preference during the subsequent LDA sessions, relative to mice that drank alcohol-only in the initial 24-h session and alcohol-quinine in LDA sessions. Thus, mice could find the concentration of quinine we used aversive, but were able to disregard the quinine after a single alcohol-only drinking session. Finally, mice had low intake and preference for quinine in water, both before and after weeks of alcohol-drinking sessions, suggesting that quinine resistance was not a consequence of increased quinine preference after weeks of drinking of alcohol-quinine. Together, we demonstrate that a single alcohol-only session was sufficient to enable subsequent aversion-resistant consumption in C57BL/6 mice, which did not reflect changes in quinine taste palatability. Given the rapid development of quinine

  2. Single-session treatment of a major complication of dens invaginatus: a case report.

    Science.gov (United States)

    Caldari, Mauro; Monaco, Carlo; Ciocca, Leonardo; Scotti, Roberto

    2006-05-01

    Dens invaginatus is a dental malformation that may give rise to several complications. Caries of the invagination can severely weaken the whole tooth, making it susceptible to fracture. Subgingival fractures are major complications threatening tooth survival and usually require periodontal/orthodontic/prosthetic treatment if long-term viability is to be ensured. This article describes a case of single-session restoration of a fractured invaginated tooth by means of endodontic treatment followed by fragment reattachment.

  3. Single session of integrated "Silver Yoga" program improves cardiovascular parameters in senior citizens

    Directory of Open Access Journals (Sweden)

    Ananda Balayogi Bhavanani

    2015-06-01

    Conclusion: There is a healthy reduction in HR, BP and derived cardiovascular indices following a single yoga session in geriatric subjects. These changes may be attributed to enhanced harmony of cardiac autonomic function as a result of coordinated breath-body work and mind-body relaxation due to an integrated and #8220;Silver Yoga and #8221; program. [J Intercult Ethnopharmacol 2015; 4(2.000: 134-137

  4. Micrograft and minigraft megasession hair transplantation results after a single session.

    Science.gov (United States)

    Barrera, A

    1997-11-01

    The purpose of this article is to share observations made after performing 90 consecutive micrograft and minigraft megasessions for the treatment of male pattern baldness. Micrograft means grafts with 1 or 2 hairs, minigrafts are those with 3 or 4 hairs, and a megasession is a procedure in which more than 1000 micrografts and minigrafts are inserted in a single session. Between March of 1994 and June of 1996, the author performed 90 consecutive micrograft and minigraft megasessions on 86 men and 4 women ranging from 21 to 67 years of age (average age, 42 years). The surgical team consisted of three surgical assistants and a plastic surgeon. Today, usually between 1500 and 2000 grafts per session are performed in about 4 to 6 hours, with up to 2495 grafts done in a single session. All procedures were done under intravenous sedation and local anesthesia. A donor horizontal ellipse of scalp is harvested from the occipital area; the grafts are made out of it and then inserted through small slits. The procedure has been found to be safe and predictable with natural and aesthetically pleasing results, and there were no serious complications. The only complication found in this group was self-resolving inclusion cysts (ingrown hairs) occurring in 9 of 90 patients (10 percent). Even though the hair density achieved in a single megasession is limited, there is a high level of patient satisfaction: 83 of 85 patients were satisfied (97.65 percent).

  5. From Catastrophizing to Recovery: a pilot study of a single-session treatment for pain catastrophizing

    Directory of Open Access Journals (Sweden)

    Darnall BD

    2014-04-01

    Full Text Available Beth D Darnall, John A Sturgeon, Ming-Chih Kao, Jennifer M Hah, Sean C MackeyDivision of Pain Medicine, Stanford Systems Neuroscience and Pain Laboratory, Stanford University School of Medicine, Palo Alto, CA, USABackground: Pain catastrophizing (PC – a pattern of negative cognitive-emotional responses to real or anticipated pain – maintains chronic pain and undermines medical treatments. Standard PC treatment involves multiple sessions of cognitive behavioral therapy. To provide efficient treatment, we developed a single-session, 2-hour class that solely treats PC entitled “From Catastrophizing to Recovery”[FCR].Objectives: To determine 1 feasibility of FCR; 2 participant ratings for acceptability, understandability, satisfaction, and likelihood to use the information learned; and 3 preliminary efficacy of FCR for reducing PC.Design and methods: Uncontrolled prospective pilot trial with a retrospective chart and database review component. Seventy-six patients receiving care at an outpatient pain clinic (the Stanford Pain Management Center attended the class as free treatment and 70 attendees completed and returned an anonymous survey immediately post-class. The Pain Catastrophizing Scale (PCS was administered at class check-in (baseline and at 2, and 4 weeks post-treatment. Within subjects repeated measures analysis of variance (ANOVA with Student's t-test contrasts were used to compare scores across time points.Results: All attendees who completed a baseline PCS were included as study participants (N=57; F=82%; mean age =50.2 years; PCS was completed by 46 participants at week 2 and 35 participants at week 4. Participants had significantly reduced PC at both time points (P<0001 and large effect sizes were found (Cohen's d=0.85 and d=1.15.Conclusion: Preliminary data suggest that FCR is an acceptable and effective treatment for PC. Larger, controlled studies of longer duration are needed to determine durability of response, factors

  6. The effects of a single session of spinal manipulation on strength and cortical drive in athletes

    DEFF Research Database (Denmark)

    Christiansen, Thomas Lykke; Niazi, Imran Khan; Holt, Kelly

    2018-01-01

    PURPOSE: The primary purpose of this study was to investigate whether a single session of spinal manipulation (SM) increases strength and cortical drive in the lower limb (soleus muscle) of elite Taekwondo athletes. METHODS: Soleus-evoked V-waves, H-reflex and maximum voluntary contraction (MVC......) of the plantar flexors were recorded from 11 elite Taekwondo athletes using a randomized controlled crossover design. Interventions were either SM or passive movement control. Outcomes were assessed at pre-intervention and at three post-intervention time periods (immediate post, post 30 min and post 60 min......). A multifactorial repeated measures ANOVA was conducted to assess within and between group differences. Time and session were used as factors. A post hoc analysis was carried out, when an interactive effect was present. Significance was set at p ≤ 0.05. RESULTS: SM increased MVC force [F(3,30) = 5.95, p 

  7. One night of partial sleep deprivation impairs recovery from a single exercise training session.

    Science.gov (United States)

    Rae, Dale E; Chin, Tayla; Dikgomo, Kagiso; Hill, Lee; McKune, Andrew J; Kohn, Tertius A; Roden, Laura C

    2017-04-01

    The effects of sleep deprivation on physical performance are well documented, but data on the consequence of sleep deprivation on recovery from exercise are limited. The aim was to compare cyclists' recovery from a single bout of high-intensity interval training (HIIT) after which they were given either a normal night of sleep (CON, 7.56 ± 0.63 h) or half of their usual time in bed (DEP, 3.83 ± 0.33 h). In this randomized cross-over intervention study, 16 trained male cyclists (age 32 ± 7 years), relative peak power output (PPO 4.6 ± 0.7 W kg -1 ) performed a HIIT session at ±18:00 followed by either the CON or DEP sleep condition. Recovery from the HIIT session was assessed the following day by comparing pre-HIIT variables to those measured 12 and 24 h after the session. Following a 2-week washout, cyclists repeated the trial, but under the alternate sleep condition. PPO was reduced more 24 h after the HIIT session in the DEP (ΔPPO -0.22 ± 0.22 W kg -1 ; range -0.75 to 0.1 W kg -1 ) compared to the CON condition (ΔPPO -0.05 ± 0.09 W kg -1 , range -0.19 to 0.17 W kg -1 , p = 0.008, d = -2.16). Cyclists were sleepier (12 h: p = 0.002, d = 1.90; 24 h: p = 0.001, d = 1.41) and felt less motivated to train (12 h, p = 0.012, d = -0.89) during the 24 h recovery phase when the HIIT session was followed by the DEP condition. The exercise-induced 24 h reduction in systolic blood pressure observed in the CON condition was absent in the DEP condition (p = 0.039, d = 0.75). One night of partial sleep deprivation impairs recovery from a single HIIT session in cyclists. Further research is needed to understand the mechanisms behind this observation.

  8. Bilateral Single-Session Retrograde Intrarenal Surgery for the Treatment of Bilateral Renal Stones

    Directory of Open Access Journals (Sweden)

    Gokhan Atis

    2013-06-01

    Full Text Available Purpose The aim of the study was to evaluate the efficacy and safety of bilateral single-session retrograde intrarenal surgery in the treatment of bilateral renal stones. Materials and Methods From December 2008 to February 2012, 42 patients who had undergone bilateral single-session retrograde intrarenal surgery (RIRS and laser lithotripsy were included in the study. The procedures were performed in the lithotomy position on an endoscopy table under general anesthesia, beginning on the side in which the stone size was smaller. Plain abdominal radiography, intravenous urograms (IVU, renal ultrasonography (USG and / or non-contrast tomography (CT scans were conducted for all patients. The success rate was defined as patients who were stone-free or only had residual fragment less than 4 mm. Results A total of 42 patients (28 male, 14 female with a mean age 39.2 ± 14.2 were included in the present study. The mean stone size was 24.09 ± 6.37 mm with a mean operative time of 51.08 ± 15.22 minutes. The stone-free rates (SFR were 92.8% and 97.6% after the first and second procedures, respectively. The average hospital stay was 1.37 ± 0.72 days. In two patients (4.7%, minor complications (Clavien I or II were observed, whereas no major complications (Clavien III-V or blood transfusions were noted in the studied group. Conclusions Bilateral single-session RIRS and laser lithotripsy can be performed safely and effectively with a high success rate and low complication rate in patients with bilateral renal stones.

  9. The effects of a single session of spinal manipulation on strength and cortical drive in athletes

    DEFF Research Database (Denmark)

    Christiansen, Thomas Lykke; Niazi, Imran Khan; Holt, Kelly

    2018-01-01

    PURPOSE: The primary purpose of this study was to investigate whether a single session of spinal manipulation (SM) increases strength and cortical drive in the lower limb (soleus muscle) of elite Taekwondo athletes. METHODS: Soleus-evoked V-waves, H-reflex and maximum voluntary contraction (MVC.......01], and V-waves [F(3,30) = 4.25, p = 0.01] over time compared to the control intervention. Between group differences were significant for all time periods (p strength and corticospinal...

  10. Effects of a single-session assertiveness music therapy role playing protocol for psychiatric inpatients.

    Science.gov (United States)

    Silverman, Michael J

    2011-01-01

    The purpose of this study was to implement and measure the effectiveness of a single-session assertiveness music therapy role playing protocol for psychiatric inpatients. Participants (N=133) were randomly assigned by group to one of three conditions: (a) Assertiveness Music Therapy, (b) No Music Assertiveness, or (c) Music No Assertiveness. Participants in both assertiveness conditions role played a number of different commonly occurring scenarios at an inpatient psychiatric facility and in the community. There were no significant between-group differences in posttest quality of life, locus of control, or other subscales. However, participants in both assertiveness conditions tended to have slightly higher internal locus of control and overall quality of life scores than participants in the music no assertiveness condition. Additionally, the assertiveness music therapy condition had higher attendance rates than the other conditions. A higher percentage of participants from both the assertiveness music therapy and music no assertiveness conditions indicated they thought their session was the most helpful/therapeutic group therapy session in which they had participated; this was not the case for the assertiveness no music condition. Future research is warranted to measure the effects of protocols that can help psychiatric patients generalize skills learned in treatment.

  11. The effects of a single session of spinal manipulation on strength and cortical drive in athletes.

    Science.gov (United States)

    Christiansen, Thomas Lykke; Niazi, Imran Khan; Holt, Kelly; Nedergaard, Rasmus Wiberg; Duehr, Jens; Allen, Kathryn; Marshall, Paul; Türker, Kemal S; Hartvigsen, Jan; Haavik, Heidi

    2018-04-01

    The primary purpose of this study was to investigate whether a single session of spinal manipulation (SM) increases strength and cortical drive in the lower limb (soleus muscle) of elite Taekwondo athletes. Soleus-evoked V-waves, H-reflex and maximum voluntary contraction (MVC) of the plantar flexors were recorded from 11 elite Taekwondo athletes using a randomized controlled crossover design. Interventions were either SM or passive movement control. Outcomes were assessed at pre-intervention and at three post-intervention time periods (immediate post, post 30 min and post 60 min). A multifactorial repeated measures ANOVA was conducted to assess within and between group differences. Time and session were used as factors. A post hoc analysis was carried out, when an interactive effect was present. Significance was set at p ≤ 0.05. SM increased MVC force [F(3,30) = 5.95, p < 0.01], and V-waves [F(3,30) = 4.25, p = 0.01] over time compared to the control intervention. Between group differences were significant for all time periods (p < 0.05) except for the post60 force measurements (p = 0.07). A single session of SM increased muscle strength and corticospinal excitability to ankle plantar flexor muscles in elite Taekwondo athletes. The increased MVC force lasted for 30 min and the corticospinal excitability increase persisted for at least 60 min.

  12. Comparative Efficacy and Mechanisms of a Single-Session Pain Psychology Class in Chronic Low Back Pain: Study Protocol for a Randomized Controlled Trial.

    Science.gov (United States)

    Darnall, Beth D; Ziadni, Maisa S; Roy, Anuradha; Kao, Ming-Chih; Sturgeon, John A; Cook, Karon F; Lorig, Kate; Burns, John W; Mackey, Sean C

    2018-03-06

    The Institute of Medicine (IOM) reported that chronic pain affects about 100 million U.S. adults, with chronic low back pain (CLBP) cited as the most prevalent type. Pain catastrophizing is a psychological construct shown to predict the development and trajectory of chronic pain and patient response to pain treatments. While effective treatment for pain catastrophizing typically includes eight-session groups of cognitive behavioral therapy (CBT), a single-session targeted treatment class yielded promising results which, if replicated and extended, could prove to efficiently and cost-effectively reduce pain catastrophizing. In this trial, we seek to determine the comparative efficacy of this novel single-session pain catastrophizing class to an eight-session course of pain CBT and a single-session back pain health education class. We will also explore the psychosocial mechanisms and outcomes of pain catastrophizing treatment. In this trial we will randomize 231 individuals with CLBP to one of three treatment arms: (1) pain-CBT (eight weekly 2-h group sessions with home exercises and readings); (2) a single 2-h pain catastrophizing class; or (3) a single 2-h back pain health education class (active control). For the primary outcome of pain catastrophizing, the trial is designed as a non-inferiority test between pain-CBT and the single-session pain catastrophizing class, and as a superiority test between the single-session pain catastrophizing class and the health education class. Team researchers masked to treatment assignment will assess outcomes up to six months post treatment. If the single-session targeted pain catastrophizing class is found to be an effective treatment for patients with CLBP, this low cost and low burden treatment could dismantle many of the current barriers and burdens of effective pain care. Further, elucidation of the mechanisms of pain catastrophizing treatments will facilitate future research on the topic as well as further development and

  13. Breaking HIV News to Clients: SPIKES Strategy in Post-Test Counseling Session

    Directory of Open Access Journals (Sweden)

    Hamid Emadi-Koochak

    2016-05-01

    Full Text Available Breaking bad news is one of the most burdensome tasks physicians face in their everyday practice. It becomes even more challenging in the context of HIV+ patients because of stigma and discrimination. The aim of the current study is to evaluate the quality of giving HIV seroconversion news according to SPIKES protocol. Numbers of 154 consecutive HIV+ patients from Imam Khomeini Hospital testing and counseling center were enrolled in this study. Patients were inquired about how they were given the HIV news and whether or not they received pre- and post-test counseling sessions. Around 51% of them were men, 80% had high school education, and 56% were employed. Regarding marital status, 32% were single, and 52% were married at the time of the interview. Among them, 31% had received the HIV news in a counseling center, and only 29% had pre-test counseling. SPIKES criteria were significantly met when the HIV news was given in an HIV counseling and testing center (P.value<0.05. Low coverage of HIV counseling services was observed in the study. SPIKES criteria were significantly met when the HIV seroconversion news was given in a counseling center. The need to further train staff to deliver HIV news seems a priority in the field of HIV care and treatment.

  14. Single session vs two sessions of flexible ureterosopy (FURS) for dusting of renal pelvic stones 2–3 cm in diameter: Does stone size or hardness play a role in number of sessions to be applied?”

    Science.gov (United States)

    El Hamed, Ahmed Mamdouh Abd; Elmoghazy, Hazem; Aldahshoury, Mohamed; Riad, Ahmed; Mostafa, Mohammed; Farag, Fawzy; Gamal, Wael

    2017-01-01

    Objective To evaluate the stone hardness in predicting the need for single or two sessions of retrograde intrarenal surgery (RIRS) for renal pelvis stones of 2–3 cm in size. Material and methods Ninety-six patients (64 male and 32 female) with only renal stones (2.5±0.3 cm) underwent RIRS using flexible 7.5 Fr ureteroscope (FURS). The stone hardness was evaluated by preoperative non-contrast computed tomography (NCCT). The patients were divided into two groups based on stone hardness: Group I (n=54) (hard stones - Hounsfield Unit (HU) >1000) and group II (n=42) (not hard stone - HU <1000). The stone-free rate, the operative time, any intra or postoperative complications and the need for second sessions of RIRS were evaluated. Results All stones were successfully accessed. Intraoperative complications were not reported. The initial stone-free rate was 40% in Group I and 95% in Group II after a single session (p=0.01). A second session FURS was needed in 32 cases of Group I (40%) where postoperative CT showed significant residual stone fragments of 6±2 mm, and stone-free rate up to 100 percent. On the contrary only 2 cases from Group II underwent second session FURS (p=0.01). The operative times were 75±15 minutes in Group I and 55±13 minutes in Group II (p<0.01). Six patients (4 in group I and 2 in group II) had postoperative high-grade fever (Clavien Grade II). Conclusion Stone hardness had a significant impact on the decision of performing single versus two sessions of FURS for renal pelvic stones of 2–3 cm rather than the stone size alone. PMID:28717539

  15. Single session vs two sessions of flexible ureterosopy (FURS) for dusting of renal pelvic stones 2-3 cm in diameter: Does stone size or hardness play a role in number of sessions to be applied?"

    Science.gov (United States)

    El Hamed, Ahmed Mamdouh Abd; Elmoghazy, Hazem; Aldahshoury, Mohamed; Riad, Ahmed; Mostafa, Mohammed; Farag, Fawzy; Gamal, Wael

    2017-06-01

    To evaluate the stone hardness in predicting the need for single or two sessions of retrograde intrarenal surgery (RIRS) for renal pelvis stones of 2-3 cm in size. Ninety-six patients (64 male and 32 female) with only renal stones (2.5±0.3 cm) underwent RIRS using flexible 7.5 Fr ureteroscope (FURS). The stone hardness was evaluated by preoperative non-contrast computed tomography (NCCT). The patients were divided into two groups based on stone hardness: Group I (n=54) (hard stones - Hounsfield Unit (HU) >1000) and group II (n=42) (not hard stone - HU <1000). The stone-free rate, the operative time, any intra or postoperative complications and the need for second sessions of RIRS were evaluated. All stones were successfully accessed. Intraoperative complications were not reported. The initial stone-free rate was 40% in Group I and 95% in Group II after a single session (p=0.01). A second session FURS was needed in 32 cases of Group I (40%) where postoperative CT showed significant residual stone fragments of 6±2 mm, and stone-free rate up to 100 percent. On the contrary only 2 cases from Group II underwent second session FURS (p=0.01). The operative times were 75±15 minutes in Group I and 55±13 minutes in Group II (p<0.01). Six patients (4 in group I and 2 in group II) had postoperative high-grade fever (Clavien Grade II). Stone hardness had a significant impact on the decision of performing single versus two sessions of FURS for renal pelvic stones of 2-3 cm rather than the stone size alone.

  16. SINGLE HEATER TEST FINAL REPORT

    Energy Technology Data Exchange (ETDEWEB)

    J.B. Cho

    1999-05-01

    The Single Heater Test is the first of the in-situ thermal tests conducted by the U.S. Department of Energy as part of its program of characterizing Yucca Mountain in Nevada as the potential site for a proposed deep geologic repository for the disposal of spent nuclear fuel and high-level nuclear waste. The Site Characterization Plan (DOE 1988) contained an extensive plan of in-situ thermal tests aimed at understanding specific aspects of the response of the local rock-mass around the potential repository to the heat from the radioactive decay of the emplaced waste. With the refocusing of the Site Characterization Plan by the ''Civilian Radioactive Waste Management Program Plan'' (DOE 1994), a consolidated thermal testing program emerged by 1995 as documented in the reports ''In-Situ Thermal Testing Program Strategy'' (DOE 1995) and ''Updated In-Situ Thermal Testing Program Strategy'' (CRWMS M&O 1997a). The concept of the Single Heater Test took shape in the summer of 1995 and detailed planning and design of the test started with the beginning fiscal year 1996. The overall objective of the Single Heater Test was to gain an understanding of the coupled thermal, mechanical, hydrological, and chemical processes that are anticipated to occur in the local rock-mass in the potential repository as a result of heat from radioactive decay of the emplaced waste. This included making a priori predictions of the test results using existing models and subsequently refining or modifying the models, on the basis of comparative and interpretive analyses of the measurements and predictions. A second, no less important, objective was to try out, in a full-scale field setting, the various instruments and equipment to be employed in the future on a much larger, more complex, thermal test of longer duration, such as the Drift Scale Test. This ''shake down'' or trial aspect of the Single Heater Test applied

  17. SINGLE HEATER TEST FINAL REPORT

    International Nuclear Information System (INIS)

    J.B. Cho

    1999-01-01

    The Single Heater Test is the first of the in-situ thermal tests conducted by the U.S. Department of Energy as part of its program of characterizing Yucca Mountain in Nevada as the potential site for a proposed deep geologic repository for the disposal of spent nuclear fuel and high-level nuclear waste. The Site Characterization Plan (DOE 1988) contained an extensive plan of in-situ thermal tests aimed at understanding specific aspects of the response of the local rock-mass around the potential repository to the heat from the radioactive decay of the emplaced waste. With the refocusing of the Site Characterization Plan by the ''Civilian Radioactive Waste Management Program Plan'' (DOE 1994), a consolidated thermal testing program emerged by 1995 as documented in the reports ''In-Situ Thermal Testing Program Strategy'' (DOE 1995) and ''Updated In-Situ Thermal Testing Program Strategy'' (CRWMS M and O 1997a). The concept of the Single Heater Test took shape in the summer of 1995 and detailed planning and design of the test started with the beginning fiscal year 1996. The overall objective of the Single Heater Test was to gain an understanding of the coupled thermal, mechanical, hydrological, and chemical processes that are anticipated to occur in the local rock-mass in the potential repository as a result of heat from radioactive decay of the emplaced waste. This included making a priori predictions of the test results using existing models and subsequently refining or modifying the models, on the basis of comparative and interpretive analyses of the measurements and predictions. A second, no less important, objective was to try out, in a full-scale field setting, the various instruments and equipment to be employed in the future on a much larger, more complex, thermal test of longer duration, such as the Drift Scale Test. This ''shake down'' or trial aspect of the Single Heater Test applied not just to the hardware, but also to the teamwork and cooperation between

  18. Privilege as a Social Determinant of Health in Medical Education: A Single Class Session Can Change Privilege Perspective.

    Science.gov (United States)

    Witten, Nash A K; Maskarinec, Gregory G

    2015-09-01

    Accredited medical schools are required to prepare students to recognize the social determinants of health, such as privilege, yet privilege education has been overlooked in medical school curricula. The purpose of this study is to determine whether a single class session on privilege, within a social justice elective offered to first and second year medical students, is sufficient to change the perspective of medical students concerning their own personal privilege. A pre-class survey, followed by a class session on privilege, and post-class survey were conducted. Thirteen of the 18 students enrolled in the elective completed the pre-class survey. Ten students completed the post-class survey, although only 9 completed both the pre- and post-class surveys. The demographic profile of the participants was 93% Asian and 7% White ethnicity, with 57% identifying as being culturally American. There was no significant difference between average male and female or between age groups' self-assessed privilege amounts. For all characteristics tested, except hair color, participants had an increased self-assessed privilege perspective following the class. Three participants had an overall positive difference in privilege perspective, three participants had an overall negative difference in privilege perspective, and three participants had only a minimal change in privilege perspective. The absolute total difference in privilege perspective was 25 units of change. The single class session on privilege was sufficient to change significantly the perspective of medical students on their own personal privilege; however, future studies with larger groups of medical students are needed to elucidate other findings suggested by this study.

  19. Studying different tasks of implicit learning across multiple test sessions conducted on the web

    Directory of Open Access Journals (Sweden)

    Werner eSævland

    2016-06-01

    Full Text Available Implicit learning is usually studied through individual performance on a single task, with the most common tasks being Serial Reaction Time task (SRT; Nissen and Bullemer, 1987, Dynamic System Control task (DSC; (Berry and Broadbent, 1984 and artificial Grammar Learning task (AGL; (Reber, 1967. Few attempts have been made to compare performance across different implicit learning tasks within the same experiment. The current experiment was designed study the relationship between performance on the DSC Sugar factory task (Berry and Broadbent, 1984 and the Alternating Serial Reaction Time task (ASRT; (Howard and Howard, 1997. We also addressed another limitation to traditional implicit learning experiments, namely that implicit learning is usually studied in laboratory settings over a restricted time span lasting for less than an hour (Berry and Broadbent, 1984; Nissen and Bullemer, 1987; Reber, 1967. In everyday situations, implicit learning is assumed to involve a gradual accumulation of knowledge across several learning episodes over a larger time span (Norman and Price, 2012. One way to increase the ecological validity of implicit learning experiments could be to present the learning material repeatedly across shorter experimental sessions (Howard and Howard, 1997; Cleeremans and McClelland, 1991. This can most easily be done by using a web-based setup that participants can access from home. We therefore created an online web-based system for measuring implicit learning that could be administered in either single or multiple sessions. Participants (n = 66 were assigned to either a single-session or a multi-session condition. Learning and the degree of conscious awareness of the learned regularities was compared across condition (single vs. multiple sessions and tasks (DSC vs. ASRT. Results showed that learning on the two tasks was not related. However, participants in the multiple sessions condition did show greater improvements in reaction

  20. Auditory Cortex tACS and tRNS for Tinnitus: Single versus Multiple Sessions

    Directory of Open Access Journals (Sweden)

    Laura Claes

    2014-01-01

    Full Text Available Tinnitus is the perception of a sound in the absence of an external acoustic source, which often exerts a significant impact on the quality of life. Currently there is evidence that neuroplastic changes in both neural pathways are involved in the generation and maintaining of tinnitus. Neuromodulation has been suggested to interfere with these neuroplastic alterations. In this study we aimed to compare the effect of two upcoming forms of transcranial electrical neuromodulation: alternating current stimulation (tACS and random noise stimulation (tRNS, both applied on the auditory cortex. A database with 228 patients with chronic tinnitus who underwent noninvasive neuromodulation was retrospectively analyzed. The results of this study show that a single session of tRNS induces a significant suppressive effect on tinnitus loudness and distress, in contrast to tACS. Multiple sessions of tRNS augment the suppressive effect on tinnitus loudness but have no effect on tinnitus distress. In conclusion this preliminary study shows a possibly beneficial effect of tRNS on tinnitus and can be a motivation for future randomized placebo-controlled clinical studies with auditory tRNS for tinnitus. Auditory alpha-modulated tACS does not seem to be contributing to the treatment of tinnitus.

  1. Single event upset test programs

    International Nuclear Information System (INIS)

    Russen, L.C.

    1984-11-01

    It has been shown that the heavy ions in cosmic rays can give rise to single event upsets in VLSI random access memory devices (RAMs). Details are given of the programs written to test 1K, 4K, 16K and 64K memories during their irradiation with heavy charged ions, in order to simulate the effects of cosmic rays in space. The test equipment, which is used to load the memory device to be tested with a known bit pattern, and subsequently interrogate it for upsets, or ''flips'', is fully described. (author)

  2. Containing psychotic patients with fragile boundaries: a single-session group case study.

    Science.gov (United States)

    Lavarenne, Anaïs; Segal, Emily; Sigman, Maxine

    2013-01-01

    This case study describes a single group psychotherapy session of six individuals suffering from schizophrenia or schizoaffective illness, which was characterized by numerous manifestations of fragile Ego boundaries. Based on these illustrations of fragile Ego boundaries, we explore some of the group's core therapeutic actions against psychosis. We discuss how the group (1) provides access to a structuring auxiliary Ego, (2) acts as a containing object by establishing firm boundaries and by mentalizing patients' psychotic productions, and (3) may become a solid object representation introjected by individuals wrestling with porous Ego boundaries and a poor sense of self. We conclude that, in addition to the known role of group therapy in increasing mature defenses, developing insight and providing social support, the group promotes healthier Ego boundaries, and eventually improves self-differentiation, and also tolerance to interpersonal proximity. This case study clarifies group therapy dynamics with individuals suffering from psychosis.

  3. A single session of intraluminal brachytherapy in palliation of oesophageal cancer

    International Nuclear Information System (INIS)

    Jager, Jos; Langendijk, Hans; Pannebakker, Martin; Rijken, Joop; Jong, Jos de

    1995-01-01

    Between September 1987 and September 1993, 88 patients with oesophageal cancer were treated by a single session of intraluminal brachytherapy of 15 Gy prescribed at 1 cm distance from the central axis, using MDR 137 Cs (n 51) during the first part of the study and HDR 192 Ir (n = 37) during the second part of the study. All patients were regarded as inoperable. Improvement of dysphagia, assessed 4-6 weeks after treatment, was noted in 50 of 75 (67%) evaluable patients, whereas swallowing ability was completely restored in 47% of them. Relapse of dysphagia occurred in 28 (37%) patients during follow-up. Additional palliative treatment consisted of endoprosthesis in 14 (19%), a second course of brachytherapy in 13 (17%), one or more dilatations only in 11 (15%) and laser treatment in four (5%) patients. One non-fatal haemorrhage and five fistulae occurred, all in the presence of tumour. Two severe ulcerations without evidence of tumour were noted, both managed by combined curative treatment. The median survival of the group investigated was 5.5 months. An exophytic, non-circular growth pattern was associated with a better response. In a multivariate analysis the presence of distant metastases (p = 0.0028), weight loss (p = 0.0051) and an exophytic growth pattern (p = 0.0199) were associated with a worse survival. The present data indicate that a single session of ILB is appropriate in the palliation of dysphagia in patients with inoperable oesophagal cancer showing bad prognostic signs. Up to now there has been no clear evidence for benefit of addition of ERT

  4. Hemodynamic responses to single sessions of aerobic exercise and resistance exercise in pregnancy.

    Science.gov (United States)

    Petrov Fieril, Karolina; Glantz, Anna; Fagevik Olsen, Monika

    2016-09-01

    Previous research on maternal hemodynamic responses to a single exercise session during pregnancy is sparse, especially considering immediate responses to resistance exercise. The aim of the study was to examine blood pressure, heart rate, body temperature, and Rating of Perceived Exertion in healthy pregnant women during single sessions of continuous submaximal exercise in pregnancy week 21. A cross-over design was used. Twenty healthy pregnant women from four prenatal clinics in Gothenburg, Sweden, were included. On day 1, the women did 30 min of aerobic exercise and on day 3 they did 30 min of resistance exercise. Blood pressure, heart rate, and Rating of Perceived Exertion were measured after 15 and 30 min of exercise. After 15 and 30 min of exercise, there was a significant increase in systolic blood pressure and heart rate (p aerobic exercise (p = 0.01) than resistance exercise (p = 0.03). Resistance exercise was perceived as more intense than aerobic exercise after 15 min (p = 0.02) and 30 min (p = 0.001) of exercise. Five minutes after completing the exercise, blood pressure quickly reverted to normal although heart rate was still increased (p = 0.001). There was no correlation between heart rate and Rating of Perceived Exertion (rs  = 0.05-0.43). Maternal hemodynamic responses were essentially the same, regardless of whether the exercise was submaximal aerobic or resistance exercise, although resistance exercise was perceived as more intense. Aerobic and resistance exercise corresponding to "somewhat hard" seems to have no adverse effect with regard to maternal hemodynamic responses in healthy pregnancy. © 2016 Nordic Federation of Societies of Obstetrics and Gynecology.

  5. Efficacy of static stretching and proprioceptive neuromuscular facilitation stretch on hamstrings length after a single session.

    Science.gov (United States)

    O'Hora, John; Cartwright, Abigail; Wade, Clive D; Hough, Alan D; Shum, Gary L K

    2011-06-01

    A number of studies have investigated the efficacy of several repetitions of proprioceptive neuromuscular facilitation stretching (PNF) and static stretching (SS). However, there is limited research comparing the effects of a single bout of these stretching maneuvers. The aim of this study was to compare the effectiveness of a single bout of a therapist-applied 30-second SS vs. a single bout of therapist-applied 6-second hamstring (agonist) contract PNF. Forty-five healthy subjects between the ages of 21 and 35 were randomly allocated to 1 of the 2 stretching groups or a control group, in which no stretching was received. The flexibility of the hamstring was determined by a range of passive knee extension, measured using a universal goniometer, with the subject in the supine position and the hip at 90° flexion, before and after intervention. A significant increase in knee extension was found for both intervention groups after a single stretch (SS group = 7.53°, p < 0.01 and PNF group = 11.80°, p < 0.01). Both interventions resulted in a significantly greater increase in knee extension when compared to the control group (p < 0.01). The PNF group demonstrated significantly greater gains in knee extension compared to the SS group (mean difference 4.27°, p < 0.01). It can be concluded that a therapist applied SS or PNF results in a significant increase in hamstring flexibility. A hamstring (agonist) contract PNF is more effective than an SS in a single stretching session. These findings are important to physiotherapists or trainers working in clinical and sporting environments. Where in the past therapists may have spent time conducting multiple repetitions of a PNF and an SS, a single bout of either technique may be considered just as effective. A key component of the study methodology was the exclusion of a warm-up period before stretching. Therefore, the findings of efficacy of a single PNF are of particular relevance in sporting environments and busy clinical

  6. Does a single session of reading literary fiction prime enhanced mentalising performance? Four replication experiments of Kidd and Castano (2013).

    Science.gov (United States)

    Samur, Dalya; Tops, Mattie; Koole, Sander L

    2018-02-01

    Prior experiments indicated that reading literary fiction improves mentalising performance relative to reading popular fiction, non-fiction, or not reading. However, the experiments had relatively small sample sizes and hence low statistical power. To address this limitation, the present authors conducted four high-powered replication experiments (combined N = 1006) testing the causal impact of reading literary fiction on mentalising. Relative to the original research, the present experiments used the same literary texts in the reading manipulation; the same mentalising task; and the same kind of participant samples. Moreover, one experiment was pre-registered as a direct replication. In none of the experiments did reading literary fiction have any effect on mentalising relative to control conditions. The results replicate earlier findings that familiarity with fiction is positively correlated with mentalising. Taken together, the present findings call into question whether a single session of reading fiction leads to immediate improvements in mentalising.

  7. Hormonal, Metabolic and Cardiorespiratory Responses of Young and Adult Athletes to a Single Session of High Intensity Cycle Exercise

    OpenAIRE

    Engel, Florian; Härtel, Sascha; Wagner, Matthias Oliver; Strahler, Jana; Bös, Klaus; Sperlich, Billy

    2014-01-01

    This study aimed to determine the effects of a single High Intensity Interval Training (HIIT) session on salivary cortisol (SC) levels, physiological responses and performance in trained boys and men. Twenty-three boys (11.5±0.8 years) and 25 men (29.7±4.6 years) performed HIIT (four consecutive Wingate Anaerobic Tests). SC in boys and men increased after HIIT from 5.55±3.3 nmol/l to 15.13±9.7 nmol/l (+173%) and from 7.07±4.7 nmol/l to 19.19±12.7 nmol/l (+171%), respectively (p

  8. Can a single session of motor imagery promote motor learning of locomotion in older adults? A randomized controlled trial

    Directory of Open Access Journals (Sweden)

    Nicholson VP

    2018-04-01

    Full Text Available Vaughan P Nicholson,1 Justin WL Keogh,2–4 Nancy L Low Choy1 1School of Physiotherapy, Australian Catholic University, Brisbane, QLD, Australia; 2Faculty of Health Sciences and Medicine, Bond University, Robina, QLD, Australia; 3Human Potential Centre, AUT University, Auckland, New Zealand; 4Cluster for Health Improvement, Faculty of Science, Health, Education and Engineering, University of the Sunshine Coast, Sunshine Coast, QLD, Australia Purpose: To investigate the influence of a single session of locomotor-based motor imagery training on motor learning and physical performance. Patients and methods: Thirty independent adults aged >65 years took part in the randomized controlled trial. The study was conducted within an exercise science laboratory. Participants were randomly divided into three groups following baseline locomotor testing: motor imagery training, physical training, and control groups. The motor imagery training group completed 20 imagined repetitions of a locomotor task, the physical training group completed 20 physical repetitions of a locomotor task, and the control group spent 25 minutes playing mentally stimulating games on an iPad. Imagined and physical performance times were measured for each training repetition. Gait speed (preferred and fast, timed-up-and-go, gait variability and the time to complete an obstacle course were completed before and after the single training session. Results: Motor learning occurred in both the motor imagery training and physical training groups. Motor imagery training led to refinements in motor planning resulting in imagined movements better matching the physically performed movement at the end of training. Motor imagery and physical training also promoted improvements in some locomotion outcomes as demonstrated by medium to large effect size improvements after training for fast gait speed and timed-up-and-go. There were no training effects on gait variability. Conclusion: A single session

  9. A single aerobic exercise session accelerates movement execution but not central processing.

    Science.gov (United States)

    Beyer, Kit B; Sage, Michael D; Staines, W Richard; Middleton, Laura E; McIlroy, William E

    2017-03-27

    Previous research has demonstrated that aerobic exercise has disparate effects on speed of processing and movement execution. In simple and choice reaction tasks, aerobic exercise appears to increase speed of movement execution while speed of processing is unaffected. In the flanker task, aerobic exercise has been shown to reduce response time on incongruent trials more than congruent trials, purportedly reflecting a selective influence on speed of processing related to cognitive control. However, it is unclear how changes in speed of processing and movement execution contribute to these exercise-induced changes in response time during the flanker task. This study examined how a single session of aerobic exercise influences speed of processing and movement execution during a flanker task using electromyography to partition response time into reaction time and movement time, respectively. Movement time decreased during aerobic exercise regardless of flanker congruence but returned to pre-exercise levels immediately after exercise. Reaction time during incongruent flanker trials decreased over time in both an aerobic exercise and non-exercise control condition indicating it was not specifically influenced by exercise. This disparate influence of aerobic exercise on movement time and reaction time indicates the importance of partitioning response time when examining the influence of aerobic exercise on speed of processing. The decrease in reaction time over time independent of aerobic exercise indicates that interpreting pre-to-post exercise changes in behavior requires caution. Copyright © 2017 IBRO. Published by Elsevier Ltd. All rights reserved.

  10. Effects of one session radial extracorporeal shockwave therapy on post-stroke plantarflexor spasticity: a single-blind clinical trial.

    Science.gov (United States)

    Radinmehr, Hojjat; Nakhostin Ansari, Noureddin; Naghdi, Soofia; Olyaei, Gholamreza; Tabatabaei, Azadeh

    2017-03-01

    Purpose To examine the effects of radial extracorporeal shockwave therapy (rESWT) on plantarflexor spasticity after stroke. Method Twelve patients with stroke were randomly included for this prospective, single-blind clinical trial. Patients received one rESWT session (0.340 mJ/mm 2 , 2000 shots) on plantarflexor muscle. The Modified Modified Ashworth Scale (MMAS), H-reflex tests, ankle range of motion (ROM), passive plantarflexor torque (PPFT) and timed up and go test (TUG) were measured at baseline (T 0 ), immediately after treatment (T 1 ) and one hour after the end of the treatment (T 2 ). Results Patients had improved the MMAS scores for both the gastrocnemius and the soleus muscles, active and passive ROM, PPFT and TUG over time after rESWT. For the PPFT, it was greater at high velocity than at low velocity, and there was a significant three-way interaction between time, knee position (extended/flexed) and velocity (low/high). The H-reflex latency had decreased at T 1 , but there was no significant effect on H max /M max ratio. Conclusions The rESWT improved plantarflexor spasticity, and the effects sustained for one hour, whereas it was not effective in improving spinal excitability. Implications for Rehabilitation One session radial extracorporeal shock wave therapy (rESWT) is safe and effective in improving post stroke plantarflexor spasticity, ankle active and passive range of motion, passive torque, and walking capability. The spasticity scores improved for both the gastrocnemius and the soleus muscles and persisted one hour after rESWT. The magnitude of resistive plantarflexor passive torque in the knee extended position and high velocity was larger over time suggesting greater gastrocnemius spasticity than soleus. The rESWT had no significant effects on alpha motorneuron excitability.

  11. The Concept of a Single-sex Optional Discussion Session in Introductory Astronomy at a Publicly Funded University

    Science.gov (United States)

    Shawl, S.

    1996-12-01

    The concept of single-sex education for science and mathematics has recently received renewed discussion in both the popular and professional literature. So important is the topic within higher education that the Duke Journal of Gender Law and Policy sponsored a symposium called "Gender & The Higher Education Classroom: Maximizing the Learning Environment" in February 1996 (http://www.duke.edu/ jrd4/djgcnf96.htm). The concept is especially controversial in publicly supported educational institutions. The idea of offering an optional discussion session limited to a single sex in a university-level introductory astronomy course at a State-supported school was considered through discussions with a number of faculty and administrators, and through a questionnaire aimed at determining student attitudes toward the concept. The results of the student questionnaire will be presented. (While the questionnaire results will be seen to be in favor of such an optional discussion session, such sessions have not been offered.)

  12. Assessment test before the reporting phase of tutorial session in problem-based learning.

    Science.gov (United States)

    Bestetti, Reinaldo B; Couto, Lucélio B; Restini, Carolina Ba; Faria, Milton; Romão, Gustavo S

    2017-01-01

    In our context, problem-based learning is not used in the preuniversity environment. Consequently, students have a great deal of difficulty adapting to this method, particularly regarding self-study before the reporting phase of a tutorial session. Accordingly, the aim of this study was to assess if the application of an assessment test (multiple choice questions) before the reporting phase of a tutorial session would improve the academic achievement of students at the preclinical stage of our medical course. A test consisting of five multiple choice questions, prepared by tutors of the module at hand and related to the problem-solving process of each tutorial session, was applied following the self-study phase and immediately before the reporting phase of all tutorial sessions. The questions were based on the previously established student learning goals. The assessment was applied to all modules from the fifth to the eighth semesters. The final scores achieved by students in the end-of-module tests were compared. Overall, the mean test score was 65.2±0.7% before and 68.0±0.7% after the introduction of an assessment test before the reporting phase ( P 0.05). Students in the eighth semester scored 71.8±2.3% compared to 70±2% when they were in the seventh semester ( P >0.05). In our medical course, the application of an assessment test (a multiple choice test) before the reporting phase of the problem-based learning tutorial process increases the overall academic achievement of students, especially of those in the sixth semester in comparison with when they were in the fifth semester.

  13. Single Session Web-Based Counselling: A Thematic Analysis of Content from the Perspective of the Client

    Science.gov (United States)

    Rodda, S. N.; Lubman, D. I.; Cheetham, A.; Dowling, N. A.; Jackson, A. C.

    2015-01-01

    Despite the exponential growth of non-appointment-based web counselling, there is limited information on what happens in a single session intervention. This exploratory study, involving a thematic analysis of 85 counselling transcripts of people seeking help for problem gambling, aimed to describe the presentation and content of online…

  14. Lymphocyte Redox Imbalance and Reduced Proliferation after a Single Session of High Intensity Interval Exercise.

    Science.gov (United States)

    Tossige-Gomes, Rosalina; Costa, Karine Beatriz; Ottone, Vinícius de Oliveira; Magalhães, Flávio de Castro; Amorim, Fabiano Trigueiro; Rocha-Vieira, Etel

    2016-01-01

    This study investigated whether an acute session of high-intensity interval training (HIIT) is sufficient to alter lymphocyte function and redox status. Sixteen young healthy men underwent a HIIT session on a cycloergometer, consisting of eight bouts of 1 min at 90-100% of peak power, with 75 seconds of active recovery at 30 W between bouts. Venous blood was collected before, immediately after, and 30 minutes after the HIIT session. In response to Staphylococcus aureus superantigen B (SEB) stimulation, lymphocyte proliferation decreased and the IL-2 concentration increased after the HIIT session. However, the HIIT session had no effect on lymphocyte proliferation or IL-2 response to phytohemagglutinin stimulation. The HIIT session also induced lymphocyte redox imbalance, characterized by an increase in the concentration of thiobarbituric acid reactive substances and a decrease in the activity of the antioxidant enzyme catalase. Lymphocyte viability was not affected by the HIIT session. The frequencies of CD25+ and CD69+ T helper and B lymphocytes in response to superantigen stimulation were lower after exercise, suggesting that superantigen-induced lymphocyte activation was reduced by HIIT. However, HIIT also led to a reduction in the frequency of CD4+ and CD19+ cells, so the frequencies of CD25+ and CD69+ cells within the CD4 and CD19 cell populations were not affected by HIIT. These data indicate that the reduced lymphocyte proliferation observed after HIIT is not due to reduced early lymphocyte activation by superantigen. Our findings show that an acute HIIT session promotes lymphocyte redox imbalance and reduces lymphocyte proliferation in response to superantigenic, but not to mitogenic stimulation. This observation cannot be explained by alteration of the early lymphocyte activation response to superantigen. The manner in which lymphocyte function modulation by an acute HIIT session can affect individual immunity and susceptibility to infection is important

  15. Lymphocyte Redox Imbalance and Reduced Proliferation after a Single Session of High Intensity Interval Exercise.

    Directory of Open Access Journals (Sweden)

    Rosalina Tossige-Gomes

    Full Text Available This study investigated whether an acute session of high-intensity interval training (HIIT is sufficient to alter lymphocyte function and redox status. Sixteen young healthy men underwent a HIIT session on a cycloergometer, consisting of eight bouts of 1 min at 90-100% of peak power, with 75 seconds of active recovery at 30 W between bouts. Venous blood was collected before, immediately after, and 30 minutes after the HIIT session. In response to Staphylococcus aureus superantigen B (SEB stimulation, lymphocyte proliferation decreased and the IL-2 concentration increased after the HIIT session. However, the HIIT session had no effect on lymphocyte proliferation or IL-2 response to phytohemagglutinin stimulation. The HIIT session also induced lymphocyte redox imbalance, characterized by an increase in the concentration of thiobarbituric acid reactive substances and a decrease in the activity of the antioxidant enzyme catalase. Lymphocyte viability was not affected by the HIIT session. The frequencies of CD25+ and CD69+ T helper and B lymphocytes in response to superantigen stimulation were lower after exercise, suggesting that superantigen-induced lymphocyte activation was reduced by HIIT. However, HIIT also led to a reduction in the frequency of CD4+ and CD19+ cells, so the frequencies of CD25+ and CD69+ cells within the CD4 and CD19 cell populations were not affected by HIIT. These data indicate that the reduced lymphocyte proliferation observed after HIIT is not due to reduced early lymphocyte activation by superantigen. Our findings show that an acute HIIT session promotes lymphocyte redox imbalance and reduces lymphocyte proliferation in response to superantigenic, but not to mitogenic stimulation. This observation cannot be explained by alteration of the early lymphocyte activation response to superantigen. The manner in which lymphocyte function modulation by an acute HIIT session can affect individual immunity and susceptibility to

  16. Test-Retest Reliability of Measures Commonly Used to Measure Striatal Dysfunction across Multiple Testing Sessions: A Longitudinal Study.

    Science.gov (United States)

    Palmer, Clare E; Langbehn, Douglas; Tabrizi, Sarah J; Papoutsi, Marina

    2017-01-01

    Cognitive impairment is common amongst many neurodegenerative movement disorders such as Huntington's disease (HD) and Parkinson's disease (PD) across multiple domains. There are many tasks available to assess different aspects of this dysfunction, however, it is imperative that these show high test-retest reliability if they are to be used to track disease progression or response to treatment in patient populations. Moreover, in order to ensure effects of practice across testing sessions are not misconstrued as clinical improvement in clinical trials, tasks which are particularly vulnerable to practice effects need to be highlighted. In this study we evaluated test-retest reliability in mean performance across three testing sessions of four tasks that are commonly used to measure cognitive dysfunction associated with striatal impairment: a combined Simon Stop-Signal Task; a modified emotion recognition task; a circle tracing task; and the trail making task. Practice effects were seen between sessions 1 and 2 across all tasks for the majority of dependent variables, particularly reaction time variables; some, but not all, diminished in the third session. Good test-retest reliability across all sessions was seen for the emotion recognition, circle tracing, and trail making test. The Simon interference effect and stop-signal reaction time (SSRT) from the combined-Simon-Stop-Signal task showed moderate test-retest reliability, however, the combined SSRT interference effect showed poor test-retest reliability. Our results emphasize the need to use control groups when tracking clinical progression or use pre-baseline training on tasks susceptible to practice effects.

  17. SU-F-J-110: MRI-Guided Single-Session Simulation, Online Adaptation, and Treatment

    International Nuclear Information System (INIS)

    Hill, P; Geurts, M; Mittauer, K; Bayouth, J

    2016-01-01

    Purpose: To develop a combined simulation and treatment workflow for MRI-guided radiation therapy using the ViewRay treatment planning and delivery system. Methods: Several features of the ViewRay MRIdian planning and treatment workflows are used to simulate and treat patients that require emergent radiotherapy. A simple “pre-plan” is created on diagnostic imaging retrieved from radiology PACS, where conformal fields are created to target a volume defined by a physician based on review of the diagnostic images and chart notes. After initial consult in radiation oncology, the patient is brought to the treatment room, immobilized, and imaged in treatment position with a volumetric MR. While the patient rests on the table, the pre-plan is applied to the treatment planning MR and dose is calculated in the treatment geometry. After physician review, modification of the plan may include updating the target definition, redefining fields, or re-balancing beam weights. Once an acceptable treatment plan is finalized and approved, the patient is treated. Results: Careful preparation and judicious choices in the online planning process allow conformal treatment plans to be created and delivered in a single, thirty-minute session. Several advantages have been identified using this process as compared to conventional urgent CT simulation and delivery. Efficiency gains are notable, as physicians appreciate the predictable time commitment and patient waiting time for treatment is decreased. MR guidance in a treatment position offers both enhanced contrast for target delineation and reduction of setup uncertainties. The MRIdian system tools designed for adaptive radiotherapy are particularly useful, enabling plan changes to be made in minutes. Finally, the resulting plans, typically 6 conformal beams, are delivered as quickly as more conventional AP/PA beam arrangements with comparatively superior dose distributions. Conclusion: The ViewRay treatment planning software and

  18. Effect of a single-session meditation training to reduce stress and improve quality of life among health care professionals: a "dose-ranging" feasibility study.

    Science.gov (United States)

    Prasad, Kavita; Wahner-Roedler, Dietlind L; Cha, Stephen S; Sood, Amit

    2011-01-01

    The primary aim of the study was to assess the feasibility of incorporating a single-session meditation-training program into the daily activities of healthy employees of a tertiary-care academic medical center. The study also assessed the most preferred duration of meditation and the effect of the meditation program on perceived stress, anxiety, and overall quality of life (QOL). Seventeen healthy clinic employees were recruited for this study. After an initial group instruction session covering basic information about meditation, Paced Breathing Meditation (PBM) was taught to the participants. Participants were instructed to self-practice meditation with the help of a DVD daily for a total of 4 weeks. The DVD had three different programs of 5, 15, and 30 minutes with a menu option to choose one of the programs. (1) Patient diary, (2) Perceived Stress Scale (PSS), (3) Linear Analogue Self-Assessment (LASA), (4) Smith Anxiety Scale (SAS). Primary outcome measures were compared using the paired t-test. All participants were female; median age was 48 years (range 33-60 y). The 5-minute meditation session was practiced by 14 participants a total of 137 times during the 4-week trial period, the 15-minute session by 16 participants a total of 223 times, and the 30-minute session by 13 participants 71 times. The median number of days practiced was 25 (range 10-28 d); the average total time practiced was 394 minutes (range 55-850 min). After 4 weeks of practice, the scores of the following instruments improved significantly from baseline: PSS (P meditation in a single training session to health care employees. The study shows that 15 minutes once or twice a day is the most feasible duration of meditation practice. The study also provides promising preliminary efficacy data of this program for improving stress, anxiety, and QOL.

  19. Proceedings of the Third NRC/ASME Symposium on Valve and Pump Testing. Session 1A--Session 2C: Volume 1

    Energy Technology Data Exchange (ETDEWEB)

    1994-07-01

    The 1994 Symposium on Valve and Pump Testing, jointly sponsored by the Board of Nuclear Codes and Standards of the American Society of Mechanical Engineers and by the Nuclear Regulatory Commission, provides a forum for the discussion of current programs and methods for inservice testing and motor-operated valve testing at nuclear power plants. The symposium also provides an opportunity to discuss the need to improve that testing in order to help ensure the reliable performance of pumps and valves. The participation of industry representatives, regulators, and consultants results in the discussion of a broad spectrum of ideas and perspectives regarding the improvement of inservice testing of pumps and valves at nuclear power plants. This document, Volume 1, covers sessions 1A through session 2C. The individual papers have been cataloged separately.

  20. Proceedings of the Third NRC/ASME Symposium on Valve and Pump Testing. Session 1A--Session 2C: Volume 1

    International Nuclear Information System (INIS)

    1994-07-01

    The 1994 Symposium on Valve and Pump Testing, jointly sponsored by the Board of Nuclear Codes and Standards of the American Society of Mechanical Engineers and by the Nuclear Regulatory Commission, provides a forum for the discussion of current programs and methods for inservice testing and motor-operated valve testing at nuclear power plants. The symposium also provides an opportunity to discuss the need to improve that testing in order to help ensure the reliable performance of pumps and valves. The participation of industry representatives, regulators, and consultants results in the discussion of a broad spectrum of ideas and perspectives regarding the improvement of inservice testing of pumps and valves at nuclear power plants. This document, Volume 1, covers sessions 1A through session 2C. The individual papers have been cataloged separately

  1. LED session prior incremental step test enhance VO2maxin running.

    Science.gov (United States)

    Mezzaroba, Paulo V; Pessôa Filho, Dalton M; Zagatto, Alessandro M; Machado, Fabiana Andrade

    2018-03-15

    This study aimed to investigate the effect of prior LED sessions on the responses of cardiorespiratory parameters during the running incremental step test. Twenty-six healthy, physically active, young men, aged between 20 and 30 years, took part in this study. Participants performed two incremental load tests after placebo (PLA) and light-emitting diode application (LED), and had their gas exchange, heart rate (HR), blood lactate, and rating of perceived exertion (RPE) monitored during all tests. The PLA and LED conditions were compared using the dependent Student t test with significance set at 5%. The T test showed higher maximum oxygen uptake (VO 2max ) (PLA = 47.2 ± 5.7; LED = 48.0 ± 5.4 ml kg -1  min -1 , trivial effect size), peak velocity (V peak ) (PLA = 13.4 ± 1.2; LED = 13.6 ± 1.2 km h -1 , trivial effect size), and lower maximum HR (PLA = 195.3 ± 3.4; LED = 193.3 ± 3.9 b min -1 , moderate effect size) for LED compared to PLA conditions. Furthermore, submaximal values of HR and RPE were lower, and submaximal VO 2 values were higher when LED sessions prior to the incremental step test were applied. A positive response of the previous LED application in the blood lactate disappearance was also demonstrated, especially 13 and 15 min after the test. It is concluded that LED sessions prior to exercise modify cardiorespiratory response by affecting running tolerance during the incremental step test, metabolite clearance, and RPE. Therefore, LED could be used as a prior exercise strategy to modulate oxidative response acutely in targeted muscle and enhance exercise tolerance.

  2. Effect of a single session of aerobic walking exercise on arterial pressure in community-living elderly individuals.

    Science.gov (United States)

    Lima, Leandra G; Moriguti, Júlio C; Ferriolli, Eduardo; Lima, Nereida K C

    2012-04-01

    Several studies have demonstrated that one exercise session (ES) on a cycloergometer or ergometric treadmill causes a reduction in blood pressure (BP). However, there are few similar studies on walking, which is the exercise modality most available to the elderly. We investigated the immediate and 24-h effects of walking on BP in independent, community-living elderly individuals. Volunteers participated in a single ES and resting control session (CS). Before and after each session, BP was measured by auscultatory and oscillometric methods. After each session, 24-h ambulatory blood pressure monitoring was conducted. An accelerometer was installed 48 h before the sessions and left in place for 5 days. The mean volunteer age was 67.7±3.5 years; 11 were hypertensive patients under treatment, and 12 were normotensive. In the total sample, there were immediate 14mm Hg and 12 mm Hg reductions in systolic BP (SBP) after the ES according to the auscultatory and oscillometric methods, respectively. Diastolic BP (DBP) was reduced by 4 mm Hg after the ES according to both methods. SBP during wakefulness and sleep and DBP during wakefulness were lower after the ES than after the CS (Psleep were determined individually (variable-time pattern) using data from the activity monitors and provided by the volunteers. The variable-time pattern was more effective in detecting reductions in BP than the fixed-time pattern.

  3. Does Gender Influence Electroconvulsive Therapy Sessions Required across Psychiatric Diagnoses? A 5-Year Experience from a Single Center

    Science.gov (United States)

    Manohar, Harshini; Subramanian, Karthick; Menon, Vikas; Kattimani, Shivanand

    2017-01-01

    Context: There is a paucity of systematic data reflecting the practice of electroconvulsive therapy (ECT) from developing countries. Aim: We aimed to identify the number of ECT sessions required to yield response and gender diffeferences in the number of sessions across various diagnostic categories. Setting and Design: A record-based study from a teaching cum tertiary care hospital in South India. Subjects and Methods: Case records of patients who received modified ECT from January 2011 to January 2016 were reviewed. The sociodemographic details and ECT-related data were collected. Psychiatric diagnoses were ascertained as per the International Classification of Diseases, 10th Revision criteria. Statistical Analysis Used: Kruskal–Wallis test and Mann–Whitney U-test. Results: Among 148 patients, 82 (55.4%) had mood disorder (bipolar disorder and recurrent depressive disorder), 43 (29.1%) had schizophrenia, and 22 (14.9%) had other acute and transient psychotic disorders (ATPDs). Patients with mood disorders, schizophrenia, and other ATPD received 7.3 (± 3.8), 9.7 (± 6.1), and 5.4 (± 2.0) ECT sessions, respectively, to achieve response. There was no gender difference in the number of sessions received. Conclusion: Our findings show that number of ECT sessions required to yield response may be disorder-specific. Gender does not influence the ECT dose requirement. Variations in ECT parameters across settings may limit the generalizability of results. PMID:28694625

  4. A single session of meditation reduces of physiological indices of anger in both experienced and novice meditators.

    Science.gov (United States)

    Fennell, Alexander B; Benau, Erik M; Atchley, Ruth Ann

    2016-02-01

    The goal of the present study was to explore how anger reduction via a single session of meditation might be measured using psychophysiological methodologies. To achieve this, 15 novice meditators (Experiment 1) and 12 practiced meditators (Experiment 2) completed autobiographical anger inductions prior to, and following, meditation training while respiration rate, heart rate, and blood pressure were measured. Participants also reported subjective anger via a visual analog scale. At both stages, the experienced meditators' physiological reaction to the anger induction reflected that of relaxation: slowed breathing and heart rate and decreased blood pressure. Naïve meditators exhibited physiological reactions that were consistent with anger during the pre-meditation stage, while after meditation training and a second anger induction they elicited physiological evidence of relaxation. The current results examining meditation training show that the naïve group's physiological measures mimicked those of the experienced group following a single session of meditation training. Copyright © 2016. Published by Elsevier Inc.

  5. Single-Session Alcohol Interventions for Heavy Drinking College Students: A Systematic Review and Meta-Analysis.

    Science.gov (United States)

    Samson, Jennifer E; Tanner-Smith, Emily E

    2015-07-01

    The purpose of this study was to conduct a meta-analysis summarizing the effectiveness of brief, single-session interventions to reduce alcohol use among heavy drinking college students. A comprehensive literature search identified 73 studies comparing the effects of single-session brief alcohol intervention with treatment-as-usual or no-treatment control conditions on alcohol use among heavy drinking college students. Random-effects meta-analyses with robust variance estimates were used to synthesize 662 effect sizes, estimating the average overall effect of the interventions and the variability in effects across a range of moderators. An overall mean effect size of ḡ = 0.18, 95% CI [0.12, 0.24] indicated that, on average, single-session brief alcohol interventions significantly reduced alcohol use among heavy drinking college students relative to comparison conditions. There was minimal variability in effects associated with study method and quality, general study characteristics, participant demographics, or outcome measure type. However, studies using motivational enhancement therapy/motivational interviewing (MET/MI) modalities reported larger effects than those using psychoeducational therapy (PET) interventions. Further investigation revealed that studies using MET/ MI and feedback-only interventions, but not those using cognitive-behavioral therapy or PET modalities, reported average effect sizes that differed significantly from zero. There was also evidence that long-term effects were weaker than short-term effects. Single-session brief alcohol interventions show modest effects for reducing alcohol consumption among heavy drinking college students and may be particularly effective when they incorporate MET/MI principles. More research is needed to directly compare intervention modalities, to develop more potent interventions, and to explore the persistence of long-term effects.

  6. Use of GPS TEC Maps for Calibrating Single Band VLBI Sessions

    Science.gov (United States)

    Gordon, David

    2010-01-01

    GPS TEC ionosphere maps were first applied to a series of K and Q band VLBA astrometry sessions to try to eliminate a declination bias in estimated source positions. Their usage has been expanded to calibrate X-band only VLBI observations as well. At K-band, approx.60% of the declination bias appears to be removed with the application of GPS ionosphere calibrations. At X-band however, it appears that up to 90% or more of the declination bias is removed, with a corresponding increase in RA and declination uncertainties of approx.0.5 mas. GPS ionosphere calibrations may be very useful for improving the estimated positions of the X-only and S-only sources in the VCS and RDV sessions.

  7. The Shock and Vibration Bulletin. Part 2. Opening Session, Panel Session, Shock Testing and Analysis, Fluid-structure Topics

    Science.gov (United States)

    1976-08-01

    have control over us operational test and evaluacion . are dead serious about OT&E. The impact of these chan es upon And third, what we’re talking about...they were to try to get tions, which we have seen in social problems in 20 to 40 thousand hours of MTBF all the money the last few years. I hope there

  8. All-in-one interictal presurgical imaging in patients with epilepsy: single-session EEG/PET/(f)MRI

    International Nuclear Information System (INIS)

    Grouiller, Frederic; Delattre, Benedicte M.A.; Lazeyras, Francois; Ratib, Osman; Vargas, Maria I.; Garibotto, Valentina; Pittau, Francesca; Spinelli, Laurent; Seeck, Margitta; Vulliemoz, Serge; Heinzer, Susanne; Iannotti, Giannina R.

    2015-01-01

    In patients with pharmacoresistant focal epilepsy, resection of the epileptic focus can lead to freedom from seizures or significant improvement in well-selected candidates. Localization of the epileptic focus with multimodal concordance is crucial for a good postoperative outcome. Beyond the detection of epileptogenic lesions on structural MRI and focal hypometabolism on FDG PET, EEG-based Electric Source Imaging (ESI) and simultaneous EEG and functional MRI (EEG-fMRI) are increasingly applied for mapping epileptic activity. We here report presurgical multimodal interictal imaging using a hybrid PET/MR scanner for single-session FDG PET, MRI, EEG-fMRI and ESI. This quadrimodal imaging procedure was performed in a single session in 12 patients using a high-density (256 electrodes) MR-compatible EEG system and a hybrid PET/MR scanner. EEG was used to exclude subclinical seizures during uptake of the PET tracer, to compute ESI on interictal epileptiform discharges and to guide fMRI analysis for mapping haemodynamic changes correlated with interictal epileptiform activity. The whole multimodal recording was performed in less than 2 hours with good patient comfort and data quality. Clinically contributory examinations with at least two modalities were obtained in nine patients and with all modalities in five patients. This single-session quadrimodal imaging procedure provided reliable and contributory interictal clinical data. This procedure avoids multiple scanning sessions and is associated with less radiation exposure than PET-CT. Moreover, it guarantees the same medication level and medical condition for all modalities. The procedure improves workflow and could reduce the duration and cost of presurgical epilepsy evaluations. (orig.)

  9. All-in-one interictal presurgical imaging in patients with epilepsy: single-session EEG/PET/(f)MRI.

    Science.gov (United States)

    Grouiller, Frédéric; Delattre, Bénédicte M A; Pittau, Francesca; Heinzer, Susanne; Lazeyras, François; Spinelli, Laurent; Iannotti, Giannina R; Seeck, Margitta; Ratib, Osman; Vargas, Maria I; Garibotto, Valentina; Vulliemoz, Serge

    2015-06-01

    In patients with pharmacoresistant focal epilepsy, resection of the epileptic focus can lead to freedom from seizures or significant improvement in well-selected candidates. Localization of the epileptic focus with multimodal concordance is crucial for a good postoperative outcome. Beyond the detection of epileptogenic lesions on structural MRI and focal hypometabolism on FDG PET, EEG-based Electric Source Imaging (ESI) and simultaneous EEG and functional MRI (EEG-fMRI) are increasingly applied for mapping epileptic activity. We here report presurgical multimodal interictal imaging using a hybrid PET/MR scanner for single-session FDG PET, MRI, EEG-fMRI and ESI. This quadrimodal imaging procedure was performed in a single session in 12 patients using a high-density (256 electrodes) MR-compatible EEG system and a hybrid PET/MR scanner. EEG was used to exclude subclinical seizures during uptake of the PET tracer, to compute ESI on interictal epileptiform discharges and to guide fMRI analysis for mapping haemodynamic changes correlated with interictal epileptiform activity. The whole multimodal recording was performed in less than 2 hours with good patient comfort and data quality. Clinically contributory examinations with at least two modalities were obtained in nine patients and with all modalities in five patients. This single-session quadrimodal imaging procedure provided reliable and contributory interictal clinical data. This procedure avoids multiple scanning sessions and is associated with less radiation exposure than PET-CT. Moreover, it guarantees the same medication level and medical condition for all modalities. The procedure improves workflow and could reduce the duration and cost of presurgical epilepsy evaluations.

  10. All-in-one interictal presurgical imaging in patients with epilepsy: single-session EEG/PET/(f)MRI

    Energy Technology Data Exchange (ETDEWEB)

    Grouiller, Frederic; Delattre, Benedicte M.A.; Lazeyras, Francois; Ratib, Osman; Vargas, Maria I.; Garibotto, Valentina [Geneva University Hospital, Department of Radiology and Medical Informatics, Geneva 14 (Switzerland); Pittau, Francesca; Spinelli, Laurent; Seeck, Margitta; Vulliemoz, Serge [Geneva University Hospital, EEG and Epilepsy Unit, Department of Neurology, Geneva 14 (Switzerland); Heinzer, Susanne [Philips AG Healthcare, Zuerich (Switzerland); Iannotti, Giannina R. [Geneva University Hospital, Functional Brain Mapping Laboratory, Department of Fundamental Neurosciences, Geneva 14 (Switzerland)

    2015-04-17

    In patients with pharmacoresistant focal epilepsy, resection of the epileptic focus can lead to freedom from seizures or significant improvement in well-selected candidates. Localization of the epileptic focus with multimodal concordance is crucial for a good postoperative outcome. Beyond the detection of epileptogenic lesions on structural MRI and focal hypometabolism on FDG PET, EEG-based Electric Source Imaging (ESI) and simultaneous EEG and functional MRI (EEG-fMRI) are increasingly applied for mapping epileptic activity. We here report presurgical multimodal interictal imaging using a hybrid PET/MR scanner for single-session FDG PET, MRI, EEG-fMRI and ESI. This quadrimodal imaging procedure was performed in a single session in 12 patients using a high-density (256 electrodes) MR-compatible EEG system and a hybrid PET/MR scanner. EEG was used to exclude subclinical seizures during uptake of the PET tracer, to compute ESI on interictal epileptiform discharges and to guide fMRI analysis for mapping haemodynamic changes correlated with interictal epileptiform activity. The whole multimodal recording was performed in less than 2 hours with good patient comfort and data quality. Clinically contributory examinations with at least two modalities were obtained in nine patients and with all modalities in five patients. This single-session quadrimodal imaging procedure provided reliable and contributory interictal clinical data. This procedure avoids multiple scanning sessions and is associated with less radiation exposure than PET-CT. Moreover, it guarantees the same medication level and medical condition for all modalities. The procedure improves workflow and could reduce the duration and cost of presurgical epilepsy evaluations. (orig.)

  11. Single High Intensity Focused Ultrasound Session as a Whole Gland Primary Treatment for Clinically Localized Prostate Cancer: 10-Year Outcomes

    Directory of Open Access Journals (Sweden)

    Ksenija Limani

    2014-01-01

    Full Text Available Objectives. To assess the treatment outcomes of a single session of whole gland high intensity focused ultrasound (HIFU for patients with localized prostate cancer (PCa. Methods. Response rates were defined using the Stuttgart and Phoenix criteria. Complications were graded according to the Clavien score. Results. At a median follow-up of 94months, 48 (44.4% and 50 (46.3% patients experienced biochemical recurrence for Phoenix and Stuttgart definition, respectively. The 5- and 10-year actuarial biochemical recurrence free survival rates were 57% and 40%, respectively. The 10-year overall survival rate, cancer specific survival rate, and metastasis free survival rate were 72%, 90%, and 70%, respectively. Preoperative high risk category, Gleason score, preoperative PSA, and postoperative nadir PSA were independent predictors of oncological failure. 24.5% of patients had self-resolving LUTS, 18.2% had urinary tract infection, and 18.2% had acute urinary retention. A grade 3b complication occurred in 27 patients. Pad-free continence rate was 87.9% and the erectile dysfunction rate was 30.8%. Conclusion. Single session HIFU can be alternative therapy for patients with low risk PCa. Patients with intermediate risk should be informed about the need of multiple sessions of HIFU and/or adjuvant treatments and HIFU performed very poorly in high risk patients.

  12. AN OVERVIEW OF TRAINING METHODS THAT PROMOTE THE HIGHEST LIPID OXIDATION DURING AND AFTER A SINGLE EXERCISE SESSION

    Directory of Open Access Journals (Sweden)

    Barbara Purkart

    2016-02-01

    Full Text Available Given that physical activity is the most effective way to increase lipid oxidation, its effects are influenced by several factors. The goal of this review was to identify the most effective methods that facilitate the highest lipid oxidation during and after a single exercise session. For this purpose, the available scientific literature was examined using PubMed, Web of Science, Google Scholar and Cochrane Library databases up to June 2013 with the following keywords: excess post exercise oxygen consumption, exercise fatty acid, energy expenditure exercise and interval training. From the identified 48,583 potentially relevant references, 172 of them met all the required criteria. It was found out that prolonged (> 30 min moderate intensity (55 − 70 % VO2max exercise such as walking, jogging or cycling is the most effective way to increase lipid oxidation during and after a single exercise session. Low-volume high-intensity interval exercise is supposed to be as effective as traditional exercise with continuous endurance, with the main effect on lipid oxidation after the session and similar long-term metabolic adaptations. However, more research is still needed to compare the effects of regular resistance exercise with traditional endurance and high-intensity interval exercise. Finally, nutrition is also a significant factor since food rich in fat and low in carbohydrates promotes greater lipid oxidation.

  13. Changes in Postural Sway After a Single Global Postural Reeducation Session in University Students: A Randomized Controlled Trial.

    Science.gov (United States)

    Lozano-Quijada, Carlos; Poveda-Pagán, Emilio J; Segura-Heras, José V; Hernández-Sánchez, Sergio; Prieto-Castelló, María J

    2017-09-01

    The purpose of this study was to assess the effectiveness of a single session of global postural reeducation (GPR) in postural sway in young adult university students who use data visualization screens. A randomized controlled trial with 2 parallel groups was performed. Sixty-four subjects were randomized in the experimental group (12 men and 20 women) who underwent the GPR session, and a control group (13 men and 19 women) that did not receive any intervention was included. Center of pressure (COP) was assessed using a stabilometric platform, with eyes open and eyes closed before, immediately after, 48 hours after, and 7 days after intervention in both groups. In the interaction of time and gender, statistically significant differences were found for the area covered by COP (P = .020) and for the standard deviation (SD) in the mediolateral axis (P = .035). Considering the complete interaction time, gender, and group, statistically significant differences were found (P = .015) for the anteroposterior rate covered by COP and the SD in the anteroposterior axis (P = .033). In eyes closed condition, the intersubject analysis showed statistically significant differences for the interaction between group and gender for the variable mediolateral SD (P = .043). Considering the interaction of time with group, statistically significant differences were found for full length covered by COP (P = .017). Changes in postural sway were observed after a single GPR session, mainly at 48 hours, with different behaviors between men and women. Copyright © 2017. Published by Elsevier Inc.

  14. Impact of a single educational session on oral hygiene practices among children of a primary school of Meerut, India

    Directory of Open Access Journals (Sweden)

    Pawan Parashar

    2013-10-01

    Full Text Available Oral health promotion through schools is recommended by the World Health Organization (WHO for improving knowledge, attitude, and behavior related to oral health and for prevention and control of dental diseases among school children. In low resource settings, it is important to develop evidence for health education methods in oral health behavioral practices. The objectives of this study were to assess both the baseline awareness and practices regarding oral hygiene and the impact of a single education session on the change in oral health behavior. A school based, cross-sectional study on 112 primary school children was conducted after obtaining the consent of the school authorities and parents. A pretested, structured proforma was used for baseline awareness and behavior regarding oral health. A 30 min educational session was imparted and after 1 month, and the oral health practices were reassessed to find out the impact of the education session. Baseline survey revealed the following findings. Self-reported dental problems were found in 48.22% of the children in the last 6 months. When asked about the risk factors for dental problems, 28.57% mentioned eating sweets followed by improper brushing, whereas 40.17% were not aware about any risk factor for dental problems. It was found that 28.57% of the children did not brush their teeth regularly, whereas 35.71% used a tooth-brush for brushing their teeth. After the intervention, it was observed that there was a significant improvement in the proportion of children using a toothbrush for cleaning their teeth and of those who rinsed their mouth after meals. In conclusion, even a single education session was found to be effective in bringing about a change in the oral health behavior of primary school children.

  15. A single-session growth mindset intervention for adolescent anxiety and depression: 9-month outcomes of a randomized trial.

    Science.gov (United States)

    Schleider, Jessica; Weisz, John

    2018-02-01

    Single-session interventions (SSIs) show promise in the prevention and treatment of youth psychopathology, carrying potential to improve the scalability and accessibility of youth psychological services. However, existing SSIs have conferred greater benefits for youths with anxiety, compared to depression or comorbid problems, and their effects have generally waned over time - particularly for follow-ups exceeding 3 months. To help address these discrepancies, we tested whether a novel SSI teaching growth mindset of personality (the belief that personality is malleable) could reduce depression and anxiety and strengthen perceived control in high-risk adolescents (N = 96, ages 12-15). At baseline, youths were randomized to receive a 30-min, computer-guided growth mindset intervention or a supportive-therapy control. Youths and parents reported youth anxiety and depressive symptoms, and youths reported their levels of perceived control, at baseline and across a 9-month follow-up period. Compared to the control program, the mindset intervention led to significantly greater improvements in parent-reported youth depression (d = .60) and anxiety (d = .28), youth-reported youth depression (d = .32), and youth-reported perceived behavioral control (d = .29) by 9-month follow-up. Intervention effects were nonsignificant for youth-reported anxiety, although 9-month effect sizes reached the small-to-medium range (d = .33). Intervention group youths also experienced more rapid improvements in parent-reported depression, youth-reported depression, and perceived behavioral control across the follow-up period, compared to control group youths. Findings suggest a promising, scalable SSI for reducing internalizing distress in high-risk adolescents. NCT03132298. © 2017 Association for Child and Adolescent Mental Health.

  16. The acute effects of a single session of expiratory muscle strength training on blood pressure, heart rate, and oxygen saturation in healthy adults.

    Science.gov (United States)

    Laciuga, Helena; Davenport, Paul; Sapienza, Christine

    2012-01-01

    Expiratory muscle strength training (EMST) is a rehabilitative program that has been tested for outcomes related to respiratory muscle strength, cough, swallow, and voice function in healthy young adult, elderly individuals, and in patients with progressive neurodegenerative disease. Because EMST has been used in patient care, the associated cardiovascular responses during EMST are of importance. This study investigated the changes in systolic blood pressure (SBP), diastolic blood pressure (DBP), heart rate (HR), and oxygen saturation (SpO(2)) during one session of EMST in healthy, young adults as a preliminary study of device safety. Thirty-one participants completed a single session of 25 trials with the EMST device. Valsalva maneuvers were performed at the beginning and at the end of the EMST trials for task comparison. The SBP, DBP, HR, and SpO(2) were recorded at the baseline and after completing the following tasks: a Valsalva maneuver, 12 trials using the EMST device, 13 trials using the EMST device, and 5 min of rest following the EMST session. A mixed linear model tested for changes across the six time points. The results indicated no significant change of SBP, DBP, HR, or SpO(2) during or following the EMST trials or after performing the Valsalva maneuver. The results suggest that EMST does not elicit significant fluctuations of blood pressure, HR, and SpO(2) in healthy young adults even when considering the effects of covariates on the outcomes measures.

  17. Immediate effects of a single session of robot-assisted gait training using Hybrid Assistive Limb (HAL) for cerebral palsy.

    Science.gov (United States)

    Matsuda, Mayumi; Mataki, Yuki; Mutsuzaki, Hirotaka; Yoshikawa, Kenichi; Takahashi, Kazushi; Enomoto, Keiko; Sano, Kumiko; Mizukami, Masafumi; Tomita, Kazuhide; Ohguro, Haruka; Iwasaki, Nobuaki

    2018-02-01

    [Purpose] Robot-assisted gait training (RAGT) using Hybrid Assistive Limb (HAL, CYBERDYNE) was previously reported beneficial for stroke and spinal cord injury patients. Here, we investigate the immediate effect of a single session of RAGT using HAL on gait function for cerebral palsy (CP) patients. [Subjects and Methods] Twelve patients (average age: 16.2 ± 7.3 years) with CP received a single session of RAGT using HAL. Gait speed, step length, cadence, single-leg support per gait cycle, hip and knee joint angle in stance, and swing phase per gait cycle were assessed before, during, and immediately after HAL intervention. [Results] Compared to baseline values, single-leg support per gait cycle (64.5 ± 15.8% to 69.3 ± 12.1%), hip extension angle in mid-stance (149.2 ± 19.0° to 155.5 ± 20.1°), and knee extension angle in mid-stance (137.6 ± 20.2° to 143.1 ± 19.5°) were significantly increased immediately after intervention. Further, the knee flexion angle in mid-swing was significantly decreased immediately after treatment (112.0 ± 15.5° to 105.2 ± 17.1°). Hip flexion angle in mid-swing also decreased following intervention (137.2 ± 14.6° to 129.7 ± 16.6°), but not significantly. Conversely, gait speed, step length, and cadence were unchanged after intervention. [Conclusion] A single-time RAGT with HAL improved single-leg support per gait cycle and hip and knee joint angle during gait, therapeutically improving gait function in CP patients.

  18. Anxiolytic Effects of a Single Session of the Exergame Zumba®Fitness on Healthy Young Women.

    Science.gov (United States)

    Viana, Ricardo Borges; Alves, Claudia Lima; Vieira, Carlos Alexandre; Vancini, Rodrigo Luiz; Campos, Mario Hebling; Gentil, Paulo; Andrade, Marília Santos; de Lira, Claudio Andre Barbosa

    2017-12-01

    Exergames appear to be a promising tool to increase energy expenditure and physical fitness. However, less is known about the effect of a single session of an exergame on anxiety state. Thus, the aim of this study was to evaluate the effects of a single session of the exergame Zumba ® Fitness (Xbox 360 Kinect ® ) on the anxiety state of healthy young women. Forty healthy young women (22.9 ± 3.7 years; 62.43 ± 8.75 kg; 1.64 ± 0.06 m; 23.05 ± 2.75 kg/m 2 ; [Formula: see text]O 2 max of 41.23 ± 10.61 mL/kg/min) performed ∼20 minutes of the exergame Zumba Fitness using the Xbox 360 Kinect. The state anxiety (State Anxiety Inventory) and level of enjoyment (Physical Activity Enjoyment Scale) were evaluated before and after intervention. Rating perceived exertion (Borg scale) and heart rate (HR) were also tracked and collected. A single exergame session significantly reduced the state anxiety of the participants (P = 0.0230, effect size = 0.62, CI 0.34-0.90). However, no statistically significant correlation was found between enjoyment and absolute (r = -0.10, P = 0.5345) or relative change in state anxiety (r = -0.17, P = 0.2869). A moderate positive correlation was found between enjoyment and performance in the exergame Zumba Fitness (r = 0.59, P = 0.0001). The mean HR during exergames was 137 ± 19 bpm (∼70% of predicted HRmax). The exergame Zumba Fitness seems to be a useful tool to reduce state anxiety in a nonclinical sample of healthy women.

  19. Single-Session CT-Guided Percutaneous Microwave Ablation of Bilateral Adrenal Gland Hyperplasia Due to Ectopic ACTH Syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Sarma, Asha, E-mail: ashasarma@gmail.com; Shyn, Paul B., E-mail: pshyn@partners.org [Brigham and Women’s Hospital, Department of Radiology (United States); Vivian, Mark A. [University of Manitoba, Department of Radiology (Canada); Ng, Ju-Mei [Brigham and Women’s Hospital, Department of Anesthesiology (United States); Tuncali, Kemal [Brigham and Women’s Hospital, Department of Radiology (United States); Lorch, Jorchen H. [Dana Farber Cancer Institute, Department of Medicine (United States); Zaheer, Sarah N.; Gordon, Michael S. [Brigham and Women’s Hospital, Department of Endocrinology (United States); Silverman, Stuart G. [Brigham and Women’s Hospital, Department of Radiology (United States)

    2015-10-15

    Bilateral adrenalectomy is currently the only available treatment for adrenocorticotropic hormone (ACTH)-dependent Cushing’s syndrome (ectopic ACTH syndrome) that is refractory to pharmacologic therapy. We describe two patients with refractory ectopic ACTH syndrome who were treated with CT-guided percutaneous microwave ablation of both hyperplastic adrenal glands in a single session: One was not a surgical candidate, and the other had undergone unsuccessful surgery. Following the procedure, both patients achieved substantial decreases in serum cortisol, symptomatic improvement, and decreased anti-hypertensive medication requirements.

  20. Sleep quality improved following a single session of moderate-intensity aerobic exercise in older women: Results from a pilot study

    Science.gov (United States)

    Wang, Xuewen; Youngstedt, Shawn D.

    2014-01-01

    Background Poor sleep quality is associated with adverse effects on health outcomes. It is not clear whether exercise can improve sleep quality and whether intensity of exercise affects any of the effects. Methods Fifteen healthy, non-obese (body mass index = 24.4 ± 2.1 kg/m2, mean ± SD), sedentary (exercise on no more than 3 times/week) older women (66.1 ± 3.9 years) volunteered for the study. Peak oxygen consumption (VO2peak) was evaluated using a graded exercise test on a treadmill with a metabolic cart. Following a 7-day baseline period, each participant completed two exercise sessions (separated by 1 week) with equal caloric expenditure, but at different intensities (60% and 45% VO2peak, sequence randomized) between 9:00 and 11:00 am. A wrist ActiGraph monitor was used to assess sleep at baseline and two nights following each exercise session. Results The average duration of the exercise was 54 and 72 min, respectively at 60% (moderate-intensity) and 45% VO2peak (light-intensity). Wake time after sleep onset was significantly shorter (p = 0.016), the number of awakenings was less (p = 0.046), and total activity counts were lower (p = 0.05) after the moderate-intensity exercise compared to baseline no-exercise condition. Conclusion Our data showed that a single moderate-intensity aerobic exercise session improved sleep quality in older women. PMID:25685605

  1. Sleep quality improved following a single session of moderate-intensity aerobic exercise in older women: Results from a pilot study.

    Science.gov (United States)

    Wang, Xuewen; Youngstedt, Shawn D

    2014-12-01

    Poor sleep quality is associated with adverse effects on health outcomes. It is not clear whether exercise can improve sleep quality and whether intensity of exercise affects any of the effects. Fifteen healthy, non-obese (body mass index = 24.4 ± 2.1 kg/m 2 , mean ± SD), sedentary (exercise on no more than 3 times/week) older women (66.1 ± 3.9 years) volunteered for the study. Peak oxygen consumption (VO 2peak ) was evaluated using a graded exercise test on a treadmill with a metabolic cart. Following a 7-day baseline period, each participant completed two exercise sessions (separated by 1 week) with equal caloric expenditure, but at different intensities (60% and 45% VO 2peak , sequence randomized) between 9:00 and 11:00 am. A wrist ActiGraph monitor was used to assess sleep at baseline and two nights following each exercise session. The average duration of the exercise was 54 and 72 min, respectively at 60% (moderate-intensity) and 45% VO 2peak (light-intensity). Wake time after sleep onset was significantly shorter ( p = 0.016), the number of awakenings was less ( p = 0.046), and total activity counts were lower ( p = 0.05) after the moderate-intensity exercise compared to baseline no-exercise condition. Our data showed that a single moderate-intensity aerobic exercise session improved sleep quality in older women.

  2. A Behavioral Analysis of Figurative Language in Psychotherapy: One Session in a Single Case Study.

    Science.gov (United States)

    Pollio, Howard R.; Barlow, Jack M.

    Assuming that all problem solving has both its rational and poetic aspects and that the solution to a problem is often found in the poetic well before it surfaces in the rational, this study examined in detail the ebb and flow of figurative language as it occurred in the course of a single, highly successful hour of gestalt therapy involving both…

  3. Single-session percutaneous ethanol sclerotherapy in simple renal cysts in children: long-term follow-up

    Energy Technology Data Exchange (ETDEWEB)

    Akinci, Devrim; Gumus, Burcak; Ozkan, Orhan S.; Ozmen, Mustafa N.; Akhan, Okan [Hacettepe University School of Medicine, Department of Radiology, Ankara (Turkey)

    2005-02-01

    Simple renal cysts are rare in children and managed conservatively unless symptomatic. To demonstrate the efficacy and long-term results of single-session ethanol sclerotherapy in symptomatic simple renal cysts in children. Three simple renal cysts in three children (age 1, 5 and 16 years) were included in the study. Indications for treatment were flank pain (n=1), hypertension (n=1), and increasing cyst size and urinary tract infection (n=1). The mean follow-up period was 5.5 years (range 3-7 years). The procedures were performed with the guidance of US and fluoroscopy and under IV sedation. After the cystogram, 95% ethanol with a volume of 40% of the cyst volume (but not more than 100 ml) was used as the sclerosing agent. Two cysts disappeared completely, while the volume reduction was 99% for the third cyst at the end of the first year. CT demonstrated calcification of the cyst without an enhancing soft-tissue component in the third one 7 years after sclerotherapy. After the procedures, hypertension and pain resolved without any medication. There were no complications during the procedures or during follow-up. Cytological examination was unremarkable in all patients. Percutaneous treatment of symptomatic simple renal cysts in children with single-session ethanol sclerotherapy is a safe, effective and minimally invasive procedure. Calcification owing to sclerotherapy can be observed on follow-up. (orig.)

  4. l-arginine modulates inflammation and muscle regulatory genes after a single session of resistance exercise in rats.

    Science.gov (United States)

    Morais, S R L; Brito, V G B; Mello, W G; Oliveira, S H P

    2018-02-01

    We investigated the skeletal muscle adaptation to l-arginine supplementation prior to a single session of resistance exercise (RE) during the early phase of muscle repair. Wistar rats were randomly assigned into non-exercised (Control), RE plus vehicle (RE); RE plus l-arginine (RE+L-arg) and RE plus aminoguanidine (RE+AG) groups. Animals received four doses of either vehicle (0.9% NaCl), l-arg (1 g/b.w.), or AG (iNOS inhibitor) (50 mg/b.w.). The animals performed a single RE session until the concentric failure (ladder climbing; 80% overload) and the skeletal muscles were harvested at 0, 8, 24, and 48 hours post-RE. The RE resulted in increased neutrophil infiltrate (24 hours post-RE) (3621 vs 11852; Pl-arginine supplementation attenuates neutrophil infiltration (5622; Pl-arginine supplementation seems to attenuate the resolution of RE-induced muscle inflammation and up-regulates MyoD expression during the early phase of muscle repair. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  5. A pilot study of a single-session training to promote mindful eating.

    Science.gov (United States)

    Jacobs, Jayme; Cardaciotto, LeeAnn; Block-Lerner, Jennifer; McMahon, Cori

    2013-01-01

    Although researchers have not yet examined the applicability of mindfulness for weight-gain prevention, mindfulness training has the potential to increase an individual's awareness of factors that enable an individual to avoid weight gain caused by overconsumption. The study intended to examine the effects of 1 h of mindfulness training on state mindfulness and food consumption. The research team performed a pilot study. The study occurred at an urban, northeastern, Catholic university. Participants were 26 undergraduate, English-speaking students who were at least 18 y old (77% female, 73% Caucasian). Students with food allergies, an inability to fast, or a current or past diagnosis of an eating disorder were ineligible. Participants fasted for 4 h. Between the third and fourth hours, they attended a 1-h session of mindfulness training that integrated three experiential mindfulness exercises with group discussion. Following training, they applied the skills they learned during a silent lunch. The Toronto Mindfulness Scale (TMS), the Awareness subscale of the Philadelphia Mindfulness Scale (PHLMS-AW), and a modified version of the Acting with Awareness subscale of the Five-Facet Mindfulness Questionnaire (FFMQ-AW) were used preand posttraining to assess changes in state mindfulness, present-moment awareness, and mealtime awareness, respectively. A postmeal, subjective hunger/fullness Likert scale was used to assess food consumption (healthy vs unhealthy consumption). The study found a statistically significant increase in state mindfulness (P=.002). Eighty-six percent of participants engaged in healthy food consumption. No statistically significant changes occurred in either present-moment awareness (P=.617) or mealtime awareness (P=.483). Preliminary results suggest promising benefits for use of mindfulness training on weight-gain prevention in healthy individuals. More research is needed to understand the impact that mindfulness may have on long-term, weight

  6. [Treating specific childhood phobia in a single session? A systematic review of the literature].

    Science.gov (United States)

    Fond, G; Franc, N

    2013-04-01

    phobias respond robustly to in vivo exposure, but this approach is associated with high dropout rates and low treatment acceptance. One Session Treatment, a variant of cognitive-behavioral therapy, combines graduated in vivo exposure, participant modeling, reinforcement, psychoeducation, cognitive challenges, and skills training in an intensive treatment model. The limited data available on medication shows little promise. Finally, relapse is a common phenomenon, and little is known on the long-term outcome of the illness. Copyright © 2012 L’Encéphale, Paris. Published by Elsevier Masson SAS. All rights reserved.

  7. Rapid Response of Long-Standing, Treatment-Resistant Non-Catatonic Mutism in Paranoid Schizophrenia with Single ECT session.

    Science.gov (United States)

    Dar, Mansoor Ahmad; Rather, Yasir Hassan; Shah, Majid Shafi; Wani, Rayees Ahmad; Hussain, Arshad

    2014-11-01

    Mutism is a common manifestation of catatonia, but mutism due to other forms of psychopathology and neurological disorders have also been described. Although not common, long-standing mutism has also been a feature of non-catatonic schizophrenia and traditionally responds less to conventional therapies. We describe a rare case of paranoid schizophrenia presenting with continuous mutism for about 4 years. This 26-year-old male had symptoms of schizophrenia without catatonia. After failed trial of adequate pharmacotherapy and psychological intervention and considering his level of dysfunction, he was started on electroconvulsive therapy (ECT). To our surprise, he improved with a single session of ECT while he was on concurrent pharmacotherapy. We also discuss the possible explanation for this rapid effect of ECT in such clinical presentation. To our knowledge, this is the first case of non-catatonic mutism of schizophrenia of this long duration responding so promptly to ECT, although there are other reports as well in literature, but multiple ECT sessions were applied in those cases. Non-catatonic mutism is perhaps presenting as a cultural variant in this part of the world and whenever encountered, ECT should be an option. Further research should be carried out to validate this idea.

  8. Single-session combination treatment with intense pulsed light and nonablative fractional photothermolysis: a split-face study.

    Science.gov (United States)

    Kearney, Chris; Brew, Daniel

    2012-07-01

    Intense pulsed light (IPL) and fractional photothermolysis (FP) are effective nonablative treatments for photoaging. To investigate the safety and efficacy of administering these two treatments in the same session with the aim of maximizing results while maintaining safety and minimizing downtime. We sought to compare the efficacy of the combination treatment with that of individual treatments of IPL and FP by conducting a split-face study. Twenty-nine subjects received a full-face standard-strength treatment with IPL immediately followed by treatment with 1550-nm FP. A further 14 patients underwent a split-face study comparing combined IPL and FP on one side of the face with these two treatments performed in isolation, 4 weeks apart, on the other side. The combination treatment achieved results statistically superior to treatment with IPL alone, FP alone, and treatment with IPL and FP performed 4 weeks apart. Downtime and adverse events were similar to those expected with individual treatments of IPL or FP alone. Intense pulsed light and PF appear to be synergistic when performed together in a single session, and the combination treatment is associated with a good safety profile and minimal downtime. © 2012 by the American Society for Dermatologic Surgery, Inc. Published by Wiley Periodicals, Inc.

  9. Effects of a Single Session of High Intensity Interval Treadmill Training on Corticomotor Excitability following Stroke: Implications for Therapy

    Directory of Open Access Journals (Sweden)

    Sangeetha Madhavan

    2016-01-01

    Full Text Available Objective. High intensity interval treadmill training (HIITT has been gaining popularity for gait rehabilitation after stroke. In this study, we examined the changes in excitability of the lower limb motor cortical representation (M1 in chronic stroke survivors following a single session of HIITT. We also determined whether exercise-induced changes in excitability could be modulated by transcranial direct current stimulation (tDCS enhanced with a paretic ankle skill acquisition task. Methods. Eleven individuals with chronic stroke participated in two 40-minute treadmill-training sessions: HIITT alone and HITT preceded by anodal tDCS enhanced with a skill acquisition task (e-tDCS+HIITT. Transcranial magnetic stimulation (TMS was used to assess corticomotor excitability of paretic and nonparetic tibialis anterior (TA muscles. Results. HIIT alone reduced paretic TA M1 excitability in 7 of 11 participants by ≥ 10%. e-tDCS+HIITT increased paretic TA M1 excitability and decreased nonparetic TA M1 excitability. Conclusions. HIITT suppresses corticomotor excitability in some people with chronic stroke. When HIITT is preceded by tDCS in combination with a skill acquisition task, the asymmetry of between-hemisphere corticomotor excitability is reduced. Significance. This study provides preliminary data indicating that the cardiovascular benefits of HIITT may be achieved without suppressing motor excitability in some stroke survivors.

  10. [Initial clinical experiences with the Storz Modulith SL 20 lithotripter: the results 3 months after a single session].

    Science.gov (United States)

    Roques, N; Anidjar, M; Soussi, N; Gemayel, T; Hermieux, J F; Ravery, V; Nimier, M; Delmas, V; Boccon-Gibod, L

    1995-02-01

    The objective of this study was to evaluate the performances of the Storz Modulith SL20 lithotriptor. Fifty patients with a total of 52 renal (31) or ureteric (21) stones were treated, in a single session, between June and October 1993. The mean stone diameter was 7.9 mm. All patients were reviewed after 3 months. The complete success rate, with radiological cure, was 65% at 3 months. The partial success rate, defined as fragmentation of the stone with persistence of residual fragments less than 3 mm in diameter, not requiring further treatment, was 12% at 3 months. The failure rate at 3 months was 23%. The commonest complication was renal colic in 12 patients (24%). Two patients developed an extrarenal haematoma. The Modulith SL20 possesses a good detection system: firing is well tolerated under minimal analgesia. Our success rates are slightly lower than those obtained by other teams using the same apparatus.

  11. Paralysis following stereotactic spinal irradiation in pigs suggests a tolerance constraint for single-session irradiation of the spinal nerve

    International Nuclear Information System (INIS)

    Medin, Paul M.; Foster, Ryan D.; Kogel, Albert J. van der; Meyer, Jeffrey; Sayre, James W.; Huang, Hao; Öz, Orhan K.

    2013-01-01

    Background and purpose: Paralysis observed during a study of vertebral bone tolerance to single-session irradiation led to further study of the dose-related incidence of motor peripheral neuropathy. Materials and methods: During a bone tolerance study, cervical spinal nerves of 15 minipigs received bilateral irradiation to levels C5–C8 distributed into three dose groups with mean maximum spinal nerve doses of 16.9 ± 0.3 Gy (n = 5), 18.7 ± 0.5 Gy (n = 5), and 24.3 ± 0.8 Gy (n = 5). Changes developing in the gait of the group of pigs receiving a mean maximum dose of 24.3 Gy after 10–15 weeks led to the irradiation of two additional animals. They received mean maximum dose of 24.9 ± 0.2 Gy (n = 2), targeted to the left spinal nerves of C5–C8. The followup period was one year. Histologic sections from spinal cords and available spinal nerves were evaluated. MR imaging was performed on pigs in the 24.9 Gy group. Results: No pig that received a maximum spinal nerve point dose ⩽19.0 Gy experienced a change in gait while all pigs that received ⩾24.1 Gy experienced paralysis. Extensive degeneration and fibrosis were observed in irradiated spinal nerves of the 24.9 Gy animals. All spinal cord sections were normal. Irradiated spinal nerve regions showed increased thickness and hypointensity on MR imaging. Conclusion: The single-session tolerance dose of the cervical spinal nerves lies between 19.0 and 24.1 Gy for this model

  12. Neural Response After a Single ECT Session During Retrieval of Emotional Self-Referent Words in Depression: A Randomized, Sham-Controlled fMRI Study

    Science.gov (United States)

    Miskowiak, Kamilla W; Macoveanu, Julian; Jørgensen, Martin B; Støttrup, Mette M; Ott, Caroline V; Jensen, Hans M; Jørgensen, Anders; Harmer, J; Paulson, Olaf B; Kessing, Lars V; Siebner, Hartwig R

    2018-01-01

    Abstract Background Negative neurocognitive bias is a core feature of depression that is reversed by antidepressant drug treatment. However, it is unclear whether modulation of neurocognitive bias is a common mechanism of distinct biological treatments. This randomized controlled functional magnetic resonance imaging study explored the effects of a single electroconvulsive therapy session on self-referent emotional processing. Methods Twenty-nine patients with treatment-resistant major depressive disorder were randomized to one active or sham electroconvulsive therapy session at the beginning of their electroconvulsive therapy course in a double-blind, between-groups design. The following day, patients were given a self-referential emotional word categorization test and a free recall test. This was followed by an incidental word recognition task during whole-brain functional magnetic resonance imaging at 3T. Mood was assessed at baseline, on the functional magnetic resonance imaging day, and after 6 electroconvulsive therapy sessions. Data were complete and analyzed for 25 patients (electroconvulsive therapy: n = 14, sham: n = 11). The functional magnetic resonance imaging data were analyzed using the FMRIB Software Library randomize algorithm, and the Threshold-Free Cluster Enhancement method was used to identify significant clusters (corrected at P words. However, electroconvulsive therapy reduced the retrieval-specific neural response for positive words in the left frontopolar cortex. This effect occurred in the absence of differences between groups in behavioral performance or mood symptoms. Conclusions The observed effect of electroconvulsive therapy on prefrontal response may reflect early facilitation of memory for positive self-referent information, which could contribute to improvements in depressive symptoms including feelings of self-worth with repeated treatments. PMID:29718333

  13. Single Event Effect (SEE) Test Planning 101

    Science.gov (United States)

    LaBel, Kenneth A.; Pellish, Jonathan; Berg, Melanie D.

    2011-01-01

    This is a course on SEE Test Plan development. It is an introductory discussion of the items that go into planning an SEE test that should complement the SEE test methodology used. Material will only cover heavy ion SEE testing and not proton, LASER, or other though many of the discussed items may be applicable. While standards and guidelines for how-to perform single event effects (SEE) testing have existed almost since the first cyclotron testing, guidance on the development of SEE test plans has not been as easy to find. In this section of the short course, we attempt to rectify this lack. We consider the approach outlined here as a "living" document: mission specific constraints and new technology related issues always need to be taken into account. We note that we will use the term "test planning" in the context of those items being included in a test plan.

  14. Reduction of bradykinesia of finger movements by a single session of action observation in Parkinson disease.

    Science.gov (United States)

    Pelosin, Elisa; Bove, Marco; Ruggeri, Piero; Avanzino, Laura; Abbruzzese, Giovanni

    2013-01-01

    Action observation influences motor performance in healthy subjects and persons with motor impairments. To understand the effects of action observation on the spontaneous rate of finger movements in patients with Parkinson disease (PD). Participants, 20 with PD and 14 healthy controls, were randomly divided into 2 groups. Those in the VIDEO group watched video clips showing repetitive finger movements paced at 3 Hz, whereas those in the ACOUSTIC group listened to an acoustic cue paced at 3 Hz. All participants performed a finger sequence at their spontaneous pace at different intervals (before, at the end of, 45 minutes after, and 2 days after training); 8 participants with PD were recruited for a sham intervention, watching a 6-minute video representing a static hand. Finally, 10 patients participated in the same protocol used for the VIDEO group but were tested in the on and off medication states. Both VIDEO and ACOUSTIC training increased the spontaneous rate in all participants. VIDEO intervention showed a greater effect over time, improving the spontaneous rate and reducing the intertapping interval to a larger extent than ACOUSTIC 45 minutes and 2 days after training. Action observation significantly influenced movement rate in on and off conditions, but 45 minutes after training, the effect was still present only in the on condition. No effect was observed after sham intervention. These findings suggest that the dopaminergic state contributes to the effects of action observation, and this training may be a promising approach in the rehabilitation of bradykinesia in PD.

  15. Acute Effects of Different Stretching Techniques on the Number of Repetitions in A Single Lower Body Resistance Training Session

    Directory of Open Access Journals (Sweden)

    Sá Marcos A.

    2015-03-01

    Full Text Available This study aimed to investigate the acute effects of passive static and ballistic stretching on maximal repetition performance during a resistance training session (RTS. Nine male subjects underwent three experimental conditions: ballistic stretching (BS; passive static stretching (PSS; and a specific warm-up (SW. The RTS was composed of three sets of 12RM for the following exercises: leg press 45 (LP, leg extension (LE, leg curl (LC, and plantar flexors (PF. Performance of six sessions was assessed 48 hours apart. The first visit consisted of a familiarization session including stretching methods and exercises used in the RTS. On the second and third visit, a strength test and retest were performed. During the fourth to the sixth visit, the volunteers randomly performed the following protocols: BS+RTS; PSS+RTS; or SW+RTS. For the sum of the RM number of each three-set exercise, significant differences were found between PSS vs. SW for the LP (p = 0.001; LE (p = 0.005; MF (p = 0.001; and PF (p = 0.038. For the comparison between the methods of stretching PSS vs. BS, significant differences were found only for the FP (p = 0.019. When analyzing the method of stretching BS vs. SW, significant differences were found for the LP (p = 0.014 and MF (p = 0.002. For the total sum of the RM number of three sets of the four exercises that composed the RTS, significant differences were observed (p < 0.05 in the following comparisons: PPS vs. SW (p = 0.001, PPS vs. BS (p = 0.008, and BS vs. SW (p = 0.002. Accordingly, the methods of passive static and ballistic stretching should not be recommended before a RTS.

  16. Rapid improvement of depressive symptoms and cognition in an elderly patient with a single session of piano playing: a clinical treatment report.

    Science.gov (United States)

    Manalai, Gul; Manalai, Partam; Dutta, Raja; Fegan, Gerald; Scrofani, Philip

    2012-06-01

    Music has been used as a non-pharmacological modality in the treatment of different conditions since ancient times. It has received attention in modern medicine in recent decades, particularly in geriatric population. The effects of music on mood and cognition are well documented. The aim of the current case report is to highlight the benefits of musical activities in the geriatric population. We report a naturalistic treatment outcome in an elderly patient on a geriatric psychiatric unit related to a single session of piano playing. A rapid and sustained improvement in mood and cognition of an elderly patient was observed after a single session of playing piano. Notwithstanding the limitations of a single subject, uncontrolled case study, the effect was dramatic. Our findings support previous claims regarding music therapy including effects of a single session music-based therapeutic interventions, and we conclude that music therapy for geriatric patients with mood and cognitive deficits is worth further systematic investigation.

  17. Physiological effects of a single chest physiotherapy session in mechanically ventilated and extubated preterm neonates.

    Science.gov (United States)

    Mehta, Y; Shetye, J; Nanavati, R; Mehta, A

    2016-01-01

    To assess the changes on various physiological cardio-respiratory parameters with a single chest physiotherapy session in mechanically ventilated and extubated preterm neonates with respiratory distress syndrome. This is a prospective observational study in a neonatal intensive care unit setting. Sixty preterm neonates with respiratory distress syndrome, thirty mechanically ventilated and thirty extubated preterm neonates requiring chest physiotherapy were enrolled in the study. Parameters like heart rate (HR), respiratory rate (RR), Silverman Anderson score (SA score in extubated), oxygen saturation (SpO2) and auscultation findings were noted just before, immediately after chest physiotherapy but before suctioning, immediately after suctioning and after 5 minutes of the session. The mean age of neonates was 9.55±5.86 days and mean birth weight was 1550±511.5 g. As there was no significant difference in the change in parameters on intergroup comparison, further analysis was done considering two groups together (n = 60) except for SA score. As SA score was measured only in extubated neonates. HR did not change significantly during chest physiotherapy compared to the baseline but significantly decreased after 15 minutes (p = 0.01). RR and SA score significantly increased after suctioning (p = 0.014) but reduced after 15 minutes (p = physiotherapy (p = physiotherapy may help facilitate the overall well-being of a fragile preterm neonate. Lung auscultation finding suggests that after suctioning, there was a significant reduction in crepitation (p = 0.0000) but significant increase in crepitation after 15 minutes (p = physiotherapy. Chest physiotherapy is safe in preterm neonates. Suctioning causes significant cardio-respiratory parameter changes, but within normal physiological range. Thus, chest physiotherapy should be performed with continuous monitoring only when indicated and not as a routine procedure. More research is needed

  18. A single blind, clinical trial to investigate the effects of a single session extracorporeal shock wave therapy on wrist flexor spasticity after stroke.

    Science.gov (United States)

    Daliri, Seyedeh Somayeh; Forogh, Bijan; Emami Razavi, Seyedeh Zahra; Ahadi, Tannaz; Madjlesi, Faezeh; Ansari, Noureddin Nakhostin

    2015-01-01

    Spasticity is a common, serious symptom after stroke. Extracorporeal shock wave therapy (ESWT) has been suggested for the treatment of muscle spasticity. To investigate the effects of ESWT on post stroke wrist flexor spasticity. Fifteen patients with poststroke wrist flexor spasticity (12 male and 3 female with a mean age of 54 years) were enrolled. Patients received 1 sham ESWT followed by 1 active ESWT 1 week later. The outcome measures were the Modified Modified Ashworth Scale (MMAS), the Hmax/Mmax ratio, and the Brunnstrom motor recovery stage. The sham ESWT had not effects on the outcome measures. After active ESW, the MMAS scores of spasticity and the Hmax/Mmax ratio improved. The improvements were maintained 5 weeks after active ESWT. No significant improvements were observed for the motor recovery after sham or active ESWT. In adult patients after stroke, a single session of active ESWT resulted in significant improvement in the wrist flexor spasticity and alpha motor neuron excitability.

  19. Closing the feedback loop: engaging students in large first-year mathematics test revision sessions using pen-enabled screens

    Science.gov (United States)

    Donovan, Diane; Loch, Birgit

    2013-01-01

    How can active learning, peer learning and prompt feedback be achieved in large first-year mathematics classes? Further, what technologies may support these aims? In this article, we assert that test revision sessions in first-year mathematics held in a technology-enhanced lecture theatre can be highly interactive with students solving problems, learning from each other and receiving immediate feedback. This is facilitated by pen-enabled screens and synchronization software. We argue that the educational benefits achievable through the technology do outweigh the technological distractions, and that these benefits can be achieved by focused, targeted one-off sessions and not only by a semester-long, regular approach. Repeat mid-semester test revision sessions were offered on a non-compulsory basis using pen-enabled screens for all students. Students worked practice test questions and marked solutions to mathematical problems on the screens. Students' work was then displayed anonymously for their peers to see. Answers were discussed with the whole class. We discuss outcomes from two offerings of these sessions using student feedback and lecturer reflections and show the impact of participation on self-reported student confidence. Pedagogical approaches that the technology allowed for the first time in a large class are highlighted. Students responded uniformly positively.

  20. One-session treatment for specific phobias: a review of Öst's single-session exposure with children and adolescents.

    Science.gov (United States)

    Ollendick, Thomas H; Davis, Thompson E

    2013-01-01

    The purpose of this brief paper is to review the current status of one-session treatment (OST) for specific phobias in children and adolescents. Following a brief historical overview and description of OST, we systematically describe eight studies that have examined its efficacy in children and adolescents aged between 7 and17 years. We also explore phobia subtypes, age, gender, and comorbidity as possible moderators of treatment outcome. Studies have been conducted in Australia, Austria, the Netherlands, the USA, and Sweden. Although there is limited evidence that OST works better for animal phobias than other subtypes of phobias and for girls than boys, across studies there is considerable evidence that it is generally effective across phobia subtypes and for both boys and girls. No age differences in outcomes were noted, nor were any differences noted due to comorbidity. OST was found to be equally effective with children and adolescents with co-occurring multiple phobias and other anxiety disorders. Moreover, in at least one study, it was found to reduce untreated phobic and anxiety disorders in addition to the treated phobias. It is concluded that OST is a highly effective intervention for the treatment of specific phobias in children and adolescents.

  1. Does a single session of electroconvulsive therapy alter the neural response to emotional faces in depression? A randomised sham-controlled functional magnetic resonance imaging study

    DEFF Research Database (Denmark)

    Miskowiak, Kamilla W; Kessing, Lars V; Ott, Caroline V

    2017-01-01

    expression recognition and dot-probe tasks. A single electroconvulsive therapy session had no effect on amygdala response to emotional faces. Whole-brain analysis revealed no effects of electroconvulsive therapy versus sham therapy after family-wise error correction at the cluster level, using a cluster...... neurocognitive bias in major depressive disorder. Patients with major depressive disorder were randomised to one active ( n=15) or sham electroconvulsive therapy ( n=12). The following day they underwent whole-brain functional magnetic resonance imaging at 3T while viewing emotional faces and performed facial...... to faces after a single electroconvulsive therapy session, the observed trend changes after a single electroconvulsive therapy session point to an early shift in emotional processing that may contribute to antidepressant effects of electroconvulsive therapy....

  2. Coaching Tutors: An Instrumental Case Study on Testing an Integrated Framework for Tutoring Sessions

    Science.gov (United States)

    Holland, Alicia L.; Grant, Chris; Donthamsetty, Reshema

    2017-01-01

    The objective for the current qualitative case study was to examine participants' perceptions on the tutor coaching and session review frameworks. The location of the study was at the tutor coaches' place of business. At the beginning of the study, tutor coaches were trained on how to implement the tutoring coaching framework with their tutors,…

  3. Laboratory tests for single-event effects

    International Nuclear Information System (INIS)

    Buchner, S.; McMorrow, D.; Melinger, J.; Campbell, A.B.

    1996-01-01

    Integrated circuits are currently tested at accelerators for their susceptibility to single-event effects (SEE's). However, because of the cost and limited accessibility associated with accelerator testing, there is considerable interest in developing alternate testing methods. Two laboratory techniques for measuring SEE, one involving a pulsed laser and the other 252 Cf, are described in detail in this paper. The pulsed laser provides information on the spatial and temporal dependence of SEE, information that has proven invaluable in understanding and mitigating SEE in spite of the differences in the physical mechanisms responsible for SEE induced by light and by ions. Considerable effort has been expended on developing 252 Cf as a laboratory test for SEE, but the technique has not found wide use because it is severely limited by the low energy and short range of the emitted ions that are unable to reach junctions either covered with dielectric layers or deep below the surface. In fact, there are documented cases where single-event latchup (SEL) testing with 252 Cf gave significantly different results from accelerator testing. A detailed comparison of laboratory and accelerator SEE data is presented in this review in order to establish the limits of each technique

  4. Single-Session Hematoma Removal and Transcranial Coil Embolization for a Cavernous Sinus Dural Arteriovenous Fistula: A Technical Case Report.

    Science.gov (United States)

    Akamatsu, Yosuke; Sato, Kenichi; Endo, Hidenori; Matsumoto, Yasushi; Tominaga, Teiji

    2017-08-01

    Patients with cavernous sinus dural arteriovenous fistulas (CS dAVFs) with cortical venous varix are indicated for aggressive treatment because of the associated risk for intracranial hemorrhage. We present a case of surgical transvenous embolization in an 84-year-old woman with CS dAVF who presented with massive intracerebral hematoma. Cerebral angiograms revealed the dural AVF drained only into the superficial middle cerebral vein. Because an emergent mass reduction and prevention of rebleeding were necessary, single-session hematoma removal and transcranial embolization of a CS dAVF were performed in the neurosurgical operating room, using a mobile C-arm fluoroscopy. After the right frontotemporal craniotomy, intracerebral hematoma was removed and coil packing of the affected cavernous sinus was successfully performed via the dilated superficial middle cerebral vein. The transcortical vein approach enables occlusion of CS dAVF with isolated cortical venous drainage and may be a valuable alternative approach for some cases needed emergency craniotomy. Copyright © 2017 Elsevier Inc. All rights reserved.

  5. Single-session emotion regulation skills training to reduce aggression in combat veterans: A clinical innovation case study.

    Science.gov (United States)

    Miles, Shannon R; Thompson, Karin E; Stanley, Melinda A; Kent, Thomas A

    2016-05-01

    Posttraumatic stress disorder (PTSD) is common among returning veterans, and aggression frequently co-occurs with PTSD. Veterans with PTSD most commonly engage in impulsive aggression, or aggression that is emotionally charged, unplanned, and uncontrolled, rather than premeditated aggression, which is planned and controlled. Previous research demonstrated a variety of emotions can result in aggression, rather than the traditional conceptualization that only anger leads to aggression. In a veteran sample, deficiencies in the ability to regulate emotions (emotion dysregulation) mediated the relationship between PTSD and impulsive aggression. These results suggest that teaching veterans with PTSD and impulsive aggression how to regulate emotions may decrease aggression. The cases presented illustrate the use of an innovative, single-session emotion regulation treatment for combat veterans with PTSD. Two cases are presented to generate hypotheses on who might benefit from this treatment in the future. The two male veterans treated with this protocol differed in how frequently they used the emotion regulation skills after the treatment and in their treatment outcomes. Teaching veterans how to regulate their emotions in a condensed time frame may be beneficial for certain veterans, and further research on this brief treatment is warranted. (PsycINFO Database Record (c) 2016 APA, all rights reserved).

  6. NEXT Single String Integration Test Results

    Science.gov (United States)

    Soulas, George C.; Patterson, Michael J.; Pinero, Luis; Herman, Daniel A.; Snyder, Steven John

    2010-01-01

    As a critical part of NASA's Evolutionary Xenon Thruster (NEXT) test validation process, a single string integration test was performed on the NEXT ion propulsion system. The objectives of this test were to verify that an integrated system of major NEXT ion propulsion system elements meets project requirements, to demonstrate that the integrated system is functional across the entire power processor and xenon propellant management system input ranges, and to demonstrate to potential users that the NEXT propulsion system is ready for transition to flight. Propulsion system elements included in this system integration test were an engineering model ion thruster, an engineering model propellant management system, an engineering model power processor unit, and a digital control interface unit simulator that acted as a test console. Project requirements that were verified during this system integration test included individual element requirements ; integrated system requirements, and fault handling. This paper will present the results of these tests, which include: integrated ion propulsion system demonstrations of performance, functionality and fault handling; a thruster re-performance acceptance test to establish baseline performance: a risk-reduction PMS-thruster integration test: and propellant management system calibration checks.

  7. Pilot Evaluation of the Feasibility and Acceptability of StressOFF Strategies: A Single-Session School-Based Stress Management Program for Adolescents

    Science.gov (United States)

    Shapiro, Amy J.; Heath, Nancy L.; Carsley, Dana

    2016-01-01

    The present study reports the pilot evaluation of the feasibility and acceptability of StressOFF Strategies, a "single-session" (45 min) adolescent-targeted, school-based psychoeducational program, which introduces cognitive behavioral techniques and mindfulness-based techniques. Five hundred and sixty-five Grade 9 students (57% female;…

  8. Using Elite Athletes to Promote Drug Abstinence: Evaluation of a Single-Session School-Based Drug Use Prevention Program Delivered by Junior Hockey Players

    Science.gov (United States)

    Wong, Jennifer

    2016-01-01

    School-based substance use prevention programs are a common method to approaching drug use in youths. Project SOS is a single-session drug prevention program developed by police officers and delivered by elite junior hockey players to students in grades 6 and 7. The current study evaluates the effects of Project SOS at achieving its objectives of…

  9. It IS worth the effort: Patient knowledge of reproductive aspects of inflammatory bowel disease improves dramatically after a single group education session.

    Science.gov (United States)

    Mountifield, Réme; Andrews, Jane M; Bampton, Peter

    2014-08-01

    Individuals with Inflammatory Bowel Disease (IBD) have poor knowledge regarding the implications of disease for fertility and pregnancy. Previous studies suggest that this poor knowledge adversely influences reproductive decision making. To examine the effect of a single group education session on IBD-specific reproductive knowledge in subjects with IBD. People with IBD attending an educational event were invited to complete the CCPKnow questionnaire, testing reproductive knowledge in IBD, before and after an evidenced based presentation on this topic delivered by a Gastroenterologist. Of 248 attendees, 155 participated; 69% female, mean age 40.3years. CCPKnow scores (maximum 17) were low at baseline and increased significantly post education (mean 5.4 pre vs. 14.5 post education; p<0.0001). A large majority (65.1%) of subjects had "poor" (score <8) knowledge at baseline, compared with only 1.9% after education (p<0.0001). Whilst all subareas of knowledge improved after education, the most important improvement was in attitudes toward medication use in pregnancy: 33.5% of subjects indicated at baseline that women should avoid all drugs in pregnancy compared with only 1.2% post education (p<0.0001). A single group-delivered education event focussed on reproductive issues in IBD can dramatically improve patient knowledge. This has the potential to change reproductive behaviour and may reduce voluntary childlessness resulting from misperceptions amongst individuals with IBD. Crown Copyright © 2013. Published by Elsevier B.V. All rights reserved.

  10. Single session imaging of cerebellum at 7 Tesla: obtaining structure and function of multiple motor subsystems in individual subjects.

    Directory of Open Access Journals (Sweden)

    Melissa A Batson

    Full Text Available The recent increase in the use of high field MR systems is accompanied by a demand for acquisition techniques and coil systems that can take advantage of increased power and accuracy without being susceptible to increased noise. Physical location and anatomical complexity of targeted regions must be considered when attempting to image deeper structures with small nuclei and/or complex cytoarchitechtonics (i.e. small microvasculature and deep nuclei, such as the brainstem and the cerebellum (Cb. Once these obstacles are overcome, the concomitant increase in signal strength at higher field strength should allow for faster acquisition of MR images. Here we show that it is technically feasible to quickly and accurately detect blood oxygen level dependent (BOLD signal changes and obtain anatomical images of Cb at high spatial resolutions in individual subjects at 7 Tesla in a single one-hour session. Images were obtained using two high-density multi-element surface coils (32 channels in total placed beneath the head at the level of Cb, two channel transmission, and three-dimensional sensitivity encoded (3D, SENSE acquisitions to investigate sensorimotor activations in Cb. Two classic sensorimotor tasks were used to detect Cb activations. BOLD signal changes during motor activity resulted in concentrated clusters of activity within the Cb lobules associated with each task, observed consistently and independently in each subject: Oculomotor vermis (VI/VII and CrusI/II for pro- and anti-saccades; ipsilateral hemispheres IV-VI for finger tapping; and topographical separation of eye- and hand- activations in hemispheres VI and VIIb/VIII. Though fast temporal resolution was not attempted here, these functional patches of highly specific BOLD signal changes may reflect small-scale shunting of blood in the microvasculature of Cb. The observed improvements in acquisition time and signal detection are ideal for individualized investigations such as

  11. Impact of a single session of intermittent pneumatic leg compressions on skeletal muscle and isolated artery gene expression in rats.

    Science.gov (United States)

    Roseguini, Bruno T; Arce-Esquivel, Arturo A; Newcomer, Sean C; Laughlin, M H

    2011-12-01

    Intermittent pneumatic leg compressions (IPC) have proven to be an effective noninvasive approach for treatment of patients with claudication, but the mechanisms underlying the clinical benefits remain elusive. In the present study, a rodent model of claudication produced by bilateral ligation of the femoral artery was used to investigate the acute impact of a single session of IPC (150 min) on hemodynamics, skeletal muscle (tibialis anterior), and isolated collateral artery (perforating artery) expression of a subset of genes associated with inflammation and vascular remodeling. In addition, the effect of compression frequency (15 vs. 3 compressions/min) on the expression of these factors was studied. In ligated animals, IPC evoked an increase of monocyte chemoattractant protein-1 (MCP-1) and cytokine-induced neutrophil chemoattractant 1 (CXCL1) mRNA (P < 0.01) and immunostaining (P < 0.05), as well as a minor increase in VEGF immunostaining in the muscle endomysium 150 min postintervention. Further, collateral arteries from these animals showed an increased expression of MCP-1 (approximately twofold, P = 0.02). These effects were most evident in the group exposed to the high-frequency protocol (15 compressions/min). In contrast, IPC in sham-operated control animals evoked a modest initial upregulation of VEGF (P = 0.01), MCP-1 (P = 0.02), and CXCL1 (P = 0.03) mRNA in the muscle without concomitant changes in protein levels. No changes in gene expression were observed in arteries isolated from sham animals. In conclusion, IPC acutely up-regulates the expression of important factors involved in vascular remodeling in the compressed muscle and collateral arteries in a model of hindlimb ischemia. These effects appear to be dependent on the compression frequency, such that a high compression frequency (15 compressions/min) evokes more consistent and robust effects compared with the frequency commonly employed clinically to treat patients with claudication (3

  12. The "g" Factor and Cognitive Test Session Behavior: Using a Latent Variable Approach in Examining Measurement Invariance Across Age Groups on the WJ III

    Science.gov (United States)

    Frisby, Craig L.; Wang, Ze

    2016-01-01

    Data from the standardization sample of the Woodcock-Johnson Psychoeducational Battery--Third Edition (WJ III) Cognitive standard battery and Test Session Observation Checklist items were analyzed to understand the relationship between g (general mental ability) and test session behavior (TSB; n = 5,769). Latent variable modeling methods were used…

  13. Comparison of the effect of multiple short-duration with single long-duration exercise sessions on glucose homeostasis in type 2 diabetes mellitus

    DEFF Research Database (Denmark)

    Eriksen, L; Dahl-Petersen, I; Haugaard, Steen B

    2007-01-01

    AIMS/HYPOTHESIS: We evaluated and compared the effects on glycaemic control of two different exercise protocols in elderly men with type 2 diabetes mellitus. METHODS: Eighteen patients with type 2 diabetes mellitus carried out home-based bicycle training for 5 weeks. Patients were randomly assigned...... glucose OGTT (p = 0.04) and plasma glucose concentration areas under the curve at 120 min (p exercise groups...... increased similarly in both exercise groups. A possible explanation is that the energy expenditure associated with multiple short daily sessions may be greater than that in a single daily session. Udgivelsesdato: 2007-Nov...

  14. Improving Single Event Effects Testing Through Software

    Science.gov (United States)

    Banker, M. W.

    2011-01-01

    Radiation encountered in space environments can be damaging to microelectronics and potentially cause spacecraft failure. Single event effects (SEE) are a type of radiation effect that occur when an ion strikes a device. Single event gate rupture (SEGR) is a type of SEE that can cause failure in power transistors. Unlike other SEE rates in which a constant linear energy transfer (LET) can be used, SEGR rates sometimes require a non-uniform LET to be used to be accurate. A recent analysis shows that SEGR rates are most easily calculated when the environment is described as a stopping rate per unit volume for each ion species. Stopping rates in silicon for pertinent ions were calculated using the Stopping and Range of Ions in Matter (SRIM) software and CREME-MC software. A reference table was generated and can be used by others to calculate SEGR rates for a candidate device. Additionally, lasers can be used to simulate SEEs, providing more control and information at lower cost than heavy ion testing. The electron/hole pair generation rate from a laser pulse in a semiconductor can be related to the LET of an ion. MATLAB was used to generate a plot to easily make this comparison.

  15. Safety of ferric carboxymaltose immediately after infliximab administration, in a single session, in inflammatory bowel disease patients with iron deficiency: a pilot study.

    Directory of Open Access Journals (Sweden)

    Xavier Cortes

    Full Text Available To obtain preliminary safety and efficacy data on intravenous (IV administration of infliximab (IFX and ferric carboxymaltose (FCM to inflammatory bowel disease (IBD patients in a single treatment session.A two-phase non-interventional, observational, prospective pilot study was performed to evaluate safety and efficacy of FCM given immediately after IFX. IBD patients were recruited consecutively in the outpatient clinic in two groups. Control group patients (n = 12 received FCM on a separate day from IFX. Subsequently, single-session group patients (n = 33 received FCM after IFX on the same day. All patients received 5mg/kg IFX and 1000mg FCM for iron-restricted anemia (IRA or 500mg FCM for iron deficiency without anemia. Safety assessment was performed by recording adverse events (AEs during and immediately after infusion, 30 minutes afterwards, and via follow-up at 7 days and 8 weeks. For efficacy assessment, hematological parameters were assessed prior to FCM infusion (pre-FCM and after 8 weeks. Economic impact of FCM given immediately after IFX was assessed.All 45 patients (35 Crohn´s disease, 10 ulcerative colitis received IFX 5mg/kg. 21 patients received 500mg FCM and 24 received 1000mg. FCM administration immediately after IFX corrected iron deficiency or IRA as shown by increases in hematological parameters. No AEs were reported during the safety evaluation at the end of FCM or IFX administration, 30 minutes, 7 days and 8 weeks afterwards, in either control or single-session groups. Total cost per patient for single-session administration was 354.63€; for patients receiving IFX and FCM on separate days, it was 531.94€, giving a 177.31€ per-patient cost saving.Single-session administration of FCM after IFX was safe and effective in IBD patients and can offer a good cost-benefit ratio and improve treatment adherence. To our knowledge, this study is the first to evaluate FCM and IFX administration in a single treatment session.

  16. Proceedings of the International Test and Evaluation Association 1984 Symposium (Step Session). Supplement.

    Science.gov (United States)

    1985-04-01

    computer software for nission-critical applications. * The Software Test and Evaluation Guidebook is a two volume reference set that provides checklists ...Deputy Test Director for Software Evaluation ( DSE ) is a key AFOTEC position on the field test team. The DSE is supported by software evaluators from the

  17. Testing Procedure for the Single Fiber Fragmentation Test

    DEFF Research Database (Denmark)

    Feih, Stefanie; Wonsyld, Karen; Minzari, Daniel

    , specimens with one E-glass fiber placed inside an epoxy or polyester matrix were used. Elongating the specimens with a mini tensile tester, which was placed under a microscope, leads to fiber fragmentations. Different bonding strengths between fiber and matrix result in differences in the critical fracture......This report describes the details of the single fiber fragmentation test as conducted at the materials research department (AFM) at Risø. The equipment and specimen manufacture is described in detail. Furthermore, examples of results interpretation are given. For the experiments in this report...... length for the fiber and fracture characteristics....

  18. WE-AB-207B-10: On Spinal Nerve Toxicity from Single-Session SAbR in Pigs and the Translation of Small Animal NTCP Models

    Energy Technology Data Exchange (ETDEWEB)

    Hrycushko, B; Medin, P [UT Southwestern Medical Center, Dallas, TX (United States)

    2016-06-15

    Purpose: The incidence of peripheral neuropathy has risen with increased utilization of SAbR. There is no consensus regarding the dose-tolerance of the peripheral nervous system. In 2015, we commenced an investigation to test the hypotheses that single-session irradiation to the pig spinal nerves exhibit a similar dose-tolerance as that of the spinal cord and that a dose-length effect exists. This work evaluates the direct application of small animal NTCP models to both large animal spinal cord and preliminary peripheral nerve data. Methods: To date, 16 of 25 Yucatan minipigs have received single-session SAbR to a 1.5cm length and 4 of 25 have received irradiation to a 0.5cm length of left-sided C6-C8 spinal nerves. Toxicity related gait change has been observed in 13 animals (9 from the long length group and 4 from the short). This preliminary data is overlaid on several dose-response models which have been fit to rodent spinal cord tolerance experiments. Model parameters define a toxicity profile between a completely serial or parallel behaving organ. Adequacy of model application, including how length effects are handled, to published minipig spinal cord dose-response data and to preliminary peripheral nerve response data was evaluated through residual analysis. Results: No rodent-derived dose-response models were directly applicable to all pig data for the different lengths irradiated. Several models fit the long-length irradiated spinal cord data well, with the more serial-like models fitting best. Preliminary data on the short-length irradiation suggests no length effect exists, disproving our hypothesis. Conclusion: Direct application of small-animal NTCP models to pig data suggests dose-length effect predictions from small animal data may not translate clinically. However, the small animal models used have not considered dose heterogeneity and it is expected that including the low-to-mid dose levels in the penumbral region will improve this match. This work

  19. WE-AB-207B-10: On Spinal Nerve Toxicity from Single-Session SAbR in Pigs and the Translation of Small Animal NTCP Models

    International Nuclear Information System (INIS)

    Hrycushko, B; Medin, P

    2016-01-01

    Purpose: The incidence of peripheral neuropathy has risen with increased utilization of SAbR. There is no consensus regarding the dose-tolerance of the peripheral nervous system. In 2015, we commenced an investigation to test the hypotheses that single-session irradiation to the pig spinal nerves exhibit a similar dose-tolerance as that of the spinal cord and that a dose-length effect exists. This work evaluates the direct application of small animal NTCP models to both large animal spinal cord and preliminary peripheral nerve data. Methods: To date, 16 of 25 Yucatan minipigs have received single-session SAbR to a 1.5cm length and 4 of 25 have received irradiation to a 0.5cm length of left-sided C6-C8 spinal nerves. Toxicity related gait change has been observed in 13 animals (9 from the long length group and 4 from the short). This preliminary data is overlaid on several dose-response models which have been fit to rodent spinal cord tolerance experiments. Model parameters define a toxicity profile between a completely serial or parallel behaving organ. Adequacy of model application, including how length effects are handled, to published minipig spinal cord dose-response data and to preliminary peripheral nerve response data was evaluated through residual analysis. Results: No rodent-derived dose-response models were directly applicable to all pig data for the different lengths irradiated. Several models fit the long-length irradiated spinal cord data well, with the more serial-like models fitting best. Preliminary data on the short-length irradiation suggests no length effect exists, disproving our hypothesis. Conclusion: Direct application of small-animal NTCP models to pig data suggests dose-length effect predictions from small animal data may not translate clinically. However, the small animal models used have not considered dose heterogeneity and it is expected that including the low-to-mid dose levels in the penumbral region will improve this match. This work

  20. Xanthine Oxidase Activity Is Associated with Risk Factors for Cardiovascular Disease and Inflammatory and Oxidative Status Markers in Metabolic Syndrome: Effects of a Single Exercise Session

    Directory of Open Access Journals (Sweden)

    Ana Maria Pandolfo Feoli

    2014-01-01

    Full Text Available Objective. The main goal of the present study was to investigate the xanthine oxidase (XO activity in metabolic syndrome in subjects submitted to a single exercise session. We also investigated parameters of oxidative and inflammatory status. Materials/Methods. A case-control study (9 healthy and 8 MS volunteers was performed to measure XO, superoxide dismutase (SOD, glutathione peroxidase activities, lipid peroxidation, high-sensitivity C-reactive protein (hsCRP content, glucose levels, and lipid profile. Body mass indices, abdominal circumference, systolic and diastolic blood pressure, and TG levels were also determined. The exercise session consisted of 3 minutes of stretching, 3 minutes of warm-up, 30 minutes at a constant dynamic workload at a moderate intensity, and 3 minutes at a low speed. The blood samples were collected before and 15 minutes after the exercise session. Results. Serum XO activity was higher in MS group compared to control group. SOD activity was lower in MS subjects. XO activity was correlated with SOD, abdominal circumference, body mass indices, and hsCRP. The single exercise session reduced the SOD activity in the control group. Conclusions. Our data support the association between oxidative stress and risk factors for cardiovascular diseases and suggest XO is present in the pathogenesis of metabolic syndrome.

  1. Percutaneous Treatment of Simple Hepatic Cysts: The Long-Term Results of PAIR and Catheterization Techniques as Single-Session Procedures

    Energy Technology Data Exchange (ETDEWEB)

    Akhan, Okan, E-mail: akhano@tr.net [Hacettepe University Faculty of Medicine, Department of Radiology (Turkey); Islim, Filiz, E-mail: fislim@yahoo.com [Istanbul Bakirkoy Dr. Sadi Konuk Training and Research Hospital, Department of Radiology (Turkey); Balci, Sinan, E-mail: snnbalci@gmail.com [Hacettepe University Faculty of Medicine, Department of Radiology (Turkey); Erbahceci, Aysun, E-mail: aysunerbahceci@yahoo.com [Istanbul Bakirkoy Dr. Sadi Konuk Training and Research Hospital, Department of Radiology (Turkey); Akpınar, Burcu, E-mail: burcu-akpinar@yahoo.com; Ciftci, Turkmen, E-mail: turkmenciftci@yahoo.com; Akinci, Devrim, E-mail: akincid@hotmail.com [Hacettepe University Faculty of Medicine, Department of Radiology (Turkey)

    2016-06-15

    PurposeThe purpose of our study is to evaluate results of percutaneous aspiration with alcohol sclerotherapy in symptomatic patients with simple hepatic cysts by employing single-session techniques either by a needle or a catheter.Materials and MethodsWe retrospectively included 39 simple hepatic cysts in 35 patients treated via percutaneous aspiration and single-session alcohol sclerotherapy between years 1993 and 2012. Indications were pain (n = 28) or ruling out cystic echinococcus (CE) disease (n = 7). 29 cysts in 26 patients were treated by needle technique (Group A) and ten cysts in nine patients were treated by single-session catheter technique (Group B). Patients were followed for 4–173 months (median: 38 months).ResultsAll patients were successfully treated. Before procedure, cyst volumes were 21–676 cc (median: 94 cc). Post-procedure cyst volumes at last follow-up were 0-40 cc (median: 1 cc). The mean decrease in cyst volume was 95.92 ± 2.86 % in all patients (95.96 ± 3.26 % in Group A and 95.80 ± 6.20 % in Group B). There was no statistically significant difference between the volume reduction rates of Group A and Group B. Only one patient, in Group B, developed a major complication, an abscess. Hospitalization period was 1 day for all patients.ConclusionsFor patients with symptomatic simple hepatic cysts smaller than 500 cc in volume by using puncture, aspiration, injection, and reaspiration (PAIR) technique with only needle, single-session alcohol sclerotherapy of 10 min is a safe and effective procedure with high success rate.

  2. Does a single session of electroconvulsive therapy alter the neural response to emotional faces in depression? A randomised sham-controlled functional magnetic resonance imaging study.

    Science.gov (United States)

    Miskowiak, Kamilla W; Kessing, Lars V; Ott, Caroline V; Macoveanu, Julian; Harmer, Catherine J; Jørgensen, Anders; Revsbech, Rasmus; Jensen, Hans M; Paulson, Olaf B; Siebner, Hartwig R; Jørgensen, Martin B

    2017-09-01

    Negative neurocognitive bias is a core feature of major depressive disorder that is reversed by pharmacological and psychological treatments. This double-blind functional magnetic resonance imaging study investigated for the first time whether electroconvulsive therapy modulates negative neurocognitive bias in major depressive disorder. Patients with major depressive disorder were randomised to one active ( n=15) or sham electroconvulsive therapy ( n=12). The following day they underwent whole-brain functional magnetic resonance imaging at 3T while viewing emotional faces and performed facial expression recognition and dot-probe tasks. A single electroconvulsive therapy session had no effect on amygdala response to emotional faces. Whole-brain analysis revealed no effects of electroconvulsive therapy versus sham therapy after family-wise error correction at the cluster level, using a cluster-forming threshold of Z>3.1 ( p2.3; pelectroconvulsive therapy-induced changes in parahippocampal and superior frontal responses to fearful versus happy faces as well as in fear-specific functional connectivity between amygdala and occipito-temporal regions. Across all patients, greater fear-specific amygdala - occipital coupling correlated with lower fear vigilance. Despite no statistically significant shift in neural response to faces after a single electroconvulsive therapy session, the observed trend changes after a single electroconvulsive therapy session point to an early shift in emotional processing that may contribute to antidepressant effects of electroconvulsive therapy.

  3. Review Sessions and Results: Competency Testing in the Capstone Business Class

    Science.gov (United States)

    Parente, Diane H.; Brown, Randy C.; Warner, Alfred G.

    2005-01-01

    Capstone is defined in the dictionary as "putting the final stone in place." Business Policy or Strategic Management is typically the capstone class in a business management degree program. As such, there are prerequisite requirements in terms of courses and specific knowledge. We have implemented a competency test for the capstone class and…

  4. 49 CFR 238.311 - Single car test.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Single car test. 238.311 Section 238.311... Requirements for Tier I Passenger Equipment § 238.311 Single car test. (a) Except for self-propelled passenger cars, single car tests of all passenger cars and all unpowered vehicles used in passenger trains shall...

  5. Effects of a Single-Session Cognitive Enhancement Fitness Program on Serum Brain-Derived Neurotrophic Factor Levels and Cognitive Function in Middle-Aged Women

    Directory of Open Access Journals (Sweden)

    Hyun Jun Kim, Sang Yeoup Lee, Hwa Gyeong Lee, Yang Hee Cho, Eun Mi Ko

    2018-03-01

    Full Text Available Few studies have been undertaken to develop cognitive functional improvement-focused exercise programs and determine their effect. The objectives of this study were to evaluate the effects of a cognitive enhancement fitness program (CEFP on short-term memory and serum brain-derived neurotrophic factor (BDNF levels according to the cognitive state in middle-aged women. A total of 30 healthy volunteers aged 40–59 years were divided into two groups, that is, a mild cognitive impairment (MCI group and a non-MCI group based on results from the Korean Dementia Screening Questionnaire. A single-session CEFP was conducted over 50 min and consisted of four parts: warm-up, low intensity interval circulation dance exercises, moderate intensity resistance exercises using elastic bands, and cool-down. Serum BDNF levels were measured by ELISA and short-term memory determined by forward digit/word span test was assessed before and after CEFP. After CEFP, forward digit/word span test scores and BDNF levels increased to median 119.2%/115.1% and 118.7%, respectively. After CEFP, the MCI and non-MCI groups produced higher forward digit span test scores (from 6.7 ± 1.5 to 7.5 ± 1.4 points, p = 0.023 and from 6.2 ± 2.0 to 7.0 ± 2.1 points, P=0.011, respectively. After CEFP, forward word span scores and BDNF levels increased (from 3.5 ± 1.7 to 4.6 ± 1.8 points, p = 0.029 and from 610.8 ± 221.1 to 757.9 ± 267.9 pg/ml, p = 0.017, respectively in non-MCI group only. No group differences were observed between change in short-term memory and change in BDNF. Short-term memory and BDNF levels after CEFP were found to be negatively correlated with age, but pre- to post-intervention changes in short-term memory and BDNF were not. The present study shows that a single, 50-minute CEFP improved short-term memory and increased serum BDNF levels in healthy middle-aged women, especially those without MCI.

  6. Repetitive sessions of formative self-testing to refresh CPR skills: a randomised non-inferiority trial.

    Science.gov (United States)

    Mpotos, Nicolas; De Wever, Bram; Cleymans, Nick; Raemaekers, Joris; Loeys, Tom; Herregods, Luc; Valcke, Martin; Monsieurs, Koenraad G

    2014-09-01

    To investigate whether repetitive sessions of formative self-testing (RFST) result in an equal cardiopulmonary resuscitation (CPR) skill level compared to repetitive sessions of formative self-testing with additional practice (RFSTAP). In a non-inferiority trial, 196 third-year medical students were randomised to an RFST or RFSTAP group. Testing and practising took place in a self-learning station equipped with a manikin connected to a computer. Each cycle of RFST consisted of a 2-min CPR test followed by feedback and feedforward. In the RFSTAP group, additional practice consisted of CPR exercises with a computer voice feedback. To be successful, a combined score consisting of ≥70% compressions with a depth of ≥50 mm and ≥70% compressions with complete release (<5 mm) and a compression rate of 100-120 min(-1) and ≥70% ventilations with a volume of 400-1000 ml had to be achieved within 6 weeks. Skill retention was measured after 6 months. The non-inferiority margin was predefined as a 10% difference in success rate. After six weeks the success rate in both groups was 96%: 99/103 (RFST) and 89/93 (RFSTAP). After 6 months, the success rate in the competent students was 26/96 (27%) for RFST and 32/86 (37%) for RFSTAP (three students dropped out in each group). The difference in the success rate between RFSTAP and RFST was 10% and 90% (CI -2 to 23%), respectively. As the upper bound exceeded 10%, non-inferiority was inconclusive. For each CPR skill separately, RFST was non-inferior for ventilation and complete release, superior for compression depth and inferior for compression rate. RFST and RFSTAP were equally effective to refresh skills within 6 weeks. After 6 months, non-inferiority was inconclusive for the combined score. Our results indicate the potential of RFST to refresh CPR skills. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  7. Effectiveness of Single Session of Low-Level Laser Therapy with a 940 nm Wavelength Diode Laser on Pain, Swelling, and Trismus After Impacted Third Molar Surgery.

    Science.gov (United States)

    Eroglu, Cennet Neslihan; Keskin Tunc, Serap

    2016-09-01

    In low-level laser therapy (LLLT), applications are generally performed in repetitive sessions using wavelengths of around 800 nm, at which the depth of penetration of laser is greater. The present study aimed to investigate the effects of LLLT with a 940 nm diode laser, which was performed extraorally on all the primarily and secondarily affected areas immediately after surgery in a single session, on pain, swelling, and trismus that occurred after impacted tooth extraction. Thirty-five outpatients with similarly impacted lower third molars on both sides were selected. The teeth of patients were removed in two separate operations. Postoperatively, the patients received laser therapy with energy of 4 J/cm(2) on one side and no laser energy was applied to the other side (placebo side). Swelling, trismus, and subjective assessment of pain on a visual analog scale were evaluated and compared between the laser-treated and placebo sides. There was no statistically significant difference in pain, swelling, or trismus between the sides (Mann-Whitney U test p > 0.05). However, according to the clinical outcomes, swelling and trismus were less in the laser-treated side than in the placebo side. A single-session LLLT that would be applied with a diode laser immediately after impacted tooth extraction might help patients to be less affected by postoperative trismus and swelling.

  8. Single-Session Transcranial Direct Current Stimulation Temporarily Improves Symptoms, Mood, and Self-Regulatory Control in Bulimia Nervosa: A Randomised Controlled Trial.

    Directory of Open Access Journals (Sweden)

    Maria Kekic

    Full Text Available Evidence suggests that pathological eating behaviours in bulimia nervosa (BN are underpinned by alterations in reward processing and self-regulatory control, and by functional changes in neurocircuitry encompassing the dorsolateral prefrontal cortex (DLPFC. Manipulation of this region with transcranial direct current stimulation (tDCS may therefore alleviate symptoms of the disorder.This double-blind sham-controlled proof-of-principle trial investigated the effects of bilateral tDCS over the DLPFC in adults with BN.Thirty-nine participants (two males received three sessions of tDCS in a randomised and counterbalanced order: anode right/cathode left (AR/CL, anode left/cathode right (AL/CR, and sham. A battery of psychological/neurocognitive measures was completed before and after each session and the frequency of bulimic behaviours during the following 24-hours was recorded.AR/CL tDCS reduced eating disorder cognitions (indexed by the Mizes Eating Disorder Cognitions Questionnaire-Revised when compared to AL/CR and sham tDCS. Both active conditions suppressed the self-reported urge to binge-eat and increased self-regulatory control during a temporal discounting task. Compared to sham stimulation, mood (assessed with the Profile of Mood States improved after AR/CL but not AL/CR tDCS. Lastly, the three tDCS sessions had comparable effects on the wanting/liking of food and on bulimic behaviours during the 24 hours post-stimulation.These data suggest that single-session tDCS transiently improves symptoms of BN. They also help to elucidate possible mechanisms of action and highlight the importance of selecting the optimal electrode montage. Multi-session trials are needed to determine whether tDCS has potential for development as a treatment for adult BN.

  9. Single-Session Transcranial Direct Current Stimulation Temporarily Improves Symptoms, Mood, and Self-Regulatory Control in Bulimia Nervosa: A Randomised Controlled Trial.

    Science.gov (United States)

    Kekic, Maria; McClelland, Jessica; Bartholdy, Savani; Boysen, Elena; Musiat, Peter; Dalton, Bethan; Tiza, Meyzi; David, Anthony S; Campbell, Iain C; Schmidt, Ulrike

    2017-01-01

    Evidence suggests that pathological eating behaviours in bulimia nervosa (BN) are underpinned by alterations in reward processing and self-regulatory control, and by functional changes in neurocircuitry encompassing the dorsolateral prefrontal cortex (DLPFC). Manipulation of this region with transcranial direct current stimulation (tDCS) may therefore alleviate symptoms of the disorder. This double-blind sham-controlled proof-of-principle trial investigated the effects of bilateral tDCS over the DLPFC in adults with BN. Thirty-nine participants (two males) received three sessions of tDCS in a randomised and counterbalanced order: anode right/cathode left (AR/CL), anode left/cathode right (AL/CR), and sham. A battery of psychological/neurocognitive measures was completed before and after each session and the frequency of bulimic behaviours during the following 24-hours was recorded. AR/CL tDCS reduced eating disorder cognitions (indexed by the Mizes Eating Disorder Cognitions Questionnaire-Revised) when compared to AL/CR and sham tDCS. Both active conditions suppressed the self-reported urge to binge-eat and increased self-regulatory control during a temporal discounting task. Compared to sham stimulation, mood (assessed with the Profile of Mood States) improved after AR/CL but not AL/CR tDCS. Lastly, the three tDCS sessions had comparable effects on the wanting/liking of food and on bulimic behaviours during the 24 hours post-stimulation. These data suggest that single-session tDCS transiently improves symptoms of BN. They also help to elucidate possible mechanisms of action and highlight the importance of selecting the optimal electrode montage. Multi-session trials are needed to determine whether tDCS has potential for development as a treatment for adult BN.

  10. A randomized, placebo-controlled double-blinded comparative clinical study of five over-the-counter non-pharmacological topical analgesics for myofascial pain: single session findings

    Directory of Open Access Journals (Sweden)

    Avrahami Daniel

    2012-03-01

    Full Text Available Abstract Objectives To investigate the effects of topical agents for the treatment of Myofascial Pain Syndrome (MPS and Myofascial Trigger Point (MTRP. Methods Subjects with an identifiable trigger point in the trapezius muscle, age 18-80 were recruited for a single-session randomized, placebo-blinded clinical study. Baseline measurements of trapezius muscle pressure pain threshold (PPT: by pressure algometer along with right and left cervical lateral flexion (rangiometer were obtained by a blinded examiner. An assessor blinded to the outcomes assessments applied one of 6 topical formulations which had been placed in identical plastic containers. Five of these topicals were proposed active formulations; the control group was given a non-active formulation (PLA. Five minutes after the application of the formula the outcome measures were re-tested. Data were analyzed with a 5-way ANOVA and Holms-adjusted t-tests with an alpha level of 0.05. Results 120 subjects were entered into the study (63 females; ages 16-82; 20 subjects randomly allocated into each group. The pre- and post-treatment results for pressure threshold did show significant intra-group increases for the Ben-Gay Ultra Strength Muscle Pain Ointment (BG, the Professional Therapy MuscleCare Roll-on (PTMC roll-on and Motion Medicine Cream (MM with an increased threshold of 0.5 kg/cm2 (+/-0.15, 0.72 kg/cm2 (+/-0.17 and 0.47 Kg/cm2 (+/-0.19 respectively. With respect to the inter-group comparisons, PTMC roll-on showed significant increases in pressure threshold compared with Placebo (PLA (p = 0.002 and Icy Hot Extra Strength Cream (IH (p = 0.006. In addition, BG demonstrated significant increases in pressure threshold compared with PLA (p = 0.0003. Conclusions With regards to pressure threshold, PTMC roll-on, BG and MM showed significant increases in pain threshold tolerance after a short-term application on a trigger points located in the trapezius muscle. PTMC roll-on and BG were both

  11. Can a Single Session of a Community-Based Group Exercise Program Combining Step Aerobics and Bodyweight Resistance Exercise Acutely Reduce Blood Pressure?

    Directory of Open Access Journals (Sweden)

    Mendes Romeu

    2014-12-01

    Full Text Available This study aimed to analyze the acute effects of a single session of a community-based group exercise program combining step aerobics and bodyweight resistance exercise on blood pressure in healthy young adult women. Twentythree healthy young adult women (aged 31.57 ± 7.87 years participated in two experimental sessions (exercise and control in a crossover study design. Blood pressure was monitored before, immediately after and at 10, 20 and 30 min of recovery. The exercise session consisted of four phases: 1 a warm-up (5 min of dance aerobics; 2 aerobic exercise training (30 min of step aerobics; 3 resistance exercise training (six sets of 12 repetitions of three bodyweight exercises in a circuit mode, 10 min; and 4 a cool-down (5 min of breathing and flexibility exercises; totaling 50 min of duration. Systolic blood pressure after exercise was significantly lower compared to control at the 10th min (-10.83 ± 2.13 vs. -2.6 ± 2.13 mmHg; p = 0.009, 20th min (-11.26 ± 2.13 vs. -3.04 ± 2.13 mmHg; p = 0.009 and 30th min of recovery (-10.87 ± 2.39 vs. -0.48 ± 2.39 mmHg; p = 0.004. A single session of a community-based group exercise program combining step aerobics and bodyweight resistance exercise was effective in inducing significant post-exercise hypotension in healthy young adult women. This type of low-cost exercise interventions may have an important role in the prevention of cardiovascular diseases and in community health promotion.

  12. Effect of a single session of ear acupuncture on pain intensity and postural control in individuals with chronic low back pain: a randomized controlled trial

    Directory of Open Access Journals (Sweden)

    Andrea Ushinohama

    2016-01-01

    Full Text Available ABSTRACT Background Ear Acupuncture (EA is a form of acupuncture in which needles are applied to the external ear and has been used in multiple painful conditions. Low back pain (LBP is highly prevalent in active individuals and causes high economic burden to health systems worldwide. LBP affects the person’s ability to keep balance, especially in challenging conditions. Objective The aim of the study was to examine the effects of a single session of EA on pain intensity and body sway during postural tasks. Method Eighty adults with LBP and pain intensity equal to or greater than 4 (0-10 scale were randomly allocated (1:1 to EA group (EAG or placebo group (PG. Initially, the level of pain intensity was assessed. Next, participants stood still on a force plate either with feet in parallel or in semi-tandem and with eyes open or closed. Then, the EAG was treated with EA for 20 min and the PG was treated with detuned ultrasound. After the treatment, pain intensity was assessed again and the postural test was repeated. Pain intensity was the primary outcome and center of pressure sway area and speed were the secondary outcomes measured. Results Results revealed that pain intensity decreased in both groups after treatment, but decreased more in the EAG. For postural control, no effect of treatment and no interaction between treatment and postural condition on body sway were found. Conclusion Those findings indicate that EA is better than placebo to reduce pain, but neither treatment has any effect on postural control.

  13. Proceedings of the Third NRC/ASME Symposium on Valve and Pump Testing. Volume 2, Session 3A--Session 4B

    Energy Technology Data Exchange (ETDEWEB)

    1994-07-01

    The 1994 Symposium on Valve and Pump Testing, jointly sponsored by the Board of Nuclear Codes and Standards of the American Society of Mechanical Engineers and by the Nuclear Regulatory Commission, provides a forum for the discussion of current programs and methods for inservice testing and motor-operated valve testing at nuclear power plants. The symposium also provides an opportunity to discuss the need to improve that testing in order to help ensure the reliable performance of pumps and valves. The participation of industry representatives, regulators, and consultants results in the discussion of a broad spectrum of ideas and perspectives regarding the improvement of inservice testing of pumps and valves at nuclear power plants. Individual papers have been cataloged separately.

  14. Panel Session

    DEFF Research Database (Denmark)

    Bertelsen, Olav Wedege

    2004-01-01

    In this panel session, four researchers will discuss the role of a theoretical foundation, in particular AT, in the design of information technology based artefacts. The general discussion will take of from a specific examination of the ActAD approach.......In this panel session, four researchers will discuss the role of a theoretical foundation, in particular AT, in the design of information technology based artefacts. The general discussion will take of from a specific examination of the ActAD approach....

  15. Balance maintenance as an acquired motor skill: Delayed gains and robust retention after a single session of training in a virtual environment.

    Science.gov (United States)

    Elion, Orit; Sela, Itamar; Bahat, Yotam; Siev-Ner, Itzhak; Weiss, Patrice L Tamar; Karni, Avi

    2015-06-03

    Does the learning of a balance and stability skill exhibit time-course phases and transfer limitations characteristic of the acquisition and consolidation of voluntary movement sequences? Here we followed the performance of young adults trained in maintaining balance while standing on a moving platform synchronized with a virtual reality road travel scene. The training protocol included eight 3 min long iterations of the road scene. Center of Pressure (CoP) displacements were analyzed for each task iteration within the training session, as well as during tests at 24h, 4 weeks and 12 weeks post-training to test for consolidation phase ("offline") gains and assess retention. In addition, CoP displacements in reaction to external perturbations were assessed before and after the training session and in the 3 subsequent post-training assessments (stability tests). There were significant reductions in CoP displacements as experience accumulated within session, with performance stabilizing by the end of the session. However, CoP displacements were further reduced at 24h post-training (delayed "offline" gains) and these gains were robustly retained. There was no transfer of the practice-related gains to performance in the stability tests. The time-course of learning the balance maintenance task, as well as the limitation on generalizing the gains to untrained conditions, are in line with the results of studies of manual movement skill learning. The current results support the conjecture that a similar repertoire of basic neuronal mechanisms of plasticity may underlay skill (procedural, "how to" knowledge) acquisition and skill memory consolidation in voluntary and balance maintenance tasks. Copyright © 2015 Elsevier B.V. All rights reserved.

  16. A Single Session of rTMS Enhances Small-Worldness in Writer’s Cramp: Evidence from Simultaneous EEG-fMRI Multi-Modal Brain Graph

    Directory of Open Access Journals (Sweden)

    Rose D. Bharath

    2017-09-01

    Full Text Available Background and Purpose: Repetitive transcranial magnetic stimulation (rTMS induces widespread changes in brain connectivity. As the network topology differences induced by a single session of rTMS are less known we undertook this study to ascertain whether the network alterations had a small-world morphology using multi-modal graph theory analysis of simultaneous EEG-fMRI.Method: Simultaneous EEG-fMRI was acquired in duplicate before (R1 and after (R2 a single session of rTMS in 14 patients with Writer’s Cramp (WC. Whole brain neuronal and hemodynamic network connectivity were explored using the graph theory measures and clustering coefficient, path length and small-world index were calculated for EEG and resting state fMRI (rsfMRI. Multi-modal graph theory analysis was used to evaluate the correlation of EEG and fMRI clustering coefficients.Result: A single session of rTMS was found to increase the clustering coefficient and small-worldness significantly in both EEG and fMRI (p < 0.05. Multi-modal graph theory analysis revealed significant modulations in the fronto-parietal regions immediately after rTMS. The rsfMRI revealed additional modulations in several deep brain regions including cerebellum, insula and medial frontal lobe.Conclusion: Multi-modal graph theory analysis of simultaneous EEG-fMRI can supplement motor physiology methods in understanding the neurobiology of rTMS in vivo. Coinciding evidence from EEG and rsfMRI reports small-world morphology for the acute phase network hyper-connectivity indicating changes ensuing low-frequency rTMS is probably not “noise”.

  17. Effectiveness of a brief school-based body image intervention 'Dove Confident Me: Single Session' when delivered by teachers and researchers: Results from a cluster randomised controlled trial.

    Science.gov (United States)

    Diedrichs, Phillippa C; Atkinson, Melissa J; Steer, Rebecca J; Garbett, Kirsty M; Rumsey, Nichola; Halliwell, Emma

    2015-11-01

    This study evaluated a 90-min single session school-based body image intervention (Dove Confident Me: Single Session), and investigated if delivery could be task-shifted to teachers. British adolescents (N = 1707; 11-13 years; 50.83% girls) participated in a cluster randomised controlled trial [lessons as usual control; intervention teacher-led (TL); intervention researcher-led (RL)]. Body image, risk factors, and psychosocial and disordered eating outcomes were assessed 1-week pre-intervention, immediate post-intervention, and 4-9.5 weeks follow-up. Multilevel mixed-models showed post-intervention improvements for intervention students relative to control in body esteem (TL; girls only), negative affect (TL), dietary restraint (TL; girls only), eating disorder symptoms (TL), and life engagement (TL; RL). Awareness of sociocultural pressures increased at post-intervention (TL). Effects were small-medium in size (ds 0.19-0.76) and were not maintained at follow-up. There were no significant differences between conditions at post or follow-up on body satisfaction, appearance comparisons, teasing, appearance conversations and self-esteem. The intervention had short-term benefits for girls' body image and dietary restraint, and for eating disorder symptoms and some psychosocial outcomes among girls and boys. A multi-session version of the intervention is likely to be necessary for sustained improvements. Teachers can deliver this intervention effectively with minimal training, indicating broader scale dissemination is feasible. ISRCTN16782819. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.

  18. Effect of a single session of transcranial direct-current stimulation on balance and spatiotemporal gait variables in children with cerebral palsy: A randomized sham-controlled study

    Directory of Open Access Journals (Sweden)

    Luanda A. C. Grecco

    2014-10-01

    Full Text Available Background: Transcranial direct-current stimulation (tDCS has been widely studied with the aim of enhancing local synaptic efficacy and modulating the electrical activity of the cortex in patients with neurological disorders. Objective: The purpose of the present study was to determine the effect of a single session of tDCS regarding immediate changes in spatiotemporal gait and oscillations of the center of pressure (30 seconds in children with cerebral palsy (CP. Method: A randomized controlled trial with a blinded evaluator was conducted involving 20 children with CP between six and ten years of age. Gait and balance were evaluated three times: Evaluation 1 (before the stimulation, Evaluation 2 (immediately after stimulation, and Evaluation 3 (20 minutes after the stimulation. The protocol consisted of a 20-minute session of tDCS applied to the primary motor cortex at an intensity of 1 mA. The participants were randomly allocated to two groups: experimental group - anodal stimulation of the primary motor cortex; and control group - placebo transcranial stimulation. Results: Significant reductions were found in the experimental group regarding oscillations during standing in the anteroposterior and mediolateral directions with eyes open and eyes closed in comparison with the control group (p<0.05. In the intra-group analysis, the experimental group exhibited significant improvements in gait velocity, cadence, and oscillation in the center of pressure during standing (p<0.05. No significant differences were found in the control group among the different evaluations. Conclusion: A single session of tDCS applied to the primary motor cortex promotes positive changes in static balance and gait velocity in children with cerebral palsy.

  19. Single Event Testing on Complex Devices: Test Like You Fly versus Test-Specific Design Structures

    Science.gov (United States)

    Berg, Melanie; LaBel, Kenneth A.

    2014-01-01

    We present a framework for evaluating complex digital systems targeted for harsh radiation environments such as space. Focus is limited to analyzing the single event upset (SEU) susceptibility of designs implemented inside Field Programmable Gate Array (FPGA) devices. Tradeoffs are provided between application-specific versus test-specific test structures.

  20. The Effect of a Single Session of Whole-Body Vibration Training in Recreationally Active Men on the Excitability of the Central and Peripheral Nervous System

    Directory of Open Access Journals (Sweden)

    Chmielewska Daria

    2014-07-01

    Full Text Available Vibration training has become a popular method used in professional sports and recreation. In this study, we examined the effect of whole-body vibration training on the central nervous system and muscle excitability in a group of 28 active men. Subjects were assigned randomly to one of two experimental groups with different variables of vibrations. The chronaximetry method was used to evaluate the effect of a single session of whole-body vibration training on the excitability of the rectus femoris and brachioradialis muscles. The examination of the fusing and flickering frequencies of the light stimulus was performed. An increase in the excitability of the quadriceps femoris muscle due to low intensity vibrations (20 Hz frequency, 2 mm amplitude was noted, and a return to the initial values was observed 30 min after the application of vibration. High intensity vibrations (60 Hz frequency, 4 mm amplitude caused elongations of the chronaxy time; however, these differences were not statistically significant. Neither a low intensity vibration amplitude of 2 mm (frequency of 20 Hz nor a high intensity vibration amplitude of 4 mm (frequency of 60 Hz caused a change in the excitability of the central nervous system, as revealed by the average frequency of the fusing and flickering of the light stimulus. A single session of high intensity whole-body vibration did not significantly decrease the excitability of the peripheral nervous system while the central nervous system did not seem to be affected.

  1. Whole body oxygen uptake and evoked torque during subtetanic isometric electrical stimulation of the quadriceps muscles in a single 30-minute session.

    Science.gov (United States)

    Minogue, Conor M; Caulfield, Brian M; Lowery, Madeleine M

    2014-09-01

    To evaluate the time course of fatigue in torque output and oxygen uptake during isometric subtetanic neuromuscular electrical stimulation (NMES) to facilitate the design of NMES-based rehabilitation protocols that can accumulate a defined aerobic exercise volume within a given time period. Single-arm intervention study with within-subject comparisons. University research laboratory. Volunteer sample of healthy men (N=11; mean age, 34.2 ± 11.5 y; range, 19-53 y; body mass, 79.1 ± 11.7 kg; range, 58-100 kg). A single 30-minute session of continuous bilateral isometric quadriceps NMES at 4 Hz evoking a mean twitch amplitude of 12% of the maximum voluntary contraction. Whole body oxygen consumption rate (V˙o2), and evoked torque were measured simultaneously throughout. Mean increment in V˙o2 was 596 ± 238 mL/min, and average exercise intensity during the session was 3 ±.47 metabolic equivalents. The V˙o2 and torque declined slowly at a rate of -.54%±.31% and -.47%±.57% per minute, respectively. Despite having a higher incremental V˙o2, the observed fatigue rate was considerably less than that previously reported during intermittent isometric tetanic stimulation, suggesting that subtetanic isometric NMES is more sustainable for exercise interventions aimed at accumulating a therapeutic aerobic exercise volume. Copyright © 2014 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  2. Does a single session of theta-burst transcranial magnetic stimulation of inferior temporal cortex affect tinnitus perception?

    Directory of Open Access Journals (Sweden)

    Moser Tobias

    2009-05-01

    Full Text Available Abstract Background Cortical excitability changes as well as imbalances in excitatory and inhibitory circuits play a distinct pathophysiological role in chronic tinnitus. Repetitive transcranial magnetic stimulation (rTMS over the temporoparietal cortex was recently introduced to modulate tinnitus perception. In the current study, the effect of theta-burst stimulation (TBS, a novel rTMS paradigm was investigated in chronic tinnitus. Twenty patients with chronic tinnitus completed the study. Tinnitus severity and loudness were monitored using a tinnitus questionnaire (TQ and a visual analogue scale (VAS before each session. Patients received 600 pulses of continuous TBS (cTBS, intermittent TBS (iTBS and intermediate TBS (imTBS over left inferior temporal cortex with an intensity of 80% of the individual active or resting motor threshold. Changes in subjective tinnitus perception were measured with a numerical rating scale (NRS. Results TBS applied to inferior temporal cortex appeared to be safe. Although half of the patients reported a slight attenuation of tinnitus perception, group analysis resulted in no significant difference when comparing the three specific types of TBS. Converting the NRS into the VAS allowed us to compare the time-course of aftereffects. Only cTBS resulted in a significant short-lasting improvement of the symptoms. In addition there was no significant difference when comparing the responder and non-responder groups regarding their anamnestic and audiological data. The TQ score correlated significantly with the VAS, lower loudness indicating less tinnitus distress. Conclusion TBS does not offer a promising outcome for patients with tinnitus in the presented study.

  3. Breakout Sessions

    CERN Multimedia

    CERN. Geneva

    2004-01-01

    Participants are split into small groups for detailed discussion on their chosen topic. To register please click on 'See details' link from the agenda and then on the link to send an email to the session for which you would like to book. Please don't change the subject line of the email.

  4. Towards single screening tests for brucellosis

    DEFF Research Database (Denmark)

    Nielsen, K.; Smith, P.; Yu, W.

    2005-01-01

    This paper describes an indirect enzyme-linked immunosorbent assay (I-ELISA) and a fluorescence polarisation assay (FPA), each capable of detecting antibody in several species of hosts to smooth and rough members of the genus Brucella. The I-ELISA uses a mixture of smooth lipopolysaccharide (SLPS...... than did I-ELISA procedures using each individual antigen separately. Similarly, the assay using combined antigens detected antibody in slightly fewer animals not exposed to Brucella sp. When a universal cutoff of 10% positivity was used (relative to strongly positive control sera of each species......-ELISA and the FPA with combined antigens were suitable as screening tests for all species of Brucella in the animal species tested....

  5. Does a single session of high-intensity interval training provoke a transient elevated risk of falling in seniors and adults?

    Science.gov (United States)

    Donath, Lars; Kurz, Eduard; Roth, Ralf; Hanssen, Henner; Schmidt-Trucksäss, Arno; Zahner, Lukas; Faude, Oliver

    2015-01-01

    Balance and strength training can reduce seniors' fall risk up to 50%. Available evidence suggests that acute bouts of neuromuscular and endurance exercise deteriorate postural control. High-intensity endurance training has been successfully applied in different populations. Thus, it seemed valuable to examine the acute effects of high-intensity interval training (HIIT) on neuromuscular performance in seniors and young adults. The acute impact of a HIIT session on balance performance and muscle activity after exercise cessation and during post-exercise recovery was examined in young and old adults. We intended to investigate whether a transient exercise-induced fall-risk may occur in both groups. 20 healthy seniors (age 70 (SD 4) years) and young adults (age 27 (SD 3) years) were examined on 3 days. After exhaustive ramp-like treadmill testing in order to determine maximal heart rate (HRmax) on the first day, either a 4 × 4 min HIIT at 90% of HRmax or a control condition (CON) was randomly performed on the second and third day, respectively. Balance performance (postural sway) was assessed during single limb stance with open eyes (SLEO) and double limb stance with closed eyes (DLEC). EMG was recorded for the soleus (SOL), anterior tibialis (TIB), gastrocnemius (GM) and peroneus longus (PL) muscles at the dominant leg. All measures were collected before, immediately as well as 10, 30 and 45 min after HIIT and CON, respectively. Compared to CON, HIIT induced significant increases of postural sway immediately after exercise cessation during SLEO in both groups (adults: p HIIT (post: p = 0.003, Δ = +14% sway, 10 min post: p = 0.004, Δ = +18% sway). Muscle activity was increased during SLEO for TIB until 10 min post in seniors (0.008 HIIT in adults (p HIIT training may cause an acute 'open-fall-window' with a transient impairment of balance performance for at least 10 min after exercise cessation in both groups. Occluded vision in seniors seems to prolong this period

  6. A Single Session of an Integrated Yoga Program as a Stress Management Tool for School Employees: Comparison of Daily Practice and Nondaily Practice of a Yoga Therapy Program.

    Science.gov (United States)

    Nosaka, Michiyo; Okamura, Hitoshi

    2015-07-01

    The aim of this study was to assess the effect of the daily practice of a yoga therapy program learnt during a single session of an integrated yoga intervention that was developed by us as a stress management tool for school employees. Ninety school employees. Case-control study. Three months after the intervention, the subjects were assigned to a daily practice group (case: n=43) and a nonconsecutive daily practice group (control: n=47) according to their daily practice level of the yoga therapy program. The subjects participated in a stress management education program based on an integrated yoga therapy session. The program included psychological education and counseling about stress management and yoga theories, as well as the practices of asanas, pranayama, relaxation, and cognitive structure based on Indian philosophy. Assessments were performed before and after the program using the Subjective Units of Distress for mind and body and the Two-Dimensional Mood Scale. The General Health Questionnaire 28 (GHQ28) was used to assess the mental health state before the intervention and at 3 months after the program. The subjects showed significant increases in their levels of calmness, comfort, and cheerfulness (pstress (pstress and that the mental health of school employees was promoted by the daily practice of the yoga therapy program.

  7. Single session of brief electrical stimulation immediately following crush injury enhances functional recovery of rat facial nerve

    OpenAIRE

    Eileen M. Foecking, PhD; Keith N. Fargo, PhD; Lisa M. Coughlin, MD; James T. Kim, MD; Sam J. Marzo, MD; Kathryn J. Jones, PhD

    2012-01-01

    Peripheral nerve injuries lead to a variety of pathological conditions, including paresis or paralysis when the injury involves motor axons. We have been studying ways to enhance the regeneration of peripheral nerves using daily electrical stimulation (ES) following a facial nerve crush injury. In our previous studies, ES was not initiated until 24 h after injury. The current experiment tested whether ES administered immediately following the crush injury would further decrease the time for c...

  8. The effects of a resistance vs. an aerobic single session on attention and executive functioning in adults.

    Directory of Open Access Journals (Sweden)

    Ayelet Dunsky

    Full Text Available Evidence from recent studies showed that acute aerobic exercise results in improvements in different cognitive functions. The goal of this study was to assess the influence of acute bouts of aerobic versus resistance exercise on attention and executive function in adults. Thirty-nine physically active adults (age = 52±8 yr served as participants. Each participant visited the laboratory four times: on the first visit participants performed a cognitive test (NeuroTrax followed by an aerobic fitness assessment, as well as maximal strength test composed of six exercises. During visits 2-4, participants completed the cognitive test before and after the experimental condition, which consisted of either 25 min of aerobic exercise or resistance exercise, or watching a recorded interview show in a seated position (control condition. Findings indicated significantly higher changes in scores of attention after acute aerobic exercise (mean change 3.46, 95% CI -0.32, 7.27 than following the control condition (mean change -0.64, 95% CI -2.23, 0.96. The changes following resistance exercise (mean change -0.67, 95% CI -4.47, 3.13 were not significantly different from the changes following the control condition. Executive function scores showed a marginally significant improvement following acute aerobic (mean change 4.06, 95% CI 1.68, 6.44 and resistance exercise (mean change 3.69, 95% CI 0.78, 6.60, but not after control (mean change 0.91, 95% CI -1.21, 3.02. We suggest that adults should consider augmenting both modalities into their training routines, which may improve their cognition in addition to providing other physical benefits.

  9. Quantitative Review Finds No Evidence of Cognitive Effects in Healthy Populations From Single-session Transcranial Direct Current Stimulation (tDCS).

    Science.gov (United States)

    Horvath, Jared Cooney; Forte, Jason D; Carter, Olivia

    2015-01-01

    Over the last 15-years, transcranial direct current stimulation (tDCS), a relatively novel form of neuromodulation, has seen a surge of popularity in both clinical and academic settings. Despite numerous claims suggesting that a single session of tDCS can modulate cognition in healthy adult populations (especially working memory and language production), the paradigms utilized and results reported in the literature are extremely variable. To address this, we conduct the largest quantitative review of the cognitive data to date. Single-session tDCS data in healthy adults (18-50) from every cognitive outcome measure reported by at least two different research groups in the literature was collected. Outcome measures were divided into 4 broad categories: executive function, language, memory, and miscellaneous. To account for the paradigmatic variability in the literature, we undertook a three-tier analysis system; each with less-stringent inclusion criteria than the prior. Standard mean difference values with 95% CIs were generated for included studies and pooled for each analysis. Of the 59 analyses conducted, tDCS was found to not have a significant effect on any - regardless of inclusion laxity. This includes no effect on any working memory outcome or language production task. Our quantitative review does not support the idea that tDCS generates a reliable effect on cognition in healthy adults. Reasons for and limitations of this finding are discussed. This work raises important questions regarding the efficacy of tDCS, state-dependency effects, and future directions for this tool in cognitive research. Copyright © 2015 Elsevier Inc. All rights reserved.

  10. Matter over mind: a randomised-controlled trial of single-session biofeedback training on performance anxiety and heart rate variability in musicians.

    Directory of Open Access Journals (Sweden)

    Ruth Wells

    Full Text Available Musical performance is a skilled activity performed under intense pressure, thus is often a profound source of anxiety. In other contexts, anxiety and its concomitant symptoms of sympathetic nervous system arousal have been successfully ameliorated with HRV biofeedback (HRV BF, a technique involving slow breathing which augments autonomic and emotional regulatory capacity.This randomised-controlled study explored the impact of a single 30-minute session of HRV BF on anxiety in response to a highly stressful music performance.A total of 46 trained musicians participated in this study and were randomly allocated to a slow breathing with or without biofeedback or no-treatment control group. A 3 Group×2 Time mixed experimental design was employed to compare the effect of group before and after intervention on performance anxiety (STAI-S and frequency domain measures of HRV.Slow breathing groups (n=30 showed significantly greater improvements in high frequency (HF and LF/HF ratio measures of HRV relative to control (n=15 during 5 minute recordings of performance anticipation following the intervention (effect size: η(2 =0.122 and η(2 =0.116, respectively. The addition of biofeedback to a slow breathing protocol did not produce differential results. While intervention groups did not exhibit an overall reduction in self-reported anxiety, participants with high baseline anxiety who received the intervention (n=15 displayed greater reductions in self-reported state anxiety relative to those in the control condition (n=7 (r=0.379.These findings indicate that a single session of slow breathing, regardless of biofeedback, is sufficient for controlling physiological arousal in anticipation of psychosocial stress associated with music performance and that slow breathing is particularly helpful for musicians with high levels of anxiety. Future research is needed to further examine the effects of HRV BF as a low-cost, non-pharmacological treatment for

  11. A Single-Session Preliminary Evaluation of an Affordable BCI-Controlled Arm Exoskeleton and Motor-Proprioception Platform

    Science.gov (United States)

    Elnady, Ahmed Mohamed; Zhang, Xin; Xiao, Zhen Gang; Yong, Xinyi; Randhawa, Bubblepreet Kaur; Boyd, Lara; Menon, Carlo

    2015-01-01

    Traditional, hospital-based stroke rehabilitation can be labor-intensive and expensive. Furthermore, outcomes from rehabilitation are inconsistent across individuals and recovery is hard to predict. Given these uncertainties, numerous technological approaches have been tested in an effort to improve rehabilitation outcomes and reduce the cost of stroke rehabilitation. These techniques include brain–computer interface (BCI), robotic exoskeletons, functional electrical stimulation (FES), and proprioceptive feedback. However, to the best of our knowledge, no studies have combined all these approaches into a rehabilitation platform that facilitates goal-directed motor movements. Therefore, in this paper, we combined all these technologies to test the feasibility of using a BCI-driven exoskeleton with FES (robotic training device) to facilitate motor task completion among individuals with stroke. The robotic training device operated to assist a pre-defined goal-directed motor task. Because it is hard to predict who can utilize this type of technology, we considered whether the ability to adapt skilled movements with proprioceptive feedback would predict who could learn to control a BCI-driven robotic device. To accomplish this aim, we developed a motor task that requires proprioception for completion to assess motor-proprioception ability. Next, we tested the feasibility of robotic training system in individuals with chronic stroke (n = 9) and found that the training device was well tolerated by all the participants. Ability on the motor-proprioception task did not predict the time to completion of the BCI-driven task. Both participants who could accurately target (n = 6) and those who could not (n = 3), were able to learn to control the BCI device, with each BCI trial lasting on average 2.47 min. Our results showed that the participants’ ability to use proprioception to control motor output did not affect their ability to use the BCI

  12. A single robotic session that guides or increases movement error in survivors post-chronic stroke: which intervention is best to boost the learning of a timing task?

    Science.gov (United States)

    Bouchard, Amy E; Corriveau, Hélène; Milot, Marie-Hélène

    2017-08-01

    Timing deficits can have a negative impact on the lives of survivors post-chronic stroke. Studies evaluating ways to improve timing post stroke are scarce. The goal of the study was to evaluate the impact of a single session of haptic guidance (HG) and error amplification (EA) robotic training interventions on the improvement of post-stroke timing accuracy. Thirty-four survivors post-chronic stroke were randomly assigned to HG or EA. Participants played a computerized pinball-like game with their affected hand positioned in a robot that either helped them perform better (HG) or worse (EA) during the task. A baseline and retention phase preceded and followed HG and EA, respectively, in order to assess their efficiency at improving absolute timing errors. The impact of the side of the stroke lesion on the participants' performance during the timing task was also explored for each training group. An improvement in timing performance was only noted following HG (8.9 ± 4.9 ms versus 7.8 ± 5.3 ms, p = 0.032). Moreover, for the EA group only, participants with a left-sided stroke lesion showed a worsening in performance as compared to those with a right-sided stroke lesion (p = 0.001). Helping survivors post-chronic stroke perform a timing-based task is beneficial to learning. Future studies should explore longer and more frequent HG training sessions in order to further promote post stroke motor recovery. Implications for Rehabilitation Timing is crucial for the accomplishment of daily tasks. The number of studies dedicated to improving timing is scarce in the literature, even though timing deficits are common post stroke. This innovative study evaluated the impact of a single session of haptic guidance-HG and error amplification-EA robotic training interventions on improvements in timing accuracy among survivors post chronic stroke. HG robotic training improves timing accuracy more than EA among survivors post chronic stroke.

  13. Session summaries

    International Nuclear Information System (INIS)

    Sudo, Y.

    2002-01-01

    In the summary session, possible international activities in the field of basic studies on high-temperature engineering were discussed within the framework of the OECD/NEA Nuclear Science Committee (NSC). It was recommended to include topics relevant to fission-product behaviour and safety issues of HTGR in next meeting, in addition to the topics discussed in this meeting. The chairperson of the last session summarised the recommendations to be presented to the NSC into the following five topics as possible international activities: - Basic studies on behaviour of irradiated graphite/carbon and ceramic materials including their composites under both operation and storage conditions. - Development of in-core material characterisation and instrumentation methods. - Improvement in material properties through high-temperature irradiation. - Basic studies on HTGR fuel fabrication and performance including fission-product release. - Basic studies on safety issues of HTGR. It was also recommended that a further information exchange meeting focused on the organisation of the interactive collaboration activity with regard to the above topics be planned in 2003, tentatively in Oarai, Japan. (author)

  14. BRCA Testing by Single-Molecule Molecular Inversion Probes

    NARCIS (Netherlands)

    Neveling, K.; Mensenkamp, A.R.; Derks, R; Kwint, M.P.; Ouchene, H.; Steehouwer, M.; Lier, L.A. van; Bosgoed, E.A.J.; Rikken, A.; Tychon, M.W.J.; Zafeiropoulou, D.; Castelein, S.; Hehir-Kwa, J.Y.; Thung, G.W.; Hofste, T.; Lelieveld, S.H.; Bertens, S.M.; Adan, I.B.; Eijkelenboom, A.; Tops, B.B.J.; Yntema, H.G.; Stokowy, T.; Knappskog, P.M.; Hoberg-Vetti, H.; Steen, V.M.; Boyle, E.; Martin, B.; Ligtenberg, M.J.L.; Shendure, J.; Nelen, M.R.; Hoischen, A.

    2017-01-01

    BACKGROUND: Despite advances in next generation DNA sequencing (NGS), NGS-based single gene tests for diagnostic purposes require improvements in terms of completeness, quality, speed, and cost. Single-molecule molecular inversion probes (smMIPs) are a technology with unrealized potential in the

  15. Single-shell tank riser resistance to ground test plan

    International Nuclear Information System (INIS)

    Kiewert, L.R.

    1996-01-01

    This Test Procedure provides the general directions for conducting Single-Shell Tank Riser to Earth Measurements which will be used by engineering as a step towards providing closure for the Lightning Hazard Issue

  16. A single hole tracer test to determine longitudinal dispersion

    International Nuclear Information System (INIS)

    Noy, D.J.; Holmes, D.C.

    1986-03-01

    The paper concerns a single hole tracer test to determine longitudinal dispersion, which is an important parameter in assessing the suitability of a site for radioactive waste disposal. The theory, equipment and procedure for measuring longitudinal dispersion in a single borehole is described. Results are presented for field trials conducted in an aquifer, where the technique produced good results. The measured value of longitudinal dispersion, from a single hole test, relates only to a limited volume of rock immediately adjacent to the borehole. (U.K.)

  17. 49 CFR 232.305 - Single car air brake tests.

    Science.gov (United States)

    2010-10-01

    ... from a train or when placed on a shop or repair track, as defined in § 232.303(a); (2) A car is on a shop or repair track, as defined in § 232.303(a), for any reason and has not received a single car air... 49 Transportation 4 2010-10-01 2010-10-01 false Single car air brake tests. 232.305 Section 232...

  18. A single session of perturbation-based gait training with the A-TPAD improves dynamic stability in healthy young subjects.

    Science.gov (United States)

    Martelli, Dario; Kang, Jiyeon; Agrawal, Sunil K

    2017-07-01

    Gait and balance disorders are among the most common causes of falls in older adults. Most falls occur as a result of unexpected hazards while walking. In order to improve the effectiveness of current fall-prevention programs, new balance training paradigms aim to strengthen the control of the compensatory responses required after external perturbations. The aim of this study was to analyze the adaptions of reactive and proactive strategies to control stability after repeated exposures to waist-pull perturbations delivered while walking. Eight healthy young subjects participated in a single training session with the Active Tethered Pelvic assisted Device (A-TPAD). Participants were exposed to repeated multi-directional perturbations of increasing intensity. The Antero-Posterior (AP) and Medio-Lateral (ML) Base of Support (BoS) and Margin of Stability (MoS) during the response to diagonal perturbations were compared before and after the training. Results showed that participants adapted both the reactive and proactive strategies to control walking balance by significantly increasing their pre- and post-perturbation stability. The changes were principally accounted for by an increment of the AP BoS and MoS and a reduction of ML BoS. This improved their ability to react to a diagonal perturbation. We envision that this system can be used to develop a perturbation-based gait training aimed at improving balance and control of stability during walking, thus reducing fall risk.

  19. A case of effective single-session treatment for attention deficit and learning problems in a routine clinical practice: the value of a transdiagnostic approach to case formulation.

    Science.gov (United States)

    Whitefield-Alexander, Victoria; Edwards, David

    2009-06-01

    This article reports a systematic clinical case study of the psychological assessment and treatment of Daniel (9), a coloured South African boy with a diagnosis of attention deficit hyperactivity disorder (ADHD) (inattentive type). The case is of scientific interest because: (1) there was only a single treatment session, in which contingency management training was delivered to Daniel's parents and teacher; (2) there was evidence for the effectiveness of the intervention immediately and at two-year follow-up; (3) it documents the transportability to a South African context of an intervention developed by overseas research; (4) it documents the central role of case formulation in the delivery of effective psychological interventions; and (5) although Daniel met the criteria for ADHD, he also displayed symptoms of depression and social anxiety and the case supports the use of a transdiagnostic approach to case formulation. The conscientiousness with which his parents and teachers applied the programme was a major factor in the effectiveness of the intervention, and such rapid impact would not be possible where parents and teachers are unavailable or not co-operative. The publication of systematic case studies such as this one is important for the development of a local evidence-based practice in South Africa.

  20. Single session, intrauser repeatability of anterior chamber biometric and corneal pachy-volumetric parameters using a new Scheimpflug+Placido device.

    Science.gov (United States)

    Prakash, Gaurav; Srivastava, Dhruv

    2016-01-01

    To analyze single session, intrauser reliability of a Scheimpflug device for anterior chamber (AC) and corneal parameters. In this observational study, 100 normal candidates underwent Scheimpflug analysis with Sirius 3D Rotating Scheimpflug Camera and Topography System (Costruzione Strumenti Oftalmici, Italy). Two scans in dark room conditions were performed by the same experienced user. The candidates were asked to keep both eyes closed for 5min before the scans. Exclusion criteria were previous ocular surgery, corneal scarring and anterior segment/posterior segment anomalies. Only the right eyes were used for the analysis. Both corneal (central, minimum, and apical thickness, volume, horizontal visible iris diameter, and apical curvature) and anterior chamber (volume, depth, angle, horizontal diameter) measurements were evaluated. There was no difference in the means of repeated measurements (p>0.05, ANOVA). Intraclass correlations between the measures were high and ranged from 0.995-0.997 for corneal to 0.964-0.997 for anterior chamber (AC) parameters. The precision of repeatability measures (1.96×Sw) was approximately 5μ for the central and minimum corneal thickness, 8μ for the apical corneal thickness, 0.06mm for AC (anterior chamber) depth and less than 2° for the AC angle. Sirius Scheimpflug system has high repeatability for both corneal and AC parameters in normal eyes. Copyright © 2015 Spanish General Council of Optometry. Published by Elsevier Espana. All rights reserved.

  1. Hybrid Testing of Composite Structures with Single-Axis Control

    DEFF Research Database (Denmark)

    Waldbjørn, Jacob Paamand; Høgh, Jacob Herold; Stang, Henrik

    2013-01-01

    Hybrid testing is a substructuring technique where a structure is emulated by modelling a part of it in a numerical model while testing the remainder experimentally. Previous research in hybrid testing has been performed on multi-component structures e.g. damping fixtures, however in this paper...... a hybrid testing platform is introduced for single-component hybrid testing. In this case, the boundary between the numerical model and experimental setup is defined by multiple Degrees-Of-Freedoms (DOFs) which highly complicate the transferring of response between the two substructures. Digital Image...... Correlation (DIC) is therefore implemented for displacement control of the experimental setup. The hybrid testing setup was verified on a multicomponent structure consisting of a beam loaded in three point bending and a numerical structure of a frame. Furthermore, the stability of the hybrid testing loop...

  2. European accelerator facilities for single event effects testing

    Energy Technology Data Exchange (ETDEWEB)

    Adams, L.; Nickson, R.; Harboe-Sorensen, R. [ESA-ESTEC, Noordwijk (Netherlands); Hajdas, W.; Berger, G.

    1997-03-01

    Single event effects are an important hazard to spacecraft and payloads. The advances in component technology, with shrinking dimensions and increasing complexity will give even more importance to single event effects in the future. The ground test facilities are complex and expensive and the complexities of installing a facility are compounded by the requirement that maximum control is to be exercised by users largely unfamiliar with accelerator technology. The PIF and the HIF are the result of experience gained in the field of single event effects testing and represent a unique collaboration between space technology and accelerator experts. Both facilities form an essential part of the European infrastructure supporting space projects. (J.P.N.)

  3. Model tests on single piles in soft clay

    Energy Technology Data Exchange (ETDEWEB)

    Pan, J.L. [Durham Univ., Durham, (United Kingdom). School of Engineering; Goh, A.T.C.; Wong, K.S.; Teh, C.I. [Nanyang Technological Univ., (Singapore). Geotechnical Research Centre

    2000-08-04

    The behaviour of single stainless steel piles subjected to lateral soft clay soil movement was investigated in laboratory model tests in an effort to determine the ultimate soil pressure acting along the pile shaft. A custom designed apparatus was manufactured and calibrated for the test which measured the limiting soil pressures acting along the model pile shaft. The ultimate soil pressure was determined based on the maximum value of this measurement. The results show that the ultimate soil pressure for single passive piles was about 10 times the undrained shear strength, and the magnitude of the soil translation needed to fully mobilize the ultimate soil pressure on the single passive piles was about half the pile width. Further experimental study is needed to examine the effects of the pile end fixity, flexibility and shape and to confirm the effects of sample size and the disturbance due to soil sample preparation. 17 refs., 10 figs.

  4. Earthquake acceleration amplification based on single microtremor test

    Science.gov (United States)

    Jaya Syahbana, Arifan; Kurniawan, Rahmat; Soebowo, Eko

    2018-02-01

    Understanding soil dynamics is needed to understand soil behaviour, including the parameters of earthquake acceleration amplification. Many researchers now conduct single microtremor tests to obtain amplification of velocity and natural periods of soil at test sites. However, these amplification parameters are rarely used, so a method is needed to convert the velocity amplification to acceleration amplification. This paper will discuss the proposed process of changing the value of amplification. The proposed method is to integrate the time histories of the synthetic earthquake acceleration of the soil surface under the deaggregation at that location so the time histories of the velocity earthquake will be obtained. Next is to conduct a “fitting curve” between amplification by a single microtremor test with amplification of the synthetic earthquake velocity time histories. After obtaining the fitting curve time histories of velocity, differentiation will be conducted to obtain fitting curve acceleration time histories. The final step after obtaining the fitting curve is to compare the acceleration of the “fitting curve” against the histories time of the acceleration of synthetic earthquake at bedrocks to obtain single microtremor acceleration amplification factor.

  5. The effectiveness of neuro-music therapy according to the Heidelberg model compared to a single session of educational counseling as treatment for tinnitus: a controlled trial.

    Science.gov (United States)

    Argstatter, Heike; Grapp, Miriam; Hutter, Elisabeth; Plinkert, Peter K; Bolay, Hans-Volker

    2015-03-01

    Tinnitus is a very common symptom, yet the quest for an effective treatment is challenging. Results from several clinical trials support the notion that neuro-music therapy is an effective means to reduce tinnitus distress with short duration and long lasting effect. However, until now, the effectiveness has not been tested in a controlled trial against an active comparator. The trial was designed as two-center, parallel intervention group controlled study with two intervention groups: Counseling (50minute individualized personal instruction) or neuro-music therapy (counseling plus eight 50-minute sessions of individualized music therapy). Data of n=290 patients suffering from chronic tinnitus were analyzed. Outcome measure was the change in Tinnitus Questionnaire Total Scores (TQ) from baseline (admission) to end of treatment. Both treatment groups achieved a statistically relevant reduction in TQ scores, though 66% of patients in the music therapy group attained a clinically meaningful improvement compared to 33% in the counseling group. A binary logistic regression revealed two variables significantly influencing therapy outcome: initial tinnitus score and type of therapy with an OR for the music therapy compared to the counseling of 4.34 (CI 2.33-8.09). Counseling is an appropriate treatment option with well above chance of improvement. The neuro-music therapy outperformed the counseling. This treatment targets the tinnitus sound itself, is short in duration, intrinsically motivating and easy to operate and thus presents a possible complement to the therapeutic spectrum in chronic tinnitus. The trial was registered at the ClinicalTrials.gov registry (ID: NCT01845155). Copyright © 2014 Elsevier Inc. All rights reserved.

  6. Incremental Validity of Test Session and Classroom Observations in a Multimethod Assessment of Attention Deficit/Hyperactivity Disorder

    Science.gov (United States)

    McConaughy, Stephanie H.; Harder, Valerie S.; Antshel, Kevin M.; Gordon, Michael; Eiraldi, Ricardo; Dumenci, Levent

    2010-01-01

    This study tested the incremental validity of behavioral observations, over and above parent and teacher reports, for assessing symptoms of Attention Deficit/Hyperactivity Disorder (ADHD) in children ages 6 to 12, using the Test Observation Form (TOF) and Direct Observation Form (DOF) from the Achenbach System of Empirically Based Assessment. The…

  7. [Inter-session-processes].

    Science.gov (United States)

    Zeeck, Almut; Hartmann, Armin; Orlinsky, David

    2004-06-01

    We do not know much about how patients internalize, remember or use psychotherapeutic experiences between psychotherapy sessions and how they use them for change. What happens with in-session-experiences after a session ("inter-session-process") is of main importance for outcome. The inter-session-process describes the work on psychotherapy between sessions. Although inter-session-processes are a central element connecting psychotherapy process and outcome, they remain a neglected area of research. Previous studies examined individual outpatient settings only. This paper gives an overview over theory, instruments for measurement, previous studies and relevance of inter-session-processes for the field of psychotherapy research.

  8. Single specimen fracture toughness determination procedure using instrumented impact test

    International Nuclear Information System (INIS)

    Rintamaa, R.

    1993-04-01

    In the study a new single specimen test method and testing facility for evaluating dynamic fracture toughness has been developed. The method is based on the application of a new pendulum type instrumented impact tester equipped with and optical crack mouth opening displacement (COD) extensometer. The fracture toughness measurement technique uses the Double Displacement Ratio (DDR) method, which is based on the assumption that the specimen is deformed as two rigid arms that rotate around an apparent centre of rotation. This apparent moves as the crack grows, and the ratio of COD versus specimen displacement changes. As a consequence the onset ductile crack initiation can be detected on the load-displacement curve. Thus, an energy-based fracture toughness can be calculated. In addition the testing apparatus can use specimens with the Double ligament size as compared with the standard Charpy specimen which makes the impact testing more appropriate from the fracture mechanics point of view. The novel features of the testing facility and the feasibility of the new DDR method has been verified by performing an extensive experimental and analytical study. (99 refs., 91 figs., 27 tabs.)

  9. Evaluation of a single leg stance balance test in children.

    Science.gov (United States)

    Zumbrunn, Thomas; MacWilliams, Bruce A; Johnson, Barbara A

    2011-06-01

    Balance is a major determinate of gait. In high functioning individuals without significant vestibular or vision impairments, a ceiling effect may be present when using a double limb support protocol to assess balance function. For these populations, a single leg stance protocol may be more suitable. 47 typically developing (TD) subjects and 10 patients with CEV performed a single leg stance test on a force plate. The center of pressure (COP) was determined and several COP derived variables were calculated. Included measurements were: standard deviation, maximum excursion, area, average radial displacement, path velocity and frequency of the COP. Directional components of suitable variables were used to analyze anterior/posterior and medial/lateral contributions. Correlations with age of TD subjects indicated that all balance variables except frequency were significantly correlated. Most parameters were highly inter-correlated. Age adjusted COP balance variables also correlated to the Bruininks-Oseretsky balance subtest. Highest correlations were determined by the maximum excursion and velocity of the COP in the anterior/posterior direction. Statistical comparisons between the CEV group and a 4-6 TD group indicated significant differences between groups for most COP balance parameters. These results indicated that a single limb balance assessment may be a useful assessment for determining balance impairments in higher functioning children with orthopedic impairments. Copyright © 2011 Elsevier B.V. All rights reserved.

  10. Characterizing and modeling web sessions with applications

    OpenAIRE

    Chiarandini, Luca

    2014-01-01

    This thesis focuses on the analysis and modeling of web sessions, groups of requests made by a single user for a single navigation purpose. Understanding how people browse through websites is important, helping us to improve interfaces and provide to better content. After first conducting a statistical analysis of web sessions, we go on to present algorithms to summarize and model web sessions. Finally, we describe applications that use novel browsing methods, in particular parallel...

  11. Simple test system for single molecule recognition force microscopy

    International Nuclear Information System (INIS)

    Riener, Christian K.; Stroh, Cordula M.; Ebner, Andreas; Klampfl, Christian; Gall, Alex A.; Romanin, Christoph; Lyubchenko, Yuri L.; Hinterdorfer, Peter; Gruber, Hermann J.

    2003-01-01

    We have established an easy-to-use test system for detecting receptor-ligand interactions on the single molecule level using atomic force microscopy (AFM). For this, avidin-biotin, probably the best characterized receptor-ligand pair, was chosen. AFM sensors were prepared containing tethered biotin molecules at sufficiently low surface concentrations appropriate for single molecule studies. A biotin tether, consisting of a 6 nm poly(ethylene glycol) (PEG) chain and a functional succinimide group at the other end, was newly synthesized and covalently coupled to amine-functionalized AFM tips. In particular, PEG 800 diamine was glutarylated, the mono-adduct NH 2 -PEG-COOH was isolated by ion exchange chromatography and reacted with biotin succinimidylester to give biotin-PEG-COOH which was then activated as N-hydroxysuccinimide (NHS) ester to give the biotin-PEG-NHS conjugate which was coupled to the aminofunctionalized AFM tip. The motional freedom provided by PEG allows for free rotation of the biotin molecule on the AFM sensor and for specific binding to avidin which had been adsorbed to mica surfaces via electrostatic interactions. Specific avidin-biotin recognition events were discriminated from nonspecific tip-mica adhesion by their typical unbinding force (∼40 pN at 1.4 nN/s loading rate), unbinding length (<13 nm), the characteristic nonlinear force-distance relation of the PEG linker, and by specific block with excess of free d-biotin. The convenience of the test system allowed to evaluate, and compare, different methods and conditions of tip aminofunctionalization with respect to specific binding and nonspecific adhesion. It is concluded that this system is well suited as calibration or start-up kit for single molecule recognition force microscopy

  12. Successful single-session endosonography-based endoscopic retrograde cholangiopancreatography without fluoroscopy in pregnant patients with suspected choledocholithiasis: a case series.

    Science.gov (United States)

    Vohra, Sheba; Holt, Edward W; Bhat, Yasser M; Kane, Steve; Shah, Janak N; Binmoeller, Kenneth F

    2014-02-01

    Same session endosonography (EUS) immediately prior to scheduled endoscopic retrograde cholangiopancreatography (ERCP) may eliminate the need for ERCP and its associated risks in pregnant patients with no evidence of choledocholithiasis on EUS. In patients with choledocholithiasis, EUS provides information regarding the location, size and number of stones present, which helps guide biliary interventions and confirm stone clearance without the use of fluoroscopy. We retrospectively identified 10 pregnant patients referred to our tertiary endoscopy center for suspected choledocholithiasis between June 2008 and January 2012. All patients underwent same-session EUS-based ERCP. Of 10 pregnant patients managed with EUS-guided ERCP, six were found to have common bile duct stones and went on to ERCP. Four patients with no evidence of choledocholithiasis on EUS did not undergo ERCP. Patients with confirmed choledocholithiasis underwent ERCP without the use of fluoroscopy using the additional information provided by EUS. Same-session EUS immediately prior to scheduled ERCP may eliminate the need for ERCP and its risks in pregnant patients with no evidence of choledocholithiasis on EUS. In patients with confirmed choledocholithiasis, EUS provided additional information regarding the location, number and size of bile duct stones, which enabled the successful clearance of the bile duct without the use of fluoroscopy. © 2013 Japanese Society of Hepato-Biliary-Pancreatic Surgery.

  13. Single Stage Contactor Testing Of The Next Generation Solvent Blend

    Energy Technology Data Exchange (ETDEWEB)

    Herman, D. T.; Peters, T. B.; Duignan, M. R.; Williams, M. R.; Poirier, M. R.; Brass, E. A.; Garrison, A. G.; Ketusky, E. T.

    2014-01-06

    The Modular Caustic Side Solvent Extraction (CSSX) Unit (MCU) facility at the Savannah River Site (SRS) is actively pursuing the transition from the current BOBCalixC6 based solvent to the Next Generation Solvent (NGS)-MCU solvent to increase the cesium decontamination factor. To support this integration of NGS into the MCU facility the Savannah River National Laboratory (SRNL) performed testing of a blend of the NGS (MaxCalix based solvent) with the current solvent (BOBCalixC6 based solvent) for the removal of cesium (Cs) from the liquid salt waste stream. This testing utilized a blend of BOBCalixC6 based solvent and the NGS with the new extractant, MaxCalix, as well as a new suppressor, tris(3,7dimethyloctyl) guanidine. Single stage tests were conducted using the full size V-05 and V-10 liquid-to-liquid centrifugal contactors installed at SRNL. These tests were designed to determine the mass transfer and hydraulic characteristics with the NGS solvent blended with the projected heel of the BOBCalixC6 based solvent that will exist in MCU at time of transition. The test program evaluated the amount of organic carryover and the droplet size of the organic carryover phases using several analytical methods. The results indicate that hydraulically, the NGS solvent performed hydraulically similar to the current solvent which was expected. For the organic carryover 93% of the solvent is predicted to be recovered from the stripping operation and 96% from the extraction operation. As for the mass transfer, the NGS solvent significantly improved the cesium DF by at least an order of magnitude when extrapolating the One-stage results to actual Seven-stage extraction operation with a stage efficiency of 95%.

  14. Laboratory testing on infiltration in single synthetic fractures

    Science.gov (United States)

    Cherubini, Claudia; Pastore, Nicola; Li, Jiawei; Giasi, Concetta I.; Li, Ling

    2017-04-01

    An understanding of infiltration phenomena in unsaturated rock fractures is extremely important in many branches of engineering for numerous reasons. Sectors such as the oil, gas and water industries are regularly interacting with water seepage through rock fractures, yet the understanding of the mechanics and behaviour associated with this sort of flow is still incomplete. An apparatus has been set up to test infiltration in single synthetic fractures in both dry and wet conditions. To simulate the two fracture planes, concrete fractures have been moulded from 3D printed fractures with varying geometrical configurations, in order to analyse the influence of aperture and roughness on infiltration. Water flows through the single fractures by means of a hydraulic system composed by an upstream and a downstream reservoir, the latter being subdivided into five equal sections in order to measure the flow rate in each part to detect zones of preferential flow. The fractures have been set at various angles of inclination to investigate the effect of this parameter on infiltration dynamics. The results obtained identified that altering certain fracture parameters and conditions produces relevant effects on the infiltration process through the fractures. The main variables influencing the formation of preferential flow are: the inclination angle of the fracture, the saturation level of the fracture and the mismatch wavelength of the fracture.

  15. Testing the single degenerate channel for supernova Ia

    Science.gov (United States)

    Parsons, Steven

    2014-10-01

    The progenitors of supernova Ia are close binaries containing white dwarfs. Of crucial importance to the evolution of these systems is how much material the white dwarf can stably accrete and hence grow in mass. This occurs during a short-lived intense phase of mass transfer known as the super soft source (SSS) phase. The short duration of this phase and large extinction to soft X-rays means that only a handful are known in our Galaxy. Far more can be learned from the underlying SSS progenitor population of close white dwarf plus FGK type binaries. Unfortunately, these systems are hard to find since the main-sequence stars completely outshine the white dwarfs at optical wavelengths. Because of this, there are currently no known close white dwarf binaries with F, G or early K type companions, making it impossible to determine the contribution of the single degenerate channel towards supernova Ia. Using the GALEX and RAVE surveys we have now identified the first large sample of FGK stars with UV excesses, a fraction of which are these illusive, close systems. Following an intense ground based spectroscopic investigation of these systems, we have identified 5 definite close binaries, with periods of less than a few days. Here we apply for COS spectroscopic observations to measure the mass and temperature of the white dwarfs in order to determine the future evolution of these systems. This will provide a crucial test for the single degenerate channel towards supernova Ia.

  16. Crystal plasticity study of single crystal tungsten by indentation tests

    International Nuclear Information System (INIS)

    Yao, Weizhi

    2012-01-01

    Owing to its favorable material properties, tungsten (W) has been studied as a plasma-facing material in fusion reactors. Experiments on W heating in plasma sources and electron beam facilities have shown an intense micro-crack formation at the heated surface and sub-surface. The cracks go deep inside the irradiated sample, and often large distorted areas caused by local plastic deformation are present around the cracks. To interpret the crack-induced microscopic damage evolution process in W, one needs firstly to understand its plasticity on a single grain level, which is referred to as crystal plasticity. In this thesis, the crystal plasticity of single crystal tungsten (SCW) has been studied by spherical and Berkovich indentation tests and the finite element method with a crystal plasticity model. Appropriate values of the material parameters included in the crystal plasticity model are determined by fitting measured load-displacement curves and pile-up profiles with simulated counterparts for spherical indentation. The numerical simulations reveal excellent agreement with experiment. While the load-displacement curves and the deduced indentation hardness exhibit little sensitivity to the indented plane at small indentation depths, the orientation of slip directions within the crystals governs the development of deformation hillocks at the surface. It is found that several factors like friction, indentation depth, active slip systems, misoriented crystal orientation, misoriented sample surface and azimuthal orientation of the indenter can affect the indentation behavior of SCW. The Berkovich indentation test was also used to study the crystal plasticity of SCW after deuterium irradiation. The critical load (pop-in load) for triggering plastic deformation under the indenter is found to depend on the crystallographic orientation. The pop-in loads decrease dramatically after deuterium plasma irradiation for all three investigated crystallographic planes.

  17. Radiation tests for a single-GEM-loaded gaseous detector

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Kyong Sei; Hong, Byung Sik; Park, Sung Keun [Korea University, Seoul (Korea, Republic of); Kim, Sang Yeol [NoticeKorea, Anyang (Korea, Republic of)

    2014-11-15

    We report on a systematic study of a single-gas-electron-multiplier (GEM)-loaded gaseous detector developed for precision measurements of high-energy particle beams and for dose verification in particle therapy. In the present study, a 256-channel prototype detector having an active area of 16 x 16 cm{sup 2} and operating using a continuous current-integration-mode signal-processing method was manufactured and tested with X-rays emitted from a 70-kV X-ray generator and 43-MeV protons provided by the MC50 proton cyclotron at the Korea Institute of Radiological and Medical Science(KIRAMS). The amplified detector response was measured for X-rays with an intensity of about 5 x 10{sup 6} Hz cm{sup -2}. The linearity of the detector response to the particle flux was examined and validated by using 43-MeV proton beams. The non-uniform development of the amplification for the gas electrons in space was corrected by applying a proper calibration to the channel responses of the measured beam-profile data. We conclude from the radiation tests that the detector developed in the present study will allow us to perform quality measurements of various high-energy particle beams and to apply the technology to dose-verification measurements in particle therapy.

  18. Analysis of experiment testing technology for single event effects in China

    International Nuclear Information System (INIS)

    He Chaohui

    2001-01-01

    The merit and demerit of simulation source were analyzed for Single Event Effects (SEE) experiment testing in China. Laboratory experiment systems for SEE were brief introduced and requests for SEE test system were emphasize analyzed. Test systems were presented for Single Event Upset, Single Event Latch-up, Single Event Burnout and Single Event Gate-Rupture. The attention should be in mind in SEE experiments were discussed

  19. Columbia University flow instability experimental program: Volume 6. Single annulus tests, transient test program

    Energy Technology Data Exchange (ETDEWEB)

    Dougherty, T.; Maciuca, C.; McAssey, E.V. Jr.; Reddy, D.G.; Yang, B.W.

    1992-09-01

    The coolant in the Savannah River Site (SRS) production nuclear reactor assemblies is circulated as a subcooled liquid under normal operating conditions. This coolant is evenly distributed throughout multiple annular flow channels with a uniform pressure profile across each coolant flow channel. During the postulated Loss of Coolant Accident (LOCA), which is initiated by a hypothetical guillotine pipe break, the coolant flow through the reactor assemblies is significantly reduced. The flow reduction and accompanying power reduction (after shutdown is initiated) occur in the first 1 to 2 seconds of the LOCA. This portion of the LOCA is referred to as the Flow Instability phase. This report presents the experimental results for the transient portion of the single annulus test program. The test program was designed to investigate the onset of flow instability in an annular geometry similar to the MARK 22 reactor. The test program involved testing of both a ribless heater and a ribbed heater under steady state as well as transient conditions. The ribbed heater testing is currently underway and will be reported separately. The steady state portion of this test program with ribless heater was completed and reported in report No. CU-HTRF-T3A. The present report presents transient test results obtained from a ribless, uniform annulus test section. A total of thirty five transients were conducted with six cases in which flow excursion occurred. No unstable conditions resulted for tests in which the steady state Q{sub ratio} OFI limit was not exceeded.

  20. 49 CFR 232.307 - Modification of the single car air brake test procedures.

    Science.gov (United States)

    2010-10-01

    ... Requirements § 232.307 Modification of the single car air brake test procedures. (a) Request. The AAR or other authorized representative of the railroad industry may seek modification of the single car air brake test... 49 Transportation 4 2010-10-01 2010-10-01 false Modification of the single car air brake test...

  1. Both active and sham low-frequency rTMS single sessions over the right DLPFC decrease cue-induced cravings among pathological gamblers seeking treatment: A randomized, double-blind, sham-controlled crossover trial.

    Science.gov (United States)

    Sauvaget, Anne; Bulteau, Samuel; Guilleux, Alice; Leboucher, Juliette; Pichot, Anne; Valrivière, Pierre; Vanelle, Jean-Marie; Sébille-Rivain, Véronique; Grall-Bronnec, Marie

    2018-02-21

    Background Craving is a core symptom of addictive disorders, such as pathological gambling for example. Over the last decade, several studies have assessed the efficacy of repetitive transcranial magnetic stimulation (rTMS) in the addiction field, which triggers the dorsolateral prefrontal cortex (DLPFC) to decrease craving. The STIMJEU study investigated whether a single session of low-frequency (LF, i.e., 1 Hz) rTMS applied to the right DLPFC reduced cue-induced gambling craving in a sample of treatment-seeking pathological gamblers. Methods Thirty patients received both active and sham rTMS in random order and were blinded to the condition in a within-subject crossover design. Outcome measures included self-reported gambling craving (Visual Analog Scale and Gambling Craving Scale) and physiological measures (heart rate and blood pressure). Results The rTMS sessions were associated with a significant decrease in the gambling urge, regardless of whether the session was active or sham. When controlling cue-induced craving levels, no effects were observed on craving for active rTMS. Overall, rTMS was well-tolerated, and the credibility of the sham procedure was assessed and appeared to be appropriate. Conclusions We failed to demonstrate the specific efficacy of one session of LF rTMS to decrease cue-induced craving in pathological gamblers. A strong placebo-effect and rTMS parameters may partly explain these results. Yet, we are convinced that rTMS remains a promising therapeutic method. Further studies are required to examine its potential effect.

  2. Markers of biological stress in response to a single session of high-intensity interval training and high-volume training in young athletes.

    Science.gov (United States)

    Kilian, Yvonne; Engel, Florian; Wahl, Patrick; Achtzehn, Silvia; Sperlich, Billy; Mester, Joachim

    2016-12-01

    The aim of the present study was to compare the effects of high-intensity interval training (HIIT) vs high-volume training (HVT) on salivary stress markers [cortisol (sC), testosterone (sT), alpha-amylase (sAA)], metabolic and cardiorespiratory response in young athletes. Twelve young male cyclists (14 ± 1 years; 57.9 ± 9.4 mL min -1  kg -1 peak oxygen uptake) performed one session of HIIT (4 × 4 min intervals at 90-95 % peak power output separated by 3 min of active rest) and one session of HVT (90 min constant load at 60 % peak power output). The levels of sC, sT, their ratio (sT/sC) and sAA were determined before and 0, 30, 60, 180 min after each intervention. Metabolic and cardiorespiratory stress was characterized by blood lactate, blood pH, respiratory exchange ratio (RER) and heart rate (HR), oxygen uptake ([Formula: see text]), ventilation (V E ) and ventilatory equivalent (V E /[Formula: see text]). sC increased 30 and 60 min after HIIT. However, 180 min post exercise, sC decreased below baseline levels in both conditions. sT increased 0 and 30 min after HIIT and 0 min after HVT. sAA and sT/sC ratio did not change significantly over time in HIIT nor HVT. Metabolic and cardiorespiratory stress, evidenced by blood lactate, HR, [Formula: see text], V E , and V E /[Formula: see text] was higher during HIIT compared to HVT. The metabolic and cardiorespiratory stress during HIIT was higher compared to HVT, but based on salivary analyses (cortisol, testosterone, alpha-amylase), we conclude no strong acute catabolic effects neither by HIIT nor by HVT.

  3. Reliability testing of indirect composites as single implant restorations.

    Science.gov (United States)

    Suzuki, Marcelo; Bonfante, Estevam; Silva, Nelson Rfa; Coelho, Paulo G

    2011-10-01

    To investigate the reliability and failure modes of indirect composites as single-unit implant crowns. Thirty-eight custom-milled titanium alloy locking-taper abutments were divided into two groups (n = 19 each), and crown build-up of a mandibular molar was accomplished using two indirect composite systems (Ceramage, Shofu, Kyoto, Japan; Diamond Crown, DRM, Branford, CT). Three crowns of each material were loaded until failure for determination of the step-stress profiles. Reliability testing started at a load 30% of the mean load to failure and used three profiles with increasing fatigue loading (step stress). Weibull curves with 300 N stress and 90% confidence intervals were calculated and plotted using a power-law relationship. Weibull modulus "Beta" and characteristic strength "Eta" were identified, and a contour plot was used (Beta vs. Eta) for examining differences between groups. Specimens were inspected in polarized light and scanning electron microscope for fracture analysis. Use level Weibull probability showed fatigue being a damage factor only for the Ceramage group (β= 3.39) but not for the Diamond Crown group (β= 0.40). Overlap in the confidence bounds resulted in no statistical difference. Irrespective of composite system, fracture initiated in the region immediately below the contact between the indenter and the cusp, with the crack propagating toward the margins of cohesive failure. No significant differences were observed in life and Weibull probability calculations for Ceramage and Diamond Crown veneered onto Ti alloy abutments. Failure modes comprised composite veneer chippings. © 2011 by The American College of Prosthodontists.

  4. A persistent increase in insulin-stimulated glucose uptake by both fast-twitch and slow-twitch skeletal muscles after a single exercise session by old rats.

    Science.gov (United States)

    Xiao, Yuanyuan; Sharma, Naveen; Arias, Edward B; Castorena, Carlos M; Cartee, Gregory D

    2013-06-01

    Exercise has been demonstrated to enhance subsequent insulin-stimulated glucose uptake (GU) by predominantly type II (fast-twitch) muscle of old rats, but previous research has not evaluated exercise effects on GU by type I (slow-twitch) muscle from old rats. Accordingly, we studied male Fischer 344/Brown Norway rats (24 months old) and determined GU (0, 100, 200, and 5,000 μU/ml insulin) of isolated soleus (predominantly type I) and epitrochlearis (predominantly type II) muscles after one exercise session. Epitrochlearis (100, 200, and 5,000 μU/ml insulin) and soleus (100 and 200 μU/ml insulin) GU were greater at 3-h postexercise vs. age-matched sedentary controls. Insulin receptor tyrosine phosphorylation (Tyr1162/1163) was unaltered by exercise in either muscle. Akt phosphorylation (pAkt) was greater for exercised vs. sedentary rats in the epitrochlearis (Ser473 and Thr308 with 100 and 200 μU/ml, respectively) and soleus (Ser473 with 200 μU/ml). AS160 phosphorylation (pAS160) was greater for exercised vs. sedentary rats in the epitrochlearis (Thr642 with 100 μU/ml), but not the soleus. Exercised vs. sedentary rats did not differ for total protein abundance of insulin receptor, Akt, AS160, or GLUT4 in either muscle. These results demonstrate that both predominantly type I and type II muscles from old rats are susceptible to exercise-induced improvement in insulin-mediated GU by mechanisms that are independent of enhanced insulin receptor tyrosine phosphorylation or altered abundance of important signaling proteins or GLUT4. Exercise-induced elevation in pAkt, and possibly pAS160, may contribute to this effect in the epitrochlearis of old rats, but other mechanisms are likely important for the soleus.

  5. 49 CFR 232.309 - Equipment and devices used to perform single car air brake tests.

    Science.gov (United States)

    2010-10-01

    ... (Continued) FEDERAL RAILROAD ADMINISTRATION, DEPARTMENT OF TRANSPORTATION BRAKE SYSTEM SAFETY STANDARDS FOR... Testing Requirements § 232.309 Equipment and devices used to perform single car air brake tests. (a) Equipment and devices used to perform single car air brake tests shall be tested for correct operation at...

  6. Pulsed laser simulation of VLSI single-event effect testing study

    International Nuclear Information System (INIS)

    Xue Yuxiong; Cao Zhou Yang Shiyu; Tian Kai; Liu Shufen; Chu Nan; Cao Haining; Shang Zhi

    2008-01-01

    This paper describes a study aimed at investigating the pulsed laser simulation of Single-Event Effect (SEE) testing for VLSI Intel386EX CPU, using our laboratory LSS (laser simulation system). We have detailed SEE testing principle, testing method, testing system constituting, testing result. It validates that our laser pulses simulate may use SEE testing in VLSI, and Intel 386Ex have a large locking resistance to single event. (authors)

  7. Pre test parametric studies on single compartment vented enclosure

    International Nuclear Information System (INIS)

    Sharma, Pavan K.; Gera, B.; Singh, R.K.; Vaze, K.K.

    2011-01-01

    Establishing a proper design fire scenario is a challenging task and essential component for conducting fire safety design of buildings. A design fire scenario is a qualitative description of a fire with time identifying key events that characterize the fire (ignition, growth, flashover, fully-developed, and decay stages of fire). Proper fire safety design requires the appropriate selection of design fires against which the performance of the building is evaluated. The selection of the design fires directly impacts all aspects of fire safety performance, including the structural fire resistance, compartmentation against fire spread, egress systems, manual or automatic detection systems, suppression systems, and smoke control. The parameters affecting design fires include, the type, amount and arrangement of combustible materials, the ventilation conditions (air supply conditions, door/window open), and size of the compartment of fire origin. A design fire is a quantitative description of the characteristics of a fire, such as heat release rate (HRR), size of fire and its rate of spread, yield of products of combustion, and hot gas temperatures. Design fires are based on fire scenarios that replicate real fires. Six Computational Fluid Dynamics (CFD) numerical simulations were conducted in order to investigate the effect of fire load on fire dynamics in a) iso corner fire configuration b) IIT Delhi single compartment of a size of 5.0 m long, 5.0 m wide and 5.0 m high with doorway opening of 1m x 3m with centre fire of size 0.5 m x 0.5m. These types of simulation are carried out for deciding about the instrumentation scheme, safety aspect, and optimization of proposed experiments for National Fire Test Facility as pretest calculations. The simulations results are summarized in various identified applied parameter which are useful in terms of understanding the complex fire dynamics, validating the numerical tolls against experiments and using them (in form of values

  8. Single event effect testing of the Intel 80386 family and the 80486 microprocessor

    International Nuclear Information System (INIS)

    Moran, A.; LaBel, K.; Gates, M.; Seidleck, C.; McGraw, R.; Broida, M.; Firer, J.; Sprehn, S.

    1996-01-01

    The authors present single event effect test results for the Intel 80386 microprocessor, the 80387 coprocessor, the 82380 peripheral device, and on the 80486 microprocessor. Both single event upset and latchup conditions were monitored

  9. Session-RPE for quantifying the load of different youth basketball training sessions

    Directory of Open Access Journals (Sweden)

    C Lupo

    2016-12-01

    Full Text Available The aim of the study was to evaluate youth basketball training, verifying the reliability of the session-RPE method in relation to session duration (< and ≥ 80 minutes and workout typology (reduced and high warm-up, conditioning, technical, tactical, game portions within a single session categories. Six male youth basketball players (age, 16.5±0.5 years; height, 195.5±6.75 cm; body mass, 93.9±10.9 kg; and body mass index, 23.6±2.8 kg.m-2 were monitored (HR, type and duration of workouts during 15 (66 individual training sessions (80±26 minutes. Edwards’ HR method was used as a reference measure of internal training load (ITL; the CR-10 RPE scale was administered 30 minutes after the end of each session. The results obtained showed that all comparisons between different session durations and workout portions revealed effects in term of Edwards’ ITLs except for warm-up portions. Moderate to strong relationships between Edwards’ and session- RPE methods emerged for all sessions (r = .85, P < .001, player’s sessions (r range = .79 - .95, P < .001, session durations (< 80 minutes: r = .67, P < .001; ≥ 80 minutes: r = .75, P < .001, and workout portions (r range = .78 - .89, P range = .002 - < .001. The findings indicated that coaches of youth basketball players can successfully use session-RPE to monitor the ITL, regardless of session durations and workout portions.

  10. Numerical test for single concrete armour layer on breakwaters

    OpenAIRE

    Anastasaki, E; Latham, J-P; Xiang, J

    2016-01-01

    The ability of concrete armour units for breakwaters to interlock and form an integral single layer is important for withstanding severe wave conditions. In reality, displacements take place under wave loading, whether they are small and insignificant or large and representing serious structural damage. In this work, a code that combines finite- and discrete-element methods which can simulate motion and interaction among units was used to conduct a numerical investigation. Various concrete ar...

  11. Fabrication and test of Superconducting Single Photon Detectors

    International Nuclear Information System (INIS)

    Leoni, R.; Mattioli, F.; Castellano, M.G.; Cibella, S.; Carelli, P.; Pagano, S.; Perez de Lara, D.; Ejrnaes, M.; Lisitskyi, M.P.; Esposito, E.; Cristiano, R.; Nappi, C.

    2006-01-01

    We report here on the state of our fabrication process for Superconducting Single Photon Detectors (SSPDs). We have fabricated submicrometer SSPD structures by electron beam lithography using very thin (10 nm) NbN films deposited by DC-magnetron sputtering on different substrates and at room substrate temperature. The structures show a fast optical response (risetime <500 ps limited by readout electronics) and interesting self-resetting features

  12. Complications after liver transplantation: evaluation with magnetic resonance imaging, magnetic resonance cholangiography, and 3-dimensional contrast-enhanced magnetic resonance angiography in a single session

    International Nuclear Information System (INIS)

    Boraschi, P.; Donati, F.; Gigoni, R.; Salemi, S.; Urbani, L.; Filipponi, F.; Falaschi, F.; Bartolozzi, C.

    2008-01-01

    To evaluate a comprehensive magnetic resonance imaging (MRI) protocol as noninvasive diagnostic modality for simultaneous detection of parenchymal, biliary, and vascular complications after liver transplantation. Fifty-two liver transplant recipients suspected to have parenchymal, biliary, and (or) vascular complications underwent our MRI protocol at 1.5T unit using a phased array coil. After preliminary acquisition of axial T 1 w and T 2 w sequences, magnetic resonance cholangiography (MRC) was performed through a breath-hold, thin- and thick-slab, single-shot T 2 w sequence in the coronal plane. Contrast-enhanced magnetic resonance angiography (CEMRA) was obtained using a 3-dimensional coronal spoiled gradient-echo sequence, which enabled acquisition of 32 partitions 2.0 mm thick. A fixed dose of 20 ml gadobenate dimeglumine was administered at 2 mL/s. A post-contrast T 1 w sequence was also performed. Two observers in conference reviewed source images and 3-dimensional reconstructions to determine the presence of parenchymal, biliary, and vascular complications. MRI findings were correlated with surgery, endoscopic retrograde cholangiography (ERC), biopsy, digital subtraction angiography (DSA), and imaging follow-up. MRI revealed abnormal findings in 32 out of 52 patients (61%), including biliary complications (anastomotic and nonanastomotic strictures, and lithiasis) in 31, vascular disease (hepatic artery stenosis and thrombosis) in 9, and evidence of hepatic abscess and hematoma in 2. ERC confirmed findings of MRC in 30 cases, but suggested disease underestimation in 2. DSA confirmed 7 magnetic resonance angiogram (MRA) findings, but suggested disease overestimation in 2. MRI combined with MRC and CEMRA can provide a comprehensive assessment of parenchymal, biliary, and vascular complications in most recipients of liver transplantation. (author)

  13. Complications after liver transplantation: evaluation with magnetic resonance imaging, magnetic resonance cholangiography, and 3-dimensional contrast-enhanced magnetic resonance angiography in a single session

    Energy Technology Data Exchange (ETDEWEB)

    Boraschi, P.; Donati, F.; Gigoni, R. [Pisa Univ. Hospital, Second Dept. of Radiology, Pisa (Italy)], E-mail: p.boraschi@do.med.unipi.it; Salemi, S. [Univ. of Pisa, Diagnostic and Interventional Radiology, Pisa (Italy); Urbani, L.; Filipponi, F. [Univ. of Pisa, Liver Transplant Unit of the Dept. of Oncology, Transplants and Advanced Technologies in Medicine, Pisa (Italy); Falaschi, F. [Pisa Univ. Hospital, Second Dept. of Radiology, Pisa (Italy); Bartolozzi, C. [Univ. of Pisa, Diagnostic and Interventional Radiology, Pisa (Italy)

    2008-12-15

    To evaluate a comprehensive magnetic resonance imaging (MRI) protocol as noninvasive diagnostic modality for simultaneous detection of parenchymal, biliary, and vascular complications after liver transplantation. Fifty-two liver transplant recipients suspected to have parenchymal, biliary, and (or) vascular complications underwent our MRI protocol at 1.5T unit using a phased array coil. After preliminary acquisition of axial T{sub 1}w and T{sub 2}w sequences, magnetic resonance cholangiography (MRC) was performed through a breath-hold, thin- and thick-slab, single-shot T{sub 2}w sequence in the coronal plane. Contrast-enhanced magnetic resonance angiography (CEMRA) was obtained using a 3-dimensional coronal spoiled gradient-echo sequence, which enabled acquisition of 32 partitions 2.0 mm thick. A fixed dose of 20 ml gadobenate dimeglumine was administered at 2 mL/s. A post-contrast T{sub 1}w sequence was also performed. Two observers in conference reviewed source images and 3-dimensional reconstructions to determine the presence of parenchymal, biliary, and vascular complications. MRI findings were correlated with surgery, endoscopic retrograde cholangiography (ERC), biopsy, digital subtraction angiography (DSA), and imaging follow-up. MRI revealed abnormal findings in 32 out of 52 patients (61%), including biliary complications (anastomotic and nonanastomotic strictures, and lithiasis) in 31, vascular disease (hepatic artery stenosis and thrombosis) in 9, and evidence of hepatic abscess and hematoma in 2. ERC confirmed findings of MRC in 30 cases, but suggested disease underestimation in 2. DSA confirmed 7 magnetic resonance angiogram (MRA) findings, but suggested disease overestimation in 2. MRI combined with MRC and CEMRA can provide a comprehensive assessment of parenchymal, biliary, and vascular complications in most recipients of liver transplantation. (author)

  14. Effect of different single-session educational modalities on improving medical students' ability to demonstrate proper pressurized metered dose inhaler technique.

    Science.gov (United States)

    Dominelli, Giulio S; Dominelli, Paolo B; Rathgeber, Steven L; Webster, Sheila B

    2012-05-01

    Pressurized metered dose inhalers (pMDIs) remain important therapeutic options for obstructive lung diseases. The ability to instruct and evaluate inhaler technique is a crucial skill that all medical professionals should possess; unfortunately, many professionals lack proficiency with pMDIs. We aimed to determine if brief education interventions of differing modalities can positively affect medical students' skills over the long term. The baseline ability of medical students and first year residents to use pMDIs was scored via a 10-point scoring system. Students were randomized to receive no education, one-on-one instruction, or video instruction. Students were then retested immediately after the education and at the 3-month mark for retention of acquired skills. Video, one-on-one and the placebo groups modalities statistically improved the average medical student's score in the immediate retesting (7.5 and 7.4 vs. 4.7, p grades at the immediate recall significantly improved for both modalities. During retention testing, only video education had a statistically significant improvement in pass rate over the control group, as defined by an average score of 7 or better (8 vs. 1, p improve medical students' ability to use pMDIs in short-term testing. However, only video education retained significant improvement compared with control after 3 months. This suggests that compared with traditional one-on-one teaching, video education is an effective means of teaching medical students how to improve their pMDI technique.

  15. Application of modern tests for stationarity to single-trial MEG data: transferring powerful statistical tools from econometrics to neuroscience.

    Science.gov (United States)

    Kipiński, Lech; König, Reinhard; Sielużycki, Cezary; Kordecki, Wojciech

    2011-10-01

    Stationarity is a crucial yet rarely questioned assumption in the analysis of time series of magneto- (MEG) or electroencephalography (EEG). One key drawback of the commonly used tests for stationarity of encephalographic time series is the fact that conclusions on stationarity are only indirectly inferred either from the Gaussianity (e.g. the Shapiro-Wilk test or Kolmogorov-Smirnov test) or the randomness of the time series and the absence of trend using very simple time-series models (e.g. the sign and trend tests by Bendat and Piersol). We present a novel approach to the analysis of the stationarity of MEG and EEG time series by applying modern statistical methods which were specifically developed in econometrics to verify the hypothesis that a time series is stationary. We report our findings of the application of three different tests of stationarity--the Kwiatkowski-Phillips-Schmidt-Schin (KPSS) test for trend or mean stationarity, the Phillips-Perron (PP) test for the presence of a unit root and the White test for homoscedasticity--on an illustrative set of MEG data. For five stimulation sessions, we found already for short epochs of duration of 250 and 500 ms that, although the majority of the studied epochs of single MEG trials were usually mean-stationary (KPSS test and PP test), they were classified as nonstationary due to their heteroscedasticity (White test). We also observed that the presence of external auditory stimulation did not significantly affect the findings regarding the stationarity of the data. We conclude that the combination of these tests allows a refined analysis of the stationarity of MEG and EEG time series.

  16. Psycho-social counselling in predictive genetic testing for cancer: the association between number of supportive sessions and client characteristics as assessed by psycho-social workers

    NARCIS (Netherlands)

    Mollema, E. D.; Smets, E. M. A.; Richard, M. E.; Schiphorst, A. M.; Leschot, N. J.

    2008-01-01

    Given the increased demand on genetic services, it is important to identify clients who may require relatively more extensive psychosocial support. This paper describes which client characteristics, as assessed in the first psycho-social counselling session, were associated with requiring relatively

  17. Testing single point incremental forming molds for thermoforming operations

    Science.gov (United States)

    Afonso, Daniel; de Sousa, Ricardo Alves; Torcato, Ricardo

    2016-10-01

    Low pressure polymer processing processes as thermoforming or rotational molding use much simpler molds then high pressure processes like injection. However, despite the low forces involved with the process, molds manufacturing for this operations is still a very material, energy and time consuming operation. The goal of the research is to develop and validate a method for manufacturing plastically formed sheets metal molds by single point incremental forming (SPIF) operation for thermoforming operation. Stewart platform based SPIF machines allow the forming of thick metal sheets, granting the required structural stiffness for the mold surface, and keeping the short lead time manufacture and low thermal inertia.

  18. Evaluating Upper-Body Strength and Power From a Single Test: The Ballistic Push-up.

    Science.gov (United States)

    Wang, Ran; Hoffman, Jay R; Sadres, Eliahu; Bartolomei, Sandro; Muddle, Tyler W D; Fukuda, David H; Stout, Jeffrey R

    2017-05-01

    Wang, R, Hoffman, JR, Sadres, E, Bartolomei, S, Muddle, TWD, Fukuda, DH, and Stout, JR. Evaluating upper-body strength and power from a single test: the ballistic push-up. J Strength Cond Res 31(5): 1338-1345, 2017-The purpose of this study was to examine the reliability of the ballistic push-up (BPU) exercise and to develop a prediction model for both maximal strength (1 repetition maximum [1RM]) in the bench press exercise and upper-body power. Sixty recreationally active men completed a 1RM bench press and 2 BPU assessments in 3 separate testing sessions. Peak and mean force, peak and mean rate of force development, net impulse, peak velocity, flight time, and peak and mean power were determined. Intraclass correlation coefficients were used to examine the reliability of the BPU. Stepwise linear regression was used to develop 1RM bench press and power prediction equations. Intraclass correlation coefficient's ranged from 0.849 to 0.971 for the BPU measurements. Multiple regression analysis provided the following 1RM bench press prediction equation: 1RM = 0.31 × Mean Force - 1.64 × Body Mass + 0.70 (R = 0.837, standard error of the estimate [SEE] = 11 kg); time-based power prediction equation: Peak Power = 11.0 × Body Mass + 2012.3 × Flight Time - 338.0 (R = 0.658, SEE = 150 W), Mean Power = 6.7 × Body Mass + 1004.4 × Flight Time - 224.6 (R = 0.664, SEE = 82 W); and velocity-based power prediction equation: Peak Power = 8.1 × Body Mass + 818.6 × Peak Velocity - 762.0 (R = 0.797, SEE = 115 W); Mean Power = 5.2 × Body Mass + 435.9 × Peak Velocity - 467.7 (R = 0.838, SEE = 57 W). The BPU is a reliable test for both upper-body strength and power. Results indicate that the mean force generated from the BPU can be used to predict 1RM bench press, whereas peak velocity and flight time measured during the BPU can be used to predict upper-body power. These findings support the potential use of the BPU as a valid method to evaluate upper-body strength and power.

  19. Testing for one Generalized Linear Single Order Parameter

    DEFF Research Database (Denmark)

    Ellegaard, Niels Langager; Christensen, Tage Emil; Dyre, Jeppe

    work the order parameter may be chosen to have a non-exponential relaxation. The model predictions contradict the general consensus of the properties of viscous liquids in two ways: (i) The model predicts that following a linear isobaric temperature step, the normalized volume and entalpy relaxation......We examine a linear single order parameter model for thermoviscoelastic relaxation in viscous liquids, allowing for a distribution of relaxation times. In this model the relaxation of volume and entalpy is completely described by the relaxation of one internal order parameter. In contrast to prior...... functions are identical. This assumption conflicts with some (but not all) reports, utilizing the Tool-Narayanaswamy formalism to extrapolate from non-linear measurements to the linear regime. (ii) The model predicts that the theoretical "linear Prigogine-Defay" ratio is one. This ratio has never been...

  20. Post-Session Authentication

    DEFF Research Database (Denmark)

    Ahmed, Naveed; Jensen, Christian D.

    2012-01-01

    Entity authentication provides confidence in the claimed identity of a peer entity, but the manner in which this goal is achieved results in different types of authentication. An important factor in this regard is the order between authentication and the execution of the associated session. In th...... as the only setup assumption. We hope post-session authentication can be used to devise new strategies for building trust among strangers....

  1. Detectability of single and plural flaws by ultrasonic testing

    International Nuclear Information System (INIS)

    Iida, K.

    1985-01-01

    An outline and up-to-date test results of an eight year project of proving tests on the effectiveness of in-service inspection is described in the first part of the present paper. Effects on the detectability of such testing parameters as refraction angle, thickness of stainless steel cladding, inspectors, standard flaws in reference specimens, stress state subjected to defects are discussed. This is followed by a discussion of detection reproducibility, resolution and accuracy of inspected size of a defects. The latter part of the paper deals with up-to-date results of tests on resolution and shape determination of propagating adjacent and co-linear fatigue cracks by ultrasonic examination. It was found that real lengths of fatigue crack and EDM surface notch will be roughly estimated by 12 dB and 8 dB down methods, respectively. It is also concluded that the 10 dB down method is available for estimation of the inside distance of two co-linear surface cracks

  2. Dynamic tensile test of single PET textile cables

    Directory of Open Access Journals (Sweden)

    Pasco F.

    2012-08-01

    Full Text Available The tyres conception involves for certain applications, the use of textile cables as reinforcement. During its use, the tyre undergoes temperatures variations and dynamic loading rates. The consideration of these conditions during the numeric simulations requires the knowledge of the sensitivity of the mechanical behaviour to loading rate and temperature. In this paper, we developed an experimental methodology for testing textile cable up to high strain rate. The main difficulty of testing cables is the optimization of cable fixing on the machine. For that purpose, we adapted the solution of fixing by progressive binding already used in quasi-static, while taking into account constraints inherent to high strain tests. Firstly, the mass of grips was decreased in order to get force signal less sensitive to grips inertia. The method was developed on a high speed hydraulic machine equipped with a thermal enclosure. The investigated temperatures and strain rates range from room temperature to 373 ∘K (100 ∘C and from 0,01 to 100/s, respectively. In addition, the hydraulic machine was equipped with a high speed video camera. The obtained images were analysed by a tracking technique to measure the average strain in the cable (from 50 to 20000 f/s.

  3. Injection molded nanofluidic chips: Fabrication method and functional tests using single-molecule DNA experiments

    DEFF Research Database (Denmark)

    Utko, Pawel; Persson, Karl Fredrik; Kristensen, Anders

    2011-01-01

    We demonstrate that fabrication of nanofluidic systems can be greatly simplified by injection molding of polymers. We functionally test our devices by single-molecule DNA experiments in nanochannels.......We demonstrate that fabrication of nanofluidic systems can be greatly simplified by injection molding of polymers. We functionally test our devices by single-molecule DNA experiments in nanochannels....

  4. 76 FR 34801 - Petition for Modification of Single Car Air Brake Test Procedures

    Science.gov (United States)

    2011-06-14

    ... reference in 49 CFR 232.305) is intended for freight cars with automatic brake systems that are...] Petition for Modification of Single Car Air Brake Test Procedures In accordance with Part 232 of Title 49... Railroad Administration (FRA) grant a modification of the single car air brake test procedures as...

  5. Summary: Hadron dynamics sessions

    International Nuclear Information System (INIS)

    Carroll, A.S.; Londergan, J.T.

    1993-01-01

    Four sessions on Hadron Dynamics were organized at this Workshop. The first topic, QCD Exclusive Reactions and Color Transparency, featured talks by Ralston, Heppelman and Strikman; the second, QCD and Inclusive Reactions had talks by Garvey, Speth and Kisslinger. The third dynamics session, Medium Modification of Elementary Interactions had contributions from Kopeliovich, Alves and Gyulassy; the fourth session Pre-QCD Dynamics and Scattering, had talks by Harris, Myhrer and Brown. An additional joint Spectroscopy/Dynamics session featured talks by Zumbro, Johnson and McClelland. These contributions are reviewed briefly in this summary. Two additional joint sessions between Dynamics and η physics are reviewed by the organizers of the Eta sessions. In such a brief review there is no way the authors can adequately summarize the details of the physics presented here. As a result, they concentrate only on brief impressionistic sketches of the physics topics discussed and their interrelations. They include no bibliography in this summary, but simply refer to the talks given in more detail in the Workshop proceedings. They focus on topics which were common to several presentations in these sessions. First, nuclear and particle descriptions of phenomena are now clearly converging, in both a qualitative and quantitative sense; they show several examples of this convergence. Second, an important issue in hadron dynamics is the extent to which elementary interactions are modified in nuclei at high energies and/or densities, and they illustrate some of these medium effects. Finally, they focus on those dynamical issues where hadron facilities can make an important, or even a unique, contribution to the knowledge of particle and nuclear physics

  6. Summary: Hadron dynamics sessions

    Energy Technology Data Exchange (ETDEWEB)

    Carroll, A.S. [Brookhaven National Lab., Upton, NY (United States); Londergan, J.T. [Indiana Univ., Bloomington, IN (United States)

    1993-11-01

    Four sessions on Hadron Dynamics were organized at this Workshop. The first topic, QCD Exclusive Reactions and Color Transparency, featured talks by Ralston, Heppelman and Strikman; the second, QCD and Inclusive Reactions had talks by Garvey, Speth and Kisslinger. The third dynamics session, Medium Modification of Elementary Interactions had contributions from Kopeliovich, Alves and Gyulassy; the fourth session Pre-QCD Dynamics and Scattering, had talks by Harris, Myhrer and Brown. An additional joint Spectroscopy/Dynamics session featured talks by Zumbro, Johnson and McClelland. These contributions are reviewed briefly in this summary. Two additional joint sessions between Dynamics and {eta} physics are reviewed by the organizers of the Eta sessions. In such a brief review there is no way the authors can adequately summarize the details of the physics presented here. As a result, they concentrate only on brief impressionistic sketches of the physics topics discussed and their interrelations. They include no bibliography in this summary, but simply refer to the talks given in more detail in the Workshop proceedings. They focus on topics which were common to several presentations in these sessions. First, nuclear and particle descriptions of phenomena are now clearly converging, in both a qualitative and quantitative sense; they show several examples of this convergence. Second, an important issue in hadron dynamics is the extent to which elementary interactions are modified in nuclei at high energies and/or densities, and they illustrate some of these medium effects. Finally, they focus on those dynamical issues where hadron facilities can make an important, or even a unique, contribution to the knowledge of particle and nuclear physics.

  7. LHC BLM Single Channel Connectivity Test using the Standard Installation

    CERN Document Server

    Emery, J; Effinger, E; Ferioli, G; Zamantzas, C; Ikeda, H; Verhagen, E

    2009-01-01

    For the LHC Beam Loss Measurement system (BLM), the high voltage supply of the ionisation chambers and the secondary emission detectors is used to test their connectivity. A harmonic modulation of 0.03 Hz results in a current signal of about 100pA measured by the beam loss acquisition electronics. The signal is analyzed and the measured amplitude and phase are compared with individual channel limits for the 4000 channels. It is foreseen to execute an automatic procedure for all channels every 12 hours which takes about 20 minutes. The paper will present the design of the system, the circuit simulations, measurements of systematic dependencies of different channels and the reproducibility of the amplitude and phase measurements.

  8. Test procedures and instructions for single shell tank saltcake cesium removal with crystalline silicotitanate

    Energy Technology Data Exchange (ETDEWEB)

    Duncan, J.B.

    1997-01-07

    This document provides specific test procedures and instructions to implement the test plan for the preparation and conduct of a cesium removal test, using Hanford Single Shell Tank Saltcake from tanks 24 t -BY- I 10, 24 1 -U- 108, 24 1 -U- 109, 24 1 -A- I 0 1, and 24 t - S-102, in a bench-scale column. The cesium sorbent to be tested is crystalline siticotitanate. The test plan for which this provides instructions is WHC-SD-RE-TP-024, Hanford Single Shell Tank Saltcake Cesium Removal Test Plan.

  9. NEPP Update of Independent Single Event Upset Field Programmable Gate Array Testing

    Science.gov (United States)

    Berg, Melanie; Label, Kenneth; Campola, Michael; Pellish, Jonathan

    2017-01-01

    This presentation provides a NASA Electronic Parts and Packaging (NEPP) Program update of independent Single Event Upset (SEU) Field Programmable Gate Array (FPGA) testing including FPGA test guidelines, Microsemi RTG4 heavy-ion results, Xilinx Kintex-UltraScale heavy-ion results, Xilinx UltraScale+ single event effect (SEE) test plans, development of a new methodology for characterizing SEU system response, and NEPP involvement with FPGA security and trust.

  10. Session 2: Machine studies

    International Nuclear Information System (INIS)

    Assmann, R.W.; Papotti, G.

    2012-01-01

    This document summarizes the talks and discussion that took place in the second session of the Chamonix 2012 workshop concerning results from machine studies performed in 2011. The session consisted of the following presentations: -) LHC experience with different bunch spacings by G. Rumolo; -) Observations of beam-beam effects in MDs in 2011 by W. Herr; -) Beam-induced heating/ bunch length/RF and lessons for 2012 by E. Metral; -) Lessons in beam diagnostics by R. Jones; -) Quench margins by M. Sapinski; and -) First demonstration with beam of the Achromatic Telescopic Squeeze (ATS) by S. Fartoukh. (authors)

  11. The effects of isolated single umbilical artery on first and second trimester aneuploidy screening test parameters.

    Science.gov (United States)

    Tulek, Firat; Kahraman, Alper; Taskin, Salih; Ozkavukcu, Esra; Soylemez, Feride

    2015-04-01

    Reliability of first and second trimester screening tests largely depends on accurate estimation of maternal serum marker values. Reduced reliability could lead redundant invasive tests or misdiagnosis. Adjustments of serum marker values for confounding factors like insulin-dependent diabetes, maternal weight or maternal rhesus status are essential. We aimed to investigate whether isolated single umbilical artery alters first and second trimester test parameters or not. Routine detailed obstetric ultrasonographies performed were retrospectively screened for this study. Among spontaneously conceived singleton pregnancies, women who were found to have single umbilical artery without any additional structural anomalies or aneuploidies were selected. First and second trimester screening test results were accessible for 98 and 102 of the cases with isolated single umbilical artery, respectively. Among first trimester screening test parameters, PAPP-A (pregnancy-associated plasma protein A) MoMs were found significantly higher in isolated single umbilical artery group. AFP MoMs were found significantly elevated in isolated single umbilical artery group in second trimester quadruple tests. Existence of single umbilical artery could alter the estimation of MoM values of maternal serum markers. Reliability of prenatal screening tests could be improved by adjusting these parameters in accordance with isolated single umbilical artery.

  12. Evaluation procedures for single axis sinusoidal test to design spectrum requirements

    International Nuclear Information System (INIS)

    Sun, P.C.; Javid, A.

    1983-01-01

    Two simple procedures are provided in this paper for the purpose of evaluating the adequacy of a single frequency single axis test. For the purpose of evaluating the adequacy of single frequency test to meet broad-band response spectrum requirements, the proposed procedure is based on the equivalence of maximum response of a dynamic system when it is subjected to either type of design input. The required information used for the evaluation is usually recorded and available in the test report. This procedure is applicable to systems with or without closely-spaced modes. When evaluating against broad-band design spectra and multi-axes requirements, an empirical procedure is proposed and it has been found conservative. These two proposed procedures provide a quick assessment on the adequacy of a single frequency test performed earlier. The use of these procedures may eliminate the need of expensive and time consuming equipment re-testing. (orig./HP)

  13. Summary of Session III

    International Nuclear Information System (INIS)

    Furman, M.A.

    2002-01-01

    This is a summary of the talks presented in Session III ''Simulations of Electron-Cloud Build Up'' of the Mini-Workshop on Electron-Cloud Simulations for Proton and Positron Beams ECLOUD-02, held at CERN, 15-18 April 2002

  14. Session 7: Reserve

    International Nuclear Information System (INIS)

    Bailey, R.; Crockford, G.

    2001-01-01

    The reserve session was devoted to some issues that came up through the workshop, which were grouped into three main areas: The Global Accelerator Network, Problems of stress and how to get organized to minimize them, What should an operations group be responsible for? This paper summarizes the discussions that took place. (author)

  15. Multiparty Asynchronous Session Types

    DEFF Research Database (Denmark)

    Honda, Kohei; Yoshida, Nobuko; Carbone, Marco

    2016-01-01

    Communication is a central elements in software development. As a potential typed foundation for structured communication-centered programming, session types have been studied over the past decade for a wide range of process calculi and programming languages, focusing on binary (two-party) sessio...

  16. Poster Session- Extended Abstracts

    Science.gov (United States)

    Jack D. Alexander III; Jean Findley; Brenda K. Kury; Jan L. Beyers; Douglas S. Cram; Terrell T. Baker; Jon C. Boren; Carl Edminster; Sue A. Ferguson; Steven McKay; David Nagel; Trent Piepho; Miriam Rorig; Casey Anderson; Jeanne Hoadley; Paulette L. Ford; Mark C. Andersen; Ed L. Fredrickson; Joe Truett; Gary W. Roemer; Brenda K. Kury; Jennifer Vollmer; Christine L. May; Danny C. Lee; James P. Menakis; Robert E. Keane; Zhi-Liang Zhu; Carol Miller; Brett Davis; Katharine Gray; Ken Mix; William P. Kuvlesky Jr.; D. Lynn Drawe; Marcia G. Narog; Roger D. Ottmar; Robert E. Vihnanek; Clinton S. Wright; Timothy E. Paysen; Burton K. Pendleton; Rosemary L. Pendleton; Carleton S. White; John Rogan; Doug Stow; Janet Franklin; Jennifer Miller; Lisa Levien; Chris Fischer; Emma Underwood; Robert Klinger; Peggy Moore; Clinton S. Wright

    2008-01-01

    Titles found within Poster Session-Extended Abstracts include:Assessment of emergency fire rehabilitation of four fires from the 2000 fire season on the Vale, Oregon, BLM district: review of the density sampling materials and methods: p. 329 Growth of regreen, seeded for erosion control, in the...

  17. The outreach sessions

    Energy Technology Data Exchange (ETDEWEB)

    Trache, Livius [Horia Hulubei National Institute for Physics and Nuclear Engineering, P.O. Box MG-6, 077125 Bucharest-Magurele (Romania)

    2015-02-24

    These are moderator’s remarks about the outreach day in the middle of the CSSP14, and in particular about the afternoon outreach session in round table format with the announced theme: “CERN at 60 and the internationalization of science”.

  18. Results of single borehole hydraulic testing in the Mizunami Underground Research Laboratory project. Phase 2

    International Nuclear Information System (INIS)

    Daimaru, Shuji; Takeuchi, Ryuji; Onoe, Hironori; Saegusa, Hiromitsu

    2012-09-01

    This report summarize the results of the single borehole hydraulic tests of 79 sections conducted as part of the Construction phase (Phase 2) in the Mizunami Underground Research Laboratory (MIU) Project. The details of each test (test interval depth, geology, etc.) as well as the interpreted hydraulic parameters and analytical method used are presented in this report. (author)

  19. NASA Electronic Parts and Packaging Field Programmable Gate Array Single Event Effects Test Guideline Update

    Science.gov (United States)

    Berg, Melanie D.; LaBel, Kenneth A.

    2018-01-01

    The following are updated or new subjects added to the FPGA SEE Test Guidelines manual: academic versus mission specific device evaluation, single event latch-up (SEL) test and analysis, SEE response visibility enhancement during radiation testing, mitigation evaluation (embedded and user-implemented), unreliable design and its affects to SEE Data, testing flushable architectures versus non-flushable architectures, intellectual property core (IP Core) test and evaluation (addresses embedded and user-inserted), heavy-ion energy and linear energy transfer (LET) selection, proton versus heavy-ion testing, fault injection, mean fluence to failure analysis, and mission specific system-level single event upset (SEU) response prediction. Most sections within the guidelines manual provide information regarding best practices for test structure and test system development. The scope of this manual addresses academic versus mission specific device evaluation and visibility enhancement in IP Core testing.

  20. Forecast of thermal-hydrological conditions and air injection test results of the single heater test at Yucca Mountain

    International Nuclear Information System (INIS)

    Birkholzer, J.T.; Tsang, Y.W.

    1996-12-01

    The heater in the Single Heater Test (SHT) in alcove 5 of the Exploratory Studies Facility (ESF) was turned on August 26, 1996. A large number of sensors are installed in the various instrumented boreholes to monitor the coupled thermal-hydrological-mechanical-chemical responses of the rock mass to the heat generated in the single heater. In this report the authors present the results of the modeling of both the heating and cooling phases of the Single Heater Test (SHT), with focus on the thermal-hydrological aspect of the coupled processes. Also in this report, the authors present simulations of air injection tests will be performed at different stages of the heating and cooling phase of the SHT

  1. Intersection tests for single marker QTL analysis can be more powerful than two marker QTL analysis

    Directory of Open Access Journals (Sweden)

    Doerge RW

    2003-06-01

    Full Text Available Abstract Background It has been reported in the quantitative trait locus (QTL literature that when testing for QTL location and effect, the statistical power supporting methodologies based on two markers and their estimated genetic map is higher than for the genetic map independent methodologies known as single marker analyses. Close examination of these reports reveals that the two marker approaches are more powerful than single marker analyses only in certain cases. Simulation studies are a commonly used tool to determine the behavior of test statistics under known conditions. We conducted a simulation study to assess the general behavior of an intersection test and a two marker test under a variety of conditions. The study was designed to reveal whether two marker tests are always more powerful than intersection tests, or whether there are cases when an intersection test may outperform the two marker approach. We present a reanalysis of a data set from a QTL study of ovariole number in Drosophila melanogaster. Results Our simulation study results show that there are situations where the single marker intersection test equals or outperforms the two marker test. The intersection test and the two marker test identify overlapping regions in the reanalysis of the Drosophila melanogaster data. The region identified is consistent with a regression based interval mapping analysis. Conclusion We find that the intersection test is appropriate for analysis of QTL data. This approach has the advantage of simplicity and for certain situations supplies equivalent or more powerful results than a comparable two marker test.

  2. Understanding the effect of single-fracture heterogeneity from single-well injection-withdrawal (SWIW) tests

    Science.gov (United States)

    Larsson, Martin; Doughty, Christine; Tsang, Chin-Fu; Niemi, Auli

    2013-12-01

    The single-well injection-withdrawal (SWIW) tracer test is a method used to estimate the tracer retardation properties of a fracture or fracture zone. The effects of single-fracture aperture heterogeneity on SWIW-test tracer breakthrough curves are examined by numerical modelling. The effects of the matrix diffusion and sorption are accounted for by using a particle tracking method through the addition of a time delay added to the advective transport time. For a given diffusion and sorption property ( P m) value and for a heterogeneous fracture, the peak concentration is larger compared to a homogeneous fracture. The cumulative breakthrough curve for a heterogeneous fracture is similar to that for a homogeneous fracture and a less sorptive/diffusive tracer. It is demonstrated that the fracture area that meets the flowing water, the specific flow-wetted surface (sFWS) of the fracture, can be determined by matching the observed breakthrough curve for a heterogeneous fracture to that for a homogeneous fracture with an equivalent property parameter. SWIW tests are also simulated with a regional pressure gradient present. The results point to the possibility of distinguishing the effect of the regional pressure gradient from that of diffusion through the use of multiple tracers with different P m values.

  3. The Influence of Age on Interaction between Breath-Holding Test and Single-Breath Carbon Dioxide Test

    Directory of Open Access Journals (Sweden)

    Nikita Trembach

    2017-01-01

    Full Text Available Introduction. The aim of the study was to compare the breath-holding test and single-breath carbon dioxide test in evaluation of the peripheral chemoreflex sensitivity to carbon dioxide in healthy subjects of different age. Methods. The study involved 47 healthy volunteers between ages of 25 and 85 years. All participants were divided into 4 groups according to age: 25 to 44 years (n=14, 45 to 60 years (n=13, 60 to 75 years (n=12, and older than 75 years (n=8. Breath-holding test was performed in the morning before breakfast. The single-breath carbon dioxide (SB-CO2 test was performed the following day. Results. No correlation was found between age and duration of breath-holding (r=0.13 and between age and peripheral chemoreflex sensitivity to CO2 (r=0.07. In all age groups there were no significant differences in the mean values from the breath-holding test and peripheral chemoreflex sensitivity tests. In all groups there was a strong significant inverse correlation between breath-holding test and SB-CO2 test. Conclusion. A breath-holding test reflects the sensitivity of the peripheral chemoreflex to carbon dioxide in healthy elderly humans. Increasing age alone does not alter the peripheral ventilatory response to hypercapnia.

  4. The Influence of Age on Interaction between Breath-Holding Test and Single-Breath Carbon Dioxide Test.

    Science.gov (United States)

    Trembach, Nikita; Zabolotskikh, Igor

    2017-01-01

    Introduction . The aim of the study was to compare the breath-holding test and single-breath carbon dioxide test in evaluation of the peripheral chemoreflex sensitivity to carbon dioxide in healthy subjects of different age. Methods . The study involved 47 healthy volunteers between ages of 25 and 85 years. All participants were divided into 4 groups according to age: 25 to 44 years ( n = 14), 45 to 60 years ( n = 13), 60 to 75 years ( n = 12), and older than 75 years ( n = 8). Breath-holding test was performed in the morning before breakfast. The single-breath carbon dioxide (SB-CO 2 ) test was performed the following day. Results . No correlation was found between age and duration of breath-holding ( r = 0.13) and between age and peripheral chemoreflex sensitivity to CO 2 ( r = 0.07). In all age groups there were no significant differences in the mean values from the breath-holding test and peripheral chemoreflex sensitivity tests. In all groups there was a strong significant inverse correlation between breath-holding test and SB-CO 2 test. Conclusion . A breath-holding test reflects the sensitivity of the peripheral chemoreflex to carbon dioxide in healthy elderly humans. Increasing age alone does not alter the peripheral ventilatory response to hypercapnia.

  5. Analytical solutions for efficient interpretation of single-well push-pull tracer tests

    Science.gov (United States)

    Single-well push-pull tracer tests have been used to characterize the extent, fate, and transport of subsurface contamination. Analytical solutions provide one alternative for interpreting test results. In this work, an exact analytical solution to two-dimensional equations descr...

  6. Fibre reinforced concrete in flexure and single fibre pull-out test: a correlation

    Science.gov (United States)

    Manca, M.; Ciancio, D.; Dight, P.

    2017-09-01

    The aim of the present work is to assess whether a single fibre pull-out test can be related to the behaviour of multiple fibres in fibre reinforced concrete under bending condition. A simple model based on the stress block theory is described and compared with experimental results on three point bending tests with aligned fibres.

  7. Content Coverage of Single-Word Tests Used to Assess Common Phonological Error Patterns

    Science.gov (United States)

    Kirk, Cecilia; Vigeland, Laura

    2015-01-01

    Purpose: This review evaluated whether 9 single-word tests of phonological error patterns provide adequate content coverage to accurately identify error patterns that are active in a child's speech. Method: Tests in the current study were considered to display sufficient opportunities to assess common phonological error patterns if they…

  8. A single standard for in-place testing of DOE HEPA filters - not

    Energy Technology Data Exchange (ETDEWEB)

    Mokler, B.V. [Los Alamos National Laboratory, NM (United States)

    1995-02-01

    This article is a review of arguments against the use of a single standard for in-place testing of DOE HEPA filters. The author feels that the term `standard` entails mandatory compliance. Additionally, the author feels that the variety of DOE HEPA systems requiring in-place testing is such that the guidance for testing must be written in a permissive fashion, allowing options and alternatives. With this in mind, it is not possible to write a single document entailing mandatory compliance for all DOE facilities.

  9. A single standard for in-place testing of DOE HEPA filters - not

    International Nuclear Information System (INIS)

    Mokler, B.V.

    1995-01-01

    This article is a review of arguments against the use of a single standard for in-place testing of DOE HEPA filters. The author feels that the term 'standard' entails mandatory compliance. Additionally, the author feels that the variety of DOE HEPA systems requiring in-place testing is such that the guidance for testing must be written in a permissive fashion, allowing options and alternatives. With this in mind, it is not possible to write a single document entailing mandatory compliance for all DOE facilities

  10. Comparison of retrograde intrarenal surgery versus a single-session percutaneous nephrolithotomy for lower-pole stones with a diameter of 15 to 30 mm: A propensity score-matching study.

    Science.gov (United States)

    Jung, Gyoo Hwan; Jung, Jae Hyun; Ahn, Tae Sik; Lee, Joong Sub; Cho, Sung Yong; Jeong, Chang Wook; Lee, Seung Bae; Kim, Hyeon Hoe; Oh, Seung-June

    2015-07-01

    To investigate surgical outcomes between retrograde intrarenal surgery (RIRS) and percutaneous nephrolithotomy (PNL) groups for a main stone sized 15 to 30 mm and located in the lower-pole calyx. Patients who underwent PNL or RIRS for a main stone sized 15 to 30 mm and located in the lower-pole calyx were retrospectively reviewed. Each patient in the RIRS group was matched to one in the PNL group on the basis of calculated propensity scores by use of age, sex, body mass index, previous treatment history, stone site, maximum stone size, and stone volume. We compared perioperative outcomes between the unmatched and matched groups. Patients underwent PNL (n=87, 66.4%) or RIRS (n=44, 33.6%). After matching, 44 patients in each group were included. Mean patient age was 54.4 ± 13.7 years. Perioperative hemoglobin drop was significantly higher and the hospital stay was longer in the PNL group than in the RIRS group. The operative time was significantly longer in the RIRS group than in the PNL group. Stone-free rates were higher and complications rates were lower in the RIRS group than in the PNL group without statistical significance. The presence of a stone located in the lower-anterior minor calyx was a predictor of stone-free status. RIRS and single-session PNL for patients with a main stone of 15 to 30 mm located in the lower-pole calyx showed comparable surgical results. However, RIRS can be performed more safely than PNL with less bleeding. Stones in the lower-anterior minor calyx should be carefully removed during these procedures.

  11. ICALEPS 2005 : opening session

    CERN Multimedia

    Maximilien Brice

    2005-01-01

    ICALEPCS 2005, the tenth International Conference on Accelerator and Large Experimental Physics Control Systems, will be held in Geneva, Switzerland, 10-14 Oct. 2005 at the International Conference Center Geneva (CICG). ICALEPCS 2005 thus falls in the year that UNESCO has declared the "World Year of Physics". ICALEPCS covers all aspects of control and operation of Experimental Physics facilities such as particle accelerators, particle detectors, optical telescopes, radio telescopes, nuclear fusion facilities like Tokamaks, nuclear reactors, lasers, etc .... Opening session by . A. Daneels (CERN): Introducting ICALEPCS 2005 . C.Lamprecht (Republic & State of Geneva): Welcome speech . J. Lister (EPFL): Welcome speech . J. Engelen (CERN): The machine and experiment challenges of LHC

  12. Session: Hard Rock Penetration

    Energy Technology Data Exchange (ETDEWEB)

    Tennyson, George P. Jr.; Dunn, James C.; Drumheller, Douglas S.; Glowka, David A.; Lysne, Peter

    1992-01-01

    This session at the Geothermal Energy Program Review X: Geothermal Energy and the Utility Market consisted of five presentations: ''Hard Rock Penetration - Summary'' by George P. Tennyson, Jr.; ''Overview - Hard Rock Penetration'' by James C. Dunn; ''An Overview of Acoustic Telemetry'' by Douglas S. Drumheller; ''Lost Circulation Technology Development Status'' by David A. Glowka; ''Downhole Memory-Logging Tools'' by Peter Lysne.

  13. Session: Reservoir Technology

    Energy Technology Data Exchange (ETDEWEB)

    Renner, Joel L.; Bodvarsson, Gudmundur S.; Wannamaker, Philip E.; Horne, Roland N.; Shook, G. Michael

    1992-01-01

    This session at the Geothermal Energy Program Review X: Geothermal Energy and the Utility Market consisted of five papers: ''Reservoir Technology'' by Joel L. Renner; ''LBL Research on the Geysers: Conceptual Models, Simulation and Monitoring Studies'' by Gudmundur S. Bodvarsson; ''Geothermal Geophysical Research in Electrical Methods at UURI'' by Philip E. Wannamaker; ''Optimizing Reinjection Strategy at Palinpinon, Philippines Based on Chloride Data'' by Roland N. Horne; ''TETRAD Reservoir Simulation'' by G. Michael Shook

  14. Basic life support knowledge, self-reported skills and fears in Danish high school students and effect of a single 45-min training session run by junior doctors; a prospective cohort study

    DEFF Research Database (Denmark)

    Aaberg, Anne Marie Roust; Larsen, Caroline Emilie Brenner; Rasmussen, Bodil Steen

    2014-01-01

    training session run by junior doctors. METHODS: Six-hundred-fifty-one students were included. They underwent one 45-minute BLS training session including theoretical aspects and hands-on training with mannequins. The students completed a baseline questionnaire before the training session and a follow......-three percent of the students (413/651) had participated in prior BLS training. Only 28% (179/651) knew how to correctly recognize normal breathing. The majority was afraid of exacerbating the condition or causing death by intervening as first responder. The response rate at follow-up was 61% (399...... areas of BLS is poor among high school students. One hands-on training session run by junior doctors seems to be efficient to empower the students to be first responders to OHCA....

  15. Test-retest reliability of single and paired pulse transcranial magnetic stimulation parameters in healthy subjects.

    Science.gov (United States)

    Hermsen, A M; Haag, A; Duddek, C; Balkenhol, K; Bugiel, H; Bauer, S; Mylius, V; Menzler, K; Rosenow, F

    2016-03-15

    To determine the influence of different factors on test-retest reliability of frequently used transcranial magnetic stimulation (TMS) parameters while controlling for potential confounders in healthy subjects. TMS was applied in 93 healthy volunteers (61% male) twice (mean retest interval of 34.0 ± 25.6 (SD) days) between 7 am and 2 pm by four investigators (sessions n investigator A=47, investigator B=95, investigator C=28, investigator D=16). Women were assessed in their follicular phase. Test stimulus (TS), resting motor threshold (RMT), short latency intracortical inhibition (SICI), intracortical facilitation (ICF) and cortical silent period (SCP) were analyzed. Good test-retest reliabilities were observed for TS (r=.880) and RMT (r=.826), moderate for visual and automated analyzed CSP durations (resp. r=.466, r=.486), and poor for ICF (r=-.159). Reliable change indexes are reported. Gender (e.g. automated CSP women: r=.538 vs. men: r=.422), re-test interval and method of CSP-analysis did not influence reliabilities. In a large sample of healthy volunteers we found good to moderate test-retest reliabilities in all but one TMS-parameter. Automated analysis of the CSP did not prove to be more reliable than visual determination. This study contains analyses of re-test reliability in TMS considering several confounding factors. For the first time it presents reliable change indices for all frequently used TMS parameters. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. Reliability Assessment of a Single-Shot System by Use of Screen Test Results

    Science.gov (United States)

    2018-02-01

    unlimited. NUWC Keyport #17-002. Reliability Assessment of a Single-Shot System by Use of Screen Test Results Abstract: Field reliability prediction...approach described here assumes that the defect density during testing takes the form of an exponential decay, although other mathematical functions can...be substituted for the exponential. In order to apply the decay rate function to a discrete pass/fail test scheme, the approach provides for

  17. 98th LHCC meeting Agenda OPEN Session and CLOSED Session

    CERN Document Server

    CERN. Geneva

    2009-01-01

    OPEN Session on Wednesday, 8 July at 9h00-11h00 in Main Auditorium, Live webcast, followed by CLOSED Session, Conference room 160-1-009 11h20-17h00. CLOSED Session continued on Thursday, 9 July at 9h00-12h30

  18. Radon Testing for Safe Schools Act. Report (To Accompany S. 1697) from the Committee on Environment and Public Works, United States Senate, One Hundred First Congress, Second Session.

    Science.gov (United States)

    Congress of the U.S., Washington, DC. Senate Committee on Environment and Public Works.

    This report was written to accompany the Radon Testing for Safe Schools Act (S.1697), a bill that provides for radon testing of schools located in high risk radon areas and provides limited financial assistance to schools for mitigation of high levels of radon. A description of radon, its harmful effects, and the radon levels detected in schools…

  19. The Influence of Age on Interaction between Breath-Holding Test and Single-Breath Carbon Dioxide Test

    OpenAIRE

    Trembach, Nikita; Zabolotskikh, Igor

    2017-01-01

    Introduction. The aim of the study was to compare the breath-holding test and single-breath carbon dioxide test in evaluation of the peripheral chemoreflex sensitivity to carbon dioxide in healthy subjects of different age. Methods. The study involved 47 healthy volunteers between ages of 25 and 85 years. All participants were divided into 4 groups according to age: 25 to 44 years (n = 14), 45 to 60 years (n = 13), 60 to 75 years (n = 12), and older than 75 years (n = 8). Breath-holding test ...

  20. Homogeneity tests for variances and mean test under heterogeneity conditions in a single way ANOVA method

    International Nuclear Information System (INIS)

    Morales P, J.R.; Avila P, P.

    1996-01-01

    If we have consider the maximum permissible levels showed for the case of oysters, it results forbidding to collect oysters at the four stations of the El Chijol Channel ( Veracruz, Mexico), as well as along the channel itself, because the metal concentrations studied exceed these limits. In this case the application of Welch tests were not necessary. For the water hyacinth the means of the treatments were unequal in Fe, Cu, Ni, and Zn. This case is more illustrative, for the conclusion has been reached through the application of the Welch tests to treatments with heterogeneous variances. (Author)

  1. Single Event Effects Test Facility Options at the Oak Ridge National Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Riemer, Bernie [ORNL; Gallmeier, Franz X [ORNL; Dominik, Laura J [ORNL

    2015-01-01

    Increasing use of microelectronics of ever diminishing feature size in avionics systems has led to a growing Single Event Effects (SEE) susceptibility arising from the highly ionizing interactions of cosmic rays and solar particles. Single event effects caused by atmospheric radiation have been recognized in recent years as a design issue for avionics equipment and systems. To ensure a system meets all its safety and reliability requirements, SEE induced upsets and potential system failures need to be considered, including testing of the components and systems in a neutron beam. Testing of integrated circuits (ICs) and systems for use in radiation environments requires the utilization of highly advanced laboratory facilities that can run evaluations on microcircuits for the effects of radiation. This paper provides a background of the atmospheric radiation phenomenon and the resulting single event effects, including single event upset (SEU) and latch up conditions. A study investigating requirements for future single event effect irradiation test facilities and developing options at the Spallation Neutron Source (SNS) is summarized. The relatively new SNS with its 1.0 GeV proton beam, typical operation of 5000 h per year, expertise in spallation neutron sources, user program infrastructure, and decades of useful life ahead is well suited for hosting a world-class SEE test facility in North America. Emphasis was put on testing of large avionics systems while still providing tunable high flux irradiation conditions for component tests. Makers of ground-based systems would also be served well by these facilities. Three options are described; the most capable, flexible, and highest-test-capacity option is a new stand-alone target station using about one kW of proton beam power on a gas-cooled tungsten target, with dual test enclosures. Less expensive options are also described.

  2. Ambiguity in measuring matrix diffusion with single-well injection/recovery tracer tests

    Science.gov (United States)

    Lessoff, S.C.; Konikow, Leonard F.

    1997-01-01

    Single-well injection/recovery tracer tests are considered for use in characterizing and quantifying matrix diffusion in dual-porosity aquifers. Numerical modeling indicates that neither regional drift in homogeneous aquifers, nor heterogeneity in aquifers having no regional drift, nor hydrodynamic dispersion significantly affects these tests. However, when drift is coupled simultaneously with heterogeneity, they can have significant confounding effects on tracer return. This synergistic effect of drift and heterogeneity may help explain irreversible flow and inconsistent results sometimes encountered in previous single-well injection/recovery tracer tests. Numerical results indicate that in a hypothetical single-well injection/recovery tracer test designed to demonstrate and measure dual-porosity characteristics in a fractured dolomite, the simultaneous effects of drift and heterogeneity sometimes yields responses similar to those anticipated in a homogeneous dual-porosity formation. In these cases, tracer recovery could provide a false indication of the occurrence of matrix diffusion. Shortening the shut-in period between injection and recovery periods may make the test less sensitive to drift. Using multiple tracers having different diffusion characteristics, multiple tests having different pumping schedules, and testing the formation at more than one location would decrease the ambiguity in the interpretation of test data.

  3. Comparative Performance of Four Single Extreme Outlier Discordancy Tests from Monte Carlo Simulations

    Directory of Open Access Journals (Sweden)

    Surendra P. Verma

    2014-01-01

    Full Text Available Using highly precise and accurate Monte Carlo simulations of 20,000,000 replications and 102 independent simulation experiments with extremely low simulation errors and total uncertainties, we evaluated the performance of four single outlier discordancy tests (Grubbs test N2, Dixon test N8, skewness test N14, and kurtosis test N15 for normal samples of sizes 5 to 20. Statistical contaminations of a single observation resulting from parameters called δ from ±0.1 up to ±20 for modeling the slippage of central tendency or ε from ±1.1 up to ±200 for slippage of dispersion, as well as no contamination (δ=0 and ε=±1, were simulated. Because of the use of precise and accurate random and normally distributed simulated data, very large replications, and a large number of independent experiments, this paper presents a novel approach for precise and accurate estimations of power functions of four popular discordancy tests and, therefore, should not be considered as a simple simulation exercise unrelated to probability and statistics. From both criteria of the Power of Test proposed by Hayes and Kinsella and the Test Performance Criterion of Barnett and Lewis, Dixon test N8 performs less well than the other three tests. The overall performance of these four tests could be summarized as N2≅N15>N14>N8.

  4. Testing of the large bore single aperture 1-meter superconducting dipoles made with phenolic inserts

    CERN Document Server

    Boschmann, H; Dubbeldam, R L; Kirby, G A; Lucas, J; Ostojic, R; Russenschuck, Stephan; Siemko, A; Taylor, T M; Vanenkov, I; Weterings, W

    1998-01-01

    Two identical single aperture 1-metre superconducting dipoles have been built in collaboration with HMA Power Systems and tested at CERN. The 87.8 mm aperture magnets feature a single layer coil wound using LHC main dipole outer layer cable, phenolic spacer type collars, and a keyed two part structural iron yoke. The magnets are designed as models of the D1 separation dipole in the LHC experimental insertions, whose nominal field is 4.5 T at 4.5 K. In this report we present the test results of the two magnets at 4.3 K and 1.9 K.

  5. Crash tests of three identical low-wing single-engine airplane

    Science.gov (United States)

    Castle, C. B.; Alfaro-Bou, E.

    1983-01-01

    Three identical four place, low wing single engine airplane specimens with nominal masses of 1043 kg were crash tested under controlled free flight conditions. The tests were conducted at the same nominal velocity of 25 m/sec along the flight path. Two airplanes were crashed on a concrete surface (at 10 and 30 deg pitch angles), and one was crashed on soil (at a -30 deg pitch angle). The three tests revealed that the specimen in the -30 deg test on soil sustained massive structural damage in the engine compartment and fire wall. Also, the highest longitudinal cabin floor accelerations occurred in this test. Severe damage, but of lesser magnitude, occurred in the -30 deg test on concrete. The highest normal cabin floor accelerations occurred in this test. The least structural damage and lowest accelerations occurred in the 10 deg test on concrete.

  6. TR-PIV Performance Test for a Flow Field Measurement in a Single Rod Test Section

    Energy Technology Data Exchange (ETDEWEB)

    Park, Ju Yong; Shin, Chang Hwan; Lee, Chi Young; Oh, Dong Seok; In, Wang Kee [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2011-10-15

    For large enhancement of performance of Pressurized Water Reactor(PWR), dual-cooled fuel is being developed in Korea Atomic Energy Research Institute(KAERI). This nuclear fuel is a ring shape fuel which is different from conventional cylindrical nuclear fuel and cooling water flows both inner and outer channel. For this fuel, it widens the surface area. But it is bigger outer diameter of fuel rods. So, interval between fuel rods narrows. This because of outer channel flow is unstable. So, measurement of turbulence flow and perturbation that influence in heat transfer elevation is important.. To understand heat transfer characteristics by turbulence, measurement of flow perturbation element is necessary. To measure these turbulence characteristics, hot wire anemometer is widely used. However, it has many disadvantages such as low durability of prove, and big probe size. For these reasons, TR-PIV(Time-Resolved Particle Image Velocimetry) system is employed for better flow measurement in our research institute. TR-PIV system is consisted of laser system and high-speed camera that have high frequency. So, was judged that can measurement complicated turbulence flow and perturbation. In this paper, introduce TR-PIV system, and with results acquiring in single rod flow through this system, and wish to introduce about after this practical use plan

  7. TR-PIV Performance Test for a Flow Field Measurement in a Single Rod Test Section

    International Nuclear Information System (INIS)

    Park, Ju Yong; Shin, Chang Hwan; Lee, Chi Young; Oh, Dong Seok; In, Wang Kee

    2011-01-01

    For large enhancement of performance of Pressurized Water Reactor(PWR), dual-cooled fuel is being developed in Korea Atomic Energy Research Institute(KAERI). This nuclear fuel is a ring shape fuel which is different from conventional cylindrical nuclear fuel and cooling water flows both inner and outer channel. For this fuel, it widens the surface area. But it is bigger outer diameter of fuel rods. So, interval between fuel rods narrows. This because of outer channel flow is unstable. So, measurement of turbulence flow and perturbation that influence in heat transfer elevation is important.. To understand heat transfer characteristics by turbulence, measurement of flow perturbation element is necessary. To measure these turbulence characteristics, hot wire anemometer is widely used. However, it has many disadvantages such as low durability of prove, and big probe size. For these reasons, TR-PIV(Time-Resolved Particle Image Velocimetry) system is employed for better flow measurement in our research institute. TR-PIV system is consisted of laser system and high-speed camera that have high frequency. So, was judged that can measurement complicated turbulence flow and perturbation. In this paper, introduce TR-PIV system, and with results acquiring in single rod flow through this system, and wish to introduce about after this practical use plan

  8. Validation of the dual-table autoradiographic method to quantify two sequential rCBFs in a single SPET session with N-isopropyl-[123I]p-iodoamphetamine

    International Nuclear Information System (INIS)

    Nishizawa, Sadahiko; Iida, Hidehiro; Tsuchida, Tatsuro; Ito, Harumi; Konishi, Junji; Yonekura, Yoshiharu

    2003-01-01

    We evaluated an autoradiographic (ARG) method to calculate regional cerebral blood flow (rCBF) sequentially before and after an acetazolamide (ACZ) challenge in a single session of single-photon emission tomography (SPET) with two injections of N-isopropyl-[ 123 I]p-iodoamphetamine (IMP). The method uses a table look-up method with a fixed distribution volume (Vd) and a standard input function of IMP. To calculate rCBF after an ACZ challenge, two look-up tables (a dual-table) are used to reflect the effect of radioactivity in the brain from the first dose of IMP. We performed simulation studies to evaluate errors attributable to (a) a change in rCBF induced by an ACZ challenge during the scan and (b) a fixed Vd value that might be different from an individual one, along with the effect of (c) scan length. Thirty-three patients were studied by dynamic SPET with two injections of IMP and frequent arterial blood sampling, and the data were analysed using the dual-table ARG method. Twenty-four of the 33 patients received an injection of ACZ 10 min before the second dose of IMP. We generated a standard input function by averaging individual input functions. The optimal method to calibrate a standard input function was determined so that the SD of differences between rCBF calculated by using a calibrated standard input function (F SIF ) and that calculated by using an individual input function (F IIF ) was minimised. Reliability of the method was evaluated by comparing F SIF with gold standard rCBF (F REF ) obtained by two-compartment model analysis of dynamic SPET data and an individual input function with a non-linear least squares fitting method. Errors caused by (a) were less than 4% for a first rCBF ranging between 20 and 60 ml 100 g -1 min -1 and an rCBF change of between -25% and 50%. Errors caused by (b) were relatively large compared with those caused by (a), and were affected by (c) with an increasing error in a longer scan. In the patient study with a proposed

  9. Working session 1: Tubing degradation

    International Nuclear Information System (INIS)

    Kharshafdjian, G.; Turluer, G.

    1997-01-01

    A general introductory overview of the purpose of the group and the general subject area of SG tubing degradation was given by the facilitator. The purpose of the session was described as to open-quotes develop conclusions and proposals on regulatory and technical needs required to deal with the issues of SG tubing degradation.close quotes Types, locations and characteristics of tubing degradation in steam generators were briefly reviewed. The well-known synergistic effects of materials, environment, and stress and strain/strain rate, subsequently referred to by the acronym open-quotes MESSclose quotes by some of the group members, were noted. The element of time (i.e., evolution of these variables with time) was emphasized. It was also suggested that the group might want to consider the related topics of inspection capabilities, operational variables, degradation remedies, and validity of test data, and some background information in these areas was provided. The presentation given by Peter Millet during the Plenary Session was reviewed; Specifically, the chemical aspects and the degradation from the secondary side of the steam generator were noted. The main issues discussed during the October 1995 EPRI meeting on secondary side corrosion were reported, and a listing of the potential SG tube degradations was provided and discussed

  10. S. 575: A bill entitled the Radon Testing for Safe Schools Act, introduced in the US Senate, One Hundred Second Congress, First Session, March 6, 1991

    International Nuclear Information System (INIS)

    Anon.

    1991-01-01

    This bill was introduced into the US Senate on March 6, 1991 to require radon testing in schools. Radon may be especially hazardous to small children who spend a substantial portion of a day in school buildings. On April 20, 1989, the Administrator of the Environmental Protection Agency issued a national advisory recommending that all schools be tested for radon. There is a need for the federal government to provide financial assistance to states and local educational agencies for implementation of measures to reduce elevated levels of radon

  11. A field test for companded single sideband modulation Implications for capacity enhancement and transmission planning

    Science.gov (United States)

    Wallace, E.; Adams, C.; Arnstein, D.

    A series of field tests of companded single sideband modulation (CSSB) technique for use in the Intelsat system is described. A 12-channel circuit group was tested between switches in Pittsburgh, and the Deutsche Bundespost (DBP) in Frankfurt via the Etam and Raisting satellite earth stations. A transponder bulk that included existing FDM-FM carriers was chosen to match the typical, Intelsat operating conditions, thus permitting the compatibility of FDM/FM and CSSB to be examined simultaneously. Results of objective performance tests are discussed, and a description of several subjective testing techniques is also given.

  12. Intersections and Unions of Session Types

    Directory of Open Access Journals (Sweden)

    Coşku Acay

    2017-02-01

    Full Text Available Prior work has extended the deep, logical connection between the linear sequent calculus and session-typed message-passing concurrent computation with equi-recursive types and a natural notion of subtyping. In this paper, we extend this further by intersection and union types in order to express multiple behavioral properties of processes in a single type. We prove session fidelity and absence of deadlock and illustrate the expressive power of our system with some simple examples. We observe that we can represent internal and external choice by intersection and union, respectively, which was previously suggested by Padovani for a different language of session types motivated by operational rather than logical concerns.

  13. In-flight and ground testing of single event upset sensitivity in static RAMs

    International Nuclear Information System (INIS)

    Johansson, K.; Dyreklev, P.; Granbom, B.; Calvet, C.; Fourtine, S.; Feuillatre, O.

    1998-01-01

    This paper presents the results from in-flight measurements of single event upsets (SEU) in static random access memories (SRAM) caused by the atmospheric radiation environment at aircraft altitudes. The memory devices were carried on commercial airlines at high altitude and mainly high latitudes. The SEUs were monitored by a Component Upset Test Equipment (CUTE), designed for this experiment. The in flight results are compared to ground based testing with neutrons from three different sources

  14. Hydrogeological study of single water conducting fracture using a crosshole hydraulic test apparatus

    International Nuclear Information System (INIS)

    Yamamoto, Hajime; Shimo, Michito; Yamamoto, Takuya

    1998-03-01

    The Crosshole Injection Test Apparatus has been constructed to evaluate the hydraulic properties and conditions, such as hydraulic conductivity and its anisotropy, storage coefficient, pore pressure etc. within a rock near a drift. The construction started in FY93 and completed on August FY96 as a set of equipments for the use of crosshole hydraulic test, which is composed of one injection borehole instrument, one observation borehole instrument and a set of on-ground instrument. In FY96, in-situ feasibility test was conducted at a 550 m level drift in Kamaishi In Situ Test Site which has been operated by PNC, and the performance of the equipment and its applicability to various types of injection method were confirmed. In this year, a hydrogeological investigation on the single water conducting fracture was conducted at a 250 m level drift in Kamaishi In Situ Test Site, using two boreholes, KCH-3 and KCH-4, both of which are 30 m depth and inclined by 45 degrees from the surface. Pressure responses at the KCH-3 borehole during the drilling of KCH-4 borehole, the results of Borehole TV logging and core observation indicated that a major conductive single-fracture was successfully isolated by the packers. As a result of a series of the single-hole and the crosshole tests (sinusoidal and constant flowrate test), the hydraulic parameters of the single-fracture (such as hydraulic conductivity and storage coefficient) were determined. This report shows all the test result, analysed data, and also describes the hydro-geological structure near the drift. (author)

  15. Single-Cylinder Diesel Engine Tests with Unstabilized Water-in-Fuel Emulsions

    Science.gov (United States)

    1978-08-01

    A single-cylinder, four-stroke cycle diesel engine was operated on unstabilized water-in-fuel emulsions. Two prototype devices were used to produce the emulsions on-line with the engine. More than 350 test points were run with baseline diesel fuel an...

  16. Microwave testing of high-Tc based direct current to a single flux quantum converter

    DEFF Research Database (Denmark)

    Kaplunenko, V. K.; Fischer, Gerd Michael; Ivanov, Z. G.

    1994-01-01

    Design, simulation, and experimental investigations of a direct current to a single flux quantum converter loaded with a Josephson transmission line and driven by an external 70 GHz microwave oscillator are reported. The test circuit includes nine YBaCuO Josephson junctions aligned on the grain...

  17. Should the diagnosis of COPD be based on a single spirometry test?

    NARCIS (Netherlands)

    Schermer, T.R.; Robberts, B.; Crockett, A.J.; Thoonen, B.P.; Lucas, A.; Grootens, J.; Smeele, I.J.; Thamrin, C.; Reddel, H.K.

    2016-01-01

    Clinical guidelines indicate that a chronic obstructive pulmonary disease (COPD) diagnosis is made from a single spirometry test. However, long-term stability of diagnosis based on forced expiratory volume in 1 s over forced vital capacity (FEV1/FVC) ratio has not been reported. In primary care

  18. Should the diagnosis of COPD be based on a single spirometry test?

    NARCIS (Netherlands)

    Schermer, T.R.J.; Robberts, B.; Crockett, A.J.; Thoonen, B.P.A.; Lucas, A.; Grootens, J.; Smeele, I.J.; Thamrin, C.; Reddel, H.K.

    2016-01-01

    Clinical guidelines indicate that a chronic obstructive pulmonary disease (COPD) diagnosis is made from a single spirometry test. However, long-term stability of diagnosis based on forced expiratory volume in 1 s over forced vital capacity (FEV1/FVC) ratio has not been reported. In primary care

  19. A single well pumping and recovery test to measure in situ acrotelm transmissivity in raised bogs

    NARCIS (Netherlands)

    Schaaf, van der S.

    2004-01-01

    A quasi-steady-state single pit pumping and recovery test to measure in situ the transmissivity of the highly permeable upper layer of raised bogs, the acrotelm, is described and discussed. The basic concept is the expanding depression cone during both pumping and recovery. It is shown that applying

  20. Generalized Single-Case Randomization Tests: Flexible Analyses for a Variety of Situations.

    Science.gov (United States)

    Levin, Joel R.; Wampold, Bruce E.

    1999-01-01

    Presents a general class of single-case statistical procedures derived from previously developed nonparametric randomization tests. Designs are illustrated that focus on the general and comparative effectiveness of alternative interventions, multiple units with differentiable characteristics, and multiple outcome measures. Provides operational…

  1. Fabrication and testing of full-length single-cell externally fueled converters for thermionic reactors

    International Nuclear Information System (INIS)

    Schock, A.

    1994-01-01

    The preceding paper described designs and analyses of thermionic reactors employing full-core-length single-cell converters with their heated emitters located on the outside of their internally cooled collectors, and it presented results of detailed parametric analyses which illustrate the benefits of this unconventional design. The present paper describes the fabrication and testing of full-length prototypical converters, both unfueled and fueled, and presents parametric results of electrically heated tests. The unfueled converter tests demonstrated the practicality of operating such long converters without shorting across a 0.3-mm interelectrode gap. They produced a measured peak output of 751 watts(e) from a single diode and a peak efficiency of 15.4%. The fueled converter tests measured the parametric performance of prototypic UO 2 -fueled converters designed for subsequent in-pile testing. They employed revolver-shaped tungsten elements with a central emitter hole surrounded by six fuel chambers. The full-length converters were heated by a water-cooled RF-induction coil inside an ion-pumped vacuum chamber. This required development of high-vacuum coaxial RF feedthroughs. In-pile test rules required multiple containment of the UO 2 -fuel, which complicated the fabrication of the test article and required successful development of techniques for welding tungsten and other refractory components. The tests measured a peak power output of 530 watts(e) or 7.1 watts/cm 2 at an efficiency of 11.5%

  2. Monitorização ambulatorial da pressão arterial em indivíduos normotensos submetidos a duas sessões únicas de exercícios: resistido e aeróbio Ambulatory blood pressure monitoring in normotensive individuals undergoing two single exercise sessions: resistive exercise training and aerobic exercise training

    Directory of Open Access Journals (Sweden)

    Ambrosina Maria Lignani de Miranda Bermudes

    2004-01-01

    Full Text Available OBJETIVO: Investigar a influência de duas sessões únicas de exercício resistido (circuito com pesos e aeróbio sobre as alterações pressóricas, em indivíduos sedentários e normotensos. MÉTODOS: Foram avaliados pela monitorização numa situação controle, sem realização de exercícios (MAPA 1 25 indivíduos, após exercício resistido (MAPA 2 e após exercício aeróbio (MAPA 3. Os exercícios resistidos foram realizados sob forma de circuito com pesos, com intensidade de 40% da força máxima individual e os exercícios aeróbicos em cicloergômetro, com intensidade entre 60% e 70% da freqüência cardíaca (FC máxima alcançada no teste ergométrico. RESULTADOS: A pressão arterial sistólica (PAS de 24h e sub-períodos vigília e sono não apresentaram variações estatisticamente significantes quando comparada à MAPA2 e MAPA3 e MAPA2 e MAPA3 entre si. A pressão arterial diastólica (PAD de 24h e diurna apresentaram reduções significantes (POBJECTIVE: To assess the influence of 2 single exercise sessions on blood pressure in sedentary normotensive individuals: one of resistive exercise training (circuit weight training and the other of aerobic exercise training. METHODS: Using ambulatory blood pressure monitoring, this study assessed 25 individuals as follows: in a controlled situation at rest (ABPM 1; after resistive exercise training (ABPM 2; and after aerobic exercise training (ABPM 3. Resistive exercise training was performed as circuit weight training with an intensity of 40% of each individual's maximum strength. The aerobic exercise training was performed on a cycloergometer with intensity between 60% and 70% of the maximum heart rate (HR reached during previous exercise testing. RESULTS: Systolic blood pressure (SBP values during 24 hours and during subperiods of wakefulness and sleep showed no statistically significant variations when the results obtained at rest were compared with those of ABPM2 and ABPM3, and when

  3. [Training of residents in obstetrics and gynecology: Assessment of an educational program including formal lectures and practical sessions using simulators].

    Science.gov (United States)

    Jordan, A; El Haloui, O; Breaud, J; Chevalier, D; Antomarchi, J; Bongain, A; Boucoiran, I; Delotte, J

    2015-01-01

    Evaluate an educational program in the training of residents in gynecology-obstetrics (GO) with a theory session and a practical session on simulators and analyze their learning curve. Single-center prospective study, at the university hospital (CHU). Two-day sessions were leaded in April and July 2013. An evaluation on obstetric and gynecological surgery simulator was available to all residents. Theoretical knowledge principles of obstetrics were evaluated early in the session and after formal lectures was taught to them. At the end of the first session, a satisfaction questionnaire was distributed to all participants. Twenty residents agreed to participate to the training sessions. Evaluation of theoretical knowledge: at the end of the session, the residents obtained a significant improvement in their score on 20 testing knowledge. Obstetrical simulator: a statistically significant improvement in scores on assessments simulator vaginal delivery between the first and second session. Subjectively, a larger increase feeling was seen after breech delivery simulation than for the cephalic vaginal delivery. However, the confidence level of the resident after breech delivery simulation has not been improved at the end of the second session. Simulation in gynecological surgery: a trend towards improvement in the time realized on the peg-transfer between the two sessions was noted. In the virtual simulation, no statistically significant differences showed, no improvement for in salpingectomy's time. Subjectively, the residents felt an increase in the precision of their gesture. Satisfaction: All residents have tried the whole program. They considered the pursuit of these sessions on simulators was necessary and even mandatory. The approach chosen by this structured educational program allowed a progression for the residents, both objectively and subjectively. This simulation program type for the resident's training would use this tool in assessing their skills and develop

  4. Tank selection for Light Duty Utility Arm (LDUA) system hot testing in a single shell tank

    Energy Technology Data Exchange (ETDEWEB)

    Bhatia, P.K.

    1995-01-31

    The purpose of this report is to recommend a single shell tank in which to hot test the Light Duty Utility Arm (LDUA) for the Tank Waste Remediation System (TWRS) in Fiscal Year 1996. The LDUA is designed to utilize a 12 inch riser. During hot testing, the LDUA will deploy two end effectors (a High Resolution Stereoscopic Video Camera System and a Still/Stereo Photography System mounted on the end of the arm`s tool interface plate). In addition, three other systems (an Overview Video System, an Overview Stereo Video System, and a Topographic Mapping System) will be independently deployed and tested through 4 inch risers.

  5. Session management for web-based healthcare applications.

    Science.gov (United States)

    Wei, L; Sengupta, S

    1999-01-01

    In health care systems, users may access multiple applications during one session of interaction with the system. However, users must sign on to each application individually, and it is difficult to maintain a common context among these applications. We are developing a session management system for web-based applications using LDAP directory service, which will allow single sign-on to multiple web-based applications, and maintain a common context among those applications for the user. This paper discusses the motivations for building this system, the system architecture, and the challenges of our approach, such as the session objects management for the user, and session security.

  6. First steps towards fuel cells testing harmonisation: Procedures and parameters for single cell performance evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Lunghi, P. [Department of Industrial Engineering, University of Perugia, Via Duranti 93, Perugia (Italy); Ubertini, S. [Department of Mechanical Engineering, University of Rome ' ' Tor Vergata' ' , Via di Torvergata, 110, Rome (Italy)

    2004-01-01

    The great interest in Fuel Cell Systems, combined with the innovation of the device itself, has led to a huge developmental effort to make the steps necessary for future FC plant commissioning. The clearest and most effective way to evaluate the performance of a fuel cell is to measure it directly and, since few fuel cell test rigs are available at the moment, standard experimental procedures have not been realized so far. Our research group is currently performing single cell testing at the University of Perugia fuel cell laboratory and particular emphasis has been put on the definition of procedures and the testing of parameterisation. The work team strongly believes that this is the key to effective system testing and reliable performance evaluation. In this work, the test parameterisation developed by the team, and the resulting advanced control procedure used for a single MCFC experimental characterization are presented. Efforts have been dedicated to obtain some relevant non-dimensional parameters to allow an easy understanding of the results and quick comparisons with other tests under different operating conditions, or with results obtained on different cells eventually tested in different laboratories. The authors strongly emphasise this topic to avoid the data that developers and research institutions collect being of no practical use due to a lack of shared rules. (Abstract Copyright [2003], Wiley Periodicals, Inc.)

  7. Experimental results of single screw mechanical tests: a follow-up to SAND2005-6036.

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Sandwook; Lee, Kenneth L.; Korellis, John S.; McFadden, Sam X.

    2006-08-01

    The work reported here was conducted to address issues raised regarding mechanical testing of attachment screws described in SAND2005-6036, as well as to increase the understanding of screw behavior through additional testing. Efforts were made to evaluate fixture modifications and address issues of interest, including: fabrication of 45{sup o} test fixtures, measurement of the frictional load from the angled fixture guide, employment of electromechanical displacement transducers, development of a single-shear test, and study the affect of thread start orientation on single-shear behavior. A286 and 302HQ, No.10-32 socket-head cap screws were tested having orientations with respect to the primary loading axis of 0{sup 0}, 45{sup o}, 60{sup o}, 75{sup o} and 90{sup o} at stroke speeds 0,001 and 10 in/sec. The frictional load resulting from the angled screw fixture guide was insignificant. Load-displacement curves of A286 screws did not show a minimum value in displacement to failure (DTF) for 60{sup o} shear tests. Tests of 302HQ screws did not produce a consistent trend in DTF with load angle. The effect of displacement rate on DTF became larger as shear angle increased for both A286 and 302HQ screws.

  8. Single-well interference slug tests to assess the vertical hydraulic conductivity of unconsolidated aquifers

    Science.gov (United States)

    Paradis, Daniel; Lefebvre, René

    2013-01-01

    SummaryMeaningful understanding of flow and solute transport in general requires the knowledge of hydraulic conductivity and its anisotropy. Various field methods allow the measurement of the horizontal component (Kh), but vertical hydraulic conductivity (Kv) is rarely measured, for lack of practical field tests. This paper proposes vertical interference slug tests, an adaptation of inter-well interference slug tests to a single well, for the efficient field measurement of Kv. The test is carried out in a single well between a stress and an observation interval that are vertically isolated with a three-packer assembly. An instantaneous pressure pulse is induced in the stress interval and resulting drawdowns are recorded in both the stress and the observation intervals. In a proof-of-concept field study, 12 vertical interference tests were carried out sequentially along a fully-screened well across a moderately heterogeneous and highly anisotropic aquifer made up of littoral silts and sands. A direct-push method was used to install the well, which was completed without sand-pack to allow the natural collapse of sediments in the thin annular space around the screen. Direct-push wells allow the measurement of in situ hydraulic properties of sediments and minimize well construction interferences with hydraulic tests. Drawdowns measured in stress and observation intervals of multiple tests were simultaneously inverted numerically to reconstruct heterogeneous profiles of Kh, hydraulic conductivity anisotropy (Kv/Kh), and specific storage (Ss). Results were validated by comparison of observed versus predicted drawdowns and with field and laboratory measurements of Kh and Kv made along the tested well. Results indicate that the profile of Kv values obtained with vertical interference slug tests follows a similar pattern with depth than the profile with lab measurements made with a permeameter on soil samples collected in the same intervals as the interference tests, which

  9. Screening of nanosatellite microprocessors using californium single-event latch-up test results

    Science.gov (United States)

    Tomioka, Takahiro; Okumura, Yuta; Masui, Hirokazu; Takamiya, Koichi; Cho, Mengu

    2016-09-01

    A single-event latch-up (SEL) test using a 252Cf radioisotope was carried out. The results were compared with those of a proton test and from observation in orbit. A radioisotope can reproduce phenomena observed in orbit that are caused by protons. Considering the inexpensive nature of the 252Cf test, it is more suitable for nanosatellites that require low cost and fast delivery. A SEL occurrence rate of a commercial-off-the-shelf microprocessor was derived from the ground test results. The 252Cf test provided a SEL rate approximately 1×106 times greater than that in orbit. This data can be used to derive the minimum SEL occurrence rate in orbit and help satellite designers to evaluate the risk of SEL and take measures if necessary.

  10. Measurement of LNAPL flux using single-well intermittent mixing tracer dilution tests.

    Science.gov (United States)

    Smith, Tim; Sale, Tom; Lyverse, Mark

    2012-01-01

    The stability of subsurface Light Nonaqueous Phase Liquids (LNAPLs) is a key factor driving expectations for remedial measures at LNAPL sites. The conventional approach to resolving LNAPL stability has been to apply Darcy's Equation. This paper explores an alternative approach wherein single-well tracer dilution tests with intermittent mixing are used to resolve LNAPL stability. As a first step, an implicit solution for single-well intermittent mixing tracer dilution tests is derived. This includes key assumptions and limits on the allowable time between intermittent mixing events. Second, single-well tracer dilution tests with intermittent mixing are conducted under conditions of known LNAPL flux. This includes a laboratory sand tank study and two field tests at active LNAPL recovery wells. Results from the sand tank studies indicate that LNAPL fluxes in wells can be transformed into formation fluxes using corrections for (1) LNAPL thicknesses in the well and formation and (2) convergence of flow to the well. Using the apparent convergence factor from the sand tank experiment, the average error between the known and measured LNAPL fluxes is 4%. Results from the field studies show nearly identical known and measured LNAPL fluxes at one well. At the second well the measured fluxes appear to exceed the known value by a factor of two. Agreement between the known and measured LNAPL fluxes, within a factor of two, indicates that single-well tracer dilution tests with intermittent mixing can be a viable means of resolving LNAPL stability. © 2012, The Author(s). Ground Water © 2012, National Ground Water Association.

  11. Formal description of the OSI session layer: session service

    NARCIS (Netherlands)

    van Sinderen, Marten J.; van Eijk, P.H.J.; Vissers, C.A.; Diaz, M.

    1989-01-01

    The LOTOS formal description of the OSI session service is presented on basis of specification samples from the full description, giving account of how specification styles and session service architectural elements are reflected in the description. Both information (data types) and process

  12. Relative 11C-PiB Delivery as a Proxy of Relative CBF: Quantitative Evaluation Using Single-Session 15O-Water and 11C-PiB PET.

    Science.gov (United States)

    Chen, Yin J; Rosario, Bedda L; Mowrey, Wenzhu; Laymon, Charles M; Lu, Xueling; Lopez, Oscar L; Klunk, William E; Lopresti, Brian J; Mathis, Chester A; Price, Julie C

    2015-08-01

    The primary goal of this study was to assess the suitability of (11)C-Pittsburgh compound B ((11)C-PiB) blood-brain barrier delivery (K1) and relative delivery (R1) parameters as surrogate indices of cerebral blood flow (CBF), with a secondary goal of directly examining the extent to which simplified uptake measures of (11)C-PiB retention (amyloid-β load) may be influenced by CBF, in a cohort of controls and patients with mild cognitive impairment (MCI) and Alzheimer disease (AD). Nineteen participants (6 controls, 5 AD, 8 MCI) underwent MR imaging, (15)O-water PET, and (11)C-PiB PET in a single session. Fourteen regions of interest (including cerebellar reference region) were defined on MR imaging and applied to dynamic coregistered PET to generate time-activity curves. Multiple analysis approaches provided regional (15)O-water and (11)C-PiB measures of delivery and (11)C-PiB retention that included compartmental modeling distribution volume ratio (DVR), arterial- and reference-based Logan DVR, simplified reference tissue modeling 2 (SRTM2) DVR, and standardized uptake value ratios. Spearman correlation was performed among delivery measures (i.e., (15)O-water K1 and (11)C-PiB K1, relative K1 normalized to cerebellum [Rel-K1-Water and Rel-K1-PiB], and (11)C-PiB SRTM2-R1) and between delivery measures and (11)C-PiB retention, using the Bonferroni method for multiple-comparison correction. Primary analysis showed positive correlations (ρ ≈0.2-0.5) between (15)O-water K1 and (11)C-PiB K1 that did not survive Bonferroni adjustment. Significant positive correlations were found between Rel-K1-Water and Rel-K1-PiB and between Rel-K1-Water and (11)C-PiB SRTM2-R1 (ρ ≈0.5-0.8, P PiB retention and relative (11)C-PiB delivery measures (but not (15)O-water delivery measures) in primary cortical areas that arose only after accounting for cerebrospinal fluid dilution. (11)C-PiB SRTM2-R1 is highly correlated with regional relative CBF, as measured by (15)O-water K1

  13. Single-task and dual-task tandem gait test performance after concussion.

    Science.gov (United States)

    Howell, David R; Osternig, Louis R; Chou, Li-Shan

    2017-07-01

    To compare single-task and dual-task tandem gait test performance between athletes after concussion with controls on observer-timed, spatio-temporal, and center-of-mass (COM) balance control measurements. Ten participants (19.0±5.5years) were prospectively identified and completed a tandem gait test protocol within 72h of concussion and again 1 week, 2 weeks, 1 month, and 2 months post-injury. Seven uninjured controls (20.0±4.5years) completed the same protocol in similar time increments. Tandem gait test trials were performed with (dual-task) and without (single-task) concurrently performing a cognitive test as whole-body motion analysis was performed. Outcome variables included test completion time, average tandem gait velocity, cadence, and whole-body COM frontal plane displacement. Concussion participants took significantly longer to complete the dual-task tandem gait test than controls throughout the first 2 weeks post-injury (mean time=16.4 [95% CI: 13.4-19.4] vs. 10.1 [95% CI: 6.4-13.7] seconds; p=0.03). Single-task tandem gait times were significantly lower 72h post-injury (p=0.04). Dual-task cadence was significantly lower for concussion participants than controls (89.5 [95% CI: 68.6-110.4] vs. 127.0 [95% CI: 97.4-156.6] steps/minute; p=0.04). Moderately-high to high correlations between tandem gait test time and whole-body COM medial-lateral displacement were detected at each time point during dual-task gait (r s =0.70-0.93; p=0.03-0.001). Adding a cognitive task during the tandem gait test resulted in longer detectable deficits post-concussion compared to the traditional single-task tandem gait test. As a clinical tool to assess dynamic motor function, tandem gait may assist with return to sport decisions after concussion. Copyright © 2017 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  14. Estimation of single crystal elastic constants using ultrasonic testing - a feasibility study

    International Nuclear Information System (INIS)

    Phani Kumar, K.K.; Rentala, Vamsi Krishna; Gautam, Jaiprakash; Mylavarapu, Phani

    2015-01-01

    Estimation of single crystal elastic constants (SCEC) of metallic materials is of paramount importance in the development of crystal plasticity based models as well as for studying the effect of microstructure on wave propagation. SCEC are usually determined destructively by tensile and shear loading a single crystal specimen. These constants can also be estimated non-destructively, using X-ray diffraction measurements on a polycrystalline specimen. However, the aforementioned procedures have a limitation of either the sample size (in case of X-ray diffraction) or, availability of single crystal (in case of destructive testing). Hence, in this study, an effort has been undertaken to estimate SCEC by subjecting polycrystalline specimens to ultrasonic testing. Ultrasonic longitudinal and shear velocities, longitudinal attenuation coefficient and ultrasonic backscattered grain noise will be measured on pure Cu specimen. Further, these parameters will also be calculated analytically using existing relationships involving, elastic constants, grain size probability level, ultrasonic longitudinal and shear wave velocities, attenuation coefficient and backscattered grain noise. By minimizing the difference between experimentally measured and analytically calculated ultrasonic parameters, an attempt will be made to estimate single crystal elastic constants. (author)

  15. Single well surfactant test to evaluate surfactant floods using multi tracer method

    Science.gov (United States)

    Sheely, Clyde Q.

    1979-01-01

    Data useful for evaluating the effectiveness of or designing an enhanced recovery process said process involving mobilizing and moving hydrocarbons through a hydrocarbon bearing subterranean formation from an injection well to a production well by injecting a mobilizing fluid into the injection well, comprising (a) determining hydrocarbon saturation in a volume in the formation near a well bore penetrating formation, (b) injecting sufficient mobilizing fluid to mobilize and move hydrocarbons from a volume in the formation near the well bore, and (c) determining the hydrocarbon saturation in a volume including at least a part of the volume of (b) by an improved single well surfactant method comprising injecting 2 or more slugs of water containing the primary tracer separated by water slugs containing no primary tracer. Alternatively, the plurality of ester tracers can be injected in a single slug said tracers penetrating varying distances into the formation wherein the esters have different partition coefficients and essentially equal reaction times. The single well tracer method employed is disclosed in U.S. Pat. No. 3,623,842. This method designated the single well surfactant test (SWST) is useful for evaluating the effect of surfactant floods, polymer floods, carbon dioxide floods, micellar floods, caustic floods and the like in subterranean formations in much less time and at much reduced cost compared to conventional multiwell pilot tests.

  16. Measurement of single-top cross section and test of anomalous $Wtb$ coupling

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Ji-Eun [Seoul National Univ. (Korea, Republic of)

    2010-01-01

    The top quark is most often produced in tt pairs via the strong interaction, however electroweak production of a singly-produced top quark is also possible. Electroweak single-top production is more difficult to observe than tt production. Studying single-top production is important for the following reasons. It provides direct measurement of the CKM matrix element and also single-top events are a background to several searches for SM or non-SM signals, such as Higgs boson searches. The information of spin polarization of top-quark can be used to t est anomalous W-t-b coupling. This thesis describes the result of a measurement of single-top cross-section and a test of anomalous W-t-b coupling using 4.8 f b-1 of data collected by the CDF Run II experiment at the Fermilab Tevatron. The measured cross-section is 1.83$+0.7\\atop{-0.6}$ pb and measured limit of |Vtb| is 0.41 at 95% CL. The fraction of V+A coupling is 0 ± 28 (%).

  17. A New Kind of Single-Well Tracer Test for Assessing Subsurface Heterogeneity

    Science.gov (United States)

    Hansen, S. K.; Vesselinov, V. V.; Lu, Z.; Reimus, P. W.; Katzman, D.

    2017-12-01

    Single-well injection-withdrawal (SWIW) tracer tests have historically been interpreted using the idealized assumption of tracer path reversibility (i.e., negligible background flow), with background flow due to natural hydraulic gradient being an un-modeled confounding factor. However, we have recently discovered that it is possible to use background flow to our advantage to extract additional information about the subsurface. To wit: we have developed a new kind of single-well tracer test that exploits flow due to natural gradient to estimate the variance of the log hydraulic conductivity field of a heterogeneous aquifer. The test methodology involves injection under forced gradient and withdrawal under natural gradient, and makes use of a relationship, discovered using a large-scale Monte Carlo study and machine learning techniques, between power law breakthrough curve tail exponent and log-hydraulic conductivity variance. We will discuss how we performed the computational study and derived this relationship and then show an application example in which our new single-well tracer test interpretation scheme was applied to estimation of heterogeneity of a formation at the chromium contamination site at Los Alamos National Laboratory. Detailed core hole records exist at the same site, from which it was possible to estimate the log hydraulic conductivity variance using a Kozeny-Carman relation. The variances estimated using our new tracer test methodology and estimated by direct inspection of core were nearly identical, corroborating the new methodology. Assessment of aquifer heterogeneity is of critical importance to deployment of amendments associated with in-situ remediation strategies, since permeability contrasts potentially reduce the interaction between amendment and contaminant. Our new tracer test provides an easy way to obtain this information.

  18. Critical evaluation of the pulsed laser method for single event effects testing and fundamental studies

    International Nuclear Information System (INIS)

    Melinger, J.S.; Buchner, S.; McMorrow, D.; Stapor, W.J.; Weatherford, T.R.; Campbell, A.B.; Eisen, H.

    1994-01-01

    In this paper the authors present an evaluation of the pulsed laser as a technique for single events effects (SEE) testing. They explore in detail the important optical effects, such as laser beam propagation, surface reflection, and linear and nonlinear absorption, which determine the nature of laser-generated charge tracks in semiconductor materials. While there are differences in the structure of laser- and ion-generated charge tracks, they show that in many cases the pulsed laser remains an invaluable tool for SEE testing. Indeed, for several SEE applications, they show that the pulsed laser method represents a more practical approach than conventional accelerator-based methods

  19. Testing of plain and fibrous concrete single cavity prestressed concrete reactor vessel models

    International Nuclear Information System (INIS)

    Oland, C.B.

    1985-01-01

    Two single-cavity prestressed concrete reactor vessel (PCRV) models were fabricated and tested to failure to demonstrate the structural response and ultimate pressure capacity of models cast from high-strength concretes. Concretes with design compressive strengths in excess of 70 MPa (10,000 psi) were developed for this investigation. One model was cast from plain concrete and failed in shear at the head region. The second model was cast from fiber reinforced concrete and failed by rupturing the circumferential prestressing at the sidewall of the structure. The tests also demonstrated the capabilities of the liner system to maintain a leak-tight pressure boundary. 3 refs., 4 figs

  20. Effectiveness Analysis of a Non-Destructive Single Event Burnout Test Methodology

    CERN Document Server

    Oser, P; Spiezia, G; Fadakis, E; Foucard, G; Peronnard, P; Masi, A; Gaillard, R

    2014-01-01

    It is essential to characterize power MosFETs regarding their tolerance to destructive Single Event Burnouts (SEB). Therefore, several non-destructive test methods have been developed to evaluate the SEB cross-section of power devices. A power MosFET has been evaluated using a test circuit, designed according to standard non-destructive test methods discussed in the literature. Guidelines suggest a prior adaptation of auxiliary components to the device sensitivity before the radiation test. With the first value chosen for the de-coupling capacitor, the external component initiated destructive events and affected the evaluation of the cross-section. As a result, the influence of auxiliary components on the device cross-section was studied. This paper presents the obtained experimental results, supported by SPICE simulations, to evaluate and discuss how the circuit effectiveness depends on the external components.

  1. Single-well "push-pull" partitioning tracer test for NAPL detection in the subsurface.

    Science.gov (United States)

    Istok, Jonathan D; Field, Jennifer A; Schroth, Martin H; Davis, Brian M; Dwarakanath, Varadarajan

    2002-06-15

    Previous environmental applications of partitioning tracer tests to detect and quantify nonaqueous phase liquid (NAPL) contamination in the subsurface have been limited to well-to-well tests. However, theory and numerical modeling suggests that single-well injection-extraction ("push-pull") partitioning tracer tests can also potentially detect and quantify NAPL contamination. In this type of test, retardation factors for injected partitioning tracers are estimated from the increase in apparent dispersion observed in extraction-phase breakthrough curves in the presence of NAPL. A series of laboratory push-pull tests was conducted in physical aquifer models (PAMs) packed with natural aquifer sediment prepared with and without the presence of trichloroethene (TCE) NAPL. Field tests were conducted in an aquifer contaminated with petroleum hydrocarbon NAPL. Injected test solutions contained a suite of partitioning and conservative (nonpartitioning) alcohol tracers. Laboratory push-pull partitioning tracer tests were able to detect and quantify sorption of partitioning tracers to aquifer sediment (in the absence of NAPL) and to detect NAPL when it was present. NAPL saturations computed from estimated retardation factors bracketed those computed from known volumes of emplaced NAPL in the sediment pack. However, numerical modeling with assumed homogeneous NAPL distribution and linear equilibrium partitioning of tracers between aqueous and NAPL phases was unable to reproduce all features of observed breakthrough curves. Excavation of the sediment pack after all tests indicated that a portion of the emplaced NAPL had sunk to the bottom of the PAM invalidating the modeling assumption of homogeneous NAPL distribution. Moreover, the apparent dispersion in extraction-phase breakthrough curves decreased when the injection-extraction pumping rate was decreased, suggesting that mass transfer limitations existed during laboratory tests. Field push-pull partitioning tracer tests were

  2. Fabrication and Testing of Full-Length Single-Cell Externally Fueled Converters for Thermionic Reactors

    Energy Technology Data Exchange (ETDEWEB)

    Schock, Alfred

    1994-06-01

    The preceding paper described designs and analyses of thermionic reactors employing full-core-length single-cell converters with their heated emitters located on the outside of their internally cooled collectors, and it presented results of detailed parametric analyses which illustrate the benefits of this unconventional design. The present paper describes the fabrication and testing of full-length prototypical converters, both unfueled and fueled, and presents parametric results of electrically heated tests. The unfueled converter tests demonstrated the practicality of operating such long converters without shorting across a 0.3-mm interelectrode gap. They produced a measured peak output of 751 watts(e) from a single diode and a peak efficiency of 15.4%. The fueled converter tests measured the parametric performance of prototypic UO(subscript 2)-fueled converters designed for subsequent in-pile testing. They employed revolver-shaped tungsten elements with a central emitter hole surrounded by six fuel chambers. The full-length converters were heated by a water-cooled RF-induction coil inside an ion-pumped vacuum chamber. This required development of high-vacuum coaxial RF feedthroughs. In-pile test rules required multiple containment of the UO (subscript 2)-fuel, which complicated the fabrication of the test article and required successful development of techniques for welding tungsten and other refractory components. The test measured a peak power output of 530 watts(e) or 7.1 watts/cm (superscript 2) at an efficiency of 11.5%. There are three copies in the file. Cross-Reference a copy FSC-ESD-217-94-529 in the ESD files with a CID #8574.

  3. Intra-session test-retest reliability of magnitude and structure of center of pressure from the Nintendo Wii Balance Board™ for a visually impaired and normally sighted population.

    Science.gov (United States)

    Jeter, Pamela E; Wang, Jiangxia; Gu, Jialiang; Barry, Michael P; Roach, Crystal; Corson, Marilyn; Yang, Lindsay; Dagnelie, Gislin

    2015-02-01

    Individuals with visual impairment (VI) have irreparable damage to one of the input streams contributing to postural stability. Here, we evaluated the intra-session test-retest reliability of the Wii Balance Board (WBB) for measuring Center of Pressure (COP) magnitude and structure, i.e. approximate entropy (ApEn) in fourteen legally blind participants and 21 participants with corrected-to-normal vision. Participants completed a validated balance protocol which included four sensory conditions: double-leg standing on a firm surface with eyes open (EO-firm); a firm surface with eyes closed (EC-firm); a foam surface with EO (EO-foam); and a foam surface with EC (EC-foam). Participants performed the full balance protocol twice during the session, separated by a period of 15min, to determine the intraclass correlation coefficient (ICC). Absolute reliability was determined by the standard error of measurement (SEM). The minimal difference (MD) was estimated to determine clinical significance for future studies. COP measures were derived from data sent by the WBB to a laptop via Bluetooth. COP scores increased with the difficulty of sensory condition indicating WBB sensitivity (all p<0.01). ICCs in the VI group ranged from 0.73 to 0.95, indicating high to very high correlations, and the normal group showed moderate to very high ICCs (0.62-0.94). The SEM was comparable between groups regardless of between-subject variability. The reliability of the WBB makes it practical to screen for balance impairment among VI persons. Copyright © 2014 Elsevier B.V. All rights reserved.

  4. Predicting muscle forces during the propulsion phase of single leg triple hop test.

    Science.gov (United States)

    Alvim, Felipe Costa; Lucareli, Paulo Roberto Garcia; Menegaldo, Luciano Luporini

    2018-01-01

    Functional biomechanical tests allow the assessment of musculoskeletal system impairments in a simple way. Muscle force synergies associated with movement can provide additional information for diagnosis. However, such forces cannot be directly measured noninvasively. This study aims to estimate muscle activations and forces exerted during the preparation phase of the single leg triple hop test. Two different approaches were tested: static optimization (SO) and computed muscle control (CMC). As an indirect validation, model-estimated muscle activations were compared with surface electromyography (EMG) of selected hip and thigh muscles. Ten physically healthy active women performed a series of jumps, and ground reaction forces, kinematics and EMG data were recorded. An existing OpenSim model with 92 musculotendon actuators was used to estimate muscle forces. Reflective markers data were processed using the OpenSim Inverse Kinematics tool. Residual Reduction Algorithm (RRA) was applied recursively before running the SO and CMC. For both, the same adjusted kinematics were used as inputs. Both approaches presented similar residuals amplitudes. SO showed a closer agreement between the estimated activations and the EMGs of some muscles. Due to inherent EMG methodological limitations, the superiority of SO in relation to CMC can be only hypothesized. It should be confirmed by conducting further studies comparing joint contact forces. The workflow presented in this study can be used to estimate muscle forces during the preparation phase of the single leg triple hop test and allows investigating muscle activation and coordination. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Application of Phased Array Ultrasonic Testing (PAUT) on Single V-Butt Weld Integrity Determination

    International Nuclear Information System (INIS)

    Amry Amin Abas; Mohd Kamal Shah Shamsudin; Norhazleena Azaman

    2015-01-01

    Phased Array Ultrasonic Testing (PAUT) utilizes arrays of piezoelectric elements that are embedded in an epoxy base. The benefit of having such kind of array is that beam forming such as steering and focusing the beam front possible. This enables scanning patterns such as linear scan, sectorial scan and depth focusing scan to be performed. Ultrasonic phased array systems can potentially be employed in almost any test where conventional ultrasonic flaw detectors have traditionally been used. Weld inspection and crack detection are the most important applications, and these tests are done across a wide range of industries including aerospace, power generation, petrochemical, metal billet and tubular goods suppliers, pipeline construction and maintenance, structural metals, and general manufacturing. Phased arrays can also be effectively used to profile remaining wall thickness in corrosion survey applications. The benefits of PAUT are simplifying inspection of components of complex geometry, inspection of components with limited access, testing of welds with multiple angles from a single probe and increasing the probability of detection while improving signal-to-noise ratio. This paper compares the result of inspection on several specimens using PAUT as to digital radiography. The specimens are welded plates with single V-butt weld made of carbon steel. Digital radiography is done using blue imaging plate with x-ray source. PAUT is done using Olympus MX2 with 5 MHz probe consisting of 64 elements. The location, size and length of defect is compared. (author)

  6. Should the diagnosis of COPD be based on a single spirometry test?

    Science.gov (United States)

    Schermer, Tjard R; Robberts, Bas; Crockett, Alan J; Thoonen, Bart P; Lucas, Annelies; Grootens, Joke; Smeele, Ivo J; Thamrin, Cindy; Reddel, Helen K

    2016-09-29

    Clinical guidelines indicate that a chronic obstructive pulmonary disease (COPD) diagnosis is made from a single spirometry test. However, long-term stability of diagnosis based on forced expiratory volume in 1 s over forced vital capacity (FEV 1 /FVC) ratio has not been reported. In primary care subjects at risk for COPD, we investigated shifts in diagnostic category (obstructed/non-obstructed). The data were from symptomatic 40+ years (ex-)smokers referred for diagnostic spirometry, with three spirometry tests, each 12±2 months apart. The obstruction was based on post-bronchodilator FEV 1 /FVC smokers or SABA users at year 1. Change from non-obstructed to obstructed was more likely for males, older subjects, current smokers and patients with lower baseline FEV 1 % predicted, and less likely for those with higher baseline BMI. Up to one-third of symptomatic (ex-)smokers with baseline obstruction on diagnostic spirometry had shifted to non-obstructed when routinely re-tested after 1 or 2 years. Given the implications for patients and health systems of a diagnosis of COPD, it should not be based on a single spirometry test.

  7. A closed-form analytical solution for thermal single-well injection-withdrawal tests

    Science.gov (United States)

    Jung, Yoojin; Pruess, Karsten

    2012-03-01

    Thermal single-well injection-withdrawal (SWIW) tests entail pumping cold water into a hot and usually fractured reservoir, and monitoring the temperature recovery during subsequent backflow. Such tests have been proposed as a potential means to characterize properties of enhanced geothermal systems (EGS), such as fracture spacing, connectivity, and porosity. In this paper we develop an analytical solution for thermal SWIW tests, using an idealized model of a single vertical fracture with linear flow geometry embedded in impermeable conductive wall rocks. The analytical solution shows that the time dependence of temperature recovery is dominated by the heat exchange between fracture and matrix rock, but strong thermal diffusivities of rocks as compared to typical solute diffusivities are not necessarily advantageous for characterizing fracture-matrix interactions. The effect of fracture aperture on temperature recovery during backflow is weak, particularly when the fracture aperture is smaller than 0.1 cm. The solution also shows that temperature recovery during backflow is independent of the applied injection and backflow rates. This surprising result implies that temperature recovery is independent of the height of the fracture, or the specific fracture-matrix interface areas per unit fracture length, suggesting that thermal SWIW tests will not be able to characterize fracture growth that may be achieved by stimulation treatments.

  8. Impact of learners' role (active participant-observer or observer only) on learning outcomes during high-fidelity simulation sessions in anaesthesia: A single center, prospective and randomised study.

    Science.gov (United States)

    Blanié, Antonia; Gorse, Sophie; Roulleau, Philippe; Figueiredo, Samy; Benhamou, Dan

    2018-01-05

    The increasing use of high-fidelity simulation is limited by the imbalance between the growing number of students and the human resources available in such a way that all residents cannot play a role during scenarios. The learning outcomes of observers need to be studied. This prospective randomised study was approved by the institutional review board. Anaesthesia residents attending a one-day training session were enrolled. In each of the four scenarios, three residents played an active role while others observed in a separate room. All participants attended debriefing sessions. Residents were randomised between active participant-observer group (AP-O group) and observer group (O group). A similar questionnaire was distributed before, immediately after the session and after three months and included self-reported assessment of satisfaction, medical knowledge (noted 0-16), and non-technical skills. A hundred and four questionnaires were analysed. Immediately after the simulation, a significant increase in medical knowledge was recorded but was higher in the AP-O group (6 [5-8] to 10 [8-11]/16) than in the O group (7 [5-8] to 9 [7-10]/16). High scores for non-technical skills were similarly observed in both groups. Satisfaction was high in both groups but was higher in the AP-O group (9 [8-9] versus 8 [8-9]/10, P=0.019). Decay of knowledge was observed for most main outcomes at three months. This study suggests an immediate improvement of learning outcomes for both roles after immersive simulation but some learning outcomes may be better for residents engaged as players in scenarios. Copyright © 2018. Published by Elsevier Masson SAS.

  9. Single-dose Intravenous Toxicology Testing of Daebohwalryeok Pharmcopuncture in Sprague-Dawley Rats.

    Science.gov (United States)

    Sun, Seung-Ho; Park, Sunju; Jeong, Jong-Jin; Lee, Kwang-Ho; Yu, Jun-Sang; Seo, Hyung-Sik; Kwon, Ki-Rok

    2015-06-01

    The aims of the study were to test the single-dose intravenous toxicity of Daebohwalryeok pharmacopuncture (DHRP) in Sprague-Dawley (SD) rats and to estimate the crude lethal dose. The experiments were conducted at Biotoxtech Co., a Good Laboratory Practice (GLP) laboratory, according to the GLP regulation and were approved by the Institutional Animal Care and Use Committee of Biotoxtech Co. (Approval no: 110156). The rats were divided into three groups: DHRP was injected into the rats in the two test groups at doses of 10 mL/kg and 20 mL/kg, respectively, and normal saline solution was injected into the rats in the control group. Single doses of DHRP were injected intravenously into 6 week old SD rats (5 male and 5 female rats per group). General symptoms were observed and weights were measured during the 14 day observation period after the injection. After the observation period, necropsies were done. Then, histopathological tests were performed. Weight data were analyzed with a one-way analysis of variance (ANOVA) by using statistical analysis system (SAS, version 9.2). No deaths and no statistical significant weight changes were observed for either male or female SD rats in either the control or the test groups during the observation period. In addition, no treatment related general symptoms or necropsy abnormalities were observed. Histopathological results showed no DHRP related effects in the 20 mL/kg DHRP group for either male or female rats. Under the conditions of this study, the results from single-dose intravenous injections of DHRP showed that estimated lethal doses for both male and female rats were above 20 mL/kg.

  10. Single-dose Intravenous Toxicology Testing of Daebohwalryeok Pharmcopuncture in Sprague-Dawley Rats

    Directory of Open Access Journals (Sweden)

    Seung-Ho Sun

    2015-06-01

    Full Text Available Objectives: The aims of the study were to test the single-dose intravenous toxicity of Daebohwalryeok pharmacopuncture (DHRP in Sprague-Dawley (SD rats and to estimate the crude lethal dose. Methods: The experiments were conducted at Biotoxtech Co., a Good Laboratory Practice (GLP laboratory, according to the GLP regulation and were approved by the Institutional Animal Care and Use Committee of Biotoxtech Co. (Approval no: 110156. The rats were divided into three groups: DHRP was injected into the rats in the two test groups at doses of 10 mL/kg and 20 mL/kg, respectively, and normal saline solution was injected into the rats in the control group. Single doses of DHRP were injected intravenously into 6 week old SD rats (5 male and 5 female rats per group. General symptoms were observed and weights were measured during the 14 day observation period after the injection. After the observation period, necropsies were done. Then, histopathological tests were performed. Weight data were analyzed with a one-way analysis of variance (ANOVA by using statistical analysis system (SAS, version 9.2. Results: No deaths and no statistical significant weight changes were observed for either male or female SD rats in either the control or the test groups during the observation period. In addition, no treatment related general symptoms or necropsy abnormalities were observed. Histopathological results showed no DHRP related effects in the 20 mL/kg DHRP group for either male or female rats. Conclusion: Under the conditions of this study, the results from single-dose intravenous injections of DHRP showed that estimated lethal doses for both male and female rats were above 20 mL/kg.

  11. Are single-well "push-pull" tests suitable tracer methods for aquifer characterization?

    Science.gov (United States)

    Hebig, Klaus; Zeilfelder, Sarah; Ito, Narimitsu; Machida, Isao; Scheytt, Traugott; Marui, Atsunao

    2013-04-01

    Recently, investigations were conducted for geological and hydrogeological characterisation of the sedimentary coastal basin of Horonobe (Hokkaido, Japan). Coastal areas are typical geological settings in Japan, which are less tectonically active than the mountain ranges. In Asia, and especially in Japan, these areas are often densely populated. Therefore, it is important to investigate the behaviour of solutes in such unconsolidated aquifers. In such settings sometimes only single boreholes or groundwater monitoring wells are available for aquifer testing for various reasons, e.g. depths of more than 100 m below ground level and slow groundwater velocities due to density driven flow. A standard tracer test with several involved groundwater monitoring wells is generally very difficult or even not possible at these depths. One of the most important questions in our project was how we can obtain information about chemical and hydraulic properties in such aquifers. Is it possible to characterize solute transport behaviour parameters with only one available groundwater monitoring well or borehole? A so-called "push-pull" test may be one suitable method for aquifer testing with only one available access point. In a push-pull test a known amount of several solutes including a conservative tracer is injected into the aquifer ("push") and afterwards extracted ("pull"). The measured breakthrough curve during the pumping back phase can then be analysed. This method has already been used previously with various aims, also in the recent project (e.g. Hebig et al. 2011, Zeilfelder et al. 2012). However, different test setups produced different tracer breakthrough curves. As no systematic evaluation of this aquifer tracer test method was done so far, nothing is known about its repeatability. Does the injection and extraction rate influence the shape of the breakthrough curve? Which role plays the often applied "chaser", which is used to push the test solution out from the

  12. Firefly Optimization and Mathematical Modeling of a Vehicle Crash Test Based on Single-Mass

    Directory of Open Access Journals (Sweden)

    Andreas Klausen

    2014-01-01

    Full Text Available In this paper mathematical modeling of a vehicle crash test based on a single-mass is studied. The model under consideration consists of a single-mass coupled with a spring and/or a damper. The parameters for the spring and damper are obtained by analyzing the measured acceleration in the center of gravity of the vehicle during a crash. A model with a nonlinear spring and damper is also proposed and the parameters will be optimized with different damper and spring characteristics and optimization algorithms. The optimization algorithms used are interior-point and firefly algorithm. The objective of this paper is to compare different methods used to establish a simple model of a car crash and validate the results against real crash data.

  13. Single-Event Effect Testing of the Linear Technology LTC6103HMS8#PBF Current Sense Amplifier

    Science.gov (United States)

    Yau, Ka-Yen; Campola, Michael J.; Wilcox, Edward

    2016-01-01

    The LTC6103HMS8#PBF (henceforth abbreviated as LTC6103) current sense amplifier from Linear Technology was tested for both destructive and non-destructive single-event effects (SEE) using the heavy-ion cyclotron accelerator beam at Lawrence Berkeley National Laboratory (LBNL) Berkeley Accelerator Effects (BASE) facility. During testing, the input voltages and output currents were monitored to detect single event latch-up (SEL) and single-event transients (SETs).

  14. Fractal and Morphological Characteristics of Single Marble Particle Crushing in Uniaxial Compression Tests

    Directory of Open Access Journals (Sweden)

    Yidong Wang

    2015-01-01

    Full Text Available Crushing of rock particles is a phenomenon commonly encountered in geotechnical engineering practice. It is however difficult to study the crushing of rock particles using classical theory because the physical structure of the particles is complex and irregular. This paper aims at evaluating fractal and morphological characteristics of single rock particle. A large number of particle crushing tests are conducted on single rock particle. The force-displacement curves and the particle size distributions (PSD of crushed particles are analysed based on particle crushing tests. Particle shape plays an important role in both the micro- and macroscale responses of a granular assembly. The PSD of an assortment of rocks are analysed by fractal methods, and the fractal dimension is obtained. A theoretical formula for particle crushing strength is derived, utilising the fractal model, and a simple method is proposed for predicting the probability of particle survival based on the Weibull statistics. Based on a few physical assumptions, simple equations are derived for determining particle crushing energy. The results of applying these equations are tested against the actual experimental data and prove to be very consistent. Fractal theory is therefore applicable for analysis of particle crushing.

  15. Tidal Volume Single Breath Washout of Two Tracer Gases - A Practical and Promising Lung Function Test

    Science.gov (United States)

    Singer, Florian; Stern, Georgette; Thamrin, Cindy; Fuchs, Oliver; Riedel, Thomas; Gustafsson, Per; Frey, Urs; Latzin, Philipp

    2011-01-01

    Background Small airway disease frequently occurs in chronic lung diseases and may cause ventilation inhomogeneity (VI), which can be assessed by washout tests of inert tracer gas. Using two tracer gases with unequal molar mass (MM) and diffusivity increases specificity for VI in different lung zones. Currently washout tests are underutilised due to the time and effort required for measurements. The aim of this study was to develop and validate a simple technique for a new tidal single breath washout test (SBW) of sulfur hexafluoride (SF6) and helium (He) using an ultrasonic flowmeter (USFM). Methods The tracer gas mixture contained 5% SF6 and 26.3% He, had similar total MM as air, and was applied for a single tidal breath in 13 healthy adults. The USFM measured MM, which was then plotted against expired volume. USFM and mass spectrometer signals were compared in six subjects performing three SBW. Repeatability and reproducibility of SBW, i.e., area under the MM curve (AUC), were determined in seven subjects performing three SBW 24 hours apart. Results USFM reliably measured MM during all SBW tests (n = 60). MM from USFM reflected SF6 and He washout patterns measured by mass spectrometer. USFM signals were highly associated with mass spectrometer signals, e.g., for MM, linear regression r-squared was 0.98. Intra-subject coefficient of variation of AUC was 6.8%, and coefficient of repeatability was 11.8%. Conclusion The USFM accurately measured relative changes in SF6 and He washout. SBW tests were repeatable and reproducible in healthy adults. We have developed a fast, reliable, and straightforward USFM based SBW method, which provides valid information on SF6 and He washout patterns during tidal breathing. PMID:21423739

  16. Third session: new projects

    International Nuclear Information System (INIS)

    Iracane, D.; Dupuy, J.P.; Perotto, G.; Ithurralde, G.; Cabrillat, J.C.; Becle, D.; Pivet, S.; Minguet, J.L.

    2005-01-01

    The RJH (Jules Horowitz reactor) is a 100 MWth research reactor, cooled and moderated by water, that has been designed to operate with high density (8 g U/cm 3 ) and low enrichment fuel (19.75%) uranium molybdenum fuel. Its main neutron performances are expected to be: -) maximum fast neutron flux (E > 0.907 MeV) in the sample: 5.10 14 n/cm 2 /s, -) maximum thermal neutron flux (E 14 n/cm 2 /s, and -) maximal neutron damage: 16 dpa/year. RJH that will be built on the Cea's site of Cadarache, is scheduled to enter into service in 2014, it will take over the activities of the Osiris reactor and its operating life is planned to be over 50 years long. The Cabri research reactor is located on the Cadarache site, it has been operating since 1962 and is now undergoing important upgrading operations whose aim is to make the facility fit to study the behaviour of new nuclear fuels in accidental situations. The RES test reactor is a facility whose aim is to qualify nuclear fuels and core configurations of existing propulsion reactors onboard of aircraft carriers or submarines and to propose innovative concepts for future propulsion reactors. (A.C.)

  17. Summary of Group Development and Testing for Single Shell Tank Closure at Hanford

    Energy Technology Data Exchange (ETDEWEB)

    Harbour, John, R.

    2005-04-28

    This report is a summary of the bench-scale and large scale experimental studies performed by Savannah River National Laboratory for CH2M HILL to develop grout design mixes for possible use in producing fill materials as a part of Tank Closure of the Single-Shell Tanks at Hanford. The grout development data provided in this report demonstrates that these design mixes will produce fill materials that are ready for use in Hanford single shell tank closure. The purpose of this report is to assess the ability of the proposed grout specifications to meet the current requirements for successful single shell tank closure which will include the contracting of services for construction and operation of a grout batch plant. The research and field experience gained by SRNL in the closure of Tanks 17F and 20F at the Savannah River Site was leveraged into the grout development efforts for Hanford. It is concluded that the three Hanford grout design mixes provide fill materials that meet the current requirements for successful placement. This conclusion is based on the completion of recommended testing using Hanford area materials by the operators of the grout batch plant. This report summarizes the regulatory drivers and the requirements for grout mixes as tank fill material. It is these requirements for both fresh and cured grout properties that drove the development of the grout formulations for the stabilization, structural and capping layers.

  18. Experimental study on the single event effects in pulse width modulators by laser testing

    International Nuclear Information System (INIS)

    Zhao Wen; Guo Xiaoqiang; Chen Wei; Guo Hongxia; Lin Dongsheng; Luo Yinhong; Ding Lili; Wang Yuanming; Wang Hanning

    2015-01-01

    This paper presents single event effect (SEE) characteristics of UC1845AJ pulse width modulators (PWMs) by laser testing. In combination with analysis to map PWM circuitry in the microchip dies, the typical SEE response waveforms for laser pulses located in different circuit blocks of UC1845AJ are obtained and the SEE mechanisms are analyzed. The laser SEE test results show that there are some differences in the SEE mechanisms of different circuit blocks, and phase shifts or changes in the duty cycles of few output pulses are the main SEE behaviors for UC1845AJ. In addition, a new SEE behavior which manifests as changes in the duty cycles of many output pulses is revealed. This means that an SEE hardened design should be considered. (paper)

  19. Evaluation of canine adverse food reactions by patch testing with single proteins, single carbohydrates and commercial foods.

    Science.gov (United States)

    Johansen, Cornelia; Mariani, Claire; Mueller, Ralf S

    2017-10-01

    Adverse food reaction (AFR) is an important differential diagnosis for the pruritic dog. It is usually diagnosed by feeding an elimination diet with a novel protein and carbohydrate source for eight weeks followed by subsequent food provocation. A previous study demonstrated that patch testing dogs with foods had a high sensitivity and negative predictability for selection of elimination diet ingredients. The aim of this study was to investigate patch testing with proteins, carbohydrates and dry commercial dog food in dogs to determine whether there was value in patch testing to aid the diagnosis of canine adverse food reaction. Twenty five privately owned dogs, with confirmed AFR, underwent provocation trials with selected food antigens and patch testing. For proteins, carbohydrates and dry dog food the sensitivity of patch testing was 100%, 70% and 22.2%, respectively; the negative predictive values of patch testing were 100%, 79% and 72%. The positive predictive values of patch testing for proteins and carbohydrates were 75% and 74%, respectively. This study confirmed that patch testing may be useful for the selection of a suitable protein source for an elimination diet in dogs with suspected AFR, but not as a diagnostic tool for canine AFR. Results for proteins are more reliable than for carbohydrates and the majority of positive patch test reactions were observed with raw protein. Patch testing with commercial dog food does not seem to be useful. © 2017 ESVD and ACVD.

  20. Design of a single-borehole hydraulic test programme allowing for interpretation-based errors

    International Nuclear Information System (INIS)

    Black, J.H.

    1987-07-01

    Hydraulic testing using packers in single boreholes is one of the most important sources of data to safety assessment modelling in connection with the disposal of radioactive waste. It is also one of the most time-consuming and expensive. It is important that the results are as reliable as possible and as accurate as necessary for the use that is made of them. There are many causes of possible error and inaccuracy ranging from poor field practice to inappropriate interpretation procedure. The report examines and attempts to quantify the size of error arising from the accidental use of an inappropriate or inadequate interpretation procedure. In doing so, it can be seen which interpretation procedure or combination of procedures results in least error. Lastly, the report attempts to use the previous conclusions from interpretation to propose forms of field test procedure where interpretation-based errors will be minimised. Hydraulic tests (sometimes known as packer tests) come in three basic forms: slug/pulse, constant flow and constant head. They have different characteristics, some measuring a variable volume of rock (dependent on hydraulic conductivity) and some having a variable duration (dependent on hydraulic conductivity). A combination of different tests in the same interval is seen as desirable. For the purposes of assessing interpretation-based errors, slug and pulse tests are considered together as are constant flow and constant head tests. The same method is used in each case to assess errors. The method assumes that the simplest analysis procedure (cylindrical flow in homogeneous isotropic porous rock) will be used on each set of field data. The error is assessed by calculating synthetic data for alternative configurations (e.g. fissured rock, anisotropic rock, inhomogeneous rock - i.e. skin - etc.) and then analyzing this data using the simplest analysis procedure. 28 refs., 26 figs

  1. SRAM single event upset calculation and test using protons in the secondary beam in the BEPC

    Energy Technology Data Exchange (ETDEWEB)

    Wang Yuanming; Guo Hongxia; Zhang Fengqi; Zhang Keying; Chen Wei; Luo Yinhong; Guo Xiaoqiang, E-mail: wangym2007@gmail.com [Northwest Institute of Nuclear Technology, Xi' an 710024 (China)

    2011-09-15

    The protons in the secondary beam in the Beijing Electron Positron Collider (BEPC) are first analyzed and a large proportion at the energy of 50-100 MeV supply a source gap of high energy protons. In this study, the proton energy spectrum of the secondary beam was obtained and a model for calculating the proton single event upset (SEU) cross section of a static random access memory (SRAM) cell has been presented in the BEPC secondary beam proton radiation environment. The proton SEU cross section for different characteristic dimensions has been calculated. The test of SRAM SEU cross sections has been designed, and a good linear relation between SEUs in SRAM and the fluence was found, which is evidence that an SEU has taken place in the SRAM. The SEU cross sections were measured in SRAM with different dimensions. The test result shows that the SEU cross section per bit will decrease with the decrease of the characteristic dimensions of the device, while the total SEU cross section still increases upon the increase of device capacity. The test data accords with the calculation results, so the high-energy proton SEU test on the proton beam in the BEPC secondary beam could be conducted. (semiconductor physics)

  2. The effects of A single dose of gamma-rays applied on the head on behavior of rats in Morris's water maze and in the open field test

    International Nuclear Information System (INIS)

    Smajda, B.; Kiskova, J.; Lievajova, K.; Capicikova, M.

    2006-01-01

    The effects of a sublethal dose of gamma-rays applied on the head on selected behavioral parameters were investigated in this study. Adult male Sprague-Dowley rats (n=9) were irradiated with a single dose of 20 Gy of gamma-rays from a 60 Co radiation source. The irradiated animals as well as sham-irradiated controls were tested daily in Morris water maze (MWM) (2 sessions per day) and in the open field test. The ability of spatial learning given by latency time to find the hidden platform was followed in MWM. The horizontal and vertical locomotion, the number of crossings of the center of the field and the washing behavior were recorded during an 8-minute test in the open field. The results obtained show, that radiation didn't altered significantly the dynamic of learning in MWM during the experiment. The level of horizontal and vertical locomotory activity in open field was lower in irradiated group in comparison with controls. The number of the crossings of the field's center, related to the level of anxiozity of animals was non-significantly lower in irradiated animals, whereas no differences in number of washing between both groups were detected. The results point to differences in radiosensitivity in various behavioral parameters in rats, maybe due to different level of their control and coordination in CNS. (authors)

  3. Single-well push-pull test in transient Forchheimer flow field

    Science.gov (United States)

    Wang, Quanrong; Zhan, Hongbin; Wang, Yanxin

    2017-06-01

    Using the single-well push-pull (SWPP) test to quantify in situ aquifer characteristics associated with solute transport (dispersion coefficient, geobiochemical reaction rates), the accuracy of parameter estimation was not only dependent on the solute transport models but also the groundwater flow models. However, many previous studies on the SWPP test were based on assumptions over-simplifying the flow field, namely, groundwater flow followed Darcy's law; flow was in the steady state during the entire test duration; the wellbore storage could be negligible. In this study, we have carefully examined such assumptions by developing a new finite-difference model of the SWPP test under the transient Forchheimer flow condition, considering the wellbore storage. The SWPP test included an injection phase, a chaser phase, a rest phase, and an extraction phase. The results showed that the concentration of the steady-state flow solution was greater than that of the transient flow solution at the beginning, and its peak value was also greater than that of the transient flow solution. The difference between the breakthrough curves (BTCs) of the transient flow SWPP model and the steady-state flow SWPP model was not negligible, and such a difference increased with the decreasing specific storage. We also found that BTCs were not sensitive to the inertial force coefficient, while they were sensitive to the wellbore storage. BTCs with different radius of the wellbore (rw) were clearly different from each other, and a larger rw resulted in a greater concentration at the well during the extraction phase.

  4. Human Reliability Analysis: session summary

    International Nuclear Information System (INIS)

    Hall, R.E.

    1985-01-01

    The use of Human Reliability Analysis (HRA) to identify and resolve human factors issues has significantly increased over the past two years. Today, utilities, research institutions, consulting firms, and the regulatory agency have found a common application of HRA tools and Probabilistic Risk Assessment (PRA). The ''1985 IEEE Third Conference on Human Factors and Power Plants'' devoted three sessions to the discussion of these applications and a review of the insights so gained. This paper summarizes the three sessions and presents those common conclusions that were discussed during the meeting. The paper concludes that session participants supported the use of an adequately documented ''living PRA'' to address human factors issues in design and procedural changes, regulatory compliance, and training and that the techniques can produce cost effective qualitative results that are complementary to more classical human factors methods

  5. Crash tests of four identical high-wing single-engine airplanes

    Science.gov (United States)

    Vaughan, V. L., Jr.; Hayduk, R. J.

    1980-01-01

    Four identical four place, high wing, single engine airplane specimens with nominal masses of 1043 kg were crash tested at the Langley Impact Dynamics Research Facility under controlled free flight conditions. These tests were conducted with nominal velocities of 25 m/sec along the flight path angles, ground contact pitch angles, and roll angles. Three of the airplane specimens were crashed on a concrete surface; one was crashed on soil. Crash tests revealed that on a hard landing, the main landing gear absorbed about twice the energy for which the gear was designed but sprang back, tending to tip the airplane up to its nose. On concrete surfaces, the airplane impacted and remained in the impact attitude. On soil, the airplane flipped over on its back. The crash impact on the nose of the airplane, whether on soil or concrete, caused massive structural crushing of the forward fuselage. The liveable volume was maintained in both the hard landing and the nose down specimens but was not maintained in the roll impact and nose down on soil specimens.

  6. Additive Manufacturing Thermal Performance Testing of Single Channel GRCop-84 SLM Components

    Science.gov (United States)

    Garcia, Chance P.; Cross, Matthew

    2014-01-01

    The surface finish found on components manufactured by sinter laser manufacturing (SLM) is rougher (0.013 - 0.0006 inches) than parts made using traditional fabrication methods. Internal features and passages built into SLM components do not readily allow for roughness reduction processes. Alternatively, engineering literature suggests that the roughness of a surface can enhance thermal performance within a pressure drop regime. To further investigate the thermal performance of SLM fabricated pieces, several GRCop-84 SLM single channel components were tested using a thermal conduction rig at MSFC. A 20 kW power source running at 25% duty cycle and 25% power level applied heat to each component while varying water flow rates between 2.1 - 6.2 gallons/min (GPM) at a supply pressure of 550 to 700 psi. Each test was allowed to reach quasi-steady state conditions where pressure, temperature, and thermal imaging data were recorded. Presented in this work are the heat transfer responses compared to a traditional machined OHFC Copper test section. An analytical thermal model was constructed to anchor theoretical models with the empirical data.

  7. A single sample GnRHa stimulation test in the diagnosis of precocious puberty

    Directory of Open Access Journals (Sweden)

    Yazdani Parvin

    2012-07-01

    Full Text Available Abstract Context Gonadotropin-releasing hormone (GnRH has been the standard test for diagnosing central precocious puberty. Because GnRH is no longer available, GnRH analogues (GnRHa are now used. Random LH concentration, measured by the third-generation immunochemiluminometric assay, is a useful screening tool for central precocious puberty. However, GnRHa stimulation test should be considered, when a basal LH measurement is inconclusive. However optimal sampling times for luteinizing hormone (LH have yet to be established. Purpose To determine the appropriate sampling time for LH post leuprolide challenge. Methods A retrospective analysis of multi-sample GnRHa stimulation tests performed in 155 children (aged 1–9 years referred for precocious puberty to Texas Children’s Hospital. After 20 mcg/kg of SQ leuprolide acetate, samples were obtained at 0, 1, 3, and 6 hours. Results Of 71 children with clinical evidence of central precocious puberty, fifty nine children had a peak LH >5 mIU/mL. 52 (88% of these responders had positive responses at 1 hour (95% CI is 80–96%, whereas all 59 children (100% had a peak LH response >5 mIU/mL at 3 hours (95% CI is 94-100%, P = 0.005. Conclusions A single serum LH sample collected 3 hours post GnRHa challenge is the optimal sample to establish the diagnosis of central precocious puberty.

  8. First indirect x-ray imaging tests with an 88-mm diameter single crystal

    Energy Technology Data Exchange (ETDEWEB)

    Lumpkin, A. H. [Fermilab; Macrander, A. T. [Argonne

    2017-02-01

    Using the 1-BM-C beamline at the Advanced Photon Source (APS), we have performed the initial indirect x - ray imaging point-spread-function (PSF) test of a unique 88-mm diameter YAG:Ce single crystal of only 100 - micron thickness. The crystal was bonded to a fiber optic plat e (FOP) for mechanical support and to allow the option for FO coupling to a large format camera. This configuration resolution was compared to that of self - supported 25-mm diameter crystals, with and without an Al reflective coating. An upstream monochromator was used to select 17-keV x-rays from the broadband APS bending magnet source of synchrotron radiation. The upstream , adjustable Mo collimators were then used to provide a series of x-ray source transverse sizes from 200 microns down to about 15-20 microns (FWHM) at the crystal surface. The emitted scintillator radiation was in this case lens coupled to the ANDOR Neo sCMOS camera, and the indirect x-ray images were processed offline by a MATLAB - based image processing program. Based on single Gaussian peak fits to the x-ray image projected profiles, we observed a 10.5 micron PSF. This sample thus exhibited superior spatial resolution to standard P43 polycrystalline phosphors of the same thickness which would have about a 100-micron PSF. Lastly, this single crystal resolution combined with the 88-mm diameter makes it a candidate to support future x-ray diffraction or wafer topography experiments.

  9. NASA Electronic Parts and Packaging (NEPP) Field Programmable Gate Array (FPGA) Single Event Effects (SEE) Test Guideline Update

    Science.gov (United States)

    Berg, Melanie D.; LaBel, Kenneth A.

    2018-01-01

    The following are updated or new subjects added to the FPGA SEE Test Guidelines manual: academic versus mission specific device evaluation, single event latch-up (SEL) test and analysis, SEE response visibility enhancement during radiation testing, mitigation evaluation (embedded and user-implemented), unreliable design and its affects to SEE Data, testing flushable architectures versus non-flushable architectures, intellectual property core (IP Core) test and evaluation (addresses embedded and user-inserted), heavy-ion energy and linear energy transfer (LET) selection, proton versus heavy-ion testing, fault injection, mean fluence to failure analysis, and mission specific system-level single event upset (SEU) response prediction. Most sections within the guidelines manual provide information regarding best practices for test structure and test system development. The scope of this manual addresses academic versus mission specific device evaluation and visibility enhancement in IP Core testing.

  10. Test of a single module of the J-PET scanner based on plastic scintillators

    Science.gov (United States)

    Moskal, P.; Niedźwiecki, Sz.; Bednarski, T.; Czerwiński, E.; Kapłon, Ł.; Kubicz, E.; Moskal, I.; Pawlik-Niedźwiecka, M.; Sharma, N. G.; Silarski, M.; Zieliński, M.; Zoń, N.; Białas, P.; Gajos, A.; Kochanowski, A.; Korcyl, G.; Kowal, J.; Kowalski, P.; Kozik, T.; Krzemień, W.; Molenda, M.; Pałka, M.; Raczyński, L.; Rudy, Z.; Salabura, P.; Słomski, A.; Smyrski, J.; Strzelecki, A.; Wieczorek, A.; Wiślicki, W.

    2014-11-01

    A Time of Flight Positron Emission Tomography scanner based on plastic scintillators is being developed at the Jagiellonian University by the J-PET collaboration. The main challenge of the conducted research lies in the elaboration of a method allowing application of plastic scintillators for the detection of low energy gamma quanta. In this paper we report on tests of a single detection module built out from the BC-420 plastic scintillator strip (with dimensions of 5×19×300 mm3) read out at two ends by Hamamatsu R5320 photomultipliers. The measurements were performed using collimated beam of annihilation quanta from the 68Ge isotope and applying the Serial Data Analyzer (Lecroy SDA6000A) which enabled sampling of signals with 50 ps intervals. The time resolution of the prototype module was established to be better than 80 ps (σ) for a single level discrimination. The spatial resolution of the determination of the hit position along the strip was determined to be about 0.93 cm (σ) for the annihilation quanta. The fractional energy resolution for the energy E deposited by the annihilation quanta via the Compton scattering amounts to σ(E) / E ≈ 0.044 /√{ E(MeV) } and corresponds to the σ(E) / E of 7.5% at the Compton edge.

  11. Compendium of Single-Event Latchup and Total Ionizing Dose Test Results of Commercial Analog to Digital Converters

    Science.gov (United States)

    Irom, Farokh; Agarwal, Shri G.

    2012-01-01

    This paper reports single-event latchup and total dose results for a variety of analog to digital converters targeted for possible use in NASA spacecraft's. The compendium covers devices tested over the last 15 years.

  12. Single test isolated lupus anticoagulant positivity is associated with increased plasma levels of inflammatory markers and dyslipidemia

    DEFF Research Database (Denmark)

    Just, S A; Nybo, M; Laustrup, H

    2016-01-01

    OBJECTIVE: To investigate whether a single positive test for lupus anticoagulant (LA) is associated with levels of inflammatory markers and traditional cardiovascular risk factors, independent of autoimmune disease, thrombophilia and occurrence of other antiphospholipid antibodies. METHODS: In a ...

  13. Single-well tracer push-pull test sensitivity w. r. to fracture aperture and spacing

    Science.gov (United States)

    Ghergut, I.; Behrens, H.; Karmakar, S.; Sauter, M.

    2012-04-01

    Dealing with a parallel-fracture system of infinite lateral extension, four characteristic regimes of tracer signal sensitivity w. r. to fracture aperture and w. r. to fracture spacing s (whose reciprocal defines fracture density, or the fluid-rock interface area per volume) can be identified during the pull phase of a single-well push-pull test, also depending upon the ratio between push-phase duration Tpush and a characteristic time scale Ts (defined by s2 / D = Ts , with D denoting the tracer's effective diffusion coefficient): early-time regime: tracer signals are sensitive w. r. to fracture aperture, but insensitive w. r. to fracture spacing; sensitivity w. r. to fracture aperture first increases, then decreases with Tpush / Ts (thus there will be an optimum in terms of to Tpush / Ts , at early pull times); mid-time regime: tracer signals are sensitive w. r. to fracture spacing, but insensitive w. r. to fracture aperture; sensitivity w. r. to fracture spacing increases with Tpush / Ts ; late-time regime: with increasing pull duration, tracer signals become increasingly insensitive w. r. to fracture spacing, while regaining sensitivity w. r. to fracture aperture; 'very late'-time regime: sensitivity w. r. to fracture aperture becomes independent upon Tpush / Ts . From these different regimes, some recommendations can be derived regarding the design and dimensioning of dual-tracer single-well push-pull tests for the specific purposes of geothermal reservoir characterization, using conservative solutes and heat as tracers. Acknowledgement: This study is funded by MWK Niedersachsen (Lower-Saxony's Science and Culture Ministry) and by Baker Hughes (Celle) within task unit 'G6' of the Collaborative Research Project 'gebo' (Geothermal Energy and High-Performance Drilling).

  14. Definition of Capabilities Needed for a Single Event Effects Test Facility

    Energy Technology Data Exchange (ETDEWEB)

    Riemer, Bernie [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States). Spallation Neutron Source (SNS); Gallmeier, Franz X. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States). Spallation Neutron Source (SNS)

    2014-12-01

    The Federal Aviation Administration (FAA) is contemplating new regulations mandating testing of the vulnerability of flight-critical avionics to single event effects (SEE). A limited number of high-energy neutron test facilities currently serve the SEE industrial and institutional research community. The FAA recognizes that existing facilities have insufficient test capacity to meet new demand from such mandates; it desires more flexible irradiation capabilities to test complete, large systems and would like capabilities to address greater concerns for thermal neutrons. For this reason, the FAA funded this study by Spallation Neutron Source (SNS) staff with the ultimate aim of developing options for SEE test facilities using high-energy neutrons at the SNS complex. After an investigation of current SEE test practices and assessment of future testing requirements, three concepts were identified covering a range of test functionality, neutron flux levels, and fidelity to the atmospheric neutron spectrum. The costs and times required to complete each facility were also estimated. SEE testing is generally performed by accelerating the event rate to a point where the effects are still dominated by single events and double event causes of failures are negligible. In practice, acceleration factors of as high as 106 are applicable for component testing, whereas for systems testing acceleration factors of 104 seem to be the upper limit. It is strongly desirable that the irradiation facility be tunable over a large range of high-energy neutron fluxes of 102 - 104 n/cm²/s for systems testing and from 104 - 107 n/cm²/s for components testing. The most capable, most flexible, and highest-test-capacity option is a new stand-alone target station named the High-Energy neutron Test Station (HETS). It is also the most expensive option, with a cost to complete of approximately $100 million. Dual test enclosures would

  15. Sessions and Separability in Security Protocols

    DEFF Research Database (Denmark)

    Carbone, Marco; Guttman, Joshua

    2013-01-01

    Despite much work on sessions and session types in non- adversarial contexts, session-like behavior given an active adversary has not received an adequate definition and proof methods. We provide a syntactic property that guarantees that a protocol has session-respecting executions. Any uncomprom......Despite much work on sessions and session types in non- adversarial contexts, session-like behavior given an active adversary has not received an adequate definition and proof methods. We provide a syntactic property that guarantees that a protocol has session-respecting executions. Any...

  16. Single-Event Effect Testing of the Cree C4D40120D Commercial 1200V Silicon Carbide Schottky Diode

    Science.gov (United States)

    Lauenstein, J.-M.; Casey, M. C.; Wilcox, E. P.; Kim, Hak; Topper, A. D.

    2014-01-01

    This study was undertaken to determine the single event effect (SEE) susceptibility of the commercial silicon carbide 1200V Schottky diode manufactured by Cree, Inc. Heavy-ion testing was conducted at the Texas A&M University Cyclotron Single Event Effects Test Facility (TAMU). Its purpose was to evaluate this device as a candidate for use in the Solar-Electric Propulsion flight project.

  17. Conditioning geostatistical simulations of a bedrock fluvial aquifer using single well pumping tests

    Science.gov (United States)

    Niazi, A.; Bentley, L. R.; Hayashi, M.

    2015-12-01

    Geostatistical simulation is a powerful tool to explore the uncertainty associated with heterogeneity in groundwater and reservoir studies. Nonetheless, conditioning simulations merely with lithological information does not utilize all of the available information and so some workers additionally condition simulations with flow data. In this study, we introduce an approach to condition geostatistical simulations of the Paskapoo Formation, which is a paleo-fluvial system consisting of sandstone channels embedded in mudstone. The conditioning data consist of two-hour single well pumping tests extracted from the public water well database in Alberta, Canada. In this approach, lithologic models of an entire watershed are simulated and conditioned with hard lithological data using transition probability geostatistics (TPROGS). Then, a segment of the simulation around a pumping well was used to populate a flow model (FEFLOW) with either sand or mudstone. The values of the hydraulic conductivity and specific storage of sand and mudstone were then adjusted to minimize the difference between simulated and actual pumping test data using the parameter estimation program PEST. If the simulated data do not adequately match the measured data, the lithologic model is updated by locally deforming the lithology distribution using the probability perturbation method (PPM) and the model parameters are again updated with PEST. This procedure is repeated until the simulated and measured data agree within a pre-determined tolerance. The procedure is repeated for each pumping well that has pumping test data. The method constrains the lithological simulations and provides estimates of hydraulic conductivity and specific storage that are consistent with the pumping test data. Eventually, the simulations will be combined in watershed scale groundwater models.

  18. Results of single borehole hydraulic tests in the Mizunami Underground Research Laboratory project. FY 2012 - FY 2015

    International Nuclear Information System (INIS)

    Onoe, Hironori; Takeuchi, Ryuji

    2016-11-01

    This report summarize the results of the single borehole hydraulic tests of 151 sections carried out at the -300 m Stage and the -500 m Stage of the Mizunami Underground Research Laboratory from FY 2012 to FY 2015. The details of each test (test interval depth, geology, etc.) as well as the interpreted hydraulic parameters and analytical methods used are presented in this report. Furthermore, the previous results of the single borehole hydraulic tests carried out in the Regional Hydrogeological Study Project and the Mizunami Underground Research Laboratory Project before FY 2012 are also summarized in this report. (author)

  19. Summary of Educational Poster Session

    Science.gov (United States)

    1992-01-01

    The educational poster session provided a way of increasing the ordinarily limited time available for discussion of papers, while simultaneously making it easier to communicate visual materials not well suited to oral presentations. Poster presenters were available for 3 hours to discuss their displays. Poster presentations were divided into two categories: minority...

  20. After Smokestack Chasing. Plenary Session.

    Science.gov (United States)

    Appalachia, 1986

    1986-01-01

    Plenary session opening remarks by Appalachian Regional Commission Co-Chairman Winnifred Pizzano inform participants that the Region's future success depends on their ability to meet the challenge of change. Excerpts from four panelists' speeches address rapid social and economic changes in economic development activities at state and local…

  1. Teaching statistics to medical undergraduates using interactive and participatory sessions

    Directory of Open Access Journals (Sweden)

    THULASINGAM MAHALAKSHMY

    2013-10-01

    Full Text Available Introduction: In India, medical undergraduates think that statistics is difficult to understand. Often, it is taught just before final assessment examination using didactic lectures, with little use of medical examples and less focus on application. Hence, we prepared interactive, participatory sessions for teaching biostatistics to medical undergraduate. Methods: The sessions were delivered by a facilitator. It had clearly specified objectives and teaching learning strategies. A needs assessment was done by interviewing the students who had undergone traditional biostatistics teaching methodology. Specific learning objectives for the sessions were finalized using the Delphi technique and review of University syllabus. Two trained Community Medicine faculties designed the lesson plans ‘backwards’ from desired outcome to content, teaching/learning strategies, assessment and evaluation process (Outcomes-based lesson planning. Forty, third-semester (Para-clinical phase of the second year medical undergraduates undertook these seven teaching sessions. The session followed adult learning principles and included group discussions, games and reflections. We evaluated the impact of the sessions using in-depth interviews, retrospective post-then-preself- assessment and a pre-announced written test. Results: With traditional statistics teaching methodology, students perceived it as a standalone subject and were not interested in statistics. Students who underwent the sessions commented that the sessions were enjoyable, interesting, and participatory and more than %90 of them felt they were engaged throughout the session. They also narrated various instances where they could apply the biostatistics learning. In the post-then-pre-assessment median post-session scores for all the objectives were significantly higher (p <0.050. Conclusion: Use of interactive, participatory sessions for teaching biostatistics to medical undergraduates resulted in a

  2. ASSERT validation against the Stern Laboratories' single-phase pressure drop tests

    International Nuclear Information System (INIS)

    Waddington, G.M.; Kiteley, J.C.; Carver, M.B.

    1995-01-01

    This paper describes the preliminary validation of ASSERT-IV against the single-phase pressure drop tests from the 37-element CHF (critical heat flux) experiments conducted at Stern Laboratories, and shows how this study fits into the overall ASSERT validation plan. The effects on the pressure drop of several friction and form loss models are evaluated, including the geometry-based K-factor model. The choice of friction factor has a small effect on the predicted channel pressure drop, compared to the form loss model choice. Using the uniform K-factors of Hameed, the computed pressure drops are in excellent agreement with the experimental results from the nominal pressure tube tests. For future ASSERT applications, either Hameed's uniform K-factors or the geometry-based model using Idelchik's thick-edged orifice equation are recommended, as are the friction factor correlations of Colebrook-White, Selander, and Aly and Groeneveld. More analysis of the geometry-based K-factor model is required. (author). 23 refs., 4 tabs., 9 figs

  3. Creep lifing methodologies applied to a single crystal superalloy by use of small scale test techniques

    Energy Technology Data Exchange (ETDEWEB)

    Jeffs, S.P., E-mail: s.p.jeffs@swansea.ac.uk [Institute of Structural Materials, Swansea University, Singleton Park SA2 8PP (United Kingdom); Lancaster, R.J. [Institute of Structural Materials, Swansea University, Singleton Park SA2 8PP (United Kingdom); Garcia, T.E. [IUTA (University Institute of Industrial Technology of Asturias), University of Oviedo, Edificio Departamental Oeste 7.1.17, Campus Universitario, 33203 Gijón (Spain)

    2015-06-11

    In recent years, advances in creep data interpretation have been achieved either by modified Monkman–Grant relationships or through the more contemporary Wilshire equations, which offer the opportunity of predicting long term behaviour extrapolated from short term results. Long term lifing techniques prove extremely useful in creep dominated applications, such as in the power generation industry and in particular nuclear where large static loads are applied, equally a reduction in lead time for new alloy implementation within the industry is critical. The latter requirement brings about the utilisation of the small punch (SP) creep test, a widely recognised approach for obtaining useful mechanical property information from limited material volumes, as is typically the case with novel alloy development and for any in-situ mechanical testing that may be required. The ability to correlate SP creep results with uniaxial data is vital when considering the benefits of the technique. As such an equation has been developed, known as the k{sub SP} method, which has been proven to be an effective tool across several material systems. The current work now explores the application of the aforementioned empirical approaches to correlate small punch creep data obtained on a single crystal superalloy over a range of elevated temperatures. Finite element modelling through ABAQUS software based on the uniaxial creep data has also been implemented to characterise the SP deformation and help corroborate the experimental results.

  4. Estimating transmissivity from single-well pumping tests in heterogeneous aquifers

    Science.gov (United States)

    Pechstein, Armin; Attinger, Sabine; Krieg, Ronald; Copty, Nadim K.

    2016-01-01

    Although aquifers are naturally heterogeneous, the interpretation of pumping tests is commonly performed under the assumption of aquifer homogeneity. This yields interpreted hydraulic parameters averaged over a domain of uncertain extent which disguises their relation to the underlying heterogeneity. In this study, we numerically investigate the sensitivity of the transient drawdown at the pumping well, to nonuniform distributions of transmissivity in confined aquifers. Frechet kernels and their time derivative are used to estimate two spatially averaged transmissivities, denoted the equivalent and interpreted transmissivity, Teq and Tin, respectively, for the case of single-well pumping tests. Interrelating Teq and Tin is achieved by modeling Tin in terms of a distance dependent, radially heterogeneous field. In weakly heterogeneous aquifers, Teq approximates TPW, the local transmissivity at the pumped well. With increasing degree of heterogeneity, Teq deviates from TPW as pumping propagates. Tin starts at TPW, approaching the spatial geometric mean of transmissivity during late pumping times. Limits of the proposed spatial weighting functions are investigated by treating the interpreted storativity, Sest, as an indicator for flow connectivity. It is shown numerically that the spatial weights for Teq and Tin agree well to the underlying heterogeneity if . Finally, implications for applying the concepts of Teq and Tin to heterogeneous domains, and, for real world applications are discussed. It is found that time-dependent spatial averages of Tin agree well with estimates of the interpreted transmissivity from the Continuous-Derivation method.

  5. Less is more: latent learning is maximized by shorter training sessions in auditory perceptual learning.

    Directory of Open Access Journals (Sweden)

    Katharine Molloy

    Full Text Available The time course and outcome of perceptual learning can be affected by the length and distribution of practice, but the training regimen parameters that govern these effects have received little systematic study in the auditory domain. We asked whether there was a minimum requirement on the number of trials within a training session for learning to occur, whether there was a maximum limit beyond which additional trials became ineffective, and whether multiple training sessions provided benefit over a single session.We investigated the efficacy of different regimens that varied in the distribution of practice across training sessions and in the overall amount of practice received on a frequency discrimination task. While learning was relatively robust to variations in regimen, the group with the shortest training sessions (∼8 min had significantly faster learning in early stages of training than groups with longer sessions. In later stages, the group with the longest training sessions (>1 hr showed slower learning than the other groups, suggesting overtraining. Between-session improvements were inversely correlated with performance; they were largest at the start of training and reduced as training progressed. In a second experiment we found no additional longer-term improvement in performance, retention, or transfer of learning for a group that trained over 4 sessions (∼4 hr in total relative to a group that trained for a single session (∼1 hr. However, the mechanisms of learning differed; the single-session group continued to improve in the days following cessation of training, whereas the multi-session group showed no further improvement once training had ceased.Shorter training sessions were advantageous because they allowed for more latent, between-session and post-training learning to emerge. These findings suggest that efficient regimens should use short training sessions, and optimized spacing between sessions.

  6. Patients' in-session experiences and symptom change: Session-to-session effects on a within- and between-patient level.

    Science.gov (United States)

    Rubel, Julian A; Rosenbaum, David; Lutz, Wolfgang

    2017-03-01

    Knowledge of patients' in-session experiences that lead to symptom change in psychotherapy is limited. This study aims to investigate the within- and between-patient relationships between three in-session processes in psychotherapy (coping skills, therapeutic relationship quality, and emotional involvement) and symptom change on a session-by-session level. Participants (n = 1550) with various disorders, including primarily depression and anxiety, were treated with CBT in a German outpatient clinic. Symptom distress was assessed before each session and patients' in-session experiences were assessed at the end of each session using session reports. Person-mean centering was applied to disaggregate within- and between-patients. Within- and between-patient process scores were tested in multilevel models as predictors of next session symptom change. On a within-patient level, better session-specific coping skills, better therapeutic alliance, and deeper emotional involvement were followed by next session symptom improvements. In a combined model, only coping skills specifically predicted next session symptom change. Additionally, these coping skills were especially helpful when combined with a better therapeutic relationship quality. On a between-patient level, better therapeutic alliance and more coping skills were associated with lower symptom scores during treatment, while deeper emotional involvement was associated with higher symptom scores. Testing these between-patient effects in a combined model left only coping skills (the more, the greater symptom improvement) and emotional involvement (the deeper, the less symptom improvement) as significant predictors. These two also exhibited a combined effect on symptom change on the between-patient level. The results highlight the importance of a thorough disaggregation of within- and between-patient variability in psychotherapy process-outcome research as well as the consideration of several potentially important time

  7. A discrete Single Delay Model for the Intra-Venous Glucose Tolerance Test

    Directory of Open Access Journals (Sweden)

    Panunzi Simona

    2007-09-01

    Full Text Available Abstract Background Due to the increasing importance of identifying insulin resistance, a need exists to have a reliable mathematical model representing the glucose/insulin control system. Such a model should be simple enough to allow precise estimation of insulin sensitivity on a single patient, yet exhibit stable dynamics and reproduce accepted physiological behavior. Results A new, discrete Single Delay Model (SDM of the glucose/insulin system is proposed, applicable to Intra-Venous Glucose Tolerance Tests (IVGTTs as well as to multiple injection and infusion schemes, which is fitted to both glucose and insulin observations simultaneously. The SDM is stable around baseline equilibrium values and has positive bounded solutions at all times. Applying a similar definition as for the Minimal Model (MM SI index, insulin sensitivity is directly represented by the free parameter KxgI of the SDM. In order to assess the reliability of Insulin Sensitivity determinations, both SDM and MM have been fitted to 40 IVGTTs from healthy volunteers. Precision of all parameter estimates is better with the SDM: 40 out of 40 subjects showed identifiable (CV xgI from the SDM, 20 out of 40 having identifiable SI from the MM. KxgI correlates well with the inverse of the HOMA-IR index, while SI correlates only when excluding five subjects with extreme SI values. With the exception of these five subjects, the SDM and MM derived indices correlate very well (r = 0.93. Conclusion The SDM is theoretically sound and practically robust, and can routinely be considered for the determination of insulin sensitivity from the IVGTT. Free software for estimating the SDM parameters is available.

  8. Sessions and Separability in Security Protocols

    DEFF Research Database (Denmark)

    Carbone, Marco; Guttman, Joshua

    2013-01-01

    Despite much work on sessions and session types in non- adversarial contexts, session-like behavior given an active adversary has not received an adequate definition and proof methods. We provide a syntactic property that guarantees that a protocol has session-respecting executions. Any uncomprom...

  9. Single-step brazing process for mono-block joints and mechanical testing

    International Nuclear Information System (INIS)

    Casalegno, V.; Ferraris, M.; Salvo, M.; Rizzo, S.; Merola, M.

    2007-01-01

    Full text of publication follows: Plasma facing components act as actively cooled thermal shields to sustain thermal and particle loads during normal and transient operations in ITER (International Thermonuclear Experimental Reactor). The plasma-facing layer is referred to as 'armour', which is made of either carbon fibre reinforced carbon composite (CFC) or tungsten (W). CFC is the reference design solution for the lower part of the vertical target of the ITER divertor. The armour is joined onto an actively cooled substrate, the heat sink, made of precipitation hardened copper alloy CuCrZr through a thin pure copper interlayer to decrease, by plastic deformation, the joint interface stresses; in fact, the CFC to Cu joint is affected by the CTE mismatch between the ceramic and metallic material. A new method of joining CFC to copper and CFC/Cu to CuCrZr alloy was effectively developed for the flat-type configuration; the feasibility of this process also for mono-block geometry and the development of a procedure for testing mono-block-type mock-ups is described in this work. The mono-block configuration consists of copper alloy pipe shielded by CFC blocks. It is worth noting that in mono-block configuration, the large thermal expansion mismatch between CFC and copper alloy is more significant than for flat-tile configuration, due to curved interfaces. The joining technique foresees a single-step brazing process: the brazing of the three materials (CFC-Cu-CuCrZr) can be performed in a single heat treatment using the same Cu/Ge based braze. The composite surface was modified by solid state reaction with chromium with the purpose of increasing the wettability of CFC by the brazing alloy. The CFC substrate reacts with Cr which, forming a carbide layer, allows a large reduction of the contact angle; then, the brazing of CFC to pure copper and pure copper to CuCrZr by the same treatment is feasible. This process allows to obtain good joints using a non-active brazing

  10. Setting Passing Scores on Passage-Based Tests: A Comparison of Traditional and Single-Passage Bookmark Methods

    Science.gov (United States)

    Skaggs, Gary; Hein, Serge F.; Awuor, Risper

    2007-01-01

    In this study, a variation of the bookmark standard setting procedure for passage-based tests is proposed in which separate ordered item booklets are created for the items associated with each passage. This variation is compared to the traditional bookmark procedure for a fifth-grade reading test. The results showed that the single-passage…

  11. Reliability of Single-Leg Balance and Landing Tests in Rugby Union; Prospect of Using Postural Control to Monitor Fatigue

    Directory of Open Access Journals (Sweden)

    Jordan C. Troester, Jason G. Jasmin, Rob Duffield

    2018-06-01

    Full Text Available The present study examined the inter-trial (within test and inter-test (between test reliability of single-leg balance and single-leg landing measures performed on a force plate in professional rugby union players using commercially available software (SpartaMARS, Menlo Park, USA. Twenty-four players undertook test – re-test measures on two occasions (7 days apart on the first training day of two respective pre-season weeks following 48h rest and similar weekly training loads. Two 20s single-leg balance trials were performed on a force plate with eyes closed. Three single-leg landing trials were performed by jumping off two feet and landing on one foot in the middle of a force plate 1m from the starting position. Single-leg balance results demonstrated acceptable inter-trial reliability (ICC = 0.60-0.81, CV = 11-13% for sway velocity, anterior-posterior sway velocity, and mediolateral sway velocity variables. Acceptable inter-test reliability (ICC = 0.61-0.89, CV = 7-13% was evident for all variables except mediolateral sway velocity on the dominant leg (ICC = 0.41, CV = 15%. Single-leg landing results only demonstrated acceptable inter-trial reliability for force based measures of relative peak landing force and impulse (ICC = 0.54-0.72, CV = 9-15%. Inter-test results indicate improved reliability through the averaging of three trials with force based measures again demonstrating acceptable reliability (ICC = 0.58-0.71, CV = 7-14%. Of the variables investigated here, total sway velocity and relative landing impulse are the most reliable measures of single-leg balance and landing performance, respectively. These measures should be considered for monitoring potential changes in postural control in professional rugby union.

  12. CHARACTERIZATION TESTING AND ANALYSIS OF SINGLE CELL SO2 DEPOLARIZED ELECTROLYZER

    Energy Technology Data Exchange (ETDEWEB)

    Steimke, J; Timothy Steeper, T

    2006-09-15

    This document reports work performed at the Savannah River National Laboratory (SRNL) that further develops the use of a proton exchange membrane or PEM-type electrochemical cell to produce hydrogen via SO{sub 2}-depolarized water electrolysis. This work was begun at SRNL in 2005. This research is valuable in achieving the ultimate goal of an economical hydrogen production process based on the Hybrid Sulfur (HyS) Cycle. The HyS Process is a hybrid thermochemical cycle that may be used in conjunction with advanced nuclear reactors or centralized solar receivers to produce hydrogen by water-splitting. Like all other sulfur-based cycles, HyS utilizes the high temperature thermal decomposition of sulfuric acid to produce oxygen. The unique aspect of HyS is the generation of hydrogen in a water electrolyzer that is operated under conditions where dissolved sulfur dioxide depolarizes the anodic reaction, resulting in substantial voltage reduction. Sulfur dioxide is oxidized at the anode, producing sulfuric acid that is sent to the acid decomposition portion of the cycle. The focus of this work was to conduct single cell electrolyzer tests in order to prove the concept of SO{sub 2}-depolarization and to determine how the results can be used to evaluate the performance of key components of the HyS Process. A test facility for conducting SO{sub 2}-depolarized electrolyzer (SDE) testing was designed, constructed and commissioned. The maximum cell current is 50 amperes, which is equivalent to a hydrogen production rate of approximately 20 liters per hour. Feed to the anode of the electrolyzer is sulfuric acid solutions containing dissolved sulfur dioxide. The partial pressure of sulfur dioxide may be varied in the range of 1 to 6 atm (15 to 90 psia). Temperatures may be controlled in the range from ambient to 80 C. Hydrogen generated at the cathode of the cell is collected for the purpose of flow measurement and composition analysis. The test facility proved to be easy to

  13. Single well injection withdrawal tests (SWIW) in fractured rock. Some aspects on interpretation

    Energy Technology Data Exchange (ETDEWEB)

    Neretnieks, Ivars [Dept. of Chemical Engineering and Technology, Royal Inst. of Technology, Stockholm (Sweden)

    2007-08-15

    Single-Well-Injection-Withdrawal, SWIW, tests are used to try to extract information on fracture apertures, sorption and diffusion properties and dispersion information in individual fractures. It is done by injecting a given amount of traced water into an isolated fracture. After a waiting period water is withdrawn from the fracture and the tracer concentration is measured. The concentration time curve is fitted to a model and the parameter values quantifying the different interaction mechanisms are determined. A number of different mechanisms influence the recovery of the tracer. One or more of the following mechanisms are considered. They include: dispersion due to velocity differences, sorption on fracture surface and on infill, diffusion in rock fragments in the fracture, diffusion between 'streamlines', diffusion into rock matrix and other stagnant water volumes, sorption kinetics and slow drift of the plume caused by the natural gradient. Many of the interaction mechanisms can influence the recovery curve in a similar way. For example, diffusion into rock matrix water and into stagnant water in the fracture adjacent to the flowing channels cannot be distinguished if only one tracer is used. Tracers with different properties can in principle be used but they will encounter different parts of the fracture, the sorbing tracer will move out less from the injection point than a nonsorbing tracer will. Diffusion and sorption in small particles in the flowpath can influence the recovery curve in a similar way as rock matrix diffusion does. Dispersion caused by diffusion between 'streamlines', Taylor dispersion, can give very different results in channels of different shapes. Such dispersion effects can be difficult to distinguish from matrix diffusion effects. Dispersion coefficients obtained in a SWIW test may have little relation to dispersion of a tracer moving from A to B. This is partly due to the different mechanisms and partly due to

  14. Single well injection withdrawal tests (SWIW) in fractured rock. Some aspects on interpretation

    International Nuclear Information System (INIS)

    Neretnieks, Ivars

    2007-08-01

    Single-Well-Injection-Withdrawal, SWIW, tests are used to try to extract information on fracture apertures, sorption and diffusion properties and dispersion information in individual fractures. It is done by injecting a given amount of traced water into an isolated fracture. After a waiting period water is withdrawn from the fracture and the tracer concentration is measured. The concentration time curve is fitted to a model and the parameter values quantifying the different interaction mechanisms are determined. A number of different mechanisms influence the recovery of the tracer. One or more of the following mechanisms are considered. They include: dispersion due to velocity differences, sorption on fracture surface and on infill, diffusion in rock fragments in the fracture, diffusion between 'streamlines', diffusion into rock matrix and other stagnant water volumes, sorption kinetics and slow drift of the plume caused by the natural gradient. Many of the interaction mechanisms can influence the recovery curve in a similar way. For example, diffusion into rock matrix water and into stagnant water in the fracture adjacent to the flowing channels cannot be distinguished if only one tracer is used. Tracers with different properties can in principle be used but they will encounter different parts of the fracture, the sorbing tracer will move out less from the injection point than a nonsorbing tracer will. Diffusion and sorption in small particles in the flowpath can influence the recovery curve in a similar way as rock matrix diffusion does. Dispersion caused by diffusion between 'streamlines', Taylor dispersion, can give very different results in channels of different shapes. Such dispersion effects can be difficult to distinguish from matrix diffusion effects. Dispersion coefficients obtained in a SWIW test may have little relation to dispersion of a tracer moving from A to B. This is partly due to the different mechanisms and partly due to different time scales

  15. Single-Event Latchup Testing of the Micrel MIC4424 Dual Power MOSFET Driver

    Science.gov (United States)

    Pellish, J. A.; Boutte, A.; Kim, H.; Phan, A.; Topper, A.

    2016-01-01

    We conducted 47 exposures of four different MIC4424 devices and did not observe any SEL or high-current events. This included worst-case conditions with a LET of 81 MeV-sq cm/mg, applied voltage of 18.5 V, a case temperature greater than 120 C, and a final fluence of 1x10(exp 7)/sq cm. We also monitored both the outputs for the presence of SETs. While the period of the 1 MHz square wave was slightly altered in some cases, no pulses were added or deleted. 1. Purpose: The purpose of this testing is to characterize the BiCMOS/DMOS Micrel MIC4424 dual, non-inverting MOSFET driver for single-event latchup (SEL) susceptibility. These data will be used for flight lot evaluation purposes. 2. Devices Tested: The MIC4423/4424/4425 family are highly reliable BiCMOS/DMOS buffer/driver MOSFET drivers. They are higher output current versions of the MIC4426/4427/4428. They can survive up to 5V of noise spiking, of either polarity, on the ground pin. They can accept, without either damage or logic upset, up to half an amp of reverse current (either polarity) forced back into their outputs. Primarily intended for driving power MOSFETs, the MIC4423/4424/4425 drivers are suitable for driving other loads (capacitive, resistive, or inductive) which require low-impedance, high peak currents, and fast switching times. Heavily loaded clock lines, coaxial cables, or piezoelectric transducers are some examples. The only known limitation on loading is that total power dissipated in the driver must be kept within the maximum power dissipation limits of the package. Five (5) parts were provided for SEL testing. We prepared four parts for irradiation and reserved one piece as an un-irradiated control. More information about the devices can be found in Table 1. The parts were prepared for testing by removing the lid from the CDIP package to expose the target die. The parts were then soldered to small copper circuit adapter boards for easy handling. These parts are fabricated in a bulk Bi

  16. Beam instability Workshop - plenary sessions

    International Nuclear Information System (INIS)

    2001-01-01

    The purpose of this workshop was to provide a review of the mechanisms of limiting beam instabilities, their cures, including feedback, and beam measurement for synchrotron radiation light sources. 12 plenary sessions took place whose titles are: 1) challenging brilliance and lifetime issues with increasing currents; 2) limiting instabilities in multibunch; 3) experience from high currents in B factories; 4) longitudinal dynamics in high intensity/bunch; 5) Transverse instabilities for high intensity/bunch; 6) working group introduction from ESRF experience; 7) impedance modelling: simulations, minimization; 8) report on the broadband impedance measurements and modelling workshop; 9) feedback systems for synchrotron light sources; 10) beam instabilities diagnostics; 11) harmonic cavities: the pros and cons; and 12) experimental study of fast beam-ion instabilities at PLS. This document gathers the 12 articles that were presented during these sessions

  17. National Sessions of Radiation Protection

    International Nuclear Information System (INIS)

    Sociedad Argentina de Radioproteccion

    2012-01-01

    The Radioprotection Argentine Society (SAR) was organized the National Sessions on Radiation Protection 2012 in order to continue the exchange in the radiation protection community in the country, on work areas that present a challenge to the profession. The new recommendations of the ICRP and the IAEA Safety Standards (2011), among others, includes several topics that are necessary to develop. The SAR wants to encourage different organizations from Argentina, to submit projects that are developing in order to strengthen radiation protection.

  18. Inflammatory changes upon a single maximal exercise test in depressed patients and healthy controls.

    Science.gov (United States)

    Boettger, Silke; Müller, Hans-Josef; Oswald, Klaus; Puta, Christian; Donath, Lars; Gabriel, Holger H W; Bär, Karl-Jürgen

    2010-04-16

    Patients with major depressive disorder (MDD) have repeatedly been described to exhibit both a humoral as well as a cellular pro-inflammatory state. Acute exercise, representing physical stress, can further aggravate such an immune dysbalance. In the light of recommended exercise programmes for depressed patients, we aimed to investigate the inflammatory response to exercise in patients with MDD. Blood cells counts and concentrations of the pro-inflammatory cytokines IL-1ss and IL-6 as well as the anti-inflammatory cytokine IL-10 were obtained before and after a single maximum exercise test in 15 patients suffering from MDD and 15 controls applying a stepwise exhaustion protocol. Patients showed increased white cell counts before and after exercise. While starting from different baseline levels, however, the relative increase in both humoral and cellular inflammatory parameters did not differ between groups. The results from this study suggest that physical training programmes for MDD patients do not bear a dramatically increased risk for acute pro-inflammatory exacerbations. Thus, continuous training programmes that have been shown to reduce the pro-inflammatory state in these patients can be recommended. Copyright 2010 Elsevier Inc. All rights reserved.

  19. Happy eating: the single target implicit association test predicts overeating after positive emotions.

    Science.gov (United States)

    Bongers, Peggy; Jansen, Anita; Houben, Katrijn; Roefs, Anne

    2013-08-01

    For many years, questionnaires have been considered the standard when examining emotional eating behavior. However, recently, some controversy has arisen about these questionnaires, and their usefulness in identifying emotional eaters has been questioned. The current study aimed to investigate the Single Target Implicit Association Test (ST-IAT) as a measure of emotional eating. Two ST-IATs (assessing food-positive and food-negative associations respectively) and the Dutch Eating Behaviour Questionnaire (DEBQ) were compared in undergraduate students. A positive, negative or neutral mood was induced by means of a film clip, and milkshake consumption was measured during and after the mood induction. It was hypothesized that participants with strong emotion-food associations on the ST-IATs (i.e., IAT-emotional eaters) would consume more food in the emotion induction condition corresponding to that emotion, as compared to those with weak emotion-food associations as well as to those in the neutral condition. Participants who scored high on both the positive and negative ST-IATs ate more during a positive mood induction than during a negative mood induction. This effect did not extend to milkshake consumption after the mood induction procedure. In addition, IAT-positive emotional eaters consumed more food than IAT-non-emotional eaters. No effects of the DEBQ on milkshake consumption were found. It is concluded that the ST-IAT has potential as a measure of emotional eating. © 2013 Elsevier Ltd. All rights reserved.

  20. THE DESIGN, FABRICATION AND PRELIMINARY TESTING OF AN INDIGENOUS SINGLE SCREW EXTRUDER

    Directory of Open Access Journals (Sweden)

    FOLASAYO T. FAYOSE

    2017-10-01

    Full Text Available Developing countries including Nigeria have become dumping grounds of unserviceable and broken down imported machineries because of poor adaptation. Detailed study and design of machines to suit local conditions will prevent poor adaptation of imported machines and high initial costs. In this study, a single screw starch extruder was designed, fabricated and tested using locally available materials. The extruder is the dry type and it has 27.12 kg/s capacity, a compression ratio of 4.5: 1 and is powered by a 5.5 kW electric motor. It consists of a hopper, feeding screw, extruder screw rotating in a barrel and variable die, all made of stainless steel. A unit of the machine costs N 470, 390.00.00 as at April 2015. When used to process cassava flour, a maximum temperature of 114°C was attained through viscous dissipation, up to an actual screw speed of 98.96 rpm (1.65 Hz and extruder efficiency of 64%. Barrel temperature varied directly with extrusion time in a polynomial trend while actual extruder screw speed and efficiency varied inversely with extrusion time and it is best fitted with a polynomial trend.

  1. Electrical resistivity monitoring of the single heater test in Yucca Mountain

    International Nuclear Information System (INIS)

    Ramirez, A.

    1997-10-01

    Of the several thermal, mechanical and hydrological measurements being used to monitor the rockmass response in the Single Heater Test, electrical resistance tomography (ERT) is being used to monitor the movement of liquid water with a special interest in the movement of condensate out of the system. Images of resistivity change were calculated using data collected before, during and after the heating episode. This report will concentrate on the results obtained after heating ceased; previous reports discuss the results obtained during the heating phase. The changes recovered show a region of increasing resistivity approximately centered around the heater as the rock mass cooled. The size of this region grows with time and the resistivity increases become stronger. The increases in resistivity are caused by both temperature and saturation changes. The Waxman Smits model has been used to calculate rock saturation after accounting for temperature effects. The saturation estimates suggest that during the heating phase, a region of drying forms around the heater. During the cooling phase, the dry region has remained relatively stable. Wetter rock regions which developed below the heater during the heating phase, are slowly becoming smaller in size during the cooling phase. The last set of images indicate that some rewetting of the dry zone may be occurring. The accuracy of the saturation estimates depends on several factors that are only partly understood

  2. Preparation, characterization and single cell testing of new ionic conducting polymers for fuel cell applications

    Science.gov (United States)

    Escribano, P. G.; del Río y, C.; Acosta, J. L.

    In this work, heterogeneous sulfonation and both, structural and electrical characterization of a mixture composed on block copolymer ionomers (HSBS and EPDM) and commercial silica, are studied. The incorporation of sulfonic groups was checked by infrared spectroscopy (FTIR-ATR). Microstructure was studied by means of dynamic mechanical analysis (DMA). Also, water uptake and methanol crossover were determined, and the results were compared with those of Nafion ® 117. Electrical behavior was recorded by means of electrochemical impedance spectroscopy (EIS) at different hydration times. Results show that sulfonation of the styrene rings has effectively occurred. Conductivity values are similar to Nafion and they improve with hydration time. Methanol crossover is lower than in Nafion. Finally, a single complete proton exchange membrane fuel cell (PEMFC) as a whole was tested obtaining the polarization and power curves at different temperatures and pressures, and modeling it by an electrical equivalent circuit (EC) in the symmetrical mode (SM) configuration using the EIS technique. This study offers a physical interpretation relating physical parameters to several processes occurring in the system. Power density values are higher than in Nafion.

  3. Single-crate stand-alone CAMAC control system for a negative ion source test facility

    International Nuclear Information System (INIS)

    Juras, R.C.; Ziegler, N.F.

    1979-01-01

    A single-crate CAMAC system was configured to control a negative ion source development facility at ORNL and control software was written for the crate microcomputer. The software uses inputs from a touch panel and a shaft encoder to control the various operating parameters of the test facility and uses the touch panel to display the operating status. Communication to and from the equipment at ion source potential is accomplished over optical fibers from an ORNL-built CAMAC module. A receiver at ion source potential stores the transmitted data and some of these stored values are then used to control discrete parameters of the ion source (i.e., power supply on or off). Other stored values are sent to a multiplexed digital-to-analog converter to provide analog control signals. A transmitter at ion source potential transmits discrete status information and several channels of analog data from an analog-to-digital converter back to the ground-potential receiver where it is stored to be read and displayed by the software

  4. Comparing SessionStateReveal and EphemeralKeyReveal for Diffie-Hellman Protocols

    Science.gov (United States)

    Ustaoglu, Berkant

    Both the "eCK" model, by LaMacchia, Lauter and Mityagin, and the "CK01" model, by Canetti and Krawczyk, address the effect of leaking session specific ephemeral data on the security of key establishment schemes. The CK01-adversary is given a SessionStateReveal query to learn session-specific private data defined by the protocol specification, whereas the eCK-adversary is equipped with an EphemeralKeyReveal query to access all ephemeral private input required to carry session computations. SessionStateReveal cannot be issued against the test session; by contrast EphemeralKeyReveal can be used against the test session under certain conditions. On the other hand, it is not obvious how EphemeralKeyReveal compares to SessionStateReveal. Thus it is natural to ask which model is more useful and practically relevant.

  5. Correlation of single-breath count test and neck flexor muscle strength with spirometry in myasthenia gravis.

    Science.gov (United States)

    Elsheikh, Bakri; Arnold, W David; Gharibshahi, Shahram; Reynolds, Jerold; Freimer, Miriam; Kissel, John T

    2016-01-01

    Although formal spirometry is the gold standard for monitoring respiratory function in patients with myasthenia gravis (MG), such testing is often delayed or unavailable. There is a need for a simple bedside test that can accurately measure respiratory function. We conducted a prospective, cross-sectional, single-blind study in adults with acetylcholine receptor antibody positive MG. Participants performed the single breath count test (SBCT) and underwent manual muscle strength testing, and a respiratory therapist performed spirometry blinded to SBCT and strength results. Thirty-one patients, aged 57 ± 19 years participated. SBCT showed significant correlations with forced vital capacity (FVC), negative inspiratory force, and neck flexor strength (P strength (P = 0.02) but no correlation with shoulder abductor strength. These data suggest that the SBCT and neck flexor strength testing are valuable tools for bedside assessment of respiratory function in MG patients. © 2015 Wiley Periodicals, Inc.

  6. Aggregated Search Interface Preferences in Multi-Session Search Tasks

    NARCIS (Netherlands)

    Bron, M.; van Gorp, J.; Nack, F.; Baltussen, L.B.; de Rijke, M.

    2013-01-01

    Aggregated search interfaces provide users with an overview of results from various sources. Two general types of display exist: tabbed, with access to each source in a separate tab, and blended, which combines multiple sources into a single result page. Multi-session search tasks, e.g., a research

  7. Typing of 49 autosomal SNPs by single base extension and capillary electrophoresis for forensic genetic testing

    DEFF Research Database (Denmark)

    Børsting, Claus; Tomas Mas, Carmen; Morling, Niels

    2012-01-01

    We describe a method for simultaneous amplification of 49 autosomal single nucleotide polymorphisms (SNPs) by multiplex PCR and detection of the SNP alleles by single base extension (SBE) and capillary electrophoresis. All the SNPs may be amplified from only 100 pg of genomic DNA and the length...

  8. FY2016 ILAW Glass Corrosion Testing with the Single-Pass Flow-Through Method

    Energy Technology Data Exchange (ETDEWEB)

    Neeway, James J. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Asmussen, Robert M. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Parruzot, Benjamin PG [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Cordova, Elsa [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Williams, Benjamin D. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Leavy, Ian I. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Stephenson, John R. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); McElroy, Erin M. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2017-04-21

    The inventory of immobilized low-activity waste (ILAW) produced at the Hanford Tank Waste Treatment and Immobilization Plant (WTP) will be disposed of at the near-surface, on-site Integrated Disposal Facility (IDF). When groundwater comes into contact with the waste form, the glass will corrode and radionuclides will be released into the near-field environment. Because the release of the radionuclides is dependent on the dissolution rate of the glass, it is important that the performance assessment (PA) model accounts for the dissolution rate of the glass as a function of various chemical conditions. To accomplish this, an IDF PA model based on Transition State Theory (TST) can be employed. The model is able to account for changes in temperature, exposed surface area, and pH of the contacting solution as well as the effect of silicon concentrations in solution, specifically the activity of orthosilicic acid (H4SiO4), whose concentration is directly linked to the glass dissolution rate. In addition, the IDF PA model accounts for the alkali-ion exchange process as sodium is leached from the glass and into solution. The effect of temperature, pH, H4SiO4 activity, and the rate of ion-exchange can be parameterized and implemented directly into the PA rate law model. The rate law parameters are derived from laboratory tests with the single-pass flow-through (SPFT) method. To date, rate law parameters have been determined for seven ILAW glass compositions, thus additional rate law parameters on a wider range of compositions will supplement the existing body of data for PA maintenance activities. The data provided in this report can be used by ILAW glass scientists to further the understanding of ILAW glass behavior, by IDF PA modelers to use the rate law parameters in PA modeling efforts, and by Department of Energy (DOE) contractors and decision makers as they assess the IDF PA program.

  9. C.O.D. toughness testing of medium strength steel as a preliminary development for single specimen J integral toughness tests of SA533-B steel

    International Nuclear Information System (INIS)

    Dean, P.; Tait, R.B.; Garrett, G.G.

    1981-10-01

    The primary purpose of this project is to set up a test facility and to develop the necessary expertise to enable reliable elasto-plastic fracture toughness tests to be performed. Initially, tests are to be conducted on material similar to that used in the Koeberg pressure vessel walls, with the ultimate goal of performing single specimen J integral tests on the pressure vessel steel itself to determine through-thickness toughness variations. The project will comprise a number of stages, each one necessary for the development of the techniques used in J integral testing. These include: (i) development of an appropriate specimen design, of suitable size and shape that is applicable to both crack opening displacement (C.O.D.) and J integral tests; (ii) development, testing and calibration of the necessary associated mechanical and electrical equipment (e.g. clip gauge, amplifiers, interface unit, etc.), with (iii) an estimation of the probable errors and noise levels with a view to their elimantion, leading to (iv) perfection of the sensitivity and reproducibility of, firstly, the multiple specimen C.O.D. technique and, secondly, the multiple specimen J integral techniques. (v) Based on the above techniques, development of the single specimen J integral test method incorporating development of a computerised testing procedure. All the above procedure is to be conducted on similar, but non-Koeberg pressure vessel material ('ROQ Tough'). (vi) Finally, development and testing of both multiple specimen and single specimen J integral tests on actual SA533B material and an investigation of the through thickness toughness and fatigue crack propagation behaviour

  10. Towards a Unified Testing Framework for Single-Sided Deafness Studies: A Consensus Paper.

    Science.gov (United States)

    Van de Heyning, Paul; Távora-Vieira, Dayse; Mertens, Griet; Van Rompaey, Vincent; Rajan, Gunesh P; Müller, Joachim; Hempel, John Martin; Leander, Daniel; Polterauer, Daniel; Marx, Mathieu; Usami, Shin-Ichi; Kitoh, Ryosuke; Miyagawa, Maiko; Moteki, Hideaki; Smilsky, Kari; Baumgartner, Wolf-Dieter; Keintzel, Thomas Georg; Sprinzl, Georg Mathias; Wolf-Magele, Astrid; Arndt, Susan; Wesarg, Thomas; Zirn, Stefan; Baumann, Uwe; Weissgerber, Tobias; Rader, Tobias; Hagen, Rudolf; Kurz, Anja; Rak, Kristen; Stokroos, Robert; George, Erwin; Polo, Ruben; Medina, María Del Mar; Henkin, Yael; Hilly, Ohad; Ulanovski, David; Rajeswaran, Ranjith; Kameswaran, Mohan; Di Gregorio, Maria Fernanda; Zernotti, Mario E

    2016-01-01

    While hearing aids for a contralateral routing of signals (CROS-HA) and bone conduction devices have been the traditional treatment for single-sided deafness (SSD) and asymmetric hearing loss (AHL), in recent years, cochlear implants (CIs) have increasingly become a viable treatment choice, particularly in countries where regulatory approval and reimbursement schemes are in place. Part of the reason for this shift is that the CI is the only device capable of restoring bilateral input to the auditory system and hence of possibly reinstating binaural hearing. Although several studies have independently shown that the CI is a safe and effective treatment for SSD and AHL, clinical outcome measures in those studies and across CI centers vary greatly. Only with a consistent use of defined and agreed-upon outcome measures across centers can high-level evidence be generated to assess the safety and efficacy of CIs and alternative treatments in recipients with SSD and AHL. This paper presents a comparative study design and minimum outcome measures for the assessment of current treatment options in patients with SSD/AHL. The protocol was developed, discussed, and eventually agreed upon by expert panels that convened at the 2015 APSCI conference in Beijing, China, and at the CI 2016 conference in Toronto, Canada. A longitudinal study design comparing CROS-HA, BCD, and CI treatments is proposed. The recommended outcome measures include (1) speech in noise testing, using the same set of 3 spatial configurations to compare binaural benefits such as summation, squelch, and head shadow across devices; (2) localization testing, using stimuli that rove in both level and spectral content; (3) questionnaires to collect quality of life measures and the frequency of device use; and (4) questionnaires for assessing the impact of tinnitus before and after treatment, if applicable. A protocol for the assessment of treatment options and outcomes in recipients with SSD and AHL is presented

  11. CIME Session on Pluripotential Theory

    CERN Document Server

    Patrizio, Giorgio; Berteloot, Francois; Demailly, Jean Pierre

    2013-01-01

    Pluripotential theory is a very powerful tool in geometry, complex analysis and dynamics. This volume brings together the lectures held at the 2011 CIME session on "pluripotential theory" in Cetraro, Italy. This CIME course focused on complex Monge-Ampére equations, applications of pluripotential theory to Kahler geometry and algebraic geometry and to holomorphic dynamics. The contributions provide an extensive description of the theory and its very recent developments, starting from basic introductory materials and concluding with open questions in current research.

  12. Working session 3: Tubing integrity

    International Nuclear Information System (INIS)

    Cueto-Felgueroso, C.; Strosnider, J.

    1997-01-01

    Twenty-three individuals representing nine countries (Belgium, Canada, the Czech Republic, France, Japan, the Slovak Republic, Spain, the UK, and the US) participated in the session on tube integrity. These individuals represented utilities, vendors, consultants and regulatory authorities. The major subjects discussed by the group included overall objectives of managing steam generator tube degradation, necessary elements of a steam generator degradation management program, the concept of degradation specific management, structural integrity evaluations, leakage evaluations, and specific degradation mechanisms. The group's discussions on these subjects, including conclusions and recommendations, are summarized in this article

  13. Racial/ethnic and gender differences among older adults in nonmonogamous partnerships, time spent single, and human immunodeficiency virus testing.

    Science.gov (United States)

    Harawa, Nina T; Leng, Mei; Kim, Junyeop; Cunningham, William E

    2011-12-01

    A higher frequency of nonmonogamy, due in part to lower marriage prevalence, may contribute to elevated human immunodeficiency virus (HIV)/sexually transmitted disease rates among older blacks. To examine race and gender differences in nonmonogamy, time spent single (i.e., not married or cohabiting), and HIV testing in older adults, we analyzed US population-based data from the 2005-2006 National Social Life, Health, and Aging Project for 2825 heterosexual participants ages 57 to 85 years. Blacks spent greater portions of their adult lives single than did Hispanics or whites and were far more likely to report recent nonmonogamous partnerships (23.4% vs. 10.0% and 8.2%). Among individuals reporting sex in the prior 5 years, nonmonogamous partnerships were strongly associated with time spent single during the period. Control for time spent single and other covariates reduced the association of black race with nonmonogamous partnerships for men, but increased it for women. Less than 20% reported ever testing for HIV; less than 6% had been recommended testing by a provider. Testing rates, highest in black men and white women, differed little by history of nonmonogamous partnerships within gender strata. Singlehood helps to explain higher nonmonogamous partnership rates in older black men but not in older black women. Older adults rarely receive or are recommended HIV testing, a key strategy for reducing heterosexual HIV transmission.

  14. Single-Leg Hop Test Performance and Isokinetic Knee Strength After Anterior Cruciate Ligament Reconstruction in Athletes.

    Science.gov (United States)

    Sueyoshi, Ted; Nakahata, Akihiro; Emoto, Gen; Yuasa, Tomoki

    2017-11-01

    Isokinetic strength and hop tests are commonly used to assess athletes' readiness to return to sport after knee surgery. The purpose of this study was to investigate the results of single-leg hop and isokinetic knee strength testing in athletes who underwent anterior cruciate ligament reconstruction (ACLR) upon returning to sport participation as well as to study the correlation between these 2 test batteries. The secondary purpose was to compare the test results by graft type (patellar tendon or hamstring). It was hypothesized that there would be no statistically significant limb difference in either isokinetic knee strength or single-leg hop tests, that there would be a moderate to strong correlation between the 2 test batteries, and that there would be no significant difference between graft types. Cross-sectional study; Level of evidence, 3. Twenty-nine high school and collegiate athletes who underwent ACLR participated in this study. At the time of return to full sport participation, a series of hop tests and knee extension/flexion isokinetic strength measurements were conducted. The results were analyzed using analysis of variance and Pearson correlation ( r ). The timed 6-m hop test was the only hop test that showed a significant difference between the involved and uninvolved limbs (2.3 and 2.2 seconds, respectively; P = .02). A significant difference between limbs in knee strength was found for flexion peak torque/body weight at 180 deg/s ( P = .03), flexion total work/body weight at 180 deg/s ( P = .04), and flexion peak torque/body weight at 300 deg/s ( P = .03). The strongest correlation between the hop tests and knee strength was found between the total distance of the hop tests and flexion total work/body weight at 300 deg/s ( r = 0.69) and between the timed 6-m hop test and flexion peak torque/body weight at 300 deg/s ( r = -0.54). There was no statistically significant difference in hop test performance or isokinetic knee strength between graft types

  15. Petting away pre-exam stress: The effect of therapy dog sessions on student well-being.

    Science.gov (United States)

    Ward-Griffin, Emma; Klaiber, Patrick; Collins, Hanne K; Owens, Rhea L; Coren, Stanley; Chen, Frances S

    2018-03-12

    Recently, many universities have implemented programmes in which therapy dogs and their handlers visit college campuses. Despite the immense popularity of therapy dog sessions, few randomized studies have empirically tested the efficacy of such programmes. The present study evaluates the efficacy of such a therapy dog programme in improving the well-being of university students. This research incorporates two components: (a) a pre/post within-subjects design, in which 246 participants completed a brief questionnaire immediately before and after a therapy dog session and (b) an experimental design with a delayed-treatment control group, in which all participants completed baseline measures and follow-up measures approximately 10 hr later. Only participants in the experimental condition experienced the therapy dog session in between the baseline and follow-up measures. Analyses of pre/post data revealed that the therapy dog sessions had strong immediate benefits, significantly reducing stress and increasing happiness and energy levels. In addition, participants in the experimental group reported a greater improvement in negative affect, perceived social support, and perceived stress compared with those in the delayed-treatment control group. Our results suggest that single, drop-in, therapy dog sessions have large and immediate effects on students' well-being, but also that the effects after several hours are small. Copyright © 2018 John Wiley & Sons, Ltd.

  16. Criticality of Low-Energy Protons in Single-Event Effects Testing of Highly-Scaled Technologies

    Science.gov (United States)

    Pellish, Jonathan A.; Marshall, Paul W.; Rodbell, Kenneth P.; Gordon, Michael S.; LaBel, Kenneth A.; Schwank, James R.; Dodds, Nathaniel A.; Castaneda, Carlos M.; Berg, Melanie D.; Kim, Hak S.; hide

    2014-01-01

    We report low-energy proton and low-energy alpha particle single-event effects (SEE) data on a 32 nm silicon-on-insulator (SOI) complementary metal oxide semiconductor (CMOS) latches and static random access memory (SRAM) that demonstrates the criticality of using low-energy protons for SEE testing of highly-scaled technologies. Low-energy protons produced a significantly higher fraction of multi-bit upsets relative to single-bit upsets when compared to similar alpha particle data. This difference highlights the importance of performing hardness assurance testing with protons that include energy distribution components below 2 megaelectron-volt. The importance of low-energy protons to system-level single-event performance is based on the technology under investigation as well as the target radiation environment.

  17. Single-Event Transient Testing of the Crane Aerospace and Electronics SMHF2812D Dual DC-DC Converter

    Science.gov (United States)

    Casey, Megan

    2015-01-01

    The purpose of this testing was to characterize the Crane Aerospace & Electronics (Crane) Interpoint SMHF2812D for single-event transient (SET) susceptibility. These data shall be used for flight lot evaluation, as well as qualification by similarity of the SMHF family of converters, all of which use the same active components.

  18. Diagnostic accuracy: theoretical models for preimplantation genetic testing of a single nucleus using the fluorescence in situ hybridization technique

    NARCIS (Netherlands)

    Scriven, P. N.; Bossuyt, P. M. M.

    2010-01-01

    The aim of this study was to develop and use theoretical models to investigate the accuracy of the fluorescence in situ hybridization (FISH) technique in testing a single nucleus from a preimplantation embryo without the complicating effect of mosaicism. Mathematical models were constructed for

  19. 42 CFR 84.1145 - Silica dust test; non-powered single-use dust respirators; minimum requirements.

    Science.gov (United States)

    2010-10-01

    ... RESPIRATORY PROTECTIVE DEVICES Dust, Fume, and Mist; Pesticide; Paint Spray; Powered Air-Purifying High Efficiency Respirators and Combination Gas Masks § 84.1145 Silica dust test; non-powered single-use dust... shall be used. (c) Air exhaled through the respirator will be 35° ±2 °C. with 94 ±3 percent relative...

  20. Working session 2: Tubing inspection

    International Nuclear Information System (INIS)

    Guerra, J.; Tapping, R.L.

    1997-01-01

    This session was attended by delegates from 10 countries, and four papers were presented. A wide range of issues was tabled for discussion. Realizing that there was limited time available for more detailed discussion, three topics were chosen for the more detailed discussion: circumferential cracking, performance demonstration (to focus on POD and sizing), and limits of methods. Two other subsessions were organized: one dealt with some challenges related to the robustness of current inspection methods, especially with respect to leaving cracked tubes in service, and the other with developing a chart of current NDE technology with recommendations for future development. These three areas are summarized in turn, along with conclusions and/or recommendations. During the discussions there were four presentations. There were two (Canada, Japan) on eddy current probe developments, both of which addressed multiarray probes that would detect a range of flaws, one (Spain) on circumferential crack detection, and one (JRC, Petten) on the recent PISC III results

  1. DWPF recycle minimization: Brainstorming session

    International Nuclear Information System (INIS)

    Jacobs, R.A.; Poirier, M.R.

    1993-01-01

    The recycle stream from the DWPF constitutes a major source of water addition to the High Level Waste evaporator system. As now designed, the entire flow of 3.5 to 6.5 gal/min (at sign 25% and 75% attainment, respectively), or 2 gal/min during idling, flow to the 2H evaporator system (Tank 43). Substantial improvement in the HLW water balance and tank volume management is expected if the DWPF recycle to the HLW evaporator system can be significantly reduced. A task team has been appointed to study alternatives for reducing the flow to the HLW evaporator system and make recommendations for implementation and/or further study and evaluation. The brainstorming session detailed in this report was designed to produce the first cut options for the task team to further evaluate

  2. Cinema Sessions in Primary Care

    Directory of Open Access Journals (Sweden)

    Francisco Ignacio MORETA-VELAYOS

    2016-04-01

    Full Text Available For a long time films have been used in teaching and at various levels of professional training  and more specifically in the medical area. In this case, through the description of a project developed in a Primary Care Health Center, we intend to justify the use of movies as a tool that could ease, the sometimes difficult task of continued education among Primary Care professionals. We propose different aspects of everyday practice in which cinema can be potentially useful, as well as the way to include it in the Plan of Continued Education of the Centre and its accreditation.Films and issues discussed in each session, and the project evaluation, are detailed.

  3. Validity and reliability of the single-trial line drill test of anaerobic power in basketball players.

    Science.gov (United States)

    Fatouros, I G; Laparidis, K; Kambas, A; Chatzinikolaou, A; Techlikidou, E; Katrabasas, I; Douroudos, I; Leontsini, D; Berberidou, F; Draganidis, D; Christoforidis, C; Tsoukas, D; Kelis, S; Taxildaris, K

    2011-03-01

    This study evaluated the validity, reliability, and sensitivity of the single-trial line drill test (SLDT) for anaerobic power assessment. Twenty-four volunteers were assigned to either a control (C, N.=12) or an experimental (BP, N.=12 basketball players) group. SLDT's (time-to-complete) concurrent validity was evaluated against the Wingate testing (WAnT: mean [MP] and peak power [PP]) and a 30-sec vertical jump testing test (VJT: mean height and MP). Blood lactate concentration was measured at rest and immediately post-test. SLDT's reliability [test-retest intraclass correlation coefficients (ICC), coefficient of variation (CV), Bland-Altman plots] and sensitivity were determined (one-way ANOVA). Kendall's tau correlation analysis revealed correlations (Pbasketball players.

  4. Incorporating Probability Models of Complex Test Structures to Perform Technology Independent FPGA Single Event Upset Analysis

    Science.gov (United States)

    Berg, M. D.; Kim, H. S.; Friendlich, M. A.; Perez, C. E.; Seidlick, C. M.; LaBel, K. A.

    2011-01-01

    We present SEU test and analysis of the Microsemi ProASIC3 FPGA. SEU Probability models are incorporated for device evaluation. Included is a comparison to the RTAXS FPGA illustrating the effectiveness of the overall testing methodology.

  5. Fabrication and Testing of Full-Length Single-Cell Externally Fueled Converters for Thermionic Reactors

    Energy Technology Data Exchange (ETDEWEB)

    Schock, Alfred

    1995-08-01

    Paper presented at the 29th IECEC in Monterey, CA in August 1994. The present paper describes the fabrication and testing of full-length prototypcial converters, both unfueled and fueled, and presents parametric results of electrically heated tests.

  6. Celebrating the tenth conference session

    International Nuclear Information System (INIS)

    1966-01-01

    Full text: This number of the Bulletin appears during a month when the tenth regular session of the Agency's General Conference is being held. It is fitting that among the special arrangements made to give added significance to such an historical landmark should be an opening address by Herr Franz Jonas, Federal President of the host country, Austria. The Festsaal of the Kongresszentrum, in the Hofburg, has now been the centre for every annual session held in Austria, except the first. On that occasion, recorded in the photograph on the cover, the Konzerthaus was made available. A commemorative series of talks dealing with topics of particular interest in the international development of the peaceful uses of atomic energy, delivered by scientists of world distinction was another idea which will add much profound thought to the records of nuclear energy. Under the chairmanship of Professor L.C. Prado, with Dr. W.B. Lewis as Moderator, the subjects chosen by the participants were : The Impact of Atomic Energy in our Society - Sir John Cockcroft; Nuclear Power Systems and their Technical Potentialities - Prof. Alexandre Leipunski; The Commercial Future of Nuclear Power - Dr. William Webster; Nuclear Science in Life Sciences - Dr. A.R. Gopal-Ayengar; Fundamental Research in Atomic Energy Centres - Prof. Louis Neel. These speeches will be reproduced in full in the Agency's Atomic Energy Review. The pages of this issue of the Bulletin are intended to give indications of the stage which the Agency has now reached in some, but by no means all, of its activities in promoting the techniques of atomic energy for the benefit of mankind. (author)

  7. Single Group, Pre- and Post-Test Research Designs: Some Methodological Concerns

    Science.gov (United States)

    Marsden, Emma; Torgerson, Carole J.

    2012-01-01

    This article provides two illustrations of some of the factors that can influence findings from pre- and post-test research designs in evaluation studies, including regression to the mean (RTM), maturation, history and test effects. The first illustration involves a re-analysis of data from a study by Marsden (2004), in which pre-test scores are…

  8. Flow tests of a single fuel element coolant channel for a compact fast reactor for space power

    Science.gov (United States)

    Springborn, R. H.

    1971-01-01

    Water flow tests were conducted on a single-fuel-element cooling channel for a nuclear concept to be used for space power. The tests established a method for measuring coolant flow rate which is applicable to water flow testing of a complete mockup of the reference reactor. The inlet plenum-to-outlet plenum pressure drop, which approximates the overall core pressure drop, was measured and correlated with flow rate. This information can be used for reactor coolant flow and heat transfer calculations. An analytical study of the flow characteristics was also conducted.

  9. The development of evaluating tensile property method used the single notched ring test

    International Nuclear Information System (INIS)

    Bae, Bong Kook; Koo, Jae Mean; Seok, Chang Sung

    2003-01-01

    In this study, the single notched specimen which was proposed the previous study was used to evaluate of the transverse tensile property of zircaloy cladding. The single notched specimen has notches which give stress intensity effect, so both FEM and experiment are needed for the same time. Take a coincidence of tensile behavior about both FEM and experiment, then obtain stress and strain from FEM only. The influence of notch was estimated by comparing the result of experimental, FEM. Then the relationship between stress-strain and displacement was evaluated

  10. The behavioral economics of drug self-administration: a review and new analytical approach for within-session procedures.

    Science.gov (United States)

    Bentzley, Brandon S; Fender, Kimberly M; Aston-Jones, Gary

    2013-03-01

    Behavioral-economic demand curve analysis offers several useful measures of drug self-administration. Although generation of demand curves previously required multiple days, recent within-session procedures allow curve construction from a single 110-min cocaine self-administration session, making behavioral-economic analyses available to a broad range of self-administration experiments. However, a mathematical approach of curve fitting has not been reported for the within-session threshold procedure. We review demand curve analysis in drug self-administration experiments and provide a quantitative method for fitting curves to single-session data that incorporates relative stability of brain drug concentration. Sprague-Dawley rats were trained to self-administer cocaine, and then tested with the threshold procedure in which the cocaine dose was sequentially decreased on a fixed ratio-1 schedule. Price points (responses/mg cocaine) outside of relatively stable brain cocaine concentrations were removed before curves were fit. Curve-fit accuracy was determined by the degree of correlation between graphical and calculated parameters for cocaine consumption at low price (Q(0)) and the price at which maximal responding occurred (P(max)). Removing price points that occurred at relatively unstable brain cocaine concentrations generated precise estimates of Q(0) and resulted in P (max) values with significantly closer agreement with graphical P(max) than conventional methods. The exponential demand equation can be fit to single-session data using the threshold procedure for cocaine self-administration. Removing data points that occur during relatively unstable brain cocaine concentrations resulted in more accurate estimates of demand curve slope than graphical methods, permitting a more comprehensive analysis of drug self-administration via a behavioral-economic framework.

  11. Test-re-test reliability and inter-rater reliability of a digital pelvic inclinometer in young, healthy males and females.

    Science.gov (United States)

    Beardsley, Chris; Egerton, Tim; Skinner, Brendon

    2016-01-01

    Objective. The purpose of this study was to investigate the reliability of a digital pelvic inclinometer (DPI) for measuring sagittal plane pelvic tilt in 18 young, healthy males and females. Method. The inter-rater reliability and test-re-test reliabilities of the DPI for measuring pelvic tilt in standing on both the right and left sides of the pelvis were measured by two raters carrying out two rating sessions of the same subjects, three weeks apart. Results. For measuring pelvic tilt, inter-rater reliability was designated as good on both sides (ICC = 0.81-0.88), test-re-test reliability within a single rating session was designated as good on both sides (ICC = 0.88-0.95), and test-re-test reliability between two rating sessions was designated as moderate on the left side (ICC = 0.65) and good on the right side (ICC = 0.85). Conclusion. Inter-rater reliability and test-re-test reliability within a single rating session of the DPI in measuring pelvic tilt were both good, while test-re-test reliability between rating sessions was moderate-to-good. Caution is required regarding the interpretation of the test-re-test reliability within a single rating session, as the raters were not blinded. Further research is required to establish validity.

  12. High-energy heavy ion testing of VLSI devices for single event ...

    Indian Academy of Sciences (India)

    Unknown

    Single event upset is defined by NASA as 'radiation- induced errors in microelectronic circuits caused when charged particles (usually from the radiation belts or from cosmic rays) lose energy by ionizing the medium through which they pass, leaving behind a wake of elec- tron-hole pairs'. SEU are transient soft errors and ...

  13. Testing the Efficacy of a Scholarship Program for Single Parent, Post-Freshmen, Full Time Undergraduates

    Science.gov (United States)

    Carpenter, Dick M., II; Kaka, Sarah J.; Tygret, Jennifer A.; Cathcart, Katy

    2018-01-01

    This study examines the efficacy of a scholarship program designed to assist single parent, post-freshmen, full time undergraduate students and predictors of success among a sample of said students, where success is defined as progress toward completion, academic achievement, and degree completion. Results of fixed effects regression and…

  14. Analysis and Testing of Ajax-based Single-page Web Applications

    NARCIS (Netherlands)

    Mesbah, A.

    2009-01-01

    This dissertation has focused on better understanding the shifting web paradigm and the consequences of moving from the classical multi-page model to an Ajax-based single-page style. Specifically to that end, this work has examined this new class of software from three main software engineering

  15. Design and Testing of a Thermostable Platform for Multimerization of Single Domain Antibodies

    Science.gov (United States)

    2012-08-01

    from the blood of sharks and camelids (camels and llamas). Largely due to their small size (12‒14 kDa), these molecules have substantial thermostability...H.J. Properties, production, and applications of camelid single domain antibody fragments. Appl. Microbiol. Biot. 2007, 77, 13‒22. 2. Goldman

  16. Single cells for forensic DNA analysis--from evidence material to test tube.

    Science.gov (United States)

    Brück, Simon; Evers, Heidrun; Heidorn, Frank; Müller, Ute; Kilper, Roland; Verhoff, Marcel A

    2011-01-01

    The purpose of this project was to develop a method that, while providing morphological quality control, allows single cells to be obtained from the surfaces of various evidence materials and be made available for DNA analysis in cases where only small amounts of cell material are present or where only mixed traces are found. With the SteREO Lumar.V12 stereomicroscope and UV unit from Zeiss, it was possible to detect and assess single epithelial cells on the surfaces of various objects (e.g., glass, plastic, metal). A digitally operated micromanipulator developed by aura optik was used to lift a single cell from the surface of evidence material and to transfer it to a conventional PCR tube or to an AmpliGrid(®) from Advalytix. The actual lifting of the cells was performed with microglobes that acted as carriers. The microglobes were held with microtweezers and were transferred to the DNA analysis receptacles along with the adhering cells. In a next step, the PCR can be carried out in this receptacle without removing the microglobe. Our method allows a single cell to be isolated directly from evidence material and be made available for forensic DNA analysis. © 2010 American Academy of Forensic Sciences.

  17. The anomaly in a breakthrough curve of a single well "push-pull" tracer test: A density driven effect?

    Science.gov (United States)

    Zeilfelder, Sarah; Hebig, Klaus; Ito, Narimitsu; Machida, Isao; Scheytt, Traugott; Marui, Atsunao

    2013-04-01

    What method is appropriate to investigate an aquifer when there is only one well available? A single well "push-pull" tracer test (PP Test) may be a suitable method in order to characterize an aquifer and to obtain information about the hydraulic and chemical properties when only one well is available for the investigations. In a PP test, a test solution that contains a known amount of solutes and a conservative tracer is injected into the aquifer ("push") and extracted afterwards ("pull"). Optionally, the test solution is flushed out of the well and the casing with untreated test solution with a so called "chaser" before being extracted. Also between the injection and the extraction phase a drifting time may be included. The breakthrough of the tracer during the extraction phase is measured and used for analyses and interpretation. In the last three years, several PP Test campaigns were conducted at two different test sites in Japan (Hebig et al. 2011, Zeilfelder et al. 2012). The aim was to investigate the applicability of the PP Test method in different geological settings and in different types of aquifers. The latest field campaign thus focussed on the question how variations of the setup are influencing the breakthrough curve of the PP Test in order to develop and enhance this method. Also the standardization of the PP Test was an aim of this study. During the campaign, a total of seven PP Tests were performed, while only single aspects of the setup were varied from test to test. The tests differed in injection and extraction rate, in the salinity of the injected test solution and in the use of a chaser solution. The general shapes of the breakthrough curves were similar and conclusions about the repeatability of the PP Test could be drawn. However, a sharp anomaly was observed in the breakthrough curve of one specific setup type. By repeating this PP test under the same boundary conditions, we were able to recreate the anomaly and could exclude any technical

  18. Building a Robust Tumor Profiling Program: Synergy between Next-Generation Sequencing and Targeted Single-Gene Testing.

    Directory of Open Access Journals (Sweden)

    Matthew C Hiemenz

    Full Text Available Next-generation sequencing (NGS is a powerful platform for identifying cancer mutations. Routine clinical adoption of NGS requires optimized quality control metrics to ensure accurate results. To assess the robustness of our clinical NGS pipeline, we analyzed the results of 304 solid tumor and hematologic malignancy specimens tested simultaneously by NGS and one or more targeted single-gene tests (EGFR, KRAS, BRAF, NPM1, FLT3, and JAK2. For samples that passed our validated tumor percentage and DNA quality and quantity thresholds, there was perfect concordance between NGS and targeted single-gene tests with the exception of two FLT3 internal tandem duplications that fell below the stringent pre-established reporting threshold but were readily detected by manual inspection. In addition, NGS identified clinically significant mutations not covered by single-gene tests. These findings confirm NGS as a reliable platform for routine clinical use when appropriate quality control metrics, such as tumor percentage and DNA quality cutoffs, are in place. Based on our findings, we suggest a simple workflow that should facilitate adoption of clinical oncologic NGS services at other institutions.

  19. Building a Robust Tumor Profiling Program: Synergy between Next-Generation Sequencing and Targeted Single-Gene Testing.

    Science.gov (United States)

    Hiemenz, Matthew C; Kadauke, Stephan; Lieberman, David B; Roth, David B; Zhao, Jianhua; Watt, Christopher D; Daber, Robert D; Morrissette, Jennifer J D

    2016-01-01

    Next-generation sequencing (NGS) is a powerful platform for identifying cancer mutations. Routine clinical adoption of NGS requires optimized quality control metrics to ensure accurate results. To assess the robustness of our clinical NGS pipeline, we analyzed the results of 304 solid tumor and hematologic malignancy specimens tested simultaneously by NGS and one or more targeted single-gene tests (EGFR, KRAS, BRAF, NPM1, FLT3, and JAK2). For samples that passed our validated tumor percentage and DNA quality and quantity thresholds, there was perfect concordance between NGS and targeted single-gene tests with the exception of two FLT3 internal tandem duplications that fell below the stringent pre-established reporting threshold but were readily detected by manual inspection. In addition, NGS identified clinically significant mutations not covered by single-gene tests. These findings confirm NGS as a reliable platform for routine clinical use when appropriate quality control metrics, such as tumor percentage and DNA quality cutoffs, are in place. Based on our findings, we suggest a simple workflow that should facilitate adoption of clinical oncologic NGS services at other institutions.

  20. Evaluation of the single-pass flow-through test to support a low-activity waste specification

    International Nuclear Information System (INIS)

    McGrail, B.P.; Peeler, D.K.

    1995-09-01

    A series of single-pass flow-through (SPFT) tests was performed on five reference low-activity waste glasses and a reference glass from the National Institute of Standards and Technology to support a product specification for low-activity waste (LAW) forms. The results showed that the SPFT test provides a means to quantitatively distinguish among LAW glass forms in terms of their forward reaction rate at a given temperature and solution pH. Two of the test glasses were also subjected to SPFT testing at Argonne National Laboratory (ANL). Forward reaction rate constants calculated from the ANL test data were 100 to over 1,000 times larger than the values obtained from the SPFT tests conducted at PNL. An analysis of the ANL results showed that they were inconsistent with independent measurements done on glasses of similar composition, the known pH-dependence of the forward rate, and with the results from low surface-area-to-volume, short duration product consistency tests. Because the data set obtained from the SPFT tests done at PNL was consistent with each of these same factors, a detailed examination of the test procedures used at both laboratories was performed to determine the cause(s) of the discrepancy. The omission of background subtraction in the data analysis procedure and the short-duration (on the order of hours) of the ANL tests are factors that may have significantly affected the calculated rates

  1. Session Report - S. Voinis (Andra)

    International Nuclear Information System (INIS)

    Voinis, Sylvie

    2014-01-01

    The session addressed key issues related to the industrial feasibility of construction. It covered the implementer and regulator points of view. The conclusions derive from three presentations completed by the outcomes of six WG. At the Morsleben Repository, Germany, the licensing of the closure of the repository has been initiated by BfS. The closure concept is based on extensive backfilling with salt concrete complemented by seals. In order to demonstrate the feasibility of constructing such a seal structure an in-situ experiment is performed in a drift of the repository. In the UK, the framework for implementing geological disposal of the higher activity radioactive waste is described in the White Paper published by the UK Government in June 2008. The process to site a facility will be staged and based on voluntarism and partnership with local communities. This process is in its early stage. The paper outlines the work being undertaken by the NDA. In canada, Ontario Power Generation (OPG) has submitted information required for a CNSC licence to prepare the site and construct a DGR for the disposal of low and intermediate level waste from the operation of their nuclear power reactors. That submission includes an Environmental Impact Statement (EIS), as required for a Panel Review under the Canadian Environmental Assessment Act (CEAA), and the information required for a licence application under the NSCA Regulations. Discussions between the proponent and the regulator in the pre-licensing phase, clarified CNSC expectations for the characterization of the site and for the development of the EIS and application. They also helped to ensure that OPG understood these expectations. Outcomes WG session-1: - Start with construction but during operational phase: Simultaneous construction and operation activities. - Need for technical requirements/criteria: So that it can be judged whether 'products' meet the requirements; LT safety issues to be considered during

  2. Evaluating a Pre-Session Homework Exercise in a Standalone Information Literacy Class

    Science.gov (United States)

    Goetz, Joseph E.; Barber, Catherine R.

    2015-01-01

    In this study, researchers evaluate a homework exercise assigned before a standalone information literacy session. Students in a Master of Education program completed a worksheet using the ERIC database thesaurus. The researchers conducted pre- and posttests within a single library session to assess student learning, using a control group for…

  3. One-Session Treatment of Specific Phobias: A Detailed Description and Review of Treatment Efficacy

    Science.gov (United States)

    Zlomke, Kimberly; Davis, Thompson E., III

    2008-01-01

    One-Session Treatment (OST) is a form of massed exposure therapy for the treatment of specific phobias. OST combines exposure, participant modeling, cognitive challenges, and reinforcement in a single session, maximized to three hours. Clients are gradually exposed to steps of their fear hierarchy using therapist-directed behavioral experiments.…

  4. Initial Results of Accelerated Stress Testing on Single-Channel and Multichannel Drivers: Solid-State Lighting Technology Area

    Energy Technology Data Exchange (ETDEWEB)

    None

    2018-02-28

    This report is the first in a series of studies on accelerated stress testing (AST) of drivers used for SSL luminaires, such as downlights, troffers, and streetlights. A representative group of two-stage commercial driver products was exposed to an AST environment consisting of 75°C and 75% relative humidity (7575). These drivers were a mix of single-channel drivers (i.e., a single output current for one LED primary) and multichannel drivers (i.e., separate output currents for multiple LED primaries). This AST environment was chosen because previous testing on downlights with integrated drivers demonstrated that 38% of the sample population failed in less than 2,500 hours of testing using this method. In addition to AST test results, the performance of an SSL downlight product incorporating an integrated, multichannel driver during extended room temperature operational life (RTOL) testing is also reported. A battery of measurements was used to evaluate these products during accelerated testing, including full electrical characterization (i.e., power consumption, PF, total harmonic distortion [THD], and inrush current) and photometric characterization of external LED loads attached to the drivers (i.e., flicker performance and lumen maintenance).

  5. Single event upset tests of a RISC-based fault-tolerant computer

    Energy Technology Data Exchange (ETDEWEB)

    Kimbrough, J.R.; Butner, D.N.; Colella, N.J.; Kaschmitter, J.L.; Shaeffer, D.L.; McKnett, C.L.; Coakley, P.G.; Casteneda, C.

    1996-03-23

    The project successfully demonstrated that dual lock-step comparison of commercial RISC processors is a viable fault-tolerant approach to handling SEU in space environment. The fault tolerant approach on orbit error rate was 38 times less than the single processor error rate. The random nature of the upsets and appearance in critical code section show it is essential to incorporate both hardware and software in the design and operation of fault-tolerant computers.

  6. Synchrony in Dyadic Psychotherapy Sessions

    Science.gov (United States)

    Ramseyer, Fabian; Tschacher, Wolfgang

    Synchrony is a multi-faceted concept used in diverse domains such as physics, biology, and the social sciences. This chapter reviews some of the evidence of nonverbal synchrony in human communication, with a main focus on the role of synchrony in the psychotherapeutic setting. Nonverbal synchrony describes coordinated behavior of patient and therapist. Its association with empathy, rapport and the therapeutic relationship has been pointed out repeatedly, yet close evaluation of empirical studies suggests that the evidence remains inconclusive. Particularly in naturalistic studies, research with quantitative measures of synchrony is still lacking. We introduce a new empirical approach for the study of synchrony in psychotherapies under field conditions: Motion Energy Analysis (MEA). This is a video-based algorithm that quantifies the amount of movement in freely definable regions of interest. Our statistical analysis detects synchrony on a global level, irrespective of the specific body parts moving. Synchrony thus defined can be considered as a general measure of movement coordination between interacting individuals. Data from a sequence of N = 21 therapy sessions taken from one psychotherapy dyad shows a high positive relationship between synchrony and the therapeutic bond. Nonverbal synchrony can thus be considered a promising concept for research on the therapeutic alliance. Further areas of application are discussed.

  7. Columbia University flow instability experimental program: Volume 2. Single tube uniformly heated tests -- Part 2: Uncertainty analysis and data

    International Nuclear Information System (INIS)

    Dougherty, T.; Maciuca, C.; McAssey, E.V. Jr.; Reddy, D.G.; Yang, B.W.

    1990-05-01

    In June 1988, Savannah River Laboratory requested that the Heat Transfer Research Facility modify the flow excursion program, which had been in progress since November 1987, to include testing of single tubes in vertical down-flow over a range of length to diameter (L/D) ratios of 100 to 500. The impetus for the request was the desire to obtain experimental data as quickly as possible for code development work. In July 1988, HTRF submitted a proposal to SRL indicating that by modifying a facility already under construction the data could be obtained within three to four months. In January 1990, HTFR issued report CU-HTRF-T4, part 1. This report contained the technical discussion of the results from the single tube uniformly heated tests. The present report is part 2 of CU-HTRF-T4 which contains further discussion of the uncertainty analysis and the complete set of data

  8. Standardized testing with chlorhexidine in perioperative allergy – a large single-centre evaluation

    DEFF Research Database (Denmark)

    Schjørring Opstrup, Morten; Malling, Hans-Jørgen; Krøigaard, Mogens

    2014-01-01

    BACKGROUND: Perioperative allergic reactions to chlorhexidine are often severe and easily overlooked. Although rare, the prevalence remains unknown. Correct diagnosis is crucial, but no validated provocation model exists, and other diagnostic tests have never been evaluated. The aims were...... to estimate 1) the prevalence of chlorhexidine allergy and 2) the specificity and sensitivity for diagnostic tests for chlorhexidine allergy. METHODS: We included all patients investigated for suspected perioperative allergic reactions in the Danish Anaesthesia Allergy Centre during 2004-2012. The following...... the diameter of negative control. Chlorhexidine allergy was post hoc defined as a relevant clinical reaction to chlorhexidine combined with two or more positive tests. Based on this definition, sensitivity and specificity were estimated for each test. RESULTS: In total, 22 out of 228 patients (9.6%) met...

  9. Multiple Sessions for Information Literacy Instruction are Associated with Improvement in Students’ Research Abilities and Confidence

    Directory of Open Access Journals (Sweden)

    Kelley Wadson

    2017-06-01

    Full Text Available A Review of: Henry, J., Glauner, D., & Lefoe, G. (2015. A double shot of information literacy instruction at a community college. Community & Junior College Libraries, 21(1-2, 27-36. http://dx.doi.org/10.1080/02763915.2015.1120623 Abstract Objective – To evaluate the impact of providing multiple information literacy (IL sessions, instead of a single “one-shot” session, to students in face-to-face and online English courses. Design – Non-experimental, using pre-test and post-test surveys for one group, and only a post-test survey for the other group. Setting – A small community college in North Carolina, United States of America. Subjects – 352 students enrolled in 2 successive 3-credit English courses, excluding those under the age of 18, for a total of 244 participants. Methods – The researchers selected two English courses, ENG 111 and ENG 112, of which most students were required to take at least one to earn a degree or certification. After consulting with faculty, the researchers designed two workshops for each course that integrated active and group learning techniques. The ENG 111 workshops covered pre-searching (e.g., mind mapping and selecting search terms and database searching in the first session, and website analysis and research (e.g., URLs, Google’s advanced search, and the evaluative CRAAP test in the second session. The ENG 112 workshops covered subject database searching in the first session and evaluative analysis of magazine and scholarly journal articles in the second session. Instructors provided web-based tutorials to online course sections as a substitute for the face-to-face sessions. Course assignments were the same for both online and face-to-face classes. The researchers used anonymous online surveys. ENG 111 students completed pre-test and post-test surveys for their two workshops during the fall 2014 semester. The surveys consisted of seven fill-in-the-blank and multiple-choice questions measuring pre

  10. The Influence of Intersections on Fuel Consumption in Urban Arterial Road Traffic: A Single Vehicle Test in Harbin, China.

    Directory of Open Access Journals (Sweden)

    Lina Wu

    Full Text Available The calculating method for fuel consumption (FC was put forward and calibrated and the characteristics of the fuel consumption on intersections were analyzed based on 18 groups of vehicular operating data which were acquired from the test experiment of a single vehicle along the urban arterial roads in Harbin, China. The results obtained show that 50.36% of the fuel consumption for the test vehicle was used at the area of intersections compared with 28.9% of the influencing distance and 68.5% of the running time; and 78.4% of them was burnt at the stages of acceleration and idling. Meanwhile, the type

  11. Clinical value of single versus composite provocative clinical tests in the assessment of painful shoulder.

    Science.gov (United States)

    Salaffi, Fausto; Ciapetti, Alessandro; Carotti, Marina; Gasparini, Stefania; Filippucci, Emilio; Grassi, Walter

    2010-04-01

    The aims of the present study were to investigate the clinical value of the provocative clinical tests and propose a composite index for the assessment of painful shoulder, using ultrasonography (US) as reference method. Two hundred three patients with painful shoulder underwent both clinical and US evaluations. The physical examination was carried out performing the Hawkins, Jobe, Patte, Gerber, and Speed tests. Each test was included in a composite index namely, SNAPSHOT (Simple Numeric Assessment of Pain by SHOulder Tests). The US examination was performed by a rheumatologist experienced in US and blinded to clinical findings. Sensitivity, specificity, positive and negative predictive values, positive and negative likelihood ratio of each clinical test were calculated. The receiver operating characteristic (ROC) curve analysis was used to assess the performance of the composite SNAPSHOT index. Sensitivity was low for the clinical diagnosis of all shoulder abnormalities. The highest sensitivity and smallest negative likelihood ratio were found for the Hawkins (63.88% and 0.50%) and Patte (62.21% and 0.52%) tests. Specificity was good for Speed (76.33%), Gerber (75.42%), and Patte (74.20%) tests. Patte and Speed tests were the most accurate (71.12% and 66.41%, respectively). The calculated area under the ROC curve related to the SNAPSHOT composite index was 0.881 +/- 0.026. With an optimal cut-off point of 3, the sensitivity and specificity were 75.8% and 87.5%, respectively. The results of the present study showed that SNAPSHOT is a feasible, informative and quantitative composite index for the assessment of painful shoulder in the clinical setting.

  12. Standardized testing with chlorhexidine in perioperative allergy--a large single-centre evaluation.

    Science.gov (United States)

    Opstrup, M S; Malling, H-J; Krøigaard, M; Mosbech, H; Skov, P S; Poulsen, L K; Garvey, L H

    2014-10-01

    Perioperative allergic reactions to chlorhexidine are often severe and easily overlooked. Although rare, the prevalence remains unknown. Correct diagnosis is crucial, but no validated provocation model exists, and other diagnostic tests have never been evaluated. The aims were to estimate (i) the prevalence of chlorhexidine allergy in perioperative allergy and (ii) the specificity and sensitivity for diagnostic tests for chlorhexidine allergy. We included all patients investigated for suspected perioperative allergic reactions in the Danish Anaesthesia Allergy Centre during 2004-2012. The following tests were performed: specific IgE (Immunocap® ; Phadia AB, Sweden), histamine release test (HR) (RefLab ApS, Denmark), skin prick test (SPT) and intradermal test (IDT). Positivity criteria were as follows: specific IgE >0.35 kUA/l; HR class 1-12; SPT mean wheal diameter ≥3 mm; IDT mean wheal diameter ≥ twice the diameter of negative control. Chlorhexidine allergy was post hoc defined as a relevant clinical reaction to chlorhexidine combined with two or more positive tests. Based on this definition, sensitivity and specificity were estimated for each test. In total, 22 of 228 patients (9.6%) met the definition of allergy to chlorhexidine. Estimated sensitivity and specificity were as follows: specific IgE (sensitivity 100% and specificity 97%), HR (sensitivity 55% and specificity 99%), SPT (sensitivity 95% and specificity 97%) and IDT (sensitivity 68% and specificity 100%). In patients investigated for suspected perioperative allergic reactions, 9.6% were diagnosed with allergy to chlorhexidine. Using our definition of chlorhexidine allergy, the highest combined estimated sensitivity and specificity was found for specific IgE and SPT. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  13. Study on Single-yarn Pullout Test of Ballistic Resistant Fabric under Different Preloads

    Science.gov (United States)

    Fang, Q. C.; Lei, Z. K.; Y Qin, F.; Li, W. K.; Bai, R. X.

    2017-12-01

    During bullet penetrating fabric, the pull-out force of yarn in fabric is related to the impact resistance of fabric when the yarn is pulled out from the fabric. The complex uncrimping and friction slip behavior occur during the yarn pullout process, which is critical to learn the impact resistance of fabric. Based on digital image correlation technique, the deformation behavior of Kevlar 49 fabric subjected to preload during the single-yarn pullout process was studied in this paper. The pullout force and displacement curve shows a straight rise and an oscillated decrease. In the linear rise stage, the yarn uncrimping causes a static friction effect. The maximum of the pullout force is not linearly increased with the preload. In the oscillating descending stage, the local descent of the pullout force indicates that the yarn end is gradually withdrawn from the fabric, and the local rise indicates that the yarn end moves to the next weft/warp interaction until the yarn is completely pulled out. The shear deformation of fabric corresponds to the single-yarn pullout process.

  14. Standard practice for measurement of the glass dissolution rate using the single-pass flow-through test method

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This practice describes a single-pass flow-through (SPFT) test method that can be used to measure the dissolution rate of a homogeneous silicate glass, including nuclear waste glasses, in various test solutions at temperatures less than 100°C. Tests may be conducted under conditions in which the effects from dissolved species on the dissolution rate are minimized to measure the forward dissolution rate at specific values of temperature and pH, or to measure the dependence of the dissolution rate on the concentrations of various solute species. 1.2 Tests are conducted by pumping solutions in either a continuous or pulsed flow mode through a reaction cell that contains the test specimen. Tests must be conducted at several solution flow rates to evaluate the effect of the flow rate on the glass dissolution rate. 1.3 This practice excludes static test methods in which flow is simulated by manually removing solution from the reaction cell and replacing it with fresh solution. 1.4 Tests may be conducted wit...

  15. Multiparty Session Types as Coherence Proofs

    DEFF Research Database (Denmark)

    Carbone, Marco; Montesi, Fabrizio; Schürmann, Carsten

    2015-01-01

    We propose a Curry-Howard correspondence between a language for programming multiparty sessions and a generalisation of Classical Linear Logic (CLL). In this framework, propositions correspond to the local behaviour of a participant in a multiparty session type, proofs to processes, and proof nor...... in a multiparty session. We prove the soundness of our model by showing the admissibility of our new rule, which entails deadlock-freedom via our correspondence....

  16. Secure Execution of Distributed Session Programs

    Directory of Open Access Journals (Sweden)

    Nuno Alves

    2011-10-01

    Full Text Available The development of the SJ Framework for session-based distributed programming is part of recent and ongoing research into integrating session types and practical, real-world programming languages. SJ programs featuring session types (protocols are statically checked by the SJ compiler to verify the key property of communication safety, meaning that parties engaged in a session only communicate messages, including higher-order communications via session delegation, that are compatible with the message types expected by the recipient. This paper presents current work on security aspects of the SJ Framework. Firstly, we discuss our implementation experience from improving the SJ Runtime platform with security measures to protect and augment communication safety at runtime. We implement a transport component for secure session execution that uses a modified TLS connection with authentication based on the Secure Remote Password (SRP protocol. The key technical point is the delicate treatment of secure session delegation to counter a previous vulnerability. We find that the modular design of the SJ Runtime, based on the notion of an Abstract Transport for session communication, supports rapid extension to utilise additional transports whilst separating this concern from the application-level session programming task. In the second part of this abstract, we formally prove the target security properties by modelling the extended SJ delegation protocols in the pi-calculus.

  17. An evaluation testing technique of single event effect using Beam Blanking SEM

    Energy Technology Data Exchange (ETDEWEB)

    Aoki, J.; Hada, T.; Pesce, A.; Akutsu, T.; Matsuda, S. [National Space Development Agency of Japan, Tsukuba, Ibaraki (Japan). Tsukuba Space Center; Igarashi, T.; Baba, S.

    1997-03-01

    Beam Blanking SEM (Scanning Electron Microscope) testing technique has been applied to CMOS SRAM devices to evaluate the occurence of soft errors on memory cells. Cross-section versus beam current and LET curves derived from BBSEM and heavy ion testing technique, respectively, have been compared. A linear relation between BBSEM current and heavy ion LET has been found. The purpose of this study was to demonstrate that the application of focused pulsed electron beam could be a reliable, convenient and inexpensive tool to investigate the effects of heavy ions and high energy particles on memory devices for space application. (author)

  18. Histocompatibility Testing for Organ Transplantation Purposes in Albania: A Single Center Experience

    Directory of Open Access Journals (Sweden)

    Erkena Shyti

    2014-06-01

    Full Text Available Background: Histocompatibility testing (HT which includes donor-recipient human leukocyte antigen (HLA matching, cross-match testing (XMT and anti-HLA antibody searching are crucial examinations in solid organ transplantation aiming to avoid the hyperacute graft rejection and also to predict the immunological outcome of the graft. Aims: The aim of this study was to analyse the tissue typing data collected at the Laboratory of Immunology and Histocompatibility of the University Hospital Center of Tirana, Albania, in order to define those actions that should be taken for improvements in the situation of kidney transplantation in Albania. Design: Descriptive study. Methods: The donor/recipient cross-match testing was performed through a standard complement-dependent cytotoxicity (CDC assay using separated donor T and B cells that were tested in parallel with the recipient serum sample. All recipient sera were screened for anti-Class I and anti-Class II HLA antibodies using a bead based Luminex anti-HLA antibody screening test. In the case of detected positivity, an allele-specific anti-HLA antibody determination was conducted with the respective Luminex anti-Class I and Class II HLA antibody determination kits. Results: A total of 174 recipients and 202 donors were typed for the purpose of living donor kidney transplantation at our laboratory between January 2006 and December 2012. The mean age and female gender proportion of patients were 34.9 years and 34.5%, respectively, and 48.0 years and 65.3% for the donors, respectively. Here, 25.9% of the patients reported a positive complement-dependent cytotoxicity cross-match test and/or a positive anti-HLA antibody testing result. Eighteen patients that were negative for the complement-dependent cytotoxicity cross-match test were positive for anti-HLA antibodies. Conclusion: The predominant causes of end-stage renal disease (ESRD in our patient population are chronic pyelonephritis and

  19. Improving preimplantation genetic diagnosis for Fragile X syndrome: two new powerful single-round multiplex indirect and direct tests.

    Science.gov (United States)

    Kieffer, Emmanuelle; Nicod, Jean-Christophe; Gardes, Nathalie; Kastner, Claire; Becker, Nicolas; Celebi, Catherine; Pirrello, Olivier; Rongières, Catherine; Koscinski, Isabelle; Gosset, Philippe; Moutou, Céline

    2016-02-01

    Fragile X syndrome (FraX) is caused by the expansion of an unstable CGG repeat located in the Fragile X mental retardation 1 gene (FMR1) gene. Preimplantation genetic diagnosis (PGD) can be proposed to couples at risk of transmitting the disease, that is, when the female carries a premutation or a full mutation. We describe two new single-cell, single-round multiplex PCR for indirect and direct diagnosis of FraX on biopsied embryos. These tests include five unpublished, highly heterozygous simple sequence repeats, and the co-amplification of non-expanded CGG repeats for the direct test. Heterozygosity of the new markers ranged from 69 to 81%. The mean rate of non-informative marker included in the tests was low (26% and 23% for the new indirect and direct tests, respectively). This strategy allows offering a PGD for FraX to 96% of couples requesting it in our centre. A conclusive genotype was obtained in all cells with a rate of cells presenting an allele dropout ranging from 17% for the indirect test to 26% for the direct test. The new indirect test was applied for eight PGD cycles: 32 embryos were analysed, 9 were transferred and 3 healthy babies were born. By multiplexing these highly informative markers, robustness of the diagnosis is improved and the loss of potentially healthy embryos (because they are non-diagnosed or misdiagnosed) is limited. This may increase the chances of success of couples requesting a PGD for FraX, in particular, when premature ovarian insufficiency in premutated women leads to a reduced number of embryos available for analysis.

  20. Single well thermal tracer test, a new experimental set up for characterizing thermal transport in fractured media

    Science.gov (United States)

    de La Bernardie, Jérôme; Bour, Olivier; Guihéneuf, Nicolas; Chatton, Eliot; Labasque, Thierry; Longuevergne, Laurent; Le Lay, Hugo; Koch, Floriant; Gerard, Marie-Françoise; Le Borgne, Tanguy

    2017-04-01

    Thermal transport in fractured media depends on the hydrological properties of fractures and thermal characteristics of rock. Tracer tests using heat as tracer can thus be a good alternative to characterize fractured media for shallow geothermal needs. This study investigates the possibility of implementing a new thermal tracer test set up, the single well thermal tracer test, to characterize hydraulic and thermal transport properties of fractured crystalline rock. The experimental setup is based on injecting hot water in a fracture isolated by a double straddle packer in the borehole while pumping and monitoring the temperature in a fracture crossing the same borehole at greater elevation. One difficulty comes from the fact that injection and withdrawal are achieved in the same borehole involving thermal losses along the injection tube that may disturb the heat recovery signal. To be able to well localize the heat influx, we implemented a Fiber-Optic Distributed Temperature Sensing (FO-DTS) which allows the temperature monitoring with high spatial and temporal resolution (29 centimeters and 30 seconds respectively). Several tests, at different pumping and injection rates, were performed in a crystalline rock aquifer at the experimental site of Ploemeur (H+ observatory network). We show through signal processing how the thermal breakthrough may be extracted thanks to Fiber-Optic distributed temperature measurements. In particular, we demonstrate how detailed distributed temperature measurements were useful to identify different inflows and to estimate how much heat was transported and stored within the fractures network. Thermal breakthrough curves of single well thermal tracer tests were then interpreted with a simple analytical model to characterize hydraulic and thermal characteristics of the fractured media. We finally discuss the advantages of these tests compared to cross-borehole thermal tracer tests.

  1. Study of single dose toxic test of Sweet Bee Venom in Beagle Dogs

    Directory of Open Access Journals (Sweden)

    Hye-Chul, Yoon

    2010-12-01

    Full Text Available Objectives : This study was performed to analyse single dose toxicity of Sweet Bee Venom(Sweet BV extracted from the bee venom in Beagle dogs. Methods : All experiments were conducted under the regulations of Good Laboratory Practice (GLP at Biotoxtech Company, a non-clinical study authorized institution. Male and female Beagle dogs of 5-6 months old were chosen for the pilot study of single dose toxicity of Sweet BV which was administered at the level of 9.0 ㎎/㎏ body weight which is 1300 times higher than the clinical application dosage as the high dosage, followed by 3.0 and 1.0 ㎎/㎏ as midium and low dosage, respectively. Equal amount of excipient(normal saline to the Sweet BV experiment groups was administered as the control group. Results : 1. No mortality was witnessed in all of the experiment groups. 2. Hyperemia and movement disorder were observed around the area of administration in all the experiment groups, and higher occurrence in the higher dosage treatment. 3. For weight measurement, Neither male nor female groups showed significant changes. 4. To verify abnormalities of organs and tissues, thigh muscle which treated with Sweet BV, brain, liver, lung, kidney, and spinal cords were removed and histologocal observation using H-E staining was conducted. In the histologocal observation of thigh muscle, cell infiltration, inflammation, degeneration, necrosis of muscle fiber, and fibrosis were found in both thigh tissue. And the changes depend on the dose of Sweet BV. But the other organs did not showed in any abnormality. 5. The maximum dose of Sweet BV in Beagle dogs were over 9 ㎎/㎏ in this study. Conclusions : The above findings of this study suggest that Sweet BV is a relatively safe treatment medium. Further studies on the toxicity of Sweet BV should be conducted to yield more concrete evidences.

  2. Screening Test Procedure For Long Life Single Mode Step Index Separate Confinement Heterostructure Single Quantum Well (Sinsch-Sqw) Laser Diodes

    Science.gov (United States)

    Fritz, William J.

    1989-06-01

    An experiment was conducted to establish an effective burn-in and screening procedure for long life SINSCH-SQW laser diodes. The laser diodes were grown by MOCVD and processed with 20μ wide oxide defined stripes. The devices had a high reflective back facet coating with a small etalon bonded to a passivated front facet to ensure single mode operation. The laser diodes were bonded p-side up to copper heat sinks using indium solder. A total of 48 devices were selected prior to burn-in and were operated at 200mA constant current for 2000 hours at an average heat sink temperature of 55°C. The average initial output power was 45mW per device. At the end of the test, the output powers ranged from lmW to 85mW. Most of the devices with the low final power failed catastrophically within 24 hours from the start of the test. Many laser diodes showed very little change in output power while others degraded gradually by varying amounts. Failure analysis showed that failures were facet, bulk, or heat sink related. The temporal output power degradations (i.e., gradual degradation, etc.) can be explained by the identified failure mechanisms. From the test results and failure analysis, a screening strategy based on inspection and burn-in can be devised to reject devices that may fail early. Also, improvements in processing can provide potential yield improvements. After accounting for degradation related to processing, a very long material lifetime is predicted for these SINSCH-SQW laser diodes.

  3. Six Single-Administration Reliability Coefficients for Criterion-Referenced Tests: A Comparative Study.

    Science.gov (United States)

    Downing, Steven M.; Mehrens, William A.

    Four criterion-referenced reliability coefficicents were compared to the Kuder-Richardson estimates and to each other. The Kuder-Richardson formulas 20 and 21, the Livingston, the Subkoviak and two Huynh coefficients were computed for a random sample of 33 criterion-referenced tests. The Subkoviak coefficient yielded the highest mean value;…

  4. Test-compatible confidence intervals for adaptive two-stage single-arm designs with binary endpoint.

    Science.gov (United States)

    Kunzmann, Kevin; Kieser, Meinhard

    2018-01-01

    Inference after two-stage single-arm designs with binary endpoint is challenging due to the nonunique ordering of the sampling space in multistage designs. We illustrate the problem of specifying test-compatible confidence intervals for designs with nonconstant second-stage sample size and present two approaches that guarantee confidence intervals consistent with the test decision. Firstly, we extend the well-known Clopper-Pearson approach of inverting a family of two-sided hypothesis tests from the group-sequential case to designs with fully adaptive sample size. Test compatibility is achieved by using a sample space ordering that is derived from a test-compatible estimator. The resulting confidence intervals tend to be conservative but assure the nominal coverage probability. In order to assess the possibility of further improving these confidence intervals, we pursue a direct optimization approach minimizing the mean width of the confidence intervals. While the latter approach produces more stable coverage probabilities, it is also slightly anti-conservative and yields only negligible improvements in mean width. We conclude that the Clopper-Pearson-type confidence intervals based on a test-compatible estimator are the best choice if the nominal coverage probability is not to be undershot and compatibility of test decision and confidence interval is to be preserved. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. Within- and between-session reliability of medial gastrocnemius architectural properties

    Directory of Open Access Journals (Sweden)

    JJ McMahon

    2016-05-01

    Full Text Available This study aimed to determine the within- and between-session reliability of medial gastrocnemius (MG architecture (e.g. muscle thickness (MT, fascicle length (FL and pennation angle (PA, as derived via ultrasonography followed by manual digitization. A single rater recorded three ultrasound images of the relaxed MG muscle belly for both legs of 16 resistance trained males, who were positioned in a pronated position with their knees fully extended and the ankles in a neutral (e.g. 90° position. A subset of participants (n = 11 were retested under the same conditions ~48-72 hours after baseline testing. The same rater manually digitized each ultrasound image on three occasions to determine MG MT, FL and PA before pooling the data accordingly to allow for within-image (n = 96, between-image (n = 32 and between-session reliability (n = 22 to be determined. Intraclass correlation coefficients (ICCs demonstrated excellent within-image (ICCs = 0.99-1.00, P < 0.001 and very good between-image (ICCs = 0.83-0.95, P < 0.001 and between-session (ICCs = 0.89- 0.95, P < 0.001 reliability for MT, FL and PA. Between-session coefficient of variation was low (≤ 3.6% for each architectural parameter and smallest detectible difference values of 10.6%, 11.4% and 9.8% were attained for MT, FL and PA, respectively. Manually digitizing ultrasound images of the MG muscle at rest yields highly reliable measurements of its architectural properties. Furthermore, changes in MG MT, FL and PA of ≥ 10.6%, 11.4% and 9.8% respectively, as brought about by any form of intervention, should be considered meaningful.

  6. Detailed session outputs by the groups

    International Nuclear Information System (INIS)

    2008-01-01

    methods are available to assess licensee safety culture, both formal (e.g. surveys, interviews) and informal (e.g. site inspector insights). - Regulatory staff should be given training to enable them to carry out safety culture interventions. - Regulators need to establish suitable internal regulatory processes and relationships to ensure effective sharing and use of safety culture information. - Current approaches to making a judgement on licensee safety culture are largely based on expert judgement, using data from a variety of sources. - There was general consensus that numerical rating of safety culture has limited meaning, especially a drive to a single number. - Building safety culture data collection into existing regulatory activities requires: commitment within the regulatory body, reflected in leadership, resources, and processes. - There was general agreement that interaction with licensees on safety culture issues should be not be fundamentally different to other regulatory areas. - To retain effective oversight of licensee safety culture it was agreed that regulators should provide an improved awareness of human and organizational factors/safety culture within the regulatory body, learn from other industries to avoid insularity, better integrate safety culture data collection into regulatory business, ensure long term follow up of issues and improve regulatory documentation. questions raised through the discussions as well as main points highlighted during the feedback session are listed

  7. Single venom-based immunotherapy effectively protects patients with double positive tests to honey bee and Vespula venom

    Science.gov (United States)

    2013-01-01

    Background Referring to individuals with reactivity to honey bee and Vespula venom in diagnostic tests, the umbrella terms “double sensitization” or “double positivity” cover patients with true clinical double allergy and those allergic to a single venom with asymptomatic sensitization to the other. There is no international consensus on whether immunotherapy regimens should generally include both venoms in double sensitized patients. Objective We investigated the long-term outcome of single venom-based immunotherapy with regard to potential risk factors for treatment failure and specifically compared the risk of relapse in mono sensitized and double sensitized patients. Methods Re-sting data were obtained from 635 patients who had completed at least 3 years of immunotherapy between 1988 and 2008. The adequate venom for immunotherapy was selected using an algorithm based on clinical details and the results of diagnostic tests. Results Of 635 patients, 351 (55.3%) were double sensitized to both venoms. The overall re-exposure rate to Hymenoptera stings during and after immunotherapy was 62.4%; the relapse rate was 7.1% (6.0% in mono sensitized, 7.8% in double sensitized patients). Recurring anaphylaxis was statistically less severe than the index sting reaction (P = 0.004). Double sensitization was not significantly related to relapsing anaphylaxis (P = 0.56), but there was a tendency towards an increased risk of relapse in a subgroup of patients with equal reactivity to both venoms in diagnostic tests (P = 0.15). Conclusions Single venom-based immunotherapy over 3 to 5 years effectively and long-lastingly protects the vast majority of both mono sensitized and double sensitized Hymenoptera venom allergic patients. Double venom immunotherapy is indicated in clinically double allergic patients reporting systemic reactions to stings of both Hymenoptera and in those with equal reactivity to both venoms in diagnostic tests who have not reliably identified the

  8. Full-Scale Crash Tests and Analyses of Three High-Wing Single

    Science.gov (United States)

    Annett, Martin S.; Littell, Justin D.; Stimson, Chad M.; Jackson, Karen E.; Mason, Brian H.

    2015-01-01

    The NASA Emergency Locator Transmitter Survivability and Reliability (ELTSAR) project was initiated in 2014 to assess the crash performance standards for the next generation of ELT systems. Three Cessna 172 aircraft have been acquired to conduct crash testing at NASA Langley Research Center's Landing and Impact Research Facility. Testing is scheduled for the summer of 2015 and will simulate three crash conditions; a flare to stall while emergency landing, and two controlled flight into terrain scenarios. Instrumentation and video coverage, both onboard and external, will also provide valuable data of airframe response. Full-scale finite element analyses will be performed using two separate commercial explicit solvers. Calibration and validation of the models will be based on the airframe response under these varying crash conditions.

  9. Testing Single and Combinations of Amendments for Stabilization of Metals in Contrasting Extremely Contaminated Soils

    Directory of Open Access Journals (Sweden)

    Siebielec G.

    2013-04-01

    Full Text Available Metals can be stabilized by soil amendments that increase metals adsorption or alter their chemical forms. Such treatments may limit the risk related to the contamination through reduction of metal transfer to the food chain (reduction of metal uptake by plants and its availability to soil organisms and metals migration within the environment. There is a need for experiments comparing various soil amendments available at reasonable amounts under similar environmental conditions. The other question is whether all components of soil environment or soil functions are similarly protected after remediation treatment. We conducted a series of pot studies to test some traditional and novel amendments and their combinations. The treatments were tested for several highly Zn/Cd/Pb contaminated soils. Among traditional amendments composts were the most effective – they ensured plant growth, increased soil microbial activity, reduced Cd in earthworms, reduced Pb bioaccessibility and increased share of unavailable forms of Cd and Pb.

  10. Photovoltaic power system tests on an 8-kilowatt single-phase line-commutated inverter

    Science.gov (United States)

    Stover, J. B.

    1978-01-01

    Efficiency and power factor were measured as functions of solar array voltage and current. The effects of input shunt capacitance and series inductance were determined. Tests were conducted from 15 to 75 percent of the 8 kW rated inverter input power. Measured efficiencies ranged from 76 percent to 88 percent at about 50 percent of rated inverter input power. Power factor ranged from 36 percent to 72 percent.

  11. Design of a single flat null-screen for testing a parabolic trough solar collector

    Science.gov (United States)

    Moreno-Oliva, Víctor Iván; Campos-García, Manuel; Román-Hernández, Edwin; Santiago-Alvarado, Agustín

    2014-11-01

    We present a null-screen design for testing the shape quality of the reflecting surface of a parabolic trough solar collector (PTSC). This technique is inexpensive, the whole surface is tested at once, and it is easy to implement. For this, we propose the design of a flat null-screen perpendicular to the optical axis of the PTSC in such a way that it allows testing of the full aperture; we compute the caustic associated with the reflected light rays on the desired surface and analyze the parameters that determine the null-screen dimensions. Additionally, we perform a numerical simulation to analyze the accuracy of the method by introducing random displacement errors into the measured data. Accuracies >0.35 mrad were found to evaluate the quality of surfaces with this method. The errors in the determination of the coordinates of the centroids of the reflected images must be measured with an accuracy >0.5 pixels, and the errors in the coordinates of the spots of the null-screen must be <0.5 mm.

  12. 3D Imaging with a Single-Aperture 3-mm Objective Lens: Concept, Fabrication and Test

    Science.gov (United States)

    Korniski, Ron; Bae, Sam Y.; Shearn, Mike; Manohara, Harish; Shahinian, Hrayr

    2011-01-01

    There are many advantages to minimally invasive surgery (MIS). An endoscope is the optical system of choice by the surgeon for MIS. The smaller the incision or opening made to perform the surgery, the smaller the optical system needed. For minimally invasive neurological and skull base surgeries the openings are typically 10-mm in diameter (dime sized) or less. The largest outside diameter (OD) endoscope used is 4mm. A significant drawback to endoscopic MIS is that it only provides a monocular view of the surgical site thereby lacking depth information for the surgeon. A stereo view would provide the surgeon instantaneous depth information of the surroundings within the field of view, a significant advantage especially during brain surgery. Providing 3D imaging in an endoscopic objective lens system presents significant challenges because of the tight packaging constraints. This paper presents a promising new technique for endoscopic 3D imaging that uses a single lens system with complementary multi-bandpass filters (CMBFs), and describes the proof-of-concept demonstrations performed to date validating the technique. These demonstrations of the technique have utilized many commercial off-the-shelf (COTS) components including the ones used in the endoscope objective.

  13. Single-photon test of hyper-complex quantum theories using a metamaterial.

    Science.gov (United States)

    Procopio, Lorenzo M; Rozema, Lee A; Wong, Zi Jing; Hamel, Deny R; O'Brien, Kevin; Zhang, Xiang; Dakić, Borivoje; Walther, Philip

    2017-04-21

    In standard quantum mechanics, complex numbers are used to describe the wavefunction. Although this has so far proven sufficient to predict experimental results, there is no theoretical reason to choose them over real numbers or generalizations of complex numbers, that is, hyper-complex numbers. Experiments performed to date have proven that real numbers are insufficient, but the need for hyper-complex numbers remains an open question. Here we experimentally probe hyper-complex quantum theories, studying one of their deviations from complex quantum theory: the non-commutativity of phases. We do so by passing single photons through a Sagnac interferometer containing both a metamaterial with a negative refractive index, and a positive phase shifter. To accomplish this we engineered a fishnet metamaterial to have a negative refractive index at 780 nm. We show that the metamaterial phase commutes with other phases with high precision, allowing us to place limits on a particular prediction of hyper-complex quantum theories.

  14. H.R. 1794: This Act may be cited as the Radon Testing for Safe Schools Act of 1991, introduced in the US House of Representatives, One Hundred Second Congress, First Session, April 16, 1991

    International Nuclear Information System (INIS)

    Anon.

    1991-01-01

    Studies by the Environmental Protection Agency indicate that 54% of schools tested have at least one room with elevated levels of radon and that over 20% of all school rooms tested have elevated levels of radon. This bill was introduced into the US House of Representatives on April 16, 1991 to provide for the testing and remediation of radon contamination in school buildings. Key features of this legislation revolve around the following: requirements for radon testing in schools; and radon in schools remediation grant assistance

  15. Ann Arbor Session I: Breaking Ground.

    Science.gov (United States)

    Music Educators Journal, 1979

    1979-01-01

    Summarizes the first session of the National Symposium on the Applications of Psychology to the Teaching and Learning of Music held at Ann Arbor from October 30 to November 2, 1978. Sessions concerned auditory perception, motor learning, child development, memory and information processing, and affect and motivation. (SJL)

  16. Summary of southeastern group breakout sessions

    Science.gov (United States)

    Bob Ford; Charles P. Nicholson

    1993-01-01

    The breakout sessions held by the southeastern representatives at the Partners In Flight meeting in Colorado were extremely well attended Most states were represented, as well as several federal agencies (including USFS, USFWS, TVA, EPA), and non-government organizations. Two sessions were held, one to discuss a strategy of management by...

  17. Multiparty session types as coherence proofs

    DEFF Research Database (Denmark)

    Carbone, Marco; Montesi, Fabrizio; Schürmann, Carsten

    2017-01-01

    We propose a Curry–Howard correspondence between a language for programming multiparty sessions and a generalisation of Classical Linear Logic (CLL). In this framework, propositions correspond to the local behaviour of a participant in a multiparty session type, proofs to processes, and proof nor...

  18. Summary of the session on other effects

    International Nuclear Information System (INIS)

    Chao, A.

    1997-07-01

    The theme of this workshop is to discuss the effects of foreign particles on the native beam in a storage ring. This paper summarizes the session on effects not covered in sessions on fast ion instability, electron cloud instability, and cures. The topics discussed are the beam, the foreign particle, how are foreign particles trapped, and how do foreign particles and beam couple

  19. Summary of sessions on experimental facilities

    International Nuclear Information System (INIS)

    Arvieux, J.; Walcher, T.

    1991-01-01

    The contributions and discussions on the session Present Status and Future Perspectives in the Experimental Activities are summarized. In this session the points of convergence and the complementarity for the study of Few Body Systems with strong and electromagnetic probes were apparent. This aspect is emphasized

  20. Client Introversion and Counseling Session Impact.

    Science.gov (United States)

    Nocita, Andrew; Stiles, William B.

    1986-01-01

    Examined impact of counseling sessions as a function of clients' personality characteristics. Results indicated introverted clients rated their sessions as uncomfortable, unpleasant, tense, rough, and difficult and rated their postsession mood as relatively unfriendly, uncertain, sad, angry, and afraid. Conversely, extroverted clients rated their…

  1. Secure Implementations for Typed Session Abstractions

    NARCIS (Netherlands)

    Corin, R.J.; Deniélou, Pierre-Malo; Fournet, Cédric; Bhargavan, Karthikeyan; Leifer, James; Focardi, R.

    Distributed applications can be structured as parties that exchange messages according to some pre-arranged communication patterns. These sessions (or contracts, or protocols) simplify distributed programming: when coding a role for a given session, each party just has to follow the intended message

  2. Factors Influencing Number of Physiotherapy Treatment Sessions ...

    African Journals Online (AJOL)

    Little is known about the influence of physiotherapists' characteristics and treatment modalities on the number of treatment sessions in Nigeria. This study was designed to evaluate the factors influencing the number of treatment sessions for patients with low back pain (LBP). Three hundred and eleven practising ...

  3. Spanning a multimedia session across multiple devices

    NARCIS (Netherlands)

    Aartse Tuijn, Jasper; Bijwaard, D.

    2008-01-01

    This paper describes an innovative solution that allows a multimedia session to be distributed over multiple devices that are in close proximity to a user. This would typically be useful when a user engaged in an audio/video conference enters a meeting room. Upon entering, all media session

  4. Merging single-well and inter-well tracer tests into one forced-gradient dipole test, at the Heletz site within the MUSTANG project

    Science.gov (United States)

    Behrens, Horst; Ghergut, Julia; Bensabat, Jac; Niemi, Auli; Licha, Tobias; Ptak, Thomas; Sauter, Martin

    2014-05-01

    The Heletz site[1] in Israel was chosen for conducting a CO2 transport experiment within the MUSTANG project[2], whose aim is to demonstrate and validate leading-edge techniques for CCS site characterization, process monitoring and risk assessment. The major CO2 injection experiment at Heletz was supposed to be preceded and accompanied by a sequence of single-well 'push-then-pull' (SW) and inter-well (IW) tracer tests, aimed at characterizing transport properties of the storage formation, in accordance to a number of general and specific principles[3],[4]. - Instead of the rather luxurious {SW1, IW1, SW2, IW2} test sequence described in our previous work[5], we now propose a drastically economized tracer test concept, which lets the sampling stages of SW and IW tests merge into a single fluid production stage, and relies on a forced-gradient dipole flow field at any time of the overall test. Besides cost reduction, this economized design also improves on operational aspects, as well as on issues of parameter ambiguity and of scale disparity between SW and IW flow fields: (i) the new design renders SW test results more representative for the aquifer sector ('angle') actually interrogated by the IW dipole test; (ii) the new design saves time and costs on the SW test (fluid sampling for SW 'pull' now being conducted simultaneously with IW-related sampling and monitoring), while allowing for a considerably longer duration of SW 'pull' signals than had originally been intended, whose late-time tailings help improve the quantification of non-advective processes and parameters, which are of great relevance to mid- and long-term trapping mechanisms ('residual trapping', 'mineral trapping'); (iii) the quasi-simultaneous execution of fluid injection/production for the IW and SW tests considerably reduces the overall hydraulic imbalance that was originally associated with the SW test, thus preventing formation damage and supporting hydrogeomechanical stability; (iv) the new

  5. Standard test method for isotopic analysis of uranium hexafluoride by double standard single-collector gas mass spectrometer method

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This is a quantitative test method applicable to determining the mass percent of uranium isotopes in uranium hexafluoride (UF6) samples with 235U concentrations between 0.1 and 5.0 mass %. 1.2 This test method may be applicable for the entire range of 235U concentrations for which adequate standards are available. 1.3 This test method is for analysis by a gas magnetic sector mass spectrometer with a single collector using interpolation to determine the isotopic concentration of an unknown sample between two characterized UF6 standards. 1.4 This test method is to replace the existing test method currently published in Test Methods C761 and is used in the nuclear fuel cycle for UF6 isotopic analyses. 1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appro...

  6. Summary of Technical Sessions - Summary and Recommendations

    International Nuclear Information System (INIS)

    2013-01-01

    Technical Session 1 - Development achievements of BEPU methods and State of the Art: The objective of this session was to present the different approaches dealing with Best Estimate codes and uncertainties evaluations. Existing methods were summarized and different papers were focused on specific methods stressing their bases, peculiarities, advantages and limitations. As a result of the session a picture of the current State of the Art was obtained. The session comprised six papers. Technical Session 2 - International comparative activities: This session had as a main objective to review the activities launched in the past and present from the NEA in connection with BEPU methods, with focus on the applicability of conclusions derived from former benchmarks like UMS, the main outcomes of the recently finished BEMUSE project, and the objectives and relevance of UAM and PREMIUM projects. The session comprised four papers. Technical Session 3 - Applications: Licensing, safety analysis support, regulatory body views and industry activities: This session focused on the application of current methods in safety analyses. Contributions from industry, technical safety organizations and regulatory bodies were provided. As a result, a view of the penetration of BEPU methods in current safety analyses was obtained, as well as an indication of the evolution in the near future. Elements such as licensing practices, assessment process, etc. were considered. The session comprised nine papers. Technical Session 4. BEPU methods extension to new fields The session addressed the extension of BEPU methods beyond their current use. By now such methods are mainly applied to classic deterministic environment but it is believed that their benefits could be extended to other fields. Seven papers were presented in the session dealing with subjects that fit in the objectives established in the workshop programme. The papers cover areas like: extension to CFD, quantification of global safety

  7. Reverse-Transcriptase PCR Detection of Leptospira: Absence of Agreement with Single-Specimen Microscopic Agglutination Testing.

    Science.gov (United States)

    Waggoner, Jesse J; Balassiano, Ilana; Mohamed-Hadley, Alisha; Vital-Brazil, Juliana Magalhães; Sahoo, Malaya K; Pinsky, Benjamin A

    2015-01-01

    Reference diagnostic tests for leptospirosis include nucleic acid amplification tests, bacterial culture, and microscopic agglutination testing (MAT) of acute and convalescent serum. However, clinical laboratories often do not receive paired specimens. In the current study, we tested serum samples using a highly sensitive real-time nucleic acid amplification test for Leptospira and compared results to MAT performed on the same specimens. 478 serum samples from suspected leptospirosis cases in Rio de Janeiro were tested using a real-time RT-PCR for the diagnosis of leptospirosis, malaria and dengue (the Lepto-MD assay). The Lepto-MD assay detects all species of Leptospira (saprophytic, intermediate, and pathogenic), and in the current study, we demonstrate that this assay amplifies both Leptospira RNA and DNA. Dengue virus RNA was identified in 10 patients, and no cases of malaria were detected. A total of 65 samples (13.6%) were positive for Leptospira: 35 samples (7.3%) in the Lepto-MD assay, 33 samples (6.9%) by MAT, and 3 samples tested positive by both (kappa statistic 0.02). Poor agreement between methods was consistent regardless of the titer used to define positive MAT results or the day of disease at sample collection. Leptospira nucleic acids were detected in the Lepto-MD assay as late as day 22, and cycle threshold values did not differ based on the day of disease. When Lepto-MD assay results were added to the MAT results for all patients in 2008 (n=818), the number of detected leptospirosis cases increased by 30.4%, from 102 (12.5%) to 133 (16.3%). This study demonstrates a lack of agreement between nucleic acid detection of Leptospira and single-specimen MAT, which may result from the clearance of bacteremia coinciding with the appearance of agglutinating antibodies. A combined testing strategy for acute leptospirosis, including molecular and serologic testing, appears necessary to maximize case detection.

  8. Using session types as an effect system

    Directory of Open Access Journals (Sweden)

    Dominic Orchard

    2016-02-01

    Full Text Available Side effects are a core part of practical programming. However, they are often hard to reason about, particularly in a concurrent setting. We propose a foundation for reasoning about concurrent side effects using sessions. Primarily, we show that session types are expressive enough to encode an effect system for stateful processes. This is formalised via an effect-preserving encoding of a simple imperative language with an effect system into the pi-calculus with session primitives and session types (into which we encode effect specifications. This result goes towards showing a connection between the expressivity of session types and effect systems. We briefly discuss how the encoding could be extended and applied to reason about and control concurrent side effects.

  9. Deck and Cable Dynamic Testing of a Single-span Bridge Using Radar Interferometry and Videometry Measurements

    Science.gov (United States)

    Piniotis, George; Gikas, Vassilis; Mpimis, Thanassis; Perakis, Harris

    2016-03-01

    This paper presents the dynamic testing of a roadway, single-span, cable-stayed bridge for a sequence of static load and ambient vibration monitoring scenarios. Deck movements were captured along both sideways of the bridge using a Digital Image Correlation (DIC) and a Ground-based Microwave Interfererometer (GBMI) system. Cable vibrations were measured at a single point location on each of the six cables using the GBMI technique. Dynamic testing involves three types of analyses; firstly, vibration analysis and modal parameter estimation (i. e., natural frequencies and modal shapes) of the deck using the combined DIC and GBMI measurements. Secondly, dynamic testing of the cables is performed through vibration analysis and experimental computation of their tension forces. Thirdly, the mechanism of cable-deck dynamic interaction is studied through their Power Spectra Density (PSD) and the Short Time Fourier Transform (STFT) analyses. Thereby, the global (deck and cable) and local (either deck or cable) bridge modes are identified, serving a concrete benchmark of the current state of the bridge for studying the evolution of its structural performance in the future. The level of synergy and complementarity between the GBMI and DIC techniques for bridge monitoring is also examined and assessed.

  10. Innovation design of beta test loop system for heat transfer experiments in single-phase and two-phase flows

    International Nuclear Information System (INIS)

    Kiswanta; Edy Sumarno; Joko Prasetio W; Ainur Rosidi; G B Heru K

    2013-01-01

    Innovation design of BETA test loop has been done. BETA test loop is a research facility used as a support for experiments of reactor accident simulation. The innovation was performed to prepare experimental facilities in order to study flow of heat transfer in single-phase and two-phase flows. The design was executed by modifying new piping of UUB's primary system, addition of heat flux measurements and imaging thermal for easiness of experimental result analysis. UUB development and experiments were carried out to understand heat transfer process in the narrow gap of two-phase flow considering this phenomenon is one of the conditions postulated in PWR typed nuclear power plant accident scenario. The innovation design of BETA test loop is still in the planning stages so that the design has not been constructed. Piping systems made of SS-304 with the ability to use a maximum pressure of 10 bar with a diameter of % inch pipe to, from the calculation of minimal design that is 7.27 mm. If the tube SS-304 - ASTM B88 is the wall thickness of 0.083 inches. From this design it is indicated that the design is able to be fabricated and used for experimental study of heat transfer in single-phase and two-phase flows. (author)

  11. Use of single-well tracer dilution tests to evaluate LNAPL flux at seven field sites.

    Science.gov (United States)

    Mahler, Nicholas; Sale, Tom; Smith, Tim; Lyverse, Mark

    2012-01-01

    Petroleum liquids, referred to as light non-aqueous phase liquids (LNAPLs), are commonly found beneath petroleum facilities. Concerns with LNAPLs include migration into clean soils, migration beyond property boundaries, and discharges to surface water. Single-well tracer dilution techniques were used to measure LNAPL fluxes through 50 wells at 7 field sites. A hydrophobic tracer was mixed into LNAPL in a well. Intensities of fluorescence associated with the tracer were measured over time using a spectrometer and a fiber optic cable. LNAPL fluxes were estimated using observed changes in the tracer concentrations over time. Measured LNAPL fluxes range from 0.006 to 2.6 m/year with a mean and median of 0.15 and 0.064 m/year, respectively. Measured LNAPL fluxes are two to four orders of magnitude smaller than a common groundwater flux of 30 m/year. Relationships between LNAPL fluxes and possible governing parameters were evaluated. Observed LNAPL fluxes are largely independent of LNAPL thickness in wells. Natural losses of LNAPL through dissolution, evaporation, and subsequent biodegradation, were estimated using a simple mass balance, measured LNAPL fluxes in wells, and an assumed stable LNAPL extent. The mean and median of the calculated loss rates were found to be 24.0 and 5.0 m3/ha/year, respectively. Mean and median losses are similar to values reported by others. Coupling observed LNAPL fluxes to observed rates of natural LNAPL depletion suggests that natural losses of LNAPL may be an important parameter controlling the overall extent of LNAPL bodies.

  12. Status of High Power Tests of Normal Conducting Single-Cell Standing Wave Structures

    Energy Technology Data Exchange (ETDEWEB)

    Dolgashev, Valery; /SLAC; Tantawi, Sami; /SLAC; Yeremian, Anahid; /SLAC; Higashi, Yasuo; /KEK, Tsukuba; Spataro, Bruno; /INFN, Rome

    2012-06-25

    Our experiments are directed toward the understanding of the physics of rf breakdown in systems that can be used to accelerate electron beams at {approx}11.4 GHz. The structure geometries have apertures, stored energy per cell, and rf pulse duration close to that of the NLC or CLIC. The breakdown rate is the main parameter that we use to compare rf breakdown behavior for different structures at a given set of rf pulse parameters (pulse shape and peak power) at 60 Hz repetition rate. In our experiments, the typical range of the breakdown rate is from one per few hours to {approx}100 per hour. To date we have tested 29 structures. We consistently found that after the initial conditioning, the behavior of the breakdown rate is reproducible for structures of the same geometry and material, and the breakdown rate dependence on peak magnetic fields is stronger than on peak surface electric fields for structures of different geometries. Below we report the main results from tests of seven structures made from hard copper, soft copper alloys and hard-copper alloys. Additional details on these and other structures will be discussed in future publications.

  13. Assessing Potential Impacts of CO2 Leakage on Shallow Groundwater Quality in the SECARB Phase III Early Test site Using Single-well Push-Pull Tests

    Science.gov (United States)

    Yang, C.; Mickler, P. J.; Reedy, R. C.; Scanlon, B. R.

    2012-12-01

    A single-well push-pull test was conducted in the Cranfield shallow aquifer, the SECARB Phase III early test site, for assessing potential impacts of CO2 leakage on groundwater quality. A total of 3800 liter of groundwater equilibrated with CO2 gas at a partial pressure of 1.105 Pa was injected into a confined sand interval at ~ 70 m depth. NaBr solution was added to the injected solution as tracer. The injected groundwater incubated within the interval for about two days. Chemical parameters (pH, temperature, alkalinity, and electric conductivity) were measured on-site and water samples were collected for chemical (major ions, trace elements, and dissolved inorganic carbon, DIC) as well as for stable carbon isotopic analyses. Mineralogical analyses using XR-D and SEM techniques indicate that aquifer sediments are dominated by silicates. Concentrations of the Br tracer in the recovered samples show mixing of background water with the injected solution. Major ions, especially, Ca, Mg, K, and Si show obvious enrichment, indicating that mobilization of these ions occurred from aquifer sediments to groundwater and may be dominated by dissolution of silicates and possible carbonate minerals. δ13C of DIC of the recovered samples may also suggest potential dissolution of carbonates. Concentrations of trace elements show mobilization after injection of CO2 enriched groundwater. Mobilization of trace elements could be due to co-dissolution of silicates and carbonates and desorption from the surface of aquifer sediments. However, mass balance calculations suggest that ion mobilization is limited and; therefore, potential risks of CO2 are low, especially for arsenic and lead with concentrations in the recovered samples ~30 times less than the EPA maximum contamination level. Results of the single-well push-pull test were also compared to a laboratory batch experiment of water-rock-CO2 interactions. Overall reaction rates of most ions estimated are higher in the batch

  14. USING SESSION RPE TO MONITOR DIFFERENT METHODS OF RESISTANCE EXERCISE

    Directory of Open Access Journals (Sweden)

    Alison D. Egan

    2006-06-01

    Full Text Available The purpose of this study was to compare session rating of perceived exertion for different resistance training techniques in the squat exercise. These techniques included traditional resistance training, super slow, and maximal power training. Fourteen college-age women (Mean ± SD; age = 22 ± 3 years; height = 1.68 ± 0. 07 m completed three experimental trials in a randomized crossover design. The traditional resistance training protocol consisted of 6 sets of 6 repetitions of squats using 80% of 1-RM. The super slow protocol consisted of 6 sets of 6 repetitions using 55% of 1-RM. The maximal power protocol consisted of 6 sets of 6 repetitions using 30% of 1-RM. Rating of perceived exertion (RPE measures were obtained following each set using Borg's CR-10 scale. In addition, a session RPE value was obtained 30 minutes following each exercise session. When comparing average RPE and session RPE, no significant difference was found. However, power training had significantly lower (p < 0.05 average and session RPE (4.50 ± 1.9 and 4.5 ± 2.1 compared to both super slow training (7.81 ± 1.75 and 7.43 ± 1.73 and traditional training (7.33 ± 1.52 and 7.13 ± 1.73. The results indicate that session RPE values are not significantly different from the more traditional methods of measuring RPE during exercise bouts. It does appear that the resistance training mode that is used results in differences in perceived exertion that does not relate directly to the loading that is used. Using session RPE provides practitioners with the same information about perceived exertion as the traditional RPE measures. Taking a single measure following a training session would appear to be much easier than using multiple measures of RPE throughout a resistance training workout. However, practitioners should also be aware that the RPE does not directly relate to the relative intensity used and appears to be dependent on the mode of resistance exercise that is used

  15. Tidal volume single breath washout of two tracer gases--a practical and promising lung function test.

    Science.gov (United States)

    Singer, Florian; Stern, Georgette; Thamrin, Cindy; Fuchs, Oliver; Riedel, Thomas; Gustafsson, Per; Frey, Urs; Latzin, Philipp

    2011-03-10

    Small airway disease frequently occurs in chronic lung diseases and may cause ventilation inhomogeneity (VI), which can be assessed by washout tests of inert tracer gas. Using two tracer gases with unequal molar mass (MM) and diffusivity increases specificity for VI in different lung zones. Currently washout tests are underutilised due to the time and effort required for measurements. The aim of this study was to develop and validate a simple technique for a new tidal single breath washout test (SBW) of sulfur hexafluoride (SF(6)) and helium (He) using an ultrasonic flowmeter (USFM). The tracer gas mixture contained 5% SF(6) and 26.3% He, had similar total MM as air, and was applied for a single tidal breath in 13 healthy adults. The USFM measured MM, which was then plotted against expired volume. USFM and mass spectrometer signals were compared in six subjects performing three SBW. Repeatability and reproducibility of SBW, i.e., area under the MM curve (AUC), were determined in seven subjects performing three SBW 24 hours apart. USFM reliably measured MM during all SBW tests (n = 60). MM from USFM reflected SF(6) and He washout patterns measured by mass spectrometer. USFM signals were highly associated with mass spectrometer signals, e.g., for MM, linear regression r-squared was 0.98. Intra-subject coefficient of variation of AUC was 6.8%, and coefficient of repeatability was 11.8%. The USFM accurately measured relative changes in SF(6) and He washout. SBW tests were repeatable and reproducible in healthy adults. We have developed a fast, reliable, and straightforward USFM based SBW method, which provides valid information on SF(6) and He washout patterns during tidal breathing.

  16. Tidal volume single breath washout of two tracer gases--a practical and promising lung function test.

    Directory of Open Access Journals (Sweden)

    Florian Singer

    Full Text Available BACKGROUND: Small airway disease frequently occurs in chronic lung diseases and may cause ventilation inhomogeneity (VI, which can be assessed by washout tests of inert tracer gas. Using two tracer gases with unequal molar mass (MM and diffusivity increases specificity for VI in different lung zones. Currently washout tests are underutilised due to the time and effort required for measurements. The aim of this study was to develop and validate a simple technique for a new tidal single breath washout test (SBW of sulfur hexafluoride (SF(6 and helium (He using an ultrasonic flowmeter (USFM. METHODS: The tracer gas mixture contained 5% SF(6 and 26.3% He, had similar total MM as air, and was applied for a single tidal breath in 13 healthy adults. The USFM measured MM, which was then plotted against expired volume. USFM and mass spectrometer signals were compared in six subjects performing three SBW. Repeatability and reproducibility of SBW, i.e., area under the MM curve (AUC, were determined in seven subjects performing three SBW 24 hours apart. RESULTS: USFM reliably measured MM during all SBW tests (n = 60. MM from USFM reflected SF(6 and He washout patterns measured by mass spectrometer. USFM signals were highly associated with mass spectrometer signals, e.g., for MM, linear regression r-squared was 0.98. Intra-subject coefficient of variation of AUC was 6.8%, and coefficient of repeatability was 11.8%. CONCLUSION: The USFM accurately measured relative changes in SF(6 and He washout. SBW tests were repeatable and reproducible in healthy adults. We have developed a fast, reliable, and straightforward USFM based SBW method, which provides valid information on SF(6 and He washout patterns during tidal breathing.

  17. Aspects of Lubrication in a Reciprocating Single-ring Test Rig and Further Implementation to Engine Applications

    Directory of Open Access Journals (Sweden)

    P.S. Dellis

    2017-06-01

    Full Text Available A major concern in modern engine design is the issue of the lubrication regime at the piston-liner assembly. To fully understand the complex lubrication phenomena between the piston-rings and cylinder liner in reciprocating engines and at the same time achieve minimal energy losses with the oncoming emission regulations, it is important to characterize the developing oil film. This dynamic process involves many factors, such as piston-ring and piston dynamics, starved lubrication, liner geometry deformation, lubricant - additive degradation and blow-by, which, in turn, enhance the difficulty of interpreting engine experimental results. The simplified test rig is used as a platform to develop oil film measuring techniques and study experimental results from different sensors by means of a robust and solid technique without the engine testing ambiguities, at different lubrication regimes. This paper is focused on experimental findings from the simplified test rig and how these can be applied on specially modified engines, with the respective sensors fitted. A comparison between the single-ring test rig and the engine visualization results is attempted so that similar forms of cavitation identified, be further studied. Moreover, a calibration coefficient for LIF engine experiments can be derived via the simplified test rig arrangement.

  18. High-Gradient Test of a 3 GHz Single-Cell Cavity

    CERN Document Server

    Verdú-Andrés, S; Bonomi, R; Degiovanni, A; Garlasché, M; Garonna, A; Mellace, C; Pearce, P; S. Verdú-Andrés; Wegner, R

    2010-01-01

    Pro­ton and car­bon ion beams pre­sent ad­van­ta­geous depth-dose dis­tri­bu­tions with re­spect to X-rays. Car­bon ions allow a bet­ter con­trol of "ra­diore­sis­tant" tu­mours due to their high­er bi­o­log­i­cal re­sponse. For deep-seat­ed tu­mours pro­ton and car­bon ion beams of some nA and en­er­gies of about 200 MeV and 400 MeV/u re­spec­tive­ly are need­ed. For these ap­pli­ca­tions TERA pro­posed the "cy­clinac": a high-fre­quen­cy linac which boosts the hadrons ac­cel­er­at­ed by a cy­clotron. The di­men­sions of the com­plex can be re­duced if high­er ac­cel­er­at­ing gra­di­ents are achieved in the linac. To test the max­i­mum achiev­able fields, a 3 GHz cav­i­ty has been built by TERA. The 19 mm-long cell is fore­seen to be ex­cit­ed at 200 Hz by 3 us RF puls­es and should reach a 40 MV/m ac­cel­er­at­ing gra­di­ent, which cor­re­sponds to a peak sur­face elec­tric field Es of 260 MV/m. In a first high-pow­er test per­for...

  19. Depth-discrete specific storage in fractured sedimentary rock using steady-state and transient single-hole hydraulic tests

    Science.gov (United States)

    Quinn, Patryk M.; Cherry, John A.; Parker, Beth L.

    2016-11-01

    A method is presented for obtaining depth-discrete values of specific storage (Ss) from single-hole hydraulic tests in fractured rock boreholes using straddle packers (1.5-17 m test intervals). Low flow constant head (CH) step tests analyzed using the Thiem method provide transmissivity (T) values free from non-Darcian error. Short-term, constant-rate pumping tests (0.5-2 h) analyzed using the Cooper-Jacob approximation of the Theis method provide S from the hydraulic diffusivity using the Darcian T value from the CH step test. This synergistic use of two types of hydraulic tests avoids the common source of error when pumping tests (injection or withdrawal) are conducted at higher flow rates and thereby induce non-Darcian flow resulting in the underestimation of T. Other errors, such as well bore storage and leakage, can also substantially influence S by causing a shift in the time axis of the Cooper-Jacob semi-log plot. In this approach, the Darcian T values from the CH step tests are used in the analysis of the transient pumping test data for calculating S throughout the pumping test using the Cooper-Jacob approximation to minimize all of the aforementioned errors, resulting in more representative S values. The effect of these non-idealities on the measured drawdown is illustrated using the Theis equation with the Darcian T and S values to calculate drawdown for comparison to measured data. The Ss values for tests in sandstone obtained from this approach are more consistent with confined aquifer conditions than values derived from the traditional Cooper-Jacob method, and are within the range of field and lab values presented from a compilation of literature values for fractured sandstone. (10-7-10-5 m-1) This method for obtaining Ss values from short-interval, straddle packer tests improves the estimation of both K and Ss and provides opportunity to study their spatial distribution in fractured rock.

  20. Development of a reference material of a single DNA molecule for the quality control of PCR testing.

    Science.gov (United States)

    Mano, Junichi; Hatano, Shuko; Futo, Satoshi; Yoshii, Junji; Nakae, Hiroki; Naito, Shigehiro; Takabatake, Reona; Kitta, Kazumi

    2014-09-02

    We developed a reference material of a single DNA molecule with a specific nucleotide sequence. The double-strand linear DNA which has PCR target sequences at the both ends was prepared as a reference DNA molecule, and we named the PCR targets on each side as confirmation sequence and standard sequence. The highly diluted solution of the reference molecule was dispensed into 96 wells of a plastic PCR plate to make the average number of molecules in a well below one. Subsequently, the presence or absence of the reference molecule in each well was checked by real-time PCR targeting for the confirmation sequence. After an enzymatic treatment of the reaction mixture in the positive wells for the digestion of PCR products, the resultant solution was used as the reference material of a single DNA molecule with the standard sequence. PCR analyses revealed that the prepared samples included only one reference molecule with high probability. The single-molecule reference material developed in this study will be useful for the absolute evaluation of a detection limit of PCR-based testing methods, the quality control of PCR analyses, performance evaluations of PCR reagents and instruments, and the preparation of an accurate calibration curve for real-time PCR quantitation.

  1. Single molecule measurements of DNA helicase activity with magnetic tweezers and t-test based step-finding analysis

    Science.gov (United States)

    Seol, Yeonee; Strub, Marie-Paule; Neuman, Keir C.

    2016-01-01

    Magnetic tweezers is a versatile and easy to implement single-molecule technique that has become increasingly prevalent in the study of nucleic acid based molecular motors. Here, we provide a description of the magnetic tweezers instrument and guidelines for measuring and analyzing DNA helicase activity. Along with experimental methods, we describe a robust method of single-molecule trajectory analysis based on the Student’s t-test that accommodates continuous transitions in addition to the discrete transitions assumed in most widely employed analysis routines. To illustrate the single-molecule unwinding assay and the analysis routine, we provide DNA unwinding measurements of Escherichia coli RecQ helicase under a variety of conditions (Na+, ATP, temperature, and DNA substrate geometry). These examples reveal that DNA unwinding measurements under various conditions can aid in elucidating the unwinding mechanism of DNA helicase but also emphasize that environmental effects on DNA helicase activity must be considered in relation to in vivo activity and mechanism. PMID:27131595

  2. Image reconstruction in single photon emission computed tomography for radioactive waste testing

    International Nuclear Information System (INIS)

    Pouletaut, P.

    1993-02-01

    The aim of this study is to reconstruct by tomography the spatial distribution of the activity of an object which emits photons. First, an analysis of the imaging qualities of a tomograph in terms of physical parameters related to the measurement process is proposed. Then, an algorithm which evaluates, the self-attenuation of the emitted photons and corrects for the collimator aperture angle is developed; this computation corresponds to a subdivision of the object into voxels and to a parallel geometry of the projections. Two algebraic reconstruction methods have been studied; one using a regularized least-squares technique, the other using a bayesian approach. We show by computer simulations the dependence of the reconstruction on the condition number of the self-attenuation matrix and on the estimation errors of this matrix. Then, the reconstruction is tested on experimental data; the images we reconstruct on a square grid of ten by ten voxels from one hundred twenty measurements show an accurate location of the sources; their activities are efficiently estimated when the collimator aperture angle is well taken into account in the self-attenuation matrix

  3. Test of single degree of freedom acoustic treatment impedance models for multimodal acoustic propagation in duct with flow.

    Science.gov (United States)

    Baccouche, Ryan; Moreau, Soléne; Ben Tahar, Mabrouk

    2017-06-01

    Passive acoustic treatments, also called liners, are the main solution to noise problems. The Single Degree Of Freedom (SDOF) acoustic treatment, composed of a thin material (perforated plate) affixed to air cavities with a rigid bottom, constitutes a solution. Predicting sound level reduction by an SDOF treatment requires reliable acoustic impedance models. An experimental/numerical method has been developed for a duct with an acoustic treatment to test acoustic impedance models of SDOF treatment with a multimodal propagation in the presence of a mean flow. This method is based on the comparison of experimental results from an aeroacoustic bench composed of a circular duct with a treated area, and numerical results from an FEM-PML axisymmetric model based on Galbrun's equation. The numerical results are confronted with experimental results to test impedance models up to M 0 =±0.25.

  4. Testing a Poisson counter model for visual identification of briefly presented, mutually confusable single stimuli in pure accuracy tasks.

    Science.gov (United States)

    Kyllingsbæk, Søren; Markussen, Bo; Bundesen, Claus

    2012-06-01

    The authors propose and test a simple model of the time course of visual identification of briefly presented, mutually confusable single stimuli in pure accuracy tasks. The model implies that during stimulus analysis, tentative categorizations that stimulus i belongs to category j are made at a constant Poisson rate, v(i, j). The analysis is continued until the stimulus disappears, and the overt response is based on the categorization made the greatest number of times. The model was evaluated by Monte Carlo tests of goodness of fit against observed probability distributions of responses in two extensive experiments and also by quantifications of the information loss of the model compared with the observed data by use of information theoretic measures. The model provided a close fit to individual data on identification of digits and an apparently perfect fit to data on identification of Landolt rings.

  5. A gold nanoparticles-based colorimetric test to detect single nucleotide polymorphisms for improvement of personalized therapy of psoriasis

    Science.gov (United States)

    Marsella, Alessandra; Valentini, Paola; Tarantino, Paolo; Congedo, Maurizio; Pompa, Pier Paolo

    2016-04-01

    We report a simple, rapid and low-cost test, based on gold nanoparticles, for the naked-eye colorimetric detection of a signature of single nucleotide polymorphisms (SNPs) relevant for the personalized medicine of psoriasis patients. We validated the colorimetric assay on real-world DNA samples from a cohort of 30 psoriasis patients and we compared the results, in double-blind, with those obtained with two state-of-the-art instrumental techniques, namely reverse dot blotting and direct sequencing, finding 100% agreement. We demonstrated high accuracy, sensitivity and specificity of the colorimetric test that can be easily adapted for the genotypization of different SNPs, important for the pharmacogenomics of various diseases, and in other fields, such as food traceability and population structure analysis.

  6. Flexible session management in a distributed environment

    Energy Technology Data Exchange (ETDEWEB)

    Miller, Zach; /Wisconsin U., Madison; Bradley, Dan; /Wisconsin U., Madison; Tannenbaum, Todd; /Wisconsin U., Madison; Sfiligoi, Igor; /Fermilab

    2010-01-01

    Many secure communication libraries used by distributed systems, such as SSL, TLS, and Kerberos, fail to make a clear distinction between the authentication, session, and communication layers. In this paper we introduce CEDAR, the secure communication library used by the Condor High Throughput Computing software, and present the advantages to a distributed computing system resulting from CEDAR's separation of these layers. Regardless of the authentication method used, CEDAR establishes a secure session key, which has the flexibility to be used for multiple capabilities. We demonstrate how a layered approach to security sessions can avoid round-trips and latency inherent in network authentication. The creation of a distinct session management layer allows for optimizations to improve scalability by way of delegating sessions to other components in the system. This session delegation creates a chain of trust that reduces the overhead of establishing secure connections and enables centralized enforcement of system-wide security policies. Additionally, secure channels based upon UDP datagrams are often overlooked by existing libraries; we show how CEDAR's structure accommodates this as well. As an example of the utility of this work, we show how the use of delegated security sessions and other techniques inherent in CEDAR's architecture enables US CMS to meet their scalability requirements in deploying Condor over large-scale, wide-area grid systems.

  7. A Pilot Study on Single-dose Toxicity Testing of Hominis placenta Pharmacopuncture in Sprague-Dawley Rats

    Directory of Open Access Journals (Sweden)

    Yoo-Hwan Lee

    2015-06-01

    Full Text Available Objectives: This study was performed to analyze the toxicity and to find the lethal dose of the test substance Hominis placenta pharmacopuncture when used as a single-dose in 6 week old, male and female Sprague-Dawley (SD rats. Methods: All experiments were conducted at Biotoxtech (Chungwon, Korea, an institution authorized to perform non clinical studies, under the regulations of Good Laboratory Practice (GLP. SD rats were chosen for the pilot study. Doses of Hominis placenta pharmacopuncture extracts, 0.125, 0.25 and 0.5 mL, were administered to the experimental group, and 0.5 mL doses of normal saline solution were administered to the control group. This study was conducted under the approval of the Institutional Animal Ethics Committee. Results: No deaths or abnormalities occurred in any of the groups. Also, no significant changes in body weights were observed among the groups, and no significant differences in hematology/biochemistry, necropsy, and histopathology results were noted. Hematologically, some changes in the male rats in two experimental groups were observed, but those changes had no clinical or toxicological meaning because they were not dose dependent. Histopathological tests on the injected parts showed cell infiltration in the male rats in one of the experimental groups; however, that result was due to spontaneous generation and had no toxicological meaning. Therefore, this study showed that Hominis placenta pharmacopuncture had no effect on the injected parts in terms of clinical signs, body weight, hematology, clinical chemistry, and necropsy. Conclusion: As a result of single-dose tests of the test substance Hominis placenta pharmacopuncture in 4 groups of rats, the lethal dose for both males and females exceeded 0.5 mL/animal. Therefore, the above findings suggest that treatment with Hominis placenta pharmacopuncture is relatively safe. Further studies on this subject are needed.

  8. Third session: new projects; Session 3: Les Projets nouveaux

    Energy Technology Data Exchange (ETDEWEB)

    Iracane, D. [CEA Saclay, Dir. de l' Energie Nucleaire (DEN), 91 - Gif sur Yvette (France); Dupuy, J.P. [AREVA-Technicatome, 13 - Aix en Provence (France); Perotto, G. [AREVA-Framatome-ANP, 13 - Aix en Provence (France); Ithurralde, G. [Electricite de France (EDF), 13 - Aix en Provence (France); Cabrillat, J.C. [CEA Cadarache, Dir. de l' Energie Nucleaire (DEN), 13 - Saint-Paul-lez-Durance (France); Becle, D. [FRAMATOME, AREVA-FANP, 69 - Lyon (France); Pivet, S. [CEA Bruyeres-le-Chatel, 91 (France); Minguet, J.L. [AREVA-Technicatome, 75 - Paris (France)

    2005-07-01

    The RJH (Jules Horowitz reactor) is a 100 MWth research reactor, cooled and moderated by water, that has been designed to operate with high density (8 g U/cm{sup 3}) and low enrichment fuel (19.75%) uranium molybdenum fuel. Its main neutron performances are expected to be: -) maximum fast neutron flux (E > 0.907 MeV) in the sample: 5.10{sup 14} n/cm{sup 2}/s, -) maximum thermal neutron flux (E < 0.625 eV): 4.10{sup 14} n/cm{sup 2}/s, and -) maximal neutron damage: 16 dpa/year. RJH that will be built on the Cea's site of Cadarache, is scheduled to enter into service in 2014, it will take over the activities of the Osiris reactor and its operating life is planned to be over 50 years long. The Cabri research reactor is located on the Cadarache site, it has been operating since 1962 and is now undergoing important upgrading operations whose aim is to make the facility fit to study the behaviour of new nuclear fuels in accidental situations. The RES test reactor is a facility whose aim is to qualify nuclear fuels and core configurations of existing propulsion reactors onboard of aircraft carriers or submarines and to propose innovative concepts for future propulsion reactors. (A.C.)

  9. Testing the single-pass VOC removal efficiency of an active green wall using methyl ethyl ketone (MEK).

    Science.gov (United States)

    Torpy, Fraser; Clements, Nicholas; Pollinger, Max; Dengel, Andy; Mulvihill, Isaac; He, Chuan; Irga, Peter

    2018-01-01

    In recent years, research into the efficacy of indoor air biofiltration mechanisms, notably living green walls, has become more prevalent. Whilst green walls are often utilised within the built environment for their biophilic effects, there is little evidence demonstrating the efficacy of active green wall biofiltration for the removal of volatile organic compounds (VOCs) at concentrations found within an interior environment. The current work describes a novel approach to quantifying the VOC removal effectiveness by an active living green wall, which uses a mechanical system to force air through the substrate and plant foliage. After developing a single-pass efficiency protocol to understand the immediate effects of the system, the active green wall was installed into a 30-m 3 chamber representative of a single room and presented with the contaminant 2-butanone (methyl ethyl ketone; MEK), a VOC commonly found in interior environments through its use in textile and plastic manufacture. Chamber inlet levels of MEK remained steady at 33.91 ± 0.541 ppbv. Utilising a forced-air system to draw the contaminated air through a green wall based on a soil-less growing medium containing activated carbon, the combined effects of substrate media and botanical component within the biofiltration system showed statistically significant VOC reduction, averaging 57% single-pass removal efficiency over multiple test procedures. These results indicate a high level of VOC removal efficiency for the active green wall biofilter tested and provide evidence that active biofiltration may aid in reducing exposure to VOCs in the indoor environment.

  10. Design and evaluation of interprofessional cross-cultural communication sessions.

    Science.gov (United States)

    Liu, Min; Poirier, Therese; Butler, Lakesha; Comrie, Rhonda; Pailden, Junvie

    2015-01-01

    The 2013 National Standards for Culturally and Linguistically Appropriate Services (CLAS) call for healthcare professionals to provide quality care and services that are responsive to diverse cultural health beliefs and practices. Accreditation organizations for health professional programs require their curriculum to adequately prepare future practitioners for serving culturally and linguistically diverse populations. Another common curricular need of health professional programs is interprofessional education (IPE). This study presents data that evaluates two IPE culturally competent communication sessions designed for pharmacy and nursing students. Teams of nursing and pharmacy students (n = 160) engaged in case studies focused on developing cross-cultural communication skills, using the LEARN model. Quantitative survey data collected pre-test and post-test measured cultural competency (including subscales of perceived skills, perceived knowledge, confidence in encounter, and attitude) and knowledge related to culturally competent communication. Univariate ANOVA results indicate that actual knowledge as measured by the test and all four Clinical Cultural Competency Questionnaire (CCCQ) subscales significantly increased after the IPE sessions. Pharmacy students scored higher than nursing students on the knowledge pre-test, and nursing students had a more positive attitude at pre-test. The IPE sessions effectively addressed all learning outcomes and will continue in future course offerings. Using cross-cultural communication as a thematic area for IPE program development resulted in educational benefits for the students. To further strengthen nursing and pharmacy students' interprofessional practice, additional IPE opportunities are to be explored.

  11. pH(stat) vs. single extraction tests to evaluate heavy metals and arsenic leachability in environmental samples.

    Science.gov (United States)

    Rigol, A; Mateu, J; González-Núñez, R; Rauret, G; Vidal, M

    2009-01-19

    Here we compared the pH(stat) test, which examines the leachability of major elements (Ca, Mg, Al, Fe, and Mn), dissolved organic carbon, and trace elements (Cd, Zn, Cu, Pb, and As) in a wide pH range, with single extraction tests based on the use of mild extractants (calcium chloride, acetic acid or EDTA). For this purpose, we examined samples from a variety of environmental conditions (sludges, mineral soils, organic soils, and soils with particulate and/or soluble contamination). Extraction yields obtained with CaCl(2) (0.01 mol L(-1)) and CH(3)COOH (0.43 mol L(-1)) correlated well with those from the pH(stat) at the same pH (r=0.98 and 0.95, respectively), while the use of EDTA (0.05 mol L(-1)) led to systematically higher extraction yields than those quantified with the pH(stat) at the same pH. However, the pH(stat) test had three distinct advantages: (1) it revealed the relationship between the solubility of the main soil phases and pH; (2) it showed the variation in pollutant leachability due to changes in pH; and (3) it better predicted the maximum contaminant availability. Thus we propose that the pH(stat) is the best laboratory tests to evaluate the contaminant leachability over a wide range of sample types (soil, sludge, and sediment).

  12. Alternatives to Animal Use in Research and Testing. Hearing before the Subcommittee on Science, Research and Technology of the Committee on Science and Technology. House of Representatives, Ninety-Ninth Congress, Second Session.

    Science.gov (United States)

    Congress of the U.S., Washington, DC. House Committee on Science and Technology.

    Perspectives, policy issues, and options for Congressional action that relate most directly to the development and implementation of alternatives to animal use in research and testing are addressed in this report. Testimonies and reports include those from the Office of Technology Assessment, the National Institute of Health, and the Food and Drug…

  13. Drug Testing in Schools: An Effective Deterrent? Hearing before the Subcommittee on Criminal Justice, Drug Policy, and Human Resources of the Committee on Government Reform. House of Representatives, One Hundred Sixth Congress, Second Session (May 30, 2000).

    Science.gov (United States)

    Congress of the U.S., Washington, DC. House Committee on Government Reform.

    This document presents testimonies from a hearing discussing the drug threat in the nations schools and the issue of whether drug testing is an effective deterrent. The subcommittee conducted the hearing as part of an effort to fully understand the nations drug crisis, how it impacts different parts of our nation, and what effective drug control…

  14. Performance evaluation testing of wells in the gradient control system at a federally operated Confined Disposal Facility using single well aquifer tests, East Chicago, Indiana

    Science.gov (United States)

    Lampe, David C.; Unthank, Michael D.

    2016-12-08

    values from the initial air slug test during the 2015 testing period for MW–11A and MW–14A are an order of magnitude less than those derived from the final test during the 2014 testing period indicating the development of a low conductivity skin between the final test of the 2014 testing period and the beginning of the 2015 testing period that created a decrease in the connection of the monitoring well screen to the surrounding aquifer material.Repeated step drawdown and recovery testing of the extraction wells tested during this study provided results that indicate a slight increase in the development of a skin and a decrease in the connectivity of the extraction wells with the Calumet aquifer. Hydraulic conductivity values obtained from the test results were relatively similar in EW–4B and EW–14A but were substantially lower for EW–11C. This difference may be due to the presence of finer grained silt deposits in the area surrounding well nest 11. Skin factors calculated during the step drawdown and recovery analysis were lowest in EW–11C and relatively similar in EW–4B and EW–14A. Calculated skin factors increased slightly in the analysis of data collected in 2015 from that collected in 2014.Comparisons of the specific-capacity values calculated from well development data collected following extraction well installation to those calculated during the single well aquifer tests at EW–4B, EW–14A and EW–11C indicate that the productivity of extraction wells on the CDF property has diminished since 2008. Values calculated for monitoring wells MW–4A, MW–11A, and MW–14A were used to evaluate the decrease in air slug derived hydraulic conductivity for monitoring wells within the groundwater cutoff wall between testing in 2014 and 2015.Results from testing by this study indicate that implementation of an air slug testing regimen of the monitoring wells that control the gradient control system at the CDF throughout the course of a year may help

  15. Effects of sediment-spiked lufenuron on benthic macroinvertebrates in outdoor microcosms and single-species toxicity tests.

    Science.gov (United States)

    Brock, T C M; Bas, D A; Belgers, J D M; Bibbe, L; Boerwinkel, M-C; Crum, S J H; Diepens, N J; Kraak, M H S; Vonk, J A; Roessink, I

    2016-08-01

    Sediment ecotoxicity studies were conducted with lufenuron to (i) complement the results of a water-spiked mesocosm experiment with this lipophilic benzoylurea insecticide, (ii) to explore the predictive value of laboratory single-species tests for population and community-level responses of benthic macroinvertebrates, and (iii) to calibrate the tier-1 effect assessment procedure for sediment organisms. For this purpose the concentration-response relationships for macroinvertebrates between sediment-spiked microcosms and those of 28-d sediment-spiked single-species toxicity tests with Chironomus riparius, Hyalella azteca and Lumbriculus variegatus were compared. Lufenuron persisted in the sediment of the microcosms. On average, 87.7% of the initial lufenuron concentration could still be detected in the sediment after 12 weeks. Overall, benthic insects and crustaceans showed treatment-related declines and oligochaetes treatment-related increases. The lowest population-level NOEC in the microcosms was 0.79μg lufenuron/g organic carbon in dry sediment (μg a.s./g OC) for Tanytarsini, Chironomini and Dero sp. Multivariate analysis of the responses of benthic macroinvertebrates revealed a community-level NOEC of 0.79μg a.s./g OC. The treatment-related responses observed in the microcosms are in accordance with the results of the 28-d laboratory toxicity tests. These tests showed that the insect C. riparius and the crustacean H. azteca were approximately two orders of magnitude more sensitive than the oligochaete L. variegatus. In our laboratory tests, using field-collected sediment, the lowest 28-d EC10 (0.49μg a.s./g OC) was observed for C. riparius (endpoint survival), while for the standard OECD test with this species, using artificial sediment, a NOEC of 2.35μg a.s./g OC (endpoint emergence) is reported. In this particular case, the sediment tier-1 effect assessment using the chronic EC10 (field-collected sediment) or chronic NOEC (artificial sediment) of C

  16. Effects of sediment-spiked lufenuron on benthic macroinvertebrates in outdoor microcosms and single-species toxicity tests

    Energy Technology Data Exchange (ETDEWEB)

    Brock, T.C.M., E-mail: theo.brock@wur.nl [Alterra, Wageningen University and Research Centre, P.O. Box 47, 6700 AA Wageningen (Netherlands); Bas, D.A. [Institute for Biodiversity and Ecosystem Dynamics (IBED), University of Amsterdam (Netherlands); Belgers, J.D.M. [Alterra, Wageningen University and Research Centre, P.O. Box 47, 6700 AA Wageningen (Netherlands); Bibbe, L. [Institute for Biodiversity and Ecosystem Dynamics (IBED), University of Amsterdam (Netherlands); Boerwinkel, M-C.; Crum, S.J.H. [Alterra, Wageningen University and Research Centre, P.O. Box 47, 6700 AA Wageningen (Netherlands); Diepens, N.J. [Department of Aquatic Ecology and Water Quality Management, Wageningen University, P.O. Box 47, 6700 AA Wageningen (Netherlands); Kraak, M.H.S.; Vonk, J.A. [Institute for Biodiversity and Ecosystem Dynamics (IBED), University of Amsterdam (Netherlands); Roessink, I. [Alterra, Wageningen University and Research Centre, P.O. Box 47, 6700 AA Wageningen (Netherlands)

    2016-08-15

    Highlights: • In outdoor microcosms constructed with lufenuron-spiked sediment we observed that this insecticide persistent in the sediment compartment. • Sediment exposure to lufenuron caused population-level declines (insects and crustaceans) and increases (mainly oligochaete worms) of benthic invertebrates. • The direct and indirect effects observed in the microcosms were supported by results of sediment-spiked single species tests with Chironomus riparius, Hyalella azteca and Lumbriculus variegatus. • The tier-1 effect assessment procedure for sediment organisms recommended by the European Food Safety Authority is protective for the treatment-related responses observed in the microcosm test. - Abstract: Sediment ecotoxicity studies were conducted with lufenuron to (i) complement the results of a water-spiked mesocosm experiment with this lipophilic benzoylurea insecticide, (ii) to explore the predictive value of laboratory single-species tests for population and community-level responses of benthic macroinvertebrates, and (iii) to calibrate the tier-1 effect assessment procedure for sediment organisms. For this purpose the concentration-response relationships for macroinvertebrates between sediment-spiked microcosms and those of 28-d sediment-spiked single-species toxicity tests with Chironomus riparius, Hyalella azteca and Lumbriculus variegatus were compared. Lufenuron persisted in the sediment of the microcosms. On average, 87.7% of the initial lufenuron concentration could still be detected in the sediment after 12 weeks. Overall, benthic insects and crustaceans showed treatment-related declines and oligochaetes treatment-related increases. The lowest population-level NOEC in the microcosms was 0.79 μg lufenuron/g organic carbon in dry sediment (μg a.s./g OC) for Tanytarsini, Chironomini and Dero sp. Multivariate analysis of the responses of benthic macroinvertebrates revealed a community-level NOEC of 0.79 μg a.s./g OC. The treatment

  17. The comparative performance of the single intradermal comparative tuberculin test in Irish cattle, using tuberculin PPD combinations from different manufacturers.

    Science.gov (United States)

    Good, M; Clegg, T A; Murphy, F; More, S J

    2011-07-05

    Ireland currently obtains its avian and bovine tuberculin purified protein derivatives (PPDs) from a single source. Because problems of supply or quality cannot be discounted, it is prudent that Ireland identify alternative supplier(s) as part of a broad risk management strategy. Therefore, the aim of this study was to compare the performance of a number of different tuberculin combinations (that is, pairings of bovine and avian PPD; with different manufacturers) in the single intradermal comparative tuberculin test (SICTT), as currently performed in Ireland. The study was randomised, controlled and double-blinded. A total of 2172 cattle were used in the study. Each animal was tested using two SICTTs, the first based on the tuberculin combination in current use, and the second using one of six trial tuberculin combinations. Analyses were conducted to compare both reactor-status and skin increase. For each control/trial tuberculin combination, there was good agreement between the control and trial reactor-status. Differences in skin increases were mainly confined to animals categorised as either negative or severe inconclusive. However, the measured differences were minor, and unlikely to have a significant impact on the actual test outcome, either for individual animals or for herds. In conclusion, while further studies determining sensitivity and specificity in Ireland would have to be done in the event of a change in tuberculin PPD there should be minimal disruption of the national programme if alternative tuberculin PPDs meeting WHO, OIE and EU regulations were used. In this study, the precision of the guinea pig bio-assay to assess tuberculin potency was low and therefore Ireland should maintain its practice of periodically assessing potency in naturally infected cattle, even though this is not currently required under WHO, OIE or EU Regulations. Copyright © 2011 Elsevier B.V. All rights reserved.

  18. Work session on the SAR. Pt. 2

    International Nuclear Information System (INIS)

    Burkart, K.

    1980-01-01

    The present paper contains the tables of the contribution of K. Burkart 'Work Session on the SAR' to the IAEA Interregional Training Course held in Sept/Oct. 1980 at the Kernforschungszentrum Karlsruhe. (RW)

  19. Session summary: Electronics, triggering and data acquisition

    International Nuclear Information System (INIS)

    Rescia, S.

    1991-12-01

    The session focused on the requirements for calorimetry at the SSC/LHC. Results on new readout techniques, calibration, radiation hard electronics and semiconductor devices, analog and digital front and electronics, and trigger strategies are presented

  20. Summary of the relativistic heavy ion sessions

    International Nuclear Information System (INIS)

    Harris, J.W.

    1988-01-01

    The topics covered in the Relativistic Heavy Ion Sessions span four orders of magnitude in energy in the laboratory and a few more in theory. In the two years since the last Intersections conference, experiments in the field of very high energy heavy ion research have begun at CERN and Brookhaven. The prime motivation for these experiments is the possibility of forming quark matter. This paper is a review of the topics covered in the Relativistic Heavy Ion Sessions

  1. SUCCESS RATE OF ONE SESSION AND TWO SESSION TECHNIQUES FOR TREATMENT OF ASYMPTOMATIC PULPITIS OF PRIMARY TEETH WITH INDIRECT PULP CAPPING.

    Directory of Open Access Journals (Sweden)

    Rossitza Kabaktchieva

    2013-01-01

    Full Text Available Objective: Objective: To compare the success rate between the one session and two session indirect pulp capping of asymptomatic pulpitis for 1 year after the treatment was performed in children with different caries risk. Material and Methods: The children and the teeth were selected according to certain criteria for inclusion in the study. According to that, 72 children with low, moderate and high caries risk were included and 131 teeth with asymptomatic pulpitis were treated. The clinical protocols for indirect pulp capping (IPC in one session and two sessions were defined. The review appointments were performed 6 and 12 months after the treatment using certain clinical and radiographic criteria which defined success or post-treatment complications. The results are statistically analysed using One Sided Exact Two-Proportion Test with 95% Significance level (5% risk of type I error. Results: The statistical test showed that between the compared success rates of the one session and two sessions IPC, on the 6th and 12th month, there wasn’t a significant difference (p>0.05. This was valid for every one of the examined groups of patients (p>0. 05. This proves that there is no difference in the success rates of treatment of pulpitis in primary teeth using one or two sessions. Conclusions: The results about the success of treatment of asymptomatic pulpitis in primary teeth during one or two sessions have confirmed the results showed in other current studies. Our study has confirmed (clinically and radiographically the success of both techniques and we have concluded that in children with high caries risk, more appropriate technique is the one performed in two sessions. Treatment in one session is recommended in children with low or moderate caries risk.

  2. Development of Guidelines for Use of Proton Single-Event Test Data to Bound Single-Event Effect Susceptibility Due to Light Ions

    Data.gov (United States)

    National Aeronautics and Space Administration — Conventional methods for Single-Event Effects (SEE) Hardness Assurance have proven difficult to adapt to Explorer, Cubesat and other risk tolerant platforms with...

  3. Acquisition of Skill Proficiency Over Multiple Sessions of a Novel Rover Simulation

    Science.gov (United States)

    Dean, S. L.; DeDios,Y. E.; MacDougall, H. G.; Moore, S. T.; Wood, S. J.

    2011-01-01

    Following long-duration exploration transits, adaptive changes in sensorimotor function may impair the crew's ability to safely perform manual control tasks such as operating pressurized rovers. Postflight performance will also be influenced by the level of preflight skill proficiency they have attained. The purpose of this study was to characterize the acquisition of skills in a motion-based rover simulation over multiple sessions, and to investigate the effects of varying the simulation scenarios. METHODS: Twenty healthy subjects were tested in 5 sessions, with 1-3 days between sessions. Each session consisted of a serial presentation of 8 discrete tasks to be completed as quickly and accurately as possible. Each task consisted of 1) perspective-taking, using a map that defined a docking target, 2) navigation toward the target around a Martian outpost, and 3) docking a side hatch of the rover to a visually guided target. The simulator utilized a Stewart-type motion base (CKAS, Australia), single-seat cabin with triple scene projection covering 150 deg horizontal by 50 deg vertical, and joystick controller. Subjects were randomly assigned to a control group (tasks identical in the first 4 sessions) or a varied-practice group. The dependent variables for each task included accuracy toward the target and time to completion. RESULTS: The greatest improvements in time to completion occurred during the docking phase. The varied-practice group showed more improvement in perspective-taking accuracy. Perspective-taking accuracy was also affected by the relative orientation of the rover to the docking target. Skill acquisition was correlated with self-ratings of previous gaming experience. DISCUSSION: Varying task selection and difficulty will optimize the preflight acquisition of skills when performing novel operational tasks. Simulation of operational manual control will provide functionally relevant evidence regarding the impact of sensorimotor adaptation on early

  4. Testing single and double limb standing balance performance: comparison of COP path length evaluation between two devices.

    Science.gov (United States)

    Donath, Lars; Roth, Ralf; Zahner, Lukas; Faude, Oliver

    2012-07-01

    Center of pressure (COP) path length evaluation was commonly applied to measure postural sway and usually obtained from gold standard force plates. Thus, we comparatively investigated the feasible and less-expensive GKS® balance system (GKS) with the Kistler® force platform (KIS). 34 non-specifically trained but active adults (14 males, 20 females, age: 25.4±4.8 years; weight: 69.3±12.3 kg; height: 1.75±0.09 m, sports activity: 5.8±3.6 hours per week) were randomly tested on both devices during double and single limb stance with opened and closed eyes. Irrespective of the analysed time frame, repeated measures analyses of variances revealed higher path length readings for GKS compared to KIS for 30 s (F=6.8, p=0.01) and 10 s (F=21.2, p=0.001). Large effect sizes of the COP path length differences between GKS and KIS decreased from easy tasks (double limb, eyes open; d(30-s)=2.55, d(10-s)=2.04) to the most severe task (single limb, eyes closed; d(30-s)=0.02, d(10-s)=0.23). According to Bland and Altman, the limits of agreements indicated a high random variability component (between 29%, double limb, eyes open and 67%, single limb, eyes closed). The overall intraclass correlation coefficients (ICC) across all four standing balance tasks were moderate for the 30 s- (0.57) as well as the 10 s-analysis (0.65). In conclusion, the COP path length displacements obtained from the GKS balance system seem to differ with a considerable random variability from Kistler force platform data. Thus, measurements of the evaluated devices should not be used interchangeably. Further methodological investigations regarding balance measures seem warranted. Copyright © 2012 Elsevier B.V. All rights reserved.

  5. Workplace testing of the new single sphere neutron spectrometer based on Dysprosium activation foils (Dy-SSS)

    Energy Technology Data Exchange (ETDEWEB)

    Bedogni, R., E-mail: roberto.bedogni@lnf.infn.it [INFN-LNF (Frascati National Laboratories), Via E. Fermi n. 40-00044 Frascati (Italy); Gomez-Ros, J.M. [INFN-LNF (Frascati National Laboratories), Via E. Fermi n. 40-00044 Frascati (Italy); CIEMAT, Av. Complutense 40, 28040 Madrid (Spain); Esposito, A.; Gentile, A.; Chiti, M.; Palacios-Perez, L. [INFN-LNF (Frascati National Laboratories), Via E. Fermi n. 40-00044 Frascati (Italy); Angelone, M. [ENEA C.R. Frascati, C.P. 65, 00044 Frascati (Italy); Tana, L. [A.O. Universitaria Pisana-Ospedale S. Chiara, Via Bonanno Pisano, Pisa (Italy)

    2012-08-21

    A photon insensitive passive neutron spectrometer consisting of a single moderating polyethylene sphere with Dysprosium activation foils arranged along three perpendicular axes was designed by CIEMAT and INFN. The device is called Dy-SSS (Dy foil-based Single Sphere Spectrometer). It shows nearly isotropic response in terms of neutron fluence up to 20 MeV. The first prototype, previously calibrated with 14 MeV neutrons, has been recently tested in workplaces having different energy and directional distributions. These are a 2.5 MeV nearly mono-chromatic and mono-directional beam available at the ENEA Frascati Neutron Generator (FNG) and the photo-neutron field produced in a 15 MV Varian CLINAC DHX medical accelerator, located in the Ospedale S. Chiara (Pisa). Both neutron spectra are known through measurements with a Bonner Sphere Spectrometer. In both cases the experimental response of the Dy-SSS agrees with the reference data. Moreover, it is demonstrated that the spectrometric capability of the new device are independent from the directional distribution of the neutron field. This opens the way to a new generation of moderation-based neutron instruments, presenting all advantages of the Bonner sphere spectrometer without the disadvantage of the repeated exposures. This concept is being developed within the NESCOFI@BTF project of INFN (Commissione Scientifica Nazionale 5).

  6. Design and first tests of miniature K010X soft x-ray streak and single-frame camera

    Science.gov (United States)

    Lebedev, V. B.; Feldman, G. G.; Myasnikov, A. F.; Chernyshev, N. V.; Shubski, I. I.; Liu, Jingru; Wang, Lijun; Zhang, Yongsheng; Zhao, Xueqin; Zheng, Guoxin; Xiao, Weiwei

    2007-01-01

    Description of a new K010X soft X-ray camera and the first results of it tests carried out in Russia and China are presented. In a streak mode the full sweep time for a 2 cm sweep route length on the image converter screen is from 2 ns up to 600 microseconds. In a single-frame mode the corresponding frame duration is from ~10 ns up to ~ 660 microseconds. Spatial resolution in a single frame mode was not less than 5 l.p./mm for soft X-ray radiation and not less 10 l.p./mm for UV radiation. Spatial resolution in a streak mode for soft X-ray radiation was from 5 up to 10 l.p./mm and for UV radiation on all the sweep ranges was not less than 10 l.p./mm, except for the range of 1 ns/cm where it was 5 l.p./mm. Limiting temporal resolution for UV radiation was near 10 ps and a dynamic range was 200 when full sweep time was 60 ns. The camera has small 430×115×200 mm dimensions, 5.0 kg weight and 10 VA power consumption.

  7. Workplace testing of the new single sphere neutron spectrometer based on Dysprosium activation foils (Dy-SSS)

    International Nuclear Information System (INIS)

    Bedogni, R.; Gómez-Ros, J.M.; Esposito, A.; Gentile, A.; Chiti, M.; Palacios-Pérez, L.; Angelone, M.; Tana, L.

    2012-01-01

    A photon insensitive passive neutron spectrometer consisting of a single moderating polyethylene sphere with Dysprosium activation foils arranged along three perpendicular axes was designed by CIEMAT and INFN. The device is called Dy-SSS (Dy foil-based Single Sphere Spectrometer). It shows nearly isotropic response in terms of neutron fluence up to 20 MeV. The first prototype, previously calibrated with 14 MeV neutrons, has been recently tested in workplaces having different energy and directional distributions. These are a 2.5 MeV nearly mono-chromatic and mono-directional beam available at the ENEA Frascati Neutron Generator (FNG) and the photo-neutron field produced in a 15 MV Varian CLINAC DHX medical accelerator, located in the Ospedale S. Chiara (Pisa). Both neutron spectra are known through measurements with a Bonner Sphere Spectrometer. In both cases the experimental response of the Dy-SSS agrees with the reference data. Moreover, it is demonstrated that the spectrometric capability of the new device are independent from the directional distribution of the neutron field. This opens the way to a new generation of moderation-based neutron instruments, presenting all advantages of the Bonner sphere spectrometer without the disadvantage of the repeated exposures. This concept is being developed within the NESCOFI@BTF project of INFN (Commissione Scientifica Nazionale 5).

  8. Workplace testing of the new single sphere neutron spectrometer based on Dysprosium activation foils (Dy-SSS)

    Science.gov (United States)

    Bedogni, R.; Gómez-Ros, J. M.; Esposito, A.; Gentile, A.; Chiti, M.; Palacios-Pérez, L.; Angelone, M.; Tana, L.

    2012-08-01

    A photon insensitive passive neutron spectrometer consisting of a single moderating polyethylene sphere with Dysprosium activation foils arranged along three perpendicular axes was designed by CIEMAT and INFN. The device is called Dy-SSS (Dy foil-based Single Sphere Spectrometer). It shows nearly isotropic response in terms of neutron fluence up to 20 MeV. The first prototype, previously calibrated with 14 MeV neutrons, has been recently tested in workplaces having different energy and directional distributions. These are a 2.5 MeV nearly mono-chromatic and mono-directional beam available at the ENEA Frascati Neutron Generator (FNG) and the photo-neutron field produced in a 15 MV Varian CLINAC DHX medical accelerator, located in the Ospedale S. Chiara (Pisa). Both neutron spectra are known through measurements with a Bonner Sphere Spectrometer. In both cases the experimental response of the Dy-SSS agrees with the reference data. Moreover, it is demonstrated that the spectrometric capability of the new device are independent from the directional distribution of the neutron field. This opens the way to a new generation of moderation-based neutron instruments, presenting all advantages of the Bonner sphere spectrometer without the disadvantage of the repeated exposures. This concept is being developed within the NESCOFI@BTF project of INFN (Commissione Scientifica Nazionale 5).

  9. In situ bend testing of niobium-reinforced alumina nanocomposites with and without single-walled carbon nanotubes

    International Nuclear Information System (INIS)

    Thomson, Katherine E.; Jiang Dongtao; Lemberg, Joseph A.; Koester, Kurt J.; Ritchie, Robert O.; Mukherjee, Amiya K.

    2008-01-01

    Alumina-based nanocomposites were fabricated and consolidated via spark plasma sintering. The effect of single-walled carbon nanotube (SWCNT) and niobium additions to nanocrystalline alumina was examined by in situ bend testing. The addition of 10 vol.% niobium to nanocrystalline alumina provided substantial improvement of fracture toughness (6.1 MPa m 1/2 )-almost three times that of nanocrystalline alumina. Observation of cracks emanating from Vickers indents, as well as bend specimen fracture surfaces, reveal the operation of ductile phase toughening in the Nb-Al 2 O 3 nanocomposites. Further addition of 5 vol.% SWCNTs to the 10 vol.%Nb-Al 2 O 3 revealed a more porous structure and less impressive fracture toughness-having an indentation and bend fracture toughness of 2.9 MPa m 1/2 and 3.3 MPa m 1/2 , respectively

  10. Testing the accuracy of a Bayesian central-dose model for single-grain OSL, using known-age samples

    DEFF Research Database (Denmark)

    Guerin, Guillaume; Combès, Benoit; Lahaye, Christelle

    2015-01-01

    remains a difficult task, given the typically considerable dispersion in equivalent dose values measured by OSL - and the numerous sources of such dispersion in measurements. Here, we present the study of 19 samples for which independent age control is available, and whose ages range from 2 to 46ka. Based......-grain OSL and reference ages is about twice as large for the standard approach (12%) as with the Bayesian model (7%). Statistical tests show that, based on our (limited) dataset, the difference between the two models seems to be significant for samples in the age range 4-46ka. Finally, the influence...... on multi-grain OSL age estimates, these samples are presumed to have been both well-bleached at burial, and unaffected by mixing after deposition. Two ways of estimating single-grain ages are then compared: the standard approach on the one hand, consisting of applying the Central Age Model to De values...

  11. Criterion for traffic phases in single vehicle data and empirical test of a microscopic three-phase traffic theory

    International Nuclear Information System (INIS)

    Kerner, Boris S; Klenov, Sergey L; Hiller, Andreas

    2006-01-01

    Based on empirical and numerical microscopic analyses, the physical nature of a qualitatively different behaviour of the wide moving jam phase in comparison with the synchronized flow phase-microscopic traffic flow interruption within the wide moving jam phase-is found. A microscopic criterion for distinguishing the synchronized flow and wide moving jam phases in single vehicle data measured at a single freeway location is presented. Based on this criterion, empirical microscopic classification of different local congested traffic states is performed. Simulations made show that the microscopic criterion and macroscopic spatiotemporal objective criteria lead to the same identification of the synchronized flow and wide moving jam phases in congested traffic. Microscopic models in the context of three-phase traffic theory have been tested based on the microscopic criterion for the phases in congested traffic. It is found that microscopic three-phase traffic models can explain both microscopic and macroscopic empirical congested pattern features. It is obtained that microscopic frequency distributions for vehicle speed difference as well as fundamental diagrams and speed correlation functions can depend on the spatial co-ordinate considerably. It turns out that microscopic optimal velocity (OV) functions and time headway distributions are not necessarily qualitatively different, even if local congested traffic states are qualitatively different. The reason for this is that important spatiotemporal features of congested traffic patterns are lost in these as well as in many other macroscopic and microscopic traffic characteristics, which are widely used as the empirical basis for a test of traffic flow models, specifically, cellular automata traffic flow models

  12. Development and testing of single-shell tank waste retrieval technologies: Milestone M-45-01 summary report

    International Nuclear Information System (INIS)

    Shen, E.J.

    1994-08-01

    This report summarizes the activities undertaken to develop single-shell tank (SST) waste retrieval technology and complete scale-model testing. Completion of these activities fulfills the commitment of Milestone M-45-01 of the Hanford Federal Facility Agreement and Consent Order (the Tri-Party Agreement). Initial activities included engineering studies that compiled and evaluated data on all known retrieval technologies. Based on selection criteria incorporating regulatory, safety, and operational issues, several technologies were selected for further evaluation and testing. The testing ranged from small-scale, bench-top evaluations of individual technologies to full-scale integrated tests of multiple subsystems operating concurrently as a system using simulated wastes. The current baseline retrieval method for SSTs is hydraulic sluicing. This method has been used successfully in the past to recover waste from SSTs. Variations of this hydraulic or ''past practice'' sluicing may be used to retrieve the waste from the majority of the SSTs. To minimize the potential for releases to the soil, arm-based retrieval systems may be used to recover waste from tanks that are known or suspected to have leaked. Both hydraulic sluicing and arm-based retrieval will be demonstrated in the first SST. Hydraulic sluicing is expected to retrieve most of the waste, and arm-based retrieval will retrieve wastes that remain after sluicing. Subsequent tanks will be retrieved by either hydraulic sluicing or arm-based methods, but not both. The method will be determined by waste characterization, tank integrity (leak status), and presence of in-tank hardware. Currently, it is assumed that approximately 75% of all SSTs will be retrieved by hydraulic sluicing and the remaining tanks by arm-based methods

  13. Fractional Models Simulating Non-Fickian Behavior in Four-Stage Single-Well Push-Pull Tests

    Science.gov (United States)

    Chen, Kewei; Zhan, Hongbin; Yang, Qiang

    2017-11-01

    Four-stage single-well push-pull (SWPP) tracer tests, including injection, chasing, resting, and pumping, were conducted in a fractured aquifer at Newark basin. An anomalous transport phenomenon observed in the SWPP tests is the linear decline of breakthrough curves (BTCs) at late time with slope of -1.8 in log-log plots. A time-dependent fractional model is developed to interpret the anomalous transport behavior. This model considers a time-dependent power law memory function and a time-dependent fractional advection-dispersion operator. The fractional advection-dispersion equations (fADE) are solved in a radial coordinate system using the implicit Euler method. A semi-analytical solution of the first-order rate-limited mobile-immobile model (FORMIM) is derived for comparison. It is found that both the nonlocal transport in time and space can produce the long-tailed BTC. A smaller time-fractional or space-fractional index leads to a lower peak concentration and a larger late-time slope. The mass distribution of the fractional-in-space (FS) model exhibits power law decline at the leading plume edge. Early breakthrough during pumping is not observed because the mobile mass at the start of pumping is nonzero and more concentrated near the wellbore. The capacity ratio is an important factor that affects the peak concentration. A larger capacity ratio leads to greater peak concentration. A smaller time-fractional index in the injection, chasing, or resting stage will move the BTC downward and the slope of the late time BTC is determined by the space-fractional index over all stages and the time-fractional index in the pumping stage. The capability of the existing models to recover the BTC of the SWPP test is discussed and some guidelines for how to choose the appropriate model to interpret the SWPP test data are proposed.

  14. Evaluating a Pre-session Exercise in a Standalone Information Literacy Class

    Directory of Open Access Journals (Sweden)

    Joseph E. Goetz

    2015-12-01

    Full Text Available In this study, researchers evaluate a homework exercise assigned before a standalone information literacy session. Students in a Master of Education program completed a worksheet using the ERIC database thesaurus. The researchers conducted pre- and posttests within a single library session to assess student learning, using a control group for comparison. The treatment group did not demonstrate better thesaurus skills than students who had regular library instruction alone, but results pointed the way to targeted improvements of pre-session learning materials. This approach could inform other information literacy homework applications such as flipping the classroom.

  15. Test Standard Revision Update: JESD57, "Procedures for the Measurement of Single-Event Effects in Semiconductor Devices from Heavy-Ion Irradiation"

    Science.gov (United States)

    Lauenstein, Jean-Marie

    2015-01-01

    The JEDEC JESD57 test standard, Procedures for the Measurement of Single-Event Effects in Semiconductor Devices from Heavy-Ion Irradiation, is undergoing its first revision since 1996. In this talk, we place this test standard into context with other relevant radiation test standards to show its importance for single-event effect radiation testing for space applications. We show the range of industry, government, and end-user party involvement in the revision. Finally, we highlight some of the key changes being made and discuss the trade-space in which setting standards must be made to be both useful and broadly adopted.

  16. Session-RPE for quantifying the load of different youth basketball training sessions.

    Science.gov (United States)

    Lupo, C; Tessitore, A; Gasperi, L; Gomez, Mar

    2017-03-01

    The aim of the study was to evaluate youth basketball training, verifying the reliability of the session-RPE method in relation to session duration (basketball players (age, 16.5±0.5 years; height, 195.5±6.75 cm; body mass, 93.9±10.9 kg; and body mass index, 23.6±2.8 kg.m -2 ) were monitored (HR, type and duration of workouts) during 15 (66 individual) training sessions (80±26 minutes). Edwards' HR method was used as a reference measure of internal training load (ITL); the CR-10 RPE scale was administered 30 minutes after the end of each session. The results obtained showed that all comparisons between different session durations and workout portions revealed effects in term of Edwards' ITLs except for warm-up portions. Moderate to strong relationships between Edwards' and session- RPE methods emerged for all sessions (r = .85, P basketball players can successfully use session-RPE to monitor the ITL, regardless of session durations and workout portions.

  17. Single step modified ink staining for Tzanck test: quick detection of herpetic giant cells in Tzanck smear.

    Science.gov (United States)

    Mizutani, Hitoshi; Akeda, Tomoko; Yamanaka, Kei-Ichi; Isoda, Kenichi; Gabazza, Esteban C

    2012-02-01

    Tzanck test has been recently re-evaluated as a method for the diagnosis of herpes virus infection. Giemsa staining for the Tzanck test is time-consuming and laborious. There is a need to develop simple and quick staining methods for bedside diagnosis of this disease. We report a single step and quick method for staining herpes giant cells in Tzanck smears using routinely available inks and physiological saline. A keratinocyte cell line (HaCaT) was cultured on a slide glass and stained with various commercially available blue, blue-black and black inks serially diluted with physiological saline. Clinical smear samples from herpes lesions were also stained with these solutions without specific pretreatment. The nuclei of HaCaT were clearly stained showing high contrast with the cytoplasm using 5% Parker-Quink blue-black ink saline solution. Concentration of ink solution higher or lower than 5% resulted in less contrast. Blue or black inks or other manufacturers' inks can also be used, but staining of the cultured keratinocytes was less clear. Smear of clinical samples from herpes lesions were also stained with 5% ink solution. The nuclei of the multinucleated giant cells were clearly stained, and the sample could be immediately used for microscopic examination. One step staining of Tzanck smear using this diluted ink solution is an inexpensive and a convenient bedside diagnostic tool for the dermatologist. © 2011 Japanese Dermatological Association.

  18. Accurate single nucleotide variant detection in viral populations by combining probabilistic clustering with a statistical test of strand bias

    Science.gov (United States)

    2013-01-01

    Background Deep sequencing is a powerful tool for assessing viral genetic diversity. Such experiments harness the high coverage afforded by next generation sequencing protocols by treating sequencing reads as a population sample. Distinguishing true single nucleotide variants (SNVs) from sequencing errors remains challenging, however. Current protocols are characterised by high false positive rates, with results requiring time consuming manual checking. Results By statistical modelling, we show that if multiple variant sites are considered at once, SNVs can be called reliably from high coverage viral deep sequencing data at frequencies lower than the error rate of the sequencing technology, and that SNV calling accuracy increases as true sequence diversity within a read length increases. We demonstrate these findings on two control data sets, showing that SNV detection is more reliable on a high diversity human immunodeficiency virus sample as compared to a moderate diversity sample of hepatitis C virus. Finally, we show that in situations where probabilistic clustering retains false positive SNVs (for instance due to insufficient sample diversity or systematic errors), applying a strand bias test based on a beta-binomial model of forward read distribution can improve precision, with negligible cost to true positive recall. Conclusions By combining probabilistic clustering (implemented in the program ShoRAH) with a statistical test of strand bias, SNVs may be called from deeply sequenced viral populations with high accuracy. PMID:23879730

  19. Testing pollen of single and stacked insect-resistant Bt-maize on in vitro reared honey bee larvae.

    Directory of Open Access Journals (Sweden)

    Harmen P Hendriksma

    Full Text Available The ecologically and economic important honey bee (Apis mellifera is a key non-target arthropod species in environmental risk assessment (ERA of genetically modified (GM crops. Honey bee larvae are directly exposed to transgenic products by the consumption of GM pollen. But most ERA studies only consider responses of adult bees, although Bt-proteins primarily affect the larval phases of target organisms. We adopted an in vitro larvae rearing system, to assess lethal and sublethal effects of Bt-pollen consumption in a standardized eco-toxicological bioassay. The effects of pollen from two Bt-maize cultivars, one expressing a single and the other a total of three Bt-proteins, on the survival and prepupae weight of honey bee larvae were analyzed. The control treatments included pollen from three non-transgenic maize varieties and of Heliconia rostrata. Three days old larvae were fed the realistic exposure dose of 2 mg pollen within the semi-artificial diet. The larvae were monitored over 120 h, until the prepupal stage, where larvae terminate feeding and growing. Neither single nor stacked Bt-maize pollen showed an adverse effect on larval survival and the prepupal weight. In contrast, feeding of H. rostrata pollen caused significant toxic effects. The results of this study indicate that pollen of the tested Bt-varieties does not harm the development of in vitro reared A. mellifera larvae. To sustain the ecosystem service of pollination, Bt-impact on A. mellifera should always be a crucial part of regulatory biosafety assessments. We suggest that our approach of feeding GM pollen on in vitro reared honey bee larvae is well suited of becoming a standard bioassay in regulatory risk assessments schemes of GM crops.

  20. Testing pollen of single and stacked insect-resistant Bt-maize on in vitro reared honey bee larvae.

    Science.gov (United States)

    Hendriksma, Harmen P; Härtel, Stephan; Steffan-Dewenter, Ingolf

    2011-01-01

    The ecologically and economic important honey bee (Apis mellifera) is a key non-target arthropod species in environmental risk assessment (ERA) of genetically modified (GM) crops. Honey bee larvae are directly exposed to transgenic products by the consumption of GM pollen. But most ERA studies only consider responses of adult bees, although Bt-proteins primarily affect the larval phases of target organisms. We adopted an in vitro larvae rearing system, to assess lethal and sublethal effects of Bt-pollen consumption in a standardized eco-toxicological bioassay. The effects of pollen from two Bt-maize cultivars, one expressing a single and the other a total of three Bt-proteins, on the survival and prepupae weight of honey bee larvae were analyzed. The control treatments included pollen from three non-transgenic maize varieties and of Heliconia rostrata. Three days old larvae were fed the realistic exposure dose of 2 mg pollen within the semi-artificial diet. The larvae were monitored over 120 h, until the prepupal stage, where larvae terminate feeding and growing. Neither single nor stacked Bt-maize pollen showed an adverse effect on larval survival and the prepupal weight. In contrast, feeding of H. rostrata pollen caused significant toxic effects. The results of this study indicate that pollen of the tested Bt-varieties does not harm the development of in vitro reared A. mellifera larvae. To sustain the ecosystem service of pollination, Bt-impact on A. mellifera should always be a crucial part of regulatory biosafety assessments. We suggest that our approach of feeding GM pollen on in vitro reared honey bee larvae is well suited of becoming a standard bioassay in regulatory risk assessments schemes of GM crops.

  1. Poster session in instructional technology course

    Science.gov (United States)

    Diniaty, Artina; Fauzi'ah, Lina; Wulan Febriana, Beta; Arlianty, Widinda Normalia

    2017-12-01

    Instructional technology course must be studied by students in order to 1) understand the role of technology in learning, 2) capable of analyzing advantages and disadvantages of using technology in teaching, 3) capable of performing technology in teaching. A poster session in instructional technology course was performed to 1) enhance students' interest in this course and develop students' creativity. The step of this research includes: planning, implementation, and evaluation. The result showed that students' responses towards poster session in instructional technology course were good.

  2. Summary of Session 2 "Machine Studies"

    CERN Document Server

    Assmann, R W

    2012-01-01

    This document summarizes the talks and discussion that took place in the second session of the Chamonix 2012 workshop concerning results from machine studies performed in 2011. The session consisted of the following presentations: “LHC experience with different bunch spacings” by G. Rumolo; “Observations of beam-beam effects in MDs in 2011” by W. Herr; “Beam-induced heating/ bunch length/RF and lessons for 2012” by E. Metral; “Lessons in beam diagnostics” by R. Jones; “Quench margins” by M. Sapinski; “First demonstration with beam of the Achromatic Telescopic Squeeze (ATS)” by S. Fartoukh.

  3. MASH test 3-11 of the TxDOT single slope bridge rail (type SSTR) on pan-formed bridge deck

    Science.gov (United States)

    2011-03-01

    The objective of this crash test was to determine whether the TxDOT Single Slope Traffic Rail (Type : SSTR) would perform acceptably on a pan-formed deck when tested according to the guidelines set forth in : Manual for Assessing Safety Hardware (MAS...

  4. Interpretation of Flow Logs from Nevada Test Site Boreholes to Estimate Hydraulic Conductivity Using Numerical Simulations Constrained by Single-Well Aquifer Tests

    Science.gov (United States)

    Garcia, C. Amanda; Halford, Keith J.; Laczniak, Randell J.

    2010-01-01

    Hydraulic conductivities of volcanic and carbonate lithologic units at the Nevada Test Site were estimated from flow logs and aquifer-test data. Borehole flow and drawdown were integrated and interpreted using a radial, axisymmetric flow model, AnalyzeHOLE. This integrated approach is used because complex well completions and heterogeneous aquifers and confining units produce vertical flow in the annular space and aquifers adjacent to the wellbore. AnalyzeHOLE simulates vertical flow, in addition to horizontal flow, which accounts for converging flow toward screen ends and diverging flow toward transmissive intervals. Simulated aquifers and confining units uniformly are subdivided by depth into intervals in which the hydraulic conductivity is estimated with the Parameter ESTimation (PEST) software. Between 50 and 150 hydraulic-conductivity parameters were estimated by minimizing weighted differences between simulated and measured flow and drawdown. Transmissivity estimates from single-well or multiple-well aquifer tests were used to constrain estimates of hydraulic conductivity. The distribution of hydraulic conductivity within each lithology had a minimum variance because estimates were constrained with Tikhonov regularization. AnalyzeHOLE simulated hydraulic-conductivity estimates for lithologic units across screened and cased intervals are as much as 100 times less than those estimated using proportional flow-log analyses applied across screened intervals only. Smaller estimates of hydraulic conductivity for individual lithologic units are simulated because sections of the unit behind cased intervals of the wellbore are not assumed to be impermeable, and therefore, can contribute flow to the wellbore. Simulated hydraulic-conductivity estimates vary by more than three orders of magnitude across a lithologic unit, indicating a high degree of heterogeneity in volcanic and carbonate-rock units. The higher water transmitting potential of carbonate-rock units relative

  5. Regional long-term production modeling from a single well test, Mount Elbert Gas Hydrate Stratigraphic Test Well, Alaska North Slope

    Science.gov (United States)

    Anderson, B.J.; Kurihara, M.; White, M.D.; Moridis, G.J.; Wilson, S.J.; Pooladi-Darvish, M.; Gaddipati, M.; Masuda, Y.; Collett, T.S.; Hunter, R.B.; Narita, H.; Rose, K.; Boswell, R.

    2011-01-01

    salinity (5 ppt), and formation temperature (3.3-3.9 ??C). This paper presents the approach and results of extrapolating regional forward production modeling from history-matching efforts on the results from a single well test. ?? 2010 Elsevier Ltd.

  6. Regional long-term production modeling from a single well test, Mount Elbert Gas Hydrate Stratigraphic Test Well, Alaska North Slope

    Energy Technology Data Exchange (ETDEWEB)

    Anderson, Brian J.; Kurihara, Masanori; White, Mark D.; Moridis, George J.; Wilson, Scott J.; Pooladi-Darvish, Mehran; Gaddipati, Manohar; Masuda, Yoshihiro; Collett, Timothy S.; Hunter, Robert B.; Narita, Hideo; Rose, Kelly; Boswell, Ray

    2011-02-01

    water salinity (5 ppt), and formation temperature (3.3–3.9 °C). Finally, this paper presents the approach and results of extrapolating regional forward production modeling from history-matching efforts on the results from a single well test.

  7. Interpretation of Flow Logs from Nevada Test Site Boreholes to Estimate Hydraulic conductivity Using Numerical Simulations Constrained by Single-Well Aquifer Tests

    Energy Technology Data Exchange (ETDEWEB)

    Garcia, C. Amanda; Halford, Keith J.; Laczniak, Randell J.

    2010-02-12

    Hydraulic conductivities of volcanic and carbonate lithologic units at the Nevada Test Site were estimated from flow logs and aquifer-test data. Borehole flow and drawdown were integrated and interpreted using a radial, axisymmetric flow model, AnalyzeHOLE. This integrated approach is used because complex well completions and heterogeneous aquifers and confining units produce vertical flow in the annular space and aquifers adjacent to the wellbore. AnalyzeHOLE simulates vertical flow, in addition to horizontal flow, which accounts for converging flow toward screen ends and diverging flow toward transmissive intervals. Simulated aquifers and confining units uniformly are subdivided by depth into intervals in which the hydraulic conductivity is estimated with the Parameter ESTimation (PEST) software. Between 50 and 150 hydraulic-conductivity parameters were estimated by minimizing weighted differences between simulated and measured flow and drawdown. Transmissivity estimates from single-well or multiple-well aquifer tests were used to constrain estimates of hydraulic conductivity. The distribution of hydraulic conductivity within each lithology had a minimum variance because estimates were constrained with Tikhonov regularization. AnalyzeHOLE simulated hydraulic-conductivity estimates for lithologic units across screened and cased intervals are as much as 100 times less than those estimated using proportional flow-log analyses applied across screened intervals only. Smaller estimates of hydraulic conductivity for individual lithologic units are simulated because sections of the unit behind cased intervals of the wellbore are not assumed to be impermeable, and therefore, can contribute flow to the wellbore. Simulated hydraulic-conductivity estimates vary by more than three orders of magnitude across a lithologic unit, indicating a high degree of heterogeneity in volcanic and carbonate-rock units. The higher water transmitting potential of carbonate-rock units relative

  8. IAEA General Conference begins annual session

    International Nuclear Information System (INIS)

    2001-01-01

    The document gives general information about the opening and the programme of the 45th regular session of the IAEA General Conference (17-21 September 2001, Austria Center Vienna). The conference is attended by ministers and high-level governmental representatives from 132 Member States of the IAEA

  9. Declarative interpretations of session-based concurrency

    DEFF Research Database (Denmark)

    Cano, Mauricio; Rueda, Camilo; López-Acosta, Hugo-Andrés

    2015-01-01

    Session-based concurrency is a type-based approach to the analysis of communication-intensive systems. Correct behavior in these systems may be specified in an operational or declarative style: the former defines how interactions are structured; the latter defines governing conditions...

  10. Foundations of Session Types and Behavioural Contracts

    DEFF Research Database (Denmark)

    Huttel, Hans; Lanese, Ivan; Vasconcelos, Vasco

    2016-01-01

    of interaction using expressive type languages, so types can be used to determine automatically whether the component interacts correctly with other components. Two related important notions of behavioural types are those of session types and behavioural contracts. This article surveys the main accomplishments...

  11. Posters. [Poster Session at AHRD Conference, 2001].

    Science.gov (United States)

    2001

    The first of the papers in this poster session, "Developing the Employment Brand: Targeting MBA Campus Hires" (Diane M. Bergeron), posits that employment branding benefits both individuals and organizations. It functions as a campus recruiting tool in a competitive labor market and communicates the organization's values and work…

  12. An Erlang Implementation of Multiparty Session Actors

    Directory of Open Access Journals (Sweden)

    Simon Fowler

    2016-08-01

    Full Text Available By requiring co-ordination to take place using explicit message passing instead of relying on shared memory, actor-based programming languages have been shown to be effective tools for building reliable and fault-tolerant distributed systems. Although naturally communication-centric, communication patterns in actor-based applications remain informally specified, meaning that errors in communication are detected late, if at all. Multiparty session types are a formalism to describe, at a global level, the interactions between multiple communicating entities. This article describes the implementation of a prototype framework for monitoring Erlang/OTP gen_server applications against multiparty session types, showing how previous work on multiparty session actors can be adapted to a purely actor-based language, and how monitor violations and termination of session participants can be reported in line with the Erlang mantra of "let it fail". Finally, the framework is used to implement two case studies: an adaptation of a freely-available DNS server, and a chat server.

  13. Organizing a Practice Session for Maximum Effectiveness

    Science.gov (United States)

    DeGroot, Joanna

    2009-01-01

    According to Jason Paulk, director of choral activities at Eastern New Mexico University, progress is made during those in-between times and that progress magnifies with efficient time spent alone. Paulk is a firm believer in the importance of singers organizing their practice sessions, and he details some effective organization methods, including…

  14. Clinical experience with a single-nucleotide polymorphism-based non-invasive prenatal test for five clinically significant microdeletions.

    Science.gov (United States)

    Martin, K; Iyengar, S; Kalyan, A; Lan, C; Simon, A L; Stosic, M; Kobara, K; Ravi, H; Truong, T; Ryan, A; Demko, Z P; Benn, P

    2018-02-01

    Single-nucleotide polymorphism (SNP)-based non-inv