WorldWideScience

Sample records for single serum samples

  1. High throughput and accurate serum proteome profiling by integrated sample preparation technology and single-run data independent mass spectrometry analysis.

    Science.gov (United States)

    Lin, Lin; Zheng, Jiaxin; Yu, Quan; Chen, Wendong; Xing, Jinchun; Chen, Chenxi; Tian, Ruijun

    2018-03-01

    Mass spectrometry (MS)-based serum proteome analysis is extremely challenging due to its high complexity and dynamic range of protein abundances. Developing high throughput and accurate serum proteomic profiling approach capable of analyzing large cohorts is urgently needed for biomarker discovery. Herein, we report a streamlined workflow for fast and accurate proteomic profiling from 1μL of blood serum. The workflow combined an integrated technique for highly sensitive and reproducible sample preparation and a new data-independent acquisition (DIA)-based MS method. Comparing with standard data dependent acquisition (DDA) approach, the optimized DIA method doubled the number of detected peptides and proteins with better reproducibility. Without protein immunodepletion and prefractionation, the single-run DIA analysis enables quantitative profiling of over 300 proteins with 50min gradient time. The quantified proteins span more than five orders of magnitude of abundance range and contain over 50 FDA-approved disease markers. The workflow allowed us to analyze 20 serum samples per day, with about 358 protein groups per sample being identified. A proof-of-concept study on renal cell carcinoma (RCC) serum samples confirmed the feasibility of the workflow for large scale serum proteomic profiling and disease-related biomarker discovery. Blood serum or plasma is the predominant specimen for clinical proteomic studies while the analysis is extremely challenging for its high complexity. Many efforts had been made in the past for serum proteomics for maximizing protein identifications, whereas few have been concerned with throughput and reproducibility. Here, we establish a rapid, robust and high reproducible DIA-based workflow for streamlined serum proteomic profiling from 1μL serum. The workflow doesn't need protein depletion and pre-fractionation, while still being able to detect disease-relevant proteins accurately. The workflow is promising in clinical application

  2. METABOLITE CHARACTERIZATION IN SERUM SAMPLES FROM ...

    African Journals Online (AJOL)

    Preferred Customer

    fasting 10 mL of blood sample from each individual was taken and was allowed to clot in plastic tube for 2 h at room temperature. The serum was collected by centrifugation. The samples were stored under liquid nitrogen for NMR analysis. Before NMR analysis, 600 µL of the samples were taken in a 5 mm high quality NMR ...

  3. Comparison of immunofluorescence and enzyme-linked immunosorbent assay and immunoglobulin G avidity techniques for screening of anti: Toxoplasma antibodies among single serum sample pregnant women in Tabriz, Iran

    Directory of Open Access Journals (Sweden)

    Mehrangiz Rajaii

    2015-01-01

    Full Text Available Background: Congenital toxoplasmosis is that pregnant women acquire the infection during gestation; diagnosis of the acute infection during pregnancy is a complex subject of maternal toxoplasmosis. Thus, the presence of immunoglobulin G (IgG and/or IgM Toxoplasma antibodies in a single serum sample drawn during gestation cannot be used to define whether the infection was recently acquired or chronic. Materials and Methods: At this cross-sectional descriptive study, sera of 391 pregnant women examined and compared. They were in an age range of 21-35 years, referred by gynecologists and infectious disease specialists, during March 2012-April 2013. They have referred, 215 (54.98%, 102 (26%, 74 (18.92% in the first, second and third trimesters of gestation, respectively. For each of them, a questionnaire was completed and serum samples were prepared in an equal condition, examined according to the procedures of indirect immunofluorescence (IIF, enzyme-linked immunosorbent assay (ELISA and IgG Avidity techniques. Results: We have found 111 (28.38% seronegative and 280 (71.61% seropositive cases by IIF and 124 (31.70% seronegative, 267 (68.28% seropositive cases by ELISA. The IgG avidity test confirmed 45 (69.23% and 7 (10.76% doubtful cases of IgM test in IIF and ELISA techniques. Conclusions: This study highlights how to manage pregnant women with toxoplasmosis, especially in a single serum sample condition.

  4. Analytical Bias Exceeding Desirable Quality Goal in 4 out of 5 Common Immunoassays: Results of a Native Single Serum Sample External Quality Assessment Program for Cobalamin, Folate, Ferritin, Thyroid-Stimulating Hormone, and Free T4 Analyses.

    Science.gov (United States)

    Kristensen, Gunn B B; Rustad, Pål; Berg, Jens P; Aakre, Kristin M

    2016-09-01

    We undertook this study to evaluate method differences for 5 components analyzed by immunoassays, to explore whether the use of method-dependent reference intervals may compensate for method differences, and to investigate commutability of external quality assessment (EQA) materials. Twenty fresh native single serum samples, a fresh native serum pool, Nordic Federation of Clinical Chemistry Reference Serum X (serum X) (serum pool), and 2 EQA materials were sent to 38 laboratories for measurement of cobalamin, folate, ferritin, free T4, and thyroid-stimulating hormone (TSH) by 5 different measurement procedures [Roche Cobas (n = 15), Roche Modular (n = 4), Abbott Architect (n = 8), Beckman Coulter Unicel (n = 2), and Siemens ADVIA Centaur (n = 9)]. The target value for each component was calculated based on the mean of method means or measured by a reference measurement procedure (free T4). Quality specifications were based on biological variation. Local reference intervals were reported from all laboratories. Method differences that exceeded acceptable bias were found for all components except folate. Free T4 differences from the uncommonly used reference measurement procedure were large. Reference intervals differed between measurement procedures but also within 1 measurement procedure. The serum X material was commutable for all components and measurement procedures, whereas the EQA materials were noncommutable in 13 of 50 occasions (5 components, 5 methods, 2 EQA materials). The bias between the measurement procedures was unacceptably large in 4/5 tested components. Traceability to reference materials as claimed by the manufacturers did not lead to acceptable harmonization. Adjustment of reference intervals in accordance with method differences and use of commutable EQA samples are not implemented commonly. © 2016 American Association for Clinical Chemistry.

  5. METABOLITE CHARACTERIZATION IN SERUM SAMPLES FROM ...

    African Journals Online (AJOL)

    Preferred Customer

    and 13C chemical shifts is given in Table 1. Table 1. Resonance assignments of most significant metabolites of serum control healthy samples. S. No Metabolite. Group. 1H shift 13C shift Multiplicities. 1 Fatty acids. CH3. 0.90. 19.7 t. 2 Isoleucine. δCH3. 0.94. 13.8 t. 3 Leucine. δCH3. 0.95. 23.5 d. 4 Leucine. δCH3. 0.96. 24.7.

  6. Proteome profiling analysis of human ovarian cancer serum samples

    International Nuclear Information System (INIS)

    Cognetti, F.; Citro, G.

    2009-01-01

    Mass Spectrometry represents a powerful tool in cancer research to discovery of potential bio markers through peak identification from serum profiling. By using high resolution MALDITOF and bioinformatic analysis almost 400 serum sample homogeneously distributed between biopsy confirmed ovarian cancer and high risk serum samples were analyzed. Each serum sample run in duplicate and whole serum sample preparation procedure has been performed by Hamilton Star Robot in order to reduce bias and the replicates with a low Pearson coefficient are removed. After automated reverse phase magnetic beads separation the samples were tested in MALDI-TOF

  7. Radioenzymatic assay for trimethoprim in very small serum samples

    International Nuclear Information System (INIS)

    Yogev, R.; Melick, C.; Tan-Pong, L.

    1985-01-01

    A modification of the methotrexate radioassay kit (supplied by New England Enzyme Center) enabled determination of trimethoprim levels in 5-microliter serum samples. An excellent correlation between this assay and high-pressure liquid chromatography assay was found. These preliminary results suggest that with this method rapid determination of trimethoprim levels in very small samples (5 to 10 microliters) can be achieved

  8. Serum Dried Samples to Detect Dengue Antibodies: A Field Study

    Science.gov (United States)

    Maldonado-Rodríguez, Angelica; Rojas-Montes, Othon; Chavez-Negrete, Adolfo; Rojas-Uribe, Magdalena; Posadas-Mondragon, Araceli; Aguilar-Faisal, Leopoldo; Xoconostle-Cazares, Beatriz

    2017-01-01

    Background Dried blood and serum samples are useful resources for detecting antiviral antibodies. The conditions for elution of the sample need to be optimized for each disease. Dengue is a widespread disease in Mexico which requires continuous surveillance. In this study, we standardized and validated a protocol for the specific detection of dengue antibodies from dried serum spots (DSSs). Methods Paired serum and DSS samples from 66 suspected cases of dengue were collected in a clinic in Veracruz, Mexico. Samples were sent to our laboratory, where the conditions for optimal elution of DSSs were established. The presence of anti-dengue antibodies was determined in the paired samples. Results DSS elution conditions were standardized as follows: 1 h at 4°C in 200 µl of DNase-, RNase-, and protease-free PBS (1x). The optimal volume of DSS eluate to be used in the IgG assay was 40 µl. Sensitivity of 94%, specificity of 93.3%, and kappa concordance of 0.87 were obtained when comparing the antidengue reactivity between DSSs and serum samples. Conclusion DSS samples are useful for detecting anti-dengue IgG antibodies in the field. PMID:28630868

  9. Serum Dried Samples to Detect Dengue Antibodies: A Field Study

    Directory of Open Access Journals (Sweden)

    Angelica Maldonado-Rodríguez

    2017-01-01

    Full Text Available Background. Dried blood and serum samples are useful resources for detecting antiviral antibodies. The conditions for elution of the sample need to be optimized for each disease. Dengue is a widespread disease in Mexico which requires continuous surveillance. In this study, we standardized and validated a protocol for the specific detection of dengue antibodies from dried serum spots (DSSs. Methods. Paired serum and DSS samples from 66 suspected cases of dengue were collected in a clinic in Veracruz, Mexico. Samples were sent to our laboratory, where the conditions for optimal elution of DSSs were established. The presence of anti-dengue antibodies was determined in the paired samples. Results. DSS elution conditions were standardized as follows: 1 h at 4°C in 200 µl of DNase-, RNase-, and protease-free PBS (1x. The optimal volume of DSS eluate to be used in the IgG assay was 40 µl. Sensitivity of 94%, specificity of 93.3%, and kappa concordance of 0.87 were obtained when comparing the antidengue reactivity between DSSs and serum samples. Conclusion. DSS samples are useful for detecting anti-dengue IgG antibodies in the field.

  10. Native human serum amyloid P component is a single pentamer

    DEFF Research Database (Denmark)

    Sørensen, Inge Juul; Andersen, Ove; Nielsen, EH

    1995-01-01

    Serum amyloid P component (SAP) and C-reactive protein (CRP) are members of the pentraxin protein family. SAP is the precursor protein to amyloid P component present in all forms of amyloidosis. The prevailing notion is that SAP in circulation has the form of a double pentameric molecule (decamer...... by rocket immunoelectrophoresis and electron microscopy. Thus, electron micrographs of purified SAP showed a predominance of decamers. However, the decamer form of SAP reversed to single pentamers when purified SAP was incorporated into SAP-depleted serum....

  11. Genotyping of Single Nucleotide Polymorphisms in DNA Isolated from Serum Using Sequenom MassARRAY Technology.

    Directory of Open Access Journals (Sweden)

    Tess V Clendenen

    Full Text Available Large epidemiologic studies have the potential to make valuable contributions to the assessment of gene-environment interactions because they prospectively collected detailed exposure data. Some of these studies, however, have only serum or plasma samples as a low quantity source of DNA.We examined whether DNA isolated from serum can be used to reliably and accurately genotype single nucleotide polymorphisms (SNPs using Sequenom multiplex SNP genotyping technology. We genotyped 81 SNPs using samples from 158 participants in the NYU Women's Health Study. Each participant had DNA from serum and at least one paired DNA sample isolated from a high quality source of DNA, i.e. clots and/or cell precipitates, for comparison.We observed that 60 of the 81 SNPs (74% had high call frequencies (≥95% using DNA from serum, only slightly lower than the 85% of SNPs with high call frequencies in DNA from clots or cell precipitates. Of the 57 SNPs with high call frequencies for serum, clot, and cell precipitate DNA, 54 (95% had highly concordant (>98% genotype calls across all three sample types. High purity was not a critical factor to successful genotyping.Our results suggest that this multiplex SNP genotyping method can be used reliably on DNA from serum in large-scale epidemiologic studies.

  12. Spectrophotometric assay of creatinine in human serum sample

    Directory of Open Access Journals (Sweden)

    Avinash Krishnegowda

    2017-05-01

    Full Text Available A new spectrophotometric method for the analysis of creatinine concentration in human serum samples is developed. The method explores the oxidation of p-methylamino phenol sulfate (Metol in the presence of copper sulfate and creatinine which yields an intense violet colored species with maximum absorbance at 530 nm. The calibration graph of creatinine by fixed time assay ranged from 4.4 to 620 μM. Recovery of creatinine in human serum samples varied from 101% to 106%. Limit of detection and limit of quantification were 0.145 μM and 0.487 μM respectively. Sandell’s sensitivity was 0.112 μg cm−2 and molar absorptivity was 0.101 × 104 L mol−1 cm−1. Within day precision was 2.5–4.8% and day-to-day precision range was 3.2–7.8%. The robustness and ruggedness of the method expressed in RSD values ranged from 0.78% to 2.12% and 1.32% to 3.46% respectively, suggesting that the developed method was rugged. This method provides good sensitivity and is comparable to standard Jaffe’s method with comparatively less interference from foreign substances.

  13. Spectrofluorimetric Determination of Doxorubicin in Spiked Serum and Urine Samples

    Directory of Open Access Journals (Sweden)

    Jamshid L. Manzoori

    2014-12-01

    Full Text Available .A simple spectrofluorimetric method is described for the determination of doxorubicin (DXR based on its quenching effect on the fluorescence intensity of Tb3+- deferasirox (DFX complex as a fluorescent probe. The excitation and emission wavelengths were 328 and 545 nm, respectively. The effects of pH, time, order of addition of reagents, concentrations of Tb3+ and DFX and the buffer volume on the quenched fluorescence intensity were investigated and optimized. In the optimum conditions, the decrease of the fluorescence intensity of the system showed a good linear relationship with the concentration of DXR in the range of 20-1000 μg L-1, with a correlation coefficient 0.998. The detection limit (3s was 6.1 μg L-1 and the relative standard deviation for four replicate determinations of different concentrations of DXR was in the range of 1.7–4.4%. The procedure was successfully applied to the determination of doxorubicin in urine and serum samples

  14. Reproducibility of Serum Potassium Values in Serum From Blood Samples Stored for Increasing Times Prior to Centrifugation and Analysis.

    Science.gov (United States)

    Harper, Aaron; Lu, Chuanyong; Sun, Yi; Garcia, Rafael; Rets, Anton; Alexis, Herol; Saad, Heba; Eid, Ikram; Harris, Loretta; Marshall, Barbara; Tafani, Edlira; Pincus, Matthew R

    2016-05-01

    The goal of this work was to determine if immediate versus postponed centrifugation of samples affects the levels of serum potassium. Twenty participants donated normal venous blood that was collected in four serum separator tubes per donor, each of which was analyzed at 0, 1, 2, or 4 hr on the Siemens Advia 1800 autoanalyzer. Coefficients of variation (CVs) for potassium levels ranged from 0% to 7.6% with a mean of 3 ± 2%. ANOVA testing of the means for all 20 samples showed a P-value of 0.72 (>0.05) indicating that there was no statistically significant difference between the means of the samples at the four time points. Sixteen samples were found to have CVs that were ≤5%. Two samples showed increases of potassium from the reference range to levels higher than the upper reference limit, one of which had a 4-hr value that was within the reference or normal range (3.5-5 mEq/l). Overall, most samples were found to have reproducible levels of serum potassium. Serum potassium levels from stored whole blood collected in serum separator tubes are, for the most part, stable at room temperature for at least 4 hr prior to analysis. However, some samples can exhibit significant fluctuations of values. © 2015 Wiley Periodicals, Inc.

  15. Immunological Fingerprinting Method for Differentiation of Serum Samples in Research-Oriented Biobanks▿

    Science.gov (United States)

    Beaumont, Katy; Betsou, Fotini

    2010-01-01

    An immunoenzymatic serum fingerprinting method was developed to establish a serum sample fingerprint based on IgG titers obtained with three different antigens. Three widely expressed antigens were selected for their capacity to induce long-lasting humoral immune responses. This fingerprinting method may be used to differentiate between two serum samples and to determine whether they come from the same primary blood specimen. The method showed a specificity of 99.5%. This method is suitable as a quality control method for biobanked serum samples. PMID:20164255

  16. Serum and Urine Concentrations of Flunitrazepam and Metabolites, after a Single Oral Dose, by Immunoassay and GC-MS

    OpenAIRE

    Snyder, H.; Schwenzer, K.S.; Pearlman, R.; McNally, A.J.; Tsilimidos, M.; Salamone, S.J.; Brenneisen, R.; ElSohly, M.A.; Feng, S.; Brenneisen, R.

    2017-01-01

    A clinical study was conducted to assess the ability of commercially available immunoassays to detect flunitrazepam (FNP) in plasma and urine samples and to compare the results with those obtained by gas chromatography-mass spectrometry (GC-MS). The clinical study consisted of four individuals (two male and two female) who had taken a single 2-mg dose of FNP. Serum was collected over a 48-h period and urine was collected over a 72-h period. The serum and urine samples were analyzed by the COB...

  17. Native human serum amyloid P component is a single pentamer

    DEFF Research Database (Denmark)

    Sørensen, Inge Juul; Andersen, Ove; Nielsen, EH

    1995-01-01

    Serum amyloid P component (SAP) and C-reactive protein (CRP) are members of the pentraxin protein family. SAP is the precursor protein to amyloid P component present in all forms of amyloidosis. The prevailing notion is that SAP in circulation has the form of a double pentameric molecule (decamer...

  18. a comparison between the use of single and composite samples

    African Journals Online (AJOL)

    Dr F Neser

    A comparison between single and composite milk samples for the genetic evaluation of milk composition in dairy cattle ... Dairy Cattle Performance Testing Scheme replaced composite sampling with a single sample in 1995. The implementation of the new Scheme was ... Materials and methods. To obtain information on the ...

  19. Effects of blood sample handling procedures on measurable inflammatory markers in plasma, serum and dried blood spot samples

    DEFF Research Database (Denmark)

    Skogstrand, K.; Thorsen, P.; Vogel, I.

    2008-01-01

    , and 30 days at the same temperatures. 27 inflammatory markers in serum and plasma and 25 markers in DBSS were measured by a previously validated multiplex sandwich immunoassay using Luminex xMAP technology. The measurable concentrations of several cytokines in serum and plasma were significantly......The interests in monitoring inflammation by immunoassay determination of blood inflammatory markers call for information on the stability of these markers in relation to the handling of blood samples. The increasing use of stored biobank samples for such ventures that may have been collected...... increased when blood samples were stored for a period of time before the centrifugation, for certain cytokines more than 1000 fold compared to serum and plasma isolated and frozen immediately after venepuncture. The concentrations in serum generally increased more than in plasma. The measurable...

  20. Effects of blood sample handling procedures on measurable inflammatory markers in plasma, serum and dried blood spot samples

    DEFF Research Database (Denmark)

    Skogstrand, K.; Thorsen, P.; Vogel, I.

    2008-01-01

    increased when blood samples were stored for a period of time before the centrifugation, for certain cytokines more than 1000 fold compared to serum and plasma isolated and frozen immediately after venepuncture. The concentrations in serum generally increased more than in plasma. The measurable......The interests in monitoring inflammation by immunoassay determination of blood inflammatory markers call for information on the stability of these markers in relation to the handling of blood samples. The increasing use of stored biobank samples for such ventures that may have been collected...... and stored for other purposes, justifies the study hereof. Blood samples were stored for 0, 4, 24, and 48 h at 4 degrees C, room temperature (RT), and at 35 degrees C, respectively, before they were separated into serum or plasma and frozen. Dried blood spot samples (DBSS) were stored for 0, 1, 2, 3, 7...

  1. Serum tocopherol levels in very preterm infants after a single dose of vitamin E at birth.

    Science.gov (United States)

    Bell, Edward F; Hansen, Nellie I; Brion, Luc P; Ehrenkranz, Richard A; Kennedy, Kathleen A; Walsh, Michele C; Shankaran, Seetha; Acarregui, Michael J; Johnson, Karen J; Hale, Ellen C; Messina, Lynn A; Crawford, Margaret M; Laptook, Abbot R; Goldberg, Ronald N; Van Meurs, Krisa P; Carlo, Waldemar A; Poindexter, Brenda B; Faix, Roger G; Carlton, David P; Watterberg, Kristi L; Ellsbury, Dan L; Das, Abhik; Higgins, Rosemary D

    2013-12-01

    Our aim was to examine the impact of a single enteral dose of vitamin E on serum tocopherol levels. The study was undertaken to see whether a single dose of vitamin E soon after birth can rapidly increase the low α-tocopherol levels seen in very preterm infants. If so, this intervention could be tested as a means of reducing the risk of intracranial hemorrhage. Ninety-three infants vitamin E or placebo by gastric tube within 4 hours of birth. The vitamin E group received 50 IU/kg of vitamin E as dl-α-tocopheryl acetate (Aquasol E). The placebo group received sterile water. Blood samples were taken for measurement of serum tocopherol levels by high-performance liquid chromatography before dosing and 24 hours and 7 days after dosing. Eighty-eight infants received the study drug and were included in the analyses. The α-tocopherol levels were similar between the groups at baseline but higher in the vitamin E group at 24 hours (median 0.63 mg/dL vs. 0.42 mg/dL, P = .003) and 7 days (2.21 mg/dL vs 1.86 mg/dL, P = .04). There were no differences between groups in γ-tocopherol levels. At 24 hours, 30% of vitamin E infants and 62% of placebo infants had α-tocopherol levels vitamin E raised serum α-tocopherol levels, but to consistently achieve α-tocopherol levels >0.5 mg/dL, a higher dose or several doses of vitamin E may be needed.

  2. Clinical, radiological and molecular diagnosis correlation in serum samples from patients with osteoarticular tuberculosis

    Directory of Open Access Journals (Sweden)

    Guadalupe García-Elorriaga

    2014-07-01

    Conclusions: Nested PCR in serum samples is a rapid, highly sensitive and specific modality for OTB detection. PCR should be performed in addition to clinical evaluation, imaging studies, acid-fast bacilli staining, culture and histopathology diagnosis, if possible.

  3. Pre-analytical sample quality: metabolite ratios as an intrinsic marker for prolonged room temperature exposure of serum samples.

    Directory of Open Access Journals (Sweden)

    Gabriele Anton

    Full Text Available Advances in the "omics" field bring about the need for a high number of good quality samples. Many omics studies take advantage of biobanked samples to meet this need. Most of the laboratory errors occur in the pre-analytical phase. Therefore evidence-based standard operating procedures for the pre-analytical phase as well as markers to distinguish between 'good' and 'bad' quality samples taking into account the desired downstream analysis are urgently needed. We studied concentration changes of metabolites in serum samples due to pre-storage handling conditions as well as due to repeated freeze-thaw cycles. We collected fasting serum samples and subjected aliquots to up to four freeze-thaw cycles and to pre-storage handling delays of 12, 24 and 36 hours at room temperature (RT and on wet and dry ice. For each treated aliquot, we quantified 127 metabolites through a targeted metabolomics approach. We found a clear signature of degradation in samples kept at RT. Storage on wet ice led to less pronounced concentration changes. 24 metabolites showed significant concentration changes at RT. In 22 of these, changes were already visible after only 12 hours of storage delay. Especially pronounced were increases in lysophosphatidylcholines and decreases in phosphatidylcholines. We showed that the ratio between the concentrations of these molecule classes could serve as a measure to distinguish between 'good' and 'bad' quality samples in our study. In contrast, we found quite stable metabolite concentrations during up to four freeze-thaw cycles. We concluded that pre-analytical RT handling of serum samples should be strictly avoided and serum samples should always be handled on wet ice or in cooling devices after centrifugation. Moreover, serum samples should be frozen at or below -80°C as soon as possible after centrifugation.

  4. Evaluation of single whole inclusion serum test for IgG antibody to Chlamydia trachomatis in asymptomatic women.

    OpenAIRE

    Meyer, M P; Amortegui, A J

    1987-01-01

    IgG antibody titres against Chlamydia trachomatis were measured using a whole inclusion assay (Electro-Nucleonics Laboratories, Bethesda, Maryland, USA) in single serum samples of patients who presented for termination of pregnancy with evidence of infection with this organism (case group) and of 30 women with no evidence of infection (control group). Case and control patients were matched for age, race, marital status, history of sexually transmitted diseases, number of lifetime sexual partn...

  5. Native human serum amyloid P component is a single pentamer

    DEFF Research Database (Denmark)

    Sørensen, Inge Juul; Andersen, Ove; Nielsen, EH

    1995-01-01

    and ELISA, and SAP peak fractions were analysed by use of SDS-PAGE, Western blotting, and electron microscopy. The results indicate that native SAP circulates as a single pentamer, a part of which forms complexes with C4b-binding protein. The properties of SAP changed during purification as indicated...

  6. Scattering measurement of single particle for highly sensitive homogeneous detection of DNA in serum.

    Science.gov (United States)

    Zhu, Liang; Li, Guohua; He, Yonghong; Tan, Hui; Sun, Shuqing

    2018-02-01

    A highly sensitive homogeneous method for DNA detection has been developed. The system relies on two kinds of gold nanorod (AuNR) probes with complementary DNA sequences to the target DNA. In the presence of the target DNA, two kinds of AuNR probes are assembling into dimers or small aggregates. The target-induced AuNR aggregate has higher scattering intensity than that of a single AuNR because of the plasmonic coupling effect. Dark field microscopy was utilized to image the single particle and measure its scattering intensity. We wrote our own Matlab code and used it to extract the scattering signal of all particles. Difference in distribution of scattering intensity between the single AuNR and its aggregate provides a quantitative basis for the detection of target DNA. A linear dynamic range spanning from 0.1pM to 1nM and a detection limit of ~ 30fM were achieved for the detection of DNA in serum sample. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. A single-sampling hair trap for mesocarnivores

    Science.gov (United States)

    Jonathan N. Pauli; Matthew B. Hamilton; Edward B. Crain; Steven W. Buskirk

    2007-01-01

    Although techniques to analyze and quantifY DNA-based data have progressed, methods to noninvasively collect samples lag behind. Samples are generally collected from devices that permit coincident sampling of multiple individuals. Because of cross-contamination, substantive genotyping errors can arise. We developed a cost-effective (US$4.60/trap) single-capture hair...

  8. Comparative evaluation of blood and serum samples in rapid immunochromatographic tests for visceral leishmaniasis.

    Science.gov (United States)

    Kumar, Dinesh; Khanal, Basudha; Tiwary, Puja; Mudavath, Shyam Lal; Tiwary, Narendra K; Singh, Rupa; Koirala, Kanika; Boelaert, Marleen; Rijal, Suman; Sundar, Shyam

    2013-12-01

    Rapid diagnostic tests (RDTs) based on the detection of specific antibodies in serum are commonly used for the diagnosis of visceral leishmaniasis (VL). Several commercial kits are available, and some of them allow the use of whole-blood samples instead of serum. An RDT is much more user-friendly for blood samples than for serum samples. In this study, we examined the sensitivities and specificities of six different commercially available immunochromatographic tests for their accuracy in detecting Leishmania infection in whole blood and serum of parasitologically confirmed VL cases. This study was performed in areas of India and Nepal where VL is endemic. A total of 177 confirmed VL cases, 208 healthy controls from areas of endemicity (EHCs), 26 malaria patients (MP), and 37 tuberculosis (TB) patients were enrolled. The reproducibilities of the blood and serum results and between-reader and between-laboratory results were tested. In India, the sensitivities of all the RDTs ranged between 94.7 and 100.0%, with no significant differences between whole blood and serum. The specificities ranged between 92.4 and 100.0%, except for the specificity of the Onsite Leishmania Ab RevB kit, which was lower (33.6 to 42.0%). No differences in specificities were observed for blood and serum. In Nepal, the sensitivities of all the test kits, for whole-blood as well as serum samples, ranged between 96.3 and 100.0%, and the specificities ranged between 90.1 and 96.1%, again with the exception of that of the Onsite Leishmania Ab RevB test, which was markedly lower (48.7 to 49.3%). The diagnostic accuracies of all the tests, except for one brand, were excellent for the whole-blood and serum samples. We conclude that whole blood is an adequate alternative for serum in RDTs for VL, with sensitivities and specificities comparable to those obtained in serum samples, provided that the test kit is of overall good quality.

  9. Racial Differences in Serum Adipokine and Insulin Levels in a Matched Osteoarthritis Sample: A Pilot Study

    Directory of Open Access Journals (Sweden)

    Rajiv Gandhi

    2016-01-01

    Full Text Available Background. In an attempt to correlate biomarkers with disease, serum-based biomarkers often are compared between individuals with osteoarthritis (OA and control subjects. However, variable results have been reported. Some studies have suggested an association between certain adipokines and insulin and OA. We know that there are racial differences in OA prevalence and incidence, and from general population-based studies, those of Asian race consistently demonstrate a unique adipokine/insulin serum concentration profile as compared to Caucasians. Whether similar racial differences exist within OA samples is unknown and may have implications for selecting appropriate controls in comparative studies. Methods. Serum levels of adipokines, leptin, and adiponectin, along with insulin, were determined by ELISA in patients scheduled for total hip or knee replacement surgery for OA. Fifteen Asian patients were matched 1 : 1 on age (±2 years, gender, body mass index (±1.5 kg/m2, and surgical joint with Caucasian patients. Differences in serum concentrations were tested using paired t-tests. Results. Serum leptin and insulin levels were significantly higher in Asians compared to Caucasians (p<0.05. While serum adiponectin levels were lower among Asians, the difference did not reach statistical significance (p=0.12. Conclusion. Findings from this work suggest that when studying serum biomarker concentrations in OA versus controls, race may be an important factor to consider. Our findings warrant confirmation in larger studies.

  10. Use of an immunoaffinity column for tetrachlorodibenzo-p-dioxin serum sample cleanup.

    Science.gov (United States)

    Shelver, W L; Larsen, G L; Huwe, J K

    1998-02-13

    Covalently linking 1-amino-3,7,8-trichlorodibenzo-p-dioxin with either keyhole limpet hemocyanin (KLH) or bovine serum albumin (BSA) provided antigens that generated antibodies in chickens. Competitive ELISA analysis demonstrated that the antibodies isolated from egg yolk (IgY) bound with 1,3,7,8-tetrachlorodibenzo-p-dioxin (1,3,7,8-TCDD). The antibodies were linked to CNBr-Sepharose to generate an immunoaffinity column. Radiolabeled 1,3,7,8-TCDD in a 0.05% Tween 20 solution was retained by the column and could be eluted by increasing the Tween 20 concentration. The binding efficiency for 10.7 ng per ml gel matrix ranged from 85 to 97%. Immunoaffinity columns generated by this method did not effectively bind 14C-1,3,7,8-TCDD from serum samples. Diluting the serum 1:20 with 0.05% Tween 20 increased the binding efficiency. Alternately, ethanol-hexane extraction followed by solid phase extraction on a carbon column using a fat removal protocol also provided an appropriate preaffinity column cleanup for serum samples. After this preaffinity column cleanup, spiked serum samples applied to the immunoaffinity column showed binding efficiencies of over 90%.

  11. Serial Sampling of Serum Protein Biomarkers for Monitoring Human Traumatic Brain Injury Dynamics: A Systematic Review

    Directory of Open Access Journals (Sweden)

    Eric Peter Thelin

    2017-07-01

    Full Text Available BackgroundThe proteins S100B, neuron-specific enolase (NSE, glial fibrillary acidic protein (GFAP, ubiquitin carboxy-terminal hydrolase L1 (UCH-L1, and neurofilament light (NF-L have been serially sampled in serum of patients suffering from traumatic brain injury (TBI in order to assess injury severity and tissue fate. We review the current literature of serum level dynamics of these proteins following TBI and used the term “effective half-life” (t1/2 in order to describe the “fall” rate in serum.Materials and methodsThrough searches on EMBASE, Medline, and Scopus, we looked for articles where these proteins had been serially sampled in serum in human TBI. We excluded animal studies, studies with only one presented sample and studies without neuroradiological examinations.ResultsFollowing screening (10,389 papers, n = 122 papers were included. The proteins S100B (n = 66 and NSE (n = 27 were the two most frequent biomarkers that were serially sampled. For S100B in severe TBI, a majority of studies indicate a t1/2 of about 24 h, even if very early sampling in these patients reveals rapid decreases (1–2 h though possibly of non-cerebral origin. In contrast, the t1/2 for NSE is comparably longer, ranging from 48 to 72 h in severe TBI cases. The protein GFAP (n = 18 appears to have t1/2 of about 24–48 h in severe TBI. The protein UCH-L1 (n = 9 presents a t1/2 around 7 h in mild TBI and about 10 h in severe. Frequent sampling of these proteins revealed different trajectories with persisting high serum levels, or secondary peaks, in patients with unfavorable outcome or in patients developing secondary detrimental events. Finally, NF-L (n = 2 only increased in the few studies available, suggesting a serum availability of >10 days. To date, automated assays are available for S100B and NSE making them faster and more practical to use.ConclusionSerial sampling of brain-specific proteins in serum reveals

  12. Single versus duplicate blood samples in ACTH stimulated adrenal vein sampling

    NARCIS (Netherlands)

    Dekkers, T.; Arntz, M.; Wilt, G.J. van der; Schultze Kool, L.J.; Sweep, F.C.; Hermus, A.R.M.M.; Lenders, J.W.M.; Deinum, J.

    2013-01-01

    BACKGROUND: Adrenal vein sampling (AVS) is the preferred test for subtyping primary aldosteronism. However, the procedure is technically demanding and costly. In AVS it is common practice to take duplicate blood samples at each location. In this paper we explore whether a single sample procedure

  13. Benefits and Limits of Egg Yolk vs. Serum Samples for Avian Influenza Virus Serosurveillance.

    Science.gov (United States)

    Abdelwhab, E M; Grund, Christian; Aly, Mona M; Beer, Martin; Harder, Timm C; Hafez, Hafez M

    2016-06-01

    Serologic tests are a valuable tool for retrospective surveillance of avian influenza viruses (AIV) and monitoring of postvaccination host immune response. Yet collection of serum samples, particularly in adult breeder chickens, is laborious, intrusive to birds, and may pose a serious risk to the biosecurity of a flock. In this study we compared the level of AIV-specific antibody titers in eggs and serum samples obtained from broiler breeder chickens vaccinated at 6, 12, and 18 wk of age with H5N2-inactivated vaccine. Nucleocapsid protein-specific ELISA and hemagglutination inhibition test (HI) against homologous as well as heterologous antigens were used. The eggs and sera were collected at 22, 30, 45, and 50 wk of age (i.e., 4, 12, 27, and 32 wk after the third and final immunization, respectively). Using ELISA, the number of positive egg yolk samples decreased over time after vaccination, from 97% to 47%, while the seropositivity rate of serum samples was 97%-100% during the whole investigation period. No antibody titers were detected in egg white. By HI, antibody titers in serum samples were higher than in egg yolk samples. Compared to the homologous H5N2 antigen, significantly lower HI titers were obtained by using a heterologous H5N1 virus of clade 2.2.1.2. In addition, no HI titers were detected in egg yolk and/or serum samples tested against the antigen of an Egyptian H5N1 antigenic drift variant of clade 2.2.1.1. This study indicates that egg yolk may be used to monitor the postvaccination immune status of broiler breeder chickens and retrospective serosurveillance-by HI when a matching antigen is available as well as by ELISA-particularly for up to 12 wk postvaccination.

  14. Predictors of Serum 25-Hydroxyvitamin D Concentrations among a Sample of Egyptian Schoolchildren

    Directory of Open Access Journals (Sweden)

    Mones M. Abu Shady

    2016-01-01

    Full Text Available Objective. To assess the level of 25-hydroxyvitamin D status among a sample of Egyptian schoolchildren and to evaluate predictors of deficiency and insufficiency. Subjects and Methods. A cross-sectional study comprising 200 prepubescent schoolchildren aged from 9 to 11 years was performed. A questionnaire including frequency of midday sun exposure, milk intake, physical activity, and level of maternal education was taken. Body mass index (BMI was calculated; serum 25-hydroxyvitamin D [25(OHD], serum calcium, phosphorus, and parathyroid hormone were measured. Results. Vitamin D deficiency [serum 25(OHD < 20 ng/mL] was detected in 11.5% of subjects while its insufficiency (serum 25(OHD is between 20 and 29.9 ng/mL was detected in 15%. Results revealed that obesity, low physical activity, low sun exposure, and low maternal education level are significant predictors of insufficiency, though female gender, low maternal education level, and low milk intake are significant predictors of deficiency. Lower serum phosphorus and higher serum parathyroid hormone were significantly associated with both deficiency and insufficiency (p<0.05. Conclusion. Vitamin D deficiency and insufficiency are common among schoolchildren in Egypt. Food fortification, vitamin D supplementation, and increasing maternal awareness about the importance of physical activity and exposure of their children to ultraviolet light may help to overcome this problem.

  15. Stability of anti-immunotherapeutic antibodies in frozen human serum samples.

    Science.gov (United States)

    Michaut, Lydia; Laurent, Nathalie; Kentsch, Kerstin; Spindeldreher, Sebastian; Deckert-Salva, Fabienne

    2014-05-01

    To generate exhaustive data on the stability of human anti-immunotherapeutic antibodies. Samples collected from over 100 different subjects at various timepoints were analyzed shortly after serum collection using specific ELISAs and re-analyzed after long-term storage or multiple cycles of freeze-thaw. The general acceptance criteria for incurred sample reanalysis for ligand-binding assays were applied, as well as alternative stricter acceptance criteria promoted by various white papers. Anti-immunotherapeutic antibodies are stable in undiluted serum samples stored at -80°C for at least 3.5 years and 3-12 freeze-thaw cycles. Samples were selected to cover the heterogeneity of the polyclonal human immune response, therefore this stability data can be extended to all anti-vaccine and anti-drug antibodies.

  16. a comparison between the use of single and composite samples

    African Journals Online (AJOL)

    Dr F Neser

    South African Society for Animal Science. 44. A comparison between single and composite milk samples for the genetic evaluation of milk composition in dairy cattle. R. van Dyk1, F.W.C. Neser1# & F.H. Kanfer2. 1 Department of Animal Science, University of the Free State, PO Box 339, Bloemfontein 9300, South Africa.

  17. Quantitative profiling of serum samples using TMT protein labelling, fractionation and LC-MS/MS.

    Science.gov (United States)

    Sinclair, John; Timms, John F

    2011-08-01

    Blood-borne biomarkers are urgently required for the early detection, accurate diagnosis and prognosis of disease. Additionally, improved methods of profiling serum and plasma proteins for biomarker discovery efforts are needed. Herein, we report a quantitative method based on amino-group labelling of serum proteins (rather than peptides) with isobaric tandem mass tags (TMT) and incorporating immune-based depletion, gel-based and strong anion exchange separation of proteins prior to differential endoproteinase treatment and liquid chromatography tandem mass spectrometry. We report a generally higher level of quantitative coverage of the serum proteome compared to other peptide-based isobaric tagging approaches and show the potential of the method by applying it to a set of unique samples that pre-date the diagnosis of pancreatic cancer. Copyright © 2011 Elsevier Inc. All rights reserved.

  18. Oxytetracycline hydrochloride in the horse: serum, synovial, peritoneal and urine concentrations after single dose intravenous administration.

    Science.gov (United States)

    Brown, M P; Stover, S M; Kelly, R H; Farver, T B; Knight, H D

    1981-03-01

    Six adult mares were given a single intravenous injection of oxytetracycline HCl (50 mg/ml) at a dosage of 5 mg/kg. Serum, synovial fluid, peritoneal fluid, and urine oxytetracycline concentrations were measured serially over a 48-h period. The highest measured serum oxytetracycline concentration was 8.01 mcg/ml at 1/2 h. Oxytetracycline was detected in synovial fluid and peritoneal fluid, which obtained mean peak oxytetracycline concentrations of 4.43 mcg/ml and 4.20 mcg/ml, at 1/2 h and 1 h, respectively. These concentrations steadily declined in parallel with serum concentrations and were not measurable at 48 h. Urine oxytetracycline concentration was relatively high, with a peak concentration of 1565.2 mcg/ml at 1/2 h after drug administration.

  19. Genomic Sequencing of Single Microbial Cells from Environmental Samples

    Energy Technology Data Exchange (ETDEWEB)

    Ishoey, Thomas; Woyke, Tanja; Stepanauskas, Ramunas; Novotny, Mark; Lasken, Roger S.

    2008-02-01

    Recently developed techniques allow genomic DNA sequencing from single microbial cells [Lasken RS: Single-cell genomic sequencing using multiple displacement amplification, Curr Opin Microbiol 2007, 10:510-516]. Here, we focus on research strategies for putting these methods into practice in the laboratory setting. An immediate consequence of single-cell sequencing is that it provides an alternative to culturing organisms as a prerequisite for genomic sequencing. The microgram amounts of DNA required as template are amplified from a single bacterium by a method called multiple displacement amplification (MDA) avoiding the need to grow cells. The ability to sequence DNA from individual cells will likely have an immense impact on microbiology considering the vast numbers of novel organisms, which have been inaccessible unless culture-independent methods could be used. However, special approaches have been necessary to work with amplified DNA. MDA may not recover the entire genome from the single copy present in most bacteria. Also, some sequence rearrangements can occur during the DNA amplification reaction. Over the past two years many research groups have begun to use MDA, and some practical approaches to single-cell sequencing have been developed. We review the consensus that is emerging on optimum methods, reliability of amplified template, and the proper interpretation of 'composite' genomes which result from the necessity of combining data from several single-cell MDA reactions in order to complete the assembly. Preferred laboratory methods are considered on the basis of experience at several large sequencing centers where >70% of genomes are now often recovered from single cells. Methods are reviewed for preparation of bacterial fractions from environmental samples, single-cell isolation, DNA amplification by MDA, and DNA sequencing.

  20. Improvement of precision for pipetting blood serum samples into a graphite furnace

    Science.gov (United States)

    Bohrer, D.; do Nascimento, P. C.; Binotto, R.; Borges da Costa, J. A. T.; Szlachta, T.

    2002-12-01

    Graphite furnace atomic absorption spectrometry is a well-established technique for trace metal determination in blood and serum samples. For this kind of samples, a R.S.D. of up to 10% is considered acceptable, especially for those elements, the concentrations of which do not allow high dilution. Among the reasons that contribute to an increase of the S.D. is the retention of proteins (and analyte) in the sample dispenser capillary, because proteins might be adsorbed on polymeric surfaces. In the present work, the interaction protein/polymer was studied, considering the amount of protein that could be retained by the capillary, the influence of sample dilution, time of contact and the possible co-adsorption of metals. Serum proteins were retained in the capillary, depending on the material (Tygon>silicone rubber>poly(tetrafluorethylene)); dilution did not prevent the adsorption, and only 30 s of contact were enough for the adsorption to occur. Using a column filled with PTFE powder (60 mesh), it was possible to observe that metals were co-adsorbed to a large extent. Water, diluted nitric acid or aqueous solutions of Triton X-100 were not able to promote the complete desorption of the proteins retained by the polymeric materials. Total elution was achieved with methanol, and its use as rinse solution decreased the R.S.D. ( n=10) for aluminium, manganese and chromium determination in serum to <10%.

  1. Evaluation of Sample Handling Effects on Serum Vitamin E and Cholesterol Concentrations in Alpacas

    Directory of Open Access Journals (Sweden)

    Andrea S. Lear

    2014-01-01

    Full Text Available Clinical cases of vitamin E deficiencies have been diagnosed in camelids and may indicate that these species are more sensitive to inadequate vitamin E in hay-based diets compared to other ruminant and equine species. In bovine, cholesterol has been reported to affect vitamin E concentrations. In order to evaluate vitamin E deficiencies in camelids, the effects of collection and storage of the blood samples prior to processing were necessary. Reports vary as to factors affecting vitamin E and cholesterol in blood samples, and diagnostic laboratories vary in instructions regarding sample handling. Blood was collected from healthy alpacas and processed under conditions including exposure to fluorescent light, serum and red blood cell contact, tube stopper contact, temperature, and hemolysis. Serum vitamin E and cholesterol concentrations were then measured. Statistical analyses found that the vitamin E concentrations decreased with prolonged contact with the tube stopper and with increasing hemolysis. Vitamin E concentration variations were seen with other factors but were not significant. Time prior to serum separation and individual animal variation was found to alter cholesterol concentrations within the sample, yet this finding was clinically unremarkable. No correlation was seen between vitamin E and cholesterol concentration, possibly due to lack of variation of cholesterol.

  2. Cefodizime in serum and skin blister fluid after single intravenous and intramuscular doses in healthy volunteers.

    OpenAIRE

    Korting, H C; Schäfer-Korting, M; Maass, L; Klesel, N; Mutschler, E

    1987-01-01

    In gonorrhea therapy, cephalosporins are conventionally administered by intramuscular (i.m.) injection, which rather frequently leads to local side effects. To investigate whether the well-tolerated intravenous (i.v.) injection of cephalosporins may be of comparable gonocidal effect, levels of cefodizime, a new broad-spectrum cephalosporin, in serum and tissue fluid (suction blister and cantharides blister fluid) were determined in six healthy men. Single doses of 1 g of cefodizime were injec...

  3. Serum chromium levels sampled with steel needle versus plastic IV cannula. Does method matter?

    DEFF Research Database (Denmark)

    Penny, Jeannette Ø; Overgaard, Søren

    2010-01-01

    PURPOSE: Modern metal-on-metal (MoM) joint articulations releases metal ions to the body. Research tries to establish how much this elevates metal ion levels and whether it causes adverse effects. The steel needle that samples the blood may introduce additional chromium to the sample thereby...... causing bias. This study aimed to test that theory. METHODS: We compared serum chromium values for two sampling methods, steel needle and IV plastic cannula, as well as sampling sequence in 16 healthy volunteers. RESULTS: We found statistically significant chromium contamination from the steel needle...... significant. CONCLUSION: The chromium contamination from the steel needle is low, and sampling method matters little in MoM populations. If using steel needles we suggest discarding the first sample....

  4. Quality assesment for the analysis of PCDDs/PCDFs in individual human serum samples

    Energy Technology Data Exchange (ETDEWEB)

    Perez, F. [IIQAB-CSIC, Barcelona (Spain). Dept. of Ecotechnologies, Lab. of Dioxins; Abad, E.; Llerena, J.J.; Caixach, J.; Rivera, J.

    2004-09-15

    The aim of this work was to optimise a relevant methodology for the ultratrace analysis of PCDDs/PCDFs in individual human serum samples. In order to carry out the study, different strategies including the elaboration of quality control samples, parallel sample analysis, control blanks and a number of quality assurance measures were implemented as analytical current practices. Some of the main drawbacks in the analysis of PCDDs/PCDFs in these kind of samples come from two conflicting aspects: the small sample size and the low levels expected to be found. Taking this into account, an unavoidable compromise between the sample amount and the minimum analytical requirements, mainly the detection limit (LOD), is mandatory. To reach this goal C{sub 18} solid phase extraction was used to remove the analytes from the matrix. Clean up was performed by solid-liquid adsorption chromatography using a variety of adsorbents. Instrumental analysis was achieved by high-resolution gas chromatography coupled to high-resolution mass spectrometry (HRGC/HRMS). Finally, the optimised methodology was applied to evaluate the potential impact in general population living in the surroundings of an obsolete municipal waste incinerator plant (MWI). Thus, more than 400 individuals serum samples potentially exposed to the emission of the incinerator and people not exposed were considered in this study.

  5. Determination of Se and Zn elements in blood serum samples by neutron activation analysis

    International Nuclear Information System (INIS)

    Indah Kusmartini; Rukruk Rukayah; Woro Yatu NS; Muhayatun; Rochestry Sofyan

    2010-01-01

    Se and Zn are essential elements being required for activity several enzyme systems in human metabolism. The elements in blood serum as well as to obtain information regarding the health status of individuals, so that important to investigated. Commonly Se and Zn elements in blood serum are low in concentration with limited samples weight, therefore high sensitive and accurate analysis method like NAA are needed. This study aims to determine the content of the elements Se and Zn in blood serum of employee using NAA technique. The samples were freeze dried then irradiated at rabbit system facility of G.A. Siwabessy Serpong reactor with neutron flux ~10 13 n.cm -2 .s -1 for 2 hours. Then samples were counted for 50000 s by HPGe spectrometer gamma and analyzed by software GENIE 2000. Method validation was also applied by analyzing the Reference Material IAEA Animal Blood RM A-13. The range concentration of elements Se and Zn were 0.06-0.17 μg/mL and 0.56-1.37 μg/mL with overall mean 0.10 ± 0.01 μg/mL and 0.97 ± 0.07 μg/mL. The value showed that appropriate with last researcher and another country. (author)

  6. The effect of delayed transportation of blood samples on serum bilirubin values in neonates.

    Science.gov (United States)

    Saththasivam, Poovendran; Voralu, Kirtanaa; Ramli, Noraida; Mustapha, Mohd Rafi; Omar, Julia; Van Rostenberghe, Hans

    2010-07-01

    Delays in transporting blood samples may cause inaccurate results. Samples may be exposed to light or heat during delays, resulting in the degradation of analytes, for example, bilirubin. This study was done to determine the effect of delays in the transportation of blood samples on serum bilirubin test results. Samples taken from neonates admitted to a tertiary hospital with jaundice were included in the study. The samples were collected through venipuncture in 3 labelled containers. The first container was sent immediately to the laboratory, while the second and third containers were sent after being kept in the ward for 1 and 3 hours, respectively. Bilirubin values were measured colourimetrically at a wavelength of 578 nm using a Roche Hitachi 912 Chemistry Analyser upon arrival in the laboratory. A total of 36 serum samples were studied. The mean of the indirect bilirubin measurements for 0-, 1-, and 3-hour samples were 174 (SD 68.65), 186.97 (SD 60.47), and 184.56 (SD 66.93), respectively. There was a significant difference in the mean indirect bilirubin measurement of 1-hour samples (P = 0.047, 95% CI -24.66 to -1.18) and 3-hour samples (P = 0.045, 95% CI -19.77 to -0.23) compared with 0-hour samples. There were no significant differences observed in either the mean total bilirubin or the mean direct bilirubin measurements of different time intervals. This study confirms that delays in the transportation of blood samples influence the bilirubin test results.

  7. Chromogranin A as Serum Marker for Gastroenteropancreatic Neuroendocrine Tumors: A Single Center Experience and Literature Review

    Energy Technology Data Exchange (ETDEWEB)

    Nölting, Svenja; Kuttner, Axel [Department of Internal Medicine II, Campus Grosshadern, University-Hospital of the Ludwig-Maximilians-University of Munich, Munich 81377 (Germany); Lauseker, Michael [Institute of Medical Informatics, Biometry and Epidemiology, University of Munich, Munich 81377 (Germany); Vogeser, Michael [Department of Clinical Chemistry, Campus Grosshadern, University-Hospital of the Ludwig-Maximilian-University of Munich, Munich 81377 (Germany); Haug, Alexander [Clinic of Nuclear Medicine, Campus Grosshadern, University-Hospital of the Ludwig-Maximilian-University of Munich, Munich 81377 (Germany); Herrmann, Karin A. [Institute of Radiology, Campus Grosshadern, University-Hospital of the Ludwig-Maximilian-University of Munich, Munich 81377 (Germany); Hoffmann, Johannes N. [Department of Surgery, Campus Grosshadern, University-Hospital of the Ludwig-Maximilians-University of Munich, Munich 81377 (Germany); Spitzweg, Christine; Göke, Burkhard; Auernhammer, Christoph J., E-mail: christoph.auernhammer@med.uni-muenchen.de [Department of Internal Medicine II, Campus Grosshadern, University-Hospital of the Ludwig-Maximilians-University of Munich, Munich 81377 (Germany)

    2012-02-15

    The aim of this study was to assess the clinical sensitivities of the tumor markers chromogranin A (CgA), urinary 5-hydroxyindoleacetic acid (5-HIAA) and alkaline phosphatase (AP) in neuroendocrine tumors (NETs) of the GastroEnteroPancreatic-(GEP-) system depending on tumor primary location and metastatic spread. In a retrospective single-center series, sensitivities were evaluated in serum samples from 110 patients with midgut (n = 62) and pancreatic (n = 48) NETs. CgA levels were analyzed by a commercially-available immunoradiometric assay (CIS-bio) during routine follow-up in the years 2000–2009. CgA showed a higher sensitivity for midgut (68%) than pancreatic (54%) NETs. A higher CgA sensitivity and significantly higher median CgA values were found in patients with liver metastases than in those without, and in patients with hepatic and additionally extra-hepatic metastases than in those with hepatic and nodal metastases alone, respectively. We found an overall sensitivity for elevated 5HIAA excretion of 69% for midgut NETs and a significant correlation between median CgA and 5-HIAA values. The sensitivity of AP and the correlations of AP/CgA-data-pairs were low in both midgut and pancreatic NETs, although highest for metastatic pancreatic NETs. The sensitivity of CgA measurement depends on the NET primary location and spread of disease. 5-HIAA and CgA showed comparable sensitivity in midgut NETs, while AP does not seem to be useful as a tumor marker in GEP-NETs.

  8. Retrospective analysis of dengue specific IgM reactive serum samples

    OpenAIRE

    Bhattacharya, Nemai; Bandyopadhyay, Bhaswati; Bhattacharjee, Indranil; Mukherjee, Hiranmoy; Talukdar, Srabani; Mondal, Ruby; Pramanick, Netai; Chandra, Goutam; Hati, Amiya K.

    2013-01-01

    Objective: To conduct a retrospective analysis of dengue cases in Kolkata, on the basis of presence of anti-dengue IgM in their sera and presence or absence of anti-dengue IgG and dengue specific Non structural 1 (NS1) antigen in each of the serum sample. Methods: Sample was tested quantitatively employing ELISA technique, using Biorad test kits, with a view to get a more comprehensive picture of dengue in an urban endemic area and also to evaluate individual cases. Results: Th...

  9. An attempt to validate serum and plasma as sample matrices for analyses of polychlorobiphenylols

    Energy Technology Data Exchange (ETDEWEB)

    Weiss, J.; Bergman, Aa. [Stockholm Univ. (Sweden). Dept. of Environmental Chemistry; Bignert, A. [Museum of Natural History (Sweden)

    2004-09-15

    Polychlorinated biphenyls (PCBs) form hydroxylated metabolites (OH-PCBs), as reported both from wildlife and from experimental animal studies already in the early 1970s'. However, the interest increased in OH-PCBs from the mid 1990s' depending on the discovery that some OHPCB congeners are strongly retained in the blood of birds, fish and mammals, including humans. The interest is linked to the fact that OH-PCBs is strongly, but reversibly, bound to the blood protein transthyretin (TTR). It is reasonable to believe that the strong TTR binding may have toxicological impact, probably related to endocrine type effects. Importantly, OH-PCBs are present in blood at far higher concentrations than in any other compartment in the body, which is dependent on the physico-chemical characteristics of the phenols. Analyses of OH-PCBs have thus been concentrated to whole blood, plasma or serum. Still there is no comparison between the three sample types even though it is clear that whole blood is not optimal due to the large proportion of haemoglobin in the sample that make the clean up more difficult than if plasma or serum is selected for analysis. In the present study we have addressed two questions: First we have looked at any potential differences in the analytical results of OH-PCBs when using serum and plasma for extraction and clean up; Second, the serum and plasma applied in the validation has been unfrozen, frozen (at -20 C) for two months and frozen for twenty months, respectively.

  10. The accuracy of single serum progesterone measurement in the diagnosis of ectopic pregnancy: a meta-analysis

    NARCIS (Netherlands)

    Mol, B. W.; Lijmer, J. G.; Ankum, W. M.; van der Veen, F.; Bossuyt, P. M.

    1998-01-01

    Serum progesterone measurement has been advocated as a diagnostic tool in the non-invasive diagnosis of ectopic pregnancy. To assess the accuracy of a single serum progesterone measurement in the diagnosis of ectopic pregnancy, a meta-analysis was performed incorporating 26 studies evaluating the

  11. Application of PCR in serum samples for diagnosis of paracoccidioidomycosis in the southern Bahia-Brazil.

    Directory of Open Access Journals (Sweden)

    Lucas Dias

    Full Text Available Paracoccidioidomycosis (PCM cannot always be diagnosed by conventional means such as direct examination of histopathology or clinical samples, and serological methods, used as an alternative, still have many cases of cross-reactivity. In this scenario, molecular techniques seem to arise as a rapid approach, specific and direct that could be used in the diagnosis of this mycosis. In this study we analyzed 76 serum samples from patients in southern Bahia suspected of having paracoccidioidomycosis using a conventional PCR with primers for the ITS1 ribosomal DNA of P. brasiliensis. Of these 76 patients, 5 were positive for PCM by double immunodiffusion and/or direct examination and histopathology. To test specificity of PCR, we used human DNA and three isolates of P. lutzii (1578, 01 and ED01. Additionally, we analyzed by serial dilutions of DNA the limit of detection of the assay. The test of PCR proved specific, as only a 144 bp fragment of the three isolates of P. lutzii and no human DNA was amplified. Detection limit was 1.1 pg/µL of DNA. Despite the high detection limit and specificity of PCR none of the 76 serum samples were found positive by PCR, but a biopsy specimen obtained from one of the patients with PCM was positive. These results, albeit limited, show that PCR is not effective in detecting DNA of P. brasiliensis or P. lutzii in serum, but could perhaps be used with other types of clinical samples, especially in those instances in which conventional methods fail.

  12. A Single Platinum Microelectrode for Identifying Soft Drink Samples

    Directory of Open Access Journals (Sweden)

    Lígia Bueno

    2012-01-01

    Full Text Available Cyclic voltammograms recorded with a single platinum microelectrode were used along with a non-supervised pattern recognition, namely, Principal Component Analysis, to conduct a qualitative analysis of sixteen different brands of carbonated soft drinks (Kuat, Soda Antarctica, H2OH!, Sprite 2.0, Guarana Antarctica, Guarana Antarctica Zero, Coca-Cola, Coca-Cola Zero, Coca-Cola Plus, Pepsi, Pepsi Light, Pepsi Twist, Pepsi Twist Light, Pepsi Twist 3, Schin Cola, and Classic Dillar’s. In this analysis, soft drink samples were not subjected to pre-treatment. Good differentiation among all the analysed soft drinks was achieved using the voltammetric data. An analysis of the loading plots shows that the potentials of −0.65 V, −0.4 V, 0.4 V, and 0.750 V facilitated the discrimination process. The electrochemical processes related to this potential are the reduction of hydrogen ions and inhibition of the platinum oxidation by the caffeine adsorption on the electrode surface. Additionally, the single platinum microelectrode was useful for the quality control of the soft drink samples, as it helped to identify the time at which the beverage was opened.

  13. Specific Antibodies Reacting with SV40 Large T Antigen Mimotopes in Serum Samples of Healthy Subjects.

    Directory of Open Access Journals (Sweden)

    Mauro Tognon

    Full Text Available Simian Virus 40, experimentally assayed in vitro in different animal and human cells and in vivo in rodents, was classified as a small DNA tumor virus. In previous studies, many groups identified Simian Virus 40 sequences in healthy individuals and cancer patients using PCR techniques, whereas others failed to detect the viral sequences in human specimens. These conflicting results prompted us to develop a novel indirect ELISA with synthetic peptides, mimicking Simian Virus 40 capsid viral protein antigens, named mimotopes. This immunologic assay allowed us to investigate the presence of serum antibodies against Simian Virus 40 and to verify whether Simian Virus 40 is circulating in humans. In this investigation two mimotopes from Simian Virus 40 large T antigen, the viral replication protein and oncoprotein, were employed to analyze for specific reactions to human sera antibodies. This indirect ELISA with synthetic peptides from Simian Virus 40 large T antigen was used to assay a new collection of serum samples from healthy subjects. This novel assay revealed that serum antibodies against Simian Virus 40 large T antigen mimotopes are detectable, at low titer, in healthy subjects aged from 18-65 years old. The overall prevalence of reactivity with the two Simian Virus 40 large T antigen peptides was 20%. This new ELISA with two mimotopes of the early viral regions is able to detect in a specific manner Simian Virus 40 large T antigen-antibody responses.

  14. Specific IgA and IgG antibodies in paired serum and breast milk samples in human strongyloidiasis.

    Science.gov (United States)

    Mota-Ferreira, Daniela M L; Gonçalves-Pires, Maria do Rosário F; Júnior, Alvaro Ferreira; Sopelete, Mônica C; Abdallah, Vânia O S; Costa-Cruz, Julia M

    2009-02-01

    Strongyloidiasis, caused by the nematode Strongyloides stercoralis, is one of the major worldwide parasitic infections in humans. Breastfeeding may offer a potential protection against this infection. Feces, serum and milk samples were obtained from 90 lactating women from Clinical Hospital of Universidade Federal de Uberlândia, Brazil. The fecal samples were collected for parasitological diagnosis and the serum and milk samples were examined for specific S. stercoralis IgA and IgG antibodies using the indirect fluorescent antibody test (IFAT) and enzyme-linked immunosorbent assay (ELISA). Fecal examination showed that the rate of prevalence of S. stercoralis infection in the lactating women was 4.4%. IFAT manifested a 16.7% positivity rate for specific IgA antibody in serum and a 28.9% rate in milk samples; specific IgG was 41.1% in serum and 25.5% in milk samples. According to ELISA the positivity rate for specific IgA antibody was 21.1% in serum and 42.2% in milk samples; specific IgG was 40% in serum and 18.9% in milk samples. In serum samples, these immunological tests showed a concurrence of 91.1% and 94.4%, respectively, in detecting specific IgA and IgG antibodies. In milk samples, they showed a concurrence of 70% and 78.9%, respectively, in detecting specific IgA and IgG antibodies. There was a statistically significant difference between concordant and discordant results of immunological tests (Pantibodies in serum and in milk samples reconfirming prior studies that the serological method is a complement to the direct diagnosis of the parasite, and suggesting that immunological methods using milk samples can also be helpful. Furthermore, in endemic areas, infants may acquire antibodies to S. stercoralis from breast milk, possibly, contributing to the enhancement of specific mucosal immunity against this parasite.

  15. Simpler and Faster Spectrophotometric Determination of Diclofenac Sodium in Tablets, Serum and Urine Samples

    Directory of Open Access Journals (Sweden)

    Abdul Rauf Khaskheli

    2009-12-01

    Full Text Available This work describes a simple, sensitive, rapid and economical analytical procedure for direct spectrophotometric evaluation of diclofenac sodium (DS using aqueous medium without using a chemical reagent. Parameters like time, temperature, acidic and basic conditions and interference by analgesic drugs were studied for a 5µg ml-1 solution of DS at 276 nm. Under optimized parameters, a linear working range of 0.1–30 g ml-1 with regression coefficient of 0.9998 and lower detection limit of 0.01 g ml-1 was obtained. The method was applied for DS contents in tablets, serum and urine samples.

  16. Single Molecule Arrays for ultra-sensitive detection of rat cytokines in serum.

    Science.gov (United States)

    Cohen, Limor; Xie, Liangxia; Xylas, Mark E; Walt, David R

    2018-01-01

    Rats are used as animal models for many human diseases. Cytokines can serve as biomarkers indicative of these diseases or disease states. Techniques for measuring cytokine expression levels often do not provide the sensitivity needed to measure these biomarkers in biological fluids because the concentrations of many cytokines are below the detection limits of conventional methods. In this paper, we present ultra-sensitive digital immunoassays using Single Molecule Arrays (Simoa) for seven rat cytokines: TNF-α, IL-10, IL-17F, GM-CSF, IFN-γ, IL-4, and IL-1α. These ultra-sensitive immunoassays have limits of detection (LODs) in the femtomolar range and provide the ability to measure rat cytokines in serum below the LODs of conventional immunoassays. We also measured these cytokines in healthy rat serum to obtain baseline levels. The ability to measure cytokines present at low concentrations in rat serum will facilitate future studies of disease using rats as animal models. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Human serum albumin adsorption on TiO2 from single protein solutions and from plasma.

    Science.gov (United States)

    Sousa, S R; Moradas-Ferreira, P; Saramago, B; Melo, L Viseu; Barbosa, M A

    2004-10-26

    In the present work, the adsorption of human serum albumin (HSA) on commercially pure titanium with a titanium oxide layer formed in a H(2)O(2) solution (TiO(2) cp) and on TiO(2) sputtered on Si (TiO(2) sp) was analyzed. Adsorption isotherms, kinetic studies, and work of adhesion determinations were carried out. HSA exchangeability was also evaluated. Surface characterization was performed by atomic force microscopy (AFM), X-ray photoelectron spectroscopy (XPS), and wettability studies. The two TiO(2) surfaces have very distinct roughnesses, the TiO(2) sp having a mean R(a) value 14 times smaller than the one of TiO(2) cp. XPS analysis revealed consistent peaks representative of TiO(2) on sputtered samples as well as on Ti cp substrate after 48 h of H(2)O(2) immersion. Nitrogen was observed as soon as protein was present, while sulfur, present in disulfide bonds in HSA, was observed for concentrations of protein higher than 0.30 mg/mL. The work of adhesion was determined from contact angle measurements. As expected from the surface free energy values, the work of adhesion of HSA solution is higher for the TiO(2) cp substrate, the more hydrophilic one, and lower for the TiO(2) sp substrate, the more hydrophobic one. The work of adhesion between plasma and the substrates assumed even higher values for the TiO(2) cp surface, indicating a greater interaction between the surface and the complex protein solutions. Adsorption studies by radiolabeling of albumin ((125)I-HSA) suggest that rapid HSA adsorption takes place on both surfaces, reaching a maximum value after approximately 60 min of incubation. For the higher HSA concentrations in solution, a multilayer coverage was observed on both substrates. After the adsorption step from single HSA solutions, the exchangeability of adsorbed HSA molecules by HSA in solution was evaluated. The HSA molecules adsorbed on TiO(2) sp seem to be more easily exchanged by HSA itself than those adsorbed on TiO(2) cp after 24 h. In

  18. A single sample GnRHa stimulation test in the diagnosis of precocious puberty

    Directory of Open Access Journals (Sweden)

    Yazdani Parvin

    2012-07-01

    Full Text Available Abstract Context Gonadotropin-releasing hormone (GnRH has been the standard test for diagnosing central precocious puberty. Because GnRH is no longer available, GnRH analogues (GnRHa are now used. Random LH concentration, measured by the third-generation immunochemiluminometric assay, is a useful screening tool for central precocious puberty. However, GnRHa stimulation test should be considered, when a basal LH measurement is inconclusive. However optimal sampling times for luteinizing hormone (LH have yet to be established. Purpose To determine the appropriate sampling time for LH post leuprolide challenge. Methods A retrospective analysis of multi-sample GnRHa stimulation tests performed in 155 children (aged 1–9 years referred for precocious puberty to Texas Children’s Hospital. After 20 mcg/kg of SQ leuprolide acetate, samples were obtained at 0, 1, 3, and 6 hours. Results Of 71 children with clinical evidence of central precocious puberty, fifty nine children had a peak LH >5 mIU/mL. 52 (88% of these responders had positive responses at 1 hour (95% CI is 80–96%, whereas all 59 children (100% had a peak LH response >5 mIU/mL at 3 hours (95% CI is 94-100%, P = 0.005. Conclusions A single serum LH sample collected 3 hours post GnRHa challenge is the optimal sample to establish the diagnosis of central precocious puberty.

  19. Comparison of parasite loads in serum and blood samples from patients in acute and chronic phases of Chagas disease.

    Science.gov (United States)

    Hernández, Carolina; Teherán, Aníbal; Flórez, Carolina; Ramírez, Juan David

    2018-04-17

    Molecular methods have been developed for the detection and quantification of Trypanosoma cruzi DNA in blood samples from patients with Chagas disease. However, aspects of sample processing necessary for quantitative real-time PCR (qPCR), such as the addition of guanidine hydrochloride to whole blood samples, may limit timely access to molecular diagnosis. We analysed 169 samples from serum and guanidine-EDTA blood (GEB) obtained from patients in acute and chronic phases of Chagas disease. We applied qPCR targeted to the satellite DNA region. Finally, we compared the parasite loads and cycle of threshold values of the qPCR. The results confirmed the usefulness of serum samples for the detection and quantification of parasite DNA in patients with Chagas disease, especially in the acute phase. However, the parasite loads detected in serum samples from patients in the chronic phase were lower than those detected in GEB samples. The epidemiological implications of the findings are herein discussed.

  20. Slurry sampling in serum blood for mercury determination by CV-AFS

    International Nuclear Information System (INIS)

    Aranda, Pedro R.; Gil, Raul A.; Moyano, Susana; De Vito, Irma; Martinez, Luis D.

    2009-01-01

    The heavy metal mercury (Hg) is a neurotoxin known to have a serious health impact even at relatively low concentrations. A slurry method was developed for the sensitive and precise determination of mercury in human serum blood samples by cold vapor generation coupled to atomic fluorescence spectrometry (CV-AFS). All variables related to the slurry formation were studied. The optimal hydrochloric concentration and tin(II) chloride concentration for CV generation were evaluated. Calibration within the range 0.1-10 μg L -1 Hg was performed with the standard addition method, and compared with an external calibration. Additionally, the reliability of the results obtained was evaluated by analyzing mercury in the same samples, but submitted to microwave-assisted digestion method. The limit of detection was calculated as 25 ng L -1 and the relative standard deviation was 3.9% at levels around of 0.4 μg L -1 Hg

  1. A Novel Genetic Group of Bovine Hepacivirus in Archival Serum Samples from Brazilian Cattle

    Directory of Open Access Journals (Sweden)

    Cláudio W. Canal

    2017-01-01

    Full Text Available Hepatitis C virus (HCV (genus Hepacivirus; family Flaviviridae is a major human pathogen causing persistent infection and hepatic injury. Recently, emerging HCV-like viruses were described infecting wild animals, such as bats and rodents, and domestic animals, including dogs, horses, and cattle. Using degenerate primers for detecting bovine pestiviruses in a 1996 survey three bovine serum samples showed a low identity with the genus Pestivirus of the Flaviviridae family. A virus could not be isolated in cell culture. The description of bovine hepaciviruses (BovHepV in 2015 allowed us to retrospectively identify the sequences as BovHepV, with a 88.9% nucleotide identity. In a reconstructed phylogenetic tree, the Brazilian BovHepV samples grouped within the bovine HCV-like cluster in a separated terminal node that was more closely related to the putative bovine Hepacivirus common ancestor than to bovine hepaciviruses detected in Europe and Africa.

  2. Evaluation of polymerase chain reaction for the detection of Paracoccidioides brasiliensis DNA on serum samples from patients with paracoccidioidomycosis

    Directory of Open Access Journals (Sweden)

    Cecília Eugenia Charbel

    2006-03-01

    Full Text Available The aim of this study was to demonstrate the DNA of Paracoccidioides brasiliensis in human serum samples of patients with paracoccidioidomycosis using the polymerase chain reaction (PCR. The diagnosis of paracoccidioidomycosis (PCM was defined by microscopic observation of the fungus on direct exam or histopathology, culture, and serological positivity. DNA from serum of 33 patients with PCM was extracted and submitted to nested-PCR using primers from the gp 43 gene. Only one sample was positive on nested-PCR. We conclude that the prevalence of fungemia in patients with different clinical forms of PCM is low, limiting the use of serum DNA detection as an alternative diagnostic tool.

  3. Study of Zn/Cu ratio and oligoelements in serum samples for cancer diagnosis

    International Nuclear Information System (INIS)

    Lue-Meru, M. P.; Jimenez, E.; Hernandez, E.; Rojas, A.; Greaves, E.

    2000-01-01

    The aim of this work was to study methods for cancer diagnosis based on trace element determination in serum blood samples. TXRF technique was selected for the analysis, due to its simultaneous and multi-elemental character, the very small amount of sample required and the high sensitivity. For the study, blood samples were collected from normal individuals (Blood donors and students), classified by age and sex in order to obtain reference normal values for the elements Zn, Cu, Fe, Mn, Se, and additionally, Ca and K. Samples from cancer patients before treatment and under treatment were collected at the oncological Service (BADAN-Lara), and were also classified by age and sex. The TXRF procedure used was developed in a previous work and involves the direct analysis and the use of Compton peak as Internal Standard. All the samples were analyzed by the routine clinical test (blood chemistry). Elemental concentrations and clinical data were processed with the statistical package Minitab-Windows, in order to establish the respective correlation. Concerning to elemental concentrations, significant differences were found in Zn/Cu ratio between normal individuals group and the cancer patients group. (author)

  4. Short term changes in melatonin and cortisol serum levels after a single administration of estrogen to menopausal women.

    Science.gov (United States)

    Kerdelhué, Bernard; Andrews, Mason C; Zhao, Yueqin; Scholler, Robert; Jones, Howard W

    2006-10-01

    It has been well-documented that serum melatonin levels are insensitive to estrous or menstrual ovarian steroid variations in the female rat or the human. However, a negative coupling has been already demonstrated between the nocturnal serum melatonin peak and serum E2 concentration during the late premenopausal period in the woman. The objection of the present study was designed to determine if diurnal serum melatonin values can be also lowered by a single administration of estrogen. We performed a detailed analysis of variations of serum estradiol, LH, FSH, melatonin and cortisol after one single I.M. injection of 2 mg of a conjugated estrogen, delestrogen (estradiol valerate) in 0.1 ml of oil. A 15 ml blood collection was done at 8:00 a.m. before the injection, and at 8:30 a.m., 9:00 a.m., 10:00 a.m., 12:00 noon, and 4:00 p.m. 17beta-estradiol, LH and FSH were determined by microparticle enzyme immunoassays kits. Melatonin determination was made using a RIA kit and cortisol was assayed by a RIA method. A significant rise in serum 17beta-estradiol was already seen by one hour after the injection of estradiol valerate. Then, an almost linear increase was observed up to at last eight hours after the injection of estradiol valerate. A significant decrease in serum LH was not seen before four hours after the injection of estradiol valerate. Overall, there was a trend toward a decline in serum melatonin and cortisol concentration. The decreasing trend of cortisol serum level was tested as significant over time (pmelatonin. Overall, these results show that after menopause an acute administration of estrogen during the early diurnal period of the day leads to a significant rapid decrease in cortisol serum values, but to only a partial non significant decrease in melatonin serum values.

  5. Influence of fullerenol C60(OH24 on enzime status in serum of rats after single dose administration of doxorubicine

    Directory of Open Access Journals (Sweden)

    Govedarica Biljana Č.

    2008-01-01

    Full Text Available The antracycline antibiotics have one of the widest areas of use in oncology. The most investigated mechanisms of their antineoplastic activity include: interactions of these antibiotics with DNA, inhibition of topoisomerase II and production of free radicals. However, the side effects of doxorubicin, especially cardiotoxicity, are the limiting factor of its use in cancer therapy. The aim of this research was to investigate the influence of fullerenol С60(ОH24 as a cytoprotector in single doze administration of doxorubicin on the activity of enzymes in serum (CK, AST, ALT, LDH and a-HBDH in rats in in vivo system. Activity of enzymes (CK, LDH, HBDH, AST, and ALT in serume was measured with standard commercial methods. The results of analysis of the samples treated with the combination of fullerenol and doxorubicin show no difference in enzyme activity in comparison with the control group. The results indicate the possibility of using fullerenol as a protector in the therapy with doxorubicin in malign neoplasm.

  6. Single chain variable fragment displaying M13 phage library functionalized magnetic microsphere-based protein equalizer for human serum protein analysis.

    Science.gov (United States)

    Zhu, Guijie; Zhao, Peng; Deng, Nan; Tao, Dingyin; Sun, Liangliang; Liang, Zhen; Zhang, Lihua; Zhang, Yukui

    2012-09-18

    Single chain variable fragment (scFv) displaying the M13 phage library was covalently immobilized on magnetic microspheres and used as a protein equalizer for the treatment of human serum. First, scFv displaying M13 phage library functionalized magnetic microspheres (scFv@M13@MM) was incubated with a human serum sample. Second, captured proteins on scFv@M13@MM were eluted with 2 M NaCl, 50 mM glycine-hydrochloric acid (Gly-HCl), and 20% (v/v) acetonitrile with 0.5% (v/v) trifluoroacetic acid in sequence. Finally, the tightly bonded proteins were released by the treatment with thrombin. The eluates were first analyzed by sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE) with silver staining. Results indicated that the difference of protein concentration was reduced obviously in NaCl and Gly-HCl fractions compared with untreated human serum sample. The eluates were also digested with trypsin, followed by online 2D-strong cation exchange (SCX)-RPLC-ESI-MS/MS analysis. Results demonstrated that the number of proteins identified from an scFv@M13@MM treated human serum sample was improved 100% compared with that from the untreated sample. In addition, the spectral count of 10 high abundance proteins (serum albumin, serotransferrin, α-2-macroglobulin, α-1-antitrypsin, apolipoprotein B-100, Ig γ-2 chain C region, haptoglobin, hemopexin, α-1-acid glycoprotein 1, and α-2-HS-glycoprotein) decreased evidently after scFv@M13@MM treatment. All these results demonstrate that scFv@M13@MM could efficiently remove high-abundance proteins, reduce the protein concentration difference of human serum, and result in more protein identification.

  7. Genotyping of human parvovirus B19 in clinical samples from Brazil and Paraguay using heteroduplex mobility assay, single-stranded conformation polymorphism and nucleotide sequencing

    Directory of Open Access Journals (Sweden)

    Marcos César Lima de Mendonça

    2011-06-01

    Full Text Available Heteroduplex mobility assay, single-stranded conformation polymorphism and nucleotide sequencing were utilised to genotype human parvovirus B19 samples from Brazil and Paraguay. Ninety-seven serum samples were collected from individuals presenting with abortion or erythema infectiosum, arthropathies, severe anaemia and transient aplastic crisis; two additional skin samples were collected by biopsy. After the procedure, all clinical samples were classified as genotype 1.

  8. Single-stage mass spectrometric analyses of resin bead samples

    Energy Technology Data Exchange (ETDEWEB)

    Smith, D. H.; Walker, R. L.; Bertram, L. K.; Carter, J. A.

    1978-10-01

    Plutonium and uranium from dissolver solutions loaded on resin beads can be analyzed on single-stage mass spectrometers with little or no degradation of results provided proper care is exercised with regard to sample handling techniques. Additionally, storage of samples on resin beads is feasible for periods at least as long as six months provided the beads are not exposed to residual HNO/sub 3/ and air; it is probable that beads will retain their integrity much longer than six months when stored under collodion, but as yet no data to support this contention have been collected. Conventional or commercial mass spectrometers can readily be adapted to the resin bead technique by installing a pulse-counting detection system. The cost of such conversion will vary depending on whether or not a data acquisition system will be needed. A reasonable estimate is that the cost will be in the neighborhood of $15,000; this figure includes the price of a multi-channel analyzer to serve as a temporary data storage device, but does not include the cost of a computer. It does not appear that it will be practicable to switch easily back and forth between pulse-counting and current integration modes unless the instrument is provided with a movable Faraday cup. Using the same multiplier in both modes would undoubtedly degrade its performance in each. The requirements of low background counting rates and high gain for pulse counting, and of relatively high signal handling capacity in current integration are mutually incompatible if demanded of the same multiplier.

  9. Comparative Analysis of Clinical Samples Showing Weak Serum Reaction on AutoVue System Causing ABO Blood Typing Discrepancies.

    Science.gov (United States)

    Jo, Su Yeon; Lee, Ju Mi; Kim, Hye Lim; Sin, Kyeong Hwa; Lee, Hyeon Ji; Chang, Chulhun Ludgerus; Kim, Hyung Hoi

    2017-03-01

    ABO blood typing in pre-transfusion testing is a major component of the high workload in blood banks that therefore requires automation. We often experienced discrepant results from an automated system, especially weak serum reactions. We evaluated the discrepant results by the reference manual method to confirm ABO blood typing. In total, 13,113 blood samples were tested with the AutoVue system; all samples were run in parallel with the reference manual method according to the laboratory protocol. The AutoVue system confirmed ABO blood typing of 12,816 samples (97.7%), and these results were concordant with those of the manual method. The remaining 297 samples (2.3%) showed discrepant results in the AutoVue system and were confirmed by the manual method. The discrepant results involved weak serum reactions (serum reactions, samples from patients who had received stem cell transplants, ABO subgroups, and specific system error messages. Among the 98 samples showing ≤1+ reaction grade in the AutoVue system, 70 samples (71.4%) showed a normal serum reaction (≥2+ reaction grade) with the manual method, and 28 samples (28.6%) showed weak serum reaction in both methods. ABO blood tying of 97.7% samples could be confirmed by the AutoVue system and a small proportion (2.3%) needed to be re-evaluated by the manual method. Samples with a 2+ reaction grade in serum typing do not need to be evaluated manually, while those with ≤1+ reaction grade do.

  10. Development of an isotope dilution GC-MS procedure for the routine determination of creatinine in complex serum samples.

    Science.gov (United States)

    Fernández-Fernández, Mario; González-Antuña, Ana; Rodríguez-González, Pablo; Añón Álvarez, M Elena; Álvarez, Francisco V; García Alonso, J Ignacio

    2014-04-20

    The accurate determination of creatinine in serum is essential for the diagnosis and treatment of kidney diseases. The determination of serum creatinine in clinical laboratories is routinely carried out by the Jaffe method or by enzymatic methods that may suffer from interferences. So, the development of reliable, fast and interference-free routine methods for complex serum samples is required. A fast method using isotope dilution mass spectrometry (IDMS) and gas chromatography mass spectrometry (GC-MS) was developed using minimally (13)C labeled creatinine analogs, multiple linear regression and rapid derivatization of creatinine with acetylacetone in 2 min by using focused microwave technology. The proposed method was validated with the analyses of two Certified Reference Materials (ERM-DA252a and ERM-DA253a) and compared with the Jaffe and enzymatic methods when analyzing real serum samples containing variable levels of bilirubin The proposed method is capable of providing accurate serum creatinine concentrations in less than 45 min from sample arrival to full data treatment and can be an alternative routine procedure for creatinine determinations in complex serum samples. Copyright © 2014 Elsevier B.V. All rights reserved.

  11. Comparing identified and statistically significant lipids and polar metabolites in 15-year old serum and dried blood spot samples for longitudinal studies: Comparing lipids and metabolites in serum and DBS samples

    Energy Technology Data Exchange (ETDEWEB)

    Kyle, Jennifer E. [Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland WA USA; Casey, Cameron P. [Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland WA USA; Stratton, Kelly G. [National Security Directorate, Pacific Northwest National Laboratory, Richland WA USA; Zink, Erika M. [Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland WA USA; Kim, Young-Mo [Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland WA USA; Zheng, Xueyun [Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland WA USA; Monroe, Matthew E. [Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland WA USA; Weitz, Karl K. [Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland WA USA; Bloodsworth, Kent J. [Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland WA USA; Orton, Daniel J. [Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland WA USA; Ibrahim, Yehia M. [Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland WA USA; Moore, Ronald J. [Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland WA USA; Lee, Christine G. [Department of Medicine, Bone and Mineral Unit, Oregon Health and Science University, Portland OR USA; Research Service, Portland Veterans Affairs Medical Center, Portland OR USA; Pedersen, Catherine [Department of Medicine, Bone and Mineral Unit, Oregon Health and Science University, Portland OR USA; Orwoll, Eric [Department of Medicine, Bone and Mineral Unit, Oregon Health and Science University, Portland OR USA; Smith, Richard D. [Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland WA USA; Burnum-Johnson, Kristin E. [Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland WA USA; Baker, Erin S. [Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland WA USA

    2017-02-05

    The use of dried blood spots (DBS) has many advantages over traditional plasma and serum samples such as smaller blood volume required, storage at room temperature, and ability for sampling in remote locations. However, understanding the robustness of different analytes in DBS samples is essential, especially in older samples collected for longitudinal studies. Here we analyzed DBS samples collected in 2000-2001 and stored at room temperature and compared them to matched serum samples stored at -80°C to determine if they could be effectively used as specific time points in a longitudinal study following metabolic disease. Four hundred small molecules were identified in both the serum and DBS samples using gas chromatograph-mass spectrometry (GC-MS), liquid chromatography-MS (LC-MS) and LC-ion mobility spectrometry-MS (LC-IMS-MS). The identified polar metabolites overlapped well between the sample types, though only one statistically significant polar metabolite in a case-control study was conserved, indicating degradation occurs in the DBS samples affecting quantitation. Differences in the lipid identifications indicated that some oxidation occurs in the DBS samples. However, thirty-six statistically significant lipids correlated in both sample types indicating that lipid quantitation was more stable across the sample types.

  12. Usefulness of in-house real time PCR for HBV DNA quantification in serum and oral fluid samples.

    Science.gov (United States)

    Portilho, Moyra Machado; Mendonça, Ana Carolina da Fonseca; Bezerra, Cristianne Sousa; do Espirito-Santo, Márcia Paschoal; de Paula, Vanessa Salete; Nabuco, Leticia Cancella; Villela-Nogueira, Cristiane Alves; Lewis-Ximenez, Lia Laura; Lampe, Elisabeth; Villar, Livia Melo

    2018-06-01

    For quantification of hepatitis B virus DNA (HBV DNA), commercial assays are used with serum or plasma samples, but oral fluid samples could be an alternative for HBV diagnosis due to ease of collection. This study aims to develop in-house real time PCR using synthetic curve for HBV DNA quantification for serum and oral fluid samples. Samples were collected from 103 individuals (55 HBsAg reactive and HBV DNA reactive by commercial assay and 48 without HBV markers) and submitted to two in-house real time PCR assays for HBV pre-S/S region with different standard curves: qPCR plasmidial and qPCR synthetic. A total of 27 serum samples were HBV DNA positive by qPCR plasmidial and 40 with qPCR synthetic (72% and 85% of concordance, respectively). Quantitative PCR synthetic presented efficiency of 99% and sensitivity of 2log10 copies/mL. Among oral fluid samples, five and ten were detected using qPCR plasmidial and synthetic, respectively. This study demonstrated that qPCR synthetic using serum samples could be used as alternative for HBV DNA quantification due to its sensitivity. In addition, it was possible to quantify HBV DNA in oral fluid samples suggesting the potential of this specimen for molecular diagnosis of HBV. Copyright © 2018 Elsevier B.V. All rights reserved.

  13. Slurry sampling in serum blood for mercury determination by CV-AFS

    Energy Technology Data Exchange (ETDEWEB)

    Aranda, Pedro R. [Departmento de Quimica Analitica, Facultad de Quimica, Bioquimica y Farmacia, Universidad Nacional de San Luis, Chacabuco y Pedernera, P.O. Box 375, 5700 San Luis (Argentina); Instituto de Quimica San Luis (INQUISAL-CONICET), Chacabuco y Pedernera, P.O. Box 375, 5700 San Luis (Argentina)], E-mail: paranda@unsl.edu.ar; Gil, Raul A. [Departmento de Quimica Analitica, Facultad de Quimica, Bioquimica y Farmacia, Universidad Nacional de San Luis, Chacabuco y Pedernera, P.O. Box 375, 5700 San Luis (Argentina); Instituto de Quimica San Luis (INQUISAL-CONICET), Chacabuco y Pedernera, P.O. Box 375, 5700 San Luis (Argentina)], E-mail: ragil@unsl.edu.ar; Moyano, Susana [Departmento de Quimica Analitica, Facultad de Quimica, Bioquimica y Farmacia, Universidad Nacional de San Luis, Chacabuco y Pedernera, P.O. Box 375, 5700 San Luis (Argentina)], E-mail: smoyano@unsl.edu.ar; De Vito, Irma [Departmento de Quimica Analitica, Facultad de Quimica, Bioquimica y Farmacia, Universidad Nacional de San Luis, Chacabuco y Pedernera, P.O. Box 375, 5700 San Luis (Argentina)], E-mail: devito@unsl.edu.ar; Martinez, Luis D. [Departmento de Quimica Analitica, Facultad de Quimica, Bioquimica y Farmacia, Universidad Nacional de San Luis, Chacabuco y Pedernera, P.O. Box 375, 5700 San Luis (Argentina); Instituto de Quimica San Luis (INQUISAL-CONICET), Chacabuco y Pedernera, P.O. Box 375, 5700 San Luis (Argentina)], E-mail: ldm@unsl.edu.ar

    2009-01-30

    The heavy metal mercury (Hg) is a neurotoxin known to have a serious health impact even at relatively low concentrations. A slurry method was developed for the sensitive and precise determination of mercury in human serum blood samples by cold vapor generation coupled to atomic fluorescence spectrometry (CV-AFS). All variables related to the slurry formation were studied. The optimal hydrochloric concentration and tin(II) chloride concentration for CV generation were evaluated. Calibration within the range 0.1-10 {mu}g L{sup -1} Hg was performed with the standard addition method, and compared with an external calibration. Additionally, the reliability of the results obtained was evaluated by analyzing mercury in the same samples, but submitted to microwave-assisted digestion method. The limit of detection was calculated as 25 ng L{sup -1} and the relative standard deviation was 3.9% at levels around of 0.4 {mu}g L{sup -1} Hg.

  14. Retrospective analysis of dengue specific IgM reactive serum samples

    Directory of Open Access Journals (Sweden)

    Nemai Bhattacharya

    2013-04-01

    Full Text Available Objective: To conduct a retrospective analysis of dengue cases in Kolkata, on the basis of presence of anti-dengue IgM in their sera and presence or absence of anti-dengue IgG and dengue specific Non structural 1 (NS1 antigen in each of the serum sample. Methods: Sample was tested quantitatively employing ELISA technique, using Biorad test kits, with a view to get a more comprehensive picture of dengue in an urban endemic area and also to evaluate individual cases. Results: This reconstructed study revealed that of those 91 dengue cases, 70.3% (64 and 29.7% (27 were suffering from secondary and primary dengue respectively, showing that number of secondary dengue cases were much more than that of primary dengue cases with a possibility of emergence of DHF. A small proportion of cases 18.7% (17 were reactive for NS1. The duration of fever in NS1 antigen positive cases varied between 5 and 7 days. Of 17 NS1 reactive cases, 10 (10.9% and 7 (7.7% were suffering from secondary and primary dengue respectively. Conclusions: Early detection of primary and secondary dengue cases would be facilitated by utilizing all three parameters (NS1 antigen, anti-dengue IgM and IgG helping to evaluate, monitor and treat a dengue case effectively.

  15. Serum cadmium levels in a sample of blood donors in the Western Amazon, Brazil, 2010-2011

    Directory of Open Access Journals (Sweden)

    Andre Ricardo Maia da Costa de Faro

    2014-02-01

    Full Text Available A cross-sectional study was conducted to determine the distribution of serum cadmium (Cd levels in blood donors in Rio Branco, Acre State, Brazil. Blood samples were obtained from 922 volunteer blood donors from 18 to 65 years of age at the Hemoacre blood center in 2010-2011. Mean serum Cd was 0.37µg/L (95%CI: 0.33-0.41. Increased serum Cd was associated with lower schooling; individuals with less than five years of schooling showed a mean Cd of 0.61µg/L (95%CI: 0.34-0.89, compared to 0.34µg/L (95%CI: 0.28-0.40 among those with more than nine years of schooling. Mean serum Cd was three times higher among smokers. Smoking showed a positive association with Cd level, with an OR of 12.36 (95%CI: 7.70-19.84. Meanwhile, serum Cd was lower among individuals that regularly drank tea, as compared to non-tea drinkers. Serum Cd levels were mostly below the reference value (88.3% of participants. Mean serum Cd in the current study indicates that in general the population studied here is not exposed to worrisome Cd levels.

  16. Development of a Single-Sampling Noninvasive Hair Snare

    DEFF Research Database (Denmark)

    Bremner-Harrison, Samantha; Harrison, Stephen W. R.; Cypher, Brian L.

    2006-01-01

    Noninvasive hair and fecal DNA sampling provides a means of collecting information on elusive species, while causing little or no disturbance. However, current methods of hair collection do not preclude multiple sampling, thus risking sample contamination. We developed a hair snare that prevents ...

  17. Reliability of Serum Metabolites over a Two-Year Period: A Targeted Metabolomic Approach in Fasting and Non-Fasting Samples from EPIC

    Science.gov (United States)

    Achaintre, David; Sacerdote, Carlotta; Vineis, Paolo; Key, Timothy J.; Onland Moret, N. Charlotte; Scalbert, Augustin; Rinaldi, Sabina; Ferrari, Pietro

    2015-01-01

    Objective Although metabolic profiles have been associated with chronic disease risk, lack of temporal stability of metabolite levels could limit their use in epidemiological investigations. The present study aims to evaluate the reliability over a two-year period of 158 metabolites and compare reliability over time in fasting and non-fasting serum samples. Methods Metabolites were measured with the AbsolueIDQp180 kit (Biocrates, Innsbruck, Austria) by mass spectrometry and included acylcarnitines, amino acids, biogenic amines, hexoses, phosphatidylcholines and sphingomyelins. Measurements were performed on repeat serum samples collected two years apart in 27 fasting men from Turin, Italy, and 39 non-fasting women from Utrecht, The Netherlands, all participating in the European Prospective Investigation into Cancer and Nutrition (EPIC) study. Reproducibility was assessed by estimating intraclass correlation coefficients (ICCs) in multivariable mixed models. Results In fasting samples, a median ICC of 0.70 was observed. ICC values were fasting samples, the median ICC was 0.54. ICC values were fasting as compared to fasting samples, with a statistically significant difference for 19–36% of acylcarnitines, phosphatidylcholines and sphingomyelins. Conclusion A single measurement per individual may be sufficient for the study of 73% and 52% of the metabolites showing ICCs >0.50 in fasting and non-fasting samples, respectively. ICCs were higher in fasting samples that are preferable to non-fasting. PMID:26274920

  18. Hypospadias and halogenated organic pollutant levels in maternal mid-pregnancy serum samples

    Science.gov (United States)

    Carmichael, Suzan L; Herring, Amy H; Sjödin, Andreas; Jones, Richard; Needham, Larry; Ma, Chen; Ding, Kai; Shaw, Gary M

    2010-01-01

    Background Environmental contaminants that disrupt endocrine function may contribute to hypospadias etiology. Objective To compare levels of selected halogenated organic pollutants in women delivering infants with and without hypospadias. Methods This study examined levels of nine polybrominated flame retardants (PBDEs), 30 polychlorinated biphenyls (PCBs) and nine persistent pesticides in mid-pregnancy serum samples from 20 women who delivered infants with hypospadias and 28 women who delivered unaffected infants, in California. Analytes were measured using isotope dilution high-resolution mass spectrometry. Values below individual limits of detection (LOD) for each analyte were imputed based on a truncated multivariate normal distribution. Levels of 17 analytes for which at least 50% of cases and controls had values above the LOD were compared using t-tests and by generating odds ratios from logistic regression analyses. Results Means were greater for cases than controls for 11 of the 17 reported analytes (4 of 5 PBDEs, 7 of 9 PCBs, and 0 of 3 other persistent pesticides), but none of the differences were statistically significant. Eleven of the 17 odds ratios exceeded one (the same analytes that had greater means), but none of the confidence intervals excluded one. After adjustment for sample processing time and foreign-born Hispanic race-ethnicity, only four of the odds ratios exceeded one. Conclusions Levels of the PBDEs and PCBs were not statistically significantly different, but the sample size was small. The current study adds to a relatively limited knowledge base regarding the potential association of specific contaminants with hypospadias or other birth defects. PMID:20494400

  19. Directional emission of single photons from small atomic samples

    DEFF Research Database (Denmark)

    Miroshnychenko, Yevhen; V. Poulsen, Uffe; Mølmer, Klaus

    2013-01-01

    We provide a formalism to describe deterministic emission of single photons with tailored spatial and temporal profiles from a regular array of multi-level atoms. We assume that a single collective excitation is initially shared by all the atoms in a metastable atomic state, and that this state i...... is coupled by a classical laser field to an optically excited state which rapidly decays to the ground atomic state. Our model accounts for the different field polarization components via re-absorption and emission of light by the Zeeman manifold of optically excited states.......We provide a formalism to describe deterministic emission of single photons with tailored spatial and temporal profiles from a regular array of multi-level atoms. We assume that a single collective excitation is initially shared by all the atoms in a metastable atomic state, and that this state...

  20. Stability of BDNF in Human Samples Stored Up to 6 Months and Correlations of Serum and EDTA-Plasma Concentrations.

    Science.gov (United States)

    Polyakova, Maryna; Schlögl, Haiko; Sacher, Julia; Schmidt-Kassow, Maren; Kaiser, Jochen; Stumvoll, Michael; Kratzsch, Jürgen; Schroeter, Matthias L

    2017-06-03

    Brain-derived neurotrophic factor (BDNF), an important neural growth factor, has gained growing interest in neuroscience, but many influencing physiological and analytical aspects still remain unclear. In this study we assessed the impact of storage time at room temperature, repeated freeze/thaw cycles, and storage at -80 °C up to 6 months on serum and ethylenediaminetetraacetic acid (EDTA)-plasma BDNF. Furthermore, we assessed correlations of serum and plasma BDNF concentrations in two independent sets of samples. Coefficients of variations (CVs) for serum BDNF concentrations were significantly lower than CVs of plasma concentrations ( n = 245, p = 0.006). Mean serum and plasma concentrations at all analyzed time points remained within the acceptable change limit of the inter-assay precision as declared by the manufacturer. Serum and plasma BDNF concentrations correlated positively in both sets of samples and at all analyzed time points of the stability assessment ( r = 0.455 to r s = 0.596; p plasma up to 6 months. Due to a higher reliability, we suggest favoring serum over EDTA-plasma for future experiments assessing peripheral BDNF concentrations.

  1. Development of a Single-Sampling Noninvasive Hair Snare

    DEFF Research Database (Denmark)

    Bremner-Harrison, Samantha; Harrison, Stephen W. R.; Cypher, Brian L.

    2006-01-01

    Noninvasive hair and fecal DNA sampling provides a means of collecting information on elusive species, while causing little or no disturbance. However, current methods of hair collection do not preclude multiple sampling, thus risking sample contamination. We developed a hair snare that prevents...... multiple sampling, is cost-effective, easy to construct, and safe for target and nontarget species. Our initial field tests on endangered San Joaquin kit foxes (Vulpes macrotis mutica) and swift foxes (Vulpes velox) suggest that this hair snare may be effective in collecting uncontaminated samples for DNA...

  2. Pneumatic tube-transported blood samples in lithium heparinate gel separator tubes may be more susceptible to haemolysis than blood samples in serum tubes.

    Science.gov (United States)

    Böckel-Frohnhöfer, Nicole; Hübner, Ulrich; Hummel, Björn; Geisel, Jürgen

    2014-10-01

    Pneumatic tube systems are widely used in hospitals. Advantages are high speed and rapid availability of the samples. However, the transportation by pneumatic tube promotes haemolysis. Haemolysis interferes with many spectrophotometric assays and is a common problem in clinical laboratories. The haemolysis index (HI) as a semi-quantitative representation of the level of haemolysis was compared in unpaired tube-transported and hand-delivered routine lithium heparinate plasma samples (n = 1368 and n = 837, respectively). Additionally, the HI distribution was measured in lithium heparinate plasma samples with a HI above the threshold value of 20 and in paired serum samples after transportation by pneumatic tube system. HI values above 20 can interfere with the selected assays: Creatine kinase (CK), creatine kinase-MB (CK-MB) and alanine aminotransferase (ALT) activities. These parameters were determined to demonstrate how haemolysis affects the results. 17.5% of the tube-transported plasma samples and 2.6% of the hand-delivered plasma samples had a HI above 20. The median HI in pneumatic tube-transported lithium heparinate plasma was 85 and 33 in the paired serum samples. The median HI difference between paired plasma and serum was 46. Blood samples in lithium heparinate tubes may be substantially more susceptible to haemolysis by pneumatic tube transportation than serum tube samples. Although our results cannot be universally applied to laboratories with different pneumatic tube systems, it is recommended that each laboratory evaluate carefully the degree of haemolysis after the transportation by the own pneumatic tube system and in terms of the sample type.

  3. Parathormone stability in hemodialyzed patients and healthy subjects: comparison on non-centrifuged EDTA and serum samples with second- and third-generation assays.

    Science.gov (United States)

    Schleck, Marie-Louise; Souberbielle, Jean-Claude; Delanaye, Pierre; Plebani, Mario; Cavalier, Etienne

    2017-07-26

    Parathyroid hormone (PTH) stability is important. Many studies have shown divergent results between EDTA and serum, which are mainly linked to differences in protocols or cut-offs used to determine whether or not PTH remained stable. No studies have yet compared PTH stability as measured by second- and third-generation assays on the same samples in hemodialyzed patients and healthy subjects. Five pairs of samples (EDTA and gel tubes) were obtained in 10 hemodialyzed patients before a dialysis session and in 10 healthy subjects. One pair was centrifuged and run directly to define the "T0". Two pairs were kept at +4°C and two pairs were kept at +25°C. They were centrifuged after 4 and 18 h. Supernatant was kept at -80°C for 1 week. All samples were measured in a single batch, on Roche Cobas and DiaSorin XL second- and third-generation PTH assays. We used three different approaches to evaluate PTH stability: Wilcoxon test, an Acceptable Change Limit (ACL) according to ISO Guide 5725-6 and a Total Change Limit (TCL) derived from the sum of biological and technical variability according to WHO. PTH decreased in all samples. Stability of PTH was mainly dependent on the way it was evaluated. Percentages of decrease were systematically lower in EDTA vs. serum. Wilcoxon and ACL showed that PTH was no more stable after 4 h at +4°C in EDTA or serum gel tubes. None of the subjects presented a PTH decrease higher than the TCL with EDTA plasma. In serum gel tubes, PTH was unstable only when kept at 25°C for 18 h. PTH seems more stable in EDTA than in serum gel tubes but only when samples have to stay unprocessed for a long period (18 h) at room temperature (25°C), which can happen when samples are delivered from external care centers. For all the other conditions, using serum gel tubes is recommended since calcium measurement, which is necessary for a good PTH results interpretation, can be achieved on the same tube.

  4. microRNA Biomarker Discovery and High-Throughput DNA Sequencing Are Possible Using Long-term Archived Serum Samples.

    Science.gov (United States)

    Rounge, Trine B; Lauritzen, Marianne; Langseth, Hilde; Enerly, Espen; Lyle, Robert; Gislefoss, Randi E

    2015-09-01

    The impacts of long-term storage and varying preanalytical factors on the quality and quantity of DNA and miRNA from archived serum have not been fully assessed. Preanalytical and analytical variations and degradation may introduce bias in representation of DNA and miRNA and may result in loss or corruption of quantitative data. We have evaluated DNA and miRNA quantity, quality, and variability in samples stored up to 40 years using one of the oldest prospective serum collections in the world, the Janus Serumbank, a biorepository dedicated to cancer research. miRNAs are present and stable in archived serum samples frozen at -25°C for at least 40 years. Long-time storage did not reduce miRNA yields; however, varying preanalytical conditions had a significant effect and should be taken into consideration during project design. Of note, 500 μL serum yielded sufficient miRNA for qPCR and small RNA sequencing and on average 650 unique miRNAs were detected in samples from presumably healthy donors. Of note, 500 μL serum yielded sufficient DNA for whole-genome sequencing and subsequent SNP calling, giving a uniform representation of the genomes. DNA and miRNA are stable during long-term storage, making large prospectively collected serum repositories an invaluable source for miRNA and DNA biomarker discovery. Large-scale biomarker studies with long follow-up time are possible utilizing biorepositories with archived serum and state-of-the-art technology. ©2015 American Association for Cancer Research.

  5. Soluble CD44 concentration in the serum and peritoneal fluid samples of patients with different stages of endometriosis.

    Science.gov (United States)

    Mashayekhi, Farhad; Aryaee, Hadis; Mirzajani, Ebrahim; Yasin, Ashraf Ale; Fathi, Abdolsatar

    2015-09-01

    Endometriosis is a gynecological disease defined by the histological presence of endometrial glands and stroma outside the uterine cavity, most commonly implanted over visceral and peritoneal surface within the female pelvis. CD44 is a membrane protein expressed by human endometrial cells, and it has been shown to promote the adhesion of endometrial cells. The aim of this study was to determine the levels of soluble CD44 (sCD44) in the serum and peritoneal fluid (PF) samples of patients with different stages of endometriosis. 39 PF and serum samples from normal healthy and 130 samples from different stages of patients with endometriosis (33 cases of stage I, 38 stage II, 30 stage III and 29 stage IV) were included in this study. Total protein concentration (TPC) and the level of s-cMet in the serum were determined by Bio-Rad protein assay based on the Bradford dye procedure and enzyme-linked immunosorbent assay, respectively. No significant change in the TPC was seen in the serum of patients with endometriosis when compared to normal controls. Results obtained demonstrated that all serum and peritoneal fluid samples, presented sCD44 expression, whereas, starting from stages I to IV endometriosis, a significant increase of sCD44 expression was observed as compared to control group. The results of this study show that a high expression of sCD44 is correlated with advanced stages of endometriosis. It is also concluded that the detection of serum and/or peritoneal fluid sCD44 may be useful in classifying endometriosis.

  6. Influence of common preanalytical variations on the metabolic profile of serum samples in biobanks

    Energy Technology Data Exchange (ETDEWEB)

    Fliniaux, Ophelie [University of Picardie Jules Verne, Laboratoire de Phytotechnologie EA 3900-BioPI (France); Gaillard, Gwenaelle [Biobanque de Picardie (France); Lion, Antoine [University of Picardie Jules Verne, Laboratoire de Phytotechnologie EA 3900-BioPI (France); Cailleu, Dominique [Batiment Serres-Transfert, rue de Mai/rue Dallery, Plateforme Analytique (France); Mesnard, Francois, E-mail: francois.mesnard@u-picardie.fr [University of Picardie Jules Verne, Laboratoire de Phytotechnologie EA 3900-BioPI (France); Betsou, Fotini [Integrated Biobank of Luxembourg (Luxembourg)

    2011-12-15

    A blood pre-centrifugation delay of 24 h at room temperature influenced the proton NMR spectroscopic profiles of human serum. A blood pre-centrifugation delay of 24 h at 4 Degree-Sign C did not influence the spectroscopic profile as compared with 4 h delays at either room temperature or 4 Degree-Sign C. Five or ten serum freeze-thaw cycles also influenced the proton NMR spectroscopic profiles. Certain common in vitro preanalytical variations occurring in biobanks may impact the metabolic profile of human serum.

  7. Influence of common preanalytical variations on the metabolic profile of serum samples in biobanks

    International Nuclear Information System (INIS)

    Fliniaux, Ophélie; Gaillard, Gwenaelle; Lion, Antoine; Cailleu, Dominique; Mesnard, François; Betsou, Fotini

    2011-01-01

    A blood pre-centrifugation delay of 24 h at room temperature influenced the proton NMR spectroscopic profiles of human serum. A blood pre-centrifugation delay of 24 h at 4°C did not influence the spectroscopic profile as compared with 4 h delays at either room temperature or 4°C. Five or ten serum freeze–thaw cycles also influenced the proton NMR spectroscopic profiles. Certain common in vitro preanalytical variations occurring in biobanks may impact the metabolic profile of human serum.

  8. Reliable single cell array CGH for clinical samples.

    Directory of Open Access Journals (Sweden)

    Zbigniew T Czyż

    Full Text Available BACKGROUND: Disseminated cancer cells (DCCs and circulating tumor cells (CTCs are extremely rare, but comprise the precursors cells of distant metastases or therapy resistant cells. The detailed molecular analysis of these cells may help to identify key events of cancer cell dissemination, metastatic colony formation and systemic therapy escape. METHODOLOGY/PRINCIPAL FINDINGS: Using the Ampli1™ whole genome amplification (WGA technology and high-resolution oligonucleotide aCGH microarrays we optimized conditions for the analysis of structural copy number changes. The protocol presented here enables reliable detection of numerical genomic alterations as small as 0.1 Mb in a single cell. Analysis of single cells from well-characterized cell lines and single normal cells confirmed the stringent quantitative nature of the amplification and hybridization protocol. Importantly, fixation and staining procedures used to detect DCCs showed no significant impact on the outcome of the analysis, proving the clinical usability of our method. In a proof-of-principle study we tracked the chromosomal changes of single DCCs over a full course of high-dose chemotherapy treatment by isolating and analyzing DCCs of an individual breast cancer patient at four different time points. CONCLUSIONS/SIGNIFICANCE: The protocol enables detailed genome analysis of DCCs and thereby assessment of the clonal evolution during the natural course of the disease and under selection pressures. The results from an exemplary patient provide evidence that DCCs surviving selective therapeutic conditions may be recruited from a pool of genomically less advanced cells, which display a stable subset of specific genomic alterations.

  9. Resolution of a serum sample mix-up through the use of short tandem repeat DNA typing.

    Science.gov (United States)

    Allen, Robert W; Pritchard, Jane K

    2004-12-01

    A sample mix-up occurred in a tissue procurement laboratory in which aliquots of serum from two tissue donors were accidentally mislabeled. The clues to the apparent mixup involved discrepant Hepatitis C test results. In an attempt to resolve the apparent mix up, DNA typing was performed using serum samples as a possible source of genomic DNA. Two hundred microliter aliquots of two reference sera and aliquots prepared from them were subjected to DNA extraction. PCR amplification of 9 STR loci was performed on the extracts and amplicons were analyzed by capillary electrophoresis. About 1 microg/ml of DNA was recovered from all serum samples and was of sufficient quality to direct the amplification of most, if not all STR loci allowing the mislabeled specimens to be traced to the proper tissue donor. Serum is a useful source of genomic DNA for STR analysis in situations in which such samples are the only source of DNA for testing. Interestingly, one of the tissue donors on life support and repeatedly receiving blood products, exhibited a mixed DNA profile indicative of the presence of DNA from multiple individuals in the bloodstream.

  10. Limited interlaboratory comparison of Schmallenberg virus antibody detection in serum samples

    DEFF Research Database (Denmark)

    van der Poel, W. H. M.; Cay, B.; Zientara, S.

    2014-01-01

    Eight veterinary institutes in seven different countries in Europe participated in a limited interlaboratory comparison trial to evaluate laboratory performances of Schmallenberg virus (SBV) antibody detection in serum. Seven different sheep sera and three different cattle sera were circulated, a...

  11. Comparison of different methods for extraction and purification of human Papillomavirus (HPV) DNA from serum samples

    Science.gov (United States)

    Azizah, N.; Hashim, U.; Nadzirah, Sh.; Arshad, M. K. Md; Ruslinda, A. R.; Gopinath, Subash C. B.

    2017-03-01

    The affectability and unwavering quality of PCR for indicative and research purposes require effective fair systems of extraction and sanitization of nucleic acids. One of the real impediments of PCR-based tests is the hindrance of the enhancement procedure by substances exhibit in clinical examples. This examination considers distinctive techniques for extraction and cleaning of viral DNA from serum tests in view of recuperation productivity as far as yield of DNA and rate recouped immaculateness of removed DNA, and rate of restraint. The best extraction strategies were the phenol/chloroform strategy and the silica gel extraction methodology for serum tests, individually. Considering DNA immaculateness, extraction technique by utilizing the phenol/chloroform strategy delivered the most tasteful results in serum tests contrasted with the silica gel, separately. The nearness of inhibitors was overcome by all DNA extraction strategies in serum tests, as confirm by semiquantitative PCR enhancement.

  12. Estimations of cholesterol, triglycerides and fractionation of lipoproteins in serum samples of some Nigerian female subjects

    Directory of Open Access Journals (Sweden)

    E.I. Adeyeye

    2011-04-01

    Full Text Available Blood samples (serum were collected to determine some biochemical parameters: total glycerides (TG, total cholesterol (TC, high density lipoprotein-cholesterol (HDL-C, low density lipoprotein-cholesterol (LDL-C and very low density lipoprotein-cholesterol (VLDL-C in 53 female subjects in Warri, Delta State, Nigeria using the Reflotron® (an auto analyser, supported with the use of questionnaire to get information on age and sex. Age range of the subjects was 18–80 years. The TG levels in all the subjects were < 200 mg/dL; only one subject (1.89% had TC < 200 mg/dL; nine subjects (17.0% had HDL-C ≤ 35 mg/dL; for LDL-C only one subject (1.89% had a desirable level of < 130 mg/dL; for VLDL-C 29 subjects (54.7% had values 17.2 mg/dL and above. For therapeutic decision-making, TC/HDL-C and LDL-C/HDL-C, were calculated. In TC/HDL-C, three subjects (5.66% had values < 4.4 and in LDL-C/HDL-C, 41 subjects (77.4% had values < 4.5. Hence, TC, HDL-C, LDL-C, TC/HDL-C and slightly LDL-C/HDL-C and VLDL-C in the subjects could lead to increase coronary heart diseases. Results were matched for the age and sex of subjects.

  13. Comparative Analysis of Clinical Samples Showing Weak Serum Reaction on AutoVue System Causing ABO Blood Typing Discrepancies

    OpenAIRE

    Jo, Su Yeon; Lee, Ju Mi; Kim, Hye Lim; Sin, Kyeong Hwa; Lee, Hyeon Ji; Chang, Chulhun Ludgerus; Kim, Hyung-Hoi

    2016-01-01

    Background ABO blood typing in pre-transfusion testing is a major component of the high workload in blood banks that therefore requires automation. We often experienced discrepant results from an automated system, especially weak serum reactions. We evaluated the discrepant results by the reference manual method to confirm ABO blood typing. Methods In total, 13,113 blood samples were tested with the AutoVue system; all samples were run in parallel with the reference manual method according to...

  14. Validation of an isotope dilution gas chromatography-mass spectrometry method for combined analysis of oxysterols and oxyphytosterols in serum samples.

    Science.gov (United States)

    Schött, Hans-Frieder; Lütjohann, Dieter

    2015-07-01

    We describe the validation of a method for the analysis of oxysterols, i.e. oxycholesterols and oxyphytosterols, in human serum using gas chromatography-mass spectrometry selected ion monitoring (GC-MS-SIM). Concentrations of 7α- and 7β-hydroxy-, and 7oxo-cholesterol, -campesterol, and -sitosterol as well as 4β-hydroxycholesterol and side-chain oxygenated 24S-, 25-, and 27-hydroxycholesterol were determined by isotope dilution methodology. After saponification at room temperature the oxysterols were extracted, separated from their substrates, cholesterol, campesterol, and sitosterol, by solid phase extraction, and subsequently derivatised to their corresponding trimethylsilyl-ethers prior to GC-MS-SIM. In order to prevent artificial autoxidation butylated hydroxytoluene and ethylenediaminetetraacetic acid were added. The validation of the method was performed according to the International Conference on Harmonisation guidance, including limits of detection and quantification, ranges, recovery and precision. Due to improved instrumental settings and work-up procedure, limits of detection and quantification ranged between 8.0-202.0pg/mL and 28.0-674pg/mL, respectively. Recovery data in five calibration points varied between 91.9% and 116.8% and in serum samples between 93.1% and 118.1%. The mean coefficient of variation (CV) for the recovery of all compounds was <10%. Well satisfying CVs for within-day precision (2.1-10.8%) and for between-day precision (2.3-12.1%) were obtained. More than 20 samples could be processed in a single routine day and test series of about 300 samples can be realised without impairment of the validation parameters during a sequence. Comparison of oxysterol and oxyphytosterol content in serum and plasma revealed no difference. A fully validated isotope dilution methodology for the quantification of oxycholesterols and oxyphytosterols from human serum or plasma is presented. Copyright © 2015 Elsevier Inc. All rights reserved.

  15. Vapor and gas sampling of single-shell tank 241-U-104 using the in situ vapor sampling system

    International Nuclear Information System (INIS)

    Lockrem, L.L.

    1997-01-01

    The Vapor Issue.Resolution Program tasked the Vapor Team (VT) to collect representative headspace samples from Hanford Site single-shell tank (SST) 241-U-104. This document presents In Situ Vapor Sampling System (ISVS) data resulting from the July 16, 1996 sampling of SST 241-U-104. Analytical results will be presented in separate reports issued by the Pacific Northwest National Laboratory (PNNL) which supplied and analyzed the sample media

  16. Vapor and gas sampling of single-shell tank 241-BX-110 using the in situ vapor sampling system

    International Nuclear Information System (INIS)

    Lockrem, L.L.

    1997-01-01

    The Vapor Issue Resolution Program tasked the Vapor Team (the team) to collect representative headspace samples from Hanford Site single-shell tank (SST) 241-BX-110. This document presents sampling data resulting from the April 30, 1996 sampling of SST 241-BX-110. Analytical results will be presented in a separate report issued by Pacific Northwest National Laboratory (PNNL), which supplied and analyzed the sampling media

  17. Vapor and gas sampling of single-shell tank 241-S-106 using the in situ vapor sampling system

    International Nuclear Information System (INIS)

    Lockrem, L.L.

    1997-01-01

    The Vapor Issue Resolution Program tasked the Vapor Team (VT) to collect representative headspace samples from Hanford Site single-shell tank (SST) 241-S-106. This document presents In Situ vapor Sampling System (ISVS) data resulting from the June 13, 1996 sampling of SST 241-S-106. Analytical results will be presented in separate reports issued by the Pacific Northwest National Laboratory (PNNL) which'supplied and analyzed the sample media

  18. Vapor and gas sampling of single-shell tank 241-S-103 using the in situ vapor sampling system

    International Nuclear Information System (INIS)

    Lockrem, L.L.

    1997-01-01

    The Vapor Issue Resolution Program tasked the Vapor Team (VT) to collect representative headspace samples from Hanford Site single-shell tank (SST) 241-S-103. This document presents In Situ Vapor Sampling System (ISVS) data resulting from the June 12, 1996 sampling of SST 241-S-103. Analytical results will be presented in separate reports issued by the Pacific Northwest National Laboratory (PNNL) which supplied and analyzed the sample media

  19. Predictive value of serum HCG concentrations in pregnancies achieved after single fresh or vitrified-warmed blastocyst transfer.

    Science.gov (United States)

    Oron, Galia; Shavit, Tal; Esh-Broder, Efrat; Weon-Young, Son; Tulandi, Togas; Holzer, Hananel

    2017-09-01

    Possible differences between serum HCG levels in pregnancies achieved after transfer of a single fresh or a vitrified-warmed blastocyst were evaluated. Out of 1130 single blastocyst transfers resulting in positive HCG results, 789 were single fresh blastocyst transfers and 341 single vitrified-warmed blastocyst transfers. The initial serum HCG levels of 869 clinical intrauterine pregnancies were evaluated, 638 after the transfer of a single fresh blastocysts and 231 after the transfer of a single vitrified-warmed blastocysts. The HCG levels from cycles resulting in a clinical intrauterine pregnancy were significantly higher after the transfer of a single vitrified-warmed blastocyst (383 ± 230 IU/l) versus a fresh transfer (334 ± 192 IU/l; P = 0.01). Threshold values for predicting a clinical pregnancy for a fresh blastocyst were 111 IU/l and for a vitrified-warmed blastocyst 137 IU/l. Our study shows that the overall beta-HCG levels are comparable after the transfer of a fresh or vitrified-warmed blastocyst, suggesting that vitrification most probably does not affect the ability of the embryos to produce beta-HCG. This study further shows that when clinicians counsel patients, they should take into account that higher HCG levels are needed after a vitrified-warmed blastocyst transfer to predict a clinical intrauterine pregnancy. Copyright © 2017 Reproductive Healthcare Ltd. Published by Elsevier Ltd. All rights reserved.

  20. Analysis of performance of a PCR-based assay to detect DNA of Aspergillus fumigatus in whole blood and serum: a comparative study with clinical samples.

    Science.gov (United States)

    Bernal-Martínez, Leticia; Gago, Sara; Buitrago, María J; Gomez-Lopez, Alicia; Rodríguez-Tudela, Juan L; Cuenca-Estrella, Manuel

    2011-10-01

    The performance of a real-time PCR-based assay was retrospectively analyzed (according to European Organization for Research and Treatment of Cancer/Mycosis Study Group criteria) in the samples of patients with invasive aspergillosis. A total of 711 serial samples (356 whole-blood and 355 serum samples) from 38 adult patients were analyzed. The Aspergillus fumigatus PCR assay results were positive for 89 of 356 (25%) whole-blood samples and 90 of 355 (25.35%) serum samples. Positive PCR results were seen in 29 of 31 (93.5%) patients for which serum was analyzed and in 31 of 33 (93.9%) cases with whole-blood specimens. Both blood and serum samples were available in 26 cases, and significant differences were not observed in this subgroup of cases. The average number of threshold cycles (C(T)) for positive blood samples was 37.6, and the average C(T) for serum was 37.4. The DNA concentration ranged between 2 and 50 fg per μl of sample, with average DNA concentrations of 10.2 and 11.7 fg in positive blood and serum samples, respectively (P > 0.01). The performance of this PCR-based quantitative assay was similar for both serum and blood samples. We recommend serum samples as the most convenient hematological sample to use for Aspergillus DNA quantification when serial determinations are done.

  1. A single serum dilution enzyme-linked immunosorbent assay for determining anti-human papillomavirus (HPV) antibody titres in humans immunised with prophylactic HPV vaccines.

    Science.gov (United States)

    Jin, Yingji; Kim, Hyoung Jin; Yim, Ga Won; Kim, Young Tae; Chang, Don Yong; Kim, Hong-Jin

    2012-07-01

    Two types of prophylactic human papillomavirus (HPV) vaccines are currently available. However, there is no simple monitoring system for assessing acquired immunity that can cope simultaneously with large numbers of serum samples. Approximately 30% of women with normal cytology are known to be seropositive for HPV types 16 and 18 because of the high prevalence of these HPV types. Therefore, to be useful the monitoring system has to discriminate clearly between vaccine recipients and other serology groups. However, there has never been any focus on developing a method to satisfy this condition. In this study, we developed a high-throughput single-serum-dilution enzyme-linked immunoassay (ELISA) system for determining anti-HPV antibody titres following vaccination. We optimised the conditions for each ELISA step to increase its accuracy and precision and to avoid the high background of non-specific reactions that is a major problem for serology assays. The new ELISA system has superior linearity, accuracy and reproducibility. Moreover, it clearly discriminated between antibody levels in vaccine recipients and those in other serology groups such as individuals with normal cervical cytology and those with cervical cancer. Therefore, this single-serum-dilution ELISA should be very useful for assessing the acquired immunity of HPV vaccine recipients. Copyright © 2012 Elsevier B.V. All rights reserved.

  2. Total Effective Xenoestrogen Burden in Serum Samples and Risk for Breast Cancer in a Population-Based Multicase–Control Study in Spain

    Science.gov (United States)

    Pastor-Barriuso, Roberto; Fernández, Mariana F.; Castaño-Vinyals, Gemma; Whelan, Denis; Pérez-Gómez, Beatriz; Llorca, Javier; Villanueva, Cristina M.; Guevara, Marcela; Molina-Molina, José-Manuel; Artacho-Cordón, Francisco; Barriuso-Lapresa, Laura; Tusquets, Ignasi; Dierssen-Sotos, Trinidad; Aragonés, Nuria; Olea, Nicolás; Kogevinas, Manolis; Pollán, Marina

    2016-01-01

    Background: Most studies on endocrine-disrupting chemicals and breast cancer have focused on single compounds and have produced inconclusive findings. Objectives: We assessed the combined estrogenic effects of mixtures of xenoestrogens in serum and their relationship to breast cancer risk. Methods: A total of 186 incident pretreatment breast cancer cases and 196 frequency-matched controls were randomly sampled from a large population-based multicase–control study in Spain. The total effective xenoestrogen burden attributable to organohalogenated xenoestrogens (TEXB-α) and endogenous hormones and more polar xenoestrogens (TEXB-β) was determined in serum samples using high-performance liquid chromatography and E-Screen bioassay. Odds ratios for breast cancer comparing tertiles of serum TEXB-α and TEXB-β were estimated using logistic models, and smooth risk trends were obtained using spline models. Results: Cases had higher geometric mean TEXB-α and TEXB-β levels (8.32 and 9.94 Eeq pM/mL, respectively) than controls (2.99 and 5.96 Eeq pM/mL, respectively). The fully adjusted odds ratios for breast cancer (95% confidence intervals) comparing the second and third tertiles of TEXB-α with the first tertile were 1.77 (0.76, 4.10) and 3.45 (1.50, 7.97), respectively, and those for TEXB-β were 2.35 (1.10, 5.03) and 4.01 (1.88, 8.56), respectively. A steady increase in risk was evident across all detected TEXB-α levels and a sigmoidal trend was observed for TEXB-β. Individual xenoestrogens showed weak and opposing associations with breast cancer risk. Conclusions: This is the first study to show a strong positive association between serum total xenoestrogen burden and breast cancer risk, highlighting the importance of evaluating xenoestrogen mixtures, rather than single compounds, when studying hormone-related cancers. Citation: Pastor-Barriuso R, Fernández MF, Castaño-Vinyals G, Whelan D, Pérez-Gómez B, Llorca J, Villanueva CM, Guevara M, Molina-Molina JM

  3. Evaluation of an immunoassay for human-specific quantitation of therapeutic antibodies in serum samples from non-human primates.

    Science.gov (United States)

    Stubenrauch, Kay; Wessels, Uwe; Lenz, Helmut

    2009-05-01

    Pharmacokinetic characterization of therapeutic antibodies plays an important role during preclinical and clinical development. However, accurate pharmacokinetic evaluation of therapeutic antibodies in serum samples from non-human primates is often complicated by insufficient specificity of the assays to measure drug levels. The present paper describes the use of a murine monoclonal antibody in an immunoassay format to specifically and quantitatively measure human therapeutic antibodies in serum from non-human primates. This murine antibody is directed against a unique epitope on the constant region CH2 domain of all isotypes of human immunoglobulin G (IgG). The antibody, designated anti-human Fcgamma-pan: R10Z8E9, does not cross-react with serum from mouse, rat, and the non-human primates marmoset, rhesus macaque, cynomolgus monkey and baboon when using an enzyme-linked immunosorbent assay (ELISA) or surface plasmon resonance technology (Biacore) format for measurement of the therapeutic antibody. Use of the antibody anti-human Fcgamma-pan: R10Z8E9 as capturing and detection reagent allowed human-specific quantitation of total therapeutic antibody anti-IGF-1R in spiked cynomolgus monkey serum via a Sandwich ELISA format. In contrast, a commercially available polyclonal antibody (PAB) directed to the Fcgamma fragment of human IgG only specifically measured the therapeutic antibody in buffer samples, but not in serum from cynomolgus monkeys. This generic human IgG assay was already applied in several pharmacokinetic studies in cynomolgus monkeys to determine serum levels of different therapeutic antibodies, including the anti-IGF-1R. Validation of the assay for a humanized IgG1 therapeutic antibody against a membrane protein revealed a lower limit of quantitation of 8 ng/mL in undiluted serum. Intra-assay and inter-assay precision was characterized by a coefficient of variation of less than 10% and accuracy was within 15%. Dilutional linearity was evidenced by a

  4. Correlation between glucose concentrations in serum, plasma, and whole blood measured by a point-of-care glucometer and serum glucose concentration measured by an automated biochemical analyzer for canine and feline blood samples.

    Science.gov (United States)

    Tauk, Barbara S; Drobatz, Kenneth J; Wallace, Koranda A; Hess, Rebecka S

    2015-06-15

    To investigate the correlation between glucose concentrations in serum, plasma, and whole blood measured by a point-of-care glucometer (POCG) and serum glucose concentration measured by a biochemical analyzer. Prospective clinical study. 96 blood samples from 80 dogs and 90 blood samples from 65 cats. Serum, plasma, and whole blood were obtained from each blood sample. The glucose concentrations in serum, plasma, and whole blood measured by a POCG were compared with the serum glucose concentration measured by a biochemical analyzer by use of the Lin concordance correlation coefficient (ρc) and Bland-Altman plots. For both canine and feline samples, glucose concentrations in serum and plasma measured by the POCG were more strongly correlated with the serum glucose concentration measured by the biochemical analyzer (ρc, 0.98 for both canine serum and plasma; ρc, 0.99 for both feline serum and plasma) than was that in whole blood (ρc, 0.62 for canine samples; ρc, 0.90 for feline samples). The mean difference between the glucose concentrations determined by the biochemical analyzer and the POCG in serum, plasma, and whole blood was 0.4, 0.3, and 31 mg/dL, respectively, for canine samples and 7, 6, and 32 mg/dL, respectively, for feline samples. Results indicated that use of a POCG to measure glucose concentrations in serum or plasma may increase the accuracy and reliability of diagnostic and treatment decisions associated with glucose homeostasis disorders in dogs and cats.

  5. Heat treatment of serum samples from stray dogs naturally exposed to Dirofilaria immitis and Dirofilaria repens in Romania.

    Science.gov (United States)

    Ciucă, L; Genchi, M; Kramer, L; Mangia, C; Miron, L D; Prete, L Del; Maurelli, M P; Cringoli, G; Rinaldi, L

    2016-07-30

    Pre-heating of serum samples has been shown to reverse false negative antigen tests for Dirofilaria immitis infection in dogs. Here the authors report the results of serum sampling in a population of dogs naturally exposed to D. immitis and Dirofilaria repens infection by testing in ELISA before and after heat treatment. Of 194 dogs sampled from four cities in Romania, D. immitis circulating antigens were found in 16 (8.2%) non heated samples and in 52 (26.8%) heated samples. Of the 108 dogs examined by Knott test, 24 dogs (22.2%) were positive for circulating mf. Subsequent PCR identification showed six dogs had D. immitis mf only, 12 dogs, had only D. repens mf, and 5 were positive for both. Fifty% of dogs with circulating D. immitis mf had positive antigen tests before and after heating, while the other 50% reverted to positive only after heat treatment. Sixty% of dogs with mixed D. immitis/D. repens infection were antigen positive before and after heating, while the other 40% converted to positive after heating. Antigen testing for D. immitis in the 12 dogs with only D. repens mf gave conflicting results. Only two dogs (16%) were antigen negative both before and after heat treatment. Six dogs (50%) became antigen positive after heating and four dogs (30%) were antigen positive both before and after heat treatment. Results would suggest that: false negative result for antigen testing can be reverted by heating of the serum sample; dogs infected with D. repens may have also an occult infection with D. immitis; heat treatment of serum from D. repens-infected dogs can reveal an occult infection with D. immitis. Copyright © 2016 Elsevier B.V. All rights reserved.

  6. Levels of dioxin-like PCBs in low-volume serum samples of male patients attending fertility clinics.

    Science.gov (United States)

    Moltó, Julia; Paul, Raiza; Ortuño, Nuria; Medrano, María Llanos; Aizpurua, Jon; Gómez-Torres, María José

    2016-02-01

    An accurate and easy method for the extraction, cleanup, and HRGC-HRMS analysis of dioxin-like PCBs (DL-PCBs) in low-volume serum samples (1 mL) was developed. Serum samples were extracted several times using n-hexane and purified by acid washing. Recovery rates of labeled congeners ranged from 70 to 110% and the limits of detection were below 1 pg/g on lipid basis. Although human studies are limited and contradictory, several studies have shown that DL-PCBs can have adverse effects on the male reproductive system. In this way, the present method was applied to 21 serum samples of male patients attending fertility clinics. The total levels obtained for the patients ranged from 6.90 to 84.1 pg WHO-TEQ/g lipid, with a mean value of 20.3 pg WHO-TEQ/g lipid. The predominant PCBs (the sum of PCB 118, 156, and 105) contributed 67% to the mean concentration of total DL-PCBs in the samples analyzed.

  7. Correlation of Cadmium and Magnesium in the Blood and Serum Samples of Smokers and Non-Smokers Chronic Leukemia Patients.

    Science.gov (United States)

    Khan, Noman; Afridi, Hasan Imran; Kazi, Tasneem Gul; Arain, Muhammad Balal; Bilal, Muhammad; Akhtar, Asma; Khan, Mustafa

    2017-03-01

    It was studied that cancer-causing processes are related with the disproportions of essential and toxic elements in body tissues and fluid. The purpose of the current study was to evaluate the levels of magnesium (Mg) and cadmium (Cd) in serum and blood samples of smokers and nonsmokers who have chronic myeloid (CML) and lymphocytic (CLL) leukemia, age ranged 31-50 years. For comparative study, age-matched smokers and nonsmoker males were chosen as controls/referents. The levels of elements in patient were analyzed before any treatment by atomic absorption spectrophotometer, after microwave assisted acid digestion. The validation of the method was done by using certified reference materials of serum and blood samples. The resulted data indicated that the adult male smokers and nonsmokers have two- to fourfold higher levels of Cd in the blood and sera samples as compared to the referents (p blood and serum samples of both types of leukemia patients as related to referent values. The resulted data indicates significant negative correlation among Mg and Cd in leukemia patients and smoker referents. Further studies are needed to clarify the role of these elements in pathogenesis of chronic leukemia.

  8. Pre-Analytical Sample Quality : Metabolite Ratios as an Intrinsic Marker for Prolonged Room Temperature Exposure of Serum Samples

    NARCIS (Netherlands)

    Anton, Gabriele; Wilson, Rory; Yu, Zhong-hao; Prehn, Cornelia; Zukunft, Sven; Adamski, Jerzy; Heier, Margit; Meisinger, Christa; Roemisch-Margl, Werner; Wang-Sattler, Rui; Hveem, Kristian; Wolffenbuttel, Bruce; Peters, Annette; Kastenmueller, Gabi; Waldenberger, Melanie

    2015-01-01

    Advances in the "omics" field bring about the need for a high number of good quality samples. Many omics studies take advantage of biobanked samples to meet this need. Most of the laboratory errors occur in the pre-analytical phase. Therefore evidence-based standard operating procedures for the

  9. Diagnostic Value of Galactomannan Antigen Test in Serum and Bronchoalveolar Lavage Fluid Samples from Patients with Nonneutropenic Invasive Pulmonary Aspergillosis.

    Science.gov (United States)

    Zhou, Wei; Li, Hongxing; Zhang, Yan; Huang, Mei; He, Qian; Li, Pei; Zhang, Fang; Shi, Yi; Su, Xin

    2017-07-01

    The objective of this study was to compare the diagnostic value of galactomannan (GM) detection in bronchoalveolar lavage fluid (BALF) and serum samples from nonneutropenic patients with invasive pulmonary aspergillosis (IPA) and determine the optimal BALF GM cutoff value for pulmonary aspergillosis. GM detection in BALF and serum samples was performed by enzyme-linked immunosorbent assay (ELISA) in 128 patients with clinically suspected nonneutropenic pulmonary aspergillosis between June 2014 and June 2016. On the basis of the clinical and pathological diagnoses, 8 patients were excluded because their diagnosis was uncertain. The remaining 120 patients were diagnosed with either IPA ( n = 37), community-acquired pneumonia (CAP; n = 59), noninfectious diseases ( n = 19), or tuberculosis ( n = 5). At a cutoff optical density index (ODI) value of ≥0.5, the sensitivity of BALF GM detection was much higher than that of serum GM detection (75.68% versus 37.84%; P = 0.001), but there was no significant difference between their specificities (80.72% versus 87.14%; P = 0.286). At a cutoff value of ≥1.0, the sensitivity of BALF GM detection was still much higher than that of serum GM detection (64.86% versus 24.32%; P < 0.001), and their specificities were similar (90.36% versus 95.71%; P = 0.202). Receiver operating characteristic (ROC) curve analysis showed that when the BALF GM detection cutoff value was 0.7, its diagnostic value for pulmonary aspergillosis was optimized, and the sensitivity and specificity reached 72.97% and 89.16%, respectively. BALF GM detection was valuable for the diagnosis of IPA in nonneutropenic patients, and its diagnostic value was superior to that of serum GM detection. The optimal BALF GM cutoff value was 0.7. Copyright © 2017 American Society for Microbiology.

  10. Generic anti-drug antibody assay with drug tolerance in serum samples from mice exposed to human antibodies.

    Science.gov (United States)

    Stubenrauch, Kay; Mackeben, Klaus; Vogel, Rudolf; Heinrich, Julia

    2012-11-15

    Knowledge of the anti-drug antibody (ADA) status is necessary in early research studies. Because specific assay materials are sparse and time is pressing, a generic assay format with drug tolerance for detection of ADAs in serum samples from mice exposed to immunoglobulin G (IgG) or antigen-binding fragments (Fabs) is highly desirable. This article describes a generic immune complex assay in the sandwich enzyme-linked immunosorbent assay (ELISA) format based on (i) transformation of free ADAs to immune complexes by preincubation with excess drug, (ii) the use of a murine anti-human Fab constant domain Fab as capture reagent, (iii) detection of the immune complexes by a peroxidase-labeled rabbit anti-murine Fc antibody, and (iv) ADA-positive control conjugates consisting of human Fab and murine IgG. Results of the experiments suggest that the generic immune complex assay for mouse serum samples was at least equivalent to specific ADA immune assays and even superior regarding drug tolerance. The generic immune complex assay confers versatility as it detects ADAs in complex with full-length IgG as well as with Fabs independent of the target specificity in mouse serum samples. These features help to save the sparse amounts of specific antibodies available in early research and development and speed up drug candidate selection. Copyright © 2012 Elsevier Inc. All rights reserved.

  11. Detection of Wuchereria bancrofti DNA in paired serum and urine samples using polymerase chain reaction-based systems

    Directory of Open Access Journals (Sweden)

    Camila Ximenes

    2014-12-01

    Full Text Available The Global Program for the Elimination of Lymphatic Filariasis (GPELF aims to eliminate this disease by the year 2020. However, the development of more specific and sensitive tests is important for the success of the GPELF. The present study aimed to standardise polymerase chain reaction (PCR-based systems for the diagnosis of filariasis in serum and urine. Twenty paired biological urine and serum samples from individuals already known to be positive for Wuchereria bancrofti were collected during the day. Conventional PCR and semi-nested PCR assays were optimised. The detection limit of the technique for purified W. bancrofti DNA extracted from adult worms was 10 fg for the internal systems (WbF/Wb2 and 0.1 fg by using semi-nested PCR. The specificity of the primers was confirmed experimentally by amplification of 1 ng of purified genomic DNA from other species of parasites. Evaluation of the paired urine and serum samples by the semi-nested PCR technique indicated only two of the 20 tested individuals were positive, whereas the simple internal PCR system (WbF/Wb2, which has highly promising performance, revealed that all the patients were positive using both samples. This study successfully demonstrated the possibility of using the PCR technique on urine for the diagnosis of W. bancrofti infection.

  12. Restricted access carbon nanotubes for direct extraction of cadmium from human serum samples followed by atomic absorption spectrometry analysis.

    Science.gov (United States)

    Barbosa, Adriano F; Barbosa, Valéria M P; Bettini, Jefferson; Luccas, Pedro O; Figueiredo, Eduardo C

    2015-01-01

    In this paper, we propose a new sorbent that is able to extract metal ions directly from untreated biological fluids, simultaneously excluding all proteins from these samples. The sorbent was obtained through the modification of carbon nanotubes (CNTs) with an external bovine serum albumin (BSA) layer, resulting in restricted access carbon nanotubes (RACNTs). The BSA layer was fixed through the interconnection between the amine groups of the BSA using glutaraldehyde as cross-linker. When a protein sample is percolated through a cartridge containing RACNTs and the sample pH is higher than the isoelectric point of the proteins, both proteins from the sample and the BSA layer are negatively ionized. Thus, an electrostatic repulsion prevents the interaction between the proteins from the sample on the RACNTs surface. At the same time, metal ions are adsorbed in the CNTs (core) after their passage through the chains of proteins. The Cd(2+) ion was selected for a proof-of-principle case to test the suitability of the RACNTs due to its toxicological relevance. RACNTs were able to extract Cd(2+) and exclude almost 100% of the proteins from the human serum samples in an online solid-phase extraction system coupled with thermospray flame furnace atomic absorption spectrometry. The limits of detection and quantification were 0.24 and 0.80 μg L(-1), respectively. The sampling frequency was 8.6h(-1), and the intra- and inter-day precisions at the 0.80, 15.0, and 30.0 μg L(-1) Cd(2+) levels were all lower than 10.1% (RSD). The recoveries obtained for human blood serum samples fortified with Cd(2+) ranged from 85.0% to 112.0%. The method was successfully applied to analyze Cd(2+) directly from six human blood serum samples without any pretreatment, and the observed concentrations ranged from

  13. Effects of sample treatments on genome recovery via single-cell genomics

    Energy Technology Data Exchange (ETDEWEB)

    Clingenpeel, Scott [USDOE Joint Genome Institute (JGI), Walnut Creek, CA (United States); Schwientek, Patrick [USDOE Joint Genome Institute (JGI), Walnut Creek, CA (United States); Hugenholtz, Philip [Univ. of Queensland, Brisbane (Australia); Woyke, Tanja [USDOE Joint Genome Institute (JGI), Walnut Creek, CA (United States)

    2014-06-13

    It is known that single-cell genomics is a powerful tool for accessing genetic information from uncultivated microorganisms. Methods of handling samples before single-cell genomic amplification may affect the quality of the genomes obtained. Using three bacterial strains we demonstrate that, compared to cryopreservation, lower-quality single-cell genomes are recovered when the sample is preserved in ethanol or if the sample undergoes fluorescence in situ hybridization, while sample preservation in paraformaldehyde renders it completely unsuitable for sequencing.

  14. A comparative study of some physico-chemical properties of human serum albumin samples from different sources--I : Some physico-chemical properties of isoionic human serum albumin solutions

    NARCIS (Netherlands)

    Dröge, J.H.M.; Janssen, L.H.M.; Wilting, J.

    1982-01-01

    Human serum albumin samples from different sources were investigated. The fatty acid content of the albumin before and after deionization on a mixed bed ion-exchange column varied from sample to sample. When an albumin sample from one source was deionized under standard conditions the amount of

  15. Changes in rate serum bioindicators after single or repeated dosages of fipronil

    Science.gov (United States)

    Acute exposure to different classes of pesticides produces different patterns of changes in serum bioindicators (Herr et al., Toxicologist, 2013). We now examined profiles of bioindicators after 1 or 14 treatments with 0, 5, or 10 mg/kg/day fipronil (po). Adult male Long-Evans ra...

  16. Colloidal gold nanoparticle probe-based immunochromatographic assay for the rapid detection of chromium ions in water and serum samples

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Xi; Xiang, Jun-Jian; Tang, Yong; Zhang, Xiao-Li; Fu, Qiang-Qiang; Zou, Jun-Hui; Lin, Yuehe

    2012-09-01

    An immunochromatographic assay (ICA) using gold nanoparticles coated with monoclonal antibody (McAb) for the detection of chromium ions (Cr) in water and serum samples was developed, optimized, and validated. Gold nanoparticles coated with affinity- purified monoclonal antibodies against isothiocyanobenzyl-EDTA (iEDTA)-chelated Cr3+ were used as the detecting reagent in this completive immunoassay-based one- step test strip. The ICA was investigated to measure chromium speciation in water samples. Chromium standard samples of 0-80 ng/mL in water were determined by the test strips. The results showed that the visual lowest detection limit (LDL) of the test strip was 50.0 ng/mL. A portable colorimetric lateral flow reader was used for the quantification of Cr. The results indicated that the linear range of the ICA with colorimetric detection was 5-80 ng/mL. The ICA was also validated for the detection of chromium ions in serum samples. The test trips showed high stability in that they could be stored at at 37 C for at least 12 weeks without significant loss of activity. The test strip also showed good selectivity for Cr detection with negligible interference from other heavy metals. Because of its low cost and short testing time (within 5 min), the test strip is especially suitable for on-site large- scale screening of Cr-polluted water samples, biomonitoring of Cr exposure, and many other field applications.

  17. Levels, profiles and dietary sources of hydroxylated PCBs and hydroxylated and methoxylated PBDEs in Japanese women serum samples.

    Science.gov (United States)

    Haraguchi, Koichi; Ito, Yoshiko; Takagi, Masae; Fujii, Yukiko; Harada, Kouji H; Koizumi, Akio

    2016-12-01

    Human exposure to polychlorinated biphenyls (PCBs) and polybrominated diphenyl ethers (PBDEs) may result in retention of specific congeners of hydroxylated PCBs (OH-PCBs) and hydroxylated/methoxylated PBDEs (OH-/MeO-PBDEs) in serum. However, dietary sources and biotransformation of OH-/MeO-PBDEs in humans are poorly understood. Therefore, this study was conducted to investigate the levels, profiles, and exposure sources of OH-/MeO-PBDEs along with OH-PCBs present in human serum. Twenty serum samples pooled from women of four age groups (30s/40s/50s/60s) living in four districts of Japan were analyzed for OH-/MeO-PBDEs, and their profiles were then compared with those of seafood (seaweed and fish). The major component of OH-PCBs in the phenolic fraction of serum was 4-OH-CB187 (mean: 85pgg -1 wet weight (ww)). Total OH-PCBs accounted for about 1/20 of the total PCBs (mean; 1800pgg -1 ww). In contrast, the predominant component of OH-PBDEs in serum was 6-OH-BDE47 (mean: 183pgg -1 ww), which was about 20-fold higher than BDE-47 (mean; 8.7pgg -1 ww). In the neutral fraction, 2'-MeO-BDE68 was primarily found at a similar concentration (mean 5.6pgg -1 ww) to BDE-47. Both 4-OH-PCB187 and 2'-MeO-BDE68 were significantly correlated with woman's age (pserum were consistent with those in edible seaweeds (Sargassum fusiforme) sold for human consumption, whereas MeO-PBDEs had a similar profile as those in edible fish (Serranidae sp.) from Japanese coastal waters. These findings indicate that the profiles of OH-PBDEs and MeO-PBDEs in Japanese serum are different from those in other countries, and their sources may be specific edible seaweeds and fish, respectively. This is the first report of profiles and dietary sources of OH/MeO-PBDEs in human serum from Japan. Copyright © 2016 Elsevier Ltd. All rights reserved.

  18. A simple and reliable method to blood type monkeys using serum samples.

    Science.gov (United States)

    Chen, Song; Wei, Qing; Li, Junhua; Xiang, Ying; Guo, Hui; Ichim, Thomas E; Chen, Shi; Chen, Gang

    2009-10-01

    Monkeys are frequently used in experimental transplantation research because of their physical traits and availability. As ABO incompatibility may result in humoral injury, it is important to identify the ABO blood typing of monkeys before transplantation. However, monkeys lack expression of ABH antigens on red blood cells, which makes accurate determination of the blood type difficult. The gel agglutination assay has been widely used as a routine blood grouping test clinically for more than 10 years. In this study, we evaluated the efficacy and the interference factors of using the gel system (including the direct gel system and the reverse gel system) for ABO typing in rhesus monkeys (n = 38) and cynomolgus monkeys (n = 26). Immunohistochemistry assay was used to obtain the accurate blood type data of monkeys. The results revealed that the direct gel system was ineffective in blood typing of monkeys, whereas the reverse gel system assay, which is based on preabsorbed serum, provided reproducible results that were confirmed by histologic analysis. We conclude that the reverse gel system assay with use of preabsorbed serum is a simple and reliable method for ABO typing of monkeys.

  19. A Comprehensive Software and Database Management System for Glomerular Filtration Rate Estimation by Radionuclide Plasma Sampling and Serum Creatinine Methods.

    Science.gov (United States)

    Jha, Ashish Kumar

    2015-01-01

    Glomerular filtration rate (GFR) estimation by plasma sampling method is considered as the gold standard. However, this method is not widely used because the complex technique and cumbersome calculations coupled with the lack of availability of user-friendly software. The routinely used Serum Creatinine method (SrCrM) of GFR estimation also requires the use of online calculators which cannot be used without internet access. We have developed user-friendly software "GFR estimation software" which gives the options to estimate GFR by plasma sampling method as well as SrCrM. We have used Microsoft Windows(®) as operating system and Visual Basic 6.0 as the front end and Microsoft Access(®) as database tool to develop this software. We have used Russell's formula for GFR calculation by plasma sampling method. GFR calculations using serum creatinine have been done using MIRD, Cockcroft-Gault method, Schwartz method, and Counahan-Barratt methods. The developed software is performing mathematical calculations correctly and is user-friendly. This software also enables storage and easy retrieval of the raw data, patient's information and calculated GFR for further processing and comparison. This is user-friendly software to calculate the GFR by various plasma sampling method and blood parameter. This software is also a good system for storing the raw and processed data for future analysis.

  20. Use of real-time PCR to process the first galactomannan-positive serum sample in diagnosing invasive aspergillosis.

    Science.gov (United States)

    Millon, Laurence; Piarroux, Renaud; Deconinck, Eric; Bulabois, Claude-Eric; Grenouillet, Frédéric; Rohrlich, Pierre; Costa, Jean-Marc; Bretagne, Stéphane

    2005-10-01

    Positive galactomannan (GM) anti-genemias are included as a microbiological item in the diagnosis of probable or possible invasive aspergillosis (IA). Because false-positive GM results frequently occur, at least two positive results on two different samples are required. Waiting for clinical specimens can delay the initiation of treatment. As an alternative, we wondered whether detection of circulating Aspergillus DNA on the first positive GM serum sample could aid in diagnosing IA. Therefore, we retrospectively screened the first GM-positive serum samples from 29 patients from our hematology unit for Aspergillus DNA using real-time PCR. We compared the real-time PCR results with the final classification of proven, probable, and possible IA according to consensual criteria. No clear correlation between PCR results and the classification with the medical files could be shown. However, a positive PCR result was associated with a poor prognosis (Fisher's test; P=0.01). Our preliminary data suggest that a positive PCR result could indicate a more advanced stage of the disease. Therefore, concomitant positive PCR and GM results may justify the initiation of antifungal therapy in neutropenic patients. In contrast, a negative PCR on the first positive GM sample may argue for postponing costly antifungal administration until additional arguments for the diagnosis of IA are presented.

  1. A Comprehensive Software and Database Management System for Glomerular Filtration Rate Estimation by Radionuclide Plasma Sampling and Serum Creatinine Methods

    International Nuclear Information System (INIS)

    Jha, Ashish Kumar

    2015-01-01

    Glomerular filtration rate (GFR) estimation by plasma sampling method is considered as the gold standard. However, this method is not widely used because the complex technique and cumbersome calculations coupled with the lack of availability of user-friendly software. The routinely used Serum Creatinine method (SrCrM) of GFR estimation also requires the use of online calculators which cannot be used without internet access. We have developed user-friendly software “GFR estimation software” which gives the options to estimate GFR by plasma sampling method as well as SrCrM. We have used Microsoft Windows ® as operating system and Visual Basic 6.0 as the front end and Microsoft Access ® as database tool to develop this software. We have used Russell's formula for GFR calculation by plasma sampling method. GFR calculations using serum creatinine have been done using MIRD, Cockcroft-Gault method, Schwartz method, and Counahan-Barratt methods. The developed software is performing mathematical calculations correctly and is user-friendly. This software also enables storage and easy retrieval of the raw data, patient's information and calculated GFR for further processing and comparison. This is user-friendly software to calculate the GFR by various plasma sampling method and blood parameter. This software is also a good system for storing the raw and processed data for future analysis

  2. Comparing dried and liquid blood serum samples of depressed patients: An analysis by Raman and infrared spectroscopy methods.

    Science.gov (United States)

    Depciuch, J; Parlinska-Wojtan, M

    2018-02-20

    Depression is a serious mental illness. To study the mechanism of depression and search for new, more effective therapies, animal models are often used. Unfortunately, none of the available models reflects all the symptoms of depression. Therefore researchers are looking for new tools to diagnose depression. Unfortunately, the nowadays-available depression diagnosis methods are only psychological tests. However, it is known, that the amount of phospholipids, proteins and lipids decreases during depression. Raman and FTIR (Fourier Transform Infra Red) spectroscopies provide information on the chemical compounds in the measured sample e.g. blood serum. These spectroscopic techniques may thus become reliable and accurate tools for evaluating changes in the amount of phospholipids and proteins in depression disease. In this study differences between dried and liquid blood serum samples of healthy and depressed individuals measured by Raman (range 0-3000cm -1 ) and FTIR (Fourier Transform Infrared) (range 900-3000cm -1 ) spectroscopy were evaluated. The resulting spectra and accurate analysis led to the conclusion that an appropriate measurement of the background and the elimination of peaks from water had the greatest impact on the reliability of the results. Furthermore, after detailed studies of FTIR and Raman spectra of dried and liquid blood serum samples, including a complete analysis of peaks after Kramers-Kröning (KK) transformation, it was found that the sample preparation did not affect the results obtained by Raman spectroscopy. In FTIR measurements only a minimal effect on peak intensity was observed. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Resistin in serum and gingival crevicular fluid as a marker of periodontal inflammation and its correlation with single-nucleotide polymorphism in human resistin gene at −420

    Directory of Open Access Journals (Sweden)

    Swati Pradeep Patel

    2013-01-01

    Full Text Available Aims: Resistin is an adipocytokine, which have been studied for its role in insulin resistance and recently in inflammation. The aim of the present study is to assess the concentration of resistin in serum and gingival crevicular fluid (GCF and to compare the levels between subjects with and without periodontitis and type 2 diabetes mellitus (T2DM and to further correlate the resistin levels with the single-nucleotide polymorphism (SNP at −420. Setting and Designs: A total of 96 subjects (48 males and 48 females were divided on the basis of gingival index (GI, probing pocket depth (PD, clinical attachment level (CAL and hemoglobin A 1c levels into healthy (group 1, n = 24, uncontrolled-diabetes related periodontitis (group 2, n = 24, controlled-diabetes related periodontitis (group 3, n = 24 and chronic periodontitis without T2DM (group 4, n = 24. Materials and Methods: The GCF and serum levels of resistin were quantified using the enzyme-linked immunosorbent assay and compared among the study groups. Further, the association of the resistin levels with periodontal inflammation and SNP at −420 was studied. Results and Conclusion: The resistin levels in GCF and serum from patients with periodontitis or diabetes mellitus related periodontitis (controlled or uncontrolled were higher than that of healthy subjects and correlated positively with GI. Further, subjects with GG genotype at −420 showed significantly higher GI, PD, CAL as compared with genotype group CC. Resistin was detected in all serum and GCF samples and was significantly higher in periodontitis. Further, GG genotype at −420 was associated significantly with periodontal inflammation and resistin levels.

  4. Evaluation of heat-treating heartworm-positive canine serum samples during treatment with Advantage Multi® for Dogs and doxycycline

    OpenAIRE

    Savadelis, Molly D.; Roveto, Jennifer L.; Ohmes, Cameon M.; Hostetler, Joe A.; Settje, Terry L.; Dzimianski, Michael T.; Moorhead, Andrew R.

    2018-01-01

    Background The use of heat-treatment in canine and feline serum has been hypothesized to break the formation of antigen-antibody complexes, thereby freeing the heartworm antigen allowing for detection by commercially available heartworm antigen kits. While studies have analyzed the effect of heat-treating serum and plasma samples in the detection of heartworm antigen, these studies have not utilized necropsy verified results for validation. This study evaluated the use of heat-treating serum ...

  5. Proteomic profiling of nephrotic syndrome in serum using magnetic bead based sample fractionation & MALDI-TOF MS

    Science.gov (United States)

    Sui, Weiguo; Dai, Yong; Zhang, Yue; Chen, Jiejing; Liu, Huaying; Huang, He

    2012-01-01

    Background & objectives: At present, the diagnosis of nephrotic syndrome (NS) requires a renal biopsy which is an invasive procedure. We undertook this pilot study to develop an alternative method and potential new biomarkers for diagnosis, and validated a set of well-integrated tools called ClinProt to investigate serum petidome in NS patients. Methods: The fasting blood samples from 49 patients diagnosed with NS by renal biopsy, including 17 mesangial proliferative glomerulonephritis (MsPGN), 12 minimal change nephrotic syndrome (MCNS), 10 focal segmental glomerulosclerosis (FSGS) and 10 membranous nephropathy (MN), were collected and screened to describe their variability of the serum peptidome. The results in NS group were compared with those in 10 control healthy individuals. Specimens were purified with magnetic beads-based weak cation exchange chromatography and analyzed in a MALDI-TOF MS. Results: The results showed 43, 61, 45 and 19 differential peptide peaks in MsPGN, MCNS, MN and FSGS groups, respectively. A Genetic Algorithm was used to set up the classification models. Cross validation of healthy controls from MsPGN, MCNS, MN and FSGS was 96.18, 100, 98.53 and 94.12 per cent, respectively. The recognition capabilities were 100 per cent. Interpretation & conclusions: Our results showed that proteomic analysis of serum with MALDI-TOF MS is a fast and reproducible approach, which may give an early idea of the pathology of nephrotic syndrome. PMID:22561615

  6. Standard Specification for Sampling Single-Phase Geothermal Liquid or Steam for Purposes of Chemical Analysis

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1983-01-01

    1.1 This specification covers the basic requirements for equipment to be used for the collection of uncontaminated and representative samples from single-phase geothermal liquid or steam. Geopressured liquids are included. See Fig 1.

  7. Determination of some psychotropic drugs in serum and saliva samples by HPLC-DAD and HPLC MS.

    Science.gov (United States)

    Petruczynik, A; Wróblewski, K; Szultka-Młyńska, M; Buszewski, B; Karakuła-Juchnowicz, H; Gajewski, J; Morylowska-Topolska, J; Waksmundzka-Hajnos, M

    2016-08-05

    A simple, rapid and sensitive HPLC-DAD method has been developed and validated for the simultaneous determination of seven psychotropic drugs (risperidone, citalopram, clozapine,quetiapine, levomepromazine, perazine and aripiprazole) in human serum or saliva samples. The chromatographic analyses were performed on a XSELECT CSH Phenyl-Hexyl column with a mobile phase containing methanol, acetate buffer at pH 3.5 and 0.025mL(-1) diethylamine. The influence of concentration of methanol in injection samples and injection volume on peak symmetry and system efficiency was examined.The full separation of all investigated drugs, good peaks' symmetry and simultaneously high systems efficiency were obtained in applied chromatographic system. The method is suitable for the analysis of investigated drugs in human plasma or saliva for psychiatric patients for control of pharmacotherapy, particularly in combination therapy. HPLC-MS was applied for verification of the presence of drugs and their metabolites in serum and saliva samples from patients. Copyright © 2016 Elsevier B.V. All rights reserved.

  8. Serum Chrome levels sampled with steel needle vs. plastic IV cannula

    DEFF Research Database (Denmark)

    Penny, Jeannette Østergaard; Overgaard, Søren

    2010-01-01

      Modern Metal-on-metal (MoM) joint articulations releases metal ions to the body. Research tries to establish how much this elevates metal ion levels and whether it causes adverse effects. The steel needle that samples the blood may introduce additional chromium to the sample thereby causing bia...

  9. Changes in alt, ast and alp values of plasma and serum samples ...

    African Journals Online (AJOL)

    Blood samples were obtained from a total of 20 patients that presented with cases of liver malfunction at the Ebonyi State University Teaching Hospital, Abakaliki, Nigeria. The enzyme assays were carried out immediately upon sample collection and separation to obtain the baseline value (BV), and thereafter at specified ...

  10. Development and Validation of HPLC Method for Determination of Crocetin, a constituent of Saffron, in Human Serum Samples

    Directory of Open Access Journals (Sweden)

    Amir Hooshang Mohammadpour

    2013-01-01

    Full Text Available Objective(s:The present study reports the development and validation of a sensitive and rapid extraction method beside high performance liquid chromatographic method for the determination of crocetin in human serum. Materials and Methods:The HPLC method was carried out by using a C18 reversed-phase column and a mobile phase composed of methanol/water/acetic acid (85:14.5:0.5 v/v/v at the flow rate of 0.8 ml/min. The UV detector was set at 423 nm and 13-cis retinoic acid was used as the internal standard. Serum samples were pretreated with solid-phase extraction using Bond Elut C18 (200mg cartridges or with direct precipitation using acetonitrile. Results:The calibration curves were linear over the range of 0.05-1.25 µg/ml for direct precipitation method and 0.5-5 µg/ml for solid-phase extraction. The mean recoveries of crocetin over a concentration range of 0.05-5 µg/ml serum for direct precipitation method and 0.5-5 µg/ml for solid-phase extraction were above 70 % and 60 %, respectively. The intraday coefficients of variation were 0.37- 2.6% for direct precipitation method and 0.64 - 5.43% for solid-phase extraction. The inter day coefficients of variation were 1.69 – 6.03% for direct precipitation method and 5.13-12.74% for solid-phase extraction, respectively. The lower limit of quantification for crocetin was 0.05 µg/ml for direct precipitation method and 0.5 µg/ml for solid-phase extraction. Conclusion: The validated direct precipitation method for HPLC satisfied all of the criteria that were necessary for a bioanalytical method and could reliably quantitate crocetin in human serum for future clinical pharmacokinetic study

  11. Optimal sampling strategies to assess inulin clearance in children by the inulin single-injection method

    NARCIS (Netherlands)

    van Rossum, Lyonne K.; Mathot, Ron A. A.; Cransberg, Karlien; Vulto, Arnold G.

    2003-01-01

    Glomerular filtration rate in patients can be determined by estimating the plasma clearance of inulin with the single-injection method. In this method, a single bolus injection of inulin is administered and several blood samples are collected. For practical and convenient application of this method

  12. Elevated serum triglycerides is the strongest single indicator for the presence of metabolic syndrome in patients with type 2 diabetes

    Directory of Open Access Journals (Sweden)

    Dimou Eleni

    2006-10-01

    Full Text Available Abstract Background Patients with diabetes already fulfill one diagnostic criterion for MS according to the existing classifications. Our aim was to identify one single clinical parameter, which could effectively predict the presence of MS in patients with type 2 diabetes. Methods We studied all patients with type 2 diabetes who attended our Diabetes Outpatient Clinic during a three-month period. Waist circumference, blood pressure and serum lipids were measured. Establishment of MS diagnosis was based a on National Cholesterol Education Program Adult Treatment Panel III (NCEP ATP III criteria and b on International Diabetes Federation (IDF criteria. Receiver operating characteristic (ROC analysis was applied in order to identify the clinical parameter with the highest predictive capability for MS. Among the 500 participating patients (231 males, 269 females, MS was diagnosed in 364 patients (72.8% according to the NCEP ATP III criteria and in 408 patients (81.6% according to the IDF criteria. Results For the NCEP ATP III classification, serum triglycerides (in the overall population, waist and HDL (in female population demonstrated the highest predictive capability for MS (AUCs:0.786, 0.805 and 0.801, respectively. For the IDF classification, no single parameter reached an AUC > 0.800 in the overall population. In females, HDL displayed a satisfactory predictive capability for MS with an AUC which was significantly higher than the one in males (0.785 vs. 0.676, respectively, p Conclusion Elevated serum triglycerides strongly indicate the presence of MS in patients with type 2 diabetes. In female patients with type 2 diabetes, central obesity was the second stronger predictor of MS besides hypertriglyceridemia.

  13. Development of a voltammetric assay, using screen-printed electrodes, for clonazepam and its application to beverage and serum samples.

    Science.gov (United States)

    Honeychurch, Kevin C; Brooks, Joshua; Hart, John P

    2016-01-15

    This paper describes the development of an electrochemical assay based on screen-printed carbon sensors for the determination of clonazepam in serum and in wine. The cyclic voltammetric behaviour of the drug was investigated and the effects of pH and scan rate on the peak current and peak potential determined. Two reduction peaks were recorded on the initial negative going scan, which were considered to result from the 2e(-), 2 H(+) reduction of the 4,5-azomethine and from the 4e(-), 4 H(+) reduction of the 7-NO2 to a hydroxylamine. On the return positive going scan an oxidation peak was seen, which was considered to result from the 2e(-), 2 H(+) oxidation (O1) of the hydroxylamine to the corresponding nitroso species. At pH 11 the solution of clonazepam was found to turn from clear to yellow in colour and the voltammetric signal of the O1 oxidation process was found to be adsorptive in nature, this was exploited in the development of an adsorptive stripping voltammetric assay. Experimental conditions were then optimised for the differential pulse adsorptive voltammetric measurement of clonazepam in wine and serum samples. It was shown that these analyses could be performed on only 100µL of sample which was deposited on the sensor surface. Mean recoveries of 79.53% (%CV=9.88%) and 88.22% (%CV=14.1%) were calculated for wine fortified with 3.16µg/mL and serum fortified with 12.6µg/mL. Copyright © 2015 Elsevier B.V. All rights reserved.

  14. A novel colorimetric method based on copper nanoclusters with intrinsic peroxidase-like for detecting xanthine in serum samples

    Science.gov (United States)

    Yan, Zhengyu; Niu, Qianqian; Mou, Mingyao; Wu, Yi; Liu, Xiaoxuan; Liao, Shenghua

    2017-07-01

    A facile strategy for detecting xanthine in serum samples by copper nanocluster (CuNCs) with high intrinsic peroxidase-like activity was reported. Firstly, a simple, mild and time-saving method for preparing CuNCs was developed, in which dithiothreitol (DTT) and bovine serum albumin (BSA) were used as reductant and stabilizer, respectively. The as-prepared CuNCs exhibited a fluorescence emission at 590 nm with a quantum yield (QY) of approximately 5.29%, the fluorescence intensity of the as-prepared CuNCs exhibited no considerable change when stored under ambient condition with the lifetime is 1.75 μs. Moreover, the as-prepared CuNCs exhibited high intrinsic peroxidase-like activity with lower K m ( K m = 8.90 × 10-6 mol L-1) for H2O2, which indicated that CuNCs have a higher affinity for H2O2. Compared with natural enzyme, the as-synthesized CuNCs are more catalytic stable over a wide range of pH (4.0 13.0) and temperature (4 80 °C). Finally, an indirect method for sensing xanthine was established because xanthine oxidase can catalyse the oxidation of xanthine to produce H2O2. Xanthine could be detected as low as 3.8 × 10-7 mol L-1 with a linear range from 5.0 × 10-7 to 1.0 × 10-4 mol L-1. These results proved that the proposed method is sensitive and accurate and could be successfully applied to the determination of xanthine in the serum sample with satisfaction.

  15. An enzyme immunoassay for determining epidermal growth factor (EGF) in human serum samples using an ultramicroanalytical system.

    Science.gov (United States)

    Castells Martínez, Elisa María; Del Valle, Ruben; González, Ernesto Carlos; Melchor, Antonio; Pérez, Pedro Lucio; González, Idania; Carr, Adriana; León, Kalet

    2017-01-01

    Human epidermal growth factor is a small peptide consisting of 53 amino acid residues, which stimulates cell proliferation and is associated with several human carcinomas. A simple sandwich-type ultramicroELISA assay (UMELISA), based on the advantages of high affinity reaction between streptavidin and biotin has been developed for the measurement of EGF in human serum samples. Strips coated with a high affinity monoclonal antibody directed against EGF are used as solid phase, to ensure the specificity of the assay. The EGF assay was completed in 18 hr, with a measuring range of 39-2500 pg/mL. The intra- and inter-assay coefficients of variation were 4.4-7.3% and 0-5.1%, respectively, depending on the EGF concentrations evaluated. Percentage recovery ranged from 96-104%. Regression analysis showed a good correlation with the commercially available Human EGF Immunoassay Quantikine ® ELISA kit (n = 130, r = 0.92, P characteristics of our UMELISA EGF endorse its use for the quantification of EGF in human serum samples.

  16. Quantitative evaluation of dental anxiety indicators in the serum and saliva samples of children treated under general anesthesia.

    Science.gov (United States)

    Yıldırım, Sinem; Bakkal, Meltem; Bulut, Huri; Selek, Sahabettin

    2018-01-21

    Dental anxiety level has been previously associated with oral health status. Since general anesthesia (GA) allows dental treatments to be performed in anxious children with a high number of caries, we aimed to evaluate the dental anxiety levels of these children before and after dental treatments performed under GA. Thirty-eight children with high anxiety aged between 35 and 72 months who required multiple dental treatments to be performed under GA were included in the study. Frankl's Behavior Rating Scale, sitting patterns, Facial Image Scale, and Children's Fear Survey Schedule-Dental Subscale (completed by the children's parents) were recorded before and after the dental treatments performed under GA. Pre-treatment and post-treatment biochemical parameters, including cortisol, alpha-amylase, and chromogranin A levels, in saliva and serum samples were also evaluated. The psychometric scales showed a statistically significant reduction in the post-treatment dental anxiety levels of the children compared with the pre-treatment anxiety levels. Additionally, the biochemical parameters measured in the serum and whole saliva samples showed a decrease after treatments performed under GA. Our study results suggest that performing dental treatments under GA can reduce the dental anxiety levels of children with a high number of caries.

  17. Analysis of U and Pu resin bead samples with a single stage mass spectrometer

    International Nuclear Information System (INIS)

    Smith, D.H.; Walker, R.L.; Bertram, L.K.; Carter, J.A.

    1979-01-01

    Resin bead sampling enables the shipment of nanogram U and Pu quantities for analysis. Application of this sampling technique to safeguards was investigated with a single-stage mass spectrometer. Standards gave results in good agreement with NBS certified values. External precisions of +-0.5% were obtained on isotopic ratios of approx. 0.01; precisions on quantitative measurements are +-1.0%

  18. Analysis of multiple single nucleotide polymorphisms (SNP) on DNA traces from plasma and dried blood samples

    NARCIS (Netherlands)

    Catsburg, Arnold; van der Zwet, Wil C.; Morre, Servaas A.; Ouburg, Sander; Vandenbroucke-Grauls, Christina M. J. E.; Savelkoul, Paul H. M.

    2007-01-01

    Reliable analysis of single nucleotide polymorphisms (SNPs) in DNA derived from samples containing low numbers of cells or from suboptimal sources can be difficult. A new procedure to characterize multiple SNPs in traces of DNA from plasma and old dried blood samples was developed. Six SNPs in the

  19. Quantitative Single-letter Sequencing: a method for simultaneously monitoring numerous known allelic variants in single DNA samples

    Directory of Open Access Journals (Sweden)

    Duborjal Hervé

    2008-02-01

    Full Text Available Abstract Background Pathogens such as fungi, bacteria and especially viruses, are highly variable even within an individual host, intensifying the difficulty of distinguishing and accurately quantifying numerous allelic variants co-existing in a single nucleic acid sample. The majority of currently available techniques are based on real-time PCR or primer extension and often require multiplexing adjustments that impose a practical limitation of the number of alleles that can be monitored simultaneously at a single locus. Results Here, we describe a novel method that allows the simultaneous quantification of numerous allelic variants in a single reaction tube and without multiplexing. Quantitative Single-letter Sequencing (QSS begins with a single PCR amplification step using a pair of primers flanking the polymorphic region of interest. Next, PCR products are submitted to single-letter sequencing with a fluorescently-labelled primer located upstream of the polymorphic region. The resulting monochromatic electropherogram shows numerous specific diagnostic peaks, attributable to specific variants, signifying their presence/absence in the DNA sample. Moreover, peak fluorescence can be quantified and used to estimate the frequency of the corresponding variant in the DNA population. Using engineered allelic markers in the genome of Cauliflower mosaic virus, we reliably monitored six different viral genotypes in DNA extracted from infected plants. Evaluation of the intrinsic variance of this method, as applied to both artificial plasmid DNA mixes and viral genome populations, demonstrates that QSS is a robust and reliable method of detection and quantification for variants with a relative frequency of between 0.05 and 1. Conclusion This simple method is easily transferable to many other biological systems and questions, including those involving high throughput analysis, and can be performed in any laboratory since it does not require specialized

  20. Sample dilution : A methodological pitfall in the measurement of tissue but not serum ACE-activity

    NARCIS (Netherlands)

    Koiter, J; Navis, G; de Jong, PE; van Gilst, WH; de Zeeuw, D

    Many tissue ACE-assays suffer from underestimation of the ACE-activity at low sample dilutions. However, measurement of ACE-activity as the amount of hippuric acid produced by cleavage of the commonly used substrate hippuryl-histidyl-leucine might circumvent this problem. In this study, we

  1. Surface chemical approach to single-step measurement of antibody in human serum using localized surface plasmon resonance biosensor on microtiter plate system.

    Science.gov (United States)

    Yamamichi, Junta; Ojima, Tetsunori; Iida, Mie; Yurugi, Kimiko; Imamura, Takeshi; Ashihara, Eishi; Kimura, Shinya; Maekawa, Taira

    2014-07-01

    In clinical settings, serum antibody levels serve as markers of pathology. For example, antibodies related to autoimmune diseases are among the conventional targets in laboratory tests. Simple clinical tests can improve the efficacy of laboratory practice. This study describes a single-step, wash-free technique for optically detecting antibodies in human serum through the localized surface plasmon resonance (LSPR) of gold nanoparticles. As a proof-of-concept experiment, the amount of antibiotin dissolved in human serum was measured with a LSPR-based biosensor in a wash-free manner using a conventional 96-well microtiter plate and a plate reader. For an efficient surface modification of biosensors, zwitterionic copolymer was used as a scaffold on the gold nanoparticle surface to immobilize antigen and blocking reagent. Single-step, wash-free measurement of antibiotin in human serum was successfully achieved. In addition, nonspecific responses from serum contents were significantly reduced because both the copolymer and hydrophilic antigen reagent that we employed were composed of poly(ethylene oxide) spacer. Comparative experiments of the antigen-antibody reaction in serum to that in buffered solution revealed that serum is a favorable environment for the biological reaction. In conclusion, our gold-nanoparticle-based LSPR method may provide a rapid and simple way to measure the amount of antibody in serum quantitatively in clinical practice.

  2. Detection of antibodies to the 97 kDa component of Toxoplasma gondii in samples of human serum

    Directory of Open Access Journals (Sweden)

    Ribeiro Alessandra Carla de Almeida

    2002-01-01

    Full Text Available This study was carried out to investigate the immune response against 97 kDa (p97 molecular marker of Toxoplasma gondii that has been characterized as a cytosolic protein and a component of the excreted-secreted antigens from this parasite. A total of 60 serum samples from patients were analyzed by enzime-linked immunosorbent assay and Western blot for toxoplasmosis. These samples were organized in three groups, based on clinical symptoms and results of serological tests. Group I: 20 samples reactive to IgG and IgM (acute phase; group II: 20 non-reactive samples (control group; and group III: 20 samples reactive only to IgG (chronic phase. Western blot was performed with total antigenic extracts or with excreted and secreted antigen from T. gondii to identify the fraction correspondent to p97. It was observed that this cytosolic component from T. gondii stimulates the immunologic system to produce both IgM and IgG antibodies in the beginning of the acute infection and IgG throughout the chronic stage of the asymptomatic toxoplasmosis.

  3. Comprehensive metabolic characterization of serum osteocalcin action in a large non-diabetic sample

    DEFF Research Database (Denmark)

    Entenmann, Lukas; Pietzner, Maik; Artati, Anna

    2017-01-01

    Recent research suggested a metabolic implication of osteocalcin (OCN) in e.g. insulin sensitivity or steroid production. We used an untargeted metabolomics approach by analyzing plasma and urine samples of 931 participants using mass spectrometry to reveal further metabolic actions of OCN. Sever...... study provides a read-out of metabolic actions of OCN. However, most of the associations were weak arguing for a limited role of OCN in whole-body metabolism....

  4. New method for simultaneous determination of 55Fe and 59Fe in blood serum samples

    International Nuclear Information System (INIS)

    Saukkonen, H.; Uhlenius, R.

    1978-01-01

    Routine methods for the measurement of 55 Fe and 59 Fe activities in biological samples are frequently required in metabolic studies of iron. A new simple method for the simultaneous determination of 59 Fe and 55 Fe concentration in 5 cm 3 samples of blood is described and carefully evaluated. Before the measurement of the activity, organic matter was eliminated by HNO 3 -HClO 4 wet ashing and iron was electroplated onto a copper plate. The accuracy of results was studied by assessing samples, which contained known amounts of radioactivity and determining the counts per nanocurie in each case. The accuracy of the results of 59 Fe and 55 Fe determinations was found to be about 5%. The method has been routinely used to determine iron resorption in patients using the double isotope method. The determination proved to be satisfactory and not too laborious. When performing the yield determination there is a way of detecting and correcting mistakes or incompleteness in different stages of the measurement, thus leading to a high degree of reliability. (T.G.)

  5. Detection of Merkel Cell Polyomavirus DNA in Serum Samples of Healthy Blood Donors

    Directory of Open Access Journals (Sweden)

    Elisa Mazzoni

    2017-11-01

    Full Text Available Merkel cell polyomavirus (MCPyV has been detected in 80% of Merkel cell carcinomas (MCC. In the host, the MCPyV reservoir remains elusive. MCPyV DNA sequences were revealed in blood donor buffy coats. In this study, MCPyV DNA sequences were investigated in the sera (n = 190 of healthy blood donors. Two MCPyV DNA sequences, coding for the viral oncoprotein large T antigen (LT, were investigated using polymerase chain reaction (PCR methods and DNA sequencing. Circulating MCPyV sequences were detected in sera with a prevalence of 2.6% (5/190, at low-DNA viral load, which is in the range of 1–4 and 1–5 copies/μl by real-time PCR and droplet digital PCR, respectively. DNA sequencing carried out in the five MCPyV-positive samples indicated that the two MCPyV LT sequences which were analyzed belong to the MKL-1 strain. Circulating MCPyV LT sequences are present in blood donor sera. MCPyV-positive samples from blood donors could represent a potential vehicle for MCPyV infection in receivers, whereas an increase in viral load may occur with multiple blood transfusions. In certain patient conditions, such as immune-depression/suppression, additional disease or old age, transfusion of MCPyV-positive samples could be an additional risk factor for MCC onset.

  6. A study of single nucleotide polymorphism of leptin gene effect on serum copper, zinc and iron concentrations in Czech Pied bulls

    Directory of Open Access Journals (Sweden)

    Aleš Pavlík

    2013-01-01

    Full Text Available Leptin, the product of the ob gene, is secreted mainly in adipose tissue. Due to the associations between plasma leptin concentrations and body fat, leptin could be used as an indicator for the in vivo evaluation of carcass composition in breeding programs. Previous studies showed relation between leptin concentrations and some trace elements, suggesting that they might be mediators of leptin production. The present study was designed to evaluate the effect of single nucleotide polymorphism of the leptin gene on concentration of trace elements in the serum of 58 Czech Pied bulls. Three experimental groups of bulls were formed depending on different leptin genotypes: group CC (n = 28, group CT (n = 21 and group TT (n = 9. In all groups, the age (at a mean age of 240 days and the body weight (mean 291 ± 11 kg difference among the chosen animals was non-significant. Blood samples of all bulls in experimental groups were collected from vena jugularis externa between 8.00 and 9.30 h. Concentrations of copper, zinc and iron in the serum of animals were measured. Significantly lower (P TT group (13.21 ± 1.81 µmol·l-1 compared to CC (20.09 ± 1.11 µmol·l-1 and CT group (19.67 ± 1.45 µmol·l-1. In case of copper and iron concentrations in serum of animals, no differences were recorded between the tested groups. This is the first study of its kind in Czech Pied cattle. Based on our results, we may assume that zinc plays some role in the metabolism of adipose tissue, havings an effect on beef quality.

  7. Proteomic profiling of renal allograft rejection in serum using magnetic bead-based sample fractionation and MALDI-TOF MS.

    Science.gov (United States)

    Sui, Weiguo; Huang, Liling; Dai, Yong; Chen, Jiejing; Yan, Qiang; Huang, He

    2010-12-01

    Proteomics is one of the emerging techniques for biomarker discovery. Biomarkers can be used for early noninvasive diagnosis and prognosis of diseases and treatment efficacy evaluation. In the present study, the well-established research systems of ClinProt Micro solution incorporated unique magnetic bead sample preparation technology, which, based on matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS), have become very successful in bioinformatics due to its outstanding performance and reproducibility for discovery disease-related biomarker. We collected fasting blood samples from patients with biopsy-confirmed acute renal allograft rejection (n = 12), chronic rejection (n = 12), stable graft function (n = 12) and also from healthy volunteers (n = 13) to study serum peptidome patterns. Specimens were purified with magnetic bead-based weak cation exchange chromatography and analyzed with a MALDI-TOF mass spectrometer. The results indicated that 18 differential peptide peaks were selected as potential biomarkers of acute renal allograft rejection, and 6 differential peptide peaks were selected as potential biomarkers of chronic rejection. A Quick Classifier Algorithm was used to set up the classification models for acute and chronic renal allograft rejection. The algorithm models recognize 82.64% of acute rejection and 98.96% of chronic rejection episodes, respectively. We were able to identify serum protein fingerprints in small sample sizes of recipients with renal allograft rejection and establish the models for diagnosis of renal allograft rejection. This preliminary study demonstrated that proteomics is an emerging tool for early diagnosis of renal allograft rejection and helps us to better understand the pathogenesis of disease process.

  8. Chemiluminescence lateral flow immunoassay cartridge with integrated amorphous silicon photosensors array for human serum albumin detection in urine samples.

    Science.gov (United States)

    Zangheri, Martina; Di Nardo, Fabio; Mirasoli, Mara; Anfossi, Laura; Nascetti, Augusto; Caputo, Domenico; De Cesare, Giampiero; Guardigli, Massimo; Baggiani, Claudio; Roda, Aldo

    2016-12-01

    A novel and disposable cartridge for chemiluminescent (CL)-lateral flow immunoassay (LFIA) with integrated amorphous silicon (a-Si:H) photosensors array was developed and applied to quantitatively detect human serum albumin (HSA) in urine samples. The presented analytical method is based on an indirect competitive immunoassay using horseradish peroxidase (HRP) as a tracer, which is detected by adding the luminol/enhancer/hydrogen peroxide CL cocktail. The system comprises an array of a-Si:H photosensors deposited on a glass substrate, on which a PDMS cartridge that houses the LFIA strip and the reagents necessary for the CL immunoassay was optically coupled to obtain an integrated analytical device controlled by a portable read-out electronics. The method is simple and fast with a detection limit of 2.5 mg L -1 for HSA in urine and a dynamic range up to 850 mg L -1 , which is suitable for measuring physiological levels of HSA in urine samples and their variation in different diseases (micro- and macroalbuminuria). The use of CL detection allowed accurate and objective analyte quantification in a dynamic range that extends from femtomoles to picomoles. The analytical performances of this integrated device were found to be comparable with those obtained using a charge-coupled device (CCD) as a reference off-chip detector. These results demonstrate that integrating the a-Si:H photosensors array with CL-LFIA technique provides compact, sensitive and low-cost systems for CL-based bioassays with a wide range of applications for in-field and point-of-care bioanalyses. Graphical Abstract A novel integrated portable device was developed for direct quantitative detection of human serum albumin (HSA) in urine samples, exploiting a chemiluminescence lateral flow immunoassay (LFIA). The device comprises a cartridge that holds the LFIA strip and all the reagents necessary for the analysis, an array of amorphous silicon photosensors, and a custom read-out electronics.

  9. Comparison of diagnostic methods to detect Histoplasma capsulatum in serum and blood samples from AIDS patients

    Science.gov (United States)

    da Silva, Marcos Vinicius; Criado, Paulo Ricardo; Luiz, Olinda do Carmo; Vicentini, Adriana Pardini

    2018-01-01

    Background Although early and rapid detection of histoplasmosis is essential to prevent morbidity and mortality, few diagnostic tools are available in resource-limited areas, especially where it is endemic and HIV/AIDS is also epidemic. Thus, we compared conventional and molecular methods to detect Histoplasma capsulatum in sera and blood from HIV/AIDS patients. Methodology We collected a total of 40 samples from control volunteers and patients suspected of histoplasmosis, some of whom were also infected with other pathogens. Samples were then analyzed by mycological, serological, and molecular methods, and stratified as histoplasmostic with (group I) or without AIDS (group II), uninfected (group III), and infected with HIV and other pathogens only (group IV). All patients were receiving treatment for histoplasmosis and other infections at the time of sample collection. Results Comparison of conventional methods with nested PCR using primers against H. capsulatum 18S rRNA (HC18S), 5.8S rRNA ITS (HC5.8S-ITS), and a 100 kDa protein (HC100) revealed that sensitivity against sera was highest for PCR with HC5.8S-ITS, followed by immunoblotting, double immunodiffusion, PCR with HC18S, and PCR with HC100. Specificity was equally high for double immunodiffusion, immunoblotting and PCR with HC100, followed for PCR with HC18S and HC5.8-ITS. Against blood, sensitivity was highest for PCR with HC5.8S-ITS, followed by PCR with HC18S, Giemsa staining, and PCR with HC100. Specificity was highest for Giemsa staining and PCR with HC100, followed by PCR with HC18S and HC5.8S-ITS. PCR was less efficient in patients with immunodeficiency due to HIV/AIDS and/or related diseases. Conclusion Molecular techniques may detect histoplasmosis even in cases with negative serology and mycology, potentially enabling early diagnosis. PMID:29342162

  10. Comparison of diagnostic methods to detect Histoplasma capsulatum in serum and blood samples from AIDS patients.

    Directory of Open Access Journals (Sweden)

    Katia Cristina Dantas

    Full Text Available Although early and rapid detection of histoplasmosis is essential to prevent morbidity and mortality, few diagnostic tools are available in resource-limited areas, especially where it is endemic and HIV/AIDS is also epidemic. Thus, we compared conventional and molecular methods to detect Histoplasma capsulatum in sera and blood from HIV/AIDS patients.We collected a total of 40 samples from control volunteers and patients suspected of histoplasmosis, some of whom were also infected with other pathogens. Samples were then analyzed by mycological, serological, and molecular methods, and stratified as histoplasmostic with (group I or without AIDS (group II, uninfected (group III, and infected with HIV and other pathogens only (group IV. All patients were receiving treatment for histoplasmosis and other infections at the time of sample collection.Comparison of conventional methods with nested PCR using primers against H. capsulatum 18S rRNA (HC18S, 5.8S rRNA ITS (HC5.8S-ITS, and a 100 kDa protein (HC100 revealed that sensitivity against sera was highest for PCR with HC5.8S-ITS, followed by immunoblotting, double immunodiffusion, PCR with HC18S, and PCR with HC100. Specificity was equally high for double immunodiffusion, immunoblotting and PCR with HC100, followed for PCR with HC18S and HC5.8-ITS. Against blood, sensitivity was highest for PCR with HC5.8S-ITS, followed by PCR with HC18S, Giemsa staining, and PCR with HC100. Specificity was highest for Giemsa staining and PCR with HC100, followed by PCR with HC18S and HC5.8S-ITS. PCR was less efficient in patients with immunodeficiency due to HIV/AIDS and/or related diseases.Molecular techniques may detect histoplasmosis even in cases with negative serology and mycology, potentially enabling early diagnosis.

  11. Common epitopes in LPS of different Enterobacteriaceae are associated with an immune response against Escherichia coli O157 in bovine serum samples.

    Science.gov (United States)

    Navarro, Armando; Eslava, Carlos; García de la Torre, Guadalupe; León, Luis Antonio; Licona, Delia; León, Lemuel; Zarco, Luis Alberto; Cravioto, Alejandro

    2007-11-01

    Epidemiological studies in both humans and animals conducted in Mexico have shown that the isolation frequency of Escherichia coli O157 : H7 is low. In a previous study, IgG antibodies against E. coli O157, O7 and O116 LPS were found in serum samples from children and adults with no previous history of E. coli O157 : H7 infection. The present study was designed to determine whether a similar immune response against E. coli O157 : H7 and other antigenically related bacteria was present in bovine serum samples. A total of 310 serum samples from different herds in Mexico was analysed by microagglutination assays against different enterobacterial antigens, including E. coli O157. Microagglutination assays were positive against E. coli O7 (55 %), O116 (76 %) and O157 (36 %), Escherichia hermannii (15 %), Salmonella enterica serotype Urbana (14 %) and Salmonella enterica subsp. arizonae (40 %). These results were confirmed using a specific ELISA with purified LPS. A positive reaction was observed against the LPS of E. coli O7 (29 %), O116 (12 %) and O157 (22 %), E. hermannii (4 %), Salmonella Urbana (13 %) and S. enterica subsp. arizonae (12 %). Serum absorption studies of positive serum samples indicated the existence of at least three common epitopes shared by the LPS of E. coli O7, O116 and O157, and two others between E. coli O157 and Salmonella Urbana and S. enterica subsp. arizonae. A bactericidal assay against E. coli O157 : H7 using 31 bovine serum samples was performed, and 22 (71 %) of these serum samples gave positive results. The data demonstrated that bovine serum showed a response against different enterobacteria, including E. coli O157, and that this response could be due to the presence of shared epitopes in the LPS of these organisms.

  12. Comparison of Single-Point and Continuous Sampling Methods for Estimating Residential Indoor Temperature and Humidity.

    Science.gov (United States)

    Johnston, James D; Magnusson, Brianna M; Eggett, Dennis; Collingwood, Scott C; Bernhardt, Scott A

    2015-01-01

    Residential temperature and humidity are associated with multiple health effects. Studies commonly use single-point measures to estimate indoor temperature and humidity exposures, but there is little evidence to support this sampling strategy. This study evaluated the relationship between single-point and continuous monitoring of air temperature, apparent temperature, relative humidity, and absolute humidity over four exposure intervals (5-min, 30-min, 24-hr, and 12-days) in 9 northern Utah homes, from March-June 2012. Three homes were sampled twice, for a total of 12 observation periods. Continuous data-logged sampling was conducted in homes for 2-3 wks, and simultaneous single-point measures (n = 114) were collected using handheld thermo-hygrometers. Time-centered single-point measures were moderately correlated with short-term (30-min) data logger mean air temperature (r = 0.76, β = 0.74), apparent temperature (r = 0.79, β = 0.79), relative humidity (r = 0.70, β = 0.63), and absolute humidity (r = 0.80, β = 0.80). Data logger 12-day means were also moderately correlated with single-point air temperature (r = 0.64, β = 0.43) and apparent temperature (r = 0.64, β = 0.44), but were weakly correlated with single-point relative humidity (r = 0.53, β = 0.35) and absolute humidity (r = 0.52, β = 0.39). Of the single-point RH measures, 59 (51.8%) deviated more than ±5%, 21 (18.4%) deviated more than ±10%, and 6 (5.3%) deviated more than ±15% from data logger 12-day means. Where continuous indoor monitoring is not feasible, single-point sampling strategies should include multiple measures collected at prescribed time points based on local conditions.

  13. Sample Size Induced Brittle-to-Ductile Transition of Single-Crystal Aluminum Nitride

    Science.gov (United States)

    2015-08-01

    Aluminum Nitride by GA Gazonas and JW McCauley Weapons and Materials Research Directorate, ARL JJ Guo, KM Reddy, A Hirata, T Fujita, and MW Chen...Sample Size Induced Brittle-to-Ductile Transition of Single-Crystal Aluminum Nitride 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT...their microscopic structure. In this study, we report a size induced brittle-to-ductile transition in single-crystal aluminum nitride (AlN). When the

  14. Analysis of Serum Cytokines and Single-Nucleotide Polymorphisms of SOD1, SOD2, and CAT in Erysipelas Patients

    Directory of Open Access Journals (Sweden)

    Charles C. Emene

    2017-01-01

    Full Text Available Increased free radical production had been documented in group A (β-hemolytic streptococcus infection cases. Comparing 71 erysipelas patients to 55 age-matched healthy individuals, we sought for CAT, SOD1, and SOD2 single polymorphism mutation (SNPs interactions with erysipelas’ predisposition and serum cytokine levels in the acute and recovery phases of erysipelas infection. Whereas female patients had a higher predisposition to erysipelas, male patients were prone to having a facial localization of the infection. The presence of SOD1 G7958, SOD2 T2734, and CAT C262 alleles was linked to erysipelas’ predisposition. T and C alleles of SOD2 T2734C individually were linked to patients with bullous and erythematous erysipelas, respectively. G and A alleles of SOD1 G7958A individually were associated with lower limbs and higher body part localizations of the infection, respectively. Serum levels of IL-1β, CCL11, IL-2Rα, CXCL9, TRAIL, PDGF-BB, and CCL4 were associated with symptoms accompanying the infection, while IL-6, IL-9, IL-10, IL-13, IL-15, IL-17, G-CSF, and VEGF were associated with predisposition and recurrence of erysipelas. While variations of IL-1β, IL-7, IL-8, IL-17, CCL5, and HGF were associated with the SOD2 T2734C SNP, variations of PDFG-BB and CCL2 were associated with the CAT C262T SNP.

  15. Assessing the Validity of Single-item Life Satisfaction Measures: Results from Three Large Samples

    Science.gov (United States)

    Cheung, Felix; Lucas, Richard E.

    2014-01-01

    Purpose The present paper assessed the validity of single-item life satisfaction measures by comparing single-item measures to the Satisfaction with Life Scale (SWLS) - a more psychometrically established measure. Methods Two large samples from Washington (N=13,064) and Oregon (N=2,277) recruited by the Behavioral Risk Factor Surveillance System (BRFSS) and a representative German sample (N=1,312) recruited by the Germany Socio-Economic Panel (GSOEP) were included in the present analyses. Single-item life satisfaction measures and the SWLS were correlated with theoretically relevant variables, such as demographics, subjective health, domain satisfaction, and affect. The correlations between the two life satisfaction measures and these variables were examined to assess the construct validity of single-item life satisfaction measures. Results Consistent across three samples, single-item life satisfaction measures demonstrated substantial degree of criterion validity with the SWLS (zero-order r = 0.62 – 0.64; disattenuated r = 0.78 – 0.80). Patterns of statistical significance for correlations with theoretically relevant variables were the same across single-item measures and the SWLS. Single-item measures did not produce systematically different correlations compared to the SWLS (average difference = 0.001 – 0.005). The average absolute difference in the magnitudes of the correlations produced by single-item measures and the SWLS were very small (average absolute difference = 0.015 −0.042). Conclusions Single-item life satisfaction measures performed very similarly compared to the multiple-item SWLS. Social scientists would get virtually identical answer to substantive questions regardless of which measure they use. PMID:24890827

  16. Assessing the validity of single-item life satisfaction measures: results from three large samples.

    Science.gov (United States)

    Cheung, Felix; Lucas, Richard E

    2014-12-01

    The present paper assessed the validity of single-item life satisfaction measures by comparing single-item measures to the Satisfaction with Life Scale (SWLS)-a more psychometrically established measure. Two large samples from Washington (N = 13,064) and Oregon (N = 2,277) recruited by the Behavioral Risk Factor Surveillance System and a representative German sample (N = 1,312) recruited by the Germany Socio-Economic Panel were included in the present analyses. Single-item life satisfaction measures and the SWLS were correlated with theoretically relevant variables, such as demographics, subjective health, domain satisfaction, and affect. The correlations between the two life satisfaction measures and these variables were examined to assess the construct validity of single-item life satisfaction measures. Consistent across three samples, single-item life satisfaction measures demonstrated substantial degree of criterion validity with the SWLS (zero-order r = 0.62-0.64; disattenuated r = 0.78-0.80). Patterns of statistical significance for correlations with theoretically relevant variables were the same across single-item measures and the SWLS. Single-item measures did not produce systematically different correlations compared to the SWLS (average difference = 0.001-0.005). The average absolute difference in the magnitudes of the correlations produced by single-item measures and the SWLS was very small (average absolute difference = 0.015-0.042). Single-item life satisfaction measures performed very similarly compared to the multiple-item SWLS. Social scientists would get virtually identical answer to substantive questions regardless of which measure they use.

  17. The use of enzyme-linked immunosorbent assay for detection of Mycoplasma hominis antibodies in infertile women serum samples

    DEFF Research Database (Denmark)

    Baczynska, Agata; Friis Svenstrup, Helle; Fedder, Jens

    2005-01-01

    for seropositivity to M. hominis by immunoblotting and a developed ELISA. Women were classified into groups based on the type of infertility: infertile due to lack of passage in Fallopian tubes (TFI, tubal factor infertility), an infertile male partner (MFI, male factor infertility) and unexplained infertility (UFI......BACKGROUND: Besides Chlamydiae trachomatis and Mycoplasma genitalium, Mycoplasma hominis may also cause infertility due to damage of the Fallopian tubes. Therefore serum samples from infertile women were analyzed for antibodies to M. hominis. METHODS: Sera from 304 infertile women were investigated......, unexplained factor infertility). Three M. hominis isolates were used in the immunoblotting analysis and clear differences in patient immunoprofiles were observed between two isolates. For the ELISA we used a mixture of Triton X-114 extracted membrane proteins from those two M. hominis isolates as antigen...

  18. Factors in selecting serum samples for use in determining the positive/negative threshold (cut-off) in ELISA

    International Nuclear Information System (INIS)

    Jacobson, R.H.

    1998-01-01

    The threshold (cut-off) that defines whether a test result is seropositive or seronegative is calculated by testing serum samples from a subpopulation of animals that is assumed to represent the target population in all aspects. For this proposition to be true, it is essential to consider the variables in the target population that must be represented in the subpopulation. Without representation of the variables in the subpopulation, it is likely that the cut-off selected for the test will be errant and will misclassify animals as to their infection status. The purpose of this paper is to identify a few of the principal variables that need to be taken into account when selecting a subpopulation of animals for test validation. (author)

  19. Changes of redox potential in serum samples after in vitro irradiation - an indicator for malignant tumor growth

    International Nuclear Information System (INIS)

    Hamann, D.; Heinrich, H.

    1989-01-01

    In serum samples of healthy persons and patients with malignant neoplasias the redox potentials were determined. Measurings were done in untreated sera and after irradiation with different doses. Sera of healthy persons showed a decrease, those of tumor patients an increase of redox potential values. With this method malignant tumor growth can be demonstrated. It does not allow any statements on tumor localization. On the other hand conclusions seem to be possible on the speed of tumor growth. Estimations of redox potential are applicable to diagnose fast growing recurrences and metastases in tumor aftercare, but can also support the therapeutic procedure decisively in defined differential diagnostic problems and in tumors of questionable dignity. (author)

  20. Serum β-hCG levels post-treatment of ectopic pregnancy with a single dose of intramuscular methotrexate.

    Science.gov (United States)

    Hadinata, Ignatius E; Doyle, Lex W; Thompson, Derrick; Reti, Leslie

    2015-04-01

    The cytotoxic management of ectopic pregnancy using a single dose of intramuscular methotrexate injection has been well established as effective for a select number of women with unruptured tubal ectopic pregnancy where there are minimal symptoms. The purpose of this study was to create centile curves of serum β-hCG levels following successful treatment with a single dose of 50 mg/m(2) of intramuscular methotrexate to treat ectopic pregnancy. Data were retrieved from women treated at the Royal Women's Hospital for ectopic pregnancy between 2006 and 2012. Only women with minimal symptoms, initial serum β-hCG ≤5000 IU/L and ectopic mass size of ≤35 mm on ultrasound were included. Two hundred and fifty-three cases of ectopic pregnancy were analysed. Initial β-hCG of women in the study ranged from 18 to 3995 IU/L with a median of 497 (25th to 75th centiles; 222-1160) IU/L. The median levels of β-hCG levels at day 4, 7 and 14 postmethotrexate injection were 73.8, 47.2 and 10.4% of the initial β-hCG level, respectively. The 90th centiles of β-hCG levels at day 4, 7 and 14 were 124.7, 93.8 and 40.0% of initial β-hCG level, respectively. Whilst no comparison with those unsuccessfully treated was made, pending further validation studies, the use of these curves may reduce the reliance on specialist units and streamline care for many women with ectopic pregnancy, such as those whose β-hCG regress in line with centile values without crossing a certain threshold. © 2015 The Royal Australian and New Zealand College of Obstetricians and Gynaecologists.

  1. High-pressure oxygenation of thin-wall YBCO single-domain samples

    International Nuclear Information System (INIS)

    Chaud, X; Savchuk, Y; Sergienko, N; Prikhna, T; Diko, P

    2008-01-01

    The oxygen annealing of ReBCO bulk material, necessary to achieve superconducting properties, usually induces micro- and macro-cracks. This leads to a crack-assisted oxygenation process that allows oxygenating large bulk samples faster than single crystals. But excellent superconducting properties are cancelled by the poor mechanical ones. More progressive oxygenation strategy has been shown to reduce drastically the oxygenation cracks. The problem then arises to keep a reasonable annealing time. The concept of bulk Y123 single-domain samples with thin-wall geometry has been introduced to bypass the inherent limitation due to a slow oxygen diffusion rate. But it is not enough. The use of a high oxygen pressure (16 MPa) enables to speed up further the process. It introduces a displacement in the equilibrium phase diagram towards higher temperatures, i.e., higher diffusion rates, to achieve a given oxygen content in the material. Remarkable results were obtained by applying such a high pressure oxygen annealing process on thin-wall single-domain samples. The trapped field of 16 mm diameter Y123 thin-wall single-domain samples was doubled (0.6T vs 0.3T at 77K) using an annealing time twice shorter (about 3 days). The initial development was made on thin bars. The advantage of thin-wall geometry is that such an annealing can be applied directly to a much larger sample

  2. Diagnostic Impacts of Serum CA-125 Levels, Pap Smear Evaluation, and Endometrial Sampling in Women with Endometrial Clear Cell Carcinoma.

    Science.gov (United States)

    Cetinkaya, Nilufer; Selcuk, İlker; Ozdal, Bulent; Meydanli, Mehmet M; Gungor, Tayfun

    2016-01-01

    Endometrial clear cell carcinoma (ECCC) is a rare variant of endometrial cancer with an unfavorable prognosis. The aim of this study was to determine the relationships, if any, between preoperative serum cancer antigen 125 (CA-125) levels, the last Papanicolaou (Pap) smear, the results of endometrial biopsy and tumor histology, and disease-stage according to permanent histopathology. The data of 26 women with ECCC were collected from their medical records to compare demographics, preoperative serum CA-125 levels, Pap test results, histological diagnosis of the endometrial biopsy, and tumor histology, as well as the disease stage according to permanent histopathology. The mean age at diagnosis was 64.0 years. There were 17 (65.3%) women with pure ECCC and 8 (30.7%) women with a mixed histology. Stage III-IV disease was diagnosed in 12 (46.2%) women and occurred more frequently in pure ECCC (n = 11, 91.7%). CA-125 values were significantly higher in advanced stage disease. Cytological evaluation indicated the presence of 71.4% (10/14) cytological abnormalities in pure ECCC. The overall sensitivity of endometrial sampling for the detection of malignancy was 92.3% (24/26), whereas the accurate diagnosis of ECCC was only 34.7% (8/23) with the Pipelle sampler. Pap test abnormalities are frequent in ECCC. Although it is less accurate in the diagnosis of ECCC than in the detection of malignancy, endometrial sampling is still the main procedure for the diagnosis of ECCC. Higher preoperative CA-125 concentrations imply the presence of advanced stage ECCC. © 2016 S. Karger GmbH, Freiburg.

  3. Preparation and characterization of single crystal samples for high-pressure experiments

    Energy Technology Data Exchange (ETDEWEB)

    Farber, D; Antonangeli, D; Aracne, C; Benterou, J

    2005-10-26

    To date, most research utilizing the diamond anvil cell (DAC) has been conducted with polycrystalline samples, thus the results are limited to addressing average bulk properties. However, experiments on single crystals can yield data on a range of orientation dependent properties such as thermal and electrical conductivity, magnetic susceptibility, elasticity and plasticity. Here we report new procedures to produce extremely high-quality metallic single crystal samples of size compatible with DAC experiments in the Mbar range. So far, we have produced samples of zinc, Al{sub 2}O{sub 3}, cobalt, molybdenum and cerium, and have evaluated the quality of the finished samples with white-light interferometry, synchrotron x-ray diffraction and inelastic x-ray scattering.

  4. Effects of Pretreating Serum Samples on the Performance of a Latex Agglutination Test for Serodiagnosis of Paracoccidioidomycosis

    Science.gov (United States)

    Silveira-Gomes, Fabíola

    2012-01-01

    Paracoccidioidomycosis (PCM) is a fungal disease caused by Paracoccidioides brasiliensis, and Brazil is one of the principal countries where it is endemic. Diagnosis is based on the observation of budding P. brasiliensis yeast in clinical specimens from patients; however, the sensitivity of the visualization of fungi is low, indicating that serological tests are used for early diagnosis. The double-immunodiffusion test (ID) is the “gold standard” test for serology in PCM, although the execution of this test requires the availability of laboratorial infrastructure. We report the improved performance of a latex agglutination test (LAT) by pretreating 30 serum samples from PCM patients and 71 controls (histoplasmosis and aspergillosis patients, patients with bacterial infections, and normal human sera) with a dilution buffer incubated at 37°C for 30 min. The sensitivity and specificity of the LAT test in the nonpretreated samples were 73% and 79%, respectively. However, when samples were pretreated, the sensitivity and specificity of the test increased to 90%. In this study, we did not observe cross-reactivity with histoplasmosis patient sera, but some reactions to sera from patients with aspergillosis and bacterial infections were noted. Normal human sera were not reactive in our tests. These results indicate the need for the elimination of heterologous reactions so that we can adequately use this method for screening cases of PCM. PMID:22205661

  5. Sample Preparation Strategies for the Effective Quantitation of Hydrophilic Metabolites in Serum by Multi-Targeted HILIC-MS/MS

    Directory of Open Access Journals (Sweden)

    Elisavet Tsakelidou

    2017-03-01

    Full Text Available The effect of endogenous interferences of serum in multi-targeted metabolite profiling HILIC-MS/MS analysis was investigated by studying different sample preparation procedures. A modified QuEChERS dispersive SPE protocol, a HybridSPE protocol, and a combination of liquid extraction with protein precipitation were compared to a simple protein precipitation. Evaluation of extraction efficiency and sample clean-up was performed for all methods. SPE sorbent materials tested were found to retain hydrophilic analytes together with endogenous interferences, thus additional elution steps were needed. Liquid extraction was not shown to minimise matrix effects. In general, it was observed that a balance should be reached in terms of recovery, efficient clean-up, and sample treatment time when a wide range of metabolites are analysed. A quick step for removing phospholipids prior to the determination of hydrophilic endogenous metabolites is required, however, based on the results from the applied methods, further studies are needed to achieve high recoveries for all metabolites.

  6. The effects of bacterial endotoxin on lipide metabolism. I. The responses of the serum lipides of rabbits to single and repeated injections of Shear's polysaccharide.

    Science.gov (United States)

    LEQUIRE, V S; HUTCHERSON, J D; HAMILTON, R L; GRAY, M E

    1959-08-01

    Single intravenous injections of Shear's polysaccharide in varying dosages invariably produced an elevation in the levels of the total serum lipides 24 hours after injection of endotoxin. The total serum cholesterol and lipide phosphorus were also affected, although they did not change with smaller doses of endotoxin and were rarely elevated to the same degree as were the total serum lipides. The degree of elevation of the serum lipides was apparently related to the amount of endotoxin injected up to a certain point, beyond which there was no further increase. There were two types of response to endotoxin by the serum lipides, a moderate increase and an uncontrolled increase. Higher dosages of endotoxin and fasting apparently increased the incidence of the latter response. No direct correlation could be made between serum lipide responses and histologic evidence typical of the generalized Shwartzman reaction following this regimen of endotoxin injection. The Shwartzman reaction did occur with greater frequency and with lower dosages of endotoxin in fasted animals. Animals given repeated injections of endotoxin showed an initial increase in serum lipides followed by a progressive decrease to normal levels as tolerance to the febrile action of endotoxin appeared. The febrile tolerance as well as the unresponsiveness of the serum lipides to endotoxin was abolished by thorium dioxide (thorotrast) in these animals. In similar experiments a "breakthrough" of lipide unresponsiveness to endotoxin was obtained by increasing the amount of endotoxin injected. Some of the implications of these results for the metabolic alterations produced by bacterial endotoxins are discussed.

  7. Serum Uric Acid, Kidney Function and Acute Ischemic Stroke Outcomes in Elderly Patients: A Single-Cohort, Perspective Study.

    Science.gov (United States)

    Falsetti, Lorenzo; Capeci, William; Tarquinio, Nicola; Viticchi, Giovanna; Silvestrini, Mauro; Catozzo, Vania; Fioranelli, Agnese; Buratti, Laura; Pellegrini, Francesco

    2017-02-20

    Chronic kidney disease and hyperuricemia have been associated to an increased risk and a worse prognosis in acute ischemic stroke. Several mechanisms, including platelet dysfunction, coagulation disorders, endothelial dysfunction, inflammation, and an increased risk of atrial fibrillation could be implicated. The role of serum uric acid in this setting is still object of debate. We enrolled all the consecutive patients admitted to our department for acute ischemic stroke. Cox regression analysis was used to evaluate the risk of in-hospital death considering serum uric acid levels and all the comorbidities. In the overall sample, hyperuricemia was independently associated to an increased risk of in-hospital mortality. This effect was stronger in patients with chronic kidney disease while, in the group of patients with normal renal function, the relationship between hyperuricemia and increased stroke mortality was not confirmed. Hyperuricemia could be associated to higher in-hospital mortality for ischemic stroke among elderly patients when affected by kidney disease. Survival does not seem to be affected by hyperuricemia in patients with normal kidney function.

  8. Serum uric acid, kidney function and acute ischemic stroke outcomes in elderly patients: a single-cohort, perspective study

    Directory of Open Access Journals (Sweden)

    Lorenzo Falsetti

    2017-03-01

    Full Text Available Chronic kidney disease and hyperuricemia have been associated to an increased risk and a worse prognosis in acute ischemic stroke. Several mechanisms, including platelet dysfunction, coagulation disorders, endothelial dysfunction, inflammation, and an increased risk of atrial fibrillation could be implicated. The role of serum uric acid in this setting is still object of debate. We enrolled all the consecutive patients admitted to our department for acute ischemic stroke. Cox regression analysis was used to evaluate the risk of in-hospital death considering serum uric acid levels and all the comorbidities. In the overall sample, hyperuricemia was independently associated to an increased risk of in-hospital mortality. This effect was stronger in patients with chronic kidney disease while, in the group of patients with normal renal function, the relationship between hyperuricemia and increased stroke mortality was not confirmed. Hyperuricemia could be associated to higher in-hospital mortality for ischemic stroke among elderly patients when affected by kidney disease. Survival does not seem to be affected by hyperuricemia in patients with normal kidney function.

  9. Evaluation of heat-treating heartworm-positive canine serum samples during treatment with Advantage Multi® for Dogs and doxycycline

    OpenAIRE

    Molly D. Savadelis; Jennifer L. Roveto; Cameon M. Ohmes; Joe A. Hostetler; Terry L. Settje; Michael T. Dzimianski; Andrew R. Moorhead

    2018-01-01

    Abstract Background The use of heat-treatment in canine and feline serum has been hypothesized to break the formation of antigen-antibody complexes, thereby freeing the heartworm antigen allowing for detection by commercially available heartworm antigen kits. While studies have analyzed the effect of heat-treating serum and plasma samples in the detection of heartworm antigen, these studies have not utilized necropsy verified results for validation. This study evaluated the use of heat-treati...

  10. Pretreatment serum human chorionic gonadotropin cutoff value for medical treatment success with single-dose and multi-dose regimen of methotrexate in tubal ectopic pregnancy.

    Science.gov (United States)

    Kim, Junhwan; Jung, Young Mi; Lee, Da Yong; Jee, Byung Chul

    2017-01-01

    To investigate individual pretreatment serum human chorionic gonadotropin (hCG) cutoff value for medical treatment success with single-dose and multi-dose regimen of methotrexate in tubal ectopic pregnancy. Eighty-five women who received methotrexate for the treatment of tubal ectopic pregnancy during 2003 to 2015 were selected. Fifty-three women received a single-dose regimen and 32 women received a multi-dose regimen. Medical treatment failure was defined as necessity of surgical treatment. The medical treatment success rate was estimated in both regimens and the pretreatment serum hCG titer to predict the success was assessed by receiver operating characteristics curve analysis. Pretreatment clinical and laboratory parameters were similar between group of single-dose regimen and multi-dose regimen. Treatment success rate was 64.2% in the single-dose regimen group and 71.9% in the multi-dose regimen group ( P >0.05). Pretreatment serum hCG titer was an independent prognostic factor for treatment success in each regimen. Serum hCG cutoff value to predict the treatment success was 3,026 IU/L in single-dose regimen group and 3,711 IU/L in multi-dose regimen group. We recommend use of single-dose regimen when pretreatment serum hCG <3,026 IU/L but multi-dose regimen may be favored when initial serum hCG level between 3,026 and 3,711 IU/L.

  11. Evaluation of calcium, magnesium, potassium, and sodium in biological samples (scalp hair, serum, blood, and urine) of Pakistani referents and arthritis patients of different age groups.

    Science.gov (United States)

    Afridi, Hassan Imran; Kazi, Tasneem Gul; Kazi, Naveed; Shah, Abdul Qadir; Khan, Sumaira; Kolachi, Nida Fatima; Wadhwa, Sham Kumar; Shah, Faheem

    2012-01-01

    Rheumatoid Arthritis is a chronic inflammatory disease resulting in joint inflammation (particularly joints of hands, wrists, feet, knees, ankles, and shoulder) that is manifested by swelling and functional impairment. This study was designed to compare the levels of calcium (Ca), magnesium (mg), potassium (K), and sodium (Na) in four biological samples (scalp hair, serum, blood, and urine) of patients with rheumatoid arthritis (RA) as compared to referent subjects of both genders who do have not arthritis problems. All patients and referents were divided in two age groups, (46-60) and (61-75) years. A microwave assisted wet acid digestion procedure was used for acid digestion of biological samples. The digests of all biological samples were analysed for Ca, Mg, K, and Na by flame atomic absorption spectrometry (FAAS). The proposed method was validated by using conventional wet digestion of the same sub samples and certified reference samples of hair, serum, blood, and urine. The results indicated significantly lower levels of Ca, Mg, and K in the biological samples (blood, serum, and scalp hair) of male and female rheumatoid arthritis patients when compared to referents of both genders, whereas the levels of Na were found to be high in blood and urine samples of patients as compared to nonrheumatic referents. These data represent a guide for clinicians and other professionals who will be investigating the deficiency of essential micronutrients in biological samples (scalp hair, serum, and blood) of rheumatoid arthritis patients.

  12. Evaluation of enzyme-linked immunosorbent assays performed on milk and serum samples for detection of neosporosis and leukosis in lactating dairy cows.

    Science.gov (United States)

    Walsh, Robert B; Kelton, David F; Hietala, Sharon K; Duffield, Todd F

    2013-04-01

    Serum and milk samples from 1229 cows on 22 Ontario dairy farms were individually tested for antibodies specific for bovine leukosis virus (BLV) and Neospora caninum by enzyme-linked immunosorbent assay (ELISA). Antibodies against BLV were present in 361 serum samples (29.4%) and 369 milk samples (30.0%). Comparing the 2 tests, agreement was almost perfect (k = 0.86; 95% CI = 0.83 to 0.90) and the proportions of samples positive were not significantly different (P = 0.56). Both tests identified the same 3 herds free of bovine leukosis virus. Antibodies against N. caninum were detected in 138 serum samples (11.2%), and 111 milk samples (9.0%). Agreement between the 2 tests was moderate (k = 0.52; 95% CI = 0.43 to 0.59). Four herds were free of neosporosis by the serum test, while 10 herds were negative by the milk test. The ELISA on milk samples facilitates sample collection to classify herds free of BLV; the milk N. caninum ELISA was less reliable in predicting herd-level infection.

  13. Anti-Toxoplasma gondii antibody detection in serum and urine samples by enzyme-linked immunosorbent assay in HIV-infected patients

    Directory of Open Access Journals (Sweden)

    Sayan Bhattacharyya

    2013-01-01

    Full Text Available Background: Toxoplasmosis is a common parasitic infection of man, and reactivation of latent disease in HIV-infected patients can cause fatal encephalitis. Diagnosis depends on demonstration of parasite-specific antibodies in serum. In HIV-infected patients, IgM is often undetectable, whereas IgG remains detectable in the majority. Urine sample is very easily available and has not been evaluated for immunodiagnosis of toxoplasmosis. Aim: The study was an effort to find whether urine sample can be used in place of serum for immunodiagnosis of toxoplasmosis. Materials and Methods: Enzyme-linked immunosorbent assay (ELISA was carried out in serum and urine samples collected from 100 HIV-infected patients to detect anti-toxoplasma IgG and IgM antibodies and whether positivity correlated with the CD4 T-cell counts of patients. Results: In this study, we observed that there was no significant difference in positivity of anti-toxoplasma IgM and IgG between serum and urine samples of HIV-infected patients by ELISA. There was a negative correlation between CD4 count and seropositivity. Conclusion: Urine sample can be satisfactorily used in place of serum for immunodiagnosis of toxoplasmosis.

  14. Factors associated with serum B-type natriuretic peptide in infants with single ventricles.

    Science.gov (United States)

    Butts, Ryan J; Zak, Victor; Hsu, Daphne; Cnota, James; Colan, Steven D; Hehir, David; Kantor, Paul; Levine, Jami C; Margossian, Renee; Richmond, Marc; Szwast, Anita; Williams, Derek; Williams, Richard; Atz, Andrew M

    2014-06-01

    Data regarding the value of B-type natriuretic peptide (BNP) measurements in infants with a single-ventricle (SV) physiology are lacking. This analysis aimed to describe the BNP level changes in infants with an SV physiology before and after superior cavopulmonary connection (SCPC) surgery. Levels of BNP were measured by a core laboratory before SCPC (at 5.0 ± 1.6 months) and at the age of 14 months during a multicenter trial of angiotensin-converting enzyme inhibition therapy for infants with SV. Multivariable longitudinal analysis was used to model the associations between BNP levels and three sets of grouped variables (echocardiography, catheterization, growth). Multivariable analysis was performed to assess associations with patient characteristics at both visits. Associations between BNP levels and neurodevelopmental variables were investigated at the 14 month visit because neurodevelopmental assessment was performed only at this visit. The BNP level was significantly higher before SCPC (n = 173) than at the age of 14 months (n = 134). The respective median levels were 80.8 pg/ml (interquartile range [IQR], 35-187 pg/ml) and 34.5 pg/ml (IQR, 17-67 pg/ml) (p SCPC and in 21 subjects (16 %) at the age of 14 months. In the 117 patients who had BNP measurements at both visits, the median BNP level decreased 32 pg/ml (IQR, 1-79 pg/ml) (p SCPC surgery (p SCPC surgery (p = 0.04), and a lower Bayley psychomotor developmental index (p = 0.02). The levels of BNP decreases in infants with SV from the pre-SCPC visit to the age of 14 months. A higher BNP level is associated with increased ventricular dilation in systole, increased AV valve regurgitation, impaired growth, and poorer neurodevelopmental outcomes. Therefore, BNP level may be a useful seromarker for identifying infants with SV at risk for worse outcomes.

  15. Single injection 51Cr EDTA plasma clearance determination in children using capillary blood samples

    International Nuclear Information System (INIS)

    Broechner-Mortensen, J.; Christoffersen, J.

    1977-01-01

    The reliability of a determination of the total 51 Cr EDTA plasma clearance (e) (and with it the glomerular filtration rate), by a simplified single injection method (injected dose: 4.5 μCi per kg b.w.) using capillary blood samples (0.2 ml), was investigated in twenty children. Clearance values determined from capillary blood samples did not differ significantly from those measured simultaneously from venous blood samples, the mean ratio+-SD being 1.02+-0.06(n = 10). The reproducibility (total day-to-day variation) of E determined from capillary blood samples was 6.7% in children with decreased renal function (n = 3) and 6.9% in children with normal renal function (n = 7). The present data indicate that the use of capillary blood samples is an accurate and very precise approach for determination of E in children. (Auth.)

  16. Brominated flame retardants in the hair and serum samples from an e-waste recycling area in southeastern China: the possibility of using hair for biomonitoring.

    Science.gov (United States)

    Liang, Si; Xu, Feng; Tang, Weibiao; Zhang, Zheng; Zhang, Wei; Liu, Lili; Wang, Junxia; Lin, Kuangfei

    2016-08-01

    Hair samples and paired serum samples were collected from e-waste and urban areas in Wenling of Zhejiang Province, China. The PBDE and DBDPE concentrations in hair and serum samples from e-waste workers were significantly higher than those of non-occupational residents and urban residents. BDE209 was the dominating BFRs in hair and serum samples from the e-waste area, while DBDPE was the major BFRs from the urban area. Statistically significant correlations were observed between hair level and serum level for some substances (BDE209, DBDPE, BDE99, BDE47, BDE28, and BDE17), although the PBDE congener profiles in hair were different from those in the serum. A statistically significant positive correlation between the PBDE concentrations and the working age, as well as gender difference, was observed in e-waste workers. Different sources of PBDEs and DBDPE in three groups were identified by principal component analysis and spearman correlation coefficient. Hair is suggested to be a useful matrix for biomonitoring the PBDE exposure in humans.

  17. Metabolic profiling of serum samples by 1H nuclear magnetic resonance spectroscopy as a potential diagnostic approach for septic shock.

    Science.gov (United States)

    Mickiewicz, Beata; Duggan, Gavin E; Winston, Brent W; Doig, Christopher; Kubes, Paul; Vogel, Hans J

    2014-05-01

    To determine whether a nuclear magnetic resonance-based metabolomics approach can be useful for the early diagnosis and prognosis of septic shock in ICUs. Laboratory-based study. University research laboratory. Serum samples from septic shock patients and ICU controls (ICU patients with systemic inflammatory response syndrome but not suspected of having an infection) were collected within 24 hours of admittance to the ICU. None. H nuclear magnetic resonance spectra of septic shock and ICU control samples were analyzed and quantified using a targeted profiling approach. By applying multivariate statistical analysis (e.g., orthogonal partial least squares discriminant analysis), we were able to distinguish the patient groups and detect specific metabolic patterns. Some of the metabolites were found to have a significant impact on the separation between septic shock and control samples. These metabolites could be interpreted in terms of a biological human response to septic shock and they might serve as a biomarker pattern for septic shock in ICUs. Additionally, nuclear magnetic resonance-based metabolomics was evaluated in order to detect metabolic variation between septic shock survivors and nonsurvivors and to predict patient outcome. The area under the receiver operating characteristic curve indicated an excellent predictive ability for the constructed orthogonal partial least squares discriminant analysis models (septic shock vs ICU controls: area under the receiver operating characteristic curve = 0.98; nonsurvivors vs survivors: area under the receiver operating characteristic curve = 1). Our results indicate that nuclear magnetic resonance-based metabolic profiling could be used for diagnosis and mortality prediction of septic shock in the ICU.

  18. Using a decline in serum hCG between days 0–4 to predict ectopic pregnancy treatment success after single-dose methotrexate: a retrospective cohort study

    Directory of Open Access Journals (Sweden)

    Skubisz Monika

    2013-02-01

    Full Text Available Abstract Background The current measure of treatment efficacy of single-dose methotrexate for ectopic pregnancy, is a fall in serum hCG of ≥15% between days 4–7 of treatment, which has a positive predictive value of 93% for treatment success. Two small studies have proposed a fall in serum hCG between days 0–4 after treatment confers similar, earlier prognostic information, with positive predictive values of 100% and 88% for treatment success. We sought to validate this in a large, independent cohort because of the potentially significant clinical implications. Methods We conducted a retrospective study of women (n=206 treated with single-dose methotrexate for ectopic pregnancy (pre-treatment serum hCG levels ≤3000 IU/L at Scottish hospitals between 2006–2011. Women were divided into two cohorts based on whether their serum hCG levels rose or fell between days 0–4 after methotrexate. Treatment outcomes of women in each cohort were compared, and the test performance characteristics calculated. This methodology was repeated for the current measure (≥15% fall in serum hCG between days 4–7 of treatment and an alternate early measure ( Results In our cohort, the positive predictive value of the current clinical measure was 89% (95% CI 84-94% (121/136. A falling serum hCG between days 0–4 predicted treatment success in 85% (95% CI 79-92% of cases (94/110 and a Conclusions We have verified that a decline in serum hCG between days 0–4 after methotrexate treatment for ectopic pregnancies, with pre-treatment serum hCG levels ≤3000 IU/L, provides an early indication of likelihood of treatment success, and performs just as well as the existing measure, which only provides prognostic information on day 7.

  19. Single- versus multiple-sample method to measure glomerular filtration rate.

    Science.gov (United States)

    Delanaye, Pierre; Flamant, Martin; Dubourg, Laurence; Vidal-Petiot, Emmanuelle; Lemoine, Sandrine; Cavalier, Etienne; Schaeffner, Elke; Ebert, Natalie; Pottel, Hans

    2018-01-08

    There are many different ways to measure glomerular filtration rate (GFR) using various exogenous filtration markers, each having their own strengths and limitations. However, not only the marker, but also the methodology may vary in many ways, including the use of urinary or plasma clearance, and, in the case of plasma clearance, the number of time points used to calculate the area under the concentration-time curve, ranging from only one (Jacobsson method) to eight (or more) blood samples. We collected the results obtained from 5106 plasma clearances (iohexol or 51Cr-ethylenediaminetetraacetic acid (EDTA)) using three to four time points, allowing GFR calculation using the slope-intercept method and the Bröchner-Mortensen correction. For each time point, the Jacobsson formula was applied to obtain the single-sample GFR. We used Bland-Altman plots to determine the accuracy of the Jacobsson method at each time point. The single-sample method showed within 10% concordances with the multiple-sample method of 66.4%, 83.6%, 91.4% and 96.0% at the time points 120, 180, 240 and ≥300 min, respectively. Concordance was poorer at lower GFR levels, and this trend is in parallel with increasing age. Results were similar in males and females. Some discordance was found in the obese subjects. Single-sample GFR is highly concordant with a multiple-sample strategy, except in the low GFR range (<30 mL/min). © The Author 2018. Published by Oxford University Press on behalf of ERA-EDTA. All rights reserved.

  20. Sampling and single particle analysis for the chemical characterisation of fine atmospheric particulates: A review.

    Science.gov (United States)

    Elmes, Michele; Gasparon, Massimo

    2017-11-01

    To better understand the potential environmental and human health impacts of fine airborne particulate matter (APM), detailed physical and chemical characterisation is required. The only means to accurately distinguish between the multiple compositions in APM is by single particle analysis. A variety of methods and instruments are available, which range from filter-based sample collection for off-line laboratory analysis to on-line instruments that detect the airborne particles and generate size distribution and chemical data in real time. There are many reasons for sampling particulates in the ambient atmosphere and as a consequence, different measurement strategies and sampling devices are used depending on the scientific objectives and subsequent analytical techniques. This review is designed as a guide to some of the techniques available for the sampling and subsequent chemical analysis of individual inorganic particles. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. A simple microfluidic dispenser for single-microparticle and cell samples.

    Science.gov (United States)

    Kasukurti, A; Eggleton, C D; Desai, S A; Disharoon, D I; Marr, D W M

    2014-12-21

    Non-destructive isolation of single-cells has become an important need for many biology research laboratories; however, there is a lack of easily employed and inexpensive tools. Here, we present a single-particle sample delivery approach fabricated from simple, economical components that may address this need. In this, we employ unique flow and timing strategies to bridge the significant force and length scale differences inherent in transitioning from single particle isolation to delivery. Demonstrating this approach, we use an optical trap to isolate individual microparticles and red blood cells that are dispensed within separate 50 μl droplets off a microfluidic chip for collection into microscope slides or microtiter plates.

  2. Determination of the maleic acid in rat urine and serum samples by isotope dilution-liquid chromatography-tandem mass spectrometry with on-line solid phase extraction.

    Science.gov (United States)

    Chen, Hsin-Chang; Wu, Charlene; Wu, Kuen-Yuh

    2015-05-01

    A rapid and simple on-line solid-phase extraction coupled with isotope dilution-liquid chromatography-tandem mass spectrometry (SPE-ID-LC-MS/MS) method was developed to quantitate maleic acid in serum and urine of SpragueDawley (SD) rats. The aforementioned biological samples were spiked with (13)C2-maleic acid, vigorously vortexed, added with acetonitrile to precipitate proteins, and then injected into the on-line SPE-LC-MS/MS system for quantification. Upon validation, this method demonstrated excellent feasibility and sensitivity: calibration curves for maleic acid in serum and urine display excellent linearity with the coefficient of determination (R(2)) greater than 0.999; the limits of detection and quantitation (LOD and LOQ) for maleic acid were determined at 0.2 and 0.5μg L(-1), respectively. Additionally, intra-day accuracy for maleic acid in serum and urine samples ranged from 94.0% to 100.2% and 101.3% to 104.4%, respectively. Furthermore, inter-day accuracy ranged from 93.6% to 101.0% and from 102.3% to 111.4% in serum and urine samples, respectively. Intra-day precision %RSD of maleic acid in serum and urine samples was 13.8% or less, whereas the inter-day precision was 6.1% or less. The matrix effects were not found to be statistically significant (p=0.9145 and p=0.5378, correspondingly) based on the calculations of recovery functions. The collected serum and urine samples were analyzed using SPE-ID-LC-MS/MS. Our results reveal trace levels of maleic acid in the control rats, demonstrating that this method is capable of analyzing background levels of contaminants in biofluids with excellent sensitivity and specificity at part-per-billion levels concentrations in complex matrices. Copyright © 2015. Published by Elsevier B.V.

  3. Antinuclear, Cytoskeletal, Antineuronal Antibodies in the Serum Samples of Children with Tic Disorders and Obsessive Compulsive Disorders

    Directory of Open Access Journals (Sweden)

    Işık Görker

    2011-11-01

    Full Text Available streptococcus infections in the development of tic and obsessive compulsive disorders (OCD is controversial. The autoimmune hypothesis states that during infection, formation of autoantibodies leads to an autoimmune disorder, which in turn results in movement disorders, tic disorders and/or OCD. In order to test this hypothesis, we assayed these antibodies in children and adolescents diagnosed with tic disorders and/or OCD.Material and Methods: Children and adolescents who were diagnosed with either tic disorders or OCD according to DSM-IV criteria (n=28, were compared with healthy controls (n=15 having similar age and gender characteristics. Regardless of a streptococcus infection history, serum samples of all patients and controls underwent antinuclear, cytoskeletal, and antineuronal antibody assay using indirect immunofluorescence.Results: The rates of antinuclear antibody positivity were 21% and 20% in the patient and control groups respectively (p>0.05. Antineuronal antibody was positive in 2 (7% of 28 patients versus in 1 (6% of 15 controls (p>0.05.Conclusion: These results suggest that such antibodies may not be involved in the pathogenesis of tic disorders/OCD.

  4. Determinants of serum IgG responses to periodontal bacteria in a nationally representative sample of US adults.

    Science.gov (United States)

    Vlachojannis, Christian; Dye, Bruce A; Herrera-Abreu, Miriam; Pikdöken, Levent; Lerche-Sehm, Julia; Pretzl, Bernadette; Celenti, Romanita; Papapanou, Panos N

    2010-08-01

    To assess the distribution of elevated antibody titres to multiple periodontal bacteria, including established/putative pathogens and health-related species, by selected demographic, behavioural, and oral- and general health-related characteristics. Data from 8153 >or=40-year-old participants from the third National Health and Nutrition Examination Survey were used, including 1588 edentulous individuals. We used checkerboard immunoblotting to assess serum IgG levels to 19 periodontal species. Thresholds for elevated antibody responses were defined for each species using the 90th percentile titre in periodontal healthy participants, using two alternative definitions of periodontitis. Edentulous individuals showed lower antibody responses than dentate participants, notably for titres to "red complex" species and Actinobacillus actinomycetemcomitans. Elevated titres to Porphyromonas gingivalis were twice as prevalent in participants with periodontitis than in periodontal healthy individuals. Non-Hispanic blacks and Mexican-Americans were more likely to display elevated titres for P. gingivalis compared with non-Hispanic whites (22.9%versus 19.4%versus 9.5%). Current smokers were significantly less likely to exhibit high titres to multiple bacteria than never smokers. Demographic, behavioural, and oral- and general health-related characteristics were strong determinants of systemic antibody responses to periodontal bacteria in a nationally representative sample of US adults.

  5. Implementation of a SPR immunosensor for the simultaneous detection of the 22K and 20K hGH isoforms in human serum samples.

    Science.gov (United States)

    de Juan-Franco, Elena; Rodríguez-Frade, J M; Mellado, M; Lechuga, Laura M

    2013-09-30

    We have implemented a Surface Plasmon Resonance (SPR) immunosensor based on a sandwich assay for the simultaneous detection of the two main hGH isoforms, of 22 kDa (22K) and 20 kDa (20K). An oriented-antibody sensor surface specific for both hormone isoforms was assembled by using the biotin-streptavidin system. The immunosensor functionality was checked for the direct detection of the 22K hGH isoform in buffer, which gave high specificity and reproducibility (intra and inter-assay mean coefficients of variation of 8.23% and 9% respectively). The selective determination of the 22K and 20K hGH isoforms in human serum samples in a single assay was possible by using two specific anti-hGH monoclonal antibodies. The detection limit for both hormone isoforms was 0.9 ng mL(-1) and the mean coefficient of variation was below 7.2%. The excellent reproducibility and sensitivity obtained indicate the high performance of this immunosensor for implementing an anti-doping test. Copyright © 2013 Elsevier B.V. All rights reserved.

  6. Investigation of applicability of extrapolation method for sample field determination in single-yoke measuring setup

    Czech Academy of Sciences Publication Activity Database

    Stupakov, Oleksandr

    2006-01-01

    Roč. 307, - (2006), s. 279-287 ISSN 0304-8853 R&D Projects: GA AV ČR(CZ) 1QS100100508 Institutional research plan: CEZ:AV0Z10100520 Keywords : magnetic measurement * open magnetic sample * surface field determination * single-yoke setup * magnetic non-destructive testing Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 1.212, year: 2006

  7. Chromium-51-EDTA clearance in adults with a single-plasma sample.

    Science.gov (United States)

    Mårtensson, J; Groth, S; Rehling, M; Gref, M

    1998-12-01

    In 1996, a committee on renal clearance recommended a mean sojourn time-based methodology for single-sample determination of plasma clearance of 99mTc-diethylenetriamine pentaacetic acid (DTPA) to be used on adults if the patient's glomerular filtration rate (GFR) is suspected to be >30 ml/min. The main purpose of this study was to derive a mean sojourn time-based formula for calculation of 51Cr-ethylenediamine tetraacetic acid (EDTA) clearance in adults. Two groups of patients with 51Cr-EDTA clearance (Cl) between 16 and 172 ml/min were studied. In Group I (n = 46), reference Cl was determined as a multiplasma sample, single-injection method (ClSM). Sixteen blood samples were drawn from 0 until 5 hr after a single intravenous injection of 51Cr-EDTA. In Group II (n = 1046), reference Cl was determined by the Brøchner-Mortensen four-sample clearance method (ClBM). The plasma time-activity curves of Group I were used to derive two mean sojourn time-based formulas (Formulas 1 and 2) for calculation of a single-sample clearance. Formula 1 was derived from the entire time-activity curve, whereas the derivation of Formula 2 used only the final slope of the time-activity curve. The accuracy of the two formulas and the Christensen and Groth 99mTc-DTPA formula was tested on Group II. Chromium-51-EDTA Cl calculated by Formula 1 was almost identical to the Cl calculated by the reference Cl method (r = 0.982; SDdiff = 5.82 ml/min). Both 51Cr-EDTA Cl calculated by Formula 2 and by the 99mTc-DTPA formula showed close correlation with the reference method (r = 0.976, r = 0.985, respectively) but systematically overestimated GFR for the whole range of clearance values by 3.5 and 3.2 ml/min (ptime methodology. The determination is marginally more accurate (ptime-activity curve than from only the final slope. The single-sample formula derived for determination of 99mTc-DTPA Cl tends slightly to overestimate GFR if used to calculate 51Cr-EDTA Cl.

  8. Non-covalent attachment of silver nanoclusters onto single-walled carbon nanotubes with human serum albumin as linking molecule

    Energy Technology Data Exchange (ETDEWEB)

    Rodríguez-Galván, Andrés, E-mail: andres.rodriguez@nucleares.unam.mx [Instituto de Ciencias Nucleares, Universidad Nacional Autónoma de México, Circuito Exterior C.U., 04510 México D.F. (Mexico); Instituto de Física, Dpto. Física Experimental, Universidad Nacional Autónoma de México, Coyoacán, México, DF 04510 (Mexico); Unidad de Investigación Biomédica en Cáncer INCan-UNAM, Instituto Nacional de Cancerología, México, DF 14080 (Mexico); Heredia, Alejandro [Instituto de Ciencias Nucleares, Universidad Nacional Autónoma de México, Circuito Exterior C.U., 04510 México D.F. (Mexico); Amelines-Sarria, Oscar; Rivera, Margarita [Instituto de Física, Dpto. Materia Condensada, Universidad Nacional Autónoma de México, Coyoacán, 04510 México D.F. (Mexico); and others

    2015-03-15

    The attachment of silver nanoclusters (AgNCs) onto single-walled carbon nanotubes (SWNTs) for the formation of integrated fluorescence sites has attracted much attention due their potential applications as biological probes and nanovectors in theragnosis. Here, we report the preparation through assembly of fluorescent quasi 1-D nanomaterial based on SWNTs and silver nanoclusters (AgNCs) non-covalently attached to human serum albumin as biological linker. The fluorescent SWNT–AgNCs–HSA conjugates were characterized by atomic force microscopy, high-resolution transmission electron microscopy (HRTEM), high angle annular dark field scanning TEM (HAADF-STEM), fluorescent and UV–vis spectroscopy. The above techniques confirmed that AgNCs were non-covalently attached onto the external surface of SWNTs. In addition, it was observed that the modification did not affect the optical properties of the synthesized AgNCs since the absorption spectra and fluorescence under UV irradiation (λ = 365 nm) remain the same. The effect of the functionalized systems was tested on mammal red blood cells (RBCs) and it was found that their structural integrity was compromised by the conjugates, limiting their biological and medical applications.

  9. Detection and serotyping of dengue virus in serum samples by multiplex reverse transcriptase PCR-ligase detection reaction assay.

    Science.gov (United States)

    Das, S; Pingle, M R; Muñoz-Jordán, J; Rundell, M S; Rondini, S; Granger, K; Chang, G-J J; Kelly, E; Spier, E G; Larone, D; Spitzer, E; Barany, F; Golightly, L M

    2008-10-01

    The detection and successful typing of dengue virus (DENV) from patients with suspected dengue fever is important both for the diagnosis of the disease and for the implementation of epidemiologic control measures. A technique for the multiplex detection and typing of DENV serotypes 1 to 4 (DENV-1 to DENV-4) from clinical samples by PCR-ligase detection reaction (LDR) has been developed. A serotype-specific PCR amplifies the regions of genes C and E simultaneously. The two amplicons are targeted in a multiplex LDR, and the resultant fluorescently labeled ligation products are detected on a universal array. The assay was optimized using 38 DENV strains and was evaluated with 350 archived acute-phase serum samples. The sensitivity of the assay was 98.7%, and its specificity was 98.4%, relative to the results of real-time PCR. The detection threshold was 0.017 PFU for DENV-1, 0.004 PFU for DENV-2, 0.8 PFU for DENV-3, and 0.7 PFU for DENV-4. The assay is specific; it does not cross-react with the other flaviviruses tested (West Nile virus, St. Louis encephalitis virus, Japanese encephalitis virus, Kunjin virus, Murray Valley virus, Powassan virus, and yellow fever virus). All but 1 of 26 genotypic variants of DENV serotypes in a global DENV panel from different geographic regions were successfully identified. The PCR-LDR assay is a rapid, sensitive, specific, and high-throughput technique for the simultaneous detection of all four serotypes of DENV.

  10. MicroRNA expression in serum samples of sulfur mustard veterans as a diagnostic gateway to improve care.

    Science.gov (United States)

    Gharbi, Sedigheh; Khateri, Shahriar; Soroush, Mohammad Reza; Shamsara, Mehdi; Naeli, Parisa; Najafi, Ali; Korsching, Eberhard; Mowla, Seyed Javad

    2018-01-01

    Sulfur mustard is a vesicant chemical warfare agent, which has been used during Iraq-Iran-war. Many veterans and civilians still suffer from long-term complications of sulfur mustard exposure, especially in their lung. Although the lung lesions of these patients are similar to Chronic Obstructive Pulmonary Disease (COPD), there are some differences due to different etiology and clinical care. Less is known on the molecular mechanism of sulfur mustard patients and specific treatment options. microRNAs are master regulators of many biological pathways and proofed to be stable surrogate markers in body fluids. Based on that microRNA expression for serum samples of sulfur mustard patients were examined, to establish specific microRNA patterns as a basis for diagnostic use and insight into affected molecular pathways. Patients were categorized based on their long-term complications into three groups and microRNA serum levels were measured. The differentially regulated microRNAs and their corresponding gene targets were identified. Cell cycle arrest, ageing and TGF-beta signaling pathways showed up to be the most deregulated pathways. The candidate microRNA miR-143-3p could be validated on all individual patients. In a ROC analysis miR-143-3p turned out to be a suitable diagnostic biomarker in the mild and severe categories of patients. Further microRNAs which might own a link to the biology of the sulfur mustard patients are miR-365a-3p, miR-200a-3p, miR-663a. miR-148a-3p, which showed up only in a validation study, might be linked to the airway complications of the sulfur mustard patients. All the other candidate microRNAs do not directly link to COPD phenotype or lung complications. In summary the microRNA screening study characterizes several molecular differences in-between the clinical categories of the sulfur mustard exposure groups and established some useful microRNA biomarkers. qPCR raw data is available via the Gene Expression Omnibus https://www.ncbi

  11. Microwave-assisted headspace single-drop microextration of chlorobenzenes from water samples

    Energy Technology Data Exchange (ETDEWEB)

    Vidal, Lorena [Departamento de Quimica Analitica, Nutricion y Bromatologia, Universidad de Alicante, P.O. Box 99, E-03080 Alicante (Spain); Domini, Claudia E. [Departamento de Quimica Analitica, Nutricion y Bromatologia, Universidad de Alicante, P.O. Box 99, E-03080 Alicante (Spain); Grane, Nuria [Departamento de Quimica Analitica, Nutricion y Bromatologia, Universidad de Alicante, P.O. Box 99, E-03080 Alicante (Spain); Psillakis, Elefteria [Department of Environmental Engineering, Technical University of Crete, Polytechneioupolis, GR-73100 Chania, Crete (Greece); Canals, Antonio [Departamento de Quimica Analitica, Nutricion y Bromatologia, Universidad de Alicante, P.O. Box 99, E-03080 Alicante (Spain)]. E-mail: a.canals@ua.es

    2007-05-29

    A one-step and in-situ sample preparation method used for quantifying chlorobenzene compounds in water samples has been developed, coupling microwave and headspace single-drop microextraction (MW-HS-SDME). The chlorobenzenes in water samples were extracted directly onto an ionic liquid single-drop in headspace mode under the aid of microwave radiation. For optimization, a Plackett-Burman screening design was initially used, followed by a mixed-level factorial design. The factors considered were: drop volume, aqueous sample volume, stirring speed, ionic strength, extraction time, ionic liquid type, microwave power and length of the Y-shaped glass-tube. The optimum experimental conditions found from this statistical evaluation were: a 5 {mu}L microdrop of 1-hexyl-3-methylimidazolium hexafluorophosphate exposed for 20 min to the headspace of a 30 mL aqueous sample, irradiated by microwaves at 200 W and placed in a 50 mL spherical flask connected to a 25 cm Y-shaped glass-tube. Under the optimised experimental conditions, the response of a high performance liquid chromatographic system was found to be linear over the range studied and with correlation coefficients ranging between 0.9995 and 0.9999. The method showed a good level of repeatability, with relative standard deviations varying between 2.3 and 8.3% (n = 5). Detection limits were found in the low {mu}g L{sup -1} range varying between 0.016 and 0.039 {mu}g L{sup -1}. Overall, the performance of the proposed method demonstrated the favourable effect of microwave sample irradiation upon HS-SDME. Finally, recovery studies from different types of environmental water samples revealed that matrix had little effect upon extraction.

  12. Microwave-assisted headspace single-drop microextration of chlorobenzenes from water samples

    International Nuclear Information System (INIS)

    Vidal, Lorena; Domini, Claudia E.; Grane, Nuria; Psillakis, Elefteria; Canals, Antonio

    2007-01-01

    A one-step and in-situ sample preparation method used for quantifying chlorobenzene compounds in water samples has been developed, coupling microwave and headspace single-drop microextraction (MW-HS-SDME). The chlorobenzenes in water samples were extracted directly onto an ionic liquid single-drop in headspace mode under the aid of microwave radiation. For optimization, a Plackett-Burman screening design was initially used, followed by a mixed-level factorial design. The factors considered were: drop volume, aqueous sample volume, stirring speed, ionic strength, extraction time, ionic liquid type, microwave power and length of the Y-shaped glass-tube. The optimum experimental conditions found from this statistical evaluation were: a 5 μL microdrop of 1-hexyl-3-methylimidazolium hexafluorophosphate exposed for 20 min to the headspace of a 30 mL aqueous sample, irradiated by microwaves at 200 W and placed in a 50 mL spherical flask connected to a 25 cm Y-shaped glass-tube. Under the optimised experimental conditions, the response of a high performance liquid chromatographic system was found to be linear over the range studied and with correlation coefficients ranging between 0.9995 and 0.9999. The method showed a good level of repeatability, with relative standard deviations varying between 2.3 and 8.3% (n = 5). Detection limits were found in the low μg L -1 range varying between 0.016 and 0.039 μg L -1 . Overall, the performance of the proposed method demonstrated the favourable effect of microwave sample irradiation upon HS-SDME. Finally, recovery studies from different types of environmental water samples revealed that matrix had little effect upon extraction

  13. Detection of Janus Kinase 2 gene single point mutation in real samples with electrochemical DNA biosensor.

    Science.gov (United States)

    Topkaya, Seda Nur; Kosova, Buket; Ozsoz, Mehmet

    2014-02-15

    Janus Kinase 2 (JAK2) gene single point mutations, which have been reported to be associated with myeloproliferative disorders, are usually detected through conventional methods such as melting curve assays, allele-specific and quantitative Polymerase Chain Reactions (PCRs). Herein, an electrochemical biosensor for the detection of a Guanine (G) to Thymine (T) transversion at nucleotide position 1849 of the JAK2 gene was reported. Due to clinical importance of this mutation, easy and sensitive tests are needed to be developed. Our aim was to design a biosensor system that is capable of detecting the mutation within less than 1h with high sensitivity. For these purposes, an electrochemical sensing system was developed based on detecting hybridization. Hybridization between probe and its target and discrimination of single point mutation was investigated by monitoring guanine oxidation signals observed at +1.0 V with Differential Pulse Voltammetry (DPV) by using synthetic oligonucleotides and Polymerase Chain Reaction (PCR) amplicons. Hybridization between probe and PCR amplicons was also determined with Electrochemical Impedance Spectroscopy (EIS). We successfully detect hybridization first in synthetic samples, and ultimately in real samples involving blood samples from patients as well as additional healthy controls. The limit of detection (S/N=3) was calculated as 44 pmol of target sequence in a 40-μl reaction volume in real samples. Copyright © 2013 Elsevier B.V. All rights reserved.

  14. Serum sample levels of bromine, iron, scandium and zinc in preschool children of Atayal and Bunun aborigines living in central Taiwan

    International Nuclear Information System (INIS)

    Chien-Yi Chen; Ding-Bang Lin; Yuan-Yaw Wei

    2006-01-01

    This study determined bromine, iron, scandium and zinc serum levels in Taiwanese aboriginal preschool children living in remote mountainous areas to increase the understanding of the social, cultural, nutrient and ethnic background of the Taiwanese children. Seventy-three serum samples were taken from two ethnic groups of preschool children, Atayal aborigines (AAPC) and Bunun aborigines (BAPC). Sera of these children were freeze dried. Trace elements in sera were identified by instrumental neutron activation analysis (INAA). The accuracy and precision of INAA was evaluated using certified reference materials: Tomato Leaves (NIST-SRM 1570a) and Lichen (IAEA-336). Statistical analysis identified several different patterns for ethnic groups, gender and age via the two-tailed Student's t-test. Analytical results showed that the ranges of Br, Fe, Sc and Zn in sera were somewhat wide. The Zn serum levels (p < 0.05) and Br serum levels (p < 0.01) in the AAPC were significantly lower than those in the BAPC. However, there were no significant differences in Fe or Sc serum levels between the two groups. Analytical results were compared to published data for different counties. This study is the first investigating trace elements in Taiwanese aborigines and can be used to establish a much-needed serum element database. (author)

  15. Simple and Reproducible Sample Preparation for Single-Shot Phosphoproteomics with High Sensitivity

    DEFF Research Database (Denmark)

    Jersie-Christensen, Rosa R.; Sultan, Abida; Olsen, Jesper V

    2016-01-01

    The traditional sample preparation workflow for mass spectrometry (MS)-based phosphoproteomics is time consuming and usually requires multiple steps, e.g., lysis, protein precipitation, reduction, alkylation, digestion, fractionation, and phosphopeptide enrichment. Each step can introduce chemical...... artifacts, in vitro protein and peptide modifications, and contaminations. Those often result in sample loss and affect the sensitivity, dynamic range and accuracy of the mass spectrometric analysis. Here we describe a simple and reproducible phosphoproteomics protocol, where lysis, denaturation, reduction......, and alkylation are performed in a single step, thus reducing sample loss and increasing reproducibility. Moreover, unlike standard cell lysis procedures the cell harvesting is performed at high temperatures (99 °C) and without detergents and subsequent need for protein precipitation. Phosphopeptides are enriched...

  16. An evaluation of multiplex bead-based analysis of cytokines and soluble proteins in archived lithium heparin plasma, EDTA plasma and serum samples

    DEFF Research Database (Denmark)

    Brøndum, Line; Sørensen, Brita Singers; Eriksen, Jesper Grau

    2016-01-01

    in plasma and serum from 86 head and neck cancer patients and 33 controls were evaluated: EGFR, leptin, OPN, VEGFR-1, VEGFR-2, IL-2, IL-13, PDGF-bb, TNF, PAI-1, SDF-1a, IL-4, IL-6, IL-8, eotaxin, G-CSF, VEGF, GRO-a, and HGF. RESULTS: The correlation between measurements of the same samples analyzed...

  17. Ultratrace analysis of polychlorinated biphenyls (PCBs) and their hydroxylated metabolites (OH-PCBs) in human serum and cerebrospinal fluid (CSF) samples

    Energy Technology Data Exchange (ETDEWEB)

    Takasuga, T.; Senthilkumar, K.; Watanabe, K.; Takemori, H. [Shimadzu Techno Research, Inc., Kyoto (Japan); Shoda, T. [Ehime Univ. Medical Research Center, Matsuyama (Japan); Kuroda, Y. [Tokyo Metropolitan Inst. for Neuroscience, Tokyo (Japan)

    2004-09-15

    In the present study, we established pretreatment and high sensitivity analytical method of polychlorinated biphenyls (PCBs) and their hydroxylated metabolites (OH-PCBs) in serum and cerebrospinal fluid (CSF) of humans for the first time. Analyzing serum and CSF samples from humans found unique because PCBs behavior and metabolism could be discerned. Furthermore, so far studies reported concentrations of OH-PCBs in wildlife samples obtained by HRGC-LRMS or GC-ECD data. In this study, we established cleanup and analytical methods by high resolution gas chromatography-high resolution mass spectrometry (HRGC-HRMS) using 1 mL of sample. Mainly, total PCBs and OH-PCBs in the CSF were extracted by specialized developed method. Using this method, PCBs and OH-PCBs could be determined swiftly. Based on this method, major OH-PCB congeners were detected from human, serum, CSF, control serum and Rhesus monkey plasma. Present methodology developed based on the isotope dilution technique using OH-PCBs standard and thus we suggest the present methodology could apply for ultra trace analysis of OHPCBs as well as total PCBs in human samples.

  18. Automated column liquid chromatographic determination of amoxicillin and cefadroxil in bovine serum and muscle tissue using on-line dialysis for sample preparation

    NARCIS (Netherlands)

    Snippe, N; van de Merbel, N C; Ruiter, F P; Steijger, O M; Lingeman, H; Brinkman, U A

    1994-01-01

    A fully automated method is described for the determination of amoxicillin and cefadroxil in bovine serum and muscle tissue. The method is based on the on-line combination of dialysis and solid-phase extraction for sample preparation, and column liquid chromatography with ultraviolet detection. In

  19. Comparison of serum pools and oral fluid samples for detection of porcine circovirus type 2 by quantitative real-time PCR in finisher pigs

    DEFF Research Database (Denmark)

    Nielsen, Gitte Blach; Nielsen, Jens Peter; Haugegaard, John

    2018-01-01

    Porcine circovirus type 2 (PCV2) diagnostics in live pigs often involves pooled serum and/or oral fluid samples for group-level determination of viral load by quantitative real-time polymerase chain reaction (qPCR). The purpose of the study was to compare the PCV2 viral load determined by qPCR of...

  20. Monoclonal antibody-based dipstick assay: a reliable field applicable technique for diagnosis of Schistosoma mansoni infection using human serum and urine samples.

    Science.gov (United States)

    Demerdash, Zeinab; Mohamed, Salwa; Hendawy, Mohamed; Rabia, Ibrahim; Attia, Mohy; Shaker, Zeinab; Diab, Tarek M

    2013-02-01

    A field applicable diagnostic technique, the dipstick assay, was evaluated for its sensitivity and specificity in diagnosing human Schistosoma mansoni infection. A monoclonal antibody (mAb) against S. mansoni adult worm tegumental antigen (AWTA) was employed in dipstick and sandwich ELISA for detection of circulating schistosome antigen (CSA) in both serum and urine samples. Based on clinical and parasitological examinations, 60 S. mansoni-infected patients, 30 patients infected with parasites other than schistosomiasis, and 30 uninfected healthy individuals were selected. The sensitivity and specificity of dipstick assay in urine samples were 86.7% and 90.0%, respectively, compared to 90.0% sensitivity and 91.7% specificity of sandwich ELISA. In serum samples, the sensitivity and specificity were 88.3% and 91.7% for dipstick assay vs. 91.7% and 95.0% for sandwich ELISA, respectively. The diagnostic efficacy of dipstick assay in urine and serum samples was 88.3% and 90.0%, while it was 90.8% and 93.3% for sandwich ELISA, respectively. The diagnostic indices of dipstick assay and ELISA either in serum or in urine were statistically comparable (P>0.05). In conclusion, the dipstick assay offers an alternative simple, rapid, non-invasive technique in detecting CSA or complement to stool examinations especially in field studies.

  1. Standardizing serum 25-hydroxyvitamin D data from four Nordic population samples using the Vitamin D Standardization Program protocols: Shedding new light on vitamin D status in Nordic individuals

    DEFF Research Database (Denmark)

    Cashman, Kevin D; Dowling, Kirsten G; Škrabáková, Zuzana

    2015-01-01

    Knowledge about the distributions of serum 25-hydroxyvitamin D (25(OH)D) concentrations in representative population samples is critical for the quantification of vitamin D deficiency as well as for setting dietary reference values and food-based strategies for its prevention. Such data for the E...... standardization. In conclusion, standardization of serum 25(OH)D concentrations is absolutely necessary in order to compare serum 25(OH)D concentrations across different study populations, which is needed to quantify and prevent vitamin D deficiency.......Knowledge about the distributions of serum 25-hydroxyvitamin D (25(OH)D) concentrations in representative population samples is critical for the quantification of vitamin D deficiency as well as for setting dietary reference values and food-based strategies for its prevention. Such data...... for the European Union are of variable quality making it difficult to estimate the prevalence of vitamin D deficiency across member states. As a consequence of the widespread, method-related differences in measurements of serum 25(OH)D concentrations, the Vitamin D Standardization Program (VDSP) developed...

  2. Variation of calcium, copper and iron levels in serum, bile and stone samples of patients having different types of gallstone: A comparative study.

    Science.gov (United States)

    Khan, Mustafa; Kazi, Tasneem Gul; Afridi, Hassan Imran; Sirajuddin; Bilal, Muhammad; Akhtar, Asma; Khan, Sabir; Kadar, Salma

    2017-08-01

    Epidemiological data among the human population has shown a significantly increased incidence of gallstone (GS) disease worldwide. It was studied that some essential (calcium) and transition elements (iron and copper) in bile play an important role in the development of GS. The estimation of calcium, copper and iron were carried out in the serum, gall bladder bile and different types of GS (cholesterol, mixed and pigmented) of 172 patients, age ranged 20-55years. For comparative purpose age matched referents not suffering from GS diseases were also selected. Biliary concentrations of calcium (Ca), iron (Fe) and copper (Cu) were correlated with their concentrations in serum and different types of GS samples. The ratio of Ca, Fe and Cu in bile with serum was also calculated. Understudy metals were determined by flame atomic absorption spectroscopy after acid decomposition of matrices of selected samples. The Ca concentrations in serum samples were significantly higher in patients with pigmented GS as compared to controls (pdifference was significant for pigmented GS patients (p>0.001). The contents of Cu and Fe in serum and bile of all patients (except female cholesterol GS patient have low serum iron concentration) were found to be higher than control, but difference was significant in those patients who have pigmented GS. The concentration of Ca, Fe and Cu in different types GS were found in the order, Pigmented>mixed>cholesterol. The bile/serum ratio for Ca, Cu and Fe was found to be significantly higher in pigmented GS patients. Gall bladder bile was slightly alkaline in patients as compared to referents. The density of bile was found to be higher in patients as compared to the referents. Various functional groups present in different types of GS samples were confirmed by Fourier transform infra-red spectroscopy. The higher density and pH of bile, elevated concentrations of transition elements in all types of biological samples (serum, bile and GS), could be an

  3. Levels of (1→3-β-D-glucan, Candida mannan and Candida DNA in serum samples of pediatric cancer patients colonized with Candida species

    Directory of Open Access Journals (Sweden)

    Khan Zia U

    2010-10-01

    Full Text Available Abstract Background Surveillance cultures may be helpful in identifying patients at increased risk of developing invasive candidiasis. However, only scant information exists on the effect of Candida colonization on serum levels of diagnostic biomarkers. This prospective surveillance study determined the extent of Candida colonization among pediatric cancer patients and its possible impact on serum levels of (1-3-β-D-glucan (BDG, Candida mannan and Candida DNA. Methods A total of 1075 swabs originating from oropharynx (n = 294, nostrils (n = 600, rectum (n = 28, groin (n = 50, ear (n = 54, and axilla (n = 49 of 63 pediatric cancer patients were cultured for the isolation of Candida spp. Patients yielding Candida spp. from any sites were considered as colonized. Serum samples were collected from patients at the time of first surveillance culture for detection of BDG by Fungitell kit and Candida mannan by Platelia Candida Ag. Candida DNA was detected by using panfungal primers and identification was carried out by using species-specific primers and DNA sequencing. Results Seventy-five (7.6% swab cultures from 35 (55.5% patients yielded Candida spp. These isolates included C. albicans (n = 62, C. dubliniensis (n = 8, C. glabrata and C. tropicalis (n = 2 each and C. krusei (n = 1. Eleven patients were colonized at three or more sites. Eight of 36 serum samples from 6 colonized patients yielded BDG values higher than the currently recommended cut-off value of ≥80 pg/ml. However, none of the serum samples yielded Candida mannan levels ≥0.5 ng/ml and PCR test for Candida DNA was also negative in all the serum samples of colonized patients. During the study period, only two colonized patients subsequently developed candidemia due to C. tropicalis. Besides positive blood cultures, C. tropicalis DNA, BDG and Candida mannan were also detected in serum samples of both the patients. Conclusions The present study demonstrates that while mucosal

  4. Zooplankton diversity analysis through single-gene sequencing of a community sample

    Directory of Open Access Journals (Sweden)

    Nishida Mutsumi

    2009-09-01

    Full Text Available Abstract Background Oceans cover more than 70% of the earth's surface and are critical for the homeostasis of the environment. Among the components of the ocean ecosystem, zooplankton play vital roles in energy and matter transfer through the system. Despite their importance, understanding of zooplankton biodiversity is limited because of their fragile nature, small body size, and the large number of species from various taxonomic phyla. Here we present the results of single-gene zooplankton community analysis using a method that determines a large number of mitochondrial COI gene sequences from a bulk zooplankton sample. This approach will enable us to estimate the species richness of almost the entire zooplankton community. Results A sample was collected from a depth of 721 m to the surface in the western equatorial Pacific off Pohnpei Island, Micronesia, with a plankton net equipped with a 2-m2 mouth opening. A total of 1,336 mitochondrial COI gene sequences were determined from the cDNA library made from the sample. From the determined sequences, the occurrence of 189 species of zooplankton was estimated. BLASTN search results showed high degrees of similarity (>98% between the query and database for 10 species, including holozooplankton and merozooplankton. Conclusion In conjunction with the Census of Marine Zooplankton and Barcode of Life projects, single-gene zooplankton community analysis will be a powerful tool for estimating the species richness of zooplankton communities.

  5. Estimation of technetium 99m mercaptoacetyltriglycine plasma clearance by use of one single plasma sample

    International Nuclear Information System (INIS)

    Mueller-Suur, R.; Magnusson, G.; Karolinska Inst., Stockholm; Bois-Svensson, I.; Jansson, B.

    1991-01-01

    Recent studies have shown that technetium 99m mercaptoacetyltriglycine (MAG-3) is a suitable replacement for iodine 131 or 123 hippurate in gamma-camera renography. Also, the determination of its clearance is of value, since it correlates well with that of hippurate and thus may be an indirect measure of renal plasma flow. In order to simplify the clearance method we developed formulas for the estimation of plasma clearance of MAG-3 based on a single plasma sample and compared them with the multiple sample method based on 7 plasma samples. The correlation to effective renal plasma flow (ERPF) (according to Tauxe's method, using iodine 123 hippurate), which ranged from 75 to 654 ml/min per 1.73 m 2 , was determined in these patients. Using the developed regression equations the error of estimate for the simplified clearance method was acceptably low (18-14 ml/min), when the single plasma sample was taken 44-64 min post-injection. Formulas for different sampling times at 44, 48, 52, 56, 60 and 64 min are given, and we recommend 60 min as optimal, with an error of estimate of 15.5 ml/min. The correlation between the MAG-3 clearances and ERPF was high (r=0.90). Since normal values for MAG-3 clearance are not yet available, transformation to estimated ERPF values by the regression equation (ERPF=1.86xC MAG-3 +4.6) could be of clinical value in order to compare it with the normal values for ERPF given in the literature. (orig.)

  6. Structural and magnetic properties evolution study method using a single ribbon-shaped sample

    Science.gov (United States)

    Moya, Javier A.

    2017-06-01

    A new type of study is presented for magnetic and structural characterization of amorphous or nanocrystalline metallic alloys in ribbon or wire-shaped samples. A single sample is subjecting to successive steps of flash isocurrent heat treatments with increasing duration in time, followed by a rapid cooling, while magneto-electric properties evolution are scanned in situ at room temperature. When one set of isocurrent heat treatments is finished, the annealing current is increased and a new set of isocurrent treatments starts. The properties studied were the saturation magnetization and the coercive field at 50 Hz, magnetic permeability at 100 kHz and electrical resistance from where we also obtained the crystalline fraction. The method was applied on two samples of Finemet-like alloys and the results were analyzed from the perspective of current literature. With the present method it is possible to obtain a general and meticulous understanding of the structural and magnetic evolution of the samples tested, with a considerable saving of time and samples.

  7. Fabrication of an electrochemical nanoaptasensor based on AuNPs for ultrasensitive determination of cocaine in serum sample

    Energy Technology Data Exchange (ETDEWEB)

    Roushani, Mahmoud, E-mail: mahmoudroushani@yahoo.com; Shahdost-fard, Faezeh

    2016-04-01

    Herein we describe an ultrasensitive electrochemical nanoaptasensor for the detection of one of the most dangerous narcotic drugs available, cocaine. The nanoaptasensor was constructed by the covalent attachment of a 5′-NH{sub 2}-3′-gold nanoparticles terminated aptamer on the surface of a glassy carbon electrode which was deposited with gold nanoparticles (AuNPs/GCE). It is worth noting that the interaction of the cysteamine stable self-assembled monolayer on the AuNPs/GCE surface and the covalent attachment of terephthalaldehyde via amide coupling with the amine groups in the cysteamine and aptamer, respectively, resulted in the covalent attachment of the aptamer to AuNPs/GCE. The presence of gold nanoparticles both on surface of the glassy carbon electrode and in the end of the aptamer, can provide advantages such as increase of active surface area, high acceleration of the electron transfer and improved electrochemical signal, respectively. The decrease in the peak current of [Fe(CN){sub 6}]{sup 3−/4−} as the probe redox with increase of cocaine concentration, in differential pulse voltammetry as the measuring technique, from 5 pM up to 5 nM was linear and an unprecedented detection limit of 0.5 pM was yielded. Furthermore, the effect of some common analgesic drugs as the potential interferents were investigated and also, to evaluate practical application of the proposed nanoaptasensor human blood serum sample as a real sample was used. Simple preparation, low operation cost, speed and validity are the decisive factors of this method motivating its application to biosensing investigation. - Highlights: • An electrochemical nanoaptasensor for the detection of cocaine is presented. • An AuNPs terminated aptamer was covalent bonded on the surface of the AuNPs/GCE. • The presence of AuNPs has many advantages and improved electrochemical signal. • Two linear ranges from 5 pM up to 5 nM and an unprecedented LOD of 0.5 pM were yielded. • It will shed

  8. Fabrication of an electrochemical nanoaptasensor based on AuNPs for ultrasensitive determination of cocaine in serum sample

    International Nuclear Information System (INIS)

    Roushani, Mahmoud; Shahdost-fard, Faezeh

    2016-01-01

    Herein we describe an ultrasensitive electrochemical nanoaptasensor for the detection of one of the most dangerous narcotic drugs available, cocaine. The nanoaptasensor was constructed by the covalent attachment of a 5′-NH 2 -3′-gold nanoparticles terminated aptamer on the surface of a glassy carbon electrode which was deposited with gold nanoparticles (AuNPs/GCE). It is worth noting that the interaction of the cysteamine stable self-assembled monolayer on the AuNPs/GCE surface and the covalent attachment of terephthalaldehyde via amide coupling with the amine groups in the cysteamine and aptamer, respectively, resulted in the covalent attachment of the aptamer to AuNPs/GCE. The presence of gold nanoparticles both on surface of the glassy carbon electrode and in the end of the aptamer, can provide advantages such as increase of active surface area, high acceleration of the electron transfer and improved electrochemical signal, respectively. The decrease in the peak current of [Fe(CN) 6 ] 3−/4− as the probe redox with increase of cocaine concentration, in differential pulse voltammetry as the measuring technique, from 5 pM up to 5 nM was linear and an unprecedented detection limit of 0.5 pM was yielded. Furthermore, the effect of some common analgesic drugs as the potential interferents were investigated and also, to evaluate practical application of the proposed nanoaptasensor human blood serum sample as a real sample was used. Simple preparation, low operation cost, speed and validity are the decisive factors of this method motivating its application to biosensing investigation. - Highlights: • An electrochemical nanoaptasensor for the detection of cocaine is presented. • An AuNPs terminated aptamer was covalent bonded on the surface of the AuNPs/GCE. • The presence of AuNPs has many advantages and improved electrochemical signal. • Two linear ranges from 5 pM up to 5 nM and an unprecedented LOD of 0.5 pM were yielded. • It will shed light on new

  9. Effect of single and three months treatment with Ukrain on aminotransferases (ALT and AST) and on the serum protein level in rodents.

    Science.gov (United States)

    Jagiełło-Wójtowicz, E; Kleinrok, Z; Surmaczyńska, B; Baran, E; Feldo, M; Nowicky, J W

    1992-01-01

    The influence of Ukrain on the activity of aminotransferases (ALT and AST) and on the serum total protein content was estimated in mice and rats of both sexes receiving single or repeated doses of the drug. It was found that one hour after intraperitoneal (i.p.) administration of Ukrain no characteristic changes were recorded in the activity of the investigated enzymes, or in the serum protein content of animals of either sex. Similar effects were observed after three months treatment with Ukrain in rats of either sex. Only in mice receiving Ukrain for three months was a rise in ALT and AST activity found. No particular changes were observed in the total serum protein level, except for a small decreases in the sera of male mice.

  10. Use of cerebrospinal fluid and serum samples impregnated on FTATM Elute filter paper for the diagnosis of infections caused by Neisseria meningitidis, Streptococcus pneumoniae and Haemophilus influenzae.

    Directory of Open Access Journals (Sweden)

    Lucila Okuyama Fukasawa

    Full Text Available The lack of information regarding the burden of acute bacterial meningitis in Latin America leads to a reduction in the estimated incidence rates of the disease, and impairs public health decisions on the use and follow-up of preventive interventions, particularly, the evaluation of existing vaccination policies. The use of the real-time PCR in diagnostic routine procedures has resulted in a substantial increase in confirmed bacterial meningitis cases. However, in resource-poor countries, these assays are only available in reference laboratories. Sample transportation to these laboratories is a critical constraint, as it requires specialized, high cost courier services. To overcome this barrier we evaluated the use of FTATM Elute filter paper cards for the conservation and processing of samples under normal environmental conditions, as they would be when transported from remote and under-equipped healthcare facilities to the reference centers. A total of 401 samples received in 2015 as part of Sao Paulo's national surveillance for routine diagnosis were selected for this study.The sensitivity and specificity of real-time PCR were evaluated using fresh serum and cerebrospinal fluid (CSF samples processed using our laboratory's standard DNA extraction, and processing the same samples after being dried and stored on FTATM card, and DNA extracted following the manufacturer's instructions.The sensitivities for detection of Neisseria meningitidis, Streptococcus pneumoniae, and Haemophilus influenzae from CSF dried and stored on FTATM cards were 98%, 92%, and 100%, respectively, and with serum samples were 73%, 88%, and 100%, respectively. When compared to our laboratory's standard methodology, results showed high concordance, with Kappa index ranges of 0.9877-1.00 for CSF, and 0.8004-1.00 for serum samples.The use of FTATM cards for CSF and serum conservation and transport represents a rapid, reliable, and cost-effective alternative that will allow

  11. A Bayesian predictive sample size selection design for single-arm exploratory clinical trials.

    Science.gov (United States)

    Teramukai, Satoshi; Daimon, Takashi; Zohar, Sarah

    2012-12-30

    The aim of an exploratory clinical trial is to determine whether a new intervention is promising for further testing in confirmatory clinical trials. Most exploratory clinical trials are designed as single-arm trials using a binary outcome with or without interim monitoring for early stopping. In this context, we propose a Bayesian adaptive design denoted as predictive sample size selection design (PSSD). The design allows for sample size selection following any planned interim analyses for early stopping of a trial, together with sample size determination before starting the trial. In the PSSD, we determine the sample size using the method proposed by Sambucini (Statistics in Medicine 2008; 27:1199-1224), which adopts a predictive probability criterion with two kinds of prior distributions, that is, an 'analysis prior' used to compute posterior probabilities and a 'design prior' used to obtain prior predictive distributions. In the sample size determination of the PSSD, we provide two sample sizes, that is, N and N(max) , using two types of design priors. At each interim analysis, we calculate the predictive probabilities of achieving a successful result at the end of the trial using the analysis prior in order to stop the trial in case of low or high efficacy (Lee et al., Clinical Trials 2008; 5:93-106), and we select an optimal sample size, that is, either N or N(max) as needed, on the basis of the predictive probabilities. We investigate the operating characteristics through simulation studies, and the PSSD retrospectively applies to a lung cancer clinical trial. (243) Copyright © 2012 John Wiley & Sons, Ltd.

  12. Evaluation of heat-treating heartworm-positive canine serum samples during treatment with Advantage Multi®for Dogs and doxycycline.

    Science.gov (United States)

    Savadelis, Molly D; Roveto, Jennifer L; Ohmes, Cameon M; Hostetler, Joe A; Settje, Terry L; Dzimianski, Michael T; Moorhead, Andrew R

    2018-02-20

    The use of heat-treatment in canine and feline serum has been hypothesized to break the formation of antigen-antibody complexes, thereby freeing the heartworm antigen allowing for detection by commercially available heartworm antigen kits. While studies have analyzed the effect of heat-treating serum and plasma samples in the detection of heartworm antigen, these studies have not utilized necropsy verified results for validation. This study evaluated the use of heat-treating serum samples in experimentally infected dogs during adulticidal treatment in comparison with necropsy adult heartworm recovery. As part of a primary study, a total of 16 dogs were experimentally infected with 16 sexually mature adult heartworms using surgical transplantation, allocating 8 dogs in both the control and treated group. Treated dogs received 10 months of topical administration of Advantage Multi® for Dogs (10% Imidacloprid + 2.5% Moxidectin) every 4 weeks and 30 days of 10 mg/kg doxycycline BID. Blood samples were collected from all study animals prior to surgical transplantation of adult heartworms, on study days 0, 1, 3, 7, 14, 21, 28, and every 4 weeks thereafter for the duration of this study. Concentration of heartworm antigen was tested using the DiroCHEK® heartworm antigen test kit using serum samples both pre- and post-heat-treatment. Serum samples were heat-treated at 103 °C in a dry heat block for 10 min and centrifuging at 1818× g for 20 min. There were a total of 4 instances (days 56, 140, 224 and 252) in 3 treated dogs in which a serum sample converted from negative for the detection of heartworm antigen prior to heat-treatment to positive for the detection of heartworm antigen post-heat-treatment. At necropsy, these dogs had no adult heartworms recovered and were all negative on antigen testing prior to and after heat treatment. There was 100% accuracy in the detection of either no infection, or 1-2 adult heartworm infections using the DiroCHEK in serum

  13. Evaluation of heat-treating heartworm-positive canine serum samples during treatment with Advantage Multi® for Dogs and doxycycline

    Directory of Open Access Journals (Sweden)

    Molly D. Savadelis

    2018-02-01

    Full Text Available Abstract Background The use of heat-treatment in canine and feline serum has been hypothesized to break the formation of antigen-antibody complexes, thereby freeing the heartworm antigen allowing for detection by commercially available heartworm antigen kits. While studies have analyzed the effect of heat-treating serum and plasma samples in the detection of heartworm antigen, these studies have not utilized necropsy verified results for validation. This study evaluated the use of heat-treating serum samples in experimentally infected dogs during adulticidal treatment in comparison with necropsy adult heartworm recovery. Methods As part of a primary study, a total of 16 dogs were experimentally infected with 16 sexually mature adult heartworms using surgical transplantation, allocating 8 dogs in both the control and treated group. Treated dogs received 10 months of topical administration of Advantage Multi® for Dogs (10% Imidacloprid + 2.5% Moxidectin every 4 weeks and 30 days of 10 mg/kg doxycycline BID. Blood samples were collected from all study animals prior to surgical transplantation of adult heartworms, on study days 0, 1, 3, 7, 14, 21, 28, and every 4 weeks thereafter for the duration of this study. Concentration of heartworm antigen was tested using the DiroCHEK® heartworm antigen test kit using serum samples both pre- and post-heat-treatment. Serum samples were heat-treated at 103 °C in a dry heat block for 10 min and centrifuging at 1818× g for 20 min. Results There were a total of 4 instances (days 56, 140, 224 and 252 in 3 treated dogs in which a serum sample converted from negative for the detection of heartworm antigen prior to heat-treatment to positive for the detection of heartworm antigen post-heat-treatment. At necropsy, these dogs had no adult heartworms recovered and were all negative on antigen testing prior to and after heat treatment. There was 100% accuracy in the detection of either no infection, or 1

  14. Evaluation of nested polymerase chain reaction for the early detection of Leptospira spp. DNA in serum samples from patients with leptospirosis.

    Science.gov (United States)

    Blanco, Roberta Morozetti; Romero, Eliete Caló

    2014-04-01

    The aim of this study was to analyse the nested polymerase chain reaction (nested PCR) in human serum samples of patients with clinical manifestations of leptospirosis. The cases of leptospirosis were defined by the microagglutination test (MAT). The samples were collected in 2010. Of 1042 serum samples collected from 521 patients, 28 (5.4%) were considered positive cases of leptospirosis, and 493 (94.6%) were negative. Twenty-three confirmed cases had no MAT-detectable antibodies in the acute sample (mean of 5.6 days after onset). Nested PCR was positive in 22/23 (95.7%) patients during the acute phase of the disease, with negative results by MAT. Nested PCR was negative in all convalescent serum samples with positive results by MAT. All negative cases of leptospirosis were negative by nested PCR. The nested PCR is an alternative diagnostic tool for early detection of leptospires in sera during the first 7 days of the disease. Copyright © 2014 Elsevier Inc. All rights reserved.

  15. Prediction of two-sample 99mTc-diethylene triamine pentaacetic acid plasma clearance from single-sample method

    International Nuclear Information System (INIS)

    Zuo Li; Ma Ying-Chun; Wang Mei; Zhang Chun-Li; Wang Rong-Fu; Wang Hai-Yan

    2005-01-01

    The objective of this study was to develop an equation to predict dual plasma sample method (DPSM) 99m Tc-diethylene triamine pentaacetic acid ( 99m Tc-DTPA) plasma clearance from single plasma sample method (SPSM), and to clarify the condition in which DPSM can be substituted by SPSM in measurement of glomerular filtration rate (GFR). Patients with chronic kidney disease (CKD) were selected. Watson modified Christensen and Groth equation was used to calculate 99m Tc-DTPA plasma clearance by SPSM (sGFR). The equation recommended by the Nephrourology Committee of the Society of Nuclear Medicine was used to calculate 99m Tc-DTPA plasma clearance by DPSM (tGFR) in each patient. The difference between sGFR and tGFR was expressed as percent of the average of these two methods, and tGFR was predicted from sGFR. Plasma creatinine was measured by the kinetic picrate method, and GFR estimated by abbreviated modification of diet in renal disease (MDRD) equation (aGFR) and Cockcroft-Gault equation (cGFR) were evaluated as criteria in selection of DPSM and SPSM. Three hundred and sixty-nine patients with CKD were selected (208 male and 161 female). The average age and body weight were 51.4±15.5 years and 67.2±12.5 kg, respectively. The causes of CKD were glomerular disease, renal arterial stenosis, chronic tubulointerstitial disease, and other causes or causes unknown. The average tGFR was 62.9±36.5 ml/min/1.73 m 2 , ranging from 1-180 ml/min/1.73 m 2 . sGFR was significantly correlated with tGFR (r=0.9194, p 2 ; in contrast, then tGFR was±30 ml/min/1.73 m 2 , the difference was constant (-1.1%, 95% confidence interval -18.3%, 16.1%), and tGFR could be predicted from sGFR using the equation: predicted tGFR (ml/min/1.73 m 2 )=7 4244+0.7318 x sGFR+0.0022 x sGFR 2 (n=299, r 2 =0.9428, p 2 , the diagnostic sensitivity of a cut off value of aGFR=45 ml/min/1.73 m 2 was 91.8%, and recommended as a criterion in the selection of DPSM and SPSM. When GFR ≥30 ml/min/1.73 m 2 , t

  16. Variation in orgasm occurrence by sexual orientation in a sample of U.S. singles.

    Science.gov (United States)

    Garcia, Justin R; Lloyd, Elisabeth A; Wallen, Kim; Fisher, Helen E

    2014-11-01

    Despite recent advances in understanding orgasm variation, little is known about ways in which sexual orientation is associated with men's and women's orgasm occurrence. To assess orgasm occurrence during sexual activity across sexual orientation categories. Data were collected by Internet questionnaire from 6,151 men and women (ages 21-65+ years) as part of a nationally representative sample of single individuals in the United States. Analyses were restricted to a subsample of 2,850 singles (1,497 men, 1,353 women) who had experienced sexual activity in the past 12 months. Participants reported their sex/gender, self-identified sexual orientation (heterosexual, gay/lesbian, bisexual), and what percentage of the time they experience orgasm when having sex with a familiar partner. Mean occurrence rate for experiencing orgasm during sexual activity with a familiar partner was 62.9% among single women and 85.1% among single men, which was significantly different (F1,2848  = 370.6, P sexual orientation: heterosexual men 85.5%, gay men 84.7%, bisexual men 77.6% (F2,1494  = 2.67, P = 0.07, η(2)  = 0.004). For women, however, mean occurrence rate of orgasm varied significantly by sexual orientation: heterosexual women 61.6%, lesbian women 74.7%, bisexual women 58.0% (F2,1350  = 10.95, P sexual orientation, have less predictable, more varied orgasm experiences than do men and that for women, but not men, the likelihood of orgasm varies with sexual orientation. These findings demonstrate the need for further investigations into the comparative sexual experiences and sexual health outcomes of sexual minorities. © 2014 International Society for Sexual Medicine.

  17. Using a decline in serum hCG between days 0-4 to predict ectopic pregnancy treatment success after single-dose methotrexate: a retrospective cohort study.

    Science.gov (United States)

    Skubisz, Monika; Dutton, Philip; Duncan, William Colin; Horne, Andrew W; Tong, Stephen

    2013-02-01

    The current measure of treatment efficacy of single-dose methotrexate for ectopic pregnancy, is a fall in serum hCG of ≥15% between days 4-7 of treatment, which has a positive predictive value of 93% for treatment success. Two small studies have proposed a fall in serum hCG between days 0-4 after treatment confers similar, earlier prognostic information, with positive predictive values of 100% and 88% for treatment success. We sought to validate this in a large, independent cohort because of the potentially significant clinical implications. We conducted a retrospective study of women (n=206) treated with single-dose methotrexate for ectopic pregnancy (pre-treatment serum hCG levels ≤3000 IU/L) at Scottish hospitals between 2006-2011. Women were divided into two cohorts based on whether their serum hCG levels rose or fell between days 0-4 after methotrexate. Treatment outcomes of women in each cohort were compared, and the test performance characteristics calculated. This methodology was repeated for the current measure (≥15% fall in serum hCG between days 4-7 of treatment) and an alternate early measure (treatment), and all three measures were compared for their ability to predict medical treatment success. In our cohort, the positive predictive value of the current clinical measure was 89% (95% CI 84-94%) (121/136). A falling serum hCG between days 0-4 predicted treatment success in 85% (95% CI 79-92%) of cases (94/110) and a treatment success in 94% (95% CI 88-100%) of cases (59/63). There was no significant difference in the ability of these tests to predict medical treatment success. We have verified that a decline in serum hCG between days 0-4 after methotrexate treatment for ectopic pregnancies, with pre-treatment serum hCG levels ≤3000 IU/L, provides an early indication of likelihood of treatment success, and performs just as well as the existing measure, which only provides prognostic information on day 7.

  18. Tissue and serum samples of patients with papillary thyroid cancer with and without benign background demonstrate different altered expression of proteins

    Directory of Open Access Journals (Sweden)

    Mardiaty Iryani Abdullah

    2016-09-01

    Full Text Available Background Papillary thyroid cancer (PTC is mainly diagnosed using fine-needle aspiration biopsy. This most common form of well-differentiated thyroid cancer occurs with or without a background of benign thyroid goiter (BTG. Methods In the present study, a gel-based proteomics analysis was performed to analyse the expression of proteins in tissue and serum samples of PTC patients with (PTCb; n = 6 and without a history of BTG (PTCa; n = 8 relative to patients with BTG (n = 20. This was followed by confirmation of the levels of proteins which showed significant altered abundances of more than two-fold difference (p < 0.01 in the tissue and serum samples of the same subjects using ELISA. Results The data of our study showed that PTCa and PTCb distinguish themselves from BTG in the types of tissue and serum proteins of altered abundance. While higher levels of alpha-1 antitrypsin (A1AT and heat shock 70 kDa protein were associated with PTCa, lower levels of A1AT, protein disulfide isomerase and ubiquitin-conjugating enzyme E2 N seemed apparent in the PTCb. In case of the serum proteins, higher abundances of A1AT and alpha 1-beta glycoprotein were detected in PTCa, while PTCb was associated with enhanced apolipoprotein A-IV and alpha 2-HS glycoprotein (AHSG. The different altered expression of tissue and serum A1AT as well as serum AHSG between PTCa and PTCb patients were also validated by ELISA. Discussion The distinctive altered abundances of the tissue and serum proteins form preliminary indications that PTCa and PTCb are two distinct cancers of the thyroid that are etiologically and mechanistically different although it is currently not possible to rule out that they may also be due other reasons such as the different stages of the malignant disease. These proteins stand to have a potential use as tissue or serum biomarkers to discriminate the three different thyroid neoplasms although this requires further validation in clinically

  19. MPLEx: a Robust and Universal Protocol for Single-Sample Integrative Proteomic, Metabolomic, and Lipidomic Analyses

    Energy Technology Data Exchange (ETDEWEB)

    Nakayasu, Ernesto S.; Nicora, Carrie D.; Sims, Amy C.; Burnum-Johnson, Kristin E.; Kim, Young-Mo; Kyle, Jennifer E.; Matzke, Melissa M.; Shukla, Anil K.; Chu, Rosalie K.; Schepmoes, Athena A.; Jacobs, Jon M.; Baric, Ralph S.; Webb-Robertson, Bobbie-Jo; Smith, Richard D.; Metz, Thomas O.; Chia, Nicholas

    2016-05-03

    ABSTRACT

    Integrative multi-omics analyses can empower more effective investigation and complete understanding of complex biological systems. Despite recent advances in a range of omics analyses, multi-omic measurements of the same sample are still challenging and current methods have not been well evaluated in terms of reproducibility and broad applicability. Here we adapted a solvent-based method, widely applied for extracting lipids and metabolites, to add proteomics to mass spectrometry-based multi-omics measurements. Themetabolite,protein, andlipidextraction (MPLEx) protocol proved to be robust and applicable to a diverse set of sample types, including cell cultures, microbial communities, and tissues. To illustrate the utility of this protocol, an integrative multi-omics analysis was performed using a lung epithelial cell line infected with Middle East respiratory syndrome coronavirus, which showed the impact of this virus on the host glycolytic pathway and also suggested a role for lipids during infection. The MPLEx method is a simple, fast, and robust protocol that can be applied for integrative multi-omic measurements from diverse sample types (e.g., environmental,in vitro, and clinical).

    IMPORTANCEIn systems biology studies, the integration of multiple omics measurements (i.e., genomics, transcriptomics, proteomics, metabolomics, and lipidomics) has been shown to provide a more complete and informative view of biological pathways. Thus, the prospect of extracting different types of molecules (e.g., DNAs, RNAs, proteins, and metabolites) and performing multiple omics measurements on single samples is very attractive, but such studies are challenging due to the fact that the extraction conditions differ according to the molecule type. Here, we adapted an organic solvent-based extraction method that demonstrated

  20. Analysis of ethyl glucuronide in human serum by capillary electrophoresis with sample self-stacking and indirect detection

    Czech Academy of Sciences Publication Activity Database

    Křivánková, Ludmila; Caslavska, J.; Malášková, Hana; Gebauer, Petr; Thormann, W.

    2005-01-01

    Roč. 1081, č. 1 (2005), s. 2-8 ISSN 0021-9673 R&D Projects: GA AV ČR IAA4031401 Institutional research plan: CEZ:AV0Z40310501 Keywords : ethyl glucuronide * capillary electrophoresis * serum Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 3.096, year: 2005

  1. Single-Tube Flow Cytometry Assay for the Detection of Mature Lymphoid Neoplasms in Paucicellular Samples.

    Science.gov (United States)

    Stacchini, Alessandra; Demurtas, Anna; Aliberti, Sabrina; Barreca, Antonella; Novero, Domenico; Pacchioni, Donatella

    2016-01-01

    Flow cytometry (FC) has become a useful support for cytomorphologic evaluation (CM) of fine-needle aspirates (FNA) and serous cavity effusions (SCE) in cases of suspected non-Hodgkin lymphoma (NHL). FC results may be hampered by the scarce viability and low cellularity of the specimens. We developed a single-tube FC assay (STA) that included 10 antibodies cocktailed in 8-color labeling, a cell viability dye, and a logical gating strategy to detect NHL in hypocellular samples. The results were correlated with CM and confirmed by histologic or molecular data when available. Using the STA, we detected B-type NHL in 31 out of 103 hypocellular samples (81 FNA and 22 SCE). Of these, 8 were not confirmed by CM and 2 were considered to be only suspicious. The FC-negative samples had a final diagnosis of benign/reactive process (42/72), carcinoma (27/72), or Hodgkin lymphoma (3/72). The STA approach allowed obtainment of maximum immunophenotyping data in specimens containing a low number of cells and a large amount of debris. The information obtained by STA can help cytomorphologists not only to recognize but also to exclude malignant lymphomas. © 2016 S. Karger AG, Basel.

  2. Determination of donepezil in serum samples using molecularly imprinted polymer nanoparticles followed by high-performance liquid chromatography with ultraviolet detection.

    Science.gov (United States)

    Khansari, Mehdi Rajabnia; Bikloo, Shahrzad; Shahreza, Sara

    2016-03-01

    A molecularly imprinted polymer designed for the selective extraction of donepezil from serum samples was synthesized using a noncovalent molecular imprinting approach. The molecularly imprinted polymer was evaluated chromatographically and then its affinity for donepezil was confirmed by solid-phase extraction. The optimal conditions for solid-phase extraction were provided by cartridge conditioning using acidified water purified from a Milli-Q system, sample loading under basic aqueous conditions, clean-up using acetonitrile, and elution with methanol/tetrahydrofuran. Desirable molecular recognition properties of the molecularly imprinted polymer led to good donepezil recoveries (90-102%). The data indicated that the imprinted polymer has a perfect selectivity and affinity for donepezil and could be used for selective extraction and analysis of donepezil in human serum. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Precise simultaneous quantification of methadone and cocaine in rat serum and brain tissue samples following their successive i.p. administration.

    Science.gov (United States)

    Nakhla, David S; Hussein, Lobna A; Magdy, N; Abdallah, Inas A; Hassan, Hazem E

    2017-03-24

    A sensitive high-performance liquid chromatography (HPLC) assay with dual UV detection has been developed and validated for the simultaneous quantification of methadone and cocaine in rat serum and brain tissue samples. Liquid-liquid extraction using hexanes was applied for samples extraction with Levo-Tetrahydropalmatine (L-THP) as the internal standard. Chromatographic separation of the analytes was achieved on a reversed-phase Waters Symmetry ® C 18 column (150mm×4.6mm, 5μm). A gradient elution was employed with a mobile phase consisting of 5mM potassium phosphate containing 0.1% triethylamine (pH=6.5) (A) and acetonitrile (B) with a flow rate of 1mL/min. UV detection was employed at 215nm and 235nm for the determination of methadone and cocaine, respectively. The calibration curves were linear over the range of 0.05-10μg/mL for both methadone and cocaine. The assay was validated according to FDA guidelines for bioanalytical method validation and results were satisfactory and met FDA criteria. Inter-day accuracy values of serum and brain samples ranged from 96.97 to 105.59% while intra-day accuracy values ranged from 91.49 to 111.92%. Stability assays showed that both methadone and cocaine were stable during sample storage, preparation, and analytical procedures. The method was successfully used to analyze biological samples obtained from a drug- drug interaction pharmacokinetics (PK) study conducted in rats to investigate the effect of methadone on cocaine PK. Our method not only can be used for bioanalysis of samples obtained from rats but also can potentially be applied to human biological serum samples to monitor compliance to methadone maintenance therapy (MMT) and to detect possible cocaine-methadone co-abuse. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Estimation of 131J-Jodohippurateclearance by a simplified method using a single plasma sample

    International Nuclear Information System (INIS)

    Botsch, H.; Golde, G.; Kampf, D.

    1980-01-01

    Theoretical volumes calculated from the reciprocal of the plasma concentration of 131 J-Jodohippurate were compared in 95 patients with clearance values calculated by the 2-compartment-method and in 18 patients with conventional PAH-clearance. For estimating Hippurate-clearance from a single blood sampling the most favorable time is 45 min. after injection (r = 0.96; clearance 400/ml/min.: r = 0.98). Clearance values may be derived from the formula: C = 0.4 + 7.26 V - 0.021 x V 2 (V = injected activity/activity per l plasma taken 45 min. after injection). The simplicity, precision and reproducibility of the above mentioned clearance-method is emphasized. (orig.) [de

  5. Single-breath-hold 3-D CINE imaging of the left ventricle using Cartesian sampling.

    Science.gov (United States)

    Wetzl, Jens; Schmidt, Michaela; Pontana, François; Longère, Benjamin; Lugauer, Felix; Maier, Andreas; Hornegger, Joachim; Forman, Christoph

    2018-02-01

    Our objectives were to evaluate a single-breath-hold approach for Cartesian 3-D CINE imaging of the left ventricle with a nearly isotropic resolution of [Formula: see text] and a breath-hold duration of [Formula: see text]19 s against a standard stack of 2-D CINE slices acquired in multiple breath-holds. Validation is performed with data sets from ten healthy volunteers. A Cartesian sampling pattern based on the spiral phyllotaxis and a compressed sensing reconstruction method are proposed to allow 3-D CINE imaging with high acceleration factors. The fully integrated reconstruction uses multiple graphics processing units to speed up the reconstruction. The 2-D CINE and 3-D CINE are compared based on ventricular function parameters, contrast-to-noise ratio and edge sharpness measurements. Visual comparisons of corresponding short-axis slices of 2-D and 3-D CINE show an excellent match, while 3-D CINE also allows reformatting to other orientations. Ventricular function parameters do not significantly differ from values based on 2-D CINE imaging. Reconstruction times are below 4 min. We demonstrate single-breath-hold 3-D CINE imaging in volunteers and three example patient cases, which features fast reconstruction and allows reformatting to arbitrary orientations.

  6. Single cell PCR amplification of diatoms using fresh and preserved samples

    Science.gov (United States)

    Hamilton, Paul B.; Lefebvre, Keely E.; Bull, Roger D.

    2015-01-01

    Single cell Chelex® DNA extraction and nested PCR amplification were used to examine partial gene sequences from natural diatom populations for taxonomic and phylogenetic studies at and above the level of species. DNA was extracted from cells that were either fresh collected or stored in RNAlater. Extractions from Lugol's fixation were also attempted with limited success. Three partial gene sequences (rbcL, 18S, and psbA) were recovered using existing and new primers with a nested or double nested PCR approach with amplification and success rates between 70 and 96%. An rbcL consensus tree grouped morphologically similar specimens and was consistent across the two primary sample treatments: fresh and RNAlater. This tool will greatly enhance the number of microscopic diatom taxa (and potentially other microbes) available for barcoding and phylogenetic studies. The near-term increase in sequence data for diatoms generated via routine single cell extractions and PCR will act as a multiproxy validation of longer-term next generation genomics. PMID:26528252

  7. Brief communication: Is variation in the cranial capacity of the Dmanisi sample too high to be from a single species?

    Science.gov (United States)

    Lee, Sang-Hee

    2005-07-01

    This study uses data resampling to test the null hypothesis that the degree of variation in the cranial capacity of the Dmanisi hominid sample is within the range variation of a single species. The statistical significance of the variation in the Dmanisi sample is examined using simulated distributions based on comparative samples of modern humans, chimpanzees, and gorillas. Results show that it is unlikely to find the maximum difference observed in the Dmanisi sample in distributions of female-female pairs from comparative single-species samples. Given that two sexes are represented, the difference in the Dmanisi sample is not enough to reject the null hypothesis of a single species. Results of this study suggest no compelling reason to invoke multiple taxa to explain variation in the cranial capacity of the Dmanisi hominids. (c) 2004 Wiley-Liss, Inc

  8. Serum insulin like growth factor-1 is associated with working memory, executive function and selective attention in a sample of healthy, fit older adults.

    Science.gov (United States)

    Bellar, D; Glickman, E L; Juvancic-Heltzel, J; Gunstad, J

    2011-03-31

    The present study examined the association between serum insulin like growth factor-1 (IGF-1) concentrations and cognitive function in a sample of healthy, fit older adults (age: 70.8±9.3 years, body mass index (BMI): 27.3±5.7). Participants reported to the laboratory and basic anthropometric data were collected, followed by a fasted blood draw to quantify serum IGF-1. Participants then underwent cognitive testing that included the Mini-Mental Status Exam (MMSE), Trail Making Test A and B, Ruff's 2 and 7 test of selective attention and Letter Number Sequencing. Results showed the participants were generally cognitively intact (MMSE 27.6±1.8). Significant partial correlations (controlled for age, gender and years of education) emerged between serum IGF-1 concentrations and the total (r=0.381, P=0.030) and longest trial (r=0.455, P=0.011) on Letter Number Sequencing. Similar partial correlations yielded significant relationships between serum IGF-1 and Ruff's Automatic Detection Errors (r=-0.495, P=0.006), Controlled Speed Errors (r=-0.598, P=0.002) and errors made on the Trial Making Test part B (r=-0.466, P=0.010). These findings suggest that fasting levels of serum IGF-1 are related to higher levels of cognitive performance in healthy older adults, including working memory, selective attention and executive function. Further work is needed to more clearly determine possible mechanisms. Copyright © 2011 IBRO. Published by Elsevier Ltd. All rights reserved.

  9. Ultrasonic energy enhanced the efficiency of advance extraction methodology for enrichment of trace level of copper in serum samples of patients having neurological disorders.

    Science.gov (United States)

    Arain, Mariam S; Kazi, Tasneem G; Afridi, Hassan I; Ali, Jamshed; Akhtar, Asma

    2017-07-01

    An innovative dual dispersive ionic liquid based on ultrasound assisted microextraction (UDIL-μE), for the enrichment of trace levels of copper ion (Cu 2+ ), in serum (blood) of patients suffering from different neurological disorders. The enriched metal ions were subjected to flame atomic absorption spectrometry (FAAS). In the UDIL-μE method, the extraction solvent, ionic liquid, 1-butyl-3-methylimidazolium hexafluorophosphate [C 4 mim][PF 6 ], was dispersed into the aqueous samples using an ultrasonic bath. The(PAN) 1-(2-pyridylazo)-2-naphthol was used as ligand for the complexation of Cu ion in IL (as extracting solvent). The various variables such as sonication time, pH, concentration of complexing agent, time and rate of centrifugation, IL volume that affect the extraction process were optimized. The enhancement factor (EF) and detection limit (LOD) was found under favorable condition was 31 and 0.36μgL -1 , respectively. Reliability of the proposed method was checked by relative standard deviation (%RSD), which was found to be ion in blood serum of different neurological disorders subjects and referents of same age group. It was observed that the levels of Cu ion was two folds higher in serum samples of neurological disorders patients as related to normal referents of same age group. Copyright © 2016. Published by Elsevier B.V.

  10. Single sample expression-anchored mechanisms predict survival in head and neck cancer.

    Directory of Open Access Journals (Sweden)

    Xinan Yang

    2012-01-01

    Full Text Available Gene expression signatures that are predictive of therapeutic response or prognosis are increasingly useful in clinical care; however, mechanistic (and intuitive interpretation of expression arrays remains an unmet challenge. Additionally, there is surprisingly little gene overlap among distinct clinically validated expression signatures. These "causality challenges" hinder the adoption of signatures as compared to functionally well-characterized single gene biomarkers. To increase the utility of multi-gene signatures in survival studies, we developed a novel approach to generate "personal mechanism signatures" of molecular pathways and functions from gene expression arrays. FAIME, the Functional Analysis of Individual Microarray Expression, computes mechanism scores using rank-weighted gene expression of an individual sample. By comparing head and neck squamous cell carcinoma (HNSCC samples with non-tumor control tissues, the precision and recall of deregulated FAIME-derived mechanisms of pathways and molecular functions are comparable to those produced by conventional cohort-wide methods (e.g. GSEA. The overlap of "Oncogenic FAIME Features of HNSCC" (statistically significant and differentially regulated FAIME-derived genesets representing GO functions or KEGG pathways derived from HNSCC tissue among three distinct HNSCC datasets (pathways:46%, p<0.001 is more significant than the gene overlap (genes:4%. These Oncogenic FAIME Features of HNSCC can accurately discriminate tumors from control tissues in two additional HNSCC datasets (n = 35 and 91, F-accuracy = 100% and 97%, empirical p<0.001, area under the receiver operating characteristic curves = 99% and 92%, and stratify recurrence-free survival in patients from two independent studies (p = 0.0018 and p = 0.032, log-rank. Previous approaches depending on group assignment of individual samples before selecting features or learning a classifier are limited by design to

  11. Molecular detection of Borrelia bissettii DNA in serum samples from patients in the Czech Republic with suspected borreliosis

    Czech Academy of Sciences Publication Activity Database

    Rudenko, Natalia; Golovchenko, Maryna; Růžek, Daniel; Piskunova, N.; Mallátová, N.; Grubhoffer, Libor

    2009-01-01

    Roč. 292, č. 2 (2009), s. 274-281 ISSN 0378-1097 R&D Projects: GA MŠk(CZ) LC06009; GA ČR GD524/03/H133; GA ČR(CZ) GA524/06/1479 Institutional research plan: CEZ:AV0Z60220518 Keywords : Borrelia bissettii in human serum * causative agent * co-infection * co-detection of different species * phylogenetic analysis Subject RIV: GJ - Animal Vermins ; Diseases, Veterinary Medicine Impact factor: 2.199, year: 2009

  12. serum albumin, creatinine, uric acid and hypertensive disorders of ...

    African Journals Online (AJOL)

    hi-tech

    2003-08-08

    Aug 8, 2003 ... pregnancy using single estimation of serum protein, creatinine and uric in serum samples of healthy primigravidae with singleton pregnancy. ... developing the disease early in pregnancy. This is because ... as hypertension, diabetes mellitus or renal disease and drug use. This was followed by a complete ...

  13. Gold-FISH: A correlative approach to microscopic imaging of single microbial cells in environmental samples

    Science.gov (United States)

    Schmidt, Hannes; Seki, David; Woebken, Dagmar; Eickhorst, Thilo

    2017-04-01

    Fluorescence in situ hybridization (FISH) is routinely used for the phylogenetic identification, detection, and quantification of single microbial cells environmental microbiology. Oligonucleotide probes that match the 16S rRNA sequence of target organisms are generally applied and the resulting signals are visualized via fluorescence microscopy. Consequently, the detection of the microbial cells of interest is limited by the resolution and the sensitivity of light microscopy where objects smaller than 0.2 µm can hardly be represented. Visualizing microbial cells at magnifications beyond light microscopy, however, can provide information on the composition and potential complexity of microbial habitats - the actual sites of nutrient cycling in soil and sediments. We present a recently developed technique that combines (1) the phylogenetic identification and detection of individual microorganisms by epifluorescence microscopy, with (2) the in situ localization of gold-labelled target cells on an ultrastructural level by SEM. Based on 16S rRNA targeted in situ hybridization combined with catalyzed reporter deposition, a streptavidin conjugate labeled with a fluorescent dye and nanogold particles is introduced into whole microbial cells. A two-step visualization process including an autometallographic enhancement of nanogold particles then allows for either fluorescence or electron microscopy, or a correlative application thereof. We will present applications of the Gold-FISH protocol to samples of marine sediments, agricultural soils, and plant roots. The detection and enumeration of bacterial cells in soil and sediment samples was comparable to CARD-FISH applications via fluorescence microscopy. Examples of microbe-surface interaction analysis will be presented on the basis of bacteria colonizing the rhizoplane of rice roots. In principle, Gold-FISH can be performed on any material to give a snapshot of microbe-surface interactions and provides a promising tool for

  14. Serum Uric Acid, Kidney Function and Acute Ischemic Stroke Outcomes in Elderly Patients: A Single-Cohort, Perspective Study

    OpenAIRE

    Falsetti, Lorenzo; Capeci, William; Tarquinio, Nicola; Viticchi, Giovanna; Silvestrini, Mauro; Catozzo, Vania; Fioranelli, Agnese; Buratti, Laura; Pellegrini, Francesco

    2017-01-01

    Chronic kidney disease and hyperuricemia have been associated to an increased risk and a worse prognosis in acute ischemic stroke. Several mechanisms, including platelet dysfunction, coagulation disorders, endothelial dysfunction, inflammation, and an increased risk of atrial fibrillation could be implicated. The role of serum uric acid in this setting is still object of debate. We enrolled all the consecutive patients admitted to our department for acute ischemic stroke. Cox regression analy...

  15. Anti-Taenia solium metacestode IgG antibodies in serum samples from inhabitants of a central-western region of Brazil

    Directory of Open Access Journals (Sweden)

    Oliveira Heliana B. de

    2006-01-01

    Full Text Available A total of 354 serum samples from inhabitants who frequent the Clinical Laboratory in Catalão, Goiás, in the central-western region of Brazil, were collected from June to August, 2002. The samples were evaluated by indirect immunofluorescence antibody tests and an enzyme linked immunosorbent assay in order to detect anti-Taenia solium metacestode IgG antibodies. Reactive and inconclusive samples were tested by Western blotting (WB. Considering WB as a confirmation, the frequency of antibodies in the serum samples of the above population was 11.3% (CI 5.09 - 17.51. The immunodominant bands most frequently recognized in WB were 64-68 kDa (97.5% and 47-52 kDa (80%. The percentage of seropositivity to cysticercosis was significantly higher for individuals residing in areas without sewage systems (p < 0.0001. In conclusion, the results indicate a probable endemic situation of cysticercosis in this population. These results reinforce the urgent need for control and prevention measures to be taken by the local public health services.

  16. Acute effects of a single warm-water bath on serum adiponectin and leptin levels in healthy men: A pilot study

    Science.gov (United States)

    Shimodozono, Megumi; Matsumoto, Shuji; Ninomiya, Koji; Miyata, Ryuji; Ogata, Atsuko; Etoh, Seiji; Watanabe, Satoshi; Kawahira, Kazumi

    2012-09-01

    To preliminarily assess the acute effects of a single warm -water bath (WWB) on serum adipokine activity, we measured serum adiponectin, leptin and other metabolic profiles before, immediately after and 30 minutes after WWB in seven healthy male volunteers (mean age, 39.7 ± 6.0 years; mean body mass index, 21.6 ± 1.8 kg/m2). The subjects were immersed in tap water at 41°C for 10 minutes. Two weeks later, the same subjects underwent a single WWB with a bath additive that included inorganic salts and carbon dioxide (WWB with ISCO2) by the same protocol as for the first WWB. Leptin levels significantly increased immediately after WWB with tap water and ISCO2 (both P hemoglobin and hematocrit significantly increased immediately after WWB with tap water or ISCO2 (all P < 0.05), but they all returned to the baseline levels 30 minutes after bathing under both conditions. The sublingual temperature rose significantly after 10 minutes of WWB with tap water (0.96 ± 0.16°C relative to baseline, P < 0.01) and after the same duration of WWB with ISCO2 (1.24 ± 0.34°C relative to baseline, P < 0.01). These findings suggest that a single WWB at 41°C for 10 minutes may modulate leptin and adiponectin profiles in healthy men.

  17. A new method for the determination of benzophenone-UV filters in human serum samples by dispersive liquid-liquid microextraction with liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Vela-Soria, F; Ballesteros, O; Zafra-Gómez, A; Ballesteros, L; Navalón, A

    2014-04-01

    Benzophenone-UV filters (BP-UV filters) are extensively used in cosmetics products to avoid damaging effects of UV radiation. Despite their low toxicity, many research papers indicate that BP-UV filters are weak endocrine disruptors (EDCs). There are clear relationships between BP-UV filters exposure and several health disorders such as carcinogenesis and malformations observed in animals. In the present work, a new sample treatment procedure by dispersive liquid-liquid microextraction (DLLME) is proposed for the extraction of six BPs, namely benzophenone-1 (BP-1), benzophenone-2 (BP-2), benzophenone-3 (BP-3), benzophenone-6 (BP-6), benzophenone-8 (BP-8) and 4-hydroxybenzophenone (4-OH-BP), in human serum samples, followed by ultra-high performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) analysis. The method involves an enzymatic treatment to quantify the total content (free plus conjugated species) of BP-UV filters in serum. The extraction parameters were accurately optimized using multivariate optimization approach. Benzophenone-d₁₀ (BP-d₁₀) was used as surrogate. Limits of quantification (LOQs) ranged from 0.4 to 0.9 ng mL(-1) and inter-day precision (evaluated as relative standard deviation) ranged from 1.9% to 13.1%. The method was validated using matrix-matched calibration and a recovery assay. Recovery rates for spiked samples ranged from 97% to 106%, and acceptable linearity was obtained up to concentrations of 40 ng mL(-1). The method was applied to the determination of the target compounds in human serum samples from 20 randomly selected anonymous individuals. Copyright © 2013 Elsevier B.V. All rights reserved.

  18. Area G perimeter surface-soil and single-stage water sampling: Environmental surveillance for fiscal year 95. Progress report

    Energy Technology Data Exchange (ETDEWEB)

    Childs, M.; Conrad, R.

    1997-09-01

    ESH-19 personnel collected soil and single-stage water samples around the perimeter of Area G at Los Alamos National Laboratory (LANL) during FY 95 to characterize possible radionuclide movement out of Area G through surface water and entrained sediment runoff. Soil samples were analyzed for tritium, total uranium, isotopic plutonium, americium-241, and cesium-137. The single-stage water samples were analyzed for tritium and plutonium isotopes. All radiochemical data was compared with analogous samples collected during FY 93 and 94 and reported in LA-12986 and LA-13165-PR. Six surface soils were also submitted for metal analyses. These data were included with similar data generated for soil samples collected during FY 94 and compared with metals in background samples collected at the Area G expansion area.

  19. Identification of extracellular miRNA in archived serum samples by next-generation sequencing from RNA extracted using multiple methods.

    Science.gov (United States)

    Gautam, Aarti; Kumar, Raina; Dimitrov, George; Hoke, Allison; Hammamieh, Rasha; Jett, Marti

    2016-10-01

    miRNAs act as important regulators of gene expression by promoting mRNA degradation or by attenuating protein translation. Since miRNAs are stably expressed in bodily fluids, there is growing interest in profiling these miRNAs, as it is minimally invasive and cost-effective as a diagnostic matrix. A technical hurdle in studying miRNA dynamics is the ability to reliably extract miRNA as small sample volumes and low RNA abundance create challenges for extraction and downstream applications. The purpose of this study was to develop a pipeline for the recovery of miRNA using small volumes of archived serum samples. The RNA was extracted employing several widely utilized RNA isolation kits/methods with and without addition of a carrier. The small RNA library preparation was carried out using Illumina TruSeq small RNA kit and sequencing was carried out using Illumina platform. A fraction of five microliters of total RNA was used for library preparation as quantification is below the detection limit. We were able to profile miRNA levels in serum from all the methods tested. We found out that addition of nucleic acid based carrier molecules had higher numbers of processed reads but it did not enhance the mapping of any miRBase annotated sequences. However, some of the extraction procedures offer certain advantages: RNA extracted by TRIzol seemed to align to the miRBase best; extractions using TRIzol with carrier yielded higher miRNA-to-small RNA ratios. Nuclease free glycogen can be carrier of choice for miRNA sequencing. Our findings illustrate that miRNA extraction and quantification is influenced by the choice of methodologies. Addition of nucleic acid- based carrier molecules during extraction procedure is not a good choice when assaying miRNA using sequencing. The careful selection of an extraction method permits the archived serum samples to become valuable resources for high-throughput applications.

  20. Accurate Determination of Amino Acids in Serum Samples by Liquid Chromatography-Tandem Mass Spectrometry Using a Stable Isotope Labeling Strategy.

    Science.gov (United States)

    Song, Cuihua; Zhang, Shijuan; Ji, Zhongyin; Li, Yipeng; You, Jinmao

    2015-10-01

    An accurate and sensitive liquid chromatography-tandem mass spectrometry method was developed for the analysis of amino acids (isoleucine, leucine, valine, tyrosine, phenylalanine and tryptophan) in serum samples using a stable isotope labeling strategy. Amino acid samples and standards were, respectively, derivatized by 10-methyl-acridone-2-sulfonyl chloride (d0-MASC) and its deuterated counterpart d3-MASC to form isotopic pairs which co-eluted and were detected by an MS detector at the same time. Accurate internal standard-based quantification was thereby achieved without the use of any internal standard analogy. The labeling reaction of MASC with amino acids is fast, simple and robust. Besides, derivatization increased the molecular weight of amino acids, and therefore they were shifted out of the background noise which was often observed in low mass region. The instrument LODs were in the range of 1.0-2.5 nmol/L. Linearities calculated by comparing theoretical peak area ratios of d0-/d3-MASC derivatives with the experimental peak area ratios were excellent with correlation coefficients of >0.995. The proposed method was successfully applied to the analysis of amino acids in serum samples with high sensitivity and accuracy. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  1. Distribution of total serum IgE and specific IgE to common aeroallergens by sex and age, and their relationship to each other in a random sample of the Dutch general population aged 20-70 years

    NARCIS (Netherlands)

    Kerkhof, M; Droste, JHJ; deMonchy, JGR; Schouten, JP; Rijcken, B

    1996-01-01

    To describe the distribution of serum total IgE and specific IgE to common aeroallergens by sex and age and to study their relationship to each other, we measured serum total IgE and specific IgE (CAP) to house-dust mile, timothy grass, cat, birch, and Cladosporium in a random sample of 2496

  2. Sampling

    CERN Document Server

    Thompson, Steven K

    2012-01-01

    Praise for the Second Edition "This book has never had a competitor. It is the only book that takes a broad approach to sampling . . . any good personal statistics library should include a copy of this book." —Technometrics "Well-written . . . an excellent book on an important subject. Highly recommended." —Choice "An ideal reference for scientific researchers and other professionals who use sampling." —Zentralblatt Math Features new developments in the field combined with all aspects of obtaining, interpreting, and using sample data Sampling provides an up-to-date treat

  3. [Trend of the selenium supply of cattle in Germany, Austria, Switzerland, and Denmark. Retrospective analysis of serum samples of the years 2006-2015].

    Science.gov (United States)

    Müller, A; Freude, B

    2016-01-01

    An optimal selenium supply of cattle is essential, because an insufficiency can lead to health disorders and reduced performance. The aim of the study was to retrospectively evaluate the selenium supply of cattle in Germany, Austria, Switzerland, and Denmark. Serum samples from 45  068 cattle with unknown clinical status originating from countries all across Europe, which had been sent by veterinarians to the IDEXX Laboratory Ludwigsburg, Germany, between January 1st, 2006 and June 30th, 2015, were routinely analyzed for the selenium concentration by means of Inductively Coupled Plasma Mass Spectrometry. A total of 40  949 samples (30  462 from Germany, 4004 from Austria, 3232 from Switzerland, 3251 from Denmark) were included in the evaluation. Results were categorized as follows: 50-150 µg/l: sufficient supply,  150 µg/l: supply too high. During the observation period, a generalized trend towards a decreasing selenium supply was clear. Denmark showed the best selenium supply (77.4% of samples indicating a sufficient supply); however, even in this country a tendency towards a deterioration was seen. A very poor situation with a strongly decreasing selenium supply was observed in Austria, followed by Germany (38% and 30% of samples, respectively, indicating an undersupply). For Switzerland, a constantly poor selenium supply was found (49% of samples indicating an undersupply). Due to the ongoing trend of a selenium undersupply in cattle herds, it is recommended to control the serum selenium concentration annually and supplement this trace element via mineral food when necessary.

  4. An optical sensor for the determination of digoxin in serum samples based on a molecularly imprinted polymer membrane

    Energy Technology Data Exchange (ETDEWEB)

    Paniagua Gonzalez, Gema [Departamento de Ciencias Analiticas, Facultad de Ciencias, Universidad Nacional de Educacion a Distancia (UNED), 28040 Madrid (Spain); Fernandez Hernando, Pilar, E-mail: pfhernando@ccia.uned.es [Departamento de Ciencias Analiticas, Facultad de Ciencias, Universidad Nacional de Educacion a Distancia (UNED), 28040 Madrid (Spain); Durand Alegria, J. S. [Departamento de Ciencias Analiticas, Facultad de Ciencias, Universidad Nacional de Educacion a Distancia (UNED), 28040 Madrid (Spain)

    2009-04-13

    This paper reports the synthesis and testing of a molecularly imprinted polymer membrane for digoxin analysis. Digoxin-specific bulk polymer was obtained by the UV initiated co-polymerisation of methacrylic acid and ethylene glycol dimethacrylate in acetonitrile as porogen. After extracting the template analyte, the ground polymer particles were mixed with plasticizer polyvinyl chloride to form a MIP membrane. A reference polymer membrane was prepared from the same mixture of monomers but with no template. The resultant membrane morphologies were examined by scanning electron microscopy. The imprinted membrane was tested as the recognition element in a digoxin-sensitive fluorescence sensor; sensor response was measured using standard solutions of digoxin at concentrations of up to 4 x 10{sup -3} mg L{sup -1}. The detection limit was 3.17 x 10{sup -5} mg L{sup -1}. Within- and between-day relative standard deviations RSD (n = 5) were in the range 4.5-5.5% and 5.5-6.5% respectively for 0 and 1 x 10{sup -3} mg L{sup -1} digoxin concentrations. A selectivity study showed that compounds of similar structure to digoxin did not significantly interfere with detection for interferent concentrations at 10, 30 and 100 times higher than the digoxin concentration. This simply manufactured MIP membrane showed good recognition characteristics, a high affinity for digoxin, and provided satisfactory results in analyses of this analyte in human serum.

  5. An optical sensor for the determination of digoxin in serum samples based on a molecularly imprinted polymer membrane

    International Nuclear Information System (INIS)

    Paniagua Gonzalez, Gema; Fernandez Hernando, Pilar; Durand Alegria, J. S.

    2009-01-01

    This paper reports the synthesis and testing of a molecularly imprinted polymer membrane for digoxin analysis. Digoxin-specific bulk polymer was obtained by the UV initiated co-polymerisation of methacrylic acid and ethylene glycol dimethacrylate in acetonitrile as porogen. After extracting the template analyte, the ground polymer particles were mixed with plasticizer polyvinyl chloride to form a MIP membrane. A reference polymer membrane was prepared from the same mixture of monomers but with no template. The resultant membrane morphologies were examined by scanning electron microscopy. The imprinted membrane was tested as the recognition element in a digoxin-sensitive fluorescence sensor; sensor response was measured using standard solutions of digoxin at concentrations of up to 4 x 10 -3 mg L -1 . The detection limit was 3.17 x 10 -5 mg L -1 . Within- and between-day relative standard deviations RSD (n = 5) were in the range 4.5-5.5% and 5.5-6.5% respectively for 0 and 1 x 10 -3 mg L -1 digoxin concentrations. A selectivity study showed that compounds of similar structure to digoxin did not significantly interfere with detection for interferent concentrations at 10, 30 and 100 times higher than the digoxin concentration. This simply manufactured MIP membrane showed good recognition characteristics, a high affinity for digoxin, and provided satisfactory results in analyses of this analyte in human serum.

  6. Versatile lipid profiling by liquid chromatography–high resolution mass spectrometry using all ion fragmentation and polarity switching. Preliminary application for serum samples phenotyping related to canine mammary cancer

    Energy Technology Data Exchange (ETDEWEB)

    Gallart-Ayala, H., E-mail: laberca@oniris-nantes.fr [LUNAM, Ecole Nationale Vétérinaire, Agroalimentaire et de l’Alimentation Nantes Atlantique (Oniris), USC 1329 INRA Laboratoire d’Etude des résidus et Contaminants dans les Aliments (LABERCA), Site de la Chantrerie – CS50707, 44307 Nantes cedex 3 (France); Courant, F.; Severe, S.; Antignac, J.-P. [LUNAM, Ecole Nationale Vétérinaire, Agroalimentaire et de l’Alimentation Nantes Atlantique (Oniris), USC 1329 INRA Laboratoire d’Etude des résidus et Contaminants dans les Aliments (LABERCA), Site de la Chantrerie – CS50707, 44307 Nantes cedex 3 (France); Morio, F.; Abadie, J. [LUNAM, Ecole Nationale Vétérinaire, Agroalimentaire et de l’Alimentation Nantes Atlantique (Oniris), Cancers Animaux, Modèles pour la Recherche en Oncologie Comparée (AMaROC), Site de la Chantrerie–CS50707, 44307 Nantes cedex 3 (France); Le Bizec, B. [LUNAM, Ecole Nationale Vétérinaire, Agroalimentaire et de l’Alimentation Nantes Atlantique (Oniris), USC 1329 INRA Laboratoire d’Etude des résidus et Contaminants dans les Aliments (LABERCA), Site de la Chantrerie – CS50707, 44307 Nantes cedex 3 (France)

    2013-09-24

    Graphical abstract: -- Highlights: •Lipidomics, high resolution mass spectrometry, polarity switching, serum, canine mammary cancer. -- Abstract: Lipids represent an extended class of substances characterized by such high variety and complexity that makes their unified analyses by liquid chromatography coupled to either high resolution or tandem mass spectrometry (LC–HRMS or LC–MS/MS) a real challenge. In the present study, a new versatile methodology associating ultra high performance liquid chromatography coupled to high resolution tandem mass spectrometry (UHPLC–HRMS/MS) have been developed for a comprehensive analysis of lipids. The use of polarity switching and “all ion fragmentation” (AIF) have been two action levels particularly exploited to finally permit the detection and identification of a multi-class and multi-analyte extended range of lipids in a single run. For identification purposes, both higher energy collision dissociation (HCD) and in-source CID (collision induced dissociation) fragmentation were evaluated in order to obtain information about the precursor and product ions in the same spectra. This approach provides both class-specific and lipid-specific fragments, enhancing lipid identification. Finally, the developed method was applied for differential phenotyping of serum samples collected from pet dogs developing spontaneous malignant mammary tumors and health controls. A biological signature associated with the presence of cancer was then successfully revealed from this lipidome analysis, which required to be further investigated and confirmed at larger scale.

  7. Serum iron test

    Science.gov (United States)

    Fe+2; Ferric ion; Fe++; Ferrous ion; Iron - serum; Anemia - serum iron; Hemochromatosis - serum iron ... A blood sample is needed. Iron levels are highest in the morning. Your health care provider will likely have you do this test in the morning.

  8. Detection and mapping of Cannabinoids in single hair samples through rapid derivatization- Matrix-Assisted Laser Desorption Ionization Mass Spectrometry

    OpenAIRE

    Beasley, Emma; Francese, Simona; Bassindale, Thomas

    2016-01-01

    The sample preparation method reported in this work has permitted for the first time the application of Matrix Assisted Laser Desorption Ionization Mass Spectrometry Profiling and Imaging (MALDI-MSP and MALDI-MSI) for the detection and mapping of cannabinoids in a single hair sample. MALDI-MSI analysis of hair samples has recently been suggested as an alternative technique to traditional methods of GC-MS and LC-MS due to simpler sample preparation, the ability to detect a narrower time frame ...

  9. A competitive immunoassay for ultrasensitive detection of Hg{sup 2+} in water, human serum and urine samples using immunochromatographic test based on surface-enhanced Raman scattering

    Energy Technology Data Exchange (ETDEWEB)

    She, Pei; Chu, Yanxin [The Key Lab of Health Chemistry & Molecular Diagnosis of Suzhou, College of Chemistry, Chemical Engineering & Materials Science, Soochow University, Renai Road 199, Suzhou 215123 (China); Liu, Chunwei; Guo, Xun [OptoTrace (Suzhou) Technologies, Inc., STE 316, Building 4, No. 218, Xinghu Street, bioBAY, Suzhou Industrial Park, Suzhou 215123 (China); Zhao, Kang [The Key Lab of Health Chemistry & Molecular Diagnosis of Suzhou, College of Chemistry, Chemical Engineering & Materials Science, Soochow University, Renai Road 199, Suzhou 215123 (China); Li, Jianguo, E-mail: lijgsd@suda.edu.cn [The Key Lab of Health Chemistry & Molecular Diagnosis of Suzhou, College of Chemistry, Chemical Engineering & Materials Science, Soochow University, Renai Road 199, Suzhou 215123 (China); Du, Haijing; Zhang, Xiang [The Key Lab of Health Chemistry & Molecular Diagnosis of Suzhou, College of Chemistry, Chemical Engineering & Materials Science, Soochow University, Renai Road 199, Suzhou 215123 (China); Wang, Hong [OptoTrace (Suzhou) Technologies, Inc., STE 316, Building 4, No. 218, Xinghu Street, bioBAY, Suzhou Industrial Park, Suzhou 215123 (China); Deng, Anping, E-mail: denganping@suda.edu.cn [The Key Lab of Health Chemistry & Molecular Diagnosis of Suzhou, College of Chemistry, Chemical Engineering & Materials Science, Soochow University, Renai Road 199, Suzhou 215123 (China)

    2016-02-04

    An immunochromatographic test (ICT) strip was developed for ultrasensitive competitive immunoassay of Hg{sup 2+}. This strategy was achieved by combining the easy-operation and rapidity of ICT with the high sensitivity of surface-enhanced Raman scattering (SERS). Monoclonal antibody (mAb) against Hg{sup 2+} and Raman active substance 4-mercaptobenzoic acid (MBA) dual labelled gold nanoparticles (GNPs) were prepared as an immunoprobe. The Raman scattering intensity of MBA on the test line of the ICT strip was measured for quantitative determination of Hg{sup 2+}. The ICT was able to directly detect Hg{sup 2+} without complexing due to the specific recognition of the mAb with Hg{sup 2+}. The IC{sub 50} and limit of detection (LOD) of the assay for Hg{sup 2+} detection were 0.12 ng mL{sup −1} and 0.45 pg mL{sup −1}, respectively. There was no cross-reactivity (CR) of the assay with other nineteen ions and the ICT strips could be kept for 5 weeks without loss of activity. The recoveries of the assay for water, human serum and urine samples spiked with Hg{sup 2+} were in range of 88.3–107.3% with the relative standard deviations (RSD) of 1.5–9.5% (n = 3). The proposed ICT was used for the detection of Hg{sup 2+} in urine samples collected from Occupational Disease Hospital and the results were confirmed by cold-vapor atomic fluorescence spectroscopy (CV-AFS). The assay exhibited high sensitivity, selectivity, stability, precision and accuracy, demonstrating a promising method for the detection of trace amount of Hg{sup 2+} in environmental water samples and biological serum and urine samples. - Highlights: • The proposed ICT was able to directly detect Hg{sup 2+} without formation of Hg{sup 2+}-ligand complex. • The proposed ICT exhibited high sensitivity, specificity, stability, precision and accuracy for Hg{sup 2+} detection. • The proposed ICT was applicable for the detection of trace amount of Hg{sup 2+} in water, human serum and urine samples.

  10. A competitive immunoassay for ultrasensitive detection of Hg2+ in water, human serum and urine samples using immunochromatographic test based on surface-enhanced Raman scattering

    International Nuclear Information System (INIS)

    She, Pei; Chu, Yanxin; Liu, Chunwei; Guo, Xun; Zhao, Kang; Li, Jianguo; Du, Haijing; Zhang, Xiang; Wang, Hong; Deng, Anping

    2016-01-01

    An immunochromatographic test (ICT) strip was developed for ultrasensitive competitive immunoassay of Hg 2+ . This strategy was achieved by combining the easy-operation and rapidity of ICT with the high sensitivity of surface-enhanced Raman scattering (SERS). Monoclonal antibody (mAb) against Hg 2+ and Raman active substance 4-mercaptobenzoic acid (MBA) dual labelled gold nanoparticles (GNPs) were prepared as an immunoprobe. The Raman scattering intensity of MBA on the test line of the ICT strip was measured for quantitative determination of Hg 2+ . The ICT was able to directly detect Hg 2+ without complexing due to the specific recognition of the mAb with Hg 2+ . The IC 50 and limit of detection (LOD) of the assay for Hg 2+ detection were 0.12 ng mL −1 and 0.45 pg mL −1 , respectively. There was no cross-reactivity (CR) of the assay with other nineteen ions and the ICT strips could be kept for 5 weeks without loss of activity. The recoveries of the assay for water, human serum and urine samples spiked with Hg 2+ were in range of 88.3–107.3% with the relative standard deviations (RSD) of 1.5–9.5% (n = 3). The proposed ICT was used for the detection of Hg 2+ in urine samples collected from Occupational Disease Hospital and the results were confirmed by cold-vapor atomic fluorescence spectroscopy (CV-AFS). The assay exhibited high sensitivity, selectivity, stability, precision and accuracy, demonstrating a promising method for the detection of trace amount of Hg 2+ in environmental water samples and biological serum and urine samples. - Highlights: • The proposed ICT was able to directly detect Hg 2+ without formation of Hg 2+ -ligand complex. • The proposed ICT exhibited high sensitivity, specificity, stability, precision and accuracy for Hg 2+ detection. • The proposed ICT was applicable for the detection of trace amount of Hg 2+ in water, human serum and urine samples.

  11. Matrix removal in state of the art sample preparation methods for serum by charged aerosol detection and metabolomics-based LC-MS.

    Science.gov (United States)

    Schimek, Denise; Francesconi, Kevin A; Mautner, Anton; Libiseller, Gunnar; Raml, Reingard; Magnes, Christoph

    2016-04-07

    Investigations into sample preparation procedures usually focus on analyte recovery with no information provided about the fate of other components of the sample (matrix). For many analyses, however, and particularly those using liquid chromatography-mass spectrometry (LC-MS), quantitative measurements are greatly influenced by sample matrix. Using the example of the drug amitriptyline and three of its metabolites in serum, we performed a comprehensive investigation of nine commonly used sample clean-up procedures in terms of their suitability for preparing serum samples. We were monitoring the undesired matrix compounds using a combination of charged aerosol detection (CAD), LC-CAD, and a metabolomics-based LC-MS/MS approach. In this way, we compared analyte recovery of protein precipitation-, liquid-liquid-, solid-phase- and hybrid solid-phase extraction methods. Although all methods provided acceptable recoveries, the highest recovery was obtained by protein precipitation with acetonitrile/formic acid (amitriptyline 113%, nortriptyline 92%, 10-hydroxyamitriptyline 89%, and amitriptyline N-oxide 96%). The quantification of matrix removal by LC-CAD showed that the solid phase extraction method (SPE) provided the lowest remaining matrix load (48-123 μg mL(-1)), which is a 10-40 fold better matrix clean-up than the precipitation- or hybrid solid phase extraction methods. The metabolomics profiles of eleven compound classes, comprising 70 matrix compounds showed the trends of compound class removal for each sample preparation strategy. The collective data set of analyte recovery, matrix removal and matrix compound profile was used to assess the effectiveness of each sample preparation method. The best performance in matrix clean-up and practical handling of small sample volumes was showed by the SPE techniques, particularly HLB SPE. CAD proved to be an effective tool for revealing the considerable differences between the sample preparation methods. This detector can

  12. A competitive immunoassay for ultrasensitive detection of Hg(2+) in water, human serum and urine samples using immunochromatographic test based on surface-enhanced Raman scattering.

    Science.gov (United States)

    She, Pei; Chu, Yanxin; Liu, Chunwei; Guo, Xun; Zhao, Kang; Li, Jianguo; Du, Haijing; Zhang, Xiang; Wang, Hong; Deng, Anping

    2016-02-04

    An immunochromatographic test (ICT) strip was developed for ultrasensitive competitive immunoassay of Hg(2+). This strategy was achieved by combining the easy-operation and rapidity of ICT with the high sensitivity of surface-enhanced Raman scattering (SERS). Monoclonal antibody (mAb) against Hg(2+) and Raman active substance 4-mercaptobenzoic acid (MBA) dual labelled gold nanoparticles (GNPs) were prepared as an immunoprobe. The Raman scattering intensity of MBA on the test line of the ICT strip was measured for quantitative determination of Hg(2+). The ICT was able to directly detect Hg(2+) without complexing due to the specific recognition of the mAb with Hg(2+). The IC50 and limit of detection (LOD) of the assay for Hg(2+) detection were 0.12 ng mL(-1) and 0.45 pg mL(-1), respectively. There was no cross-reactivity (CR) of the assay with other nineteen ions and the ICT strips could be kept for 5 weeks without loss of activity. The recoveries of the assay for water, human serum and urine samples spiked with Hg(2+) were in range of 88.3-107.3% with the relative standard deviations (RSD) of 1.5-9.5% (n = 3). The proposed ICT was used for the detection of Hg(2+) in urine samples collected from Occupational Disease Hospital and the results were confirmed by cold-vapor atomic fluorescence spectroscopy (CV-AFS). The assay exhibited high sensitivity, selectivity, stability, precision and accuracy, demonstrating a promising method for the detection of trace amount of Hg(2+) in environmental water samples and biological serum and urine samples. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. Evaluation of a commercial Erns-capture ELISA for detection of BVDV in routine diagnostic cattle serum samples

    Directory of Open Access Journals (Sweden)

    Ståhl Karl

    2007-03-01

    Full Text Available Abstract Background Bovine viral diarrhoea virus (BVDV is an important pathogen in cattle. The ability of the virus to cross the placenta during early pregnancy can result in the birth of persistently infected (PI calves. These calves shed the virus during their entire lifespan and are the key transmitters of infection. Consequently, identification (and subsequent removal of PI animals is necessary to rapidly clear infected herds from the virus. The objective of this study was to evaluate the suitability of a commercial Erns-capture ELISA, in comparison to the indirect immunoperoxidase test (IPX, for routine diagnostic detection of BVDV within a control programme. In addition, the effect of passive immunity and heat-inactivation of the samples on the performance of the ELISA was studied. Methods In the process of virus clearance within the Swedish BVDV control programme, all calves born in infected herds are tested for virus and antibodies. From such samples, sent in for routine diagnostics to SVA, we selected 220 sera collected from 32 beef herds and 29 dairy herds. All sera were tested for BVDV antigen using the Erns ELISA, and the results were compared to the results from the IPX used within the routine diagnostics. Results All 130 samples categorized as virus negative by IPX were tested negative in the ELISA, and all 90 samples categorized as virus positive were tested positive, i.e. the relative sensitivity and specificity of the ELISA was 100% in relation to IPX, and the agreement between the tests was perfect. Conclusion We can conclude that the Erns ELISA is a valid alternative that has several advantages compared to IPX. Our results clearly demonstrate that it performs well under Swedish conditions, and that its performance is comparable with the IPX test. It is highly sensitive and specific, can be used for testing of heat-inactivated samples, precolostral testing, and probably to detect PI animals at an earlier age than the IPX.

  14. Quantitative single serum-dilution liquid phase competitive blocking ELISA for the assessment of herd immunity and expected protection against foot-and-mouth disease virus in vaccinated cattle.

    Science.gov (United States)

    Robiolo, Blanca; La Torre, José; Duffy, Sergio; Leon, Emilio; Seki, Cristina; Torres, Adriana; Mattion, Nora

    2010-06-01

    A single serum-dilution liquid phase ELISA (slpELISA) was standardized to be used for serological evaluation of herd immunity against foot-and-mouth disease. The absorbance value at a dilution 1:64 of each serum sample was interpolated in a standard curve by plotting the antibody titers of six control sera determined by end point dilution liquid phase ELISA (lpELISA), against the absorbance values for the same control sera at 1:64 dilutions. A straight line was obtained by linear regression analysis (r>0.90) in the titer range of 1.40-2.40. The reliability of the antibody titers was confirmed by the simultaneous titration of 60 cattle sera by slpELISA and lpELISA, which showed an acceptable correlation (R(2)>0.87) for viral strains A24/Cruzeiro, A/Argentina/01, O1/Campos and C3/Indaial. Titers obtained by both methods were not significantly different (p>0.05), thus confirming that slpELISA could be used successfully to replace the conventional serial dilution ELISA for the assessment of protection status of cattle in epidemiological studies. In addition, this quantitative slpELISA provides an adequate method for monitoring the effectiveness of vaccination campaigns and is also suitable for the assessment of seroconversion of naive animals during early stages of infection. Copyright 2010 Elsevier B.V. All rights reserved.

  15. Collection and Characterization of Samples for Establishment of a Serum Repository for Lyme Disease Diagnostic Test Development and Evaluation

    Science.gov (United States)

    Molins, Claudia R.; Sexton, Christopher; Young, John W.; Ashton, Laura V.; Pappert, Ryan; Beard, Charles B.

    2014-01-01

    Serological assays and a two-tiered test algorithm are recommended for laboratory confirmation of Lyme disease. In the United States, the sensitivity of two-tiered testing using commercially available serology-based assays is dependent on the stage of infection and ranges from 30% in the early localized disease stage to near 100% in late-stage disease. Other variables, including subjectivity in reading Western blots, compliance with two-tiered recommendations, use of different first- and second-tier test combinations, and use of different test samples, all contribute to variation in two-tiered test performance. The availability and use of sample sets from well-characterized Lyme disease patients and controls are needed to better assess the performance of existing tests and for development of improved assays. To address this need, the Centers for Disease Control and Prevention and the National Institutes of Health prospectively collected sera from patients at all stages of Lyme disease, as well as healthy donors and patients with look-alike diseases. Patients and healthy controls were recruited using strict inclusion and exclusion criteria. Samples from all included patients were retrospectively characterized by two-tiered testing. The results from two-tiered testing corroborated the need for novel and improved diagnostics, particularly for laboratory diagnosis of earlier stages of infection. Furthermore, the two-tiered results provide a baseline with samples from well-characterized patients that can be used in comparing the sensitivity and specificity of novel diagnostics. Panels of sera and accompanying clinical and laboratory testing results are now available to Lyme disease serological test users and researchers developing novel tests. PMID:25122862

  16. Field testing of collection cards for Cannabis sativa samples with a single hexanucleotide DNA marker.

    Science.gov (United States)

    Allgeier, Lindsay; Hemenway, John; Shirley, Nicholas; LaNier, Tommy; Coyle, Heather Miller

    2011-09-01

    The validity and feasibility of using DNA collection cards in the field for preservation and analysis of Cannabis sativa genotypes were investigated using a highly specific hexanucleotide marker. Collection cards were submitted to the National Marijuana Initiative, which selectively trained and managed the collection of specific types of samples from a variety of participating agencies. Samples collected at seizure sites included fresh marijuana leaf samples, dried "dispensary" samples, U.S. border seizures, and hashish. Using a standardized PCR kit with custom-labeled oligonucleotide primers specific to marijuana, collection cards produced eight genotypes and 13 different alleles, extremely low baselines, and no cross-reactivity with control plant species. Results were produced from all sample types with the exception of hashish. Plant DNA collection cards represent an easily implementable method for the genetic identification and relatedness of C. sativa street and grow site-seized samples with applications for databasing and market disruption. © 2011 American Academy of Forensic Sciences.

  17. Inert gases in a terra sample - Measurements in six grain-size fractions and two single particles from Lunar 20.

    Science.gov (United States)

    Heymann, D.; Lakatos, S.; Walton, J. R.

    1973-01-01

    Review of the results of inert gas measurements performed on six grain-size fractions and two single particles from four samples of Luna 20 material. Presented and discussed data include the inert gas contents, element and isotope systematics, radiation ages, and Ar-36/Ar-40 systematics.

  18. Isotope Concentrations from 24-h Urine and 3-h Serum Samples Can Be Used to Measure Intestinal Magnesium Absorption in Postmenopausal Women123

    Science.gov (United States)

    Hansen, Karen E.; Nabak, Andrea C.; Johnson, Rachael Erin; Marvdashti, Sheeva; Keuler, Nicholas S.; Shafer, Martin M.; Abrams, Steven A.

    2014-01-01

    Studies suggest a link between magnesium status and osteoporosis. One barrier to more conclusive research on the potential relation is measuring intestinal magnesium absorption (MgA), which requires the use of stable isotopes and a ≥6-d stool or 3-d urine collection. We evaluated alternative methods of measuring MgA. We administered 2 stable magnesium isotopes to 15 postmenopausal women (cohort 1) aged 62 ± 8 y with a dietary magnesium intake of 345 ± 72 mg/d. Participants fasted from 1200 h to 0700 h and then consumed breakfast with ∼23 mg of oral 26Mg and ∼11 mg of i.v. 25Mg. We measured magnesium isotope concentrations in 72-h urine, spot urine (36, 48, 60, and 72 h), and spot serum (1, 3, and 5 h) samples collected after isotope dosing. We calculated MgA using the dose-corrected fraction of isotope concentrations from the 72-h urine collection. We validated new methods in 10 postmenopausal women (cohort 2) aged 59 ± 5 y with a dietary magnesium intake of 325 ± 122 mg/d. In cohort 1, MgA based on the 72-h urine collection was 0.28 ± 0.08. The 72-h MgA correlated most highly with 0–24 h urine MgA value alone (ρ = 0.95, P urine and the 3-h (ρ = 0.93, P urine and 3-h serum MgA values. We conclude that means of 0–24 h urine and 3-h serum MgA provide a reasonable estimate of 72-h MgA. However, if researchers seek to identify small changes in MgA, we recommend a 3-d urine or extended stool collection. This trial was registered at clinicaltrials.gov as NCT01593501. PMID:24500940

  19. Isotope concentrations from 24-h urine and 3-h serum samples can be used to measure intestinal magnesium absorption in postmenopausal women.

    Science.gov (United States)

    Hansen, Karen E; Nabak, Andrea C; Johnson, Rachael Erin; Marvdashti, Sheeva; Keuler, Nicholas S; Shafer, Martin M; Abrams, Steven A

    2014-04-01

    Studies suggest a link between magnesium status and osteoporosis. One barrier to more conclusive research on the potential relation is measuring intestinal magnesium absorption (MgA), which requires the use of stable isotopes and a ≥6-d stool or 3-d urine collection. We evaluated alternative methods of measuring MgA. We administered 2 stable magnesium isotopes to 15 postmenopausal women (cohort 1) aged 62 ± 8 y with a dietary magnesium intake of 345 ± 72 mg/d. Participants fasted from 1200 h to 0700 h and then consumed breakfast with ∼23 mg of oral ²⁶Mg and ∼11 mg of i.v. ²⁵Mg. We measured magnesium isotope concentrations in 72-h urine, spot urine (36, 48, 60, and 72 h), and spot serum (1, 3, and 5 h) samples collected after isotope dosing. We calculated MgA using the dose-corrected fraction of isotope concentrations from the 72-h urine collection. We validated new methods in 10 postmenopausal women (cohort 2) aged 59 ± 5 y with a dietary magnesium intake of 325 ± 122 mg/d. In cohort 1, MgA based on the 72-h urine collection was 0.28 ± 0.08. The 72-h MgA correlated most highly with 0-24 h urine MgA value alone (ρ = 0.95, P urine and the 3-h (ρ = 0.93, P urine and 3-h serum MgA values. We conclude that means of 0-24 h urine and 3-h serum MgA provide a reasonable estimate of 72-h MgA. However, if researchers seek to identify small changes in MgA, we recommend a 3-d urine or extended stool collection.

  20. Excited state interaction between Hydrochlorothiazide and europium ion in PMMA polymer and its application as optical sensor for Hydrochlorothiazide in tablet and serum samples

    Energy Technology Data Exchange (ETDEWEB)

    Attia, M.S., E-mail: Mohamed_sam@yahoo.com [Department of Chemistry, Faculty of Science, Ain Shams University, Abbassia, Cairo (Egypt); Othman, A.M. [Environmental Biotechnology, Genetic Engineering and Biotechnology Institute, Menofiea University (Egypt); Youssef, A.O. [Department of Chemistry, Faculty of Science, Ain Shams University, Abbassia, Cairo (Egypt); El-Raghi, E. [Environmental Biotechnology, Genetic Engineering and Biotechnology Institute, Menofiea University (Egypt)

    2012-08-15

    This paper reports on a facile technique combined with a simple, sensitive and selective spectrofluorimetric method for the determination of hydrochlorothiazide. In methanol, at pH 8.3 and {lambda}{sub ex}=340, hydrochlorothiazide can remarkably enhance the luminescence intensity of the Eu{sup 3+} ion doped in polymethylmethacrylate polymer (PMMA) matrix. This could be due to the energy transfer from hydrochlorothiazide to Eu{sup 3+} in the excited stated. At the optimized experimental conditions, the enhancement of the characteristic emission band (617 nm) of Eu{sup 3+} ion doped PMMA is directly proportional to the concentration of hydrochlorothiazide with a dynamic range of 5 Multiplication-Sign 10{sup -8}-1.0 Multiplication-Sign 10{sup -5} mol L{sup -1} and detection limit of 8.0 Multiplication-Sign 10{sup -9} mol L{sup -1}. Application of the suggested method was successfully applied to the determination of hydrochlorothiazide in pharmaceutical preparations and human serum samples, with high percentage of recovery, good accuracy and precision. - Highlights: Black-Right-Pointing-Pointer HCT was determined by europium sensitized by HCT in PMMA polymer. Black-Right-Pointing-Pointer Band at 617 nm of Eu{sup 3+} ion ({sup 5}D{sub 0}{yields}{sup 7}F{sub 2}) is sensitive to HCT concentration. Black-Right-Pointing-Pointer Recovery and R.S.D for tablets serum samples in proposed method were calculated. Black-Right-Pointing-Pointer Method is verified for HCT determination in real samples with no interferences.

  1. Predictive value of initial serum human chorionic gonadotropin levels for pregnancies after single fresh and frozen blastocyst transfer.

    Science.gov (United States)

    Zhao, Wei-E; Li, Yu-Jie; Ou, Jian-Ping; Sun, Peng; Chen, Wen-Qiu; Liang, Xiao-Yan

    2017-06-01

    As one of the earliest markers for predicting pregnancy outcomes, human chorionic gonadotropin (hCG) values have been inconclusive on reliability of the prediction after frozen and fresh embryo transfer (ET). In this retrospective study, patients with positive hCG (day 12 after transfer) were included to examine the hCG levels and their predictive value for pregnancy outcomes following 214 fresh and 1513 vitrified-warmed single-blastocyst transfer cycles. For patients who got clinical pregnancy, the mean initial hCG value was significantly higher after frozen cycles than fresh cycles, and the similar result was demonstrated for patients with live births (LB). The difference in hCG value existed even after adjusting for the potential covariates. The area under curves (AUC) and threshold values calculated by receiver operator characteristic curves were 0.944 and 213.05 mIU/mL for clinical pregnancy after fresh ET, 0.894 and 399.50 mIU/mL for clinical pregnancy after frozen ET, 0.812 and 222.86 mIU/mL for LB after fresh ET, and 0.808 and 410.80 mIU/mL for LB after frozen ET with acceptable sensitivity and specificity, respectively. In conclusion, single frozen blastocyst transfer leads to higher initial hCG values than single fresh blastocyst transfer, and the initial hCG level is a reliable predictive factor for predicting IVF outcomes.

  2. Label-free isolation and deposition of single bacterial cells from heterogeneous samples for clonal culturing

    OpenAIRE

    J. Riba; T. Gleichmann; S. Zimmermann; R. Zengerle; P. Koltay

    2016-01-01

    The isolation and analysis of single prokaryotic cells down to 1??m and less in size poses a special challenge and requires micro-engineered devices to handle volumes in the picoliter to nanoliter range. Here, an advanced Single-Cell Printer (SCP) was applied for automated and label-free isolation and deposition of bacterial cells encapsulated in 35?pl droplets by inkjet-like printing. To achieve this, dispenser chips to generate micro droplets have been fabricated with nozzles 20??m in size....

  3. Bovine serum albumin-Cu(II) hybrid nanoflowers: An effective adsorbent for solid phase extraction and slurry sampling flame atomic absorption spectrometric analysis of cadmium and lead in water, hair, food and cigarette samples

    Energy Technology Data Exchange (ETDEWEB)

    Yilmaz, Erkan [Department of Chemistry, Faculty of Sciences, Erciyes University, Kayseri 38039 (Turkey); Ocsoy, Ismail [Department of Analytical Chemistry, Faculty of Pharmacy, Erciyes University, Kayseri 38039 (Turkey); Nanotechnology Research Center (ERNAM), Erciyes University, Kayseri 38039 (Turkey); Ozdemir, Nalan [Department of Chemistry, Faculty of Sciences, Erciyes University, Kayseri 38039 (Turkey); Soylak, Mustafa, E-mail: soylak@erciyes.edu.tr [Department of Chemistry, Faculty of Sciences, Erciyes University, Kayseri 38039 (Turkey)

    2016-02-04

    Herein, the synthesis of bovine serum albumin-Cu(II) hybrid nanoflowers (BSA-NFs) through the building blocks of bovine serum albumin (BSA) and copper(II) ions in phosphate buffered saline (PBS) and their use as adsorbent for cadmium and lead ions are reported. The BSA-NFs, for the first time, were efficiently utilized as novel adsorbent for solid phase extraction (SPE) of cadmium and lead ions in water, food, cigarette and hair samples. The method is based on the separation and pre-concentration of Cd(II) and Pb(II) by BSA-NFs prior to determination by slurry analysis via flame atomic absorption spectrometry (FAAS). The analytes were adsorbed on BSA-NFs under the vortex mixing and then the ion-loaded slurry was separated and directly introduced into the flame AAS nebulizer by using a hand-made micro sample introduction system to eliminate a number of drawbacks. The effects of analytical key parameters, such as pH, amount of BSA-NFs, vortexing time, sample volume, and matrix effect of foreign ions on adsorbing of Cd(II) and Pb(II) were systematically investigated and optimized. The limits of detection (LODs) for Cd(II) and Pb(II) were calculated as 0.37 μg L{sup −1} and 8.8 μg L{sup −1}, respectively. The relative standard deviation percentages (RSDs) (N = 5) for Cd(II) and Pb(II) were 7.2%, and 5.0%, respectively. The accuracy of the developed procedure was validated by the analysis of certified reference materials (TMDA-53.3 Fortified Water, TMDA-70 Fortified Water, SPS-WW2 Waste Water, NCSDC-73349 Bush Branches and Leaves) and by addition/recovery analysis. The quantitative recoveries were obtained for the analysis of certified reference materials and addition/recovery tests. The method was successfully applied to the analysis of cadmium and lead in water, food, cigarette and hair samples. - Highlights: • The synthesis of bovine serum albumin-Cu(II) hybrid nanoflowers is reported. • The nanoflowers were utilized for solid phase microextraction of

  4. Detection of rubella-specific serum IgG and IgA and nasopharyngeal IgA responses using a radioactive single radial immunodiffusion technique

    International Nuclear Information System (INIS)

    Al-Nakib, W.; Best, J.M.; Banatvala, J.E.

    1975-01-01

    A radioactive, single radial immunodiffusion technique (RSRID) employing 125 I-labelled antiglobulins, was developed to determine rubella-specific serum IgG and IgA and nasopharyngeal IgA antibody responses following both naturally acquired rubella and vaccination with four attenuated vaccines. Rubella-specific IgG antibodies developed in parallel with haemagglutination inhibiting (HAI) antibodies and both persisted for at least a year in all cases of naturally acquired and vaccine induced infection. However, the RSRID test detected rises in titre in all of five volunteers challenged intranasally with RA27/3, whereas only one volunteer showed a rise by HAI. Serum IgA antibodies generally persisted for at least a year following naturally acquired infection but rubella vaccines induced variable responses. Thus, following administration of RA27/3 and To-336 vaccines, rubella-specific IgA usually persisted for a year, whereas Cendehill vaccine failed to induce a detectable response. Rubella-specific nasopharyngeal IgA was detected in all five patients following naturally acquired infection and was still present in the only two patients tested a year after infection. These antibodies were detected in fourteen of twenty-three vaccinees at 3 weeks, but persisted for a year in only two vaccinees, both of whom were given RA27/3 intranasally. (author)

  5. Concentrations of moxifloxacin in serum and pulmonary compartments following a single 400 mg oral dose in patients undergoing fibre-optic bronchoscopy.

    Science.gov (United States)

    Soman, A; Honeybourne, D; Andrews, J; Jevons, G; Wise, R

    1999-12-01

    The concentrations of moxifloxacin achieved after a single 400 mg dose were measured in serum, epithelial lining fluid (ELF), alveolar macrophages (AM) and bronchial mucosa (BM). Concentrations were determined using a microbiological assay. Nineteen patients undergoing fibre-optic bronchoscopy were studied. Mean serum, ELF, AM and BM concentrations at 2.2, 12 and 24 h were as follows: 2.2 h: 3.2 mg/L, 20.7 mg/L, 56.7 mg/L, 5.4 mg/kg; 12 h: 1.1 mg/L, 5.9 mg/L, 54.1 mg/L, 2.0 mg/kg; 24 h: 0.5 mg/L, 3.6 mg/L, 35.9 mg/L, 1.1 mg/kg, respectively. These concentrations exceed the MIC(90)s for common respiratory pathogens such as Streptococcus pneumoniae (0.25 mg/L), Haemophilus influenzae (0.03 mg/L), Moraxella catarrhalis (0.12 mg/L), Chlamydia pneumoniae (0.12 mg/L) and Mycoplasma pneumoniae (0. 12 mg/L) and indicate that moxifloxacin should be effective in the treatment of community-acquired, lower respiratory tract infections.

  6. Proteomic patterns for classification of ovarian cancer and CTCL serum samples utilizing peak pairs indicative of post-translational modifications.

    Science.gov (United States)

    Liu, Chenwei; Shea, Nancy; Rucker, Sally; Harvey, Linda; Russo, Paul; Saul, Richard; Lopez, Mary F; Mikulskis, Alvydas; Kuzdzal, Scott; Golenko, Eva; Fishman, David; Vonderheid, Eric; Booher, Susan; Cowen, Edward W; Hwang, Sam T; Whiteley, Gordon R

    2007-11-01

    Proteomic patterns as a potential diagnostic technology has been well established for several cancer conditions and other diseases. The use of machine learning techniques such as decision trees, neural networks, genetic algorithms, and other methods has been the basis for pattern determination. Cancer is known to involve signaling pathways that are regulated through PTM of proteins. These modifications are also detectable with high confidence using high-resolution MS. We generated data using a prOTOF mass spectrometer on two sets of patient samples: ovarian cancer and cutaneous t-cell lymphoma (CTCL) with matched normal samples for each disease. Using the knowledge of mass shifts caused by common modifications, we built models using peak pairs and compared this to a conventional technique using individual peaks. The results for each disease showed that a small number of peak pairs gave classification equal to or better than the conventional technique that used multiple individual peaks. This simple peak picking technique could be used to guide identification of important peak pairs involved in the disease process.

  7. A longitudinal study of alterations of hippocampal volumes and serum BDNF levels in association to atypical antipsychotics in a sample of first-episode patients with schizophrenia.

    Directory of Open Access Journals (Sweden)

    Emmanouil Rizos

    Full Text Available BACKGROUND: Schizophrenia is associated with structural and functional abnormalities of the hippocampus, which have been suggested to play an important role in the formation and emergence of schizophrenia syndrome. Patients with schizophrenia exhibit significant bilateral hippocampal volume reduction and progressive hippocampal volume decrease in first-episode patients with schizophrenia has been shown in many neuroimaging studies. Dysfunction of the neurotrophic system has been implicated in the pathophysiology of schizophrenia. The initiation of antipsychotic medication alters the levels of serum Brain Derived Neurotrophic Factor (BDNF levels. However it is unclear whether treatment with antipsychotics is associated with alterations of hippocampal volume and BDNF levels. METHODS: In the present longitudinal study we investigated the association between serum BDNF levels and hippocampal volumes in a sample of fourteen first-episode drug-naïve patients with schizophrenia (FEP. MRI scans, BDNF and clinical measurements were performed twice: at baseline before the initiation of antipsychotic treatment and 8 months later, while the patients were receiving monotherapy with second generation antipsychotics (SGAs. RESULTS: We found that left hippocampal volume was decreased (corrected left HV [t = 2.977, df = 13, p = .011] at follow-up; We also found that the higher the BDNF levels change the higher were the differences of corrected left hippocampus after 8 months of treatment with atypical antipsychotics (Pearson r = 0.597, p = 0.024. CONCLUSIONS: The association of BDNF with hippocampal volume alterations in schizophrenia merits further investigation and replication in larger longitudinal studies.

  8. Evaluation of a generic immunoassay with drug tolerance to detect immune complexes in serum samples from cynomolgus monkeys after administration of human antibodies.

    Science.gov (United States)

    Stubenrauch, Kay; Wessels, Uwe; Essig, Ulrich; Vogel, Rudolf; Schleypen, Julia

    2010-06-05

    Current state of the art bridging ELISA technologies for detection of anti-drug antibodies (ADAs) against therapeutic antibodies bear the risk of false-negative results due to interference by circulating drug. Methods to remove the drug in the sample or sample pre-treatment techniques such as acid dissociation of the immune complexes are limited, laborious and may destroy ADAs resulting again in false-negative results. The immune complex ELISA described in this publication provides a simple solution. It is designed to analyze samples from cynomolgus monkeys dosed with human antibodies; it can be used for all human antibodies since it is independent of the specific antibody and its target. The generic applicability of the ADA assay is enabled by the use of (1) a murine anti-human Fc monoclonal antibody (MAb) as capture reagent; (2) a murine anti-cynomolgus monkey IgG MAb as detection reagent; and (3) an ADA positive control conjugate consisting of cynomolgus IgG complexed with human IgG. In its basic version, the generic ADA ELISA specifically detects only immune complexes formed in vivo. Validation of the ADA assay revealed a lower limit of quantitation of 15.6 ng/mL in serum samples. Intra-assay and inter-assay precision was characterized by a coefficient of variation of less than 10% and accuracy was within 8%. Matrix effects were low as evidenced by a mean recovery of 95%. In vitro pre-incubation of the serum samples with drug makes also the free ADA in the sample amenable to measurement by the immune complex ELISA as demonstrated by analysis of ADAs from two cynomolgus monkey studies with two different antibodies. The generic and versatile nature of this ADA assay favors its use in pilot pharmacokinetic and safety studies in cynomolgus monkeys during candidate selection of antibodies. The assay can help to explain unexpected drug clearance profiles, loss of efficacy or safety events caused by immune complexes and guide further development. Copyright (c) 2010

  9. Single daily dosing of antibiotics: importance of in vitro killing rate, serum half-life, and protein binding.

    Science.gov (United States)

    Potel, G; Chau, N P; Pangon, B; Fantin, B; Vallois, J M; Faurisson, F; Carbon, C

    1991-10-01

    The relative importance of pharmacokinetic and pharmacodynamic parameters for the feasibility of a single daily dose (SDD) of antibiotics remains to be established. Therefore, we studied the relationship between in vitro bacteriological parameters (MIC, MBC, and killing rate [KR], defined as the reduction in the inoculum within 3 h), pharmacokinetic parameters (t1/2 and protein binding [PB], and in vivo antibacterial effect of a single antibiotic dose in an experimental rabbit model of Escherichia coli endocarditis. Nine antibiotics were investigated: two aminoglycosides, two quinolones, and five beta-lactams. For each drug, the minimal effective dose (MED) (in milligrams per kilogram) was defined as the lowest dose able to achieve a significant difference (P less than 0.05) of CFU in the vegetations in comparison with controls 24 h after a single intravenous injection. Aminoglycosides and quinolones had the lowest MEDs, followed by beta-lactams. Univariate regression analysis showed that KR was the major determinant of MED. A stepwise regression analysis showed that t1/2 significantly improved the predictive value of KR, while PB, MIC, and MBC did not. The final equation was MED = 1,586-238 KR-297 t1/2 (r = 0.90, P = 0.01). We concluded that the pharmacodynamic parameters (especially the high KR) of aminoglycosides and quinolones explained their low MEDs and might allow SDD. In contrast, the low KR of beta-lactams emphasized the critical importance of a long t1/2, as for ceftriaxone, allowing the use of this beta-lactam alone in SDD.

  10. Use of the granulosa cell aromatase bioassay for measurement of bioactive follicle-stimulating hormone in urine and serum samples of diverse species.

    Science.gov (United States)

    Dahl, K D; Hsueh, A J

    1987-01-01

    Ovarian steroids and growth factors are intragonadal modulators which augment a key endpoint of follicle-stimulating hormone (FSH) action in granulosa cells: the induction of aromatase activity. Studies of these paracrine hormones that enhance FSH-stimulated estrogen biosynthesis by cultured rat granulosa cells, have led to the development of a sensitive and specific in vitro bioassay for FSH. This newly developed granulosa cell aromatase bioassay (GAB) allows for the measurement of bioactive FSH levels in serum and urine of humans and animals with various physiological and pathological conditions. These studies have demonstrated that the GAB assay is useful in detecting possible changes in the molecular forms of FSH. The adaptation of this method for urine samples allows for the measurement of bio-FSH levels in situations where venipuncture is not practical or in species for which specific radioimmunoassays are not available.

  11. Single point aerosol sampling: Evaluation of mixing and probe performance in a nuclear stack

    Energy Technology Data Exchange (ETDEWEB)

    Rodgers, J.C.; Fairchild, C.I.; Wood, G.O. [Los Alamos National Laboratory, NM (United States)] [and others

    1995-02-01

    Alternative Reference Methodologies (ARMs) have been developed for sampling of radionuclides from stacks and ducts that differ from the methods required by the U.S. EPA. The EPA methods are prescriptive in selection of sampling locations and in design of sampling probes whereas the alternative methods are performance driven. Tests were conducted in a stack at Los Alamos National Laboratory to demonstrate the efficacy of the ARMs. Coefficients of variation of the velocity tracer gas, and aerosol particle profiles were determined at three sampling locations. Results showed numerical criteria placed upon the coefficients of variation by the ARMs were met at sampling stations located 9 and 14 stack diameters from flow entrance, but not at a location that is 1.5 diameters downstream from the inlet. Experiments were conducted to characterize the transmission of 10 {mu}m aerodynamic equivalent diameter liquid aerosol particles through three types of sampling probes. The transmission ratio (ratio of aerosol concentration at the probe exit plane to the concentration in the free stream) was 107% for a 113 L/min (4-cfm) anisokinetic shrouded probe, but only 20% for an isokinetic probe that follows the EPA requirements. A specially designed isokinetic probe showed a transmission ratio of 63%. The shrouded probe performance would conform to the ARM criteria; however, the isokinetic probes would not.

  12. Effects of a Single-Session Cognitive Enhancement Fitness Program on Serum Brain-Derived Neurotrophic Factor Levels and Cognitive Function in Middle-Aged Women

    Directory of Open Access Journals (Sweden)

    Hyun Jun Kim, Sang Yeoup Lee, Hwa Gyeong Lee, Yang Hee Cho, Eun Mi Ko

    2018-03-01

    Full Text Available Few studies have been undertaken to develop cognitive functional improvement-focused exercise programs and determine their effect. The objectives of this study were to evaluate the effects of a cognitive enhancement fitness program (CEFP on short-term memory and serum brain-derived neurotrophic factor (BDNF levels according to the cognitive state in middle-aged women. A total of 30 healthy volunteers aged 40–59 years were divided into two groups, that is, a mild cognitive impairment (MCI group and a non-MCI group based on results from the Korean Dementia Screening Questionnaire. A single-session CEFP was conducted over 50 min and consisted of four parts: warm-up, low intensity interval circulation dance exercises, moderate intensity resistance exercises using elastic bands, and cool-down. Serum BDNF levels were measured by ELISA and short-term memory determined by forward digit/word span test was assessed before and after CEFP. After CEFP, forward digit/word span test scores and BDNF levels increased to median 119.2%/115.1% and 118.7%, respectively. After CEFP, the MCI and non-MCI groups produced higher forward digit span test scores (from 6.7 ± 1.5 to 7.5 ± 1.4 points, p = 0.023 and from 6.2 ± 2.0 to 7.0 ± 2.1 points, P=0.011, respectively. After CEFP, forward word span scores and BDNF levels increased (from 3.5 ± 1.7 to 4.6 ± 1.8 points, p = 0.029 and from 610.8 ± 221.1 to 757.9 ± 267.9 pg/ml, p = 0.017, respectively in non-MCI group only. No group differences were observed between change in short-term memory and change in BDNF. Short-term memory and BDNF levels after CEFP were found to be negatively correlated with age, but pre- to post-intervention changes in short-term memory and BDNF were not. The present study shows that a single, 50-minute CEFP improved short-term memory and increased serum BDNF levels in healthy middle-aged women, especially those without MCI.

  13. A new supramolecular based liquid solid microextraction method for preconcentration and determination of trace bismuth in human blood serum and hair samples by electrothermal atomic absorption spectrometry.

    Science.gov (United States)

    Kahe, Hadi; Chamsaz, Mahmoud

    2016-11-01

    A simple and reliable supramolecule-aggregated liquid solid microextraction method is described for preconcentration and determination of trace amounts of bismuth in water as well as human blood serum and hair samples. Catanionic microstructures of cetyltrimethylammonium bromide (CTAB) and sodium dodecyl sulfate (SDS) surfactants, dissolved in deionized water/propanol, are used as a green solvent to extract bismuth (III)-diethyldithiocarbamate complexes by dispersive microextraction methodology. The extracted solid phase is easily removed and dissolved in 50 μL propanol for subsequent measurement by electrothermal atomic absorption spectrometry (ET-AAS). The procedure benefits the merits of supramolecule aggregates' properties and dispersive microextraction technique using water as the main component of disperser solvent, leading to direct interaction with analyte. Phase separation behavior of extraction solvent and different parameters influencing the extraction efficiency of bismuth ion such as salt concentration, pH, centrifugation time, amount of chelating agent, SDS:CTAB mole ratio, and solvent amounts were thoroughly optimized. Under the optimal experimental conditions, the calibration curve was linear in the range of 0.3-6 μg L -1 Bi (III) with a limit of detection (LOD) of 0.16 μg L -1 (S/N = 3). The relative standard deviations (RSD) of determination were obtained to be 5.1 and 6.2 % for 1 and 3 μg L -1 of Bi (III), respectively. The developed method was successfully applied as a sensitive and accurate technique for determination of bismuth ion in human blood serum, hair samples, and a certified reference material.

  14. β-Cyclodextrin anchoring onto pericarpium granati-derived magnetic mesoporous carbon for selective capture of lopid in human serum and pharmaceutical wastewater samples.

    Science.gov (United States)

    Liu, Rui-Lin; Zhang, Zhi-Qi; Jing, Wang-Hui; Wang, Lu; Luo, Zhi-Min; Chang, Rui-Miao; Zeng, Ai-Guo; Du, Wei; Chang, Chun; Fu, Qiang

    2016-05-01

    Functionalized magnetic carbonaceous nanomaterials, which are important materials with many practical and research applications in biomedical, pharmaceutical and biological fields, have recently attracted much attention. In this study, a magnetic mesoporous carbon coated with β-cyclodextrin (MMC@β-CD) was synthesized for the first time from natural pericarpium granati (PG). The as-obtained MMC@β-CD has high surface areas (203 m(2)g(-1)), large pore volumes (0.16 cm(3)g(-1)), relatively broad mesoporous sizes (6.8 nm) and a high saturation magnetization of 26.2 emu g(-1), which is sufficient for magnetic separation by an external magnetic field. The MMC@β-CD was used as an innovative adsorbent for magnetic solid-phase extraction of lopid via host-guest interaction prior to spectrofluorometric analysis. The proposed method was successfully applied to analyze lopid in human serum and pharmaceutical wastewater samples with recoveries in the range of 85.0-103.5% for the spiked samples. Overall, this work not only provides an inexpensive and eco-friendly method to fabricate MMC@β-CD (or MMC) from PG, but also develops a highly selective approach for capture of lopid in biological samples and environmental substances. Copyright © 2016 Elsevier B.V. All rights reserved.

  15. Automated isotope dilution liquid chromatography-tandem mass spectrometry with on-line dilution and solid phase extraction for the measurement of cortisol in human serum sample.

    Science.gov (United States)

    Kawaguchi, Migaku; Eyama, Sakae; Takatsu, Akiko

    2014-08-05

    A candidate reference measurement procedure involving automated isotope dilution coupled with liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS) with on-line dilution and solid phase extraction (SPE) has been developed and critically evaluated. We constructed the LC-MS/MS with on-line dilution and SPE system. An isotopically labelled internal standard, cortisol-d4, was added to serum sample. After equilibration, the methanol was added to the sample, and deproteination was performed. Then, the sample was applied to the LC-MS/MS system. The limit of detection (LOD) and limit of quantification (LOQ) were 0.2 and 1ngg(-1), respectively. Excellent precision was obtained with within-day variation (RSD) of 1.9% for ID-LC-MS/MS analysis (n=6). This method, which demonstrates simple, easy, good accuracy, high precision, and is free from interferences from structural analogues, qualifies as a reference measurement procedure. Copyright © 2014 Elsevier B.V. All rights reserved.

  16. A single lysis solution for the analysis of tissue samples by different proteomic technologies

    DEFF Research Database (Denmark)

    Gromov, P.; Celis, J.E.; Gromova, I.

    2008-01-01

    -based proteomics (reverse-phase lysate arrays or direct antibody arrays), allowing the direct comparison of qualitative and quantitative data yielded by these technologies when applied to the same samples. The usefulness of the CLB1 solution for gel-based proteomics was further established by 2D PAGE analysis...... taken place in molecular biology, cell biology and genomics there is a pressing need to accelerate the translation of basic discoveries into clinical applications. This need, compounded by mounting evidence that cellular model systems are unable to fully recapitulate all biological aspects of human...... dissease, is driving scientists to increasingly use clinically relevant samples for biomarker and target discovery. Tissues are heterogeneous and as a result optimization of sample preparation is critical for generating accurate, representative, and highly reproducible quantitative data. Although a large...

  17. Measurement of glomerular filtration rate in adults: accuracy of five single-sample plasma clearance methods

    DEFF Research Database (Denmark)

    Rehling, M; Rabøl, A

    1989-01-01

    After an intravenous injection of a tracer that is removed from the body solely by filtration in the kidneys, the glomerular filtration rate (GFR) can be determined from its plasma clearance. The method requires a great number of blood samples but collection of urine is not needed. In the present...

  18. Determination of burial dose in incompletely bleached fluvial samples using single grains of quartz

    DEFF Research Database (Denmark)

    Thomsen, Kristina Jørkov; Murray, A.S.; Bøtter-Jensen, Lars

    2007-01-01

    -bleached and gamma-irradiated samples. We show that there is a linear relationship between the over-dispersion and the mean dose. Knowing this uncertainty relationship enables us to estimate the burial dose by comparing the predicted uncertainty on the running mean with that calculated from actual dispersion. (c...

  19. Quantitative in-situ TEM nanotensile testing of single crystal Ni facilitated by a new sample preparation approach.

    Science.gov (United States)

    Samaeeaghmiyoni, Vahid; Idrissi, Hosni; Groten, Jonas; Schwaiger, Ruth; Schryvers, Dominique

    2017-03-01

    Twin-jet electro-polishing and Focused Ion Beam (FIB) were combined to produce small size Nickel single crystal specimens for quantitative in-situ nanotensile experiments in the transmission electron microscope. The combination of these techniques allows producing samples with nearly defect-free zones in the centre in contrast to conventional FIB-prepared samples. Since TEM investigations can be performed on the electro-polished samples prior to in-situ TEM straining, specimens with desired crystallographic orientation and initial microstructure can be prepared. The present results reveal a dislocation nucleation-controlled plasticity, in which small loops induced by FIB near the edges of the samples play a central role. Copyright © 2016 Elsevier Ltd. All rights reserved.

  20. A proposal for the measurement of Rashba and Dresselhaus spin–orbit interaction strengths in a single sample

    International Nuclear Information System (INIS)

    Maiti, Santanu K.; Sil, Shreekantha; Chakrabarti, Arunava

    2012-01-01

    We establish an exact analytical treatment for the determination of the strengths of the Rashba and Dresselhaus spin–orbit interactions in a single sample by measuring persistent spin current. A hidden symmetry is exploited in the Hamiltonian to show that the spin current vanishes when the strength of the Dresselhaus interaction becomes equal to the strength of the Rashba term. The results are sustained even in the presence of disorder and thus an experiment in this regard will be challenging. -- Highlights: ► An exact analytical treatment is given for the measurement of spin–orbit interaction strengths in a single sample. ► Persistent spin current is calculated. ► Our present analysis gives us confidence to propose an experiment in this line.

  1. Full quantification of selenium species by RP and AF-ICP-qMS with on-line isotope dilution in serum samples from mercury-exposed people supplemented with selenium-enriched yeast

    DEFF Research Database (Denmark)

    Li, Yu-Feng; Hu, Liang; Li, Bai

    2011-01-01

    Accurate determination of selenium (Se) species in biological samples is a critical issue because Se commonly occurs at low levels and in diverse species. The method for the full quantification of Se species in serum samples was proposed through combined ion-pair reverse-phase (RP) chromatography...

  2. Isolation of RNA from tumor samples: single-step guanidinium acid-phenol method.

    Science.gov (United States)

    Robertson, Naomi; Leek, Russell

    2006-01-01

    The guanidinium acid-phenol method of RNA extraction is relatively fast (4 h) and is useful for the processing of large numbers of samples, without the need for ultracentrifugation. This protocol produces total RNA that includes ribosomal, transfer, and messenger RNA. This high-quality RNA is suitable for Northern blot analysis, dot-blot hybridization, poly (A) RNA selection, in vitro translation, cDNA library construction, reverse transcriptase-polymerase chain reaction, ribonuclease protection assay, and primer extension experiments.

  3. Hematologic and serum biochemical reference intervals for free-ranging common bottlenose dolphins (Tursiops truncatus) and variation in the distributions of clinicopathologic values related to geographic sampling site.

    Science.gov (United States)

    Schwacke, Lori H; Hall, Ailsa J; Townsend, Forrest I; Wells, Randall S; Hansen, Larry J; Hohn, Aleta A; Bossart, Gregory D; Fair, Patricia A; Rowles, Teresa K

    2009-08-01

    To develop robust reference intervals for hematologic and serum biochemical variables by use of data derived from free-ranging bottlenose dolphins (Tursiops truncatus) and examine potential variation in distributions of clinicopathologic values related to sampling sites' geographic locations. 255 free-ranging bottlenose dolphins. Data from samples collected during multiple bottlenose dolphin capture-release projects conducted at 4 southeastern US coastal locations in 2000 through 2006 were combined to determine reference intervals for 52 clinicopathologic variables. A nonparametric bootstrap approach was applied to estimate 95th percentiles and associated 90% confidence intervals; the need for partitioning by length and sex classes was determined by testing for differences in estimated thresholds with a bootstrap method. When appropriate, quantile regression was used to determine continuous functions for 95th percentiles dependent on length. The proportion of out-of-range samples for all clinicopathologic measurements was examined for each geographic site, and multivariate ANOVA was applied to further explore variation in leukocyte subgroups. A need for partitioning by length and sex classes was indicated for many clinicopathologic variables. For each geographic site, few significant deviations from expected number of out-of-range samples were detected. Although mean leukocyte counts did not vary among sites, differences in the mean counts for leukocyte subgroups were identified. Although differences in the centrality of distributions for some variables were detected, the 95th percentiles estimated from the pooled data were robust and applicable across geographic sites. The derived reference intervals provide critical information for conducting bottlenose dolphin population health studies.

  4. A retrospective study of 1,098 blood samples with anemia from adult cats: frequency, classification, and association with serum creatinine concentration.

    Science.gov (United States)

    Furman, E; Leidinger, E; Hooijberg, E H; Bauer, N; Beddies, G; Moritz, A

    2014-01-01

    Frequency and classification of anemia in terms of regeneration status and erythrocyte indices are not well described in cats. To determine frequency and regenerative status of anemia in samples from adult cats, to assess the sensitivity and specificity of macrocytosis and hypochromasia for detecting regenerative anemia (RA), and to evaluate the association of anemia with increased serum creatinine concentration (SC). Laboratory records from 30,503 blood samples from cats (2003-2011). Clinicopathologic data reviewed retrospectively. Anemia defined as hematocrit (Ht) ≤27%, red blood cell count (RBC) ≤5.5 × 10(6)/μL and hemoglobin (Hb) ≤9.0 g/dL. RA defined by manual absolute reticulocyte count >50 × 10(3)/μL. Macrocytosis was defined as mean corpuscular volume (MCV) >55 fL and hypochromasia as mean corpuscular hemoglobin concentration (MCHC) anemia, 633 of 1,098 (57.7%) classified as nonregenerative (NRA) and 465 of 1,098 (42.3%) as regenerative. RBC, Ht, and Hb were significantly lower in the RA compared to NRA group (P Anemia was more severe in cats with RA. Erythrocyte indices were not sensitive indicators of RA. Copyright © 2014 by the American College of Veterinary Internal Medicine.

  5. Single blood-Hg samples can result in exposure misclassification: temporal monitoring within the Japanese community (United States

    Directory of Open Access Journals (Sweden)

    Tsuchiya Ami

    2012-06-01

    Full Text Available Abstract Background The most prominent non-occupational source of exposure to methylmercury is the consumption of fish. In this study we examine a fish consuming population to determine the extent of temporal exposure and investigate the extent to which single time estimates of methylmercury exposure based on blood-Hg concentration can provide reliable estimates of longer-term average exposure. Methods Blood-mercury levels were obtained from a portion of the Arsenic Mercury Intake Biometric Study (AMIBS cohort. Specifically, 56 Japanese women residing in the Puget Sound area of Washington State, US were sampled on three occasions across a one-year period. Results An average of 135 days separated samples, with mean blood-mercury levels for the visits being 5.1, 6.6 and 5.0 μg/l and geometric means being 2.7, 4.5 and 3.1 μg/l. The blood-mercury levels in this group exceed national averages with geometric means for two of the visits being between the 90th and 95th percentiles of nationally observed levels and the lowest geometric mean being between the 75th and 90th percentile. Group means were not significantly different across sampling periods suggesting that exposure of combined subjects remained relatively constant. Comparing intra-individual results over time did not reveal a strong correlation among visits (r = 0.19, 0.50, 0.63 between 1st and 2nd, 2nd and 3rd, and 1st and 3rd sample results, respectively. In comparing blood-mercury levels across two sampling interval combinations (1st and 2nd, 2nd and 3rd, and 1st and 3rd visits, respectively, 58% (n = 34, 53% (n = 31 and 29% (n = 17 of the individuals had at least a 100% difference in blood-Hg levels. Conclusions Point estimates of blood-mercury, when compared with three sample averages, may not reflect temporal variability and individual exposures estimated on the basis of single blood samples should be treated with caution as indicators of long-term exposure

  6. A method for multiple sequential analyses of macrophage functions using a small single cell sample

    Directory of Open Access Journals (Sweden)

    F.R.F. Nascimento

    2003-09-01

    Full Text Available Microbial pathogens such as bacillus Calmette-Guérin (BCG induce the activation of macrophages. Activated macrophages can be characterized by the increased production of reactive oxygen and nitrogen metabolites, generated via NADPH oxidase and inducible nitric oxide synthase, respectively, and by the increased expression of major histocompatibility complex class II molecules (MHC II. Multiple microassays have been developed to measure these parameters. Usually each assay requires 2-5 x 10(5 cells per well. In some experimental conditions the number of cells is the limiting factor for the phenotypic characterization of macrophages. Here we describe a method whereby this limitation can be circumvented. Using a single 96-well microassay and a very small number of peritoneal cells obtained from C3H/HePas mice, containing as little as <=2 x 10(5 macrophages per well, we determined sequentially the oxidative burst (H2O2, nitric oxide production and MHC II (IAk expression of BCG-activated macrophages. More specifically, with 100 µl of cell suspension it was possible to quantify H2O2 release and nitric oxide production after 1 and 48 h, respectively, and IAk expression after 48 h of cell culture. In addition, this microassay is easy to perform, highly reproducible and more economical.

  7. Estimation of effective renal plasma flow in children by use of a single plasma sample after injection of orthoiodohippurate

    International Nuclear Information System (INIS)

    Tauxe, W.N.; Hagge, W.; Stickler, G.B.

    1975-01-01

    Estimates of effective renal plasma flow (ERPF) in adults have been greatly simplified by the use of recently developed regression equations based on a single plasma concentration of radioiodinated orthoiodohippurate (OIH) obtained 44 min after a single intravenous injection of the material. The paper reports similar equations for the prediction of ERPF in children. Studies were made in 30 children of both sexes, aged 4 to 16 years, with a wide variety of renal diseases. A single intravenous injection of labelled OIH was made and plasma was sampled at 10, 15, 20, 25, 30, 40, 50 and 60 min after injection. Plasma concentration curves were analysed by the conventional two-compartment analysis technique (Sapirstein, Matthews) and ERPF was computed from them. In addition to ERPF calculations, sizes of the two volumes of distribution (V 1 and V 2 ), intercompartmental flow rates and fractional rate constants were also calculated. Surface area (SA) was calculated from the DuBois height-weight regression formula. Reciprocals of the OIH plasma concentration in terms of per cent injected dose per litre were calculated at each sampling time; this reciprocal is designated x. These values at each sampling time were plotted against ERPF and regression equations and residual error (Sy.x) were calculated. The optimal sampling time was found to occur at 53 min and the corresponding linear regression equation was 19.33 + 3.87x with a Sy.x value of 36 ml. This compares with an optimal sampling time in adults of 44 min. The mean initial volume of distribution (V 1 ) was found to be 5.3 litres and the mean V 2 was found to be 6.8 litres. In contrast to findings in the previous study in adults these volumes were found to correlate well with SA. A mean intercompartmental flow rate of 276 ml/min was found. No correlation between this value and clinical diagnosis was found. The relationship of the concentration reciprocal and plasma flow was a linear one instead of the polynomial one

  8. Comparison of PRRSV Nucleic Acid and Antibody Detection in Pen-Based Oral Fluid and Individual Serum Samples in Three Different Age Categories of Post-Weaning Pigs from Endemically Infected Farms.

    Directory of Open Access Journals (Sweden)

    Nick De Regge

    Full Text Available Porcine reproductive and respiratory syndrome virus (PRRSV is the causative agent of an economically important disease in swine. Since it has been shown that PRRSV and PRRSV specific antibodies can be detected in oral fluid, many different aspects have been studied to show that oral fluid could be a worthy alternative diagnostic sample to serum for monitoring and surveillance of this disease. Thorough field evaluations are however missing to convincingly show its usefulness under representative field conditions.Pen-based oral fluid samples and serum samples from all individual pigs in the corresponding pens were collected from post-weaning pigs of three different age categories in eight endemically PRRSV infected farms and one PRRSV free farm in Belgium. All samples were tested by quantitative reverse transcription polymerase chain reaction (qRT-PCR and ELISA to detect PRRSV RNA and PRRSV specific antibodies, respectively.While the relative specificity of PRRSV detection by qRT-PCR in pen-based oral fluid compared to serum collected from individual pigs was high in all age categories (>90%, the relative sensitivity decreased with the age of the pigs (89, 93 and 10% in 8-12w, 16-20w and 24-28w old pigs, respectively. The latter correlated with a lower percentage of PRRSV positive pigs in serum/pen in the different age categories (55, 29 and 6%, respectively. Irrespective of the age category, pen-based oral fluid samples were always found PCR positive when at least 30% of the individual pigs were positive in serum. PRRSV specific antibody detection in oral fluid by ELISA showed a 100% relative sensitivity to detection in serum since oral fluid samples were always positive as soon as one pig in the pen was positive in serum. On the other hand, two false positive oral fluid samples in 11 pens without serum positive pigs were found, resulting in a relative specificity of 82%. Indications are however present that the oral fluid result indicated the

  9. Comparison of PRRSV Nucleic Acid and Antibody Detection in Pen-Based Oral Fluid and Individual Serum Samples in Three Different Age Categories of Post-Weaning Pigs from Endemically Infected Farms

    Science.gov (United States)

    De Regge, Nick; Cay, Brigitte

    2016-01-01

    Background Porcine reproductive and respiratory syndrome virus (PRRSV) is the causative agent of an economically important disease in swine. Since it has been shown that PRRSV and PRRSV specific antibodies can be detected in oral fluid, many different aspects have been studied to show that oral fluid could be a worthy alternative diagnostic sample to serum for monitoring and surveillance of this disease. Thorough field evaluations are however missing to convincingly show its usefulness under representative field conditions. Methodology Pen-based oral fluid samples and serum samples from all individual pigs in the corresponding pens were collected from post-weaning pigs of three different age categories in eight endemically PRRSV infected farms and one PRRSV free farm in Belgium. All samples were tested by quantitative reverse transcription polymerase chain reaction (qRT-PCR) and ELISA to detect PRRSV RNA and PRRSV specific antibodies, respectively. Results While the relative specificity of PRRSV detection by qRT-PCR in pen-based oral fluid compared to serum collected from individual pigs was high in all age categories (>90%), the relative sensitivity decreased with the age of the pigs (89, 93 and 10% in 8-12w, 16-20w and 24-28w old pigs, respectively). The latter correlated with a lower percentage of PRRSV positive pigs in serum/pen in the different age categories (55, 29 and 6%, respectively). Irrespective of the age category, pen-based oral fluid samples were always found PCR positive when at least 30% of the individual pigs were positive in serum. PRRSV specific antibody detection in oral fluid by ELISA showed a 100% relative sensitivity to detection in serum since oral fluid samples were always positive as soon as one pig in the pen was positive in serum. On the other hand, two false positive oral fluid samples in 11 pens without serum positive pigs were found, resulting in a relative specificity of 82%. Indications are however present that the oral fluid

  10. Testing the accuracy of a Bayesian central-dose model for single-grain OSL, using known-age samples

    DEFF Research Database (Denmark)

    Guerin, Guillaume; Combès, Benoit; Lahaye, Christelle

    2015-01-01

    remains a difficult task, given the typically considerable dispersion in equivalent dose values measured by OSL - and the numerous sources of such dispersion in measurements. Here, we present the study of 19 samples for which independent age control is available, and whose ages range from 2 to 46ka. Based......-grain OSL and reference ages is about twice as large for the standard approach (12%) as with the Bayesian model (7%). Statistical tests show that, based on our (limited) dataset, the difference between the two models seems to be significant for samples in the age range 4-46ka. Finally, the influence...... on multi-grain OSL age estimates, these samples are presumed to have been both well-bleached at burial, and unaffected by mixing after deposition. Two ways of estimating single-grain ages are then compared: the standard approach on the one hand, consisting of applying the Central Age Model to De values...

  11. Proton-induced single event upset characterisation of a 1 giga-sample per second analog to digital converter

    International Nuclear Information System (INIS)

    Reed, R.A.; Marshall, P.W.; Carts, M.A.

    1999-01-01

    The SPT7760 is an analog to digital converter that is used in satellite for digital processing. In this paper we describe the characterization and analysis of proton-induced single event upsets (SEU) for the SPT7760 operating at sample rates from 125 Msps (Mega-samples per second) to 1 Gsps. The SEU cross-section has been measured as a function of sample rate for various input levels. The data collected is clearly non-linear for all cases. The data shows that this device has a relative low cross-section for proton-induced SEUs and remains functional at a proton dose of 580 krad (Si). (A.C.)

  12. Bovine serum albumin-Cu(II) hybrid nanoflowers: An effective adsorbent for solid phase extraction and slurry sampling flame atomic absorption spectrometric analysis of cadmium and lead in water, hair, food and cigarette samples.

    Science.gov (United States)

    Yilmaz, Erkan; Ocsoy, Ismail; Ozdemir, Nalan; Soylak, Mustafa

    2016-02-04

    Herein, the synthesis of bovine serum albumin-Cu(II) hybrid nanoflowers (BSA-NFs) through the building blocks of bovine serum albumin (BSA) and copper(II) ions in phosphate buffered saline (PBS) and their use as adsorbent for cadmium and lead ions are reported. The BSA-NFs, for the first time, were efficiently utilized as novel adsorbent for solid phase extraction (SPE) of cadmium and lead ions in water, food, cigarette and hair samples. The method is based on the separation and pre-concentration of Cd(II) and Pb(II) by BSA-NFs prior to determination by slurry analysis via flame atomic absorption spectrometry (FAAS). The analytes were adsorbed on BSA-NFs under the vortex mixing and then the ion-loaded slurry was separated and directly introduced into the flame AAS nebulizer by using a hand-made micro sample introduction system to eliminate a number of drawbacks. The effects of analytical key parameters, such as pH, amount of BSA-NFs, vortexing time, sample volume, and matrix effect of foreign ions on adsorbing of Cd(II) and Pb(II) were systematically investigated and optimized. The limits of detection (LODs) for Cd(II) and Pb(II) were calculated as 0.37 μg L(-)(1) and 8.8 μg L(-)(1), respectively. The relative standard deviation percentages (RSDs) (N = 5) for Cd(II) and Pb(II) were 7.2%, and 5.0%, respectively. The accuracy of the developed procedure was validated by the analysis of certified reference materials (TMDA-53.3 Fortified Water, TMDA-70 Fortified Water, SPS-WW2 Waste Water, NCSDC-73349 Bush Branches and Leaves) and by addition/recovery analysis. The quantitative recoveries were obtained for the analysis of certified reference materials and addition/recovery tests. The method was successfully applied to the analysis of cadmium and lead in water, food, cigarette and hair samples. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. The AlSi10Mg samples produced by selective laser melting: single track, densification, microstructure and mechanical behavior

    International Nuclear Information System (INIS)

    Wei, Pei; Wei, Zhengying; Chen, Zhen; Du, Jun; He, Yuyang; Li, Junfeng; Zhou, Yatong

    2017-01-01

    Highlights: • The thermal behavior of AlSi10Mg molten pool was analyzed. • The SLM-processed sample with a relatively low surface roughness was obtained. • Effects of parameters on surface topography of scan track were investigated. • Effects of parameters on microstructure of parts were investigated. • Optimum processing parameters for AlSi10Mg SLM was obtained. - Abstract: This densification behavior and attendant microstructural characteristics of the selective laser melting (SLM) processed AlSi10Mg alloy affected by the processing parameters were systematically investigated. The samples with a single track were produced by SLM to study the influences of laser power and scanning speed on the surface morphologies of scan tracks. Additionally, the bulk samples were produced to investigate the influence of the laser power, scanning speed, and hatch spacing on the densification level and the resultant microstructure. The experimental results showed that the level of porosity of the SLM-processed samples was significantly governed by energy density of laser beam and the hatch spacing. The tensile properties of SLM-processed samples and the attendant fracture surface can be enhanced by decreasing the level of porosity. The microstructure of SLM-processed samples consists of supersaturated Al-rich cellular structure along with eutectic Al/Si situated at the cellular boundaries. The Si content in the cellular boundaries increases with increasing the laser power and decreasing the scanning speed. The hardness of SLM-processed samples was significantly improved by this fine microstructure compared with the cast samples. Moreover, the hardness of SLM-processed samples at overlaps was lower than the hardness observed at track cores.

  14. The AlSi10Mg samples produced by selective laser melting: single track, densification, microstructure and mechanical behavior

    Energy Technology Data Exchange (ETDEWEB)

    Wei, Pei; Wei, Zhengying, E-mail: zywei@mail.xjtu.edu.cn; Chen, Zhen; Du, Jun; He, Yuyang; Li, Junfeng; Zhou, Yatong

    2017-06-30

    Highlights: • The thermal behavior of AlSi10Mg molten pool was analyzed. • The SLM-processed sample with a relatively low surface roughness was obtained. • Effects of parameters on surface topography of scan track were investigated. • Effects of parameters on microstructure of parts were investigated. • Optimum processing parameters for AlSi10Mg SLM was obtained. - Abstract: This densification behavior and attendant microstructural characteristics of the selective laser melting (SLM) processed AlSi10Mg alloy affected by the processing parameters were systematically investigated. The samples with a single track were produced by SLM to study the influences of laser power and scanning speed on the surface morphologies of scan tracks. Additionally, the bulk samples were produced to investigate the influence of the laser power, scanning speed, and hatch spacing on the densification level and the resultant microstructure. The experimental results showed that the level of porosity of the SLM-processed samples was significantly governed by energy density of laser beam and the hatch spacing. The tensile properties of SLM-processed samples and the attendant fracture surface can be enhanced by decreasing the level of porosity. The microstructure of SLM-processed samples consists of supersaturated Al-rich cellular structure along with eutectic Al/Si situated at the cellular boundaries. The Si content in the cellular boundaries increases with increasing the laser power and decreasing the scanning speed. The hardness of SLM-processed samples was significantly improved by this fine microstructure compared with the cast samples. Moreover, the hardness of SLM-processed samples at overlaps was lower than the hardness observed at track cores.

  15. Sequence-specific detection of different strains of LCMV in a single sample using tentacle probes.

    Science.gov (United States)

    Franco, Lina S; Holechek, Susan A; Caplan, Michael R; Blattman, Joseph N

    2017-10-13

    Virus infections often result in quasispecies of viral strains that can have dramatic impacts on disease outcomes. However, sequencing of viruses to determine strain composition is time consuming and often cost-prohibitive. Rapid, cost-effective methods are needed for accurate measurement of virus diversity to understand virus evolution and can be useful for experimental systems. We have developed a novel molecular method for sequence-specific detection of RNA virus genetic variants called Tentacle Probes. The probes are modified molecular beacons that have dramatically improved false positive rates and specificity in routine qPCR. To validate this approach, we have designed Tentacle Probes for two different strains of Lymphocytic Choriomeningitis Virus (LCMV) that differ by only 3 nucleotide substitutions, the parental Armstrong and the more virulent Clone-13 strain. One of these mutations is a missense mutation in the receptor protein GP1 that leads to the Armstrong strain to cause an acute infection and Clone-13 to cause a chronic infection instead. The probes were designed using thermodynamic calculations for hybridization between target or non-target sequences and the probe. Using this approach, we were able to distinguish these two strains of LCMV individually by a single nucleotide mutation. The assay showed high reproducibility among different concentrations of viral cDNA, as well as high specificity and sensitivity, especially for the Clone-13 Tentacle Probe. Furthermore, in virus mixing experiments we were able to detect less than 10% of Clone-13 cDNA diluted in Armstrong cDNA. Thus, we have developed a fast, cost-effective approach for identifying Clone-13 strain in a mix of other LCMV strains.

  16. Quantitative chiral and achiral determination of ketamine and its metabolites by LC-MS/MS in human serum, urine and fecal samples.

    Science.gov (United States)

    Hasan, Mahmoud; Hofstetter, Robert; Fassauer, Georg M; Link, Andreas; Siegmund, Werner; Oswald, Stefan

    2017-05-30

    Ketamine (KET) is a widely used anesthetic drug which is metabolized by CYP450 enzymes to norketamine (n-KET), dehydronorketamine (DHNK), hydroxynorketamine (HNK) and hydroxyketamine (HK). Ketamine is a chiral compound and S-ketamine is known to be the more potent enantiomer. Here, we present the development and validation of three LC-MS/MS assays; the first for the quantification of racemic KET, n-KET and DHNK in human serum, urine and feces; the second for the separation and quantification of the S- and R-enantiomers of KET, n-KET and DHNK, and the third for separation and quantification of 2S,6S-hydroxynorketamine (2S,6S-HNK) and 2R,6R-hydroxynorketamine (2R,6R-HNK) in serum and urine with the ability to separate and detect 10 additional hydroxylated norketamine metabolites of racemic ketamine. Sample preparation was done by liquid-liquid extraction using methyl tert-butyl ether. For achiral determination of KET and its metabolites, an isocratic elution with ammonium acetate (pH 3.8; 5mM) and acetonitrile on a C18 column was performed. For the separation of S- and R-enantiomers of KET, n-KET and DHNK, a gradient elution was applied using a mobile phase of ammonium acetate (pH 7.5; 10mM) and isopropanol on the CHIRAL-AGP ® column. The enantioselective separation of the HNK metabolites was done on the chiral column Lux ® -Amylose-2 with a gradient method using ammonium acetate (pH 9; 5mM) and a mixture of isopropanol and acetonitrile (4:1). The mass spectrometric detection monitored for each analyte 2-3 mass/charge transitions. D4-ketamine and D4-n-KET were used as internal standards. The assays were successfully validated according to current bioanalytical guidelines and applied to a pilot study in one healthy volunteer. Compared to previously published methods, our assays have superior analytical features such as a lower amount of required matrix, faster sample preparation, shorter analytical run time and higher sensitivity (LLOQ up to 0.1ng/ml). Moreover, our

  17. Polychlorinated Biphenyl and Organochlorine Pesticide Concentrations in Maternal Mid-Pregnancy Serum Samples: Association with Autism Spectrum Disorder and Intellectual Disability.

    Science.gov (United States)

    Lyall, Kristen; Croen, Lisa A; Sjödin, Andreas; Yoshida, Cathleen K; Zerbo, Ousseny; Kharrazi, Martin; Windham, Gayle C

    2017-03-01

    Polychlorinated biphenyls (PCBs) and organochlorine pesticides (OCPs) are neurodevelopmental toxicants, but few studies have examined associations with autism spectrum disorder (ASD). We aimed to determine whether prenatal exposure to PCBs and OCPs influences offspring risk of ASD and intellectual disability without autism (ID). We conducted a population-based case-control study among Southern California births, including children with ASD ( n = 545) meeting Diagnostic and Statistical Manual of Mental Disorders, 4th Edition (DSM-IV-TR) criteria and ID ( n = 181), as well as general population (GP) controls ( n = 418). Concentrations of 11 PCB congeners and 2 OCPs measured in banked second-trimester serum samples were compared between the diagnostic groups. Logistic regression was used to calculate crude and adjusted odds ratios (AOR) for associations with ASD, and separately for ID, compared with GP controls, by quartiles of analyte concentrations in primary analyses. Geometric mean levels of several PCB congeners were higher in the ASD group than in the ID and GP groups. ASD risk was elevated for a number of PCB congeners, particularly for the highest vs. lowest quartile of PCB138/158 (AOR = 1.79; 95% CI: 1.10, 2.71) and PCB153 (AOR = 1.82; 95% CI: 1.10, 3.02), and for highest deciles of other congeners in secondary analyses. PCB138/158 was also associated with increased ID (AOR = 2.41; 95% CI: 1.18, 4.91), though no trend was suggested. OCPs were not associated with increased risk of ASD in primary analyses, whereas nonmonotonic increases in risk of ID were found with p,p ´-DDE. Our results suggest higher levels of some organochlorine compounds during pregnancy are associated with ASD and ID. Citation: Lyall K, Croen LA, Sjödin A, Yoshida CK, Zerbo O, Kharrazi M, Windham GC. 2017. Polychlorinated biphenyl and organochlorine pesticide concentrations in maternal mid-pregnancy serum samples: association with autism spectrum disorder and intellectual disability

  18. An in vitro tag-and-modify protein sample generation method for single-molecule fluorescence resonance energy transfer.

    Science.gov (United States)

    Hamadani, Kambiz M; Howe, Jesse; Jensen, Madeleine K; Wu, Peng; Cate, Jamie H D; Marqusee, Susan

    2017-09-22

    Biomolecular systems exhibit many dynamic and biologically relevant properties, such as conformational fluctuations, multistep catalysis, transient interactions, folding, and allosteric structural transitions. These properties are challenging to detect and engineer using standard ensemble-based techniques. To address this drawback, single-molecule methods offer a way to access conformational distributions, transient states, and asynchronous dynamics inaccessible to these standard techniques. Fluorescence-based single-molecule approaches are parallelizable and compatible with multiplexed detection; to date, however, they have remained limited to serial screens of small protein libraries. This stems from the current absence of methods for generating either individual dual-labeled protein samples at high throughputs or protein libraries compatible with multiplexed screening platforms. Here, we demonstrate that by combining purified and reconstituted in vitro translation, quantitative unnatural amino acid incorporation via AUG codon reassignment, and copper-catalyzed azide-alkyne cycloaddition, we can overcome these challenges for target proteins that are, or can be, methionine-depleted. We present an in vitro parallelizable approach that does not require laborious target-specific purification to generate dual-labeled proteins and ribosome-nascent chain libraries suitable for single-molecule FRET-based conformational phenotyping. We demonstrate the power of this approach by tracking the effects of mutations, C-terminal extensions, and ribosomal tethering on the structure and stability of three protein model systems: barnase, spectrin, and T4 lysozyme. Importantly, dual-labeled ribosome-nascent chain libraries enable single-molecule co-localization of genotypes with phenotypes, are well suited for multiplexed single-molecule screening of protein libraries, and should enable the in vitro directed evolution of proteins with designer single-molecule conformational

  19. A review of single-sample-based models and other approaches for radiocarbon dating of dissolved inorganic carbon in groundwater

    Science.gov (United States)

    Han, L. F; Plummer, Niel

    2016-01-01

    Numerous methods have been proposed to estimate the pre-nuclear-detonation 14C content of dissolved inorganic carbon (DIC) recharged to groundwater that has been corrected/adjusted for geochemical processes in the absence of radioactive decay (14C0) - a quantity that is essential for estimation of radiocarbon age of DIC in groundwater. The models/approaches most commonly used are grouped as follows: (1) single-sample-based models, (2) a statistical approach based on the observed (curved) relationship between 14C and δ13C data for the aquifer, and (3) the geochemical mass-balance approach that constructs adjustment models accounting for all the geochemical reactions known to occur along a groundwater flow path. This review discusses first the geochemical processes behind each of the single-sample-based models, followed by discussions of the statistical approach and the geochemical mass-balance approach. Finally, the applications, advantages and limitations of the three groups of models/approaches are discussed.The single-sample-based models constitute the prevailing use of 14C data in hydrogeology and hydrological studies. This is in part because the models are applied to an individual water sample to estimate the 14C age, therefore the measurement data are easily available. These models have been shown to provide realistic radiocarbon ages in many studies. However, they usually are limited to simple carbonate aquifers and selection of model may have significant effects on 14C0 often resulting in a wide range of estimates of 14C ages.Of the single-sample-based models, four are recommended for the estimation of 14C0 of DIC in groundwater: Pearson's model, (Ingerson and Pearson, 1964; Pearson and White, 1967), Han & Plummer's model (Han and Plummer, 2013), the IAEA model (Gonfiantini, 1972; Salem et al., 1980), and Oeschger's model (Geyh, 2000). These four models include all processes considered in single-sample-based models, and can be used in different ranges of

  20. Does the time interval between antimüllerian hormone serum sampling and initiation of ovarian stimulation affect its predictive ability in in vitro fertilization-intracytoplasmic sperm injection cycles with a gonadotropin-releasing hormone antagonist?

    DEFF Research Database (Denmark)

    Polyzos, Nikolaos P; Nelson, Scott M; Stoop, Dominic

    2013-01-01

    To investigate whether the time interval between serum antimüllerian hormone (AMH) sampling and initiation of ovarian stimulation for in vitro fertilization-intracytoplasmic sperm injection (IVF-ICSI) may affect the predictive ability of the marker for low and excessive ovarian response.......To investigate whether the time interval between serum antimüllerian hormone (AMH) sampling and initiation of ovarian stimulation for in vitro fertilization-intracytoplasmic sperm injection (IVF-ICSI) may affect the predictive ability of the marker for low and excessive ovarian response....

  1. A safety equipment list for rotary mode core sampling systems operation in single shell flammable gas tanks

    International Nuclear Information System (INIS)

    SMALLEY, J.L.

    1999-01-01

    This document identifies all interim safety equipment to be used for rotary mode core sampling of single-shell flammable gas tanks utilizing Rotary Mode Core Sampling systems (RMCS). This document provides the safety equipment for RMCS trucks HO-68K-4600, HO-68K-4647, trucks three and four respectively, and associated equipment. It is not intended to replace or supersede WHC-SD-WM-SEL-023, (Kelly 1991), or WHC-SD-WM-SEL-032, (Corbett 1994), which classifies 80-68K-4344 and HO-68K-4345 respectively. The term ''safety equipment'' refers to safety class (SC) and safety significant (SS) equipment, where equipment refers to structures, systems and components (SSC's). The identification of safety equipment in this document is based on the credited design safety features and analysis contained in the Authorization Basis (AB) for rotary mode core sampling operations in single-shell flammable gas tanks. This is an interim safety classification since the AB is interim. This document will be updated to reflect the final RMCS equipment safety classification designations upon completion of a final AB which will be implemented with the release of the Final Safety Analysis Report (FSAR)

  2. Frequency of single nucleotide polymorphisms of some immune response genes in a population sample from São Paulo, Brazil

    Directory of Open Access Journals (Sweden)

    Léa Campos de Oliveira

    2011-09-01

    Full Text Available Objective: To present the frequency of single nucleotide polymorphismsof a few immune response genes in a population sample from SãoPaulo City (SP, Brazil. Methods: Data on allele frequencies ofknown polymorphisms of innate and acquired immunity genes werepresented, the majority with proven impact on gene function. Datawere gathered from a sample of healthy individuals, non-HLA identicalsiblings of bone marrow transplant recipients from the Hospital dasClínicas da Faculdade de Medicina da Universidade de São Paulo,obtained between 1998 and 2005. The number of samples variedfor each single nucleotide polymorphism analyzed by polymerasechain reaction followed by restriction enzyme cleavage. Results:Allele and genotype distribution of 41 different gene polymorphisms,mostly cytokines, but also including other immune response genes,were presented. Conclusion: We believe that the data presentedhere can be of great value for case-control studies, to define whichpolymorphisms are present in biologically relevant frequencies and toassess targets for therapeutic intervention in polygenic diseases witha component of immune and inflammatory responses.

  3. The prognostic role of preoperative and (early) postoperatively change in CA15.3 serum levels in a single hospital cohort of primary operable breast cancers.

    Science.gov (United States)

    Brouckaert, O; Laenen, A; Wildiers, H; Floris, G; Moerman, P; Van Limbergen, E; Vergote, I; Billen, J; Christiaens, M R; Neven, P

    2013-06-01

    Measuring CA15.3 serum levels in the early breast cancer setting is not recommended by current ASCO guidelines. In this large single center study, we assess the prognostic value of preoperative (n = 3746), postoperative (n = 4049) and change in (n = 3252) CA15.3, also across different breast cancer phenotypes. Preoperative, postoperative and change in CA15.3 were all significant (p = 0.0348, p < 0.0001, p < 0.0001 respectively in multivariate analysis) predictors of distant metastasis free survival. For breast cancer specific survival, only postoperative and change in CA15.3 were significant predictors (p < 0.0001 both). Multivariate prognostic models did not improve by incorporating information on preoperative CA15.3, but did improve when introducing information on postoperative CA15.3 for distant metastasis (p = 0.0365) and on change in CA15.3 for breast cancer specific survival (p = 0.0291). Change in CA15.3 impacts on prognosis (distant metastasis) differently in different breast cancer phenotypes. A decrease in CA15.3 may be informative of improved prognosis in basal like and HER2 like breast cancer. Copyright © 2013 Elsevier Ltd. All rights reserved.

  4. Oral pathology follow-up by means of micro-Raman spectroscopy on tissue and blood serum samples: an application of wavelet and multivariate data analysis

    Science.gov (United States)

    Delfino, I.; Camerlingo, C.; Zenone, F.; Perna, G.; Capozzi, V.; Cirillo, N.; Gaeta, G. M.; De Mol, E.; Lepore, M.

    2009-02-01

    Pemphigus vulgaris (PV) is a potentially fatal autoimmune disease that cause blistering of the skin and oral cavity. It is characterized by disruption of cell-cell adhesion within the suprabasal layers of epithelium, a phenomenon termed acantholysis Patients with PV develop IgG autoantibodies against normal constituents of the intercellular substance of keratinocytes. The mechanisms by which such autoantibodies induce blisters are not clearly understood. The qualitative analysis of such effects provides important clues in the search for a specific diagnosis, and the quantitative analysis of biochemical abnormalities is important in measuring the extent of the disease process, designing therapy and evaluating the efficacy of treatment. Improved diagnostic techniques could permit the recognition of more subtle forms of disease and reveal incipient lesions clinically unapparent, so that progression of potentially severe forms could be reversed with appropriate treatment. In this paper, we report the results of our micro-Raman spectroscopy study on tissue and blood serum samples from ill, recovered and under therapy PV patients. The complexity of the differences among their characteristic Raman spectra has required a specific strategy to obtain reliable information on the illness stage of the patients For this purpose, wavelet techniques and advanced multivariate analysis methods have been developed and applied to the experimental Raman spectra. Promising results have been obtained.

  5. [Detection of serum proteins in the patients of lung adenocarcinoma by the method of magnetic bead based sample fractionation and MALDI-TOF-MS].

    Science.gov (United States)

    Liu, Dan; Liu, Lun-Xu; Yuan, Quan; Li, Xiao-Liang; Huang, Na; Yang, Xiao-Dong

    2010-05-01

    To screen the serum proteins related to human lung adenocarcinoma using matrix-assisted laser desorption/ionization time of flight mass spectrometry (MALDI-TOF-MS) technology. The blood samples were collected from 10 patients of lung adenocarcinoma before and one week after the surgery, while 10 healthy subjects were used as control. The differential protein expression between the two groups and the change of those proteins after surgery were studied by ClinProt magnetic bead enrichment and MALDI-TOF-MS. Six protein peaks were identified, 2 of them were highly expressed protein biomarkers with relative molecular weights of 2661, 2991, and increased after the surgery, 4 of them were lowly expressed protein biomarkers with relative molecular weights of 4091, 4210, 4644, 5336, which continuously decreased after the surgery. ClinProt magnetic bead enrichment and MALDI-TOF-MS is a quick, easy and sensitive method of proteomics. The differential expressed proteins may be the latent tumor marker of lung adenocarcinoma. The alteration of those proteins after surgery might be helpful to assess the therapeutic effect and prognosis.

  6. Binding characteristics of homogeneous molecularly imprinted polymers for acyclovir using an (acceptor-donor-donor)-(donor-acceptor-acceptor) hydrogen-bond strategy, and analytical applications for serum samples.

    Science.gov (United States)

    Wu, Suqin; Tan, Lei; Wang, Ganquan; Peng, Guiming; Kang, Chengcheng; Tang, Youwen

    2013-04-12

    This paper demonstrates a novel approach to assembling homogeneous molecularly imprinted polymers (MIPs) based on mimicking multiple hydrogen bonds between nucleotide bases by preparing acyclovir (ACV) as a template and using coatings grafted on silica supports. (1)H NMR studies confirmed the AAD-DDA (A for acceptor, D for donor) hydrogen-bond array between template and functional monomer, while the resultant monodisperse molecularly imprinted microspheres (MIMs) were evaluated using a binding experiment, high performance liquid chromatography (HPLC), and solid phase extraction. The Langmuir isothermal model and the Langmuir-Freundlich isothermal model suggest that ACV-MIMs have more homogeneous binding sites than MIPs prepared through normal imprinting. In contrast to previous MIP-HPLC columns, there were no apparent tailings for the ACV peaks, and ACV-MIMs had excellent specific binding properties with a Ka peak of 3.44 × 10(5)M(-1). A complete baseline separation is obtained for ACV and structurally similar compounds. This work also successfully used MIMs as a specific sorbent for capturing ACV from serum samples. The detection limit and mean recovery of ACV was 1.8 ng/mL(-1) and 95.6%, respectively, for molecularly imprinted solid phase extraction coupled with HPLC. To our knowledge, this was the first example of MIPs using AAD-DDA hydrogen bonds. Copyright © 2013 Elsevier B.V. All rights reserved.

  7. Sensitive and selective spectrophotometric assay of piroxicam in pure form, capsule and human blood serum samples via ion-pair complex formation

    Science.gov (United States)

    Alizadeh, Nina; Keyhanian, Fereshteh

    2014-09-01

    A simple, accurate and highly sensitive spectrophotometric method has been developed for the rapid determination of piroxicam (PX) in pure and pharmaceutical formulations. The proposed method involves formation of stable yellow colored ion-pair complexes of the amino derivative (basic nitrogen) of PX with three sulphonphthalein acid dyes namely; bromocresol green (BCG), bromothymol blue (BTB), bromophenol blue (BPB) in acidic medium. The colored species exhibited absorption maxima at 438, 429 and 432 nm with molar absorptivity values of 9.400 × 103, 1.218 × 103 and 1.02 × 104 L mol-1 cm-1 for PX-BCG, PX-BTB and PX-BPB complexes, respectively. The effect of optimum conditions via acidity, reagent concentration, time and solvent were studied. The reactions were extremely rapid at room temperature and the absorbance values remained constant for 48 h. Beer’s law was obeyed with a good correlation coefficient in the concentration ranges 1-100 μg mL-1 for BCG, BTB complexes and 1-95 μg mL-1 for BPB complex. The composition ratio of the ion-pair complexes were found to be 1:1 in all cases as established by Job’s method. No interference was observed from common additives and excipients which may be present in the pharmaceutical preparations. The proposed method was successfully applied for the determination of PX in capsule and human blood serum samples with good accuracy and precision.

  8. Amplified voltammetric detection of miRNA from serum samples of glioma patients via combination of conducting magnetic microbeads and ferrocene-capped gold nanoparticle/streptavidin conjugates.

    Science.gov (United States)

    Lu, Zhixuan; Tang, Hailin; Wu, Daohong; Xia, Yonghong; Wu, Minghua; Yi, Xinyao; Li, Hengfeng; Wang, Jianxiu

    2016-12-15

    MicroRNA (miRNA) plays a key regulatory role in many biological processes, emerging as an important biomarker for a large variety of cancer diseases. Employing gold nanoparticle (AuNP)-coated magnetic microbeads (AuNP-MMBs) as an immobilization matrix for higher loading density of hairpin-structured DNA probes and then ferrocene (Fc)-capped gold nanoparticle/streptavidin conjugates, amplified electrochemical assay of miRNA has been performed. In the presence of target miRNA, a novel assembly was formed via linking biotinylated hairpin DNA probe-covered AuNP-MMBs with Fc-capped gold nanoparticle/streptavidin conjugates and then collected by magnetic electrodes for voltammetric detection. The enlarged surface area, good conductivity of AuNP-MMBs and the multiple Fc tags on the electrode surface ensure high sensitivity of the method. The oxidation peak current of Fc tags is proportional to the concentrations of miRNA ranging from 5 fM to 100 fM, and a detection limit of 0.14 fM was achieved. The proposed assay is highly selective and reproducible, serving as a viable alternative for the detection of miRNA-182 from serum samples of glioma patients. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. Bayesian Estimation of the True Prevalence and of the Diagnostic Test Sensitivity and Specificity of Enteropathogenic Yersinia in Finnish Pig Serum Samples

    Directory of Open Access Journals (Sweden)

    M. J. Vilar

    2015-01-01

    Full Text Available Bayesian analysis was used to estimate the pig’s and herd’s true prevalence of enteropathogenic Yersinia in serum samples collected from Finnish pig farms. The sensitivity and specificity of the diagnostic test were also estimated for the commercially available ELISA which is used for antibody detection against enteropathogenic Yersinia. The Bayesian analysis was performed in two steps; the first step estimated the prior true prevalence of enteropathogenic Yersinia with data obtained from a systematic review of the literature. In the second step, data of the apparent prevalence (cross-sectional study data, prior true prevalence (first step, and estimated sensitivity and specificity of the diagnostic methods were used for building the Bayesian model. The true prevalence of Yersinia in slaughter-age pigs was 67.5% (95% PI 63.2–70.9. The true prevalence of Yersinia in sows was 74.0% (95% PI 57.3–82.4. The estimates of sensitivity and specificity values of the ELISA were 79.5% and 96.9%.

  10. Hand-held optical sensor using denatured antibody coated electro-active polymer for ultra-trace detection of copper in blood serum and environmental samples.

    Science.gov (United States)

    Chandra, Sutapa; Dhawangale, Arvind; Mukherji, Soumyo

    2018-03-20

    An optimum copper concentration in environment is highly desired for all forms of life. We have developed an ultrasensitive copper sensor which functions from femto to micro molar concentration accurately (R 2 = 0.98). The sensor is based on denatured antibody immunoglobulin G (IgG), immobilized on polyaniline (PAni) which in turn is the coating on the core of an optical fiber. The sensing relies on changes in evanescent wave absorbance in the presence of the analyte. The sensor showed excellent selectivity towards Cu (II) ions over all other metal ions. The sensor was tested with lake and marine water samples to determine unknown concentrations of copper ions and the recovery results were within 90-115%, indicating reasonable accuracy. We further integrated the fiber-optic sensor with a miniaturized hand-held instrumentation platform to develop an accurate and field deployable device which can broadly be applicable to determine Cu (II) concentration in a wide range of systems - natural water bodies, soil as well as blood serum. Copyright © 2018 Elsevier B.V. All rights reserved.

  11. Versatile lipid profiling by liquid chromatography-high resolution mass spectrometry using all ion fragmentation and polarity switching. Preliminary application for serum samples phenotyping related to canine mammary cancer.

    Science.gov (United States)

    Gallart-Ayala, H; Courant, F; Severe, S; Antignac, J-P; Morio, F; Abadie, J; Le Bizec, B

    2013-09-24

    Lipids represent an extended class of substances characterized by such high variety and complexity that makes their unified analyses by liquid chromatography coupled to either high resolution or tandem mass spectrometry (LC-HRMS or LC-MS/MS) a real challenge. In the present study, a new versatile methodology associating ultra high performance liquid chromatography coupled to high resolution tandem mass spectrometry (UHPLC-HRMS/MS) have been developed for a comprehensive analysis of lipids. The use of polarity switching and "all ion fragmentation" (AIF) have been two action levels particularly exploited to finally permit the detection and identification of a multi-class and multi-analyte extended range of lipids in a single run. For identification purposes, both higher energy collision dissociation (HCD) and in-source CID (collision induced dissociation) fragmentation were evaluated in order to obtain information about the precursor and product ions in the same spectra. This approach provides both class-specific and lipid-specific fragments, enhancing lipid identification. Finally, the developed method was applied for differential phenotyping of serum samples collected from pet dogs developing spontaneous malignant mammary tumors and health controls. A biological signature associated with the presence of cancer was then successfully revealed from this lipidome analysis, which required to be further investigated and confirmed at larger scale. Copyright © 2013 Elsevier B.V. All rights reserved.

  12. Evaluation of mixing downstream of tees in duct systems with respect to single point representative air sampling.

    Science.gov (United States)

    Kim, Taehong; O'Neal, Dennis L; Ortiz, Carlos

    2006-09-01

    Air duct systems in nuclear facilities must be monitored with continuous sampling in case of an accidental release of airborne radionuclides. The purpose of this work is to identify the air sampling locations where the velocity and contaminant concentrations fall below the 20% coefficient of variation required by the American National Standards Institute/Health Physics Society N13.1-1999. Experiments of velocity and tracer gas concentration were conducted on a generic "T" mixing system which included combinations of three sub ducts, one main duct, and air velocities from 0.5 to 2 m s (100 to 400 fpm). The experimental results suggest that turbulent mixing provides the accepted velocity coefficients of variation after 6 hydraulic diameters downstream of the T-junction. About 95% of the cases achieved coefficients of variation below 10% by 6 hydraulic diameters. However, above a velocity ratio (velocity in the sub duct/velocity in the main duct) of 2, velocity profiles were uniform in a shorter distance downstream of the T-junction as the velocity ratio went up. For the tracer gas concentration, the distance needed for the coefficients of variation to drop 20% decreased with increasing velocity ratio due to the sub duct airflow momentum. The results may apply to other duct systems with similar geometries and, ultimately, be a basis for selecting a proper sampling location under the requirements of single point representative sampling.

  13. Single-layer centrifugation separates spermatozoa from diploid cells in epididymal samples from gray wolves, Canis lupus (L.).

    Science.gov (United States)

    Muñoz-Fuentes, Violeta; Linde Forsberg, Catharina; Vilà, Carles; Morrell, Jane M

    2014-09-15

    Sperm samples may be used for assisted reproductive technologies (e.g., farmed or endangered species) or as a source of haploid DNA or sperm-specific RNA. When ejaculated spermatozoa are not available or are very difficult to obtain, as is the case for most wild endangered species, the epididymides of dead animals (e.g., animals that have been found dead, shot by hunters or poachers, or that that require euthanasia in zoological collections) can be used as a source of sperm. Such epididymal sperm samples are usually contaminated with cellular debris, erythrocytes, leukocytes, and sometimes also bacteria. These contaminants may be sources of reactive oxygen species that damage spermatozoa during freezing or contribute undesired genetic material from diploid cells. We used single-layer centrifugation through a colloid formulation, Androcoll-C, to successfully separate wolf epididymal spermatozoa from contaminating cells and cellular debris in epididymal samples harvested from carcasses. Such a procedure may potentially be applied to epididymal sperm samples from other species. Copyright © 2014 Elsevier Inc. All rights reserved.

  14. Mixed infection and clonal representativeness of a single sputum sample in tuberculosis patients from a penitentiary hospital in Georgia

    Directory of Open Access Journals (Sweden)

    Portaels Françoise

    2006-07-01

    Full Text Available Abstract Background Studies on recurrent tuberculosis (TB, TB molecular epidemiology and drug susceptibility testing rely on the analysis of one Mycobacterium tuberculosis isolate from a single sputum sample collected at different disease episodes. This scheme rests on the postulate that a culture of one sputum sample is homogeneous and representative of the total bacillary population in a patient. Methods We systematically analysed several pre-treatment isolates from each of 199 smear-positive male adult inmates admitted to a prison TB hospital by standard IS6110 DNA fingerprinting, followed by PCR typing based on multiple loci containing variable number of tandem repeats (VNTRs on a subset of isolates. Drug susceptibility testing (DST was performed on all isolates for isoniazid, rifampicin, streptomycin and ethambutol. Results We found mixed infection in 26 (13.1% cases. In contrast, analysis of a single pre-treatment isolate per patient would have led to missed mixed infections in all or 14 of these 26 cases by using only standard DNA fingerprinting or the PCR multilocus-based method, respectively. Differences in DST among isolates from the same patient were observed in 10 cases, of which 6 were from patients with mixed infection. Conclusion These results suggest that the actual heterogeneity of the bacillary population in patients, especially in high TB incidence settings, may be frequently underestimated using current analytical schemes. These findings have therefore important implications for correct interpretation and evaluation of molecular epidemiology data and in treatment evaluations.

  15. Survey of serum concentrations of dioxins, furans, and coplanar polychlorinated biphenyls in a small non-random sample of U.S. residents

    Energy Technology Data Exchange (ETDEWEB)

    Grassman, J. [Brooklyn Coll. CUNY, Health and Nutrition Sciences, Brooklyn, New York, NY (United States); Patterson, D.G. Jr.; Needham, L.L. [National Center for Environmental Health, Centers for Disease Control and Prevention, Atlanta, GA (United States); Spencer, D.L.; Masten, S.A. [Environmental Toxicology Program, National Inst. of Environmental Health Sciences, Research Triangle Park, NC (United States)

    2004-09-15

    This cross sectional assessment of serum dioxin concentrations was conducted as part of a larger study to examine the relationship between dioxin exposure and gene expression in peripheral blood mononuclear cells. Recent reports indicate that environmental levels of dioxins have declined since the mid-1980's. Except for the recent National Health and Nutrition Examination Survey (NHANES), there has been little systematic surveillance of serum dioxins levels in the US general population. Here, we report the serum concentrations of 22 congeners of dioxins and dioxin-like compounds and their relationship with age, sex, smoking, and meat consumption.

  16. Rapid detection of cytomegalovirus in bronchoalveolar lavage fluid and serum samples by polymerase chain reaction: correlation of virus isolation and clinical outcome for patients with human immunodeficiency virus infection

    DEFF Research Database (Denmark)

    Hansen, K K; Vestbo, Jørgen; Benfield, T

    1997-01-01

    Bronchoalveolar lavage (BAL) fluids and serum samples from 153 patients with pulmonary symptoms who were infected with human immunodeficiency virus (HIV) and underwent BAL were examined for the presence of cytomegalovirus (CMV) by conventional culture and by polymerase chain reaction (PCR...

  17. Development of a novel method for simultaneous concentration of viruses and protozoa from a single water sample.

    Science.gov (United States)

    Haramoto, Eiji; Katayama, Hiroyuki; Asami, Mari; Akiba, Michihiro

    2012-06-01

    A novel method, electronegative membrane-vortex (EMV) method, was developed for simultaneous concentration of viruses and protozoa from a single water sample. Viruses and protozoa in a water sample were mixed with a cation solution and adsorbed on an electronegative membrane. Concentrated virus and protozoa samples were obtained as supernatant and pellet fractions, respectively, by vigorous vortex mixing of the membrane and centrifugation of the eluted material. The highest recovery efficiencies of model microbes from river water and tap water by this EMV method were obtained using a mixed cellulose ester membrane with a pore size of 0.45 μm (Millipore) as the electronegative membrane and MgCl(2) as the cation solution. The recovery was 27.7-86.5% for poliovirus, 25.7-68.3% for coliphage Qβ, 28.0-60.0% for Cryptosporidium oocysts, and 35.0-53.0% for Giardia cysts. The EMV method detected successfully indigenous viruses and protozoa in wastewater and river water samples from the Kofu basin, Japan, showing an overall positive rate of 100% (43/43) for human adenovirus, 79% (34/43) for norovirus GI, 65% (28/43) for norovirus GII, 23% (10/43) for Cryptosporidium oocysts, and 60% (26/43) for Giardia cysts. By direct DNA sequencing, a total of four genotypes (AI, AII, B, and G) of Giardia intestinalis were identified in the water samples, indicating that the river water was contaminated with feces from various mammals, including humans. Copyright © 2012 Elsevier B.V. All rights reserved.

  18. Optimization of plasma sampling depth and aerosol gas flow rates for single particle inductively coupled plasma mass spectrometry analysis.

    Science.gov (United States)

    Kálomista, Ildikó; Kéri, Albert; Galbács, Gábor

    2017-09-01

    We performed experiments to assess the separate and also the combined effect of the sampling depth and the aerosol gas flow rates on the signal formation in single particle inductively coupled plasma mass spectrometry (spICP-MS) measurements by using dispersions containing Ag and Au NPs. It was found that the NP signal can significantly be improved by the optimization of the sampling depth. With respect to the "robust" setting, a signal improvement of nearly 100% could be achieved, which translates into a 25-30% improvement in size detection limits. It was also found that the shape of the spICP-MS signal histograms also change with the change of the plasma sampling depth. It was demonstrated that nanoparticle peak separation can also be significantly enhanced by using sampling depth optimization. The effect of the aerosol dilution gas flow, now standard in most ICP-MS instruments, on the spICP-MS signal formation was also studied for the first time in the literature, as this flow was hoped to make spICP-MS measurements more practical and faster via the on-line dilution of the aerosol generated from nano-dispersions. Our experimental results revealed that the dilution gas flow can only be used for a moderate aerosol dilution in spICP-MS measurements, if the gas flow going to the pneumatic nebulizer is proportionally lowered at the same time. This however was found to cause a significant worsening in the operation of the sample introduction system, which gives rise to a strong NP signal loss. Thus it was concluded that the use of the aerosol dilution gas flow, in its present form, can not be suggested for spICP-MS analysis. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. A Simple Fractionated Extraction Method for the Comprehensive Analysis of Metabolites, Lipids, and Proteins from a Single Sample.

    Science.gov (United States)

    Salem, Mohamed; Bernach, Michal; Bajdzienko, Krzysztof; Giavalisco, Patrick

    2017-06-01

    Understanding of complex biological systems requires the measurement, analysis and integration of multiple compound classes of the living cell, usually determined by transcriptomic, proteomic, metabolomics and lipidomic measurements. In this protocol, we introduce a simple method for the reproducible extraction of metabolites, lipids and proteins from biological tissues using a single aliquot per sample. The extraction method is based on a methyl tert-butyl ether: methanol: water system for liquid: liquid partitioning of hydrophobic and polar metabolites into two immiscible phases along with the precipitation of proteins and other macromolecules as a solid pellet. This method, therefore, provides three different fractions of specific molecular composition, which are fully compatible with common high throughput 'omics' technologies such as liquid chromatography (LC) or gas chromatography (GC) coupled to mass spectrometers. Even though the method was initially developed for the analysis of different plant tissue samples, it has proved to be fully compatible for the extraction and analysis of biological samples from systems as diverse as algae, insects, and mammalian tissues and cell cultures.

  20. Integrative analysis of single nucleotide polymorphisms and gene expression efficiently distinguishes samples from closely related ethnic populations

    Directory of Open Access Journals (Sweden)

    Yang Hsin-Chou

    2012-07-01

    Full Text Available Abstract Background Ancestry informative markers (AIMs are a type of genetic marker that is informative for tracing the ancestral ethnicity of individuals. Application of AIMs has gained substantial attention in population genetics, forensic sciences, and medical genetics. Single nucleotide polymorphisms (SNPs, the materials of AIMs, are useful for classifying individuals from distinct continental origins but cannot discriminate individuals with subtle genetic differences from closely related ancestral lineages. Proof-of-principle studies have shown that gene expression (GE also is a heritable human variation that exhibits differential intensity distributions among ethnic groups. GE supplies ethnic information supplemental to SNPs; this motivated us to integrate SNP and GE markers to construct AIM panels with a reduced number of required markers and provide high accuracy in ancestry inference. Few studies in the literature have considered GE in this aspect, and none have integrated SNP and GE markers to aid classification of samples from closely related ethnic populations. Results We integrated a forward variable selection procedure into flexible discriminant analysis to identify key SNP and/or GE markers with the highest cross-validation prediction accuracy. By analyzing genome-wide SNP and/or GE markers in 210 independent samples from four ethnic groups in the HapMap II Project, we found that average testing accuracies for a majority of classification analyses were quite high, except for SNP-only analyses that were performed to discern study samples containing individuals from two close Asian populations. The average testing accuracies ranged from 0.53 to 0.79 for SNP-only analyses and increased to around 0.90 when GE markers were integrated together with SNP markers for the classification of samples from closely related Asian populations. Compared to GE-only analyses, integrative analyses of SNP and GE markers showed comparable testing

  1. Classifying the Progression of Ductal Carcinoma from Single-Cell Sampled Data via Integer Linear Programming: A Case Study.

    Science.gov (United States)

    Catanzaro, Daniele; Shackney, Stanley E; Schaffer, Alejandro A; Schwartz, Russell

    2016-01-01

    Ductal Carcinoma In Situ (DCIS) is a precursor lesion of Invasive Ductal Carcinoma (IDC) of the breast. Investigating its temporal progression could provide fundamental new insights for the development of better diagnostic tools to predict which cases of DCIS will progress to IDC. We investigate the problem of reconstructing a plausible progression from single-cell sampled data of an individual with synchronous DCIS and IDC. Specifically, by using a number of assumptions derived from the observation of cellular atypia occurring in IDC, we design a possible predictive model using integer linear programming (ILP). Computational experiments carried out on a preexisting data set of 13 patients with simultaneous DCIS and IDC show that the corresponding predicted progression models are classifiable into categories having specific evolutionary characteristics. The approach provides new insights into mechanisms of clonal progression in breast cancers and helps illustrate the power of the ILP approach for similar problems in reconstructing tumor evolution scenarios under complex sets of constraints.

  2. Development and validation of a rapid turboflow LC-MS/MS method for the quantification of LSD and 2-oxo-3-hydroxy LSD in serum and urine samples of emergency toxicological cases.

    Science.gov (United States)

    Dolder, Patrick C; Liechti, Matthias E; Rentsch, Katharina M

    2015-02-01

    Lysergic acid diethylamide (LSD) is a widely used recreational drug. The aim of the present study is to develop a quantitative turboflow LC-MS/MS method that can be used for rapid quantification of LSD and its main metabolite 2-oxo-3-hydroxy LSD (O-H-LSD) in serum and urine in emergency toxicological cases without time-consuming extraction steps. The method was developed on an ion-trap LC-MS/MS instrument coupled to a turbulent-flow extraction system. The validation data showed no significant matrix effects and no ion suppression has been observed in serum and urine. Mean intraday accuracy and precision for LSD were 101 and 6.84%, in urine samples and 97.40 and 5.89% in serum, respectively. For O-H-LSD, the respective values were 97.50 and 4.99% in urine and 107 and 4.70% in serum. Mean interday accuracy and precision for LSD were 100 and 8.26% in urine and 101 and 6.56% in serum, respectively. For O-H-LSD, the respective values were 101 and 8.11% in urine and 99.8 and 8.35% in serum, respectively. The lower limit of quantification for LSD was determined to be 0.1 ng/ml. LSD concentrations in serum were expected to be up to 8 ng/ml. 2-Oxo-3-hydroxy LSD concentrations in urine up to 250 ng/ml. The new method was accurate and precise in the range of expected serum and urine concentrations in patients with a suspected LSD intoxication. Until now, the method has been applied in five cases with suspected LSD intoxication where the intake of the drug has been verified four times with LSD concentrations in serum in the range of 1.80-14.70 ng/ml and once with a LSD concentration of 1.25 ng/ml in urine. In serum of two patients, the O-H-LSD concentration was determined to be 0.99 and 0.45 ng/ml. In the urine of a third patient, the O-H-LSD concentration was 9.70 ng/ml.

  3. Algorithm and program for precise determination of unit-cell parameters of single crystal taking into account the sample eccentricity

    Science.gov (United States)

    Dudka, A. P.; Smirnova, E. S.; Verin, I. A.; Bolotina, N. B.

    2017-07-01

    A technique has been developed to refine the unit-cell parameters of single crystals with minimization of the influence of instrumental errors on the result. The corresponding computational procedure HuberUB is added to the software package of Huber-5042 diffractometer with a point detector and closedcycle helium cryostat Displex DE-202. The parameters of unit cell, its orientation, the goniometer zero angles, the sample eccentricity, the distances in the goniometer, and the radiation wavelength were refined by the nonlinear least-squares method, which allows imposition of constraints on the unit-cell parameters, depending on the crystal symmetry. The technique is approved on a LuB12 single crystal. The unit-cell parameters are determined in a temperature range of 20-295 K, with an absolute error not larger than 0.0004 Å (the relative error is of 5 × 10-5). The estimates of the unit-cell parameters obtained by the proposed method are evidenced to be unbiased. Some specific features of the behavior of parameters in the ranges of 120-140 and 20-50 K are revealed, which correlate with the anomalies of the physical properties of the crystal.

  4. Serum concentrations of perfluorinated compounds (PFC) ...

    Science.gov (United States)

    Perfluorinated compounds (PFCs) have been widely used in industrial applications and consumer products. Their persistent nature and potential health impacts are of concern. Given the high cost of collecting serum samples, this study is to understand whether we can quantify PFC serum concentrations using factors extracted from questionnaire responses and indirect measurements, and whether a single serum measurement can be used to classify an individual′s exposure over a one-year period. The study population included three demographic groups: young children (2–8 years old) (N=67), parents of young children (55 years old) (N=59). PFC serum concentrations, house dust concentrations, and questionnaires were collected. The geometric mean of perfluorooctane sulfonic acid (PFOS) was highest for the older adults. In contrast, the geometric mean of perfluorooctanoic acid (PFOA) was highest for children. Serum concentrations of the parent and the child from the same family were moderately correlated (Spearman correlation (r)=0.26–0.79, padults, age, having occupational exposure or having used fire extinguisher, frequencies of consuming butter/margarine, pork, canned meat entrées, tuna and white fish, freshwater fish, and whether they ate microwave popcorn were significantly positively associated with serum concentrations of individual PFCs. For children, residential dust

  5. pH(stat) vs. single extraction tests to evaluate heavy metals and arsenic leachability in environmental samples.

    Science.gov (United States)

    Rigol, A; Mateu, J; González-Núñez, R; Rauret, G; Vidal, M

    2009-01-19

    Here we compared the pH(stat) test, which examines the leachability of major elements (Ca, Mg, Al, Fe, and Mn), dissolved organic carbon, and trace elements (Cd, Zn, Cu, Pb, and As) in a wide pH range, with single extraction tests based on the use of mild extractants (calcium chloride, acetic acid or EDTA). For this purpose, we examined samples from a variety of environmental conditions (sludges, mineral soils, organic soils, and soils with particulate and/or soluble contamination). Extraction yields obtained with CaCl(2) (0.01 mol L(-1)) and CH(3)COOH (0.43 mol L(-1)) correlated well with those from the pH(stat) at the same pH (r=0.98 and 0.95, respectively), while the use of EDTA (0.05 mol L(-1)) led to systematically higher extraction yields than those quantified with the pH(stat) at the same pH. However, the pH(stat) test had three distinct advantages: (1) it revealed the relationship between the solubility of the main soil phases and pH; (2) it showed the variation in pollutant leachability due to changes in pH; and (3) it better predicted the maximum contaminant availability. Thus we propose that the pH(stat) is the best laboratory tests to evaluate the contaminant leachability over a wide range of sample types (soil, sludge, and sediment).

  6. Single Particle-Inductively Coupled Plasma Mass Spectroscopy Analysis of Metallic Nanoparticles in Environmental Samples with Large Dissolved Analyte Fractions.

    Science.gov (United States)

    Schwertfeger, D M; Velicogna, Jessica R; Jesmer, Alexander H; Scroggins, Richard P; Princz, Juliska I

    2016-10-18

    There is an increasing interest to use single particle-inductively coupled plasma mass spectroscopy (SP-ICPMS) to help quantify exposure to engineered nanoparticles, and their transformation products, released into the environment. Hindering the use of this analytical technique for environmental samples is the presence of high levels of dissolved analyte which impedes resolution of the particle signal from the dissolved. While sample dilution is often necessary to achieve the low analyte concentrations necessary for SP-ICPMS analysis, and to reduce the occurrence of matrix effects on the analyte signal, it is used here to also reduce the dissolved signal relative to the particulate, while maintaining a matrix chemistry that promotes particle stability. We propose a simple, systematic dilution series approach where by the first dilution is used to quantify the dissolved analyte, the second is used to optimize the particle signal, and the third is used as an analytical quality control. Using simple suspensions of well characterized Au and Ag nanoparticles spiked with the dissolved analyte form, as well as suspensions of complex environmental media (i.e., extracts from soils previously contaminated with engineered silver nanoparticles), we show how this dilution series technique improves resolution of the particle signal which in turn improves the accuracy of particle counts, quantification of particulate mass and determination of particle size. The technique proposed here is meant to offer a systematic and reproducible approach to the SP-ICPMS analysis of environmental samples and improve the quality and consistency of data generated from this relatively new analytical tool.

  7. Pharmacokinetics of tulathromycin in plasma and milk samples after a single subcutaneous injection in lactating goats (Capra hircus).

    Science.gov (United States)

    Grismer, B; Rowe, J D; Carlson, J; Wetzlich, S E; Tell, L A

    2014-04-01

    Eight adult female dairy goats received one subcutaneous administration of tulathromycin at a dosage of 2.5 mg/kg body weight. Blood and milk samples were assayed for tulathromycin and the common fragment of tulathromycin, respectively, using liquid chromatography/mass spectrometry. Pharmacokinetic disposition of tulathromycin was analyzed by a noncompartmental approach. Mean plasma pharmacokinetic parameters (±SD) following single-dose administration of tulathromycin were as follows: C(max) (121.54 ± 19.01 ng/mL); T(max) (12 ± 12-24 h); area under the curve AUC(0→∞) (8324.54 ± 1706.56 ng·h/mL); terminal-phase rate constant λz (0.01 ± 0.002 h⁻¹); and terminal-phase rate constant half-life t1/2λz (67.20 h; harmonic). Mean milk pharmacokinetic parameters (±SD) following 45 days of sampling were as follows: Cmax (1594 ± 379.23 ng/mL); Tmax (12 ± 12-36 h); AUC(0→∞) (72,250.51 ± 18,909.57 ng·h/mL); λz (0.005 ± 0.001 h⁻¹); and t(1/2λz) (155.28 h; harmonic). All goats had injection-site reactions that diminished in size over time. The conclusions from this study were that tulathromycin residues are detectable in milk samples from adult goats for at least 45 days following subcutaneous administration, this therapeutic option should be reserved for cases where other treatment options have failed, and goat milk should be withheld from the human food chain for at least 45 days following tulathromycin administration. © 2013 John Wiley & Sons Ltd.

  8. Quantification and size characterisation of silver nanoparticles in environmental aqueous samples and consumer products by single particle-ICPMS.

    Science.gov (United States)

    Aznar, Ramón; Barahona, Francisco; Geiss, Otmar; Ponti, Jessica; José Luis, Tadeo; Barrero-Moreno, Josefa

    2017-12-01

    Single particle-inductively coupled plasma mass spectrometry (SP-ICPMS) is a promising technique able to generate the number based-particle size distribution (PSD) of nanoparticles (NPs) in aqueous suspensions. However, SP-ICPMS analysis is not consolidated as routine-technique yet and is not typically applied to real test samples with unknown composition. This work presents a methodology to detect, quantify and characterise the number-based PSD of Ag-NPs in different environmental aqueous samples (drinking and lake waters), aqueous samples derived from migration tests and consumer products using SP-ICPMS. The procedure is built from a pragmatic view and involves the analysis of serial dilutions of the original sample until no variation in the measured size values is observed while keeping particle counts proportional to the dilution applied. After evaluation of the analytical figures of merit, the SP-ICPMS method exhibited excellent linearity (r 2 >0.999) in the range (1-25) × 10 4 particlesmL -1 for 30, 50 and 80nm nominal size Ag-NPs standards. The precision in terms of repeatability was studied according to the RSDs of the measured size and particle number concentration values and a t-test (p = 95%) at the two intermediate concentration levels was applied to determine the bias of SP-ICPMS size values compared to reference values. The method showed good repeatability and an overall acceptable bias in the studied concentration range. The experimental minimum detectable size for Ag-NPs ranged between 12 and 15nm. Additionally, results derived from direct SP-ICPMS analysis were compared to the results conducted for fractions collected by asymmetric flow-field flow fractionation and supernatant fractions after centrifugal filtration. The method has been successfully applied to determine the presence of Ag-NPs in: lake water; tap water; tap water filtered by a filter jar; seven different liquid silver-based consumer products; and migration solutions (pure water and

  9. Quantitative analysis of maytansinoid (DM1) in human serum by on-line solid phase extraction coupled with liquid chromatography tandem mass spectrometry - Method validation and its application to clinical samples.

    Science.gov (United States)

    Heudi, Olivier; Barteau, Samuel; Picard, Franck; Kretz, Olivier

    2016-02-20

    A sensitive and specific method was developed and validated for the quantitation of maytansinoid (DM1) in human serum using on-line solid phase extraction (SPE)-liquid chromatography-tandem mass spectrometry (LC-MS/MS). Because DM1 contains a free thiol moiety, likely to readily dimerize or react with other thiol-containing molecules in serum, samples were pre-treated with a reducing agent [tris (2-carboxyethyl) phosphine] (TCEP) and further blocked with N-ethylmaleimide (NEM). The resulting samples were diluted with acetonitrile prior to the on-line solid phase extraction (SPE) on a C18 cartridge. A C18 (150×4.6mm ID 3μm particle size) column was used for chromatographic separation with a 10.0min HPLC gradient and DM1-NEM was detected in the selected reaction monitoring mode of a triple quadrupole mass spectrometer. DM1 concentrations were back-calculated from DM1-NEM amount found in the human serum samples. The quantitation range of the method was 0.200-200ng/mL when using 0.25mL serum. Within-run day precisions (n=6) were 0.9-4.4% and between-run day (3 days runs; n=18) precisions 2.5-5.6%. Method biases were between 3.5-14.5% across the whole calibration range. DM1-NEM exhibited sufficiently stability under all relevant analytical conditions and no DM1 losses from the ADC were observed. Finally, the assay was used for DM1 determination in human serum concentration after the intravenous administration of an investigational antibody drug conjugate (ADC) containing DM1 as payload. Copyright © 2015 Elsevier B.V. All rights reserved.

  10. Association of admission serum calcium levels and in-hospital mortality in patients with acute ST-elevated myocardial infarction: an eight-year, single-center study in China.

    Directory of Open Access Journals (Sweden)

    Xin Lu

    Full Text Available OBJECTIVE: The relationship between admission serum calcium levels and in-hospital mortality in patients with acute ST-segment elevation myocardial infarction (STEMI has not been well definitively explored. The objective was to assess the predictive value of serum calcium levels on in-hospital mortality in STEMI patients. METHODS: From 2003 to 2010, 1431 consecutive STEMI patients admitted to the First Affiliated Hospital of Nanjing Medical University were enrolled in the present study. Patients were stratified according to quartiles of serum calcium from the blood samples collected in the emergency room after admission. Between the aforementioned groups,the baseline characteristics, in-hospital management, and in-hospital mortality were analyzed. The association of serum calcium level with in-hospital mortality was calculated by a multivariable Cox regression analysis. RESULTS: Among 1431 included patients, 79% were male and the median age was 65 years (range, 55-74. Patients in the lower quartiles of serum calcium, as compared to the upper quartiles of serum calcium, were older, had more cardiovascular risk factors, lower rate of emergency revascularization,and higher in-hospital mortality. According to univariate Cox proportional analysis, patients with lower serum calcium level (hazard ratio 0.267, 95% confidence interval 0.164-0.433, p<0.001 was associated with higher in-hospital mortality. The result of multivariable Cox proportional hazard regression analyses showed that the Killip's class≥3 (HR = 2.192, p = 0.026, aspartate aminotransferase (HR = 1.001, p<0.001, neutrophil count (HR = 1.123, p<0.001, serum calcium level (HR = 0.255, p = 0.001, and emergency revascularization (HR = 0.122, p<0.001 were significantly and independently associated with in-hospital mortality in STEMI patients. CONCLUSIONS: Serum calcium was an independent predictor for in-hospital mortality in patients with STEMI. This widely

  11. Quantitative analysis of O-isopropyl methylphosphonic acid in serum samples of Japanese citizens allegedly exposed to sarin: Estimation of internal dosage

    NARCIS (Netherlands)

    Noort, D.; Hulst, A.G.; Platenburg, D.H.J.M.; Polhuijs, M.; Benschop, H.P.

    1998-01-01

    A convenient and rapid micro-anion exchange liquid chromatography (LC) tandem electrospray mass spectrometry (MS) procedure was developed for quantitative analysis in serum of O-isopropyl methylphosphonic acid (IMPA), the hydrolysis product of the nerve agent sarin. The mass spectrometric procedure

  12. On-line coupling of solid-phase extraction with mass spectrometry for the analysis of biological samples III. Determination of prednisolone in serum

    NARCIS (Netherlands)

    van Hout, M.W.J.; Hofland, C.M; Niederlander, H.A G; Bruins, A.P.; de Zeeuw, R.A.; de Jong, G.J.

    2003-01-01

    Solid-phase extraction (SPE) was directly coupled to mass spectrometry (MS) to assess the feasibility of the system for the rapid determination of prednisolone in serum. A C-18 stationary phase allowed washing of the cartridge with 25% methanol. Elution was performed by switching the methanol

  13. Sample preparation of human serum for the analysis of tumor markers : Comparison of different approaches for albumin and gamma-globulin depletion

    NARCIS (Netherlands)

    Govorukhina, N I; Keizer-Gunnink, A; van der Zee, A G J; de Jong, Steven; de Bruijn, H W A; Bischoff, R

    2003-01-01

    LC-MS is a powerful method for the sensitive detection of proteins and peptides in biological fluids. However, the presence of highly abundant proteins often masks those of lower abundance and thus generally prevents their detection and identification in proteomic studies. In human serum the most

  14. Does Vitamin D Sufficiency Equate to a Single Serum 25-Hydroxyvitamin D Level or Are Different Levels Required for Non-Skeletal Diseases?

    Directory of Open Access Journals (Sweden)

    Simon Spedding

    2013-12-01

    Full Text Available Objective: Clarify the concept of vitamin D sufficiency, the relationship between efficacy and vitamin D status and the role of Vitamin D supplementation in the management of non-skeletal diseases. We outline reasons for anticipating different serum vitamin D levels are required for different diseases. Method: Review the literature for evidence of efficacy of supplementation and minimum effective 25-hydroxyvitamin D (25-OHD levels in non-skeletal disease. Results: Evidence of efficacy of vitamin supplementation is graded according to levels of evidence. Minimum effective serum 25-OHD levels are lower for skeletal disease, e.g., rickets (25 nmol/L, osteoporosis and fractures (50 nmol/L, than for premature mortality (75 nmol/L or non-skeletal diseases, e.g., depression (75 nmol/L, diabetes and cardiovascular disease (80 nmol/L, falls and respiratory infections (95 nmol/L and cancer (100 nmol/L. Conclusions: Evidence for the efficacy of vitamin D supplementation at serum 25-OHD levels ranging from 25 to 100 nmol/L has been obtained from trials with vitamin D interventions that change vitamin D status by increasing serum 25-OHD to a level consistent with sufficiency for that disease. This evidence supports the hypothesis that just as vitamin D metabolism is tissue dependent, so the serum levels of 25-OHD signifying deficiency or sufficiency are disease dependent.

  15. A safety assessment of rotary mode core sampling in flammable gas single shell tanks: Hanford Site, Richland, Washington

    Energy Technology Data Exchange (ETDEWEB)

    Raymond, R.E.

    1996-04-15

    This safety assessment (SA) addresses each of the required elements associated with the installation, operation, and removal of a rotary-mode core sampling (RMCS) device in flammable-gas single-shell tanks (SSTs). The RMCS operations are needed in order to retrieve waste samples from SSTs with hard layers of waste for which push-mode sampling is not adequate for sampling. In this SA, potential hazards associated with the proposed action were identified and evaluated systematically. Several potential accident cases that could result in radiological or toxicological gas releases were identified and analyzed and their consequences assessed. Administrative controls, procedures and design changes required to eliminate or reduce the potential of hazards were identified. The accidents were analyzed under nine categories, four of which were burn scenarios. In SSTS, burn accidents result in unacceptable consequences because of a potential dome collapse. The accidents in which an aboveground burn propagates into the dome space were shown to be in the ``beyond extremely unlikely`` frequency category. Given the unknown nature of the gas-release behavior in the SSTS, a number of design changes and administrative controls were implemented to achieve these low frequencies. Likewise, drill string fires and dome space fires were shown to be very low frequency accidents by taking credit for the design changes, controls, and available experimental and analytical data. However, a number of Bureau of Mines (BOM) tests must be completed before some of the burn accidents can be dismissed with high confidence. Under the category of waste fires, the possibility of igniting the entrapped gases and the waste itself were analyzed. Experiments are being conducted at the BOM to demonstrate that the drill bit is not capable of igniting the trapped gas in the waste. Laboratory testing and thermal analysis demonstrated that, under normal operating conditions, the drill bit will not create high

  16. A safety assessment of rotary mode core sampling in flammable gas single shell tanks: Hanford Site, Richland, Washington

    International Nuclear Information System (INIS)

    Raymond, R.E.

    1996-01-01

    This safety assessment (SA) addresses each of the required elements associated with the installation, operation, and removal of a rotary-mode core sampling (RMCS) device in flammable-gas single-shell tanks (SSTs). The RMCS operations are needed in order to retrieve waste samples from SSTs with hard layers of waste for which push-mode sampling is not adequate for sampling. In this SA, potential hazards associated with the proposed action were identified and evaluated systematically. Several potential accident cases that could result in radiological or toxicological gas releases were identified and analyzed and their consequences assessed. Administrative controls, procedures and design changes required to eliminate or reduce the potential of hazards were identified. The accidents were analyzed under nine categories, four of which were burn scenarios. In SSTS, burn accidents result in unacceptable consequences because of a potential dome collapse. The accidents in which an aboveground burn propagates into the dome space were shown to be in the ''beyond extremely unlikely'' frequency category. Given the unknown nature of the gas-release behavior in the SSTS, a number of design changes and administrative controls were implemented to achieve these low frequencies. Likewise, drill string fires and dome space fires were shown to be very low frequency accidents by taking credit for the design changes, controls, and available experimental and analytical data. However, a number of Bureau of Mines (BOM) tests must be completed before some of the burn accidents can be dismissed with high confidence. Under the category of waste fires, the possibility of igniting the entrapped gases and the waste itself were analyzed. Experiments are being conducted at the BOM to demonstrate that the drill bit is not capable of igniting the trapped gas in the waste. Laboratory testing and thermal analysis demonstrated that, under normal operating conditions, the drill bit will not create high

  17. Method validation for preparing serum and plasma samples from human blood for downstream proteomic, metabolomic, and circulating nucleic acid-based applications.

    Science.gov (United States)

    Ammerlaan, Wim; Trezzi, Jean-Pierre; Lescuyer, Pierre; Mathay, Conny; Hiller, Karsten; Betsou, Fay

    2014-08-01

    Formal method validation for biospecimen processing in the context of accreditation in laboratories and biobanks is lacking. Serum and plasma processing protocols were validated for fitness-for-purpose in terms of key downstream endpoints, and this article demonstrates methodology for biospecimen processing method validation. Serum and plasma preparation from human blood was optimized for centrifugation conditions with respect to microparticle counts. Optimal protocols were validated for methodology and reproducibility in terms of acceptance criteria based on microparticle counts, DNA and hemoglobin concentration, and metabolomic and proteomic profiles. These parameters were also used to evaluate robustness for centrifugation temperature (4°C versus room temperature [RT]), deceleration (low, medium, high) and blood stability (after a 2-hour delay). Optimal protocols were 10-min centrifugation for serum and 20-min for plasma at 2000 g, medium brake, RT. Methodology and reproducibility acceptance criteria were met for both protocols except for reproducibility of plasma metabolomics. Overall, neither protocol was robust for centrifugation at 4°C versus RT. RT gave higher microparticles and free DNA yields in serum, and fewer microparticles with less hemolysis in plasma. Overall, both protocols were robust for fast, medium, and low deceleration, with a medium brake considered optimal. Pre-centrifugation stability after a 2-hour delay was seen at both temperatures for hemoglobin concentration and proteomics, but not for microparticle counts. We validated serum and plasma collection methods suitable for downstream protein, metabolite, or free nucleic acid-based applications. Temperature and pre-centrifugation delay can influence analytic results, and laboratories and biobanks should systematically record these conditions in the scope of accreditation.

  18. Glaucoma and vitamins A, C, and E supplement intake and serum levels in a population-based sample of the United States.

    Science.gov (United States)

    Wang, S Y; Singh, K; Lin, S C

    2013-04-01

    To investigate the potential association between glaucoma prevalence and supplemental intake, as well as serum levels of vitamins A, C and E. This cross-sectional study included 2912 participants in the 2005-2006 National Health and Nutrition Examination Survey, age ≥40 years, who self-reported a presence or absence of glaucoma. Participants were interviewed regarding the use of dietary supplements during the preceding 30-day period. Participants also underwent serum measurements of vitamins A, C, and E (both alpha- and gamma-tocopherol). Information on the primary outcome measure, presence or absence of glaucoma, as well as demographic information, comorbidities and health-related behaviors, was assessed via interview. Multivariate odds ratios for self-reported glaucoma, comparing the highest quartile of consumption to no consumption, and adjusted for potential confounding variables were 0.48 (95% confidence interval (CI) 0.13-1.82) for vitamin A, 0.47 (95% CI 0.23-0.97) for vitamin C, and 2.59 (95% CI 0.89-7.56) for vitamin E. Adjusted odds ratios for self-reported glaucoma comparing the highest vs lowest quintiles of vitamin serum levels were 1.44 (95% CI 0.79-2.62) for vitamin A, 0.94 (95% CI 0.42-2.11) for vitamin C, 1.40 (95% CI 0.70-2.81) for alpha-tocopherol, and 0.64 (95% CI 0.24-1.70) for gamma-tocopherol. Neither supplementary consumption with nor serum levels of vitamins A and E were found to be associated with glaucoma prevalence. While low- and high-dose supplementary consumption of vitamin C was found to be associated with decreased odds of glaucoma, serum levels of vitamin C did not correlate with glaucoma prevalence.

  19. [The National Serum Bank].

    Science.gov (United States)

    Magos-López, C; Sánchez-Villarreal, F; Gutiérrez, G; Tapia-Conyer, R

    1992-01-01

    A National Serum Bank was established to store sera obtained during the National Seroepidemiological Survey performed in Mexico in 1987. More than 70,000 serum samples were obtained from subjects of either sex 1-99 years of age in each of the 32 states of the country. The current collection of sera includes 28,704 male samples and 40,629 female samples. This paper describes the procedures for handling serum samples, including reception registry, storage and distribution to several laboratories for detection of measles, rubella, poliomyelitis, AIDS, diphtheria, pertussis, tetanus, brucella, salmonella, amoeba, toxoplasma, American trypanosomiasis and cysticercus. Determinations of total cholesterol were also made in order to describe its distribution and to identify the prevalence of hypercholesterolemia.

  20. Searching for stable Na-ordered phases in single-crystal samples of γ-NaxCoO2

    Science.gov (United States)

    Shu, G. J.; Prodi, Andrea; Chu, S. Y.; Lee, Y. S.; Sheu, H. S.; Chou, F. C.

    2007-11-01

    We report on the preparation and characterization of single-crystal γ phase NaxCoO2 with 0.25≤x≤0.84 using a nonaqueous electrochemical chronoamperemetry technique. By carefully mapping the overpotential versus x (for xfind six distinct stable phases with Na levels corresponding to xtilde 0.75, 0.71, 0.50, 0.43, 0.33, and 0.25. The composition with x≃0.55 appears to have a critical Na concentration which separates samples with different magnetic behavior as well as different Na ion diffusion mechanisms. Chemical analysis of an aged crystal reveals different Na ion diffusion mechanisms above and below xc˜0.53 , where the diffusion process above xc has a diffusion coefficient about five times larger than that below xc . The series of crystals were studied with x-ray diffraction, susceptibility, and transport measurements. The crystal with x=0.5 shows a weak ferromagnetic transition below T=27K in addition to the usual transitions at T=51 and 88K . The resistivity of the Curie-Weiss metallic Na0.71CoO2 composition has a very low residual resistivity, which attests to the high homogeneity of the crystals prepared by this improved electrochemical method. Our results on the various stable crystal compositions point to the importance of Na ion ordering across the phase diagram.

  1. A device for the application of uniaxial strain to single crystal samples for use in synchrotron radiation experiments

    Energy Technology Data Exchange (ETDEWEB)

    Gannon, L. [Clarendon Laboratory, University of Oxford Physics Department, Parks Road, Oxford OX1 3PU (United Kingdom); Diamond Light Source, Harwell Science and Innovation Campus, Didcot OX11 ODE (United Kingdom); Bosak, A. [European Synchrotron Radiation Facility, BP 220, F-38043 Grenoble Cedex (France); Burkovsky, R. G. [European Synchrotron Radiation Facility, BP 220, F-38043 Grenoble Cedex (France); Peter the Great Saint-Petersburg Polytechnic University, 29 Politekhnicheskaya, 195251, St.-Petersburg (Russian Federation); Nisbet, G.; Hoesch, M., E-mail: Moritz.Hoesch@diamond.ac.uk [Diamond Light Source, Harwell Science and Innovation Campus, Didcot OX11 ODE (United Kingdom); Petrović, A. P. [DPMC-MaNEP, Université de Genève, Quai Ernest-Ansermet 24, 1211 Genève 4 (Switzerland)

    2015-10-15

    We present the design, construction, and testing of a straining device compatible with many different synchrotron radiation techniques, in a wide range of experimental environments (including low temperature, high field and ultra-high vacuum). The device has been tested by X-ray diffraction on single crystal samples of quasi-one-dimensional Cs{sub 2}Mo{sub 6}Se{sub 6} and K{sub 2}Mo{sub 6}Se{sub 6}, in which microscopic strains up to a Δc/c = 0.12% ± 0.01% change in the c lattice parameters have been achieved. We have also used the device in an inelastic X-ray scattering experiment, to probe the strain-dependent speed of sound ν along the c axis. A reduction Δν/ν of up to −3.8% was obtained at a strain of Δc/c = 0.25% in K{sub 2}Mo{sub 6}Se{sub 6}.

  2. A disposable screen-printed silver strip sensor for single drop analysis of halide in biological samples.

    Science.gov (United States)

    Chiu, Mei-Hsin; Cheng, Wan-Ling; Muthuraman, Govindan; Hsu, Cheng-Teng; Chung, Hsieh-Hsun; Zen, Jyh-Myng

    2009-06-15

    A screen-printed silver strip with three-electrode configuration of Ag-working, Ag-counter and Ag/Ag(x)O reference electrodes was developed for simultaneous determination of chloride, bromide and iodide in aqueous solutions. It was fabricated simply by screen-printing silver ink onto a polypropylene (PP) base. The in-situ prepared Ag/Ag(x)O reference electrode can avoid the leaching interference in chloride detection while using a conventional Ag/AgCl reference electrode. A single drop of analyte (50 microl) is enough to determine iodide, bromide and chloride by measuring the well-separated oxidation peak currents of respective silver halides. The calibration graph was linear from 10 microM to 20 mM for iodide and bromide and 100 microM to 20 mM for chloride and the detection limit (S/N=3) was 3.05 microM, 2.95 microM and 18.83 microM for iodide, bromide and chloride, respectively. The strip is designed to be disposable and as such manual polishing is not necessary. The proposed sensor is not only simple to manufacture and easy to operate but also fast and precise with little detection volume. It is successfully applied to the determination of halide ions in real samples.

  3. Analysis of the Cross-Reactivity of Various 56 kDa Recombinant Protein Antigens with Serum Samples Collected after Orientia tsutsugamushi Infection by ELISA

    Science.gov (United States)

    2011-01-01

    terized by fever, rash, eschar, pneumonitis, meningitis, and in some cases, disseminated intravascular coagulation that may lead to circulatory...addition, another gel was run and transferred onto nitrocellulose membrane. The membrane was blocked with 10% milk in Tris-buffered saline (TBS)–Tween20...mouse serum in TBST containing 5% milk for one hour at room temperature. The membrane was washed three times (five minutes/wash) and incubated with

  4. Are serum adiponectin concentrations in a population sample of 64-year-old Caucasian women with varying glucose tolerance associated with ultrasound-assessed atherosclerosis?

    Science.gov (United States)

    Behre, C J; Brohall, G; Hulthe, J; Wikstrand, J; Fagerberg, B

    2006-09-01

    To examine whether serum adiponectin concentrations were associated with subclinical atherosclerosis assessed as intima media thickness (IMT) in the carotid arteries in Caucasian women with varying degrees of glucose tolerance. From a population-based cohort of 64-year-old Swedish women, 533 subjects with type 2 diabetes (DM2, n=177), impaired glucose tolerance (IGT; n=178) or normal glucose tolerance (NGT, n=178) were recruited. Anthropometrics, usual cardiovascular risk factors were examined and ultrasound examination of the carotid arteries was performed. Women with low adiponectin concentrations were characterized by thick IMT, higher prevalence of DM2, history of previous myocardial infarction, angina pectoris, anti-hypertensive treatment and high body mass index (BMI), waist circumference, plasma insulin, serum triglycerides, fasting glucose, HbA1c, and low serum HDL cholesterol levels. Carotid IMT correlated with HbA1c (r=0.24, PDM2 (r=0.16, P<0.001), systolic blood pressure (r=0.16, P<0.001), blood glucose (r=0.16, P<0.001), triglycerides (r=0.15, P<0.001), and reversely to adiponectin (r=-0.11, P=0.01), HDL cholesterol (r=-0.13, P=0.004), and alcohol intake (r=-0.087, P<0.05). A more detailed analysis of underlying associations was difficult due to a high co-linearity between these variable. Low serum adiponectin concentrations were associated with increased carotid artery IMT, and several risk factors for cardiovascular diseases, mainly those constituting the metabolic syndrome.

  5. Detection of cryoglobulins in serum of Caspian miniature horse

    Directory of Open Access Journals (Sweden)

    Atyabi, N,

    2012-06-01

    Full Text Available Blood samples were collected from 20 healthy miniature Caspian horses at 37 °C. Isolation of cryoglobulin was performed based on a standard method in present study. Harvested sera were kept at 4 °C for two hours and then examined for cryoglubolin. Four serum samples containing precipitate Suspicious of containing cryoglobulin were selected. Subsequently serum protein electrophoresis was performed on normal serum samples and also on four serum samples containing precipitates using an automated electrophoresis system on cellulose acetate strips. In addition Ig isotypes detection (IgG, IgM and IgA was performed on both precipitates and serum containing precipitates using single radio immunediffusion method (SRID. A narrow-based peak on gamma region of precipitate acetate cellulose strips was observed. Precipitate concentrations were strikingly higher than normal concentration of serum immuneglobulins. It can be suggested that cryoglobulin concentration in a proportion of Caspian miniature horse is higher than other equides may be in relation with animal susceptibility to neoplasias such as lymphoma and leukemia.

  6. Quantification of PCDD/Fs and dioxin-like PCBs in small amounts of human serum using the sensitive H1L7.5c1 mouse hepatoma cell line: optimization and analysis of human serum samples from adolescents of the Flemish human biomonitoring program FLEHS II

    Science.gov (United States)

    Croes, K.; Van Langenhove, K.; Den Hond, E.; Bruckers, L.; Colles, A.; Koppen, G.; Loots, I.; Nelen, V.; Schoeters, G.; Nawrot, T.; Van Larebeke, N.; Denison, M.S.; Vandermarken, T.; Elskens, M.; Baeyens, W.

    2012-01-01

    Since the CALUX (Chemically Activated LUciferase gene eXpression) bioassay is a fast and inexpensive tool for the throughput analysis of dioxin-like compounds in a large number of samples and requires only small sample volumes, the use of this technique in human biomonitoring programs provides a good alternative to GC-HRMS. In this study, a method for the separate analysis of PCDD/Fs and dioxin-like PCBs (dl-PCBs) in human serum with the new sensitive H1L7.5c1 mouse hepatoma cell line was optimized. Sample dilution factors of 5 and 2.4 were selected for routine analysis of respectively the PCDD/Fs and dl-PCBs. The validation studies showed that repeatability and within-lab reproducibility for the QC standard were within the in-house criteria. A long-term within-lab reproducibility of 25% for the PCDD/F fraction and 41% for the dl-PCB fraction for the analysis of pooled serum samples, expressed as pg BEQ/g fat, was determined. CALUX recoveries of the spiked procedural blanks were within the acceptable in-house limits of 80–120% for both fractions and the LOQ was 30.3 pg BEQ/g fat for the PCDD/Fs and 14.5 pg BEQ/g fat for the dl-PCBs. The GC-HRMS recovery of a C13-spiked pooled serum sample was between 60–90 % for all PCDD/F congeners and between 67–82 % for the non-ortho PCBs. An adequate separation between both fractions was found. The CALUX/GC-HRMS ratio for a pooled serum sample was respectively 2.0 and 1.4 for the PCDD/Fs and the dl-PCBs, indicating the presence of additional AhR active compounds. As expected, a correlation was found between human serum samples analyzed with both the new H1L7.5c1 cell line and the more established H1L6.1c3 cell line. The geometric mean CALUX-BEQ values, reported for the adolescents of the second Flemish Environment and Health Study (FLEHS II) recruited in 2009–2010, were 108 (95% CI: 101–114) pg CALUX-BEQ/g fat for the PCDD/Fs and 32.1 (30.1–34.2) pg CALUX-BEQ/g fat for the dioxin-like PCBs. PMID:21962672

  7. The concentrations of clinafloxacin in alveolar macrophages, epithelial lining fluid, bronchial mucosa and serum after administration of single 200 mg oral doses to patients undergoing fibre-optic bronchoscopy.

    Science.gov (United States)

    Honeybourne, D; Andrews, J M; Cunningham, B; Jevons, G; Wise, R

    1999-01-01

    The concentrations of clinafloxacin were measured in serum, bronchial mucosa, alveolar macrophages and epithelial lining fluid after single 200 mg oral doses of clinafloxacin had been administered to 15 subjects who were undergoing bronchoscopy. Concentrations were measured using a microbiological assay method. Mean concentrations in serum, bronchial mucosa, alveolar macrophages and epithelial lining fluid at a mean of 1.27 h post-dose were 1.54, 2.65, 15.60 and 2.71 mg/L respectively. These site concentrations exceeded the MIC90 for common respiratory pathogens and indicate that clinafloxacin is likely to be effective in the treatment of a wide range of respiratory tract infections.

  8. Measuring word complexity in speech screening: single-word sampling to identify phonological delay/disorder in preschool children.

    Science.gov (United States)

    Anderson, Carolyn; Cohen, Wendy

    2012-01-01

    Children's speech sound development is assessed by comparing speech production with the typical development of speech sounds based on a child's age and developmental profile. One widely used method of sampling is to elicit a single-word sample along with connected speech. Words produced spontaneously rather than imitated may give a more accurate indication of a child's speech development. A published word complexity measure can be used to score later-developing speech sounds and more complex word patterns. There is a need for a screening word list that is quick to administer and reliably differentiates children with typically developing speech from children with patterns of delayed/disordered speech. To identify a short word list based on word complexity that could be spontaneously named by most typically developing children aged 3;00-5;05 years. One hundred and five children aged between 3;00 and 5;05 years from three local authority nursery schools took part in the study. Items from a published speech assessment were modified and extended to include a range of phonemic targets in different word positions in 78 monosyllabic and polysyllabic words. The 78 words were ranked both by phonemic/phonetic complexity as measured by word complexity and by ease of spontaneous production. The ten most complex words (hereafter Triage 10) were named spontaneously by more than 90% of the children. There was no significant difference between the complexity measures for five identified age groups when the data were examined in 6-month groups. A qualitative analysis revealed eight children with profiles of phonological delay or disorder. When these children were considered separately, there was a statistically significant difference (p speech from those with delayed or disordered speech patterns. The Triage 10 words can be used as a screening tool for triage and general assessment and have the potential to monitor progress during intervention. Further testing is being undertaken to

  9. A generic-tee-plenum mixing system for application to single point aerosol sampling in stacks and ducts.

    Science.gov (United States)

    Han, Taewon; O'Neal, Dennis L; Ortiz, Carlos A

    2007-01-01

    The ANSI/HPS-N13.1-1999 standard is based on the concept of obtaining a single point representative sample from a location where the velocity and contaminant profiles are relatively uniform. It is difficult to predict the level of mixing in an arbitrary stack or duct without experimental data to meet the ANSI/HPS N13.1-1999 requirements. The goal of this study was to develop experimental data for a range of conditions in "S" (S-shaped configuration) duct systems with different mixing elements and "S" systems having one or two mixing elements. Results were presented in terms of the coefficients of variation (COVs) for velocity, tracer gas, and 10-mum aerodynamic diameter (AD) aerosol particle profiles at different downstream locations for each mixing element. Five mixing elements were tested, including a 90 degrees elbow, a commercial static mixer, a Small-Horizontal Generic-Tee-Plenum (SH-GTP), a Small-Vertical Generic-Tee-Plenum (SV-GTP), and a Large-Horizontal Generic-Tee-Plenum (LH-GTP) system. The COVs for velocity, gas concentration, and aerosol particles for the three GTP systems were all determined to be less than 8%. Tests with two different sizes of GTPs were conducted, and the results showed the performance of the GTPs was relatively unaffected by either size or velocity as reflected by the Reynolds number. The pressure coefficients were 0.59, 0.57, and 0.65, respectively, for the SH-GTP, SV-GTP, and LH-GTP. The pressure drop for the GTPs was approximately twice that of the round elbow, but a factor of 5 less than a Type IV Air Blender. The GTP was developed to provide a sampling location less than 4-duct diameters downstream of a mixing element with low pressure drop condition. The object of the developmental effort was to provide a system that could be employed in new stack; however, the concept of GTPs could also be retrofitted onto existing system applications as well. Results from these tests show that the system performance is well within the ANSI

  10. Feasibility study of a single-shot 3D electron bunch shape monitor with an electro-optic sampling technique

    Directory of Open Access Journals (Sweden)

    Yuichi Okayasu

    2013-05-01

    Full Text Available We developed a three-dimensional electron bunch charge distribution (3D-BCD monitor with single-shot detection, and a spectral decoding based electro-optic (EO sampling technique for a nondestructive monitor enables real-time reconstruction of the three-dimensional distribution of a bunch charge. We realized three goals by simultaneously probing a number of Pockels EO crystals that surround the electron beam axis with hollow and radial polarized laser pulses. First, we performed a feasibility test as a simple case of a 3D-BCD monitor probing two ZnTe crystals as EO detectors installed on the opposite angle to the electron beam axis and confirmed that we simultaneously obtained both EO signals. Since the adopted hollow probe laser pulse is not only radially polarized but also temporally shifted azimuthally, some disorders in the radial polarization distribution of such a laser pulse were numerically analyzed with a plane-wave expansion method. Based on the above investigations, the 3D-BCD monitor is feasible both in experimental and numerical estimations. Furthermore, we previously developed a femtosecond response organic crystal as a Pockels EO detector and a broadband probe laser (≥350  nm in FWHM; the 3D-BCD monitor realizes 30- to 40-fs (FWHM temporal resolution. Eventually, the monitor is expected to be equipped in such advanced accelerators as XFEL to measure and adjust the electron bunch charge distribution in real time. The 3D-BCD measurement works as a critical tool to provide feedback to seeded FELs.

  11. On the preparation of as-produced and purified single-walled carbon nanotube samples for standardized X-ray diffraction characterization

    International Nuclear Information System (INIS)

    Allaf, Rula M.; Rivero, Iris V.; Spearman, Shayla S.; Hope-Weeks, Louisa J.

    2011-01-01

    The aim of this research was to specify proper sample conditioning for acquiring representative X-ray diffraction (XRD) profiles for single-walled carbon nanotube (SWCNT) samples. In doing so, a specimen preparation method for quantitative XRD characterization of as-produced and purified arc-discharge SWCNT samples has been identified. Series of powder XRD profiles were collected at different temperatures, states, and points of time to establish appropriate conditions for acquiring XRD profiles without inducing much change to the specimen. It was concluded that heating in the 300-450 deg. C range for 20 minutes, preferably vacuum-assisted, and then sealing the sample is an appropriate XRD specimen preparation technique for purified arc-discharge SWCNT samples, while raw samples do not require preconditioning for characterization. - Graphical Abstract: A sample preparation method for XRD characterization of as-produced and purified arc-discharge SWCNT samples is identified. The preparation technique seeks to acquire representative XRD profiles without inducing changes to the samples. Purified samples required 20 minutes of heating at (300-450)deg. C, while raw samples did not require preconditioning for characterization. Highlights: → Purification routines may induce adsorption onto the SWCNT samples. → Heating a SWCNT sample may result in material loss, desorption, and SWCNTs closing. → Raw arc-discharge samples do not require preparation for XRD characterization. → Heating is appropriate specimen preparation for purified and heat-treated samples. → XRD data fitting is required for structural analysis of SWCNT bundles.

  12. Determination of the technetium-99m mercaptoacetyltriglycine plasma clearance in children by means of a single blood sample: a multicentre study

    International Nuclear Information System (INIS)

    Piepsz, A.; Gordon, I.; Hahn, K.; Kolinska, J.; Kotzerke, J.; Sixt, R.

    1993-01-01

    A multicentree European study was undertaken in order to determine a reasonable algorithm allowing the determination of overall technetium-99m mercaptoacetyltriglycine clearance using a single blood sample. Employing multiple blood sample clearance as a reference method, it was shown that an acceptable estimation of the MAG3 renal clearance could be obtained using a blood sample taken at any time between 30 and 40 min after tracer injection. After correction for body surface area comparison of clearance determined using (a) the single blood sample and (b) the multiple blood samples provided a coefficient of correlation of 0.949 and an SEE of 27 ml/min. This algorithm is valid for clearance values higher than 100 ml/min/1.73 m 2 and for children older than 1 year of age. (orig.)

  13. Single Nucleotide Polymorphisms in the FADS Gene Cluster but not the ELOVL2 Gene are Associated with Serum Polyunsaturated Fatty Acid Composition and Development of Allergy (in a Swedish Birth Cohort

    Directory of Open Access Journals (Sweden)

    Malin Barman

    2015-12-01

    Full Text Available Exposure to polyunsaturated fatty acids (PUFA influences immune function and may affect the risk of allergy development. Long chain PUFAs are produced from dietary precursors catalyzed by desaturases and elongases encoded by FADS and ELOVL genes. In 211 subjects, we investigated whether polymorphisms in the FADS gene cluster and the ELOVL2 gene were associated with allergy or PUFA composition in serum phospholipids in a Swedish birth-cohort sampled at birth and at 13 years of age; allergy was diagnosed at 13 years of age. Minor allele carriers of rs102275 and rs174448 (FADS gene cluster had decreased proportions of 20:4 n-6 in cord and adolescent serum and increased proportions of 20:3 n-6 in cord serum as well as a nominally reduced risk of developing atopic eczema, but not respiratory allergy, at 13 years of age. Minor allele carriers of rs17606561 in the ELOVL2 gene had nominally decreased proportions of 20:4 n-6 in cord serum but ELOVL polymorphisms (rs2236212 and rs17606561 were not associated with allergy development. Thus, reduced capacity to desaturase n-6 PUFAs due to FADS polymorphisms was nominally associated with reduced risk for eczema development, which could indicate a pathogenic role for long-chain PUFAs in allergy development.

  14. Single Nucleotide Polymorphisms in the FADS Gene Cluster but not the ELOVL2 Gene are Associated with Serum Polyunsaturated Fatty Acid Composition and Development of Allergy (in a Swedish Birth Cohort).

    Science.gov (United States)

    Barman, Malin; Nilsson, Staffan; Torinsson Naluai, Åsa; Sandin, Anna; Wold, Agnes E; Sandberg, Ann-Sofie

    2015-12-03

    Exposure to polyunsaturated fatty acids (PUFA) influences immune function and may affect the risk of allergy development. Long chain PUFAs are produced from dietary precursors catalyzed by desaturases and elongases encoded by FADS and ELOVL genes. In 211 subjects, we investigated whether polymorphisms in the FADS gene cluster and the ELOVL2 gene were associated with allergy or PUFA composition in serum phospholipids in a Swedish birth-cohort sampled at birth and at 13 years of age; allergy was diagnosed at 13 years of age. Minor allele carriers of rs102275 and rs174448 (FADS gene cluster) had decreased proportions of 20:4 n-6 in cord and adolescent serum and increased proportions of 20:3 n-6 in cord serum as well as a nominally reduced risk of developing atopic eczema, but not respiratory allergy, at 13 years of age. Minor allele carriers of rs17606561 in the ELOVL2 gene had nominally decreased proportions of 20:4 n-6 in cord serum but ELOVL polymorphisms (rs2236212 and rs17606561) were not associated with allergy development. Thus, reduced capacity to desaturase n-6 PUFAs due to FADS polymorphisms was nominally associated with reduced risk for eczema development, which could indicate a pathogenic role for long-chain PUFAs in allergy development.

  15. Serum sickness

    Science.gov (United States)

    ... the problem should be stopped. Avoid using that medicine or antiserum in the future. ... Call your provider if you received medicine or antiserum in the last 4 weeks and have symptoms of serum sickness.

  16. Sample Preparation Methods Following CellSearch Approach Compatible of Single-Cell Whole-Genome Amplification: An Overview

    NARCIS (Netherlands)

    Swennenhuis, Joost Franciscus; Terstappen, Leonardus Wendelinus Mathias Marie; Kroneis, Thomas

    2015-01-01

    Single cells are increasingly used to determine the heterogeneity of therapy targets in the genome during the course of a disease. The first challenge using single cells is to isolate these cells from the surrounding cells, especially when the targeted cells are rare. A number of techniques have

  17. Testing single-grain quartz OSL methods using sediment samples with independent age control from the Bordes-Fitte rockshelter (Roches d'Abilly site, Central France)

    DEFF Research Database (Denmark)

    Thomsen, Kristina Jørkov; Murray, Andrew Sean; Buylaert, Jan-Pieter

    2016-01-01

    We present quartz single-grain dose distributions for four well-bleached and unmixed sediment samples with independent age control (22–48 ka), from the archaeologically important Bordes-Fitte rockshelter at Roches d'Abilly, France. This site has previously been dated using 14C AMS dating and stan......We present quartz single-grain dose distributions for four well-bleached and unmixed sediment samples with independent age control (22–48 ka), from the archaeologically important Bordes-Fitte rockshelter at Roches d'Abilly, France. This site has previously been dated using 14C AMS dating...

  18. Methyl-binding domain protein-based DNA isolation from human blood serum combines DNA analyses and serum-autoantibody testing

    Directory of Open Access Journals (Sweden)

    Jungbauer Christof

    2011-09-01

    Full Text Available Abstract Background Circulating cell free DNA in serum as well as serum-autoantibodies and the serum proteome have great potential to contribute to early cancer diagnostics via non invasive blood tests. However, most DNA preparation protocols destroy the protein fraction and therefore do not allow subsequent protein analyses. In this study a novel approach based on methyl binding domain protein (MBD is described to overcome the technical difficulties of combining DNA and protein analysis out of one single serum sample. Methods Serum or plasma samples from 98 control individuals and 54 breast cancer patients were evaluated upon silica membrane- or MBD affinity-based DNA isolation via qPCR targeting potential DNA methylation markers as well as by protein-microarrays for tumor-autoantibody testing. Results In control individuals, an average DNA level of 22.8 ± 25.7 ng/ml was detected applying the silica membrane based protocol and 8.5 ± 7.5 ng/ml using the MBD-approach, both values strongly dependent on the serum sample preparation methods used. In contrast to malignant and benign tumor serum samples, cell free DNA concentrations were significantly elevated in sera of metastasizing breast cancer patients. Technical evaluation revealed that serum upon MBD-based DNA isolation is suitable for protein-array analyses when data are consistent to untreated serum samples. Conclusion MBD affinity purification allows DNA isolations under native conditions retaining the protein function, thus for example enabling combined analyses of DNA methylation and autoantigene-profiles from the same serum sample and thereby improving minimal invasive diagnostics.

  19. Effect of single-layer centrifugation or washing on frozen-thawed donkey semen quality: Do they have the same effect regardless of the quality of the sample?

    Science.gov (United States)

    Ortiz, I; Dorado, J; Morrell, J M; Crespo, F; Gosálvez, J; Gálvez, M J; Acha, D; Hidalgo, M

    2015-07-15

    The aims of this study were to determine the sperm quality of frozen-thawed donkey sperm samples after single-layer centrifugation (SLC) using Androcoll-E in comparison to sperm washing or no centrifugation and to determine if the effect on the sperm quality after SLC or sperm washing depends on the quality of the sample. Frozen-thawed sperm samples from Andalusian donkeys were divided into three aliquots, and they were processed using three different techniques after thawing: uncentrifuged diluted control (UDC), sperm washing (SW), and SLC. Afterward, sperm quality index was estimated by integrating all parameters (total and progressive sperm motility, membrane integrity, and DNA fragmentation) in a single value. The relationship between the sperm quality of thawed UDC samples and the effect on sperm parameters in SW and SLC-selected samples was assessed. Sperm quality index was significantly higher (P < 0.001) in SLC (0.8 ± 0.0) samples than that in UDC (0.6 ± 0.0) and SW (0.6 ± 0.0) samples, regardless of the sperm quality index after thawing of the sperm sample. In conclusion, SLC of frozen-thawed donkey spermatozoa using Androcoll-E-Small can be a suitable procedure for selecting frozen-thawed donkey sperm with better quality, in particular in those samples where an improvement in motility is needed. Copyright © 2015 Elsevier Inc. All rights reserved.

  20. Preparation and Loading Process of Single Crystalline Samples into a Gas Environmental Cell Holder for In Situ Atomic Resolution Scanning Transmission Electron Microscopic Observation.

    Science.gov (United States)

    Straubinger, Rainer; Beyer, Andreas; Volz, Kerstin

    2016-06-01

    A reproducible way to transfer a single crystalline sample into a gas environmental cell holder for in situ transmission electron microscopic (TEM) analysis is shown in this study. As in situ holders have only single-tilt capability, it is necessary to prepare the sample precisely along a specific zone axis. This can be achieved by a very accurate focused ion beam lift-out preparation. We show a step-by-step procedure to prepare the sample and transfer it into the gas environmental cell. The sample material is a GaP/Ga(NAsP)/GaP multi-quantum well structure on Si. Scanning TEM observations prove that it is possible to achieve atomic resolution at very high temperatures in a nitrogen environment of 100,000 Pa.

  1. Assessment of CCL2 and CXCL8 chemokines in serum, bronchoalveolar lavage fluid and lung tissue samples from dogs affected with canine idiopathic pulmonary fibrosis.

    Science.gov (United States)

    Roels, Elodie; Krafft, Emilie; Farnir, Frederic; Holopainen, Saila; Laurila, Henna P; Rajamäki, Minna M; Day, Michael J; Antoine, Nadine; Pirottin, Dimitri; Clercx, Cecile

    2015-10-01

    Canine idiopathic pulmonary fibrosis (CIPF) is a progressive disease of the lung parenchyma that is more prevalent in dogs of the West Highland white terrier (WHWT) breed. Since the chemokines (C-C motif) ligand 2 (CCL2) and (C-X-C motif) ligand 8 (CXCL8) have been implicated in pulmonary fibrosis in humans, the aim of the present study was to investigate whether these same chemokines are involved in the pathogenesis of CIPF. CCL2 and CXCL8 concentrations were measured by ELISA in serum and bronchoalveolar lavage fluid (BALF) from healthy dogs and WHWTs affected with CIPF. Expression of the genes encoding CCL2 and CXCL8 and their respective receptors, namely (C-C motif) receptor 2 (CCR2) and (C-X-C motif) receptor 2 (CXCR2), was compared in unaffected lung tissue and biopsies from dogs affected with CIPF by quantitative PCR and localisation of CCL2 and CXCL8 proteins were determined by immunohistochemistry. Significantly greater CCL2 and CXCL8 concentrations were found in the BALF from WHWTs affected with CIPF, compared with healthy dogs. Significantly greater serum concentrations of CCL2, but not CXCL8, were found in CIPF-affected dogs compared with healthy WHWTs. No differences in relative gene expression for CCL2, CXCL8, CCR2 or CXCR2 were observed when comparing lung biopsies from control dogs and those affected with CIPF. In affected lung tissues, immunolabelling for CCL2 and CXCL8 was observed in bronchial airway epithelial cells in dogs affected with CIPF. The study findings suggest that both CCL2 and CXCL8 are involved in the pathogenesis of CIPF. Further studies are required to determine whether these chemokines might have a clinical use as biomarkers of fibrosis or as targets for therapeutic intervention. Copyright © 2015 Elsevier Ltd. All rights reserved.

  2. Depleting high-abundant and enriching low-abundant proteins in human serum: An evaluation of sample preparation methods using magnetic nanoparticle, chemical depletion and immunoaffinity techniques.

    Science.gov (United States)

    de Jesus, Jemmyson Romário; da Silva Fernandes, Rafael; de Souza Pessôa, Gustavo; Raimundo, Ivo Milton; Arruda, Marco Aurélio Zezzi

    2017-08-01

    The efficiency of three different depletion methods to remove the most abundant proteins, enriching those human serum proteins with low abundance is checked to make more efficient the search and discovery of biomarkers. These methods utilize magnetic nanoparticles (MNPs), chemical reagents (sequential application of dithiothreitol and acetonitrile, DTT/ACN), and commercial apparatus based on immunoaffinity (ProteoMiner, PM). The comparison between methods shows significant removal of abundant protein, remaining in the supernatant at concentrations of 4.6±0.2, 3.6±0.1, and 3.3±0.2µgµL -1 (n=3) for MNPs, DTT/ACN and PM respectively, from a total protein content of 54µgµL -1 . Using GeLC-MS/MS analysis, MNPs depletion shows good efficiency in removing high molecular weight proteins (>80kDa). Due to the synergic effect between the reagents DTT and ACN, DTT/ACN-based depletion offers good performance in the depletion of thiol-rich proteins, such as albumin and transferrin (DTT action), as well as of high molecular weight proteins (ACN action). Furthermore, PM equalization confirms its efficiency in concentrating low-abundant proteins, decreasing the dynamic range of protein levels in human serum. Direct comparison between the treatments reveals 72 proteins identified when using MNP depletion (43 of them exclusively by this method), but only 20 proteins using DTT/ACN (seven exclusively by this method). Additionally, after PM treatment 30 proteins were identified, seven exclusively by this method. Thus, MNPs and DTT/ACN depletion can be simple, quick, cheap, and robust alternatives for immunochemistry-based protein depletion, providing a potential strategy in the search for disease biomarkers. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Metabolomic and Lipidomic Analysis of Serum Samples following Curcuma longa Extract Supplementation in High-Fructose and Saturated Fat Fed Rats.

    Directory of Open Access Journals (Sweden)

    Fabrice Tranchida

    Full Text Available We explored, using nuclear magnetic resonance (NMR metabolomics and fatty acids profiling, the effects of a common nutritional complement, Curcuma longa, at a nutritionally relevant dose with human use, administered in conjunction with an unbalanced diet. Indeed, traditional food supplements have been long used to counter metabolic impairments induced by unbalanced diets. Here, rats were fed either a standard diet, a high level of fructose and saturated fatty acid (HFS diet, a diet common to western countries and that certainly contributes to the epidemic of insulin resistance (IR syndrome, or a HFS diet with a Curcuma longa extract (1% of curcuminoids in the extract for ten weeks. Orthogonal projections to latent structures discriminant analysis (OPLS-DA on the serum NMR profiles and fatty acid composition (determined by GC/MS showed a clear discrimination between HFS groups and controls. This discrimination involved metabolites such as glucose, amino acids, pyruvate, creatine, phosphocholine/glycerophosphocholine, ketone bodies and glycoproteins as well as an increase of monounsaturated fatty acids (MUFAs and a decrease of n-6 and n-3 polyunsaturated fatty acids (PUFAs. Although the administration of Curcuma longa did not prevent the observed increase of glucose, triglycerides, cholesterol and insulin levels, discriminating metabolites were observed between groups fed HFS alone or with addition of a Curcuma longa extract, namely some MUFA and n-3 PUFA, glycoproteins, glutamine, and methanol, suggesting that curcuminoids may act respectively on the fatty acid metabolism, the hexosamine biosynthesis pathway and alcohol oxidation. Curcuma longa extract supplementation appears to be beneficial in these metabolic pathways in rats. This metabolomic approach highlights important serum metabolites that could help in understanding further the metabolic mechanisms leading to IR.

  4. Metabolomic and Lipidomic Analysis of Serum Samples following Curcuma longa Extract Supplementation in High-Fructose and Saturated Fat Fed Rats.

    Science.gov (United States)

    Tranchida, Fabrice; Shintu, Laetitia; Rakotoniaina, Zo; Tchiakpe, Léopold; Deyris, Valérie; Hiol, Abel; Caldarelli, Stefano

    2015-01-01

    We explored, using nuclear magnetic resonance (NMR) metabolomics and fatty acids profiling, the effects of a common nutritional complement, Curcuma longa, at a nutritionally relevant dose with human use, administered in conjunction with an unbalanced diet. Indeed, traditional food supplements have been long used to counter metabolic impairments induced by unbalanced diets. Here, rats were fed either a standard diet, a high level of fructose and saturated fatty acid (HFS) diet, a diet common to western countries and that certainly contributes to the epidemic of insulin resistance (IR) syndrome, or a HFS diet with a Curcuma longa extract (1% of curcuminoids in the extract) for ten weeks. Orthogonal projections to latent structures discriminant analysis (OPLS-DA) on the serum NMR profiles and fatty acid composition (determined by GC/MS) showed a clear discrimination between HFS groups and controls. This discrimination involved metabolites such as glucose, amino acids, pyruvate, creatine, phosphocholine/glycerophosphocholine, ketone bodies and glycoproteins as well as an increase of monounsaturated fatty acids (MUFAs) and a decrease of n-6 and n-3 polyunsaturated fatty acids (PUFAs). Although the administration of Curcuma longa did not prevent the observed increase of glucose, triglycerides, cholesterol and insulin levels, discriminating metabolites were observed between groups fed HFS alone or with addition of a Curcuma longa extract, namely some MUFA and n-3 PUFA, glycoproteins, glutamine, and methanol, suggesting that curcuminoids may act respectively on the fatty acid metabolism, the hexosamine biosynthesis pathway and alcohol oxidation. Curcuma longa extract supplementation appears to be beneficial in these metabolic pathways in rats. This metabolomic approach highlights important serum metabolites that could help in understanding further the metabolic mechanisms leading to IR.

  5. Smart management of sample dilution using an artificial neural network to achieve streamlined processes and saving resources: the automated nephelometric testing of serum free light chain as case study.

    Science.gov (United States)

    Ialongo, Cristiano; Pieri, Massimo; Bernardini, Sergio

    2017-02-01

    Saving resources is a paramount issue for the modern laboratory, and new trainable as well as smart technologies can be used to allow the automated instrumentation to manage samples more efficiently in order to achieve streamlined processes. In this regard the serum free light chain (sFLC) testing represents an interesting challenge, as it usually causes using a number of assays before achieving an acceptable result within the analytical range. An artificial neural network based on the multi-layer perceptron (MLP-ANN) was used to infer the starting dilution status of sFLC samples based on the information available through the laboratory information system (LIS). After the learning phase, the MLP-ANN simulation was applied to the nephelometric testing routinely performed in our laboratory on a BN ProSpec® System analyzer (Siemens Helathcare) using the N Latex FLC kit. The MLP-ANN reduced the serum kappa free light chain (κ-FLC) and serum lambda free light chain (λ-FLC) wasted tests by 69.4% and 70.8% with respect to the naïve stepwise dilution scheme used by the automated analyzer, and by 64.9% and 66.9% compared to a "rational" dilution scheme based on a 4-step dilution. Although it was restricted to follow-up samples, the MLP-ANN showed good predictive performance, which alongside the possibility to implement it in any automated system, made it a suitable solution for achieving streamlined laboratory processes and saving resources.

  6. Characterization of murine anti-human Fab antibodies for use in an immunoassay for generic quantification of human Fab fragments in non-human serum samples including cynomolgus monkey samples.

    Science.gov (United States)

    Stubenrauch, Kay; Wessels, Uwe; Essig, Ulrich; Kowalewsky, Frank; Vogel, Rudolf; Heinrich, Julia

    2013-01-01

    Generic immunoassay formats in animal serum have been described for pharmacokinetic (PK) analysis of human full-length antibodies, but not of human antigen binding fragment (Fab) proteins. Here we characterize two murine monoclonal antibodies (mAb) raised against human immunoglobulin G (IgG) which bind to unique epitopes in the Fab region of human IgG. mAb M-1.7.10 is directed against the constant domain of the kappa light chain and mAb M-1.19.31 binds to the constant domain 1 (CH1) of the heavy chain. Surface plasmon resonance analysis showed that mAb M-1.7.10 does not cross-react with sera from mouse, rat, rabbit, dog, marmoset, rhesus macaque, baboon and cynomolgus monkey, but binds to human and chimpanzee serum (dissociation constant K(D) of 6.8 × 10(-12) and 3.1 × 10(-11)M, respectively). mAb M-1.19.31 shows a higher K(D) for human and chimpanzee IgG (2.0 × 10(-9)M and 5.8 × 10(-10)M, respectively), but also does not bind to serum of the other species. Therefore, mAb M-1.7.10 was used as capture and mAb M-1.19.31 as detection reagent in a generic enzyme linked immunosorbent assay (ELISA) to quantify the human anti-IGF-1R Fab in mouse serum. The generic human Fab assay showed a limit of detection of 31.5 ng/mL anti-IGF-1R Fab. Intra- and inter-assay precision was less than 12% and the accuracy range for all controls was within ±20% of the target concentration. The generic human Fab ELISA was applied to determine serum levels of human anti-IGF-1R Fab after intravenous (iv) administration of 10mg/kg to mice. The resulting concentration-time profile was nearly identical to that obtained by analysis with a validated specific ELISA for anti-IGF-1R Fab. The mean relative concentration of anti-IGF-1R Fab analyzed by the generic assay was 82-118% of that of the specific assay. This equivalence was confirmed in a cynomolgus monkey study with the full length human mAb anti-TROP-2 IgG. Both specific ELISAs used mAb M-1.7.10 as detection reagent and their targets for

  7. Development of single step RT-PCR for detection of Kyasanur forest disease virus from clinical samples

    Directory of Open Access Journals (Sweden)

    Gouri Chaubal

    2018-02-01

    Discussion and conclusion: The previously published sensitive real time RT-PCR assay requires higher cost in terms of reagents and machine setup and technical expertise has been the primary reason for development of this assay. A single step RT-PCR is relatively easy to perform and more cost effective than real time RT-PCR in smaller setups in the absence of Biosafety Level-3 facility. This study reports the development and optimization of single step RT-PCR assay which is more sensitive and less time-consuming than nested RT-PCR and cost effective for rapid diagnosis of KFD viral RNA.

  8. A one-step separation of human serum high density lipoproteins 2 and 3 by rate-zonal density gradient ultracentrifugation in a swinging bucket rotor

    NARCIS (Netherlands)

    Groot, P.H.E.; Scheek, L.M.; Havekes, L.; Noort, W.L. van; Hooft, F.M. van 't

    1982-01-01

    A method was developed for the separation of the high density lipoprotein subclasses HDL2 and HDL3 from human serum. Six serum samples are fractionated in a single-step ultracentrifugal procedure using the Beckman (SW-40) swinging bucket rotor. The method is based on a difference in flotation rate

  9. Improved methodology for identification of protists and microalgae from plankton samples preserved in Lugol's iodine solution: combining microscopic analysis with single-cell PCR.

    Science.gov (United States)

    Auinger, Barbara M; Pfandl, Karin; Boenigk, Jens

    2008-04-01

    Here we introduce a method for quantitative analysis of planktonic protists and microalgae from preserved field samples combining morphological and small-subunit (SSU) rRNA gene sequence analysis. We linked a microscopic screening with PCR of single cells using field samples preserved with Lugol's iodine solution. Cells possessing a rigid cell wall were incubated with Viscozyme and subsequently with proteinase K for cell disruption; this was unnecessary for fragile cells. The addition of sodium thiosulfate to the PCR tube considerably decreased the inhibiting effect of the fixative (iodine) on the PCR and thus allowed for successful single-cell PCR even of long DNA fragments (up to as many as 3,000 base pairs). We further applied the protocol to investigate the dominant SSU rRNA genotypes in distinct flagellate morphospecies originating from different samples. We hypothesized that despite the morphological similarity, protist morphospecies in different habitats or sampled during different seasons are represented by different genotypes. Our results indicate species-specific differences: the two species Ochromonas sp. and Dinobryon divergens were represented by several different genotypes each, and for the latter species, the dominating genotype differed with habitat. In contrast, Dinobryon pediforme, Dinobryon bavaricum, and Synura sphagnicola were exclusively represented by a single genotype each, and the respective genotype was the same in different samples. In summary, our results highlight the significance of molecular variation within protist morphospecies.

  10. Improved Methodology for Identification of Protists and Microalgae from Plankton Samples Preserved in Lugol's Iodine Solution: Combining Microscopic Analysis with Single-Cell PCR▿ †

    Science.gov (United States)

    Auinger, Barbara M.; Pfandl, Karin; Boenigk, Jens

    2008-01-01

    Here we introduce a method for quantitative analysis of planktonic protists and microalgae from preserved field samples combining morphological and small-subunit (SSU) rRNA gene sequence analysis. We linked a microscopic screening with PCR of single cells using field samples preserved with Lugol's iodine solution. Cells possessing a rigid cell wall were incubated with Viscozyme and subsequently with proteinase K for cell disruption; this was unnecessary for fragile cells. The addition of sodium thiosulfate to the PCR tube considerably decreased the inhibiting effect of the fixative (iodine) on the PCR and thus allowed for successful single-cell PCR even of long DNA fragments (up to as many as 3,000 base pairs). We further applied the protocol to investigate the dominant SSU rRNA genotypes in distinct flagellate morphospecies originating from different samples. We hypothesized that despite the morphological similarity, protist morphospecies in different habitats or sampled during different seasons are represented by different genotypes. Our results indicate species-specific differences: the two species Ochromonas sp. and Dinobryon divergens were represented by several different genotypes each, and for the latter species, the dominating genotype differed with habitat. In contrast, Dinobryon pediforme, Dinobryon bavaricum, and Synura sphagnicola were exclusively represented by a single genotype each, and the respective genotype was the same in different samples. In summary, our results highlight the significance of molecular variation within protist morphospecies. PMID:18296536

  11. Relationship of serum insulin-like growth factor I (IGF-I) with nutritional status in pediatric patients with malignant diseases--a single Romanian center experience.

    Science.gov (United States)

    Chinceşan, Mihaela Ioana; Mărginean, Oana; Pitea, Ana-Maria; Dobreanu, Minodora

    2013-10-01

    The aim of this study was to analyze insulin-like growth factor I (IGF-I) serum level in pediatric patients with cancer compared with pediatric patients with nononcological diseases and to assess the relationship between IGF-I and nutritional status of oncological patients. From January 2009 to July 2012, we assessed 151 consecutively hospitalized patients in a tertiary emergency pediatric hospital. The patients were divided into two groups: group I, consisting of patients with malignant diseases (64 patients), and group II, the control group, consisting of 87 age- and gender-matched patients with different pediatric diseases. The anthropometric parameters (weight, height, body mass index, middle upper arm circumference (MUAC), and tricipital skinfold thickness (TST) and biochemical parameters (proteins, albumin, and total IGF-I) were comparatively evaluated at the diagnosis and after intensive chemotherapy in the malignant group. Anthropometric and biochemical parameters in group I were significantly different from those in group II for height, MUAC, TST, total proteins, and albumin (p patients with malignant diseases and 5 out of 87 patients in the control group had malnutrition. IGF-I in patients with cancer was much lower than in the control group (median 48.3 ng/ml, range 25.00-662.00 ng/ml vs 129.00 ng/ml, range 25.00-745.00 ng/ml) (p = 0.014). We found a positive correlation between IGF-I, MUAC, and TST at the diagnosis of the malignant disease. Also, we identified positive correlations between IGF-I, protein, and albumin. Serum IGF-I levels in cancer patients were significantly lower at diagnosis than after chemotherapy (48.3 ng/ml, range 25.00-662.00 ng/ml vs 110.0 ng/ml, range 25.00-573.00 ng/ml; p = 0.04). IGF-I seems to be an accurate biochemical parameter used in malnutrition assessment of children with cancer. IGF-I correlated with the anthropometric parameters of the arm, serum protein, and albumin. These parameters most accurately characterize the

  12. Hot topic: Bovine milk samples yielding negative or nonspecific results in bacterial culturing--the possible role of PCR-single strand conformation polymorphism in mastitis diagnosis.

    Science.gov (United States)

    Schwaiger, K; Wimmer, M; Huber-Schlenstedt, R; Fehlings, K; Hölzel, C S; Bauer, J

    2012-01-01

    A large proportion of mastitis milk samples yield negative or nonspecific results (i.e., no mastitis pathogen can be identified) in bacterial culturing. Therefore, the culture-independent PCR-single strand conformation polymorphism method was applied to the investigation of bovine mastitis milk samples. In addition to the known mastitis pathogens, the method was suitable for the detection of fastidious bacteria such as Mycoplasma spp., which are often missed by conventional culturing methods. The detection of Helcococcus ovis in 4 samples might indicate an involvement of this species in pathogenesis of bovine mastitis. In conclusion, PCR-single-strand conformation polymorphism is a promising tool for gaining new insights into the bacteriological etiology of mastitis. Copyright © 2012 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  13. [Detection of Coxiella burnetii in dairy cattle bulk tank milk and single tank milk samples by confirmatory testing].

    Science.gov (United States)

    Hilbert, Angela; Andres, Tatjana; Werner, Ralf; Wehr, Roswitha; Fröhlich, Andreas; Conraths, Franz J; Henning, Klaus

    2015-01-01

    Q fever is a worldwide zoonotic disease caused by the pathogen Coxiella (C.) burnetii. A wide range of animal species is susceptible to this intracellular bacterium with great importance in ruminants. Human infections occur mainly by airborne transmission. C burnetii was detected in animal products such as raw milk, raw-milk cheese and butter prepared from raw milk as well as in the meat of infected animals. In cattle milk, the pathogen was detected up to 13 months after calving. The risk of human foodborne C. Burnetii infection is still considered to be low, but cannot be completely ruled out and remains under discussion. The aim of this study was to compare different laboratory diagnostic methods for C. burnetii in milk sample. The bulk tank and individual milk samples were sent and studied at the National Reference Laboratory for Q-fever in the context of confirmatory laboratory testing after clinical suspicion or retesting of previously antibody detection was in the analysis of 888 individual milk samples a match of 93.3% (Cohen-kappa). A total of 173 bulk milk samples and 2,807 individual milk samples from bovine herds for the presence of C. burnetii DNA and antibodies were tested against the pathogen. The pathogen was detected in 62.5% of the bulk milk samples and up to 60% in individual milk samples. The highest proportion of positive bulk milks was determined as 68.3% in 2012. In individual milk samples, the highest proportion of seropositive samples was 62.2%.

  14. Prognostic Impact of Serum Heavy/Light Chain Pairs in Patients With Monoclonal Gammopathy of Undetermined Significance and Smoldering Myeloma: Long-Term Results From a Single Institution.

    Science.gov (United States)

    Magnano, Laura; Fernández de Larrea, Carlos; Elena, Montserrat; Cibeira, María Teresa; Tovar, Natalia; Aróstegui, Juan I; Pedrosa, Fabiola; Rosiñol, Laura; Filella, Xavier; Yagüe, Jordi; Bladé, Joan

    2016-06-01

    Asymptomatic monoclonal gammopathies, such as monoclonal gammopathy of undetermined significance (MGUS) and smoldering myeloma (SMM), are clinical conditions that usually precede symptomatic multiple myeloma. Therefore, risk stratification is crucial owing to the heterogeneous progression rate among these patients. In previous years, suppression of the uninvolved chain of specific heavy/light chain (HLC) pairs in serum has been identified as a new risk factor in MGUS. The aim of the present study was to investigate the prognostic effect of involved and uninvolved HLC pairs and HLC ratios on progression in a series of patients with MGUS and SMM. All specific serum HLC pairs were measured in 114 patients diagnosed with SMM (n = 27) and MGUS (n = 87) from 1983 to 2003. Also, the HLC ratios were calculated. Progression to symptomatic multiple myeloma was observed in 13 patients (8 with SMM and 5 with MGUS). The risk of progression was 6 times greater in those with SMM (P = .001) and 4 times greater for those with the IgA isotype (P = .01). The suppression of any IgM isotypes (IgMκ or IgMλ) in patients with IgA or IgG gammopathy or any IgA isotypes (IgAκ or IgAλ) in patients with IgG or IgM gammopathy was associated with a shorter time to progression to symptomatic gammopathy (P = .001 and P = .03, respectively). On multivariate analysis, the evolving pattern and suppression of any IgM HLC pair remained significant. HLC ratios could be a valuable tool in the risk stratification of patients with SMM and MGUS, especially patients with IgG isotypes. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. Sample preparation for semivolatile organics analysis of Hanford single-shell tank waste with high nitrate/nitrite and water content

    International Nuclear Information System (INIS)

    Stromatt, R.W.; Hoppe, E.W.; Steele, M.J.

    1993-11-01

    This report describes research work carried out to solve sample preparation problems associated with applying gas chromatography with mass spectrometric detection (GC/MS) to the analysis of single shell tank (SST) samples from Hanford for semivolatile organic compounds. Poor performance was found when applying the procedures based on the U.S. Environmental Protection Agency (EPA), Contract Laboratory Program, Statement of Work (CLP SOW). Analysis work was carried out on simulated drainable liquid modeled after the SST core samples which had evidenced analysis problems. Some work was also conducted on true SST samples. It was found that the pH range was too broad in the original procedure. It was also found that by decreasing the amount of methanol used in the extraction process, problems associated with the formation of an azeotrope phase could be avoided. The authors suggest a new procedure, whose eventual application to a wide array of SST samples will lend itself to better quality control limits

  16. Development of novel molecularly imprinted magnetic solid-phase extraction materials based on magnetic carbon nanotubes and their application for the determination of gatifloxacin in serum samples coupled with high performance liquid chromatography.

    Science.gov (United States)

    Xiao, Deli; Dramou, Pierre; Xiong, Nanqian; He, Hua; Li, Hui; Yuan, Danhua; Dai, Hao

    2013-01-25

    A novel composite imprinted material, on the basis of magnetic carbon nanotubes (MCNTs)-incorporated layer using gatifloxacin as a template, methacrylic acid as a functional monomer, and ethylene glycol dimethacrylate as a cross-linker, was successfully synthesized by a surface imprinting technique. Adsorption dynamics and a Scatchard adsorption model were employed to evaluate the adsorption process. The results showed that magnetic carbon nanotubes molecularly imprinted polymers (MCNTs@MIP) displayed a rapid dynamic adsorption and a high adsorption capacity of 192.7 μg/mg toward GTFX. Applied MCNTs@MIP as a sorbent, a magnetic solid phase extraction method coupled with high performance liquid chromatography (MSPE-HPLC) was developed for the determination of GTFX in serum samples. The recoveries from 79.1±4.8% to 85.3±4.2% were obtained. MCNTs@MIP can not only be collected and separated fast by external magnetic field but also have high surface-to-volume ratio, outstanding mechanical properties and specific recognition toward template molecule. In addition, the MCNTs@MIP could be regenerated, which could be used for five cycles with lost of less than 7.8% of its recovery on average. These analytical results of serum samples display that the proposed method based on MCNTs@MIP is applicable for fast and selective extraction of therapeutic agents from biological fluids. Copyright © 2012 Elsevier B.V. All rights reserved.

  17. Identification of a dengue virus type 2 (DEN-2) serotype-specific B-cell epitope and detection of DEN-2-immunized animal serum samples using an epitope-based peptide antigen.

    Science.gov (United States)

    Wu, Han-Chung; Jung, Mei-Ying; Chiu, Chien-Yu; Chao, Ting-Ting; Lai, Szu-Chia; Jan, Jia-Tsrong; Shaio, Men-Fang

    2003-10-01

    In this study, a serotype-specific monoclonal antibody (mAb), D(2) 16-1 (Ab4), against dengue virus type 2 (DEN-2) was generated. The specificity of Ab4, which recognized DEN-2 non-structural protein 1, was determined by ELISA, immunofluorescence and immunoblotting analyses. The serotype-specific B-cell epitope of Ab4 was identified further from a random phage-displayed peptide library; selected phage clones reacted specifically with Ab4 and did not react with other mAbs. Immunopositive phage clones displayed a consensus motif, His-Arg/Lys-Leu/Ile, and a synthetic peptide corresponding to the phage-displayed peptide bound specifically to Ab4. The His and Arg residues in this epitope were found to be crucial for peptide binding to Ab4 and binding activity decreased dramatically when these residues were changed to Leu. The epitope-based synthetic peptide not only identified serum samples from DEN-2-immunized mice and rabbits by ELISA but also differentiated clearly between serum samples from DEN-2- and Japanese encephalitis virus-immunized mice. This mAb and its epitope-based peptide antigen will be useful for serologic diagnosis of DEN-2 infection. Furthermore, DEN-2 epitope identification makes it feasible to dissect antibody responses to DEN and to address the role of antibodies in the pathogenesis of primary and secondary DEN-2 infections.

  18. Oral cancer screening: serum Raman spectroscopic approach

    Science.gov (United States)

    Sahu, Aditi K.; Dhoot, Suyash; Singh, Amandeep; Sawant, Sharada S.; Nandakumar, Nikhila; Talathi-Desai, Sneha; Garud, Mandavi; Pagare, Sandeep; Srivastava, Sanjeeva; Nair, Sudhir; Chaturvedi, Pankaj; Murali Krishna, C.

    2015-11-01

    Serum Raman spectroscopy (RS) has previously shown potential in oral cancer diagnosis and recurrence prediction. To evaluate the potential of serum RS in oral cancer screening, premalignant and cancer-specific detection was explored in the present study using 328 subjects belonging to healthy controls, premalignant, disease controls, and oral cancer groups. Spectra were acquired using a Raman microprobe. Spectral findings suggest changes in amino acids, lipids, protein, DNA, and β-carotene across the groups. A patient-wise approach was employed for data analysis using principal component linear discriminant analysis. In the first step, the classification among premalignant, disease control (nonoral cancer), oral cancer, and normal samples was evaluated in binary classification models. Thereafter, two screening-friendly classification approaches were explored to further evaluate the clinical utility of serum RS: a single four-group model and normal versus abnormal followed by determining the type of abnormality model. Results demonstrate the feasibility of premalignant and specific cancer detection. The normal versus abnormal model yields better sensitivity and specificity rates of 64 and 80% these rates are comparable to standard screening approaches. Prospectively, as the current screening procedure of visual inspection is useful mainly for high-risk populations, serum RS may serve as a useful adjunct for early and specific detection of oral precancers and cancer.

  19. Hepatitis B virus DNA quantification with the three-in-one (3io) method allows accurate single-step differentiation of total HBV DNA and cccDNA in biopsy-size liver samples.

    Science.gov (United States)

    Taranta, Andrzej; Tien Sy, Bui; Zacher, Behrend Johan; Rogalska-Taranta, Magdalena; Manns, Michael Peter; Bock, Claus Thomas; Wursthorn, Karsten

    2014-08-01

    Hepatitis B virus (HBV) replicates via reverse transcription converting its partially double stranded genome into the covalently closed circular DNA (cccDNA). The long-lasting cccDNA serves as a replication intermediate in the nuclei of hepatocytes. It is an excellent, though evasive, parameter for monitoring the course of liver disease and treatment efficiency. To develop and test a new approach for HBV DNA quantification in serum and small-size liver samples. The p3io plasmid contains an HBV fragment and human β-actin gene (hACTB) as a standard. Respective TaqMan probes were labeled with different fluorescent dyes. A triplex real-time PCR for simultaneous quantification of total HBV DNA, cccDNA and hACTB could be established. Three-in-one method allows simultaneous analysis of 3 targets with a lower limit of quantification of 48 copies per 20 μl PCR reaction and a wide range of linearity (R(2)>0.99, pDNA samples from HBV infected patients. Total HBV DNA and cccDNA could be quantified in 32 and 22 of 33 FFPE preserved liver specimens, respectively. Total HBV DNA concentrations quantified by the 3io method remained comparable with Cobas TaqMan HBV Test v2.0. The three-in-one protocol allows the single step quantification of viral DNA in samples from different sources. Therefore lower sample input, faster data acquisition, a lowered error and significantly lower costs are the advantages of the method. Copyright © 2014 Elsevier B.V. All rights reserved.

  20. An analysis of the relationship between serum cortisol and serum sodium in routine clinical patients

    Directory of Open Access Journals (Sweden)

    Eleanor McLaughlan

    2017-08-01

    Full Text Available Objectives: Adrenal insufficiency is an uncommon cause of hyponatraemia that should not be overlooked due to the severe consequences of an Addisonian crisis. Using the laboratory database of a large teaching hospital, we have explored the relationship between serum sodium and serum cortisol, and have estimated the frequency of hypoadrenalism in severely hyponatraemic patients. Design and methods: Data were gathered over a 23 month period from the Laboratory Information Management System at the Leeds Teaching Hospitals NHS Trust for instances where serum sodium and cortisol had been measured on a single sample. Data were also gathered over the same time period for all patients with severe hyponatraemia (serum sodium ≤120 mmol/L in order to determine the frequency of cortisol requesting and the incidence of adrenal insufficiency. Results: Analysis of the data (n=3268 patients revealed a trend showing higher cortisol concentrations in patients who were severely hypo- or hypernatraemic. The median cortisol concentration for patients with sodium ≤110 mmol/L was 856 nmol/L, and there was a gradual decrease in cortisol over the sodium range ≤110–150 mmol/L (Rs =−0.323, p<0.0001. Patients with sodium ≥151 mmol/L had a median cortisol of 725 nmol/L. 42% of the 978 patients with serum sodium ≤120 mmol/L had serum cortisol measured within two weeks, of whom 1.7% were diagnosed with adrenal insufficiency. Conclusions: This dataset shows rising cortisol in response to hypo- or hypernatraemia, in keeping with the stress response to illness. The data show that adrenal insufficiency is a rare cause of hyponatraemia which may be overlooked. Keywords: Serum, Sodium, Cortisol, Adrenal insufficiency

  1. Human serum albumin-coated gold nanoparticles for selective extraction of lysozyme from real-world samples prior to capillary electrophoresis.

    Science.gov (United States)

    Yeh, Pei-Rong; Tseng, Wei-Lung

    2012-12-14

    This study describes the use of human serum albumin (HSA)-modified gold nanoparticles (HSA-AuNPs) for the selective extraction and enrichment of high-pI protein, lysozyme (Lyz) prior to analysis by capillary electrophoresis (CE) with UV detection. HSA-AuNPs are capable of extracting Lyz from a complex matrix because a HSA capping layer not only stabilizes gold nanoparticles in a high-salt environment but also exhibits strong electrostatic attraction with Lyz under neutral pH condition. Efficient separation of Lyz and other high-pI proteins has been successfully achieved by the filling of cationic polyelectrolyte, poly(diallydimethylammonium chloride) (PDDAC), to the background electrolyte. After capturing Lyz with HSA-AuNPs, PDDAC-filled CE can be directly used for the analysis of the extracted Lyz without the addition of the releasing agent into the extractor. The extraction efficiency relied on the pH of the solution and the concentration of HSA-AuNPs. Under optimal extraction conditions, the limit of detection at a signal-to-noise ratio of 3 for Lyz was down to 8 nM. The combination of HSA-AuNP extraction and PDDAC-filled CE has been applied the analyses of Lyz in hen egg white, human milk, and human tear. Also, this NP-based extraction can be coupled to matrix-assisted desorption/ionization time-of-flight mass spectrometry and sodium dodecyl sulfate-polyacrylamide gel electrophoresis. Copyright © 2012 Elsevier B.V. All rights reserved.

  2. Single-molecule X-ray free-electron laser imaging : Interconnecting sample orientation with explosion data

    OpenAIRE

    Östlin, Christofer

    2014-01-01

    X-ray crystallography has been around for 100 years and remains the preferred technique for solving molecular structures today. However, its reliance on the production of sufficiently large crystals is limiting, considering that crystallization cannot be achieved for a vast range of biomolecules. A promising way of circumventing this problem is the method of serial femtosecond imaging of single-molecules or nanocrystals utilizing an X-ray free-electron laser. In such an approach, X-ray pulses...

  3. A novel method for single sample multi-axial nanoindentation of hydrated heterogeneous tissues based on testing great white shark jaws.

    Directory of Open Access Journals (Sweden)

    Toni L Ferrara

    Full Text Available Nanomechanical testing methods that are suitable for a range of hydrated tissues are crucial for understanding biological systems. Nanoindentation of tissues can provide valuable insights into biology, tissue engineering and biomimetic design. However, testing hydrated biological samples still remains a significant challenge. Shark jaw cartilage is an ideal substrate for developing a method to test hydrated tissues because it is a unique heterogeneous composite of both mineralized (hard and non-mineralized (soft layers and possesses a jaw geometry that is challenging to test mechanically. The aim of this study is to develop a novel method for obtaining multidirectional nanomechanical properties for both layers of jaw cartilage from a single sample, taken from the great white shark (Carcharodon carcharias. A method for obtaining multidirectional data from a single sample is necessary for examining tissue mechanics in this shark because it is a protected species and hence samples may be difficult to obtain. Results show that this method maintains hydration of samples that would otherwise rapidly dehydrate. Our study is the first analysis of nanomechanical properties of great white shark jaw cartilage. Variation in nanomechanical properties were detected in different orthogonal directions for both layers of jaw cartilage in this species. The data further suggest that the mineralized layer of shark jaw cartilage is less stiff than previously posited. Our method allows multidirectional nanomechanical properties to be obtained from a single, small, hydrated heterogeneous sample. Our technique is therefore suitable for use when specimens are rare, valuable or limited in quantity, such as samples obtained from endangered species or pathological tissues. We also outline a method for tip-to-optic calibration that facilitates nanoindentation of soft biological tissues. Our technique may help address the critical need for a nanomechanical testing method

  4. Combination of atomic force microscopy and mass spectrometry for the detection of target protein in the serum samples of children with autism spectrum disorders

    Science.gov (United States)

    Kaysheva, A. L.; Pleshakova, T. O.; Kopylov, A. T.; Shumov, I. D.; Iourov, I. Y.; Vorsanova, S. G.; Yurov, Y. B.; Ziborov, V. S.; Archakov, A. I.; Ivanov, Y. D.

    2017-10-01

    Possibility of detection of target proteins associated with development of autistic disorders in children with use of combined atomic force microscopy and mass spectrometry (AFM/MS) method is demonstrated. The proposed method is based on the combination of affine enrichment of proteins from biological samples and visualization of these proteins by AFM and MS analysis with quantitative detection of target proteins.

  5. Towards diffractive imaging with single pulses of FEL radiation. Dynamics within irradiatied samples and their influence on the analysis of imaging data

    International Nuclear Information System (INIS)

    Wang, Fenglin

    2010-08-01

    3D single particle coherent diffraction imaging (CDI) of bioparticles (such as proteins, macromolecules and viruses) is one of the main possible applications of the new generation of light sources: free-electron lasers (FELs), which are now available at FLASH (Hamburg, Germany) and LCLS (Stanford, U.S.A.). The extremely bright and ultrashort FEL pulses potentially enable CDI to achieve high resolution down to subnanometer length scale. However, intense FEL pulses cause serious radiation damage in bioparticles, even during single shots, which may set the resolution limits for CDI with FELs. Currently, since the signal-to-noise ratio is very low for small biological particles, direct experimental study of radiation damage in the single particle imaging is fairly difficult. Single atomic (noble gas) clusters become good objects to reveal effects of radiation damage processes on CDI with FEL radiation. This thesis studies three aspects of the radiation damage problem, which are treated in three independent chapters: (1) Molecular Dynamics simulations to quantitively describe radiation damage processes within irradiated atomic clusters during single pulses; (2) reconstruction analysis of single-shot CDI diffraction patterns of atomic clusters, which may potentially help to understand the radiation damage occurring in biological samples; and (3) testing the effects of coating water layers in CDI, which is supposed to minimize the radiation damage in irradiated bioparticles. (orig.)

  6. Towards diffractive imaging with single pulses of FEL radiation. Dynamics within irradiatied samples and their influence on the analysis of imaging data

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Fenglin

    2010-08-15

    3D single particle coherent diffraction imaging (CDI) of bioparticles (such as proteins, macromolecules and viruses) is one of the main possible applications of the new generation of light sources: free-electron lasers (FELs), which are now available at FLASH (Hamburg, Germany) and LCLS (Stanford, U.S.A.). The extremely bright and ultrashort FEL pulses potentially enable CDI to achieve high resolution down to subnanometer length scale. However, intense FEL pulses cause serious radiation damage in bioparticles, even during single shots, which may set the resolution limits for CDI with FELs. Currently, since the signal-to-noise ratio is very low for small biological particles, direct experimental study of radiation damage in the single particle imaging is fairly difficult. Single atomic (noble gas) clusters become good objects to reveal effects of radiation damage processes on CDI with FEL radiation. This thesis studies three aspects of the radiation damage problem, which are treated in three independent chapters: (1) Molecular Dynamics simulations to quantitively describe radiation damage processes within irradiated atomic clusters during single pulses; (2) reconstruction analysis of single-shot CDI diffraction patterns of atomic clusters, which may potentially help to understand the radiation damage occurring in biological samples; and (3) testing the effects of coating water layers in CDI, which is supposed to minimize the radiation damage in irradiated bioparticles. (orig.)

  7. A survey of feline leukaemia virus antigenaemia among cats in eastern Austria: a retrospective analysis of serum samples routinely tested between 1996 and 2011

    Directory of Open Access Journals (Sweden)

    Clair L Firth

    2015-07-01

    Full Text Available Objectives The aim of this retrospective analysis was to determine the seroprevalence of feline leukaemia virus (FeLV antigenaemia among owned cats in Vienna and the surrounding area. Methods Samples were tested between 1996 and 2011 by the Department of Clinical Virology at the University of Veterinary Medicine, Vienna, Austria. All samples were sent to the university as part of routine diagnostic procedures, either to determine infection in clinically symptomatic individuals or to rule out infection prior to vaccination. To allow for statistical comparison, samples analysed between 2008 and 2011 were pooled into one population (n = 444 and evaluated against samples tested in 1996 (n = 840. Furthermore, analyses of subgroups were undertaken to determine the effect of sex and age on the prevalence of FeLV antigenaemia. Results With respect to the samples tested at the University of Veterinary Medicine in Vienna, it was determined that the level of FeLV antigenaemia in eastern Austria between 1996 and 2011 was 5.6%. The proportion of FeLV antigenaemic cats was highly variable and has not fallen significantly over this period, despite advances in vaccination, and the education of pet owners and animal welfare charities. Conclusions and relevance This study confirms the importance of continued and regular vaccination against FeLV among Austrian cats, particularly those allowed access to the outdoors. Within the remit of this retrospective study, it was not possible to follow-up results of repeat testing or of other assays (PCR of individual cats. As a result of this, no conclusions can be drawn as to the possibility of transient antigenaemic cats or false-positive enzyme-linked immunosorbent assay results.

  8. Determination of the thermal neutron absorption cross section for rock samples by a single measurement of the time decay constant

    International Nuclear Information System (INIS)

    Krynicka, E.

    1993-01-01

    A calibration method for the determination of the thermal neutron macroscopic mass absorption cross section for rock samples is presented. The standard deviation of the final results is discussed in detail. A big advantage of the presented method is that the calibration curves have been found using the results obtained for a variety of natural rock samples of different stratigraphies and lithologies measured by Czubek's methods. An important part of the paper is a through analysis of the standard deviation of the final result. (author). 13 refs, 11 figs, 5 tabs

  9. Optimal sample size for predicting viability of cabbage and radish seeds based on near infrared spectra of single seeds

    DEFF Research Database (Denmark)

    Shetty, Nisha; Min, Tai-Gi; Gislum, René

    2011-01-01

    The effects of the number of seeds in a training sample set on the ability to predict the viability of cabbage or radish seeds are presented and discussed. The supervised classification method extended canonical variates analysis (ECVA) was used to develop a classification model. Calibration sub...... and radish data. The misclassification rates at optimal sample size were 8%, 6% and 7% for cabbage and 3%, 3% and 2% for radish respectively for random method (averaged for 10 iterations), DUPLEX and CADEX algorithms. This was similar to the misclassification rate of 6% and 2% for cabbage and radish obtained...

  10. Prediction of the systemic exposure to oral 9-amino-20(S)-camptothecin using single-sample analysis

    NARCIS (Netherlands)

    Sparreboom, A.; de Jonge, M. J.; Punt, C. J.; Loos, W. J.; Nooter, K.; Stoter, G.; Porro, M. G.; Verweij, J.

    1999-01-01

    The purpose of this study was to develop and validate limited-sampling strategies for prediction of the area under the plasma-concentration time curves (AUCs) of the lactone and total (i. e., lactone plus carboxylate) forms of the novel topoisomerase-I inhibitor 9-amino-20(S)-camptothecin (9-AC).

  11. Prediction of the systemic exposure to oral 9-amino-20(S)-camptothecin using single-sample analysis

    NARCIS (Netherlands)

    A. Sparreboom (Alex); M.J.A. de Jonge (Maja); C.J.A. Punt (Cornelis); W.J. Loos (Walter); K. Nooter (Kees); G. Stoter (Gerrit); M.G. Porro; J. Verweij (Jaap)

    1999-01-01

    textabstractThe purpose of this study was to develop and validate limited-sampling strategies for prediction of the area under the plasma-concentration time curves (AUCs) of the lactone and total (i. e., lactone plus carboxylate) forms of the novel topoisomerase-I

  12. Single Image Super-resolution Using Gaussian Process Regression with Dictionary-based Sampling and Student-t Likelihood.

    Science.gov (United States)

    Wang, Haijun; Gao, Xinbo; Zhang, Kaibing; Li, Jie

    2017-05-03

    Gaussian process regression (GPR) is an effective statistical learning method for modeling non-linear mapping from an observed space to an expected latent space. When applying it to example learning-based super-resolution (SR), two outstanding issues remain. One is its high computational complexity restricts SR application when a large dataset is available for learning task. The other is that the commonly used Gaussian likelihood in GPR is incompatible with the true observation model for SR reconstruction. To alleviate the above two issues, we propose a GPR-based SR method by using dictionary-based sampling and student-t likelihood, called DSGPR. Considering that dictionary atoms effectively span the original training sample space, we adopt a dictionary-based sampling strategy by combining all the neighborhood samples of each atom into a compact representative training subset so as to reduce the computational complexity. Based on statistical tests, we statistically validate that Studentt likelihood is more suitable to build the observation model for SR problem. Extensive experimental results show that the proposed method outperforms other competitors and produces more pleasing details in texture regions.

  13. Mites in dust samples from mattress surfaces from single beds or cribs in the south Brazilian city of Londrina.

    Science.gov (United States)

    da Silva, Dagoberto Ribeiro; Binotti, Raquel Soares; da Silva, Cleide Moreira; de Oliveira, Celso Henrique; Condino-Neto, Antônio; de Capitani, Eduardo Mello

    2005-03-01

    The aim of this study was to investigate the mite fauna in mattresses dust samples from cribs or beds in the south Brazilian city of Londrina, State of Parana. A total of 133 dust samples from upper and lower mattress surfaces, and bed frames were aspirated once from 38 dwellings (18 cribs and 21 beds), and one day nursery (six cribs). A total of 758 mite bodies were counted in slides: 233 (30.7%) from cribs and 525 (69.3%) from beds (pdust mites--mainly Dermatophagoides pteronyssinus, represented 72% and 84% of total mite count in crib and bed dust samples, respectively. The mean HDM body concentration in crib or bed slides were, respectively, 289.9+/-136.7 and 875.0+/-183.6 mites/g. Statistical analysis showed a significantly higher mite bodies count on lower mattress surface compared with upper surface in bed samples only (p=0.025). Data herein show that cribs like mattress have sufficient mite bodies to cause sensitization to humans. The use of mattress covers for cribs and beds should be encouraged in order to avoid allergens exposure. Copyright (c) 2005 Blackwell Munksgaard

  14. Single-shot all-optical sampling oscilloscope using a polarization-maintaining resonator for pulse replication

    Czech Academy of Sciences Publication Activity Database

    Komanec, M.; Honzátko, Pavel; Zvánovec, S.

    2010-01-01

    Roč. 52, č. 11 (2010), s. 2452-2456 ISSN 0895-2477 R&D Projects: GA AV ČR 1ET300670502 Institutional research plan: CEZ:AV0Z20670512 Keywords : optical sampling oscilloscope * four-wave mixing * fiber pulse replicator * highly nonlinear fiber Subject RIV: BH - Optics, Masers, Lasers Impact factor: 0.656, year: 2010

  15. Nanostructured conducting molecularly imprinted polymer for selective extraction of salicylate from urine and serum samples by electrochemically controlled solid-phase micro-extraction

    International Nuclear Information System (INIS)

    Ameli, Akram; Alizadeh, Naader

    2011-01-01

    Highlights: ► Overoxidized polypyrrole templated with salicylate has been utilized as conducting molecular imprinted polymer for EC-SPME. ► This first study reported on conducting molecular imprinted polymer was used to EC-SPME of salicylate. ► Proposed method, is particularly effective in sample clean-up and selective monitoring of salicylate in physiological samples. - Abstract: Overoxidized polypyrrole (OPPy) films templated with salicylate (SA) have been utilized as conducting molecular imprinted polymers (CMIPs) for potential-induced selective solid-phase micro-extraction processes. Various important fabrication factors for controlling the performance of the OPPy films have been investigated using fluorescence spectrometry. Several key parameters such as applied potential for uptake, release, pH of uptake and release solution were varied to achieve the optimum micro-extraction procedure. The film template with SA exhibited excellent selectivity over some interference. The calibration graphs were linear in the ranges of 5 × 10 −8 to 5 × 10 −4 and 1.2 × 10 −6 to 5 × 10 −4 mol mL −1 and the detection limit was 4 × 10 −8 mol L −1 . The OPPy film as the solid-phase micro-extraction absorbent has been applied for the selective clean-up and quantification of trace amounts of SA from physiological samples. The results of scanning electron microscopy (SEM) have confirmed the nano-structure morphologies of the films.

  16. Simple methodology to directly genotype Trypanosoma cruzi discrete typing units in single and mixed infections from human blood samples.

    Science.gov (United States)

    Bontempi, Iván A; Bizai, María L; Ortiz, Sylvia; Manattini, Silvia; Fabbro, Diana; Solari, Aldo; Diez, Cristina

    2016-09-01

    Different DNA markers to genotype Trypanosoma cruzi are now available. However, due to the low quantity of parasites present in biological samples, DNA markers with high copy number like kinetoplast minicircles are needed. The aim of this study was to complete a DNA assay called minicircle lineage specific-PCR (MLS-PCR) previously developed to genotype the T. cruzi DTUs TcV and TcVI, in order to genotype DTUs TcI and TcII and to improve TcVI detection. We screened kinetoplast minicircle hypervariable sequences from cloned PCR products from reference strains belonging to the mentioned DTUs using specific kDNA probes. With the four highly specific sequences selected, we designed primers to be used in the MLS-PCR to directly genotype T. cruzi from biological samples. High specificity and sensitivity were obtained when we evaluated the new approach for TcI, TcII, TcV and TcVI genotyping in twenty two T. cruzi reference strains. Afterward, we compared it with hybridization tests using specific kDNA probes in 32 blood samples from chronic chagasic patients from North Eastern Argentina. With both tests we were able to genotype 94% of the samples and the concordance between them was very good (kappa=0.855). The most frequent T. cruzi DTUs detected were TcV and TcVI, followed by TcII and much lower TcI. A unique T. cruzi DTU was detected in 18 samples meantime more than one in the remaining; being TcV and TcVI the most frequent association. A high percentage of mixed detections were obtained with both assays and its impact was discussed. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. Water absorption kinetics in different wettability conditions studied at pore and sample scales in porous media by NMR with portable single-sided and laboratory imaging devices

    Science.gov (United States)

    Bortolotti, V.; Camaiti, M.; Casieri, C.; De Luca, F.; Fantazzini, P.; Terenzi, C.

    2006-08-01

    NMR relaxation time distributions of water 1H obtained by a portable single-sided surface device have been compared with MRI internal images obtained with a laboratory imaging apparatus on the same biocalcarenite (Lecce Stone) samples during capillary water uptake. The aim of this work was to check the ability of NMR methods to quantitatively follow the absorption phenomenon under different wettability conditions of the internal pore surfaces. Stone wettability changes were obtained by capillary absorption of a chloroform solution of Paraloid PB72, a hydrophobic acrylic resin frequently used to protect monuments and buildings, through one face of each sample. Both relaxation and imaging data have been found in good quantitative agreement each other and with masses of water determined by weighing the samples. In particular the Washburn model of water capillary rise applied to the imaging data allowed us to quantify the sorptivity in both treated and untreated samples. Combining relaxation and imaging data, a synergetic improvement of our understanding of the water absorption kinetics at both pore and sample scales is obtained. Since relaxation data have been taken over the course of time without interrupting the absorption process, simply by keeping the portable device on the surface opposite to the absorption, the results show that the single-sided NMR technique is a powerful tool for in situ evaluation of water-repellent treatments frequently used for consolidation and/or protection of stone artifacts.

  18. Nanostructured conducting molecularly imprinted polymer for selective extraction of salicylate from urine and serum samples by electrochemically controlled solid-phase micro-extraction

    Energy Technology Data Exchange (ETDEWEB)

    Ameli, Akram [Department of Chemistry, Faculty of Science, Tarbiat Modares University, P.O. Box 14115-175, Tehran (Iran, Islamic Republic of); Alizadeh, Naader, E-mail: alizaden@modares.ac.ir [Department of Chemistry, Faculty of Science, Tarbiat Modares University, P.O. Box 14115-175, Tehran (Iran, Islamic Republic of)

    2011-11-30

    Highlights: Black-Right-Pointing-Pointer Overoxidized polypyrrole templated with salicylate has been utilized as conducting molecular imprinted polymer for EC-SPME. Black-Right-Pointing-Pointer This first study reported on conducting molecular imprinted polymer was used to EC-SPME of salicylate. Black-Right-Pointing-Pointer Proposed method, is particularly effective in sample clean-up and selective monitoring of salicylate in physiological samples. - Abstract: Overoxidized polypyrrole (OPPy) films templated with salicylate (SA) have been utilized as conducting molecular imprinted polymers (CMIPs) for potential-induced selective solid-phase micro-extraction processes. Various important fabrication factors for controlling the performance of the OPPy films have been investigated using fluorescence spectrometry. Several key parameters such as applied potential for uptake, release, pH of uptake and release solution were varied to achieve the optimum micro-extraction procedure. The film template with SA exhibited excellent selectivity over some interference. The calibration graphs were linear in the ranges of 5 Multiplication-Sign 10{sup -8} to 5 Multiplication-Sign 10{sup -4} and 1.2 Multiplication-Sign 10{sup -6} to 5 Multiplication-Sign 10{sup -4} mol mL{sup -1} and the detection limit was 4 Multiplication-Sign 10{sup -8} mol L{sup -1}. The OPPy film as the solid-phase micro-extraction absorbent has been applied for the selective clean-up and quantification of trace amounts of SA from physiological samples. The results of scanning electron microscopy (SEM) have confirmed the nano-structure morphologies of the films.

  19. Determination of the optional time for taking blood samples by single intravenous injection of 3H-leucine

    International Nuclear Information System (INIS)

    Meng Delian; Yao Junhu; Lu Jinyin; Wu Xiaobin; Liu Jun

    2003-01-01

    Twenty four young hens (1.5 kg of body weight, BW) were randomly divided into 4 groups. Every group was diet free (FAS) or force-fed a nitrogen-free diet (NFD) or the diet with 20% crude protein in which soybean meal or cotton seed meal was the sole nitrogen source (30 g DM/kg BW). 30 μCi 3 H-Leu/kg BW was intravenously injected into all birds just after force-fed or on fasting. Venous blood samples were taken at 5, 30 min, 4,24,36 and 48h after injection. The excreta during the whole period of 48h after injection was collected. Special radioactivities of nonprotein plasma at every time point and excreta were measured. The optional time of taking blood samples was 20-24 hours after injected 3 H-Leu

  20. Forensic Sampling and Analysis from a Single Substrate: Surface-Enhanced Raman Spectroscopy Followed by Paper Spray Mass Spectrometry.

    Science.gov (United States)

    Fedick, Patrick W; Bills, Brandon J; Manicke, Nicholas E; Cooks, R Graham

    2017-10-17

    Sample preparation is the most common bottleneck in the analysis and processing of forensic evidence. Time-consuming steps in many forensic tests involve complex separations, such as liquid and gas chromatography or various types of extraction techniques, typically coupled with mass spectrometry (e.g., LC-MS). Ambient ionization ameliorates these slow steps by reducing or even eliminating sample preparation. While some ambient ionization techniques have been adopted by the forensic community, there is significant resistance to discarding chromatography as most forensic analyses require both an identification and a confirmation technique. Here, we describe the use of a paper substrate, the surface of which has been inkjet printed with silver nanoparticles, for surface enhanced Raman spectroscopy (SERS). The same substrate can also act as the paper substrate for paper spray mass spectrometry. The coupling of SERS and paper spray ionization creates a quick, forensically feasible combination.

  1. Rapid Treponema pallidum clearance from blood and ulcer samples following single dose benzathine penicillin treatment of early syphilis.

    Science.gov (United States)

    Tipple, Craig; Jones, Rachael; McClure, Myra; Taylor, Graham

    2015-02-01

    Currently, the efficacy of syphilis treatment is measured with anti-lipid antibody tests. These can take months to indicate cure and, as a result, syphilis treatment trials require long periods of follow-up. The causative organism, Treponema pallidum (T. pallidum), is detectable in the infectious lesions of early syphilis using DNA amplification. Bacteraemia can likewise be identified, typically in more active disease. We hypothesise that bacterial clearance from blood and ulcers will predict early the standard serology-measured treatment response and have developed a qPCR assay that could monitor this clearance directly in patients with infectious syphilis. Patients with early syphilis were given an intramuscular dose of benzathine penicillin. To investigate the appropriate sampling timeframe samples of blood and ulcer exudate were collected intensively for T. pallidum DNA (tpp047 gene) and RNA (16S rRNA) quantification. Sampling ended when two consecutive PCRs were negative. Four males were recruited. The mean peak level of T. pallidum DNA was 1626 copies/ml whole blood and the mean clearance half-life was 5.7 hours (std. dev. 0.53). The mean peak of 16S rRNA was 8879 copies/ml whole blood with a clearance half-life of 3.9 hours (std. dev. 0.84). From an ulcer, pre-treatment, 67,400 T. pallidum DNA copies and 7.08 x 107 16S rRNA copies were detected per absorbance strip and the clearance half-lives were 3.2 and 4.1 hours, respectively. Overall, T. pallidum nucleic acids were not detected in any sample collected more than 56 hours (range 20-56) after treatment. All patients achieved serologic cure. In patients with active early syphilis, measuring T. pallidum levels in blood and ulcer exudate may be a useful measure of treatment success in therapeutic trials. These laboratory findings need confirmation on a larger scale and in patients receiving different therapies.

  2. A comparison of three fecal steroid metabolites for pregnancy detection used with single sampling in bighorn sheep (Ovis canadensis)

    Science.gov (United States)

    Schoenecker, K.A.; Lyda, R.O.; Kirkpatrick, J.

    2004-01-01

    We compared three fecal steroid metabolite assays for their usefulness in detecting pregnancy among free-ranging Rocky Mountain bighorn sheep (Ovis canadensis canadensis) from Bighorn Canyon National Recreation Area, Wyoming and Montana (USA) and captive bighorn ewes at ZooMontana in Billings, Montana. Fecal samples were collected from 11 free-ranging, radio-collared bighorn ewes in late January–May 2001 and from 20 free-ranging, radio-collared ewes in late March to mid-May 2002. Free-ranging ewes were monitored the following spring to determine whether or not they lambed. In addition, two captive ewes were studied at Zoo-Montana. With three exceptions, free-ranging bighorn ewes that produced lambs had nonspecific progesterone metabolite (iPdG) levels of >1,800 ng/g feces and iPdG levels >7,000 ng/gm feces when samples were collected between early March and mid-May Samples collected earlier in the year were inconclusive. One false negative was suspected to be the result of sample collection error. Of the captive ewes, nonspecific pregnanediol-3α–glucuronide (PdG) and iPdG followed a predictable curve over the course of the 180-day pregnancies. We conclude that estrone conjugates are not useful in diagnosing pregnancy; however, fecal steroid analysis of PdG and iPdG can be used to accurately determine pregnancy and reproductive function in bighorn sheep. This holds great potential as a noninvasive technique for understanding the role of reproductive disease in wild bighorn sheep.

  3. Detection and analysis of human serum albumin nanoparticles within phagocytic cells at the resolution of individual live cell or single 3D multicellular spheroid

    Energy Technology Data Exchange (ETDEWEB)

    Afrimzon, Elena; Zurgil, Naomi; Sobolev, Maria; Shafran, Yana [Bar-Ilan University, The Biophysical Interdisciplinary Schottenstein Center for the Research and Technology of the Cellome (Israel); Langer, Klaus; Zlatev, Iavor [Westfälischen Wilhelms-Universität Münster, Institut für Pharmazeutische Technologie und Biopharmazie (Germany); Wronski, Robert; Windisch, Manfred [QPS Austria GmbH (Austria); Briesen, Hagen von [Fraunhofer Institute for Biomedical Engineering IBMT, Department of Cell Biology & Applied Virology (Germany); Schmidt, Reinhold [Medical University of Graz, Department of Neurology (Austria); Pietrzik, Claus [University Medical Center of the Johannes Gutenberg University of Mainz, Institute of Pathobiochemistry (Germany); Deutsch, Mordechai, E-mail: motti.jsc@gmail.com [Bar-Ilan University, The Biophysical Interdisciplinary Schottenstein Center for the Research and Technology of the Cellome (Israel)

    2015-12-15

    Since nanoparticles (NPs) have shown great potential in various biomedical applications, live cell response to NPs should be thoroughly explored prior to their in vivo use. In the current study, live cell array (LCA) methodology and unique cell-based assays were used to study the interaction of magnetite (HSA-Mag NP) loaded human serum albumin NPs with phagocytic cells. The LCA enabled cell culturing during HSA-Mag NP accumulation and monolayer or spheroid formation, concomitantly with on-line monitoring of NP internalization. These platforms were also utilized for imaging intercellular links between living cells preloaded with HSA-Mag NP in 2D and 3D resolution. HSA-Mag NP uptake by cells was quantified by imaging, and analyzed using time-resolved measurements. Image analysis of the individual cells in cell populations showed accumulation of HSA-Mag NP by promonocytes and glial cells in a dose- and time-dependent manner. High variability of NP accumulation in individual cells within cell populations, as well as cell subgroups, was evident in both cell types. Following 24 h interaction, uptake of HSA-Mag NP was about 10 times more efficient in glial cells than in activated promonocytes. The presented assays may facilitate detection and analysis of the amount of NPs within individual cells, as well as the rate of NP accumulation and processing in different subsets of living cells. Such data are crucial for estimating predicted drug dosage delivered by NPs, as well as to study possible mechanisms for NP interference with live cells.

  4. Identification and genetic characterization of a novel circular single-stranded DNA virus in a human upper respiratory tract sample.

    Science.gov (United States)

    Cui, Lunbiao; Wu, Binyao; Zhu, Xiaojuan; Guo, Xiling; Ge, Yiyue; Zhao, Kangchen; Qi, Xian; Shi, Zhiyang; Zhu, Fengcai; Sun, Lixin; Zhou, Minghao

    2017-11-01

    Metagenomic analysis through high-throughput sequencing is a tool for detecting both known and novel viruses. Using this technique, a novel circular single-stranded DNA (ssDNA) virus genome was discovered in respiratory secretions from a febrile traveler. The virus, named human respiratory-associated PSCV-5-like virus (HRAPLV), has a genome comprising 3,018 bases, with two major putative ORFs inversely encoding capsid (Cap) and replicase (Rep) protein and separated by two intergenic regions. One stem-loop structure was predicted in the larger intergenic region (LIR). The predicted amino acid sequences of the Cap and Rep proteins of HRAPLV showed highest identity to those of porcine stool-associated circular virus 5 isolate CP3 (PoSCV 5) (53.0% and 48.9%, respectively). The host tropism of the virus is unknown, and further study is warranted to determine whether this novel virus is associated with human disease.

  5. Multifaceted empathy of healthy volunteers after single doses of MDMA: A pooled sample of placebo-controlled studies.

    Science.gov (United States)

    Kuypers, Kim Pc; Dolder, Patrick C; Ramaekers, Johannes G; Liechti, Matthias E

    2017-05-01

    Previous placebo-controlled experimental studies have shown that a single dose of MDMA can increase emotional empathy in the multifaceted empathy test (MET) without affecting cognitive empathy. Although sufficiently powered to detect main effects of MDMA, these studies were generally underpowered to also validly assess contributions of additional parameters, such as sex, drug use history, trait empathy and MDMA or oxytocin plasma concentrations. The present study examined the robustness of the MDMA effect on empathy and investigated the moderating role of these additional parameters. Participants ( n = 118) from six placebo-controlled within-subject studies and two laboratories were included in the present pooled analysis. Empathy (MET), MDMA and oxytocin plasma concentrations were assessed after oral administration of MDMA (single dose, 75 or 125 mg). Trait empathy was assessed using the interpersonal reactivity index. We confirmed that MDMA increased emotional empathy at both doses without affecting cognitive empathy. This MDMA-related increase in empathy was most pronounced during presentation of positive emotions as compared with negative emotions. MDMA-induced empathy enhancement was positively related to MDMA blood concentrations measured before the test, but independent of sex, drug use history and trait empathy. Oxytocin concentrations increased after MDMA administration but were not associated with behavioral effects. The MDMA effects on emotional empathy were stable across laboratories and doses. Sex did not play a moderating role in this effect, and oxytocin levels, trait empathy and drug use history were also unrelated. Acute drug exposure was of significant relevance in the MDMA-induced emotional empathy elevation.

  6. Efficient sampling of reversible cross-linking polymers: Self-assembly of single-chain polymeric nanoparticles

    Science.gov (United States)

    Oyarzún, Bernardo; Mognetti, Bortolo Matteo

    2018-03-01

    We present a new simulation technique to study systems of polymers functionalized by reactive sites that bind/unbind forming reversible linkages. Functionalized polymers feature self-assembly and responsive properties that are unmatched by the systems lacking selective interactions. The scales at which the functional properties of these materials emerge are difficult to model, especially in the reversible regime where such properties result from many binding/unbinding events. This difficulty is related to large entropic barriers associated with the formation of intra-molecular loops. In this work, we present a simulation scheme that sidesteps configurational costs by dedicated Monte Carlo moves capable of binding/unbinding reactive sites in a single step. Cross-linking reactions are implemented by trial moves that reconstruct chain sections attempting, at the same time, a dimerization reaction between pairs of reactive sites. The model is parametrized by the reaction equilibrium constant of the reactive species free in solution. This quantity can be obtained by means of experiments or atomistic/quantum simulations. We use the proposed methodology to study the self-assembly of single-chain polymeric nanoparticles, starting from flexible precursors carrying regularly or randomly distributed reactive sites. We focus on understanding differences in the morphology of chain nanoparticles when linkages are reversible as compared to the well-studied case of irreversible reactions. Intriguingly, we find that the size of regularly functionalized chains, in good solvent conditions, is non-monotonous as a function of the degree of functionalization. We clarify how this result follows from excluded volume interactions and is peculiar of reversible linkages and regular functionalizations.

  7. Evaluation of the Aptima HBV Quant assay vs. the COBAS TaqMan HBV test using the high pure system for the quantitation of HBV DNA in plasma and serum samples.

    Science.gov (United States)

    Schalasta, Gunnar; Börner, Anna; Speicher, Andrea; Enders, Martin

    2018-03-28

    Proper management of patients with chronic hepatitis B virus (HBV) infection requires monitoring of plasma or serum HBV DNA levels using a highly sensitive nucleic acid amplification test. Because commercially available assays differ in performance, we compared herein the performance of the Hologic Aptima HBV Quant assay (Aptima) to that of the Roche Cobas TaqMan HBV test for use with the high pure system (HPS/CTM). Assay performance was assessed using HBV reference panels as well as plasma and serum samples from chronically HBV-infected patients. Method correlation, analytical sensitivity, precision/reproducibility, linearity, bias and influence of genotype were evaluated. Data analysis was performed using linear regression, Deming correlation analysis and Bland-Altman analysis. Agreement between the assays for the two reference panels was good, with a difference in assay values vs. target 0.98). The two assays had similar bias and precision across the different genotypes tested at low viral loads (25-1000 IU/mL). Aptima has a performance comparable with that of HPS/CTM, making it suitable for use for HBV infection monitoring. Aptima runs on a fully automated platform (the Panther system) and therefore offers a significantly improved workflow compared with HPS/CTM.

  8. Evolving microstructure, magnetic properties and phase transition in a mechanically alloyed Ni0.5Zn0.5Fe2O4 single sample

    Science.gov (United States)

    Ismail, Ismayadi; Hashim, Mansor; Kanagesan, Samikannu; Ibrahim, Idza Riati; Nazlan, Rodziah; Wan Ab Rahman, Wan Norailiana; Abdullah, Nor Hapishah; Mohd Idris, Fadzidah; Bahmanrokh, Ghazaleh; Shafie, Mohd Shamsul Ezzad; Manap, Masni

    2014-02-01

    We report on an investigation to unravel the dependence of magnetic properties on microstructure while they evolve in parallel under the influence of sintering temperature of a single sample of Ni0.5Zn0.5Fe2O4 synthesized via mechanical alloying. A single sample, instead of the normally practiced approach of using multiple samples, was sintered at various sintering temperatures from 500 °C to 1400 °C. The morphology of the samples was studied by means of scanning electron microscopy (SEM) equipped with EDX; density measurement was conducted using the Archimedes principle; and hysteresis measurement was carried out using a B-H hysteresisgraph system. XRD data showed that the first appearance of a single phase was at 800 °C and an amorphous phase was traced at lower sintering temperatures. We correlated the microstructure and the magnetic properties and showed that the important grain-size threshold for the appearance of significant ordered magnetism (mainly ferromagnetism) was about ≥0.3 µm. We found that there were three stages of magnetic phase evolution produced via the sintering process with increasing temperatures. The first stage was dominated by paramagnetic states with some superparamagnetic behavior; the second stage was influenced by moderately ferromagnetic states and some paramagnetic states; and the third stage consisted of strongly ferromagnetic states with negligible paramagnetic states. We found that three factors sensitively influenced the sample's content of ordered magnetism—the ferrite-phase crystallinity degree, the number of grains above the critical grain size and the number of large enough grains for domain wall accommodation.

  9. A single laboratory setup for investigating the anisotropy of both seismic and electrical properties in core samples

    Science.gov (United States)

    David, Christian; Robion, Philippe; Louis, Laurent

    2017-09-01

    A fully automated versatile device is presented for analysing the anisotropy of both seismic and electrical properties on cylindrical rock samples. Initially devoted to the study of P-wave velocity anisotropy (APV), the system has been upgraded to allow the measurement of electrical conductivity anisotropy (AEC) as well. The improved setup allows for the estimation of the APV and AEC, from measurements across multiple diameters with an angular spacing selected by the operator. In order to determine the APV simplified tensor and the true AEC tensor, at least three mutually orthogonal samples are required. Switching from velocity to electrical measurements only requires replacing the pair of ultrasonic transducers by a pair of electrodes. Whereas the procedure is quite straightforward for the P-wave velocity analysis, different calibration steps and approximations are required in the processing of the electrical data. As an example the methodology was applied to a set of two rocks, the Leopard and the Castlegate sandstones, for which the APV and AEC are compared in a unified scheme. Good agreement was found between the orientation of the symmetry axes for both properties, suggesting that in the studied rocks pore space anisotropy accounts for both velocity and electrical anisotropy. This methodology can also be incorporated into a core analysis workflow to obtain a first-hand assessment of the rock fabric orientation and anisotropy with respect to seismic and transport properties. The information thus obtained can be used as a screening step for sampling and stress testing as well as for direct core to log integration and cross-property correlations.

  10. Rapid Treponema pallidum clearance from blood and ulcer samples following single dose benzathine penicillin treatment of early syphilis.

    Directory of Open Access Journals (Sweden)

    Craig Tipple

    2015-02-01

    Full Text Available Currently, the efficacy of syphilis treatment is measured with anti-lipid antibody tests. These can take months to indicate cure and, as a result, syphilis treatment trials require long periods of follow-up. The causative organism, Treponema pallidum (T. pallidum, is detectable in the infectious lesions of early syphilis using DNA amplification. Bacteraemia can likewise be identified, typically in more active disease. We hypothesise that bacterial clearance from blood and ulcers will predict early the standard serology-measured treatment response and have developed a qPCR assay that could monitor this clearance directly in patients with infectious syphilis. Patients with early syphilis were given an intramuscular dose of benzathine penicillin. To investigate the appropriate sampling timeframe samples of blood and ulcer exudate were collected intensively for T. pallidum DNA (tpp047 gene and RNA (16S rRNA quantification. Sampling ended when two consecutive PCRs were negative. Four males were recruited. The mean peak level of T. pallidum DNA was 1626 copies/ml whole blood and the mean clearance half-life was 5.7 hours (std. dev. 0.53. The mean peak of 16S rRNA was 8879 copies/ml whole blood with a clearance half-life of 3.9 hours (std. dev. 0.84. From an ulcer, pre-treatment, 67,400 T. pallidum DNA copies and 7.08 x 107 16S rRNA copies were detected per absorbance strip and the clearance half-lives were 3.2 and 4.1 hours, respectively. Overall, T. pallidum nucleic acids were not detected in any sample collected more than 56 hours (range 20-56 after treatment. All patients achieved serologic cure. In patients with active early syphilis, measuring T. pallidum levels in blood and ulcer exudate may be a useful measure of treatment success in therapeutic trials. These laboratory findings need confirmation on a larger scale and in patients receiving different therapies.

  11. Single-particle characterization of ice-nucleating particles and ice particles residuals sampled by three different techniques

    Science.gov (United States)

    Kandler, Konrad; Worringen, Annette; Benker, Nathalie; Dirsch, Thomas; Mertes, Stephan; Schenk, Ludwig; Kästner, Udo; Frank, Fabian; Nillius, Björn; Bundke, Ulrich; Rose, Diana; Curtius, Joachim; Kupiszewski, Piotr; Weingartner, Ernest; Vochezer, Paul; Schneider, Johannes; Schmidt, Susan; Weinbruch, Stephan; Ebert, Martin

    2015-04-01

    During January/February 2013, at the High Alpine Research Station Jungfraujoch a measurement campaign was carried out, which was centered on atmospheric ice-nucleating particles (INP) and ice particle residuals (IPR). Three different techniques for separation of INP and IPR from the non-ice-active particles are compared. The Ice Selective Inlet (ISI) and the Ice Counterflow Virtual Impactor (Ice-CVI) sample ice particles from mixed phase clouds and allow for the analysis of the residuals. The combination of the Fast Ice Nucleus Chamber (FINCH) and the Ice Nuclei Pumped Counterflow Virtual Impactor (IN-PCVI) provides ice-activating conditions to aerosol particles and extracts the activated INP for analysis. Collected particles were analyzed by scanning electron microscopy and energy-dispersive X-ray microanalysis to determine size, chemical composition and mixing state. All INP/IPR-separating techniques had considerable abundances (median 20 - 70 %) of instrumental contamination artifacts (ISI: Si-O spheres, probably calibration aerosol; Ice-CVI: Al-O particles; FINCH+IN-PCVI: steel particles). Also, potential sampling artifacts (e.g., pure soluble material) occurred with a median abundance of metal oxides were the major INP/IPR particle types separated by all three techniques. Soot was a minor contributor. Lead was detected in less than 10 % of the particles, of which the majority were internal mixtures with other particle types. Sea-salt and sulfates were identified by all three methods as INP/IPR. Most samples showed a maximum of the INP/IPR size distribution at 400 nm geometric diameter. In a few cases, a second super-micron maximum was identified. Soot/carbonaceous material and metal oxides were present mainly in the submicron range. ISI and FINCH yielded silicates and Ca-rich particles mainly with diameters above 1 µm, while the Ice-CVI also separated many submicron IPR. As strictly parallel sampling could not be performed, a part of the discrepancies between

  12. Two-dimensional strandness-dependent electrophoresis: a method to characterize single-stranded DNA, double-stranded DNA, and RNA-DNA hybrids in complex samples.

    Science.gov (United States)

    Gunnarsson, Gudmundur H; Gudmundsson, Bjarki; Thormar, Hans G; Alfredsson, Arni; Jonsson, Jon J

    2006-03-01

    We describe two-dimensional strandness-dependent electrophoresis (2D-SDE) for quantification and length distribution analysis of single-stranded (ss) DNA fragments, double-stranded (ds) DNA fragments, RNA-DNA hybrids, and nicked DNA fragments in complex samples. In the first dimension nucleic acid molecules are separated based on strandness and length in the presence of 7 M urea. After the first-dimension electrophoresis all nucleic acid fragments are heat denatured in the gel. During the second-dimension electrophoresis all nucleic acid fragments are single-stranded and migrate according to length. 2D-SDE takes about 90 min and requires only basic skills and equipment. We show that 2D-SDE has many applications in analyzing complex nucleic acid samples including (1) estimation of renaturation efficiency and kinetics, (2) monitoring cDNA synthesis, (3) detection of nicked DNA fragments, and (4) estimation of quality and in vitro damage of nucleic acid samples. Results from 2D-SDE should be useful to validate techniques such as complex polymerase chain reaction, subtractive hybridization, cDNA synthesis, cDNA normalization, and microarray analysis. 2D-SDE could also be used, e.g., to characterize biological nucleic acid samples. Information obtained with 2D-SDE cannot be readily obtained with other methods. 2D-SDE can be used for preparative isolation of ssDNA fragments, dsDNA fragments, and RNA-DNA hybrids.

  13. Simultaneous estimation of population receptive field and hemodynamic parameters from single point BOLD responses using Metropolis-Hastings sampling.

    Science.gov (United States)

    Adaszewski, Stanisław; Slater, David; Melie-Garcia, Lester; Draganski, Bogdan; Bogorodzki, Piotr

    2018-01-30

    We introduce a new approach to Bayesian pRF model estimation using Markov Chain Monte Carlo (MCMC) sampling for simultaneous estimation of pRF and hemodynamic parameters. To obtain high performance on commonly accessible hardware we present a novel heuristic consisting of interpolation between precomputed responses for predetermined stimuli and a large cross-section of receptive field parameters. We investigate the validity of the proposed approach with respect to MCMC convergence, tuning and biases. We compare different combinations of pRF - Compressive Spatial Summation (CSS), Dumoulin-Wandell (DW) and hemodynamic (5-parameter and 3-parameter Balloon-Windkessel) models within our framework with and without the usage of the new heuristic. We evaluate estimation consistency and log probability across models. We perform as well a comparison of one model with and without lookup table within the RStan framework using its No-U-Turn Sampler. We present accelerated computation of whole-ROI parameters for one subject. Finally, we discuss risks and limitations associated with the usage of the new heuristic as well as the means of resolving them. We found that the new algorithm is a valid sampling approach to joint pRF/hemodynamic parameter estimation and that it exhibits very high performance. Copyright © 2018. Published by Elsevier Inc.

  14. Single-particle characterization of ice-nucleating particles and ice particle residuals sampled by three different techniques

    Science.gov (United States)

    Worringen, A.; Kandler, K.; Benker, N.; Dirsch, T.; Mertes, S.; Schenk, L.; Kästner, U.; Frank, F.; Nillius, B.; Bundke, U.; Rose, D.; Curtius, J.; Kupiszewski, P.; Weingartner, E.; Vochezer, P.; Schneider, J.; Schmidt, S.; Weinbruch, S.; Ebert, M.

    2015-04-01

    In the present work, three different techniques to separate ice-nucleating particles (INPs) as well as ice particle residuals (IPRs) from non-ice-active particles are compared. The Ice Selective Inlet (ISI) and the Ice Counterflow Virtual Impactor (Ice-CVI) sample ice particles from mixed-phase clouds and allow after evaporation in the instrument for the analysis of the residuals. The Fast Ice Nucleus Chamber (FINCH) coupled with the Ice Nuclei Pumped Counterflow Virtual Impactor (IN-PCVI) provides ice-activating conditions to aerosol particles and extracts the activated particles for analysis. The instruments were run during a joint field campaign which took place in January and February 2013 at the High Alpine Research Station Jungfraujoch (Switzerland). INPs and IPRs were analyzed offline by scanning electron microscopy and energy-dispersive X-ray microanalysis to determine their size, chemical composition and mixing state. Online analysis of the size and chemical composition of INP activated in FINCH was performed by laser ablation mass spectrometry. With all three INP/IPR separation techniques high abundances (median 20-70%) of instrumental contamination artifacts were observed (ISI: Si-O spheres, probably calibration aerosol; Ice-CVI: Al-O particles; FINCH + IN-PCVI: steel particles). After removal of the instrumental contamination particles, silicates, Ca-rich particles, carbonaceous material and metal oxides were the major INP/IPR particle types obtained by all three techniques. In addition, considerable amounts (median abundance mostly a few percent) of soluble material (e.g., sea salt, sulfates) were observed. As these soluble particles are often not expected to act as INP/IPR, we consider them as potential measurement artifacts. Minor types of INP/IPR include soot and Pb-bearing particles. The Pb-bearing particles are mainly present as an internal mixture with other particle types. Most samples showed a maximum of the INP/IPR size distribution at 200

  15. A novel antibody–antigen based impedimetric immunosensor for low level detection of HER2 in serum samples of breast cancer patients via modification of a gold nanoparticles decorated multiwall carbon nanotube-ionic liquid electrode

    Energy Technology Data Exchange (ETDEWEB)

    Arkan, Elham [Nano Drug Delivery Research Center, Kermanshah University of Medical Sciences, Kermanshah (Iran, Islamic Republic of); Saber, Reza [Department of Medical Nanotechnology, School of Advanced Medical Technologies, Tehran University of Medical Sciences, Tehran (Iran, Islamic Republic of); Research Center for Science and Technology in Medicine, Imam Khomeini Hospital, Tehran (Iran, Islamic Republic of); Karimi, Ziba [Department of Chemistry, Payame Noor University, P.O. Box 19395-3697, Tehran (Iran, Islamic Republic of); Shamsipur, Mojtaba, E-mail: mshamsipur@yahoo.com [Department of Chemistry, Razi University, Kermanshah (Iran, Islamic Republic of)

    2015-05-18

    Highlights: • Design of a novel impedimetric immunosensor for detection of HER2 in serum samples. • Use of a multiwall carbon nanotube-ionic liquid electrode modified with AuNPs as a base. • Immobilization of monoclonal HER2 antibody on AuNPs/MWCILE using 1,6-hexanedithiol as a cross linker. • Achieving linear dynamic range and limit of detection of 10–110 ng mL{sup −1} and 7.4 ng mL{sup −1}, respectively. • Method development and validation and application to assay of HER2 in biological fluids. - Abstract: A highly sensitive impedimetric immunosensor based on a gold nanoparticles/multiwall carbon nanotube-ionic liquid electrode (AuNPs/MW-CILE) was developed for the determination of human epidermal growth factor receptor 2 (HER2). Gold nanoparticles were used to enhance the extent of immobilization and to retain the immunoactivity of the antibody Herceptin on the electrode. Cyclic voltammetry and electrochemical impedance spectroscopy were employed for characterization of various layers coated onto the AuNPs/MW-CILE. The impedance measurements at different steps were based on the charge transfer kinetics of the [Fe(CN){sub 6}]{sup 3−/4−} redox pair. The immobilization of antibody and the corresponding antigen–antibody interaction at the electrode surface altered the interfacial electron transfer. The interactions of antibody with various concentrations of antigen were also monitored via the change of impedance response. The results showed that the charge transfer resistance increases linearly with increasing concentrations of HER2 antigen. The linear range and limit of detection were found as 10–110 ng mL{sup −1} and 7.4 ng mL{sup −1}, respectively. The sensitivity and specificity of the immunosensor were validated. The results showed that the prepared immunosensor is a useful tool for screening of trace amounts of HER2 in serum samples of breast cancer patients.

  16. Simultaneous determination of uric acid, xanthine, hypoxanthine and caffeine in human blood serum and urine samples using electrochemically reduced graphene oxide modified electrode.

    Science.gov (United States)

    Raj, M Amal; John, S Abraham

    2013-04-10

    This paper describes the fabrication of graphene on glassy carbon electrode (GCE) by electrochemical reduction of graphene oxide (GO) attached through 1,6-hexadiamine on GCE and the simultaneous determination of structurally similar four purine derivatives using the resultant electrochemically reduced GO (ERGO) modified electrode. The electrocatalytic activity of ERGO was investigated toward the oxidation of four important purine derivatives, uric acid (UA), xanthine (XN), hypoxanthine (HXN) and caffeine (CAF) at physiological pH. The modified electrode not only enhanced the oxidation currents of the four purine derivatives but also shifted their oxidation potentials toward less positive potentials in contrast to bare GCE. Further, it successfully separates the voltammetric signals of the four purine derivatives in a mixture and hence used for the simultaneous determination of them. Selective determination of one purine derivative in the presence of low concentrations other three purine derivatives was also realized at the present modified electrode. Using differential pulse voltammetry, detection limits of 8.8×10(-8)M, 1.1×10(-7)M, 3.2×10(-7)M and 4.3×10(-7)M were obtained for UA, XN, HXN and CAF, respectively. The practical application of the modified electrode was demonstrated by simultaneously determining the concentrations of UA, XN, HXN and CAF in human blood plasma and urine samples. Copyright © 2013 Elsevier B.V. All rights reserved.

  17. Diagnostic possibilities from a serum sample-Clinical value of new methods within small animal reproduction, with focus on anti-Müllerian hormone.

    Science.gov (United States)

    Holst, B S

    2017-04-01

    During the last decade, analysis of anti-Müllerian hormone (AMH), highly conserved between mammalian species, has contributed to new information in reproductive endocrinology, due to clinically available diagnostic assays. AMH is produced solely in the gonads, in the Sertoli cells of testes and granulosa cells of the ovary, and thus offers possibilities to diagnose physiologic and pathologic conditions involving these organs. This article reviews indications for AMH analysis in cats and dogs, including diagnosing the presence of gonads, and granulosa or Sertoli cell tumours. Diagnostic challenges are addressed. One specific organ, the prostate, is commonly affected by pathologic changes in older dogs. A commercial assay for analysing canine prostatic specific esterase (CPSE) enables analysis of CPSE in clinical practice, of potential value in the workup of benign prostatic hyperplasia in male dogs. This is described in this review, as is a new method for analysis of steroids: liquid chromatography-tandem mass spectrometry LC-MS/MS. Steroids have since long been analysed in studies on reproduction, and LC-MS/MS has the advantage of allowing analysis of panels of multiple steroids from small sample volumes. Altogether, these available methods may give new insights into small animal reproduction and are valuable tools for the practicing veterinarian. © 2016 Blackwell Verlag GmbH.

  18. A Single-Chip 64-Channel Ultrasound RX-Beamformer Including Analog Front-End and an LUT for Non-Uniform ADC-Sample-Clock Generation.

    Science.gov (United States)

    Kim, Yoon-Jee; Cho, Sung-Eun; Um, Ji-Yong; Chae, Min-Kyun; Bang, Jihoon; Song, Jongkeun; Jeon, Taeho; Kim, Byungsub; Sim, Jae-Yoon; Park, Hong-June

    2017-02-01

    A 64-channel RX digital beamformer was implemented in a single chip for 3-D ultrasound medical imaging using 2-D phased-array transducers. The RX beamformer chip includes 64 analog front-end branches including 64 non-uniform sampling ADCs, a FIFO/Adder, and an on-chip look-up table (LUT). The LUT stores the information on the rising edge timing of the non-uniform ADC sampling clocks. To include the LUT inside the beamformer chip, the LUT size was reduced by around 240 times by approximating an ADC-sample-time profile w.r.t. focal points (FP) along a scanline (SL) for a channel into a piece-wise linear form. The maximum error between the approximated and accurate sample times of ADC is eight times the sample time resolution (Ts) that is 1/32 of the ultrasound signal period in this work. The non-uniform sampling reduces the FIFO size required for digital beamforming by around 20 times. By applying a 9-dot image from Field-II program and 2-D ultrasound phantom images to the fabricated RX beamformer chip, the original images were successfully reconstructed from the measured output. The chip in a 0.13-um CMOS occupies 30.25 [Formula: see text] and consumes 605 mW.

  19. Precise determination of sodium in serum by simulated isotope dilution method of inductively coupled plasma mass spectrometry

    International Nuclear Information System (INIS)

    Yan Ying; Zhang Chuanbao; Zhao Haijian; Chen Wenxiang; Shen Ziyu; Wang Xiaoru; Chen Dengyun

    2007-01-01

    A new precise and accurate method for the determination of sodium in serum by inductively coupled plasma mass spectrometry (ICP-MS) was developed. Since 23 Na is the single isotope element, 27 Al is selected as simulated isotope of Na. Al is spiked into serum samples and Na standard solution. 23 Na/ 27 Al ratio in the Na standard solution is determined to assume the natural Na isotope ratio. The serums samples are digested by purified HNO 3 /H 2 O 2 and diluted to get about 0.6 μg·g -1 Al solutions, and the 23 Na/ 27 Al ratios of the serum samples are obtained to calculate the accurate Na concentrations basing on the isotope dilution method. When the simulated isotope dilution method of ICP-MS is applied and Al is selected as the simulated isotope of Na, the precise and accurate Na concentrations in the serums are determined. The inter-day precision of CV<0.13% for one same serum sample is obtained during 3 days 4 measurements. The spike recoveries are between 99.69% and 100.60% for 4 different serum samples and 3 days multi-measurements. The results of measuring standard reference materials of serum sodium are agree with the certified value. The relative difference between 3 days is 0.22%-0.65%, and the relative difference in one bottle is 0.15%-0.44%. The ICP-MS and Al simulated isotope dilution method is proved to be not only precise and accurate, but also quick and convenient for measuring Na in serum. It is promising to be a reference method for precise determination of Na in serum. Since Al is a low cost isotope dilution reagent, the method is possible to be widely applied for serum Na determination. (authors)

  20. Non-Destructive Study of Bulk Crystallinity and Elemental Composition of Natural Gold Single Crystal Samples by Energy-Resolved Neutron Imaging

    Science.gov (United States)

    Tremsin, Anton S.; Rakovan, John; Shinohara, Takenao; Kockelmann, Winfried; Losko, Adrian S.; Vogel, Sven C.

    2017-01-01

    Energy-resolved neutron imaging enables non-destructive analyses of bulk structure and elemental composition, which can be resolved with high spatial resolution at bright pulsed spallation neutron sources due to recent developments and improvements of neutron counting detectors. This technique, suitable for many applications, is demonstrated here with a specific study of ~5–10 mm thick natural gold samples. Through the analysis of neutron absorption resonances the spatial distribution of palladium (with average elemental concentration of ~0.4 atom% and ~5 atom%) is mapped within the gold samples. At the same time, the analysis of coherent neutron scattering in the thermal and cold energy regimes reveals which samples have a single-crystalline bulk structure through the entire sample volume. A spatially resolved analysis is possible because neutron transmission spectra are measured simultaneously on each detector pixel in the epithermal, thermal and cold energy ranges. With a pixel size of 55 μm and a detector-area of 512 by 512 pixels, a total of 262,144 neutron transmission spectra are measured concurrently. The results of our experiments indicate that high resolution energy-resolved neutron imaging is a very attractive analytical technique in cases where other conventional non-destructive methods are ineffective due to sample opacity. PMID:28102285

  1. Serum ferritin

    International Nuclear Information System (INIS)

    Rochna Viola, E.M.; Diaz de Domingo, N.B.; Lazarowski, A.

    1981-01-01

    Serum ferritin (SF) concentration as determined by the immunoradiometric method allows the direct measurement of a fraction of the body ferritin pool. In normal subjects, SF is an excellent index of body iron stores. In certain conditions associated with increased ferritin synthesis (such as liver disease, inflammation, malignancy, chronic disorders, ineffective erythropoiesis, or during ferrotherapy), SF may not accurately reflect body iron stores. In hyposideremic anemias SF concentration permits to differentiate those due to iron deficiency from those due to chronic disorders. With a good assay quality, subnormal SF levels are incontrovertible in the diagnosis of iron deficiency. SF determination has been investigated as possible tumor marker. When performed in combination with the alpha-fetoprotein assay, SF enhances the specificity of serodiagnosis of hepatoma. SF results must be interpreted bearing in mind the possible participation of circumstances that i) modify the body iron stores and ii) lead to increased ferritin synthesis. (author) [es

  2. Isolation and cloning of exendin precursor cDNAs from single samples of venom from the Mexican beaded lizard (Heloderma horridum) and the Gila monster (Heloderma suspectum).

    Science.gov (United States)

    Chen, Tianbao; Kwok, Hangfai; Ivanyi, Craig; Shaw, Chris

    2006-03-01

    Reptile venoms are complex cocktails of bioactive molecules, including peptides. While the drug discovery potential of most species remains unrealized, many are endangered and afforded protection under international treaties. In this study, we describe how potential clinically important bioactive peptides and their corresponding mRNAs can be structurally characterized from single, small samples of reptile venom. The potential type-2 diabetes therapeutics, exendin-3 and exendin-4, from the Mexican beaded lizard (Heloderma horridum) and the Gila monster (Heloderma suspectum), respectively, have been characterized at both protein and nucleic acid levels to illustrate the efficacy of the technique and its contribution to biodiversity conservation.

  3. Relative effectiveness of kinetic analysis vs single point readings for classifying environmental samples based on community-level physiological profiles (CLPP)

    Science.gov (United States)

    Garland, J. L.; Mills, A. L.; Young, J. S.

    2001-01-01

    The relative effectiveness of average-well-color-development-normalized single-point absorbance readings (AWCD) vs the kinetic parameters mu(m), lambda, A, and integral (AREA) of the modified Gompertz equation fit to the color development curve resulting from reduction of a redox sensitive dye from microbial respiration of 95 separate sole carbon sources in microplate wells was compared for a dilution series of rhizosphere samples from hydroponically grown wheat and potato ranging in inoculum densities of 1 x 10(4)-4 x 10(6) cells ml-1. Patterns generated with each parameter were analyzed using principal component analysis (PCA) and discriminant function analysis (DFA) to test relative resolving power. Samples of equivalent cell density (undiluted samples) were correctly classified by rhizosphere type for all parameters based on DFA analysis of the first five PC scores. Analysis of undiluted and 1:4 diluted samples resulted in misclassification of at least two of the wheat samples for all parameters except the AWCD normalized (0.50 abs. units) data, and analysis of undiluted, 1:4, and 1:16 diluted samples resulted in misclassification for all parameter types. Ordination of samples along the first principal component (PC) was correlated to inoculum density in analyses performed on all of the kinetic parameters, but no such influence was seen for AWCD-derived results. The carbon sources responsible for classification differed among the variable types with the exception of AREA and A, which were strongly correlated. These results indicate that the use of kinetic parameters for pattern analysis in CLPP may provide some additional information, but only if the influence of inoculum density is carefully considered. c2001 Elsevier Science Ltd. All rights reserved.

  4. Identification of Genotype 3 Hepatitis E Virus (HEV) in Serum and Fecal Samples from Pigs in Thailand and Mexico, Where Genotype 1 and 2 HEV Strains Are Prevalent in the Respective Human Populations

    Science.gov (United States)

    Cooper, K.; Huang, F. F.; Batista, L.; Rayo, C. D.; Bezanilla, J. C.; Toth, T. E.; Meng, X. J.

    2005-01-01

    Hepatitis E virus (HEV), the causative agent of hepatitis E, is an important public health concern in many developing countries. Increasing evidence indicates that hepatitis E is a zoonotic disease. There exist four major genotypes of HEV, and HEV isolates identified in samples from pigs belong to either genotype 3 or 4. Genotype 1 and 2 HEVs are found exclusively in humans. To determine whether genotype 1 and 2 HEVs also exist in pigs, a universal reverse transcription-PCR assay that is capable of detecting all four HEV genotypes was used to test for the presence of HEV RNA in serum and/or fecal samples from pigs in Thailand, where genotype 1 human HEV is prevalent, and from pigs in Mexico, where genotype 2 human HEV was epidemic. In Thailand, swine HEV RNA was detected in sera from 10/26 pigs of 2 to 4 months of age but not in sera from 50 pigs of other ages. In Mexico, swine HEV RNA was detected in 8/125 sera and 28/92 fecal samples from 2- to 4-month-old pigs. Antibodies to swine HEV were also detected in about 81% of the Mexican pigs. A total of 44 swine HEV isolates were sequenced for the open reading frame 2 gene region. Sequence analyses revealed that all swine HEV isolates identified in samples from pigs in Thailand and Mexico belong to genotype 3. Phylogenetic analyses revealed that minor branches associated with geographic origin exist among the swine HEV isolates. The results indicated that genotype 1 or 2 swine HEV does not exist in pigs from countries where the respective human HEV genotype 1 or 2 is prevalent. It is likely that only genotype 3 and 4 HEV strains have zoonotic potential. PMID:15814985

  5. A precise evaluation of glomerular filtration rate (GFR) in two plasma samples following a single administration of 57Co-B12 vitamin

    International Nuclear Information System (INIS)

    Camargo, E.E.; Rockmann, R.L.; Barreto, T.M.; Eston, T.E.; Papaleo Netto, M.; Carvalho, N.

    1974-01-01

    Through a logarithmic regression performed with the contings of 4 plasma samples withdrawn at 20,40,60 and 80 minutes after a venous injection of vitamin B 12 - 57 Co, the glomerular filtration-rate(GFR) in 11 patients, performing simultaneously the same study with EDTA- 51 Cr in 3 of them, is evaluated. The values obtained through the regression straight line are compared with those given by only 2 points, in the 6 possible combinations: 20 and 40 minutes, 20 and 60 minutes, 20 and 80 minutes, 40 and 60 minutes, 40 and 80 minutes, 60 and 80 minutes. The pair of points obtained at 20 and 80 minutes determined the straight line most similar to the logarithmic regression and as a simplification of the method, the withdraw of only 2 plasma samples, at and 80 minutes after a single injection of vitamin B 12 -57 Co is proposed [pt

  6. Trace analysis of mefenamic acid in human serum and pharmaceutical wastewater samples after pre-concentration with Ni–Al layered double hydroxide nano-particles

    Directory of Open Access Journals (Sweden)

    Hossein Abdolmohammad-Zadeh

    2014-10-01

    Full Text Available In this work, the nickel–aluminum layered double hydroxide (Ni–Al LDH with nitrate interlayer anion was synthesized and used as a solid phase extraction sorbent for the selective separation and pre-concentration of mefenamic acid prior to quantification by UV detection at λmax=286 nm. Extraction procedure is based on the adsorption of mefenamate anions on the Ni–Al(NO3− LDH and/or their exchange with LDH interlayer NO3− anions. The effects of several parameters such as cations and interlayer anions type in LDH structure, pH, sample flow rate, elution conditions, amount of nano-sorbent and co-existing ions on the extraction were investigated and optimized. Under the optimum conditions, the calibration graph was linear within the range of 2–1000 µg/L with a correlation coefficient of 0.9995. The limit of detection and relative standard deviation were 0.6 µg/L and 0.84% (30 µg/L, n=6, respectively. The presented method was successfully applied to determine of mefenamic acid in human serum and pharmaceutical wastewater samples. Keywords: Mefenamic acid, Solid phase extraction, Nano-sorbent, Nickel-aluminum layered double hydroxide, Ultraviolet spectroscopy

  7. Radioimmunoassay for serum paraquat

    International Nuclear Information System (INIS)

    Fatori, D.; Hunter, W.M.

    1980-01-01

    Two variants of a radioimmunoassay for the bipyridylium herbicide Paraquat are described. Both employ antiserum raised to Paraquat-BSA which has been covalently linked to particulate solid-phase support media. The rapid assay for clinical use employs a [ 3 H] Paraquat tracer, requires no agitation and yields results in the range 10-2500 ng/ml serum in 20 min from receipt of sample. The more sensitive assay, designed for research purposes, employs a 125 iodinated tracer, requires 2 h continuous agitation but can detect Paraquat at 0.1 ng/ml in simple aqueous solution or 0.25 ng/ml serum. Results from rapid clinical assay agree well with the existing colorimetric method. (Auth.)

  8. Reversed-phase single drop microextraction followed by high-performance liquid chromatography with fluorescence detection for the quantification of synthetic phenolic antioxidants in edible oil samples.

    Science.gov (United States)

    Farajmand, Bahman; Esteki, Mahnaz; Koohpour, Elham; Salmani, Vahid

    2017-04-01

    The reversed-phase mode of single drop microextraction has been used as a preparation method for the extraction of some phenolic antioxidants from edible oil samples. Butylated hydroxyl anisole, tert-butylhydroquinone and butylated hydroxytoluene were employed as target compounds for this study. High-performance liquid chromatography followed by fluorescence detection was applied for final determination of target compounds. The most interesting feature of this study is the application of a disposable insulin syringe with some modification for microextraction procedure that efficiently improved the volume and stability of the solvent microdrop. Different parameters such as the type and volume of solvent, sample stirring rate, extraction temperature, and time were investigated and optimized. Analytical performances of the method were evaluated under optimized conditions. Under the optimal conditions, relative standard deviations were between 4.4 and 10.2%. Linear dynamic ranges were 20-10 000 to 2-1000 μg/g (depending on the analytes). Detection limits were 5-670 ng/g. Finally, the proposed method was successfully used for quantification of the antioxidants in some edible oil samples prepared from market. Relative recoveries were achieved from 88 to 111%. The proposed method had a simplicity of operation, low cost, and successful application for real samples. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. Relationship between single and multiple perpetrator rape perpetration in South Africa: A comparison of risk factors in a population-based sample.

    Science.gov (United States)

    R, Jewkes; Y, Sikweyiya; K, Dunkle; R, Morrell

    2015-07-07

    Studies of rape of women seldom distinguish between men's participation in acts of single and multiple perpetrator rape. Multiple perpetrator rape (MPR) occurs globally with serious consequences for women. In South Africa it is a cultural practice with defined circumstances in which it commonly occurs. Prevention requires an understanding of whether it is a context specific intensification of single perpetrator rape, or a distinctly different practice of different men. This paper aims to address this question. We conducted a cross-sectional household study with a multi-stage, randomly selected sample of 1686 men aged 18-49 who completed a questionnaire administered using an Audio-enhanced Personal Digital Assistant. We attempted to fit an ordered logistic regression model for factors associated with rape perpetration. 27.6 % of men had raped and 8.8 % had perpetrated multiple perpetrator rape (MPR). Thus 31.9 % of men who had ever raped had done so with other perpetrators. An ordered regression model was fitted, showing that the same associated factors, albeit at higher prevalence, are associated with SPR and MPR. Multiple perpetrator rape appears as an intensified form of single perpetrator rape, rather than a different form of rape. Prevention approaches need to be mainstreamed among young men.

  10. Current sharing temperature of NbTi SULTAN samples compared to prediction using a single pinning mechanism parametrization for NbTi strand

    International Nuclear Information System (INIS)

    Pong, Ian; Vostner, Alexander; Devred, Arnaud; Bessette, Denis; Mitchell, Neil; Bordini, Bernardo; Bottura, Luca; Jewell, Matthew; Long Feng; Wu Yu

    2012-01-01

    NbTi strands to be used in four of the six ITER poloidal field (PF) coils, all the correction coils (CC) and all the superconducting feeder busbars are being produced in China. Short full-size qualification conductor (cabled and jacketed) samples have been developed at ASIPP and tested at CRPP. Single pinning mechanism parametrization for this Chinese strand (type S2) has been obtained using the Bottura scaling law. The determination of the scaling parameters using a Kramer-type regression method will be described. A comparison between the critical temperature at the operating current and field of a single strand as determined by the parametrization and the current sharing temperature (T CS ) of a few conductor samples tested at the SULTAN facility will be made. The validity and limitation of the estimation will be discussed. The estimated T CS dependence on various (superconducting critical as well as geometric and volumetric) parameters will be assessed using the modelled critical surface. Errors propagated from critical current (I c ) measurements of the strands and parameter fitting, and other uncertainties, will be quantified. (paper)

  11. Replica exchange enveloping distribution sampling (RE-EDS): A robust method to estimate multiple free-energy differences from a single simulation.

    Science.gov (United States)

    Sidler, Dominik; Schwaninger, Arthur; Riniker, Sereina

    2016-10-21

    In molecular dynamics (MD) simulations, free-energy differences are often calculated using free energy perturbation or thermodynamic integration (TI) methods. However, both techniques are only suited to calculate free-energy differences between two end states. Enveloping distribution sampling (EDS) presents an attractive alternative that allows to calculate multiple free-energy differences in a single simulation. In EDS, a reference state is simulated which "envelopes" the end states. The challenge of this methodology is the determination of optimal reference-state parameters to ensure equal sampling of all end states. Currently, the automatic determination of the reference-state parameters for multiple end states is an unsolved issue that limits the application of the methodology. To resolve this, we have generalised the replica-exchange EDS (RE-EDS) approach, introduced by Lee et al. [J. Chem. Theory Comput. 10, 2738 (2014)] for constant-pH MD simulations. By exchanging configurations between replicas with different reference-state parameters, the complexity of the parameter-choice problem can be substantially reduced. A new robust scheme to estimate the reference-state parameters from a short initial RE-EDS simulation with default parameters was developed, which allowed the calculation of 36 free-energy differences between nine small-molecule inhibitors of phenylethanolamine N-methyltransferase from a single simulation. The resulting free-energy differences were in excellent agreement with values obtained previously by TI and two-state EDS simulations.

  12. Simultaneous determination of PPCPs, EDCs, and artificial sweeteners in environmental water samples using a single-step SPE coupled with HPLC-MS/MS and isotope dilution.

    Science.gov (United States)

    Tran, Ngoc Han; Hu, Jiangyong; Ong, Say Leong

    2013-09-15

    A high-throughput method for the simultaneous determination of 24 pharmaceuticals and personal care products (PPCPs), endocrine disrupting chemicals (EDCs) and artificial sweeteners (ASs) was developed. The method was based on a single-step solid phase extraction (SPE) coupled with high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) and isotope dilution. In this study, a single-step SPE procedure was optimized for simultaneous extraction of all target analytes. Good recoveries (≥ 70%) were observed for all target analytes when extraction was performed using Chromabond(®) HR-X (500 mg, 6 mL) cartridges under acidic condition (pH 2). HPLC-MS/MS parameters were optimized for the simultaneous analysis of 24 PPCPs, EDCs and ASs in a single injection. Quantification was performed by using 13 isotopically labeled internal standards (ILIS), which allows correcting efficiently the loss of the analytes during SPE procedure, matrix effects during HPLC-MS/MS and fluctuation in MS/MS signal intensity due to instrument. Method quantification limit (MQL) for most of the target analytes was below 10 ng/L in all water samples. The method was successfully applied for the simultaneous determination of PPCPs, EDCs and ASs in raw wastewater, surface water and groundwater samples collected in a local catchment area in Singapore. In conclusion, the developed method provided a valuable tool for investigating the occurrence, behavior, transport, and the fate of PPCPs, EDCs and ASs in the aquatic environment. Copyright © 2013 Elsevier B.V. All rights reserved.

  13. Bilateral vanished testes diagnosed with a single blood sample showing very high gonadotropins (follicle-stimulating hormone and luteinizing hormone) and very low inhibin B

    DEFF Research Database (Denmark)

    Thorup, Jørgen Mogens; Petersen, Bodil Laub; Kvist, Kolja

    2011-01-01

    Objective. In boys with cryptorchidism median serum values of follicle-stimulating hormone (FSH) and luteinizing hormone (LH) are higher and median serum values of inhibin B lower than in normal controls. Serum values of inhibin B reflect the state of germinative epithelium in cryptorchid testes...... with bilateral cryptorchidism younger than 7 years of age at surgery for bilateral cryptorchidism (median age 1 year and 9 months). Results. The serum levels of hormones for the patients with vanished testes were: inhibin B 5-18 pg/ml, FSH 41-191 IU/l and LH 3.9-56 IU/l. The patients all had karyotype 46,xy....... The serum levels of hormones from group II were: inhibin B median 122 (range 20-404) pg/ml, FSH median 0.8 (range 0.2-3.5) IU/l and LH median 0.2 (range 0.1-3.2) IU/l. The serum levels of inhibin B, FSH and LH from the boys with vanished testes were significantly different from the serum levels of the boys...

  14. Single-beam integrating sphere spectrophotometer for reflectance and transmittance measurements versus angle of incidence in the solar wavelength range on diffuse and specular samples

    Science.gov (United States)

    Nostell, Per; Roos, Arne; Rönnow, Daniel

    1999-05-01

    A multipurpose instrument for the measurement of reflectance and transmittance versus angle of incidence for both specular and diffuse samples in the solar wavelength range has been constructed and evaluated. The instrument operates in the single-beam mode and uses a common light source for three experimental setups. Two integrating spheres, 20 cm in diameter, are used for diffuse transmittance and reflectance measurements. The transmittance sphere can be turned around an axis through the sample to vary the angle of incidence. The reflectance sphere uses a center mounted sample and a special feature is the position of the detector, which is mounted on the sample holder at the center of the sphere. This way the detector always sees the same part of the sphere wall and no light can reach the detector directly from the sample. The third setup is an absolute instrument for specular samples. It uses a small averaging sphere as a detector. The detector is mounted on an arm which rotates around the center of the sample, and it can thus pick up both the reflected and transmitted beams including all multiply reflected components. The averaging sphere detector is insensitive to small side shifts of the detected beams and no multiple reflections between detector and optical system occur. In this report a number of calibration procedures are presented for the three experimental setups and models for the calculation of correct transmittance and reflectance values from measured data are presented. It is shown that for integrating sphere measurements, the geometry of the sphere and the diffusivity of the sample as well as the sphere wall reflectance and port losses are important factors that influence the result. For the center mounted configuration these factors are particularly important and special emphasis is given to the evaluation of the reflectance sphere model. All three instrument setups are calibrated using certified reference materials and nonscattering mirrors and

  15. Aflatoxin B1-lysine adduct in dried blood spot samples of animals and humans.

    Science.gov (United States)

    Xue, Kathy S; Cai, Wenjie; Tang, Lili; Wang, Jia-Sheng

    2016-12-01

    Dried blood spots (DBS) were proposed as potentially viable method for exposure assessment of environmental toxicants in infant and young children. For this study, we validated an experimental protocol to quantify AFB 1 -lysine adduct in DBS samples of AFB 1 -treated F344 rats, as well as samples from human field study. Significant dose-response relationships in AFB 1 -lysine adduct formation were found in DBS samples of rats treated with single- and repeated-dose AFB 1 . AFB 1 -lysine levels in DBS samples were highly correlated with corresponding serum sample levels. The Person coefficients were 0.997 for the single-dose exposure, and 0.996 for the repeated-dose exposure. Levels of AFB 1 -lysine adduct had also good agreement between DBS and serum samples as shown by Bland-Altman plot analysis. For human field study samples (n = 36), a Pearson correlation coefficient of 0.784 was found between AFB 1 -lysine adduct levels of DBS and corresponding serum samples. Bland-Altman plots showed the distribution of the log differences between DBS and serum AFB 1 -lysine levels are within 95% confidence intervals. These results showed AFB 1 -lysine adduct levels in DBS cards and serum samples from animals and human samples are comparable, and the DBS technique and analytical protocol is a good means to assess AFB 1 exposure in infant and children populations. Copyright © 2016 Elsevier Ltd. All rights reserved.

  16. Serum Vitamin A Levels in Patients with Chalazion.

    Science.gov (United States)

    Malekahmadi, Mohammad; Farrahi, Fereydoun; Tajdini, Afshin

    2017-01-01

    Chalazion is a chronic, localized lipogranulomatous inflammation of the sebaceous glands of the lids. Chalazion occurs often secondary to blockage of the sebaceous gland ducts. Some studies have reported vitamin A deficiency as a risk factor for chalazion. In this study, we determined the serum levels of vitamin A in patients with chalazion. The study involved a total of 107 subjects (52 patients with chalazion and 55 control healthy subjects). The study was conducted at the Ophthalmology Clinics of Imam Khomeini Hospital, Ahwaz Jundishapur University of Medical Sciences, Ahwaz, Iran between September 2014 and February 2015. The subjects were divided into three groups according to age: 7-12 years old, 13-19 years old, and more than 19 years old. Patients were further divided into four subgroups based on the type of chalazion: single, multiple, primary, and recurrent. Blood samples were collected and the serum was tested for levels of vitamin A using high-performance liquid chromatography (HPLC). The average serum vitamin A levels in patients with chalazion in the age groups of 7-12 and 13-19 years were significantly lower than in their control counterparts. Serum vitamin A levels in patients with recurrent, multiple chalazia were significantly lower than in patients with primary, multiple chalazia (P = 0.026) and patients with a recurrent, single chalazion (P = 0.029). In conclusion, chalazion could be one of the ocular presentations of vitamin A deficiency.

  17. A fabricated electro-spun sensor based on Lake Red C pigments doped into PAN (polyacrylonitrile) nano-fibers for electrochemical detection of Aflatoxin B1 in poultry feed and serum samples.

    Science.gov (United States)

    Babakhanian, Arash; Momeneh, Tahereh; Aberoomand-azar, Parviz; Kaki, Samineh; Torki, Mehran; Hossein Kiaie, Seyed; Sadeghi, Ehsan; Dabirian, Farzad

    2015-11-21

    The aim of this work was to fabricate a novel nano-fiber modified electrode, involving Lake Red C (LRC) pigments doped into electrospun polyacrylonitrile (PAN) fibrous films. Cyclic voltammetry (CV), scanning electron microscopy (SEM), electrochemical impedance spectroscopy (EIS) and differential pulse voltammetry (DPV) techniques were used for electrochemical and morphological characterization of the composite fibers. This sensor responds to Aflatoxin B1 (AFB1) over the concentration range of 40-120 nM with high accuracy and precision in analysis. The modified electrode exhibited an excellent electrocatalytic ability (α = 0.42, log K(s) = 4.21 s(-1), and Γ = 1.49 × 10(-5) mmol cm(-2)) for reduction of AFB1 at the optimum pH of 6 and working potential of -0.75 V (vs. SCE). The common substances accompanying AFB1 had no serious interferences on the response of the modified electrode to AFB1. The modified electrode indicated reproducible behavior and a high level stability during the experiments, making it particularly suitable for the analytical determination of AFB1 in poultry feed and serum samples.

  18. Ratiometric Phosphorescent Probe for Thallium in Serum, Water, and Soil Samples Based on Long-Lived, Spectrally Resolved, Mn-Doped ZnSe Quantum Dots and Carbon Dots.

    Science.gov (United States)

    Lu, Xiaomei; Zhang, Jinyi; Xie, Ya-Ni; Zhang, Xinfeng; Jiang, Xiaoming; Hou, Xiandeng; Wu, Peng

    2018-02-20

    Thallium (Tl) is an extremely toxic heavy metal and exists in very low concentrations in the environment, but its sensing is largely underexplored as compared to its neighboring elements in the periodic table (especially mercury and lead). In this work, we developed a ratiometric phosphorescent nanoprobe for thallium detection based on Mn-doped ZnSe quantum dots (QDs) and water-soluble carbon dots (C-dots). Upon excitation with 360 nm, Mn-doped ZnSe QDs and C-dots can emit long-lived and spectrally resolved phosphorescence at 580 and 440 nm, respectively. In the presence of thallium, the phosphorescence emission from Mn-doped ZnSe QDs could be selectively quenched, while that from C-dots retained unchanged. Therefore, a ratiometric phosphorescent probe was thus developed, which can eliminate the potential influence from both background fluorescence and other analyte-independent external environment factors. Several other heavy metal ions caused interferences to thallium detection but could be efficiently masked with EDTA. The proposed method offered a detection limit of 1 μg/L, which is among the most sensitive probes ever reported. Successful application of this method for thallium detection in biological serum as well as in environmental water and soil samples was demonstrated.

  19. Automated extraction of lysergic acid diethylamide (LSD) and N-demethyl-LSD from blood, serum, plasma, and urine samples using the Zymark RapidTrace with LC/MS/MS confirmation.

    Science.gov (United States)

    de Kanel, J; Vickery, W E; Waldner, B; Monahan, R M; Diamond, F X

    1998-05-01

    A forensic procedure for the quantitative confirmation of lysergic acid diethylamide (LSD) and the qualitative confirmation of its metabolite, N-demethyl-LSD, in blood, serum, plasma, and urine samples is presented. The Zymark RapidTrace was used to perform fully automated solid-phase extractions of all specimen types. After extract evaporation, confirmations were performed using liquid chromatography (LC) followed by positive electrospray ionization (ESI+) mass spectrometry/mass spectrometry (MS/MS) without derivatization. Quantitation of LSD was accomplished using LSD-d3 as an internal standard. The limit of quantitation (LOQ) for LSD was 0.05 ng/mL. The limit of detection (LOD) for both LSD and N-demethyl-LSD was 0.025 ng/mL. The recovery of LSD was greater than 95% at levels of 0.1 ng/mL and 2.0 ng/mL. For LSD at 1.0 ng/mL, the within-run and between-run (different day) relative standard deviation (RSD) was 2.2% and 4.4%, respectively.

  20. Thermal transfer and apparent-dose distributions in poorly bleached mortar samples: Results from single grains and small aliquots of quartz

    DEFF Research Database (Denmark)

    Jain, M.; Thomsen, Kristina Jørkov; Bøtter-Jensen, L.

    2004-01-01

    -300 mum and compare the dose-distributions obtained from small aliquots and single-grain procedures. A comparison of three different methods viz. (a) first 5%, (b) probability plot and (c) comparison of internal and external uncertainties, is made for equivalent dose estimation. The results have......;, this process releases all the prior trapped charge and simultaneously sensitises the quartz. Unfortunately unheated materials such as mortar and concrete are more common in industrial sites and particularly in nuclear installations. These materials are usually exposed to daylight during quarrying...... and construction, but in general this exposure is insufficient to completely empty (bleach) any geological trapped charge. This leads to a distribution of apparent doses in the sample at the time of construction with only some (if any) grains exposed to sufficient light to be considered well bleached for OSL...

  1. Ultra-Trace Determination of Copper and Silver in Environmental Samples by Using Ionic Liquid-Based Single Drop Microextraction-Electrothermal Atomic Absorption Spectrometry

    Directory of Open Access Journals (Sweden)

    J. Abolhasani

    2013-11-01

    Full Text Available A sensitive, selective and effective ionic liquid-based single drop microextraction technique wasdeveloped by using ionic liquid, 1-hexyl-3-methylimidazolium hexafluorophosphate, C6MIMPF6, coupledwith electrothermal atomic absorption spectrometry (ETAAS for the determination of copper and silver inenvironmental samples. Dithizone was used as chelating agent. Several factors that influence themicroextraction efficiency and ETAAS signal, such as pH, dithizone concentration, extraction time, amounts ofionic liquid, stirring rate, pyrolysis and atomization temperature were investigated and the microextractionconditions were established. In the optimum experimental conditions, the detection limits (3 s of the methodwere 4 and 8 ng L-1 and corresponding relative standard deviations (0.1 μg L-1, n = 6 were 4.2% and 4.8% forAg and Cu, respectively. The developed method was validated by analysis of a certified reference material andapplied to the determination of silver and copper.

  2. Capillary electrophoresis coupled to evaporative light scattering detection for direct determination of underivatized amino acids: application to tea samples using carboxyled single-walled carbon nanotubes for sample preparation.

    Science.gov (United States)

    Bouri, Mohamed; Salghi, Rachid; Zougagh, Mohammed; Ríos, Angel

    2013-09-01

    An improved and efficient method for the determination of underivatized amino acids based on the use of CE coupled to evaporative light scattering detector (ELSD), involving carbon nanotubes, was successfully developed. Carboxyled single-walled carbon nanotubes were used for the first time to perform the clean-up of the analyzed samples, which were afterwards analyzed by CE-ELSD. White tea samples were used to demonstrate the usefulness of the CE-ELSD coupled methodology. A suitable interface, based on a triple tube design sprayer, was developed and successfully used for coupling both instruments. Parameters affecting the separation and determination, including the elimination of interferences, were studied and properly optimized. Under the optimized conditions good resolution was achieved for the separation of seven amino acids. The precision of the method, expressed as RSD, was found within the 3.5-5.3% range. The LOD obtained for the proposed method were in the 1.2-2.1 pg range and the LOQ, were in the 2.0-11.5 pg range, with injection pressure of 5 KPa for 20 s (15.3 nL). This method is simple, rapid, and selective compared with other conventional techniques. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Fluorescent dye imaging of the volume sampled by single well forced-gradient tracer tests evaluated in a laboratory-scale aquifer physical model.

    Science.gov (United States)

    Barns, Gareth L; Wilson, Ryan D; Thornton, Steven F

    2012-02-01

    This study presents a new method to visualise forced-gradient tracer tests in 2-D using a laboratory-scale aquifer physical model. Experiments were designed to investigate the volume of aquifer sampled in vertical dipole flow tracer tests (DFTT) and push-pull tests (PPT), using a miniature monitoring well and straddle packer arrangement equipped with solute injection and recovery chambers. These tests have previously been used to estimate bulk aquifer hydraulic and transport properties for the evaluation of natural attenuation and other remediation approaches. Experiments were performed in a silica glass bead-filled box, using a fluorescent tracer (fluorescein) to deduce conservative solute transport paths. Digital images of fluorescein transport were captured under ultraviolet light and processed to analyse tracer plume geometry and obtain point-concentration breakthrough histories. Inorganic anion mixtures were also used to obtain conventional tracer breakthrough histories. Concentration data from the conservative tracer breakthrough curves was compared with the digital images and a well characterised numerical model. The results show that the peak tracer breakthrough response in dipole flow tracer tests samples a zone of aquifer close to the well screen, while the sampling volume of push-pull tests is limited by the length of the straddle packers used. The effective sampling volume of these single well forced-gradient tests in isotropic conditions can be estimated with simple equations. The experimental approach offers the opportunity to evaluate under controlled conditions the theoretical basis, design and performance of DFTTs and PPTs in porous media in relation to measured flow and transport properties. Copyright © 2011 Elsevier B.V. All rights reserved.

  4. Integration of GC-MSD and ER-Calux® assay into a single protocol for determining steroid estrogens in environmental samples.

    Science.gov (United States)

    Avberšek, Miha; Žegura, Bojana; Filipič, Metka; Heath, Ester

    2011-11-01

    There are many published studies that use either chemical or biological methods to investigate steroid estrogens in the aquatic environment, but rarer are those that combine both. In this study, gas chromatography with mass selective detection (GC-MSD) and the ER-Calux(®) estrogenicity assay were integrated into a single protocol for simultaneous determination of natural (estrone--E1, 17β-estradiol--E2, estriol--E3) and synthetic (17α-ethinylestradiol--EE2) steroid estrogens concentrations and the total estrogenic potential of environmental samples. For integration purposes, several solvents were investigated and the commonly used dimethyl sulphoxide (DMSO) in the ER-Calux(®) assay was replaced by ethyl acetate, which is more compatible with gas chromatography and enables the same sample to be analysed by both GC-MSD and the ER-Calux(®) assay. The integrated protocol was initially tested using a standard mixture of estrogens. The results for pure standards showed that the estrogenicity calculated on the basis of GC-MSD and the ER-Calux(®) assay exhibited good correlation (r(2)=0.96; α=0.94). The result remained the same when spiked waste water extracts were tested (r(2)=0.92, α=1.02). When applied to real waste water influent and effluent samples the results proved (r(2)=0.93; α=0.99) the applicability of the protocol. The main advantages of this newly developed protocol are simple sample handling for both methods, and reduced material consumption and labour. In addition, it can be applied as either a complete or sequential analysis where the ER-Calux(®) assay is used as a pre-screening method prior to the chemical analysis. Copyright © 2011 Elsevier B.V. All rights reserved.

  5. Fluorescent dye imaging of the volume sampled by single well forced-gradient tracer tests evaluated in a laboratory-scale aquifer physical model

    Science.gov (United States)

    Barns, Gareth L.; Wilson, Ryan D.; Thornton, Steven F.

    2012-02-01

    This study presents a new method to visualise forced-gradient tracer tests in 2-D using a laboratory-scale aquifer physical model. Experiments were designed to investigate the volume of aquifer sampled in vertical dipole flow tracer tests (DFTT) and push-pull tests (PPT), using a miniature monitoring well and straddle packer arrangement equipped with solute injection and recovery chambers. These tests have previously been used to estimate bulk aquifer hydraulic and transport properties for the evaluation of natural attenuation and other remediation approaches. Experiments were performed in a silica glass bead-filled box, using a fluorescent tracer (fluorescein) to deduce conservative solute transport paths. Digital images of fluorescein transport were captured under ultraviolet light and processed to analyse tracer plume geometry and obtain point-concentration breakthrough histories. Inorganic anion mixtures were also used to obtain conventional tracer breakthrough histories. Concentration data from the conservative tracer breakthrough curves was compared with the digital images and a well characterised numerical model. The results show that the peak tracer breakthrough response in dipole flow tracer tests samples a zone of aquifer close to the well screen, while the sampling volume of push-pull tests is limited by the length of the straddle packers used. The effective sampling volume of these single well forced-gradient tests in isotropic conditions can be estimated with simple equations. The experimental approach offers the opportunity to evaluate under controlled conditions the theoretical basis, design and performance of DFTTs and PPTs in porous media in relation to measured flow and transport properties. DFTT = Dipole Flow Tracer Test, PPT = Push Pull Tracer Test.

  6. Amostragem por larva-única na vigilância de Aedes aegypti Single-larva sampling for Aedes aegypti surveillance

    Directory of Open Access Journals (Sweden)

    José Eduardo Bracco

    1995-04-01

    Full Text Available Com a finalidade de testar a metodologia de amostragem por larva-única na vigilância entomológica do Aedes aegypti, foram pesquisados domicílios do Município de Araraquara, SP (Brasil. Nos criadouros que continham larvas de Aedes uma delas foi coletada. Como controle, após a coleta da larva-única, todas as larvas foram coletadas para identificação posterior. Esse processo foi repetido no laboratório. Dos 447 domicílios visitados, apenas 12 foram considerados positivos e 20 criadouros foram identificados; destes, 13 continham larvas de Aedes; 5, larvas de Aedes e Culex e 2, larvas de Culex. Os resultados mostram o reconhecimento correto, no campo, de todos os criadouros, evidenciando que o método poderia ser utilizado na vigilância entomológica de municípios sem infestação domiciliar ou infestados apenas com uma única espécie de Aedes.Buildings in Araraquara city, Southeastern Brazil, were searched during a year for the presence of Aedes larvae using single larva sampling in order to check the single-larva methodology. In those breeding places in wich Aedes larvae were found, one of them was collected. As a control, after the single larva had been collected, all the larvae from the breeding place were collected for later identification. This process was repeated in the laboratory. Of the 447 domiciles searched, 12 were considered positive and 20 breeding places were found. Of the breeding places, 13 contained Aedes larvae, 5 both Aedes and Culex larvae and 2 Culex larvae only. The results show that all the breeding places in the field were properly recognited showing the method may be used for Aedes surveillance in cities infested with one species only or without any domiciliary infestation.

  7. The structural and magnetic properties of CsxFe2-ySe2 as determined by x ray and neutron scattering of powder and single crystal samples

    Science.gov (United States)

    Taddei, Keith; Chmaissem, Omar; Sturza, Mihai; Avci, Sevda; Claus, Helmut; Kanatzids, Mercouri; Rosenkranz, Stephan; Osborn, Ray

    2014-03-01

    The AxFe2-ySe2 family of iron selenides (A = K, Rb and Cs) has proven an intricate system for the study of unconventional superconductivity, exhibiting high temperature superconductivity (~ 30 K) and a complex structural phase transition into a biphasic state coupled with a high temperature magnetic transition (~ 500 K). While isostructural to the 122 arsenides, significant structural differences are identified. In the selenides, iron vacancies in the tetrahedral FeSe layers become ordered below a high temperature structural transition defining a main phase √ 5 × √ 5 superstructure. Coexistent with the main phase, a secondary phase of a previously contested structure is observed and it is in this biphasic state that superconductivity arises at ~ 30 K. Both powder and single crystal samples show similar phase separation and coexistence. In this talk, I will discuss structural results and lattice parameter evolution obtained from neutron powder diffraction as well as single crystal x-ray diffraction with an emphasis on a novel magnetic structural model, the identification of the secondary phase, and the nature of coincidence of the magnetic, structural and secondary phase transitions.

  8. Determination of {sup 236}U in environmental samples by single extraction chromatography coupled to triple-quadrupole inductively coupled plasma-mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Guosheng [Department of Radiation Chemistry, Institute of Radiation Emergency Medicine, Hirosaki University, 66-1 Hon-cho, Hirosaki, Aomori, 036-8564 (Japan); Division of Nuclear Technology and Applications, Institute of High Energy Physics, Chinese Academy of Sciences (China); Beijing Engineering Research Center of Radiographic Techniques and Equipment, Beijing, 100049 (China); Tazoe, Hirofumi [Department of Radiation Chemistry, Institute of Radiation Emergency Medicine, Hirosaki University, 66-1 Hon-cho, Hirosaki, Aomori, 036-8564 (Japan); Yamada, Masatoshi, E-mail: myamada@hirosaki-u.ac.jp [Department of Radiation Chemistry, Institute of Radiation Emergency Medicine, Hirosaki University, 66-1 Hon-cho, Hirosaki, Aomori, 036-8564 (Japan)

    2016-11-09

    In order to measure trace {sup 236}U and {sup 236}U/{sup 238}U in environmental samples with a high matrix effect, a novel and simple method was developed that makes the digestion and purification procedures compatible with advanced triple-quadrupole inductively coupled plasma-mass spectrometry. A total dissolution of sample with HF + HNO{sub 3} + HClO{sub 4} was followed by chromatographic separation with a single resin column containing normal type DGA resin (N,N,N′,N’-tetra-n-octyldiglycolamide) as the extractant system. The analytical accuracy and precision of {sup 236}U/{sup 238}U ratios, measured as {sup 236}U{sup 16}O{sup +}/{sup 238}U{sup 16}O{sup +}, were examined by using the reference materials IAEA-135, IAEA-385, IAEA-447, and JSAC 0471. The low method detection limit (3.50 × 10{sup −6} Bq kg{sup −1}) makes it possible to perform routine monitoring of environmental {sup 236}U due to global fallout combined with the Fukushima Daiichi Nuclear Power Plant accident fallout (>10{sup −5} Bq kg{sup −1}). Finally, the developed method was successfully applied to measure {sup 236}U/{sup 238}U ratios and {sup 236}U activities in soil samples contaminated by the accident. The low {sup 236}U/{sup 238}U atom ratios ((1.50–13.5) × 10{sup −8}) and {sup 236}U activities ((2.25–14.1) × 10{sup −2} mBq kg{sup −1}) indicate {sup 236}U contamination was mainly derived from global fallout in the examined samples. - Highlights: • A simple {sup 236}U/{sup 238}U analytical method has been developed. • The separation required just one DGA column chromatography. • {sup 236}U/{sup 238}U atom ratios in soil were measured by ICP-MS/MS. • {sup 236}U/{sup 238}U atom ratios of (1.50–13.5) × 10{sup −8} were observed in Japanese samples. • {sup 236}U activities of (2.25–14.1) × 10{sup −2} mBq kg{sup −1} were found in Japanese samples.

  9. Photothermal desorption of single-walled carbon nanotubes and coconut shell-activated carbons using a continuous light source for application in air sampling.

    Science.gov (United States)

    Floyd, Evan L; Sapag, Karim; Oh, Jonghwa; Lungu, Claudiu T

    2014-08-01

    Many techniques exist to measure airborne volatile organic compounds (VOCs), each with differing advantages; sorbent sampling is compact, versatile, has good sample stability, and is the preferred technique for collecting VOCs for hygienists. Development of a desorption technique that allows multiple analyses per sample (similar to chemical desorption) with enhanced sensitivity (similar to thermal desorption) would be helpful to field hygienists. In this study, activated carbon (AC) and single-walled carbon nanotubes (SWNT) were preloaded with toluene vapor and partially desorbed with light using a common 12-V DC, 50-W incandescent/halogen lamp. A series of experimental chamber configurations were explored starting with a 500-ml chamber under static conditions, then with low ventilation and high ventilation, finally a 75-ml high ventilation chamber was evaluated. When preloaded with toluene and irradiated at the highest lamp setting for 4min, AC desorbed 13.9, 18.5, 23.8, and 45.9% of the loaded VOC mass, in each chamber configuration, respectively; SWNT desorbed 25.2, 24.3, 37.4, and 70.5% of the loaded VOC mass, respectively. SWNT desorption was significantly greater than AC in all test conditions (P = 0.02-<0.0001) demonstrating a substantial difference in sorbent performance. When loaded with 0.435mg toluene and desorbed at the highest lamp setting for 4min in the final chamber design, the mean desorption for AC was 45.8% (39.7, 52.0) and SWNT was 72.6% (68.8, 76.4) (mean represented in terms of 95% confidence interval). All desorption measurements were obtained using a field grade photoionization detector; this demonstrates the potential of using this technique to perform infield prescreening of VOC samples for immediate exposure feedback and in the analytical lab to introduce sample to a gas chromatograph for detailed analysis of the sample. © The Author 2014. Published by Oxford University Press on behalf of the British Occupational Hygiene Society.

  10. A Comparative Study of Single-pulse and Double-pulse Laser-Induced Breakdown Spectroscopy with Uranium-containing Samples.

    Science.gov (United States)

    Skrodzki, Patrick J; Becker, Jason R; Diwakar, Prasoon K; Harilal, Sivanandan S; Hassanein, Ahmed

    2016-03-01

    Laser-induced breakdown spectroscopy (LIBS) holds potential advantages in special nuclear material (SNM) sensing and nuclear forensics, which require rapid analysis, minimal sample preparation, and stand-off distance capability. SNM, such as U, however, result in crowded emission spectra with LIBS, and characteristic emission lines are challenging to discern. It is well-known that double-pulse LIBS (DPLIBS) improves the signal intensity for analytes over conventional single-pulse LIBS (SPLIBS). This study investigates the U signal in a glass matrix using DPLIBS and compares it to signal obtained using SPLIBS. Double-pulse LIBS involves sequential firing of a 1.06 µm Nd:YAG pre-pulse and 10.6 µm TEA CO2 heating pulse in a near collinear geometry. Optimization of experimental parameters including inter-pulse delay and energy follows identification of characteristic lines for the bulk analyte Ca and the minor constituent analyte U for both DPLIBS and SPLIBS. Spatial and temporal coupling of the two pulses in the proposed DPLIBS technique yields improvements in analytical merits with a negligible increase in damage to the sample compared to SPLIBS. Subsequently, the study discusses optimum plasma emission conditions of U lines and relative figures of merit in both SPLIBS and DPLIBS. Investigation into plasma characteristics also addresses plausible mechanisms related to the observed U analyte signal variation between SPLIBS and DPLIBS. © The Author(s) 2016.

  11. Environmental Stress Testing of the Single Sample Cylinder: A Proven Consensus Standard for Internal Gas Analysis (IGA) or Residual Gas Analysis (RGA)

    Science.gov (United States)

    Schuessler, Philipp WH

    2010-01-01

    In August 2008, Schuessler Consulting was contracted by NASA GSFC in support of the NASA Electronic Parts and Packaging (NEPP) program to perform two separate studies on moisture laden air in a stainless steel cylinder that had been designed to become a consensus standard for Test Method 1018. This Test Method was originally released for hybrids under Mil. Std. 883 but was quickly utilized on other microelectronic devices under the auspice of Mil. Std. 750. The cylinder had subsequently been fabricated for the 750 community. It was back-filled with moist air and subsequently analyzed over a period of time under a previous NASA contract. It had been shown that moisture in the 4000 - 5000 ppm range could be analyzed rather precisely with a mass spectrometer, commonly referred to as a Residual Gas Analyzer (RGA). The scope of this study was to ascertain if the composition and precision varied as a function of thermal shock at sub-zero temperatures and whether there was consensus when the standard was submitted to other RGA units. It was demonstrated and published that the consensus standard would yield precise RGA data for moisture within +/- 1% when optimized for a given RGA unit. It has been subsequently shown in this study at Oneida Research Services, that sub-zero storage did not affect that precision when a well-defined protocol for the analysis was followed. The consensus standard was taken to a second facility for analysis where it was found that moisture adsorption on the transfer lines caused precision to drop to +/- 12%. The Single Sample Cylinder (SSC) is a one liter stainless steel cylinder with associated sampling valves and has considerable weight and volume. But this considerable size allows for approximately 300 gas samples of the same composition to be delivered to any RGA unit. Lastly, a smaller cylinder, approximately 75 cc, of a second consensus standard was fabricated and tested with a different mix of fixed gases where moisture was kept in the

  12. Estimating the effective number of breeders from single parr samples for conservation monitoring of wild populations of Atlantic salmon Salmo salar.

    Science.gov (United States)

    Bacles, C F E; Bouchard, C; Lange, F; Manicki, A; Tentelier, C; Lepais, O

    2018-03-01

    This study assesses whether the effective number of breeders (N b ) can be estimated using a time and cost-effective protocol using genetic sibship reconstruction from a single sample of young-of-the-year (YOY) for the purposes of Atlantic salmon Salmo salar population monitoring. N b was estimated for 10 consecutive reproductive seasons for S. salar in the River Nivelle, a small population located at the rear-edge of the species distribution area in France, chronically under its conservation limit and subjected to anthropogenic and environmental changes. Subsampling of real and simulated data showed that accurate estimates of N b can be obtained from YOY genotypes, collected at moderate random sampling intensity, achievable using routine juvenile electrofishing protocols. Spatial bias and time elapsed since spawning were found to affect estimates, which must be accounted for in sampling designs. N b estimated in autumn for S. salar in the River Nivelle was low and variable across years from 23 (95% C.I. 14-41) to 75 (53-101) and was not statistically correlated with the estimated number of returning adults, but it was positively correlated with the estimated number of YOY at age 9 months. N b was found to be lower for intermediate levels of redd aggregation, suggesting that the strength of the competition between males to access females affects reproductive success variance depending on redd spatial configuration. Thus, environmental factors such as habitat availability and quality for spawning and YOY development predominate over demographic ones (number of returning adults) in driving long-term population viability for S. salar in the River Nivelle. This study showcases N b as an integrated parameter, encompassing demographic and ecological information about a reproductive event, relevant to the assessment of both short-term effects of management practices and long-term population conservation status. © 2018 The Fisheries Society of the British Isles.

  13. Spectroelectrochemical Sensing Based on Multimode Selectivity simultaneously Achievable in a Single Device. 11. Design and Evaluation of a Small Portable Sensor for the Determination of Ferrocyanide in Hanford Waste Samples

    International Nuclear Information System (INIS)

    Stegemiller, Michael L.; Heineman, William R.; Seliskar, Carl J.; Ridgway, Thomas H.; Bryan, Samuel A.; Hubler, Timothy L.; Sell, Richard L.

    2003-01-01

    Spectroelectrochemical sensing based on multimode selectivity simultaneously achievable in a single device. 11. Design and evaluation of a small portable sensor for the determination of ferrocyanide in Hanford waste samples

  14. A Single-Use, In Vitro Biosensor for the Detection of T-Tau Protein, A Biomarker of Neuro-Degenerative Disorders, in PBS and Human Serum Using Differential Pulse Voltammetry (DPV).

    Science.gov (United States)

    Dai, Yifan; Molazemhosseini, Alireza; Liu, Chung Chiun

    2017-02-19

    A single-use, in vitro biosensor for the detection of T-Tau protein in phosphate-buffer saline (PBS) and undiluted human serum was designed, manufactured, and tested. Differential pulse voltammetry (DPV) served as the transduction mechanism. This biosensor consisted of three electrodes: working, counter, and reference electrodes fabricated on a PET sheet. Both working and counter electrodes were thin gold film, 10 nm in thickness. Laser ablation technique was used to define the size and structure of the biosensor. The biosensor was produced using cost-effective roll-to-roll process. Self-assembled monolayers (SAM) of 3-mercaptopropionic acid (MPA) were employed to covalently immobilize the anti-T-Tau (T-Tau antibody) on the gold working electrode. A carbodiimide conjugation approach using N-(3-dimethylaminopropyl)-N'-ethylcarbodiimide hydrochloride (EDC) and N-hydroxysuccinimide (NHS) cross-linked anti-T-Tau to the carboxylic groups on one end of the MPA. A T-Tau protein ladder with six isoforms was used in this study. The anti-T-Tau concentration used was 500,000 pg/mL. The T-Tau protein concentration ranged from 1000 pg/mL to 100,000 pg/mL. DPV measurements showed excellent responses, with a good calibration curve. Thus, a practical tool for simple detection of T-Tau protein, a biomarker of neuro-degenerative disorders, has been successfully developed. This tool could also be extended to detect other biomarkers for neuro-degenerative disorders, such as P-Tau protein and β-amyloid 42.

  15. ‘N-of-1-pathways’ unveils personal deregulated mechanisms from a single pair of RNA-Seq samples: towards precision medicine

    Science.gov (United States)

    Gardeux, Vincent; Achour, Ikbel; Li, Jianrong; Maienschein-Cline, Mark; Li, Haiquan; Pesce, Lorenzo; Parinandi, Gurunadh; Bahroos, Neil; Winn, Robert; Foster, Ian; Garcia, Joe G N; Lussier, Yves A

    2014-01-01

    Background The emergence of precision medicine allowed the incorporation of individual molecular data into patient care. Indeed, DNA sequencing predicts somatic mutations in individual patients. However, these genetic features overlook dynamic epigenetic and phenotypic response to therapy. Meanwhile, accurate personal transcriptome interpretation remains an unmet challenge. Further, N-of-1 (single-subject) efficacy trials are increasingly pursued, but are underpowered for molecular marker discovery. Method ‘N-of-1-pathways’ is a global framework relying on three principles: (i) the statistical universe is a single patient; (ii) significance is derived from geneset/biomodules powered by paired samples from the same patient; and (iii) similarity between genesets/biomodules assesses commonality and differences, within-study and cross-studies. Thus, patient gene-level profiles are transformed into deregulated pathways. From RNA-Seq of 55 lung adenocarcinoma patients, N-of-1-pathways predicts the deregulated pathways of each patient. Results Cross-patient N-of-1-pathways obtains comparable results with conventional genesets enrichment analysis (GSEA) and differentially expressed gene (DEG) enrichment, validated in three external evaluations. Moreover, heatmap and star plots highlight both individual and shared mechanisms ranging from molecular to organ-systems levels (eg, DNA repair, signaling, immune response). Patients were ranked based on the similarity of their deregulated mechanisms to those of an independent gold standard, generating unsupervised clusters of diametric extreme survival phenotypes (p=0.03). Conclusions The N-of-1-pathways framework provides a robust statistical and relevant biological interpretation of individual disease-free survival that is often overlooked in conventional cross-patient studies. It enables mechanism-level classifiers with smaller cohorts as well as N-of-1 studies. Software http://lussierlab.org/publications/N-of-1-pathways

  16. Fully automated ionic liquid-based headspace single drop microextraction coupled to GC-MS/MS to determine musk fragrances in environmental water samples.

    Science.gov (United States)

    Vallecillos, Laura; Pocurull, Eva; Borrull, Francesc

    2012-09-15

    A fully automated ionic liquid-based headspace single drop microextraction (IL-HS-SDME) procedure has been developed for the first time to preconcentrate trace amounts of ten musk fragrances extensively used in personal care products (six polycyclic musks, three nitro musks and one polycyclic musk degradation product) from wastewater samples prior to analysis by gas chromatography and ion trap tandem mass spectrometry (GC-IT-MS/MS). Due to the low volatility of the ILs, a large internal diameter liner (3.4 mm i.d.) was used to improve the ILs evaporation. Furthermore, a piece of glass wool was introduced into the liner to avoid the entrance of the ILs in the GC column and a guard column was used to prevent analytical column damages. The main factors influencing the IL-HS-SDME were optimized. For all species, the highest enrichments factors were achieved using 1 μL of 1-octyl-3-methylimidazolium hexafluorophosphate ([OMIM][PF(6)]) ionic liquid exposed in the headspace of 10 mL water samples containing 300 g L(-1) of NaCl and stirred at 750 rpm and 60 °C for 45 min. All compounds were determined by direct injection GC-IT-MS/MS with a chromatographic time of 19 min. Method detection limits were found in the low ng mL(-1) range between 0.010 ng mL(-1) and 0.030 ng mL(-1) depending on the target analytes. Also, under optimized conditions, the method gave good levels of intra-day and inter-day repeatabilities in wastewater samples with relative standard deviations varying between 3% and 6% and 5% and 11%, respectively (n=3, 1 ng mL(-1)). The applicability of the method was tested with different wastewater samples from influent and effluent urban wastewater treatment plants (WWTPs) and one potable treatment plant (PTP). The analysis of influent urban wastewater revealed the presence of galaxolide and tonalide at concentrations of between 2.10 ng mL(-1) and 0.29 ng mL(-1) and 0.32 ng mL(-1) and MQL (Method Quantification Limit), respectively; while the remaining

  17. Serum and follicular fluid organochlorine concentrations among women undergoing assisted reproduction technologies.

    Science.gov (United States)

    Meeker, John D; Missmer, Stacey A; Altshul, Larisa; Vitonis, Allison F; Ryan, Louise; Cramer, Daniel W; Hauser, Russ

    2009-07-14

    Exposure to persistent organic pollutants, including polychlorinated biphenyls (PCBs) and organochlorine pesticides, is widespread among the general population. There is evidence of adverse effects on reproduction and early pregnancy in relation to organochlorine exposure but human studies remain limited. The increased use of assisted reproductive technologies (ART) presents unique opportunities for the assessment of environmental influences on early pregnancy outcomes not otherwise observable in humans, but studies need to be designed to maximize the efficiency of the exposure data collected while minimizing exposure measurement error. The present study was conducted to assess the correlation between concentrations of organochlorines in serum and follicular fluid samples collected from a subset of women undergoing ART in a large study that took place between 1994 and 2003, as well as the temporal reliability of serum organochlorine concentrations among women undergoing multiple ART cycles in the study. PCB congeners (118, 138, 153, and 180), 1,1,1-trichloro-2,2-bis(p-chlorophenyl)ethane (p,p'-DDT), the DDT metabolite p,p'-DDE, hexachlorobenzene (HCB), oxychlordane, trans-nonachlor and mirex were measured in 72 follicular fluid samples and 265 serum samples collected from 110 women. Organochlorine concentrations in paired serum and follicular fluid samples were correlated, with Pearson and Spearman coefficients ranging from 0.60 to 0.92. Serum organochlorine concentrations were two- to three-fold greater than in follicular fluid, and a significant inverse trend was observed in the distribution of follicular fluid:serum ratios with increasing molecular weight of the compound (p-value for trend single serum sample to adequately represent a more biologically relevant dose (concentrations in follicular fluid), as well as exposure levels over time, in epidemiological studies of ART outcomes in relation to organochlorine exposure.