WorldWideScience

Sample records for single standardized test

  1. LHC BLM Single Channel Connectivity Test using the Standard Installation

    CERN Document Server

    Emery, J; Effinger, E; Ferioli, G; Zamantzas, C; Ikeda, H; Verhagen, E

    2009-01-01

    For the LHC Beam Loss Measurement system (BLM), the high voltage supply of the ionisation chambers and the secondary emission detectors is used to test their connectivity. A harmonic modulation of 0.03 Hz results in a current signal of about 100pA measured by the beam loss acquisition electronics. The signal is analyzed and the measured amplitude and phase are compared with individual channel limits for the 4000 channels. It is foreseen to execute an automatic procedure for all channels every 12 hours which takes about 20 minutes. The paper will present the design of the system, the circuit simulations, measurements of systematic dependencies of different channels and the reproducibility of the amplitude and phase measurements.

  2. A single standard for in-place testing of DOE HEPA filters - not

    Energy Technology Data Exchange (ETDEWEB)

    Mokler, B.V. [Los Alamos National Laboratory, NM (United States)

    1995-02-01

    This article is a review of arguments against the use of a single standard for in-place testing of DOE HEPA filters. The author feels that the term `standard` entails mandatory compliance. Additionally, the author feels that the variety of DOE HEPA systems requiring in-place testing is such that the guidance for testing must be written in a permissive fashion, allowing options and alternatives. With this in mind, it is not possible to write a single document entailing mandatory compliance for all DOE facilities.

  3. A single standard for in-place testing of DOE HEPA filters - not

    International Nuclear Information System (INIS)

    Mokler, B.V.

    1995-01-01

    This article is a review of arguments against the use of a single standard for in-place testing of DOE HEPA filters. The author feels that the term 'standard' entails mandatory compliance. Additionally, the author feels that the variety of DOE HEPA systems requiring in-place testing is such that the guidance for testing must be written in a permissive fashion, allowing options and alternatives. With this in mind, it is not possible to write a single document entailing mandatory compliance for all DOE facilities

  4. Standard test method for isotopic analysis of uranium hexafluoride by double standard single-collector gas mass spectrometer method

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This is a quantitative test method applicable to determining the mass percent of uranium isotopes in uranium hexafluoride (UF6) samples with 235U concentrations between 0.1 and 5.0 mass %. 1.2 This test method may be applicable for the entire range of 235U concentrations for which adequate standards are available. 1.3 This test method is for analysis by a gas magnetic sector mass spectrometer with a single collector using interpolation to determine the isotopic concentration of an unknown sample between two characterized UF6 standards. 1.4 This test method is to replace the existing test method currently published in Test Methods C761 and is used in the nuclear fuel cycle for UF6 isotopic analyses. 1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appro...

  5. Standard Test Method for Isotopic Analysis of Uranium Hexafluoride by Single-Standard Gas Source Multiple Collector Mass Spectrometer Method

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2011-01-01

    1.1 This test method is applicable to the isotopic analysis of uranium hexafluoride (UF6) with 235U concentrations less than or equal to 5 % and 234U, 236U concentrations of 0.0002 to 0.1 %. 1.2 This test method may be applicable to the analysis of the entire range of 235U isotopic compositions providing that adequate Certified Reference Materials (CRMs or traceable standards) are available. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety health practices and determine the applicability of regulatory limitations prior to use.

  6. Standardized testing with chlorhexidine in perioperative allergy – a large single-centre evaluation

    DEFF Research Database (Denmark)

    Schjørring Opstrup, Morten; Malling, Hans-Jørgen; Krøigaard, Mogens

    2014-01-01

    BACKGROUND: Perioperative allergic reactions to chlorhexidine are often severe and easily overlooked. Although rare, the prevalence remains unknown. Correct diagnosis is crucial, but no validated provocation model exists, and other diagnostic tests have never been evaluated. The aims were...... to estimate 1) the prevalence of chlorhexidine allergy and 2) the specificity and sensitivity for diagnostic tests for chlorhexidine allergy. METHODS: We included all patients investigated for suspected perioperative allergic reactions in the Danish Anaesthesia Allergy Centre during 2004-2012. The following...... the diameter of negative control. Chlorhexidine allergy was post hoc defined as a relevant clinical reaction to chlorhexidine combined with two or more positive tests. Based on this definition, sensitivity and specificity were estimated for each test. RESULTS: In total, 22 out of 228 patients (9.6%) met...

  7. Standardized testing with chlorhexidine in perioperative allergy--a large single-centre evaluation.

    Science.gov (United States)

    Opstrup, M S; Malling, H-J; Krøigaard, M; Mosbech, H; Skov, P S; Poulsen, L K; Garvey, L H

    2014-10-01

    Perioperative allergic reactions to chlorhexidine are often severe and easily overlooked. Although rare, the prevalence remains unknown. Correct diagnosis is crucial, but no validated provocation model exists, and other diagnostic tests have never been evaluated. The aims were to estimate (i) the prevalence of chlorhexidine allergy in perioperative allergy and (ii) the specificity and sensitivity for diagnostic tests for chlorhexidine allergy. We included all patients investigated for suspected perioperative allergic reactions in the Danish Anaesthesia Allergy Centre during 2004-2012. The following tests were performed: specific IgE (Immunocap® ; Phadia AB, Sweden), histamine release test (HR) (RefLab ApS, Denmark), skin prick test (SPT) and intradermal test (IDT). Positivity criteria were as follows: specific IgE >0.35 kUA/l; HR class 1-12; SPT mean wheal diameter ≥3 mm; IDT mean wheal diameter ≥ twice the diameter of negative control. Chlorhexidine allergy was post hoc defined as a relevant clinical reaction to chlorhexidine combined with two or more positive tests. Based on this definition, sensitivity and specificity were estimated for each test. In total, 22 of 228 patients (9.6%) met the definition of allergy to chlorhexidine. Estimated sensitivity and specificity were as follows: specific IgE (sensitivity 100% and specificity 97%), HR (sensitivity 55% and specificity 99%), SPT (sensitivity 95% and specificity 97%) and IDT (sensitivity 68% and specificity 100%). In patients investigated for suspected perioperative allergic reactions, 9.6% were diagnosed with allergy to chlorhexidine. Using our definition of chlorhexidine allergy, the highest combined estimated sensitivity and specificity was found for specific IgE and SPT. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  8. Test Standard Revision Update: JESD57, "Procedures for the Measurement of Single-Event Effects in Semiconductor Devices from Heavy-Ion Irradiation"

    Science.gov (United States)

    Lauenstein, Jean-Marie

    2015-01-01

    The JEDEC JESD57 test standard, Procedures for the Measurement of Single-Event Effects in Semiconductor Devices from Heavy-Ion Irradiation, is undergoing its first revision since 1996. In this talk, we place this test standard into context with other relevant radiation test standards to show its importance for single-event effect radiation testing for space applications. We show the range of industry, government, and end-user party involvement in the revision. Finally, we highlight some of the key changes being made and discuss the trade-space in which setting standards must be made to be both useful and broadly adopted.

  9. Standard practice for measurement of the glass dissolution rate using the single-pass flow-through test method

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This practice describes a single-pass flow-through (SPFT) test method that can be used to measure the dissolution rate of a homogeneous silicate glass, including nuclear waste glasses, in various test solutions at temperatures less than 100°C. Tests may be conducted under conditions in which the effects from dissolved species on the dissolution rate are minimized to measure the forward dissolution rate at specific values of temperature and pH, or to measure the dependence of the dissolution rate on the concentrations of various solute species. 1.2 Tests are conducted by pumping solutions in either a continuous or pulsed flow mode through a reaction cell that contains the test specimen. Tests must be conducted at several solution flow rates to evaluate the effect of the flow rate on the glass dissolution rate. 1.3 This practice excludes static test methods in which flow is simulated by manually removing solution from the reaction cell and replacing it with fresh solution. 1.4 Tests may be conducted wit...

  10. Testing the Standard Model

    CERN Document Server

    Riles, K

    1998-01-01

    The Large Electron Project (LEP) accelerator near Geneva, more than any other instrument, has rigorously tested the predictions of the Standard Model of elementary particles. LEP measurements have probed the theory from many different directions and, so far, the Standard Model has prevailed. The rigour of these tests has allowed LEP physicists to determine unequivocally the number of fundamental 'generations' of elementary particles. These tests also allowed physicists to ascertain the mass of the top quark in advance of its discovery. Recent increases in the accelerator's energy allow new measurements to be undertaken, measurements that may uncover directly or indirectly the long-sought Higgs particle, believed to impart mass to all other particles.

  11. Environmental Stress Testing of the Single Sample Cylinder: A Proven Consensus Standard for Internal Gas Analysis (IGA) or Residual Gas Analysis (RGA)

    Science.gov (United States)

    Schuessler, Philipp WH

    2010-01-01

    In August 2008, Schuessler Consulting was contracted by NASA GSFC in support of the NASA Electronic Parts and Packaging (NEPP) program to perform two separate studies on moisture laden air in a stainless steel cylinder that had been designed to become a consensus standard for Test Method 1018. This Test Method was originally released for hybrids under Mil. Std. 883 but was quickly utilized on other microelectronic devices under the auspice of Mil. Std. 750. The cylinder had subsequently been fabricated for the 750 community. It was back-filled with moist air and subsequently analyzed over a period of time under a previous NASA contract. It had been shown that moisture in the 4000 - 5000 ppm range could be analyzed rather precisely with a mass spectrometer, commonly referred to as a Residual Gas Analyzer (RGA). The scope of this study was to ascertain if the composition and precision varied as a function of thermal shock at sub-zero temperatures and whether there was consensus when the standard was submitted to other RGA units. It was demonstrated and published that the consensus standard would yield precise RGA data for moisture within +/- 1% when optimized for a given RGA unit. It has been subsequently shown in this study at Oneida Research Services, that sub-zero storage did not affect that precision when a well-defined protocol for the analysis was followed. The consensus standard was taken to a second facility for analysis where it was found that moisture adsorption on the transfer lines caused precision to drop to +/- 12%. The Single Sample Cylinder (SSC) is a one liter stainless steel cylinder with associated sampling valves and has considerable weight and volume. But this considerable size allows for approximately 300 gas samples of the same composition to be delivered to any RGA unit. Lastly, a smaller cylinder, approximately 75 cc, of a second consensus standard was fabricated and tested with a different mix of fixed gases where moisture was kept in the

  12. Tests on standard concrete samples

    CERN Multimedia

    CERN PhotoLab

    1973-01-01

    Compression and tensile tests on standard concrete samples. The use of centrifugal force in tensile testing has been developed by the SB Division and the instruments were built in the Central workshops.

  13. Standard Test Method for Sandwich Corrosion Test

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This test method defines the procedure for evaluating the corrosivity of aircraft maintenance chemicals, when present between faying surfaces (sandwich) of aluminum alloys commonly used for aircraft structures. This test method is intended to be used in the qualification and approval of compounds employed in aircraft maintenance operations. 1.2 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information. 1.3 This standard may involve hazardous materials, operations, and equipment. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific hazard statements appear in Section 9.

  14. SINGLE HEATER TEST FINAL REPORT

    Energy Technology Data Exchange (ETDEWEB)

    J.B. Cho

    1999-05-01

    The Single Heater Test is the first of the in-situ thermal tests conducted by the U.S. Department of Energy as part of its program of characterizing Yucca Mountain in Nevada as the potential site for a proposed deep geologic repository for the disposal of spent nuclear fuel and high-level nuclear waste. The Site Characterization Plan (DOE 1988) contained an extensive plan of in-situ thermal tests aimed at understanding specific aspects of the response of the local rock-mass around the potential repository to the heat from the radioactive decay of the emplaced waste. With the refocusing of the Site Characterization Plan by the ''Civilian Radioactive Waste Management Program Plan'' (DOE 1994), a consolidated thermal testing program emerged by 1995 as documented in the reports ''In-Situ Thermal Testing Program Strategy'' (DOE 1995) and ''Updated In-Situ Thermal Testing Program Strategy'' (CRWMS M&O 1997a). The concept of the Single Heater Test took shape in the summer of 1995 and detailed planning and design of the test started with the beginning fiscal year 1996. The overall objective of the Single Heater Test was to gain an understanding of the coupled thermal, mechanical, hydrological, and chemical processes that are anticipated to occur in the local rock-mass in the potential repository as a result of heat from radioactive decay of the emplaced waste. This included making a priori predictions of the test results using existing models and subsequently refining or modifying the models, on the basis of comparative and interpretive analyses of the measurements and predictions. A second, no less important, objective was to try out, in a full-scale field setting, the various instruments and equipment to be employed in the future on a much larger, more complex, thermal test of longer duration, such as the Drift Scale Test. This ''shake down'' or trial aspect of the Single Heater Test applied

  15. SINGLE HEATER TEST FINAL REPORT

    International Nuclear Information System (INIS)

    J.B. Cho

    1999-01-01

    The Single Heater Test is the first of the in-situ thermal tests conducted by the U.S. Department of Energy as part of its program of characterizing Yucca Mountain in Nevada as the potential site for a proposed deep geologic repository for the disposal of spent nuclear fuel and high-level nuclear waste. The Site Characterization Plan (DOE 1988) contained an extensive plan of in-situ thermal tests aimed at understanding specific aspects of the response of the local rock-mass around the potential repository to the heat from the radioactive decay of the emplaced waste. With the refocusing of the Site Characterization Plan by the ''Civilian Radioactive Waste Management Program Plan'' (DOE 1994), a consolidated thermal testing program emerged by 1995 as documented in the reports ''In-Situ Thermal Testing Program Strategy'' (DOE 1995) and ''Updated In-Situ Thermal Testing Program Strategy'' (CRWMS M and O 1997a). The concept of the Single Heater Test took shape in the summer of 1995 and detailed planning and design of the test started with the beginning fiscal year 1996. The overall objective of the Single Heater Test was to gain an understanding of the coupled thermal, mechanical, hydrological, and chemical processes that are anticipated to occur in the local rock-mass in the potential repository as a result of heat from radioactive decay of the emplaced waste. This included making a priori predictions of the test results using existing models and subsequently refining or modifying the models, on the basis of comparative and interpretive analyses of the measurements and predictions. A second, no less important, objective was to try out, in a full-scale field setting, the various instruments and equipment to be employed in the future on a much larger, more complex, thermal test of longer duration, such as the Drift Scale Test. This ''shake down'' or trial aspect of the Single Heater Test applied not just to the hardware, but also to the teamwork and cooperation between

  16. Validation of a single nucleotide polymorphism (SNP) typing assay with 49 SNPs for forensic genetic testing in a laboratory accredited according to the ISO 17025 standard

    DEFF Research Database (Denmark)

    Børsting, Claus; Rockenbauer, Eszter; Morling, Niels

    2009-01-01

    cases and 33 twin cases were typed at least twice for the 49 SNPs. All electropherograms were analysed independently by two expert analysts prior to approval. Based on these results, detailed guidelines for analysis of the SBE products were developed. With these guidelines, the peak height ratio...... of a heterozygous allele call or the signal to noise ratio of a homozygous allele call is compared with previously obtained ratios. A laboratory protocol for analysis of SBE products was developed where allele calls with unusual ratios were highlighted to facilitate the analysis of difficult allele calls......A multiplex assay with 49 autosomal single nucleotide polymorphisms (SNPs) developed for human identification was validated for forensic genetic casework and accredited according to the ISO 17025 standard. The multiplex assay was based on the SNPforID 52plex SNP assay [J.J. Sanchez, C. Phillips, C...

  17. Single event upset test programs

    International Nuclear Information System (INIS)

    Russen, L.C.

    1984-11-01

    It has been shown that the heavy ions in cosmic rays can give rise to single event upsets in VLSI random access memory devices (RAMs). Details are given of the programs written to test 1K, 4K, 16K and 64K memories during their irradiation with heavy charged ions, in order to simulate the effects of cosmic rays in space. The test equipment, which is used to load the memory device to be tested with a known bit pattern, and subsequently interrogate it for upsets, or ''flips'', is fully described. (author)

  18. Single Event Effect (SEE) Test Planning 101

    Science.gov (United States)

    LaBel, Kenneth A.; Pellish, Jonathan; Berg, Melanie D.

    2011-01-01

    This is a course on SEE Test Plan development. It is an introductory discussion of the items that go into planning an SEE test that should complement the SEE test methodology used. Material will only cover heavy ion SEE testing and not proton, LASER, or other though many of the discussed items may be applicable. While standards and guidelines for how-to perform single event effects (SEE) testing have existed almost since the first cyclotron testing, guidance on the development of SEE test plans has not been as easy to find. In this section of the short course, we attempt to rectify this lack. We consider the approach outlined here as a "living" document: mission specific constraints and new technology related issues always need to be taken into account. We note that we will use the term "test planning" in the context of those items being included in a test plan.

  19. Computing tools for implementing standards for single-case designs.

    Science.gov (United States)

    Chen, Li-Ting; Peng, Chao-Ying Joanne; Chen, Ming-E

    2015-11-01

    In the single-case design (SCD) literature, five sets of standards have been formulated and distinguished: design standards, assessment standards, analysis standards, reporting standards, and research synthesis standards. This article reviews computing tools that can assist researchers and practitioners in meeting the analysis standards recommended by the What Works Clearinghouse: Procedures and Standards Handbook-the WWC standards. These tools consist of specialized web-based calculators or downloadable software for SCD data, and algorithms or programs written in Excel, SAS procedures, SPSS commands/Macros, or the R programming language. We aligned these tools with the WWC standards and evaluated them for accuracy and treatment of missing data, using two published data sets. All tools were tested to be accurate. When missing data were present, most tools either gave an error message or conducted analysis based on the available data. Only one program used a single imputation method. This article concludes with suggestions for an inclusive computing tool or environment, additional research on the treatment of missing data, and reasonable and flexible interpretations of the WWC standards. © The Author(s) 2015.

  20. The "Volvo Effect"--Questioning Standardized Tests.

    Science.gov (United States)

    Wesson, Kenneth A.

    2001-01-01

    Questions current emphasis on standardized tests and discusses several factors about the tests that should prompt reevaluation of their usefulness. Issues discussed include: development and design of standardized tests; the correlation between test scores and socioeconomic position; the discrepancy between test designs and accurate reflection of…

  1. Bibliography of non-destructive testing standards

    International Nuclear Information System (INIS)

    Venkataraman, L.; Khan, Subban

    1975-01-01

    A bibliography on non-destructive testing (NDT) standards issued by standards organisations of the U.K., the U.S.A., India, France and F.R. Germany and by the International Standards Organization has been compiled and arranged under the following topics: (1) radiographic testing (2) ultrasonic testing (3) eddy current testing (4) magnetic particle testing (5) liquid penetrant testing (6) magnetic testing and (7) NDT in general. The total number of standards listed in the bibliography is 195. (M.G.B.)

  2. Compendium of Single Event Effects (SEE) Test Results for COTS and Standard Electronics for Low Earth Orbit and Deep Space Applications

    Science.gov (United States)

    Reddell, Brandon; Bailey, Chuck; Nguyen, Kyson; O'Neill, Patrick; Gaza, Razvan; Patel, Chirag; Cooper, Jaime; Kalb, Theodore

    2017-01-01

    We present the results of SEE testing with high energy protons and with low and high energy heavy ions. This paper summarizes test results for components considered for Low Earth Orbit and Deep Space applications.

  3. Plain Talk About Standardized Tests. Research Report.

    Science.gov (United States)

    Ward, James G.; Gould, Jewell C.

    This handbook, in two parts, constitutes a manual prepared by the American Federation of Teachers, for improving teachers' use of standardized tests. Part I outlines basic concepts and issues surrounding standardized testing for teachers, parents and school administrators. The terms norm-referenced tests, criterion referenced tests, minimum…

  4. Standardized performance tests of collectors of solar thermal energy-a flat-plate collector with a single-tube serpentine flow distribution

    Science.gov (United States)

    Johnson, S.

    1976-01-01

    This preliminary data report gives basic test results of a flat-plate solar collector whose performance was determined in the NASA-Lewis solar simulator. The collector was tested over ranges of inlet temperatures, fluxes and coolant flow rates. Collector efficienty is correlated in terms of inlet temperature and flux level.

  5. Rock Testing Handbook (Test Standards 1993)

    Science.gov (United States)

    1993-01-01

    Chemistry , Houghton Minihn Co.. New (15) Leggeit, R. F., Geology and Engineering, McGraw-Hill Book Co., York, NY (1947). Inc._ New York, NY (1939). (38... tesied from the some setup using a large- diameter drill to advance between tests. The direction of loading necessarily coincides with the drill hole...Geological Survey Professional Paper 205-B (1945). Co., Chicago. IL (1939). (37) Hartman, R. J., Colloid Chemistry , Houghton Mifflin Co.. New (15) Leggett

  6. Determination of blood leukocyte concentration with constant volume acquisition on a flow cytometer is comparable to individualized single platform testing with beads as internal reference standard

    DEFF Research Database (Denmark)

    Hansen, Susan; Dahl, Ronald; Hoffmann, Hans Jürgen

    2008-01-01

    Flow cytometers have a constant flow rate. This enables flow cytometers to measure leukocyte concentrations in a determined volume by acquiring data at a fixed rate over a fixed time and is called constant volume acquisition (CVA). The volume aspirated by a FACS Calibur flow cytometer in 4 min...... at a high rate has a median of 163 microl (IQR 156-170) with TruCount tubes. Leukocyte concentrations of 26 healthy volunteers were measured twice on up to four occasions with a Bürker-Türk chamber, by single platform technology (SPT) with TruCount tubes and on the same data set using CVA. Total leukocyte...... concentrations determined by CVA correlated better with measurements in a Bürker-Türk (BT) chamber than with SPT. Concentrations determined with CVA were 1.86% higher than with BT whereas SPT data were 5.35% higher than BT (pconcentrations

  7. No Associations Between Single Nucleotide Polymorphisms in Corticoid Receptor Genes and Heart Rate and Cortisol Responses to a Standardized Social Stress Test in Adolescents : The TRAILS Study

    NARCIS (Netherlands)

    Bouma, Esther M. C.; Riese, Harriette; Nolte, Ilja M.; Oosterom, Elvira; Verhulst, Frank C.; Ormel, Johan; Oldehinkel, Albertine J.

    Previously, sequence variation in the glucocorticoid (GR) and mineralocorticoid (MR) receptor genes (NR3C1 and NR3C2, respectively) have been found to be associated with physiological stress responses to social stress tests in small samples of adult men and oral contraceptives (OC) using women.

  8. Besting Testing Hysteria: Reasonable Preparation for Standardized Tests.

    Science.gov (United States)

    Field, Sherry L.

    2000-01-01

    Explores the content of the Iowa Test of Basic Skills (ITBS) and describes similarities between the ITBS and the National Council for the Social Studies (NCSS) standards. Addresses three NCSS standards and how each may be represented on a standardized test. Provides eight confidence-boosting principles. (CMK)

  9. Standard leach tests for nuclear waste materials

    International Nuclear Information System (INIS)

    Strachan, D.M.; Barnes, B.O.; Turcotte, R.P.

    1980-01-01

    Five leach tests were conducted to study time-dependent leaching of waste forms (glass). The first four tests include temperature as a variable and the use of three standard leachants. Three of the tests are static and two are dynamic (flow). This paper discusses the waste-form leach tests and presents some representative data. 4 figures

  10. Standards for educational and psychological testing

    CERN Document Server

    2014-01-01

    Developed jointly by the American Educational Research Association, American Psychological Association, and the National Council on Measurement in Education, Standards for Educational and Psychological Testing (Revised 2014) addresses professional and technical issues of test development and use in education, psychology, and employment. It includes changes in federal law and measurement trends affecting validity, testing individuals with disabilities or different linguistic backgrounds, and new types of tests, as well as new uses of existing tests.

  11. 76 FR 74078 - Standard Mail Market Test

    Science.gov (United States)

    2011-11-30

    ... POSTAL REGULATORY COMMISSION [Docket No. MT2011-3; Order No. 998] Standard Mail Market Test AGENCY... Service application for an exemption from the annual revenue limitation that applies to market tests of... limitation in any year during the test of an experimental market dominant product.\\1\\ Pursuant to 39 U.S.C...

  12. Neutron Sources for Standard-Based Testing

    Energy Technology Data Exchange (ETDEWEB)

    Radev, Radoslav [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); McLean, Thomas [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2014-11-10

    The DHS TC Standards and the consensus ANSI Standards use 252Cf as the neutron source for performance testing because its energy spectrum is similar to the 235U and 239Pu fission sources used in nuclear weapons. An emission rate of 20,000 ± 20% neutrons per second is used for testing of the radiological requirements both in the ANSI standards and the TCS. Determination of the accurate neutron emission rate of the test source is important for maintaining consistency and agreement between testing results obtained at different testing facilities. Several characteristics in the manufacture and the decay of the source need to be understood and accounted for in order to make an accurate measurement of the performance of the neutron detection instrument. Additionally, neutron response characteristics of the particular instrument need to be known and taken into account as well as neutron scattering in the testing environment.

  13. Standardized Definitions for Code Verification Test Problems

    Energy Technology Data Exchange (ETDEWEB)

    Doebling, Scott William [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-09-14

    This document contains standardized definitions for several commonly used code verification test problems. These definitions are intended to contain sufficient information to set up the test problem in a computational physics code. These definitions are intended to be used in conjunction with exact solutions to these problems generated using Exact- Pack, www.github.com/lanl/exactpack.

  14. Standard test method for instrumented impact testing of metallic materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This standard establishes the requirements for performing instrumented Charpy V-Notch (CVN) and instrumented Miniaturized Charpy V-Notch (MCVN) impact tests on metallic materials. This method, which is based on experience developed testing steels, provides further information (in addition to the total absorbed energy) on the fracture behavior of the tested materials. Minimum requirements are given for measurement and recording equipment such that similar sensitivity and comparable total absorbed energy measurements to those obtained in Test Methods E 23 and E 2248 are achieved. 1.2 The values stated in SI units are to be regarded as the standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  15. Standard test methods of tension testing of metallic foil

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1993-01-01

    1.1 These test methods cover the tension testing of metallic foil at room temperature in thicknesses less than 0.006 in. (0.150 mm). Note 1—Exception to these methods may be necessary in individual specifications or test methods for a particular material. 1.2 Units—The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  16. The skin prick test – European standards

    Directory of Open Access Journals (Sweden)

    Heinzerling Lucie

    2013-02-01

    Full Text Available Abstract Skin prick testing is an essential test procedure to confirm sensitization in IgE-mediated allergic disease in subjects with rhinoconjunctivitis, asthma, urticaria, anapylaxis, atopic eczema and food and drug allergy. This manuscript reviews the available evidence including Medline and Embase searches, abstracts of international allergy meetings and position papers from the world allergy literature. The recommended method of prick testing includes the appropriate use of specific allergen extracts, positive and negative controls, interpretation of the tests after 15 – 20 minutes of application, with a positive result defined as a wheal ≥3 mm diameter. A standard prick test panel for Europe for inhalants is proposed and includes hazel (Corylus avellana, alder (Alnus incana, birch (Betula alba, plane (Platanus vulgaris, cypress (Cupressus sempervirens, grass mix (Poa pratensis, Dactilis glomerata, Lolium perenne, Phleum pratense, Festuca pratensis, Helictotrichon pretense, Olive (Olea europaea, mugwort (Artemisia vulgaris, ragweed (Ambrosia artemisiifolia, Alternaria alternata (tenuis, Cladosporium herbarum, Aspergillus fumigatus, Parietaria, cat, dog, Dermatophagoides pteronyssinus, Dermatophagoides farinae, and cockroach (Blatella germanica. Standardization of the skin test procedures and standard panels for different geographic locations are encouraged worldwide to permit better comparisons for diagnostic, clinical and research purposes.

  17. Standardized Testing of Phasor Measurement Units

    Energy Technology Data Exchange (ETDEWEB)

    Martin, Kenneth E.; Faris, Anthony J.; Hauer, John F.

    2006-05-31

    This paper describes a set of tests used to determine Phasor Measurement Unit (PMU) measurement characteristics under steady state and dynamic conditions. The methodology is repeatable, comparable among test facilities, and can be performed at any facility with commonly available relay and standard test equipment. The methodology is based upon using test signals that are mathematically generated from a signal model and played into the PMU with precise GPS synchronization. Timing flags included with the test signal provide correlate the test signals and the PMU output. This allows accurate comparison of the phasor model with the value estimated by the PMU for accurate performance analysis. The timing flags also facilitate programmed plot and report generation.

  18. A standardized test battery for the study of synesthesia.

    Science.gov (United States)

    Eagleman, David M; Kagan, Arielle D; Nelson, Stephanie S; Sagaram, Deepak; Sarma, Anand K

    2007-01-15

    Synesthesia is an unusual condition in which stimulation of one modality evokes sensation or experience in another modality. Although discussed in the literature well over a century ago, synesthesia slipped out of the scientific spotlight for decades because of the difficulty in verifying and quantifying private perceptual experiences. In recent years, the study of synesthesia has enjoyed a renaissance due to the introduction of tests that demonstrate the reality of the condition, its automatic and involuntary nature, and its measurable perceptual consequences. However, while several research groups now study synesthesia, there is no single protocol for comparing, contrasting and pooling synesthetic subjects across these groups. There is no standard battery of tests, no quantifiable scoring system, and no standard phrasing of questions. Additionally, the tests that exist offer no means for data comparison. To remedy this deficit we have devised the Synesthesia Battery. This unified collection of tests is freely accessible online (http://www.synesthete.org). It consists of a questionnaire and several online software programs, and test results are immediately available for use by synesthetes and invited researchers. Performance on the tests is quantified with a standard scoring system. We introduce several novel tests here, and offer the software for running the tests. By presenting standardized procedures for testing and comparing subjects, this endeavor hopes to speed scientific progress in synesthesia research.

  19. Patch testing with Indian standard series

    Directory of Open Access Journals (Sweden)

    Narendra G

    2002-01-01

    Full Text Available Hundred patients (61 males, 39 females suspected to have allergic contact dermatitis were patch tested with Indian standard series (ISS. Forty four showed one or more positive reactions. The frequent sensitizers observed were nickel sulphate-12 (15%, potassium dichromate-11 (13.75%, cobalt chloride and colophony-7 (8.75% each, fragrance mix and thiuram mix-6 (7.5% each. The ISS differs from the European Standard Series by inclusion of propylene glycol, nitrofurazone, gentamicin, chlorocresol, PEG-400 and ethylenediamine chloride where assesquiterpene lactone mix and primin allergens are excluded.

  20. Standard Penetration Test and Relative Density

    Science.gov (United States)

    1971-02-01

    Se OPSeS Debido a que el agua subterranea granclemente influve la resistencia a suelo , se establecio una relacion empirica entre el nurmero de golpes...en la prueba normal de penetraci’n (Standard Penetration Test) de una arena bajo el nivel freatico y el correspond- iente numero en una arena seca (ie...sobre el nivel freatico) con la misma densidad relativa. Asimisnmo, porque se encontr6 que el nu.- mero de golpes depende no solo de la densidad

  1. Standardization of penetrating radiation testing system

    International Nuclear Information System (INIS)

    Wiley, P.A.; Aronson, H.L.

    1979-01-01

    Standardization is provided to control system gain of a penetrating radiation testing system by periodically inspecting a reference object in the same manner as the product samples so as to generate a stabilization signal which is compared to a reference signal. The difference, if any, between the stabilization signal and the reference signal is integrated and the integrated signal is used to correct the gain of the system

  2. Standardization of Tests for Advanced Composites

    OpenAIRE

    石川, 隆司; ISHIKAWA, Takashi; 野口, 義男; NOGUCHI, Yoshio; 濱口, 泰正; HAMAGUCHI, Yasumasa

    2003-01-01

    Advanced composites are essentially the only feasible materials for the construction of newly developed aerospace vehicle. However, the path to be followed for the validation, evaluation and certification of composite aircraft structures is quite different from that of traditional metallic aircraft structures, and the importance of a composites database is now well recognized. A key issue in constructing a fully descriptive composites database is to establish standard composite test methods, ...

  3. Standard test method for dynamic tear testing of metallic materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1983-01-01

    1.1 This test method covers the dynamic tear (DT) test using specimens that are 3/16 in. to 5/8 in. (5 mm to 16 mm) inclusive in thickness. 1.2 This test method is applicable to materials with a minimum thickness of 3/16 in. (5 mm). 1.3 The pressed-knife procedure described for sharpening the notch tip generally limits this test method to materials with a hardness level less than 36 HRC. Note 1—The designation 36 HRC is a Rockwell hardness number of 36 on Rockwell C scale as defined in Test Methods E 18. 1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  4. Experimentally testing the standard cosmological model

    Energy Technology Data Exchange (ETDEWEB)

    Schramm, D.N. (Chicago Univ., IL (USA) Fermi National Accelerator Lab., Batavia, IL (USA))

    1990-11-01

    The standard model of cosmology, the big bang, is now being tested and confirmed to remarkable accuracy. Recent high precision measurements relate to the microwave background; and big bang nucleosynthesis. This paper focuses on the latter since that relates more directly to high energy experiments. In particular, the recent LEP (and SLC) results on the number of neutrinos are discussed as a positive laboratory test of the standard cosmology scenario. Discussion is presented on the improved light element observational data as well as the improved neutron lifetime data. alternate nucleosynthesis scenarios of decaying matter or of quark-hadron induced inhomogeneities are discussed. It is shown that when these scenarios are made to fit the observed abundances accurately, the resulting conclusions on the baryonic density relative to the critical density, {Omega}{sub b}, remain approximately the same as in the standard homogeneous case, thus, adding to the robustness of the standard model conclusion that {Omega}{sub b} {approximately} 0.06. This latter point is the deriving force behind the need for non-baryonic dark matter (assuming {Omega}{sub total} = 1) and the need for dark baryonic matter, since {Omega}{sub visible} < {Omega}{sub b}. Recent accelerator constraints on non-baryonic matter are discussed, showing that any massive cold dark matter candidate must now have a mass M{sub x} {approx gt} 20 GeV and an interaction weaker than the Z{sup 0} coupling to a neutrino. It is also noted that recent hints regarding the solar neutrino experiments coupled with the see-saw model for {nu}-masses may imply that the {nu}{sub {tau}} is a good hot dark matter candidate. 73 refs., 5 figs.

  5. Laboratory tests for single-event effects

    International Nuclear Information System (INIS)

    Buchner, S.; McMorrow, D.; Melinger, J.; Campbell, A.B.

    1996-01-01

    Integrated circuits are currently tested at accelerators for their susceptibility to single-event effects (SEE's). However, because of the cost and limited accessibility associated with accelerator testing, there is considerable interest in developing alternate testing methods. Two laboratory techniques for measuring SEE, one involving a pulsed laser and the other 252 Cf, are described in detail in this paper. The pulsed laser provides information on the spatial and temporal dependence of SEE, information that has proven invaluable in understanding and mitigating SEE in spite of the differences in the physical mechanisms responsible for SEE induced by light and by ions. Considerable effort has been expended on developing 252 Cf as a laboratory test for SEE, but the technique has not found wide use because it is severely limited by the low energy and short range of the emitted ions that are unable to reach junctions either covered with dielectric layers or deep below the surface. In fact, there are documented cases where single-event latchup (SEL) testing with 252 Cf gave significantly different results from accelerator testing. A detailed comparison of laboratory and accelerator SEE data is presented in this review in order to establish the limits of each technique

  6. Consistency test of the standard model

    International Nuclear Information System (INIS)

    Pawlowski, M.; Raczka, R.

    1997-01-01

    If the 'Higgs mass' is not the physical mass of a real particle but rather an effective ultraviolet cutoff then a process energy dependence of this cutoff must be admitted. Precision data from at least two energy scale experimental points are necessary to test this hypothesis. The first set of precision data is provided by the Z-boson peak experiments. We argue that the second set can be given by 10-20 GeV e + e - colliders. We pay attention to the special role of tau polarization experiments that can be sensitive to the 'Higgs mass' for a sample of ∼ 10 8 produced tau pairs. We argue that such a study may be regarded as a negative selfconsistency test of the Standard Model and of most of its extensions

  7. Multipurpose laboratory test system applying CAMAC standards

    Energy Technology Data Exchange (ETDEWEB)

    Bowers, J.L.

    1976-11-01

    A flexible electronic product test and evaluation system is proposed. A system study was performed to determine how increasingly complex telemetry systems could be effectively evaluated during development and preproduction and after first production units were built. A primary requirement was that this system remain flexible with respect to configuration and mission and that it be easily maintainable. In addition, the system must be upgraded easily as old product requirements and definitions are replaced by new designs. As a result of this study it is concluded that this project would involve the expenditure of considerable funds and manpower at the beginning of the project and that the cost effectiveness of the system would be dependent upon its utilization and management. This study also demonstrates how the use of computer interface hardware standards (IEEE 583) can minimize requirements for expensive specially designed test equipment for each application.

  8. NEXT Single String Integration Test Results

    Science.gov (United States)

    Soulas, George C.; Patterson, Michael J.; Pinero, Luis; Herman, Daniel A.; Snyder, Steven John

    2010-01-01

    As a critical part of NASA's Evolutionary Xenon Thruster (NEXT) test validation process, a single string integration test was performed on the NEXT ion propulsion system. The objectives of this test were to verify that an integrated system of major NEXT ion propulsion system elements meets project requirements, to demonstrate that the integrated system is functional across the entire power processor and xenon propellant management system input ranges, and to demonstrate to potential users that the NEXT propulsion system is ready for transition to flight. Propulsion system elements included in this system integration test were an engineering model ion thruster, an engineering model propellant management system, an engineering model power processor unit, and a digital control interface unit simulator that acted as a test console. Project requirements that were verified during this system integration test included individual element requirements ; integrated system requirements, and fault handling. This paper will present the results of these tests, which include: integrated ion propulsion system demonstrations of performance, functionality and fault handling; a thruster re-performance acceptance test to establish baseline performance: a risk-reduction PMS-thruster integration test: and propellant management system calibration checks.

  9. Framework for a Comparative Accelerated Testing Standard for PV Modules: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Kurtz, S.; Wohlgemuth, J.; Yamamichi, M.; Sample, T.; Miller, D.; Meakin, D.; Monokroussos, C.; TamizhMani, M.; Kempe, M.; Jordan, D.; Bosco, N.; Hacke, P.; Bermudez, V.; Kondo, M.

    2013-08-01

    As the photovoltaic industry has grown, the interest in comparative accelerated testing has also grown. Private test labs offer testing services that apply greater stress than the standard qualification tests as tools for differentiating products and for gaining increased confidence in long-term PV investments. While the value of a single international standard for comparative accelerated testing is widely acknowledged, the development of a consensus is difficult. This paper strives to identify a technical basis for a comparative standard.

  10. Standard-E hydrogen monitoring system shop acceptance test report

    International Nuclear Information System (INIS)

    Schneider, T.C.

    1997-01-01

    The purpose of this report is to document that the Standard-E Hydrogen Monitoring Systems (SHMS-E), fabricated by Mid-Columbia Engineering (MCE) for installation on the Waste Tank Farms in the Hanford 200 Areas, are constructed as intended by the design. The ATP performance will verify proper system fabrication

  11. Standard-E hydrogen monitoring system shop acceptance test procedure

    Energy Technology Data Exchange (ETDEWEB)

    Schneider, T.C.

    1997-10-02

    The purpose of this report is to document that the Standard-E Hydrogen Monitoring Systems (SHMS-E), fabricated by Mid-Columbia Engineering (MCE) for installation on the Waste Tank Farms in the Hanford 200 Areas, are constructed as intended by the design. The ATP performance will verify proper system fabrication.

  12. Standard practice for instrumented indentation testing

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2007-01-01

    1.1 This practice defines the basic steps of Instrumented Indentation Testing (IIT) and establishes the requirements, accuracies, and capabilities needed by an instrument to successfully perform the test and produce the data that can be used for the determination of indentation hardness and other material characteristics. IIT is a mechanical test that measures the response of a material to the imposed stress and strain of a shaped indenter by forcing the indenter into a material and monitoring the force on, and displacement of, the indenter as a function of time during the full loading-unloading test cycle. 1.2 The operational features of an IIT instrument, as well as requirements for Instrument Verification Annex A1), Standardized Reference Blocks (Annex A2) and Indenter Requirements (Annex A3) are defined. This practice is not intended to be a complete purchase specification for an IIT instrument. 1.3 With the exception of the non-mandatory Appendix X4, this practice does not define the analysis necessary...

  13. 49 CFR 232.309 - Equipment and devices used to perform single car air brake tests.

    Science.gov (United States)

    2010-10-01

    ... (Continued) FEDERAL RAILROAD ADMINISTRATION, DEPARTMENT OF TRANSPORTATION BRAKE SYSTEM SAFETY STANDARDS FOR... Testing Requirements § 232.309 Equipment and devices used to perform single car air brake tests. (a) Equipment and devices used to perform single car air brake tests shall be tested for correct operation at...

  14. 42 CFR 493.1423 - Standard; Testing personnel qualifications.

    Science.gov (United States)

    2010-10-01

    ..., or bachelor's degree in a chemical, physical, biological or clinical laboratory science, or medical... HUMAN SERVICES (CONTINUED) STANDARDS AND CERTIFICATION LABORATORY REQUIREMENTS Personnel for Nonwaived Testing Laboratories Performing Moderate Complexity Testing § 493.1423 Standard; Testing personnel...

  15. Experimental tests of the standard model

    International Nuclear Information System (INIS)

    Nodulman, L.

    1998-01-01

    The title implies an impossibly broad field, as the Standard Model includes the fermion matter states, as well as the forces and fields of SU(3) x SU(2) x U(1). For practical purposes, I will confine myself to electroweak unification, as discussed in the lectures of M. Herrero. Quarks and mixing were discussed in the lectures of R. Aleksan, and leptons and mixing were discussed in the lectures of K. Nakamura. I will essentially assume universality, that is flavor independence, rather than discussing tests of it. I will not pursue tests of QED beyond noting the consistency and precision of measurements of α EM in various processes including the Lamb shift, the anomalous magnetic moment (g-2) of the electron, and the quantum Hall effect. The fantastic precision and agreement of these predictions and measurements is something that convinces people that there may be something to this science enterprise. Also impressive is the success of the ''Universal Fermi Interaction'' description of beta decay processes, or in more modern parlance, weak charged current interactions. With one coupling constant G F , most precisely determined in muon decay, a huge number of nuclear instabilities are described. The slightly slow rate for neutron beta decay was one of the initial pieces of evidence for Cabbibo mixing, now generalized so that all charged current decays of any flavor are covered

  16. Experimental tests of the standard model.

    Energy Technology Data Exchange (ETDEWEB)

    Nodulman, L.

    1998-11-11

    The title implies an impossibly broad field, as the Standard Model includes the fermion matter states, as well as the forces and fields of SU(3) x SU(2) x U(1). For practical purposes, I will confine myself to electroweak unification, as discussed in the lectures of M. Herrero. Quarks and mixing were discussed in the lectures of R. Aleksan, and leptons and mixing were discussed in the lectures of K. Nakamura. I will essentially assume universality, that is flavor independence, rather than discussing tests of it. I will not pursue tests of QED beyond noting the consistency and precision of measurements of {alpha}{sub EM} in various processes including the Lamb shift, the anomalous magnetic moment (g-2) of the electron, and the quantum Hall effect. The fantastic precision and agreement of these predictions and measurements is something that convinces people that there may be something to this science enterprise. Also impressive is the success of the ''Universal Fermi Interaction'' description of beta decay processes, or in more modern parlance, weak charged current interactions. With one coupling constant G{sub F}, most precisely determined in muon decay, a huge number of nuclear instabilities are described. The slightly slow rate for neutron beta decay was one of the initial pieces of evidence for Cabbibo mixing, now generalized so that all charged current decays of any flavor are covered.

  17. Standard test method for conducting erosion tests by solid particle impingement using gas jets

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2007-01-01

    1.1 This test method covers the determination of material loss by gas-entrained solid particle impingement erosion with jetnozzle type erosion equipment. This test method may be used in the laboratory to measure the solid particle erosion of different materials and has been used as a screening test for ranking solid particle erosion rates of materials in simulated service environments (1,2 ). Actual erosion service involves particle sizes, velocities, attack angles, environments, and so forth, that will vary over a wide range (3-5). Hence, any single laboratory test may not be sufficient to evaluate expected service performance. This test method describes one well characterized procedure for solid particle impingement erosion measurement for which interlaboratory test results are available. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determi...

  18. Characterization of Single-Photon Avalanche Diodes in Standard 140-nm SOI CMOS Technology

    NARCIS (Netherlands)

    Lee, M.J.; Sun, P.; Charbon, E.

    2015-01-01

    We report on the characterization of single-photon avalanche diodes (SPADs) fabricated in standard 140-nm silicon on insulator (SOI) complementary metal-oxide-semiconductor (CMOS) technology. As a methodology for SPAD optimization, a test structure array, called SPAD farm, was realized with several

  19. Improving Single Event Effects Testing Through Software

    Science.gov (United States)

    Banker, M. W.

    2011-01-01

    Radiation encountered in space environments can be damaging to microelectronics and potentially cause spacecraft failure. Single event effects (SEE) are a type of radiation effect that occur when an ion strikes a device. Single event gate rupture (SEGR) is a type of SEE that can cause failure in power transistors. Unlike other SEE rates in which a constant linear energy transfer (LET) can be used, SEGR rates sometimes require a non-uniform LET to be used to be accurate. A recent analysis shows that SEGR rates are most easily calculated when the environment is described as a stopping rate per unit volume for each ion species. Stopping rates in silicon for pertinent ions were calculated using the Stopping and Range of Ions in Matter (SRIM) software and CREME-MC software. A reference table was generated and can be used by others to calculate SEGR rates for a candidate device. Additionally, lasers can be used to simulate SEEs, providing more control and information at lower cost than heavy ion testing. The electron/hole pair generation rate from a laser pulse in a semiconductor can be related to the LET of an ion. MATLAB was used to generate a plot to easily make this comparison.

  20. IEC 61850 Industrial Communication Standards under Test

    CERN Document Server

    Tilaro, F M; Gonzalez-Berges, M

    2014-01-01

    IEC-61850, as part of the International Electrotechnical Commission's (IEC) Technical Committee 57 (TC57), defines an international and standardized methodology to design electric power automation substations.

  1. Testing Procedure for the Single Fiber Fragmentation Test

    DEFF Research Database (Denmark)

    Feih, Stefanie; Wonsyld, Karen; Minzari, Daniel

    , specimens with one E-glass fiber placed inside an epoxy or polyester matrix were used. Elongating the specimens with a mini tensile tester, which was placed under a microscope, leads to fiber fragmentations. Different bonding strengths between fiber and matrix result in differences in the critical fracture......This report describes the details of the single fiber fragmentation test as conducted at the materials research department (AFM) at Risø. The equipment and specimen manufacture is described in detail. Furthermore, examples of results interpretation are given. For the experiments in this report...... length for the fiber and fracture characteristics....

  2. Instrument Rating Practical Test Standards for Airplane, Helicopter, Airship

    Science.gov (United States)

    1994-10-01

    The Instrument Rating Practical Test Standards (PTS) book has : been published by the Federal Aviation Administration (FAA) to : establish the standards for the instrument rating practical test for : airplanes, helicopters, and airships. FAA inspecto...

  3. Interpreting Results from the Standardized UXO Test Sites

    National Research Council Canada - National Science Library

    May, Michael; Tuley, Michael

    2007-01-01

    ...) and the Environmental Security Technology Certification Program (ESCTP) to complete a detailed analysis of the results of testing carried out at the Standardized Unexploded Ordnance (UXO) Test Sites...

  4. Standardized Testing and the Construction of Governable Persons

    Science.gov (United States)

    Graham, Cameron; Neu, Dean

    2004-01-01

    While debates over standardized testing are ubiquitous, there has been relatively little consideration of how today's standardized testing practices have arisen. The current study provides a chronology of standardized testing within Alberta, Canada. Starting from prior work by Foucault and others on "governmentality", we propose that the…

  5. Standard Guide for Testing Polymer Matrix Composite Materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2011-01-01

    1.1 This guide summarizes the application of ASTM standard test methods (and other supporting standards) to continuous-fiber reinforced polymer matrix composite materials. The most commonly used or most applicable ASTM standards are included, emphasizing use of standards of Committee D30 on Composite Materials. 1.2 This guide does not cover all possible standards that could apply to polymer matrix composites and restricts discussion to the documented scope. Commonly used but non-standard industry extensions of test method scopes, such as application of static test methods to fatigue testing, are not discussed. A more complete summary of general composite testing standards, including non-ASTM test methods, is included in the Composite Materials Handbook (MIL-HDBK-17). Additional specific recommendations for testing textile (fabric, braided) composites are contained in Guide D6856. 1.3 This guide does not specify a system of measurement; the systems specified within each of the referenced standards shall appl...

  6. Standard Testing Methods for Satellite Communication Systems

    OpenAIRE

    Stoner, Jerry

    2005-01-01

    University space programs continue to push the envelope of small satellite technology. Because budgets are often limited, and equipment costs can often be prohibitive to even well-established space programs, it becomes necessary to maximize the benefit/cost ratio of testing methods. Expensive testing is often not an option, nor is it realistic. Traditional methods such as anechoic chambers or antenna test ranges are not options, and testing the craft on the ground is not practical. Because of...

  7. Standard test methods for rockwell hardness of metallic materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 These test methods cover the determination of the Rockwell hardness and the Rockwell superficial hardness of metallic materials by the Rockwell indentation hardness principle. This standard provides the requirements for Rockwell hardness machines and the procedures for performing Rockwell hardness tests. 1.2 This standard includes additional requirements in annexes: Verification of Rockwell Hardness Testing Machines Annex A1 Rockwell Hardness Standardizing Machines Annex A2 Standardization of Rockwell Indenters Annex A3 Standardization of Rockwell Hardness Test Blocks Annex A4 Guidelines for Determining the Minimum Thickness of a Test Piece Annex A5 Hardness Value Corrections When Testing on Convex Cylindrical Surfaces Annex A6 1.3 This standard includes nonmandatory information in appendixes which relates to the Rockwell hardness test. List of ASTM Standards Giving Hardness Values Corresponding to Tensile Strength Appendix X1 Examples of Procedures for Determining Rockwell Hardness Uncertainty Appendix X...

  8. Standard test methods for rockwell hardness of metallic materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2011-01-01

    1.1 These test methods cover the determination of the Rockwell hardness and the Rockwell superficial hardness of metallic materials by the Rockwell indentation hardness principle. This standard provides the requirements for Rockwell hardness machines and the procedures for performing Rockwell hardness tests. 1.2 This standard includes additional requirements in annexes: Verification of Rockwell Hardness Testing Machines Annex A1 Rockwell Hardness Standardizing Machines Annex A2 Standardization of Rockwell Indenters Annex A3 Standardization of Rockwell Hardness Test Blocks Annex A4 Guidelines for Determining the Minimum Thickness of a Test Piece Annex A5 Hardness Value Corrections When Testing on Convex Cylindrical Surfaces Annex A6 1.3 This standard includes nonmandatory information in appendixes which relates to the Rockwell hardness test. List of ASTM Standards Giving Hardness Values Corresponding to Tensile Strength Appendix X1 Examples of Procedures for Determining Rockwell Hardness Uncertainty Appendix X...

  9. Standard test for nuclear waste materials

    International Nuclear Information System (INIS)

    Nelson, R.D.; Mendel, J.E.; Turcotte, R.P.

    1981-01-01

    The function of the Materials Characterization Center (MCC) is to provide the standardized materials data base and supporting documentation to help ensure safe disposal of nuclear waste. The methods and data are being published in a Nuclear Waste Materials Handbook DOE/TIC 11400. (DG)

  10. Test System for Standard ALICE DCS Components

    CERN Document Server

    AUTHOR|(CDS)2160773

    2016-01-01

    Currently, the ALICE DCS project is supervising equipment installed in the ALICE experiment site at CERN. Hence, the aim of this project was to provide a test bench in the DCS lab, where a real equipment and software tools will be deployed. Using this test bench, test procedures which exercise the devices under the test in a configurable way and provide logging and trending of the acquired data were implemented. The setup was devised using the ALICE software framework and Siemens SCADA system WINCC OA, providing the same functionality as the systems installed in ALICE, and will be used for the commissioning of the new software and hardware, burn-in tests of new modules and log-term stability tests of ALICE hardware.

  11. 49 CFR 238.311 - Single car test.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Single car test. 238.311 Section 238.311... Requirements for Tier I Passenger Equipment § 238.311 Single car test. (a) Except for self-propelled passenger cars, single car tests of all passenger cars and all unpowered vehicles used in passenger trains shall...

  12. The skin prick test - European standards

    NARCIS (Netherlands)

    Heinzerling, Lucie; Mari, Adriano; Bergmann, Karl-Christian; Bresciani, Megon; Burbach, Guido; Darsow, Ulf; Durham, Stephen; Fokkens, Wytske; Gjomarkaj, Mark; Haahtela, Tari; Bom, Ana Todo; Wöhrl, Stefan; Maibach, Howard; Lockey, Richard

    2013-01-01

    Skin prick testing is an essential test procedure to confirm sensitization in IgE-mediated allergic disease in subjects with rhinoconjunctivitis, asthma, urticaria, anapylaxis, atopic eczema and food and drug allergy. This manuscript reviews the available evidence including Medline and Embase

  13. 42 CFR 493.1281 - Standard: Comparison of test results.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 5 2010-10-01 2010-10-01 false Standard: Comparison of test results. 493.1281 Section 493.1281 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) STANDARDS AND CERTIFICATION LABORATORY REQUIREMENTS Quality System for Nonwaived Testing Analytic Systems § 493.1281 Standard:...

  14. Cancer Screening: How Do Screening Tests Become Standard Tests?

    Science.gov (United States)

    ... Colonoscopy for colorectal cancer . Mammograms for breast cancer . Pap tests (Pap smears) for cervical cancer . Different types of ... follow a group of women who have regular Pap tests, and divide them into those who test positive ...

  15. SEDIMENT TOXICITY ASSESSMENT: COMPARISON OF STANDARD AND NEW TESTING DESIGNS

    Science.gov (United States)

    Standard methods of sediment toxicity testing are fairly well accepted; however, as with all else, evolution of these methods is inevitable. We compared a standard ASTM 10-day amphipod toxicity testing method with smaller, 48- and 96-h test methods using very toxic and reference ...

  16. Standard guide for fretting fatigue testing

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This guide defines terminology and covers general requirements for conducting fretting fatigue tests and reporting the results. It describes the general types of fretting fatigue tests and provides some suggestions on developing and conducting fretting fatigue test programs. 1.2 Fretting fatigue tests are designed to determine the effects of mechanical and environmental parameters on the fretting fatigue behavior of metallic materials. This guide is not intended to establish preference of one apparatus or specimen design over others, but will establish guidelines for adherence in the design, calibration, and use of fretting fatigue apparatus and recommend the means to collect, record, and reporting of the data. 1.3 The number of cycles to form a fretting fatigue crack is dependent on both the material of the fatigue specimen and fretting pad, the geometry of contact between the two, and the method by which the loading and displacement are imposed. Similar to wear behavior of materials, it is important t...

  17. Towards a standardization of biomethane potential tests

    DEFF Research Database (Denmark)

    Holliger, C.; Alves, M.; Andrade, D.

    2016-01-01

    Production of biogas fromdifferent organic materials is a most interesting source of renewable energy. The biomethane potential (BMP) of these materials has to be determined to get insight in design parameters for anaerobic digesters. Although several norms and guidelines for BMP tests exist, int...

  18. HISTORY AND EVOLUTION OF STANDARDIZED TESTING – A LITERATURE REVIEW

    OpenAIRE

    Dr. Syeda Rakhshanda Kaukab; Syeda Mehrunnisa

    2017-01-01

    This paper has been written with the intent of providing the history and evolution of the modern standardized testing while also highlighting the importance, pros and cons of standardized testing. In Pakistan, recently the higher education institution has established institute for development and implementation of standardized testing for admissions to the universities. It is for the first time that this is being introduced. Therefore, it appears in order that first the global development and...

  19. Standard test method for creep-fatigue testing

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This test method covers the determination of mechanical properties pertaining to creep-fatigue deformation or crack formation in nominally homogeneous materials, or both by the use of test specimens subjected to uniaxial forces under isothermal conditions. It concerns fatigue testing at strain rates or with cycles involving sufficiently long hold times to be responsible for the cyclic deformation response and cycles to crack formation to be affected by creep (and oxidation). It is intended as a test method for fatigue testing performed in support of such activities as materials research and development, mechanical design, process and quality control, product performance, and failure analysis. The cyclic conditions responsible for creep-fatigue deformation and cracking vary with material and with temperature for a given material. 1.2 The use of this test method is limited to specimens and does not cover testing of full-scale components, structures, or consumer products. 1.3 This test method is primarily ...

  20. Historical Evolution of NASA Standard Materials Testing with Hypergolic Propellants and Ammonia (NASA Standard 6001 Test 15)

    Science.gov (United States)

    Greene, Benjamin; McClure, Mark B.

    2012-01-01

    The NASA Johnson Space Center White Sands Test Facility (WSTF) has performed testing of hazardous and reactive aerospace fluids, including hypergolic propellants, with materials since the 1960s with the Apollo program. Amongst other test activities, Test 15 is a NASA standard test for evaluating the reactivity of materials with selected aerospace fluids, in particular hydrazine, monomethylhydrazine, uns-dimethylhydrazine, Aerozine 50, dinitrogen tetroxide oxidizers, and ammonia. This manuscript provides an overview of the history of Test 15 over a timeline ranging from prior to its development and first implementation as a NASA standard test in 1974 to its current refinement. Precursor documents to NASA standard tests, as they are currently known, are reviewed. A related supplementary test, international standardization, and enhancements to Test 15 are also discussed. Because WSTF was instrumental in the development and implementation of Test 15, WSTF experience and practices are referred to in this manuscript.

  1. Standard Test Method for Testing Nonmetallic Seal Materials by Immersion in a Simulated Geothermal Test Fluid

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1985-01-01

    1.1 This test method covers a procedure for a laboratory test for performing an initial evaluation (screening) of nonmetallic seal materials by immersion in a simulated geothermal test fluid. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific precautionary statements, see Section 6 and 11.7.

  2. Testing Conformance to Standards: Notes on the OGC CITE Initiative

    Science.gov (United States)

    Bigagli, Lorenzo; Vitale, Fabrizio

    2010-05-01

    In this work, we report on the issues and lessons learnt from our recent experience on assessing service compliance to OGC geospatial standards. Official conformity is warranted by the OGC Compliance & Interoperability Testing & Evaluation (CITE) initiative, through a centrally managed repository of tests, typically developed via initiatives funded by external sponsors. In particular, we have been involved in the ESA-led Heterogeneous Missions Accessibility Testbed (HMA-T) project. HMA-T objectives included the definition of specifications (and related compliance tests) for Earth Observation (EO) Product discovery and access. Our activities have focused on the EO and Catalogue of ISO Metadata (CIM) Extension Packages (EPs) of the ebRIM Application Profile (AP) of the Catalogue Service for the Web (CSW) OGC standard. Our main contributions have regarded the definition of Abstract Test Suites (ATS's) for the above specifications, as well as the development of Reference Implementations (RIs) and concrete Executable Test Suites (ETS's). According to the state-of-the-art, we have implemented the ETS's in Compliance Test Language (CTL), an OGC standard dialect of XML, and deployed the scripts onto the open-source Test Evaluation And Measurement (TEAM) Engine, the official OGC compliance test platform. A significant challenge was to accommodate legacy services, that can not support data publishing. Hence, we could not assume the presence of control test data, necessary for exhaustive assessment. To cope with this, we have proposed and experimented tests for assessing the internal coherence of a target service instance. Another issue was to assess the overall behavior of a target service instance. Although quite obvious, this requirement proved to be hard (if unviable) to implement, since the design of the OGC catalogue specification is multi-layered (i.e. comprised of EP, AP, binding and core functionalities) and, according to the current OGC rationale, ATS/ETS at each

  3. 10-bit rapid single flux quantum digital-to-analog converter for ac voltage standard

    International Nuclear Information System (INIS)

    Maezawa, M; Hirayama, F

    2008-01-01

    Digital-to-analog (D/A) converters based on rapid single flux quantum (RSFQ) technology are under development for ac voltage standard applications. We present design and test results on a prototype 10-bit version integrated on a single chip. The 10-bit chip includes over 6000 Josephson junctions and consumes a bias current exceeding 1 A. To reduce the effects of the high bias current on circuit operation, a custom design method was employed in part and large circuit blocks were divided into smaller ones. The 10-bit chips were fabricated and tested at low speed. The test results suggested that our design approach could manage large bias currents on the order of 1 A per chip

  4. DOE standard: Quality assurance inspection and testing of HEPA filters

    International Nuclear Information System (INIS)

    1999-02-01

    This standard establishes essential elements for the quality assurance inspection and testing of HEPA filters by US Department of Energy (DOE)-accepted Filter Test Facilities (FTF). The standard specifies HEPA filter quality assurance inspection and testing practices established in DOE-STD-3022-98, DOE HEPA Filter Test Program, and provides a basis for the preparation of written operating procedures for primary FTF functions

  5. Single specimen fracture toughness determination procedure using instrumented impact test

    International Nuclear Information System (INIS)

    Rintamaa, R.

    1993-04-01

    In the study a new single specimen test method and testing facility for evaluating dynamic fracture toughness has been developed. The method is based on the application of a new pendulum type instrumented impact tester equipped with and optical crack mouth opening displacement (COD) extensometer. The fracture toughness measurement technique uses the Double Displacement Ratio (DDR) method, which is based on the assumption that the specimen is deformed as two rigid arms that rotate around an apparent centre of rotation. This apparent moves as the crack grows, and the ratio of COD versus specimen displacement changes. As a consequence the onset ductile crack initiation can be detected on the load-displacement curve. Thus, an energy-based fracture toughness can be calculated. In addition the testing apparatus can use specimens with the Double ligament size as compared with the standard Charpy specimen which makes the impact testing more appropriate from the fracture mechanics point of view. The novel features of the testing facility and the feasibility of the new DDR method has been verified by performing an extensive experimental and analytical study. (99 refs., 91 figs., 27 tabs.)

  6. Evaluation of a single leg stance balance test in children.

    Science.gov (United States)

    Zumbrunn, Thomas; MacWilliams, Bruce A; Johnson, Barbara A

    2011-06-01

    Balance is a major determinate of gait. In high functioning individuals without significant vestibular or vision impairments, a ceiling effect may be present when using a double limb support protocol to assess balance function. For these populations, a single leg stance protocol may be more suitable. 47 typically developing (TD) subjects and 10 patients with CEV performed a single leg stance test on a force plate. The center of pressure (COP) was determined and several COP derived variables were calculated. Included measurements were: standard deviation, maximum excursion, area, average radial displacement, path velocity and frequency of the COP. Directional components of suitable variables were used to analyze anterior/posterior and medial/lateral contributions. Correlations with age of TD subjects indicated that all balance variables except frequency were significantly correlated. Most parameters were highly inter-correlated. Age adjusted COP balance variables also correlated to the Bruininks-Oseretsky balance subtest. Highest correlations were determined by the maximum excursion and velocity of the COP in the anterior/posterior direction. Statistical comparisons between the CEV group and a 4-6 TD group indicated significant differences between groups for most COP balance parameters. These results indicated that a single limb balance assessment may be a useful assessment for determining balance impairments in higher functioning children with orthopedic impairments. Copyright © 2011 Elsevier B.V. All rights reserved.

  7. Issues in Standardizing Psychometric Tests for Children Who Are Blind.

    Science.gov (United States)

    Hull, T.; Mason, H.

    1993-01-01

    This article discusses issues and difficulties encountered in efforts at the University of Birmingham (England) to standardize a new psychometric assessment tool, a tactile speed-of-information-processing test for children with blindness. The problem of defining the population on which the test is standardized is seen as particularly difficult.…

  8. Gold Standard Testing of Motion Based Tracking Systems

    Science.gov (United States)

    2017-03-15

    AFRL-RH-WP-TR-2017-0032 GOLD STANDARD TESTING OF MOTION BASED TRACKING SYSTEMS Joshua Hagen Human Signatures Branch Human-Centered ISR Division...DD-MM-YY) 2. REPORT TYPE 3. DATES COVERED (From - To) 15 03 17 Interim Report June 2016 – March 2017 4. TITLE AND SUBTITLE Gold Standard Testing of...systems against a ‘ Gold Standard ’ on-field measurement system for human physiological performance monitoring. Data shows that the accuracy of the

  9. Hearing Aid–Related Standards and Test Systems

    Science.gov (United States)

    Ravn, Gert; Preves, David

    2015-01-01

    Many documents describe standardized methods and standard equipment requirements in the field of audiology and hearing aids. These standards will ensure a uniform level and a high quality of both the methods and equipment used in audiological work. The standards create the basis for measuring performance in a reproducible manner and independent from how and when and by whom parameters have been measured. This article explains, and focuses on, relevant acoustic and electromagnetic compatibility parameters and describes several test systems available. PMID:27516709

  10. Standard test methods for bend testing of material for ductility

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 These test methods cover bend testing for ductility of materials. Included in the procedures are four conditions of constraint on the bent portion of the specimen; a guided-bend test using a mandrel or plunger of defined dimensions to force the mid-length of the specimen between two supports separated by a defined space; a semi-guided bend test in which the specimen is bent, while in contact with a mandrel, through a specified angle or to a specified inside radius (r) of curvature, measured while under the bending force; a free-bend test in which the ends of the specimen are brought toward each other, but in which no transverse force is applied to the bend itself and there is no contact of the concave inside surface of the bend with other material; a bend and flatten test, in which a transverse force is applied to the bend such that the legs make contact with each other over the length of the specimen. 1.2 After bending, the convex surface of the bend is examined for evidence of a crack or surface irregu...

  11. Single Event Testing on Complex Devices: Test Like You Fly versus Test-Specific Design Structures

    Science.gov (United States)

    Berg, Melanie; LaBel, Kenneth A.

    2014-01-01

    We present a framework for evaluating complex digital systems targeted for harsh radiation environments such as space. Focus is limited to analyzing the single event upset (SEU) susceptibility of designs implemented inside Field Programmable Gate Array (FPGA) devices. Tradeoffs are provided between application-specific versus test-specific test structures.

  12. Standard test method for creep-fatigue crack growth testing

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This test method covers the determination of creep-fatigue crack growth properties of nominally homogeneous materials by use of pre-cracked compact type, C(T), test specimens subjected to uniaxial cyclic forces. It concerns fatigue cycling with sufficiently long loading/unloading rates or hold-times, or both, to cause creep deformation at the crack tip and the creep deformation be responsible for enhanced crack growth per loading cycle. It is intended as a guide for creep-fatigue testing performed in support of such activities as materials research and development, mechanical design, process and quality control, product performance, and failure analysis. Therefore, this method requires testing of at least two specimens that yield overlapping crack growth rate data. The cyclic conditions responsible for creep-fatigue deformation and enhanced crack growth vary with material and with temperature for a given material. The effects of environment such as time-dependent oxidation in enhancing the crack growth ra...

  13. Standard test method for liquid impingement erosion using rotating apparatus

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This test method covers tests in which solid specimens are eroded or otherwise damaged by repeated discrete impacts of liquid drops or jets. Among the collateral forms of damage considered are degradation of optical properties of window materials, and penetration, separation, or destruction of coatings. The objective of the tests may be to determine the resistance to erosion or other damage of the materials or coatings under test, or to investigate the damage mechanisms and the effect of test variables. Because of the specialized nature of these tests and the desire in many cases to simulate to some degree the expected service environment, the specification of a standard apparatus is not deemed practicable. This test method gives guidance in setting up a test, and specifies test and analysis procedures and reporting requirements that can be followed even with quite widely differing materials, test facilities, and test conditions. It also provides a standardized scale of erosion resistance numbers applicab...

  14. Standard guide for conducting exfoliation corrosion tests in aluminum alloys

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1992-01-01

    1.1 This guide differs from the usual ASTM standard in that it does not address a specific test. Rather, it is an introductory guide for new users of other standard exfoliation test methods, (see Terminology G 15 for definition of exfoliation). 1.2 This guide covers aspects of specimen preparation, exposure, inspection, and evaluation for conducting exfoliation tests on aluminum alloys in both laboratory accelerated environments and in natural, outdoor atmospheres. The intent is to clarify any gaps in existent test methods. 1.3 The values stated in SI units are to be regarded as the standard. The inch-pound units given in parentheses are for information only. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  15. Towards single screening tests for brucellosis

    DEFF Research Database (Denmark)

    Nielsen, K.; Smith, P.; Yu, W.

    2005-01-01

    This paper describes an indirect enzyme-linked immunosorbent assay (I-ELISA) and a fluorescence polarisation assay (FPA), each capable of detecting antibody in several species of hosts to smooth and rough members of the genus Brucella. The I-ELISA uses a mixture of smooth lipopolysaccharide (SLPS...... than did I-ELISA procedures using each individual antigen separately. Similarly, the assay using combined antigens detected antibody in slightly fewer animals not exposed to Brucella sp. When a universal cutoff of 10% positivity was used (relative to strongly positive control sera of each species......-ELISA and the FPA with combined antigens were suitable as screening tests for all species of Brucella in the animal species tested....

  16. Slovak Office of Standards, Metrology and Testing. Annual Report 2001

    International Nuclear Information System (INIS)

    2002-01-01

    A brief account of activities carried out by the Slovak Office of Standards, Metrology and Testing of the Slovak Republic in 2001 is presented. These activities are reported under the headings: (1) Introduction by the President of the Slovak Office of Standards, Metrology and Testing; (2) The Vice-president's Unit Standardization and Quality; (3) The President's Office; (4) Chief Inspector Department; (5) Legislative-juridical Department; (6) Department of Economy; (7) Department of International Co-operation; (8) Department of European Integration; (9) Department of Metrology; (10) Department of Testing; (11) Department of the Cyclotron Centre SR; (12) Slovak Institute of Metrology; (13) Slovak Standards Institution; (14) Slovak Metrology Inspectorate; (15) Slovak Legal Metrology; (16) Measuring Techniques - Technocentre - MTT; Abbreviations; (17) Technical Testing Institute Piestany; (18) Testing Institute of Transport and Earthmoving Machinery - SUDST

  17. Cognitive Fatigue Influences Students’ Performance on Standardized Tests

    DEFF Research Database (Denmark)

    Sievertsen, Hans Henrik; Gino, Francesca; Piovesan, Marco

    2016-01-01

    We identify one potential source of bias that influences children’s performance on standardized tests and that is predictable based on psychological theory: the time at which students take the test. Using test data for all children attending Danish public schools between school years 2009...

  18. Eight Ways to Support Students during Standardized Tests. Classroom Tips

    Science.gov (United States)

    Higdon, Julie; Holcomb, Linda Laine

    2012-01-01

    Standardized testing time often creates a nervous atmosphere in classrooms. In past years one of the authors joined a chorus of teachers singing her own woes about the infamous test. She increased her daily caffeine intake, lost sleep, and became a nervous, crazed teacher who had turned her classroom into a test prep center. Her aha moment came…

  19. Pad-weighing test performed with standardized bladder volume

    DEFF Research Database (Denmark)

    Lose, G; Rosenkilde, P; Gammelgaard, J

    1988-01-01

    The result of the one-hour pad-weighing test proposed by the International Continence Society has been demonstrated to depend on the urine load during the test. To increase reproducibility of the pad-weighing test by minimizing the influence of variation in urine load the test was done...... with a standardized bladder volume (50% of the cystometric bladder capacity). Twenty-five female patients with stress or mixed incontinence underwent two separate tests. Test-retest results were highly correlated (r = 0.97, p less than 0.001). Nonetheless, analysis of test-retest differences revealed a variation up...... to +/- 24 g between two tests. It is concluded that this setup (i.e., standardized bladder volume) of the one-hour pad-weighing test allows for a more reliable assessment of urinary incontinence for quantitative purposes....

  20. Standardization of food allergen extracts for skin prick test

    DEFF Research Database (Denmark)

    Skamstrup Hansen, K; Bindslev-Jensen, C; Skov, P S

    2001-01-01

    The aim of the study was to standardize and evaluate technically optimized food allergen extracts for use in skin prick test (SPT). The standardization procedure comprised 36 allergic histories in 32 food allergic patients with 21 healthy, non-atopic individuals serving as controls. The patients......-blind, placebo-controlled food challenge, except for the hazelnut-allergic patients. The controls were subjected to an open food challenge with all the foods to ensure tolerance. The standardization was performed by means of titrated SPT in accordance with the guidelines on biological standardization from...

  1. Standard Test Method for Environmental Resistance of Aerospace Transparencies

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This test method covers determination of the effects of exposure to thermal shock, condensing humidity, and simulated weather on aerospace transparent enclosures. 1.2 This test method is not recommended for quality control nor is it intended to provide a correlation to actual service life. 1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3.1 Exceptions—Certain inch-pound units are furnished in parentheses (not mandatory) and certain temperatures in Fahrenheit associated with other standards are also furnished. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  2. Zirconia crowns - the new standard for single-visit dentistry?

    Science.gov (United States)

    Wiedhahn, Klaus; Fritzsche, Günter; Wiedhahn, Claudine; Schenk, Olaf

    2016-01-01

    Zirconia crowns combine the advantages of metal restorations, such as minimally invasive tooth preparation and ease of cementation, with those of full ceramic crowns, such as low thermal conductivity and tooth color. With the introduction of a high-speed sintering procedure, it is possible to produce and cement zirconia crowns and small monolithic bridges in a Cerec Single Visit procedure. This new procedure is compared to established chairside methods.

  3. Standard practice for conducting atmospheric corrosion tests on metals

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This practice covers and defines conditions for exposure of metals and alloys to the weather. It sets forth the general procedures that should be followed in any atmospheric test. It is presented as an aid in conducting atmospheric corrosion tests so that some of the pitfalls of such testing may be avoided. As such, it is concerned mainly with panel exposures to obtain data for comparison purposes. 1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of whoever uses this standard to consult and establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  4. Evaluation of Suitability of Non-Standardized Test Block for Ultrasonic Testing

    International Nuclear Information System (INIS)

    Kwon, Ho Young; Lim, Jong Ho; Kang, Sei Sun

    2000-01-01

    Standard Test Block(STB) for UT(Ultrasonic Testing) is a block approved by authoritative for material, shape and quality. STB is used for characteristic tests, sensitivity calibration and control of the time base range of UT inspection devices. The material, size and chemical components of STB should be strictly controlled to meet the related standards such as ASTM and JIS because it has an effect upon sensitivity, resolution and reproductivity of UT. The STBs which are not approved are sometimes used because the qualified STBs are very expensive. So, the purpose of this study is to survey the characteristics, quality and usability of Non-Standardized Test Blocks. Non-Standardized Test Blocks did not meet the standard requirements in size or chemical components, and ultrasonic characteristics. Therefore if the Non-Standardized Test Blocks are used without being tested, it's likely to cause errors in detecting the location and measuring the size of the defects

  5. Standards for Educational and Psychological Testing, 2014 Edition

    Science.gov (United States)

    American Educational Research Association (AERA), 2014

    2014-01-01

    Developed jointly by the American Educational Research Association, American Psychological Association, and the National Council on Measurement in Education, "Standards for Educational and Psychological Testing" (Revised 2014) addresses professional and technical issues of test development and use in education, psychology, and…

  6. CONSTRUCTION AND STANDARDIZATION OF A BATTERY OF BRAILLE SKILL TESTS.

    Science.gov (United States)

    BOURGEAULT, STANLEY E.; WOODCOCK, RICHARD W.

    A BATTERY OF TESTS WAS DEVELOPED AND STANDARDIZED TO MEASURE MASTERY OF TWO BRAILLE CODES--THE GRADE 2 LITERARY CODE AND THE NEMETH CODE FOR MATHEMATICAL NOTATION. DESIGNATED AS THE "COLORADO BRAILLE BATTERY," THESE TESTS PROVIDED OBJECTIVE MEASUREMENT DATA REGARDING A STUDENT'S OVERALL DEVELOPMENT IN BRAILLE, AS WELL AS A MEANS OF…

  7. Standard Guide for Conducting Corrosion Tests in Field Applications

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 This guide covers procedures for conducting corrosion tests in plant equipment or systems under operating conditions to evaluate the corrosion resistance of engineering materials. It does not cover electrochemical methods for determining corrosion rates. 1.1.1 While intended primarily for immersion tests, general guidelines provided can be applicable for exposure of test specimens in plant atmospheres, provided that placement and orientation of the test specimens is non-restrictive to air circulation. 1.2 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. See also 10.4.2.

  8. THE STANDARD SINGLE COST METHOD AND THE EFFICIENCY OF INDUSTRIAL COMPANIES’ MANAGEMENT

    Directory of Open Access Journals (Sweden)

    Claudiu C. CONSTANTINESCU

    2008-12-01

    Full Text Available This article briefly describes the premises for the application of the standard direct cost calculation method in industry, the standard single cost calculation method, the stages of standard cost calculation per product and the calculation methods of standards per product. It also briefly underlines the possibilities of cost calculation and monitoring of deviation of the costs of raw materials and other materials as compared to the pre-established standard costs.

  9. [Discussion on the standard of clinical genetic testing report and the consensus of gene testing industry].

    Science.gov (United States)

    Huang, Hui; Shen, Yiping; Gu, Weihong; Wang, Wei; Wang, Yiming; Qi, Ming; Shen, Jun; Qiu, Zhengqing; Yu, Shihui; Zhou, Zaiwei; Chen, Baixue; Chen, Lei; Chen, Yundi; Cui, Huanhuan; Du, Juan; Gao, Yong; Guo, Yiran; Hu, Chanjuan; Hu, Liang; Huang, Yi; Li, Peipei; Li, Xiaorong; Li, Xiurong; Liu, Yaping; Lu, Jie; Ma, Duan; Ma, Yongyi; Peng, Mei; Song, Fang; Sun, Hongye; Wang, Liang; Wang, Dawei; Wang, Jingmin; Wang, Ling; Wang, Zhengyuan; Wang, Zhinong; Wu, Jihong; Wu, Jing; Wu, Jian; Xu, Yimin; Yao, Hong; Yang, Dongsheng; Yang, Xu; Yang, Yanling; Zhang, Ying; Zhou, Yulin; Zhu, Baosheng; Zeng, Sicong; Peng, Zhiyu; Huang, Shangzhi

    2018-02-10

    The widespread application of next generation sequencing (NGS) in clinical settings has enabled testing, diagnosis, treatment and prevention of genetic diseases. However, many issues have arisen in the meanwhile. One of the most pressing issues is the lack of standards for reporting genetic test results across different service providers. The First Forum on Standards and Specifications for Clinical Genetic Testing was held to address the issue in Shenzhen, China, on October 28, 2017. Participants, including geneticists, clinicians, and representatives of genetic testing service providers, discussed problems of clinical genetic testing services across in China and shared opinions on principles, challenges, and standards for reporting clinical genetic test results. Here we summarize expert opinions presented at the seminar and report the consensus, which will serve as a basis for the development of standards and guidelines for reporting of clinical genetic testing results, in order to promote the standardization and regulation of genetic testing services in China.

  10. BRCA Testing by Single-Molecule Molecular Inversion Probes

    NARCIS (Netherlands)

    Neveling, K.; Mensenkamp, A.R.; Derks, R; Kwint, M.P.; Ouchene, H.; Steehouwer, M.; Lier, L.A. van; Bosgoed, E.A.J.; Rikken, A.; Tychon, M.W.J.; Zafeiropoulou, D.; Castelein, S.; Hehir-Kwa, J.Y.; Thung, G.W.; Hofste, T.; Lelieveld, S.H.; Bertens, S.M.; Adan, I.B.; Eijkelenboom, A.; Tops, B.B.J.; Yntema, H.G.; Stokowy, T.; Knappskog, P.M.; Hoberg-Vetti, H.; Steen, V.M.; Boyle, E.; Martin, B.; Ligtenberg, M.J.L.; Shendure, J.; Nelen, M.R.; Hoischen, A.

    2017-01-01

    BACKGROUND: Despite advances in next generation DNA sequencing (NGS), NGS-based single gene tests for diagnostic purposes require improvements in terms of completeness, quality, speed, and cost. Single-molecule molecular inversion probes (smMIPs) are a technology with unrealized potential in the

  11. Single-port retroperitoneal renal biopsy using standard urological instruments

    Directory of Open Access Journals (Sweden)

    Rodrigo Guerra

    2015-02-01

    Full Text Available Objective To describe the surgical technique and initial experience with a single-port retroperitoneal renal biopsy (SPRRB. Materials and Methods Between January and April 2013, five children underwent SPRRB in our hospital. A single 1.5 cm incision was performed under the 12th rib at mid-axillary line, and an 11 mm trocar was inserted. A nephroscope was used to identify the kidney and dissect the perirenal fat. After lower pole exposure, a laparoscopic biopsy forceps was introduced through the nephroscope working channel to collect a renal tissue sample. Results SPRRB was successfully performed in five children. The mean operative time was 32 minutes, and mean estimated blood loss was less than 10 mL. The hospital stay of all patients was two days because they were discharged in the second postoperative day, after remaining at strict bed rest for 24 hours after the procedure. The average number of glomeruli present in the specimen was 31. Conclusion SPRRB is a simple, safe and reliable alternative to open and videolaparoscopic approaches to surgical renal biopsy.

  12. Single-shell tank riser resistance to ground test plan

    International Nuclear Information System (INIS)

    Kiewert, L.R.

    1996-01-01

    This Test Procedure provides the general directions for conducting Single-Shell Tank Riser to Earth Measurements which will be used by engineering as a step towards providing closure for the Lightning Hazard Issue

  13. Standard practice for modified salt spray (fog) testing

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This practice covers and sets forth conditions for five modifications in salt spray (fog) testing for specification purposes. These are in chronological order of their development: 1.1.1 Annex A1, acetic acid-salt spray test, continuous. 1.1.2 Annex A2, cyclic acidified salt spray test. 1.1.3 Annex A3, seawater acidified test, cyclic (SWAAT). 1.1.4 Annex A4, SO2 salt spray test, cyclic. 1.1.5 Annex A5, dilute electrolyte cyclic fog dry test. 1.2 This practice does not prescribe the type of modification, test specimen or exposure periods to be used for a specific product, nor the interpretation to be given to the results. 1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to consult and establish appropriate safety and health practices and determine the applicabilit...

  14. PROPOSAL FOR NEW WORLD STANDARD FOR TESTING SOLAR COOKERS

    Directory of Open Access Journals (Sweden)

    ASHOK KUNDAPUR

    2009-09-01

    Full Text Available New protocol to test solar cooker is being proposed. The earlier tests measured only the thermal efficiency. There is an urgent need to look into other important parameters of the cooker such as its stagnation capacity, cost per watts delivered, weight of the cooker, ease of handling and aesthetics. The proposal also aims at standardization of reporting the test results so that it can be easily understood by common persons who wishes to use one.

  15. The Development and Validation of the Test Of Astronomy STandards (TOAST)

    Science.gov (United States)

    Slater, Stephanie J.

    2014-01-01

    The Test Of Astronomy STandards (TOAST) is a comprehensive assessment instrument designed to measure students' general astronomy content knowledge. Built upon the research embedded within a generation of astronomy assessments designed to measure single concepts, the TOAST is appropriate to measure across an entire astronomy course. The TOAST's…

  16. Standard test method for conducting potentiodynamic polarization resistance measurements

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1997-01-01

    1.1 This test method covers an experimental procedure for polarization resistance measurements which can be used for the calibration of equipment and verification of experimental technique. The test method can provide reproducible corrosion potentials and potentiodynamic polarization resistance measurements. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  17. Fabrication and Testing of Pyramidal X- Band Standard Horn Antenna

    OpenAIRE

    Hasan F. Khazaal; Haider Th. Salim Alrikabi; Anwar N. Mohammed Ali; Kadhim A. Neamah; Ali S. Shanan

    2017-01-01

    Standard horn antennas are an important device to evaluate many types of antennas, since they are used as a reference to any type of antennas within the microwave frequency bands. In this project the fabrication process and tests of standard horn antenna operating at X-band frequencies have been proposed. The fabricated antenna passed through multi stages of processing of its parts until assembling the final product. These stages are (milling, bending, fitting and welding). The assembled ante...

  18. A single hole tracer test to determine longitudinal dispersion

    International Nuclear Information System (INIS)

    Noy, D.J.; Holmes, D.C.

    1986-03-01

    The paper concerns a single hole tracer test to determine longitudinal dispersion, which is an important parameter in assessing the suitability of a site for radioactive waste disposal. The theory, equipment and procedure for measuring longitudinal dispersion in a single borehole is described. Results are presented for field trials conducted in an aquifer, where the technique produced good results. The measured value of longitudinal dispersion, from a single hole test, relates only to a limited volume of rock immediately adjacent to the borehole. (U.K.)

  19. Standard Test Method for Abrasive Wear Resistance of Cemented

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2005-01-01

    1.1 This test method covers the determination of abrasive wear resistance of cemented carbides. 1.2 The values stated in inch-pound units are to be regarded as the standard. The SI equivalents of inch-pound units are in parentheses and may be approximate. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  20. Standard Test Method for Measured Speed of Oil Diffusion Pumps

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1982-01-01

    1.1 This test method covers the determination of the measured speed (volumetric flow rate) of oil diffusion pumps. 1.2 The values stated in inch-pound units are to be regarded as the standard. The metric equivalents of inch-pound units may be approximate. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  1. Standard Test Method for Determining Poisson's Ratio of Honeycomb Cores

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2002-01-01

    1.1 This test method covers the determination of the honeycomb Poisson's ratio from the anticlastic curvature radii, see . 1.2 The values stated in SI units are to be regarded as the standard. The inch-pound units given may be approximate. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  2. Standard Test Method for Shear Fatigue of Sandwich Core Materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2000-01-01

    1.1 This test method covers determination of the effect of repeated shear loads on sandwich core materials. 1.2 The values stated in SI units are to be regarded as the standard. The inch-pound units given may be approximate. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  3. Standard Test Method for Dimensional Stability of Sandwich Core Materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2002-01-01

    1.1 This test method covers the determination of the sandwich core dimensional stability in the two plan dimensions. 1.2 The values stated in SI units are to be regarded as the standard. The inch-pound units given may be approximate. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  4. DOE standard: Filter test facility quality program plan

    International Nuclear Information System (INIS)

    1999-02-01

    This standard was developed primarily for application in US Department of Energy programs. It contains specific direction for HEPA filter testing performed at a DOE-accepted HEPA Filter Test Facility (FTF). Beneficial comments (recommendations, additions, deletions) and any pertinent data that may improve this document should be sent to the Office of Nuclear Safety Policy and Standards (EH-31), US Department of Energy, Washington, DC 20585, by letter or by using the self-addressed Document Improvement Proposal form (DOE F 1300.3) appearing at the end of this document

  5. Assessing cultural validity in standardized tests in stem education

    Science.gov (United States)

    Gassant, Lunes

    This quantitative ex post facto study examined how race and gender, as elements of culture, influence the development of common misconceptions among STEM students. Primary data came from a standardized test: the Digital Logic Concept Inventory (DLCI) developed by Drs. Geoffrey L. Herman, Michael C. Louis, and Craig Zilles from the University of Illinois at Urbana-Champaign. The sample consisted of a cohort of 82 STEM students recruited from three universities in Northern Louisiana. Microsoft Excel and the Statistical Package for the Social Sciences (SPSS) were used for data computation. Two key concepts, several sub concepts, and 19 misconceptions were tested through 11 items in the DLCI. Statistical analyses based on both the Classical Test Theory (Spearman, 1904) and the Item Response Theory (Lord, 1952) yielded similar results: some misconceptions in the DLCI can reliably be predicted by the Race or the Gender of the test taker. The research is significant because it has shown that some misconceptions in a STEM discipline attracted students with similar ethnic backgrounds differently; thus, leading to the existence of some cultural bias in the standardized test. Therefore the study encourages further research in cultural validity in standardized tests. With culturally valid tests, it will be possible to increase the effectiveness of targeted teaching and learning strategies for STEM students from diverse ethnic backgrounds. To some extent, this dissertation has contributed to understanding, better, the gap between high enrollment rates and low graduation rates among African American students and also among other minority students in STEM disciplines.

  6. Similar tests and the standardized log likelihood ratio statistic

    DEFF Research Database (Denmark)

    Jensen, Jens Ledet

    1986-01-01

    When testing an affine hypothesis in an exponential family the 'ideal' procedure is to calculate the exact similar test, or an approximation to this, based on the conditional distribution given the minimal sufficient statistic under the null hypothesis. By contrast to this there is a 'primitive......' approach in which the marginal distribution of a test statistic considered and any nuisance parameter appearing in the test statistic is replaced by an estimate. We show here that when using standardized likelihood ratio statistics the 'primitive' procedure is in fact an 'ideal' procedure to order O(n -3...

  7. Design and testing of multi-standard waveguide couplers.

    Science.gov (United States)

    Beeson, S; Neuber, A

    2012-03-01

    Most applications that use waveguides are designed for a single frequency or single band of frequency, and thus the waveguide dimensions are chosen for single mode operation. In special cases where multiple frequencies across multiple bands are needed (i.e., probing the temporal response of decaying plasma using a cw source that is generated by a pulsed source), special techniques must be used in order to implement both sources into a single waveguide structure. This paper presents two types of couplers designed to implement x-band frequencies into an s-band system with a large coupling coefficient ( -10 dB) at the design frequency of 11 GHz. Along with a discussion on the design procedure, a detailed description on the parameter optimization and initial values estimation is presented. The custom waveguide structures were tested utilizing an Agilent E8364B PNA network analyzer, and showed reasonable agreement with the simulated performance over the frequency range of interest.

  8. Standardization of Solar Mirror Reflectance Measurements - Round Robin Test: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Meyen, S.; Lupfert, E.; Fernandez-Garcia, A.; Kennedy, C.

    2010-10-01

    Within the SolarPaces Task III standardization activities, DLR, CIEMAT, and NREL have concentrated on optimizing the procedure to measure the reflectance of solar mirrors. From this work, the laboratories have developed a clear definition of the method and requirements needed of commercial instruments for reliable reflectance results. A round robin test was performed between the three laboratories with samples that represent all of the commercial solar mirrors currently available for concentrating solar power (CSP) applications. The results show surprisingly large differences in hemispherical reflectance (sh) of 0.007 and specular reflectance (ss) of 0.004 between the laboratories. These differences indicate the importance of minimum instrument requirements and standardized procedures. Based on these results, the optimal procedure will be formulated and validated with a new round robin test in which a better accuracy is expected. Improved instruments and reference standards are needed to reach the necessary accuracy for cost and efficiency calculations.

  9. Standard Test Method for Laboratory Aging of Sandwich Constructions

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1999-01-01

    1.1 This test method covers the determination of the resistance of sandwich panels to severe exposure conditions as measured by the change in selected properties of the material after exposure. The exposure cycle to which the specimen is subjected is an arbitrary test having no correlation with natural weathering conditions. 1.2 The values stated in SI units are to be regarded as the standard. The inch-pound units given may be approximate. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  10. Standard Test Method for Thermal Oxidative Resistance of Carbon Fibers

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1982-01-01

    1.1 This test method covers the apparatus and procedure for the determination of the weight loss of carbon fibers, exposed to ambient hot air, as a means of characterizing their oxidative resistance. 1.2 The values stated in SI units are to be regarded as standard. The values given in parentheses are mathematical conversions to inch-pound units which are provided for information only and are not considered standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific hazard information, see Section 8.

  11. Standardization of food allergen extracts for skin prick test

    DEFF Research Database (Denmark)

    Skamstrup Hansen, K; Bindslev-Jensen, C; Skov, P S

    2001-01-01

    The aim of the study was to standardize and evaluate technically optimized food allergen extracts for use in skin prick test (SPT). The standardization procedure comprised 36 allergic histories in 32 food allergic patients with 21 healthy, non-atopic individuals serving as controls. The patients...... had a history of allergic symptoms upon ingestion of either cow's milk (n=3), hen's egg (n=9), wheat (n=4), hazelnut (n=14) or cod (n=6). They also had specific IgE in serum to the food in question and a positive SPT with a fresh preparation of the food. The diagnosis had been confirmed by a double......-blind, placebo-controlled food challenge, except for the hazelnut-allergic patients. The controls were subjected to an open food challenge with all the foods to ensure tolerance. The standardization was performed by means of titrated SPT in accordance with the guidelines on biological standardization from...

  12. Standardized Testing and School Segregation: Like Tinder for Fire?

    Science.gov (United States)

    Knoester, Matthew; Au, Wayne

    2017-01-01

    Recent research suggests that high-stakes standardized testing has played a negative role in the segregation of children by race and class in schools. In this article we review research on the overall effects of segregation, the positive and negative aspects of how desegregation plans were carried out following the 1954 Supreme Court decision…

  13. Report on the Standardization Project "Formal Methods in Conformance Testing"

    NARCIS (Netherlands)

    Baumgarten, B.; Hogrefe, D.; Heymer, S.; Burkhardt, H.-J.; Giessler, A.; Tretmans, G.J.

    1996-01-01

    This paper presents the latest developments in the “Formal Methods in Conformance Testing��? (FMCT) project of ISO and ITU–T. The project has been initiated to study the role of formal description techniques in the conformance testing process. The goal is to develop a standard that defines the

  14. Non-standard testing of mechanical characteristics of historic mortars

    Czech Academy of Sciences Publication Activity Database

    Drdácký, Miloš

    2011-01-01

    Roč. 5, 4-5 (2011), s. 383-394 ISSN 1558-3058 R&D Projects: GA ČR(CZ) GA103/09/2067 Institutional research plan: CEZ:AV0Z20710524 Keywords : non-standard test specimen * historic mortar * compressive strength Subject RIV: AL - Art, Architecture, Cultural Heritage Impact factor: 0.235, year: 2011

  15. Corporate Schooling Meets Corporate Media: Standards, Testing, and Technophilia

    Science.gov (United States)

    Saltman, Kenneth J.

    2016-01-01

    Educational publishing corporations and media corporations in the United States have been converging, especially through the promotion of standardization, testing, and for-profit educational technologies. Media and technology companies--including News Corp, Apple, and Microsoft--have significantly expanded their presence in public schools to sell…

  16. Development of Standardized Material Testing Protocols for Prosthetic Liners.

    Science.gov (United States)

    Cagle, John C; Reinhall, Per G; Hafner, Brian J; Sanders, Joan E

    2017-04-01

    A set of protocols was created to characterize prosthetic liners across six clinically relevant material properties. Properties included compressive elasticity, shear elasticity, tensile elasticity, volumetric elasticity, coefficient of friction (CoF), and thermal conductivity. Eighteen prosthetic liners representing the diverse range of commercial products were evaluated to create test procedures that maximized repeatability, minimized error, and provided clinically meaningful results. Shear and tensile elasticity test designs were augmented with finite element analysis (FEA) to optimize specimen geometries. Results showed that because of the wide range of available liner products, the compressive elasticity and tensile elasticity tests required two test maxima; samples were tested until they met either a strain-based or a stress-based maximum, whichever was reached first. The shear and tensile elasticity tests required that no cyclic conditioning be conducted because of limited endurance of the mounting adhesive with some liner materials. The coefficient of friction test was based on dynamic coefficient of friction, as it proved to be a more reliable measurement than static coefficient of friction. The volumetric elasticity test required that air be released beneath samples in the test chamber before testing. The thermal conductivity test best reflected the clinical environment when thermal grease was omitted and when liner samples were placed under pressure consistent with load bearing conditions. The developed procedures provide a standardized approach for evaluating liner products in the prosthetics industry. Test results can be used to improve clinical selection of liners for individual patients and guide development of new liner products.

  17. 49 CFR 232.305 - Single car air brake tests.

    Science.gov (United States)

    2010-10-01

    ... from a train or when placed on a shop or repair track, as defined in § 232.303(a); (2) A car is on a shop or repair track, as defined in § 232.303(a), for any reason and has not received a single car air... 49 Transportation 4 2010-10-01 2010-10-01 false Single car air brake tests. 232.305 Section 232...

  18. How meaningful are risk determinations in the absence of a complete dataset? Making the case for publishing standardized test guideline and ‘no effect’ studies for evaluating the safety of nanoparticulates versus spurious ‘high effect’ results from single investigative studies

    Science.gov (United States)

    Warheit, David B.; Donner, E. Maria

    2015-06-01

    A recent review article critically assessed the effectiveness of published research articles in nanotoxicology to meaningfully address health and safety issues for workers and consumers. The main conclusions were that, based on a number of flaws in study designs, the potential risk from exposures to nanomaterials is highly exaggerated, and that no ‘nano-specific’ adverse effects, different from exposures to bulk particles, have been convincingly demonstrated. In this brief editorial we focus on a related tangential issue which potentially compromises the integrity of basic risk science. We note that some single investigation studies report specious toxicity findings, which make the conclusions more alarming and attractive and publication worthy. In contrast, the standardized, carefully conducted, ‘guideline study results’ are often ignored because they can frequently report no adverse effects; and as a consequence are not considered as novel findings for publication purposes, and therefore they are never considered as newsworthy in the popular press. Yet it is the Organization for Economic Cooperation and Development (OECD) type test guideline studies that are the most reliable for conducting risk assessments. To contrast these styles and approaches, we present the results of a single study which reports high toxicological effects in rats following low-dose, short-term oral exposures to nanoscale titanium dioxide particles concomitant with selective investigative analyses. Alternatively, the findings of OECD test guideline 408, standardized guideline oral toxicity studies conducted for 90 days at much higher doses (1000 mg kg-1) in male and female rats demonstrated no adverse effects following a very thorough and complete clinical chemical, as well as histopathological evaluation of all of the relevant organs in the body. This discrepancy in study findings is not reconciled by the fact that several biokinetic studies in rats and humans demonstrate little or

  19. How meaningful are risk determinations in the absence of a complete dataset? Making the case for publishing standardized test guideline and ‘no effect’ studies for evaluating the safety of nanoparticulates versus spurious ‘high effect’ results from single investigative studies

    International Nuclear Information System (INIS)

    Warheit, David B; Donner, E Maria

    2015-01-01

    A recent review article critically assessed the effectiveness of published research articles in nanotoxicology to meaningfully address health and safety issues for workers and consumers. The main conclusions were that, based on a number of flaws in study designs, the potential risk from exposures to nanomaterials is highly exaggerated, and that no ‘nano-specific’ adverse effects, different from exposures to bulk particles, have been convincingly demonstrated. In this brief editorial we focus on a related tangential issue which potentially compromises the integrity of basic risk science. We note that some single investigation studies report specious toxicity findings, which make the conclusions more alarming and attractive and publication worthy. In contrast, the standardized, carefully conducted, ‘guideline study results’ are often ignored because they can frequently report no adverse effects; and as a consequence are not considered as novel findings for publication purposes, and therefore they are never considered as newsworthy in the popular press. Yet it is the Organization for Economic Cooperation and Development (OECD) type test guideline studies that are the most reliable for conducting risk assessments. To contrast these styles and approaches, we present the results of a single study which reports high toxicological effects in rats following low-dose, short-term oral exposures to nanoscale titanium dioxide particles concomitant with selective investigative analyses. Alternatively, the findings of OECD test guideline 408, standardized guideline oral toxicity studies conducted for 90 days at much higher doses (1000 mg kg −1 ) in male and female rats demonstrated no adverse effects following a very thorough and complete clinical chemical, as well as histopathological evaluation of all of the relevant organs in the body. This discrepancy in study findings is not reconciled by the fact that several biokinetic studies in rats and humans demonstrate

  20. Study on method of data standardization in interferometric testing

    Science.gov (United States)

    Chen, Wei

    2010-10-01

    As a rule, Interferometers are used to test the figure in the polishing phase of optical component, it could provide advance tutor suggestion for manufacturing. It is unable to get the whole wave-front interferogram usually because phase-shift Interferometry is sensitive to environment vibration, so the exactly interference data of the optical surface could not be obtained. Various spatial point on the tested optical component will be given by calculation method about arithmetic average value of equal accuracy is provied. This paper describes the testing results of optical components in size Φ1200mm, it is proved the method could eliminate the vibration effectively and get the standardization data.

  1. Impact of standard test protocols on sporicidal efficacy.

    Science.gov (United States)

    Wesgate, R; Rauwel, G; Criquelion, J; Maillard, J-Y

    2016-07-01

    There has been an increase in the availability of commercial sporicidal formulations. Any comparison of sporicidal data from the literature is hampered by the number of different standard tests available and the use of diverse test conditions including bacterial strains and endospore preparation. To evaluate the effect of sporicidal standard tests on the apparent activity of eight biocides against Clostridium difficile and Bacillus subtilis. The activity of eight biocidal formulations including two oxidizing agents, two aldehydes, three didecyldimethylammonium chloride (DDAC) and amine formulations, and sodium hypochlorite were evaluated using four standard sporicidal tests (BS EN 14347, BS EN13704, ASTM E2197-11, and AOAC MB-15-03) against B. subtilis (ACTC 19659) and C. difficile (NCTC 11209) spores. C. difficile spores were more susceptible to the sporicides than were B. subtilis spores, regardless of the method used. There were differences in sporicidal activity between methods at 5 min but not at 60 min exposure. DDAC and amine-based products were not sporicidal when neutralized appropriately. Neutralization validation was confirmed for these biocides using the reporting format described in the BS EN standard tests, although the raw data appear to indicate that neutralization failed. The different methods, whether based on suspension or carrier tests, produced similar sporicidal inactivation data. This study suggests that detailed neutralization validation data should be reported to ensure that neutralization of active spores is effective. Failure to do so may lead to erroneous sporicidal claims. Copyright © 2016 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  2. Standard Practice for Quality Management Systems for Nondestructive Testing Agencies

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This practice covers general requirements for the establishment and maintenance of a quality management system for agencies engaged in nondestructive testing (NDT). 1.2 This practice utilizes criteria contained in Practice E 543. 1.3 This practice utilizes criteria contained in American National Standard ANSI/ISO/ASQ Q9001–2000, Quality management systems—Requirements. 1.4 This practice recognizes the importance of establishing minimum safety criteria. 1.5 The use of SI or inch-pound units, or combinations thereof, will be the responsibility of the technical committee whose standards are referred to in this standard. 1.6 This practice does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this practice to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  3. Standard test method for macroetching metals and alloys

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2000-01-01

    1.1 These test procedures describe the methods of macro- etching metals and alloys to reveal their macrostructure. 1.2 The values stated in inch-pound units are to be regarded as the standard. The SI equivalents of inch-pound units may be approximate. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific warning statements, see 6.2, 7.1, 8.1.3, 8.2.1, 8.8.3, 8.10.1.1, and 8.13.2.

  4. RF tests on the Etam Standard C antenna

    Science.gov (United States)

    Price, R.

    1982-05-01

    Radiometric measurements on the Etam Standard C antenna are described in this paper. Gain-to-noise temperature ratio (G/T), receive and transmit gain, noise temperature, return loss, and port-to-port isolation were measured, and communication and tracking patterns taken. Because of the very low spectral flux densities in the 14/11-GHz bands, it was necessary to use radiometric methods for measuring G/T, gain and temperature. Although in Standard A antennas Y-factors range between 3 and 6 dB, in Standard C antennas they are only 0.4-0.5 dB. Thus, errors and uncertainties, which are negligible in a 6/4-GHz test, become major at 14/11 GHz. This difficulty was overcome at Etam by applying a refinement in switched radiometry, which resulted in the collection of a large amount of useful data.

  5. Standard test methods for conducting time-for-rupture notch tension tests of materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 These test methods cover the determination of the time for rupture of notched specimens under conditions of constant load and temperature. These test methods also includes the essential requirements for testing equipment. 1.2 The values stated in inch-pound units are to be regarded as the standard. The units in parentheses are for information only. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  6. A new single-photon avalanche diode in 90nm standard CMOS technology

    NARCIS (Netherlands)

    Karami, M.A.; Gersbach, M.; Charbon, E.

    2010-01-01

    A single-photon avalanche diode (SPAD) fabricated in a 90nm standard CMOS process is reported. The detector comprises an octagonal multiplication region and a guard ring to prevent premature edge breakdown using exclusively standard layers. The proposed structure is the result of a systematic study

  7. Hybrid Testing of Composite Structures with Single-Axis Control

    DEFF Research Database (Denmark)

    Waldbjørn, Jacob Paamand; Høgh, Jacob Herold; Stang, Henrik

    2013-01-01

    Hybrid testing is a substructuring technique where a structure is emulated by modelling a part of it in a numerical model while testing the remainder experimentally. Previous research in hybrid testing has been performed on multi-component structures e.g. damping fixtures, however in this paper...... a hybrid testing platform is introduced for single-component hybrid testing. In this case, the boundary between the numerical model and experimental setup is defined by multiple Degrees-Of-Freedoms (DOFs) which highly complicate the transferring of response between the two substructures. Digital Image...... Correlation (DIC) is therefore implemented for displacement control of the experimental setup. The hybrid testing setup was verified on a multicomponent structure consisting of a beam loaded in three point bending and a numerical structure of a frame. Furthermore, the stability of the hybrid testing loop...

  8. European accelerator facilities for single event effects testing

    Energy Technology Data Exchange (ETDEWEB)

    Adams, L.; Nickson, R.; Harboe-Sorensen, R. [ESA-ESTEC, Noordwijk (Netherlands); Hajdas, W.; Berger, G.

    1997-03-01

    Single event effects are an important hazard to spacecraft and payloads. The advances in component technology, with shrinking dimensions and increasing complexity will give even more importance to single event effects in the future. The ground test facilities are complex and expensive and the complexities of installing a facility are compounded by the requirement that maximum control is to be exercised by users largely unfamiliar with accelerator technology. The PIF and the HIF are the result of experience gained in the field of single event effects testing and represent a unique collaboration between space technology and accelerator experts. Both facilities form an essential part of the European infrastructure supporting space projects. (J.P.N.)

  9. Model tests on single piles in soft clay

    Energy Technology Data Exchange (ETDEWEB)

    Pan, J.L. [Durham Univ., Durham, (United Kingdom). School of Engineering; Goh, A.T.C.; Wong, K.S.; Teh, C.I. [Nanyang Technological Univ., (Singapore). Geotechnical Research Centre

    2000-08-04

    The behaviour of single stainless steel piles subjected to lateral soft clay soil movement was investigated in laboratory model tests in an effort to determine the ultimate soil pressure acting along the pile shaft. A custom designed apparatus was manufactured and calibrated for the test which measured the limiting soil pressures acting along the model pile shaft. The ultimate soil pressure was determined based on the maximum value of this measurement. The results show that the ultimate soil pressure for single passive piles was about 10 times the undrained shear strength, and the magnitude of the soil translation needed to fully mobilize the ultimate soil pressure on the single passive piles was about half the pile width. Further experimental study is needed to examine the effects of the pile end fixity, flexibility and shape and to confirm the effects of sample size and the disturbance due to soil sample preparation. 17 refs., 10 figs.

  10. International standardization of instruments for neutron irradiation tests

    International Nuclear Information System (INIS)

    Tanimoto, Masataka; Shibata, Akira; Nakamura, Jinichi; Tsuchiya, Kunihiko; Cho, M.; Lee, C.; Park, S.; Choo, K.

    2012-01-01

    The JMTR in JAEA and HANARO in KAERI are the foremost testing/research reactors in the world and these are expected to contribute to many nuclear fields. As a part of instrument development in irradiation field, information exchange of instruments started from 2010 under the cooperation agreements between KAERI and JAEA. The instruments developed in JMTR and HANARO are introduced and cooperation experiments as future plan are discussed for international standardization. (author)

  11. Standard Waste Box Lid Screw Removal Option Testing

    Energy Technology Data Exchange (ETDEWEB)

    Anast, Kurt Roy [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-03-11

    This report provides results from test work conducted to resolve the removal of screws securing the standard waste box (SWB) lids that hold the remediated nitrate salt (RNS) drums. The test work evaluated equipment and process alternatives for removing the 42 screws that hold the SWB lid in place. The screws were secured with a red Loctite thread locker that makes removal very difficult because the rivets that the screw threads into would slip before the screw could be freed from the rivet, making it impossible to remove the screw and therefore the SWB lid.

  12. Fabrication and Testing of Pyramidal X- Band Standard Horn Antenna

    Directory of Open Access Journals (Sweden)

    Hasan F. Khazaal

    2017-11-01

    Full Text Available Standard horn antennas are an important device to evaluate many types of antennas, since they are used as a reference to any type of antennas within the microwave frequency bands. In this project the fabrication process and tests of standard horn antenna operating at X-band frequencies have been proposed. The fabricated antenna passed through multi stages of processing of its parts until assembling the final product. These stages are (milling, bending, fitting and welding. The assembled antenna subjected to two types of tests to evaluate its performance. The first one is the test by two port network analyzer to point out S & Z parameters, input resistance, and the voltage standing wave ratio of the horn, while the second test was done using un-echoic chamber to measure the gain, side lobes level and the half power beam width. The results of testing come nearly as a theoretical value of the most important of antenna parameters, like; gain, side lobe level, -3 dB beam width, return loss and voltage standing wave ratio "VSWR", input Impedance.

  13. Standard Test Method for Normal Spectral Emittance at Elevated Temperatures

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1972-01-01

    1.1 This test method describes a highly accurate technique for measuring the normal spectral emittance of electrically conducting materials or materials with electrically conducting substrates, in the temperature range from 600 to 1400 K, and at wavelengths from 1 to 35 μm. 1.2 The test method requires expensive equipment and rather elaborate precautions, but produces data that are accurate to within a few percent. It is suitable for research laboratories where the highest precision and accuracy are desired, but is not recommended for routine production or acceptance testing. However, because of its high accuracy this test method can be used as a referee method to be applied to production and acceptance testing in cases of dispute. 1.3 The values stated in SI units are to be regarded as the standard. The values in parentheses are for information only. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this stan...

  14. NedWind 25 Blade Testing at NREL for the European Standards Measurement and Testing Program

    Energy Technology Data Exchange (ETDEWEB)

    Larwood, S.; Musial, W.; Freebury, G.; Beattie, A.G.

    2001-04-19

    In the mid-90s the European community initiated the Standards, Measurements, and Testing (SMT) program to harmonize testing and measurement procedures in several industries. Within the program, a project was carried out called the European Wind Turbine Testing Procedure Development. The second part of that project, called Blade Test Methods and Techniques, included the United States and was devised to help blade-testing laboratories harmonize their testing methods. This report provides the results of those tests conducted by the National Renewable Energy Laboratory.

  15. Standard practice for conducting moist SO2 tests

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2002-01-01

    1.1 This practice covers the apparatus and procedure to be used in conducting qualitative assessment tests in accordance with the requirements of material or product specifications by means of specimen exposure to condensed moisture containing sulfur dioxide. 1.2 The exposure conditions may be varied to suit particular requirements and this practice includes provisions for use of different concentrations of sulfur dioxide and for tests either running continuously or in cycles of alternate exposure to the sulfur dioxide containing atmosphere and to the ambient atmosphere. 1.3 The variant of the test to be used, the exposure period required, the type of test specimen, and the criteria of failure are not prescribed by this practice. Such details are provided in appropriate material and product purchase specifications. 1.4 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only. 1.5 This standard does not purport to address all of the safety c...

  16. The Analysis of the Psychological Tests Using In Educational Institutions According To the Testing Standards

    Directory of Open Access Journals (Sweden)

    Ezgi MOR DİRLİK

    2017-12-01

    Full Text Available The purpose of this research is to analyze four psychological tests which are frequently used in the Guidance and Research Centers and in the guidance services of the schools according to the standards for educational and psychological testing of APA (American Psychological Association and test adaption standards of ITC (International Testing Commission. The tests were determined based on the goal- oriented sample selecting method and were selected from the most frequently used psychological tests in Guidance and Research Centers and school’s guidance centers. These tests are: Scale of Academic Self-Concept (Akademik Benlik Kavramı Ölçeği-ABKÖ, Evaluation of Early Childhood Development Tool (Gazi Erken Çocukluk Gelişimi Değerlendirme Aracı-GEÇDA, Primary Mental Abilities 7-11 (TKT 7-11, and Wechsler Intelligence Scale for Children Revised Form (WISC-R. In this research, the chapters related to the validity, reliability and test development and revision of “Standards For Educational And Psychological Testing” (APA, 1999 and the adaptation standards developed by ITC were translated into Turkish and a checklist was created by using these documents. The checklist has got two forms as short and long form. The tests were analyzed according to the short form of the checklist by researcher. In order to examine the reliability of these analyses, the analyses were repeated in three weeks’ time. Data of these analyses were exported to the Statistical Package for Social Sciences (SPSS 20.0 and descriptive analysis was perfomed. As a result of this research, the meeting levels of the psychological tests to the test standards in the checklist and the features of the tests which should be improved according to the validity, reliability, test development and revision and test adaptation were determined. In conclusion, the standards analyzed have not been met satisfactorily by ABKÖ and GEÇDA, and according to the analyses of the realibility

  17. The Standard-Model Extension and Gravitational Tests

    Directory of Open Access Journals (Sweden)

    Jay D. Tasson

    2016-10-01

    Full Text Available The Standard-Model Extension (SME provides a comprehensive effective field-theory framework for the study of CPT and Lorentz symmetry. This work reviews the structure and philosophy of the SME and provides some intuitive examples of symmetry violation. The results of recent gravitational tests performed within the SME are summarized including analysis of results from the Laser Interferometer Gravitational-Wave Observatory (LIGO, sensitivities achieved in short-range gravity experiments, constraints from cosmic-ray data, and results achieved by studying planetary ephemerids. Some proposals and ongoing efforts will also be considered including gravimeter tests, tests of the Weak Equivalence Principle, and antimatter experiments. Our review of the above topics is augmented by several original extensions of the relevant work. We present new examples of symmetry violation in the SME and use the cosmic-ray analysis to place first-ever constraints on 81 additional operators.

  18. Standard Test Method for Bird Impact Testing of Aerospace Transparent Enclosures

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This test method covers conducting bird impact tests under a standard set of conditions by firing a packaged bird at a stationary transparency mounted in a support structure. 1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements, see Section 8.

  19. Standard Test Method for Cavitation Erosion Using Vibratory Apparatus

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This test method covers the production of cavitation damage on the face of a specimen vibrated at high frequency while immersed in a liquid. The vibration induces the formation and collapse of cavities in the liquid, and the collapsing cavities produce the damage to and erosion (material loss) of the specimen. 1.2 Although the mechanism for generating fluid cavitation in this method differs from that occurring in flowing systems and hydraulic machines (see 5.1), the nature of the material damage mechanism is believed to be basically similar. The method therefore offers a small-scale, relatively simple and controllable test that can be used to compare the cavitation erosion resistance of different materials, to study in detail the nature and progress of damage in a given material, or—by varying some of the test conditions—to study the effect of test variables on the damage produced. 1.3 This test method specifies standard test conditions covering the diameter, vibratory amplitude and frequency of the...

  20. Standard practice for torque calibration of testing machines and devices

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This practice covers procedures and requirements for the calibration of torque for static and quasi-static torque capable testing machines or devices. These may, or may not, have torque indicating systems and include those devices used for the calibration of hand torque tools. Testing machines may be calibrated by one of the three following methods or combination thereof: 1.1.1 Use of standard weights and lever arms. 1.1.2 Use of elastic torque measuring devices. 1.1.3 Use of elastic force measuring devices and lever arms. 1.1.4 Any of the methods require a specific uncertainty of measurement and a traceability derived from national standards of mass and length. 1.2 The procedures of 1.1.1, 1.1.2, and 1.1.3 apply to the calibration of the torque-indicating systems associated with the testing machine, such as a scale, dial, marked or unmarked recorder chart, digital display, etc. In all cases the buyer/owner/user must designate the torque-indicating system(s) to be calibrated and included in the repor...

  1. Alternate performance standard project: Interpreting the post-construction test

    International Nuclear Information System (INIS)

    Williamson, A.D.; McDonough, S.E.

    1993-01-01

    The paper describes the results of a project commissioned by the State of Florida, in cooperation with the US Environmental Protection Agency, as one portion of the Florida Radon Research Program (FRRP). The purpose of the FRRP is to provide technical support for a statewide Building Standard for Radon-Resistant Construction currently in the rulemaking process. In this case the information provides technical background for a post-construction radon test specified as a performance element of the code which accompanies the prescriptive alternative that does not incorporate active radon reduction systems

  2. ANSI / FM Approvals 2510 flood abatement equipment test standard

    Directory of Open Access Journals (Sweden)

    Kravetz Frédéric

    2016-01-01

    Full Text Available Natural hazards, including flooding, continue to be the leading cause of commercial and industrial property damage worldwide. Until recently, there has been a limited amount of readily available guidance on choosing flood abatement protection. FM Approvals, a division of FM Global, one of the world’s largest business property insurers, working together with the Association of State Floodplain Managers and the US Army Corps of Engineers have developed a National Flood Barrier Test Program after recognizing the urgent demand for reliable flood abatement products to mitigate potential losses. This lead to the ANSI/ FM2510 flood abatement equipment standard.

  3. Key challenges for nanotechnology: Standardization of ecotoxicity testing.

    Science.gov (United States)

    Cerrillo, Cristina; Barandika, Gotzone; Igartua, Amaya; Areitioaurtena, Olatz; Mendoza, Gemma

    2017-04-03

    Nanotechnology is expected to contribute to the protection of the environment, but many uncertainties exist regarding the environmental and human implications of manufactured nanomaterials (MNMs). Contradictory results have been reported for their ecotoxicity to aquatic organisms, which constitute one of the most important pathways for their entrance and transfer throughout the food web. The present review is focused on the international strategies that are laying the foundations of the ecotoxicological assessment of MNMs. Specific advice is provided on the preparation of MNM dispersions in the culture media of the organisms, which is considered a key factor to overcome the limitations in the standardization of the test methodologies.

  4. Standard test method for measuring pH of soil for use in corrosion testing

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1995-01-01

    1.1 This test method covers a procedure for determining the pH of a soil in corrosion testing. The principle use of the test is to supplement soil resistivity measurements and thereby identify conditions under which the corrosion of metals in soil may be accentuated (see G 57 - 78 (1984)). 1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  5. Standard Specification for Solar Simulation for Terrestrial Photovoltaic Testing

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This specification provides means for classifying solar simulators intended for indoor testing of photovoltaic devices (solar cells or modules), according to their spectral match to a reference spectral irradiance, non-uniformity of spatial irradiance, and temporal instability of irradiance. 1.2 Testing of photovoltaic devices may require the use of solar simulators. Test Methods that require specific classification of simulators as defined in this specification include Test Methods E948, E1036, and E1362. 1.3 This standard is applicable to both pulsed and steady state simulators and includes recommended test requirements used for classifying such simulators. 1.4 A solar simulator usually consists of three major components: (1) light source(s) and associated power supply; (2) any optics and filters required to modify the output beam to meet the classification requirements in Section 4; and (3) the necessary controls to operate the simulator, adjust irradiance, etc. 1.5 A light source that does not mee...

  6. Earthquake acceleration amplification based on single microtremor test

    Science.gov (United States)

    Jaya Syahbana, Arifan; Kurniawan, Rahmat; Soebowo, Eko

    2018-02-01

    Understanding soil dynamics is needed to understand soil behaviour, including the parameters of earthquake acceleration amplification. Many researchers now conduct single microtremor tests to obtain amplification of velocity and natural periods of soil at test sites. However, these amplification parameters are rarely used, so a method is needed to convert the velocity amplification to acceleration amplification. This paper will discuss the proposed process of changing the value of amplification. The proposed method is to integrate the time histories of the synthetic earthquake acceleration of the soil surface under the deaggregation at that location so the time histories of the velocity earthquake will be obtained. Next is to conduct a “fitting curve” between amplification by a single microtremor test with amplification of the synthetic earthquake velocity time histories. After obtaining the fitting curve time histories of velocity, differentiation will be conducted to obtain fitting curve acceleration time histories. The final step after obtaining the fitting curve is to compare the acceleration of the “fitting curve” against the histories time of the acceleration of synthetic earthquake at bedrocks to obtain single microtremor acceleration amplification factor.

  7. Standard test methods for notched bar impact testing of metallic materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2007-01-01

    1.1 These test methods describe notched-bar impact testing of metallic materials by the Charpy (simple-beam) test and the Izod (cantilever-beam) test. They give the requirements for: test specimens, test procedures, test reports, test machines (see Annex A1) verifying Charpy impact machines (see Annex A2), optional test specimen configurations (see Annex A3), precracking Charpy V-notch specimens (see Annex A4), designation of test specimen orientation (see Annex A5), and determining the percent of shear fracture on the surface of broken impact specimens (see Annex A6). In addition, information is provided on the significance of notched-bar impact testing (see Appendix X2), methods of measuring the center of strike (see Appendix X2). 1.2 These test methods do not address the problems associated with impact testing at temperatures below -196 C (-320 F, 77 K). 1.3 The values stated in SI units are to be regarded as the standard. Inch-pound units are provided for information only. This standard does not purpor...

  8. Background Variables, Levels of Aggregation, and Standardized Test Scores

    Directory of Open Access Journals (Sweden)

    Sharon E. Paulson

    2009-12-01

    Full Text Available This article examines the role of student demographic characteristics in standardized achievement test scores at both the individual level and aggregated at the state, district, school levels. For several data sets, the majority of the variance among states, districts, and schools was related to demographic characteristics. Where these background variables outside of the control of schools significantly affected averaged scores, and test scores result in high stakes consequences, benefits and sanctions may be inappropriately applied. Furthermore, disaggregating the data by race, SES, limited English, or other groupings ignores the significant confounding and cumulative effects of belonging to more than one disadvantaged group. With these approaches to evaluation being fundamental to the No Child Left Behind mandates, the danger of misinterpretation and inappropriate application of sanctions is substantial.

  9. Filtration: Novel Absorber Evaluation Club aims at standardized testing

    International Nuclear Information System (INIS)

    Anon.

    1990-01-01

    In the past few years a number of novel absorber materials, both organic and inorganic, have appeared on the market - some claiming to achieve very large decontamination factors for metal ions, including those having radioactive isotopes. Several of these materials have been tested by individual companies in the nuclear industry and some have shown promise as decontaminants for radioactive waste streams. Unfortunately, the results obtained for the treatment of a particular waste stream cannot be applied directly to the many and diverse waste streams generated throughout the nuclear industry. A unified and standardized testing programme making use of available expertise is necessary to provide a fair and meaningful comparison. In November 1988, representatives of the United Kingdom nuclear industry agreed to form the Novel Absorber Evaluation Club to assess absorber materials and to undertake the necessary work to identify the extent and rate of adsorption of radionuclides by such materials from a set of typical reference waste streams. (author)

  10. Tests of the standard model and searches for new physics

    Energy Technology Data Exchange (ETDEWEB)

    Langacker, Paul [Pennsylvania Univ., PA (United States). Dept. of Physics

    1996-07-01

    Earlier chapters of this volume have detailed described the standard model and its renormalization, the various types of precision experiments, and their implications. This chapter is devoted to global analysis of the Z-pole, M{sub W}, and neutral current data, which contains more information that any one class of experiments. The subsequent sections will summarize some of the relevant data and theoretical formulas, the status of the standard model tests and parameter determinations, the possible classes of new physics, and the implications of the precision experiments. In particular, the model independent analysis of neutral current couplings, which establishes the standard model to first approximation; the implication of supersymmetry; supersymmetric grand unification; and a number if specific types of new physics, including heavy Z{sup '} bosons, new sources of SU{sub 2} breaking, new contributions to the gauge boson self-energies, Zb b-bar vertex corrections, certain types of new 4-Fermi operators and leptoquarks, and the exotic fermions are described.

  11. Stress-testing the Standard Model at the LHC

    CERN Document Server

    2016-01-01

    With the high-energy run of the LHC now underway, and clear manifestations of beyond-Standard-Model physics not yet seen in data from the previous run, the search for new physics at the LHC may be a quest for small deviations with big consequences. If clear signals are present, precise predictions and measurements will again be crucial for extracting the maximum information from the data, as in the case of the Higgs boson. Precision will therefore remain a key theme for particle physics research in the coming years. The conference will provide a forum for experimentalists and theorists to identify the challenges and refine the tools for high-precision tests of the Standard Model and searches for signals of new physics at Run II of the LHC. Topics to be discussed include: pinning down Standard Model corrections to key LHC processes; combining fixed-order QCD calculations with all-order resummations and parton showers; new developments in jet physics concerning jet substructure, associated jets and boosted je...

  12. Standard test methods for bend testing of metallic flat materials for spring applications involving static loading

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 This standard describes three test methods for determining the modulus of elasticity in bending and the bending strength of metallic strips or sheets intended for the use in flat springs: 1.1.1 Test Method A—a cantilever beam, 1.1.2 Test Method B—a three-point loaded beam (that is, a beam resting on two supports and centrally loaded), and 1.1.3 Test Method C—a four-point loaded beam (that is, a beam resting on two supports and loaded at two points equally spaced from each support). 1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. 6.1 This test me...

  13. Standard test method for wear testing with a pin-on-disk apparatus

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2005-01-01

    1.1 This test method covers a laboratory procedure for determining the wear of materials during sliding using a pin-on-disk apparatus. Materials are tested in pairs under nominally non-abrasive conditions. The principal areas of experimental attention in using this type of apparatus to measure wear are described. The coefficient of friction may also be determined. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  14. Standard test method for pin-type bearing test of metallic materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1984-01-01

    1.1 This test method covers a pin-type bearing test of metallic materials to determine bearing yield strength and bearing strength. Note 1—The presence of incidental lubricants on the bearing surfaces may significantly lower the value of bearing yield strength obtained by this method. 1.2 Units—The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  15. Standard test methods for elevated temperature tension tests of metallic materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 These test methods cover procedure and equipment for the determination of tensile strength, yield strength, elongation, and reduction of area of metallic materials at elevated temperatures. 1.2 Determination of modulus of elasticity and proportional limit are not included. 1.3 Tension tests under conditions of rapid heating or rapid strain rates are not included. 1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  16. Standard Test Method for Measuring Binocular Disparity in Transparent Parts

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This test method covers the amount of binocular disparity that is induced by transparent parts such as aircraft windscreens, canopies, HUD combining glasses, visors, or goggles. This test method may be applied to parts of any size, shape, or thickness, individually or in combination, so as to determine the contribution of each transparent part to the overall binocular disparity present in the total “viewing system” being used by a human operator. 1.2 This test method represents one of several techniques that are available for measuring binocular disparity, but is the only technique that yields a quantitative figure of merit that can be related to operator visual performance. 1.3 This test method employs apparatus currently being used in the measurement of optical angular deviation under Method F 801. 1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not con...

  17. Aligning English grammar testing with European language standards

    Directory of Open Access Journals (Sweden)

    Bodrič Radmila

    2015-01-01

    Full Text Available In recent years, foreign language testing has gained in significance with the advent of The Common European Framework of Reference for Languages (2001 (CEFR, a European language document which set comparable standards for learning, teaching and assessing foreign languages. The CEFR was used to set the research aim of this paper - testing grammar at level B2. The main aim of the research was to determine grammatical competence at level B2 and additional aims included: (a determining which particular areas of grammar need to be learned by students at level B2, (b formulating grammatical descriptors for each individual area of grammar, (c determining the test’s threshold level which would fulfil the criteria for grammatical competence at level B2, and (d determining the extent to which students have mastered the given areas. The pre-testing was followed by the main testing on the sample of 164 students in two secondary schools. The results indicated that the quantity and quality of grammatical competence was lower than expected: 47% of the population failed to fulfil the basic level of grammatical competence. The causes may be attributed to the factors of a subjective and objective nature. Level B2 is demanding qualitatively as well as quantitatively, regarding both the formal and the functional complexity and scope of language use, which requires intensive language production, high levels of motivation and sound working habits in order to master the given grammatical structures.

  18. Standard Test Method for Preparing Aircraft Cleaning Compounds, Liquid Type, Water Base, for Storage Stability Testing

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2002-01-01

    1.1 This test method covers the determination of the stability in storage, of liquid, water-base chemical cleaning compounds, used to clean the exterior surfaces of aircraft. 1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  19. BARTTest: Community-Standard Atmospheric Radiative-Transfer and Retrieval Tests

    Science.gov (United States)

    Harrington, Joseph; Himes, Michael D.; Cubillos, Patricio E.; Blecic, Jasmina; Challener, Ryan C.

    2018-01-01

    Atmospheric radiative transfer (RT) codes are used both to predict planetary and brown-dwarf spectra and in retrieval algorithms to infer atmospheric chemistry, clouds, and thermal structure from observations. Observational plans, theoretical models, and scientific results depend on the correctness of these calculations. Yet, the calculations are complex and the codes implementing them are often written without modern software-verification techniques. The community needs a suite of test calculations with analytically, numerically, or at least community-verified results. We therefore present the Bayesian Atmospheric Radiative Transfer Test Suite, or BARTTest. BARTTest has four categories of tests: analytically verified RT tests of simple atmospheres (single line in single layer, line blends, saturation, isothermal, multiple line-list combination, etc.), community-verified RT tests of complex atmospheres, synthetic retrieval tests on simulated data with known answers, and community-verified real-data retrieval tests.BARTTest is open-source software intended for community use and further development. It is available at https://github.com/ExOSPORTS/BARTTest. We propose this test suite as a standard for verifying atmospheric RT and retrieval codes, analogous to the Held-Suarez test for general circulation models. This work was supported by NASA Planetary Atmospheres grant NX12AI69G, NASA Astrophysics Data Analysis Program grant NNX13AF38G, and NASA Exoplanets Research Program grant NNX17AB62G.

  20. Standard Test Method for Hydrophobic Surface Films by the Water-Break Test

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2002-01-01

    1.1 This test method covers the detection of the presence of hydrophobic (nonwetting) films on surfaces and the presence of hydrophobic organic materials in processing ambients. When properly conducted, the test will enable detection of molecular layers of hydrophobic organic contaminants. On very rough or porous surfaces, the sensitivity of the test may be significantly decreased. 1.2 The values stated in SI units are to be regarded as the standard. The inch-pound values given in parentheses are for information only. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  1. Standard Test Method for Hydrophobic Surface Films by the Atomizer Test

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1965-01-01

    1.1 This test method covers the detection of the presence of hydrophobic (nonwetting) films on surfaces and the presence of hydrophobic organic materials in processing ambients. When properly conducted, the test will enable detection of fractional molecular layers of hydrophobic organic contaminants. On very rough or porous surfaces the sensitivity of the test may be significantly decreased. 1.2 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are for information only. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  2. Standard test method for tension testing of structural alloys in liquid helium

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This test method describes procedures for the tension testing of structural alloys in liquid helium. The format is similar to that of other ASTM tension test standards, but the contents include modifications for cryogenic testing which requires special apparatus, smaller specimens, and concern for serrated yielding, adiabatic heating, and strain-rate effects. 1.2 To conduct a tension test by this standard, the specimen in a cryostat is fully submerged in normal liquid helium (He I) and tested using crosshead displacement control at a nominal strain rate of 10−3 s−1 or less. Tests using force control or high strain rates are not considered. 1.3 This standard specifies methods for the measurement of yield strength, tensile strength, elongation, and reduction of area. The determination of the elastic modulus is treated in Test Method E 111. Note 1—The boiling point of normal liquid helium (He I) at sea level is 4.2 K (−269°C or −452.1°F or 7.6°R). It decreases with geographic elevation and is...

  3. Standard test method for guided bend test for ductility of welds

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2002-01-01

    1.1 This test method covers a guided bend test for the determination of soundness and ductility of welds in ferrous and nonferrous products. Defects, not shown by X rays, may appear in the surface of a specimen when it is subjected to progressive localized overstressing. This guided bend test has been developed primarily for plates and is not intended to be substituted for other methods of bend testing. 1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. Note 1—For additional information see Terminology E 6, and American Welding Society Standard D 1.1. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  4. Draft forces prediction model for standard single tines by using principles of soil mechanics and soil profile evaluation

    Directory of Open Access Journals (Sweden)

    Amer Khalid Ahmed Al-Neama

    2017-06-01

    Full Text Available This paper explains a model to predict the draft force acting on varying standard single tines by using principles of soil mechanics and soil profile evaluation. Draft force (Fd measurements were made with four standard single tines comprising Heavy Duty, Double Heart, Double Heart with Wings and Duck Foot. Tine widths were 6.5, 13.5, 45 and 40 cm, respectively. The test was conducted in a soil bin with sandy loam soil. The effects of forward speeds and working depths on draft forces were investigated under controlled lab conditions. Results were evaluated based on a prediction model. A good correlation between measured and predicted Fd values for all tines with an average absolute variation less than 15 % was found.

  5. US Department of Energy DOE Nevada Operations Office, Nevada Test Site: Underground safety and health standards

    Energy Technology Data Exchange (ETDEWEB)

    1993-05-01

    The Nevada Test Site Underground Safety and Health Standards Working Group was formed at the direction of John D. Stewart, Director, Nevada Test Site Office in April, 1990. The objective of the Working Group was to compile a safety and health standard from the California Tunnel Safety Orders and OSHA for the underground operations at the NTS, (excluding Yucca Mountain). These standards are called the NTS U/G Safety and Health Standards. The Working Group submits these standards as a RECOMMENDATION to the Director, NTSO. Although the Working Group considers these standards to be the most integrated and comprehensive standards that could be developed for NTS Underground Operations, the intent is not to supersede or replace any relevant DOE orders. Rather the intent is to collate the multiple safety and health references contained in DOE Order 5480.4 that have applicability to NTS Underground Operations into a single safety and heath standard to be used in the underground operations at the NTS. Each portion of the standard was included only after careful consideration by the Working Group and is judged to be both effective and appropriate. The specific methods and rationale used by the Working Group are outlined as follows: The letter from DOE/HQ, dated September 28, 1990 cited OSHA and the CTSO as the safety and health codes applicable to underground operations at the NTS. These mandated codes were each originally developed to be comprehensive, i.e., all underground operations of a particular type (e.g., tunnels in the case of the CTSO) were intended to be adequately regulated by the appropriate code. However, this is not true; the Working Group found extensive and confusing overlap in the codes in numerous areas. Other subjects and activities were addressed by the various codes in cursory fashion or not at all.

  6. US Department of Energy DOE Nevada Operations Office, Nevada Test Site: Underground safety and health standards

    International Nuclear Information System (INIS)

    1993-05-01

    The Nevada Test Site Underground Safety and Health Standards Working Group was formed at the direction of John D. Stewart, Director, Nevada Test Site Office in April, 1990. The objective of the Working Group was to compile a safety and health standard from the California Tunnel Safety Orders and OSHA for the underground operations at the NTS, (excluding Yucca Mountain). These standards are called the NTS U/G Safety and Health Standards. The Working Group submits these standards as a RECOMMENDATION to the Director, NTSO. Although the Working Group considers these standards to be the most integrated and comprehensive standards that could be developed for NTS Underground Operations, the intent is not to supersede or replace any relevant DOE orders. Rather the intent is to collate the multiple safety and health references contained in DOE Order 5480.4 that have applicability to NTS Underground Operations into a single safety and heath standard to be used in the underground operations at the NTS. Each portion of the standard was included only after careful consideration by the Working Group and is judged to be both effective and appropriate. The specific methods and rationale used by the Working Group are outlined as follows: The letter from DOE/HQ, dated September 28, 1990 cited OSHA and the CTSO as the safety and health codes applicable to underground operations at the NTS. These mandated codes were each originally developed to be comprehensive, i.e., all underground operations of a particular type (e.g., tunnels in the case of the CTSO) were intended to be adequately regulated by the appropriate code. However, this is not true; the Working Group found extensive and confusing overlap in the codes in numerous areas. Other subjects and activities were addressed by the various codes in cursory fashion or not at all

  7. Standard test method for K-R curve determination

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This test method covers the determination of the resistance to fracture of metallic materials under Mode I loading at static rates using either of the following notched and precracked specimens: the middle-cracked tension M(T) specimen or the compact tension C(T) specimen. A K-R curve is a continuous record of toughness development (resistance to crack extension) in terms of KR plotted against crack extension in the specimen as a crack is driven under an increasing stress intensity factor, K. 1.2 Materials that can be tested for K-R curve development are not limited by strength, thickness, or toughness, so long as specimens are of sufficient size to remain predominantly elastic to the effective crack extension value of interest. 1.3 Specimens of standard proportions are required, but size is variable, to be adjusted for yield strength and toughness of the materials. 1.4 Only two of the many possible specimen types that could be used to develop K-R curves are covered in this method. 1.5 The test is app...

  8. Multiple transfer standard for calibration and characterization of test setups for LED lamps and luminaires in industry

    Science.gov (United States)

    Sperling, A.; Meyer, M.; Pendsa, S.; Jordan, W.; Revtova, E.; Poikonen, T.; Renoux, D.; Blattner, P.

    2018-04-01

    Proper characterization of test setups used in industry for testing and traceable measurement of lighting devices by the substitution method is an important task. According to new standards for testing LED lamps, luminaires and modules, uncertainty budgets are requested because in many cases the properties of the device under test differ from the transfer standard used, which may cause significant errors, for example if a LED-based lamp is tested or calibrated in an integrating sphere which was calibrated with a tungsten lamp. This paper introduces a multiple transfer standard, which was designed not only to transfer a single calibration value (e.g. luminous flux) but also to characterize test setups used for LED measurements with additional provided and calibrated output features to enable the application of the new standards.

  9. Potential of electric quadrupole transitions in radium isotopes for single-ion optical frequency standards

    NARCIS (Netherlands)

    Versolato, O. O.; Wansbeek, L. W.; Jungmann, K.; Timmermans, R. G. E.; Willmann, L.; Wilschut, H. W.

    2011-01-01

    We explore the potential of the electric quadrupole transitions 7s (2)S(1/2)-(6)d (2)D(3/2), 6d (2)D(5/2) in radium isotopes as single-ion optical frequency standards. The frequency shifts of the clock transitions due to external fields and the corresponding uncertainties are calculated. Several

  10. Randomization and Data-Analysis Items in Quality Standards for Single-Case Experimental Studies

    Science.gov (United States)

    Heyvaert, Mieke; Wendt, Oliver; Van den Noortgate, Wim; Onghena, Patrick

    2015-01-01

    Reporting standards and critical appraisal tools serve as beacons for researchers, reviewers, and research consumers. Parallel to existing guidelines for researchers to report and evaluate group-comparison studies, single-case experimental (SCE) researchers are in need of guidelines for reporting and evaluating SCE studies. A systematic search was…

  11. 32 CFR Attachment B to Subpart B... - Standard B-Single Scope Background Investigation (SSBI)

    Science.gov (United States)

    2010-07-01

    ... 32 National Defense 1 2010-07-01 2010-07-01 false Standard B-Single Scope Background Investigation (SSBI) B Attachment B to Subpart B of Part 147 National Defense Department of Defense OFFICE OF THE SECRETARY OF DEFENSE PERSONNEL, MILITARY AND CIVILIAN ADJUDICATIVE GUIDELINES FOR DETERMINING ELIGIBILITY FOR ACCESS TO CLASSIFIED INFORMATION...

  12. The Weighted Airman Promotion System: Standardizing Test Scores

    Science.gov (United States)

    2008-01-01

    u th o ri ze d Top 3/E6 ratio, inventory 1401206040 100 70 130 5R 2F 2G 3N 2M 2A 4J 4C 4P 4T 4B 1W 2T 3P 1T 4A 2S 5J 1A 1S1C 6F 4N 7S 4R 4E 1N 3A 3V...Costs If the Air Force decided to standardize test scores, there would be three basic types of costs: implementation costs, marketing costs, and...analytical costs for this more deliberate approach could be three to four person-years. It would be appropriate for the Air Force to market any

  13. Comparison of standard PCR/cloning to single genome sequencing for analysis of HIV-1 populations.

    Science.gov (United States)

    Jordan, Michael R; Kearney, Mary; Palmer, Sarah; Shao, Wei; Maldarelli, Frank; Coakley, Eoin P; Chappey, Colombe; Wanke, Christine; Coffin, John M

    2010-09-01

    To compare standard PCR/cloning and single genome sequencing (SGS) in their ability to reflect actual intra-patient polymorphism of HIV-1 populations, a total of 530 HIV-1 pro-pol sequences obtained by both sequencing techniques from a set of 17 ART naïve patient specimens was analyzed. For each specimen, 12 and 15 sequences, on average, were characterized by the two techniques. Using phylogenetic analysis, tests for panmixia and entropy, and Bland-Altman plots, no difference in population structure or genetic diversity was shown in 14 of the 17 subjects. Evidence of sampling bias by the presence of subsets of identical sequences was found by either method. Overall, the study shows that neither method was more biased than the other, and providing that an adequate number of PCR templates is analyzed, and that the bulk sequencing captures the diversity of the viral population, either method is likely to provide a similar measure of population diversity. Copyright 2010 Elsevier B.V. All rights reserved.

  14. Setting Passing Scores on Passage-Based Tests: A Comparison of Traditional and Single-Passage Bookmark Methods

    Science.gov (United States)

    Skaggs, Gary; Hein, Serge F.; Awuor, Risper

    2007-01-01

    In this study, a variation of the bookmark standard setting procedure for passage-based tests is proposed in which separate ordered item booklets are created for the items associated with each passage. This variation is compared to the traditional bookmark procedure for a fifth-grade reading test. The results showed that the single-passage…

  15. Underwater noise from geotechnical drilling and standard penetration testing.

    Science.gov (United States)

    Erbe, Christine; McPherson, Craig

    2017-09-01

    Geotechnical site investigations prior to marine construction typically involve shallow, small-core drilling and standard penetration testing (SPT), during which a small tube is hammered into the ground at the bottom of the borehole. Drilling (120 kW, 83 mm diameter drillbit, 1500 rpm, 16-17 m drill depth in sand and mudstone) and SPT (50 mm diameter test tube, 15 mm wall thickness, 100 kg hammer, 1 m drop height) by a jack-up rig in 7-13 m of water were recorded with a drifting hydrophone at 10-50 m range. Source levels were 142-145 dB re 1 μPa rms @ 1 m (30-2000 Hz) for drilling and 151-160 dB re 1 μPa 2 s @ 1 m (20-24 000 Hz) for SPT.

  16. Working on a Standard Joint Unit: A pilot test.

    Science.gov (United States)

    Casajuana, Cristina; López-Pelayo, Hugo; Mercedes Balcells, María; Miquel, Laia; Teixidó, Lídia; Colom, Joan; Gual, Antoni

    2017-09-29

    Assessing cannabis consumption remains complex due to no reliable registration systems. We tested the likelihood of establishing a Standard Joint Unit (SJU) which considers the main cannabinoids with implication on health through a naturalistic approach.  Methodology. Pilot study with current cannabis users of four areas of Barcelona: universities, nightclubs, out-patient mental health service, and cannabis associations. We designed and administered a questionnaire on cannabis use-patterns and determined the willingness to donate a joint for analysis. Descriptive statistics were used to analyze the data. Forty volunteers answered the questionnaire (response rate 95%); most of them were men (72.5%) and young adults (median age 24.5 years; IQR 8.75 years) who consume daily or nearly daily (70%). Most participants consume marihuana (85%) and roll their joints with a median of 0.25 gr of marihuana. Two out of three (67.5%) stated they were willing to donate a joint. Obtaining an SJU with the planned methodology has proved to be feasible. Pre-testing resulted in an improvement of the questionnaire and retribution to incentivize donations. Establishing an SJU is essential to improve our knowledge on cannabis-related outcomes.

  17. Pilot test of ANSI draft standard N13.29 environmental dosimetry -- Performance criteria for testing

    Energy Technology Data Exchange (ETDEWEB)

    Klemic, G.; Shebell, P.; Monetti, M.; Raccah, F. [Dept. of Energy, New York, NY (United States). Environmental Measurement Lab.; Shobe, J.; Lamperti, P.; Soares, C. [National Inst. of Standards and Technology, Gaithersburg, MD (United States); Sengupta, S. [Brookhaven National Lab., Upton, NY (United States)

    1998-09-01

    American National Standards Institute Draft N13.29 describes performance tests for environmental radiation dosimetry providers. If approved it would be the first step toward applying the types of performance testing now required in personnel dosimetry to environmental radiation monitoring. The objective of this study was to pilot test the draft standard, before it undergoes final balloting, on a small group of dosimetry providers that were selected to provide a mix of facility types, thermoluminescent dosimeter designs and monitoring program applications. The first phase of the pilot test involved exposing dosimeters to laboratory photon, beta, and x-ray sources at routine and accident dose levels. In the second phase, dosimeters were subjected to ninety days of simulated environmental conditions in an environmental chamber that cycled through extremes of temperature and humidity. Two out of seven participants passed all categories of the laboratory testing phase, and all seven passed the environmental test phase. While some relatively minor deficiencies were uncovered in the course of the pilot test, the results show that draft N13.29 describes useful tests that could be appropriate for environmental dosimetry providers. An appendix to this report contains recommendations that should be addressed by the N13.29 working group before draft N13.29 is submitted for balloting.

  18. Simple test system for single molecule recognition force microscopy

    International Nuclear Information System (INIS)

    Riener, Christian K.; Stroh, Cordula M.; Ebner, Andreas; Klampfl, Christian; Gall, Alex A.; Romanin, Christoph; Lyubchenko, Yuri L.; Hinterdorfer, Peter; Gruber, Hermann J.

    2003-01-01

    We have established an easy-to-use test system for detecting receptor-ligand interactions on the single molecule level using atomic force microscopy (AFM). For this, avidin-biotin, probably the best characterized receptor-ligand pair, was chosen. AFM sensors were prepared containing tethered biotin molecules at sufficiently low surface concentrations appropriate for single molecule studies. A biotin tether, consisting of a 6 nm poly(ethylene glycol) (PEG) chain and a functional succinimide group at the other end, was newly synthesized and covalently coupled to amine-functionalized AFM tips. In particular, PEG 800 diamine was glutarylated, the mono-adduct NH 2 -PEG-COOH was isolated by ion exchange chromatography and reacted with biotin succinimidylester to give biotin-PEG-COOH which was then activated as N-hydroxysuccinimide (NHS) ester to give the biotin-PEG-NHS conjugate which was coupled to the aminofunctionalized AFM tip. The motional freedom provided by PEG allows for free rotation of the biotin molecule on the AFM sensor and for specific binding to avidin which had been adsorbed to mica surfaces via electrostatic interactions. Specific avidin-biotin recognition events were discriminated from nonspecific tip-mica adhesion by their typical unbinding force (∼40 pN at 1.4 nN/s loading rate), unbinding length (<13 nm), the characteristic nonlinear force-distance relation of the PEG linker, and by specific block with excess of free d-biotin. The convenience of the test system allowed to evaluate, and compare, different methods and conditions of tip aminofunctionalization with respect to specific binding and nonspecific adhesion. It is concluded that this system is well suited as calibration or start-up kit for single molecule recognition force microscopy

  19. Inter-rater reliability of three standardized functional tests in patients with low back pain

    Science.gov (United States)

    Tidstrand, Johan; Horneij, Eva

    2009-01-01

    Background Of all patients with low back pain, 85% are diagnosed as "non-specific lumbar pain". Lumbar instability has been described as one specific diagnosis which several authors have described as delayed muscular responses, impaired postural control as well as impaired muscular coordination among these patients. This has mostly been measured and evaluated in a laboratory setting. There are few standardized and evaluated functional tests, examining functional muscular coordination which are also applicable in the non-laboratory setting. In ordinary clinical work, tests of functional muscular coordination should be easy to apply. The aim of this present study was to therefore standardize and examine the inter-rater reliability of three functional tests of muscular functional coordination of the lumbar spine in patients with low back pain. Methods Nineteen consecutive individuals, ten men and nine women were included. (Mean age 42 years, SD ± 12 yrs). Two independent examiners assessed three tests: "single limb stance", "sitting on a Bobath ball with one leg lifted" and "unilateral pelvic lift" on the same occasion. The standardization procedure took altered positions of the spine or pelvis and compensatory movements of the free extremities into account. The inter-rater reliability was analyzed by Cohen's kappa coefficient (κ) and by percentage agreement. Results The inter-rater reliability for the right and the left leg respectively was: for the single limb stance very good (κ: 0.88–1.0), for sitting on a Bobath ball good (κ: 0.79) and very good (κ: 0.88) and for the unilateral pelvic lift: good (κ: 0.61) and moderate (κ: 0.47). Conclusion The present study showed good to very good inter-rater reliability for two standardized tests, that is, the single-limb stance and sitting on a Bobath-ball with one leg lifted. Inter-rater reliability for the unilateral pelvic lift test was moderate to good. Validation of the tests in their ability to evaluate lumbar

  20. Inter-rater reliability of three standardized functional tests in patients with low back pain

    Directory of Open Access Journals (Sweden)

    Tidstrand Johan

    2009-06-01

    Full Text Available Abstract Background Of all patients with low back pain, 85% are diagnosed as "non-specific lumbar pain". Lumbar instability has been described as one specific diagnosis which several authors have described as delayed muscular responses, impaired postural control as well as impaired muscular coordination among these patients. This has mostly been measured and evaluated in a laboratory setting. There are few standardized and evaluated functional tests, examining functional muscular coordination which are also applicable in the non-laboratory setting. In ordinary clinical work, tests of functional muscular coordination should be easy to apply. The aim of this present study was to therefore standardize and examine the inter-rater reliability of three functional tests of muscular functional coordination of the lumbar spine in patients with low back pain. Methods Nineteen consecutive individuals, ten men and nine women were included. (Mean age 42 years, SD ± 12 yrs. Two independent examiners assessed three tests: "single limb stance", "sitting on a Bobath ball with one leg lifted" and "unilateral pelvic lift" on the same occasion. The standardization procedure took altered positions of the spine or pelvis and compensatory movements of the free extremities into account. The inter-rater reliability was analyzed by Cohen's kappa coefficient (κ and by percentage agreement. Results The inter-rater reliability for the right and the left leg respectively was: for the single limb stance very good (κ: 0.88–1.0, for sitting on a Bobath ball good (κ: 0.79 and very good (κ: 0.88 and for the unilateral pelvic lift: good (κ: 0.61 and moderate (κ: 0.47. Conclusion The present study showed good to very good inter-rater reliability for two standardized tests, that is, the single-limb stance and sitting on a Bobath-ball with one leg lifted. Inter-rater reliability for the unilateral pelvic lift test was moderate to good. Validation of the tests in their

  1. Development of the Test Of Astronomy STandards (TOAST) Assessment Instrument

    Science.gov (United States)

    Slater, Timothy F.; Slater, S. J.

    2008-05-01

    Considerable effort in the astronomy education research (AER) community over the past several years has focused on developing assessment tools in the form of multiple-choice conceptual diagnostics and content knowledge surveys. This has been critically important in advancing the AER discipline so that researchers could establish the initial knowledge state of students as well as to attempt measure some of the impacts of innovative instructional interventions. Unfortunately, few of the existing instruments were constructed upon a solid list of clearly articulated and widely agreed upon learning objectives. This was not done in oversight, but rather as a result of the relative youth of AER as a discipline. Now that several important science education reform documents exist and are generally accepted by the AER community, we are in a position to develop, validate, and disseminate a new assessment instrument which is tightly aligned to the consensus learning goals stated by the American Astronomical Society - Chair's Conference on ASTRO 101, the American Association of the Advancement of Science's Project 2061 Benchmarks, and the National Research Council's National Science Education Standards. In response, researchers from the Cognition in Astronomy, Physics and Earth sciences Research (CAPER) Team at the University of Wyoming's Science & Math Teaching Center (UWYO SMTC) have designed a criterion-referenced assessment tool, called the Test Of Astronomy STandards (TOAST). Through iterative development, this instrument has a high degree of reliability and validity for instructors and researchers needing information on students’ initial knowledge state at the beginning of a course and can be used, in aggregate, to help measure the impact of course-length duration instructional strategies for courses with learning goals tightly aligned to the consensus goals of our community.

  2. Detectability of single and plural flaws by ultrasonic testing

    International Nuclear Information System (INIS)

    Iida, K.

    1985-01-01

    An outline and up-to-date test results of an eight year project of proving tests on the effectiveness of in-service inspection is described in the first part of the present paper. Effects on the detectability of such testing parameters as refraction angle, thickness of stainless steel cladding, inspectors, standard flaws in reference specimens, stress state subjected to defects are discussed. This is followed by a discussion of detection reproducibility, resolution and accuracy of inspected size of a defects. The latter part of the paper deals with up-to-date results of tests on resolution and shape determination of propagating adjacent and co-linear fatigue cracks by ultrasonic examination. It was found that real lengths of fatigue crack and EDM surface notch will be roughly estimated by 12 dB and 8 dB down methods, respectively. It is also concluded that the 10 dB down method is available for estimation of the inside distance of two co-linear surface cracks

  3. Refractory Metal Heat Pipe Life Test - Test Plan and Standard Operating Procedures

    Science.gov (United States)

    Martin, J. J.; Reid, R. S.

    2010-01-01

    Refractory metal heat pipes developed during this project shall be subjected to various operating conditions to evaluate life-limiting corrosion factors. To accomplish this objective, various parameters shall be investigated, including the effect of temperature and mass fluence on long-term corrosion rate. The test series will begin with a performance test of one module to evaluate its performance and to establish the temperature and power settings for the remaining modules. The performance test will be followed by round-the-clock testing of 16 heat pipes. All heat pipes shall be nondestructively inspected at 6-month intervals. At longer intervals, specific modules will be destructively evaluated. Both the nondestructive and destructive evaluations shall be coordinated with Los Alamos National Laboratory. During the processing, setup, and testing of the heat pipes, standard operating procedures shall be developed. Initial procedures are listed here and, as hardware is developed, will be updated, incorporating findings and lessons learned.

  4. The OSU Hydro-Mechanical Fuel Test Facility: Standard Fuel Element Testing

    Energy Technology Data Exchange (ETDEWEB)

    Wade R. Marcum; Brian G. Woods; Ann Marie Phillips; Richard G. Ambrosek; James D. Wiest; Daniel M. Wachs

    2001-10-01

    Oregon State University (OSU) and the Idaho National Laboratory (INL) are currently collaborating on a test program which entails hydro-mechanical testing of a generic plate type fuel element, or standard fuel element (SFE), for the purpose of qualitatively demonstrating mechanical integrity of uranium-molybdenum monolithic plates as compared to that of uranium aluminum dispersion, and aluminum fuel plates due to hydraulic forces. This test program supports ongoing work conducted for/by the fuel development program and will take place at OSU in the Hydro-Mechanical Fuel Test Facility (HMFTF). Discussion of a preliminary test matrix, SFE design, measurement and instrumentation techniques, and facility description are detailed in this paper.

  5. Touch sensitivity with sterile standard surgical gloves and single-use protective gloves.

    Science.gov (United States)

    Tiefenthaler, W; Gimpl, S; Wechselberger, G; Benzer, A

    2006-10-01

    The purpose of this study was to evaluate touch sensitivity and static two-point discrimination of the dominant index and middle finger in 20 anaesthetists wearing no gloves, single-use protective gloves or sterile standard surgical gloves. Semmes-Weinstein filaments were used to measure cutaneous pressure thresholds, and a Two-Point-Discriminator to estimate static two-point discrimination. Wearing gloves significantly reduced touch sensitivity (p gloves. The results of our study suggest that the additional cost of sterile standard surgical gloves can not be justified in terms of touch sensitivity.

  6. Single Stage Contactor Testing Of The Next Generation Solvent Blend

    Energy Technology Data Exchange (ETDEWEB)

    Herman, D. T.; Peters, T. B.; Duignan, M. R.; Williams, M. R.; Poirier, M. R.; Brass, E. A.; Garrison, A. G.; Ketusky, E. T.

    2014-01-06

    The Modular Caustic Side Solvent Extraction (CSSX) Unit (MCU) facility at the Savannah River Site (SRS) is actively pursuing the transition from the current BOBCalixC6 based solvent to the Next Generation Solvent (NGS)-MCU solvent to increase the cesium decontamination factor. To support this integration of NGS into the MCU facility the Savannah River National Laboratory (SRNL) performed testing of a blend of the NGS (MaxCalix based solvent) with the current solvent (BOBCalixC6 based solvent) for the removal of cesium (Cs) from the liquid salt waste stream. This testing utilized a blend of BOBCalixC6 based solvent and the NGS with the new extractant, MaxCalix, as well as a new suppressor, tris(3,7dimethyloctyl) guanidine. Single stage tests were conducted using the full size V-05 and V-10 liquid-to-liquid centrifugal contactors installed at SRNL. These tests were designed to determine the mass transfer and hydraulic characteristics with the NGS solvent blended with the projected heel of the BOBCalixC6 based solvent that will exist in MCU at time of transition. The test program evaluated the amount of organic carryover and the droplet size of the organic carryover phases using several analytical methods. The results indicate that hydraulically, the NGS solvent performed hydraulically similar to the current solvent which was expected. For the organic carryover 93% of the solvent is predicted to be recovered from the stripping operation and 96% from the extraction operation. As for the mass transfer, the NGS solvent significantly improved the cesium DF by at least an order of magnitude when extrapolating the One-stage results to actual Seven-stage extraction operation with a stage efficiency of 95%.

  7. Standardized Testing Program for Solid-State Hydrogen Storage Technologies

    Energy Technology Data Exchange (ETDEWEB)

    Miller, Michael A. [Southwest Research Institute; Page, Richard A. [Southwest Research Institute

    2012-07-30

    In the US and abroad, major research and development initiatives toward establishing a hydrogen-based transportation infrastructure have been undertaken, encompassing key technological challenges in hydrogen production and delivery, fuel cells, and hydrogen storage. However, the principal obstacle to the implementation of a safe, low-pressure hydrogen fueling system for fuel-cell powered vehicles remains storage under conditions of near-ambient temperature and moderate pressure. The choices for viable hydrogen storage systems at the present time are limited to compressed gas storage tanks, cryogenic liquid hydrogen storage tanks, chemical hydrogen storage, and hydrogen absorbed or adsorbed in a solid-state material (a.k.a. solid-state storage). Solid-state hydrogen storage may offer overriding benefits in terms of storage capacity, kinetics and, most importantly, safety.The fervor among the research community to develop novel storage materials had, in many instances, the unfortunate consequence of making erroneous, if not wild, claims on the reported storage capacities achievable in such materials, to the extent that the potential viability of emerging materials was difficult to assess. This problem led to a widespread need to establish a capability to accurately and independently assess the storage behavior of a wide array of different classes of solid-state storage materials, employing qualified methods, thus allowing development efforts to focus on those materials that showed the most promise. However, standard guidelines, dedicated facilities, or certification programs specifically aimed at testing and assessing the performance, safety, and life cycle of these emergent materials had not been established. To address the stated need, the Testing Laboratory for Solid-State Hydrogen Storage Technologies was commissioned as a national-level focal point for evaluating new materials emerging from the designated Materials Centers of Excellence (MCoE) according to

  8. Predicting a single HIV drug resistance measure from three international interpretation gold standards.

    Science.gov (United States)

    Yashik, Singh; Maurice, Mars

    2012-07-01

    To investigate the possibility of combining the interpretation of three gold standard interpretation algorithms using weighted heuristics in order to produce a single resistance measure. The outputs of HIVdb, Rega, ANRS were combined to obtain a single resistance profile using the equally weighted voting algorithm, accuracy based weighing voting algorithm and the Bayesian based weighted voting algorithm techniques. The Bayesian based voting combination increased the accuracy of the resistance profile prediction compared to phenotype, from 58% to 69%. The equal weighted voting algorithm and the accuracy based algorithm both increased the prediction accuracy to 60%. From the result obtained it is evident that combining the gold standard interpretation algorithms may increase the predictive ability of the individual interpretation algorithms. Copyright © 2012 Hainan Medical College. Published by Elsevier B.V. All rights reserved.

  9. Laboratory testing on infiltration in single synthetic fractures

    Science.gov (United States)

    Cherubini, Claudia; Pastore, Nicola; Li, Jiawei; Giasi, Concetta I.; Li, Ling

    2017-04-01

    An understanding of infiltration phenomena in unsaturated rock fractures is extremely important in many branches of engineering for numerous reasons. Sectors such as the oil, gas and water industries are regularly interacting with water seepage through rock fractures, yet the understanding of the mechanics and behaviour associated with this sort of flow is still incomplete. An apparatus has been set up to test infiltration in single synthetic fractures in both dry and wet conditions. To simulate the two fracture planes, concrete fractures have been moulded from 3D printed fractures with varying geometrical configurations, in order to analyse the influence of aperture and roughness on infiltration. Water flows through the single fractures by means of a hydraulic system composed by an upstream and a downstream reservoir, the latter being subdivided into five equal sections in order to measure the flow rate in each part to detect zones of preferential flow. The fractures have been set at various angles of inclination to investigate the effect of this parameter on infiltration dynamics. The results obtained identified that altering certain fracture parameters and conditions produces relevant effects on the infiltration process through the fractures. The main variables influencing the formation of preferential flow are: the inclination angle of the fracture, the saturation level of the fracture and the mismatch wavelength of the fracture.

  10. Testing the single degenerate channel for supernova Ia

    Science.gov (United States)

    Parsons, Steven

    2014-10-01

    The progenitors of supernova Ia are close binaries containing white dwarfs. Of crucial importance to the evolution of these systems is how much material the white dwarf can stably accrete and hence grow in mass. This occurs during a short-lived intense phase of mass transfer known as the super soft source (SSS) phase. The short duration of this phase and large extinction to soft X-rays means that only a handful are known in our Galaxy. Far more can be learned from the underlying SSS progenitor population of close white dwarf plus FGK type binaries. Unfortunately, these systems are hard to find since the main-sequence stars completely outshine the white dwarfs at optical wavelengths. Because of this, there are currently no known close white dwarf binaries with F, G or early K type companions, making it impossible to determine the contribution of the single degenerate channel towards supernova Ia. Using the GALEX and RAVE surveys we have now identified the first large sample of FGK stars with UV excesses, a fraction of which are these illusive, close systems. Following an intense ground based spectroscopic investigation of these systems, we have identified 5 definite close binaries, with periods of less than a few days. Here we apply for COS spectroscopic observations to measure the mass and temperature of the white dwarfs in order to determine the future evolution of these systems. This will provide a crucial test for the single degenerate channel towards supernova Ia.

  11. Crystal plasticity study of single crystal tungsten by indentation tests

    International Nuclear Information System (INIS)

    Yao, Weizhi

    2012-01-01

    Owing to its favorable material properties, tungsten (W) has been studied as a plasma-facing material in fusion reactors. Experiments on W heating in plasma sources and electron beam facilities have shown an intense micro-crack formation at the heated surface and sub-surface. The cracks go deep inside the irradiated sample, and often large distorted areas caused by local plastic deformation are present around the cracks. To interpret the crack-induced microscopic damage evolution process in W, one needs firstly to understand its plasticity on a single grain level, which is referred to as crystal plasticity. In this thesis, the crystal plasticity of single crystal tungsten (SCW) has been studied by spherical and Berkovich indentation tests and the finite element method with a crystal plasticity model. Appropriate values of the material parameters included in the crystal plasticity model are determined by fitting measured load-displacement curves and pile-up profiles with simulated counterparts for spherical indentation. The numerical simulations reveal excellent agreement with experiment. While the load-displacement curves and the deduced indentation hardness exhibit little sensitivity to the indented plane at small indentation depths, the orientation of slip directions within the crystals governs the development of deformation hillocks at the surface. It is found that several factors like friction, indentation depth, active slip systems, misoriented crystal orientation, misoriented sample surface and azimuthal orientation of the indenter can affect the indentation behavior of SCW. The Berkovich indentation test was also used to study the crystal plasticity of SCW after deuterium irradiation. The critical load (pop-in load) for triggering plastic deformation under the indenter is found to depend on the crystallographic orientation. The pop-in loads decrease dramatically after deuterium plasma irradiation for all three investigated crystallographic planes.

  12. [Precautions of physical performance requirements and test methods during product standard drafting process of medical devices].

    Science.gov (United States)

    Song, Jin-Zi; Wan, Min; Xu, Hui; Yao, Xiu-Jun; Zhang, Bo; Wang, Jin-Hong

    2009-09-01

    The major idea of this article is to discuss standardization and normalization for the product standard of medical devices. Analyze the problem related to the physical performance requirements and test methods during product standard drafting process and make corresponding suggestions.

  13. First steps towards fuel cells testing harmonisation: Procedures and parameters for single cell performance evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Lunghi, P. [Department of Industrial Engineering, University of Perugia, Via Duranti 93, Perugia (Italy); Ubertini, S. [Department of Mechanical Engineering, University of Rome ' ' Tor Vergata' ' , Via di Torvergata, 110, Rome (Italy)

    2004-01-01

    The great interest in Fuel Cell Systems, combined with the innovation of the device itself, has led to a huge developmental effort to make the steps necessary for future FC plant commissioning. The clearest and most effective way to evaluate the performance of a fuel cell is to measure it directly and, since few fuel cell test rigs are available at the moment, standard experimental procedures have not been realized so far. Our research group is currently performing single cell testing at the University of Perugia fuel cell laboratory and particular emphasis has been put on the definition of procedures and the testing of parameterisation. The work team strongly believes that this is the key to effective system testing and reliable performance evaluation. In this work, the test parameterisation developed by the team, and the resulting advanced control procedure used for a single MCFC experimental characterization are presented. Efforts have been dedicated to obtain some relevant non-dimensional parameters to allow an easy understanding of the results and quick comparisons with other tests under different operating conditions, or with results obtained on different cells eventually tested in different laboratories. The authors strongly emphasise this topic to avoid the data that developers and research institutions collect being of no practical use due to a lack of shared rules. (Abstract Copyright [2003], Wiley Periodicals, Inc.)

  14. Effectiveness Analysis of a Non-Destructive Single Event Burnout Test Methodology

    CERN Document Server

    Oser, P; Spiezia, G; Fadakis, E; Foucard, G; Peronnard, P; Masi, A; Gaillard, R

    2014-01-01

    It is essential to characterize power MosFETs regarding their tolerance to destructive Single Event Burnouts (SEB). Therefore, several non-destructive test methods have been developed to evaluate the SEB cross-section of power devices. A power MosFET has been evaluated using a test circuit, designed according to standard non-destructive test methods discussed in the literature. Guidelines suggest a prior adaptation of auxiliary components to the device sensitivity before the radiation test. With the first value chosen for the de-coupling capacitor, the external component initiated destructive events and affected the evaluation of the cross-section. As a result, the influence of auxiliary components on the device cross-section was studied. This paper presents the obtained experimental results, supported by SPICE simulations, to evaluate and discuss how the circuit effectiveness depends on the external components.

  15. Energy and economic evaluation of the single-family residential building energy performance standards

    Energy Technology Data Exchange (ETDEWEB)

    O' Neal, D.L.; Jones, J.L.

    1981-11-01

    The Energy Production and Conservation Act (EPCA) of 1976 mandated the setting of building energy performance standards (BEPS) for all newly constructed buildings. One of the classes of buildings included in EPCA is single-family residences. These standards cover the energy used for space heating, air conditioning, and water heating. This report describes the evaluation of direct energy and economic impacts of three proposed levels of single-family BEPS: lenient, mid, and strict. The lenient level is the least stringent in requiring improvements in eneryperformance of residence while the strict is the most stringent. Each of the levels and the method of developing them are also described. The ORNL residential energy model is used to calculate energy savings and economic impacts of BEPS to the nation. The model is also used to estimate the sensitivity of the results to several exogenous variables: projected fuel prices, baseline energy codes, capital csts, short-run price elasticities, and discount rates. The Net Present Value (NPV) and cumulative energy savings from 1980 to 2020 are the two measures used to compare the standards. Both the lenient and mid level standards provide a positive economic benefit to the country of 1.24 and 2.58 billion dollars, respectively. Even though the strict standard has the largest energy savings, it has a negative economic cost of 1.5 billion dollars to the nation. The cumulative energy savings of the lenient, mid, and strict level standards are 4.2, 10.2, and 20.1 EJ, respectively.

  16. Radiation tests for a single-GEM-loaded gaseous detector

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Kyong Sei; Hong, Byung Sik; Park, Sung Keun [Korea University, Seoul (Korea, Republic of); Kim, Sang Yeol [NoticeKorea, Anyang (Korea, Republic of)

    2014-11-15

    We report on a systematic study of a single-gas-electron-multiplier (GEM)-loaded gaseous detector developed for precision measurements of high-energy particle beams and for dose verification in particle therapy. In the present study, a 256-channel prototype detector having an active area of 16 x 16 cm{sup 2} and operating using a continuous current-integration-mode signal-processing method was manufactured and tested with X-rays emitted from a 70-kV X-ray generator and 43-MeV protons provided by the MC50 proton cyclotron at the Korea Institute of Radiological and Medical Science(KIRAMS). The amplified detector response was measured for X-rays with an intensity of about 5 x 10{sup 6} Hz cm{sup -2}. The linearity of the detector response to the particle flux was examined and validated by using 43-MeV proton beams. The non-uniform development of the amplification for the gas electrons in space was corrected by applying a proper calibration to the channel responses of the measured beam-profile data. We conclude from the radiation tests that the detector developed in the present study will allow us to perform quality measurements of various high-energy particle beams and to apply the technology to dose-verification measurements in particle therapy.

  17. Evaluating operational specifications of point-of-care diagnostic tests: a standardized scorecard.

    Directory of Open Access Journals (Sweden)

    Jonathan D Lehe

    Full Text Available The expansion of HIV antiretroviral therapy into decentralized rural settings will increasingly require simple point-of-care (POC diagnostic tests that can be used without laboratory infrastructure and technical skills. New POC test devices are becoming available but decisions around which technologies to deploy may be biased without systematic assessment of their suitability for decentralized healthcare settings. To address this, we developed a standardized, quantitative scorecard tool to objectively evaluate the operational characteristics of POC diagnostic devices. The tool scores devices on a scale of 1-5 across 30 weighted characteristics such as ease of use, quality control, electrical requirements, shelf life, portability, cost and service, and provides a cumulative score that ranks products against a set of ideal POC characteristics. The scorecard was tested on 19 devices for POC CD4 T-lymphocyte cell counting, clinical chemistry or hematology testing. Single and multi-parameter devices were assessed in each of test categories. The scores across all devices ranged from 2.78 to 4.40 out of 5. The tool effectively ranked devices within each category (p0.80; p<0.001. Use of this tool enables the systematic evaluation of diagnostic tests to facilitate product selection and investment in appropriate technology. It is particularly relevant for countries and testing programs considering the adoption of new POC diagnostic tests.

  18. Private Pilot Practical Test Standards for Lighter-Than-Air Balloon, Airship

    Science.gov (United States)

    1996-06-01

    The Private Pilot - Lighter-Than-Air (Balloon and Airship) Practical Test Standards (PTS) book has been published by the Federal Aviation Administration (FAA) to establish the standards for private pilot certification practical tests for the lighter-...

  19. Flight Instructor Practical Test Standards for Lighter-Than-Air: Balloon, Airship

    Science.gov (United States)

    1995-03-01

    The Flight Instructor - Lighter-Than-Air Practical Test Standards (PTS) : book has been published by the Federal Aviation Administration (FAA) to : establish the standards for flight instructor certification practical tests for : the lighter-than-air...

  20. Commercial Pilot Practical Test Standards for Lighter-Than-Air Balloon, Airship

    Science.gov (United States)

    1997-05-01

    The Commercial Pilot Lighter-Than-Air Practical Test Standards (PTS) book has been published by the Federal Aviation Administration (FAA) to establish the standards for commercial pilot certification practical tests for the lighter-than-air category,...

  1. Standardized testing: a case of annual national assessments in ...

    African Journals Online (AJOL)

    Standardized assessments are becoming a norm internationally. Governments have turned to standardized assessments due to mounting pressure by citizens for accountability, quality education, transparency, and increased public confidence in education. In South Africa, the observed learning deficiencies and prolonged ...

  2. ACCESS, Absolute Color Calibration Experiment for Standard Stars: Integration, Test, and Ground Performance

    Science.gov (United States)

    Kaiser, Mary Elizabeth; Morris, Matthew; Aldoroty, Lauren; Kurucz, Robert; McCandliss, Stephan; Rauscher, Bernard; Kimble, Randy; Kruk, Jeffrey; Wright, Edward L.; Feldman, Paul; Riess, Adam; Gardner, Jonathon; Bohlin, Ralph; Deustua, Susana; Dixon, Van; Sahnow, David J.; Perlmutter, Saul

    2018-01-01

    Establishing improved spectrophotometric standards is important for a broad range of missions and is relevant to many astrophysical problems. Systematic errors associated with astrophysical data used to probe fundamental astrophysical questions, such as SNeIa observations used to constrain dark energy theories, now exceed the statistical errors associated with merged databases of these measurements. ACCESS, “Absolute Color Calibration Experiment for Standard Stars”, is a series of rocket-borne sub-orbital missions and ground-based experiments designed to enable improvements in the precision of the astrophysical flux scale through the transfer of absolute laboratory detector standards from the National Institute of Standards and Technology (NIST) to a network of stellar standards with a calibration accuracy of 1% and a spectral resolving power of 500 across the 0.35‑1.7μm bandpass. To achieve this goal ACCESS (1) observes HST/ Calspec stars (2) above the atmosphere to eliminate telluric spectral contaminants (e.g. OH) (3) using a single optical path and (HgCdTe) detector (4) that is calibrated to NIST laboratory standards and (5) monitored on the ground and in-flight using a on-board calibration monitor. The observations are (6) cross-checked and extended through the generation of stellar atmosphere models for the targets. The ACCESS telescope and spectrograph have been designed, fabricated, and integrated. Subsystems have been tested. Performance results for subsystems, operations testing, and the integrated spectrograph will be presented. NASA sounding rocket grant NNX17AC83G supports this work.

  3. Standard test method for measuring waste glass or glass ceramic durability by vapor hydration test

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 The vapor hydration test method can be used to study the corrosion of a waste forms such as glasses and glass ceramics upon exposure to water vapor at elevated temperatures. In addition, the alteration phases that form can be used as indicators of those phases that may form under repository conditions. These tests; which allow altering of glass at high surface area to solution volume ratio; provide useful information regarding the alteration phases that are formed, the disposition of radioactive and hazardous components, and the alteration kinetics under the specific test conditions. This information may be used in performance assessment (McGrail et al, 2002 (1) for example). 1.2 This test method must be performed in accordance with all quality assurance requirements for acceptance of the data. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practice...

  4. Standard Test Method for Oxyacetylene Ablation Testing of Thermal Insulation Materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 This test method covers the screening of ablative materials to determine the relative thermal insulation effectiveness when tested as a flat panel in an environment of a steady flow of hot gas provided by an oxyacetylene burner. 1.2 This test method should be used to measure and describe the properties of materials, products, or assemblies in response to heat and flame under controlled laboratory conditions and should not be used to describe or appraise the fire hazard of materials, products, or assemblies under actual fire conditions. However, results of this test method may be used as elements of a fire risk assessment which takes into account all of the factors which are pertinent to an assessment of the fire hazard of a particular end use. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limi...

  5. Using standard serology blood tests to diagnose latent syphilis

    Directory of Open Access Journals (Sweden)

    G. L. Katunin

    2016-01-01

    Full Text Available Goal. To conduct a comparative assessment of the results of regulated serological tests obtained as a result of blood tests in patients suffering from latent syphilis. Materials and methods. The authors examined 187 patient medical records with newly diagnosed latent syphilis in FGBU GNTsDK (State Research Center for Dermatology, Venereology and Cosmetology, Health Ministry of the Russian Federation, in 2006-2015. The results of patient blood tests were analyzed with the use of non-treponemal (microprecipitation test/RPR and treponemal (passive hemagglutination test, immune-enzyme assay (IgA, IgM, IgG, IFabs, immunofluorescence test and Treponema pallidum immobilization test serology tests. Results. According to the results of blood tests of latent syphilis patients, the largest number of positive results was obtained as a result of treponemal serology tests such as immune-enzyme assay (100%, passive hemagglutination test (100% and IFabs (100%. The greatest number of negative results was observed in non-treponemal (microprecipitation test/RPR serology tests: in 136 (72.7% patients; evidently positive results (4+ test results were obtained in 8 (4.3% patients only. According to the results of a comparative analysis of blood tests in patients suffering from latent syphilis obtained with the use of treponemal serology tests, the greatest number of evidently positive results (4+ was noted for the passive hemagglutination test (67.9%. Negative treponemal test results were obtained with the use of the immunofluorescence test and Treponema pallidum immobilization test (21.9% and 11.8% of cases, respectively. Moreover, weakly positive results prevailed for the immunofluorescence test: in 65 (34.7% patients. Conclusion. These data confirm that the following treponemal tests belong to the most reliable ones for revealing patients suffering from latent syphilis: immune-enzyme assay, passive hemagglutination test and IFabs.

  6. 29 CFR 1630.10 - Qualification standards, tests, and other selection criteria.

    Science.gov (United States)

    2010-07-01

    ... DISABILITIES ACT § 1630.10 Qualification standards, tests, and other selection criteria. It is unlawful for a covered entity to use qualification standards, employment tests or other selection criteria that screen..., on the basis of disability, unless the standard, test or other selection criteria, as used by the...

  7. Analysis of experiment testing technology for single event effects in China

    International Nuclear Information System (INIS)

    He Chaohui

    2001-01-01

    The merit and demerit of simulation source were analyzed for Single Event Effects (SEE) experiment testing in China. Laboratory experiment systems for SEE were brief introduced and requests for SEE test system were emphasize analyzed. Test systems were presented for Single Event Upset, Single Event Latch-up, Single Event Burnout and Single Event Gate-Rupture. The attention should be in mind in SEE experiments were discussed

  8. SMC Standard: Evaluation and Test Requirements for Liquid Rocket Engines

    Science.gov (United States)

    2017-07-26

    78 8.2 Pre-Launch Validation and Operational Tests ...................................................................... 78 8.2.1 General...completion of the development test program. The phase includes validation of test techniques, procedures, equipment, instrumentation, and software, as... reliability for flight operations. A corollary to TLYF is the “fly-as-you- test ” approach. “Fly-as-you- test ” means that flight operation should remain

  9. Annual meeting 1996 'Nondestructive materials testing'. German, Austrian and Swiss nondestructive materials testing standards as mirrored by international standardization. Vol. 1. Lectures

    International Nuclear Information System (INIS)

    1996-01-01

    The volume contains 45 lectures which were given at the annual meeting of the German Society for Nondestructive Testing on May 13-15, 1996 at Lindau. The main subjects were: Standardization of nondestructive testing, irradiation testing, ultrasonic testing and electromagnetic processes. 13 individual articles were included in the ENERGY database. (MM) [de

  10. Annual meeting 1996 'Nondestructive material testing'. German, Austrian and Swiss nondestructive materials testing standards as mirrored by international standardization. Vol. 2. Posters

    International Nuclear Information System (INIS)

    1996-01-01

    The volume contains 49 poster articles which were presented at the Annual Meeting of the German Society for Nondestructive Testing at Lindau on May 13-15, 1996. The main subjects were: Standardization of nondestructive testing, irradiation testing, ultrasonic testing and electromagnetic processes. 16 individual articles were included in the ENERGY databank. (MM) [de

  11. Tests of the standard electroweak model in beta decay

    Energy Technology Data Exchange (ETDEWEB)

    Severijns, N.; Beck, M. [Universite Catholique de Louvain (UCL), Louvain-la-Neuve (Belgium); Naviliat-Cuncic, O. [Caen Univ., CNRS-ENSI, 14 (France). Lab. de Physique Corpusculaire

    2006-05-15

    We review the current status of precision measurements in allowed nuclear beta decay, including neutron decay, with emphasis on their potential to look for new physics beyond the standard electroweak model. The experimental results are interpreted in the framework of phenomenological model-independent descriptions of nuclear beta decay as well as in some specific extensions of the standard model. The values of the standard couplings and the constraints on the exotic couplings of the general beta decay Hamiltonian are updated. For the ratio between the axial and the vector couplings we obtain C{sub A},/C{sub V} = -1.26992(69) under the standard model assumptions. Particular attention is devoted to the discussion of the sensitivity and complementarity of different precision experiments in direct beta decay. The prospects and the impact of recent developments of precision tools and of high intensity low energy beams are also addressed. (author)

  12. Standard test method for radiochemical determination of uranium isotopes in soil by alpha spectrometry

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2011-01-01

    1.1 This test method covers the determination of alpha-emitting uranium isotopes in soil. This test method describes one acceptable approach to the determination of uranium isotopes in soil. 1.2 The test method is designed to analyze 10 g of soil; however, the sample size may be varied to 50 g depending on the activity level. This test method may not be able to completely dissolve all forms of uranium in the soil matrix. Studies have indicated that the use of hydrofluoric acid to dissolve soil has resulted in lower values than results using total dissolution by fusion. 1.3 The lower limit of detection is dependent on count time, sample size, detector, background, and tracer yield. The chemical yield averaged 78 % in a single laboratory evaluation, and 66 % in an interlaboratory collaborative study. 1.4 The values stated in SI units are to be regarded as standard. The values given in parentheses are for information only. 1.5 This standard does not purport to address all of the safety concerns, if any, ass...

  13. Columbia University flow instability experimental program: Volume 6. Single annulus tests, transient test program

    Energy Technology Data Exchange (ETDEWEB)

    Dougherty, T.; Maciuca, C.; McAssey, E.V. Jr.; Reddy, D.G.; Yang, B.W.

    1992-09-01

    The coolant in the Savannah River Site (SRS) production nuclear reactor assemblies is circulated as a subcooled liquid under normal operating conditions. This coolant is evenly distributed throughout multiple annular flow channels with a uniform pressure profile across each coolant flow channel. During the postulated Loss of Coolant Accident (LOCA), which is initiated by a hypothetical guillotine pipe break, the coolant flow through the reactor assemblies is significantly reduced. The flow reduction and accompanying power reduction (after shutdown is initiated) occur in the first 1 to 2 seconds of the LOCA. This portion of the LOCA is referred to as the Flow Instability phase. This report presents the experimental results for the transient portion of the single annulus test program. The test program was designed to investigate the onset of flow instability in an annular geometry similar to the MARK 22 reactor. The test program involved testing of both a ribless heater and a ribbed heater under steady state as well as transient conditions. The ribbed heater testing is currently underway and will be reported separately. The steady state portion of this test program with ribless heater was completed and reported in report No. CU-HTRF-T3A. The present report presents transient test results obtained from a ribless, uniform annulus test section. A total of thirty five transients were conducted with six cases in which flow excursion occurred. No unstable conditions resulted for tests in which the steady state Q{sub ratio} OFI limit was not exceeded.

  14. Laparoendoscopic single-site (LESS retroperitoneal partial adrenalectomy using a custom-made single-access platform and standard laparoscopic instruments: Technical considerations and surgical outcomes

    Directory of Open Access Journals (Sweden)

    Chen-Hsun Ho

    2015-01-01

    Conclusion: Our results clearly demonstrate that LESS retroperitoneal partial adrenalectomy can be performed safely and effectively using a custom-made single-access platform and standard laparoscopic instruments.

  15. Practical issues for testing thin film PV modules at standard test conditions.

    OpenAIRE

    Marín González, Omar; Raga Arroyo, Manuela Pilar; Alonso Garcia, M. Carmen; Muñoz-García, Miguel Angel

    2013-01-01

    Thin film photovoltaic (TF) modules have gained importance in the photovoltaic (PV) market. New PV plants increasingly use TF technologies. In order to have a reliable sample of a PV module population, a huge number of modules must be measured. There is a big variety of materials used in TF technology. Some of these modules are made of amorphous or microcrystalline silicon. Other are made of CIS or CdTe. Not all these materials respond the same under standard test conditions (STC) of power...

  16. Undergraduate Students' Errors in the Administration of Standardized Tests.

    Science.gov (United States)

    Giacobbe, George A.; Traynelis-Yurek, Elaine

    1989-01-01

    Undergraduate students (N=106) in a psychoeducational testing course were required to administer the Peabody Picture Vocabulary Test-Revised to the instructor. Only 29.2 percent were able to administer the test error-free, indicating that a one-semester course is insufficient preparation for special educators to become effective test…

  17. 49 CFR 232.307 - Modification of the single car air brake test procedures.

    Science.gov (United States)

    2010-10-01

    ... Requirements § 232.307 Modification of the single car air brake test procedures. (a) Request. The AAR or other authorized representative of the railroad industry may seek modification of the single car air brake test... 49 Transportation 4 2010-10-01 2010-10-01 false Modification of the single car air brake test...

  18. Primordial alchemy: a test of the standard model

    International Nuclear Information System (INIS)

    Steigman, G.

    1987-01-01

    Big Bang Nucleosynthesis provides the only probe of the early evolution of the Universe constrained by observational data. The standard, hot, big bang model predicts the synthesis of the light elements (D, 3 He, 4 He, 7 Li) in astrophysically interesting abundances during the first few minutes in the evolution of the Universe. A quantitative comparison of the predicted abundances with those observed astronomically confirms the consistency of the standard model and yields valuable constraints on the parameters of cosmology and elementary particle physics. The current status of the comparison between theory and observation will be reviewed and the opportunities for future advances outlined

  19. 49 CFR 219.701 - Standards for drug and alcohol testing.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Standards for drug and alcohol testing. 219.701... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION CONTROL OF ALCOHOL AND DRUG USE Drug and Alcohol Testing Procedures § 219.701 Standards for drug and alcohol testing. (a) Drug testing required or authorized by subparts B...

  20. Standard Test Method for Hot Spot Protection Testing of Photovoltaic Modules

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 This test method provides a procedure to determine the ability of a photovoltaic (PV) module to endure the long-term effects of periodic “hot spot” heating associated with common fault conditions such as severely cracked or mismatched cells, single-point open circuit failures (for example, interconnect failures), partial (or non-uniform) shadowing or soiling. Such effects typically include solder melting or deterioration of the encapsulation, but in severe cases could progress to combustion of the PV module and surrounding materials. 1.2 There are two ways that cells can cause a hot spot problem; either by having a high resistance so that there is a large resistance in the circuit, or by having a low resistance area (shunt) such that there is a high-current flow in a localized region. This test method selects cells of both types to be stressed. 1.3 This test method does not establish pass or fail levels. The determination of acceptable or unacceptable results is beyond the scope of this test method....

  1. Laboratory test descriptions for bovine respiratory disease diagnosis and their strengths and weaknesses: gold standards for diagnosis, do they exist?

    Science.gov (United States)

    Fulton, Robert W; Confer, Anthony W

    2012-07-01

    The diagnosis of bovine respiratory diseases (BRD) poses significant challenges to the clinician as there are numerous infectious etiologies, operating singly or most often in combination. Clinical signs alone may not be diagnostic and the diagnostic laboratory is often used to assist the clinician. Recently many molecular-based tests have been taken from the research laboratory to the veterinary diagnostic laboratory. This review describes the "traditional tests" and several "molecular tests" and discusses the benefits and limitations of the tests and their interpretation. Clinicians should consult with their diagnostic laboratory regarding the interpretation of the test results. The rate of development and use of molecular diagnostic tests have outpaced validation, standardization, and standards for interpretation relative to their use in BRD diagnostics.

  2. New ASTM Standards for Nondestructive Testing of Aerospace Composites

    Science.gov (United States)

    Waller, Jess M.; Saulsberry, Regor L.

    2010-01-01

    Problem: Lack of consensus standards containing procedural detail for NDE of polymer matrix composite materials: I. Flat panel composites. II. Composite components with more complex geometries a) Pressure vessels: 1) composite overwrapped pressure vessels (COPVs). 2) composite pressure vessels (CPVs). III. Sandwich core constructions. Metal and brittle matrix composites are a possible subject of future effort.

  3. Precision tests of the standard model at LEP

    International Nuclear Information System (INIS)

    Mele, Barbara; Universita La Sapienza, Rome

    1994-01-01

    Recent LEP results on electroweak precision measurements are reviewed. Line-shape and asymmetries analysis on the Z 0 peak is described. Then, the consistency of the Standard Model predictions with experimental data and consequent limits on the top mass are discussed. Finally, the possibility of extracting information and constrains on new theoretical models from present data is examined. (author). 20 refs., 5 tabs

  4. 42 CFR 493.1489 - Standard; Testing personnel qualifications.

    Science.gov (United States)

    2010-10-01

    ... HUMAN SERVICES (CONTINUED) STANDARDS AND CERTIFICATION LABORATORY REQUIREMENTS Personnel for Nonwaived... biology; and (iii) Twelve semester hours of chemistry, biology, or medical laboratory technology in any... analysis— (i) Be qualified under § 493.1489(b)(1), (b)(2), (b)(3), (b)(4), or (b)(5); (ii) Have earned a...

  5. Standard test methods for arsenic in uranium hexafluoride

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2005-01-01

    1.1 These test methods are applicable to the determination of total arsenic in uranium hexafluoride (UF6) by atomic absorption spectrometry. Two test methods are given: Test Method A—Arsine Generation-Atomic Absorption (Sections 5-10), and Test Method B—Graphite Furnace Atomic Absorption (Appendix X1). 1.2 The test methods are equivalent. The limit of detection for each test method is 0.1 μg As/g U when using a sample containing 0.5 to 1.0 g U. Test Method B does not have the complete collection details for precision and bias data thus the method appears as an appendix. 1.3 Test Method A covers the measurement of arsenic in uranyl fluoride (UO2F2) solutions by converting arsenic to arsine and measuring the arsine vapor by flame atomic absorption spectrometry. 1.4 Test Method B utilizes a solvent extraction to remove the uranium from the UO2F2 solution prior to measurement of the arsenic by graphite furnace atomic absorption spectrometry. 1.5 Both insoluble and soluble arsenic are measured when UF6 is...

  6. Reliability testing of indirect composites as single implant restorations.

    Science.gov (United States)

    Suzuki, Marcelo; Bonfante, Estevam; Silva, Nelson Rfa; Coelho, Paulo G

    2011-10-01

    To investigate the reliability and failure modes of indirect composites as single-unit implant crowns. Thirty-eight custom-milled titanium alloy locking-taper abutments were divided into two groups (n = 19 each), and crown build-up of a mandibular molar was accomplished using two indirect composite systems (Ceramage, Shofu, Kyoto, Japan; Diamond Crown, DRM, Branford, CT). Three crowns of each material were loaded until failure for determination of the step-stress profiles. Reliability testing started at a load 30% of the mean load to failure and used three profiles with increasing fatigue loading (step stress). Weibull curves with 300 N stress and 90% confidence intervals were calculated and plotted using a power-law relationship. Weibull modulus "Beta" and characteristic strength "Eta" were identified, and a contour plot was used (Beta vs. Eta) for examining differences between groups. Specimens were inspected in polarized light and scanning electron microscope for fracture analysis. Use level Weibull probability showed fatigue being a damage factor only for the Ceramage group (β= 3.39) but not for the Diamond Crown group (β= 0.40). Overlap in the confidence bounds resulted in no statistical difference. Irrespective of composite system, fracture initiated in the region immediately below the contact between the indenter and the cusp, with the crack propagating toward the margins of cohesive failure. No significant differences were observed in life and Weibull probability calculations for Ceramage and Diamond Crown veneered onto Ti alloy abutments. Failure modes comprised composite veneer chippings. © 2011 by The American College of Prosthodontists.

  7. Standard test method for electrochemical critical pitting temperature testing of stainless steels

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1999-01-01

    1.1 This test method covers a procedure for the evaluation of the resistance of stainless steel and related alloys to pitting corrosion based on the concept of the determination of a potential independent critical pitting temperature (CPT). 1.2 This test methods applies to wrought and cast products including but not restricted to plate, sheet, tubing, bar, forgings, and welds, (see Note 1). Note 1—Examples of CPT measurements on sheet, plate, tubing, and welded specimens for various stainless steels can be found in Ref (1). See the research reports (Section 14). 1.3 The standard parameters recommended in this test method are suitable for characterizing the CPT of austenitic stainless steels and other related alloys with a corrosion resistance ranging from that corresponding to solution annealed UNS S31600 (Type 316 stainless steel) to solution annealed UNS S31254 (6 % Mo stainless steel). 1.4 This test method may be extended to stainless steels and other alloys related to stainless steel that have a CPT...

  8. Airside HVAC BESTEST: HVAC Air-Distribution System Model Test Cases for ASHRAE Standard 140

    Energy Technology Data Exchange (ETDEWEB)

    Judkoff, Ronald [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Neymark, Joel [J. Neymark & Associates; Kennedy, Mike D. [Mike D. Kennedy, Inc.; Gall, J. [AAON, Inc.; Henninger, R. [GARD Analytics, Inc.; Hong, T. [Lawrence Berkeley National Laboratory; Knebel, D. [AAON, Inc.; McDowell, T. [Thermal Energy System Specialists, LLC; Witte, M. [GARD Analytics, Inc.; Yan, D. [Tsinghua University; Zhou, X. [Tsinghua University

    2017-08-07

    This paper summarizes recent work to develop new airside HVAC equipment model analytical verification test cases for ANSI/ASHRAE Standard 140, Standard Method of Test for the Evaluation of Building Energy Analysis Computer Programs. The analytical verification test method allows comparison of simulation results from a wide variety of building energy simulation programs with quasi-analytical solutions, further described below. Standard 140 is widely cited for evaluating software for use with performance-path energy efficiency analysis, in conjunction with well-known energy-efficiency standards including ASHRAE Standard 90.1, the International Energy Conservation Code, and other international standards. Airside HVAC Equipment is a common area of modelling not previously explicitly tested by Standard 140. Integration of the completed test suite into Standard 140 is in progress.

  9. 42 CFR 493.1425 - Standard; Testing personnel responsibilities.

    Science.gov (United States)

    2010-10-01

    ... authorized by the laboratory director and require a degree of skill commensurate with the individual's... test results and either must correct the problems or immediately notify the technical consultant, clinical consultant or director; and (6) Document all corrective actions taken when test systems deviate...

  10. Standardization of incubation conditions for hemolysis testing of biomaterials

    NARCIS (Netherlands)

    Henkelman, Sandra; Rakhorst, Gerhard; Blanton, John; van Oeveren, Willem

    2009-01-01

    Hemolysis testing is the most common method to determine the hemocompatibility properties of biomaterials. There is however no consensus on the procedures of hemolysis testing due to insufficient comparative studies on the quality of the red blood cells used and the experimental conditions of

  11. 40 CFR 51.357 - Test procedures and standards.

    Science.gov (United States)

    2010-07-01

    ... following steps: (i) Test equipment shall be connected to the fuel tank canister hose at the canister end... minutes and monitor for a sudden pressure drop, indicating that the fuel tank was pressurized. (v) The... be performed without repair or adjustment at the inspection facility, prior to the test, except as...

  12. Single-Case Experimental Designs: A Systematic Review of Published Research and Current Standards

    Science.gov (United States)

    Smith, Justin D.

    2013-01-01

    This article systematically reviews the research design and methodological characteristics of single-case experimental design (SCED) research published in peer-reviewed journals between 2000 and 2010. SCEDs provide researchers with a flexible and viable alternative to group designs with large sample sizes. However, methodological challenges have precluded widespread implementation and acceptance of the SCED as a viable complementary methodology to the predominant group design. This article includes a description of the research design, measurement, and analysis domains distinctive to the SCED; a discussion of the results within the framework of contemporary standards and guidelines in the field; and a presentation of updated benchmarks for key characteristics (e.g., baseline sampling, method of analysis), and overall, it provides researchers and reviewers with a resource for conducting and evaluating SCED research. The results of the systematic review of 409 studies suggest that recently published SCED research is largely in accordance with contemporary criteria for experimental quality. Analytic method emerged as an area of discord. Comparison of the findings of this review with historical estimates of the use of statistical analysis indicates an upward trend, but visual analysis remains the most common analytic method and also garners the most support amongst those entities providing SCED standards. Although consensus exists along key dimensions of single-case research design and researchers appear to be practicing within these parameters, there remains a need for further evaluation of assessment and sampling techniques and data analytic methods. PMID:22845874

  13. Developing and Standardization of a Diagnostic Reading Test

    Directory of Open Access Journals (Sweden)

    Tahereh Sima-Shirazi

    2004-06-01

    Full Text Available Objective: This paper is a report on the development, structure and content of a diagnostic dyslexia reading test. The target population of this test is persian children who have problems in learning reading and may be considered as dyslexic. This diagnostic test is the first reading test developed for the native speakers of persian. Materials & Methods: The theoretical framework of the test is based on two well- established reading tests for the English speaking children, namely Durrell Analysis of Reading and Neale Analysis of Reading Ability. The linguistic content of the subtests is selected from the vocabulary and texts of the textbook used in the primary schools. Both the vocabulary and the sentences of the parrallel passeges were controlled for frequency, phonemic/graphemic regularity, syllable structure, morphology, syntax and semantics. They were also controlled for value judgement by two linguistics and three first grader teachers.The first version of the test is normed on 605 boy and girl first graders from different educational sectors and schools selected randomly.The method used in this research is cross- sectional, descriptive- analytic and the data analysis is based on pearson, and mann-whitney u. Results: Reliability of the test is calculated based on parrallel forms (~ 90% and validity is based on content validity.This test has a supplementary section including spelling, graphem/ phoneme correspondness, nonword reading, irregular word reading, and copy subtests. Conclusion: Considering highreliability and precise validation of the test it can be used to diagnose the dyslexia and related linguistic impairments.

  14. Exploring and testing the Standard Model and beyond

    International Nuclear Information System (INIS)

    West, G.; Cooper, F.; Ginsparg, P.; Habib, S.; Gupta, R.; Mottola, E.; Nieto, M.; Mattis, M.

    1998-01-01

    This is the final report of a three-year, Laboratory Directed Research and Development (LDRD) project at Los Alamos National Laboratory (LANL). The goal of this project was to extend and develop the predictions of the Standard Model of particle physics in several different directions. This includes various aspects of the strong nuclear interactions in quantum chromodynamics (QCD), electroweak interactions and the origin of baryon asymmetry in the universe, as well as gravitational physics

  15. Test Standards for Contingency Base Waste-to-Energy Technologies

    Science.gov (United States)

    2015-08-01

    standard and challenge recipes by weight percent ........6 Table 3 Recommended breakout of plastic recipes by weight percent ...............7 Table 4...to select the appropriate VOC and SVOC target compounds, it is recommended to review the list of hazardous air pollutants provided in 42 United...Class A explosives, or Class B explosives classifications. Toxicity: Toxic wastes are harmful or fatal when ingested or absorbed. When toxic wastes

  16. Column percolation test for contaminated soils: Key factors for standardization.

    Science.gov (United States)

    Naka, Angelica; Yasutaka, Tetsuo; Sakanakura, Hirofumi; Kalbe, Ute; Watanabe, Yasutaka; Inoba, Seiji; Takeo, Miyuki; Inui, Toru; Katsumi, Takeshi; Fujikawa, Takuro; Sato, Kenichi; Higashino, Kazuo; Someya, Masayuki

    2016-12-15

    Column percolation tests may be suitable for prediction of chemical leaching from soil and soil materials. However, compared with batch leaching tests, they are time-consuming. It is therefore important to investigate ways to shorten the tests without affecting the quality of results. In this study, we evaluate the feasibility of decreasing testing time by increasing flow rate and decreasing equilibration time compared to the conditions specified in ISO/TS 21268-3, with equilibration periods of 48h and flow rate of 12mL/h. We tested three equilibration periods (0, 12-16, and 48h) and two flow rates (12 and 36mL/h) on four different soils and compared the inorganic constituent releases. For soils A and D, we observed similar values for all conditions except for the 0h-36mL/h case. For soil B, we observed no appreciable differences between the tested conditions, while for soil C there were no consistent trends probably due to the difference in ongoing oxidation reactions between soil samples. These results suggest that column percolation tests can be shortened from 20 to 30days to 7-9days by decreasing the equilibration time to 12-16h and increasing the flow rate to 36mL/h for inorganic substances. Copyright © 2016 The Author(s). Published by Elsevier B.V. All rights reserved.

  17. Standard Test Methods for Determining Mechanical Integrity of Photovoltaic Modules

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 These test methods cover procedures for determining the ability of photovoltaic modules to withstand the mechanical loads, stresses and deflections used to simulate, on an accelerated basis, high wind conditions, heavy snow and ice accumulation, and non-planar installation effects. 1.1.1 A static load test to 2400 Pa is used to simulate wind loads on both module surfaces 1.1.2 A static load test to 5400 Pa is used to simulate heavy snow and ice accumulation on the module front surface. 1.1.3 A twist test is used to simulate the non-planar mounting of a photovoltaic module by subjecting it to a twist angle of 1.2°. 1.1.4 A cyclic load test of 10 000 cycles duration and peak loading to 1440 Pa is used to simulate dynamic wind or other flexural loading. Such loading might occur during shipment or after installation at a particular location. 1.2 These test methods define photovoltaic test specimens and mounting methods, and specify parameters that must be recorded and reported. 1.3 Any individual mech...

  18. Standard Test Method for Contamination Outgassing Characteristics of Spacecraft Materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This test method covers a technique for generating data to characterize the kinetics of the release of outgassing products from materials. This technique will determine both the total mass flux evolved by a material when exposed to a vacuum environment and the deposition of this flux on surfaces held at various specified temperatures. 1.2 This test method describes the test apparatus and related operating procedures for evaluating the total mass flux that is evolved from a material being subjected to temperatures that are between 298 and 398 K. Pressures external to the sample effusion cell are less than 7 × 10−3 Pa (5 × 10−5 torr). Deposition rates are measured during material outgassing tests. A test procedure for collecting data and a test method for processing and presenting the collected data are included. 1.3 This test method can be used to produce the data necessary to support mathematical models used for the prediction of molecular contaminant generation, migration, and deposition. 1.4 Al...

  19. Standard test method for measurement of fatigue crack growth rates

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2015-01-01

    1.1 This test method covers the determination of fatigue crack growth rates from near-threshold to Kmax controlled instability. Results are expressed in terms of the crack-tip stress-intensity factor range (ΔK), defined by the theory of linear elasticity. 1.2 Several different test procedures are provided, the optimum test procedure being primarily dependent on the magnitude of the fatigue crack growth rate to be measured. 1.3 Materials that can be tested by this test method are not limited by thickness or by strength so long as specimens are of sufficient thickness to preclude buckling and of sufficient planar size to remain predominantly elastic during testing. 1.4 A range of specimen sizes with proportional planar dimensions is provided, but size is variable to be adjusted for yield strength and applied force. Specimen thickness may be varied independent of planar size. 1.5 The details of the various specimens and test configurations are shown in Annex A1-Annex A3. Specimen configurations other than t...

  20. 40 CFR 82.38 - Approved independent standards testing organizations.

    Science.gov (United States)

    2010-07-01

    ... equipment testing and the technical experience of the organization's personnel; (iii) Thorough knowledge of... procedures are appropriate for that purpose. (2) That the organization has no conflict of interest and will...

  1. Environmental test planning, selection and standardization aids available

    Science.gov (United States)

    Copeland, E. H.; Foley, J. T.

    1968-01-01

    Requirements for instrumentation, equipment, and methods to be used in conducting environmental tests on components intended for use by a wide variety of technical personnel of different educational backgrounds, experience, and interests is announced.

  2. Development and standardization of perafom integrated aptitude test

    African Journals Online (AJOL)

    / selection/ placement and the measurement of intelligence prompted the development of Perafom Integrated Aptitude Test (PIAT). Following the due psychometric process of item selection, PIAT comprises 40 items derived from several ...

  3. Standard Operating Procedure for Accelerated Corrosion Testing at ARL

    Science.gov (United States)

    2017-11-01

    to scribe nonferrous materials so as to prevent contamination of the substrate during the process. The "X" scribe is made by scribing 2 intersecting...may include GMW14872 Cyclic Corrosion Testing (typically Exterior, Exposure C), ASTM B117 Neutral Salt Fog Testing, ASTM G50 Atmospheric Corrosion...using the same cleaning procedures, contamination of the substrate is minimized during the scribe process. All partners adhering to guidelines and

  4. Predicting standard penetration test N-value from cone penetration test data using artificial neural networks

    Directory of Open Access Journals (Sweden)

    Bashar Tarawneh

    2017-01-01

    Full Text Available Standard Penetration Test (SPT and Cone Penetration Test (CPT are the most frequently used field tests to estimate soil parameters for geotechnical analysis and design. Numerous soil parameters are related to the SPT N-value. In contrast, CPT is becoming more popular for site investigation and geotechnical design. Correlation of CPT data with SPT N-value is very beneficial since most of the field parameters are related to SPT N-values. A back-propagation artificial neural network (ANN model was developed to predict the N60-value from CPT data. Data used in this study consisted of 109 CPT-SPT pairs for sand, sandy silt, and silty sand soils. The ANN model input variables are: CPT tip resistance (qc, effective vertical stress (σv′, and CPT sleeve friction (fs. A different set of SPT-CPT data was used to check the reliability of the developed ANN model. It was shown that ANN model either under-predicted the N60-value by 7–16% or over-predicted it by 7–20%. It is concluded that back-propagation neural networks is a good tool to predict N60-value from CPT data with acceptable accuracy.

  5. A standard screening test for the early and rapid diagnosis of leptospirosis

    Directory of Open Access Journals (Sweden)

    Chandrasekaran S

    2004-01-01

    Full Text Available PURPOSE : To perform dark field microscopy (DFM for detection of Leptospira and to validate the results using Leptospira IgM antibody SERION ELISA test. METHODS : After differential centrifugation of Ruys, DFM was done to demonstrate Leptospira in the blood and SERION ELISA was done for Leptospira IgM antibody in single or paired serum samples. One hundred and eleven cases (39 adults and 72 children of suspected leptospirosis were included in the study. RESULTS : Anicteric cases accounted for 66.7% (26/39 of adults and complications involving brain, liver, kidney and eyes were seen in 33.3% (13/39. In children, 90.3% (65/72 were anicteric and involvement of brain and liver was seen in 9.7% (7/72 cases. On testing 60 single samples of blood from 23 adults and 37 children, DFM exhibited greater sensitivity of 93.3% (56/60 than that of SERION ELISA for Leptospira IgM antibody (33.3%, 20/60. It was observed that the positivity of DFM decreased from 100% (15/15 to 90.9% (10/11 with increase in the duration of infection for more than one week. ELISA for Leptospira IgM, done on 51 paired blood samples, was positive in 64.7% (33/51 cases when both (first and second samples were tested while in 45.1% (23/51 cases was positive with first sample alone. 58.8%(30/51 cases were positive by testing second sample. DFM results on paired blood samples showed persistence of Leptospira in 92.9% of cases. CONCLUSION : This study shows the validation of DFM results by SERION ELISA for Leptospira IgM antibody, based on which we recommend that DFM can serve as a standard screening test for early and rapid diagnosis of leptospirosis.

  6. Fractional flow reserve derived from coronary CT angiography in stable coronary disease: a new standard in non-invasive testing?

    Energy Technology Data Exchange (ETDEWEB)

    Noergaard, B.L.; Jensen, J.M. [Aarhus University Hospital Skejby, Department of Cardiology B, Aarhus N (Denmark); Leipsic, J. [St. Paul' s Hospital, Department Radiology, Vancouver, British Columbia (Canada)

    2015-08-15

    Fractional flow reserve (FFR) measured during invasive coronary angiography is the gold standard for lesion-specific decisions on coronary revascularization in patients with stable coronary artery disease (CAD). Current guidelines recommend non-invasive functional or anatomic testing as a gatekeeper to the catheterization laboratory. However, the ''holy grail'' in non-invasive testing of CAD is to establish a single test that quantifies both coronary lesion severity and the associated ischemia. Most evidence to date of such a test is based on the addition of computational analysis of FFR to the anatomic information obtained from standard-acquired coronary CTA data sets at rest (FFR{sub CT}). This review summarizes the clinical evidence for the use of FFR{sub CT} in stable CAD in context to the diagnostic performance of other non-invasive testing modalities. (orig.)

  7. Fractional flow reserve derived from coronary CT angiography in stable coronary disease: a new standard in non-invasive testing?

    International Nuclear Information System (INIS)

    Noergaard, B.L.; Jensen, J.M.; Leipsic, J.

    2015-01-01

    Fractional flow reserve (FFR) measured during invasive coronary angiography is the gold standard for lesion-specific decisions on coronary revascularization in patients with stable coronary artery disease (CAD). Current guidelines recommend non-invasive functional or anatomic testing as a gatekeeper to the catheterization laboratory. However, the ''holy grail'' in non-invasive testing of CAD is to establish a single test that quantifies both coronary lesion severity and the associated ischemia. Most evidence to date of such a test is based on the addition of computational analysis of FFR to the anatomic information obtained from standard-acquired coronary CTA data sets at rest (FFR CT ). This review summarizes the clinical evidence for the use of FFR CT in stable CAD in context to the diagnostic performance of other non-invasive testing modalities. (orig.)

  8. Quality standards for sample collection in coagulation testing.

    Science.gov (United States)

    Lippi, Giuseppe; Salvagno, Gian Luca; Montagnana, Martina; Lima-Oliveira, Gabriel; Guidi, Gian Cesare; Favaloro, Emmanuel J

    2012-09-01

    Preanalytical activities, especially those directly connected with blood sample collection and handling, are the most vulnerable steps throughout the testing process. The receipt of unsuitable samples is commonplace in laboratory practice and represents a serious problem, given the reliability of test results can be adversely compromised following analysis of these specimens. The basic criteria for an appropriate and safe venipuncture are nearly identical to those used for collecting blood for clinical chemistry and immunochemistry testing, and entail proper patient identification, use of the correct technique, as well as appropriate devices and needles. There are, however, some peculiar aspects, which are deemed to be particularly critical when collecting quality specimens for clot-based tests, and these require clearer recognition. These include prevention of prolonged venous stasis, collection of nonhemolyzed specimens, order of draw, and appropriate filling and mixing of the primary collection tubes. All of these important preanalytical issues are discussed in this article, and evidence-based suggestions as well as recommendations on how to obtain a high-quality sample for coagulation testing are also illustrated. We have also performed an investigation aimed to identify variation of test results due to underfilling of primary blood tubes, and have identified a clinically significant bias in test results when tubes are drawn at less than 89% of total fill for activated partial thromboplastin time, less than 78% for fibrinogen, and less than 67% for coagulation factor VIII, whereas prothrombin time and activated protein C resistance remain relatively reliable even in tubes drawn at 67% of the nominal volume. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  9. Standard practice for ultrasonic testing of wrought products

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2013-01-01

    1.1 Purpose—This practice establishes the minimum requirements for ultrasonic examination of wrought products. Note 1—This standard was adopted to replace MIL-STD-2154, 30 Sept. 1982. This standard is intended to be used for the same applications as the document which it replaced. Users should carefully review its requirements when considering its use for new, or different applications, or both. 1.2 Application—This practice is applicable for examination of materials such as, wrought metals and wrought metal products. 1.2.1 Wrought Aluminum Alloy Products—Examination shall be in accordance with Practice B 594. 1.3 Acceptance Class—When examination is performed in accordance with this practice, engineering drawings, specifications, or other applicable documents shall indicate the acceptance criteria. Five ultrasonic acceptance classes are defined in Table 1. One or more of these classes may be used to establish the acceptance criteria or additional or alternate criteria may be specified. 1.4 Ord...

  10. Evaluation of Desensol As a Standard Patch Test Kit

    Directory of Open Access Journals (Sweden)

    K C Shah

    1987-01-01

    Full Text Available In a study undertaken to find out the usefulness of ′Desensol′ patch test kit to detect contact allergens, in 200 cases revealed 24 cases with negative patch test with all the antigens and 55 cases reacted to even the Vaseline control. -Excluding these 79 cases, the common contact allergens were potassium bichr6ma,te, (40.49%, TMTD(28.92%, PPD(24.79%, epoxy resin (23.14%, colophony (19.0%, nickel sulfate (19.0%, Framycetin (19.0% and nitrofurazone (19.0%. Desensol patch test kit is lacking in certain antigens while in our country due to varied environmental factors and social customs, a person is exposed to a large number of natural and man-made contact allergens. So usefulness of such a kit like. Desensol is limited.

  11. Analysis of Individual "Test Of Astronomy STandards" (TOAST) Item Responses

    Science.gov (United States)

    Slater, Stephanie J.; Schleigh, Sharon Price; Stork, Debra J.

    2015-01-01

    The development of valid and reliable strategies to efficiently determine the knowledge landscape of introductory astronomy college students is an effort of great interest to the astronomy education community. This study examines individual item response rates from a widely used conceptual understanding survey, the Test Of Astronomy Standards…

  12. Standard Test Methods for Constituent Content of Composite Materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 These test methods determine the constituent content of composite materials by one of two approaches. Method I physically removes the matrix by digestion or ignition by one of seven procedures, leaving the reinforcement essentially unaffected and thus allowing calculation of reinforcement or matrix content (by weight or volume) as well as percent void volume. Method II, applicable only to laminate materials of known fiber areal weight, calculates reinforcement or matrix content (by weight or volume), and the cured ply thickness, based on the measured thickness of the laminate. Method II is not applicable to the measurement of void volume. 1.1.1 These test methods are primarily intended for two-part composite material systems. However, special provisions can be made to extend these test methods to filled material systems with more than two constituents, though not all test results can be determined in every case. 1.1.2 The procedures contained within have been designed to be particularly effective for ce...

  13. 42 CFR 493.1291 - Standard: Test report.

    Science.gov (United States)

    2010-10-01

    ... electronic system(s) in place to ensure test results and other patient-specific data are accurately and... information maintained as part of the patient's chart or medical record must be readily available to the...) Results and patient-specific data electronically reported to network or interfaced systems. (3) Manually...

  14. Simultaneous Determination of Four Anthraquinones in Polygoni Multiflori Radix with Single Reference Standard by High Performance Liquid Chromatography

    Directory of Open Access Journals (Sweden)

    Hua Yang

    2015-07-01

    Full Text Available Objective: To establish a rapid, accurate and reliable analytical method for the simultaneous determination of four major anthraquinones in Polygoni Multiflori Radix (PMR using single reference standard.

  15. Standard-C hydrogen monitoring system acceptance test procedure

    Energy Technology Data Exchange (ETDEWEB)

    Schneider, T.C.

    1994-09-02

    The primary function of the standard-C hydrogen monitoring system (SHMS) is to monitor specifically for hydrogen in the waste tank atmosphere which may also contain (but not be limited to) unknown quantities of air, nitrous oxide, ammonia, water vapor, carbon dioxide, carbon monoxide, and other gaseous constituents. The SHMS will consist of hydrogen specific monitors, a grab sampler to collect samples for laboratory analysis, a gas chromatograph, and the gas sample collection system necessary to support the operation of the instrumentation. This system will be located in a cabinet placed at the tank of interest. The purpose of this document is to demonstrate that the SHMS is constructed as intended by design.

  16. Testing the Standard Model with the Primordial Inflation Explorer

    Science.gov (United States)

    Kogut, Alan J.

    2011-01-01

    The Primordial Inflation Explorer is an Explorer-class mission to measure the gravity-wave signature of primordial inflation through its distinctive imprint on the linear polarization of the cosmic microwave background. PIXIE uses an innovative optical design to achieve background-limited sensitivity in 400 spectral channels spanning 2.5 decades in frequency from 30 GHz to 6 THz (1 cm to 50 micron wavelength). The principal science goal is the detection and characterization of linear polarization from an inflationary epoch in the early universe, with tensor-to-scalar ratio r < 10A{-3) at 5 standard deviations. The rich PIXIE data set will also constrain physical processes ranging from Big Bang cosmology to the nature of the first stars to physical conditions within the interstellar medium of the Galaxy. I describe the PIXIE instrument and mission architecture needed to detect the inflationary signature using only 4 semiconductor bolometers.

  17. Handover checklist: testing a standardization process in an Italian hospital

    Directory of Open Access Journals (Sweden)

    Ferorelli D

    2017-05-01

    Full Text Available Davide Ferorelli,1 Teresa Giandola,2 Mariangela Laterza,2 Biagio Solarino,2 Angela Pezzolla,3 Fiorenza Zotti,2 Alessandro Dell’Erba1 1Interdisciplinary Department of Medicine, 2Section of Legal Medicine, 3Department of Emergency and Organ Transplantation, University of Bari, Bari, Italy Objectives: This study aimed to standardize and rationalize the handover, a critical and essential moment in common health care practices, through the realization of an efficient and standardized checklist, which could be used daily to ensure complete, thorough and effective handover. The principal purpose of the implementation of the handover is to reduce errors due to superficial and insufficient communication.Methods: The “operative group” defined the phases to the realization of the delineated aims: at first, the direct observation and the consequent realization of a handover checklist model and then, the experimental phases (trials. The handover checklist model was used for a month and it was daily and duly completed by the doctors who took part in the trial. To prove the success of the study, three questionnaires were distributed on different occasions.Results: Analyzing the answers to the questionnaires, the importance of the handover has come to light and that for the most part, the doctors consider it an essential and irreplaceable moment in daily health care work. Moreover, it became obvious that the use of the handover checklist guaranteed a considerable improvement in the traditional handover in terms of security, completeness, care continuity and clarity. The handover checklist was completely appreciated by the majority of the participant doctors who agree with the definitive introduction of it in their unit.Conclusions: Our study indicated the consistency of the handover checklist as an instrument to implement the handover and, indirectly, to improve the quality of the care. Keywords: clinical risk management, handover checklist, health care

  18. Pulsed laser simulation of VLSI single-event effect testing study

    International Nuclear Information System (INIS)

    Xue Yuxiong; Cao Zhou Yang Shiyu; Tian Kai; Liu Shufen; Chu Nan; Cao Haining; Shang Zhi

    2008-01-01

    This paper describes a study aimed at investigating the pulsed laser simulation of Single-Event Effect (SEE) testing for VLSI Intel386EX CPU, using our laboratory LSS (laser simulation system). We have detailed SEE testing principle, testing method, testing system constituting, testing result. It validates that our laser pulses simulate may use SEE testing in VLSI, and Intel 386Ex have a large locking resistance to single event. (authors)

  19. FCNC Bs and Λb transitions: Standard model versus a single universal extra dimension scenario

    International Nuclear Information System (INIS)

    Colangelo, P.; De Fazio, F.; Ferrandes, R.; Pham, T. N.

    2008-01-01

    We study the flavor changing neutral current B s →φγ, φνν and Λ b →Λγ, Λνν transitions in the standard model and in a scenario with a single universal extra dimension. In particular, we focus on the present knowledge of the hadronic uncertainties and on possible improvements. We discuss how the measurements of these modes can be used to constrain the new parameter involved in the extra-dimensional scenario, the radius R of the extra dimension, completing the information available from B-factories. The rates of these b→s induced decays are within the reach of new experiments, such as LHCb.

  20. Pre test parametric studies on single compartment vented enclosure

    International Nuclear Information System (INIS)

    Sharma, Pavan K.; Gera, B.; Singh, R.K.; Vaze, K.K.

    2011-01-01

    Establishing a proper design fire scenario is a challenging task and essential component for conducting fire safety design of buildings. A design fire scenario is a qualitative description of a fire with time identifying key events that characterize the fire (ignition, growth, flashover, fully-developed, and decay stages of fire). Proper fire safety design requires the appropriate selection of design fires against which the performance of the building is evaluated. The selection of the design fires directly impacts all aspects of fire safety performance, including the structural fire resistance, compartmentation against fire spread, egress systems, manual or automatic detection systems, suppression systems, and smoke control. The parameters affecting design fires include, the type, amount and arrangement of combustible materials, the ventilation conditions (air supply conditions, door/window open), and size of the compartment of fire origin. A design fire is a quantitative description of the characteristics of a fire, such as heat release rate (HRR), size of fire and its rate of spread, yield of products of combustion, and hot gas temperatures. Design fires are based on fire scenarios that replicate real fires. Six Computational Fluid Dynamics (CFD) numerical simulations were conducted in order to investigate the effect of fire load on fire dynamics in a) iso corner fire configuration b) IIT Delhi single compartment of a size of 5.0 m long, 5.0 m wide and 5.0 m high with doorway opening of 1m x 3m with centre fire of size 0.5 m x 0.5m. These types of simulation are carried out for deciding about the instrumentation scheme, safety aspect, and optimization of proposed experiments for National Fire Test Facility as pretest calculations. The simulations results are summarized in various identified applied parameter which are useful in terms of understanding the complex fire dynamics, validating the numerical tolls against experiments and using them (in form of values

  1. Single event effect testing of the Intel 80386 family and the 80486 microprocessor

    International Nuclear Information System (INIS)

    Moran, A.; LaBel, K.; Gates, M.; Seidleck, C.; McGraw, R.; Broida, M.; Firer, J.; Sprehn, S.

    1996-01-01

    The authors present single event effect test results for the Intel 80386 microprocessor, the 80387 coprocessor, the 82380 peripheral device, and on the 80486 microprocessor. Both single event upset and latchup conditions were monitored

  2. Development and Testing of Recombinant Single Domain Antibodies

    Science.gov (United States)

    2010-12-31

    certain animals, such as camelids (i.e., camels , llamas) and sharks possess a class of immunoglobulins consisting of heavy-chain homodimers where...examined the binding specificity of the best pairs in non-standard matrices (such as milk and tuna fish blend) as well as buffer as a measure of their

  3. Chickadees fail standardized operant tests for octave equivalence.

    Science.gov (United States)

    Hoeschele, Marisa; Weisman, Ronald G; Guillette, Lauren M; Hahn, Allison H; Sturdy, Christopher B

    2013-07-01

    Octave equivalence occurs when an observer judges notes separated by a doubling in frequency perceptually similar. The octave appears to form the basis of pitch change in all human cultures and thus may be of biological origin. Previously, we developed a nonverbal operant conditioning test of octave generalization and transfer in humans. The results of this testing showed that humans with and without musical training perceive the octave relationship between pitches. Our goal in the current study was to determine whether black-capped chickadees, a North American songbird, perceive octave equivalence. We chose these chickadees because of their reliance on pitch in assessing conspecific vocalizations, our strong background knowledge on their pitch height perception (log-linear perception of frequency), and the phylogenetic disparity between them and humans. Compared to humans, songbirds are highly skilled at using pitch height perception to classify pitches into ranges, independent of the octave. Our results suggest that chickadees used that skill, rather than octave equivalence, to transfer the note-range discrimination from one octave to the next. In contrast, there is evidence that at least some mammals, including humans, do perceive octave equivalence.

  4. 32 CFR Attachment C to Subpart B... - Standard C-Single Scope Background Investigation Periodic Reinvestigation (SSBI-PR)

    Science.gov (United States)

    2010-07-01

    ... 32 National Defense 1 2010-07-01 2010-07-01 false Standard C-Single Scope Background Investigation Periodic Reinvestigation (SSBI-PR) C Attachment C to Subpart B of Part 147 National Defense Department of... Reinvestigation (SSBI-PR) (a) Applicability. Standard C applies to reinvestigation for; (1) Access to TOP SECRET...

  5. Correlation of single-breath count test and neck flexor muscle strength with spirometry in myasthenia gravis.

    Science.gov (United States)

    Elsheikh, Bakri; Arnold, W David; Gharibshahi, Shahram; Reynolds, Jerold; Freimer, Miriam; Kissel, John T

    2016-01-01

    Although formal spirometry is the gold standard for monitoring respiratory function in patients with myasthenia gravis (MG), such testing is often delayed or unavailable. There is a need for a simple bedside test that can accurately measure respiratory function. We conducted a prospective, cross-sectional, single-blind study in adults with acetylcholine receptor antibody positive MG. Participants performed the single breath count test (SBCT) and underwent manual muscle strength testing, and a respiratory therapist performed spirometry blinded to SBCT and strength results. Thirty-one patients, aged 57 ± 19 years participated. SBCT showed significant correlations with forced vital capacity (FVC), negative inspiratory force, and neck flexor strength (P strength (P = 0.02) but no correlation with shoulder abductor strength. These data suggest that the SBCT and neck flexor strength testing are valuable tools for bedside assessment of respiratory function in MG patients. © 2015 Wiley Periodicals, Inc.

  6. Sweat test for cystic fibrosis: Wearable sweat sensor vs. standard laboratory test.

    Science.gov (United States)

    Choi, Dong-Hoon; Thaxton, Abigail; Jeong, In Cheol; Kim, Kain; Sosnay, Patrick R; Cutting, Garry R; Searson, Peter C

    2018-03-23

    Sweat chloride testing for diagnosis of cystic fibrosis (CF) involves sweat induction, collection and handling, and measurement in an analytical lab. We have developed a wearable sensor with an integrated salt bridge for real-time measurement of sweat chloride concentration. Here, in a proof-of-concept study, we compare the performance of the sensor to current clinical practice in CF patients and healthy subjects. Sweat was induced on both forearms of 10 individuals with CF and 10 healthy subjects using pilocarpine iontophoresis. A Macroduct sweat collection device was attached to one arm and sweat was collected for 30 min and then sent for laboratory analysis. A sensor was attached to the other arm and the chloride ion concentration monitored in real time for 30 min using a Bluetooth transceiver and smart phone app. Stable sweat chloride measurements were obtained within 15 min following sweat induction using the wearable sensor. We define the detection time as the time at which the standard deviation of the real-time chloride ion concentration remained below 2 mEq/L for 5 min. The sweat volume for sensor measurements at the detection time was 13.1 ± 11.4 μL (SD), in many cases lower than the minimum sweat volume of 15 μL for conventional testing. The mean difference between sweat chloride concentrations measured by the sensor and the conventional laboratory practice was 6.2 ± 9.5 mEq/L (SD), close to the arm-to-arm variation of about 3 mEq/L. The Pearson correlation coefficient between the two measurements was 0.97 highlighting the excellent agreement between the two methods. A wearable sensor can be used to make real-time measurements of sweat chloride within 15 min following sweat induction, requiring a small sweat volume, and with excellent agreement to standard methods. Copyright © 2018 European Cystic Fibrosis Society. Published by Elsevier B.V. All rights reserved.

  7. Standard Guide for Benchmark Testing of Light Water Reactor Calculations

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This guide covers general approaches for benchmarking neutron transport calculations in light water reactor systems. A companion guide (Guide E2005) covers use of benchmark fields for testing neutron transport calculations and cross sections in well controlled environments. This guide covers experimental benchmarking of neutron fluence calculations (or calculations of other exposure parameters such as dpa) in more complex geometries relevant to reactor surveillance. Particular sections of the guide discuss: the use of well-characterized benchmark neutron fields to provide an indication of the accuracy of the calculational methods and nuclear data when applied to typical cases; and the use of plant specific measurements to indicate bias in individual plant calculations. Use of these two benchmark techniques will serve to limit plant-specific calculational uncertainty, and, when combined with analytical uncertainty estimates for the calculations, will provide uncertainty estimates for reactor fluences with ...

  8. Standards for measurements and testing of wind turbine power quality

    Energy Technology Data Exchange (ETDEWEB)

    Soerensen, P. [Risoe National Lab., Roskilde (Denmark); Gerdes, G.; Klosse, R.; Santjer, F. [DEWI, Wilhelmshaven (Germany); Robertson, N.; Davy, W. [NEL, Glasgow (United Kingdom); Koulouvari, M.; Morfiadakis, E. [CRES, Pikermi (Greece); Larsson, Aa. [Chalmers Univ. of Technology, Goeteborg (Sweden)

    1999-03-01

    The present paper describes the work done in power quality sub-task of the project `European Wind Turbine Testing Procedure Developments` funded by the EU SMT program. The objective of the power quality sub-task has been to make analyses and new recommendation(s) for the standardisation of measurement and verification of wind turbine power quality. The work has been organised in three major activities. The first activity has been to propose measurement procedures and to verify existing and new measurement procedures. This activity has also involved a comparison of the measurements and data processing of the participating partners. The second activity has been to investigate the influence of terrain, grid properties and wind farm summation on the power quality of wind turbines with constant rotor speed. The third activity has been to investigate the influence of terrain, grid properties and wind farm summation on the power quality of wind turbines with variable rotor speed. (au)

  9. Numerical test for single concrete armour layer on breakwaters

    OpenAIRE

    Anastasaki, E; Latham, J-P; Xiang, J

    2016-01-01

    The ability of concrete armour units for breakwaters to interlock and form an integral single layer is important for withstanding severe wave conditions. In reality, displacements take place under wave loading, whether they are small and insignificant or large and representing serious structural damage. In this work, a code that combines finite- and discrete-element methods which can simulate motion and interaction among units was used to conduct a numerical investigation. Various concrete ar...

  10. Fabrication and test of Superconducting Single Photon Detectors

    International Nuclear Information System (INIS)

    Leoni, R.; Mattioli, F.; Castellano, M.G.; Cibella, S.; Carelli, P.; Pagano, S.; Perez de Lara, D.; Ejrnaes, M.; Lisitskyi, M.P.; Esposito, E.; Cristiano, R.; Nappi, C.

    2006-01-01

    We report here on the state of our fabrication process for Superconducting Single Photon Detectors (SSPDs). We have fabricated submicrometer SSPD structures by electron beam lithography using very thin (10 nm) NbN films deposited by DC-magnetron sputtering on different substrates and at room substrate temperature. The structures show a fast optical response (risetime <500 ps limited by readout electronics) and interesting self-resetting features

  11. Standard Test Method for Determining the Linearity of a Photovoltaic Device Parameter with Respect To a Test Parameter

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2005-01-01

    1.1 This test method determines the degree of linearity of a photovoltaic device parameter with respect to a test parameter, for example, short-circuit current with respect to irradiance. 1.2 The linearity determined by this test method applies only at the time of testing, and implies no past or future performance level. 1.3 This test method applies only to non-concentrator terrestrial photovoltaic devices. 1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  12. Distortion product otoacoustic emission test performance for a priori criteria and for multifrequency audiometric standards.

    Science.gov (United States)

    Gorga, M P; Neely, S T; Dorn, P A

    1999-08-01

    1) To describe distortion product otoacoustic emission (DPOAE) test performance when a priori response criteria are applied to a large set of DPOAE data. 2) To describe DPOAE test performance when multifrequency definitions of auditory function are used. 3) To determine DPOAE test performance when a single decision regarding auditory status is made for an ear, based on DPOAE data from several frequencies. 4) To compare univariate and multivariate test performance when multifrequency gold standard definitions and response criteria are applied to DPOAE data. DPOAE and audiometric data were analyzed from 1267 ears of 806 subjects. These data were evaluated for three different frequency combinations (2, 3, 4 kHz; 2, 3, 4, 6 kHz; 1.5, 2, 3, 4, 6 kHz). DPOAE data were collected for each of the f2 frequencies listed above, using primary levels (L1/L2) of 65/55 dB SPL and a primary ratio (f2/f1) of 1.22. Sensitivity and specificity were evaluated for signal to noise ratios (SNRs) of 3, 6, and 9 dB, which are in common clinical use. In addition, test performance was evaluated using clinical decision theory, following the convention we have used in previous reports on otoacoustic emission test performance. Both univariate and multivariate analyses techniques were applied to the data. In addition to evaluating DPOAE test performance for the case when audiometric and f2 frequency were equal, multifrequency gold standards and multifrequency criterion responses were evaluated. Three new gold standards were used to assess test performance: average pure-tone thresholds, extrema thresholds that took into account both the magnitude of the loss and the number of frequencies at which hearing loss existed, and a combination of the two. These new gold standards were applied to each of the three frequency groups described above. As expected, SNR criteria of 3, 6, and 9 dB never resulted in perfect DPOAE test performance. Even the most stringent of these criteria (9 dB SNR) did not result

  13. Standard Test Methods for Measurement of Electrical Performance and Spectral Response of Nonconcentrator Multijunction Photovoltaic Cells and Modules

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 These test methods provide special techniques needed to determine the electrical performance and spectral response of two-terminal, multijunction photovoltaic (PV) devices, both cell and modules. 1.2 These test methods are modifications and extensions of the procedures for single-junction devices defined by Test Methods E948, E1021, and E1036. 1.3 These test methods do not include temperature and irradiance corrections for spectral response and current-voltage (I-V) measurements. Procedures for such corrections are available in Test Methods E948, E1021, and E1036. 1.4 These test methods may be applied to cells and modules intended for concentrator applications. 1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and ...

  14. Standard test method for determination of reference temperature, to, for ferritic steels in the transition range

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2011-01-01

    1.1 This test method covers the determination of a reference temperature, To, which characterizes the fracture toughness of ferritic steels that experience onset of cleavage cracking at elastic, or elastic-plastic KJc instabilities, or both. The specific types of ferritic steels (3.2.1) covered are those with yield strengths ranging from 275 to 825 MPa (40 to 120 ksi) and weld metals, after stress-relief annealing, that have 10 % or less strength mismatch relative to that of the base metal. 1.2 The specimens covered are fatigue precracked single-edge notched bend bars, SE(B), and standard or disk-shaped compact tension specimens, C(T) or DC(T). A range of specimen sizes with proportional dimensions is recommended. The dimension on which the proportionality is based is specimen thickness. 1.3 Median KJc values tend to vary with the specimen type at a given test temperature, presumably due to constraint differences among the allowable test specimens in 1.2. The degree of KJc variability among specimen types i...

  15. 16 CFR 1610.35 - Procedures for testing special types of textile fabrics under the standard.

    Science.gov (United States)

    2010-01-01

    ... textile fabrics under the standard. 1610.35 Section 1610.35 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION FLAMMABLE FABRICS ACT REGULATIONS STANDARD FOR THE FLAMMABILITY OF CLOTHING TEXTILES Rules and Regulations § 1610.35 Procedures for testing special types of textile fabrics under the standard. (a) Fabric...

  16. Standard tests for the characterization of roofing slate pathologies

    Directory of Open Access Journals (Sweden)

    Cárdenes, V.

    2012-06-01

    Full Text Available The pathologies formed in slate roofs are mainly due to the presence of potentially unstable minerals (iron sulfides, carbonates and organic matter. These minerals may become altered by the effect of environmental agents, once the slate roof is finished. The pathologies are mainly associated with oxidation and gypsification processes of the cited mineral phases. In this work, the potential pathologies of several Spanish roofing slates are identified, using the tests defined in the European Norms EN 12326:2005, 14147:2004 and 11597:2007.

    Las patologías que se originan en pizarra para cubiertas son debidas fundamentalmente a la presencia de materiales alterables (sulfuros de hierro, carbonatos y materia orgánica. Estos minerales pueden llegar a alterarse por efecto de los agentes medioambientales, una vez que la pizarra es puesta en obra. Las patologías están principalmente asociadas a procesos de oxidación y yesificación de las citadas fases minerales. En este trabajo se determinan las patologías potenciales de varias pizarras para cubiertas españolas, utilizando los ensayos definidos en las normas UNE-EN 12326:2005, 14147:2004 y 11597:2007.

  17. Standard test method for determination of resistance to stable crack extension under low-constraint conditions

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2006-01-01

    1.1 This standard covers the determination of the resistance to stable crack extension in metallic materials in terms of the critical crack-tip-opening angle (CTOAc), ψc and/or the crack-opening displacement (COD), δ5 resistance curve (1). This method applies specifically to fatigue pre-cracked specimens that exhibit low constraint (crack-length-to-thickness and un-cracked ligament-to-thickness ratios greater than or equal to 4) and that are tested under slowly increasing remote applied displacement. The recommended specimens are the compact-tension, C(T), and middle-crack-tension, M(T), specimens. The fracture resistance determined in accordance with this standard is measured as ψc (critical CTOA value) and/or δ5 (critical COD resistance curve) as a function of crack extension. Both fracture resistance parameters are characterized using either a single-specimen or multiple-specimen procedures. These fracture quantities are determined under the opening mode (Mode I) of loading. Influences of environment a...

  18. Recent Tests of the Standard Model with Multiboson final states at the ATLAS Detector

    CERN Document Server

    Becker, Maurice; The ATLAS collaboration

    2017-01-01

    Measurements of the cross sections of the production of two and three electroweak gauge bosons at the LHC constitute stringent tests of the electroweak sector of the Standard Model and provide a model-independent means to search for new physics at the TeV scale. The ATLAS collaboration has performed new measurements of integrated and differential cross sections of the production of heavy di-boson pairs in fully-leptonic and semi-leptonic final states at centre-of-mass energies of 8 and 13 TeV. We present in particular new measurements of WW, WZ and Z+photon cross sections in semi-leptonic or hadronic decays using standard or boosted technologies and new measurements of the inclusive and differential ZZ cross section at 13 TeV in various decay modes. In addition, the ATLAS collaboration has recently searched for the production of three W bosons or of a W boson and a photon together with a Z or W boson at a center of mass energy of 8 TeV. Moreover, the electroweak production in vector boson fusion of single W a...

  19. 78 FR 17875 - Commercial Driver's License Testing and Commercial Learner's Permit Standards

    Science.gov (United States)

    2013-03-25

    ... [Docket No. FMCSA-2007-27659] RIN 2126-AB59 Commercial Driver's License Testing and Commercial Learner's.... The 2011 final rule amended the commercial driver's license (CDL) knowledge and skills testing standards and established new minimum Federal standards for States to issue the commercial learner's permit...

  20. 77 FR 26989 - Commercial Driver's License Testing and Commercial Learner's Permit Standards

    Science.gov (United States)

    2012-05-08

    ... [Docket No. FMCSA-2007-27659] RIN 2126-AB02 Commercial Driver's License Testing and Commercial Learner's... effective on July 8, 2011. That final rule amended the commercial driver's license (CDL) knowledge and skills testing standards and established new minimum Federal standards for States to issue the commercial...

  1. Political Judgement, Freedom of Thought, and Standardized Testing: A Critical Enquiry

    Science.gov (United States)

    Schuler, Matthew Edward

    2012-01-01

    The practice of "standardized" testing has been embedded in United States federal education policy since at least the passage of the Elementary and Secondary Education Act of 1965. The roots of standardized testing in American education, grounded in Kantian "Modern Thought," can be traced to the U.S. Military Academy at…

  2. Standard testing procedures for optical fiber and unshielded twisted pair at Sandia National Laboratories

    Energy Technology Data Exchange (ETDEWEB)

    Adams, R.L.

    1993-11-01

    This document will establish a working standard for testing optical fiber and unshielded twisted pair cables included in the Lab-wide telecommunications cabling system. The purpose of these standard testing procedures is to deliver to all Sandians a reliable, low-maintenance, state-of-the-art, ubiquitous telecommunications cabling infrastructure capable of satisfying all current and future telecommunication needs.

  3. Testing single point incremental forming molds for thermoforming operations

    Science.gov (United States)

    Afonso, Daniel; de Sousa, Ricardo Alves; Torcato, Ricardo

    2016-10-01

    Low pressure polymer processing processes as thermoforming or rotational molding use much simpler molds then high pressure processes like injection. However, despite the low forces involved with the process, molds manufacturing for this operations is still a very material, energy and time consuming operation. The goal of the research is to develop and validate a method for manufacturing plastically formed sheets metal molds by single point incremental forming (SPIF) operation for thermoforming operation. Stewart platform based SPIF machines allow the forming of thick metal sheets, granting the required structural stiffness for the mold surface, and keeping the short lead time manufacture and low thermal inertia.

  4. Are single-well "push-pull" tests suitable tracer methods for aquifer characterization?

    Science.gov (United States)

    Hebig, Klaus; Zeilfelder, Sarah; Ito, Narimitsu; Machida, Isao; Scheytt, Traugott; Marui, Atsunao

    2013-04-01

    Recently, investigations were conducted for geological and hydrogeological characterisation of the sedimentary coastal basin of Horonobe (Hokkaido, Japan). Coastal areas are typical geological settings in Japan, which are less tectonically active than the mountain ranges. In Asia, and especially in Japan, these areas are often densely populated. Therefore, it is important to investigate the behaviour of solutes in such unconsolidated aquifers. In such settings sometimes only single boreholes or groundwater monitoring wells are available for aquifer testing for various reasons, e.g. depths of more than 100 m below ground level and slow groundwater velocities due to density driven flow. A standard tracer test with several involved groundwater monitoring wells is generally very difficult or even not possible at these depths. One of the most important questions in our project was how we can obtain information about chemical and hydraulic properties in such aquifers. Is it possible to characterize solute transport behaviour parameters with only one available groundwater monitoring well or borehole? A so-called "push-pull" test may be one suitable method for aquifer testing with only one available access point. In a push-pull test a known amount of several solutes including a conservative tracer is injected into the aquifer ("push") and afterwards extracted ("pull"). The measured breakthrough curve during the pumping back phase can then be analysed. This method has already been used previously with various aims, also in the recent project (e.g. Hebig et al. 2011, Zeilfelder et al. 2012). However, different test setups produced different tracer breakthrough curves. As no systematic evaluation of this aquifer tracer test method was done so far, nothing is known about its repeatability. Does the injection and extraction rate influence the shape of the breakthrough curve? Which role plays the often applied "chaser", which is used to push the test solution out from the

  5. Testing for one Generalized Linear Single Order Parameter

    DEFF Research Database (Denmark)

    Ellegaard, Niels Langager; Christensen, Tage Emil; Dyre, Jeppe

    work the order parameter may be chosen to have a non-exponential relaxation. The model predictions contradict the general consensus of the properties of viscous liquids in two ways: (i) The model predicts that following a linear isobaric temperature step, the normalized volume and entalpy relaxation......We examine a linear single order parameter model for thermoviscoelastic relaxation in viscous liquids, allowing for a distribution of relaxation times. In this model the relaxation of volume and entalpy is completely described by the relaxation of one internal order parameter. In contrast to prior...... functions are identical. This assumption conflicts with some (but not all) reports, utilizing the Tool-Narayanaswamy formalism to extrapolate from non-linear measurements to the linear regime. (ii) The model predicts that the theoretical "linear Prigogine-Defay" ratio is one. This ratio has never been...

  6. Evaluating the "TOEFL Junior"® Standard Test as a Measure of Progress for Young English Language Learners. Research Report. ETS RR-15-22

    Science.gov (United States)

    Gu, Lin; Lockwood, John; Powers, Donald E.

    2015-01-01

    Standardized tests are often designed to provide only a snapshot of test takers' knowledge, skills, or abilities at a single point in time. Sometimes, however, they are expected to serve more demanding functions, one of them is assessing change in knowledge, skills, or ability over time because of learning effects.The latter is the case for the…

  7. Standard test method for ball punch deformation of metallic sheet material

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This test method covers the procedure for conducting the ball punch deformation test for metallic sheet materials intended for forming applications. The test applies to specimens with thicknesses between 0.008 and 0.080 in. (0.20 and 2.00 mm). 1.2 The values stated in inch–pound units are to be regarded as the standard. Note 1—The ball punch deformation test is intended to replace the Olsen cup test by standardizing many of the test parameters that previously have been left to the discretion of the testing laboratory. Note 2—The modified Erichsen test has been standardized in Europe. The main differences between the ball punch deformation test and the Erichsen test are the diameters of the penetrator and the dies. Erichsen cup heights are given in SI units. 1.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.4 This standard does...

  8. Consequences of different diagnostic "gold standards" in test accuracy research: Carpal Tunnel Syndrome as an example.

    Science.gov (United States)

    Bachmann, Lucas M; Jüni, Peter; Reichenbach, Stephan; Ziswiler, Hans-Rudolf; Kessels, Alfons G; Vögelin, Esther

    2005-08-01

    Test accuracy studies assume the existence of a well-defined illness definition and clear-cut diagnostic gold standards or reference standards. However, in clinical reality illness definitions may be vague or a mere description of a set of manifestations, mostly clinical signs and symptoms. This can lead to disagreements among experts about the correct classification of an illness and the adequate reference standard. Using data from a diagnostic accuracy study in carpal tunnel syndrome, we explored the impact of different definitions on the estimated test accuracy and found that estimated test performance characteristics varied considerably depending on the chosen reference standard. In situations without a clear-cut illness definition, randomized controlled trials may be preferable to test accuracy studies for the evaluation of a novel test. These studies do not determine the diagnostic accuracy, but the clinical impact of a novel test on patient management and outcome.

  9. Dynamic tensile test of single PET textile cables

    Directory of Open Access Journals (Sweden)

    Pasco F.

    2012-08-01

    Full Text Available The tyres conception involves for certain applications, the use of textile cables as reinforcement. During its use, the tyre undergoes temperatures variations and dynamic loading rates. The consideration of these conditions during the numeric simulations requires the knowledge of the sensitivity of the mechanical behaviour to loading rate and temperature. In this paper, we developed an experimental methodology for testing textile cable up to high strain rate. The main difficulty of testing cables is the optimization of cable fixing on the machine. For that purpose, we adapted the solution of fixing by progressive binding already used in quasi-static, while taking into account constraints inherent to high strain tests. Firstly, the mass of grips was decreased in order to get force signal less sensitive to grips inertia. The method was developed on a high speed hydraulic machine equipped with a thermal enclosure. The investigated temperatures and strain rates range from room temperature to 373 ∘K (100 ∘C and from 0,01 to 100/s, respectively. In addition, the hydraulic machine was equipped with a high speed video camera. The obtained images were analysed by a tracking technique to measure the average strain in the cable (from 50 to 20000 f/s.

  10. Result of standard patch test in patients suspected of having allergic contact dermatitis.

    Science.gov (United States)

    Wongpiyabovorn, Jongkonnee; Puvabanditsin, Porntip

    2005-09-01

    Contact dermatitis is a common skin disease. Disease was diagnosed by a history of contact substance together with geographic distribution of lesion. Up till now, standard patch test is one of the most reliable test to identify and confirm causative agent of allergic contact dermatitis. To determine the rate of positive standard patch test and to identify the common allergen of contact dermatitis in Thailand, we performed the standard patch test in 129 patients, suspected having allergic contact dermatitis at Department of Dermatology, King Chulalongkorn Memorial Hospital, Thailand from June 1, 2003 to September 1, 2004. The rate of positive standard patch test is 59.7% (n = 77/129). The most 3 common positive allergens were nickel sulfate (18.60%), cobalt chloride (17.05%) and fragrance mix (14.73%), respectively. The chance of positive standard patch test significantly correlated with sex (woman), initial diagnosis as contact dermatitis and history of house-worker (p = 0.017, p = 0.005 and p = 0.023, respectively). Whereas, there were no significant correlation between the chance of positive standard patch test and age of patient, location of lesion, history of recurrence, history of atopy, history of drug and food allergy. In addition, history of metal allergy significantly correlated with the chance of positive nickel sulfate or cobalt chloride in standard patch test (p = 0.017). In conclusion, this study demonstrated the prevalence of causative allergen of contact dermatitis in Thai patients using that standard patch test. Moreover, our data shown that the chance positive standard patch test was greater in patient, who were women or initial diagnosed as contact dermatitis or had history of houseworker or history of metal allergy.

  11. Injection molded nanofluidic chips: Fabrication method and functional tests using single-molecule DNA experiments

    DEFF Research Database (Denmark)

    Utko, Pawel; Persson, Karl Fredrik; Kristensen, Anders

    2011-01-01

    We demonstrate that fabrication of nanofluidic systems can be greatly simplified by injection molding of polymers. We functionally test our devices by single-molecule DNA experiments in nanochannels.......We demonstrate that fabrication of nanofluidic systems can be greatly simplified by injection molding of polymers. We functionally test our devices by single-molecule DNA experiments in nanochannels....

  12. 76 FR 34801 - Petition for Modification of Single Car Air Brake Test Procedures

    Science.gov (United States)

    2011-06-14

    ... reference in 49 CFR 232.305) is intended for freight cars with automatic brake systems that are...] Petition for Modification of Single Car Air Brake Test Procedures In accordance with Part 232 of Title 49... Railroad Administration (FRA) grant a modification of the single car air brake test procedures as...

  13. A single sample GnRHa stimulation test in the diagnosis of precocious puberty

    Directory of Open Access Journals (Sweden)

    Yazdani Parvin

    2012-07-01

    Full Text Available Abstract Context Gonadotropin-releasing hormone (GnRH has been the standard test for diagnosing central precocious puberty. Because GnRH is no longer available, GnRH analogues (GnRHa are now used. Random LH concentration, measured by the third-generation immunochemiluminometric assay, is a useful screening tool for central precocious puberty. However, GnRHa stimulation test should be considered, when a basal LH measurement is inconclusive. However optimal sampling times for luteinizing hormone (LH have yet to be established. Purpose To determine the appropriate sampling time for LH post leuprolide challenge. Methods A retrospective analysis of multi-sample GnRHa stimulation tests performed in 155 children (aged 1–9 years referred for precocious puberty to Texas Children’s Hospital. After 20 mcg/kg of SQ leuprolide acetate, samples were obtained at 0, 1, 3, and 6 hours. Results Of 71 children with clinical evidence of central precocious puberty, fifty nine children had a peak LH >5 mIU/mL. 52 (88% of these responders had positive responses at 1 hour (95% CI is 80–96%, whereas all 59 children (100% had a peak LH response >5 mIU/mL at 3 hours (95% CI is 94-100%, P = 0.005. Conclusions A single serum LH sample collected 3 hours post GnRHa challenge is the optimal sample to establish the diagnosis of central precocious puberty.

  14. Standard Test Method for Testing Polymeric Seal Materials for Geothermal and/or High Temperature Service Under Sealing Stress

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1985-01-01

    1.1 This test method covers the initial evaluation of (screening) polymeric materials for seals under static sealing stress and at elevated temperatures. 1.2 This test method applies to geothermal service only if used in conjunction with Test Method E 1068. 1.3 The test fluid is distilled water. 1.4 The values stated in SI units are to be regarded as the standard. The values in parentheses are for information only. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  15. Standard and prototype tests of hotwater- and steam-valves for nuclear power stations

    International Nuclear Information System (INIS)

    Dernbach, B.

    1977-11-01

    More than 150 standard and prototype valves have been tested in a special valve test facility (VTF) for reactor valve tests under working conditions. Approximately 85% of the valves performed well for the given task, in some cases however only after numerous improvements jointly done with the manufactures; 15% turned out to be unserviceable. (orig.) [de

  16. Non-invasive measurement of adrenal response after standardized exercise tests in prepubertal children

    NARCIS (Netherlands)

    Heijsman, Sigrid M.; Koers, Nicoline F.; Bocca, Gianni; van der Veen, Betty S.; Appelhof, Maaike; Kamps, Arvid W. A.

    Objective: To determine the feasibility of non-invasive evaluation of adrenal response in healthy prepubertal children by standardized exercise tests. Methods: On separate occasions, healthy prepubertal children performed a submaximal cycling test, a maximal cycling test, and a 20-m shuttle-run

  17. Standard Setting in Specific-Purpose Language Testing: What Can a Qualitative Study Add?

    Science.gov (United States)

    Manias, Elizabeth; McNamara, Tim

    2016-01-01

    This paper explores the views of nursing and medical domain experts in considering the standards for a specific-purpose English language screening test, the Occupational English Test (OET), for professional registration for immigrant health professionals. Since individuals who score performances in the test setting are often language experts…

  18. Development of Proposed Standards for Testing Solar Collectors and Thermal Storage Devices. NBS Technical Note 899.

    Science.gov (United States)

    Hill, James E.; And Others

    A study has been made at the National Bureau of Standards of the different techniques that are or could be used for testing solar collectors and thermal storage devices that are used in solar heating and cooling systems. This report reviews the various testing methods and outlines a recommended test procedure, including apparatus and…

  19. High-Stakes Standardized Testing & Marginalized Youth: An Examination of the Impact on Those Who Fail

    Science.gov (United States)

    Kearns, Laura-Lee

    2011-01-01

    This study examines the impact of high-stakes, large-scale, standardized literacy testing on youth who have failed the Ontario Secondary School Literacy Test. Interviews with youth indicate that the unintended impact of high-stakes testing is more problematic than policy makers and educators may realize. In contrast to literacy policy's aims to…

  20. Standardized tests of handwriting readiness: a systematic review of the literature

    NARCIS (Netherlands)

    Hartingsveldt, M.J. van; Groot, I.J.M. de; Aarts, P.B.M.; Nijhuis-Van der Sanden, M.W.G.

    2011-01-01

    AIM: To establish if there are psychometrically sound standardized tests or test items to assess handwriting readiness in 5- and 6-year-old children on the levels of occupations activities/tasks and performance. METHOD: Electronic databases were searched to identify measurement instruments. Tests

  1. Standardized Tests of Handwriting Readiness: A Systematic Review of the Literature

    Science.gov (United States)

    van Hartingsveldt, Margo J.; de Groot, Imelda J. M.; Aarts, Pauline B. M.; Nijhuis-van der Sanden, Maria W. G.

    2011-01-01

    Aim: To establish if there are psychometrically sound standardized tests or test items to assess handwriting readiness in 5- and 6-year-old children on the levels of occupations activities/tasks and performance. Method: Electronic databases were searched to identify measurement instruments. Tests were included in a systematic review if: (1)…

  2. Test procedures and instructions for single shell tank saltcake cesium removal with crystalline silicotitanate

    Energy Technology Data Exchange (ETDEWEB)

    Duncan, J.B.

    1997-01-07

    This document provides specific test procedures and instructions to implement the test plan for the preparation and conduct of a cesium removal test, using Hanford Single Shell Tank Saltcake from tanks 24 t -BY- I 10, 24 1 -U- 108, 24 1 -U- 109, 24 1 -A- I 0 1, and 24 t - S-102, in a bench-scale column. The cesium sorbent to be tested is crystalline siticotitanate. The test plan for which this provides instructions is WHC-SD-RE-TP-024, Hanford Single Shell Tank Saltcake Cesium Removal Test Plan.

  3. Test Anxiety and a High-Stakes Standardized Reading Comprehension Test: A Behavioral Genetics Perspective

    Science.gov (United States)

    Wood, Sarah G.; Hart, Sara A.; Little, Callie W.; Phillips, Beth M.

    2016-01-01

    Past research suggests that reading comprehension test performance does not rely solely on targeted cognitive processes such as word reading, but also on other nontarget aspects such as test anxiety. Using a genetically sensitive design, we sought to understand the genetic and environmental etiology of the association between test anxiety and…

  4. ERS technical standard on bronchial challenge testing : General considerations and performance of methacholine challenge tests

    NARCIS (Netherlands)

    Coates, Allan L.; Wanger, Jack; Cockcroft, Donald W.; Culver, Bruce H.; Carlsen, Kai-Hakon; Diamant, Zuzana; Gauvreau, Gail; Hall, Graham L.; Hallstrand, Teal S.; Horvath, Ildiko; de Jongh, Frans H. C.; Joos, Guy; Kaminsky, David A.; Laube, Beth L.; Leuppi, Joerg D.; Sterk, Peter J.

    This international task force report updates general considerations for bronchial challenge testing and the performance of the methacholine challenge test. There are notable changes from prior recommendations in order to accommodate newer delivery devices. Rather than basing the test result upon a

  5. ERS technical standard on bronchial challenge testing: general considerations and performance of methacholine challenge tests

    NARCIS (Netherlands)

    Coates, Allan L.; Wanger, Jack; Cockcroft, Donald W.; Culver, Bruce H.; Diamant, Zuzana; Gauvreau, Gail; Hall, Graham L.; Hallstrand, Teal S.; Horvath, Ildiko; de Jongh, Frans H. C.; Joos, Guy; Kaminsky, David A.; Laube, Beth L.; Leuppi, Joerg D.; Sterk, Peter J.

    2017-01-01

    This international task force report updates general considerations for bronchial challenge testing and the performance of the methacholine challenge test. There are notable changes from prior recommendations in order to accommodate newer delivery devices. Rather than basing the test result upon a

  6. Standard Errors and Confidence Intervals of Norm Statistics for Educational and Psychological Tests.

    Science.gov (United States)

    Oosterhuis, Hannah E M; van der Ark, L Andries; Sijtsma, Klaas

    2016-11-14

    Norm statistics allow for the interpretation of scores on psychological and educational tests, by relating the test score of an individual test taker to the test scores of individuals belonging to the same gender, age, or education groups, et cetera. Given the uncertainty due to sampling error, one would expect researchers to report standard errors for norm statistics. In practice, standard errors are seldom reported; they are either unavailable or derived under strong distributional assumptions that may not be realistic for test scores. We derived standard errors for four norm statistics (standard deviation, percentile ranks, stanine boundaries and Z-scores) under the mild assumption that the test scores are multinomially distributed. A simulation study showed that the standard errors were unbiased and that corresponding Wald-based confidence intervals had good coverage. Finally, we discuss the possibilities for applying the standard errors in practical test use in education and psychology. The procedure is provided via the R function check.norms, which is available in the mokken package.

  7. NEPP Update of Independent Single Event Upset Field Programmable Gate Array Testing

    Science.gov (United States)

    Berg, Melanie; Label, Kenneth; Campola, Michael; Pellish, Jonathan

    2017-01-01

    This presentation provides a NASA Electronic Parts and Packaging (NEPP) Program update of independent Single Event Upset (SEU) Field Programmable Gate Array (FPGA) testing including FPGA test guidelines, Microsemi RTG4 heavy-ion results, Xilinx Kintex-UltraScale heavy-ion results, Xilinx UltraScale+ single event effect (SEE) test plans, development of a new methodology for characterizing SEU system response, and NEPP involvement with FPGA security and trust.

  8. Evaluation of standardized test methods to characterize fiber reinforced cement composites

    DEFF Research Database (Denmark)

    Paegle, Ieva; Fischer, Gregor

    2011-01-01

    This paper describes an investigation of standardized test methods to characterize fiber reinforced cementitious composites in terms of their behavior under flexural loading and its relation to their tensile stress-deformation response. Flexural testing and derivation of the tensile stress......-deformation response are preferred in standardized testing of Fiber Reinforced Cement Composites (FRCC) over the direct assessment of the tensile behavior because of the more convenient test setup and ease of specimen preparation. Four-point bending tests were carried out to evaluate the flexural response of FRCC...... and their results are compared to data obtained from direct tensile testing. The details of the formation of cracking are an important underlying assumption in the standardized evaluation procedures as well as in the established correlation models between flexural and tensile behavior. This detail has been...

  9. First indirect x-ray imaging tests with an 88-mm diameter single crystal

    Energy Technology Data Exchange (ETDEWEB)

    Lumpkin, A. H. [Fermilab; Macrander, A. T. [Argonne

    2017-02-01

    Using the 1-BM-C beamline at the Advanced Photon Source (APS), we have performed the initial indirect x - ray imaging point-spread-function (PSF) test of a unique 88-mm diameter YAG:Ce single crystal of only 100 - micron thickness. The crystal was bonded to a fiber optic plat e (FOP) for mechanical support and to allow the option for FO coupling to a large format camera. This configuration resolution was compared to that of self - supported 25-mm diameter crystals, with and without an Al reflective coating. An upstream monochromator was used to select 17-keV x-rays from the broadband APS bending magnet source of synchrotron radiation. The upstream , adjustable Mo collimators were then used to provide a series of x-ray source transverse sizes from 200 microns down to about 15-20 microns (FWHM) at the crystal surface. The emitted scintillator radiation was in this case lens coupled to the ANDOR Neo sCMOS camera, and the indirect x-ray images were processed offline by a MATLAB - based image processing program. Based on single Gaussian peak fits to the x-ray image projected profiles, we observed a 10.5 micron PSF. This sample thus exhibited superior spatial resolution to standard P43 polycrystalline phosphors of the same thickness which would have about a 100-micron PSF. Lastly, this single crystal resolution combined with the 88-mm diameter makes it a candidate to support future x-ray diffraction or wafer topography experiments.

  10. 78 FR 24289 - Aviation Rulemaking Advisory Committee (ARAC) Airman Testing Standards and Training Working Group...

    Science.gov (United States)

    2013-04-24

    ... personal information the commenter provides. Using the search function of the docket Web site, anyone can... Information; Industry-Led Changes to FAA Airman Testing Standards and Training (2) Draft PRIVATE PILOT...

  11. Standard Practice for Dosimetry of Proton Beams for use in Radiation Effects Testing of Electronics

    International Nuclear Information System (INIS)

    McMahan, Margaret A.; Blackmore, Ewart; Cascio, Ethan W.; Castaneda, Carlos; von Przewoski, Barbara; Eisen, Harvey

    2008-01-01

    Representatives of facilities that routinely deliver protons for radiation effect testing are collaborating to establish a set of standard best practices for proton dosimetry. These best practices will be submitted to the ASTM International for adoption

  12. Standard Practice for Dosimetry of Proton Beams for use in Radiation Effects Testing of Electronics

    Energy Technology Data Exchange (ETDEWEB)

    McMahan, Margaret A.; Blackmore, Ewart; Cascio, Ethan W.; Castaneda, Carlos; von Przewoski, Barbara; Eisen, Harvey

    2008-07-25

    Representatives of facilities that routinely deliver protons for radiation effect testing are collaborating to establish a set of standard best practices for proton dosimetry. These best practices will be submitted to the ASTM International for adoption.

  13. Epidemiological cut-off values for Flavobacterium psychrophilum MIC data generated by a standard test protocol

    DEFF Research Database (Denmark)

    Smith, P.; Endris, R.; Kronvall, G.

    2016-01-01

    Epidemiological cut-off values were developed for application to antibiotic susceptibility data for Flavobacterium psychrophilum generated by standard CLSI test protocols. The MIC values for ten antibiotic agents against Flavobacterium psychrophilum were determined in two laboratories. For five a...

  14. The effects of isolated single umbilical artery on first and second trimester aneuploidy screening test parameters.

    Science.gov (United States)

    Tulek, Firat; Kahraman, Alper; Taskin, Salih; Ozkavukcu, Esra; Soylemez, Feride

    2015-04-01

    Reliability of first and second trimester screening tests largely depends on accurate estimation of maternal serum marker values. Reduced reliability could lead redundant invasive tests or misdiagnosis. Adjustments of serum marker values for confounding factors like insulin-dependent diabetes, maternal weight or maternal rhesus status are essential. We aimed to investigate whether isolated single umbilical artery alters first and second trimester test parameters or not. Routine detailed obstetric ultrasonographies performed were retrospectively screened for this study. Among spontaneously conceived singleton pregnancies, women who were found to have single umbilical artery without any additional structural anomalies or aneuploidies were selected. First and second trimester screening test results were accessible for 98 and 102 of the cases with isolated single umbilical artery, respectively. Among first trimester screening test parameters, PAPP-A (pregnancy-associated plasma protein A) MoMs were found significantly higher in isolated single umbilical artery group. AFP MoMs were found significantly elevated in isolated single umbilical artery group in second trimester quadruple tests. Existence of single umbilical artery could alter the estimation of MoM values of maternal serum markers. Reliability of prenatal screening tests could be improved by adjusting these parameters in accordance with isolated single umbilical artery.

  15. Standard Test Method for Saltwater Pressure Immersion and Temperature Testing of Photovoltaic Modules for Marine Environments

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This test method provides a procedure for determining the ability of photovoltaic modules to withstand repeated immersion or splash exposure by seawater as might be encountered when installed in a marine environment, such as a floating aid-to-navigation. A combined environmental cycling exposure with modules repeatedly submerged in simulated saltwater at varying temperatures and under repetitive pressurization provides an accelerated basis for evaluation of aging effects of a marine environment on module materials and construction. 1.2 This test method defines photovoltaic module test specimens and requirements for positioning modules for test, references suitable methods for determining changes in electrical performance and characteristics, and specifies parameters which must be recorded and reported. 1.3 This test method does not establish pass or fail levels. The determination of acceptable or unacceptable results is beyond the scope of this test method. 1.4 The values stated in SI units are to be ...

  16. Standard test method for conducting drop-weight test to determine nil-ductility transition temperature of ferritic steels

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2006-01-01

    1.1 This test method covers the determination of the nil-ductility transition (NDT) temperature of ferritic steels, 5/8 in. (15.9 mm) and thicker. 1.2 This test method may be used whenever the inquiry, contract, order, or specification states that the steels are subject to fracture toughness requirements as determined by the drop-weight test. 1.3 The values stated in inch-pound units are to be regarded as the standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  17. Single cycle to failure in bending of three standard and five locking plates and plate constructs.

    Science.gov (United States)

    Blake, C A; Boudrieau, R J; Torrance, B S; Tacvorian, E K; Cabassu, J B; Gaudette, G R; Kowaleski, M P

    2011-01-01

    To evaluate the biomechanical properties of standard and locking plates in bending. We hypothesised that titanium (Ti) constructs would have the greatest deformation and that String of Pearl (SOP) constructs would have the greatest strength and stiffness, and would behave differently compared to plates alone. Dynamic compression plates (DCP), stainless steel (SS) limited contact (LC)-DCP®, Ti LC-DCP, locking compression plates (LCP), 10 mm and 11 mm advanced locking plate system (ALPS 10 / 11), SOP and Fixin plates were evaluated individually and as constructs applied to a validated bone model simulating a bridging osteosynthesis. Bending stiffness and strength were compared using one-way ANOVA with post hoc Tukey, and unpaired t-test (p <0.05). The SOP plates had significantly greater stiffness than all other plates; Ti LC-DCP, ALPS 10 and Fixin plates had significantly lower stiffness than all other plates. The SOP constructs had the highest mean bending stiffness, and strength that was significantly different from only the Ti LC-DCP, ALPS 10 and Fixin constructs. The ALPS 10 constructs had the lowest mean bending stiffness, and strength that was significantly different from only ALPS 11 and SOP constructs. Comparison of bending structural stiffness of plates versus constructs showed a significant difference in all plate pairs except for the DCP and ALPS 10. Due to differing plate construct properties inherent to these diverse implant systems, identical approaches to fracture management and plate application cannot be applied.

  18. Evaluation procedures for single axis sinusoidal test to design spectrum requirements

    International Nuclear Information System (INIS)

    Sun, P.C.; Javid, A.

    1983-01-01

    Two simple procedures are provided in this paper for the purpose of evaluating the adequacy of a single frequency single axis test. For the purpose of evaluating the adequacy of single frequency test to meet broad-band response spectrum requirements, the proposed procedure is based on the equivalence of maximum response of a dynamic system when it is subjected to either type of design input. The required information used for the evaluation is usually recorded and available in the test report. This procedure is applicable to systems with or without closely-spaced modes. When evaluating against broad-band design spectra and multi-axes requirements, an empirical procedure is proposed and it has been found conservative. These two proposed procedures provide a quick assessment on the adequacy of a single frequency test performed earlier. The use of these procedures may eliminate the need of expensive and time consuming equipment re-testing. (orig./HP)

  19. Comparison of Size Modulation Standard Automated Perimetry and Conventional Standard Automated Perimetry with a 10-2 Test Program in Glaucoma Patients.

    Science.gov (United States)

    Hirasawa, Kazunori; Takahashi, Natsumi; Satou, Tsukasa; Kasahara, Masayuki; Matsumura, Kazuhiro; Shoji, Nobuyuki

    2017-08-01

    This prospective observational study compared the performance of size modulation standard automated perimetry with the Octopus 600 10-2 test program, with stimulus size modulation during testing, based on stimulus intensity and conventional standard automated perimetry, with that of the Humphrey 10-2 test program in glaucoma patients. Eighty-seven eyes of 87 glaucoma patients underwent size modulation standard automated perimetry with Dynamic strategy and conventional standard automated perimetry using the SITA standard strategy. The main outcome measures were global indices, point-wise threshold, visual defect size and depth, reliability indices, and test duration; these were compared between size modulation standard automated perimetry and conventional standard automated perimetry. Global indices and point-wise threshold values between size modulation standard automated perimetry and conventional standard automated perimetry were moderately to strongly correlated (p 33.40, p modulation standard automated perimetry than with conventional standard automated perimetry, but the visual-field defect size was smaller (p modulation-standard automated perimetry than on conventional standard automated perimetry. The reliability indices, particularly the false-negative response, of size modulation standard automated perimetry were worse than those of conventional standard automated perimetry (p modulation standard automated perimetry than with conventional standard automated perimetry (p = 0.02). Global indices and the point-wise threshold value of the two testing modalities correlated well. However, the potential of a large stimulus presented at an area with a decreased sensitivity with size modulation standard automated perimetry could underestimate the actual threshold in the 10-2 test protocol, as compared with conventional standard automated perimetry.

  20. Administration of Standardized Competency Tests: Does the Testing Environment Make a Difference?

    Science.gov (United States)

    Wongbundhit, Yuwadee

    1996-01-01

    To relieve overcrowded, distracting, and uncomfortable testing conditions, the Dade County (Florida) Public Schools began administering the High School Competency Test on two successive Saturdays, instead of on school days. Classrooms were used, and students received free breakfasts and lunches. The new arrangement improved student performance and…

  1. Linear shrinkage test: justification for its reintroduction as a standard South African test method

    CSIR Research Space (South Africa)

    Sampson, LR

    2009-06-04

    Full Text Available Several problems with the linear shrinkage test specified in Method A4 of the THM 1 1979 were addressed as part of this investigation in an effort to improve the alleged poor reproducibility of the test and justify its reintroduction into THM 1. A...

  2. A standardization of the physical tests for external irradiation measuring detectors

    International Nuclear Information System (INIS)

    1977-05-01

    This report is the result of a standardization work, realized within the Radioprotection Services of the A.E.C., of the physical tests for dectors measuring external irradiations. Among the various tests mentionned, calibration and the establishment of the relative spectral response are treated in details. As far as calibration is concerned, the standardization refers to: the reference detector, the reference radiation source, the installation and calibration procedure. As for the relative spectral response the standardization refers to: the reference detector, the radiation sources to be used. High flux detectors and those for pulse electromagnetic radiations are also dealt with [fr

  3. Standard Test Method for Gel Time of Carbon Fiber-Epoxy Prepreg

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1999-01-01

    1.1 This test method covers the determination of gel time of carbon fiber-epoxy tape and sheet. The test method is suitable for the measurement of gel time of resin systems having either high or low viscosity. 1.2 The values stated in SI units are to be regarded as standard. The values in parentheses are for reference only. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  4. Standard Test Method for Measuring Heat Flux Using a Water-Cooled Calorimeter

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2005-01-01

    1.1 This test method covers the measurement of a steady heat flux to a given water-cooled surface by means of a system energy balance. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  5. Standard test method for uranium analysis in natural and waste water by X-ray fluorescence

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2004-01-01

    1.1 This test method applies for the determination of trace uranium content in waste water. It covers concentrations of U between 0.05 mg/L and 2 mg/L. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  6. Standard test method for laboratory evaluation of magnesium sacrificial anode test specimens for underground applications

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1997-01-01

    1.1 This test method covers a laboratory procedure that measures the two fundamental performance properties of magnesium sacrificial anode test specimens operating in a saturated calcium sulfate, saturated magnesium hydroxide environment. The two fundamental properties are electrode (oxidation potential) and ampere hours (Ah) obtained per unit mass of specimen consumed. Magnesium anodes installed underground are usually surrounded by a backfill material that typically consists of 75 % gypsum (CaSO4·2H2O), 20 % bentonite clay, and 5 % sodium sulfate (Na2SO4). The calcium sulfate, magnesium hydroxide test electrolyte simulates the long term environment around an anode installed in the gypsum-bentonite-sodium sulfate backfill. 1.2 This test method is intended to be used for quality assurance by anode manufacturers or anode users. However, long term field performance properties may not be identical to property measurements obtained using this laboratory test. Note 1—Refer to Terminology G 15 for terms used ...

  7. Test Standard Developed for Determining the Slow Crack Growth of Advanced Ceramics at Ambient Temperature

    Science.gov (United States)

    Choi, Sung R.; Salem, Jonathan A.

    1998-01-01

    The service life of structural ceramic components is often limited by the process of slow crack growth. Therefore, it is important to develop an appropriate testing methodology for accurately determining the slow crack growth design parameters necessary for component life prediction. In addition, an appropriate test methodology can be used to determine the influences of component processing variables and composition on the slow crack growth and strength behavior of newly developed materials, thus allowing the component process to be tailored and optimized to specific needs. At the NASA Lewis Research Center, work to develop a standard test method to determine the slow crack growth parameters of advanced ceramics was initiated by the authors in early 1994 in the C 28 (Advanced Ceramics) committee of the American Society for Testing and Materials (ASTM). After about 2 years of required balloting, the draft written by the authors was approved and established as a new ASTM test standard: ASTM C 1368-97, Standard Test Method for Determination of Slow Crack Growth Parameters of Advanced Ceramics by Constant Stress-Rate Flexural Testing at Ambient Temperature. Briefly, the test method uses constant stress-rate testing to determine strengths as a function of stress rate at ambient temperature. Strengths are measured in a routine manner at four or more stress rates by applying constant displacement or loading rates. The slow crack growth parameters required for design are then estimated from a relationship between strength and stress rate. This new standard will be published in the Annual Book of ASTM Standards, Vol. 15.01, in 1998. Currently, a companion draft ASTM standard for determination of the slow crack growth parameters of advanced ceramics at elevated temperatures is being prepared by the authors and will be presented to the committee by the middle of 1998. Consequently, Lewis will maintain an active leadership role in advanced ceramics standardization within ASTM

  8. Standardization Efforts for Mechanical Testing and Design of Advanced Ceramic Materials and Components

    Science.gov (United States)

    Salem, Jonathan A.; Jenkins, Michael G.

    2003-01-01

    Advanced aerospace systems occasionally require the use of very brittle materials such as sapphire and ultra-high temperature ceramics. Although great progress has been made in the development of methods and standards for machining, testing and design of component from these materials, additional development and dissemination of standard practices is needed. ASTM Committee C28 on Advanced Ceramics and ISO TC 206 have taken a lead role in the standardization of testing for ceramics, and recent efforts and needs in standards development by Committee C28 on Advanced Ceramics will be summarized. In some cases, the engineers, etc. involved are unaware of the latest developments, and traditional approaches applicable to other material systems are applied. Two examples of flight hardware failures that might have been prevented via education and standardization will be presented.

  9. Results of patch testing with a standard series of allergens at Manipal

    Directory of Open Access Journals (Sweden)

    Shenoi Shrutakirthi

    1994-01-01

    Full Text Available The study was designed to determine the common sensitizers in allergic contact dermatitis, to evolve a standard patch test tray for screening patients at our centre and to suggest allergens for multicentric trial in India. 212 patients (65 women, 147 men were patch tested with a standard series of allergens (23 allergens of European standard series extended with lanolin, cresol and gentamycin. The frequent sensitizers observed were gentamycin (14.2%, potassium dichromate (7.1%, colophony (6.6% and fragrance mix (6.1%. No positive reactions were observed for lanolin, quaternium - 15 and mercaptomix. Our standard tray will thus consist of all the allergens of European standard series except primin along with lanolin, cresol and gentamycin. Lanolin is included despite negativity as it was found to be the commonest sensitizer among topical medications in our previous study.

  10. Results of single borehole hydraulic testing in the Mizunami Underground Research Laboratory project. Phase 2

    International Nuclear Information System (INIS)

    Daimaru, Shuji; Takeuchi, Ryuji; Onoe, Hironori; Saegusa, Hiromitsu

    2012-09-01

    This report summarize the results of the single borehole hydraulic tests of 79 sections conducted as part of the Construction phase (Phase 2) in the Mizunami Underground Research Laboratory (MIU) Project. The details of each test (test interval depth, geology, etc.) as well as the interpreted hydraulic parameters and analytical method used are presented in this report. (author)

  11. Standard test method for radiochemical determination of uranium isotopes in urine by alpha spectrometry

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2011-01-01

    1.1 This test method is applicable to the determination of uranium in urine at levels of detection dependent on sample size, count time, detector background, and tracer yield. It is designed as a screening tool for detection of possible exposure of occupational workers. 1.2 This test method is designed for 50 mL of urine. This test method does not address the sampling protocol or sample preservation methods associated with its use. 1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  12. Effect of simulated resistance, fleeing, and use of force on standardized field sobriety testing.

    Science.gov (United States)

    Ho, Jeffrey; Dawes, Donald; Nystrom, Paul; Moore, Johanna; Steinberg, Lila; Tilton, Annemarie; Miner, James

    2015-07-01

    When a law enforcement officer (LEO) stops a suspect believed to be operating (a vehicle) while impaired (OWI), the suspect may resist or flee, and the LEO may respond with force. The suspect may then undergo a Standardized Field Sobriety Test (SFST) to gauge impairment. It is not known whether resistance, fleeing, or actions of force can create an inaccurate SFST result. We examined the effect of resistance, fleeing, and force on the SFST. Human volunteers were prospectively randomized to have a SFST before and after one of five scenarios: (1) five-second conducted electrical weapon exposure; (2) 100-yard (91.4 m) sprint; (3) 45-second physical fight; (4) police dog bite with protective gear; and (5) Oleoresin Capsicum spray to the face with eyes shielded. The SFST was administered and graded by a qualified LEO. After the SFST, the volunteer entered their scenario and was then administered another SFST. Data were analyzed using descriptive statistics. SFST performance was compared before and after using chi-square tests. Fifty-seven subjects enrolled. Three received a single-point penalty during one component of the three-component SFST pre-scenario. No subject received a penalty point in any components of the SFST post-scenario (p = 0.08). This is the first human study to examine the effects of physical resistance, flight, and use of force on the SFST result. We did not detect a difference in the performance of subjects taking the SFST before and after exposure to resistance, flight, or a simulated use of force. © Australian Council for Educational Research 2014.

  13. Standard test method for ranking resistance of plastic materials to sliding wear using a block-on-ring configuration

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1997-01-01

    1.1 This test method covers a laboratory procedure to measure the resistance of plastic materials under dry sliding conditions. The test utilizes a block-on-ring geometry to rank materials according to their sliding wear characteristics under various conditions. 1.2 The test specimens are small so that they can be molded or cut from fabricated plastic parts. The test may be run at the load, velocity, and temperature which simulate the service condition. 1.3 Wear test results are reported as specific wear rates calculated from volume loss, sliding distance, and load. Materials with superior wear resistance have lower specific wear rates. 1.4 This test method allows the use of both single- and multi-station apparatus to determine the specific wear rates. 1.5 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibil...

  14. Chapter 9: options for summarizing medical test performance in the absence of a "gold standard".

    Science.gov (United States)

    Trikalinos, Thomas A; Balion, Cynthia M

    2012-06-01

    The classical paradigm for evaluating test performance compares the results of an index test with a reference test. When the reference test does not mirror the "truth" adequately well (e.g. is an "imperfect" reference standard), the typical ("naïve") estimates of sensitivity and specificity are biased. One has at least four options when performing a systematic review of test performance when the reference standard is "imperfect": (a) to forgo the classical paradigm and assess the index test's ability to predict patient relevant outcomes instead of test accuracy (i.e., treat the index test as a predictive instrument); (b) to assess whether the results of the two tests (index and reference) agree or disagree (i.e., treat them as two alternative measurement methods); (c) to calculate "naïve" estimates of the index test's sensitivity and specificity from each study included in the review and discuss in which direction they are biased; (d) mathematically adjust the "naïve" estimates of sensitivity and specificity of the index test to account for the imperfect reference standard. We discuss these options and illustrate some of them through examples.

  15. NASA Electronic Parts and Packaging Field Programmable Gate Array Single Event Effects Test Guideline Update

    Science.gov (United States)

    Berg, Melanie D.; LaBel, Kenneth A.

    2018-01-01

    The following are updated or new subjects added to the FPGA SEE Test Guidelines manual: academic versus mission specific device evaluation, single event latch-up (SEL) test and analysis, SEE response visibility enhancement during radiation testing, mitigation evaluation (embedded and user-implemented), unreliable design and its affects to SEE Data, testing flushable architectures versus non-flushable architectures, intellectual property core (IP Core) test and evaluation (addresses embedded and user-inserted), heavy-ion energy and linear energy transfer (LET) selection, proton versus heavy-ion testing, fault injection, mean fluence to failure analysis, and mission specific system-level single event upset (SEU) response prediction. Most sections within the guidelines manual provide information regarding best practices for test structure and test system development. The scope of this manual addresses academic versus mission specific device evaluation and visibility enhancement in IP Core testing.

  16. 78 FR 70349 - Proposed Revision of Policy for Incorporating New Test Standards Into the List of Appropriate...

    Science.gov (United States)

    2013-11-25

    ...) to the requirements in the replacement test standard. If OSHA's analysis shows the replacement test... standard to affected NRTLs' scopes of recognition. If OSHA's analysis shows the replacement test standard... equipment \\1\\ and materials for workplace safety purposes and to determine conformance with the test...

  17. Truck Rollover Characterization for Class-8 Tractor-Trailers Utilizing Standard Dual Tires and New-Generation Single Tires

    Energy Technology Data Exchange (ETDEWEB)

    Capps, Gary [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States). National Transportation Research Center; Knee, Bill [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States). National Transportation Research Center; Franzese, Oscar [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States). National Transportation Research Center; Pollock, Paul [Dana Corporation, Kalamazoo, MI (United States). Commercial Vehicle Systems Division; Coleman, Daniel [Dana Corporation, Kalamazoo, MI (United States). Commercial Vehicle Systems Division; Janajreh, Ibrahim [Michelin Americas Research and Development Corporation, Greenville, SC (United States); Haas, Steven [Michelin Americas Research and Development Corporation, Greenville, SC (United States); Frey, Norm [Michelin Americas Research and Development Corporation, Greenville, SC (United States); Law, Harry [Clemson Univ., SC (United States). Fluor Daniel Engineering Innovation Building; Johnson, Eric [Clemson Univ., SC (United States). Fluor Daniel Engineering Innovation Building; Lawson, Robert [Clemson Univ., SC (United States). Fluor Daniel Engineering Innovation Building; Petrolino, Joe [National Transportation Research Center, Inc., Knoxville, TN (United States); Rice, Dave [National Transportation Research Center, Inc., Knoxville, TN (United States)

    2005-07-30

    The Heavy Truck Rollover Characterization Project is a major research effort conducted by the National Transportation Research Center, Inc. (NTRCI) in partnership with Oak Ridge National Laboratory (ORNL), Dana Corporation (Dana), Michelin Americas Research and Development Corporation (Michelin) and Clemson University (Clemson), under the NTRCIs Heavy Vehicle Safety Research Center (HVSRC) for the Federal Highway Administration (FHWA). ORNL provided the day-to-day management of the project. The expertise mix of this team coupled with complementary research needs and interests, and a positive can-do attitude provided an extremely positive experimental research opportunity for all involved. Furthermore, this team supplied significant and valuable resources that provided a strong positive benchmark regarding the ability to conduct research within a public-private partnership. The work conducted by this team focused on initial efforts to generate data and information on heavy truck rollover not currently available in the industry. It reflects efforts within Phases 1 and 2 of a longer-term four-phase research program. A 1999 Peterbilt 379 class-8 tractor and 2004 Wabash dry freight van trailer were the test vehicles utilized in this effort. Both were instrumented with a number of sensors to capture the dynamics of the tractor and trailer as it engaged in various testing maneuvers that included: an evasive maneuver, swept sine, constant radius, and a run-off-the-road maneuver. The run-off-the-road maneuver was discontinued because the test track could not safety accommodate such a maneuver. These maneuvers were carried out utilizing both standard dual tires and new-generation dual tires in six test series. Two test series also included the use of a wider-slider suspension. Outriggers were placed on the test vehicle to assure that an actual rollover would not occur, however, the tests were designed to generate lift-off of tires during the tests. One of the main objectives

  18. 76 FR 26853 - Commercial Driver's License Testing and Commercial Learner's Permit Standards

    Science.gov (United States)

    2011-05-09

    ... Safety Administration 49 CFR Parts 383, 384 and 385 Commercial Driver's License Testing and Commercial... Administration 49 CFR Parts 383, 384, and 385 [Docket No. FMCSA-2007-27659] RIN 2126-AB02 Commercial Driver's License Testing and Commercial Learner's Permit Standards AGENCY: Federal Motor Carrier Safety...

  19. Evaluation of a draft standard on performance specifications for health physics instrumentation: results for environmental tests

    International Nuclear Information System (INIS)

    Kenoyer, J.L.; Swinth, K.L.; Mashburn, K.R.; Selby, J.M.

    1984-06-01

    Draft ANSI Standard N42.17 on performance specifications for health physics instrumentation is currently being evaluated by the Pacific Northwest Laboratory. Evaluation is performed by testing a cross-section of currently available instruments with testing procedures based on specifications of the standard and then determining the degree of conformance to the various elements of the proposed standard. Data will be presented on the performance of a cross-section of beta-gamma survey instruments under various environmental tests. Test results that will be presented include temperature effects, humidity effects, radio frequency (r.f.) susceptibility, ambient pressure effects, vibration effects, and shock effects. Tests performed to date show that most instruments will meet the temperature, humidity, and ambient pressure tests. A large variability is noted among instruments from the same or different vendors. Preliminary r.f. susceptibility tests have shown large artificial responses at some frequencies for specific instruments. The presentation will also include a discussion of procedures used in the testing and weaknesses identified in the proposed standard

  20. An Evaluation of Standardized Tests as Tools for the Measurement of Language Development.

    Science.gov (United States)

    Roberts, Elsa

    Four tests--PPVT, ITPA, MRT, WPPSI--commonly used to measure language development in young children are evaluated by four criteria: (1) what development aspects do they claim to tap; (2) what do they actually tap; (3) what linguistic knowledge is presupposed; (4) what special problems face a non-standard English speaker. These tests are considered…

  1. Toward the establishment of standardized in vitro tests for lipid-based formulations, part 4

    DEFF Research Database (Denmark)

    Williams, Hywel D; Sassene, Philip; Kleberg, Karen

    2014-01-01

    The Lipid Formulation Classification System Consortium looks to develop standardized in vitro tests and to generate much-needed performance criteria for lipid-based formulations (LBFs). This article highlights the value of performing a second, more stressful digestion test to identify LBFs near a...

  2. Consensus based reporting standards for diagnostic test accuracy studies for paratuberculosis in ruminants.

    NARCIS (Netherlands)

    Gardner, I.A.; Nielsen, S.S.; Whittington, R.J.; Collins, M.T.; Bakker, D.; Harris, B.; Sreevatsan, S.; Lombard, J.E.; Sweeney, R.; Smith, D.R.; Gavalchin, J.; Eda, S.

    2011-01-01

    The Standards for Reporting of Diagnostic Accuracy (STARD) statement (www.stard-statement.org) was developed to encourage complete and transparent reporting of key elements of test accuracy studies in human medicine. The statement was motivated by widespread evidence of bias in test accuracy studies

  3. Toward a Qualitative Analysis of Standardized Tests Using an Information Processing Model.

    Science.gov (United States)

    Armour-Thomas, Eleanor

    The use of standardized tests and test data to detect and address differences in cognitive styles is advocated here. To this end, the paper describes the componential theory of intelligence addressed by Sternberg et. al. This theory defines the components of intelligence by function and level of generality, including: (1) metacomponents: higher…

  4. Development of a Standard Test to Assess the Resistance of Staphylococcus aureus Biofilm Cells to Disinfectants

    NARCIS (Netherlands)

    Luppens, S.B.I.; Reij, M.W.; Heijden, van der R.W.; Rombouts, F.M.; Abee, T.

    2002-01-01

    A standardized disinfectant test for Staphylococcus aureus cells in biofilms was developed. Two disinfectants, the membrane-active compound benzalkonium chloride (BAC) and the oxidizing agent sodium hypochlorite, were used to evaluate the biofilm test. S. aureus formed biofilms on glass, stainless

  5. Developing a Strategy for Using Technology-Enhanced Items in Large-Scale Standardized Tests

    Science.gov (United States)

    Bryant, William

    2017-01-01

    As large-scale standardized tests move from paper-based to computer-based delivery, opportunities arise for test developers to make use of items beyond traditional selected and constructed response types. Technology-enhanced items (TEIs) have the potential to provide advantages over conventional items, including broadening construct measurement,…

  6. Comparing the Effects of Elementary Music and Visual Arts Lessons on Standardized Mathematics Test Scores

    Science.gov (United States)

    King, Molly Elizabeth

    2016-01-01

    The purpose of this quantitative, causal-comparative study was to compare the effect elementary music and visual arts lessons had on third through sixth grade standardized mathematics test scores. Inferential statistics were used to compare the differences between test scores of students who took in-school, elementary, music instruction during the…

  7. Using Modern Test Theory to Maintain Standards in Public Qualifications in England

    Science.gov (United States)

    Wheadon, Christopher

    2013-01-01

    This paper describes how item response theory (IRT) methods of test-equating could be applied to the maintenance of public examination standards in England. IRT methods of test-equating have been sparingly applied to the main public examinations in England, namely the General Certificate of Secondary Education (GCSE), the equivalent of a school…

  8. Standard test method for determination of surface lubrication on flexible webs

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1999-01-01

    1.1 This test method has been used since 1988 as an ANSI/ISO standard test for determination of lubrication on processed photographic films. Its purpose was to determine the presence of process-surviving lubricants on photographic films. It is the purpose of this test method to expand the applicability of this test method to other flexible webs that may need lubrication for suitable performance. This test measures the breakaway (static) coefficient of friction of a metal rider on the web by the inclined plane method. The objectives of the test is to determine if a web surface has a lubricant present or not. It is not intended to assign a friction coefficient to a material. It is not intended to rank lubricants. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish ...

  9. Error analysis for duct leakage tests in ASHRAE standard 152P

    Energy Technology Data Exchange (ETDEWEB)

    Andrews, J.W.

    1997-06-01

    This report presents an analysis of random uncertainties in the two methods of testing for duct leakage in Standard 152P of the American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE). The test method is titled Standard Method of Test for Determining Steady-State and Seasonal Efficiency of Residential Thermal Distribution Systems. Equations have been derived for the uncertainties in duct leakage for given levels of uncertainty in the measured quantities used as inputs to the calculations. Tables of allowed errors in each of these independent variables, consistent with fixed criteria of overall allowed error, have been developed.

  10. Forecast of thermal-hydrological conditions and air injection test results of the single heater test at Yucca Mountain

    International Nuclear Information System (INIS)

    Birkholzer, J.T.; Tsang, Y.W.

    1996-12-01

    The heater in the Single Heater Test (SHT) in alcove 5 of the Exploratory Studies Facility (ESF) was turned on August 26, 1996. A large number of sensors are installed in the various instrumented boreholes to monitor the coupled thermal-hydrological-mechanical-chemical responses of the rock mass to the heat generated in the single heater. In this report the authors present the results of the modeling of both the heating and cooling phases of the Single Heater Test (SHT), with focus on the thermal-hydrological aspect of the coupled processes. Also in this report, the authors present simulations of air injection tests will be performed at different stages of the heating and cooling phase of the SHT

  11. A Multi-Year Plan for Research, Development, and Prototype Testing of Standard Modular Hydropower Technology

    Energy Technology Data Exchange (ETDEWEB)

    Smith, Brennan T. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Welch, Tim [U.S. Department of Energy (DOE), Washington, DC (United States).Office of Energy Efficiency and Renewable Energy (EERE); Witt, Adam M. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Stewart, Kevin M. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Lee, Kyutae [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); DeNeale, Scott T. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Bevelhimer, Mark S. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Burress, Timothy A. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Pracheil, Brenda M. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Pries, Jason L. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); O' Connor, Patrick W. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Curd, Shelaine L. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Ekici, Kivanc [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Univ. of Tennessee, Knoxville, TN (United States); Papanicolaou, Thanos [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Univ. of Tennessee, Knoxville, TN (United States); Tsakiris, Achilleas [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Univ. of Tennessee, Knoxville, TN (United States); Kutz, Benjamin [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Univ. of Tennessee, Knoxville, TN (United States); Bishop, Norm [Knight Piesold, Denver, CO (United States); McKeown, Alisha [McKeown and Associates, Moberly, MO (United States); Rabon, Daniel [U.S. Department of Energy (DOE), Washington, DC (United States).Office of Energy Efficiency and Renewable Energy (EERE); Zimmerman, Gregory P. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Uria Martinez, Rocio [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); McManamay, Ryan A. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2017-02-01

    The Multi-Year Plan for Research, Development, and Prototype Testing of Standard Modular Hydropower Technology (MYRP) presents a strategy for specifying, designing, testing, and demonstrating the efficacy of standard modular hydropower (SMH) as an environmentally compatible and cost-optimized renewable electricity generation technology. The MYRP provides the context, background, and vision for testing the SMH hypothesis: if standardization, modularity, and preservation of stream functionality become essential and fully realized features of hydropower technology, project design, and regulatory processes, they will enable previously unrealized levels of new project development with increased acceptance, reduced costs, increased predictability of outcomes, and increased value to stakeholders. To achieve success in this effort, the MYRP outlines a framework of stakeholder-validated criteria, models, design tools, testing facilities, and assessment protocols that will facilitate the development of next-generation hydropower technologies.

  12. Development of a standardized battery of performance tests for the assessment of noise stress effects

    Science.gov (United States)

    Theologus, G. C.; Wheaton, G. R.; Mirabella, A.; Brahlek, R. E.

    1973-01-01

    A set of 36 relatively independent categories of human performance were identified. These categories encompass human performance in the cognitive, perceptual, and psychomotor areas, and include diagnostic measures and sensitive performance metrics. Then a prototype standardized test battery was constructed, and research was conducted to obtain information on the sensitivity of the tests to stress, the sensitivity of selected categories of performance degradation, the time course of stress effects on each of the selected tests, and the learning curves associated with each test. A research project utilizing a three factor partially repeated analysis of covariance design was conducted in which 60 male subjects were exposed to variations in noise level and quality during performance testing. Effects of randomly intermittent noise on performance of the reaction time tests were observed, but most of the other performance tests showed consistent stability. The results of 14 analyses of covariance of the data taken from the performance of the 60 subjects on the prototype standardized test battery provided information which will enable the final development and test of a standardized test battery and the associated development of differential sensitivity metrics and diagnostic classificatory system.

  13. Measurement of reading speed with standardized texts: a comparison of single sentences and paragraphs.

    Science.gov (United States)

    Altpeter, Elke Karin; Marx, Tobias; Nguyen, Nhung Xuan; Naumann, Aline; Trauzettel-Klosinski, Susanne

    2015-08-01

    We examined the influence of text length (single sentence versus a paragraph of several sentences) on the repeatability of reading speed measurements in normal-sighted subjects. We compared reading speeds for the German versions of the Radner charts (single sentences of 14 words each) and the International Reading Speed Texts (IReST) charts (paragraphs, on average 132 words) in 30 normal-sighted elderly subjects aged 51-81 years (mean 64.5 years ± 7.2 SD). Three texts each of both lengths were read aloud in random order. The influence of text length (single sentence or paragraph) and text sample (each single text) on reading speed was calculated by a regression model and Bland-Altman analysis. Mean reading speed (words per minute) showed no significant difference for single sentences (170 wpm ± 33 SD) and paragraphs (167 wpm ±31 SD). Differences in reading speeds within one type of reading material were higher between single sentences than between paragraphs. Correlation coefficients between speeds were higher for paragraphs (r = 0.96-0.98) than for single sentences (r = 0.69-0.78). Variations between reading speeds for three texts of each length were markedly lower for paragraphs than for single sentences: (median, interquartile range [IQR]): 6.7, IQR 13.9; 3.0, IQR 8.3; -2.0, IQR 9.7 versus -8.8, IQR 29.6; 15.6, IQR 29.4; 22.7, IQR 19.4, respectively. Since reading speeds assessed with paragraphs show lower variance among texts than those for single sentences, they are better suited for repeated measurements, especially for long-term monitoring of the course of reading performance and for assessing effects of interventions in subjects with reading disorders.

  14. Harmonization of standards for parabolic trough collector testing in solar thermal power plants

    Science.gov (United States)

    Sallaberry, Fabienne; Valenzuela, Loreto; Palacin, Luis G.; Leon, Javier; Fischer, Stephan; Bohren, Andreas

    2017-06-01

    The technology of parabolic trough collectors (PTC) is used widely in concentrating Solar Power (CSP) plants worldwide. However this type of large-size collectors cannot be officially tested by an accredited laboratory and certified by an accredited certification body so far, as there is no standard adapted to its particularity, and the current published standard for solar thermal collectors are not completely applicable to them. Recently some standardization committees have been working on this technology. This paper aims to give a summary of the standardized testing methodology of large-size PTC for CSP plants, giving the physical model chosen for modeling the thermal performance of the collector in the new revision of standard ISO 9806 and the points still to be improved in the standard draft IEC 62862-3-2. In this paper, a summary of the testing validation performed on one parabolic trough collector installed in one of the test facilities at the Plataforma Solar de Almería (PSA) with this new model is also presented.

  15. Electromagnetic compatibility (EMC) standard test chamber upgrade requirements for spacecraft design verification tests

    Science.gov (United States)

    Dyer, Edward F.

    1992-01-01

    In view of the serious performance deficiencies inherent in conventional modular and welded shielding EMC test enclosures, in which multipath reflections and resonant standing waves can damage flight hardware during RF susceptibility tests, NASA-Goddard has undertaken the modification of a 20 x 24 ft modular-shielded enclosure through installation of steel panels to which ferrite tiles will be mounted with epoxy. The internally reflected RF energy will thereby be absorbed, and exterior power-line noise will be reduced. Isolation of power-line filters and control of 60-Hz ground connections will also be undertaken in the course of upgrading.

  16. Intersection tests for single marker QTL analysis can be more powerful than two marker QTL analysis

    Directory of Open Access Journals (Sweden)

    Doerge RW

    2003-06-01

    Full Text Available Abstract Background It has been reported in the quantitative trait locus (QTL literature that when testing for QTL location and effect, the statistical power supporting methodologies based on two markers and their estimated genetic map is higher than for the genetic map independent methodologies known as single marker analyses. Close examination of these reports reveals that the two marker approaches are more powerful than single marker analyses only in certain cases. Simulation studies are a commonly used tool to determine the behavior of test statistics under known conditions. We conducted a simulation study to assess the general behavior of an intersection test and a two marker test under a variety of conditions. The study was designed to reveal whether two marker tests are always more powerful than intersection tests, or whether there are cases when an intersection test may outperform the two marker approach. We present a reanalysis of a data set from a QTL study of ovariole number in Drosophila melanogaster. Results Our simulation study results show that there are situations where the single marker intersection test equals or outperforms the two marker test. The intersection test and the two marker test identify overlapping regions in the reanalysis of the Drosophila melanogaster data. The region identified is consistent with a regression based interval mapping analysis. Conclusion We find that the intersection test is appropriate for analysis of QTL data. This approach has the advantage of simplicity and for certain situations supplies equivalent or more powerful results than a comparable two marker test.

  17. Contribution of thermal–hydraulic validation tests to the standard design approval of SMART

    Directory of Open Access Journals (Sweden)

    Hyun-Sik Park

    2017-10-01

    Full Text Available Many thermal–hydraulic tests have been conducted at the Korea Atomic Energy Research Institute for verification of the SMART (System-integrated Modular Advanced ReacTor design, the standard design approval of which was issued by the Korean regulatory body. In this paper, the contributions of these tests to the standard design approval of SMART are discussed. First, an integral effect test facility named VISTA-ITL (Experimental Verification by Integral Simulation of Transients and Accidents-Integral Test Loop has been utilized to assess the TASS/SMR-S (Transient and Set-point Simulation/Small and Medium safety analysis code and confirm its conservatism, to support standard design approval, and to construct a database for the SMART design optimization. In addition, many separate effect tests have been performed. The reactor internal flow test has been conducted using the SCOP (SMART COre flow distribution and Pressure drop test facility to evaluate the reactor internal flow and pressure distributions. An ECC (Emergency Core Coolant performance test has been carried out using the SWAT (SMART ECC Water Asymmetric Two-phase choking test facility to evaluate the safety injection performance and to validate the thermal–hydraulic model used in the safety analysis code. The Freon CHF (Critical Heat Flux test has been performed using the FTHEL (Freon Thermal Hydraulic Experimental Loop facility to construct a database from the 5 × 5 rod bundle Freon CHF tests and to evaluate the DNBR (Departure from Nucleate Boiling Ratio model in the safety analysis and core design codes. These test results were used for standard design approval of SMART to verify its design bases, design tools, and analysis methodology.

  18. Introducing Vouchers and Standardized Tests for Higher Education in Russia: Expectations and Measurements

    OpenAIRE

    Osipian, Ararat

    2008-01-01

    The reform of higher education in Russia, based on standardized tests and educational vouchers, was intended to reduce inequalities in access to higher education. The initiative with the vouchers has failed and by now is already forgotten while the national test is planned to be introduced nationwide in 2009. The national test called to replace the present corrupt system of entry examinations has experienced numerous problems so far and will likely have even more problems in the future. This ...

  19. Standard Specification for Sampling Single-Phase Geothermal Liquid or Steam for Purposes of Chemical Analysis

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1983-01-01

    1.1 This specification covers the basic requirements for equipment to be used for the collection of uncontaminated and representative samples from single-phase geothermal liquid or steam. Geopressured liquids are included. See Fig 1.

  20. College of American Pathologists' laboratory standards for next-generation sequencing clinical tests.

    Science.gov (United States)

    Aziz, Nazneen; Zhao, Qin; Bry, Lynn; Driscoll, Denise K; Funke, Birgit; Gibson, Jane S; Grody, Wayne W; Hegde, Madhuri R; Hoeltge, Gerald A; Leonard, Debra G B; Merker, Jason D; Nagarajan, Rakesh; Palicki, Linda A; Robetorye, Ryan S; Schrijver, Iris; Weck, Karen E; Voelkerding, Karl V

    2015-04-01

    The higher throughput and lower per-base cost of next-generation sequencing (NGS) as compared to Sanger sequencing has led to its rapid adoption in clinical testing. The number of laboratories offering NGS-based tests has also grown considerably in the past few years, despite the fact that specific Clinical Laboratory Improvement Amendments of 1988/College of American Pathologists (CAP) laboratory standards had not yet been developed to regulate this technology. To develop a checklist for clinical testing using NGS technology that sets standards for the analytic wet bench process and for bioinformatics or "dry bench" analyses. As NGS-based clinical tests are new to diagnostic testing and are of much greater complexity than traditional Sanger sequencing-based tests, there is an urgent need to develop new regulatory standards for laboratories offering these tests. To develop the necessary regulatory framework for NGS and to facilitate appropriate adoption of this technology for clinical testing, CAP formed a committee in 2011, the NGS Work Group, to deliberate upon the contents to be included in the checklist. Results . -A total of 18 laboratory accreditation checklist requirements for the analytic wet bench process and bioinformatics analysis processes have been included within CAP's molecular pathology checklist (MOL). This report describes the important issues considered by the CAP committee during the development of the new checklist requirements, which address documentation, validation, quality assurance, confirmatory testing, exception logs, monitoring of upgrades, variant interpretation and reporting, incidental findings, data storage, version traceability, and data transfer confidentiality.

  1. IPHE Regulations Codes and Standards Working Group - Type IV COPV Round Robin Testing

    Science.gov (United States)

    Maes, M.; Starritt, L.; Zheng, J. Y.; Ou, K.; Keller, J.

    2017-01-01

    This manuscript presents the results of a multi-lateral international activity intended to understand how to execute a cycle stress test as specified in a chosen standard (GTR, SAE, ISO, EIHP...). The purpose of this work was to establish a harmonized test method protocol to ensure that the same results would be achieved regardless of the testing facility. It was found that accurate temperature measurement of the working fluid is necessary to ensure the test conditions remain within the tolerances specified. Continuous operation is possible with adequate cooling of the working fluid but this becomes more demanding if the cycle frequency increases. Recommendations for future test system design and operation are presented.

  2. Development of test practice requirements for a standard method on fracture toughness testing in the transition range

    International Nuclear Information System (INIS)

    McCabe, D.E.; Zerbst, U.; Heerens, J.

    1993-01-01

    This report covers the resolution of several issues that are relevant to the ductile to brittle transition range of structural steels. One of this issues was to compare a statistical-based weakest-link method to constraint data adjustment methods for modeling the specimen size effects on fracture toughness. Another was to explore the concept of a universal transition temperature curve shape (Master Curve). Data from a Materials Properties Council round robin activity were used to test the proposals empirically. The findings of this study are inclosed in an activity for the development of a draft standard test procedure ''Test Practice for Fracture Toughness in the Transition Range''. (orig.) [de

  3. Tests of local Lorentz invariance violation of gravity in the standard model extension with pulsars.

    Science.gov (United States)

    Shao, Lijing

    2014-03-21

    The standard model extension is an effective field theory introducing all possible Lorentz-violating (LV) operators to the standard model and general relativity (GR). In the pure-gravity sector of minimal standard model extension, nine coefficients describe dominant observable deviations from GR. We systematically implemented 27 tests from 13 pulsar systems to tightly constrain eight linear combinations of these coefficients with extensive Monte Carlo simulations. It constitutes the first detailed and systematic test of the pure-gravity sector of minimal standard model extension with the state-of-the-art pulsar observations. No deviation from GR was detected. The limits of LV coefficients are expressed in the canonical Sun-centered celestial-equatorial frame for the convenience of further studies. They are all improved by significant factors of tens to hundreds with existing ones. As a consequence, Einstein's equivalence principle is verified substantially further by pulsar experiments in terms of local Lorentz invariance in gravity.

  4. Standard test method for measurement of oxidation-reduction potential (ORP) of soil

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This test method covers a procedure and related test equipment for measuring oxidation-reduction potential (ORP) of soil samples removed from the ground. 1.2 The procedure in Section 9 is appropriate for field and laboratory measurements. 1.3 Accurate measurement of oxidation-reduction potential aids in the analysis of soil corrosivity and its impact on buried metallic structure corrosion rates. 1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  5. Standard test method for abrasiveness of ink-impregnated fabric printer ribbons and other web materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This test method covers the determination of the abrasiveness of ink-impregnated fabric printer ribbons and other web materials by means of a sliding wear test. 1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  6. Standard test method for measurement of web/roller friction characteristics

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2003-01-01

    1.1 This test method covers the simulation of a roller/web transport tribosystem and the measurement of the static and kinetic coefficient of friction of the web/roller couple when sliding occurs between the two. The objective of this test method is to provide users with web/roller friction information that can be used for process control, design calculations, and for any other function where web/roller friction needs to be known. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  7. Standard Test Method for Gravimetric Determination of Nonvolatile Residue (NVR) in Environmentally Controlled Areas for Spacecraft

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 This test method covers the determination of nonvolatile residue (NVR) fallout in environmentally controlled areas used for the assembly, testing, and processing of spacecraft. 1.2 The NVR of interest is that which is deposited on sampling plate surfaces at room temperature: it is left to the user to infer the relationship between the NVR found on the sampling plate surface and that found on any other surfaces. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. 1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

  8. Standard Test Method for Gravimetric Determination of Nonvolatile Residue From Cleanroom Wipers

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2006-01-01

    1.1 This test method covers the determination of solvent extractable nonvolatile residue (NVR) from wipers used in assembly, cleaning, or testing of spacecraft, but not from those used for analytical surface sampling of hardware. 1.2 The values stated in SI units are to be regarded as the standard. No other units of measurement are included in this standard. 1.3 The NVR of interest is that which can be extracted from cleanroom wipers using a specified solvent that has been selected for its extractive qualities. Alternative solvents may be selected, but since their use may result in different values being generated, they must be identified in the procedure data sheet. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  9. Standard test method for plastic strain ratio r for sheet metal

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2000-01-01

    1.1 This test method covers special tension testing for the measurement of the plastic strain ratio, r, of sheet metal intended for deep-drawing applications. 1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  10. Standard Test Method for Bond Strength of Ceramic Tile to Portland Cement Paste

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2002-01-01

    1.1 This test method covers the determination of the ability of glazed ceramic wall tile, ceramic mosaic tile, quarry tile, and pavers to be bonded to portland cement paste. This test method includes both face-mounted and back-mounted tile. 1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  11. Standard Test Method for Measuring Heat-Transfer Rate Using a Thermal Capacitance (Slug) Calorimeter

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 This test method describes the measurement of heat transfer rate using a thermal capacitance-type calorimeter which assumes one-dimensional heat conduction into a cylindrical piece of material (slug) with known physical properties. 1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. 1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. Note 1—For information see Test Methods E 285, E 422, E 458, E 459, and E 511.

  12. Happy eating: the single target implicit association test predicts overeating after positive emotions.

    Science.gov (United States)

    Bongers, Peggy; Jansen, Anita; Houben, Katrijn; Roefs, Anne

    2013-08-01

    For many years, questionnaires have been considered the standard when examining emotional eating behavior. However, recently, some controversy has arisen about these questionnaires, and their usefulness in identifying emotional eaters has been questioned. The current study aimed to investigate the Single Target Implicit Association Test (ST-IAT) as a measure of emotional eating. Two ST-IATs (assessing food-positive and food-negative associations respectively) and the Dutch Eating Behaviour Questionnaire (DEBQ) were compared in undergraduate students. A positive, negative or neutral mood was induced by means of a film clip, and milkshake consumption was measured during and after the mood induction. It was hypothesized that participants with strong emotion-food associations on the ST-IATs (i.e., IAT-emotional eaters) would consume more food in the emotion induction condition corresponding to that emotion, as compared to those with weak emotion-food associations as well as to those in the neutral condition. Participants who scored high on both the positive and negative ST-IATs ate more during a positive mood induction than during a negative mood induction. This effect did not extend to milkshake consumption after the mood induction procedure. In addition, IAT-positive emotional eaters consumed more food than IAT-non-emotional eaters. No effects of the DEBQ on milkshake consumption were found. It is concluded that the ST-IAT has potential as a measure of emotional eating. © 2013 Elsevier Ltd. All rights reserved.

  13. Test of "Light" cigarette counter-advertising using a standard test of advertising effectiveness

    OpenAIRE

    Shiffman, S.; Burton, S.; Pillitteri, J.; Gitchell, J.; Di, M; Sweeney, C.; Wardle, P.; Koehler, G.

    2001-01-01

    OBJECTIVE—To evaluate systematically the effectiveness of six advertising strategies (two message strategies presented in three different contexts) designed to promote smoking cessation by addressing smokers' misperceptions about Light cigarettes.
DESIGN—Smokers viewed one of six, 30 second test television concept advertisements, which varied by message (one emphasising how the sensory effects of Lights can be deceptive, the other describing the effects of vent blocking) and by ad context (no...

  14. Understanding the effect of single-fracture heterogeneity from single-well injection-withdrawal (SWIW) tests

    Science.gov (United States)

    Larsson, Martin; Doughty, Christine; Tsang, Chin-Fu; Niemi, Auli

    2013-12-01

    The single-well injection-withdrawal (SWIW) tracer test is a method used to estimate the tracer retardation properties of a fracture or fracture zone. The effects of single-fracture aperture heterogeneity on SWIW-test tracer breakthrough curves are examined by numerical modelling. The effects of the matrix diffusion and sorption are accounted for by using a particle tracking method through the addition of a time delay added to the advective transport time. For a given diffusion and sorption property ( P m) value and for a heterogeneous fracture, the peak concentration is larger compared to a homogeneous fracture. The cumulative breakthrough curve for a heterogeneous fracture is similar to that for a homogeneous fracture and a less sorptive/diffusive tracer. It is demonstrated that the fracture area that meets the flowing water, the specific flow-wetted surface (sFWS) of the fracture, can be determined by matching the observed breakthrough curve for a heterogeneous fracture to that for a homogeneous fracture with an equivalent property parameter. SWIW tests are also simulated with a regional pressure gradient present. The results point to the possibility of distinguishing the effect of the regional pressure gradient from that of diffusion through the use of multiple tracers with different P m values.

  15. Evaluation of the single-pass flow-through test to support a low-activity waste specification

    International Nuclear Information System (INIS)

    McGrail, B.P.; Peeler, D.K.

    1995-09-01

    A series of single-pass flow-through (SPFT) tests was performed on five reference low-activity waste glasses and a reference glass from the National Institute of Standards and Technology to support a product specification for low-activity waste (LAW) forms. The results showed that the SPFT test provides a means to quantitatively distinguish among LAW glass forms in terms of their forward reaction rate at a given temperature and solution pH. Two of the test glasses were also subjected to SPFT testing at Argonne National Laboratory (ANL). Forward reaction rate constants calculated from the ANL test data were 100 to over 1,000 times larger than the values obtained from the SPFT tests conducted at PNL. An analysis of the ANL results showed that they were inconsistent with independent measurements done on glasses of similar composition, the known pH-dependence of the forward rate, and with the results from low surface-area-to-volume, short duration product consistency tests. Because the data set obtained from the SPFT tests done at PNL was consistent with each of these same factors, a detailed examination of the test procedures used at both laboratories was performed to determine the cause(s) of the discrepancy. The omission of background subtraction in the data analysis procedure and the short-duration (on the order of hours) of the ANL tests are factors that may have significantly affected the calculated rates

  16. Consensus-based reporting standards for diagnostic test accuracy studies for paratuberculosis in ruminants

    DEFF Research Database (Denmark)

    Gardner, Ian A.; Nielsen, Søren Saxmose; Whittington, Richard

    2011-01-01

    The Standards for Reporting of Diagnostic Accuracy (STARD) statement (www.stard-statement.org) was developed to encourage complete and transparent reporting of key elements of test accuracy studies in human medicine. The statement was motivated by widespread evidence of bias in test accuracy...... studies and the finding that incomplete or absent reporting of items in the STARD checklist was associated with overly optimistic estimates of test performance characteristics. Although STARD principles apply broadly, specific guidelines do not exist to account for unique considerations in livestock...... studies such as herd tests, potential use of experimental challenge studies, a more diverse group of testing purposes and sampling designs, and the widespread lack of an ante-mortem reference standard with high sensitivity and specificity. The objective of the present study was to develop a modified...

  17. Standardization of shape memory alloy test methods toward certification of aerospace applications

    Science.gov (United States)

    Hartl, D. J.; Mabe, J. H.; Benafan, O.; Coda, A.; Conduit, B.; Padan, R.; Van Doren, B.

    2015-08-01

    The response of shape memory alloy (SMA) components employed as actuators has enabled a number of adaptable aero-structural solutions. However, there are currently no industry or government-accepted standardized test methods for SMA materials when used as actuators and their transition to commercialization and production has been hindered. This brief fast track communication introduces to the community a recently initiated collaborative and pre-competitive SMA specification and standardization effort that is expected to deliver the first ever regulatory agency-accepted material specification and test standards for SMA as employed as actuators for commercial and military aviation applications. In the first phase of this effort, described herein, the team is working to review past efforts and deliver a set of agreed-upon properties to be included in future material certification specifications as well as the associated experiments needed to obtain them in a consistent manner. Essential for the success of this project is the participation and input from a number of organizations and individuals, including engineers and designers working in materials and processing development, application design, SMA component fabrication, and testing at the material, component, and system level. Going forward, strong consensus among this diverse body of participants and the SMA research community at large is needed to advance standardization concepts for universal adoption by the greater aerospace community and especially regulatory bodies. It is expected that the development and release of public standards will be done in collaboration with an established standards development organization.

  18. Standard Test Method for Resin Flow of Carbon Fiber-Epoxy Prepreg

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1999-01-01

    1.1 This test method covers the determination of the amount of resin flow that will take place from prepreg tape or sheet under given conditions of temperature and pressure. 1.2 The values stated in SI units are to be regarded as standard. The values in parentheses are for reference only. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  19. Evaluation of the performance test uncertainties of a primary standard for low energy X-ray

    International Nuclear Information System (INIS)

    Cardoso, Ricardo de Souza; Peixoto, Jose Guilherme P.

    2005-01-01

    The present work was developed with the aim to check the reliability of the free-air ionization chamber with variable volume, manufactured by Victoreen Instruments, model 481 as a primary standard, used by Laboratorio Nacional de Metrologia das Radiacoes Ionizantes - LNMRI of IRD in order to measure the quantity ar kerma. To that were evaluates the uncertainties in each test done with the equipment during the process of its characterization as a standard. The results has a behaviour characteristics of a primary standard, being simple to handle, mechanical construction and showing an expanded uncertainty equal to 0,26%, which, corresponds to a 30 kV quality. (author)

  20. Standard test method for measurement of soil resistivity using the two-electrode soil box method

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2005-01-01

    1.1 This test method covers the equipment and a procedure for the measurement of soil resistivity, for samples removed from the ground, for use in the control of corrosion of buried structures. 1.2 Procedures allow for this test method to be used n the field or in the laboratory. 1.3 The test method procedures are for the resistivity measurement of soil samples in the saturated condition and in the as-received condition. 1.4 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only. Soil resistivity values are reported in ohm-centimeter. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and to determine the applicability of regulatory limitations prior to use.

  1. A comparison between standard well test evaluation methods used in SKB's site investigations and the generalised radial flow concept

    International Nuclear Information System (INIS)

    Follin, Sven; Ludvigson, Jan-Erik; Leven, Jakob

    2011-09-01

    According to the strategy for hydrogeological characterisation within the SKB's site investigation programme, two single-hole test methods are available for testing and parameterisation of groundwater flow models - constant-head injection testing with the Pipe String System (PSS method) and difference flow logging with the Posiva Flow Log (PFL method). This report presents the results of an investigation to assess discrepancies in the results of single-hole transmissivity measurements using these methods in the Forsmark site characterisation. The investigation explores the possibility that the source of the discrepancy observed lies in the assumptions of the flow geometry that are inherent to the methods used for standard constant-head injection well test analysis and difference flow logging analysis, respectively. In particular, the report looks at the generalised radial flow (GRF) concept by Barker (1988) as a means that might explain some of the differences. A confirmation of the actual flow geometries (dimensions) observed during hydraulic injection tests could help to identify admissible conceptual models for the tested system, and place the hydraulic testing with the PSS and PFL test methods in its full hydrogeological context. The investigation analyses 151 constant-head injection tests in three cored boreholes at Forsmark. The results suggest that the transmissivities derived with standard constant-head injection well test analysis methods and with the GRF concept, respectively, are similar provided that the dominating flow geometry during the testing is radial (cylindrical). Thus, having flow geometries with dimensions other than 2 affects the value of the interpreted transmissivity. For example, a flow system with a dimension of 1 may require an order of magnitude or more, higher transmissivity to produce the same flow rates. The median of the GRF flow dimensions of all 151 constant-head injection tests is 2.06 with 33% of the tests in the range 1

  2. The Influence of Age on Interaction between Breath-Holding Test and Single-Breath Carbon Dioxide Test

    Directory of Open Access Journals (Sweden)

    Nikita Trembach

    2017-01-01

    Full Text Available Introduction. The aim of the study was to compare the breath-holding test and single-breath carbon dioxide test in evaluation of the peripheral chemoreflex sensitivity to carbon dioxide in healthy subjects of different age. Methods. The study involved 47 healthy volunteers between ages of 25 and 85 years. All participants were divided into 4 groups according to age: 25 to 44 years (n=14, 45 to 60 years (n=13, 60 to 75 years (n=12, and older than 75 years (n=8. Breath-holding test was performed in the morning before breakfast. The single-breath carbon dioxide (SB-CO2 test was performed the following day. Results. No correlation was found between age and duration of breath-holding (r=0.13 and between age and peripheral chemoreflex sensitivity to CO2 (r=0.07. In all age groups there were no significant differences in the mean values from the breath-holding test and peripheral chemoreflex sensitivity tests. In all groups there was a strong significant inverse correlation between breath-holding test and SB-CO2 test. Conclusion. A breath-holding test reflects the sensitivity of the peripheral chemoreflex to carbon dioxide in healthy elderly humans. Increasing age alone does not alter the peripheral ventilatory response to hypercapnia.

  3. The Influence of Age on Interaction between Breath-Holding Test and Single-Breath Carbon Dioxide Test.

    Science.gov (United States)

    Trembach, Nikita; Zabolotskikh, Igor

    2017-01-01

    Introduction . The aim of the study was to compare the breath-holding test and single-breath carbon dioxide test in evaluation of the peripheral chemoreflex sensitivity to carbon dioxide in healthy subjects of different age. Methods . The study involved 47 healthy volunteers between ages of 25 and 85 years. All participants were divided into 4 groups according to age: 25 to 44 years ( n = 14), 45 to 60 years ( n = 13), 60 to 75 years ( n = 12), and older than 75 years ( n = 8). Breath-holding test was performed in the morning before breakfast. The single-breath carbon dioxide (SB-CO 2 ) test was performed the following day. Results . No correlation was found between age and duration of breath-holding ( r = 0.13) and between age and peripheral chemoreflex sensitivity to CO 2 ( r = 0.07). In all age groups there were no significant differences in the mean values from the breath-holding test and peripheral chemoreflex sensitivity tests. In all groups there was a strong significant inverse correlation between breath-holding test and SB-CO 2 test. Conclusion . A breath-holding test reflects the sensitivity of the peripheral chemoreflex to carbon dioxide in healthy elderly humans. Increasing age alone does not alter the peripheral ventilatory response to hypercapnia.

  4. Test of "Light" cigarette counter-advertising using a standard test of advertising effectiveness.

    Science.gov (United States)

    Shiffman, S; Burton, S L; Pillitteri, J L; Gitchell, J G; Di Marino, M E; Sweeney, C T; Wardle, P A; Koehler, G L

    2001-01-01

    To evaluate systematically the effectiveness of six advertising strategies (two message strategies presented in three different contexts) designed to promote smoking cessation by addressing smokers' misperceptions about Light cigarettes. Smokers viewed one of six, 30 second test television concept advertisements, which varied by message (one emphasising how the sensory effects of Lights can be deceptive, the other describing the effects of vent blocking) and by ad context (non-commercial public service announcement (PSA), promotion of unbranded nicotine replacement therapy (NRT), or promotion of branded NRT). The effectiveness of each advertisement was determined using a validated advertising testing system in which ads were viewed in the context of reviewing a pilot television programme. Response to ads is assessed through shifts in subject choices of products offered as prizes before and after viewing the test advertisements. Included among the possible prizes were cigarettes and various pharmacotherapies for smoking cessation. Daily smokers (n = 1890) of Regular (34%), Light (47%), and Ultra Light (19%) cigarettes recruited from eight US cities. The primary outcome of interest was the shift away from cigarettes as the selected prize following exposure to the test advertisements. Secondary outcomes of interest included movement away from Light cigarettes and movement towards assisted quitting products. Smokers who saw the advertisement emphasising the sensory characteristics of Light cigarettes were more likely than subjects who saw the advertisement emphasising the effect of vent blocking to move away from cigarettes (OR = 1.97, 95% confidence interval CI 1.25 to 3.09; chi(2)(1) = 8.69, p = 0.003). Similarly, subjects who saw the advertisement framed as a PSA, rather than as a promotion for either a branded or unbranded NRT product, were also somewhat more likely to move away from cigarettes (OR = 1.51, 95% CI 0.94 to 2.40; chi(2)(1) = 2.97, p = 0.085). The

  5. Termite-Susceptible Species of Wood for Inclusion as a Reference in Indonesian Standardized Laboratory Testing

    Directory of Open Access Journals (Sweden)

    Arinana

    2012-03-01

    Full Text Available Standardized laboratory testing of wood and wood-based products against subterranean termites in Indonesia (SNI 01.7207-2006 (SNI has no requirement for the inclusion of a comparative reference species of wood (reference control. This is considered a weakness of the Indonesian standard. Consequently, a study was undertaken to identify a suitable Indonesian species of community wood that could be used as a reference control. Four candidate species of community woods: Acacia mangium, Hevea brasiliensis, Paraserianthes falcataria and Pinus merkusii were selected for testing their susceptibility to feeding by Coptotermes formosanus. Two testing methods (SNI and the Japanese standard method JIS K 1571-2004 were used to compare the susceptibility of each species of wood. Included in the study was Cryptomeria japonica, the reference control specified in the Japanese standard. The results of the study indicated that P. merkusii is a suitable reference species of wood for inclusion in laboratory tests against subterranean termites, conducted in accordance with the Indonesian standard (SNI 01.7207-2006.

  6. Analytical solutions for efficient interpretation of single-well push-pull tracer tests

    Science.gov (United States)

    Single-well push-pull tracer tests have been used to characterize the extent, fate, and transport of subsurface contamination. Analytical solutions provide one alternative for interpreting test results. In this work, an exact analytical solution to two-dimensional equations descr...

  7. Fibre reinforced concrete in flexure and single fibre pull-out test: a correlation

    Science.gov (United States)

    Manca, M.; Ciancio, D.; Dight, P.

    2017-09-01

    The aim of the present work is to assess whether a single fibre pull-out test can be related to the behaviour of multiple fibres in fibre reinforced concrete under bending condition. A simple model based on the stress block theory is described and compared with experimental results on three point bending tests with aligned fibres.

  8. Content Coverage of Single-Word Tests Used to Assess Common Phonological Error Patterns

    Science.gov (United States)

    Kirk, Cecilia; Vigeland, Laura

    2015-01-01

    Purpose: This review evaluated whether 9 single-word tests of phonological error patterns provide adequate content coverage to accurately identify error patterns that are active in a child's speech. Method: Tests in the current study were considered to display sufficient opportunities to assess common phonological error patterns if they…

  9. The development and standardization of testing methods for genetically modified organisms and their derived products.

    Science.gov (United States)

    Zhang, Dabing; Guo, Jinchao

    2011-07-01

    As the worldwide commercialization of genetically modified organisms (GMOs) increases and consumers concern the safety of GMOs, many countries and regions are issuing labeling regulations on GMOs and their products. Analytical methods and their standardization for GM ingredients in foods and feed are essential for the implementation of labeling regulations. To date, the GMO testing methods are mainly based on the inserted DNA sequences and newly produced proteins in GMOs. This paper presents an overview of GMO testing methods as well as their standardization. © 2011 Institute of Botany, Chinese Academy of Sciences.

  10. Mechanical properties test and microstructure analysis of polyoxymethylene (POM) micro injection moulded standard parts

    DEFF Research Database (Denmark)

    Tosello, Guido; Lucchetta, Giovanni; Hansen, Hans Nørgaard

    2009-01-01

    The tensile mechanical properties and the micro structure of micro injection moulded polyoxymethylene (POM) test parts were investigated in this paper. The effects of different injection moulding processing conditions on ultimate tensile stress and strain at break were analyzed. Additionally......, the effects of miniaturization on the mechanical properties were investigated by executing injection moulding with both a standard tool designed according to ISO 527-2 and a miniaturized test part obtained from the standard design by a downscaling factor 10. The experiments have been performed according...

  11. Standard test method for plutonium assay by plutonium (III) diode array spectrophotometry

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2002-01-01

    1.1 This test method describes the determination of total plutonium as plutonium(III) in nitrate and chloride solutions. The technique is applicable to solutions of plutonium dioxide powders and pellets (Test Methods C 697), nuclear grade mixed oxides (Test Methods C 698), plutonium metal (Test Methods C 758), and plutonium nitrate solutions (Test Methods C 759). Solid samples are dissolved using the appropriate dissolution techniques described in Practice C 1168. The use of this technique for other plutonium-bearing materials has been reported (1-5), but final determination of applicability must be made by the user. The applicable concentration range for plutonium sample solutions is 10–200 g Pu/L. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropria...

  12. Standard and generalized McDonald–Kreitman test: a website to detect selection by comparing different classes of DNA sites

    Science.gov (United States)

    Egea, Raquel; Casillas, Sònia; Barbadilla, Antonio

    2008-01-01

    The McDonald and Kreitman test (MKT) is one of the most powerful and extensively used tests to detect the signature of natural selection at the molecular level. Here, we present the standard and generalized MKT website, a novel website that allows performing MKTs not only for synonymous and nonsynonymous changes, as the test was initially described, but also for other classes of regions and/or several loci. The website has three different interfaces: (i) the standard MKT, where users can analyze several types of sites in a coding region, (ii) the advanced MKT, where users can compare two closely linked regions in the genome that can be either coding or noncoding, and (iii) the multi-locus MKT, where users can analyze many separate loci in a single multi-locus test. The website has already been used to show that selection efficiency is positively correlated with effective population size in the Drosophila genus and it has been applied to include estimates of selection in DPDB. This website is a timely resource, which will presumably be widely used by researchers in the field and will contribute to enlarge the catalogue of cases of adaptive evolution. It is available at http://mkt.uab.es. PMID:18515345

  13. Standard and generalized McDonald-Kreitman test: a website to detect selection by comparing different classes of DNA sites.

    Science.gov (United States)

    Egea, Raquel; Casillas, Sònia; Barbadilla, Antonio

    2008-07-01

    The McDonald and Kreitman test (MKT) is one of the most powerful and extensively used tests to detect the signature of natural selection at the molecular level. Here, we present the standard and generalized MKT website, a novel website that allows performing MKTs not only for synonymous and nonsynonymous changes, as the test was initially described, but also for other classes of regions and/or several loci. The website has three different interfaces: (i) the standard MKT, where users can analyze several types of sites in a coding region, (ii) the advanced MKT, where users can compare two closely linked regions in the genome that can be either coding or noncoding, and (iii) the multi-locus MKT, where users can analyze many separate loci in a single multi-locus test. The website has already been used to show that selection efficiency is positively correlated with effective population size in the Drosophila genus and it has been applied to include estimates of selection in DPDB. This website is a timely resource, which will presumably be widely used by researchers in the field and will contribute to enlarge the catalogue of cases of adaptive evolution. It is available at http://mkt.uab.es.

  14. Usage of Latent Class Analysis in Diagnostic Microbiology in the Absence of Gold Standard Test

    Directory of Open Access Journals (Sweden)

    Gul Bayram Abiha

    2016-12-01

    Full Text Available The evaluation of performance of various tests diagnostic tests in the absence of gold standard is an important problem. Latent class analysis (LCA is a statistical analysis method known for many years, especially in the absence of a gold standard for evaluation of diagnostic tests so that LCA has found its wide application area. During the last decade, LCA method has widely used in for determining sensivity and specifity of different microbiological tests. It has investigated in the diagnosis of mycobacterium tuberculosis, mycobacterium bovis, human papilloma virus, bordetella pertussis, influenza viruses, hepatitis E virus (HEV, hepatitis C virus (HCV and other various viral infections. Researchers have compared several diagnostic tests for the diagnosis of different pathogens with LCA. We aimed to evaluate performance of latent class analysis method used microbiological diagnosis in various diseases in several researches. When we took into account all of these tests' results, we suppose that LCA is a good statistical analysis method to assess different test performances in the absence of gold standard. [Archives Medical Review Journal 2016; 25(4.000: 467-488

  15. External and internal standards in the single-isotope derivative (radioenzymatic) measurement of plasma norepinephrine and epinephrine

    International Nuclear Information System (INIS)

    Shah, S.D.; Clutter, W.E.; Cryer, P.E.

    1985-01-01

    In plasma from normal humans (n = 9, 35 samples) and from patients with diabetes mellitus (n = 12, 24 samples) single-isotope derivative (radioenzymatic) plasma norepinephrine and epinephrine concentrations calculated from external standard curves constructed in a normal plasma pool were identical to those calculated from internal standards added to an aliquot of each plasma sample. In plasma from patients with end-stage renal failure receiving long-term dialysis (n = 34, 109 samples), competitive catechol-O-methyltransferase (COMT) inhibitory activity resulted in a systematic error when external standards in a normal plasma pool were used, as reported previously; values so calculated averaged 21% (+/- 12%, SD) lower than those calculated from internal standards. However, when external standard curves were constructed in plasma from a given patient with renal failure and used to calculate that patient's values, or in a renal failure plasma pool and used to calculate all renal failure values, norepinephrine and epinephrine concentrations were not significantly different from those calculated from internal standards. We conclude: (1) External standard curves constructed in plasma from a given patient with renal failure can be used to measure norepinephrine and epinephrine in plasma from that patient; further, external standards in a renal failure plasma pool can be used for assays in patients with end-stage renal failure receiving long-term dialysis. (2) Major COMT inhibitory activity is not present commonly if samples from patients with renal failure are excluded. Thus, it would appear that external standard curves constructed in normal plasma can be used to measure norepinephrine and epinephrine precisely in samples from persons who do not have renal failure

  16. Nuclear reactor pressure vessel surveillance capsule examinations. Application of American Society for Testing and Materials Standards

    International Nuclear Information System (INIS)

    Perrin, J.S.

    1978-01-01

    A series of pressure vessel surveillance capsules is installed in each commercial nuclear power plant in the United States. A capsule typically contains neutron dose meters, thermal monitors, tensile specimens, and Charpy V-notch impact specimens. In order to determine property changes of the pressure vessel resulting from irradiation, surveillance capsules are periodically removed during the life of a reactor and examined. There are numerous standards, regulations, and codes governing US pressure vessel surveillance capsule programmes. These are put out by the US Nuclear Regulatory Commission, the Boiler and Pressure Vessel Committee of the American Society of Mechanical Engineers, and the American Society for Testing and Materials (ASTM). A majority of the pertinent ASTM standards are under the jurisdiction of ASTM Committee E-10 on Nuclear Applications and Measurements of Radiation Effects. The standards, regulations, and codes pertaining to pressure vessel surveillance play an important role in ensuring reliability of the nuclear pressure vessels. ASTM E 185-73 is the Standard Recommended Practice for Surveillance Tests for Nuclear Reactors. This standard recommends procedures for both the irradiation and subsequent testing of surveillance capsules. ASTM E 185-73 references many additional specialized ASTM standards to be followed in specific areas of a surveillance capsule examination. A key element of surveillance capsule programmes is the Charpy V-notch impact test, used to define curves of fracture behaviour over a range of temperatures. The data from these tests are used to define the adjusted reference temperature used in determining pressure-temperature operating curves for a nuclear power plant. (author)

  17. Still no single gold standard for using cementless femoral stems routinely in total hip arthroplasty

    Directory of Open Access Journals (Sweden)

    Joseph T. Moskal, MD

    2016-12-01

    Conclusions: Using evidence-based data should be better guidance in selecting the most reliable implants for THA. Although cementless femoral fixation for THA has evolved to the “new standard,” it has not been proven to be the “gold standard” for all patients.

  18. Standard test method for calibration of surface/stress measuring devices

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1997-01-01

    Return to Contents page 1.1 This test method covers calibration or verification of calibration, or both, of surface-stress measuring devices used to measure stress in annealed and heat-strengthened or tempered glass using polariscopic or refractometry based principles. 1.2 This test method is nondestructive. 1.3 This test method uses transmitted light, and therefore, is applicable to light-transmitting glasses. 1.4 This test method is not applicable to chemically tempered glass. 1.5 Using the procedure described, surface stresses can be measured only on the “tin” side of float glass. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  19. Reliability Assessment of a Single-Shot System by Use of Screen Test Results

    Science.gov (United States)

    2018-02-01

    unlimited. NUWC Keyport #17-002. Reliability Assessment of a Single-Shot System by Use of Screen Test Results Abstract: Field reliability prediction...approach described here assumes that the defect density during testing takes the form of an exponential decay, although other mathematical functions can...be substituted for the exponential. In order to apply the decay rate function to a discrete pass/fail test scheme, the approach provides for

  20. The Influence of Age on Interaction between Breath-Holding Test and Single-Breath Carbon Dioxide Test

    OpenAIRE

    Trembach, Nikita; Zabolotskikh, Igor

    2017-01-01

    Introduction. The aim of the study was to compare the breath-holding test and single-breath carbon dioxide test in evaluation of the peripheral chemoreflex sensitivity to carbon dioxide in healthy subjects of different age. Methods. The study involved 47 healthy volunteers between ages of 25 and 85 years. All participants were divided into 4 groups according to age: 25 to 44 years (n = 14), 45 to 60 years (n = 13), 60 to 75 years (n = 12), and older than 75 years (n = 8). Breath-holding test ...

  1. Standard review plan for the review and evaluation of emergency plans for research and test reactors

    International Nuclear Information System (INIS)

    1983-10-01

    This document provides a Standard Review Plan to assure that complete and uniform reviews are made of research and test reactor radiological emergency plans. The report is organized under ten planning standards which correspond to the guidance criteria in American National Standard ANSI/ANS 15.16 - 1982 as endorsed by Revision 1 to Regulatory Guide 2.6. The applicability of the items under each planning standard is indicated by subdivisions of the steady-state thermal power levels at which the reactors are licensed to operate. Standard emergency classes and example action levels for research and test reactors which should initiate these classes are given in an Appendix. The content of the emergency plan is as follows: the emergency plan addresses the necessary provisions for coping with radiological emergencies. Activation of the emergency plan is in response to the emergency action levels. In addition to addressing those severe emergencies that will fall within one of the standard emergency classes, the plan also discusses the necessary provisions to deal with radiological emergencies of lesser severity that can occur within the operations boundary. The emergency plan allows for emergency personnel to deviate from actions described in the plan for unusual or unanticipated conditions

  2. Standard test method for determining nodularity and nodule count in ductile iron using image analysis

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2011-01-01

    1.1 This test method is used to determine the percent nodularity and the nodule count per unit area (that is, number of nodules per mm2) using a light microscopical image of graphite in nodular cast iron. Images generated by other devices, such as a scanning electron microscope, are not specifically addressed, but can be utilized if the system is calibrated in both x and y directions. 1.2 Measurement of secondary or temper carbon in other types of cast iron, for example, malleable cast iron or in graphitic tool steels, is not specifically included in this standard because of the different graphite shapes and sizes inherent to such grades 1.3 This standard deals only with the recommended test method and nothing in it should be construed as defining or establishing limits of acceptability or fitness for purpose of the material tested. 1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.5 This standard does not purport to address al...

  3. SEU testing of a novel hardened register implemented using standard CMOS technology

    International Nuclear Information System (INIS)

    Monnier, T.; Roche, F.M.; Cosculluela, J.; Velazco, R.

    1999-01-01

    A novel memory structure, designed to tolerate SEU perturbations, has been implemented in registers and tested. The design was completed using a standard submicron nonradiation hardened CMOS technology. This paper presents the results of heavy ions tests which evidence the noticeable improvement of the SEU-robustness with an increased LET threshold and reduced cross-section, without significant impact to die real estate, write time, or power consumption

  4. A comparative study of standard versus laparoendoscopic single-site surgery (LESS) totally extraperitoneal (TEP) inguinal hernia repair.

    Science.gov (United States)

    Tai, Huai-Ching; Lin, Chia-Da; Chung, Shiu-Dong; Chueh, Shih-Chieh Jeff; Tsai, Yao-Chou; Yang, Stephen Shei-Dei

    2011-09-01

    Laparoscopic inguinal hernia repair has been around since the 1990s. A novel surgical approach known as laparoendoscopic single-site surgery (LESS) has been developed to reduce the port-related morbidities and improve the cosmetic outcomes of laparoscopic surgery, including totally extraperitoneal (TEP) inguinal hernia repair. The aim of the present study was to evaluate the safety and feasibility of the LESS TEP technique for inguinal hernia repair and compare the outcomes with the standard TEP approach. Between January and May 2009, 54 consecutive healthy patients (48 men and 6 women) underwent LESS TEP inguinal hernia repair at our institute. All procedures were performed using our homemade single port for simultaneous passage of the laparoscope and instruments. The perioperative data, including patient age, sex, body mass index (BMI), hernia characteristics, operative time, complications, length of hospital stay, return to normal activity, pain score, and cosmetic result, were prospectively collected. All LESS TEP procedures were completed successfully without conversion to standard laparoscopic or open surgery. A total of 98 LESS TEP hernia repairs were performed in 54 patients and compared with 152 standard TEP operations. The mean operative time was significantly shorter in the standard TEP series (61.8 ± 26.0 vs. 70.9 ± 23.8 min, p = 0.04). Other perioperative parameters, including the length of hospital stay, time until return to full activity, complication rate, pain score, and cosmetic result, were all comparable between the two techniques. Our short-term experience with LESS TEP inguinal hernia repair has shown that in experienced hands, inguinal hernia repair via the LESS TEP technique is as safe as the standard TEP technique. However, based on our evidence, we currently believe that the LESS TEP technique is not an efficacious surgical alternative to the standard TEP technique for inguinal hernias.

  5. Development and Standardization of a Test for Pragmatic Language Skills in Egyptian Arabic: The Egyptian Arabic Pragmatic Language Test (EAPLT).

    Science.gov (United States)

    Khodeir, Mona S; Hegazi, Mona A; Saleh, Marwa M

    2018-03-19

    The aim of this study was to standardize an Egyptian Arabic Pragmatic Language Test (EAPLT) using linguistically and socially suitable questions and pictures in order to be able to address specific deficits in this language domain. Questions and pictures were designed for the EAPLT to assess 3 pragmatic language subsets: pragmatic skills, functions, and factors. Ten expert phoniatricians were asked to review the EAPLT and complete a questionnaire to assess the validity of the test items. The EAPLT was applied in 120 typically developing Arabic-speaking Egyptian children (64 females and 56 males) randomly selected by inclusion and exclusion criteria in the age range between 2 years, 1 month, 1 day and 9 years, 12 months, 31 days. Children's scores were used to calculate the means and standard deviations and the 5th and 95th percentiles to determine the age of the pragmatic skills acquisition. All experts have mostly agreed that the EAPLT gives a general idea about children's pragmatic language development. Test-retest reliability analysis proved the high reliability and internal consistency of the EAPLT subsets. A statistically significant correlation was found between the test subsets and age. The EAPLT is a valid and reliable Egyptian Arabic test that can be applied in order to detect a pragmatic language delay. © 2018 S. Karger AG, Basel.

  6. Cytotoxicity Test of One-Step Self-Etching Bonding Agents by Standardized Dentin Barrier Test Using Polyurethane Discs

    Directory of Open Access Journals (Sweden)

    Mi-Joo Kim

    2013-12-01

    Full Text Available This study was performed to standardize a dentin barrier test with the substitute and evaluate the cytotoxicity of one-step self-etching bonding agents. Each of the natural bovine dentin and polyurethane discs were 500-μm thick and were tested using a perfusion device. Following the treatment with 0.05% phenol on the natural bovine disc or three kinds of polyurethane discs—30, 40, and 50 pcf (pounds per cubic foot—cell viability of L-929 was measured by the 3-(4,5-dimethylthiazol-2-yl-2,5-diphenyltetrazolium bromide (MTT assay and expressed as percentages of non-treated group, respectively. A substitute showing permeability similar to that of bovine dentin was determined based on this result. Cytotoxicity test of bonding agents was performed by the selected substitute, the results of which were expressed as percentages of the control. In addition, SEM images were taken after the tests. The cell viability by 40-pcf polyurethane disc was not statistically different from that by bovine dentin disc (P > 0.05. Futurabond DC resulted in the highest cell viability and Bond force the lowest by the 40-pcf polyurethane disc (P < 0.05. The adhesives on the 40-pcf polyurethane disc changed cellular morphology with different degrees on the SEM images. This standardized test might be useful for assessing the cytotoxicity of dental materials applied to dentin before clinical applications.

  7. Homogeneity tests for variances and mean test under heterogeneity conditions in a single way ANOVA method

    International Nuclear Information System (INIS)

    Morales P, J.R.; Avila P, P.

    1996-01-01

    If we have consider the maximum permissible levels showed for the case of oysters, it results forbidding to collect oysters at the four stations of the El Chijol Channel ( Veracruz, Mexico), as well as along the channel itself, because the metal concentrations studied exceed these limits. In this case the application of Welch tests were not necessary. For the water hyacinth the means of the treatments were unequal in Fe, Cu, Ni, and Zn. This case is more illustrative, for the conclusion has been reached through the application of the Welch tests to treatments with heterogeneous variances. (Author)

  8. Standardization, Validity and Reliability Study of Gülhane Aphasia Test-2 (GAT-2

    Directory of Open Access Journals (Sweden)

    İlknur Maviş

    2007-04-01

    Full Text Available OBJECTIVE: Gülhane Aphasia Test-2 (GAT-2 has been developed to show the presence of a language disorder ‘aphasia’ and to give the clinician implications for the accompanying speech disorders such as apraxia and dysarthria. OBJECTIVE: The aim of the study was to report standardization, validity and reliability study of GAT-2. METHODS: : 10 healthy individuals were tested initially for the pilot study. 134 healthy individual was included to the standardization study and 30 individuals with aphasia and 11 individuals with right brain injury was included to the validation study. The inter group GAT-2 score differentiations and the effects of age, years of education, sex variances were observed. GAT-2 cut-off scores were calculated by the scores of healthy individuals. GAT-2 test-retest reliability and inter-observer reliability was calculated. RESULTS: Healthy individuals’ GAT-2 scores were significantly different from the GAT-2 scores of aphasic patients, but not from right brain injured patients’. Healthy individuals’ GAT-2 scores were not affected from the sex, age variances but from years of education, so cut-off scores were calculated by this variance. GAT-2 scores of aphasic patients were not affected from age, sex and years of education. Test-retest and inter-observer reliability and internal consistency results showed that GAT-2 is a highly reliable aphasia screening test. CONCLUSION: GAT-2 was found to be a standardized, highly reliable and a valid aphasia test for Turkish stroke patients with aphasia

  9. Standard test method for ranking resistance of materials to sliding wear using block-on-ring wear test

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2005-01-01

    1.1 This test method covers laboratory procedures for determining the resistance of materials to sliding wear. The test utilizes a block-on-ring friction and wear testing machine to rank pairs of materials according to their sliding wear characteristics under various conditions. 1.2 An important attribute of this test is that it is very flexible. Any material that can be fabricated into, or applied to, blocks and rings can be tested. Thus, the potential materials combinations are endless. However, the interlaboratory testing has been limited to metals. In addition, the test can be run with various lubricants, liquids, or gaseous atmospheres, as desired, to simulate service conditions. Rotational speed and load can also be varied to better correspond to service requirements. 1.3 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only. Wear test results are reported as the volume loss in cubic millimetres for both the block and ring. Materials...

  10. Standard Test Method for Water Absorption of Core Materials for Structural Sandwich Constructions

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2001-01-01

    1.1 This test method covers the determination of the relative amount of water absorption by various types of structural core materials when immersed or in a high relative humidity environment. This test method is intended to apply to only structural core materials; honeycomb, foam, and balsa wood. 1.2 The values stated in SI units are to be regarded as the standard. The inch-pound units given may be approximate. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  11. Standard guide for conducting wear tests using a rotary platform, double-head abraser

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 This guide covers and is intended to assist in establishing procedures for conducting wear tests of rigid or flexible materials utilizing the rotary platform, double-head abraser (RPDH). 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.2.1 Exception—English units are used when determining coating thickness. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  12. Standard test method for measurement of corrosion potentials of Aluminum alloys

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1997-01-01

    1.1 This test method covers a procedure for measurement of the corrosion potential (see Note 1) of an aluminum alloy in an aqueous solution of sodium chloride with enough hydrogen peroxide added to provide an ample supply of cathodic reactant. Note 1—The corrosion potential is sometimes referred to as the open-circuit solution or rest potential. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  13. Overall migration test in food packaging: Evaluation of alternative internal standards

    Directory of Open Access Journals (Sweden)

    Edgar Andres Avendaño Florez

    2018-01-01

    Full Text Available In the global migration test for plastic packaging intended for fatty foods, glyceryl triheptadecanoate (GTM is used as the internal standard for the quantification of fatty acid methyl esters (FAMEs by gas chromatography. In this work, ethyl 3-phenyl propanoate (EFP and tetradecanoic acid (AM were evaluated as alternative internal standards. The use of (AM presented linear behavior (r > 0.99 and %Sb < 5%, good intermediate precision (HORRATr = 0.9, and accuracy (%R = 100.6%. In contrast, the evaluation of (EFP demonstrated that this is not an adequate internal standard for the quantification of FAMEs. In addition, it was statistically evaluated that there are no significant differences in the calculation of the global migration from FAMEs quantified using GTM or AM as internal standards, but the use of EFP presents significant differences.

  14. Standard Test Method for Hail Impact Resistance of Aerospace Transparent Enclosures

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This test method covers the determination of the impact resistance of an aerospace transparent enclosure, hereinafter called windshield, during hailstorm conditions using simulated hailstones consisting of ice balls molded under tightly controlled conditions. 1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements see Section 7.

  15. Standard test method for plutonium by Iron (II)/Chromium (VI) amperometric titration

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2002-01-01

    1.1 This test method covers the determination of plutonium in unirradiated nuclear-grade plutonium dioxide, uranium-plutonium mixed oxides with uranium (U)/plutonium (Pu) ratios up to 21, plutonium metal, and plutonium nitrate solutions. Optimum quantities of plutonium to measure are 7 to 15 mg. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  16. Reaction of single-standard DNA with hydroxyl radical generated by iron(II)-ethylenediaminetetraacetic acid

    International Nuclear Information System (INIS)

    Prigodich, R.V.; Martin, C.T.

    1990-01-01

    This study demonstrates that the reaction of Fe(II)-EDTA and hydrogen peroxide with the single-stranded nucleic acids d(pT) 70 and a 29-base sequence containing a mixture of bases results in substantial damage which is not directly detected by gel electrophoresis. Cleavage of the DNA sugar backbone is enhanced significantly after the samples are incubated at 90 degree C in the presence of piperidine. The latter reaction is used in traditional Maxam-Gilbert DNA sequencing to detect base damage, and the current results are consistent with reaction of the hydroxyl radical with the bases in single-stranded DNA (although reaction with sugar may also produce adducts that are uncleaved but labile to cleavage by piperidine). We the authors propose that hydroxyl radicals may react preferentially with the nucleic acid bases in ssDNA and that reaction of the sugars in dsDNA is dominant because the bases are sequestered within the double helix. These results have implications both for the study of single-stranded DNA binding protein binding sites and for the interpretation of experiments using the hydroxyl radical to probe DNA structure or to footprint double-stranded DNA binding protein binding sites

  17. The effect of instructional methodology on high school students natural sciences standardized tests scores

    Science.gov (United States)

    Powell, P. E.

    Educators have recently come to consider inquiry based instruction as a more effective method of instruction than didactic instruction. Experience based learning theory suggests that student performance is linked to teaching method. However, research is limited on inquiry teaching and its effectiveness on preparing students to perform well on standardized tests. The purpose of the study to investigate whether one of these two teaching methodologies was more effective in increasing student performance on standardized science tests. The quasi experimental quantitative study was comprised of two stages. Stage 1 used a survey to identify teaching methods of a convenience sample of 57 teacher participants and determined level of inquiry used in instruction to place participants into instructional groups (the independent variable). Stage 2 used analysis of covariance (ANCOVA) to compare posttest scores on a standardized exam by teaching method. Additional analyses were conducted to examine the differences in science achievement by ethnicity, gender, and socioeconomic status by teaching methodology. Results demonstrated a statistically significant gain in test scores when taught using inquiry based instruction. Subpopulation analyses indicated all groups showed improved mean standardized test scores except African American students. The findings benefit teachers and students by presenting data supporting a method of content delivery that increases teacher efficacy and produces students with a greater cognition of science content that meets the school's mission and goals.

  18. Interpretive Issues with the Roberts Apperception Test for Children: Limitations of the Standardization Group.

    Science.gov (United States)

    Bell, Nancy L.; Nagle, Richard J.

    1999-01-01

    Investigates the validity of the Roberts Apperception Test for Children (RATC) by examining the appropriateness of the standardization norms with other nonclinical samples. Findings suggest that the children in this study form a separate and distinct group from the well-adjusted children upon which the RATC scales were normed and supports previous…

  19. The Quest for Standard Tests in Prioritizing Water Use Rights in ...

    African Journals Online (AJOL)

    Moreover, there are problems of depletion, pollution, water grabbing, wastage of water, and water crisis that are attributable to lack of comprehensive regulations, or confusions in putting policy options. The regulatory tools lack clarity and sufficiency with regard to the incorporation of standard tests. There is thus the need for ...

  20. Standard guide for conducting and evaluating galvanic corrosion tests in electrolytes

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1981-01-01

    1.1 This guide covers conducting and evaluating galvanic corrosion tests to characterize the behavior of two dissimilar metals in electrical contact in an electrolyte under low-flow conditions. It can be adapted to wrought or cast metals and alloys. 1.2 This guide covers the selection of materials, specimen preparation, test environment, method of exposure, and method for evaluating the results to characterize the behavior of galvanic couples in an electrolyte. Note 1—Additional information on galvanic corrosion testing and examples of the conduct and evaluation of galvanic corrosion tests in electrolytes are given in Refs (1) through (7). 1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicabil...

  1. The Introduction of Standardized External Testing in Ukraine: Challenges and Successes

    Science.gov (United States)

    Kovalchuk, Serhiy; Koroliuk, Svitlana

    2012-01-01

    Standardized external testing (SET) began to be implemented in Ukraine in 2008 as an instrument for combating corruption in higher education and ensuring fair university admission. This article examines the conditions and processes that led to the introduction of SET, overviews its implementation over three years (2008-10), analyzes SET and…

  2. Chaos and Complexities Theories. Superposition and Standardized Testing: Are We Coming or Going?

    Science.gov (United States)

    Erwin, Susan

    2005-01-01

    The purpose of this paper is to explore the possibility of using the principle of "superposition of states" (commonly illustrated by Schrodinger's Cat experiment) to understand the process of using standardized testing to measure a student's learning. Comparisons from literature, neuroscience, and Schema Theory will be used to expound upon the…

  3. The resident-intruder paradigm : a standardized test for aggression, violence and social stress

    NARCIS (Netherlands)

    Koolhaas, Jacob; Coppens, Caroline M.; de Boer, Sietse F.; Buwalda, Bauke; Meerlo, Peter; Timmermans, Paul J. A.

    2013-01-01

    This video publication explains in detail the experimental protocol of the resident-intruder paradigm in rats. This test is a standardized method to measure offensive aggression and defensive behavior in a semi natural setting. The most important behavioral elements performed by the resident and the

  4. Developing Effective Physical Fitness Testing Standards for Pre Service Physical Educators

    Science.gov (United States)

    Hill, Kory; Thornburg, Roland

    2016-01-01

    Physical educators are often held to a higher standard of physical fitness. The ability to effectively convey the importance of physical fitness may depend upon the ability to appear physically fit. The ability to perform at a minimal level of proficiency on fitness tests was deemed important by the faculty of one physical education teacher…

  5. Precision tests of the standard model, the Higgs, and new physics

    Indian Academy of Sciences (India)

    journal of. February 2004 physics pp. 149-161. Precision tests of the standard model, the Higgs, and new physics. GUIDO ALTARELLI. Theory Division, CERN ... the Pascos-Wolfenstein ratio of neutral to charged current deep inelastic cross- .... with the direct limit on СА can be improved with respect to the sM, even in the.

  6. Effects of Year-Round Schooling on Disadvantaged Students and the Distribution of Standardized Test Performance

    Science.gov (United States)

    Graves, Jennifer

    2011-01-01

    Using detailed longitudinal data for the state of California, this paper estimates the effect of year-round school calendars on nationally standardized test performance of traditionally disadvantaged students. The student subgroups studied in this paper are: low socioeconomic status, limited English proficiency, Hispanic and Latino, and African…

  7. Learning by Experience in a Standardized Testing Culture: Investigation of a Middle School Experiential Learning Program

    Science.gov (United States)

    Scogin, Stephen C.; Kruger, Christopher J.; Jekkals, Regan E.; Steinfeldt, Chelsea

    2017-01-01

    Standardized testing pressure sometimes discourages schools from broadly implementing experiential learning opportunities. However, some K-12 schools are challenging the trend with greater commitment to learning by experience. STREAM (science, technology, reading, engineering, arts, mathematics) school is a project-based program providing students…

  8. 9 CFR 147.1 - The standard tube agglutination test. 1

    Science.gov (United States)

    2010-01-01

    ... of clumps through a thin layer of absorbent cotton in a Buchner funnel with the aid of suction. The... absorbent cotton in a Buchner funnel with the aid of suction. The antigen then should be centrifuged. The... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false The standard tube agglutination test...

  9. The Fight's Not Always Fixed: Using Literary Response to Transcend Standardized Test Scores

    Science.gov (United States)

    Avila, JuliAnna

    2012-01-01

    In 2004, the National Endowment for the Arts (NEA) concluded that "literature reading is fading as a meaningful activity, especially among younger people." How can educators continue to teach students about the power of literary response when the priority is for them to achieve proficiency on standardized tests, whose scores can only be narrowly…

  10. Assessing Resilience in Students Who Are Deaf or Blind: Supplementing Standardized Achievement Testing

    Science.gov (United States)

    Butler, Michelle A.; Katayama, Andrew D.; Schindling, Casey; Dials, Katherine

    2018-01-01

    Although testing accommodations for standardized assessments are available for students with disabilities, interpretation remains challenging. The authors explored resilience to see if it could contribute to the interpretation of academic success for students who are deaf or hard of hearing or blind or have low vision. High school students (30…

  11. 40 CFR Appendix C to Subpart S of... - Steady-State Short Test Standards

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 2 2010-07-01 2010-07-01 false Steady-State Short Test Standards C Appendix C to Subpart S of Part 51 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED.../Maintenance Program Requirements Pt. 51, Subpt. S, App. C Appendix C to Subpart S of Part 51—Steady-State...

  12. Integrating GIS in the Middle School Curriculum: Impacts on Diverse Students' Standardized Test Scores

    Science.gov (United States)

    Goldstein, Donna; Alibrandi, Marsha

    2013-01-01

    This case study conducted with 1,425 middle school students in Palm Beach County, Florida, included a treatment group receiving GIS instruction (256) and a control group without GIS instruction (1,169). Quantitative analyses on standardized test scores indicated that inclusion of GIS in middle school curriculum had a significant effect on student…

  13. The Quest for Standard Tests in Prioritizing Water Use Rights in ...

    African Journals Online (AJOL)

    Zbelo Haileslassie

    agricultural uses, industrial uses for electricity production other industrial uses, aquaculture, recreational uses ... in this article as additional standard test.16 The case laws of United States and. English court cases are relevant ...... need for “… increasing production of export crops and food ...”.110 It accords first priority to the ...

  14. Wireless Sensor Network Congestion Control Based on Standard Particle Swarm Optimization and Single Neuron PID.

    Science.gov (United States)

    Yang, Xiaoping; Chen, Xueying; Xia, Riting; Qian, Zhihong

    2018-04-19

    Aiming at the problem of network congestion caused by the large number of data transmissions in wireless routing nodes of wireless sensor network (WSN), this paper puts forward an algorithm based on standard particle swarm⁻neural PID congestion control (PNPID). Firstly, PID control theory was applied to the queue management of wireless sensor nodes. Then, the self-learning and self-organizing ability of neurons was used to achieve online adjustment of weights to adjust the proportion, integral and differential parameters of the PID controller. Finally, the standard particle swarm optimization to neural PID (NPID) algorithm of initial values of proportion, integral and differential parameters and neuron learning rates were used for online optimization. This paper describes experiments and simulations which show that the PNPID algorithm effectively stabilized queue length near the expected value. At the same time, network performance, such as throughput and packet loss rate, was greatly improved, which alleviated network congestion and improved network QoS.

  15. Testing the accuracy of a Bayesian central-dose model for single-grain OSL, using known-age samples

    DEFF Research Database (Denmark)

    Guerin, Guillaume; Combès, Benoit; Lahaye, Christelle

    2015-01-01

    remains a difficult task, given the typically considerable dispersion in equivalent dose values measured by OSL - and the numerous sources of such dispersion in measurements. Here, we present the study of 19 samples for which independent age control is available, and whose ages range from 2 to 46ka. Based......-grain OSL and reference ages is about twice as large for the standard approach (12%) as with the Bayesian model (7%). Statistical tests show that, based on our (limited) dataset, the difference between the two models seems to be significant for samples in the age range 4-46ka. Finally, the influence...... on multi-grain OSL age estimates, these samples are presumed to have been both well-bleached at burial, and unaffected by mixing after deposition. Two ways of estimating single-grain ages are then compared: the standard approach on the one hand, consisting of applying the Central Age Model to De values...

  16. Guideline adherence to chemotherapy administration safety standards: a survey on nurses in a single institute

    OpenAIRE

    Kim, Kidong; Lee, Hee Sook; Kim, Younha; Kim, Beob-Jong; Kim, Moon-Hong; Choi, Seok-Cheol; Ryu, Sang-Young

    2011-01-01

    Objective Little is known about the guideline adherence of nurses to chemotherapy administration guidelines. We determined the guideline adherence of nurses to the Chemotherapy Administration Safety Standards and the relationship between demographic characteristics and guideline adherence. Methods Survey sheets containing two questions on demographic characteristics and 16 questions on the guideline adherence of nurses regarding chemotherapy administration were distributed to all in-patient d...

  17. The Method of Eichhorn with Non-Standard Projections for a Single Plate

    Science.gov (United States)

    Cardona, O.; Corona-Galindo, M.

    1990-11-01

    RESUMEN. Se desarrollan las expresiones para el metodo de Eichhorn en astrometria para proyecciones diferentes a la estandar. El se usa para obtener las coordenadas esfericas de estrellas en placas astron6micas cuando las variables contienen errores. ABSTRACT. We develop the expressions for the Eichhorn's Method in astrometry for non-standard projections. The method is used to obtain spherical coordinates of stars in astronomical plates, when all the variables have errors. Key words: ASTROMETRY

  18. Development of a reference material of a single DNA molecule for the quality control of PCR testing.

    Science.gov (United States)

    Mano, Junichi; Hatano, Shuko; Futo, Satoshi; Yoshii, Junji; Nakae, Hiroki; Naito, Shigehiro; Takabatake, Reona; Kitta, Kazumi

    2014-09-02

    We developed a reference material of a single DNA molecule with a specific nucleotide sequence. The double-strand linear DNA which has PCR target sequences at the both ends was prepared as a reference DNA molecule, and we named the PCR targets on each side as confirmation sequence and standard sequence. The highly diluted solution of the reference molecule was dispensed into 96 wells of a plastic PCR plate to make the average number of molecules in a well below one. Subsequently, the presence or absence of the reference molecule in each well was checked by real-time PCR targeting for the confirmation sequence. After an enzymatic treatment of the reaction mixture in the positive wells for the digestion of PCR products, the resultant solution was used as the reference material of a single DNA molecule with the standard sequence. PCR analyses revealed that the prepared samples included only one reference molecule with high probability. The single-molecule reference material developed in this study will be useful for the absolute evaluation of a detection limit of PCR-based testing methods, the quality control of PCR analyses, performance evaluations of PCR reagents and instruments, and the preparation of an accurate calibration curve for real-time PCR quantitation.

  19. Single Event Effects Test Facility Options at the Oak Ridge National Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Riemer, Bernie [ORNL; Gallmeier, Franz X [ORNL; Dominik, Laura J [ORNL

    2015-01-01

    Increasing use of microelectronics of ever diminishing feature size in avionics systems has led to a growing Single Event Effects (SEE) susceptibility arising from the highly ionizing interactions of cosmic rays and solar particles. Single event effects caused by atmospheric radiation have been recognized in recent years as a design issue for avionics equipment and systems. To ensure a system meets all its safety and reliability requirements, SEE induced upsets and potential system failures need to be considered, including testing of the components and systems in a neutron beam. Testing of integrated circuits (ICs) and systems for use in radiation environments requires the utilization of highly advanced laboratory facilities that can run evaluations on microcircuits for the effects of radiation. This paper provides a background of the atmospheric radiation phenomenon and the resulting single event effects, including single event upset (SEU) and latch up conditions. A study investigating requirements for future single event effect irradiation test facilities and developing options at the Spallation Neutron Source (SNS) is summarized. The relatively new SNS with its 1.0 GeV proton beam, typical operation of 5000 h per year, expertise in spallation neutron sources, user program infrastructure, and decades of useful life ahead is well suited for hosting a world-class SEE test facility in North America. Emphasis was put on testing of large avionics systems while still providing tunable high flux irradiation conditions for component tests. Makers of ground-based systems would also be served well by these facilities. Three options are described; the most capable, flexible, and highest-test-capacity option is a new stand-alone target station using about one kW of proton beam power on a gas-cooled tungsten target, with dual test enclosures. Less expensive options are also described.

  20. Ambiguity in measuring matrix diffusion with single-well injection/recovery tracer tests

    Science.gov (United States)

    Lessoff, S.C.; Konikow, Leonard F.

    1997-01-01

    Single-well injection/recovery tracer tests are considered for use in characterizing and quantifying matrix diffusion in dual-porosity aquifers. Numerical modeling indicates that neither regional drift in homogeneous aquifers, nor heterogeneity in aquifers having no regional drift, nor hydrodynamic dispersion significantly affects these tests. However, when drift is coupled simultaneously with heterogeneity, they can have significant confounding effects on tracer return. This synergistic effect of drift and heterogeneity may help explain irreversible flow and inconsistent results sometimes encountered in previous single-well injection/recovery tracer tests. Numerical results indicate that in a hypothetical single-well injection/recovery tracer test designed to demonstrate and measure dual-porosity characteristics in a fractured dolomite, the simultaneous effects of drift and heterogeneity sometimes yields responses similar to those anticipated in a homogeneous dual-porosity formation. In these cases, tracer recovery could provide a false indication of the occurrence of matrix diffusion. Shortening the shut-in period between injection and recovery periods may make the test less sensitive to drift. Using multiple tracers having different diffusion characteristics, multiple tests having different pumping schedules, and testing the formation at more than one location would decrease the ambiguity in the interpretation of test data.

  1. Standard test method for linear-elastic plane-strain fracture toughness KIc of metallic materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This test method covers the determination of fracture toughness (KIc) of metallic materials under predominantly linear-elastic, plane-strain conditions using fatigue precracked specimens having a thickness of 1.6 mm (0.063 in.) or greater subjected to slowly, or in special (elective) cases rapidly, increasing crack-displacement force. Details of test apparatus, specimen configuration, and experimental procedure are given in the Annexes. Note 1—Plane-strain fracture toughness tests of thinner materials that are sufficiently brittle (see 7.1) can be made using other types of specimens (1). There is no standard test method for such thin materials. 1.2 This test method is divided into two parts. The first part gives general recommendations and requirements for KIc testing. The second part consists of Annexes that give specific information on displacement gage and loading fixture design, special requirements for individual specimen configurations, and detailed procedures for fatigue precracking. Additional a...

  2. Standard test method for linear-elastic plane-strain fracture toughness KIc of metallic materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2013-01-01

    1.1 This test method covers the determination of fracture toughness (KIc) of metallic materials under predominantly linear-elastic, plane-strain conditions using fatigue precracked specimens having a thickness of 1.6 mm (0.063 in.) or greater subjected to slowly, or in special (elective) cases rapidly, increasing crack-displacement force. Details of test apparatus, specimen configuration, and experimental procedure are given in the Annexes. Note 1—Plane-strain fracture toughness tests of thinner materials that are sufficiently brittle (see 7.1) can be made using other types of specimens (1). There is no standard test method for such thin materials. 1.2 This test method is divided into two parts. The first part gives general recommendations and requirements for KIc testing. The second part consists of Annexes that give specific information on displacement gage and loading fixture design, special requirements for individual specimen configurations, and detailed procedures for fatigue precracking. Additional a...

  3. Comparative Performance of Four Single Extreme Outlier Discordancy Tests from Monte Carlo Simulations

    Directory of Open Access Journals (Sweden)

    Surendra P. Verma

    2014-01-01

    Full Text Available Using highly precise and accurate Monte Carlo simulations of 20,000,000 replications and 102 independent simulation experiments with extremely low simulation errors and total uncertainties, we evaluated the performance of four single outlier discordancy tests (Grubbs test N2, Dixon test N8, skewness test N14, and kurtosis test N15 for normal samples of sizes 5 to 20. Statistical contaminations of a single observation resulting from parameters called δ from ±0.1 up to ±20 for modeling the slippage of central tendency or ε from ±1.1 up to ±200 for slippage of dispersion, as well as no contamination (δ=0 and ε=±1, were simulated. Because of the use of precise and accurate random and normally distributed simulated data, very large replications, and a large number of independent experiments, this paper presents a novel approach for precise and accurate estimations of power functions of four popular discordancy tests and, therefore, should not be considered as a simple simulation exercise unrelated to probability and statistics. From both criteria of the Power of Test proposed by Hayes and Kinsella and the Test Performance Criterion of Barnett and Lewis, Dixon test N8 performs less well than the other three tests. The overall performance of these four tests could be summarized as N2≅N15>N14>N8.

  4. Validation of Proposed Metrics for Two-Body Abrasion Scratch Test Analysis Standards

    Science.gov (United States)

    Street, Kenneth W., Jr.; Kobrick, Ryan L.; Klaus, David M.

    2013-01-01

    Abrasion of mechanical components and fabrics by soil on Earth is typically minimized by the effects of atmosphere and water. Potentially abrasive particles lose sharp and pointed geometrical features through erosion. In environments where such erosion does not exist, such as the vacuum of the Moon, particles retain sharp geometries associated with fracturing of their parent particles by micrometeorite impacts. The relationship between hardness of the abrasive and that of the material being abraded is well understood, such that the abrasive ability of a material can be estimated as a function of the ratio of the hardness of the two interacting materials. Knowing the abrasive nature of an environment (abrasive)/construction material is crucial to designing durable equipment for use in such surroundings. The objective of this work was to evaluate a set of standardized metrics proposed for characterizing a surface that has been scratched from a two-body abrasion test. This is achieved by defining a new abrasion region termed Zone of Interaction (ZOI). The ZOI describes the full surface profile of all peaks and valleys, rather than just measuring a scratch width. The ZOI has been found to be at least twice the size of a standard width measurement; in some cases, considerably greater, indicating that at least half of the disturbed surface area would be neglected without this insight. The ZOI is used to calculate a more robust data set of volume measurements that can be used to computationally reconstruct a resultant profile for de tailed analysis. Documenting additional changes to various surface roughness par ameters also allows key material attributes of importance to ultimate design applications to be quantified, such as depth of penetration and final abraded surface roughness. Further - more, by investigating the use of custom scratch tips for specific needs, the usefulness of having an abrasion metric that can measure the displaced volume in this standardized

  5. Development of an ASTM standard glass durability test, the Product Consistency Test (PCT), for high level radioactive waste glass

    International Nuclear Information System (INIS)

    Jantzen, C.M.; Bibler, N.E.; Beam, D.C.; Ramsey, W.G.

    1994-01-01

    The nation's first, and the world's largest, facility to immobilize high-level nuclear waste in durable borosilicate glass has started operation at the Savannah River Site (SRS) in Aiken, South Carolina. The product specifications on the glass wasteform produced in the Defense Waste Processing Facility (DWPF) required extensive characterization of the glass product before actual production began and for continued characterization during production. To aid in this characterization, a glass durability (leach) test was needed that was easily reproducible, could be performed remotely on highly radioactive samples, and could yield results rapidly. Several standard leach tests were examined with a variety of test configurations. Using existing tests as a starting point, the DWPF Product Consistency Test (PCT was developed in which crushed glass samples are exposed to 90 ± 2 degree C deionized water for seven days. Based on extensive testing, including a seven-laboratory round robin and confirmatory testing with radioactive samples, the PCT is very reproducible, yields reliable results rapidly, and can be performed in shielded cell facilities with radioactive samples

  6. Testing of the large bore single aperture 1-meter superconducting dipoles made with phenolic inserts

    CERN Document Server

    Boschmann, H; Dubbeldam, R L; Kirby, G A; Lucas, J; Ostojic, R; Russenschuck, Stephan; Siemko, A; Taylor, T M; Vanenkov, I; Weterings, W

    1998-01-01

    Two identical single aperture 1-metre superconducting dipoles have been built in collaboration with HMA Power Systems and tested at CERN. The 87.8 mm aperture magnets feature a single layer coil wound using LHC main dipole outer layer cable, phenolic spacer type collars, and a keyed two part structural iron yoke. The magnets are designed as models of the D1 separation dipole in the LHC experimental insertions, whose nominal field is 4.5 T at 4.5 K. In this report we present the test results of the two magnets at 4.3 K and 1.9 K.

  7. The evolution of IRRR nuclear standards from the single failure criterion and their impact on system design

    International Nuclear Information System (INIS)

    Clark, D.H.

    1978-01-01

    One of the first industry standards developed in the United States to meet regulatory agency criteria for the design and installation of nuclear power plant control and instrumentation systems was prepared by the Institute of Electrical and Electronics Engineers, Inc., abbreviated IEEE. This was IEEE Std. 279, first issued in 1968. It was subsequently revised and reissued as IEEE Std. 279-1971 ''IEEE Standard: Criteria for Protection Systems for Nuclear Power Generating Stations''. Not only has the implementation of this standard had a tremendous impact on nuclear power plant design in the United States, it has been the base document from which subsequent IEEE nuclear standards have been developed. Three major concepts which are addressed by IEEE 279, and which have had a major impact upon control and instrumentation systems in nuclear power plants are the following : 1) Single failure criterion. 2) Equipment qualification. 3) Channel independence. Each of these concepts has resulted in the development of subsequent IEEE Nuclear Standards. The impact of some of these on control and instrumentation systems are discussed. (author)

  8. Crash tests of three identical low-wing single-engine airplane

    Science.gov (United States)

    Castle, C. B.; Alfaro-Bou, E.

    1983-01-01

    Three identical four place, low wing single engine airplane specimens with nominal masses of 1043 kg were crash tested under controlled free flight conditions. The tests were conducted at the same nominal velocity of 25 m/sec along the flight path. Two airplanes were crashed on a concrete surface (at 10 and 30 deg pitch angles), and one was crashed on soil (at a -30 deg pitch angle). The three tests revealed that the specimen in the -30 deg test on soil sustained massive structural damage in the engine compartment and fire wall. Also, the highest longitudinal cabin floor accelerations occurred in this test. Severe damage, but of lesser magnitude, occurred in the -30 deg test on concrete. The highest normal cabin floor accelerations occurred in this test. The least structural damage and lowest accelerations occurred in the 10 deg test on concrete.

  9. Bayesian analysis of longitudinal Johne's disease diagnostic data without a gold standard test

    DEFF Research Database (Denmark)

    Wang, C.; Turnbull, B.W.; Nielsen, Søren Saxmose

    2011-01-01

    A Bayesian methodology was developed based on a latent change-point model to evaluate the performance of milk ELISA and fecal culture tests for longitudinal Johne's disease diagnostic data. The situation of no perfect reference test was considered; that is, no “gold standard.” A change-point proc...... an area under the receiver operating characteristic curve (AUC) of 0.984, and is superior to the raw ELISA (AUC = 0.911) and fecal culture (sensitivity = 0.358, specificity = 0.980) tests for Johne's disease diagnosis....

  10. Standard test method for radiochemical determination of plutonium in Soil by alpha spectroscopy

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2011-01-01

    1.1 This test method covers the determination of plutonium in soils at levels of detection dependent on count time, sample size, detector, background, and tracer yield. This test method describes one acceptable approach to the determination of plutonium in soil. 1.2 This test method is designed for 10 g of soil, previously collected and treated as described in Practices C998 and C999, but sample sizes up to 50 g may be analyzed by this test method. This test method may not be able to completely dissolve all forms of plutonium in the soil matrix. 1.3 The values stated in SI units are to be regarded as standard. The values given in parentheses are for information only. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific hazard statements are given in Section 9.

  11. Standard Test Method for Stress-Corrosion of Titanium Alloys by Aircraft Engine Cleaning Materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2006-01-01

    1.1 This test method establishes a test procedure for determining the propensity of aircraft turbine engine cleaning and maintenance materials for causing stress corrosion cracking of titanium alloy parts. 1.2 The evaluation is conducted on representative titanium alloys by determining the effect of contact with cleaning and maintenance materials on tendency of prestressed titanium alloys to crack when subsequently heated to elevated temperatures. 1.3 Test conditions are based upon manufacturer's maximum recommended operating solution concentration. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific precautionary statements, see and .

  12. Standard practice for preparation and use of direct tension stress-corrosion test specimens

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1985-01-01

    1.1 This practice covers procedures for designing, preparing, and using ASTM standard tension test specimens for investigating susceptibility to stress-corrosion cracking. Axially loaded specimens may be stressed quantitatively with equipment for application of either a constant load, constant strain, or with a continuously increasing strain. 1.2 Tension test specimens are adaptable for testing a wide variety of product forms as well as parts joined by welding, riveting, or various other methods. 1.3 The exposure of specimens in a corrosive environment is treated only briefly because other standards are being prepared to deal with this aspect. Meanwhile, the investigator is referred to Practices G35, G36, G37, and G44, and to ASTM Special Technical Publication 425 (1).

  13. TR-PIV Performance Test for a Flow Field Measurement in a Single Rod Test Section

    Energy Technology Data Exchange (ETDEWEB)

    Park, Ju Yong; Shin, Chang Hwan; Lee, Chi Young; Oh, Dong Seok; In, Wang Kee [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2011-10-15

    For large enhancement of performance of Pressurized Water Reactor(PWR), dual-cooled fuel is being developed in Korea Atomic Energy Research Institute(KAERI). This nuclear fuel is a ring shape fuel which is different from conventional cylindrical nuclear fuel and cooling water flows both inner and outer channel. For this fuel, it widens the surface area. But it is bigger outer diameter of fuel rods. So, interval between fuel rods narrows. This because of outer channel flow is unstable. So, measurement of turbulence flow and perturbation that influence in heat transfer elevation is important.. To understand heat transfer characteristics by turbulence, measurement of flow perturbation element is necessary. To measure these turbulence characteristics, hot wire anemometer is widely used. However, it has many disadvantages such as low durability of prove, and big probe size. For these reasons, TR-PIV(Time-Resolved Particle Image Velocimetry) system is employed for better flow measurement in our research institute. TR-PIV system is consisted of laser system and high-speed camera that have high frequency. So, was judged that can measurement complicated turbulence flow and perturbation. In this paper, introduce TR-PIV system, and with results acquiring in single rod flow through this system, and wish to introduce about after this practical use plan

  14. TR-PIV Performance Test for a Flow Field Measurement in a Single Rod Test Section

    International Nuclear Information System (INIS)

    Park, Ju Yong; Shin, Chang Hwan; Lee, Chi Young; Oh, Dong Seok; In, Wang Kee

    2011-01-01

    For large enhancement of performance of Pressurized Water Reactor(PWR), dual-cooled fuel is being developed in Korea Atomic Energy Research Institute(KAERI). This nuclear fuel is a ring shape fuel which is different from conventional cylindrical nuclear fuel and cooling water flows both inner and outer channel. For this fuel, it widens the surface area. But it is bigger outer diameter of fuel rods. So, interval between fuel rods narrows. This because of outer channel flow is unstable. So, measurement of turbulence flow and perturbation that influence in heat transfer elevation is important.. To understand heat transfer characteristics by turbulence, measurement of flow perturbation element is necessary. To measure these turbulence characteristics, hot wire anemometer is widely used. However, it has many disadvantages such as low durability of prove, and big probe size. For these reasons, TR-PIV(Time-Resolved Particle Image Velocimetry) system is employed for better flow measurement in our research institute. TR-PIV system is consisted of laser system and high-speed camera that have high frequency. So, was judged that can measurement complicated turbulence flow and perturbation. In this paper, introduce TR-PIV system, and with results acquiring in single rod flow through this system, and wish to introduce about after this practical use plan

  15. Evaluating Upper-Body Strength and Power From a Single Test: The Ballistic Push-up.

    Science.gov (United States)

    Wang, Ran; Hoffman, Jay R; Sadres, Eliahu; Bartolomei, Sandro; Muddle, Tyler W D; Fukuda, David H; Stout, Jeffrey R

    2017-05-01

    Wang, R, Hoffman, JR, Sadres, E, Bartolomei, S, Muddle, TWD, Fukuda, DH, and Stout, JR. Evaluating upper-body strength and power from a single test: the ballistic push-up. J Strength Cond Res 31(5): 1338-1345, 2017-The purpose of this study was to examine the reliability of the ballistic push-up (BPU) exercise and to develop a prediction model for both maximal strength (1 repetition maximum [1RM]) in the bench press exercise and upper-body power. Sixty recreationally active men completed a 1RM bench press and 2 BPU assessments in 3 separate testing sessions. Peak and mean force, peak and mean rate of force development, net impulse, peak velocity, flight time, and peak and mean power were determined. Intraclass correlation coefficients were used to examine the reliability of the BPU. Stepwise linear regression was used to develop 1RM bench press and power prediction equations. Intraclass correlation coefficient's ranged from 0.849 to 0.971 for the BPU measurements. Multiple regression analysis provided the following 1RM bench press prediction equation: 1RM = 0.31 × Mean Force - 1.64 × Body Mass + 0.70 (R = 0.837, standard error of the estimate [SEE] = 11 kg); time-based power prediction equation: Peak Power = 11.0 × Body Mass + 2012.3 × Flight Time - 338.0 (R = 0.658, SEE = 150 W), Mean Power = 6.7 × Body Mass + 1004.4 × Flight Time - 224.6 (R = 0.664, SEE = 82 W); and velocity-based power prediction equation: Peak Power = 8.1 × Body Mass + 818.6 × Peak Velocity - 762.0 (R = 0.797, SEE = 115 W); Mean Power = 5.2 × Body Mass + 435.9 × Peak Velocity - 467.7 (R = 0.838, SEE = 57 W). The BPU is a reliable test for both upper-body strength and power. Results indicate that the mean force generated from the BPU can be used to predict 1RM bench press, whereas peak velocity and flight time measured during the BPU can be used to predict upper-body power. These findings support the potential use of the BPU as a valid method to evaluate upper-body strength and power.

  16. Standard practice for conducting wire-on-bolt test for atmospheric galvanic corrosion

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1999-01-01

    1.1 This practice covers the evaluation of atmospheric galvanic corrosion of any anodic material that can be made into a wire when in contact with a cathodic material that can be made into a threaded rod. 1.2 When certain materials are used for the anode and cathode, this practice has been used to rate the corrosivity of atmospheres. 1.3 The wire-on-bolt test was first described in 1955 (1), and has since been used extensively with standard materials to determine corrosivity of atmospheres under the names CLIMAT Test (CLassify Industrial and Marine ATmospheres) (2-5) and ATCORR (ATmospheric CORRosivity) (6-9). 1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations p...

  17. A Study on the Improvement of Safety Testing Standards and Methods for Mammography

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Seon Hyeong; Jung, Ah Young; Yong, Hwan Seok; Kim, Do Wan; Jang, Gi Won; Cha, Sang Hoon [Korean Institute for Accreditation of Medical Imaging, Seoul (Korea, Republic of); Jo, Sang Won [Dept. of Radiology, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of); Park, Ji Koon [Industry-Academic Cooperation Foundation, International University of Korea, Jinju (Korea, Republic of)

    2012-11-15

    To establish the improved national safety testing standards and methods for mammography. We investigated and compared the current status of mammographic equipment installation with the national and international safety and quality control programs and methods. We established and verified the draft for safety testing standards and methods. We propose that the investigations of the conductor system, hardware leakage radiation profile, illumination intensity test, comparison between X-ray and light photon exposure, X-ray dose exposure on the chest wall, compression equipment size, timing equipment, and the average effective radiation dose, should all be maintained as they are in the present state without any changes. However, the exposure radiation dose reproducibility, kVp and mAs, and the half value layer tests should be reconsidered and revised. Moreover, compression pressure and autonomic exposure control system (AEC) tests should be included as new criteria. Other parameter controls included in the phantom image analysis which overlap with total quality assurance should be excluded. We recommend that AEC and compression pressure tests should be included as new criteria and the methods for the exposure radiation dose reproducibility, kVp, and mAs, and half value layer tests should be reconsidered and revised.

  18. Standard test method for measurement of 235U fraction using enrichment meter principle

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 This test method covers the quantitative determination of the fraction of 235U in uranium using measurement of the 185.7 keV gamma-ray produced during the decay of 235U. 1.2 This test method is applicable to items containing homogeneous uranium-bearing materials of known chemical composition in which the compound is considered infinitely thick with respect to 185.7 keV gamma-rays. 1.3 This test method can be used for the entire range of 235U fraction as a weight percent, from depleted (0.2 % 235U) to highly enriched (97.5 % 235U). 1.4 Measurement of items that have not reached secular equilibrium between 238U and 234Th may not produce the stated bias when low-resolution detectors are used with the computational method listed in Annex A2. 1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.6 This standard may involve hazardous materials, operations, and equipment. This standard does not purport to address all of the safety co...

  19. Simpler standards for local performance examinations: the Yes/No Angoff and whole-test Ebel.

    Science.gov (United States)

    Yudkowsky, Rachel; Downing, Steven M; Wirth, Scott

    2008-01-01

    The whole-test Ebel and Yes/No Angoff methods offer the possibility of faster and easier standard-setting exercises for local, medium-stakes performance exams. We sought to establish if these less demanding methods might be substituted for the traditional but complex case-level Ebel. Six faculty judges each used all three methods to set standards for six standardized-patient checklists used for 178 fourth-year medical students. We compared the cut scores, passing rates, reliability, ease of use, and credibility of the three methods. The three methods produced roughly equivalent cut scores. Generalizability of judgments was .94 and .96 for the case-level and whole-test Ebel, and .76 for the Yes/No Angoff. Judges found the simplified methods more credible than the case-level Ebel. The Yes/No Angoff method was preferred by five of six judges. The whole-test Ebel and the Yes/No Angoff may be simple and realistic options for setting standards for local performance exams.

  20. Standard test method for Young's modulus, tangent modulus, and chord modulus

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2004-01-01

    1.1 This test method covers the determination of Young's modulus, tangent modulus, and chord modulus of structural materials. This test method is limited to materials in which and to temperatures and stresses at which creep is negligible compared to the strain produced immediately upon loading and to elastic behavior. 1.2 Because of experimental problems associated with the establishment of the origin of the stress-strain curve described in 8.1, the determination of the initial tangent modulus (that is, the slope of the stress-strain curve at the origin) and the secant modulus are outside the scope of this test method. 1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory require...

  1. Standard test method for measurement of roll wave optical distortion in heat-treated flat glass

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 This test method is applicable to the determination of the peak-to-valley depth and peak-to-peak distances of the out-of-plane deformation referred to as roll wave which occurs in flat, heat-treated architectural glass substrates processed in a heat processing continuous or oscillating conveyance oven. 1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.3 This test method does not address other flatness issues like edge kink, ream, pocket distortion, bow, or other distortions outside of roll wave as defined in this test method. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  2. Standard Test Method for Determining Thermal Performance of Tracking Concentrating Solar Collectors

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1987-01-01

    1.1 This test method covers the determination of thermal performance of tracking concentrating solar collectors that heat fluids for use in thermal systems. 1.2 This test method applies to one- or two-axis tracking reflecting concentrating collectors in which the fluid enters the collector through a single inlet and leaves the collector through a single outlet, and to those collectors where a single inlet and outlet can be effectively provided, such as into parallel inlets and outlets of multiple collector modules. 1.3 This test method is intended for those collectors whose design is such that the effects of diffuse irradiance on performance is negligible and whose performance can be characterized in terms of direct irradiance. Note 1—For purposes of clarification, this method shall apply to collectors with a geometric concentration ratio of seven or greater. 1.4 The collector may be tested either as a thermal collection subsystem where the effects of tracking errors have been essentially removed from t...

  3. A field test for companded single sideband modulation Implications for capacity enhancement and transmission planning

    Science.gov (United States)

    Wallace, E.; Adams, C.; Arnstein, D.

    A series of field tests of companded single sideband modulation (CSSB) technique for use in the Intelsat system is described. A 12-channel circuit group was tested between switches in Pittsburgh, and the Deutsche Bundespost (DBP) in Frankfurt via the Etam and Raisting satellite earth stations. A transponder bulk that included existing FDM-FM carriers was chosen to match the typical, Intelsat operating conditions, thus permitting the compatibility of FDM/FM and CSSB to be examined simultaneously. Results of objective performance tests are discussed, and a description of several subjective testing techniques is also given.

  4. Outcome of a standardized technique of preputial preservation surgery for phimosis: A single institutional experience

    Directory of Open Access Journals (Sweden)

    Kamalesh Pal

    2014-01-01

    Full Text Available Introduction: Pathological phimosis or preputial stenosis is a distressing problem in children leading to recurrent balanoposthitis, ballooning of prepuce, and rarely back pressure changes in the urinary tract. Circumcision has been the standard of care for such situations, although recently, various alternatives to circumcision have been reported in the literature. Most of these techniques are often complex and are met with poor acceptance. Moreover, besides personal preferences (in Hindus, advantages of preputial preservation is increasingly being realized recently. Materials and Methods: A prospective study was carried out in which a simple standardized technique of preputioplasty (dorsal slit was used in 40 pediatric preputial stenosis cases. The outcome of this procedure including cosmesis and parental satisfaction was evaluated. Results: The average duration of this procedure was from 10 to 25 min with no intraoperative complications. The cosmetic outcome was good in 62.5%, satisfactory in 30%, and poor in 7.5% of cases. All of the boys had retractable prepuce with no functional problems. There was 100% parental satisfaction. None of the patients required a redo procedure or circumcision. Conclusion: A dorsal slit of adequate length i.e.; 1/3 rd the length from the corona to the tip leads to a satisfactory cosmetic outcome in more than 92% of cases. Preputioplasty is a safe and simple alternative to more radical procedure of circumcision.

  5. Unpacking insanity defence standards: An experimental study of rationality and control tests in criminal law

    Directory of Open Access Journals (Sweden)

    Rebecca K. Helm

    2016-07-01

    Full Text Available The present study investigated the impact of different legal standards on mock juror decisions concerning whether a defendant was guilty or not guilty by reason of insanity. Undergraduate students (N = 477 read a simulated case summary involving a murder case and were asked to make an insanity determination. The cases differed in terms of the condition of the defendant (rationality deficit or control deficit and the legal standard given to the jurors to make the determination (Model Penal Code, McNaughten or McNaughten plus a separate control determination. The effects of these variables on the insanity determination were investigated. Jurors also completed questionnaires measuring individualism and hierarchy attitudes and perceptions of facts in the case. Results indicate that under current insanity standards jurors do not distinguish between defendants with rationality deficits and defendants with control deficits regardless of whether the legal standard requires them to do so. Even defendants who lacked control were found guilty at equal rates under a legal standard excusing rationality deficits only and a legal standard excluding control and rationality deficits. This was improved by adding a control test as a partial defence, to be determined after a rationality determination. Implications for the insanity defence in the Criminal Justice System are discussed.

  6. Field-testing the WHO child growth standards in four countries.

    Science.gov (United States)

    Onyango, Adelheid W; de Onis, Mercedes; Caroli, Margherita; Shah, Uzma; Sguassero, Yanina; Redondo, Nora; Carroli, Berenise

    2007-01-01

    In April 2006 the WHO released a set of growth standards for children from birth to the age of 5 y. Prior to their release, the standards were field-tested in 4 countries. The main objective was to compare children's length/height-for-age and weight-for-length/height based on the new standards with clinician assessments of the same children. The study sampled children Argentina and Italy) and 2 less-affluent ones (Maldives and Pakistan). Length/height and weight were measured by doctors and epidemiologists who also recorded a clinical assessment of each child's length/height in relation to age and weight relative to length/height. Anthropometric indicators of nutritional status were generated based on the WHO standards. As expected, Pakistan and the Maldives had higher rates of stunting, wasting, and underweight than Italy and Argentina, and the reverse was true for overweight and obesity. Where stunting was prevalent, the children classified as short were a mean children classified as thin were indeed wasted (<-2 SD for weight-for-height) and a positive association in trend was evident between weight-for-height and the line-up of groups from thin to obese. The overall concordance between clinical assessments and the WHO standards-based indicators attested to the clinical soundness of the standards.

  7. Philippine National Standards PNS 146:1987. Qualification and certification of non-destructive testing personnel

    International Nuclear Information System (INIS)

    1987-01-01

    The National Coordinating Committee on Non-Destructive Testing (NCC-NDT) of the Philippine Atomic Energy Commission (PAEC) in collaboration with the Bureau of Products and Standards (BPS) adopted the following standard which contains 1) scope and field application, 2) abbreviations, 3) definitions, 4) level of competence, 5) general principles of certification, 6) eligibility for examination, 7) examination, 8) certification, 9) validity and renewal and, 10) files. It includes the following annexes: a) Requirements of technical knowledge of NDT personnel, b) Physical requirements and, c) Administration of examinations. (ELC)

  8. Standard test method for uranium and plutonium concentrations and isotopic abundances by thermal ionization mass spectrometry

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2005-01-01

    1.1 This test method covers the determination of the concentration and isotopic composition of uranium and plutonium in solutions. The purified uranium or plutonium from samples ranging from nuclear materials to environmental or bioassay matrices is loaded onto a mass spectrometric filament. The isotopic ratio is determined by thermal ionization mass spectrometry, the concentration is determined by isotope dilution. 1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish safety and health practices and determine the applicability of regulatory limitations prior to use.

  9. Towards standardized testing methodologies for optical properties of components in concentrating solar thermal power plants

    Science.gov (United States)

    Sallaberry, Fabienne; Fernández-García, Aránzazu; Lüpfert, Eckhard; Morales, Angel; Vicente, Gema San; Sutter, Florian

    2017-06-01

    Precise knowledge of the optical properties of the components used in the solar field of concentrating solar thermal power plants is primordial to ensure their optimum power production. Those properties are measured and evaluated by different techniques and equipment, in laboratory conditions and/or in the field. Standards for such measurements and international consensus for the appropriate techniques are in preparation. The reference materials used as a standard for the calibration of the equipment are under discussion. This paper summarizes current testing methodologies and guidelines for the characterization of optical properties of solar mirrors and absorbers.

  10. Achieving Innovation and Affordability Through Standardization of Materials Development and Testing

    Science.gov (United States)

    Bray, M. H.; Zook, L. M.; Raley, R. E.; Chapman, C.

    2011-01-01

    The successful expansion of development, innovation, and production within the aeronautics industry during the 20th century was facilitated by collaboration of government agencies with the commercial aviation companies. One of the initial products conceived from the collaboration was the ANC-5 Bulletin, first published in 1937. The ANC-5 Bulletin had intended to standardize the requirements of various government agencies in the design of aircraft structure. The national space policy shift in priority for NASA with an emphasis on transferring the travel to low earth orbit to commercial space providers highlights an opportunity and a need for the national and global space industries. The same collaboration and standardization that is documented and maintained by the industry within MIL-HDBK-5 (MMPDS-01) and MIL-HBDK-17 (nonmetallic mechanical properties) can also be exploited to standardize the thermal performance properties, processing methods, test methods, and analytical methods for use in aircraft and spacecraft design and associated propulsion systems. In addition to the definition of thermal performance description and standardization, the standardization for test methods and analysis for extreme environments (high temperature, cryogenics, deep space radiation, etc) would also be highly valuable to the industry. Its subsequent revisions and conversion to MIL-HDBK-5 and then MMPDS-01 established and then expanded to contain standardized mechanical property design values and other related design information for metallic materials used in aircraft, missiles, and space vehicles. It also includes guidance on standardization of composition, processing, and analytical methods for presentation and inclusion into the handbook. This standardization enabled an expansion of the technologies to provide efficiency and reliability to the consumers. It can be established that many individual programs within the government agencies have been overcome with development costs

  11. The anomaly in a breakthrough curve of a single well "push-pull" tracer test: A density driven effect?

    Science.gov (United States)

    Zeilfelder, Sarah; Hebig, Klaus; Ito, Narimitsu; Machida, Isao; Scheytt, Traugott; Marui, Atsunao

    2013-04-01

    What method is appropriate to investigate an aquifer when there is only one well available? A single well "push-pull" tracer test (PP Test) may be a suitable method in order to characterize an aquifer and to obtain information about the hydraulic and chemical properties when only one well is available for the investigations. In a PP test, a test solution that contains a known amount of solutes and a conservative tracer is injected into the aquifer ("push") and extracted afterwards ("pull"). Optionally, the test solution is flushed out of the well and the casing with untreated test solution with a so called "chaser" before being extracted. Also between the injection and the extraction phase a drifting time may be included. The breakthrough of the tracer during the extraction phase is measured and used for analyses and interpretation. In the last three years, several PP Test campaigns were conducted at two different test sites in Japan (Hebig et al. 2011, Zeilfelder et al. 2012). The aim was to investigate the applicability of the PP Test method in different geological settings and in different types of aquifers. The latest field campaign thus focussed on the question how variations of the setup are influencing the breakthrough curve of the PP Test in order to develop and enhance this method. Also the standardization of the PP Test was an aim of this study. During the campaign, a total of seven PP Tests were performed, while only single aspects of the setup were varied from test to test. The tests differed in injection and extraction rate, in the salinity of the injected test solution and in the use of a chaser solution. The general shapes of the breakthrough curves were similar and conclusions about the repeatability of the PP Test could be drawn. However, a sharp anomaly was observed in the breakthrough curve of one specific setup type. By repeating this PP test under the same boundary conditions, we were able to recreate the anomaly and could exclude any technical

  12. Electric Vehicle Communications Standards Testing and Validation - Phase II: SAE J2931/1

    Energy Technology Data Exchange (ETDEWEB)

    Pratt, Richard M. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Gowri, Krishnan [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2013-01-15

    Vehicle to grid communication standards enable interoperability among vehicles, charging stations and utility providers and provide the capability to implement charge management. Several standards initiatives by the Society of Automobile Engineers (SAE), International Standards Organization and International Electrotechnical Commission (ISO/IEC), and ZigBee/HomePlug Alliance are developing requirements for communication messages and protocols. Recent work by the Electric Power Research Institute (EPRI) in collaboration with SAE and automobile manufacturers has identified vehicle to grid communication performance requirements and developed a test plan as part of SAE J2931/1 committee work. This laboratory test plan was approved by the SAE J2931/1 committee and included test configurations, test methods, and performance requirements to verify reliability, robustness, repeatability, maximum communication distance, and authentication features of power line carrier (PLC) communication modules at the internet protocol layer level. The goal of the testing effort was to select a communication technology that would enable automobile manufacturers to begin the development and implementation process. The EPRI/Argonne National Laboratory (ANL)/Pacific Northwest National Laboratory (PNNL) testing teams divided the testing so that results for each test could be presented by two teams, performing the tests independently. The PNNL team performed narrowband PLC testing including the Texas Instruments (TI) Concerto, Ariane Controls AC-CPM1, and the MAXIM Tahoe 2 evaluation boards. The scope of testing was limited to measuring the vendor systems communication performance between Electric Vehicle Support Equipment (EVSE) and plug-in electric vehicles (PEV). The testing scope did not address PEV’s CAN bus to PLC or PLC to EVSE (Wi-Fi, cellular, PLC Mains, etc.) communication integration. In particular, no evaluation was performed to delineate the effort needed to translate the IPv6

  13. Method for Estimating Evaporative Potential (IM/CLO) from ASTM Standard Single Wind Velocity Measures

    Science.gov (United States)

    2016-08-10

    Introduction .................................................................................................................. 2 Methods...testing. 2 INTRODUCTION Sweating thermal manikins have long been used to provide biophysical measures of clothing and equipment worn by the...AW, Gonzalez JA, and Xu X. Ebola response: Modeling the risk of heat stress from personal protective clothing. PLoS ONE 10(11), e0143461, 2015. 16

  14. Meta-analysis for the comparison of two diagnostic tests to a common gold standard: A generalized linear mixed model approach.

    Science.gov (United States)

    Hoyer, Annika; Kuss, Oliver

    2016-08-02

    Meta-analysis of diagnostic studies is still a rapidly developing area of biostatistical research. Especially, there is an increasing interest in methods to compare different diagnostic tests to a common gold standard. Restricting to the case of two diagnostic tests, in these meta-analyses the parameters of interest are the differences of sensitivities and specificities (with their corresponding confidence intervals) between the two diagnostic tests while accounting for the various associations across single studies and between the two tests. We propose statistical models with a quadrivariate response (where sensitivity of test 1, specificity of test 1, sensitivity of test 2, and specificity of test 2 are the four responses) as a sensible approach to this task. Using a quadrivariate generalized linear mixed model naturally generalizes the common standard bivariate model of meta-analysis for a single diagnostic test. If information on several thresholds of the tests is available, the quadrivariate model can be further generalized to yield a comparison of full receiver operating characteristic (ROC) curves. We illustrate our model by an example where two screening methods for the diagnosis of type 2 diabetes are compared. © The Author(s) 2016.

  15. Standard Test Method for Half-Cell Potentials of Uncoated Reinforcing Steel in Concrete

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This test method covers the estimation of the electrical corrosion potential of uncoated reinforcing steel in field and laboratory concrete, for the purpose of determining the corrosion activity of the reinforcing steel. 1.2 This test method is limited by electrical circuitry. Concrete surface in building interiors and desert environments lose sufficient moisture so that the concrete resistivity becomes so high that special testing techniques not covered in this test method may be required (see 5.1.4.1). Concrete surfaces that are coated or treated with sealers may not provide an acceptable electrical circuit. The basic configuration of the electrical circuit is shown in Fig. 1. 1.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It ...

  16. In-flight and ground testing of single event upset sensitivity in static RAMs

    International Nuclear Information System (INIS)

    Johansson, K.; Dyreklev, P.; Granbom, B.; Calvet, C.; Fourtine, S.; Feuillatre, O.

    1998-01-01

    This paper presents the results from in-flight measurements of single event upsets (SEU) in static random access memories (SRAM) caused by the atmospheric radiation environment at aircraft altitudes. The memory devices were carried on commercial airlines at high altitude and mainly high latitudes. The SEUs were monitored by a Component Upset Test Equipment (CUTE), designed for this experiment. The in flight results are compared to ground based testing with neutrons from three different sources

  17. Hydrogeological study of single water conducting fracture using a crosshole hydraulic test apparatus

    International Nuclear Information System (INIS)

    Yamamoto, Hajime; Shimo, Michito; Yamamoto, Takuya

    1998-03-01

    The Crosshole Injection Test Apparatus has been constructed to evaluate the hydraulic properties and conditions, such as hydraulic conductivity and its anisotropy, storage coefficient, pore pressure etc. within a rock near a drift. The construction started in FY93 and completed on August FY96 as a set of equipments for the use of crosshole hydraulic test, which is composed of one injection borehole instrument, one observation borehole instrument and a set of on-ground instrument. In FY96, in-situ feasibility test was conducted at a 550 m level drift in Kamaishi In Situ Test Site which has been operated by PNC, and the performance of the equipment and its applicability to various types of injection method were confirmed. In this year, a hydrogeological investigation on the single water conducting fracture was conducted at a 250 m level drift in Kamaishi In Situ Test Site, using two boreholes, KCH-3 and KCH-4, both of which are 30 m depth and inclined by 45 degrees from the surface. Pressure responses at the KCH-3 borehole during the drilling of KCH-4 borehole, the results of Borehole TV logging and core observation indicated that a major conductive single-fracture was successfully isolated by the packers. As a result of a series of the single-hole and the crosshole tests (sinusoidal and constant flowrate test), the hydraulic parameters of the single-fracture (such as hydraulic conductivity and storage coefficient) were determined. This report shows all the test result, analysed data, and also describes the hydro-geological structure near the drift. (author)

  18. Single and double sexual standards in Finland, Estonia, and St. Petersburg.

    Science.gov (United States)

    Haavio-Mannila, Elina; Kontula, Osmo

    2003-02-01

    The sexual revolution and fight for gender equality began in the West during the 1960s but did not reach the Soviet Union until the late 1980s. Using survey data from nationally representative samples from Finland in 1971, 1992, and 1999 and from two former Soviet areas, Estonia in 2000 and St. Petersburg in 1996, we investigated the following: (a) differences across decades and countries in acceptance of the sexual double standard (SDS) in attitudes toward marital infidelity and women's initiating sex; and (b) the relationship between the SDS and sexual satisfaction. Results show that Finland in the 1990s was more egalitarian than Finland in 1971, St. Petersburg in 1996, or Estonia in 2000. Egalitarian sexual attitudes were positively related to sexual satisfaction.

  19. Developing a Standard Method of Test for Packaged, Solid-Desiccant Based Dehumidification Systems

    International Nuclear Information System (INIS)

    Sand, J.R.

    2001-01-01

    A draft Method of Test (MOT) has been proposed for packaged, air-to-air, desiccant-based dehumidifier systems that incorporate a thermally-regenerated desiccant material for dehumidification. This MOT is intended to function as the ''system'' testing and rating compliment to the desiccant ''component'' (desiccant wheels and/or cassettes) MOT (ASHRAE 1998) and rating standard (ARI 1998) already adopted by industry. This draft standard applies to ''packaged systems'' that: Use desiccants for dehumidification of conditioned air for buildings; Use heated air for regeneration of the desiccant material; Include fans for moving process and regeneration air; May include other system components for filtering, pre-cooling, post-cooling, or heating conditioned air; and May include other components for humidification of conditioned air. The proposed draft applies to four different system operating modes depending on whether outdoor or indoor air is used for process air and regeneration air streams . Only the ''ventilation'' mode which uses outdoor air for both process and regeneration inlets is evaluated in this paper. Performance of the dehumidification system is presented in terms that would be most familiar and useful to designers of building HVAC systems to facilitate integration of desiccant equipment with more conventional hardware. Parametric performance results from a modified, commercial desiccant dehumidifier undergoing laboratory testing were used as data input to evaluate the draft standard. Performance results calculated from this experimental input, results from an error-checking/heat-balance verification test built into the standard, and estimated comparisons between desiccant and similarly performing conventional dehumidification equipment are calculated and presented. Some variations in test procedures are suggested to aid in analytical assessment of individual component performance

  20. Reliability and validity of arm function assessment with standardized guidelines for the Fugl-Meyer Test, Action Research Arm Test and Box and Block Test: a multicentre study.

    Science.gov (United States)

    Platz, Thomas; Pinkowski, Cosima; van Wijck, Frederike; Kim, In-Ha; di Bella, Paolo; Johnson, Garth

    2005-06-01

    To establish: (1) inter-rater and test-retest reliability of standardized guidelines for the Fugl-Meyer upper limb section, Action Research Arm Test and Box and Block Test in patients with paresis secondary to stroke, multiple sclerosis or traumatic brain injury and (2) correlation between these arm motor scales and more general measures of impairment and activity limitation. Multicentre cohort study. Three European referral centres for neurorehabilitation. Thirty-seven stroke, 14 multiple sclerosis and five traumatic brain injury patients. Scores of the Fugl-Meyer Test (arm section), Action Research Arm Test, and Box and Block Test derived from video information. All three motor tests showed very high inter-rater and test-retest reliability (ICC and rho for main variables > 0.95). Correlation between the motor scales was very high (rho > 0.92). Motor scales correlated moderately highly with the Hemispheric Stroke Scale, a measure of impairment (rho = 0.660-0.689), but not with the Modified Barthel Index, a measure of the ability to cope with basic activities of daily living (rho = 0.044-0.086). The standardized guidelines assured comparability of test administration and scoring across clinical facilities. The arm motor scales provided information that was not identical to information from the Hemispheric Stroke Scale or the Modified Barthel Index.