WorldWideScience

Sample records for single node scale

  1. Post place and route design-technology co-optimization for scaling at single-digit nodes with constant ground rules

    Science.gov (United States)

    Mattii, Luca; Milojevic, Dragomir; Debacker, Peter; Berekovic, Mladen; Sherazi, Syed Muhammad Yasser; Chava, Bharani; Bardon, Marie Garcia; Schuddinck, Pieter; Rodopoulos, Dimitrios; Baert, Rogier; Gerousis, Vassilios; Ryckaert, Julien; Raghavan, Praveen

    2018-01-01

    Standard-cell design, technology choices, and place and route (P&R) efficiency are deeply interrelated in CMOS technology nodes below 10 nm, where lower number of tracks cells and higher pin densities pose increasingly challenging problems to the router in terms of congestion and pin accessibility. To evaluate and downselect the best solutions, a holistic design-technology co-optimization approach leveraging state-of-the-art P&R tools is thus necessary. We adopt such an approach using the imec N7 technology platform, with contacted poly pitch of 42 nm and tightest metal pitch of 32 nm, by comparing post P&R area of an IP block for different standard cell configurations, technology options, and cell height. Keeping the technology node and the set of ground rules unchanged, we demonstrate that a careful combination of these solutions can enable area gains of up to 50%, comparable with the area benefits of migrating to another node. We further demonstrate that these area benefits can be achieved at isoperformance with >20% reduced power. As at the end of the CMOS roadmap, conventional scaling enacted through pitch reduction is made more and more challenging by constraints imposed by lithography limits, material resistivity, manufacturability, and ultimately wafer cost, the approach shown herein offers a valid, attractive, and low-cost alternative.

  2. Identifying Controlling Nodes in Neuronal Networks in Different Scales

    Science.gov (United States)

    Tang, Yang; Gao, Huijun; Zou, Wei; Kurths, Jürgen

    2012-01-01

    Recent studies have detected hubs in neuronal networks using degree, betweenness centrality, motif and synchronization and revealed the importance of hubs in their structural and functional roles. In addition, the analysis of complex networks in different scales are widely used in physics community. This can provide detailed insights into the intrinsic properties of networks. In this study, we focus on the identification of controlling regions in cortical networks of cats’ brain in microscopic, mesoscopic and macroscopic scales, based on single-objective evolutionary computation methods. The problem is investigated by considering two measures of controllability separately. The impact of the number of driver nodes on controllability is revealed and the properties of controlling nodes are shown in a statistical way. Our results show that the statistical properties of the controlling nodes display a concave or convex shape with an increase of the allowed number of controlling nodes, revealing a transition in choosing driver nodes from the areas with a large degree to the areas with a low degree. Interestingly, the community Auditory in cats’ brain, which has sparse connections with other communities, plays an important role in controlling the neuronal networks. PMID:22848475

  3. Hybrid single node genetic programming for symbolic regression

    NARCIS (Netherlands)

    Kubalìk, Jiřì; Alibekov, Eduard; Žegklitz, Jan; Babuska, R.; Nguyen, NT; Kowalczyk, R; Filipe, J

    2016-01-01

    This paper presents a first step of our research on designing an effective and efficient GP-based method for symbolic regression. First, we propose three extensions of the standard Single Node GP, namely (1) a selection strategy for choosing nodes to be mutated based on depth and performance of

  4. Biochemical aspects of single-node cuttings of Ricinodendron ...

    African Journals Online (AJOL)

    NEHEMIE

    2013-03-06

    Mar 6, 2013 ... changes, basal single-node leafy cuttings were treated with different .... with local material and providing an internal irradiance of 20 to 32%. ..... higher in rooting cutting during the initiation phase). Phenolics ... Chrysanthemum cuttings as affected by nitrogen supply and cold- storage. Ann. Bot. 85:697-701.

  5. Node-node correlations and transport properties in scale-free networks

    Science.gov (United States)

    Obregon, Bibiana; Guzman, Lev

    2011-03-01

    We study some transport properties of complex networks. We focus our attention on transport properties of scale-free and small-world networks and compare two types of transport: Electric and max-flow cases. In particular, we construct scale-free networks, with a given degree sequence, to estimate the distribution of conductances for different values of assortative/dissortative mixing. For the electric case we find that the distributions of conductances are affect ed by the assortative mixing of the network whereas for the max-flow case, the distributions almost do not show changes when node-node correlations are altered. Finally, we compare local and global transport in terms of the average conductance for the small-world (Watts-Strogatz) model

  6. Persistent Memory in Single Node Delay-Coupled Reservoir Computing.

    Directory of Open Access Journals (Sweden)

    André David Kovac

    Full Text Available Delays are ubiquitous in biological systems, ranging from genetic regulatory networks and synaptic conductances, to predator/pray population interactions. The evidence is mounting, not only to the presence of delays as physical constraints in signal propagation speed, but also to their functional role in providing dynamical diversity to the systems that comprise them. The latter observation in biological systems inspired the recent development of a computational architecture that harnesses this dynamical diversity, by delay-coupling a single nonlinear element to itself. This architecture is a particular realization of Reservoir Computing, where stimuli are injected into the system in time rather than in space as is the case with classical recurrent neural network realizations. This architecture also exhibits an internal memory which fades in time, an important prerequisite to the functioning of any reservoir computing device. However, fading memory is also a limitation to any computation that requires persistent storage. In order to overcome this limitation, the current work introduces an extended version to the single node Delay-Coupled Reservoir, that is based on trained linear feedback. We show by numerical simulations that adding task-specific linear feedback to the single node Delay-Coupled Reservoir extends the class of solvable tasks to those that require nonfading memory. We demonstrate, through several case studies, the ability of the extended system to carry out complex nonlinear computations that depend on past information, whereas the computational power of the system with fading memory alone quickly deteriorates. Our findings provide the theoretical basis for future physical realizations of a biologically-inspired ultrafast computing device with extended functionality.

  7. Persistent Memory in Single Node Delay-Coupled Reservoir Computing.

    Science.gov (United States)

    Kovac, André David; Koall, Maximilian; Pipa, Gordon; Toutounji, Hazem

    2016-01-01

    Delays are ubiquitous in biological systems, ranging from genetic regulatory networks and synaptic conductances, to predator/pray population interactions. The evidence is mounting, not only to the presence of delays as physical constraints in signal propagation speed, but also to their functional role in providing dynamical diversity to the systems that comprise them. The latter observation in biological systems inspired the recent development of a computational architecture that harnesses this dynamical diversity, by delay-coupling a single nonlinear element to itself. This architecture is a particular realization of Reservoir Computing, where stimuli are injected into the system in time rather than in space as is the case with classical recurrent neural network realizations. This architecture also exhibits an internal memory which fades in time, an important prerequisite to the functioning of any reservoir computing device. However, fading memory is also a limitation to any computation that requires persistent storage. In order to overcome this limitation, the current work introduces an extended version to the single node Delay-Coupled Reservoir, that is based on trained linear feedback. We show by numerical simulations that adding task-specific linear feedback to the single node Delay-Coupled Reservoir extends the class of solvable tasks to those that require nonfading memory. We demonstrate, through several case studies, the ability of the extended system to carry out complex nonlinear computations that depend on past information, whereas the computational power of the system with fading memory alone quickly deteriorates. Our findings provide the theoretical basis for future physical realizations of a biologically-inspired ultrafast computing device with extended functionality.

  8. Ultra-Low Power Memory Design in Scaled Technology Nodes

    DEFF Research Database (Denmark)

    Zeinali, Behzad

    that the proposed SRAM reduces access time and leakage current by 40% and 20%, respectively, compared to the standard 8T-SRAM cell without any degradation in read and write margins. The second solution is an asymmetric Schottky barrier device, which can mitigate the read–write conflict of the 6T-SRAM cell in scaled...... technology nodes i.e. sub-50 nm. The 6T-SRAM designed based on the proposed device shows 18% leakage reduction and 54%, 6.6% and 3.1X improvement in read margin, write margin and write time, respectively, compared to the conventional 6T-SRAM cell. To address the standby power issue of SRAMs in scaled...... technology nodes, this thesis also investigates emerging non-volatile spintronics memories. In this respect, STT-MRAMs and SOT-MRAMs are studied and their design challenges are explored. To improve the read performance of STT-MRAMs, a novel non-destructive self-reference sensing scheme is proposed enabling...

  9. Large Scale Simulation Platform for NODES Validation Study

    Energy Technology Data Exchange (ETDEWEB)

    Sotorrio, P. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Qin, Y. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Min, L. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2017-04-27

    This report summarizes the Large Scale (LS) simulation platform created for the Eaton NODES project. The simulation environment consists of both wholesale market simulator and distribution simulator and includes the CAISO wholesale market model and a PG&E footprint of 25-75 feeders to validate the scalability under a scenario of 33% RPS in California with additional 17% of DERS coming from distribution and customers. The simulator can generate hourly unit commitment, 5-minute economic dispatch, and 4-second AGC regulation signals. The simulator is also capable of simulating greater than 10k individual controllable devices. Simulated DERs include water heaters, EVs, residential and light commercial HVAC/buildings, and residential-level battery storage. Feeder-level voltage regulators and capacitor banks are also simulated for feeder-level real and reactive power management and Vol/Var control.

  10. Vascularity and grey-scale sonographic features of normal cervical lymph nodes: variations with nodal size

    International Nuclear Information System (INIS)

    Ying, Michael; Ahuja, Anil; Brook, Fiona; Metreweli, Constantine

    2001-01-01

    AIM: This study was undertaken to investigate variations in the vascularity and grey-scale sonographic features of cervical lymph nodes with their size. MATERIALS AND METHODS: High resolution grey-scale sonography and power Doppler sonography were performed in 1133 cervical nodes in 109 volunteers who had a sonographic examination of the neck. Standardized parameters were used in power Doppler sonography. RESULTS: About 90% of lymph nodes with a maximum transverse diameter greater than 5 mm showed vascularity and an echogenic hilus. Smaller nodes were less likely to show vascularity and an echogenic hilus. As the size of the lymph nodes increased, the intranodal blood flow velocity increased significantly (P 0.05). CONCLUSIONS: The findings provide a baseline for grey-scale and power Doppler sonography of normal cervical lymph nodes. Sonologists will find varying vascularity and grey-scale appearances when encountering nodes of different sizes. Ying, M. et al. (2001)

  11. ASH : Tackling node mobility in large-scale networks

    NARCIS (Netherlands)

    Pruteanu, A.; Dulman, S.

    2012-01-01

    With the increased adoption of technologies likewireless sensor networks by real-world applications, dynamic network topologies are becoming the rule rather than the exception. Node mobility, however, introduces a range of problems (communication interference, path uncertainty, low quality of

  12. Gray-scale contrast-enhanced utrasonography in detecting sentinel lymph nodes: An animal study

    International Nuclear Information System (INIS)

    Wang Yuexiang; Cheng Zhigang; Li Junlai; Tang Jie

    2010-01-01

    Objective: To investigate the usefulness of gray-scale contrast-enhanced ultrasonography for detecting sentinel lymph nodes. Methods: Contrast-enhanced ultrasonography was performed in five normal dogs (four female and one male) after subcutaneous administration of a sonographic contrast agent (Sonovue, Bracco, Milan, Italy). Four distinct regions in each animal were examined. After contrast-enhanced ultrasonography, 0.8 ml of blue dye was injected into the same location as Sonovue and the sentinel lymph nodes were detected by surgical dissection. The findings of contrast-enhanced ultrasonography were compared with those of the blue dye. Results: Twenty-one sentinel lymph nodes were detected by contrast-enhanced ultrasonography while 23 were identified by blue dye with surgical dissection. Compared with the blue dye, the detection rate of enhanced ultrasonography for the sentinel lymph nodes is 91.3% (21/23). Two patterns of enhancement in the sentinel lymph nodes were observed: complete enhancement (5 sentinel lymph nodes) and partial enhancement (16 sentinel lymph nodes). The lymphatic channels were demonstrated as hyperechoic linear structures leading from the injection site and could be readily followed to their sentinel lymph nodes. Histopathologic examination showed proliferation of lymphatic follicles or lymphatic sinus in partial enhanced sentinel lymph nodes while normal lymphatic tissue was demonstrated in completely enhanced sentinel lymph nodes. Conclusions: Sonovue combined with gray-scale contrast-enhanced ultrasonography may provide a feasible method for detecting sentinel lymph nodes.

  13. A chaotic system with a single unstable node

    Energy Technology Data Exchange (ETDEWEB)

    Sprott, J.C. [Department of Physics, University of Wisconsin, Madison, WI 53706 (United States); Jafari, Sajad, E-mail: sajadjafari@aut.ac.ir [Biomedical Engineering Department, Amirkabir University of Technology, Tehran 15875-4413 (Iran, Islamic Republic of); Pham, Viet-Thanh [School of Electronics and Telecommunications, Hanoi University of Science and Technology, 01 Dai Co Viet, Hanoi (Viet Nam); Hosseini, Zahra Sadat [Biomedical Engineering Department, Amirkabir University of Technology, Tehran 15875-4413 (Iran, Islamic Republic of)

    2015-09-25

    This paper describes an unusual example of a three-dimensional dissipative chaotic flow with quadratic nonlinearities in which the only equilibrium is an unstable node. The region of parameter space with bounded solutions is relatively small as is the basin of attraction, which accounts for the difficulty of its discovery. Furthermore, for some values of the parameters, the system has an attracting torus, which is uncommon in three-dimensional systems, and this torus can coexist with a strange attractor or with a limit cycle. The limit cycle and strange attractor exhibit symmetry breaking and attractor merging. All the attractors appear to be hidden in that they cannot be found by starting with initial conditions in the vicinity of the equilibrium, and thus they represent a new type of hidden attractor with important and potentially problematic engineering consequences. - Highlights: • An unusual example of a three-dimensional dissipative chaotic flow is introduced. • In this system the only equilibrium is an unstable node. • For some values of the parameters, the system has an attracting torus. • This torus can coexist with a strange attractor or with a limit cycle. • These properties are uncommon in three-dimensional systems.

  14. [Utility and advantages of single tracer subareolar injection in sentinel lymph node biopsy in breast cancer].

    Science.gov (United States)

    Armas, Fayna; Hernández, María Jesús; Vega, Víctor; Gutiérrez, Isabel; Jiménez, Concepción; Pavcovich, Marta; Báez, Beatriz; Pérez-Correa, Pedro; Núñez, Valentín

    2005-10-01

    Sentinel lymph node (SLN) biopsy is a reliable technique for determining axillary status in patients with early breast cancer. This technique is a minimally invasive procedure that can avoid the use of lymphadenectomy in patients without axillary involvement. We present a validation study of SLN biopsy with subareolar injection of 99mTc-nanocolloids. We studied 100 patients with early breast cancer (T1 and T2) over a 2-year period. All patients underwent deep subareolar-injection of 99mTc-nanocoloid for localization of the sentinel node. Images were obtained and when the sentinel node was seen, it was marked on the skin. All patients underwent tumor excision and radioguided SLN biopsy followed by complete lymphadenectomy. Histopathological analysis of sentinel nodes was performed by hematoxylin-eosin and immunohistochemistry with cytokeratins. The sentinel node was identified in all patients, and a mean of 1.95 sentinel nodes per patient were found. Lymphatic metastases in the sentinel node were found in 44 patients and in 15 of these tumoral spread was also found in the remaining axillary nodes. In the 56 remaining patients the sentinel node was free of metastasis, but in two of them a non-sentinel node was found to be positive (4.5% false negative rate). Sensitivity was 95.7% (44/46), specificity was 100% (54/54), the positive predictive value was 100% and the negative predictive value was 96.4% (54/56). SLN biopsy is an accurate alternative to complete axillary lymph node dissection in patients with early-stage breast cancer. This technique improves the staging of these patients and decreases the morbidity associated with lymphadenectomy. The advantages of subareolar injection are that a single injection site is required, the tumor does not have to be located by other techniques, it allows rapid visualization of the sentinel node and avoids the "shine through phenomenon" when the tumor is located near the axilla.

  15. Solving Minimal Covering Location Problems with Single and Multiple Node Coverage

    Directory of Open Access Journals (Sweden)

    Darko DRAKULIĆ

    2016-12-01

    Full Text Available Location science represents a very attractiveresearch field in combinatorial optimization and it is in expansion in last five decades. The main objective of location problems is determining the best position for facilities in a given set of nodes.Location science includes techniques for modelling problemsand methods for solving them. This paper presents results of solving two types of minimal covering location problems, with single and multiple node coverage, by using CPLEX optimizer and Particle Swarm Optimization method.

  16. A note on Fenchel cuts for the single-node flow problem

    DEFF Research Database (Denmark)

    Klose, Andreas

    The single-node flow problem, which is also known as the single-sink fixed-charge transportation problem, consists in finding a minimum cost flow from a number of nodes to a single sink. The flow cost comprise an amount proportional to the quantity shipped as well as a fixed charge. In this note......, some structural properties of Fenchel cutting planes for this problem are described. Such cuts might then be applied for solving, e.g., fixed-charge transportation problems and more general fixed-charge network flow problems....

  17. Photonic single nonlinear-delay dynamical node for information processing

    Science.gov (United States)

    Ortín, Silvia; San-Martín, Daniel; Pesquera, Luis; Gutiérrez, José Manuel

    2012-06-01

    An electro-optical system with a delay loop based on semiconductor lasers is investigated for information processing by performing numerical simulations. This system can replace a complex network of many nonlinear elements for the implementation of Reservoir Computing. We show that a single nonlinear-delay dynamical system has the basic properties to perform as reservoir: short-term memory and separation property. The computing performance of this system is evaluated for two prediction tasks: Lorenz chaotic time series and nonlinear auto-regressive moving average (NARMA) model. We sweep the parameters of the system to find the best performance. The results achieved for the Lorenz and the NARMA-10 tasks are comparable to those obtained by other machine learning methods.

  18. Mathematical Analysis of Vehicle Delivery Scale of Bike-Sharing Rental Nodes

    Science.gov (United States)

    Zhai, Y.; Liu, J.; Liu, L.

    2018-04-01

    Aiming at the lack of scientific and reasonable judgment of vehicles delivery scale and insufficient optimization of scheduling decision, based on features of the bike-sharing usage, this paper analyses the applicability of the discrete time and state of the Markov chain, and proves its properties to be irreducible, aperiodic and positive recurrent. Based on above analysis, the paper has reached to the conclusion that limit state (steady state) probability of the bike-sharing Markov chain only exists and is independent of the initial probability distribution. Then this paper analyses the difficulty of the transition probability matrix parameter statistics and the linear equations group solution in the traditional solving algorithm of the bike-sharing Markov chain. In order to improve the feasibility, this paper proposes a "virtual two-node vehicle scale solution" algorithm which considered the all the nodes beside the node to be solved as a virtual node, offered the transition probability matrix, steady state linear equations group and the computational methods related to the steady state scale, steady state arrival time and scheduling decision of the node to be solved. Finally, the paper evaluates the rationality and accuracy of the steady state probability of the proposed algorithm by comparing with the traditional algorithm. By solving the steady state scale of the nodes one by one, the proposed algorithm is proved to have strong feasibility because it lowers the level of computational difficulty and reduces the number of statistic, which will help the bike-sharing companies to optimize the scale and scheduling of nodes.

  19. MATHEMATICAL ANALYSIS OF VEHICLE DELIVERY SCALE OF BIKE-SHARING RENTAL NODES

    Directory of Open Access Journals (Sweden)

    Y. Zhai

    2018-04-01

    Full Text Available Aiming at the lack of scientific and reasonable judgment of vehicles delivery scale and insufficient optimization of scheduling decision, based on features of the bike-sharing usage, this paper analyses the applicability of the discrete time and state of the Markov chain, and proves its properties to be irreducible, aperiodic and positive recurrent. Based on above analysis, the paper has reached to the conclusion that limit state (steady state probability of the bike-sharing Markov chain only exists and is independent of the initial probability distribution. Then this paper analyses the difficulty of the transition probability matrix parameter statistics and the linear equations group solution in the traditional solving algorithm of the bike-sharing Markov chain. In order to improve the feasibility, this paper proposes a "virtual two-node vehicle scale solution" algorithm which considered the all the nodes beside the node to be solved as a virtual node, offered the transition probability matrix, steady state linear equations group and the computational methods related to the steady state scale, steady state arrival time and scheduling decision of the node to be solved. Finally, the paper evaluates the rationality and accuracy of the steady state probability of the proposed algorithm by comparing with the traditional algorithm. By solving the steady state scale of the nodes one by one, the proposed algorithm is proved to have strong feasibility because it lowers the level of computational difficulty and reduces the number of statistic, which will help the bike-sharing companies to optimize the scale and scheduling of nodes.

  20. Chemical Transfer (Single Small-Scale) Facility

    Data.gov (United States)

    Federal Laboratory Consortium — Description/History: Chemistry laboratoryThe Chemical Transfer Facility (CTF)  is the only U.S. single small-scale  facility, a single repository for the Army’s...

  1. A Digital Compressed Sensing-Based Energy-Efficient Single-Spot Bluetooth ECG Node.

    Science.gov (United States)

    Luo, Kan; Cai, Zhipeng; Du, Keqin; Zou, Fumin; Zhang, Xiangyu; Li, Jianqing

    2018-01-01

    Energy efficiency is still the obstacle for long-term real-time wireless ECG monitoring. In this paper, a digital compressed sensing- (CS-) based single-spot Bluetooth ECG node is proposed to deal with the challenge in wireless ECG application. A periodic sleep/wake-up scheme and a CS-based compression algorithm are implemented in a node, which consists of ultra-low-power analog front-end, microcontroller, Bluetooth 4.0 communication module, and so forth. The efficiency improvement and the node's specifics are evidenced by the experiments using the ECG signals sampled by the proposed node under daily activities of lay, sit, stand, walk, and run. Under using sparse binary matrix (SBM), block sparse Bayesian learning (BSBL) method, and discrete cosine transform (DCT) basis, all ECG signals were essentially undistorted recovered with root-mean-square differences (PRDs) which are less than 6%. The proposed sleep/wake-up scheme and data compression can reduce the airtime over energy-hungry wireless links, the energy consumption of proposed node is 6.53 mJ, and the energy consumption of radio decreases 77.37%. Moreover, the energy consumption increase caused by CS code execution is negligible, which is 1.3% of the total energy consumption.

  2. BFL: a node and edge betweenness based fast layout algorithm for large scale networks

    Science.gov (United States)

    Hashimoto, Tatsunori B; Nagasaki, Masao; Kojima, Kaname; Miyano, Satoru

    2009-01-01

    Background Network visualization would serve as a useful first step for analysis. However, current graph layout algorithms for biological pathways are insensitive to biologically important information, e.g. subcellular localization, biological node and graph attributes, or/and not available for large scale networks, e.g. more than 10000 elements. Results To overcome these problems, we propose the use of a biologically important graph metric, betweenness, a measure of network flow. This metric is highly correlated with many biological phenomena such as lethality and clusters. We devise a new fast parallel algorithm calculating betweenness to minimize the preprocessing cost. Using this metric, we also invent a node and edge betweenness based fast layout algorithm (BFL). BFL places the high-betweenness nodes to optimal positions and allows the low-betweenness nodes to reach suboptimal positions. Furthermore, BFL reduces the runtime by combining a sequential insertion algorim with betweenness. For a graph with n nodes, this approach reduces the expected runtime of the algorithm to O(n2) when considering edge crossings, and to O(n log n) when considering only density and edge lengths. Conclusion Our BFL algorithm is compared against fast graph layout algorithms and approaches requiring intensive optimizations. For gene networks, we show that our algorithm is faster than all layout algorithms tested while providing readability on par with intensive optimization algorithms. We achieve a 1.4 second runtime for a graph with 4000 nodes and 12000 edges on a standard desktop computer. PMID:19146673

  3. Breast Conserving Surgery and Sentinel Lymph Node Biopsy in Locally Advanced Breast Cancer: Single Center Experience

    Directory of Open Access Journals (Sweden)

    Atakan Sezer

    2011-06-01

    Full Text Available Objective: Patients with locally advanced breast cancer may undergo breast conserving surgery after neoadjuvant chemotherapy. The aim of the study is to evaluate the results of locally advanced breast cancer patients who underwent breast conserving surgery, axillary dissection and sentinel lymph node biopsy in a single center. Material and Methods: 12 patients with locally advanced breast cancer stage IIIA/IIIB were included in the study between 2002-2009. The patients were given anthracycline-based regimen before surgery. Patients underwent breast conserving surgery, axillary dissection, and sentinel lymph node biopsy followed by radiotherapy. Results: There were five patients in stage IIIA, six in stage IIIB, and one in stage IIIC. Patients had received 3-6 regimen of FAC/FEC. Eight had partial and four had complete response. Five positive axilla were detected. The median value of the lymph nodes was 12 (n:8-19. Five patients underwent sentinel lymph node biopsy. The biopsy has failed in one patient and the median value of dissected sentinel node was 3.5 (n:3-4. Locoregional recurrence was not observed in any patients. The mean follow-up of the patients was 29.8 months and median time was 16 (n:2-80 months.Of the 12 patients 10 are alive and 2 were deceased. Conclusion: In selected locally advanced patients, breast conserving surgery and sentinel lymph node biopsy may be applied by a multidisciplinary approach, and excellent success may be achieved in those patients as in early breast cancer patients.

  4. A Digital Compressed Sensing-Based Energy-Efficient Single-Spot Bluetooth ECG Node

    Directory of Open Access Journals (Sweden)

    Kan Luo

    2018-01-01

    Full Text Available Energy efficiency is still the obstacle for long-term real-time wireless ECG monitoring. In this paper, a digital compressed sensing- (CS- based single-spot Bluetooth ECG node is proposed to deal with the challenge in wireless ECG application. A periodic sleep/wake-up scheme and a CS-based compression algorithm are implemented in a node, which consists of ultra-low-power analog front-end, microcontroller, Bluetooth 4.0 communication module, and so forth. The efficiency improvement and the node’s specifics are evidenced by the experiments using the ECG signals sampled by the proposed node under daily activities of lay, sit, stand, walk, and run. Under using sparse binary matrix (SBM, block sparse Bayesian learning (BSBL method, and discrete cosine transform (DCT basis, all ECG signals were essentially undistorted recovered with root-mean-square differences (PRDs which are less than 6%. The proposed sleep/wake-up scheme and data compression can reduce the airtime over energy-hungry wireless links, the energy consumption of proposed node is 6.53 mJ, and the energy consumption of radio decreases 77.37%. Moreover, the energy consumption increase caused by CS code execution is negligible, which is 1.3% of the total energy consumption.

  5. Microdistribution of Thorotrast conglomerates in lymph nodes and radiation exposure of single lymphocytes

    International Nuclear Information System (INIS)

    Steinstraesser, A.; Kemmer, W.; Muth, H.

    1979-01-01

    In Thorotrast patients, chromosome aberrations of lymphocytes from peripheral blood are to be used as a biological dosimeter. To get a significant dose-effect relationship it is necessary to estimate the absorbed dose of a single lymphocyte during its exposure time. In individual cases only average values can be calculated, based on assumptions of special distributions of Thorotrast. At first effects of the size of Thorotrast conglomerates and of their space distribution on the α-radiation dose distribution in their surroundings are described in a model. Then this model is transferred to the real dimensions and the histological structures of lymph nodes bearing Thorotrast. In some individual cases the microdistribution of Thorotrast has been determined in lymph nodes. Some of these results are demonstrated. According to these Thorotrast distributions, calculation of real absorbed dose of lymphocytes are performed. These values can be used for setting up a dose-effect relationship for biological dosimetry

  6. Some scale-free networks could be robust under selective node attacks

    Science.gov (United States)

    Zheng, Bojin; Huang, Dan; Li, Deyi; Chen, Guisheng; Lan, Wenfei

    2011-04-01

    It is a mainstream idea that scale-free network would be fragile under the selective attacks. Internet is a typical scale-free network in the real world, but it never collapses under the selective attacks of computer viruses and hackers. This phenomenon is different from the deduction of the idea above because this idea assumes the same cost to delete an arbitrary node. Hence this paper discusses the behaviors of the scale-free network under the selective node attack with different cost. Through the experiments on five complex networks, we show that the scale-free network is possibly robust under the selective node attacks; furthermore, the more compact the network is, and the larger the average degree is, then the more robust the network is; with the same average degrees, the more compact the network is, the more robust the network is. This result would enrich the theory of the invulnerability of the network, and can be used to build robust social, technological and biological networks, and also has the potential to find the target of drugs.

  7. Implementing IEC 61850-7-420 DER Logical Nodes in a single board

    Directory of Open Access Journals (Sweden)

    Anderson Salazar-Zuluaga

    2017-09-01

    Full Text Available This article discusses the implementation of a variety of logical nodes (LNs of power generation systems based on distributed energy resources (DER in a single board computer (SBC. The SBC allows for the acquisition and encapsulation of analog signals from a photovoltaic (PV array with batteries, based on the IEC 61850-7-420 standard. To achieve this, an SBC integrated with an analog-digital conversion card (ADC enables to read the system’s analog values. The SBC communicates with the ADC card to encapsulate the collected data in the IEC 61850 data object by using the corresponding logical node (LN. An open license library was used to create the IEC 61850 server inside the SBC and the driver of the ADC card manufacturer to communicate both cards. This work aims to develop LNs for DERs in such way that manufacturers of power generation technologies based on renewable sources (such as the sun and/or the wind implement Intelligent Electronic Devices (IED and controllers in accordance with the scope of the standard for these logical nodes (LNs. Finally, the communication testing of the implementation and the results obtained are presented.

  8. A Fast SVD-Hidden-nodes based Extreme Learning Machine for Large-Scale Data Analytics.

    Science.gov (United States)

    Deng, Wan-Yu; Bai, Zuo; Huang, Guang-Bin; Zheng, Qing-Hua

    2016-05-01

    Big dimensional data is a growing trend that is emerging in many real world contexts, extending from web mining, gene expression analysis, protein-protein interaction to high-frequency financial data. Nowadays, there is a growing consensus that the increasing dimensionality poses impeding effects on the performances of classifiers, which is termed as the "peaking phenomenon" in the field of machine intelligence. To address the issue, dimensionality reduction is commonly employed as a preprocessing step on the Big dimensional data before building the classifiers. In this paper, we propose an Extreme Learning Machine (ELM) approach for large-scale data analytic. In contrast to existing approaches, we embed hidden nodes that are designed using singular value decomposition (SVD) into the classical ELM. These SVD nodes in the hidden layer are shown to capture the underlying characteristics of the Big dimensional data well, exhibiting excellent generalization performances. The drawback of using SVD on the entire dataset, however, is the high computational complexity involved. To address this, a fast divide and conquer approximation scheme is introduced to maintain computational tractability on high volume data. The resultant algorithm proposed is labeled here as Fast Singular Value Decomposition-Hidden-nodes based Extreme Learning Machine or FSVD-H-ELM in short. In FSVD-H-ELM, instead of identifying the SVD hidden nodes directly from the entire dataset, SVD hidden nodes are derived from multiple random subsets of data sampled from the original dataset. Comprehensive experiments and comparisons are conducted to assess the FSVD-H-ELM against other state-of-the-art algorithms. The results obtained demonstrated the superior generalization performance and efficiency of the FSVD-H-ELM. Copyright © 2016 Elsevier Ltd. All rights reserved.

  9. Replica Node Detection Using Enhanced Single Hop Detection with Clonal Selection Algorithm in Mobile Wireless Sensor Networks

    Directory of Open Access Journals (Sweden)

    L. S. Sindhuja

    2016-01-01

    Full Text Available Security of Mobile Wireless Sensor Networks is a vital challenge as the sensor nodes are deployed in unattended environment and they are prone to various attacks. One among them is the node replication attack. In this, the physically insecure nodes are acquired by the adversary to clone them by having the same identity of the captured node, and the adversary deploys an unpredictable number of replicas throughout the network. Hence replica node detection is an important challenge in Mobile Wireless Sensor Networks. Various replica node detection techniques have been proposed to detect these replica nodes. These methods incur control overheads and the detection accuracy is low when the replica is selected as a witness node. This paper proposes to solve these issues by enhancing the Single Hop Detection (SHD method using the Clonal Selection algorithm to detect the clones by selecting the appropriate witness nodes. The advantages of the proposed method include (i increase in the detection ratio, (ii decrease in the control overhead, and (iii increase in throughput. The performance of the proposed work is measured using detection ratio, false detection ratio, packet delivery ratio, average delay, control overheads, and throughput. The implementation is done using ns-2 to exhibit the actuality of the proposed work.

  10. Thermal radiation analysis for small satellites with single-node model using techniques of equivalent linearization

    International Nuclear Information System (INIS)

    Anh, N.D.; Hieu, N.N.; Chung, P.N.; Anh, N.T.

    2016-01-01

    Highlights: • Linearization criteria are presented for a single-node model of satellite thermal. • A nonlinear algebraic system for linearization coefficients is obtained. • The temperature evolutions obtained from different methods are explored. • The temperature mean and amplitudes versus the heat capacity are discussed. • The dual criterion approach yields smaller errors than other approximate methods. - Abstract: In this paper, the method of equivalent linearization is extended to the thermal analysis of satellite using both conventional and dual criteria of linearization. These criteria are applied to a differential nonlinear equation of single-node model of the heat transfer of a small satellite in the Low Earth Orbit. A system of nonlinear algebraic equations for linearization coefficients is obtained in the closed form and then solved by the iteration method. The temperature evolution, average values and amplitudes versus the heat capacity obtained by various approaches including Runge–Kutta algorithm, conventional and dual criteria of equivalent linearization, and Grande's approach are compared together. Numerical results reveal that temperature responses obtained from the method of linearization and Grande's approach are quite close to those obtained from the Runge–Kutta method. The dual criterion yields smaller errors than those of the remaining methods when the nonlinearity of the system increases, namely, when the heat capacity varies in the range [1.0, 3.0] × 10 4  J K −1 .

  11. Identifying influential nodes in large-scale directed networks: the role of clustering.

    Science.gov (United States)

    Chen, Duan-Bing; Gao, Hui; Lü, Linyuan; Zhou, Tao

    2013-01-01

    Identifying influential nodes in very large-scale directed networks is a big challenge relevant to disparate applications, such as accelerating information propagation, controlling rumors and diseases, designing search engines, and understanding hierarchical organization of social and biological networks. Known methods range from node centralities, such as degree, closeness and betweenness, to diffusion-based processes, like PageRank and LeaderRank. Some of these methods already take into account the influences of a node's neighbors but do not directly make use of the interactions among it's neighbors. Local clustering is known to have negative impacts on the information spreading. We further show empirically that it also plays a negative role in generating local connections. Inspired by these facts, we propose a local ranking algorithm named ClusterRank, which takes into account not only the number of neighbors and the neighbors' influences, but also the clustering coefficient. Subject to the susceptible-infected-recovered (SIR) spreading model with constant infectivity, experimental results on two directed networks, a social network extracted from delicious.com and a large-scale short-message communication network, demonstrate that the ClusterRank outperforms some benchmark algorithms such as PageRank and LeaderRank. Furthermore, ClusterRank can also be applied to undirected networks where the superiority of ClusterRank is significant compared with degree centrality and k-core decomposition. In addition, ClusterRank, only making use of local information, is much more efficient than global methods: It takes only 191 seconds for a network with about [Formula: see text] nodes, more than 15 times faster than PageRank.

  12. Identifying influential nodes in large-scale directed networks: the role of clustering.

    Directory of Open Access Journals (Sweden)

    Duan-Bing Chen

    Full Text Available Identifying influential nodes in very large-scale directed networks is a big challenge relevant to disparate applications, such as accelerating information propagation, controlling rumors and diseases, designing search engines, and understanding hierarchical organization of social and biological networks. Known methods range from node centralities, such as degree, closeness and betweenness, to diffusion-based processes, like PageRank and LeaderRank. Some of these methods already take into account the influences of a node's neighbors but do not directly make use of the interactions among it's neighbors. Local clustering is known to have negative impacts on the information spreading. We further show empirically that it also plays a negative role in generating local connections. Inspired by these facts, we propose a local ranking algorithm named ClusterRank, which takes into account not only the number of neighbors and the neighbors' influences, but also the clustering coefficient. Subject to the susceptible-infected-recovered (SIR spreading model with constant infectivity, experimental results on two directed networks, a social network extracted from delicious.com and a large-scale short-message communication network, demonstrate that the ClusterRank outperforms some benchmark algorithms such as PageRank and LeaderRank. Furthermore, ClusterRank can also be applied to undirected networks where the superiority of ClusterRank is significant compared with degree centrality and k-core decomposition. In addition, ClusterRank, only making use of local information, is much more efficient than global methods: It takes only 191 seconds for a network with about [Formula: see text] nodes, more than 15 times faster than PageRank.

  13. Exploring Hardware Support For Scaling Irregular Applications on Multi-node Multi-core Architectures

    Energy Technology Data Exchange (ETDEWEB)

    Secchi, Simone; Ceriani, Marco; Tumeo, Antonino; Villa, Oreste; Palermo, Gianluca; Raffo, Luigi

    2013-06-05

    With the recent emergence of large-scale knowledge dis- covery, data mining and social network analysis, irregular applications have gained renewed interest. Classic cache-based high-performance architectures do not provide optimal performances with such kind of workloads, mainly due to the very low spatial and temporal locality of the irregular control and memory access patterns. In this paper, we present a multi-node, multi-core, fine-grained multi-threaded shared-memory system architecture specifically designed for the execution of large-scale irregular applications, and built on top of three pillars, that we believe are fundamental to support these workloads. First, we offer transparent hardware support for Partitioned Global Address Space (PGAS) to provide a large globally-shared address space with no software library overhead. Second, we employ multi-threaded multi-core processing nodes to achieve the necessary latency tolerance required by accessing global memory, which potentially resides in a remote node. Finally, we devise hardware support for inter-thread synchronization on the whole global address space. We first model the performances by using an analytical model that takes into account the main architecture and application characteristics. We describe the hardware design of the proposed cus- tom architectural building blocks that provide support for the above- mentioned three pillars. Finally, we present a limited-scale evaluation of the system on a multi-board FPGA prototype with typical irregular kernels and benchmarks. The experimental evaluation demonstrates the architecture performance scalability for different configurations of the whole system.

  14. How single node dynamics enhances synchronization in neural networks with electrical coupling

    International Nuclear Information System (INIS)

    Bonacini, E.; Burioni, R.; Di Volo, M.; Groppi, M.; Soresina, C.; Vezzani, A.

    2016-01-01

    The stability of the completely synchronous state in neural networks with electrical coupling is analytically investigated applying both the Master Stability Function approach (MSF), developed by Pecora and Carroll (1998), and the Connection Graph Stability method (CGS) proposed by Belykh et al. (2004). The local dynamics is described by Morris–Lecar model for spiking neurons and by Hindmarsh–Rose model in spike, burst, irregular spike and irregular burst regimes. The combined application of both CGS and MSF methods provides an efficient estimate of the synchronization thresholds, namely bounds for the coupling strength ranges in which the synchronous state is stable. In all the considered cases, we observe that high values of coupling strength tend to synchronize the system. Furthermore, we observe a correlation between the single node attractor and the local stability properties given by MSF. The analytical results are compared with numerical simulations on a sample network, with excellent agreement.

  15. Chemoselective single-site Earth-abundant metal catalysts at metal–organic framework nodes

    Energy Technology Data Exchange (ETDEWEB)

    Manna, Kuntal; Ji, Pengfei; Lin, Zekai; Greene, Francis X.; Urban, Ania; Thacker, Nathan C.; Lin, Wenbin (UC)

    2016-08-30

    Earth-abundant metal catalysts are critically needed for sustainable chemical synthesis. Here we report a simple, cheap and effective strategy of producing novel earth-abundant metal catalysts at metal–organic framework (MOF) nodes for broad-scope organic transformations. The straightforward metalation of MOF secondary building units (SBUs) with cobalt and iron salts affords highly active and reusable single-site solid catalysts for a range of organic reactions, including chemoselective borylation, silylation and amination of benzylic C–H bonds, as well as hydrogenation and hydroboration of alkenes and ketones. Our structural, spectroscopic and kinetic studies suggest that chemoselective organic transformations occur on site-isolated, electron-deficient and coordinatively unsaturated metal centres at the SBUs via σ-bond metathesis pathways and as a result of the steric environment around the catalytic site. MOFs thus provide a novel platform for the development of highly active and affordable base metal catalysts for the sustainable synthesis of fine chemicals.

  16. Identifying Influential Nodes in Large-Scale Directed Networks: The Role of Clustering

    Science.gov (United States)

    Chen, Duan-Bing; Gao, Hui; Lü, Linyuan; Zhou, Tao

    2013-01-01

    Identifying influential nodes in very large-scale directed networks is a big challenge relevant to disparate applications, such as accelerating information propagation, controlling rumors and diseases, designing search engines, and understanding hierarchical organization of social and biological networks. Known methods range from node centralities, such as degree, closeness and betweenness, to diffusion-based processes, like PageRank and LeaderRank. Some of these methods already take into account the influences of a node’s neighbors but do not directly make use of the interactions among it’s neighbors. Local clustering is known to have negative impacts on the information spreading. We further show empirically that it also plays a negative role in generating local connections. Inspired by these facts, we propose a local ranking algorithm named ClusterRank, which takes into account not only the number of neighbors and the neighbors’ influences, but also the clustering coefficient. Subject to the susceptible-infected-recovered (SIR) spreading model with constant infectivity, experimental results on two directed networks, a social network extracted from delicious.com and a large-scale short-message communication network, demonstrate that the ClusterRank outperforms some benchmark algorithms such as PageRank and LeaderRank. Furthermore, ClusterRank can also be applied to undirected networks where the superiority of ClusterRank is significant compared with degree centrality and k-core decomposition. In addition, ClusterRank, only making use of local information, is much more efficient than global methods: It takes only 191 seconds for a network with about nodes, more than 15 times faster than PageRank. PMID:24204833

  17. Dual-Stack Single-Radio Communication Architecture for UAV Acting As a Mobile Node to Collect Data in WSNs

    Directory of Open Access Journals (Sweden)

    Ali Sayyed

    2015-09-01

    Full Text Available The use of mobile nodes to collect data in a Wireless Sensor Network (WSN has gained special attention over the last years. Some researchers explore the use of Unmanned Aerial Vehicles (UAVs as mobile node for such data-collection purposes. Analyzing these works, it is apparent that mobile nodes used in such scenarios are typically equipped with at least two different radio interfaces. The present work presents a Dual-Stack Single-Radio Communication Architecture (DSSRCA, which allows a UAV to communicate in a bidirectional manner with a WSN and a Sink node. The proposed architecture was specifically designed to support different network QoS requirements, such as best-effort and more reliable communications, attending both UAV-to-WSN and UAV-to-Sink communications needs. DSSRCA was implemented and tested on a real UAV, as detailed in this paper. This paper also includes a simulation analysis that addresses bandwidth consumption in an environmental monitoring application scenario. It includes an analysis of the data gathering rate that can be achieved considering different UAV flight speeds. Obtained results show the viability of using a single radio transmitter for collecting data from the WSN and forwarding such data to the Sink node.

  18. Dual-Stack Single-Radio Communication Architecture for UAV Acting As a Mobile Node to Collect Data in WSNs.

    Science.gov (United States)

    Sayyed, Ali; de Araújo, Gustavo Medeiros; Bodanese, João Paulo; Becker, Leandro Buss

    2015-09-16

    The use of mobile nodes to collect data in a Wireless Sensor Network (WSN) has gained special attention over the last years. Some researchers explore the use of Unmanned Aerial Vehicles (UAVs) as mobile node for such data-collection purposes. Analyzing these works, it is apparent that mobile nodes used in such scenarios are typically equipped with at least two different radio interfaces. The present work presents a Dual-Stack Single-Radio Communication Architecture (DSSRCA), which allows a UAV to communicate in a bidirectional manner with a WSN and a Sink node. The proposed architecture was specifically designed to support different network QoS requirements, such as best-effort and more reliable communications, attending both UAV-to-WSN and UAV-to-Sink communications needs. DSSRCA was implemented and tested on a real UAV, as detailed in this paper. This paper also includes a simulation analysis that addresses bandwidth consumption in an environmental monitoring application scenario. It includes an analysis of the data gathering rate that can be achieved considering different UAV flight speeds. Obtained results show the viability of using a single radio transmitter for collecting data from the WSN and forwarding such data to the Sink node.

  19. Radiological-lymphographical and morphological early changes in canine lymph nodes after a single X-ray irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Ghobadi, M

    1973-07-06

    The opened lymph nodes of the popliteal fossa and of the supraclavicular fossa of 13 adult shepherd dogs were treated with a single dose of 1,000, 2,000, 3,000 R of a medium-hard radiation. The experiments have showed that a focal dose of 3,000 R and the time of one hour to four weeks after exposure to radiation is the optimum for the investigation of the radiological-lymphographical and morphological early changes. A total of 99 lymph nodes were examined morphologically. The morphological examinations showed changes marked by the occurrence of nuclear fragments, macrophages, oedemas, and haemorrhages. The planimetric measuring of the 42 lymph modes which had been iradiated and afterwards lymphographed did not show any significant differences when compared with the 49 lymph nodes which were only lymphographed. It is peculiar, however, that the arithmetical average of the measured surface of all 4 irradiated lymph-exudation areas is higher than the average of the ones which were only lymphographed. The examination results show that a single irradiation of the canine lymph nodes is marked by with a focal dose of 3,000 R within the first 4 weeks after the attack caused by radiation. The filtering function of the irradiated lymph nodes, which are measured by the lymphogram, do not show any changes when compared with the ones only lymphographed.

  20. Properties of a GaAs Single Electron Path Switching Node Device Using a Single Quantum Dot for Hexagonal BDD Quantum Circuits

    International Nuclear Information System (INIS)

    Nakamura, Tatsuya; Abe, Yuji; Kasai, Seiya; Hasegawa, Hideki; Hashizume, Tamotsu

    2006-01-01

    A new single electron (SE) binary-decision diagram (BDD) node device having a single quantum dot connected to three nanowire branches through tunnel barriers was fabricated using etched AlGaAs/GaAs nanowires and nanometer-sized Schottky wrap gates (WPGs), and their operation was characterized experimentally, for the hexagonal BDD quantum circuit. Fabricated devices showed clear and steep single electron pass switching by applying only an input voltage signal, which was completely different from switching properties in the previous SE BDD node devices composed of two single electron switches. As the possible switching mechanism, the correlation between the probabilities of tunnelling thorough a single quantum dot in exit branches was discussed

  1. Node-based finite element method for large-scale adaptive fluid analysis in parallel environments

    Energy Technology Data Exchange (ETDEWEB)

    Toshimitsu, Fujisawa [Tokyo Univ., Collaborative Research Center of Frontier Simulation Software for Industrial Science, Institute of Industrial Science (Japan); Genki, Yagawa [Tokyo Univ., Department of Quantum Engineering and Systems Science (Japan)

    2003-07-01

    In this paper, a FEM-based (finite element method) mesh free method with a probabilistic node generation technique is presented. In the proposed method, all computational procedures, from the mesh generation to the solution of a system of equations, can be performed fluently in parallel in terms of nodes. Local finite element mesh is generated robustly around each node, even for harsh boundary shapes such as cracks. The algorithm and the data structure of finite element calculation are based on nodes, and parallel computing is realized by dividing a system of equations by the row of the global coefficient matrix. In addition, the node-based finite element method is accompanied by a probabilistic node generation technique, which generates good-natured points for nodes of finite element mesh. Furthermore, the probabilistic node generation technique can be performed in parallel environments. As a numerical example of the proposed method, we perform a compressible flow simulation containing strong shocks. Numerical simulations with frequent mesh refinement, which are required for such kind of analysis, can effectively be performed on parallel processors by using the proposed method. (authors)

  2. Node-based finite element method for large-scale adaptive fluid analysis in parallel environments

    International Nuclear Information System (INIS)

    Toshimitsu, Fujisawa; Genki, Yagawa

    2003-01-01

    In this paper, a FEM-based (finite element method) mesh free method with a probabilistic node generation technique is presented. In the proposed method, all computational procedures, from the mesh generation to the solution of a system of equations, can be performed fluently in parallel in terms of nodes. Local finite element mesh is generated robustly around each node, even for harsh boundary shapes such as cracks. The algorithm and the data structure of finite element calculation are based on nodes, and parallel computing is realized by dividing a system of equations by the row of the global coefficient matrix. In addition, the node-based finite element method is accompanied by a probabilistic node generation technique, which generates good-natured points for nodes of finite element mesh. Furthermore, the probabilistic node generation technique can be performed in parallel environments. As a numerical example of the proposed method, we perform a compressible flow simulation containing strong shocks. Numerical simulations with frequent mesh refinement, which are required for such kind of analysis, can effectively be performed on parallel processors by using the proposed method. (authors)

  3. Investigation of Inter-Node B Macro Diversity for Single-Carrier Based Radio Access in Evolved UTRA Uplink

    Science.gov (United States)

    Kawai, Hiroyuki; Morimoto, Akihito; Higuchi, Kenichi; Sawahashi, Mamoru

    This paper investigates the gain of inter-Node B macro diversity for a scheduled-based shared channel using single-carrier FDMA radio access in the Evolved UTRA (UMTS Terrestrial Radio Access) uplink based on system-level simulations. More specifically, we clarify the gain of inter-Node B soft handover (SHO) with selection combining at the radio frame length level (=10msec) compared to that for hard handover (HHO) for a scheduled-based shared data channel, considering the gains of key packet-specific techniques including channel-dependent scheduling, adaptive modulation and coding (AMC), hybrid automatic repeat request (ARQ) with packet combining, and slow transmission power control (TPC). Simulation results show that the inter-Node B SHO increases the user throughput at the cell edge by approximately 10% for a short cell radius such as 100-300m due to the diversity gain from a sudden change in other-cell interference, which is a feature specific to full scheduled-based packet access. However, it is also shown that the gain of inter-Node B SHO compared to that for HHO is small in a macrocell environment when the cell radius is longer than approximately 500m due to the gains from hybrid ARQ with packet combining, slow TPC, and proportional fairness based channel-dependent scheduling.

  4. Ergodicity breakdown and scaling from single sequences

    Energy Technology Data Exchange (ETDEWEB)

    Kalashyan, Armen K. [Center for Nonlinear Science, University of North Texas, P.O. Box 311427, Denton, TX 76203-1427 (United States); Buiatti, Marco [Laboratoire de Neurophysique et Physiologie, CNRS UMR 8119 Universite Rene Descartes - Paris 5 45, rue des Saints Peres, 75270 Paris Cedex 06 (France); Cognitive Neuroimaging Unit - INSERM U562, Service Hospitalier Frederic Joliot, CEA/DRM/DSV, 4 Place du general Leclerc, 91401 Orsay Cedex (France); Grigolini, Paolo [Center for Nonlinear Science, University of North Texas, P.O. Box 311427, Denton, TX 76203-1427 (United States); Dipartimento di Fisica ' E.Fermi' - Universita di Pisa and INFM, Largo Pontecorvo 3, 56127 Pisa (Italy); Istituto dei Processi Chimico, Fisici del CNR Area della Ricerca di Pisa, Via G. Moruzzi 1, 56124 Pisa (Italy)], E-mail: grigo@df.unipi.it

    2009-01-30

    In the ergodic regime, several methods efficiently estimate the temporal scaling of time series characterized by long-range power-law correlations by converting them into diffusion processes. However, in the condition of ergodicity breakdown, the same methods give ambiguous results. We show that in such regime, two different scaling behaviors emerge depending on the age of the windows used for the estimation. We explain the ambiguity of the estimation methods by the different influence of the two scaling behaviors on each method. Our results suggest that aging drastically alters the scaling properties of non-ergodic processes.

  5. Ergodicity breakdown and scaling from single sequences

    International Nuclear Information System (INIS)

    Kalashyan, Armen K.; Buiatti, Marco; Grigolini, Paolo

    2009-01-01

    In the ergodic regime, several methods efficiently estimate the temporal scaling of time series characterized by long-range power-law correlations by converting them into diffusion processes. However, in the condition of ergodicity breakdown, the same methods give ambiguous results. We show that in such regime, two different scaling behaviors emerge depending on the age of the windows used for the estimation. We explain the ambiguity of the estimation methods by the different influence of the two scaling behaviors on each method. Our results suggest that aging drastically alters the scaling properties of non-ergodic processes.

  6. Salvage Stereotactic Body Radiotherapy for Isolated Lymph Node Recurrent Prostate Cancer: Single Institution Series of 94 Consecutive Patients and 124 Lymph Nodes.

    Science.gov (United States)

    Jereczek-Fossa, Barbara Alicja; Fanetti, Giuseppe; Fodor, Cristiana; Ciardo, Delia; Santoro, Luigi; Francia, Claudia Maria; Muto, Matteo; Surgo, Alessia; Zerini, Dario; Marvaso, Giulia; Timon, Giorgia; Romanelli, Paola; Rondi, Elena; Comi, Stefania; Cattani, Federica; Golino, Federica; Mazza, Stefano; Matei, Deliu Victor; Ferro, Matteo; Musi, Gennaro; Nolè, Franco; de Cobelli, Ottavio; Ost, Piet; Orecchia, Roberto

    2017-08-01

    The purpose of the study was to evaluate the prostate serum antigen (PSA) response, local control, progression-free survival (PFS), and toxicity of stereotactic body radiotherapy (SBRT) for lymph node (LN) oligorecurrent prostate cancer. Between May 2012 and October 2015, 124 lesions were treated in 94 patients with a median dose of 24 Gy in 3 fractions. Seventy patients were treated for a single lesion and 25 for > 1 lesion. In 34 patients androgen deprivation (AD) was combined with SBRT. We evaluated biochemical response according to PSA level every 3 months after SBRT: a 3-month PSA decrease from pre-SBRT PSA of more than 10% identified responder patients. In case of PSA level increase, imaging was performed to evaluate clinical progression. Toxicity was assessed every 6 to 9 months after SBRT. Median follow-up was 18.5 months. In 13 patients (14%) Grade 1 to 2 toxicity was reported without any Grade 3 to 4 toxicity. Biochemical response, stabilization, and progression were observed in 64 (68%), 10 (11%), and 20 (21%) of 94 evaluable patients. Clinical progression was observed in 31 patients (33%) after a median time of 8.1 months. In-field progression occurred in 12 lesions (9.7%). Two-year local control and PFS rates were 84% and 30%, respectively. Age older than 75 years correlated with better biochemical response rate. Age older than 75 years, concomitant AD administered up to 12 months, and pelvic LN involvement correlated with longer PFS. SBRT is safe and offers good in-field control. At 2 years after SBRT, 1 of 3 patients is progression-free. Further investigation is warranted to identify patients who benefit most from SBRT and to define the optimal combination with AD. Copyright © 2017 Elsevier Inc. All rights reserved.

  7. Robust node estimation and topology discovery for large-scale networks

    KAUST Repository

    Alouini, Mohamed-Slim

    2017-02-23

    Various examples are provided for node estimation and topology discovery for networks. In one example, a method includes receiving a packet having an identifier from a first node; adding the identifier to another transmission packet based on a comparison between the first identifier and existing identifiers associated with the other packet; adjusting a transmit probability based on the comparison; and transmitting the other packet based on a comparison between the transmit probability and a probability distribution. In another example, a system includes a network device that can adds an identifier received in a packet to a list including existing identifiers and adjust a transmit probability based on a comparison between the identifiers; and transmit another packet based on a comparison between the transmit probability and a probability distribution. In another example, a method includes determining a quantity of sensor devices based on a plurality of identifiers received in a packet.

  8. Robust node estimation and topology discovery for large-scale networks

    KAUST Repository

    Alouini, Mohamed-Slim; Douik, Ahmed S.; Aly, Salah A.; Al-Naffouri, Tareq Y.

    2017-01-01

    Various examples are provided for node estimation and topology discovery for networks. In one example, a method includes receiving a packet having an identifier from a first node; adding the identifier to another transmission packet based on a comparison between the first identifier and existing identifiers associated with the other packet; adjusting a transmit probability based on the comparison; and transmitting the other packet based on a comparison between the transmit probability and a probability distribution. In another example, a system includes a network device that can adds an identifier received in a packet to a list including existing identifiers and adjust a transmit probability based on a comparison between the identifiers; and transmit another packet based on a comparison between the transmit probability and a probability distribution. In another example, a method includes determining a quantity of sensor devices based on a plurality of identifiers received in a packet.

  9. Sentinel lymph node biopsy in thick malignant melanoma: A 16-year single unit experience.

    Science.gov (United States)

    Hunger, Robert E; Michel, Aude; Seyed Jafari, S Morteza; Shafighi, Maziar

    2015-01-01

    The role of sentinel lymph node biopsy (SLNB) and its benefits in patients with thick melanoma is still controversial. We evaluated the clinical effect of SLNB in patients with thick melanoma. We performed a retrospective cohort review (1996-2012) of thick melanomas. Collected data included the patient and tumour characteristics. Locoregional recurrence, distant metastases, disease free and overall survival were compared between the patients with positive and negative SLNB. 126 thick melanomas with a mean age of 64.09 years were included in the study. Positive SLNB were found in 47 (37.3%) patients. Significantly more locoregional recurrence (P = 0.002) and distant metastases (P = 0.030) were detected in the patients with positive SLNB. Furthermore, the patients with negative SLNB showed significantly better disease free survival (P = 0.021). Positive SLNB might be prognostic factor in thick melanoma and aggravates the outcome of thick melanomas.

  10. Asynchronous Task-Based Polar Decomposition on Single Node Manycore Architectures

    KAUST Repository

    Sukkari, Dalal E.; Ltaief, Hatem; Faverge, Mathieu; Keyes, David E.

    2017-01-01

    This paper introduces the first asynchronous, task-based formulation of the polar decomposition and its corresponding implementation on manycore architectures. Based on a formulation of the iterative QR dynamically-weighted Halley algorithm (QDWH) for the calculation of the polar decomposition, the proposed implementation replaces the original LU factorization for the condition number estimator by the more adequate QR factorization to enable software portability across various architectures. Relying on fine-grained computations, the novel task-based implementation is capable of taking advantage of the identity structure of the matrix involved during the QDWH iterations, which decreases the overall algorithmic complexity. Furthermore, the artifactual synchronization points have been weakened compared to previous implementations, unveiling look-ahead opportunities for better hardware occupancy. The overall QDWH-based polar decomposition can then be represented as a directed acyclic graph (DAG), where nodes represent computational tasks and edges define the inter-task data dependencies. The StarPU dynamic runtime system is employed to traverse the DAG, to track the various data dependencies and to asynchronously schedule the computational tasks on the underlying hardware resources, resulting in an out-of-order task scheduling. Benchmarking experiments show significant improvements against existing state-of-the-art high performance implementations for the polar decomposition on latest shared-memory vendors' systems, while maintaining numerical accuracy.

  11. Asynchronous Task-Based Polar Decomposition on Single Node Manycore Architectures

    KAUST Repository

    Sukkari, Dalal E.

    2017-09-29

    This paper introduces the first asynchronous, task-based formulation of the polar decomposition and its corresponding implementation on manycore architectures. Based on a formulation of the iterative QR dynamically-weighted Halley algorithm (QDWH) for the calculation of the polar decomposition, the proposed implementation replaces the original LU factorization for the condition number estimator by the more adequate QR factorization to enable software portability across various architectures. Relying on fine-grained computations, the novel task-based implementation is capable of taking advantage of the identity structure of the matrix involved during the QDWH iterations, which decreases the overall algorithmic complexity. Furthermore, the artifactual synchronization points have been weakened compared to previous implementations, unveiling look-ahead opportunities for better hardware occupancy. The overall QDWH-based polar decomposition can then be represented as a directed acyclic graph (DAG), where nodes represent computational tasks and edges define the inter-task data dependencies. The StarPU dynamic runtime system is employed to traverse the DAG, to track the various data dependencies and to asynchronously schedule the computational tasks on the underlying hardware resources, resulting in an out-of-order task scheduling. Benchmarking experiments show significant improvements against existing state-of-the-art high performance implementations for the polar decomposition on latest shared-memory vendors\\' systems, while maintaining numerical accuracy.

  12. Optimal power and performance trade-offs for dynamic voltage scaling in power management based wireless sensor node

    Directory of Open Access Journals (Sweden)

    Anuradha Pughat

    2016-09-01

    Full Text Available Dynamic voltage scaling contributes to a significant amount of power saving, especially in the energy constrained wireless sensor networks (WSNs. Existing dynamic voltage scaling techniques make the system slower and ignore the event miss rate. This results in degradation of the system performance when there is non-stationary workload at input. The overhead due to transition between voltage level and discrete voltage levels are also the limitations of available dynamic voltage scaling (DVS techniques at sensor node (SN. This paper proposes a workload dependent DVS based MSP430 controller model used for SN. An online gradient estimation technique has been used to optimize power and performance trade-offs. The analytical results are validated with the simulation results obtained using simulation tool “SimEvents” and compared with the available AT9OS8535 controller. Based on the stochastic workload, the controller's input voltage, operational frequency, utilization, and average wait time of events are obtained.

  13. Testing on a Large Scale Running the ATLAS Data Acquisition and High Level Trigger Software on 700 PC Nodes

    CERN Document Server

    Burckhart-Chromek, Doris; Adragna, P; Alexandrov, L; Amorim, A; Armstrong, S; Badescu, E; Baines, J T M; Barros, N; Beck, H P; Bee, C; Blair, R; Bogaerts, J A C; Bold, T; Bosman, M; Caprini, M; Caramarcu, C; Ciobotaru, M; Comune, G; Corso-Radu, A; Cranfield, R; Crone, G; Dawson, J; Della Pietra, M; Di Mattia, A; Dobinson, Robert W; Dobson, M; Dos Anjos, A; Dotti, A; Drake, G; Ellis, Nick; Ermoline, Y; Ertorer, E; Falciano, S; Ferrari, R; Ferrer, M L; Francis, D; Gadomski, S; Gameiro, S; Garitaonandia, H; Gaudio, G; George, S; Gesualdi-Mello, A; Gorini, B; Green, B; Haas, S; Haberichter, W N; Hadavand, H; Haeberli, C; Haller, J; Hansen, J; Hauser, R; Hillier, S J; Höcker, A; Hughes-Jones, R E; Joos, M; Kazarov, A; Kieft, G; Klous, S; Kohno, T; Kolos, S; Korcyl, K; Kordas, K; Kotov, V; Kugel, A; Landon, M; Lankford, A; Leahu, L; Leahu, M; Lehmann-Miotto, G; Le Vine, M J; Liu, W; Maeno, T; Männer, R; Mapelli, L; Martin, B; Masik, J; McLaren, R; Meessen, C; Meirosu, C; Mineev, M; Misiejuk, A; Morettini, P; Mornacchi, G; Müller, M; Garcia-Murillo, R; Nagasaka, Y; Negri, A; Padilla, C; Pasqualucci, E; Pauly, T; Perera, V; Petersen, J; Pope, B; Albuquerque-Portes, M; Pretzl, K; Prigent, D; Roda, C; Ryabov, Yu; Salvatore, D; Schiavi, C; Schlereth, J L; Scholtes, I; Sole-Segura, E; Seixas, M; Sloper, J; Soloviev, I; Spiwoks, R; Stamen, R; Stancu, S; Strong, S; Sushkov, S; Szymocha, T; Tapprogge, S; Teixeira-Dias, P; Torres, R; Touchard, F; Tremblet, L; Ünel, G; Van Wasen, J; Vandelli, W; Vaz-Gil-Lopes, L; Vermeulen, J C; von der Schmitt, H; Wengler, T; Werner, P; Wheeler, S; Wickens, F; Wiedenmann, W; Wiesmann, M; Wu, X; Yasu, Y; Yu, M; Zema, F; Zobernig, H; Computing In High Energy and Nuclear Physics

    2006-01-01

    The ATLAS Data Acquisition (DAQ) and High Level Trigger (HLT) software system will be comprised initially of 2000 PC nodes which take part in the control, event readout, second level trigger and event filter operations. This high number of PCs will only be purchased before data taking in 2007. The large CERN IT LXBATCH facility provided the opportunity to run in July 2005 online functionality tests over a period of 5 weeks on a stepwise increasing farm size from 100 up to 700 PC dual nodes. The interplay between the control and monitoring software with the event readout, event building and the trigger software has been exercised the first time as an integrated system on this large scale. New was also to run algorithms in the online environment for the trigger selection and in the event filter processing tasks on a larger scale. A mechanism has been developed to package the offline software together with the DAQ/HLT software and to distribute it via peer-to-peer software efficiently to this large pc cluster. T...

  14. Testing on a Large Scale running the ATLAS Data Acquisition and High Level Trigger Software on 700 PC Nodes

    CERN Document Server

    Burckhart-Chromek, Doris; Adragna, P; Albuquerque-Portes, M; Alexandrov, L; Amorim, A; Armstrong, S; Badescu, E; Baines, J T M; Barros, N; Beck, H P; Bee, C; Blair, R; Bogaerts, J A C; Bold, T; Bosman, M; Caprini, M; Caramarcu, C; Ciobotaru, M; Comune, G; Corso-Radu, A; Cranfield, R; Crone, G; Dawson, J; Della Pietra, M; Di Mattia, A; Dobinson, Robert W; Dobson, M; Dos Anjos, A; Dotti, A; Drake, G; Ellis, Nick; Ermoline, Y; Ertorer, E; Falciano, S; Ferrari, R; Ferrer, M L; Francis, D; Gadomski, S; Gameiro, S; Garcia-Murillo, R; Garitaonandia, H; Gaudio, G; George, S; Gesualdi-Mello, A; Gorini, B; Green, B; Haas, S; Haberichter, W N; Hadavand, H; Haeberli, C; Haller, J; Hansen, J; Hauser, R; Hillier, S J; Hughes-Jones, R E; Höcker, A; Joos, M; Kazarov, A; Kieft, G; Klous, S; Kohno, T; Kolos, S; Korcyl, K; Kordas, K; Kotov, V; Kugel, A; Landon, M; Lankford, A; Le Vine, M J; Leahu, L; Leahu, M; Lehmann-Miotto, G; Liu, W; Maeno, T; Mapelli, L; Martin, B; Masik, J; McLaren, R; Meessen, C; Meirosu, C; Mineev, M; Misiejuk, A; Morettini, P; Mornacchi, G; Männer, R; Müller, M; Nagasaka, Y; Negri, A; Padilla, C; Pasqualucci, E; Pauly, T; Perera, V; Petersen, J; Pope, B; Pretzl, K; Prigent, D; Roda, C; Ryabov, Yu; Salvatore, D; Schiavi, C; Schlereth, J L; Scholtes, I; Seixas, M; Sloper, J; Sole-Segura, E; Soloviev, I; Spiwoks, R; Stamen, R; Stancu, S; Strong, S; Sushkov, S; Szymocha, T; Tapprogge, S; Teixeira-Dias, P; Torres, R; Touchard, F; Tremblet, L; Van Wasen, J; Vandelli, W; Vaz-Gil-Lopes, L; Vermeulen, J C; Wengler, T; Werner, P; Wheeler, S; Wickens, F; Wiedenmann, W; Wiesmann, M; Wu, X; Yasu, Y; Yu, M; Zema, F; Zobernig, H; von der Schmitt, H; Ünel, G; Computing In High Energy and Nuclear Physics

    2006-01-01

    The ATLAS Data Acquisition (DAQ) and High Level Trigger (HLT) software system will be comprised initially of 2000 PC nodes which take part in the control, event readout, second level trigger and event filter operations. This high number of PCs will only be purchased before data taking in 2007. The large CERN IT LXBATCH facility provided the opportunity to run in July 2005 online functionality tests over a period of 5 weeks on a stepwise increasing farm size from 100 up to 700 PC dual nodes. The interplay between the control and monitoring software with the event readout, event building and the trigger software has been exercised the first time as an integrated system on this large scale. New was also to run algorithms in the online environment for the trigger selection and in the event filter processing tasks on a larger scale. A mechanism has been developed to package the offline software together with the DAQ/HLT software and to distribute it via peer-to-peer software efficiently to this large pc cluster. T...

  15. The predictive value of single-photon emission computed tomography/computed tomography for sentinel lymph node localization in head and neck cutaneous malignancy.

    Science.gov (United States)

    Remenschneider, Aaron K; Dilger, Amanda E; Wang, Yingbing; Palmer, Edwin L; Scott, James A; Emerick, Kevin S

    2015-04-01

    Preoperative localization of sentinel lymph nodes in head and neck cutaneous malignancies can be aided by single-photon emission computed tomography/computed tomography (SPECT/CT); however, its true predictive value for identifying lymph nodes intraoperatively remains unquantified. This study aims to understand the sensitivity, specificity, and positive and negative predictive values of SPECT/CT in sentinel lymph node biopsy for cutaneous malignancies of the head and neck. Blinded retrospective imaging review with comparison to intraoperative gamma probe confirmed sentinel lymph nodes. A consecutive series of patients with a head and neck cutaneous malignancy underwent preoperative SPECT/CT followed by sentinel lymph node biopsy with a gamma probe. Two nuclear medicine physicians, blinded to clinical data, independently reviewed each SPECT/CT. Activity within radiographically defined nodal basins was recorded and compared to intraoperative gamma probe findings. Sensitivity, specificity, and negative and positive predictive values were calculated with subgroup stratification by primary tumor site. Ninety-two imaging reads were performed on 47 patients with cutaneous malignancy who underwent SPECT/CT followed by sentinel lymph node biopsy. Overall sensitivity was 73%, specificity 92%, positive predictive value 54%, and negative predictive value 96%. The predictive ability of SPECT/CT to identify the basin or an adjacent basin containing the single hottest node was 92%. SPECT/CT overestimated uptake by an average of one nodal basin. In the head and neck, SPECT/CT has higher reliability for primary lesions of the eyelid, scalp, and cheek. SPECT/CT has high sensitivity, specificity, and negative predictive value, but may overestimate relevant nodal basins in sentinel lymph node biopsy. © 2014 The American Laryngological, Rhinological and Otological Society, Inc.

  16. Optimal dynamic voltage scaling for wireless sensor nodes with real-time constraints

    Science.gov (United States)

    Cassandras, Christos G.; Zhuang, Shixin

    2005-11-01

    Sensors are increasingly embedded in manufacturing systems and wirelessly networked to monitor and manage operations ranging from process and inventory control to tracking equipment and even post-manufacturing product monitoring. In building such sensor networks, a critical issue is the limited and hard to replenish energy in the devices involved. Dynamic voltage scaling is a technique that controls the operating voltage of a processor to provide desired performance while conserving energy and prolonging the overall network's lifetime. We consider such power-limited devices processing time-critical tasks which are non-preemptive, aperiodic and have uncertain arrival times. We treat voltage scaling as a dynamic optimization problem whose objective is to minimize energy consumption subject to hard or soft real-time execution constraints. In the case of hard constraints, we build on prior work (which engages a voltage scaling controller at task completion times) by developing an intra-task controller that acts at all arrival times of incoming tasks. We show that this optimization problem can be decomposed into two simpler ones whose solution leads to an algorithm that does not actually require solving any nonlinear programming problems. In the case of soft constraints, this decomposition must be partly relaxed, but it still leads to a scalable (linear in the number of tasks) algorithm. Simulation results are provided to illustrate performance improvements in systems with intra-task controllers compared to uncontrolled systems or those using inter-task control.

  17. Pathological mechanisms underlying single large‐scale mitochondrial DNA deletions

    Science.gov (United States)

    Rocha, Mariana C.; Rosa, Hannah S.; Grady, John P.; Blakely, Emma L.; He, Langping; Romain, Nadine; Haller, Ronald G.; Newman, Jane; McFarland, Robert; Ng, Yi Shiau; Gorman, Grainne S.; Schaefer, Andrew M.; Tuppen, Helen A.; Taylor, Robert W.

    2018-01-01

    Objective Single, large‐scale deletions in mitochondrial DNA (mtDNA) are a common cause of mitochondrial disease. This study aimed to investigate the relationship between the genetic defect and molecular phenotype to improve understanding of pathogenic mechanisms associated with single, large‐scale mtDNA deletions in skeletal muscle. Methods We investigated 23 muscle biopsies taken from adult patients (6 males/17 females with a mean age of 43 years) with characterized single, large‐scale mtDNA deletions. Mitochondrial respiratory chain deficiency in skeletal muscle biopsies was quantified by immunoreactivity levels for complex I and complex IV proteins. Single muscle fibers with varying degrees of deficiency were selected from 6 patient biopsies for determination of mtDNA deletion level and copy number by quantitative polymerase chain reaction. Results We have defined 3 “classes” of single, large‐scale deletion with distinct patterns of mitochondrial deficiency, determined by the size and location of the deletion. Single fiber analyses showed that fibers with greater respiratory chain deficiency harbored higher levels of mtDNA deletion with an increase in total mtDNA copy number. For the first time, we have demonstrated that threshold levels for complex I and complex IV deficiency differ based on deletion class. Interpretation Combining genetic and immunofluorescent assays, we conclude that thresholds for complex I and complex IV deficiency are modulated by the deletion of complex‐specific protein‐encoding genes. Furthermore, removal of mt‐tRNA genes impacts specific complexes only at high deletion levels, when complex‐specific protein‐encoding genes remain. These novel findings provide valuable insight into the pathogenic mechanisms associated with these mutations. Ann Neurol 2018;83:115–130 PMID:29283441

  18. Scaling of ion implanted Si:P single electron devices

    International Nuclear Information System (INIS)

    Escott, C C; Hudson, F E; Chan, V C; Petersson, K D; Clark, R G; Dzurak, A S

    2007-01-01

    We present a modelling study on the scaling prospects for phosphorus in silicon (Si:P) single electron devices using readily available commercial and free-to-use software. The devices comprise phosphorus ion implanted, metallically doped (n + ) dots (size range 50-500 nm) with source and drain reservoirs. Modelling results are compared to measurements on fabricated devices and discussed in the context of scaling down to few-electron structures. Given current fabrication constraints, we find that devices with 70-75 donors per dot should be realizable. We comment on methods for further reducing this number

  19. Scaling of ion implanted Si:P single electron devices

    Energy Technology Data Exchange (ETDEWEB)

    Escott, C C [Centre for Quantum Computer Technology, School of Electrical Engineering and Telecommunications, UNSW, Sydney, NSW 2052 (Australia); Hudson, F E [Centre for Quantum Computer Technology, School of Electrical Engineering and Telecommunications, UNSW, Sydney, NSW 2052 (Australia); Chan, V C [Centre for Quantum Computer Technology, School of Electrical Engineering and Telecommunications, UNSW, Sydney, NSW 2052 (Australia); Petersson, K D [Centre for Quantum Computer Technology, School of Electrical Engineering and Telecommunications, UNSW, Sydney, NSW 2052 (Australia); Clark, R G [Centre for Quantum Computer Technology, School of Physics, UNSW, Sydney, 2052 (Australia); Dzurak, A S [Centre for Quantum Computer Technology, School of Electrical Engineering and Telecommunications, UNSW, Sydney, NSW 2052 (Australia)

    2007-06-13

    We present a modelling study on the scaling prospects for phosphorus in silicon (Si:P) single electron devices using readily available commercial and free-to-use software. The devices comprise phosphorus ion implanted, metallically doped (n{sup +}) dots (size range 50-500 nm) with source and drain reservoirs. Modelling results are compared to measurements on fabricated devices and discussed in the context of scaling down to few-electron structures. Given current fabrication constraints, we find that devices with 70-75 donors per dot should be realizable. We comment on methods for further reducing this number.

  20. Influence of Guest Exchange on the Magnetization Dynamics of Dilanthanide Single-Molecule-Magnet Nodes within a Metal-Organic Framework.

    Science.gov (United States)

    Zhang, Xuejing; Vieru, Veacheslav; Feng, Xiaowen; Liu, Jun-Liang; Zhang, Zhenjie; Na, Bo; Shi, Wei; Wang, Bing-Wu; Powell, Annie K; Chibotaru, Liviu F; Gao, Song; Cheng, Peng; Long, Jeffrey R

    2015-08-17

    Multitopic organic linkers can provide a means to organize metal cluster nodes in a regular three-dimensional array. Herein, we show that isonicotinic acid N-oxide (HINO) serves as the linker in the formation of a metal-organic framework featuring Dy2 single-molecule magnets as nodes. Importantly, guest solvent exchange induces a reversible single-crystal to single-crystal transformation between the phases Dy2(INO)4(NO3)2⋅2 solvent (solvent=DMF (Dy2-DMF), CH3CN (Dy2-CH3CN)), thereby switching the effective magnetic relaxation barrier (determined by ac magnetic susceptibility measurements) between a negligible value for Dy2-DMF and 76 cm(-1) for Dy2-CH3CN. Ab initio calculations indicate that this difference arises not from a significant change in the intrinsic relaxation barrier of the Dy2 nodes, but rather from a slowing of the relaxation rate of incoherent quantum tunneling of the magnetization by two orders of magnitude. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. MORBIDITY OF SENTINEL LYMPH NODE BIOPSY (SLNB ALONE VERSUS SLNB AND COMPLETION AXILLARY LYMPH NODE DISSECTION AFTER BREAST CANCER SURGERY- A PROSPECTIVE SINGLE CENTRE STUDY

    Directory of Open Access Journals (Sweden)

    Mythilidevi Sappa

    2017-11-01

    Full Text Available BACKGROUND ALND after breast cancer surgery is associated with considerable morbidity. We hypothesised- 1 The morbidity in patients undergoing SLN biopsy only is significantly lower compared with those after SLN and completion ALND level I and II; and 2 The intermediate survival rates, local and axillary recurrence rates were significantly equivalent in both the groups. MATERIALS AND METHODS Patients with early stage breast cancer (pT1 and pT2 ≤3 cm, cN0 were included between April 2010 and April 2016 in this prospective single centre study. All patients underwent SLN biopsy. In all patients with SLN macrometastases and most patients with SLN micrometastases (43 of 68 or isolated tumour cells (11 of 19, a completion ALND was performed. Postoperative morbidity was assessed based on a standardised protocol. RESULTS SLN biopsy alone was performed in 449 patients, whereas 210 patients underwent SLN and completion ALND. The median follow-ups were 31.0 and 29.5 months for the SLN and SLN and completion ALND groups, respectively. Intermediate-term follow-up information was available from 635 of 659 patients (96.4% of enrolled patients. The following results were found in the SLN versus SLN and completion ALND group- Presence of lymphoedema (3.5% vs. 19.1%, P <0.0001, impaired shoulder range of motion (3.5% vs. 11.3%, P <0.0001, shoulder/arm pain (8.1% vs. 21.1%, P <0.0001 and numbness (10.9% vs. 37.7%, P <0.0001. CONCLUSION The morbidity after SLN biopsy alone is not negligible, but significantly lower compared with ALND. The intermediate survival rates, local and axillary recurrence rates were equivalent in SLNB only and SLNB plus completion ALND groups.

  2. Node cookbook

    CERN Document Server

    Clements, David Mark

    2014-01-01

    In Node Cookbook Second Edition, each chapter focuses on a different aspect of working with Node. Following a Cookbook structure, the recipes are written in an easy-to-understand language. Readers will find it easier to grasp even the complex recipes which are backed by lots of illustrations, tips, and hints.If you have some knowledge of JavaScript and want to build fast, efficient, scalable client-server solutions, then Node Cookbook Second Edition is for you. Knowledge of Node will be an advantage but is not required. Experienced users of Node will be able to improve their skills.

  3. The Added Value of a Single-photon Emission Computed Tomography-Computed Tomography in Sentinel Lymph Node Mapping in Patients with Breast Cancer and Malignant Melanoma.

    Science.gov (United States)

    Bennie, George; Vorster, Mariza; Buscombe, John; Sathekge, Mike

    2015-01-01

    Single-photon emission computed tomography-computed tomography (SPECT-CT) allows for physiological and anatomical co-registration in sentinel lymph node (SLN) mapping and offers additional benefits over conventional planar imaging. However, the clinical relevance when considering added costs and radiation burden of these reported benefits remains somewhat uncertain. This study aimed to evaluate the possible added value of SPECT-CT and intra-operative gamma-probe use over planar imaging alone in the South African setting. 80 patients with breast cancer or malignant melanoma underwent both planar and SPECT-CT imaging for SLN mapping. We assessed and compared the number of nodes detected on each study, false positive and negative findings, changes in surgical approach and or patient management. In all cases where a sentinel node was identified, SPECT-CT was more accurate anatomically. There was a significant change in surgical approach in 30 cases - breast cancer (n = 13; P 0.001) and malignant melanoma (n = 17; P 0.0002). In 4 cases a node not identified on planar imaging was seen on SPECT-CT. In 16 cases additional echelon nodes were identified. False positives were excluded by SPECT-CT in 12 cases. The addition of SPECT-CT and use of intra-operative gamma-probe to planar imaging offers important benefits in patients who present with breast cancer and melanoma. These benefits include increased nodal detection, elimination of false positives and negatives and improved anatomical localization that ultimately aids and expedites surgical management. This has been demonstrated in the context of industrialized country previously and has now also been confirmed in the setting of a emerging-market nation.

  4. The Added Value of a Single-photon Emission Computed Tomography-Computed Tomography in Sentinel Lymph Node Mapping in Patients with Breast Cancer and Malignant Melanoma

    International Nuclear Information System (INIS)

    Bennie, George; Vorster, Mariza; Buscombe, John; Sathekge, Mike

    2015-01-01

    Single-photon emission computed tomography-computed tomography (SPECT-CT) allows for physiological and anatomical co-registration in sentinel lymph node (SLN) mapping and offers additional benefits over conventional planar imaging. However, the clinical relevance when considering added costs and radiation burden of these reported benefits remains somewhat uncertain. This study aimed to evaluate the possible added value of SPECT-CT and intra-operative gamma-probe use over planar imaging alone in the South African setting. 80 patients with breast cancer or malignant melanoma underwent both planar and SPECT-CT imaging for SLN mapping. We assessed and compared the number of nodes detected on each study, false positive and negative findings, changes in surgical approach and or patient management. In all cases where a sentinel node was identified, SPECT-CT was more accurate anatomically. There was a significant change in surgical approach in 30 cases - breast cancer (n = 13; P 0.001) and malignant melanoma (n = 17; P 0.0002). In 4 cases a node not identified on planar imaging was seen on SPECT-CT. In 16 cases additional echelon nodes were identified. False positives were excluded by SPECT-CT in 12 cases. The addition of SPECT-CT and use of intra-operative gamma-probe to planar imaging offers important benefits in patients who present with breast cancer and melanoma. These benefits include increased nodal detection, elimination of false positives and negatives and improved anatomical localization that ultimately aids and expedites surgical management. This has been demonstrated in the context of industrialized country previously and has now also been confirmed in the setting of a emerging-market nation

  5. Development and validation of the Single Item Narcissism Scale (SINS).

    Science.gov (United States)

    Konrath, Sara; Meier, Brian P; Bushman, Brad J

    2014-01-01

    The narcissistic personality is characterized by grandiosity, entitlement, and low empathy. This paper describes the development and validation of the Single Item Narcissism Scale (SINS). Although the use of longer instruments is superior in most circumstances, we recommend the SINS in some circumstances (e.g. under serious time constraints, online studies). In 11 independent studies (total N = 2,250), we demonstrate the SINS' psychometric properties. The SINS is significantly correlated with longer narcissism scales, but uncorrelated with self-esteem. It also has high test-retest reliability. We validate the SINS in a variety of samples (e.g., undergraduates, nationally representative adults), intrapersonal correlates (e.g., positive affect, depression), and interpersonal correlates (e.g., aggression, relationship quality, prosocial behavior). The SINS taps into the more fragile and less desirable components of narcissism. The SINS can be a useful tool for researchers, especially when it is important to measure narcissism with constraints preventing the use of longer measures.

  6. Sentinel node mapping in endometrial cancer following Hysteroscopic injection of tracers: A single center evaluation over 200 cases.

    Science.gov (United States)

    Martinelli, Fabio; Ditto, Antonino; Signorelli, Mauro; Bogani, Giorgio; Chiappa, Valentina; Lorusso, Domenica; Scaffa, Cono; Recalcati, Dario; Perotto, Stefania; Haeusler, Edward; Raspagliesi, Francesco

    2017-09-01

    To analyze detection-rate(DR) and diagnostic-accuracy (A) of sentinel-nodes(SLNs) mapping following hysteroscopic-injection of tracer. To compare DR and A between tracers: ICG and Tc99m. Evaluation of endometrial-cancer patients who underwent SLNs mapping after hysteroscopic-peritumoral-injection of tracer±lymphadenectomy. Analysis of DR (overall-bilateral-aortic) and A in the entire cohort and comparison between tracers. 202 procedures were performed from January/2005 to February/2017. Mean age:60years (28-82); mean BMI: 26.8 kg/m 2 (15-47). In 133 cases (65.8%) hysterectomy and mapping procedure were performed laparoscopically. The overall-DR of the technique was 93.2% (179/192) (10 cases were excluded: 9 for technical-equipment failure; 1 for vagal reaction). Bilateral pelvic mapping was found in 59.7% of cases (107/179) and was more frequent in the ICG group (72.8% vs 53.3%; p: 0.012). In 50.8% of cases (91/179) SLNs were mapped both in pelvic and aortic nodes, and in 5 cases (2.8%) only in the aortic area. The mean number of detected SLNs was 3.7 (1-8). 22 patients (12.3%) had nodal involvement: 10-(45.5%)-macrometastases; 5-(22.7%)-micrometastases; 7-(31.8%)-ITCs. In 6 cases (27.3%) only aortic nodes were positive; in 5 cases (22.7%) both pelvic and aortic nodes and in 11 cases (50%) only pelvic nodes were involved. Three false-negative results were found, all in the Tc99m group. All had isolated aortic metastases with negative pelvic nodes. Overall-sensitivity was 86.4% (95%CI: 68.4-100) and overall-negative-predictive-value (NPV) was 96.4% (95%CI 86.7-100). No differences in terms of overall-DR, overall-sensitivity and overall-NPV were found between the two tracers. Hysteroscopic-injection of tracer for SLNs mapping in endometrial cancer is as accurate as cervical injection with a higher DR in the aortic area. ICG improves bilateral-DR. Further investigation is warranted on this topic. Copyright © 2017 Elsevier Inc. All rights reserved.

  7. CFD simulation of flow through single and multi vane spiral pump for low pressure application using moving node unsteady computation

    International Nuclear Information System (INIS)

    Banerjee, I.; Mahendra, A.K.; Chandresh, B.G.; Srikanthan, M.R.; Bera, T.K.

    2010-01-01

    A spiral pump uses two interleaved spirals (it can be involutes of a circle, involutes of a square, hybrid wraps, Archimedean spiral, logarithmic spirals and so on). Interleaved spiral orbits eccentrically without rotation around a fixed scroll, thereby trapping and compressing pockets of fluids between the spirals. Another method of providing the compression motion is by virtue of co-rotating the spirals synchronously with an offset in centers of rotation thereby providing relative motion similar to orbiting. Recently spiral pumps for low-pressure application have become popular. Since spiral pumps contain gas volumes, whose shapes and size change continuously, the flow fields inside the pumps is time dependent. The unsteadiness controls the mechanisms responsible for the behavior of the spiral pump components. To improve the spiral pump design for better performance as per our process requirement and reliability, information is required to understand the detailed physics of the unsteady flows inside the spiral pumps. The unsteady flows in a pump are studied numerically. The system simulated includes one side gap between fixed and moving spirals as the other side lies just in the reverse symmetry of the one side. Heavy molecular weight, condensable gas is used as the moving fluid. The mesh free Least Square Kinetic Upwind Method (LSKUM) for moving node is applied for numerical analysis of wobbling spiral. Nodes and boundaries change their positions, for every real time step hence at every iteration nodes take new coordinates. Our work consists of identifying various spiral dimensions and geometry, geometric modeling of suction process, identifying the eccentric orbiting motion of the moving spiral, formation of variable velocity moving nodes. Flow analysis of the spiral pump is done with a view to design and develop new pump as per our requirement. Experimental data from an existing spiral pump is used to carryout validation of the code. (author)

  8. Simulating Biomass Fast Pyrolysis at the Single Particle Scale

    Energy Technology Data Exchange (ETDEWEB)

    Ciesielski, Peter [National Renewable Energy Laboratory (NREL); Wiggins, Gavin [ORNL; Daw, C Stuart [ORNL; Jakes, Joseph E. [U.S. Forest Service, Forest Products Laboratory, Madison, Wisconsin, USA

    2017-07-01

    Simulating fast pyrolysis at the scale of single particles allows for the investigation of the impacts of feedstock-specific parameters such as particle size, shape, and species of origin. For this reason particle-scale modeling has emerged as an important tool for understanding how variations in feedstock properties affect the outcomes of pyrolysis processes. The origins of feedstock properties are largely dictated by the composition and hierarchical structure of biomass, from the microstructural porosity to the external morphology of milled particles. These properties may be accounted for in simulations of fast pyrolysis by several different computational approaches depending on the level of structural and chemical complexity included in the model. The predictive utility of particle-scale simulations of fast pyrolysis can still be enhanced substantially by advancements in several areas. Most notably, considerable progress would be facilitated by the development of pyrolysis kinetic schemes that are decoupled from transport phenomena, predict product evolution from whole-biomass with increased chemical speciation, and are still tractable with present-day computational resources.

  9. Node-based analysis of species distributions

    DEFF Research Database (Denmark)

    Borregaard, Michael Krabbe; Rahbek, Carsten; Fjeldså, Jon

    2014-01-01

    overrepresentation score (SOS) and the geographic node divergence (GND) score, which together combine ecological and evolutionary patterns into a single framework and avoids many of the problems that characterize community phylogenetic methods in current use.This approach goes through each node in the phylogeny...... with case studies on two groups with well-described biogeographical histories: a local-scale community data set of hummingbirds in the North Andes, and a large-scale data set of the distribution of all species of New World flycatchers. The node-based analysis of these two groups generates a set...... of intuitively interpretable patterns that are consistent with current biogeographical knowledge.Importantly, the results are statistically tractable, opening many possibilities for their use in analyses of evolutionary, historical and spatial patterns of species diversity. The method is implemented...

  10. One-Step Nucleic Acid Amplification in Breast Cancer Sentinel Lymph Node: A Single Institutional Experience and a Short Review

    OpenAIRE

    Brambilla, Tatiana; Fiamengo, Barbara; Tinterri, Corrado; Testori, Alberto; Grassi, Massimo Maria; Sciarra, Amedeo; Abbate, Tommaso; Gatzemeier, Wolfgang; Roncalli, Massimo; Di Tommaso, Luca

    2015-01-01

    Sentinel lymph node (SLN) examination is a standard in breast cancer patients, with several methods employed along its 20 years history, the last one represented by one-step nucleic acid amplification (OSNA). The latter is a intra-operative molecular assay searching for CK19 mRNA as a surrogate of metastatic cells. Our 3 years experience with OSNA (1122 patients) showed results overlapping those recorded in the same institution with a morphological evaluation (930 patients) of SLN. In detail,...

  11. Renal malignant solitary fibrous tumor with single lymph node involvement: report of unusual metastasis and review of the literature

    Directory of Open Access Journals (Sweden)

    Mearini E

    2014-05-01

    Full Text Available Ettore Mearini,1 Giovanni Cochetti,1 Francesco Barillaro,1 Sonia Fatigoni,2 Fausto Roila2 1Department of Medical-Surgical Specialties and Public Health, Division of Urological Andrological Surgery and Minimally Invasive Techniques, University of Perugia, Terni, Italy; 2Medical Oncology, S Maria Hospital, Terni, Italy Abstract: Solitary fibrous tumors are rare mesenchymal spindle cell neoplasms that are usually found in the pleura. The kidneys are an uncommon site and only few cases of renal solitary fibrous tumor exhibit malignant behavior metastasizing to the liver, lung, and bone through the hematogenous pathway. Purpose: To describe the first case of lymph node metastasis from renal solitary fibrous tumor in order to increase the knowledge about the malignant behavior of these tumors. Patients and methods: A 19-year-old female patient had intermittent hematuria for several months without flank pain or other symptoms. A chest and abdomen CT scan was performed and showed a multi-lobed bulky solid mass of 170 × 98 × 120 mm in the left kidney. One day before the surgery, the left renal artery was catheterized and the kidney embolization was performed using a Haemostatic Absorbable Gelatin Sponge and polyvinyl alcohol. We then performed a radical nephrectomy with hilar, para-aortic, and inter-aortocaval lymphadenectomy. Results: Estimated intraoperative blood loss was 200 mL and the operative time was 100 minutes. No postoperative complications occurred. The hospital stay was 7 days long. The histological examination was malignant solitary fibrous tumor of the kidney. Cancerous tissue showed cellular atypia, with an increased mitotic index (up to 7 × 10 hpf. Immunohistochemical analysis showed positive results for CD34, BCL2, partial expression of HBME1, and occasionally of synaptophysin. Histological evaluation confirmed the presence of metastasis in one hilar node. The patient did not receive any other therapy. At 30-month follow-up, the

  12. Prediction of sentinel lymph node status using single-photon emission computed tomography (SPECT)/computed tomography (CT) imaging of breast cancer.

    Science.gov (United States)

    Tomiguchi, Mai; Yamamoto-Ibusuki, Mutsuko; Yamamoto, Yutaka; Fujisue, Mamiko; Shiraishi, Shinya; Inao, Touko; Murakami, Kei-ichi; Honda, Yumi; Yamashita, Yasuyuki; Iyama, Ken-ichi; Iwase, Hirotaka

    2016-02-01

    Single-photon emission computed tomography (SPECT)/computed tomography (CT) improves the anatomical identification of sentinel lymph nodes (SNs). We aimed to evaluate the possibility of predicting the SN status using SPECT/CT. SN mapping using a SPECT/CT system was performed in 381 cases of clinically node-negative, operable invasive breast cancer. We evaluated and compared the values of SN mapping on SPECT/CT, the findings of other modalities and clinicopathological factors in predicting the SN status. Patients with SNs located in the Level I area were evaluated. Of the 355 lesions (94.8 %) assessed, six cases (1.6 %) were not detected using any imaging method. According to the final histological diagnosis, 298 lesions (78.2 %) were node negative and 83 lesions (21.7 %) were node positive. The univariate analysis showed that SN status was significantly correlated with the number of SNs detected on SPECT/CT in the Level I area (P = 0.0048), total number of SNs detected on SPECT/CT (P = 0.011), findings of planar lymphoscintigraphy (P = 0.011) and findings of a handheld gamma probe during surgery (P = 0.012). According to the multivariate analysis, the detection of multiple SNs on SPECT/CT imaging helped to predict SN metastasis. The number of SNs located in the Level I area detected using the SPECT/CT system may be a predictive factor for SN metastasis.

  13. Development and Validation of the Single Item Narcissism Scale (SINS)

    Science.gov (United States)

    Konrath, Sara; Meier, Brian P.; Bushman, Brad J.

    2014-01-01

    Main Objectives The narcissistic personality is characterized by grandiosity, entitlement, and low empathy. This paper describes the development and validation of the Single Item Narcissism Scale (SINS). Although the use of longer instruments is superior in most circumstances, we recommend the SINS in some circumstances (e.g. under serious time constraints, online studies). Methods In 11 independent studies (total N = 2,250), we demonstrate the SINS' psychometric properties. Results The SINS is significantly correlated with longer narcissism scales, but uncorrelated with self-esteem. It also has high test-retest reliability. We validate the SINS in a variety of samples (e.g., undergraduates, nationally representative adults), intrapersonal correlates (e.g., positive affect, depression), and interpersonal correlates (e.g., aggression, relationship quality, prosocial behavior). The SINS taps into the more fragile and less desirable components of narcissism. Significance The SINS can be a useful tool for researchers, especially when it is important to measure narcissism with constraints preventing the use of longer measures. PMID:25093508

  14. Development and validation of the Single Item Narcissism Scale (SINS.

    Directory of Open Access Journals (Sweden)

    Sara Konrath

    Full Text Available MAIN OBJECTIVES: The narcissistic personality is characterized by grandiosity, entitlement, and low empathy. This paper describes the development and validation of the Single Item Narcissism Scale (SINS. Although the use of longer instruments is superior in most circumstances, we recommend the SINS in some circumstances (e.g. under serious time constraints, online studies. METHODS: In 11 independent studies (total N = 2,250, we demonstrate the SINS' psychometric properties. RESULTS: The SINS is significantly correlated with longer narcissism scales, but uncorrelated with self-esteem. It also has high test-retest reliability. We validate the SINS in a variety of samples (e.g., undergraduates, nationally representative adults, intrapersonal correlates (e.g., positive affect, depression, and interpersonal correlates (e.g., aggression, relationship quality, prosocial behavior. The SINS taps into the more fragile and less desirable components of narcissism. SIGNIFICANCE: The SINS can be a useful tool for researchers, especially when it is important to measure narcissism with constraints preventing the use of longer measures.

  15. Laparoscopic and open postchemotherapy retroperitoneal lymph node dissection in patients with advanced testicular cancer – a single center analysis

    Directory of Open Access Journals (Sweden)

    Busch Jonas

    2012-05-01

    Full Text Available Abstract Background The open approach represents the gold standard for postchemotherapy retroperitoneal lymph node dissection (O-PCLND in patients with residual testicular cancer. We analyzed laparoscopic postchemotherapy retroperitoneal lymph node dissection (L-PCLND and O-PCLND at our institution. Methods Patients underwent either L-PCLND (n = 43 or O-PCLND (n = 24. Categorical and continuous variables were compared using the Fisher exact test and Mann–Whitney U test respectively. Overall survival was evaluated with the log-rank test. Results Primary histology was embryonal cell carcinomas (18 patients, pure seminoma (2 cases and mixed NSGCTs (47 patients. According to the IGCCCG patients were categorized into “good”, “intermediate” and “poor prognosis” disease in 55.2%, 14.9% and 20.8%, respectively. Median operative time for L-PCLND was 212 min and 232 min for O-PCLND (p = 0.256. Median postoperative duration of drainage and hospital stay was shorter after L-PCLND (0.0 vs. 3.5 days; p 500 ml was almost equally distributed (8.6% vs. 14.2%: p = 0.076. No significant differences were observed for injuries of major vessels and postoperative complications (p = 0.758; p = 0.370. Tumor recurrence occurred in 8.6% following L-PCLND and in 14.2% following O-PCLND with a mean disease-free survival of 76.6 and 89.2 months, respectively. Overall survival was 83.3 and 95.0 months for L-PCNLD and O-PCLND, respectively (p = 0.447. Conclusions L-PCLND represents a safe surgical option for well selected patients at an experienced center.

  16. Single-field consistency relations of large scale structure

    International Nuclear Information System (INIS)

    Creminelli, Paolo; Noreña, Jorge; Simonović, Marko; Vernizzi, Filippo

    2013-01-01

    We derive consistency relations for the late universe (CDM and ΛCDM): relations between an n-point function of the density contrast δ and an (n+1)-point function in the limit in which one of the (n+1) momenta becomes much smaller than the others. These are based on the observation that a long mode, in single-field models of inflation, reduces to a diffeomorphism since its freezing during inflation all the way until the late universe, even when the long mode is inside the horizon (but out of the sound horizon). These results are derived in Newtonian gauge, at first and second order in the small momentum q of the long mode and they are valid non-perturbatively in the short-scale δ. In the non-relativistic limit our results match with [1]. These relations are a consequence of diffeomorphism invariance; they are not satisfied in the presence of extra degrees of freedom during inflation or violation of the Equivalence Principle (extra forces) in the late universe

  17. Failure in the detection of the sentinel lymph node with a combined technique of radioactive tracer and blue dye in a patient with cancer of the vulva and a single positive lymph node

    NARCIS (Netherlands)

    Fons, G.; ter Rahe, B.; Sloof, G.; de Hullu, J.; van der Velden, J.

    2004-01-01

    Background. In early stage vulvar cancer, the sentinel lymph node procedure with a radioactive tracer appears to be a promising new diagnostic tool to predict lymph node status. No detection failures have been published so far in vulvar cancer. We recently experienced failure in the detection of the

  18. Failure in the detection of the sentinel lymph node with a combined technique of radioactive tracer and blue dye in a patient with cancer of the vulva and a single positive lymph node

    NARCIS (Netherlands)

    Fons, G; ter Rahe, B; Sloof, G; de Hullu, J; van der Velden, J

    Background. In early stage vulvar cancer, the sentinel lymph node procedure with a radioactive tracer appears to be a promising new diagnostic tool to predict lymph node status. No detection failures have been published so far in vulvar cancer. We recently experienced failure in the detection of the

  19. One-Step Nucleic Acid Amplification in Breast Cancer Sentinel Lymph Node: A Single Institutional Experience and a Short Review.

    Science.gov (United States)

    Brambilla, Tatiana; Fiamengo, Barbara; Tinterri, Corrado; Testori, Alberto; Grassi, Massimo Maria; Sciarra, Amedeo; Abbate, Tommaso; Gatzemeier, Wolfgang; Roncalli, Massimo; Di Tommaso, Luca

    2015-01-01

    Sentinel lymph node (SLN) examination is a standard in breast cancer patients, with several methods employed along its 20 years history, the last one represented by one-step nucleic acid amplification (OSNA). The latter is a intra-operative molecular assay searching for CK19 mRNA as a surrogate of metastatic cells. Our 3 years experience with OSNA (1122 patients) showed results overlapping those recorded in the same institution with a morphological evaluation (930 patients) of SLN. In detail, the data of OSNA were almost identical to those observed with standard post-operative procedure in terms of patients with positive SLN (30%) and micrometastatic/macrometastatic involvement of SLN (respectively, 38-45 and 62-55%). By contrast, when OSNA was compared to the standard intraoperatory procedure, it was superior in terms of accuracy, prompting the use of this molecular assay as a very valid, and reproducible for intra-operative evaluation of SLN. Further possibilities prompting the use of OSNA range from adhesion to quality control programs, saving of medical time, ability to predict, during surgery, additional nodal metastasis, and molecular bio-banking.

  20. ONE STEP NUCLEIC ACID AMPLIFICATION IN BREAST CANCER SENTINEL LYMPH NODE.A SINGLE INSTITUTIONAL EXPERIENCE AND A SHORT REVIEW.

    Directory of Open Access Journals (Sweden)

    Tatiana eBrambilla

    2015-06-01

    Full Text Available Sentinel lymph node (SLN examination is a standard in breast cancer patients, with several methods employed along its 20-years history, the last one represented by OSNA. The latter is a intra-operative molecular assay searching for CK19 mRNA as a surrogate of metastatic cells. Our 3-years experience with OSNA (1122 patients showed results overlapping those recorded in the same Institution with a morphological evaluation (930 patients of SLN. In detail the data of OSNA were almost identical to those observed with standard post-operative procedure in terms of patients with positive SLN (30% and micrometastatic/macrometastatic involvement of SLN (respectively 38-45% and 62-55%. By contrast when OSNA was compared to the standard intra-operatory procedure it was superior in terms of accuracy, prompting the use of this molecular assay as a very valid and reproducible for intra-operative evaluation of SLN.Further possibilities prompting the use of OSNA range from adhesion to quality control programs, saving of medical time, ability to predict, during surgery, additional nodal metatastis and molecular bio-banking.

  1. Cortical actin nodes: Their dynamics and recruitment of podosomal proteins as revealed by super-resolution and single-molecule microscopy

    Science.gov (United States)

    Shirai, Yuki M.; Tsunoyama, Taka A.; Hiramoto-Yamaki, Nao; Hirosawa, Koichiro M.; Shibata, Akihiro C. E.; Kondo, Kenichi; Tsurumune, Atsushi; Ishidate, Fumiyoshi; Kusumi, Akihiro

    2017-01-01

    Electron tomography of the plasma membrane (PM) identified several layers of cortical actin meshwork running parallel to the PM cytoplasmic surface throughout the PM. Here, cortical actin structures and dynamics were examined in living cells, using super-resolution microscopy, with (x,y)- and z-resolutions of ~140 and ~400 nm, respectively, and single-molecule imaging. The super-resolution microscopy identified sub-micron-sized actin clusters that appeared identical by both phalloidin post-fixation staining and Lifeact-mGFP expression followed by fixation, and therefore, these actin clusters were named “actin-pl-clusters”. In live cells, the actin-pl-clusters visualized by Lifeact-mGFP linked two or more actin filaments in the fine actin meshwork, acting as a node of the meshwork, and dynamically moved on/along the meshwork in a myosin II-dependent manner. Their formation depended on the Arp2/3 activities, suggesting that the movements could involve both the myosin motor activity and actin polymerization-depolymerization. The actin-pl-clusters differ from the actin nodes/asters found previously after latrunculin treatments, since myosin II and filamin A were not colocalized with the actin-pl-clusters, and the actin-pl-clusters were much smaller than the previously reported nodes/asters. The Lifeact linked to a fluorescently-labeled transmembrane peptide from syntaxin4 (Lifeact-TM) expressed in the PM exhibited temporary immobilization in the PM regions on which actin-pl-clusters and stress fibers were projected, showing that ≥66% of actin-pl-clusters and 89% of stress fibers were located in close proximity (within 3.5 nm) to the PM cytoplasmic surface. Podosome-associated cytoplasmic proteins, Tks4, Tks5, cortactin, and N-WASP, were transiently recruited to actin-pl-clusters, and thus, we propose that actin-pl-clusters also represent “actin podosome-like clusters”. PMID:29190677

  2. Cervical Lymph Node Metastases From Unknown Primary Cancer: A Single-Institution Experience With Intensity-Modulated Radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Villeneuve, Hugo, E-mail: hugo.villeneuve@umontreal.ca [Department of Radiation Oncology, Centre hospitalier de l' Universite de Montreal, Montreal, QC (Canada); Despres, Philippe; Fortin, Bernard; Filion, Edith; Donath, David [Department of Radiation Oncology, Centre hospitalier de l' Universite de Montreal, Montreal, QC (Canada); Soulieres, Denis [Department of Medical Oncology, Centre hospitalier de l' Universite de Montreal, Montreal, QC (Canada); Guertin, Louis; Ayad, Tarek; Christopoulos, Apostolos [Department of Head and Neck Surgery, Centre hospitalier de l' Universite de Montreal, Montreal, QC (Canada); Nguyen-Tan, Phuc Felix [Department of Radiation Oncology, Centre hospitalier de l' Universite de Montreal, Montreal, QC (Canada)

    2012-04-01

    Purpose: To determine the effectiveness and rate of complications of intensity-modulated radiotherapy (IMRT) in the treatment of cervical lymph node metastases from unknown primary cancer. Methods and Materials: Between February 2005 and November 2008, 25 patients with an unknown primary cancer underwent IMRT, with a median radiation dose of 70 Gy. The bilateral neck and ipsilateral putative pharyngeal mucosa were included in the target volume. All patients had squamous cell carcinoma, except for 1 patient who had adenosquamous differentiation. They were all treated with curative intent. Of the 25 included patients, 20 were men and 5 were women, with a median age of 54 years. Of these patients, 3 had Stage III, 18 had Stage IVa, and 4 had Stage IVb. Of the 25 patients, 18 (72%) received platinum-based chemotherapy in a combined-modality setting. Neck dissection was reserved for residual disease after definitive IMRT. Overall survival, disease-free survival, and locoregional control were calculated using the Kaplan-Meier method. Results: With a median follow-up of 38 months, the overall survival, disease-free survival, and locoregional control rates were all 100% at 3 years. No occurrence of primary cancer was observed during the follow-up period. The reported rates of xerostomia reduced with the interval from the completion of treatment. Nine patients (36%) reported Grade 2 or greater xerostomia at 6 months, and only 2 (8%) of them reported the same grade of salivary function toxicity after 24 months of follow-up. Conclusion: In our institution, IMRT for unknown primary cancer has provided good overall and disease-free survival in all the patients with an acceptable rate of complications. IMRT allowed us to address the bilateral neck and ipsilateral putative pharyngeal mucosa with minimal late salivary function toxicity. The use of concurrent chemotherapy and IMRT for more advanced disease led to good clinical results with reasonable toxicities.

  3. Comparison of Single-Photon Emission Computed Tomography-Computed Tomography (SPECT/CT) and Conventional Planar Lymphoscintigraphy for Sentinel Node Localization in Patients with Cutaneous Malignancies.

    Science.gov (United States)

    Doepker, Matthew P; Yamamoto, Maki; Applebaum, Matthew A; Patel, Nupur U; Jaime Montilla-Soler, M; Sarnaik, Amod A; Wayne Cruse, C; Sondak, Vernon K; Zager, Jonathan S

    2017-02-01

    Accurate preoperative lymphoscintigraphy is vital to performing sentinel lymph node biopsy (SLNB) for cutaneous malignancies. Potential advantages of single-photon emission computed tomography with integrated computed tomography (SPECT/CT) include the ability to readily identify aberrant drainage patterns as well as provide the surgeon with three-dimensional anatomic landmarks not seen on conventional planar lymphoscintigraphy (PLS). Patients with cutaneous malignancies who underwent SLNB with preoperative imaging using both SPECT/CT and PLS from 2011 to 2014 were identified. Both SPECT/CT and PLS were obtained in 351 patients (median age, 69 years; range, 5-94 years) with cutaneous malignancies (melanoma = 300, Merkel cell carcinoma = 33, squamous cell carcinoma = 8, other = 10) after intradermal injection of 99m technetium sulfur colloid (median dose 300 µCi). A mean of 4.3 hot spots were identified on SPECT/CT compared to 3.0 on PLS (p CT and PLS, while 172 (49 %) had additional hot spots identified on SPECT/CT compared to only 24 (6.8 %) additional on PLS. SPECT/CT demonstrated additional nodal basins in 103 patients (29.4 %), compared to only 11 patients (3.1 %) with additional basins on PLS. SPECT/CT is a useful adjunct that can help with sentinel node localization in challenging cases. It identified additional hot spots not seen on PLS in almost 50 % of patients. Because PLS identified hot spots not seen on SPECT/CT in 6.8 % of patients, we recommend using both modalities jointly. Long-term follow-up will be required to validate the clinical significance of the additional hot spots identified by SPECT/CT.

  4. Dynamic Voltage-Frequency and Workload Joint Scaling Power Management for Energy Harvesting Multi-Core WSN Node SoC

    Directory of Open Access Journals (Sweden)

    Xiangyu Li

    2017-02-01

    Full Text Available This paper proposes a scheduling and power management solution for energy harvesting heterogeneous multi-core WSN node SoC such that the system continues to operate perennially and uses the harvested energy efficiently. The solution consists of a heterogeneous multi-core system oriented task scheduling algorithm and a low-complexity dynamic workload scaling and configuration optimization algorithm suitable for light-weight platforms. Moreover, considering the power consumption of most WSN applications have the characteristic of data dependent behavior, we introduce branches handling mechanism into the solution as well. The experimental result shows that the proposed algorithm can operate in real-time on a lightweight embedded processor (MSP430, and that it can make a system do more valuable works and make more than 99.9% use of the power budget.

  5. Atomic-Scale Control of Electron Transport through Single Molecules

    DEFF Research Database (Denmark)

    Wang, Y. F.; Kroger, J.; Berndt, R.

    2010-01-01

    Tin-phthalocyanine molecules adsorbed on Ag(111) were contacted with the tip of a cryogenic scanning tunneling microscope. Orders-of-magnitude variations of the single-molecule junction conductance were achieved by controllably dehydrogenating the molecule and by modifying the atomic structure...

  6. Microarray-based large scale detection of single feature ...

    Indian Academy of Sciences (India)

    2015-12-08

    Dec 8, 2015 ... mental stages was used to identify single feature polymorphisms (SFPs). ... on a high-density oligonucleotide expression array in which. ∗ ..... The sign (+/−) with SFPs indicates direction of polymorphism. In the. (−) sign (i.e. ...

  7. Vision for single flux quantum very large scale integrated technology

    International Nuclear Information System (INIS)

    Silver, Arnold; Bunyk, Paul; Kleinsasser, Alan; Spargo, John

    2006-01-01

    Single flux quantum (SFQ) electronics is extremely fast and has very low on-chip power dissipation. SFQ VLSI is an excellent candidate for high-performance computing and other applications requiring extremely high-speed signal processing. Despite this, SFQ technology has generally not been accepted for system implementation. We argue that this is due, at least in part, to the use of outdated tools to produce SFQ circuits and chips. Assuming the use of tools equivalent to those employed in the semiconductor industry, we estimate the density of Josephson junctions, circuit speed, and power dissipation that could be achieved with SFQ technology. Today, CMOS lithography is at 90-65 nm with about 20 layers. Assuming equivalent technology, aggressively increasing the current density above 100 kA cm -2 to achieve junction speeds approximately 1000 GHz, and reducing device footprints by converting device profiles from planar to vertical, one could expect to integrate about 250 M Josephson junctions cm -2 into SFQ digital circuits. This should enable circuit operation with clock frequencies above 200 GHz and place approximately 20 K gates within a radius of one clock period. As a result, complete microprocessors, including integrated memory registers, could be fabricated on a single chip

  8. Vision for single flux quantum very large scale integrated technology

    Energy Technology Data Exchange (ETDEWEB)

    Silver, Arnold [Northrop Grumman Space Technology, One Space Park, Redondo Beach, CA 90278 (United States); Bunyk, Paul [Northrop Grumman Space Technology, One Space Park, Redondo Beach, CA 90278 (United States); Kleinsasser, Alan [Jet Propulsion Laboratory, 4800 Oak Grove Drive, Pasadena, CA 91109-8099 (United States); Spargo, John [Northrop Grumman Space Technology, One Space Park, Redondo Beach, CA 90278 (United States)

    2006-05-15

    Single flux quantum (SFQ) electronics is extremely fast and has very low on-chip power dissipation. SFQ VLSI is an excellent candidate for high-performance computing and other applications requiring extremely high-speed signal processing. Despite this, SFQ technology has generally not been accepted for system implementation. We argue that this is due, at least in part, to the use of outdated tools to produce SFQ circuits and chips. Assuming the use of tools equivalent to those employed in the semiconductor industry, we estimate the density of Josephson junctions, circuit speed, and power dissipation that could be achieved with SFQ technology. Today, CMOS lithography is at 90-65 nm with about 20 layers. Assuming equivalent technology, aggressively increasing the current density above 100 kA cm{sup -2} to achieve junction speeds approximately 1000 GHz, and reducing device footprints by converting device profiles from planar to vertical, one could expect to integrate about 250 M Josephson junctions cm{sup -2} into SFQ digital circuits. This should enable circuit operation with clock frequencies above 200 GHz and place approximately 20 K gates within a radius of one clock period. As a result, complete microprocessors, including integrated memory registers, could be fabricated on a single chip.

  9. Sentinel node biopsy in penile cancer

    DEFF Research Database (Denmark)

    Jakobsen, J. K.; Krarup, K. P.; Sommer, P.

    2015-01-01

    INTRODUCTION & OBJECTIVES: Nodal involvement is a strong prognosticator in penile cancer and lymph node staging is crucial. Sentinel node biopsy (SNB) has proven a useful staging tool with few complications, but evidence rely mostly on single institution publications with a short follow-up. In th......INTRODUCTION & OBJECTIVES: Nodal involvement is a strong prognosticator in penile cancer and lymph node staging is crucial. Sentinel node biopsy (SNB) has proven a useful staging tool with few complications, but evidence rely mostly on single institution publications with a short follow...... died from complications. CONCLUSIONS: To our knowledge, this is the first complete national study on sentinel node biopsy. Penile cancer sentinel node biopsy with a close follow-up is a reliable lymph node staging and has few complications in a national multicentre setting. Inguinal lymph node...

  10. One node driving synchronisation

    Science.gov (United States)

    Wang, Chengwei; Grebogi, Celso; Baptista, Murilo S.

    2015-12-01

    Abrupt changes of behaviour in complex networks can be triggered by a single node. This work describes the dynamical fundamentals of how the behaviour of one node affects the whole network formed by coupled phase-oscillators with heterogeneous coupling strengths. The synchronisation of phase-oscillators is independent of the distribution of the natural frequencies, weakly depends on the network size, but highly depends on only one key oscillator whose ratio between its natural frequency in a rotating frame and its coupling strength is maximum. This result is based on a novel method to calculate the critical coupling strength with which the phase-oscillators emerge into frequency synchronisation. In addition, we put forward an analytical method to approximately calculate the phase-angles for the synchronous oscillators.

  11. The Single-Item Math Anxiety Scale: An Alternative Way of Measuring Mathematical Anxiety

    Science.gov (United States)

    Núñez-Peña, M. Isabel; Guilera, Georgina; Suárez-Pellicioni, Macarena

    2014-01-01

    This study examined whether the Single-Item Math Anxiety Scale (SIMA), based on the item suggested by Ashcraft, provided valid and reliable scores of mathematical anxiety. A large sample of university students (n = 279) was administered the SIMA and the 25-item Shortened Math Anxiety Rating Scale (sMARS) to evaluate the relation between the scores…

  12. Electrochemistry of single molecules and biomolecules, molecular scale nanostructures, and low-dimensional systems

    DEFF Research Database (Denmark)

    Nazmutdinov, Renat R.; Zinkicheva, Tamara T.; Zinkicheva, Tamara T.

    2018-01-01

    Electrochemistry at ultra-small scales, where even the single molecule or biomolecule can be characterized and manipulated, is on the way to a consolidated status. At the same time molecular electrochemistry is expanding into other areas of sophisticated nano- and molecular scale systems includin...... molecular scale metal and semiconductor nanoparticles (NPs) and other nanostructures, e.g. nanotubes, “nanoflowers” etc.. The new structures offer both new electronic properties and highly confined novel charge transfer environments....

  13. Node-pair reliability of network systems with small distances between adjacent nodes

    International Nuclear Information System (INIS)

    Malinowski, Jacek

    2007-01-01

    A new method for computing the node-pair reliability of network systems modeled by random graphs with nodes arranged in sequence is presented. It is based on a recursive algorithm using the 'sliding window' technique, the window being composed of several consecutive nodes. In a single step, the connectivity probabilities for all nodes included in the window are found. Subsequently, the window is moved one node forward. This process is repeated until, in the last step, the window reaches the terminal node. The connectivity probabilities found at that point are used to compute the node-pair reliability of the network system considered. The algorithm is designed especially for graphs with small distances between adjacent nodes, where the distance between two nodes is defined as the absolute value of the difference between the nodes' numbers. The maximal distance between any two adjacent nodes is denoted by Γ(G), where G symbolizes a random graph. If Γ(G)=2 then the method can be applied for directed as well as undirected graphs whose nodes and edges are subject to failure. This is important in view of the fact that many algorithms computing network reliability are designed for graphs with failure-prone edges and reliable nodes. If Γ(G)=3 then the method's applicability is limited to undirected graphs with reliable nodes. The main asset of the presented algorithms is their low numerical complexity-O(n), where n denotes the number of nodes

  14. Delving Deep into Multiscale Pedestrian Detection via Single Scale Feature Maps

    Directory of Open Access Journals (Sweden)

    Xinchuan Fu

    2018-04-01

    Full Text Available The standard pipeline in pedestrian detection is sliding a pedestrian model on an image feature pyramid to detect pedestrians of different scales. In this pipeline, feature pyramid construction is time consuming and becomes the bottleneck for fast detection. Recently, a method called multiresolution filtered channels (MRFC was proposed which only used single scale feature maps to achieve fast detection. However, there are two shortcomings in MRFC which limit its accuracy. One is that the receptive field correspondence in different scales is weak. Another is that the features used are not scale invariance. In this paper, two solutions are proposed to tackle with the two shortcomings respectively. Specifically, scale-aware pooling is proposed to make a better receptive field correspondence, and soft decision tree is proposed to relive scale variance problem. When coupled with efficient sliding window classification strategy, our detector achieves fast detecting speed at the same time with state-of-the-art accuracy.

  15. Single Image Super-Resolution Based on Multi-Scale Competitive Convolutional Neural Network.

    Science.gov (United States)

    Du, Xiaofeng; Qu, Xiaobo; He, Yifan; Guo, Di

    2018-03-06

    Deep convolutional neural networks (CNNs) are successful in single-image super-resolution. Traditional CNNs are limited to exploit multi-scale contextual information for image reconstruction due to the fixed convolutional kernel in their building modules. To restore various scales of image details, we enhance the multi-scale inference capability of CNNs by introducing competition among multi-scale convolutional filters, and build up a shallow network under limited computational resources. The proposed network has the following two advantages: (1) the multi-scale convolutional kernel provides the multi-context for image super-resolution, and (2) the maximum competitive strategy adaptively chooses the optimal scale of information for image reconstruction. Our experimental results on image super-resolution show that the performance of the proposed network outperforms the state-of-the-art methods.

  16. Level-statistics in Disordered Systems: A single parametric scaling and Connection to Brownian Ensembles

    OpenAIRE

    Shukla, Pragya

    2004-01-01

    We find that the statistics of levels undergoing metal-insulator transition in systems with multi-parametric Gaussian disorders and non-interacting electrons behaves in a way similar to that of the single parametric Brownian ensembles \\cite{dy}. The latter appear during a Poisson $\\to$ Wigner-Dyson transition, driven by a random perturbation. The analogy provides the analytical evidence for the single parameter scaling of the level-correlations in disordered systems as well as a tool to obtai...

  17. Single-stage micro-scale solvent extraction in parallel microbore tubes using MDIMJ

    International Nuclear Information System (INIS)

    Darekar, Mayur; Singh, K.K.; Joshi, J.M.; Mukhopadhyay, S.; Shenoy, K.T.

    2016-01-01

    Single-stage micro-scale solvent extraction of U(VI) from simulated lean streams is explored using micro-scale contactor comprising of a MDIMJ (Monoblock Distributor with Integrated Microfluidic Junction) and PTFE microbore tubes. 30% (v/v) TBP in dodecane has been used as the extracting phase. The objective of the study is to demonstrate numbering up approach for scale-up of micro-scale extraction using indigenously conceptualized and fabricated MDIMJ. First the performance of MIDIMJ for equal flow distribution is tested. Then the effects of inlet flow rate and O/A ratio on stage efficiency and percentage extraction are studied. The experiments show that it is easy to scale-up single-stage micro-scale solvent extraction by using MDIMJ for numbering up approach. Maximum capacity tested is 4.8 LPH. With O/A = 2/1, more than 90% extraction is achieved in a very short contact time of less than 3s. The study thus demonstrates possibility of process intensification and easy scale-up of micro-scale solvent extraction

  18. Industrial-scale separation of high-purity single-chirality single-wall carbon nanotubes for biological imaging

    Science.gov (United States)

    Yomogida, Yohei; Tanaka, Takeshi; Zhang, Minfang; Yudasaka, Masako; Wei, Xiaojun; Kataura, Hiromichi

    2016-01-01

    Single-chirality, single-wall carbon nanotubes are desired due to their inherent physical properties and performance characteristics. Here, we demonstrate a chromatographic separation method based on a newly discovered chirality-selective affinity between carbon nanotubes and a gel containing a mixture of the surfactants. In this system, two different selectivities are found: chiral-angle selectivity and diameter selectivity. Since the chirality of nanotubes is determined by the chiral angle and diameter, combining these independent selectivities leads to high-resolution single-chirality separation with milligram-scale throughput and high purity. Furthermore, we present efficient vascular imaging of mice using separated single-chirality (9,4) nanotubes. Due to efficient absorption and emission, blood vessels can be recognized even with the use of ∼100-fold lower injected dose than the reported value for pristine nanotubes. Thus, 1 day of separation provides material for up to 15,000 imaging experiments, which is acceptable for industrial use. PMID:27350127

  19. A single gene (yes controls pigmentation of eyes and scales in Heliothis virescens

    Directory of Open Access Journals (Sweden)

    Thomas M. Brown

    2001-02-01

    Full Text Available A yellow-eyed mutant was discovered in a strain of Heliothis virescens, the tobacco budworm, that already exhibited a mutation for yellow scale, y. We investigated the inheritance of these visible mutations as candidate markers for transgenesis. Yellow eye was controlled by a single, recessive, autosomal factor, the same type of inheritance previously known for y. Presence of the recombinant mutants with yellow scales with wild type eyes in test crosses indicated independent segregation of genes for these traits. The recombinant class with wild type scales and yellow eyes was completely absent and there was a corresponding increase of the double mutant parental class having yellow scales and yellow eyes. These results indicated that a single factor for yellow eye also controls yellow scales independently of y. This gene was named yes, for yellow eye and scale. We hypothesize that yes controls both eye and scale color through a deficiency in transport of pigment precursors in both the ommochrome and melanin pathways. The unlinked gene y likely controls an enzyme affecting the melanin pathway only. Both y and yes segregated independently of AceIn, acetylcholinesterase insensitivity, and sodium channel hscp, which are genes related to insecticide resistance.

  20. Heart rate detection from single-foot plantar bioimpedance measurements in a weighing scale.

    Science.gov (United States)

    Diaz, Delia H; Casas, Oscar; Pallas-Areny, Ramon

    2010-01-01

    Electronic bathroom scales are an easy-to-use, affordable mean to measure physiological parameters in addition to body weight. They have been proposed to obtain the ballistocardiogram (BCG) and derive from it the heart rate, cardiac output and systolic blood pressure. Therefore, weighing scales may suit intermittent monitoring in e-health and patient screening. Scales intended for bioelectrical impedance analysis (BIA) have also been proposed to estimate the heart rate by amplifying the pulsatile impedance component superimposed on the basal impedance. However, electronic weighing scales cannot easily obtain the BCG from people that have a single leg neither are bioimpedance measurements between both feet recommended for people wearing a pacemaker or other electronic implants, neither for pregnant women. We propose a method to detect the heart rate (HR) from bioimpedance measured in a single foot while standing on an bathroom weighting scale intended for BIA. The electrodes built in the weighing scale are used to apply a 50 kHz voltage between the outer electrode pair and to measure the drop in voltage across the inner electrode pair. The agreement with the HR simultaneously obtained from the ECG is excellent. We have also compared the drop in voltage across the waist and the thorax with that obtained when measuring bioimpedance between both feet to compare the possible risk of the proposed method to that of existing BIA scales.

  1. Role of optometry school in single day large scale school vision testing

    Science.gov (United States)

    Anuradha, N; Ramani, Krishnakumar

    2015-01-01

    Background: School vision testing aims at identification and management of refractive errors. Large-scale school vision testing using conventional methods is time-consuming and demands a lot of chair time from the eye care professionals. A new strategy involving a school of optometry in single day large scale school vision testing is discussed. Aim: The aim was to describe a new approach of performing vision testing of school children on a large scale in a single day. Materials and Methods: A single day vision testing strategy was implemented wherein 123 members (20 teams comprising optometry students and headed by optometrists) conducted vision testing for children in 51 schools. School vision testing included basic vision screening, refraction, frame measurements, frame choice and referrals for other ocular problems. Results: A total of 12448 children were screened, among whom 420 (3.37%) were identified to have refractive errors. 28 (1.26%) children belonged to the primary, 163 to middle (9.80%), 129 (4.67%) to secondary and 100 (1.73%) to the higher secondary levels of education respectively. 265 (2.12%) children were referred for further evaluation. Conclusion: Single day large scale school vision testing can be adopted by schools of optometry to reach a higher number of children within a short span. PMID:25709271

  2. Anti-control of chaos of single time-scale brushless DC motor.

    Science.gov (United States)

    Ge, Zheng-Ming; Chang, Ching-Ming; Chen, Yen-Sheng

    2006-09-15

    Anti-control of chaos of single time-scale brushless DC motors is studied in this paper. In order to analyse a variety of periodic and chaotic phenomena, we employ several numerical techniques such as phase portraits, bifurcation diagrams and Lyapunov exponents. Anti-control of chaos can be achieved by adding an external constant term or an external periodic term.

  3. Evaluating Change in Behavioral Preferences: Multidimensional Scaling Single-Ideal Point Model

    Science.gov (United States)

    Ding, Cody

    2016-01-01

    The purpose of the article is to propose a multidimensional scaling single-ideal point model as a method to evaluate changes in individuals' preferences under the explicit methodological framework of behavioral preference assessment. One example is used to illustrate the approach for a clear idea of what this approach can accomplish.

  4. Atomic-scale structure of single-layer MoS2 nanoclusters

    DEFF Research Database (Denmark)

    Helveg, S.; Lauritsen, J. V.; Lægsgaard, E.

    2000-01-01

    We have studied using scanning tunneling microscopy (STM) the atomic-scale realm of molybdenum disulfide (MoS2) nanoclusters, which are of interest as a model system in hydrodesulfurization catalysis. The STM gives the first real space images of the shape and edge structure of single-layer MoS2...

  5. A psychometric comparison of three scales and a single-item measure to assess sexual satisfaction.

    Science.gov (United States)

    Mark, Kristen P; Herbenick, Debby; Fortenberry, J Dennis; Sanders, Stephanie; Reece, Michael

    2014-01-01

    This study was designed to systematically compare and contrast the psychometric properties of three scales developed to measure sexual satisfaction and a single-item measure of sexual satisfaction. The Index of Sexual Satisfaction (ISS), Global Measure of Sexual Satisfaction (GMSEX), and the New Sexual Satisfaction Scale-Short (NSSS-S) were compared to one another and to a single-item measure of sexual satisfaction. Conceptualization of the constructs, distribution of scores, internal consistency, convergent validity, test-retest reliability, and factor structure were compared between the measures. A total of 211 men and 214 women completed the scales and a measure of relationship satisfaction, with 33% (n = 139) of the sample reassessed two months later. All scales demonstrated appropriate distribution of scores and adequate internal consistency. The GMSEX, NSSS-S, and the single-item measure demonstrated convergent validity. Test-retest reliability was demonstrated by the ISS, GMSEX, and NSSS-S, but not the single-item measure. Taken together, the GMSEX received the strongest psychometric support in this sample for a unidimensional measure of sexual satisfaction and the NSSS-S received the strongest psychometric support in this sample for a bidimensional measure of sexual satisfaction.

  6. Large-scale single-chirality separation of single-wall carbon nanotubes by simple gel chromatography

    Science.gov (United States)

    Liu, Huaping; Nishide, Daisuke; Tanaka, Takeshi; Kataura, Hiromichi

    2011-01-01

    Monostructured single-wall carbon nanotubes (SWCNTs) are important in both scientific research and electronic and biomedical applications; however, the bulk separation of SWCNTs into populations of single-chirality nanotubes remains challenging. Here we report a simple and effective method for the large-scale chirality separation of SWCNTs using a single-surfactant multicolumn gel chromatography method utilizing one surfactant and a series of vertically connected gel columns. This method is based on the structure-dependent interaction strength of SWCNTs with an allyl dextran-based gel. Overloading an SWCNT dispersion on the top column results in the adsorption sites of the column becoming fully occupied by the nanotubes that exhibit the strongest interaction with the gel. The unbound nanotubes flow through to the next column, and the nanotubes with the second strongest interaction with the gel are adsorbed in this stage. In this manner, 13 different (n, m) species were separated. Metallic SWCNTs were finally collected as unbound nanotubes because they exhibited the lowest interaction with the gel. PMID:21556063

  7. Preliminary Study of Single-Phase Natural Circulation for Lab-scaled Molten Salt Application

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Yukyung; Kang, Sarah; Kim, In Guk; Seo, Seok Bin; Bang, In Cheol [UNIST, Ulsan (Korea, Republic of); Park, Seong Dae [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-10-15

    Advanced reactors such as MSR (FHR), VHTR and AHTR utilized molten salt as a coolant for efficiency and safety which has advantages in higher heat capacity, lower pumping power and scale compared to liquid metal. It becomes more necessary to study on the characteristics of molten salt. However, due to several characteristics such as high operating temperature, large-scale facility and preventing solidification, satisfying that condition for study has difficulties. Thus simulant fluid was used with scaling method for lab-scale experiment. Scaled experiment enables simulant fluid to simulate fluid mechanics and heat transfer behavior of molten salt on lower operating temperature and reduced scale. In this paper, as a proof test of the scaled experiment, simplified single-phase natural circulation loop was designed in a lab-scale and applied to the passive safety system in advanced reactor in which molten salt is considered as a major coolant of the system. For the application of the improved safety system, prototype was based on the primary loop of the test-scale DRACS, the main passive safety system in FHR, developed at the OSU. For preliminary experiment, single-phase natural circulation under low power was performed. DOWTHERM A and DOWTHERM RP were selected as simulant candidates. Then, study of feasibility with simulant was conducted based on the scaling law for heat transfer characteristics and geometric parameters. Additionally, simulation with MARS code and ANSYS-CFX with the same condition of natural circulation was carried out as verification. For the accurate code simulation, thermo-physical properties of DOWTHERM A and RP were developed and implemented into MARS code. In this study, single-phase natural circulation experiment was performed with simulant oil, DOWTHERM RP, based on the passive safety system of FHR. Feasibility of similarity experiment for molten salt with oil simulant was confirmed by scaling method. In addition, simulation with two

  8. Scaling of F-actin network rheology to probe single filament elasticity and dynamics.

    Science.gov (United States)

    Gardel, M L; Shin, J H; MacKintosh, F C; Mahadevan, L; Matsudaira, P A; Weitz, D A

    2004-10-29

    The linear and nonlinear viscoelastic response of networks of cross-linked and bundled cytoskeletal filaments demonstrates remarkable scaling with both frequency and applied prestress, which helps elucidate the origins of the viscoelasticity. The frequency dependence of the shear modulus reflects the underlying single-filament relaxation dynamics for 0.1-10 rad/sec. Moreover, the nonlinear strain stiffening of such networks exhibits a universal form as a function of prestress; this is quantitatively explained by the full force-extension relation of single semiflexible filaments.

  9. The impact of ordinate scaling on the visual analysis of single-case data.

    Science.gov (United States)

    Dart, Evan H; Radley, Keith C

    2017-08-01

    Visual analysis is the primary method for detecting the presence of treatment effects in graphically displayed single-case data and it is often referred to as the "gold standard." Although researchers have developed standards for the application of visual analysis (e.g., Horner et al., 2005), over- and underestimation of effect size magnitude is not uncommon among analysts. Several characteristics have been identified as potential contributors to these errors; however, researchers have largely focused on characteristics of the data itself (e.g., autocorrelation), paying less attention to characteristics of the graphic display which are largely in control of the analyst (e.g., ordinate scaling). The current study investigated the impact that differences in ordinate scaling, a graphic display characteristic, had on experts' accuracy in judgments regarding the magnitude of effect present in single-case percentage data. 32 participants were asked to evaluate eight ABAB data sets (2 each presenting null, small, moderate, and large effects) along with three iterations of each (32 graphs in total) in which only the ordinate scale was manipulated. Results suggest that raters are less accurate in their detection of treatment effects as the ordinate scale is constricted. Additionally, raters were more likely to overestimate the size of a treatment effect when the ordinate scale was constricted. Copyright © 2017 Society for the Study of School Psychology. Published by Elsevier Ltd. All rights reserved.

  10. The complex network reliability and influential nodes

    Science.gov (United States)

    Li, Kai; He, Yongfeng

    2017-08-01

    In order to study the complex network node important degree and reliability, considering semi-local centrality, betweenness centrality and PageRank algorithm, through the simulation method to gradually remove nodes and recalculate the importance in the random network, small world network and scale-free network. Study the relationship between the largest connected component and node removed proportion, the research results show that betweenness centrality and PageRank algorithm based on the global information network are more effective for evaluating the importance of nodes, and the reliability of the network is related to the network topology.

  11. Nanoscale heterostructures with molecular-scale single-crystal metal wires.

    Science.gov (United States)

    Kundu, Paromita; Halder, Aditi; Viswanath, B; Kundu, Dipan; Ramanath, Ganpati; Ravishankar, N

    2010-01-13

    Creating nanoscale heterostructures with molecular-scale (synthesis of nanoscale heterostructures with single-crystal molecular-scale Au nanowires attached to different nanostructure substrates. Our method involves the formation of Au nanoparticle seeds by the reduction of rocksalt AuCl nanocubes heterogeneously nucleated on the substrates and subsequent nanowire growth by oriented attachment of Au nanoparticles from the solution phase. Nanoscale heterostructures fabricated by such site-specific nucleation and growth are attractive for many applications including nanoelectronic device wiring, catalysis, and sensing.

  12. Modular sensor network node

    Science.gov (United States)

    Davis, Jesse Harper Zehring [Berkeley, CA; Stark, Jr., Douglas Paul; Kershaw, Christopher Patrick [Hayward, CA; Kyker, Ronald Dean [Livermore, CA

    2008-06-10

    A distributed wireless sensor network node is disclosed. The wireless sensor network node includes a plurality of sensor modules coupled to a system bus and configured to sense a parameter. The parameter may be an object, an event or any other parameter. The node collects data representative of the parameter. The node also includes a communication module coupled to the system bus and configured to allow the node to communicate with other nodes. The node also includes a processing module coupled to the system bus and adapted to receive the data from the sensor module and operable to analyze the data. The node also includes a power module connected to the system bus and operable to generate a regulated voltage.

  13. Towards a single empirical correlation to predict kLa across scales and processes

    DEFF Research Database (Denmark)

    Quintanilla Hernandez, Daniela Alejandra; Gernaey, Krist; Albæk, Mads O.

    Mathematical models are increasingly used in fermentation. Nevertheless, one of the major limitations of these models is that the parameters they include are process specific, e.g. the volumetric mass transfer coefficient (kLa). Oxygen transfer was studied in order to establish a single equation...... different calculations of the average shear rate. The experimental kLa value was determined with the direct method; however, eight variations of its calculation were evaluated. Several simple correlations were fitted to the measured kLa data. The standard empirical equation was found to be best...... scales using on ‐ line viscosity measurements. A single correlation for all processes and all scales could not be established...

  14. Related Drupal Nodes Block

    NARCIS (Netherlands)

    Van der Vegt, Wim

    2010-01-01

    Related Drupal Nodes Block This module exposes a block that uses Latent Semantic Analysis (Lsa) internally to suggest three nodes that are relevant to the node a user is viewing. This module performs three tasks. 1) It periodically indexes a Drupal site and generates a Lsa Term Document Matrix.

  15. Live and Dead Nodes

    DEFF Research Database (Denmark)

    Jørgensen, Sune Lehman; Jackson, A. D.

    2005-01-01

    In this paper, we explore the consequences of a distinction between `live' and `dead' network nodes; `live' nodes are able to acquire new links whereas `dead' nodes are static. We develop an analytically soluble growing network model incorporating this distinction and show that it can provide...

  16. Multi-scale simulation of single crystal hollow turbine blade manufactured by liquid metal cooling process

    Directory of Open Access Journals (Sweden)

    Xuewei Yan

    2018-02-01

    Full Text Available Liquid metal cooling (LMC process as a powerful directional solidification (DS technique is prospectively used to manufacture single crystal (SC turbine blades. An understanding of the temperature distribution and microstructure evolution in LMC process is required in order to improve the properties of the blades. For this reason, a multi-scale model coupling with the temperature field, grain growth and solute diffusion was established. The temperature distribution and mushy zone evolution of the hollow blade was simulated and discussed. According to the simulation results, the mushy zone might be convex and ahead of the ceramic beads at a lower withdrawal rate, while it will be concave and laggard at a higher withdrawal rate, and a uniform and horizontal mushy zone will be formed at a medium withdrawal rate. Grain growth of the blade at different withdrawal rates was also investigated. Single crystal structures were all selected out at three different withdrawal rates. Moreover, mis-orientation of the grains at 8 mm/min reached ~30°, while it was ~5° and ~15° at 10 mm/min and 12 mm/min, respectively. The model for predicting dendritic morphology was verified by corresponding experiment. Large scale for 2D dendritic distribution in the whole sections was investigated by experiment and simulation, and they presented a well agreement with each other. Keywords: Hollow blade, Single crystal, Multi-scale simulation, Liquid metal cooling

  17. Soft matter interactions at the molecular scale: interaction forces and energies between single hydrophobic model peptides.

    Science.gov (United States)

    Stock, Philipp; Utzig, Thomas; Valtiner, Markus

    2017-02-08

    In all realms of soft matter research a fundamental understanding of the structure/property relationships based on molecular interactions is crucial for developing a framework for the targeted design of soft materials. However, a molecular picture is often difficult to ascertain and yet essential for understanding the many different competing interactions at play, including entropies and cooperativities, hydration effects, and the enormous design space of soft matter. Here, we characterized for the first time the interaction between single hydrophobic molecules quantitatively using atomic force microscopy, and demonstrated that single molecular hydrophobic interaction free energies are dominated by the area of the smallest interacting hydrophobe. The interaction free energy amounts to 3-4 kT per hydrophobic unit. Also, we find that the transition state of the hydrophobic interactions is located at 3 Å with respect to the ground state, based on Bell-Evans theory. Our results provide a new path for understanding the nature of hydrophobic interactions at the single molecular scale. Our approach enables us to systematically vary hydrophobic and any other interaction type by utilizing peptide chemistry providing a strategic advancement to unravel molecular surface and soft matter interactions at the single molecular scale.

  18. Prognostic significance of classified extramural tumor deposits and extracapsular lymph node invasion in T3–4 colorectal cancer: a retrospective single-center study

    International Nuclear Information System (INIS)

    Yamano, Tomoki; Semba, Shuho; Noda, Masafumi; Yoshimura, Mie; Kobayashi, Masayoshi; Hamanaka, Michiko; Beppu, Naohito; Yano, Aya; Tsukamoto, Kiyoshi; Matsubara, Nagahide; Tomita, Naohiro

    2015-01-01

    Extramural tumor deposits (TDs) and extracapsular lymph node involvement (ECLNI) are considered to be poor prognostic factors in patients with T3–4, N0–2, M0 colorectal cancer (CRC). Although TDs are known to have multiple origins and pleomorphic features, the prognostic significances of the different type of TDs have not yet been established. We performed a retrospective review of 385 consecutive patients with T3–4, N0–2, M0 CRC who received curative resection at our institution between 2006 and 2012. We classified the TDs into two groups: invasive-type TD (iTD), which is characterized by the presence of lymphatic invasion, vascular invasion, perineural invasion, or undefined cancer cell clusters and nodular-type TD (nTD), which is characterized by a smooth or irregular-shaped tumor nodule other than an iTD. ECLNI was defined as invasion of cancer cells into capsular collagen tissues or adipose tissues beyond the capsular collagen. Multivariate analyses were used to assess the prognostic significance of iTD, ND, and ECLNI for relapse-free survival (RFS), disease-specific survival (DSS), and sites of recurrence. In patients without lymph node (LN) metastasis, the incidences of iTD and nTD were both in the range of 2–3 %. Conversely, in patients with LN metastasis, the incidences of iTD, nTD, and ECLNI were 31, 22, and 34 %, respectively. iTD, nTD, and ECLNI were all significant independent adverse factors for RFS in rectal cancer, and were all associated with pT, pN, and LN ratio. iTD was a significant independent adverse prognostic factor for DSS in rectal cancer, metastasis to the liver in colorectal cancer, and distant LN metastasis in colon cancer. ECLNI was a significant independent prognostic factor for RFS in colon cancer. Classifying TDs and assessing ECLNI may help establish significant prognostic factors for patients with T3–4, N0–2, M0 CRC

  19. Role of W and Mn for reliable 1X nanometer-node ultra-large-scale integration Cu interconnects proved by atom probe tomography

    Energy Technology Data Exchange (ETDEWEB)

    Shima, K.; Shimizu, H.; Momose, T.; Shimogaki, Y. [Department of Materials Engineering, The University of Tokyo, 7-3-1, Hongo, Bunkyo-ku, Tokyo 113-8656 (Japan); Tu, Y. [The Oarai Center, Institute for Materials Research, Tohoku University, Oarai, Ibaraki 311-1313 (Japan); Key Laboratory of Polar Materials and Devices, Ministry of Education, East China Normal University, Shanghai 200241 (China); Takamizawa, H.; Shimizu, Y.; Inoue, K.; Nagai, Y. [The Oarai Center, Institute for Materials Research, Tohoku University, Oarai, Ibaraki 311-1313 (Japan)

    2014-09-29

    We used atom probe tomography (APT) to study the use of a Cu(Mn) as a seed layer of Cu, and a Co(W) single-layer as reliable Cu diffusion barriers for future interconnects in ultra-large-scale integration. The use of Co(W) layer enhances adhesion of Cu to prevent electromigration and stress-induced voiding failures. The use of Cu(Mn) as seed layer may enhance the diffusion barrier performance of Co(W) by stuffing the Cu diffusion pass with Mn. APT was used to visualize the distribution of W and Mn in three dimensions with sub-nanometer resolution. W was found to segregate at the grain boundaries of Co, which prevents diffusion of Cu via the grain boundaries. Mn was found to diffuse from the Cu(Mn) layer to Co(W) layer and selectively segregate at the Co(W) grain boundaries with W, reinforcing the barrier properties of Co(W) layer. Hence, a Co(W) barrier coupled with a Cu(Mn) seed layer can form a sufficient diffusion barrier with film that is less than 2.0-nm-thick. The diffusion barrier behavior was preserved following a 1-h annealing at 400 °C. The underlayer of the Cu interconnects requires a large adhesion strength with the Cu, as well as low electrical resistivity. The use of Co(W) has previously been shown to satisfy these requirements, and addition of Mn is not expected to deteriorate these properties.

  20. Large-Scale Mixed Temperate Forest Mapping at the Single Tree Level using Airborne Laser Scanning

    Science.gov (United States)

    Scholl, V.; Morsdorf, F.; Ginzler, C.; Schaepman, M. E.

    2017-12-01

    Monitoring vegetation on a single tree level is critical to understand and model a variety of processes, functions, and changes in forest systems. Remote sensing technologies are increasingly utilized to complement and upscale the field-based measurements of forest inventories. Airborne laser scanning (ALS) systems provide valuable information in the vertical dimension for effective vegetation structure mapping. Although many algorithms exist to extract single tree segments from forest scans, they are often tuned to perform well in homogeneous coniferous or deciduous areas and are not successful in mixed forests. Other methods are too computationally expensive to apply operationally. The aim of this study was to develop a single tree detection workflow using leaf-off ALS data for the canton of Aargau in Switzerland. Aargau covers an area of over 1,400km2 and features mixed forests with various development stages and topography. Forest type was classified using random forests to guide local parameter selection. Canopy height model-based treetop maxima were detected and maintained based on the relationship between tree height and window size, used as a proxy to crown diameter. Watershed segmentation was used to generate crown polygons surrounding each maximum. The location, height, and crown dimensions of single trees were derived from the ALS returns within each polygon. Validation was performed through comparison with field measurements and extrapolated estimates from long-term monitoring plots of the Swiss National Forest Inventory within the framework of the Swiss Federal Institute for Forest, Snow, and Landscape Research. This method shows promise for robust, large-scale single tree detection in mixed forests. The single tree data will aid ecological studies as well as forest management practices. Figure description: Height-normalized ALS point cloud data (top) and resulting single tree segments (bottom) on the Laegeren mountain in Switzerland.

  1. Psychometric properties of the Rosenberg self-esteem scale in African American single mothers.

    Science.gov (United States)

    Hatcher, Jennifer; Hall, Lynne A

    2009-02-01

    The Rosenberg Self-Esteem (RSE) Scale is a commonly used measure of global self-esteem, an important element of mental health. The purpose of this cross sectional secondary analysis was to examine the psychometric properties of the scale in a sample of 98 African American single mothers. The RSE Scale showed adequate internal consistency with an alpha coefficient of .83. Two factors that accounted for a total of 54.7% of the variance were extracted. Self-esteem showed a strong negative relationship with both depressive symptoms and negative thinking. This study provides support for the internal consistency of the RSE Scale and partial support for its construct validity in this population. The RSE appears to represent a bidimensional construct of self-esteem for African American women, with the cultural influences of racial esteem and the rejection of negative stereotypes forming a separate and distinct aspect of this concept. The RSE Scale should be used and interpreted with caution in this population given these findings.

  2. Scaling Analysis of the Single-Phase Natural Circulation: the Hydraulic Similarity

    International Nuclear Information System (INIS)

    Yu, Xin-Guo; Choi, Ki-Yong

    2015-01-01

    These passive safety systems all rely on the natural circulation to cool down the reactor cores during an accident. Thus, a robust and accurate scaling methodology must be developed and employed to both assist in the design of a scaled-down test facility and guide the tests in order to mimic the natural circulation flow of its prototype. The natural circulation system generally consists of a heat source, the connecting pipes and several heat sinks. Although many applauding scaling methodologies have been proposed during last several decades, few works have been dedicated to systematically analyze and exactly preserve the hydraulic similarity. In the present study, the hydraulic similarity analyses are performed at both system and local level. By this mean, the scaling criteria for the exact hydraulic similarity in a full-pressure model have been sought. In other words, not only the system-level but also the local-level hydraulic similarities are pursued. As the hydraulic characteristics of a fluid system is governed by the momentum equation, the scaling analysis starts with it. A dimensionless integral loop momentum equation is derived to obtain the dimensionless numbers. In the dimensionless momentum equation, two dimensionless numbers, the dimensionless flow resistance number and the dimensionless gravitational force number, are identified along with a unique hydraulic time scale, characterizing the system hydraulic response. A full-height full-pressure model is also made to see which model among the full-height model and reduced-height model can preserve the hydraulic behavior of the prototype. From the dimensionless integral momentum equation, a unique hydraulic time scale, which characterizes the hydraulic response of a single-phase natural circulation system, is identified along with two dimensionless parameters: the dimensionless flow resistance number and the dimensionless gravitational force number. By satisfying the equality of both dimensionless numbers

  3. Scaling Analysis of the Single-Phase Natural Circulation: the Hydraulic Similarity

    Energy Technology Data Exchange (ETDEWEB)

    Yu, Xin-Guo; Choi, Ki-Yong [KAERI, Daejeon (Korea, Republic of)

    2015-05-15

    These passive safety systems all rely on the natural circulation to cool down the reactor cores during an accident. Thus, a robust and accurate scaling methodology must be developed and employed to both assist in the design of a scaled-down test facility and guide the tests in order to mimic the natural circulation flow of its prototype. The natural circulation system generally consists of a heat source, the connecting pipes and several heat sinks. Although many applauding scaling methodologies have been proposed during last several decades, few works have been dedicated to systematically analyze and exactly preserve the hydraulic similarity. In the present study, the hydraulic similarity analyses are performed at both system and local level. By this mean, the scaling criteria for the exact hydraulic similarity in a full-pressure model have been sought. In other words, not only the system-level but also the local-level hydraulic similarities are pursued. As the hydraulic characteristics of a fluid system is governed by the momentum equation, the scaling analysis starts with it. A dimensionless integral loop momentum equation is derived to obtain the dimensionless numbers. In the dimensionless momentum equation, two dimensionless numbers, the dimensionless flow resistance number and the dimensionless gravitational force number, are identified along with a unique hydraulic time scale, characterizing the system hydraulic response. A full-height full-pressure model is also made to see which model among the full-height model and reduced-height model can preserve the hydraulic behavior of the prototype. From the dimensionless integral momentum equation, a unique hydraulic time scale, which characterizes the hydraulic response of a single-phase natural circulation system, is identified along with two dimensionless parameters: the dimensionless flow resistance number and the dimensionless gravitational force number. By satisfying the equality of both dimensionless numbers

  4. Single or multiple synchronization transitions in scale-free neuronal networks with electrical or chemical coupling

    International Nuclear Information System (INIS)

    Hao Yinghang; Gong, Yubing; Wang Li; Ma Xiaoguang; Yang Chuanlu

    2011-01-01

    Research highlights: → Single synchronization transition for gap-junctional coupling. → Multiple synchronization transitions for chemical synaptic coupling. → Gap junctions and chemical synapses have different impacts on synchronization transition. → Chemical synapses may play a dominant role in neurons' information processing. - Abstract: In this paper, we have studied time delay- and coupling strength-induced synchronization transitions in scale-free modified Hodgkin-Huxley (MHH) neuron networks with gap-junctions and chemical synaptic coupling. It is shown that the synchronization transitions are much different for these two coupling types. For gap-junctions, the neurons exhibit a single synchronization transition with time delay and coupling strength, while for chemical synapses, there are multiple synchronization transitions with time delay, and the synchronization transition with coupling strength is dependent on the time delay lengths. For short delays we observe a single synchronization transition, whereas for long delays the neurons exhibit multiple synchronization transitions as the coupling strength is varied. These results show that gap junctions and chemical synapses have different impacts on the pattern formation and synchronization transitions of the scale-free MHH neuronal networks, and chemical synapses, compared to gap junctions, may play a dominant and more active function in the firing activity of the networks. These findings would be helpful for further understanding the roles of gap junctions and chemical synapses in the firing dynamics of neuronal networks.

  5. Single or multiple synchronization transitions in scale-free neuronal networks with electrical or chemical coupling

    Energy Technology Data Exchange (ETDEWEB)

    Hao Yinghang [School of Physics, Ludong University, Yantai 264025 (China); Gong, Yubing, E-mail: gongyubing09@hotmail.co [School of Physics, Ludong University, Yantai 264025 (China); Wang Li; Ma Xiaoguang; Yang Chuanlu [School of Physics, Ludong University, Yantai 264025 (China)

    2011-04-15

    Research highlights: Single synchronization transition for gap-junctional coupling. Multiple synchronization transitions for chemical synaptic coupling. Gap junctions and chemical synapses have different impacts on synchronization transition. Chemical synapses may play a dominant role in neurons' information processing. - Abstract: In this paper, we have studied time delay- and coupling strength-induced synchronization transitions in scale-free modified Hodgkin-Huxley (MHH) neuron networks with gap-junctions and chemical synaptic coupling. It is shown that the synchronization transitions are much different for these two coupling types. For gap-junctions, the neurons exhibit a single synchronization transition with time delay and coupling strength, while for chemical synapses, there are multiple synchronization transitions with time delay, and the synchronization transition with coupling strength is dependent on the time delay lengths. For short delays we observe a single synchronization transition, whereas for long delays the neurons exhibit multiple synchronization transitions as the coupling strength is varied. These results show that gap junctions and chemical synapses have different impacts on the pattern formation and synchronization transitions of the scale-free MHH neuronal networks, and chemical synapses, compared to gap junctions, may play a dominant and more active function in the firing activity of the networks. These findings would be helpful for further understanding the roles of gap junctions and chemical synapses in the firing dynamics of neuronal networks.

  6. Design of an omnidirectional single-point photodetector for large-scale spatial coordinate measurement

    Science.gov (United States)

    Xie, Hongbo; Mao, Chensheng; Ren, Yongjie; Zhu, Jigui; Wang, Chao; Yang, Lei

    2017-10-01

    In high precision and large-scale coordinate measurement, one commonly used approach to determine the coordinate of a target point is utilizing the spatial trigonometric relationships between multiple laser transmitter stations and the target point. A light receiving device at the target point is the key element in large-scale coordinate measurement systems. To ensure high-resolution and highly sensitive spatial coordinate measurement, a high-performance and miniaturized omnidirectional single-point photodetector (OSPD) is greatly desired. We report one design of OSPD using an aspheric lens, which achieves an enhanced reception angle of -5 deg to 45 deg in vertical and 360 deg in horizontal. As the heart of our OSPD, the aspheric lens is designed in a geometric model and optimized by LightTools Software, which enables the reflection of a wide-angle incident light beam into the single-point photodiode. The performance of home-made OSPD is characterized with working distances from 1 to 13 m and further analyzed utilizing developed a geometric model. The experimental and analytic results verify that our device is highly suitable for large-scale coordinate metrology. The developed device also holds great potential in various applications such as omnidirectional vision sensor, indoor global positioning system, and optical wireless communication systems.

  7. Protocol for multiple node network

    Science.gov (United States)

    Kirkham, Harold (Inventor)

    1995-01-01

    The invention is a multiple interconnected network of intelligent message-repeating remote nodes which employs an antibody recognition message termination process performed by all remote nodes and a remote node polling process performed by other nodes which are master units controlling remote nodes in respective zones of the network assigned to respective master nodes. Each remote node repeats only those messages originated in the local zone, to provide isolation among the master nodes.

  8. Beginning Amazon Web Services with Node.js

    CERN Document Server

    Shackelford, Adam

    2015-01-01

    Beginning Amazon Web Services with Node.js teaches any novice Node.js developer to configure, deploy, and maintain scalable small to large scale Node.js applications in Amazon Web Services. Hosting a Node.js application in a production environment usually means turning to PaaS hosting, but this approach brings problems. Deploying Node.js directly to AWS solves the problems you encounter in these situations, enabling you to cut out the middle man. You will begin with a basic RESTful web service in Node.js, using the popular Express.js framework, pre-built and ready to run in your local env

  9. Large-Scale Synthesis of Single-Crystalline Iron Oxide Magnetic Nanorings

    DEFF Research Database (Denmark)

    Jia, Chun-Jiang; Sun, Ling-Dong; Luo, Feng

    2008-01-01

    We present an innovative approach to the production of single-crystal iron oxide nanorings employing a solution-based route. Single-crystal hematite (alpha-Fe2O3) nanorings were synthesized using a double anion-assisted hydrothermal method (involving phosphate and sulfate ions), which can...... an intriguing three-dimensional magnetic configuration. This work provides an easily scaled-up method for preparing tailor-made iron oxide nanorings that could meet the demands of a variety of applications ranging from medicine to magnetoelectronics....... able to control the size, morphology, and surface architecture to produce a variety of three-dimensional hollow nanostructures. These can then be converted to magnetite (Fe3O4) and maghemite (gamma-Fe2O3) by a reduction or reduction-oxidation process while preserving the same morphology. The structures...

  10. An adjustable multi-scale single beam acoustic tweezers based on ultrahigh frequency ultrasonic transducer.

    Science.gov (United States)

    Chen, Xiaoyang; Lam, Kwok Ho; Chen, Ruimin; Chen, Zeyu; Yu, Ping; Chen, Zhongping; Shung, K Kirk; Zhou, Qifa

    2017-11-01

    This paper reports the fabrication, characterization, and microparticle manipulation capability of an adjustable multi-scale single beam acoustic tweezers (SBAT) that is capable of flexibly changing the size of "tweezers" like ordinary metal tweezers with a single-element ultrahigh frequency (UHF) ultrasonic transducer. The measured resonant frequency of the developed transducer at 526 MHz is the highest frequency of piezoelectric single crystal based ultrasonic transducers ever reported. This focused UHF ultrasonic transducer exhibits a wide bandwidth (95.5% at -10 dB) due to high attenuation of high-frequency ultrasound wave, which allows the SBAT effectively excite with a wide range of excitation frequency from 150 to 400 MHz by using the "piezoelectric actuator" model. Through controlling the excitation frequency, the wavelength of ultrasound emitted from the SBAT can be changed to selectively manipulate a single microparticle of different sizes (3-100 μm) by using only one transducer. This concept of flexibly changing "tweezers" size is firstly introduced into the study of SBAT. At the same time, it was found that this incident ultrasound wavelength play an important role in lateral trapping and manipulation for microparticle of different sizes. Biotechnol. Bioeng. 2017;114: 2637-2647. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  11. The Node Monitoring Component of a Scalable Systems Software Environment

    Energy Technology Data Exchange (ETDEWEB)

    Miller, Samuel James [Iowa State Univ., Ames, IA (United States)

    2006-01-01

    This research describes Fountain, a suite of programs used to monitor the resources of a cluster. A cluster is a collection of individual computers that are connected via a high speed communication network. They are traditionally used by users who desire more resources, such as processing power and memory, than any single computer can provide. A common drawback to effectively utilizing such a large-scale system is the management infrastructure, which often does not often scale well as the system grows. Large-scale parallel systems provide new research challenges in the area of systems software, the programs or tools that manage the system from boot-up to running a parallel job. The approach presented in this thesis utilizes a collection of separate components that communicate with each other to achieve a common goal. While systems software comprises a broad array of components, this thesis focuses on the design choices for a node monitoring component. We will describe Fountain, an implementation of the Scalable Systems Software (SSS) node monitor specification. It is targeted at aggregate node monitoring for clusters, focusing on both scalability and fault tolerance as its design goals. It leverages widely used technologies such as XML and HTTP to present an interface to other components in the SSS environment.

  12. Atomic scale mass delivery driven by bend kink in single walled carbon nanotube

    International Nuclear Information System (INIS)

    Kan Biao; Ding Jianning; Ling Zhiyong; Yuan Ningyi; Cheng Guanggui

    2010-01-01

    The possibility of atomic scale mass delivery by bend kink in single walled carbon nanotube was investigated with the aid of molecular dynamics simulation. By keeping the bending angle while moving the tube end, the encapsulated atomic scale mass such as atom, molecule and atom group were successfully delivered through the nanotube. The van der Waals interaction between the encapsulated mass and the tube wall provided the driving force for the delivery. There were no dramatic changes in the van der Waals interaction, and a smooth and steady delivery was achieved when constant loading rate was applied. The influence of temperature on the atom group delivery was also analyzed. It is found raising temperature is harmful to the smooth movement of the atom group. However, the delivery rate can be promoted under higher temperature when the atom group is situated before the kink during the delivery.

  13. Control Algorithms for Large-scale Single-axis Photovoltaic Trackers

    Directory of Open Access Journals (Sweden)

    Dorian Schneider

    2012-01-01

    Full Text Available The electrical yield of large-scale photovoltaic power plants can be greatly improved by employing solar trackers. While fixed-tilt superstructures are stationary and immobile, trackers move the PV-module plane in order to optimize its alignment to the sun. This paper introduces control algorithms for single-axis trackers (SAT, including a discussion for optimal alignment and backtracking. The results are used to simulate and compare the electrical yield of fixed-tilt and SAT systems. The proposed algorithms have been field tested, and are in operation in solar parks worldwide.

  14. The method of arbitrarily large moments to calculate single scale processes in quantum field theory

    Energy Technology Data Exchange (ETDEWEB)

    Bluemlein, Johannes [Deutsches Elektronen-Synchrotron (DESY), Zeuthen (Germany); Schneider, Carsten [Johannes Kepler Univ., Linz (Austria). Research Inst. for Symbolic Computation (RISC)

    2017-01-15

    We device a new method to calculate a large number of Mellin moments of single scale quantities using the systems of differential and/or difference equations obtained by integration-by-parts identities between the corresponding Feynman integrals of loop corrections to physical quantities. These scalar quantities have a much simpler mathematical structure than the complete quantity. A sufficiently large set of moments may even allow the analytic reconstruction of the whole quantity considered, holding in case of first order factorizing systems. In any case, one may derive highly precise numerical representations in general using this method, which is otherwise completely analytic.

  15. The method of arbitrarily large moments to calculate single scale processes in quantum field theory

    Directory of Open Access Journals (Sweden)

    Johannes Blümlein

    2017-08-01

    Full Text Available We devise a new method to calculate a large number of Mellin moments of single scale quantities using the systems of differential and/or difference equations obtained by integration-by-parts identities between the corresponding Feynman integrals of loop corrections to physical quantities. These scalar quantities have a much simpler mathematical structure than the complete quantity. A sufficiently large set of moments may even allow the analytic reconstruction of the whole quantity considered, holding in case of first order factorizing systems. In any case, one may derive highly precise numerical representations in general using this method, which is otherwise completely analytic.

  16. Statistical analysis of error rate of large-scale single flux quantum logic circuit by considering fluctuation of timing parameters

    International Nuclear Information System (INIS)

    Yamanashi, Yuki; Masubuchi, Kota; Yoshikawa, Nobuyuki

    2016-01-01

    The relationship between the timing margin and the error rate of the large-scale single flux quantum logic circuits is quantitatively investigated to establish a timing design guideline. We observed that the fluctuation in the set-up/hold time of single flux quantum logic gates caused by thermal noises is the most probable origin of the logical error of the large-scale single flux quantum circuit. The appropriate timing margin for stable operation of the large-scale logic circuit is discussed by taking the fluctuation of setup/hold time and the timing jitter in the single flux quantum circuits. As a case study, the dependence of the error rate of the 1-million-bit single flux quantum shift register on the timing margin is statistically analyzed. The result indicates that adjustment of timing margin and the bias voltage is important for stable operation of a large-scale SFQ logic circuit.

  17. Statistical analysis of error rate of large-scale single flux quantum logic circuit by considering fluctuation of timing parameters

    Energy Technology Data Exchange (ETDEWEB)

    Yamanashi, Yuki, E-mail: yamanasi@ynu.ac.jp [Department of Electrical and Computer Engineering, Yokohama National University, Tokiwadai 79-5, Hodogaya-ku, Yokohama 240-8501 (Japan); Masubuchi, Kota; Yoshikawa, Nobuyuki [Department of Electrical and Computer Engineering, Yokohama National University, Tokiwadai 79-5, Hodogaya-ku, Yokohama 240-8501 (Japan)

    2016-11-15

    The relationship between the timing margin and the error rate of the large-scale single flux quantum logic circuits is quantitatively investigated to establish a timing design guideline. We observed that the fluctuation in the set-up/hold time of single flux quantum logic gates caused by thermal noises is the most probable origin of the logical error of the large-scale single flux quantum circuit. The appropriate timing margin for stable operation of the large-scale logic circuit is discussed by taking the fluctuation of setup/hold time and the timing jitter in the single flux quantum circuits. As a case study, the dependence of the error rate of the 1-million-bit single flux quantum shift register on the timing margin is statistically analyzed. The result indicates that adjustment of timing margin and the bias voltage is important for stable operation of a large-scale SFQ logic circuit.

  18. High-pT Jet Energy Scale Uncertainty from single hadron response with the ATLAS detector

    CERN Document Server

    AUTHOR|(INSPIRE)INSPIRE-00534683; The ATLAS collaboration

    2016-01-01

    The jet energy scale (JES) uncertainty is estimated using different methods at different p$_\\text{T}$ ranges. In-situ techniques exploiting the p$_\\text{T}$ balance between a jet and a reference object (e.g. Z or gamma) are used at lower p$_\\text{T}$, but at very high p$_\\text{T}$ (> 2.5 TeV) there is not enough statistics for such in-situ techniques. A low JES uncertainty at high-p$_\\text{T}$ is important in several searches for new phenomena, e.g. the dijet resonance and angular searches. In the highest p$_\\text{T}$ range, the JES uncertainty is estimated using the calorimeter response to single hadrons. In this method, jets are treated as a superposition of energy depositions of single particles. An uncertainty is applied to each energy deposition belonging to the particles within the jet, and propagated to the final jet energy scale. This poster presents the JES uncertainty found with this method at sqrt(s) = 8 TeV and its developments.

  19. Large curvature and background scale independence in single-metric approximations to asymptotic safety

    Energy Technology Data Exchange (ETDEWEB)

    Morris, Tim R. [STAG Research Centre & Department of Physics and Astronomy, University of Southampton,Highfield, Southampton, SO17 1BJ (United Kingdom)

    2016-11-25

    In single-metric approximations to the exact renormalization group (RG) for quantum gravity, it has been not been clear how to treat the large curvature domain beyond the point where the effective cutoff scale k is less than the lowest eigenvalue of the appropriate modified Laplacian. We explain why this puzzle arises from background dependence, resulting in Wilsonian RG concepts being inapplicable. We show that when properly formulated over an ensemble of backgrounds, the Wilsonian RG can be restored. This in turn implies that solutions should be smooth and well defined no matter how large the curvature is taken. Even for the standard single-metric type approximation schemes, this construction can be rigorously derived by imposing a modified Ward identity (mWI) corresponding to rescaling the background metric by a constant factor. However compatibility in this approximation requires the space-time dimension to be six. Solving the mWI and flow equation simultaneously, new variables are then derived that are independent of overall background scale.

  20. Rating the methodological quality of single-subject designs and n-of-1 trials: introducing the Single-Case Experimental Design (SCED) Scale.

    Science.gov (United States)

    Tate, Robyn L; McDonald, Skye; Perdices, Michael; Togher, Leanne; Schultz, Regina; Savage, Sharon

    2008-08-01

    Rating scales that assess methodological quality of clinical trials provide a means to critically appraise the literature. Scales are currently available to rate randomised and non-randomised controlled trials, but there are none that assess single-subject designs. The Single-Case Experimental Design (SCED) Scale was developed for this purpose and evaluated for reliability. Six clinical researchers who were trained and experienced in rating methodological quality of clinical trials developed the scale and participated in reliability studies. The SCED Scale is an 11-item rating scale for single-subject designs, of which 10 items are used to assess methodological quality and use of statistical analysis. The scale was developed and refined over a 3-year period. Content validity was addressed by identifying items to reduce the main sources of bias in single-case methodology as stipulated by authorities in the field, which were empirically tested against 85 published reports. Inter-rater reliability was assessed using a random sample of 20/312 single-subject reports archived in the Psychological Database of Brain Impairment Treatment Efficacy (PsycBITE). Inter-rater reliability for the total score was excellent, both for individual raters (overall ICC = 0.84; 95% confidence interval 0.73-0.92) and for consensus ratings between pairs of raters (overall ICC = 0.88; 95% confidence interval 0.78-0.95). Item reliability was fair to excellent for consensus ratings between pairs of raters (range k = 0.48 to 1.00). The results were replicated with two independent novice raters who were trained in the use of the scale (ICC = 0.88, 95% confidence interval 0.73-0.95). The SCED Scale thus provides a brief and valid evaluation of methodological quality of single-subject designs, with the total score demonstrating excellent inter-rater reliability using both individual and consensus ratings. Items from the scale can also be used as a checklist in the design, reporting and critical

  1. Development of fine-resolution analyses and expanded large-scale forcing properties: 2. Scale awareness and application to single-column model experiments

    Science.gov (United States)

    Feng, Sha; Li, Zhijin; Liu, Yangang; Lin, Wuyin; Zhang, Minghua; Toto, Tami; Vogelmann, Andrew M.; Endo, Satoshi

    2015-01-01

    three-dimensional fields have been produced using the Community Gridpoint Statistical Interpolation (GSI) data assimilation system for the U.S. Department of Energy's Atmospheric Radiation Measurement Program (ARM) Southern Great Plains region. The GSI system is implemented in a multiscale data assimilation framework using the Weather Research and Forecasting model at a cloud-resolving resolution of 2 km. From the fine-resolution three-dimensional fields, large-scale forcing is derived explicitly at grid-scale resolution; a subgrid-scale dynamic component is derived separately, representing subgrid-scale horizontal dynamic processes. Analyses show that the subgrid-scale dynamic component is often a major component over the large-scale forcing for grid scales larger than 200 km. The single-column model (SCM) of the Community Atmospheric Model version 5 is used to examine the impact of the grid-scale and subgrid-scale dynamic components on simulated precipitation and cloud fields associated with a mesoscale convective system. It is found that grid-scale size impacts simulated precipitation, resulting in an overestimation for grid scales of about 200 km but an underestimation for smaller grids. The subgrid-scale dynamic component has an appreciable impact on the simulations, suggesting that grid-scale and subgrid-scale dynamic components should be considered in the interpretation of SCM simulations.

  2. Comparison of Single and Multi-Scale Method for Leaf and Wood Points Classification from Terrestrial Laser Scanning Data

    Science.gov (United States)

    Wei, Hongqiang; Zhou, Guiyun; Zhou, Junjie

    2018-04-01

    The classification of leaf and wood points is an essential preprocessing step for extracting inventory measurements and canopy characterization of trees from the terrestrial laser scanning (TLS) data. The geometry-based approach is one of the widely used classification method. In the geometry-based method, it is common practice to extract salient features at one single scale before the features are used for classification. It remains unclear how different scale(s) used affect the classification accuracy and efficiency. To assess the scale effect on the classification accuracy and efficiency, we extracted the single-scale and multi-scale salient features from the point clouds of two oak trees of different sizes and conducted the classification on leaf and wood. Our experimental results show that the balanced accuracy of the multi-scale method is higher than the average balanced accuracy of the single-scale method by about 10 % for both trees. The average speed-up ratio of single scale classifiers over multi-scale classifier for each tree is higher than 30.

  3. Psychometric properties of a single-item scale to assess sleep quality among individuals with fibromyalgia

    Directory of Open Access Journals (Sweden)

    Sadosky Alesia B

    2009-06-01

    Full Text Available Abstract Background Sleep disturbances are a common and bothersome symptom of fibromyalgia (FM. This study reports psychometric properties of a single-item scale to assess sleep quality among individuals with FM. Methods Analyses were based on data from two randomized, double-blind, placebo-controlled trials of pregabalin (studies 1056 and 1077. In a daily diary, patients reported the quality of their sleep on a numeric rating scale ranging from 0 ("best possible sleep" to 10 ("worst possible sleep". Test re-test reliability of the Sleep Quality Scale was evaluated by computing intraclass correlation coefficients. Pearson correlation coefficients were computed between baseline Sleep Quality scores and baseline pain diary and Medical Outcomes Study (MOS Sleep scores. Responsiveness to treatment was evaluated by standardized effect sizes computed as the difference between least squares mean changes in Sleep Quality scores in the pregabalin and placebo groups divided by the standard deviation of Sleep Quality scores across all patients at baseline. Results Studies 1056 and 1077 included 748 and 745 patients, respectively. Most patients were female (study 1056: 94.4%; study 1077: 94.5% and white (study 1056: 90.2%; study 1077: 91.0%. Mean ages were 48.8 years (study 1056 and 50.1 years (study 1077. Test re-test reliability coefficients of the Sleep Quality Scale were 0.91 and 0.90 in the 1056 and 1077 studies, respectively. Pearson correlation coefficients between baseline Sleep Quality scores and baseline pain diary scores were 0.64 (p Conclusion These results provide evidence of the reproducibility, convergent validity, and responsiveness to treatment of the Sleep Quality Scale and provide a foundation for its further use and evaluation in FM patients.

  4. Current scaling of radiated power for 40-mm diameter single wire arrays on Z

    Science.gov (United States)

    Nash, T. J.; Cuneo, M. E.; Spielman, R. B.; Chandler, G. A.; Leeper, R. J.; Seaman, J. F.; McGurn, J.; Lazier, S.; Torres, J.; Jobe, D.; Gilliland, T.; Nielsen, D.; Hawn, R.; Bailey, J. E.; Lake, P.; Carlson, A. L.; Seamen, H.; Moore, T.; Smelser, R.; Pyle, J.; Wagoner, T. C.; LePell, P. D.; Deeney, C.; Douglas, M. R.; McDaniel, D.; Struve, K.; Mazarakis, M.; Stygar, W. A.

    2004-11-01

    In order to estimate the radiated power that can be expected from the next-generation Z-pinch driver such as ZR at 28 MA, current-scaling experiments have been conducted on the 20 MA driver Z. We report on the current scaling of single 40 mm diameter tungsten 240 wire arrays with a fixed 110 ns implosion time. The wire diameter is decreased in proportion to the load current. Reducing the charge voltage on the Marx banks reduces the load current. On one shot, firing only three of the four levels of the Z machine further reduced the load current. The radiated energy scaled as the current squared as expected but the radiated power scaled as the current to the 3.52±0.42 power due to increased x-ray pulse width at lower current. As the current is reduced, the rise time of the x-ray pulse increases and at the lowest current value of 10.4 MA, a shoulder appears on the leading edge of the x-ray pulse. In order to determine the nature of the plasma producing the leading edge of the x-ray pulse at low currents further shots were taken with an on-axis aperture to view on-axis precursor plasma. This aperture appeared to perturb the pinch in a favorable manner such that with the aperture in place there was no leading edge to the x-ray pulses at lower currents and the radiated power scaled as the current squared ±0.75. For a full-current shot we will present x-ray images that show precursor plasma emitting on-axis 77 ns before the main x-ray burst.

  5. Single-polymer dynamics under constraints: scaling theory and computer experiment

    International Nuclear Information System (INIS)

    Milchev, Andrey

    2011-01-01

    The relaxation, diffusion and translocation dynamics of single linear polymer chains in confinement is briefly reviewed with emphasis on the comparison between theoretical scaling predictions and observations from experiment or, most frequently, from computer simulations. Besides cylindrical, spherical and slit-like constraints, related problems such as the chain dynamics in a random medium and the translocation dynamics through a nanopore are also considered. Another particular kind of confinement is imposed by polymer adsorption on attractive surfaces or selective interfaces-a short overview of single-chain dynamics is also contained in this survey. While both theory and numerical experiments consider predominantly coarse-grained models of self-avoiding linear chain molecules with typically Rouse dynamics, we also note some recent studies which examine the impact of hydrodynamic interactions on polymer dynamics in confinement. In all of the aforementioned cases we focus mainly on the consequences of imposed geometric restrictions on single-chain dynamics and try to check our degree of understanding by assessing the agreement between theoretical predictions and observations. (topical review)

  6. Transition from many domain to single domain martensite morphology in small-scale shape memory alloys

    International Nuclear Information System (INIS)

    Ueland, Stian M.; Schuh, Christopher A.

    2013-01-01

    The morphology of the martensitic transformation during a superelastic cycle is studied by in situ scanning electron microscopy deformation experiments in microwires of Cu–Zn–Al. The diameters of the wires studied (21–136 μm) span the range in which significant size effects upon transformation hysteresis have been observed. In larger wires the transformation is accommodated by the continual nucleation of many new martensite plates that grow and eventually coalesce with their neighbors. In small wires a single martensite plate nucleates at the start of transformation and then proceeds to grow in a monolithic fashion; the wire transforms by smooth axial propagation of a single interface. The transition from many domain to single domain transformation is gradual with wire diameter, and is based upon scaling of the domain density with sample size. We attribute it to a crossover from bulk to surface obstacle control of transformation front propagation. This observation also sheds light on reported size effects in energy dissipation in shape memory alloys

  7. Multi-scale Modeling of Compressible Single-phase Flow in Porous Media using Molecular Simulation

    KAUST Repository

    Saad, Ahmed Mohamed

    2016-05-01

    In this study, an efficient coupling between Monte Carlo (MC) molecular simulation and Darcy-scale flow in porous media is presented. The cell-centered finite difference method with a non-uniform rectangular mesh were used to discretize the simulation domain and solve the governing equations. To speed up the MC simulations, we implemented a recently developed scheme that quickly generates MC Markov chains out of pre-computed ones, based on the reweighting and reconstruction algorithm. This method astonishingly reduces the required computational time by MC simulations from hours to seconds. In addition, the reweighting and reconstruction scheme, which was originally designed to work with the LJ potential model, is extended to work with a potential model that accounts for the molecular quadrupole moment of fluids with non-spherical molecules such as CO2. The potential model was used to simulate the thermodynamic equilibrium properties for single-phase and two-phase systems using the canonical ensemble and the Gibbs ensemble, respectively. Comparing the simulation results with the experimental data showed that the implemented model has an excellent fit outperforming the standard LJ model. To demonstrate the strength of the proposed coupling in terms of computational time efficiency and numerical accuracy in fluid properties, various numerical experiments covering different compressible single-phase flow scenarios were conducted. The novelty in the introduced scheme is in allowing an efficient coupling of the molecular scale and Darcy scale in reservoir simulators. This leads to an accurate description of the thermodynamic behavior of the simulated reservoir fluids; consequently enhancing the confidence in the flow predictions in porous media.

  8. Determinants of single family residential water use across scales in four western US cities.

    Science.gov (United States)

    Chang, Heejun; Bonnette, Matthew Ryan; Stoker, Philip; Crow-Miller, Britt; Wentz, Elizabeth

    2017-10-15

    A growing body of literature examines urban water sustainability with increasing evidence that locally-based physical and social spatial interactions contribute to water use. These studies however are based on single-city analysis and often fail to consider whether these interactions occur more generally. We examine a multi-city comparison using a common set of spatially-explicit water, socioeconomic, and biophysical data. We investigate the relative importance of variables for explaining the variations of single family residential (SFR) water uses at Census Block Group (CBG) and Census Tract (CT) scales in four representative western US cities - Austin, Phoenix, Portland, and Salt Lake City, - which cover a wide range of climate and development density. We used both ordinary least squares regression and spatial error regression models to identify the influence of spatial dependence on water use patterns. Our results show that older downtown areas show lower water use than newer suburban areas in all four cities. Tax assessed value and building age are the main determinants of SFR water use across the four cities regardless of the scale. Impervious surface area becomes an important variable for summer water use in all cities, and it is important in all seasons for arid environments such as Phoenix. CT level analysis shows better model predictability than CBG analysis. In all cities, seasons, and spatial scales, spatial error regression models better explain the variations of SFR water use. Such a spatially-varying relationship of urban water consumption provides additional evidence for the need to integrate urban land use planning and municipal water planning. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Deploying Node.js

    CERN Document Server

    Pasquali, Sandro

    2015-01-01

    If you are an intermediate or advanced developer deploying your Node.js applications, then this book is for you. If you have already built a Node application or module and want to take your knowledge to the next level, this book will help you find your way.

  10. Efficient Graph Computation for Node2Vec

    OpenAIRE

    Zhou, Dongyan; Niu, Songjie; Chen, Shimin

    2018-01-01

    Node2Vec is a state-of-the-art general-purpose feature learning method for network analysis. However, current solutions cannot run Node2Vec on large-scale graphs with billions of vertices and edges, which are common in real-world applications. The existing distributed Node2Vec on Spark incurs significant space and time overhead. It runs out of memory even for mid-sized graphs with millions of vertices. Moreover, it considers at most 30 edges for every vertex in generating random walks, causin...

  11. NRC/UBC Node

    Energy Technology Data Exchange (ETDEWEB)

    Ellis-Perry, B. [Univ. of British Columbia, Vancouver, British Columbia (Canada); Yogendran, Y. [NRC Inst. for Fuel Cell Innovation, Vancouver, British Columbia (Canada)

    2004-07-01

    reality. Demonstration projects will include a hydrogen fuelling station, solid oxide fuel cells, hydrogen powered internal combustion engine shuttle buses, and on-campus hydrogen fuel cell vehicles. The project will be promoted through an integrated communications program, building awareness and support among investors and the public, and so accelerating the early adoption of this technology on a broader scale. Yoga Yogandren and Barney Ellis-Perry will review the UBC/NRC Node, discussing the power of partnerships that are enabling this project to move from an idea to reality. (author)

  12. NRC/UBC Node

    International Nuclear Information System (INIS)

    Ellis-Perry, B.; Yogendran, Y.

    2004-01-01

    . Demonstration projects will include a hydrogen fuelling station, solid oxide fuel cells, hydrogen powered internal combustion engine shuttle buses, and on-campus hydrogen fuel cell vehicles. The project will be promoted through an integrated communications program, building awareness and support among investors and the public, and so accelerating the early adoption of this technology on a broader scale. Yoga Yogandren and Barney Ellis-Perry will review the UBC/NRC Node, discussing the power of partnerships that are enabling this project to move from an idea to reality. (author)

  13. Max-Min SINR in Large-Scale Single-Cell MU-MIMO: Asymptotic Analysis and Low Complexity Transceivers

    KAUST Repository

    Sifaou, Houssem; Kammoun, Abla; Sanguinetti, Luca; Debbah, Merouane; Alouini, Mohamed-Slim

    2016-01-01

    This work focuses on the downlink and uplink of large-scale single-cell MU-MIMO systems in which the base station (BS) endowed with M antennas communicates with K single-antenna user equipments (UEs). Particularly, we aim at reducing the complexity

  14. Single nucleotide polymorphism rs13042395 in the SLC52A3 gene as a biomarker for regional lymph node metastasis and relapse-free survival of esophageal squamous cell carcinoma patients

    International Nuclear Information System (INIS)

    Tan, Hua-Zhen; Wu, Zhi-Yong; Wu, Jian-Yi; Long, Lin; Jiao, Ji-Wei; Peng, Yu-Hui; Xu, Yi-Wei; Li, Shan-Shan; Wang, Wei; Zhang, Jian-Jun; Li, En-Min; Xu, Li-Yan

    2016-01-01

    SLC52A3 was recently identified as a susceptibility gene for esophageal squamous cell carcinoma (ESCC). However, associations between the single nucleotide polymorphisms (SNPs) rs13042395 (C > T) and rs3746803 (G > A) in SLC52A3 and risk, tumor characteristics and survival of ESCC patients remain inconclusive and of unknown prognostic significance. Analyses of the association between SNPs in SLC52A3 and ESCC risk were performed on 479 ESCC cases, together with 479 controls, in a case-control study. Blood samples for cases and controls were collected and genotyped by real-time polymerase chain reaction (PCR) using TaqMan assays. Among the 479 ESCC cases, 343 cases with complete clinical data were used to investigate the association between SNPs and ESCC clinical characteristics; 288 cases with complete clinical data and 5-year follow-up data were used to analyze the association between SNPs and prognosis. Dual luciferase reporter assays and electrophoretic mobility shift assays (EMSAs) were used to investigate the biological function of rs13042395. No association was found between SLC52A3 rs3746803 and susceptibility, tumor characteristics or survival of ESCC patients. For rs13042395, TT genotype carriers were likely to have reduced lymph node metastasis (odds ratio (OR) = 0.55, 95 % confidence interval (CI), 0.31–0.98) and longer relapse-free survival time (P = 0.03) . Also, both rs13042395 (hazard ratio (HR) = 0.62, 95 % CI, 0.38–0.99) and regional lymph node metastasis (HR = 2.06, 95 % CI, 1.36–3.13 for N1 vs. N0; HR = 2.88, 95 % CI, 1.70–4.86 for N2 vs. N0; HR = 2.08, 95 % CI, 1.01–4.30 for N3 vs. N0) were independent factors affecting relapse-free survival for ESCC patients who underwent surgery. Dual luciferase reporter assays and EMSAs suggested that the CC genotype of rs13042395 enhanced SLC52A3 expression, probably via binding with specific transcription factors. The rs13042395 polymorphism in SLC52A3 is associated with regional lymph node

  15. Development and validation of the Single Item Trait Empathy Scale (SITES).

    Science.gov (United States)

    Konrath, Sara; Meier, Brian P; Bushman, Brad J

    2018-04-01

    Empathy involves feeling compassion for others and imagining how they feel. In this article, we develop and validate the Single Item Trait Empathy Scale (SITES), which contains only one item that takes seconds to complete. In seven studies (N=5,724), the SITES was found to be both reliable and valid. It correlated in expected ways with a wide variety of intrapersonal outcomes. For example, it is negatively correlated with narcissism, depression, anxiety, and alexithymia. In contrast, it is positively correlated with other measures of empathy, self-esteem, subjective well-being, and agreeableness. The SITES also correlates with a wide variety of interpersonal outcomes, especially compassion for others and helping others. The SITES is recommended in situations when time or question quantity is constrained.

  16. Burnout of pulverized biomass particles in large scale boiler - Single particle model approach

    Energy Technology Data Exchange (ETDEWEB)

    Saastamoinen, Jaakko; Aho, Martti; Moilanen, Antero [VTT Technical Research Centre of Finland, Box 1603, 40101 Jyvaeskylae (Finland); Soerensen, Lasse Holst [ReaTech/ReAddit, Frederiksborgsveij 399, Niels Bohr, DK-4000 Roskilde (Denmark); Clausen, Soennik [Risoe National Laboratory, DK-4000 Roskilde (Denmark); Berg, Mogens [ENERGI E2 A/S, A.C. Meyers Vaenge 9, DK-2450 Copenhagen SV (Denmark)

    2010-05-15

    Burning of coal and biomass particles are studied and compared by measurements in an entrained flow reactor and by modelling. The results are applied to study the burning of pulverized biomass in a large scale utility boiler originally planned for coal. A simplified single particle approach, where the particle combustion model is coupled with one-dimensional equation of motion of the particle, is applied for the calculation of the burnout in the boiler. The particle size of biomass can be much larger than that of coal to reach complete burnout due to lower density and greater reactivity. The burner location and the trajectories of the particles might be optimised to maximise the residence time and burnout. (author)

  17. Comparison of pacing algorithms to avoid unnecessary ventricular pacing in patients with sick sinus node syndrome: a single-centre, observational, parallel study.

    Science.gov (United States)

    Poghosyan, Hermine R; Jamalyan, Smbat V

    2012-10-01

    Reduction of unnecessary ventricular pacing (uVP) is an essential component in the treatment strategy in any pacing population in general. The aim of this study was to evaluate the efficacy of different algorithms to reduce uVP in an adult population with sick sinus syndrome (SSS) treated outside of clinical trials. Evaluation of the relationship between different types of pacing algorithms and clinical outcomes is also provided. This was a single-centre, observational, parallel study, based on retrospective analysis of the Arrhythmology Cardiology Center of Armenia electronic clinical database. This study evaluated atrial pacing percentage (AP%), ventricular pacing percentage (VP%), and the incidence of atrial high rate episodes in 56 patients with SSS using three different pacing strategies: managed VP, search atrioventricular (AV), and fixed long AV. We did not find statistically significant differences in the amount of VP between the groups. Although the atrial high rate percentage (AHR%) tended to be higher in the fixed long AV group, this difference was not statistically significant. Mean VP% and AP% were similar in all three groups. In our study, all three programmed strategies produced the same mean AP% and VP%, and were equally efficient in uVP reduction. There was no relationship between chosen algorithms and the incidence of pacemaker syndrome, hospitalizations, or change in New York Heart Association class. The percentage of AHR was not associated with pacing strategy or co-morbidities but showed borderline correlation with left atrial size.

  18. Scanning, Multibeam, Single Photon Lidars for Rapid, Large Scale, High Resolution, Topographic and Bathymetric Mapping

    Directory of Open Access Journals (Sweden)

    John J. Degnan

    2016-11-01

    Full Text Available Several scanning, single photon sensitive, 3D imaging lidars are herein described that operate at aircraft above ground levels (AGLs between 1 and 11 km, and speeds in excess of 200 knots. With 100 beamlets and laser fire rates up to 60 kHz, we, at the Sigma Space Corporation (Lanham, MD, USA, have interrogated up to 6 million ground pixels per second, all of which can record multiple returns from volumetric scatterers such as tree canopies. High range resolution has been achieved through the use of subnanosecond laser pulsewidths, detectors and timing receivers. The systems are presently being deployed on a variety of aircraft to demonstrate their utility in multiple applications including large scale surveying, bathymetry, forestry, etc. Efficient noise filters, suitable for near realtime imaging, have been shown to effectively eliminate the solar background during daytime operations. Geolocation elevation errors measured to date are at the subdecimeter level. Key differences between our Single Photon Lidars, and competing Geiger Mode lidars are also discussed.

  19. Techniques for extracting single-trial activity patterns from large-scale neural recordings

    Science.gov (United States)

    Churchland, Mark M; Yu, Byron M; Sahani, Maneesh; Shenoy, Krishna V

    2008-01-01

    Summary Large, chronically-implanted arrays of microelectrodes are an increasingly common tool for recording from primate cortex, and can provide extracellular recordings from many (order of 100) neurons. While the desire for cortically-based motor prostheses has helped drive their development, such arrays also offer great potential to advance basic neuroscience research. Here we discuss the utility of array recording for the study of neural dynamics. Neural activity often has dynamics beyond that driven directly by the stimulus. While governed by those dynamics, neural responses may nevertheless unfold differently for nominally identical trials, rendering many traditional analysis methods ineffective. We review recent studies – some employing simultaneous recording, some not – indicating that such variability is indeed present both during movement generation, and during the preceding premotor computations. In such cases, large-scale simultaneous recordings have the potential to provide an unprecedented view of neural dynamics at the level of single trials. However, this enterprise will depend not only on techniques for simultaneous recording, but also on the use and further development of analysis techniques that can appropriately reduce the dimensionality of the data, and allow visualization of single-trial neural behavior. PMID:18093826

  20. Scaling of the steady state and stability behaviour of single and two-phase natural circulation systems

    International Nuclear Information System (INIS)

    Vijayan, P.K.; Nayak, A.K.; Bade, M.H.; Kumar, N.; Saha, D.; Sinha, R.K.

    2002-01-01

    Scaling methods for both single-phase and two-phase natural circulation systems have been presented. For single-phase systems, simulation of the steady state flow can be achieved by preserving just one nondimensional parameter. For uniform diameter two-phase systems also, it is possible to simulate the steady state behaviour with just one non-dimensional parameter. Simulation of the stability behaviour requires geometric similarity in addition to the similarity of the physical parameters appearing in the governing equations. The scaling laws proposed have been tested with experimental data in case of single-phase natural circulation. (author)

  1. Solar radiation transmissivity of a single-span greenhouse through measurements on scale models

    International Nuclear Information System (INIS)

    Papadakis, G.; Manolakos, D.; Kyritsis, S.

    1998-01-01

    The solar transmissivity of a single-span greenhouse has been investigated experimentally using a scale model, of dimensions 40 cm width and 80 cm length. The solar transmissivity was measured at 48 positions on the “ground” surface of the scale model using 48 small silicon solar cells. The greenhouse model was positioned horizontally on a specially made goniometric mechanism. In this way, the greenhouse azimuth could be changed so that typical days of the year could be simulated using different combinations of greenhouse azimuth and the position of the sun in the sky. The measured solar transmissivity distribution at the “ground” surface and the average greenhouse solar transmissivity are presented and analysed, for characteristic days of the year, for winter and summer for a latitude of 37°58′ (Athens, Greece). It is shown that for the latitude of 37°58′ N during winter, the E–W orientation is preferable to the N–S one. The side walls, and especially the East and West ones for the E–W orientation, reduce considerably the greenhouse transmissivity at areas close to the walls for long periods of the day when the angle of incidence of the solar rays to these walls is large. (author)

  2. Quantifying streamflow change caused by forest disturbance at a large spatial scale: A single watershed study

    Science.gov (United States)

    Wei, Xiaohua; Zhang, Mingfang

    2010-12-01

    Climatic variability and forest disturbance are commonly recognized as two major drivers influencing streamflow change in large-scale forested watersheds. The greatest challenge in evaluating quantitative hydrological effects of forest disturbance is the removal of climatic effect on hydrology. In this paper, a method was designed to quantify respective contributions of large-scale forest disturbance and climatic variability on streamflow using the Willow River watershed (2860 km2) located in the central part of British Columbia, Canada. Long-term (>50 years) data on hydrology, climate, and timber harvesting history represented by equivalent clear-cutting area (ECA) were available to discern climatic and forestry influences on streamflow by three steps. First, effective precipitation, an integrated climatic index, was generated by subtracting evapotranspiration from precipitation. Second, modified double mass curves were developed by plotting accumulated annual streamflow against annual effective precipitation, which presented a much clearer picture of the cumulative effects of forest disturbance on streamflow following removal of climatic influence. The average annual streamflow changes that were attributed to forest disturbances and climatic variability were then estimated to be +58.7 and -72.4 mm, respectively. The positive (increasing) and negative (decreasing) values in streamflow change indicated opposite change directions, which suggest an offsetting effect between forest disturbance and climatic variability in the study watershed. Finally, a multivariate Autoregressive Integrated Moving Average (ARIMA) model was generated to establish quantitative relationships between accumulated annual streamflow deviation attributed to forest disturbances and annual ECA. The model was then used to project streamflow change under various timber harvesting scenarios. The methodology can be effectively applied to any large-scale single watershed where long-term data (>50

  3. Synthesis of Large-Scale Single-Crystalline Monolayer WS2 Using a Semi-Sealed Method

    Directory of Open Access Journals (Sweden)

    Feifei Lan

    2018-02-01

    Full Text Available As a two-dimensional semiconductor, WS2 has attracted great attention due to its rich physical properties and potential applications. However, it is still difficult to synthesize monolayer single-crystalline WS2 at larger scale. Here, we report the growth of large-scale triangular single-crystalline WS2 with a semi-sealed installation by chemical vapor deposition (CVD. Through this method, triangular single-crystalline WS2 with an average length of more than 300 µm was obtained. The largest one was about 405 μm in length. WS2 triangles with different sizes and thicknesses were analyzed by optical microscope and atomic force microscope (AFM. Their optical properties were evaluated by Raman and photoluminescence (PL spectra. This report paves the way to fabricating large-scale single-crystalline monolayer WS2, which is useful for the growth of high-quality WS2 and its potential applications in the future.

  4. Intelligent Mission Controller Node

    National Research Council Canada - National Science Library

    Perme, David

    2002-01-01

    The goal of the Intelligent Mission Controller Node (IMCN) project was to improve the process of translating mission taskings between real-world Command, Control, Communications, Computers, and Intelligence (C41...

  5. Lymph node culture

    Science.gov (United States)

    Culture - lymph node ... or viruses grow. This process is called a culture. Sometimes, special stains are also used to identify specific cells or microorganisms before culture results are available. If needle aspiration does not ...

  6. High-Accuracy Elevation Data at Large Scales from Airborne Single-Pass SAR Interferometry

    Directory of Open Access Journals (Sweden)

    Guy Jean-Pierre Schumann

    2016-01-01

    Full Text Available Digital elevation models (DEMs are essential data sets for disaster risk management and humanitarian relief services as well as many environmental process models. At present, on the hand, globally available DEMs only meet the basic requirements and for many services and modeling studies are not of high enough spatial resolution and lack accuracy in the vertical. On the other hand, LiDAR-DEMs are of very high spatial resolution and great vertical accuracy but acquisition operations can be very costly for spatial scales larger than a couple of hundred square km and also have severe limitations in wetland areas and under cloudy and rainy conditions. The ideal situation would thus be to have a DEM technology that allows larger spatial coverage than LiDAR but without compromising resolution and vertical accuracy and still performing under some adverse weather conditions and at a reasonable cost. In this paper, we present a novel single pass In-SAR technology for airborne vehicles that is cost-effective and can generate DEMs with a vertical error of around 0.3 m for an average spatial resolution of 3 m. To demonstrate this capability, we compare a sample single-pass In-SAR Ka-band DEM of the California Central Valley from the NASA/JPL airborne GLISTIN-A to a high-resolution LiDAR DEM. We also perform a simple sensitivity analysis to floodplain inundation. Based on the findings of our analysis, we argue that this type of technology can and should be used to replace large regions of globally available lower resolution DEMs, particularly in coastal, delta and floodplain areas where a high number of assets, habitats and lives are at risk from natural disasters. We conclude with a discussion on requirements, advantages and caveats in terms of instrument and data processing.

  7. Does the Assessment of Recovery Capital scale reflect a single or multiple domains?

    Science.gov (United States)

    Arndt, Stephan; Sahker, Ethan; Hedden, Suzy

    2017-01-01

    The goal of this study was to determine whether the 50-item Assessment of Recovery Capital scale represents a single general measure or whether multiple domains might be psychometrically useful for research or clinical applications. Data are from a cross-sectional de-identified existing program evaluation information data set with 1,138 clients entering substance use disorder treatment. Principal components and iterated factor analysis were used on the domain scores. Multiple group factor analysis provided a quasi-confirmatory factor analysis. The solution accounted for 75.24% of the total variance, suggesting that 10 factors provide a reasonably good fit. However, Tucker's congruence coefficients between the factor structure and defining weights (0.41-0.52) suggested a poor fit to the hypothesized 10-domain structure. Principal components of the 10-domain scores yielded one factor whose eigenvalue was greater than one (5.93), accounting for 75.8% of the common variance. A few domains had perceptible but small unique variance components suggesting that a few of the domains may warrant enrichment. Our findings suggest that there is one general factor, with a caveat. Using the 10 measures inflates the chance for Type I errors. Using one general measure avoids this issue, is simple to interpret, and could reduce the number of items. However, those seeking to maximally predict later recovery success may need to use the full instrument and all 10 domains.

  8. Ultra-High Density Single Nanometer-Scale Anodic Alumina Nanofibers Fabricated by Pyrophosphoric Acid Anodizing

    Science.gov (United States)

    Kikuchi, Tatsuya; Nishinaga, Osamu; Nakajima, Daiki; Kawashima, Jun; Natsui, Shungo; Sakaguchi, Norihito; Suzuki, Ryosuke O.

    2014-12-01

    Anodic oxide fabricated by anodizing has been widely used for nanostructural engineering, but the nanomorphology is limited to only two oxides: anodic barrier and porous oxides. Therefore, the discovery of an additional anodic oxide with a unique nanofeature would expand the applicability of anodizing. Here we demonstrate the fabrication of a third-generation anodic oxide, specifically, anodic alumina nanofibers, by anodizing in a new electrolyte, pyrophosphoric acid. Ultra-high density single nanometer-scale anodic alumina nanofibers (1010 nanofibers/cm2) consisting of an amorphous, pure aluminum oxide were successfully fabricated via pyrophosphoric acid anodizing. The nanomorphologies of the anodic nanofibers can be controlled by the electrochemical conditions. Anodic tungsten oxide nanofibers can also be fabricated by pyrophosphoric acid anodizing. The aluminum surface covered by the anodic alumina nanofibers exhibited ultra-fast superhydrophilic behavior, with a contact angle of less than 1°, within 1 second. Such ultra-narrow nanofibers can be used for various nanoapplications including catalysts, wettability control, and electronic devices.

  9. A robust single-beam optical trap for a gram-scale mechanical oscillator.

    Science.gov (United States)

    Altin, P A; Nguyen, T T-H; Slagmolen, B J J; Ward, R L; Shaddock, D A; McClelland, D E

    2017-11-06

    Precise optical control of microscopic particles has been mastered over the past three decades, with atoms, molecules and nano-particles now routinely trapped and cooled with extraordinary precision, enabling rapid progress in the study of quantum phenomena. Achieving the same level of control over macroscopic objects is expected to bring further advances in precision measurement, quantum information processing and fundamental tests of quantum mechanics. However, cavity optomechanical systems dominated by radiation pressure - so-called 'optical springs' - are inherently unstable due to the delayed dynamical response of the cavity. Here we demonstrate a fully stable, single-beam optical trap for a gram-scale mechanical oscillator. The interaction of radiation pressure with thermo-optic feedback generates damping that exceeds the mechanical loss by four orders of magnitude. The stability of the resultant spring is robust to changes in laser power and detuning, and allows purely passive self-locking of the cavity. Our results open up a new way of trapping and cooling macroscopic objects for optomechanical experiments.

  10. Large-scale synthesis of single-crystalline MgO with bone-like nanostructures

    International Nuclear Information System (INIS)

    Niu Haixia; Yang Qing; Tang Kaibin; Xie Yi

    2006-01-01

    Uniform bone-like MgO nanocrystals have been prepared via a solvothermal process using commercial Mg powders as the starting material in the absence of any catalyst or surfactant followed by a subsequent calcination. Field emission scanning electron microscopy (FE-SEM) and transmission electron microscopy (TEM) measurements indicate that the product consists of a large quantity of bone-like nanocrystals with lengths of 120-200 nm. The widths of these nanocrystals at both ends are in the range of 20-50 nm, which are 3-20 nm wider than those of the middle parts. Explorations of X-ray diffraction (XRD) and selected area electronic diffraction (SAED) exhibit that the product is high-quality cubic single-crystalline nanocrystals. The photoluminescence (PL) measurement suggests that the product has an intensive emission centered at 410 nm, showing that the product has potential application in optical devices. The advantages of our method lie in high yield, the easy availability of the starting materials and permitting large-scale production at low cost. The growth mechanism was proposed to be related with solvent's oxidation in the precursor formation process and following nucleation and mass-transfer in the decomposition of the precursor

  11. Large-scale separation of single-walled carbon nanotubes by electronic type using click chemistry

    Science.gov (United States)

    Um, Jo-Eun; Song, Sun Gu; Yoo, Pil J.; Song, Changsik; Kim, Woo-Jae

    2018-01-01

    Single-walled carbon nanotubes (SWCNTs) can be either metallic or semiconducting, making their separation critical for applications in nanoelectronics, biomedical materials, and solar cells. Herein, we investigate a novel solution-phase separation method based on click chemistry (azide-alkyne Huisgen cycloaddition) and determine its efficiency and scalability. In this method, metallic SWCNTs in metallic/semiconducting SWCNT mixtures are selectively functionalized with alkyne groups by being reacted with 4-propargyloxybenezenediazonium tetrafluoroborate. Subsequently, silica nanoparticles are functionalized with azide groups and reacted with alkyne-bearing metallic SWCNTs in the SWCNT mixture in the presence of a Cu catalyst. As a result, metallic SWCNTs are anchored on silica powder, whereas non-functionalized semiconducting SWCNTs remain in solution. Low-speed centrifugation effectively removes the silica powder with attached metallic SWCNTs, furnishing a solution of highly pure semiconducting SWCNTs, as confirmed by Raman and UV-vis/near-infrared absorption measurements. This novel separation scheme exhibits the advantage of simultaneously separating both metallic and semiconducting SWCNTs from their mixtures, being cost-effective and therefore applicable at an industrial scale.

  12. Flight Tests of a 0.13-Scale Model of the Convair XFY-1 Vertically Rising Airplane with the Lower Vertical Tail Removed, TED No.DE 368

    Science.gov (United States)

    Lovell, Powell M., Jr.

    1954-01-01

    An experimental investigation has been conducted to determine the dynamic stability and control characteristics in hovering and transition flight of a 0.13-scale flying model of the Convair XFY-1 vertically rising airplane with the lower vertical tail removed. The purpose of the tests was to obtain a general indication of the behavior of a vertically rising airplane of the same general type as the XFY-1 but without a lower vertical tail in order to simplify power-off belly landings in an emergency. The model was flown satisfactorily in hovering flight and in the transition from hovering to normal unstalled forward flight (angle of attack approximately 30deg). From an angle of attack of about 30 down to the lowest angle of attack covered in the flight tests (approximately 15deg) the model became progressively more difficult to control. These control difficulties were attributed partly to a lightly damped Dutch roll oscillation and partly to the fact that the control deflections required for hovering and transition flight were too great for smooth flight at high speeds. In the low-angle-of-attack range not covered in the flight tests, force tests have indicated very low static directional stability which would probably result in poor flight characteristics. It appears, therefore, that the attainment of satisfactory directional stability, at angles of attack less than 10deg, rather than in the hovering and transition ranges of flight is the critical factor in the design of the vertical tail for such a configuration.

  13. Single and two-phase similarity analysis of a reduced-scale natural convection loop relative to a full-scale prototype

    International Nuclear Information System (INIS)

    Botelho, David A.; Faccini, Jose L.H.

    2002-01-01

    The main topic in this paper is a new device being considered to improve nuclear reactor safety employing the natural circulation. A scaled experiment used to demonstrate the performance of the device is also described. We also applied a similarity analysis method for single and two-phase natural convection loop flow to the IEN CCN experiment and to an APEX like experiment to verify the degree of similarity relative to a full-scale prototype like the AP600. Most of the CCN similarity numbers that represent important single and two-phase similarity conditions are comparable to the APEX like loop non-dimensional numbers calculated employing the same methodology. Despite the much smaller geometric, pressure, and power scales, we conclude that the IEN CCN has single and two-phase natural circulation similarity numbers that represent fairly well the full-scale prototype. even lacking most complementary primary and safety systems, this IEN circuit provided a much valid experience to develop human, experimental, and analytical resources, besides its utilization as a training tool. (author)

  14. Instant node package module

    CERN Document Server

    Ali, Juzer

    2013-01-01

    Get to grips with a new technology, understand what it is and what it can do for you, and then get to work with the most important features and tasks. A practical exploration of the lifecycle of creating node modules as well as learning all of the top features that npm has to offer.Intended for readers who want to create their first node.js modules. The programming paradigm of JavaScript is not covered so a foundation in these concepts would be beneficial.

  15. Does the Assessment of Recovery Capital scale reflect a single or multiple domains?

    Directory of Open Access Journals (Sweden)

    Arndt S

    2017-07-01

    Full Text Available Stephan Arndt,1–3 Ethan Sahker,1,4 Suzy Hedden1 1Iowa Consortium for Substance Abuse Research and Evaluation, 2Department of Psychiatry, Carver College of Medicine, 3Department of Biostatistics, College of Public Health, 4Department of Psychological and Quantitative Foundations, Counseling Psychology Program College of Education, University of Iowa, Iowa City, IA, USA Objective: The goal of this study was to determine whether the 50-item Assessment of Recovery Capital scale represents a single general measure or whether multiple domains might be psychometrically useful for research or clinical applications. Methods: Data are from a cross-sectional de-identified existing program evaluation information data set with 1,138 clients entering substance use disorder treatment. Principal components and iterated factor analysis were used on the domain scores. Multiple group factor analysis provided a quasi-confirmatory factor analysis. Results: The solution accounted for 75.24% of the total variance, suggesting that 10 factors provide a reasonably good fit. However, Tucker’s congruence coefficients between the factor structure and defining weights (0.41–0.52 suggested a poor fit to the hypothesized 10-domain structure. Principal components of the 10-domain scores yielded one factor whose eigenvalue was greater than one (5.93, accounting for 75.8% of the common variance. A few domains had perceptible but small unique variance components suggesting that a few of the domains may warrant enrichment. Conclusion: Our findings suggest that there is one general factor, with a caveat. Using the 10 measures inflates the chance for Type I errors. Using one general measure avoids this issue, is simple to interpret, and could reduce the number of items. However, those seeking to maximally predict later recovery success may need to use the full instrument and all 10 domains. Keywords: social support, psychometrics, quality of life

  16. Single-tube hydroponics as a novel idea for small-scale production of crop seed in a plant incubator.

    Science.gov (United States)

    Kuroda, Masaharu; Ikenaga, Sachiko

    2015-01-01

    We present a novel protocol for small-scale production of crop seed in a plant incubator termed "Single-tube hydroponics." Our protocol minimizes the materials and methods for cultivation whereby a large number of independent plants can be cultured in a limited space. This study may aid in the improvement of crop seed components, especially in the cultivation of transgenic plants.

  17. Large-scale membrane transfer process: its application to single-crystal-silicon continuous membrane deformable mirror

    International Nuclear Information System (INIS)

    Wu, Tong; Sasaki, Takashi; Hane, Kazuhiro; Akiyama, Masayuki

    2013-01-01

    This paper describes a large-scale membrane transfer process developed for the construction of large-scale membrane devices via the transfer of continuous single-crystal-silicon membranes from one substrate to another. This technique is applied for fabricating a large stroke deformable mirror. A bimorph spring array is used to generate a large air gap between the mirror membrane and the electrode. A 1.9 mm × 1.9 mm × 2 µm single-crystal-silicon membrane is successfully transferred to the electrode substrate by Au–Si eutectic bonding and the subsequent all-dry release process. This process provides an effective approach for transferring a free-standing large continuous single-crystal-silicon to a flexible suspension spring array with a large air gap. (paper)

  18. Comparison of single- and multi-scale models for the prediction of the Culicoides biting midge distribution in Germany

    Directory of Open Access Journals (Sweden)

    Renke Lühken

    2016-05-01

    Full Text Available This study analysed Culicoides presence-absence data from 46 sampling sites in Germany, where monitoring was carried out from April 2007 until May 2008. Culicoides presence-absence data were analysed in relation to land cover data, in order to study whether the prevalence of biting midges is correlated to land cover data with respect to the trapping sites. We differentiated eight scales, i.e. buffer zones with radii of 0.5, 1, 2, 3, 4, 5, 7.5 and 10 km, around each site, and chose several land cover variables. For each species, we built eight single-scale models (i.e. predictor variables from one of the eight scales for each model based on averaged, generalised linear models and two multiscale models (i.e. predictor variables from all of the eight scales based on averaged, generalised linear models and generalised linear models with random forest variable selection. There were no significant differences between performance indicators of models built with land cover data from different buffer zones around the trapping sites. However, the overall performance of multi-scale models was higher than the alternatives. Furthermore, these models mostly achieved the best performance for the different species using the index area under the receiver operating characteristic curve. However, as also presented in this study, the relevance of the different variables could significantly differ between various scales, including the number of species affected and the positive or negative direction. This is an even more severe problem if multi-scale models are concerned, in which one model can have the same variable at different scales but with different directions, i.e. negative and positive direction of the same variable at different scales. However, multi-scale modelling is a promising approach to model the distribution of Culicoides species, accounting much more for the ecology of biting midges, which uses different resources (breeding sites, hosts, etc. at

  19. Active sensing and its application to sensor node reconfiguration.

    Science.gov (United States)

    Lee, Sooyong

    2014-10-08

    This paper presents a perturbation/correlation-based active sensing method and its application to sensor node configuration for environment monitoring. Sensor networks are widely used as data measurement tools, especially in dangerous environments. For large scale environment monitoring, a large number of nodes is required. For optimal measurements, the placement of nodes is very important. Nonlinear spring force-based configuration is introduced. Perturbation/correlation-based estimation of the gradient is developed and it is much more robust because it does not require any differentiation. An algorithm for tuning the stiffness using the estimated gradient for node reconfiguration is presented. The performance of the proposed algorithm is discussed with simulation results.

  20. Involved Node Radiation Therapy

    DEFF Research Database (Denmark)

    Maraldo, Maja V; Aznar, Marianne C; Vogelius, Ivan R

    2012-01-01

    PURPOSE: The involved node radiation therapy (INRT) strategy was introduced for patients with Hodgkin lymphoma (HL) to reduce the risk of late effects. With INRT, only the originally involved lymph nodes are irradiated. We present treatment outcome in a retrospective analysis using this strategy...... to 36 Gy). Patients attended regular follow-up visits until 5 years after therapy. RESULTS: The 4-year freedom from disease progression was 96.4% (95% confidence interval: 92.4%-100.4%), median follow-up of 50 months (range: 4-71 months). Three relapses occurred: 2 within the previous radiation field......, and 1 in a previously uninvolved region. The 4-year overall survival was 94% (95% confidence interval: 88.8%-99.1%), median follow-up of 58 months (range: 4-91 months). Early radiation therapy toxicity was limited to grade 1 (23.4%) and grade 2 (13.8%). During follow-up, 8 patients died, none from HL, 7...

  1. Node web development

    CERN Document Server

    Herron, David

    2013-01-01

    Presented in a simple, step-by-step format, this book is an introduction to web development with Node.This book is for anybody looking for an alternative to the ""P"" languages (Perl, PHP, Python), or anyone looking for a new paradigm of server-side application development.The reader should have at least a rudimentary understanding of JavaScript and web application development.

  2. Status of lymph node staging

    NARCIS (Netherlands)

    Nieweg, O. E.; Estourgie, S. H.; Deurloo, E. E.; Rutgers, E. J. Th; Kroon, B. B. R.

    2002-01-01

    Sentinel node biopsy has the potential to provide more accurate staging information than axillary node dissection. Given the considerable morbidity of axillary node dissection this less invasive approach is attractive. However, there are a number of issues to be resolved before the best technique of

  3. Neoclassical theory of electromagnetic interactions a single theory for macroscopic and microscopic scales

    CERN Document Server

    Babin, Anatoli

    2016-01-01

    In this monograph, the authors present their recently developed theory of electromagnetic interactions. This neoclassical approach extends the classical electromagnetic theory down to atomic scales and allows the explanation of various non-classical phenomena in the same framework. While the classical Maxwell–Lorentz electromagnetism theory succeeds in describing the physical reality at macroscopic scales, it struggles at atomic scales. Here, quantum mechanics traditionally takes over to describe non-classical phenomena such as the hydrogen spectrum and de Broglie waves. By means of modifying the classical theory, the approach presented here is able to consistently explain quantum-mechanical effects, and while similar to quantum mechanics in some respects, this neoclassical theory also differs markedly from it. In particular, the newly developed framework omits probabilistic interpretations of the wave function and features a new fundamental spatial scale which, at the size of the free electron, is much lar...

  4. Single hadron response measurement and calorimeter jet energy scale uncertainty with the ATLAS detector at the LHC

    CERN Document Server

    Aad, Georges; Abdallah, Jalal; Abdelalim, Ahmed Ali; Abdesselam, Abdelouahab; Abdinov, Ovsat; Abi, Babak; Abolins, Maris; AbouZeid, Ossama; Abramowicz, Halina; Abreu, Henso; Acerbi, Emilio; Acharya, Bobby Samir; Adamczyk, Leszek; Adams, David; Addy, Tetteh; Adelman, Jahred; Aderholz, Michael; Adomeit, Stefanie; Adragna, Paolo; Adye, Tim; Aefsky, Scott; Aguilar-Saavedra, Juan Antonio; Aharrouche, Mohamed; Ahlen, Steven; Ahles, Florian; Ahmad, Ashfaq; Ahsan, Mahsana; Aielli, Giulio; Akdogan, Taylan; Åkesson, Torsten Paul Ake; Akimoto, Ginga; Akimov, Andrei; Akiyama, Kunihiro; Alam, Mohammad; Alam, Muhammad Aftab; Albert, Justin; Albrand, Solveig; Aleksa, Martin; Aleksandrov, Igor; Alessandria, Franco; Alexa, Calin; Alexander, Gideon; Alexandre, Gauthier; Alexopoulos, Theodoros; Alhroob, Muhammad; Aliev, Malik; Alimonti, Gianluca; Alison, John; Aliyev, Magsud; Allbrooke, Benedict; Allport, Phillip; Allwood-Spiers, Sarah; Almond, John; Aloisio, Alberto; Alon, Raz; Alonso, Alejandro; Alvarez Gonzalez, Barbara; Alviggi, Mariagrazia; Amako, Katsuya; Amaral, Pedro; Amelung, Christoph; Ammosov, Vladimir; Amorim, Antonio; Amorós, Gabriel; Amram, Nir; Anastopoulos, Christos; Ancu, Lucian Stefan; Andari, Nansi; Andeen, Timothy; Anders, Christoph Falk; Anders, Gabriel; Anderson, Kelby; Andreazza, Attilio; Andrei, George Victor; Andrieux, Marie-Laure; Anduaga, Xabier; Angerami, Aaron; Anghinolfi, Francis; Anisenkov, Alexey; Anjos, Nuno; Annovi, Alberto; Antonaki, Ariadni; Antonelli, Mario; Antonov, Alexey; Antos, Jaroslav; Anulli, Fabio; Aoun, Sahar; Aperio Bella, Ludovica; Apolle, Rudi; Arabidze, Giorgi; Aracena, Ignacio; Arai, Yasuo; Arce, Ayana; Arfaoui, Samir; Arguin, Jean-Francois; Arik, Engin; Arik, Metin; Armbruster, Aaron James; Arnaez, Olivier; Arnault, Christian; Artamonov, Andrei; Artoni, Giacomo; Arutinov, David; Asai, Shoji; Asfandiyarov, Ruslan; Ask, Stefan; Åsman, Barbro; Asquith, Lily; Assamagan, Ketevi; Astbury, Alan; Astvatsatourov, Anatoli; Aubert, Bernard; Auge, Etienne; Augsten, Kamil; Aurousseau, Mathieu; Avolio, Giuseppe; Avramidou, Rachel Maria; Axen, David; Ay, Cano; Azuelos, Georges; Azuma, Yuya; Baak, Max; Baccaglioni, Giuseppe; Bacci, Cesare; Bach, Andre; Bachacou, Henri; Bachas, Konstantinos; Backes, Moritz; Backhaus, Malte; Badescu, Elisabeta; Bagnaia, Paolo; Bahinipati, Seema; Bai, Yu; Bailey, David; Bain, Travis; Baines, John; Baker, Oliver Keith; Baker, Mark; Baker, Sarah; Banas, Elzbieta; Banerjee, Piyali; Banerjee, Swagato; Banfi, Danilo; Bangert, Andrea Michelle; Bansal, Vikas; Bansil, Hardeep Singh; Barak, Liron; Baranov, Sergei; Barashkou, Andrei; Barbaro Galtieri, Angela; Barber, Tom; Barberio, Elisabetta Luigia; Barberis, Dario; Barbero, Marlon; Bardin, Dmitri; Barillari, Teresa; Barisonzi, Marcello; Barklow, Timothy; Barlow, Nick; Barnett, Bruce; Barnett, Michael; Baroncelli, Antonio; Barone, Gaetano; Barr, Alan; Barreiro, Fernando; Barreiro Guimarães da Costa, João; Barrillon, Pierre; Bartoldus, Rainer; Barton, Adam Edward; Bartsch, Valeria; Bates, Richard; Batkova, Lucia; Batley, Richard; Battaglia, Andreas; Battistin, Michele; Bauer, Florian; Bawa, Harinder Singh; Beale, Steven; Beau, Tristan; Beauchemin, Pierre-Hugues; Beccherle, Roberto; Bechtle, Philip; Beck, Hans Peter; Becker, Sebastian; Beckingham, Matthew; Becks, Karl-Heinz; Beddall, Andrew; Beddall, Ayda; Bedikian, Sourpouhi; Bednyakov, Vadim; Bee, Christopher; Begel, Michael; Behar Harpaz, Silvia; Behera, Prafulla; Beimforde, Michael; Belanger-Champagne, Camille; Bell, Paul; Bell, William; Bella, Gideon; Bellagamba, Lorenzo; Bellina, Francesco; Bellomo, Massimiliano; Belloni, Alberto; Beloborodova, Olga; Belotskiy, Konstantin; Beltramello, Olga; Ben Ami, Sagi; Benary, Odette; Benchekroun, Driss; Benchouk, Chafik; Bendel, Markus; Benekos, Nektarios; Benhammou, Yan; Benhar Noccioli, Eleonora; Benitez Garcia, Jorge-Armando; Benjamin, Douglas; Benoit, Mathieu; Bensinger, James; Benslama, Kamal; Bentvelsen, Stan; Berge, David; Bergeaas Kuutmann, Elin; Berger, Nicolas; Berghaus, Frank; Berglund, Elina; Beringer, Jürg; Bernat, Pauline; Bernhard, Ralf; Bernius, Catrin; Berry, Tracey; Bertella, Claudia; Bertin, Antonio; Bertinelli, Francesco; Bertolucci, Federico; Besana, Maria Ilaria; Besson, Nathalie; Bethke, Siegfried; Bhimji, Wahid; Bianchi, Riccardo-Maria; Bianco, Michele; Biebel, Otmar; Bieniek, Stephen Paul; Bierwagen, Katharina; Biesiada, Jed; Biglietti, Michela; Bilokon, Halina; Bindi, Marcello; Binet, Sebastien; Bingul, Ahmet; Bini, Cesare; Biscarat, Catherine; Bitenc, Urban; Black, Kevin; Blair, Robert; Blanchard, Jean-Baptiste; Blanchot, Georges; Blazek, Tomas; Blocker, Craig; Blocki, Jacek; Blondel, Alain; Blum, Walter; Blumenschein, Ulrike; Bobbink, Gerjan; Bobrovnikov, Victor; Bocchetta, Simona Serena; Bocci, Andrea; Boddy, Christopher Richard; Boehler, Michael; Boek, Jennifer; Boelaert, Nele; Bogaerts, Joannes Andreas; Bogdanchikov, Alexander; Bogouch, Andrei; Bohm, Christian; Boisvert, Veronique; Bold, Tomasz; Boldea, Venera; Bolnet, Nayanka Myriam; Bona, Marcella; Bondarenko, Valery; Bondioli, Mario; Boonekamp, Maarten; Booth, Chris; Bordoni, Stefania; Borer, Claudia; Borisov, Anatoly; Borissov, Guennadi; Borjanovic, Iris; Borri, Marcello; Borroni, Sara; Bortolotto, Valerio; Bos, Kors; Boscherini, Davide; Bosman, Martine; Boterenbrood, Hendrik; Botterill, David; Bouchami, Jihene; Boudreau, Joseph; Bouhova-Thacker, Evelina Vassileva; Boumediene, Djamel Eddine; Bourdarios, Claire; Bousson, Nicolas; Boveia, Antonio; Boyd, James; Boyko, Igor; Bozhko, Nikolay; Bozovic-Jelisavcic, Ivanka; Bracinik, Juraj; Braem, André; Branchini, Paolo; Brandenburg, George; Brandt, Andrew; Brandt, Gerhard; Brandt, Oleg; Bratzler, Uwe; Brau, Benjamin; Brau, James; Braun, Helmut; Brelier, Bertrand; Bremer, Johan; Brenner, Richard; Bressler, Shikma; Britton, Dave; Brochu, Frederic; Brock, Ian; Brock, Raymond; Brodbeck, Timothy; Brodet, Eyal; Broggi, Francesco; Bromberg, Carl; Bronner, Johanna; Brooijmans, Gustaaf; Brooks, William; Brown, Gareth; Brown, Heather; Bruckman de Renstrom, Pawel; Bruncko, Dusan; Bruneliere, Renaud; Brunet, Sylvie; Bruni, Alessia; Bruni, Graziano; Bruschi, Marco; Buanes, Trygve; Buat, Quentin; Bucci, Francesca; Buchanan, James; Buchanan, Norman; Buchholz, Peter; Buckingham, Ryan; Buckley, Andrew; Buda, Stelian Ioan; Budagov, Ioulian; Budick, Burton; Büscher, Volker; Bugge, Lars; Bulekov, Oleg; Bunse, Moritz; Buran, Torleiv; Burckhart, Helfried; Burdin, Sergey; Burgard, Carsten Daniel; Burgess, Thomas; Burke, Stephen; Busato, Emmanuel; Bussey, Peter; Buszello, Claus-Peter; Butin, François; Butler, Bart; Butler, John; Buttar, Craig; Butterworth, Jonathan; Buttinger, William; Cabrera Urbán, Susana; Caforio, Davide; Cakir, Orhan; Calafiura, Paolo; Calderini, Giovanni; Calfayan, Philippe; Calkins, Robert; Caloba, Luiz; Caloi, Rita; Calvet, David; Calvet, Samuel; Camacho Toro, Reina; Camarri, Paolo; Cambiaghi, Mario; Cameron, David; Caminada, Lea Michaela; Campana, Simone; Campanelli, Mario; Canale, Vincenzo; Canelli, Florencia; Canepa, Anadi; Cantero, Josu; Capasso, Luciano; Capeans Garrido, Maria Del Mar; Caprini, Irinel; Caprini, Mihai; Capriotti, Daniele; Capua, Marcella; Caputo, Regina; Caramarcu, Costin; Cardarelli, Roberto; Carli, Tancredi; Carlino, Gianpaolo; Carminati, Leonardo; Caron, Bryan; Caron, Sascha; Carrillo Montoya, German D; Carter, Antony; Carter, Janet; Carvalho, João; Casadei, Diego; Casado, Maria Pilar; Cascella, Michele; Caso, Carlo; Castaneda Hernandez, Alfredo Martin; Castaneda-Miranda, Elizabeth; Castillo Gimenez, Victoria; Castro, Nuno Filipe; Cataldi, Gabriella; Cataneo, Fernando; Catinaccio, Andrea; Catmore, James; Cattai, Ariella; Cattani, Giordano; Caughron, Seth; Cauz, Diego; Cavalleri, Pietro; Cavalli, Donatella; Cavalli-Sforza, Matteo; Cavasinni, Vincenzo; Ceradini, Filippo; Santiago Cerqueira, Augusto; Cerri, Alessandro; Cerrito, Lucio; Cerutti, Fabio; Cetin, Serkant Ali; Cevenini, Francesco; Chafaq, Aziz; Chakraborty, Dhiman; Chan, Kevin; Chapleau, Bertrand; Chapman, John Derek; Chapman, John Wehrley; Chareyre, Eve; Charlton, Dave; Chavda, Vikash; Chavez Barajas, Carlos Alberto; Cheatham, Susan; Chekanov, Sergei; Chekulaev, Sergey; Chelkov, Gueorgui; Chelstowska, Magda Anna; Chen, Chunhui; Chen, Hucheng; Chen, Shenjian; Chen, Tingyang; Chen, Xin; Cheng, Shaochen; Cheplakov, Alexander; Chepurnov, Vladimir; Cherkaoui El Moursli, Rajaa; Chernyatin, Valeriy; Cheu, Elliott; Cheung, Sing-Leung; Chevalier, Laurent; Chiefari, Giovanni; Chikovani, Leila; Childers, John Taylor; Chilingarov, Alexandre; Chiodini, Gabriele; Chisholm, Andrew; Chizhov, Mihail; Choudalakis, Georgios; Chouridou, Sofia; Christidi, Illectra-Athanasia; Christov, Asen; Chromek-Burckhart, Doris; Chu, Ming-Lee; Chudoba, Jiri; Ciapetti, Guido; Ciba, Krzysztof; Ciftci, Abbas Kenan; Ciftci, Rena; Cinca, Diane; Cindro, Vladimir; Ciobotaru, Matei Dan; Ciocca, Claudia; Ciocio, Alessandra; Cirilli, Manuela; Citterio, Mauro; Ciubancan, Mihai; Clark, Allan G; Clark, Philip James; Cleland, Bill; Clemens, Jean-Claude; Clement, Benoit; Clement, Christophe; Clifft, Roger; Coadou, Yann; Cobal, Marina; Coccaro, Andrea; Cochran, James H; Coe, Paul; Cogan, Joshua Godfrey; Coggeshall, James; Cogneras, Eric; Colas, Jacques; Colijn, Auke-Pieter; Collard, Caroline; Collins, Neil; Collins-Tooth, Christopher; Collot, Johann; Colon, German; Conde Muiño, Patricia; Coniavitis, Elias; Conidi, Maria Chiara; Consonni, Michele; Consorti, Valerio; Constantinescu, Serban; Conta, Claudio; Conventi, Francesco; Cook, James; Cooke, Mark; Cooper, Ben; Cooper-Sarkar, Amanda; Copic, Katherine; Cornelissen, Thijs; Corradi, Massimo; Corriveau, Francois; Cortes-Gonzalez, Arely; Cortiana, Giorgio; Costa, Giuseppe; Costa, María José; Costanzo, Davide; Costin, Tudor; Côté, David; Coura Torres, Rodrigo; Courneyea, Lorraine; Cowan, Glen; Cowden, Christopher; Cox, Brian; Cranmer, Kyle; Crescioli, Francesco; Cristinziani, Markus; Crosetti, Giovanni; Crupi, Roberto; Crépé-Renaudin, Sabine; Cuciuc, Constantin-Mihai; Cuenca Almenar, Cristóbal; Cuhadar Donszelmann, Tulay; Curatolo, Maria; Curtis, Chris; Cuthbert, Cameron; Cwetanski, Peter; Czirr, Hendrik; Czodrowski, Patrick; Czyczula, Zofia; D'Auria, Saverio; D'Onofrio, Monica; D'Orazio, Alessia; Da Silva, Paulo Vitor; Da Via, Cinzia; Dabrowski, Wladyslaw; Dai, Tiesheng; Dallapiccola, Carlo; Dam, Mogens; Dameri, Mauro; Damiani, Daniel; Danielsson, Hans Olof; Dannheim, Dominik; Dao, Valerio; Darbo, Giovanni; Darlea, Georgiana Lavinia; Davey, Will; Davidek, Tomas; Davidson, Nadia; Davidson, Ruth; Davies, Eleanor; Davies, Merlin; Davison, Adam; Davygora, Yuriy; Dawe, Edmund; Dawson, Ian; Dawson, John; Daya, Rozmin; De, Kaushik; de Asmundis, Riccardo; De Castro, Stefano; De Castro Faria Salgado, Pedro; De Cecco, Sandro; de Graat, Julien; De Groot, Nicolo; de Jong, Paul; De La Taille, Christophe; De la Torre, Hector; De Lotto, Barbara; de Mora, Lee; De Nooij, Lucie; De Pedis, Daniele; De Salvo, Alessandro; De Sanctis, Umberto; De Santo, Antonella; De Vivie De Regie, Jean-Baptiste; Dean, Simon; Dearnaley, William James; Debbe, Ramiro; Debenedetti, Chiara; Dedovich, Dmitri; Degenhardt, James; Dehchar, Mohamed; Del Papa, Carlo; Del Peso, Jose; Del Prete, Tarcisio; Delemontex, Thomas; Deliyergiyev, Maksym; Dell'Acqua, Andrea; Dell'Asta, Lidia; Della Pietra, Massimo; della Volpe, Domenico; Delmastro, Marco; Delruelle, Nicolas; Delsart, Pierre-Antoine; Deluca, Carolina; Demers, Sarah; Demichev, Mikhail; Demirkoz, Bilge; Deng, Jianrong; Denisov, Sergey; Derendarz, Dominik; Derkaoui, Jamal Eddine; Derue, Frederic; Dervan, Paul; Desch, Klaus Kurt; Devetak, Erik; Deviveiros, Pier-Olivier; Dewhurst, Alastair; DeWilde, Burton; Dhaliwal, Saminder; Dhullipudi, Ramasudhakar; Di Ciaccio, Anna; Di Ciaccio, Lucia; Di Girolamo, Alessandro; Di Girolamo, Beniamino; Di Luise, Silvestro; Di Mattia, Alessandro; Di Micco, Biagio; Di Nardo, Roberto; Di Simone, Andrea; Di Sipio, Riccardo; Diaz, Marco Aurelio; Diblen, Faruk; Diehl, Edward; Dietrich, Janet; Dietzsch, Thorsten; Diglio, Sara; Dindar Yagci, Kamile; Dingfelder, Jochen; Dionisi, Carlo; Dita, Petre; Dita, Sanda; Dittus, Fridolin; Djama, Fares; Djobava, Tamar; Barros do Vale, Maria Aline; Do Valle Wemans, André; Doan, Thi Kieu Oanh; Dobbs, Matt; Dobinson, Robert; Dobos, Daniel; Dobson, Ellie; Dobson, Marc; Dodd, Jeremy; Doglioni, Caterina; Doherty, Tom; Doi, Yoshikuni; Dolejsi, Jiri; Dolenc, Irena; Dolezal, Zdenek; Dolgoshein, Boris; Dohmae, Takeshi; Donadelli, Marisilvia; Donega, Mauro; Donini, Julien; Dopke, Jens; Doria, Alessandra; Dos Anjos, Andre; Dosil, Mireia; Dotti, Andrea; Dova, Maria-Teresa; Dowell, John; Doxiadis, Alexander; Doyle, Tony; Drasal, Zbynek; Drees, Jürgen; Dressnandt, Nandor; Drevermann, Hans; Driouichi, Chafik; Dris, Manolis; Dubbert, Jörg; Dube, Sourabh; Duchovni, Ehud; Duckeck, Guenter; Dudarev, Alexey; Dudziak, Fanny; Dührssen, Michael; Duerdoth, Ian; Duflot, Laurent; Dufour, Marc-Andre; Dunford, Monica; Duran Yildiz, Hatice; Duxfield, Robert; Dwuznik, Michal; Dydak, Friedrich; Düren, Michael; Ebenstein, William; Ebke, Johannes; Eckweiler, Sebastian; Edmonds, Keith; Edwards, Clive; Edwards, Nicholas Charles; Ehrenfeld, Wolfgang; Ehrich, Thies; Eifert, Till; Eigen, Gerald; Einsweiler, Kevin; Eisenhandler, Eric; Ekelof, Tord; El Kacimi, Mohamed; Ellert, Mattias; Elles, Sabine; Ellinghaus, Frank; Ellis, Katherine; Ellis, Nicolas; Elmsheuser, Johannes; Elsing, Markus; Emeliyanov, Dmitry; Engelmann, Roderich; Engl, Albert; Epp, Brigitte; Eppig, Andrew; Erdmann, Johannes; Ereditato, Antonio; Eriksson, Daniel; Ernst, Jesse; Ernst, Michael; Ernwein, Jean; Errede, Deborah; Errede, Steven; Ertel, Eugen; Escalier, Marc; Escobar, Carlos; Espinal Curull, Xavier; Esposito, Bellisario; Etienne, Francois; Etienvre, Anne-Isabelle; Etzion, Erez; Evangelakou, Despoina; Evans, Hal; Fabbri, Laura; Fabre, Caroline; Fakhrutdinov, Rinat; Falciano, Speranza; Fang, Yaquan; Fanti, Marcello; Farbin, Amir; Farilla, Addolorata; Farley, Jason; Farooque, Trisha; Farrington, Sinead; Farthouat, Philippe; Fassnacht, Patrick; Fassouliotis, Dimitrios; Fatholahzadeh, Baharak; Favareto, Andrea; Fayard, Louis; Fazio, Salvatore; Febbraro, Renato; Federic, Pavol; Fedin, Oleg; Fedorko, Woiciech; Fehling-Kaschek, Mirjam; Feligioni, Lorenzo; Fellmann, Denis; Feng, Cunfeng; Feng, Eric; Fenyuk, Alexander; Ferencei, Jozef; Ferland, Jonathan; Fernando, Waruna; Ferrag, Samir; Ferrando, James; Ferrara, Valentina; Ferrari, Arnaud; Ferrari, Pamela; Ferrari, Roberto; Ferreira de Lima, Danilo Enoque; Ferrer, Antonio; Ferrer, Maria Lorenza; Ferrere, Didier; Ferretti, Claudio; Ferretto Parodi, Andrea; Fiascaris, Maria; Fiedler, Frank; Filipčič, Andrej; Filippas, Anastasios; Filthaut, Frank; Fincke-Keeler, Margret; Fiolhais, Miguel; Fiorini, Luca; Firan, Ana; Fischer, Gordon; Fischer, Peter; Fisher, Matthew; Flechl, Martin; Fleck, Ivor; Fleckner, Johanna; Fleischmann, Philipp; Fleischmann, Sebastian; Flick, Tobias; Floderus, Anders; Flores Castillo, Luis; Flowerdew, Michael; Fokitis, Manolis; Fonseca Martin, Teresa; Forbush, David Alan; Formica, Andrea; Forti, Alessandra; Fortin, Dominique; Foster, Joe; Fournier, Daniel; Foussat, Arnaud; Fowler, Andrew; Fowler, Ken; Fox, Harald; Francavilla, Paolo; Franchino, Silvia; Francis, David; Frank, Tal; Franklin, Melissa; Franz, Sebastien; Fraternali, Marco; Fratina, Sasa; French, Sky; Friedrich, Felix; Froeschl, Robert; Froidevaux, Daniel; Frost, James; Fukunaga, Chikara; Fullana Torregrosa, Esteban; Fuster, Juan; Gabaldon, Carolina; Gabizon, Ofir; Gadfort, Thomas; Gadomski, Szymon; Gagliardi, Guido; Gagnon, Pauline; Galea, Cristina; Gallas, Elizabeth; Gallo, Valentina Santina; Gallop, Bruce; Gallus, Petr; Gan, KK; Gao, Yongsheng; Gapienko, Vladimir; Gaponenko, Andrei; Garberson, Ford; Garcia-Sciveres, Maurice; García, Carmen; García Navarro, José Enrique; Gardner, Robert; Garelli, Nicoletta; Garitaonandia, Hegoi; Garonne, Vincent; Garvey, John; Gatti, Claudio; Gaudio, Gabriella; Gaur, Bakul; Gauthier, Lea; Gavrilenko, Igor; Gay, Colin; Gaycken, Goetz; Gayde, Jean-Christophe; Gazis, Evangelos; Ge, Peng; Gee, Norman; Geerts, Daniël Alphonsus Adrianus; Geich-Gimbel, Christoph; Gellerstedt, Karl; Gemme, Claudia; Gemmell, Alistair; Genest, Marie-Hélène; Gentile, Simonetta; George, Matthias; George, Simon; Gerlach, Peter; Gershon, Avi; Geweniger, Christoph; Ghazlane, Hamid; Ghodbane, Nabil; Giacobbe, Benedetto; Giagu, Stefano; Giakoumopoulou, Victoria; Giangiobbe, Vincent; Gianotti, Fabiola; Gibbard, Bruce; Gibson, Adam; Gibson, Stephen; Gilbert, Laura; Gilewsky, Valentin; Gillberg, Dag; Gillman, Tony; Gingrich, Douglas; Ginzburg, Jonatan; Giokaris, Nikos; Giordani, MarioPaolo; Giordano, Raffaele; Giorgi, Francesco Michelangelo; Giovannini, Paola; Giraud, Pierre-Francois; Giugni, Danilo; Giunta, Michele; Giusti, Paolo; Gjelsten, Børge Kile; Gladilin, Leonid; Glasman, Claudia; Glatzer, Julian; Glazov, Alexandre; Glitza, Karl-Walter; Glonti, George; Goddard, Jack Robert; Godfrey, Jennifer; Godlewski, Jan; Goebel, Martin; Göpfert, Thomas; Goeringer, Christian; Gössling, Claus; Göttfert, Tobias; Goldfarb, Steven; Golling, Tobias; Gomes, Agostinho; Gomez Fajardo, Luz Stella; Gonçalo, Ricardo; Goncalves Pinto Firmino Da Costa, Joao; Gonella, Laura; Gonidec, Allain; Gonzalez, Saul; González de la Hoz, Santiago; Gonzalez Parra, Garoe; Gonzalez Silva, Laura; Gonzalez-Sevilla, Sergio; Goodson, Jeremiah Jet; Goossens, Luc; Gorbounov, Petr Andreevich; Gordon, Howard; Gorelov, Igor; Gorfine, Grant; Gorini, Benedetto; Gorini, Edoardo; Gorišek, Andrej; Gornicki, Edward; Gorokhov, Serguei; Goryachev, Vladimir; Gosdzik, Bjoern; Gosselink, Martijn; Gostkin, Mikhail Ivanovitch; Gough Eschrich, Ivo; Gouighri, Mohamed; Goujdami, Driss; Goulette, Marc Phillippe; Goussiou, Anna; Goy, Corinne; Gozpinar, Serdar; Grabowska-Bold, Iwona; Grafström, Per; Grahn, Karl-Johan; Grancagnolo, Francesco; Grancagnolo, Sergio; Grassi, Valerio; Gratchev, Vadim; Grau, Nathan; Gray, Heather; Gray, Julia Ann; Graziani, Enrico; Grebenyuk, Oleg; Greenshaw, Timothy; Greenwood, Zeno Dixon; Gregersen, Kristian; Gregor, Ingrid-Maria; Grenier, Philippe; Griffiths, Justin; Grigalashvili, Nugzar; Grillo, Alexander; Grinstein, Sebastian; Grishkevich, Yaroslav; Grivaz, Jean-Francois; Groh, Manfred; Gross, Eilam; Grosse-Knetter, Joern; Groth-Jensen, Jacob; Grybel, Kai; Guarino, Victor; Guest, Daniel; Guicheney, Christophe; Guida, Angelo; Guindon, Stefan; Guler, Hulya; Gunther, Jaroslav; Guo, Bin; Guo, Jun; Gupta, Ambreesh; Gusakov, Yury; Gushchin, Vladimir; Gutierrez, Phillip; Guttman, Nir; Gutzwiller, Olivier; Guyot, Claude; Gwenlan, Claire; Gwilliam, Carl; Haas, Andy; Haas, Stefan; Haber, Carl; Hackenburg, Robert; Hadavand, Haleh Khani; Hadley, David; Haefner, Petra; Hahn, Ferdinand; Haider, Stefan; Hajduk, Zbigniew; Hakobyan, Hrachya; Hall, David; Haller, Johannes; Hamacher, Klaus; Hamal, Petr; Hamer, Matthias; Hamilton, Andrew; Hamilton, Samuel; Han, Hongguang; Han, Liang; Hanagaki, Kazunori; Hanawa, Keita; Hance, Michael; Handel, Carsten; Hanke, Paul; Hansen, John Renner; Hansen, Jørgen Beck; Hansen, Jorn Dines; Hansen, Peter Henrik; Hansson, Per; Hara, Kazuhiko; Hare, Gabriel; Harenberg, Torsten; Harkusha, Siarhei; Harper, Devin; Harrington, Robert; Harris, Orin; Harrison, Karl; Hartert, Jochen; Hartjes, Fred; Haruyama, Tomiyoshi; Harvey, Alex; Hasegawa, Satoshi; Hasegawa, Yoji; Hassani, Samira; Hatch, Mark; Hauff, Dieter; Haug, Sigve; Hauschild, Michael; Hauser, Reiner; Havranek, Miroslav; Hawes, Brian; Hawkes, Christopher; Hawkings, Richard John; Hawkins, Anthony David; Hawkins, Donovan; Hayakawa, Takashi; Hayashi, Takayasu; Hayden, Daniel; Hayward, Helen; Haywood, Stephen; Hazen, Eric; He, Mao; Head, Simon; Hedberg, Vincent; Heelan, Louise; Heim, Sarah; Heinemann, Beate; Heisterkamp, Simon; Helary, Louis; Heller, Claudio; Heller, Matthieu; Hellman, Sten; Hellmich, Dennis; Helsens, Clement; Henderson, Robert; Henke, Michael; Henrichs, Anna; Henriques Correia, Ana Maria; Henrot-Versille, Sophie; Henry-Couannier, Frédéric; Hensel, Carsten; Henß, Tobias; Medina Hernandez, Carlos; Hernández Jiménez, Yesenia; Herrberg, Ruth; Hershenhorn, Alon David; Herten, Gregor; Hertenberger, Ralf; Hervas, Luis; Hesketh, Gavin Grant; Hessey, Nigel; Higón-Rodriguez, Emilio; Hill, Daniel; Hill, John; Hill, Norman; Hiller, Karl Heinz; Hillert, Sonja; Hillier, Stephen; Hinchliffe, Ian; Hines, Elizabeth; Hirose, Minoru; Hirsch, Florian; Hirschbuehl, Dominic; Hobbs, John; Hod, Noam; Hodgkinson, Mark; Hodgson, Paul; Hoecker, Andreas; Hoeferkamp, Martin; Hoffman, Julia; Hoffmann, Dirk; Hohlfeld, Marc; Holder, Martin; Holmgren, Sven-Olof; Holy, Tomas; Holzbauer, Jenny; Homma, Yasuhiro; Hong, Tae Min; Hooft van Huysduynen, Loek; Horazdovsky, Tomas; Horn, Claus; Horner, Stephan; Hostachy, Jean-Yves; Hou, Suen; Houlden, Michael; Hoummada, Abdeslam; Howarth, James; Howell, David; Hristova, Ivana; Hrivnac, Julius; Hruska, Ivan; Hryn'ova, Tetiana; Hsu, Pai-hsien Jennifer; Hsu, Shih-Chieh; Huang, Guang Shun; Hubacek, Zdenek; Hubaut, Fabrice; Huegging, Fabian; Huettmann, Antje; Huffman, Todd Brian; Hughes, Emlyn; Hughes, Gareth; Hughes-Jones, Richard; Huhtinen, Mika; Hurst, Peter; Hurwitz, Martina; Husemann, Ulrich; Huseynov, Nazim; Huston, Joey; Huth, John; Iacobucci, Giuseppe; Iakovidis, Georgios; Ibbotson, Michael; Ibragimov, Iskander; Ichimiya, Ryo; Iconomidou-Fayard, Lydia; Idarraga, John; Iengo, Paolo; Igonkina, Olga; Ikegami, Yoichi; Ikeno, Masahiro; Ilchenko, Yuri; Iliadis, Dimitrios; Ilic, Nikolina; Imori, Masatoshi; Ince, Tayfun; Inigo-Golfin, Joaquin; Ioannou, Pavlos; Iodice, Mauro; Ippolito, Valerio; Irles Quiles, Adrian; Isaksson, Charlie; Ishikawa, Akimasa; Ishino, Masaya; Ishmukhametov, Renat; Issever, Cigdem; Istin, Serhat; Ivashin, Anton; Iwanski, Wieslaw; Iwasaki, Hiroyuki; Izen, Joseph; Izzo, Vincenzo; Jackson, Brett; Jackson, John; Jackson, Paul; Jaekel, Martin; Jain, Vivek; Jakobs, Karl; Jakobsen, Sune; Jakubek, Jan; Jana, Dilip; Jankowski, Ernest; Jansen, Eric; Jansen, Hendrik; Jantsch, Andreas; Janus, Michel; Jarlskog, Göran; Jeanty, Laura; Jelen, Kazimierz; Jen-La Plante, Imai; Jenni, Peter; Jeremie, Andrea; Jež, Pavel; Jézéquel, Stéphane; Jha, Manoj Kumar; Ji, Haoshuang; Ji, Weina; Jia, Jiangyong; Jiang, Yi; Jimenez Belenguer, Marcos; Jin, Ge; Jin, Shan; Jinnouchi, Osamu; Joergensen, Morten Dam; Joffe, David; Johansen, Lars; Johansen, Marianne; Johansson, Erik; Johansson, Per; Johnert, Sebastian; Johns, Kenneth; Jon-And, Kerstin; Jones, Graham; Jones, Roger; Jones, Tegid; Jones, Tim; Jonsson, Ove; Joram, Christian; Jorge, Pedro; Joseph, John; Jovicevic, Jelena; Jovin, Tatjana; Ju, Xiangyang; Jung, Christian; Jungst, Ralph Markus; Juranek, Vojtech; Jussel, Patrick; Juste Rozas, Aurelio; Kabachenko, Vasily; Kabana, Sonja; Kaci, Mohammed; Kaczmarska, Anna; Kadlecik, Peter; Kado, Marumi; Kagan, Harris; Kagan, Michael; Kaiser, Steffen; Kajomovitz, Enrique; Kalinin, Sergey; Kalinovskaya, Lidia; Kama, Sami; Kanaya, Naoko; Kaneda, Michiru; Kaneti, Steven; Kanno, Takayuki; Kantserov, Vadim; Kanzaki, Junichi; Kaplan, Benjamin; Kapliy, Anton; Kaplon, Jan; Kar, Deepak; Karagoz, Muge; Karnevskiy, Mikhail; Karr, Kristo; Kartvelishvili, Vakhtang; Karyukhin, Andrey; Kashif, Lashkar; Kasieczka, Gregor; Kasmi, Azzedine; Kass, Richard; Kastanas, Alex; Kataoka, Mayuko; Kataoka, Yousuke; Katsoufis, Elias; Katzy, Judith; Kaushik, Venkatesh; Kawagoe, Kiyotomo; Kawamoto, Tatsuo; Kawamura, Gen; Kayl, Manuel; Kazanin, Vassili; Kazarinov, Makhail; Keeler, Richard; Kehoe, Robert; Keil, Markus; Kekelidze, George; Kennedy, John; Kenney, Christopher John; Kenyon, Mike; Kepka, Oldrich; Kerschen, Nicolas; Kerševan, Borut Paul; Kersten, Susanne; Kessoku, Kohei; Keung, Justin; Khakzad, Mohsen; Khalil-zada, Farkhad; Khandanyan, Hovhannes; Khanov, Alexander; Kharchenko, Dmitri; Khodinov, Alexander; Kholodenko, Anatoli; Khomich, Andrei; Khoo, Teng Jian; Khoriauli, Gia; Khoroshilov, Andrey; Khovanskiy, Nikolai; Khovanskiy, Valery; Khramov, Evgeniy; Khubua, Jemal; Kim, Hyeon Jin; Kim, Min Suk; Kim, Shinhong; Kimura, Naoki; Kind, Oliver; King, Barry; King, Matthew; King, Robert Steven Beaufoy; Kirk, Julie; Kirsch, Lawrence; Kiryunin, Andrey; Kishimoto, Tomoe; Kisielewska, Danuta; Kittelmann, Thomas; Kiver, Andrey; Kladiva, Eduard; Klaiber-Lodewigs, Jonas; Klein, Max; Klein, Uta; Kleinknecht, Konrad; Klemetti, Miika; Klier, Amit; Klimek, Pawel; Klimentov, Alexei; Klingenberg, Reiner; Klinger, Joel Alexander; Klinkby, Esben; Klioutchnikova, Tatiana; Klok, Peter; Klous, Sander; Kluge, Eike-Erik; Kluge, Thomas; Kluit, Peter; Kluth, Stefan; Knecht, Neil; Kneringer, Emmerich; Knobloch, Juergen; Knoops, Edith; Knue, Andrea; Ko, Byeong Rok; Kobayashi, Tomio; Kobel, Michael; Kocian, Martin; Kodys, Peter; Köneke, Karsten; König, Adriaan; Koenig, Sebastian; Köpke, Lutz; Koetsveld, Folkert; Koevesarki, Peter; Koffas, Thomas; Koffeman, Els; Kogan, Lucy Anne; Kohn, Fabian; Kohout, Zdenek; Kohriki, Takashi; Koi, Tatsumi; Kokott, Thomas; Kolachev, Guennady; Kolanoski, Hermann; Kolesnikov, Vladimir; Koletsou, Iro; Koll, James; Kollefrath, Michael; Kolya, Scott; Komar, Aston; Komori, Yuto; Kondo, Takahiko; Kono, Takanori; Kononov, Anatoly; Konoplich, Rostislav; Konstantinidis, Nikolaos; Kootz, Andreas; Koperny, Stefan; Korcyl, Krzysztof; Kordas, Kostantinos; Koreshev, Victor; Korn, Andreas; Korol, Aleksandr; Korolkov, Ilya; Korolkova, Elena; Korotkov, Vladislav; Kortner, Oliver; Kortner, Sandra; Kostyukhin, Vadim; Kotamäki, Miikka Juhani; Kotov, Sergey; Kotov, Vladislav; Kotwal, Ashutosh; Kourkoumelis, Christine; Kouskoura, Vasiliki; Koutsman, Alex; Kowalewski, Robert Victor; Kowalski, Tadeusz; Kozanecki, Witold; Kozhin, Anatoly; Kral, Vlastimil; Kramarenko, Viktor; Kramberger, Gregor; Krasny, Mieczyslaw Witold; Krasznahorkay, Attila; Kraus, James; Kraus, Jana; Kreisel, Arik; Krejci, Frantisek; Kretzschmar, Jan; Krieger, Nina; Krieger, Peter; Kroeninger, Kevin; Kroha, Hubert; Kroll, Joe; Kroseberg, Juergen; Krstic, Jelena; Kruchonak, Uladzimir; Krüger, Hans; Kruker, Tobias; Krumnack, Nils; Krumshteyn, Zinovii; Kruth, Andre; Kubota, Takashi; Kuday, Sinan; Kuehn, Susanne; Kugel, Andreas; Kuhl, Thorsten; Kuhn, Dietmar; Kukhtin, Victor; Kulchitsky, Yuri; Kuleshov, Sergey; Kummer, Christian; Kuna, Marine; Kundu, Nikhil; Kunkle, Joshua; Kupco, Alexander; Kurashige, Hisaya; Kurata, Masakazu; Kurochkin, Yurii; Kus, Vlastimil; Kuwertz, Emma Sian; Kuze, Masahiro; Kvita, Jiri; Kwee, Regina; La Rosa, Alessandro; La Rotonda, Laura; Labarga, Luis; Labbe, Julien; Lablak, Said; Lacasta, Carlos; Lacava, Francesco; Lacker, Heiko; Lacour, Didier; Lacuesta, Vicente Ramón; Ladygin, Evgueni; Lafaye, Remi; Laforge, Bertrand; Lagouri, Theodota; Lai, Stanley; Laisne, Emmanuel; Lamanna, Massimo; Lampen, Caleb; Lampl, Walter; Lancon, Eric; Landgraf, Ulrich; Landon, Murrough; Lane, Jenna; Lange, Clemens; Lankford, Andrew; Lanni, Francesco; Lantzsch, Kerstin; Laplace, Sandrine; Lapoire, Cecile; Laporte, Jean-Francois; Lari, Tommaso; Larionov, Anatoly; Larner, Aimee; Lasseur, Christian; Lassnig, Mario; Laurelli, Paolo; Lavorini, Vincenzo; Lavrijsen, Wim; Laycock, Paul; Lazarev, Alexandre; Le Dortz, Olivier; Le Guirriec, Emmanuel; Le Maner, Christophe; Le Menedeu, Eve; Lebel, Céline; LeCompte, Thomas; Ledroit-Guillon, Fabienne Agnes Marie; Lee, Hurng-Chun; Lee, Jason; Lee, Shih-Chang; Lee, Lawrence; Lefebvre, Michel; Legendre, Marie; Leger, Annie; LeGeyt, Benjamin; Legger, Federica; Leggett, Charles; Lehmacher, Marc; Lehmann Miotto, Giovanna; Lei, Xiaowen; Leite, Marco Aurelio Lisboa; Leitner, Rupert; Lellouch, Daniel; Leltchouk, Mikhail; Lemmer, Boris; Lendermann, Victor; Leney, Katharine; Lenz, Tatiana; Lenzen, Georg; Lenzi, Bruno; Leonhardt, Kathrin; Leontsinis, Stefanos; Leroy, Claude; Lessard, Jean-Raphael; Lesser, Jonas; Lester, Christopher; Leung Fook Cheong, Annabelle; Levêque, Jessica; Levin, Daniel; Levinson, Lorne; Levitski, Mikhail; Lewis, Adrian; Lewis, George; Leyko, Agnieszka; Leyton, Michael; Li, Bo; Li, Haifeng; Li, Shu; Li, Xuefei; Liang, Zhijun; Liao, Hongbo; Liberti, Barbara; Lichard, Peter; Lichtnecker, Markus; Lie, Ki; Liebig, Wolfgang; Lifshitz, Ronen; Lilley, Joseph; Limbach, Christian; Limosani, Antonio; Limper, Maaike; Lin, Simon; Linde, Frank; Linnemann, James; Lipeles, Elliot; Lipinsky, Lukas; Lipniacka, Anna; Liss, Tony; Lissauer, David; Lister, Alison; Litke, Alan; Liu, Chuanlei; Liu, Dong; Liu, Hao; Liu, Jianbei; Liu, Minghui; Liu, Yanwen; Livan, Michele; Livermore, Sarah; Lleres, Annick; Llorente Merino, Javier; Lloyd, Stephen; Lobodzinska, Ewelina; Loch, Peter; Lockman, William; Loddenkoetter, Thomas; Loebinger, Fred; Loginov, Andrey; Loh, Chang Wei; Lohse, Thomas; Lohwasser, Kristin; Lokajicek, Milos; Loken, James; Lombardo, Vincenzo Paolo; Long, Robin Eamonn; Lopes, Lourenco; Lopez Mateos, David; Lorenz, Jeanette; Lorenzo Martinez, Narei; Losada, Marta; Loscutoff, Peter; Lo Sterzo, Francesco; Losty, Michael; Lou, Xinchou; Lounis, Abdenour; Loureiro, Karina; Love, Jeremy; Love, Peter; Lowe, Andrew; Lu, Feng; Lubatti, Henry; Luci, Claudio; Lucotte, Arnaud; Ludwig, Andreas; Ludwig, Dörthe; Ludwig, Inga; Ludwig, Jens; Luehring, Frederick; Luijckx, Guy; Lumb, Debra; Luminari, Lamberto; Lund, Esben; Lund-Jensen, Bengt; Lundberg, Björn; Lundberg, Johan; Lundquist, Johan; Lungwitz, Matthias; Lutz, Gerhard; Lynn, David; Lys, Jeremy; Lytken, Else; Ma, Hong; Ma, Lian Liang; Macana Goia, Jorge Andres; Maccarrone, Giovanni; Macchiolo, Anna; Maček, Boštjan; Machado Miguens, Joana; Mackeprang, Rasmus; Madaras, Ronald; Mader, Wolfgang; Maenner, Reinhard; Maeno, Tadashi; Mättig, Peter; Mättig, Stefan; Magnoni, Luca; Magradze, Erekle; Mahalalel, Yair; Mahboubi, Kambiz; Mahout, Gilles; Maiani, Camilla; Maidantchik, Carmen; Maio, Amélia; Majewski, Stephanie; Makida, Yasuhiro; Makovec, Nikola; Mal, Prolay; Malaescu, Bogdan; Malecki, Pawel; Malecki, Piotr; Maleev, Victor; Malek, Fairouz; Mallik, Usha; Malon, David; Malone, Caitlin; Maltezos, Stavros; Malyshev, Vladimir; Malyukov, Sergei; Mameghani, Raphael; Mamuzic, Judita; Manabe, Atsushi; Mandelli, Luciano; Mandić, Igor; Mandrysch, Rocco; Maneira, José; Mangeard, Pierre-Simon; Manhaes de Andrade Filho, Luciano; Manjavidze, Ioseb; Mann, Alexander; Manning, Peter; Manousakis-Katsikakis, Arkadios; Mansoulie, Bruno; Manz, Andreas; Mapelli, Alessandro; Mapelli, Livio; March, Luis; Marchand, Jean-Francois; Marchese, Fabrizio; Marchiori, Giovanni; Marcisovsky, Michal; Marin, Alexandru; Marino, Christopher; Marroquim, Fernando; Marshall, Robin; Marshall, Zach; Martens, Kalen; Marti-Garcia, Salvador; Martin, Andrew; Martin, Brian; Martin, Brian Thomas; Martin, Franck Francois; Martin, Jean-Pierre; Martin, Philippe; Martin, Tim; Martin, Victoria Jane; Martin dit Latour, Bertrand; Martin-Haugh, Stewart; Martinez, Mario; Martinez Outschoorn, Verena; Martyniuk, Alex; Marx, Marilyn; Marzano, Francesco; Marzin, Antoine; Masetti, Lucia; Mashimo, Tetsuro; Mashinistov, Ruslan; Masik, Jiri; Maslennikov, Alexey; Massa, Ignazio; Massaro, Graziano; Massol, Nicolas; Mastrandrea, Paolo; Mastroberardino, Anna; Masubuchi, Tatsuya; Mathes, Markus; Matricon, Pierre; Matsumoto, Hiroshi; Matsunaga, Hiroyuki; Matsushita, Takashi; Mattravers, Carly; Maugain, Jean-Marie; Maurer, Julien; Maxfield, Stephen; Maximov, Dmitriy; May, Edward; Mayne, Anna; Mazini, Rachid; Mazur, Michael; Mazzanti, Marcello; Mazzoni, Enrico; Mc Kee, Shawn Patrick; McCarn, Allison; McCarthy, Robert; McCarthy, Tom; McCubbin, Norman; McFarlane, Kenneth; Mcfayden, Josh; McGlone, Helen; Mchedlidze, Gvantsa; McLaren, Robert Andrew; Mclaughlan, Tom; McMahon, Steve; McPherson, Robert; Meade, Andrew; Mechnich, Joerg; Mechtel, Markus; Medinnis, Mike; Meera-Lebbai, Razzak; Meguro, Tatsuma; Mehdiyev, Rashid; Mehlhase, Sascha; Mehta, Andrew; Meier, Karlheinz; Meirose, Bernhard; Melachrinos, Constantinos; Mellado Garcia, Bruce Rafael; Mendoza Navas, Luis; Meng, Zhaoxia; Mengarelli, Alberto; Menke, Sven; Menot, Claude; Meoni, Evelin; Mercurio, Kevin Michael; Mermod, Philippe; Merola, Leonardo; Meroni, Chiara; Merritt, Frank; Merritt, Hayes; Messina, Andrea; Metcalfe, Jessica; Mete, Alaettin Serhan; Meyer, Carsten; Meyer, Christopher; Meyer, Jean-Pierre; Meyer, Jochen; Meyer, Joerg; Meyer, Thomas Christian; Meyer, W Thomas; Miao, Jiayuan; Michal, Sebastien; Micu, Liliana; Middleton, Robin; Migas, Sylwia; Mijović, Liza; Mikenberg, Giora; Mikestikova, Marcela; Mikuž, Marko; Miller, David; Miller, Robert; Mills, Bill; Mills, Corrinne; Milov, Alexander; Milstead, David; Milstein, Dmitry; Minaenko, Andrey; Miñano Moya, Mercedes; Minashvili, Irakli; Mincer, Allen; Mindur, Bartosz; Mineev, Mikhail; Ming, Yao; Mir, Lluisa-Maria; Mirabelli, Giovanni; Miralles Verge, Lluis; Misiejuk, Andrzej; Mitrevski, Jovan; Mitrofanov, Gennady; Mitsou, Vasiliki A; Mitsui, Shingo; Miyagawa, Paul; Miyazaki, Kazuki; Mjörnmark, Jan-Ulf; Moa, Torbjoern; Mockett, Paul; Moed, Shulamit; Moeller, Victoria; Mönig, Klaus; Möser, Nicolas; Mohapatra, Soumya; Mohr, Wolfgang; Mohrdieck-Möck, Susanne; Moisseev, Artemy; Moles-Valls, Regina; Molina-Perez, Jorge; Monk, James; Monnier, Emmanuel; Montesano, Simone; Monticelli, Fernando; Monzani, Simone; Moore, Roger; Moorhead, Gareth; Mora Herrera, Clemencia; Moraes, Arthur; Morange, Nicolas; Morel, Julien; Morello, Gianfranco; Moreno, Deywis; Moreno Llácer, María; Morettini, Paolo; Morgenstern, Marcus; Morii, Masahiro; Morin, Jerome; Morley, Anthony Keith; Mornacchi, Giuseppe; Morozov, Sergey; Morris, John; Morvaj, Ljiljana; Moser, Hans-Guenther; Mosidze, Maia; Moss, Josh; Mount, Richard; Mountricha, Eleni; Mouraviev, Sergei; Moyse, Edward; Mudrinic, Mihajlo; Mueller, Felix; Mueller, James; Mueller, Klemens; Müller, Thomas; Mueller, Timo; Muenstermann, Daniel; Muir, Alex; Munwes, Yonathan; Murray, Bill; Mussche, Ido; Musto, Elisa; Myagkov, Alexey; Nadal, Jordi; Nagai, Koichi; Nagano, Kunihiro; Nagarkar, Advait; Nagasaka, Yasushi; Nagel, Martin; Nairz, Armin Michael; Nakahama, Yu; Nakamura, Koji; Nakamura, Tomoaki; Nakano, Itsuo; Nanava, Gizo; Napier, Austin; Narayan, Rohin; Nash, Michael; Nation, Nigel; Nattermann, Till; Naumann, Thomas; Navarro, Gabriela; Neal, Homer; Nebot, Eduardo; Nechaeva, Polina; Neep, Thomas James; Negri, Andrea; Negri, Guido; Nektarijevic, Snezana; Nelson, Andrew; Nelson, Silke; Nelson, Timothy Knight; Nemecek, Stanislav; Nemethy, Peter; Nepomuceno, Andre Asevedo; Nessi, Marzio; Neubauer, Mark; Neusiedl, Andrea; Neves, Ricardo; Nevski, Pavel; Newman, Paul; Nguyen Thi Hong, Van; Nickerson, Richard; Nicolaidou, Rosy; Nicolas, Ludovic; Nicquevert, Bertrand; Niedercorn, Francois; Nielsen, Jason; Niinikoski, Tapio; Nikiforou, Nikiforos; Nikiforov, Andriy; Nikolaenko, Vladimir; Nikolaev, Kirill; Nikolic-Audit, Irena; Nikolics, Katalin; Nikolopoulos, Konstantinos; Nilsen, Henrik; Nilsson, Paul; Ninomiya, Yoichi; Nisati, Aleandro; Nishiyama, Tomonori; Nisius, Richard; Nodulman, Lawrence; Nomachi, Masaharu; Nomidis, Ioannis; Nordberg, Markus; Nordkvist, Bjoern; Norton, Peter; Novakova, Jana; Nozaki, Mitsuaki; Nozka, Libor; Nugent, Ian Michael; Nuncio-Quiroz, Adriana-Elizabeth; Nunes Hanninger, Guilherme; Nunnemann, Thomas; Nurse, Emily; O'Brien, Brendan Joseph; O'Neale, Steve; O'Neil, Dugan; O'Shea, Val; Oakes, Louise Beth; Oakham, Gerald; Oberlack, Horst; Ocariz, Jose; Ochi, Atsuhiko; Oda, Susumu; Odaka, Shigeru; Odier, Jerome; Ogren, Harold; Oh, Alexander; Oh, Seog; Ohm, Christian; Ohshima, Takayoshi; Ohshita, Hidetoshi; Ohsugi, Takashi; Okada, Shogo; Okawa, Hideki; Okumura, Yasuyuki; Okuyama, Toyonobu; Olariu, Albert; Olcese, Marco; Olchevski, Alexander; Olivares Pino, Sebastian Andres; Oliveira, Miguel Alfonso; Oliveira Damazio, Denis; Oliver Garcia, Elena; Olivito, Dominick; Olszewski, Andrzej; Olszowska, Jolanta; Omachi, Chihiro; Onofre, António; Onyisi, Peter; Oram, Christopher; Oreglia, Mark; Oren, Yona; Orestano, Domizia; Orlov, Iliya; Oropeza Barrera, Cristina; Orr, Robert; Osculati, Bianca; Ospanov, Rustem; Osuna, Carlos; Otero y Garzon, Gustavo; Ottersbach, John; Ouchrif, Mohamed; Ouellette, Eric; Ould-Saada, Farid; Ouraou, Ahmimed; Ouyang, Qun; Ovcharova, Ana; Owen, Mark; Owen, Simon; Ozcan, Veysi Erkcan; Ozturk, Nurcan; Pacheco Pages, Andres; Padilla Aranda, Cristobal; Pagan Griso, Simone; Paganis, Efstathios; Paige, Frank; Pais, Preema; Pajchel, Katarina; Palacino, Gabriel; Paleari, Chiara; Palestini, Sandro; Pallin, Dominique; Palma, Alberto; Palmer, Jody; Pan, Yibin; Panagiotopoulou, Evgenia; Panes, Boris; Panikashvili, Natalia; Panitkin, Sergey; Pantea, Dan; Panuskova, Monika; Paolone, Vittorio; Papadelis, Aras; Papadopoulou, Theodora; Paramonov, Alexander; Park, Woochun; Parker, Andy; Parodi, Fabrizio; Parsons, John; Parzefall, Ulrich; Pasqualucci, Enrico; Passaggio, Stefano; Passeri, Antonio; Pastore, Fernanda; Pastore, Francesca; Pásztor, Gabriella; Pataraia, Sophio; Patel, Nikhul; Pater, Joleen; Patricelli, Sergio; Pauly, Thilo; Pecsy, Martin; Pedraza Morales, Maria Isabel; Peleganchuk, Sergey; Peng, Haiping; Pengo, Ruggero; Penning, Bjoern; Penson, Alexander; Penwell, John; Perantoni, Marcelo; Perez, Kerstin; Perez Cavalcanti, Tiago; Perez Codina, Estel; Pérez García-Estañ, María Teresa; Perez Reale, Valeria; Perini, Laura; Pernegger, Heinz; Perrino, Roberto; Perrodo, Pascal; Persembe, Seda; Perus, Antoine; Peshekhonov, Vladimir; Peters, Krisztian; Petersen, Brian; Petersen, Jorgen; Petersen, Troels; Petit, Elisabeth; Petridis, Andreas; Petridou, Chariclia; Petrolo, Emilio; Petrucci, Fabrizio; Petschull, Dennis; Petteni, Michele; Pezoa, Raquel; Phan, Anna; Phillips, Peter William; Piacquadio, Giacinto; Piccaro, Elisa; Piccinini, Maurizio; Piec, Sebastian Marcin; Piegaia, Ricardo; Pignotti, David; Pilcher, James; Pilkington, Andrew; Pina, João Antonio; Pinamonti, Michele; Pinder, Alex; Pinfold, James; Ping, Jialun; Pinto, Belmiro; Pirotte, Olivier; Pizio, Caterina; Placakyte, Ringaile; Plamondon, Mathieu; Pleier, Marc-Andre; Pleskach, Anatoly; Poblaguev, Andrei; Poddar, Sahill; Podlyski, Fabrice; Poggioli, Luc; Poghosyan, Tatevik; Pohl, Martin; Polci, Francesco; Polesello, Giacomo; Policicchio, Antonio; Polini, Alessandro; Poll, James; Polychronakos, Venetios; Pomarede, Daniel Marc; Pomeroy, Daniel; Pommès, Kathy; Pontecorvo, Ludovico; Pope, Bernard; Popeneciu, Gabriel Alexandru; Popovic, Dragan; Poppleton, Alan; Portell Bueso, Xavier; Posch, Christoph; Pospelov, Guennady; Pospisil, Stanislav; Potrap, Igor; Potter, Christina; Potter, Christopher; Poulard, Gilbert; Poveda, Joaquin; Pozdnyakov, Valery; Prabhu, Robindra; Pralavorio, Pascal; Pranko, Aliaksandr; Prasad, Srivas; Pravahan, Rishiraj; Prell, Soeren; Pretzl, Klaus Peter; Pribyl, Lukas; Price, Darren; Price, Joe; Price, Lawrence; Price, Michael John; Prieur, Damien; Primavera, Margherita; Prokofiev, Kirill; Prokoshin, Fedor; Protopopescu, Serban; Proudfoot, James; Prudent, Xavier; Przybycien, Mariusz; Przysiezniak, Helenka; Psoroulas, Serena; Ptacek, Elizabeth; Pueschel, Elisa; Purdham, John; Purohit, Milind; Puzo, Patrick; Pylypchenko, Yuriy; Qian, Jianming; Qian, Zuxuan; Qin, Zhonghua; Quadt, Arnulf; Quarrie, David; Quayle, William; Quinonez, Fernando; Raas, Marcel; Radescu, Voica; Radics, Balint; Radloff, Peter; Rador, Tonguc; Ragusa, Francesco; Rahal, Ghita; Rahimi, Amir; Rahm, David; Rajagopalan, Srinivasan; Rammensee, Michael; Rammes, Marcus; Randle-Conde, Aidan Sean; Randrianarivony, Koloina; Ratoff, Peter; Rauscher, Felix; Rave, Tobias Christian; Raymond, Michel; Read, Alexander Lincoln; Rebuzzi, Daniela; Redelbach, Andreas; Redlinger, George; Reece, Ryan; Reeves, Kendall; Reichold, Armin; Reinherz-Aronis, Erez; Reinsch, Andreas; Reisinger, Ingo; Rembser, Christoph; Ren, Zhongliang; Renaud, Adrien; Renkel, Peter; Rescigno, Marco; Resconi, Silvia; Resende, Bernardo; Reznicek, Pavel; Rezvani, Reyhaneh; Richards, Alexander; Richter, Robert; Richter-Was, Elzbieta; Ridel, Melissa; Rijpstra, Manouk; Rijssenbeek, Michael; Rimoldi, Adele; Rinaldi, Lorenzo; Rios, Ryan Randy; Riu, Imma; Rivoltella, Giancesare; Rizatdinova, Flera; Rizvi, Eram; Robertson, Steven; Robichaud-Veronneau, Andree; Robinson, Dave; Robinson, James; Robinson, Mary; Robson, Aidan; Rocha de Lima, Jose Guilherme; Roda, Chiara; Roda Dos Santos, Denis; Rodriguez, Diego; Roe, Adam; Roe, Shaun; Røhne, Ole; Rojo, Victoria; Rolli, Simona; Romaniouk, Anatoli; Romano, Marino; Romanov, Victor; Romeo, Gaston; Romero Adam, Elena; Roos, Lydia; Ros, Eduardo; Rosati, Stefano; Rosbach, Kilian; Rose, Anthony; Rose, Matthew; Rosenbaum, Gabriel; Rosenberg, Eli; Rosendahl, Peter Lundgaard; Rosenthal, Oliver; Rosselet, Laurent; Rossetti, Valerio; Rossi, Elvira; Rossi, Leonardo Paolo; Rotaru, Marina; Roth, Itamar; Rothberg, Joseph; Rousseau, David; Royon, Christophe; Rozanov, Alexander; Rozen, Yoram; Ruan, Xifeng; Rubinskiy, Igor; Ruckert, Benjamin; Ruckstuhl, Nicole; Rud, Viacheslav; Rudolph, Christian; Rudolph, Gerald; Rühr, Frederik; Ruggieri, Federico; Ruiz-Martinez, Aranzazu; Rumiantsev, Viktor; Rumyantsev, Leonid; Runge, Kay; Rurikova, Zuzana; Rusakovich, Nikolai; Rust, Dave; Rutherfoord, John; Ruwiedel, Christoph; Ruzicka, Pavel; Ryabov, Yury; Ryadovikov, Vasily; Ryan, Patrick; Rybar, Martin; Rybkin, Grigori; Ryder, Nick; Rzaeva, Sevda; Saavedra, Aldo; Sadeh, Iftach; Sadrozinski, Hartmut; Sadykov, Renat; Safai Tehrani, Francesco; Sakamoto, Hiroshi; Salamanna, Giuseppe; Salamon, Andrea; Saleem, Muhammad; Salihagic, Denis; Salnikov, Andrei; Salt, José; Salvachua Ferrando, Belén; Salvatore, Daniela; Salvatore, Pasquale Fabrizio; Salvucci, Antonio; Salzburger, Andreas; Sampsonidis, Dimitrios; Samset, Björn Hallvard; Sanchez, Arturo; Sanchez Martinez, Victoria; Sandaker, Heidi; Sander, Heinz Georg; Sanders, Michiel; Sandhoff, Marisa; Sandoval, Tanya; Sandoval, Carlos; Sandstroem, Rikard; Sandvoss, Stephan; Sankey, Dave; Sansoni, Andrea; Santamarina Rios, Cibran; Santoni, Claudio; Santonico, Rinaldo; Santos, Helena; Saraiva, João; Sarangi, Tapas; Sarkisyan-Grinbaum, Edward; Sarri, Francesca; Sartisohn, Georg; Sasaki, Osamu; Sasaki, Takashi; Sasao, Noboru; Satsounkevitch, Igor; Sauvage, Gilles; Sauvan, Emmanuel; Sauvan, Jean-Baptiste; Savard, Pierre; Savinov, Vladimir; Savu, Dan Octavian; Sawyer, Lee; Saxon, David; Says, Louis-Pierre; Sbarra, Carla; Sbrizzi, Antonio; Scallon, Olivia; Scannicchio, Diana; Scarcella, Mark; Schaarschmidt, Jana; Schacht, Peter; Schäfer, Uli; Schaepe, Steffen; Schaetzel, Sebastian; Schaffer, Arthur; Schaile, Dorothee; Schamberger, R. Dean; Schamov, Andrey; Scharf, Veit; Schegelsky, Valery; Scheirich, Daniel; Schernau, Michael; Scherzer, Max; Schiavi, Carlo; Schieck, Jochen; Schioppa, Marco; Schlenker, Stefan; Schlereth, James; Schmidt, Evelyn; Schmieden, Kristof; Schmitt, Christian; Schmitt, Sebastian; Schmitz, Martin; Schöning, André; Schott, Matthias; Schouten, Doug; Schovancova, Jaroslava; Schram, Malachi; Schroeder, Christian; Schroer, Nicolai; Schuh, Silvia; Schuler, Georges; Schultens, Martin Johannes; Schultes, Joachim; Schultz-Coulon, Hans-Christian; Schulz, Holger; Schumacher, Jan; Schumacher, Markus; Schumm, Bruce; Schune, Philippe; Schwanenberger, Christian; Schwartzman, Ariel; Schwemling, Philippe; Schwienhorst, Reinhard; Schwierz, Rainer; Schwindling, Jerome; Schwindt, Thomas; Schwoerer, Maud; Scott, Bill; Searcy, Jacob; Sedov, George; Sedykh, Evgeny; Segura, Ester; Seidel, Sally; Seiden, Abraham; Seifert, Frank; Seixas, José; Sekhniaidze, Givi; Selbach, Karoline Elfriede; Seliverstov, Dmitry; Sellden, Bjoern; Sellers, Graham; Seman, Michal; Semprini-Cesari, Nicola; Serfon, Cedric; Serin, Laurent; Serkin, Leonid; Seuster, Rolf; Severini, Horst; Sevior, Martin; Sfyrla, Anna; Shabalina, Elizaveta; Shamim, Mansoora; Shan, Lianyou; Shank, James; Shao, Qi Tao; Shapiro, Marjorie; Shatalov, Pavel; Shaver, Leif; Shaw, Kate; Sherman, Daniel; Sherwood, Peter; Shibata, Akira; Shichi, Hideharu; Shimizu, Shima; Shimojima, Makoto; Shin, Taeksu; Shiyakova, Maria; Shmeleva, Alevtina; Shochet, Mel; Short, Daniel; Shrestha, Suyog; Shulga, Evgeny; Shupe, Michael; Sicho, Petr; Sidoti, Antonio; Siegert, Frank; Sijacki, Djordje; Silbert, Ohad; Silva, José; Silver, Yiftah; Silverstein, Daniel; Silverstein, Samuel; Simak, Vladislav; Simard, Olivier; Simic, Ljiljana; Simion, Stefan; Simmons, Brinick; Simonyan, Margar; Sinervo, Pekka; Sinev, Nikolai; Sipica, Valentin; Siragusa, Giovanni; Sircar, Anirvan; Sisakyan, Alexei; Sivoklokov, Serguei; Sjölin, Jörgen; Sjursen, Therese; Skinnari, Louise Anastasia; Skottowe, Hugh Philip; Skovpen, Kirill; Skubic, Patrick; Skvorodnev, Nikolai; Slater, Mark; Slavicek, Tomas; Sliwa, Krzysztof; Sloper, John erik; Smakhtin, Vladimir; Smart, Ben; Smirnov, Sergei; Smirnov, Yury; Smirnova, Lidia; Smirnova, Oxana; Smith, Ben Campbell; Smith, Douglas; Smith, Kenway; Smizanska, Maria; Smolek, Karel; Snesarev, Andrei; Snow, Steve; Snow, Joel; Snuverink, Jochem; Snyder, Scott; Soares, Mara; Sobie, Randall; Sodomka, Jaromir; Soffer, Abner; Solans, Carlos; Solar, Michael; Solc, Jaroslav; Soldatov, Evgeny; Soldevila, Urmila; Solfaroli Camillocci, Elena; Solodkov, Alexander; Solovyanov, Oleg; Soni, Nitesh; Sopko, Vit; Sopko, Bruno; Sosebee, Mark; Soualah, Rachik; Soukharev, Andrey; Spagnolo, Stefania; Spanò, Francesco; Spighi, Roberto; Spigo, Giancarlo; Spila, Federico; Spiwoks, Ralf; Spousta, Martin; Spreitzer, Teresa; Spurlock, Barry; St Denis, Richard Dante; Stahlman, Jonathan; Stamen, Rainer; Stanecka, Ewa; Stanek, Robert; Stanescu, Cristian; Stapnes, Steinar; Starchenko, Evgeny; Stark, Jan; Staroba, Pavel; Starovoitov, Pavel; Staude, Arnold; Stavina, Pavel; Stavropoulos, Georgios; Steele, Genevieve; Steinbach, Peter; Steinberg, Peter; Stekl, Ivan; Stelzer, Bernd; Stelzer, Harald Joerg; Stelzer-Chilton, Oliver; Stenzel, Hasko; Stern, Sebastian; Stevenson, Kyle; Stewart, Graeme; Stillings, Jan Andre; Stockton, Mark; Stoerig, Kathrin; Stoicea, Gabriel; Stonjek, Stefan; Strachota, Pavel; Stradling, Alden; Straessner, Arno; Strandberg, Jonas; Strandberg, Sara; Strandlie, Are; Strang, Michael; Strauss, Emanuel; Strauss, Michael; Strizenec, Pavol; Ströhmer, Raimund; Strom, David; Strong, John; Stroynowski, Ryszard; Strube, Jan; Stugu, Bjarne; Stumer, Iuliu; Stupak, John; Sturm, Philipp; Styles, Nicholas Adam; Soh, Dart-yin; Su, Dong; Subramania, Halasya Siva; Succurro, Antonella; Sugaya, Yorihito; Sugimoto, Takuya; Suhr, Chad; Suita, Koichi; Suk, Michal; Sulin, Vladimir; Sultansoy, Saleh; Sumida, Toshi; Sun, Xiaohu; Sundermann, Jan Erik; Suruliz, Kerim; Sushkov, Serge; Susinno, Giancarlo; Sutton, Mark; Suzuki, Yu; Suzuki, Yuta; Svatos, Michal; Sviridov, Yuri; Swedish, Stephen; Sykora, Ivan; Sykora, Tomas; Szeless, Balazs; Sánchez, Javier; Ta, Duc; Tackmann, Kerstin; Taffard, Anyes; Tafirout, Reda; Taiblum, Nimrod; Takahashi, Yuta; Takai, Helio; Takashima, Ryuichi; Takeda, Hiroshi; Takeshita, Tohru; Takubo, Yosuke; Talby, Mossadek; Talyshev, Alexey; Tamsett, Matthew; Tanaka, Junichi; Tanaka, Reisaburo; Tanaka, Satoshi; Tanaka, Shuji; Tanaka, Yoshito; Tanasijczuk, Andres Jorge; Tani, Kazutoshi; Tannoury, Nancy; Tappern, Geoffrey; Tapprogge, Stefan; Tardif, Dominique; Tarem, Shlomit; Tarrade, Fabien; Tartarelli, Giuseppe Francesco; Tas, Petr; Tasevsky, Marek; Tassi, Enrico; Tatarkhanov, Mous; Tayalati, Yahya; Taylor, Christopher; Taylor, Frank; Taylor, Geoffrey; Taylor, Wendy; Teinturier, Marthe; Teixeira Dias Castanheira, Matilde; Teixeira-Dias, Pedro; Temming, Kim Katrin; Ten Kate, Herman; Teng, Ping-Kun; Terada, Susumu; Terashi, Koji; Terron, Juan; Testa, Marianna; Teuscher, Richard; Thadome, Jocelyn; Therhaag, Jan; Theveneaux-Pelzer, Timothée; Thioye, Moustapha; Thoma, Sascha; Thomas, Juergen; Thompson, Emily; Thompson, Paul; Thompson, Peter; Thompson, Stan; Thomsen, Lotte Ansgaard; Thomson, Evelyn; Thomson, Mark; Thun, Rudolf; Tian, Feng; Tibbetts, Mark James; Tic, Tomáš; Tikhomirov, Vladimir; Tikhonov, Yury; Timoshenko, Sergey; Tipton, Paul; Tique Aires Viegas, Florbela De Jes; Tisserant, Sylvain; Tobias, Jürgen; Toczek, Barbara; Todorov, Theodore; Todorova-Nova, Sharka; Toggerson, Brokk; Tojo, Junji; Tokár, Stanislav; Tokunaga, Kaoru; Tokushuku, Katsuo; Tollefson, Kirsten; Tomoto, Makoto; Tompkins, Lauren; Toms, Konstantin; Tong, Guoliang; Tonoyan, Arshak; Topfel, Cyril; Topilin, Nikolai; Torchiani, Ingo; Torrence, Eric; Torres, Heberth; Torró Pastor, Emma; Toth, Jozsef; Touchard, Francois; Tovey, Daniel; Trefzger, Thomas; Tremblet, Louis; Tricoli, Alesandro; Trigger, Isabel Marian; Trincaz-Duvoid, Sophie; Trinh, Thi Nguyet; Tripiana, Martin; Trischuk, William; Trivedi, Arjun; Trocmé, Benjamin; Troncon, Clara; Trottier-McDonald, Michel; Trzebinski, Maciej; Trzupek, Adam; Tsarouchas, Charilaos; Tseng, Jeffrey; Tsiakiris, Menelaos; Tsiareshka, Pavel; Tsionou, Dimitra; Tsipolitis, Georgios; Tsiskaridze, Vakhtang; Tskhadadze, Edisher; Tsukerman, Ilya; Tsulaia, Vakhtang; Tsung, Jieh-Wen; Tsuno, Soshi; Tsybychev, Dmitri; Tua, Alan; Tudorache, Alexandra; Tudorache, Valentina; Tuggle, Joseph; Turala, Michal; Turecek, Daniel; Turk Cakir, Ilkay; Turlay, Emmanuel; Turra, Ruggero; Tuts, Michael; Tykhonov, Andrii; Tylmad, Maja; Tyndel, Mike; Tzanakos, George; Uchida, Kirika; Ueda, Ikuo; Ueno, Ryuichi; Ugland, Maren; Uhlenbrock, Mathias; Uhrmacher, Michael; Ukegawa, Fumihiko; Unal, Guillaume; Underwood, David; Undrus, Alexander; Unel, Gokhan; Unno, Yoshinobu; Urbaniec, Dustin; Usai, Giulio; Uslenghi, Massimiliano; Vacavant, Laurent; Vacek, Vaclav; Vachon, Brigitte; Vahsen, Sven; Valenta, Jan; Valente, Paolo; Valentinetti, Sara; Valkar, Stefan; Valladolid Gallego, Eva; Vallecorsa, Sofia; Valls Ferrer, Juan Antonio; van der Graaf, Harry; van der Kraaij, Erik; Van Der Leeuw, Robin; van der Poel, Egge; van der Ster, Daniel; van Eldik, Niels; van Gemmeren, Peter; van Kesteren, Zdenko; van Vulpen, Ivo; Vanadia, Marco; Vandelli, Wainer; Vandoni, Giovanna; Vaniachine, Alexandre; Vankov, Peter; Vannucci, Francois; Varela Rodriguez, Fernando; Vari, Riccardo; Varnes, Erich; Varouchas, Dimitris; Vartapetian, Armen; Varvell, Kevin; Vassilakopoulos, Vassilios; Vazeille, Francois; Vegni, Guido; Veillet, Jean-Jacques; Vellidis, Constantine; Veloso, Filipe; Veness, Raymond; Veneziano, Stefano; Ventura, Andrea; Ventura, Daniel; Venturi, Manuela; Venturi, Nicola; Vercesi, Valerio; Verducci, Monica; Verkerke, Wouter; Vermeulen, Jos; Vest, Anja; Vetterli, Michel; Vichou, Irene; Vickey, Trevor; Vickey Boeriu, Oana Elena; Viehhauser, Georg; Viel, Simon; Villa, Mauro; Villaplana Perez, Miguel; Vilucchi, Elisabetta; Vincter, Manuella; Vinek, Elisabeth; Vinogradov, Vladimir; Virchaux, Marc; Virzi, Joseph; Vitells, Ofer; Viti, Michele; Vivarelli, Iacopo; Vives Vaque, Francesc; Vlachos, Sotirios; Vladoiu, Dan; Vlasak, Michal; Vlasov, Nikolai; Vogel, Adrian; Vokac, Petr; Volpi, Guido; Volpi, Matteo; Volpini, Giovanni; von der Schmitt, Hans; von Loeben, Joerg; von Radziewski, Holger; von Toerne, Eckhard; Vorobel, Vit; Vorobiev, Alexander; Vorwerk, Volker; Vos, Marcel; Voss, Rudiger; Voss, Thorsten Tobias; Vossebeld, Joost; Vranjes, Nenad; Vranjes Milosavljevic, Marija; Vrba, Vaclav; Vreeswijk, Marcel; Vu Anh, Tuan; Vuillermet, Raphael; Vukotic, Ilija; Wagner, Wolfgang; Wagner, Peter; Wahlen, Helmut; Wakabayashi, Jun; Walbersloh, Jorg; Walch, Shannon; Walder, James; Walker, Rodney; Walkowiak, Wolfgang; Wall, Richard; Waller, Peter; Wang, Chiho; Wang, Haichen; Wang, Hulin; Wang, Jike; Wang, Jin; Wang, Joshua C; Wang, Rui; Wang, Song-Ming; Warburton, Andreas; Ward, Patricia; Warsinsky, Markus; Watkins, Peter; Watson, Alan; Watson, Ian; Watson, Miriam; Watts, Gordon; Watts, Stephen; Waugh, Anthony; Waugh, Ben; Weber, Marc; Weber, Michele; Weber, Pavel; Weidberg, Anthony; Weigell, Philipp; Weingarten, Jens; Weiser, Christian; Wellenstein, Hermann; Wells, Phillippa; Wen, Mei; Wenaus, Torre; Wendland, Dennis; Wendler, Shanti; Weng, Zhili; Wengler, Thorsten; Wenig, Siegfried; Wermes, Norbert; Werner, Matthias; Werner, Per; Werth, Michael; Wessels, Martin; Weydert, Carole; Whalen, Kathleen; Wheeler-Ellis, Sarah Jane; Whitaker, Scott; White, Andrew; White, Martin; Whitehead, Samuel Robert; Whiteson, Daniel; Whittington, Denver; Wicek, Francois; Wicke, Daniel; Wickens, Fred; Wiedenmann, Werner; Wielers, Monika; Wienemann, Peter; Wiglesworth, Craig; Wiik, Liv Antje Mari; Wijeratne, Peter Alexander; Wildauer, Andreas; Wildt, Martin Andre; Wilhelm, Ivan; Wilkens, Henric George; Will, Jonas Zacharias; Williams, Eric; Williams, Hugh; Willis, William; Willocq, Stephane; Wilson, John; Wilson, Michael Galante; Wilson, Alan; Wingerter-Seez, Isabelle; Winkelmann, Stefan; Winklmeier, Frank; Wittgen, Matthias; Wolter, Marcin Wladyslaw; Wolters, Helmut; Wong, Wei-Cheng; Wooden, Gemma; Wosiek, Barbara; Wotschack, Jorg; Woudstra, Martin; Wozniak, Krzysztof; Wraight, Kenneth; Wright, Catherine; Wright, Michael; Wrona, Bozydar; Wu, Sau Lan; Wu, Xin; Wu, Yusheng; Wulf, Evan; Wunstorf, Renate; Wynne, Benjamin; Xella, Stefania; Xiao, Meng; Xie, Song; Xie, Yigang; Xu, Chao; Xu, Da; Xu, Guofa; Yabsley, Bruce; Yacoob, Sahal; Yamada, Miho; Yamaguchi, Hiroshi; Yamamoto, Akira; Yamamoto, Kyoko; Yamamoto, Shimpei; Yamamura, Taiki; Yamanaka, Takashi; Yamaoka, Jared; Yamazaki, Takayuki; Yamazaki, Yuji; Yan, Zhen; Yang, Haijun; Yang, Un-Ki; Yang, Yi; Yang, Yi; Yang, Zhaoyu; Yanush, Serguei; Yao, Yushu; Yasu, Yoshiji; Ybeles Smit, Gabriel Valentijn; Ye, Jingbo; Ye, Shuwei; Yilmaz, Metin; Yoosoofmiya, Reza; Yorita, Kohei; Yoshida, Riktura; Young, Charles; Youssef, Saul; Yu, Dantong; Yu, Jaehoon; Yu, Jie; Yuan, Li; Yurkewicz, Adam; Zabinski, Bartlomiej; Zaets, Vassilli; Zaidan, Remi; Zaitsev, Alexander; Zajacova, Zuzana; Zanello, Lucia; Zarzhitsky, Pavel; Zaytsev, Alexander; Zeitnitz, Christian; Zeller, Michael; Zeman, Martin; Zemla, Andrzej; Zendler, Carolin; Zenin, Oleg; Ženiš, Tibor; Zenonos, Zenonas; Zenz, Seth; Zerwas, Dirk; Zevi della Porta, Giovanni; Zhan, Zhichao; Zhang, Dongliang; Zhang, Huaqiao; Zhang, Jinlong; Zhang, Xueyao; Zhang, Zhiqing; Zhao, Long; Zhao, Tianchi; Zhao, Zhengguo; Zhemchugov, Alexey; Zheng, Shuchen; Zhong, Jiahang; Zhou, Bing; Zhou, Ning; Zhou, Yue; Zhu, Cheng Guang; Zhu, Hongbo; Zhu, Junjie; Zhu, Yingchun; Zhuang, Xuai; Zhuravlov, Vadym; Zieminska, Daria; Zimmermann, Robert; Zimmermann, Simone; Zimmermann, Stephanie; Ziolkowski, Michael; Zitoun, Robert; Živković, Lidija; Zmouchko, Viatcheslav; Zobernig, Georg; Zoccoli, Antonio; Zolnierowski, Yves; Zsenei, Andras; zur Nedden, Martin; Zutshi, Vishnu; Zwalinski, Lukasz

    2013-03-02

    The uncertainty on the calorimeter energy response to jets of particles is derived for the ATLAS experiment at the Large Hadron Collider (LHC). First, the calorimeter response to single isolated charged hadrons is measured and compared to the Monte Carlo simulation using proton-proton collisions at centre-of-mass energies of $\\sqrt{s}$ = 900 GeV and 7 TeV collected during 2009 and 2010. Then, using the decay of K_s and Lambda particles, the calorimeter response to specific types of particles (positively and negatively charged pions, protons, and anti-protons) is measured and compared to the Monte Carlo predictions. Finally, the jet energy scale uncertainty is determined by propagating the response uncertainty for single charged and neutral particles to jets. The response uncertainty is 2-5% for central isolated hadrons and 1-3% for the final calorimeter jet energy scale.

  5. Anti-control of chaos of single time scale brushless dc motors and chaos synchronization of different order systems

    International Nuclear Information System (INIS)

    Ge Zhengming; Chang Chingming; Chen Yensheng

    2006-01-01

    Anti-control of chaos of single time scale brushless dc motors (BLDCM) and chaos synchronization of different order systems are studied in this paper. By addition of an external nonlinear term, we can obtain anti-control of chaos. Then, by addition of the coupling terms, by the use of Lyapunov stability theorem and by the linearization of the error dynamics, chaos synchronization between a third-order BLDCM and a second-order Duffing system are presented

  6. STM studies of an atomic-scale gate electrode formed by a single charged vacancy in GaAs

    Science.gov (United States)

    Lee, Donghun; Daughton, David; Gupta, Jay

    2009-03-01

    Electric-field control of spin-spin interactions at the atomic level is desirable for the realization of spintronics and spin-based quantum computation. Here we demonstrate the realization of an atomic-scale gate electrode formed by a single charged vacancy on the GaAs(110) surface[1]. We can position these vacancies with atomic precision using the tip of a home-built, low temperature STM. Tunneling spectroscopy of single Mn acceptors is used to quantify the electrostatic field as a function of distance from the vacancy. Single Mn acceptors are formed by substituting Mn adatoms for Ga atoms in the first layer of the p-GaAs(110) surface[2]. Depending on the distance, the in-gap resonance of single Mn acceptors can shift as much as 200meV. Our data indicate that the electrostatic field decays according to a screened Coulomb potential. The charge state of the vacancy can be switched to neutral, as evidenced by the Mn resonance returning to its unperturbed position. Reversible control of the local electric field as well as charged states of defects in semiconductors can open new insights such as realizing an atomic-scale gate control and studying spin-spin interactions in semiconductors. http://www.physics.ohio-state.edu/sim jgupta [1] D. Lee and J.A. Gupta (in preparation) [2] D. Kitchen et al., Nature 442, 436-439 (2006)

  7. Scales

    Science.gov (United States)

    Scales are a visible peeling or flaking of outer skin layers. These layers are called the stratum ... Scales may be caused by dry skin, certain inflammatory skin conditions, or infections. Examples of disorders that ...

  8. Plane-dependent ML scatter scaling: 3D extension of the 2D simulated single scatter (SSS) estimate

    Science.gov (United States)

    Rezaei, Ahmadreza; Salvo, Koen; Vahle, Thomas; Panin, Vladimir; Casey, Michael; Boada, Fernando; Defrise, Michel; Nuyts, Johan

    2017-08-01

    Scatter correction is typically done using a simulation of the single scatter, which is then scaled to account for multiple scatters and other possible model mismatches. This scaling factor is determined by fitting the simulated scatter sinogram to the measured sinogram, using only counts measured along LORs that do not intersect the patient body, i.e. ‘scatter-tails’. Extending previous work, we propose to scale the scatter with a plane dependent factor, which is determined as an additional unknown in the maximum likelihood (ML) reconstructions, using counts in the entire sinogram rather than only the ‘scatter-tails’. The ML-scaled scatter estimates are validated using a Monte-Carlo simulation of a NEMA-like phantom, a phantom scan with typical contrast ratios of a 68Ga-PSMA scan, and 23 whole-body 18F-FDG patient scans. On average, we observe a 12.2% change in the total amount of tracer activity of the MLEM reconstructions of our whole-body patient database when the proposed ML scatter scales are used. Furthermore, reconstructions using the ML-scaled scatter estimates are found to eliminate the typical ‘halo’ artifacts that are often observed in the vicinity of high focal uptake regions.

  9. The scaling of burnout data for a single fluid at a fixed pressure

    International Nuclear Information System (INIS)

    Kirby, G.J.

    1966-12-01

    The success of the scaling factor concept in linking burnout measurements made in two different fluids has been amply demonstrated. This memorandum investigates the possibility of linking measurements made on two different systems in the same fluid. It seems that good accuracy may be obtained for systems whose linear dimensions differ by as much as a factor of two; this offers the possibility of saving very substantial amounts of power in testing reactor fuel element. A novel conclusion is that systems do not need to be geometrically similar in order to be linked by scaling factors. (author)

  10. Multi-scale Modeling of Compressible Single-phase Flow in Porous Media using Molecular Simulation

    KAUST Repository

    Saad, Ahmed Mohamed

    2016-01-01

    potential model that accounts for the molecular quadrupole moment of fluids with non-spherical molecules such as CO2. The potential model was used to simulate the thermodynamic equilibrium properties for single-phase and two-phase systems using the canonical

  11. From a single pellet press to a bench scale pellet mill - Pelletizing six different biomass feedstocks

    DEFF Research Database (Denmark)

    Puig Arnavat, Maria; Shang, Lei; Sárossy, Zsuzsa

    2016-01-01

    The increasing demand for biomass pellets requires the investigation of alternative raw materials for pelletizetion. In the present paper, the pelletization process of fescue, alfalfa, sorghum, triticale, miscanthus and willow is studied to determine if results obtained in a single pellet press (...

  12. End-of-pipe single-sludge denitrification in pilot-scale recirculating aquaculture systems

    DEFF Research Database (Denmark)

    Suhr, Karin Isabel; Pedersen, Lars-Flemming; Nielsen, J.L.

    2014-01-01

    A step toward environmental sustainability of recirculat aquaculture systems (RAS) is implementation ofsingle-sludge denitrification, a process eliminating nitrate from the aqueous environment while reduc-ing the organic matter discharge simultaneously. Two 1700 L pilot-scale RAS systems each...

  13. Item analysis of single-peaked response data : the psychometric evaluation of bipolar measurement scales

    NARCIS (Netherlands)

    Polak, Maaike Geertruida

    2011-01-01

    The thesis explains the fundamental difference between unipolar and bipolar measurement scales for psychological characteristics. We explore the use of correspondence analysis (CA), a technique that is similar to principal component analysis and is available in SAS and SPSS, to select items that

  14. New algorithm for tensor contractions on multi-core CPUs, GPUs, and accelerators enables CCSD and EOM-CCSD calculations with over 1000 basis functions on a single compute node.

    Science.gov (United States)

    Kaliman, Ilya A; Krylov, Anna I

    2017-04-30

    A new hardware-agnostic contraction algorithm for tensors of arbitrary symmetry and sparsity is presented. The algorithm is implemented as a stand-alone open-source code libxm. This code is also integrated with general tensor library libtensor and with the Q-Chem quantum-chemistry package. An overview of the algorithm, its implementation, and benchmarks are presented. Similarly to other tensor software, the algorithm exploits efficient matrix multiplication libraries and assumes that tensors are stored in a block-tensor form. The distinguishing features of the algorithm are: (i) efficient repackaging of the individual blocks into large matrices and back, which affords efficient graphics processing unit (GPU)-enabled calculations without modifications of higher-level codes; (ii) fully asynchronous data transfer between disk storage and fast memory. The algorithm enables canonical all-electron coupled-cluster and equation-of-motion coupled-cluster calculations with single and double substitutions (CCSD and EOM-CCSD) with over 1000 basis functions on a single quad-GPU machine. We show that the algorithm exhibits predicted theoretical scaling for canonical CCSD calculations, O(N 6 ), irrespective of the data size on disk. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  15. madSTORM: a superresolution technique for large-scale multiplexing at single-molecule accuracy

    Science.gov (United States)

    Yi, Jason; Manna, Asit; Barr, Valarie A.; Hong, Jennifer; Neuman, Keir C.; Samelson, Lawrence E.

    2016-01-01

    Investigation of heterogeneous cellular structures using single-molecule localization microscopy has been limited by poorly defined localization accuracy and inadequate multiplexing capacity. Using fluorescent nanodiamonds as fiducial markers, we define and achieve localization precision required for single-molecule accuracy in dSTORM images. Coupled with this advance, our new multiplexing strategy, madSTORM, allows accurate targeting of multiple molecules using sequential binding and elution of fluorescent antibodies. madSTORM is used on an activated T-cell to localize 25 epitopes, 14 of which are on components of the same multimolecular T-cell receptor complex. We obtain an average localization precision of 2.6 nm, alignment error of 2.0 nm, and molecules within structures. Probing the molecular topology of complex signaling cascades and other heterogeneous networks is feasible with madSTORM. PMID:27708141

  16. Scaling from single molecule to macroscopic adhesion at polymer/metal interfaces.

    Science.gov (United States)

    Utzig, Thomas; Raman, Sangeetha; Valtiner, Markus

    2015-03-10

    Understanding the evolution of macroscopic adhesion based on fundamental molecular interactions is crucial to designing strong and smart polymer/metal interfaces that play an important role in many industrial and biomedical applications. Here we show how macroscopic adhesion can be predicted on the basis of single molecular interactions. In particular, we carry out dynamic single molecule-force spectroscopy (SM-AFM) in the framework of Bell-Evans' theory to gain information about the energy barrier between the bound and unbound states of an amine/gold junction. Furthermore, we use Jarzynski's equality to obtain the equilibrium ground-state energy difference of the amine/gold bond from these nonequilibrium force measurements. In addition, we perform surface forces apparatus (SFA) experiments to measure macroscopic adhesion forces at contacts where approximately 10(7) amine/gold bonds are formed simultaneously. The SFA approach provides an amine/gold interaction energy (normalized by the number of interacting molecules) of (36 ± 1)k(B)T, which is in excellent agreement with the interaction free energy of (35 ± 3)k(B)T calculated using Jarzynski's equality and single-molecule AFM experiments. Our results validate Jarzynski's equality for the field of polymer/metal interactions by measuring both sides of the equation. Furthermore, the comparison of SFA and AFM shows how macroscopic interaction energies can be predicted on the basis of single molecular interactions, providing a new strategy to potentially predict adhesive properties of novel glues or coatings as well as bio- and wet adhesion.

  17. The general behavior of NLO unintegrated parton distributions based on the single-scale evolution and the angular ordering constraint

    International Nuclear Information System (INIS)

    Hosseinkhani, H.; Modarres, M.

    2011-01-01

    To overcome the complexity of generalized two hard scale (k t ,μ) evolution equation, well known as the Ciafaloni, Catani, Fiorani and Marchesini (CCFM) evolution equations, and calculate the unintegrated parton distribution functions (UPDF), Kimber, Martin and Ryskin (KMR) proposed a procedure based on (i) the inclusion of single-scale (μ) only at the last step of evolution and (ii) the angular ordering constraint (AOC) on the DGLAP terms (the DGLAP collinear approximation), to bring the second scale, k t into the UPDF evolution equations. In this work we intend to use the MSTW2008 (Martin et al.) parton distribution functions (PDF) and try to calculate UPDF for various values of x (the longitudinal fraction of parton momentum), μ (the probe scale) and k t (the parton transverse momentum) to see the general behavior of three-dimensional UPDF at the NLO level up to the LHC working energy scales (μ 2 ). It is shown that there exits some pronounced peaks for the three-dimensional UPDF(f a (x,k t )) with respect to the two variables x and k t at various energies (μ). These peaks get larger and move to larger values of k t , as the energy (μ) is increased. We hope these peaks could be detected in the LHC experiments at CERN and other laboratories in the less exclusive processes.

  18. Gaussian approximation to single particle correlations at and below the picosecond scale for Lennard-Jones and nanoparticle fluids

    International Nuclear Information System (INIS)

    Van Zon, Ramses; Ashwin, S S; Cohen, E G D

    2008-01-01

    To describe short time (picosecond) and small scale (nanometre) transport in fluids, a Green's function approach was recently developed. This approach relies on an expansion of the distribution of single particle displacements around a Gaussian function, yielding an infinite series of correction terms. Applying a recent theorem (van Zon and Cohen 2006 J. Stat. Phys. 123 1–37) shows that for sufficiently small times the terms in this series become successively smaller, so that truncating the series near or at the Gaussian level might provide a good approximation. In this paper, we derive a theoretical estimate for the time scale at which truncating the series at or near the Gaussian level could be supposed to be accurate for equilibrium nanoscale systems. In order to numerically estimate this time scale, the coefficients for the first few terms in the series are determined in computer simulations for a Lennard-Jones (LJ) fluid, an isotopic LJ mixture and a suspension of a LJ-based model of nanoparticles in a LJ fluid. The results suggest that for LJ fluids an expansion around a Gaussian is accurate at time scales up to a picosecond, while for nanoparticles in suspension (a nanofluid), the characteristic time scale up to which the Gaussian is accurate becomes of the order of 5–10 ps. (invited article)

  19. Single-field consistency relations of large scale structure part III: test of the equivalence principle

    Energy Technology Data Exchange (ETDEWEB)

    Creminelli, Paolo [Abdus Salam International Centre for Theoretical Physics, Strada Costiera 11, Trieste, 34151 (Italy); Gleyzes, Jérôme; Vernizzi, Filippo [CEA, Institut de Physique Théorique, Gif-sur-Yvette cédex, F-91191 France (France); Hui, Lam [Physics Department and Institute for Strings, Cosmology and Astroparticle Physics, Columbia University, New York, NY, 10027 (United States); Simonović, Marko, E-mail: creminel@ictp.it, E-mail: jerome.gleyzes@cea.fr, E-mail: lhui@astro.columbia.edu, E-mail: msimonov@sissa.it, E-mail: filippo.vernizzi@cea.fr [SISSA, via Bonomea 265, Trieste, 34136 (Italy)

    2014-06-01

    The recently derived consistency relations for Large Scale Structure do not hold if the Equivalence Principle (EP) is violated. We show it explicitly in a toy model with two fluids, one of which is coupled to a fifth force. We explore the constraints that galaxy surveys can set on EP violation looking at the squeezed limit of the 3-point function involving two populations of objects. We find that one can explore EP violations of order 10{sup −3}÷10{sup −4} on cosmological scales. Chameleon models are already very constrained by the requirement of screening within the Solar System and only a very tiny region of the parameter space can be explored with this method. We show that no violation of the consistency relations is expected in Galileon models.

  20. Organic Single-Crystal Semiconductor Films on a Millimeter Domain Scale.

    Science.gov (United States)

    Kwon, Sooncheol; Kim, Jehan; Kim, Geunjin; Yu, Kilho; Jo, Yong-Ryun; Kim, Bong-Joong; Kim, Junghwan; Kang, Hongkyu; Park, Byoungwook; Lee, Kwanghee

    2015-11-18

    Nucleation and growth processes can be effectively controlled in organic semiconductor films through a new concept of template-mediated molecular crystal seeds during the phase transition; the effective control of these processes ensures millimeter-scale crystal domains, as well as the performance of the resulting organic films with intrinsic hole mobility of 18 cm(2) V(-1) s(-1). © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. Single molecule translocation in smectics illustrates the challenge for time-mapping in simulations on multiple scales.

    Science.gov (United States)

    Mukherjee, Biswaroop; Peter, Christine; Kremer, Kurt

    2017-09-21

    Understanding the connections between the characteristic dynamical time scales associated with a coarse-grained (CG) and a detailed representation is central to the applicability of the coarse-graining methods to understand molecular processes. The process of coarse graining leads to an accelerated dynamics, owing to the smoothening of the underlying free-energy landscapes. Often a single time-mapping factor is used to relate the time scales associated with the two representations. We critically examine this idea using a model system ideally suited for this purpose. Single molecular transport properties are studied via molecular dynamics simulations of the CG and atomistic representations of a liquid crystalline, azobenzene containing mesogen, simulated in the smectic and the isotropic phases. The out-of-plane dynamics in the smectic phase occurs via molecular hops from one smectic layer to the next. Hopping can occur via two mechanisms, with and without significant reorientation. The out-of-plane transport can be understood as a superposition of two (one associated with each mode of transport) independent continuous time random walks for which a single time-mapping factor would be rather inadequate. A comparison of the free-energy surfaces, relevant to the out-of-plane transport, qualitatively supports the above observations. Thus, this work underlines the need for building CG models that exhibit both structural and dynamical consistency to the underlying atomistic model.

  2. Single molecule translocation in smectics illustrates the challenge for time-mapping in simulations on multiple scales

    Science.gov (United States)

    Mukherjee, Biswaroop; Peter, Christine; Kremer, Kurt

    2017-09-01

    Understanding the connections between the characteristic dynamical time scales associated with a coarse-grained (CG) and a detailed representation is central to the applicability of the coarse-graining methods to understand molecular processes. The process of coarse graining leads to an accelerated dynamics, owing to the smoothening of the underlying free-energy landscapes. Often a single time-mapping factor is used to relate the time scales associated with the two representations. We critically examine this idea using a model system ideally suited for this purpose. Single molecular transport properties are studied via molecular dynamics simulations of the CG and atomistic representations of a liquid crystalline, azobenzene containing mesogen, simulated in the smectic and the isotropic phases. The out-of-plane dynamics in the smectic phase occurs via molecular hops from one smectic layer to the next. Hopping can occur via two mechanisms, with and without significant reorientation. The out-of-plane transport can be understood as a superposition of two (one associated with each mode of transport) independent continuous time random walks for which a single time-mapping factor would be rather inadequate. A comparison of the free-energy surfaces, relevant to the out-of-plane transport, qualitatively supports the above observations. Thus, this work underlines the need for building CG models that exhibit both structural and dynamical consistency to the underlying atomistic model.

  3. On the colour of wing scales in butterflies: iridescence and preferred orientation of single gyroid photonic crystals.

    Science.gov (United States)

    Corkery, Robert W; Tyrode, Eric C

    2017-08-06

    Lycaenid butterflies from the genera Callophrys , Cyanophrys and Thecla have evolved remarkable biophotonic gyroid nanostructures within their wing scales that have only recently been replicated by nanoscale additive manufacturing. These nanostructures selectively reflect parts of the visible spectrum to give their characteristic non-iridescent, matte-green appearance, despite a distinct blue-green-yellow iridescence predicted for individual crystals from theory. It has been hypothesized that the organism must achieve its uniform appearance by growing crystals with some restrictions on the possible distribution of orientations, yet preferential orientation observed in Callophrys rubi confirms that this distribution need not be uniform. By analysing scanning electron microscope and optical images of 912 crystals in three wing scales, we find no preference for their rotational alignment in the plane of the scales. However, crystal orientation normal to the scale was highly correlated to their colour at low (conical) angles of view and illumination. This correlation enabled the use of optical images, each containing up to 10 4 -10 5 crystals, for concluding the preferential alignment seen along the [Formula: see text] at the level of single scales, appears ubiquitous. By contrast, [Formula: see text] orientations were found to occur at no greater rate than that expected by chance. Above a critical cone angle, all crystals reflected bright green light indicating the dominant light scattering is due to the predicted band gap along the [Formula: see text] direction, independent of the domain orientation. Together with the natural variation in scale and wing shapes, we can readily understand the detailed mechanism of uniform colour production and iridescence suppression in these butterflies. It appears that the combination of preferential alignment normal to the wing scale, and uniform distribution within the plane is a near optimal solution for homogenizing the angular

  4. Node localization algorithm of wireless sensor networks for large electrical equipment monitoring application

    DEFF Research Database (Denmark)

    Chen, Qinyin; Hu, Y.; Chen, Zhe

    2016-01-01

    Node localization technology is an important technology for the Wireless Sensor Networks (WSNs) applications. An improved 3D node localization algorithm is proposed in this paper, which is based on a Multi-dimensional Scaling (MDS) node localization algorithm for large electrical equipment monito...

  5. Selective sentinel lymph node biopsy in papillary thyroid carcinoma in patients with no preoperative evidence of lymph node metastasis.

    Science.gov (United States)

    González, Óscar; Zafon, Carles; Caubet, Enric; García-Burillo, Amparo; Serres, Xavier; Fort, José Manuel; Mesa, Jordi; Castell, Joan; Roca, Isabel; Ramón Y Cajal, Santiago; Iglesias, Carmela

    2017-10-01

    Lymphadenectomy is recommended during surgery for papillary thyroid carcinoma when there is evidence of cervical lymph node metastasis (therapeutic) or in high-risk patients (prophylactic) such as those with T3 and T4 tumors of the TNM classification. Selective sentinel lymph node biopsy may improve preoperative diagnosis of nodal metastases. To analyze the results of selective sentinel lymph node biopsy in a group of patients with papillary thyroid carcinoma and no evidence of nodal involvement before surgery. A retrospective, single-center study in patients with papillary thyroid carcinoma and no clinical evidence of lymph node involvement who underwent surgery between 2011 and 2013. The sentinel node was identified by scintigraphy. When the sentinel node was positive, the affected compartment was removed, and when sentinel node was negative, central lymph node dissection was performed. Forty-three patients, 34 females, with a mean age of 52.3 (±17) years, were enrolled. Forty-six (27%) of the 170 SNs resected from 24 (55.8%) patients were positive for metastasis. In addition, 94 (15.6%) out of the 612 lymph nodes removed in the lymphadenectomies were positive for metastases. Twelve of the 30 (40%) low risk patients (cT1N0 and cT2N0) changed their stage to pN1, whereas 12 of 13 (92%) high risk patients (cT3N0 and cT4N0) changed to pN1 stage. Selective sentinel lymph node biopsy changes the stage of more than 50% of patients from cN0 to pN1. This confirms the need for lymph node resection in T3 and T4 tumors, but reveals the presence of lymph node metastases in 40% of T1-T2 tumors. Copyright © 2017 SEEN. Publicado por Elsevier España, S.L.U. All rights reserved.

  6. Tracking Single Units in Chronic, Large Scale, Neural Recordings for Brain Machine Interface Applications

    Directory of Open Access Journals (Sweden)

    Ahmed eEleryan

    2014-07-01

    Full Text Available In the study of population coding in neurobiological systems, tracking unit identity may be critical to assess possible changes in the coding properties of neuronal constituents over prolonged periods of time. Ensuring unit stability is even more critical for reliable neural decoding of motor variables in intra-cortically controlled brain-machine interfaces (BMIs. Variability in intrinsic spike patterns, tuning characteristics, and single-unit identity over chronic use is a major challenge to maintaining this stability, requiring frequent daily calibration of neural decoders in BMI sessions by an experienced human operator. Here, we report on a unit-stability tracking algorithm that efficiently and autonomously identifies putative single-units that are stable across many sessions using a relatively short duration recording interval at the start of each session. The algorithm first builds a database of features extracted from units' average spike waveforms and firing patterns across many days of recording. It then uses these features to decide whether spike occurrences on the same channel on one day belong to the same unit recorded on another day or not. We assessed the overall performance of the algorithm for different choices of features and classifiers trained using human expert judgment, and quantified it as a function of accuracy and execution time. Overall, we found a trade-off between accuracy and execution time with increasing data volumes from chronically implanted rhesus macaques, with an average of 12 seconds processing time per channel at ~90% classification accuracy. Furthermore, 77% of the resulting putative single-units matched those tracked by human experts. These results demonstrate that over the span of a few months of recordings, automated unit tracking can be performed with high accuracy and used to streamline the calibration phase during BMI sessions.

  7. Physical scale modeling of single free head piles under lateral loading in cohesive soils

    Directory of Open Access Journals (Sweden)

    Edgar Leonardo Salamanca-Medina

    2017-06-01

    Full Text Available This paper presents the results of the small scale modeling of free head wood piles under horizontal loading in cohesive soils, tested in order to compare the results with analytical models proposed by various authors. Characteristic Load (CLM and P-Y Curves methods were used for the prediction of lateral deflections at the head of the piles and the method proposed by Broms for estimating the ultimate lateral load. These predictions were compared with the results of the physical modeling, obtaining a good approximation between them.

  8. Scaling of dynamical decoupling for a single electron spin in nanodiamonds at room temperature

    International Nuclear Information System (INIS)

    Liu, Dong-Qi; Liu, Gang-Qin; Chang, Yan-Chun; Pan, Xin-Yu

    2014-01-01

    Overcoming the spin qubit decoherence is a challenge for quantum science and technology. We investigate the decoherence process in nanodiamonds by Carr–Purcell–Meiboom–Gill (CPMG) technique at room temperature. We find that the coherence time T 2 scales as n γ . The elongation effect of coherence time can be represented by a constant power of the number of pulses n. Considering the filter function of CPMG decoupling sequence as a δ function, the spectrum density of noise has been reconstructed directly from the coherence time measurements and a Lorentzian noise power spectrum model agrees well with the experiment. These results are helpful for the application of nanodiamonds to nanoscale magnetic imaging

  9. Probing Single Nanometer-scale Particles with Scanning Tunneling Microscopy and Spectroscopies

    International Nuclear Information System (INIS)

    McCarty, G.S.; Love, J.C.; Kushmerick, J.G.; Charles, L.F.; Keating, C.D.; Toleno, B.J.; Lyn, M.E.; Castleman, A.W.; Natan, M.J.; Weiss, P.S.

    1999-01-01

    Scanning tunneling microscopy can be used to isolate single particles on surfaces for further study. Local optical and electronic properties coupled with topographic information collected by the scanning tunneling microscope (STM) give insight into the intrinsic properties of the species under study. Since each spectroscopic measurement is done on a single particle, each sample is 'monodisperse', regardless of the degree of heterogeneity of the original preparation. We illustrate this with three example systems - a metal cluster of known atomic structure, metal nanoparticles dispersed from colloid suspensions, and metallocarbohedrenes (Met-Cars) deposited with other reaction products. Au and Ag nanoparticles were imaged using a photon emission STM. The threshold voltage, the lowest bias voltage at which photons are produced, was determined for Au nanoparticles. Electronic spectra of small clusters of Ni atoms on MoS 2 were recorded. Preliminary images of Zr-based Met-Car-containing soot were obtained on Au and MoS 2 substrates and partial electronic spectra were recorded of these possible Met-Car particles

  10. destiny: diffusion maps for large-scale single-cell data in R.

    Science.gov (United States)

    Angerer, Philipp; Haghverdi, Laleh; Büttner, Maren; Theis, Fabian J; Marr, Carsten; Buettner, Florian

    2016-04-15

    : Diffusion maps are a spectral method for non-linear dimension reduction and have recently been adapted for the visualization of single-cell expression data. Here we present destiny, an efficient R implementation of the diffusion map algorithm. Our package includes a single-cell specific noise model allowing for missing and censored values. In contrast to previous implementations, we further present an efficient nearest-neighbour approximation that allows for the processing of hundreds of thousands of cells and a functionality for projecting new data on existing diffusion maps. We exemplarily apply destiny to a recent time-resolved mass cytometry dataset of cellular reprogramming. destiny is an open-source R/Bioconductor package "bioconductor.org/packages/destiny" also available at www.helmholtz-muenchen.de/icb/destiny A detailed vignette describing functions and workflows is provided with the package. carsten.marr@helmholtz-muenchen.de or f.buettner@helmholtz-muenchen.de Supplementary data are available at Bioinformatics online. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  11. Time-scales for quenching single-bubble sonoluminescence in the presence of alcohols

    Science.gov (United States)

    Guan, Jingfeng; Matula, Thomas

    2002-11-01

    A small amount of alcohol added to water dramatically decreases the light intensity from single-bubble sonoluminescence [Weninger et al., J. Phys. Chem. 99, 14195-14197 (1995)]. From an excess accumulation at the bubble surface [Ashokkumar et al., J. Phys. Chem. 104, 8462-8465 (2000)], the molecules evaporate into the bubble interior, reducing the effective adiabatic exponent of the gas, and decreasing the bubble temperature and light output [Toegel et al., Phys. Rev. Lett. 84, 2509-2512 (2000)]. There is a debate as to the rate at which alcohol is injected into the bubble interior. One camp favors the notion that molecules must be repetitively injected over many acoustic cycles. Another camp favors the notion that most quenching occurs during a single collapse. An experiment has been conducted in order to resolve the debate. Quenching rates were measured by recording the instantaneous bubble response and corresponding light emission during a sudden increase in pressure. It was found that complete quenching in the presence of methanol requires over 8000 acoustic cycles, while quenching with butanol occurs in about 20 acoustic cycles. These observations are consistent with the view that quenching requires the repetitive injection of alcohol molecules over repetitive acoustic cycles.

  12. Micro-positron emission tomography for measuring sub-core scale single and multiphase transport parameters in porous media

    Science.gov (United States)

    Zahasky, Christopher; Benson, Sally M.

    2018-05-01

    Accurate descriptions of heterogeneity in porous media are important for understanding and modeling single phase (e.g. contaminant transport, saltwater intrusion) and multiphase (e.g. geologic carbon storage, enhanced oil recovery) transport problems. Application of medical imaging to experimentally quantify these processes has led to significant progress in material characterization and understanding fluid transport behavior at laboratory scales. While widely utilized in cancer diagnosis and management, cardiology, and neurology, positron emission tomography (PET) has had relatively limited applications in earth science. This study utilizes a small-bore micro-PET scanner to image and quantify the transport behavior of pulses of a conservative aqueous radiotracer injected during single and multiphase flow experiments in two heterogeneous Berea sandstone cores. The cores are discretized into axial-parallel streamtubes, and using the reconstructed micro-PET data, expressions are derived from spatial moment analysis for calculating sub-core tracer flux and pore water velocity. Using the flux and velocity measurements, it is possible to calculate porosity and saturation from volumetric flux balance, and calculate permeability and water relative permeability from Darcy's law. Second spatial moment analysis enables measurement of sub-core solute dispersion during both single phase and multiphase experiments. A numerical simulation model is developed to verify the assumptions of the streamtube dimension reduction technique. A variation of the reactor ratio is presented as a diagnostic metric to efficiently determine the validity of the streamtube approximation in core and column-scale experiments. This study introduces a new method to quantify sub-core permeability, relative permeability, and dispersion. These experimental and analytical methods provide a foundation for future work on experimental measurements of differences in transport behavior across scales.

  13. Probing dynamics and pinning of single vortices in superconductors at nanometer scales

    Science.gov (United States)

    Embon, L.; Anahory, Y.; Suhov, A.; Halbertal, D.; Cuppens, J.; Yakovenko, A.; Uri, A.; Myasoedov, Y.; Rappaport, M. L.; Huber, M. E.; Gurevich, A.; Zeldov, E.

    2015-01-01

    The dynamics of quantized magnetic vortices and their pinning by materials defects determine electromagnetic properties of superconductors, particularly their ability to carry non-dissipative currents. Despite recent advances in the understanding of the complex physics of vortex matter, the behavior of vortices driven by current through a multi-scale potential of the actual materials defects is still not well understood, mostly due to the scarcity of appropriate experimental tools capable of tracing vortex trajectories on nanometer scales. Using a novel scanning superconducting quantum interference microscope we report here an investigation of controlled dynamics of vortices in lead films with sub-Angstrom spatial resolution and unprecedented sensitivity. We measured, for the first time, the fundamental dependence of the elementary pinning force of multiple defects on the vortex displacement, revealing a far more complex behavior than has previously been recognized, including striking spring softening and broken-spring depinning, as well as spontaneous hysteretic switching between cellular vortex trajectories. Our results indicate the importance of thermal fluctuations even at 4.2 K and of the vital role of ripples in the pinning potential, giving new insights into the mechanisms of magnetic relaxation and electromagnetic response of superconductors.

  14. Increasing power generation for scaling up single-chamber air cathode microbial fuel cells

    KAUST Repository

    Cheng, Shaoan; Logan, Bruce E.

    2011-01-01

    Scaling up microbial fuel cells (MFCs) requires a better understanding the importance of the different factors such as electrode surface area and reactor geometry relative to solution conditions such as conductivity and substrate concentration. It is shown here that the substrate concentration has significant effect on anode but not cathode performance, while the solution conductivity has a significant effect on the cathode but not the anode. The cathode surface area is always important for increasing power. Doubling the cathode size can increase power by 62% with domestic wastewater, but doubling the anode size increases power by 12%. Volumetric power density was shown to be a linear function of cathode specific surface area (ratio of cathode surface area to reactor volume), but the impact of cathode size on power generation depended on the substrate strength (COD) and conductivity. These results demonstrate the cathode specific surface area is the most critical factor for scaling-up MFCs to obtain high power densities. © 2010 Elsevier Ltd.

  15. Increasing power generation for scaling up single-chamber air cathode microbial fuel cells

    KAUST Repository

    Cheng, Shaoan

    2011-03-01

    Scaling up microbial fuel cells (MFCs) requires a better understanding the importance of the different factors such as electrode surface area and reactor geometry relative to solution conditions such as conductivity and substrate concentration. It is shown here that the substrate concentration has significant effect on anode but not cathode performance, while the solution conductivity has a significant effect on the cathode but not the anode. The cathode surface area is always important for increasing power. Doubling the cathode size can increase power by 62% with domestic wastewater, but doubling the anode size increases power by 12%. Volumetric power density was shown to be a linear function of cathode specific surface area (ratio of cathode surface area to reactor volume), but the impact of cathode size on power generation depended on the substrate strength (COD) and conductivity. These results demonstrate the cathode specific surface area is the most critical factor for scaling-up MFCs to obtain high power densities. © 2010 Elsevier Ltd.

  16. Single-Event Upset and Scaling Trends in New Generation of the Commercial SOI PowerPC Microprocessors

    Science.gov (United States)

    Irom, Farokh; Farmanesh, Farhad; Kouba, Coy K.

    2006-01-01

    Single-event upset effects from heavy ions are measured for Motorola silicon-on-insulator (SOI) microprocessor with 90 nm feature sizes. The results are compared with previous results for SOI microprocessors with feature sizes of 130 and 180 nm. The cross section of the 90 nm SOI processors is smaller than results for 130 and 180 nm counterparts, but the threshold is about the same. The scaling of the cross section with reduction of feature size and core voltage for SOI microprocessors is discussed.

  17. Subchannel Scale Thermal-Hydraulic Analysis of Rod Bundle Geometry under Single-phase Adiabatic Conditions Using CUPID

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Seok Jong; Park, Goon Cherl; Cho, Hyoung Kyu [KAERI, Daejeon (Korea, Republic of)

    2016-05-15

    In Korea, subchannel analysis code, MATRA has been developed by KAERI (Korea Atomic Energy Research Institute). MATRA has been used for reactor core T/H design and DNBR (Departure from Nucleate Boiling Ratio) calculation. Also, the code has been successfully coupled with neutronics code and fuel analysis code. However, since major concern of the code is not the accident simulation, some features of the code are not optimized for the accident conditions, such as the homogeneous model for two-phase flow and spatial marching method for numerical scheme. For this reason, in the present study, application of CUPID for the subchannel scale T/H analysis in rod bundle geometry was conducted. CUPID is a component scale T/H analysis code which adopts three dimensional two-fluid three-field model developed by KAERI. In this paper, the validation results of the CUPID code for subchannel scale rod bundle analysis at single phase adiabatic conditions were presented. At first, the physical models required for a subchannel scale analysis were implemented to CUPID. In the future, the scope of validation tests will be extended to diabetic and two phase flow conditions and required models will be implemented into CUPID.

  18. Validation of the Single-Factor Model of the Relationship Assessment Scale among Married and Cohabiting Persons from Monterrey, Mexico

    Directory of Open Access Journals (Sweden)

    José Moral de la Rubia

    2015-07-01

    Full Text Available The study of intimate partner relationships is particularly important because this union is the foundation of the family. Satisfaction with the relationship can be defined as the overall attitude to the relationship and the partner. The Hendrick's Relationship Assessment Scale (RAS is a instrument commonly used to assess the construct. Previous research papers have showed that this scale has high internal consistency and a single-factor structure. Although there are validation studies of the RAS, these studies used inappropriate statistical techniques to analyze its Likert-type items, and to determine the number of factors; likewise, its factor invariance across sex has not been previously contrasted. Therefore, this study posed the following research questions: Does the RAS have consistent and discriminating items? Basing the analysis on a polychoric correlation matrix, what is its level of internal consistency? How many factors emerge using rigorous empirical methods? Is the single-factor model invariant across sex? In order to answer these research questions, we used a random route probability sampling in this instrument validation study of the RAS. The sample was extracted from the population of married couples or the ones living in consensual union in Monterrey, Mexico. There were 431 female and 376 male participants in the study. The RAS’ items were consistent and discriminative. The internal consistency of the scale was excellent in the whole sample (ordinal α = .93, as well as among female (ordinal α = .94 and male participants (ordinal α = .92. Horn's parallel analysis and Velicer's  minimum average partial test suggested a one factor solution. Moreover, the single-factor model (with one correlation between the residuals of the two negatively worded items had a close fit to the data, and its properties of invariance across sex were very acceptable by the Unweighted Least Squares method. We conclude that the scale shows internal

  19. Electrical contacts to nanorod networks at different length scales: From macroscale ensembles to single nanorod chains

    KAUST Repository

    Lavieville, Romain; Zhang, Yang; Di Fabrizio, Enzo M.; Krahne, Roman

    2013-01-01

    The nature of metal-semiconductor interfaces at the nanoscale is an important issue in micro- and nanoelectronic engineering. The study of charge transport through chains of CdSe semiconductor nanorods linked by Au particles represents an ideal model system for this matter, because the metal semiconductor interface is an intrinsic feature of the nanosystem. Here we show the controlled fabrication of all-inorganic hybrid metal-semiconductor networks with different size, in which the semiconductor nanorods are linked by Au domains at their tips. We demonstrate different approaches to selectively contact the networks and single nanorod chains with planar electrodes, and we investigate their charge transport at room temperature. © 2013 Elsevier B.V. All rights reserved.

  20. Electrical contacts to nanorod networks at different length scales: From macroscale ensembles to single nanorod chains

    KAUST Repository

    Lavieville, Romain

    2013-11-01

    The nature of metal-semiconductor interfaces at the nanoscale is an important issue in micro- and nanoelectronic engineering. The study of charge transport through chains of CdSe semiconductor nanorods linked by Au particles represents an ideal model system for this matter, because the metal semiconductor interface is an intrinsic feature of the nanosystem. Here we show the controlled fabrication of all-inorganic hybrid metal-semiconductor networks with different size, in which the semiconductor nanorods are linked by Au domains at their tips. We demonstrate different approaches to selectively contact the networks and single nanorod chains with planar electrodes, and we investigate their charge transport at room temperature. © 2013 Elsevier B.V. All rights reserved.

  1. Sentinel nodes outside lymph node basins in patients with melanoma

    NARCIS (Netherlands)

    Roozendaal, GK; de Vries, JDH; van Poll, D; Jansen, L; Nieweg, OE; Kroon, BBR; Schraffordt Koops, H.

    Background: Lymphoscintigraphy occasionally reveals hot spots outside lymph node basins in patients with melanoma. The aim of this study was to evaluate such abnormally located hot spots. Methods: Sentinel node biopsy was studied prospectively in 379 patients with clinically localized cutaneous

  2. Contact angle goniometry on single micron-scale fibers for composites

    DEFF Research Database (Denmark)

    Hansen, Daniel; Bomholt, Niels; Jeppesen, Jonas Camillus

    2017-01-01

    Probing the wetting properties of microfibers by polymer resins is of significant interest for the rational design of composite materials. Here, we demonstrate the measurement of contact angles on wetted micron scale fibers by imaging the fluid meniscus with telecentric optics at a spatial...... resolution of 4 um followed by automated image analysis. The meniscus is described as a catenary in the zero gravity approximation and by fitting this to the measured profile, the contact angle is obtained at the intersection between the fluid and the fiber surface. The method is validated by measuring...... agreement between con-tact angles for the PMMA/H2O system for fibers with diameters 20–800 um and for sessile drops. The ability of the method to discriminate contact angles for a series of commercial glass fibers against epoxy resin is successfully demonstrated. AFM imaging shows that the surface...

  3. Scaling of dynamical decoupling for a single electron spin in nanodiamonds at room temperature

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Dong-Qi; Liu, Gang-Qin; Chang, Yan-Chun; Pan, Xin-Yu, E-mail: xypan@aphy.iphy.ac.cn

    2014-01-01

    Overcoming the spin qubit decoherence is a challenge for quantum science and technology. We investigate the decoherence process in nanodiamonds by Carr–Purcell–Meiboom–Gill (CPMG) technique at room temperature. We find that the coherence time T{sub 2} scales as n{sup γ}. The elongation effect of coherence time can be represented by a constant power of the number of pulses n. Considering the filter function of CPMG decoupling sequence as a δ function, the spectrum density of noise has been reconstructed directly from the coherence time measurements and a Lorentzian noise power spectrum model agrees well with the experiment. These results are helpful for the application of nanodiamonds to nanoscale magnetic imaging.

  4. 15 years of zooming in and zooming out: Developing a new single scale national active fault database of New Zealand

    Science.gov (United States)

    Ries, William; Langridge, Robert; Villamor, Pilar; Litchfield, Nicola; Van Dissen, Russ; Townsend, Dougal; Lee, Julie; Heron, David; Lukovic, Biljana

    2014-05-01

    In New Zealand, we are currently reconciling multiple digital coverages of mapped active faults into a national coverage at a single scale (1:250,000). This seems at first glance to be a relatively simple task. However, methods used to capture data, the scale of capture, and the initial purpose of the fault mapping, has produced datasets that have very different characteristics. The New Zealand digital active fault database (AFDB) was initially developed as a way of managing active fault locations and fault-related features within a computer-based spatial framework. The data contained within the AFDB comes from a wide range of studies, from plate tectonic (1:500,000) to cadastral (1:2,000) scale. The database was designed to allow capture of field observations and remotely sourced data without a loss in data resolution. This approach has worked well as a method for compiling a centralised database for fault information but not for providing a complete national coverage at a single scale. During the last 15 years other complementary projects have used and also contributed data to the AFDB, most notably the QMAP project (a national series of geological maps completed over 19 years that include coverage of active and inactive faults at 1:250,000). AFDB linework and attributes was incorporated into this series but simplification of linework and attributes has occurred to maintain map clarity at 1:250,000 scale. Also, during this period on-going mapping of active faults has improved upon these data. Other projects of note that have used data from the AFDB include the National Seismic Hazard Model of New Zealand and the Global Earthquake Model (GEM). The main goal of the current project has been to provide the best digital spatial representation of a fault trace at 1:250,000 scale and combine this with the most up to date attributes. In some areas this has required a simplification of very fine detailed data and in some cases new mapping to provide a complete coverage

  5. Chemical shift effect predicting lymph node status in rectal cancer using high-resolution MR imaging with node-for-node matched histopathological validation

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Hongmei; Zhang, Chongda; Ye, Feng; Liu, Yuan; Zhou, Chunwu [Chinese Academy of Medical Sciences and Peking Union Medical College, Department of Diagnostic Radiology, National Cancer Center/Cancer Hospital, ChaoYang District, Beijing (China); Zheng, Zhaoxu [Chinese Academy of Medical Sciences and Peking Union Medical College, Department of Colorectal Oncology, National Cancer Center/Cancer Hospital, ChaoYang District, Beijing (China); Zou, Shuangmei [Chinese Academy of Medical Sciences and Peking Union Medical College, Department of Pathology, National Cancer Center/Cancer Hospital, ChaoYang District, Beijing (China)

    2017-09-15

    To evaluate the value of the chemical shift effect (CSE) as well as other criteria for the prediction of lymph node status. Twenty-nine patients who underwent radical surgery of rectal cancers were studied with pre- and postoperative specimen MRI. Lymph nodes were harvested from transverse whole-mount specimens and compared with in vivo and ex vivo images to obtain a precise slice-for-section match. Preoperative MR characteristics including CSE, as well as other predictors, were evaluated by two readers independently between benign and metastatic nodes. A total of 255 benign and 35 metastatic nodes were obtained; 71.4% and 69.4% of benign nodes were detected with regular CSE for two readers, whereas 80.0% and 74.3% of metastatic nodes with absence of CSE. The CSE rendered areas under the ROC curve (AUC) of 0.879 and 0.845 for predicting nodal status for two readers. The criteria of nodal location, border, signal intensity and minimum distance to the rectal wall were also useful but with AUCs (0.629-0.743) lower than those of CSE. CSE is a reliable predictor for differentiating benign from metastatic nodes. Additional criteria should be taken into account when it is difficult to determine the nodal status by using only a single predictor. (orig.)

  6. Utilisation of Decision Tables for Proposal of Transfer Node Conception

    Directory of Open Access Journals (Sweden)

    Martin Jacura

    2012-09-01

    Full Text Available The key issue in improving the appeal of public mass transport is the optimal arrangement of transfer nodes. The objective is to propose a comfortable, simple and safe environment for both passengers and operators, and a solution which is economical to construct and operate. Although each transfer node is unique and specific, it is beneficial to have a general idea on the layout of a project to construct or reconstruct such a transfer node. This project should, in particular, stem from the traffic intensity of single transport modes, the volume of single transfer links, and the nature and significance of traffic routes. This article presents the methodology for determining the appropriate disposition of mass public transport nodes using modified decision tables (one of the tools of systems analysis with specific data particularly applicable in the Czech Republic.

  7. Nanometer-scale discernment of field emission from tungsten surface with single carbon monoxide molecule

    Science.gov (United States)

    Matsunaga, Soichiro; Suwa, Yuji; Katagiri, Souichi

    2017-12-01

    Unusual quantized beam fluctuations were found in the emission current from a cold-field emitter (CFE) operating in an extremely high vacuum of 10-10 Pa. To clarify the microscopic mechanism behind these fluctuations, we developed a new calculation method to evaluate the field emission from a heterogeneous surface under a strong electric field of 4 × 109 V/m by using the local potential distribution obtained by a first-principles calculation, instead of by using the work function. As a result of the first-principles calculations of a single molecule adsorbed on a tungsten surface, we found that dissociative adsorption of a carbon monoxide (CO) molecule enhances the emission current by changing the potential barrier in the area surrounding the C and O adatoms when these two atoms are placed at their most stable positions. It is also found that the migration of the O atom from the most stable position reduces the emission current. These types of enhancement and reduction of the emission current quantitatively explain the observed quantized fluctuations of the CFE emission current.

  8. In situ probing the interior of single bacterial cells at nanometer scale

    International Nuclear Information System (INIS)

    Liu, Boyin; Wah Ng, Tuck; Fu, Jing; Hemayet Uddin, Md; Paterson, David L; Velkov, Tony; Li, Jian

    2014-01-01

    We report a novel approach to probe the interior of single bacterial cells at nanometre resolution by combining focused ion beam (FIB) and atomic force microscopy (AFM). After removing layers of pre-defined thickness in the order of 100 nm on the target bacterial cells with FIB milling, AFM of different modes can be employed to probe the cellular interior under both ambient and aqueous environments. Our initial investigations focused on the surface topology induced by FIB milling and the hydration effects on AFM measurements, followed by assessment of the sample protocols. With fine-tuning of the process parameters, in situ AFM probing beneath the bacterial cell wall was achieved for the first time. We further demonstrate the proposed method by performing a spatial mapping of intracellular elasticity and chemistry of the multi-drug resistant strain Klebsiella pneumoniae cells prior to and after it was exposed to the ‘last-line’ antibiotic polymyxin B. Our results revealed increased stiffness occurring in both surface and interior regions of the treated cells, suggesting loss of integrity of the outer membrane from polymyxin treatments. In addition, the hydrophobicity measurement using a functionalized AFM tip was able to highlight the evident hydrophobic portion of the cell such as the regions containing cell membrane. We expect that the proposed FIB–AFM platform will help in gaining deeper insights of bacteria–drug interactions to develop potential strategies for combating multi-drug resistance. (paper)

  9. Creep lifing methodologies applied to a single crystal superalloy by use of small scale test techniques

    Energy Technology Data Exchange (ETDEWEB)

    Jeffs, S.P., E-mail: s.p.jeffs@swansea.ac.uk [Institute of Structural Materials, Swansea University, Singleton Park SA2 8PP (United Kingdom); Lancaster, R.J. [Institute of Structural Materials, Swansea University, Singleton Park SA2 8PP (United Kingdom); Garcia, T.E. [IUTA (University Institute of Industrial Technology of Asturias), University of Oviedo, Edificio Departamental Oeste 7.1.17, Campus Universitario, 33203 Gijón (Spain)

    2015-06-11

    In recent years, advances in creep data interpretation have been achieved either by modified Monkman–Grant relationships or through the more contemporary Wilshire equations, which offer the opportunity of predicting long term behaviour extrapolated from short term results. Long term lifing techniques prove extremely useful in creep dominated applications, such as in the power generation industry and in particular nuclear where large static loads are applied, equally a reduction in lead time for new alloy implementation within the industry is critical. The latter requirement brings about the utilisation of the small punch (SP) creep test, a widely recognised approach for obtaining useful mechanical property information from limited material volumes, as is typically the case with novel alloy development and for any in-situ mechanical testing that may be required. The ability to correlate SP creep results with uniaxial data is vital when considering the benefits of the technique. As such an equation has been developed, known as the k{sub SP} method, which has been proven to be an effective tool across several material systems. The current work now explores the application of the aforementioned empirical approaches to correlate small punch creep data obtained on a single crystal superalloy over a range of elevated temperatures. Finite element modelling through ABAQUS software based on the uniaxial creep data has also been implemented to characterise the SP deformation and help corroborate the experimental results.

  10. Creep lifing methodologies applied to a single crystal superalloy by use of small scale test techniques

    International Nuclear Information System (INIS)

    Jeffs, S.P.; Lancaster, R.J.; Garcia, T.E.

    2015-01-01

    In recent years, advances in creep data interpretation have been achieved either by modified Monkman–Grant relationships or through the more contemporary Wilshire equations, which offer the opportunity of predicting long term behaviour extrapolated from short term results. Long term lifing techniques prove extremely useful in creep dominated applications, such as in the power generation industry and in particular nuclear where large static loads are applied, equally a reduction in lead time for new alloy implementation within the industry is critical. The latter requirement brings about the utilisation of the small punch (SP) creep test, a widely recognised approach for obtaining useful mechanical property information from limited material volumes, as is typically the case with novel alloy development and for any in-situ mechanical testing that may be required. The ability to correlate SP creep results with uniaxial data is vital when considering the benefits of the technique. As such an equation has been developed, known as the k SP method, which has been proven to be an effective tool across several material systems. The current work now explores the application of the aforementioned empirical approaches to correlate small punch creep data obtained on a single crystal superalloy over a range of elevated temperatures. Finite element modelling through ABAQUS software based on the uniaxial creep data has also been implemented to characterise the SP deformation and help corroborate the experimental results

  11. Similarity analysis and scaling criteria for LWRs under single-phase and two-phase natural circulation

    International Nuclear Information System (INIS)

    Ishii, M.; Kataoka, I.

    1983-03-01

    Scaling criteria for a natural circulation loop under single phase and two-phase flow conditions have been derived. For a single phase case the continuity, integral momentum, and energy equations in one-dimensional area average forms have been used. From this, the geometrical similarity groups, friction number, Richardson number, characteristic time constant ratio, Biot number, and heat source number are obtained. The Biot number involves the heat transfer coefficient which may cause some difficulties in simulating the turbulent flow regime. For a two-phase flow case, the similarity groups obtained from a perturbation analysis based on the one-dimensional drift-flux model have been used. The physical significance of the phase change number, subcooling number, drift-flux number, friction number are discussed and conditions imposed by these groups are evaluated. In the two-phase flow case, the critical heat flux is one of the most important transients which should be simulated in a scale model. The above results are applied to the LOFT facility in case of a natural circulation simulation. Some preliminary conclusions on the feasibility of the facility have been obtained

  12. Similarity analysis and scaling criteria for LWRs under single-phase and two-phase natural circulation

    Energy Technology Data Exchange (ETDEWEB)

    Ishii, M.; Kataoka, I.

    1983-03-01

    Scaling criteria for a natural circulation loop under single phase and two-phase flow conditions have been derived. For a single phase case the continuity, integral momentum, and energy equations in one-dimensional area average forms have been used. From this, the geometrical similarity groups, friction number, Richardson number, characteristic time constant ratio, Biot number, and heat source number are obtained. The Biot number involves the heat transfer coefficient which may cause some difficulties in simulating the turbulent flow regime. For a two-phase flow case, the similarity groups obtained from a perturbation analysis based on the one-dimensional drift-flux model have been used. The physical significance of the phase change number, subcooling number, drift-flux number, friction number are discussed and conditions imposed by these groups are evaluated. In the two-phase flow case, the critical heat flux is one of the most important transients which should be simulated in a scale model. The above results are applied to the LOFT facility in case of a natural circulation simulation. Some preliminary conclusions on the feasibility of the facility have been obtained.

  13. Estimation of high-pT Jet Energy Scale Uncertainty from single hadron response with the ATLAS detector

    CERN Document Server

    AUTHOR|(INSPIRE)INSPIRE-00534683; The ATLAS collaboration

    2016-01-01

    The jet energy scale (JES) uncertainty is estimated using different methods at different pT ranges. In situ techniques exploiting the pT balance between a jet and a reference object (e.g. Z or gamma) are used at lower pT, but at very high pT (> 2.5 TeV) there is not enough statistics for in-situ techniques. The JES uncertainty at high-pT is important in several searches for new phenomena, e.g. the dijet resonance and angular searches. In the highest pT range, the JES uncertainty is estimated using the calorimeter response to single hadrons. In this method, jets are treated as a superposition of energy depositions of single particles. An uncertainty is applied to each energy depositions belonging to the particles within the jet, and propagated to the final jet energy scale. This poster presents the JES uncertainty found with this method at sqrt(s) = 8 TeV and its developments.

  14. Identifying Vulnerable Nodes of Complex Networks in Cascading Failures Induced by Node-Based Attacks

    Directory of Open Access Journals (Sweden)

    Shudong Li

    2013-01-01

    Full Text Available In the research on network security, distinguishing the vulnerable components of networks is very important for protecting infrastructures systems. Here, we probe how to identify the vulnerable nodes of complex networks in cascading failures, which was ignored before. Concerned with random attack (RA and highest load attack (HL on nodes, we model cascading dynamics of complex networks. Then, we introduce four kinds of weighting methods to characterize the nodes of networks including Barabási-Albert scale-free networks (SF, Watts-Strogatz small-world networks (WS, Erdos-Renyi random networks (ER, and two real-world networks. The simulations show that, for SF networks under HL attack, the nodes with small value of the fourth kind of weight are the most vulnerable and the ones with small value of the third weight are also vulnerable. Also, the real-world autonomous system with power-law distribution verifies these findings. Moreover, for WS and ER networks under both RA and HL attack, when the nodes have low tolerant ability, the ones with small value of the fourth kind of weight are more vulnerable and also the ones with high degree are easier to break down. The results give us important theoretical basis for digging the potential safety loophole and making protection strategy.

  15. Optimizing fusion PIC code performance at scale on Cori Phase 2

    Energy Technology Data Exchange (ETDEWEB)

    Koskela, T. S.; Deslippe, J.

    2017-07-23

    In this paper we present the results of optimizing the performance of the gyrokinetic full-f fusion PIC code XGC1 on the Cori Phase Two Knights Landing system. The code has undergone substantial development to enable the use of vector instructions in its most expensive kernels within the NERSC Exascale Science Applications Program. We study the single-node performance of the code on an absolute scale using the roofline methodology to guide optimization efforts. We have obtained 2x speedups in single node performance due to enabling vectorization and performing memory layout optimizations. On multiple nodes, the code is shown to scale well up to 4000 nodes, near half the size of the machine. We discuss some communication bottlenecks that were identified and resolved during the work.

  16. Nano-scale microfluidics to study 3D chemotaxis at the single cell level.

    Directory of Open Access Journals (Sweden)

    Corina Frick

    Full Text Available Directed migration of cells relies on their ability to sense directional guidance cues and to interact with pericellular structures in order to transduce contractile cytoskeletal- into mechanical forces. These biomechanical processes depend highly on microenvironmental factors such as exposure to 2D surfaces or 3D matrices. In vivo, the majority of cells are exposed to 3D environments. Data on 3D cell migration are mostly derived from intravital microscopy or collagen-based in vitro assays. Both approaches offer only limited controllability of experimental conditions. Here, we developed an automated microfluidic system that allows positioning of cells in 3D microenvironments containing highly controlled diffusion-based chemokine gradients. Tracking migration in such gradients was feasible in real time at the single cell level. Moreover, the setup allowed on-chip immunocytochemistry and thus linking of functional with phenotypical properties in individual cells. Spatially defined retrieval of cells from the device allows down-stream off-chip analysis. Using dendritic cells as a model, our setup specifically allowed us for the first time to quantitate key migration characteristics of cells exposed to identical gradients of the chemokine CCL19 yet placed on 2D vs in 3D environments. Migration properties between 2D and 3D migration were distinct. Morphological features of cells migrating in an in vitro 3D environment were similar to those of cells migrating in animal tissues, but different from cells migrating on a surface. Our system thus offers a highly controllable in vitro-mimic of a 3D environment that cells traffic in vivo.

  17. Comparative analysis of single-step and two-step biodiesel production using supercritical methanol on laboratory-scale

    International Nuclear Information System (INIS)

    Micic, Radoslav D.; Tomić, Milan D.; Kiss, Ferenc E.; Martinovic, Ferenc L.; Simikić, Mirko Ð.; Molnar, Tibor T.

    2016-01-01

    Highlights: • Single-step supercritical transesterification compared to the two-step process. • Two-step process: oil hydrolysis and subsequent supercritical methyl esterification. • Experiments were conducted in a laboratory-scale batch reactor. • Higher biodiesel yields in two-step process at milder reaction conditions. • Two-step process has potential to be cost-competitive with the single-step process. - Abstract: Single-step supercritical transesterification and two-step biodiesel production process consisting of oil hydrolysis and subsequent supercritical methyl esterification were studied and compared. For this purpose, comparative experiments were conducted in a laboratory-scale batch reactor and optimal reaction conditions (temperature, pressure, molar ratio and time) were determined. Results indicate that in comparison to a single-step transesterification, methyl esterification (second step of the two-step process) produces higher biodiesel yields (95 wt% vs. 91 wt%) at lower temperatures (270 °C vs. 350 °C), pressures (8 MPa vs. 12 MPa) and methanol to oil molar ratios (1:20 vs. 1:42). This can be explained by the fact that the reaction system consisting of free fatty acid (FFA) and methanol achieves supercritical condition at milder reaction conditions. Furthermore, the dissolved FFA increases the acidity of supercritical methanol and acts as an acid catalyst that increases the reaction rate. There is a direct correlation between FFA content of the product obtained in hydrolysis and biodiesel yields in methyl esterification. Therefore, the reaction parameters of hydrolysis were optimized to yield the highest FFA content at 12 MPa, 250 °C and 1:20 oil to water molar ratio. Results of direct material and energy costs comparison suggest that the process based on the two-step reaction has the potential to be cost-competitive with the process based on single-step supercritical transesterification. Higher biodiesel yields, similar or lower energy

  18. Dysphagia is prevalent in patients with CPEO and single, large-scale deletions in mtDNA

    DEFF Research Database (Denmark)

    Pedersen, Gitte Hedermann; Løkken, Nicoline; Dahlqvist, Julia R.

    2017-01-01

    Background  The aim of this study was to assess the frequency of subjective and objective dysphagia in patients with chronic progressive external ophthalmoplegia (CPEO) due to single, large-scale deletions (LSDs) of mitochondrial DNA (mtDNA). Methods  Sixteen patients with CPEO and single LSDs...... and single LSDs of mtDNA had a prolonged cold-water test, including one with a PEG-tube, who was unable to perform the test, and nine patients reported subjective swallowing problems (56.3%). All mitochondrial myopathy patients in the control group had a normal duration of the cold-water test.  Conclusions......  The study shows that dysphagia is a common problem in patients with CPEO and LSDs of mtDNA. Dysphagia seems to be progressive with age as abnormal swallowing occurred preferentially in persons ≥ 45 years. The study shows that increased awareness of this symptom should be given to address appropriate...

  19. Assessing Health Status in Inflammatory Bowel Disease using a Novel Single-Item Numeric Rating Scale

    Science.gov (United States)

    Surti, Bijal; Spiegel, Brennan; Ippoliti, Andrew; Vasiliauskas, Eric; Simpson, Peter; Shih, David; Targan, Stephan; McGovern, Dermot; Melmed, Gil Y.

    2014-01-01

    Background Current instruments used to measure disease activity and health-related quality of life (HRQOL) in patients with Crohn’s disease (CD) and ulcerative colitis (UC) are often cumbersome, time-consuming, and expensive; although used in clinical trials, they are not convenient for clinical practice. A numeric rating scale (NRS) is a quick, inexpensive, and convenient patient-reported outcome (PRO) that can capture the patient’s overall perception of health. Aims To assess the validity, reliability, and responsiveness of an NRS and evaluate its use in clinical practice in patients with CD and UC. Methods We prospectively evaluated patient-reported NRS scores and measured correlations between NRS and a range of severity measures, including physician-reported NRS, Crohn’s disease activity index (CDAI), Harvey-Bradshaw index (HBI), inflammatory bowel disease questionnaire (IBDQ), and C-reactive protein (CRP) in patients with CD. Subsequently, we evaluated the correlation between the NRS and standard measures of health status (HBI or simple colitis clinical activity index [SCCAI]) and laboratory tests (sedimentation rate [ESR], CRP, and fecal calprotectin) in patients with CD and UC. Results The patient-reported NRS showed excellent correlation with CDAI (R2=0.59, p<0.0001), IBDQ (R2=0.66, p<0.0001), and HBI (R2=0.32, p<0.0001) in patients with CD. The NRS showed poor, but statistically significant correlation with SCCAI (R2=0.25, p<0.0001) in patients with UC. The NRS did not correlate with CRP, ESR, or calprotectin. The NRS was reliable and responsive to change. Conclusions The NRS is a valid, reliable, and responsive measure that may be useful to evaluate patients with CD and possibly UC. PMID:23250673

  20. Immunohistochemical subtypes predict the clinical outcome in high-risk node-negative breast cancer patients treated with adjuvant FEC regimen: results of a single-center retrospective study

    International Nuclear Information System (INIS)

    Rahal, S.; Boher, J M; Extra, J M; Tarpin, C.; Charafe-Jauffret, E.; Lambaudie, E.; Sabatier, R.; Thomassin-Piana, J.; Tallet, A.; Resbeut, M.; Houvenaeghel, G.; Laborde, L.; Bertucci, F.; Viens, P.; Gonçalves, A.

    2015-01-01

    Anthracycline-based adjuvant chemotherapy improves survival in patients with high-risk node-negative breast cancer (BC). In this setting, prognostic factors predicting for treatment failure might help selecting among the different available cytotoxic combinations. Between 1998 and 2008, 757 consecutive patients with node-negative BC treated in our institution with adjuvant FEC (5FU, epirubicin, cyclophosphamide) chemotherapy were identified. Data collection included demographic, clinico-pathological characteristics and treatment information. Molecular subtypes were derived from estrogen receptor (ER), progesterone receptor (PR), human epidermal growth factor receptor 2 (HER2) status and Scarff-Bloom-Richardson (SBR) grade. Disease-free survival (DFS), distant disease-free survival (DDFS) and overall survival (OS) were estimated using the Kaplan-Meier Method, and prognostic factors were examined by multivariate Cox analysis. After a median follow-up of 70 months, the 5-year DFS, DDFS and OS were 90.6 % (95 % confidence interval (CI): 88.2–93.1), 92.8 % (95 % CI: 90.7–95) and 95.1 % (95 % CI, 93.3–96.9), respectively. In the multivariate analysis including classical clinico-pathological parameters, only grade 3 maintained a significant and independent adverse prognostic impact. In an alternative multivariate model where ER, PR and grade were replaced by molecular subtypes, only luminal B/HER2-negative and triple-negative subtypes were associated with reduced DFS and DDFS. Node-negative BC patients receiving adjuvant FEC regimen have a favorable outcome. Luminal B/HER2-negative and triple-negative subtypes identify patients with a higher risk of treatment failure, which might warrant more aggressive systemic treatment. The online version of this article (doi:10.1186/s12885-015-1746-3) contains supplementary material, which is available to authorized users

  1. An alternative to the search for single polymorphisms: toward molecular personality scales for the five-factor model.

    Science.gov (United States)

    McCrae, Robert R; Scally, Matthew; Terracciano, Antonio; Abecasis, Gonçalo R; Costa, Paul T

    2010-12-01

    There is growing evidence that personality traits are affected by many genes, all of which have very small effects. As an alternative to the largely unsuccessful search for individual polymorphisms associated with personality traits, the authors identified large sets of potentially related single nucleotide polymorphisms (SNPs) and summed them to form molecular personality scales (MPSs) with from 4 to 2,497 SNPs. Scales were derived from two thirds of a large (N = 3,972) sample of individuals from Sardinia who completed the Revised NEO Personality Inventory (P. T. Costa, Jr., & R. R. McCrae, 1992) and were assessed in a genomewide association scan. When MPSs were correlated with the phenotype in the remaining one third of the sample, very small but significant associations were found for 4 of the 5e personality factors when the longest scales were examined. These data suggest that MPSs for Neuroticism, Openness to Experience, Agreeableness, and Conscientiousness (but not Extraversion) contain genetic information that can be refined in future studies, and the procedures described here should be applicable to other quantitative traits. PsycINFO Database Record (c) 2010 APA, all rights reserved.

  2. Sentinel lymph node biopsy is indicated for patients with thick clinically lymph node-negative melanoma.

    Science.gov (United States)

    Yamamoto, Maki; Fisher, Kate J; Wong, Joyce Y; Koscso, Jonathan M; Konstantinovic, Monique A; Govsyeyev, Nicholas; Messina, Jane L; Sarnaik, Amod A; Cruse, C Wayne; Gonzalez, Ricardo J; Sondak, Vernon K; Zager, Jonathan S

    2015-05-15

    Sentinel lymph node biopsy (SLNB) is indicated for the staging of clinically lymph node-negative melanoma of intermediate thickness, but its use is controversial in patients with thick melanoma. From 2002 to 2012, patients with melanoma measuring ≥4 mm in thickness were evaluated at a single institution. Associations between survival and clinicopathologic characteristics were explored. Of 571 patients with melanomas measuring ≥4 mm in thickness and no distant metastases, the median age was 66 years and 401 patients (70.2%) were male. The median Breslow thickness was 6.2 mm; the predominant subtype was nodular (45.4%). SLNB was performed in 412 patients (72%) whereas 46 patients (8.1%) presented with clinically lymph node-positive disease and 113 patients (20%) did not undergo SLNB. A positive SLN was found in 161 of 412 patients (39.1%). For SLNB performed at the study institution, 14 patients with a negative SLNB developed disease recurrence in the mapped lymph node basin (false-negative rate, 12.3%). The median disease-specific survival (DSS), overall survival (OS), and recurrence-free survival (RFS) for the entire cohort were 62.1 months, 42.5 months, and 21.2 months, respectively. The DSS and OS for patients with a negative SLNB were 82.4 months and 53.4 months, respectively; 41.2 months and 34.7 months, respectively, for patients with positive SLNB; and 26.8 months and 22 months, respectively, for patients with clinically lymph node-positive disease (Pthick melanoma and a negative SLNB appear to have significantly prolonged RFS, DSS, and OS compared with those with a positive SLNB. Therefore, SLNB should be considered as indicated for patients with thick, clinically lymph node-negative melanoma. © 2015 American Cancer Society.

  3. Max-Min SINR in Large-Scale Single-Cell MU-MIMO: Asymptotic Analysis and Low Complexity Transceivers

    KAUST Repository

    Sifaou, Houssem

    2016-12-28

    This work focuses on the downlink and uplink of large-scale single-cell MU-MIMO systems in which the base station (BS) endowed with M antennas communicates with K single-antenna user equipments (UEs). Particularly, we aim at reducing the complexity of the linear precoder and receiver that maximize the minimum signal-to-interference-plus-noise ratio subject to a given power constraint. To this end, we consider the asymptotic regime in which M and K grow large with a given ratio. Tools from random matrix theory (RMT) are then used to compute, in closed form, accurate approximations for the parameters of the optimal precoder and receiver, when imperfect channel state information (modeled by the generic Gauss-Markov formulation form) is available at the BS. The asymptotic analysis allows us to derive the asymptotically optimal linear precoder and receiver that are characterized by a lower complexity (due to the dependence on the large scale components of the channel) and, possibly, by a better resilience to imperfect channel state information. However, the implementation of both is still challenging as it requires fast inversions of large matrices in every coherence period. To overcome this issue, we apply the truncated polynomial expansion (TPE) technique to the precoding and receiving vector of each UE and make use of RMT to determine the optimal weighting coefficients on a per- UE basis that asymptotically solve the max-min SINR problem. Numerical results are used to validate the asymptotic analysis in the finite system regime and to show that the proposed TPE transceivers efficiently mimic the optimal ones, while requiring much lower computational complexity.

  4. Final report for the mobile node authentication LDRD project.

    Energy Technology Data Exchange (ETDEWEB)

    Michalski, John T.; Lanzone, Andrew J.

    2005-09-01

    In hostile ad hoc wireless communication environments, such as battlefield networks, end-node authentication is critical. In a wired infrastructure, this authentication service is typically facilitated by a centrally-located ''authentication certificate generator'' such as a Certificate Authority (CA) server. This centralized approach is ill-suited to meet the needs of mobile ad hoc networks, such as those required by military systems, because of the unpredictable connectivity and dynamic routing. There is a need for a secure and robust approach to mobile node authentication. Current mechanisms either assign a pre-shared key (shared by all participating parties) or require that each node retain a collection of individual keys that are used to communicate with other individual nodes. Both of these approaches have scalability issues and allow a single compromised node to jeopardize the entire mobile node community. In this report, we propose replacing the centralized CA with a distributed CA whose responsibilities are shared between a set of select network nodes. To that end, we develop a protocol that relies on threshold cryptography to perform the fundamental CA duties in a distributed fashion. The protocol is meticulously defined and is implemented it in a series of detailed models. Using these models, mobile wireless scenarios were created on a communication simulator to test the protocol in an operational environment and to gather statistics on its scalability and performance.

  5. Identifying key nodes in multilayer networks based on tensor decomposition.

    Science.gov (United States)

    Wang, Dingjie; Wang, Haitao; Zou, Xiufen

    2017-06-01

    The identification of essential agents in multilayer networks characterized by different types of interactions is a crucial and challenging topic, one that is essential for understanding the topological structure and dynamic processes of multilayer networks. In this paper, we use the fourth-order tensor to represent multilayer networks and propose a novel method to identify essential nodes based on CANDECOMP/PARAFAC (CP) tensor decomposition, referred to as the EDCPTD centrality. This method is based on the perspective of multilayer networked structures, which integrate the information of edges among nodes and links between different layers to quantify the importance of nodes in multilayer networks. Three real-world multilayer biological networks are used to evaluate the performance of the EDCPTD centrality. The bar chart and ROC curves of these multilayer networks indicate that the proposed approach is a good alternative index to identify real important nodes. Meanwhile, by comparing the behavior of both the proposed method and the aggregated single-layer methods, we demonstrate that neglecting the multiple relationships between nodes may lead to incorrect identification of the most versatile nodes. Furthermore, the Gene Ontology functional annotation demonstrates that the identified top nodes based on the proposed approach play a significant role in many vital biological processes. Finally, we have implemented many centrality methods of multilayer networks (including our method and the published methods) and created a visual software based on the MATLAB GUI, called ENMNFinder, which can be used by other researchers.

  6. Feasibility of sentinel node lymphoscintigraphy in stage I testicular cancer

    Energy Technology Data Exchange (ETDEWEB)

    Tanis, Pieter J.; Nieweg, Omgo E. [Department of Surgery, Netherlands Cancer Institute, Amsterdam (Netherlands); Horenblas, Simon [Department of Urology, Netherlands Cancer Institute, Amsterdam (Netherlands); Olmos, Renato Valdes A.; Hoefnagel, Cornelis A. [Department of Nuclear Medicine, The Netherlands Cancer Institute, Amsterdam (Netherlands)

    2002-05-01

    The aim of this study was to investigate the feasibility of lymphoscintigraphy for sentinel node identification in testicular cancer. Five patients with clinical stage I testicular cancer were prospectively included. A single dose of technetium-99m nanocolloid (mean dose 99 MBq, volume 0.2 ml) was injected into the funiculus in the first patient and into the testicular parenchyma in the following four patients. Dynamic lymphoscintigraphy was performed over 10 min, followed by early and late static images after 15 min and 2 to 24 h, respectively. Lymphoscintigraphy was followed by laparoscopic sentinel node biopsy on the same day in the last two patients using patent blue dye and an endoscopic gamma probe. The funicular administration route showed five hot spots in the right inguinal region after 2 h. Intratesticular administration resulted in sentinel node visualisation in three of the four patients. Dynamic images showed afferent lymphatic vessels to one sentinel node in the left para-aortic region in two patients and two sentinel nodes in the left para-aortic region in another patient. Sentinel nodes were intraoperatively identified in one of two patients who underwent laparoscopic exploration. It is concluded that lymphoscintigraphy for sentinel node identification is feasible in stage I testicular cancer using intratesticular radiocolloid administration. (orig.)

  7. Mirror node correlations tuning synchronization in multiplex networks

    Science.gov (United States)

    Kumar, Anil; Baptista, Murilo S.; Zaikin, Alexey; Jalan, Sarika

    2017-12-01

    We show that the degree-degree correlations have a major impact on global synchronizability (GS) of multiplex networks, enabling the specification of synchronizability by only changing the degree-degree correlations of the mirror nodes while maintaining the connection architecture of the individual layer unaltered. If individual layers have nodes that are mildly correlated, the multiplex network is best synchronizable when the mirror degrees are strongly negatively correlated. If individual layers have nodes with strong degree-degree correlations, mild correlations among the degrees of mirror nodes are the best strategy for the optimization of GS. Global synchronization also depend on the density of connections, a phenomenon not observed in a single layer network. The results are crucial to understand, predict, and specify behavior of systems having multiple types of connections among the interacting units.

  8. Imaging Live Cells at the Nanometer-Scale with Single-Molecule Microscopy: Obstacles and Achievements in Experiment Optimization for Microbiology

    Science.gov (United States)

    Haas, Beth L.; Matson, Jyl S.; DiRita, Victor J.; Biteen, Julie S.

    2015-01-01

    Single-molecule fluorescence microscopy enables biological investigations inside living cells to achieve millisecond- and nanometer-scale resolution. Although single-molecule-based methods are becoming increasingly accessible to non-experts, optimizing new single-molecule experiments can be challenging, in particular when super-resolution imaging and tracking are applied to live cells. In this review, we summarize common obstacles to live-cell single-molecule microscopy and describe the methods we have developed and applied to overcome these challenges in live bacteria. We examine the choice of fluorophore and labeling scheme, approaches to achieving single-molecule levels of fluorescence, considerations for maintaining cell viability, and strategies for detecting single-molecule signals in the presence of noise and sample drift. We also discuss methods for analyzing single-molecule trajectories and the challenges presented by the finite size of a bacterial cell and the curvature of the bacterial membrane. PMID:25123183

  9. A local-world node deleting evolving network model

    International Nuclear Information System (INIS)

    Gu Yuying; Sun Jitao

    2008-01-01

    A new type network growth rule which comprises node addition with the concept of local-world connectivity and node deleting is studied. A series of theoretical analysis and numerical simulation to the LWD network are conducted in this Letter. Firstly, the degree distribution p(k) of this network changes no longer pure scale free but truncates by an exponential tail and the truncation in p(k) increases as p a decreases. Secondly, the connectivity is tighter, as the local-world size M increases. Thirdly, the average path length L increases and the clustering coefficient decreases as generally node deleting increases. Finally, trends up when the local-world size M increases, so as to k max . Hence, the expanding local-world can compensate the infection of the node deleting

  10. A local-world node deleting evolving network model

    Energy Technology Data Exchange (ETDEWEB)

    Gu Yuying [Department of Mathematics, Tongji University, Shanghai 200092 (China); Sun Jitao [Department of Mathematics, Tongji University, Shanghai 200092 (China)], E-mail: sunjt@sh163.net

    2008-06-16

    A new type network growth rule which comprises node addition with the concept of local-world connectivity and node deleting is studied. A series of theoretical analysis and numerical simulation to the LWD network are conducted in this Letter. Firstly, the degree distribution p(k) of this network changes no longer pure scale free but truncates by an exponential tail and the truncation in p(k) increases as p{sub a} decreases. Secondly, the connectivity is tighter, as the local-world size M increases. Thirdly, the average path length L increases and the clustering coefficient decreases as generally node deleting increases. Finally, trends up when the local-world size M increases, so as to k{sub max}. Hence, the expanding local-world can compensate the infection of the node deleting.

  11. Information loss method to measure node similarity in networks

    Science.gov (United States)

    Li, Yongli; Luo, Peng; Wu, Chong

    2014-09-01

    Similarity measurement for the network node has been paid increasing attention in the field of statistical physics. In this paper, we propose an entropy-based information loss method to measure the node similarity. The whole model is established based on this idea that less information loss is caused by seeing two more similar nodes as the same. The proposed new method has relatively low algorithm complexity, making it less time-consuming and more efficient to deal with the large scale real-world network. In order to clarify its availability and accuracy, this new approach was compared with some other selected approaches on two artificial examples and synthetic networks. Furthermore, the proposed method is also successfully applied to predict the network evolution and predict the unknown nodes' attributions in the two application examples.

  12. Multi-scale Mexican spotted owl (Strix occidentalis lucida) nest/roost habitat selection in Arizona and a comparison with single-scale modeling results

    Science.gov (United States)

    Brad C. Timm; Kevin McGarigal; Samuel A. Cushman; Joseph L. Ganey

    2016-01-01

    Efficacy of future habitat selection studies will benefit by taking a multi-scale approach. In addition to potentially providing increased explanatory power and predictive capacity, multi-scale habitat models enhance our understanding of the scales at which species respond to their environment, which is critical knowledge required to implement effective...

  13. Comparison of children versus adults undergoing mini-percutaneous nephrolithotomy: large-scale analysis of a single institution.

    Directory of Open Access Journals (Sweden)

    Guohua Zeng

    Full Text Available OBJECTIVE: As almost any version of percutaneous nephrolithotomy (PCNL was safely and efficiently applied for adults as well as children without age being a limiting risk factor, the aim of the study was to compare the different characteristics as well as the efficacy, outcome, and safety of the pediatric and adult patients who had undergone mini-PCNL (MPCNL in a single institution. METHODS: We retrospective reviewed 331 renal units in children and 8537 renal units in adults that had undergone MPCNL for upper urinary tract stones between the years of 2000-2012. The safety, efficacy, and outcome were analyzed and compared. RESULTS: The children had a smaller stone size (2.3 vs. 3.1 cm but had smilar stone distribution (number and locations. The children required fewer percutaneous accesses, smaller nephrostomy tract, shorter operative time and less hemoglobin drop. The children also had higher initial stone free rate (SFR (80.4% vs. 78.6% after single session of MPCNL (p0.05. Both groups had low rate of high grade Clavien complications. There was no grade III, IV, V complications and no angiographic embolization required in pediatric group. One important caveat, children who required multiple percutaneous nephrostomy tracts had significant higher transfusion rate than in adults (18.8% vs. 4.5%, p = 0.007. CONCLUSIONS: This contemporary largest-scale analysis confirms that the stone-free rate in pediatric patients is at least as good as in adults without an increase of complication rates. However, multiple percutaneous nephrostomy tracts should be practiced with caution in children.

  14. Comparison of mediastinal lymph node status and relapse pattern in clinical stage IIIA non-small cell lung cancer patients treated with neoadjuvant chemotherapy versus upfront surgery: A single center experience.

    Science.gov (United States)

    Savic, Milan; Kontic, Milica; Ercegovac, Maja; Stojsic, Jelena; Bascarevic, Slavisa; Moskovljevic, Dejan; Kostic, Marko; Vesovic, Radomir; Popevic, Spasoje; Laban, Marija; Markovic, Jelena; Jovanovic, Dragana

    2017-09-01

    In spite of the progress made in neoadjuvant therapy for operable non small-cell lung cancer (NSCLC), many issues remain unsolved, especially in locally advanced stage IIIA. Retrospective data of 163 patients diagnosed with stage IIIA NSCLC after surgery was analyzed. The patients were divided into two groups: a preoperative chemotherapy group including 59 patients who received platinum-etoposide doublet treatment before surgery, and an upfront surgery group including 104 patients for whom surgical resection was the first treatment step. Adjuvant chemotherapy or/and radiotherapy was administered to 139 patients (85.3%), while 24 patients (14.7%) were followed-up only. The rate of N2 disease was significantly higher in the upfront surgery group ( P   0.05). There was significant difference in preoperative chemotherapy group regarding relapse rate and treatment outcomes related to the lymph node status comparing to the upfront surgery group. Neoadjuvant/adjuvant chemo-therapy is a part of treatment for patients with stage IIIA NSCLC, but further investigation is required to determine optimal treatment. © 2017 The Authors. Thoracic Cancer published by China Lung Oncology Group and John Wiley & Sons Australia, Ltd.

  15. Improvement of the SEP protocol based on community structure of node degree

    Science.gov (United States)

    Li, Donglin; Wei, Suyuan

    2017-05-01

    Analyzing the Stable election protocol (SEP) in wireless sensor networks and aiming at the problem of inhomogeneous cluster-heads distribution and unreasonable cluster-heads selectivity and single hop transmission in the SEP, a SEP Protocol based on community structure of node degree (SEP-CSND) is proposed. In this algorithm, network node deployed by using grid deployment model, and the connection between nodes established by setting up the communication threshold. The community structure constructed by node degree, then cluster head is elected in the community structure. On the basis of SEP, the node's residual energy and node degree is added in cluster-heads election. The information is transmitted with mode of multiple hops between network nodes. The simulation experiments showed that compared to the classical LEACH and SEP, this algorithm balances the energy consumption of the entire network and significantly prolongs network lifetime.

  16. Criticality predicts maximum irregularity in recurrent networks of excitatory nodes.

    Directory of Open Access Journals (Sweden)

    Yahya Karimipanah

    Full Text Available A rigorous understanding of brain dynamics and function requires a conceptual bridge between multiple levels of organization, including neural spiking and network-level population activity. Mounting evidence suggests that neural networks of cerebral cortex operate at a critical regime, which is defined as a transition point between two phases of short lasting and chaotic activity. However, despite the fact that criticality brings about certain functional advantages for information processing, its supporting evidence is still far from conclusive, as it has been mostly based on power law scaling of size and durations of cascades of activity. Moreover, to what degree such hypothesis could explain some fundamental features of neural activity is still largely unknown. One of the most prevalent features of cortical activity in vivo is known to be spike irregularity of spike trains, which is measured in terms of the coefficient of variation (CV larger than one. Here, using a minimal computational model of excitatory nodes, we show that irregular spiking (CV > 1 naturally emerges in a recurrent network operating at criticality. More importantly, we show that even at the presence of other sources of spike irregularity, being at criticality maximizes the mean coefficient of variation of neurons, thereby maximizing their spike irregularity. Furthermore, we also show that such a maximized irregularity results in maximum correlation between neuronal firing rates and their corresponding spike irregularity (measured in terms of CV. On the one hand, using a model in the universality class of directed percolation, we propose new hallmarks of criticality at single-unit level, which could be applicable to any network of excitable nodes. On the other hand, given the controversy of the neural criticality hypothesis, we discuss the limitation of this approach to neural systems and to what degree they support the criticality hypothesis in real neural networks. Finally

  17. Delineation of the geometry of the nodes in the Alps-Dinarides hinge zone and recognition of seismogenic nodes (M ≥ 6)

    International Nuclear Information System (INIS)

    Gorshkov, A.I.; Soloviev, A.A.; Panza, G.F.; Aoudia, A.; Peresan, A.

    2007-11-01

    In the junction zone between the Alps and the Dinarides, one of the most seismically active areas in Europe, we delineate a total of sixteen nodes which are capable of M ≥ 6.0 earthquakes using large-scale cartographic data. Seven of them have already experienced the occurrence of sufficiently well located earthquakes with M ≥ 6.0. Using these seven nodes as a learning set, we identify, by means of the pattern recognition methodology, three other nodes prone to earthquakes with M ≥ 6.0: one node in the Alpine domain and two in the northernmost Dinarides. (author)

  18. Differentiation of Metastatic and Non-Metastatic Mesenteric Lymph Nodes by Strain Elastography in Surgical Specimens

    DEFF Research Database (Denmark)

    Havre, R F; Leh, S M; Gilja, O H

    2016-01-01

    Purpose: To investigate if strain elastography could differentiate between metastatic and non-metastatic mesenteric lymph nodes ex-vivo. Materials and Methods: 90 mesenteric lymph nodes were examined shortly after resection from 25 patients including 17 patients with colorectal cancer and 8...... patients with Crohn's disease. Ultrasound-based strain elastography was performed with a linear probe. Tissue hardness in lymph nodes was assessed using visual scales and measuring the strain ratio. B-mode characteristics were also recorded. Pathological diagnosis with grading of fibrosis served...... non-metastatic nodes, but the difference was not significant (65.5 vs. 55.0, p = 0.055). There was no difference between lymph nodes in Crohn's and non-metastatic cancer specimens. The metastatic lymph nodes were significantly more fibrotic than the non-metastatic lymph nodes by the ordinal fibrosis...

  19. Large-scale preparation of CdS quantum dots by direct thermolysis of a single-source precursor

    Energy Technology Data Exchange (ETDEWEB)

    Li Zhiguo; Cai Wei; Sui Jiehe [School of Material Science and Engineering, Harbin Institute of Technology, Harbin, Heilongjiang 150001 (China)

    2008-01-23

    CdS quantum dots (QDs) have been synthesized on a large scale, based on the direct thermolysis of one single-source precursor (Me{sub 4}N){sub 4}[S{sub 4}Cd{sub 10}(SPh){sub 16}], in hexadecylamine (HDA). Transmission electron microscopy (TEM) observations show that the CdS QDs are well-defined, nearly spherical particles. The clear lattice fringes in high-resolution TEM (HRTEM) images confirm the crystalline nature of the QDs. The broad diffraction in the x-ray diffraction (XRD) pattern and diffuse diffraction rings of the selected-area electron diffraction (SAED) pattern are typical of nanomeric-size particles and indicative of the hexagonal phase of CdS QDs. The absorption spectra confirm quantum confinement of CdS QDs. The synthesis process for CdS QDs was investigated by ultraviolet-visible (UV-vis) absorption spectroscopy. The results demonstrate that the nucleation and growth stages were separated automatically in a homogeneous system.

  20. Intraoperative Sentinel Lymph Node Evaluation

    DEFF Research Database (Denmark)

    Shaw, Richard; Christensen, Anders; Java, Kapil

    2016-01-01

    BACKGROUND: Intraoperative analysis of sentinel lymph nodes would enhance the care of early-stage oral squamous cell carcinoma (OSCC). We determined the frequency and extent of cytokeratin 19 (CK19) expression in OSCC primary tumours and surrounding tissues to explore the feasibility of a "clinic......-ready" intraoperative diagnostic test (one step nucleic acid amplification-OSNA, sysmex). METHODS: Two cohorts were assembled: cohort 1, OSCC with stage and site that closely match cases suitable for sentinel lymph node biopsy (SLNB); cohort 2, HNSCC with sufficient fresh tumour tissue available for the OSNA assay (>50......% of tumours. Discordance between different techniques indicated that OSNA was more sensitive than qRT-PCR or RNA-ISH, which in turn were more sensitive than IHC. OSNA results showed CK19 expression in 80% of primary cases, so if used for diagnosis of lymph node metastasis would lead to a false-negative result...

  1. Methodology of sentinel node detection

    International Nuclear Information System (INIS)

    Maublant, J.

    2000-01-01

    The isotopic localisation of the sentinel node, i.e., the first functional lymph node in a tumor basin, is probably the fastest growing field ever experienced in nuclear medicine. Although based on the simple concept of the lymphatic migration of Tc-labeled colloids, the choice of the optimal technique remains controversial. We review and discuss the role of the colloids, of the site of injection, of the injected volume, of early imaging and of the colorimetric approach. Initially applied to melanoma and breast cancer, the sentinel node detection is now tested in other types of cancer such as lung, colon and prostate. It could become one of the leading tools in minimally invasive surgical oncology. The nuclear medicine physician has to remain aware of the rapid evolutions in this field in order to be able to answer to a rapidly growing demand. (author)

  2. Energy and Delay Optimization of Heterogeneous Multicore Wireless Multimedia Sensor Nodes by Adaptive Genetic-Simulated Annealing Algorithm

    Directory of Open Access Journals (Sweden)

    Xing Liu

    2018-01-01

    Full Text Available Energy efficiency and delay optimization are significant for the proliferation of wireless multimedia sensor network (WMSN. In this article, an energy-efficient, delay-efficient, hardware and software cooptimization platform is researched to minimize the energy cost while guaranteeing the deadline of the real-time WMSN tasks. First, a multicore reconfigurable WMSN hardware platform is designed and implemented. This platform uses both the heterogeneous multicore architecture and the dynamic voltage and frequency scaling (DVFS technique. By this means, the nodes can adjust the hardware characteristics dynamically in terms of the software run-time contexts. Consequently, the software can be executed more efficiently with less energy cost and shorter execution time. Then, based on this hardware platform, an energy and delay multiobjective optimization algorithm and a DVFS adaption algorithm are investigated. These algorithms aim to search out the global energy optimization solution within the acceptable calculation time and strip the time redundancy in the task executing process. Thus, the energy efficiency of the WMSN node can be improved significantly even under strict constraint of the execution time. Simulation and real-world experiments proved that the proposed approaches can decrease the energy cost by more than 29% compared to the traditional single-core WMSN node. Moreover, the node can react quickly to the time-sensitive events.

  3. The composing technique of fast and large scale nuclear data acquisition and control system with single chip microcomputers and PC computers

    International Nuclear Information System (INIS)

    Xu Zurun; Wu Shiying; Liu Haitao; Yao Yangsen; Wang Yingguan; Yang Chaowen

    1998-01-01

    The technique of employing single-chip microcomputers and PC computers to compose a fast and large scale nuclear data acquisition and control system was discussed in detail. The optimum composition mode of this kind of system, the acquisition and control circuit unit based on single-chip microcomputers, the real-time communication methods and the software composition under the Windows 3.2 were also described. One, two and three dimensional spectra measured by this system were demonstrated

  4. The composing technique of fast and large scale nuclear data acquisition and control system with single chip microcomputers and PC computers

    International Nuclear Information System (INIS)

    Xu Zurun; Wu Shiying; Liu Haitao; Yao Yangsen; Wang Yingguan; Yang Chaowen

    1997-01-01

    The technique of employing single-chip microcomputers and PC computers to compose a fast and large scale nuclear data acquisition and control system was discussed in detail. The optimum composition mode of this kind of system, the acquisition and control circuit unit based on single-chip microcomputers, the real-time communication methods and the software composition under the Windows 3.2 were also described. One, two and three dimensional spectra measured by this system were demonstrated

  5. Using Link Disconnection Entropy Disorder to Detect Fast Moving Nodes in MANETs.

    Science.gov (United States)

    Alvarez, Carlos F; Palafox, Luis E; Aguilar, Leocundo; Sanchez, Mauricio A; Martinez, Luis G

    2016-01-01

    Mobile ad-hoc networks (MANETs) are dynamic by nature; this dynamism comes from node mobility, traffic congestion, and other transmission conditions. Metrics to evaluate the effects of those conditions shine a light on node's behavior in an ad-hoc network, helping to identify the node or nodes with better conditions of connection. In this paper, we propose a relative index to evaluate a single node reliability, based on the link disconnection entropy disorder using neighboring nodes as reference. Link disconnection entropy disorder is best used to identify fast moving nodes or nodes with unstable communications, this without the need of specialized sensors such as GPS. Several scenarios were studied to verify the index, measuring the effects of Speed and traffic density on the link disconnection entropy disorder. Packet delivery ratio is associated to the metric detecting a strong relationship, enabling the use of the link disconnection entropy disorder to evaluate the stability of a node to communicate with other nodes. To expand the utilization of the link entropy disorder, we identified nodes with higher speeds in network simulations just by using the link entropy disorder.

  6. Allocating resources between network nodes for providing a network node function

    NARCIS (Netherlands)

    Strijkers, R.J.; Meulenhoff, P.J.

    2014-01-01

    The invention provides a method wherein a first network node advertises available resources that a second network node may use to offload network node functions transparently to the first network node. Examples of the first network node are a client device (e.g. PC, notebook, tablet, smart phone), a

  7. Need for High Radiation Dose (≥70 Gy) in Early Postoperative Irradiation After Radical Prostatectomy: A Single-Institution Analysis of 334 High-Risk, Node-Negative Patients

    International Nuclear Information System (INIS)

    Cozzarini, Cesare; Montorsi, Francesco; Fiorino, Claudio; Alongi, Filippo; Bolognesi, Angelo; Da Pozzo, Luigi Filippo; Guazzoni, Giorgio; Freschi, Massimo; Roscigno, Marco; Scattoni, Vincenzo; Rigatti, Patrizio; Di Muzio, Nadia

    2009-01-01

    Purpose: To determine the clinical benefit of high-dose early adjuvant radiotherapy (EART) in high-risk prostate cancer (hrCaP) patients submitted to radical retropubic prostatectomy plus pelvic lymphadenectomy. Patients and Methods: The clinical outcome of 334 hrCaP (pT3-4 and/or positive resection margins) node-negative patients submitted to radical retropubic prostatectomy plus pelvic lymphadenectomy before 2004 was analyzed according to the EART dose delivered to the prostatic bed, <70.2 Gy (lower dose, median 66.6 Gy, n = 153) or ≥70.2 Gy (median 70.2 Gy, n = 181). Results: The two groups were comparable except for a significant difference in terms of median follow-up (10 vs. 7 years, respectively) owing to the gradual increase of EART doses over time. Nevertheless, median time to prostate-specific antigen (PSA) failure was almost identical, 38 and 36 months, respectively. At univariate analysis, both 5-year biochemical relapse-free survival (bRFS) and disease-free survival (DFS) were significantly higher (83% vs. 71% [p = 0.001] and 94% vs. 88% [p = 0.005], respectively) in the HD group. Multivariate analysis confirmed EART dose ≥70 Gy to be independently related to both bRFS (hazard ratio 2.5, p = 0.04) and DFS (hazard ratio 3.6, p = 0.004). Similar results were obtained after the exclusion of patients receiving any androgen deprivation. After grouping the hormone-naive patients by postoperative PSA level the statistically significant impact of high-dose EART on both 5-year bRFS and DFS was maintained only for those with undetectable values, possibly owing to micrometastatic disease outside the irradiated area in case of detectable postoperative PSA values. Conclusion: This series provides strong support for the use of EART doses ≥70 Gy after radical retropubic prostatectomy in hrCaP patients with undetectable postoperative PSA levels.

  8. Does the atrioventricular node conduct?

    NARCIS (Netherlands)

    Meijler, F.L.; Fisch, C.

    1989-01-01

    It is difficult to be certain wh en the term "conduction" was first applied to the transfer of atrial activation to the ventricles .' In 1894, Engelmann used the word "Leitung", which can be translated as "connection" or as "conduction" .2 In 1906, Tawara described the atrioventricular node,

  9. Node.js by example

    CERN Document Server

    Tsonev, Krasimir

    2015-01-01

    If you are a JavaScript developer with no experience with Node.js or server-side web development, this book is for you. It will lead you through creating a fairly complex social network. You will learn how to work with a database and create real-time communication channels.

  10. Smart Home Wireless Sensor Nodes

    DEFF Research Database (Denmark)

    Lynggaard, Per

    . This paper introduces an approach that considerably lowers the wireless sensor node power consumption and the amount of transmitted sensor events. It uses smart objects that include artificial intelligence to efficiently process the sensor event on location and thereby saves the costly wireless...

  11. Critical nodes in signalling pathways

    DEFF Research Database (Denmark)

    Taniguchi, Cullen M; Emanuelli, Brice; Kahn, C Ronald

    2006-01-01

    Physiologically important cell-signalling networks are complex, and contain several points of regulation, signal divergence and crosstalk with other signalling cascades. Here, we use the concept of 'critical nodes' to define the important junctions in these pathways and illustrate their unique role...... using insulin signalling as a model system....

  12. Elemental and Isotopic Tomography at Single-Atom-Scale in 4.0 and 2.4 Ga Zircons

    Science.gov (United States)

    Valley, J. W.; Reinhard, D. A.; Snoeyenbos, D.; Lawrence, D.; Martin, I.; Kelly, T. F.; Ushikubo, T.; Strickland, A.; Cavosie, A. J.

    2012-12-01

    Atom probe tomography can determine identity (mass/charge ratio) and 3-D position of individual atoms in minerals such as zircon. These data provide unique information for understanding the thermal history and mechanisms of mineral reaction and exchange, including radiation damage. Nine needle-shaped specimens ~100 nm in diameter (at the apex) were sampled from 2 zircons by FIB and analyzed with a local-electrode atom probe (LEAP), CAMECA LEAP 4000X HR. The LEAP uses pulsed-laser heating to field evaporate the tip of a zircon needle and accelerates the ions into a position-sensitive TOF-MS. With due care for complex isobaric interferences (molecules, multiple ionizations) and background correction, it is possible to individually identify up to 10E8 atoms/needle (36% detection efficiency) by mass/charge (MRP ~ 1000@ m/n=16Da) and position (X-Y-Z coordinates on 0.2 nm scale) (Kelly & Larson 2012). The 3-D distribution of Pb and Y differ at atom-scale in the 2 zircons. Zircon #1 (4007 Ma, Jack Hills, W. Australia, Cavosie 2005, Ushikubo et al. 2008, Bouvier et al. 2011) is homogeneous in Pb and Y. In contrast, incompatible elements, including Pb and Y, are concentrated in equant 5-10 nm dia. domains, spaced ~50 nm apart in zircon #2 (2438 Ma, Albion-Raft R-Grouse Ck core complex, Utah, Strickland et al. 2011). U is homogeneously distributed in both zircons. The analyzed domains suffered 4-8 x 10E15 α-decay events/mg due to U and Th decay and yet both zircons yield >97% concordant U-Pb ages by SIMS, suggesting annealing of radiation damage during the life of the zircons. The 207-Pb/206-Pb ratios for these nm-scale domains, as measured by LEAP, average 0.17 for the 2.4 Ga Zrc2 (3 needles) and 0.43 for the 4.0 Ga Zrc1 (5 needles). These ratios are less precise (±40% 2σ) due to ultra-small sample size, but are in excellent agreement with values measured by SIMS, 0.1684 and 0.4269, respectively. Thus Pb in both zircons is radiogenic. The Pb-Y-rich domains and lack of

  13. Single mode solid state distributed feedback dye laser fabricated by grey scale electron beam lithography on dye doped SU-8 resist

    DEFF Research Database (Denmark)

    Balslev, Søren; Rasmussen, Torben; Shi, Peixiong

    2005-01-01

    We demonstrate grey scale electron beam lithography on functionalized SU-8 resist for fabrication of single mode solid state dye laser devices. The resist is doped with Rhodamine 6G perchlorate and the lasers are based on a first order Bragg grating distributed feedback resonator. The lasers...

  14. Concurrent Validity and Sensitivity to Change of Direct Behavior Rating Single-Item Scales (DBR-SIS) within an Elementary Sample

    Science.gov (United States)

    Smith, Rhonda L.; Eklund, Katie; Kilgus, Stephen P.

    2018-01-01

    The purpose of this study was to evaluate the concurrent validity, sensitivity to change, and teacher acceptability of Direct Behavior Rating single-item scales (DBR-SIS), a brief progress monitoring measure designed to assess student behavioral change in response to intervention. Twenty-four elementary teacher-student dyads implemented a daily…

  15. Regional control of melanoma neck node metastasis after selective neck dissection with or without adjuvant radiotherapy

    NARCIS (Netherlands)

    Hamming-Vrieze, Olga; Balm, Alfons J. M.; Heemsbergen, Wilma D.; Hooft van Huysduynen, Thijs; Rasch, Coen R. N.

    2009-01-01

    OBJECTIVE: To examine the effect of adjuvant radiotherapy on regional control of melanoma neck node metastasis. DESIGN: A single-institution retrospective study. SETTING: Tertiary care cancer center. PATIENTS: The study included 64 patients with melanoma neck node metastasis who were treated with

  16. Distributed Component Forests : Hierarchical Image Representations Suitable for Tera-Scale Images

    NARCIS (Netherlands)

    Wilkinson, M.H.F.; Gazagnes, Simon; Suen, Ching Y.

    2018-01-01

    The standard representations know as component trees, used in morphological connected attribute filtering and multi-scale analysis, are unsuitable for cases in which either the image itself, or the tree do not fit in the memory of a single compute node. Recently, a new structure has been developed

  17. Predictions of the spontaneous symmetry-breaking theory for visual code completeness and spatial scaling in single-cell learning rules.

    Science.gov (United States)

    Webber, C J

    2001-05-01

    This article shows analytically that single-cell learning rules that give rise to oriented and localized receptive fields, when their synaptic weights are randomly and independently initialized according to a plausible assumption of zero prior information, will generate visual codes that are invariant under two-dimensional translations, rotations, and scale magnifications, provided that the statistics of their training images are sufficiently invariant under these transformations. Such codes span different image locations, orientations, and size scales with equal economy. Thus, single-cell rules could account for the spatial scaling property of the cortical simple-cell code. This prediction is tested computationally by training with natural scenes; it is demonstrated that a single-cell learning rule can give rise to simple-cell receptive fields spanning the full range of orientations, image locations, and spatial frequencies (except at the extreme high and low frequencies at which the scale invariance of the statistics of digitally sampled images must ultimately break down, because of the image boundary and the finite pixel resolution). Thus, no constraint on completeness, or any other coupling between cells, is necessary to induce the visual code to span wide ranges of locations, orientations, and size scales. This prediction is made using the theory of spontaneous symmetry breaking, which we have previously shown can also explain the data-driven self-organization of a wide variety of transformation invariances in neurons' responses, such as the translation invariance of complex cell response.

  18. Controlling data transfers from an origin compute node to a target compute node

    Science.gov (United States)

    Archer, Charles J [Rochester, MN; Blocksome, Michael A [Rochester, MN; Ratterman, Joseph D [Rochester, MN; Smith, Brian E [Rochester, MN

    2011-06-21

    Methods, apparatus, and products are disclosed for controlling data transfers from an origin compute node to a target compute node that include: receiving, by an application messaging module on the target compute node, an indication of a data transfer from an origin compute node to the target compute node; and administering, by the application messaging module on the target compute node, the data transfer using one or more messaging primitives of a system messaging module in dependence upon the indication.

  19. Allocating resources between network nodes for providing a network node function

    OpenAIRE

    Strijkers, R.J.; Meulenhoff, P.J.

    2014-01-01

    The invention provides a method wherein a first network node advertises available resources that a second network node may use to offload network node functions transparently to the first network node. Examples of the first network node are a client device (e.g. PC, notebook, tablet, smart phone), a server (e.g. application server, a proxy server, cloud location, router). Examples of the second network node are an application server, a cloud location or a router. The available resources may b...

  20. Secure message authentication system for node to node network

    Science.gov (United States)

    Sindhu, R.; Vanitha, M. M.; Norman, J.

    2017-10-01

    The Message verification remains some of the best actual methods for prevent the illegal and dis honored communication after presence progressed to WSNs (Wireless Sensor Networks). Intend for this purpose, several message verification systems must stand established, created on both symmetric key cryptography otherwise public key cryptosystems. Best of them will have some limits for great computational then statement above in count of deficiency of climb ability then flexibility in node settlement occurrence. In a polynomial based system was newly presented for these problems. Though, this system then situations delay will must the dimness of integral limitation firm in the point of polynomial: once the amount of message transferred remains the greater than the limitation then the opponent will completely improve the polynomial approaches. This paper suggests using ECC (Elliptic Curve Cryptography). Though using the node verification the technique in this paper permits some nodes to transfer a limitless amount of messages lacking misery in the limit problem. This system will have the message cause secrecy. Equally theoretic study then model effects show our planned system will be effective than the polynomial based method in positions of calculation then statement above in privacy points though message basis privacy.

  1. Critical node lifetimes in random networks via the Chen-Stein method

    NARCIS (Netherlands)

    Franceschetti, M.; Meester, R.W.J.

    2006-01-01

    This correspondence considers networks where nodes are connected randomly and can fail at random times. It provides scaling laws that allow to find the critical time at which isolated nodes begin to appear in the system as its size tends to infinity. Applications are in the areas of sensor and

  2. LA PLANTA ÚNICA COMO TIPO RESISTENTE A LA ESCALA / the single plan as a type resistant to scale

    Directory of Open Access Journals (Sweden)

    Silvia Colmenares Vilata

    2014-05-01

    centre and the container with the periphery is still valid, because the necessary density of the first and the extensive occupation of the second mean that it is impossible to invert the terms. However, both represent the strictly pragmatic development of the principles of the “free plan” as a generic operating system, giving rise to large constructions that test the resistance to the scale of the type itself. Taking the characteristic neutrality of the “single plan” as a reference, the text analyses the behaviour with regard to the change of size of its two complementary configurations: the large hypostile hall and the clear-span pavillion.

  3. Optimizing the performance of small-scale organic Rankine cycle that utilizes a single-screw expander

    International Nuclear Information System (INIS)

    Ziviani, D.; Gusev, S.; Lecompte, S.; Groll, E.A.; Braun, J.E.; Horton, W.T.; Broek, M. van den; De Paepe, M.

    2017-01-01

    Highlights: • A total of 102 steady-state points with R245fa and SES336 have been collected. • R245fa led to 10% higher power output despite lower expander isentropic efficiency. • The ORC running with SES36 presented a better matching between expander and cycle. • The theoretical matching between expander volume ratio and cycle efficiency is determined. • Steady-state performance maps are used to build a feed-forward controller. - Abstract: This paper deals with the operation and optimization of a down-scaled industrial organic Rankine cycle (ORC) for low-grade waste heat recovery. The system is a sub-critical regenerative ORC with a nominal power output of 11 kW. The ORC unit has been assembled using off-the-shelf components including three identical plate heat exchangers, a liquid receiver, a multi-stage centrifugal pump and a single-screw compressor adapted to operate as an expander. The experimental results are used to evaluate the influence of the expander performance on the behavior of the ORC system at nominal and part-load conditions. The matching between the volumetric expander and the system operating conditions is also analyzed. Results showed that in the case of SES36, both the expander efficiency and system performance were maximized for a pressure ratio between 7 and 9. In the case of R245fa, while the system efficiency achieved values similar to SES36, but the expander maximum isentropic efficiency was 17% lower. Two analyses are carried out to optimize the operation of the ORC unit with R245fa. At first, the insights gained by analyzing the experimental data are used to evaluate the theoretical matching between volumetric expander and the system maximum efficiency in terms of the Second Law of thermodynamics. Secondly, a control-oriented steady-state cycle model based on empirical correlations calibrated on the experimental results is developed. The model is used to implement a feed-forward control strategy based on predetermined steady

  4. Data Fusion Based on Node Trust Evaluation in Wireless Sensor Networks

    Directory of Open Access Journals (Sweden)

    Zhou Jianming

    2014-01-01

    Full Text Available Abnormal behavior detection and trust evaluation mode of traditional sensor node have a single function without considering all the factors, and the trust value algorithm is relatively complicated. To avoid these above disadvantages, a trust evaluation model based on the autonomous behavior of sensor node is proposed in this paper. Each sensor node has the monitoring privilege and obligation. Neighboring sensor nodes can monitor each other. Their direct and indirect trust values can be achieved by using a relatively simple calculation method, the synthesis trust value of which could be got according to the composition rule of D-S evidence theory. Firstly, the cluster head assigns different weighted value for the data from each sensor node, then the weight vector is set according to the synthesis trust value, the data fusion processing is executed, and finally the cluster head sensor node transmits the fused result to the base station. Simulation experiment results demonstrate that the trust evaluation model can rapidly, exactly, and effectively recognize malicious sensor node and avoid malicious sensor node becoming cluster head sensor node. The proposed algorithm can greatly increase the safety and accuracy of data fusion, improve communication efficiency, save energy of sensor node, suit different application fields, and deploy environments.

  5. Codimension n saddle-nodes

    International Nuclear Information System (INIS)

    Gheiner, Jaques

    2014-01-01

    We consider the generic unfolding of a diffeomorphism on a compact C ∞ manifold that is Morse–Smale except for one non-hyperbolic periodic orbit being a codimension n saddle-node (one eigenvalue is 1, the other eigenvalues have norm different from 1). Local and global bifurcations are described. We characterize structural stability of the unfolding, depending on the codimension. A universal model of the unfolding is given when there is stability. Dynamical behaviour is analysed in other cases. (paper)

  6. Axillary Lymph Nodes and Breast Cancer

    Science.gov (United States)

    ... white blood cells that help fight illness. If breast cancer spreads, the lymph nodes in the underarm (called ... if they contain cancer cells. This helps determine breast cancer stage and guide treatment. Sentinel node biopsy and ...

  7. Sentinel Node in Oral Cancer

    DEFF Research Database (Denmark)

    Tartaglione, Girolamo; Stoeckli, Sandro J; de Bree, Remco

    2016-01-01

    /static scan and/or SPECT/CT. RESULTS: Lymphoscintigraphy identified 723 lymphatic basins. 1398 sentinel lymph nodes (SNs) were biopsied (3.2 SN per patient; range, 1-10). Dynamic scan allowed the differentiation of sentinel nodes from second tier lymph nodes. SPECT/CT allowed more accurate anatomical......PURPOSE: Nuclear imaging plays a crucial role in lymphatic mapping of oral cancer. This evaluation represents a subanalysis of the original multicenter SENT trial data set, involving 434 patients with T1-T2, N0, and M0 oral squamous cell carcinoma. The impact of acquisition techniques, tracer...... localization and estimated SN depth more efficiently. After pathological examination, 9.9% of the SN excised (138 of 1398 SNs) showed metastases. The first neck level (NL) containing SN+ was NL I in 28.6%, NL IIa in 44.8%, NL IIb in 2.8%, NL III in 17.1%, and NL IV in 6.7% of positive patients. Approximately...

  8. The hidden sentinel node in breast cancer

    NARCIS (Netherlands)

    Tanis, P. J.; van Sandick, J. W.; Nieweg, O. E.; Valdés Olmos, R. A.; Rutgers, E. J. T.; Hoefnagel, C. A.; Kroon, B. B. R.

    2002-01-01

    The purpose of this study was to analyse the occurrence of non-visualisation during preoperative lymphoscintigraphy for sentinel node identification in breast cancer. Preoperative lymphoscintigraphy was performed in 495 clinically node-negative breast cancer patients (501 sentinel node procedures)

  9. T.Node, industrial version of supernode

    Science.gov (United States)

    Flieller, Sylvain

    1989-12-01

    The Esprit I P1085 "SuperNode" project developed a modular reconfigurable archtecture, based on transputers. This highly parallel machine is now marketed by Telmat Informatique under the name T.Node. This paper presents the P1085 project, the architecture of SuperNode, its industrial implementation and its software enviroment.

  10. CT perfusion study of neck lymph nodes

    International Nuclear Information System (INIS)

    Zhong Jin; Liu Jun; Hua Rui; Qiao Hui; Gong Yi

    2011-01-01

    Objective: To study the CT perfusion features of various lymph nodes in the neck. Methods: Dynamic perfusion CT scanning was performed in 83 neck lymph nodes proved by pathology, including tuberculosis lymph nodes, lymphoma and metastatic lymph nodes. The shapes, blood flow modes, and perfusion parameters of these lymph nodes were compared among 3 groups. Statistical analysis of L/T and CT perfusion parameters was performed by one-way ANOVA and LSD test. Results: The values of MTT of tuberculosis lymph nodes, lymphoma and metastatic lymph nodes were (28.13±5.08), (31.08±5.82), and (11.24±5.31) s, respectively. The MTT of metastatic lymph nodes was statistically lower than that of tuberculosis lymph nodes and lymphoma (P -1 · 100 g -1 , respectively. The values of BV were (24.68±2.84), (25.30±3.16), and (25.15± 8.81) ml·100 g -1 respectively. The values of TTP were (40.90±8.85), (40.67±6.45), and (40.98±6.62) s, respectively. There were no significant differences in L/T, BF, BV and TTP among tuberculosis lymph nodes, lymphoma and metastatic lymph nodes (P>0.05). Conclusion: CT perfusion, especially combination functional imaging with perfusion images may be helpful in judging the nature of neck lymph nodes. (authors)

  11. blastjs: a BLAST+ wrapper for Node.js.

    Science.gov (United States)

    Page, Martin; MacLean, Dan; Schudoma, Christian

    2016-02-27

    To cope with the ever-increasing amount of sequence data generated in the field of genomics, the demand for efficient and fast database searches that drive functional and structural annotation in both large- and small-scale genome projects is on the rise. The tools of the BLAST+ suite are the most widely employed bioinformatic method for these database searches. Recent trends in bioinformatics application development show an increasing number of JavaScript apps that are based on modern frameworks such as Node.js. Until now, there is no way of using database searches with the BLAST+ suite from a Node.js codebase. We developed blastjs, a Node.js library that wraps the search tools of the BLAST+ suite and thus allows to easily add significant functionality to any Node.js-based application. blastjs is a library that allows the incorporation of BLAST+ functionality into bioinformatics applications based on JavaScript and Node.js. The library was designed to be as user-friendly as possible and therefore requires only a minimal amount of code in the client application. The library is freely available under the MIT license at https://github.com/teammaclean/blastjs.

  12. Deployment of check-in nodes in complex networks

    Science.gov (United States)

    Jiang, Zhong-Yuan; Ma, Jian-Feng

    2017-01-01

    In many real complex networks such as the city road networks and highway networks, vehicles often have to pass through some specially functioned nodes to receive check-in like services such as gas supplement at gas stations. Based on existing network structures, to guarantee every shortest path including at least a check-in node, the location selection of all check-in nodes is very essential and important to make vehicles to easily visit these check-in nodes, and it is still remains an open problem in complex network studies. In this work, we aim to find possible solutions for this problem. We first convert it into a set cover problem which is NP-complete and propose to employ the greedy algorithm to achieve an approximate result. Inspired by heuristic information of network structure, we discuss other four check-in node location deployment methods including high betweenness first (HBF), high degree first (HDF), random and low degree first (LDF). Finally, we compose extensive simulations in classical scale-free networks, random networks and real network models, and the results can well confirm the effectiveness of the greedy algorithm. This work has potential applications into many real networks.

  13. Sentinel node concept in breast cancer

    International Nuclear Information System (INIS)

    Kiricuta, I.C.

    2000-01-01

    Background/purpose: It seems that there exists a specific lymph node center called sentinel node (SN) which appears to be the primary site of metastases. The sentinel node concept (SNC) is fundamentally based on the orderly progression of tumor cells within the lymphatic system. It is the most important new concept in surgical and radiation oncology. The purpose is to present the biological significance, the diagnostic and clinical basis of the sentinel node concept in breast cancer patients. Material and methods: Lymphoscintigraphy and gamma probe biopsy is necessary to show predictable lymph flow to the regional sentinel node, to multiple sentinel nodes or unpredictable lymph flow to extra-regional sentinel nodes and for performing sentinel node procedure. The standard protocol for the evaluation of the sentinel node metastases consists of extensive histopathological investigation including step Hematoxylin and Eosin (H and E) stained sections and immunohistochemistry. Results: A high rate of success of the identification of the sentinel node for breast cancer was reported. The presence or absence of metastasis in this node is a very accurate predictor of overall nodal status. The temptation to examine the sentinel node with the greatest possible degree of accuracy highlights one of the major problems related to sentinel node biopsy. The success of the sentinel node procedure depends primarily on the adequate functional capacity necessary for sufficient uptake to ensure the accurate identification. In negative sentinel-node patients a complete axillary lymph node dissection is avoidable. In sentinel-node positive patients and clinically negative patients a postoperative radiotherapy would permit an adequate tumor control. The last 2-procedures permit a low morbidity. In the actual TNM classification it was recently introduced a definition of a 'pN0' patient based on sentinel node biopsy. New target volumes are defined for adjuvant radiotherapy or lymphatic basins

  14. The supply voltage scaled dependency of the recovery of single event upset in advanced complementary metal—oxide—semiconductor static random-access memory cells

    International Nuclear Information System (INIS)

    Li Da-Wei; Qin Jun-Rui; Chen Shu-Ming

    2013-01-01

    Using computer-aided design three-dimensional simulation technology, the supply voltage scaled dependency of the recovery of single event upset and charge collection in static random-access memory cells are investigated. It reveals that the recovery linear energy transfer threshold decreases with the supply voltage reducing, which is quite attractive for dynamic voltage scaling and subthreshold circuit radiation-hardened design. Additionally, the effect of supply voltage on charge collection is also investigated. It is concluded that the supply voltage mainly affects the bipolar gain of the parasitical bipolar junction transistor (BJT) and the existence of the source plays an important role in supply voltage variation. (geophysics, astronomy, and astrophysics)

  15. Evaluating cloud processes in large-scale models: Of idealized case studies, parameterization testbeds and single-column modelling on climate time-scales

    Science.gov (United States)

    Neggers, Roel

    2016-04-01

    Boundary-layer schemes have always formed an integral part of General Circulation Models (GCMs) used for numerical weather and climate prediction. The spatial and temporal scales associated with boundary-layer processes and clouds are typically much smaller than those at which GCMs are discretized, which makes their representation through parameterization a necessity. The need for generally applicable boundary-layer parameterizations has motivated many scientific studies, which in effect has created its own active research field in the atmospheric sciences. Of particular interest has been the evaluation of boundary-layer schemes at "process-level". This means that parameterized physics are studied in isolated mode from the larger-scale circulation, using prescribed forcings and excluding any upscale interaction. Although feedbacks are thus prevented, the benefit is an enhanced model transparency, which might aid an investigator in identifying model errors and understanding model behavior. The popularity and success of the process-level approach is demonstrated by the many past and ongoing model inter-comparison studies that have been organized by initiatives such as GCSS/GASS. A red line in the results of these studies is that although most schemes somehow manage to capture first-order aspects of boundary layer cloud fields, there certainly remains room for improvement in many areas. Only too often are boundary layer parameterizations still found to be at the heart of problems in large-scale models, negatively affecting forecast skills of NWP models or causing uncertainty in numerical predictions of future climate. How to break this parameterization "deadlock" remains an open problem. This presentation attempts to give an overview of the various existing methods for the process-level evaluation of boundary-layer physics in large-scale models. This includes i) idealized case studies, ii) longer-term evaluation at permanent meteorological sites (the testbed approach

  16. Mediastinal lymph node detection and station mapping on chest CT using spatial priors and random forest

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Jiamin; Hoffman, Joanne; Zhao, Jocelyn; Yao, Jianhua; Lu, Le; Kim, Lauren; Turkbey, Evrim B.; Summers, Ronald M., E-mail: rms@nih.gov [Imaging Biomarkers and Computer-aided Diagnosis Laboratory, Radiology and Imaging Sciences, National Institutes of Health Clinical Center Building, 10 Room 1C224 MSC 1182, Bethesda, Maryland 20892-1182 (United States)

    2016-07-15

    Purpose: To develop an automated system for mediastinal lymph node detection and station mapping for chest CT. Methods: The contextual organs, trachea, lungs, and spine are first automatically identified to locate the region of interest (ROI) (mediastinum). The authors employ shape features derived from Hessian analysis, local object scale, and circular transformation that are computed per voxel in the ROI. Eight more anatomical structures are simultaneously segmented by multiatlas label fusion. Spatial priors are defined as the relative multidimensional distance vectors corresponding to each structure. Intensity, shape, and spatial prior features are integrated and parsed by a random forest classifier for lymph node detection. The detected candidates are then segmented by the following curve evolution process. Texture features are computed on the segmented lymph nodes and a support vector machine committee is used for final classification. For lymph node station labeling, based on the segmentation results of the above anatomical structures, the textual definitions of mediastinal lymph node map according to the International Association for the Study of Lung Cancer are converted into patient-specific color-coded CT image, where the lymph node station can be automatically assigned for each detected node. Results: The chest CT volumes from 70 patients with 316 enlarged mediastinal lymph nodes are used for validation. For lymph node detection, their system achieves 88% sensitivity at eight false positives per patient. For lymph node station labeling, 84.5% of lymph nodes are correctly assigned to their stations. Conclusions: Multiple-channel shape, intensity, and spatial prior features aggregated by a random forest classifier improve mediastinal lymph node detection on chest CT. Using the location information of segmented anatomic structures from the multiatlas formulation enables accurate identification of lymph node stations.

  17. Mediastinal lymph node detection and station mapping on chest CT using spatial priors and random forest

    International Nuclear Information System (INIS)

    Liu, Jiamin; Hoffman, Joanne; Zhao, Jocelyn; Yao, Jianhua; Lu, Le; Kim, Lauren; Turkbey, Evrim B.; Summers, Ronald M.

    2016-01-01

    Purpose: To develop an automated system for mediastinal lymph node detection and station mapping for chest CT. Methods: The contextual organs, trachea, lungs, and spine are first automatically identified to locate the region of interest (ROI) (mediastinum). The authors employ shape features derived from Hessian analysis, local object scale, and circular transformation that are computed per voxel in the ROI. Eight more anatomical structures are simultaneously segmented by multiatlas label fusion. Spatial priors are defined as the relative multidimensional distance vectors corresponding to each structure. Intensity, shape, and spatial prior features are integrated and parsed by a random forest classifier for lymph node detection. The detected candidates are then segmented by the following curve evolution process. Texture features are computed on the segmented lymph nodes and a support vector machine committee is used for final classification. For lymph node station labeling, based on the segmentation results of the above anatomical structures, the textual definitions of mediastinal lymph node map according to the International Association for the Study of Lung Cancer are converted into patient-specific color-coded CT image, where the lymph node station can be automatically assigned for each detected node. Results: The chest CT volumes from 70 patients with 316 enlarged mediastinal lymph nodes are used for validation. For lymph node detection, their system achieves 88% sensitivity at eight false positives per patient. For lymph node station labeling, 84.5% of lymph nodes are correctly assigned to their stations. Conclusions: Multiple-channel shape, intensity, and spatial prior features aggregated by a random forest classifier improve mediastinal lymph node detection on chest CT. Using the location information of segmented anatomic structures from the multiatlas formulation enables accurate identification of lymph node stations.

  18. Lymph node detection in IASLC-defined zones on PET/CT images

    Science.gov (United States)

    Song, Yihua; Udupa, Jayaram K.; Odhner, Dewey; Tong, Yubing; Torigian, Drew A.

    2016-03-01

    Lymph node detection is challenging due to the low contrast between lymph nodes as well as surrounding soft tissues and the variation in nodal size and shape. In this paper, we propose several novel ideas which are combined into a system to operate on positron emission tomography/ computed tomography (PET/CT) images to detect abnormal thoracic nodes. First, our previous Automatic Anatomy Recognition (AAR) approach is modified where lymph node zones predominantly following International Association for the Study of Lung Cancer (IASLC) specifications are modeled as objects arranged in a hierarchy along with key anatomic anchor objects. This fuzzy anatomy model built from diagnostic CT images is then deployed on PET/CT images for automatically recognizing the zones. A novel globular filter (g-filter) to detect blob-like objects over a specified range of sizes is designed to detect the most likely locations and sizes of diseased nodes. Abnormal nodes within each automatically localized zone are subsequently detected via combined use of different items of information at various scales: lymph node zone model poses found at recognition indicating the geographic layout at the global level of node clusters, g-filter response which hones in on and carefully selects node-like globular objects at the node level, and CT and PET gray value but within only the most plausible nodal regions for node presence at the voxel level. The models are built from 25 diagnostic CT scans and refined for an object hierarchy based on a separate set of 20 diagnostic CT scans. Node detection is tested on an additional set of 20 PET/CT scans. Our preliminary results indicate node detection sensitivity and specificity at around 90% and 85%, respectively.

  19. Offloading of a Wireless Node Authentication with Core Network

    DEFF Research Database (Denmark)

    2017-01-01

    An example technique may include controlling receiving, by a second node from a first node in a wireless network, a request to offload authentication of the first node with the core network to the second node, controlling receiving, by the second node from the first node, data to be forwarded...... to the core network, performing, by the second node based on the request, an authentication with the core network on behalf of the first node while the first node is not connected with the second node, and controlling forwarding the received data from the second node to the core network while the first node...

  20. Recognition of earthquake-prone nodes, a case study for North Vietnam (M ⩾ 5.0

    Directory of Open Access Journals (Sweden)

    Nguyen Huu Tuyen

    2012-05-01

    Full Text Available Morphostructural nodes in North Vietnam are delineated with the morphostructural zoning (MZ method, and classified into seismogenic and non-seismogenic nodes. The compiled morphostructural map (scale 1: 1000000 shows a three-level hierarchical structure of blocks, boundary zones, and nodes. The identified nodes are classified with the pattern-recognition algorithm CORA-3 into those that are prone to generate M ⩾ 5.0 earthquakes and those that are not. Some of the earthquake-prone nodes coincide with epicenters of M ⩾ 5.0 earthquakes that have occurred; others may coincide with such events in the future.

  1. Automatic single questionnaire intensity (SQI, EMS98 scale) estimation using ranking models built on the existing BCSF database

    Science.gov (United States)

    Schlupp, A.; Sira, C.; Schmitt, K.; Schaming, M.

    2013-12-01

    In charge of intensity estimations in France, BCSF has collected and manually analyzed more than 47000 online individual macroseismic questionnaires since 2000 up to intensity VI. These macroseismic data allow us to estimate one SQI value (Single Questionnaire Intensity) for each form following the EMS98 scale. The reliability of the automatic intensity estimation is important as they are today used for automatic shakemaps communications and crisis management. Today, the automatic intensity estimation at BCSF is based on the direct use of thumbnails selected on a menu by the witnesses. Each thumbnail corresponds to an EMS-98 intensity value, allowing us to quickly issue an intensity map of the communal intensity by averaging the SQIs at each city. Afterwards an expert, to determine a definitive SQI, manually analyzes each form. This work is time consuming and not anymore suitable considering the increasing number of testimonies at BCSF. Nevertheless, it can take into account incoherent answers. We tested several automatic methods (USGS algorithm, Correlation coefficient, Thumbnails) (Sira et al. 2013, IASPEI) and compared them with 'expert' SQIs. These methods gave us medium score (between 50 to 60% of well SQI determined and 35 to 40% with plus one or minus one intensity degree). The best fit was observed with the thumbnails. Here, we present new approaches based on 3 statistical ranking methods as 1) Multinomial logistic regression model, 2) Discriminant analysis DISQUAL and 3) Support vector machines (SVMs). The two first methods are standard methods, while the third one is more recent. Theses methods could be applied because the BCSF has already in his database more then 47000 forms and because their questions and answers are well adapted for a statistical analysis. The ranking models could then be used as automatic method constrained on expert analysis. The performance of the automatic methods and the reliability of the estimated SQI can be evaluated thanks to

  2. Identifying Nodes of Transmission in Disease Diffusion Through Social Media

    Science.gov (United States)

    Lamb, David Sebastian

    The spread of infectious diseases can be described in terms of three interrelated components: interaction, movement, and scale. Transmission between individuals requires some form of interaction, which is dependent on the pathogen, to occur. Diseases spread through the movement of their hosts; they spread across many spatial scales from local neighborhoods to countries, or temporal scales from days to years, or periodic intervals. Prior research into the spread of disease have examined diffusion processes retrospectively at regional or country levels, or developed differential equation or simulation models of the dynamics of disease transmission. While some of the more recent models incorporate all three components, they are limited in the way they understand where interactions occur. The focus has been on home or work, including contact with family or coworkers. The models reflect a lack of knowledge about how transmissions are made at specific locations in time, so-called nodes of transmission. That is, how individuals' intersections in time and space function in disease transmission. This project sought to use the three factors of interaction, movement, and scale to better understand the spread of disease in terms of the place of interaction called the node of transmission. The overarching objective of this research was: how can nodes of transmission be identified through individual activity spaces incorporating the three factors of infectious disease spread: interaction, movement, and scale?. This objective fed into three main sub-objectives: defining nodes of transmission, developing an appropriate methodology to identifying nodes of transmission, and applying it using geotagged social media data from Twitter. To develop an appropriate framework, this research relied on time geography, and traditional disease. This particularly relied on the idea of bundling to create the nodes, and a nesting effect that integrated scale. The data source used to identify nodes

  3. Sentinel lymph node biopsy in oral cancer

    DEFF Research Database (Denmark)

    Thomsen, Jørn Bo; Sørensen, Jens Ahm; Grupe, Peter

    2005-01-01

    PURPOSE: To validate lymphatic mapping combined with sentinel lymph node biopsy as a staging procedure, and to evaluate the possible clinical implications of added oblique lymphoscintigraphy and/or tomography and test the intra- and interobserver reproducibility of lymphoscintigraphy. MATERIAL......: Eleven (28%) patients were upstaged. The sentinel lymph node identification rate was 97.5%. Sentinel lymph node biopsy significantly differentiated between patients with or without lymph node metastasis (P = 0.001). Lymphatic mapping revealed 124 hotspots and 144 hot lymph nodes were removed by sentinel...

  4. Converting Simulated Sodium-bearing Waste into a Single Solid Waste Form by Evaporation: Laboratory- and Pilot-Scale Test Results on Recycling Evaporator Overheads

    Energy Technology Data Exchange (ETDEWEB)

    Griffith, D.; D. L. Griffith; R. J. Kirkham; L. G. Olson; S. J. Losinski

    2004-01-01

    Conversion of Idaho National Engineering and Environmental Laboratory radioactive sodium-bearing waste into a single solid waste form by evaporation was demonstrated in both flask-scale and pilot-scale agitated thin film evaporator tests. A sodium-bearing waste simulant was adjusted to represent an evaporator feed in which the acid from the distillate is concentrated, neutralized, and recycled back through the evaporator. The advantage to this flowsheet is that a single remote-handled transuranic waste form is produced in the evaporator bottoms without the generation of any low-level mixed secondary waste. However, use of a recycle flowsheet in sodium-bearing waste evaporation results in a 50% increase in remote-handled transuranic volume in comparison to a non-recycle flowsheet.

  5. Pattern of Colon Cancer Lymph Node Metastases in Patients Undergoing Central Mesocolic Lymph Node Excision

    DEFF Research Database (Denmark)

    Bertelsen, Claus A; Kirkegaard-Klitbo, Anders; Nielsen, Mingyuan

    2016-01-01

    BACKGROUND: Extended mesocolic lymph node dissection in colon cancer surgery seems to improve oncological outcome. A possible reason might be related to metastases in the central mesocolic lymph nodes. OBJECTIVE: The purpose of this study was to describe the pattern of mesocolic lymph node...... metastases, particularly in central lymph nodes, and the risk of skip, aberrant, and gastrocolic ligament metastases as the argument for performing extended lymph node dissection. DATA SOURCES: EMBASE and PubMed were searched using the terms colon or colorectal with sentinel node, lymph node mapping, or skip...... node; lymph node resection colon; and complete or total and mesocolic excision. STUDY SELECTION: Studies describing the risk of metastases in central, skip, aberrant, and gastrocolic ligament lymph node metastases from colon adenocarcinomas in 10 or more patients were included. No languages were...

  6. Optical biopsy of lymph node morphology using optical coherence tomography.

    Science.gov (United States)

    Luo, Wei; Nguyen, Freddy T; Zysk, Adam M; Ralston, Tyler S; Brockenbrough, John; Marks, Daniel L; Oldenburg, Amy L; Boppart, Stephen A

    2005-10-01

    Optical diagnostic imaging techniques are increasingly being used in the clinical environment, allowing for improved screening and diagnosis while minimizing the number of invasive procedures. Diffuse optical tomography, for example, is capable of whole-breast imaging and is being developed as an alternative to traditional X-ray mammography. While this may eventually be a very effective screening method, other optical techniques are better suited for imaging on the cellular and molecular scale. Optical Coherence Tomography (OCT), for instance, is capable of high-resolution cross-sectional imaging of tissue morphology. In a manner analogous to ultrasound imaging except using optics, pulses of near-infrared light are sent into the tissue while coherence-gated reflections are measured interferometrically to form a cross-sectional image of tissue. In this paper we apply OCT techniques for the high-resolution three-dimensional visualization of lymph node morphology. We present the first reported OCT images showing detailed morphological structure and corresponding histological features of lymph nodes from a carcinogen-induced rat mammary tumor model, as well as from a human lymph node containing late stage metastatic disease. The results illustrate the potential for OCT to visualize detailed lymph node structures on the scale of micrometastases and the potential for the detection of metastatic nodal disease intraoperatively.

  7. Targeted Delivery of Immunomodulators to Lymph Nodes

    Directory of Open Access Journals (Sweden)

    Jamil Azzi

    2016-05-01

    Full Text Available Active-targeted delivery to lymph nodes represents a major advance toward more effective treatment of immune-mediated disease. The MECA79 antibody recognizes peripheral node addressin molecules expressed by high endothelial venules of lymph nodes. By mimicking lymphocyte trafficking to the lymph nodes, we have engineered MECA79-coated microparticles containing an immunosuppressive medication, tacrolimus. Following intravenous administration, MECA79-bearing particles showed marked accumulation in the draining lymph nodes of transplanted animals. Using an allograft heart transplant model, we show that targeted lymph node delivery of microparticles containing tacrolimus can prolong heart allograft survival with negligible changes in tacrolimus serum level. Using MECA79 conjugation, we have demonstrated targeted delivery of tacrolimus to the lymph nodes following systemic administration, with the capacity for immune modulation in vivo.

  8. Sentinel node biopsy before neoadjuvant chemotherapy spares breast cancer patients axillary lymph node dissection.

    Science.gov (United States)

    van Rijk, Maartje C; Nieweg, Omgo E; Rutgers, Emiel J T; Oldenburg, Hester S A; Olmos, Renato Valdés; Hoefnagel, Cornelis A; Kroon, Bin B R

    2006-04-01

    Neoadjuvant chemotherapy in breast cancer patients is a valuable method to determine the efficacy of chemotherapy and potentially downsize the primary tumor, which facilitates breast-conserving therapy. In 18 studies published about sentinel node biopsy after neoadjuvant chemotherapy, the sentinel node was identified in on average 89%, and the false-negative rate was on average 10%. Because of these mediocre results, no author dares to omit axillary clearance just yet. In our institute, sentinel lymph node biopsy is performed before neoadjuvant chemotherapy. The aim of this study was to evaluate our experience with this approach. Sentinel node biopsy was performed before neoadjuvant chemotherapy in 25 T2N0 patients by using lymphoscintigraphy, a gamma ray detection probe, and patent blue dye. Axillary lymph node dissection was performed after chemotherapy if the sentinel node contained metastases. Ten patients had a tumor-positive axillary sentinel node, and one patient had an involved lateral intramammary node. Four patients had additional involved nodes in the completion lymph node dissection specimen. The other 14 patients (56%) had a tumor-negative sentinel node and did not undergo axillary lymph node dissection. No recurrences have been observed after a median follow-up of 18 months. Fourteen (56%) of the 25 patients were spared axillary lymph node dissection when the sentinel node was found to be disease free. Performing sentinel node biopsy before neoadjuvant chemotherapy seems successful and reliable in patients with T2N0 breast cancer.

  9. Empirical modeling of single-wake advection and expansion using full-scale pulsed lidar-based measurements

    DEFF Research Database (Denmark)

    Machefaux, Ewan; Larsen, Gunner Chr.; Troldborg, Niels

    2015-01-01

    In the present paper, single-wake dynamics have been studied both experimentally and numerically. The use of pulsed lidar measurements allows for validation of basic dynamic wake meandering modeling assumptions. Wake center tracking is used to estimate the wake advection velocity experimentally...... fairly well in the far wake but lacks accuracy in the outer region of the near wake. An empirical relationship, relating maximum wake induction and wake advection velocity, is derived and linked to the characteristics of a spherical vortex structure. Furthermore, a new empirical model for single...

  10. From single steps to mass migration: the problem of scale in the movement ecology of the Serengeti wildebeest.

    Science.gov (United States)

    Torney, Colin J; Hopcraft, J Grant C; Morrison, Thomas A; Couzin, Iain D; Levin, Simon A

    2018-05-19

    A central question in ecology is how to link processes that occur over different scales. The daily interactions of individual organisms ultimately determine community dynamics, population fluctuations and the functioning of entire ecosystems. Observations of these multiscale ecological processes are constrained by various technological, biological or logistical issues, and there are often vast discrepancies between the scale at which observation is possible and the scale of the question of interest. Animal movement is characterized by processes that act over multiple spatial and temporal scales. Second-by-second decisions accumulate to produce annual movement patterns. Individuals influence, and are influenced by, collective movement decisions, which then govern the spatial distribution of populations and the connectivity of meta-populations. While the field of movement ecology is experiencing unprecedented growth in the availability of movement data, there remain challenges in integrating observations with questions of ecological interest. In this article, we present the major challenges of addressing these issues within the context of the Serengeti wildebeest migration, a keystone ecological phenomena that crosses multiple scales of space, time and biological complexity.This article is part of the theme issue 'Collective movement ecology'. © 2018 The Author(s).

  11. Statistical shape model-based reconstruction of a scaled, patient-specific surface model of the pelvis from a single standard AP x-ray radiograph

    Energy Technology Data Exchange (ETDEWEB)

    Zheng Guoyan [Institute for Surgical Technology and Biomechanics, University of Bern, Stauffacherstrasse 78, CH-3014 Bern (Switzerland)

    2010-04-15

    Purpose: The aim of this article is to investigate the feasibility of using a statistical shape model (SSM)-based reconstruction technique to derive a scaled, patient-specific surface model of the pelvis from a single standard anteroposterior (AP) x-ray radiograph and the feasibility of estimating the scale of the reconstructed surface model by performing a surface-based 3D/3D matching. Methods: Data sets of 14 pelvises (one plastic bone, 12 cadavers, and one patient) were used to validate the single-image based reconstruction technique. This reconstruction technique is based on a hybrid 2D/3D deformable registration process combining a landmark-to-ray registration with a SSM-based 2D/3D reconstruction. The landmark-to-ray registration was used to find an initial scale and an initial rigid transformation between the x-ray image and the SSM. The estimated scale and rigid transformation were used to initialize the SSM-based 2D/3D reconstruction. The optimal reconstruction was then achieved in three stages by iteratively matching the projections of the apparent contours extracted from a 3D model derived from the SSM to the image contours extracted from the x-ray radiograph: Iterative affine registration, statistical instantiation, and iterative regularized shape deformation. The image contours are first detected by using a semiautomatic segmentation tool based on the Livewire algorithm and then approximated by a set of sparse dominant points that are adaptively sampled from the detected contours. The unknown scales of the reconstructed models were estimated by performing a surface-based 3D/3D matching between the reconstructed models and the associated ground truth models that were derived from a CT-based reconstruction method. Such a matching also allowed for computing the errors between the reconstructed models and the associated ground truth models. Results: The technique could reconstruct the surface models of all 14 pelvises directly from the landmark

  12. Mediastinal lymph node enlargement on CT scans in idiopathic pulmonary fibrosis

    International Nuclear Information System (INIS)

    Ahn, Joong Mo; Im, Jung Gi; Yu, Kyu In; Kim, Hyeong Seog; Kim, Dae Young; Yu, Pil Mun

    1992-01-01

    The increase in size of lymph node on CT scan is the single most important finding of lymphadenopathy. The purpose of this study was to evaluate the size of mediastinal lymph nodes in patients with idiopathic pulmonary fibrosis with no evidence of malignancy or current infection. CT scans of 70 patients (16 with conventional CT and 54 with high-resolution CT) were assessed for lymph node size and location. The duration of symptoms, and the extent and pattern of the parenchymal lung disease on CT scans were correlated with lymph node enlargement. In 54 of 70 patients, more than one lymph nodes were large than 1-1.5 cm. The prevalence of node enlargement increased significant with a longer duration of symptom (p=0.001), large extent of the disease (p=0.043), and with a greater proportion of honeycomb pattern (p=0.033). Right paratracheal, subcarinal, right tracheobronchial, and paraesophageal nodes were the most common sites of node enlargement. In conclusion, mediastinal lymph node enlargement is common in patients with idiopathic pulmonary fibrosis and is more frequently seen in patients with a longer duration of clinical symptoms, greater extent of the disease, and with a larger proportion of honeycomb pattern

  13. Mediastinal lymph node enlargement on CT scans in idiopathic pulmonary fibrosis

    Energy Technology Data Exchange (ETDEWEB)

    Ahn, Joong Mo; Im, Jung Gi; Yu, Kyu In; Kim, Hyeong Seog [Seoul National University College of Medicine, Seoul (Korea, Republic of); Kim, Dae Young [Chung Buk National University College of Medicine, Chungju (Korea, Republic of); Yu, Pil Mun [Dankuk University College of Medicine, Seoul (Korea, Republic of)

    1992-09-15

    The increase in size of lymph node on CT scan is the single most important finding of lymphadenopathy. The purpose of this study was to evaluate the size of mediastinal lymph nodes in patients with idiopathic pulmonary fibrosis with no evidence of malignancy or current infection. CT scans of 70 patients (16 with conventional CT and 54 with high-resolution CT) were assessed for lymph node size and location. The duration of symptoms, and the extent and pattern of the parenchymal lung disease on CT scans were correlated with lymph node enlargement. In 54 of 70 patients, more than one lymph nodes were large than 1-1.5 cm. The prevalence of node enlargement increased significant with a longer duration of symptom (p=0.001), large extent of the disease (p=0.043), and with a greater proportion of honeycomb pattern (p=0.033). Right paratracheal, subcarinal, right tracheobronchial, and paraesophageal nodes were the most common sites of node enlargement. In conclusion, mediastinal lymph node enlargement is common in patients with idiopathic pulmonary fibrosis and is more frequently seen in patients with a longer duration of clinical symptoms, greater extent of the disease, and with a larger proportion of honeycomb pattern.

  14. Patterns for election of active computing nodes in high availability distributed data acquisition systems

    International Nuclear Information System (INIS)

    Nair, Preetha; Padmini, S.; Diwakar, M.P.; Gohel, Nilesh

    2013-01-01

    Computer based systems for power plant and research reactors are expected to have high availability. Redundancy is a common approach to improve the availability of a system. In redundant configuration the challenge is to select one node as active, and in case of failure of current active node provide automatic fast switchover by electing another node to function as active and restore normal operation. Additional constraints include: exactly one node should be elected as active in an n-way redundant architecture. This paper discusses various high availability configurations developed by Electronics Division and deployed in power and research reactors and patterns followed to elect active nodes of distributed data acquisition systems. The systems are categorized into two: Active/Passive where changeover takes effect only on the failure of Active node, and Active/Active, where changeover is effective in alternate cycles. A novel concept of priority driven state based Active (Master) node election pattern is described for Active/Passive systems which allows multiple redundancy and dynamic election of single master. The paper also discusses the Active/Active pattern, which uncovers failure early by activating all the nodes alternatively in a redundant system. This pattern can be extended to multiple redundant nodes. (author)

  15. Atomic-scale nanoindentation: detection and identification of single glide events in three dimensions by force microscopy

    International Nuclear Information System (INIS)

    Egberts, P; Bennewitz, R

    2011-01-01

    Indentation experiments on the nanometre scale have been performed by means of atomic force microscopy in ultra-high vacuum on KBr(100) surfaces. The surfaces yield in the form of discrete surface displacements with a typical length scale of 1 A. These surface displacements are detected in both normal and lateral directions. Measurement of the lateral tip displacement requires a load-dependent calibration due to the load dependence of the effective lateral compliance. Correlation of the lateral and normal displacements for each glide event allow identification of the activated slip system. The results are discussed in terms of the resolved shear stress in indentation experiments and of typical results in atomistic simulations of nanometre-scale indentation.

  16. Single and two-phase natural circulation in Westinghouse pressurized water reactor simulators: Phenomena, analysis and scaling

    International Nuclear Information System (INIS)

    Schultz, R.R.; Chapman, J.C.; Kukita, Y.; Motley, F.E.; Stumpf, H.; Chen, Y.S.; Tasaka, K.

    1987-01-01

    Natural circulation data obtained in the 1/48 scale W four loop PWR simulator - the Large Scale Test Facility (LSTF) are discussed and summarized. Core cooling modes, the primary fluid state, the primary loop mass flow and localized natural circulation phenomena occurring in the steam generator are presented. TRAC-PF1 LSTF model (using both a 1 U-tube and a 3 U-tube steam generator model) analyses of the LSTF natural circulation data including the SG recirculation patterns are presented and compared to the data. The LSTF data are then compared to similar natural circulation data obtained in the Primarkreislaufe (PKL) and the Semiscale facilities. Based on the 1/48 to 1/1705 scaling range which exists between the facilities, the implications of these data towrard natural circulation behavior in commercial plants are briefly discussed

  17. Expanded Large-Scale Forcing Properties Derived from the Multiscale Data Assimilation System and Its Application to Single-Column Models

    Science.gov (United States)

    Feng, S.; Li, Z.; Liu, Y.; Lin, W.; Toto, T.; Vogelmann, A. M.; Fridlind, A. M.

    2013-12-01

    We present an approach to derive large-scale forcing that is used to drive single-column models (SCMs) and cloud resolving models (CRMs)/large eddy simulation (LES) for evaluating fast physics parameterizations in climate models. The forcing fields are derived by use of a newly developed multi-scale data assimilation (MS-DA) system. This DA system is developed on top of the NCEP Gridpoint Statistical Interpolation (GSI) System and is implemented in the Weather Research and Forecasting (WRF) model at a cloud resolving resolution of 2 km. This approach has been applied to the generation of large scale forcing for a set of Intensive Operation Periods (IOPs) over the Atmospheric Radiation Measurement (ARM) Climate Research Facility's Southern Great Plains (SGP) site. The dense ARM in-situ observations and high-resolution satellite data effectively constrain the WRF model. The evaluation shows that the derived forcing displays accuracies comparable to the existing continuous forcing product and, overall, a better dynamic consistency with observed cloud and precipitation. One important application of this approach is to derive large-scale hydrometeor forcing and multiscale forcing, which is not provided in the existing continuous forcing product. It is shown that the hydrometeor forcing poses an appreciable impact on cloud and precipitation fields in the single-column model simulations. The large-scale forcing exhibits a significant dependency on domain-size that represents SCM grid-sizes. Subgrid processes often contribute a significant component to the large-scale forcing, and this contribution is sensitive to the grid-size and cloud-regime.

  18. Real-Time Spaceborne Synthetic Aperture Radar Float-Point Imaging System Using Optimized Mapping Methodology and a Multi-Node Parallel Accelerating Technique

    Science.gov (United States)

    Li, Bingyi; Chen, Liang; Yu, Wenyue; Xie, Yizhuang; Bian, Mingming; Zhang, Qingjun; Pang, Long

    2018-01-01

    With the development of satellite load technology and very large-scale integrated (VLSI) circuit technology, on-board real-time synthetic aperture radar (SAR) imaging systems have facilitated rapid response to disasters. A key goal of the on-board SAR imaging system design is to achieve high real-time processing performance under severe size, weight, and power consumption constraints. This paper presents a multi-node prototype system for real-time SAR imaging processing. We decompose the commonly used chirp scaling (CS) SAR imaging algorithm into two parts according to the computing features. The linearization and logic-memory optimum allocation methods are adopted to realize the nonlinear part in a reconfigurable structure, and the two-part bandwidth balance method is used to realize the linear part. Thus, float-point SAR imaging processing can be integrated into a single Field Programmable Gate Array (FPGA) chip instead of relying on distributed technologies. A single-processing node requires 10.6 s and consumes 17 W to focus on 25-km swath width, 5-m resolution stripmap SAR raw data with a granularity of 16,384 × 16,384. The design methodology of the multi-FPGA parallel accelerating system under the real-time principle is introduced. As a proof of concept, a prototype with four processing nodes and one master node is implemented using a Xilinx xc6vlx315t FPGA. The weight and volume of one single machine are 10 kg and 32 cm × 24 cm × 20 cm, respectively, and the power consumption is under 100 W. The real-time performance of the proposed design is demonstrated on Chinese Gaofen-3 stripmap continuous imaging. PMID:29495637

  19. Stand dynamics following gap-scale exogenous disturbance in a single cohort mixed species stand in Morgan County, Tennessee

    Science.gov (United States)

    Brian S. Hughett; Wayne K. Clatterbuck

    2014-01-01

    Differences in composition, structure, and growth under canopy gaps created by the mortality of a single stem were analyzed using analysis of variance under two scenarios, with stem removed or with stem left as a standing snag. There were no significant differences in composition and structure of large diameter residual stems within upper canopy strata. Some...

  20. Single hadron response measurement and calorimeter jet energy scale uncertainty with the ATLAS detector at the LHC

    NARCIS (Netherlands)

    Aad, G.; et al., [Unknown; Bentvelsen, S.; Berglund, E.; Bobbink, G.J.; Bos, K.; Boterenbrood, H.; Colijn, A.P.; de Jong, P.; de Nooij, L.; Deviveiros, P.O.; Doxiadis, A.D.; Ferrari, P.; Garitaonandia, H.; Geerts, D.A.A.; Gosselink, M.; Hartjes, F.; Hessey, N.P.; Igonkina, O.; Kayl, M.S.; Klous, S.; Kluit, P.; Koffeman, E.; Lee, H.; Lenz, T.; Linde, F.; Luijckx, G.; Massaro, G.; Mechnich, J.; Mussche, I.; Ottersbach, J.P.; Reichold, A.; Rijpstra, M.; Ruckstuhl, N.; Snuverink, J.; Ta, D.; Tsiakiris, M.; Turlay, E.; van der Graaf, H.; van der Kraaij, E.; van der Leeuw, R.; van der Poel, E.; van Kesteren, Z.; van Vulpen, I.; Verkerke, W.; Vermeulen, J.C.; Vranjes Milosavljevic, M.; Vreeswijk, M.

    2013-01-01

    The uncertainty on the calorimeter energy response to jets of particles is derived for the ATLAS experiment at the Large Hadron Collider (LHC). First, the calorimeter response to single isolated charged hadrons is measured and compared to the Monte Carlo simulation using proton-proton collisions at

  1. SEU Prediction from SET modeling using multi-node collection in bulk transistors and SRAMs down to the 65 nm technology node

    International Nuclear Information System (INIS)

    Artola, L.; Hubert, G.; Duzellier, S.; Artola, L.; Bezerra, F.; Warren, K.M.; Massengill, L.W.; Gaillardin, M.; Paillet, Ph.; Raine, M.; Girard, S.; Schrimpf, R.D.; Reed, R.A.; Weller, R.A.; Ahlbin, J.R.

    2011-01-01

    A new methodology of prediction for SEU is proposed based on SET modeling. The modeling of multi-node charge collection is performed using the ADDICT model for predicting single event transients and upsets in bulk transistors and SRAMs down to 65 nm. The predicted single event upset cross sections agree well with experimental data for SRAMs. (authors)

  2. Opinion formation driven by PageRank node influence on directed networks

    Science.gov (United States)

    Eom, Young-Ho; Shepelyansky, Dima L.

    2015-10-01

    We study a two states opinion formation model driven by PageRank node influence and report an extensive numerical study on how PageRank affects collective opinion formations in large-scale empirical directed networks. In our model the opinion of a node can be updated by the sum of its neighbor nodes' opinions weighted by the node influence of the neighbor nodes at each step. We consider PageRank probability and its sublinear power as node influence measures and investigate evolution of opinion under various conditions. First, we observe that all networks reach steady state opinion after a certain relaxation time. This time scale is decreasing with the heterogeneity of node influence in the networks. Second, we find that our model shows consensus and non-consensus behavior in steady state depending on types of networks: Web graph, citation network of physics articles, and LiveJournal social network show non-consensus behavior while Wikipedia article network shows consensus behavior. Third, we find that a more heterogeneous influence distribution leads to a more uniform opinion state in the cases of Web graph, Wikipedia, and Livejournal. However, the opposite behavior is observed in the citation network. Finally we identify that a small number of influential nodes can impose their own opinion on significant fraction of other nodes in all considered networks. Our study shows that the effects of heterogeneity of node influence on opinion formation can be significant and suggests further investigations on the interplay between node influence and collective opinion in networks.

  3. Lymphoscintigraphic diagnosis of the lymph node metastasis of esophageal cancer

    International Nuclear Information System (INIS)

    Terui, Shoji; Kawai, Hideo; Hirashima, Toshio; Yamaguchi, Hajime; Kato, Hoichi; Iizuka, Norifumi

    1985-01-01

    Lymphoscintigraphy with 99m Tc-labeled rhenium sulfur colloid was performed preoperatively in 30 patients with esopohageal cancer. It showed hot nodes in a total of 267 lymph nodes, 176 mediastinal nodes and 91 celiac artery nodes. Of these 267 nodes, 47 (18 %) were found to have metastasis, including 34 (19 %) mediastinal nodes and 13 (14 %) celiac artery nodes. On the other hand, the number of non-visualized lymph nodes (cold nodes) was 542. Of them, 78 (14 %) had metastasis; 46 (15 %) were mediastinal nodes and 32 (14 %) were celiac artery nodes. (Namekawa, K.)

  4. Lambda network having 2.sup.m-1 nodes in each of m stages with each node coupled to four other nodes for bidirectional routing of data packets between nodes

    Science.gov (United States)

    Napolitano, Jr., Leonard M.

    1995-01-01

    The Lambda network is a single stage, packet-switched interprocessor communication network for a distributed memory, parallel processor computer. Its design arises from the desired network characteristics of minimizing mean and maximum packet transfer time, local routing, expandability, deadlock avoidance, and fault tolerance. The network is based on fixed degree nodes and has mean and maximum packet transfer distances where n is the number of processors. The routing method is detailed, as are methods for expandability, deadlock avoidance, and fault tolerance.

  5. The sentinel lymph node spread determines quantitatively melanoma seeding to non-sentinel lymph nodes and survival.

    Science.gov (United States)

    Ulmer, Anja; Dietz, Klaus; Werner-Klein, Melanie; Häfner, Hans-Martin; Schulz, Claudia; Renner, Philipp; Weber, Florian; Breuninger, Helmut; Röcken, Martin; Garbe, Claus; Fierlbeck, Gerhard; Klein, Christoph A

    2018-03-01

    Complete lymph node dissection (CLND) after a positive sentinel node (SN) biopsy provides important prognostic information in melanoma patients but has been questioned for therapeutic use recently. We explored whether quantification of the tumour spread to SNs may replace histopathology of non-sentinel nodes (NSNs) for staging purposes. We quantified melanoma spread in SNs and NSNs in 128 patients undergoing CLND for a positive SN. In addition to routine histopathology, one-half of each of all 1496 SNs and NSNs was disaggregated into a single cell suspension and stained immunocytochemically to determine the number of melanoma cells per 10 6 lymph node cells, i.e. the disseminated cancer cell density (DCCD). We uncovered melanoma spread to NSNs in the majority of patients; however, the tumour load and the proportion of positive nodes were significantly lower in NSNs than in SNs. The relation between SN and NSN spread could be described by a mathematical function with DCCD NSN  = DCCD SN c /10 1 - c (c = 0.69; 95% confidence interval [CI]: 0.62-0.76). At a median follow-up of 67 months, multivariable Cox regression analyses revealed that DCCD SN (p = 0.02; HR 1.34, 95% CI: 1.05-1.71) and the total number of pathologically positive nodes (p = 0.02; HR 1.53, 95% CI: 1.07-2.22) were significant risk factors after controlling for age, gender, thickness of melanoma and ulceration status. A prognostic model based on DCCD SN and melanoma thickness predicted outcome as accurately as a model including pathological information of both SNs and NSNs. The assessment of DCCD SN renders CLND for staging purposes unnecessary. Copyright © 2017 Elsevier Ltd. All rights reserved.

  6. Localizing and placement of network node functions in a network

    NARCIS (Netherlands)

    Strijkers, R.J.; Meulenhoff, P.J.

    2014-01-01

    The invention enables placement and use of a network node function in a second network node instead of using the network node function in a first network node. The network node function is e.g. a server function or a router function. The second network node is typically located in or close to the

  7. Investigations on heavy ion induced Single-Event Transients (SETs) in highly-scaled FinFETs

    Energy Technology Data Exchange (ETDEWEB)

    Gaillardin, M., E-mail: marc.gaillardin@cea.fr [CEA, DAM, DIF, F-91297 Arpajon (France); Raine, M.; Paillet, P. [CEA, DAM, DIF, F-91297 Arpajon (France); Adell, P.C. [Jet Propulsion Laboratory, Pasadena, CA 91101 (United States); Girard, S. [Université de Saint-Etienne, Laboratoire H. Curien, UMR-5516, 42000 Saint-Etienne (France); Duhamel, O. [CEA, DAM, DIF, F-91297 Arpajon (France); Andrieu, F.; Barraud, S.; Faynot, O. [CEA, LETI-Minatec, 17 avenue des Martyrs, 38000 Grenoble (France)

    2015-12-15

    We investigate Single-Event Transients (SET) in different designs of multiple-gate devices made of FinFETs with various geometries. Heavy ion experimental results are explained by using a thorough charge collection analysis of fast transients measured on dedicated test structures. Multi-level simulations are performed to get new insights into the charge collection mechanisms in multiple-gate devices. Implications for multiple-gate device design hardening are finally discussed.

  8. Electron beam mask writer EBM-9500 for logic 7nm node generation

    Science.gov (United States)

    Matsui, Hideki; Kamikubo, Takashi; Nakahashi, Satoshi; Nomura, Haruyuki; Nakayamada, Noriaki; Suganuma, Mizuna; Kato, Yasuo; Yashima, Jun; Katsap, Victor; Saito, Kenichi; Kobayashi, Ryoei; Miyamoto, Nobuo; Ogasawara, Munehiro

    2016-10-01

    Semiconductor scaling is slowing down because of difficulties of device manufacturing below logic 7nm node generation. Various lithography candidates which include ArF immersion with resolution enhancement technology (like Inversed Lithography technology), Extreme Ultra Violet lithography and Nano Imprint lithography are being developed to address the situation. In such advanced lithography, shot counts of mask patterns are estimated to increase explosively in critical layers, and then it is hoped that multi beam mask writer (MBMW) is released to handle them within realistic write time. However, ArF immersion technology with multiple patterning will continue to be a mainstream lithography solution for most of the layers. Then, the shot counts in less critical layers are estimated to be stable because of the limitation of resolution in ArF immersion technology. Therefore, single beam mask writer (SBMW) can play an important role for mask production still, relative to MBMW. Also the demand of SBMW seems actually strong for the logic 7nm node. To realize this, we have developed a new SBMW, EBM-9500 for mask fabrication in this generation. A newly introduced electron beam source enables higher current density of 1200A/cm2. Heating effect correction function has also been newly introduced to satisfy the requirements for both pattern accuracy and throughput. In this paper, we will report the configuration and performance of EBM-9500.

  9. Single benign metastasising leiomyoma of an inguinal lymph node.

    NARCIS (Netherlands)

    Laban, KG; Tobon-Morales, Roberto; Hodge, Janice; Schreuder, HWR

    2016-01-01

    Benign metastasising leiomyoma (BML) is a rare benign disease associated with uterine leiomyoma and history of uterine surgery. It most frequently occurs in premenopausal woman, with a pulmonary localisation, and consisting of multiple nodules. We present an uncommon case of a 69-year-old woman with

  10. Uptake kinetics of relatively insoluble particles by tracheobronchial lymph nodes

    International Nuclear Information System (INIS)

    Thomas, R.G.

    1976-01-01

    Tracheobronchial lymph nodes accumulate a portion of material deposited in the deep lung following inhalation of relatively insoluble particles. Experiments involving a variety of compounds, inhaled singly or repeatedly, indicate that the kinetics of lymph node uptake are fairly independent of particle characteristics and mammalian species. The buildup per unit weight of nodal tissue compared with that of lung tissue, with time, can be represented by a linear logarithmic function. However, since the scatter in experimental points may be large at any given time after inhalation exposure, a number of different kinetic descriptions of uptake can be derived. The logarithmic pattern of accumulation can be approximated over an extended time range (several years) by use of a combination of first-order kinetics of loss from the lung and of buildup in lymph nodes, but it is recognized that the processes are much more complicated than this treatment would indicate. Clearance (loss) from the lymph nodes is not well defined, but this aspect is discussed in light of the kinetic models presented

  11. The hidden sentinel node in breast cancer

    International Nuclear Information System (INIS)

    Tanis, P.J.; Sandick, J.W. van; Nieweg, O.E.; Rutgers, E.J.T.; Kroon, B.B.R.; Valdes Olmos, R.A.; Hoefnagel, C.A.

    2002-01-01

    The purpose of this study was to analyse the occurrence of non-visualisation during preoperative lymphoscintigraphy for sentinel node identification in breast cancer. Preoperative lymphoscintigraphy was performed in 495 clinically node-negative breast cancer patients (501 sentinel node procedures) after injection of technetium-99m nanocolloid. Anterior and prone lateral (hanging breast) planar images were obtained a few minutes and 4 h after injection. The sentinel node was intraoperatively identified with the aid of patent blue dye and a gamma-ray detection probe. A sentinel node was visualised on the 4-h images in 449 of 501 procedures (90%). This visualisation rate improved from 76% to 94% during the study period. Delayed imaging (5-23 h) in 19 patients whose sentinel nodes failed to show, resulted in visualisation in four of them. A repeat injection of radiocolloid in 11 patients revealed a sentinel node in six. In the end, the visualisation rate was 92%. The sentinel node was surgically retrieved in 24 of the remaining 42 patients with non-visualisation (57%). Sentinel nodes that were visualised were tumour-positive in 38% and non-visualised sentinel nodes were involved in 50% (χ 2 , P=0.17). In a multivariate regression analysis, scintigraphic non-visualisation was independently associated with increased patient age (P<0.001), decreased tracer dose (P<0.001) and increased number of tumour-positive lymph nodes (P=0.013). The use of a sufficient amount of radioactivity (at least 100 MBq) is recommended for lymphatic mapping in breast cancer, especially in elderly women. Delayed imaging and re-injection of the radioactive tracer increase the visualisation rate. The non-visualised sentinel node can be identified intraoperatively in more than half of the patients. (orig.)

  12. The hidden sentinel node in breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Tanis, P.J.; Sandick, J.W. van; Nieweg, O.E.; Rutgers, E.J.T.; Kroon, B.B.R. [Department of Surgery, Netherlands Cancer Institute, Amsterdam (Netherlands); Valdes Olmos, R.A.; Hoefnagel, C.A. [Department of Nuclear Medicine, Netherlands Cancer Institute, Amsterdam (Netherlands)

    2002-03-01

    The purpose of this study was to analyse the occurrence of non-visualisation during preoperative lymphoscintigraphy for sentinel node identification in breast cancer. Preoperative lymphoscintigraphy was performed in 495 clinically node-negative breast cancer patients (501 sentinel node procedures) after injection of technetium-99m nanocolloid. Anterior and prone lateral (hanging breast) planar images were obtained a few minutes and 4 h after injection. The sentinel node was intraoperatively identified with the aid of patent blue dye and a gamma-ray detection probe. A sentinel node was visualised on the 4-h images in 449 of 501 procedures (90%). This visualisation rate improved from 76% to 94% during the study period. Delayed imaging (5-23 h) in 19 patients whose sentinel nodes failed to show, resulted in visualisation in four of them. A repeat injection of radiocolloid in 11 patients revealed a sentinel node in six. In the end, the visualisation rate was 92%. The sentinel node was surgically retrieved in 24 of the remaining 42 patients with non-visualisation (57%). Sentinel nodes that were visualised were tumour-positive in 38% and non-visualised sentinel nodes were involved in 50% ({chi}{sup 2}, P=0.17). In a multivariate regression analysis, scintigraphic non-visualisation was independently associated with increased patient age (P<0.001), decreased tracer dose (P<0.001) and increased number of tumour-positive lymph nodes (P=0.013). The use of a sufficient amount of radioactivity (at least 100 MBq) is recommended for lymphatic mapping in breast cancer, especially in elderly women. Delayed imaging and re-injection of the radioactive tracer increase the visualisation rate. The non-visualised sentinel node can be identified intraoperatively in more than half of the patients. (orig.)

  13. Gammascintigraphy of metastases of the lymph nodes

    International Nuclear Information System (INIS)

    Mechev, D.S.; Shishkina, V.V.

    1985-01-01

    It was indicated that according to the degree of informative value all the methods used in this study can be listed as follows: the method of combined use of positive and negative scintigraphy, the method of positive scintigraphy with Ga 67 -citrate (the tymph nodes above the diagram) and Tc 99 -pertechnate (the lymph nodes below the diaphragm), the method of indirect radionuclide lymphography with colloids. The main indices of radionuclide methods in the diagnosis of the lymph node metastatic involvement are presented

  14. A Low Power IoT Sensor Node Architecture for Waste Management Within Smart Cities Context.

    Science.gov (United States)

    Cerchecci, Matteo; Luti, Francesco; Mecocci, Alessandro; Parrino, Stefano; Peruzzi, Giacomo; Pozzebon, Alessandro

    2018-04-21

    This paper focuses on the realization of an Internet of Things (IoT) architecture to optimize waste management in the context of Smart Cities. In particular, a novel typology of sensor node based on the use of low cost and low power components is described. This node is provided with a single-chip microcontroller, a sensor able to measure the filling level of trash bins using ultrasounds and a data transmission module based on the LoRa LPWAN (Low Power Wide Area Network) technology. Together with the node, a minimal network architecture was designed, based on a LoRa gateway, with the purpose of testing the IoT node performances. Especially, the paper analyzes in detail the node architecture, focusing on the energy saving technologies and policies, with the purpose of extending the batteries lifetime by reducing power consumption, through hardware and software optimization. Tests on sensor and radio module effectiveness are also presented.

  15. A Low Power IoT Sensor Node Architecture for Waste Management Within Smart Cities Context

    Directory of Open Access Journals (Sweden)

    Matteo Cerchecci

    2018-04-01

    Full Text Available This paper focuses on the realization of an Internet of Things (IoT architecture to optimize waste management in the context of Smart Cities. In particular, a novel typology of sensor node based on the use of low cost and low power components is described. This node is provided with a single-chip microcontroller, a sensor able to measure the filling level of trash bins using ultrasounds and a data transmission module based on the LoRa LPWAN (Low Power Wide Area Network technology. Together with the node, a minimal network architecture was designed, based on a LoRa gateway, with the purpose of testing the IoT node performances. Especially, the paper analyzes in detail the node architecture, focusing on the energy saving technologies and policies, with the purpose of extending the batteries lifetime by reducing power consumption, through hardware and software optimization. Tests on sensor and radio module effectiveness are also presented.

  16. A Low Power IoT Sensor Node Architecture for Waste Management Within Smart Cities Context

    Science.gov (United States)

    Cerchecci, Matteo; Luti, Francesco; Mecocci, Alessandro; Parrino, Stefano; Peruzzi, Giacomo

    2018-01-01

    This paper focuses on the realization of an Internet of Things (IoT) architecture to optimize waste management in the context of Smart Cities. In particular, a novel typology of sensor node based on the use of low cost and low power components is described. This node is provided with a single-chip microcontroller, a sensor able to measure the filling level of trash bins using ultrasounds and a data transmission module based on the LoRa LPWAN (Low Power Wide Area Network) technology. Together with the node, a minimal network architecture was designed, based on a LoRa gateway, with the purpose of testing the IoT node performances. Especially, the paper analyzes in detail the node architecture, focusing on the energy saving technologies and policies, with the purpose of extending the batteries lifetime by reducing power consumption, through hardware and software optimization. Tests on sensor and radio module effectiveness are also presented. PMID:29690552

  17. Advanced Control Strategies to Enable a More Wide-Scale Adoption of Single-Phase Photovoltaic Systems

    DEFF Research Database (Denmark)

    Yang, Yongheng

    , a thorough evaluation of those topologies in terms of e.g. efficiency, reliability, leakage current mitigation ability, and reactive power injection capability has been presented in Chapter 3, where a multidisciplinary assessment approach with characterized features of energy production estimation...... and lifetime prediction based on mission profiles (e.g. solar irradiance level and ambient temperature) has been proposed. Grid detection and synchronization techniques have also been discussed in Chapter 2, since they are of importance in the control of single-phase systems both in normal operation mode...

  18. A wireless laser displacement sensor node for structural health monitoring.

    Science.gov (United States)

    Park, Hyo Seon; Kim, Jong Moon; Choi, Se Woon; Kim, Yousok

    2013-09-30

    This study describes a wireless laser displacement sensor node that measures displacement as a representative damage index for structural health monitoring (SHM). The proposed measurement system consists of a laser displacement sensor (LDS) and a customized wireless sensor node. Wireless communication is enabled by a sensor node that consists of a sensor module, a code division multiple access (CDMA) communication module, a processor, and a power module. An LDS with a long measurement distance is chosen to increase field applicability. For a wireless sensor node driven by a battery, we use a power control module with a low-power processor, which facilitates switching between the sleep and active modes, thus maximizing the power consumption efficiency during non-measurement and non-transfer periods. The CDMA mode is also used to overcome the limitation of communication distance, which is a challenge for wireless sensor networks and wireless communication. To evaluate the reliability and field applicability of the proposed wireless displacement measurement system, the system is tested onsite to obtain the required vertical displacement measurements during the construction of mega-trusses and an edge truss, which are the primary structural members in a large-scale irregular building currently under construction. The measurement values confirm the validity of the proposed wireless displacement measurement system and its potential for use in safety evaluations of structural elements.

  19. Autonomous solutions for powering wireless sensor nodes in rivers

    Science.gov (United States)

    Kamenar, E.; Maćešić, S.; Gregov, G.; Blažević, D.; Zelenika, S.; Marković, K.; Glažar, V.

    2015-05-01

    There is an evident need for monitoring pollutants and/or other conditions in river flows via wireless sensor networks. In a typical wireless sensor network topography, a series of sensor nodes is to be deployed in the environment, all wirelessly connected to each other and/or their gateways. Each sensor node is composed of active electronic devices that have to be constantly powered. In general, batteries can be used for this purpose, but problems may occur when they have to be replaced. In the case of large networks, when sensor nodes can be placed in hardly accessible locations, energy harvesting can thus be a viable powering solution. The possibility to use three different small-scale river flow energy harvesting principles is hence thoroughly studied in this work: a miniaturized underwater turbine, a so-called `piezoelectric eel' and a hybrid turbine solution coupled with a rigid piezoelectric beam. The first two concepts are then validated experimentally in laboratory as well as in real river conditions. The concept of the miniaturised hydro-generator is finally embedded into the actual wireless sensor node system and its functionality is confirmed.

  20. A Wireless Laser Displacement Sensor Node for Structural Health Monitoring

    Directory of Open Access Journals (Sweden)

    Se Woon Choi

    2013-09-01

    Full Text Available This study describes a wireless laser displacement sensor node that measures displacement as a representative damage index for structural health monitoring (SHM. The proposed measurement system consists of a laser displacement sensor (LDS and a customized wireless sensor node. Wireless communication is enabled by a sensor node that consists of a sensor module, a code division multiple access (CDMA communication module, a processor, and a power module. An LDS with a long measurement distance is chosen to increase field applicability. For a wireless sensor node driven by a battery, we use a power control module with a low-power processor, which facilitates switching between the sleep and active modes, thus maximizing the power consumption efficiency during non-measurement and non-transfer periods. The CDMA mode is also used to overcome the limitation of communication distance, which is a challenge for wireless sensor networks and wireless communication. To evaluate the reliability and field applicability of the proposed wireless displacement measurement system, the system is tested onsite to obtain the required vertical displacement measurements during the construction of mega-trusses and an edge truss, which are the primary structural members in a large-scale irregular building currently under construction. The measurement values confirm the validity of the proposed wireless displacement measurement system and its potential for use in safety evaluations of structural elements.

  1. Energy-Aware Topology Evolution Model with Link and Node Deletion in Wireless Sensor Networks

    Directory of Open Access Journals (Sweden)

    Xiaojuan Luo

    2012-01-01

    Full Text Available Based on the complex network theory, a new topological evolving model is proposed. In the evolution of the topology of sensor networks, the energy-aware mechanism is taken into account, and the phenomenon of change of the link and node in the network is discussed. Theoretical analysis and numerical simulation are conducted to explore the topology characteristics and network performance with different node energy distribution. We find that node energy distribution has the weak effect on the degree distribution P(k that evolves into the scale-free state, nodes with more energy carry more connections, and degree correlation is nontrivial disassortative. Moreover, the results show that, when nodes energy is more heterogeneous, the network is better clustered and enjoys higher performance in terms of the network efficiency and the average path length for transmitting data.

  2. Lymphoscintigraphic sentinel node identification in patients with breast cancer: the role of SPECT-CT

    International Nuclear Information System (INIS)

    Lerman, H.; Metser, U.; Lievshitz, G.; Sperber, F.; Shneebaum, S.; Even-Sapir, E.

    2006-01-01

    Lymph node status is a major factor in determining the stage, appropriate therapy and outcome in patients with breast cancer. It is therefore of clinical importance to accurately identify all sentinel nodes (SNs) for each individual tumour before surgery. The purpose of this study was to assess the role of SPECT-CT lymphoscintigraphy in SN identification in patients with breast cancer. Lymphoscintigraphy comprising planar and SPECT-CT acquisition was performed in 157 consecutive patients with breast cancer (mean age 54.7±10.6, range 27-81 years) with a palpable mass (n=100), with a non-palpable mass (n=52) or post lumpectomy (n=5). Planar and SPECT-CT images were interpreted separately and the two imaging techniques were compared with respect to their ability to identify hot nodes. Planar imaging alone was negative for identification of hot nodes in 15% of the patients. SPECT-CT alone was negative in 10% and both techniques were negative in 9% of the patients. Forty-six of the total of 361 (13%) hot nodes identified by lymphoscintigraphy were detected only on SPECT-CT, including 21 nodes obscured by the scattered radiation from the injection site, nine adjacent nodes misinterpreted on planar images as a single node and 16 nodes which were missed on planar images and detected on SPECT data. SPECT-CT detected additional sites of drainage unexpected on planar images, including axillary (n=23 patients), internal mammary (n=5 patients), interpectoral (n=3 patients) and intramammary (n=2 patients) lymph node sites. Fourteen of the 329 (4%) hot lesions seen on planar images were false positive non-nodal sites of uptake that were accurately assessed by SPECT-CT and further validated by surgery. In a single patient, SPECT-CT was negative while planar images identified the SN. (orig.)

  3. Sentinel node concept in breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Kiricuta, I.C. [St. Vincenz-Hospital, Limburg (Germany). Inst. for Radiation Oncology

    2000-07-01

    Background/purpose: It seems that there exists a specific lymph node center called sentinel node (SN) which appears to be the primary site of metastases. The sentinel node concept (SNC) is fundamentally based on the orderly progression of tumor cells within the lymphatic system. It is the most important new concept in surgical and radiation oncology. The purpose is to present the biological significance, the diagnostic and clinical basis of the sentinel node concept in breast cancer patients. Material and methods: Lymphoscintigraphy and gamma probe biopsy is necessary to show predictable lymph flow to the regional sentinel node, to multiple sentinel nodes or unpredictable lymph flow to extra-regional sentinel nodes and for performing sentinel node procedure. The standard protocol for the evaluation of the sentinel node metastases consists of extensive histopathological investigation including step Hematoxylin and Eosin (H and E) stained sections and immunohistochemistry. Results: A high rate of success of the identification of the sentinel node for breast cancer was reported. The presence or absence of metastasis in this node is a very accurate predictor of overall nodal status. The temptation to examine the sentinel node with the greatest possible degree of accuracy highlights one of the major problems related to sentinel node biopsy. The success of the sentinel node procedure depends primarily on the adequate functional capacity necessary for sufficient uptake to ensure the accurate identification. In negative sentinel-node patients a complete axillary lymph node dissection is avoidable. In sentinel-node positive patients and clinically negative patients a postoperative radiotherapy would permit an adequate tumor control. The last 2-procedures permit a low morbidity. In the actual TNM classification it was recently introduced a definition of a 'pN0' patient based on sentinel node biopsy. New target volumes are defined for adjuvant radiotherapy or

  4. Overlapping double potential wells in a single optical microtube cavity with vernier-scale-like tuning effect

    Energy Technology Data Exchange (ETDEWEB)

    Madani, A.; Schmidt, O. G. [Institute for Integrative Nanosciences, IFW Dresden, Helmholtzstr. 20, 01069 Dresden (Germany); Material Systems for Nanoelectronics, Chemnitz University of Technology, Reichenhainer Str. 70, 09107 Chemnitz (Germany); Bolaños Quiñones, V. A.; Ma, L. B., E-mail: l.ma@ifw-dresden.de; Jorgensen, M. R. [Institute for Integrative Nanosciences, IFW Dresden, Helmholtzstr. 20, 01069 Dresden (Germany); Miao, S. D. [Anhui Key Lab of Controllable Chemical Reaction and Material Chemical Engineering, School of Chemical Engineering, Hefei University of Technology, Tunxi Road. 193, Hefei, Anhui 230009 (China)

    2016-04-25

    Spatially and temporally overlapping double potential wells are realized in a hybrid optical microtube cavity due to the coexistence of an aggregate of luminescent quantum dots embedded in the tube wall and the cone-shaped tube's geometry. The double potential wells produce two independent sets of optical modes with different sets of mode numbers, indicating phase velocity separation for the modes overlapping at the same frequency. The overlapping mode position can be tuned by modifying the tube cavity, where these mode sets shift with different magnitudes, allowing for a vernier-scale-like tuning effect.

  5. Overlapping double potential wells in a single optical microtube cavity with vernier-scale-like tuning effect

    International Nuclear Information System (INIS)

    Madani, A.; Schmidt, O. G.; Bolaños Quiñones, V. A.; Ma, L. B.; Jorgensen, M. R.; Miao, S. D.

    2016-01-01

    Spatially and temporally overlapping double potential wells are realized in a hybrid optical microtube cavity due to the coexistence of an aggregate of luminescent quantum dots embedded in the tube wall and the cone-shaped tube's geometry. The double potential wells produce two independent sets of optical modes with different sets of mode numbers, indicating phase velocity separation for the modes overlapping at the same frequency. The overlapping mode position can be tuned by modifying the tube cavity, where these mode sets shift with different magnitudes, allowing for a vernier-scale-like tuning effect.

  6. Atom-scale covalent electrochemical modification of single-layer graphene on SiC substrates by diaryliodonium salts

    International Nuclear Information System (INIS)

    Gearba, Raluca I.; Mueller, Kory M.; Veneman, Peter A.; Holliday, Bradley J.; Chan, Calvin K.; Stevenson, Keith J.

    2015-01-01

    Owing to its high conductivity, graphene holds promise as an electrode for energy devices such as batteries and photovoltaics. However, to this end, the work function and doping levels in graphene need to be precisely tuned. One promising route for modifying graphene's electronic properties is via controlled covalent electrochemical grafting of molecules. We show that by employing diaryliodonium salts instead of the commonly used diazonium salts, spontaneous functionalization is avoided. This then allows for precise tuning of the grafting density. Moreover, by employing bis(4-nitrophenyl)iodonium(III) tetrafluoroborate (DNP) salt calibration curves, the surface functionalization density (coverage) of glassy carbon was controlled using cyclic voltammetry in varying salt concentrations. These electro-grafting conditions and calibration curves translated directly over to modifying single layer epitaxial graphene substrates (grown on insulating 6H-SiC (0 0 0 1)). In addition to quantifying the functionalization densities using electrochemical methods, samples with low grafting densities were characterized by low-temperature scanning tunneling microscopy (LT-STM). We show that the use of buffer-layer free graphene substrates is required for clear observation of the nitrophenyl modifications. Furthermore, atomically-resolved STM images of single site modifications were obtained, showing no preferential grafting at defect sites or SiC step edges as supposed previously in the literature. Most of the grafts exhibit threefold symmetry, but occasional extended modifications (larger than 4 nm) were observed as well

  7. Benchmark of AC and DC active power decoupling circuits for second-order harmonic mitigation in kW-scale single-phase inverters

    DEFF Research Database (Denmark)

    Qin, Zian; Tang, Yi; Loh, Poh Chiang

    2015-01-01

    studied, where the commercially available film capacitors, circuit topologies, and control strategies for active power decoupling are all taken into account. Then, an adaptive decoupling voltage control method is proposed to further improve the performance of dc decoupling in terms of efficiency...... and reliability. The feasibility and superiority of the identified solution for active power decoupling together with the proposed adaptive decoupling voltage control method are finally verified by both the experimental results obtained on a 2 kW single-phase inverter.......This paper presents the benchmark study of ac and dc active power decoupling circuits for second-order harmonic mitigation in kW-scale single-phase inverters. First of all, the best solutions of active power decoupling to achieve high efficiency and power density are identified and comprehensively...

  8. Sentinel Node Biopsy Alone versus Completion Axillary Node Dissection in Node Positive Breast Cancer: Systematic Review and Meta-Analysis

    Directory of Open Access Journals (Sweden)

    Rachna Ram

    2014-01-01

    Full Text Available Introduction. There has been recent interest in validity of completion axillary node dissection after a positive sentinel node. This systematic review aims to ascertain if sentinel lymph node dissection alone was noninferior to axillary lymph node dissection for breast cancer patients who have a positive sentinel node. Method. A systematic review of the electronic databases Embase, MEDLINE, and Cochrane Register of Controlled Trials was carried out. Only randomised trials that had patients with positive sentinel node as the study sample were included in the meta-analysis using the reported hazard ratios with a fixed effect model. Results. Three randomised controlled trials and five retrospective studies were identified. The pooled effect for overall survival was HR 0.94, 95% CI [0.79, 1.19], and for disease free survival was HR 0.83, 95% CI [0.60, 1.14]. The reported rates for locoregional recurrence were similar in both groups. The surgical morbidity was found to be significantly more in patients who had underwent axillary dissection. Conclusion. Amongst patients with micrometastasis in the sentinel node, no further axillary dissection is necessary. For patients with macrometastasis in the sentinel node, it is reasonable to consider omitting axillary dissection to avoid the morbidity of the procedure.

  9. Node-making process in network meta-analysis of nonpharmacological treatment are poorly reported.

    Science.gov (United States)

    James, Arthur; Yavchitz, Amélie; Ravaud, Philippe; Boutron, Isabelle

    2018-05-01

    To identify methods to support the node-making process in network meta-analyses (NMAs) of nonpharmacological treatments. We proceeded in two stages. First, we conducted a literature review of guidelines and methodological articles about NMAs to identify methods proposed to lump interventions into nodes. Second, we conducted a systematic review of NMAs of nonpharmacological treatments to extract methods used by authors to support their node-making process. MEDLINE and Google Scholar were searched to identify articles assessing NMA guidelines or methodology intended for NMA authors. MEDLINE, CENTRAL, and EMBASE were searched to identify reports of NMAs including at least one nonpharmacological treatment. Both searches involved articles available from database inception to March 2016. From the methodological review, we identified and extracted methods proposed to lump interventions into nodes. From the systematic review, the reporting of the network was assessed as long as the method described supported the node-making process. Among the 116 articles retrieved in the literature review, 12 (10%) discussed the concept of lumping or splitting interventions in NMAs. No consensual method was identified during the methodological review, and expert consensus was the only method proposed to support the node-making process. Among 5187 references for the systematic review, we included 110 reports of NMAs published between 2007 and 2016. The nodes were described in the introduction section of 88 reports (80%), which suggested that the node content might have been a priori decided before the systematic review. Nine reports (8.1%) described a specific process or justification to build nodes for the network. Two methods were identified: (1) fit a previously published classification and (2) expert consensus. Despite the importance of NMA in the delivery of evidence when several interventions are available for a single indication, recommendations on the reporting of the node

  10. Occult Pelvic Lymph Node Involvement in Bladder Cancer: Implications for Definitive Radiation

    Energy Technology Data Exchange (ETDEWEB)

    Goldsmith, Benjamin; Baumann, Brian C.; He, Jiwei; Tucker, Kai; Bekelman, Justin; Deville, Curtiland; Vapiwala, Neha [Department of Radiation Oncology, Hospital of the University of Pennsylvania, Philadelphia, Pennsylvania (United States); Vaughn, David; Keefe, Stephen M. [Department of Medical Oncology, Hospital of the University of Pennsylvania, Philadelphia, Pennsylvania (United States); Guzzo, Thomas; Malkowicz, S. Bruce [Department of Urology, Hospital of the University of Pennsylvania, Philadelphia, Pennsylvania (United States); Christodouleas, John P., E-mail: christojo@uphs.upenn.edu [Department of Radiation Oncology, Hospital of the University of Pennsylvania, Philadelphia, Pennsylvania (United States)

    2014-03-01

    Purpose: To inform radiation treatment planning for clinically staged, node-negative bladder cancer patients by identifying clinical factors associated with the presence and location of occult pathologic pelvic lymph nodes. Methods and Materials: The records of patients with clinically staged T1-T4N0 urothelial carcinoma of the bladder undergoing radical cystectomy and pelvic lymphadenectomy at a single institution were reviewed. Logistic regression was used to evaluate associations between preoperative clinical variables and occult pathologic pelvic or common iliac lymph nodes. Percentages of patient with involved lymph node regions entirely encompassed within whole bladder (perivesicular nodal region), small pelvic (perivesicular, obturator, internal iliac, and external iliac nodal regions), and extended pelvic clinical target volume (CTV) (small pelvic CTV plus common iliac regions) were calculated. Results: Among 315 eligible patients, 81 (26%) were found to have involved pelvic lymph nodes at the time of surgery, with 38 (12%) having involved common iliac lymph nodes. Risk of occult pathologically involved lymph nodes did not vary with clinical T stage. On multivariate analysis, the presence of lymphovascular invasion (LVI) on preoperative biopsy was significantly associated with occult pelvic nodal involvement (odds ratio 3.740, 95% confidence interval 1.865-7.499, P<.001) and marginally associated with occult common iliac nodal involvement (odds ratio 2.307, 95% confidence interval 0.978-5.441, P=.056). The percentages of patients with involved lymph node regions entirely encompassed by whole bladder, small pelvic, and extended pelvic CTVs varied with clinical risk factors, ranging from 85.4%, 95.1%, and 100% in non-muscle-invasive patients to 44.7%, 71.1%, and 94.8% in patients with muscle-invasive disease and biopsy LVI. Conclusions: Occult pelvic lymph node rates are substantial for all clinical subgroups, especially patients with LVI on biopsy. Extended

  11. A method to generate fully multi-scale optimal interpolation by combining efficient single process analyses, illustrated by a DINEOF analysis spiced with a local optimal interpolation

    Directory of Open Access Journals (Sweden)

    J.-M. Beckers

    2014-10-01

    Full Text Available We present a method in which the optimal interpolation of multi-scale processes can be expanded into a succession of simpler interpolations. First, we prove how the optimal analysis of a superposition of two processes can be obtained by different mathematical formulations involving iterations and analysis focusing on a single process. From the different mathematical equivalent formulations, we then select the most efficient ones by analyzing the behavior of the different possibilities in a simple and well-controlled test case. The clear guidelines deduced from this experiment are then applied to a real situation in which we combine large-scale analysis of hourly Spinning Enhanced Visible and Infrared Imager (SEVIRI satellite images using data interpolating empirical orthogonal functions (DINEOF with a local optimal interpolation using a Gaussian covariance. It is shown that the optimal combination indeed provides the best reconstruction and can therefore be exploited to extract the maximum amount of useful information from the original data.

  12. Damage to the surface of the small intestinal villus: an objective scale of assessment of the effects of single and fractionated radiation doses

    Energy Technology Data Exchange (ETDEWEB)

    Carr, K.E.; Watt, C. (Glasgow Univ. (UK). Dept. of Anatomy); Hamlet, R.; Nias, A.H.W. (Glasgow Inst. of Radiotherapeutics and Oncology (UK))

    1983-07-01

    Scanning electron microscopy has been used to compare damage to mouse small intestinal mucosa after irradiation with different doses of photons and neutrons. Various stages of the collapse of villous structure seen after radiation include the production of conical and rudimentary villi and a flattened mucosa. A scale is proposed to relate radiation to villous damage. Points from this scale are taken to produce comparative ratios for equivalent damage produced by different radiation conditions. RBE values are quoted for neutron, X and gamma radiation given as single or fractionated irradiation doses and as whole or partial body irradiation. The relationship between the stroma in intravillous pegs and that of the pericryptal compartment is explored.

  13. Damage to the surface of the small intestinal villus: an objective scale of assessment of the effects of single and fractionated radiation doses

    International Nuclear Information System (INIS)

    Carr, K.E.; Watt, C.

    1983-01-01

    Scanning electron microscopy has been used to compare damage to mouse small intestinal mucosa after irradiation with different doses of photons and neutrons. Various stages of the collapse of villous structure seen after radiation include the production of conical and rudimentary villi and a flattened mucosa. A scale is proposed to relate radiation to villous damage. Points from this scale are taken to produce comparative ratios for equivalent damage produced by different radiation conditions. RBE values are quoted for neutron, X and gamma radiation given as single or fractionated irradiation doses and as whole or partial body irradiation. The relationship between the stroma in intravillous pegs and that of the pericryptal compartment is explored. (author)

  14. An efficient routing algorithm for event based monitoring in a plant using virtual sink nodes in a wireless sensor network

    International Nuclear Information System (INIS)

    Jain, Sanjay Kumar; Vietla, Srinivas; Roy, D.A.; Biswas, B.B.; Pithawa, C.K.

    2010-01-01

    A Wireless Sensor Network is a collection of wireless sensor nodes arranged in a self-forming network without aid of any infrastructure or administration. The individual nodes have limited resources and hence efficient communication mechanisms between the nodes have to be devised for continued operation of the network in a plant environment. In wireless sensor networks a sink node or base station at one end acts as the recipient of information gathered by all other sensor nodes in the network and the information arrives at the sink through multiple hops across the nodes of the network. A routing algorithm has been developed in which a virtual sink node is generated whenever hop count of an ordinary node crosses a certain specified value. The virtual sink node acts as a recipient node for data of all neighboring nodes. This virtual sink helps in reducing routing overhead, especially when the sensor network is scaled to a larger network. The advantages with this scheme are less energy consumption, reduced congestion in the network and longevity of the network. The above algorithm is suitable for event based or interval based monitoring systems in nuclear plants. This paper describes the working of the proposed algorithm and provides its implementation details. (author)

  15. Penile Cancer: Contemporary Lymph Node Management.

    Science.gov (United States)

    O'Brien, Jonathan S; Perera, Marlon; Manning, Todd; Bozin, Mike; Cabarkapa, Sonja; Chen, Emily; Lawrentschuk, Nathan

    2017-06-01

    In penile cancer, the optimal diagnostics and management of metastatic lymph nodes are not clear. Advances in minimally invasive staging, including dynamic sentinel lymph node biopsy, have widened the diagnostic repertoire of the urologist. We aimed to provide an objective update of the recent trends in the management of penile squamous cell carcinoma, and inguinal and pelvic lymph node metastases. We systematically reviewed several medical databases, including the Web of Science® (with MEDLINE®), Embase® and Cochrane databases, according to PRISMA (Preferred Reporting Items for Systematic Review and Meta-Analyses) guidelines. The search terms used were penile cancer, lymph node, sentinel node, minimally invasive, surgery and outcomes, alone and in combination. Articles pertaining to the management of lymph nodes in penile cancer were reviewed, including original research, reviews and clinical guidelines published between 1980 and 2016. Accurate and minimally invasive lymph node staging is of the utmost importance in the surgical management of penile squamous cell carcinoma. In patients with clinically node negative disease, a growing body of evidence supports the use of sentinel lymph node biopsies. Dynamic sentinel lymph node biopsy exposes the patient to minimal risk, and results in superior sensitivity and specificity profiles compared to alternate nodal staging techniques. In the presence of locoregional disease, improvements in inguinal or pelvic lymphadenectomy have reduced morbidity and improved oncologic outcomes. A multimodal approach of chemotherapy and surgery has demonstrated a survival benefit for patients with advanced disease. Recent developments in lymph node management have occurred in penile cancer, such as minimally invasive lymph node diagnosis and intervention strategies. These advances have been met with a degree of controversy in the contemporary literature. Current data suggest that dynamic sentinel lymph node biopsy provides excellent

  16. Enhancement characteristics of retroperitoneal lymphomatous lymph nodes

    International Nuclear Information System (INIS)

    Hagtvedt, Trond; Smith, Hans-Joergen; Kolbenstvedt, Alf; Aaloekken, Trond Mogens; Graff, Bjoern Anton; Holte, Harald

    2013-01-01

    Background: Previous studies of CT enhancement of lymphomatous lymph nodes (LLN) of the neck and the mediastinum showed that the LLN had lower enhancement values than normal lymph nodes. Purpose: To elucidate the contrast medium enhancement curves of LLN in the retroperitoneum by comparing the curves of LLN with those of normal lymph nodes, to test whether differences between these curves could be of diagnostic value, and to compare the present enhancement curves of LLN of the retroperitoneum with the curves of LLN of the neck and the mediastinum from previous similar investigations. Material and Methods: Twenty-eight consecutive patients with LLN of the retroperitoneum (three with Hodgkin's lymphoma [HL]) and 21 control patients with sarcomas and thus presumably normal retroperitoneal nodes underwent dynamic CT examinations. The previous, similar investigation of lymph nodes of the neck comprised 28 patients with LLN and the investigation of mediastinal lymph nodes comprised 24 patients with LLN. Results: The enhancement curves of the retroperitoneal LLN had significantly lower attenuation than those of the retroperitoneal control nodes. A combination of peak contrast value and time to peak adjusted to total body weight yielded a diagnostic accuracy which at the best showed a sensitivity of 90.5% with a specificity of 82.6%. The LLN of the retroperitoneum had higher attenuation values than corresponding nodes of the mediastinum but no significant difference was found between LLN of the retroperitoneum and LLN of the neck in previous similar investigations. Conclusion: The comparison of enhancement curves of retroperitoneal LLN with retroperitoneal control nodes showed a marked similarity with and substantiates our previous findings in lymph nodes of the neck and of the mediastinum. The best diagnostic accuracy was achieved by combining the parameters peak contrast value and time to peak and adjusting these values to the body weight. Peak enhancement of the

  17. Initial study of divertor particle and heat flux width scaling in lower-single-null configuration on EAST

    International Nuclear Information System (INIS)

    Wang Liang; Xu Guosheng; Guo Houyang; Gan Kaifu; Gong Xianzu; Hu Liqun

    2013-01-01

    The dependence of divertor particle and power deposition widths on plasma current (I_p) for lower hybrid current driven (LHCD) L- and H-mode plasmas was initially studied in the Experimental Advanced Superconducting Tokamak (EAST) under a lower single null (LSN) divertor configuration. And the profile widths were obtained from the divertor triple Langmuir probe array and an infra-red (IR) camera. It is shown that the deposition widths of divertor particle and heat flux profiles both display a strong negative dependence on increasing plasma current, in L-mode, ELM-free H-mode and ELMy H-mode scenarios. The experimental results show good agreement with the heuristic SOL width model proposed by Goldston. (author)

  18. Scale-dependent effects on wave propagation in magnetically affected single/double-layered compositionally graded nanosize beams

    Science.gov (United States)

    Ebrahimi, Farzad; Barati, Mohammad Reza

    2018-04-01

    This article deals with the wave propagation analysis of single/double layered functionally graded (FG) size-dependent nanobeams in elastic medium and subjected to a longitudinal magnetic field employing nonlocal elasticity theory. Material properties of nanobeam change gradually according to the sigmoid function. Applying an analytical solution, the acoustical and optical dispersion relations are explored for various wave number, nonlocality parameter, material composition, elastic foundation constants, and magnetic field intensity. It is found that frequency and phase velocity of waves propagating in S-FGM nanobeam are significantly affected by these parameters. Also, presence of cut-off and escape frequencies in wave propagation analysis of embedded S-FGM nanobeams is investigated.

  19. Modeling the effects of cohesive energy for single particle on the material removal in chemical mechanical polishing at atomic scale

    International Nuclear Information System (INIS)

    Wang Yongguang; Zhao Yongwu; An Wei; Wang Jun

    2007-01-01

    This paper proposes a novel mathematical model for chemical mechanical polishing (CMP) based on interface solid physical and chemical theory in addition to energy equilibrium knowledge. And the effects of oxidation concentration and particle size on the material removal in CMP are investigated. It is shown that the mechanical energy and removal cohesive energy couple with the particle size, and being a cause of the non-linear size-removal rate relation. Furthermore, it also shows a nonlinear dependence of removal rate on removal cohesive energy. The model predictions are in good qualitative agreement with the published experimental data. The current study provides an important starting point for delineating the micro-removal mechanism in the CMP process at atomic scale

  20. Shortening treatment time in robotic radiosurgery using a novel node reduction technique

    Energy Technology Data Exchange (ETDEWEB)

    Water, Steven van de; Hoogeman, Mischa S.; Breedveld, Sebastiaan; Heijmen, Ben J. M. [Department of Radiation Oncology, Erasmus MC-Daniel den Hoed Cancer Center, Groene Hilledijk 301, 3075 EA Rotterdam (Netherlands)

    2011-03-15

    Purpose: The fraction duration of robotic radiosurgery treatments can be reduced by generating more time-efficient treatment plans with a reduced number of node positions, beams, and monitor units (MUs). Node positions are preprogramed locations where the robot can position the focal spot of the x-ray beam. As the time needed for the robot to travel between node positions takes up a large part of the treatment time, the aim of this study was to develop and evaluate a node reduction technique in order to reduce the treatment time per fraction for robotic radiosurgery. Methods: Node reduction was integrated into the inverse planning algorithm, developed in-house for the robotic radiosurgery modality. It involved repeated inverse optimization, each iteration excluding low-contribution node positions from the planning and resampling new candidate beams from the remaining node positions. Node reduction was performed until the exclusion of a single node position caused a constraint violation, after which the shortest treatment plan was selected retrospectively. Treatment plans were generated with and without node reduction for two lung cases of different complexity, one oropharyngeal case and one prostate case. Plan quality was assessed using the number of node positions, beams and MUs, and the estimated treatment time per fraction. All treatment plans had to fulfill all clinical dose constraints. Extra constraints were added to maintain the low-dose conformality and restrict skin doses during node reduction. Results: Node reduction resulted in 12 residual node positions, on average (reduction by 77%), at the cost of an increase in the number of beams and total MUs of 28% and 9%, respectively. Overall fraction durations (excluding patient setup) were shortened by 25% (range of 18%-40%), on average. Dose distributions changed only little and dose in low-dose regions was effectively restricted by the additional constraints. Conclusions: The fraction duration of robotic

  1. Shortening treatment time in robotic radiosurgery using a novel node reduction technique

    International Nuclear Information System (INIS)

    Water, Steven van de; Hoogeman, Mischa S.; Breedveld, Sebastiaan; Heijmen, Ben J. M.

    2011-01-01

    Purpose: The fraction duration of robotic radiosurgery treatments can be reduced by generating more time-efficient treatment plans with a reduced number of node positions, beams, and monitor units (MUs). Node positions are preprogramed locations where the robot can position the focal spot of the x-ray beam. As the time needed for the robot to travel between node positions takes up a large part of the treatment time, the aim of this study was to develop and evaluate a node reduction technique in order to reduce the treatment time per fraction for robotic radiosurgery. Methods: Node reduction was integrated into the inverse planning algorithm, developed in-house for the robotic radiosurgery modality. It involved repeated inverse optimization, each iteration excluding low-contribution node positions from the planning and resampling new candidate beams from the remaining node positions. Node reduction was performed until the exclusion of a single node position caused a constraint violation, after which the shortest treatment plan was selected retrospectively. Treatment plans were generated with and without node reduction for two lung cases of different complexity, one oropharyngeal case and one prostate case. Plan quality was assessed using the number of node positions, beams and MUs, and the estimated treatment time per fraction. All treatment plans had to fulfill all clinical dose constraints. Extra constraints were added to maintain the low-dose conformality and restrict skin doses during node reduction. Results: Node reduction resulted in 12 residual node positions, on average (reduction by 77%), at the cost of an increase in the number of beams and total MUs of 28% and 9%, respectively. Overall fraction durations (excluding patient setup) were shortened by 25% (range of 18%-40%), on average. Dose distributions changed only little and dose in low-dose regions was effectively restricted by the additional constraints. Conclusions: The fraction duration of robotic

  2. Localized Lymph Node Light Chain Amyloidosis

    Directory of Open Access Journals (Sweden)

    Binod Dhakal

    2015-01-01

    Full Text Available Immunoglobulin-derived light chain amyloidosis can occasionally be associated with localized disease. We present a patient with localized lymph node light chain amyloidosis without an underlying monoclonal protein or lymphoproliferative disorder and review the literature of lymph node amyloidosis discussing work-up and risk factors for systemic progression.

  3. Sentinel lymph node identification with magnetic nanoparticles

    NARCIS (Netherlands)

    Pouw, Joost Jacob

    2016-01-01

    Most solid malignancies have a tendency to spread through the lymphatic system to locoregional lymph nodes. Presence of metastasis is an important prognostic factor, and is used to determine the optimal treatment of the patient. The sentinel lymph nodes (SLNs) receive direct lymphatic drainage from

  4. Testnodes: a Lightweight node-testing infrastructure

    International Nuclear Information System (INIS)

    Fay, R; Bland, J

    2014-01-01

    A key aspect of ensuring optimum cluster reliability and productivity lies in keeping worker nodes in a healthy state. Testnodes is a lightweight node testing solution developed at Liverpool. While Nagios has been used locally for general monitoring of hosts and services, Testnodes is optimised to answer one question: is there any reason this node should not be accepting jobs? This tight focus enables Testnodes to inspect nodes frequently with minimal impact and provide a comprehensive and easily extended check with each inspection. On the server side, Testnodes, implemented in python, interoperates with the Torque batch server to control the nodes production status. Testnodes remotely and in parallel executes client-side test scripts and processes the return codes and output, adjusting the node's online/offline status accordingly to preserve the integrity of the overall batch system. Testnodes reports via log, email and Nagios, allowing a quick overview of node status to be reviewed and specific node issues to be identified and resolved quickly. This presentation will cover testnodes design and implementation, together with the results of its use in production at Liverpool, and future development plans.

  5. Contrast enhanced ultrasound of sentinel lymph nodes

    Directory of Open Access Journals (Sweden)

    XinWu Cui

    2013-03-01

    Full Text Available Sentinel lymph nodes are the first lymph nodes in the region that receive lymphatic drainage from a primary tumor. The detection or exclusion of sentinel lymph node micrometastases is critical in the staging of cancer, especially breast cancer and melanoma because it directly affects patient’s prognosis and surgical management. Currently, intraoperative sentinel lymph node biopsies using blue dye and radioisotopes are the method of choice for the detection of sentinel lymph node with high identification rate. In contrast, conventional ultrasound is not capable of detecting sentinel lymph nodes in most cases. Contrast enhanced ultrasound with contrast specific imaging modes has been used for the evaluation and diagnostic work-up of peripherally located suspected lymphadenopathy. The method allows for real-time analysis of all vascular phases and the visualization of intranodal focal “avascular” areas that represent necrosis or deposits of neoplastic cells. In recent years, a number of animal and human studies showed that contrast enhanced ultrasound can be also used for the detection of sentinel lymph node, and may become a potential application in clinical routine. Several contrast agents have been used in those studies, including albumin solution, hydroxyethylated starch, SonoVue®, Sonazoid® and Definity®. This review summarizes the current knowledge about the use of ultrasound techniques in detection and evaluation of sentinel lymph node.

  6. A road map for the realization of global-scale thorium breeding fuel cycle by single molten-fluoride flow

    International Nuclear Information System (INIS)

    Furukawa, K.; Arakawa, K.; Erbay, L. B.

    2007-01-01

    For global survival in this century, we urgently need to launch a completely new global nuclear fission industry. To get worldwide public acceptance of nuclear energy, improvements are essential not only on safety, radio-waste management and economy but also especially nuclear proliferation resistance and safeguards. However, such global fission industry cannot replace the present fossil fuel industry in the next 50 years, unless the doubling-time of nuclear energy is less than 10 years, preferably 5-7 years. Such a doubling-time cannot be established by any kind of classical 'Fission Breeding Power Station' concept. We need a symbiotic system which couples fission power reactors with a system which can convert fertile thorium to fissile U-233, such as a spallation or D/T fusion (if and when it becomes available). For such a purpose, THORIMS-NES [Thorium Molten-Salt Nuclear Energy Synergetic System] has been proposed, which is composed of simple thermal fission power stations (FUJI) and fissile producing Accelerator Molten-Salt Breeder (AMSB). Its system functions are very ambitious, delicate and complex, but can be realized in the form of simple hardware applying the multifunctional 'single-phase molten-fluoride' circulation system. This system has no difficulties relating with 'radiation-damage', 'heat-removal' and 'chemical processing' owing to the simple 'idealistic ionic liquid' character. FUJI is size-flexible (economical even in smaller sizes), fuel self-sustaining without any continuous chemical processing and without core-graphite replacement, and AMSB is based on a single-fluid molten-salt target/blanket concept, which solves most engineering difficulties such as radiation-damage, heat-removal etc., except high-current proton accelerator development. Several AMSBs are accommodated in the regional centers (several ten sites in the world) with batch chemical processing plants including radio-waste management. The integrated thorium breeding fuel cycle is

  7. Preoperative 18F-FDG-PET/CT imaging and sentinel node biopsy in the detection of regional lymph node metastases in malignant melanoma.

    Science.gov (United States)

    Singh, Baljinder; Ezziddin, Samer; Palmedo, Holger; Reinhardt, Michael; Strunk, Holger; Tüting, Thomas; Biersack, Hans-Jürgen; Ahmadzadehfar, Hojjat

    2008-10-01

    The objective of this study was to evaluate the role of preoperative 18F-fluorodeoxyglucose-positron emission tomography/computed tomography scanning, preoperative lymphoscintigraphy (LS), and sentinel lymph node biopsy in patients with malignant melanoma. Fifty-two patients (36 men: 16 women; mean age 55.0+/-13.0 years; median age 61 years; range 17-76 years) with malignant melanoma were selected. According to the latest version of the American Joint Committee on Cancer staging system, the disease in the study patients was initially classified as either stage I or II. The other primary tumor characteristics were mean Breslow depth=2.87 mm and median=2 mm; range 1-12.0 mm and Clarks levels III-V. None of the study patients had clinical or radiological evidence of regional lymph node metastatic disease. At least one sentinel node was identified in all patients. Preoperative LS detected a total of 111 sentinel lymph nodes (average 2.13 sentinel lymph node per patient) and demonstrated a single nodal draining basin in 38 (73%) patients and multiple (2-3 draining basins) in the remaining 14 (27%) patients. Fourteen out of the 52 patients (27%) had at least one involved sentinel node. Positron emission tomography was true positive in two patients with a sentinel node greater than 1 cm and false positive in two other patients. In this study, the detection of sentinel lymph node by LS and gamma probe had a sensitivity of 100%. In contrast, 18F-FDG-PET imaging demonstrated very low sensitivity (14.3%; 95% CI, 2.5 to 44%) and positive predictive value (50%; 95% CI, 9 to 90%) for localizing the subclinical nodal metastases. The specificity, net present value, and diagnostic accuracy were 94.7, 75, and 73%, respectively. Preoperative fluorodeoxyglucose-positron emission tomography/computed tomography imaging is not able to substitute LS/sentinel lymph node biopsy in patients at stage I or II.

  8. LYMPHOCYTIC THYROIDITIS IS ASSOCIATED WITH INCREASED NUMBER OF BENIGN CERVICAL NODES AND FEWER CENTRAL NECK COMPARTMENT METASTATIC LYMPH NODES IN PATIENTS WITH DIFFERENTIATED THYROID CANCER.

    Science.gov (United States)

    Donangelo, Ines; Walts, Ann E; Bresee, Catherine; Braunstein, Glenn D

    2016-10-01

    Whether or not autoimmune thyroid disease influences the progression of differentiated thyroid cancer (DTC) remains controversial. Findings of previous studies are influenced by lead time bias and/or procedure bias selection. These biases can be reduced by studying a single-institution patient population that underwent a similar extent of surgical resection. From a cohort of 660 patients with DTC who underwent thyroidectomy, we retrospectively studied 357 patients who underwent total thyroidectomy and central compartment node dissection (CCND) for DTC between 2003 and 2013. Forty-one percent (140/345) of study patients had lymphocytic thyroiditis (LT), and 30% (91/301) had serum positive for thyroglobulin antibody (TgAb). LT was reported in 78% of the TgAb-positive cases. Sixty percent (213/357) of cases had metastatic thyroid carcinoma in 1 or more neck lymph nodes (55% [198/357] central compartment, and 22% [77/356] lateral compartment). Patients with LT had fewer metastatic cervical lymph nodes than those with no LT (2.7 ± 4.7 vs 3.5 ± 4.8, respectively, P = .0285). Patients with positive TgAb and thyroiditis had a larger number of benign cervical lymph nodes removed than those with negative TgAb or no LT. No significant difference was observed in age, tumor size, multifocality, extrathyroidal extension, vascular invasion, or frequency of cervical lymph node metastasis between TgAb-negative and -positive cases or between cases with and without LT. Lymphocytic thyroiditis is associated with fewer central neck compartment metastatic lymph nodes and a larger number of excised reactive benign cervical lymph nodes. Whether this association indicates a protective role of thyroid autoimmunity in lymph node spreading remains unclear. CCND = central compartment node dissection DTC = differentiated thyroid cancer HT = Hashimoto thyroiditis LT = lymphocytic thyroiditis TgAb = thyroglobulin antibody TPO = thyroid peroxidase.

  9. The validity of the Satisfaction with Life Scale in adolescents and a comparison with single-item life satisfaction measures: a preliminary study.

    Science.gov (United States)

    Jovanović, Veljko

    2016-12-01

    The validity of the life satisfaction measures commonly used among adults has been rarely examined in adolescent samples. The present research had two main goals: (1) to evaluate the structural validity of the Satisfaction with Life Scale (SWLS) among adolescents and to test measurement invariance across gender; (2) to compare the criterion and convergent validity of the SWLS and single-item life satisfaction measures among adolescents. Three samples of Serbian adolescents were recruited for the present research. Study 1 (N = 481, M age  = 17.01 years) examined the structure of the SWLS via confirmatory factor analysis (CFA) and evaluated measurement invariance of the SWLS across gender by a multi-group CFA. Study 2 (N = 283, M age  = 17.34 years) and Study 3 (N = 220, M age  = 16.73 years) compared the convergent validity of the SWLS and single-item life satisfaction measures. The results of Study 1 supported the original one-factor model of the SWLS among adolescents and provided evidence for strong measurement invariance of the SWLS across gender. The findings of Study 2 and Study 3 showed that the SWLS and single-item measures were equally valid and strongly associated (r = .734 in Study 2 and r = .668 in Study 3). No substantial differences in correlations with school success and well-being indicators were found between the SWLS and single-item measures. Our findings support the use of the SWLS among adolescents and indicate that single-item life satisfaction measures perform as well as the SWLS in adolescent samples.

  10. Sentinel lymph node imaging in breast cancer

    International Nuclear Information System (INIS)

    Kim, Byung Tae

    1999-01-01

    Currently, dissection of the axillary or regional lymph nodes is considered the standard staging procedure in breast cancer. However, accumulating evidence is becoming available that the sentinel node concept may provide the same or even better staging information. In the case of melanoma, it is proven that the histological characteristics of the sentinel node reflect the histological characteristics of the distal part of the lymphatic basin. Morbidity can be reduced significantly by the use of sentinel node dissection as several authors have reported successful introduction of this technique into clinical practice. But in breast cancer patients, there are significant differences in practice relating to the technology, such as radiopharmaceuticals, injection sites, volume of injectate, combination with vital blue dye, preoperative lymphoscintigraphy, etc. Valuable reports on these topics appeared in recent journals. This review is a summary of those reports for nuclear physicians interested in sentinel node detection by lymphoscintigraphy in breast cancer patients

  11. Critical Issues in Modelling Lymph Node Physiology

    Directory of Open Access Journals (Sweden)

    Dmitry Grebennikov

    2016-12-01

    Full Text Available In this study, we discuss critical issues in modelling the structure and function of lymph nodes (LNs, with emphasis on how LN physiology is related to its multi-scale structural organization. In addition to macroscopic domains such as B-cell follicles and the T cell zone, there are vascular networks which play a key role in the delivery of information to the inner parts of the LN, i.e., the conduit and blood microvascular networks. We propose object-oriented computational algorithms to model the 3D geometry of the fibroblastic reticular cell (FRC network and the microvasculature. Assuming that a conduit cylinder is densely packed with collagen fibers, the computational flow study predicted that the diffusion should be a dominating process in mass transport than convective flow. The geometry models are used to analyze the lymph flow properties through the conduit network in unperturbed- and damaged states of the LN. The analysis predicts that elimination of up to 60%–90% of edges is required to stop the lymph flux. This result suggests a high degree of functional robustness of the network.

  12. Temporal node centrality in complex networks

    Science.gov (United States)

    Kim, Hyoungshick; Anderson, Ross

    2012-02-01

    Many networks are dynamic in that their topology changes rapidly—on the same time scale as the communications of interest between network nodes. Examples are the human contact networks involved in the transmission of disease, ad hoc radio networks between moving vehicles, and the transactions between principals in a market. While we have good models of static networks, so far these have been lacking for the dynamic case. In this paper we present a simple but powerful model, the time-ordered graph, which reduces a dynamic network to a static network with directed flows. This enables us to extend network properties such as vertex degree, closeness, and betweenness centrality metrics in a very natural way to the dynamic case. We then demonstrate how our model applies to a number of interesting edge cases, such as where the network connectivity depends on a small number of highly mobile vertices or edges, and show that our centrality definition allows us to track the evolution of connectivity. Finally we apply our model and techniques to two real-world dynamic graphs of human contact networks and then discuss the implication of temporal centrality metrics in the real world.

  13. Efficient mutagenesis by Cas9 protein-mediated oligonucleotide insertion and large-scale assessment of single-guide RNAs.

    Science.gov (United States)

    Gagnon, James A; Valen, Eivind; Thyme, Summer B; Huang, Peng; Akhmetova, Laila; Ahkmetova, Laila; Pauli, Andrea; Montague, Tessa G; Zimmerman, Steven; Richter, Constance; Schier, Alexander F

    2014-01-01

    The CRISPR/Cas9 system has been implemented in a variety of model organisms to mediate site-directed mutagenesis. A wide range of mutation rates has been reported, but at a limited number of genomic target sites. To uncover the rules that govern effective Cas9-mediated mutagenesis in zebrafish, we targeted over a hundred genomic loci for mutagenesis using a streamlined and cloning-free method. We generated mutations in 85% of target genes with mutation rates varying across several orders of magnitude, and identified sequence composition rules that influence mutagenesis. We increased rates of mutagenesis by implementing several novel approaches. The activities of poor or unsuccessful single-guide RNAs (sgRNAs) initiating with a 5' adenine were improved by rescuing 5' end homogeneity of the sgRNA. In some cases, direct injection of Cas9 protein/sgRNA complex further increased mutagenic activity. We also observed that low diversity of mutant alleles led to repeated failure to obtain frame-shift mutations. This limitation was overcome by knock-in of a stop codon cassette that ensured coding frame truncation. Our improved methods and detailed protocols make Cas9-mediated mutagenesis an attractive approach for labs of all sizes.

  14. Small scale endemism in Brazil's Atlantic Forest: 14 new species of Mesabolivar (Araneae, Pholcidae), each known from a single locality.

    Science.gov (United States)

    Huber, Bernhard A

    2015-04-07

    In an ongoing mega-transect project that aims at analyzing pholcid spider diversity and distribution in the Atlantic Forest of Brazil, many species appear restricted to small geographic ranges. Of the 84 species collected between 2003 and 2011 at 17 sites between Bahia and Santa Catarina, 51 species (61%) were found at only one locality. The present paper focuses on such species in the genus Mesabolivar, and compares diversity and distribution patterns of this genus within and outside the Atlantic Forest. The percentage of species known from single localities is higher in the Atlantic Forest (34 of 52 species; 65%) than outside the Atlantic Forest (10 of 25; 40%). Distribution rages of species in the Atlantic Forest are significantly smaller than of species outside the Atlantic Forest (mean maximum distances between localities: 184 versus 541 km; medians: 10 km versus 220 km). The following species are newly described (arranged from north to south), each currently known from the respective type locality only: M. caipora; M. kathrinae; M. bonita; M. pau (Bahia); M. monteverde; M. perezi (Espírito Santo); M. giupponii; M. goitaca; M. sai (Rio de Janeiro); M. tamoio; M. unicornis; M. gabettae; M. inornatus (São Paulo); M. itapoa (Santa Catarina).

  15. Advanced CMOS device technologies for 45 nm node and below

    Directory of Open Access Journals (Sweden)

    A. Veloso, T. Hoffmann, A. Lauwers, H. Yu, S. Severi, E. Augendre, S. Kubicek, P. Verheyen, N. Collaert, P. Absil, M. Jurczak and S. Biesemans

    2007-01-01

    Full Text Available We review and discuss the latest developments and technology options for 45 nm node and below, with scaled planar bulk MOSFETs and MuGFETs as emerging devices. One of the main metal gate (MG candidates for scaled CMOS technologies are fully silicided (FUSI gates. In this work, by means of a selective and controlled poly etch-back integration process, dual work-function Ni-based FUSI/HfSiON CMOS circuits with record ring oscillator performance (high-VT are reported (17 ps at VDD=1.1 V and 20 pA/μm Ioff, meeting the ITRS 45 nm node requirement for low-power (LP CMOS. Compatibility of FUSI and other MG with known stress boosters like stressed CESL (contact-etch-stop-layer with high intrinsic stress or embedded SiGe in the pMOS S/D regions is validated. To obtain MuGFET devices that are competitive, as compared to conventional planar bulk devices, and that meet the stringent drive and leakage current requirements for the 32 nm node and beyond, higher channel mobilities are required. Results obtained by several strain engineering methods are presented here.

  16. Detecting cm-scale hot spot over 24-km-long single-mode fiber by using differential pulse pair BOTDA based on double-peak spectrum.

    Science.gov (United States)

    Diakaridia, Sanogo; Pan, Yue; Xu, Pengbai; Zhou, Dengwang; Wang, Benzhang; Teng, Lei; Lu, Zhiwei; Ba, Dexin; Dong, Yongkang

    2017-07-24

    In distributed Brillouin optical fiber sensor when the length of the perturbation to be detected is much smaller than the spatial resolution that is defined by the pulse width, the measured Brillouin gain spectrum (BGS) experiences two or multiple peaks. In this work, we propose and demonstrate a technique using differential pulse pair Brillouin optical time-domain analysis (DPP-BOTDA) based on double-peak BGS to enhance small-scale events detection capability, where two types of single mode fiber (main fiber and secondary fiber) with 116 MHz Brillouin frequency shift (BFS) difference have been used. We have realized detection of a 5-cm hot spot at the far end of 24-km single mode fiber by employing a 50-cm spatial resolution DPP-BOTDA with only 1GS/s sampling rate (corresponding to 10 cm/point). The BFS at the far end of 24-km sensing fiber has been measured with 0.54 MHz standard deviation which corresponds to a 0.5°C temperature accuracy. This technique is simple and cost effective because it is implemented using the similar experimental setup of the standard BOTDA, however, it should be noted that the consecutive small-scale events have to be separated by a minimum length corresponding to the spatial resolution defined by the pulse width difference.

  17. Controllability of Weighted and Directed Networks with Nonidentical Node Dynamics

    Directory of Open Access Journals (Sweden)

    Linying Xiang

    2013-01-01

    Full Text Available The concept of controllability from control theory is applied to weighted and directed networks with heterogenous linear or linearized node dynamics subject to exogenous inputs, where the nodes are grouped into leaders and followers. Under this framework, the controllability of the controlled network can be decomposed into two independent problems: the controllability of the isolated leader subsystem and the controllability of the extended follower subsystem. Some necessary and/or sufficient conditions for the controllability of the leader-follower network are derived based on matrix theory and graph theory. In particular, it is shown that a single-leader network is controllable if it is a directed path or cycle, but it is uncontrollable for a complete digraph or a star digraph in general. Furthermore, some approaches to improving the controllability of a heterogenous network are presented. Some simulation examples are given for illustration and verification.

  18. Horizontally scaling dCache SRM with the Terracotta platform

    International Nuclear Information System (INIS)

    Perelmutov, T; Crawford, M; Moibenko, A; Oleynik, G

    2011-01-01

    The dCache disk caching file system has been chosen by a majority of LHC experiments' Tier 1 centers for their data storage needs. It is also deployed at many Tier 2 centers. The Storage Resource Manager (SRM) is a standardized grid storage interface and a single point of remote entry into dCache, and hence is a critical component. SRM must scale to increasing transaction rates and remain resilient against changing usage patterns. The initial implementation of the SRM service in dCache suffered from an inability to support clustered deployment, and its performance was limited by the hardware of a single node. Using the Terracotta platform[l], we added the ability to horizontally scale the dCache SRM service to run on multiple nodes in a cluster configuration, coupled with network load balancing. This gives site administrators the ability to increase the performance and reliability of SRM service to face the ever-increasing requirements of LHC data handling. In this paper we will describe the previous limitations of the architecture SRM server and how the Terracotta platform allowed us to readily convert single node service into a highly scalable clustered application.

  19. Horizontally scaling dChache SRM with the Terracotta platform

    International Nuclear Information System (INIS)

    Perelmutov, T.; Crawford, M.; Moibenko, A.; Oleynik, G.

    2011-01-01

    The dCache disk caching file system has been chosen by a majority of LHC experiments Tier 1 centers for their data storage needs. It is also deployed at many Tier 2 centers. The Storage Resource Manager (SRM) is a standardized grid storage interface and a single point of remote entry into dCache, and hence is a critical component. SRM must scale to increasing transaction rates and remain resilient against changing usage patterns. The initial implementation of the SRM service in dCache suffered from an inability to support clustered deployment, and its performance was limited by the hardware of a single node. Using the Terracotta platform, we added the ability to horizontally scale the dCache SRM service to run on multiple nodes in a cluster configuration, coupled with network load balancing. This gives site administrators the ability to increase the performance and reliability of SRM service to face the ever-increasing requirements of LHC data handling. In this paper we will describe the previous limitations of the architecture SRM server and how the Terracotta platform allowed us to readily convert single node service into a highly scalable clustered application.

  20. Beyond single syllables: large-scale modeling of reading aloud with the Connectionist Dual Process (CDP++) model.

    Science.gov (United States)

    Perry, Conrad; Ziegler, Johannes C; Zorzi, Marco

    2010-09-01

    Most words in English have more than one syllable, yet the most influential computational models of reading aloud are restricted to processing monosyllabic words. Here, we present CDP++, a new version of the Connectionist Dual Process model (Perry, Ziegler, & Zorzi, 2007). CDP++ is able to simulate the reading aloud of mono- and disyllabic words and nonwords, and learns to assign stress in exactly the same way as it learns to associate graphemes with phonemes. CDP++ is able to simulate the monosyllabic benchmark effects its predecessor could, and therefore shows full backwards compatibility. CDP++ also accounts for a number of novel effects specific to disyllabic words, including the effects of stress regularity and syllable number. In terms of database performance, CDP++ accounts for over 49% of the reaction time variance on items selected from the English Lexicon Project, a very large database of several thousand of words. With its lexicon of over 32,000 words, CDP++ is therefore a notable example of the successful scaling-up of a connectionist model to a size that more realistically approximates the human lexical system. Copyright © 2010 Elsevier Inc. All rights reserved.

  1. Sentinel lymph node biopsy: clinical relevance

    International Nuclear Information System (INIS)

    Howman-Giles, R.

    2002-01-01

    Sentinel lymph node biopsy (SLNB) has become an important technique in the management of patients with intermediate level melanoma, clinical operable breast cancer and some other cancers. The technique relies on lymphatic mapping to define the lymph drainage from a primary tumour with the premise that the lymph nodes, which directly drain from that area, will reflect the tumour status of the remainder of the node field. Current techniques use lymphoscintigraphy where a radioactive labelled particle and / or blue dye are injected intradermally or intraparenchymally to map the lymph drainage, often in conjunction with a radioactive gamma probe at surgery. In patients with melanoma the SLNB has improved the staging and prognostic information by more accurate determination of whether regional lymph nodes have metastatic spread. This has a major impact on patient management as those patients with negative nodes do not require regional lymph node dissection and have a significantly better prognosis. In our experience of over 3000 patients the combined sentinel node biopsy technique localised accurately 98% of sentinel lymph nodes. Lymphoscintigraphy in patients with melanoma to locate the sentinel lymph nodes involves the intradermal injection of a radiocolloid around the melanoma site or the excision biopsy site. Injections of 5 -10 MBq in 0.05-0.1ml/inj are used and typically 4 injections are usually required. Following tracer injection dynamic imaging is performed to follow the lymphatic collecting vessels until they reach the draining sentinel nodes. An image should be acquired as the vessels reach the node field so that the sentinel nodes directly receiving the channels can be identified and distinguished from any second tier nodes which may sometimes be seen. Delayed scans are performed 2 hours later at which time all regions which can possible drain the primary melanoma site are examined with 5-10 minute static images. The surface location of all sentinel nodes is

  2. The 'Sentinel Node' Concept: More Questions Raised than Answers Provided?

    Science.gov (United States)

    Schlag

    1998-01-01

    -guided detection of the sentinel node. At present, a multitude of studies are conducted in a variety of tumors and sites, aiming at further refinements of the technique or at clinical evaluation in comparison with established lympadenectomy. The results may well change many aspects of our operative strategy in the near future. However, assuming a technically optimized procedure, will this solve the underlying tumor biological and clinical problem with respect to the necessity and efficacy of a regional lymph node dissection in node-positive cases? This is not the case; moreover, there are additional questions raised and left unanswered so far. Without any doubt, the rate of unnecessary diagnostic lymph node dissections can be considerably reduced as soon as the sentinel node concept is sufficiently validated for general use outside clinical trials. This would be a clear step forward. It is undetermined, however, how far a cancer patient with a positive sentinel node-thus already proven lymphatic metastases-would still profit from a more or less extensive lymph node dissection. It might be sufficient to use the staging information obtained through the sentinel node's status alone to decide upon adjuvant therapies. A further aspect arises from the possibility for investigating this single and supposedly most representative lymph node in far more detail than it would be possible for the large number of nodes previously sampled in conventional lymphatic dissections. This more extensive work-up may include serial sectioning, immunological and molecular techniques to enhance the sensitivity for micrometastases detection. However, very little is known about the true prognostic significance of such conventionally occult micrometastases, and even less experience exists as to the value of adjuvant therapies in those cases. Thus, while the sentinel node procedure will probably enable a more precise though less invasive lymphatic staging of malignant disease, it raises a number of important

  3. Ranking stability and super-stable nodes in complex networks.

    Science.gov (United States)

    Ghoshal, Gourab; Barabási, Albert-László

    2011-07-19

    Pagerank, a network-based diffusion algorithm, has emerged as the leading method to rank web content, ecological species and even scientists. Despite its wide use, it remains unknown how the structure of the network on which it operates affects its performance. Here we show that for random networks the ranking provided by pagerank is sensitive to perturbations in the network topology, making it unreliable for incomplete or noisy systems. In contrast, in scale-free networks we predict analytically the emergence of super-stable nodes whose ranking is exceptionally stable to perturbations. We calculate the dependence of the number of super-stable nodes on network characteristics and demonstrate their presence in real networks, in agreement with the analytical predictions. These results not only deepen our understanding of the interplay between network topology and dynamical processes but also have implications in all areas where ranking has a role, from science to marketing.

  4. Noninvasive diagnosis of axillary node metastases with monoclonal antibody lymphoscintigraphy

    International Nuclear Information System (INIS)

    Fig, L.M.; Von Moll, L.; Brown, R.; Harness, J.; Appleman, H.; Stevens, R.; Johnson, J.W.; Mudgett, E.; Colcher, D.; Schlom, J.; Lichter, A.; Wicha, M.; Wahl, R.L.

    1989-01-01

    This study was undertaken to determine whether 131-I labeled B72.3 monoclonal antibody, when injected subcutaneously in patients with known breast cancer, successfully detects lymph node metastases. Eleven women with biopsy-proven B72.3 antibody-reactive breast cancer (determined by immunoperoxidase staining) received subcutaneous injections of 500 μ Ci 131-I B72.3 in ipsilateral finger web spaces (or, in three cases, intralesional injections into the site of the breast tumor). The antibody is a IgGlk reactive with a high molecular weight antigen found on most breast carcinomas. Images of the axilla were obtained immediately after injection and serially to 72 hours. Nodal uptake was scored on a 0-3+ scale in a blinded fashion and correlated with pathologic findings from lymph node dissection

  5. High-accuracy single-pass InSAR DEM for large-scale flood hazard applications

    Science.gov (United States)

    Schumann, G.; Faherty, D.; Moller, D.

    2017-12-01

    In this study, we used a unique opportunity of the GLISTIN-A (NASA airborne mission designed to characterizing the cryosphere) track to Greenland to acquire a high-resolution InSAR DEM of a large area in the Red River of the North Basin (north of Grand Forks, ND, USA), which is a very flood-vulnerable valley, particularly in spring time due to increased soil moisture content near state of saturation and/or, typical for this region, snowmelt. Having an InSAR DEM that meets flood inundation modeling and mapping requirements comparable to LiDAR, would demonstrate great application potential of new radar technology for national agencies with an operational flood forecasting mandate and also local state governments active in flood event prediction, disaster response and mitigation. Specifically, we derived a bare-earth DEM in SAR geometry by first removing the inherent far range bias related to airborne operation, which at the more typical large-scale DEM resolution of 30 m has a sensor accuracy of plus or minus 2.5 cm. Subsequently, an intelligent classifier based on informed relationships between InSAR height, intensity and correlation was used to distinguish between bare-earth, roads or embankments, buildings and tall vegetation in order to facilitate the creation of a bare-earth DEM that would meet the requirements for accurate floodplain inundation mapping. Using state-of-the-art LiDAR terrain data, we demonstrate that capability by achieving a root mean squared error of approximately 25 cm and further illustrating its applicability to flood modeling.

  6. Isolated perifacial lymph node metastasis in oral squamous cell carcinoma with clinically node-negative neck.

    Science.gov (United States)

    Agarwal, Sangeet Kumar; Arora, Sowrabh Kumar; Kumar, Gopal; Sarin, Deepak

    2016-10-01

    The incidence of occult perifacial nodal disease in oral cavity squamous cell carcinoma is not well reported. The purpose of this study was to evaluate the incidence of isolated perifacial lymph node metastasis in patients with oral squamous cell carcinoma with a clinically node-negative neck. The study will shed light on current controversies and will provide valuable clinical and pathological information in the practice of routine comprehensive removal of these lymph node pads in selective neck dissection in the node-negative neck. Prospective analysis. This study was started in August 2011 when intraoperatively we routinely separated the lymph node levels from the main specimen for evaluation of the metastatic rate to different lymph node levels in 231 patients of oral squamous cell cancer with a clinically node-negative neck. The current study demonstrated that 19 (8.22%) out of 231 patients showed ipsilateral isolated perifacial lymph node involvement. The incidence of isolated perifacial nodes did not differ significantly between the oral tongue (7.14%) and buccal mucosa (7.75%). Incidence was statistically significant in cases with lower age group (oral squamous cell carcinoma with a clinically node-negative neck. The incidence of isolated perifacial involvement is high in cases of buccal mucosal and tongue cancers. A meticulous dissection of the perifacial nodes seems prudent when treating the neck in oral cavity squamous cell carcinoma. 4 Laryngoscope, 126:2252-2256, 2016. © 2016 The American Laryngological, Rhinological and Otological Society, Inc.

  7. Large-scale image-based profiling of single-cell phenotypes in arrayed CRISPR-Cas9 gene perturbation screens.

    Science.gov (United States)

    de Groot, Reinoud; Lüthi, Joel; Lindsay, Helen; Holtackers, René; Pelkmans, Lucas

    2018-01-23

    High-content imaging using automated microscopy and computer vision allows multivariate profiling of single-cell phenotypes. Here, we present methods for the application of the CISPR-Cas9 system in large-scale, image-based, gene perturbation experiments. We show that CRISPR-Cas9-mediated gene perturbation can be achieved in human tissue culture cells in a timeframe that is compatible with image-based phenotyping. We developed a pipeline to construct a large-scale arrayed library of 2,281 sequence-verified CRISPR-Cas9 targeting plasmids and profiled this library for genes affecting cellular morphology and the subcellular localization of components of the nuclear pore complex (NPC). We conceived a machine-learning method that harnesses genetic heterogeneity to score gene perturbations and identify phenotypically perturbed cells for in-depth characterization of gene perturbation effects. This approach enables genome-scale image-based multivariate gene perturbation profiling using CRISPR-Cas9. © 2018 The Authors. Published under the terms of the CC BY 4.0 license.

  8. [The related factors of head and neck mocosal melanoma with lymph node metastasis].

    Science.gov (United States)

    Yin, G F; Guo, W; Chen, X H; Huang, Z G

    2017-12-05

    Objective: To investigate the related factors of mucosal melanoma of head and neck with lymph node metastasis for early diagnosis and further treatments. Method: A retrospective analysis of 117 cases of head and neck mucosal malignant melanoma patients which received surgical treatment was performed. Eleven cases of patients with pathologically confirmed lymph node metastasis and 33 cases without lymph node metastasis (1∶3) were randomly selected to analyze. The related factors of lymph node metastasis of head and neck mucosal melanoma patients including age, gender, whether the existence of recurrence, bone invasion, lesion location were analyzed. The single factor and logistic regression analysis were performed, P difference was statistically significant. Result: The lymph node metastasis rate of head and neck mucosal melanoma was 9.40%(11/117), the single factor analysis showed that there were 3 factors to be associated with lymph node metastasis, which was recurrence ( P =0.0000), bone invasion ( P =0.001), primary position ( P =0.007). Recurrence ( P =0.021) was a risk factor for lymph node metastasis according to the Logistic regression analysis, and the impact of bone invasion ( P =0.487) and primary location ( P =0.367) remained to be further explored. Conclusion: The patients of head and neck mucosal melanoma with the presence of recurrent usually accompanied by a further progression of the disease, such as lymph node metastasis, so for recurrent patients should pay special attention to the situation of lymph node and choose the reasonable treatment. Copyright© by the Editorial Department of Journal of Clinical Otorhinolaryngology Head and Neck Surgery.

  9. An Ensemble Three-Dimensional Constrained Variational Analysis Method to Derive Large-Scale Forcing Data for Single-Column Models

    Science.gov (United States)

    Tang, Shuaiqi

    Atmospheric vertical velocities and advective tendencies are essential as large-scale forcing data to drive single-column models (SCM), cloud-resolving models (CRM) and large-eddy simulations (LES). They cannot be directly measured or easily calculated with great accuracy from field measurements. In the Atmospheric Radiation Measurement (ARM) program, a constrained variational algorithm (1DCVA) has been used to derive large-scale forcing data over a sounding network domain with the aid of flux measurements at the surface and top of the atmosphere (TOA). We extend the 1DCVA algorithm into three dimensions (3DCVA) along with other improvements to calculate gridded large-scale forcing data. We also introduce an ensemble framework using different background data, error covariance matrices and constraint variables to quantify the uncertainties of the large-scale forcing data. The results of sensitivity study show that the derived forcing data and SCM simulated clouds are more sensitive to the background data than to the error covariance matrices and constraint variables, while horizontal moisture advection has relatively large sensitivities to the precipitation, the dominate constraint variable. Using a mid-latitude cyclone case study in March 3rd, 2000 at the ARM Southern Great Plains (SGP) site, we investigate the spatial distribution of diabatic heating sources (Q1) and moisture sinks (Q2), and show that they are consistent with the satellite clouds and intuitive structure of the mid-latitude cyclone. We also evaluate the Q1 and Q2 in analysis/reanalysis, finding that the regional analysis/reanalysis all tend to underestimate the sub-grid scale upward transport of moist static energy in the lower troposphere. With the uncertainties from large-scale forcing data and observation specified, we compare SCM results and observations and find that models have large biases on cloud properties which could not be fully explained by the uncertainty from the large-scale forcing

  10. Practice variation in defining sentinel lymph nodes on lymphoscintigrams in oral cancer patients

    Energy Technology Data Exchange (ETDEWEB)

    Flach, Geke B.; Bree, Remco de [VU University Medical Center, Department of Otolaryngology-Head and Neck Surgery, De Boelelaan 1117, 1081 HV Amsterdam, PO Box 7057, Amsterdam (Netherlands); Schie, Annelies van; Hoekstra, Otto S. [VU University Medical Center, Department of Radiology and Nuclear Medicine, Amsterdam (Netherlands); Witte, Birgit I. [VU University Medical Center, Department of Epidemiology and Biostatistics, Amsterdam (Netherlands); Olmos, Renato A.V. [VU University Medical Center, Department of Nuclear Medicine, Amsterdam (Netherlands); Klop, W.M.C. [Netherlands Cancer Institute/Antoni van Leeuwenhoek Hospital, Department of Head and Neck Surgery and Oncology, Amsterdam (Netherlands)

    2014-12-15

    Lymphoscintigraphic imaging and adequate interpretation of the lymphatic drainage pattern is an essential step in the sentinel lymph node biopsy (SLNB) procedure. In oral cancer, identification of the sentinel lymph node (SLN) can be challenging. In this study, interobserver variability in defining SLNs on lymphoscintigrams was evaluated in patients with T1-T2 stage N0 oral cancer. Sixteen observers (head and neck surgeons, nuclear medicine physicians or teams of both) from various institutes were asked which criteria they use to consider a hot focus on the lymphoscintigram as SLN. Lymphoscintigrams of 9 patients with 47 hot foci (3-9 per patient) were assessed, using a scale of 'yes/equivocal/no'. Bilateral drainage was seen in four of nine cases. In three cases additional late single photon emission computed tomography (SPECT)/CT scanning was performed. Interobserver variability was evaluated by kappa (κ) analysis, using linear weighted pairwise comparison of the observers. Conservative (equivocal analysed as no) and sensitive (equivocal analysed as yes) assessment strategies were investigated using pairwise kappa analysis. Various definitions of SLN on lymphoscintigrams were given. Interobserver variability of all cases using a 3-point scale showed fair agreement (71 %, κ{sub w} = 0.29). The conservative and sensitive analyses both showed moderate agreement: conservative approach κ = 0.44 (in 80 % of the hot foci the observers agreed) and sensitive approach κ = 0.42 (81 %) respectively. Multidisciplinary involvement in image interpretation and higher levels of observer experience appeared to increase agreement. Among 16 observers, there is practice variation in defining SLNs on lymphoscintigrams in oral cancer patients. Interobserver variability of lymphoscintigraphic interpretation shows moderate agreement. In order to achieve better agreement in defining SLNs on lymphoscintigrams specific guidelines are warranted. (orig.)

  11. Practice variation in defining sentinel lymph nodes on lymphoscintigrams in oral cancer patients

    International Nuclear Information System (INIS)

    Flach, Geke B.; Bree, Remco de; Schie, Annelies van; Hoekstra, Otto S.; Witte, Birgit I.; Olmos, Renato A.V.; Klop, W.M.C.

    2014-01-01

    Lymphoscintigraphic imaging and adequate interpretation of the lymphatic drainage pattern is an essential step in the sentinel lymph node biopsy (SLNB) procedure. In oral cancer, identification of the sentinel lymph node (SLN) can be challenging. In this study, interobserver variability in defining SLNs on lymphoscintigrams was evaluated in patients with T1-T2 stage N0 oral cancer. Sixteen observers (head and neck surgeons, nuclear medicine physicians or teams of both) from various institutes were asked which criteria they use to consider a hot focus on the lymphoscintigram as SLN. Lymphoscintigrams of 9 patients with 47 hot foci (3-9 per patient) were assessed, using a scale of 'yes/equivocal/no'. Bilateral drainage was seen in four of nine cases. In three cases additional late single photon emission computed tomography (SPECT)/CT scanning was performed. Interobserver variability was evaluated by kappa (κ) analysis, using linear weighted pairwise comparison of the observers. Conservative (equivocal analysed as no) and sensitive (equivocal analysed as yes) assessment strategies were investigated using pairwise kappa analysis. Various definitions of SLN on lymphoscintigrams were given. Interobserver variability of all cases using a 3-point scale showed fair agreement (71 %, κ w = 0.29). The conservative and sensitive analyses both showed moderate agreement: conservative approach κ = 0.44 (in 80 % of the hot foci the observers agreed) and sensitive approach κ = 0.42 (81 %) respectively. Multidisciplinary involvement in image interpretation and higher levels of observer experience appeared to increase agreement. Among 16 observers, there is practice variation in defining SLNs on lymphoscintigrams in oral cancer patients. Interobserver variability of lymphoscintigraphic interpretation shows moderate agreement. In order to achieve better agreement in defining SLNs on lymphoscintigrams specific guidelines are warranted. (orig.)

  12. Node Immunization with Time-Sensitive Restrictions

    Directory of Open Access Journals (Sweden)

    Wen Cui

    2016-12-01

    Full Text Available When we encounter a malicious rumor or an infectious disease outbreak, immunizing k nodes of the relevant network with limited resources is always treated as an extremely effective method. The key challenge is how we can insulate limited nodes to minimize the propagation of those contagious things. In previous works, the best k immunised nodes are selected by learning the initial status of nodes and their strategies even if there is no feedback in the propagation process, which eventually leads to ineffective performance of their solutions. In this paper, we design a novel vaccines placement strategy for protecting much more healthy nodes from being infected by infectious nodes. The main idea of our solution is that we are not only utilizing the status of changing nodes as auxiliary knowledge to adjust our scheme, but also comparing the performance of vaccines in various transmission slots. Thus, our solution has a better chance to get more benefit from these limited vaccines. Extensive experiments have been conducted on several real-world data sets and the results have shown that our algorithm has a better performance than previous works.

  13. DETECTION OF OCCULT LYMPH NODE TUMOR CELLS IN NODE-NEGATIVE GASTRIC CANCER PATIENTS.

    Science.gov (United States)

    Pereira, Marina Alessandra; Ramos, Marcus Fernando Kodama Pertille; Dias, Andre Roncon; Yagi, Osmar Kenji; Faraj, Sheila Friedrich; Zilberstein, Bruno; Cecconello, Ivan; Mello, Evandro Sobroza de; Ribeiro, Ulysses

    2017-01-01

    The presence of lymph nodes metastasis is one of the most important prognostic indicators in gastric cancer. The micrometastases have been studied as prognostic factor in gastric cancer, which are related to decrease overall survival and increased risk of recurrence. However, their identification is limited by conventional methodology, since they can be overlooked after routine staining. To investigate the presence of occult tumor cells using cytokeratin (CK) AE1/AE3 immunostaining in gastric cancer patients histologically lymph node negative (pN0) by H&E. Forty patients (T1-T4N0) submitted to a potentially curative gastrectomy with D2 lymphadenectomy were evaluated. The results for metastases, micrometastases and isolated tumor cells were also associated to clinicopathological characteristics and their impact on stage grouping. Tumor deposits within lymph nodes were defined according to the tumor-node-metastases guidelines (7th TNM). A total of 1439 lymph nodes were obtained (~36 per patient). Tumor cells were detected by immunohistochemistry in 24 lymph nodes from 12 patients (30%). Neoplasic cells were detected as a single or cluster tumor cells. Tumor (p=0.002), venous (p=0.016), lymphatic (p=0.006) and perineural invasions (p=0.04), as well as peritumoral lymphocytic response (p=0.012) were correlated to CK-positive immunostaining tumor cells in originally negative lymph nodes by H&E. The histologic stage of two patients was upstaged from stage IB to stage IIA. Four of the 28 CK-negative patients (14.3%) and three among 12 CK-positive patients (25%) had disease recurrence (p=0.65). The CK-immunostaining is an effective method for detecting occult tumor cells in lymph nodes and may be recommended to precisely determine tumor stage. It may be useful as supplement to H&E routine to provide better pathological staging. A presença de metástase em linfonodos é um dos indicadores prognósticos mais importantes no câncer gástrico. As micrometástases têm sido

  14. Defining nodes in complex brain networks

    Directory of Open Access Journals (Sweden)

    Matthew Lawrence Stanley

    2013-11-01

    Full Text Available Network science holds great promise for expanding our understanding of the human brain in health, disease, development, and aging. Network analyses are quickly becoming the method of choice for analyzing functional MRI data. However, many technical issues have yet to be confronted in order to optimize results. One particular issue that remains controversial in functional brain network analyses is the definition of a network node. In functional brain networks a node represents some predefined collection of brain tissue, and an edge measures the functional connectivity between pairs of nodes. The characteristics of a node, chosen by the researcher, vary considerably in the literature. This manuscript reviews the current state of the art based on published manuscripts and highlights the strengths and weaknesses of three main methods for defining nodes. Voxel-wise networks are constructed by assigning a node to each, equally sized brain area (voxel. The fMRI time-series recorded from each voxel is then used to create the functional network. Anatomical methods utilize atlases to define the nodes based on brain structure. The fMRI time-series from all voxels within the anatomical area are averaged and subsequently used to generate the network. Functional activation methods rely on data from traditional fMRI activation studies, often from databases, to identify network nodes. Such methods identify the peaks or centers of mass from activation maps to determine the location of the nodes. Small (~10-20 millimeter diameter spheres located at the coordinates of the activation foci are then applied to the data being used in the network analysis. The fMRI time-series from all voxels in the sphere are then averaged, and the resultant time series is used to generate the network. We attempt to clarify the discussion and move the study of complex brain networks forward. While the correct method to be used remains an open, possibly unsolvable question that

  15. Clearance Analysis of Node 3 Aft CBM to the Stowed FGB Solar Array

    Science.gov (United States)

    Liddle, Donn

    2014-01-01

    accuracy of the photogrammetric measurements. To verify the measured results, ISAG personnel conducted a second analysis using just the imagery of the solar arrays in an arbitrary coordinate system defined by the three corner points of the inboard-most panel, with the design distance between points A1 and A10 as the only scale. The new measurements agreed with the original results to within less than 1 in. RMS in each axis, confirming the original solar array measurements. ISAG produced a final report for the ISS Vehicle Configuration Office documenting an apparent anomaly in the retracted configuration of the port FGB solar arrays. A copy of the measurement report was translated and sent to the Russian Space Agency. During a Vehicle Integrated Performance and Resources (VIPeR) teleconference September 24, 2012, the Russians acknowledged receipt of a translated copy of the ISAG report. The Russian representative stated that the head of the solar array design team claimed that the measured configuration was impossible unless the structure was physically broken. The Russians acknowledged that they had no expertise in photogrammetry, so the analysis technique employed was a "black box" to them, and they did not know how to use the ISAG results. They asked for a single image in which the overextension of the port solar array could be obviously seen. On November 10, 2012, during a face-to-face meeting with their Russian counterparts at JSC, ISAG presented nadir-view imagery of the FGB acquired during Space Shuttle rendezvous. Using the known width of the pressurized portion of the FGB as a scale, this analysis clearly showed that the port FGB solar array was extended outboard further than the Russian design for the retracted solar array.

  16. Checkpointing for a hybrid computing node

    Science.gov (United States)

    Cher, Chen-Yong

    2016-03-08

    According to an aspect, a method for checkpointing in a hybrid computing node includes executing a task in a processing accelerator of the hybrid computing node. A checkpoint is created in a local memory of the processing accelerator. The checkpoint includes state data to restart execution of the task in the processing accelerator upon a restart operation. Execution of the task is resumed in the processing accelerator after creating the checkpoint. The state data of the checkpoint are transferred from the processing accelerator to a main processor of the hybrid computing node while the processing accelerator is executing the task.

  17. phylo-node: A molecular phylogenetic toolkit using Node.js.

    Science.gov (United States)

    O'Halloran, Damien M

    2017-01-01

    Node.js is an open-source and cross-platform environment that provides a JavaScript codebase for back-end server-side applications. JavaScript has been used to develop very fast and user-friendly front-end tools for bioinformatic and phylogenetic analyses. However, no such toolkits are available using Node.js to conduct comprehensive molecular phylogenetic analysis. To address this problem, I have developed, phylo-node, which was developed using Node.js and provides a stable and scalable toolkit that allows the user to perform diverse molecular and phylogenetic tasks. phylo-node can execute the analysis and process the resulting outputs from a suite of software options that provides tools for read processing and genome alignment, sequence retrieval, multiple sequence alignment, primer design, evolutionary modeling, and phylogeny reconstruction. Furthermore, phylo-node enables the user to deploy server dependent applications, and also provides simple integration and interoperation with other Node modules and languages using Node inheritance patterns, and a customized piping module to support the production of diverse pipelines. phylo-node is open-source and freely available to all users without sign-up or login requirements. All source code and user guidelines are openly available at the GitHub repository: https://github.com/dohalloran/phylo-node.

  18. Resilience of electricity grids against transmission line overloads under wind power injection at different nodes.

    Science.gov (United States)

    Schiel, Christoph; Lind, Pedro G; Maass, Philipp

    2017-09-14

    A steadily increasing fraction of renewable energy sources for electricity production requires a better understanding of how stochastic power generation affects the stability of electricity grids. Here, we assess the resilience of an IEEE test grid against single transmission line overloads under wind power injection based on the dc power flow equations and a quasi-static grid response to wind fluctuations. Thereby we focus on the mutual influence of wind power generation at different nodes. We find that overload probabilities vary strongly between different pairs of nodes and become highly affected by spatial correlations of wind fluctuations. An unexpected behaviour is uncovered: for a large number of node pairs, increasing wind power injection at one node can increase the power threshold at the other node with respect to line overloads in the grid. We find that this seemingly paradoxical behaviour is related to the topological distance of the overloaded line from the shortest path connecting the wind nodes. In the considered test grid, it occurs for all node pairs, where the overloaded line belongs to the shortest path.

  19. Benchmark of AC and DC Active Power Decoupling Circuits for Second-Order Harmonic Mitigation in Kilowatt-Scale Single-Phase Inverters

    DEFF Research Database (Denmark)

    Qin, Zian; Tang, Yi; Loh, Poh Chiang

    2016-01-01

    efficiency and high power density is identified and comprehensively studied, and the commercially available film capacitors, the circuit topologies, and the control strategies adopted for active power decoupling are all taken into account. Then, an adaptive decoupling voltage control method is proposed...... to further improve the performance of dc decoupling in terms of efficiency and reliability. The feasibility and superiority of the identified solution for active power decoupling together with the proposed adaptive decoupling voltage control method are finally verified by both the simulation and experimental......This paper presents the benchmark study of ac and dc active power decoupling circuits for second order harmonic mitigation in kW scale single-phase inverters. First of all, a brief comparison of recently reported active power decoupling circuits is given, and the best solution that can achieve high...

  20. Steam reforming of methane over Pt/Rh based wire mesh catalyst in single channel reformer for small scale syngas production

    DEFF Research Database (Denmark)

    Sigurdsson, Haftor Örn; Kær, Søren Knudsen

    2012-01-01

    of a catalytic parallel plate type heat exchanger (CPHE) reformer stack, where coated Pt/Rh based wire mesh is used as a catalyst. Heat is supplied to the endothermic reaction with infrared electric heaters. All the experiments were performed under atmospheric pressure and at stable operating conditions......The purpose of this study is to investigate a small scale steam methane reformer for syngas production for a micro combined heat and power (mCPH) unit under different operational conditions. The study presents an experimental analysis of the performance of a specially built single channel...... to evaluate the effect of flow maldistribution in a CPHE reformer stack on the CH4 conversion and H2 yield....

  1. Discovery, genotyping and characterization of structural variation and novel sequence at single nucleotide resolution from de novo genome assemblies on a population scale

    DEFF Research Database (Denmark)

    Liu, Siyang; Huang, Shujia; Rao, Junhua

    2015-01-01

    present a novel approach implemented in a single software package, AsmVar, to discover, genotype and characterize different forms of structural variation and novel sequence from population-scale de novo genome assemblies up to nucleotide resolution. Application of AsmVar to several human de novo genome......) as well as large deletions. However, these approaches consistently display a substantial bias against the recovery of complex structural variants and novel sequence in individual genomes and do not provide interpretation information such as the annotation of ancestral state and formation mechanism. We...... assemblies captures a wide spectrum of structural variants and novel sequences present in the human population in high sensitivity and specificity. Our method provides a direct solution for investigating structural variants and novel sequences from de novo genome assemblies, facilitating the construction...

  2. The diagnostic value of adding dynamic scintigraphy to standard delayed planar imaging for sentinel node identification in melanoma patients

    DEFF Research Database (Denmark)

    Nielsen, Marie Kristina Rue; Chakera, Annette H; Hesse, Birger

    2011-01-01

    The aim of this study was to compare early dynamic imaging combined with delayed static imaging and single photon emission computed tomography (SPECT)/CT with delayed, planar, static imaging alone for sentinel node (SN) identification in melanoma patients.......The aim of this study was to compare early dynamic imaging combined with delayed static imaging and single photon emission computed tomography (SPECT)/CT with delayed, planar, static imaging alone for sentinel node (SN) identification in melanoma patients....

  3. ARC Code TI: NodeMon

    Data.gov (United States)

    National Aeronautics and Space Administration — NodeMon is a resource utilization monitor tailored to the Altix architecture, but is applicable to any Linux system or cluster. It allows distributed resource...

  4. [Improvement of local lymph node assay for cosmetics safety evaluation].

    Science.gov (United States)

    Liu, Zhen; Liu, Junping; Wang, Fei; Xu, Guifeng; Hou, Juan; Wan, Xuying; Zhang, Tianbao

    2009-09-01

    To improve the local lymph node assay (LLNA) as an alternative method to detect chemicals for both sensitization and irritation. The following chemicals: one negative control: 4-Aminobenzoic Acid, three sensitizers: 2,4-dinitrochlorobenzene (DNCB), Hexyl cinnamic aldehyde (HCA), 2-Aminophenol (2-APC) and two irritations: potassium hydroxide (KOH), sodium lauryl sulphate (SLS) were selected. According to the normal LLNA, groups of female Balb/c mice were treated with test solutions. The thickness of each ear was measured and each auricle was weighed. On the sixth day, the bilateral draining auricular lymph nodes were excised and weighed. The single cell suspensions were prepared, the lymphocyte were counted and the proliferations of lymph cells were detected by cell counting kit-8 (CCK-8). Significant increase in ear thickness and weight were found in groups of KOH, SLS and DNCB (above 0.5%) (P LLNA using auricle thickness and weighing as observed markers for irritation, and using lymph nodes weighing and proliferation of lymphocyte as observed markers for sensitization, could evaluate both sensitization and irritation at the same time.

  5. Resilience against Misbehaving Nodes in Asynchronous Networks

    OpenAIRE

    Senejohnny, D.; Sundaram, S.; De Persis, C.; Tesi, P.

    2018-01-01

    Network systems are one of the most active research areas in the engineering community as they feature a paradigm shift from centralized to distributed control and computation. When dealing with network systems, a fundamental challenge is to ensure their functioning even when some of the network nodes do not operate as intended due to faults or attacks. The objective of this paper is to address the problem of resilient consensus in a context where the nodes have their own clocks, possibly ope...

  6. Node insertion in Coalescence Fractal Interpolation Function

    International Nuclear Information System (INIS)

    Prasad, Srijanani Anurag

    2013-01-01

    The Iterated Function System (IFS) used in the construction of Coalescence Hidden-variable Fractal Interpolation Function (CHFIF) depends on the interpolation data. The insertion of a new point in a given set of interpolation data is called the problem of node insertion. In this paper, the effect of insertion of new point on the related IFS and the Coalescence Fractal Interpolation Function is studied. Smoothness and Fractal Dimension of a CHFIF obtained with a node are also discussed

  7. Multi-attribute integrated measurement of node importance in complex networks.

    Science.gov (United States)

    Wang, Shibo; Zhao, Jinlou

    2015-11-01

    The measure of node importance in complex networks is very important to the research of networks stability and robustness; it also can ensure the security of the whole network. Most researchers have used a single indicator to measure the networks node importance, so that the obtained measurement results only reflect certain aspects of the networks with a loss of information. Meanwhile, because of the difference of networks topology, the nodes' importance should be described by combining the character of the networks topology. Most of the existing evaluation algorithms cannot completely reflect the circumstances of complex networks, so this paper takes into account the degree of centrality, the relative closeness centrality, clustering coefficient, and topology potential and raises an integrated measuring method to measure the nodes' importance. This method can reflect nodes' internal and outside attributes and eliminate the influence of network structure on the node importance. The experiments of karate network and dolphin network show that networks topology structure integrated measure has smaller range of metrical result than a single indicator and more universal. Experiments show that attacking the North American power grid and the Internet network with the method has a faster convergence speed than other methods.

  8. Lambda network having 2{sup m{minus}1} nodes in each of m stages with each node coupled to four other nodes for bidirectional routing of data packets between nodes

    Science.gov (United States)

    Napolitano, L.M. Jr.

    1995-11-28

    The Lambda network is a single stage, packet-switched interprocessor communication network for a distributed memory, parallel processor computer. Its design arises from the desired network characteristics of minimizing mean and maximum packet transfer time, local routing, expandability, deadlock avoidance, and fault tolerance. The network is based on fixed degree nodes and has mean and maximum packet transfer distances where n is the number of processors. The routing method is detailed, as are methods for expandability, deadlock avoidance, and fault tolerance. 14 figs.

  9. Lymph Node Micrometastases are Associated with Worse Survival in Patients with Otherwise Node-Negative Hilar Cholangiocarcinoma

    NARCIS (Netherlands)

    Mantel, Hendrik T. J.; Wiggers, Jim K.; Verheij, Joanne; Doff, Jan J.; Sieders, Egbert; van Gulik, Thomas M.; Gouw, Annette S. H.; Porte, Robert J.

    2015-01-01

    Background. Lymph node metastases on routine histology are a strong negative predictor for survival after resection of hilar cholangiocarcinoma. Additional immunohistochemistry can detect lymph node micrometastases in patients who are otherwise node negative, but the prognostic value is unsure. The

  10. Dynamically reassigning a connected node to a block of compute nodes for re-launching a failed job

    Science.gov (United States)

    Budnik, Thomas A [Rochester, MN; Knudson, Brant L [Rochester, MN; Megerian, Mark G [Rochester, MN; Miller, Samuel J [Rochester, MN; Stockdell, William M [Byron, MN

    2012-03-20

    Methods, systems, and products for dynamically reassigning a connected node to a block of compute nodes for re-launching a failed job that include: identifying that a job failed to execute on the block of compute nodes because connectivity failed between a compute node assigned as at least one of the connected nodes for the block of compute nodes and its supporting I/O node; and re-launching the job, including selecting an alternative connected node that is actively coupled for data communications with an active I/O node; and assigning the alternative connected node as the connected node for the block of compute nodes running the re-launched job.

  11. Subcarinal Lymph Nodes Should be Dissected in All Lobectomies for Non-Small Cell Lung Cancer

    DEFF Research Database (Denmark)

    Eckardt, Jens; Jakobsen, Erik; Licht, Peter B

    2017-01-01

    BACKGROUND: Mediastinal staging is of paramount importance for planning of treatment in non-small cell lung cancer (NSCLC). Single institution reports recently claimed that subcarinal lymph node dissection during resection of upper lobe NSCLC could be spared. We used a complete national lung cancer...... registry to investigate patterns of unsuspected mediastinal lymph node involvement after lobectomy. METHODS: During an 11-year period (2004 to 2014) 5,577 consecutive patients who underwent operations for NSCLC were investigated for unsuspected mediastinal lymph node involvement (N2 disease) discovered......: Mediastinal lymph node dissection was performed in 5,577 patients during the operation, and unsuspected N2 disease was discovered in 612 (11.0%), and 193 (3.5%) had subcarinal metastasis. Subcarinal N2 disease was significantly more common in patients with lower-lobe or middle-lobe cancers compared with upper...

  12. Dynamic scaling, data-collapse and self-similarity in Barabasi-Albert networks

    Energy Technology Data Exchange (ETDEWEB)

    Hassan, M Kamrul; Pavel, Neeaj I [Theoretical Physics Group, Department of Physics, University of Dhaka, Dhaka 1000 (Bangladesh); Hassan, M Zahedul, E-mail: khassan@univdhaka.edu [Institute of Computer Science, Bangladesh Atomic Energy Commission, Dhaka 1000 (Bangladesh)

    2011-04-29

    In this paper, we show that if each node of the Barabasi-Albert (BA) network is characterized by the generalized degree q, i.e. the product of their degree k and the square root of their respective birth time, then the distribution function F(q, t) exhibits dynamic scaling F(q, t {yields} {infinity}) {approx} t{sup -1/2}{phi}(q/t{sup 1/2}) where {phi}(x) is the scaling function. We verified it by showing that a series of distinct F(q, t) versus q curves for different network sizes N collapse onto a single universal curve if we plot t{sup 1/2}F(q, t) versus q/t{sup 1/2} instead. Finally, we show that the BA network falls into two universality classes depending on whether new nodes arrive with single edge (m = 1) or with multiple edges (m > 1).

  13. Energy, Exergy and Economic Evaluation Comparison of Small-Scale Single and Dual Pressure Organic Rankine Cycles Integrated with Low-Grade Heat Sources

    Directory of Open Access Journals (Sweden)

    Armando Fontalvo

    2017-09-01

    Full Text Available Low-grade heat sources such as solar thermal, geothermal, exhaust gases and industrial waste heat are suitable alternatives for power generation which can be exploited by means of small-scale Organic Rankine Cycle (ORC. This paper combines thermodynamic optimization and economic analysis to assess the performance of single and dual pressure ORC operating with different organic fluids and targeting small-scale applications. Maximum power output is lower than 45 KW while the temperature of the heat source varies in the range 100–200 °C. The studied working fluids, namely R1234yf, R1234ze(E and R1234ze(Z, are selected based on environmental, safety and thermal performance criteria. Levelized Cost of Electricity (LCOE and Specific Investment Cost (SIC for two operation conditions are presented: maximum power output and maximum thermal efficiency. Results showed that R1234ze(Z achieves the highest net power output (up to 44 kW when net power output is optimized. Regenerative ORC achieves the highest performance when thermal efficiency is optimized (up to 18%. Simple ORC is the most cost-effective among the studied cycle configurations, requiring a selling price of energy of 0.3 USD/kWh to obtain a payback period of 8 years. According to SIC results, the working fluid R1234ze(Z exhibits great potential for simple ORC when compared to conventional R245fa.

  14. Design and analysis of a small-scale natural gas liquefaction process adopting single nitrogen expansion with carbon dioxide pre-cooling

    International Nuclear Information System (INIS)

    Yuan, Zongming; Cui, Mengmeng; Xie, Ying; Li, Chunlin

    2014-01-01

    With the growth of energy consumption and environmental protection concerns, it is of enormous economic and environmental values for the development of stranded gas. As a means for exploitation and transportation of stranded gas to market, a novel small-scale liquefaction process adopting single nitrogen expansion with carbon dioxide pre-cooling is put up with in this paper. Taking unit energy consumption as the target function, Aspen HYSYS is employed to simulate and optimize the process to achieve the liquefaction rate of 0.77 with unit energy consumption of 9.90 kW/kmol/h. Furthermore, the adaptability of this process under different pressure, temperature and compositions of feed gas is studied. Based on the optimization results, the exergy losses of main equipment in the process are evaluated and analyzed in details. With compact device, safety operation, simple capability, this liquefaction process proves to be suitable for the development of small gas reserves, satellite distribution fields of gas or coalbed methane fields. - Highlights: •A novel small-scale liquefaction process used in stranded gas is designed. •The adaptability of this process under different pressure, temperature and compositions of feed gas is studied. •The exergy analysis of main equipment in the process is analyzed

  15. Design and analysis of a small-scale natural gas liquefaction process adopting single nitrogen expansion with carbon dioxide pre-cooling

    Energy Technology Data Exchange (ETDEWEB)

    Yuan, Zongming; Cui, Mengmeng; Xie, Ying; Li, Chunlin

    2014-03-01

    With the growth of energy consumption and environmental protection concerns, it is of enormous economic and environmental values for the development of stranded gas. As a means for exploitation and transportation of stranded gas to market, a novel small-scale liquefaction process adopting single nitrogen expansion with carbon dioxide pre-cooling is put up with in this paper. Taking unit energy consumption as the target function, Aspen HYSYS is employed to simulate and optimize the process to achieve the liquefaction rate of 0.77 with unit energy consumption of 9.90 kW/kmol/h. Furthermore, the adaptability of this process under different pressure, temperature and compositions of feed gas is studied. Based on the optimization results, the exergy losses of main equipment in the process are evaluated and analyzed in details. With compact device, safety operation, simple capability, this liquefaction process proves to be suitable for the development of small gas reserves, satellite distribution fields of gas or coalbed methane fields. - Highlights: •A novel small-scale liquefaction process used in stranded gas is designed. •The adaptability of this process under different pressure, temperature and compositions of feed gas is studied. •The exergy analysis of main equipment in the process is analyzed.

  16. Genome-wide survey of single-nucleotide polymorphisms reveals fine-scale population structure and signs of selection in the threatened Caribbean elkhorn coral, Acropora palmata

    Directory of Open Access Journals (Sweden)

    Meghann K. Devlin-Durante

    2017-11-01

    Full Text Available The advent of next-generation sequencing tools has made it possible to conduct fine-scale surveys of population differentiation and genome-wide scans for signatures of selection in non-model organisms. Such surveys are of particular importance in sharply declining coral species, since knowledge of population boundaries and signs of local adaptation can inform restoration and conservation efforts. Here, we use genome-wide surveys of single-nucleotide polymorphisms in the threatened Caribbean elkhorn coral, Acropora palmata, to reveal fine-scale population structure and infer the major barrier to gene flow that separates the eastern and western Caribbean populations between the Bahamas and Puerto Rico. The exact location of this break had been subject to discussion because two previous studies based on microsatellite data had come to differing conclusions. We investigate this contradiction by analyzing an extended set of 11 microsatellite markers including the five previously employed and discovered that one of the original microsatellite loci is apparently under selection. Exclusion of this locus reconciles the results from the SNP and the microsatellite datasets. Scans for outlier loci in the SNP data detected 13 candidate loci under positive selection, however there was no correlation between available environmental parameters and genetic distance. Together, these results suggest that reef restoration efforts should use local sources and utilize existing functional variation among geographic regions in ex situ crossing experiments to improve stress resistance of this species.

  17. Genome-wide survey of single-nucleotide polymorphisms reveals fine-scale population structure and signs of selection in the threatened Caribbean elkhorn coral, Acropora palmata.

    Science.gov (United States)

    Devlin-Durante, Meghann K; Baums, Iliana B

    2017-01-01

    The advent of next-generation sequencing tools has made it possible to conduct fine-scale surveys of population differentiation and genome-wide scans for signatures of selection in non-model organisms. Such surveys are of particular importance in sharply declining coral species, since knowledge of population boundaries and signs of local adaptation can inform restoration and conservation efforts. Here, we use genome-wide surveys of single-nucleotide polymorphisms in the threatened Caribbean elkhorn coral, Acropora palmata , to reveal fine-scale population structure and infer the major barrier to gene flow that separates the eastern and western Caribbean populations between the Bahamas and Puerto Rico. The exact location of this break had been subject to discussion because two previous studies based on microsatellite data had come to differing conclusions. We investigate this contradiction by analyzing an extended set of 11 microsatellite markers including the five previously employed and discovered that one of the original microsatellite loci is apparently under selection. Exclusion of this locus reconciles the results from the SNP and the microsatellite datasets. Scans for outlier loci in the SNP data detected 13 candidate loci under positive selection, however there was no correlation between available environmental parameters and genetic distance. Together, these results suggest that reef restoration efforts should use local sources and utilize existing functional variation among geographic regions in ex situ crossing experiments to improve stress resistance of this species.

  18. Increased cell proliferation in spleen and lymph nodes peripheral to contact allergen application site

    International Nuclear Information System (INIS)

    Chipinda, Itai; Anderson, Stacey E.; Butterworth, Leon F.; Beezhold, Donald; Siegel, Paul D.

    2009-01-01

    between the left and right side of the mouse head. Thus the contra-lateral draining superficial parotid node cannot be used as a control for application of contact allergen to a single ear in a modified LLNA

  19. Lymph Node Yield as a Predictor of Survival in Pathologically Node Negative Oral Cavity Carcinoma.

    Science.gov (United States)

    Lemieux, Aaron; Kedarisetty, Suraj; Raju, Sharat; Orosco, Ryan; Coffey, Charles

    2016-03-01

    Even after a pathologically node-negative (pN0) neck dissection for oral cavity squamous cell carcinoma (SCC), patients may develop regional recurrence. In this study, we (1) hypothesize that an increased number of lymph nodes removed (lymph node yield) in patients with pN0 oral SCC predicts improved survival and (2) explore predictors of survival in these patients using a multivariable model. Case series with chart review. Administrative database analysis. The SEER database was queried for patients diagnosed with all-stage oral cavity SCC between 1988 and 2009 who were determined to be pN0 after elective lymph node dissection. Demographic and treatment variables were extracted. The association of lymph node yield with 5-year all-cause survival was studied with multivariable survival analyses. A total of 4341 patients with pN0 oral SCC were included in this study. The 2 highest lymph node yield quartiles (representing >22 nodes removed) were found to be significant predictors of overall survival (22-35 nodes: hazard ratio [HR] = 0.854, P = .031; 36-98 nodes: HR = 0.827, P = .010). Each additional lymph node removed during neck dissection was associated with increased survival (HR = 0.995, P = .022). These data suggest that patients with oral SCC undergoing elective neck dissection may experience an overall survival benefit associated with greater lymph node yield. Mechanisms behind the demonstrated survival advantage are unknown. Larger nodal dissections may remove a greater burden of microscopic metastatic disease, diminishing the likelihood of recurrence. Lymph node yield may serve as an objective measure of the adequacy of lymphadenectomy. © American Academy of Otolaryngology—Head and Neck Surgery Foundation 2015.

  20. Scaling laws for file dissemination in P2P networks with random contacts

    NARCIS (Netherlands)

    Nunez-Queija, R.; Prabhu, B.

    2008-01-01

    In this paper we obtain the scaling law for the mean broadcast time of a file in a P2P network with an initial population of N nodes. In the model, at Poisson rate λ a node initiates a contact with another node chosen uniformly at random. This contact is said to be successful if the contacted node

  1. Implementation of Multiple Host Nodes in Wireless Sensing Node Network System for Landslide Monitoring

    International Nuclear Information System (INIS)

    Bin Abas, Faizulsalihin; Takayama, Shigeru

    2015-01-01

    This paper proposes multiple host nodes in Wireless Sensing Node Network System (WSNNS) for landslide monitoring. As landslide disasters damage monitoring system easily, one major demand in landslide monitoring is the flexibility and robustness of the system to evaluate the current situation in the monitored area. For various reasons WSNNS can provide an important contribution to reach that aim. In this system, acceleration sensors and GPS are deployed in sensing nodes. Location information by GPS, enable the system to estimate network topology and enable the system to perceive the location in emergency by monitoring the node mode. Acceleration sensors deployment, capacitate this system to detect slow mass movement that can lead to landslide occurrence. Once deployed, sensing nodes self-organize into an autonomous wireless ad hoc network. The measurement parameter data from sensing nodes is transmitted to Host System via host node and ''Cloud'' System. The implementation of multiple host nodes in Local Sensing Node Network System (LSNNS), improve risk- management of the WSNNS for real-time monitoring of landslide disaster

  2. Implementation of Multiple Host Nodes in Wireless Sensing Node Network System for Landslide Monitoring

    Science.gov (United States)

    Abas, Faizulsalihin bin; Takayama, Shigeru

    2015-02-01

    This paper proposes multiple host nodes in Wireless Sensing Node Network System (WSNNS) for landslide monitoring. As landslide disasters damage monitoring system easily, one major demand in landslide monitoring is the flexibility and robustness of the system to evaluate the current situation in the monitored area. For various reasons WSNNS can provide an important contribution to reach that aim. In this system, acceleration sensors and GPS are deployed in sensing nodes. Location information by GPS, enable the system to estimate network topology and enable the system to perceive the location in emergency by monitoring the node mode. Acceleration sensors deployment, capacitate this system to detect slow mass movement that can lead to landslide occurrence. Once deployed, sensing nodes self-organize into an autonomous wireless ad hoc network. The measurement parameter data from sensing nodes is transmitted to Host System via host node and "Cloud" System. The implementation of multiple host nodes in Local Sensing Node Network System (LSNNS), improve risk- management of the WSNNS for real-time monitoring of landslide disaster.

  3. Synchronization in node of complex networks consist of complex chaotic system

    Energy Technology Data Exchange (ETDEWEB)

    Wei, Qiang, E-mail: qiangweibeihua@163.com [Beihua University computer and technology College, BeiHua University, Jilin, 132021, Jilin (China); Digital Images Processing Institute of Beihua University, BeiHua University, Jilin, 132011, Jilin (China); Faculty of Electronic Information and Electrical Engineering, Dalian University of Technology, Dalian, 116024 (China); Xie, Cheng-jun [Beihua University computer and technology College, BeiHua University, Jilin, 132021, Jilin (China); Digital Images Processing Institute of Beihua University, BeiHua University, Jilin, 132011, Jilin (China); Liu, Hong-jun [School of Information Engineering, Weifang Vocational College, Weifang, 261041 (China); Li, Yan-hui [The Library, Weifang Vocational College, Weifang, 261041 (China)

    2014-07-15

    A new synchronization method is investigated for node of complex networks consists of complex chaotic system. When complex networks realize synchronization, different component of complex state variable synchronize up to different scaling complex function by a designed complex feedback controller. This paper change synchronization scaling function from real field to complex field for synchronization in node of complex networks with complex chaotic system. Synchronization in constant delay and time-varying coupling delay complex networks are investigated, respectively. Numerical simulations are provided to show the effectiveness of the proposed method.

  4. Value of irradiation of neck nodes metastases. Pt. 1. Treatment of palpable nodes

    International Nuclear Information System (INIS)

    Bujko, K.

    1993-01-01

    Medical records of 222 patients with neck nodes metastases from squamous cell carcinoma of supraglottic larynx, tonsil and base of tongue were analyzed. All cases were treated with definitive irradiation. 110 patients were treated with orthovoltage technique with total doses of 5000-6000 rads, 150-10 rads per fraction; 112 patients with Co-60 with total doses 6000-7000 rads, 180-230 rads per fraction. Local-regional control was achieved in 28% of cases. Failures in the neck nodes with primary tumor controlled, were recorded in 10% of patients. Failures in a primary tumor alone were observed in 26% of patients, in primary tumor and neck nodes in 36%. Radiocurability of primary tumor and involved neck nodes was similar. In cases with primary tumor controlled, the probability of eradication of neck nodes metastases is high, even in N3 stage patients. Residual neck nodes palpable 1 to 3 months after irradiation were unfavorable prognostic factor indicated 50% risk of neck recurrence. In patients with complete regression of primary and nodal disease, failure in neck nodes was recorded in 5% of cases. The role of surgery following irradiation in patients with cervical nodes metastases is discussed. (author)

  5. Measure of Node Similarity in Multilayer Networks

    DEFF Research Database (Denmark)

    Møllgaard, Anders; Zettler, Ingo; Dammeyer, Jesper

    2016-01-01

    The weight of links in a network is often related to the similarity of thenodes. Here, we introduce a simple tunable measure for analysing the similarityof nodes across different link weights. In particular, we use the measure toanalyze homophily in a group of 659 freshman students at a large...... university.Our analysis is based on data obtained using smartphones equipped with customdata collection software, complemented by questionnaire-based data. The networkof social contacts is represented as a weighted multilayer network constructedfrom different channels of telecommunication as well as data...... might bepresent in one layer of the multilayer network and simultaneously be absent inthe other layers. For a variable such as gender, our measure reveals atransition from similarity between nodes connected with links of relatively lowweight to dis-similarity for the nodes connected by the strongest...

  6. SpicyNodes Radial Map Engine

    Science.gov (United States)

    Douma, M.; Ligierko, G.; Angelov, I.

    2008-10-01

    The need for information has increased exponentially over the past decades. The current systems for constructing, exploring, classifying, organizing, and searching information face the growing challenge of enabling their users to operate efficiently and intuitively in knowledge-heavy environments. This paper presents SpicyNodes, an advanced user interface for difficult interaction contexts. It is based on an underlying structure known as a radial map, which allows users to manipulate and interact in a natural manner with entities called nodes. This technology overcomes certain limitations of existing solutions and solves the problem of browsing complex sets of linked information. SpicyNodes is also an organic system that projects users into a living space, stimulating exploratory behavior and fostering creative thought. Our interactive radial layout is used for educational purposes and has the potential for numerous other applications.

  7. [Radiotherapy in node-positive prostate cancer].

    Science.gov (United States)

    Bottke, D; Bartkowiak, D; Bolenz, C; Wiegel, T

    2016-03-01

    There are numerous randomized trials to guide the management of patients with localized (and metastatic) prostate cancer, but only a few (mostly retrospective) studies have specifically addressed node-positive patients. Therefore, there is uncertainty regarding optimal treatment in this situation. Current guidelines recommend long-term androgen deprivation therapy (ADT) alone or radiotherapy plus long-term ADT as treatment options. This overview summarizes the existing literature on the use of radiotherapy for node-positive prostate cancer as definitive treatment and as adjuvant or salvage therapy after radical prostatectomy. In this context, we also discuss several PET tracers in the imaging evaluation of patients with biochemical recurrence of prostate cancer after radical prostatectomy. As for definitive treatment, retrospective studies suggest that ADT plus radiotherapy improves overall survival compared with ADT alone. These studies also consistently demonstrated that many patients with node-positive prostate cancer can achieve long-term survival - and are likely curable - with aggressive therapy. The beneficial impact of adjuvant radiotherapy on survival in patients with pN1 prostate cancer seems to be highly influenced by tumor characteristics. Men with ≤ 2 positive lymph nodes in the presence of intermediate- to high-grade disease, or positive margins, and those with 3 or 4 positive lymph nodes are the ideal candidates for adjuvant radiotherapy (plus long-term ADT) after surgery. There is a need for randomized trials to further examine the potential role of radiotherapy as either definitive or adjuvant treatment, for patients with node-positive prostate cancer.

  8. Counterpart synchronization of duplex networks with delayed nodes and noise perturbation

    International Nuclear Information System (INIS)

    Wei, Xiang; Wu, Xiaoqun; Lu, Jun-an; Zhao, Junchan

    2015-01-01

    In the real world, many complex systems are represented not by single networks but rather by sets of interdependent ones. In these specific networks, nodes in one network mutually interact with nodes in other networks. This paper focuses on a simple representative case of two-layer networks (the so-called duplex networks) with unidirectional inter-layer couplings. That is, each node in one network depends on a counterpart in the other network. Accordingly, the former network is called the response layer and the latter network is the drive layer. Specifically, synchronization between each node in the drive layer and its counterpart in the response layer (counterpart synchronization (CS)) in these kinds of duplex networks with delayed nodes and noise perturbation is investigated. Based on the LaSalle-type invariance principle, a control technique is proposed and a sufficient condition is developed for realizing CS of duplex networks. Furthermore, two corollaries are derived as special cases. In addition, node dynamics within each layer can be varied and topologies of the two layers are not necessarily identical. Therefore, the proposed synchronization method can be applied to a wide range of multiplex networks. Numerical examples are provided to illustrate the feasibility and effectiveness of the results. (paper)

  9. A wireless vibrating wire sensor node for continuous structural health monitoring

    International Nuclear Information System (INIS)

    Lee, H M; Park, H S; Kim, J M; Sho, K

    2010-01-01

    Vibrating wire sensors (VWS) are generally used for strain measurements of structures in buildings and civil infrastructures. In this paper, a wireless vibrating wire sensor node is developed which can measure resonance frequencies from vibrating wire sensors and can remotely communicate the frequencies by wireless. The wireless sensor node consists of a sensor module, which excites the vibrating wire and reads the resonance frequencies, a wireless communication module, which transmits the wire's resonance frequencies to the user or administrator, and a processor that controls the two modules. The wireless sensor node has the following characteristics: it has multiple channels to enable measurement of multiple vibrating wire sensors (up to four) using a single sensor node; it has a power-saving feature that enables operation for up to one year; and lastly, the wireless unit uses the 424 MHz UHF (ultra-high frequency) band with good diffraction that has an effect on minimizing the influence of impediments such as structural or nonstructural elements. The wireless sensor node is tested in terms of its measurement precision and its wireless communication performance. As a result, it is confirmed that the node enables the long-term structural health monitoring of buildings and infrastructures

  10. Towards Interactive, Incremental Programming of ROS Nodes

    DEFF Research Database (Denmark)

    Adam, Marian Sorin; Schultz, Ulrik Pagh

    Writing software for controlling robots is a complex task, usually demanding command of many programming languages and requiring significant experimentation. We believe that a bottom-up development process that complements traditional component- and MDSD-based approaches can facilitate...... experimentation. We propose the use of an internal DSL providing both a tool to interactively create ROS nodes and a behaviour-replacement mechanism to interactively reshape existing ROS nodes by wrapping the external interfaces (the publish/subscribe topics), dynamically controlled using the Python command line...

  11. Refining Nodes and Edges of State Machines

    DEFF Research Database (Denmark)

    Hallerstede, Stefan; Snook, Colin

    2011-01-01

    State machines are hierarchical automata that are widely used to structure complex behavioural specifications. We develop two notions of refinement of state machines, node refinement and edge refinement. We compare the two notions by means of examples and argue that, by adopting simple conventions...... refinement theory and UML-B state machine refinement influences the style of node refinement. Hence we propose a method with direct proof of state machine refinement avoiding the detour via Event-B that is needed by UML-B....

  12. Simultaneous dual pathology in lymph node

    Directory of Open Access Journals (Sweden)

    Prakas Kumar Mandal

    2014-05-01

    Full Text Available [Abstract] Tubercuous lymphadenitis and Non Hodgkins’ Lymphoma are common in India. As both diseases can occur in elderly persons there is a definite chance of co-existence of both diseases; but that coexistence has not been reported. Here we present a unique case in an elderly woman who had synchronous double pathology of tuberculosis (TB and Diffuse Large B cell Lymphoma (DLBCL of the lymph nodes.     Key words:- lymph nodes, tuberculosis (TB, Diffuse Large B cell Lymphoma (DLBCL.

  13. Magnetization of topological line-node semimetals

    Science.gov (United States)

    Mikitik, G. P.; Sharlai, Yu. V.

    2018-02-01

    Using an approximate expression for the Landau levels of the electrons located near a nodal line of a topological line-node semimetal, we obtain formulas for the magnetization of this semimetal at an arbitrary shape of its line. It is also shown that the dependence of the chemical potential on the magnetic field can be strong in these materials, and this dependence can essentially influence the de Haas-van Alphen oscillations. The obtained results are applied to the rhombohedral graphite, which is one of the line-node semimetals. For this material, we find temperature and magnetic field dependencies of its magnetic susceptibility.

  14. Measure of Node Similarity in Multilayer Networks

    DEFF Research Database (Denmark)

    Møllgaard, Anders; Zettler, Ingo; Dammeyer, Jesper

    2016-01-01

    university.Our analysis is based on data obtained using smartphones equipped with customdata collection software, complemented by questionnaire-based data. The networkof social contacts is represented as a weighted multilayer network constructedfrom different channels of telecommunication as well as data...... might bepresent in one layer of the multilayer network and simultaneously be absent inthe other layers. For a variable such as gender, our measure reveals atransition from similarity between nodes connected with links of relatively lowweight to dis-similarity for the nodes connected by the strongest...

  15. Distribution of prostate nodes: a PET/CT-derived anatomic atlas of prostate cancer patients before and after surgical treatment.

    Science.gov (United States)

    Hegemann, Nina-Sophie; Wenter, Vera; Spath, Sonja; Kusumo, Nadia; Li, Minglun; Bartenstein, Peter; Fendler, Wolfgang P; Stief, Christian; Belka, Claus; Ganswindt, Ute

    2016-03-11

    In order to define adequate radiation portals in nodal positive prostate cancer a detailed knowledge of the anatomic lymph-node distribution is mandatory. We therefore systematically analyzed the localization of Choline PET/CT positive lymph nodes and compared it to the RTOG recommendation of pelvic CTV, as well as to previous work, the SPECT sentinel lymph node atlas. Thirty-two patients being mostly high risk patients with a PSA of 12.5 ng/ml (median) received PET/CT before any treatment. Eighty-seven patients received PET/CT for staging due to biochemical failure with a median PSA of 3.12 ng/ml. Each single PET-positive lymph node was manually contoured in a "virtual" patient dataset to achieve a 3-D visualization, resulting in an atlas of the cumulative PET positive lymph node distribution. Further the PET-positive lymph node location in each patient was assessed with regard to the existence of a potential geographic miss (i.e. PET-positive lymph nodes that would not have been treated adequately by the RTOG consensus on CTV definition of pelvic lymph nodes). Seventy-eight and 209 PET positive lymph nodes were detected in patients with no prior treatment and in postoperative patients, respectively. The most common sites of PET positive lymph nodes in patients with no prior treatment were external iliac (32.1 %), followed by common iliac (23.1 %) and para-aortic (19.2 %). In postoperative patients the most common sites of PET positive lymph nodes were common iliac (24.9 %), followed by external iliac (23.0 %) and para-aortic (20.1 %). In patients with no prior treatment there were 34 (43.6 %) and in postoperative patients there were 77 (36.8 %) of all detected lymph nodes that would not have been treated adequately using the RTOG CTV. We compared the distribution of lymph nodes gained by Choline PET/CT to the preexisting SPECT sentinel lymph node atlas and saw an overall good congruence. Choline PET/CT and SPECT sentinel lymph node atlas are comparable to each

  16. Distributed Processing Using Single-chip Microcomputers

    National Research Council Canada - National Science Library

    Pritchett, William

    1996-01-01

    This project investigates the use of single-chip microprocessors as nodes in a token ring control network and explores the implementation of a protocol to manage communication across such a network...

  17. Developmental and Subcellular Organization of Single-Cell C₄ Photosynthesis in Bienertia sinuspersici Determined by Large-Scale Proteomics and cDNA Assembly from 454 DNA Sequencing.

    Science.gov (United States)

    Offermann, Sascha; Friso, Giulia; Doroshenk, Kelly A; Sun, Qi; Sharpe, Richard M; Okita, Thomas W; Wimmer, Diana; Edwards, Gerald E; van Wijk, Klaas J

    2015-05-01

    Kranz C4 species strictly depend on separation of primary and secondary carbon fixation reactions in different cell types. In contrast, the single-cell C4 (SCC4) species Bienertia sinuspersici utilizes intracellular compartmentation including two physiologically and biochemically different chloroplast types; however, information on identity, localization, and induction of proteins required for this SCC4 system is currently very limited. In this study, we determined the distribution of photosynthesis-related proteins and the induction of the C4 system during development by label-free proteomics of subcellular fractions and leaves of different developmental stages. This was enabled by inferring a protein sequence database from 454 sequencing of Bienertia cDNAs. Large-scale proteome rearrangements were observed as C4 photosynthesis developed during leaf maturation. The proteomes of the two chloroplasts are different with differential accumulation of linear and cyclic electron transport components, primary and secondary carbon fixation reactions, and a triose-phosphate shuttle that is shared between the two chloroplast types. This differential protein distribution pattern suggests the presence of a mRNA or protein-sorting mechanism for nuclear-encoded, chloroplast-targeted proteins in SCC4 species. The combined information was used to provide a comprehensive model for NAD-ME type carbon fixation in SCC4 species.

  18. Proposal for a Full-Scale Prototype Single-Phase Liquid Argon Time Projection Chamber and Detector Beam Test at CERN

    CERN Document Server

    Kutter, T

    2015-01-01

    The Deep Underground Neutrino Experiment (DUNE) will use a large liquid argon (LAr) detector to measure the CP violating phase, determine the neutrino mass hier- archy and perform precision tests of the three-flavor paradigm in long-baseline neutrino oscillations. The detector will consist of four modules each with a fiducial mass of 10 kt of LAr and due to its unprecedented size will allow sensitive searches for proton decay and the detection and measurement of electron neutrinos from core collapse supernovae [1]. The first 10 kt module will use single-phase LAr detection technique and be itself modular in design. The successful manufacturing, installation and operation of several full-scale detector components in a suitable configuration represents a critical engineering milestone prior to the construction and operation of the first full 10 kt DUNE detector module at the SURF underground site. A charged particle beam test of a prototype detector will provide critical calibration measurements as well as inva...

  19. Concurrent validity and sensitivity to change of Direct Behavior Rating Single-Item Scales (DBR-SIS) within an elementary sample.

    Science.gov (United States)

    Smith, Rhonda L; Eklund, Katie; Kilgus, Stephen P

    2018-03-01

    The purpose of this study was to evaluate the concurrent validity, sensitivity to change, and teacher acceptability of Direct Behavior Rating single-item scales (DBR-SIS), a brief progress monitoring measure designed to assess student behavioral change in response to intervention. Twenty-four elementary teacher-student dyads implemented a daily report card intervention to promote positive student behavior during prespecified classroom activities. During both baseline and intervention, teachers completed DBR-SIS ratings of 2 target behaviors (i.e., Academic Engagement, Disruptive Behavior) whereas research assistants collected systematic direct observation (SDO) data in relation to the same behaviors. Five change metrics (i.e., absolute change, percent of change from baseline, improvement rate difference, Tau-U, and standardized mean difference; Gresham, 2005) were calculated for both DBR-SIS and SDO data, yielding estimates of the change in student behavior in response to intervention. Mean DBR-SIS scores were predominantly moderately to highly correlated with SDO data within both baseline and intervention, demonstrating evidence of the former's concurrent validity. DBR-SIS change metrics were also significantly correlated with SDO change metrics for both Disruptive Behavior and Academic Engagement, yielding evidence of the former's sensitivity to change. In addition, teacher Usage Rating Profile-Assessment (URP-A) ratings indicated they found DBR-SIS to be acceptable and usable. Implications for practice, study limitations, and areas of future research are discussed. (PsycINFO Database Record (c) 2018 APA, all rights reserved).

  20. New approach to the dosimetry of ionizing radiations by fluorescence measurement, according to the single photon counting technique, correlated in time at the nanosecond scale

    International Nuclear Information System (INIS)

    Sohier, Till

    2011-01-01

    This research thesis reports the first fundamental study of the dosimetry of charged and gamma radiations by measurement of fluorescence resolved in time at a nanosecond scale, in organic matter. This method allows an in-depth and real-time analysis of the deposited dose, while taking ionisation as well as excitation processes into account. The author describes mechanisms of interaction and deposition of energy on dense matter, reports the detailed study of the ion-matter interaction, and the interaction of secondary electrons produced within traces. He addresses mechanisms of energy relaxation, and more particularly the study or organic scintillators. Then, he presents the adopted experimental approach: experimental observation with a statistic reconstitution of the curve representing the intensity of the emitted fluorescence in time and with a nanosecond resolution by using a scintillating sensor for time correlated single photon counting (TCSPC). The next part reports the development of an experimental multi-modal platform for dosimetry by TCSPC aimed at the measurement of fluorescence decays under pulsed excitation (nanosecond pulsed ion beams) and continuous flow excitation (non pulsed beams and radioactive sources). Experimental results are then presented for fluorescence measurements, and compared with measurements obtained by using an ionization chamber under the same irradiation conditions: dose deposited by hellions and carbon ions within polyvinyl toluene and polyethylene terephthalate, use of scintillating optic fibers under gamma irradiation of Caesium 137 and Cobalt 60. A new experimental approach is finally presented to perform dosimetry measurements while experimentally ignoring luminescence produced by Cerenkov effect [fr

  1. Control range: a controllability-based index for node significance in directed networks

    International Nuclear Information System (INIS)

    Wang, Bingbo; Gao, Lin; Gao, Yong

    2012-01-01

    While a large number of methods for module detection have been developed for undirected networks, it is difficult to adapt them to handle directed networks due to the lack of consensus criteria for measuring the node significance in a directed network. In this paper, we propose a novel structural index, the control range, motivated by recent studies on the structural controllability of large-scale directed networks. The control range of a node quantifies the size of the subnetwork that the node can effectively control. A related index, called the control range similarity, is also introduced to measure the structural similarity between two nodes. When applying the index of control range to several real-world and synthetic directed networks, it is observed that the control range of the nodes is mainly influenced by the network's degree distribution and that nodes with a low degree may have a high control range. We use the index of control range similarity to detect and analyze functional modules in glossary networks and the enzyme-centric network of homo sapiens. Our results, as compared with other approaches to module detection such as modularity optimization algorithm, dynamic algorithm and clique percolation method, indicate that the proposed indices are effective and practical in depicting structural and modular characteristics of sparse directed networks

  2. Power/Energy Estimator for Designing WSN Nodes with Ambient Energy Harvesting Feature

    Directory of Open Access Journals (Sweden)

    Jutel Dominique

    2011-01-01

    Full Text Available Abstract Wireless Sensor Networks (WSNs consist of spatially distributed autonomous sensors to cooperatively monitor physical conditions. Thus, the node battery autonomy is critical. To outperform it, most WSNs rely on the harvesting capability. As nodes can recharge whenever energy is available, the problem is to determine at design time the node autonomy. For our project, we solve it by creating a power/energy estimator that simulates business scenarios to predict node autonomy; the estimation concerns both power and energy features. Based on node architecture configuration, its Dynamic Power Management (DPM policy, and environmental conditions, we present a simulator that helps identify power consumption hot spots and make critical choices during the system design. It also helps to scale the energy storage system as well as the energy harvesters correctly. The hardware part is modelled using the FLPA methodology to develop different node component models with a variable accuracy. For the logical part, we developped a specific DPM by integrating meteorology and weather forecast behaviours. The novelty comes from the ability to simulate the WSN harvesting capability and to estimate at runtime the remaining duration of each service.

  3. [Pay attention to the selective lateral pelvic lymph node dissection in mid-low rectal cancer].

    Science.gov (United States)

    Meng, Wenjian; Wang, Ziqiang

    2017-03-25

    Lateral pelvic lymph node metastasis is an important metastatic mode and a major cause of locoregional recurrence of mid-low rectal cancer. Recently, there is an East-West discrepancy in regard to the diagnosis, clinical significance, treatment and prognosis of lateral pelvic lymph node metastasis. In the West, lateral nodal involvement may represent systemic disease and preoperative chemoradiotherapy can sterilize clinically suspected lateral nodes. Thus, in many Western countries, the standard therapy for lower rectal cancer is total mesorectal excision with chemoradiotherapy, and pelvic sidewall dissection is rarely performed. In the East, and Japan in particular, however, there is a positive attitude in regard to lateral pelvic lymph node dissection (LPND). They consider that lateral pelvic lymph node metastasis is as regional metastasis, and the clinically suspected lateral nodes can not be removed by neoadjuvant chemoradiotherapy. The selective LPND after neoadjuvant chemoradiotherapy may be found to be promising treatment for the improvement of therapeutic benefits in these patients. Therefore, the large-scale prospective studies are urgently required to improve selection criteria for LPND and neoadjuvant treatment to prevent overtreatment in the near future. Selective LPND after neoadjuvant treatment based on modern imaging techniques is expected to reduce locoregional recurrence and improve long-term survival in patients with mid-low rectal cancer.

  4. Detection of sentinel nodes with radiopharmaceuticals

    International Nuclear Information System (INIS)

    Yokoyama, Kunihiko; Michigishi, Takatoshi; Kinuya, Seigo; Konishi, Shota; Nakajima, Kenichi; Tonami, Norihisa

    2000-01-01

    Sentinel lymph nodes have been found to be an indicator of lymph node metastasis in breast cancer. In Japan, the theory and concept of sentinel lymph nodes in breast cancer have begun to be applied to carcinomas of the digestive system. Based on clinical experience in the detection of sentinel lymph nodes with radiopharmaceuticals, differences and similarities between the radiopharmaceuticals, methods, and techniques used to detect sentinel lymph nodes have been assessed in relation to breast cancer and carcinomas of the digestive system (including carcinomas of the esophagus and large intestine). The greatest difference between the methods used for breast and digestive cancers is the site of administration of the radiopharmaceutical. In breast cancer, the radiopharmaceutical is administered into a superficial organ (i.e., the mammary gland), whereas in carcinomas of the digestive system, it is administered into a deep organ (i.e., digestive tract). Another obvious difference is in lymph flow, i.e., the flow of the mammary glands is subcutaneous whereas lymph flow in the digestive tract is submucosal. Two radionuclide diagnostic methods are available to detect sentinel lymph nodes: sentinel lymphoscintigraphy with a gamma camera and a method that involves the use of a gamma probe intraoperatively. Radiopharmaceuticals used to detect sentinel lymph nodes must be smoothly transferred from the site of administration into the lymph, and uptake by the sentinel lymph node must continue for a long time without excessive flowing to lower reaches. The optimal particle size remains a matter of controversy, and no radiopharmaceuticals appropriate for lymphoscintigraphy have ever been approved in Japan. The authors compared the pharmacokinetics of three different radiopharmaceuticals used for sentinel lymphoscintigraphy in breast cancer ( 99m Tc-labeled albumin, 99m Tc-labeled tin colloid, and 99m Tc-labeled phytic acid) and founded that the detection rate was lowest with

  5. Lymphatic drainage and sentinel node location in breast cancer

    International Nuclear Information System (INIS)

    Uren, R.F.; Howman-Giles, R.B.; Roberts, J.; Renwick, S.; Gillett, D.; Neische, F.; Ramsay-Stewart, G.

    1999-01-01

    Full text: Mammary lymphoscintigraphy using small volume (0.1-0.2 ml) peritumoral injections of 99 Tc m -antimony sulphide colloid provided a map of the lymph drainage of a breast cancer to its draining sentinel lymph nodes in 92 of 102 patients (over 90%). Non-migration of tracer is reduced by post-injection massage for 5 min but may occur especially if the lymphatics are blocked by metastases. Drainage included the axilla in 92%, internal mammary nodes in 43%, supraclavicular nodes in 12% and intramammary interval nodes in 10% of patients. One patient drained to an interpectoral node. Drainage across the centre-line of the breast occurred in 46% of patients but direct drainage to the contralateral side of the patient was not seen. Lymphatic drainage occurred to 1 node field in 52 patients, 2 node fields in 34 patients and 3 node fields in 6 patients, so that 43% of patients had multiple draining node fields. Drainage to non-axillary sites occurred in 51% of patients. In conclusion, mammary lymphoscintigraphy accurately maps sentinel node location in breast cancer. Approximately half of the patients will have sentinel nodes outside the axilla. To achieve complete lymph node staging in patients with breast cancer, it is logical to biopsy these non-axillary sentinel nodes as well as the sentinel nodes in the axilla. Failure to do so will potentially understage the node status in 50% of patients

  6. Distribution of shortest path lengths in a class of node duplication network models

    Science.gov (United States)

    Steinbock, Chanania; Biham, Ofer; Katzav, Eytan

    2017-09-01

    We present analytical results for the distribution of shortest path lengths (DSPL) in a network growth model which evolves by node duplication (ND). The model captures essential properties of the structure and growth dynamics of social networks, acquaintance networks, and scientific citation networks, where duplication mechanisms play a major role. Starting from an initial seed network, at each time step a random node, referred to as a mother node, is selected for duplication. Its daughter node is added to the network, forming a link to the mother node, and with probability p to each one of its neighbors. The degree distribution of the resulting network turns out to follow a power-law distribution, thus the ND network is a scale-free network. To calculate the DSPL we derive a master equation for the time evolution of the probability Pt(L =ℓ ) , ℓ =1 ,2 ,⋯ , where L is the distance between a pair of nodes and t is the time. Finding an exact analytical solution of the master equation, we obtain a closed form expression for Pt(L =ℓ ) . The mean distance 〈L〉 t and the diameter Δt are found to scale like lnt , namely, the ND network is a small-world network. The variance of the DSPL is also found to scale like lnt . Interestingly, the mean distance and the diameter exhibit properties of a small-world network, rather than the ultrasmall-world network behavior observed in other scale-free networks, in which 〈L〉 t˜lnlnt .

  7. Sentinel node biopsy and concomitant probe-guided tumor excision of nonpalpable breast cancer

    NARCIS (Netherlands)

    van Rijk, Maartje C.; Tanis, Pieter J.; Nieweg, Omgo E.; Loo, Claudette E.; Valdés Olmos, Renato A.; Oldenburg, Hester S. A.; Rutgers, Emiel J. Th; Hoefnagel, Cornelis A.; Kroon, Bin B. R.

    2007-01-01

    BACKGROUND: Preliminary data have shown encouraging results of a single intratumoral radiopharmaceutical injection that enables both sentinel node biopsy and probe-guided excision of the primary tumor in patients with nonpalpable breast cancer. The aim of the study was to evaluate this approach in a

  8. Adaptive control of structural balance for complex dynamical networks based on dynamic coupling of nodes

    Science.gov (United States)

    Gao, Zilin; Wang, Yinhe; Zhang, Lili

    2018-02-01

    In the existing research results of the complex dynamical networks controlled, the controllers are mainly used to guarantee the synchronization or stabilization of the nodes’ state, and the terms coupled with connection relationships may affect the behaviors of nodes, this obviously ignores the dynamic common behavior of the connection relationships between the nodes. In fact, from the point of view of large-scale system, a complex dynamical network can be regarded to be composed of two time-varying dynamic subsystems, which can be called the nodes subsystem and the connection relationships subsystem, respectively. Similar to the synchronization or stabilization of the nodes subsystem, some characteristic phenomena can be also emerged in the connection relationships subsystem. For example, the structural balance in the social networks and the synaptic facilitation in the biological neural networks. This paper focuses on the structural balance in dynamic complex networks. Generally speaking, the state of the connection relationships subsystem is difficult to be measured accurately in practical applications, and thus it is not easy to implant the controller directly into the connection relationships subsystem. It is noted that the nodes subsystem and the relationships subsystem are mutually coupled, which implies that the state of the connection relationships subsystem can be affected by the controllable state of nodes subsystem. Inspired by this observation, by using the structural balance theory of triad, the controller with the parameter adaptive law is proposed for the nodes subsystem in this paper, which may ensure the connection relationship matrix to approximate a given structural balance matrix in the sense of the uniformly ultimately bounded (UUB). That is, the structural balance may be obtained by employing the controlling state of the nodes subsystem. Finally, the simulations are used to show the validity of the method in this paper.

  9. Measure of Node Similarity in Multilayer Networks.

    Directory of Open Access Journals (Sweden)

    Anders Mollgaard

    Full Text Available The weight of links in a network is often related to the similarity of the nodes. Here, we introduce a simple tunable measure for analysing the similarity of nodes across different link weights. In particular, we use the measure to analyze homophily in a group of 659 freshman students at a large university. Our analysis is based on data obtained using smartphones equipped with custom data collection software, complemented by questionnaire-based data. The network of social contacts is represented as a weighted multilayer network constructed from different channels of telecommunication as well as data on face-to-face contacts. We find that even strongly connected individuals are not more similar with respect to basic personality traits than randomly chosen pairs of individuals. In contrast, several socio-demographics variables have a significant degree of similarity. We further observe that similarity might be present in one layer of the multilayer network and simultaneously be absent in the other layers. For a variable such as gender, our measure reveals a transition from similarity between nodes connected with links of relatively low weight to dis-similarity for the nodes connected by the strongest links. We finally analyze the overlap between layers in the network for different levels of acquaintanceships.

  10. Network Design with Node Degree Balance Constraints

    DEFF Research Database (Denmark)

    Pedersen, Michael Berliner; Crainic, Teodor Gabriel

    This presentation discusses an extension to the network design model where there in addition to the flow conservation constraints also are constraints that require design conservation. This means that the number of arcs entering and leaving a node must be the same. As will be shown the model has ...

  11. Penile lymphoscintigraphy for sentinel node identification

    International Nuclear Information System (INIS)

    Valdes Olmos, R.A.; Hoefnagel, C.A.; Tanis, P.J.; Jansen, L.; Nieweg, O.E.; Meinhardt, W.; Horenblas, S.

    2001-01-01

    Lymphoscintigraphy for sentinel node (SN) identification has been extensively validated in breast cancer and melanoma. The aim of this study was to evaluate the findings of lymphoscintigraphy for SN identification in carcinoma of the penis. Lymphoscintigraphy was performed in 74 consecutive patients (mean age 62.2 years, range 28-87 years) with clinically lymph node-negative squamous cell carcinoma of the penis (stage T2 or greater). Following local anaesthesia by xy-locaine 10% spray, technetium-99m nanocolloid (mean dose 64.8 MBq, range 40-131 MBq) in a volume of 0.3-0.4 ml was injected intradermally around the tumour. Shortly after injection, a 20-min dynamic study was performed with a dual-head gamma camera; subsequently, static anterior and lateral images were obtained at 30 min and 2 h using simultaneous cobalt-57 flood source transmission scanning. 57 Co-assisted skin marking defined SN location for gamma probe/blue dye-guided biopsy, which was performed the next day. The SN visualization rate was 97% (72/74). Lymphatic drainage was bilateral in 81% of the cases (58/72), exclusively to the left groin in 13% (9/72) and only to the right groin in 6%. Bilateral lymph node drainage was synchronous in 38% (22/58) and asynchronous in 62% (in 18 patients the initial route was the left groin, and in the other 18, the right groin). Visualization before 30 min occurred in 66 patients (93%), in 64 of them (88%) already during the dynamic study. A total of 173 SNs were visualized (85 in the right groin, 88 in the left groin). Pitfalls were caused by inguinal skin contamination during injection (four patients) and intracavernous administration (one patient). At surgery, a total of 161 SNs were identified and removed. Sixteen patients (22%) had a tumour-positive SN and underwent standard regional lymph node dissection subsequently. During follow-up (median 28 months, range 3-74 months), two patients with a negative SN developed lymph node metastases in the mapped basin

  12. Penile lymphoscintigraphy for sentinel node identification

    Energy Technology Data Exchange (ETDEWEB)

    Valdes Olmos, R.A.; Hoefnagel, C.A. [Netherlands Cancer Inst., Amsterdam (Netherlands). Dept. of Nuclear Medicine; Tanis, P.J.; Jansen, L.; Nieweg, O.E. [Netherlands Cancer Inst., Amsterdam (Netherlands). Dept. of Surgery; Meinhardt, W.; Horenblas, S. [Netherlands Cancer Inst., Amsterdam (Netherlands). Dept. of Urology

    2001-05-01

    Lymphoscintigraphy for sentinel node (SN) identification has been extensively validated in breast cancer and melanoma. The aim of this study was to evaluate the findings of lymphoscintigraphy for SN identification in carcinoma of the penis. Lymphoscintigraphy was performed in 74 consecutive patients (mean age 62.2 years, range 28-87 years) with clinically lymph node-negative squamous cell carcinoma of the penis (stage T2 or greater). Following local anaesthesia by xy-locaine 10% spray, technetium-99m nanocolloid (mean dose 64.8 MBq, range 40-131 MBq) in a volume of 0.3-0.4 ml was injected intradermally around the tumour. Shortly after injection, a 20-min dynamic study was performed with a dual-head gamma camera; subsequently, static anterior and lateral images were obtained at 30 min and 2 h using simultaneous cobalt-57 flood source transmission scanning. {sup 57}Co-assisted skin marking defined SN location for gamma probe/blue dye-guided biopsy, which was performed the next day. The SN visualization rate was 97% (72/74). Lymphatic drainage was bilateral in 81% of the cases (58/72), exclusively to the left groin in 13% (9/72) and only to the right groin in 6%. Bilateral lymph node drainage was synchronous in 38% (22/58) and asynchronous in 62% (in 18 patients the initial route was the left groin, and in the other 18, the right groin). Visualization before 30 min occurred in 66 patients (93%), in 64 of them (88%) already during the dynamic study. A total of 173 SNs were visualized (85 in the right groin, 88 in the left groin). Pitfalls were caused by inguinal skin contamination during injection (four patients) and intracavernous administration (one patient). At surgery, a total of 161 SNs were identified and removed. Sixteen patients (22%) had a tumour-positive SN and underwent standard regional lymph node dissection subsequently. During follow-up (median 28 months, range 3-74 months), two patients with a negative SN developed lymph node metastases in the mapped

  13. A self-supporting wireless IoT node that uses kinetic energy harvesting

    DEFF Research Database (Denmark)

    Lynggaard, Per

    2017-01-01

    The Internet-of-Things (IoT) is expected to be the next revolution of the internet where trillions of IoT nodes will be deployed on a global scale. It is foreseen that a considerable part of these will be deployed in smart buildings and smart homes where they will provide innovative solutions...

  14. Post-operative Pain Analysis between Single Visit and Two Visit Root Canal Treatments using Visual Analogue Scale: An In Vivo Study

    Directory of Open Access Journals (Sweden)

    Kavita Tarale

    2013-01-01

    Full Text Available The purpose of this clinical study was to evaluate post-operative pain, after root canal therapy, performed in one appointment versus two appointment using calcium hydroxide intracanal medicament. Study design: In this in-vivo study, 60 patients requiring root canal therapy on permanent 1st molars were included. Patients were randomly divided into two experimental and one control group. Group1: One visit therapy (n=20 Group2: Two visit therapy with 1 week of calcium hydroxide dressing (n=20 Group3(Control: Two visit therapy with 1 week of sterile dry cotton pellet dressing (n=20 Materials and method : The standard protocol for all the patients included local anaesthesia, isolation & access cavity preparation, chemomechanical preparation with Rotary Protaper NiTi instruments, and irrigation with 3% sodium hypochlorite, 17% EDTA, 0.9%saline and 2% chlorhexidine. Teeth in group1 (n=20 were obturated on the same appointment using single cone technique (6% gutta percha points and AH Plus sealer. Teeth in group 2(n=20 and group 3(n=20 were given a dressing of calcium hydroxide and dry cotton pellet respectively for a week followed by double seal with Cavit G and IRM. These teeth were obturated on the 2nd appointment using same material and techniques as in group 1. Teeth in all three groups were restored with dual cure composite resin. A modified Visual Analogue Scale was used to measure preoperative pain and postoperative pain after 6, 12, 24 & 48hrs interval. Statistical analysis was performed using an independent-sample t test. There was no statistically significant difference between groups at any of the four postoperative intervals. There was no significant difference among all the three groups studied after 12, 24hrs & 48hrs. Conclusion : Within the limitations of this in vivo study, it may be concluded that Single Visit Endodontics provides excellent results, if care in diagnosis and proper case selection is given importance. Calcium hydroxide

  15. Mining Important Nodes in Directed Weighted Complex Networks

    Directory of Open Access Journals (Sweden)

    Yunyun Yang

    2017-01-01

    Full Text Available In complex networks, mining important nodes has been a matter of concern by scholars. In recent years, scholars have focused on mining important nodes in undirected unweighted complex networks. But most of the methods are not applicable to directed weighted complex networks. Therefore, this paper proposes a Two-Way-PageRank method based on PageRank for further discussion of mining important nodes in directed weighted complex networks. We have mainly considered the frequency of contact between nodes and the length of time of contact between nodes. We have considered the source of the nodes (in-degree and the whereabouts of the nodes (out-degree simultaneously. We have given node important performance indicators. Through numerical examples, we analyze the impact of variation of some parameters on node important performance indicators. Finally, the paper has verified the accuracy and validity of the method through empirical network data.

  16. Lack of replication of thirteen single-nucleotide polymorphisms implicated in Parkinson’s disease: a large-scale international study

    Science.gov (United States)

    Elbaz, Alexis; Nelson, Lorene M; Payami, Haydeh; Ioannidis, John P A; Fiske, Brian K; Annesi, Grazia; Belin, Andrea Carmine; Factor, Stewart A; Ferrarese, Carlo; Hadjigeorgiou, Georgios M; Higgins, Donald S; Kawakami, Hideshi; Krüger, Rejko; Marder, Karen S; Mayeux, Richard P; Mellick, George D; Nutt, John G; Ritz, Beate; Samii, Ali; Tanner, Caroline M; Van Broeckhoven, Christine; Van Den Eeden, Stephen K; Wirdefeldt, Karin; Zabetian, Cyrus P; Dehem, Marie; Montimurro, Jennifer S; Southwick, Audrey; Myers, Richard M; Trikalinos, Thomas A

    2013-01-01

    Summary Background A genome-wide association study identified 13 single-nucleotide polymorphisms (SNPs) significantly associated with Parkinson’s disease. Small-scale replication studies were largely non-confirmatory, but a meta-analysis that included data from the original study could not exclude all SNP associations, leaving relevance of several markers uncertain. Methods Investigators from three Michael J Fox Foundation for Parkinson’s Research-funded genetics consortia—comprising 14 teams—contributed DNA samples from 5526 patients with Parkinson’s disease and 6682 controls, which were genotyped for the 13 SNPs. Most (88%) participants were of white, non-Hispanic descent. We assessed log-additive genetic effects using fixed and random effects models stratified by team and ethnic origin, and tested for heterogeneity across strata. A meta-analysis was undertaken that incorporated data from the original genome-wide study as well as subsequent replication studies. Findings In fixed and random-effects models no associations with any of the 13 SNPs were identified (odds ratios 0·89 to 1·09). Heterogeneity between studies and between ethnic groups was low for all SNPs. Subgroup analyses by age at study entry, ethnic origin, sex, and family history did not show any consistent associations. In our meta-analysis, no SNP showed significant association (summary odds ratios 0·95 to 1.08); there was little heterogeneity except for SNP rs7520966. Interpretation Our results do not lend support to the finding that the 13 SNPs reported in the original genome-wide association study are genetic susceptibility factors for Parkinson’s disease. PMID:17052658

  17. Communication: An improved linear scaling perturbative triples correction for the domain based local pair-natural orbital based singles and doubles coupled cluster method [DLPNO-CCSD(T)

    KAUST Repository

    Guo, Yang

    2018-01-04

    In this communication, an improved perturbative triples correction (T) algorithm for domain based local pair-natural orbital singles and doubles coupled cluster (DLPNO-CCSD) theory is reported. In our previous implementation, the semi-canonical approximation was used and linear scaling was achieved for both the DLPNO-CCSD and (T) parts of the calculation. In this work, we refer to this previous method as DLPNO-CCSD(T0) to emphasize the semi-canonical approximation. It is well-established that the DLPNO-CCSD method can predict very accurate absolute and relative energies with respect to the parent canonical CCSD method. However, the (T0) approximation may introduce significant errors in absolute energies as the triples correction grows up in magnitude. In the majority of cases, the relative energies from (T0) are as accurate as the canonical (T) results of themselves. Unfortunately, in rare cases and in particular for small gap systems, the (T0) approximation breaks down and relative energies show large deviations from the parent canonical CCSD(T) results. To address this problem, an iterative (T) algorithm based on the previous DLPNO-CCSD(T0) algorithm has been implemented [abbreviated here as DLPNO-CCSD(T)]. Using triples natural orbitals to represent the virtual spaces for triples amplitudes, storage bottlenecks are avoided. Various carefully designed approximations ease the computational burden such that overall, the increase in the DLPNO-(T) calculation time over DLPNO-(T0) only amounts to a factor of about two (depending on the basis set). Benchmark calculations for the GMTKN30 database show that compared to DLPNO-CCSD(T0), the errors in absolute energies are greatly reduced and relative energies are moderately improved. The particularly problematic case of cumulene chains of increasing lengths is also successfully addressed by DLPNO-CCSD(T).

  18. Communication: An improved linear scaling perturbative triples correction for the domain based local pair-natural orbital based singles and doubles coupled cluster method [DLPNO-CCSD(T)

    KAUST Repository

    Guo, Yang; Riplinger, Christoph; Becker, Ute; Liakos, Dimitrios G.; Minenkov, Yury; Cavallo, Luigi; Neese, Frank

    2018-01-01

    In this communication, an improved perturbative triples correction (T) algorithm for domain based local pair-natural orbital singles and doubles coupled cluster (DLPNO-CCSD) theory is reported. In our previous implementation, the semi-canonical approximation was used and linear scaling was achieved for both the DLPNO-CCSD and (T) parts of the calculation. In this work, we refer to this previous method as DLPNO-CCSD(T0) to emphasize the semi-canonical approximation. It is well-established that the DLPNO-CCSD method can predict very accurate absolute and relative energies with respect to the parent canonical CCSD method. However, the (T0) approximation may introduce significant errors in absolute energies as the triples correction grows up in magnitude. In the majority of cases, the relative energies from (T0) are as accurate as the canonical (T) results of themselves. Unfortunately, in rare cases and in particular for small gap systems, the (T0) approximation breaks down and relative energies show large deviations from the parent canonical CCSD(T) results. To address this problem, an iterative (T) algorithm based on the previous DLPNO-CCSD(T0) algorithm has been implemented [abbreviated here as DLPNO-CCSD(T)]. Using triples natural orbitals to represent the virtual spaces for triples amplitudes, storage bottlenecks are avoided. Various carefully designed approximations ease the computational burden such that overall, the increase in the DLPNO-(T) calculation time over DLPNO-(T0) only amounts to a factor of about two (depending on the basis set). Benchmark calculations for the GMTKN30 database show that compared to DLPNO-CCSD(T0), the errors in absolute energies are greatly reduced and relative energies are moderately improved. The particularly problematic case of cumulene chains of increasing lengths is also successfully addressed by DLPNO-CCSD(T).

  19. Sentinel node biopsy before neoadjuvant chemotherapy spares breast cancer patients axillary lymph node dissection

    NARCIS (Netherlands)

    van Rijk, Maartje C.; Nieweg, Omgo E.; Rutgers, Emiel J. T.; Oldenburg, Hester S. A.; Valdés Olmos, Renato; Hoefnagel, Cornelis A.; Kroon, Bin B. R.

    2006-01-01

    BACKGROUND: Neoadjuvant chemotherapy in breast cancer patients is a valuable method to determine the efficacy of chemotherapy and potentially downsize the primary tumor, which facilitates breast-conserving therapy. In 18 studies published about sentinel node biopsy after neoadjuvant chemotherapy,

  20. A characterization of scale invariant responses in enzymatic networks.

    Directory of Open Access Journals (Sweden)

    Maja Skataric

    Full Text Available An ubiquitous property of biological sensory systems is adaptation: a step increase in stimulus triggers an initial change in a biochemical or physiological response, followed by a more gradual relaxation toward a basal, pre-stimulus level. Adaptation helps maintain essential variables within acceptable bounds and allows organisms to readjust themselves to an optimum and non-saturating sensitivity range when faced with a prolonged change in their environment. Recently, it was shown theoretically and experimentally that many adapting systems, both at the organism and single-cell level, enjoy a remarkable additional feature: scale invariance, meaning that the initial, transient behavior remains (approximately the same even when the background signal level is scaled. In this work, we set out to investigate under what conditions a broadly used model of biochemical enzymatic networks will exhibit scale-invariant behavior. An exhaustive computational study led us to discover a new property of surprising simplicity and generality, uniform linearizations with fast output (ULFO, whose validity we show is both necessary and sufficient for scale invariance of three-node enzymatic networks (and sufficient for any number of nodes. Based on this study, we go on to develop a mathematical explanation of how ULFO results in scale invariance. Our work provides a surprisingly consistent, simple, and general framework for understanding this phenomenon, and results in concrete experimental predictions.

  1. A novel communication mechanism based on node potential multi-path routing

    Science.gov (United States)

    Bu, Youjun; Zhang, Chuanhao; Jiang, YiMing; Zhang, Zhen

    2016-10-01

    With the network scales rapidly and new network applications emerge frequently, bandwidth supply for today's Internet could not catch up with the rapid increasing requirements. Unfortunately, irrational using of network sources makes things worse. Actual network deploys single-next-hop optimization paths for data transmission, but such "best effort" model leads to the imbalance use of network resources and usually leads to local congestion. On the other hand Multi-path routing can use the aggregation bandwidth of multi paths efficiently and improve the robustness of network, security, load balancing and quality of service. As a result, multi-path has attracted much attention in the routing and switching research fields and many important ideas and solutions have been proposed. This paper focuses on implementing the parallel transmission of multi next-hop data, balancing the network traffic and reducing the congestion. It aimed at exploring the key technologies of the multi-path communication network, which could provide a feasible academic support for subsequent applications of multi-path communication networking. It proposed a novel multi-path algorithm based on node potential in the network. And the algorithm can fully use of the network link resource and effectively balance network link resource utilization.

  2. Thermoelectric energy harvesting system for demonstrating autonomous operation of a wireless sensor node enabled by a multipurpose interface

    International Nuclear Information System (INIS)

    Leicht, Joachim; Heilmann, Peter; Maurath, Dominic; Moranz, Christian; Manoli, Yiannos; Hehn, Thorsten; Li, Xiaoming; Thewes, Marcell; Scholl, Gerd

    2013-01-01

    This paper demonstrates the autonomous operation of a wireless sensor node exclusively powered by thermoelectric energy harvesting. Active operation of a wireless sensor system is demonstrated successfully by means of an on-line programmable emulation kit that enables various thermoelectric energy harvesting scenarios. Moreover, this emulation kit accomplishes autonomous wireless sensor node operation by interfacing a small-scaled thermogenerator via a CMOS integrated autonomous multipurpose energy harvesting interface circuit performing maximum power point tracking

  3. Improved Relay Node Placement Algorithm for Wireless Sensor Networks Application in Wind Farm

    DEFF Research Database (Denmark)

    Chen, Qinyin; Hu, Y.; Chen, Zhe

    2013-01-01

    -tolerance. Each wind turbine has a potentially large number of data points needing to be monitored and collected, as farms continue to increase in scale; distances between turbines can reach several hundred meters. Optimal placement of relays in a large farm requires an efficient algorithmic solution. A relay...... node placement algorithm is proposed in this paper to approximate the optimal position for relays connecting each turbine. However, constraints are then required to prevent relay nodes being overloaded in 3-dimensions. The algorithm is extended to 3-dimensional Euclidean space for this optimal relay...

  4. Hub nodes inhibit the outbreak of epidemic under voluntary vaccination

    Energy Technology Data Exchange (ETDEWEB)

    Zhang Haifeng; Wang Binghong [Department of Modern Physics, University of Science and Technology of China, Hefei 230026 (China)], E-mail: bhwang@ustc.edu.cn; Zhang Jie; Small, Michael [Department of Electronic and Information Engineering, Hong Kong Polytechnic University, Hung Hom, Kowloon, Hong Kong (China)], E-mail: ensmall@polyu.edu.hk; Zhou Changsong [Department of Physics, Centre for Nonlinear Studies, and Beijing-Hong Kong-Singapore Joint Centre for Nonlinear and Complex Systems (Hong Kong), Hong Kong Baptist University, Kowloon Tong, Hong Kong (China)

    2010-02-15

    It is commonly believed that epidemic spreading on scale-free networks is difficult to control and that the disease can spread even with a low infection rate, lacking an epidemic threshold. In this paper, we study epidemic spreading on complex networks under the framework of game theory, in which a voluntary vaccination strategy is incorporated. In particular, individuals face the 'dilemma' of vaccination: they have to decide whether or not to vaccinate according to the trade-off between the risk and the side effects or cost of vaccination. Remarkably and quite excitingly, we find that disease outbreak can be more effectively inhibited on scale-free networks than on random networks. This is because the hub nodes of scale-free networks are more inclined to take self-vaccination after balancing the pros and cons. This result is encouraging as it indicates that real-world networks, which are often claimed to be scale free, can be favorably and easily controlled under voluntary vaccination. Our work provides a way of understanding how to prevent the outbreak of diseases under voluntary vaccination, and is expected to provide valuable information on effective disease control and appropriate decision-making.

  5. Hub nodes inhibit the outbreak of epidemic under voluntary vaccination

    International Nuclear Information System (INIS)

    Zhang Haifeng; Wang Binghong; Zhang Jie; Small, Michael; Zhou Changsong

    2010-01-01

    It is commonly believed that epidemic spreading on scale-free networks is difficult to control and that the disease can spread even with a low infection rate, lacking an epidemic threshold. In this paper, we study epidemic spreading on complex networks under the framework of game theory, in which a voluntary vaccination strategy is incorporated. In particular, individuals face the 'dilemma' of vaccination: they have to decide whether or not to vaccinate according to the trade-off between the risk and the side effects or cost of vaccination. Remarkably and quite excitingly, we find that disease outbreak can be more effectively inhibited on scale-free networks than on random networks. This is because the hub nodes of scale-free networks are more inclined to take self-vaccination after balancing the pros and cons. This result is encouraging as it indicates that real-world networks, which are often claimed to be scale free, can be favorably and easily controlled under voluntary vaccination. Our work provides a way of understanding how to prevent the outbreak of diseases under voluntary vaccination, and is expected to provide valuable information on effective disease control and appropriate decision-making.

  6. Node clustering for wireless sensor networks

    International Nuclear Information System (INIS)

    Bhatti, S.; Qureshi, I.A.; Memon, S.

    2012-01-01

    Recent years have witnessed considerable growth in the development and deployment of clustering methods which are not only used to maintain network resources but also increases the reliability of the WSNs (Wireless Sensor Network) and the facts manifest by the wide range of clustering solutions. Node clustering by selecting key parameters to tackle the dynamic behaviour of resource constraint WSN is a challenging issue. This paper highlights the recent progress which has been carried out pertaining to the development of clustering solutions for the WSNs. The paper presents classification of node clustering methods and their comparison based on the objectives, clustering criteria and methodology. In addition, the potential open issues which need to be considered for future work are high lighted. Keywords: Clustering, Sensor Network, Static, Dynamic

  7. Source and sink nodes in absence seizures.

    Science.gov (United States)

    Rodrigues, Abner C; Machado, Birajara S; Caboclo, Luis Otavio S F; Fujita, Andre; Baccala, Luiz A; Sameshima, Koichi

    2016-08-01

    As opposed to focal epilepsy, absence seizures do not exhibit a clear seizure onset zone or focus since its ictal activity rapidly engages both brain hemispheres. Yet recent graph theoretical analysis applied to absence seizures EEG suggests the cortical focal presence, an unexpected feature for this type of epilepsy. In this study, we explore the characteristics of absence seizure by classifying the nodes as to their source/sink natures via weighted directed graph analysis based on connectivity direction and strength estimation using information partial directed coherence (iPDC). By segmenting the EEG signals into relatively short 5-sec-long time windows we studied the evolution of coupling strengths from both sink and source nodes, and the network dynamics of absence seizures in eight patients.

  8. Primary lymph node responses to mosquito bites.

    Science.gov (United States)

    Mellink, J J; Vos, B J

    1977-03-29

    Post-auricular lymph node responses and changes in fresh weight of thymus and spleen of hamsters and mice at 4 and 8 days after primary exposure of both ears to 20 bites by the mosquito Aedes aegypti were studied quantitatively. In both hosts lymph node changes characteristic of the development of cell-mediated immune responses and those which are believed to lead to antibody production occurred, with the emphasis on the latter phenomena. No reactions of thymus and spleen were observed. The responses recorded are considered to be immunologically specific. In hamsters, but not in mice, the responses related to humoral sensitization coincided in time to a large extent with those of the cell-mediated immune processes. The stronger humoral responses in mice were probably in the first place the result of the relatively higher dosages applied.

  9. Vertical Line Nodes in the Superconducting Gap Structure of Sr_{2}RuO_{4}

    Directory of Open Access Journals (Sweden)

    E. Hassinger

    2017-03-01

    Full Text Available There is strong experimental evidence that the superconductor Sr_{2}RuO_{4} has a chiral p-wave order parameter. This symmetry does not require that the associated gap has nodes, yet specific heat, ultrasound, and thermal conductivity measurements indicate the presence of nodes in the superconducting gap structure of Sr_{2}RuO_{4}. Theoretical scenarios have been proposed to account for the existence of deep minima or accidental nodes (minima tuned to zero or below by material parameters within a p-wave state. Other scenarios propose chiral d-wave and f-wave states, with horizontal and vertical line nodes, respectively. To elucidate the nodal structure of the gap, it is essential to know whether the lines of nodes (or minima are vertical (parallel to the tetragonal c axis or horizontal (perpendicular to the c axis. Here, we report thermal conductivity measurements on single crystals of Sr_{2}RuO_{4} down to 50 mK for currents parallel and perpendicular to the c axis. We find that there is substantial quasiparticle transport in the T=0 limit for both current directions. A magnetic field H immediately excites quasiparticles with velocities both in the basal plane and in the c direction. Our data down to T_{c}/30 and down to H_{c2}/100 show no evidence that the nodes are in fact deep minima. Relative to the normal state, the thermal conductivity of the superconducting state is found to be very similar for the two current directions, from H=0 to H=H_{c2}. These findings show that the gap structure of Sr_{2}RuO_{4} consists of vertical line nodes. This rules out a chiral d-wave state. Given that the c-axis dispersion (warping of the Fermi surface in Sr_{2}RuO_{4} varies strongly from sheet to sheet, the small a-c anisotropy suggests that the line nodes are present on all three sheets of the Fermi surface. If imposed by symmetry, vertical line nodes would be inconsistent with a p-wave order parameter for Sr_{2}RuO_{4}. To reconcile the gap structure

  10. Large-scale single-crystal growth of (CH3)2NH2CuCl3 for neutron scattering experiments

    Science.gov (United States)

    Park, Garam; Oh, In-Hwan; Park, J. M. Sungil; Park, Seong-Hun; Hong, Chang Seop; Lee, Kwang-Sei

    2016-05-01

    Neutron scattering studies on low-dimensional quantum spin systems require large-size single-crystals. Single-crystals of (CH3)2NH2CuCl3 showing low-dimensional magnetic behaviors were grown by a slow solvent evaporation method in a two-solvent system at different temperature settings. The best results were obtained for the bilayer solution of methanol and isopropanol with a molar ratio of 2:1 at 35 °C. The quality of the obtained single-crystals was tested by powder and single-crystal X-ray diffraction and single-crystal neutron diffraction. In addition, to confirm structural phase transitions (SPTs), thermal analysis and single-crystal X-ray diffraction at 300 K and 175 K, respectively, were conducted, confirming the presence of a SPT at Tup=288 K on heating and Tdown=285 K on cooling.

  11. Clinical application of CT-guided percutaneous puncturing biopsy of subcarinal lymph node

    International Nuclear Information System (INIS)

    Yuan Xiaodong; Wang Jianhua; Zuo Changjing; Tian Jianming

    2011-01-01

    Objective: To discuss the safety and clinical significance of CT-guided percutaneous puncturing biopsy of subcarinal lymph node. Methods: During the period of July 2006-July 2010, CT-guided percutaneous puncturing biopsy of subcarinal lymph node was carried out in 17 patients (11 males and 6 females, with an average age of 54 years) with enlarged subcarinal lymph nodes. The clinical data were retrospectively analyzed. Immediately after the puncturing procedure was completed, CT scanning was performed to observe if there any complications and to evaluate the safety of puncturing biopsy. Biopsy specimens were sent for pathological examination to assess the puncturing accuracy and to make the pathologic diagnosis. The clinical usefulness of this technique was evaluated. Results: Of the total 17 cases, successful puncturing into the enlarged subcarinal lymph nodes with single procedure was achieved in 14 and sufficient tissue sample was obtained. The biopsy failed in three cases at initial puncturing procedure as the needle could not be placed into the enlarged subcarinal lymph nodes, the puncturing biopsy had to given up in two patients because of hemoptysis and in another patient the second puncturing biopsy performed one week later was successful. The total technical successful rate was 88.2% (15/17). Of the fifteen cases with successful puncturing, definitive pathological diagnosis was obtained in 13 and the diagnosis was uncertain in the remaining two, with a diagnosis positive rate of 86.7% (13/15). Pathologically, the diagnoses included metastatic lymphadenopathy from lung cancer (n=10), proliferative inflammatory lymphadenopathy (n=2) and tuberculous enlargement of lymph nodes (n=1). Complications occurred in 4 patients (23.5%, 4/17), which mainly were pneumothorax and pulmonary hemorrhage. Conclusion: With high successful rate and diagnostic accuracy, CT-guided percutaneous puncturing biopsy of subcarinal lymph node is a safe and effective technique if the

  12. Concordance between peri-areolar blue dye and peri-incisional radiotracer injections for sentinel node mapping in patients with a history of primary breast cancer excisonal biopsy.

    Science.gov (United States)

    Mehrabibahar, M; Azizi, S; Jangjoo, A; Saremi, E; Kakhki, V R Dabbagh; Sadeghi, R; Chicken, D W; Keshtgar, M

    2014-01-01

    We evaluated the concordance between peri-areolar blue dye and peri-incisional radiotracer injections for axillary sentinel node mapping of patients with the history of previous breast lesion excisional biopsy. 80 patients with the history of previous excisional biopsy of the breast lesions were included. All patients received two injections of 99mTc-antimony sulfide colloid in both ends of incision line in an intradermal fashion. 2 mL patient blue V dye was injection to all patients in the peri-areolar area of the index quadrant after induction of anesthesia. All blue or hot nodes were harvested as sentinel lymph nodes. At least one sentinel node could be detected during surgery in 79 patients. In total 94 sentinel nodes were detected. All detected sentinel nodes were hot. In three patients sentinel nodes were detected by gamma probe but not blue dye. The tumor location in all of these patients was in the upper lateral quadrant and the incision line was extended into the axillary tail of the breast in all of them. 91 out of 94 sentinel nodes were stained blue, which amounts to 95.8% concordance between blue dye and radiotracer on a per node analysis. Single peri-areolar injection in the index quadrant would suffice for sentinel node mapping of patients with history of excisional biopsy. Care should be taken in patients with large excisional biopsy in the extreme proximity to axilla.

  13. Interactive Graph Layout of a Million Nodes

    OpenAIRE

    Peng Mi; Maoyuan Sun; Moeti Masiane; Yong Cao; Chris North

    2016-01-01

    Sensemaking of large graphs, specifically those with millions of nodes, is a crucial task in many fields. Automatic graph layout algorithms, augmented with real-time human-in-the-loop interaction, can potentially support sensemaking of large graphs. However, designing interactive algorithms to achieve this is challenging. In this paper, we tackle the scalability problem of interactive layout of large graphs, and contribute a new GPU-based force-directed layout algorithm that exploits